WorldWideScience

Sample records for cost combined systems

  1. Combined Waste Form Cost Trade Study

    International Nuclear Information System (INIS)

    Gombert, Dirk; Piet, Steve; Trickel, Timothy; Carter, Joe; Vienna, John; Ebert, Bill; Matthern, Gretchen

    2008-01-01

    A new generation of aqueous nuclear fuel reprocessing, now in development under the auspices of the DOE Office of Nuclear Energy (NE), separates fuel into several fractions, thereby partitioning the wastes into groups of common chemistry. This technology advance enables development of waste management strategies that were not conceivable with simple PUREX reprocessing. Conventional wisdom suggests minimizing high level waste (HLW) volume is desirable, but logical extrapolation of this concept suggests that at some point the cost of reducing volume further will reach a point of diminishing return and may cease to be cost-effective. This report summarizes an evaluation considering three groupings of wastes in terms of cost-benefit for the reprocessing system. Internationally, the typical waste form for HLW from the PUREX process is borosilicate glass containing waste elements as oxides. Unfortunately several fission products (primarily Mo and the noble metals Ru, Rh, Pd) have limited solubility in glass, yielding relatively low waste loading, producing more glass, and greater disposal costs. Advanced separations allow matching the waste form to waste stream chemistry, allowing the disposal system to achieve more optimum waste loading with improved performance. Metals can be segregated from oxides and each can be stabilized in forms to minimize the HLW volume for repository disposal. Thus, a more efficient waste management system making the most effective use of advanced waste forms and disposal design for each waste is enabled by advanced separations and how the waste streams are combined. This trade-study was designed to juxtapose a combined waste form baseline waste treatment scheme with two options and to evaluate the cost-benefit using available data from the conceptual design studies supported by DOE-NE

  2. Security cost allocation under combined bilateral-pool market dispatch

    International Nuclear Information System (INIS)

    Abdullah, M.P.; Hassan, M.Y.; Hussin, F.

    2008-01-01

    Most electricity markets around the world are a combination of bilateral and pool markets, such as NordPool and NYPOOL. In these models, market participants bid into the pool and also make bilateral contracts with each other. This paper addressed the issue of congestion management and security cost allocation in a power pool market model. The basic idea of security cost allocation is to divide the incurred security cost due to congestion relief into pool and bilateral market based on their flow contribution to the congested line. A newly proposed security cost allocation strategy of the combined bilateral-pool market was also presented along with case studies using IEEE-14 bus system that tested the proposed method. Using the proposed method, it was shown that security costs are allocated to market participants at different prices which reflect the load contribution to the security problem. This solves the problem of the uniform security cost allocation in a pure pool market system having uniform pricing, and provides a proper security signal to market participants. 11 refs., 3 tabs., 4 figs

  3. Synergistic Role of Balanced Scorecard/Activity Based Costing and Goal Programming Combined Model on Strategic Cost Management

    OpenAIRE

    Taleghani, Mohammad

    2017-01-01

    During the past few years, we have seen a significant shift in cost accounting and management. In the new business environment, cost management has become a critical skill, but it is not sufficient for simply reducing costs; instead, costs must be managed strategically. Application of a successful Strategic Cost Management (StraCM) system plays the significant role in success of organization performance. In this study, we want to illustrate how the goal programming model in combination with t...

  4. Cost reduction through system integration

    International Nuclear Information System (INIS)

    Helsing, P.

    1994-01-01

    In resent years cost reduction has been a key issue in the petroleum industry. Several findings are not economically attractive at the current cost level, and for this and other reasons some of the major oil companies require the suppliers to have implemented a cost reduction programme to prequalify for projects. The present paper addresses cost reduction through system design and integration in both product development and working methods. This is to be obtained by the combination of contracts by reducing unnecessary coordination and allow re-use of proven interface designs, improve subsystem integration by ''top down'' system design, and improve communication and exchange of experience. 3 figs

  5. Cost Accounting System for fusion studies

    International Nuclear Information System (INIS)

    Hamilton, W.R.; Keeton, D.C.; Thomson, S.L.

    1985-12-01

    A Cost Accounting System that is applicable to all magnetic fusion reactor design studies has been developed. This system provides: (1) definitions of the elements of cost and methods for the combination of these elements to form a cost estimate; (2) a Code of Accounts that uses a functional arrangement for identification of the plant components; and (3) definitions and methods to analyze actual cost data so that the data can be directly reported into this Cost Accounting System. The purpose of the Cost Accounting System is to provide the structure for the development of a fusion cost data base and for the development of validated cost estimating procedures. This system has been developed through use at the Fusion Engineering Design Center (FEDC) and has been applied to different confinement concepts (tokamaks and tandem mirrors) and to different types of projects (experimental devices and commercial power plants). The use of this Cost Accounting System by all magnetic fusion projects will promote the development of a common cost data base, allow the direct comparison of cost estimates, and ultimately establish the cost credibility of the program

  6. Cost Accounting System for fusion studies

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, W.R.; Keeton, D.C.; Thomson, S.L.

    1985-12-01

    A Cost Accounting System that is applicable to all magnetic fusion reactor design studies has been developed. This system provides: (1) definitions of the elements of cost and methods for the combination of these elements to form a cost estimate; (2) a Code of Accounts that uses a functional arrangement for identification of the plant components; and (3) definitions and methods to analyze actual cost data so that the data can be directly reported into this Cost Accounting System. The purpose of the Cost Accounting System is to provide the structure for the development of a fusion cost data base and for the development of validated cost estimating procedures. This system has been developed through use at the Fusion Engineering Design Center (FEDC) and has been applied to different confinement concepts (tokamaks and tandem mirrors) and to different types of projects (experimental devices and commercial power plants). The use of this Cost Accounting System by all magnetic fusion projects will promote the development of a common cost data base, allow the direct comparison of cost estimates, and ultimately establish the cost credibility of the program.

  7. Cost-effectiveness analysis of combination therapies for visceral leishmaniasis in the Indian subcontinent.

    Directory of Open Access Journals (Sweden)

    Filip Meheus

    2010-09-01

    Full Text Available Visceral leishmaniasis is a systemic parasitic disease that is fatal unless treated. We assessed the cost and cost-effectiveness of alternative strategies for the treatment of visceral leishmaniasis in the Indian subcontinent. In particular we examined whether combination therapies are a cost-effective alternative compared to monotherapies.We assessed the cost-effectiveness of all possible mono- and combination therapies for the treatment of visceral leishmaniasis in the Indian subcontinent (India, Nepal and Bangladesh from a societal perspective using a decision analytical model based on a decision tree. Primary data collected in each country was combined with data from the literature and an expert poll (Delphi method. The cost per patient treated and average and incremental cost-effectiveness ratios expressed as cost per death averted were calculated. Extensive sensitivity analysis was done to evaluate the robustness of our estimations and conclusions. With a cost of US$92 per death averted, the combination miltefosine-paromomycin was the most cost-effective treatment strategy. The next best alternative was a combination of liposomal amphotericin B with paromomycin with an incremental cost-effectiveness of $652 per death averted. All other strategies were dominated with the exception of a single dose of 10mg per kg of liposomal amphotericin B. While strategies based on liposomal amphotericin B (AmBisome were found to be the most effective, its current drug cost of US$20 per vial resulted in a higher average cost-effectiveness. Sensitivity analysis showed the conclusion to be robust to variations in the input parameters over their plausible range.Combination treatments are a cost-effective alternative to current monotherapy for VL. Given their expected impact on the emergence of drug resistance, a switch to combination therapy should be considered once final results from clinical trials are available.

  8. Cost-effectiveness Analysis of Antipsychotic Combination Therapy in Schizophrenia Inpatients

    Directory of Open Access Journals (Sweden)

    Rizky Abdulah

    2017-03-01

    Full Text Available Schizophrenia is one of mental disorders with high cost and lifetime morbidity risk. Hence, it is necessary to analyze the cost-effectiveness of various combinations of antipsychotics. The aim of this study was to analyze the most cost-effective group of antipsychotic combinations in schizophrenia inpatients in West Java Psychiatric Hospital during 2012–2013. Data were collected retrospectively from medical record of patients who used antipsychotics clozapine-haloperidol or clozapine-risperidone therapy. Direct medical costs were obtained from antipsychotics costs, costs of medical treatment, medical expenses, hospitalization costs, and administrative costs. The results showed that the average cost-effectiveness ratio of antipsychotic clozapine-haloperidol was Rp126.898/day and Rp132.781/day for the combination of clozapine-haloperidol and clozapine-risperidone, respectively. Considering length of stay as the therapy effectiveness, it can be concluded that the combination of clozapine-haloperidol is more cost-effective than clozapine-risperidone.

  9. Combining loss and cost objectives in daily hydro-thermal economic scheduling

    International Nuclear Information System (INIS)

    El-Hawary, M.E.; Ravindranath, K.M.

    1991-01-01

    A formulation of optimal hydro-thermal power flow in electric power systems combining the minimum loss objective with the more conventional minimum fuel cost objective is considered. The implementation is based on a Newton's iterative procedure, with special initial guess and sparsity-based matrix manipulations to obtain improved convergence properties. The strategies are developed using three standard test systems. This paper discusses the question of assigning an equivalent cost to the loss objective component and compare results obtained using two proposed mechanisms. The first is based on results of conventional dispatch using Kron's loss formula and the second uses the bus incremental costs involved in the OPF solution. The effects of varying the relative weights assigned to each objective component on pertinent system variables such as active and reactive power generations as well as voltages are explored

  10. Factors affecting economies of scale in combined sewer systems.

    Science.gov (United States)

    Maurer, Max; Wolfram, Martin; Anja, Herlyn

    2010-01-01

    A generic model is introduced that represents the combined sewer infrastructure of a settlement quantitatively. A catchment area module first calculates the length and size distribution of the required sewer pipes on the basis of rain patterns, housing densities and area size. These results are fed into the sewer-cost module in order to estimate the combined sewer costs of the entire catchment area. A detailed analysis of the relevant input parameters for Swiss settlements is used to identify the influence of size on costs. The simulation results confirm that an economy of scale exists for combined sewer systems. This is the result of two main opposing cost factors: (i) increased construction costs for larger sewer systems due to larger pipes and increased rain runoff in larger settlements, and (ii) lower costs due to higher population and building densities in larger towns. In Switzerland, the more or less organically grown settlement structures and limited land availability emphasise the second factor to show an apparent economy of scale. This modelling approach proved to be a powerful tool for understanding the underlying factors affecting the cost structure for water infrastructures.

  11. Low Cost Integrated Navigation System for Unmanned Vessel

    Directory of Open Access Journals (Sweden)

    Yang Changsong

    2017-11-01

    Full Text Available Large errors of low-cost MEMS inertial measurement unit (MIMU lead to huge navigation errors, even wrong navigation information. An integrated navigation system for unmanned vessel is proposed. It consists of a low-cost MIMU and Doppler velocity sonar (DVS. This paper presents an integrated navigation method, to improve the performance of navigation system. The integrated navigation system is tested using simulation and semi-physical simulation experiments, whose results show that attitude, velocity and position accuracy has improved awfully, giving exactly accurate navigation results. By means of the combination of low-cost MIMU and DVS, the proposed system is able to overcome fast drift problems of the low cost IMU.

  12. [Cost of therapy for neurodegenerative diseases. Applying an activity-based costing system].

    Science.gov (United States)

    Sánchez-Rebull, María-Victoria; Terceño Gómez, Antonio; Travé Bautista, Angeles

    2013-01-01

    To apply the activity based costing (ABC) model to calculate the cost of therapy for neurodegenerative disorders in order to improve hospital management and allocate resources more efficiently. We used the case study method in the Francolí long-term care day center. We applied all phases of an ABC system to quantify the cost of the activities developed in the center. We identified 60 activities; the information was collected in June 2009. The ABC system allowed us to calculate the average cost per patient with respect to the therapies received. The most costly and commonly applied technique was psycho-stimulation therapy. Focusing on this therapy and on others related to the admissions process could lead to significant cost savings. ABC costing is a viable method for costing activities and therapies in long-term day care centers because it can be adapted to their structure and standard practice. This type of costing allows the costs of each activity and therapy, or combination of therapies, to be determined and aids measures to improve management. Copyright © 2012 SESPAS. Published by Elsevier Espana. All rights reserved.

  13. Computer aided system for parametric design of combination die

    Science.gov (United States)

    Naranje, Vishal G.; Hussein, H. M. A.; Kumar, S.

    2017-09-01

    In this paper, a computer aided system for parametric design of combination dies is presented. The system is developed using knowledge based system technique of artificial intelligence. The system is capable to design combination dies for production of sheet metal parts having punching and cupping operations. The system is coded in Visual Basic and interfaced with AutoCAD software. The low cost of the proposed system will help die designers of small and medium scale sheet metal industries for design of combination dies for similar type of products. The proposed system is capable to reduce design time and efforts of die designers for design of combination dies.

  14. Exergy costing for energy saving in combined heating and cooling applications

    International Nuclear Information System (INIS)

    Nguyen, Chan; Veje, Christian T.; Willatzen, Morten; Andersen, Peer

    2014-01-01

    Highlights: • We investigate the basis for cost apportioning of simultaneous heating and cooling. • Two thermoeconomic methods based on energy and exergy costing is demonstrated. • The unit cost of heating and cooling for a heat pump system is found and compared. • Energy costing may obstruct efficient use of energy. • Exergy costing provides the most rational cost apportioning for energy saving. - Abstract: The aim of this study is to provide a price model that motivates energy saving for a combined district heating and cooling system. A novel analysis using two thermoeconomic methods for apportioning the costs to heating and cooling provided simultaneously by an ammonia heat pump is demonstrated. In the first method, referred to as energy costing, a conventional thermoeconomic analysis is used. Here the ammonia heat pump is subject to a thermodynamic analysis with mass and energy balance equations. In the second method referred to as exergy costing, an exergy based economic analysis is used, where exergy balance equations are used in conjunction with mass and energy balance equations. In both costing methods the thermodynamic analysis is followed by an economic analysis which includes investment and operating costs. For both methods the unit costs of heating and cooling are found and compared. The analysis shows that the two methods yield significantly different results. Rather surprisingly, it is demonstrated that the exergy costing method results in about three times higher unit cost for heating than for cooling as opposed to equal unit costs when using the energy method. Further the exergy-based cost for heating changes considerably with the heating temperature while that of cooling is much less affected

  15. Cost allocation. Combined heat and power production

    International Nuclear Information System (INIS)

    Sidzikauskas, V.

    2002-01-01

    The benefits of Combined Heat and Power (CHP) generation are discussed. The include improvement in energy intensity of 1% by 2010, 85-90% efficiency versus 40-50% of condensation power and others. Share of CHP electricity production in ERRA countries is presented.Solutions for a development CHP cost allocation are considered. Conclusion are presented for CHP production cost allocation. (R.P.)

  16. A Decision Tool that Combines Discrete Event Software Process Models with System Dynamics Pieces for Software Development Cost Estimation and Analysis

    Science.gov (United States)

    Mizell, Carolyn Barrett; Malone, Linda

    2007-01-01

    The development process for a large software development project is very complex and dependent on many variables that are dynamic and interrelated. Factors such as size, productivity and defect injection rates will have substantial impact on the project in terms of cost and schedule. These factors can be affected by the intricacies of the process itself as well as human behavior because the process is very labor intensive. The complex nature of the development process can be investigated with software development process models that utilize discrete event simulation to analyze the effects of process changes. The organizational environment and its effects on the workforce can be analyzed with system dynamics that utilizes continuous simulation. Each has unique strengths and the benefits of both types can be exploited by combining a system dynamics model and a discrete event process model. This paper will demonstrate how the two types of models can be combined to investigate the impacts of human resource interactions on productivity and ultimately on cost and schedule.

  17. The Potential of Combined Heat and Power Generation, Wind Power Generation and Load Management Techniques for Cost Reduction in Small Electricity Supply Systems.

    Science.gov (United States)

    Bass, Jeremy Hugh

    Available from UMI in association with The British Library. Requires signed TDF. An evaluation is made of the potential fuel and financial savings possible when a small, autonomous diesel system sized to meet the demands of an individual, domestic consumer is adapted to include: (1) combined heat and power (CHP) generation, (2) wind turbine generation, (3) direct load control. The potential of these three areas is investigated by means of time-step simulation modelling on a microcomputer. Models are used to evaluate performance and a Net Present Value analysis used to assess costs. A cost/benefit analysis then enables those areas, or combination of areas, that facilitate and greatest savings to be identified. The modelling work is supported by experience gained from the following: (1) field study of the Lundy Island wind/diesel system, (2) laboratory testing of a small diesel generator set, (3) study of a diesel based CHP unit, (4) study of a diesel based direct load control system, (5) statistical analysis of data obtained from the long-term monitoring of a large number of individual household's electricity consumption. Rather than consider the consumer's electrical demand in isolation, a more flexible approach is adopted, with consumer demand being regarded as the sum of primarily two components: a small, electricity demand for essential services and a large, reschedulable demand for heating/cooling. The results of the study indicate that: (1) operating a diesel set in a CHP mode is the best strategy for both financial and fuel savings. A simple retrofit enables overall conversion efficiencies to be increased from 25% to 60%, or greater, at little cost. (2) wind turbine generation in association with direct load control is a most effective combination. (3) a combination of both the above areas enables greatest overall financial savings, in favourable winds resulting in unit energy costs around 20% of those of diesel only operation.

  18. The Launch Systems Operations Cost Model

    Science.gov (United States)

    Prince, Frank A.; Hamaker, Joseph W. (Technical Monitor)

    2001-01-01

    One of NASA's primary missions is to reduce the cost of access to space while simultaneously increasing safety. A key component, and one of the least understood, is the recurring operations and support cost for reusable launch systems. In order to predict these costs, NASA, under the leadership of the Independent Program Assessment Office (IPAO), has commissioned the development of a Launch Systems Operations Cost Model (LSOCM). LSOCM is a tool to predict the operations & support (O&S) cost of new and modified reusable (and partially reusable) launch systems. The requirements are to predict the non-recurring cost for the ground infrastructure and the recurring cost of maintaining that infrastructure, performing vehicle logistics, and performing the O&S actions to return the vehicle to flight. In addition, the model must estimate the time required to cycle the vehicle through all of the ground processing activities. The current version of LSOCM is an amalgamation of existing tools, leveraging our understanding of shuttle operations cost with a means of predicting how the maintenance burden will change as the vehicle becomes more aircraft like. The use of the Conceptual Operations Manpower Estimating Tool/Operations Cost Model (COMET/OCM) provides a solid point of departure based on shuttle and expendable launch vehicle (ELV) experience. The incorporation of the Reliability and Maintainability Analysis Tool (RMAT) as expressed by a set of response surface model equations gives a method for estimating how changing launch system characteristics affects cost and cycle time as compared to today's shuttle system. Plans are being made to improve the model. The development team will be spending the next few months devising a structured methodology that will enable verified and validated algorithms to give accurate cost estimates. To assist in this endeavor the LSOCM team is part of an Agency wide effort to combine resources with other cost and operations professionals to

  19. Using data from monitoring combined sewer overflows to assess, improve, and maintain combined sewer systems

    OpenAIRE

    Montserrat Royuela, Albert; Bosch, Ll.; Kiser, M.A.; Poch, Manuel; Corominas Tabares, Lluís

    2015-01-01

    Using low-cost sensors, data can be collected on the occurrence and duration of overflows in each combined sewer overflow (CSO) structure in a combined sewer system (CSS). The collection and analysis of real data can be used to assess, improve, and maintain CSSs in order to reduce the number and impact of overflows. The objective of this study was to develop a methodology to evaluate the performance of CSSs using low-cost monitoring. This methodology includes (1) assessing the capacity of a C...

  20. Economical Efficiency of Combined Cooling Heating and Power Systems Based on an Enthalpy Method

    Directory of Open Access Journals (Sweden)

    Yan Xu

    2017-11-01

    Full Text Available As the living standards of Chinese people have been improving, the energy demand for cooling and heating, mainly in the form of electricity, has also expanded. Since an integrated cooling, heating and power supply system (CCHP will serve this demand better, the government is now attaching more importance to the application of CCHP energy systems. Based on the characteristics of the combined cooling heating and power supply system, and the method of levelized cost of energy, two calculation methods for the evaluation of the economical efficiency of the system are employed when the energy production in the system is dealt with from the perspective of exergy. According to the first method, fuel costs account for about 75% of the total cost. In the second method, the profits from heating and cooling are converted to fuel costs, resulting in a significant reduction of fuel costs, accounting for 60% of the total cost. Then the heating and cooling parameters of gas turbine exhaust, heat recovery boiler, lithium-bromide heat-cooler and commercial tariff of provincial capitals were set as benchmark based on geographic differences among provinces, and the economical efficiency of combined cooling heating and power systems in each province were evaluated. The results shows that the combined cooling heating and power system is economical in the developed areas of central and eastern China, especially in Hubei and Zhejiang provinces, while in other regions it is not. The sensitivity analysis was also made on related influencing factors of fuel cost, demand intensity in heating and cooling energy, and bank loans ratio. The analysis shows that the levelized cost of energy of combined cooling heating and power systems is very sensitive to exergy consumption and fuel costs. When the consumption of heating and cooling energy increases, the unit cost decreases by 0.1 yuan/kWh, and when the on-grid power ratio decreases by 20%, the cost may increase by 0.1 yuan

  1. Impact of the Japanese Diagnosis Procedure Combination-based Payment System on cardiovascular medicine-related costs.

    Science.gov (United States)

    Yasunaga, Hideo; Ide, Hiroo; Imamura, Tomoaki; Ohe, Kazuhiko

    2005-09-01

    In 2003, a lump-sum payment system based on Diagnosis Procedure Combinations (DPC) was introduced to 82 specific function hospitals in Japan. While the US DRG/PPS system is a "per case payment" system, the DPC based payment system adopts a "per day payment." It is generally believed that the Japanese system provides as much of an incentive as the DRG/PPS system to shorten the average length of stay (LOS). We performed an empirical analysis of the effect of LOS shortening on hospital revenue and expenditure under the DPC-based payment system, particularly in cardiovascular diseases. We also point out fundamentally controversial aspects of the current system. A total 109 cases were selected from patients hospitalized at the University of Tokyo Hospital from May to July, 2003 and classified into one of three categories: (1) cardiac catheter interventions, (2) cardiac catheter examinations, and (3) other conservative treatments. We analyzed the changes in profit per day in cases of a reduction in average LOS and an increase in the number of cases. In category (1) profit increased significantly in conjunction with reduced LOS. In category (2) profit increased only minimally. In category (3), profit increased rarely and sometimes decreased. In cases of conservative treatment, profits sometimes decreased because an increase in material costs exceeded the increase in revenue. It therefore became clear that the DPC-based payment system does not decisively provide an economic incentive to reduce LOS in cardiovascular medicine.

  2. ACTIVITY-BASED COSTING DAN SIMULATED ANNEALING UNTUK PENCARIAN RUTE PADA FLEXIBLE MANUFACTURING SYSTEMS

    OpenAIRE

    Gregorius Satia Budhi

    2003-01-01

    Flexible Manufacturing System (FMS) is a manufacturing system that is formed from several Numerical Controlled Machines combine with material handling system, so that different jobs can be worked by different machines sequences. FMS combine the high productivity and flexibility of Transfer Line and Job Shop manufacturing system. In this reasearch, Activity-Based Costing(ABC) approach was used as the weight to search the operation route in the proper machine, so that the total production cost ...

  3. Japanese Cost Accounting Systems - analysis of the cost accounting systems of the Japanese cost accounting standard

    OpenAIRE

    Peter, Winter

    2005-01-01

    This paper aims at providing an insight into Japanese cost accounting. Firstly, the development of cost accounting in Japan is delineated. Subsequently, the cost accounting systems codified in the Japanese cost accounting standard are analysed based on the classification according to Hoitsch/Schmitz. Lastly, a critical appraisal of the cost accounting systems of the Japanese cost accounting standard as well as a comparison to German and American cost accounting systems are conducted.

  4. Cost and primary energy efficiency of small-scale district heating systems

    International Nuclear Information System (INIS)

    Truong, Nguyen Le; Gustavsson, Leif

    2014-01-01

    Highlights: • We analyzed minimum-cost options for small-scale DHSs under different contexts. • District heat production cost increases with reduced DHS scales. • Fewer technical options are suitable for small-scale DHSs. • Systems with combined technologies are less sensitive to changes in fuel prices. - Abstract: Efficient district heat production systems (DHSs) can contribute to achieving environmental targets and energy security for countries that have demands for space and water heating. The optimal options for a DHS vary with the environmental and social-political contexts and the scale of district heat production, which further depends on the size of the community served and the local climatic conditions. In this study, we design a small-scale, minimum-cost DHS that produces approximately 100 GWh heat per year and estimate the yearly production cost and primary energy use of this system. We consider conventional technologies, such as heat-only boilers, electric heat pumps and combined heat and power (CHP) units, as well as emerging technologies, such as biomass-based organic Rankine cycle (BORC) and solar water heating (SWH). We explore how different environmental and social-political situations influence the design of a minimum-cost DHS and consider both proven and potential technologies for small-scale applications. Our calculations are based on the real heat load duration curve for a town in southern Sweden. We find that the district heat production cost increases and that the potential for cogeneration decreases with smaller district heat production systems. Although the selection of technologies for a minimum-cost DHS depends on environmental and social-political contexts, fewer technical options are suitable for small-scale systems. Emerging technologies such as CHP-BORC and SWH improve the efficiency of primary energy use for heat production, but these technologies are more costly than conventional heat-only boilers. However, systems with

  5. Cost/benefit comparison of thermal solar energy systems in Switzerland

    International Nuclear Information System (INIS)

    Suter, J.M.

    1991-10-01

    A comparison is made between thermal solar energy systems of different size for five different applications in the three main climatic zones in Switzerland. Conventional ways of energy conservation are also included in the comparison. A cost/benefit ratio is calculated for each system. The investment is used as a cost indicator whereas the useful solar heat or the conventional energy saving is chosen as benefit. It is shown that the most systems sold today in Switzerland - combined hot water and space heating systems for single family houses - have the poorest cost/benefit ratio among all systems considered in the analysis. Four applications with more favourable cost/benefit ratio are identified. Large systems have generally a better cost/benefit ratio than smaller ones, although the total investment is higher. Photovoltaics is even less favourable than all thermal systems considered. The large scale penetration of technologies with good cost/benefit ratio lies in the public interest. Supporting activities should consider the priority set by the cost/benefit ratio. (author) 1 fig., 14 refs

  6. Cost Comparison of Conventional Gray Combined Sewer Overflow Control Infrastructure versus a Green/Gray Combination

    Science.gov (United States)

    This paper outlines a life-cycle cost analysis comparing a green (rain gardens) and gray (tunnels) infrastructure combination to a gray-only option to control combined sewer overflow in the Turkey Creek Combined Sewer Overflow Basin, in Kansas City, MO. The plan area of this Bas...

  7. Cost of photovoltaic energy systems as determined by balance-of-system costs

    Science.gov (United States)

    Rosenblum, L.

    1978-01-01

    The effect of the balance-of-system (BOS), i.e., the total system less the modules, on photo-voltaic energy system costs is discussed for multikilowatt, flat-plate systems. Present BOS costs are in the range of 10 to 16 dollars per peak watt (1978 dollars). BOS costs represent approximately 50% of total system cost. The possibility of future BOS cost reduction is examined. It is concluded that, given the nature of BOS costs and the lack of comprehensive national effort focussed on cost reduction, it is unlikely that BOS costs will decline greatly in the next several years. This prognosis is contrasted with the expectations of the Department of Energy National Photovoltaic Program goals and pending legislation in the Congress which require a BOS cost reduction of an order of magnitude or more by the mid-1980s.

  8. System cuts radwaste-disposal cost

    International Nuclear Information System (INIS)

    May, J.R.

    1978-01-01

    Pilot-plant and full-scale prototype-system test data on a new volume-reduction system for low-level radioactive wastes, of the type generated by nuclear plants, indicate that total present costs for radwaste disposal can be reduced by more than 50%. In 1975, Newport News Industrial Corp. and Energy Inc. decided to develop cooperatively a fluidized-bed process that would combine the features of a calciner and an incinerator. The new radwaste-volume-reduction system, designated RWR-1, can reduce the volume of concentrated liquids, ion-exchange resin beads, filter sludges, and various combustible solids, such as protective clothing, rags, paper, wood, and plastics

  9. Cost-utility and cost-effectiveness studies of telemedicine, electronic, and mobile health systems in the literature: a systematic review.

    Science.gov (United States)

    de la Torre-Díez, Isabel; López-Coronado, Miguel; Vaca, Cesar; Aguado, Jesús Saez; de Castro, Carlos

    2015-02-01

    A systematic review of cost-utility and cost-effectiveness research works of telemedicine, electronic health (e-health), and mobile health (m-health) systems in the literature is presented. Academic databases and systems such as PubMed, Scopus, ISI Web of Science, and IEEE Xplore were searched, using different combinations of terms such as "cost-utility" OR "cost utility" AND "telemedicine," "cost-effectiveness" OR "cost effectiveness" AND "mobile health," etc. In the articles searched, there were no limitations in the publication date. The search identified 35 relevant works. Many of the articles were reviews of different studies. Seventy-nine percent concerned the cost-effectiveness of telemedicine systems in different specialties such as teleophthalmology, telecardiology, teledermatology, etc. More articles were found between 2000 and 2013. Cost-utility studies were done only for telemedicine systems. There are few cost-utility and cost-effectiveness studies for e-health and m-health systems in the literature. Some cost-effectiveness studies demonstrate that telemedicine can reduce the costs, but not all. Among the main limitations of the economic evaluations of telemedicine systems are the lack of randomized control trials, small sample sizes, and the absence of quality data and appropriate measures.

  10. Open Drainage and Detention Basin Combined System Optimization

    Directory of Open Access Journals (Sweden)

    M. E. Banihabib

    2017-01-01

    basin and the narrower valley. After the initial selection of dam sites, based on the reservoir volume to construction volume ratio of each dam site, best sites were selected to have the higher ratio. The layout of the main drainage scheme that is responsible for collecting and transferring overland flows of farmlands and reservoir outflows was designed. In order to simulate the hydrological processes in upstream watershed and flood analysis, HEC-HMS model which is an extended version of HEC-1 was used as hydrologic model. The optimal combination of open drainages and detention basins was also developed. Watershed in terms of detention basin dams, topography and drainage were divided into 19 smaller sub-basins. The downstream agricultural basin due to the slope and drainage area was divided into 27 sub-basins. Regarding available information of the watershed, SCS method was used to calculate losses and to convert rainfall to runoff hydrograph. In this section Muskingum flood routing method was used considering its accuracy. In the present optimization model, the total cost of the combined system of dams and open drains used as the objective function. It is function bottom outlet diameter which is minimized by using optimization model. Other factors of the simulation model such as dam height and drainage dimensions were defined as function of the diameter of the bottom outlet of dams. After determining the optimal dimensions of the combined system of open drainage and detention basins, a sensitivity analysis was performed on hydrological factors. Results and Discussion: After optimization of the dimensions of open drainage and detention basin integrated-system, sensitivity analysis was carried out on the dimensions of system for variation of flood simulation parameters such as rainfall, curve number and lag time. The error of estimated rainfall effected far less than the curve number (CN on the optimum dimensions and cost. 10% variation of the rainfall depth caused

  11. Systems/cost summary

    International Nuclear Information System (INIS)

    Grand, P.; Danby, G.; Keane, J.; Spiro, J.; Sutter, D.; Cole, F.; Hoyer, E.; Freytag, K.; Burke, R.

    1977-01-01

    The purpose of the meeting was to discuss and develop cost-estimating methods for heavy-ion fusion accelerator systems. The group did not consider that its purpose was to make technical judgements on proposed systems, but to develop methods for making reasonable cost estimates of these systems. Such estimates will, it is hoped, provide material for systems studies, will help in guiding research and development efforts by identifying ''high-leverage'' subsystems (areas that account for a significant part of total system cost and that might be reduced in cost by further technical development) and to begin to provide data to aid in an eventual decision on the optimum type of accelerator for heavy-ion fusion

  12. Systems/cost: summary

    International Nuclear Information System (INIS)

    Grand, P.; Danby, G.; Keane, J.; Spiro, J.; Sutter, D.; Cole, F.; Hoyer, E.; Freytag, K.; Burke, R.

    1978-01-01

    The purpose of the meeting was to discuss and develop cost-estimating methods for heavy-ion fusion accelerator systems. The group did not consider that its purpose was to make technical judgments on proposed systems, but to develop methods for making reasonable cost estimates of these systems. Such estimates will, it is hoped, provide material for systems studies, will help in guiding research and development efforts by identifying high-leverage subsystems (areas that account for a significant part of total system cost and that might be reduced in cost by further technical development) and to begin to provide data to aid in an eventual decision on the optimum type of accelerator for heavy-ion fusion. The systems considered as examples are: (1) injection system; (2) Wideroe linac; (3) Alvarez linac; (4) induction linac; (5) superconducting accumulator ring; (6) synchrotron; (7) final rf bunching; and (8) final beam transport to target

  13. The System Cost Model: A tool for life cycle cost and risk analysis

    International Nuclear Information System (INIS)

    Hsu, K.; Lundeen, A.; Shropshire, D.; Sherick, M.

    1996-01-01

    In May of 1994, Lockheed Idaho Technologies Company (LITCO) in Idaho Falls, Idaho and subcontractors began development of the System Cost Model (SCM) application. The SCM estimates life cycle costs of the entire US Department of Energy (DOE) complex for designing; constructing; operating; and decommissioning treatment, storage, and disposal (TSD) facilities for mixed low-level, low-level, and transuranic waste. The SCM uses parametric cost functions to estimate life cycle costs for various treatment, storage, and disposal modules which reflect planned and existing waste management facilities at DOE installations. In addition, SCM can model new TSD facilities based on capacity needs over the program life cycle. The user can provide input data (default data is included in the SCM) including the volume and nature of waste to be managed, the time period over which the waste is to be managed, and the configuration of the waste management complex (i.e., where each installation's generated waste will be treated, stored, and disposed). Then the SCM uses parametric cost equations to estimate the costs of pre-operations (designing), construction, operations and maintenance, and decommissioning these waste management facilities. The SCM also provides transportation costs for DOE wastes. Transportation costs are provided for truck and rail and include transport of contact-handled, remote-handled, and alpha (transuranic) wastes. A complement to the SCM is the System Cost Model-Risk (SCM-R) model, which provides relative Environmental, Safety, and Health (ES and H) risk information. A relative ES and H risk basis has been developed and applied by LITCO at the INEL. The risk basis is now being automated in the SCM-R to facilitate rapid risk analysis of system alternatives. The added risk functionality will allow combined cost and risk evaluation of EM alternatives

  14. Combined multi-criteria and cost-benefit analysis

    DEFF Research Database (Denmark)

    Moshøj, Claus Rehfeld

    1996-01-01

    The paper is an introduction to both theory and application of combined Cost-Benefit and Multi-Criteria Analysis. The first section is devoted to basic utility theory and its practical application in Cost-Benefit Analysis. Based on some of the problems encountered, arguments in favour...... of the application of utility-based Multi-Criteria Analyses methods as an extension and refinement of the traditional Cost-Benefit Analysis are provided. The theory presented in this paper is closely related the methods used in the WARP software (Leleur & Jensen, 1989). The presentation is however wider in scope.......The second section introduces the stated preference methodology used in WARP to create weight profiles for project pool sensitivity analysis. This section includes a simple example. The third section discusses how decision makers can get a priori aid to make their pair-wise comparisons based on project pool...

  15. Economic comparison of clean coal generating technologies with natural gas-combined cycle systems

    International Nuclear Information System (INIS)

    Sebesta, J.J.; Hoskins, W.W.

    1990-01-01

    This paper reports that there are four combustion technologies upon which U.S. electric utilities are expected to rely for the majority of their future power generating needs. These technologies are pulverized coal- fired combustion (PC); coal-fired fluidized bed combustion (AFBC); coal gasification, combined cycle systems (CGCC); and natural gas-fired combined cycle systems (NGCC). The engineering and economic parameters which affect the choice of a technology include capital costs, operating and maintenance costs, fuel costs, construction schedule, process risk, environmental and site impacts, fuel efficiency and flexibility, plant availability, capacity factors, timing of startup, and the importance of utility economic and financial factors

  16. (Value Stream Costing As A New Costing System)

    OpenAIRE

    Karcıoğlu, Reşar; Nuray, Meral

    2010-01-01

    In recent years, the number of lean company which use lean manufacturing system is rising. This companies use the standard costing while appropriate for traditional bathch manufacturing. But standard costing system fails to support the goals of lean manufacturing system. A different method of costing based upon the characteristics of the value stream is needed to fulfill the needs of the lean company. This systemis Value Stream Costing. When a lean company moves to value stream management, th...

  17. Prediction of Combine Economic Life Based on Repair and Maintenance Costs Model

    Directory of Open Access Journals (Sweden)

    A Rohani

    2014-09-01

    Full Text Available Farm machinery managers often need to make complex economic decisions on machinery replacement. Repair and maintenance costs can have significant impacts on this economic decision. The farm manager must be able to predict farm machinery repair and maintenance costs. This study aimed to identify a regression model that can adequately represent the repair and maintenance costs in terms of machine age in cumulative hours of use. The regression model has the ability to predict the repair and maintenance costs for longer time periods. Therefore, it can be used for the estimation of the economic life. The study was conducted using field data collected from 11 John-Deer 955 combine harvesters used in several western provinces of Iran. It was found that power model has a better performance for the prediction of combine repair and maintenance costs. The results showed that the optimum replacement age of John-Deer 955 combine was 54300 cumulative hours.

  18. Physical Protection System Upgrades - Optimizing for Performance and Cost

    International Nuclear Information System (INIS)

    Hicks, Mary Jane; Bouchard, Ann M.

    1999-01-01

    CPA--Cost and Performance Analysis--is an architecture that supports analysis of physical protection systems and upgrade options. ASSESS (Analytic System and Software for Evaluating Security Systems), a tool for evaluating performance of physical protection systems, currently forms the cornerstone for evaluating detection probabilities and delay times of the system. Cost and performance data are offered to the decision-maker at the systems level and to technologists at the path-element level. A new optimization engine has been attached to the CPA methodology to automate analyses of many combinations (portfolios) of technologies. That engine controls a new analysis sequencer that automatically modifies ASSESS PPS files (facility descriptions), automatically invokes ASSESS Outsider analysis and then saves results for post-processing. Users can constrain the search to an upper bound on total cost, to a lower bound on level of performance, or to include specific technologies or technology types. This process has been applied to a set of technology development proposals to identify those portfolios that provide the most improvement in physical security for the lowest cost to install, operate and maintain at a baseline facility

  19. The effect of alcohol treatment on social costs of alcohol dependence: results from the COMBINE study.

    Science.gov (United States)

    Zarkin, Gary A; Bray, Jeremy W; Aldridge, Arnie; Mills, Michael; Cisler, Ron A; Couper, David; McKay, James R; O'Malley, Stephanie

    2010-05-01

    The COMBINE (combined pharmacotherapies and behavioral intervention) clinical trial recently evaluated the efficacy of pharmacotherapies, behavioral therapies, and their combinations for the treatment of alcohol dependence. Previously, the cost and cost-effectiveness of COMBINE have been studied. Policy makers, patients, and nonalcohol-dependent individuals may be concerned not only with alcohol treatment costs but also with the effect of alcohol interventions on broader social costs and outcomes. To estimate the sum of treatment costs plus the costs of health care utilization, arrests, and motor vehicle accidents for the 9 treatments in COMBINE 3 years postrandomization. A cost study based on a randomized controlled clinical trial. : The study involved 786 participants 3 years postrandomization. Multivariate results show no significant differences in mean costs between any of the treatment arms as compared with medical management (MM) + placebo for the 3-year postrandomization sample. The median costs of MM + acamprosate, MM + naltrexone, MM + acamprosate + naltrexone, and MM + acamprosate + combined behavioral intervention were significantly lower than the median cost for MM + placebo. The results show that social cost savings are generated relative to MM + placebo by 3 years postrandomization, and the magnitude of these cost savings is greater than the costs of the COMBINE treatment received 3 years prior. Our study suggests that several alcohol treatments may indeed lead to reduced median social costs associated with health care, arrests, and motor vehicle accidents.

  20. Improving patient-level costing in the English and the German 'DRG' system.

    Science.gov (United States)

    Vogl, Matthias

    2013-03-01

    The purpose of this paper is to develop ways to improve patient-level cost apportioning (PLCA) in the English and German inpatient 'DRG' cost accounting systems, to support regulators in improving costing schemes, and to give clinicians and hospital management sophisticated tools to measure and link their management. The paper analyzes and evaluates the PLCA step in the cost accounting schemes of both countries according to the impact on the key aspects of DRG introduction: transparency and efficiency. The goal is to generate a best available PLCA standard with enhanced accuracy and managerial relevance, the main requirements of cost accounting. A best available PLCA standard in 'DRG' cost accounting uses: (1) the cost-matrix from the German system; (2) a third axis in this matrix, representing service-lines or clinical pathways; (3) a scoring system for key cost drivers with the long-term objective of time-driven activity-based costing and (4) a point of delivery separation. Both systems have elements that the other system can learn from. By combining their strengths, regulators are supported in enhancing PLCA systems, improving the accuracy of national reimbursement and the managerial relevance of inpatient cost accounting systems, in order to reduce costs in health care. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Comparison of costs for alternative mixed low-level waste treatment systems

    International Nuclear Information System (INIS)

    Schwinkendorf, W.E.; Harvego, L.; Cooley, C.R.; Biagi, C.

    1996-01-01

    Total life cycle costs (TLCCs), including disposal costs, of thermal, nonthermal and enhanced nonthermal systems were evaluated to guide future research and development programs for the treatment of mixed low-level waste (MLLW) consisting of RCRA hazardous and low-level radioactive wastes. In these studies, nonthermal systems are defined as those systems that process waste at temperatures less than 350 C. Preconceptual designs and costs were developed for thirty systems with a capacity (2,927 lbs/hr) to treat the DOE MLLW stored inventor y(approximately 236 million pounds) in 20 years in a single, centralized facility. A limited comparison of the studies' results is presented in this paper. Sensitivity of treatment costs with respect to treatment capacity, number of treatment facilities, and system availability were also determined. The major cost element is operations and maintenance (O and M), which is 50 to 60% of the TLCC for both thermal and nonthermal systems. Energy costs constitute a small fraction (< 1%) of the TLCCs. Equipment cost is only 3 to 5% of the treatment cost. Evaluation of subsystem costs demonstrate that receiving and preparation is the highest cost subsystem at about 25 to 30% of the TLCC for both thermal and nonthermal systems. These studies found no cost incentives to use nonthermal or hybrid (combined nonthermal treatment with stabilization by vitrification) systems in place of thermal systems. However, there may be other incentives including fewer air emissions and less local objection to a treatment facility. Building multiple treatment facilities to treat the same total mass of waste as a single facility would increase the total treatment cost significantly, and improved system availability decreases unit treatment costs by 17% to 30%

  2. Techno-economic analysis of a coal-fired CHP based combined heating system with gas-fired boilers for peak load compensation

    International Nuclear Information System (INIS)

    Wang Haichao; Jiao Wenling; Lahdelma, Risto; Zou Pinghua

    2011-01-01

    Combined heat and power (CHP) plants dominate the heating market in China. With the ongoing energy structure reformation and increasing environmental concerns, we propose gas-fired boilers to be deployed in underperforming heating substations of heating networks for peak load compensation, in order to improve both energy efficiency and environmental sustainability. However, due to the relatively high price of gas, techno-economic analysis is required for evaluating different combined heating scenarios, characterized by basic heat load ratio (β). Therefore, we employ the dynamic economics and annual cost method to develop a techno-economic model for computing the net heating cost of the system, considering the current state of the art of cogeneration systems in China. The net heating cost is defined as the investment costs and operations costs of the system subtracted by revenues from power generation. We demonstrate the model in a real-life combined heating system of Daqing, China. The results show that the minimum net heating cost can be realized at β=0.75 with a cost reduction of 16.8% compared to coal heating alone. Since fuel cost is the dominating factor, sensitivity analyses on coal and gas prices are discussed subsequently. - Highlights: ► Combined heating systems comply with the energy structure reformation in China. ► We consider the current state of the art of cogeneration systems in China. ► Combined heating systems can be economically more feasible and sustainable. ► The net heating cost of a combined heating system is more sensitive to coal price. ► The optimal basic heat load ratio is more easily influenced by gas price.

  3. Implementation of a Cost-Accounting System for Visibility of Weapon Systems Life-Cycle Costs

    National Research Council Canada - National Science Library

    Ugone, Mary

    2001-01-01

    ... costs through activity-based costing and management. The system must deliver timely, integrated data for management purposes to permit understanding of total weapon costs, provide a basis for estimating costs of future systems, and feed other tools for life-cycle cost management.

  4. Cost-effectiveness analysis of aflibercept in combination with FOLFIRI in the treatment of patients with metastatic colorectal cancer

    Directory of Open Access Journals (Sweden)

    M.ª Echave

    2014-07-01

    Full Text Available Objectives: To estimate the incremental cost per life-year gained (LYG of aflibercept in combination with FOLFIRI as second-line treatment in metastatic colorectal cancer (mCRC patients previously treated with oxaliplatin. Methods: Based on clinical trial VELOUR results, a three-state Markov model (stable disease, progression and death with 2-week cycle duration was designed. Transition to health state «progression» implied the interruption of second-line treatment and administration of a third-line treatment (post-second line chemotherapy. Cost estimation included disease management cost (pharmaceutical, adverse event management, administration costs, etc.. Both cost and outcomes were discounted (3% annually. Sensitivity analyses (SA were performed to test model robustness. Results: Administration of aflibercept + FOLFIRI as second-line treatment provided 1.78 LYG (21 life-months gained. With FOLFIRI 1.43 LYG (17 months were obtained. The cost of the clinical management of aflibercept + FOLFIRI implied an additional investment of 13,564 compared with FOLFIRI for a lifetime horizon, being total costs for aflibercept + FOLFIRI of 38,346, compared to 24,782 with FOLFIRI. In the cost-effectiveness analysis 38,931/LYG was obtained with aflibercept in combination with FOLFIRI versus FOLFIRI. Conclusion: Aflibercept in combination with FOLFIRI increased overall survival versus FOLFIRI, so it is an effective strategy in the treatment of patients with mCRC. Aflibercept in combination with FOLFIRI is an efficient strategy for second-line mCRC treatment from the National Health System perspective.

  5. Performance and cost evaluation of health information systems using micro-costing and discrete-event simulation.

    Science.gov (United States)

    Rejeb, Olfa; Pilet, Claire; Hamana, Sabri; Xie, Xiaolan; Durand, Thierry; Aloui, Saber; Doly, Anne; Biron, Pierre; Perrier, Lionel; Augusto, Vincent

    2018-06-01

    Innovation and health-care funding reforms have contributed to the deployment of Information and Communication Technology (ICT) to improve patient care. Many health-care organizations considered the application of ICT as a crucial key to enhance health-care management. The purpose of this paper is to provide a methodology to assess the organizational impact of high-level Health Information System (HIS) on patient pathway. We propose an integrated performance evaluation of HIS approach through the combination of formal modeling using the Architecture of Integrated Information Systems (ARIS) models, a micro-costing approach for cost evaluation, and a Discrete-Event Simulation (DES) approach. The methodology is applied to the consultation for cancer treatment process. Simulation scenarios are established to conclude about the impact of HIS on patient pathway. We demonstrated that although high level HIS lengthen the consultation, occupation rate of oncologists are lower and quality of service is higher (through the number of available information accessed during the consultation to formulate the diagnostic). The provided method allows also to determine the most cost-effective ICT elements to improve the care process quality while minimizing costs. The methodology is flexible enough to be applied to other health-care systems.

  6. Cost-minimized combinations of wind power, solar power and electrochemical storage, powering the grid up to 99.9% of the time

    DEFF Research Database (Denmark)

    Budischak, Cory; Sewell, DeAnna; Thomson, Heather

    2013-01-01

    intermittent power, we seek combinations of diverse renewables at diverse sites, with storage, that are not intermittent and satisfy need a given fraction of hours. And 2) we seek minimal cost, calculating true cost of electricity without subsidies and with inclusion of external costs. Our model evaluated over...... renewable generation and the excess capacity together meet electric load with less storage, lowering total system cost. At 2030 technology costs and with excess electricity displacing natural gas, we find that the electric system can be powered 90%–99.9% of hours entirely on renewable electricity, at costs...

  7. Pricing strategies for combination pediatric vaccines based on the lowest overall cost formulary.

    Science.gov (United States)

    Behzad, Banafsheh; Jacobson, Sheldon H; Sewell, Edward C

    2012-10-01

    This paper analyzes pricing strategies for US pediatric combination vaccines by comparing the lowest overall cost formularies (i.e., formularies that have the lowest overall cost). Three pharmaceutical companies compete pairwise over the sale of monovalent and combination vaccines. Particular emphasis is placed on examining the price of Sanofi Pasteur's DTaP-IPV/HIb under different conditions. The main contribution of the paper is to provide the lowest overall cost formularies for different prices of DTaP-IPV/HIb and other Sanofi Pasteur vaccines. The resulting analysis shows that DTaP-IPV/HIb could have been more competitively priced compared with the combination vaccine DTaP-HepB-IPV, for federal contract prices in 2009, 2010 and 2011. This study also proposes the lowest overall cost formularies when shortages of monovalent vaccines occur.

  8. COMBINED SYSTEMS OF ENERGY GENERATION – A CHARACTERISATION AND CLASSIFICATION

    Directory of Open Access Journals (Sweden)

    Jan Gilewski

    2014-09-01

    Full Text Available The study presents issues concerning technical solutions of combined systems of energy generation which can be used primarily in low-level power plants, installed in various types of public utility sites. A detailed description is given of selected ways of powering combined energy generation systems, presenting conceptual outlines of their operation and information on their advantages, disadvantages and applications. The following systems are introduced: gas-steam, back-pressure steam turbine, extraction-condensing steam turbine, gas turbine, gas microturbine, Stirling engine, fuel cells and internal combustion piston engine. Moreover, the study addresses economic aspects of energy generation in combined systems, discussing different methodologies of cost calculation, including the one used by the European Union. The article also gives a detailed review of piston engine combined-system aggregates available in the Polish market. Type series of associated systems designed for low-power appliances are shown, produced by Polish and foreign companies such as Viessmann, Centrum Elektroniki Stosowanej CES, H. Cegielski – Poznań, KWE Technika Energetyczna, TEDOM Poland or the EPS System.

  9. Cost of increasing access to artemisinin combination therapy: the Cambodian experience

    Directory of Open Access Journals (Sweden)

    Socheat Duong

    2008-05-01

    Full Text Available Abstract Background Malaria-endemic countries are switching antimalarial drug policy from cheap ineffective monotherapies to artemisinin combination therapies (ACTs for the treatment of Plasmodium falciparum malaria and the global community are considering setting up a global subsidy to fund their purchase. However, in order to ensure that ACTs are correctly used and are accessible to the poor and remote communities who need them, specific interventions will be necessary and the additional costs need to be considered. Methods This paper presents an incremental cost analysis of some of these interventions in Cambodia, the first country to change national antimalarial drug policy to an ACT of artesunate and mefloquine. These costs include the cost of rapid diagnostic tests (RDTs, the cost of blister-packaging the drugs locally and the costs of increasing access to diagnosis and treatment to remote communities through malaria outreach teams (MOTs and Village Malaria Workers (VMW. Results At optimum productive capacity, the cost of blister-packaging cost under $0.20 per package but in reality was significantly more than this because of the low rate of production. The annual fixed cost (exclusive of RDTs and drugs per capita of the MOT and VMW schemes was $0.44 and $0.69 respectively. However because the VMW scheme achieved a higher rate of coverage than the MOT scheme, the cost per patient treated was substantially lower at $5.14 compared to $12.74 per falciparum malaria patient treated. The annual cost inclusive of the RDTs and drugs was $19.31 for the MOT scheme and $11.28 for the VMW scheme given similar RDT positivity rates of around 22% and good provider compliance to test results. Conclusion In addition to the cost of ACTs themselves, substantial additional investments are required in order to ensure that they reach the targeted population via appropriate delivery systems and to ensure that they are used appropriately. In addition, differences

  10. Cost-effectiveness of Paclitaxel + Ramucirumab Combination Therapy for Advanced Gastric Cancer Progressing After First-line Chemotherapy in Japan.

    Science.gov (United States)

    Saito, Shota; Muneoka, Yusuke; Ishikawa, Takashi; Akazawa, Kouhei

    2017-12-01

    The combination of paclitaxel + ramucirumab is a standard second-line treatment in patients with advanced gastric cancer. This therapy has been associated with increased median overall survival and progression-free survival compared with those with paclitaxel monotherapy. We evaluated the cost-effectiveness of paclitaxel + ramucirumab combination therapy in patients with advanced gastric cancer, from the perspective of health care payers in Japan. We constructed a Markov model to compare, over a time horizon of 3 years, the costs and effectiveness of the combination of paclitaxel + ramucirumab and paclitaxel alone as second-line therapies for advanced gastric cancer in Japan. Health outcomes were measured in life-years (LYs) and quality-adjusted (QA) LYs gained. Costs were calculated using year-2016 Japanese yen (¥1 = US $17.79) according to the social insurance reimbursement schedule and drug tariff of the fee-for-service system in Japan. Model robustness was addressed through 1-way and probabilistic sensitivity analyses. The costs and QALYs were discounted at a rate of 2% per year. The willingness-to-pay threshold was set at the World Health Organization's criterion of ¥12 million, because no consensus exists regarding the threshold for acceptable cost per QALY ratios in Japan's health policy. Paclitaxel + ramucirumab combination therapy was estimated to provide an additional 0.09 QALYs (0.10 LYs) at a cost of ¥3,870,077, resulting in an incremental cost-effectiveness ratio of ¥43,010,248/QALY. The incremental cost-effectiveness ratio for the combination therapy was >¥12 million/QALY in all of the 1-way and probabilistic sensitivity analyses. Adding ramucirumab to a regimen of paclitaxel in the second-line treatment of advanced gastric cancer is expected to provide a minimal incremental benefit at a high incremental cost per QALY. Based on our findings, adjustments in the price of ramucirumab, as well as improves in other clinical parameters such as survival

  11. A Total Cost of Ownership Model for Low Temperature PEM Fuel Cells in Combined Heat and Power and Backup Power Applications

    Energy Technology Data Exchange (ETDEWEB)

    University of California, Berkeley; Wei, Max; Lipman, Timothy; Mayyas, Ahmad; Chien, Joshua; Chan, Shuk Han; Gosselin, David; Breunig, Hanna; Stadler, Michael; McKone, Thomas; Beattie, Paul; Chong, Patricia; Colella, Whitney; James, Brian

    2014-06-23

    A total cost of ownership model is described for low temperature proton exchange membrane stationary fuel cell systems for combined heat and power (CHP) applications from 1-250kW and backup power applications from 1-50kW. System designs and functional specifications for these two applications were developed across the range of system power levels. Bottom-up cost estimates were made for balance of plant costs, and detailed direct cost estimates for key fuel cell stack components were derived using design-for-manufacturing-and-assembly techniques. The development of high throughput, automated processes achieving high yield are projected to reduce the cost for fuel cell stacks to the $300/kW level at an annual production volume of 100 MW. Several promising combinations of building types and geographical location in the U.S. were identified for installation of fuel cell CHP systems based on the LBNL modelling tool DER CAM. Life-cycle modelling and externality assessment were done for hotels and hospitals. Reduced electricity demand charges, heating credits and carbon credits can reduce the effective cost of electricity ($/kWhe) by 26-44percent in locations such as Minneapolis, where high carbon intensity electricity from the grid is displaces by a fuel cell system operating on reformate fuel. This project extends the scope of existing cost studies to include externalities and ancillary financial benefits and thus provides a more comprehensive picture of fuel cell system benefits, consistent with a policy and incentive environment that increasingly values these ancillary benefits. The project provides a critical, new modelling capacity and should aid a broad range of policy makers in assessing the integrated costs and benefits of fuel cell systems versus other distributed generation technologies.

  12. Evaluation of advanced coal gasification combined-cycle systems under uncertainty

    International Nuclear Information System (INIS)

    Frey, H.C.; Rubin, E.S.

    1992-01-01

    Advanced integrated gasification combined cycle (IGCC) systems have not been commercially demonstrated, and uncertainties remain regarding their commercial-scale performance and cost. Therefore, a probabilistic evaluation method has been developed and applied to explicitly consider these uncertainties. The insights afforded by this method are illustrated for an IGCC design featuring a fixed-bed gasifier and a hot gas cleanup system. Detailed case studies are conducted to characterize uncertainties in key measures of process performance and cost, evaluate design trade-offs under uncertainty, identify research priorities, evaluate the potential benefits of additional research, compare results for different uncertainty assumptions, and compare the advanced IGCC system to a conventional system under uncertainty. The implications of probabilistic results for research planning and technology selection are discussed in this paper

  13. A systems engineering cost analysis capability for use in assessing nuclear waste management system cost performance

    International Nuclear Information System (INIS)

    Shay, M.R.

    1990-04-01

    The System Engineering Cost Analysis (SECA) capability has been developed by the System Integration Branch of the US Department of Energy's Office of Civilian Radioactive Waste Management for use in assessing the cost performance of alternative waste management system configurations. The SECA capability is designed to provide rapid cost estimates of the waste management system for a given operational scenario and to permit aggregate or detailed cost comparisons for alternative waste system configurations. This capability may be used as an integral part of the System Integration Modeling System (SIMS) or, with appropriate input defining a scenario, as a separate cost analysis model

  14. Improving hospital cost accounting with activity-based costing.

    Science.gov (United States)

    Chan, Y C

    1993-01-01

    In this article, activity-based costing, an approach that has proved to be an improvement over the conventional costing system in product costing, is introduced. By combining activity-based costing with standard costing, health care administrators can better plan and control the costs of health services provided while ensuring that the organization's bottom line is healthy.

  15. Combined heat and power system with advanced gasification technology for biomass wastes

    Energy Technology Data Exchange (ETDEWEB)

    Mochida, S.; Abe, T.; Yasuda, T. [Nippon Furnace Kogyo Kaisha Ltd, Yokohama (Japan); Gupta, A.K. [Maryland Univ., College Park, MD (United States). Dept. of Mechnical Engineering

    2013-07-01

    The results obtained from an advanced gasification system utilizing high temperature steam are presented here. The results showed successful demonstration of clean syngas production having high calorific value fuel ({proportional_to}10 MJ/m{sup 3}N) using woody biomass wastes in a downdraft type gasifier. The gasification capacity of the plant on dry basis was 60 kg/h. The syngas produced can be utilized in an absorption type chiller for air conditioning. This advanced gasification technology allows one to transform wastes to clean energy at local production sites without any environmental impact and expensive waste transportation costs. The experience gained from the demonstration plant allows one to implement to other industrial applications for use as a decentralized unit and obtain clean syngas for local use. The demonstration conducted here shows that the system is favorable for onsite use of compatible combined heat and power (CHP) system including light oil supported diesel engine power generator. The biomass waste fuel from a lumber mill factory was used in this study. The factory handles a wide forests area of about 50 ha and produces about 2,500 m{sup 3}/year of wood chips from thin out trees and waste lumbers. This translates to a maximum 110 kg/h of wood chips that can be fed to a gasifier. The syngas produced was used for the combined heat and power system. Local use of biomass for fuel reforming reduces the cost of collection and transportation costs so that a sustainable business is demonstrated with profit from the generated electricity and thermal energy. The cost structure incorporates both the depreciation cost and operation cost of the system. Thermal energy from hot water can be used for drying lumbers and wood chips in a cascade manner. The drying process can be adopted for enhancing its productivity with increased variability on the quality of lumber. The results show that the combined heat and power system (CHP) offers good profitable

  16. AES, Automated Construction Cost Estimation System

    International Nuclear Information System (INIS)

    Holder, D.A.

    1995-01-01

    A - Description of program or function: AES (Automated Estimating System) enters and updates the detailed cost, schedule, contingency, and escalation information contained in a typical construction or other project cost estimates. It combines this information to calculate both un-escalated and escalated and cash flow values for the project. These costs can be reported at varying levels of detail. AES differs from previous versions in at least the following ways: The schedule is entered at the WBS-Participant, Activity level - multiple activities can be assigned to each WBS-Participant combination; the spending curve is defined at the schedule activity level and a weighing factor is defined which determines percentage of cost for the WBS-Participant applied to the schedule activity; Schedule by days instead of Fiscal Year/Quarter; Sales Tax is applied at the Line Item Level- a sales tax codes is selected to indicate Material, Large Single Item, or Professional Services; a 'data filter' has been added to allow user to define data the report is to be generated for. B - Method of solution: Average Escalation Rate: The average escalation for a Bill of is calculated in three steps. 1. A table of quarterly escalation factors is calculated based on the base fiscal year and quarter of the project entered in the estimate record and the annual escalation rates entered in the Standard Value File. 2. The percentage distribution of costs by quarter for the Bill of Material is calculated based on the schedule entered and the curve type. 3. The percent in each fiscal year and quarter in the distribution is multiplied by the escalation factor for the fiscal year and quarter. The sum of these results is the average escalation rate for that Bill of Material. Schedule by curve: The allocation of costs to specific time periods is dependent on three inputs, starting schedule date, ending schedule date, and the percentage of costs allocated to each quarter. Contingency Analysis: The

  17. Private-sector vaccine purchase costs and insurer payments: a disincentive for using combination vaccines?

    Science.gov (United States)

    Clark, Sarah J; Cowan, Anne E; Freed, Gary L

    2011-04-01

    Combination vaccines have been endorsed as a means to decrease the number of injections needed to complete the childhood immunization schedule, yet anecdotal reports suggest that private providers lose money on combination vaccines. The objective of this study was to determine whether practices purchasing combination vaccines had significantly different vaccine costs and reimbursement compared to practices that were not purchasing combination vaccines. Using cross-sectional purchase and insurer payment data collected from a targeted sample of private practices in five US states, we calculated the average total vaccine cost and reimbursement across the childhood immunization schedule. The average vaccine purchase cost across the childhood schedule was significantly higher for practices using a combined vaccine with diphtheria, tetanus, acellular pertussis vaccine, inactivated polio vaccine, and Hepatitis B vaccine (DTaP-IPV-HepB) than for practices using either separate vaccine products or a combined vaccine with Haemophilus influenzae, type b vaccine and Hepatitis B vaccine (Hib-HepB). The average insurer payment for vaccine administration across the childhood schedule was significantly lower for practices using DTaP-IPV-HepB combination vaccine than for practices using separate vaccine products. This study appears to validate anecdotal reports that vaccine purchase costs and insurer payment for combination vaccines can have a negative financial impact for practices that purchase childhood vaccines.

  18. A Layered Decision Model for Cost-Effective System Security

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Huaqiang; Alves-Foss, James; Soule, Terry; Pforsich, Hugh; Zhang, Du; Frincke, Deborah A.

    2008-10-01

    System security involves decisions in at least three areas: identification of well-defined security policies, selection of cost-effective defence strategies, and implementation of real-time defence tactics. Although choices made in each of these areas affect the others, existing decision models typically handle these three decision areas in isolation. There is no comprehensive tool that can integrate them to provide a single efficient model for safeguarding a network. In addition, there is no clear way to determine which particular combinations of defence decisions result in cost-effective solutions. To address these problems, this paper introduces a Layered Decision Model (LDM) for use in deciding how to address defence decisions based on their cost-effectiveness. To validate the LDM and illustrate how it is used, we used simulation to test model rationality and applied the LDM to the design of system security for an e-commercial business case.

  19. Sizing Combined Heat and Power Units and Domestic Building Energy Cost Optimisation

    OpenAIRE

    Dongmin Yu; Yuanzhu Meng; Gangui Yan; Gang Mu; Dezhi Li; Simon Le Blond

    2017-01-01

    Many combined heat and power (CHP) units have been installed in domestic buildings to increase energy efficiency and reduce energy costs. However, inappropriate sizing of a CHP may actually increase energy costs and reduce energy efficiency. Moreover, the high manufacturing cost of batteries makes batteries less affordable. Therefore, this paper will attempt to size the capacity of CHP and optimise daily energy costs for a domestic building with only CHP installed. In this paper, electricity ...

  20. The relationship between cost system complexity, purposes of use, and cost system effectiveness

    NARCIS (Netherlands)

    Schoute, M.

    2009-01-01

    This paper uses survey data from 133 Dutch, medium-sized manufacturing firms to examine the associations between cost system complexity (in terms of the applied overhead absorption procedures), purposes of use, and cost system effectiveness. First, factor analysis identifies two underlying

  1. Quality cost system in electronics

    International Nuclear Information System (INIS)

    Denzer, H.O.

    1978-01-01

    A description is presented of a formal cost of quality system used in an electronic manufacturing facility. The system elements and reports are illustrated. Examples of the use of a quality cost system to measure quality performance and to improve product quality are included. A comparison to industry averages for quality costs is made. The paper attempts to show that the collection and use of quality costs are an aid to management and can be accompanied by improved product quality

  2. Combined cycle solar central receiver hybrid power system study. Final technical report. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-11-01

    This study develops the conceptual design for a commercial-scale (nominal 100 MWe) central receiver solar/fossil fuel hybrid power system with combined cycle energy conversion. A near-term, metallic heat pipe receiver and an advanced ceramic tube receiver hybrid system are defined through parametric and market potential analyses. Comparative evaluations of the cost of power generation, the fuel displacement potential, and the technological readiness of these two systems indicate that the near-term hybrid system has better potential for commercialization by 1990. Based on the assessment of the conceptual design, major cost and performance improvements are projected for the near-term system. Constraints preventing wide-spread use were not identified. Energy storage is not required for this system and analyses show no economic advantages with energy storage provisions. It is concluded that the solar hybrid system is a cost effective alternative to conventional gas turbines and combined cycle generating plants, and has potential for intermediate-load market penetration at 15% annual fuel escalation rate. Due to their flexibility, simple solar/nonsolar interfacing, and short startup cycles, these hybrid plants have significant operating advantages. Utility company comments suggest that hybrid power systems will precede stand-alone solar plants.

  3. Performance and costs of a roof-sized PV/thermal array combined with a ground coupled heat pump

    International Nuclear Information System (INIS)

    Bakker, M.; Zondag, H.A.; Elswijk, M.J.; Strootman, K.J.; Jong, M.J.M.

    2005-03-01

    A photovoltaic/thermal (PVT) panel is a combination of photovoltaic cells with a solar thermal collector, generating solar electricity and solar heat simultaneously. Hence, PVT panels are an alternative for a combination of separate PV panels and solar thermal collectors. A promising system concept, consisting of 25 m 2 of PVT panels and a ground coupled heat pump, has been simulated in TRNSYS. It has been found that this system is able to cover 100% of the total heat demand for a typical newly-built Dutch one-family dwelling, while covering nearly all of its own electricity use and keeping the long-term average ground temperature constant. The cost of such a system has been compared to the cost of a reference system, where the PVT panels have been replaced with separate PV panels (26 m 2 ) and solar thermal collectors (7 m 2 ), but which is otherwise identical. The electrical and thermal yield of this reference system is equal to that of the PVT system. It has been found that both systems require a nearly identical initial investment. Finally, a view on future PVT markets is given. In general, the residential market is by far the most promising market. The system discussed in this paper is expected to be most successful in newly-built low-energy housing concepts

  4. Performance and costs of a roof-sized PV/thermal array combined with a ground coupled heat pump

    International Nuclear Information System (INIS)

    Bakker, M.; Zondag, H.A.; Elswijk, M.J.; Strootman, K.J.; Jong, M.J.M.

    2005-01-01

    A photovoltaic/thermal (PVT) panel is a combination of photovoltaic cells with a solar thermal collector, generating solar electricity and solar heat simultaneously. Hence, PVT panels are an alternative for a combination of separate PV panels and solar thermal collectors. A promising system concept, consisting of 25 m 2 of PVT panels and a ground coupled heat pump, has been simulated in TRNSYS. It has been found that this system is able to cover 100% of the total heat demand for a typical newly-built Dutch one-family dwelling, while covering nearly all of its own electricity use and keeping the long-term average ground temperature constant. The cost of such a system has been compared to the cost of a reference system, where the PVT panels have been replaced with separate PV panels (26 m 2 ) and solar thermal collectors (7 m 2 ), but which is otherwise identical. The electrical and thermal yield of this reference system is equal to that of the PVT system. It has been found that both systems require a nearly identical initial investment. Finally, a view on future PVT markets is given. In general, the residential market is by far the most promising market. The system discussed in this paper is expected to be most successful in newly-built low-energy housing concepts. (Author)

  5. Techno-Economic Feasibility of Highly Efficient Cost-Effective Thermoelectric-SOFC Hybrid Power Generation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Jifeng Zhang; Jean Yamanis

    2007-09-30

    Solid oxide fuel cell (SOFC) systems have the potential to generate exhaust gas streams of high temperature, ranging from 400 to 800 C. These high temperature gas streams can be used for additional power generation with bottoming cycle technologies to achieve higher system power efficiency. One of the potential candidate bottoming cycles is power generation by means of thermoelectric (TE) devices, which have the inherent advantages of low noise, low maintenance and long life. This study was to analyze the feasibility of combining coal gas based SOFC and TE through system performance and cost techno-economic modeling in the context of multi-MW power plants, with 200 kW SOFC-TE module as building blocks. System and component concepts were generated for combining SOFC and TE covering electro-thermo-chemical system integration, power conditioning system (PCS) and component designs. SOFC cost and performance models previously developed at United Technologies Research Center were modified and used in overall system analysis. The TE model was validated and provided by BSST. The optimum system in terms of energy conversion efficiency was found to be a pressurized SOFC-TE, with system efficiency of 65.3% and cost of $390/kW of manufacturing cost. The pressurization ratio was approximately 4 and the assumed ZT of the TE was 2.5. System and component specifications were generated based on the modeling study. The major technology and cost barriers for maturing the system include pressurized SOFC stack using coal gas, the high temperature recycle blowers, and system control design. Finally, a 4-step development roadmap is proposed for future technology development, the first step being a 1 kW proof-of-concept demonstration unit.

  6. Evaluation of the performance of combined cooling, heating, and power systems with dual power generation units

    International Nuclear Information System (INIS)

    Knizley, Alta A.; Mago, Pedro J.; Smith, Amanda D.

    2014-01-01

    The benefits of using a combined cooling, heating, and power system with dual power generation units (D-CCHP) is examined in nine different U.S. locations. One power generation unit (PGU) is operated at base load while the other is operated following the electric load. The waste heat from both PGUs is used for heating and for cooling via an absorption chiller. The D-CCHP configuration is studied for a restaurant benchmark building, and its performance is quantified in terms of operational cost, primary energy consumption (PEC), and carbon dioxide emissions (CDE). Cost spark spread, PEC spark spread, and CDE spark spread are examined as performance indicators for the D-CCHP system. D-CCHP system performance correlates well with spark spreads, with higher spark spreads signifying greater savings through implementation of a D-CCHP system. A new parameter, thermal difference, is introduced to investigate the relative performance of a D-CCHP system compared to a dual PGU combined heat and power system (D-CHP). Thermal difference, together with spark spread, can explain the variation in savings of a D-CCHP system over a D-CHP system for each location. The effect of carbon credits on operational cost savings with respect to the reference case is shown for selected locations. - Highlights: • We investigate benefits from using combined cooling, heating, and power systems. • A dual power generation unit configuration is considered for CCHP and CHP. • Spark spreads for cost, energy, and emissions correlate with potential savings. • Thermal difference parameter helps to explain variations in potential savings. • Carbon credits may increase cost savings where emissions savings are possible

  7. Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region

    Directory of Open Access Journals (Sweden)

    Jean-Ann James

    2016-12-01

    Full Text Available The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP systems have the potential to improve the energy generation efficiency of a city or urban region by providing energy for heating, cooling, and electricity simultaneously. The purpose of this study is to estimate the water consumption for energy generation use, carbon dioxide (CO2 and NOx emissions, and economic impact of implementing CCHP systems for five generic building types within the Atlanta metropolitan region, under various operational scenarios following the building thermal (heating and cooling demands. Operating the CCHP system to follow the hourly thermal demand reduces CO2 emissions for most building types both with and without net metering. The system can be economically beneficial for all building types depending on the price of natural gas, the implementation of net metering, and the cost structure assumed for the CCHP system. The greatest reduction in water consumption for energy production and NOx emissions occurs when there is net metering and when the system is operated to meet the maximum yearly thermal demand, although this scenario also results in an increase in greenhouse gas emissions and, in some cases, cost. CCHP systems are more economical for medium office, large office, and multifamily residential buildings.

  8. Combined analyses of costs, market value and eco-costs in circular business models : eco-efficient value creation in remanufacturing

    NARCIS (Netherlands)

    Vogtländer, J.G.; Scheepens, A.E.; Bocken, N.M.P.; Peck, D.P.

    2017-01-01

    Eco-efficient Value Creation is a method to analyse innovative product and service design together with circular business strategies. The method is based on combined analyses of the costs, market value (perceived customer value) and eco-costs. This provides a prevention-based single indicator for

  9. Comparison of cost determination of both resource consumption accounting and time-driven activity-based costing systems in a healthcare setting.

    Science.gov (United States)

    Özyapıcı, Hasan; Tanış, Veyis Naci

    2017-05-01

    Objective The aim of the present study was to explore the differences between resource consumption accounting (RCA) and time-driven activity-based costing (TDABC) systems in determining the costs of services of a healthcare setting. Methods A case study was conducted to calculate the unit costs of open and laparoscopic gall bladder surgeries using TDABC and RCA. Results The RCA system assigns a higher cost both to open and laparoscopic gall bladder surgeries than TDABC. The total cost of unused capacity under the TDABC system is also double that in RCA. Conclusion Unlike TDABC, RCA calculates lower costs for unused capacities but higher costs for products or services in a healthcare setting in which fixed costs make up a high proportion of total costs. What is known about the topic? TDABC is a revision of the activity-based costing (ABC) system. RCA is also a new costing system that includes both the theoretical advantages of ABC and the practical advantages of German costing. However, little is known about the differences arising from application of TDABC and RCA. What does this paper add? There is no study comparing both TDABC and RCA in a single case study based on a real-world healthcare setting. Thus, the present study fills this gap in the literature and it is unique in the sense that it is the first case study comparing TDABC and RCA for open and laparoscopic gall bladder surgeries in a healthcare setting. What are the implications for practitioners? This study provides several interesting results for managers and cost accounting researchers. Thus, it will contribute to the spread of RCA studies in healthcare settings. It will also help the implementers of TDABC to revise data concerning the cost of unused capacity. In addition, by separating costs into fixed and variable, the paper will help managers to create a blended (combined) system that can improve both short- and long-term decisions.

  10. Cost-effectiveness optimization of a solar hot water heater with integrated storage system

    International Nuclear Information System (INIS)

    Kamaruzzaman Sopian; Syahri, M.; Shahrir, A.; Mohd Yusof Othman; Baharuddin Yatim

    2006-01-01

    Solar processes are generally characterized by high first cost and low operating costs. Therefore, the basic economic problem is one of comparing an initial known investment with estimated future operating cost. This paper present the cost-benefit ratio of solar collector with integrated storage system. Evaluation of the annual cost (AC) and the annual energy gain (AEG) of the collector are performed and the ratio of AC/AEG or the cost benefit ratio is presented for difference combination of mass flow rate, solar collector length and channel depth. Using these cost-effectiveness curves, the user can select optimum design features, which correspond to minimum AC/AEG

  11. Production costs: U.S. gas turbine ampersand combined-cycle power plants

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This fourth edition of UDI's gas turbine O ampersand M cost report gives 1991 operation and maintenance expenses for over 450 US gas turbine power plants. Modeled on UDI's popular series of O ampersand M cost reports for US steam-electric plants, this report shows operator and plant name, plant year-in-service, installed capacity, 1991 net generation, total fuel expenses, total non-fuel O ampersand M expenses, total production costs, and current plant capitalization. Coverage includes over 90 percent of the utility-owned gas/combustion turbine and combined-cycle plants installed in the country

  12. Comparing the Cost-Effectiveness of Campaigns Delivered via Various Combinations of Television and Online Media.

    Science.gov (United States)

    Allom, Vanessa; Jongenelis, Michelle; Slevin, Terry; Keightley, Stacey; Phillips, Fiona; Beasley, Sarah; Pettigrew, Simone

    2018-01-01

    Reflecting the increasing prevalence of online media, many mass media health campaigns are now delivered using both television (TV) and online media formats. The aim of this study was to evaluate a smoking cessation mass media campaign according to the cost-effectiveness of the various combinations of TV and online media formats to inform future media buying decisions. A quasi-experimental interrupted time series approach was employed. The campaign was delivered in seven 1-week bursts using TV, online video (OV), or online display (OD) (e.g., banner ads) formats in isolation and in various combinations over a 13-week period. Campaign bursts were separated by "off-weeks" in which no campaign materials were delivered. Assessed outcomes were the number of campaign response "events" recorded (campaign web page views, calls to a smoking cessation telephone service, and registrations for smoking cessation services). The cost-effectiveness of each individual and combined media format condition in terms of these outcome variables was calculated using attributed production and broadcasting costs. Overall, OD alone was found to be the most cost-effective means of achieving the nominated campaign outcomes, followed by a combination of OV and OD and a combination of TV and OV. The use of TV in isolation was the least cost-effective. The results of this evaluation indicate that online media constitute a promising means of enhancing the cost-effectiveness of smoking cessation campaigns. Future research assessing a broader range of outcomes, especially smoking cessation, is needed to provide a more comprehensive account of the cost-effectiveness of various campaign media.

  13. Combined methodology of optimization and life cycle inventory for a biomass gasification based BCHP system

    International Nuclear Information System (INIS)

    Wang, Jiang-Jiang; Yang, Kun; Xu, Zi-Long; Fu, Chao; Li, Li; Zhou, Zun-Kai

    2014-01-01

    Biomass gasification based building cooling, heating, and power (BCHP) system is an effective distributed energy system to improve the utilization of biomass resources. This paper proposes a combined methodology of optimization method and life cycle inventory (LCI) for the biomass gasification based BCHP system. The life cycle models including biomass planting, biomass collection-storage-transportation, BCHP plant construction and operation, and BCHP plant demolition and recycle, are constructed to obtain economic cost, energy consumption and CO 2 emission in the whole service-life. Then, the optimization model for the biomass BCHP system including variables, objective function and solution method are presented. Finally, a biomass BCHP case in Harbin, China, is optimized under different optimization objectives, the life-cycle performances including cost, energy and CO 2 emission are obtained and the grey incidence approach is employed to evaluate their comprehensive performances of the biomass BCHP schemes. The results indicate that the life-cycle cost, energy efficiency and CO 2 emission of the biomass BCHP system are about 41.9 $ MWh −1 , 41% and 59.60 kg MWh −1 respectively. The optimized biomass BCHP configuration to minimize the life-cycle cost is the best scheme to achieve comprehensive benefit including cost, energy consumption, renewable energy ratio, steel consumption, and CO 2 emission. - Highlights: • Propose the combined method of optimization and LCI for biomass BCHP system. • Optimize the biomass BCHP system to minimize the life-cycle cost, energy and emission. • Obtain the optimized life-cycle cost, energy efficiency and CO 2 emission. • Select the best biomass BCHP scheme using grey incidence approach

  14. Optimization of Serial Combined System of Ground-Coupled Heat Pump and Solar Collector

    Institute of Scientific and Technical Information of China (English)

    ZHAO Jun; CHEN Yan; LU Suzhen; CUI Junkui

    2009-01-01

    A mathematical optimization model was set up for a ground-solar combined system based on in-situ experimental results,in which the solar collector was combined serially with a ground-coupled heat pump(GCHP).The universal optimal equations were solved by the constrained variable metric method considering both the performance and economics.Then the model was applied to a specific case concerning an actual solar assisted GCHP system for space heating.The results indicated a system coefficient of performance(COP)of 3.9 for the optimal method under the seriaI heating mode,and 3.2 for the conventional one.In addition,the optimum solution also showed advantages in energy and cost saving.1eading to a 16.7%improvement in the heat pump performance at 17.2%less energy consumption and 11.8%lower annual cost,respectively.

  15. Optimization of fog inlet air cooling system for combined cycle power plants using genetic algorithm

    International Nuclear Information System (INIS)

    Ehyaei, Mehdi A.; Tahani, Mojtaba; Ahmadi, Pouria; Esfandiari, Mohammad

    2015-01-01

    In this research paper, a comprehensive thermodynamic modeling of a combined cycle power plant is first conducted and the effects of gas turbine inlet fogging system on the first and second law efficiencies and net power outputs of combined cycle power plants are investigated. The combined cycle power plant (CCPP) considered for this study consist of a double pressure heat recovery steam generator (HRSG) to utilize the energy of exhaust leaving the gas turbine and produce superheated steam to generate electricity in the Rankine cycle. In order to enhance understanding of this research and come up with optimum performance assessment of the plant, a complete optimization is using a genetic algorithm conducted. In order to achieve this goal, a new objective function is defined for the system optimization including social cost of air pollution for the power generation systems. The objective function is based on the first law efficiency, energy cost and the external social cost of air pollution for an operational system. It is concluded that using inlet air cooling system for the CCPP system and its optimization results in an increase in the average output power, first and second law efficiencies by 17.24%, 3.6% and 3.5%, respectively, for three warm months of year. - Highlights: • To model the combined cycle power plant equipped with fog inlet air cooling method. • To conduct both exergy and economic analyses for better understanding. • To conduct a complete optimization using a genetic algorithm to determine the optimal design parameters of the system

  16. Is the system really the solution? Operating costs in hospital systems.

    Science.gov (United States)

    Burns, Lawton Robert; McCullough, Jeffrey S; Wholey, Douglas R; Kruse, Gregory; Kralovec, Peter; Muller, Ralph

    2015-06-01

    Hospital system formation has recently accelerated. Executives emphasize scale economies that lower operating costs, a claim unsupported in academic research. Do systems achieve lower costs than freestanding facilities, and, if so, which system types? We test hypotheses about the relationship of cost with membership in systems, larger systems, and centralized and local hub-and-spoke systems. We also test whether these relationships have changed over time. Examining 4,000 U.S. hospitals during 1998 to 2010, we find no evidence that system members exhibit lower costs. However, members of smaller systems are lower cost than larger systems, and hospitals in centralized systems are lower cost than everyone else. There is no evidence that the system's spatial configuration is associated with cost, although national system hospitals exhibit higher costs. Finally, these results hold over time. We conclude that while systems in general may not be the solution to lower costs, some types of systems are. © The Author(s) 2015.

  17. Cost system design and cost management in the Spanish public sector

    OpenAIRE

    Boned, Josep Lluís; Bagur, Llorenç; Tayles, Mike

    2006-01-01

    Cost systems have been shown to have developed considerably in recent years and activity-based costing (ABC) has been shown to be a contribution to cost management, particularly in service businesses. The public sector is composed to a very great extent of service functions, yet considerably less has been reported of the use of ABC to support cost management in this sector. In Spain, cost systems are essential for city councils as they are obliged to calculate the cost of the services subject...

  18. Comparing the Cost-Effectiveness of Campaigns Delivered via Various Combinations of Television and Online Media

    Directory of Open Access Journals (Sweden)

    Vanessa Allom

    2018-03-01

    Full Text Available BackgroundReflecting the increasing prevalence of online media, many mass media health campaigns are now delivered using both television (TV and online media formats. The aim of this study was to evaluate a smoking cessation mass media campaign according to the cost-effectiveness of the various combinations of TV and online media formats to inform future media buying decisions.MethodsA quasi-experimental interrupted time series approach was employed. The campaign was delivered in seven 1-week bursts using TV, online video (OV, or online display (OD (e.g., banner ads formats in isolation and in various combinations over a 13-week period. Campaign bursts were separated by “off-weeks” in which no campaign materials were delivered. Assessed outcomes were the number of campaign response “events” recorded (campaign web page views, calls to a smoking cessation telephone service, and registrations for smoking cessation services. The cost-effectiveness of each individual and combined media format condition in terms of these outcome variables was calculated using attributed production and broadcasting costs.ResultsOverall, OD alone was found to be the most cost-effective means of achieving the nominated campaign outcomes, followed by a combination of OV and OD and a combination of TV and OV. The use of TV in isolation was the least cost-effective.ConclusionThe results of this evaluation indicate that online media constitute a promising means of enhancing the cost-effectiveness of smoking cessation campaigns. Future research assessing a broader range of outcomes, especially smoking cessation, is needed to provide a more comprehensive account of the cost-effectiveness of various campaign media.

  19. Filmless versus film-based systems in radiographic examination costs: an activity-based costing method

    Directory of Open Access Journals (Sweden)

    Sase Yuji

    2011-09-01

    Full Text Available Abstract Background Since the shift from a radiographic film-based system to that of a filmless system, the change in radiographic examination costs and costs structure have been undetermined. The activity-based costing (ABC method measures the cost and performance of activities, resources, and cost objects. The purpose of this study is to identify the cost structure of a radiographic examination comparing a filmless system to that of a film-based system using the ABC method. Methods We calculated the costs of radiographic examinations for both a filmless and a film-based system, and assessed the costs or cost components by simulating radiographic examinations in a health clinic. The cost objects of the radiographic examinations included lumbar (six views, knee (three views, wrist (two views, and other. Indirect costs were allocated to cost objects using the ABC method. Results The costs of a radiographic examination using a filmless system are as follows: lumbar 2,085 yen; knee 1,599 yen; wrist 1,165 yen; and other 1,641 yen. The costs for a film-based system are: lumbar 3,407 yen; knee 2,257 yen; wrist 1,602 yen; and other 2,521 yen. The primary activities were "calling patient," "explanation of scan," "take photographs," and "aftercare" for both filmless and film-based systems. The cost of these activities cost represented 36.0% of the total cost for a filmless system and 23.6% of a film-based system. Conclusions The costs of radiographic examinations using a filmless system and a film-based system were calculated using the ABC method. Our results provide clear evidence that the filmless system is more effective than the film-based system in providing greater value services directly to patients.

  20. Filmless versus film-based systems in radiographic examination costs: an activity-based costing method.

    Science.gov (United States)

    Muto, Hiroshi; Tani, Yuji; Suzuki, Shigemasa; Yokooka, Yuki; Abe, Tamotsu; Sase, Yuji; Terashita, Takayoshi; Ogasawara, Katsuhiko

    2011-09-30

    Since the shift from a radiographic film-based system to that of a filmless system, the change in radiographic examination costs and costs structure have been undetermined. The activity-based costing (ABC) method measures the cost and performance of activities, resources, and cost objects. The purpose of this study is to identify the cost structure of a radiographic examination comparing a filmless system to that of a film-based system using the ABC method. We calculated the costs of radiographic examinations for both a filmless and a film-based system, and assessed the costs or cost components by simulating radiographic examinations in a health clinic. The cost objects of the radiographic examinations included lumbar (six views), knee (three views), wrist (two views), and other. Indirect costs were allocated to cost objects using the ABC method. The costs of a radiographic examination using a filmless system are as follows: lumbar 2,085 yen; knee 1,599 yen; wrist 1,165 yen; and other 1,641 yen. The costs for a film-based system are: lumbar 3,407 yen; knee 2,257 yen; wrist 1,602 yen; and other 2,521 yen. The primary activities were "calling patient," "explanation of scan," "take photographs," and "aftercare" for both filmless and film-based systems. The cost of these activities cost represented 36.0% of the total cost for a filmless system and 23.6% of a film-based system. The costs of radiographic examinations using a filmless system and a film-based system were calculated using the ABC method. Our results provide clear evidence that the filmless system is more effective than the film-based system in providing greater value services directly to patients.

  1. Repair and maintenance costs of 4WD tractors and self propelled combine harvesters in Italy

    Directory of Open Access Journals (Sweden)

    Aldo Calcante

    2013-09-01

    Full Text Available Purchasing and maintaining tractors and operating machines are two of the most considerable costs of the agricultural sector, which includes farm equipment manufacturers, farm contractors and farms. In this context, repair and maintenance costs (R&M costs generally constitute 10-15% of the total costs related to agricultural equipment and tend to increase with the age of the equipment; hence, an important consideration in farm management is the optimal time for equipment replacement. Classical, R&M cost estimation models, calculated as a function of accumulated working hours, are usually developed by ASAE/ASABE for the United States operating conditions. However, R&M costs are strongly influenced by farming practices, operative conditions, crop and soil type, climatic conditions, etc. which can be specific for individual countries. In this study, R&M cost model parameters were recalculated for the current Italian situation. For this purpose, data related to the R&M costs of 100 4WD tractors with engine power ranging from 59 to 198 kW, and of 20 SP combine harvesters (10 straw walkers combines and 10 axial flow combines with engine power ranging from 159 to 368 kW working in Italy were collected. According to the model, which was obtained by interpolating the data through a two-parameter power function (proposed by ASAE/ASABE, the R&M cost incidence on the list price of Italian tractors at 12,000 working hours (estimated life of the machines was 48.6%, as compared with 43.2% calculated through the most recent U.S. model while, for self propelled combine harvesters, the R&M cost incidence at 3,000 working hours was 23.1 % as compared with 40.2% calculated through the same U.S. model.

  2. FORMATION OF THE ENTERPRISE COSTS MANAGEMENT SYSTEM

    Directory of Open Access Journals (Sweden)

    Borysiuk Iryna

    2018-01-01

    Full Text Available Introduction. The paper deals with the actual issues of formation of the enterprise management system costs, because in the conditions of an unstable market environment the financial performance depends on the efficiency of the cost management system, competitiveness, financial sustainability and investment attractiveness of any subject of economic activity. Purpose of the article is consolidation of approaches to cost management, theoretical substantiation and development of recommendations regarding the formation of the enterprise cost management system. Results. Development of an enterprise cost management system based on research on the essence and cost management approaches. The goals, tasks, principles, methods, tools, functions and main elements of the cost management system were determined, factors of the external and internal environment of the enterprise, that affect the system of its costs management. Conclusions. Formation of integrated cost management system ensures the successful company operation on the market, production of competitive products based on costs and prices optimization and making a profit, increase of the reasonableness of making managerial decisions.

  3. Applicability and costs of nanofiltration in combination with photocatalysis for the treatment of dye house effluents

    Directory of Open Access Journals (Sweden)

    Wolfgang M. Samhaber

    2014-04-01

    Full Text Available Nanofiltration (NF is a capable method for the separation of dyes, which can support and even improve the applicability of photocatalysis in effluent-treatment processes. The membrane process usually will need a special pre-treatment to avoid precipitation and fouling on the membrane surface. Conceptually NF can be applied in the pre-treatment prior to the catalytic reactor or in connection with the reactor to separate the liquid phase from the reaction system and to recycle finely suspended catalysts and/or organic compounds. When concerning such reaction systems on a bigger scale, cost figures will prove the usefulness of those concepts. Different applications of photocatalysis on the lab-scale have been published in recent years. Membrane technology is used almost in all those processes and an overview will be given of those recently published systems that have been reported to be potentially useful for a further scale-up. NF membranes are mostly used for the more sophisticated separation step of these processes and the additional costs of the NF treatment, without any associated equipments, will be described and illustrated. The total specific costs of industrial NF treatment processes in usefully adjusted and designed plants range from 1 to 6 US$/m3 treated effluent. Combination concepts will have a good precondition for further development and upscaling, if the NF costs discussed here in detail will be, together with the costs of photocatalysis, economically acceptable.

  4. A cost-effectiveness analysis of fixed-combination therapies in patients with open-angle glaucoma: a European perspective.

    Science.gov (United States)

    Hommer, A; Wickstrøm, J; Friis, M M; Steeds, C; Thygesen, J; Ferreras, A; Gouws, P; Buchholz, P

    2008-04-01

    To compare the efficacy and cost implications of the use of the intraocular pressure-lowering prostaglandin analogues bimatoprost, travoprost, and latanoprost as fixed-combination therapies with timolol, a beta-adrenergic receptor antagonist. A decision analytic cost-effectiveness model was constructed. Since no head-to-head studies comparing the three treatment options exist, the analysis was based on an indirect comparison. Hence, the model was based on efficacy data from five randomized, controlled, clinical studies. The studies were comparable with respect to study design, time horizon, patient population and type of end point presented. The measure of effectiveness was the percentage reduction of the intraocular pressure level from baseline. The cost evaluated was the cost of medication and clinical visits to the ophthalmologist. All drug costs were market prices inclusive of value-added tax, and visit costs were priced using official physician fees. Cost-effectiveness analyses were carried out in five European countries: Spain, Italy, United Kingdom, Norway and Sweden. The time horizon for the analyses was 3 months. The analysis showed that fixed-combination bimatoprost/timolol was more effective and less costly than fixed-combination travoprost/timolol and fixed-combination latanoprost/timolol in three out of the five countries analyzed. In two countries, bimatoprost/timolol was less costly than latanoprost/timolol, and cost the same as travoprost/timolol. This cost-effectiveness analysis showed that the fixed combination of bimatoprost 0.03%/timolol 0.5% administered once daily was a cost-effective treatment option for patients with primary open-angle glaucoma. This study was limited by available clinical data: without a head-to-head trial, indirect comparisons were necessary. In the United Kingdom, Sweden, Norway, Italy, and Spain, from a health service viewpoint, bimatoprost/timolol was a slightly more effective as well as less costly treatment strategy

  5. Maintenance cost models in deregulated power systems under opportunity costs

    International Nuclear Information System (INIS)

    Al-Arfaj, K.; Dahal, K.; Azaiez, M.N.

    2007-01-01

    In a centralized power system, the operator is responsible for scheduling maintenance. There are different types of maintenance, including corrective maintenance; predictive maintenance; preventive maintenance; and reliability-centred maintenance. The main cause of power failures is poor maintenance. As such, maintenance costs play a significant role in deregulated power systems. They include direct costs associated with material and labor costs as well as indirect costs associated with spare parts inventory, shipment, test equipment, indirect labor, opportunity costs and cost of failure. In maintenance scheduling and planning, the cost function is the only component of the objective function. This paper presented the results of a study in which different components of maintenance costs were modeled. The maintenance models were formulated as an optimization problem with single and multiple objectives and a set of constraints. The maintenance costs models could be used to schedule the maintenance activities of power generators more accurately and to identify the best maintenance strategies over a period of time as they consider failure and opportunity costs in a deregulated environment. 32 refs., 4 tabs., 4 figs

  6. The costs of paying: Private and social costs of cash and card systems

    OpenAIRE

    Bergman, Mats; Guibourg, Gabriela; Segendorf, Björn

    2007-01-01

    Despite the central role of payments in theoretical and policy oriented economics, there is surprisingly little known about the costs of different payment instruments. We estimate social and private costs of cash, debit and credit card payments in Sweden in 2002. The combined social cost of providing these payment services is approximately 0.4 per cent of GDP. Debit and credit cards are socially less costly than cash for payments above EURO 8 and EURO 18, respectively. Corresponding threshold...

  7. A new costing model in hospital management: time-driven activity-based costing system.

    Science.gov (United States)

    Öker, Figen; Özyapıcı, Hasan

    2013-01-01

    Traditional cost systems cause cost distortions because they cannot meet the requirements of today's businesses. Therefore, a new and more effective cost system is needed. Consequently, time-driven activity-based costing system has emerged. The unit cost of supplying capacity and the time needed to perform an activity are the only 2 factors considered by the system. Furthermore, this system determines unused capacity by considering practical capacity. The purpose of this article is to emphasize the efficiency of the time-driven activity-based costing system and to display how it can be applied in a health care institution. A case study was conducted in a private hospital in Cyprus. Interviews and direct observations were used to collect the data. The case study revealed that the cost of unused capacity is allocated to both open and laparoscopic (closed) surgeries. Thus, by using the time-driven activity-based costing system, managers should eliminate the cost of unused capacity so as to obtain better results. Based on the results of the study, hospital management is better able to understand the costs of different surgeries. In addition, managers can easily notice the cost of unused capacity and decide how many employees to be dismissed or directed to other productive areas.

  8. Development of combined brake system on front and rear brakes for scooter; Scooter yo zenkorin rendo brake system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Okazaki, Y; Itabashi, T; Shinohara, S; Honda, Y [Honda R and D Co. Ltd., Tokyo (Japan)

    1997-10-01

    Scooters need appropriate front and rear wheel braking power distribution and each of front and rear brakes have been operated using right and left levers. This time, a low cost brakes with cable type combined brake system for small size scooter and a brakes with hydraulic type combined brake system for middle size scooter have been developed to obtain appropriate front and rear wheel braking power distribution. Both systems use convenient left lever to operate. 3 refs., 9 figs., 1 tab.

  9. The Compliance Cost of the U.S. Individual Income Tax System

    OpenAIRE

    Joel Slemrod; Nikki Sorum

    1984-01-01

    This paper uses evidence from a survey of Minnesota taxpayers to estimate the magnitude and demographic patterns of the compliance cost of filing federal and state income tax returns. It concludes that in 1982 this cost was between $17 and $27 billion, or from five to seven percent of the revenue raised by the federal and state income tax systems combined. About two billion hours of taxpayer time were spent on filing tax returns, and about $3 billion was spent on professional tax assistance.

  10. Distribution system costs associated with the deployment of photovoltaic systems

    Energy Technology Data Exchange (ETDEWEB)

    Horowitz, Kelsey A. W.; Palmintier, Bryan; Mather, Barry; Denholm, Paul

    2018-07-01

    The broadening of our energy system to include increasing amounts of wind and solar has led to significant debate about the total costs and benefits associated with different types of generators - with potentially far-reaching policy implications. This has included debate about the cost associated with integrating these generators onto the electric grid. For photovoltaics (PV), this encompasses costs incurred on both the bulk power and distribution systems, as well as the value provided to them. These costs and benefits, in particular those associated with integrating PV onto the distribution system, are not well understood. We seek to advance the state of understanding of 'grid integration costs' for the distribution system by reviewing prior literature and outlining a transparent, bottom-up approach that can be used to calculate these costs. We provide a clear delineation of costs to integrate PV in to the distribution system within the larger context of total costs and benefits associated with PV generators. We emphasize that these costs are situationally dependent, and that a single 'cost of integration' cannot be obtained. We additionally emphasize that benefits must be considered when evaluating the competitiveness of the technology in a given situation.

  11. Optimal operation of a micro-combined cooling, heating and power system driven by a gas engine

    International Nuclear Information System (INIS)

    Kong, X.Q.; Wang, R.Z.; Li, Y.; Huang, X.H.

    2009-01-01

    The objective of this paper is to investigate the problem of energy management and optimal operation of cogeneration system for micro-combined cooling, heating and power production (CCHP). The energy system mainly consists of a gas engine, an adsorption chiller, a gas boiler, a heat exchanger and an electric chiller. On the basis of an earlier experimental research of the micro-CCHP system, a non-linear-programming cost-minimization optimization model is presented to determine the optimum operational strategies for the system. It is shown that energy management and optimal operation of the micro-CCHP system is dependent upon load conditions to be satisfied and energy cost. In view of energy cost, it would not be optimal to operate the gas engine when the electric-to-gas cost ratio (EGCR) is very low. With higher EGCR, the optimum operational strategy of the micro-CCHP system is independent of energy cost

  12. Application of the exergetic cost theory to the LiBr/H2O vapour absorption system

    International Nuclear Information System (INIS)

    Misra, R.D.; Sahoo, P.K.; Gupta, A.

    2002-01-01

    Optimization of thermal systems is generally based on thermodynamic analysis. However, the systems so optimized often are not viable due to economic constraints. The Theory of Exergetic Cost, a thermoeconomic optimization technique, combines the thermodynamic analysis with that of economic constraints to obtain an optimum configuration of a thermal system. In this paper, this technique is applied to optimize a LiBr/H 2 O vapour absorption refrigeration system run by pressurized hot water for air-conditioning applications. The mathematical and numerical techniques-based optimization of thermal systems is not always possible due to plant complexities. Hence, a simplified cost minimization methodology, based on 'Theory of Exergetic Cost', is applied to evaluate the economic costs of all the internal flows and products of the system under consideration. As shown in this paper, once these costs are determined, an approximately optimum design configuration can be obtained

  13. Evaluation of Uniform Cost Accounting System to Fully Capture Depot Level Repair Costs.

    Science.gov (United States)

    1985-12-01

    RD-RI65 522 EVALUATION OF UNIFORM COST ACCOUNTING SYSTEM TO FULLY i/I CAPTURE DEPOT LEVEL REPAIR COSTS (U) NAVAL POSTGRADUATE SCHOOL MONTEREY CA D R...8217.LECTE B ,- THESIS EVALUATION OF UNIFORM COST ACCOUNTING SYSTEM 0TO FULLY CAPTURE DEPOT LEVEL REPAIR COSTS Jby __jDavid Richmond O’Brien lj,,, December...Include Security Classification) EVALUATION OF UNIFORM COST ACCOUNTING SYSTEM TO FULLY CAPTURE DEPOT LEVEL REPAIR COSTS 12 PERSONAL AUTHOR(S) O’Brien- David

  14. Multi-objective optimization and exergoeconomic analysis of a combined cooling, heating and power based compressed air energy storage system

    International Nuclear Information System (INIS)

    Yao, Erren; Wang, Huanran; Wang, Ligang; Xi, Guang; Maréchal, François

    2017-01-01

    Highlights: • A novel tri-generation based compressed air energy storage system. • Trade-off between efficiency and cost to highlight the best compromise solution. • Components with largest irreversibility and potential improvements highlighted. - Abstract: Compressed air energy storage technologies can improve the supply capacity and stability of the electricity grid, particularly when fluctuating renewable energies are massively connected. While incorporating the combined cooling, heating and power systems into compressed air energy storage could achieve stable operation as well as efficient energy utilization. In this paper, a novel combined cooling, heating and power based compressed air energy storage system is proposed. The system combines a gas engine, supplemental heat exchangers and an ammonia-water absorption refrigeration system. The design trade-off between the thermodynamic and economic objectives, i.e., the overall exergy efficiency and the total specific cost of product, is investigated by an evolutionary multi-objective algorithm for the proposed combined system. It is found that, with an increase in the exergy efficiency, the total product unit cost is less affected in the beginning, while rises substantially afterwards. The best trade-off solution is selected with an overall exergy efficiency of 53.04% and a total product unit cost of 20.54 cent/kWh, respectively. The variation of decision variables with the exergy efficiency indicates that the compressor, turbine and heat exchanger preheating the inlet air of turbine are the key equipment to cost-effectively pursuit a higher exergy efficiency. It is also revealed by an exergoeconomic analysis that, for the best trade-off solution, the investment costs of the compressor and the two heat exchangers recovering compression heat and heating up compressed air for expansion should be reduced (particularly the latter), while the thermodynamic performance of the gas engine need to be improved

  15. Integrated waste management system costs in a MPC system

    International Nuclear Information System (INIS)

    Supko, E.M.

    1995-01-01

    The impact on system costs of including a centralized interim storage facility as part of an integrated waste management system based on multi-purpose canister (MPC) technology was assessed in analyses by Energy Resources International, Inc. A system cost savings of $1 to $2 billion occurs if the Department of Energy begins spent fuel acceptance in 1998 at a centralized interim storage facility. That is, the savings associated with decreased utility spent fuel management costs will be greater than the cost of constructing and operating a centralized interim storage facility

  16. Operational strategy and marginal costs in simple trigeneration systems

    International Nuclear Information System (INIS)

    Lozano, M.A.; Carvalho, M.; Serra, L.M.

    2009-01-01

    As a direct result of economic pressures to cut expenses, as well as the legal obligation to reduce emissions, companies and businesses are seeking ways to use energy more efficiently. Trigeneration systems (CHCP: Combined Heating, Cooling and Power generation) allow greater operational flexibility at sites with a variable demand for energy in the form of heating and cooling. This is particularly relevant in buildings where the need for heating is restricted to a few winter months. In summer, the absorption chillers make use of the cogenerated heat to produce chilled water, avoiding waste heat discharge. The operation of a simple trigeneration system is analyzed in this paper. The system is interconnected to the electric utility grid, both to receive electricity and to deliver surplus electricity. For any given demand required by the users, a great number of operating conditions are possible. A linear programming model provides the operational mode with the lowest variable cost. A thermoeconomic analysis, based on marginal production costs, is used to obtain unit costs for internal energy flows and final products as well as to explain the best operational strategy as a function of the demand for energy services and the prices of the resources consumed. (author)

  17. Development of an accumulation-based system for cost-effective chamber measurements of inert trace gas fluxes

    DEFF Research Database (Denmark)

    Ambus, Per; Skiba, U.; Drewer, J.

    2010-01-01

    As soil–atmosphere fluxes of greenhouse gases are characterized by high temporal fluctuations, frequent measurements in the range of hours to days need to be deployed, resulting in high analytical costs. We have therefore developed a new low-cost system that combines high-frequency automated...

  18. Measure Guideline. Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation Industry Team (BSC), Somerville, MA (United States)

    2012-08-01

    This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

  19. Administration and transaction cost estimates for a greenhouse gas offset system : final report

    International Nuclear Information System (INIS)

    2004-01-01

    Canada's Climate Change Plan provides large final emitters (LFEs) with the option to meet their emission targets through the purchase of domestic greenhouse gas (GHG) offset credits. This paper presents the results of a study which identified and estimated transaction costs associated with an offset system. The cost to both proponents and governments were identified. The study also suggested ways to reduce administration and transaction costs through design options. The study considered projects involving agriculture, forests, landfill gas capture, renewable energy and energy efficiency within a potential domestic offset system. It was determined that average transaction costs per tonne range from $19 per tonne to $0.05 depending on the design choice and project type. Total administration costs did not vary more than 5 per cent between different design choices. The total system costs, which are the combination of all transaction and administration costs, are the best indicator for the potential of a project. Eight case studies were examined and costs per tonne were presented. According to the results, the best opportunities to reduce both transaction and administration costs are to choose a broad approach to baselines, boundaries and quantification; and, to allow pooling in the forestry and agriculture sectors. Transaction costs can be lowered further by reducing the frequency of monitoring and verification and allowing pre-2008 crediting. refs., tabs., figs

  20. Reliability and cost evaluation of small isolated power systems containing photovoltaic and wind energy

    Science.gov (United States)

    Karki, Rajesh

    Renewable energy application in electric power systems is growing rapidly worldwide due to enhanced public concerns for adverse environmental impacts and escalation in energy costs associated with the use of conventional energy sources. Photovoltaics and wind energy sources are being increasingly recognized as cost effective generation sources. A comprehensive evaluation of reliability and cost is required to analyze the actual benefits of utilizing these energy sources. The reliability aspects of utilizing renewable energy sources have largely been ignored in the past due the relatively insignificant contribution of these sources in major power systems, and consequently due to the lack of appropriate techniques. Renewable energy sources have the potential to play a significant role in the electrical energy requirements of small isolated power systems which are primarily supplied by costly diesel fuel. A relatively high renewable energy penetration can significantly reduce the system fuel costs but can also have considerable impact on the system reliability. Small isolated systems routinely plan their generating facilities using deterministic adequacy methods that cannot incorporate the highly erratic behavior of renewable energy sources. The utilization of a single probabilistic risk index has not been generally accepted in small isolated system evaluation despite its utilization in most large power utilities. Deterministic and probabilistic techniques are combined in this thesis using a system well-being approach to provide useful adequacy indices for small isolated systems that include renewable energy. This thesis presents an evaluation model for small isolated systems containing renewable energy sources by integrating simulation models that generate appropriate atmospheric data, evaluate chronological renewable power outputs and combine total available energy and load to provide useful system indices. A software tool SIPSREL+ has been developed which generates

  1. Composite decision support by combining cost-benefit and multi-criteria decision

    DEFF Research Database (Denmark)

    Barfod, Michael Bruhn; Salling, Kim Bang; Leleur, Steen

    2011-01-01

    This paper concerns composite decision support based on combining cost-benefit analysis (CBA) with multi-criteria decision analysis (MCDA) for the assessment of economic as well as strategic impacts within transport projects. Specifically a composite model for assessment (COSIMA) is presented...

  2. Cost optimization of a real-time GIS-based management system for hazardous waste transportation.

    Science.gov (United States)

    Zhu, Yun; Lin, Che-Jen; Zhong, Yilong; Zhou, Qing; Lin, Che-Jen; Chen, Chunyi

    2010-08-01

    In this paper, the design and cost analysis of a real-time, geographical information system (GIS) based management system for hazardous waste transportation are described. The implementation of such a system can effectively prevent illegal dumping and perform emergency responses during the transportation of hazardous wastes. A case study was conducted in Guangzhou, China to build a small-scale, real-time management system for waste transportation. Two alternatives were evaluated in terms of system capability and cost structure. Alternative I was the building of a complete real-time monitoring and management system in a governing agency; whereas alternative II was the combination of the existing management framework with a commercial Telematics service to achieve the desired level of monitoring and management. The technological framework under consideration included locating transportation vehicles using a global positioning system (GPS), exchanging vehicle location data via the Internet and Intranet, managing hazardous waste transportation using a government management system and responding to emergencies during transportation. Analysis of the cost structure showed that alternative II lowered the capital and operation cost by 38 and 56% in comparison with alternative I. It is demonstrated that efficient management can be achieved through integration of the existing technological components with additional cost benefits being achieved by streamlined software interfacing.

  3. Comprehensive analysis and parametric optimization of a CCP (combined cooling and power) system driven by geothermal source

    International Nuclear Information System (INIS)

    Zhao, Yajing; Wang, Jiangfeng; Cao, Liyan; Wang, Yu

    2016-01-01

    A CCP (combined cooling and power) system, which integrated a flash-binary power generation system with a bottom combined cooling and power subsystem operating through the combination of an organic Rankine cycle and an ejector refrigeration cycle, was developed to utilize geothermal energy. Thermodynamic and exergoeconomic analyses were performed on the system. A performance indicator, namely the average levelized costs per unit of exergy products for the overall system, was developed to assess the exergoeconomic performance of the system. The effects of four key parameters including flash pressure, pinch point temperature difference in the vapor generator, inlet pressure and back pressure of the ORC turbine on the system performance were evaluated through a parametric analysis. Two single-objective optimizations were conducted to reach the maximum exergy efficiency and the minimum average levelized costs per unit of exergy products for the overall system, respectively. The optimization results implied that the most exergoeconomically effective system couldn't obtain the best system thermodynamic performance and vice versa. An exergy analysis based on the thermodynamic optimization result revealed that the biggest exergy destruction occurred in the vapor generator and the next two largest exergy destruction were respectively caused by the steam turbine and the flashing device. - Highlights: • A CCP (combined cooling and power) system driven by geothermal source is developed. • Levelized costs per unit of exergy product is used as the exergoeconomic indicator. • Parametric analyses are performed from thermodynamic and exergoeconomic viewpoints. • The optimal exergoeconomic design cannot obtain the best thermodynamic performance. • Exergy analysis is carried out based on the thermodynamic optimization result.

  4. Comparison of costs for three hypothetical alternative kitchen waste management systems.

    Science.gov (United States)

    Schiettecatte, Wim; Tize, Ronald; De Wever, Heleen

    2014-11-01

    Urban water and waste management continues to be a major challenge, with the Earth's population projected to rise to 9 billion by 2050, with 70% of this population expected to live in cities. A combined treatment of wastewater and the organic fraction of municipal solid waste offers opportunities for improved environmental protection and energy recovery, but the collection and transport of organic wastes must be cost effective. This study compares three alternative kitchen waste collection and transportation systems for a virtual modern urban area with 300,000 residents and a population density of 10,000 persons per square kilometre. Door-to-door collection, being the standard practice in modern urban centres, remains the most economically advantageous at a cost of 263 euros per tonne of kitchen waste. Important drawbacks are the difficult logistics, increased city traffic, air and noise pollution. The quieter, cleaner and more hygienic vacuum transport of kitchen waste comes with a higher cost of 367 euros per tonne, mainly resulting from a higher initial investment cost for the system installation. The third option includes the well-known use of under-sink food waste disposers (often called garbage grinders) that are connected to the kitchen's wastewater piping system, with a total yearly cost of 392 euros per tonne. Important advantages with this system are the clean operation and the current availability of a city-wide sewage conveyance pipeline system. Further research is recommended, for instance the application of a life cycle assessment approach, to more fully compare the advantages and disadvantages of each option. © The Author(s) 2014.

  5. Mathematical modelling and optimization of a large-scale combined cooling, heat, and power system that incorporates unit changeover and time-of-use electricity price

    International Nuclear Information System (INIS)

    Zhu, Qiannan; Luo, Xianglong; Zhang, Bingjian; Chen, Ying

    2017-01-01

    Highlights: • We propose a novel superstructure for the design and optimization of LSCCHP. • A multi-objective multi-period MINLP model is formulated. • The unit start-up cost and time-of-use electricity prices are involved. • Unit size discretization strategy is proposed to linearize the original MINLP model. • A case study is elaborated to demonstrate the effectiveness of the proposed method. - Abstract: Building energy systems, particularly large public ones, are major energy consumers and pollutant emission contributors. In this study, a superstructure of large-scale combined cooling, heat, and power system is constructed. The off-design unit, economic cost, and CO_2 emission models are also formulated. Moreover, a multi-objective mixed integer nonlinear programming model is formulated for the simultaneous system synthesis, technology selection, unit sizing, and operation optimization of large-scale combined cooling, heat, and power system. Time-of-use electricity price and unit changeover cost are incorporated into the problem model. The economic objective is to minimize the total annual cost, which comprises the operation and investment costs of large-scale combined cooling, heat, and power system. The environmental objective is to minimize the annual global CO_2 emission of large-scale combined cooling, heat, and power system. The augmented ε–constraint method is applied to achieve the Pareto frontier of the design configuration, thereby reflecting the set of solutions that represent optimal trade-offs between the economic and environmental objectives. Sensitivity analysis is conducted to reflect the impact of natural gas price on the combined cooling, heat, and power system. The synthesis and design of combined cooling, heat, and power system for an airport in China is studied to test the proposed synthesis and design methodology. The Pareto curve of multi-objective optimization shows that the total annual cost varies from 102.53 to 94.59 M

  6. Using data from monitoring combined sewer overflows to assess, improve, and maintain combined sewer systems.

    Science.gov (United States)

    Montserrat, A; Bosch, Ll; Kiser, M A; Poch, M; Corominas, Ll

    2015-02-01

    Using low-cost sensors, data can be collected on the occurrence and duration of overflows in each combined sewer overflow (CSO) structure in a combined sewer system (CSS). The collection and analysis of real data can be used to assess, improve, and maintain CSSs in order to reduce the number and impact of overflows. The objective of this study was to develop a methodology to evaluate the performance of CSSs using low-cost monitoring. This methodology includes (1) assessing the capacity of a CSS using overflow duration and rain volume data, (2) characterizing the performance of CSO structures with statistics, (3) evaluating the compliance of a CSS with government guidelines, and (4) generating decision tree models to provide support to managers for making decisions about system maintenance. The methodology is demonstrated with a case study of a CSS in La Garriga, Spain. The rain volume breaking point from which CSO structures started to overflow ranged from 0.6 mm to 2.8 mm. The structures with the best and worst performance in terms of overflow (overflow probability, order, duration and CSO ranking) were characterized. Most of the obtained decision trees to predict overflows from rain data had accuracies ranging from 70% to 83%. The results obtained from the proposed methodology can greatly support managers and engineers dealing with real-world problems, improvements, and maintenance of CSSs. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Implementation of a low-cost, commercial orbit determination system

    Science.gov (United States)

    Corrigan, Jim

    1994-01-01

    Traditional satellite and launch control systems have consisted of custom solutions requiring significant development and maintenance costs. These systems have typically been designed to support specific program requirements and are expensive to modify and augment after delivery. The expanding role of space in today's marketplace combined with the increased sophistication and capabilities of modern satellites has created a need for more efficient, lower cost solutions to complete command and control systems. Recent technical advances have resulted in commercial-off-the-shelf products which greatly reduce the complete life-cycle costs associated with satellite launch and control system procurements. System integrators and spacecraft operators have, however, been slow to integrate these commercial based solutions into a comprehensive command and control system. This is due, in part, to a resistance to change and the fact that many available products are unable to effectively communicate with other commercial products. The United States Air Force, responsible for the health and safety of over 84 satellites via its Air Force Satellite Control Network (AFSCN), has embarked on an initiative to prove that commercial products can be used effectively to form a comprehensive command and control system. The initial version of this system is being installed at the Air Force's Center for Research Support (CERES) located at the National Test Facility in Colorado Springs, Colorado. The first stage of this initiative involved the identification of commercial products capable of satisfying each functional element of a command and control system. A significant requirement in this product selection criteria was flexibility and ability to integrate with other available commercial products. This paper discusses the functions and capabilities of the product selected to provide orbit determination functions for this comprehensive command and control system.

  8. ACTIVITY-BASED COSTING DAN SIMULATED ANNEALING UNTUK PENCARIAN RUTE PADA FLEXIBLE MANUFACTURING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Gregorius Satia Budhi

    2003-01-01

    Full Text Available Flexible Manufacturing System (FMS is a manufacturing system that is formed from several Numerical Controlled Machines combine with material handling system, so that different jobs can be worked by different machines sequences. FMS combine the high productivity and flexibility of Transfer Line and Job Shop manufacturing system. In this reasearch, Activity-Based Costing(ABC approach was used as the weight to search the operation route in the proper machine, so that the total production cost can be optimized. The search method that was used in this experiment is Simulated Annealling, a variant form Hill Climbing Search method. An ideal operation time to proses a part was used as the annealling schedule. From the empirical test, it could be proved that the use of ABC approach and Simulated Annealing to search the route (routing process can optimize the Total Production Cost. In the other hand, the use of ideal operation time to process a part as annealing schedule can control the processing time well. Abstract in Bahasa Indonesia : Flexible Manufacturing System (FMS adalah sistem manufaktur yang tersusun dari mesin-mesin Numerical Control (NC yang dikombinasi dengan Sistem Penanganan Material, sehingga job-job berbeda dikerjakan oleh mesin-mesin dengan alur yang berlainan. FMS menggabungkan produktifitas dan fleksibilitas yang tinggi dari Sistem Manufaktur Transfer Line dan Job Shop. Pada riset ini pendekatan Activity-Based Costing (ABC digunakan sebagai bobot / weight dalam pencarian rute operasi pada mesin yang tepat, untuk lebih mengoptimasi biaya produksi secara keseluruhan. Adapun metode Searching yang digunakan adalah Simulated Annealing yang merupakan varian dari metode searching Hill Climbing. Waktu operasi ideal untuk memproses sebuah part digunakan sebagai Annealing Schedulenya. Dari hasil pengujian empiris dapat dibuktikan bahwa penggunaan pendekatan ABC dan Simulated Annealing untuk proses pencarian rute (routing dapat lebih

  9. Stochastic analysis of residential micro combined heat and power system

    DEFF Research Database (Denmark)

    Karami, H.; Sanjari, M. J.; Gooi, H. B.

    2017-01-01

    In this paper the combined heat and power functionality of a fuel-cell in a residential hybrid energy system, including a battery, is studied. The demand uncertainties are modeled by investigating the stochastic load behavior by applying Monte Carlo simulation. The colonial competitive algorithm...... algorithm. The optimized scheduling of different energy resources is listed in an efficient look-up table for all time intervals. The effects of time of use and the battery efficiency and its size are investigated on the operating cost of the hybrid energy system. The results of this paper are expected...

  10. Emission operational strategy for combined cooling, heating, and power systems

    International Nuclear Information System (INIS)

    Fumo, Nelson; Mago, Pedro J.; Chamra, Louay M.

    2009-01-01

    Integrated Energy Systems (IES), as technology that use thermal activated components to recover waste heat, are energy systems that offer key solution to global warming and energy security through high overall energy efficiency and better fuel use. Combined Cooling, Heating, and Power (CCHP) Systems are IES that use recovered thermal energy from the prime mover to produce heating and cooling for the building. The CCHP operational strategy is critical and it has to be considered in a well designed system since it defines the ultimate goal for the benefits expected from the system. One of the most common operational strategies is the cost-oriented strategy, which allows the system to operate at the lowest cost. A primary energy strategy (PES) optimizes energy consumption instead of cost. However, as a result of the worldwide concern about global warming, projects that target reduction of greenhouse gas (GHG) emissions have gained a lot of interest. Therefore, for a CCHP system, an emission strategy (ES) would be an operational strategy oriented to minimize emission of pollutants. In this study, the use of an ES is proposed for CCHP systems targeted to reduce emission of pollutants. The primary energy consumption (PEC) reduction and carbon dioxide (CO 2 ) emission reduction obtained using the proposed ES are compared with results obtained from the use of a PES. Results show that lower emission of CO 2 is achieved with the ES when compared with the PES, which prove the advantage of the ES for the design of CCHP systems targeted to emissions reduction.

  11. The combined hybrid system: A symbiotic thermal reactor/fast reactor system for power generation and radioactive waste toxicity reduction

    International Nuclear Information System (INIS)

    Hollaway, W.R.

    1991-08-01

    If there is to be a next generation of nuclear power in the United States, then the four fundamental obstacles confronting nuclear power technology must be overcome: safety, cost, waste management, and proliferation resistance. The Combined Hybrid System (CHS) is proposed as a possible solution to the problems preventing a vigorous resurgence of nuclear power. The CHS combines Thermal Reactors (for operability, safety, and cost) and Integral Fast Reactors (for waste treatment and actinide burning) in a symbiotic large scale system. The CHS addresses the safety and cost issues through the use of advanced reactor designs, the waste management issue through the use of actinide burning, and the proliferation resistance issue through the use of an integral fuel cycle with co-located components. There are nine major components in the Combined Hybrid System linked by nineteen nuclear material mass flow streams. A computer code, CHASM, is used to analyze the mass flow rates CHS, and the reactor support ratio (the ratio of thermal/fast reactors), IFR of the system. The primary advantages of the CHS are its essentially actinide-free high-level radioactive waste, plus improved reactor safety, uranium utilization, and widening of the option base. The primary disadvantages of the CHS are the large capacity of IFRs required (approximately one MW e IFR capacity for every three MW e Thermal Reactor) and the novel radioactive waste streams produced by the CHS. The capability of the IFR to burn pure transuranic fuel, a primary assumption of this study, has yet to be proven. The Combined Hybrid System represents an attractive option for future nuclear power development; that disposal of the essentially actinide-free radioactive waste produced by the CHS provides an excellent alternative to the disposal of intact actinide-bearing Light Water Reactor spent fuel (reducing the toxicity based lifetime of the waste from roughly 360,000 years to about 510 years)

  12. New Approaches in Reuseable Booster System Life Cycle Cost Modeling

    Science.gov (United States)

    Zapata, Edgar

    2013-01-01

    This paper presents the results of a 2012 life cycle cost (LCC) study of hybrid Reusable Booster Systems (RBS) conducted by NASA Kennedy Space Center (KSC) and the Air Force Research Laboratory (AFRL). The work included the creation of a new cost estimating model and an LCC analysis, building on past work where applicable, but emphasizing the integration of new approaches in life cycle cost estimation. Specifically, the inclusion of industry processes/practices and indirect costs were a new and significant part of the analysis. The focus of LCC estimation has traditionally been from the perspective of technology, design characteristics, and related factors such as reliability. Technology has informed the cost related support to decision makers interested in risk and budget insight. This traditional emphasis on technology occurs even though it is well established that complex aerospace systems costs are mostly about indirect costs, with likely only partial influence in these indirect costs being due to the more visible technology products. Organizational considerations, processes/practices, and indirect costs are traditionally derived ("wrapped") only by relationship to tangible product characteristics. This traditional approach works well as long as it is understood that no significant changes, and by relation no significant improvements, are being pursued in the area of either the government acquisition or industry?s indirect costs. In this sense then, most launch systems cost models ignore most costs. The alternative was implemented in this LCC study, whereby the approach considered technology and process/practices in balance, with as much detail for one as the other. This RBS LCC study has avoided point-designs, for now, instead emphasizing exploring the trade-space of potential technology advances joined with potential process/practice advances. Given the range of decisions, and all their combinations, it was necessary to create a model of the original model

  13. New Approaches in Reusable Booster System Life Cycle Cost Modeling

    Science.gov (United States)

    Zapata, Edgar

    2013-01-01

    This paper presents the results of a 2012 life cycle cost (LCC) study of hybrid Reusable Booster Systems (RBS) conducted by NASA Kennedy Space Center (KSC) and the Air Force Research Laboratory (AFRL). The work included the creation of a new cost estimating model and an LCC analysis, building on past work where applicable, but emphasizing the integration of new approaches in life cycle cost estimation. Specifically, the inclusion of industry processes/practices and indirect costs were a new and significant part of the analysis. The focus of LCC estimation has traditionally been from the perspective of technology, design characteristics, and related factors such as reliability. Technology has informed the cost related support to decision makers interested in risk and budget insight. This traditional emphasis on technology occurs even though it is well established that complex aerospace systems costs are mostly about indirect costs, with likely only partial influence in these indirect costs being due to the more visible technology products. Organizational considerations, processes/practices, and indirect costs are traditionally derived ("wrapped") only by relationship to tangible product characteristics. This traditional approach works well as long as it is understood that no significant changes, and by relation no significant improvements, are being pursued in the area of either the government acquisition or industry?s indirect costs. In this sense then, most launch systems cost models ignore most costs. The alternative was implemented in this LCC study, whereby the approach considered technology and process/practices in balance, with as much detail for one as the other. This RBS LCC study has avoided point-designs, for now, instead emphasizing exploring the trade-space of potential technology advances joined with potential process/practice advances. Given the range of decisions, and all their combinations, it was necessary to create a model of the original model

  14. Development of cost-benefit analysis system

    International Nuclear Information System (INIS)

    Shiba, Tsuyoshi; Mishima, Tetsuya; Yuyama, Tomonori; Suzuki, Atsushi

    2001-01-01

    In order to promote the FDR development, it is necessary to see various benefits brought by introduction of FBR from multiple perspectives and have a good grasp of such benefits quantitatively and an adequate R and D investment scale which corresponds with them. In this study, the structured prototype in the previous study was improved to be able to perform cost-benefit analysis. An example of improvement made in the system is addition of subroutine used for comparison between new energy and benefits brought by introduction of FBR with special emphasis on addition of logic for analyzing externality about the new energy. Other improvement examples are modification of the Conventional Year Expense Ratio method of power generation cost to Average Durable Year Cost method, addition of database function and turning input data into database, and reviewing idea on cost by the type of waste material and price of uranium. The cost-benefit analysis system was also restructured utilizing Microsoft ACCESS so that it should have a data base function. As the result of the improvement mentioned above, we expect that the improved cost-benefit analysis system will have higher generality than the system before; therefore, great deal of benefits brought by application of the system in the future is expected. (author)

  15. A European perspective on costs and cost effectiveness of ophthalmic combinations in the treatment of open-angle glaucoma

    DEFF Research Database (Denmark)

    Hommer, A.; Thygesen, J.; Ferreras, A.

    2008-01-01

    PURPOSE: Efficacy, safety, and cost implications are important considerations when choosing an ophthalmic treatment. Fixed-combination glaucoma medications containing brimonidine 0.2% and timolol 0.5%, or dorzolamide 2% and timolol 0.5%, were compared with brimonidine 0.2% and dorzolamide 2...

  16. Cost Estimation and Control for Flight Systems

    Science.gov (United States)

    Hammond, Walter E.; Vanhook, Michael E. (Technical Monitor)

    2002-01-01

    Good program management practices, cost analysis, cost estimation, and cost control for aerospace flight systems are interrelated and depend upon each other. The best cost control process cannot overcome poor design or poor systems trades that lead to the wrong approach. The project needs robust Technical, Schedule, Cost, Risk, and Cost Risk practices before it can incorporate adequate Cost Control. Cost analysis both precedes and follows cost estimation -- the two are closely coupled with each other and with Risk analysis. Parametric cost estimating relationships and computerized models are most often used. NASA has learned some valuable lessons in controlling cost problems, and recommends use of a summary Project Manager's checklist as shown here.

  17. Planning uncertainties, market risks and new environmental choices: Winning least cost planning combinations

    International Nuclear Information System (INIS)

    Violette, D.; Lang, C.

    1990-01-01

    Utility demand and supply-side planners will face new challenges from environmental regulations. Under current proposals, every ton of pollutant will have a cost to utilities, not just the tons that put them over the allowable limit. Planners will have to account for these new costs. To do this, planners need to start tracking emissions implementation actions today, and begin strategies for future regulatory changes. Current legislative proposals include a tax on the carbon content of fuels to curb emissions of greenhouse gases and substantial reductions in sulfur dioxide and nitrogen oxide emissions. The important issue for planners is the flexible compliance requirements within these regulatory changes. The acid rain proposals, for example, include a market-based emissions trading system for emissions allowances. Whenever there is a competitive market, there are market risks, and potential winners and losers. Utilities need to be prepared to analyze and mitigate these risks. Integrated least cost planing is one way a utility will have to meet this challenge. Planning involves uncertainty and risk. The wide array of compliance choices create countless combinations of strategies for utilities to comply with the new emissions regulations. This paper discusses new compliance strategies, demand-side management (DSM) as a compliance strategy, solutions to DSM traps, and the compliance strategy game

  18. Cost-Effectiveness/Cost-Benefit Analysis of Newborn Screening for Severe Combined Immune Deficiency in Washington State.

    Science.gov (United States)

    Ding, Yao; Thompson, John D; Kobrynski, Lisa; Ojodu, Jelili; Zarbalian, Guisou; Grosse, Scott D

    2016-05-01

    To evaluate the expected cost-effectiveness and net benefit of the recent implementation of newborn screening (NBS) for severe combined immunodeficiency (SCID) in Washington State. We constructed a decision analysis model to estimate the costs and benefits of NBS in an annual birth cohort of 86 600 infants based on projections of avoided infant deaths. Point estimates and ranges for input variables, including the birth prevalence of SCID, proportion detected asymptomatically without screening through family history, screening test characteristics, survival rates, and costs of screening, diagnosis, and treatment were derived from published estimates, expert opinion, and the Washington NBS program. We estimated treatment costs stratified by age of identification and SCID type (with or without adenosine deaminase deficiency). Economic benefit was estimated using values of $4.2 and $9.0 million per death averted. We performed sensitivity analyses to evaluate the influence of key variables on the incremental cost-effectiveness ratio (ICER) of net direct cost per life-year saved. Our model predicts an additional 1.19 newborn infants with SCID detected preclinically through screening, in addition to those who would have been detected early through family history, and 0.40 deaths averted annually. Our base-case model suggests an ICER of $35 311 per life-year saved, and a benefit-cost ratio of either 5.31 or 2.71. Sensitivity analyses found ICER values <$100 000 and positive net benefit for plausible assumptions on all variables. Our model suggests that NBS for SCID in Washington is likely to be cost-effective and to show positive net economic benefit. Published by Elsevier Inc.

  19. [Progress in microalgae culture system for biodiesel combined with reducing carbon dioxide emission].

    Science.gov (United States)

    Su, Hongyang; Zhou, Xuefei; Xia, Xuefen; Sun, Zhen; Zhang, Yalei

    2011-09-01

    Wastewater resources, CO2 emission reduction and microalgae biodiesel are considered as current frontier fields of energy and environmental researches. In this paper, we reviewed the progress in system of microalgae culture for biodiesel production by wastewater and stack gas. Multiple factors including microalgal species, nutrition, culture methods and photobioreactor, which were crucial to the cultivation of microalgae for biodiesel production, were discussed in detail. A valuable culture system of microalgae for biodiesel production or other high value products combined with the treatment of wastewater by microalgae was put forward through the optimizations of algal species and culture technology. The culture system coupled with the treatment of wastewater, the reduction of CO2 emission with the cultivation of microalgae for biodiesel production will reduce the production cost of microalgal biofuel production and the treatment cost of wastewater simultaneously. Therefore, it would be a promising technology with important environmental value, social value and economic value to combine the treatment of wastewater with the cultivation of microalgae for biodiesel production.

  20. Cost benefit analysis of reactor safety systems

    International Nuclear Information System (INIS)

    Maurer, H.A.

    1984-01-01

    Cost/benefit analysis of reactor safety systems is a possibility appropriate to deal with reactor safety. The Commission of the European Communities supported a study on the cost-benefit or cost effectiveness of safety systems installed in modern PWR nuclear power plants. The following systems and their cooperation in emergency cases were in particular investigated in this study: the containment system (double containment), the leakage exhaust and control system, the annulus release exhaust system and the containment spray system. The benefit of a safety system is defined according to its contribution to the reduction of the radiological consequences for the environment after a LOCA. The analysis is so far performed in two different steps: the emergency core cooling system is considered to function properly, failure of the emergency core cooling system is assumed (with the possible consequence of core melt-down) and the results may demonstrate the evidence that striving for cost-effectiveness can produce a safer end result than the philosophy of safety at any cost. (orig.)

  1. Analysis of the total system life cycle cost for the Civilian Radioactive Waste Management Program

    International Nuclear Information System (INIS)

    1989-05-01

    The total-system life-cycle cost (TSLCC) analysis for the Department of Energy's (DOE) Civilian Radioactive Waste Management Program is an ongoing activity that helps determine whether the revenue-producing mechanism established by the Nuclear Waste Policy Act of 1982 -- a fee levied on electricity generated in commercial nuclear power plants -- is sufficient to cover the cost of the program. This report provides cost estimates for the sixth annual evaluation of the adequacy of the fee and is consistent with the program strategy and plans contained in the DOE's Draft 1988 Mission Plan Amendment. The total-system cost for the system with a repository at Yucca Mountain, Nevada, a facility for monitored retrievable storage (MRS), and a transportation system is estimated at $24 billion (expressed in constant 1988 dollars). In the event that a second repository is required and is authorized by the Congress, the total-system cost is estimated at $31 to $33 billion, depending on the quantity of spent fuel to be disposed of. The $7 billion cost savings for the single-repository system in comparison with the two-repository system is due to the elimination of $3 billion for second-repository development and $7 billion for the second-repository facility. These savings are offset by $2 billion in additional costs at the first repository and $1 billion in combined higher costs for the MRS facility and transportation. 55 refs., 2 figs., 24 tabs

  2. RodPilotR - The Innovative and Cost-Effective Digital Control Rod Drive Control System for PWRs

    International Nuclear Information System (INIS)

    Baron, Clemens

    2008-01-01

    With RodPilot, AREVA NP offers an innovative and cost-effective system for controlling control rods in Pressurized Water Reactors. RodPilot controls the three operating coils of the control rod drive mechanism (lift, moveable gripper and stationary gripper coil). The rods are inserted into or withdrawn from the core as required by the Reactor Control System. The system combines modern components, state-of-the-art logic and a proven electronic control rod drive control principle to provide enhanced reliability and lower maintenance costs. (author)

  3. A Modern Costing System: Activity Based Costing and An Application On A Textile Company

    OpenAIRE

    Titiz, İsmet; Altunay, Mehmet Akif

    2012-01-01

    The aim of this study is understanding Activity Based Costing which is one of the systems of modern cost approaches. Main concepts about activity based costing is defined and development of the system is identified. In the last part, an application about the activity based costing system in a textile company is explained and the results are analyzed.

  4. Cost-utility analysis of the fixed-dose combination of dolutegravir/abacavir/lamivudine as initial treatment of HIV+ patients in Spain

    Directory of Open Access Journals (Sweden)

    Santiago Moreno Guillen

    2017-09-01

    Full Text Available Objective: Fixed-dose combinations of antiretroviral drugs have meant an important step forward in simplifying treatment and improving compliance and has led to an increased effectiveness of therapy, a viral load decrease and improving the quality of life of patients. The single-table formulation of dolutegravir with abacavir and lamivudine (DTG/ABC/3TC is a highly efficacious and well-tolerated once-daily regimen for HIV-infected patients. The objective of the study was to assess the incremental cost-utility ratio of the fixed-dose combination of (DTG/ABC/3TC versus the combinations emtricitabine/tenofovir/efavirenz (FTC/TDF/EFV, and darunavir/r (DRV/r or raltegravir (RAL with emtricitabine/tenofovir (FTC/TDF or abacavir/lamivudine (ABC/3TC as initial antiretroviral therapy in patients infected with HIV-1 from the perspective of the Spanish National Health System. Method: The ARAMIS model, which uses a microsimulation approach to simulate the individual changes in each patient from the start of treatment to death through a Markov chain of descriptive health states of the disease, was adapted to Spain. The alternatives used for comparison were the fixed-dose combination of emtricitabine/tenofovir/efavirenz (FTC/TDF/EFV, and the fixed- dose combinations of emtricitabine/tenofovir (FTC/TDF or abacavir/lamivudine (ABC/3TC with darunavir/r (DRV/r or raltegravir (RAL. The probability of achieving virological suppression by the treatments included in the model was obtained from clinical trials SINGLE, SPRING-2 and FLAMINGO and the costs were expressed in € (2015. The model use the perspective of the Spanish National Health System, with a lifetime horizon and a discount rate of 3% was applied to cost and effectiveness. Results: Treatment initiation with DTG/ABC/3TC was dominant when it was compared with treatment initiation with all the comparators: vs. FTC/TDF/EFV (-67 210.71€/QALY, vs. DRV/r + FTC/TDF or ABC/3TC (-1 787 341.44€/QALY, and vs

  5. Stochastic analysis of residential micro combined heat and power system

    International Nuclear Information System (INIS)

    Karami, H.; Sanjari, M.J.; Gooi, H.B.; Gharehpetian, G.B.; Guerrero, J.M.

    2017-01-01

    Highlights: • Applying colonial competitive algorithm to the problem of optimal dispatching. • Economic modeling of the residential integrated energy system. • Investigating differences of stand-alone and system-connected modes of fuel cell operation. • Considering uncertainty on the electrical load. • The effects of battery capacity and its efficiency on the system is investigated. - Abstract: In this paper the combined heat and power functionality of a fuel-cell in a residential hybrid energy system, including a battery, is studied. The demand uncertainties are modeled by investigating the stochastic load behavior by applying Monte Carlo simulation. The colonial competitive algorithm is adopted to the hybrid energy system scheduling problem and different energy resources are optimally scheduled to have optimal operating cost of hybrid energy system. In order to show the effectiveness of the colonial competitive algorithm, the results are compared with the results of the harmony search algorithm. The optimized scheduling of different energy resources is listed in an efficient look-up table for all time intervals. The effects of time of use and the battery efficiency and its size are investigated on the operating cost of the hybrid energy system. The results of this paper are expected to be used effectively in a real hybrid energy system.

  6. A preliminary assessment of system cost impacts of using transportable storage casks and other shippable metal casks in the utility/DOE spent fuel management system

    International Nuclear Information System (INIS)

    Johnson, E.R.

    1988-01-01

    In view of the foregoing, a study was conducted by E.R. Johnson Associates, Inc. and H and R Technical Associates, Inc. to determine the prospective viability of the use of TSCs and shippable SOCs in the combined utility/DOE system. This study considered costs, ALARA considerations and the logistics of the use and delivery of casks to the DOE system by utilities. It was intended that this study would result in a technical and cost resource base that could be used for evaluating various strategies and scenarios for deploying TSCs or SOCs in the combined utility/DOE spent fuel management system with respect to the prospective economic advantage that could be realized

  7. From Consumption to Prosumption - Operational Cost Optimization for Refrigeration System With Heat Waste Recovery

    DEFF Research Database (Denmark)

    Minko, Tomasz; Garcia, Jesus Lago; Bendtsen, Jan Dimon

    2017-01-01

    Implementation of liquid cooling transforms a refrigeration system into a combined cooling and heating system. Reclaimed heat can be used for building heating purposes or can be sold. Carbon dioxide based refrigeration systems are considered to have a particularly high potential for becoming ecient...... heat energy producers. In this paper a CO2 system that operates in the subcritical region is examined. Modelling approach is presented, and used for operation optimisation by way of non-linear model predictive control techniques. Assuming that the heat is sold when using both objective functions......, it turns out that the system have negative operational cost. In case when Cost Minimization objective function is used daily revenue is about 7:9 [eur], for Prosumption one it is 11:9 [eur]....

  8. Principles and methods of managerial cost-accounting systems.

    Science.gov (United States)

    Suver, J D; Cooper, J C

    1988-01-01

    An introduction to cost-accounting systems for pharmacy managers is provided; terms are defined and examples of specific applications are given. Cost-accounting systems determine, record, and report the resources consumed in providing services. An effective cost-accounting system must provide the information needed for both internal and external reports. In accounting terms, cost is the value given up to secure an asset. In determining how volumes of activity affect costs, fixed costs and variable costs are calculated; applications include pricing strategies, cost determinations, and break-even analysis. Also discussed are the concepts of direct and indirect costs, opportunity costs, and incremental and sunk costs. For most pharmacy department services, process costing, an accounting of intermediate outputs and homogeneous units, is used; in determining the full cost of providing a product or service (e.g., patient stay), job-order costing is used. Development of work-performance standards is necessary for monitoring productivity and determining product costs. In allocating pharmacy department costs, a ratio of costs to charges can be used; this method is convenient, but microcosting (specific identification of the costs of products) is more accurate. Pharmacy managers can use cost-accounting systems to evaluate the pharmacy's strategies, policies, and services and to improve budgets and reports.

  9. Impact of Balance Of System (BOS) costs on photovoltaic power systems

    Science.gov (United States)

    Hein, G. F.; Cusick, J. P.; Poley, W. A.

    1978-01-01

    The Department of Energy has developed a program to effect a large reduction in the price of photovoltaic modules, with significant progress already achieved toward the 1986 goal of 50 cents/watt (1975 dollars). Remaining elements of a P/V power system (structure, battery storage, regulation, control, and wiring) are also significant cost items. The costs of these remaining elements are commonly referred to as Balance-of-System (BOS) costs. The BOS costs are less well defined and documented than module costs. The Lewis Research Center (LeRC) in 1976/77 and with two village power experiments that will be installed in 1978. The costs were divided into five categories and analyzed. A regression analysis was performed to determine correlations of BOS Costs per peak watt, with power size for these photovoltaic systems. The statistical relationship may be used for flat-plate, DC systems ranging from 100 to 4,000 peak watts. A survey of suppliers was conducted for comparison with the predicted BOS cost relationship.

  10. Costing improvement of remanufacturing crankshaft by integrating Mahalanobis-Taguchi System and Activity based Costing

    Science.gov (United States)

    Abu, M. Y.; Nor, E. E. Mohd; Rahman, M. S. Abd

    2018-04-01

    Integration between quality and costing system is very crucial in order to achieve an accurate product cost and profit. Current practice by most of remanufacturers, there are still lacking on optimization during the remanufacturing process which contributed to incorrect variables consideration to the costing system. Meanwhile, traditional costing accounting being practice has distortion in the cost unit which lead to inaccurate cost of product. The aim of this work is to identify the critical and non-critical variables during remanufacturing process using Mahalanobis-Taguchi System and simultaneously estimate the cost using Activity Based Costing method. The orthogonal array was applied to indicate the contribution of variables in the factorial effect graph and the critical variables were considered with overhead costs that are actually demanding the activities. This work improved the quality inspection together with costing system to produce an accurate profitability information. As a result, the cost per unit of remanufactured crankshaft of MAN engine model with 5 critical crankpins is MYR609.50 while Detroit engine model with 4 critical crankpins is MYR1254.80. The significant of output demonstrated through promoting green by reducing re-melting process of damaged parts to ensure consistent benefit of return cores.

  11. Costing the OMNIUM-G system 7500

    Science.gov (United States)

    Fortgang, H. R.

    1980-01-01

    A complete OMNIUM-G System 7500 was cost analyzed for annual production quantities ranging from 25 to 10,000 units per year. Parts and components were subjected to in-depth scrutiny to determine optimum manufacturing processes, coupled with make or buy decisions on materials and small parts. When production quantities increase both labor and material costs reduce substantially. A redesign of the system that was analyzed could result in lower costs when annual production runs approach 100,000 units/year. Material and labor costs for producing 25, 100, 25,000 and 100,00 units are given for 17 subassembly units.

  12. Separate and combined sewer systems: a long-term modelling approach.

    Science.gov (United States)

    Mannina, Giorgio; Viviani, Gaspare

    2009-01-01

    Sewer systems convey mostly dry weather flow, coming from domestic and industrial sanitary sewage as well as infiltration flow, and stormwater due to meteoric precipitations. Traditionally, in urban drainage two types of sewer systems are adopted: separate and combined sewers. The former convey dry and wet weather flow separately into two different networks, while the latter convey dry and wet weather flow together. Which is the best solution in terms of cost-benefit analysis still remains a controversial subject. The present study was aimed at comparing the pollution loads discharged to receiving bodies by Wastewater Treatment Plant (WWTP) and Combined Sewer Overflow (CSO) for different kinds of sewer systems (combined and separate). To accomplish this objective, a comparison between the two systems was carried out using results from simulations of catchments characterised by different dimensions, population densities and water supply rate. The analysis was based on a parsimonious mathematical model able to simulate the sewer system as well as the WWTP during both dry and wet weather. The rain series employed for the simulations was six years long. Several pollutants, both dissolved and particulate, were modelled. The results confirmed the uncertainties in the choice of one system versus the other, emphasising the concept that case-by-case solutions have to be undertaken. Further, the compared systems showed different responses in terms of effectiveness in reducing the discharged mass to the RWB in relation to the particular pollutant taken into account.

  13. Cost estimates for near-term depolyment of advanced traffic management systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, S.S.; Chin, S.M.

    1993-02-15

    The objective of this study is to provide cost est engineering, design, installation, operation and maintenance of Advanced Traffic Management Systems (ATMS) in the largest 75 metropolitan areas in the United States. This report gives estimates for deployment costs for ATMS in the next five years, subject to the qualifications and caveats set out in following paragraphs. The report considers infrastructure components required to realize fully a functional ATMS over each of two highway networks (as discussed in the Section describing our general assumptions) under each of the four architectures identified in the MITRE Intelligent Vehicle Highway Systems (IVHS) Architecture studies. The architectures are summarized in this report in Table 2. Estimates are given for eight combinations of highway networks and architectures. We estimate that it will cost between $8.5 Billion (minimal network) and $26 Billion (augmented network) to proceed immediately with deployment of ATMS in the largest 75 metropolitan areas. Costs are given in 1992 dollars, and are not adjusted for future inflation. Our estimates are based partially on completed project costs, which have been adjusted to 1992 dollars. We assume that a particular architecture will be chosen; projected costs are broken by architecture.

  14. Cost and performance analysis of physical security systems

    International Nuclear Information System (INIS)

    Hicks, M.J.; Yates, D.; Jago, W.H.

    1997-01-01

    CPA - Cost and Performance Analysis - is a prototype integration of existing PC-based cost and performance analysis tools: ACEIT (Automated Cost Estimating Integrated Tools) and ASSESS (Analytic System and Software for Evaluating Safeguards and Security). ACE is an existing DOD PC-based tool that supports cost analysis over the full life cycle of a system; that is, the cost to procure, operate, maintain and retire the system and all of its components. ASSESS is an existing DOE PC-based tool for analysis of performance of physical protection systems. Through CPA, the cost and performance data are collected into Excel workbooks, making the data readily available to analysts and decision makers in both tabular and graphical formats and at both the system and subsystem levels. The structure of the cost spreadsheets incorporates an activity-based approach to cost estimation. Activity-based costing (ABC) is an accounting philosophy used by industry to trace direct and indirect costs to the products or services of a business unit. By tracing costs through security sensors and procedures and then mapping the contributions of the various sensors and procedures to system effectiveness, the CPA architecture can provide security managers with information critical for both operational and strategic decisions. The architecture, features and applications of the CPA prototype are presented. 5 refs., 3 figs

  15. Analysis of a combined heating and cooling system model under different operating strategies

    Science.gov (United States)

    Dzierzgowski, Mieczysław; Zwierzchowski, Ryszard

    2017-11-01

    The paper presents an analysis of a combined heating and cooling system model under different operating strategies. Cooling demand for air conditioning purposes has grown steadily in Poland since the early 1990s. The main clients are large office buildings and shopping malls in downtown locations. Increased demand for heat in the summer would mitigate a number of problems regarding District Heating System (DHS) operation at minimum power, affecting the average annual price of heat (in summertime the share of costs related to transport losses is a strong cost factor). In the paper, computer simulations were performed for different supply network water temperature, assuming as input, real changes in the parameters of the DHS (heat demand, flow rates, etc.). On the basis of calculations and taking into account investment costs of the Absorption Refrigeration System (ARS) and the Thermal Energy Storage (TES) system, an optimal capacity of the TES system was proposed to ensure smooth and efficient operation of the District Heating Plant (DHP). Application of ARS with the TES system in the DHS in question increases net profit by 19.4%, reducing the cooling price for consumers by 40%.

  16. PLACE OF PRODUCTION COSTS SYSTEM ANALYSIS IN SYSTEM ANALYSIS

    Directory of Open Access Journals (Sweden)

    Mariia CHEREDNYCHENKO

    2016-12-01

    Full Text Available Current economic conditions require the development and implementation of an adequate system of production costs, which would ensure a steady profit growth and production volumes in a highly competitive, constantly increasing input prices and tariffs. This management system must be based on an integrated production costs system analysis (PCSA, which would provide all operating costs management subsystems necessary information to design and make better management decisions. It provides a systematic analysis of more opportunities in knowledge, creating conditions of integrity mechanism knowledge object consisting of elements that show intersystem connections, each of which has its own defined and limited objectives, relationship with the environment.

  17. Multi-dimensional project evaluation: Combining cost-benefit analysis and multi-criteria analysis with the COSIMA software system

    DEFF Research Database (Denmark)

    and not the least construction and maintenance costs. The MCA is made use of to assess noise, land use planning, business potential and tourism impacts for the three alternatives. More technically the software system offers a set of different features to undertake the MCA. Thus the users have two different methods...... for society is ranked uppermost. To compare the different impacts, it is necessary to have a common monetary unit. Theoretically, all benefits and all costs should be accounted for in socio-economic cost-benefit analysis. However, this is far from in practical the general case due to difficulties...... in a valuating all the criteria in monetary terms. Thus CBA does not meet the need for a comprehensive evaluation, for which reason MCA is introduced to overcome this problem. Not only does MCA provides an opportunity to include non-market impacts in the analysis, but MCA also provides a framework for breaking...

  18. Renewables, nuclear, or fossil fuels? Scenarios for Great Britain’s power system considering costs, emissions and energy security

    International Nuclear Information System (INIS)

    Pfenninger, Stefan; Keirstead, James

    2015-01-01

    Highlights: • We compare a large number of cost-optimal future power systems for Great Britain. • Scenarios are assessed on cost, emissions reductions, and energy security. • Up to 60% of variable renewable capacity is possible with little cost increase. • Higher shares require storage, imports or dispatchable renewables such as tidal range. - Abstract: Mitigating climate change is driving the need to decarbonize the electricity sector, for which various possible technological options exist, alongside uncertainty over which options are preferable in terms of cost, emissions reductions, and energy security. To reduce this uncertainty, we here quantify two questions for the power system of Great Britain (England, Wales and Scotland): First, when compared within the same high-resolution modeling framework, how much do different combinations of technologies differ in these three respects? Second, how strongly does the cost and availability of grid-scale storage affect overall system cost, and would it favor some technology combinations above others? We compare three main possible generation technologies: (1) renewables, (2) nuclear, and (3) fossil fuels (with/without carbon capture and storage). Our results show that across a wide range of these combinations, the overall costs remain similar, implying that different configurations are equally feasible both technically and economically. However, the most economically favorable scenarios are not necessarily favorable in terms of emissions or energy security. The availability of grid-scale storage in scenarios with little dispatchable generation can reduce overall levelized electricity cost by up to 50%, depending on storage capacity costs. The UK can rely on its domestic wind and solar PV generation at lower renewable shares, with levelized costs only rising more than 10% above the mean of 0.084 GBP/kWh for shares of 50% and below at a 70% share, which is 35% higher. However, for more than an 80% renewable

  19. Least cost analysis of Belarus electricity generation system with focus on nuclear option

    International Nuclear Information System (INIS)

    Mikhalevich, A.; Yakushau, A.

    2004-01-01

    accepted in Russia for NPP placement sites. The result of the preliminary studies had shown that there are at least three suitable sites for construction of the NPP. It allows including nuclear power option in the list of possible technologies for electricity generation. Optimal expansion plan of the electricity generation system based on installation new combine cycle units, co-generation units and nuclear power plants has been developed. Optimal least cost expansion plan has been chosen as a result of comparative analysis of the three scenarios: Scenario 1: Steam turbine, Combined cycle, Gas turbine, Co-generation turbine, Natural gas; Scenario 2: Steam turbine, Combined cycle, Gas turbine, Co-generation turbine, Natural gas, Coal; Scenario 3: Steam turbine, Combined cycle, Gas turbine, Co-generation turbine, Natural gas, Nuclear. Using WASP III plus computer code optimal electricity generation system expansion plan for each scenario had been found. Calculations had been carried out for discount rate equaled 8 %. The results of calculation are shown that electricity system expansion plan based on utilization of coal as a fuel has highest generation cost. Otherwise, implementation on nuclear power will allow decreasing generation cost up to 3.26 cents/kWh. In accordance with calculation optimal solution includes construction four nuclear units and first unit has to start up in 2014 year. For Scenario based on natural gas and nuclear fuel mix is expected to be least total electricity generation cost and it is most economically attractive option.(author)

  20. Analysis of the location for peak heating in CHP based combined district heating systems

    International Nuclear Information System (INIS)

    Wang, Haichao; Lahdelma, Risto; Wang, Xin; Jiao, Wenling; Zhu, Chuanzhi; Zou, Pinghua

    2015-01-01

    Combined heat and power (CHP) is the main technology for providing the base load of district heating in China. However, CHP is not efficient for providing the peak load; instead, a peak boiler with high efficiency could be used to compensate the peak load. This paper studies how the location of the peak boiler can affect the energy efficiency and economic performance of such CHP based combined district heating system. Firstly, the connection mode and the control strategy for different peak heating locations are analyzed. Then the effect of the peak boiler's location on the initial investment of the network and the cost for distributing heat is studied. The objective is to place the peak boiler in a location where the overall costs are the smallest. Following this rule, the results indicate that the peak boiler should be located at the CHP plant if that allows using cheaper ‘self-use electricity’ in CHP for distributing the heat. However, if the market electricity price is used everywhere, or if energy efficiency is more emphasized, the location of the peak boiler should be closer to the users with dense heat loads. - Highlights: • Location for peak heating in the CHP based combined DH system is studied. • Regulation or control strategies for combined DH are summarized. • The heat load duration curve for combined DH is demonstrated. • Network design for combined DH with peak boiler outside of the CHP is analyzed

  1. Incremental cost analysis of advanced concept CAES systems

    Energy Technology Data Exchange (ETDEWEB)

    Knutsen, C.A.

    1979-09-01

    The costs of compressed air energy storage (CAES) systems using thermal energy storage (TES) are compared to the costs of CAES systems without TES and simple cycle gas turbine systems. Comparisons are made in terms of the system energy costs levelized over the operating life of the systems. These are in 1985 price levels which is the assumed first year of operation for the systems.

  2. Implementation of a Cost-Accounting System for Visibility of Weapon Systems Life-Cycle Costs

    National Research Council Canada - National Science Library

    Ugone, Mary

    2001-01-01

    .... The DoD Acquisition Reform Goal 10 required DoD to define requirements and establish an implementation plan for a cost-accounting system that provides routine visibility into weapon system life-cycle...

  3. External costs and taxes in heat supply systems

    International Nuclear Information System (INIS)

    Karlsson, Aasa; Gustavsson, Leif

    2003-01-01

    A systems approach was used to compare different heating systems from a consumer perspective. The whole energy system was considered from natural resources to the required energy services. District heating, electric heat pumps, electric boilers, natural-gas-, oil- or pellet-fired local boilers were considered when supplying heat to a detached house. The district heat production included wood-chip-fired and natural-gas-fired cogeneration plants. Electricity other than cogenerated electricity was produced in wood-chip- and natural-gas-fired stand-alone power plants. The analysis includes four tax scenarios, as well as the external cost of environmental and health damage arising from energy conversion emission based on the ExternE study of the European Commission. The most cost-efficient systems were the natural-gas and oil boiler systems, followed by the heat pump and district heating systems, when the external cost and taxes were excluded. When including the external costs of CO 2 emission, the wood-fuel-based systems were much more cost efficient than the fossil-fuel-based systems, also when CO 2 capture and storage were applied. The external costs are, however, highly uncertain. Taxes steer towards lowering energy use and lowering CO 2 emission if they are levied solely on all the fossil-fuel-related emission and fuel use in the systems. If consumer electricity and heat taxes are used, the taxes have an impact on the total cost, regardless of the fuel used, thereby benefiting fuel-based local heating systems. The heat pump systems were the least affected by taxes, due to their high energy efficiency. The electric boiler systems were the least cost-efficient systems, also when the external cost and taxes were included

  4. Selected Tether Applications Cost Model

    Science.gov (United States)

    Keeley, Michael G.

    1988-01-01

    Diverse cost-estimating techniques and data combined into single program. Selected Tether Applications Cost Model (STACOM 1.0) is interactive accounting software tool providing means for combining several independent cost-estimating programs into fully-integrated mathematical model capable of assessing costs, analyzing benefits, providing file-handling utilities, and putting out information in text and graphical forms to screen, printer, or plotter. Program based on Lotus 1-2-3, version 2.0. Developed to provide clear, concise traceability and visibility into methodology and rationale for estimating costs and benefits of operations of Space Station tether deployer system.

  5. RodPilot{sup R} - The Innovative and Cost-Effective Digital Control Rod Drive Control System for PWRs

    Energy Technology Data Exchange (ETDEWEB)

    Baron, Clemens [AREVA NP GmbH, NLEE-G, Postfach 1199, 91001 Erlangen (Germany)

    2008-07-01

    With RodPilot, AREVA NP offers an innovative and cost-effective system for controlling control rods in Pressurized Water Reactors. RodPilot controls the three operating coils of the control rod drive mechanism (lift, moveable gripper and stationary gripper coil). The rods are inserted into or withdrawn from the core as required by the Reactor Control System. The system combines modern components, state-of-the-art logic and a proven electronic control rod drive control principle to provide enhanced reliability and lower maintenance costs. (author)

  6. High efficiency pump combiner fabricated by CO2 laser splicing system

    Science.gov (United States)

    Zhu, Gongwen

    2018-02-01

    High power combiners are of great interest for high power fiber lasers and fiber amplifiers. With the advent of CO2 laser splicing system, power combiners are made possible with low manufacturing cost, low loss, high reliability and high performance. Traditionally fiber optical components are fabricated with flame torch, electrode arc discharge or filament heater. However, these methods can easily leave contamination on the fiber, resulting inconsistent performance or even catching fire in high power operations. The electrodes or filaments also degrade rapidly during the combiner manufacturing process. The rapid degradation will lead to extensive maintenance, making it unpractical or uneconomic for volume production. By contrast, CO2 laser is the cleanest heating source which provides reliable and repeatable process for fabricating fiber optic components including high power combiners. In this paper we present an all fiber end pumped 7x1 pump combiner fabricated by CO2 laser splicing system. The input pump fibers are 105/125 (core/clad diameters in μm) fibers with a core NA of 0.22. The output fiber is a 300/320 fiber with a core NA of 0.22. The average efficiency is 99.4% with all 7 ports more than 99%. The process is contamination-free and highly repeatable. To our best knowledge, this is the first report in the literature on power combiners fabricated by CO2 laser splicing system. It also has the highest reported efficiency of its kind.

  7. Activity-Based Costing Systems for Higher Education.

    Science.gov (United States)

    Day, Dennis H.

    1993-01-01

    Examines traditional costing models utilized in higher education and pinpoints shortcomings related to proper identification of costs. Describes activity-based costing systems as a superior alternative for cost identification, measurement, and allocation. (MLF)

  8. Cost analysis of an integrated vaccine-preventable disease surveillance system in Costa Rica.

    Science.gov (United States)

    Toscano, C M; Vijayaraghavan, M; Salazar-Bolaños, H M; Bolaños-Acuña, H M; Ruiz-González, A I; Barrantes-Solis, T; Fernández-Vargas, I; Panero, M S; de Oliveira, L H; Hyde, T B

    2013-07-02

    Following World Health Organization recommendations set forth in the Global Framework for Immunization Monitoring and Surveillance, Costa Rica in 2009 became the first country to implement integrated vaccine-preventable disease (iVPD) surveillance, with support from the U.S. Centers for Disease Control and Prevention (CDC) and the Pan American Health Organization (PAHO). As surveillance for diseases prevented by new vaccines is integrated into existing surveillance systems, these systems could cost more than routine surveillance for VPDs targeted by the Expanded Program on Immunization. We estimate the costs associated with establishing and subsequently operating the iVPD surveillance system at a pilot site in Costa Rica. We retrospectively collected data on costs incurred by the institutions supporting iVPD surveillance during the preparatory (January 2007 through August 2009) and implementation (September 2009 through August 2010) phases of the iVPD surveillance project in Costa Rica. These data were used to estimate costs for personnel, meetings, infrastructure, office equipment and supplies, transportation, and laboratory facilities. Costs incurred by each of the collaborating institutions were also estimated. During the preparatory phase, the estimated total cost was 128,000 U.S. dollars (US$), including 64% for personnel costs. The preparatory phase was supported by CDC and PAHO. The estimated cost for 1 year of implementation was US$ 420,000, including 58% for personnel costs, 28% for laboratory costs, and 14% for meeting, infrastructure, office, and transportation costs combined. The national reference laboratory and the PAHO Costa Rica office incurred 64% of total costs, and other local institutions supporting iVPD surveillance incurred the remaining 36%. Countries planning to implement iVPD surveillance will require adequate investments in human resources, laboratories, data management, reporting, and investigation. Our findings will be valuable for

  9. A new accounting system for financial balance based on personnel cost after the introduction of a DPC/DRG system.

    Science.gov (United States)

    Nakagawa, Yoshiaki; Takemura, Tadamasa; Yoshihara, Hiroyuki; Nakagawa, Yoshinobu

    2011-04-01

    A hospital director must estimate the revenues and expenses not only in a hospital but also in each clinical division to determine the proper management strategy. A new prospective payment system based on the Diagnosis Procedure Combination (DPC/PPS) introduced in 2003 has made the attribution of revenues and expenses for each clinical department very complicated because of the intricate involvement between the overall or blanket component and a fee-for service (FFS). Few reports have so far presented a programmatic method for the calculation of medical costs and financial balance. A simple method has been devised, based on personnel cost, for calculating medical costs and financial balance. Using this method, one individual was able to complete the calculations for a hospital which contains 535 beds and 16 clinics, without using the central hospital computer system.

  10. Combinations of Methods for Collaborative Evaluation of the Usability of Interactive Software Systems

    Directory of Open Access Journals (Sweden)

    Andrés Solano

    2016-01-01

    Full Text Available Usability is a fundamental quality characteristic for the success of an interactive system. It is a concept that includes a set of metrics and methods in order to obtain easy-to-learn and easy-to-use systems. Usability Evaluation Methods, UEM, are quite diverse; their application depends on variables such as costs, time availability, and human resources. A large number of UEM can be employed to assess interactive software systems, but questions arise when deciding which method and/or combination of methods gives more (relevant information. We propose Collaborative Usability Evaluation Methods, CUEM, following the principles defined by the Collaboration Engineering. This paper analyzes a set of CUEM conducted on different interactive software systems. It proposes combinations of CUEM that provide more complete and comprehensive information about the usability of interactive software systems than those evaluation methods conducted independently.

  11. Cost-effectiveness analysis of a voucher scheme combined with obstetrical quality improvements: quasi experimental results from Uganda.

    Science.gov (United States)

    Alfonso, Y Natalia; Bishai, David; Bua, John; Mutebi, Aloysius; Mayora, Crispus; Ekirapa-Kiracho, Elizabeth

    2015-02-01

    The maternal mortality ratio (MMR) in Uganda has declined significantly during the last 20 years, but Uganda is not on track to reach the millennium development goal of reducing MMR by 75% by 2015. More evidence on the cost-effectiveness of supply- and demand-side financing programs to reduce maternal mortality could inform future strategies. This study analyses the cost-effectiveness of a voucher scheme (VS) combined with health system strengthening in rural Uganda against the status quo. The VS, implemented in 2010, provided vouchers for delivery services at public and private health facilities (HF), as well as round-trip transportation provided by private sector workers (bicycles or motorcycles generally). The VS was part of a quasi-experimental non-randomized control trial. Improvements in institutional delivery coverage (IDC) rates can be estimated using a difference-in-difference impact evaluation method and the number of maternal lives saved is modelled using the evidence-based Lives Saved Tool. Costs were estimated from primary and secondary data. Results show that the demand for births at HFs enrolled in the VS increased by 52.3 percentage points. Out of this value, conservative estimates indicate that at least 9.4 percentage points are new HF users. This 9.4% bump in IDC implies 20 deaths averted, which is equivalent to 1356 disability-adjusted-life years (DALYs) averted. Cost-effectiveness analysis comparing the status quo and VS's most conservative effectiveness estimates shows that the VS had an incremental cost-effectiveness ratio per DALY averted of US$302 and per death averted of US$20 756. Although there are limitations in the data measures, a favourable cost-effectiveness ratio persists even under extreme assumptions. Demand-side vouchers combined with supply-side financing programs can increase attended deliveries and reduce maternal mortality at a cost that is acceptable. Published by Oxford University Press in association with The London School

  12. Consequential environmental and economic life cycle assessment of green and gray stormwater infrastructures for combined sewer systems.

    Science.gov (United States)

    Wang, Ranran; Eckelman, Matthew J; Zimmerman, Julie B

    2013-10-01

    A consequential life cycle assessment (LCA) is conducted to evaluate the trade-offs between water quality improvements and the incremental climate, resource, and economic costs of implementing green (bioretention basin, green roof, and permeable pavement) versus gray (municipal separate stormwater sewer systems, MS4) alternatives of stormwater infrastructure expansions against a baseline combined sewer system with combined sewer overflows in a typical Northeast US watershed for typical, dry, and wet years. Results show that bioretention basins can achieve water quality improvement goals (e.g., mitigating freshwater eutrophication) for the least climate and economic costs of 61 kg CO2 eq. and $98 per kg P eq. reduction, respectively. MS4 demonstrates the minimum life cycle fossil energy use of 42 kg oil eq. per kg P eq. reduction. When integrated with the expansion in stormwater infrastructure, implementation of advanced wastewater treatment processes can further reduce the impact of stormwater runoff on aquatic environment at a minimal environmental cost (77 kg CO2 eq. per kg P eq. reduction), which provides support and valuable insights for the further development of integrated management of stormwater and wastewater. The consideration of critical model parameters (i.e., precipitation intensity, land imperviousness, and infrastructure life expectancy) highlighted the importance and implications of varying local conditions and infrastructure characteristics on the costs and benefits of stormwater management. Of particular note is that the impact of MS4 on the local aquatic environment is highly dependent on local runoff quality indicating that a combined system of green infrastructure prior to MS4 potentially provides a more cost-effective improvement to local water quality.

  13. Sizing Combined Heat and Power Units and Domestic Building Energy Cost Optimisation

    Directory of Open Access Journals (Sweden)

    Dongmin Yu

    2017-06-01

    Full Text Available Many combined heat and power (CHP units have been installed in domestic buildings to increase energy efficiency and reduce energy costs. However, inappropriate sizing of a CHP may actually increase energy costs and reduce energy efficiency. Moreover, the high manufacturing cost of batteries makes batteries less affordable. Therefore, this paper will attempt to size the capacity of CHP and optimise daily energy costs for a domestic building with only CHP installed. In this paper, electricity and heat loads are firstly used as sizing criteria in finding the best capacities of different types of CHP with the help of the maximum rectangle (MR method. Subsequently, the genetic algorithm (GA will be used to optimise the daily energy costs of the different cases. Then, heat and electricity loads are jointly considered for sizing different types of CHP and for optimising the daily energy costs through the GA method. The optimisation results show that the GA sizing method gives a higher average daily energy cost saving, which is 13% reduction compared to a building without installing CHP. However, to achieve this, there will be about 3% energy efficiency reduction and 7% input power to rated power ratio reduction compared to using the MR method and heat demand in sizing CHP.

  14. Development and application of performance and cost models for the externally-fired combined cycle. Task 1, Volume 2. Topical report, June 1995

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, P.; Frey, H. [North Carolina State Univ., Raleigh, NC (United States); Rubin, E.S. [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    1995-07-01

    Increasing restrictions on emission of pollutants from conventional pulverized coal fired steam (PCFS) plant generating electrical power is raising capital and operating cost of these plants and at the same time lowering plant efficiency. This is creating a need for alternative technologies which result in lower emissions of regulated pollutants and which are thermally more efficient. Natural gas-fired combined cycle power generation systems have lower capital cost and higher efficiencies than conventional coal fired steam plants, and at this time they are the leading contender for new power plant construction in the U.S. But the intermediate and long term cost of these fuels is high and there is uncertainty regarding their long-term price and availability. Coal is a relatively low cost fuel which will be abundantly available in the long term. This has motivated the development of advanced technologies for power production from coal which will have advantages of other fuels. The Externally Fired Combined Cycle (EFCC) is one such technology. Air pollution control/hot gas cleanup issues associated with this technology are described.

  15. Development of a Low-cost, Comprehensive Recording System for Circadian Rhythm Behavior.

    Science.gov (United States)

    Kwon, Jea; Park, Min Gu; Lee, Seung Eun; Lee, C Justin

    2018-02-01

    Circadian rhythm is defined as a 24-hour biological oscillation, which persists even without any external cues but also can be re-entrained by various environmental cues. One of the widely accepted circadian rhythm behavioral experiment is measuring the wheel-running activity (WRA) of rodents. However, the price for commercially available WRA recording system is not easily affordable for researchers due to high-cost implementation of sensors for wheel rotation. Here, we developed a cost-effective and comprehensive system for circadian rhythm recording by measuring the house-keeping activities (HKA). We have monitored animal's HKA as electrical signal by simply connecting animal housing cage with a standard analog/digital converter: input to the metal lid and ground to the metal grid floor. We show that acquired electrical signals are combined activities of eating, drinking and natural locomotor behaviors which are well-known indicators of circadian rhythm. Post-processing of measured electrical signals enabled us to draw actogram, which verifies HKA to be reliable circadian rhythm indicator. To provide easy access of HKA recording system for researchers, we have developed user-friendly MATLAB-based software, Circa Analysis. This software provides functions for easy extraction of scalable "touch activity" from raw data files by automating seven steps of post-processing and drawing actograms with highly intuitive user-interface and various options. With our cost-effective HKA circadian rhythm recording system, we have estimated the cost of our system to be less than $150 per channel. We anticipate our system will benefit many researchers who would like to study circadian rhythm.

  16. Effects of a shortened depreciation schedule on the investment costs for combined heat and power; TOPICAL

    International Nuclear Information System (INIS)

    Kranz, Nicole; Worrell, Ernst

    2001-01-01

    We investigate and compare several generic depreciation methods to assess the effectiveness of possible policy measures with respect to the depreciation schedules for investments in combined heat and power plants in the United States. We assess the different depreciation methods for CHP projects of various sizes (ranging from 1 MW to 100 MW). We evaluate the impact of different depreciation schedules on the tax shield, and the resulting tax savings to potential investors. We show that a shorter depreciation cycle could have a substantial impact on the cost of producing power, making cogeneration more attractive. The savings amount to approximately 6-7 percent of capital and fixed operation and maintenance costs, when changing from the current system to a 7 year depreciation scheme with switchover from declining balance to straight line depreciation. Suggestions for further research to improve the analysis are given

  17. Techniques for cost-effective electric information sharing; Cost balance wo koryoshita denshi joho kyoyuka gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, Y. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1997-04-01

    The key technology that can effectively support the sharing of each information such as documents, data, and know-how was rearranged to clarify how to utilize it for constructing an electronic information sharing system. The key technology that supports the sharing of electronic information was rearranged from the viewpoint of information gathering, information rearrangement, and information utilization. The reduction in cost for information gathering and rearrangement is indispensable to the promotion of much information sharing. However, each automation method presently causes the deterioration in quality of the rearranged information and the increase in cost for information utilization. To realize a practical electronic information sharing system, it is important to combine the key technologies properly so that the total cost balance of information gathering and information utilization is improved. Therefore, the combination of character recognition by OCR and unpreciseness retrieval, and the complementary combination of automatic document sorting, based on multiple incomplete rearrangement systems, and multiple sorting menus were proposed. 23 refs., 5 figs., 2 tabs.

  18. The Added Economic and Environmental Value of Solar Thermal Systems in Microgrids with CombinedHeat and Power

    Energy Technology Data Exchange (ETDEWEB)

    Marnay, Chris; Stadler, Michael; Cardoso, Goncalo; Megel, Olivier; Lai, Judy; Siddiqui, Afzal

    2009-08-15

    The addition of solar thermal and heat storage systems can improve the economic, as well as environmental attraction of micro-generation systems, e.g. fuel cells with or without combined heat and power (CHP) and contribute to enhanced CO2 reduction. However, the interactions between solar thermal collection and storage systems and CHP systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of solar thermal and heat storage on CO2 emissions and annual energy costs, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program. The objective is minimization of annual energy costs. This paper focuses on analysis of the optimal interaction of solar thermal systems, which can be used for domestic hot water, space heating and/or cooling, and micro-CHP systems in the California service territory of San Diego Gas and Electric (SDG&E). Contrary to typical expectations, our results indicate that despite the high solar radiation in southern California, fossil based CHP units are dominant, even with forecast 2020 technology and costs. A CO2 pricing scheme would be needed to incent installation of combined solar thermal absorption chiller systems, and no heat storage systems are adopted. This research also shows that photovoltaic (PV) arrays are favored by CO2 pricing more than solar thermal adoption.

  19. The Added Economic and Environmental Value of Solar Thermal Systems in Microgrids with CombinedHeat and Power

    International Nuclear Information System (INIS)

    Marnay, Chris; Stadler, Michael; Cardoso, Goncalo; Megel, Olivier; Lai, Judy; Siddiqui, Afzal

    2009-01-01

    The addition of solar thermal and heat storage systems can improve the economic, as well as environmental attraction of micro-generation systems, e.g. fuel cells with or without combined heat and power (CHP) and contribute to enhanced CO2 reduction. However, the interactions between solar thermal collection and storage systems and CHP systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of solar thermal and heat storage on CO2 emissions and annual energy costs, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program. The objective is minimization of annual energy costs. This paper focuses on analysis of the optimal interaction of solar thermal systems, which can be used for domestic hot water, space heating and/or cooling, and micro-CHP systems in the California service territory of San Diego Gas and Electric (SDG and amp;E). Contrary to typical expectations, our results indicate that despite the high solar radiation in southern California, fossil based CHP units are dominant, even with forecast 2020 technology and costs. A CO2 pricing scheme would be needed to incent installation of combined solar thermal absorption chiller systems, and no heat storage systems are adopted. This research also shows that photovoltaic (PV) arrays are favored by CO2 pricing more than solar thermal adoption.

  20. Gas fired combined cycle plant in Singapore: energy use, GWP and cost-a life cycle approach

    International Nuclear Information System (INIS)

    Kannan, R.; Leong, K.C.; Osman, Ramli; Ho, H.K.; Tso, C.P.

    2005-01-01

    A life cycle assessment was performed to quantify the non-renewable (fossil) energy use and global warming potential (GWP) in electricity generation from a typical gas fired combined cycle power plant in Singapore. The cost of electricity generation was estimated using a life cycle cost analysis (LCCA) tool. The life cycle assessment (LCA) of a 367.5 MW gas fired combined cycle power plant operating in Singapore revealed that hidden processes consume about 8% additional energy in addition to the fuel embedded energy, and the hidden GWP is about 18%. The natural gas consumed during the operational phase accounted for 82% of the life cycle cost of electricity generation. An empirical relation between plant efficiency and life cycle energy use and GWP in addition to a scenario for electricity cost with varying gas prices and plant efficiency have been established

  1. Modifications to Replacement Costs System

    International Nuclear Information System (INIS)

    Godec, M.

    1989-01-01

    The purpose of this memorandum is to document the improvements and modifications made to the Replacement Costs of Crude Oil (REPCO) Supply Analysis System. While some of this work was performed under our previous support contract to DOE/ASFE, we are presenting all modifications and improvements are presented here for completeness. The memo primarily documents revisions made to the Lower-48 Onshore Model. Revisions and modifications made to other components and models in the REPCO system which are documented elsewhere are only highlighted in this memo. Generally, the modifications made to the Lower-48 Onshore Model reflect changes that have occurred in domestic drilling, oil field costs, and reserves since 1982, the date of the most recent available data used for the original Replacement Costs report, published in 1985

  2. A microbial fuel cell–membrane bioreactor integrated system for cost-effective wastewater treatment

    International Nuclear Information System (INIS)

    Wang, Yong-Peng; Liu, Xian-Wei; Li, Wen-Wei; Li, Feng; Wang, Yun-Kun; Sheng, Guo-Ping; Zeng, Raymond J.; Yu, Han-Qing

    2012-01-01

    Highlights: ► An MFC–MBR integrated system for wastewater treatment and electricity generation. ► Stable electricity generation during 1000-h continuous operation. ► Low-cost electrode, separator and filter materials were adopted. -- Abstract: Microbial fuel cell (MFC) and membrane bioreactor (MBR) are both promising technologies for wastewater treatment, but both with limitations. In this study, a novel MFC–MBR integrated system, which combines the advantages of the individual systems, was proposed for simultaneous wastewater treatment and energy recovery. The system favored a better utilization of the oxygen in the aeration tank of MBR by the MFC biocathode, and enabled a high effluent quality. Continuous and stable electricity generation, with the average current of 1.9 ± 0.4 mA, was achieved over a long period of about 40 days. The maximum power density reached 6.0 W m −3 . Moreover, low-cost materials were used for the reactor construction. This integrated system shows great promise for practical wastewater treatment application.

  3. The cost of systemic therapy for metastatic colorectal carcinoma in Slovenia: discrepancy analysis between cost and reimbursement

    International Nuclear Information System (INIS)

    Mesti, Tanja; Boshkoska, Biljana Mileva; Kos, Mitja; Tekavčič, Metka; Ocvirk, Janja

    2015-01-01

    The aim of the study was to estimate the direct medical costs of metastatic colorectal cancer (mCRC) treated at the Institute of Oncology Ljubljana and to question the healthcare payment system in Slovenia. Using an internal patient database, the costs of mCRC patients were estimated in 2009 by examining (1) mCRC direct medical related costs, and (2) the cost difference between payment received by Slovenian health insurance and actual mCRC costs. Costs were analysed in the treatment phase of the disease by assessing the direct medical costs of hospital treatment with systemic therapy together with hospital treatment of side effects, without assessing radiotherapy or surgical treatment. Follow-up costs, indirect medical costs, and nonmedical costs were not included. A total of 209 mCRC patients met all eligibility criteria. The direct medical costs of mCRC hospitalization with systemic therapy in Slovenia for 2009 were estimated as the cost of medications (cost of systemic therapy + cost of drugs for premedication) + labor cost (the cost of carrying out systemic treatment) + cost of lab tests + cost of imaging tests + KRAS testing cost + cost of hospital treatment due to side effects of mCRC treatment, and amounted to €3,914,697. The difference between the cost paid by health insurance and actual costs, estimated as direct medical costs of hospitalization of mCRC patients treated with systemic therapy at the Institute of Oncology Ljubljana in 2009, was €1,900,757.80. The costs paid to the Institute of Oncology Ljubljana by health insurance for treating mCRC with systemic therapy do not match the actual cost of treatment. In fact, the difference between the payment and the actual cost estimated as direct medical costs of hospitalization of mCRC patients treated with systemic therapy at the Institute of Oncology Ljubljana in 2009 was €1,900,757.80. The model Australian Refined Diagnosis Related Groups (AR-DRG) for cost assessment in oncology being currently used

  4. Cost-benefit analysis for combined heat and power plant

    International Nuclear Information System (INIS)

    Sazdovski, Ace; Fushtikj, Vangel

    2004-01-01

    The paper presents a methodology and practical application of Cost-Benefit Analysis for Combined Heat and Power Plant (Cogeneration facility). Methodology include up-to-date and real data for cogeneration plant in accordance with the trends ill development of the CHP technology. As a case study a CHP plant that could be built-up in Republic of Macedonia is analyzed. The main economic parameters for project evaluation, such as NPV and IRR are calculated for a number of possible scenarios. The analyze present the economic outputs that could be used as a decision for CHP project acceptance for investment. (Author)

  5. Cost-Effectiveness of Nivolumab-Ipilimumab Combination Therapy Compared with Monotherapy for First-Line Treatment of Metastatic Melanoma in the United States.

    Science.gov (United States)

    Oh, Anna; Tran, Dang M; McDowell, Leann C; Keyvani, Dor; Barcelon, Jay Andrew; Merino, Oscar; Wilson, Leslie

    2017-06-01

    The approval of new immunotherapies has dramatically changed the treatment landscape of metastatic melanoma. These survival gains come with trade-offs in side effects and costs, as well as important considerations for third-party payer systems, physicians, and patients. To develop a Markov model to determine the cost-effectiveness of nivolumab, ipilimumab, and nivolumab-ipilimumab combination as firstline therapy in metastatic melanoma, while accounting for differential effectiveness in programmed death-ligand 1 (PD-L1) positive and negative patients. A 3-state Markov model (PD-L1 positive stable disease, PD-L1 negative stable disease, and progression and/or death) was developed using a U.S. societal perspective with a lifetime time horizon of 14.5 years. Transition probabilities were calculated from progression-free (PF) survival data reported in the CheckMate-067 trial. Costs were expressed in 2015 U.S. dollars and were determined using national sources. Adverse event (AE) management was determined using immune-related AE (irAE) data from CheckMate-067, irAE management guides for nivolumab and ipilimumab, and treatment guidelines. Utilities were obtained from published literature, using melanoma-specific studies when available, and were weighted based on incidence and duration of irAEs. Base case, one-way sensitivity, and probabilistic sensitivity analyses were conducted. Nivolumab-ipilimumab combination therapy was not the cost-effective choice ($454,092 per PF quality-adjusted life-year [QALY]) compared with nivolumab monotherapy in a base case analysis at a willingness-to-pay threshold of $100,000 per PFQALY. Combination therapy and nivolumab monotherapy were cost-effective choices compared with ipilimumab monotherapy. PD-L1 positive status, utility of nivolumab and combination therapy, and medication costs contributed the most uncertainty to the model. In a population of 100% PD-L1 negative patients, nivolumab was still the optimal treatment, but combination

  6. Video distribution system cost model

    Science.gov (United States)

    Gershkoff, I.; Haspert, J. K.; Morgenstern, B.

    1980-01-01

    A cost model that can be used to systematically identify the costs of procuring and operating satellite linked communications systems is described. The user defines a network configuration by specifying the location of each participating site, the interconnection requirements, and the transmission paths available for the uplink (studio to satellite), downlink (satellite to audience), and voice talkback (between audience and studio) segments of the network. The model uses this information to calculate the least expensive signal distribution path for each participating site. Cost estimates are broken downy by capital, installation, lease, operations and maintenance. The design of the model permits flexibility in specifying network and cost structure.

  7. Cost effectiveness of recycling: A systems model

    Energy Technology Data Exchange (ETDEWEB)

    Tonjes, David J., E-mail: david.tonjes@stonybrook.edu [Department of Technology and Society, College of Engineering and Applied Sciences, Stony Brook University, Stony Brook, NY 11794-3560 (United States); Waste Reduction and Management Institute, School of Marine and Atmospheric Sciences, Stony Brook University, Stony Brook, NY 11794-5000 (United States); Center for Bioenergy Research and Development, Advanced Energy Research and Technology Center, Stony Brook University, 1000 Innovation Rd., Stony Brook, NY 11794-6044 (United States); Mallikarjun, Sreekanth, E-mail: sreekanth.mallikarjun@stonybrook.edu [Department of Technology and Society, College of Engineering and Applied Sciences, Stony Brook University, Stony Brook, NY 11794-3560 (United States)

    2013-11-15

    Highlights: • Curbside collection of recyclables reduces overall system costs over a range of conditions. • When avoided costs for recyclables are large, even high collection costs are supported. • When avoided costs for recyclables are not great, there are reduced opportunities for savings. • For common waste compositions, maximizing curbside recyclables collection always saves money. - Abstract: Financial analytical models of waste management systems have often found that recycling costs exceed direct benefits, and in order to economically justify recycling activities, externalities such as household expenses or environmental impacts must be invoked. Certain more empirically based studies have also found that recycling is more expensive than disposal. Other work, both through models and surveys, have found differently. Here we present an empirical systems model, largely drawn from a suburban Long Island municipality. The model accounts for changes in distribution of effort as recycling tonnages displace disposal tonnages, and the seven different cases examined all show that curbside collection programs that manage up to between 31% and 37% of the waste stream should result in overall system savings. These savings accrue partially because of assumed cost differences in tip fees for recyclables and disposed wastes, and also because recycling can result in a more efficient, cost-effective collection program. These results imply that increases in recycling are justifiable due to cost-savings alone, not on more difficult to measure factors that may not impact program budgets.

  8. Spaceborne construction and operations planning - Decision rules for selecting EVA, telerobot, and combined work-systems

    Science.gov (United States)

    Smith, Jeffrey H.

    1992-01-01

    An approach is presented for selecting an appropriate work-system for performing construction and operations tasks by humans and telerobots. The decision to use extravehicular activity (EVA) performed by astronauts, extravehicular robotics (EVR), or a combination of EVA and EVR is determined by the ratio of the marginal costs of EVA, EVR, and IVA. The approach proposed here is useful for examining cost trade-offs between tasks and performing trade studies of task improvement techniques (human or telerobotic).

  9. Optimal Medical Equipment Maintenance Service Proposal Decision Support System combining Activity Based Costing (ABC) and the Analytic Hierarchy Process (AHP).

    Science.gov (United States)

    da Rocha, Leticia; Sloane, Elliot; M Bassani, Jose

    2005-01-01

    This study describes a framework to support the choice of the maintenance service (in-house or third party contract) for each category of medical equipment based on: a) the real medical equipment maintenance management system currently used by the biomedical engineering group of the public health system of the Universidade Estadual de Campinas located in Brazil to control the medical equipment maintenance service, b) the Activity Based Costing (ABC) method, and c) the Analytic Hierarchy Process (AHP) method. Results show the cost and performance related to each type of maintenance service. Decision-makers can use these results to evaluate possible strategies for the categories of equipment.

  10. 1?10 kW Stationary Combined Heat and Power Systems Status and Technical Potential: Independent Review

    Energy Technology Data Exchange (ETDEWEB)

    Maru, H. C.; Singhal, S. C.; Stone, C.; Wheeler, D.

    2010-11-01

    This independent review examines the status and technical potential of 1-10 kW stationary combined heat and power fuel cell systems and analyzes the achievability of the DOE cost, efficiency, and durability targets for 2012, 2015, and 2020.

  11. COST EFFECTIVE VOC EMISSION CONTROL STARTEGIES FOR MILITARY, AEROSPACE,AND INDUSTRIAL PAINT SPRAY BOOTH OPERATIONS: COMBINING IMPROVED VENTILATION SYSTEMS WITH INNOVATIVE, LOW COST EMISSION CONTROL TECHNOLOGIES

    Science.gov (United States)

    The paper describes a full-scale demonstration program in which several paint booths were modified for recirculation ventilation; the booth exhaust streams are vented to an innovative volatile organic compound (VOC) emission control system having extremely low operating costs. ...

  12. SCATS: SRB Cost Accounting and Tracking System handbook

    Science.gov (United States)

    Zorv, R. B.; Stewart, R. D.; Coley, G.; Higginbotham, M.

    1978-01-01

    The Solid Rocket Booster Cost Accounting and Tracking System (SCATS) which is an automatic data processing system designed to keep a running account of the number, description, and estimated cost of Level 2, 3, and 4 changes is described. Although designed specifically for the Space Shuttle Solid Rocket Booster Program, the ADP system can be used for any other program that has a similar structure for recording, reporting, and summing numbers and costs of changes. The program stores the alpha-numeric designators for changes, government estimated costs, proposed costs, and negotiated value in a MIRADS (Marshall Information Retrieval and Display System) format which permits rapid access, manipulation, and reporting of current change status. Output reports listing all changes, totals of each level, and totals of all levels, can be derived for any calendar interval period.

  13. Analysis of costs-benefits tradeoffs of complex security systems

    International Nuclear Information System (INIS)

    Hicks, M.J.

    1996-01-01

    Essential to a systems approach to design of security systems is an analysis of the cost effectiveness of alternative designs. While the concept of analysis of costs and benefits is straightforward, implementation can be at the least tedious and, for complex designs and alternatives, can become nearly intractable without the help of structured analysis tools. PACAIT--Performance and Cost Analysis Integrated Tools--is a prototype tool. The performance side of the analysis collates and reduces data from ASSESS, and existing DOE PC-based security systems performance analysis tool. The costs side of the analysis uses ACE, an existing DOD PC-based costs analysis tool. Costs are reported over the full life-cycle of the system, that is, the costs to procure, operate, maintain and retire the system and all of its components. Results are collected in Microsoft reg-sign Excel workbooks and are readily available to analysts and decision makers in both tabular and graphical formats and at both the system and path-element levels

  14. No Cost – Low Cost Compressed Air System Optimization in Industry

    Science.gov (United States)

    Dharma, A.; Budiarsa, N.; Watiniasih, N.; Antara, N. G.

    2018-04-01

    Energy conservation is a systematic, integrated of effort, in order to preserve energy sources and improve energy utilization efficiency. Utilization of energy in efficient manner without reducing the energy usage it must. Energy conservation efforts are applied at all stages of utilization, from utilization of energy resources to final, using efficient technology, and cultivating an energy-efficient lifestyle. The most common way is to promote energy efficiency in the industry on end use and overcome barriers to achieve such efficiency by using system energy optimization programs. The facts show that energy saving efforts in the process usually only focus on replacing tools and not an overall system improvement effort. In this research, a framework of sustainable energy reduction work in companies that have or have not implemented energy management system (EnMS) will be conducted a systematic technical approach in evaluating accurately a compressed-air system and potential optimization through observation, measurement and verification environmental conditions and processes, then processing the physical quantities of systems such as air flow, pressure and electrical power energy at any given time measured using comparative analysis methods in this industry, to provide the potential savings of energy saving is greater than the component approach, with no cost to the lowest cost (no cost - low cost). The process of evaluating energy utilization and energy saving opportunities will provide recommendations for increasing efficiency in the industry and reducing CO2 emissions and improving environmental quality.

  15. Low cost metamodel for robust design of periodic nonlinear coupled micro-systems

    Directory of Open Access Journals (Sweden)

    Chikhaoui K.

    2016-01-01

    Full Text Available To achieve robust design, in presence of uncertainty, nonlinearity and structural periodicity, a metamodel combining the Latin Hypercube Sampling (LHS method for uncertainty propagation and an enriched Craig-Bampton Component Mode Synthesis approach (CB-CMS for model reduction is proposed. Its application to predict the time responses of a stochastic periodic nonlinear micro-system proves its efficiency in terms of accuracy and reduction of computational cost.

  16. Cost optimization for buildings with hybrid ventilation systems

    Science.gov (United States)

    Ji, Kun; Lu, Yan

    2018-02-13

    A method including: computing a total cost for a first zone in a building, wherein the total cost is equal to an actual energy cost of the first zone plus a thermal discomfort cost of the first zone; and heuristically optimizing the total cost to identify temperature setpoints for a mechanical heating/cooling system and a start time and an end time of the mechanical heating/cooling system, based on external weather data and occupancy data of the first zone.

  17. Need for Cost Optimization of Space Life Support Systems

    Science.gov (United States)

    Jones, Harry W.; Anderson, Grant

    2017-01-01

    As the nation plans manned missions that go far beyond Earth orbit to Mars, there is an urgent need for a robust, disciplined systems engineering methodology that can identify an optimized Environmental Control and Life Support (ECLSS) architecture for long duration deep space missions. But unlike the previously used Equivalent System Mass (ESM), the method must be inclusive of all driving parameters and emphasize the economic analysis of life support system design. The key parameter for this analysis is Life Cycle Cost (LCC). LCC takes into account the cost for development and qualification of the system, launch costs, operational costs, maintenance costs and all other relevant and associated costs. Additionally, an effective methodology must consider system technical performance, safety, reliability, maintainability, crew time, and other factors that could affect the overall merit of the life support system.

  18. Development of an EVA systems cost model. Volume 3: EVA systems cost model

    Science.gov (United States)

    1975-01-01

    The EVA systems cost model presented is based on proposed EVA equipment for the space shuttle program. General information on EVA crewman requirements in a weightless environment and an EVA capabilities overview are provided.

  19. The cost of providing combined prevention and treatment services, including ART, to female sex workers in Burkina Faso.

    Directory of Open Access Journals (Sweden)

    Fiona Cianci

    Full Text Available BACKGROUND: Female Sex workers (FSW are important in driving HIV transmission in West Africa. The Yerelon clinic in Burkina Faso has provided combined preventative and therapeutic services, including anti-retroviral therapy (ART, for FSWs since 1998, with evidence suggesting it has decreased HIV prevalence and incidence in this group. No data exists on the costs of such a combined prevention and treatment intervention for FSW. This study aims to determine the mean cost of service provision per patient year for FSWs attending the Yerelon clinic, and identifies differences in costs between patient groups. METHODS: Field-based retrospective cost analyses were undertaken using top-down and bottom-up costing approaches for 2010. Expenditure and service utilisation data was collated from primary sources. Patients were divided into groups according to full-time or occasional sex-work, HIV status and ART duration. Patient specific service use data was extracted. Costs were converted to 2012 US$. Sensitivity analyses considered removal of all research costs, different discount rates and use of different ART treatment regimens and follow-up schedules. RESULTS: Using the top-down costing approach, the mean annual cost of service provision for FSWs on or off ART was US$1098 and US$882, respectively. The cost for FSWs on ART reduced by 29%, to US$781, if all research-related costs were removed and national ART monitoring guidelines were followed. The bottom-up patient-level costing showed the cost of the service varied greatly across patient groups (US$505-US$1117, primarily due to large differences in the costs of different ART regimens. HIV-negative women had the lowest annual cost at US$505. CONCLUSION: Whilst FSWs may require specialised services to optimise their care and hence, the public health benefits, our study shows that the cost of ART provision within a combined prevention and treatment intervention setting is comparable to providing ART to

  20. Impacts of intermittent renewable generation on electricity system costs

    International Nuclear Information System (INIS)

    Batalla-Bejerano, Joan; Trujillo-Baute, Elisa

    2016-01-01

    A successful deployment of power generation coming from variable renewable sources, such as wind and solar photovoltaic, strongly depends on the economic cost of system integration. This paper, in seeking to look beyond the impact of renewable generation on the evolution of the total economic costs associated with the operation of the electricity system, aims to estimate the sensitivity of balancing market requirements and costs to the variable and non-fully predictable nature of intermittent renewable generation. The estimations reported in this paper for the Spanish electricity system stress the importance of both attributes as well as power system flexibility when accounting for the cost of balancing services. - Highlights: •A successful deployment of VRES-E strongly depends on the economic cost of its integration. •We estimate the sensitivity of balancing market requirements and costs to VRES-E. •Integration costs depend on variability, predictability and system flexibility.

  1. Cost and performance analysis of physical security systems

    International Nuclear Information System (INIS)

    Hicks, M.J.; Yates, D.; Jago, W.H.; Phillips, A.W.

    1998-04-01

    Analysis of cost and performance of physical security systems can be a complex, multi-dimensional problem. There are a number of point tools that address various aspects of cost and performance analysis. Increased interest in cost tradeoffs of physical security alternatives has motivated development of an architecture called Cost and Performance Analysis (CPA), which takes a top-down approach to aligning cost and performance metrics. CPA incorporates results generated by existing physical security system performance analysis tools, and utilizes an existing cost analysis tool. The objective of this architecture is to offer comprehensive visualization of complex data to security analysts and decision-makers

  2. Integrated constructed wetland systems: design, operation, and performance of low-cost decentralized wastewater treatment systems.

    Science.gov (United States)

    Behrends, L L; Bailey, E; Jansen, P; Houke, L; Smith, S

    2007-01-01

    Several different types of constructed wetland systems are being used as decentralized treatment systems including surface-flow, subsurface-flow, vertical-flow, and hybrid systems. Archetypical wetland systems have design strengths and weaknesses, and therefore it should be possible to design combined (integrated) systems to optimize a number of important treatment processes. This study provides comparative efficacy data for two integrated wetland treatment systems (IWTS) designed to enhance treatment of medium strength wastewater generated from a pilot-scale intensive fish farm. Results from the twenty eight months study included consistently high removal of COD (84% +) and ammonia nitrogen (93%) in both systems. Initially, phosphorus removal was also high (>90%) in both systems, but removal efficacy declined significantly over time. Nitrate removal was significantly better in the system that provided sequential aerobic and anoxic environments. Short hydraulic retention times coupled with sustained removal of COD and ammonia indicate that the ReCip components could be a least-cost wastewater treatment technology in the decentralized market sector.

  3. Software Cost-Estimation Model

    Science.gov (United States)

    Tausworthe, R. C.

    1985-01-01

    Software Cost Estimation Model SOFTCOST provides automated resource and schedule model for software development. Combines several cost models found in open literature into one comprehensive set of algorithms. Compensates for nearly fifty implementation factors relative to size of task, inherited baseline, organizational and system environment and difficulty of task.

  4. Development of a Cost Effective Power Generation System: An Overview

    Directory of Open Access Journals (Sweden)

    Shiv Prakash Bihari

    2016-03-01

    Full Text Available This paper presents an overview on development of cost effective power generation system and motivates for development of a model for hybrid system with wind to investigate the combined operation of wind with different sources to cater to wind’s stochastic nature for imbalance minimization and optimal operation. Development of model for trading power in competitive electricity market and development of strategies for trading in electricity markets (wind energy and reserves markets to investigate the effects of real time pricing tariffs on electricity market operation has been illustrated in this paper. Dynamic modelling related studies to investigate the wind generator’s kinetic energy for primary frequency support using simulink and simulation studies on doubly fed induction generator to study its capability during small disturbances / fluctuations on power system have been described.

  5. Cost and Performance Model for Photovoltaic Systems

    Science.gov (United States)

    Borden, C. S.; Smith, J. H.; Davisson, M. C.; Reiter, L. J.

    1986-01-01

    Lifetime cost and performance (LCP) model assists in assessment of design options for photovoltaic systems. LCP is simulation of performance, cost, and revenue streams associated with photovoltaic power systems connected to electric-utility grid. LCP provides user with substantial flexibility in specifying technical and economic environment of application.

  6. Reliability and Cost Impacts for Attritable Systems

    Science.gov (United States)

    2017-03-23

    on reliability and cost: a probabilistic model. Electric Power Systems Research, 72(3), 213-224. Kalbfleisch, J.D. & Prentice, R.L. (1980). The...copyright protection in the United States. AFIT-ENV-MS-17-M-172 RELIABILITY AND COST IMPACTS FOR ATTRITABLE SYSTEMS THESIS Presented to... power of discrete time Markov chains, whether homogeneous or non-homogeneous, to model the reliability and dependability of repairable systems should

  7. A Low-Cost Environmental Monitoring System: How to Prevent Systematic Errors in the Design Phase through the Combined Use of Additive Manufacturing and Thermographic Techniques

    Directory of Open Access Journals (Sweden)

    Francesco Salamone

    2017-04-01

    Full Text Available nEMoS (nano Environmental Monitoring System is a 3D-printed device built following the Do-It-Yourself (DIY approach. It can be connected to the web and it can be used to assess indoor environmental quality (IEQ. It is built using some low-cost sensors connected to an Arduino microcontroller board. The device is assembled in a small-sized case and both thermohygrometric sensors used to measure the air temperature and relative humidity, and the globe thermometer used to measure the radiant temperature, can be subject to thermal effects due to overheating of some nearby components. A thermographic analysis was made to rule out this possibility. The paper shows how the pervasive technique of additive manufacturing can be combined with the more traditional thermographic techniques to redesign the case and to verify the accuracy of the optimized system in order to prevent instrumental systematic errors in terms of the difference between experimental and actual values of the above-mentioned environmental parameters.

  8. A Low-Cost Environmental Monitoring System: How to Prevent Systematic Errors in the Design Phase through the Combined Use of Additive Manufacturing and Thermographic Techniques.

    Science.gov (United States)

    Salamone, Francesco; Danza, Ludovico; Meroni, Italo; Pollastro, Maria Cristina

    2017-04-11

    nEMoS (nano Environmental Monitoring System) is a 3D-printed device built following the Do-It-Yourself (DIY) approach. It can be connected to the web and it can be used to assess indoor environmental quality (IEQ). It is built using some low-cost sensors connected to an Arduino microcontroller board. The device is assembled in a small-sized case and both thermohygrometric sensors used to measure the air temperature and relative humidity, and the globe thermometer used to measure the radiant temperature, can be subject to thermal effects due to overheating of some nearby components. A thermographic analysis was made to rule out this possibility. The paper shows how the pervasive technique of additive manufacturing can be combined with the more traditional thermographic techniques to redesign the case and to verify the accuracy of the optimized system in order to prevent instrumental systematic errors in terms of the difference between experimental and actual values of the above-mentioned environmental parameters.

  9. Costing systems design for sustainability

    Directory of Open Access Journals (Sweden)

    Mihaela TURTUREA

    2013-10-01

    Full Text Available The aim of this article is to present an overall image of the way Accounting responds to nowadays user’s needs in relation to the quantification of the impact companies have towards the environment. Regarding this, there have been analyzed concepts like sustainable development, environmental accounting, environmental costs and there have been presented the main progress towards environmental cost identification and measurement from the perspective of Activity Based Costing system. To provide an overall image of this concepts, there have been used as research methodology methods the documentation from literature review, analysis, synthesis and comparison.

  10. Cost Engineering Techniques and Their Applicability for Cost Estimation of Organic Rankine Cycle Systems

    Directory of Open Access Journals (Sweden)

    Sanne Lemmens

    2016-06-01

    Full Text Available The potential of organic Rankine cycle (ORC systems is acknowledged by both considerable research and development efforts and an increasing number of applications. Most research aims at improving ORC systems through technical performance optimization of various cycle architectures and working fluids. The assessment and optimization of technical feasibility is at the core of ORC development. Nonetheless, economic feasibility is often decisive when it comes down to considering practical instalments, and therefore an increasing number of publications include an estimate of the costs of the designed ORC system. Various methods are used to estimate ORC costs but the resulting values are rarely discussed with respect to accuracy and validity. The aim of this paper is to provide insight into the methods used to estimate these costs and open the discussion about the interpretation of these results. A review of cost engineering practices shows there has been a long tradition of industrial cost estimation. Several techniques have been developed, but the expected accuracy range of the best techniques used in research varies between 10% and 30%. The quality of the estimates could be improved by establishing up-to-date correlations for the ORC industry in particular. Secondly, the rapidly growing ORC cost literature is briefly reviewed. A graph summarizing the estimated ORC investment costs displays a pattern of decreasing costs for increasing power output. Knowledge on the actual costs of real ORC modules and projects remains scarce. Finally, the investment costs of a known heat recovery ORC system are discussed and the methodologies and accuracies of several approaches are demonstrated using this case as benchmark. The best results are obtained with factorial estimation techniques such as the module costing technique, but the accuracies may diverge by up to +30%. Development of correlations and multiplication factors for ORC technology in particular is

  11. Cost-effectiveness analysis of TOC removal from slaughterhouse wastewater using combined anaerobic-aerobic and UV/H2O2 processes.

    Science.gov (United States)

    Bustillo-Lecompte, Ciro Fernando; Mehrvar, Mehrab; Quiñones-Bolaños, Edgar

    2014-02-15

    The objective of this study is to evaluate the operating costs of treating slaughterhouse wastewater (SWW) using combined biological and advanced oxidation processes (AOPs). This study compares the performance and the treatment capability of an anaerobic baffled reactor (ABR), an aerated completely mixed activated sludge reactor (AS), and a UV/H2O2 process, as well as their combination for the removal of the total organic carbon (TOC). Overall efficiencies are found to be up to 75.22, 89.47, 94.53, 96.10, 96.36, and 99.98% for the UV/H2O2, ABR, AS, combined AS-ABR, combined ABR-AS, and combined ABR-AS-UV/H2O2 processes, respectively. Due to the consumption of electrical energy and reagents, operating costs are calculated at optimal conditions of each process. A cost-effectiveness analysis (CEA) is performed at optimal conditions for the SWW treatment by optimizing the total electricity cost, H2O2 consumption, and hydraulic retention time (HRT). The combined ABR-AS-UV/H2O2 processes have an optimal TOC removal of 92.46% at an HRT of 41 h, a cost of $1.25/kg of TOC removed, and $11.60/m(3) of treated SWW. This process reaches a maximum TOC removal of 99% in 76.5 h with an estimated cost of $2.19/kg TOC removal and $21.65/m(3) treated SWW, equivalent to $6.79/m(3) day. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Comparative study of the more promising combinations of blanket materials, power conversion systems, and tritium recovery and containment systems for fusion reactors

    International Nuclear Information System (INIS)

    Fraas, A.P.

    1975-11-01

    The many possible combinations of blanket materials, tritium generation and recovery systems, and power conversion systems were surveyed first by reviewing the principal design studies that have been prepared and then by examining a comprehensive set of designs generated by using a common set of ground rules that included all of the boundary conditions that could be envisioned. The results indicate that, of the wide variety of systems that have been considered, by far the most promising employs lithium recirculated in a closed loop within a niobium blanket structure and cooled with boiling potassium or cesium. This approach gives the simplest and lowest cost tritium recovery system, the lowest pressure and thermal stresses, the simplest structure with the lowest probability of a leak, the greatest resistance to damage from a plasma energy dump, and the lowest rate of plasma contamination by either outgassing or sputtering. The only other blanket materials combination that appears fairly likely to give a satisfactory tritium generation and recovery system is an Li 2 BeF 4 -Incoloy blanket, and even this system involves major uncertainties in the effectiveness, size, and cost of the tritium recovery system. Further, the Li 2 BeF 4 blanket system has the disadvantage that the world reserves of beryllium are too limited to support a full-blown fusion reactor economy, its poor thermal conductivity leads to cooling difficulties and a requirement for a complex structure with intricate cooling passages, and this inherently leads to an expensive blanket with a relatively high probability of leaks. The other blanket materials combinations yield even less attractive systems

  13. Marginal costs of water savings from cooling system retrofits: a case study for Texas power plants

    Science.gov (United States)

    Loew, Aviva; Jaramillo, Paulina; Zhai, Haibo

    2016-10-01

    The water demands of power plant cooling systems may strain water supply and make power generation vulnerable to water scarcity. Cooling systems range in their rates of water use, capital investment, and annual costs. Using Texas as a case study, we examined the cost of retrofitting existing coal and natural gas combined-cycle (NGCC) power plants with alternative cooling systems, either wet recirculating towers or air-cooled condensers for dry cooling. We applied a power plant assessment tool to model existing power plants in terms of their key plant attributes and site-specific meteorological conditions and then estimated operation characteristics of retrofitted plants and retrofit costs. We determined the anticipated annual reductions in water withdrawals and the cost-per-gallon of water saved by retrofits in both deterministic and probabilistic forms. The results demonstrate that replacing once-through cooling at coal-fired power plants with wet recirculating towers has the lowest cost per reduced water withdrawals, on average. The average marginal cost of water withdrawal savings for dry-cooling retrofits at coal-fired plants is approximately 0.68 cents per gallon, while the marginal recirculating retrofit cost is 0.008 cents per gallon. For NGCC plants, the average marginal costs of water withdrawal savings for dry-cooling and recirculating towers are 1.78 and 0.037 cents per gallon, respectively.

  14. Cost-effectiveness of combined oral bisphosphonate therapy and falls prevention exercise for fracture prevention in the USA.

    Science.gov (United States)

    Mori, T; Crandall, C J; Ganz, D A

    2017-02-01

    We developed a Markov microsimulation model among hypothetical cohorts of community-dwelling US white women without prior major osteoporotic fractures over a lifetime horizon. At ages 75 and 80, adding 1 year of exercise to 5 years of oral bisphosphonate therapy is cost-effective at a conventionally accepted threshold compared with bisphosphonates alone. The purpose of this study was to examine the cost-effectiveness of the combined strategy of oral bisphosphonate therapy for 5 years and falls prevention exercise for 1 year compared with either strategy in isolation. We calculated incremental cost-effectiveness ratios [ICERs] (2014 US dollars per quality-adjusted life year [QALY]), using a Markov microsimulation model among hypothetical cohorts of community-dwelling US white women with different starting ages (65, 70, 75, and 80) without prior history of hip, vertebral, or wrist fractures over a lifetime horizon from the societal perspective. At ages 65, 70, 75, and 80, the combined strategy had ICERs of $202,020, $118,460, $46,870, and $17,640 per QALY, respectively, compared with oral bisphosphonate therapy alone. The combined strategy provided better health at lower cost than falls prevention exercise alone at ages 70, 75, and 80. In deterministic sensitivity analyses, results were particularly sensitive to the change in the opportunity cost of participants' time spent exercising. In probabilistic sensitivity analyses, the probabilities of the combined strategy being cost-effective compared with the next best alternative increased with age, ranging from 35 % at age 65 to 48 % at age 80 at a willingness-to-pay of $100,000 per QALY. Among community-dwelling US white women ages 75 and 80, adding 1 year of exercise to 5 years of oral bisphosphonate therapy is cost-effective at a willingness-to-pay of $100,000 per QALY, compared with oral bisphosphonate therapy only. This analysis will help clinicians and policymakers make better decisions about treatment

  15. Online optimal control of variable refrigerant flow and variable air volume combined air conditioning system for energy saving

    International Nuclear Information System (INIS)

    Zhu, Yonghua; Jin, Xinqiao; Du, Zhimin; Fang, Xing

    2015-01-01

    The variable refrigerant flow (VRF) and variable air volume (VAV) combined air conditioning system can solve the problem of the VRF system in outdoor air ventilation while taking advantage of its high part load energy efficiency. Energy performance of the combined air conditioning system can also be optimized by joint control of both the VRF and the VAV parts. A model-based online optimal control strategy for the combined air conditioning system is presented. Simplified adaptive models of major components of the combined air conditioning system are firstly developed for predicting system performances. And a cost function in terms of energy consumption and thermal comfort is constructed. Genetic algorithm is used to search for the optimal control sets. The optimal control strategy is tested and evaluated through two case studies based on the simulation platform. Results show that the optimal strategy can effectively reduce energy consumption of the combined air conditioning system while maintaining acceptable thermal comfort. - Highlights: • A VRF and VAV combined system is proposed. • A model-based online optimal control strategy is proposed for the combined system. • The strategy can reduce energy consumption without sacrificing thermal comfort. • Novel simplified adaptive models are firstly developed for the VRF system

  16. 33 CFR 86.13 - Combined whistle systems.

    Science.gov (United States)

    2010-07-01

    ... systems. (a) A combined whistle system is a number of whistles (sound emitting sources) operated together... evidenced by at least two-thirds of the whistles in the combined system having fundamental frequencies... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Combined whistle systems. 86.13...

  17. Determination of cost effective waste management system receipt rates

    International Nuclear Information System (INIS)

    McKee, R.W.; Huber, H.D.

    1991-01-01

    A comprehensive logistics and cost analysis has been carried out to determine if there are potential benefits to the high-level waste management system for receipt rates other than the current 3000 MTU/yr design-basis. The analysis includes both a Repository-Only System and a Storage-Only System. Repository startup dates of 2010 and 2015 and MRS startup dates of 1988 and three years prior to the repository have been evaluated. Receipt rates ranging from 1,500 to 6, 000 MTU/yr have been considered. Higher receipt rates appear to be economically justified, for either system, minimum costs are found at a repository receipt rate of 6000 MTU/yr. However, the MRS receipt rate for minimum system costs depends on the MRS startup date. With a 1988 MRS and a 2010 repository, the added cost of providing the MRS is offset by at-reactor storage cost reductions and the total system cost of $10.0 billion is virtually the same as for the repository- only system. 9 refs., 8 figs., 3 tabs

  18. A low cost indoor localization system for mobile robot experimental setup

    Science.gov (United States)

    Adinandra, S.; Syarif, A.

    2018-04-01

    Indoor localization becomes one of the most important part in mobile robot system One fundamental requirement is to provide an easy-to-use and practical localization system for real-time experiments. In this paper we propose a combination of a recent open source virtual reality (VR) tools, a simple MATLAB code and a low cost USB webcam as an indoor mobile robot localization system Using the VR tools as a server and MATLAB as a client, the proposed solution can cover up to 1.6 [m] × 3.2 [m] with the measurement position accuracy up to 1.2 [cm]. The system is insensitive to light, easy to move and can be quickly set up. A series of successful real-time experiments with three different mobile robot types has been conducted.

  19. Economics of human performance and systems total ownership cost.

    Science.gov (United States)

    Onkham, Wilawan; Karwowski, Waldemar; Ahram, Tareq Z

    2012-01-01

    Financial costs of investing in people is associated with training, acquisition, recruiting, and resolving human errors have a significant impact on increased total ownership costs. These costs can also affect the exaggerate budgets and delayed schedules. The study of human performance economical assessment in the system acquisition process enhances the visibility of hidden cost drivers which support program management informed decisions. This paper presents the literature review of human total ownership cost (HTOC) and cost impacts on overall system performance. Economic value assessment models such as cost benefit analysis, risk-cost tradeoff analysis, expected value of utility function analysis (EV), growth readiness matrix, multi-attribute utility technique, and multi-regressions model were introduced to reflect the HTOC and human performance-technology tradeoffs in terms of the dollar value. The human total ownership regression model introduces to address the influencing human performance cost component measurement. Results from this study will increase understanding of relevant cost drivers in the system acquisition process over the long term.

  20. The next generation of urban MACCs. Reassessing the cost-effectiveness of urban mitigation options by integrating a systemic approach and social costs

    International Nuclear Information System (INIS)

    Saujot, Mathieu; Lefèvre, Benoit

    2016-01-01

    Many cities are implementing policies and climate action plans. Yet local climate policies suffer from a lack of scientific understanding and evaluation methods able to support the definition of efficient mitigation strategies. The purpose of this paper is to build on classical approaches in the energy policy field that exist at the national and international level to propose an urban MACCs methodology able to fulfill this lack and inform local debates. The methodology is an extension of static “expert-based” MACCs; it combines a land use transport integrated model and an abatement cost methodology that integrates co-benefits, and takes into account the spatial and systemic dimensions of cities. The methodology is implemented for the transportation sector of a mid-sized European city (Grenoble, France). Our results present the cost-effectiveness and political feasibility of several proposed measures. We find that the inclusion of co-benefits can profoundly change the cost-benefit assessment of transport mitigation options. Moreover we underline the key parameters determining the cost-effectiveness ranking of mitigation options. These urban MACCs aim to serve as a bridge between urban planning and mitigation policies and can thus contribute to strengthen and align sustainable and climate change agendas at the local level. - Highlights: •Local climate policies lack scientific understanding for prioritizing mitigation actions. •We develop a method to evaluate cost-effectiveness of urban transportation actions. •This method combines urban modeling and MACCs to inform urban planning. •Abatement costs from its application to a mid-sized city are presented. •The impact of the inclusion of co-benefits is analyzed.

  1. Combined Regional Investments Could Substantially Enhance Health System Performance And Be Financially Affordable.

    Science.gov (United States)

    Homer, Jack; Milstein, Bobby; Hirsch, Gary B; Fisher, Elliott S

    2016-08-01

    Leaders across the United States face a difficult challenge choosing among possible approaches to transform health system performance in their regions. The ReThink Health Dynamics Model simulates how alternative scenarios could unfold through 2040. This article compares the likely consequences if four interventions were enacted in layered combinations in a prototypical midsize US city. We estimated the effects of efforts to deliver higher-value care; reinvest savings and expand global payment; enable healthier behaviors; and expand socioeconomic opportunities. Results suggest that there may be an effective and affordable way to unlock much greater health and economic potential, ultimately reducing severe illness by 20 percent, lowering health care costs by 14 percent, and improving economic productivity by 9 percent. This would require combined investments in clinical and population-level initiatives, coupled with financial agreements that reduce incentives for costly care and reinvest a share of the savings to ensure adequate long-term financing. Project HOPE—The People-to-People Health Foundation, Inc.

  2. Cost-effectiveness of single-dose tamsulosin and dutasteride combination therapy compared with tamsulosin monotherapy in patients with benign prostatic hyperplasia in the UK.

    Science.gov (United States)

    Walker, Anna; Doyle, Scott; Posnett, John; Hunjan, Manjit

    2013-09-01

    To estimate the long-term cost-effectiveness of single-dose dutasteride/tamsulosin combination therapy as a first-line treatment for benign prostatic hyperplasia (BPH) from the perspective of the UK National Health Service (NHS). A Markov state transition model was developed to estimate healthcare costs and patient outcomes, measured by quality-adjusted life years (QALYs), for patients aged ≥50 years with diagnosed BPH and moderate to severe symptoms. Costs and outcomes were estimated for two treatment comparators: oral, daily, single-dose combination therapy (dutasteride 0.5 mg + tamsulosin 0.4 mg), and oral daily tamsulosin (0.4 mg) over a period up to 25 years. The efficacy of comparators was taken from results of the Combination of Avodart and Tamsulosin (CombAT) trial. Cumulative discounted costs per patient were higher with combination therapy than with tamsulosin, but QALYs were also higher. After 25 years, the incremental cost-effectiveness ratio for combination therapy was £12,219, well within the threshold range (£20,000-£30,000 per QALY) typically applied in the NHS. Probabilistic sensitivity analysis showed that the probability of combination therapy being cost-effective given the threshold range is between 78% and 88%. Single-dose combination dutasteride/tamsulosin therapy has a high probability of being cost-effective in comparison to tamsulosin monotherapy in the UK's NHS. © 2013 BJU International.

  3. Numerical Analysis of Combined Well and Open-Closed Loops Geothermal (CWG) Systems

    Science.gov (United States)

    Park, Yu-Chul

    2016-04-01

    Open-loop geothermal heat pump (GHP) system and closed-loop heat pump systems have been used in Korea to reduce emission of greenhouse gases such as carbon dioxide (CO2). The GHP systems have the pros and cons, for example, the open-loop GHP system is good energy-efficient and the closed-loop GHP system requires minimum maintenance costs. The open-loop GHP system can be used practically only with large amount of groundwater supply. The closed-loop GHP system can be used with high costs of initial installation. The performance and efficiency of the GHP system depend on the characteristics of the GHP system itself in addition to the geologic conditions. To overcome the cons of open-loop or closed-loop GHP system, the combined well and open-closed loops geothermal (CWG) system was designed. The open-loop GHP system is surrounded with closed-loop GHP systems in the CWG system. The geothermal energy in closed-loop GHP systems is supplied by the groundwater pumped by the open-loop GHP system. In this study, 2 different types of the CWG systems (small aperture hybrid CWG system and large aperture CWG system) are estimated using numerical simulation models in the aspect of energy efficiency. This work was supported by the New & Renewable Energy Core Technology Program of the Korea Institute of Energy Technology Evaluation and Planning (KETEP), granted financial resource from the Ministry of Trade, Industry & Energy, Republic of Korea. (No.20153030111120).

  4. Cost and effectiveness of radon barrier systems

    International Nuclear Information System (INIS)

    Baker, E.G.; Freeman, H.D.; Hartley, J.N.; Gee, G.W.

    1982-12-01

    Earthen, asphalt, and multilayer radon barrier systems can all provide reduction in the amount of radon gas released from uranium mill tailings. Pacific Northwest Laboratory field tested all three types of covers at Grand Junction, Colorado during the summer of 1981. All nine individual radon barrier systems tested currently meet the EPA standard for radon flux of 20 pCi m - 2 s - 1 . The cost of the asphalt and 3m earthen covers were about the same at the field test. Multilayer covers were significantly more costly. Cost estimates for three high priority western sites indicate 3m of earthen cover is the least costly radon barrier when earthen material is available at or near the disposal site. If earthen material must be imported more than 8 to 10 km asphalt and possibly multilayer radon barriers can be cost effective

  5. Cost-effectiveness analysis of different types of human papillomavirus vaccination combined with a cervical cancer screening program in mainland China.

    Science.gov (United States)

    Mo, Xiuting; Gai Tobe, Ruoyan; Wang, Lijie; Liu, Xianchen; Wu, Bin; Luo, Huiwen; Nagata, Chie; Mori, Rintaro; Nakayama, Takeo

    2017-07-18

    China has a high prevalence of human papillomavirus (HPV) and a consequently high burden of disease with respect to cervical cancer. The HPV vaccine has proved to be effective in preventing cervical cancer and is now a part of routine immunization programs worldwide. It has also proved to be cost effective. This study aimed to assess the cost-effectiveness of 2-, 4-, and 9-valent HPV vaccines (hereafter, HPV2, 4 or 9) combined with current screening strategies in China. A Markov model was developed for a cohort of 100,000 HPV-free girls to simulate the natural history to HPV infection. Three recommended screening methods (1. liquid-based cytology test + HPV DNA test; 2. pap smear cytology test + HPV DNA test; 3. visual inspection with acetic acid) and three types of HPV vaccination program (HPV2/4/9) were incorporated into 15 intervention options, and the incremental cost-effectiveness ratio (ICER) was calculated to determine the dominant strategies. Costs, transition probabilities and utilities were obtained from a review of the literature and national databases. One-way sensitivity analyses and threshold analyses were performed for key variables in different vaccination scenarios. HPV9 combined with screening showed the highest health impact in terms of reducing HPV-related diseases and increasing the number of quality-adjusted life years (QALYs). Under the current thresholds of willingness to pay (WTP, 3 times the per capita GDP or USD$ 23,880), HPV4/9 proved highly cost effective, while HPV2 combined with screening cost more and was less cost effective. Only when screening coverage increased to 60% ~ 70% did the HPV2 and screening combination strategy become economically feasible. The combination of the HPV4/9 vaccine with current screening strategies for adolescent girls was highly cost-effective and had a significant impact on reducing the HPV infection-related disease burden in Mainland China.

  6. Systemic combination treatment for psoriasis: a review

    DEFF Research Database (Denmark)

    Jensen, Peter; Skov, Lone; Zachariae, Claus

    2010-01-01

    exist for the use of systemic combination therapy. Therefore, our aim was to review the current literature on systemic anti-psoriatic combination regimens. We searched PubMed and identified 98 papers describing 116 studies (23 randomized) reporting on the effect of various systemic combination...

  7. U.S. Solar Photovoltaic System Cost Benchmark: Q1 2016

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Ran [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chung, Donald [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lowder, Travis [National Renewable Energy Lab. (NREL), Golden, CO (United States); Feldman, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ardani, Kristen [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    NREL has been modeling U.S. photovoltaic (PV) system costs since 2009. This report benchmarks costs of U.S. solar PV for residential, commercial, and utility-scale systems built in the first quarter of 2016 (Q1 2016). Our methodology includes bottom-up accounting for all system and project-development costs incurred when installing residential, commercial, and utility-scale systems, and it models the capital costs for such systems.

  8. U.S. Solar Photovoltaic System Cost Benchmark: Q1 2016

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Ran; Chung, Donald; Lowder, Travis; Feldman, David; Ardani, Kristen; Margolis, Robert

    2016-07-19

    NREL has been modeling U.S. photovoltaic (PV) system costs since 2009. This report benchmarks costs of U.S. solar PV for residential, commercial, and utility-scale systems built in the first quarter of 2016 (Q1 2016). Our methodology includes bottom-up accounting for all system and project-development costs incurred when installing residential, commercial, and utility-scale systems, and it models the capital costs for such systems.

  9. Two-stage absorber systems - Economically viable combined heat and cold generation; Wirtschaftlicher Kraft-Waerme-Kaelte-Verbund

    Energy Technology Data Exchange (ETDEWEB)

    Biniossek, H. [Giesecke und Devrient, Muenchen (Germany); Schmid, W. [Technische Gebaeudeausruestung, Muenchen (Germany)

    2008-07-01

    This article takes a look at how the possibilities of optimising power, heat and cold generation for the German Giesecke and Devrient company were examined and implemented. The company, which produces banknotes and chip-cards, chose the combination of a Combined Heat and Power (CHP) Unit and a two-stage absorber refrigeration system. The company's old system is briefly described and the reasons for replacing it are discussed. The careful dimensioning of the new system and the search for appropriate equipment are described. Intelligent power flows and a cooling system with two different temperature levels are described. Costs saved and emergency power generation are also looked at, as are the complex demands placed on the control of the system. The system's functioning is briefly described.

  10. Determination of cost effective waste management system receipt rates

    International Nuclear Information System (INIS)

    McKee, R.W.; Huber, H.D.

    1991-01-01

    A comprehensive logistics and cost analysis has been carried out to determine if there are potential benefits to the high-level waste management system for receipt rates other than the current 3,000 MTU/yr design-basis receipt rate. The scope of the analysis includes both a Repository-Only System and a Storage-Only or Basic MRS System. To allow for current uncertainties in facility startup scheduling, cases considering repository startup dates of 2010 and 2015 and MRS startup dates of 1998 and three years prior to the repository have been evaluated. Receipt rates ranging from 1,500 to 6,000 MTU/yr have been considered for both the MRS and the repository. Higher receipt rates appear to be economically justified for both the repository and an MRS. For a repository-only system, minimum costs are found at a repository receipt rate of 6,000 MTU/yr. When a storage-only MRS is included in the system, minimum system costs are also achieved at a repository receipt rate of 6,000 MTU/yr. However, the MRS receipt rate for minimum system costs depends on the MRS startup date and ranges from 3,500 to 6,000 MTU/yr. With a 1998 MRS and a 2010 repository, the added cost of providing the MRS is offset by at-reactor storage cost reductions and the total system cost of $10.0 billion is virtually the same as for the repository-only system

  11. Linear collider systems and costs

    International Nuclear Information System (INIS)

    Loew, G.A.

    1993-05-01

    The purpose of this paper is to examine some of the systems and sub-systems involved in so-called ''conventional'' e + e - linear colliders and to study how their design affects the overall cost of these machines. There are presently a total of at least six 500 GeV c. of m. linear collider projects under study in the world. Aside from TESLA (superconducting linac at 1.3 GHz) and CLIC (two-beam accelerator with main linac at 30GHz), the other four proposed e + e - linear colliders can be considered ''conventional'' in that their main linacs use the proven technique of driving room temperature accelerator sections with pulsed klystrons and modulators. The centrally distinguishing feature between these projects is their main linac rf frequency: 3 GHz for the DESY machine, 11.424 GHz for the SLAC and JLC machines, and 14 GHz for the VLEPP machine. The other systems, namely the electron and positron sources, preaccelerators, compressors, damping rings and final foci, are fairly similar from project to project. Probably more than 80% of the cost of these linear colliders will be incurred in the two main linacs facing each other and it is therefore in their design and construction that major savings or extra costs may be found

  12. ASSESSMENT OF COMBINED HEAT AND POWER SYSTEM"PREMIUM POWER" APPLICATIONS IN CALIFORNIA

    Energy Technology Data Exchange (ETDEWEB)

    Norwood, Zack; Lipman, Timothy; Stadler, Michael; Marnay, Chris

    2010-06-01

    The effectiveness of combined heat and power (CHP) systems for power interruption intolerant,"premium power," facilities is the focus of this study. Through three real-world case studies and economic cost minimization modeling, the economic and environmental performance of"premium power" CHP is analyzed. The results of the analysis for a brewery, data center, and hospital lead to some interesting conclusions about CHP limited to the specific CHP technologies installed at those sites. Firstly, facilities with high heating loads prove to be the most appropriate for CHP installations from a purely economic standpoint. Secondly, waste heat driven thermal cooling systems are only economically attractive if the technology for these chillers can increase above the current best system efficiency. Thirdly, if the reliability of CHP systems proves to be as high as diesel generators they could replace these generators at little or no additional cost if the thermal to electric (relative) load of those facilities was already high enough to economically justify a CHP system. Lastly, in terms of greenhouse gas emissions, the modeled CHP systems provide some degree of decreased emissions, estimated at approximately 10percent for the hospital, the application with the highest relative thermal load in this case

  13. Systemic combination treatment for psoriasis: a review

    DEFF Research Database (Denmark)

    Jensen, Peter; Skov, Lone; Zachariae, Claus

    2010-01-01

    Psoriasis is a chronic inflammatory skin disease, which affects approximately 2.6% of the population in Northern Europe and Scandinavia. In order to achieve disease control, combinations of systemic treatments are sometimes needed for variable time periods. However, no evidence-based guidelines...... exist for the use of systemic combination therapy. Therefore, our aim was to review the current literature on systemic anti-psoriatic combination regimens. We searched PubMed and identified 98 papers describing 116 studies (23 randomized) reporting on the effect of various systemic combination...

  14. A Proposal for Automatic Fruit Harvesting by Combining a Low Cost Stereovision Camera and a Robotic Arm

    Science.gov (United States)

    Font, Davinia; Pallejà, Tomàs; Tresanchez, Marcel; Runcan, David; Moreno, Javier; Martínez, Dani; Teixidó, Mercè; Palacín, Jordi

    2014-01-01

    This paper proposes the development of an automatic fruit harvesting system by combining a low cost stereovision camera and a robotic arm placed in the gripper tool. The stereovision camera is used to estimate the size, distance and position of the fruits whereas the robotic arm is used to mechanically pickup the fruits. The low cost stereovision system has been tested in laboratory conditions with a reference small object, an apple and a pear at 10 different intermediate distances from the camera. The average distance error was from 4% to 5%, and the average diameter error was up to 30% in the case of a small object and in a range from 2% to 6% in the case of a pear and an apple. The stereovision system has been attached to the gripper tool in order to obtain relative distance, orientation and size of the fruit. The harvesting stage requires the initial fruit location, the computation of the inverse kinematics of the robotic arm in order to place the gripper tool in front of the fruit, and a final pickup approach by iteratively adjusting the vertical and horizontal position of the gripper tool in a closed visual loop. The complete system has been tested in controlled laboratory conditions with uniform illumination applied to the fruits. As a future work, this system will be tested and improved in conventional outdoor farming conditions. PMID:24984059

  15. A Proposal for Automatic Fruit Harvesting by Combining a Low Cost Stereovision Camera and a Robotic Arm

    Directory of Open Access Journals (Sweden)

    Davinia Font

    2014-06-01

    Full Text Available This paper proposes the development of an automatic fruit harvesting system by combining a low cost stereovision camera and a robotic arm placed in the gripper tool. The stereovision camera is used to estimate the size, distance and position of the fruits whereas the robotic arm is used to mechanically pickup the fruits. The low cost stereovision system has been tested in laboratory conditions with a reference small object, an apple and a pear at 10 different intermediate distances from the camera. The average distance error was from 4% to 5%, and the average diameter error was up to 30% in the case of a small object and in a range from 2% to 6% in the case of a pear and an apple. The stereovision system has been attached to the gripper tool in order to obtain relative distance, orientation and size of the fruit. The harvesting stage requires the initial fruit location, the computation of the inverse kinematics of the robotic arm in order to place the gripper tool in front of the fruit, and a final pickup approach by iteratively adjusting the vertical and horizontal position of the gripper tool in a closed visual loop. The complete system has been tested in controlled laboratory conditions with uniform illumination applied to the fruits. As a future work, this system will be tested and improved in conventional outdoor farming conditions.

  16. Historical Cost Growth of Completed Weapon System Programs

    National Research Council Canada - National Science Library

    Arena, Mark V; Leonard, Robert S; Murray, Sheila E; Younossi, Obaid

    2006-01-01

    ...: Cost Risk Analysis for Air Force Systems," and includes a literature review of cost growth studies and a more extensive analysis of the historical cost growth in acquisition programs than appears...

  17. Performance of U.S. hybrid distributed energy systems: Solar photovoltaic, battery and combined heat and power

    International Nuclear Information System (INIS)

    Shah, Kunal K.; Mundada, Aishwarya S.; Pearce, J.M.

    2015-01-01

    Highlights: • Simulated PV + battery + CHP hybrid systems deployed in three U.S. regions. • Used hybrid optimization model for electric renewable pro microgrid analysis. • Limited size of each sub-module to singe family house size. • Results show that the electricity generated meets residential load demand. • Hybrid systems are technically viable in hot, moderate and cold climates in U.S. - Abstract: Until recently, the relatively high levelized cost of electricity from solar photovoltaic (PV) technology limited deployment; however, recent cost reductions, combined with various financial incentives and innovative financing techniques, have made PV fully competitive with conventional sources in many American regions. In addition, the costs of electrical storage have also declined enough to make PV + battery systems potentially economically viable for a mass-scale off-grid low-emission transition. However, many regions in the U.S. (e.g. Northern areas) cannot have off-grid PV systems without prohibitively large battery systems. Small-scale combined heat and power (CHP) systems provide a potential solution for off-grid power backup of residential-scale PV + battery arrays, while also minimizing emissions from conventional sources. Thus, an opportunity is now available to maximize the use of solar energy and gain the improved efficiencies possible with CHPs to deploy PV + battery + CHP systems throughout the U.S. The aim of this study is to determine the technical viability of such systems by simulating PV + battery + CHP hybrid systems deployed in three representative regions in the U.S., using the Hybrid Optimization Model for Electric Renewable (HOMER) Pro Microgrid Analysis tool. The results show that the electricity generated by each component of the hybrid system can be coupled to fulfill the residential load demand. A sensitivity analysis of these hybrid off grid systems is carried out as a function capacity factor of both the PV and CHP units. The

  18. Final Report: Hydrogen Storage System Cost Analysis

    Energy Technology Data Exchange (ETDEWEB)

    James, Brian David [Strategic Analysis Inc., Arlington, VA (United States); Houchins, Cassidy [Strategic Analysis Inc., Arlington, VA (United States); Huya-Kouadio, Jennie Moton [Strategic Analysis Inc., Arlington, VA (United States); DeSantis, Daniel A. [Strategic Analysis Inc., Arlington, VA (United States)

    2016-09-30

    The Fuel Cell Technologies Office (FCTO) has identified hydrogen storage as a key enabling technology for advancing hydrogen and fuel cell power technologies in transportation, stationary, and portable applications. Consequently, FCTO has established targets to chart the progress of developing and demonstrating viable hydrogen storage technologies for transportation and stationary applications. This cost assessment project supports the overall FCTO goals by identifying the current technology system components, performance levels, and manufacturing/assembly techniques most likely to lead to the lowest system storage cost. Furthermore, the project forecasts the cost of these systems at a variety of annual manufacturing rates to allow comparison to the overall 2017 and “Ultimate” DOE cost targets. The cost breakdown of the system components and manufacturing steps can then be used to guide future research and development (R&D) decisions. The project was led by Strategic Analysis Inc. (SA) and aided by Rajesh Ahluwalia and Thanh Hua from Argonne National Laboratory (ANL) and Lin Simpson at the National Renewable Energy Laboratory (NREL). Since SA coordinated the project activities of all three organizations, this report includes a technical description of all project activity. This report represents a summary of contract activities and findings under SA’s five year contract to the US Department of Energy (Award No. DE-EE0005253) and constitutes the “Final Scientific Report” deliverable. Project publications and presentations are listed in the Appendix.

  19. Increased accuracy of cost-estimation using product configuration systems

    DEFF Research Database (Denmark)

    Rasmussen, Jeppe Bredahl; Hvam, Lars; Mortensen, Niels Henrik

    This article describes an approach for utilizing Product Configuration Systems (PCS) for quantifying project costs in project-based companies. It presents a case study demonstrating a method of quantifying costs in a way that makes it possible to configure cost- and time estimates. Piecework costs......, material costs and sub-supplier costs are used as principle cost elements and linked to structural and process elements to facilitate configuration. The cost data are used by the PCS to generate fast and accurate cost-estimates, quotations, time estimates and cost summaries. The described cost...... quantification principles have been used in a Scandinavian SME (Small and Medium-sized Enterprise) since the 90’s, but have since 2011 been adopted to be used in a configuration system. A longitudinal case study was conducted to compare cost and time-estimation accuracy before and after implementation. We...

  20. Mental health services costs within the Alberta criminal justice system.

    Science.gov (United States)

    Jacobs, Philip; Moffatt, Jessica; Dewa, Carolyn S; Nguyen, Thanh; Zhang, Ting; Lesage, Alain

    2016-01-01

    Mental illness has been widely cited as a driver of costs in the criminal justice system. The objective of this paper is to estimate the additional mental health service costs incurred within the criminal justice system that are incurred because of people with mental illnesses who go through the system. Our focus is on costs in Alberta. We set up a model of the flow of all persons through the criminal justice system, including police, court, and corrections components, and for mental health diversion, review, and forensic services. We estimate the transitional probabilities and costs that accrue as persons who have been charged move through the system. Costs are estimated for the Alberta criminal justice system as a whole, and for the mental illness component. Public expenditures for each person diverted or charged in Alberta in the criminal justice system, including mental health costs, were $16,138. The 95% range of this estimate was from $14,530 to $19,580. Of these costs, 87% were for criminal justice services and 13% were for mental illness-related services. Hospitalization for people with mental illness who were reviewed represented the greatest additional cost associated with mental illnesses. Treatment costs stemming from mental illnesses directly add about 13% onto those in the criminal justice system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Cost/benefit analyses of reactor safety systems

    International Nuclear Information System (INIS)

    1988-01-01

    The study presents a methodology for quantitative assessment of the benefit yielded by the various engineered safety systems of a nuclear reactor containment from the standpoint of their capacity to protect the environment compared to their construction costs. The benefit is derived from an estimate of the possible damage from which the environment is protected, taking account of the probabilities of occurrence of malfunctions and accidents. For demonstration purposes, the methodology was applied to a 1 300-MWe PWR nuclear power station. The accident sequence considered was that of a major loss-of-coolant accident as investigated in detail in the German risk study. After determination of the benefits and cost/benefit ratio for the power plant and the containment systems as designed, the performance characteristics of three subsystems, the leakoff system, annulus exhaust air handling system and spray system, were varied. For this purpose, the parameters which describe these systems in the activity release programme were altered. The costs were simultaneously altered in order to take account of the performance divergences. By varying the performance of the individual sub-systems an optimization in design of these systems can be arrived at

  2. Description and cost analysis of a deluge dry/wet cooling system.

    Energy Technology Data Exchange (ETDEWEB)

    Wiles, L.E.; Bamberger, J.A.; Braun, D.J.; Braun, D.J.; Faletti, D.W.; Willingham, C.E.

    1978-06-01

    The use of combined dry/wet cooling systems for large base-load power plants offers the potential for significant water savings as compared to evaporatively cooled power plants and significant cost savings in comparison to dry cooled power plants. The results of a detailed engineering and cost study of one type of dry/wet cooling system are described. In the ''deluge'' dry/wet cooling method, a finned-tube heat exchanger is designed to operate in the dry mode up to a given ambient temperature. To avoid the degradation of performance for higher ambient temperatures, water (the delugeate) is distributed over a portion of the heat exchanger surface to enhance the cooling process by evaporation. The deluge system used in this study is termed the HOETERV system. The HOETERV deluge system uses a horizontal-tube, vertical-plate-finned heat exchanger. The delugeate is distributed at the top of the heat exchanger and is allowed to fall by gravity in a thin film on the face of the plate fin. Ammonia is used as the indirect heat transfer medium between the turbine exhaust steam and the ambient air. Steam is condensed by boiling ammonia in a condenser/reboiler. The ammonia is condensed in the heat exchanger by inducing airflow over the plate fins. Various design parameters of the cooling system have been studied to evaluate their impact on the optimum cooling system design and the power-plant/utility-system interface. Annual water availability was the most significant design parameter. Others included site meteorology, heat exchanger configuration and air flow, number and size of towers, fan system design, and turbine operation. It was concluded from this study that the HOETERV deluge system of dry/wet cooling, using ammonia as an intermediate heat transfer medium, offers the potential for significant cost savings compared with all-dry cooling, while achieving substantially reduced water consumption as compared to an evaporatively cooled power plant. (LCL)

  3. Combining optimisation and simulation in an energy systems analysis of a Swedish iron foundry

    International Nuclear Information System (INIS)

    Mardan, Nawzad; Klahr, Roger

    2012-01-01

    To face global competition, and also reduce environmental and climate impact, industry-wide changes are needed, especially regarding energy use, which is closely related to global warming. Energy efficiency is therefore an essential task for the future as it has a significant impact on both business profits and the environment. For the analysis of possible changes in industrial production processes, and to choose what changes should be made, various modelling tools can be used as a decision support. This paper uses two types of energy analysis tool: Discrete Event Simulation (DES) and Energy Systems Optimisation (ESO). The aim of this study is to describe how a DES and an ESO tool can be combined. A comprehensive five-step approach is proposed for reducing system costs and making a more robust production system. A case study representing a new investment in part of a Swedish iron foundry is also included to illustrate the method's use. The method described in this paper is based on the use of the DES program QUEST and the ESO tool reMIND. The method combination itself is generic, i.e. other similar programs can be used as well with some adjustments and adaptations. The results from the case study show that when different boundary conditions are used the result obtained from the simulation tools is not optimum, in other words, the result shows only a feasible solution and not the best way to run the factory. It is therefore important to use the optimisation tool in such cases in order to obtain the optimum operating strategy. By using the optimisation tool a substantial amount of resources can be saved. The results also show that the combination of optimisation and simulation tools is useful to provide very detailed information about how the system works and to predict system behaviour as well as to minimise the system cost. -- Highlights: ► This study describes how a simulation and an optimisation tool can be combined. ► A case study representing a new

  4. Systematization of Cost Factors for Cost Management at Industrial Enterprises

    Directory of Open Access Journals (Sweden)

    N. Y.

    2017-12-01

    Full Text Available Identification and structuring of factors determining the cost level has significant importance in cost analysis and control. Cost factors need to be systematized for more effective cost management. The objective of the study is to identify and structure the factors with impact on the enterprise costs. The external and internal factors with impact on the enterprise costs in industry are highlighted. For cost management purposes, it is proposed to group the cost factors into the two categories: structural and functional. The essence of structural and functional factors is shown; a classification of functional factors is given. The effect of a structural factor such as products range (complexity is illustrated. As the factor of complexity, combined with cost analysis systems and innovative tools of analysis (ABC and XYZ methods, has been increasingly in focus of analysts, three problems are described which, once dealt with, will enable ABC method to fit into the cost management system. The importance of another structural factor of costs, technology selection, in cost management is shown. The analysis allows for the following conclusions: for purposes of current cost management, including one based on operational analysis, the output needs to be addressed as the central factor determining the cost level; in the strategic perspective, an enterprise needs to concentrate on calculating the costs for the structural alternatives that are supposed to determine its competitive position; for cost management purposes, the cost factors should be broken into two categories, structural and functional; a specific management system exists for each cost factor, which is greatly important for the positioning of an enterprise.

  5. Cost-effectiveness of combination therapy umeclidinium/vilanterol versus tiotropium in symptomatic COPD Spanish patients

    Directory of Open Access Journals (Sweden)

    Miravitlles M

    2016-01-01

    Full Text Available Marc Miravitlles,1 Juan B Gáldiz,2 Alicia Huerta,3 Alba Villacampa,4 David Carcedo,4 Francisco Garcia-Rio5 1Pneumology Department, Hospital Universitari Vall d’Hebron, CIBER de Enfermedades Respiratorias (CIBERES, Barcelona, 2Pneumology Department, Hospital Universitario de Cruces, CIBER de Enfermedades Respiratorias (CIBERES, Bilbao, 3GlaxoSmithKline, Madrid, 4Oblikue Consulting, Barcelona, 5Pneumology Department, Hospital Universitario La Paz, IdiPAZ, Madrid, Spain Purpose: Umeclidinium/vilanterol (UMEC/VI is a novel fixed dose combination of a long-acting muscarinic receptor antagonist (LAMA and a long-acting beta 2 receptor antagonist (LABA agent. This analysis evaluated the incremental cost-effectiveness ratio (ICER of UMEC/VI compared with tiotropium (TIO, from the Spanish National Health System (NHS perspective.Methods: A previously published linked equations cohort model based on the epidemiological longitudinal study ECLIPSE (Evaluation of COPD Longitudinally to Identify Predictive Surrogate End-points was used. Patients included were COPD patients with a post-bronchodilator forced expiratory volume in 1 second (FEV1 ≤70% and the presence of respiratory symptoms measured with the modified Medical Research Council dyspnea scale (modified Medical Research Council ≥2. Treatment effect, expressed as change in FEV1 from baseline, was estimated from a 24-week head-to-head phase III clinical trial comparing once-daily UMEC/VI with once-daily TIO and was assumed to last 52 weeks following treatment initiation (maximum duration of UMEC/VI clinical trials. Spanish utility values were derived from a published local observational study. Unitary health care costs (€2015 were obtained from local sources. A 3-year time horizon was selected, and 3% discount was applied to effects and costs. Results were expressed as cost/quality-adjusted life years (QALYs. Univariate and probabilistic sensitivity analysis (PSA was performed.Results: UMEC

  6. Changing World, Unchanging Accounting? Cost Systems for Hungarian Agricultural Companies

    OpenAIRE

    Zoltán Musinszki

    2011-01-01

    The literature of agricultural cost accounting has defined the definition of cost centres and cost bearers, the contents of the accounts, the procedures and methods for cost accounting and unit cost calculation without any significant changes for decades now. Do the agricultural companies set up and operate their own cost allocation and unit cost calculation systems on procedures made for state owned farms and cooperatives, or do they align their cost system with the challenges of our times? ...

  7. Cost of radon-barrier systems for uranium mill tailings

    International Nuclear Information System (INIS)

    Baker, E.G.; Hartley, J.N.

    1982-08-01

    This report deals specifically with the cost of three types of radon barrier systems, earthen covers, asphalt emulsion covers, and multilayer covers, which could meet standards proposed by the Environmental Protection Agency to stabilize uranium mill tailings located primarily in the western US. In addition, the report includes a sensitivity analysis of various factors which significantly effect the overall cost of the three systems. These analyses were based on a generic disposal site. Four different 3m thick earthen covers were tested and cost an average of $27/m 2 . The least expensive earthen cover cost was about $21/m 2 . The asphalt cover system (6 to 7 cm of asphalt topped with 0.6m of overburden) cost about $28/m 2 . The four multilayer covers averaged $57/m 2 , but materials handling problems encountered during the test inflated this cost above what was anticipated and significant cost reductions should be possible. The least expensive multilayer cover cost $43/m 2 . Based on the results of the Grand Junction field test we estimated the cost of covering the tailings from three high priority sites, Durango, Shiprock, and Salt Lake City (Vitro). The cost of a 3m earthen cover ranged from $18 to 33/m 2 for the seven disposal sites (two or three at each location) studied. The cost of asphalt cover systems were $23 to 28/m 2 and the multilayer cover costs were between $31 to 36/m 2 . The earthen cover costs are less than the Grand Junction field test cost primarily because cover material is available at or near most of the disposal sites selected. Earthen material was imported from 6 to 10 miles for the field test. Assuming more efficienct utilization of materials significantly reduced the cost of the multilayer covers

  8. Extreme Cost Reductions with Multi-Megawatt Centralized Inverter Systems

    Energy Technology Data Exchange (ETDEWEB)

    Schwabe, Ulrich [Alencon LLC; Fishman, Oleg [Alencon LLC

    2015-03-20

    The objective of this project was to fully develop, demonstrate, and commercialize a new type of utility scale PV system. Based on patented technology, this includes the development of a truly centralized inverter system with capacities up to 100MW, and a high voltage, distributed harvesting approach. This system promises to greatly impact both the energy yield from large scale PV systems by reducing losses and increasing yield from mismatched arrays, as well as reduce overall system costs through very cost effective conversion and BOS cost reductions enabled by higher voltage operation.

  9. Potential Cost Savings with 3D Printing Combined With 3D Imaging and CPLM for Fleet Maintenance and Revitalization

    Science.gov (United States)

    2014-05-01

    1 Potential Cost Savings with 3D Printing Combined With 3D Imaging and CPLM for Fleet Maintenance and Revitalization David N. Ford...2014 4. TITLE AND SUBTITLE Potential Cost Savings with 3D Printing Combined With 3D Imaging and CPLM for Fleet Maintenance and Revitalization 5a...Manufacturing ( 3D printing ) 2 Research Context Problem: Learning curve savings forecasted in SHIPMAIN maintenance initiative have not materialized

  10. Capital and Operating Costs of Full-Scale Fecal Sludge Management and Wastewater Treatment Systems in Dakar, Senegal

    Science.gov (United States)

    2012-01-01

    A financial comparison of a parallel sewer based (SB) system with activated sludge, and a fecal sludge management (FSM) system with onsite septic tanks, collection and transport (C&T) trucks, and drying beds was conducted. The annualized capital for the SB ($42.66 capita–1 year–1) was ten times higher than the FSM ($4.05 capita–1 year–1), the annual operating cost for the SB ($11.98 capita–1 year–1) was 1.5 times higher than the FSM ($7.58 capita–1 year–1), and the combined capital and operating for the SB ($54.64 capita–1 year–1) was five times higher than FSM ($11.63 capita–1 year–1). In Dakar, costs for SB are almost entirely borne by the sanitation utility, with only 6% of the annualized cost borne by users of the system. In addition to costing less overall, FSM operates with a different business model, with costs spread among households, private companies, and the utility. Hence, SB was 40 times more expensive to implement for the utility than FSM. However, the majority of FSM costs are borne at the household level and are inequitable. The results of the study illustrate that in low-income countries, vast improvements in sanitation can be affordable when employing FSM, whereas SB systems are prohibitively expensive. PMID:22413875

  11. Capital and operating costs of full-scale fecal sludge management and wastewater treatment systems in Dakar, Senegal.

    Science.gov (United States)

    Dodane, Pierre-Henri; Mbéguéré, Mbaye; Sow, Ousmane; Strande, Linda

    2012-04-03

    A financial comparison of a parallel sewer based (SB) system with activated sludge, and a fecal sludge management (FSM) system with onsite septic tanks, collection and transport (C&T) trucks, and drying beds was conducted. The annualized capital for the SB ($42.66 capita(-1) year(-1)) was ten times higher than the FSM ($4.05 capita(-1) year(-1)), the annual operating cost for the SB ($11.98 capita(-1) year(-1)) was 1.5 times higher than the FSM ($7.58 capita(-1) year(-1)), and the combined capital and operating for the SB ($54.64 capita(-1) year(-1)) was five times higher than FSM ($11.63 capita(-1) year(-1)). In Dakar, costs for SB are almost entirely borne by the sanitation utility, with only 6% of the annualized cost borne by users of the system. In addition to costing less overall, FSM operates with a different business model, with costs spread among households, private companies, and the utility. Hence, SB was 40 times more expensive to implement for the utility than FSM. However, the majority of FSM costs are borne at the household level and are inequitable. The results of the study illustrate that in low-income countries, vast improvements in sanitation can be affordable when employing FSM, whereas SB systems are prohibitively expensive.

  12. A Novel Pumped Hydro Combined with Compressed Air Energy Storage System

    Directory of Open Access Journals (Sweden)

    Erren Yao

    2013-03-01

    Full Text Available A novel pumped hydro combined with compressed air energy storage (PHCA system is proposed in this paper to resolve the problems of bulk energy storage in the wind power generation industry over an area in China, which is characterised by drought and water shortages. Thermodynamic analysis of the energy storage system, which focuses on the pre-set pressure, storage volume capacity, water air volume ratio, pump performance, and water turbine performance of the storage system, is also presented. This paper discovers how such parameters affect the performance of the whole system. The ideal performance of this novel system has the following advantages: a simple, highly effective and low cost structure, which is comparable to the efficiency of a traditional pumped hydro storage system. Research results show a great solution to the current storage constraints encountered in the development of the wind power industry in China, which have been widely recognised as a bottleneck in the wind energy storage industry.

  13. Total cost of ownership of CHP SOFC systems: Effect of installation context

    International Nuclear Information System (INIS)

    Arduino, Francesco; Santarelli, Massimo

    2016-01-01

    Solid oxide fuel cells (SOFC) are one of the most interesting between the emerging technologies for energy production. Although some information about the production cost of these devices are already known, their operational cost has not been studied yet with sufficient accuracy. This paper presents a life cycle cost (LCC) analysis of CHP (combined heat and power) SOFC systems performed in hospitals located in various cities of the US and one in Italy. In this study the strong effects of the installation context will be analyzed using a customized use phase model for each location. The cost effectiveness of these devices has been proved without credits in Mondovi (IT), New York (NY) and Minneapolis (MN) where the payback time goes from 10 to 7 years. Considering the credits, it is possible to obtain economic feasibility also in Chicago (IL) and reduce the payback for other cities to values from 4 to 6 years. In other cities like Phoenix (AZ) and Houston (TX) the payback can’t be reached in any case. The life cycle impact assessment analysis has shown how, even in the cities with cleaner electricity grid, there is a reduction in the emissions of both greenhouse gases and pollutants. - Highlights: •Life cycle cost analysis has been performed for CHP SOFC systems. •The strong effects of the installation context have been analyzed. •Economic feasibility has been proven in new york, Minneapolis and Mondovi. •Economic feasibility can’t be reached in phoenix and Houston. •SOFC always provide a reduction in the emissions of greenhouse gases and pollutant.

  14. Fuel cell system economics: comparing the costs of generating power with stationary and motor vehicle PEM fuel cell systems

    International Nuclear Information System (INIS)

    Lipman, Timothy E.; Edwards, Jennifer L.; Kammen, Daniel M.

    2004-01-01

    This investigation examines the economics of producing electricity from proton-exchange membrane (PEM) fuel cell systems under various conditions, including the possibility of using fuel cell vehicles (FCVs) to produce power when they are parked at office buildings and residences. The analysis shows that the economics of both stationary fuel cell and FCV-based power vary significantly with variations in key input variables such as the price of natural gas, electricity prices, fuel cell and reformer system costs, and fuel cell system durability levels. The 'central case' results show that stationary PEM fuel cell systems can supply electricity for offices and homes in California at a net savings when fuel cell system costs reach about $6000 for a 5 kW home system ($1200/kW) and $175,000 for a 250 kW commercial system ($700/kW) and assuming somewhat favorable natural gas costs of $6/GJ at residences and $4/GJ at commercial buildings. Grid-connected FCVs in commercial settings can also potentially supply electricity at competitive rates, in some cases producing significant annual benefits. Particularly attractive is the combination of net metering along with time-of-use electricity rates that allow power to be supplied to the utility grid at the avoided cost of central power plant generation. FCV-based power at individual residences does not appear to be as attractive, at least where FCV power can only be used directly or banked with the utility for net metering and not sold in greater quantity, due to the low load levels at these locations that provide a poor match to automotive fuel cell operation, higher natural gas prices than are available at commercial settings, and other factors

  15. Utilization of municipal wastewater for cooling in thermoelectric power plants: Evaluation of the combined cost of makeup water treatment and increased condenser fouling

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Michael E. [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Theregowda, Ranjani B. [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept of Civil and Mechanical Engineering; Safari, Iman [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Abbasian, Javad [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Arastoopour, Hamid [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Dzombak, David A. [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept of Civil and Mechanical Engineering; Hsieh, Ming-Kai [Tamkang Univ., Taipei (Taiwan). Waer Resources Management and Policy Research Center; Miller, David C. [National Energy Technology Lab. (NETL), Morgantown, WV (United States)

    2013-10-01

    A methodology is presented to calculate the total combined cost (TCC) of water sourcing, water treatment and condenser fouling in the recirculating cooling systems of thermoelectric power plants. The methodology is employed to evaluate the economic viability of using treated municipal wastewater (MWW) to replace the use of freshwater as makeup water to power plant cooling systems. Cost analyses are presented for a reference power plant and five different tertiary treatment scenarios to reduce the scaling tendencies of MWW. Results indicate that a 550 MW sub-critical coal fired power plant with a makeup water requirement of 29.3 ML/day has a TCC of $3.0 - 3.2 million/yr associated with the use of treated MWW for cooling. (All costs USD 2009). This translates to a freshwater conservation cost of $0.29/kL, which is considerably lower than that of dry air cooling technology, $1.5/kL, as well as the 2020 conservation cost target set by the U.S. Department of Energy, $0.74/kL. Results also show that if the available price of freshwater exceeds that of secondary-treated MWW by more than $0.13-0.14/kL, it can be economically advantageous to purchase secondary MWW and treat it for utilization in the recirculating cooling system of a thermoelectric power plant.

  16. Computerized management report system for monitoring manpower and cost

    International Nuclear Information System (INIS)

    Bullington, V.R.; Stephenson, R.L.; Cardwell, R.G.

    1980-04-01

    Although most cost systems offer complete detail and traceability, not all provide timely detail in a concise form useful to senior management. This system was developed for a multifunction research organization funded from many sources. It extracts cost and manpower data from the general cost systems, summarizes it, compares it by program with previous cost periods, and presents it with minimum detail yet with maximum overview. The system monitors the basic manpower distribution of effort at the source, that is, the division time-card input. Cost data are taken from the central computer ahead of the print-out and report-distribution steps; thus, the summary information is available several days ahead of the detailed reports. This procedure has been regularly used for several months, and has proven to be a valuable tool in management action and planning. 9 figures

  17. Value and cost analyses for solar thermal-storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Luft, W.; Copeland, R.J.

    1983-04-01

    Value and cost data for thermal energy storage are presented for solar thermal central receiver systems for which thermal energy storage appears to be attractive. Both solar thermal electric power and industrial process heat applications are evaluated. The value of storage is based on the cost for fossil fuel and solar thermal collector systems in 1990. The costing uses a standard lifetime methodology with the storage capacity as a parameter. Both value and costs are functions of storage capacity. However, the value function depends on the application. Value/cost analyses for first-generation storage concepts for five central receiver systems (molten salt, water/steam, organic fluid, air, and liquid metal) established the reference against which new systems were compared. Some promising second-generation energy storage concepts have been identified, and some more advanced concepts have also been evaluated.

  18. Low Cost Vision Based Personal Mobile Mapping System

    Science.gov (United States)

    Amami, M. M.; Smith, M. J.; Kokkas, N.

    2014-03-01

    Mobile mapping systems (MMS) can be used for several purposes, such as transportation, highway infrastructure mapping and GIS data collecting. However, the acceptance of these systems is not wide spread and their use is still limited due the high cost and dependency on the Global Navigation Satellite System (GNSS). A low cost vision based personal MMS has been produced with an aim to overcome these limitations. The system has been designed to depend mainly on cameras and use of low cost GNSS and inertial sensors to provide a bundle adjustment solution with initial values. The system has the potential to be used indoor and outdoor. The system has been tested indoors and outdoors with different GPS coverage, surrounded features, and narrow and curvy paths. Tests show that the system is able to work in such environments providing 3D coordinates of better than 10 cm accuracy.

  19. Low Cost Vision Based Personal Mobile Mapping System

    Directory of Open Access Journals (Sweden)

    M. M. Amami

    2014-03-01

    Full Text Available Mobile mapping systems (MMS can be used for several purposes, such as transportation, highway infrastructure mapping and GIS data collecting. However, the acceptance of these systems is not wide spread and their use is still limited due the high cost and dependency on the Global Navigation Satellite System (GNSS. A low cost vision based personal MMS has been produced with an aim to overcome these limitations. The system has been designed to depend mainly on cameras and use of low cost GNSS and inertial sensors to provide a bundle adjustment solution with initial values. The system has the potential to be used indoor and outdoor. The system has been tested indoors and outdoors with different GPS coverage, surrounded features, and narrow and curvy paths. Tests show that the system is able to work in such environments providing 3D coordinates of better than 10 cm accuracy.

  20. Development of hospital data warehouse for cost analysis of DPC based on medical costs.

    Science.gov (United States)

    Muranaga, F; Kumamoto, I; Uto, Y

    2007-01-01

    To develop a data warehouse system for cost analysis, based on the categories of the diagnosis procedure combination (DPC) system, in which medical costs were estimated by DPC category and factors influencing the balance between costs and fees. We developed a data warehouse system for cost analysis using data from the hospital central data warehouse system. The balance data of patients who were discharged from Kagoshima University Hospital from April 2003 to March 2005 were determined in terms of medical procedure, cost per day and patient admission in order to conduct a drill-down analysis. To evaluate this system, we analyzed cash flow by DPC category of patients who were categorized as having malignant tumors and whose DPC category was reevaluated in 2004. The percentages of medical expenses were highest in patients with acute leukemia, non-Hodgkin's lymphoma, and particularly in patients with malignant tumors of the liver and intrahepatic bile duct. Imaging tests degraded the percentages of medical expenses in Kagoshima University Hospital. These results suggested that cost analysis by patient is important for hospital administration in the inclusive evaluation system using a case-mix index such as DPC.

  1. Concept and applicability of the KAMEDIN teleradiology system in view of a cost-benefit analysis

    International Nuclear Information System (INIS)

    Lehmann, K.J.; Walz, M.; Bolte, R.; Georgi, M.; Schinkmann, M.; Busch, C.

    1997-01-01

    Introduction: Different concepts and applications of teleradiology systems have been realised. However, their cost-effectiveness is still questionable. Therefore, a cost-benefit analysis of three different scenarios of the new teleradiology system Kamedin (Kooperatives Arbeiten und rechnergestuetzte Medizinische Diagnostik auf innovativen Netzen der Deutschen Telekom) was performed. Methods: CT examinations were transmitted from an Advantage Windows (GE) workstation to a Kamedin workstation using DICOM 3 protocol. Afterwards a teleconference was established with a Kamedin workstation in the intensive care unit within the hospital via FDDI/Ethernet, with an external workstation in a radiology department 6 km away via ISDN and with a Kamedin PC located with radiologist on duty 22 km away via ISDN. On average, 36 CT slices per patient were transferred. A break-even analysis was performed with respect to costs of hardware, software, support, use of ISDN and staff, as well benefits like the decrease in transportation or film documentation costs. Results: Owing to the different reductions in transportation costs, two applications (intensive care unit and external PC) showed a break-even of 1817 and 528 teleconferences/year, respectively. Further optimisation of cost-effectiveness is possible on condition that existing hardware can be used and an automatic data transfer without staff control is available. When all optimisation factors were combined, the break-even decreased to a minimum of 167 and 77 teleconferences/year, respectively. Conclusion: Teleconferences with high image quality can be set up between workstations and PCs using the Kamedin system. Depending on the possible decrease in transportation costs, teleconferencing is cost-effective under certain conditions. Teleradiology has additional advantages, such as the acceleration and optimisation of patient management. (orig.) [de

  2. Combined radar and telemetry system

    Energy Technology Data Exchange (ETDEWEB)

    Rodenbeck, Christopher T.; Young, Derek; Chou, Tina; Hsieh, Lung-Hwa; Conover, Kurt; Heintzleman, Richard

    2017-08-01

    A combined radar and telemetry system is described. The combined radar and telemetry system includes a processing unit that executes instructions, where the instructions define a radar waveform and a telemetry waveform. The processor outputs a digital baseband signal based upon the instructions, where the digital baseband signal is based upon the radar waveform and the telemetry waveform. A radar and telemetry circuit transmits, simultaneously, a radar signal and telemetry signal based upon the digital baseband signal.

  3. Effects of housing system on the costs of commercial egg production.

    Science.gov (United States)

    Matthews, W A; Sumner, D A

    2015-03-01

    This article reports the first publicly available egg production costs compared across 3 hen-housing systems. We collected detailed data from 2 flock cycles from a commercial egg farm operating a conventional barn, an aviary, and an enriched colony system at the same location. The farm employed the same operational and accounting procedures for each housing system. Results provide clear evidence that egg production costs are much higher for the aviary system than the other 2 housing systems. Feed costs per dozen eggs are somewhat higher for the aviary and lower for the enriched house compared with the conventional house. Labor costs are much lower for the conventional house than the other 2, and pullet costs are much higher for the aviary. Energy and miscellaneous costs are a minimal part of total operating costs and do not differ by housing system. Total capital investments per hen-capacity are much higher for the aviary and the enriched house. Capital costs per dozen eggs depend on assumptions about appropriate interest and depreciation rates. Using the same 10% rate for each housing system shows capital costs per dozen for the aviary and the enriched housing system are much higher than capital costs per dozen for the conventional house. The aviary has average operating costs (feed, labor, pullet, energy, and miscellaneous costs that recur for each flock and vary with egg production) about 23% higher and average total costs about 36% higher compared with the conventional house. The enriched housing system has average operating costs only about 4% higher compared with the conventional house, but average total costs are 13% higher than for the conventional house. © The Author 2015. Published by Oxford University Press on behalf of Poultry Science Association.

  4. Energy storage systems cost update : a study for the DOE Energy Storage Systems Program.

    Energy Technology Data Exchange (ETDEWEB)

    Schoenung, Susan M. (Longitude 122 West, Menlo Park, CA)

    2011-04-01

    This paper reports the methodology for calculating present worth of system and operating costs for a number of energy storage technologies for representative electric utility applications. The values are an update from earlier reports, categorized by application use parameters. This work presents an update of energy storage system costs assessed previously and separately by the U.S. Department of Energy (DOE) Energy Storage Systems Program. The primary objective of the series of studies has been to express electricity storage benefits and costs using consistent assumptions, so that helpful benefit/cost comparisons can be made. Costs of energy storage systems depend not only on the type of technology, but also on the planned operation and especially the hours of storage needed. Calculating the present worth of life-cycle costs makes it possible to compare benefit values estimated on the same basis.

  5. Thermoeconomic Modeling and Parametric Study of a Photovoltaic-Assisted 1 MWe Combined Cooling, Heating, and Power System

    Directory of Open Access Journals (Sweden)

    Alexandros Arsalis

    2016-08-01

    Full Text Available In this study a small-scale, completely autonomous combined cooling, heating, and power (CCHP system is coupled to a photovoltaic (PV subsystem, to investigate the possibility of reducing fuel consumption. The CCHP system generates electrical energy with the use of a simple gas turbine cycle, with a rated nominal power output of 1 MWe. The nominal power output of the PV subsystem is examined in a parametric study, ranging from 0 to 600 kWe, to investigate which configuration results in a minimum lifecycle cost (LCC for a system lifetime of 20 years of service. The load profile considered is applied for a complex of households in Nicosia, Cyprus. The solar data for the PV subsystem are taken on an hourly basis for a whole year. The results suggest that apart from economic benefits, the proposed system also results in high efficiency and reduced CO2 emissions. The parametric study shows that the optimum PV capacity is 300 kWe. The minimum lifecycle cost for the PV-assisted CCHP system is found to be 3.509 million €, as compared to 3.577 million € for a system without a PV subsystem. The total cost for the PV subsystem is 547,445 €, while the total cost for operating the system (fuel is 731,814 € (compared to 952,201 € for a CCHP system without PVs. Overall the proposed system generates a total energy output of 210,520 kWh (during its whole lifetime, which translates to a unit cost of 17 €/kWh.

  6. Autonomous grain combine control system

    Science.gov (United States)

    Hoskinson, Reed L.; Kenney, Kevin L.; Lucas, James R.; Prickel, Marvin A.

    2013-06-25

    A system for controlling a grain combine having a rotor/cylinder, a sieve, a fan, a concave, a feeder, a header, an engine, and a control system. The feeder of the grain combine is engaged and the header is lowered. A separator loss target, engine load target, and a sieve loss target are selected. Grain is harvested with the lowered header passing the grain through the engaged feeder. Separator loss, sieve loss, engine load and ground speed of the grain combine are continuously monitored during the harvesting. If the monitored separator loss exceeds the selected separator loss target, the speed of the rotor/cylinder, the concave setting, the engine load target, or a combination thereof is adjusted. If the monitored sieve loss exceeds the selected sieve loss target, the speed of the fan, the size of the sieve openings, or the engine load target is adjusted.

  7. Airbreathing combined cycle engine systems

    Science.gov (United States)

    Rohde, John

    1992-01-01

    The Air Force and NASA share a common interest in developing advanced propulsion systems for commercial and military aerospace vehicles which require efficient acceleration and cruise operation in the Mach 4 to 6 flight regime. The principle engine of interest is the turboramjet; however, other combined cycles such as the turboscramjet, air turborocket, supercharged ejector ramjet, ejector ramjet, and air liquefaction based propulsion are also of interest. Over the past months careful planning and program implementation have resulted in a number of development efforts that will lead to a broad technology base for those combined cycle propulsion systems. Individual development programs are underway in thermal management, controls materials, endothermic hydrocarbon fuels, air intake systems, nozzle exhaust systems, gas turbines and ramjet ramburners.

  8. Thermo economic comparison of conventional micro combined heat and power systems with solid oxide fuel cell systems for small scale applications

    DEFF Research Database (Denmark)

    Batens, Ellen; Cuellar, Rafael; Marissal, Matthieu

    2013-01-01

    out a thermo economic comparison of a conventional micro combined heat and power systems with solid oxide fuel cell systems. A model to estimate the savings and cost targets for solid oxide fuel cell systems is presented. A comparison between fuel cell technologies in the danish market with “state......Fuel cells have the potential to reduce domestic energy consumption by providing both heat and electricity at the point of use. However, the cost of installing the fuel cell must be sufficiently competitive to be recovered by the savings made over its lifetime. The goal of this paper is to carry...... of the art” traditional heat and power generation technologies currently used in Denmark is considered. The conventional method of covering electrical, heating (e.g. hot water) and cooling (e.g. space cooling) load demands is by purchasing electricity from the electricity network grid and with a fossil fuel...

  9. Energy and cost saving results for advanced technology systems from the Cogeneration Technology Alternatives Study (CTAS)

    Science.gov (United States)

    Sagerman, G. D.; Barna, G. J.; Burns, R. K.

    1979-01-01

    An overview of the organization and methodology of the Cogeneration Technology Alternatives Study is presented. The objectives of the study were to identify the most attractive advanced energy conversion systems for industrial cogeneration applications in the future and to assess the advantages of advanced technology systems compared to those systems commercially available today. Advanced systems studied include steam turbines, open and closed cycle gas turbines, combined cycles, diesel engines, Stirling engines, phosphoric acid and molten carbonate fuel cells and thermionics. Steam turbines, open cycle gas turbines, combined cycles, and diesel engines were also analyzed in versions typical of today's commercially available technology to provide a base against which to measure the advanced systems. Cogeneration applications in the major energy consuming manufacturing industries were considered. Results of the study in terms of plant level energy savings, annual energy cost savings and economic attractiveness are presented for the various energy conversion systems considered.

  10. The promise--and peril--of integrated cost systems.

    Science.gov (United States)

    Cooper, R; Kaplan, R S

    1998-01-01

    Recent advances in managerial accounting have helped executives get the information they need to make good strategic decisions. But today's enterprise resource planning systems promise even greater benefits--the chance to integrate activity-based costing, operational-control, and financial reporting systems. But managers need to approach integration very thoughtfully, or they could end up with a system that drives decision making in the wrong direction. Operational-control and ABC systems have fundamentally different purposes. Their requirements for accuracy, timeliness, and aggregation are so different that no single, fully integrated approach can be adequate for both purposes. If an integrated system used real-time cost data instead of standard rates in its ABC subsystem, for example, the result would be dangerously distorted messages about individual product profitability--and that's precisely the problem ABC systems were originally designed to address. Proper linkage and feedback between the two systems is possible, however. Through activity-based budgeting, the ABC system is linked directly to operations control: managers can determine the supply and practical capacity of resources in forthcoming periods. Linking operational control to ABC is also possible. The activity-based portion of an operational control system collects information that, while it mustn't be fed directly into the activity-based strategic cost system, can be extremely useful once it's been properly analyzed. Finally, ABC and operational control can be linked to financial reporting to generate cost of goods sold and inventory valuations--but again, with precautions.

  11. 4E analysis and multi objective optimization of a micro gas turbine and solid oxide fuel cell hybrid combined heat and power system

    Science.gov (United States)

    Sanaye, Sepehr; Katebi, Arash

    2014-02-01

    Energy, exergy, economic and environmental (4E) analysis and optimization of a hybrid solid oxide fuel cell and micro gas turbine (SOFC-MGT) system for use as combined generation of heat and power (CHP) is investigated in this paper. The hybrid system is modeled and performance related results are validated using available data in literature. Then a multi-objective optimization approach based on genetic algorithm is incorporated. Eight system design parameters are selected for the optimization procedure. System exergy efficiency and total cost rate (including capital or investment cost, operational cost and penalty cost of environmental emissions) are the two objectives. The effects of fuel unit cost, capital investment and system power output on optimum design parameters are also investigated. It is observed that the most sensitive and important design parameter in the hybrid system is fuel cell current density which has a significant effect on the balance between system cost and efficiency. The selected design point from the Pareto distribution of optimization results indicates a total system exergy efficiency of 60.7%, with estimated electrical energy cost 0.057 kW-1 h-1, and payback period of about 6.3 years for the investment.

  12. The cost of silage harvest and transport systems for herbaceous crops

    Energy Technology Data Exchange (ETDEWEB)

    Turhollow, A.; Downing, M. [Oak Ridge National Lab., TN (United States); Butler, J. [Butler (James), Tifton, GA (United States)

    1996-12-31

    Some of the highest yielding herbaceous biomass crops are thick- stemmed species. Their relatively high moisture content necessitates they be handled and stored as silage rather than hay bales or modules. This paper presents estimated costs of harvesting and transporting herbaceous crops as silage. Costs are based on an engineering- economic approach. Equipment costs are estimated by combining per hour costs with the hours required to complete the operation. Harvest includes severing, chopping, and blowing stalks into a wagon or truck.

  13. A cost optimization model for 100% renewable residential energy supply systems

    DEFF Research Database (Denmark)

    Milan, Christian; Bojesen, Carsten; Nielsen, Mads Pagh

    2012-01-01

    The concept of net zero energy buildings (Net ZEB) has received increased attention throughout the last years. A well adapted and optimized design of the energy supply system is crucial for the performance of these buildings. To achieve this, a holistic approach is needed which accounts for the i......The concept of net zero energy buildings (Net ZEB) has received increased attention throughout the last years. A well adapted and optimized design of the energy supply system is crucial for the performance of these buildings. To achieve this, a holistic approach is needed which accounts......'s involving on-site production of heat and electricity in combination with electricity exchanged with the public grid. The model is based on linear programming and determines the optimal capacities for each relevant supply technology in terms of the overall system costs. It has been successfully applied...

  14. The cost-effectiveness and return-on-investment of a combined social and physical environmental intervention in office employees

    NARCIS (Netherlands)

    van Dongen, J M; Coffeng, J K; van Wier, M F; Boot, Cecile R. L.; Hendriksen, I.J.M.; van Mechelen, W.; Bongers, Paulien M.; Van Der Beek, Allard J.; Bosmans, J E; van Tulder, M W

    2017-01-01

    This study explored the cost-effectiveness and return-on-investment of a combined social and physical environmental worksite health promotion program compared with usual practice, and of both intervention conditions separately. Participants were randomized to the combined intervention (n = 92),

  15. Opportunities and challenges for implementing cost accounting systems in the Kenyan health system

    Directory of Open Access Journals (Sweden)

    Elesban Kihuba

    2016-06-01

    Full Text Available Background: Low- and middle-income countries need to sustain efficiency and equity in health financing on their way to universal health care coverage. However, systems meant to generate quality economic information are often deficient in such settings. We assessed the feasibility of streamlining cost accounting systems within the Kenyan health sector to illustrate the pragmatic challenges and opportunities. Design: We reviewed policy documents, and conducted field observations and semi-structured interviews with key informants in the health sector. We used an adapted Human, Organization and Technology fit (HOT-fit framework to analyze the components and standards of a cost accounting system. Results: Among the opportunities for a viable cost accounting system, we identified a supportive broad policy environment, political will, presence of a national data reporting architecture, good implementation experience with electronic medical records systems, and the availability of patient clinical and resource use data. However, several practical issues need to be considered in the design of the system, including the lack of a framework to guide the costing process, the lack of long-term investment, the lack of appropriate incentives for ground-level staff, and a risk of overburdening the current health management information system. Conclusion: To facilitate the implementation of cost accounting into the health sector, the design of any proposed system needs to remain simple and attuned to the local context.

  16. Opportunities and challenges for implementing cost accounting systems in the Kenyan health system

    Science.gov (United States)

    Kihuba, Elesban; Gheorghe, Adrian; Bozzani, Fiammetta; English, Mike; Griffiths, Ulla K.

    2016-01-01

    Background Low- and middle-income countries need to sustain efficiency and equity in health financing on their way to universal health care coverage. However, systems meant to generate quality economic information are often deficient in such settings. We assessed the feasibility of streamlining cost accounting systems within the Kenyan health sector to illustrate the pragmatic challenges and opportunities. Design We reviewed policy documents, and conducted field observations and semi-structured interviews with key informants in the health sector. We used an adapted Human, Organization and Technology fit (HOT-fit) framework to analyze the components and standards of a cost accounting system. Results Among the opportunities for a viable cost accounting system, we identified a supportive broad policy environment, political will, presence of a national data reporting architecture, good implementation experience with electronic medical records systems, and the availability of patient clinical and resource use data. However, several practical issues need to be considered in the design of the system, including the lack of a framework to guide the costing process, the lack of long-term investment, the lack of appropriate incentives for ground-level staff, and a risk of overburdening the current health management information system. Conclusion To facilitate the implementation of cost accounting into the health sector, the design of any proposed system needs to remain simple and attuned to the local context. PMID:27357072

  17. Opportunities and challenges for implementing cost accounting systems in the Kenyan health system.

    Science.gov (United States)

    Kihuba, Elesban; Gheorghe, Adrian; Bozzani, Fiammetta; English, Mike; Griffiths, Ulla K

    2016-01-01

    Low- and middle-income countries need to sustain efficiency and equity in health financing on their way to universal health care coverage. However, systems meant to generate quality economic information are often deficient in such settings. We assessed the feasibility of streamlining cost accounting systems within the Kenyan health sector to illustrate the pragmatic challenges and opportunities. We reviewed policy documents, and conducted field observations and semi-structured interviews with key informants in the health sector. We used an adapted Human, Organization and Technology fit (HOT-fit) framework to analyze the components and standards of a cost accounting system. Among the opportunities for a viable cost accounting system, we identified a supportive broad policy environment, political will, presence of a national data reporting architecture, good implementation experience with electronic medical records systems, and the availability of patient clinical and resource use data. However, several practical issues need to be considered in the design of the system, including the lack of a framework to guide the costing process, the lack of long-term investment, the lack of appropriate incentives for ground-level staff, and a risk of overburdening the current health management information system. To facilitate the implementation of cost accounting into the health sector, the design of any proposed system needs to remain simple and attuned to the local context.

  18. Joint Planning Of Energy Storage and Transmission Considering Wind-Storage Combined System and Demand Side Response

    Science.gov (United States)

    Huang, Y.; Liu, B. Z.; Wang, K. Y.; Ai, X.

    2017-12-01

    In response to the new requirements of the operation mode of wind-storage combined system and demand side response for transmission network planning, this paper presents a joint planning of energy storage and transmission considering wind-storage combined system and demand side response. Firstly, the charge-discharge strategy of energy storage system equipped at the outlet of wind farm and demand side response strategy are analysed to achieve the best comprehensive benefits through the coordination of the two. Secondly, in the general transmission network planning model with wind power, both energy storage cost and demand side response cost are added to the objective function. Not only energy storage operation constraints and but also demand side response constraints are introduced into the constraint condition. Based on the classical formulation of TEP, a new formulation is developed considering the simultaneous addition of the charge-discharge strategy of energy storage system equipped at the outlet of the wind farm and demand side response strategy, which belongs to a typical mixed integer linear programming model that can be solved by mature optimization software. The case study based on the Garver-6 bus system shows that the validity of the proposed model is verified by comparison with general transmission network planning model. Furthermore, the results demonstrate that the joint planning model can gain more economic benefits through setting up different cases.

  19. Subsystem cost data for the tritium systems test assembly

    International Nuclear Information System (INIS)

    Bartlit, J.R.; Anderson, J.L.; Rexroth, V.G.

    1983-01-01

    Details of subsystem costs are among the questions most frequently asked about the $14.4 million Tritium Systems Test Assembly (TSTA) at Los Alamos National Laboratory. This paper presents a breakdown of cost components for each of the 20 major subsystems of TSTA. Also included are details to aid in adjusting the costs to other years, contracting conditions, or system sizes

  20. Combining Time-Driven Activity-Based Costing with Clinical Outcome in Cost-Effectiveness Analysis to Measure Value in Treatment of Depression.

    Science.gov (United States)

    El Alaoui, Samir; Lindefors, Nils

    2016-01-01

    of full remission using psychologists instead of medical specialists for post-treatment assessment is cost-saving and consequently a more valuable use of limited resources. TDABC may be a useful tool for measuring resource costs, identifying quality improvement opportunities and evaluating the consequences of such initiatives. Combining TDABC with clinical outcome measures in CEA is potentially a useful approach in mental healthcare to estimate the value of process improvement initiatives.

  1. (Reportıng of Operation Results In Basis Of Actual Variable Cost)

    OpenAIRE

    Çıkrıkçı, Mustafa; Dabbağoğlu, Kadir

    2007-01-01

    Calculation of production cost is primarily, essential to calculate cost of sales. Production cost is in the field of cost accounting and there are different approaches on calculation of production cost in cost accounting theory. These approaches designate the cost system. A cost system is a combination of cost principle, cost method and cost procedure. Principals consist of full cost and partial cost. Methods consist of actual cost and estimated cost. Procedures consist of order cost and sta...

  2. Harvesting systems and costs for southern pine in the 1980s

    Science.gov (United States)

    Frederick W. Cubbage; James E. Granskog

    1981-01-01

    Timber harvesting systems and their costs are a major concern for the forest products industries. In this paper, harvest costs per cord are estimated, using computer simulation, for current southern pine harvesting systems. The estimations represent a range of mechanization levels. The sensitivity of systems to factors affecting harvest costs - machine costs, fuel...

  3. Design optimization and sensitivity analysis of a biomass-fired combined cooling, heating and power system with thermal energy storage systems

    International Nuclear Information System (INIS)

    Caliano, Martina; Bianco, Nicola; Graditi, Giorgio; Mongibello, Luigi

    2017-01-01

    Highlights: • A novel operation strategy for biomass-fired combined cooling, heating and power system is presented. • A design optimization of the system is conducted. • The effects of variation of the incentive for the electricity generation are evaluated. • The effects of the variation of the absorption chiller size and the thermal energy storage system one are evaluated. • The inclusion of a cold storage system into the combined cooling, heating and power system is also analyzed. - Abstract: In this work, an operation strategy for a biomass-fired combined cooling, heating and power system, composed of a cogeneration unit, an absorption chiller, and a thermal energy storage system, is formulated in order to satisfy time-varying energy demands of an Italian cluster of residential multi-apartment buildings. This operation strategy is adopted for performing the economical optimization of the design of two of the devices composing the combined cooling, heating and power system, namely the absorption chiller and the storage system. A sensitivity analysis is carried out in order to evaluate the impact of the incentive for the electricity generation on the optimized results, and also to evaluate, separately, the effects of the variation of the absorption chiller size, and the effects of the variation of the thermal energy storage system size on the system performance. In addition, the inclusion into the system of a cold thermal energy storage system is analyzed, as well, assuming different possible values for the cold storage system cost. The results of the sensitivity analysis indicate that the most influencing factors from the economical point of view are represented by the incentive for the electricity generation and the absorption chiller power. Results also show that the combined use of a thermal energy storage and of a cold thermal energy storage during the hot season could represent a viable solution from the economical point of view.

  4. Recent evolutions in costing systems: A literature review of Time-Driven Activity-Based Costing

    OpenAIRE

    Siguenza Guzman, Lorena; Van den Abbeele, Alexandra; Vandewalle, Joos; Verhaaren, Henry; Cattrysse, Dirk

    2013-01-01

    This article provides a comprehensive literature review of Time-Driven Activity Based Costing (TDABC), a relatively new tool to improve the cost allocation to products and services. After a brief overview of traditional costing and activity based costing systems (ABC), a detailed description of the TDABC model is given and a comparison made between this methodology and its predecessor ABC. Thirty-six empirical contributions using TDABC over the period 2004-2012 were reviewed. The results and ...

  5. Waste management facilities cost information: System cost model product description. Revision 2

    International Nuclear Information System (INIS)

    Lundeen, A.S.; Hsu, K.M.; Shropshire, D.E.

    1996-02-01

    In May of 1994, Lockheed Idaho Technologies Company (LITCO) in Idaho Falls, Idaho and subcontractors developed the System Cost Model (SCM) application. The SCM estimates life-cycle costs of the entire US Department of Energy (DOE) complex for designing; constructing; operating; and decommissioning treatment, storage, and disposal (TSD) facilities for mixed low-level, low-level, transuranic, and mixed transuranic waste. The SCM uses parametric cost functions to estimate life-cycle costs for various treatment, storage, and disposal modules which reflect planned and existing facilities at DOE installations. In addition, SCM can model new facilities based on capacity needs over the program life cycle. The SCM also provides transportation costs for DOE wastes. Transportation costs are provided for truck and rail and include transport of contact-handled, remote-handled, and alpha (transuranic) wastes. The user can provide input data (default data is included in the SCM) including the volume and nature of waste to be managed, the time period over which the waste is to be managed, and the configuration of the waste management complex (i.e., where each installation's generated waste will be treated, stored, and disposed). Then the SCM uses parametric cost equations to estimate the costs of pre-operations (designing), construction costs, operation management, and decommissioning these waste management facilities

  6. NASA Electronic Publishing System: Cost/benefit Methodology

    Science.gov (United States)

    Tuey, Richard C.

    1994-01-01

    The NASA Scientific and Technical Information Office was assigned the responsibility to examine the benefits of the utilization of electronic printing and duplicating systems throughout NASA Installations and Headquarters. The subject of this report is the documentation of the methodology used in justifying the acquisition of the most cost beneficial solution for the printing and duplicating requirements of a duplicating facility that is contemplating the acquisition of an electronic printing and duplicating system. Four alternatives are presented with each alternative costed out with its associated benefits. The methodology goes a step further than just a cost benefit analysis through its comparison of risks associated with each alternative, sensitivity to number of impressions and productivity gains on the selected alternative and finally the return on investment for the selected alternative. The report can be used in conjunction with the two earlier reports, NASA-TM-106242 and TM-106510 in guiding others in determining the cost effective duplicating alternative.

  7. VIABILITY OF SOME APPLIED COST SYSTEMS IN MANUFACTURING FIRMS: EGYPT'S CASE

    Directory of Open Access Journals (Sweden)

    Karim Mamdouh ABBAS

    2015-04-01

    Full Text Available The present study aims to analyze viability of some applied cost systems. The population of the study is some Egyptian manufacturing firms. The number of received questionnaires was 385. The results indicated that , according to the application extent indicator, the currently cost systems in Egyptian manufacturing firms may be descendingly arranged as follows: Activity Based Costing (ABC system, Target Costing (TC system , Resource Consumption Accounting (RCA system, Activity Based Management (ABM ,Other systems, Theory of Constraints (TOC and Value Chain (VC analysis.

  8. Space construction system analysis. Part 2: Cost and programmatics

    Science.gov (United States)

    Vonflue, F. W.; Cooper, W.

    1980-01-01

    Cost and programmatic elements of the space construction systems analysis study are discussed. The programmatic aspects of the ETVP program define a comprehensive plan for the development of a space platform, the construction system, and the space shuttle operations/logistics requirements. The cost analysis identified significant items of cost on ETVP development, ground, and flight segments, and detailed the items of space construction equipment and operations.

  9. Low-cost attitude determination system using an extended Kalman filter (EKF) algorithm

    Science.gov (United States)

    Esteves, Fernando M.; Nehmetallah, Georges; Abot, Jandro L.

    2016-05-01

    Attitude determination is one of the most important subsystems in spacecraft, satellite, or scientific balloon mission s, since it can be combined with actuators to provide rate stabilization and pointing accuracy for payloads. In this paper, a low-cost attitude determination system with a precision in the order of arc-seconds that uses low-cost commercial sensors is presented including a set of uncorrelated MEMS gyroscopes, two clinometers, and a magnetometer in a hierarchical manner. The faster and less precise sensors are updated by the slower, but more precise ones through an Extended Kalman Filter (EKF)-based data fusion algorithm. A revision of the EKF algorithm fundamentals and its implementation to the current application, are presented along with an analysis of sensors noise. Finally, the results from the data fusion algorithm implementation are discussed in detail.

  10. The Characteristic of Molten Heat Salt Storage System Utilizing Solar Energy Combined with Valley Electric

    Directory of Open Access Journals (Sweden)

    LI .Jiu-ru

    2017-02-01

    Full Text Available With the environmental pollution and energy consumption clue to the large difference between peak and valley of power grid,the molten salt heat storage system(MSHSS utilizing solar Energy combined with valley electric is presented for good energy saving and low emissions. The costs of MSHSS utilizing solar Energy combined with valley electric are greatly reduced. The law of heat transfer in molten salt heat storage technology is studied with the method of grey correlation analysis. The results show the effect of elbow sizes on surface convective heat transfer coefficient with different flow velocities.

  11. A system-level cost-of-energy wind farm layout optimization with landowner modeling

    International Nuclear Information System (INIS)

    Chen, Le; MacDonald, Erin

    2014-01-01

    Highlights: • We model the role of landowners in determining the success of wind projects. • A cost-of-energy (COE) model with realistic landowner remittances is developed. • These models are included in a system-level wind farm layout optimization. • Basic verification indicates the optimal COE is in-line with real-world data. • Land plots crucial to a project’s success can be identified with the approach. - Abstract: This work applies an enhanced levelized wind farm cost model, including landowner remittance fees, to determine optimal turbine placements under three landowner participation scenarios and two land-plot shapes. Instead of assuming a continuous piece of land is available for the wind farm construction, as in most layout optimizations, the problem formulation represents landowner participation scenarios as a binary string variable, along with the number of turbines. The cost parameters and model are a combination of models from the National Renewable Energy Laboratory (NREL), Lawrence Berkeley National Laboratory, and Windustry. The system-level cost-of-energy (COE) optimization model is also tested under two land-plot shapes: equally-sized square land plots and unequal rectangle land plots. The optimal COEs results are compared to actual COE data and found to be realistic. The results show that landowner remittances account for approximately 10% of farm operating costs across all cases. Irregular land-plot shapes are easily handled by the model. We find that larger land plots do not necessarily receive higher remittance fees. The model can help site developers identify the most crucial land plots for project success and the optimal positions of turbines, with realistic estimates of costs and profitability

  12. Dynamic cost control information system for nuclear power plant construction

    International Nuclear Information System (INIS)

    Wang Yongqing; Liu Wei

    1998-01-01

    The authors first introduce the cost control functions of some overseas popular project management software at present and the specific ways of cost control of nuclear power plant construction in China. Then the authors stress the necessity of cost and schedule control integration and present the concept of dynamic cost control, the design scheme of dynamic cost control information system and the data structure modeling. Based on the above, the authors can develop the system which has the functions of dynamic estimate, cash flow management and cost optimization for nuclear engineering

  13. [Fixed drug combinations in hypertension: a budget impact analysis for the Spanish Health System on the marketing of a fixed combination of olmesartan/amlodipine].

    Science.gov (United States)

    Belén Ferro-Rey, M; Roca-Cusachs, Alex; Sicras-Mainar, Antoni; Alvarez-Martín, Carlos; de Salas-Cansado, Marina

    2011-07-01

    To carry out a budget impact analysis (BIA) of olmesartan/amlodipine (20/5, 40/5 and 40/10mg) marketed as a fixed combination (FC) in its approved indication for the National Health System (NHS). We developed a decision tree model in order to estimate usual hypertension treatment algorithm in Spanish clinical practice. The BIA has been developed from the perspective of the NHS for a period of 3 years (years 2010-2012). Spanish hypertensive population ≥ 35 years old. Introduction into the market of a fixed combination (FC) olmesartan/amlodipine in Spain. Expected costs to be assumed by the Spanish NHS (RRP-VAT) for hypertensive population able to be treated with the FC versus currently assumed costs by the NHS with free combination olmesartan and amlodipine. Estimated pharmaceutical costs in hypertensive population treated with olmesartan and amlodipine (2 pills) would be €25.2M (1(st) year), €26.4M (2011), €27.6M (2012), with a total 3-year period of €79.2M. According to patient tree model, the population able to be treated with FC would be 71,283 patients (2010), with a growth rate of 4.8% in the successive years, which supposes an annual cost of €21.2M (2010), €21.8M (2011) and €22.4M (2012), with a total 3-year period of €65.4M. The BIA shows savings of €13.8M in a total 3-year period. The BIA of FC olmesartan/amlodipine could generate net savings of €13.8M for the NHS in the period ranging from years 2010 to 2012. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  14. Development of geological disposal system; localization of element cost data and cost evaluation on the HLW repository

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Sik; Kim, Kil Jung; Yang, Young Jin; Kim, Sung Chun [KOPEC, Taejeon (Korea)

    2002-03-01

    To estimate Total Life Cycle Cost (TSLCC) for Korea HLW Repository through localization of element cost data, we review and re-organize each basic element cost data for reference repository system, localize various element cost and finally estimate TSLCC considering economic parameters. As results of the study, TSLCC is estimated as 17,167,689 million won, which includes costs for site preparation, surface facilities, underground facilities and management/integration. Since HLW repository Project is an early stage of pre-conceptual design at present, the information of design and project information are not enough to perform cost estimate and cost localization for the Project. However, project cost structure is re-organized based on the local condition and Total System Life Cycle Cost is estimated using the previous cost data gathered from construction experience of the local nuclear power plant. Project results can be used as basic reference data to assume total construction cost for the local HLW repository and should be revised to more reliable cost data with incorporating detail project design information into the cost estimate in a future. 20 refs. (Author)

  15. Life cycle cost estimation and systems analysis of Waste Management Facilities

    International Nuclear Information System (INIS)

    Shropshire, D.; Feizollahi, F.

    1995-01-01

    This paper presents general conclusions from application of a system cost analysis method developed by the United States Department of Energy (DOE), Waste Management Division (WM), Waste Management Facilities Costs Information (WMFCI) program. The WMFCI method has been used to assess the DOE complex-wide management of radioactive, hazardous, and mixed wastes. The Idaho Engineering Laboratory, along with its subcontractor Morrison Knudsen Corporation, has been responsible for developing and applying the WMFCI cost analysis method. The cost analyses are based on system planning level life-cycle costs. The costs for life-cycle waste management activities estimated by WMFCI range from bench-scale testing and developmental work needed to design and construct a facility, facility permitting and startup, operation and maintenance, to the final decontamination, decommissioning, and closure of the facility. For DOE complex-wide assessments, cost estimates have been developed at the treatment, storage, and disposal module level and rolled up for each DOE installation. Discussions include conclusions reached by studies covering complex-wide consolidation of treatment, storage, and disposal facilities, system cost modeling, system costs sensitivity, system cost optimization, and the integration of WM waste with the environmental restoration and decontamination and decommissioning secondary wastes

  16. Development of low-cost digital subtraction angiography system

    International Nuclear Information System (INIS)

    Ando, Yutaka; Kobayashi, Takeshi; Imai, Yutaka; Yagishita, Akira; Kunieda, Etsuo.

    1983-01-01

    We developed a simple and low-cost DSA system. This system consists of a conventional fluoroscopic equipment for the GI tract and a mini-computer (GAMMA-11) which are connected each other with a video-disc recorder. The uniqueness of our system are 1. low-cost, 2. low-radiation dose, 3. off-line processing, 4. flexibility of software. The analysis of the time-density curve and image processing will bring us a more usefull information than DSA alone. (author)

  17. The system of account and control of logistics costs

    Directory of Open Access Journals (Sweden)

    Khayrullin Rustam Zinnatullovich

    Full Text Available The process of organization of civil engineering provides the delivery of construction materials, equipment to the civil engineering objects in the required quantities at the specified time. Effective tool for solving this problem is logistics. The basic components of logistics costs, which occupy the largest share in the sum of all logistics costs, are transportation costs and storage costs. The civil engineering industry is very promising for the use of outsourcing. The main part of works on providing material and technical resources in most cases is transferred to the outsourcing of other companies, including the group of companies forming the holding. In large holding companies the chain of movement of materials, goods and productions: purchase of materials and goods, completion materials, production structures, storage, movement, transportation, etc. may include several companies belonging in holding. The goods can be moved from one warehouse to another, with or without change of the owner of goods. Each company is obliged to show each movement of goods in their financial accounting. During the goods’ movement within a group of companies from one storage to another, from one owner to another, the total costs of the goods rise. Sales within a group of companies lead, as a rule, to a gain by one of the companies and the logistic expenses of another company. Selling to a consumer provides a profit to the seller company. Therefore, the problem of adequate allocation of logistics expenses and profits between separate legal entity and the task of continuous accounting and control of logistics costs and earnings in large companies, is vital. The automated system for accounting and controlling of logistics costs is suggested. The developed system allows controlling logistics costs of refining, storage and transportation for each ton, pieces, linear or square meters of the shipped cargoes. The System is based on complex algorithms of distribution

  18. Attributes of system testing which promote cost-effectiveness

    International Nuclear Information System (INIS)

    Martin, L.C.

    1975-01-01

    A brief overview of conventional EMP testing activity examines attributes of overall systems tests which promote cost-effectiveness. The general framework represents an EMP-oriented systems test as a portion of a planned program to design, produce, and field system elements. As such, all so-called system tests should play appropriate cost-effective roles in this program, and the objective here is to disclose such roles. The intrinsic worth of such tests depends not only upon placing proper values on the outcomes, but also upon the possible eventual consequences of not doing tests. A relative worth measure is required. Attributes of EMP system testing over the range of potential activity which encompasses research and development, production, field handling, verification, evaluation, and others are reviewed and examined. Thus, the relative worth, in a cost-effective sense, is provided by relating such attributes to the overall program objectives so that values can be placed on the outcomes for tradeoff purposes

  19. Prototyping low-cost and flexible vehicle diagnostic systems

    Directory of Open Access Journals (Sweden)

    Marisol GARCÍA-VALLS

    2016-12-01

    Full Text Available Diagnostic systems are software and hardware-based equipment that interoperate with an external monitored system. Traditionally, they have been expensive equipment running test algorithms to monitor physical properties of, e.g., vehicles, or civil infrastructure equipment, among others. As computer hardware is increasingly powerful (whereas its cost and size is decreasing and communication software becomes easier to program and more run-time efficient, new scenarios are enabled that yield to lower cost monitoring solutions. This paper presents a low cost approach towards the development of a diagnostic systems relying on a modular component-based approach and running on a resource limited embedded computer. Results on a prototype implementation are shown that validate the presented design, its flexibility, performance, and communication latency.

  20. ILSE combiner study

    International Nuclear Information System (INIS)

    Hahn, K.

    1994-03-01

    In a heavy ion inertial fusion (HIF) driver, the beam energy and current are increased several orders of magnitude from the injector to the final focus system. At low and high energy stages of the driver, electrostatic and magnetic focusing transport channels, respectively, can be used. At the electric-to-magnetic transition point, the beams may be combined to reduce the transverse dimensions of the system, which could have significant impact on the driver cost. In a presently envisioned combiner, four beams are brought together transversely into a single transport channel. A matching section follows the combiner in order to provide a smooth transition to the subsequent magnetic transport channel. This report summarizes a conceptual design study of possible combiner configurations for the proposed Introduction Linac Systems Experiment (ILSE). The conceptual design study includes subjects such as the expected technical difficulties, predicted emittance growth, particle loss, effect of geometric and chromatic aberrations, and the sensitivity of emittance growth on the initial beam position and angle errors

  1. System optimization of solar hydrogen energy system based on hydrogen production cost. 2; Suiso seizo cost wo hyoka shihyo to shita taiyo suiso energy system no saiteki sekkei. 2

    Energy Technology Data Exchange (ETDEWEB)

    Ota, D; Yamagami, Y; Tani, T [Science University of Tokyo, Tokyo (Japan)

    1996-10-27

    In this paper, to evaluate the hydrogen production cost per unit volume, system optimization of solar hydrogen energy system is discussed. Based on the simulation of the I-V characteristics of amorphous Si (a-Si) photovoltaic array, the working point between the array and hydrogen generator was determined. The cost ratio of each design point was calculated. The optimum design points were 500 W/m{sup 2} for the single crystal Si system, and 600 W/m{sup 2} for the a-Si system. When the rating capacity of design point was constant, almost constant cost ratio was obtained independent of the type of photovoltaic cells. It was found that the photovoltaic cells can be fabricated in about 15% lower cost at maximum. It was also found that the optimum design point sifts to the lower insolation site due to reduction of the photovoltaic cell cost. Since the annual hydrogen generation quantity does not depend on the type of photovoltaic cells under the constant rating capacity of design point, hydrogen can be produced in lower cost by using photovoltaic cell of lower cost. 5 refs., 10 figs., 5 tabs.

  2. A Low Cost and High Speed Electrical Capacitance Tomography System Design

    Directory of Open Access Journals (Sweden)

    Ruzairi ABDUL RAHIM

    2010-03-01

    Full Text Available Electrical capacitance tomography system is a system which can be used for imaging industrial multi-component processes involving non-conducting fluids in pipelines. In order to make an ECT system applicable in all kinds of industries, the cost factor of building an ECT system is essential. In this research, we focus on reducing the cost of the system while not affecting the quality of the results. In the past, most of the researches in tomography system have concentrated more on the design of the sensor, and use DAS card as the interface to the PC. This will increase the cost of the system. In this case, the cost of the data acquisition system will be needed to be taken into consideration. To develop a low cost and fast data acquisition system, a Universal Serial Bus (USB is found to be the most ideal technology. In order to further reduce the cost of the ECT system, a very low cost material, aluminium plates are used as the electrodes of the system. The information obtained in the PC will be reconstructed using iterative algorithm in order to obtain a precise image of the flow in the pipeline. The information obtained from the system will be useful for the purpose of controlling the flow in the pipeline.

  3. The Cost-Effectiveness and Return-On-Investment of a Combined Social and Physical Environmental Intervention in Office Employees

    Science.gov (United States)

    van Dongen, J. M.; Coffeng, J. K.; van Wier, M. F.; Boot, C. R. L.; Hendriksen, I. J. M.; van Mechelen, W.; Bongers, P. M.; van der Beek, A. J.; Bosmans, J. E.; van Tulder, M. W.

    2017-01-01

    This study explored the cost-effectiveness and return-on-investment of a combined social and physical environmental worksite health promotion program compared with usual practice, and of both intervention conditions separately. Participants were randomized to the combined intervention (n = 92), social environmental intervention (n = 118), physical…

  4. Effects of housing system on the costs of commercial egg production1

    Science.gov (United States)

    Matthews, W. A.; Sumner, D. A.

    2014-01-01

    This article reports the first publicly available egg production costs compared across 3 hen-housing systems. We collected detailed data from 2 flock cycles from a commercial egg farm operating a conventional barn, an aviary, and an enriched colony system at the same location. The farm employed the same operational and accounting procedures for each housing system. Results provide clear evidence that egg production costs are much higher for the aviary system than the other 2 housing systems. Feed costs per dozen eggs are somewhat higher for the aviary and lower for the enriched house compared with the conventional house. Labor costs are much lower for the conventional house than the other 2, and pullet costs are much higher for the aviary. Energy and miscellaneous costs are a minimal part of total operating costs and do not differ by housing system. Total capital investments per hen-capacity are much higher for the aviary and the enriched house. Capital costs per dozen eggs depend on assumptions about appropriate interest and depreciation rates. Using the same 10% rate for each housing system shows capital costs per dozen for the aviary and the enriched housing system are much higher than capital costs per dozen for the conventional house. The aviary has average operating costs (feed, labor, pullet, energy, and miscellaneous costs that recur for each flock and vary with egg production) about 23% higher and average total costs about 36% higher compared with the conventional house. The enriched housing system has average operating costs only about 4% higher compared with the conventional house, but average total costs are 13% higher than for the conventional house. PMID:25480736

  5. Heat pumps in combined heat and power systems

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Wiebke Brix; Elmegaard, Brian

    2014-01-01

    Heat pumps have previously been proposed as a way to integrate higher amounts of renewable energy in DH (district heating) networks by integrating, e.g., wind power. The paper identifies and compares five generic configurations of heat pumps in DH systems. The operational performance...... of the considered cases. When considering a case where the heat pump is located at a CHP (combined heat and power) plant, a configuration that increases the DH return temperature proposes the lowest operation cost, as low as 12 EUR MWh-1 for a 90 °C e 40 °C DH network. Considering the volumetric heating capacity......, a third configuration is superior in all cases. Finally, the three most promising heat pump configurations are integrated in a modified PQ-diagram of the CHP plant. Each show individual advantages, and for two, also disadvantages in order to achieve flexible operation....

  6. Modelling and exergoeconomic-environmental analysis of combined cycle power generation system using flameless burner for steam generation

    International Nuclear Information System (INIS)

    Hosseini, Seyed Ehsan; Barzegaravval, Hasan; Ganjehkaviri, Abdolsaeid; Wahid, Mazlan Abdul; Mohd Jaafar, M.N.

    2017-01-01

    Highlights: • Using flameless burner as a supplementary firing system after gas turbine is modeled. • Thermodynamic, economic and environmental analyses of this model are performed. • Efficiency of the plant increases about 6% and CO_2 emission decreases up to 5.63% in this design. • Available exergy for work production in both gas cycle and steam cycle increases in this model. - Abstract: To have an optimum condition for the performance of a combined cycle power generation, using supplementary firing system after gas turbine was investigated by various researchers. Since the temperature of turbine exhaust is higher than auto-ignition temperature of the fuel in optimum condition, using flameless burner is modelled in this paper. Flameless burner is installed between gas turbine cycle and Rankine cycle of a combined cycle power plant which one end is connected to the outlet of gas turbine (as primary combustion oxidizer) and the other end opened to the heat recovery steam generator. Then, the exergoeconomic-environmental analysis of the proposed model is evaluated. Results demonstrate that efficiency of the combined cycle power plant increases about 6% and CO_2 emission reduces up to 5.63% in this proposed model. It is found that the variation in the cost is less than 1% due to the fact that a cost constraint is implemented to be equal or lower than the design point cost. Moreover, exergy of flow gases increases in all points except in heat recovery steam generator. Hence, available exergy for work production in both gas cycle and steam cycle will increase in new model.

  7. Marginal cost calculation of energy production in hydro thermoelectric systems considering the transmission system

    International Nuclear Information System (INIS)

    Pereira, M.V.F.; Gorenstin, B.G.; Alvarenga Filho, S.

    1989-01-01

    The alternatives for calculation of energy marginal cost in hydroelectric systems, considering the transmission one, was analysed, including fundamental concepts; generation/transmission systems, represented by linear power flow model; production marginal costs in hydrothermal systems and computation aspects. (C.G.C.). 11 refs, 5 figs

  8. Logistics Cost Calculation of Implementation Warehouse Management System: A Case Study

    Directory of Open Access Journals (Sweden)

    Kučera Tomáš

    2017-01-01

    Full Text Available Warehouse management system can take full advantage of the resources and provide efficient warehousing services. The paper aims to show advantages and disadvantages of the warehouse management system in a chosen enterprise, which is focused on logistics services and transportation. The paper can bring new innovative approach for warehousing and presents how logistics enterprise can reduce logistics costs. This approach includes cost reduction of the establishment, operation and savings in the overall assessment of the implementation of the warehouse management system. The innovative warehouse management system will be demonstrated as the case study, which is classified as a qualitative scientific method, in the chosen logistics enterprise. The paper is based on the research of the world literature, analyses of the internal logistics processes, data and finally enterprise documents. The paper discovers costs related to personnel costs, handling equipment costs and costs for material identification. Implementation of the warehouse management system will reduce overall logistics costs of warehousing and extend the warehouse management system to other parts of the logistics chain.

  9. Cost analysis of energy storage systems for electric utility applications

    Energy Technology Data Exchange (ETDEWEB)

    Akhil, A. [Sandia National Lab., Albuquerque, NM (United States); Swaminathan, S.; Sen, R.K. [R.K. Sen & Associates, Inc., Bethesda, MD (United States)

    1997-02-01

    Under the sponsorship of the Department of Energy, Office of Utility Technologies, the Energy Storage System Analysis and Development Department at Sandia National Laboratories (SNL) conducted a cost analysis of energy storage systems for electric utility applications. The scope of the study included the analysis of costs for existing and planned battery, SMES, and flywheel energy storage systems. The analysis also identified the potential for cost reduction of key components.

  10. Cost-effectiveness of early initiation of first-line combination antiretroviral therapy in Uganda

    Directory of Open Access Journals (Sweden)

    Sempa Joseph

    2012-09-01

    Full Text Available Abstract Background Ugandan national guidelines recommend initiation of combination antiretroviral therapy (cART at CD4+ T cell (CD4 count below 350 cell/μl, but the implementation of this is limited due to availability of medication. However, cART initiation at higher CD4 count increases survival, albeit at higher lifetime treatment cost. This analysis evaluates the cost-effectiveness of initiating cART at a CD4 count between 250–350 cell/μl (early versus Methods Life expectancy of cART-treated patients, conditional on baseline CD4 count, was modeled based on published literature. First-line cART costs $192 annually, with an additional $113 for patient monitoring. Delaying initiation of cART until the CD4 count falls below 250 cells/μl would incur the cost of the bi-annual CD4 count tests and routine maintenance care at $85 annually. We compared lifetime treatment costs and disability adjusted life-expectancy between early vs. delayed cART for ten baseline CD4 count ranges from 250-350 cell/μl. All costs and benefits were discounted at 3% annually. Results Treatment delay varied from 6–18 months. Early cART initiation increased life expectancy from 1.5-3.5 years and averted 1.33–3.10 disability adjusted life years (DALY’s per patient. Lifetime treatment costs were $4,300–$5,248 for early initiation and $3,940–$4,435 for delayed initiation. The cost/DALY averted of the early versus delayed start ranged from $260–$270. Conclusions In HIV-positive patients presenting with CD4 count between 250-350 cells/μl, immediate initiation of cART is a highly cost-effective strategy using the recommended one-time per capita GDP threshold of $490 reported for Uganda. This would constitute an efficient use of scarce health care funds.

  11. 18 CFR 301.7 - Average System Cost methodology functionalization.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Average System Cost... REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS FOR FEDERAL POWER MARKETING ADMINISTRATIONS AVERAGE SYSTEM COST METHODOLOGY FOR SALES FROM UTILITIES TO BONNEVILLE POWER ADMINISTRATION UNDER NORTHWEST POWER...

  12. Tetra-combined cogeneration system. Exergy and thermoeconomic evaluation; Sistema tetra combinado de cogeracao. Avaliacao exergetica e termoeconomica

    Energy Technology Data Exchange (ETDEWEB)

    Arriola, Domingo Wilson Garagatti [Sao Paulo Univ., SP (Brazil). Escola Politecnica. Dept. de Engenharia Mecanica]. E-mail: wgarriol@usp.br; Oliveira Junior, Silvio de [Instituto de Pesquisas Tecnologicas (IPT), Sao Paulo, SP (Brazil)]. E-mail: olivsilj@ipt.br

    2000-07-01

    The description and the exergy and thermo economic evaluation of a new cogeneration system, called tetra-combined cogeneration system, that generates electricity and chilled water (for air conditioning purposes) and eventually steam is presented. This system is composed of a gas turbine, a heat recovery steam generator, a condensation/extraction steam turbine and a hybrid absorption/steam ejection chiller.The exergy and thermo economic performance (exergy based costs of electricity, steam and chilled water production) of this system is compared with the performances of conventional cogeneration systems, pointing out the advantages and disadvantages of this new system. (author)

  13. Factors Associated with Photovoltaic System Costs (Topical Issues Brief)

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, J.

    2001-06-12

    A variety of factors can affect the cost of photovoltaic systems. This report analyses the relationship among such factors by using information entered into a voluntary registry of PV systems and performing regression analyses. The results showed statistically significant relationships between photovoltaic system cost and (a) grid connection, (b) installation year, (c) areas where the utility had entered into volume purchasing agreements.

  14. A combined system for measuring animal motion activities.

    Science.gov (United States)

    Young, M S; Young, C W; Li, Y C

    2000-01-31

    In this study, we have developed a combined animal motion activity measurement system that combines an infrared light matrix subsystem with an ultrasonic phase shift subsystem for animal activity measurement. Accordingly, in conjunction with an IBM PC/AT compatible personal computer, the combined system has the advantages of both infrared and ultrasonic subsystems. That is, it can at once measure and directly analyze detailed changes in animal activity ranging from locomotion to tremor. The main advantages of this combined system are that it features real time data acquisition with the option of animated real time or recorded display/playback of the animal's motion. Additionally, under the multi-task operating condition of IBM PC, it can acquire and process behavior using both IR and ultrasound systems simultaneously. Traditional systems have had to make separate runs for gross and fine movement recording. This combined system can be profitably employed for normative behavioral activity studies and for neurological and pharmacological research.

  15. Potential Cost Savings for Use of 3D Printing Combined With 3D Imaging and CPLM for Fleet Maintenance and Revitalization

    Science.gov (United States)

    2014-04-30

    bäÉîÉåíÜ=^ååì~ä=^Åèìáëáíáçå= oÉëÉ~êÅÜ=póãéçëáìã= qÜìêëÇ~ó=pÉëëáçåë= sçäìãÉ=ff= = Potential Cost Savings for Use of 3D Printing Combined With 3D...TYPE 3. DATES COVERED 00-00-2014 to 00-00-2014 4. TITLE AND SUBTITLE Potential Cost Savings for Use of 3D Printing Combined With 3D Imaging and...Chair: RADM David Lewis, USN Program Executive Officer, SHIPS Potential Cost Savings for Use of 3D Printing Combined With 3D Imaging and CPLM for

  16. Least-cost failure diagnosis in uncertain reliability systems

    International Nuclear Information System (INIS)

    Cox, Louis Anthony; Chiu, Steve Y.; Sun Xiaorong

    1996-01-01

    In many textbook solutions, for systems failure diagnosis problems studied using reliability theory and artificial intelligence, the prior probabilities of different failure states can be estimated and used to guide the sequential search for failed components after the whole system fails. In practice, however, both the component failure probabilities and the structure function of the system being examined--i.e., the mapping between the states of its components and the state of the system--may not be known with certainty. At best:, the probabilities of different hypothesized system descriptions, each specifying the component failure probabilities and the system's structure function, may be known to a useful approximation, perhaps based on sample data and previous experience. Cost-effective diagnosis of the system's failure state is then a challenging problem. Although the probabilities of component failures are aleatory, uncertainties about these probabilities and about the system structure function are epistemic. This paper examines how to make best use of both epistemic prior probabilities for system descriptions and the information gleaned from costly inspections of component states after the system fails, to minimize the average cost of identifying the failure state. Two approaches are introduced for systems dominated by aleatory uncertainties, one motivated by information theory and the other based on the idea of trying to prove a hypothesis about the identity of the failure state as efficiently as possible. While the general problem of cost-effective failure diagnosis is computationally intractable (NP-hard), both heuristics provide useful approximations on small to moderate sized problems and optimal results for certain common types of reliability systems, including series, parallel, parallel-series, and k-out-of-n systems. A hybrid heuristic that adaptively chooses which heuristic to apply next after any sequence of observations (component test results

  17. (Dysfunctionality of accounting cost systems in manufacturing companies of Tuzla canton

    Directory of Open Access Journals (Sweden)

    Sado Puškarević

    2014-12-01

    Full Text Available This paper shows the results of the conducted primary survey on functionality of cost systems in manufacturing companies of Tuzla Canton (hereinafter “TC”. This paper assesses their adequacy to the needs of these companies: the present needs, and the ones that will be brought by the changes in the environment. These systems have to be up-to-date, as they influence the process of cost management, which is the key factor of companies’ adaptation to the conditions of a modern market. Cost management, which is based on the information of a cost system, enables the company to take the adequate stand towards customers on markets and toward their competition. Also, the quality cost information is a precondition for effective and efficient allocation of limited resources in a transitional period of society development. Therefore, only quality designed cost system in transitional economy will enable recovery, and then, growth and development of a company. This emphasizes the importance of research of the stated issues for transitional countries. The research results should also help to persuade the management about the need to modernize the operation organization, primarily the accounting function, mainly in the part of cost system organization. The determined defects, as well as deviances in relation to current needs for information about costs, are guidelines for an adequate process of redesigning cost systems in companies of transitional economy.

  18. Technical note: Test of a low-cost and animal-friendly system for measuring methane emissions from dairy cows

    DEFF Research Database (Denmark)

    Hellwing, Anne Louise Frydendahl; Lund, Peter; Weisbjerg, Martin Riis

    2012-01-01

    the animals in chambers, as dry matter intake before and during chamber stay were similar. It was concluded that the system delivers reliable values, and the transparent construction in combination with the location in the barn environment prevent negative impact on animal welfare and, thereby, data quality.......Methane is a greenhouse gas with a significant anthropogenic contribution from cattle production. A demand exists for techniques that facilitate evaluation of mitigation strategies for dairy cows. Therefore, a low-cost system facilitating the highest possible animal welfare was constructed...... and validated. The system uses the same principles as systems for open-circuit indirect calorimetry, but to lower the costs, the chamber construction and air-conditioning system were simpler than described for other open-circuit systems. To secure the highest possible animal welfare, the system is located...

  19. Comparison of algae cultivation methods for bioenergy production using a combined life cycle assessment and life cycle costing approach.

    Science.gov (United States)

    Resurreccion, Eleazer P; Colosi, Lisa M; White, Mark A; Clarens, Andres F

    2012-12-01

    Algae are an attractive energy source, but important questions still exist about the sustainability of this technology on a large scale. Two particularly important questions concern the method of cultivation and the type of algae to be used. This present study combines elements of life cycle analysis (LCA) and life cycle costing (LCC) to evaluate open pond (OP) systems and horizontal tubular photobioreactors (PBRs) for the cultivation of freshwater (FW) or brackish-to-saline water (BSW) algae. Based on the LCA, OPs have lower energy consumption and greenhouse gas emissions than PBRs; e.g., 32% less energy use for construction and operation. According to the LCC, all four systems are currently financially unattractive investments, though OPs are less so than PBRs. BSW species deliver better energy and GHG performance and higher profitability than FW species in both OPs and PBRs. Sensitivity analyses suggest that improvements in critical cultivation parameters (e.g., CO(2) utilization efficiency or algae lipid content), conversion parameters (e.g., anaerobic digestion efficiency), and market factors (e.g., costs of CO(2) and electricity, or sale prices for algae biodiesel) could alter these results. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Fuzzy adaptive integration scheme for low-cost SINS/GPS navigation system

    Science.gov (United States)

    Nourmohammadi, Hossein; Keighobadi, Jafar

    2018-01-01

    Due to weak stand-alone accuracy as well as poor run-to-run stability of micro-electro mechanical system (MEMS)-based inertial sensors, special approaches are required to integrate low-cost strap-down inertial navigation system (SINS) with global positioning system (GPS), particularly in long-term applications. This paper aims to enhance long-term performance of conventional SINS/GPS navigation systems using a fuzzy adaptive integration scheme. The main concept behind the proposed adaptive integration is the good performance of attitude-heading reference system (AHRS) in low-accelerated motions and its degradation in maneuvered or accelerated motions. Depending on vehicle maneuvers, gravity-based attitude angles can be intelligently utilized to improve orientation estimation in the SINS. Knowledge-based fuzzy inference system is developed for decision-making between the AHRS and the SINS according to vehicle maneuvering conditions. Inertial measurements are the main input data of the fuzzy system to determine the maneuvering level during the vehicle motions. Accordingly, appropriate weighting coefficients are produced to combine the SINS/GPS and the AHRS, efficiently. The assessment of the proposed integrated navigation system is conducted via real data in airborne tests.

  1. A Combined Two-Method MPPT Control Scheme for Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Dorofte, Christinel; Borup, Uffe; Blaabjerg, Frede

    2005-01-01

    In order to increase the output efficiency of a grid-connected photovoltaic (PV) system it is important to have an efficient Maximum Power Point Tracker (MPPT). In the case of low irradiation, the Perturb and Observe (PO) and Incremental Conductance (IC) methods have a poor efficiency, because...... of the poor resolution in the acquired signals, when a fixed point implementation is done. A cost-effective two-method MPPT control scheme is proposed in this paper to track the maximum power point (MPP) at both low and high irradiation, by combining a Constant Voltage (CV) method and modified PO algorithm...

  2. Grid-connected photovoltaic systems for Malaysian residential sector: Effects of component costs, feed-in tariffs, and carbon taxes

    International Nuclear Information System (INIS)

    Lau, K.Y.; Muhamad, N.A.; Arief, Y.Z.; Tan, C.W.; Yatim, A.H.M.

    2016-01-01

    Blessed with abundant solar radiation, Malaysia has a huge potential for grid-connected PV (photovoltaic) installations, particularly for its fast-growing residential sector. Nevertheless, Malaysia's PV installation capacity is relatively small compared with the global PV capacity. Significantly, the pricing mechanisms for grid-connected PV projects need to be appropriately assessed to build up the public's confidence to invest in PV projects. In this paper, we analyze the effects of component costs, FiTs (feed-in tariffs), and carbon taxes on grid-connected PV systems in Malaysian residential sector using the HOMER (Hybrid Optimization of Multiple Energy Resources) software. Results demonstrate that the implementation of grid-connected PV systems is highly feasible with PV array costs of $ 1120/kW or lower. For higher PV array costs up to $ 2320/kW, introducing an FiT rate three times higher ($ 0.30/kWh) than the grid tariff for a 100 kW grid sale capacity will, NPC-wise, prioritize grid-connected PV systems over the utility grid. By implementing the FiT ($ 0.50/kWh) and the carbon tax ($ 36/metric ton) schemes simultaneously, grid-connected PV systems will remain as the optimal systems even for costly PV arrays (up to $ 4000/kW). The findings are of paramount importance as far as PV pricing variability is concerned. - Highlights: • Grid-connected PV for Malaysian residential sector has been analyzed using HOMER. • Component costs, feed-in tariffs, and carbon taxes affect optimal system types. • Grid-connected PV projects are feasible for low PV array costs ($ 1120/kW or lower). • For higher PV array and inverter costs, feed-in tariffs should be implemented. • Combining feed-in tariffs with carbon taxes are effective for further lowering NPCs.

  3. A comprehensive economic evaluation of integrated desalination systems using fossil fuelled and nuclear energies and including their environmental costs

    International Nuclear Information System (INIS)

    Nisan, S.; Benzarti, N.

    2008-01-01

    Seawater desalination is now widely accepted as an attractive alternative source of freshwater for domestic and industrial uses. Despite the considerable progress made in the relevant technologies desalination, however, remains an energy intensive process in which the energy cost is the paramount factor. This Study is a first of a kind in that we have integrated the environmental costs into the power and desalination costs. The study has focused on the seawater desalination cost evaluation of the following systems. It is supposed that they will be operating in the co-generation mode (Simultaneous production of electrical power and desalted water) in 2015: Fossil fuelled based systems such as the coal and oil fired plants and the gas turbine combined cycle plant, coupled to MED, and RO; Pressurised water reactors such as the PWR-900 and the AP-600, coupled to MED, and RO; High temperature reactors such as the GT-MHR, the PBMR, coupled to MED, with the utilisation of virtually free waste-heat provided by these reactors. The study is made in real site-specific conditions of a site In Southern Europe. Sensitivity studies for different parameters such as the fossil fuel prices, interest and discount rates, power costs etc., have also been undertaken. The results obtained are then used to evaluate the financial interest of selected integrated desalination systems in terms of a detailed cash flow analysis, providing the net present values, pay back periods and the internal rate of returns. Analysis of the results shows that among the fossil fuelled systems the power and desalination costs by circulating fluidized bed coal fired plant would be the lowest with current coal prices. Those by oil fired plants would be highest. In all cases, integrated nuclear energy systems would lead to considerably lower power and water costs than the corresponding coal based systems. When external costs for different energies are internalized in power and water costs, the relative cost

  4. A “Cookbook” Cost Analysis Procedure for Medical Information Systems*

    Science.gov (United States)

    Torrance, Janice L.; Torrance, George W.; Covvey, H. Dominic

    1983-01-01

    A costing procedure for medical information systems is described. The procedure incorporates state-of-the-art costing methods in an easy to follow “cookbook” format. Application of the procedure consists of filling out a series of Mac-Tor EZ-Cost forms. The procedure and forms have been field tested by application to a cardiovascular database system. This article describes the major features of the costing procedure. The forms and other details are available upon request.

  5. Assessment of Environmental and Economic Impacts of Vine-Growing Combining Life Cycle Assessment, Life Cycle Costing and Multicriterial Analysis

    Directory of Open Access Journals (Sweden)

    Giacomo Falcone

    2016-08-01

    Full Text Available The wine sector is going through a significant evolution dealing with the challenges of competition issues in international markets and with necessary commitments to sustainability improvement. In the wine supply chain, the agricultural phase represents a potential source of pollution and costs. From the farmers’ point of view, these contexts require them to be more attentive and find a compromise among environmental benefits, economic benefits, and costs linked to farming practices. This paper aims to make a sustainability assessment of different wine-growing scenarios located in Calabria (Southern Italy that combines conflicting insights, i.e., environmental and economic ones, by applying Life Cycle Assessment (LCA and Life Cycle Costing (LCC to identify the main hotspots and select the alternative scenarios closest to the ideal solution through the VIKOR multicriteria method. In particular, the latter allowed us to obtain synthetic indices for a two-dimensional sustainability assessment. Conventional practices associated to the espalier training system represent the best compromise from both environmental and economic points of view, due to the higher yield per hectare. The choices regarding Functional Unit (FU and indicators were shown to have a high influence on results.

  6. A framework for assessing cost management system changes: the case of activity-based costing implementation at food industry

    Directory of Open Access Journals (Sweden)

    Tayebeh Faraji

    2015-04-01

    Full Text Available An opportunity to investigate the technical and organizational effect of management accounting system changes has appeared with companies' adoption of activity-based costing (ABC. This paper presents an empirical investigation to study the effects of ABC system for case study from food industry in Iran. From this case, the paper develops a framework for assessing ABC implementation and hypotheses about factors that influence implementation. The study detects five cost centers and for each cost center, it determines different cost drivers. The results of our survey has detected that implementation of ABC system not only helps precise allocation of overhead costs but also helps internal management companies for better planning and control of production, making better decisions for company's profits.

  7. Base-Load and Peak Electricity from a Combined Nuclear Heat and Fossil Combined-Cycle Plant

    International Nuclear Information System (INIS)

    Conklin, Jim; Forsberg, Charles W.

    2007-01-01

    A combined-cycle power plant is proposed that uses heat from a high-temperature reactor and fossil fuel to meet base-load and peak electrical demands. The high-temperature gas turbine produces shaft power to turn an electric generator. The hot exhaust is then fed to a heat recovery steam generator (HRSG) that provides steam to a steam turbine for added electrical power production. A simplified computational model of the thermal power conversion system was developed in order to parametrically investigate two different steady-state operation conditions: base load nuclear heat only from an Advanced High Temperature Reactor (AHTR), and combined nuclear heat with fossil heat to increase the turbine inlet temperature. These two cases bracket the expected range of power levels, where any intermediate power level can result during electrical load following. The computed results indicate that combined nuclear-fossil systems have the potential to offer both low-cost base-load electricity and lower-cost peak power relative to the existing combination of base-load nuclear plants and separate fossil-fired peak-electricity production units. In addition, electric grid stability, reduced greenhouse gases, and operational flexibility can also result with using the conventional technology presented here for the thermal power conversion system coupled with the AHTR

  8. Survey on the cost of the photovoltaic power system; Taiyoko hatsuden cost chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    Comparisons were made of the power generation cost in Indonesia and Thailand between the photovoltaic power system and other power systems. From the difference in technical standards with Japan, trially calculated were the amount of the potential introduction and the possibly reduced cost. In Indonesia, a plan has started for the introduction of a 50W system to 1 million houses in the unelecrified area, but the introduction has not been so promoted as planned. In Thailand, a plan is being carried out for the introduction of the battery charge station system, but the introduction has remained small-scaled. Comparisons were made among the solar home system in Indonesia, the battery charge station system in Thailand, the diesel engine power generation, and the grid connection with the existing power distribution system. The result concluded that the solar home system is low-priced though it depends on the distance from the existing distribution line and the power consumption amount. Moreover, it was found that the system would be more economical than in the case of Japan if obeying international standards for the photovoltaic power system. 6 refs., 15 figs., 56 tabs.

  9. On-farm welfare assessment systems: what are the recording costs?

    DEFF Research Database (Denmark)

    Sørensen, Jan Tind; Nielsen, Tine Rousing; Møller, Steen Henrik

    2007-01-01

    To illustrate that different approaches lead to different costs a cost calculation on four different welfare assessment systems for four different animal species has been carried out; an integrated pig herd (450 sows), a dairy cattle herd with automatic milking (90 cows), an organic egg production...... system (3000 layers) and a mink farm (1000 mink). We calculated the cost to be: E 375 per annum for the mink farm and E 2205, E 2430 and E 2435 for the egg production system, the AMS dairy herd and the integrated pig farm, respectively. The costs can be reduced by: reducing the number of indicators and...

  10. Exergy-based method for analyzing the composition of the electricity cost generated in gas-fired combined cycle plants

    Energy Technology Data Exchange (ETDEWEB)

    Sarraf Borelli, Samuel Jose [Promon Engenharia Ltda., Av. Presidente Juscelino Kubitschek, 1830, Itaim, CEP:04543-900 Sao Paulo/SP (Brazil)], E-mail: sborelli@terra.com.br; Oliveira Junior, Silvio de [Environmental and Thermal Engineering Laboratory, Polytechnic School, University of Sao Paulo, Av. Prof. Luciano Gualberto, 1289, Cidade Universitaria, CEP:05508-900 Sao Paulo/SP (Brazil)], E-mail: silvio.oliveira@poli.usp.br

    2008-02-15

    The proposed method to analyze the composition of the cost of electricity is based on the energy conversion processes and the destruction of the exergy through the several thermodynamic processes that comprise a combined cycle power plant. The method uses thermoeconomics to evaluate and allocate the cost of exergy throughout the processes, considering costs related to inputs and investment in equipment. Although the concept may be applied to any combined cycle or cogeneration plant, this work develops only the mathematical modeling for three-pressure heat recovery steam generator (HRSG) configurations and total condensation of the produced steam. It is possible to study any nx1 plant configuration (n sets of gas turbine and HRSGs associated to one steam turbine generator and condenser) with the developed model, assuming that every train operates identically and in steady state. The presented model was conceived from a complex configuration of a real power plant, over which variations may be applied in order to adapt it to a defined configuration under study [Borelli SJS. Method for the analysis of the composition of electricity costs in combined cycle thermoelectric power plants. Master in Energy Dissertation, Interdisciplinary Program of Energy, Institute of Eletro-technical and Energy, University of Sao Paulo, Sao Paulo, Brazil, 2005 (in Portuguese)]. The variations and adaptations include, for instance, use of reheat, supplementary firing and partial load operation. It is also possible to undertake sensitivity analysis on geometrical equipment parameters.

  11. Exergy-based method for analyzing the composition of the electricity cost generated in gas-fired combined cycle plants

    Energy Technology Data Exchange (ETDEWEB)

    Borelli, Samuel Jose Sarraf [Promon Engenharia Ltda., Av. Presidente Juscelino Kubitschek, 1830, Itaim, CEP:04543-900 Sao Paulo/SP (Brazil); De Oliveira Junior, Silvio [Environmental and Thermal Engineering Laboratory, Polytechnic School, University of Sao Paulo, Av. Prof. Luciano Gualberto, 1289, Cidade Universitaria, CEP:05508-900 Sao Paulo/SP (Brazil)

    2008-02-15

    The proposed method to analyze the composition of the cost of electricity is based on the energy conversion processes and the destruction of the exergy through the several thermodynamic processes that comprise a combined cycle power plant. The method uses thermoeconomics to evaluate and allocate the cost of exergy throughout the processes, considering costs related to inputs and investment in equipment. Although the concept may be applied to any combined cycle or cogeneration plant, this work develops only the mathematical modeling for three-pressure heat recovery steam generator (HRSG) configurations and total condensation of the produced steam. It is possible to study any n x 1 plant configuration (n sets of gas turbine and HRSGs associated to one steam turbine generator and condenser) with the developed model, assuming that every train operates identically and in steady state. The presented model was conceived from a complex configuration of a real power plant, over which variations may be applied in order to adapt it to a defined configuration under study [Borelli SJS. Method for the analysis of the composition of electricity costs in combined cycle thermoelectric power plants. Master in Energy Dissertation, Interdisciplinary Program of Energy, Institute of Eletro-technical and Energy, University of Sao Paulo, Sao Paulo, Brazil, 2005 (in Portuguese)]. The variations and adaptations include, for instance, use of reheat, supplementary firing and partial load operation. It is also possible to undertake sensitivity analysis on geometrical equipment parameters. (author)

  12. Exergy-based method for analyzing the composition of the electricity cost generated in gas-fired combined cycle plants

    International Nuclear Information System (INIS)

    Sarraf Borelli, Samuel Jose; Oliveira Junior, Silvio de

    2008-01-01

    The proposed method to analyze the composition of the cost of electricity is based on the energy conversion processes and the destruction of the exergy through the several thermodynamic processes that comprise a combined cycle power plant. The method uses thermoeconomics to evaluate and allocate the cost of exergy throughout the processes, considering costs related to inputs and investment in equipment. Although the concept may be applied to any combined cycle or cogeneration plant, this work develops only the mathematical modeling for three-pressure heat recovery steam generator (HRSG) configurations and total condensation of the produced steam. It is possible to study any nx1 plant configuration (n sets of gas turbine and HRSGs associated to one steam turbine generator and condenser) with the developed model, assuming that every train operates identically and in steady state. The presented model was conceived from a complex configuration of a real power plant, over which variations may be applied in order to adapt it to a defined configuration under study [Borelli SJS. Method for the analysis of the composition of electricity costs in combined cycle thermoelectric power plants. Master in Energy Dissertation, Interdisciplinary Program of Energy, Institute of Eletro-technical and Energy, University of Sao Paulo, Sao Paulo, Brazil, 2005 (in Portuguese)]. The variations and adaptations include, for instance, use of reheat, supplementary firing and partial load operation. It is also possible to undertake sensitivity analysis on geometrical equipment parameters

  13. Grid Connected Integrated Community Energy System. Volume 3A. Integrated demonstration systems and costs. Final report: Phase I, February 1, 1977-May 31, 1977

    Energy Technology Data Exchange (ETDEWEB)

    1977-06-01

    In 1973, the University of Minnesota set a goal of conversion and retrofit for University Heating Plant whereby coal or lignite would become the primary fuel by the year 1980. The University, with the addition of St. Mary's and Fairview Hospitals, Augsburg College, and possibly some small Community add-ons, provides a community wherein a major portion of steam distribution is already established. This provides for the development of a larger Grid-ICES for relatively low capital expenditures. Steam demand factors, equipment, and costs are discussed. A discussion on the steam production system is followed by a description of the capital costs of demonstration systems (specifically, baghouses). The solid waste heat recovery system, fuel and energy transport and storage, and district heating by steam and hot water are discussed. The combined community service demands are detailed.

  14. Impact of Capital and Current Costs Changes of the Incineration Process of the Medical Waste on System Management Cost

    Science.gov (United States)

    Jolanta Walery, Maria

    2017-12-01

    The article describes optimization studies aimed at analysing the impact of capital and current costs changes of medical waste incineration on the cost of the system management and its structure. The study was conducted on the example of an analysis of the system of medical waste management in the Podlaskie Province, in north-eastern Poland. The scope of operational research carried out under the optimization study was divided into two stages of optimization calculations with assumed technical and economic parameters of the system. In the first stage, the lowest cost of functioning of the analysed system was generated, whereas in the second one the influence of the input parameter of the system, i.e. capital and current costs of medical waste incineration on economic efficiency index (E) and the spatial structure of the system was determined. Optimization studies were conducted for the following cases: with a 25% increase in capital and current costs of incineration process, followed by 50%, 75% and 100% increase. As a result of the calculations, the highest cost of system operation was achieved at the level of 3143.70 PLN/t with the assumption of 100% increase in capital and current costs of incineration process. There was an increase in the economic efficiency index (E) by about 97% in relation to run 1.

  15. Solar desalination system of combined solar still and humidification-dehumidification unit

    Science.gov (United States)

    Ghazy, Ahmed; Fath, Hassan E. S.

    2016-11-01

    Solar stills, as a simple technology, have many advantages such as simple design; unsophisticated fabrication; low capital and operation costs and easily maintained. However, their low daily production has put constraints on their usage. A radical improvement in the performance of solar stills can be achieved by the partial recovery of the energy losses from the glass cover of the still. This paper simulates a direct solar distillation system of combined solar still with an air heating humidification-dehumidification (HDH) sub-system. The main objective of the Still-HDH system is to improve the productivity and thermal efficiency of the conventional solar still by partially recovering the still energy losses to the ambient for additional water production. Various procedures have been employed to improve the thermal performance of the integrated system by recovering heat losses from one component in another component of the system. Simulations have been carried out for the performance of the Still-HDH system under different weather conditions. A comparison has been held between the Still-HDH system and a conventional solar still of the same size and under the same operating conditions.

  16. Impact of a hospitalist system on length of stay and cost for children with common conditions.

    Science.gov (United States)

    Srivastava, Rajendu; Landrigan, Christopher P; Ross-Degnan, Dennis; Soumerai, Stephen B; Homer, Charles J; Goldmann, Donald A; Muret-Wagstaff, Sharon

    2007-08-01

    This study examined mechanisms of efficiency in a managed care hospitalist system on length of stay and total costs for common pediatric conditions. We conducted a retrospective cohort study (October 1993 to July 1998) of patients in a not-for-profit staff model (HMO 1) and a non-staff-model (HMO 2) managed care organization at a freestanding children's hospital. HMO 1 introduced a hospitalist system for patients in October 1996. Patients were included if they had 1 of 3 common diagnoses: asthma, dehydration, or viral illness. Linear regression models examining length-of-stay-specific costs for prehospitalist and posthospitalist systems were built. Distribution of length of stay for each diagnosis before and after the system change in both study groups was calculated. Interrupted time series analysis tested whether changes in the trends of length of stay and total costs occurred after implementation of the hospitalist system by HMO1 (HMO 2 as comparison group) for all 3 diagnoses combined. A total of 1970 patients with 1 of the 3 study conditions were cared for in HMO 1, and 1001 in HMO 2. After the hospitalist system was introduced in HMO 1, length of stay was reduced by 0.23 days (13%) for asthma and 0.19 days (11%) for dehydration; there was no difference for patients with viral illness. The largest relative reduction in length of stay occurred in patients with a shorter length of stay whose hospitalizations were reduced from 2 days to 1 day. This shift resulted in an average cost-per-case reduction of $105.51 (9.3%) for patients with asthma and $86.22 (7.8%) for patients with dehydration. During the same period, length of stay and total cost rose in HMO 2. Introduction of a hospitalist system in one health maintenance organization resulted in earlier discharges and reduced costs for children with asthma and dehydration compared with another one, with the largest reductions occurring in reducing some 2-day hospitalizations to 1 day. These findings suggest that

  17. Application of Wireless Intelligent Control System for HPS Lamps and LEDs Combined Illumination in Road Tunnel

    Science.gov (United States)

    Lai, Jinxing; Qiu, Junling; Chen, Jianxun; Wang, Yaqiong; Fan, Haobo

    2014-01-01

    Because of the particularity of the environment in the tunnel, the rational tunnel illumination system should be developed, so as to optimize the tunnel environment. Considering the high cost of traditional tunnel illumination system with high-pressure sodium (HPS) lamps as well as the effect of a single light source on tunnel entrance, the energy-saving illumination system with HPS lamps and LEDs combined illumination in road tunnel, which could make full use of these two kinds of lamps, was proposed. The wireless intelligent control system based on HPS lamps and LEDs combined illumination and microcontrol unit (MCU) Si1000 wireless communication technology was designed. And the remote monitoring, wireless communication, and PWM dimming module of this system were designed emphatically. Intensity detector and vehicle flow detector can be configured in wireless intelligent control system, which gather the information to the master control unit, and then the information is sent to the monitoring center through the Ethernet. The control strategies are got by the monitoring center according to the calculated results, and the control unit wirelessly sends parameters to lamps, which adjust the luminance of each segment of the tunnel and realize the wireless intelligent control of combined illumination in road tunnel. PMID:25587266

  18. Systems and methods for energy cost optimization in a building system

    Energy Technology Data Exchange (ETDEWEB)

    Turney, Robert D.; Wenzel, Michael J.

    2016-09-06

    Methods and systems to minimize energy cost in response to time-varying energy prices are presented for a variety of different pricing scenarios. A cascaded model predictive control system is disclosed comprising an inner controller and an outer controller. The inner controller controls power use using a derivative of a temperature setpoint and the outer controller controls temperature via a power setpoint or power deferral. An optimization procedure is used to minimize a cost function within a time horizon subject to temperature constraints, equality constraints, and demand charge constraints. Equality constraints are formulated using system model information and system state information whereas demand charge constraints are formulated using system state information and pricing information. A masking procedure is used to invalidate demand charge constraints for inactive pricing periods including peak, partial-peak, off-peak, critical-peak, and real-time.

  19. Development of LLW and VLLW disposal business cost estimation system

    International Nuclear Information System (INIS)

    Koibuchi, Hiroko; Ishiguro, Hideharu; Matsuda, Kenji

    2004-01-01

    In order to undertake the LLW and VLLW disposal business, various examinations are carried out in RANDEC. Since it is important in undertaking this business to secure funds, a disposal cost must be calculated by way of trial. However, at present, there are many unknown factors such as the amount of wastes, a disposal schedule, the location of a disposal site, and so on, and the cost cannot be determined. Meanwhile, the cost depends on complicated relations among these factors. Then, a 'LLW and VLLW disposal business cost estimation system' has been developed to calculate the disposal cost easily. This system can calculate an annual balance of payments by using a construction and operation cost of disposal facilities, considering economic parameters of tax, inflation rate, interest rate and so on. And the system can calculate internal reserves to assign to next-stage upkeep of the disposal facilities after the disposal operation. A model of disposal site was designed based on assumption of some preconditions and a study was carried out to make a trial calculation by using the system. Moreover, it will be required to reduce construction cost by rationalizing the facility and to make flat an annual business spending by examining the business schedule. (author)

  20. Cost-effectiveness analysis of paclitaxel + carboplatin vs. alternative combinations in the treatment of non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Mario Eandi

    2006-06-01

    Full Text Available Non-small cell lung cancer (NSCLC is the most common type of lung cancer and its medical and economical burden represents a serious matter in Europe and Usa, due to its high mortality rates and drug costs. Lung cancer is responsible for about 30% of cancer death in men and women; in Europe only about 8 per cent of people with lung cancer survive for 5 years. At present combination chemotherapy based on cisplatin or carboplatin associated with paclitaxel, vinorelbine or gemcitabine is the state of the art for the treatment in patients with stage IIIb or IV NSCLC. Aim of this study was to compare the cost-effectiveness of paclitaxel/carboplatin (PCb, gemcitabine/cisplatin (GC and vinorelbine/cisplatin (VC in the perspective of the Italian National Health Service. Therefore we perfomed a semi-Markov decision model mainly based on clinical results from the Italian Lung Cancer Project. The model included differential direct medical costs registered for two years from starting chemotherapy, using tariffs valid for 2005. Benefits was measured by years of life saved (YOLs. The model also allowed to estimate only costs accrued over the period of time, performing a cost-minimisation analysis. According to cost-effectiveness analysis, VC is dominated because it’s more costly and less effective than GC. On the contrary, combination chemotherapy with GC is more inexpensive but less effective than paclitaxel/carboplatin (PCb: in this case we compared the incremental cost-effectiveness ratio (ICER with a maximum acceptable willingness-to-pay (WTP value. In the base scenario the ICER of PCb over GC treatment is 52,326 euro/ YOLs, which is definitely lower than the maximum acceptable WTP value. Sensitivity analyses confirmed the robustness of the results from cost-effectiveness analysis in the base scenario.

  1. Combining Time-Driven Activity-Based Costing with Clinical Outcome in Cost-Effectiveness Analysis to Measure Value in Treatment of Depression.

    Directory of Open Access Journals (Sweden)

    Samir El Alaoui

    both 2013 and 2014; an additional 35% and 33% were in partial remission during 2013 and 2014, respectively. Confidence ellipses occupied the south-east (SE and south-west (SW quadrants of the incremental cost-effectiveness plane at both post-treatment and at follow-up, indicating that the ICBT treatment was less costly and equally effective after staff reallocation.Treating patients to the target of full remission using psychologists instead of medical specialists for post-treatment assessment is cost-saving and consequently a more valuable use of limited resources. TDABC may be a useful tool for measuring resource costs, identifying quality improvement opportunities and evaluating the consequences of such initiatives. Combining TDABC with clinical outcome measures in CEA is potentially a useful approach in mental healthcare to estimate the value of process improvement initiatives.

  2. Preliminary Tests of a New Low-Cost Photogrammetric System

    Science.gov (United States)

    Santise, M.; Thoeni, K.; Roncella, R.; Sloan, S. W.; Giacomini, A.

    2017-11-01

    This paper presents preliminary tests of a new low-cost photogrammetric system for 4D modelling of large scale areas for civil engineering applications. The system consists of five stand-alone units. Each of the units is composed of a Raspberry Pi 2 Model B (RPi2B) single board computer connected to a PiCamera Module V2 (8 MP) and is powered by a 10 W solar panel. The acquisition of the images is performed automatically using Python scripts and the OpenCV library. Images are recorded at different times during the day and automatically uploaded onto a FTP server from where they can be accessed for processing. Preliminary tests and outcomes of the system are discussed in detail. The focus is on the performance assessment of the low-cost sensor and the quality evaluation of the digital surface models generated by the low-cost photogrammetric systems in the field under real test conditions. Two different test cases were set up in order to calibrate the low-cost photogrammetric system and to assess its performance. First comparisons with a TLS model show a good agreement.

  3. PRELIMINARY TESTS OF A NEW LOW-COST PHOTOGRAMMETRIC SYSTEM

    Directory of Open Access Journals (Sweden)

    M. Santise

    2017-11-01

    Full Text Available This paper presents preliminary tests of a new low-cost photogrammetric system for 4D modelling of large scale areas for civil engineering applications. The system consists of five stand-alone units. Each of the units is composed of a Raspberry Pi 2 Model B (RPi2B single board computer connected to a PiCamera Module V2 (8 MP and is powered by a 10 W solar panel. The acquisition of the images is performed automatically using Python scripts and the OpenCV library. Images are recorded at different times during the day and automatically uploaded onto a FTP server from where they can be accessed for processing. Preliminary tests and outcomes of the system are discussed in detail. The focus is on the performance assessment of the low-cost sensor and the quality evaluation of the digital surface models generated by the low-cost photogrammetric systems in the field under real test conditions. Two different test cases were set up in order to calibrate the low-cost photogrammetric system and to assess its performance. First comparisons with a TLS model show a good agreement.

  4. Costs of mixed low-level waste stabilization options

    International Nuclear Information System (INIS)

    Schwinkendorf, W.E.; Cooley, C.R.

    1998-01-01

    Selection of final waste forms to be used for disposal of DOE's mixed low-level waste (MLLW) depends on the waste form characteristics and total life cycle cost. In this paper the various cost factors associated with production and disposal of the final waste form are discussed and combined to develop life-cycle costs associated with several waste stabilization options. Cost factors used in this paper are based on a series of treatment system studies in which cost and mass balance analyses were performed for several mixed low-level waste treatment systems and various waste stabilization methods including vitrification, grout, phosphate bonded ceramic and polymer. Major cost elements include waste form production, final waste form volume, unit disposal cost, and system availability. Production of grout costs less than the production of a vitrified waste form if each treatment process has equal operating time (availability) each year; however, because of the lower volume of a high temperature slag, certification and handling costs and disposal costs of the final waste form are less. Both the total treatment cost and life cycle costs are higher for a system producing grout than for a system producing high temperature slag, assuming equal system availability. The treatment costs decrease with increasing availability regardless of the waste form produced. If the availability of a system producing grout is sufficiently greater than a system producing slag, then the cost of treatment for the grout system will be less than the cost for the slag system, and the life cycle cost (including disposal) may be less depending on the unit disposal cost. Treatment and disposal costs will determine the return on investment in improved system availability

  5. The impact of using an intravenous workflow management system (IVWMS) on cost and patient safety.

    Science.gov (United States)

    Lin, Alex C; Deng, Yihong; Thaibah, Hilal; Hingl, John; Penm, Jonathan; Ivey, Marianne F; Thomas, Mark

    2018-07-01

    The aim of this study was to determine the financial costs associated with wasted and missing doses before and after the implementation of an intravenous workflow management system (IVWMS) and to quantify the number and the rate of detected intravenous (IV) preparation errors. A retrospective analysis of the sample hospital information system database was conducted using three months of data before and after the implementation of an IVWMS System (DoseEdge ® ) which uses barcode scanning and photographic technologies to track and verify each step of the preparation process. The financial impact associated with wasted and missing >IV doses was determined by combining drug acquisition, labor, accessory, and disposal costs. The intercepted error reports and pharmacist detected error reports were drawn from the IVWMS to quantify the number of errors by defined error categories. The total number of IV doses prepared before and after the implementation of the IVWMS system were 110,963 and 101,765 doses, respectively. The adoption of the IVWMS significantly reduced the amount of wasted and missing IV doses by 14,176 and 2268 doses, respectively (p system was $144,019 over 3 months. The total number of errors detected was 1160 (1.14%) after using the IVWMS. The implementation of the IVWMS facilitated workflow changes that led to a positive impact on cost and patient safety. The implementation of the IVWMS increased patient safety by enforcing standard operating procedures and bar code verifications. Published by Elsevier B.V.

  6. Distribution costs -- the cost of local delivery

    International Nuclear Information System (INIS)

    Winger, N.; Zarnett, P.; Carr, J.

    2000-01-01

    Most of the power transmission system in the province of Ontario is owned and operated as a regulated monopoly by Ontario Hydro Services Company (OHSC). Local distribution systems deliver to end-users from bulk supply points within a service territory. OHSC distributes to approximately one million, mostly rural customers, while the approximately 250 municipal utilities together serve about two million, mostly urban customers. Under the Energy Competition Act of 1998 local distribution companies will face some new challenges, including unbundled billing systems, a broader range of distribution costs, increased costs, made up of corporate taxes or payments in lieu of taxes and added costs for regulatory affairs. The consultants provide a detailed discussion of the components of distribution costs, the three components of the typical budget process (capital expenditures, (CAPEX), operating and maintenance (O and M) and administration and corporate (GA and C), a summary of some typical distribution costs in Ontario, and the estimated impacts of the Energy Competition Act (ECA) compliance on charges and rates. Various mitigation strategies are also reviewed. Among these are joint ventures by local distribution companies to reduce ECA compliance costs, re-examination of controllable costs, temporary reduction of the allowable return on equity (ROE) by 50 per cent, and/or reducing the competitive transition charge (CTC). It is estimated that either one of these two reductions could eliminate the full amount of the five to seven per cent uplift in delivered energy service costs. The conclusion of the consultants is that local distribution delivery charges will make up a greater proportion of end-user cost in the future than it has in the past. An increase to customers of about five per cent is expected when the competitive electricity market opens and unbundled billing begins. The cost increase could be mitigated by a combination of actions that would be needed for about

  7. Cost minimization of generation, storage, and new loads, comparing costs with and without externalities

    International Nuclear Information System (INIS)

    Noel, Lance; Brodie, Joseph F.; Kempton, Willett; Archer, Cristina L.; Budischak, Cory

    2017-01-01

    Highlights: • The study models a large regional transmission organization, with various amounts of renewable energy. • The cost of 86 million iterations of energy systems is calculated, with and without externalities. • When including externalities, society should implement 50% renewable energy. - Abstract: The goal of this research is to understand the economics of anticipated large-scale changes in the electric system. 86 million different combinations of renewable generation (wind and solar), natural gas, and three storage types (hydrogen storage, electric vehicles equipped with vehicle-to-grid (V2G) technology, and building heat) are modeled within the PJM Interconnection. The corresponding electric systems are then operated and constrained to meet the load every hour over four years. The total cost of each energy system is calculated, both with and without externalities, to find the least cost energy systems. Using today’s costs of conventional and renewable electricity and without adding any externalities, the cost-minimum system includes no renewable generation, but does include EVs. When externalities are included, however, the most cost-effective to system covers 50% of the electric load with renewable energy and runs reliably without need for either new conventional generation or purpose-built storage. The three novel energy policy implications of this research are: (1) using today’s cost of renewable electricity and estimates of externalities, it is cost effective to implement 240 GW of renewable electricity to meet 50% of the total electric load; (2) there is limited need to construct new natural gas power plants, especially from a system-wide perspective; and (3) existing coal plants may still be useful to the energy system, and instead of being retired, should be repurposed to occasionally provide generation.

  8. Final Report - Stationary and Emerging Market Fuel Cell System Cost Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Contini, Vince [Battelle Memorial Inst., Columbus, OH (United States); Heinrichs, Mike [Battelle Memorial Inst., Columbus, OH (United States); George, Paul [Battelle Memorial Inst., Columbus, OH (United States); Eubanks, Fritz [Battelle Memorial Inst., Columbus, OH (United States); Jansen, Mike [Battelle Memorial Inst., Columbus, OH (United States); Valluri, Manoj [Battelle Memorial Inst., Columbus, OH (United States); Mansouri, Mahan [Battelle Memorial Inst., Columbus, OH (United States); Swickrath, Mike [Battelle Memorial Inst., Columbus, OH (United States)

    2017-04-30

    The U.S. Department of Energy (DOE) is focused on providing a portfolio of technology solutions to meet energy security challenges of the future. Fuel cells are a part of this portfolio of technology offerings. To help meet these challenges and supplement the understanding of the current research, Battelle has executed a five-year program that evaluated the total system costs and total ownership costs of two technologies: (1) an ~80 °C polymer electrolyte membrane fuel cell (PEMFC) technology and (2) a solid oxide fuel cell (SOFC) technology, operating with hydrogen or reformate for different applications. Previous research conducted by Battelle, and more recently by other research institutes, suggests that fuel cells can offer customers significant fuel and emission savings along with other benefits compared to incumbent alternatives. For this project, Battelle has applied a proven cost assessment approach to assist the DOE Fuel Cell Technologies Program in making decisions regarding research and development, scale-up, and deployment of fuel cell technology. The cost studies and subsequent reports provide accurate projections of current system costs and the cost impact of state-of-the-art technologies in manufacturing, increases in production volume, and changes to system design on system cost and life cycle cost for several near-term and emerging fuel cell markets. The studies also provide information on types of manufacturing processes that must be developed to commercialize fuel cells and also provide insights into the optimization needed for use of off-the-shelf components in fuel cell systems. Battelle’s analysis is intended to help DOE prioritize investments in research and development of components to reduce the costs of fuel cell systems while considering systems optimization.

  9. Systemic cost-effectiveness analysis of food hazard reduction

    DEFF Research Database (Denmark)

    Jensen, Jørgen Dejgård; Lawson, Lartey Godwin; Lund, Mogens

    2015-01-01

    stage are considered. Cost analyses are conducted for different risk reduction targets and for three alternative scenarios concerning the acceptable range of interventions. Results demonstrate that using a system-wide policy approach to risk reduction can be more cost-effective than a policy focusing...

  10. A project management quality cost information system for the construction industry

    OpenAIRE

    Love, PED; Irani, Z

    2003-01-01

    A prototype Project Management Quality Cost System (PROMQACS) was developed to determine quality costs in construction projects. The structure and information requirements that are needed to provide a classification system of quality costs were identified and discussed. The developed system was tested and implemented in two case study construction projects to determine the information and management issues needed to develop PROMQACS into a software program. In addition, the system was used to...

  11. Techno-economic analysis of using corn stover to supply heat and power to a corn ethanol plant - Part 2: Cost of heat and power generation systems

    International Nuclear Information System (INIS)

    Mani, S.; Sokhansanj, S.; Tagore, S.; Turhollow, A.F.

    2010-01-01

    This paper presents a techno-economic analysis of corn stover fired process heating (PH) and the combined heat and power (CHP) generation systems for a typical corn ethanol plant (ethanol production capacity of 170 dam 3 ). Discounted cash flow method was used to estimate both the capital and operating costs of each system and compared with the existing natural gas fired heating system. Environmental impact assessment of using corn stover, coal and natural gas in the heat and/or power generation systems was also evaluated. Coal fired process heating (PH) system had the lowest annual operating cost due to the low fuel cost, but had the highest environmental and human toxicity impacts. The proposed combined heat and power (CHP) generation system required about 137 Gg of corn stover to generate 9.5 MW of electricity and 52.3 MW of process heat with an overall CHP efficiency of 83.3%. Stover fired CHP system would generate an annual savings of 3.6 M$ with an payback period of 6 y. Economics of the coal fired CHP system was very attractive compared to the stover fired CHP system due to lower fuel cost. But the greenhouse gas emissions per Mg of fuel for the coal fired CHP system was 32 times higher than that of stover fired CHP system. Corn stover fired heat and power generation system for a corn ethanol plant can improve the net energy balance and add environmental benefits to the corn to ethanol biorefinery.

  12. Tetra-combined cogeneration system. Exergy and thermo economic evaluation; Sistema tetra combinado de cogeracao. Avaliacao exergetica e termoeconomica

    Energy Technology Data Exchange (ETDEWEB)

    Arriola, Domingo Wilson Garagatti [Sao Paulo Univ., SP (Brazil). Escola Politecnica. Dept. de Engenharia Mecanica]. E-mail: wgarriol@usp.br; Oliveira Junior, Silvio de [Instituto de Pesquisas Tecnologicas (IPT), Sao Paulo, SP (Brazil)]. E-mail: olivsilj@ipt.br

    2000-07-01

    This paper presents the description and the exergy and thermo economic evaluation of a new cogeneration system, called tetra-combined cogeneration system, that generates electricity and chilled water (for air conditioning purposes) and eventually steam. This system is composed of a gas turbine, a heat recovery steam generator, a condensation/extraction steam turbine and a hybrid absorption/steam ejection chiller. The exergy and thermo economic performance (exergy based costs of electricity, steam and chilled water production) of this system is compared with the performances of conventional cogeneration systems, pointing out the advantages and disadvantages of this new system. (author)

  13. Optimal combinations of control strategies and cost-effective analysis for visceral leishmaniasis disease transmission.

    Directory of Open Access Journals (Sweden)

    Santanu Biswas

    Full Text Available Visceral leishmaniasis (VL is a deadly neglected tropical disease that poses a serious problem in various countries all over the world. Implementation of various intervention strategies fail in controlling the spread of this disease due to issues of parasite drug resistance and resistance of sandfly vectors to insecticide sprays. Due to this, policy makers need to develop novel strategies or resort to a combination of multiple intervention strategies to control the spread of the disease. To address this issue, we propose an extensive SIR-type model for anthroponotic visceral leishmaniasis transmission with seasonal fluctuations modeled in the form of periodic sandfly biting rate. Fitting the model for real data reported in South Sudan, we estimate the model parameters and compare the model predictions with known VL cases. Using optimal control theory, we study the effects of popular control strategies namely, drug-based treatment of symptomatic and PKDL-infected individuals, insecticide treated bednets and spray of insecticides on the dynamics of infected human and vector populations. We propose that the strategies remain ineffective in curbing the disease individually, as opposed to the use of optimal combinations of the mentioned strategies. Testing the model for different optimal combinations while considering periodic seasonal fluctuations, we find that the optimal combination of treatment of individuals and insecticide sprays perform well in controlling the disease for the time period of intervention introduced. Performing a cost-effective analysis we identify that the same strategy also proves to be efficacious and cost-effective. Finally, we suggest that our model would be helpful for policy makers to predict the best intervention strategies for specific time periods and their appropriate implementation for elimination of visceral leishmaniasis.

  14. Evaluating the cost-effectiveness of combination antiretroviral therapy for the prevention of mother-to-child transmission of HIV in Uganda

    NARCIS (Netherlands)

    Kuznik, Andreas; Lamorde, Mohammed; Hermans, Sabine; Castelnuovo, Barbara; Auerbach, Brandon; Semeere, Aggrey; Sempa, Joseph; Ssennono, Mark; Ssewankambo, Fred; Manabe, Yukari C.

    2012-01-01

    Objective To model the cost-effectiveness in Uganda of combination antiretroviral therapy (ART) to prevent mother-to-child transmission of human immunodeficiency virus (HIV). Methods The cost-effectiveness of ART was evaluated on the assumption that ART reduces the risk of an HIV-positive pregnant

  15. Fuel Cell System for Transportation -- 2005 Cost Estimate

    Energy Technology Data Exchange (ETDEWEB)

    Wheeler, D.

    2006-10-01

    Independent review report of the methodology used by TIAX to estimate the cost of producing PEM fuel cells using 2005 cell stack technology. The U.S. Department of Energy (DOE) Hydrogen, Fuel Cells and Infrastructure Technologies Program Manager asked the National Renewable Energy Laboratory (NREL) to commission an independent review of the 2005 TIAX cost analysis for fuel cell production. The NREL Systems Integrator is responsible for conducting independent reviews of progress toward meeting the DOE Hydrogen Program (the Program) technical targets. An important technical target of the Program is the proton exchange membrane (PEM) fuel cell cost in terms of dollars per kilowatt ($/kW). The Program's Multi-Year Program Research, Development, and Demonstration Plan established $125/kW as the 2005 technical target. Over the last several years, the Program has contracted with TIAX, LLC (TIAX) to produce estimates of the high volume cost of PEM fuel cell production for transportation use. Since no manufacturer is yet producing PEM fuel cells in the quantities needed for an initial hydrogen-based transportation economy, these estimates are necessary for DOE to gauge progress toward meeting its targets. For a PEM fuel cell system configuration developed by Argonne National Laboratory, TIAX estimated the total cost to be $108/kW, based on assumptions of 500,000 units per year produced with 2005 cell stack technology, vertical integration of cell stack manufacturing, and balance-of-plant (BOP) components purchased from a supplier network. Furthermore, TIAX conducted a Monte Carlo analysis by varying ten key parameters over a wide range of values and estimated with 98% certainty that the mean PEM fuel cell system cost would be below DOE's 2005 target of $125/kW. NREL commissioned DJW TECHNOLOGY, LLC to form an Independent Review Team (the Team) of industry fuel cell experts and to evaluate the cost estimation process and the results reported by TIAX. The results of

  16. Cost reduction in deep water production systems

    International Nuclear Information System (INIS)

    Beltrao, R.L.C.

    1995-01-01

    This paper describes a cost reduction program that Petrobras has conceived for its deep water field. Beginning with the Floating Production Unit, a new concept of FPSO was established where a simple system, designed to long term testing, can be upgraded, on the location, to be the definitive production unit. Regarding to the subsea system, the following projects will be considered. (1) Subsea Manifold: There are two 8-well-diverless manifolds designed for 1,000 meters presently under construction and after a value analysis, a new design was achieved for the next generation. Both projects will be discussed and a cost evaluation will also be provided. (2) Subsea Pipelines: Petrobras has just started a large program aiming to reduce cost on this important item. There are several projects such as hybrid (flexible and rigid) pipes for large diameter in deep water, alternatives laying methods, rigid riser on FPS, new material...etc. The authors intend to provide an overview of each project

  17. A complete low cost radon detection system

    International Nuclear Information System (INIS)

    Bayrak, A.; Barlas, E.; Emirhan, E.; Kutlu, Ç.; Ozben, C.S.

    2013-01-01

    Monitoring the 222 Rn activity through the 1200 km long Northern Anatolian fault line, for the purpose of earthquake precursory, requires large number of cost effective radon detectors. We have designed, produced and successfully tested a low cost radon detection system (a radon monitor). In the detector circuit of this monitor, First Sensor PS100-7-CER-2 windowless PIN photodiode and a custom made transempedence/shaping amplifier were used. In order to collect the naturally ionized radon progeny to the surface of the PIN photodiode, a potential of 3500 V was applied between the conductive hemi-spherical shell and the PIN photodiode. In addition to the count rate of the radon progeny, absolute pressure, humidity and temperature were logged during the measurements. A GSM modem was integrated to the system for transferring the measurements from the remote locations to the data process center. - Author-Highlights: • Low cost radon detection. • Integrated GSM modem for early warning of radon anomalies. • Radon detection in environment

  18. Measuring Values Of Environmental Quality Improvement And Leisure Time Through Combining Contingent Valuation and Travel Cost Data

    OpenAIRE

    Young Sook Eom; Douglas M. Larson

    2004-01-01

    This paper demonstrates a utility-theoretic empirical framework for estimating values of environmental quality improvement by combining travel cost and contingent valuation data in a two-constraint (time and money) budget framework. Recgninzing the role of time "prices" and time budget, the recreation demand and willingness to pay (WTP) functiuons are specified with full price and full budget arguments, with the opportunity cost of time being a fraction of wage rate. When applied to the case ...

  19. Evaluation of a Low-Cost Bubble CPAP System Designed for Resource-Limited Settings.

    Science.gov (United States)

    Bennett, Desmond J; Carroll, Ryan W; Kacmarek, Robert M

    2018-04-01

    Respiratory compromise is a leading contributor to global neonatal death. CPAP is a method of treatment that helps maintain lung volume during expiration, promotes comfortable breathing, and improves oxygenation. Bubble CPAP is an effective alternative to standard CPAP. We sought to determine the reliability and functionality of a low-cost bubble CPAP device designed for low-resource settings. The low-cost bubble CPAP device was compared to a commercially available bubble CPAP system. The devices were connected to a lung simulator that simulated neonates of 4 different weights with compromised respiratory mechanics (∼1, ∼3, ∼5, and ∼10 kg). The devices' abilities to establish and maintain pressure and flow under normal conditions as well as under conditions of leak were compared. Multiple combinations of pressure levels (5, 8, and 10 cm H 2 O) and flow levels (3, 6, and 10 L/min) were tested. The endurance of both devices was also tested by running the systems continuously for 8 h and measuring the changes in pressure and flow. Both devices performed equivalently during the no-leak and leak trials. While our testing revealed individual differences that were statistically significant and clinically important (>10% difference) within specific CPAP and flow-level settings, no overall comparisons of CPAP or flow were both statistically significant and clinically important. Each device delivered pressures similar to the desired pressures, although the flows delivered by both machines were lower than the set flows in most trials. During the endurance trials, the low-cost device was marginally better at maintaining pressure, while the commercially available device was better at maintaining flow. The low-cost bubble CPAP device evaluated in this study is comparable to a bubble CPAP system used in developed settings. Extensive clinical trials, however, are necessary to confirm its effectiveness. Copyright © 2018 by Daedalus Enterprises.

  20. Combined solar collector and storage systems

    International Nuclear Information System (INIS)

    Norton, B.; Smyth, M.; Eames, P.; Lo, S.N.G.

    2000-01-01

    The article discusses reasons why fossil-fuelled water heating systems are included in new houses but solar systems are not. The technology and market potential for evacuated tube systems and integral collector storage systems (ICSS) are explained. The challenge for the designers of ICSSWH has been how to reduce heat loss without compromising solar energy collection. A new concept for enhanced energy storage is described in detail and input/output data are given for two versions of ICSSWH units. A table compares the costs of ICSSWH in houses compared with other (i.e. fossil fuel) water heating systems

  1. Cost analysis of Navy acquisition alternatives for the NAVSTAR Global Positioning System

    Science.gov (United States)

    Darcy, T. F.; Smith, G. P.

    1982-12-01

    This research analyzes the life cycle cost (LCC) of the Navy's current and two hypothetical procurement alternatives for NAVSTAR Global Positioning System (GPS) user equipment. Costs are derived by the ARINC Research Corporation ACBEN cost estimating system. Data presentation is in a comparative format describing individual alternative LCC and differential costs between alternatives. Sensitivity analysis explores the impact receiver-processor unit (RPU) first unit production cost has on individual alternative LCC, as well as cost differentials between each alternative. Several benefits are discussed that might provide sufficient cost savings and/or system effectiveness improvements to warrant a procurement strategy other than the existing proposal.

  2. Combined air and water pollution control system

    Science.gov (United States)

    Wolverton, Billy C. (Inventor); Jarrell, Lamont (Inventor)

    1990-01-01

    A bioaquatic air pollution control system for controlling both water and atmospheric pollution is disclosed. The pollution control system includes an exhaust for directing polluted gases out of a furnace and a fluid circulating system which circulates fluid, such as waste water, from a source, past the furnace where the fluid flow entrains the pollutants from the furnace. The combined fluid and pollutants are then directed through a rock/plant/microbial filtering system. A suction pump pumps the treated waste water from the filter system past the exhaust to again entrain more pollutants from the furnace where they are combined with the fluid (waste water) and directed to the filter system.

  3. A cost-benefit analysis for materials management information systems.

    Science.gov (United States)

    Slapak-Iacobelli, L; Wilde, A H

    1993-02-01

    The cost-benefit analysis provided the system planners with valuable information that served many purposes. It answered the following questions: Why was the CCF undertaking this project? What were the alternatives? How much was it going to cost? And what was the expected outcome? The process of developing cost-benefit the document kept the project team focused. It also motivated them to involve additional individuals from materials management and accounts payable in its development. A byproduct of this involvement was buy-in and commitment to the project by everyone in these areas. Consequently, the project became a team effort championed by many and not just one. We were also able to introduce two new information system processes: 1) a management review process with goals and anticipated results, and 2) a quality assurance process that ensured the CCF had a better product in the end. The cost-benefit analysis provided a planning tool that assisted in successful implementation of an integrated materials management information system.

  4. Cost Benefit and Alternatives Analysis of Distribution Systems with Energy Storage Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Tom; Nagarajan, Adarsh; Baggu, Murali; Bialek, Tom

    2017-06-27

    This paper explores monetized and non-monetized benefits from storage interconnected to distribution system through use cases illustrating potential applications for energy storage in California's electric utility system. This work supports SDG&E in its efforts to quantify, summarize, and compare the cost and benefit streams related to implementation and operation of energy storage on its distribution feeders. This effort develops the cost benefit and alternatives analysis platform, integrated with QSTS feeder simulation capability, and analyzed use cases to explore the cost-benefit of implementation and operation of energy storage for feeder support and market participation.

  5. Combining Water Quality and Cost-Benefit Analysis to Examine the Implications of Agricultural Best Management Practices

    Science.gov (United States)

    Rao, N. S.; Easton, Z. M.; Lee, D. R.; Steenhuis, T. S.

    2007-12-01

    Nutrient runoff from agricultural fields threatens water quality and can impair habitats in many watersheds. Agencies consider these potential risks as they determine acceptable levels of nutrient loading. For example, in the New York City (NYC) watershed, the Environmental Protection Agency's Total Maximum Daily Load (TMDL) for phosphorus (P) has been set at 15μg P L-1 to protect against eutrophication and bacterial outbreaks. In the NYC watersheds agricultural Best Management Practices (BMPs) are the primary means to control nonpoint source P loading. BMPs include riparian buffers, filter strips, manure storage facilities, crop rotation, stripcropping, tree planting and nutrient management plans (NMPs). Water quality research on BMPs to date has included studies on site-specificity of different BMPs, short and long term BMP efficacy, and placement of BMPs with respect to critical source areas. A necessary complement to studies addressing water quality aspects of different BMPs are studies examining the cost-benefit aspects of BMPs. In general, there are installment, maintenance and opportunity costs associated with each BMP, and there are benefits, including cost share agreements between farmers and farm agencies, and increased efficiency of farm production and maintenance. Combining water quality studies and related cost-benefit analyses would help planners and watershed managers determine how best improve water quality. Our research examines the costs-benefit structure associated with BMP scenarios on a one-farm headwater watershed in the Catskill Mountains of NY. The different scenarios include "with and without" BMPs, combinations of BMPs, and different BMP placements across agricultural fields. The costs associated with each BMP scenarios are determined using information from farm agencies and watershed planning agencies. With these data we perform a cost-benefit analysis for the different BMP scenarios and couple the water quality modeling using the

  6. Symbol-stream Combiner: Description and Demonstration Plans

    Science.gov (United States)

    Hurd, W. J.; Reder, L. J.; Russell, M. D.

    1984-01-01

    A system is described and demonstration plans presented for antenna arraying by symbol stream combining. This system is used to enhance the signal-to-noise ratio of a spacecraft signals by combining the detected symbol streams from two or more receiving stations. Symbol stream combining has both cost and performance advantages over other arraying methods. Demonstrations are planned on Voyager 2 both prior to and during Uranus encounter. Operational use is possible for interagency arraying of non-Deep Space Network stations at Neptune encounter.

  7. Economic evaluation of biogas and natural gas co-firing in gas turbine combined heat and power systems

    International Nuclear Information System (INIS)

    Kang, Jun Young; Kang, Do Won; Kim, Tong Seop; Hur, Kwang Beom

    2014-01-01

    This study investigated the economics of co-firing biogas and natural gas within a small gas turbine combined heat and power (CHP) plant. The thermodynamic performance of the CHP plant was calculated with varying gas mixing ratios, forming the basis for the economic analysis. A cost balance equation was used to calculate the costs of electricity and heat. The methodology was validated, and parametric analyses were used to investigate the influence of gas mixing ratio and heat sales ratio on the costs of electricity and heat. The cost of electricity generation from the CHP plant was compared to that of a central combined cycle power plant, and an economical gas mixing ratio range were suggested for various heat sales ratios. It was revealed that the effect of the heat sales ratio on the cost of electricity becomes greater as the proportion of natural gas is increased. It was also demonstrated that the economic return from the installation of CHP systems is substantially affected by the gas mixing ratio and heat sales ratio. Sensitivity analysis showed that influence of economic factors on the CHP plant is greater when a higher proportion of natural gas is used. - Highlights: • An appropriate method to calculate the costs of electricity (COE) and heat (COH) was established. • Both COE and COH increase with increasing natural gas mixing ratio and decreasing heat sales ratio. • The effect of the heat sales ratio on the COE becomes greater as the mixing ratio increases. • The payback period is considerably dependent on the mixing ratio and heat sales ratio

  8. Assessment of generic solar thermal systems for large power applications: analysis of electric power generating costs for systems larger than 10 MWe

    Energy Technology Data Exchange (ETDEWEB)

    Apley, W.J.; Bird, S.P.; Brown, D.R.; Drost, M.K.; Fort, J.A.; Garrett-Price, B.A.; Patton, W.P.; Williams, T.A.

    1980-11-01

    Seven generic types of collectors, together with associated subsystems for electric power generation, were considered. The collectors can be classified into three categories: (1) two-axis tracking (with compound-curvature reflecting surfaces); (2) one-axis tracking (with single-curvature reflecting surfaces); and (3) nontracking (with low-concentration reflecting surfaces). All seven collectors were analyzed in conceptual system configurations with Rankine-cycle engines. In addition, two of the collectors were analyzed with Brayton-cycle engines, and one was analyzed with a Stirling-cycle engine. With these engine options, and the consideration of both thermal and electrical storage for the Brayton-cycle central receiver, 11 systems were formulated for analysis. Conceptual designs developed for the 11 systems were based on common assumptions of available technology in the 1990 to 2000 time frame. No attempt was made to perform a detailed optimization of each conceptual design. Rather, designs best suited for a comparative evaluation of the concepts were formulated. Costs were estimated on the basis of identical assumptions, ground rules, methodologies, and unit costs of materials and labor applied uniformly to all of the concepts. The computer code SOLSTEP was used to analyze the thermodynamic performance characteristics and energy costs of the 11 concepts. Year-long simulations were performed using meteorological and insolation data for Barstow, California. Results for each concept include levelized energy costs and capacity factors for various combinations of storage capacity and collector field size.

  9. A Highly Reliable and Cost-Efficient Multi-Sensor System for Land Vehicle Positioning

    Directory of Open Access Journals (Sweden)

    Xu Li

    2016-05-01

    Full Text Available In this paper, we propose a novel positioning solution for land vehicles which is highly reliable and cost-efficient. The proposed positioning system fuses information from the MEMS-based reduced inertial sensor system (RISS which consists of one vertical gyroscope and two horizontal accelerometers, low-cost GPS, and supplementary sensors and sources. First, pitch and roll angle are accurately estimated based on a vehicle kinematic model. Meanwhile, the negative effect of the uncertain nonlinear drift of MEMS inertial sensors is eliminated by an H∞ filter. Further, a distributed-dual-H∞ filtering (DDHF mechanism is adopted to address the uncertain nonlinear drift of the MEMS-RISS and make full use of the supplementary sensors and sources. The DDHF is composed of a main H∞ filter (MHF and an auxiliary H∞ filter (AHF. Finally, a generalized regression neural network (GRNN module with good approximation capability is specially designed for the MEMS-RISS. A hybrid methodology which combines the GRNN module and the AHF is utilized to compensate for RISS position errors during GPS outages. To verify the effectiveness of the proposed solution, road-test experiments with various scenarios were performed. The experimental results illustrate that the proposed system can achieve accurate and reliable positioning for land vehicles.

  10. Comparing systems for costing hospital treatments. The case of stable angina pectoris.

    Science.gov (United States)

    Larsen, Jytte; Skjoldborg, Ulla Slothuus

    2004-03-01

    This paper demonstrates the basic properties in the systems most commonly considered for costing treatments in the Danish hospitals. The differences between the traditional charge system, the DRG system and the ABC system are analysed, and difficulties encountered in comparing these systems are discussed. A sample of patients diagnosed with stable angina pectoris (SAP) at Odense University Hospital was used to compare the three systems when costing an entire treatment path, costing single hospitalisations and studying the effects of length of stay. Furthermore, it is illustrated that the main idea behind each system is reflected in how the systems over- or underestimate costs. Implications when managing the hospitals, particularly reimbursement, are discussed.

  11. CECP, Decommissioning Costs for PWR and BWR

    International Nuclear Information System (INIS)

    Bierschbach, M.C.

    1997-01-01

    1 - Description of program or function: The Cost Estimating Computer Program CECP, designed for use on an IBM personal computer or equivalent, was developed for estimating the cost of decommissioning boiling water reactor (BWR) and light-water reactor (PWR) power stations to the point of license termination. 2 - Method of solution: Cost estimates include component, piping, and equipment removal costs; packaging costs; decontamination costs; transportation costs; burial volume and costs; and manpower staffing costs. Using equipment and consumables costs and inventory data supplied by the user, CECP calculates unit cost factors and then combines these factors with transportation and burial cost algorithms to produce a complete report of decommissioning costs. In addition to costs, CECP also calculates person-hours, crew-hours, and exposure person-hours associated with decommissioning. 3 - Restrictions on the complexity of the problem: The program is designed for a specific waste charge structure. The waste cost data structure cannot handle intermediate waste handlers or changes in the charge rate structures. The decommissioning of a reactor can be divided into 5 periods. 200 different items for special equipment costs are possible. The maximum amount for each special equipment item is 99,999,999$. You can support data for 10 buildings, 100 components each; ESTS1071/01: There are 65 components for 28 systems available to specify the contaminated systems costs (BWR). ESTS1071/02: There are 75 components for 25 systems available to specify the contaminated systems costs (PWR)

  12. A combined loading system integrated with portable winch and polyethylene chutes for loading of timber products

    Directory of Open Access Journals (Sweden)

    H. Hulusi Acar

    2016-01-01

    Full Text Available Truck loading operation is an important task during timber production operations in forestry. In Turkey, approximately 50 million timbers/logs are being produced per year, and then they are loaded into the logging trucks. The timber/logs are transported over the forest roads with an average of one million roundtrips. However, the traditional loading methods using manpower are mostly performed while some part is done by using loading machines which can be very costly and risky. This study aims developing a combined loading system in which heavy logs are loaded into logging trucks by pulling them by a log-line powered by a portable crane within the chute system. The slope of the log-line from ground to logging truck varied between 1% and 25%. Within the each work cycle of loading operation, only one log was loaded by pulling with portable crane. The average loading time was found as 161.8 seconds per cycle, in which 67% of the time was spent on pulling the log into the logging truck. The results indicated that the average pulling speed with crane power was 840.4 m/hr and productivity was calculated as 4.94 m3/hr. The result on system speed and productivity indicated close relations with results from previous studies. The hydraulic grapple loader or cranes are widely used and common loading machines, but they cannot be efficiently used in forestry operations, especially ones having a low timber productivity rate or having low economic value timber. In these conditions, loading methods that are cost efficient and do not require higher production rate should be employed. Therefore, a combined loading system introduced in this study can be a feasible solution for loading operations in those cases. Furthermore, it is believed that this loading system integrated with a portable crane can be cost efficient and time saving solution, as well as ergonomic and safe method in the field.

  13. Satellite Power Systems (SPS) concept definition study. Volume 2, part 2: System engineering. [cost and programmatics

    Science.gov (United States)

    Hanley, G. M.

    1980-01-01

    The latest technical and programmatic developments are considered as well as expansions of the Rockwell SPS cost model covering each phase of the program through the year 2030. Comparative cost/economic analyses cover elements of the satellite, construction system, space transportation vehicles and operations, and the ground receiving station. System plans to define time phased costs and planning requirements that support major milestones through the year 2000. A special analysis is included on natural resources required to build the SPS reference configuration. An appendix contains the SPS Work Breakdown Structure and dictionary along with detail cost data sheet on each system and main element of the program. Over 200 line items address DDT&E, theoretical first unit, investment cost per satellite, and operations charges for replacement capital and normal operations and maintenance costs.

  14. IMPLEMENTATION OF ACTIVITY BASED ANALYSIS METHOD COSTING SYSTEM IN PRICING COST OF ROOMS IN HOTEL DYNASTY MAKASSAR

    Directory of Open Access Journals (Sweden)

    Muh Nur Hatta

    2017-06-01

    Full Text Available The purpose of this study is to fulfill one of the final project now where Thesis research was held in April to June, 2016. This study aims to know the differences in the calculation of the cost of the room by using a conventional system using activity-based costing (ABC system. method analysis is using descriptive method of analysis of the cost of the hotel this time, set the conventional method and then comparing the cost of a hotel room based activity based result costing. study showed that of calculating the cost of a hotel room by using activity based costing, when compared with the cost of hotel rooms used by the activity based costing Dynasty then give the results in standard rooms, deluxe, suites and family give results the calculation of which is smaller than the cost of the rooms which have been determined by the hotel management. That is, with the difference in price for a Standard room IDR. 58024.84. For a Deluxe room IDR. 175,411.58. For room Suite IDR. 99. 034,88. Family rooms and for IDR. 100,045.60. While in the room Executive Suite / Pent House Activity Based Costing calculation result is greater than the cost of the rooms which have been determined by the hotel management. That is, with the difference amounting to IDR. 368,096.17. The difference in price is due to the method of Activity Based Costing,The overhead on each product is charged to a lot of cost driver. Thus, in the Activity Based Costing method is able to allocate activity costs to each room is right by the consumption of each activity.

  15. Investigation of Cost and Energy Optimization of Drinking Water Distribution Systems.

    Science.gov (United States)

    Cherchi, Carla; Badruzzaman, Mohammad; Gordon, Matthew; Bunn, Simon; Jacangelo, Joseph G

    2015-11-17

    Holistic management of water and energy resources through energy and water quality management systems (EWQMSs) have traditionally aimed at energy cost reduction with limited or no emphasis on energy efficiency or greenhouse gas minimization. This study expanded the existing EWQMS framework and determined the impact of different management strategies for energy cost and energy consumption (e.g., carbon footprint) reduction on system performance at two drinking water utilities in California (United States). The results showed that optimizing for cost led to cost reductions of 4% (Utility B, summer) to 48% (Utility A, winter). The energy optimization strategy was successfully able to find the lowest energy use operation and achieved energy usage reductions of 3% (Utility B, summer) to 10% (Utility A, winter). The findings of this study revealed that there may be a trade-off between cost optimization (dollars) and energy use (kilowatt-hours), particularly in the summer, when optimizing the system for the reduction of energy use to a minimum incurred cost increases of 64% and 184% compared with the cost optimization scenario. Water age simulations through hydraulic modeling did not reveal any adverse effects on the water quality in the distribution system or in tanks from pump schedule optimization targeting either cost or energy minimization.

  16. Low-Cost Metal Hydride Thermal Energy Storage System for Concentrating Solar Power Systems

    Energy Technology Data Exchange (ETDEWEB)

    Zidan, Ragaiy [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hardy, B. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Corgnale, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Teprovich, J. A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Ward, P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Motyka, Ted [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-01-31

    The objective of this research was to evaluate and demonstrate a metal hydride-based TES system for use with a CSP system. A unique approach has been applied to this project that combines our modeling experience with the extensive material knowledge and expertise at both SRNL and Curtin University (CU). Because of their high energy capacity and reasonable kinetics many metal hydride systems can be charged rapidly. Metal hydrides for vehicle applications have demonstrated charging rates in minutes and tens of minutes as opposed to hours. This coupled with high heat of reaction allows metal hydride TES systems to produce very high thermal power rates (approx. 1kW per 6-8 kg of material). A major objective of this work is to evaluate some of the new metal hydride materials that have recently become available. A problem with metal hydride TES systems in the past has been selecting a suitable high capacity low temperature metal hydride material to pair with the high temperature material. A unique aspect of metal hydride TES systems is that many of these systems can be located on or near dish/engine collectors due to their high thermal capacity and small size. The primary objective of this work is to develop a high enthalpy metal hydride that is capable of reversibly storing hydrogen at high temperatures (> 650 °C) and that can be paired with a suitable low enthalpy metal hydride with low cost materials. Furthermore, a demonstration of hydrogen cycling between the two hydride beds is desired.

  17. Cost-effectiveness analysis of optimal strategy for tumor treatment

    International Nuclear Information System (INIS)

    Pang, Liuyong; Zhao, Zhong; Song, Xinyu

    2016-01-01

    We propose and analyze an antitumor model with combined immunotherapy and chemotherapy. Firstly, we explore the treatment effects of single immunotherapy and single chemotherapy, respectively. Results indicate that neither immunotherapy nor chemotherapy alone are adequate to cure a tumor. Hence, we apply optimal theory to investigate how the combination of immunotherapy and chemotherapy should be implemented, for a certain time period, in order to reduce the number of tumor cells, while minimizing the implementation cost of the treatment strategy. Secondly, we establish the existence of the optimality system and use Pontryagin’s Maximum Principle to characterize the optimal levels of the two treatment measures. Furthermore, we calculate the incremental cost-effectiveness ratios to analyze the cost-effectiveness of all possible combinations of the two treatment measures. Finally, numerical results show that the combination of immunotherapy and chemotherapy is the most cost-effective strategy for tumor treatment, and able to eliminate the entire tumor with size 4.470 × 10"8 in a year.

  18. The costs of introducing artemisinin-based combination therapy: evidence from district-wide implementation in rural Tanzania.

    Science.gov (United States)

    Njau, Joseph D; Goodman, Catherine A; Kachur, S Patrick; Mulligan, Jo; Munkondya, John S; McHomvu, Naiman; Abdulla, Salim; Bloland, Peter; Mills, Anne

    2008-01-07

    The development of antimalarial drug resistance has led to increasing calls for the introduction of artemisinin-based combination therapy (ACT). However, little evidence is available on the full costs associated with changing national malaria treatment policy. This paper presents findings on the actual drug and non-drug costs associated with deploying ACT in one district in Tanzania, and uses these data to estimate the nationwide costs of implementation in a setting where identification of malaria cases is primarily dependant on clinical diagnosis. Detailed data were collected over a three year period on the financial costs of providing ACT in Rufiji District as part of a large scale effectiveness evaluation, including costs of drugs, distribution, training, treatment guidelines and other information, education and communication (IEC) materials and publicity. The district-level costs were scaled up to estimate the costs of nationwide implementation, using four scenarios to extrapolate variable costs. The total district costs of implementing ACT over the three year period were slightly over one million USD, with drug purchases accounting for 72.8% of this total. The composite (best) estimate of nationwide costs for the first three years of ACT implementation was 48.3 million USD (1.29 USD per capita), which varied between 21 and 67.1 million USD in the sensitivity analysis (2003 USD). In all estimates drug costs constituted the majority of total costs. However, non-drug costs such as IEC materials, drug distribution, communication, and health worker training were also substantial, accounting for 31.4% of overall ACT implementation costs in the best estimate scenario. Annual implementation costs are equivalent to 9.5% of Tanzania's recurrent health sector budget, and 28.7% of annual expenditure on medical supplies, implying a 6-fold increase in the national budget for malaria treatment. The costs of implementing ACT are substantial. Although drug purchases

  19. A cost modelling system for cloud computing

    OpenAIRE

    Ajeh, Daniel; Ellman, Jeremy; Keogh, Shelagh

    2014-01-01

    An advance in technology unlocks new opportunities for organizations to increase their productivity, efficiency and process automation while reducing the cost of doing business as well. The emergence of cloud computing addresses these prospects through the provision of agile systems that are scalable, flexible and reliable as well as cost effective. Cloud computing has made hosting and deployment of computing resources cheaper and easier with no up-front charges but pay per-use flexible payme...

  20. U.S. Solar Photovoltaic System Cost Benchmark: Q1 2017

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Ran [National Renewable Energy Lab. (NREL), Golden, CO (United States); Feldman, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States); Woodhouse, Mike [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ardani, Kristen [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-09-01

    This report benchmarks U.S. solar photovoltaic (PV) system installed costs as of the first quarter of 2017 (Q1 2017). We use a bottom-up methodology, accounting for all system and projectdevelopment costs incurred during the installation to model the costs for residential, commercial, and utility-scale systems. In general, we attempt to model the typical installation techniques and business operations from an installed-cost perspective. Costs are represented from the perspective of the developer/installer; thus, all hardware costs represent the price at which components are purchased by the developer/installer, not accounting for preexisting supply agreements or other contracts. Importantly, the benchmark also represents the sales price paid to the installer; therefore, it includes profit in the cost of the hardware, 1 along with the profit the installer/developer receives, as a separate cost category. However, it does not include any additional net profit, such as a developer fee or price gross-up, which is common in the marketplace. We adopt this approach owing to the wide variation in developer profits in all three sectors, where project pricing is highly dependent on region and project specifics such as local retail electricity rate structures, local rebate and incentive structures, competitive environment, and overall project or deal structures. Finally, our benchmarks are national averages weighted by state installed capacities.

  1. Impact of Platon ETC system on intercity trucking cost

    Directory of Open Access Journals (Sweden)

    Pogotovkina Natalya

    2017-01-01

    Full Text Available In 2015 Platon ETC System, a system of charging trucks with gross vehicle weight exceeding 12 tons, was implemented in Russia. The payment is collected as a compensation fo0 the damage caused to the federal public roads. Platon system is an additional source of financing for the road sector. However, its implementation made the carriers face the increasing costs. This paper presents the first results of the system functioning and the problems, associated with it. We consider the foreign systems of truck charging. The results of calculations, which show the effect of the toll collection on the prime cost of road freight transportation, are also presented.

  2. [Relationship between cost systems and hospital expenditure].

    Science.gov (United States)

    García-Cornejo, Beatriz; Pérez-Méndez, José A

    To analyze the relationship between the degree of development of hospital cost systems (CS) implemented by the regional health services (RHS) and the variation in unit cost of hospitals in Spanish National Health Service (NHS) between 2010 and 2013 and to identify other explanatory factors of this variation. A database of NHS hospitals was constructed from exclusively public sources. Using a multilevel regression model, explaining factors of the variation in unit cost (cost per weighted unit of activity [WAU]) of a sample of 170 hospitals were analyzed. The variables representative of the degree of development of CS are associated in a negative and significant way with the variation of the cost per WAU. It is observed that if a high-level development CS is used the cost variation per WAU would be reduced by close to 3.2%. There is also a negative and significant relationship between the variation in the cost per WAU and the variations in the percentage of high technology and the hospital occupancy rate. On the other hand, the variations in the average cost of personnel and in the number of workers per 100 beds are associated in a positive and significant way with the variation of the cost per WAU. In the period analysed, during which the main health expenditure adjustment was made, the control in hospital unit cost is associated not only with spending cuts but also with aspects related to their management, such as the implementation of more developed CS. Copyright © 2017 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. LCP- LIFETIME COST AND PERFORMANCE MODEL FOR DISTRIBUTED PHOTOVOLTAIC SYSTEMS

    Science.gov (United States)

    Borden, C. S.

    1994-01-01

    The Lifetime Cost and Performance (LCP) Model was developed to assist in the assessment of Photovoltaic (PV) system design options. LCP is a simulation of the performance, cost, and revenue streams associated with distributed PV power systems. LCP provides the user with substantial flexibility in specifying the technical and economic environment of the PV application. User-specified input parameters are available to describe PV system characteristics, site climatic conditions, utility purchase and sellback rate structures, discount and escalation rates, construction timing, and lifetime of the system. Such details as PV array orientation and tilt angle, PV module and balance-of-system performance attributes, and the mode of utility interconnection are user-specified. LCP assumes that the distributed PV system is utility grid interactive without dedicated electrical storage. In combination with a suitable economic model, LCP can provide an estimate of the expected net present worth of a PV system to the owner, as compared to electricity purchased from a utility grid. Similarly, LCP might be used to perform sensitivity analyses to identify those PV system parameters having significant impact on net worth. The user describes the PV system configuration to LCP via the basic electrical components. The module is the smallest entity in the PV system which is modeled. A PV module is defined in the simulation by its short circuit current, which varies over the system lifetime due to degradation and failure. Modules are wired in series to form a branch circuit. Bypass diodes are allowed between modules in the branch circuits. Branch circuits are then connected in parallel to form a bus. A collection of buses is connected in parallel to form an increment to capacity of the system. By choosing the appropriate series-parallel wiring design, the user can specify the current, voltage, and reliability characteristics of the system. LCP simulation of system performance is site

  4. Evolutionary systems biology of amino acid biosynthetic cost in yeast.

    Directory of Open Access Journals (Sweden)

    Michael D Barton

    2010-08-01

    Full Text Available Every protein has a biosynthetic cost to the cell based on the synthesis of its constituent amino acids. In order to optimise growth and reproduction, natural selection is expected, where possible, to favour the use of proteins whose constituents are cheaper to produce, as reduced biosynthetic cost may confer a fitness advantage to the organism. Quantifying the cost of amino acid biosynthesis presents challenges, since energetic requirements may change across different cellular and environmental conditions. We developed a systems biology approach to estimate the cost of amino acid synthesis based on genome-scale metabolic models and investigated the effects of the cost of amino acid synthesis on Saccharomyces cerevisiae gene expression and protein evolution. First, we used our two new and six previously reported measures of amino acid cost in conjunction with codon usage bias, tRNA gene number and atomic composition to identify which of these factors best predict transcript and protein levels. Second, we compared amino acid cost with rates of amino acid substitution across four species in the genus Saccharomyces. Regardless of which cost measure is used, amino acid biosynthetic cost is weakly associated with transcript and protein levels. In contrast, we find that biosynthetic cost and amino acid substitution rates show a negative correlation, but for only a subset of cost measures. In the economy of the yeast cell, we find that the cost of amino acid synthesis plays a limited role in shaping transcript and protein expression levels compared to that of translational optimisation. Biosynthetic cost does, however, appear to affect rates of amino acid evolution in Saccharomyces, suggesting that expensive amino acids may only be used when they have specific structural or functional roles in protein sequences. However, as there appears to be no single currency to compute the cost of amino acid synthesis across all cellular and environmental

  5. 40 CFR 35.928-3 - Implementation of the industrial cost recovery system.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Implementation of the industrial cost...-Clean Water Act § 35.928-3 Implementation of the industrial cost recovery system. (a) When a grantee's industrial cost recovery system is approved, implementation of the approved system shall become a condition...

  6. Diagnostic system for combine cycle power plant

    International Nuclear Information System (INIS)

    Shimizu, Yujiro; Nomura, Masumi; Tanaka, Satoshi; Ito, Ryoji; Kita, Yoshiyuki

    2000-01-01

    We developed the Diagnostic System for Combined Cycle Power Plant which enables inexperienced operators as well as experienced operators to cope with abnormal conditions of Combined Cycle Power Plant. The features of this system are the Estimate of Emergency Level for Operation and the Prediction of Subsequent Abnormality, adding to the Diagnosis of Cause and the Operation Guidance. Moreover in this system, Diagnosis of Cause was improved by using our original method and support screens can be displayed for educational means in normal condition as well. (Authors)

  7. Evaluation of a low-cost 3D sound system for immersive virtual reality training systems.

    Science.gov (United States)

    Doerr, Kai-Uwe; Rademacher, Holger; Huesgen, Silke; Kubbat, Wolfgang

    2007-01-01

    Since Head Mounted Displays (HMD), datagloves, tracking systems, and powerful computer graphics resources are nowadays in an affordable price range, the usage of PC-based "Virtual Training Systems" becomes very attractive. However, due to the limited field of view of HMD devices, additional modalities have to be provided to benefit from 3D environments. A 3D sound simulation can improve the capabilities of VR systems dramatically. Unfortunately, realistic 3D sound simulations are expensive and demand a tremendous amount of computational power to calculate reverberation, occlusion, and obstruction effects. To use 3D sound in a PC-based training system as a way to direct and guide trainees to observe specific events in 3D space, a cheaper alternative has to be provided, so that a broader range of applications can take advantage of this modality. To address this issue, we focus in this paper on the evaluation of a low-cost 3D sound simulation that is capable of providing traceable 3D sound events. We describe our experimental system setup using conventional stereo headsets in combination with a tracked HMD device and present our results with regard to precision, speed, and used signal types for localizing simulated sound events in a virtual training environment.

  8. Cost-effectiveness of combination daclatasvir-sofosbuvir for treatment of genotype 3 chronic hepatitis C infection in the United States.

    Science.gov (United States)

    Saint-Laurent Thibault, Catherine; Moorjaney, Divya; Ganz, Michael L; Sill, Bruce; Hede, Shalini; Yuan, Yong; Gorsh, Boris

    2017-07-01

    A phase III trial evaluated the efficacy and safety of Daklinza (daclatasvir or DCV) in combination with sofosbuvir (SOF) for treatment of genotype (GT) 3 hepatitis C virus (HCV) patients. This study evaluated the cost-effectiveness of DCV + SOF vs SOF in combination with ribavirin (RBV) over a 20-year time horizon from the perspective of a United States (US) payer. A published Markov model was adapted to reflect US demographic characteristics, treatment patterns, costs of drug acquisition, monitoring, disease and adverse event management, and mortality risks. Clinical inputs came from the ALLY-3 and VALENCE trials. The primary outcome was the incremental cost-utility ratio. Life-years, incidence of complications, number of patients achieving sustained virological response (SVR), and the total cost per SVR were secondary outcomes. Costs (2014 USD) and quality-adjusted life years (QALYs) were discounted at 3% per year. Deterministic, probabilistic, and scenario sensitivity analyses were conducted. DCV + SOF was associated with lower costs and better effectiveness than SOF + RBV in the base case and in almost all scenarios (i.e. treatment-experienced, non-cirrhotic, time horizons of 5, 10, and 80 years). DCV + SOF was less costly, but also slightly less effective than SOF + RBV in the cirrhotic and treatment-naïve population scenarios. Results were sensitive to variations in the probability of achieving SVR for both treatment arms. DCV + SOF costs less than $50,000 per QALY gained in 79% of all probabilistic iterations compared with SOF + RBV. DCV + SOF is a dominant option compared with SOF + RBV in the US for the overall GT 3 HCV patient population.

  9. The cost system of GSI - heavy ion facility in Darmstadt

    International Nuclear Information System (INIS)

    1979-01-01

    The paper gives an overview about the organization and the research program of the GSI (Heavy Ion Facility in Darmstadt). The cost accounting system is discussed in detail, financing, cost center accounting and cost unit accounting are described. (A.N.)

  10. Low Cost Night Vision System for Intruder Detection

    Science.gov (United States)

    Ng, Liang S.; Yusoff, Wan Azhar Wan; R, Dhinesh; Sak, J. S.

    2016-02-01

    The growth in production of Android devices has resulted in greater functionalities as well as lower costs. This has made previously more expensive systems such as night vision affordable for more businesses and end users. We designed and implemented robust and low cost night vision systems based on red-green-blue (RGB) colour histogram for a static camera as well as a camera on an unmanned aerial vehicle (UAV), using OpenCV library on Intel compatible notebook computers, running Ubuntu Linux operating system, with less than 8GB of RAM. They were tested against human intruders under low light conditions (indoor, outdoor, night time) and were shown to have successfully detected the intruders.

  11. Minimum Cost Nanosatellite Launch System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Delta Velocity Corporation proposes the development of a very low cost, highly responsive nanosat launch system. We propose to develop an integrated propulsion...

  12. The health system cost of post-abortion care in Rwanda

    Science.gov (United States)

    Vlassoff, Michael; Musange, Sabine F; Kalisa, Ina R; Ngabo, Fidele; Sayinzoga, Felix; Singh, Susheela; Bankole, Akinrinola

    2015-01-01

    Based on research conducted in 2012, we estimate the cost to the Rwandan health-care system of providing post-abortion care (PAC) due to unsafe abortions, a subject of policy importance not studied before at the national level. Thirty-nine public and private health facilities representing three levels of health care were randomly selected for data collection from key care providers and administrators for all five regions. Using an ingredients approach to costing, data were gathered on drugs, supplies, material, personnel time and hospitalization. Additionally, direct non-medical costs such as overhead and capital costs were also measured. We found that the average annual PAC cost per client, across five types of abortion complications, was $93. The total cost of PAC nationally was estimated to be $1.7 million per year, 49% of which was expended on direct non-medical costs. Satisfying all demands for PAC would raise the national cost to $2.5 million per year. PAC comprises a significant share of total expenditure in reproductive health in Rwanda. Investing more resources in provision of contraceptive services to prevent unwanted or mistimed pregnancies would likely reduce health systems costs. PMID:24548846

  13. Comparison of the leading candidate combinations of blanket materials, thermodynamic cycles, and tritium systems for full scale fusion power plants

    International Nuclear Information System (INIS)

    Fraas, A.P.

    1975-01-01

    The many possible combinations of blanket materials, tritium generation and recovery systems, and power conversion systems were surveyed and a comprehensive set of designs were generated by using a common set of ground rules that include all of the boundary conditions that could be envisioned for a full-scale commercial fusion power plant. Particular attention was given to the effects of blanket temperature on power plant cycle efficiency and economics, the interdependence of the thermodynamic cycle and the tritium recovery system, and to thermal and pressure stresses in the blanket structure. The results indicate that, of the wide variety of systems that have been considered, the most promising employs lithium recirculated in a closed loop within a niobium blanket structure and cooled with boiling potassium or cesium. This approach gives the simplest and lowest cost tritium recovery system, the lowest pressure and thermal stresses, the simplest structure with the lowest probability of a leak, the greatest resistance to damage from a plasma energy dump, and the lowest rate of plasma contamination by either outgassing or sputtering. The only other blanket materials combination that appears fairly likely to give a satisfactory tritium generation and recovery system is a lithium-beryllium fluoride-Incoloy blanket, and even this system involves major uncertainties in the effectiveness, size, and cost of the tritium recovery system. Further, the Li 2 BeF 4 blanket system has the disadvantage that the world reserves of beryllium are too limited to support a full-blown fusion reactor economy, its poor thermal conductivity leads to cooling difficulties and a requirement for a complex structure with intricate cooling passages, and this inherently leads to an expansive blanket with a relatively high probability of leaks. The other blanket materials combinations yield even less attractive systems

  14. On Modeling and Analyzing Cost Factors in Information Systems Engineering

    NARCIS (Netherlands)

    Mutschler, B.B.; Reichert, M.U.

    Introducing enterprise information systems (EIS) is usually associated with high costs. It is therefore crucial to understand those factors that determine or influence these costs. Though software cost estimation has received considerable attention during the last decades, it is difficult to apply

  15. Integration Research on Gas Turbine and Tunnel Kiln Combined System

    Science.gov (United States)

    Shi, Hefei; Ma, Liangdong; Liu, Mingsheng

    2018-04-01

    Through the integrated modeling of gas turbine and tunnel kiln combined system, a thermodynamic calculation method of combined system is put forward, and the combined system operation parameters are obtained. By this method, the optimization of the combined system is analyzed and the optimal configuration of the gas turbine is calculated. At the same time, the thermal efficiency of the combined system is analyzed, and the heat distribution and thermal efficiency of the system before and after the improvement are explained. Taking the 1500 kg/h ceramic production as an example, pointed out that if the tunnel kiln has a gas turbine with a power of 342 kw. The amount of electricity of the combined system that produced per unit volume of the fuel which consumes more than it used to will be 7.19 kwh, the system thermal efficiency will reach 57.49%, which higher than the individual gas turbine’s cycle thermal efficiency 20% at least.

  16. New waste heat district heating system with combined heat and power based on absorption heat exchange cycle in China

    International Nuclear Information System (INIS)

    Sun Fangtian; Fu Lin; Zhang Shigang; Sun Jian

    2012-01-01

    A new waste heat district heating system with combined heat and power based on absorption heat exchange cycle (DHAC) was developed to increase the heating capacity of combined heat and power (CHP) through waste heat recovery, and enhance heat transmission capacity of the existing primary side district heating network through decreasing return water temperature by new type absorption heat exchanger (AHE). The DHAC system and a conventional district heating system based on CHP (CDH) were analyzed in terms of both thermodynamics and economics. Compared to CDH, the DHAC increased heating capacity by 31% and increased heat transmission capacity of the existing primary side district heating network by 75%. The results showed that the exergetic efficiency of DHAC was 10.41% higher and the product exergy monetary cost was 36.6¥/GJ less than a CHD. DHAC is an effective way to increase thermal utilization factor of CHP, and to reduce district heating cost. - Highlights: ► Absorption heat pumps are used to recover waste heat in CHP. ► Absorption heat exchanger can reduce exergy loss in the heat transfer process. ► New waste heat heating system (DHAC) can increase heating capacity of CHP by 31%. ► DHAC can enhance heat transmission capacity of the primary pipe network by 75%. ► DHAC system has the higher exergetic efficiency and the better economic benefit.

  17. Reference costs of electricity

    International Nuclear Information System (INIS)

    Terraz, N.

    1997-01-01

    The calculation of electric power production reference costs is used in France, even in the present case of over-capacity, for comparing the relative interest of the various means of power generation (nuclear plants, coal plants, hydroelectricity, gas combined cycles, etc.) and as an aid for future investment decisions. Reference costs show a sharp decrease between 1993 and 1997 due to advancements in nuclear plant operating ability and fossil fuel price decrease. Actuarial rates, plant service life, fuel costs and exchange rates are important parameters. The various costs from the research stage to the waste processing stages are discussed and the reference costs of the various power generation systems are presented and compared together with their competitiveness; the future of wind energy and cogeneration and the prospective of the renewal of nuclear plants at the 2010 horizon are also addressed

  18. Improving environmental impact and cost assessment for supplier evaluation

    Science.gov (United States)

    Beucker, Severin; Lang, Claus

    2004-02-01

    Improving a company"s environmental and financial performance necessitates the evaluation of environmental impacts deriving from the production and cost effects of corporate actions. These effects have to be made transparent and concrete targets have to be developed. Such an evaluation has to be done on a regular basis but with limited expenses. To achieve this, different instruments of environmental controlling such as LCA and environmental performance indicators have to be combined with methods from cost accounting. Within the research project CARE (Computer Aided Resource Efficiency Accounting for Medium-Sized Enterprises), the method Resource Efficiency Accounting (REA) is used to give the participating companies new insights into hidden costs and environmental effects of their production and products. The method combines process based cost accounting with environmental impact assessment methodology and offers results that can be integrated into a company"s environmental controlling system and business processes like cost accounting, supplier assessment, etc. Much of the data necessary for the combined assessment can be available within a company"s IT system and therefore can be efficiently used for the assessment process. The project CARE puts a strong focus on the use of company data and information systems for the described assessment process and offers a methodological background for the evaluation and the structuring of such data. Besides the general approach of the project CARE the paper will present results from a case study in which the described approach is used for the evaluation of suppliers.

  19. Costs and Benefits of a Shared Digital Long-Term Preservation System

    Directory of Open Access Journals (Sweden)

    Esa-Pekka Keskitalo

    2011-10-01

    Full Text Available This paper describes the cost-benefit analysis of digital long-term preservation (LTP that was carried out in the context of the Finnish National Digital Library Project (NDL in 2010. The analysis was based on the assumption that as many as 200 archives, libraries, and museums will share an LTP system. The term ‘system’ shall be understood as encompassing not only information technology, but also human resources, organizational structures, policies and funding mechanisms. The cost analysis shows that an LTP system will incur, over the first 12 years, cumulative costs of €42 million, i.e. an average of €3.5 million per annum. Human resources and investments in information technology are the major cost factors. After the initial stages, the analysis predicts annual costs of circa €4 million. The analysis compared scenarios with and without a shared LTP system. The results indicate that a shared system will have remarkable benefits. At the development and implementation stages, a shared system shows an advantage of €30 million against the alternative scenario consisting of five independent LTP solutions. During the later stages, the advantage is estimated at €10 million per annum. The cumulative cost benefit over the first 12 years would amount to circa €100 million.

  20. Cost-effective hybrid RF/FSO backhaul solution for next generation wireless systems

    KAUST Repository

    Dahrouj, Hayssam

    2015-10-28

    The rapid pace of demand for mobile data services and the limited supply of capacity in the current wireless access networks infrastructure are leading network operators to increase the density of base station deployments to improve network performance. This densification, made possible by small-cell deployment, also brings a novel set of challenges, specifically related to the cost of ownership, in which backhaul is of primary concern. This article proposes a cost-effective hybrid RF/free-space optical (FSO) solution to combine the advantages of RF backhauls (low cost, NLOS applications) and FSO backhauls (high-rate, low latency). To first illustrate the cost advantages of the RF backhaul solution, the first part of this article presents a business case of NLOS wireless RF backhaul, which has a low cost of ownership as compared to other backhaul candidates. RF backhaul, however, is limited by latency problems. On the other side, an FSO solution, which offers better latency and higher data rate than RF backhauls, remains sensitive to weather and nature conditions (e.g., rain, fog). To combine RF and FSO advantages, the second part of this article proposes a lowcost hybrid RF/FSO solution, wherein base stations are connected to each other using either optical fiber or hybrid RF/FSO links. This part addresses the problem of minimizing the cost of backhaul planning under reliability, connectivity, and data rate constraints, and proposes choosing the appropriate cost-effective backhaul connection between BSs (i.e., either OF or hybrid RF/FSO) using graph theory techniques.

  1. An Evaluation of the Automated Cost Estimating Integrated Tools (ACEIT) System

    Science.gov (United States)

    1989-09-01

    C~4p DTIC S ELECTE fl JAN12 19 .1R ~OF S%. B -U AN EVALUATION OF THE AUTOMATED COST ESTIMATING INTEGRATED TOOLS ( ACEIT ) SYSTEM THESIS Caroline L...Ohio go 91 022 AFIT/GCA/LSQ/89S-5 AN EVALUATION OF THE AUTOMATED COST ESTIMATING INTEGRATED TOOLS ( ACEIT ) SYSTEM THESIS Caroline L. Hanson Major, USAF...Department of Defense. AFIT/GCA/LSQ/89S-5 AN EVALUATION OF THE AUTOMATED COST ESTIMATING INTEGRATED TOOLS ( ACEIT ) SYSTEM THESIS Presented to the

  2. Management information system for cost-schedule integration control for nuclear power projects

    International Nuclear Information System (INIS)

    Liu Wei; Wang Yongqing; Tian Li

    2001-01-01

    Based on the project management experience abroad and at home, a cost-schedule integration control model was developed to improve nuclear power project management. The model integrates cost data with the scheduling data by unity coding to efficiently implement cost-schedule integration control on line. The software system architecture and database is designed and implemented. The system functions include estimating and forecasting dynamically cash flow, scheduling and evaluating deviation from the cost-schedule plan, etc. The research and development of the system should improve the architecture of computer integrated management information systems for nuclear power projects in China

  3. Cost/benefit assessment in electric power systems

    International Nuclear Information System (INIS)

    Oteng-Adjei, J.

    1990-01-01

    The basic function of a modern power system is to satisfy the system load requirements as economically as possible and with a reasonable assurance of continuity and quality. The question of what is reasonable can be examined in terms of the costs and the worth to the consumer associated with providing an adequate supply. The process of preparing reliability worth estimates based on customer cost-of-interruption data is presented. These data can be derived for a particular utility service area and are used to determine appropriate customer damage functions. These indicators can be used with the basic loss of energy expectation (LOEE) index to obtain a factor that can be utilized to relate the customer losses to the worth of electric service reliability. This factor is designated as the interrupted energy assessment rate (IEAR). The developed IEAR values can be utilized in both generating capacity and composite generation and transmission system assessment. Methods for using these estimates in power system optimization at the planning stages are described and examples are used to illustrate the procedures. 106 refs., 77 figs., 64 tabs

  4. Consumer Dispersion and Logistics Costs in Various Distribution Systems

    DEFF Research Database (Denmark)

    Turkensteen, Marcel; Klose, Andreas

    We address the relationship between the geographical dispersion of a set of demand points and the expected logistics costs. This is relevant in the strategic marketing decision which groups of consumers to target. We devise quickly computable measures for the logistics costs. In our experiments......, dispersed sets of demand points are created. For various types of distribution systems, expected logistics costs are computed using continuous approximation, location and routing methodologies. We find that the average distance between locations is an effective estimate of the logistics costs....

  5. [Hospital costs estimation by micro and gross-costing approaches].

    Science.gov (United States)

    Guerre, P; Hayes, N; Bertaux, A-C

    2018-03-01

    Cost analysis has become increasingly commonplace in healthcare facilities in recent years. Regardless of the aim, the first consideration for a hospital costing process is to determine the point of view, or perspective, to adopt. Should the cost figures reflect the healthcare facility's point of view or enlighten perspectives for the public health insurance system? Another consideration is in regard to the method to adopt, as there are several. The two most widely used methods to determine the costs of hospital treatments in France are the micro-costing method and the gross-costing method. The aims of this work are: (1) to describe each of these methods (e.g. data collection, assignment of monetary value to resource consumption) with their advantages and shortcomings as they relate to the difficulties encountered with their implementation in hospitals; (2) to present a review of the literature comparing the two methods and their possible combination; and (3) to propose ways to address the questions that need to be asked before compiling resource consumption data and assigning monetary value to hospital costs. A final diagram summarizes methodologies to be preferred according to the evaluation strategy and the impact on patient care. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  6. Preliminary Cost Estimates for Nuclear Hydrogen Production: HTSE System

    International Nuclear Information System (INIS)

    Yang, K. J.; Lee, K. Y.; Lee, T. H.

    2008-01-01

    KAERI is now focusing on the research and development of the key technologies required for the design and realization of a nuclear hydrogen production system. As a preliminary study of cost estimates for nuclear hydrogen systems, the hydrogen production costs of the nuclear energy sources benchmarking GTMHR and PBMR are estimated in the necessary input data on a Korean specific basis. G4-ECONS was appropriately modified to calculate the cost for hydrogen production of HTSE (High Temperature Steam Electrolysis) process with VHTR (Very High Temperature nuclear Reactor) as a thermal energy source. The estimated costs presented in this paper show that hydrogen production by the VHTR could be competitive with current techniques of hydrogen production from fossil fuels if CO 2 capture and sequestration is required. Nuclear production of hydrogen would allow large-scale production of hydrogen at economic prices while avoiding the release of CO 2 . Nuclear production of hydrogen could thus become the enabling technology for the hydrogen economy. The major factors that would affect the cost of hydrogen were also discussed

  7. As Easy as ABC: Re-engineering the Cost Accounting System.

    Science.gov (United States)

    Trussel, John M.; Bitner, Larry N.

    1996-01-01

    To be useful for management decision making, the college or university's cost accounting system must capture and measure improvements. Activity-based costing (ABC), which determines more accurately the full costs of services and products, tracks improvements and should proceed alongside reengineering of institutional accounting. Guidelines are…

  8. The costs of introducing artemisinin-based combination therapy: evidence from district-wide implementation in rural Tanzania

    Directory of Open Access Journals (Sweden)

    Abdulla Salim

    2008-01-01

    Full Text Available Abstract Background The development of antimalarial drug resistance has led to increasing calls for the introduction of artemisinin-based combination therapy (ACT. However, little evidence is available on the full costs associated with changing national malaria treatment policy. This paper presents findings on the actual drug and non-drug costs associated with deploying ACT in one district in Tanzania, and uses these data to estimate the nationwide costs of implementation in a setting where identification of malaria cases is primarily dependant on clinical diagnosis. Methods Detailed data were collected over a three year period on the financial costs of providing ACT in Rufiji District as part of a large scale effectiveness evaluation, including costs of drugs, distribution, training, treatment guidelines and other information, education and communication (IEC materials and publicity. The district-level costs were scaled up to estimate the costs of nationwide implementation, using four scenarios to extrapolate variable costs. Results The total district costs of implementing ACT over the three year period were slightly over one million USD, with drug purchases accounting for 72.8% of this total. The composite (best estimate of nationwide costs for the first three years of ACT implementation was 48.3 million USD (1.29 USD per capita, which varied between 21 and 67.1 million USD in the sensitivity analysis (2003 USD. In all estimates drug costs constituted the majority of total costs. However, non-drug costs such as IEC materials, drug distribution, communication, and health worker training were also substantial, accounting for 31.4% of overall ACT implementation costs in the best estimate scenario. Annual implementation costs are equivalent to 9.5% of Tanzania's recurrent health sector budget, and 28.7% of annual expenditure on medical supplies, implying a 6-fold increase in the national budget for malaria treatment. Conclusion The costs of

  9. Avoided operating costs in thermal generating systems

    International Nuclear Information System (INIS)

    Chowdhury, N.; Billinton, R.; Gupta, R.

    1995-01-01

    A simple and straightforward technique was developed to assess avoided system operating costs associated with non-utility generation (NUG). The technique was based on optimum loading configurations of the committed units both before and after the inclusion of NUG energy. The salient features of the technique were presented in this paper. Assessment of avoided operating cost with deterministic and probabilistic criteria were explained. A time differentiated price system was adopted in the algorithms to reflect the different value placed on purchased price by a utility at different times of the day. The algorithms show the utility effects of dispatchable and non-dispatchable NUG energies. The IEEE Reliability Test System (RTS) was utilized for numerical analysis. Results were illustrated. It was found that sensitivity studies similar to those performed on the IEEE-RTS could be utilized to determine the amount of energy and the time period during which utilities and NUGs can maximize their economic benefits. 7 refs., 5 figs., 1 tab

  10. Cost analysis of lasers for a laser isotope separation system. Final report

    International Nuclear Information System (INIS)

    Mail, R.A.; Markovich, F.J.; Carr, R.H.

    1977-01-01

    To be of practical significance, laser isotope separation (LIS) for separation of 235 U from 238 U must exhibit attributes which make it preferable to expansion of the present facilities. Clearly the most attractive such attribute is the prospect of significant cost reductions, which preliminary studies at LLL suggest will amount to a factor of three and perhaps as much as ten. From these preliminary studies, it appears that the lasers themselves account for a very substantial portion of the capital cost of a LIS system, and a significant portion of the equipment replacement costs. Since the laser costs are so pivotal to the system cost, and the system cost is so pivotal to the choice of separation techniques, it is clear that a more detailed investigation of laser costs is required. Results are presented of a study performed by General Research Corporation (GRC) to assess the cost of lasers in a production laser isotope separation (LIS) plant

  11. Conceptual Design of a Medium-Sized Combined Smart Photovoltaic - Agriculture System - Case Study in Malaysia

    Directory of Open Access Journals (Sweden)

    Djojodihardjo Harijono

    2016-01-01

    Full Text Available With the backdrop of sustainable environment, Photo-Voltaic Power System linked to Climate-Smart Agriculture may offer solutions for Sustainable Energy, Climate Change mitigation and Sustainable Agriculture. An overview of the scope, extent and options of such combined - Co-Located PV Agricultural System appropriate for South East Asian setting, in particular, Malaysia and Indonesia is elaborated, for preliminary insight on steps and choices that have to be taken in undertaking such venture. Possible photovoltaic (PV system installation and estimate the cost, performance, and site impacts of different PV options are discussed. Technical, financing and procedural aspects that could assist in the implementation of a Co-located PV system at the site should then be studied for decision options. A brief Framework for Conceptual Design of Co-Located PV-Agricultural System Plant is outlined.

  12. Comparing the life cycle costs of using harvest residue as feedstock for small- and large-scale bioenergy systems (part II)

    International Nuclear Information System (INIS)

    Cleary, Julian; Wolf, Derek P.; Caspersen, John P.

    2015-01-01

    In part II of our two-part study, we estimate the nominal electricity generation and GHG (greenhouse gas) mitigation costs of using harvest residue from a hardwood forest in Ontario, Canada to fuel (1) a small-scale (250 kW e ) combined heat and power wood chip gasification unit and (2) a large-scale (211 MW e ) coal-fired generating station retrofitted to combust wood pellets. Under favorable operational and regulatory conditions, generation costs are similar: 14.1 and 14.9 cents per kWh (c/kWh) for the small- and large-scale facilities, respectively. However, GHG mitigation costs are considerably higher for the large-scale system: $159/tonne of CO 2 eq., compared to $111 for the small-scale counterpart. Generation costs increase substantially under existing conditions, reaching: (1) 25.5 c/kWh for the small-scale system, due to a regulation mandating the continual presence of an operating engineer; and (2) 22.5 c/kWh for the large-scale system due to insufficient biomass supply, which reduces plant capacity factor from 34% to 8%. Limited inflation adjustment (50%) of feed-in tariff rates boosts these costs by 7% to 11%. Results indicate that policy generalizations based on scale require careful consideration of the range of operational/regulatory conditions in the jurisdiction of interest. Further, if GHG mitigation is prioritized, small-scale systems may be more cost-effective. - Highlights: • Generation costs for two forest bioenergy systems of different scales are estimated. • Nominal electricity costs are 14.1–28.3 cents/kWh for the small-scale plant. • Nominal electricity costs are 14.9–24.2 cents/kWh for the large-scale plant. • GHG mitigation costs from displacing coal and LPG are $111-$281/tonne of CO 2 eq. • High sensitivity to cap. factor (large-scale) and labor requirements (small-scale)

  13. Construction of VLCC marine oil storage cost index system

    Science.gov (United States)

    Li, Yuan; Li, Yule; Lu, Jinshu; Wu, Wenfeng; Zhu, Faxin; Chen, Tian; Qin, Beichen

    2018-04-01

    VLCC as the research object, the basic knowledge of VLCC is summarized. According to the phenomenon that VLCC is applied to offshore oil storage gradually, this paper applies the theoretical analysis method to analyze the excess capacity from VLCC, the drop of oil price, the aging VLCC is more suitable for offshore storage The paper analyzes the reason of VLCC offshore oil storage from three aspects, analyzes the cost of VLCC offshore storage from the aspects of manpower cost and shipping cost, and constructs the cost index system of VLCC offshore oil storage.

  14. Empirical study of ERP systems implementation costs in Swiss SMES

    NARCIS (Netherlands)

    Equey, C.; Kusters, R.J.; Varone, S.; Montandon, N.; Cordeiro, J.; Felipe, J.

    2008-01-01

    Based on sparse literature investigating the cost of ERP systems implementation, our research uses data from a survey of Swiss SMEs having implemented ERP in order to test cost drivers. The main innovation is the proposition of a new classification of cost drivers that depend on the enterprise

  15. A Cost Benefit Analysis of an Accelerator Driven Transmutation System

    International Nuclear Information System (INIS)

    Westlen, D.; Gudowski, W.; Wallenius, J.; Tucek, K.

    2002-01-01

    This paper estimates the economical costs and benefits associated with a nuclear waste transmutation strategy. An 800 MWth, fast neutron spectrum, subcritical core design has been used in the study (the so called Sing-Sing Core). Three different fuel cycle scenarios have been compared. The main purpose of the paper has been to identify the cost drivers of a partitioning and transmutation strategy, and to estimate the cost of electricity generated in a nuclear park with operating accelerator driven systems. It has been found that directing all transuranic discharges from spent light water reactor (LWR) uranium oxide (UOX) fuel to accelerator driven systems leads to a cost increase for nuclear power of 50±15%, while introduction of a mixed oxide (MOX) burning step in the LWRs diminishes the cost penalty to 35±10%. (authors)

  16. Costs and benefits with public and investor-owned electric systems

    International Nuclear Information System (INIS)

    Bronner, K.M.

    1990-01-01

    This article discusses the analysis of the costs and benefits associated with public ownership of major utility projects and systems as opposed to private ownership. The topics discussed include the alleged benefits of public power systems, principles of cost benefit analysis, tax-exempt debt, state and local taxes and federal income taxes, benefit of 100 percent debt financing

  17. Competitiveness of CO2 capture from an industrial solid oxide fuel cell combined heat and power system in the early stage of market introduction

    NARCIS (Netherlands)

    Kuramochi, T.; Turkenburg, W.C.; Faaij, A.P.C.

    2011-01-01

    In this article, it was investigated whether potentially low-cost CO2 capture from SOFC systems could enhance the penetration of SOFC in the energy market in a highly carbon-constrained society in the mid-term future (up to year 2025). The application of 5 MWe SOFC systems for industrial combined

  18. Avoiding adverse employment effects from electricity taxation in Norway: What does it cost?

    International Nuclear Information System (INIS)

    Bjertnaes, Geir H.

    2011-01-01

    Welfare analyses of energy taxes typically show that systems with uniform rates perform better than differentiated systems. However, most western countries include some exemptions for their energy-intensive export industries and thereby avoid this potential welfare gain. find that uniform taxation of carbon emissions in combination with a wage subsidy preserves jobs in these industries at a lower welfare cost compared with a differentiated system. The wage subsidy scheme generates a substantial welfare gain per job saved. This study, however, finds that welfare costs are substantial when less accurate policy measures, represented by production-dependent subsidies, protect jobs in Norwegian electricity-intensive industries. The welfare cost per job preserved by this subsidy scheme amounts to approximately 60% of the wage cost per job, suggesting that these jobs are expensive to preserve. A uniform electricity tax combined with production-dependent subsidies preserves jobs at a lower welfare cost compared with the current differentiated electricity tax system. - Highlights: → Avoiding adverse employment effects from electricity taxation is costly in Norway. → Uniform Norwegian electricity tax with job-preserving subsidies improves welfare. → The welfare cost of Norwegian job-saving subsidies amounts to 60% of the wage.

  19. Stand-alone flat-plate photovoltaic power systems: System sizing and life-cycle costing methodology for Federal agencies

    Science.gov (United States)

    Borden, C. S.; Volkmer, K.; Cochrane, E. H.; Lawson, A. C.

    1984-01-01

    A simple methodology to estimate photovoltaic system size and life-cycle costs in stand-alone applications is presented. It is designed to assist engineers at Government agencies in determining the feasibility of using small stand-alone photovoltaic systems to supply ac or dc power to the load. Photovoltaic system design considerations are presented as well as the equations for sizing the flat-plate array and the battery storage to meet the required load. Cost effectiveness of a candidate photovoltaic system is based on comparison with the life-cycle cost of alternative systems. Examples of alternative systems addressed are batteries, diesel generators, the utility grid, and other renewable energy systems.

  20. Summing up the parts. Combining Policy Instruments for Least-Cost Climate Mitigation Strategies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    Meeting the enormous challenge of decarbonising world energy systems will require a rapid expansion of investment in clean technologies on a global scale. Mobilising these resources will be a daunting task, and it is important to undertake the transition at the lowest cost possible. This paper seeks to provide some guidance on climate change policy-making within real-world constraints, focusing on the justification of policies to supplement a carbon price, interactions between carbon pricing and supplementary policies, and management of these interactions to enable a least-cost policy response.

  1. Load control services in the management of power system security costs

    International Nuclear Information System (INIS)

    Jayantilal, A.; Strbac, G.

    1999-01-01

    The new climate of deregulation in the electricity industry is creating a need for a more transparent cost structure and within this framework the cost of system security has been a subject of considerable interest. Traditionally power system security has been supplied by out-of-merit generation, in the short term, and transmission reinforcement, in the long term. This paper presents a method of analysing the role of load-demand in the management of power system security costs by utilising load control services (LCS). It also proposes a competitive market to enable bidding from various participants within the electricity industry to supply system security. (author)

  2. Efficient, Low Cost Dish Concentrator for a CPV Based Cogeneration System

    Science.gov (United States)

    Chayet, Haim; Kost, Ori; Moran, Rani; Lozovsky, Ilan

    2011-12-01

    Zenith Solar Ltd has developed efficient electricity and heat co-generation system based on segmented-parabolic dish of total aperture area of 11 m2 and water cooled dense array module combined of triple junction cells. Conventional parabolic dishes are inherently inefficient in the sense that the radiant flux distribution is non uniform causing inefficient generation by the PV array. Secondary optics improves uniformity but introduces additional complexity and losses to the system. Zenith's dish is assembled of 1200 flat mirrors of approximately 100 cm2 each. Every mirror facet has a unique shape such that the geometrical projection from each mirror on the focal plane is essentially the same. When perfectly aligned, the projected radiation from all mirrors overlaps uniformly on the PV surface. The low cost construction of the dish utilizes plastic mount supported by a precise metal frame. The precision of the metal frame affects the overall optical efficiency of the mirror and hence the efficiency of the system. State of the art dish of 11 m2 active aperture results in output of 2.25 kWp (900 W/m2) electrical and 5 kWp thermal power from one dish system representing 21% electrical and 50% thermal conversion efficiency adding to 71% overall system efficiency.

  3. Cost-efficiency of animal welfare in broiler production systems

    NARCIS (Netherlands)

    Gocsik, Éva; Brooshooft, Suzanne D.; Jong, de Ingrid C.; Saatkamp, Helmut W.

    2016-01-01

    Broiler producers operate in a highly competitive and cost-price driven environment. In addition, in recent years the societal pressure to improve animal welfare (AW) in broiler production systems is increasing. Hence, from an economic and decision making point of view, the cost-efficiency of

  4. Cost-effective implementation of intelligent systems

    Science.gov (United States)

    Lum, Henry, Jr.; Heer, Ewald

    1990-01-01

    Significant advances have occurred during the last decade in knowledge-based engineering research and knowledge-based system (KBS) demonstrations and evaluations using integrated intelligent system technologies. Performance and simulation data obtained to date in real-time operational environments suggest that cost-effective utilization of intelligent system technologies can be realized. In this paper the rationale and potential benefits for typical examples of application projects that demonstrate an increase in productivity through the use of intelligent system technologies are discussed. These demonstration projects have provided an insight into additional technology needs and cultural barriers which are currently impeding the transition of the technology into operational environments. Proposed methods which addresses technology evolution and implementation are also discussed.

  5. Internal Logistics System Selection with Total Cost of Ownership Analysis

    Science.gov (United States)

    Araújo, Inês; Pimentel, Carina; Godina, Radu; Matias, João C. O.

    2017-06-01

    In this paper a methodology was followed in order to support the decision-making of one industrial unit regarding its internal logistics system. The addressed factory was facing issues with their internal logistics approach. Some alternatives were pointed out and a proper total cost of ownership (TCO) analysis was developed. This analysis was taken in order to demonstrate the more cost-effective solution for the internal logistics system. This tool is more and more valued by the companies, due to their willing to reduce the costs that are associated with the way of doing business. Despite the proposal of the best choice for the internal logistics system of the enterprise, this study also intends to present some conclusions about the match between the nature of the industrial unit and the logistics systems that best fit the requirements of those.

  6. Resilient guaranteed cost control of a power system.

    Science.gov (United States)

    Soliman, Hisham M; Soliman, Mostafa H; Hassan, Mohammad F

    2014-05-01

    With the development of power system interconnection, the low-frequency oscillation is becoming more and more prominent which may cause system separation and loss of energy to consumers. This paper presents an innovative robust control for power systems in which the operating conditions are changing continuously due to load changes. However, practical implementation of robust control can be fragile due to controller inaccuracies (tolerance of resistors used with operational amplifiers). A new design of resilient (non-fragile) robust control is given that takes into consideration both model and controller uncertainties by an iterative solution of a set of linear matrix inequalities (LMI). Both uncertainties are cast into a norm-bounded structure. A sufficient condition is derived to achieve the desired settling time for damping power system oscillations in face of plant and controller uncertainties. Furthermore, an improved controller design, resilient guaranteed cost controller, is derived to achieve oscillations damping in a guaranteed cost manner. The effectiveness of the algorithm is shown for a single machine infinite bus system, and then, it is extended to multi-area power system.

  7. Dynamic modeling and simulation of power transformer maintenance costs

    Directory of Open Access Journals (Sweden)

    Ristić Olga

    2016-01-01

    Full Text Available The paper presents the dynamic model of maintenance costs of the power transformer functional components. Reliability is modeled combining the exponential and Weibull's distribution. The simulation was performed with the aim of corrective maintenance and installation of the continuous monitoring system of the most critical components. Simulation Dynamic System (SDS method and VENSIM PLE software was used to simulate the cost. In this way, significant savings in maintenance costs will be achieved with a small initial investment. [Projekat Ministarstva nauke Republike Srbije, br. III 41025 i br. OI 171007

  8. PENERAPAN ACTIVITY BASED COSTING SYSTEM DALAM PERHITUNGAN PROFITABILITAS PRODUK PADA UD. NIAGA BAKTI

    Directory of Open Access Journals (Sweden)

    Fena Ulfa Aulia

    2015-06-01

    Full Text Available The Charge imposition of factory overhead based on traditional systems often cause distorted costs. One of efforts to overcome these distortions fees is with charging the costs  factory overhead  by the activity based costing. The use of activity based costing can also help companies that produce many products  in determining the level of profitability. Profitability indicates whether an enterprise has good prospects in the future for the company's survival. This research is a quantitative descriptive research conducted at UD NIAGA BAKTI engaged in the processing of tuna fish PETIS in Pamekasan located in the village of Konang, Subdistrict of Galis, Regency of Pamekasan. The type of data  used in this research is quantitative data obtained by direct observation and Interview. This techniques of research analysis calculates and compares the products profitability of PETIS by using traditional cost systems and costing system based activity. The results of this research indicates that there are differences in the principal cost of production and profitability UD NIAGA BAKTI by using activity based costing compared  Traditional Cost Systems.

  9. Cost-effectiveness analysis of computerized ECG interpretation system in an ambulatory health care organization.

    Science.gov (United States)

    Carel, R S

    1982-04-01

    The cost-effectiveness of a computerized ECG interpretation system in an ambulatory health care organization has been evaluated in comparison with a conventional (manual) system. The automated system was shown to be more cost-effective at a minimum load of 2,500 patients/month. At larger monthly loads an even greater cost-effectiveness was found, the average cost/ECG being about $2. In the manual system the cost/unit is practically independent of patient load. This is primarily due to the fact that 87% of the cost/ECG is attributable to wages and fees of highly trained personnel. In the automated system, on the other hand, the cost/ECG is heavily dependent on examinee load. This is due to the relatively large impact of equipment depreciation on fixed (and total) cost. Utilization of a computer-assisted system leads to marked reduction in cardiologists' interpretation time, substantially shorter turnaround time (of unconfirmed reports), and potential provision of simultaneous service at several remotely located "heart stations."

  10. System-wide impacts of environmental cost factors

    International Nuclear Information System (INIS)

    Rogers, M.; Kennedy, T.; Finnell, J.; Hoelscher, J.

    1992-01-01

    This paper presents a continuum of approaches to considering environmental externalities in the utility resource selection process. While photovoltaic (PV) technologies can play a role in reducing emissions, they are generally not cost-competitive with conventional technologies, even when cost estimates for environmental damages are introduced. Several approaches are explored to determine whether PV becomes more competitive when emission reduction strategies are considered on a regional basis. Finally, preliminary analysis was performed with the Midas utility planning model to develop emission credits based on PV's ability to displace emissions on a net system basis

  11. Cost-benefit analysis of electronic medical record system at a tertiary care hospital.

    Science.gov (United States)

    Choi, Jong Soo; Lee, Woo Baik; Rhee, Poong-Lyul

    2013-09-01

    Although Electronic Medical Record (EMR) systems provide various benefits, there are both advantages and disadvantages regarding its cost-effectiveness. This study analyzed the economic effects of EMR systems using a cost-benefit analysis based on the differential costs of managerial accounting. Samsung Medical Center (SMC) is a general hospital in Korea that developed an EMR system for outpatients from 2006 to 2008. This study measured the total costs and benefits during an 8-year period after EMR adoption. The costs include the system costs of building the EMR and the costs incurred in smoothing its adoption. The benefits included cost reductions after its adoption and additional revenues from both remodeling of paper-chart storage areas and medical transcriptionists' contribution. The measured amounts were discounted by SMC's expected interest rate to calculate the net present value (NPV), benefit-cost ratio (BCR), and discounted payback period (DPP). During the analysis period, the cumulative NPV and the BCR were US$3,617 thousand and 1.23, respectively. The DPP was about 6.18 years. Although the adoption of an EMR resulted in overall growth in administrative costs, it is cost-effective since the cumulative NPV was positive. The positive NPV was attributed to both cost reductions and additional revenues. EMR adoption is not so attractive to management in that the DPP is longer than 5 years at 6.18 and the BCR is near 1 at 1.23. However, an EMR is a worthwhile investment, seeing that this study did not include any qualitative benefits and that the paper-chart system was cost-centric.

  12. Cost evaluation of clinical laboratory in Taiwan's National Health System by using activity-based costing.

    Science.gov (United States)

    Su, Bin-Guang; Chen, Shao-Fen; Yeh, Shu-Hsing; Shih, Po-Wen; Lin, Ching-Chiang

    2016-11-01

    To cope with the government's policies to reduce medical costs, Taiwan's healthcare service providers are striving to survive by pursuing profit maximization through cost control. This article aimed to present the results of cost evaluation using activity-based costing performed in the laboratory in order to throw light on the differences between costs and the payment system of National Health Insurance (NHI). This study analyzed the data of costs and income of the clinical laboratory. Direct costs belong to their respective sections of the department. The department's shared costs, including public expenses and administrative assigned costs, were allocated to the department's respective sections. A simple regression equation was created to predict profit and loss, and evaluate the department's break-even point, fixed cost, and contribution margin ratio. In clinical chemistry and seroimmunology sections, the cost per test was lower than the NHI payment and their major laboratory tests had revenues with the profitability ratio of 8.7%, while the other sections had a higher cost per test than the NHI payment and their major tests were in deficit. The study found a simple linear regression model as follows: "Balance=-84,995+0.543×income (R2=0.544)". In order to avoid deficit, laboratories are suggested to increase test volumes, enhance laboratory test specialization, and become marginal scale. A hospital could integrate with regional medical institutions through alliances or OEM methods to increase volumes to reach marginal scale and reduce laboratory costs, enhancing the level and quality of laboratory medicine.

  13. Thermoeconomic Optimization of a Combined Heating and Humidification Coil for HVAC Systems

    Science.gov (United States)

    Teodoros, Liliana; Andresen, Bjarne

    2016-07-01

    The total cost of ownership is calculated for a combined heating and humidification coil of an air-handling unit taking into account investment and operation costs simultaneously. This total cost represents the optimization function for which the minimum is sought. The parameters for the cost dependencies are the physical dimensions of the coil: length, width and height. The term "coil" is used generically since in this setup it generates heating as well as humidification in a single unit. The first part of the paper deals with the constructive optimization and finds the relationship between the dimensions for a minimum cost. The second part of the paper takes the results of the constructive optimization further and, based on the data derived in our previous papers, analyzes the minimum total cost for the humidification coil while balancing the amount of water used to humidify the air and modify its temperature.

  14. Managing the Cost of Plant Piping System Leakage

    International Nuclear Information System (INIS)

    Jenco, John M.; Keck, Donna R.; Johnson, Gary L.

    2002-01-01

    Recent studies have shown that the average annual cost impact of external piping system leakage on commercial nuclear plant operations and maintenance can easily range into the millions of dollars for each reactor unit. Evidence suggests that this significant O and M cost reduction opportunity has largely been overlooked, due to the number of diverse line items and budget areas affected. Results released last year from an EPRI pilot study of more than a dozen reactor units at seven plant sites operated by multiple utilities found that the average annual cost impact was indeed around $1.6 million per year per unit. Subsequent field experience has also demonstrated that an effective fluid leak management program can substantially reduce these costs within the first three years of implementation. This paper presents the general cost impact research results from various studies, outlines key elements of an effective plant fluid leak management program, discusses important implementation issues, and presents results from case studies covering different utility approaches to developing and implementing an effective fluid leak management program. Actual cost data will be included where appropriate. (authors)

  15. Coherent combining pulse bursts in time domain

    Science.gov (United States)

    Galvanauskas, Almantas

    2018-01-09

    A beam combining and pulse stacking technique is provided that enhances laser pulse energy by coherent stacking pulse bursts (i.e. non-periodic pulsed signals) in time domain. This energy enhancement is achieved by using various configurations of Fabry-Perot, Gires-Tournois and other types of resonant cavities, so that a multiple-pulse burst incident at either a single input or multiple inputs of the system produces an output with a solitary pulse, which contains the summed energy of the incident multiple pulses from all beams. This disclosure provides a substantial improvement over conventional coherent-combining methods in that it achieves very high pulse energies using a relatively small number of combined laser systems, thus providing with orders of magnitude reduction in system size, complexity, and cost compared to current combining approaches.

  16. Systems principles of planning the net cost of oil and gas extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ryazanova, N I

    1979-01-01

    The automated system of calculation of ASPC ''oil extraction'' is developed in order to improve the existing system of planning of the oil extracting sector. The most complete expression of the systems construction of the plan is found in the section ''net cost and profit.'' Unity of the production process advances definite requirements for construction of the plan for net cost of oil and gas extraction as the model of this unified process. According to these requirements, the plan for net cost must be developed on the basis of interrelationship of the indicators of the plan for net cost within the section and with indicators of other sections of the plan, methodological unity and continuity of the methods of planning net cost by elements of outlays, articles of calculation and technical-economic factors, methodological continuity of regimes and stages of planning, as well as based on methodological continuity of the control levels. The listed requirements are principles for systems planning of the net cost of oil and gas extraction. These principles guarantee improvement in planning of net cost of oil and gas extraction according to the requirements made for the national economic planning.

  17. Profitability indicators of milk production cost center in intensive systems of production

    Directory of Open Access Journals (Sweden)

    Glauber dos Santos

    2012-01-01

    Full Text Available The objective was to estimate some profitability indicators of dairy cost center farms with a high volume of daily production in feedlot. The Intended was also to identify the components that had the greatest influence on the operational cost. We used data from three milk systems production, with the origin of the purebred Holsteins. It was considered as a milk cost center production all expenses related in lactating and dry cows. The methodology used total cost and operating cost in profitability analysis. A production system, by presenting gross margin, net positive result, was able to produce short, medium and long term. Another production system had a positive gross margin and net, with conditions to survive in the short and medium term. Finally, the third system of production has shown a negative gross margin presenting decapitalizing and entering into debt, as revenues were not enough to pay operating expenses even effective. The component items of the effective operational cost that exercised higher “impact” cost and income from milk were, in decreasing order, the feeding, labor, miscellaneous expenses, sanitation, energy, milking, reproduction, equipment rental, BST and taxes.

  18. Life Cycle Costing Model for Solid Waste Management

    DEFF Research Database (Denmark)

    Martinez-Sanchez, Veronica; Astrup, Thomas Fruergaard

    2014-01-01

    To ensure sustainability of solid waste management, there is a need for cost assessment models which are consistent with environmental and social assessments. However, there is a current lack of standardized terminology and methodology to evaluate economic performances and this complicates...... LCC, e.g. waste generator, waste operator and public finances and the perspective often defines the systemboundaries of the study, e.g. waste operators often focus on her/his own cost, i.e. technology based,whereas waste generators and public finances often focus on the entire waste system, i.......e. system based. Figure 1 illustrates the proposed modeling framework that distinguishes between: a) budget cost, b) externality costs and 3) transfers and defines unit costs of each technology (per ton of input waste). Unitcosts are afterwards combined with a mass balance to calculate the technology cost...

  19. The cost of integration of parabolic trough CSP plants in isolated Mediterranean power systems

    International Nuclear Information System (INIS)

    Poullikkas, Andreas; Hadjipaschalis, Ioannis; Kourtis, George

    2010-01-01

    In this work, a technical and economic analysis concerning the integration of parabolic trough concentrated solar power (CSP) technologies, with or without thermal storage capability, in an existing typical small isolated Mediterranean power generation system, in the absence of a feed-in tariff scheme, is carried out. In addition to the business as usual (BAU) scenario, five more scenarios are examined in the analysis in order to assess the electricity unit cost with the penetration of parabolic trough CSP plants of 50 MWe or 100 MWe, with or without thermal storage capability. Based on the input data and assumptions made, the simulations indicated that the scenario with the utilization of a single parabolic trough CSP plant (either 50 MWe or 100 MWe and with or without thermal storage capability) in combination with BAU will effect an insignificant change in the electricity unit cost of the generation system compared to the BAU scenario. In addition, a sensitivity analysis on natural gas price, showed that increasing fuel prices and the existence of thermal storage capability in the CSP plant make this scenario marginally more economically attractive compared to the BAU scenario. (author)

  20. Numerical Analysis of Combined Valve Hydrodynamic Characteristics for Turbine System

    International Nuclear Information System (INIS)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Arif, M.; Suh, Kune Y.

    2014-01-01

    precisely by the valve manufacturer. As a matter of fact, attempts were made to obtain flow characteristic curves resorting to analytical as well as numerical methods. The flow characteristic curve relates the stem lift with mass flow rate at a specific temperature and pressure. This paper focuses on computational and numerical analysis of the combined stop and control valve. Combined Airflow Regulation Analysis (CARA) is performed to check on the hydrodynamic characteristic, which is represented by flow coefficient characteristic. CATIA V.5 and ANSYS CFX are used for three-dimensional computer-aided design and computational fluid dynamics (CFD) analysis, respectively. Flow characteristic curves are plotted by calculating theoretical and numerical mass flow rate. Hydrodynamic analysis was made of the combined stop and control valve for the turbine system using ANSYS CFX. The result of the numerical study represented by the valve flow coefficient with different normalized values of valve stem movement L/D and different pressure ratios of valve outlet and inlet agrees well with the ideal case and other similar previous experimental results. This study also provided a solid understanding with versatile options for analyzing the hydrodynamics of the combined valve considering the various internal geometry, seat, plug, and the inlet plus outlet boundary conditions to improve the efficiency, performance and reliability of the turbine system of small as well as large power conversion system using the numerical analysis with minimal cost and time

  1. Numerical Analysis of Combined Valve Hydrodynamic Characteristics for Turbine System

    Energy Technology Data Exchange (ETDEWEB)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Arif, M.; Suh, Kune Y. [Seoul National Univ., Seoul (Korea, Republic of)

    2014-05-15

    precisely by the valve manufacturer. As a matter of fact, attempts were made to obtain flow characteristic curves resorting to analytical as well as numerical methods. The flow characteristic curve relates the stem lift with mass flow rate at a specific temperature and pressure. This paper focuses on computational and numerical analysis of the combined stop and control valve. Combined Airflow Regulation Analysis (CARA) is performed to check on the hydrodynamic characteristic, which is represented by flow coefficient characteristic. CATIA V.5 and ANSYS CFX are used for three-dimensional computer-aided design and computational fluid dynamics (CFD) analysis, respectively. Flow characteristic curves are plotted by calculating theoretical and numerical mass flow rate. Hydrodynamic analysis was made of the combined stop and control valve for the turbine system using ANSYS CFX. The result of the numerical study represented by the valve flow coefficient with different normalized values of valve stem movement L/D and different pressure ratios of valve outlet and inlet agrees well with the ideal case and other similar previous experimental results. This study also provided a solid understanding with versatile options for analyzing the hydrodynamics of the combined valve considering the various internal geometry, seat, plug, and the inlet plus outlet boundary conditions to improve the efficiency, performance and reliability of the turbine system of small as well as large power conversion system using the numerical analysis with minimal cost and time.

  2. Developing a Cost Model and Methodology to Estimate Capital Costs for Thermal Energy Storage

    Energy Technology Data Exchange (ETDEWEB)

    Glatzmaier, G.

    2011-12-01

    system leads to higher thermal-to-electric conversion efficiency. However, in a CSP system, higher operating temperature also leads to greater thermal losses. These two effects combine to give an optimal system-level operating temperature that may be less than the upper operating temperature limit of system components. The overall efficiency may be improved by developing materials, power cycles, and system-integration strategies that enable operation at elevated temperature while limiting thermal losses. This is particularly true for the TES system and its components. Meeting the SunShot cost target will require cost and performance improvements in all systems and components within a CSP plant. Solar collector field hardware will need to decrease significantly in cost with no loss in performance and possibly with performance improvements. As higher temperatures are considered for the power block, new working fluids, heat-transfer fluids (HTFs), and storage fluids will all need to be identified to meet these new operating conditions. Figure 1 shows thermodynamic conversion efficiency as a function of temperature for the ideal Carnot cycle and 75% Carnot, which is considered to be the practical efficiency attainable by current power cycles. Current conversion efficiencies for the parabolic trough steam cycle, power tower steam cycle, parabolic dish/Stirling, Ericsson, and air-Brayton/steam Rankine combined cycles are shown at their corresponding operating temperatures. Efficiencies for supercritical steam and carbon dioxide (CO{sub 2}) are also shown for their operating temperature ranges.

  3. Open Architecture Data System for NASA Langley Combined Loads Test System

    Science.gov (United States)

    Lightfoot, Michael C.; Ambur, Damodar R.

    1998-01-01

    The Combined Loads Test System (COLTS) is a new structures test complex that is being developed at NASA Langley Research Center (LaRC) to test large curved panels and cylindrical shell structures. These structural components are representative of aircraft fuselage sections of subsonic and supersonic transport aircraft and cryogenic tank structures of reusable launch vehicles. Test structures are subjected to combined loading conditions that simulate realistic flight load conditions. The facility consists of two pressure-box test machines and one combined loads test machine. Each test machine possesses a unique set of requirements or research data acquisition and real-time data display. Given the complex nature of the mechanical and thermal loads to be applied to the various research test articles, each data system has been designed with connectivity attributes that support both data acquisition and data management functions. This paper addresses the research driven data acquisition requirements for each test machine and demonstrates how an open architecture data system design not only meets those needs but provides robust data sharing between data systems including the various control systems which apply spectra of mechanical and thermal loading profiles.

  4. Cost analysis on a continuously operated fine chemicals production plant at 10 kg/day using a combination of microprocessing and microwave heating

    NARCIS (Netherlands)

    Benaskar, F.; Ben-Abdelmoumen, A.; Patil, N.G.; Rebrov, E.; Meuldijk, J.; Hessel, V.; Hulshof, L.A.; Krtschil, U.; Schouten, J.C.

    2011-01-01

    An extended cost study consisting of 14 process scenarios was carried out to envisage the cost impact of microprocessing and microwaves separately or in combination for two liquid-phase model reactions in fine-chemicals synthesis: (1) Ullmann C–O cross-coupling reaction and (2) the aspirin

  5. A low-cost EDXRF analysis system

    International Nuclear Information System (INIS)

    Kahdeman, J.E.; Watson, W.

    1984-01-01

    The article deals with an EDXRF (Energy Dispersive X-ray Fluorescence) system, the Spectrace (sup TM) 4020 (Tractor X-ray). The Spectra analysis software is both powerful and flexible enough to handle a wide variety of applications. The instrument was designed to be economical by integrating the major system components into a single unit. This practical approach to hardware has cut the cost per unit. The software structure of the Spectra 4020 is presented in a flow chart. The article also contains a diagram of the hardware configuration of the instrument

  6. A database prototype has been developed to help understand costs in photovoltaic systems

    International Nuclear Information System (INIS)

    Moorw, Larry M.

    2000-01-01

    High photovoltaic (PV) system costs hinder market growth. An approach to studying these costs has been developed using a database containing system, component and maintenance information. This data, which is both technical and non-technical in nature, is to be used to identify trends related to costs. A pilot database exists at this time and work is continuing. The results of this work may be used by the data owners to improve their operations with the goal of sharing non-attributable information with the public and industry at large. The published objectives of the DOE PV program are to accelerate the development of PV as a national and global energy option, as well as ensure US technology and global market leadership. The approach to supporting these objectives is to understand what drives costs in PV applications. This paper and poster session describe work-in-progress in the form of a database that will help identify costs in PV systems. In an effort to address DOE's Five-Year PV Milestones, a program was established in the summer of 1999 to study system costs in three PV applications--solar home lighting, water pumping, and grid-tied systems. This work began with a RFQ requesting data from these types of systems. Creating a partnership with industry and other system organizations such as Non-Government Organizations (NGOs) was the approach chosen to maintain a close time to the systems in the field. Nine participants were selected as partners, who provided data on their systems. Two activities are emphasized in this work. For the first, an iterative approach of developing baseline reliability and costs information with the participants was taken. This effort led to identifying typical components in these systems as well as the specific data (metrics) that would be needed in any analysis used to understand total systems costs

  7. Preliminary cost analysis of a universal package concept in the spent fuel management system

    International Nuclear Information System (INIS)

    1984-09-01

    The purpose of this study is to provide a preliminary cost assessment of a universal spent fuel package concept as it applies to the backend of the once through nuclear fuel cycle; i.e., a package that would be qualified for spent fuel storage, transportation, and disposal. To provide this preliminary cost assessment, costs for each element of the spent fuel management system have been compiled for system scenarios employing the universal package, and these costs are compared against system costs for scenarios employing the universal package, and these costs are compared against system costs for scenarios employing other types of storage, transportation, and disposal packages. The system elements considered in this study are storage at the nuclear power plant, spent fuel transportation, a Monitored Retrievable Storage (MRS) facility, and a geologic repository. In accordance with the Nuclear Waste Policy Act, most of these system elements and associated functions will be the responsibility of the Department of Energy. 10 refs., 25 figs., 22 tabs

  8. Industrial cost assessment for ITER tritium plant system (water distillation, VPCE and ISS)

    International Nuclear Information System (INIS)

    Sood, S.K.; Kalyanam, K.M.; Fong, C.

    1995-01-01

    The objective of this Industrial Cost Assessment Task for ITER Tritium Plant System consists of providing and order of magnitude cost estimate for the following major subsystems, as outlined in the Scope of Task Agreement and Work Program: water distillation (WD) system, vapour phase catalytic exchange (VPCE) system and the isotope separation system (ISS). The methodology adopted in preparing the order of magnitude cost estimate for the above three subsystems of the ITER tritium plant system is based on building the estimate from the ground up, starting with equipment cost estimates, and adding labour activities separately for engineering, fabrication, assembly, testing installation commissioning, etc. The estimate has been developed assuming that the systems are to be engineered, fabricated and constructed in Canada, (to comply with the Codes, Standards, QA and Seismic Classification applicable in Canada) since information on ITER siting is not currently available. The estimate is based on Ontario Hydro in house cost data on similar systems and equipment, such as the heavy water upgrading plants. The cost estimates are not based on quotations from suppliers for specific ITER components, since this would require completion of detailed design and specifications. 4 refs., 9 tabs., 7 figs

  9. LOW COST SMART SOLAR POWERED AUTOMATIC IRRIGATION SYSTEM

    OpenAIRE

    Hinsermu Alemayehu*, Kena Likassa

    2016-01-01

    In developing countries Photovoltaic energy can find many applications in agriculture, providing electrical energy in various cases, particularly OFF grid and desert area. Today Modern irrigation methods in developing country are needed to fulfill the food demands. Although in these countries Ethiopia, there are many diesel engine operated and rare solar operated water pumps for irrigation; but due to the running cost of diesel and capital cost of photovoltaic irrigation system. So Photovolta...

  10. Cost-effectiveness analysis of a fixed-dose combination of indacaterol and glycopyrronium as maintenance treatment for COPD

    Directory of Open Access Journals (Sweden)

    Chan M

    2018-04-01

    Full Text Available Ming-Cheng Chan,1,* Elise Chia-Hui Tan,2 Ming-Chin Yang3,* 1Section of Chest Medicine, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung, Taiwan, Republic of China; 2National Research Institute of Chinese Medicine, Ministry of Health and Welfare, Taipei, Taiwan, Republic of China; 3Institute of Health Policy and Management, National Taiwan University, Taipei, Taiwan, Republic of China *These authors contributed equally to this work Objective: The aim of this study was to evaluate the cost-effectiveness of the long-acting beta-2 agonist (LABA/long-acting muscarinic antagonist (LAMA dual bronchodilator indacaterol/glycopyrronium (IND/GLY as a maintenance treatment for COPD patients from the perspective of health care payer in Taiwan. Patients and methods: We adopted a patient-level simulation model, which included a cohort of COPD patients aged ≥40 years. The intervention used in the study was the treatment using IND/GLY, and comparators were tiotropium or salmeterol/fluticasone combination (SFC. Data related to the efficacy of drugs, incidence of exacerbation, and utility were obtained from clinical studies. Direct costs were estimated from claims data based on the severity of COPD. The cycle length was 6 months (to match forced expiratory volume in 1 second [FEV1] data, and the time horizons included 1, 3, 5, 10 years, and lifetime. Deterministic and probabilistic sensitivity analyses were conducted to test the robustness of the model results. Costs were expressed in US dollars with a discount rate of 3.0%. Results: Compared to tiotropium and SFC, the incremental cost-effectiveness ratios (ICERs per quality-adjusted life year (QALY gained of patients treated with IND/GLY were US$5,987 and US$14,990, respectively. One-way sensitivity analysis revealed that the improvement in FEV1 provided by IND/GLY, the distribution of patients with regard to the severity of COPD, and acute exacerbation rate ratio were the key

  11. Thermodynamic performance analysis and optimization of a solar-assisted combined cooling, heating and power system

    International Nuclear Information System (INIS)

    Wang, Jiangjiang; Lu, Yanchao; Yang, Ying; Mao, Tianzhi

    2016-01-01

    This study aims to present a thermodynamic performance analysis and to optimize the configurations of a hybrid combined cooling, heating and power (CCHP) system incorporating solar energy and natural gas. A basic natural gas CCHP system containing a power generation unit, a heat recovery system, an absorption cooling system and a storage tank is integrated with solar photovoltaic (PV) panels and/or a heat collector. Based on thermodynamic modeling, the thermodynamic performance, including energy and exergy efficiencies, under variable work conditions, such as electric load factor, solar irradiance and installation ratio, of the solar PV panels and heat collector is investigated and analyzed. The results of the energy supply side analysis indicate that the integration of solar PV into the CCHP system more efficiently improves the exergy efficiency, whereas the integration of a solar heat collector improves the energy efficiency. To match the building loads, the optimization method combined with the operation strategy is employed to optimize the system configurations to maximize the integrated benefits of energy and economic costs. The optimization results of demand–supply matching demonstrate that the integration of a solar heat collector achieves a better integrated performance than the solar PV integration in the specific case study. - Highlights: • Design a CCHP system integrated with solar PV and heat collector. • Present the energy and exergy analyses under variable work conditions. • Propose an optimization method of CCHP system for demand-supply matching.

  12. Cost benefit analysis of instrumentation, supervision and control systems for nuclear power plants

    International Nuclear Information System (INIS)

    Hagen, P.

    1973-08-01

    A cost benefit analysis is carried out on a BWR type reactor power plant in which an on-line computer performs plant supervision, reporting, logging, calibration and control functions, using display devices and plotters, while an off-line computer is available for bigger jobs such as fuel management calculations. All on-line functions are briefly described and specified. Three types of computer system are considered, a simplex system, a dual computer system and a multi-processor system. These systems are analysed with respect to reliability, back-up instrumentation requirements and costs. While the multiprocessor system gave in all cases the lowest annual failure costs, the margin to the duplex system was so small that hardware, maintenance and software costs would play an important role in making a decision. (JIW)

  13. System Approach of Logistic Costs Optimization Solution in Supply Chain

    OpenAIRE

    Majerčák, Peter; Masárová, Gabriela; Buc, Daniel; Majerčáková, Eva

    2013-01-01

    This paper is focused on the possibility of using the costs simulation in supply chain, which are on relative high level. Our goal is to determine the costs using logistic costs optimization which must necessarily be used in business activities in the supply chain management. The paper emphasizes the need to perform not isolated optimization in the whole supply chain. Our goal is to compare classic approach, when every part tracks its costs isolated, a try to minimize them, with the system (l...

  14. Computer software to estimate timber harvesting system production, cost, and revenue

    Science.gov (United States)

    Dr. John E. Baumgras; Dr. Chris B. LeDoux

    1992-01-01

    Large variations in timber harvesting cost and revenue can result from the differences between harvesting systems, the variable attributes of harvesting sites and timber stands, or changing product markets. Consequently, system and site specific estimates of production rates and costs are required to improve estimates of harvesting revenue. This paper describes...

  15. Method for Controlling Space Transportation System Life Cycle Costs

    Science.gov (United States)

    McCleskey, Carey M.; Bartine, David E.

    2006-01-01

    A structured, disciplined methodology is required to control major cost-influencing metrics of space transportation systems during design and continuing through the test and operations phases. This paper proposes controlling key space system design metrics that specifically influence life cycle costs. These are inclusive of flight and ground operations, test, and manufacturing and infrastructure. The proposed technique builds on today's configuration and mass properties control techniques and takes on all the characteristics of a classical control system. While the paper does not lay out a complete math model, key elements of the proposed methodology are explored and explained with both historical and contemporary examples. Finally, the paper encourages modular design approaches and technology investments compatible with the proposed method.

  16. Space system production cost benefits from contemporary philosophies in management and manufacturing

    Science.gov (United States)

    Rosmait, Russell L.

    1991-01-01

    The cost of manufacturing space system hardware has always been expensive. The Engineering Cost Group of the Program Planning office at Marshall is attempting to account for cost savings that result from new technologies in manufacturing and management. The objective is to identify and define contemporary philosophies in manufacturing and management. The seven broad categories that make up the areas where technological advances can assist in reducing space system costs are illustrated. Included within these broad categories is a list of the processes or techniques that specifically provide the cost savings within todays design, test, production and operations environments. The processes and techniques listed achieve savings in the following manner: increased productivity; reduced down time; reduced scrap; reduced rework; reduced man hours; and reduced material costs. In addition, it should be noted that cost savings from production and processing improvements effect 20 to 40 pct. of production costs whereas savings from management improvements effects 60 to 80 of production cost. This is important because most efforts in reducing costs are spent trying to reduce cost in the production.

  17. System cost model user's manual, version 1.2

    International Nuclear Information System (INIS)

    Shropshire, D.

    1995-06-01

    The System Cost Model (SCM) was developed by Lockheed Martin Idaho Technologies in Idaho Falls, Idaho and MK-Environmental Services in San Francisco, California to support the Baseline Environmental Management Report sensitivity analysis for the U.S. Department of Energy (DOE). The SCM serves the needs of the entire DOE complex for treatment, storage, and disposal (TSD) of mixed low-level, low-level, and transuranic waste. The model can be used to evaluate total complex costs based on various configuration options or to evaluate site-specific options. The site-specific cost estimates are based on generic assumptions such as waste loads and densities, treatment processing schemes, existing facilities capacities and functions, storage and disposal requirements, schedules, and cost factors. The SCM allows customization of the data for detailed site-specific estimates. There are approximately forty TSD module designs that have been further customized to account for design differences for nonalpha, alpha, remote-handled, and transuranic wastes. The SCM generates cost profiles based on the model default parameters or customized user-defined input and also generates costs for transporting waste from generators to TSD sites

  18. A configurable electrical capacitance tomography system using a combining electrode strategy

    International Nuclear Information System (INIS)

    Yang, Yunjie; Peng, Lihui

    2013-01-01

    Systematic investigation of a combining electrode strategy for electrical capacitance tomography (ECT) is carried out. A configurable digital and analogue mixed ECT system using a combining electrode strategy is presented. Compared to the traditional ECT system, the presented system can be configured flexibly as the traditional ECT sensor mode and the combining electrode mode by connecting a number of electrodes as a combined electrode. In particular, the combining electrode mode is increasing the number of capacitance measurement data and the amelioration of sensitivity distribution. An image reconstruction framework is proposed by configuring the presented ECT system as the corresponding sensor mode adaptive to the permittivity distribution to be reconstructed, which includes the traditional ECT sensor mode, the symmetric combining electrode mode, the asymmetric combining electrode mode and the mixed combining electrode mode. Both simulation and experimental results show that image reconstructions with better quality and robustness to measurement noise can be obtained under the proposed adaptive image reconstruction framework by using the presented configurable ECT system. (paper)

  19. The health system burden of chronic disease care: an estimation of provider costs of selected chronic diseases in Uganda.

    Science.gov (United States)

    Settumba, Stella Nalukwago; Sweeney, Sedona; Seeley, Janet; Biraro, Samuel; Mutungi, Gerald; Munderi, Paula; Grosskurth, Heiner; Vassall, Anna

    2015-06-01

    To explore the chronic disease services in Uganda: their level of utilisation, the total service costs and unit costs per visit. Full financial and economic cost data were collected from 12 facilities in two districts, from the provider's perspective. A combination of ingredients-based and step-down allocation costing approaches was used. The diseases under study were diabetes, hypertension, chronic obstructive pulmonary disease (COPD), epilepsy and HIV infection. Data were collected through a review of facility records, direct observation and structured interviews with health workers. Provision of chronic care services was concentrated at higher-level facilities. Excluding drugs, the total costs for NCD care fell below 2% of total facility costs. Unit costs per visit varied widely, both across different levels of the health system, and between facilities of the same level. This variability was driven by differences in clinical and drug prescribing practices. Most patients reported directly to higher-level facilities, bypassing nearby peripheral facilities. NCD services in Uganda are underfunded particularly at peripheral facilities. There is a need to estimate the budget impact of improving NCD care and to standardise treatment guidelines. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  20. U.S. Solar Photovoltaic System Cost Benchmark: Q1 2017

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Ran [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Feldman, David J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Woodhouse, Michael A. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ardani, Kristen B. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-11

    NREL has been modeling U.S. photovoltaic (PV) system costs since 2009. This year, our report benchmarks costs of U.S. solar PV for residential, commercial, and utility-scale systems built in the first quarter of 2017 (Q1 2017). Costs are represented from the perspective of the developer/installer, thus all hardware costs represent the price at which components are purchased by the developer/installer, not accounting for preexisting supply agreements or other contracts. Importantly, the benchmark this year (2017) also represents the sales price paid to the installer; therefore, it includes profit in the cost of the hardware, along with the profit the installer/developer receives, as a separate cost category. However, it does not include any additional net profit, such as a developer fee or price gross-up, which are common in the marketplace. We adopt this approach owing to the wide variation in developer profits in all three sectors, where project pricing is highly dependent on region and project specifics such as local retail electricity rate structures, local rebate and incentive structures, competitive environment, and overall project or deal structures.

  1. Cost Study for Manufacturing of Solid Oxide Fuel Cell Power Systems

    Energy Technology Data Exchange (ETDEWEB)

    Weimar, Mark R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chick, Lawrence A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gotthold, David W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Whyatt, Greg A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-09-30

    Solid oxide fuel cell (SOFC) power systems can be designed to produce electricity from fossil fuels at extremely high net efficiencies, approaching 70%. However, in order to penetrate commercial markets to an extent that significantly impacts world fuel consumption, their cost will need to be competitive with alternative generating systems, such as gas turbines. This report discusses a cost model developed at PNNL to estimate the manufacturing cost of SOFC power systems sized for ground-based distributed generation. The power system design was developed at PNNL in a study on the feasibility of using SOFC power systems on more electric aircraft to replace the main engine-mounted electrical generators [Whyatt and Chick, 2012]. We chose to study that design because the projected efficiency was high (70%) and the generating capacity was suitable for ground-based distributed generation (270 kW).

  2. Combined emission economic dispatch of power system including solar photo voltaic generation

    International Nuclear Information System (INIS)

    Khan, Naveed Ahmed; Awan, Ahmed Bilal; Mahmood, Anzar; Razzaq, Sohail; Zafar, Adnan; Sidhu, Guftaar Ahmed Sardar

    2015-01-01

    Highlights: • Combined Emission Economic Dispatch Problem has been solved with inclusion of solar power plants. • Mixed Integer Optimization Problem has been solved using Particle Swarm Optimization. • Static and dynamic case studies have been considered. • Clouds effect with 15% and 30% reduced radiations has also been taken into account. • Simulation results prove the effectiveness of proposed model. - Abstract: Reliable and inexpensive electricity provision is one of the significant research objectives since decades. Various Economic Dispatch (ED) methods have been developed in order to address the challenge of continuous and sustainable electricity provision at optimized cost. Rapid escalation of fuel prices, depletion of fossil fuel reserves and environmental concerns have compelled us to incorporate the Renewable Energy (RE) resources in the energy mix. This paper presents Combined Emission Economic Dispatch (CEED) models developed for a system consisting of multiple Photo Voltaic (PV) plants and thermal units. Based on the nature of decision variables, our proposed model is essentially a Mixed Integer Optimization Problem (MIOP). Particle Swarm Optimization (PSO) is used to solve the optimization problem for a scenario involving six conventional and thirteen PV plants. Two test cases, Combined Static Emission Economic Dispatch (SCEED) and Combined Dynamic Emission Economic Dispatch (DCEED), have been considered. SCEED is performed for full solar radiation level as well as for reduced radiation level due to clouds effect. Simulation results have proved the effectiveness of the proposed model

  3. Cost estimation of a standalone photovoltaic power system in remote areas of Sarawak, Malaysia

    International Nuclear Information System (INIS)

    Jakhrani, A.Q.; Othman, A.K.; Rigit, A.R.H.; Samo, S.R.

    2012-01-01

    This paper aims to estimate the anticipated costs incurred from a standalone solar photovoltaic power system for the supply of electricity to the rural community in Sarawak, Malaysia. The life cycle cost analysis with net present value technique was employed for the evaluation of cost system. It was found that purchasing of solar photovoltaic components and the system installation cost will contribute 63% of the total investment and future anticipated costs will add to the remaining. Recurring cost will make 25% and components replacements 75% of future anticipated costs. It was discovered that the power generated from the solar photovoltaic system would be 38 times more expensive than electricity produced from the conventional sources. However, its installation in remote areas could be favourable where the grid-connected power supply is not accessible. (author)

  4. Examining the effectiveness of municipal solid waste management systems: An integrated cost-benefit analysis perspective with a financial cost modeling in Taiwan

    International Nuclear Information System (INIS)

    Weng, Yu-Chi; Fujiwara, Takeshi

    2011-01-01

    In order to develop a sound material-cycle society, cost-effective municipal solid waste (MSW) management systems are required for the municipalities in the context of the integrated accounting system for MSW management. Firstly, this paper attempts to establish an integrated cost-benefit analysis (CBA) framework for evaluating the effectiveness of MSW management systems. In this paper, detailed cost/benefit items due to waste problems are particularly clarified. The stakeholders of MSW management systems, including the decision-makers of the municipalities and the citizens, are expected to reconsider the waste problems in depth and thus take wise actions with the aid of the proposed CBA framework. Secondly, focusing on the financial cost, this study develops a generalized methodology to evaluate the financial cost-effectiveness of MSW management systems, simultaneously considering the treatment technological levels and policy effects. The impacts of the influencing factors on the annual total and average financial MSW operation and maintenance (O and M) costs are analyzed in the Taiwanese case study with a demonstrative short-term future projection of the financial costs under scenario analysis. The established methodology would contribute to the evaluation of the current policy measures and to the modification of the policy design for the municipalities.

  5. Examining the effectiveness of municipal solid waste management systems: an integrated cost-benefit analysis perspective with a financial cost modeling in Taiwan.

    Science.gov (United States)

    Weng, Yu-Chi; Fujiwara, Takeshi

    2011-06-01

    In order to develop a sound material-cycle society, cost-effective municipal solid waste (MSW) management systems are required for the municipalities in the context of the integrated accounting system for MSW management. Firstly, this paper attempts to establish an integrated cost-benefit analysis (CBA) framework for evaluating the effectiveness of MSW management systems. In this paper, detailed cost/benefit items due to waste problems are particularly clarified. The stakeholders of MSW management systems, including the decision-makers of the municipalities and the citizens, are expected to reconsider the waste problems in depth and thus take wise actions with the aid of the proposed CBA framework. Secondly, focusing on the financial cost, this study develops a generalized methodology to evaluate the financial cost-effectiveness of MSW management systems, simultaneously considering the treatment technological levels and policy effects. The impacts of the influencing factors on the annual total and average financial MSW operation and maintenance (O&M) costs are analyzed in the Taiwanese case study with a demonstrative short-term future projection of the financial costs under scenario analysis. The established methodology would contribute to the evaluation of the current policy measures and to the modification of the policy design for the municipalities. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  6. The System 80+ standard plant design reduces operations and maintenance costs

    International Nuclear Information System (INIS)

    Chari, D.R.; Robertson, J.E.

    1998-01-01

    To be cost-competitive, nuclear power plants must maximize plant availability and minimize operations and maintenance (O and M) costs. A plant whose design supports these goals will generate more power at less cost and thereby have a lower unit generating cost. The ABB Combustion Engineering Nuclear Systems (ABB-CE) System 80+ Standard Nuclear Power Plant, rated at 1400 megawatts electric (MWe), is designed for high availability at reduced cost. To demonstrate that the duration of refueling outages, the major contributor to plant unavailability, can be shortened, ABB-CE developed a detailed plan that shows a System 80+ plant can safely perform a refueling and maintenance outage in 18 days. This is a significant reduction from the average current U.S. plant outages of 45 days, and is possible due to a two-part outage strategy: use System 80+ advanced system design features and relaxed technical specification (TS) time limits to shift some maintenance from outages to operating periods: and, use System 80+ structural, system, and component features, such as the larger operating floor, permanent pool seal, integral reactor head area cable tray system and missile shield, and longer life reactor coolant pump seals, to reduce the scope and duration of outage maintenance activities. Plant staffing level is the major variable, or controllable contributor to operations costs. ABB-CE worked with the Institute of Nuclear Power Operations (INPO) to perform detailed staffing analyses that show a System 80+ plant can be operated reliably with 30 percent less staff than currently operating nuclear plants of similar size. Safety was not sacrificed when ABB-CE developed the System 80+ refueling outage plan and staffing level. The outage plan was developed utilizing a defense-in-depth concept for shutdown safety. The defense in-depth concept is implemented via systematic control of outage risk evaluation (SCORE) cards. The SCORE cards identify primary and alternate means of

  7. Solar PV Manufacturing Cost Model Group: Installed Solar PV System Prices (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Goodrich, A. C.; Woodhouse, M.; James, T.

    2011-02-01

    EERE's Solar Energy Technologies Program is charged with leading the Secretary's SunShot Initiative to reduce the cost of electricity from solar by 75% to be cost competitive with conventional energy sources without subsidy by the end of the decade. As part of this Initiative, the program has funded the National Renewable Energy Laboratory (NREL) to develop module manufacturing and solar PV system installation cost models to ensure that the program's cost reduction targets are carefully aligned with current and near term industry costs. The NREL cost analysis team has leveraged the laboratories' extensive experience in the areas of project finance and deployment, as well as industry partnerships, to develop cost models that mirror the project cost analysis tools used by project managers at leading U.S. installers. The cost models are constructed through a "bottoms-up" assessment of each major cost element, beginning with the system's bill of materials, labor requirements (type and hours) by component, site-specific charges, and soft costs. In addition to the relevant engineering, procurement, and construction costs, the models also consider all relevant costs to an installer, including labor burdens and overhead rates, supply chain costs, and overhead and materials inventory costs, and assume market-specific profits.

  8. Implementing a resident lifting system in an extended care hospital. Demonstrating cost-benefit.

    Science.gov (United States)

    Spiegel, Jerry; Yassi, Analee; Ronald, Lisa A; Tate, Robert B; Hacking, Penny; Colby, Teresa

    2002-03-01

    1. Implemeting mechanical resident lifting equipment in an extended care facility produced a payback from direct savings alone within 4 years. Payback occurred more quickly when the effect of indirect savings or the trend to rising compensation costs was considered. 2. Combining the observations of the occupational health nurses related to staff well being with relevant cost-benefit data is useful in influencing decision makers and in securing funding for prevention measures. 3. Clear identification of a viewpoint is an important part of an economic evaluation and cost-benefit analysis.

  9. Combined Optimal Control System for excavator electric drive

    Science.gov (United States)

    Kurochkin, N. S.; Kochetkov, V. P.; Platonova, E. V.; Glushkin, E. Y.; Dulesov, A. S.

    2018-03-01

    The article presents a synthesis of the combined optimal control algorithms of the AC drive rotation mechanism of the excavator. Synthesis of algorithms consists in the regulation of external coordinates - based on the theory of optimal systems and correction of the internal coordinates electric drive using the method "technical optimum". The research shows the advantage of optimal combined control systems for the electric rotary drive over classical systems of subordinate regulation. The paper presents a method for selecting the optimality criterion of coefficients to find the intersection of the range of permissible values of the coordinates of the control object. There is possibility of system settings by choosing the optimality criterion coefficients, which allows one to select the required characteristics of the drive: the dynamic moment (M) and the time of the transient process (tpp). Due to the use of combined optimal control systems, it was possible to significantly reduce the maximum value of the dynamic moment (M) and at the same time - reduce the transient time (tpp).

  10. Cost analysis of the development and implementation of a spatial decision support system for malaria elimination in Solomon Islands.

    Science.gov (United States)

    Marston, Luke; Kelly, Gerard C; Hale, Erick; Clements, Archie C A; Hodge, Andrew; Jimenez-Soto, Eliana

    2014-08-18

    The goal of malaria elimination faces numerous challenges. New tools are required to support the scale up of interventions and improve national malaria programme capacity to conduct detailed surveillance. This study investigates the cost factors influencing the development and implementation of a spatial decision support system (SDSS) for malaria elimination in the two elimination provinces of Isabel and Temotu, Solomon Islands. Financial and economic costs to develop and implement a SDSS were estimated using the Solomon Islands programme's financial records. Using an ingredients approach, verified by stakeholders and operational reports, total costs for each province were quantified. A budget impact sensitivity analysis was conducted to investigate the influence of variations in standard budgetary components on the costs and to identify potential cost savings. A total investment of US$ 96,046 (2012 constant dollars) was required to develop and implement the SDSS in two provinces (Temotu Province US$ 49,806 and Isabel Province US$ 46,240). The single largest expense category was for computerized equipment totalling approximately US$ 30,085. Geographical reconnaissance was the most expensive phase of development and implementation, accounting for approximately 62% of total costs. Sensitivity analysis identified different cost factors between the provinces. Reduced equipment costs would deliver a budget saving of approximately 10% in Isabel Province. Combined travel costs represented the greatest influence on the total budget in the more remote Temotu Province. This study provides the first cost analysis of an operational surveillance tool used specifically for malaria elimination in the South-West Pacific. It is demonstrated that the costs of such a decision support system are driven by specialized equipment and travel expenses. Such factors should be closely scrutinized in future programme budgets to ensure maximum efficiencies are gained and available resources

  11. [Financing, organization, costs and services performance of the Argentinean health sub-systems.

    Science.gov (United States)

    Yavich, Natalia; Báscolo, Ernesto Pablo; Haggerty, Jeannie

    2016-01-01

    To analyze the relationship between health system financing and services organization models with costs and health services performance in each of Rosario's health sub-systems. The financing and organization models were characterized using secondary data. Costs were calculated using the WHO/SHA methodology. Healthcare quality was measured by a household survey (n=822). Public subsystem:Vertically integrated funding and primary healthcare as a leading strategy to provide services produced low costs and individual-oriented healthcare but with weak accessibility conditions and comprehensiveness. Private subsystem: Contractual integration and weak regulatory and coordination mechanisms produced effects opposed to those of the public sub-system. Social security: Contractual integration and strong regulatory and coordination mechanisms contributed to intermediate costs and overall high performance. Each subsystem financing and services organization model had a strong and heterogeneous influence on costs and health services performance.

  12. Approximate ideal multi-objective solution Q(λ) learning for optimal carbon-energy combined-flow in multi-energy power systems

    International Nuclear Information System (INIS)

    Zhang, Xiaoshun; Yu, Tao; Yang, Bo; Zheng, Limin; Huang, Linni

    2015-01-01

    Highlights: • A novel optimal carbon-energy combined-flow (OCECF) model is firstly established. • A novel approximate ideal multi-objective solution Q(λ) learning is designed. • The proposed algorithm has a high convergence stability and reliability. • The proposed algorithm can be applied for OCECF in a large-scale power grid. - Abstract: This paper proposes a novel approximate ideal multi-objective solution Q(λ) learning for optimal carbon-energy combined-flow in multi-energy power systems. The carbon emissions, fuel cost, active power loss, voltage deviation and carbon emission loss are chosen as the optimization objectives, which are simultaneously optimized by five different Q-value matrices. The dynamic optimal weight of each objective is calculated online from the entire Q-value matrices such that the greedy action policy can be obtained. Case studies are carried out to evaluate the optimization performance for carbon-energy combined-flow in an IEEE 118-bus system and the regional power grid of southern China.

  13. Cost-benefit analysis for environmental impacts and radwaste system for nuclear power plant

    International Nuclear Information System (INIS)

    Mun, K.N.; Yook, C.C.

    1982-01-01

    During operation of nuclear power plant, radioactive material is inevitably formed. This radioactive material must be safely processed by radwaste system so that essentially zero activity is released to the environment. However zero released activity is not really practicable and population doses resulted from released activity are proportional to total annual cost for the radwaste system. In this study, cost-benefit analysis for the radwaste system of the Korean Nuclear Units 5 and 6 is performed to evaluate the optimization between the total annual cost for the radwaste system and population doses within 80 km from the plants. From the analysis, the following results are obtained; 1. the total population dose is estimated 4.04 x 10 3 man-rem/year, 2. total annual cost for the radwaste system is required $ 1.74 x 10 6 , 3. cost-benefit ratio is estimated $ 429/man-rem. (Author)

  14. Clinical Evaluation and Cost-Effectiveness Analysis of Serum Tumor Markers in Lung Cancer

    Directory of Open Access Journals (Sweden)

    Rong Wang

    2013-01-01

    Full Text Available The detection of serum tumor markers is valuable for the early diagnosis of lung cancer. Tumor markers are frequently used for the management of cancer patients. However, single markers are less efficient but marker combinations increase the cost, which is troublesome for clinics. To find an optimal serum marker combination panel that benefits the patients and the medical management system as well, four routine lung cancer serum markers (SCCA, NSE, CEA, and CYFRA21-1 were evaluated individually and in combination. Meanwhile, the costs and effects of these markers in clinical practice in China were assessed by cost-effectiveness analysis. As expected, combinations of these tumor markers improved their sensitivity for lung cancer and different combination panels had their own usefulness. NSE + CEA + CYFRA21-1 was the optimal combination panel with highest Youden’s index (0.64, higher sensitivity (75.76%, and specificity (88.57%, which can aid the clinical diagnosis of lung cancer. Nevertheless, the most cost-effective combination was SCCA + CEA, which can be used to screen the high-risk group.

  15. Performance and cost assessment of solar driven humidification dehumidification desalination system

    International Nuclear Information System (INIS)

    Zubair, M. Ifras; Al-Sulaiman, Fahad A.; Antar, M.A.; Al-Dini, Salem A.; Ibrahim, Nasiru I.

    2017-01-01

    Highlights: • Optimization of a new HDH system integrated solar evacuated tubes collectors was conducted. • The mathematical models developed for the collector and the HDH system were validated. • A multi-location analysis was then performed for six locations in Saudi Arabia. • Sharurah was found to have the highest annual output and Dhahran the lowest at 19,445 and 16,430 L. • The cost per liter of water produced varies from $0.032 to $0.038, depends on the location. - Abstract: A humidification-dehumidification (HDH) desalination system integrated with solar evacuated tubes was optimized. Then, the optimized system was assessed for the operation in different geographical locations, and the rate of freshwater production and cost per liter were determined in each location. The system design proposed in this paper uses a heat pipe design evacuated tube collector, which performs significantly better based on cost. An HDH desalination system with a closed-air/open-water loop, connected to the collector, was evaluated to determine the optimum operating parameters and the system performance during daytime (from 8 am to 3 pm), as well as the average day of each month for an entire year. The impact of the effectiveness of the humidifier and the dehumidifier, as well as, the number of collectors, were also studied. The analyses were performed for Dhahran, Jeddah, Riyadh, Sharurah, Qassim, and Tabuk to determine the effects of varying the geographical location. Sharurah has the highest calculated productivity of freshwater and Dhahran has the lowest at 19,445 and 16,430 L, respectively. To have a comprehensive study of the system proposed, a cost analysis was also performed to determine the feasibility of the system and the cost of water production. Results show that the price varied from $0.032 to $0.038 per liter for the locations evaluated.

  16. Highly integrated image sensors enable low-cost imaging systems

    Science.gov (United States)

    Gallagher, Paul K.; Lake, Don; Chalmers, David; Hurwitz, J. E. D.

    1997-09-01

    The highest barriers to wide scale implementation of vision systems have been cost. This is closely followed by the level of difficulty of putting a complete imaging system together. As anyone who has every been in the position of creating a vision system knows, the various bits and pieces supplied by the many vendors are not under any type of standardization control. In short, unless you are an expert in imaging, electrical interfacing, computers, digital signal processing, and high speed storage techniques, you will likely spend more money trying to do it yourself rather than to buy the exceedingly expensive systems available. Another alternative is making headway into the imaging market however. The growing investment in highly integrated CMOS based imagers is addressing both the cost and the system integration difficulties. This paper discusses the benefits gained from CMOS based imaging, and how these benefits are already being applied.

  17. A Transparent Framework for Evaluating the Effects of DGPV on Distribution System Costs

    Energy Technology Data Exchange (ETDEWEB)

    Horowitz, Kelsey A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Mather, Barry A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ding, Fei [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Denholm, Paul L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Palmintier, Bryan S [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-04-02

    Assessing the costs and benefits of distributed photovoltaic generators (DGPV) to the power system and electricity consumers is key to determining appropriate policies, tariff designs, and power system upgrades for the modern grid. We advance understanding of this topic by providing a transparent framework, terminology, and data set for evaluating distribution system upgrade costs, line losses, and interconnection costs as a function of DGPV penetration level.

  18. FlexSAR, a high quality, flexible, cost effective, prototype SAR system

    Science.gov (United States)

    Jensen, Mark; Knight, Chad; Haslem, Brent

    2016-05-01

    The FlexSAR radar system was designed to be a high quality, low-cost, flexible research prototype instrument. Radar researchers and practitioners often desire the ability to prototype new or advanced configurations, yet the ability to enhance or upgrade existing radar systems can be cost prohibitive. FlexSAR answers the need for a flexible radar system that can be extended easily, with minimal cost and time expenditures. The design approach focuses on reducing the resources required for developing and validating new advanced radar modalities. Such an approach fosters innovation and provides risk reduction since actual radar data can be collected in the appropriate mode, processed, and analyzed early in the development process. This allows for an accurate, detailed understanding of the corresponding trade space. This paper is a follow-on to last years paper and discusses the advancements that have been made to the FlexSAR system. The overall system architecture is discussed and presented along with several examples illustrating the system utility.

  19. Combinations of complex dynamical systems

    CERN Document Server

    Pilgrim, Kevin M

    2003-01-01

    This work is a research-level monograph whose goal is to develop a general combination, decomposition, and structure theory for branched coverings of the two-sphere to itself, regarded as the combinatorial and topological objects which arise in the classification of certain holomorphic dynamical systems on the Riemann sphere. It is intended for researchers interested in the classification of those complex one-dimensional dynamical systems which are in some loose sense tame. The program is motivated by the dictionary between the theories of iterated rational maps and Kleinian groups.

  20. Direct costs of emergency medical care: a diagnosis-based case-mix classification system.

    Science.gov (United States)

    Baraff, L J; Cameron, J M; Sekhon, R

    1991-01-01

    To develop a diagnosis-based case mix classification system for emergency department patient visits based on direct costs of care designed for an outpatient setting. Prospective provider time study with collection of financial data from each hospital's accounts receivable system and medical information, including discharge diagnosis, from hospital medical records. Three community hospital EDs in Los Angeles County during selected times in 1984. Only direct costs of care were included: health care provider time, ED management and clerical personnel excluding registration, nonlabor ED expense including supplies, and ancillary hospital services. Indirect costs for hospitals and physicians, including depreciation and amortization, debt service, utilities, malpractice insurance, administration, billing, registration, and medical records were not included. Costs were derived by valuing provider time based on a formula using annual income or salary and fringe benefits, productivity and direct care factors, and using hospital direct cost to charge ratios. Physician costs were based on a national study of emergency physician income and excluded practice costs. Patients were classified into one of 216 emergency department groups (EDGs) on the basis of the discharge diagnosis, patient disposition, age, and the presence of a limited number of physician procedures. Total mean direct costs ranged from $23 for follow-up visit to $936 for trauma, admitted, with critical care procedure. The mean total direct costs for the 16,771 nonadmitted patients was $69. Of this, 34% was for ED costs, 45% was for ancillary service costs, and 21% was for physician costs. The mean total direct costs for the 1,955 admitted patients was $259. Of this, 23% was for ED costs, 63% was for ancillary service costs, and 14% was for physician costs. Laboratory and radiographic services accounted for approximately 85% of all ancillary service costs and 38% of total direct costs for nonadmitted patients

  1. Analysis of the equilibrium trip cost accounting for the fuel cost in a single-lane traffic system without late arrival

    Science.gov (United States)

    Tang, Tie-Qiao; Wang, Tao; Chen, Liang; Huang, Hai-Jun

    2018-01-01

    In this paper, we introduce the fuel cost into each commuter's trip cost, define a new trip cost without late arrival and its corresponding equilibrium state, and use a car-following model to explore the impacts of the fuel cost on each commuter's departure time, departure interval, arrival time, arrival interval, traveling time, early arrival time and trip cost at the above equilibrium state. The numerical results show that considering the fuel cost in each commuter's trip cost has positive impacts on his trip cost and fuel cost, and the traffic situation in the system without late arrival, i.e., each commuter should explicitly consider the fuel cost in his trip cost.

  2. A cost-benefit analysis of bevacizumab in combination with paclitaxel in the first-line treatment of patients with metastatic breast cancer.

    Science.gov (United States)

    Montero, Alberto J; Avancha, Kiran; Glück, Stefan; Lopes, Gilberto

    2012-04-01

    Bevacizumab in combination with chemotherapy increases progression-free survival (PFS), but not overall survival when compared to chemotherapy alone in the treatment of metastatic breast cancer (MBC). Recently in November, 2011 the Food and drug administration revoked approval of bevacizumab in combination with paclitaxel for the treatment of MBC. The European Medicines Agency, in contrast, maintained its approval of bevacizumab in MBC. While neither agency considers health economics in their decision-making process, one of the greatest challenges in oncology practice today is to reconcile hard-won small incremental clinical benefits with exponentially rising costs. To inform policy-makers in the US, this study aimed to assess the cost-effectiveness of bevacizumab/paclitaxel in MBC, from a payer perspective. We created a decision analytical model using efficacy and adverse events data from the ECOG 2100 trial. Health utilities were derived from available literature. Costs were obtained from the Center for Medicare Services Drug Payment Table and Physician Fee Schedule and are represented in 2010 US dollars. Quality-adjusted life-years (QALY) and incremental cost-effectiveness ratio (ICER) were calculated. Sensitivity analyses were performed. Bevacizumab added 0.49 years of PFS and 0.135 QALY with an incremental cost of $100,300, and therefore a cost of $204,000 per year of PFS gained and an ICER of $745,000 per QALY. The main drivers of the model were drug acquisition cost, PFS, and health utility values. Using a threshold of $150,000/QALY, drug price would have to be reduced by nearly 80% or alternatively PFS increased by 10 months to make bevacizumab cost-effective. The results of the model were robust in sensitivity analyses. Bevacizumab plus paclitaxel is not cost-effective in treating MBC. Value-based pricing and the development of biomarkers to improve patient selection are needed to better define the role of the drug in this population.

  3. A HEDONIC APPROACH TO ESTIMATING OPERATION AND MAINTENANCE COSTS FOR NEW YORK MUNICIPAL WATER SYSTEMS

    OpenAIRE

    Schmit, Todd M.; Boisvert, Richard N.

    1997-01-01

    A hedonic cost function is used to isolate the operation and maintenance costs for water treatments. For small systems, costs are substantial for some technologies, but not for others. When regional differences in input costs are accounted for, small systems located in rural areas may have a cost advantage over similar systems closer to urban centers; however, costs of water treatment to meet Safe Drinking Water Act amendments may still be substantial.

  4. COST BENEFIT ANALYSIS OF A DG INTEGRATED SYSTEM: CASE STUDY

    Directory of Open Access Journals (Sweden)

    Ch. V. S. S. SAILAJA

    2017-09-01

    Full Text Available Distributed Generation is capable of meeting the load of the consumers partially or completely. Depending on the type of DG involved it can be operated in interconnected mode and islanded mode. The availability of numerous alternatives present for the DG technologies and large initial investments necessitates a detailed cost benefit analysis for the implementation of DG technologies. In this work an attempt has been made to study the costs involved in implementing the DG technologies. A practical system having two kinds of distributed generation i.e., Diesel Generator and solar photovoltaic system for its back up purpose is considered. A detailed cost analysis of the two DG technologies is carried out.

  5. Cost/schedule performance measurement system utilized on the Fast Flux Test Facility project

    International Nuclear Information System (INIS)

    Brown, R.K.; Frost, R.A.; Zimmerman, F.M.

    1976-01-01

    An Earned Value-Integrated Cost/Schedule Performance Measurement System has been applied to a major nonmilitary nuclear design and construction project. This system is similar to the Department of Defense Cost/Schedule Performance Measurement System. The project is the Fast Flux Test Facility (a Fuels and Materials test reactor for the Liquid Metal Fast Breeder Reactor Program) being built at the Hanford Engineering Development Laboratory, Richland, Washington, by Westinghouse Hanford Company for the U. S. Energy Research and Development Administration. Because the project was well into the construction phase when the Earned Value System was being considered, it was decided that the principles of DOD's Cost/Schedule Control System Criteria would be applied to the extent possible but no major changes in accounting practices or management systems were imposed. Implementation of this system enabled the following questions to be answered: For work performed, how do actual costs compare with the budget for that work. What is the impact of cost and schedule variances at an overall project level composed of different kinds of activities. Without the Earned Value system, these questions could be answered in a qualitative, subjective manner at best

  6. The Design and Implementation of a Low Cost and High Security Smart Home System Based on Wi-Fi and SSL Technologies

    Science.gov (United States)

    Xu, Chong-Yao; Zheng, Xin; Xiong, Xiao-Ming

    2017-02-01

    With the development of Internet of Things (IoT) and the popularity of intelligent mobile terminals, smart home system has come into people’s vision. However, due to the high cost, complex installation and inconvenience, as well as network security issues, smart home system has not been popularized. In this paper, combined with Wi-Fi technology, Android system, cloud server and SSL security protocol, a new set of smart home system is designed, with low cost, easy operation, high security and stability. The system consists of Wi-Fi smart node (WSN), Android client and cloud server. In order to reduce system cost and complexity of the installation, each Wi-Fi transceiver, appliance control logic and data conversion in the WSN is setup by a single chip. In addition, all the data of the WSN can be uploaded to the server through the home router, without having to transit through the gateway. All the appliance status information and environmental information are preserved in the cloud server. Furthermore, to ensure the security of information, the Secure Sockets Layer (SSL) protocol is used in the WSN communication with the server. What’s more, to improve the comfort and simplify the operation, Android client is designed with room pattern to control home appliances more realistic, and more convenient.

  7. Life cycle costing of waste management systems: Overview, calculation principles and case studies

    International Nuclear Information System (INIS)

    Martinez-Sanchez, Veronica; Kromann, Mikkel A.; Astrup, Thomas Fruergaard

    2015-01-01

    Highlights: • We propose a comprehensive model for cost assessment of waste management systems. • The model includes three types of LCC: Conventional, Environmental and Societal LCCs. • The applicability of the proposed model is tested with two case studies. - Abstract: This paper provides a detailed and comprehensive cost model for the economic assessment of solid waste management systems. The model was based on the principles of Life Cycle Costing (LCC) and followed a bottom-up calculation approach providing detailed cost items for all key technologies within modern waste systems. All technologies were defined per tonne of waste input, and each cost item within a technology was characterised by both a technical and an economic parameter (for example amount and cost of fuel related to waste collection), to ensure transparency, applicability and reproducibility. Cost items were classified as: (1) budget costs, (2) transfers (for example taxes, subsidies and fees) and (3) externality costs (for example damage or abatement costs related to emissions and disamenities). Technology costs were obtained as the sum of all cost items (of the same type) within a specific technology, while scenario costs were the sum of all technologies involved in a scenario. The cost model allows for the completion of three types of LCC: a Conventional LCC, for the assessment of financial costs, an Environmental LCC, for the assessment of financial costs whose results are complemented by a Life Cycle Assessment (LCA) for the same system, and a Societal LCC, for socio-economic assessments. Conventional and Environmental LCCs includes budget costs and transfers, while Societal LCCs includes budget and externality costs. Critical aspects were found in the existing literature regarding the cost assessment of waste management, namely system boundary equivalency, accounting for temporally distributed emissions and impacts, inclusions of transfers, the internalisation of environmental

  8. Life cycle costing of waste management systems: Overview, calculation principles and case studies

    Energy Technology Data Exchange (ETDEWEB)

    Martinez-Sanchez, Veronica, E-mail: vems@env.dtu.dk [Technical University of Denmark, Department of Environmental Engineering, Miljoevej, Building 113, 2800 Kgs. Lyngby (Denmark); Kromann, Mikkel A. [COWI A/S, Parallelvej 2, 2800 Kgs. Lyngby (Denmark); Astrup, Thomas Fruergaard [Technical University of Denmark, Department of Environmental Engineering, Miljoevej, Building 113, 2800 Kgs. Lyngby (Denmark)

    2015-02-15

    Highlights: • We propose a comprehensive model for cost assessment of waste management systems. • The model includes three types of LCC: Conventional, Environmental and Societal LCCs. • The applicability of the proposed model is tested with two case studies. - Abstract: This paper provides a detailed and comprehensive cost model for the economic assessment of solid waste management systems. The model was based on the principles of Life Cycle Costing (LCC) and followed a bottom-up calculation approach providing detailed cost items for all key technologies within modern waste systems. All technologies were defined per tonne of waste input, and each cost item within a technology was characterised by both a technical and an economic parameter (for example amount and cost of fuel related to waste collection), to ensure transparency, applicability and reproducibility. Cost items were classified as: (1) budget costs, (2) transfers (for example taxes, subsidies and fees) and (3) externality costs (for example damage or abatement costs related to emissions and disamenities). Technology costs were obtained as the sum of all cost items (of the same type) within a specific technology, while scenario costs were the sum of all technologies involved in a scenario. The cost model allows for the completion of three types of LCC: a Conventional LCC, for the assessment of financial costs, an Environmental LCC, for the assessment of financial costs whose results are complemented by a Life Cycle Assessment (LCA) for the same system, and a Societal LCC, for socio-economic assessments. Conventional and Environmental LCCs includes budget costs and transfers, while Societal LCCs includes budget and externality costs. Critical aspects were found in the existing literature regarding the cost assessment of waste management, namely system boundary equivalency, accounting for temporally distributed emissions and impacts, inclusions of transfers, the internalisation of environmental

  9. Development of low-cost high-performance multispectral camera system at Banpil

    Science.gov (United States)

    Oduor, Patrick; Mizuno, Genki; Olah, Robert; Dutta, Achyut K.

    2014-05-01

    Banpil Photonics (Banpil) has developed a low-cost high-performance multispectral camera system for Visible to Short- Wave Infrared (VIS-SWIR) imaging for the most demanding high-sensitivity and high-speed military, commercial and industrial applications. The 640x512 pixel InGaAs uncooled camera system is designed to provide a compact, smallform factor to within a cubic inch, high sensitivity needing less than 100 electrons, high dynamic range exceeding 190 dB, high-frame rates greater than 1000 frames per second (FPS) at full resolution, and low power consumption below 1W. This is practically all the feature benefits highly desirable in military imaging applications to expand deployment to every warfighter, while also maintaining a low-cost structure demanded for scaling into commercial markets. This paper describes Banpil's development of the camera system including the features of the image sensor with an innovation integrating advanced digital electronics functionality, which has made the confluence of high-performance capabilities on the same imaging platform practical at low cost. It discusses the strategies employed including innovations of the key components (e.g. focal plane array (FPA) and Read-Out Integrated Circuitry (ROIC)) within our control while maintaining a fabless model, and strategic collaboration with partners to attain additional cost reductions on optics, electronics, and packaging. We highlight the challenges and potential opportunities for further cost reductions to achieve a goal of a sub-$1000 uncooled high-performance camera system. Finally, a brief overview of emerging military, commercial and industrial applications that will benefit from this high performance imaging system and their forecast cost structure is presented.

  10. Life cycle costing of waste management systems: overview, calculation principles and case studies.

    Science.gov (United States)

    Martinez-Sanchez, Veronica; Kromann, Mikkel A; Astrup, Thomas Fruergaard

    2015-02-01

    This paper provides a detailed and comprehensive cost model for the economic assessment of solid waste management systems. The model was based on the principles of Life Cycle Costing (LCC) and followed a bottom-up calculation approach providing detailed cost items for all key technologies within modern waste systems. All technologies were defined per tonne of waste input, and each cost item within a technology was characterised by both a technical and an economic parameter (for example amount and cost of fuel related to waste collection), to ensure transparency, applicability and reproducibility. Cost items were classified as: (1) budget costs, (2) transfers (for example taxes, subsidies and fees) and (3) externality costs (for example damage or abatement costs related to emissions and disamenities). Technology costs were obtained as the sum of all cost items (of the same type) within a specific technology, while scenario costs were the sum of all technologies involved in a scenario. The cost model allows for the completion of three types of LCC: a Conventional LCC, for the assessment of financial costs, an Environmental LCC, for the assessment of financial costs whose results are complemented by a Life Cycle Assessment (LCA) for the same system, and a Societal LCC, for socio-economic assessments. Conventional and Environmental LCCs includes budget costs and transfers, while Societal LCCs includes budget and externality costs. Critical aspects were found in the existing literature regarding the cost assessment of waste management, namely system boundary equivalency, accounting for temporally distributed emissions and impacts, inclusions of transfers, the internalisation of environmental impacts and the coverage of shadow prices, and there was also significant confusion regarding terminology. The presented cost model was implemented in two case study scenarios assessing the costs involved in the source segregation of organic waste from 100,000 Danish households and

  11. Exergy and exergoeconomic analysis of a Compressed Air Energy Storage combined with a district energy system

    International Nuclear Information System (INIS)

    Bagdanavicius, Audrius; Jenkins, Nick

    2014-01-01

    Highlights: • CAES and CAES with thermal storage systems were investigated. • The potential for using heat generated during the compression stage was analysed. • CAES-TS has the potential to be used both as energy storage and heat source. • CAES-TS could be a useful tool for balancing overall energy demand and supply. - Abstract: The potential for using heat generated during the compression stage of a Compressed Air Energy Storage system was investigated using exergy and exergoeconomic analysis. Two Compressed Air Energy Storage systems were analysed: Compressed Air Energy Storage (CAES) and Compressed Air Energy Storage combined with Thermal Storage (CAES-TS) connected to a district heating network. The maximum output of the CAES was 100 MWe and the output of the CAES-TS was 100 MWe and 105 MWth. The study shows that 308 GW h/year of electricity and 466 GW h/year of fuel are used to generate 375 GW h/year of electricity. During the compression of air 289 GW h/year of heat is generated, which is wasted in the CAES and used for district heating in the CAES-TS system. Energy efficiency of the CAES system was around 48% and the efficiency of CAES-TS was 86%. Exergoeconomic analysis shows that the exergy cost of electricity generated in the CAES was 13.89 ¢/kW h, and the exergy cost of electricity generated in the CAES-TS was 11.20 ¢/kW h. The exergy cost of heat was 22.24 ¢/kW h in the CAES-TS system. The study shows that CAES-TS has the potential to be used both as energy storage and heat source and could be a useful tool for balancing overall energy demand and supply

  12. COSTS CALCULATION OF TARGET COSTING METHOD

    Directory of Open Access Journals (Sweden)

    Sebastian UNGUREANU

    2014-06-01

    Full Text Available Cost information system plays an important role in every organization in the decision making process. An important task of management is ensuring control of the operations, processes, sectors, and not ultimately on costs. Although in achieving the objectives of an organization compete more control systems (production control, quality control, etc., the cost information system is important because monitors results of the other. Detailed analysis of costs, production cost calculation, quantification of losses, estimate the work efficiency provides a solid basis for financial control. Knowledge of the costs is a decisive factor in taking decisions and planning future activities. Managers are concerned about the costs that will appear in the future, their level underpinning the supply and production decisions as well as price policy. An important factor is the efficiency of cost information system in such a way that the information provided by it may be useful for decisions and planning of the work.

  13. Cost-effective control policies for multi-echelon distribution systems

    NARCIS (Netherlands)

    Diks, E.B.; Kok, de A.G.

    1996-01-01

    In this paper we consider a divergent multi-echelon inventory system, e.g., a distribution system or a production system. At every stockpoint orders are placed periodically. The order arrives after a fixed lead time. At the end of each period linear costs may be incurred at each stockpoint for

  14. Cost/performance analysis of an induction linac driver system for inertial fusion

    International Nuclear Information System (INIS)

    Hovingh, J.; Brady, V.O.; Faltens, A.; Hoyer, E.H.; Lee, E.P.

    1986-01-01

    A linear induction accelerator that produces a beam of energetic (≅ 10 GeV) heavy (A ≅ 200) ions is a prime candidate as a driver for inertial fusion. Continuing developments is amorphous iron for use in accelerating modules represent a potentially large reduction in the driver cost and an increase in the driver efficiency. Additional insulator developments may also represent a potentially large reduction in the driver cost. The efficiency and cost of the induction linac system is discussed as a function of output energy and pulse repetition frequency for several beam charge states, numbers of beams and beam particle species. Accelerating modules and transport modules are described. Large cost leverage items are identified as a guide to future research activities and technology of development that can yield further substantial reductions in the accelerator system cost and improvement in the accelerator system efficiency

  15. Cost/performance analysis of an induction linac driver system for inertial fusion

    International Nuclear Information System (INIS)

    Hovingh, J.; Brady, V.O.; Faltens, A.; Hoyer, E.H.; Lee, E.P.

    1985-11-01

    A linear induction accelerator that produces a beam of energetic (approx. =10 GeV) heavy (CAapprox.200) ions is a prime candidate as a driver for inertial fusion. Continuing developments in amorphous iron for use in accelerating modules represent a potentially large reduction in the driver cost and an increase in the driver efficiency. Additional insulator developments may also represent a potentially large reduction in the driver cost. The efficiency and cost of the induction linac system is discussed as a function of output energy and pulse repetition frequency for several beam charge states, numbers of beams and beam particle species. Accelerating modules and transport modules will be described. Large cost leverage items will be identified as a guide to future research activities and technology of development that can yield further substantial reductions in the accelerator system cost and improvement in the accelerator system efficiency. 13 refs., 2 figs

  16. Activity-based costing for pathology examinations and comparison with the current pricing system in Turkey.

    Science.gov (United States)

    Ergün, Ferda A K; Ağirbaş, Ismail; Kuzu, Işınsu

    2013-01-01

    To demonstrate the real cost data of the pathology examinations by using the activity-based costing method and to contribute to the financial planning of the departments, health managers and also the social security institution. Forty-four examinations selected from the Healthcare Implementation Notification system list and performed at the Ankara University Faculty of Medicine Pathology Department during September 2010 were studied. The analysis and the real cost calculations were done according to the duration of the procedures. Calculated costs were compared with the Healthcare Implementation Notification system and Medicare price lists. The costs of the pathology tests listed within the same pricing levels in the Healthcare Implementation Notification system list showed great differences. The minimum and maximum costs in level 1, 2, 3, and 4 were 15,98-80,15 TL, 15,95-258,59 TL, 42,38- 236,87 TL, and 124,42-406,76 TL, respectively. Medicare price levels were more consistent with the real costs of the examinations compared to the Healthcare Implementation Notification system price list. The prices of the pathology examination listed at different levels in the Healthcare Implementation Notification system lists do not cover the real costs of the work done. The principal parameters of Activity-Based Costing system are more suitable for making the most realistic cost categorization. Although the prices could differ between countries, the Medicare system categories are more realistic than the Healthcare Implementation Notification system. The Healthcare Implementation Notification system list needs to be revised in order to reflect the real costs of the pathology examinations.

  17. Comparison Study of Electromagnet and Permanent Magnet Systems for an Accelerator Using Cost-Based Failure Modes and Effects Analysis

    International Nuclear Information System (INIS)

    Spencer, C

    2004-01-01

    The next generation of particle accelerators will be one-of-a-kind facilities, and to meet their luminosity goals they must have guaranteed availability over their several decade lifetimes. The Next Linear Collider (NLC) is one viable option for a 1 TeV electron-positron linear collider, it has an 85% overall availability goal. We previously showed how a traditional Failure Modes and Effects Analysis (FMEA) of a SLAC electromagnet leads to reliability-enhancing design changes. Traditional FMEA identifies failure modes with high risk but does not consider the consequences in terms of cost, which could lead to unnecessarily expensive components. We have used a new methodology, ''Life Cost-Based FMEA'', which measures risk of failure in terms of cost, in order to evaluate and compare two different technologies that might be used for the 8653 NLC magnets: electromagnets or permanent magnets. The availabilities for the two different types of magnet systems have been estimated using empirical data from SLAC's accelerator failure database plus expert opinion on permanent magnet failure modes and industry standard failure data. Labor and material costs to repair magnet failures are predicted using a Monte Carlo simulation of all possible magnet failures over a 30-year lifetime. Our goal is to maximize up-time of the NLC through magnet design improvements and the optimal combination of electromagnets and permanent magnets, while reducing magnet system lifecycle costs

  18. Nonrenewable Energy Cost and Greenhouse Gas Emissions of a “Pig-Biogas-Fish” System in China

    Directory of Open Access Journals (Sweden)

    Qing Yang

    2012-01-01

    Full Text Available The purpose of this study is to assess the energy savings and emission reductions of the present rural biogas system in China. The life cycle assessment (LCA method is used to analyze a “pig-biogas-fish” system in Jingzhou, Hubei Province, China. The nonrenewable energy cost and the greenhouse gas (GHG emissions of the system, including the pigsty, the biogas digester, and the fishpond, are taken into account. The border definition is standardized because of the utilization of the database in this paper. The results indicate that the nonrenewable energy consumption intensity of the “pig-biogas-fish” system is 0.60 MJ/MJ and the equivalent CO2 emission intensity is 0.05 kg CO2-eq/MJ. Compared with the conventional animal husbandry system, the “pig-biogas-fish” system shows high renewability and GHG reduction benefit, which indicates that the system is a scientific and environmentally friendly chain combining energy and ecology.

  19. Cost Optimal System Identification Experiment Design

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning

    A structural system identification experiment design method is formulated in the light of decision theory, structural reliability theory and optimization theory. The experiment design is based on a preposterior analysis, well-known from the classical decision theory. I.e. the decisions concerning...... reflecting the cost of the experiment and the value of obtained additional information. An example concerning design of an experiment for parametric identification of a single degree of freedom structural system shows the applicability of the experiment design method....... the experiment design are not based on obtained experimental data. Instead the decisions are based on the expected experimental data assumed to be obtained from the measurements, estimated based on prior information and engineering judgement. The design method provides a system identification experiment design...

  20. Systematic Approach to Better Understanding Integration Costs

    Energy Technology Data Exchange (ETDEWEB)

    Stark, Gregory B. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    This research presents a systematic approach to evaluating the costs of integrating new generation and operational procedures into an existing power system, and the methodology is independent of the type of change or nature of the generation. The work was commissioned by the U.S. Department of Energy and performed by the National Renewable Energy Laboratory to investigate three integration cost-related questions: (1) How does the addition of new generation affect a system's operational costs, (2) How do generation mix and operating parameters and procedures affect costs, and (3) How does the amount of variable generation (non-dispatchable wind and solar) impact the accuracy of natural gas orders? A detailed operational analysis was performed for seven sets of experiments: variable generation, large conventional generation, generation mix, gas prices, fast-start generation, self-scheduling, and gas supply constraints. For each experiment, four components of integration costs were examined: cycling costs, non-cycling VO&M costs, fuel costs, and reserves provisioning costs. The investigation was conducted with PLEXOS production cost modeling software utilizing an updated version of the Institute of Electrical and Electronics Engineers 118-bus test system overlaid with projected operating loads from the Western Electricity Coordinating Council for the Sacramento Municipal Utility District, Puget Sound Energy, and Public Service Colorado in the year 2020. The test system was selected in consultation with an industry-based technical review committee to be a reasonable approximation of an interconnection yet small enough to allow the research team to investigate a large number of scenarios and sensitivity combinations. The research should prove useful to market designers, regulators, utilities, and others who want to better understand how system changes can affect production costs.

  1. A low cost PSD-based monocular motion capture system

    Science.gov (United States)

    Ryu, Young Kee; Oh, Choonsuk

    2007-10-01

    This paper describes a monocular PSD-based motion capture sensor to employ with commercial video game systems such as Microsoft's XBOX and Sony's Playstation II. The system is compact, low-cost, and only requires a one-time calibration at the factory. The system includes a PSD(Position Sensitive Detector) and active infrared (IR) LED markers that are placed on the object to be tracked. The PSD sensor is placed in the focal plane of a wide-angle lens. The micro-controller calculates the 3D position of the markers using only the measured intensity and the 2D position on the PSD. A series of experiments were performed to evaluate the performance of our prototype system. From the experimental results we see that the proposed system has the advantages of the compact size, the low cost, the easy installation, and the high frame rates to be suitable for high speed motion tracking in games.

  2. Estimating the Effects of Module Area on Thin-Film Photovoltaic System Costs: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Horowitz, Kelsey A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Fu, Ran [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Silverman, Timothy J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Woodhouse, Michael A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sun, Xingshu [Purdue University; Alam, Muhammad A [Purdue University

    2018-03-29

    We investigate the potential effects of module area on the cost and performance of photovoltaic systems. Applying a bottom-up methodology, we analyzed the costs associated with thin-film modules and systems as a function of module area. We calculate a potential for savings of up to 0.10 dollars/W and 0.13 dollars/W in module manufacturing costs for CdTe and CIGS respectively, with large area modules. We also find that an additional 0.04 dollars/W savings in balance-of-systems costs may be achieved. Sensitivity of the dollar/W cost savings to module efficiency, manufacturing yield, and other parameters is presented. Lifetime energy yield must also be maintained to realize reductions in the levelized cost of energy; the effects of module size on energy yield for monolithic thin-film modules are not yet well understood. Finally, we discuss possible non-cost barriers to adoption of large area modules.

  3. Calculation of energy costs of composite biomass stirring at biogas stations

    Science.gov (United States)

    Suslov, D. Yu; Temnikov, D. O.

    2018-03-01

    The paper is devoted to the study of the equipment to produce biogas fuel from organic wastes. The bioreactor equipped with a combined stirring system ensuring mechanical and bubbling stirring is designed. The method of energy cost calculation of the combined stirring system with original design is suggested. The received expressions were used in the calculation of the stirring system installed in the 10 m3 bioreactor: power consumed by the mixer during the start-up period made Nz =9.03 kW, operating power of the mixer made NE =1.406 kW, compressor power for bubbling stirring made NC =18.5 kW. Taking into account the operating mode of single elements of the stirring system, the energy cost made 4.38% of the total energy received by the biogas station.

  4. HTGR molten salt sensible energy transmission and storage system design and costs

    International Nuclear Information System (INIS)

    1981-09-01

    This report, which was prepared for Gas-Cooled Reactor Associates by United Engineers and Constructors under Contract No. GCRA/UE and C 81-203, presents the design and cost for a molten salt Sensible Energy Transmission and Storage (SETS) System. Although the reference system for this study is sized to be compatible with an 1170 MW(t) HTGR Nuclear Heat Source, the results and conclusions should be generally applicable to most large scale molten salt energy transmission system applications. A preliminary conceptual design is presented and alternative configurations are discussed. The sensitivity of system costs to variations in important system parameters are also presented. Costs for a reference case conceptual design are reported in constant 1980 dollars and inflated 1995 dollars

  5. Information system technologies' role in augmenting dermatologists' knowledge of prescription medication costs.

    Science.gov (United States)

    DeMarco, Sebastian S; Paul, Ravi; Kilpatrick, Russell J

    2015-12-01

    Despite the recent rising costs of once affordable dermatologic prescription medications, a survey measuring dermatologists' attitudes, beliefs, and knowledge of the cost of drugs they commonly prescribe has not been conducted. Awareness of drug costs is hindered by a lack of access to data about the prices of medicines. No surveys of physicians have addressed this issue by proposing new information system technologies that augment prescription medication price transparency and measuring how receptive physicians are to using these novel solutions in their daily clinical practice. Our research aims to investigate these topics with a survey of physicians in dermatology. Members of the North Carolina Dermatology Association were contacted through their electronic mailing list and asked to take an online survey. The survey asked several questions about dermatologists' attitudes and beliefs about drug costs. To measure their knowledge of prescription medications, the National Average Drug Acquisition Cost was used as an authoritative price that was compared to the survey takers' price estimates of drugs commonly used in dermatology. Physicians' willingness to use four distinct information system technologies that increase drug price transparency was also assessed. Dermatologists believe drug costs are an important factor in patient care and believe access to price information would allow them to provide a higher quality of care. Dermatologists' knowledge of the costs of medicines they commonly prescribe is poor, but they want to utilize information system technologies that increase access to drug pricing information. There is an unmet demand for information system technologies which increase price transparency of medications in dermatology. Physicians and IT professionals have the opportunity to create novel information systems that can be utilized to help guide cost conscious clinical decision making. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. The importance of fixed costs in animal health systems.

    Science.gov (United States)

    Tisdell, C A; Adamson, D

    2017-04-01

    In this paper, the authors detail the structure and optimal management of health systems as influenced by the presence and level of fixed costs. Unlike variable costs, fixed costs cannot be altered, and are thus independent of the level of veterinary activity in the short run. Their importance is illustrated by using both single-period and multi-period models. It is shown that multi-stage veterinary decision-making can often be envisaged as a sequence of fixed-cost problems. In general, it becomes clear that, the higher the fixed costs, the greater the net benefit of veterinary activity must be, if such activity is to be economic. The authors also assess the extent to which it pays to reduce fixed costs and to try to compensate for this by increasing variable costs. Fixed costs have major implications for the industrial structure of the animal health products industry and for the structure of the private veterinary services industry. In the former, they favour market concentration and specialisation in the supply of products. In the latter, they foster increased specialisation. While cooperation by individual farmers may help to reduce their individual fixed costs, the organisational difficulties and costs involved in achieving this cooperation can be formidable. In such cases, the only solution is government provision of veterinary services. Moreover, international cooperation may be called for. Fixed costs also influence the nature of the provision of veterinary education.

  7. Cost and performance analysis of physical protection systems - a case study

    International Nuclear Information System (INIS)

    Hicks, M.J.; Snell, M.S.; Sandoval, J.S.; Potter, C.S.

    1998-01-01

    Design and analysis of physical protection systems requires (1) identification of mission critical assets; (2) identification of potential threats that might undermine mission capability; (3) identification of the consequences of loss of mission-critical assets (e.g., time and cost to recover required capability and impact on operational readiness); and (4) analysis of the effectiveness of physical protection elements. CPA -- Cost and Performance Analysis -- addresses the fourth of these four issues. CPA is a methodology that joins Activity Based Cost estimation with performance-based analysis of physical protection systems. CPA offers system managers an approach that supports both tactical decision making and strategic planning. Current exploratory applications of the CPA methodology address analysis of alternative conceptual designs. Hypothetical data is used to illustrate this process

  8. Performance Evaluation of the Combined Agent Fire Fighting System (CAFFS)

    National Research Council Canada - National Science Library

    Kalberer, Jennifer

    2003-01-01

    ... of the location. The Combined Agent Fire Fighting System (CAFFS) employs innovations in nozzle design, lightweight composites and combination agents to design a system with extinguishment capabilities of much larger ARFF vehicles...

  9. Low-cost storage options for solar hydrogen systems for remote area power supply

    International Nuclear Information System (INIS)

    Suhaib Muhammad Ali; John Andrews

    2006-01-01

    Equipment for storing hydrogen gas under pressure typically accounts for a significant proportion of the total capital cost of solar-hydrogen systems for remote area power supply (RAPS). RAPS remain a potential early market for renewable energy - hydrogen systems because of the relatively high costs of conventional energy sources in remote regions. In the present paper the storage requirements of PV-based solar-hydrogen RAPS systems employing PEM electrolysers and fuel cells to meet a range of typical remote area daily and annual demand profiles are investigated using a spread sheet-based simulation model. It is found that as the costs of storage are lowered the requirement for longer-term storage from summer to winter is increased with consequent potential gains in the overall economics of the solar-hydrogen system. In many remote applications, there is ample space for hydrogen storages with relatively large volumes. Hence it may be most cost-effective to store hydrogen at low to medium pressures achievable by using PEM electrolysers directly to generate the hydrogen at the pressures required, without a requirement for separate electrically-driven compressors. The latter add to system costs while requiring significant parasitic electricity consumption. Experimental investigations into a number of low-cost storage options including plastic tanks and low-to-medium pressure metal and composite cylinders are reported. On the basis of these findings, the economics of solar-hydrogen RAPS systems employing large-volume low-cost storage are investigated. (authors)

  10. Low cost and open source multi-fluorescence imaging system for teaching and research in biology and bioengineering.

    Directory of Open Access Journals (Sweden)

    Isaac Nuñez

    Full Text Available The advent of easy-to-use open source microcontrollers, off-the-shelf electronics and customizable manufacturing technologies has facilitated the development of inexpensive scientific devices and laboratory equipment. In this study, we describe an imaging system that integrates low-cost and open-source hardware, software and genetic resources. The multi-fluorescence imaging system consists of readily available 470 nm LEDs, a Raspberry Pi camera and a set of filters made with low cost acrylics. This device allows imaging in scales ranging from single colonies to entire plates. We developed a set of genetic components (e.g. promoters, coding sequences, terminators and vectors following the standard framework of Golden Gate, which allowed the fabrication of genetic constructs in a combinatorial, low cost and robust manner. In order to provide simultaneous imaging of multiple wavelength signals, we screened a series of long stokes shift fluorescent proteins that could be combined with cyan/green fluorescent proteins. We found CyOFP1, mBeRFP and sfGFP to be the most compatible set for 3-channel fluorescent imaging. We developed open source Python code to operate the hardware to run time-lapse experiments with automated control of illumination and camera and a Python module to analyze data and extract meaningful biological information. To demonstrate the potential application of this integral system, we tested its performance on a diverse range of imaging assays often used in disciplines such as microbial ecology, microbiology and synthetic biology. We also assessed its potential use in a high school environment to teach biology, hardware design, optics, and programming. Together, these results demonstrate the successful integration of open source hardware, software, genetic resources and customizable manufacturing to obtain a powerful, low cost and robust system for education, scientific research and bioengineering. All the resources developed here

  11. Low cost and open source multi-fluorescence imaging system for teaching and research in biology and bioengineering.

    Science.gov (United States)

    Nuñez, Isaac; Matute, Tamara; Herrera, Roberto; Keymer, Juan; Marzullo, Timothy; Rudge, Timothy; Federici, Fernán

    2017-01-01

    The advent of easy-to-use open source microcontrollers, off-the-shelf electronics and customizable manufacturing technologies has facilitated the development of inexpensive scientific devices and laboratory equipment. In this study, we describe an imaging system that integrates low-cost and open-source hardware, software and genetic resources. The multi-fluorescence imaging system consists of readily available 470 nm LEDs, a Raspberry Pi camera and a set of filters made with low cost acrylics. This device allows imaging in scales ranging from single colonies to entire plates. We developed a set of genetic components (e.g. promoters, coding sequences, terminators) and vectors following the standard framework of Golden Gate, which allowed the fabrication of genetic constructs in a combinatorial, low cost and robust manner. In order to provide simultaneous imaging of multiple wavelength signals, we screened a series of long stokes shift fluorescent proteins that could be combined with cyan/green fluorescent proteins. We found CyOFP1, mBeRFP and sfGFP to be the most compatible set for 3-channel fluorescent imaging. We developed open source Python code to operate the hardware to run time-lapse experiments with automated control of illumination and camera and a Python module to analyze data and extract meaningful biological information. To demonstrate the potential application of this integral system, we tested its performance on a diverse range of imaging assays often used in disciplines such as microbial ecology, microbiology and synthetic biology. We also assessed its potential use in a high school environment to teach biology, hardware design, optics, and programming. Together, these results demonstrate the successful integration of open source hardware, software, genetic resources and customizable manufacturing to obtain a powerful, low cost and robust system for education, scientific research and bioengineering. All the resources developed here are available under

  12. Space Transportation System Availability Relationships to Life Cycle Cost

    Science.gov (United States)

    Rhodes, Russel E.; Donahue, Benjamin B.; Chen, Timothy T.

    2009-01-01

    Future space transportation architectures and designs must be affordable. Consequently, their Life Cycle Cost (LCC) must be controlled. For the LCC to be controlled, it is necessary to identify all the requirements and elements of the architecture at the beginning of the concept phase. Controlling LCC requires the establishment of the major operational cost drivers. Two of these major cost drivers are reliability and maintainability, in other words, the system's availability (responsiveness). Potential reasons that may drive the inherent availability requirement are the need to control the number of unique parts and the spare parts required to support the transportation system's operation. For more typical space transportation systems used to place satellites in space, the productivity of the system will drive the launch cost. This system productivity is the resultant output of the system availability. Availability is equal to the mean uptime divided by the sum of the mean uptime plus the mean downtime. Since many operational factors cannot be projected early in the definition phase, the focus will be on inherent availability which is equal to the mean time between a failure (MTBF) divided by the MTBF plus the mean time to repair (MTTR) the system. The MTBF is a function of reliability or the expected frequency of failures. When the system experiences failures the result is added operational flow time, parts consumption, and increased labor with an impact to responsiveness resulting in increased LCC. The other function of availability is the MTTR, or maintainability. In other words, how accessible is the failed hardware that requires replacement and what operational functions are required before and after change-out to make the system operable. This paper will describe how the MTTR can be equated to additional labor, additional operational flow time, and additional structural access capability, all of which drive up the LCC. A methodology will be presented that

  13. COST EVALUATION OF AUTOMATED AND MANUAL POST- CONSUMER PLASTIC BOTTLE SORTING SYSTEMS

    Science.gov (United States)

    This project evaluates, on the basis of performance and cost, two Automated BottleSort® sorting systems for post-consumer commingled plastic containers developed by Magnetic Separation Systems. This study compares the costs to sort mixed bales of post-consumer plastic at these t...

  14. Managerial accounting of costs in the system of management of enterprise logistics activity

    Directory of Open Access Journals (Sweden)

    L.G. Medvid

    2017-12-01

    Full Text Available The article deals with the analysis of scientific researches about the reflection of the logistics activity costs of a production enterprise in the system of analytical accounting. Practice shows that it is difficult to separate the reflection of logistics costs in primary documents in the system of financial accounting, and, as a result, the reflection in managerial reporting and the possibility of control and optimization. The research allows to determine the components of the organizational and methodical model of accounting of logistics costs according to the responsibility centers of production enterprises, namely, the system of responsibility centers according to the enterprise logistics activity, regulated documents, the system of budgetary logistics costs and internal managerial reporting according to the responsibility centers of the second level. This allowed to develop the methodological and organizational bases of managerial accounting of logistics activity costs of a productive enterprise.

  15. Cost reduction through combined solutions?; Kostensenkung durch Kombinationsloesungen?

    Energy Technology Data Exchange (ETDEWEB)

    Bilitewski, B. [Technische Univ. Dresden (Germany). Inst. fuer Abfallwirtschaft und Altlasten

    1998-09-01

    The implementation of material-specific residue treatment processes requires reconstruction measures both in the case of mechanical-biological and in that of thermal treatment plants. Such measures involves great uncertainties and wide variation in cost prediction. The present paper deals with various factors that influence the costs of residual waste treatment. [Deutsch] Zur Umsetzung der stoffspezifischen Restabfallbehandlung sind Anpassungen sowohl der derzeit betriebenen mechanisch-biologischen als auch der thermischen Anlagen erforderlich, was zu Unsicherheiten und grossen Schwankungsbreiten bei den Kostenprognosen fuehrt. Der Bericht beleuchtet verschiedene Einflussgroessen auf die Kosten der Behandlung des Restabfalls. (orig./SR)

  16. 42 CFR 412.6 - Cost reporting periods subject to the prospective payment systems.

    Science.gov (United States)

    2010-10-01

    ... payment systems. 412.6 Section 412.6 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES... prospective payment system for inpatient operating costs, the reasonable costs of services furnished before...

  17. Solar-assisted heat pump system for cost-effective space heating and cooling

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J W; Kush, E A; Metz, P D

    1978-03-01

    The use of heat pumps for the utilization of solar energy is studied. Two requirements for a cost-effective system are identified: (1) a special heat pump whose coefficient of performance continues to rise with source temperature over the entire range appropriate for solar assist, and (2) a low-cost collection and storage subsystem able to supply solar energy to the heat pump efficiently at low temperatures. Programs leading to the development of these components are discussed. A solar assisted heat pump system using these components is simulated via a computer, and the results of the simulation are used as the basis for a cost comparison of the proposed system with other solar and conventional systems.

  18. System of Indicators of the Level of Costs of Financing an Economic Subject

    Directory of Open Access Journals (Sweden)

    Laktionova Aleksandra A.

    2013-11-01

    Full Text Available The article offers a system of indicators of the level of costs of financing economic subjects, in the basis of which there is a function of formation of recommendations or identification of directions and priorities in the part of selection of one or another source of financing, its urgency and specific features of attraction of resources, on the basis of information on the level of agent’s costs, information asymmetry costs, financial instability, transaction and market indicators of cost of financial resources. The article pays a special attention to a significant structure forming factor of the ownership structure, which identifies the volume and logic of interconnection of all costs of financing and determining incentives and risks in the system of management of financial activity of an economic subject from the point of view of all participants. It exerts especially big influence upon formation of such implicit costs of financing as agent’s costs and information asymmetry costs. The system of factors of stimulants and de-stimulants of costs of financing includes factors of external environment (macro-economic and market indicators of cost and institutional provision and internal environment (ownership structure, characteristic of investment activity and financing an economic subject, organisation of business and corporate management.

  19. Process Simulation and Cost Analysis for Removing Inorganics from Wood Chips using Combined Mechanical and Chemical Preprocessing

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Hongqiang; Westover, Tyler L.; Cherry, Robert; Aston, John E.; Lacey, Jeffrey A.; Thompson, David N.

    2016-10-01

    Naturally occurring and introduced inorganic species (ash) in biomass feedstocks negatively impact thermochemical energy conversion processes such as pyrolysis, hydrothermal liquefaction, gasification and combustion to biopower. As such, it is desirable to better understand the cost:benefit ratios of various ash reduction processes. Here, a novel process simulation model was developed using AspenPlus to reduce the ash content of Loblolly logging residues using both air classification and a dilute-acid leaching process. For costing purposes, a throughput of 25 tons/hour was selected. At this scale, the process cost for a standalone air classification process was $3 per ton for a biomass feedstock. Ash reduction via dilute –acid leaching was simulated based on experimentally determined kinetics of ion diffusion at an acid concentration of 0.5% H2SO4 and temperature of 75°F. The total estimated processing cost for leaching at these conditions was approximately $14/ton of dry biomass. Sensitivity analysis of three parameters on mineral reduction in the leaching process revealed that increasing leaching temperature was not economically feasible, while it was viable to apply a longer retention time in leaching for higher ash removal or achieve a lower water content in final products with reasonable extra costs. In addition, scenarios combining air classification with leaching were examined. A whole process cost of approximately $16/ton of biomass at a biomass feedstock rate of 25 ton/hour considering a 9% of biomass classified as light fraction to be leached. The leaching operating costs constituted 75% of this amount, of which the heating costs of dryer was 44%. This suggests that the process costs would be substantially reduced if more efficient drying methods are applied in future.

  20. Guaranteed Cost Finite-Time Control of Fractional-Order Positive Switched Systems

    Directory of Open Access Journals (Sweden)

    Leipo Liu

    2017-01-01

    Full Text Available The problem of guaranteed cost finite-time control of fractional-order positive switched systems (FOPSS is considered in this paper. Firstly, a new cost function is defined. Then, by constructing linear copositive Lyapunov functions and using the average dwell time (ADT approach, a state feedback controller and a static output feedback controller are constructed, respectively, and sufficient conditions are derived to guarantee that the corresponding closed-loop systems are guaranteed cost finite-time stable (GCFTS. Such conditions can be easily solved by linear programming. Finally, two examples are given to illustrate the effectiveness of the proposed method.