WorldWideScience

Sample records for corpectomy sagittal alignment

  1. Sagittal Alignment of a Strut Graft Affects Graft Subsidence and Clinical Outcomes of Anterior Cervical Corpectomy and Fusion.

    Science.gov (United States)

    Yamauchi, Koun; Fushimi, Kazunari; Miyamoto, Kei; Hioki, Akira; Shimizu, Katsuji; Akiyama, Haruhiko

    2017-10-01

    Retrospective study. The purpose of this study was to investigate the influence of sagittal alignment of the strut graft on graft subsidence and clinical outcomes after anterior cervical corpectomy and fusion (ACCF). ACCF is a common technique for the treatment of various cervical pathologies. Although graft subsidence sometimes occurs after ACCF, it is one cause for poor clinical results. Malalignment of the strut graft is probably one of the factors associated with graft subsidence. However, to the best of our knowledge, no prior reports have demonstrated correlations between the alignment of the strut graft and clinical outcomes. We evaluated 56 patients (33 men and 23 women; mean age, 59 years; range, 33-84 years; 45 with cervical spondylotic myelopathy and 11 with ossification of the posterior longitudinal ligament) who underwent one- or two-level ACCF with an autogenous fibular strut graft and anterior plating. The Japanese Orthopaedic Association (JOA) score recovery ratio for cervical spondylotic myelopathy was used to evaluate clinical outcomes. The JOA score and lateral radiograms were evaluated 1 week and 1 year postoperatively. Patients were divided into two groups (a straight group [group I] and an oblique group [group Z]) based on radiographic assessment of the sagittal alignment of the strut graft. Group I showed a significantly greater JOA score recovery ratio ( p subsidence than group Z ( p subsidence after ACCF. In contrast, an oblique strut graft can lead to significantly increased strut graft subsidence and poor clinical results.

  2. FUNCTIONAL DISABILITY, SAGITTAL ALIGNMENT AND PELVIC BALANCE IN LUMBAR SPONDYLOLISTHESIS

    Directory of Open Access Journals (Sweden)

    Luis Muñiz Luna

    2016-03-01

    Full Text Available ABSTRACT Objectives: To demonstrate the recovery of lumbar sagittal pelvic alignment and sagittal pelvic balance after surgical reduction of lumbar spondylolisthesis and establish the benefits of the surgery for reduction and fixation of the lumbar spondylolisthesis with 360o circumferential arthrodesis for 2 surgical approaches by clinical and functional evaluation. Method: Eight patients with lumbar spondylolisthesis treated with surgical reduction and fixation of listhesis and segmental circumferential fusion with two surgical approaches were reviewed. They were evaluated before and after treatment with Oswestry, Visual Analogue for pain and Odom scales, performing radiographic measurement of lumbar sagittal alignment and pelvic sagittal balance with the technique of pelvic radius. Results: Oswestry scales and EVA reported improvement of symptoms after treatment in 8 cases; the Odom scale had six outstanding cases reported. The lumbar sagittal alignment presented a lumbosacral lordosis angle and a lumbopelvic lordosis angle reduced in 4 cases and increased in 4 other cases; pelvic sagittal balance increased the pelvic angle in 4 cases and decreased in 3 cases and the sacral translation of the hip axis to the promontory increased in 6 cases. Conclusion: The surgical procedure evaluated proved to be useful by modifying the lumbar sagittal alignment and the pelvic balance, besides reducing the symptoms, enabling the patient to have mobility and movement and the consequent satisfaction with the surgery.

  3. Relationship between screw sagittal angle and stress on endplate of adjacent segments after anterior cervical corpectomy and fusion with internal fixation: a Chinese finite element study.

    Science.gov (United States)

    Zhang, Yu; Tang, Yibo; Shen, Hongxing

    2017-12-01

    In order to reduce the incidence of adjacent segment disease (ASD), the current study was designed to establish Chinese finite element models of normal 3rd~7th cervical vertebrae (C3-C7) and anterior cervical corpectomy and fusion (ACCF) with internal fixation , and analyze the influence of screw sagittal angle (SSA) on stress on endplate of adjacent cervical segments. Mimics 8.1 and Abaqus/CAE 6.10 softwares were adopted to establish finite element models. For C4 superior endplate and C6 inferior endplate, their anterior areas had the maximum stress in anteflexion position, and their posterior areas had the maximum stress in posterior extension position. As SSA increased, the stress reduced. With an increase of 10° in SSA, the stress on anterior areas of C4 superior endplate and C6 inferior endplate reduced by 12.67% and 7.99% in anteflexion position, respectively. With an increase of 10° in SSA, the stress on posterior areas of C4 superior endplate and C6 inferior endplate reduced by 9.68% and 10.22% in posterior extension position, respectively. The current study established Chinese finite element models of normal C3-C7 and ACCF with internal fixation , and demonstrated that as SSA increased, the stress on endplate of adjacent cervical segments decreased. In clinical surgery, increased SSA is able to play important role in protecting the adjacent cervical segments and reducing the incidence of ASD.

  4. Lumbosacral sagittal alignment in association to intervertebral disc diseases.

    Science.gov (United States)

    Habibi, Zohreh; Maleki, Farid; Meybodi, Ali Tayebi; Mahdavi, Ali; Saberi, Hooshang

    2014-12-01

    A cross-sectional case-control study was designed to compare the sagittal alignment of lumbosacral regions in two groups of patients suffering from low back pain, one with intervertebral disc pathologies and one without. To evaluate the correlation between lumbosacral sagittal alignment and disc degeneration. Changes in lumbar lordosis and pelvic parameters in degenerative disc lesions have been assessed in few studies. Overall, patients with discopathy were shown to have lower lumbar lordosis and more vertical sacral profiles. From patients with intractable low back pain undergoing lumbosacral magnetic resonance imaging, 50 subjects with disc degeneration and 50 controls with normal scans were consecutively enrolled. A method was defined with anterior tangent-lines going through anterior bodies of L1 and S1 to measure global lumbosacral angle, incorporating both lumbar lordosis and sacral slope. Global lumbosacral angle using the proposed method and lumbar lordosis using Cobb's method were measured in both groups. Lumbar lordosis based on Cobb's method was lower in group with discopathy (20°-67°; mean, 40.48°±9.89°) than control group (30°-62°; mean, 44.96°±7.68°), although it was not statistically significant. The proposed global lumbosacral angle in subject group (53°-103°; mean, 76.5°±11.018°) was less than control group (52°-101°; mean, 80.18°±9.95°), with the difference being statistically significant (p=0.002). Patients with intervertebral disc lesions seem to have more straightened lumbosacral profiles, but it has not been proven which comes first: disc degeneration or changes in sagittal alignment. Finding an answer to this dilemma demands more comprehensive long-term prospective studies.

  5. Effect of posterior subsidence on cervical alignment after anterior cervical corpectomy and reconstruction using titanium mesh cages in degenerative cervical disease.

    Science.gov (United States)

    Jang, Jae-Won; Lee, Jung-Kil; Lee, Jung-Heon; Hur, Hyuk; Kim, Tae-Wan; Kim, Soo-Han

    2014-10-01

    Subsidence after anterior cervical reconstruction using a titanium mesh cage (TMC) has been a matter of debate. The authors investigated and analyzed subsidence and its effect on clinical and radiologic parameters after cervical reconstruction using a TMC for degenerative cervical disease. Thirty consecutive patients with degenerative cervical spine disorders underwent anterior cervical corpectomy followed by reconstruction with TMC. Twenty-four patients underwent a single-level corpectomy, and six patients underwent a two-level corpectomy. Clinical outcomes were assessed using a Visual Analogue Scale (VAS), the Japanese Orthopedic Association (JOA) score and the Neck Disability Index (NDI). Fusion status, anterior and posterior subsidence of the TMC, segmental angle (SA) and cervical sagittal angle (CSA) were assessed by lateral and flexion-extension radiographs of the neck. The mean follow-up period was 27.6 months (range, 24 to 49 months). The VAS, NDI and JOA scores were all significantly improved at the last follow-up. No instances of radiolucency or motion-related pseudoarthrosis were detected on radiographic analysis, yielding a fusion rate of 100%. Subsidence occurred in 28 of 30 patients (93.3%). The average anterior subsidence of the cage was 1.4 ± 0.9 mm, and the average posterior subsidence was 2.9 ± 1.2 mm. The SA and CSA at the final follow-up were significantly increased toward a lordotic angle. Anterior cervical reconstruction using TMC and plating in patients with cervical degenerative disease provides good clinical and radiologic outcomes. Cage subsidence occurred frequently, especially at the posterior part of the cage. Despite the prominent posterior subsidence of the TMC, SA and CSA were improved on final follow-up radiographs, suggesting that posterior subsidence may contribute to cervical lordosis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.

    Science.gov (United States)

    Han, Hyuk-Soo; Kang, Seung-Baik; Jo, Chris H; Kim, Sun-Hong; Lee, Jung-Ha

    2010-10-01

    Experimental and clinical studies on the accuracy of the intramedullary alignment method have produced different results, and few have addressed accuracy in the sagittal plane. Reported deviations are not only attributable to the alignment method but also to radiological errors. The purpose of this study was to evaluate the accuracy of the intramedullary alignment method in the sagittal plane using computed tomography (CT) and 3-dimensional imaging software. Thirty-one TKAs were performed using an intramedullary alignment method involving the insertion of a long 8-mm diameter rod into the medullary canal to the distal metaphysis of the tibia. All alignment instruments were set to achieve an ideal varus/valgus angle of 0° in the coronal plane and a tibial slope of 0° in the sagittal plane. The accuracy of the intramedullary alignment system was assessed by measuring the coronal tibial component angle and sagittal tibial slope angles, i.e., angles between the tibial anatomical axis and the tangent to the medial and lateral tibial plateau or the cut-surface. The mean coronal tibial component angle was 88.5° ± 1.2° and the mean tibial component slope in the sagittal plane was 1.6° ± 1.2° without anterior slope. Our intramedullary tibial alignment method, which involves passing an 8-mm diameter long rod through the tibial shaft isthmus, showed good accuracy (less than 3 degrees of variation and no anterior slope) in the sagittal plane in neutral or varus knees.

  7. Functional outcome of corpectomy in cervical spondylotic myelopathy

    Directory of Open Access Journals (Sweden)

    Williams Kanishka

    2009-01-01

    Full Text Available Background : Cervical spondylotic myelopathy (CSM is serious consequence of cervical intervertebral disk degeneration. Morbidity ranges from chronic neck pain, radicular pain, headache, myelopathy leading to weakness, and impaired fine motor coordination to quadriparesis and/or sphincter dysfunction. Surgical treatment remains the mainstay of treatment once myelopathy develops. Compared to more conventional surgical techniques for spinal cord decompression, such as anterior cervical discectomy and fusion, laminectomy, and laminoplasty, patients treated with corpectomy have better neurological recovery, less axial neck pain, and lower incidences of postoperative loss of sagittal plane alignment. The objective of this study was to analyze the outcome of corpectomy in cervical spondylotic myelopathy, to assess their improvement of symptoms, and to highlight complications of the procedure. Materials and Methods: Twenty-four patients underwent cervical corpectomy for cervical spondylotic myelopathy during June 1999 to July 2005.The anterior approach was used. Each patient was graded according to the Nuricks Grade (1972 and the modified Japanese Orthopaedic Association (mJOA Scale (1991, and the recovery rate was calculated. Results: Preoperative patients had a mean Nurick′s grade of 3.83, which was 1.67 postoperatively. Preoperative patients had a mean mJOA score of 9.67, whereas postoperatively it was 14.50. The mean recovery rate of patients postoperatively was 62.35% at a mean follow-up of 1 year (range, 8 months to 5 years.The complications included one case (4.17% of radiculopathy, two cases (8.33% of graft displacement, and two cases (8.33% of screw back out/failure. Conclusions: Cervical corpectomy is a reliable and rewarding procedure for CSM, with functional improvement in most patients.

  8. Sagittal alignment as a predictor of clinical adjacent segment pathology requiring surgery after anterior cervical arthrodesis.

    Science.gov (United States)

    Park, Moon Soo; Kelly, Michael P; Lee, Dong-Ho; Min, Woo-Kie; Rahman, Ra'Kerry K; Riew, K Daniel

    2014-07-01

    Postoperative malalignment of the cervical spine may alter cervical spine mechanics and put patients at risk for clinical adjacent segment pathology requiring surgery. To investigate whether a relationship exists between cervical spine sagittal alignment and clinical adjacent segment pathology requiring surgery (CASP-S) following anterior cervical fusion (ACF). Retrospective matched study. A total of 122 patients undergoing ACF between 1996 and 2008 were identified, with a minimum of 2 years of follow-up. Radiographs were reviewed to measure the sagittal alignment using C2 and C7 sagittal plumb lines, distance from the fusion mass plumb line to the C2 and C7 plumb lines, the alignment of the fusion mass, caudally adjacent disc angle, the sagittal slope angle of the superior end plate of the vertebra caudally adjacent to the fusion mass, T1 sagittal angle, overall cervical sagittal alignment, and curve patterns by Katsuura classification. A total of 122 patients undergoing ACF between 1996 and 2008 were identified, with a minimum of 1 year of follow-up. Patients were divided into groups according to the development of CASP (control/CASP-S) and by number/location of levels fused. Radiographs were reviewed to measure the sagittal alignment using C2 and C7 sagittal plumb lines, distance from the fusion mass plumb line to the C2 and C7 plumb lines, the alignment of the fusion mass, caudally adjacent disc angle, the sagittal slope angle of the superior end plate of the vertebra caudally adjacent to the fusion mass, T1 sagittal angle, overall cervical sagittal alignment, and curve patterns by Katsuura classification. Appropriate statistical tests were performed to calculate relationships between the variables and the development of CASP-S. No funds were received in support of this work. No benefits in any form have been or will be received from a commercial party related directly or indirectly to the subject of this article. The groups were similar with regard to

  9. A review of methods for evaluating the quantitative parameters of sagittal pelvic alignment.

    Science.gov (United States)

    Vrtovec, Tomaž; Janssen, Michiel M A; Likar, Boštjan; Castelein, René M; Viergever, Max A; Pernuš, Franjo

    2012-05-01

    The sagittal alignment of the pelvis represents the basic mechanism for maintaining postural equilibrium, and a number of methods were developed to assess normal and pathologic pelvic alignments from two-dimensional sagittal radiographs in terms of positional and anatomic parameters. To provide a complete overview of the existing methods for quantitative evaluation of sagittal pelvic alignment and summarize the relevant publications. Review article. An Internet search for terms related to sagittal pelvic alignment was performed to obtain relevant publications, which were further supplemented by selected publications found in their lists of references. By summarizing the obtained publications, the positional and anatomic parameters of sagittal pelvic alignment were described, and their values and relationships to other parameters and features were reported. Positional pelvic parameters relate to the position and orientation of the observed subject and are represented by the sacral slope, pelvic tilt, pelvic overhang, sacral inclination, sacrofemoral angle, sacrofemoral distance, pelvic femoral angle, pelvic angle, and sacropelvic translation. Anatomic pelvic parameters relate to the anatomy of the observed subject and are represented by the pelvisacral angle (PSA), pelvic incidence (PI), pelvic thickness (PTH), sacropelvic angle (PRS1), pelvic radius (PR), femorosacral posterior angle (FSPA), sacral table angle (STA), and sacral anatomic orientation (SAO). The review was mainly focused on the evaluation of anatomic pelvic parameters, as they can be compared among subjects and therefore among different studies. However, ambiguous results were yielded for normal and pathologic subjects, as the reported values show a relatively high variability in terms of standard deviation for every anatomic parameter, which amounts to around 10 mm for PTH and PR; 10° for PSA, PI, and SAO; 9° for PRS1 and FSPA; and 5° for STA in the case of normal subjects and is usually even

  10. Sagittal alignment and complications following lumbar 3-column osteotomy: does the level of resection matter?

    Science.gov (United States)

    Ferrero, Emmanuelle; Liabaud, Barthelemy; Henry, Jensen K; Ames, Christopher P; Kebaish, Khaled; Mundis, Gregory M; Hostin, Richard; Gupta, Munish C; Boachie-Adjei, Oheneba; Smith, Justin S; Hart, Robert A; Obeid, Ibrahim; Diebo, Bassel G; Schwab, Frank J; Lafage, Virginie

    2017-11-01

    OBJECTIVE Three-column osteotomy (3CO) is a demanding technique that is performed to correct sagittal spinal malalignment. However, the impact of the 3CO level on pelvic or truncal sagittal correction remains unclear. In this study, the authors assessed the impact of 3CO level and postoperative apex of lumbar lordosis on sagittal alignment correction, complications, and revisions. METHODS In this retrospective study of a multicenter spinal deformity database, radiographic data were analyzed at baseline and at 1- and 2-year follow-up to quantify spinopelvic alignment, apex of lordosis, and resection angle. The impact of 3CO level and apex level of lumbar lordosis on the sagittal correction was assessed. Logistic regression analyses were performed, controlling for cofounders, to investigate the effects of 3CO level and apex level on intraoperative and postoperative complications as well as on the need for subsequent revision surgery. RESULTS A total of 468 patients were included (mean age 60.8 years, mean body mass index 28.1 kg/m 2 ); 70% of patients were female. The average 3CO resection angle was 25.1° and did not significantly differ with regard to 3CO level. There were no significant correlations between the 3CO level and amount of sagittal vertical axis or pelvic tilt correction. The postoperative apex level significantly correlated with greater correction of pelvic tilt (2° per more caudal level, R = -0.2, p = 0.006). Lower-level 3CO significantly correlated with revisions for pseudarthrosis (OR = 3.88, p = 0.001) and postoperative motor deficits (OR = 2.02, p = 0.026). CONCLUSIONS In this study, a more caudal lumbar 3CO level did not lead to greater sagittal vertical axis correction. The postoperative apex of lumbar lordosis significantly impacted pelvic tilt. 3CO levels that were more caudal were associated with more postoperative motor deficits and revisions.

  11. [SPINO-PELVIC SAGITTAL ALIGNMENT IN PATIENTS WITH HIGH-GRADE L5 ISTHMIC SPONDYLOLISTHESIS].

    Science.gov (United States)

    Yang, Xi; Kong, Qingquan; Song, Yueming; Liu, Limin; Li, Tao; Gong, Quan; Zeng, Jiancheng; Liu, Hao

    2016-01-01

    To observe the character of spino-pelvic sagittal alignment in patients with high-grade L5 isthmic spondylolisthesis, and to analyze the sagittal alignment alteration after operation. Between January 2009 and June 2014, 25 patients with high-grade L5 isthmic spondylolisthesis underwent posterior surgery, and the clinical data were retrospectively analyzed as study group. There were 14 males and 11 females with a mean age of 42.5 years (range, 20-65 years). The mean disease duration was 6 months (range, 3-12 months). According to the Meyerding evaluating system, 15 cases were rated as degree III, and 10 cases as degree IV. Eighty healthy adult volunteers were recruited simultaneously as control group. The lumbar sacral angle (LSA), pelvic incidence (PI), pelvic tilt (PT), sacral slope (SS), lumbar lordosis (LL), thoracic kyphosis (TK), and sagittal vertical axis (SVA) were measured on preoperative and last follow-up standing full length lateral X-ray films. And these parameters were compared between study group (preoperative parameters) and control group. Then the patients in study group were divided into 2 subgroups according to Hresko's method: the balanced pelvis subgroup (n = 14) and unbalanced pelvis subgroup (n = 11). The sagittal parameters were compared between 2 subgroups, and the alteration of sagittal parameters before surgery and at last follow-up was analyzed in each subgroup respectively. All patients in study group were followed up 18 months on average (range, 6-48 months). After surgery, spondylolisthesis was reduced from degree III to degree 0 in 12 cases and to degree I in 3 cases, and from degree IV to degree 0 in 6 cases and to degree I in 4 cases. Bone fusion was obtained in all patients at last follow-up. The preoperative PI, SS, PT, and SVA of study group were significantly greater than those of control group (P spondylolisthesis have greater PI, abnormal lumbosacral kyphosis, and sagittal imbalance.

  12. The Influence of Natural Head Position on the Cervical Sagittal Alignment

    Directory of Open Access Journals (Sweden)

    Kuan Wang

    2017-01-01

    Full Text Available Introduction. This study investigated the relationship between the parameters related to the natural head position and cervical segmental angles and alignment of patients with neck pain. Material and Methods. The lateral radiographs of the cervical spine were collected from 103 patients and were used to retrospectively analyze the correlation between the natural head position, cervical local sagittal angles, and alignment. Sagittal measurements were as follows: cervical curvature classification, slope of McGregor’s line (McGS, local sagittal angles (C0–C2 angle, C2–C5 angle, C5–C7 angle, and C2–C7 angle, T1 slope, center of gravity of the head to sagittal vertical axis (CG–C7 SVA, and local sagittal alignment (C0–C2 SVA and C2–C7 SVA. Results. McGS was significantly correlated to C0–C2 angle (r=0.57, C0–C2 SVA (r=−0.53, C2–C7 SVA (r=−0.28, and CG–C7 SVA (r=−0.47. CG–C7 SVA was also significantly correlated to curvature type (r=0.27, C5–C7 angle (r=−0.37, and C2–C7 angle (r=−0.39. Conclusions. A backward shift with an extended head position may accompany a relatively normal curvature of the cervical spine. The effect of posture control in relieving abnormal mechanical state of the cervical spine needs to be further confirmed by biomechanical analysis.

  13. Differences in early sagittal plane alignment between thoracic and lumbar adolescent idiopathic scoliosis.

    Science.gov (United States)

    Schlösser, Tom P C; Shah, Suken A; Reichard, Samantha J; Rogers, Kenneth; Vincken, Koen L; Castelein, René M

    2014-02-01

    It has previously been shown that rotational stability of spinal segments is reduced by posteriorly directed shear loads that are the result of gravity and muscle tone. Posterior shear loads act on those segments of the spine that are posteriorly inclined, as determined by each individual's inherited sagittal spinal profile. Accordingly, it can be inferred that certain sagittal spinal profiles are more prone to develop a rotational deformity that may lead to idiopathic scoliosis; and lumbar scoliosis, on one end of the spectrum, develops from a different sagittal spinal profile than thoracic scoliosis on the other end. To examine the role of sagittal spinopelvic alignment in the etiopathogenesis of different types of idiopathic scoliosis. Multicenter retrospective analysis of lateral radiographs of patients with small thoracic and lumbar adolescent idiopathic scoliotic curves. We included 192 adolescent idiopathic scoliosis patients with either a thoracic (n=128) or lumbar (n=64) structural curve with a Cobb angle of less than 20° were studied. Children with other spinal pathology or with more severe idiopathic scoliosis were excluded, because this disturbs their original sagittal profile. Subjects who underwent scoliosis screening and had a normal spine were included in the control cohort (n=95). Thoracic kyphosis, lumbar lordosis, T9 sagittal offset, C7 and T4 sagittal plumb lines, pelvic incidence, pelvic tilt, and sacral slope, as well as parameters describing orientation in space of each individual vertebra between C7 and L5 and length of the posteriorly inclined segment. On standardized lateral radiographs of the spine, a systematic, semi-automatic measurement of the different sagittal spinopelvic parameters was performed for each subject using in-house developed computer software. Early thoracic scoliosis showed a significantly different sagittal plane from lumbar scoliosis. Furthermore, both scoliotic curve patterns were different from controls, but in a

  14. Novel Angular Measures of Cervical Deformity Account for Upper Cervical Compensation and Sagittal Alignment.

    Science.gov (United States)

    Protopsaltis, Themistocles S; Lafage, Renaud; Vira, Shaleen; Sciubba, Daniel; Soroceanu, Alex; Hamilton, Kojo; Smith, Justin; Passias, Peter G; Mundis, Gregory; Hart, Robert; Schwab, Frank; Klineberg, Eric; Shaffrey, Christopher; Lafage, Virginie; Ames, Christopher

    2017-08-01

    This is a retrospective review of a prospective multicenter database. This study introduces 2 new cervical alignment measures accounting for both cervical deformity (CD) and upper cervical compensation. Current descriptions of CD like the C2-C7 sagittal vertical axis (cSVA) do not account for compensatory mechanisms such as C0-C2 lordosis and pelvic tilt, which makes surgical planning difficult. The craniocervical angle (CCA) combines the slope of McGregor's line and the inclination from C7 to the hard palate. The C2-pelvic tilt (CPT) combines C2 tilt and pelvic tilt. Like the T1 pelvic angle, CPT is less affected by lower extremity and pelvic compensation. Novel and existing CD measures were correlated in 781 patients from a thoracolumbar deformity (TLD) database and 61 patients from a prospective CD database. CD patients were subanalyzed by region of deformity driver: cervical or cervico-thoracic junction. TLD patients were substratified according to whether or not they had CD as well, where CD was defined as cSVA>4 cm or T1 slope minus cervical lordosis mismatch (TS-CL) >20. TLD cohort: mean cSVA was 31.7±17.8 mm. Subanalysis of TLD patients with CD versus no-CD demonstrated significant differences in CCA (56.2 vs. 60.6, Paccount for both cervical sagittal alignment and upper cervical compensation and can be utilized in assessment of cervical alignment.

  15. Radiographic Restoration of Sagittal Spinopelvic Alignment After Posterior Lumbar Interbody Fusion in Degenerative Spondylolisthesis.

    Science.gov (United States)

    Kong, Ling-De; Zhang, Ying-Ze; Wang, Feng; Kong, Fan-Long; Ding, Wen-Yuan; Shen, Yong

    2016-03-01

    A retrospective study. This study was aimed to analyze the changes in spinopelvic parameters after surgical correction of degenerative spondylolisthesis and to determine which deformity is most responsible for changes in sagittal spinopelvic alignment. The basic deformities of degenerative spondylolisthesis are forward slippage of the vertebral body, segmental kyphotic angle, and loss of disk height. Correction of those deformities during surgery will subsequently affect the spinopelvic parameters. A few studies have reported the changes of sagittal spinopelvic alignment after surgical treatment of isthmic spondylolisthesis. However, there appears to be relatively little information regarding degenerative spondylolisthesis. Fifty-three patients with L4-L5 degenerative spondylolisthesis were included. All patients underwent posterior lumbar interbody fusion and posterior instrumentation. Back pain, as the clinical outcome, was evaluated by visual analogue scale (VAS). The preoperative and postoperative spinopelvic parameters, including sacral slope (SS), pelvic tilt (PT), lumbar lordosis (LL), and L1 axis S1 distance were measured, and then the correlations between spinopelvic parameters and local deformity parameters such as slip degree, slip angle (SA), and height of the intervertebral disk were evaluated. After surgical correction of local deformity, all spinopelvic parameters changed subsequently: PT and L1 axis S1 distance had a decrease, SS and LL had an increase. VAS score decreased from 6.1±2.3 before surgery to 2.4±1.7 at the final follow-up assessment. Patients with VAS score changes ≥3 showed significantly higher SS and LL, and lower PT compared with those with VAS score changes spondylolisthesis with posterior lumbar interbody fusion and posterior instrumentation resulted in relief of back pain, which may be associated with improvement of sagittal spinopelvic alignment. Surgeons should consider deformity parameters, especially the SA, in the surgical

  16. A Comparison of Plain Radiography with Computer Tomography in Determining Coronal and Sagittal Alignments following Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Solayar GN

    2017-07-01

    Full Text Available INTRODUCTION: Optimal coronal and sagittal component positioning is important in achieving a successful outcome following total knee arthroplasty (TKA. Modalities to determine post-operative alignment include plain radiography and computer tomography (CT imaging. This study aims to determine the accuracy and reliability of plain radiographs in measuring coronal and sagittal alignment following TKA. MATERIALS AND METHODS: A prospective, consecutive study of 58 patients undergoing TKA was performed comparing alignment data from plain radiographs and CT imaging. Hip- knee-angle (HKA, sagittal femoral angle (SFA and sagittal tibial angle (STA measurements were taken by two observers from plain radiographs and compared with CT alignment. Intra- and inter-observer correlation was calculated for each measurement. RESULTS: Intra-observer correlation was excellent for HKA (r>0.89 with a mean difference of 0.95 and STA (r>0.8 compared to SFA (r=0.5. When comparing modalities (radiographs vs CT, HKA estimations for both observers showed the least maximum and mean differences while SFA observations were the least accurate. CONCLUSION: Radiographic estimation of HKA showed excellent intra- and inter-observer correlation and corresponds well with CT imaging. However, radiographic estimation of sagittal plane alignment was less reliably measured and correlated less with CT imaging. Plain radiography was found to be inferior to CT for estimation of biplanar prosthetic alignment following TKA.

  17. Paraspinal muscle morphometry in cervical spondylotic myelopathy and its implications in clinicoradiological outcomes following central corpectomy: clinical article.

    Science.gov (United States)

    Thakar, Sumit; Mohan, Dilip; Furtado, Sunil V; Sai Kiran, Narayanam Anantha; Dadlani, Ravi; Aryan, Saritha; Rao, Arun S; Hegde, Alangar S

    2014-08-01

    The objective of this study was to assess the cross-sectional areas (CSAs) of the superficial, deep flexor (DF), and deep extensor (DE) paraspinal muscles in patients with cervical spondylotic myelopathy (CSM), and to evaluate their correlations with functional status and sagittal spinal alignment changes following central corpectomy with fusion and plating. In this retrospective study of 67 patients who underwent central corpectomy with fusion and plating for CSM, the CSAs of the paraspinal muscles were calculated on the preoperative T2-weighted axial MR images and computed as ratios with respect to the corresponding vertebral body areas (VBAs) and as flexor/extensor CSA ratios. These ratios were then compared with those in the normative population and analyzed with respect to various clinicoradiological factors, including pain status, Nurick grade, and segmental angle change at follow-up (SACF). The mean CSA values for all muscle groups and the DF/DE ratio were significantly lower in the study cohort compared with an age- and sex-matched normative study group (p < 0.001). Among various independent variables tested in a multivariate regression analysis, increasing age and female sex significantly predicted a lower total extensor CSA/VBA ratio (p < 0.001), while a longer duration of symptoms significantly predicted a greater total flexor/total extensor CSA ratio (p = 0.02). In patients undergoing single-level corpectomy, graft subsidence had a positive correlation with SACF in all patients (p < 0.05), irrespective of the preoperative segmental angle and curvature, while in patients undergoing 2-level corpectomy, graft subsidence demonstrated such a correlation only in the subgroup with lordotic curvatures (p = 0.02). Among the muscle area ratios, the DF/DE ratio demonstrated a negative correlation with SACF in the subgroup with preoperative straight or kyphotic segmental angles (p = 0.04 in the single corpectomy group, p = 0.01 in the 2-level corpectomy group

  18. Reliability of the Radiographic Sagittal and Frontal Tibiotalar Alignment after Ankle Arthrodesis.

    Directory of Open Access Journals (Sweden)

    Madeleine Willegger

    Full Text Available Accurate measurement of the tibiotalar alignment is important in radiographic outcome assessment of ankle arthrodesis (AA. In studies, various radiological methods have been used to measure the tibiotalar alignment leading to facultative misinterpretation of results. However, to our knowledge, no previous study has investigated the reliability of tibiotalar alignment measurement in AA. We aimed to investigate the reliability of four different methods of measurement of the frontal and sagittal tibiotalar alignment after AA, and to further clarify the most reliable method for determining the longitudinal axis of the tibia.Thirty-eight weight bearing anterior to posterior and lateral ankle radiographs of thirty-seven patients who had undergone AA with a two screw fixation technique were selected. Three observers measured the frontal tibiotalar angle (FTTA and the sagittal tibiotalar angle (STTA using four different methods. The methods differed by the definition of the longitudinal tibial axis. Method A was defined by a line drawn along the lateral tibial border in anterior to posterior radiographs and along the posterior tibial border in lateral radiographs. Method B was defined by a line connecting two points in the middle of the proximal and the distal tibial shaft. Method C was drawn "freestyle"along the longitudinal axis of the tibia, and method D was defined by a line connecting the center of the tibial articular surface and a point in the middle of the proximal tibial shaft. Intra- and interobserver correlation coefficients (ICC and repeated measurement ANOVA were calculated to assess measurement reliability and accuracy.All four methods showed excellent inter- and intraobserver reliability for the FTTA and the STTA. When the longitudinal tibial axis is defined by connecting two points in the middle of the proximal and the distal tibial shaft, the highest interobserver reliability for the FTTA (ICC: 0.980; CI 95%: 0.966-0.989 and for the

  19. Reliability of the Radiographic Sagittal and Frontal Tibiotalar Alignment after Ankle Arthrodesis.

    Science.gov (United States)

    Willegger, Madeleine; Holinka, Johannes; Nemecek, Elena; Bock, Peter; Wanivenhaus, Axel Hugo; Windhager, Reinhard; Schuh, Reinhard

    2016-01-01

    Accurate measurement of the tibiotalar alignment is important in radiographic outcome assessment of ankle arthrodesis (AA). In studies, various radiological methods have been used to measure the tibiotalar alignment leading to facultative misinterpretation of results. However, to our knowledge, no previous study has investigated the reliability of tibiotalar alignment measurement in AA. We aimed to investigate the reliability of four different methods of measurement of the frontal and sagittal tibiotalar alignment after AA, and to further clarify the most reliable method for determining the longitudinal axis of the tibia. Thirty-eight weight bearing anterior to posterior and lateral ankle radiographs of thirty-seven patients who had undergone AA with a two screw fixation technique were selected. Three observers measured the frontal tibiotalar angle (FTTA) and the sagittal tibiotalar angle (STTA) using four different methods. The methods differed by the definition of the longitudinal tibial axis. Method A was defined by a line drawn along the lateral tibial border in anterior to posterior radiographs and along the posterior tibial border in lateral radiographs. Method B was defined by a line connecting two points in the middle of the proximal and the distal tibial shaft. Method C was drawn "freestyle"along the longitudinal axis of the tibia, and method D was defined by a line connecting the center of the tibial articular surface and a point in the middle of the proximal tibial shaft. Intra- and interobserver correlation coefficients (ICC) and repeated measurement ANOVA were calculated to assess measurement reliability and accuracy. All four methods showed excellent inter- and intraobserver reliability for the FTTA and the STTA. When the longitudinal tibial axis is defined by connecting two points in the middle of the proximal and the distal tibial shaft, the highest interobserver reliability for the FTTA (ICC: 0.980; CI 95%: 0.966-0.989) and for the STTA (ICC: 0

  20. CORRELATION BETWEEN CERVICAL SAGITTAL ALIGNMENT AND FUNCTIONAL CAPACITY IN CERVICAL SPONDYLOSIS

    Directory of Open Access Journals (Sweden)

    Marcel Machado da Motta

    Full Text Available ABSTRACT Objective: To correlate the radiographic parameters of sagittal cervical alignment with quality of life and functional capacity in patients with cervical spondylosis under conservative treatment. Methods: This is an observational and prospective study in patients with cervical spondylosis under conservative treatment and without indication for surgery. The 52 patients included were divided into three groups: axial pain, radiculopathy, and cervical myelopathy. The radiographic parameters considered were cervical lordosis (CL, cervical sagittal vertical axis (CSVA, T1 slope (TS and the discrepancy between TS and CL (TS-CL. Quality of life and functional capacity were evaluated by the Neck Disability Index (NDI questionnaire. Pain was assessed by the Visual Analogue Scale (VAS. The correlation between the radiographic parameters and the clinical scores was evaluated by the Pearson correlations coefficient. Results: There was no difference in cervical radiographic parameters between the three groups. In the total of the sample, the mean value of the CSVA was 17.8o (±8.3o, CL, 22.4° (± 8.8°; TS, 29.3° (±6.6°, and TS-CL, 7.0° (±7.4°. Significant inverse correlation (r= -0.3, p=0.039 was observed between NDI and CL, but there was no significant correlation between CL and VAS. CSVA (p=0.541, TS (p=0.287 and TS-CL (p=0.287 had no significantly correlated with NDI or VAS. Conclusion: Considering patients with cervical spondylosis not candidates for surgery, the only sagittal parameter that correlated with functional capacity was LC. In these patients, the correlation between cervical alignment and quality of life needs to be better characterized.

  1. Correlation between lumbar intervertebral disc height and lumbar spine sagittal alignment among asymptomatic Asian young adults.

    Science.gov (United States)

    Zhang, Feng; Zhang, Kai; Tian, Hai-Jun; Wu, Ai-Min; Cheng, Xiao-Fei; Zhou, Tang-Jun; Zhao, Jie

    2018-02-12

    To investigate the distribution and characteristics of the lumbar intervertebral disc height (IDH) in asymptomatic Asian population and to determine whether the lumbar IDH is related to the lumbar spine sagittal alignment. A cohort of 169 cases of asymptomatic volunteers was enrolled from January 2014 to July 2016. All participants underwent magnetic resonance imaging of the lumbar spine and panoramic radiography of the spine. Panoramic radiographs of the spine were taken to evaluate pelvic incidence (PI), sacral slope (SS), and pelvic tilt (PT) using Surgimap® software. Roussouly classification was utilized to categorize all subjects according to the four subtypes of sagittal alignment. The IDH was measured on the MRI mid-saggital section of the vertebral body. The relationships between lumbar IDH and spine-pelvic parameters were also assessed using the Spearman correlation analysis. The reference value ranges of IDH in asymptomatic Asian volunteers between L1/2, L2/3, L3/4, L4/5, and L5/S1 were (6.25, 10.99), (6.97, 12.08), (7.42, 13.3), (7.76, 14.57),and (7.11, 13.12) mm, respectively. Based on the above reference value, the high lumbar intervertebral space is defined as more than 14 mm. According to the Roussouly Classification, there are 33 cases in type I, 48 in type II, 66 in type III, and 22 in type IV. According to the definition of the high IDH, there are two cases in type I, three in type II, nine in type III, and eight in type IV. The results indicated that people in the Roussouly III and IV subtypes had greater values for IDH compared to those of Roussouly I and II subtypes, and the spinopelvic parameters were partly correlated with IDH in different subtypes. In addition, levels L4-L5 showed the highest IDH for all four groups followed by the L3-L4 and L5-S1 levels, and the value of L3-L4 is equivalent to that of L5-S1. All type groups showed moderate and positive correlations between the PI and IDH except the level of L1-L2 in type IV. The IDH may

  2. Standing sagittal alignment of the whole axial skeleton with reference to the gravity line in humans.

    Science.gov (United States)

    Hasegawa, Kazuhiro; Okamoto, Masashi; Hatsushikano, Shun; Shimoda, Haruka; Ono, Masatoshi; Homma, Takao; Watanabe, Kei

    2017-05-01

    Human beings stand upright with the chain of balance beginning at the feet, progressing to the lower limbs (ankles, knees, hip joints, pelvis), each of the spinal segments, and then ending at the cranium to achieve horizontal gaze and balance using minimum muscle activity. The details of the alignment and balance of the chain, however, are not clearly understood, due to the lack of information regarding the three-dimensional (3D) orientation of all bony elements in relation to the gravity line (GL). We performed a clinical study to clarify the standing sagittal alignment of whole axial skeletons in reference to the GL using the EOS slot-scanning 3D X-ray imaging system with simultaneous force plate measurement in a healthy human population. The GL was defined as a vertical line drawn through the centre of vertical pressure measured by the force plate. The present study yielded a complete set of physiological alignment measurements of the standing axial skeleton from the database of 136 healthy subjects (a mean age of 39.7 years, 20-69 years; men: 40, women: 96). The mean offset of centre of the acoustic meati from the GL was 0.0 cm. The offset of the cervical and thoracic vertebrae was posterior to the GL with the apex of thoracic kyphosis at T7, 5.0 cm posterior to the GL. The sagittal alignment changed to lordosis at the level of L2. The apex of the lumbar lordosis was L4, 0.6 cm anterior to the GL, and the centre of the base of the sacrum (CBS) was just posterior to the GL. The hip axis (HA) was 1.4 cm anterior to the GL. The knee joint was 2.4 cm posterior and the ankle joint was 4.8 cm posterior to the GL. L4-, L5- and the CBS-offset in subjects in the age decades of 40s, 50s and 60s were significantly posterior to those of subjects in their 20s. The L5- and CBS-offset in subjects in their 50s and 60s were also significantly posterior to those in subjects in their 30s. HA was never posterior to the GL. In the global alignment, there was a positive correlation

  3. Sagittal Alignment as Predictor of Adjacent Segment Disease After Lumbar Transforaminal Interbody Fusion.

    Science.gov (United States)

    Sun, Jin; Wang, Jun-Jie; Zhang, Li-Wei; Huang, Hui; Fu, Na-Xin

    2018-02-01

    This study was carried out to explore the diagnostic value of sagittal measurements for adjacent segment disease after lumbar transforaminal interbody fusion (TLIF). A total of 163 subjects who underwent TLIF for lumbar disease were initially enrolled in the study from July 2013 to August 2017. Sagittal alignment including thoracic inlet and spinopelvic parameters was measured by using preoperative full-length freestanding radiographs. Multivariate logistic regression analysis was performed to evaluate these parameters as the diagnostic index for adjacent segment disease (ASD). A total of 153 patients completed the final follow-up, and the mean follow-up period was 40.6 months. There were 53 (35.3%) cases with ASD found after the TLIF in the enrolled subjects. Logistic regression analysis and receiver operating characteristic analysis confirmed that preoperative pelvic tilt (PT) of more than 24.1° and thoracic kyphosis (TK) of more than 23.3° were significant risk factors of ASD after TLIF (P < 0.05). We confirmed that PT of more than 24.3° and TK of more than 23.3° could be regarded as predictors of ASD after lumbar TLIF. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Rapid Hip Osteoarthritis Development in a Patient with Anterior Acetabular Cyst with Sagittal Alignment Change

    Directory of Open Access Journals (Sweden)

    Yasuhiro Homma

    2014-01-01

    Full Text Available Rapidly destructive coxarthrosis (RDC is rare and develops unusual clinical course. Recent studies suggest multiple possible mechanisms of the development of RDC. However the exact mechanism of RDC is still not clear. The difficulty of the study on RDC is attributed to its rareness and the fact that the data before the onset of RDC is normally unavailable. In this report, we presented the patient having the radiographic data before the onset who had rapid osteoarthritis (OA development after contralateral THA, which meets the current criteria of RDC. We thought that the increased posterior tilt of the pelvis after THA reinforced the stress concentration at pre-existed anterior acetabular cyst, thereby the destruction of the cyst was occurred. As a result the rapid OA was developed. We think that there is the case of rapid osteoarthritis developing due to alternating load concentration by posterior pelvic tilt on preexisting anterior acetabular cyst such as our patient among the cases diagnosed as RDC without any identifiable etiology. The recognition of sagittal alignment changes and anterior acetabular cyst may play important role in prediction and prevention of the rapid hip osteoarthritis development similar to RDC.

  5. Effects of mirror placement on sagittal alignment of the spine during acquisition of full-spine standing X-Rays.

    Science.gov (United States)

    Oe, Shin; Togawa, Daisuke; Yoshida, Go; Hasegawa, Tomohiko; Yamato, Yu; Yasuda, Tatsuya; Banno, Tomohiro; Arima, Hideyuki; Mihara, Yuki; Ushirozako, Hiroki; Matsuyama, Yukihiro

    2018-02-01

    The line of sight when whole-spine radiographs are taken has not been defined. In our 2012 health screening study (TOEI study), whole-spine radiographs were taken with the volunteers in the most relaxed position and with a horizontal gaze. However, in the TOEI 2014 study, a mirror was placed in front of their faces to unify their line of sight. To our knowledge, there are no reports on how the sagittal alignment changes when radiographs are taken using a mirror. The purpose of this study was to investigate how mirror placement impacted sagittal spinal alignment in whole-spine radiographs taken while standing. Volunteers who participated in both the TOEI 2012 and 2014 studies were recruited. Pelvic tilt (PT), lumbar lordosis (LL), thoracic kyphosis (TK), cervical lordosis (CL), slope of McGregor's line (McGS), and C7 sagittal vertical axis (C7 SVA) were examined using software. Three hundred fifty-four volunteers (142 males, 212 females, average age in 2012: 72 years) whose radiographs were evaluated in both previous studies were enrolled. The average parameters of 2012 and 2014 were: PT: 18° and 21° (P mirror placement could standardize the head's position. These results showed that the mirror placement retroflexed cervical alignment and caused the head to lean backward. It is important that a mirror is placed to unify the line of sight.

  6. Sagittal spino-pelvic alignment in adults: The Wakayama Spine Study.

    Directory of Open Access Journals (Sweden)

    Yoshiki Asai

    Full Text Available To establish the normal values of spino-pelvic alignment and to clarify the effect of age-related changes using large, community-based cohorts.In this study, data from 1461 participants (466 men, 995 women were analyzed. On lateral standing radiographs, the following parameters were measured: thoracic kyphosis (TK, lumbar lordosis (LL, pelvic tilt (PT, pelvic incidence (PI, and C7 sagittal vertical axis (SVA. All values are expressed as the mean±standard deviation. The Spearman rank correlation coefficient was used to examine correlations between variables of spino-pelvic parameters. Finally, we analyzed the relationship between age and spino-pelvic parameters. Therefore, we entered values for the body mass index (BMI, SVA, TK, and PI-LL into a multiple regression model to adjust for potential confounding factors.The SVA, TK, and PT increased with age, and LL decreased with age. Regarding sex differences, the TK was statistically significantly larger in men than in women, and LL, PT, and PI were statistically significantly smaller in men than in women. Correlation coefficients between the SVA and TK, between the SVA and PI-LL, and between TK and PI-LL were none, strong, and weak, respectively. Results of multiple regression analysis between age and spino-pelvic parameters showed that the standardized partial regression coefficients for the SVA, TK, and PI-LL were 0.17, 0.30, and 0.23, respectively, in men and 0.29, 0.32, and 0.23, respectively, in women.We found that all parameters were significantly associated with age in men and women. The SVA, TK, and PT increased with age, and LL decreased with age. Results of multiple regression analysis also demonstrated that the SVA, TK, and PI-LL are related to age. Indeed, the PI-LL value increased with age. In this study, a more excessive PI-LL mismatch was shown, indicating an increased risk of spinal malalignment. Differences in the absolute values of spino-pelvic parameters in each sex were small

  7. A Change in Lumbar Sagittal Alignment After Single-level Anterior Lumbar Interbody Fusion for Lumbar Degenerative Spondylolisthesis With Normal Sagittal Balance.

    Science.gov (United States)

    Kim, Chi Heon; Chung, Chun Kee; Park, Sung Bae; Yang, Seung Heon; Kim, Jung-Hee

    2017-08-01

    Retrospective analysis. The object is to assess the correlation between whole lumbar lordosis (LL) and the segmental angle (SA) after single-level anterior lumbar interbody fusion for degenerative lumbar spondylolisthesis. The restoration of the SA at lower lumbar spine is meaningful, considering it contributes approximately 60% of LL, and revision surgery due to flat back or adjacent segment pathology was necessary decades after the initial surgery. However, little is known about the change of whole lumbar curvature after single-level lower lumbar fusion surgery, especially for balanced spine. We included 41 consecutive patients (M:F=9:32; mean age, 59.8±9.3 y) with a single-level anterior lumbar interbody fusion surgery for low-grade degenerative spinal spondylolisthesis, with C7 plumb line of <5 cm and ≥2-year follow-up period. The operated levels were L4-L5 in 34 patients and L5-S1 in 7 patients. Whole LL, SA, pelvic tilt, and sacral slope were compared. According to the Macnab criteria, a favorable outcome (excellent, 21; good, 15) was achieved in 36/41 (88%; excellent, 21; good, 15) patients. LL and SA were significantly changed from -50.8±9.9 to -54.6±11.1 degrees and -15.6±6.1 to -18.7±5.1 degrees (P<0.01), and a positive correlation (r=0.43, P=0.01) was observed between LL and SA at postoperative month 24. The changes to the pelvic tilt and sacral slope were not significant. Whole lumbar sagittal alignment was influenced by single SA. Therefore, obtaining adequate segmental lordosis is desirable considering the effect on the whole spine for a long time.

  8. Computer navigation vs extramedullary guide for sagittal alignment of tibial components: radiographic study and meta-analysis.

    Science.gov (United States)

    Kuzyk, Paul R T; Higgins, Gordon A; Tunggal, James A W; Sellan, Michael E; Waddell, James P; Schemitsch, Emil H

    2012-04-01

    Sagittal alignment of tibial components using computer navigation was compared with conventional methods. A radiologic study was performed using 110 total knee arthroplasties from 3 groups: computer navigation, cutting block with extramedullary guide, and manual tilt of extramedullary guide. Posterior tibial slopes were measured from radiographs and compared using statistical methods. The cutting block method was the most accurate, and computer navigation was the most precise. The manual tilt group had the greatest variance, significantly greater than computer navigation. There was no significant difference between groups with respect to the percentage of knees with posterior slope within 3° of the desired slope. Meta-analysis of 10 studies found no reduction in outliers with computer navigation. Computer navigation offers greatest precision but does not reduce the number of outliers. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Tridimensional Analysis of Rotatory Subluxation and Sagittal Spinopelvic Alignment in the Setting of Adult Spinal Deformity.

    Science.gov (United States)

    Ferrero, Emmanuelle; Lafage, Renaud; Diebo, Bassel G; Challier, Vincent; Illharreborde, Brice; Schwab, Frank; Skalli, Wafa; Guigui, Pierre; Lafage, Virginie

    2017-07-01

    Retrospective single-center. To investigate rotatory subluxation (RS) in adult spinal deformity (ASD) with three-dimensional (3D) stereoradiographic images and analyze relationships between RS, transverse plane parameters, spinopelvic parameters, and clinical outcomes. Recent research has demonstrated that sagittal plane malalignment and listhesis correlate with ASD patient-reported outcomes. However, there is still a lack of knowledge regarding the clinical impact of 3D evaluation and rotatory subluxation. Recent developments in stereoradiography allow clinicians to obtain full-body standing radiographs with low-dose radiation and 3D reconstruction. One hundred thirty lumbar ASD patients underwent full-spine biplanar radiographs (EOS Imaging, Paris, France). Clinical outcomes were recorded. Using sterEOS software, spinopelvic parameters and lateral listhesis were measured. 3D transverse plane parameters included apical axial vertebral rotation, axial intervertebral rotation (AIR), and torsion index (sum of AIR in the curve). ASD patients were divided in three groups: AIR 10°. Groups were compared with respect to radiographic and clinical data. Correlations were performed between the transverse and sagittal plane parameters and clinical outcomes. Patients with AIR >10° were significantly older, with larger Cobb angle (39.5°) and greater sagittal plane deformity (pelvic incidence-lumbar lordosis mismatch 11.7° and pelvic tilt 22.6°). The AIR >10° group had significantly greater apical vertebra axial rotation apex (24.8°), torsion index (45°), and upper-level AIR (21.5°) than the two other groups. Overall, 27% of AIR patients did not have two-dimensional (2D) lateral listhesis. Patients with AIR >10° had significantly worse Oswestry Disability Index and more low back pain. For patients in which lateral listhesis was unreadable in 2D imaging, rotatory subluxation was revealed using stereoradiography and at an earlier disease stage. Moreover, different 3D

  10. Long term results of anterior corpectomy and fusion for cervical spondylotic myelopathy.

    Directory of Open Access Journals (Sweden)

    Rui Gao

    Full Text Available BACKGROUND: Results showed good clinical outcomes of anterior corpectomy and fusion (ACCF for patients with cervical spondylotic myelopathy (CSM during a short term follow-up; however, studies assessing long term results are relatively scarce. In this study we intended to assess the long term clinical and radiographic outcomes, find out the factors that may affect the long term clinical outcome and evaluate the incidence of adjacent segment disease (ASD. METHODS: This is a retrospective study of 145 consecutive CSM patients on ACCF treatment with a minimum follow-up of 5 years. Clinical data were collected from medical and operative records. Patients were evaluated by using the Japanese Orthopedic Association (JOA scoring system preoperatively and during the follow-up. X-rays results of cervical spine were obtained from all patients. Correlations between the long term clinical outcome and various factors were also analyzed. FINDINGS: Ninety-three males and fifty-two females completed the follow-up. The mean age at operation was 51.0 years, and the mean follow-up period was 102.1 months. Both postoperative sagittal segmental alignment (SSA and the sagittal alignment of the whole cervical spine (SACS increased significantly in terms of cervical lordosis. The mean increase of JOA was 3.8 ± 1.3 postoperatively, and the overall recovery rate was 62.5%. Logistic regression analysis showed that preoperative duration of symptoms >12 months, high-intensity signal in spinal cord and preoperative JOA score ≤ 9 were important predictors of the fair recovery rate (≤ 50%. Repeated surgery due to ASD was performed in 7 (4.8% cases. CONCLUSIONS: ACCF with anterior plate fixation is a reliable and effective method for treating CSM in terms of JOA score and the recovery rate. The correction of cervical alignment and the repeated surgery rate for ASD are also considered to be satisfactory.

  11. Quantitative evaluation of the lumbosacral sagittal alignment in degenerative lumbar spinal stenosis

    Science.gov (United States)

    Makirov, Serik K.; Jahaf, Mohammed T.; Nikulina, Anastasia A.

    2015-01-01

    Goal of the study This study intends to develop a method of quantitative sagittal balance parameters assessment, based on a geometrical model of lumbar spine and sacrum. Methods One hundred eight patients were divided into 2 groups. In the experimental group have been included 59 patients with lumbar spinal stenosis on L1-5 level. Forty-nine healthy volunteers without history of any lumbar spine pathlogy were included in the control group. All patients have been examined with supine MRI. Lumbar lordosis has been adopted as circular arc and described either anatomical (lumbar lordosis angle), or geometrical (chord length, circle segment height, the central angle, circle radius) parameters. Moreover, 2 sacral parameters have been assessed for all patients: sacral slope and sacral deviation angle. Both parameters characterize sacrum disposition in horizontal and vertical axis respectively. Results Significant correlation was observed between anatomical and geometrical lumbo-sacral parameters. Significant differences between stenosis group and control group were observed in the value of the “central angle” and “sacral deviation” parameters. We propose additional parameters: lumbar coefficient, as ratio of the lordosis angle to the segmental angle (Kl); sacral coefficient, as ratio of the sacral tilt (ST) to the sacral deviation (SD) angle (Ks); and assessment modulus of the mathematical difference between sacral and lumbar coefficients has been used for determining lumbosacral balance (LSB). Statistically significant differences between main and control group have been obtained for all described coefficients (p = 0.006, p = 0.0001, p = 0.0001, accordingly). Median of LSB value of was 0.18 and 0.34 for stenosis and control groups, accordingly. Conclusion Based on these results we believe that that spinal stenosis is associated with an acquired deformity that is measureable by the described parameters. It's possible that spinal stenosis occurs in patients with an

  12. Resolution of the more anteriorly positioned psoas muscle following correction of spinal sagittal alignment from spondylolisthesis: case report.

    Science.gov (United States)

    Syed, Hasan R; Yaeger, Kurt; Sandhu, Faheem A

    2017-04-01

    Several studies have described the radiographic, histological, and morphological changes to the paraspinal muscle in patients with chronic low-back pain due to degenerative diseases of the spine. Gross anatomical illustrations have shown that the psoas muscle lies lateral to the L4-5 vertebrae and subsequently thins and dissociates from the vertebral body at L5-S1 in a ventrolateral course. A "rising psoas" may influence the location of the lumbar plexus and result in transient neurological injury on lateral approach to the spine. It is postulated that axial back pain may be exacerbated by anatomical changes of paraspinal musculature as a direct result of degenerative spine conditions. To their knowledge, the authors present the first reported case of a more anteriorly positioned psoas muscle and its resolution following correction of spondylolisthesis in a 62-year-old woman. This case highlights the dynamic nature of degenerative spinal disorders and illustrates that psoas muscle position can be affected by sagittal balance. Normal anatomical positioning can be restored following correction of spinal alignment.

  13. Role of Ethnicity in Alignment Compensation: Propensity Matched Analysis of Differential Compensatory Mechanism Recruitment Patterns for Sagittal Malalignment in 288 ASD Patients From Japan, Korea, and United States.

    Science.gov (United States)

    Diebo, Bassel G; Gammal, Isaac; Ha, Yoon; Yoon, Seung Hwan; Chang, Jae Won; Kim, Byeongwoo; Matsumoto, Morio; Yamato, Yu; Takeuchi, Daisaku; Hosogane, Naobumi; Yagi, Mitsuru; Taneichi, Hiroshi; Schwab, Frank; Lafage, Virginie; Ames, Christopher

    2017-02-15

    Retrospective review of adult spinal deformity patients in a multiethnic database. To investigate the role of ethnicity on recruitment of compensatory mechanisms for sagittal spinal deformity. While the impacts of age, sex, and pelvic morphology on the ability to compensate for sagittal malalignment have been investigated, the role of ethnicity in compensatory mechanism recruitment is poorly understood. Patients from USA (85% Caucasian) >25 y/o were propensity matched by age, sex, and pelvic incidence with patients from Korea and Japan. Only primary patients or those with existing fusion below T12 were retained for analysis. Groups were subclassified by deformity severity (aligned: sagittal vertical axis (SVA) 100 mm). Radiographic measurements including pelvic retroversion, thoracic kyphosis, loss of lumbar lordosis (PI minus LL), cervical lordosis, and cervical SVA were compared between the groups. There were 288 patients (96 each in USA, KOR, JPN), with similar age (64-67 yr) and PI (49-53°). USA had smaller pelvic incidence minus lumbar lordosis in every alignment group (P <0.05). In moderate malalignment, JPN had more pelvic retroversion than USA (30° vs. 20°), and KOR had more thoracic hypokyphosis than USA (15 vs. 31°). In severe malalignment, JPN had more pelvic retroversion than USA (39° vs. 27°), and KOR had more thoracic hypokyphosis than USA (15° vs. 31°). KOR had smaller cSVA than USA in both aligned (11 vs. 27 mm) and moderate (19 vs. 31 mm) malalignment. In severe malalignment, KOR had less cervical lordosis (13° KOR vs. 15° USA vs. 27° JPN). All differences with P <0.05. Compensation for sagittal is ethnicity dependent. Korean patients favor thoracic compensation via hypokyphosis, and Japanese patients favor pelvic compensation via retroversion. Patient ethnicity should be considered when evaluating the sagittal plane and surgical correction strategies. 3.

  14. Cross-sectional study of neck pain and cervical sagittal alignment in air force pilots.

    Science.gov (United States)

    Moon, Bong Ju; Choi, Kyong Ho; Yun, Chul; Ha, Yoon

    2015-05-01

    There is a high prevalence of neck pain in air force pilots; however, the causes are not clear and are considered work-related. Kyphotic changes in the cervical spine have been known to cause neck pain. In this study, we investigated the association between neck pain and cervical kyphosis in air force pilots. This is a cross-sectional study of 63 Republic of South Korea Air Force pilots. We examined the C2-7 absolute rotation angle (ARA) using the posterior tangent method and other radiologic parameters on whole spine lateral radiographs. We divided the participants into a neck pain group (N = 32) and no neck pain group (N = 31), and subsequently analyzed the difference in radiographic parameters and clinical data between the two groups. There were no significant differences found in age, body mass index, total flight time, or aerobic or anaerobic exercise between the neck pain and control groups. The fighter pilots had higher 1-yr prevalence of neck pain than nonfighter pilots (84.4% vs. 15.6%). The lower C2-7 ARA (OR = 0.91, 95% CI 0.846, 0.979) and fighter type aircrafts (OR = 3.93, 95% CI 1.104, 13.989) were associated with neck pain. Fighter pilots experienced neck pain more frequently than the nonfighter pilots. Those fighter pilots suffering from neck pain were shown to have more kyphotic changes in the cervical spine than control pilots through evaluation of whole spine lateral radiographs using the posterior tangent method. These key findings suggest that the forces involved in flying a fighter type aircraft may affect cervical alignment and neck pain.

  15. Relationships among spinal mobility and sagittal alignment of spine and lower extremity to quality of life and risk of falls.

    Science.gov (United States)

    Ishikawa, Yoshinori; Miyakoshi, Naohisa; Hongo, Michio; Kasukawa, Yuji; Kudo, Daisuke; Shimada, Yoichi

    2017-03-01

    Spinal deformities can affect quality of life (QOL) and risk of falling, but no studies have explored the relationships of spinal mobility and sagittal alignment of spine and the lower extremities simultaneously. Purpose of this study is to clarify the relationship of those postural parameters to QOL and risk of falling. The study evaluated 110 subjects (41 men, 69 women; mean age, 73 years). Upright and flexion and extension angles for thoracic kyphosis, lumbar lordosis, and spinal inclination were evaluated with SpinalMouse ® . Total-body inclination and hip and knee flexion angles in upright position were measured from lateral photographs. Subjects were divided into Fallers (n=23, 21%) and Non-fallers (n=87, 79%) based on past history of falls. QOL was assessed using the Short Form 36 Health Survey (SF-36 ® ). Age, total-body inclination, spinal inclination upright and in extension, thoracic kyphosis in flexion, lumbar lordosis upright and in extension, and knee flexion correlated significantly with the SF-36. Multiple regression analysis revealed total-body inclination and knee flexion to have the most significant relationships with the SF-36. SF-36, total-body inclination, spinal inclination in extension, thoracic kyphosis in flexion, lumbar lordosis upright and in extension, and hip and knee flexion angles differed significantly between Fallers and Non-fallers (P<0.05 for all). Multivariate logistic regression analyses revealed lumbar lordosis in extension to be a significant predictor of falling (P=0.038). Forward-stooped posture and knee-flexion deformity could be important indicator of lower QOL. Moreover, limited extension in the lumbar spine could be a useful screening examination for fall prevention in the elderly. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Evaluation of Sagittal Spine-Pelvis-Lower Limb Alignment in Elderly Women with Pelvic Retroversion while Standing and Walking Using a Three-Dimensional Musculoskeletal Model

    Science.gov (United States)

    Hongo, Michio; Miyakoshi, Naohisa; Matsunaga, Toshiki; Yamada, Shin; Kijima, Hiroaki; Shimada, Yoichi

    2017-01-01

    Study Design In vivo biomechanical study using a three-dimensional (3D) musculoskeletal model for elderly individuals with or without pelvic retroversion. Purpose To evaluate the effect of pelvic retroversion on the sagittal alignment of the spine, pelvis, and lower limb in elderly females while standing and walking. Overview of Literature Patients with hip–spine syndrome have concurrent hip-joint and spine diseases. However, the dynamic sagittal alignment between the hip joint and spine has rarely been investigated. We used a 3D musculoskeletal model to evaluate global spinopelvic parameters, including spinal inclination and pelvic tilt (PT). Methods A total of 32 ambulant females (mean age=78 years) without assistance were enrolled in the study. On the basis of the radiographic measurement for PT, participants were divided into the pelvic retroversion group (R-group; PT≥20°) and the normal group (N-group; PT<20°). A 3D musculoskeletal motion analysis system was used to analyze the calculated value for the alignment of spine, pelvis, and lower limb, including calculated (C)-PT, sagittal vertical axis (C-SVA), pelvic incidence, lumbar lordosis, T1 pelvic angle (C-TPA), as well as knee and hip flexion angles while standing and walking. Results While standing, C-PT and C-TPA in the R-group were significantly larger than those in the N-group. Hip angle was significantly smaller in the R-group than in the N-group, unlike knee angle, which did not show difference. While walking, C-SVA and C-TPA were significantly increased, whereas C-PT decreased compared with those while standing. The maximum hip-flexion angle was significantly smaller in the R-group than in the N-group. There was a significant correlation between the radiographic and calculated parameters. Conclusions The 3D musculoskeletal model was useful in evaluating the sagittal alignment of the spine, pelvis, and leg. Spinopelvic sagittal alignment showed deterioration while walking. C-PT was significantly

  17. Bone-femoral component interface gap after sagittal mechanical axis alignment is filled with new bone after cementless total knee arthroplasty.

    Science.gov (United States)

    Kuriyama, Shinichi; Hyakuna, Katsufumi; Inoue, Satoshi; Kawai, Yasutsugu; Tamaki, Yasuyuki; Ito, Hiromu; Matsuda, Shuichi

    2018-05-01

    This study retrospectively evaluated the fate of mismatch between an uncemented femoral component and each femoral cut surface (i.e., wedge-shaped gap) relative to sagittal mechanical alignment in total knee arthroplasty (TKA). Primary TKA was performed on 99 consecutive knees. The femoral components were aligned to the sagittal mechanical axis with CT-based navigation. All patients were assessed with postoperative true lateral radiographs. Bone-side surfaces of the uncemented femoral component were divided into five zones: anterior flange, anterior chamfer, posterior chamfer, posterior part, and distal part, which were defined as zones 1 to 5, respectively. Bone filling of wedge-shaped gaps in each zone was evaluated after 1 year. Femoral anterior notching did not occur. However, wedge-shaped gaps were observed in at least one zone in 23 of 99 knees (23%), most frequently in zone 5 (18%). There were 9 and 7 gaps in zones 1 and 2, respectively. The femoral component showed malpositioning of approximately 3° of flexion in cases with wedge-shaped gaps in zones 2 and/or 5. After one year, 67% (6/9) of zone 1, 100% (7/7) of zone 2, and 94% (17/18) of zone 5 wedge-shaped gaps were filled in with new bone. Femoral alignment relative to sagittal mechanical axis caused wedge-shaped gaps due to unstable anterior bone cutting through hard bone, but the small gaps were not clinically significant and filled in within one year. Sagittal setting of the femoral component should aim for the anatomical axis rather than the mechanical axis. IV.

  18. How the neck affects the back: changes in regional cervical sagittal alignment correlate to HRQOL improvement in adult thoracolumbar deformity patients at 2-year follow-up.

    Science.gov (United States)

    Protopsaltis, Themistocles S; Scheer, Justin K; Terran, Jamie S; Smith, Justin S; Hamilton, D Kojo; Kim, Han Jo; Mundis, Greg M; Hart, Robert A; McCarthy, Ian M; Klineberg, Eric; Lafage, Virginie; Bess, Shay; Schwab, Frank; Shaffrey, Christopher I; Ames, Christopher P

    2015-08-01

    OBJECT Regional cervical sagittal alignment (C2-7 sagittal vertical axis [SVA]) has been shown to correlate with health-related quality of life (HRQOL). The study objective was to examine the relationship between cervical and thoracolumbar alignment parameters with HRQOL among patients with operative and nonoperative adult thoracolumbar deformity. METHODS This is a multicenter prospective data collection of consecutive patients with adult thoracolumbar spinal deformity. Clinical measures of disability included the Oswestry Disability Index (ODI), Scoliosis Research Society-22 Patient Questionnaire (SRS-22), and 36-Item Short-Form Health Survey (SF-36). Cervical radiographic parameters were correlated with global sagittal parameters within the nonoperative and operative cohorts. A partial correlation analysis was performed controlling for C-7 SVA. The operative group was subanalyzed by the magnitude of global deformity (C-7 SVA ≥ 5 cm vs Physical Component Summary (PCS), SRS Activity domain, and SRS Appearance domain. Baseline C2-7 SVA also correlated with SRS Pain and SRS Total. For the operative patients with baseline C-7 SVA ≥ 5 cm, the 2-year C2-7 SVA significantly correlated with 2-year Mental Component Summary, SRS Mental, SRS Satisfaction, and decreases in ODI. Decreases in C2-7 SVA at 2 years significantly correlated with lower ODI at 2 years. Using partial correlations while controlling for C-7 SVA, the C2-7 SVA correlated significantly with baseline ODI (r = 0.211, p = 0.002), PCS (r = -0.178, p = 0.009), and SRS Activity (r = -0.145, p = 0.034) for the entire cohort. In the subset of operative patients with larger thoracolumbar deformities, the change in C2-7 SVA correlated with change in ODI (r = -0.311, p = 0.03). CONCLUSIONS Changes in cervical lordosis correlate to HRQOL improvements in thoracolumbar deformity patients at 2-year follow-up. Regional cervical sagittal parameters such as CL and C2-7 SVA are correlated with clinical measures of

  19. Association of walking speed with sagittal spinal alignment, muscle thickness, and echo intensity of lumbar back muscles in middle-aged and elderly women.

    Science.gov (United States)

    Masaki, Mitsuhiro; Ikezoe, Tome; Fukumoto, Yoshihiro; Minami, Seigo; Aoyama, Junichi; Ibuki, Satoko; Kimura, Misaka; Ichihashi, Noriaki

    2016-06-01

    Age-related change of spinal alignment in the standing position is known to be associated with decreases in walking speed, and alteration in muscle quantity (i.e., muscle mass) and muscle quality (i.e., increases in the amount of intramuscular non-contractile tissue) of lumbar back muscles. Additionally, the lumbar lordosis angle in the standing position is associated with walking speed, independent of lower-extremity muscle strength, in elderly individuals. However, it is unclear whether spinal alignment in the standing position is associated with walking speed in the elderly, independent of trunk muscle quantity and quality. The present study investigated the association of usual and maximum walking speed with age, sagittal spinal alignment in the standing position, muscle quantity measured as thickness, and quality measured as echo intensity of lumbar muscles in 35 middle-aged and elderly women. Sagittal spinal alignment in the standing position (thoracic kyphosis, lumbar lordosis, and sacral anterior inclination angle) using a spinal mouse, and muscle thickness and echo intensity of the lumbar muscles (erector spinae, psoas major, and lumbar multifidus) using an ultrasound imaging device were also measured. Stepwise regression analysis showed that only age was a significant determinant of usual walking speed. The thickness of the lumbar erector spinae muscle was a significant, independent determinant of maximal walking speed. The results of this study suggest that a decrease in maximal walking speed is associated with the decrease in lumbar erector spinae muscles thickness rather than spinal alignment in the standing position in middle-aged and elderly women.

  20. Mapping of the anterior tibial profile to identify accurate reference points for sagittal alignment of tibial component in total knee arthroplasty.

    Science.gov (United States)

    Cinotti, G; Caruso, E; Orsina, L; La Torre, G; Ripani, F R

    2017-10-01

    Although standard instrumentation is the procedure most frequently used to implant a Total Knee Arthroplasty (TKA), high rates of malalignment of tibial component are reported using this technique. Anatomical landmarks for sagittal alignment have been little investigated and the best reference axis, which parallels the mechanical axis, is yet to be established. Mapping the Anterior Tibial Profile (ATP) may allow the identification of segmental zones of the ATP parallel to the mechanical axis which can be used to align the extramedullary rod. An intramedullary rod was positioned in line with the mechanical axis in 47 dried cadaveric tibiae. The rod was connected to a cutting jig and to an extramedullary rod. Digitalized images of lateral view radiographs were taken and the distance between the ATP and the extramedullary rod was measured at 10-mm intervals and at interpolated distances corresponding to every 2% of the tibial length. Segmental portions of the ATP exhibit an alignment parallel to the mechanical axis between points located at 58% and 90% and at 62% and 88% of the tibial length. Points placed at 50% of tibial length and 5mm proximal to the ankle joint generate the longer axis parallel to the mechanical axis. The orientation of sagittal tibial cut may be improved by aligning the extramedullary rod parallel to the ATP at definite points. Points placed at 50% of the tibial length and 5mm proximal to the ankle joint may be preferred since they generate the longer axis parallel to the mechanical axis and are more easily identified at surgery. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Cervical Sagittal Alignment Limited Adjustment After Selective Posterior Thoracolumbar/Lumbar Curve Correction in Patients With Lenke Type 5C Adolescent Idiopathic Scoliosis.

    Science.gov (United States)

    Wang, Fei; Zhou, Xiao-Yi; Xu, Xi-Ming; Yang, Yi-Lin; Zhu, Xiao-Dong; Bai, Yu-Shu; Li, Ming; Wei, Xian-Zhao

    2017-05-01

    A retrospective clinical and radiographic study. The aim of this study was to analyze the radiographic change in cervical sagittal alignment (CSA) and identify the possible factors influencing the postoperative CSA in selective posterior thoracolumbar/lumbar (TL/L) curve correction. The correlation between the CSA and thoracic sagittal alignment (TSA) is a well-recognized phenomenon in patients with thoracic idiopathic scoliosis. However, little has been published about the influence of TL/L curve instrumentation on CSA. Thirty patients with Lenke type 5C adolescent idiopathic scoliosis (AIS) received the selective posterior TL/L curves fusion by pedicle screws. Preoperative and postoperative radiographic and clinical parameters were analyzed. C2-C7 lordosis less than 0 was considered a lordotic cervical spine (LCS), whereas more than 0 was considered a kyphotic cervical spine (KCS). Preoperatively, 43% of patients showed a KCS, whereas the remaining 57% showed a LCS. C2-C7 lordosis was correlated with T1-slope, thoracic kyphosis (TK), and global-TK (Gl-TK) (P 5C AIS was related to the global TSA rather than TK and proximal TK. As time progresses, spontaneous adjustment of CSA is limited because of the inherent rigidity of the cervical spine. 4.

  2. Prospective multi-centric evaluation of upper cervical and infra-cervical sagittal compensatory alignment in patients with adult cervical deformity.

    Science.gov (United States)

    Ramchandran, Subaraman; Protopsaltis, Themistocles S; Sciubba, Daniel; Scheer, Justin K; Jalai, Cyrus M; Daniels, Alan; Passias, Peter G; Lafage, Virginie; Kim, Han Jo; Mundis, Gregory; Klineberg, Eric; Hart, Robert A; Smith, Justin S; Shaffrey, Christopher; Ames, Christopher P

    2018-02-01

    Reciprocal mechanisms for standing alignment have been described in thoraco-lumbar deformity but have not been studied in patients with primary cervical deformity (CD). The purpose of this study is to report upper- and infra-cervical sagittal compensatory mechanisms in patients with CD and evaluate their changes post-operatively. Global spinal alignment was studied in a prospective database of operative CD patients. Inclusion criteria were any of the following: cervical kyphosis (CK) > 10°, cervical scoliosis > 10°, cSVA (C2-C7 Sagittal vertical axis) > 4 cm or CBVA (Chin Brow Vertical Angle) > 25°. For this study, patients who had previous fusion outside C2 to T4 segments were excluded. Patients were sub-classified by increasing severity of cervical kyphosis [CL (cervical lordosis): low 0°-10°, CK-high > 10°] and cSVA (cSVA-low 0-4 cm, cSVA-mid 4-6 cm, cSVA-high > 6 cm) and were compared for pre- and 3-month post-operative regional and global sagittal alignment to determine compensatory recruitment. 75 CD patients (mean age 61.3 years, 56% women) were included. Patients with progressively larger CK had a progressive increase in C0-C2 (CL = 34°, CK-low = 37°, CK-high = 44°, p = 0.004), C2Slope and T1Slope-CL (p low = 33°, cSVA-mid = 40°, cSVA-high = 43°, p = 0.007) and pelvic tilt (cSVA-low = 14.9°, cSVA-mid = 24.1°, cSVA-high = 24.9°, p = 0.02). At 3 months post-op, with significant improvement in cervical alignment, there was relaxation of C0-C2 (39°-35°, p = 0.01) which positively correlated with magnitude of deformity correction. Patients with cervical malalignment compensate with upper cervical hyper-lordosis, presumably for the maintenance of horizontal gaze. As cSVA increases, patients also tend to exhibit increased pelvic retroversion. Following surgical treatment, there was relaxation of upper cervical compensation.

  3. Sagittal accuracy of tibial osteotomy position during in vivo tibial plateau levelling osteotomy performed without an alignment jig and cutting guide.

    Science.gov (United States)

    Craig, Andrew; Witte, Philip Georg; Scott, Harry William

    2017-01-16

    To assess the accuracy of tibial osteotomy location for tibial plateau levelling osteotomy (TPLO) in the sagittal plane and its effect on the postoperative tibial plateau angle (TPA), when performed without an alignment jig and saw guide. Also, to document the improvement gained with experience. Medical records and stifle radiographs of dogs undergoing TPLO, without the use of an alignment jig and saw guide, by one surgeon were reviewed (2010-2014). Postoperative radiographs were reviewed to record the distance and direction of eccentricity. Postoperative TPA was also recorded. In a series of 401 TPLO procedures, 231 met the inclusion criteria. The absolute distance of eccentricity (DOE) for all dogs was 3.0 ± 1.6 mm. When evaluating surgical experience, the DOE for the final 77 cases (2.72 ± 1.43 mm), the middle 77 cases (3.18 ± 1.49 mm), and the first 77 cases (3.24 ± 1.7 mm) were not significantly different (p = 0.07157). There was a very weak correlation between DOE and postoperative TPA (R = 0.029). The location of the tibial osteotomy when performing TPLO without an alignment jig and saw guide compared favourably with previously documented use of an alignment jig and saw guide. Whilst the location of the tibial osteotomy has a theoretical impact on the postoperative TPA, other factors appear to be of greater importance. Surgeon experience did not result in significant improvement in accuracy up to 231 procedures.

  4. Evolution of bone mineral density after percutaneous kyphoplasty in fresh osteoporotic vertebral body fractures and adjacent vertebrae along with sagittal spine alignment.

    Science.gov (United States)

    Korovessis, Panagiotis; Zacharatos, Spyridon; Repantis, Thomas; Michael, Andreas; Karachalios, Dionysios

    2008-06-01

    Prospective controlled cohort study of 27 adult osteoporotic patients who underwent kyphoplasty for fresh osteoporotic spinal fractures. To define the evolution of vertebral bone mineral density (BMD) at kyphoplasty and adjacent levels along with sagittal spinal alignment to contribute to the etiology of adjacent vertebral fractures after augmentation. Osteoporotic compression fractures can be effectively treated with methylmethacrylate vertebral augmentation. However, to the authors' knowledge the effect of vertebral augmentation on the vertebral endplate BMD of the augmented and adjacent nonaugmented levels has not as yet been described. Twenty-seven consecutive selected patients (9 men, 18 women), with an average age of 72+/-9 years underwent 1, 2, or 3-level percutaneous kyphoplasty for painful fresh osteoporotic vertebral fractures at the thoracolumbar spine. All patients were radiologically examined with plain roentgenograms, computed tomography, and magnetic resonance imaging. Lateral dual energy x-ray absorptiometry in the augmented and on the adjacent vertebrae (1 level above and below kyphoplasty) was used to measure BMD preoperatively to the last postoperative observation in the subchondral bone of the vertebral endplates. Anthropometric data, sagittal global balance (plumbline), and segmental spine reconstruction (vertebral body height, Gardner kyphotic angle) were recorded and analyzed. The patients were followed for at least 2 years. Kyphoplasty was performed between T12 and L5. A total of 48 vertebral bodies were augmented. Thirteen patients received 1 level and the remaining 14 received 2 or 3-level kyphoplasty. No significant changes in the sagittal spinal balance were shown postoperatively. Gardner kyphotic angle and posterior vertebral body height improved postoperatively, however, insignificantly. Significant [analysis of variance (ANOVA), P=0.008] increase of anterior vertebral body height in the fractured vertebra was achieved postoperatively

  5. PEEK Cages versus PMMA Spacers in Anterior Cervical Discectomy: Comparison of Fusion, Subsidence, Sagittal Alignment, and Clinical Outcome with a Minimum 1-Year Follow-Up

    Science.gov (United States)

    Krüger, Marie T.; Sircar, Ronen; Kogias, Evangelos; Scholz, Christoph; Volz, Florian; Scheiwe, Christian; Hubbe, Ulrich

    2014-01-01

    Purpose. To compare radiographic and clinical outcomes after anterior cervical discectomy in patients with cervical degenerative disc disease using PEEK cages or PMMA spacers with a minimum 1-year follow-up. Methods. Anterior cervical discectomy was performed in 107 patients in one or two levels using empty PEEK cages (51 levels), Sulcem PMMA spacers (49 levels) or Palacos PMMA spacers (41 levels) between January, 2005 and February, 2009. Bony fusion, subsidence, and sagittal alignment were retrospectively assessed in CT scans and radiographs at follow-up. Clinical outcome was measured using the VAS, NDI, and SF-36. Results. Bony fusion was assessed in 65% (PEEK cage), 57% (Sulcem), and 46% (Palacos) after a mean follow-up of 2.5 years. Mean subsidence was 2.3–2.6 mm without significant differences between the groups. The most pronounced loss of lordosis was found in PEEK cages (−4.1°). VAS was 3.1 (PEEK cage), 3.6 (Sulcem), and 2.7 (Palacos) without significant differences. Functional outcome in the PEEK cage and Palacos group was superior to the Sulcem group. Conclusions. The substitute groups showed differing fusion rates. Clinical outcome, however, appears to be generally not correlated with fusion status or subsidence. We could not specify a superior disc substitute for anterior cervical discectomy. This trial is registered with DRKS00003591. PMID:25110734

  6. Effects of Lordotic Angle of a Cage on Sagittal Alignment and Clinical Outcome in One Level Posterior Lumbar Interbody Fusion with Pedicle Screw Fixation

    Directory of Open Access Journals (Sweden)

    Ji-Ho Lee

    2015-01-01

    Full Text Available This study aims to assess the differences in the radiological and clinical results depending on the lordotic angles of the cage in posterior lumbar interbody fusion (PLIF. We reviewed 185 segments which underwent PLIF using two different lordotic angles of 4° and 8° of a polyetheretherketone (PEEK cage. The segmental lordosis and total lumbar lordosis of the 4° and 8° cage groups were compared preoperatively, as well as on the first postoperative day, 6th and 12th months postoperatively. Clinical assessment was performed using the ODI and the VAS of low back pain. The pre- and immediate postoperative segmental lordosis angles were 12.9° and 12.6° in the 4° group and 12° and 12.0° in the 8° group. Both groups exhibited no significant different segmental lordosis angle and total lumbar lordosis over period and time. However, the total lumbar lordosis significantly increased from six months postoperatively compared with the immediate postoperative day in the 8° group. The ODI and the VAS in both groups had no differences. Cages with different lordotic angles of 4° and 8° showed insignificant results clinically and radiologically in short-level PLIF surgery. Clinical improvements and sagittal alignment recovery were significantly observed in both groups.

  7. Restoration of lumbopelvic sagittal alignment and its maintenance following transforaminal lumbar interbody fusion (TLIF): comparison between straight type versus curvilinear type cage.

    Science.gov (United States)

    Kim, Jong-Tae; Shin, Myung-Hoon; Lee, Ho-Jin; Choi, Du-Yong

    2015-11-01

    To evaluate a radiological and clinical difference between the curvilinear type cages compared to the straight type cages for the restoration of lumbopelvic sagittal alignment and its maintenance after transforaminal lumbar interbody fusion (TLIF) procedure. 68 patients who underwent single-level TLIF using either the straight type or curvilinear type cage were retrospectively reviewed. Assessment of the lumbopelvic parameters and the height of disc space was performed before surgery as well as 2 days, 6 and 12 months after surgery. Clinical outcome was assessed using VAS and ODI. The curvilinear type cages were positioned more anteriorly than the straight type. Restoration of the segmental lordosis (SL) in the curvilinear group was significantly greater than the straight group and at 12 months of follow-up, the straight group showed greater decrease in the disc height than the curvilinear group. The straight group failed to show improvement of lumbar lordosis (LL), while the curvilinear group showed significant restoration of LL and could maintain it to the 6 months of follow-up. In both groups, pelvic tilt was significantly decreased and it lasted to 6 months in the straight group; whereas in the curvilinear group, it was maintained to the last follow-up of 12 months. There were no significant differences between the two groups in mean VAS and ODI score over the follow-up period. This study demonstrates that the curvilinear type cage is superior to the straight type cage in improving the SL and maintaining both the restored lumbopelvic parameters and elevated disc height. These results could be attributable to the anterior position of the curvilinear cage which permits easy restoration of segmental lordosis and less sinking of cages.

  8. [Computer-aided discectomy and corpectomy in anterior reconstruction of the injured thoracolumbar spine. A prospective, controlled clinical trial].

    Science.gov (United States)

    Blattert, T R; Springwald, J; Glasmacher, S; Siekmann, H; Josten, C

    2008-11-01

    In anterior reconstruction of the unstable thoracolumbar spine, discectomy and corpectomy are technically demanding steps requiring maximal surgical precision. This study investigated the feasibility of computer-aided guidance for discectomy and corpectomy. It also analysed the precision, advantages, and disadvantages of the procedure. Vertebral body fractures of the non-osteoporotic thoracolumbar spine addressed by discectomy/corpectomy and subsequent implant interposition (cage, tricortical strut graft) for anterior reconstruction were included. All surgical steps were done under endoscopic assistance. In the trial group, discectomy and corpectomy were performed with computer-aided guidance; in the control group, no computer navigation was used. The time required for surgery was noted. To assess surgical precision, decentralization of the implant in the frontal plane was measured in postoperative x-rays and computed tomography. Additionally, parallel alignment of vertebral body end plates with the implant was evaluated. The trial group (TG) consisted of 16 patients, and the control group (CG) of 10 patients. Fractures were localized between T10 and L1 in TG, and between T9 and L1 in CG. Operating time was significantly shorter in CG: 104+/-28 min compared with 229+/-64 min in TG (pComputer-aided guidance for anterior reconstruction of the thoracolumbar spine is a technically feasible option that may help in performing discectomy and corpectomy. However, this technique significantly prolongs the operating time. There were no differences in the precision of implant positioning between the groups. However, during discectomy the use of computer navigation may possibly add to the protection of adjacent end plates.

  9. Range of motion after thoracolumbar corpectomy

    DEFF Research Database (Denmark)

    Gehrchen, Martin; Hegde, Sajan K; Moldavsky, Mark

    2017-01-01

    STUDY DESIGN: An in vitro biomechanical study. OBJECTIVES: To compare the biomechanical stability of traditional and low-profile thorocolumbar anterior instrumentation after a corpectomy with cross-connectors. Dual-rod anterior thoracolumbar lateral plates (ATLP) have been used clinically...... to stabilize the thorocolumbar spine. METHODS: The stability of a low-profile dual-rod system (LP DRS) and a traditional dual-rod system (DRS) was compared using a calf spine model. Two groups of seven specimens were tested intact and then in the following order: (1) ATLP with two cross-connectors and spacer......; (2) ATLP with one cross-connector and spacer; (3) ATLP with spacer. Data were normalized to intact (100 %) and statistical analysis was used to determine between-group significances. RESULTS: Both constructs reduced motion compared to intact in flexion-extension and lateral bending. Axial rotation...

  10. Oblique Corpectomy to Manage Cervical Myeloradiculopathy

    Directory of Open Access Journals (Sweden)

    Chibbaro Salvatore

    2011-01-01

    Full Text Available Background. The authors describe a lateral approach to the cervical spine for the management of spondylotic myeloradiculopathy. The rationale for this approach and surgical technique are discussed, as well as the advantages, disadvantages, complications, and pitfalls based on the author's experience over the last two decades. Methods. Spondylotic myelo-radiculopathy may be treated via a lateral approach to the cervical spine when there is predominant anterior compression associated with either spine straightening or kyphosis, but without vertebral instability. Results. By using a lateral approach, the lateral aspect of the cervical spine and the vertebral artery are easily reached and visualized. Furthermore, the lateral part of the affected intervertebral disc(s, uncovertebral joint(s, vertebral body(ies, and posterior longitudinal ligament can be removed as needed to decompress nerve root(s and/or the spinal cord. Conclusion. Multilevel cervical oblique corpectomy and/or lateral foraminotomy allow wide decompression of nervous structures, while maintaining optimal stability and physiological motion of the cervical spine.

  11. Analysis of sagittal spinopelvic parameters in achondroplasia.

    Science.gov (United States)

    Hong, Jae-Young; Suh, Seung-Woo; Modi, Hitesh N; Park, Jong-Woong; Park, Jung-Ho

    2011-08-15

    Prospective radiological analysis of patients with achondroplasia. To analyze sagittal spinal alignment and pelvic orientation in achondroplasia patients. Knowledge of sagittal spinopelvic parameters is important for the treatment of achondroplasia, because they differ from those of the normal population and can induce pain. The study and control groups were composed of 32 achondroplasia patients and 24 healthy volunteers, respectively. All underwent lateral radiography of the whole spine including hip joints. The radiographic parameters examined were sacral slope (SS), pelvic tilt, pelvic incidence (PI), S1 overhang, thoracic kyphosis, T10-L2 kyphosis, lumbar lordosis (LL1, LL2), and sagittal balance. Statistical analysis was performed to identify significant differences between the two groups. In addition, correlations between parameters and symptoms were sought. Sagittal spinopelvic parameters, namely, pelvic tilt, pelvic incidence, S1 overhang, thoracic kyphosis, T10-L2 kyphosis, lumbar lordosis 1 and sagittal balance were found to be significantly different in the patient and control groups (P achondroplasia patients and normal healthy controls. The present study shows that sagittal spinal and pelvic parameters can assist the treatment of spinal disorders in achondroplasia patients.

  12. Corpectomy cage subsidence with rectangular versus round endcaps.

    Science.gov (United States)

    Deukmedjian, Armen R; Manwaring, Jotham; Le, Tien V; Turner, Alexander W L; Uribe, Juan S

    2014-09-01

    Corpectomy cages with rectangular endcaps utilize the stronger peripheral part of the endplate, potentially decreasing subsidence risk. The authors evaluated cage subsidence during cyclic biomechanical testing, comparing rectangular versus round endcaps. Fourteen cadaveric spinal segments (T12-L2) were dissected and potted at T12 and L2, then assigned to a rectangular (n=7) or round (n=7) endcap group. An L1 corpectomy was performed and under uniform conditions a cage/plate construct was cyclically tested in a servo-hydraulic frame with increasing load magnitude. Testing was terminated if the test machine actuator displacement exceeded 6mm, or the specimen completed cyclic loading at 2400 N. Number of cycles, compressive force and force-cycles product at test completion were all greater in the rectangular endcap group compared with the round endcap group (cycles: 3027 versus 2092 cycles; force: 1943 N versus 1533 N; force-cycles product: 6162kN·cycles versus 3973 kN·cycles), however these differences were not statistically significant (p ⩾ 0.076). After normalizing for individual specimen bone mineral density, the same measures increased to a greater extent with the rectangular endcaps (cycles: 3014 versus 1855 cycles; force: 1944 N versus 1444 N; force-cycles product: 6040 kN·cycles versus 2980 kN·cycles), and all differences were significant (p⩽0.030). The rectangular endcap expandable corpectomy cage displayed increased resistance to subsidence over the round endcap cage under cyclic loading as demonstrated by the larger number of cycles, maximum load and force-cycles product at test completion. This suggests rectangular endcaps will be less susceptible to subsidence than the round endcap design. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Sagittal plane considerations and the pelvis in the adult patient.

    Science.gov (United States)

    Schwab, Frank; Lafage, Virginie; Patel, Ashish; Farcy, Jean-Pierre

    2009-08-01

    Research update, focused review. Identify the role of the pelvis in the setting of adults with spinal deformity. Sagittal plane alignment is increasingly recognized as a critical parameter in the setting of adult spinal deformity. Additionally, pelvic parameters reveal to be a key component in the regulation of sagittal alignment. Analysis of the pelvis in the sagittal plane is commonly assessed by 3 angular measurements: the pelvic incidence (morphologic parameter directly linked to sagittal morphotypes), the pelvic tilt (or pelvis retroversion used to maintain an upright posture in the setting of spinal deformity), and the sacral slope. Recent work using force plate technology has revealed that in the setting of anterior trunk inclination ("spinal imbalance"), the pelvis shifted posteriorly (toward the heels) in order to maintain a balanced mass distribution. The complex relationship between pelvic and spinal parameter were investigated in order to construct predictive formulas of postoperative spinopelvic alignment. It has emerged that pelvic tilt is highly correlated with patient self reported function (ODI, SF-12, and SRS). It has become evident that good clinical outcome in the treatment of spinal deformity requires proper alignment. Pelvis parameters play an essential role not only in terms of spine morphotypes but also in regulating standing balance and postoperative alignment. Thus, optimal treatment of a patient with spinal deformity requires integration of the pelvis in the preoperative evaluation and treatment plan.

  14. Minimally invasive central corpectomy for ossified posterior longitudinal ligament in the cervical spine.

    Science.gov (United States)

    Hirano, Yoshitaka; Mizuno, Junichi; Nakagawa, Hiroshi; Itoh, Yasunobu; Kubota, Keiichi; Watanabe, Sadayoshi; Matsuoka, Hidenori; Numazawa, Shinichi; Tomii, Masato; Watanabe, Kazuo

    2011-01-01

    Minimally invasive central corpectomy (MICC) for cervical segmental ossified posterior longitudinal ligament (OPLL) is described. The procedure of MICC includes upper- or lower-half central corpectomy of the involved cervical spine, transdiscal decompression of the adjacent disc level, dissection and partial removal of the OPLL, removal of the OPLL behind the vertebral body via these windows, and fusion with cylindrical titanium cages. Anterior plate fixation is not necessary. From January 2008 to December 2009 we surgically treated three patients with cervical OPLL by MICC. All three patients showed remarkable improvement of their symptoms within a few days after the operation. No neurological or radiological complication was observed during that period. MICC is beneficial in avoiding complete corpectomy and long fusion, usage of an anterior plate, and usage of a large external orthosis. MICC also reduces the risk of postoperative esophageal perforation due to a screw backing out of the plate. 2010 Elsevier Ltd. All rights reserved.

  15. Preventing Construct Subsidence Following Cervical Corpectomy: The Bump-stop Technique.

    Science.gov (United States)

    Shaw, Kenneth Aaron; Griffith, Matthew; Mottern, Edward T; Gloystein, David M; Devine, John G

    2018-02-01

    Cervical corpectomy is a viable technique for the treatment of multilevel cervical spine pathology. Despite multiple advances in both surgical technique and implant technology, the rate of construct subsidence can range from 6% for single-level procedures to 71% for multilevel procedures. In this technical note, we describe a novel technique, the bump-stop technique, for cervical corpectomy. The technique positions the superior and inferior screw holes such that the vertebral bodies bisect them. This allows for fixation in the dense cortical bone of the endplate while providing a buttress to corpectomy cage subsidence. We then discuss a retrospective case review of 24 consecutive patients, who were treated using this approach, demonstrating a lower than previously reported cage subsidence rate.

  16. Minimally Invasive Thoracic Corpectomy: Surgical Strategies for Malignancy, Trauma, and Complex Spinal Pathologies

    Directory of Open Access Journals (Sweden)

    Rohan R. Lall

    2012-01-01

    Full Text Available The rapid expansion of minimally invasive techniques for corpectomy in the thoracic spine provides promise to redefine treatment options in this region. Techniques have evolved permitting anterior, lateral, posterolateral, and midline posterior corpectomy in a minimally invasive fashion. We review the numerous techniques that have been described, including thoracoscopy, tubular retraction, and various instrumentation techniques. Minimally invasive techniques are compared to their open predecessors from a technical and complication standpoint. Advantages and disadvantages of different approaches are also considered, with an emphasis on surgical strategies and nuance.

  17. Transient paralysis shortly after anterior cervical corpectomy and fusion.

    Science.gov (United States)

    Zhang, Ji-dong; Xia, Qun; Ji, Ning; Liu, Yan-cheng; Han, Yue; Ning, Shang-long

    2013-02-01

    To report three cases of transient paralysis shortly after (within 4 hours) anterior cervical corpectomy and fusion (ACCF), and investigate the possible causes. Clinical and radiological data of three cases (two men and one woman, aged 41-61 years) were analyzed retrospectively. All three patients underwent ACCF for cervical spondylotic myelopathy. The decompressed segments were located in C(5) , C(6) and C(5) + C(6-7) discs, respectively. Paralysis occurred from 30 minutes to 4 hours after surgery. In two cases the paralysis was complete; it was incomplete in the third. All patients received immediate dehydration, neurotrophic drugs and high-dose methylprednisolone therapy upon recognition of their paralysis. Meanwhile, cervical MRIs were performed and showed no significant hematomas compressing the cervical spinal cord; spinal cord edema was clearly evident in all cases. In two cases the paralysis resolved within 2 hours of diagnosis and immediate medication. In the third case, because the neurological symptoms were incompletely resolved 24 hours after beginning medication, a second laminoplasty was performed. During decompression, tremendous pressure was released from the cervical spinal cord. The neurological symptoms had resolved completely by 1 week after decompression. The precise cause for transient paralysis after these anterior cervical surgeries is not yet clear. Spinal cord ischemia-reperfusion injury is generally regarded as the most likely cause. Therefore, a combination of cervical spinal cord edema and limited anterior decompression space may have been the main contributing factors to the paralysis reported here. Early diagnosis and early intervention to relieve the paralysis can restore spinal cord function and result in a satisfactory prognosis. © 2013 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  18. Graft Subsidence and Revision Rates Following Anterior Cervical Corpectomy: A Clinical Study Comparing Different Interbody Cages.

    Science.gov (United States)

    Weber, Michael H; Fortin, Maryse; Shen, Jian; Tay, Bobby; Hu, Serena S; Berven, Sigurd; Burch, Shane; Chou, Dean; Ames, Christopher; Deviren, Vedat

    2017-11-01

    Retrospective cohort study. To assess the subsidence and revision rates associated with different interbody cages following anterior cervical corpectomy and reconstruction. Different interbody cages are currently used for surgical reconstruction of the anterior and middle columns of the spine following anterior cervical corpectomy. However, subsidence and delayed union/nonunion associated with allograft and cage reconstruction are common complications, which may require revision with instrumentation. We reviewed the cases of 75 patients who underwent cervical corpectomy and compared the radiographic graft subsidence and revision rates for fibula allograft, titanium mesh cage, titanium expandable cage, and carbon fiber cages. Subsidence was calculated by comparing the immediate postoperative lateral x-ray films to those obtained during follow-up visits. The average graft subsidence was 3 mm and revision rate was 25% for fibula allograft versus 2.9 mm and 11.1%, 2.9 mm and 18.8% for titanium mesh cages and titanium expandable cages, respectively. The average graft subsidence for carbon fiber cages was 0.7 mm with no revision surgery in this subset. Our findings suggest that subsidence and revision rates following anterior corpectomy and interbody fusion could be minimized with the use of a carbon fiber cage.

  19. Prognostic Value of Lordosis Decrease in Radiographic Adjacent Segment Pathology After Anterior Cervical Corpectomy and Fusion.

    Science.gov (United States)

    Liu, Yin; Li, Na; Wei, Wei; Deng, Jing; Hu, Yuequn; Ye, Bin; Wang, Wei

    2017-10-31

    While cervical lordosis alteration is not uncommon after anterior cervical arthrodesis, its influence on radiological adjacent segment pathology (RASP) is still unclear. Biomechanical changes induced by arthrodesis may contribute to ASP onset. To investigate the correlation between cervical lordosis decrease and RASP onset after anterior cervical corpectomy and fusion (ACCF) and to determine its biomechanical effect on adjacent segments after surgery, 80 CSM patients treated with ACCF were retrospectively studied, and a baseline finite element model of the cervical spine as well as post-operation models with normal and decreased lordosis were established and validated. We found that post-operative lordosis decrease was prognostic in predicting RASP onset, with the hazard ratio of 0.45. In the FE models, ROM at the adjacent segment increased after surgery, and the increase was greater in the model with decreased lordosis. Thus, post-operative cervical lordosis change significantly correlated with RASP occurrence, and it may be of prognostic value. The biomechanical changes induced by lordosis change at the adjacent segments after corpectomy may be one of the mechanisms for this phenomenon. Restoring a well lordotic cervical spine after corpectomy may reduce RASP occurrence and be beneficial to long-term surgical outcomes.

  20. Pedicle subtraction osteotomy in elderly patients with degenerative sagittal imbalance.

    Science.gov (United States)

    Cho, Kyu-Jung; Kim, Ki-Tack; Kim, Whoan-Jeang; Lee, Sang-Hoon; Jung, Jae-Hoon; Kim, Young-Tae; Park, Hae-Bong

    2013-11-15

    Retrospective, radiographical analysis. To evaluate pedicle subtraction osteotomy (PSO) as a means of correcting severe degenerative sagittal imbalance in elderly patients. PSO in patients with degenerative sagittal imbalance is likely to cause more complications than in patients with iatrogenic flatback deformity. This study analyzed 34 patients who underwent fusion to the sacrum, with a minimum 2-year follow-up. Age of the patients were in the range from 58 to 73 with the mean at 65.5 years. PSO was performed at one segment in all cases, consisting of L3 (n = 26), L4 (n = 4), L2 (n = 3), and L1 (n = 1). The average number of levels fused was 8.15. Ten patients had structural interbody fusion at the lumbosacral junction. Applying PSO at one segment, the mean correction of the lordotic angle at the osteotomy site was 33.3°, of which the loss of correction (LOC) was 4.0° at the last visit. The correction of lumbar lordosis was 33.7° and the LOC was 8.5°. The sagittal C7 plumb was 215.9 mm before surgery, corrected to 35.1 mm after surgery, and changed to 95.9 mm by the last visit. The correction of the sagittal C7 plumb was 119.9 mm and the LOC was 60.9 mm. There was substantial LOC in lumbar lordosis and sagittal C7 plumb. In 10 patients with addition of posterior lumbar interbody fusion, the LOC of lumbar lordosis was 7.4°, which was less than 9° in those without it. PSO for the correction of degenerative sagittal imbalance in elderly patients resulted in correction of sagittal alignment with a significant LOC of lumbar lordosis and sagittal C7 plumb. The LOC of lumbar lordosis occurred at both the osteotomy and non-osteotomy site. The addition of anterior column support is helpful to maintain correction and reduce complications. N/A.

  1. The sagittal pelvic tilt index as a criterion in the evaluation of spondylolisthesis. Preliminary observations.

    Science.gov (United States)

    Schwab, F J; Farcy, J P; Roye, D P

    1997-07-15

    Radiographic analysis of a pediatric population with spondylolisthesis was performed to examine sagittal plane pelvic rotation and degree of slip over time. To determine whether the degree of standing sagittal offset of L5 with respect to the acetabulum correlated with slip progression and symptoms. The natural history of isthmic spondylolisthesis remains unclear. Attempts to predict slip progression in the clinical setting, and thus the possible need for eventual surgical intervention, remain imprecise. Predicting slip progression based on sagittal alignment of the L5 vertebra with respect to the acetabulum has been proposed by some investigators. Fifty-two children and adolescents were followed clinically and radiographically for an average of 5.6 years. Serial lateral standing radiographs that included the hips and lumbar spine were measured to compute a sagittal pelvic tilt index. The latter value is a ratio of relative distances from the center of S2 to the projection of L5 and the center of the femoral heads on the horizontal. Of the 52 patients studied, 38 have remained asymptomatic without significant slip progression or change in sagittal pelvic tilt index ratio. Of the original group, 13 patients had significant symptoms and revealed a decrease in the sagittal pelvic tilt index over time. Eight of the 13 stabilized at the end of adolescence, whereas 5 had continued decrease in the sagittal pelvic tilt index ratio. These five required operative treatment for pain and progressive slip. The sagittal pelvic tilt index gives the examiner an objective measure of the stability of the lumbosacral junction by quantifying the relationship between S2, the center of the hip, and L5. A decreasing sagittal pelvic tilt index ratio in this preliminary series correlated with slip progression and risk of conservative treatment failure, whereas those patients with a stable sagittal pelvic tilt index did not progress and remained clinically asymptomatic.

  2. Developing a System for Efficient Analysis of Lumbosacral Sagittal Balance

    Directory of Open Access Journals (Sweden)

    D. M. Zhuk

    2015-01-01

    Full Text Available Lumbosacral sagittal balance is the neutral vertical alignment in the sagittal plane to provide decreasing stress loading on muscular-ligamentous structures. The achieving sagittal balance is a basis to provide successful surgical treatment and minimize further complications. As of today, there is no standard quantitative evaluation method of sagittal lumbo-sacral balance, which allows conducting its effective analysis and planning surgical treatment taking into consideration the preservation of normal biomechanics of lumbosacral spine. The goal of the study is to develop a diagnostic system for individual correction of lumbo-sacral sagittal balance by the author’s method with automatic counting and optimized matching of data values based on a specified number of terms using medical visualization data. This study has been conducted with RMAPE’s Department of Traumatology and Orthopedic Surgery. To solve the problem, a random searching algorithm has been exploited. The stop condition of the algorithm was to achieve the objective function value in adjusted interval, initial points of which are the calculated (angular values. The interaction of the angular values, used in the proposed method has been investigated, and their proportional change has been proved. Moreover, the mathematical dependence among geometrical and anatomical parameters of lumbosacral spine has been determined. Based on conducted study, a number of algorithms enabling the automation of the individual determination of optimal lumbosacral balance’s parameters at preoperative planning stage for patients with vertebral column diseases have been created. This allows us to raise physician’s efficiency, minimize mid- and long-term risk of postoperative complications, and avoid reoperations, and prognosticate long-term complications already performed surgery.

  3. Radiological outcomes of static vs expandable titanium cages after corpectomy: a retrospective cohort analysis of subsidence.

    Science.gov (United States)

    Lau, Darryl; Song, Yeohan; Guan, Zhe; La Marca, Frank; Park, Paul

    2013-04-01

    Mesh cages have commonly been used for reconstruction after corpectomy. Recently, expandable cages have become a popular alternative. Regardless of cage type, subsidence is a concern following cage placement. To assess whether subsidence rates differ between static and expandable cages, and identify independent risk factors for subsidence and extent of subsidence when present. A consecutive population of patients who underwent corpectomy between 2006 and 2009 was identified. Subsidence was assessed via x-ray at 1-month and 1-year follow-ups. In addition to cage type, demographic, medical, and cage-related covariates were recorded. Multivariate models were used to assess independent associations with rate, odds, and extent of subsidence. Of 91 patients, 44.0% had expandable cages and 56.0% had static cages. One-month subsidence rate was 36.3%, and the 1-year subsidence rate was 51.6%. Expandable cages were independently associated with higher rates and odds of subsidence in comparison with static cages. Infection, trauma, and footplate-to-vertebral body endplate ratio of less than 0.5 were independent risk factors for subsidence. The presence of prongs on cages and posterior fusion 2 or more levels above and below corpectomy level had lower rates and odds of subsidence. Infection and cage placement in the thoracic or lumbar region had greater extent of subsidence when subsidence was present. Expandable cages had higher rates and risk of subsidence in comparison with static cages. When subsidence was present, expandable cages had greater magnitudes of subsidence. Other factors including footplate-to-vertebral body endplate ratio, prongs, extent of supplemental posterior fusion, spinal region, and diagnosis also impacted subsidence.

  4. Clinical experience using polyetheretherketone (PEEK) intervertebral structural cage for anterior cervical corpectomy and fusion.

    Science.gov (United States)

    Kasliwal, Manish K; O'Toole, John E

    2014-02-01

    Anterior cervical corpectomy and fusion (ACCF) is commonly performed for various pathologies involving the cervical spine. Although polyetheretherketone (PEEK) cages have been widely used following anterior cervical discectomy and fusion (ACDF), clinical literature demonstrating its efficacy following ACCF is sparse. A retrospective review of patients enrolled in a prospective database who underwent single/multi-level ACCF was performed. Fifty-nine patients were identified who underwent corpectomy reconstruction with PEEK cages for symptomatic degenerative, neoplastic, infectious, or traumatic pathologies of the cervical spine. Thirty-five patients having at least 6 months follow-up (FU) were included in the final analysis. The mean age of patients was 51 years (range, 18-81 years) with FU ranging from 6 to 33 months (mean, 6.6 months). None of the patients had dysphagia at last FU. There was no implant failure with fusion occurring in all patients. While 57% of patients (20/35) remained stable with no progression of myelopathy, 43% (15/35) improved one (11 patients) or two (four patients) Nurick grades after surgery. The use of PEEK cages packed with autograft or allograft is safe and effective following anterior cervical corpectomy, demonstrating high fusion rates and good clinical results. This synthetic material obviates the morbidity associated with autograft harvest and possible infectious risks of allograft. The wide array of cage dimensions facilitates ease of use in patients of all sizes and appears safe for use in the typical pathologic conditions encountered in the cervical spine. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Partial lateral corpectomy associated with pediculectomy to treat extradural chondroma in a dog: technique description

    Directory of Open Access Journals (Sweden)

    P.V.T. Marinho

    2014-10-01

    Full Text Available This study aimed to describe in detail the surgical technique of partial lateral corpectomy (PLC associated with pediculectomy to treat an in vitro extradural chondroma. A 12-year old female Cocker Spaniel was seen in the hospital with proprioceptive ataxia of hind limbs associated with extradural compression between the 1st and 2nd lumbar vertebrae. The owner opted for euthanasia since the patient's condition changed due to simultaneous illnesses that culminated in a poor prognosis. The patient's body was formally ceded to perform experimental spinal decompression. The technique was effective to completely remove the epidural mass with minimal manipulation of the spinal cord.

  6. Cervical corpectomy with preserved posterior vertebral wall for cervical spondylotic myelopathy: a randomized control clinical study.

    Science.gov (United States)

    Ying, Zhang; Xinwei, Wang; Jing, Zhang; Shengming, Xu; Bitao, Lv; Tao, Zhang; Wen, Yuan

    2007-06-15

    Cervical corpectomy with preserved posterior vertebral wall (CPW) had been performed by the senior author (Y.W.) since 1999. A prospective study had been conducted to evaluate the efficacy of CPW since 2001. To validate the clinical outcome of CPW against conventional corpectomy (CC). Anterior surgical managements of cervical spondylotic myelopathy (CSM) include discectomy and corpectomy. Both have significant disadvantages, including low fusion rates and residual symptoms. A procedure incorporating multilevel discectomy, corpectomy with preserved posterior vertebral wall, autograft and plating was described. By keeping the posterior vertebral wall (PW), infringement of the vein plexus and spinal canal was avoided and more fusion site was available. From March 2001 to March 2004, 178 cases of CSM were randomized to undergo CPW (n = 89) or CC (n = 89). Arthrodesis was done with autogenous iliac bone graft or titanium cage supplemented with anterior self-lock plates in both groups. Operation time, blood loss, days of hospitalization, the numbers and types of complications, and preoperative and postoperative JOA scores were recorded. Fusion rate, segmental lordosis, and disc height were assessed by roentgenography. Three-dimensional reconstructions of CT scan were used to confirm fusion evidence. Average operation time and blood loss decreased significantly in the CPW group (98.06 +/- 19.42 minutes, and 131.69 +/- 62.41 mL) as compared with those in the CC group (108.45 +/- 22.35 minutes, and 181.57 +/- 82.10 mL) (P < 0.05). There were 2 cases of epidural bleeding and 1 case of CSF leak in the CC group. Other complications were minor. JOA improvement scores were similar in both groups. Roentgenograms showed that the fusion rate was 100% at 6 months postoperatively in both groups. CT scans showed that PW fused with grafts and bone dust in cages. Improvement in segmental lordosis and disc height was similar in both groups. CPW is a feasible procedure for anterior

  7. Vertebral autograft used as bone transplant for anterior cervical corpectomy: technical note.

    Science.gov (United States)

    Rieger, Andreas; Holz, Carsten; Marx, Thomas; Sanchin, Lhagva; Menzel, Matthias

    2003-02-01

    In this prospective patient study, we used a surgical technique for autograft bone fusion during anterior cervical corpectomy (ACC) in patients experiencing cervical spondylotic myelopathy. We packed the resected bone material of the corpectomy into a titanium mesh cage. To evaluate the efficacy of our autograft technique, we analyzed the results according to neurological outcome, radiological outcome, and complications. Between 1995 and 1998, 27 ACC operations were performed for cervical spondylotic myelopathy caused by multisegmental cervical spondylosis. In all patients, decompression of the cervical canal and/or spinal nerve roots was performed by a median cervical corpectomy by an anterior approach. After the ACC was completed, a titanium mesh cage, which was variable in diameter and length, was filled with morselized and impacted bone material from the cervical corpectomy and was then implanted. An anterior cervical plate was placed in all patients to achieve primary stability of the cervical vertebral column. Age, sex, pre- and postoperative myelopathy, number of decompressed levels, radiological results, and complications were assessed. The severity of myelopathy was graded according to the scoring system of the Japanese Orthopaedic Association. Symptomatic improvement of neurological deficits was achieved in 80% of the patients. The mean preoperative Japanese Orthopaedic Association score improved from 13.1 to 15.2 postoperatively (P < 0.05). No patient demonstrated worsening of myelopathic symptoms. Radiological follow-up studies demonstrated complete bony fusion in all patients. A vertical movement of 2.25 +/- 0.43 mm of the titanium cage into the adjacent vertebral bodies was observed in 24 patients. In patients with either a lordotic or neutral cervical spinal axis postoperatively, the axis remained unchanged during the entire follow-up period. The results of this study demonstrate that transplantation of autograft bone material harvested during the

  8. Postoperative change in sagittal balance after Kyphoplasty for the treatment of osteoporotic vertebral compression fracture.

    Science.gov (United States)

    Yokoyama, Kunio; Kawanishi, Masahiro; Yamada, Makoto; Tanaka, Hidekazu; Ito, Yutaka; Kawabata, Shinji; Kuroiwa, Toshihiko

    2015-04-01

    The influence of vertebral cement augmentation on spinal sagittal balance is unknown. The present study aimed to analyze the changes in total spinal alignment after Kyphoplasty in VCF patients. The study involved 21 VCF patients who underwent Kyphoplasty. In all patients, lateral radiographs of the entire spine were taken preoperatively and 1 month after surgery, to measure the pelvic incidence (PI), sacral slope (SS), pelvic tilt (PT), lumbar lordosis (LL), sagittal vertical axis (SVA), and spinosacral angle (SSA). These parameters were compared between VCF patients and 30 healthy volunteers. In VCF patients, the parameters were compared before and after Kyphoplasty. In VCF patients, preoperative SVA was 7.00 ± 3.9 cm, showing a significant shift to anterior sagittal balance as compared to the healthy group (1.45 ± 2.7 cm) (P vertebra (r = 0.792, P < 0.01). VAS score decreased from 7.98 ± 1.8 before Kyphoplasty to 2.38 ± 2.3 postoperatively (P < 0.0001). Total spinal alignment is shifted to anterior sagittal balance in VCF patients. Kyphoplasty plays a role not only in reducing pain associated with fractures but also in improving sagittal imbalance in the treatment of painful vertebral compression fracture.

  9. Anatomy-related risk factors for the subsidence of titanium mesh cage in cervical reconstruction after one-level corpectomy.

    Science.gov (United States)

    Wu, Jianxin; Luo, Dan; Ye, Xiaojian; Luo, Xuyao; Yan, Lisheng; Qian, Haiping

    2015-01-01

    To clarify anatomy-related risk factors in the cervical spine with subsidence of titanium mesh cage (TMC) after one-level cervical corpectomy and fusion, we have assessed the radiological examinations and clinical outcomes for 236 patients. All the patients were underwent one-level corpectomy and TMC fusion between August 2003 and March 2006. The effects of the cervical posture, segmental curvature and endplate gradient on the postoperative phenomenon for these patients were evaluated. Our results suggested that in the patients who were followed up for 12 months, TMC subsidence occurred in 54 (28.6%) cases. C6 corpectomy had a significant higher risk (26/60, 43.3%) for TMC subsidence, which was correlated with the variation of the gradient of the vertebral endplates against cervical levels. Although the clinical outcome was comparable with those in the literature, the patients may have subsidence-related problems such as neck-shoulder pain, neurological deterioration and instrumental failure. In conclusion, to reduce the incidence of subsidence, TMC design should be optimized to be in line with anatomic characteristics of the cervical spine.

  10. Pedicle subtraction osteotomies (PSO) in the lumbar spine for sagittal deformities.

    Science.gov (United States)

    Berjano, Pedro; Aebi, Max

    2015-01-01

    The narrow correlation between sagittal alignment parameters and clinical outcomes has been widely established, demonstrating that improper sagittal alignment is a clinical condition that is associated with increased pain and limitations in patients' functional ability. Lumbar pedicle subtraction osteotomy (PSO) is indicated in the treatment of large sagittal (more than 25° of rigid loss of lordosis) deformities of the lumbar spine or its combination with coronal deformity, especially when they are rigid. Indication should be based on careful assessment of the severity of symptoms, functional impairment, functional expectations of the patient, general clinical condition and surgical and anesthesiological team experience. Risk should be carefully assessed and discussed to obtain appropriate informed consent. Surgical planning includes selection of the safest levels for the upper and lower instrumented vertebra, site of the osteotomy, modality of fixation, and, most importantly angular value of the correction goal (target lumbar lordosis). Failure to adequately obtain the necessary amount of sagittal correction is the most frequent cause of failure and reoperation. PSO is a valuable surgical procedure in correction of severe hypolordosis (=relative kyphosis) in the lumbar spine. It is a demanding procedure for the surgeon, the anesthesiologist and the intensive care team. Although its complication rate is high, it has a substantial positive impact in the quality of life of patients, including the elderly.

  11. Evaluation of palatal rugae pattern in different sagittal skeletal relationship adolescent subjects

    OpenAIRE

    Oral, Ekrem; Buyuk, S. Kutalmi?; Simsek, Huseyin

    2017-01-01

    Abstract The purpose of this study was to evaluate the morphological structure of palatal rugae in Turkish orthodontic subjects with different sagittal skeletal malocclusions. Orthodontic dental casts of 105 patients (Class I [23 females, 12 males]; 35, Class II [18 females, 17 males]; and 35, Class III [14 females, 21 males] 10?22 years old) were analyzed for rugae patterns. Palatal rugae pattern and number, direction of rugae alignment, shape of incisive papilla were analyzed. Modified Thom...

  12. Intraoperative Simulated Weightbearing Lateral Foot Imaging: The Clinical Utility and Ability to Predict Sagittal Plane Position of the First Ray in Lapidus Fusion.

    Science.gov (United States)

    Boffeli, Troy J; Mahoney, Kevin J

    The sagittal plane relationship of the first to second ray is a primary determinant of proper alignment in Lapidus midfoot fusion as assessed both clinically and on postoperative weightbearing lateral radiographs. The traditional approach to intraoperative fluoroscopic imaging allows for accurate assessment of fixation placement and intermetatarsal angle correction but only a crude evaluation of final sagittal plane alignment. Surgeons have used various methods in an attempt to load the foot during lateral imaging. This had led to inconsistent results and the potential for poor outcome. Skepticism exists regarding the ability of simulated weightbearing fluoroscopy to predict the final outcome, and evidence is lacking to support this practice. A prospective investigation was performed to assess the correlation of the first to second ray sagittal plane alignment as demonstrated on intraoperative simulated weightbearing lateral foot imaging studies and the 10-week postoperative lateral weightbearing radiograph. A consistent simulated weightbearing technique was used prospectively with 50 consecutive cases of Lapidus midfoot fusion with the goal of achieving parallel sagittal plane alignment of the first and second metatarsals with no divergence. Although 47 cases had no divergence and 3 had divergence with mild first ray elevatus, all 50 cases demonstrated a direct correlation between the intraoperative simulated and postoperative full weightbearing images. In conclusion, we believe the findings from our intraoperative imaging technique are a reliable predictor of first ray sagittal plane alignment in Lapidus midfoot fusion. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Is there a sagittal imbalance of the spine in isthmic spondylolisthesis? A correlation study

    Science.gov (United States)

    Ilharreborde, Brice; Dauzac, Cyril; Lenoir, Thibault; Rillardon, Ludovic; Guigui, Pierre

    2007-01-01

    Recent studies suggested a predominant role of spinopelvic parameters to explain lumbosacral spondylolisthesis pathogeny. We compare the pelvic incidence and other parameters of sagittal spinopelvic balance in adolescents and young adults with developmental spondylolisthesis to those parameters in a control group of healthy volunteers. We compared the angular parameters of the sagittal balance of the spine in a cohort of 244 patients with a developmental L5–S1 spondylolisthesis with those of a control cohort of 300 healthy volunteers. A descriptive and correlation study was performed. The L5 anterior slipping and lumbosacral kyphosis in spondylolisthesis patients was described using multiple regression analysis study. Our study demonstrates that the related measures of sagittal spinopelvic alignment are disturbed in adolescents and young adults with developmental spondylolisthesis. These subjects stand with an increased sacral slope, pelvic tilt and lumbar lordosis but with a decreased thoracic kyphosis. Pelvic incidence was significantly higher in spondylolisthesis patients as compared with controls but was not clearly correlated with the grade of slipping. We showed the same “sagittal balance strategy” in spondylolisthesis patients as in the control group regarding correlations between pelvic incidence, sacral slope, pelvic tilt and lumbar lordosis. We believe that the lumbosacral kyphosis is a stronger factor than pelvic incidence which need to be taken into account as a predominant factor in theories of pathogenesis of lumbosacral spondylolithesis. We thus believe that increased lumbar lordosis associated with L5–S1 spondylolisthesis is secondary to the high pelvic incidence and is an important factor causing high shear stresses at the L5–S1 pars interarticularis. However, the “local” sagittal imbalance of the lumbosacral junction is compensated by adjacent mobile segments in the upper lumbar spine, the pelvis orientation and the thoracic spine

  14. Morphological segmentation for sagittal plane image analysis.

    Science.gov (United States)

    Bezerra, F N; Paula, I C; Medeiros, F S; Ushizima, D M; Cintra, L S

    2010-01-01

    This paper introduces a morphological image segmentation method by applying watershed transform with markers to scale-space smoothed images and furthermore provides images for clinical monitoring and analysis of patients. The database comprises sagittal plane images taken from a digital camera of patients submitted to Global Postural Reeducation (GPR) physiotherapy treatment. Orthopaedic specialists can use these segmented images to diagnose posture problems, assess physiotherapy treatment evolution and thus reduce diagnostic errors due to subjective analysis.

  15. Ellis-van Creveld Syndrome with Sagittal Craniosynostosis.

    Science.gov (United States)

    Fischer, Andrew S; Weathers, William M; Wolfswinkel, Erik M; Bollo, Robert J; Hollier, Larry H; Buchanan, Edward P

    2015-06-01

    Ellis-van Creveld syndrome (EVC) is a rare disorder (the incidence is estimated at around 7/1,000,000) characterized by the clinical tetrad of chondrodystrophy, polydactyly, ectodermal dysplasia, and cardiac anomalies. Sagittal synostosis is characterized by a dolichocephalic head shape resulting from premature fusion of the sagittal suture. Both are rare disorders, which have never been reported together. We present a case of EVC and sagittal synostosis. We report the clinical features of a Hispanic boy with EVC and sagittal craniosynostosis who underwent cranial vault remodeling. The presentation of this patient is gone over in detail. A never before reported case of EVC and sagittal synostosis is presented in detail.

  16. Anterior cervical discectomy and fusion versus anterior cervical corpectomy and fusion for multilevel cervical spondylosis: a systematic review.

    Science.gov (United States)

    Jiang, Sheng-Dan; Jiang, Lei-Sheng; Dai, Li-Yang

    2012-02-01

    There is considerable controversy as to which technique is best option for reconstruction after multilevel anterior decompression for cervical spondylosis. The aim of this study was to compare the clinical and radiographic results and complications of anterior cervical discectomy fusion (ACDF) and anterior cervical corpectomy fusion (ACCF) in the treatment of multi-level cervical spondylosis. We reviewed and analyzed papers published from Jan 1969 to Dec 2010 regarding the comparison of ACDF and ACCF for multilevel cervical spondylosis. Statistical comparisons were made when appropriate. Twelve studies were included in this systematic review. Blood loss was greater for ACCF compared with ACDF. Similarly, the rate of graft dislodgement in ACCF was higher than that in ACDF. Nonunion rates were 18.4% for 2-level ACDF and 37.3% for 3-level ACDF, whereas nonfusion rates were 5.1% for single-level ACCF and 15.2% for 2-level ACCF. In addition, nonunion rates for three disc levels fused were much higher than that for two disc levels fused, regardless of discectomy or corpectomy. Clinical outcome was compared between ACDF and ACCF in nine studies. Of these, similar outcome was found between ACDF and ACCF in six studies, whereas three studies reported better outcome in ACCF compared with ACDF. Nonunion rates of ACDF are higher than those of ACCF for multilevel cervical spondylosis. Sometimes, clinical outcome of ACCF was better than ACDF for multilevel cervical spondylosis.

  17. A systematic review of the angular values obtained by computerized photogrammetry in sagittal plane: a proposal for reference values.

    Science.gov (United States)

    Krawczky, Bruna; Pacheco, Antonio G; Mainenti, Míriam R M

    2014-05-01

    Reference values for postural alignment in the coronal plane, as measured by computerized photogrammetry, have been established but not for the sagittal plane. The objective of this study is to propose reference values for angular measurements used for postural analysis in the sagittal plane for healthy adults. Electronic databases (PubMed, BVS, Cochrane, Scielo, and Science Direct) were searched using the following key words: evaluation, posture, photogrammetry, and software. Articles published between 2006 and 2012 that used the PAS/SAPO (postural assessment software) were selected. Another inclusion criterion was the presentation of, at least, one of the following measurements: head horizontal alignment, pelvic horizontal alignment, hip angle, vertical alignment of the body, thoracic kyphosis, and lumbar lordosis. Angle samples of the selected articles were grouped 2 by 2 in relation to an overall average, which made possible total average, variance, and SD calculations. Six articles were included, and the following average angular values were found: 51.42° ± 4.87° (head horizontal alignment), -12.26° ± 5.81° (pelvic horizontal alignment), -6.40° ± 3.86° (hip angle), and 1.73° ± 0.94° (vertical alignment of the body). None of the articles contained the measurements for thoracic kyphosis and lumbar lordosis. The reference values can be adopted as reference for postural assessment in future researches if the same anatomical points are considered. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  18. PARAMETERS FOR THE EVALUATION OF CERVICAL SAGITTAL BALANCE IN IDIOPATHIC SCOLIOSIS

    Directory of Open Access Journals (Sweden)

    MAURICIO COELHO LIMA

    Full Text Available ABSTRACT Objective: There are no values defined as standard in the literature for the parameters of assessment of cervical sagittal balance in patients with idiopathic scoliosis. This study describes the sagittal cervical parameters in patients with idiopathic scoliosis. Methods: Study carried out in a tertiary public hospital in patients with adolescent idiopathic scoliosis, through the evaluation of panoramic radiographs in lateral view. The Cobb method was used to evaluate cervical lordosis from C2 to C7, distance from the center of gravity (COG of the skull to C7, measurement of T1 slope, thoracic inlet angle (TIA, neck tilt, and plumb line from C7 to S1 (SVA C7-S1. A statistical analysis was performed, to demonstrate the relationship between the alignment of the thoracic spine in the sagittal plane and the cervical sagittal balance of patients with scoliosis. Results: Thirty-four patients were female (69.4% and 15 male (30.6%. The mean values for COG-C7 were 0.71 mm (median 0.8 mm/standard deviation [SD]= 0.51 mm. For Cobb C2-C7, the mean was -11.7° (median -10°/SD= 20.4°. The mean slope of T1 was 23.5° (median 25°/SD= 9.5°. The mean cervical version was 58.8° (median 60°/DP= 15.4°. The mean TIA was 81.8° (median 85°/SD= 16.7°. The mean plumb line C7-S1 was -0.28 (-0.3/SD= 1.0. Conclusion: The analysis of the results showed that the mean values for the cervical lordosis are lower than the values described as normal in the literature, suggesting a loss of sagittal cervical balance in these patients.

  19. Is Cervical Sagittal Imbalance a Risk Factor for Adjacent Segment Pathomechanics After Multilevel Fusion?

    Science.gov (United States)

    Patwardhan, Avinash G; Khayatzadeh, Saeed; Nguyen, Ngoc-Lam; Havey, Robert M; Voronov, Leonard I; Muriuki, Muturi G; Carandang, Gerard; Smith, Zachary A; Sears, William; Lomasney, Laurie M; Ghanayem, Alexander J

    2016-05-01

    A biomechanical study using human spine specimens. The aim of this study was to assess whether the presence of cervical sagittal imbalance is an independent risk factor for increasing the mechanical burden on discs adjacent to cervical multilevel fusions. The horizontal offset distance between the C2 plumbline and C7 vertebral body (C2-C7 Sagittal Vertical Axis (SVA)) or the angle made with vertical by a line connecting the C2 and C7 vertebral bodies (C2-C7 tilt angle) are used as radiographic measures to assess cervical sagittal balance. There is level III clinical evidence that sagittal imbalance caused by kyphotic fusions or global spinal sagittal malalignment may increase the risk of adjacent segment pathology. Thirteen human cadaveric cervical spines (Occiput-T1; age: 50.6 years; range: 21-67) were tested first in the native intact state and then after instrumentation across C4-C6 to simulate in situ two-level fusion. Specimens were tested using a previously validated experimental model that allowed measurement of spinal response to prescribed imbalance. The effects of fusion on segmental angular alignments and intradiscal pressures in the C3-C4 and C6-C7 discs, above and below the fusion, were evaluated at different magnitudes of C2-C7 tilt angle (or C2-C7 SVA). When compared with the pre-fusion state, in situ fusion across C4-C6 segments required increased flexion angulation and resulted in increased intradiscal pressure at the C6-C7 disc below the fusion in order to accommodate the same increase in C2-C7 tilt angle or C2-C7 SVA (P adjacent segment mechanical burden due to fusion became greater with increasing C2-C7 tilt angle or SVA. Cervical sagittal imbalance arising from regional and/or global spinal sagittal malalignment may play a role in exacerbating adjacent segment pathomechanics after multilevel fusion and should be considered during surgical planning. N/A.

  20. Influence of postoperative sagittal balance and spinopelvic parameters on the outcome of patients surgically treated for degenerative lumbar spondylolisthesis.

    Science.gov (United States)

    Radovanovic, Ingrid; Urquhart, Jennifer C; Ganapathy, Venkat; Siddiqi, Fawaz; Gurr, Kevin R; Bailey, Stewart I; Bailey, Christopher S

    2017-04-01

    OBJECTIVE The object of this study was to determine the association between postoperative sagittal spinopelvic alignment and patient-rated outcome measures following decompression and fusion for lumbar degenerative spondylolisthesis. METHODS The authors identified a consecutive series of patients who had undergone surgery for lumbar degenerative spondylolisthesis between 2008 and 2012, with an average follow-up of 3 years (range 1-6 years). Surgery was performed to address the clinical symptoms of spinal stenosis, not global sagittal alignment. Sagittal alignment was only assessed postoperatively. Patients were divided into 2 groups based on a postoperative sagittal vertical axis (SVA) spondylolisthesis (p = 0.044), spondylolisthesis at the L3-4 level (p = 0.046), and multiple levels treated with fusion (p = 0.028) were more common among patients in the group with an SVA ≥ 50 mm. Patients with an SVA ≥ 50 mm had a worse SF-36 physical component summary (PCS) score (p = 0.018), a worse Oswestry Disability Index (ODI; p = 0.043), and more back pain (p = 0.039) than those with an SVA spondylolisthesis and multilevel fusion. The spinopelvic parameters differing between the < 50-mm and ≥ 50-mm groups included lumbar lordosis (LL; 56.4° ± 4.7° vs 49.8° ± 4.3°, respectively, p = 0.040) and LL < pelvic incidence ± 9° (51% vs 23.1%, respectively, p = 0.013) after controlling for type of surgical procedure. CONCLUSIONS Data in this study revealed that patient-rated outcome is influenced by the overall postoperative sagittal balance as defined by the SVA.

  1. Sagittal crest formation in great apes and gibbons.

    Science.gov (United States)

    Balolia, Katharine L; Soligo, Christophe; Wood, Bernard

    2017-06-01

    The frequency of sagittal crest expression and patterns of sagittal crest growth and development have been documented in hominoids, including some extinct hominin taxa, and the more frequent expression of the sagittal crest in males has been traditionally linked with the need for larger-bodied individuals to have enough attachment area for the temporalis muscle. In the present study, we investigate sagittal cresting in a dentally mature sample of four hominoid taxa (Pan troglodytes schweinfurthii, Gorilla gorilla gorilla, Pongo pygmaeus pygmaeus and Hylobates lar). We investigate whether sagittal crest size increases with age beyond dental maturity in males and females of G. g. gorilla and Po. pyg. pygmaeus, and whether these taxa show sex differences in the timing of sagittal crest development. We evaluate the hypothesis that the larger sagittal crest of males may not be solely due to the requirement for a larger surface area than the un-crested cranial vault can provide for the attachment of the temporalis muscle, and present data on sex differences in temporalis muscle attachment area and sagittal crest size relative to cranial size. Gorilla g. gorilla and Po. pyg. pygmaeus males show significant relationships between tooth wear rank and sagittal crest size, and they show sagittal crest size differences between age groups that are not found in females. The sagittal crest emerges in early adulthood in the majority of G. g. gorilla males, whereas the percentage of G. g. gorilla females possessing a sagittal crest increases more gradually. Pongo pyg. pygmaeus males experience a three-fold increase in the number of specimens exhibiting a sagittal crest in mid-adulthood, consistent with a secondary growth spurt. Gorilla g. gorilla and Po. pyg. pygmaeus show significant sex differences in the size of the temporalis muscle attachment area, relative to cranial size, with males of both taxa showing positive allometry not shown in females. Gorilla g

  2. Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty.

    Science.gov (United States)

    Maderbacher, Günther; Matussek, Jan; Keshmiri, Armin; Greimel, Felix; Baier, Clemens; Grifka, Joachim; Maderbacher, Hermann

    2018-02-17

    Intramedullary rods are widely used to align the distal femoral cut in total knee arthroplasty. We hypothesised that both coronal (varus/valgus) and sagittal (extension/flexion) cutting plane are affected by rotational changes of intramedullary femoral alignment guides. Distal femoral cuts using intramedullary alignment rods were simulated by means of a computer-aided engineering software in 4°, 6°, 8°, 10°, and 12° of valgus in relation to the femoral anatomical axis and 4° extension, neutral, as well as 4°, 8°, and 12° of flexion in relation to the femoral mechanical axis. This reflects the different angles between anatomical and mechanical axis in coronal and sagittal planes. To assess the influence of rotation of the alignment guide on the effective distal femoral cutting plane, all combinations were simulated with the rod gradually aligned from 40° of external to 40° of internal rotation. Rotational changes of the distal femoral alignment guides affect both the coronal and sagittal cutting planes. When alignment rods are intruded neutrally with regards to sagittal alignment, external rotation causes flexion, while internal rotation causes extension of the sagittal cutting plane. Simultaneously the coronal effect (valgus) decreases resulting in an increased varus of the cutting plane. However, when alignment rods are intruded in extension or flexion partly contradictory effects are observed. Generally the effect increases with the degree of valgus preset, rotation and flexion. As incorrect rotation of intramedullary alignment guides for distal femoral cuts causes significant cutting errors, exact rotational alignment is crucial. Coronal cutting errors in the distal femoral plane might result in overall leg malalignment, asymmetric extension gaps and subsequent sagittal cutting errors.

  3. Evaluation of the Results of Posterior Decompression, Corpectomy and Instrumentation in Traumatic Unstable Thoraco-Lumbar Burst Fractures

    Directory of Open Access Journals (Sweden)

    Md. Anowarul Islam

    2012-06-01

    Full Text Available Background: Thoraco-lumbar burst fractures occur as a result of axial load which often causes displacement of the middle column into the vertebral canal. Posterior surgery reduces the morbid outcomes of different other approaches. Objective: To evaluate the clinical and radiological success of posterior corpectomy and instrumentation in the management of traumatic unstable thoraco-lumbar burst fractures. Methods: It is a prospective interventional study carried out in Bangabandhu Sheikh Mujib Medical University and different private hospitals in Dhaka from July 2008 to December 2011. Total 18 patients; 13 male and 05 female within an age range of 21-40 years were selected. Total 09 cases involved L1, 05 cases at D12, 02 cases at D11 and at L2 each. Neurological status was assessed by Frankel‘s grading and pain status by Visual Analogue Score (VAS. Paired t-test was used for statistical analysis. Results: All the patients were followed up for minimum 1 year. Eleven out of 12 patients with Frankel grade-B and 04 patients out of 06 with Frankel grade-C recovered fully and could walk without support (p<0.05. Overall 03 patients ended with some degrees of persistant neurological deficit. The mean postoperative pain improvement and kyphotic angle correction was significant  (p<0.05. Conclusion: Decompression through posterior approach by laminectomy, corpectomy and fusion by cage with bone graft and stabilization by pedicle screw and rod significantly improves the clinical and radiological outcome in management of traumatic unstable thoraco-lumbar burst fractures.DOI: http://dx.doi.org/10.3329/bsmmuj.v5i1.10998 BSMMU J 2012; 5(1:35-41 

  4. CORRELATION BETWEEN OBESITY, SAGITTAL BALANCE AND CLINICAL OUTCOME IN SPINAL FUSION

    Directory of Open Access Journals (Sweden)

    Marcel Machado da Motta

    2015-09-01

    Full Text Available Objective:To correlate obesity with radiographic parameters of spinal and spinopelvic balance in patients undergoing spinal arthrodesis, and to correlate obesity with clinical outcome of these patients.Methods:Observational retrospective study including patients who underwent spinal arthrodesis, with minimum follow-up period of three months. We measured waist circumference, as well as height and weight to calculate body mass index (BMI and obtained radiographs of the total column. The clinical parameters studied were pain by visual analog scale (VAS and the Oswestry questionnaire (ODI. Obesity correlated with radiographic parameters of the sagittal and spinopelvic balance and postoperative clinical parameters.Results:32 patients were analyzed. The higher the BMI, the greater the value of VAS found, but without statistical significance (p=0.83. There was also no correlation between BMI and the ODI questionnaire. Analyzing the abdominal circumference, there was no correlation between the VAS and ODI. There was no correlation between BMI or waist circumference and the radiographic parameters of global spinopelvic sagittal alignment. Regarding the postoperative results, there was no correlation between the mean BMI and waist circumference and the postoperative results for ODI and VAS (p=0.75 and p=0.7, respectively.Conclusions:The clinical outcomes of patients who undergone spinal fusion were not affected by the BMI and waist circumference. Also, there was no correlation between radiographic parameters of spinal and spinopelvic sagittal balance with obesity in patients previously treated with arthrodesis of the spine.

  5. Sagittal synostosis: I. Preoperative morphology of the skull

    DEFF Research Database (Denmark)

    Guimaraes-Ferreira, J.; Gewalli, F.; David, L.

    2006-01-01

    The aim of this study was to characterise the preoperative morphology of the skull in sagittal synostosis in an objective and quantified way. The shapes of the skulls of 105 patients with isolated premature synostosis of the sagittal suture ( SS group) were studied and compared with those of a co...

  6. Superior sagittal sinus thrombosis: a rare complication of nephrotic syndrome.

    Directory of Open Access Journals (Sweden)

    Tullu M

    1999-10-01

    Full Text Available A two and half year-old-male child, known case of steroid responsive nephrotic syndrome presented with fever and vomiting of acute onset. He was diagnosed to have superior sagittal sinus thrombosis on a contrast computerised tomographic scan of brain. Recovery was complete without anticoagulant therapy. Superior sagittal sinus thrombosis is an extremely rare complication of nephrotic syndrome.

  7. Craniotomy of the Fused Sagittal Suture Over the Superior Sagittal Sinus Is a Safe Procedure.

    Science.gov (United States)

    Kölby, David; Fischer, Sara; Arab, Khalid; Maltese, Giovanni; Olsson, Robert; Paganini, Anna; Tarnow, Peter; Kölby, Lars

    2017-05-01

    Spring-assisted cranioplasty to correct sagittal synostosis is based on midline craniotomy through the closed sagittal suture, over the superior sagittal sinus (SSS). The aim of the present study was to evaluate the perioperative safety of this technique. This is a retrospective study of all patients operated with median craniotomy and springs from 1998 to the end of 2015. For comparison, all Pi-plasties performed during the same time interval were also evaluated. The safety measures were evaluated based on incidence of damage to SSS, incidence of dural tears, perioperative blood loss, operative time, and hospital stay. In the group that had undergone midline craniotomy combined with springs (n = 225), 4 perioperative damages to SSS and 1 dural tear were seen. The perioperative blood loss was 62.8 ± 65.3 mL (mean ± standard deviation). The operative time was 67.9 ± 21.5 minutes and the hospital stay was 4.8 ± 1.1 days. In the group that had undergone pi-plasty (n = 105), no damages to SSS but 3 dural tears were seen. The perioperative blood loss was 352.8 ± 174.4 mL. The operative time was 126.0 ± 31.7 minutes and the hospital stay was 7.1 ± 1.4 days. Craniotomy SSS in sagittal synostosis is a safe procedure with low morbidity in terms of damage to the SSS. Midline craniotomy combined with springs has significantly lower preoperative blood loss, operative time, and hospital stay (P < 0.001 for all) compared to pi-plasty.

  8. Corpectomy in destructive thoracolumbar spine disease: Cost-effectiveness of 3 different techniques and implications for cost reduction of delivered care.

    Science.gov (United States)

    Archavlis, Eleftherios; Papadopoulos, Nikos; Ulrich, Peter

    2015-04-01

    Retrospective cohort study. To give some insight in balancing cost and effectiveness of 3 different techniques of corpectomy in destructive thoracolumbar spine disease. Although there are several accepted methods of surgical treatment of single-level corpectomy in destructive metastatic thoracolumbar spine disease, the choice depends on the surgeon's preference. The techniques may vary in perioperative morbidity and short- and long-term outcome, but no study so far has analyzed their cost-effectiveness. Seventy-five consecutive patients, mean age of 57 years (range: 39-72 yr) with single-level destructive thoracolumbar lesion underwent surgical treatment with 3 different techniques in 2 centers from 2009 to 2013. The 3 groups were (1) mini open transpedicular corpectomy, (2) conventional open transpedicular corpectomy, and (3) the combined posterior-anterior approach. The data were collected prospectively according to our protocol and subsequently analyzed. The clinical outcome was assessed comparing visual analogue scale score of back pain and the short form 12 (SF-12) questionnaire both pre- and postoperatively. The cost analysis was done calculating the operative time, hospital stay, and the implant cost. The mean follow-up period was 25 months (range: 24-30 mo). The clinical outcome in terms of visual analogue scale score of thoracolumbar pain and SF-12 physical and mental score improvement (P < 0.005) were comparable with all 3 techniques. The radiological outcome was comparable with current available data. As the intensive care unit stay (average: 7 d) and the hospital stay were longer (average: 15 d) with combined posterior-anterior approach, the total cost was maximum (average: €20,952) with this group. Using the posterior approach only was the most cost-effective technique, but the mini open was comparable with the conventional open transpedicular approach. 3.

  9. Sagittal standing posture and its association with spinal pain: a school-based epidemiological study of 1196 Flemish adolescents before age at peak height velocity.

    Science.gov (United States)

    Dolphens, Mieke; Cagnie, Barbara; Coorevits, Pascal; Vanderstraeten, Guy; Cardon, Greet; Dʼhooge, Roseline; Danneels, Lieven

    2012-09-01

    Cross-sectional baseline data set on the sagittal standing posture of 1196 adolescents. To describe and quantify common variations in the sagittal standing alignment in boys and girls who are in the same phase of growth and to explore the association between habitual standing posture and measures for spinal pain. Data on postural characteristics and spinal pain measures in adolescence are sparse, especially when somatic and biological maturity status is to be considered. Our understanding of the relationship between standing posture in the sagittal plane and spinal pain is also deficient. A total of 639 boys (age [mean ± SD], 12.6 ± 0.54 yr) and 557 girls (10.6 ± 0.47 yr), with predicted years from peak height velocity (PHV) being 1.2 ± 0.71 and 1.2 ± 0.59 pre-PHV, respectively, were studied. Postural examination included the assessment of global alignment and local spinopelvic characteristics, using post hoc analyses of digital images and direct body measurements (palpation, digital inclinometry, and wheeled accelerometry). Spinal pain experience was assessed by questionnaire. A wide interindividual variation in sagittal posture characteristics was observed. Logistic regression analyses yielded global alignment parameters to be associated with low back pain (lifetime prevalence), neck pain (lifetime prevalence, 1-mo prevalence, and doctor visit), and thoracic spine pain (doctor visit) outcome measures. None of the included local spinopelvic parameters could be identified as an associated factor with measures of spinal pain. The orientation of gross body segments with respect to the gravity line seems superior to local spinopelvic features in terms of clinical importance, at least in the current pre-PHV cohort. Opportunities may exist for postural subgrouping strategies to begin with global alignment parameters in order to gain further insight into the relationship between sagittal alignment and the relative risk of developing spinal pain/seeking medical

  10. Individual and contextual characteristics as determinants of sagittal standing posture: a population-based study of adults.

    Science.gov (United States)

    Araújo, Fábio; Lucas, Raquel; Alegrete, Nuno; Azevedo, Ana; Barros, Henrique

    2014-10-01

    Sagittal standing posture is associated with musculoskeletal symptoms and quality of life. However, the frequency and determinants of suboptimal sagittal alignment outside the clinical context remain to be clarified. To estimate the association of sociodemographic, anthropometric, and behavioral characteristics with sagittal standing posture among adults from the general population. Cross-sectional evaluation of a population-based sample. As part of the EPIPorto study, 489 adults were assessed during 2005 to 2008. Individual spinopelvic parameters were measured. Additionally, participants were classified into one of four types of sagittal postural patterns (Roussouly classification: Types 1, 2, and 4 corresponding to nonneutral postures and Type 3 to a neutral posture). Spinopelvic parameters were recorded from 36-inch sagittal radiographs obtained in free-standing posture. Age, sex, education, occupation, body mass index (BMI), waist circumference, total physical activity, leisure time physical activity, time spent in sitting position, smoking status, and tobacco cumulative exposure were collected. Individual parameters and patterns of sagittal posture were compared across categories of participants' characteristics. Older age, lower educational level, blue collar occupation, and overall and central obesity were associated with increased sagittal vertical axis and pelvic tilt/pelvic incidence ratio. Taking the neutral postural pattern (Type 3) as reference for the outcome in a multinomial regression model, independently of age, sex, education, total physical activity, and smoking status, overweight adults had higher odds of Type 2 (odds ratio [OR]=1.92; 95% confidence interval [CI]: 1.13-3.27) and Type 4 (OR=2.13; 95% CI: 1.16-3.91) postural patterns in comparison with normal weight subjects. Overall and central obesity were positively related with Type 1 postural pattern (OR=6.10, 95% CI: 1.52-24.57 and OR=3.54, 95% CI: 1.13-11.11, respectively). There was also a

  11. Sagittal Abdominal Diameter: Application in Clinical Practice

    Directory of Open Access Journals (Sweden)

    Thaís Da Silva-Ferreira

    2014-05-01

    Full Text Available Excess visceral fat is associated with cardiovascular risk factors. Sagittal abdominal diameter (SAD has recently been highlighted as an indicator of abdominal obesity, and also may be useful in predicting cardiovascular risk. The purpose of the present study was to review the scientific literature on the use of SAD in adult nutritional assessment. A search was conducted for scientific articles in the following electronic databases: SciELO , MEDLINE (PubMed and Virtual Health Library. SAD is more associated with abdominal fat (especially visceral, and with different cardiovascular risk factors, such as, insulin resistance, blood pressure, and serum lipoproteins than the traditional methods of estimating adiposity, such as body mass index and waist-to-hip ratio. SAD can also be used in association with other anthropometric measures. There are still no cut-off limits established to classify SAD as yet. SAD can be an alternative measure to estimate visceral adiposity. However, the few studies on this diameter, and the lack of consensus on the anatomical site to measure SAD, are obstacles to establish cut-off limits to classify it.

  12. [Biomechanic principles of the sagittal compensating curve].

    Science.gov (United States)

    Kubein-Meesenburg, D; Nägerl, H; Fanghänel, J

    1990-07-01

    The alignment of the buccal teeth along the compensating curve is of functional importance. It is closely related with the functional gear system of anterior and posterior guidance. Measurements have shown that individual differences between masticatory systems are mainly attributable to functional parameters. Purely skeletal parameters are of comparatively little variability. The compensating curve may be regarded as a guiding element within a master gear systems which includes the gear system of anterior and posterior guidance.

  13. Non-structural misalignments of body posture in the sagittal plane.

    Science.gov (United States)

    Czaprowski, Dariusz; Stoliński, Łukasz; Tyrakowski, Marcin; Kozinoga, Mateusz; Kotwicki, Tomasz

    2018-01-01

    The physiological sagittal spinal curvature represents a typical feature of good body posture in the sagittal plane. The cervical and the lumbar spine are curved anteriorly (lordosis), while the thoracic segment is curved posteriorly (kyphosis). The pelvis is inclined anteriorly, and the lower limbs' joints remain in a neutral position. However, there are many deviations from the optimal body alignment.The aim of this paper is to present the most common types of non-structural misalignments of the body posture in the sagittal plane. The most common types of non-structural misalignments of body posture in the sagittal plane are as follows: (1) lordotic, (2) kyphotic, (3) flat-back, and (4) sway-back postures. Each one may influence both the skeletal and the muscular system leading to the functional disturbance and an increased strain of the supporting structures. Usually, the disturbances localized within the muscles are analyzed in respect to their shortening or lengthening. However, according to suggestions presented in the literature, when the muscles responsible for maintaining good body posture (the so-called stabilizers) are not being stimulated to resist against gravity for an extended period of time, e.g., during prolonged sitting, their stabilizing function is disturbed by the hypoactivity reaction resulting in muscular weakness. The deficit of the locomotor system stability triggers a compensatory mechanism-the stabilizing function is overtaken by the so-called mobilizing muscles. However, as a side effect, such compensation leads to the increased activity of mobilizers (hyperactivity) and decreased flexibility, which may finally lead to the pathological chain of reaction within the musculoskeletal system. There exist four principal types of non-structural body posture misalignments in the sagittal plane: lordotic posture, kyphotic posture, flat-back posture, and sway-back posture. Each of them can disturb the physiological loading of the musculoskeletal

  14. Self-Inflicted Drywall Screws in the Sagittal Sinus.

    Science.gov (United States)

    Guppy, Kern H; Ochi, Calvin

    2018-02-01

    A 30-year-old right-handed man with a history of schizophrenia presented with 2 self-inflicted drywall screws in the skull. The patient was sleepy but easily arousable; blood tests showed he had taken methamphetamines. Computed tomography and computed tomography angiography of the head showed the frontal screw abutted left of the superior sagittal sinus, and the posterior screw went through the superior sagittal sinus with no extravasation of contrast material at either site. Both screws were removed with exposure of the sagittal sinus using U-shaped craniectomies. There was no bleeding on the removal of the screws. It appears the posterior screw entered between the leaflets of the sagittal sinus dura mater. The patient had returned to work without any sequelae 1 month after injury. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Measurement accuracy of condylar position on reformatted sagittal CT and sagittal tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hiruma, Takayoshi [Showa Univ., Tokyo (Japan). School of Dentistry

    1995-12-01

    The purpose of this study was to compare the measurement accuracy of the condylar position on reformatted sagittal CT with that on sagittal tomography (TG). The CTs were reformatted from the 1 mm thickness/interval coronal scan. The TGs were performed with hypocycloidal motion. Impressions of the joint space were taken in order to estimate the actual dimensions. The errors, differences between the values from the impressions and the values from CTs and TGs, were calculated and analyzed by ANOVA. The results were as follows: The mean measurement error of the condylar position on the CT was 0.1 mm. No statistically significant differences were observed among the CTs reformatted from the coronal scan obtained with the X-ray beam projecting at 90deg, 80deg and 70deg to the F-H plane. The measurement error on the TGs with a mean value of 0.3 mm was larger than that of the CTs. However, one of the 6 TMJs caused a great measurement error on the TG with a mean value of 0.9 mm while the measurement of the other 5 TMJs showed a smaller mean error of 0.1 mm. These findings suggest that the anatomic morphology of TMJs influence the measurement accuracy on the TGs. (author).

  16. CHANGES IN THE SAGITTAL BALANCE IN CONGENITAL SCOLIOSIS CORRECTION SURGERY

    OpenAIRE

    Mancuso Filho, José Antonio; Borges, Paulo Alvim; Tsuchiya, Eduardo Hideo; Letaif, Olavo Biraghi; Marcon, Raphael Martus; Cristante, Alexandre Fogaça

    2016-01-01

    ABSTRACT Objective: This study aimed to determine whether surgery leads to changes in sagittal balance in patients with congenital scoliosis. Methods: We retrospectively reviewed all cases of scoliosis operated in a tertiary hospital between January 2009 and January 2013. In all cases the deformity in the coronal and sagittal planes, kyphosis, and lordosis were measured, using the Cobb method, and spinopelvic parameters: pelvic incidence (PI), sacral slope (SS), and pelvic tilt (PT). Resul...

  17. Alignment validation

    Energy Technology Data Exchange (ETDEWEB)

    ALICE; ATLAS; CMS; LHCb; Golling, Tobias

    2008-09-06

    The four experiments, ALICE, ATLAS, CMS and LHCb are currently under constructionat CERN. They will study the products of proton-proton collisions at the Large Hadron Collider. All experiments are equipped with sophisticated tracking systems, unprecedented in size and complexity. Full exploitation of both the inner detector andthe muon system requires an accurate alignment of all detector elements. Alignmentinformation is deduced from dedicated hardware alignment systems and the reconstruction of charged particles. However, the system is degenerate which means the data is insufficient to constrain all alignment degrees of freedom, so the techniques are prone to converging on wrong geometries. This deficiency necessitates validation and monitoring of the alignment. An exhaustive discussion of means to validate is subject to this document, including examples and plans from all four LHC experiments, as well as other high energy experiments.

  18. Factors influencing spinal sagittal balance, bone mineral density, and Oswestry Disability Index outcome measures in patients with rheumatoid arthritis.

    Science.gov (United States)

    Masamoto, Kazutaka; Otsuki, Bungo; Fujibayashi, Shunsuke; Shima, Koichiro; Ito, Hiromu; Furu, Moritoshi; Hashimoto, Motomu; Tanaka, Masao; Lyman, Stephen; Yoshitomi, Hiroyuki; Tanida, Shimei; Mimori, Tsuneyo; Matsuda, Shuichi

    2018-02-01

    To identify the factors influencing spinal sagittal alignment, bone mineral density (BMD), and Oswestry Disability Index (ODI) outcome measures in patients with rheumatoid arthritis (RA). We enrolled 272 RA patients to identify the factors influencing sagittal vertical axis (SVA). Out of this, 220 had evaluation of bone mineral density (BMD) and vertebral deformity (VD) on the sagittal plane; 183 completed the ODI questionnaire. We collected data regarding RA-associated clinical parameters and standing lateral X-ray images via an ODI questionnaire from April to December 2012 at a single center. Patients with a history of spinal surgery or any missing clinical data were excluded. Clinical parameters included age, sex, body mass index, RA disease duration, disease activity score 28 erythrocyte sedimentation rate (DAS28-ESR), serum anti-cyclic citrullinated peptide antibody, serum rheumatoid factor, serum matrix metalloproteinase-3, BMD and treatment type at survey, such as methotrexate (MTX), biological disease-modifying anti-rheumatic drugs, and glucocorticoids. We measured radiological parameters including pelvic incidence (PI), lumbar lordosis (LL), and SVA. We statistically identified the factors influencing SVA, BMD, VD, and ODI using multivariate regression analysis. Multivariate regression analysis showed that larger SVA correlated with older age, higher DAS28-ESR, MTX nonuse, and glucocorticoid use. Lower BMD was associated with female, older age, higher DAS28-ESR, and MTX nonuse. VD was associated with older age, longer disease duration, lower BMD, and glucocorticoid use. Worse ODI correlated with older age, larger PI-LL mismatch or larger SVA, higher DAS28-ESR, and glucocorticoid use. In managing low back pain and spinal sagittal alignment in RA patients, RA-related clinical factors and the treatment type should be taken into consideration.

  19. Mid-sagittal plane and mid-sagittal surface optimization in brain MRI using a local symmetry measure

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Skoglund, Karl; Ryberg, Charlotte

    2005-01-01

    , the mid-sagittal plane is not always planar, but a curved surface resulting in poor partitioning of the brain hemispheres. To account for this, this paper also investigates an optimization strategy which fits a thin-plate spline surface to the brain data using a robust least median of squares estimator....... Albeit computationally more expensive, mid-sagittal surface fitting demonstrated convincingly better partitioning of curved brains into cerebral hemispheres....

  20. Sagittal otolith morphogenesis asymmetry in marine fishes.

    Science.gov (United States)

    Mille, T; Mahe, K; Villanueva, M C; De Pontual, H; Ernande, B

    2015-09-01

    This study investigated and compared asymmetry in sagittal otolith shape and length between left and right inner ears in four roundfish and four flatfish species of commercial interest. For each species, the effects of ontogenetic changes (individual age and total body length), sexual dimorphism (individual sex) and the otolith's location on the right or left side of the head, on the shape and length of paired otoliths (between 143 and 702 pairs according to species) were evaluated. Ontogenetic changes in otolith shape and length were observed for all species. Sexual dimorphism, either in otolith shape and length or in their ontogenetic changes, was detected for half of the species, be they round or flat. Significant directional asymmetry in otolith shape and length was detected in one roundfish species each, but its inconsistency across species and its small average amplitude (6·17% for shape and 1·99% for length) suggested that it has barely any biological relevance. Significant directional asymmetry in otolith shape and length was found for all flatfish species except otolith length for one species. Its average amplitude varied between 2·06 and 17·50% for shape and between 0·00 and 11·83% for length and increased significantly throughout ontogeny for two species, one dextral and one sinistral. The longer (length) and rounder otolith (shape) appeared to be always on the blind side whatever the species. These results suggest differential biomineralization between the blind and ocular inner ears in flatfish species that could result from perturbations of the proximal-distal gradient of otolith precursors in the endolymph and the otolith position relative to the geometry of the saccular epithelium due to body morphology asymmetry and lateralized behaviour. The fact that asymmetry never exceeded 18% even at the individual level suggests an evolutionary canalization of otolith shape symmetry to avoid negative effects on fish hearing and balance. Technically

  1. Comparison of polymethylmethacrylate versus expandable cage in anterior vertebral column reconstruction after posterior extracavitary corpectomy in lumbar and thoraco-lumbar metastatic spine tumors.

    Science.gov (United States)

    Eleraky, Mohammed; Papanastassiou, Ioannis; Tran, Nam D; Dakwar, Elias; Vrionis, Frank D

    2011-08-01

    Single-stage posterior corpectomy for the management of spinal tumors has been well described. Anterior column reconstruction has been accomplished using polymethylmethacrylate (PMMA) or expandable cages (EC). The aim of this retrospective study was to compare PMMA versus ECs in anterior vertebral column reconstruction after posterior corpectomy for tumors in the lumbar and thoracolumbar spine. Between 2006 and 2009 we identified 32 patients that underwent a single-stage posterior extracavitary tumor resection and anterior reconstruction, 16 with PMMA and 16 with EC. There were no baseline differences in regards to age (mean: 58.2 years) or performance status. Differences between groups in terms of survival, estimated blood loss (EBL), kyphosis reduction (decrease in Cobb's angle), pain, functional outcomes, and performance status were evaluated. Mean overall survival and EBL were 17 months and 1165 ml, respectively. No differences were noted between the study groups in regards to survival (p = 0.5) or EBL (p = 0.8). There was a trend for better Kyphosis reduction in favor of the EC group (10.04 vs. 5.45, p = 0.16). No difference in performance status or VAS improvements was observed (p > 0.05). Seven patients had complications that led to reoperation (5 infections). PMMA or ECs are viable options for reconstruction of the anterior vertebral column following tumor resection and corpectomy. Both approaches allow for correction of the kyphotic deformity, and stabilization of the anterior vertebral column with similar functional and performance status outcomes in the lumbar and thoracolumbar area.

  2. [Results to 4-year follow-up of the treatment of the cervical stenosis by corpectomy, titanium mesh cage and anterior plate fixation].

    Science.gov (United States)

    Reyes Sánchez, Alejandro Antonio; Gameros Castañeda, Luis Alberto; Obil Chavarría, Claudia; Alpizar Aguirre, Armando; Zárate Kalfópulos, Barón; Rosales-Olivares, Luis Miguel

    Cervical spondylotic myelopathy is caused by cervical stenosis. Several techniques have been described for the treatment of multilevel disease, such as the anterior corpectomy with titanium mesh cage and anterior cervical plate placement, which has the advantage of performing a wider decompression and using the same bone as graft. However, it has caused controversy since the collapse of the mesh cage continues being a major limitation of this procedure. A prospective 4-year follow-up study was conducted in 7 patients diagnosed with cervical stenosis, who were treated surgically by one level corpectomy with titanium mesh cage and anterior cervical plate placement, evaluating them by radiographs and clinical scales. 7 patients, 5 women and 2 males were studied. The most common level was C5 corpectomy (n=4). The Neck Disability Index (NDI) preoperative average was 30.01±24.32 and 4-year postoperative 16.90±32.05, with p=0.801. The preoperative and 4-year postoperative Nürick was 3.28± 48 and 3.14±1.21 respectively, with p=0.766. Preoperative lordosis was 14.42±8.03 and 4-year postoperative 17±11.67 degrees, with p=0.660. The immediate postoperative and 4-year postoperative subsidence was 2.69±2.8 and 6.11±1.61 millimeters respectively, with p=0.0001. Despite the small sample, the subsidence of the mesh cage is common in this procedure. No statistically significant changes were observed in the lordosis or Nürick scale and NDI. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  3. Bilateral sagittal split osteotomy: Surgery first approach for correction of skeletal Class II

    Directory of Open Access Journals (Sweden)

    Revathi Peddu

    2018-01-01

    Full Text Available Most of the skeletal malocclusions which require orthognathic surgeries are treated by traditional approach which requires time-consuming and unesthetic presurgical orthodontic phase. Surgery first approach (SFA avoids these disadvantages of the traditional approach. A 24-year-old female patient with skeletal and dental class II malocclusion due to retrognathic mandible was treated with SFA. Bilateral sagittal split osteotomy with mandibular advancement was done immediately after initial alignment and closure of the existing spaces in the maxillary arch. Angle's class I molar and canine relation was achieved after surgery. Bonding of the mandibular arch was done after 1 month of orthognathic surgery and treatment was completed within 13 months. A wrap-around retainer was placed in upper arch, and bonded lingual retainer was given in the lower arch.

  4. Surgical overreduction and hyperlordotic fusion of C1-C2 joint are associated with cervical sagittal malalignment.

    Science.gov (United States)

    Huang, Ji-Chen; Qian, Bang-Ping; Qiu, Yong; Yu, Yang; Ni, Hong-Bin

    2017-12-01

    Previous studies have shown that hyperlordotic C1-C2 fusion was related to postoperative subaxial kyphosis. However, most of the patients in these studies were complicated with rheumatoid arthritis (RA). Moreover, no studies have specifically evaluated the relationship between C1-C2 fusion angle and cervical sagittal vertical axis (cSVA), T1 slope or cranial tilt (CRT) after posterior C1-C2 fusion. This study aimed to investigate the cervical sagittal alignment in non-RA patients following posterior C1-C2 fusion and the correlation between C1-C2 fusion angle and postoperative cervical sagittal alignment. From August 2004 to December 2015, twenty-eight consecutive patients with an average age of 39.2 years (range 6-70 years) who underwent posterior C1-C2 fusion from a single institution were enrolled. The mean follow-up period was 30.7 months (range 12-77 months). Angles of Oc-C1, C1-C2, C2-C3 and C2-C7, cSVA, T1 slope and CRT were measured in lateral cervical radiographs in neutral position before surgery and at the final follow-up. C1-C2 angle significantly increased from 13.6° ± 12.4° to 22.0° ± 8.1° at the final follow-up (P fusion angle was significantly associated with Oc-C1, C2-C7 angle, cSVA and CRT at the final follow-up. A significant correlation was also observed between postoperative change of C1-C2 angle and that of Oc-C1, C2-C7 angle, cSVA and CRT. Apart from decreased subaxial lordosis, posterior C1-C2 fusion in hyperextension may also lead to kyphotic change of atlanto-occipital alignment and increased tilting forward of the cervical spine. Therefore, intraoperative overreduction of C1-C2 angle and hyperlordotic C1-C2 fusion should be avoided to maintain the physiologic cervical sagittal alignment.

  5. Beyond Alignment

    DEFF Research Database (Denmark)

    Beyond Alignment: Applying Systems Thinking to Architecting Enterprises is a comprehensive reader about how enterprises can apply systems thinking in their enterprise architecture practice, for business transformation and for strategic execution. The book's contributors find that systems thinking...... is a valuable way of thinking about the viable enterprise and how to architect it....

  6. Diffraction crystals for sagittally focusing x-rays

    Science.gov (United States)

    Ice, G.E.; Sparks, C.J. Jr.

    1982-06-07

    The invention is a new type of diffraction crystal designed for sagittally focusing photons of various energies. The invention is based on the discovery that such focusing is not obtainable with conventional crystals because of distortion resulting from anticlastic curvature. The new crystal comprises a monocrystalline base having a front face contoured for sagittally focusing photons and a back face provided with rigid, upstanding, stiffening ribs restricting anticlastic curvature. When mounted in a suitable bending device, the reflecting face of the crystal can be adjusted to focus photons having any one of a range of energies.

  7. Open wound management of esophagocutaneous fistula in unstable cervical spine after corpectomy and multilevel laminectomy: A case report and review of the literature.

    Science.gov (United States)

    Elgafy, Hossein; Khan, Mustafa; Azurdia, Jacob; Peters, Nicholas

    2017-08-18

    A 67-year-old female patient developed an esophagocutaneous fistula 4 mo after C4 and C5 partial corpectomy. Plain radiograph and computed tomography (CT) scan of cervical spine showed inferior screws pullout with plate migration that caused the esophageal perforation. Management included removal of anterior hardware, revision C4-5 corpectomy, iliac crest strut autograft and halo orthosis immobilization. The fistula was treated using antibiotics and a 10-french gauge rubber tube for daily irrigation and Penrose drain. At 3 mo, the esophagocutaneous fistula healed and the patient resumed oral feeding. Six months follow-up CT scan showed sound fusion with graft incorporation. At two-year follow-up, patient denied any neck pain or dysphagia. This case report presents a successful outcome of a conservative open wound management without attempted repair. The importance of this case report is to highlight this treatment method that may be considered in such a rare complication particularly if surgical repair failed.

  8. ALIGNING JIG

    Science.gov (United States)

    Culver, J.S.; Tunnell, W.C.

    1958-08-01

    A jig or device is described for setting or aligning an opening in one member relative to another member or structure, with a predetermined offset, or it may be used for measuring the amount of offset with which the parts have previously been sct. This jig comprises two blocks rabbeted to each other, with means for securing thc upper block to the lower block. The upper block has fingers for contacting one of the members to be a1igmed, the lower block is designed to ride in grooves within the reference member, and calibration marks are provided to determine the amount of offset. This jig is specially designed to align the collimating slits of a mass spectrometer.

  9. Defending Alignment

    Directory of Open Access Journals (Sweden)

    Stephan Schwarz

    2016-05-01

    Full Text Available After the rise to power of the German National Socialist Party (January 30, 1933, German academia soon realized that a requirement for “muddling through” was to avoid the stigma of being regarded as “politically unreliable,” thus to appear aligned and loyal to the state policies. The focus is here on the physics community. A rhetoric of alignment developed with the objective to justify collaboration as a rational and morally justified strategy. In the early post-war years, the rhetoric was reoriented to deny any involvement (other than as resistance systematically using a conceptual framework foreshadowing the principles of Cognitive Dissonance Reduction (CDR and the related framework of Rhetorical (Informal Fallacies. This affinity is here studied with reference to statements from the period.

  10. Sagittal plane mal-alignment in lumbar spinal radiographs in a ...

    African Journals Online (AJOL)

    Background: Plane radiograph of the spine is still the primary or first line investigation in patients with a variety of symptoms including back pain in a resource limited setting like ours. Methods: A crosssectional study of radiographs of patients who were referred to Radiology Department of Jos University Teaching Hospital for ...

  11. Do intraoperative radiographs predict final lumbar sagittal alignment following single-level transforaminal lumbar interbody fusion?

    Science.gov (United States)

    Salem, Khalid M I; Eranki, Aditya P; Paquette, Scott; Boyd, Michael; Street, John; Kwon, Brian K; Fisher, Charles G; Dvorak, Marcel F

    2018-02-16

    OBJECTIVE The study aimed to determine if the intraoperative segmental lordosis (as calculated on a cross-table lateral radiograph following a single-level transforaminal lumbar interbody fusion [TLIF] for degenerative spondylolisthesis/low-grade isthmic spondylolisthesis) is maintained at discharge and at 6 months postsurgery. METHODS The authors reviewed images and medical records of patients ≥ 16 years of age with a diagnosis of an isolated single-level, low-grade spondylolisthesis (degenerative or isthmic) with symptomatic spinal stenosis treated between January 2008 and April 2014. Age, sex, surgical level, surgical approach, and facetectomy (unilateral vs bilateral) were recorded. Upright standardized preoperative, early, and 6-month postoperative radiographs, as well as intraoperative lateral radiographs, were analyzed for the pelvic incidence, segmental lumbar lordosis (SLL) at the TILF level, and total LL (TLL). In addition, the anteroposterior position of the cage in the disc space was documented. Data are presented as the mean ± SD; a p value level using a bullet-shaped cage. A bilateral facetectomy was performed in 17 patients (20.2%), and 89.3% of procedures were done at the L4-5 and L5-S1 segments. SLL significantly improved intraoperatively from 15.8° ± 7.5° to 20.9° ± 7.7°, but the correction was lost after ambulation. Compared with preoperative values, at 6 months the change in SLL was modest at 1.8° ± 6.7° (p = 0.025), whereas TLL increased by 4.3° ± 9.6° (p level of surgery, and use of a bilateral facetectomy did not significantly affect postoperative LL. CONCLUSIONS Following a single-level TLIF procedure using a bullet-shaped cage, the intraoperative improvement in SLL is largely lost after ambulation. The improvement in TLL over time is probably due to the decompression part of the procedure. The approach, level of surgery, bilateral facetectomy, and position of the cage do not seem to have a significant effect on LL achieved postoperatively.

  12. Image alignment

    Science.gov (United States)

    Dowell, Larry Jonathan

    2014-04-22

    Disclosed is a method and device for aligning at least two digital images. An embodiment may use frequency-domain transforms of small tiles created from each image to identify substantially similar, "distinguishing" features within each of the images, and then align the images together based on the location of the distinguishing features. To accomplish this, an embodiment may create equal sized tile sub-images for each image. A "key" for each tile may be created by performing a frequency-domain transform calculation on each tile. A information-distance difference between each possible pair of tiles on each image may be calculated to identify distinguishing features. From analysis of the information-distance differences of the pairs of tiles, a subset of tiles with high discrimination metrics in relation to other tiles may be located for each image. The subset of distinguishing tiles for each image may then be compared to locate tiles with substantially similar keys and/or information-distance metrics to other tiles of other images. Once similar tiles are located for each image, the images may be aligned in relation to the identified similar tiles.

  13. Intra-operative complications in sagittal and vertical ramus osteotomies

    NARCIS (Netherlands)

    van Merkesteyn, J. P.; Groot, R. H.; van Leeuwaarden, R.; Kroon, F. H.

    1987-01-01

    In orthognatic surgery of the mandibular ramus, intra-operative complications as a lesion of the inferior alveolar nerve, fractures of the osteotomised segments, incomplete sectioning, malpositioning of segments and haemorrhage may occur. In this report, intra-operative complications in 124 sagittal

  14. Lenke 1 and 5: changes in sagittal balance

    Directory of Open Access Journals (Sweden)

    Delson Valdemir Pessin

    2014-09-01

    Full Text Available OBJECTIVE: To assess in a cross-sectional study whether there are changes in sagittal balance in patients with adolescent idiopathic scoliosis Lenke types 1 and 5 compared with patients without pathology of the spine and compare the values of the parameters of normal subjects with the parameters found in the literature. METHODS: We measured the values of the parameters of sagittal balance of 21 patients with scoliosis and 14 patients without scoliosis in panoramic radiographs or simply collected data previously measured from the medical records. We compared the mean values of normal subjects, the mean values found in the literature, and the means between normal subjects and patients with scoliosis. For this, we used the Student t test. RESULTS: Using a confidence interval of 5% (p < 0.05 and the Student t test we obtained statistical significance in the comparison of two parameters of sagittal balance between normal subjects and patients with scoliosis. We observed similarities in the measurements of the average parameters of normal subjects with regard to the work already published. CONCLUSIONS: The adolescent idiopathic scoliosis causes changes in two parameters of sagittal balance with statistical significance but suggests changes in all other parameters. As for comparison with previously published work, the results were similar.

  15. Distraction Osteogenesis Technique for the Treatment of Nonsyndromic Sagittal Synostosis

    OpenAIRE

    Johns, Dana; Blagg, Ross; Kestle, John R. W.; Riva-Cambrin, Jay K.; Siddiqi, Faizi; Gociman, Barbu

    2015-01-01

    Background Historically, surgical treatment of children with a delayed presentation of cranial synostosis required complex cranial vault reconstruction. Recently, less invasive options for surgical correction, such as internal distraction osteogenesis, have been explored. In this study, we describe the successful management of delayed presentation of sagittal synostosis using distraction osteogenesis. Methods A bicoronal incision was made and 2 large rectangular osteotomies were performed bil...

  16. A morphological description of the sagittal otoliths of two mormyrids ...

    African Journals Online (AJOL)

    The morphology of the sagittal otoliths of two South African mormyrid fish, Marcusenius macrolepidotus and Petrocephalus catostoma, were studied to determine possible morphological significance. The sagittae of M. macrolepidotus and P. catostoma are kidney-shaped and oblong, respectively. The ventral margin is ...

  17. [The clinical value of end plate rings in preventing subsidence of titanium cage in anterior cervical corpectomy and fusion surgery].

    Science.gov (United States)

    He, Lei; Qian, Yu; Jin, Yi-Jun; Fan, Liang; Lü, Zuo

    2014-09-01

    To evaluate the clinical results of using end plate rings in preventing subsidence of titanium cage in anterior cervical corpectomy and fusion (ACCF) surgery. The clinical data of 71 patients with cervical spondylotic myelopathy underwent ACCF in single segment from February 2008 to February 2011 were retrospectively analyzed. There were 38 males and 33 females, aged from 39 to 74 years old with a mean of 53.8 years. Thirty-three were used end plate rings and thirty-eight were not used (end plate rings group and no end plate ring group, respectively). The Japanese Orthopaedic Association (JOA) score, Odom's scale, imaging data were used to evaluate the clinical effects. Imaging data including Cobb angle of fusion segment, intervertebral height of anterior border (Da) and posterior border (Dp), the mean intervertebral height (Dm). All patients were followed up from 13 to 34 months with an average of 19.5 months. Between two groups, there was no significant difference in Cobb angle of fusion segment and the mean intervertebral height (Dm) before surgery and one week after surgery. Whereas, one year after surgery, the Cobb angle of end plate ring group was (9.4 ± 3.8) degrees, and contral group was (7.5 ± 3.9) degrees, which was significantly lower than that of end plate ring group. Meanwhile, the Dm of end plate ring group was (57.3 ± 2.2) mm, and no end ring group was (55.2 ± 2.6) mm which was significantly lower than that of end plate ring group. The subsidence in end plate ring group was 57.6%, and was 78.9% in no end plate ring group. There was no significant difference in JOA score before and after surgery between two groups. At 1 year after operation, 90.9% (30/33) got excellent or good results in end plate ring group, 89.5% (33/38) got excellent or good results in contral group. The use of end plate rings could not completely prevent the subsidence of titanium cage, however, which can decrease the occurrence rate of the subsidence and lessen its degree.

  18. REPRODUCIBILITY AND EQUIVALENCE OF COBBMETER APPLICATION IN THE SAGITTAL EVALUATION OF THE SPINE

    Directory of Open Access Journals (Sweden)

    Luis Marchi

    Full Text Available ABSTRACT Objective: This study aims to evaluate the reliability and equivalency of using the Cobbmeter application for iPhone compared to the manual measurement method in the analysis of the sagittal spinal alignment. Methods: Cross-sectional, prospective, single-center study that had 20 panoramic radiographs of the spine in lateral view, in a neutral standing position, analyzed blindly and randomly by three independent examiners in three different times. The parameters were pelvic incidence (PI, pelvic tilt (PT and lumbar lordosis (LL. The statistical analysis was performed to measure the intraclass correlation coefficient (ICC between the two measurement methods, in addition to measuring the intra and inter-evaluators reliability. Results: For reproducibility analysis, the intra-evaluators ICC using the application resulted in a Kappa (K of 0.975 for the evaluation of pelvic incidence (PI evaluation. For pelvic tilt (PT, the K value obtained was 0.981 and the K measured for lumbar lordosis (LL analysis was 0.987. The inter-evaluators evaluation of reproducibility using the application resulted in a K value of 0.917 for PI, 0.930 for PT and 0.951 for LL. For the assessment of equivalency of methods, comparing the application to the standard method, with a goniometer and dermographic pencil, the K value found for PI was 0.873, for PV was 0.939 and for LL was 0.914. All values were significant (p<0.001 against the null hypothesis. Conclusion: This smartphone application is a valid and reliable instrument for measuring the angle involved in the sagittal balance of the spine. Furthermore, the results show that its applicability is not inferior to the manual method with goniometer and dermographic pencil.

  19. Non-radiographic methods of measuring global sagittal balance: a systematic review.

    Science.gov (United States)

    Cohen, Larry; Kobayashi, Sarah; Simic, Milena; Dennis, Sarah; Refshauge, Kathryn; Pappas, Evangelos

    2017-01-01

    Global sagittal balance, describing the vertical alignment of the spine, is an important factor in the non-operative and operative management of back pain. However, the typical gold standard method of assessment, radiography, requires exposure to radiation and increased cost, making it unsuitable for repeated use. Non-radiologic methods of assessment are available, but their reliability and validity in the current literature have not been systematically assessed. Therefore, the aim of this systematic review was to synthesise and evaluate the reliability and validity of non-radiographic methods of assessing global sagittal balance. Five electronic databases were searched and methodology evaluated by two independent reviewers using the13-item, reliability and validity, Brink and Louw critical appraisal tool. Fourteen articles describing six methodologies were identified from 3940 records. The six non-radiographic methodologies were biophotogrammetry, plumbline, surface topography, infra-red motion analysis, spinal mouse and ultrasound. Construct validity was evaluated for surface topography ( R  = 0.49 and R  = 0.68, p  infra-red motion-analysis (ICC = 0.81) and plumbline testing (ICC = 0.83). Reliability ranged from moderate (ICC = 0.67) for spinal mouse to very high for surface topography (Cronbach α = 0.985). Measures of agreement ranged from 0.9 mm (plumbline) to 22.94 mm (infra-red motion-analysis). Variability in study populations, reporting parameters and statistics prevented a meta-analysis. The reliability and validity of the non-radiographic methods of measuring global sagittal balance was reported within 14 identified articles. Based on this limited evidence, non-radiographic methods appear to have moderate to very high reliability and limited to three methodologies, moderate to high validity. The overall quality and methodological approaches of the included articles were highly variable. Further research should focus on the

  20. Sagittal evaluation of usual standing and sitting spinal posture.

    Science.gov (United States)

    Claeys, Kurt; Brumagne, Simon; Deklerck, Jan; Vanderhaeghen, Jacques; Dankaerts, Wim

    2016-04-01

    Postural rehabilitation often plays an important role in the management of non-specific low back pain. While cervical and lumbar correlations have been demonstrated previously, the different role of the pelvis and the thoracic spine for postural control in sitting and standing remains unclear. The aim of this study was to investigate postural correlations between all spinal regions in standing and sitting. Based on digital photographs eight postural angles were analyzed in 99 young healthy persons. Pearson correlations between different postural angles were calculated. In sitting pelvic tilt demonstrated mostly medium correlations with five out of seven other postural angles, compared to three in standing. In standing trunk angle showed five out of seven mostly medium correlations with other regions compared to four out of seven in usual sitting. The low and different correlations suggest a large between-subject variability in sagittal spinal posture, without the existence of any optimal sagittal posture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Sagittal x-ray beam deviation at asymmetric inclined diffractors

    Czech Academy of Sciences Publication Activity Database

    Korytár, D.; Hrdý, Jaromír; Artemiev, Nikolai; Ferrari, C.; Freund, A.

    2001-01-01

    Roč. 8, - (2001), s. 1136-1139 ISSN 0909-0495 R&D Projects: GA MŠk OK 305; GA MPO PZ-CH/22 Institutional research plan: CEZ:AV0Z1010914 Keywords : x-ray optics * Si(111) W/grooved crystals * inclined diffraction * out-of-diffraction-plane beams * sagittal focusing Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.519, year: 2001

  2. Thoracic lateral extracavitary corpectomy for anterior column reconstruction with expandable and static titanium cages: clinical outcomes and surgical considerations in a consecutive case series.

    Science.gov (United States)

    Holland, Christopher M; Bass, David I; Gary, Matthew F; Howard, Brian M; Refai, Daniel

    2015-02-01

    Many surgical interventions have emerged as effective means of restoring mechanical stability of the anterior column of the spine. The lateral extracavitary approach (LECA) allows for broad visualization and circumferential reconstruction of the spinal column. However, early reports demonstrated significant complication rates, protracted operative times, and prolonged hospitalizations. More recent reports have highlighted concerns for subsidence, particularly with expandable cages. Our work seeks to describe a single-surgeon consecutive series of patients undergoing LECA for thoracic corpectomy. Specifically, the objective was to explore the surgical considerations, clinical and radiographic outcomes, and complication profile of this approach. A retrospective study examined data from 17 consecutive patients in whom single or multi-level corpectomy was performed via a LECA by a single surgeon. Vertebral body replacement was achieved with either a static or expandable titanium cage. The Karnofsky Performance Scale (KPS) was utilized to assess patient functional status before and after surgery. Radiographic outcomes, particularly footplate-to-body ratio and subsidence, were assessed on CT imaging at 6 weeks after surgery and at follow-up of at least 6 months. The majority of patients had post-operative KPS scores consistent with functional independence (≥70, 12/17 patients, 71%). Fourteen patients had improved or maintained function by last follow-up. In both groups, all patients had a favorable footplate-to-body ratio, and rates of subsidence were similar at both time points. Notably, the overall complication rate (24%) was significantly lower than that published in the literature, and no patient suffered a pneumothorax that required placement of a thoracostomy tube. The LECA approach for anterior column reconstruction with static or expandable cages is an important surgical consideration with favorable surgical parameters and complication rates. Further, use of

  3. Restoration of the spinopelvic sagittal balance in isthmic spondylolisthesis: posterior lumbar interbody fusion may be better than posterolateral fusion.

    Science.gov (United States)

    Feng, Yu; Chen, Liang; Gu, Yong; Zhang, Zhi-Ming; Yang, Hui-Lin; Tang, Tian-Si

    2015-07-01

    deformity parameters. The decrease of PT may be an important role for the short-term surgical outcome. The PLIF could increase the LL and form a more reasonable sagittal alignment. From the point of the sagittal spinopelvic balance, the PLIF may be better than the PLF for patients with isthmic spondylolisthesis. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Sagittal Balance in Adolescent Idiopathic Scoliosis: A Radiographic Study of Spinopelvic Compensation After Selective Posterior Fusion of Thoracolumbar/Lumbar (Lenke 5C) Curves.

    Science.gov (United States)

    Xu, Xi-Ming; Wang, Fei; Zhou, Xiao-Yi; Liu, Zi-Xuan; Wei, Xian-Zhao; Bai, Yu-Shu; Li, Ming

    2015-11-01

    The relationship between spinal sagittal alignment and pelvic parameters is well known in adolescent idiopathic scoliosis. However, few studies have reported the sagittal spinopelvic relationship after selective posterior fusion of thoracolumbar/lumbar (TL/L) curves. We evaluated the relationship between spinal sagittal alignment and the pelvis, and analyzed how the pelvic sagittal state is adjusted in Lenke type 5C patients. We conducted a retrospective study of 36 patients with Lenke type 5C curves who received selective posterior TL/L curve fusion. Coronal and spinopelvic sagittal parameters were pre and postoperatively compared. Pearson coefficients were used to analyze the correlation between all spinopelvic sagittal parameters before and after surgery. We also evaluated 3 pelvic morphologies (anteverted, normal, and retroverted) before and after surgery. Preoperatively, the mean pelvic incidence was 46.0°, with a pelvic tilt and sacral slope (SS) of 8.2° and 37.8°, respectively, and 25% (9/36) of patients had an anteverted pelvis, whereas the other 75% had a normal pelvis. Postoperatively, 42% (15/36) of patients had a retroverted pelvis, 53% (19/36) had a normal pelvis, and 2 patients had an anteverted pelvis. Logistic regression analyses yielded 2 factors that were significantly associated with the risk for a postoperative unrecovered anteverted pelvis, including increased lumbar lordosis (LL) (odds ratio [OR] 4.8, P = 0.029) and increased SS (OR 5.6, P = 0.018). Four factors were significantly associated with the risk of a postoperative newly anteverted pelvis, including LL at the final follow-up (OR 6.9, P = 0.009), increased LL (OR 8.9, P = 0.003), LL below fusion (OR 9.4, P = 0.002), and increased SS (OR 11.5, P = 0.001). The pelvic state may be adjusted after selective posterior TL/L curve fusion in Lenke 5C adolescent idiopathic scoliosis patients. It is difficult to improve an anteverted pelvis in patients who have an LL

  5. Sagittal spinal balance after lumbar spinal fusion: the impact of anterior column support results from a randomized clinical trial with an eight- to thirteen-year radiographic follow-up.

    Science.gov (United States)

    Videbaek, Tina S; Bünger, Cody E; Henriksen, Mads; Neils, Egund; Christensen, Finn B

    2011-02-01

    Randomized clinical trial. To analyze the long-term clinical impact of anterior column support on sagittal balance after lumbar spinal fusion. Several investigators have stressed the importance of maintaining sagittal balance in relation to spinal fusion to avoid lumbar 'flat back,' accelerated adjacent segment degeneration, pain, and inferior functional outcome. Only limited evidence exists on how sagittal alignment affects clinical outcome. Anterior lumbar interbody fusion combined with posterolateral fusion has been proved superior to posterolateral fusion alone regarding outcome and cost-effectiveness. No randomized controlled trial has been published analyzing the effect of anterior support on radiographic measurements of sagittal balance. Between 1996 and 1999, 148 patients with severe chronic low back pain were randomly selected for posterolateral lumbar fusion plus anterior support (PLF + ALIF) or posterolateral lumbar fusion. A total of 92 patients participated. Sagittal balance parameters were examined on full lateral radiographs of the spine: pelvic incidence (PI), pelvic tilt (PT), sacral slope, thoracic kyphosis, lumbar lordosis, and positioning of C7 plumb line. The type of lumbar lordosis was evaluated and outcome assessed by Oswestry Disability Index (ODI). Follow-up rate was 74%. Sagittal balance parameters were similar between randomization groups. None of the parameters differed significantly between patients with an ODI from 0 to 40 and patients with ODI over 40. Balanced patients had a significantly superior outcome as measured by ODI (P Lumbar lordosis and type of lordosis correlated with outcome but could not explain the superior outcome in the group with anterior support. Whether sagittal balance and anterior support during fusion provide a protective effect on adjacent motion segments remains unclear.

  6. A reflection on radiographic cephalometry: the evaluation of sagittal discrepancy.

    Science.gov (United States)

    Duterloo, Herman S

    2014-09-01

    A critical review is presented of the basic properties and applications of cephalometry as a clinical tool with a focus on the evaluation of sagittal discrepancy. Diagnostic cephalometric assessments are subjective and not based on evidence. To assess individual skeletal and/or facial soft tissue form subjectively, selected norms are used. Norms have been developed for various ethnical groups to improve clinical applicability, but subjectivity remains. That subjectivity precludes application of a modern review system, making the present review a personal account. The cephalometric evaluation of sagittal discrepancy finds its historic origin in the Angle classification. Recent publications try to improve accuracy in classifying sagittal discrepancy. It remains unclear in what sense such efforts influence treatment decisions and/or treatment effect. Almost all selected landmarks are located on or dependent upon periosteal/endosteal bone image contours. Their homology is based on circumstantial reasoning and stability over time, which is implicitly assumed. However, implant growth studies and histological investigations show most landmarks to be unstable, as they are involved in displacement and bone remodelling. These landmarks are therefore heterologous when used for individual evaluation of change over time. Notwithstanding the above-indicated limitations, diagnostic cephalometric assessments are clinically useful and help to develop perceptions of balance and harmony and communication between colleagues and patients. There is no evidence-based method to prefer one particular diagnostic method. Landmark location accuracy and geometric issues do not play a decisive role. The subjective characteristic of diagnostic evaluations limits their power to size/shape comparisons. Structural superimposition is the valid biologically evidence-based method to provide advanced insight in individual growth and/or treatment changes and their variations. © 2014 British Orthodontic

  7. Risk factors affecting somatosensory function after sagittal split osteotomy

    DEFF Research Database (Denmark)

    Thygesen, Torben Henrik; Jensen, Allan Bardow; Helleberg, M

    2008-01-01

    Purpose The aim of this study was to evaluate potential individual and intraoperative risk factors associated with bilateral sagittal split osteotomy (BSSO) and to correlate the findings with postoperative changes in somatosensory function. Patients and Methods A total of 18 men and 29 women (mean...... correlations were noted between preoperative values for somatosensory function and changes in these variables after BSSO. Patients with low sensory thresholds before BSSO experienced more impairment than those patients with higher preoperative sensory thresholds. Conclusion These findings imply...... that somatosensory function after BSSO is dependent on both intraoperative risk factors and preoperative sensation levels....

  8. ANALYSIS AND PLANNING OF HINDFOOT DEFORMITY CORRECTION IN SAGITTAL PLANE

    Directory of Open Access Journals (Sweden)

    L. N. Solomin

    2017-01-01

    Full Text Available Background. The disadvantage of the known methods of analysis and planning of hindfoot deformities in the sagittal plaBackground. Long bone deformity planning is well established. However, there are not well described methods of analysis and planning of hindfoot deformities in the sagittal plane. Such planning is made even more difficult with concomitant deformation of the midfoot and/or ankle contracture or malpositioned arthrodesis. The aim of our study was to develop a universal method of analysis and planning of the calcaneus correction, based on the normally derived reference lines and angles.Methods. We analyzed 65 standing lateral foot films in normal adults, 23-54 years old were analyzed. We drew the talus joint line (points “a” and “b” – Line 1. We drew a second line, (Line 2 the calcaneal line, which starts at the back of the calcaneal tuberosity (point “d”, drawn perpendicular to a line from top to bottom of the calcaneal tuberosity. The intersection of the calcaneal line and the talar joint line form point (c anteriorly. We measured lines ab, ac and cd, and their ratios: ac/ab, and cd/ab.Results. Talar joint line (Line 1 and calcaneal line (Line 2 intersect at a point (c, forming an angle 15.2° (±3.4°. The ratio ac/ab = 2.56 (± 1.1. The ratio cd/ab = 4.59 (±1.0. These ratios are constants for calculating the idealized joint lines for deformity planning. For deformity cases, draw Line 1, the talar joint line ab. Extend that line anteriorly to (c, which is a distance ab×2.56 from point (a. From (c, draw an idealized calcaneal line, Line-2, at an angle 15° to Line 1. Place (d on this line, at a distance ab×4.59 from point (c. Next, draw the deformed calcaneal line (Line 3 and point (d1 where it exits the calcaneal tuberosity. Use the same technique and landmarks as for drawing the normal calcaneal line. The intersection of Lines 2 and 3 is the apex of the deformity. Rotate the piece containing Line 3 around this

  9. Articulator-related registration and analysis of sagittal condylar inclination

    OpenAIRE

    Čimić, Samir; Kraljević Šimunković, Sonja; Simonić Kocijan, Sunčana; Matijević, Jurica; Dulčić, Nikša; Ćatić, Amir

    2015-01-01

    The purpose of this investigation was to study sagittal condylar inclination values within a uniform sample (Angle class I occlusion) using ‘articulator-related registration’ and Camper’s plane as a reference plane. The study was performed on a sample of 58 Angle class I subjects (mean age 25.1, SD 3.1). Measurements were performed with an ultrasonic jaw tracking device with six degrees of freedom. After a paraocclusal tray was fixed in the mouth, each subject had to make three protrusive ...

  10. Diagnosis and evaluation of esophageal atresia by direct sagittal CT

    International Nuclear Information System (INIS)

    Tam, P.K.H.; Saing, H.; Chan, F.L.

    1987-01-01

    Direct sagittal CT is possible in newborns because of their small body-size. With this noninvasive investigation, we were able to establish a correct diagnosis in two neonates with esophageal atresia. Moreover, the demonstration of the air-filled proximal pouch and distal tracheoesophageal fistula along their whole lengths allowed exclusion of the possibility of a proximal pouch fistula and gave knowledge of the exact distance of the two segments of the esophagus needed to be bridged to allow anastomosis, thus providing additional valuable information for the surgeon preoperatively.

  11. A Comparative Study of Sagittal Balance in Patients with Neuromuscular Scoliosis

    Directory of Open Access Journals (Sweden)

    Paulo Alvim Borges

    Full Text Available OBJECTIVES: Spinopelvic alignment has been associated with improved quality of life in patients with vertebral deformities, and it helps to compensate for imbalances in gait. Although surgical treatment of scoliosis in patients with neuromuscular spinal deformities promotes correction of coronal scoliotic deformities, it remains poorly established whether this results in large changes in sagittal balance parameters in this specific population. The objective of this study is to compare these parameters before and after the current procedure under the hypothesis is that there is no significant modification. METHODS: Sampling included all records of patients with neuromuscular scoliosis with adequate radiographic records treated at Institute of Orthopedics and Traumatology of Clinics Hospital of University of São Paulo (IOT-HCFMUSP from January 2009 to December 2013. Parameters analyzed were incidence, sacral inclination, pelvic tilt, lumbar lordosis, thoracic kyphosis, spinosacral angle, spinal inclination and spinopelvic inclination obtained using the iSite-Philips digital display system with Surgimap and a validated method for digital measurements of scoliosis radiographs. Comparison between the pre- and post-operative conditions involved means and standard deviations and the t-test. RESULTS: Based on 101 medical records only, 16 patients met the inclusion criteria for this study, including 7 males and 9 females, with an age range of 9-20 and a mean age of 12.9±3.06; 14 were diagnosed with cerebral palsy. No significant differences were found between pre and postoperative parameters. CONCLUSIONS: Despite correction of coronal scoliotic deformity in patients with neuromuscular deformities, there were no changes in spinopelvic alignment parameters in the group studied.

  12. Evaluation of palatal rugae pattern in different sagittal skeletal relationship adolescent subjects.

    Science.gov (United States)

    Oral, Ekrem; Buyuk, S Kutalmiş; Simsek, Huseyin

    2017-04-01

    The purpose of this study was to evaluate the morphological structure of palatal rugae in Turkish orthodontic subjects with different sagittal skeletal malocclusions. Orthodontic dental casts of 105 patients (Class I [23 females, 12 males]; 35, Class II [18 females, 17 males]; and 35, Class III [14 females, 21 males] 10-22 years old) were analyzed for rugae patterns. Palatal rugae pattern and number, direction of rugae alignment, shape of incisive papilla were analyzed. Modified Thomas and Kotze classification was performed to analyze palatal rugae characteristics. The data were analyzed using the Kruskal-Wallis test. Wavy and curved types were the most common types of rugae pattern in all groups (Class I, Class II, Class III). As regards to the number of primary and secondary rugae on the left and right sides, there was no statistically significant difference among subjects with different skeletal malocclusions. Droplet-shaped incisive papilla was the most common form of incisive papillae among different skeletal malocclusion groups. The most common palatal rugae were direction type arranged in the horizontal direction. All rugae patterns were unique for each individual. The use of antemortem or postmortem palatal rugae records may facilitate identification of the suspects in forensic investigations by enabling facial reconstruction through skeletal malocclusions.

  13. Does Andrews facial analysis predict esthetic sagittal maxillary position?

    Science.gov (United States)

    Resnick, Cory M; Daniels, Kimberly M; Vlahos, Maryann

    2018-04-01

    Cephalometric analyses have limited utility in planning maxillary sagittal position for orthognathic surgery. In Six Elements of Orofacial Harmony, Andrews quantified maxillary position relative to forehead projection and angulation and proposed an ideal relationship. The purpose of this study was to investigate the ability of this technique to predict esthetic sagittal maxillary position. Survey study including a male and female with straight facial profiles, normal maxillary incisor angulations, and Angle's Class I. Maxillary position was modified on lateral photographs to create 5 images for each participant with incisor-goal anterior limit line (GALL) distances of -4, -2, 0, +2, and +4 mm. A series of health care professionals and laypeople were asked to rate each photo in order of attractiveness. A total of 100 complete responses were received. Incisor-GALL distances of +4 mm (41%) and +2 mm (40%) were most commonly considered "most esthetic" for the female volunteer (P < .001). For the male volunteer, there were 2 peak "most esthetic" responses: incisor-GALL distances of 0 mm (37%) and -4 mm (32%) (P < .001). Respondents considered maxillary incisor position 2 to 4 mm anterior to GALL most attractive in a woman and 0 to 4 mm posterior to GALL most esthetic in a man. Using these modified target distances, this analysis may be useful for orthognathic surgery planning. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Vertebral artery loop formation depicted on oblique sagittal MR imaging: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Sun Woo; Han, Kyung Ream; Lee, Mi Kyung; Kim, Hyung Nam; Han, Jae Il; Park, Mi Na; Kim, Chan [Kim Chan Hospital, Suwon (Korea, Republic of)

    2015-02-15

    Vertebral artery loop formation is an anatomic variation that possibly causes cervical nerve root compression, leading to cervical radiculopathy. A few cases of vertebral artery loop formation depicted with conventional sagittal magnetic resonance imaging (MRI) have been reported, but cases of vertebral artery loop formation depicted with oblique sagittal MRI have been less frequently reported. We present a case of vertebral artery loop formation depicted on oblique sagittal MRI.

  15. Vertebral artery loop formation depicted on oblique sagittal MR imaging: A case report

    International Nuclear Information System (INIS)

    Bang, Sun Woo; Han, Kyung Ream; Lee, Mi Kyung; Kim, Hyung Nam; Han, Jae Il; Park, Mi Na; Kim, Chan

    2015-01-01

    Vertebral artery loop formation is an anatomic variation that possibly causes cervical nerve root compression, leading to cervical radiculopathy. A few cases of vertebral artery loop formation depicted with conventional sagittal magnetic resonance imaging (MRI) have been reported, but cases of vertebral artery loop formation depicted with oblique sagittal MRI have been less frequently reported. We present a case of vertebral artery loop formation depicted on oblique sagittal MRI.

  16. Intramedullary versus extramedullary alignment of the tibial component in the Triathlon knee

    LENUS (Irish Health Repository)

    Cashman, James P

    2011-08-20

    Abstract Background Long term survivorship in total knee arthroplasty is significantly dependant on prosthesis alignment. Our aim was determine which alignment guide was more accurate in positioning of the tibial component in total knee arthroplasty. We also aimed to assess whether there was any difference in short term patient outcome. Method A comparison of intramedullary versus extramedullary alignment jig was performed. Radiological alignment of tibial components and patient outcomes of 103 Triathlon total knee arthroplasties were analysed. Results Use of the intramedullary was found to be significantly more accurate in determining coronal alignment (p = 0.02) while use of the extramedullary jig was found to give more accurate results in sagittal alignment (p = 0.04). There was no significant difference in WOMAC or SF-36 at six months. Conclusion Use of an intramedullary jig is preferable for positioning of the tibial component using this knee system.

  17. Intramedullary versus extramedullary alignment of the tibial component in the Triathlon knee

    Directory of Open Access Journals (Sweden)

    Synnott Keith

    2011-08-01

    Full Text Available Abstract Background Long term survivorship in total knee arthroplasty is significantly dependant on prosthesis alignment. Our aim was determine which alignment guide was more accurate in positioning of the tibial component in total knee arthroplasty. We also aimed to assess whether there was any difference in short term patient outcome. Method A comparison of intramedullary versus extramedullary alignment jig was performed. Radiological alignment of tibial components and patient outcomes of 103 Triathlon total knee arthroplasties were analysed. Results Use of the intramedullary was found to be significantly more accurate in determining coronal alignment (p = 0.02 while use of the extramedullary jig was found to give more accurate results in sagittal alignment (p = 0.04. There was no significant difference in WOMAC or SF-36 at six months. Conclusion Use of an intramedullary jig is preferable for positioning of the tibial component using this knee system.

  18. Effect of mat pilates exercise on postural alignment and body composition of middle-aged women.

    Science.gov (United States)

    Lee, Hyo Taek; Oh, Hyun Ok; Han, Hui Seung; Jin, Kwang Youn; Roh, Hyo Lyun

    2016-06-01

    [Purpose] This study attempted to examine whether Pilates is an effective exercise for improving the postural alignment and health of middle-aged women. [Subjects and Methods] The participants in this study were 36 middle-aged women (20 in the experimental group, 16 in the control group). The experimental group participated in Pilates exercise sessions three times a week for 12 weeks. Body alignment and composition measurements before and after applying the Pilates exercise program were performed with a body composition analyzer and a three-dimensional scanner. [Results] Postural alignment in the sagittal and horizontal planes was enhanced in the Pilates exercise group. Trunk alignment showed correlations with body fat and muscle mass. [Conclusion] The Pilates exercises are performed symmetrically and strengthen the deep muscles. Moreover, the results showed that muscle mass was correlated with trunk postural alignment and that the proper amount of muscle is critical in maintaining trunk postural alignment.

  19. What is the optimal alignment of the tibial and femoral components in knee arthroplasty?

    DEFF Research Database (Denmark)

    Gromov, Kirill; Korchi, Mounim; Thomsen, Morten G

    2014-01-01

    Background - Surgeon-dependent factors such as optimal implant alignment are thought to play a significant role in outcome following primary total knee arthroplasty (TKA). Exact definitions and references for optimal alignment are, however, still being debated. This overview of the literature...... components and their role in outcome and implant survival. Methods - We performed a literature search for original and review articles on implant positioning following primary TKA. Definitions for coronal, sagittal, and rotational placement of femoral and tibial components were summarized and the influence...... rates, maltracking, and knee pain. Interpretation - Based on currently available evidence, surgeons should aim for optimal alignment of tibial and femoral components when performing TKA....

  20. A Computer Navigation System Analysis of the Accuracy of the Extramedullary (Tibial Alignment Technique in Total Knee Arthroplasty (TKA

    Directory of Open Access Journals (Sweden)

    EK Chee

    2010-07-01

    Full Text Available In total knee arthroplasty, mechanical alignment guides have improved the accuracy of implant alignment, but errors are not uncommon. In the present study, an image-free computer-assisted navigation system was used to analyse the accuracy of an extramedullary (tibial alignment system, which is based on predetermined, fixed anatomical landmarks. Comparisons were made between two surgeons, with different levels of competency in order to determine if experience affected the accuracy of extramedullary tibial jig placement, in either the coronal and sagittal planes or both planes. The results showed that the accuracy of the extramedullary tibial alignment system, in the coronal plane (in up to 80-87% of cases was much better than for posterior slope, and sagittal plane. Surgeon experience was not a significant factor.

  1. Reliability and Validity Measurement of Sagittal Lumbosacral Quiet Standing Posture with a Smartphone Application in a Mixed Population of 183 College Students and Personnel

    Directory of Open Access Journals (Sweden)

    George A. Koumantakis

    2016-01-01

    Full Text Available Accurate recording of spinal posture with simple and accessible measurement devices in clinical practice may lead to spinal loading optimization in occupations related to prolonged sitting and standing postures. Therefore, the purpose of this study was to establish the level of reliability of sagittal lumbosacral posture in quiet standing and the validity of the method in differentiating between male and female subjects, establishing in parallel a normative database. 183 participants (83 males and 100 females, with no current low back or pelvic pain, were assessed using the “iHandy Level” smartphone application. Intrarater reliability (3 same-day sequential measurements was high for both the lumbar curve (ICC2,1: 0.96, SEM: 2.13°, and MDC95%: 5.9° and the sacral slope (ICC2,1: 0.97, SEM: 1.61°, and MDC95%: 4.46° sagittal alignment. Data analysis for each gender separately confirmed equally high reliability for both male and female participants. Correlation between lumbar curve and sacral slope was high (Pearson’s r=0.86, p<0.001. Between-gender comparisons confirmed the validity of the method to differentiate between male and female lumbar curve and sacral slope angles, with females generally demonstrating greater lumbosacral values (p<0.001. The “iHandy Level” application is a reliable and valid tool in the measurement of lumbosacral quiet standing spinal posture in the sagittal plane.

  2. Reliability and Validity Measurement of Sagittal Lumbosacral Quiet Standing Posture with a Smartphone Application in a Mixed Population of 183 College Students and Personnel.

    Science.gov (United States)

    Koumantakis, George A; Nikoloudaki, Maria; Thacheth, Sara; Zagli, Kalliroi; Bitrou, Konstantina; Nigritinos, Andreas; Botton, Leon

    2016-01-01

    Accurate recording of spinal posture with simple and accessible measurement devices in clinical practice may lead to spinal loading optimization in occupations related to prolonged sitting and standing postures. Therefore, the purpose of this study was to establish the level of reliability of sagittal lumbosacral posture in quiet standing and the validity of the method in differentiating between male and female subjects, establishing in parallel a normative database. 183 participants (83 males and 100 females), with no current low back or pelvic pain, were assessed using the "iHandy Level" smartphone application. Intrarater reliability (3 same-day sequential measurements) was high for both the lumbar curve (ICC 2,1 : 0.96, SEM: 2.13°, and MDC 95% : 5.9°) and the sacral slope (ICC 2,1 : 0.97, SEM: 1.61°, and MDC 95% : 4.46°) sagittal alignment. Data analysis for each gender separately confirmed equally high reliability for both male and female participants. Correlation between lumbar curve and sacral slope was high (Pearson's r = 0.86, p < 0.001). Between-gender comparisons confirmed the validity of the method to differentiate between male and female lumbar curve and sacral slope angles, with females generally demonstrating greater lumbosacral values ( p < 0.001). The "iHandy Level" application is a reliable and valid tool in the measurement of lumbosacral quiet standing spinal posture in the sagittal plane.

  3. Recurrent anterior cervical wound abscesses following cervical corpectomy and fusion surgery from an odontogenic source mimicking an esophageal perforation: a case report.

    Science.gov (United States)

    Pan, Tiffany J; Neral, Mithun; Gordon, Zachary; Kang, James D

    2016-06-01

    Infection is an uncommon complication of anterior cervical spine surgery. Most deep postoperative infections are thought to be related to occult esophageal perforation. Direct inoculation from the oropharynx has not been previously reported in the literature. The purpose of this study is to report a case of recurrent infection after anterior cervical decompression and fusion suspected to have resulted from direct communication between the oropharynx and deep neck space. This study is a case report. This study included longitudinal clinical and radiological follow-up. A 48-year-old woman who underwent anterior cervical corpectomy and fusion from C3 to C6 and posterior spinal fusion from C3 to C7 presented at 2 weeks and 5 months postoperatively with a deep neck space infection. She underwent surgical debridement each time. Workup of the second infection found a subtle cortical breach in the mandible at the site of prior invasive dental work. This case describes the workup and management of a patient who presented with recurrent deep neck space infection following anterior cervical spine surgery. This is the first report of a postoperative infection related to direct communication between the oropharynx and deep neck space via a cortical breach of the mandible. Copyright © 2016. Published by Elsevier Inc.

  4. Sagittal spinopelvic parameters in 2-level lumbar degenerative spondylolisthesis

    Science.gov (United States)

    Wang, Tao; Wang, Hui; Liu, Huan; Ma, Lei; Liu, Feng-Yu; Ding, Wen-Yuan

    2016-01-01

    Abstract The purpose of our study is to evaluate sagittal parameters in 2-level lumbar degenerative spondylolisthesis (DS) (TLDS). A total of 15 patients with TLDS, 40 patients with single-level DS (SLDS), and 30 normal volunteers as control were included in our study. All subjects performed on full spine X-ray. Two categorized data were analyzed: patient characteristics—age, sex, body mass index, radiographic parameters-pelvic incidence (PI), pelvic tilt (PT), lumbar lordosis (LL), sacral slope (SS), PI–LL, Cobb between the fifth thoracic vertebral and 12th thoracic vertebral (T5–T12), sagittal vertical axis (SVA) Cobb angle of spondylolisthesis level (CSL), ratio of PT to SS (PT/SS), CSL/LL, variation trend of SS over PI, and LL over PI. The PI (73.1° vs 52.9°), SS (50.8° vs 32.2°), LL (53.1° vs 46.9°), SVA (66.1 vs 22.0 mm), PI–LL (20.0° vs 6.0°), and CSL (23.6° vs 20.0°) in TLDS were significantly larger than these in SLDS. The PI (73.1° vs 40.6°), PT (22.3° vs 17.1°), SS (50.8° vs 23.5°), LL (53.1° vs 32.5°), PI–LL (20.0° vs 8.1°), and SVA (66.1 vs 17.0 mm) in TLDS were significantly larger than those in the normal group (NG). The PI (52.9° vs 40.6°), PT (21.0° vs 17.1°), SS (32.2° vs 23.5°), LL (46.9° vs 32.5°), and SVA (22.0 vs 17.0 mm) in SLDS were significantly higher than those in NG. However, PT/SS (44.0%), LL over PI (y = 0.39x + 24.25), SS over PI (y = 10.79 + 0.55x) were lower in TLDS than these in SLDS (63.8%, y = 0.41x + 25, y = 0.65x − 2.09, respectively), and the similar tend between SLDS and NG (74.0%, y = 0.49x + 13.09, y = 0.67x − 3.9, respectively). Our results showed that 2-level lumbar DS, which was caused by multiple-factors, has a severe sagittal imbalance, but single-level has not any. When we plan for surgical selection for 2-level lumbar DS, global sagittal balance must be considered. PMID:27977581

  5. Assessment of spring cranioplasty biomechanics in sagittal craniosynostosis patients.

    Science.gov (United States)

    Borghi, Alessandro; Schievano, Silvia; Rodriguez Florez, Naiara; McNicholas, Roisin; Rodgers, Will; Ponniah, Allan; James, Greg; Hayward, Richard; Dunaway, David; Jeelani, N U Owase

    2017-11-01

    OBJECTIVE Scaphocephaly secondary to sagittal craniosynostosis has been treated in recent years with spring-assisted cranioplasty, an innovative approach that leverages the use of metallic spring distractors to reshape the patient skull. In this study, a population of patients who had undergone spring cranioplasty for the correction of scaphocephaly at the Great Ormond Street Hospital for Children was retrospectively analyzed to systematically assess spring biomechanical performance and kinematics in relation to spring model, patient age, and outcomes over time. METHODS Data from 60 patients (49 males, mean age at surgery 5.2 ± 0.9 months) who had received 2 springs for the treatment of isolated sagittal craniosynostosis were analyzed. The opening distance of the springs at the time of insertion and removal was retrieved from the surgical notes and, during the implantation period, from planar radiographs obtained at 1 day postoperatively and at the 3-week follow-up. The force exerted by the spring to the patient skull at each time point was derived after mechanical testing of each spring model-3 devices with the same geometry but different wire thicknesses. Changes in the cephalic index between preoperatively and the 3-week follow-up were recorded. RESULTS Stiffer springs were implanted in older patients (p springs were used (p spring models, however, the devices all plateaued. Indeed, regardless of patient age or spring model, after 10 days from insertion, all the devices were open. CONCLUSIONS Results in this study provide biomechanical insights into spring-assisted cranioplasty and could help to improve spring design and follow-up strategy in the future.

  6. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    G.Gomez.

    Since June of 2009, the muon alignment group has focused on providing new alignment constants and on finalizing the hardware alignment reconstruction. Alignment constants for DTs and CSCs were provided for CRAFT09 data reprocessing. For DT chambers, the track-based alignment was repeated using CRAFT09 cosmic ray muons and validated using segment extrapolation and split cosmic tools. One difference with respect to the previous alignment is that only five degrees of freedom were aligned, leaving the rotation around the local x-axis to be better determined by the hardware system. Similarly, DT chambers poorly aligned by tracks (due to limited statistics) were aligned by a combination of photogrammetry and hardware-based alignment. For the CSC chambers, the hardware system provided alignment in global z and rotations about local x. Entire muon endcap rings were further corrected in the transverse plane (global x and y) by the track-based alignment. Single chamber track-based alignment suffers from poor statistic...

  7. Strategic Considerations for Effective Sagittal Resection of the Mandible to Achieve a Slim and Attractive Jawline.

    Science.gov (United States)

    Park, Sanghoon; Lee, Tae Sung

    2018-01-01

    Sagittal resection of the mandible has been widely used to reduce the width of the lower face and is usually carried out in combination with a mandibular contouring procedure. However, the surgical outcomes of this procedure are unclear because sagittal resection is rarely performed as a single procedure. The authors clarify misunderstandings regarding this procedure and introduce an improved strategic approach for sagittal resection of the mandible. Under general anesthesia, mandible contouring was performed first with a curved osteotomy, followed by sagittal resection of the outer cortex of mandible. The amount and extent of each procedure was determined in accordance with preoperative analysis. From 2012 to 2014, a consecutive series of 212 patients who underwent mandible contouring surgery without concomitant chin surgery were included in the study. A total of 189 patients underwent both mandibular contouring surgery and sagittal resection, whereas 13 underwent only sagittal resection and 10 underwent only mandibular contouring surgery. All operations were carried out successfully without any severe complications, and most patients had satisfactory aesthetic outcomes. The authors found that the sagittal resection of the mandible should be performed in accordance with the shape of the mandible to effectively reduce facial width and achieve better aesthetic outcomes for both profile and frontal views. In an outcurved-type mandible, conventional mandibular contouring may be effective alone, whereas sagittal resection focusing on removing the mandible body region is essential for incurved-type mandibles. In straight line-type mandibles, both procedures are necessary. Therapeutic, IV.

  8. Extensor Tendon Instability Due to Sagittal Band Injury in a Martial Arts Athlete: A Case Report.

    Science.gov (United States)

    Kochevar, Andrew; Rayan, Ghazi

    2017-03-01

    A Taekwondo participant sustained a hand injury from punching an opponent that resulted in painful instability of the ring finger extensor digitorum communis tendon due to sagittal band damage. His symptoms resolved after reconstructive surgery on the sagittal band (SB) with stabilization of the extensor tendon over the metacarpophalangeal joint.

  9. Sagittal synostosis: II. Cranial morphology and growth after the modified pi-plasty

    DEFF Research Database (Denmark)

    Guimaraes-Ferreira, J.; Gewalli, F.; David, L.

    2006-01-01

    The aim of this study was to characterise the postoperative cranial growth and morphology after a modified pi-plasty for sagittal synostosis. The shape of the skull of 82 patients with isolated premature synostosis of the sagittal suture ( SS group) operated on with a modified pi-plasty was studi...

  10. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    G. Gomez and J. Pivarski

    2011-01-01

    Alignment efforts in the first few months of 2011 have shifted away from providing alignment constants (now a well established procedure) and focussed on some critical remaining issues. The single most important task left was to understand the systematic differences observed between the track-based (TB) and hardware-based (HW) barrel alignments: a systematic difference in r-φ and in z, which grew as a function of z, and which amounted to ~4-5 mm differences going from one end of the barrel to the other. This difference is now understood to be caused by the tracker alignment. The systematic differences disappear when the track-based barrel alignment is performed using the new “twist-free” tracker alignment. This removes the largest remaining source of systematic uncertainty. Since the barrel alignment is based on hardware, it does not suffer from the tracker twist. However, untwisting the tracker causes endcap disks (which are aligned ...

  11. [Cephalometric analysis of the relationship between occlusal plane and sagittal position of the mandible].

    Science.gov (United States)

    Ye, Rui; Wang, Sheng; Pei, Jiao; Zhao, Meiying

    2012-12-01

    To investigate the relationship between occlusal plane and sagittal position of the mandible by examining dental and skeletal morphologies of average angle patients for better understanding of etiologies and definitive clinical guidelines of mandibular malpositions. The lateral cephalograms of 114 female average angle patients with neutral maxillary positions were selected and divided into three groups according to sagittal mandibular positions (ANB angle). Twenty-five skeletal and dental measurements were compared. The correlations between skeletal and dental measurements were analyzed by rectilinear correlation. Cant of posterior occlusal plane (OP-P) and height of the upper second molar were significantly related to sagittal position of the mandible (P occlusal plane and sagittal position of the mandible in average angle patients, consistent with the dental morphologies of different skeletal configurations. In treating malocclusions of sagittal discrepancy of mandible, the height of posterior teeth and cant of OP-P might be a primary concern.

  12. Anterior corpectomy via the mini-open, extreme lateral, transpsoas approach combined with short-segment posterior fixation for single-level traumatic lumbar burst fractures: analysis of health-related quality of life outcomes and patient satisfaction.

    Science.gov (United States)

    Theologis, Alexander A; Tabaraee, Ehsan; Toogood, Paul; Kennedy, Abbey; Birk, Harjus; McClellan, R Trigg; Pekmezci, Murat

    2016-01-01

    The authors present clinical outcome data and satisfaction of patients who underwent minimally invasive vertebral body corpectomy and cage placement via a mini-open, extreme lateral, transpsoas approach and posterior short-segment instrumentation for lumbar burst fractures. Patients with unstable lumbar burst fractures who underwent corpectomy and anterior column reconstruction via a mini-open, extreme lateral, transpsoas approach with short-segment posterior fixation were reviewed retrospectively. Demographic information, operative parameters, perioperative radiographic measurements, and complications were analyzed. Patient-reported outcome instruments (Oswestry Disability Index [ODI], 12-Item Short Form Health Survey [SF-12]) and an anterior scar-specific patient satisfaction questionnaire were recorded at the latest follow-up. Twelve patients (7 men, 5 women, average age 42 years, range 22-68 years) met the inclusion criteria. Lumbar corpectomies with anterior column support were performed (L-1, n = 8; L-2, n = 2; L-3, n = 2) and supplemented with short-segment posterior instrumentation (4 open, 8 percutaneous). Four patients had preoperative neurological deficits, all of which improved after surgery. No new neurological complications were noted. The anterior incision on average was 6.4 cm (range 5-8 cm) in length, caused mild pain and disability, and was aesthetically acceptable to the large majority of patients. Three patients required chest tube placement for pleural violation, and 1 patient required reoperation for cage subsidence/hardware failure. Average clinical follow-up was 38 months (range 16-68 months), and average radiographic follow-up was 37 months (range 6-68 months). Preoperative lumbar lordosis and focal lordosis were significantly improved/maintained after surgery. Patients were satisfied with their outcomes, had minimal/moderate disability (average ODI score 20, range 0-52), and had good physical (SF-12 physical component score 41.7% ± 10

  13. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    G.Gomez

    2010-01-01

    The main developments in muon alignment since March 2010 have been the production, approval and deployment of alignment constants for the ICHEP data reprocessing. In the barrel, a new geometry, combining information from both hardware and track-based alignment systems, has been developed for the first time. The hardware alignment provides an initial DT geometry, which is then anchored as a rigid solid, using the link alignment system, to a reference frame common to the tracker. The “GlobalPositionRecords” for both the Tracker and Muon systems are being used for the first time, and the initial tracker-muon relative positioning, based on the link alignment, yields good results within the photogrammetry uncertainties of the Tracker and alignment ring positions. For the first time, the optical and track-based alignments show good agreement between them; the optical alignment being refined by the track-based alignment. The resulting geometry is the most complete to date, aligning all 250 DTs, ...

  14. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    Z. Szillasi and G. Gomez.

    2013-01-01

    When CMS is opened up, major components of the Link and Barrel Alignment systems will be removed. This operation, besides allowing for maintenance of the detector underneath, is needed for making interventions that will reinforce the alignment measurements and make the operation of the alignment system more reliable. For that purpose and also for their general maintenance and recalibration, the alignment components will be transferred to the Alignment Lab situated in the ISR area. For the track-based alignment, attention is focused on the determination of systematic uncertainties, which have become dominant, since now there is a large statistics of muon tracks. This will allow for an improved Monte Carlo misalignment scenario and updated alignment position errors, crucial for high-momentum muon analysis such as Z′ searches.

  15. Sagittal plane kinematics of the foot during passive ankle dorsiflexion.

    Science.gov (United States)

    Gatt, Alfred; Chockalingam, Nachiappan; Chevalier, Thierry Larose

    2011-12-01

    Measurement of ankle joint dorsiflexion is an essential examination technique that needs to be performed prior to prescription of foot orthoses since the presence or absence of ankle equinus will affect the design of such devices. The purpose of this study was to investigate the effect of foot posture on sagittal plane kinematics of various foot segments during passive dorsiflexion. Comparative repeated measures design. To determine the effect of foot posture on inter segmental kinematics during passive dorsiflexion. An optoelectronic movement analysis system was employed to collect kinematic data. A validated marker set (Oxford Foot Model) was applied to 16 subjects (12 males, 4 females) with a mean age of 35.5 years (range 20-56 years), who provided informed consent. An upward force was applied to the forefoot until maximum resistance. Sagittal movement of the hindfoot and forefoot segments along with the whole foot movement were analyzed in the pronated, neutral and supinated foot postures. While maximum foot dorsiflexion angle showed a significant difference between the three postures (p = 0.000) the actual recorded difference between the neutral and supinated postures was only 2.49°. For the hindfoot and forefoot segments, mean angle range of movement for the pronated foot posture was significantly higher than the other foot postures. The forefoot to hindfoot angle demonstrated a significant (p = 0.005) increase during dorsiflexion between the pronated and supinated postures. These results indicate that during passive dorsiflexion, the forefoot travels through a greater degree of movement than the hindfoot. While the maximum foot dorsiflexion angle differs significantly between the pronated and supinated foot postures, hindfoot movement also varies significantly between foot postures. Furthermore, the forefoot to tibia angle travels through a greater range than the hindfoot to tibia angle, in all three foot postures. The hindfoot to forefoot angle does not

  16. Back to the future: sagittal CT in the evaluation of COPD

    International Nuclear Information System (INIS)

    Hightower, Jessica S.; Amadi, Chiemezie; Den, Elana; Schmitt, James E.; Shah, Rosita M.; Miller, Wallace T.

    2016-01-01

    To identify features of obstructive airway disease on sagittal reconstruction, compare the accuracy of findings to traditional imaging characteristics of COPD, and determine the fraction of additional cases identified using new characteristics. The study was approved by the centre's Institutional Review Board and is HIPAA compliant. Two hundred sixteen patients with HRCT and spirometry within a 3-month window were included. Four radiologists evaluated each HRCT for traditional characteristics of COPD and new quantitative and qualitative features of obstruction on axial and sagittal reconstructions. Imaging characteristics were assessed for correlation with the spirometric diagnosis of obstructive airway disease. Quantitative and qualitative findings on sagittal reconstruction are highly specific for COPD (specificity >90 %). Features of hyperinflation on sagittal reconstruction are more accurate predictors of obstruction than traditional axial measures, with greater interobserver reliability (hyperinflation left hemidiaphragm: accuracy: 70.08 % ± 2.49 %; kappa: 0.511 versus traditional measures: accuracy: 62.00 % ± 5.38 %; kappa: 0.407). Sagittal reconstruction identified 27-70 % more patients with COPD than traditional axial findings (p < 0.05). Analysis of sagittal reconstruction enables greater accuracy and specificity in the diagnosis of obstructive airway disease compared to traditional measures on axial imaging. Use of sagittal reconstructions can help identify up to 70 % more patients with COPD than traditional imaging findings alone. (orig.)

  17. Importance of sagittal MR imaging in nontraumatic femoral head osteonecrosis in children

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Alice S. [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Wells, Lawrence [Children' s Hospital of Philadelphia, Department of Orthopedic Surgery, Philadelphia, PA (United States); Jaramillo, Diego [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2008-11-15

    In nontraumatic femoral head osteonecrosis, characterization of femoral head collapse is important in staging disease progression and planning treatment. Few prior studies have quantitatively compared the ability of sagittal and coronal MR images to detect femoral head collapse. We hypothesized that sagittal MR images show a greater degree and angular span of femoral head collapse than coronal images. We reviewed 38 hip MRI scans of nontraumatic femoral head osteonecrosis from 34 pediatric patients. In both sagittal and coronal images, the maximal extent and angular location along with the angular span of the femoral head collapse were measured. Differences were evaluated using a paired t-test. The extent of bone and cartilage loss from the femoral head was evaluated. Sagittal MR images showed 29% maximal femoral head radius collapse, whereas coronal images showed 16% collapse (P<0.001). Sagittal images showed a larger angular span of collapse (115 ) than coronal images (55 , P<0.001). Sagittal images showed greater epiphyseal bone loss in the anterior than in the posterior portion (P<0.001), whereas coronal images did not show a significant difference in bone loss between the medial and lateral portion (P=0.32). Sagittal images show greater femoral head collapse than coronal images in nontraumatic femoral head osteonecrosis. (orig.)

  18. Importance of sagittal MR imaging in nontraumatic femoral head osteonecrosis in children

    International Nuclear Information System (INIS)

    Ha, Alice S.; Wells, Lawrence; Jaramillo, Diego

    2008-01-01

    In nontraumatic femoral head osteonecrosis, characterization of femoral head collapse is important in staging disease progression and planning treatment. Few prior studies have quantitatively compared the ability of sagittal and coronal MR images to detect femoral head collapse. We hypothesized that sagittal MR images show a greater degree and angular span of femoral head collapse than coronal images. We reviewed 38 hip MRI scans of nontraumatic femoral head osteonecrosis from 34 pediatric patients. In both sagittal and coronal images, the maximal extent and angular location along with the angular span of the femoral head collapse were measured. Differences were evaluated using a paired t-test. The extent of bone and cartilage loss from the femoral head was evaluated. Sagittal MR images showed 29% maximal femoral head radius collapse, whereas coronal images showed 16% collapse (P<0.001). Sagittal images showed a larger angular span of collapse (115 ) than coronal images (55 , P<0.001). Sagittal images showed greater epiphyseal bone loss in the anterior than in the posterior portion (P<0.001), whereas coronal images did not show a significant difference in bone loss between the medial and lateral portion (P=0.32). Sagittal images show greater femoral head collapse than coronal images in nontraumatic femoral head osteonecrosis. (orig.)

  19. Sagittal plane momentum control during walking in elderly fallers.

    Science.gov (United States)

    Fujimoto, Masahiro; Chou, Li-Shan

    2016-03-01

    The purpose of this study was to examine sagittal plane momentum control during walking with the use of center of mass (COM) velocity and acceleration. COM control in the antero-posterior direction during walking of healthy young and elderly adults, and elderly fallers (n=15/group) was examined. Using a single-link-plus-foot inverted pendulum model, boundaries for the region of stability were determined based on the COM position at toe-off and its instantaneous velocity or the peak acceleration prior to toe-off (ROSv or ROSa, respectively). Although no significant difference in forward COM velocity was detected between healthy young and elderly subjects, the peak forward COM acceleration differed significantly, suggesting age-related differences in momentum control during walking. Elderly fallers demonstrated significantly slower forward COM velocities and accelerations and placed their COM significantly more anterior than healthy young and elderly subjects at toe-off, which resulted in their COM position-velocity combination located within the ROSv. Similar results were obtained in the ROSa, where elderly fallers demonstrated a larger stability margin than healthy young and elderly subjects. Significantly slower peak COM accelerations could be indicative of a poor momentum control ability, which was more pronounced in elderly fallers. Examining COM acceleration, in addition to its velocity, would provide a greater understanding of person's momentum control, which would allow us to better reveal underlying mechanisms of gait imbalance or falls. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Human foot placement and balance in the sagittal plane.

    Science.gov (United States)

    Millard, Matthew; Wight, Derek; McPhee, John; Kubica, Eric; Wang, David

    2009-12-01

    Foot placement has long been recognized as the primary mechanism that humans use to restore balance. Many biomechanists have examined where humans place their feet during gait, perturbations, and athletic events. Roboticists have also used foot placement as a means of control but with limited success. Recently, Wight et al. (2008, "Introduction of the Foot Placement Estimator: A Dynamic Measure of Balance for Bipedal Robotics," ASME J. Comput. Nonlinear Dyn., 3, p. 011009) introduced a planar foot placement estimator (FPE) algorithm that will restore balance to a simplified biped that is falling. This study tested the FPE as a candidate function for sagittal plane human-foot-placement (HFP) by recording the kinematics of 14 healthy subjects while they performed ten walking trials at three speeds. The FPE was highly correlated with HFP (rho>or=0.997) and its accuracy varied linearly from 2.6 cm to -8.3 cm as walking speed increased. A sensitivity analysis revealed that assumption violations of the FPE cannot account for the velocity-dependent changes in FPE-HFP error suggesting that this behavior is volitional.

  1. Assessment of Gender Dimorphism on Sagittal Cephalometry in Pakistani Population

    International Nuclear Information System (INIS)

    Qamruddin, I.; Shahid, F.; Tanveer, S.; Mukhtiar, M.; Asim, Z.; Alam, M. K.

    2016-01-01

    Objective: To determine and compare the cephalometric values among Pakistani males and females using commonly used sagittal skeletal measurements (ANB, Wits appraisal, Beta-angle) and newly developed cephalometric analyses (Yen-angle and W-angle). Study Design: Observational, cross-sectional study. Place and Duration of Study: Orthodontic Department of Baqai Medical University, Karachi, Pakistan, from August to October 2013. Methodology: A total of 209 pre-treatment lateral cephalometric radiographs of orthodontic patients were selected from departmental records, comprised of 92 males and 117 females. Radiographs were traced for measurements of ANB, Wits appraisal, Beta-angle, W-angle and Yen-angle. Patients were categorized into skeletal classes I, II, and III on the basis of performed measurements, incisor classification, and profile recorded from their records. Descriptive analysis was used to obtain median interquartile range in both the genders and Mann-Whitney U-test was used to observe gender dimorphism. Result: Skeletal class II was the most prevalent type of malocclusion. There were no difference in the obtained measurements between males and females except the Wits appraisal and Beta-angle in class II patients, which showed significant difference in values (p < 0.05). Conclusion: Pakistani population has no significant different difference in the craniofacial morphology of males and females, with the exception of Wits-appraisal and Beta-angle in class II cases. (author)

  2. Sagittal venous sinus thrombosis after cesarean section: a case report

    Directory of Open Access Journals (Sweden)

    Farideh Keypour

    2013-07-01

    Full Text Available Background: Cerebral venous thrombosis (CVT is uncommon after cesarean section. Although it can be a leading cause of maternal mortality. CVT may occur during pregnancy because of hypercoagulable states such as preeclampsia, thrombophilias, antiphospholipid antibody syndrome and sepsis.Case presentation: A 31 years old woman G2 Ab1 at 37 weeks gestational age with  premature rupture of membrane underwent cesarean section because breech presentation and preeclampsia. Spinal anesthesia was done for emergent cesarean section. On the second day after cesarean section, she developed headache, vomiting, focal neurologic deficits, paresthesia, blurred vision. Brain magnetic resonance imaging (MRI showed thrombosis in anterior half of superior sagittal sinus. Treatment consisted of anticoagulation.  Conclusion: Thrombophilias, pregnancy-related hypertension and cesarean section are the predisposing factors for thromboembolism. Unfractionated heparin and low molecular weight heparin (LMWs are effective drugs for thromboprophylaxis. It is vital to prevent venous thrombosis to reduce mortality during both intrapartum and postpartum periods. Consideration of cerebral venous thrombosis in similar cases is recommended.

  3. Assessment of Gender Dimorphism on Sagittal Cephalometry in Pakistani Population.

    Science.gov (United States)

    Qamruddin, Irfan; Alam, Mohammad Khursheed; Shahid, Fazal; Tanveer, Sadaf; Mukhtiar, Marvi; Asim, Zainab

    2016-05-01

    To determine and compare the cephalometric values among Pakistani males and females using commonly used sagittal skeletal measurements (ANB, Wits appraisal, Beta-angle) and newly developed cephalometric analyses (Yen-angle and W-angle). Observational, cross-sectional study. Orthodontic Department of Baqai Medical University, Karachi, Pakistan, from August to October 2013. Atotal of 209 pre-treatment lateral cephalometric radiographs of orthodontic patients were selected from departmental records, comprised of 92 males and 117 females. Radiographs were traced for measurements of ANB, Wits appraisal, Beta-angle, W-angle and Yen-angle. Patients were categorized into skeletal classes I, II, and III on the basis of performed measurements, incisor classification, and profile recorded from their records. Descriptive analysis was used to obtain median interquartile range in both the genders and Mann-Whitney U-test was used to observe gender dimorphism. Skeletal class II was the most prevalent type of malocclusion. There were no difference in the obtained measurements between males and females except the Wits appraisal and Beta-angle in class II patients, which showed significant difference in values (p < 0.05). Pakistani population has no significant different difference in the craniofacial morphology of males and females, with the exception of Wits-appraisal and Beta-angle in class II cases.

  4. Control rod housing alignment

    International Nuclear Information System (INIS)

    Dixon, R.C.; Deaver, G.A.; Punches, J.R.; Singleton, G.E.; Erbes, J.G.; Offer, H.P.

    1990-01-01

    This patent describes a process for measuring the vertical alignment between a hole in a core plate and the top of a corresponding control rod drive housing within a boiling water reactor. It comprises: providing an alignment apparatus. The alignment apparatus including a lower end for fitting to the top of the control rod drive housing; an upper end for fitting to the aperture in the core plate, and a leveling means attached to the alignment apparatus to read out the difference in angularity with respect to gravity, and alignment pin registering means for registering to the alignment pin on the core plate; lowering the alignment device on a depending support through a lattice position in the top guide through the hole in the core plate down into registered contact with the top of the control rod drive housing; registering the upper end to the sides of the hole in the core plate; registering the alignment pin registering means to an alignment pin on the core plate to impart to the alignment device the required angularity; and reading out the angle of the control rod drive housing with respect to the hole in the core plate through the leveling devices whereby the angularity of the top of the control rod drive housing with respect to the hole in the core plate can be determined

  5. Interference Alignment and Cancellation

    OpenAIRE

    Gollakota, Shyamnath; Perli, Samuel David; Katabi, Dina

    2009-01-01

    The throughput of existing MIMO LANs is limited by the number of antennas on the AP. This paper shows how to overcome this limit. It presents interference alignment and cancellation (IAC), a new approach for decoding concurrent sender-receiver pairs in MIMO networks. IAC synthesizes two signal processing techniques, interference alignment and interference cancellation, showing that the combination applies to scenarios where neither interference alignment nor cancellation applies alone. We sho...

  6. MUON DETECTORS: ALIGNMENT

    CERN Document Server

    G.Gomez

    2010-01-01

    Most of the work in muon alignment since December 2009 has focused on the geometry reconstruction from the optical systems and improvements in the internal alignment of the DT chambers. The barrel optical alignment system has progressively evolved from reconstruction of single active planes to super-planes (December 09) to a new, full barrel reconstruction. Initial validation studies comparing this full barrel alignment at 0T with photogrammetry provide promising results. In addition, the method has been applied to CRAFT09 data, and the resulting alignment at 3.8T yields residuals from tracks (extrapolated from the tracker) which look smooth, suggesting a good internal barrel alignment with a small overall offset with respect to the tracker. This is a significant improvement, which should allow the optical system to provide a start-up alignment for 2010. The end-cap optical alignment has made considerable progress in the analysis of transfer line data. The next set of alignment constants for CSCs will there...

  7. Tidal alignment of galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Blazek, Jonathan; Vlah, Zvonimir; Seljak, Uroš

    2015-08-01

    We develop an analytic model for galaxy intrinsic alignments (IA) based on the theory of tidal alignment. We calculate all relevant nonlinear corrections at one-loop order, including effects from nonlinear density evolution, galaxy biasing, and source density weighting. Contributions from density weighting are found to be particularly important and lead to bias dependence of the IA amplitude, even on large scales. This effect may be responsible for much of the luminosity dependence in IA observations. The increase in IA amplitude for more highly biased galaxies reflects their locations in regions with large tidal fields. We also consider the impact of smoothing the tidal field on halo scales. We compare the performance of this consistent nonlinear model in describing the observed alignment of luminous red galaxies with the linear model as well as the frequently used "nonlinear alignment model," finding a significant improvement on small and intermediate scales. We also show that the cross-correlation between density and IA (the "GI" term) can be effectively separated into source alignment and source clustering, and we accurately model the observed alignment down to the one-halo regime using the tidal field from the fully nonlinear halo-matter cross correlation. Inside the one-halo regime, the average alignment of galaxies with density tracers no longer follows the tidal alignment prediction, likely reflecting nonlinear processes that must be considered when modeling IA on these scales. Finally, we discuss tidal alignment in the context of cosmic shear measurements.

  8. A comparison of standard definitions and sagittal abdominal ...

    Science.gov (United States)

    Introduction: Metabolic syndrome (MeTS) is the cluster of several clinical symptoms that together represent the strongest risk factor for cardiovascular disease. The prevalence of MeTS in adolescents is difficult to estimate given that there are several, but no agreed upon definition of MeTS for this age group. It is important to estimate MeTS and identify at-risk adolescents early in order to provide effective interventions prior to the development of diabetes and coronary heart disease. Objective: Study objectives are to: (1) estimate the prevalence of MeTS in U.S. adolescents using three widely adopted definitions and (2) compare changes in prevalence of MeTS when utilizing sagittal abdominal diameter (SAD) as a component of MeTS. Methods: Data from U.S. adolescents ages 12–19 years (N=970) in the NHANES (2011–2014) were analyzed. MeTS standard definitions developed by Cook et al. (2003), deFerranti et al. (2007), and the International Disease Federation (IDF, 2007) were applied to estimate the sex-stratified, weighted prevalence of MeTS and its individual components (i.e., high waist circumference (WC), hypertension, blood lipid abnormalities, and high fasting blood glucose (FBG)). The definitions were modified by substituting SAD for WC, and weighted MeTS prevalence was re-estimated. Results: Regardless of gender and definition, abnormal blood lipids and high WC were the most prevalent MeTS components. For both sexes, estimated prevalence of componen

  9. SAGITTAL DIAMETER OF FORAMEN MAGNUM IN NORMAL POPULATION: AN MRI STUDY

    OpenAIRE

    Lakshmi

    2015-01-01

    Lower position of cerebellar tonsils was frequently noticed in Western studies. In some of the studies, sagittal diameter of foramen magnum was found to be larger in cases of Chiari malformation. However, there are no Indian studies for comparison. Our study was proposed to determine the standard values for sagittal diameter of foramen magnum in various age groups and both sexes. This gives a guideline for further studies in pathological conditions like Craniovertebral Junctional ...

  10. The Role of Proprioception in the Sagittal Setting of Anticipatory Postural Adjustments During Gait Initiation

    OpenAIRE

    Pereira Marcelo P.; Pelicioni Paulo H. Silva; Gobbi Lilian T.B.

    2015-01-01

    Purpose. Previous studies have studied the role of proprioception on the setting of anticipatory postural adjustments (APA) during gait initiation. However, these studies did not investigate the role of proprioception in the sagittal APA setting. We aimed to investigate the role of proprioception manipulation to induce APA sagittal adaptations on gait initiation. Methods. Fourteen healthy adults performed gait initiation without, and with, vibration applied before movement onset, and during m...

  11. Superior sagittal sinus thrombosis: a rare complication in a child with nephrotic syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Pirogovsky, A.; Adi, M.; Barzilai, N. [Dept. of Radiology, Kaplan Medical Center, Rehovot (Israel); Dagan, A.; Sinai, L.; Sthoeger, D. [Div. of Paediatrics, Kaplan Medical Center, Rehovot (Israel); Tabachnik, E. [Div. of Paediatrics, Kaplan Medical Center, Rehovot (Israel); Paediatric ICU, Kaplan Hospital, Rehovot (Israel)

    2001-10-01

    A 2-year-old boy with new-onset nephrotic syndrome developed recurrent vomiting, apathy and papilloedema. Superior sagittal sinus thrombosis was diagnosed on cranial CT and MRI. He gradually recovered after treatment with heparin, fresh frozen plasma and warfarin with complete resolution of the thrombosis after 1 month. Superior sagittal sinus thrombosis is an extremely rare complication of nephrotic syndrome in children. Early diagnosis is essential for institution of anticoagulation therapy and a successful outcome. (orig.)

  12. Superior sagittal sinus thrombosis: a rare complication in a child with nephrotic syndrome

    International Nuclear Information System (INIS)

    Pirogovsky, A.; Adi, M.; Barzilai, N.; Dagan, A.; Sinai, L.; Sthoeger, D.; Tabachnik, E.

    2001-01-01

    A 2-year-old boy with new-onset nephrotic syndrome developed recurrent vomiting, apathy and papilloedema. Superior sagittal sinus thrombosis was diagnosed on cranial CT and MRI. He gradually recovered after treatment with heparin, fresh frozen plasma and warfarin with complete resolution of the thrombosis after 1 month. Superior sagittal sinus thrombosis is an extremely rare complication of nephrotic syndrome in children. Early diagnosis is essential for institution of anticoagulation therapy and a successful outcome. (orig.)

  13. Sagittal Plane Knee Biomechanics and Vertical Ground Reaction Forces Are Modified Following ACL Injury Prevention Programs

    OpenAIRE

    Padua, Darin A.; DiStefano, Lindsay J.

    2009-01-01

    Context: Injuries to the anterior cruciate ligament (ACL) occur because of excessive loading on the knee. ACL injury prevention programs can influence sagittal plane ACL loading factors and vertical ground reaction force (VGRF). Objective: To determine the influence of ACL injury prevention programs on sagittal plane knee biomechanics (anterior tibial shear force, knee flexion angle/moments) and VGRF. Data Sources: The PubMed database was searched for studies published between January 1988 an...

  14. Influence of age and sagittal balance of the spine on the value of the pelvic incidence.

    Science.gov (United States)

    Jean, Legaye

    2014-07-01

    The pelvic incidence (PI) was recognized as the key factor of the sagittal balance of the spine. Its value was described own for each individual and unchanged during adulthood. To bring out the effect of the age and of a sagittal imbalance in the variability of the value of PI. 200 subjects with chronic low back pain due to sagittal imbalance were compared to 89 normal subjects. For each groups, the cases were divided according to the age (19-40, 6-40 years, over 60 years). The PI and the sagittal positional parameters were measured on large radiographs in standardized standing position. The correlation between age and PI was observed significant only for the >60 years cases. The mean values of PI were significantly greater for these cases. An increase of the value of PI was attributable to a twisting mobilization within the sacroiliac joint. It results from a forward projection of the gravity due to a sagittal disturbance and a pelvic compensatory backward rotation. This twisting into the sacroiliac joint was incriminated in the origin of chronic low back pain. The sagittal pelvi-spinal imbalance may be incriminated in the increasing of the value of PI by a painful destabilization sacro-iliac, with leads to an increasing of the value of PI.

  15. The longitudinal sagittal growth changes of maxilla and mandible according to quantitative cervical vertebral maturation.

    Science.gov (United States)

    Chen, Lili; Lin, Jiuxiang; Xu, Tianmin; Long, Xiaosi

    2009-04-01

    To investigate the longitudinal sagittal growth changes of maxilla and mandible according to the quantitative cervical vertebral maturation (QCVM) for adolescents with normal occlusion, mixed longitudinal data were used. The samples included 87 adolescents aged from 8 to 18 y old with normal occlusion (32 males, 55 females) selected from 901 candidates. Sequential lateral cephalograms and hand-wrist films were taken once a year, lasting for 6 y. The longitudinal sagittal growth changes of maxilla and mandible according to QCVM were measured. There were some significant differences between maxilla and mandible according to QCVM. The sagittal growth change of maxilla showed a trend towards high velocity-->decelerating velocity-->completing velocity from QCVM stage I to stage IV. The sagittal growth change of mandible showed a trend towards accelerating velocity-->high velocity-->decelerating velocity-->completing velocity from QCVM stage I to stage IV. With sagittal relationship, growth magnitude was almost the same between maxilla and mandible at QCVM stage I. At stage II the growth of mandible exceeded that of maxilla and growth in mandible continued at stages III and IV, while the maxilla ceased to grow. Growth magnitude was greater and the growth duration was longer with male mandible. It is concluded that the longitudinal sagittal growth changes of maxilla and mandible on the basis of QCVM is of value in the orthodontic practice.

  16. Tracking errors in tractography of the gastrocnemius muscle. A comparison between the transverse and sagittal planes

    International Nuclear Information System (INIS)

    Aoki, Takako; Tohdoh, Yukihiro; Tawara, Noriyuki; Okuwaki, Toru; Horiuchi, Akira; Itagaki, Takuma; Niitsu, Mamoru

    2010-01-01

    In scans taken in conventional direction, tracking errors may occur when using a streamline-based algorithm for the tractography of the gastrocnemius muscle. To solve errors in tracking, we applied tractography to the musculotendinous junction and performed fiber tracking on the gastrocnemius muscle of 10 healthy subjects with their written informed consent. We employed a spin-echo diffusion tensor imaging (SE-DTI) sequence with 6-direction diffusion gradient sensitization and acquired DTI images at 1.5 tesla using a body array coil with parallel imaging. We compared tractography obtained in the transverse and sagittal planes using anatomical reference and found that the gastrocnemius muscle and musculotendinous junction were significantly better visualized on sagittal scans and in 3 regions of interest. We utilized Mann-Whitney U-test to determine significant differences between rates of concordance (P 2 value of skeletal muscle is around 50 ms, and TE should be as short as possible. A streamline-based algorithm is based on the continuity of a vector. It is easy to take running of the muscle fiber in sagittal scan. Therefore, tracking error is hard to occur. In conclusion, sagittal scanning may be one way to eliminate tracking errors in the tractography of the gastrocnemius muscle. Tracking errors were smaller with sagittal scans than transverse scans, and sagittal scans allow better fiber tracking. (author)

  17. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    Gervasio Gomez

    The main progress of the muon alignment group since March has been in the refinement of both the track-based alignment for the DTs and the hardware-based alignment for the CSCs. For DT track-based alignment, there has been significant improvement in the internal alignment of the superlayers inside the DTs. In particular, the distance between superlayers is now corrected, eliminating the residual dependence on track impact angles, and good agreement is found between survey and track-based corrections. The new internal geometry has been approved to be included in the forthcoming reprocessing of CRAFT samples. The alignment of DTs with respect to the tracker using global tracks has also improved significantly, since the algorithms use the latest B-field mapping, better run selection criteria, optimized momentum cuts, and an alignment is now obtained for all six degrees of freedom (three spatial coordinates and three rotations) of the aligned DTs. This work is ongoing and at a stage where we are trying to unders...

  18. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    G.Gomez

    2011-01-01

    The Muon Alignment work now focuses on producing a new track-based alignment with higher track statistics, making systematic studies between the results of the hardware and track-based alignment methods and aligning the barrel using standalone muon tracks. Currently, the muon track reconstruction software uses a hardware-based alignment in the barrel (DT) and a track-based alignment in the endcaps (CSC). An important task is to assess the muon momentum resolution that can be achieved using the current muon alignment, especially for highly energetic muons. For this purpose, cosmic ray muons are used, since the rate of high-energy muons from collisions is very low and the event statistics are still limited. Cosmics have the advantage of higher statistics in the pT region above 100 GeV/c, but they have the disadvantage of having a mostly vertical topology, resulting in a very few global endcap muons. Only the barrel alignment has therefore been tested so far. Cosmic muons traversing CMS from top to bottom are s...

  19. Hole-Aligning Tool

    Science.gov (United States)

    Collins, Frank A.; Saude, Frank; Sep, Martin J.

    1996-01-01

    Tool designed for use in aligning holes in plates or other structural members to be joined by bolt through holes. Holes aligned without exerting forces perpendicular to planes of holes. Tool features screw-driven-wedge design similar to (but simpler than) that of some automotive exhaust-pipe-expanding tools.

  20. Alignement experience in STAR

    CERN Document Server

    Margetis, S; Lauret, J; Perevozchikov, V; Van Buren, G; Bouchef, J

    2007-01-01

    The STAR experiment at RHIC uses four layers of silicon strip and silicon drift detectors for secondary vertex reconstruction. An attempt for a direct charm meson measurement put stringent requirements on alignment and calibration. We report on recent alignment and drift velocity calibration work performed on the inner silicon tracking system.

  1. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    G. Gomez

    Since December, the muon alignment community has focused on analyzing the data recorded so far in order to produce new DT and CSC Alignment Records for the second reprocessing of CRAFT data. Two independent algorithms were developed which align the DT chambers using global tracks, thus providing, for the first time, a relative alignment of the barrel with respect to the tracker. These results are an important ingredient for the second CRAFT reprocessing and allow, for example, a more detailed study of any possible mis-modelling of the magnetic field in the muon spectrometer. Both algorithms are constructed in such a way that the resulting alignment constants are not affected, to first order, by any such mis-modelling. The CSC chambers have not yet been included in this global track-based alignment due to a lack of statistics, since only a few cosmics go through the tracker and the CSCs. A strategy exists to align the CSCs using the barrel as a reference until collision tracks become available. Aligning the ...

  2. The influence of computer-assisted surgery on rotational, coronal and sagittal alignment in revision total knee arthroplasty

    NARCIS (Netherlands)

    Meijer, Marrigje F; Stevens, Martin; Boerboom, Alexander L; Bulstra, Sjoerd K; Reininga, Inge Hf

    2014-01-01

    Background: Despite good results of primary total knee arthroplasty (TKA), the number of revision total knee arthroplasties (rTKAs) is rising. Proper implant position is essential, since malposition leads to worse clinical outcome. In rTKA most anatomical landmarks have disappeared because of

  3. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    G. Gomez

    2011-01-01

    A new set of muon alignment constants was approved in August. The relative position between muon chambers is essentially unchanged, indicating good detector stability. The main changes concern the global positioning of the barrel and of the endcap rings to match the new Tracker geometry. Detailed studies of the differences between track-based and optical alignment of DTs have proven to be a valuable tool for constraining Tracker alignment weak modes, and this information is now being used as part of the alignment procedure. In addition to the “split-cosmic” analysis used to investigate the muon momentum resolution at high momentum, a new procedure based on reconstructing the invariant mass of di-muons from boosted Zs is under development. Both procedures show an improvement in the momentum precision of Global Muons with respect to Tracker-only Muons. Recent developments in track-based alignment include a better treatment of the tails of residual distributions and accounting for correla...

  4. [Correlation between sagittal photogrammetric measurements of the soft tissue profile and dental arches measurements].

    Science.gov (United States)

    Diouf, Joseph Samba; Touré, Bécaye; Ndiaye, Marième; Badiane, Alpha; Diop-Bâ, Khady; Ngom, Papa Ibrahima; Diagne, Falou

    2015-12-01

    Sagittal soft-tissue analyses made from photographic records (sagittal photogrammetric analysis of the soft tissues) allow orthodontists to quantify the sagittal dimension and situation of the facial soft tissues. These tissues maintain close anatomical relationships with the underlying dental arches. However, little importance has been given to the description and the comparison of the sagittal soft tissue morphology according to dental arches parameters. The purpose of this study was to determine the correlation between the sagittal photogrammetric soft tissue profile and the dental arches measurements. A cross-sectional study was performed in a group of students. Standardized facial-profile photographs were taken with each student in natural head position, and relaxed lip posture. Photogrammetric parameters were measured on paper sheet using a graduated ruler. Dental arches measurements were also performed directly into the mouth with an electronic caliper. The strength of the association between sagittal photogrammetric soft tissue measurements and dental arches parameters was investigated by a Pearson's correlation. Results were regarded as significant at p=0.05. The lips protrusion parameters were significantly and positively correlated with the dental arch lengths. The overjet was significantly and positively correlated with Ls/Sn-Sm. The overbite was significantly and negatively correlated with the sagittal labial parameters Ls/N-Ort, Li/N-Ort, Ls-E, Li E, Ls-S, Li S, Ls/Sn-Sm and Li/Sn-Sm. The correlations found in this study show the importance of taking into account the soft tissue in the diagnosis and orthodontic treatment of patients. © EDP Sciences, SFODF, 2015.

  5. Biomechanical comparison of sagittal-parallel versus non-parallel pedicle screw placement.

    Science.gov (United States)

    Farshad, Mazda; Farshad-Amacker, Nadja A; Bachmann, Elias; Snedeker, Jess G; Schmid, Samuel L

    2014-11-01

    While convergent placement of pedicle screws in the axial plane is known to be more advantageous biomechanically, surgeons intuitively aim toward a parallel placement of screws in the sagittal plane. It is however not clear whether parallel placement of screws in the sagittal plane is biomechanically superior to a non-parallel construct. The hypothesis of this study is that sagittal non-parallel pedicle screws do not have an inferior initial pull-out strength compared to parallel placed screws. The established lumbar calf spine model was used for determination of pull-out strength in parallel and non-parallel intersegmental pedicle screw constructs. Each of six lumbar calf spines (L1-L6) was divided into three levels: L1/L2, L3/L4 and L5/L6. Each segment was randomly instrumented with pedicle screws (6/45 mm) with either the standard technique of sagittal parallel or non-parallel screw placement, respectively, under fluoroscopic control. CT was used to verify the intrapedicular positioning of all screws. The maximum pull-out forces and type of failure were registered and compared between the groups. The pull-out forces were 5,394 N (range 4,221 N to 8,342 N) for the sagittal non-parallel screws and 5,263 N (range 3,589 N to 7,554 N) for the sagittal-parallel screws (p = 0.838). Interlevel comparisons also showed no statistically significant differences between the groups with no relevant difference in failure mode. Non-parallel pedicle screws in the sagittal plane have at least equal initial fixation strength compared to parallel pedicle screws in the setting of the here performed cadaveric calf spine experiments.

  6. Alignment for CSR

    International Nuclear Information System (INIS)

    Wang Shoujin; Man Kaidi; Guo Yizhen; Cai Guozhu; Guo Yuhui

    2002-01-01

    Cooled Storage Ring of Heavy Ion Research Facility in Lanzhou (HIRFL-CSR) belongs to China great scientific project in China. The alignment for it is very difficult because of very large area and very high accuracy. For the special case in HIRFL-CSR, some new methods and new instruments are used, including the construction of survey control network, the usage of laser tracker, and CSR alignment database system with applications developed to store and analyze data. The author describes the whole procedure of CSR alignment

  7. Effect of one- or two-level posterior lumbar interbody fusion on global sagittal balance.

    Science.gov (United States)

    Cho, Jae Hwan; Joo, Youn-Suk; Lim, Cheongsu; Hwang, Chang Ju; Lee, Dong-Ho; Lee, Choon Sung

    2017-12-01

    Sagittal imbalance is associated with poor clinical outcomes in patients with degenerative lumbar disease. However, there is no consensus on the impact of posterior lumbar interbody fusion (PLIF) on local and global sagittal balance. To reveal the effect of one- or two-level PLIF on global sagittal balance. A retrospective case-control study. This study included 88 patients who underwent a one- or two-level PLIF for spinal stenosis with spondylolisthesis. Clinical and radiological parameters were measured pre- and postoperatively. All patients were followed up for >2 years. Clinical outcomes included a visual analog scale, Oswestry Disability Index, and EuroQol 5-dimension questionnaire (EQ-5D). Radiological parameters were measured using whole-spine standing lateral radiographs. Fusion, loosening, subsidence rates, and adverse events were also evaluated. Patients were divided into two groups according to their preoperative C7-S1 sagittal vertical axis (SVA): Group N: SVA≤5 cm vs Group I: SVA>5 cm; they were also divided according to postoperative changes in C7-S1 SVA. Clinical and radiological outcomes were compared between the groups. All clinical outcomes and radiological parameters improved postoperatively. C7-S1 SVA improved (-1.6 cm) after L3-L5 fusion, but it was compromised (+3.6 cm) after L4-S1 fusion (p=.001). Preoperative demographic and clinical data showed no difference except in the anxiety or depression domain of EQ-5D. No differences were found in postoperative clinical outcomes. Lumbar lordosis, pelvic tilt, and thoracic kyphosis slightly improved in Group N, whereas C7-S1 SVA decreased from 9.5 cm to 3.8 cm (pfusion (L3-L5 vs L4-S1, p=.033). Global sagittal balance improved after short-level lumbar fusion surgery in patients having spinal stenosis with spondylolisthesis who showed preoperative sagittal imbalance. Restoration of sagittal balance predominantly occurred after L3-L4, L4-L5, or L3-L5 PLIF. However, no such restoration was

  8. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    G.Gomez

    Since September, the muon alignment system shifted from a mode of hardware installation and commissioning to operation and data taking. All three optical subsystems (Barrel, Endcap and Link alignment) have recorded data before, during and after CRAFT, at different magnetic fields and during ramps of the magnet. This first data taking experience has several interesting goals: •    study detector deformations and movements under the influence of the huge magnetic forces; •    study the stability of detector structures and of the alignment system over long periods, •    study geometry reproducibility at equal fields (specially at 0T and 3.8T); •    reconstruct B=0T geometry and compare to nominal/survey geometries; •    reconstruct B=3.8T geometry and provide DT and CSC alignment records for CMSSW. However, the main goal is to recons...

  9. Biaxial magnetic grain alignment

    International Nuclear Information System (INIS)

    Staines, M.; Genoud, J.-Y.; Mawdsley, A.; Manojlovic, V.

    2000-01-01

    Full text: We describe a dynamic magnetic grain alignment technique which can be used to produce YBCO thick films with a high degree of biaxial texture. The technique is, however, generally applicable to preparing ceramics or composite materials from granular materials with orthorhombic or lower crystal symmetry and is therefore not restricted to superconducting applications. Because magnetic alignment is a bulk effect, textured substrates are not required, unlike epitaxial coated tape processes such as RABiTS. We have used the technique to produce thick films of Y-247 on untextured silver substrates. After processing to Y-123 the films show a clear enhancement of critical current density relative to identically prepared untextured or uniaxially textured samples. We describe procedures for preparing materials using magnetic biaxial grain alignment with the emphasis on alignment in epoxy, which can give extremely high texture. X-ray rocking curves with FWHM of as little as 1-2 degrees have been measured

  10. Alignment of CEBAF cryomodules

    International Nuclear Information System (INIS)

    Schneider, W.J.; Bisognano, J.J.; Fischer, J.

    1993-06-01

    CEBAF, the Continuous Electron Beam Accelerator Facility, when completed, will house a 4 GeV recirculating accelerator. Each of the accelerator's two linacs contains 160 superconducting radio frequency (SRF) 1497 MHz niobium cavities in 20 cryomodules. Alignments of the cavities within the cryomodule with respect to beam axis is critical to achieving the optimum accelerator performance. This paper discusses the rationale for the current specification on cavity mechanical alignment: 2 mrad (rms) applied to the 0.5 m active length cavities. We describe the tooling that was developed to achieve the tolerance at the time of cavity pair assembly, to preserve and integrate alignment during cryomodule assembly, and to translate alignment to appropriate installation in the beam line

  11. Kinematic analysis of leg alignment during conventional versus navigated total knee arthroplasty: Initial results of a prospective study

    Directory of Open Access Journals (Sweden)

    Chih-Wei Chang

    2012-09-01

    Full Text Available Current kinematic navigation systems provide real-time spatial analyses of leg alignments during total knee arthroplasty (TKA instead of delayed radiographic verification after surgery. A prospective study was conducted to investigate leg alignments of TKAs that underwent different surgical guidance [intramedullary (IM jig-based vs. navigation-assisted] using a kinematic navigation system. Since May 2007, patients admitted for primary TKA were considered for inclusion. Within 6 months, 38 sets of intraoperative analyses on the operated legs have been performed. Excluding seven unreliable data sets, 15 conventional IM jig-based TKAs and 16 navigation-assisted TKAs were available. The leg alignments in maximum knee extension were retrieved for comparison. Although similar final coronal alignments were accurately achieved in both groups (0.21 valgus in the IM group vs. 0.17 valgus in the NA group, p=0.993, a more flexed sagittal axis was constructed with conventional IM jigs (1.93 flexion in the IM group vs. 0.58 extension in the NA group, p<0.05. The study suggests that comparable coronal precision could be achieved with conventional IM jigs by trained surgeons, although computer-assisted navigation is a documented method to restore accurate alignment. Different sagittal alignments observed in this study indicate the inherent discrepancy between different surgical guides as well as their according concepts.

  12. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    G. Gomez

    2012-01-01

      A new muon alignment has been produced for 2012 A+B data reconstruction. It uses the latest Tracker alignment and single-muon data samples to align both DTs and CSCs. Physics validation has been performed and shows a modest improvement in stand-alone muon momentum resolution in the barrel, where the alignment is essentially unchanged from the previous version. The reference-target track-based algorithm using only collision muons is employed for the first time to align the CSCs, and a substantial improvement in resolution is observed in the endcap and overlap regions for stand-alone muons. This new alignment is undergoing the approval process and is expected to be deployed as part of a new global tag in the beginning of December. The pT dependence of the φ-bias in curvature observed in Monte Carlo was traced to a relative vertical misalignment between the Tracker and barrel muon systems. Moving the barrel as a whole to match the Tracker cures this pT dependence, leaving only the &phi...

  13. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    S. Szillasi

    2013-01-01

    The CMS detector has been gradually opened and whenever a wheel became exposed the first operation was the removal of the MABs, the sensor structures of the Hardware Barrel Alignment System. By the last days of June all 36 MABs have arrived at the Alignment Lab at the ISR where, as part of the Alignment Upgrade Project, they are refurbished with new Survey target holders. Their electronic checkout is on the way and finally they will be recalibrated. During LS1 the alignment system will be upgraded in order to allow more precise reconstruction of the MB4 chambers in Sector 10 and Sector 4. This requires new sensor components, so called MiniMABs (pictured below), that have already been assembled and calibrated. Image 6: Calibrated MiniMABs are ready for installation For the track-based alignment, the systematic uncertainties of the algorithm are under scrutiny: this study will enable the production of an improved Monte Carlo misalignment scenario and to update alignment position errors eventually, crucial...

  14. Curriculum Alignment Research Suggests that Alignment Can Improve Student Achievement

    Science.gov (United States)

    Squires, David

    2012-01-01

    Curriculum alignment research has developed showing the relationship among three alignment categories: the taught curriculum, the tested curriculum and the written curriculum. Each pair (for example, the taught and the written curriculum) shows a positive impact for aligning those results. Following this, alignment results from the Third…

  15. Component alignment and functional outcome following computer assisted and jig based total knee arthroplasty.

    Science.gov (United States)

    Lad, Dnyanesh G; Thilak, Jai; Thadi, Mohan

    2013-01-01

    Incorrect positioning of the implant and improper alignment of the limb following total knee arthroplasty (TKA) can lead to rapid implant wear, loosening, and suboptimal function. Studies suggest that alignment errors of > 3° are associated with rapid failure and less satisfactory function. Computer navigated systems have been developed to enhance precision in instrumentation during surgery. The aim of the study was to compare component alignment following computer assisted surgery (CAS) and jig based TKA as well as functional outcome. This is a prospective study of 100 knees to compare computer-assisted TKA and jig-based surgery in relation to femoral and tibial component alignment and functional outcome. The postoperative x-rays (anteroposterior and lateral) of the knee and CT scanogram from hip to foot were obtained. The coronal alignment of the femoral and tibial components and rotational alignment of femoral component was calculated. Knee society score at 24 months was used to assess the function. Results of our study show that mean placement of the tibial component in coronal plane (91.3037°) and sagittal planes (3.6058°) was significantly better with CAS. The difference was statistically insignificant in case of mean coronal alignment of the femoral components (90.34210° in navigation group and 90.5444° in jig group) and in case of the mean femoral condylar twist angle (external rotation 2.3406° in navigation group versus 2.3593° in jig group). A significantly improved placement of the component was found in the coronal and sagittal planes of the tibial component by CAS. The placement of the components in the other planes was comparable with the values recorded in the jig-based surgery group. Functional outcome was not significantly different.

  16. Establishing Cephalometric Norms using Sagittal and Vertical Occlusal Cephalometric Analysis of Pancherz for Dakshina Kannada Children.

    Science.gov (United States)

    Sahitya, M; Shashidhar, E P; Chidanandeswara, G C; Shetty, Sharath Kumar B; Kumar, Y Mahesh

    2015-07-01

    The purpose of this study was to establish norms for the sagittal occlusal (SO) and vertical occlusal (VO) cephalometric analyses of Pancherz for Dakshina Kannada children and to analyze and compare the difference between boys and girls of same age group (10-14 years). Two hundred and sixty-three (132 boys and 131 girls) children of Dakshina Kannada were included in this study. Lateral cephalometric radiographs of children belonging to the age group of 10-14 years were taken. Dental lateral cephalometric radiographs were obtained and these cephalometric radiographs were then manually traced. All the parameters considered in the Pancherz analysis were considered while establishing the norms for Dakshina Kannada children. Statistically significant sex differences were found for 9 of 11 parameters in the sagittal occlusal analysis, and 10 of 10 in the Vertical occlusal analysis. For the sagittal and Vertical occlusal analyses of Pancherz a separate sex-specific standards are needed for Dakshina Kannada children.

  17. Splintage in the treatment of sagittal band incompetence and extensor tendon subluxation.

    Science.gov (United States)

    Peelman, J; Markiewitz, A; Kiefhaber, T; Stern, P

    2015-03-01

    This study assessed the success of splintage for traumatic and atraumatic sagittal band incompetence and its relationship to the duration of symptoms before treatment. A retrospective review of all patients with sagittal band incompetence treated with splintage was performed. All patients had extensor tendon subluxation on physical examination. Ninety-two patients were included: 68 traumatic and 24 atraumatic. Subluxation resolved with splintage in 77 patients. Traumatic tendon subluxation resolved in 95% of acute injuries, 100% of subacute injuries, and 67% of chronic injures. Atraumatic tendon subluxation resolved in 100% of patients with acute presentation, 67% of patients with subacute presentation, and 57% of patients with chronic presentation. Surgery was rarely required. Splintage proved very effective for acute sagittal band incompetence, regardless of causation, but decreased in efficiency with chronicity. Level 4. © The Author(s) 2014.

  18. Identification and treatment of osteochondritis dissecans of the distal sagittal ridge of the third metacarpal bone.

    Science.gov (United States)

    Wright, I M; Minshall, G J

    2014-09-01

    Osteochondritis dissecans (OCD) of the distal sagittal ridge of the third metacarpal bone (McIII) has not previously been described in the literature. To describe the clinical, radiological and arthroscopic features of OCD of the distal sagittal ridge of the McIII and to report outcome in a series of cases. Retrospective case series. Case records and images of horses with OCD of the distal sagittal ridge of the McIII admitted to a single referral centre between February 2006 and February 2013 were reviewed. Follow-up information was obtained by telephone questionnaire and/or racing performance. Osteochondritis dissecans of the distal sagittal ridge of the McIII was found in 16 lame horses; 9 unilaterally and 7 bilaterally. Lesions were consistently identified with flexed lateromedial radiographs and in 21 joints in dorsopalmar projections also. These were arthroscopically accessible from the dorsal compartment with metacarpophalangeal joints maximally flexed. This permitted fragment removal and lesion debridement. Thirteen of 14 horses with follow-up of ≥12 months post surgery performed athletically including 11 of 12 Thoroughbreds that raced. Unlike more proximal lesions, OCD of the distal sagittal ridge appears to affect the McIII preferentially. Lesions were identified on dorsopalmar and flexed lateromedial radiographs only and are amenable to arthroscopic surgery. Clinicians should be aware of the potential for OCD to affect the distal sagittal ridge of the McIII together with the radiographic projections needed to identify its presence. A modified arthroscopic approach to the dorsal metacarpophalangeal joint is necessary in order to access lesions. © 2013 EVJ Ltd.

  19. Lumbar sagittal contour after posterior interbody fusion: threaded devices alone versus vertical cages plus posterior instrumentation.

    Science.gov (United States)

    Klemme, W R; Owens, B D; Dhawan, A; Zeidman, S; Polly, D W

    2001-03-01

    An observational radiographic study examining lumbar sagittal contour of patients undergoing posterior interbody arthrodesis. To compare operative alterations of lumbar sagittal contour after posterior interbody fusion using threaded interbody devices alone versus vertical cages combined with posterior compression instrumentation. Technique-related alterations of lumbar sagittal contour during interbody arthrodesis have received little attention in the spinal literature. Standing lumbar radiographs were measured for preoperative and postoperative segmental lordosis at levels undergoing posterior interbody arthrodesis using either stand-alone side-by-side threaded devices or vertical cages combined with posterior transpedicular compression instrumentation. Sagittal plane segmental correction (or loss of correction) was calculated and statistically compared. The radiographs of 30 patients (34 spinal segments) undergoing lumbar or lumbosacral arthrodesis were compared. Seventeen patients (18 segments) had undergone interbody fusion using threaded cages,whereas 13 patients (16 segments) underwent fusion using vertically oriented mesh cages combined with posterior compression instrumentation. Preoperative segmental lordosis averaged 8 degrees for both groups. For patients undergoing fusion with threaded cages, there was a mean lordotic loss of 3 degrees/segment. For patients undergoing fusion with vertically oriented mesh cages combined with posterior compression instrumentation,there was a mean lordotic gain of 5 degrees/segment. This difference in segmental sagittal plane contour was highly significant (P = 0.00). Threaded fusion devices placed under interbody distraction with the endplates parallel fail to preserve or reestablish segmental lordosis. Vertical cages, however, when combined with posterior compression instrumentation, not only maintain segmental lordosis, but also can correct sagittal plane deformity.

  20. RNA Structural Alignments, Part I

    DEFF Research Database (Denmark)

    Havgaard, Jakob Hull; Gorodkin, Jan

    2014-01-01

    Simultaneous alignment and secondary structure prediction of RNA sequences is often referred to as "RNA structural alignment." A class of the methods for structural alignment is based on the principles proposed by Sankoff more than 25 years ago. The Sankoff algorithm simultaneously folds and aligns...

  1. Surgical Access to a Complex Composite Odontoma via Sagittal Split Osteotomy of the Mandible

    Science.gov (United States)

    Periasamy, Senthilnathan; Devadoss, Poorna; Kumar, Santhosh P

    2017-01-01

    This case report presents the removal of complex composite odontoma in a young patient in the right body of mandible via the unilateral sagittal splitting of the mandible. This article shows that sagittal split osteotomy of the mandible can be very useful to access various pathologies in the body, angle, and ramus of the mandible and to navigate lesions that are in proximity to the inferior alveolar nerve. This technique also helps in avoiding postoperative morbidity when compared to other conventional surgical approaches. It can be used to remove large cysts, benign non-infiltrative tumours of the mandible, odontogenic myxoma, large odontoma, and deeply impacted lower third molars. PMID:29441249

  2. [The theoretical substantiation of myofunctional correction of sagittal occlusion abnormalities and temporomandibular joint dysfunction].

    Science.gov (United States)

    Danilova, M A; Ishmurzin, P V; Zakharov, S V

    2012-01-01

    Simulation in 3D-model of skeletal forms of sagittal malocclusion revealed tendency in tonus' modification of muscles of mastication in formation of distal and mesial occlusion. It's shown that distal occlusion is characterized by hypotonic condition of muscles of mastication, except posterior fibers of temporal muscle. Mesial occlusion is characterized by complex combination of muscle tone with prevalence of hypotonic condition of anterior fibers of temporal muscle, superficial portion of masseter muscle and medial pterygoid muscle. We have detected that using of myofunctional devices in treatment of sagittal malocclusion, temporomandibular joint dysfunction promotes of tone increasing of muscles of mastication.

  3. Normal anatomy of the female pelvis in axial, coronal, and sagittal planes demonstrated with reformatted CT

    International Nuclear Information System (INIS)

    Constant, O.C.; Cooke, J.C.; Parsons, C.A.

    1987-01-01

    Axial CT is used in assessing gynecologic malignancies. Accurate delineation of local tumor extent in carcinoma of the cervix is important in initial staging and in planning subsequent management. A modified scanning technique produces reformatted coronal and sagittal images, which demonstrate additional valuable information about the cardinal ligaments, parametria, ureters, boundaries between the cervix, bladder, and rectum, and extension to vagina and uterus. This information is illustrated by representative axial, coronal, and sagittal scans. Familiarity with normal appearances is essential to allow correct interpretation of pathology

  4. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    Gervasio Gomez

    2012-01-01

      The new alignment for the DT chambers has been successfully used in physics analysis starting with the 52X Global Tag. The remaining main areas of development over the next few months will be preparing a new track-based CSC alignment and producing realistic APEs (alignment position errors) and MC misalignment scenarios to match the latest muon alignment constants. Work on these items has been delayed from the intended timeline, mostly due to a large involvement of the muon alignment man-power in physics analyses over the first half of this year. As CMS keeps probing higher and higher energies, special attention must be paid to the reconstruction of very-high-energy muons. Recent muon POG reports from mid-June show a φ-dependence in curvature bias in Monte Carlo samples. This bias is observed already at the tracker level, where it is constant with muon pT, while it grows with pT as muon chamber information is added to the tracks. Similar studies show a much smaller effect in data, at le...

  5. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    M. Dallavalle

    2013-01-01

    A new Muon misalignment scenario for 2011 (7 TeV) Monte Carlo re-processing was re-leased. The scenario is based on running of standard track-based reference-target algorithm (exactly as in data) using single-muon simulated sample (with the transverse-momentum spectrum matching data). It used statistics similar to what was used for alignment with 2011 data, starting from an initially misaligned Muon geometry from uncertainties of hardware measurements and using the latest Tracker misalignment geometry. Validation of the scenario (with muons from Z decay and high-pT simulated muons) shows that it describes data well. The study of systematic uncertainties (dominant by now due to huge amount of data collected by CMS and used for muon alignment) is finalised. Realistic alignment position errors are being obtained from the estimated uncertainties and are expected to improve the muon reconstruction performance. Concerning the Hardware Alignment System, the upgrade of the Barrel Alignment is in progress. By now, d...

  6. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    G. Gomez

    2010-01-01

    For the last three months, the Muon Alignment group has focussed on providing a new, improved set of alignment constants for the end-of-year data reprocessing. These constants were delivered on time and approved by the CMS physics validation team on November 17. The new alignment incorporates several improvements over the previous one from March for nearly all sub-systems. Motivated by the loss of information from a hardware failure in May (an entire MAB was lost), the optical barrel alignment has moved from a modular, super-plane reconstruction, to a full, single loop calculation of the entire geometry for all DTs in stations 1, 2 and 3. This makes better use of the system redundancy, mitigating the effect of the information loss. Station 4 is factorised and added afterwards to make the system smaller (and therefore faster to run), and also because the MAB calibration at the MB4 zone is less precise. This new alignment procedure was tested at 0 T against photogrammetry resulting in precisions of the order...

  7. FMIT alignment cart

    International Nuclear Information System (INIS)

    Potter, R.C.; Dauelsberg, L.B.; Clark, D.C.; Grieggs, R.J.

    1981-01-01

    The Fusion Materials Irradiation Test (FMIT) Facility alignment cart must perform several functions. It must serve as a fixture to receive the drift-tube girder assembly when it is removed from the linac tank. It must transport the girder assembly from the linac vault to the area where alignment or disassembly is to take place. It must serve as a disassembly fixture to hold the girder while individual drift tubes are removed for repair. It must align the drift tube bores in a straight line parallel to the girder, using an optical system. These functions must be performed without violating any clearances found within the building. The bore tubes of the drift tubes will be irradiated, and shielding will be included in the system for easier maintenance

  8. Improving tibial component coronal alignment during total knee arthroplasty with use of a tibial planing device.

    Science.gov (United States)

    Patil, Shantanu; D'Lima, Darryl D; Fait, James M; Colwell, Clifford W

    2007-02-01

    The outcomes of knee arthroplasty have been shown to be affected by component alignment. Intramedullary and extramedullary alignment instrumentation are fairly effective for achieving the desired mean tibial component coronal alignment. However, there are outliers representing >3 degrees of varus or valgus alignment with respect to the anatomic tibial shaft axis. We measured the efficacy of a custom tibial planing device for reducing the outliers in tibial alignment. We designed a tibial planing tool in an effort to improve tibial alignment. In one cohort (100 knees), we used traditional intramedullary alignment instrumentation to make the tibial bone cut. In a second cohort (120 knees), we used intramedullary alignment instrumentation to make the cut and also used a custom tool to check the cut and to correct an inexact cut. Tibial tray alignment relative to the long axis of the tibial shaft was measured in the coronal and sagittal planes on postoperative radiographs. The target coronal alignment was 90 degrees with respect to the tibial shaft axis (with alignment). A total of 100 anteroposterior radiographs and sixty-five lateral radiographs were analyzed for the group that was treated with traditional instrumentation alone, and a total of 120 anteroposterior radiographs and fifty-five lateral radiographs were analyzed for the group that was treated with use of the custom tibial planing device. The mean coronal alignment of the tibial component was 89.5 degrees +/- 2.1 degrees in the group that was treated with traditional instrumentation alone and 89.6 degrees +/- 1.4 degrees in the group that was treated with use of the custom planing device. Although the mean coronal alignment was not significantly different, the number of outliers was substantially reduced when the custom planing device was used. All 120 components that had been aligned with use of the custom planing device were within 3 degrees of the target coronal alignment, compared with only eighty

  9. MUSE optical alignment procedure

    Science.gov (United States)

    Laurent, Florence; Renault, Edgard; Loupias, Magali; Kosmalski, Johan; Anwand, Heiko; Bacon, Roland; Boudon, Didier; Caillier, Patrick; Daguisé, Eric; Dubois, Jean-Pierre; Dupuy, Christophe; Kelz, Andreas; Lizon, Jean-Louis; Nicklas, Harald; Parès, Laurent; Remillieux, Alban; Seifert, Walter; Valentin, Hervé; Xu, Wenli

    2012-09-01

    MUSE (Multi Unit Spectroscopic Explorer) is a second generation VLT integral field spectrograph (1x1arcmin² Field of View) developed for the European Southern Observatory (ESO), operating in the visible wavelength range (0.465-0.93 μm). A consortium of seven institutes is currently assembling and testing MUSE in the Integration Hall of the Observatoire de Lyon for the Preliminary Acceptance in Europe, scheduled for 2013. MUSE is composed of several subsystems which are under the responsibility of each institute. The Fore Optics derotates and anamorphoses the image at the focal plane. A Splitting and Relay Optics feed the 24 identical Integral Field Units (IFU), that are mounted within a large monolithic instrument mechanical structure. Each IFU incorporates an image slicer, a fully refractive spectrograph with VPH-grating and a detector system connected to a global vacuum and cryogenic system. During 2011, all MUSE subsystems were integrated, aligned and tested independently in each institute. After validations, the systems were shipped to the P.I. institute at Lyon and were assembled in the Integration Hall This paper describes the end-to-end optical alignment procedure of the MUSE instrument. The design strategy, mixing an optical alignment by manufacturing (plug and play approach) and few adjustments on key components, is presented. We depict the alignment method for identifying the optical axis using several references located in pupil and image planes. All tools required to perform the global alignment between each subsystem are described. The success of this alignment approach is demonstrated by the good results for the MUSE image quality. MUSE commissioning at the VLT (Very Large Telescope) is planned for 2013.

  10. MaxAlign: maximizing usable data in an alignment

    DEFF Research Database (Denmark)

    Oliveira, Rodrigo Gouveia; Sackett, Peter Wad; Pedersen, Anders Gorm

    2007-01-01

    the alignment prior to such analyses. Specifically, it maximizes the number of nucleotide (or amino acid) symbols that are present in gap-free columns - the alignment area - by selecting the optimal subset of sequences to exclude from the alignment. MaxAlign can be used prior to phylogenetic and bioinformatical......Align. In this paper we also introduce a new simple measure of tree similarity, Normalized Symmetric Similarity (NSS) that we consider useful for comparing tree topologies. CONCLUSION: We demonstrate how MaxAlign is helpful in detecting misaligned or defective sequences without requiring manual inspection. We also...

  11. Comparative Study of Skeletal Stability between Postoperative Skeletal Intermaxillary Fixation and No Skeletal Fixation after Bilateral Sagittal Split Ramus Osteotomy

    DEFF Research Database (Denmark)

    Hartlev, Jens; Godtfredsen, Erik; Andersen, Niels Trolle

    2014-01-01

    OBJECTIVES: The purpose of the present study was to evaluate skeletal stability after mandibular advancement with bilateral sagittal split osteotomy. MATERIAL AND METHODS: Twenty-six patients underwent single-jaw bilateral sagittal split osteotomy (BSSO) to correct skeletal Class II malocclusion....

  12. A genome-wide association study identifies susceptibility loci for nonsyndromic sagittal craniosynostosis near BMP2 and within BBS9

    NARCIS (Netherlands)

    Justice, C.M.; Yagnik, G.; Kim, Y.; Peter, I.; Jabs, E.W.; Erazo, M.; Ye, X.; Ainehsazan, E.; Shi, L.; Cunningham, M.L.; Kimonis, V.; Roscioli, T.; Wall, S.A.; Wilkie, A.O.; Stoler, J.; Richtsmeier, J.T.; Heuze, Y.; Sanchez-Lara, P.A.; Buckley, M.F.; Druschel, C.M.; Mills, J.L.; Caggana, M.; Romitti, P.A.; Kay, D.M.; Senders, C.; Taub, P.J.; Klein, O.D.; Boggan, J.; Zwienenberg-Lee, M.; Naydenov, C.; Kim, J.; Wilson, A.F.; Boyadjiev, S.A.

    2012-01-01

    Sagittal craniosynostosis is the most common form of craniosynostosis, affecting approximately one in 5,000 newborns. We conducted, to our knowledge, the first genome-wide association study for nonsyndromic sagittal craniosynostosis (sNSC) using 130 non-Hispanic case-parent trios of European

  13. Cost, operation and hospitalization times in distraction osteogenesis versus sagittal split osteotomy

    NARCIS (Netherlands)

    van Strijen, P. J.; Breuning, K. H.; Becking, A. G.; Perdijk, F. B. T.; Tuinzing, D. B.

    2003-01-01

    Distraction osteogenesis in 'common' surgical orthodontics is mentioned as an alternative for conventional sagittal split osteotomy. After a 'learning curve' in the surgical skills of distraction, the two techniques can be compared concerning time and cost aspects. Forty-seven patients (male n=28,

  14. An Assessment of Correlation between Dermatoglyphic Patterns and Sagittal Skeletal Discrepancies.

    Science.gov (United States)

    George, Susha Miriam; Philip, Biju; Madathody, Deepika; Mathew, Manu; Paul, Jose; Dlima, Johnson Prakash

    2017-03-01

    Investigators over years have been fascinated by dermatoglyphic patterns which has led to the development of dermatoglyphics as a science with numerous applications in various fields other than being the best and most widely used method for personal identification. To assess the correlation between dermatoglyphic patterns and sagittal skeletal discrepancies. A total of 180 patients, aged 18-40 years, were selected from those who attended the outpatient clinic of the Deparment of Orthodontics and Dentofacial Orthopedics, Mar Baselios Dental College, Kothamangalam, Kerala, India. The fingerprints of both hands were taken by ink and stamp method after proper hand washing. The patterns of arches, loops and whorls in fingerprints were assessed. The total ridge count was also evaluated. Data was also sent to the fingerprint experts for expert evaluation. The sagittal jaw relation was determined from the patient's lateral cephalogram. The collected data was then statistically analyzed using Chi-square tests, ANOVA and Post-hoc tests and a Multinomial regression prediction was also done. A significant association was observed between the dermatoglyphic pattern exhibited by eight fingers and the sagittal skeletal discrepancies (pdermatoglyphic patterns and sagittal skeletal discrepancies. Dermatoglyphics could serve as a cost effective screening tool of these craniofacial problems.

  15. [Progressive Intracranial Hypertension due to Superior Sagittal Sinus Thrombosis Following Mild Head Trauma: A Case Report].

    Science.gov (United States)

    Suto, Yuta; Maruya, Jun; Watanabe, Jun; Nishimaki, Keiichi

    2015-07-01

    Cerebral venous sinus thrombosis after mild head trauma without skull fracture or intracranial hematoma is exceptionally rare. We describe an unusual case of progressive intracranial hypertension due to superior sagittal sinus thrombosis following mild head trauma. A 17-year-old boy presented with nape pain a day after a head blow during a gymnastics competition (backward double somersault). On admission, he showed no neurological deficit. CT scans revealed no skull fractures, and there were no abnormalities in the brain parenchyma. However, his headache worsened day-by-day and he had begun to vomit. Lumbar puncture was performed on Day 6, and the opening pressure was 40 cm of water. After tapping 20 mL, he felt better and the headache diminished for a few hours. MR venography performed on Day 8 revealed severe flow disturbance in the posterior third of the superior sagittal sinus with multiple venous collaterals. Because of the beneficial effects of lumbar puncture, we decided to manage his symptoms of intracranial hypertension conservatively with repeated lumbar puncture and administration of glycerol. After 7 days of conservative treatment, his symptoms resolved completely, and he was discharged from the hospital. Follow-up MR venography performed on Day 55 showed complete recanalization of the superior sagittal sinus. The exact mechanism of sinus thrombosis in this case is not clear, but we speculate that endothelial damage caused by shearing stress because of strong rotational acceleration or direct impact to the superior sagittal sinus wall may have initiated thrombus formation.

  16. Investigation of reconstruction conditions in sagittal-plane multiplanar reconstruction of the temporal bone

    International Nuclear Information System (INIS)

    Suzuki, Miyako; Yoshikawa, Hiroshi; Hosokawa, Akira; Ichikawa, Ginichiro; Kobayashi, Kenichi; Ando, Ichiro

    2002-01-01

    In recent years, it has become possible to quickly obtain a large amount of 3D data with high continuity by helical CT scanning, in which the body is scanned continuously in a helical fashion. MPR (multiplanar reconstruction) can be performed using this data to generate images in arbitrary sectional planes, making it possible to obtain sagittal-plane images of the highest quality, which is useful for surgical planning. However, the procedures involved are rather complicated. Therefore, this study was conducted to investigate conditions for standardization of sagittal-plane MPR examinations performed using Xvigor CT scanners and Xtension. The results showed that a slice interval of 1 mm, no imaging filter, a zooming factor of 1.5, a window level of 350, and a window width of 3500 are the optimal imaging conditions. The stapes can be visualized in 70% of cases with sagittal-plane MPR based on axial images, and can be recognized at surgery in 75% or more of cases. Images of consistent quality can be obtained by standardizing the conditions for sagittal-plane MPR, which should prove advantageous in the clinical setting. (author)

  17. Direct sagittal CT scanning in the diagnosis of pituitary fossa tumours and posterior fossa pathology

    International Nuclear Information System (INIS)

    Podlas, H.

    1981-01-01

    Two independent methods are presented for multidirectional CT scanning of the brain using the Philips Tomoscan 300. The advantages in scanning pituitary fossa tumours and pathology of the posterior fossa are discussed. No additional software or modifications are required. Direct sagittal scanning is particularly advantageous for accurate assessment of the size of pituitary tumours and intrasellar lesions requiring surgical intervention or radiation therapy. (Auth.)

  18. The Association between Maxillomandibular Sagittal Relationship and Pharyngeal Airway Passage Dimensions

    Directory of Open Access Journals (Sweden)

    Madhurima Nanda

    2012-01-01

    Conclusion : Sagittal skeletal pattern had a close association between the pharyngeal airway passage and the dimensions of the pharyngeal airway passage. The dimensions of pharyngeal airway passage were decreased from Class III to Class I and Class I to Class II subjects.

  19. 3D analysis of condylar remodelling and skeletal relapse following bilateral sagittal split advancement osteotomies

    NARCIS (Netherlands)

    Xi, T.; Schreurs, R.; Loon, B. van; Koning, M.J. de; Berge, S.J.; Hoppenreijs, T.J.; Maal, T.J.J.

    2015-01-01

    A major concern in mandibular advancement surgery using bilateral sagittal split osteotomies (BSSO) is potential postoperative relapse. Although the role of postoperative changes in condylar morphology on skeletal relapse was reported in previous studies, no study so far has objectified the precise

  20. Skin movement errors in measurement of sagittal lumbar and hip angles in young and elderly subjects.

    Science.gov (United States)

    Kuo, Yi-Liang; Tully, Elizabeth A; Galea, Mary P

    2008-02-01

    Errors in measurement of sagittal lumbar and hip angles due to skin movement on the pelvis and/or lateral thigh were measured in young (n = 21, age = 18.6 +/- 2.1 years) and older (n = 23, age = 70.9 +/- 6.4 years) age groups. Skin reference markers were attached over specific landmarks of healthy young and elderly subjects, who were videotaped in three static positions of hip flexion using the 2D PEAK Motus video analysis system. Sagittal lumbar and hip angles were calculated from skin reference markers and manually palpated landmarks. The elderly subjects demonstrated greater errors in lumbar angle due to skin movement on the pelvis only in the maximal hip flexion position. The traditional model (ASIS-PSIS-GT-LFE) underestimated sagittal hip angle and the revised model (ASIS-PSIS-2/3Th-1/4Th) provided more accurate measurement of sagittal hip angle throughout the full available range of hip flexion. Skin movement on the pelvis had a small counterbalancing effect on the larger errors from lateral thigh markers (GT-LFE), thereby decreasing hip angle error.

  1. Minimally invasive total knee arthroplasty: comparison of jig-based technique versus computer navigation for clinical and alignment outcome.

    Science.gov (United States)

    Hasegawa, Masahiro; Yoshida, Kakunoshin; Wakabayashi, Hiroki; Sudo, Akihiro

    2011-06-01

    Correct alignment of the leg and positioning of the components are important factors in good long-term outcome of total knee arthroplasty (TKA). Computer-assisted navigation systems were introduced to improve component alignment accuracies. The three main hypotheses of this study were that the navigated compared to jig-based patient will show the following: (1) No difference in clinical outcomes. (2) Better alignment in the frontal and sagittal plane. (3) Better rotational positioning of components. The authors evaluated 100 patients who had minimally invasive TKA using either an image-free computer-assisted navigation system (n=50) or a jig-based technique (n=50). Six months postoperatively, clinical and radiological evaluations were performed using full-length standing anteroposterior and lateral radiographs and CT scans of the knee. Knee Society knee score, function score, and range of motion were comparable in the two groups after surgery. The percentage of patients with a frontal tibiofemoral angle within ±3° of the ideal was significantly higher in the navigated group than in the jig-based group (94% vs. 78%, respectively; P=0.041). No significant differences were found between groups in terms of the frontal and sagittal planes as well as rotational alignment of the femoral or tibial components. Computer-assisted TKA gives a better correction of alignment of the leg compared with jig-based TKA when combined with a minimally invasive surgical approach.

  2. Discriminative Shape Alignment

    DEFF Research Database (Denmark)

    Loog, M.; de Bruijne, M.

    2009-01-01

    , not taking into account that eventually the shapes are to be assigned to two or more different classes. This work introduces a discriminative variation to well-known Procrustes alignment and demonstrates its benefit over this classical method in shape classification tasks. The focus is on two...

  3. Light microscope alignment methods.

    Science.gov (United States)

    Bagnell, Robert

    2014-01-01

    Instructions for proper alignment for each of the most common wide field light microscopy contrast techniques are presented: bright field, polarization, dark field, phase contrast, differential interference contrast, and fluorescence. These are then followed by methods on photomicrography, measurement, and cleaning. An extensive set of Notes provides practical tips for each of these methods.

  4. Advanced aligner orthodontics

    OpenAIRE

    Ojima Kenji

    2017-01-01

    Invisalign initially had limitations which have now been overcome.Advances in the quality of aligner materials, attachments and the introduction of a new force system, have expanded the range of treatment possibilities from severe crowding to more difficult extraction cases, open bite cases, and lower molar distalization cases.

  5. Advanced aligner orthodontics

    Directory of Open Access Journals (Sweden)

    Ojima Kenji

    2017-01-01

    Full Text Available Invisalign initially had limitations which have now been overcome.Advances in the quality of aligner materials, attachments and the introduction of a new force system, have expanded the range of treatment possibilities from severe crowding to more difficult extraction cases, open bite cases, and lower molar distalization cases.

  6. MUON DETECTORS: ALIGNMENT

    CERN Multimedia

    G. Gomez and Y. Pakhotin

    2012-01-01

      A new track-based alignment for the DT chambers is ready for deployment: an offline tag has already been produced which will become part of the 52X Global Tag. This alignment was validated within the muon alignment group both at low and high momentum using a W/Z skim sample. It shows an improved mass resolution for pairs of stand-alone muons, improved curvature resolution at high momentum, and improved DT segment extrapolation residuals. The validation workflow for high-momentum muons used to depend solely on the “split cosmics” method, looking at the curvature difference between muon tracks reconstructed in the upper or lower half of CMS. The validation has now been extended to include energetic muons decaying from heavily boosted Zs: the di-muon invariant mass for global and stand-alone muons is reconstructed, and the invariant mass resolution is compared for different alignments. The main areas of development over the next few months will be preparing a new track-based C...

  7. Aligning Mental Representations

    DEFF Research Database (Denmark)

    Kano Glückstad, Fumiko

    2013-01-01

    This work introduces a framework that implements asymmetric communication theory proposed by Sperber and Wilson [1]. The framework applies a generalization model known as the Bayesian model of generalization (BMG) [2] for aligning knowledge possessed by two communicating parties. The work focuses...

  8. DotAligner

    DEFF Research Database (Denmark)

    Smith, Martin A.; Seemann, Stefan E.; Quek, Xiu Cheng

    2017-01-01

    a computational method, DotAligner, for the unsupervised discovery and classification of homologous RNA structure motifs from a set of sequences of interest. Our approach outperforms comparable algorithms at clustering known RNA structure families, both in speed and accuracy. It identifies clusters of known...... and novel structure motifs from ENCODE immunoprecipitation data for 44 RNA-binding proteins....

  9. Aligning Responsible Business Practices

    DEFF Research Database (Denmark)

    Weller, Angeli E.

    2017-01-01

    This article offers an in-depth case study of a global high tech manufacturer that aligned its ethics and compliance, corporate social responsibility, and sustainability practices. Few large companies organize their responsible business practices this way, despite conceptual relevance and calls...... and managers interested in understanding how responsible business practices may be collectively organized....

  10. Resource Alignment ANADP

    OpenAIRE

    Grindley, Neil; Cramer, Tom; Schrimpf, Sabine; Wilson, Tom

    2014-01-01

    Aligning National Approaches to Digital Preservation: An Action Assembly Biblioteca de Catalunya (National Library of Catalonia) November 18-20, 2013, Barcelona, Spain Auburn University Council on Library and Information Resources (CLIR) Digital Curation Centre (DCC) Digital Preservation Network (DPN) Joint Information Systems Committee (JISC) University of North Texas Virginia Tech Interuniversity Consortium for Political and Social Research (ICPSR) Innovative Inte...

  11. Capacity Alignment ANADP

    OpenAIRE

    Davidson, Joy; Whitehead, Martha; Molloy, Laura; Molinaro, Mary

    2014-01-01

    Aligning National Approaches to Digital Preservation: An Action Assembly Biblioteca de Catalunya (National Library of Catalonia) November 18-20, 2013, Barcelona, Spain Auburn University Council on Library and Information Resources (CLIR) Digital Curation Centre (DCC) Digital Preservation Network (DPN) Joint Information Systems Committee (JISC) University of North Texas Virginia Tech Interuniversity Consortium for Political and Social Research (ICPSR) Innovative Inte...

  12. Fast global sequence alignment technique

    KAUST Repository

    Bonny, Mohamed Talal

    2011-11-01

    Bioinformatics database is growing exponentially in size. Processing these large amount of data may take hours of time even if super computers are used. One of the most important processing tool in Bioinformatics is sequence alignment. We introduce fast alignment algorithm, called \\'Alignment By Scanning\\' (ABS), to provide an approximate alignment of two DNA sequences. We compare our algorithm with the wellknown sequence alignment algorithms, the \\'GAP\\' (which is heuristic) and the \\'Needleman-Wunsch\\' (which is optimal). The proposed algorithm achieves up to 51% enhancement in alignment score when it is compared with the GAP Algorithm. The evaluations are conducted using different lengths of DNA sequences. © 2011 IEEE.

  13. ABS: Sequence alignment by scanning

    KAUST Repository

    Bonny, Mohamed Talal

    2011-08-01

    Sequence alignment is an essential tool in almost any computational biology research. It processes large database sequences and considered to be high consumers of computation time. Heuristic algorithms are used to get approximate but fast results. We introduce fast alignment algorithm, called Alignment By Scanning (ABS), to provide an approximate alignment of two DNA sequences. We compare our algorithm with the well-known alignment algorithms, the FASTA (which is heuristic) and the \\'Needleman-Wunsch\\' (which is optimal). The proposed algorithm achieves up to 76% enhancement in alignment score when it is compared with the FASTA Algorithm. The evaluations are conducted using different lengths of DNA sequences. © 2011 IEEE.

  14. Sagittal synostosis in X-linked hypophosphatemic rickets and related diseases

    Energy Technology Data Exchange (ETDEWEB)

    Currarino, Guido [Texas Scottish Rite Hospital, Department of Radiology, Dallas, TX (United States)

    2007-08-15

    The recent observations of two new cases of X-linked hypophosphatemic rickets associated with premature closure of the sagittal suture prompted a review of similar cases seen in this institution. To review the clinical records and skull radiographs of 28 children with hypophosphatemic rickets in order to investigate the frequency and type of craniosynostosis and other cranial vault changes seen in these conditions and to review the literature for relevant findings. Clinical and imaging records were reviewed on 28 patients with hypophosphatemic rickets, all younger than 18 years. Most patients had X-linked hypophosphatemic rickets and a few had autosomal-dominant hypophosphatemic rickets or were non-familial cases. Of the 28 patients, 13 had sagittal synostosis. Dolichocephaly was present in ten patients. The configuration of the cranial vault in some of these ten patients with dolichocephaly varied somewhat from that seen in nonsyndromic sagittal synostosis. In one patient, a Chiari I malformation was demonstrated by MRI. In another patient with increased intracranial pressure the sagittal suture closure was associated with lambdoidal synostosis. Dolichocephaly was not present in three patients, suggesting that the synostosis started later than in the other patients, probably in the second year of life, a period of slower brain growth than in the first year. The two patients in this group of three showed thickening and sclerosis of the cranial vault of uncertain etiology. There is an increased risk of sagittal synostosis in hypophosphatemic rickets and related diseases in children. The appearance of the cranial vault in this type of synostosis can vary from that seen in nonsyndromic synostosis. In this setting, careful clinical and imaging follow-up is warranted. (orig.)

  15. MUSE alignment onto VLT

    Science.gov (United States)

    Laurent, Florence; Renault, Edgard; Boudon, Didier; Caillier, Patrick; Daguisé, Eric; Dupuy, Christophe; Jarno, Aurélien; Lizon, Jean-Louis; Migniau, Jean-Emmanuel; Nicklas, Harald; Piqueras, Laure

    2014-07-01

    MUSE (Multi Unit Spectroscopic Explorer) is a second generation Very Large Telescope (VLT) integral field spectrograph developed for the European Southern Observatory (ESO). It combines a 1' x 1' field of view sampled at 0.2 arcsec for its Wide Field Mode (WFM) and a 7.5"x7.5" field of view for its Narrow Field Mode (NFM). Both modes will operate with the improved spatial resolution provided by GALACSI (Ground Atmospheric Layer Adaptive Optics for Spectroscopic Imaging), that will use the VLT deformable secondary mirror and 4 Laser Guide Stars (LGS) foreseen in 2015. MUSE operates in the visible wavelength range (0.465-0.93 μm). A consortium of seven institutes is currently commissioning MUSE in the Very Large Telescope for the Preliminary Acceptance in Chile, scheduled for September, 2014. MUSE is composed of several subsystems which are under the responsibility of each institute. The Fore Optics derotates and anamorphoses the image at the focal plane. A Splitting and Relay Optics feed the 24 identical Integral Field Units (IFU), that are mounted within a large monolithic structure. Each IFU incorporates an image slicer, a fully refractive spectrograph with VPH-grating and a detector system connected to a global vacuum and cryogenic system. During 2012 and 2013, all MUSE subsystems were integrated, aligned and tested to the P.I. institute at Lyon. After successful PAE in September 2013, MUSE instrument was shipped to the Very Large Telescope in Chile where that was aligned and tested in ESO integration hall at Paranal. After, MUSE was directly transported, fully aligned and without any optomechanical dismounting, onto VLT telescope where the first light was overcame the 7th of February, 2014. This paper describes the alignment procedure of the whole MUSE instrument with respect to the Very Large Telescope (VLT). It describes how 6 tons could be move with accuracy better than 0.025mm and less than 0.25 arcmin in order to reach alignment requirements. The success

  16. Nuclear reactor alignment plate configuration

    Energy Technology Data Exchange (ETDEWEB)

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  17. Orbit IMU alignment: Error analysis

    Science.gov (United States)

    Corson, R. W.

    1980-01-01

    A comprehensive accuracy analysis of orbit inertial measurement unit (IMU) alignments using the shuttle star trackers was completed and the results are presented. Monte Carlo techniques were used in a computer simulation of the IMU alignment hardware and software systems to: (1) determine the expected Space Transportation System 1 Flight (STS-1) manual mode IMU alignment accuracy; (2) investigate the accuracy of alignments in later shuttle flights when the automatic mode of star acquisition may be used; and (3) verify that an analytical model previously used for estimating the alignment error is a valid model. The analysis results do not differ significantly from expectations. The standard deviation in the IMU alignment error for STS-1 alignments was determined to the 68 arc seconds per axis. This corresponds to a 99.7% probability that the magnitude of the total alignment error is less than 258 arc seconds.

  18. Postural alignment is altered in people with chronic stroke and related to motor and functional performance.

    Science.gov (United States)

    Verheyden, Geert; Ruesen, Carolien; Gorissen, Monique; Brumby, Victoria; Moran, Rachel; Burnett, Malcolm; Ashburn, Ann

    2014-10-01

    Trunk control is impaired after stroke but little is known about how changes in posture relate to other deficits. We examined spinal postural alignment in people with chronic stroke and explored the relationship between postural alignment and clinical measures. Twenty-one subjects with stroke and 22 age-matched healthy comparison subjects participated in this observational, cross-sectional study. Data collection included measurements of thoracic, lumbar, sacral, and overall postural alignment in the sagittal plane in both sitting and standing. Measurements were made in different postures, including: upright, flexed forward, and extended backward. Clinical outcome measures included the Trunk Impairment Scale and its subscales, Fugl-Meyer Scale, Berg Balance Scale, Barthel Index, and Stroke Impact Scale. Significant deviations in postural alignment for participants with stroke compared with comparison subjects were apparent in sacral alignment (P Scale (r = -0.61) and Berg Balance Scale (r = -0.64). Participants with greater anterior pelvic tilt when flexed forward and more overall inclination when flexed forward and extended backward scored better on the Trunk Impairment Scale, its subscales, and Berg Balance Scale (r = -0.6-0.7). People with chronic stroke have altered postural alignment in standing compared with subjects without neurological deficits. Investigating interventions focusing on increasing anterior and posterior pelvic tilt seem warranted.Video Abstract available. See video (Supplemental Digital Content 1, http://links.lww.com/JNPT/A76) for more insights from the authors.

  19. Inflation by Alignment

    CERN Document Server

    Burgess, Cliff

    2015-01-01

    Pseudo-Goldstone bosons (pGBs) can provide technically natural inflatons, as has been comparatively well-explored in the simplest axion examples. Although inflationary success requires trans-Planckian decay constants, f > Mp, several mechanisms have been proposed to obtain this, relying on (mis-)alignments between potential and kinetic energies in multiple-field models. We extend these mechanisms to a broader class of inflationary models, including in particular the exponential potentials that arise for pGB potentials based on noncompact groups (and so which might apply to moduli in an extra-dimensional setting). The resulting potentials provide natural large-field inflationary models and can predict a larger primordial tensor signal than is true for simpler single-field versions of these models. In so doing we provide a unified treatment of several alignment mechanisms, showing how each emerges as a limit of the more general setup.

  20. PLANIMETRIC CHARACTERISTICS OF CORPUS CALLOSUM SAGITTAL PROFILE IN MIDDLE- AND ADVANCED AGED MEN.

    Science.gov (United States)

    Boiagina, O; Kostilenko, Yu

    2017-10-01

    The sagittal profile of the corpus callosum is available for morphometric measurements of conditioned linear distances when elucidating its age-related changes and sexual dimorphism. But in this case, the opportunity to determine the total area of the sagittal profile of the corpus callosum is lost, while being a more full expression of its digital characteristics. We set the goal to establish the differences between planimetric indices of male corpus callosum of the first and second periods of adulthood and the advanced age. The work used 65 brain preparations of men aged 22 to 73 years who died for reasons unrelated to the pathology of the central nervous system. After a two-week fixation in a 10% solution of neutral formalin, the brain was dissected along the longitudinal sagittal fissure into two hemispheres, one of which was used to photograph its medial surface with an overlaid scale ruler. The received standardized photos were used to determine the basic metric parameters and conduct a planimetric study of the sagittal profile of the corpus callosum using the Adobe Photoshop CS6 Extended computer program. The overall evaluation of the results of planimetric analysis of the male corpus callosum sagittal profile we directed attention to the fact that within each age group there is a wide scatter of individual digital values of its area as well as random and irregular nature of their distribution that is completely independent of the intra-group age chronology. Thus, in the first period of adulthood, the minimum value of the area of the corpus callosum sagittal profile is 560 mm2, while the maximum value is 930 mm2 (the average statistical value is 747.5 ± 110.4 mm2). In the second period of adulthood, somewhat lower indicators are indicated; if the minimum value of it is equal to 412 mm2, then the maximum value is 868 mm2 (the average is 684.7 ± 130.0 mm2). In the advanced age, we find them in the range between 441 and 867 mm2 (the average value is 650.2

  1. Measurement and Finite Element Model Validation of Immature Porcine Brain-Skull Displacement during Rapid Sagittal Head Rotations.

    Science.gov (United States)

    Pasquesi, Stephanie A; Margulies, Susan S

    2018-01-01

    Computational models are valuable tools for studying tissue-level mechanisms of traumatic brain injury, but to produce more accurate estimates of tissue deformation, these models must be validated against experimental data. In this study, we present in situ measurements of brain-skull displacement in the neonatal piglet head ( n  = 3) at the sagittal midline during six rapid non-impact rotations (two rotations per specimen) with peak angular velocities averaging 51.7 ± 1.4 rad/s. Marks on the sagittally cut brain and skull/rigid potting surfaces were tracked, and peak values of relative brain-skull displacement were extracted and found to be significantly less than values extracted from a previous axial plane model. In a finite element model of the sagittally transected neonatal porcine head, the brain-skull boundary condition was matched to the measured physical experiment data. Despite smaller sagittal plane displacements at the brain-skull boundary, the corresponding finite element boundary condition optimized for sagittal plane rotations is far less stiff than its axial counterpart, likely due to the prominent role of the boundary geometry in restricting interface movement. Finally, bridging veins were included in the finite element model. Varying the bridging vein mechanical behavior over a previously reported range had no influence on the brain-skull boundary displacements. This direction-specific sagittal plane boundary condition can be employed in finite element models of rapid sagittal head rotations.

  2. Measurement and Finite Element Model Validation of Immature Porcine Brain–Skull Displacement during Rapid Sagittal Head Rotations

    Directory of Open Access Journals (Sweden)

    Stephanie A. Pasquesi

    2018-02-01

    Full Text Available Computational models are valuable tools for studying tissue-level mechanisms of traumatic brain injury, but to produce more accurate estimates of tissue deformation, these models must be validated against experimental data. In this study, we present in situ measurements of brain–skull displacement in the neonatal piglet head (n = 3 at the sagittal midline during six rapid non-impact rotations (two rotations per specimen with peak angular velocities averaging 51.7 ± 1.4 rad/s. Marks on the sagittally cut brain and skull/rigid potting surfaces were tracked, and peak values of relative brain–skull displacement were extracted and found to be significantly less than values extracted from a previous axial plane model. In a finite element model of the sagittally transected neonatal porcine head, the brain–skull boundary condition was matched to the measured physical experiment data. Despite smaller sagittal plane displacements at the brain–skull boundary, the corresponding finite element boundary condition optimized for sagittal plane rotations is far less stiff than its axial counterpart, likely due to the prominent role of the boundary geometry in restricting interface movement. Finally, bridging veins were included in the finite element model. Varying the bridging vein mechanical behavior over a previously reported range had no influence on the brain–skull boundary displacements. This direction-specific sagittal plane boundary condition can be employed in finite element models of rapid sagittal head rotations.

  3. Opportunistic Downlink Interference Alignment

    OpenAIRE

    Yang, Hyun Jong; Shin, Won-Yong; Jung, Bang Chul; Suh, Changho; Paulraj, Arogyaswami

    2013-01-01

    In this paper, we propose an opportunistic downlink interference alignment (ODIA) for interference-limited cellular downlink, which intelligently combines user scheduling and downlink IA techniques. The proposed ODIA not only efficiently reduces the effect of inter-cell interference from other-cell base stations (BSs) but also eliminates intra-cell interference among spatial streams in the same cell. We show that the minimum number of users required to achieve a target degrees-of-freedom (DoF...

  4. Vertebral coplanar alignment technique: a surgical option for correction of adult thoracic idiopathic scoliosis.

    Science.gov (United States)

    He, Shouyu; Bao, Hongda; Zhu, Zezhang; Qiu, Yong; Zhu, Feng; Zhou, Hengcai; Sun, Xu; Wang, Bin

    2016-02-01

    Previous studies have demonstrated vertebral coplanar alignment (VCA) as an effective surgical option for adolescent idiopathic scoliosis (AIS). The purpose of this study is to analyze the outcome of VCA for the surgical correction of adult idiopathic scoliosis (AdIS). 35 AdIS patients (mean age: 24.2 years) undergoing VCA-instrumentation were reviewed. The main thoracic curve and thoracic kyphosis (TK, T5-T12) were evaluated preoperatively, immediate postoperatively, and at the final follow-up (>1 year). All patients were stratified by the TK modifier before surgery: "+" (TK, >40°), "-" (TK, scoliosis with sagittal malalignment.

  5. Seeking the perfect alignment

    CERN Multimedia

    2002-01-01

    The first full-scale tests of the ATLAS Muon Spectrometer are about to begin in Prévessin. The set-up includes several layers of Monitored Drift Tubes Chambers (MDTs) and will allow tests of the performance of the detectors and of their highly accurate alignment system.   Monitored Drift Chambers in Building 887 in Prévessin, where they are just about to be tested. Muon chambers are keeping the ATLAS Muon Spectrometer team quite busy this summer. Now that most people go on holiday, the beam and alignment tests for these chambers are just starting. These chambers will measure with high accuracy the momentum of high-energy muons, and this implies very demanding requirements for their alignment. The MDT chambers consist of drift tubes, which are gas-filled metal tubes, 3 cm in diameter, with wires running down their axes. With high voltage between the wire and the tube wall, the ionisation due to traversing muons is detected as electrical pulses. With careful timing of the pulses, the position of the muon t...

  6. Alignment at the ESRF

    International Nuclear Information System (INIS)

    Martin, D.; Levet, N.; Gatta, G.

    1999-01-01

    The ESRF Survey and Alignment group is responsible for the installation, control and periodic realignment of the accelerators and experiments which produce high quality x-rays used by scientists from Europe and around the world. Alignment tolerances are typically less than one millimetre and often in the order of several micrometers. The group is composed of one engineer, five highly trained survey technicians, one electronic and one computer technician. This team is fortified during peak periods by technicians from an external survey company. First an overview and comparative study of the main large-scale survey instrumentation and methods used by the group is made. Secondly a discussion of long term deformation on the ESRF site is presented. This is followed by presentation of the methods used in the realignment of the various machines. Two important aspects of our work, beamline and front-end alignment, and the so-called machine exotic devices are briefly discussed. Finally, the ESRF calibration bench is presented. (authors)

  7. Correction of sagittal plane deformity and predictive factors for a favourable radiological outcome following multilevel posterior lumbar interbody fusion for mild degenerative scoliosis.

    Science.gov (United States)

    Sabou, Silviu; Tseng, Tzu-Heng Jason; Stephenson, John; Siddique, Irfan; Verma, Rajat; Mohammad, Saeed

    2016-08-01

    Limited data is available in the literature on the radiographic results of multilevel posterior lumbar interbody fusion (MPLIF) in the treatment of degenerative scoliosis. The objective of our study was to evaluate the segmental and global correction achieved with MPLIF in the treatment of degenerative scoliosis. Between 2009 and 2014, 42 patients underwent correction of degenerative scoliosis with MPLIF. Several radiological parameters were measured pre- and post-operatively by two independent observers. A statistical analysis was performed to assess the inter-observer reliability of the measurements and to determine the degree of segmental correction achieved at each intervertebral disc. Using sagittal vertical axis (SVA) less than 47 mm; lumbar lordosis (LL) within 11° of pelvic incidence (PI); and pelvic tilt (PT) no more than 22° as radiological criteria for procedural acceptability, we determined predictive factors for a favourable radiological outcome. Forty-two patients (34 female) were included in our study. The average amount of correction per segment was 6.2°. The overall correction achieved with MPLIF was 16.6°. Twenty-six of the 42 patients (61.9 %) had post-operative SVA values less than 47 mm. Nineteen of the 42 patients (45.2 %) had average post-operative LL within 11° of the PI. Sixteen of the 42 patients (38.1 %) had PT less than 22°. Younger age, female gender and a low pre-operative PT were significantly associated with the attainment of a satisfactory sagittal alignment. Our results demonstrate that a satisfactory correction can be achieved in degenerative scoliosis with MPLIF. In addition, our results show that it is significantly more likely to achieve a satisfactory radiological outcome in younger, female patients with low pre-operative PT.

  8. The Specific Sagittal Magnetic Resonance Imaging of Intradural Extra-Arachnoid Lumbar Disc Herniation

    Directory of Open Access Journals (Sweden)

    Tatsuro Sasaji

    2012-01-01

    Full Text Available Intradural extra-arachnoid lumbar disc herniation is a rare disease. Few MRI findings have been reported. We experienced an intradural extra-arachnoid lumbar disc herniation. We reviewed the preoperative MRI findings. Lumbar spine T2-weighted sagittal MRI showed that one line of the ventral dura was divided into two by a disc herniation. We speculated that the two lines comprised the dura and arachnoid and that a disc herniation existed between them. We believe that division of the ventral dural line on T2-weighted sagittal images is a characteristic finding of intradural extra-arachnoid lumbar disc herniation. The division of ventral dural line seemed to be a “Y,” and, thus, we called it the “Y sign.” The “Y sign” may be useful for diagnosing intradural extra-arachnoid lumbar disc herniation.

  9. The Specific Sagittal Magnetic Resonance Imaging of Intradural Extra-Arachnoid Lumbar Disc Herniation

    Science.gov (United States)

    Sasaji, Tatsuro; Horaguchi, Kiyoshi; Yamada, Noboru; Iwai, Kazuo

    2012-01-01

    Intradural extra-arachnoid lumbar disc herniation is a rare disease. Few MRI findings have been reported. We experienced an intradural extra-arachnoid lumbar disc herniation. We reviewed the preoperative MRI findings. Lumbar spine T2-weighted sagittal MRI showed that one line of the ventral dura was divided into two by a disc herniation. We speculated that the two lines comprised the dura and arachnoid and that a disc herniation existed between them. We believe that division of the ventral dural line on T2-weighted sagittal images is a characteristic finding of intradural extra-arachnoid lumbar disc herniation. The division of ventral dural line seemed to be a “Y,” and, thus, we called it the “Y sign.” The “Y sign” may be useful for diagnosing intradural extra-arachnoid lumbar disc herniation. PMID:22431932

  10. Influence of implant rod curvature on sagittal correction of scoliosis deformity

    DEFF Research Database (Denmark)

    Salmingo, Remel A.; Tadano, Shigeru; Abe, Yuichiro

    2014-01-01

    scoliosis patients underwent surgery. Average age at the time of operation was 14 years. OUTCOME MEASURES: The preoperative and postoperative implant rod angle of curvature expressed in degrees was obtained for each patient. METHODS: Two implant rods were attached to the concave and convex side...... of curvature between the implant rod extreme ends was measured before implantation and after surgery. The sagittal curvature between the corresponding spinal levels of healthy adolescents obtained by previous studies was compared with the implant rod angle of curvature to evaluate the sagittal curve correction...... significantly deformed after surgery. The average degree of rod deformation Dq at the concave and convex sides was 15.8 and 1.6, respectively. The average preoperative and postoperative implant rod angle of curvature at the concave side was 33.6 and 17.8, respectively. The average preoperative and postoperative...

  11. Craniofacial characteristics in the sagittal dimension: A cephalometric study in Lebanese young adults.

    Science.gov (United States)

    Daraze, Antoine; Delatte, Myriam; Bou Saba, Sami; Majzoub, Zeina

    2017-03-01

    The purpose of this study was to assess the sagittal cephalometric characteristics of young adult Lebanese individuals and assess gender-related differences. Conventional lateral cephalograms were obtained from 117 subjects. Eight linear/angular measurements combining sagittal parameters selected form McNamara and Steiner analyses were recorded. Paired t-test was applied to evaluate differences between genders and skeletal classes. Males showed significantly greater maxillary and mandibular length than females. ANB was larger in females with no significant differences in SNA values indicating that Lebanese females tend to have a more convex profile than their male counterparts. Subjects with skeletal Class III tended to have a retrognathic maxilla rather than a prognathic mandible. Sexual dimorphism is evident in young Lebanese adults relative to linear skeletal dimensions regardless of the skeletal class. Skeletal determinants of Class III malocclusions may be different from those of other population groups. Copyright © 2016 CEO. Published by Elsevier Masson SAS. All rights reserved.

  12. Sagittal synostosis: II. Cranial morphology and growth after the modified pi-plasty

    DEFF Research Database (Denmark)

    Guimaraes-Ferreira, J.; Gewalli, F.; David, L.

    2006-01-01

    The aim of this study was to characterise the postoperative cranial growth and morphology after a modified pi-plasty for sagittal synostosis. The shape of the skull of 82 patients with isolated premature synostosis of the sagittal suture ( SS group) operated on with a modified pi-plasty was studied...... developed by Kreiborg, which included the digitisation of 89 landmarks of the calvaria, cranial base, and orbit ( 43 in the lateral and 46 in the frontal projections), the production of mean shape plots for each group, and the intergroup comparison of a series of 78 variables ( linear distance between...... selected landmarks, and angles defined by groups of three landmarks). Paired and unpaired t tests were used to assess the differences between the variables studied. These were accepted as significant for values of p...

  13. A Review Of Referral Patterns For Sagittal Synostosis In Ireland: 2008-2013

    LENUS (Irish Health Repository)

    Berney, M J

    2018-01-01

    Sagittal synostosis (SS) is the commonest form of craniosynostosis. Children with sagittal synostosis in Ireland are treated in the National Paediatric Craniofacial Centre (NPCC) in Temple Street Children’s University Hospital. This retrospective study analysed the correlation between referral patterns to the unit and age at operation. The notes of 81 patients referred over a 5 year period (April 2008 – April 2013) to the NPCC with non-syndromic SS were reviewed and demographics and referral information were recorded. Of 81 patients reviewed, 60 (74%) were referred before 6 months of age, while 21 (26%) had late referrals. Neonatologists referred 100% of infants before 6 months, paediatricians referred 71%, and GPs 64%. Later referral was associated with a more complex referral pathway, including multiple-steps of referral and unnecessary investigations. Improved clinician knowledge and emphasis on the importance of early referral may lead to a reduction in late referrals.

  14. Sagittal crystal focusing of undulator radiation with high heat load inclined crystals

    International Nuclear Information System (INIS)

    Ice, G.E.; Sparks, C.J.

    1992-01-01

    Sagittal focusing of undulator radiation is shown to be compatible with the proposed inclined double-crystal monochromator geometry for heat load reduction. The focusing aberrations are found to be negligible for typical undulator-beam divergences over a range of magnifications from 1:2 to 6:1 and energies from 3 to 40 keV. The inclined geometry reduces the required signal sagittal curvature of the focusing crystal compared to focusing with conventional symmetric crystals; hence, focusing is possible at higher X-ray energies and with less anticlastic bending. In addition, anticlastic stiffening ribs project a smaller footprint to the beam so that the achievable focal spot size is potentially better than with conventional symmetrically cut crystals. 16 refs

  15. The CMS Muon System Alignment

    CERN Document Server

    Martinez Ruiz-Del-Arbol, P

    2009-01-01

    The alignment of the muon system of CMS is performed using different techniques: photogrammetry measurements, optical alignment and alignment with tracks. For track-based alignment, several methods are employed, ranging from a hit and impact point (HIP) algorithm and a procedure exploiting chamber overlaps to a global fit method based on the Millepede approach. For start-up alignment as long as available integrated luminosity is still significantly limiting the size of the muon sample from collisions, cosmic muon and beam halo signatures play a very strong role. During the last commissioning runs in 2008 the first aligned geometries have been produced and validated with data. The CMS offline computing infrastructure has been used in order to perform improved reconstructions. We present the computational aspects related to the calculation of alignment constants at the CERN Analysis Facility (CAF), the production and population of databases and the validation and performance in the official reconstruction. Also...

  16. Alignment of suprathermally rotating grains

    Science.gov (United States)

    Lazarian, A.

    1995-12-01

    It is shown that mechanical alignment can be efficient for suprathermally rotating grains, provided that they drift with supersonic velocities. Such a drift should be widely spread due to both Alfvenic waves and ambipolar diffusion. Moreover, if suprathermal rotation is caused by grain interaction with a radiative flux, it is shown that mechanical alignment may be present even in the absence of supersonic drift. This means that the range of applicability of mechanical alignment is wider than generally accepted and that it can rival the paramagnetic one. We also study the latter mechanism and re-examine the interplay between poisoning of active sites and desorption of molecules blocking the access to the active sites of H_2 formation, in order to explain the observed poor alignment of small grains and good alignment of large grains. To obtain a more comprehensive picture of alignment, we briefly discuss the alignment by radiation fluxes and by grain magnetic moments.

  17. Clear aligners in orthodontic treatment.

    Science.gov (United States)

    Weir, T

    2017-03-01

    Since the introduction of the Tooth Positioner (TP Orthodontics) in 1944, removable appliances analogous to clear aligners have been employed for mild to moderate orthodontic tooth movements. Clear aligner therapy has been a part of orthodontic practice for decades, but has, particularly since the introduction of Invisalign appliances (Align Technology) in 1998, become an increasingly common addition to the orthodontic armamentarium. An internet search reveals at least 27 different clear aligner products currently on offer for orthodontic treatment. The present paper will highlight the increasing popularity of clear aligner appliances, as well as the clinical scope and the limitations of aligner therapy in general. Further, the paper will outline the differences between the various types of clear aligner products currently available. © 2017 Australian Dental Association.

  18. Is Postoperative Intensive Care Unit Care Necessary following Cranial Vault Remodeling for Sagittal Synostosis?

    Science.gov (United States)

    Wolfswinkel, Erik M; Howell, Lori K; Fahradyan, Artur; Azadgoli, Beina; McComb, J Gordon; Urata, Mark M

    2017-12-01

    Of U.S. craniofacial and neurosurgeons, 94 percent routinely admit patients to the intensive care unit following cranial vault remodeling for correction of sagittal synostosis. This study aims to examine the outcomes and cost of direct ward admission following primary cranial vault remodeling for sagittal synostosis. An institutional review board-approved retrospective review was undertaken of the records of all patients who underwent primary cranial vault remodeling for isolated sagittal craniosynostosis from 2009 to 2015 at a single pediatric hospital. Patient demographics, perioperative course, and outcomes were recorded. One hundred ten patients met inclusion criteria with absence of other major medical problems. Average age at operation was 6.7 months, with a mean follow-up of 19.8 months. Ninety-eight patients (89 percent) were admitted to a general ward for postoperative care, whereas the remaining 12 (11 percent) were admitted to the intensive care unit for preoperative or perioperative concerns. Among ward-admitted patients, there were four (3.6 percent) minor complications; however, there were no major adverse events, with none necessitating intensive care unit transfers from the ward and no mortalities. Average hospital stay was 3.7 days. The institution's financial difference in cost of intensive care unit stay versus ward bed was $5520 on average per bed per day. Omitting just one intensive care unit postoperative day stay for this patient cohort would reduce projected health care costs by a total of $540,960 for the study period. Despite the common practice of postoperative admission to the intensive care unit following cranial vault remodeling for sagittal craniosynostosis, the authors suggest that postoperative care be considered on an individual basis, with only a small percentage requiring a higher level of care. Therapeutic, III.

  19. Evaluation of the Sagittal Saw Blade as an Intraoperative Fomite During Diabetic Foot Surgery.

    Science.gov (United States)

    Creech, Corine L; Malan, Jared R; Meyr, Andrew J

    2015-08-01

    Surgical site infection is a major potential complication of all operative interventions, and the diabetic foot is particularly at risk for bacterial recontamination and infectious sequelae. The objective of this study was to identify whether the sagittal saw blade used during partial foot amputations and diabetic foot debridements carries the potential to serve as a bacterial fomite. We physically cultured the sagittal saw blade during 20 foot debridements involving the resection of bone in patients diagnosed with a diabetic foot infection. The culture was taken after the initial debridement and during the irrigation phase of the procedure. We observed 16 positive routine intraoperative culture results, with positive saw blade culture results in 15 (93.8%; 15/16) of these cases. In 14 (93.3%; 14/15) of these cases, the saw blade culture grew at least one of the same bacteria as our other routine intraoperative cultures. We observed 4 negative routine intraoperative culture results, with negative saw blade culture results in 3 (75.0%; 3/4) of these cases. This results in agreement between routine intraoperative cultures and saw blade culture of 85.0% (17/20). The results of this investigation demonstrate that the sagittal saw blade used for osseous resection during diabetic foot debridements and partial foot amputations carries the potential for intraoperative bacterial transmission. We recommend changing at least the sagittal saw blade if more bone is resected following irrigation, particularly if it is used to obtain a "clean margin" for microbiological or histological examination. Therapeutic, Level IV: Case series. © 2014 The Author(s).

  20. The Specific Sagittal Magnetic Resonance Imaging of Intradural Extra-Arachnoid Lumbar Disc Herniation

    OpenAIRE

    Sasaji, Tatsuro; Horaguchi, Kiyoshi; Yamada, Noboru; Iwai, Kazuo

    2012-01-01

    Intradural extra-arachnoid lumbar disc herniation is a rare disease. Few MRI findings have been reported. We experienced an intradural extra-arachnoid lumbar disc herniation. We reviewed the preoperative MRI findings. Lumbar spine T2-weighted sagittal MRI showed that one line of the ventral dura was divided into two by a disc herniation. We speculated that the two lines comprised the dura and arachnoid and that a disc herniation existed between them. We believe that division of the ventral du...

  1. 3 Dimensional Plate in Management of Sagittal Palatal Fracture: A Novel Technique.

    Science.gov (United States)

    Rai, Anshul

    2017-12-01

    The palatal fracture is rare. There are varieties of techniques mentioned in the literature for fixation of palatal fracture. The management with Kirschner wire fixation, maxillary arch stabilization with the arch bars, trans-palatal, intra osseous, inter-molar, figure of eight wiring were technique sensitive and having poor patient compliance. We recommended the use of isolated 3 dimensional plate for fixation of sagittal palatal fracture.

  2. Sagittal fractures of the third carpal bone in horses: 12 cases (1977-1985)

    International Nuclear Information System (INIS)

    Fischer, A.T. Jr.; Stover, S.M.

    1987-01-01

    Third carpal sagittal fractures were found to be related to racing injuries in 10 of 12 horses. These fractures occurred most commonly on the medial aspect of the bone. A dorsoproximal-dorsodistal view of the carpus was required to visualize the fracture in all cases. Healing of the fracture required periods of rest of up to one year. Conservative management of these fractures resulted in return to function in 7 of 12 horses

  3. Correlation of Dental and Skeletal Malocclusions in Sagittal Plane among Saudi Orthodontic Patients.

    Science.gov (United States)

    Al-Hamlan, Nasir; Al-Eissa, Balsam; Al-Hiyasat, Ahmad S; Albalawi, Farraj S; Ahmed, Anwar E

    2015-05-01

    Whether or not the dental relationship correlates with skeletal relationship in the sagittal plane is an area of interest for orthodontic diagnosis and treatment planning. Thus, the aim of this study was to investigate the correlation of the dental malocclusion and the skeletal malocclusion in the sagittal plane among Saudi orthodontic patients. Orthodontic dental casts and cephalometric radiographs of 124 patients were investigated and analyzed. The dental casts were classified in relation to the molar relationship according to Angle's classification and to the incisal relationship according to the British Standards Institution (BSI) classification. The sagittal relation in the cephalometric radiographs was analyzed according to ANB angle and WITS appraisal. The results show that the incisal relation had a very high significant association with WITS appraisal (p = 0.0045), whereas with ANB, the association was marginally significant (p =0.0528). No significant associations were found with molar relation neither at ANB (p = 0.2075) nor at the WITS (p = 0.4794) appraisal. Significant positive correlations between ANB and WITS appraisal were found at the three incisal classification classes (class I, r = 0.73; class II, r = 0.64; class III, r = 0.75) and no significant correlation was observed in all classes with the Angle's (molar) classification. The incisal classification had a significant association with WITS appraisal, whereas with ANB the association was marginally significant. No correlation was found between Angle's (molar) classification and ANB or WITS appraisal. The incisal relation could be considered as a good indicator of the skeletal malocclusion in the sagittal plane in the orthodontic practice.

  4. Sagittal changes in lower incisors by the use of lingual arch

    OpenAIRE

    Letti,Helen Carolina Becker; Rizzatto,Susana Maria Deon; Menezes,Luciane Macedo de; Reale,Chalana Sangalli; Lima,Eduardo Martinelli de; Martinelli,Fernando Lima

    2013-01-01

    OBJECTIVE: The objective of this study was to evaluate a sagittal variation on the lower incisors with the use of the lingual arch on the transition from mixed to permanent dentition. METHODS: The sample was constituted of 44 Caucasian patients (26 girls and 18 boys), divided in two groups: CG, control group, monitoring the lower arch space with no orthodontic/orthopedic treatment during the rated period (n = 14); EG, experimental group, presenting anterior inferior mild crowding and installa...

  5. Current concepts on the sagittal balance and classification of spondylolysis and spondylolisthesis ? ??

    OpenAIRE

    Tebet, Marcos Antonio

    2014-01-01

    Treatment of spondylolysis and spondylolisthesis remains a challenge for orthopaedic surgeons, neurosurgeons and paediatrics. In spondylolisthesis, it has been clearly demonstrated over the past decade that spino-pelvic morphology is abnormal and that it can be associated to an abnormal sacro-pelvic orientation as well as to a disturbed global sagittal balance of spine. This article presents the SDSG (Spinal Deformity Study Group) classification of lumbosacral spondylolisthesis. The proper tr...

  6. Sagittal abdominal diameter shows better correlation with cardiovascular risk factors than waist circumference and BMI

    OpenAIRE

    de Souza, Natalia Cavalheri; de Oliveira, Erick Prado

    2013-01-01

    Background Obesity (abdominal adiposity) is a risk factor for cardiovascular diseases and the most used methods to measure the adiposity are body mass index (BMI), waist circumference (WC), and sagittal abdominal diameter (SAD). Objective To correlate BMI, WC, and SAD with biochemical parameters and blood pressure in adults. Methods A non-experimental exploratory/descriptive and cross sectional study was developed and it was assessed 133 subjects (59 men and 74 women) aging between 18 and 87?...

  7. The effect of neurocranial surgery on basicranial morphology in isolated sagittal craniosynostosis.

    Science.gov (United States)

    DeLeon, V B; Zumpano, M P; Richtsmeier, J T

    2001-03-01

    Isolated sagittal craniosynostosis produces a scaphocephalic neurocranium associated with abnormal basicranial morphology, providing additional evidence of the developmental relationship of the neurocranium and basicranium. Corrective surgical procedures vary, but the immediate impact of the surgical procedure is restricted to the neurocranium. This study addresses the secondary effects of neurocranial surgery on the cranial base. Three-dimensional (3-D) computed tomography (CT) scans were obtained for preoperative (n = 25) and postoperative (n = 12) patients with isolated sagittal synostosis. Landmark data from 14 landmarks on and around the cranial base were collected from 3-D CT reconstructions and analyzed using Euclidean distance matrix analysis. Subsamples of age-matched patients were used to identify basicranial differences in pre- and postoperative patients and to compare postoperative growth patterns identified in longitudinal data with preoperative growth patterns characterized in cross-sectional data. Statistically significant differences (p asterion, and left asterion are similar in preoperative and postoperative patients. However, the position of these landmarks relative to the cranial base is different in the two groups, being positioned relatively more anteriorly in postoperative patients. In addition, we found that the cranial base angle, on average, neither increases nor decreases in the first postoperative year. These morphological differences are associated with divergent growth trajectories in the operated and unoperated cranial base. Regardless of specific procedure, neurocranial surgery in sagittal synostosis patients affects growth patterns of the cranial base. The lack of change in the postoperative cranial base angle suggests that neurocranial surgery alleviates the occipital rotation and decreased cranial base angle described in the sagittal synostosis basicranium.

  8. Determination of craniofacial relation among the subethnic Indian population: A modified approach - (Sagittal relation

    Directory of Open Access Journals (Sweden)

    A Sumathi Felicita

    2012-01-01

    Full Text Available Aim : To measure the linear cephalometric dimensions of anterior and posterior segments of the craniofacial complex sagittally, to establish ratios between different linear dimensions of sagittal segments and check for dimensional balance among the various segments in subjects with normal occlusion, pleasing profile and facial harmony. Setting and Sample Population : Department of Orthodontics, Saveetha University. Lateral cephalograms of 120 subjects of both sexes in the age group of 17-28 years with normal occlusion belonging to Chennai, India Materials and Methods : Linear dimensions of anterior and posterior segments of the craniofacial complex were measured sagittally with the posterior maxillary plane as a key reference plane. Ratios were established between the various parameters in the anterior and posterior region. Results : A ratio of 1:1 was found to exist between the individual and aggregate sagittal segments of the craniofacial complex in both sexes. There was a statistically significant sexual dimorphism in the aggregate lengths(P=0.028,P=0.005.However, the ratio between the anterior cranial floor and effective maxillary length was 2:3 and 5:8 and that between anterior cranial floor to effective mandibular length was 5:8 and 3:5 in females and males respectively. The difference in the above values was not statistically significant. Conclusion : A dimensional balance was found to exist between the maxilla and mandible both at the dentoalveolar and skeletal level with a ratio of 1:1. There was also a dimensional balance between the posterior cranial floor and ramus width. However, there was no architectural balance between the anterior cranial floor and maxilla and mandible.

  9. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Science.gov (United States)

    Yang, Yang; Fang, Ying; Zhang, Xini; He, Junliang; Fu, Weijie

    2017-12-01

    The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively) performed a weight-bearing dorsiflexion (WB-DF) maneuver, drop jumps (DJs), and lay-up jumps (LJs). Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041) was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028) and power (p = 0.022) were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion-extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane.

  10. [Analysis of variation of sagittal position of the jaw bones in skeletal Class III malocclusion].

    Science.gov (United States)

    Stojanović, Zdenka; Nikolić, Predrag; Nikodijević, Angelina; Milić, Jasmina; Duka, Milos

    2012-12-01

    Skeletal Class III malocclusion is a discrepancy in the sagittal jaw relationship, due to imbalances in their development and/or position, resulting in the dominant appearance of the lower jaw in facial profile. The aim of this study was to determine variations in the sagittal position of the jaw bones to the cranial base in subjects with skeletal Class III, for the earliest possible diagnosis of malocclusion. Fifty children and as many adults with skeletal Class III, both sexes, were examined and selected, based on the findings of sagittal interjaw relationship (ANB) children aged 6-12 years, and another group, of adults aged 18-26 years. We measured the angles of maxillary prognathism (SNA), mandibular prognathism (SNB) and ANB. Based on these results, within the respective groups subclassification into the subgroups was done, among which a significant difference measured values was evaluated. In both groups a significant correlation of the determined values was evaluated. An average SNA angle ranged 77.36 +/- 3.58 in children and 77.32 +/- 4.88 in adults, while an average SNB angle was 79.46 +/- 3.91 in the group of children and 81.12 +/- 3.76 in adults. An average ANB angle was -2.10 +/- 2.07 in children, and -4.00 +/- 2.34 in adults. In both groups, a significant correlation between the measured values and a significant difference in the values of all the measured parameters were found between patients from different subgroups (p children and adults. Sagittal position of the lower jaw in most of the adults was prognathic, while mandible prognathism in the children was less present.

  11. Correlation between sagittal plane changes and adjacent segment degeneration following lumbar spine fusion

    OpenAIRE

    Kumar, Malhar; Baklanov, Andrei; Chopin, Daniel

    2001-01-01

    Adjacent segment degeneration following lumbar spine fusion remains a widely acknowledged problem, but there is insufficient knowledge regarding the factors that contribute to its occurrence. The aim of this study is to analyse the relationship between abnormal sagittal plane configuration of the lumbar spine and the development of adjacent segment degeneration. Eighty-three consecutive patients who underwent lumbar fusion for degenerative disc disease were reviewed retrospectively. Patients ...

  12. Demonstration of superior sagittal sinus thrombosis by indium-111 platelet scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Bridgers, S.L.; Strauss, E.; Smith, E.O.; Reed, D.; Ezekowitz, M.D.

    1986-10-01

    Superior sagittal sinus thrombosis, documented by cerebral angiography, was demonstrated by indium-111 platelet scintigraphy in a 40-year-old man presenting with seizures and intracerebral hematoma. Early scintigraphy demonstrated focal increased indium-111 activity at the two ends of the thrombus, while later scintigraphy showed diffuse increased activity in the area of the sinus. This initial experience suggests that platelet scintigraphy may provide unique information regarding the natural history of intracranial venous thrombosis.

  13. Comparison of Two Forced Alignment Systems for Aligning Bribri Speech

    Directory of Open Access Journals (Sweden)

    Rolando Coto-Solano

    2017-04-01

    Full Text Available Forced alignment provides drastic savings in time when aligning speech recordings and is particularly useful for the study of Indigenous languages, which are severely under-resourced in corpora and models. Here we compare two forced alignment systems, FAVE-align and EasyAlign, to determine which one provides more precision when processing running speech in the Chibchan language Bribri. We aligned a segment of a story narrated in Bribri and compared the errors in finding the center of the words and the edges of phonemes when compared with the manual correction. FAVE-align showed better performance: It has an error of 7% compared to 24% with EasyAlign when finding the center of words, and errors of 22~24 ms when finding the edges of phonemes, compared to errors of 86~130 ms with EasyAlign. In addition to this, EasyAlign failed to detect 7% of phonemes, while also inserting 58 spurious phones into the transcription. Future research includes verifying these results for other genres and other Chibchan languages. Finally, these results provide additional evidence for the applicability of natural language processing methods to Chibchan languages and point to future work such as the construction of corpora and the training of automated speech recognition systems.

  14. [A biomechanic study on the relapse after sagittal split and oblique osteotomy of Ramus].

    Science.gov (United States)

    Li, Wei; Song, Yufeng; Wang, Dazhang

    2004-02-01

    The relapse after orthognathic surgery was frequently reported in recent years. But up to now researches concerning bio-mechanic mechanism of relapse are rare. The purpose of this study, by imitating the operation on monkeys, was to examine the biomechanical properties and histological characteristics after operation in order to investigate the mechanism of the relapse after orthognathic surgery. 20 rhesus monkeys divided into two groups were subjected to bilateral sagittal split and oblique osteotomy, respectively. The broken strength, stress and strain of the operated sites were examined with the use of biomechanical methods, and the healing scab was observed using histological method and SEM at 3, 6, 12, 24 weeks after operation. The results obtained demonstrated that bone healing and biomechanical properties reached certain level after 6 to 12 weeks' recovery in both operation groups; the biomechanical properties and histological characteristics recovered faster in sagittal split group than in oblique osteotomy group. Histological examination also demonstrated similar results. From the data above it is suggested that the higher relapse rate in sagittal split may more closely related to the mechanical effect different from the scab healing, although 8 weeks' fixation may meet the requirement of clinical treatment, accessory fixation method should be adopted after the removal of inter-maxilla fixation.

  15. The Role of Proprioception in the Sagittal Setting of Anticipatory Postural Adjustments During Gait Initiation

    Directory of Open Access Journals (Sweden)

    Pereira Marcelo P.

    2015-12-01

    Full Text Available Purpose. Previous studies have studied the role of proprioception on the setting of anticipatory postural adjustments (APA during gait initiation. However, these studies did not investigate the role of proprioception in the sagittal APA setting. We aimed to investigate the role of proprioception manipulation to induce APA sagittal adaptations on gait initiation. Methods. Fourteen healthy adults performed gait initiation without, and with, vibration applied before movement onset, and during movement. In addition, the effects of two different vibration frequencies (80 and 120Hz were tested. Vibration was applied bilaterally on the tibialis anterior, rectus femoris and trapezius superior. The first step characteristics, ground reaction forces and CoP behaviour were assessed. Results. Vibration improved gait initiation performance regardless of the moment it was applied. CoP velocity during the initial phase of APA was increased by vibration only when it was applied before movement. When vibration was applied to disturb the movement, no effects on the CoP behaviour were observed. Manipulation of vibration frequency had no effects. Conclusions. Rather than proprioception manipulation, the results suggest that post-vibratory effects and attentional mechanisms were responsible for our results. Taken together, the results show that sagittal APA setting is robust to proprioception manipulation.

  16. Differences of Sagittal Lumbosacral Parameters between Patients with Lumbar Spondylolysis and Normal Adults.

    Science.gov (United States)

    Yin, Jin; Peng, Bao-Gan; Li, Yong-Chao; Zhang, Nai-Yang; Yang, Liang; Li, Duan-Ming

    2016-05-20

    Recent studies have suggested an association between elevated pelvic incidence (PI) and the development of lumbar spondylolysis. However, there is still lack of investigation for Han Chinese people concerning the normal range of spinopelvic parameters and relationship between abnormal sagittal parameters and lumbar diseases. The objective of the study was to investigate sagittal lumbosacral parameters of adult lumbar spondylolysis patients in Han Chinese population. A total of 52 adult patients with symptomatic lumbar spondylolysis treated in the General Hospital of Armed Police Force (Beijing, China) were identified as the spondylolysis group. All the 52 patients were divided into two subgroups, Subgroup A: 36 patients with simple lumbar spondylolysis, and Subgroup B: 16 patients with lumbar spondylolysis accompanying with mild lumbar spondylolisthesis (slip percentage spondylolysis group and the control group with independent-sample t- test. There were no statistically significant differences of all seven sagittal lumbosacral parameters between Subgroup A and Subgroup B. PI, PT, SS, and LL were higher (P spondylolysis group than those in the control group, but STA was lower (P spondylolysis group. Current study results suggest that increased PI and decreased STA may play important roles in the pathology of lumbar spondylolysis in Han Chinese population.

  17. WAVELET ANALYSIS AND NEURAL NETWORK CLASSIFIERS TO DETECT MID-SAGITTAL SECTIONS FOR NUCHAL TRANSLUCENCY MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Giuseppa Sciortino

    2016-04-01

    Full Text Available We propose a methodology to support the physician in the automatic identification of mid-sagittal sections of the fetus in ultrasound videos acquired during the first trimester of pregnancy. A good mid-sagittal section is a key requirement to make the correct measurement of nuchal translucency which is one of the main marker for screening of chromosomal defects such as trisomy 13, 18 and 21. NT measurement is beyond the scope of this article. The proposed methodology is mainly based on wavelet analysis and neural network classifiers to detect the jawbone and on radial symmetry analysis to detect the choroid plexus. Those steps allow to identify the frames which represent correct mid-sagittal sections to be processed. The performance of the proposed methodology was analyzed on 3000 random frames uniformly extracted from 10 real clinical ultrasound videos. With respect to a ground-truth provided by an expert physician, we obtained a true positive, a true negative and a balanced accuracy equal to 87.26%, 94.98% and 91.12% respectively.

  18. Pareto optimal pairwise sequence alignment.

    Science.gov (United States)

    DeRonne, Kevin W; Karypis, George

    2013-01-01

    Sequence alignment using evolutionary profiles is a commonly employed tool when investigating a protein. Many profile-profile scoring functions have been developed for use in such alignments, but there has not yet been a comprehensive study of Pareto optimal pairwise alignments for combining multiple such functions. We show that the problem of generating Pareto optimal pairwise alignments has an optimal substructure property, and develop an efficient algorithm for generating Pareto optimal frontiers of pairwise alignments. All possible sets of two, three, and four profile scoring functions are used from a pool of 11 functions and applied to 588 pairs of proteins in the ce_ref data set. The performance of the best objective combinations on ce_ref is also evaluated on an independent set of 913 protein pairs extracted from the BAliBASE RV11 data set. Our dynamic-programming-based heuristic approach produces approximated Pareto optimal frontiers of pairwise alignments that contain comparable alignments to those on the exact frontier, but on average in less than 1/58th the time in the case of four objectives. Our results show that the Pareto frontiers contain alignments whose quality is better than the alignments obtained by single objectives. However, the task of identifying a single high-quality alignment among those in the Pareto frontier remains challenging.

  19. Analysis of variation of sagittal position of the jaw bones in skeletal class III malocclusion

    Directory of Open Access Journals (Sweden)

    Stojanović Zdenka

    2012-01-01

    Full Text Available Background/Aim. Skeletal Class III malocclusion is a discrepancy in the sagittal jaw relationship, due to imbalances in their development and/or position, resulting in the dominant appearance of the lower jaw in facial profile. The aim of this study was to determine variations in the sagittal position of the jaw bones to the cranial base in subjects with skeletal Class III, for the earliest possible diagnosis of malocclusion. Methods. Fifty children and as many adults with skeletal Class III, both sexes, were examined and selected, based on the findings of sagittal interjaw relationship (ANB ≤ 0° from the cephalometric analysis of tele-x-ray profile head shots. The subjects were grouped according to age. The first group consisted of children aged 6-12 years, and another group, of adults aged 18-26 years. We measured the angles of maxillary prognathism (SNA, mandibular prognathism (SNB and ANB. Based on these results, within the respective groups subclassification into the subgroups was done, among which a significant difference measured values was evaluated. In both groups a significant correlation of the determined values was evaluated. Results. An average SNA angle ranged 77.36 ± 3.58 in children and 77.32 ± 4.88 in adults, while an average SNB angle was 79.46 ± 3.91 in the group of children and 81.12 ± 3.76 in adults. An average ANB angle was -2.10 ± 2.07 in children, and -4.00 ± 2.34 in adults. In both groups, a significant correlation between the measured values and a significant difference in the values of all the measured parameters were found between patients from different subgroups (p < 0.01. Conclusion. The most common morphological variation of sagittal position of the upper jaw is its retrognatism, which is equally present in both children and adults. Sagittal position of the lower jaw in most of the adults was prognathic, while mandible prognathism in the children was less present.

  20. Problems arising in differential diagnosis in the chest X-ray in patients with small sagittal diameter of the thorax

    International Nuclear Information System (INIS)

    Huebsch, P.; Stiglbauer, R.; Barton, P.; Frank, H.

    1989-01-01

    In patients with a small sagittal diameter of the thorax often carcia murmurs are heard. Since the p.a. chest X-ray in such cases often shows an enlarged heart shadow, problems arise in the interpretation of the films. In this paper, the typical appearance of the heart shadow in patients with small sagittal diameter of the thorax is described and the differential diagnosis is discussed. Echocardiography is the ideal additional diagnostic method, when problems in differential diagnosis occur. (orig.) [de

  1. All about alignment

    CERN Multimedia

    2006-01-01

    The ALICE absorbers, iron wall and superstructure have been installed with great precision. The ALICE front absorber, positioned in the centre of the detector, has been installed and aligned. Weighing more than 400 tonnes, the ALICE absorbers and the surrounding support structures have been installed and aligned with a precision of 1-2 mm, hardly an easy task but a very important one. The ALICE absorbers are made of three parts: the front absorber, a 35-tonne cone-shaped structure, and two small-angle absorbers, long straight cylinder sections weighing 18 and 40 tonnes. The three pieces lined up have a total length of about 17 m. In addition to these, ALICE technicians have installed a 300-tonne iron filter wall made of blocks that fit together like large Lego pieces and a surrounding metal support structure to hold the tracking and trigger chambers. The absorbers house the vacuum chamber and are also the reference surface for the positioning of the tracking and trigger chambers. For this reason, the ab...

  2. Nova laser alignment control system

    International Nuclear Information System (INIS)

    Van Arsdall, P.J.; Holloway, F.W.; McGuigan, D.L.; Shelton, R.T.

    1984-01-01

    Alignment of the Nova laser requires control of hundreds of optical components in the ten beam paths. Extensive application of computer technology makes daily alignment practical. The control system is designed in a manner which provides both centralized and local manual operator controls integrated with automatic closed loop alignment. Menudriven operator consoles using high resolution color graphics displays overlaid with transport touch panels allow laser personnel to interact efficiently with the computer system. Automatic alignment is accomplished by using image analysis techniques to determine beam references points from video images acquired along the laser chain. A major goal of the design is to contribute substantially to rapid experimental turnaround and consistent alignment results. This paper describes the computer-based control structure and the software methods developed for aligning this large laser system

  3. Onorbit IMU alignment error budget

    Science.gov (United States)

    Corson, R. W.

    1980-01-01

    The Star Tracker, Crew Optical Alignment Sight (COAS), and Inertial Measurement Unit (IMU) from a complex navigation system with a multitude of error sources were combined. A complete list of the system errors is presented. The errors were combined in a rational way to yield an estimate of the IMU alignment accuracy for STS-1. The expected standard deviation in the IMU alignment error for STS-1 type alignments was determined to be 72 arc seconds per axis for star tracker alignments and 188 arc seconds per axis for COAS alignments. These estimates are based on current knowledge of the star tracker, COAS, IMU, and navigation base error specifications, and were partially verified by preliminary Monte Carlo analysis.

  4. Alignment of helical membrane protein sequences using AlignMe.

    Directory of Open Access Journals (Sweden)

    Marcus Stamm

    Full Text Available Few sequence alignment methods have been designed specifically for integral membrane proteins, even though these important proteins have distinct evolutionary and structural properties that might affect their alignments. Existing approaches typically consider membrane-related information either by using membrane-specific substitution matrices or by assigning distinct penalties for gap creation in transmembrane and non-transmembrane regions. Here, we ask whether favoring matching of predicted transmembrane segments within a standard dynamic programming algorithm can improve the accuracy of pairwise membrane protein sequence alignments. We tested various strategies using a specifically designed program called AlignMe. An updated set of homologous membrane protein structures, called HOMEP2, was used as a reference for optimizing the gap penalties. The best of the membrane-protein optimized approaches were then tested on an independent reference set of membrane protein sequence alignments from the BAliBASE collection. When secondary structure (S matching was combined with evolutionary information (using a position-specific substitution matrix (P, in an approach we called AlignMePS, the resultant pairwise alignments were typically among the most accurate over a broad range of sequence similarities when compared to available methods. Matching transmembrane predictions (T, in addition to evolutionary information, and secondary-structure predictions, in an approach called AlignMePST, generally reduces the accuracy of the alignments of closely-related proteins in the BAliBASE set relative to AlignMePS, but may be useful in cases of extremely distantly related proteins for which sequence information is less informative. The open source AlignMe code is available at https://sourceforge.net/projects/alignme/, and at http://www.forrestlab.org, along with an online server and the HOMEP2 data set.

  5. An enhanced RNA alignment benchmark for sequence alignment programs

    Directory of Open Access Journals (Sweden)

    Steger Gerhard

    2006-10-01

    Full Text Available Abstract Background The performance of alignment programs is traditionally tested on sets of protein sequences, of which a reference alignment is known. Conclusions drawn from such protein benchmarks do not necessarily hold for the RNA alignment problem, as was demonstrated in the first RNA alignment benchmark published so far. For example, the twilight zone – the similarity range where alignment quality drops drastically – starts at 60 % for RNAs in comparison to 20 % for proteins. In this study we enhance the previous benchmark. Results The RNA sequence sets in the benchmark database are taken from an increased number of RNA families to avoid unintended impact by using only a few families. The size of sets varies from 2 to 15 sequences to assess the influence of the number of sequences on program performance. Alignment quality is scored by two measures: one takes into account only nucleotide matches, the other measures structural conservation. The performance order of parameters – like nucleotide substitution matrices and gap-costs – as well as of programs is rated by rank tests. Conclusion Most sequence alignment programs perform equally well on RNA sequence sets with high sequence identity, that is with an average pairwise sequence identity (APSI above 75 %. Parameters for gap-open and gap-extension have a large influence on alignment quality lower than APSI ≤ 75 %; optimal parameter combinations are shown for several programs. The use of different 4 × 4 substitution matrices improved program performance only in some cases. The performance of iterative programs drastically increases with increasing sequence numbers and/or decreasing sequence identity, which makes them clearly superior to programs using a purely non-iterative, progressive approach. The best sequence alignment programs produce alignments of high quality down to APSI > 55 %; at lower APSI the use of sequence+structure alignment programs is recommended.

  6. GraphAlignment: Bayesian pairwise alignment of biological networks

    Directory of Open Access Journals (Sweden)

    Kolář Michal

    2012-11-01

    Full Text Available Abstract Background With increased experimental availability and accuracy of bio-molecular networks, tools for their comparative and evolutionary analysis are needed. A key component for such studies is the alignment of networks. Results We introduce the Bioconductor package GraphAlignment for pairwise alignment of bio-molecular networks. The alignment incorporates information both from network vertices and network edges and is based on an explicit evolutionary model, allowing inference of all scoring parameters directly from empirical data. We compare the performance of our algorithm to an alternative algorithm, Græmlin 2.0. On simulated data, GraphAlignment outperforms Græmlin 2.0 in several benchmarks except for computational complexity. When there is little or no noise in the data, GraphAlignment is slower than Græmlin 2.0. It is faster than Græmlin 2.0 when processing noisy data containing spurious vertex associations. Its typical case complexity grows approximately as O(N2.6. On empirical bacterial protein-protein interaction networks (PIN and gene co-expression networks, GraphAlignment outperforms Græmlin 2.0 with respect to coverage and specificity, albeit by a small margin. On large eukaryotic PIN, Græmlin 2.0 outperforms GraphAlignment. Conclusions The GraphAlignment algorithm is robust to spurious vertex associations, correctly resolves paralogs, and shows very good performance in identification of homologous vertices defined by high vertex and/or interaction similarity. The simplicity and generality of GraphAlignment edge scoring makes the algorithm an appropriate choice for global alignment of networks.

  7. Mask alignment system for semiconductor processing

    Science.gov (United States)

    Webb, Aaron P.; Carlson, Charles T.; Weaver, William T.; Grant, Christopher N.

    2017-02-14

    A mask alignment system for providing precise and repeatable alignment between ion implantation masks and workpieces. The system includes a mask frame having a plurality of ion implantation masks loosely connected thereto. The mask frame is provided with a plurality of frame alignment cavities, and each mask is provided with a plurality of mask alignment cavities. The system further includes a platen for holding workpieces. The platen may be provided with a plurality of mask alignment pins and frame alignment pins configured to engage the mask alignment cavities and frame alignment cavities, respectively. The mask frame can be lowered onto the platen, with the frame alignment cavities moving into registration with the frame alignment pins to provide rough alignment between the masks and workpieces. The mask alignment cavities are then moved into registration with the mask alignment pins, thereby shifting each individual mask into precise alignment with a respective workpiece.

  8. The change of cervical spine alignment along with aging in asymptomatic population: a preliminary analysis.

    Science.gov (United States)

    Chen, Yiwei; Luo, Jiaquan; Pan, Zhimin; Yu, Limin; Pang, Long; Zhong, Junlong; Li, Zhiyun; Han, Zhimin; Cao, Kai

    2017-07-06

    A cross-sectional study. To investigate the correlation of cervical spine alignment changes with aging in asymptomatic population. Previous studies demonstrated the influence of lumbar and thoracic spine on cervical spine alignment, but few has reported the cervical spine alignment change along with aging in asymptomatic population. Asymptomatic population were divided into four groups according to different ages (Group A: ≤20 years; Group B: 21-40 years; Group C: 41-60 years; Group D: ≥61 years). Each group was composed of 30 subjects. The following parameters were measured: C0-1 Cobb angle, C1-2 Cobb angle, C2-7 Cobb angle, C1-7 sagittal vertical axis (C1-7 SVA), C2-7 SVA, central of gravity to C7 sagittal vertical axis (CG-C7 SVA), Thoracic Inlet Angle (TIA), Neck Tilt (NT), cervical tilt, cranial tilt, T1 slope (TS), TS-CL, and ANOVA statistical method was used to analyze the differences among four groups, and then, linear regression analysis was performed to analyze correlation of the cervical spine alignment with the aging. C1-7 SVA, C2-7 SVA, CG-C7 SVA, TIA, NT, TS, and cranial tilt were found statistically different among four groups (P aging. A gradual increase of TIA, NT, and TS, accompanied with an increased CL, is found along with aging in asymptomatic population, among which TIA, NT, and TS are significantly correlated with physiological nature of aging.

  9. Catalyzing alignment processes

    DEFF Research Database (Denmark)

    Lauridsen, Erik Hagelskjær; Jørgensen, Ulrik

    2004-01-01

    time and in combination with other social processes establish more aligned and standardized environmental performance between countries. However, examples of the introduction of environmental management suggests that EMS’ only plays a minor role in developing the actual environmental objectives......This paper describes how environmental management systems (EMS) spur the circulation of processes that support the constitution of environmental issues as specific environ¬mental objects and objectives. EMS catalyzes alignmentprocesses that produce coherence among the different elements involved....... They are here used to describe the context in which environmental management is implemented. Based on findings from contributions to a research program studying the implementation and impact of EMS in different settings, we highlight the diverse roles that these systems play in the Thai context. EMS may over...

  10. Biomechanical Comparison of Single- and Double-Leg Jump Landings in the Sagittal and Frontal Plane.

    Science.gov (United States)

    Taylor, Jeffrey B; Ford, Kevin R; Nguyen, Anh-Dung; Shultz, Sandra J

    2016-06-01

    Double-leg forward or drop-jump landing activities are typically used to screen for high-risk movement strategies and to determine the success of neuromuscular injury prevention programs. However, research suggests that these tasks that occur primarily in the sagittal plane may not adequately represent the lower extremity biomechanics that occur during unilateral foot contact or non-sagittal plane movements that are characteristic of many multidirectional sports. To examine the extent to which lower extremity biomechanics measured during a jump landing on a double leg (DL) after a sagittal plane (SAG) movement is representative of biomechanics measured during single-leg (SL) or frontal plane (FRONT) jump landing tasks. Controlled laboratory study. Lower extremity biomechanics were measured in 15 recreationally active females (mean age [±SD], 19.4 ± 2.1 years; mean height, 163.3 ± 5.9 cm; mean weight, 61.1 ± 7.1 kg) while performing SAGDL, SAGSL, FRONTDL, and FRONTSL jump landing tasks. Repeated-measures analyses of variance examined differences in lower extremity biomechanics between the 4 tasks, and linear regressions examined the extent to which an individual's biomechanics during SAGDL were representative of their biomechanics during SAGSL, FRONTDL, and FRONTSL. Lower extremity kinematics and kinetics differed by condition, with the SAGDL task generally eliciting greater hip and knee flexion angles and lower hip and knee forces than the other tasks (P plane jump landing tasks used to screen for ACL injury risk and the effectiveness of ACL injury prevention programs may not adequately represent the lower extremity biomechanics that occur during single-leg activities. These results support further investigation of single-leg multidirectional landings to identify high-risk movement strategies in female athletes playing multidirectional sports.

  11. Direct repair of the sagittal band for extensor tendon subluxation caused by finger flicking.

    Science.gov (United States)

    Hong, In Tae; Oh, Chi Hoon; Sim, Young Suk; Han, Soo Hong

    2017-09-01

    For patients with metacarpophalangeal (MCP) extensor tendon subluxation caused by finger flicking injury, we performed an extensor tendon realignment and direct repair technique. The purpose of this study was to evaluate the clinical outcome after direct repair of the sagittal band in patients with MCP extensor tendon subluxation caused by finger flicking injury and to introduce the repair technique. A total of 26 patients with a mean age of 39.9 years were included in the study. The mean time from injury to surgery was 51.3 days. The ruptured sagittal band was reattached to the lateral side of the extensor tendon using a continuous interlocking suture. Patients were evaluated for pain using a visual analog scale (VAS), range of motion, long fingertip pinch strength, disabilities of the arm, shoulder, and hand (DASH) score, and the recurrence of extensor tendon subluxation or dislocation. All patients had full range of motion compared to the uninjured contralateral digit. Long fingertip pinch strength was also comparable to that of the contralateral digit in all patients. The DASH score was also improved from a preoperative average of 28.8 to a postoperative average of 1.0. Realignment of the extensor tendon and direct repair of the superficial layer of the sagittal band to the extensor digitorum communis (EDC) tendon is recommended as a treatment option in patients with chronic MCP extensor tendon subluxation, as well as for acute MCP extensor tendon subluxation in patients that have failed or could not maintain conservative treatment approaches.

  12. Differences in erect sitting and natural sitting spinal alignment-insights into a new paradigm and implications in deformity correction.

    Science.gov (United States)

    Hey, Hwee Weng Dennis; Wong, Chengyuan Gordon; Lau, Eugene Tze-Chun; Tan, Kimberly-Anne; Lau, Leok-Lim; Liu, Ka-Po Gabriel; Wong, Hee-Kit

    2017-02-01

    Sitting spinal alignment is increasingly recognized as a factor influencing strategy for deformity correction. Considering that most individuals sit for longer hours in a "slumped" rather than in an erect posture, greater understanding of the natural sitting posture is warranted. This study aimed to investigate the differences in sagittal spinal alignment between two common sitting postures: a natural, patient-preferred posture; and an erect, investigator-controlled posture that is commonly used in alignment studies. This is a randomized, prospective study of 28 young, healthy patients seen in a tertiary hospital over a 6-month period. Twenty-eight patients (24 men, 4 women), with a mean age of 24 years (range 19-38), were recruited for this study. All patients with first episode of lower back pain of less than 3 months' duration were included. The exclusion criteria consisted of previous spinal surgery, radicular symptoms, red flag symptoms, previous spinal trauma, obvious spinal deformity on forward bending test, significant personal or family history of malignancy, and current pregnancy. Radiographic measurements included sagittal vertical axis (SVA), lumbar lordosis (LL), thoracolumbar angle (TL), thoracic kyphosis (TK), and cervical lordosis (CL). Standard spinopelvic parameters (pelvic incidence, pelvic tilt [PT], and sacral slope) and sagittal apex and end vertebrae were also measured. Basic patient demographics (age, gender, ethnicity) were recorded. Lateral sitting whole spine radiographs were obtained using a slot scanner in the imposed erect and the natural sitting posture. Statistical analyses of the radiographical parameters were performed comparing the two sitting postures using chi-squared tests for categorical variables and paired t tests for continuous variables. There was forward SVA shift between the two sitting postures by a mean of 2.9 cm (psitting posture, the lumbar spine becomes kyphotic and contributes to a single C-shaped sagittal

  13. Sagittal standing posture, back pain, and quality of life among adults from the general population: a sex-specific association.

    Science.gov (United States)

    Araújo, Fábio; Lucas, Raquel; Alegrete, Nuno; Azevedo, Ana; Barros, Henrique

    2014-06-01

    A prospective radiographical study of sagittal standing posture among adults consecutively recruited from the general population. To analyze the relation of suboptimal sagittal standing posture with back pain and health-related quality of life in general adult males and females. Clinical studies have shown the association of sagittal standing posture with pain and reduced quality of life, but this relation has not been assessed in the general adult population. As part of the EPIPorto population-based study of adults, 178 males and 311 females were evaluated. Age, education, and body mass index were recorded. Radiographical data collection consisted of 36-in. standing sagittal radiographs. Creation of 3 groups for individual spinopelvic parameters was performed (low, intermediate, or high), and 1 of 4 sagittal types of postural patterns attributed to each participant (Roussouly classification). Back pain prevalence and severity were assessed on the basis of self-reported data and health-related quality of life using 2 main components of the 36-Item Short Form Health Survey. In males, differences in back pain severity were observed only among pelvic tilt/pelvic incidence ratio groups. Females presenting high pelvic incidence and sacral slope exhibited higher odds of severe back pain than those with intermediate values (adjusted odds ratios = 2.21 and 2.15; 95% confidence interval, 1.24-3.97 and 1.21-3.86; respectively). Sagittal vertical axis showed the largest differences in physical quality of life of females: high group had 8.8 lower score than the low group (P posture was not consistently associated with quality of life measures in males. Increased pelvic incidence and sacral slope may be involved in causing severe back pain among females. Monitoring sagittal postural parameters has limited usefulness as a screening tool for causes of unspecific musculoskeletal symptoms in the general adult population. 3.

  14. A clinico-radiographic analysis of sagittal condylar guidance determined by protrusive interocclusal registration and panoramic radiographic images in humans

    Directory of Open Access Journals (Sweden)

    D Krishna Prasad

    2012-01-01

    Full Text Available Purpose: To evaluate the correlation between sagittal condylar guidance obtained by protrusive interocclusal records and panoramic radiograph tracing methods in human dentulous subjects. Materials and Methods: The sagittal condylar guidance was determined in 75 dentulous subjects by protrusive interocclusal records using Aluwax through a face bow transfer (HANAU™ Spring Bow, Whip Mix Corporation, USA to a semi-adjustable articulator (HANAU™ Wide-Vue Articulator, Whip Mix Corporation, USA. In the same subjects, the sagittal outline of the articular eminence and glenoid fossa was traced in panoramic radiographs. The sagittal condylar path inclination was constructed by joining the heights of curvature in the glenoid fossa and the corresponding articular eminence. This was then related to the constructed Frankfurt′s horizontal plane to determine the radiographic angle of sagittal condylar guidance. Results: A strong positive correlation existed between right and left condylar guidance by the protrusive interocclusal method (P 0.000 and similarly by the radiographic method (P 0.013. The mean difference between the condylar guidance obtained using both methods were 1.97° for the right side and 3.18° for the left side. This difference between the values by the two methods was found to be highly significant for the right (P 0.003 and left side (P 0.000, respectively. The sagittal condylar guidance obtained from both methods showed a significant positive correlation on right (P 0.000 and left side (P 0.015, respectively. Conclusion: Panoramic radiographic tracings of the sagittal condylar path guidance may be made relative to the Frankfurt′s horizontal reference plane and the resulting condylar guidance angles used to set the condylar guide settings of semi-adjustable articulators.

  15. Central uplift of custom immobilization radiotherapy patients with lower limb overhead sagittal laser affected without mobile

    International Nuclear Information System (INIS)

    Velazquez Miranda, S.; Delgado Gil, M. M.; Ortiz Seidel, M.

    2011-01-01

    If you have a laser moving overhead sagittal or the location of tumors in the lower extremities is laborious, as to reference properly in the CT, is necessary before tattooing in the treatment table using their ability to relate the lateral midline with tattoos on the limb. For anatomical forms often happens that lasers are not displayed on the areas of our interest. The problem can be overcome if between the legs raise the bag or custom immobilizer above the height of the patient's abdomen, as this will have a central reference reliable and well designed lasers.

  16. Brief communication: age and fractal dimensions of human sagittal and coronal sutures

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Jacobsen, Jens Christian Brings

    2003-01-01

    The fractal dimensions of human sagittal and coronal sutures were calculated on 31 complete skulls from the Terry Collection. The aim was to investigate whether the fractal dimension, relying on the whole sutural length, might yield a better description of age-related changes in sutural morphology......, as opposed to other methods of quantification, which generally rely on more arbitrary scoring systems. However, the fractal dimension did not yield better age correlations than other previously described methods. At best, the results reflected the general observation that young adults below age 40 years...

  17. Using smartphones in the evaluation of spinal curvatures in a sagittal plane

    Directory of Open Access Journals (Sweden)

    Waś Jakub

    2016-12-01

    Full Text Available Introduction: In physiotherapeutic diagnostic processes, various tools and methods may be used. However, price and availability may limit their daily use in clinical practice. Therefore, the suggestion that smartphones with specific applications may be useful as diagnostic tools can be found in the literature. However, before using them in clinical practice, it is important to verify their reliability. The aim of the study was to evaluate the consistency of measurements of the curvatures in the sagittal plane performed with the Saunders digital inclinometer and a smartphone application.

  18. An incidental persistent falcine sinus with dominant straight sinus and hypoplastic distal superior sagittal sinus

    Energy Technology Data Exchange (ETDEWEB)

    Manoj, Krishnan Sarojam [Metroscans, Trivandrum (India); Krishnamoorthy, Thamburaj; Thomas, Bejoy; Kapilamoorthy, Tirur Raman [Sree Chitra Tirunal Institute for Medical Sciences and Technology, Department of Imaging Sciences and Interventional Radiology, Trivandrum (India)

    2006-01-01

    An incidental persistent falcine sinus was detected in an otherwise normal brain on MRI in a 12-year-old girl who underwent imaging after clinical suspicion of acute disseminated encephalomyelitis. The falcine sinus was associated with a hypoplastic posterior third of the superior sagittal sinus and a dominant straight sinus. Generally, atresia or hypoplasia of the straight sinus is associated with a persistent falcine sinus in postnatal life; otherwise, the falcine sinus disappears before birth. We discuss the embryological basis for such an association in this case. (orig.)

  19. Papilledema secondary to a superior sagittal sinus thrombosis. Mantle cell lymphoma paraneoplastic syndrome.

    Science.gov (United States)

    Platas-Moreno, I; Antón-Benito, A; Pérez-Cid-Rebolleda, M T; Rosado Sierra, M B

    2016-01-01

    A 46 year old patient presented with visual loss in the left eye during the previous months. Ophthalmoscopic examination and magnetic resonance angiography found the presence of papilledema due to thrombosis in superior sagittal sinus. The examination findings revealed a mantle cell lymphoma. Cerebral venous thrombosis is an unusual cause of papilledema. This type of thrombosis may be secondary to hyper-viscosity within a context of a paraneoplastic syndrome. Copyright © 2015 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  20. Lexical alignment in triadic communication

    Directory of Open Access Journals (Sweden)

    Anouschka eFoltz

    2015-02-01

    Full Text Available Lexical alignment refers to the adoption of one’s interlocutor’s lexical items. Accounts of the mechanisms underlying such lexical alignment differ (among other aspects in the role assigned to addressee-centered behavior. In this study, we used a triadic communicative situation to test which factors may modulate the extent to which participants’ lexical alignment reflects addressee-centered behavior. Pairs of naïve participants played a picture matching game and received information about the order in which pictures were to be matched from a voice over headphones. On critical trials, participants did or did not hear a name for the picture to be matched next over headphones. Importantly, when the voice over headphones provided a name, it did not match the name that the interlocutor had previously used to describe the object. Participants overwhelmingly used the word that the voice over headphones provided. This result points to non-addressee-centered behavior and is discussed in terms of disrupting alignment with the interlocutor as well as in terms of establishing alignment with the voice over headphones. In addition, the type of picture (line drawing vs. tangram shape independently modulated lexical alignment, such that participants showed more lexical alignment to their interlocutor for (more ambiguous tangram shapes compared to line drawings. Overall, the results point to a rather large role for non-addressee-centered behavior during lexical alignment.

  1. CATO: The Clone Alignment Tool.

    Directory of Open Access Journals (Sweden)

    Peter V Henstock

    Full Text Available High-throughput cloning efforts produce large numbers of sequences that need to be aligned, edited, compared with reference sequences, and organized as files and selected clones. Different pieces of software are typically required to perform each of these tasks. We have designed a single piece of software, CATO, the Clone Alignment Tool, that allows a user to align, evaluate, edit, and select clone sequences based on comparisons to reference sequences. The input and output are designed to be compatible with standard data formats, and thus suitable for integration into a clone processing pipeline. CATO provides both sequence alignment and visualizations to facilitate the analysis of cloning experiments. The alignment algorithm matches each of the relevant candidate sequences against each reference sequence. The visualization portion displays three levels of matching: 1 a top-level summary of the top candidate sequences aligned to each reference sequence, 2 a focused alignment view with the nucleotides of matched sequences displayed against one reference sequence, and 3 a pair-wise alignment of a single reference and candidate sequence pair. Users can select the minimum matching criteria for valid clones, edit or swap reference sequences, and export the results to a summary file as part of the high-throughput cloning workflow.

  2. Vacuum Alignment with more Flavors

    DEFF Research Database (Denmark)

    Ryttov, Thomas

    2014-01-01

    We study the alignment of the vacuum in gauge theories with $N_f$ Dirac fermions transforming according to a complex representation of the gauge group. The alignment of the vacuum is produced by adding a small mass perturbation to the theory. We study in detail the $N_f=2,3$ and $4$ case. For $N_...

  3. The CMS Silicon Tracker Alignment

    CERN Document Server

    Castello, R

    2008-01-01

    The alignment of the Strip and Pixel Tracker of the Compact Muon Solenoid experiment, with its large number of independent silicon sensors and its excellent spatial resolution, is a complex and challenging task. Besides high precision mounting, survey measurements and the Laser Alignment System, track-based alignment is needed to reach the envisaged precision.\\\\ Three different algorithms for track-based alignment were successfully tested on a sample of cosmic-ray data collected at the Tracker Integration Facility, where 15\\% of the Tracker was tested. These results, together with those coming from the CMS global run, will provide the basis for the full-scale alignment of the Tracker, which will be carried out with the first \\emph{p-p} collisions.

  4. Self-learning computers for surgical planning and prediction of postoperative alignment.

    Science.gov (United States)

    Lafage, Renaud; Pesenti, Sébastien; Lafage, Virginie; Schwab, Frank J

    2018-02-01

    In past decades, the role of sagittal alignment has been widely demonstrated in the setting of spinal conditions. As several parameters can be affected, identifying the driver of the deformity is the cornerstone of a successful treatment approach. Despite the importance of restoring sagittal alignment for optimizing outcome, this task remains challenging. Self-learning computers and optimized algorithms are of great interest in spine surgery as in that they facilitate better planning and prediction of postoperative alignment. Nowadays, computer-assisted tools are part of surgeons' daily practice; however, the use of such tools remains to be time-consuming. NARRATIVE REVIEW AND RESULTS: Computer-assisted methods for the prediction of postoperative alignment consist of a three step analysis: identification of anatomical landmark, definition of alignment objectives, and simulation of surgery. Recently, complex rules for the prediction of alignment have been proposed. Even though this kind of work leads to more personalized objectives, the number of parameters involved renders it difficult for clinical use, stressing the importance of developing computer-assisted tools. The evolution of our current technology, including machine learning and other types of advanced algorithms, will provide powerful tools that could be useful in improving surgical outcomes and alignment prediction. These tools can combine different types of advanced technologies, such as image recognition and shape modeling, and using this technique, computer-assisted methods are able to predict spinal shape. The development of powerful computer-assisted methods involves the integration of several sources of information such as radiographic parameters (X-rays, MRI, CT scan, etc.), demographic information, and unusual non-osseous parameters (muscle quality, proprioception, gait analysis data). In using a larger set of data, these methods will aim to mimic what is actually done by spine surgeons, leading

  5. Alignment-Annotator web server: rendering and annotating sequence alignments.

    Science.gov (United States)

    Gille, Christoph; Fähling, Michael; Weyand, Birgit; Wieland, Thomas; Gille, Andreas

    2014-07-01

    Alignment-Annotator is a novel web service designed to generate interactive views of annotated nucleotide and amino acid sequence alignments (i) de novo and (ii) embedded in other software. All computations are performed at server side. Interactivity is implemented in HTML5, a language native to web browsers. The alignment is initially displayed using default settings and can be modified with the graphical user interfaces. For example, individual sequences can be reordered or deleted using drag and drop, amino acid color code schemes can be applied and annotations can be added. Annotations can be made manually or imported (BioDAS servers, the UniProt, the Catalytic Site Atlas and the PDB). Some edits take immediate effect while others require server interaction and may take a few seconds to execute. The final alignment document can be downloaded as a zip-archive containing the HTML files. Because of the use of HTML the resulting interactive alignment can be viewed on any platform including Windows, Mac OS X, Linux, Android and iOS in any standard web browser. Importantly, no plugins nor Java are required and therefore Alignment-Anotator represents the first interactive browser-based alignment visualization. http://www.bioinformatics.org/strap/aa/ and http://strap.charite.de/aa/. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  6. THE IMPACT OF PILATES EXERCISES ON THE POSTURAL ALIGNMENT OF HEALTHY ADULTS

    Directory of Open Access Journals (Sweden)

    Bruna Krawczky

    Full Text Available ABSTRACT Introduction: Exercises of Pilates method have been widely used to improve postural alignment. There is strong evidence favoring their use in improving flexibility and balance, as well as some evidence of improvement in muscle strength. However, the benefits related to posture are not well established. Objective: To investigate in healthy adults, the impact of the Pilates method in the postural alignment through some angles in the sagittal plane and the occurrence of pain before and after an exercise session, and after the completion of a 16-session program. Methods: This is a quasi-experimental study of pre and post-intervention type. Healthy adults (n = 37 interested in starting Pilates were evaluated for acute effects on posture after a Pilates session (n = 37 and after a 16-session program, for a period of 10 weeks (n = 13. Using the postural assessment software (SAPO, six angles were analyzed: head horizontal alignment (HHA, pelvis horizontal alignment (PHA, hip angle (HA, vertical alignment of the body (VAB, thoracic kyphosis (TK, and lumbar lordosis (LL. The occurrence of pain was investigated to control adverse effects. Results: Statistically significant (p<0.05 differences found after one session include increased HHA (left view, decreased VAB (left view and TK (both side views. After 16 sessions, we observed an increase of HHA, and a decrease of TK, LL (both side views and HA (right view. All the differences point to an improvement of postural alignment. A significant reduction of prevalence of pain was verified after the first session (40.5% vs. 13.5%; p=0.004 and after the full program (30.8% vs. 15.3%; p=0.02. Conclusions: Our results suggest that the Pilates method has a positive impact on postural alignment in healthy adults, besides being a safe exercise.

  7. Prenatal MR imaging of Dandy-Walker complex: Midline sagittal area analysis

    International Nuclear Information System (INIS)

    Wong, Alex M.; Bilaniuk, Larissa T.; Zimmerman, Robert A.; Liu, P.L.

    2012-01-01

    Objective: To measure the mid-sagittal areas of vermis (VA) and of posterior fossa (PFA) and determine their differences among fetuses with various Dandy-Walker (DW) entities and control subjects. Methods: We reviewed data in 25 fetal patients with a MR diagnosis of DW complex including hypoplastic vermis (HV), HV with rotation (HVR), and mega cistern magna (MCM), and in 85 fetal controls with normal CNS. PFA and VA of each subject were manually traced on mid-sagittal MR images. Regarding each of VA and PFA, after age correction, we determined statistically significant differences among HVR, HV, MCM, and control groups. Results: The mean VA residue of MCM was greater than that of the control, which was in turn greater than those of HVR and HV. The mean PF residue of the control was smaller than all other groups. Conclusion: Fetuses with HVR or HV had smaller VA than fetuses with MCM or control subjects. Fetuses with MCM, HVR, or HV had larger PFA than control subjects. These results may be an early step leading to better understanding of the confusion about the PF anomalies in future.

  8. Skull fracture with effacement of the superior sagittal sinus following drone impact: a case report.

    Science.gov (United States)

    Chung, Lawrance K; Cheung, Yuri; Lagman, Carlito; Au Yong, Nicholas; McBride, Duncan Q; Yang, Isaac

    2017-09-01

    The popularity of unmanned aerial vehicles, or drones, raises safety concerns as they become increasingly common for commercial, personal, and recreational use. Collisions between drones and people may result in serious injuries. A 13-year-old male presented with a comminuted depressed skull fracture causing effacement of the superior sagittal sinus secondary to a racing drone impact. The patient experienced a brief loss of consciousness and reported lower extremity numbness and weakness after the accident. Imaging studies revealed bone fragments crossing the superior sagittal sinus with a short, focal segment of blood flow interruption. Neurosurgical intervention was deferred given the patient's improving neurological deficits, and the patient was treated conservatively. He was discharged home in stable condition. Drones may represent a hazard when operated inappropriately due to their capacity to fly at high speeds and altitudes. Impacts from drones can carry enough force to cause skull fractures and significant head injuries. The rising popularity of drones likely translates to an increased incidence of drone-related injuries. Thus, clinicians should be aware of this growing trend.

  9. Flow velocity of the superior sagittal sinus is reduced in patients with idiopathic normal pressure hydrocephalus.

    Science.gov (United States)

    Kuriyama, Nagato; Tokuda, Takahiko; Yamada, Kei; Akazawa, Kentaro; Hosoda, Makoto; Sakai, Koji; Watanabe, Yoshiyuki; Nakagawa, Masanori

    2011-10-01

    The pathogenesis and diagnostic methods for idiopathic normal pressure hydrocephalus (iNPH) have been active areas of research in recent years. This study was performed to determine whether there is a venous return abnormality in the intracranial circulation of patients with iNPH. The subjects were 20 patients with iNPH (Group N) and 24 normal controls (Group C). MR venography (MRV) was performed at the superior sagittal sinus 2 cm above the confluence of the sinuses, and the flow velocities were compared between Groups N and C. During normal breathing, the maximum velocities were significantly lower in Group N (18.8 cm/second) than in Group C (22.9 cm/second; (P velocity decreased in both groups, but both the maximum (Max V) and minimum (Min V) velocities were significantly lower in Group N than in Group C (P velocity at the superior sagittal sinus was lower and the flow velocity during the Valsalva maneuver decreased more in patients with iNPH than in controls. The results may reflect the presence of abnormal intracranial venous flow in iNPH. © 2010 by the American Society of Neuroimaging.

  10. Risk factors for breakage of biodegradable plate systems after bilateral sagittal split mandibular setback surgery.

    Science.gov (United States)

    Yoshioka, Izumi; Igawa, Kaori; Nagata, Jyunko; Yoshida, Maho; Baba, Takashi; Ichiki, Takeshi; Kondoh, Yudai; Takamori, Koichi; Kashima, Koji; Sakoda, Sumio

    2013-06-01

    The aim of this retrospective study was to evaluate the risk factors associated with breakage of biodegradable plate systems after bilateral sagittal split mandibular setback. We studied 169 Japanese adults (62 men, 107 women; age range 16-53 years) with deformities of the jaw diagnosed as mandibular prognathism. All patients were treated by bilateral sagittal split osteotomy (BSSO) with 2 biodegradable fixation plates and screws at the anterior mandibular ramus. We collected the following data from the medical records and radiological findings: sex; age; degree of setback; presence of asymmetry; presence of open bite; operation; design of the plate; operating time; and blood loss. Multiple logistic regression analysis was used to find the factors that were independently associated with the dependent variable: breakage of the biodegradable plate system. In 10 of the 169 patients (6%) the biodegradable plate system for the BSSO broke. Factors that influenced whether or not the biodegradable plate system fractured were if they were asymmetrical (odds ratio (OR) 5.35; P=0.02) and had an open bite (OR 5.20; P=0.02). Asymmetry or open bite was significantly associated with breaks in the biodegradable plate system. Biodegradable plates should be used only when loading is minimal. Copyright © 2012 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Normal development of brainstem in childhood. Measurement of the area on mid-sagittal MR imaging

    International Nuclear Information System (INIS)

    Kutomi, Kimiko

    2005-01-01

    Developmental abnormality of brainstem is shown in pediatric patients with mental retardation, autism, periventricular leukomalacia, neurodegenerative disease, and so on. Our purpose here is to clarify the normal developmental pattern of the brainstem. We measured the area of tectum, midbrain tegmentum, pons, basis pontis and pontine tegmentum on mid-sagittal MR images in 111 children (newborn to 20 year old). Different growth patterns were shown in all parts of the brainstem. Tectum showed a subtle increase in area from the newborn to adult period, while midbrain tegmentum and pontine tegmenturn showed a mild and gradual increase in area. Pons and pontine tegmentum showed a rapid and prominent increase in area from newborn to infant period and gradual increase in area until the adult period. These different growth patterns seemed to be consistent with differences in the myelination cycles of the neuronal fibers, maturation of the nuclei and proliferation of glial cells in each part of the brainstem. Mid-sagittal MR imaging of the head is accurate and reproducible and is used conveniently in routine head MR study, making it very useful for the diagnosis of many central nervous diseases and anomalies. We believe that this new milestone provided in this study will be helpful in distinguishing normal children from those that have neurodegenerative disorders. (author)

  12. Current concepts on the sagittal balance and classification of spondylolysis and spondylolisthesis☆☆☆

    Science.gov (United States)

    Tebet, Marcos Antonio

    2014-01-01

    Treatment of spondylolysis and spondylolisthesis remains a challenge for orthopaedic surgeons, neurosurgeons and paediatrics. In spondylolisthesis, it has been clearly demonstrated over the past decade that spino-pelvic morphology is abnormal and that it can be associated to an abnormal sacro-pelvic orientation as well as to a disturbed global sagittal balance of spine. This article presents the SDSG (Spinal Deformity Study Group) classification of lumbosacral spondylolisthesis. The proper treatment of spondylolisthesis is dependent on recognizing the type of slip, sacro-pelvic balance and overall sagittal balance and its natural history. Although a number of clinical radiographic features have been identified as risk factors, their role as primary causative factors or secondary adaptative changes is not clear. The conservative treatment of adult isthmic spondylolisthesis results in good outcome in the majority of cases. Of those patients who fail conservative treatment, success with surgery is quite good, with significant improvement in neurologic function in those patients with deficits, as well as improvement in patients with back pain. PMID:26229765

  13. Measuring the Reliability of Sagittal Facial Anthropometric Measurements under Soft Tissue Displacement Using a Modified Ruler

    Directory of Open Access Journals (Sweden)

    Faramarz Mojtahedzadeh

    2013-01-01

    Full Text Available Objective: Despite the current use of radiography for quantifying sagittal skeletal measurements, it is an unsuitable way for screening or epidemiologic purposes. Although not fully approved, anthropometric measurements have been suggested as a substitute, and considering displacement of soft tissues, could possibly lead to more consistent results. The purpose of this study was to evaluate the reliability of anthropometric anteroposterior facial measurements under soft tissue compression using a special ruler.Material and Methods: Anthropometric measurements were done with a specifically designed sliding ruler twice on 36 adult patients with a 14 day lag between two measurements. The ruler measured the distance between the external acoustic meatus and the nasion (Na, subnasal (Sn point and the soft tissue pogonion (Pog. The soft tissue was displaced during measurements only to the extent that the underlying hard tissue resistance was felt subjectively by each assessor. The intraclass correlation coefficient (ICC was calculated for both inter- and intra- rater measurements using SPSS software.Results: All measurements had inter- and intrarater agreements above 0.9, with only a few parameters having lower bound confidence intervals below 0.9, but more than 0.8.Conclusion: Sagittal facial anthropometric measurements under soft tissue displacement using the specific ruler are valid and reliable and could possibly aid orthodontists in chairside craniofacial assessments.

  14. Sagittal MR findings of L5 spondylolysis : changes of spinal canal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Cheol; Choi, Woo Suk; Kim, Eui Jong; Ryu, Kyung Nam; Oh, Joo Hyeong; Kim, Ihn Sub; Yoon, Yup [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1997-07-01

    To evaluate changes in the spinal canal in cases of L5 spondylolysis, as seen on sagittal MR images. We retrospectively analysed the MR findings of 27 patients suffering from L5 spondylolysis without spondylolisthesis and compared them with 100 control subjects. Spondylolysis had been confirmed by conventional radiography. On midsagittal MR images, sagittal canal ratio (SCR) was defined as midsagittal canal diameter at L5 devided by that at L1. We analysed the frequency of posterior epidural fat deposition(posterior epidural fat between the posterior margin of the dural sac and the anterior cortical margin of the spinous process on the midsagittal line), and compared this with the frequency in 100 control subjects. Mean SCR value in 27 patients with L5 spondylolysis(1.22) was significantly greater than 100 control subjects(0.96, p<0.001). Mean SCR value in 17 patients with L5 spondylolysis and posterior epidural fat deposition(1.27) was significantly higher than in nine control subjects with posterior epidural fat deposition(0.97). Posterior epidural fat deposition was more frequently indentified in patients with L5 spondylolysis(63%) than in control subjects(9%). The possibility of L5 spondylolysis is suggested when on midsaggital MR imaging, the anteroposterior diameter of the L5 spinal canal is seen to be widened and posterior epidural fat deposition is noted.

  15. Sagittal MR findings of L5 spondylolysis : changes of spinal canal

    International Nuclear Information System (INIS)

    Kim, Hyun Cheol; Choi, Woo Suk; Kim, Eui Jong; Ryu, Kyung Nam; Oh, Joo Hyeong; Kim, Ihn Sub; Yoon, Yup

    1997-01-01

    To evaluate changes in the spinal canal in cases of L5 spondylolysis, as seen on sagittal MR images. We retrospectively analysed the MR findings of 27 patients suffering from L5 spondylolysis without spondylolisthesis and compared them with 100 control subjects. Spondylolysis had been confirmed by conventional radiography. On midsagittal MR images, sagittal canal ratio (SCR) was defined as midsagittal canal diameter at L5 devided by that at L1. We analysed the frequency of posterior epidural fat deposition(posterior epidural fat between the posterior margin of the dural sac and the anterior cortical margin of the spinous process on the midsagittal line), and compared this with the frequency in 100 control subjects. Mean SCR value in 27 patients with L5 spondylolysis(1.22) was significantly greater than 100 control subjects(0.96, p<0.001). Mean SCR value in 17 patients with L5 spondylolysis and posterior epidural fat deposition(1.27) was significantly higher than in nine control subjects with posterior epidural fat deposition(0.97). Posterior epidural fat deposition was more frequently indentified in patients with L5 spondylolysis(63%) than in control subjects(9%). The possibility of L5 spondylolysis is suggested when on midsaggital MR imaging, the anteroposterior diameter of the L5 spinal canal is seen to be widened and posterior epidural fat deposition is noted

  16. Incomplete oblique sagittal fractures of the dorsal cortex of the third metacarpal bone in six horses

    International Nuclear Information System (INIS)

    Watt, B.C.; Foerner, J.J.; Haines, G.R.

    1998-01-01

    To describe incomplete oblique sagittal dorsal cortical fractures of the equine third metacarpal bone, their surgical repair, and subsequent performance of the horses. Retrospective examination of medical records and racing performance. Six Thoroughbred race horses, 2 to 4 years of age. Radiographic confirmation of all fractures preceded general anesthesia and surgical correction. Three fractures were treated by intracortical compression using screws placed in lag fashion, and five fractures were treated by osteostixis. Race records were reviewed for each horse to determine performance after surgery. Fractures were best observed on palmarodorsal radiographic projections. Three horses treated by intracortical compression returned to racing, but fracture recurred in one horse and was treated by osteostixis. This horse and the other three horses treated by osteostixis raced after surgery. Horses with incomplete oblique sagittal fractures of the dorsal cortex of the third metacarpal bone can race after surgical management of the fracture by screws placed in lag fashion or osteostixis. The authors' preferred surgical procedure for managing this fracture is osteostixis. Palmarodorsal radiographic projections of the third metacarpal bone are recommended in young Thoroughbred race horses suspected of having dorsal metacarpal stress fractures

  17. Preliminary results of anterior lumbar interbody fusion, anterior column realignment for the treatment of sagittal malalignment.

    Science.gov (United States)

    Hosseini, Pooria; Mundis, Gregory M; Eastlack, Robert K; Bagheri, Ramin; Vargas, Enrique; Tran, Stacie; Akbarnia, Behrooz A

    2017-12-01

    OBJECTIVE Sagittal malalignment decreases patients' quality of life and may require surgical correction to achieve realignment goals. High-risk posterior-based osteotomy techniques are the current standard treatment for addressing sagittal malalignment. More recently, anterior lumbar interbody fusion, anterior column realignment (ALIF ACR) has been introduced as an alternative for correction of sagittal deformity. The objective of this paper was to report clinical and radiographic results for patients treated using the ALIF-ACR technique. METHODS A retrospective study of 39 patients treated with ALIF ACR was performed. Patient demographics, operative details, radiographic parameters, neurological assessments, outcome measures, and preoperative, postoperative, and mean 1-year follow-up complications were studied. RESULTS The patient population comprised 39 patients (27 females and 12 males) with a mean follow-up of 13.3 ± 4.7 months, mean age of 66.1 ± 11.6 years, and mean body mass index of 27.3 ± 6.2 kg/m 2 . The mean number of ALIF levels treated was 1.5 ± 0.5. Thirty-three (84.6%) of 39 patients underwent posterior spinal fixation and 33 (84.6%) of 39 underwent posterior column osteotomy, of which 20 (60.6%) of 33 procedures were performed at the level of the ALIF ACR. Pelvic tilt, sacral slope, and pelvic incidence were not statistically significantly different between the preoperative and postoperative periods and between the preoperative and 1-year follow-up periods (except for PT between the preoperative and 1-year follow-up, p = 0.018). Sagittal vertical axis, T-1 spinopelvic inclination, lumbar lordosis, pelvic incidence-lumbar lordosis mismatch, intradiscal angle, and motion segment angle all improved from the preoperative to postoperative period and the preoperative to 1-year follow-up (p < 0.05). The changes in motion segment angle and intradiscal angle achieved in the ALIF-ACR group without osteotomy compared with the ALIF-ACR group with osteotomy

  18. Validity of a smartphone protractor to measure sagittal parameters in adult spinal deformity.

    Science.gov (United States)

    Kunkle, William Aaron; Madden, Michael; Potts, Shannon; Fogelson, Jeremy; Hershman, Stuart

    2017-10-01

    Smartphones have become an integral tool in the daily life of health-care professionals (Franko 2011). Their ease of use and wide availability often make smartphones the first tool surgeons use to perform measurements. This technique has been validated for certain orthopedic pathologies (Shaw 2012; Quek 2014; Milanese 2014; Milani 2014), but never to assess sagittal parameters in adult spinal deformity (ASD). This study was designed to assess the validity, reproducibility, precision, and efficiency of using a smartphone protractor application to measure sagittal parameters commonly measured in ASD assessment and surgical planning. This study aimed to (1) determine the validity of smartphone protractor applications, (2) determine the intra- and interobserver reliability of smartphone protractor applications when used to measure sagittal parameters in ASD, (3) determine the efficiency of using a smartphone protractor application to measure sagittal parameters, and (4) elucidate whether a physician's level of experience impacts the reliability or validity of using a smartphone protractor application to measure sagittal parameters in ASD. An experimental validation study was carried out. Thirty standard 36″ standing lateral radiographs were examined. Three separate measurements were performed using a marker and protractor; then at a separate time point, three separate measurements were performed using a smartphone protractor application for all 30 radiographs. The first 10 radiographs were then re-measured two more times, for a total of three measurements from both the smartphone protractor and marker and protractor. The parameters included lumbar lordosis, pelvic incidence, and pelvic tilt. Three raters performed all measurements-a junior level orthopedic resident, a senior level orthopedic resident, and a fellowship-trained spinal deformity surgeon. All data, including the time to perform the measurements, were recorded, and statistical analysis was performed to

  19. Aligning for Innovation - Alignment Strategy to Drive Innovation

    Science.gov (United States)

    Johnson, Hurel; Teltschik, David; Bussey, Horace, Jr.; Moy, James

    2010-01-01

    With the sudden need for innovation that will help the country achieve its long-term space exploration objectives, the question of whether NASA is aligned effectively to drive the innovation that it so desperately needs to take space exploration to the next level should be entertained. Authors such as Robert Kaplan and David North have noted that companies that use a formal system for implementing strategy consistently outperform their peers. They have outlined a six-stage management systems model for implementing strategy, which includes the aligning of the organization towards its objectives. This involves the alignment of the organization from the top down. This presentation will explore the impacts of existing U.S. industrial policy on technological innovation; assess the current NASA organizational alignment and its impacts on driving technological innovation; and finally suggest an alternative approach that may drive the innovation needed to take the world to the next level of space exploration, with NASA truly leading the way.

  20. Alignment control of GEO 600

    International Nuclear Information System (INIS)

    Grote, H; Heinzel, G; Freise, A; Gossler, S; Willke, B; Lueck, H; Ward, H; Casey, M M; Strain, K A; Robertson, D I; Hough, J; Danzmannx, K

    2004-01-01

    We give an overview of the automatic mirror alignment system of the gravitational wave detector GEO 600. In order to achieve the required sensitivity of the Michelson interferometer, the axes of interfering beams have to be superimposed with a residual angle of the order 10 -8 rad. The beam spots have to be centred on the mirrors to minimize coupling of alignment noise into longitudinal signals. We present the actual control topology and results from the system in operation, which controls all alignment degrees of the power-recycled Michelson. With this system continuous lock stretches of more than 121 h duration were achieved

  1. Control rod housing alignment apparatus

    International Nuclear Information System (INIS)

    Dixon, R.C.; Deaver, G.A.; Punches, J.R.; Singleton, G.E.; Erbes, J.G.; Offer, H.P.

    1991-01-01

    This paper discusses an alignment device for precisely locating the position of the top of a control rod drive housing from an overlying and corresponding hole and alignment pin in a core plate within a boiling water nuclear reactor. It includes a shaft, the shaft having a length sufficient to extend from the vicinity of the top of the control rod drive housing up to and through the hole in the core plate; means for registering the top of the shaft to the hole in the core plate, the registering means including means for registering with an alignment pin in the core plate adjacent the hole

  2. Prediction of molecular alignment of nucleic acids in aligned media

    International Nuclear Information System (INIS)

    Wu Bin; Petersen, Michael; Girard, Frederic; Tessari, Marco; Wijmenga, Sybren S.

    2006-01-01

    We demonstrate - using the data base of all deposited DNA and RNA structures aligned in Pf1-medium and RDC refined - that for nucleic acids in a Pf1-medium the electrostatic alignment tensor can be predicted reliably and accurately via a simple and fast calculation based on the gyration tensor spanned out by the phosphodiester atoms. The rhombicity is well predicted over its full range from 0 to 0.66, while the alignment tensor orientation is predicted correctly for rhombicities up to ca. 0.4, for larger rhombicities it appears to deviate somewhat more than expected based on structural noise and measurement error. This simple analytical approach is based on the Debye-Huckel approximation for the electrostatic interaction potential, valid at distances sufficiently far away from a poly-ionic charged surface, a condition naturally enforced when the charge of alignment medium and solute are of equal sign, as for nucleic acids in a Pf1-phage medium. For the usual salt strengths and nucleic acid sizes, the Debye-Huckel screening length is smaller than the nucleic acid size, but large enough for the collective of Debye-Huckel spheres to encompass the whole molecule. The molecular alignment is then purely electrostatic, but it's functional form is under these conditions similar to that for steric alignment. The proposed analytical expression allows for very fast calculation of the alignment tensor and hence RDCs from the conformation of the nucleic acid molecule. This information provides opportunities for improved structure determination of nucleic acids, including better assessment of dynamics in (multi-domain) nucleic acids and the possibility to incorporate alignment tensor prediction from shape directly into the structure calculation process. The procedures are incorporated into MATLAB scripts, which are available on request

  3. Dynamic knee alignment and collateral knee laxity and its variations in normal humans

    Directory of Open Access Journals (Sweden)

    Kamal eDeep

    2015-11-01

    Full Text Available Alignment of normal, arthritic and replaced human knees is a much debated subject as is the collateral ligamentous laxity. Traditional quantitative values have been challenged. Methods used to measure these are also not without flaws. Authors review the recent literature and a novel method of measurement of these values has been included. This method includes use of computer navigation technique in clinic setting for assessment of the normal or affected knee before the surgery. Computer navigation has been known for achievement of alignment accuracy during knee surgery. Now its use in clinic setting has added to the inventory of measurement methods. Authors dispel the common myth of straight mechanical axis in normal knees and also look at quantification of amount of collateral knee laxity. Based on the scientific studies it has been shown that the mean alignment is in varus in normal knees. It changes from lying non weight bearing position to standing weight bearing position in both coronal and the sagittal planes. It also varies with gender and race. The collateral laxity is also different for males and females. Further studies are needed to define the ideal alignment and collateral laxity which the surgeon should aim for individual knees.

  4. Sagittal reconstruction computed tomography in metrizamide cisternography. Useful diagnostic procedure for malformations in craniovertebral junction and posterior fossa

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, H.; Okita, N.; Fujii, T.; Yoshioka, M.; Saito, H. (Tohoku Univ., Sendai (Japan). School of Medicine)

    1982-08-01

    We studied the sagittal reconstruction technique in computed tomography with metrizamide. Ten ml of metrizamide, 170 mg iodine/ml in concentration, were injected by lumbar puncture. After diffusion of the injected metrizamide, axial computed tomograms were taken by thin slice width (5 mm) with overlapped technique. Then electrical sagittal reconstruction was carried out by optioned software. Injection of metrizamide, non-ionic water soluble contrast media, made clear contrasts among bone, brain parenchyma and cerebrospinal fluid with computed tomography. Sagittal reconstruction technique could reveal more precise details and accurate anatomical relations than ordinary axial computed tomography. This technique was applied on 3 cases (Arnold-Chiari malformation, large cisterna magna and partial agenesis cerebellar vermis), which demonstrated a useful diagnostic procedure for abnormalities of craniovertebral junction and posterior fossa. The adverse reactions of metrizamide were negligible in our series.

  5. Evaluation of uterine peristalsis using cine MRI on the coronal plane in comparison with the sagittal plane.

    Science.gov (United States)

    Shitano, Fuki; Kido, Aki; Kataoka, Masako; Fujimoto, Koji; Kiguchi, Kayo; Fushimi, Yasutaka; Togashi, Kaori

    2016-01-01

    Uterine peristalsis is supposed to be closely related to the early stages of reproduction. Sperms are preferentially transported from the uterine cervix to the side of the tube with the dominant follicle. However, with respect to magnetic resonance imaging (MRI), uterine peristalsis has only been evaluated at the sagittal plane of cine MRI. To evaluate and compare uterine peristalsis both on sagittal and coronal planes using cine MRI. Internal ethics committee approval was obtained, and subjects provided informed written consent. Thirty-one women underwent MRI scans in the periovulatory phase of the menstrual cycle. Cine MR images obtained by fast advanced spin echo sequence at 3-T field strength magnet (Toshiba Medical Systems) were visually evaluated by two independent radiologists. The frequency and the direction of peristalsis, and the presence of outer myometrium conduction of signal intensities (OMC), were evaluated. The laterality of the dominant follicle was determined on axial images and compared with the peristaltic direction in fundus. The subjects in which peristaltic directions were more clearly recognized were significantly frequent in coronal planes than in sagittal planes (P < 0.05). There was no significant difference in the peristaltic frequency between the sagittal and the coronal plane. However, the OMC was more recognized in the coronal plane than in the sagittal plane (P < 0.05). Peristaltic waves conducted toward the possible ovulation side were observed in only three of the 10 subjects. OMC of uterine peristalsis was better demonstrated in the coronal plane compared to the sagittal plane. © The Foundation Acta Radiologica 2015.

  6. A new quasi-invariant parameter characterizing the postural alignment of young asymptomatic adults.

    Science.gov (United States)

    Amabile, Celia; Pillet, Hélène; Lafage, Virginie; Barrey, Cédric; Vital, Jean-Marc; Skalli, Wafa

    2016-11-01

    Our study aims to describe the postural alignment of young asymptomatic subjects from head to feet from bi-planar standing full-body X-rays, providing database to compare to aging adults. Novelty resides in the inclusion of the head and lower limbs in the erected posture's analysis. For 69 young asymptomatic subjects (18-40 years old) 3D reconstructions of the head, spine, pelvis and lower limbs segments were performed from bi-planar full-body X-rays. Usual studied spinal, pelvic and lower limbs' parameters were computed in 3D, sagittal and frontal planes of the patient. Relationships between these parameters were investigated. Inclinations of different lines were studied to characterize the erected posture. Values found for spinal curvatures, pelvic parameters and lower limbs geometrical parameters agreed with the literature: thoracic kyphosis, lumbar lordosis, pelvic incidence, pelvic tilt and sagittal vertical axis were respectively in average of 26.9° (SD 7.2°), 30.5° (SD 7.5°), 51.0° (SD 9.4°), 11.1° (SD 5.6°) and -8.9 mm (SD 21.6 mm). The angle between the vertical and the line joining the most superior point of dentiform apophyse of C2 (OD) and the center of the bi-coxofemoral axis (HA) was the less variable one (SD 1.6°). This study on 3D postural alignment reports the geometry of the spine, pelvis and lower limbs, of the young asymptomatic adult. The less variable angle is the one of the line OD-HA with the vertical, highlighting the vertical alignment of the head above the pelvis. This study provides a basis for future comparisons when investigating aging populations.

  7. The Rigors of Aligning Performance

    Science.gov (United States)

    2015-06-01

    17 G. STRATEGIC MANAGEMENT IN PUBLIC ORGANIZATIONS ..........18 H. LITERATURE...67 A. SWOT ANALYSIS ........................................................................................67 1. Strengths...alignment. Finally, a Strengths, Weaknesses, Opportunities, and Threats ( SWOT ) analysis is conducted to identify potential areas for improvement within

  8. Fixture for aligning motor assembly

    Science.gov (United States)

    Shervington, Roger M.; Vaghani, Vallabh V.; Vanek, Laurence D.; Christensen, Scott A.

    2009-12-08

    An alignment fixture includes a rotor fixture, a stator fixture and a sensor system which measures a rotational displacement therebetween. The fixture precisely measures rotation of a generator stator assembly away from a NULL position referenced by a unique reference spline on the rotor shaft. By providing an adjustable location of the stator assembly within the housing, the magnetic axes within each generator shall be aligned to a predetermined and controlled tolerance between the generator interface mounting pin and the reference spline on the rotor shaft. Once magnetically aligned, each generator is essentially a line replaceable unit which may be readily mounted to any input of a multi-generator gearbox assembly with the assurance that the magnetic alignment will be within a predetermined tolerance.

  9. Antares automatic beam alignment system

    International Nuclear Information System (INIS)

    Appert, Q.; Swann, T.; Sweatt, W.; Saxman, A.

    1980-01-01

    Antares is a 24-beam-line CO 2 laser system for controlled fusion research, under construction at Los Alamos Scientific Laboratory (LASL). Rapid automatic alignment of this system is required prior to each experiment shot. The alignment requirements, operational constraints, and a developed prototype system are discussed. A visible-wavelength alignment technique is employed that uses a telescope/TV system to view point light sources appropriately located down the beamline. Auto-alignment is accomplished by means of a video centroid tracker, which determines the off-axis error of the point sources. The error is nulled by computer-driven, movable mirrors in a closed-loop system. The light sources are fiber-optic terminations located at key points in the optics path, primarily at the center of large copper mirrors, and remotely illuminated to reduce heating effects

  10. Aligning with new Digital Strategy

    DEFF Research Database (Denmark)

    Yeow, Adrian; Soh, Christina; Hansen, Rina

    2018-01-01

    Prior IS research has not fully addressed the aligning process in the highly dynamic context of digital strategy. To address this gap, we conduct a longitudinal analysis of a B2B company's journey to enact its B2C digital strategy, using the dynamic capabilities approach. We found...... that as an organization shifts towards a digital strategy, misalignments between the emergent strategy and resources give rise to tension. Our study resulted in the development of an aligning process model that is comprised of three phases (exploratory, building, and extending) and generalizable organizational aligning...... actions that form the organization's sensing, seizing, and transforming capacities. These aligning actions iteratively reconfigured organizational resources and refined strategy in order to respond to both changes in the environment and internal tensions. We also recognized that there are challenges...

  11. Long-term stability of anterior open-bite closure with bilateral sagittal split osteotomy.

    Science.gov (United States)

    Fontes, Adelina M; Joondeph, Donald R; Bloomquist, Dale S; Greenlee, Geoffrey M; Wallen, Terry R; Huang, Greg J

    2012-12-01

    Maxillary impaction and bimaxillary osteotomies are used to treat anterior open-bite malocclusions but can have adverse soft-tissue effects. Correcting an anterior open bite with a single mandibular procedure avoids these undesirable soft-tissue effects, but the stability of this procedure is unknown. The purpose of this study was to assess the long-term stability of anterior open-bite correction with bilateral sagittal split osteotomy and rigid internal fixation. Orthognathic surgical records of 1 oral surgeon were searched for all patients treated for anterior open bite with bilateral sagittal split osteotomy and surgical closing rotation of the mandible with rigid internal fixation. Cephalometric films from initial consultation, presurgery, postsurgery, orthodontic appliance removal, and a mean of 4.5 years after orthodontic appliance removal were collected, traced, and measured. Thirty-one patients fit the inclusion criteria for this study and had an initial mean open bite of -2.6 mm (SD, 1.1 mm). The patients experienced an average mandibular closing rotation of 3.7° (SD, 2.4°) with surgery. By orthodontic appliance removal, the mandible rotated open 1.1°, and incisor overlap was 1.4 mm (SD, 1.0 mm). Approximately 4.5 years after orthodontic appliance removal, the mean incisor overlap was maintained at 1.0 mm (SD, 1.0 mm), yet the mandible rotated open an additional 1.1°. Only 3 patients relapsed to no incisor overlap in the long term, and only 3 patients experienced relapse greater than 1 mm in the long term. Approximately 90% of the treated patients had a positive incisor overlap 4.5 years after orthodontic appliance removal. Despite a 60% loss of mandibular surgical closing rotation, only 10% of the patients relapsed to no incisor overlap in the long term. Bilateral sagittal split osteotomy and surgical closing rotation of the mandible by using rigid internal fixation should be considered a stable alternative in the treatment of mild

  12. Correlation between Sagittal Spinopelvic Parametersand Oswestry Disability Indexafter Thoracal and Lumbar Spine Stabilization and Fusion

    Directory of Open Access Journals (Sweden)

    Yudistira Prama Tirta

    2017-04-01

    Full Text Available Spinopelvic parameter consists of sagittal vertical axis (SVA, pelvic incidence (PI, pelvic tilt (PT, sacral slope (SS which are measured by whole-spine-lateral-view radiograph in standing position. Measurement of the separameters is pivotalas the land mark analysis toachieve correct sagittal balance. The objective of the study is to analyze the correlation between PI, PT, SVA and SSwith theclinical outcomes which was measured usingOswestry Disability Index (ODI scoring system.This is a cross-sectional study involving 19 patients who underwent thoracal and lumbar fusion surgery in our centerduring 2012-2014. Radiographi cevaluation of SVA, PI, PT, and SS and ODI score were performed 1 year after surgery. Pearson test was conducted to determine the correlation between SVA, PI, PT, and SS with ODI score.There wasa strong correlation between ODI withSVA and PI (p<0.001,r=0.866; p=0.006; r=0.603, respectively. There was no correlation between other parameters with ODI.Based on this study, spinopelvic parameters that can represent the clinical outcome after thoracal and lumbar fusion and stabilization surgeries are SVA and PI. Keywords: spinopelvic parameter, post operation, vertebrae fusion.   Korelasi antara Parameter Luaran Spinopelvik Sagital dengan Oswestry Disability Index pasca Stabilisasi dan Fusi Vertebra Torakal dan Lumbar   Abstrak Parameter spinopelvis terdiri atas sagittal vertical axis (SVA, pelvic incidence (PI, pelvic tilt (PT, sacral slope (SS dan diukur menggunakan X-ray seluruh tulang belakang lateral yang diambil pada posisi berdiri. Pengukuran parameter ini penting sebagai dasar analisis keseimbangan sagital pada operasi rekonstruksi vertebra. Tujuan penelitian ini adalah untuk menganalisis korelasi antara PI, PT, SVA, dan SS pada luaran klinis berdasarkan sistem skoring oswestry disability index (ODI. Studi ini adalah studi potong lintang dengan 19 subjek yang menjalani fusi dan stabilisasi torakal dan lumbal di center kami

  13. Chronic low back pain after lumbosacral fracture due to sagittal and frontal vertebral imbalance.

    Science.gov (United States)

    Boyoud-Garnier, L; Boudissa, M; Ruatti, S; Kerschbaumer, G; Grobost, P; Tonetti, J

    2017-06-01

    Over time, some patients with unilateral or bilateral lumbosacral injuries experience chronic low back pain. We studied the sagittal and frontal balance in a population with these injuries to determine whether mismatch in the pelvic and lumbar angles are associated with chronic low back pain. Patients with posterior pelvic ring fractures (Tile C1, C2, C3 and A3.3) that had healed were included. Foreign patients and those with an associated spinal or acetabular fracture or nonunion were excluded. The review consisted of subjective questionnaires, a clinical examination, and standing A/P and lateral stereoradiographic views. The pelvic tilt (PT), sacral slope (SS), pelvic incidence (PI), measured lumbar lordosis (LLm), T9 sagittal offset, leg discrepancy (LD) and lateral curvature (LC). The expected lumbar lordosis (LLe) was calculated using the formula LLe=PI+9°. We defined lumbopelvic mismatch (LPM) as the difference between LLm and LLe being equal or greater than 25% of LLe. Fifteen patients were reviewed after an average follow-up of 8.8 years [5.4-15]. There were four Tile C1, five Tile C2, five Tile C3 and one Tile A3.3 fracture. Ten of the 15 patients had low back pain. The mean angles were: LLm 49.6° and LLe 71.9° (P=0.002), PT 21.3°, SS 44.1°, PI 62.9° in patients with low back pain and LLm 57.4° and LLe 63.2° (P=0.55), PT 13°, SS 43.1°, PI 54.2° in those without. LPM was present in 9 patients, 8 of who had low back pain (P=0.02). Six patients, all of whom had low back pain, had a mean LC of 7.5° [4.5-23] (P=0.02). The mean LD was 0.77cm. The findings of this small study suggest that patients who experience low back pain after their posterior arch of the pelvic ring fracture has healed, have a lumbopelvic mismatch. Early treatment of these patients should aim to reestablish the anatomy of the pelvic base relative to the frontal and sagittal balance. IV. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Agreement between fiber optic and optoelectronic systems for quantifying sagittal plane spinal curvature in sitting.

    Science.gov (United States)

    Cloud, Beth A; Zhao, Kristin D; Breighner, Ryan; Giambini, Hugo; An, Kai-Nan

    2014-07-01

    Spinal posture affects how individuals function from a manual wheelchair. There is a need to directly quantify spinal posture in this population to ultimately improve function. A fiber optic system, comprised of an attached series of sensors, is promising for measuring large regions of the spine in individuals sitting in a wheelchair. The purpose of this study was to determine the agreement between fiber optic and optoelectronic systems for measuring spinal curvature, and describe the range of sagittal plane spinal curvatures in natural sitting. Able-bodied adults (n = 26, 13 male) participated. Each participant assumed three sitting postures: natural, slouched (accentuated kyphosis), and extension (accentuated lordosis) sitting. Fiber optic (ShapeTape) and optoelectronic (Optotrak) systems were applied to the skin over spinous processes from S1 to C7 and used to measure sagittal plane spinal curvature. Regions of kyphosis and lordosis were identified. A Cobb angle-like method was used to quantify lordosis and kyphosis. Generalized linear model and Bland-Altman analyses were used to assess agreement. A strong correlation exists between curvature values obtained with Optotrak and ShapeTape (R(2) = 0.98). The mean difference between Optotrak and ShapeTape for kyphosis in natural, extension, and slouched postures was 4.30° (95% LOA: -3.43 to 12.04°), 3.64° (95% LOA: -1.07 to 8.36°), and 4.02° (95% LOA: -2.80 to 10.84°), respectively. The mean difference for lordosis, when present, in natural and extension postures was 2.86° (95% LOA: -1.18 to 6.90°) and 2.55° (95% LOA: -3.38 to 8.48°), respectively. In natural sitting, the mean ± SD of kyphosis values was 35.07 ± 6.75°. Lordosis was detected in 8/26 participants: 11.72 ± 7.32°. The fiber optic and optoelectronic systems demonstrate acceptable agreement for measuring sagittal plane thoracolumbar spinal curvature. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. BinAligner: a heuristic method to align biological networks.

    Science.gov (United States)

    Yang, Jialiang; Li, Jun; Grünewald, Stefan; Wan, Xiu-Feng

    2013-01-01

    The advances in high throughput omics technologies have made it possible to characterize molecular interactions within and across various species. Alignments and comparison of molecular networks across species will help detect orthologs and conserved functional modules and provide insights on the evolutionary relationships of the compared species. However, such analyses are not trivial due to the complexity of network and high computational cost. Here we develop a mixture of global and local algorithm, BinAligner, for network alignments. Based on the hypotheses that the similarity between two vertices across networks would be context dependent and that the information from the edges and the structures of subnetworks can be more informative than vertices alone, two scoring schema, 1-neighborhood subnetwork and graphlet, were introduced to derive the scoring matrices between networks, besides the commonly used scoring scheme from vertices. Then the alignment problem is formulated as an assignment problem, which is solved by the combinatorial optimization algorithm, such as the Hungarian method. The proposed algorithm was applied and validated in aligning the protein-protein interaction network of Kaposi's sarcoma associated herpesvirus (KSHV) and that of varicella zoster virus (VZV). Interestingly, we identified several putative functional orthologous proteins with similar functions but very low sequence similarity between the two viruses. For example, KSHV open reading frame 56 (ORF56) and VZV ORF55 are helicase-primase subunits with sequence identity 14.6%, and KSHV ORF75 and VZV ORF44 are tegument proteins with sequence identity 15.3%. These functional pairs can not be identified if one restricts the alignment into orthologous protein pairs. In addition, BinAligner identified a conserved pathway between two viruses, which consists of 7 orthologous protein pairs and these proteins are connected by conserved links. This pathway might be crucial for virus packing and

  16. Evaluation of facial morphology and sagittal relationship between dental arches in primary and mixed dentition.

    Science.gov (United States)

    Traldi, Aline; Valdrighi, Heloísa Cristina; de Souza, Luciane Zanin; Vedovello, Silvia Amélia Scudeler

    2015-01-01

    To assess facial morphology (Pattern) and sagittal relationship between dental arches (Class), and establish a potential association between them and the variables sex, age and ethnicity, among schoolchildren aged between 4 and 9 years old (mean age of 6.7 years) in primary and mixed dentitions. The sample comprised 875 children (457 males and 418 females) attending schools in Descalvado, São Paulo, Brazil. An attempt was made with a view to establish a potential association between children's morphological features with sex, age and ethnicity. Descriptive analysis revealed a predominance of facial Pattern I (69.9 %) and Class I (67.4 %). Statistical tests (p dental arches tend to be correlated. Ethnicity was associated with facial pattern, with Pattern I being the most recurrent among Caucasians and facial Pattern II being recurrent among Afro-descendant subjects.

  17. Osteosynthesis techniques used for mandibular sagittal split osteotomy – history of orthognathic procedures and modern practice.

    Science.gov (United States)

    Nowak, Rafał; Trybek, Grzegorz

    Choosing an appropriate fixation technique after maxillary or mandibular osteotomy is one of the key factors affecting the success of orthognathic surgery. In line with the development of new surgical methods and techniques, the surgeons’ approach to the fixation of bone fragments has evolved accordingly, varying from non-fusion to different osteosynthesis techniques. Advances in medical sciences and medical technologies, have changed our attitudes to bone fragment reduction in orthopaedics and traumatology, and also in maxillofacial surgery. The pivotal underlying principle which determines bone healing – that is proper positioning so as to ensure appropriate contact area and immobilisation so as to ensure osteosynthesis – has remained unchanged for centuries. However, over the years, patient comfort and the predictability of treatment outcomes have vastly improved. The paper provides an overview of the techniques and methods used for the fixation of osteotomized fragments after bilateral sagittal split osteotomy since its introduction by Hugo Obwegeser up to the present day.

  18. Association of achondroplasia with sagittal synostosis and scaphocephaly in two patients, an underestimated condition?

    Science.gov (United States)

    Accogli, Andrea; Pacetti, Mattia; Fiaschi, Pietro; Pavanello, Marco; Piatelli, Gianluca; Nuzzi, Daniele; Baldi, Maurizia; Tassano, Elisa; Severino, Maria Savina; Allegri, Anna; Capra, Valeria

    2015-03-01

    We report on two patients with an unusual combination of achondroplasia and surgically treated sagittal synostosis and scaphocephaly. The most common achondroplasia mutation, p.Gly380Arg in fibroblast growth factor receptor 3 (FGFR3), was detected in both patients. Molecular genetic testing of FGFR1, FGFR2, FGFR3 and TWIST1 genes failed to detect any additional mutations. There are several reports of achondroplasia with associated craniosynostosis, but no other cases of scaphocephaly in children with achondroplasia have been described. Recently it has been demonstrated that FGFR3 mutations affect not only endochondral ossification but also membranous ossification, providing new explanations for the craniofacial hallmarks in achondroplasia. Our report suggests that the association of isolated scaphocephaly and other craniosynostoses with achondroplasia may be under recognized. © 2015 Wiley Periodicals, Inc.

  19. Resorbable plate osteosynthesis of sagittal split osteotomies with major bone movement.

    Science.gov (United States)

    Landes, Constantin A; Kriener, Susanne

    2003-05-01

    This study evaluates resorbable miniplate osteosyntheses in sagittal split osteotomies with major bone repositioning. Two resorbable 2.0-mm miniplate systems, MacroSorb (Macropore, San Diego, Calif.) and PolyMax (Synthes, Oberdorf, Switzerland), were compared consecutively. Amorphous 70:30 poly-L/DL-lactide copolymer plates sustain continuous hydrolysis through water penetration into the implant body during the first 6 months in situ. This breaks copolymer chains into smaller particles, which later become degraded through phagocytotic cells. Eighteen patients, 10 women and eight men, 16 to 57 years old (average, 27 years) were examined. They had severe dysgnathia caused by congenital craniofacial malformations, systemic disorders, trauma, amelogenesis imperfecta, oligodontia, and other conditions, and they needed five 8- to 10-mm and 13 major 10- to 12-mm repositions. Twelve sagittal split osteotomies were fixed with 12 MacroSorb plates in six patients, and 24 osteotomies were filled with 32 PolyMax plates in 12 patients. Ten mandibular plate, screw, hard-tissue, and soft-tissue specimens were taken at 3, 6, 9, or 12 months postoperatively in secondary operations (e.g., dental implant placement).Follow-up ranged from 4 to 19 months; all osteosyntheses reossified. Four patients showed proximal fragments rotated up to 5 mm sagittally anteriorly and nonaligned burr holes on the postoperative radiogram, suggesting plate fractures or screw pullout. When plate fracture was noted, guided occlusion was maintained 4 weeks after surgery. Occlusal, radiologic, and skeletal results remained stable. After starting fixation with two plates on each side, no more plate fractures were seen. In three other patients, minor skeletal relapses up to 3 mm horizontally resulted. Local histologic inspection of specimens showed thorough osseous union. Screw remnants embedded in bone made screw pullout unlikely; rather, screw-head or plate fractures were found as multiple degraded particles

  20. Superior Sagittal Sinus Thrombosis Presenting with Hallucinations in the Puerperium: A Case Report

    Directory of Open Access Journals (Sweden)

    Zylfije Hundozi

    2016-12-01

    Full Text Available Cerebral venous sinus thrombosis is an uncommon cause of stroke presenting with varied presentation patterns. We report a case of a 21-year-old woman with superior sagittal sinus (SSS thrombosis (SSST developing after childbirth, presenting with visual hallucinations, severe headache, and tonic-clonic seizures. Time-of-flight magnetic resonance angiography (TOF-MRA demonstrated the presence of thrombus in SSS. She was treated with low molecular weight heparin (LMWH followed by warfarin. She had excellent recovery a few weeks after admission and was regularly followed up. Although this condition can be presented with different neurological symptoms, it does not typically present with hallucinations. We suggest that CSVT should be suspected even when a patient presents with an atypical picture in a category of patients at higher risk.

  1. Moyamoya disease and sagittal sinus thrombosis in a child with Down's syndrome

    International Nuclear Information System (INIS)

    Del-Rio Camacho, G.; Leal Orozco, A.; Camino Lopez, M.; Ruiz-Moreno, M.; Perez-Higueras, A.; Al-Assir, I.

    2001-01-01

    A girl with Down's syndrome, moyamoya disease and sagittal sinus thrombosis is described. She was diagnosed after acute neurological deterioration by MRI and angiography. Recombinant tissue plasminogen activator (r-TPA) was injected locally to recanalise the thrombus. The patient's condition significantly improved and she was discharged. After 2 years of follow-up the child remains asymptomatic. Moyamoya syndrome and cerebral venous thrombosis should not be overlooked as a cause of acute neurological deterioration in a child with Down's syndrome. MRA appears to be a safe and accurate alternative to traditional angiography for the diagnosis of moyamoya disease. Local fibrinolysis with r-TPA is the treatment of choice for cerebral venous thrombosis due to its safety and efficacy. (orig.)

  2. Emergency surgical management of traumatic superior sagittal sinus injury: An unusual case

    Directory of Open Access Journals (Sweden)

    Sudhansu Sekhar Mishra

    2012-01-01

    Full Text Available Head injuries following fall of heavy objects are not very uncommon in developing countries. However, compound depressed skull fracture with superior sagittal sinus (SSS laceration caused by a flying asbestos fragment in a stormy afternoon is an unusual mode of head injury. We report such an unusual case of compound depressed skull fracture by an asbestos fragment injuring the middle third of SSS and its successful surgical management in a 14-year-old child. The role of computed tomography (CT scan of head with 3D reconstruction is highlighted. Early steps taken in this case to check the profuse bleeding, which helped save the life of this boy is interesting to note.

  3. An Experimental Study of Energy-Saving Shoes for Robot as Sagittal Plane Assistance

    Science.gov (United States)

    Minakata, Hideaki; Tadakuma, Susumu

    In this paper, we propose flexible shoe system to apply passive walking manner to ordinary humanoid biped. In this system, 2DOF (FF & FB) control scheme is used and realize walking with less ankle torque. Besides, this system is consisted as reference modification of position control system, so it can be applicable to most of walking robot even if its joint servo is black box. The effectiveness and characteristics of this system is confirmed by computer simulations and experimental result. The softness of shoe is very important parameter for energy consumption and walking stability. From the discussions of the system, it is said that sagittal plane assistance shoes reduce the energy loss due to the ankle joint friction. Finally, we confirmed the reduction of energy consumption on walking experiment, so we call this system as “energy saving shoes.”

  4. Ability of sagittal kinematic variables to estimate ground reaction forces and joint kinetics in running.

    Science.gov (United States)

    Wille, Christa M; Lenhart, Rachel L; Wang, Sijian; Thelen, Darryl G; Heiderscheit, Bryan C

    2014-10-01

    Controlled laboratory study, cross-sectional design. To determine if sagittal kinematic variables can be used to estimate select running kinetics. Excessive loading during running has been implicated in a variety of injuries, yet this information is typically not assessed during a standard clinical examination. Developing a clinically feasible strategy to estimate ground reaction forces and joint kinetics may improve the ability to identify those at an increased risk of injury. Three-dimensional kinematics and ground reaction forces of 45 participants were recorded during treadmill running at self-selected speed. Kinematic variables used to estimate specific kinetic metrics included vertical excursion of the center of mass, foot inclination angle at initial contact, horizontal distance between the center of mass and heel at initial contact, knee flexion angle at initial contact, and peak knee flexion angle during stance. Linear mixed-effects models were fitted to explore the association between the kinetic and kinematic measures, including step rate and sex, with final models created using backward variable selection. Models were developed to estimate peak knee extensor moment (R(2) = 0.43), energy absorbed at the knee during loading response (R(2) = 0.58), peak patellofemoral joint reaction force (R(2) = 0.55), peak vertical ground reaction force (R(2) = 0.48), braking impulse (R(2) = 0.50), and average vertical loading rate (R(2) = 0.04). Our findings suggest that insights into important running kinetics can be obtained from a subset of sagittal plane kinematics common to a clinical running analysis. Of note, the limb posture at initial contact influenced subsequent loading patterns in stance.

  5. Relationship between anthropometric measures and sagittal spinal curvatures in adult male handball players

    Directory of Open Access Journals (Sweden)

    Ameer Mariam Abdul-Moneem

    2017-12-01

    Full Text Available Purpose. Increasing anthropometric measures bring considerable spinal loads during sports practice, which inversely affects the adaptation abilities of the spinal structures; this in turn influences the spinal curvatures. The study was conducted to explore the relationship between anthropometric measures and sagittal spinal curvatures in handball players. Method. The total of 83 male handball players were divided into 2 groups, depending on their body height: group 1 (age, 23.62 ± 2.07 years consisted of 40 handball players with height above average, group 2 (age, 24.63 ± 2.58 years consisted of 43 handball players with height below average. The thoracic and lumbar curvatures and trunk height were measured with the Formetric III 4D spine and posture analysis system. Results. The thoracic kyphosis of group 1 was significantly higher than that of group 2 (p = 0.038, without a significant difference in lumbar lordosis (p = 0.312, and significant difference in the coefficient of compensation between thoracic kyphosis and lumbar lordosis (p = 0.026. Group 1 showed strong positive correlation between body height and kyphotic angle (r = 0.897, and moderate positive correlation with lordosis angle (r = 0.496. In group 2, there was weak positive correlation with kyphotic angle (r = 0.381, and weak negative correlation with lumbar lordosis angle (r = -0.355. Conclusions. Increasing body height of handball players is associated with bigger kyphotic and lordotic angles. Owing to frequent sagittal asymmetric overloading of the spine during handball training, exercises that help maintain good posture and correct the thoracic kyphosis are required, especially for taller players.

  6. A dynamic finite element analysis of human foot complex in the sagittal plane during level walking.

    Directory of Open Access Journals (Sweden)

    Zhihui Qian

    Full Text Available The objective of this study is to develop a computational framework for investigating the dynamic behavior and the internal loading conditions of the human foot complex during locomotion. A subject-specific dynamic finite element model in the sagittal plane was constructed based on anatomical structures segmented from medical CT scan images. Three-dimensional gait measurements were conducted to support and validate the model. Ankle joint forces and moment derived from gait measurements were used to drive the model. Explicit finite element simulations were conducted, covering the entire stance phase from heel-strike impact to toe-off. The predicted ground reaction forces, center of pressure, foot bone motions and plantar surface pressure showed reasonably good agreement with the gait measurement data over most of the stance phase. The prediction discrepancies can be explained by the assumptions and limitations of the model. Our analysis showed that a dynamic FE simulation can improve the prediction accuracy in the peak plantar pressures at some parts of the foot complex by 10%-33% compared to a quasi-static FE simulation. However, to simplify the costly explicit FE simulation, the proposed model is confined only to the sagittal plane and has a simplified representation of foot structure. The dynamic finite element foot model proposed in this study would provide a useful tool for future extension to a fully muscle-driven dynamic three-dimensional model with detailed representation of all major anatomical structures, in order to investigate the structural dynamics of the human foot musculoskeletal system during normal or even pathological functioning.

  7. A dynamic finite element analysis of human foot complex in the sagittal plane during level walking.

    Science.gov (United States)

    Qian, Zhihui; Ren, Lei; Ding, Yun; Hutchinson, John R; Ren, Luquan

    2013-01-01

    The objective of this study is to develop a computational framework for investigating the dynamic behavior and the internal loading conditions of the human foot complex during locomotion. A subject-specific dynamic finite element model in the sagittal plane was constructed based on anatomical structures segmented from medical CT scan images. Three-dimensional gait measurements were conducted to support and validate the model. Ankle joint forces and moment derived from gait measurements were used to drive the model. Explicit finite element simulations were conducted, covering the entire stance phase from heel-strike impact to toe-off. The predicted ground reaction forces, center of pressure, foot bone motions and plantar surface pressure showed reasonably good agreement with the gait measurement data over most of the stance phase. The prediction discrepancies can be explained by the assumptions and limitations of the model. Our analysis showed that a dynamic FE simulation can improve the prediction accuracy in the peak plantar pressures at some parts of the foot complex by 10%-33% compared to a quasi-static FE simulation. However, to simplify the costly explicit FE simulation, the proposed model is confined only to the sagittal plane and has a simplified representation of foot structure. The dynamic finite element foot model proposed in this study would provide a useful tool for future extension to a fully muscle-driven dynamic three-dimensional model with detailed representation of all major anatomical structures, in order to investigate the structural dynamics of the human foot musculoskeletal system during normal or even pathological functioning.

  8. Male and female runners demonstrate different sagittal plane mechanics as a function of static hamstring flexibility

    Science.gov (United States)

    Williams III, D. S. Blaise; Welch, Lee M.

    2015-01-01

    ABSTRACT Background: Injuries to runners are common. However, there are many potential contributing factors to injury. While lack of flexibility alone is commonly related to injury, there are clear differences in hamstring flexibility between males and females. Objective: To compare the effect of static hamstring length on sagittal plane mechanics between male and female runners. Method: Forty subjects (30.0±6.4 years) participated and were placed in one of 4 groups: flexible males (n=10), inflexible males (n=10), flexible females (n=10), and inflexible females (n=10). All subjects were free of injury at the time of data collection. Three-dimensional kinematics and kinetics were collected while subjects ran over ground across 2 force platforms. Sagittal plane joint angles and moments were calculated at the knee and hip and compared with a 2-way (sex X flexibility) ANOVA (α=0.05). Results: Males exhibited greater peak knee extension moment than females (M=2.80±0.47, F=2.48±0.52 Nm/kg*m, p=0.05) and inflexible runners exhibited greater peak knee extension moment than flexible runners (In=2.83±0.56, Fl=2.44±0.51 Nm/kg*m, p=0.01). For hip flexion at initial contact, a significant interaction existed (pHamstring flexibility results in different mechanical profiles in males and females. Flexibility in the hamstrings may result in decreased moments via active or passive tension. These differences may have implications for performance and injury in flexible female runners. PMID:26537812

  9. Maxillomandibular Advancement in Obstructive Sleep Apnea Syndrome Patients: a Restrospective Study on the Sagittal Cephalometric Variables

    Directory of Open Access Journals (Sweden)

    Paolo Ronchi

    2013-06-01

    Full Text Available Objectives: The present retrospective study analyzes sagittal cephalometric changes in patients affected by obstructive sleep apnea syndrome submitted to maxillomandubular advancement. Material and Methods: 15 adult sleep apnea syndrome (OSAS patients diagnosed by polysomnography (PSG and treated with maxillomandubular advancement (MMA were included in this study. Pre- (T1 and postsurgical (T2 PSG studies assessing the apnea/hypopnea index (AHI and the lowest oxygen saturation (LSAT level were compared. Lateral cephalometric radiographs at T1 and T2 measuring sagittal cephalometric variables (SNA, SNB, and ANB were analyzed, as were the amount of maxillary and mandibular advancement (Co-A and Co-Pog, the distance from the mandibular plane to the most anterior point of the hyoid bone (Mp-H, and the posterior airway space (PAS.Results: Postoperatively, the overall mean AHI dropped from 58.7 ± 16 to 8.1 ± 7.8 events per hour (P < 0.001. The mean preoperative LSAT increased from 71% preoperatively to 90% after surgery (P < 0.001. All the patients in our study were successfully treated (AHI < 20 or reduced by 50%. Cephalometric analysis performed after surgery showed a statistically significant correlation between the mean SNA variation and the decrease in the AHI (P = 0.01. The overall mean SNA increase was 6°.Conclusions: Our findings suggest that the improvement observed in the respiratory symptoms, namely the apnea/hypopnea episodes, is correlated with the SNA increase after surgery. This finding may help maxillofacial surgeons to establish selective criteria for the surgical approach to sleep apnea syndrome patients.

  10. Male and female runners demonstrate different sagittal plane mechanics as a function of static hamstring flexibility.

    Science.gov (United States)

    Williams, D S Blaise; Welch, Lee M

    2015-01-01

    Injuries to runners are common. However, there are many potential contributing factors to injury. While lack of flexibility alone is commonly related to injury, there are clear differences in hamstring flexibility between males and females. To compare the effect of static hamstring length on sagittal plane mechanics between male and female runners. Forty subjects (30.0±6.4 years) participated and were placed in one of 4 groups: flexible males (n=10), inflexible males (n=10), flexible females (n=10), and inflexible females (n=10). All subjects were free of injury at the time of data collection. Three-dimensional kinematics and kinetics were collected while subjects ran over ground across 2 force platforms. Sagittal plane joint angles and moments were calculated at the knee and hip and compared with a 2-way (sex X flexibility) ANOVA (α=0.05). Males exhibited greater peak knee extension moment than females (M=2.80±0.47, F=2.48±0.52 Nm/kg*m, p=0.05) and inflexible runners exhibited greater peak knee extension moment than flexible runners (In=2.83±0.56, Fl=2.44±0.51 Nm/kg*m, p=0.01). For hip flexion at initial contact, a significant interaction existed (pFlexible females (36.7±7.4º) exhibited more hip flexion than inflexible females (27.9±4.6º, pflexible males (30.1±9.5º, pflexibility results in different mechanical profiles in males and females. Flexibility in the hamstrings may result in decreased moments via active or passive tension. These differences may have implications for performance and injury in flexible female runners.

  11. Association between preoperative cervical sagittal deformity and inferior outcomes at 2-year follow-up in patients with adult thoracolumbar deformity: analysis of 182 patients.

    Science.gov (United States)

    Scheer, Justin K; Passias, Peter G; Sorocean, Alexandra M; Boniello, Anthony J; Mundis, Gregory M; Klineberg, Eric; Kim, Han Jo; Protopsaltis, Themistocles S; Gupta, Munish; Bess, Shay; Shaffrey, Christopher I; Schwab, Frank; Lafage, Virginie; Smith, Justin S; Ames, Christopher P

    2016-01-01

    .08-0.53), and SRS-22 Appearance 0.34 (0.12-0.94). Preoperative CK did not have an effect on outcomes. Interestingly, despite correction of the thoracolumbar deformity, 53.3% and 51.4% of patients had persistent CPSM and persistent CK, respectively. Patients with thoracolumbar deformity without preoperative CD are likely to have greater improvements in HRQOL after surgery than patients with concomitant preoperative CD. Cervical positive sagittal alignment in adult patients with thoracolumbar deformity is strongly associated with inferior outcomes and failure to reach MCID at 2-year follow-up despite having similar baseline HRQOL to patients without CD. This was the first study to assess the impact of concomitant preoperative cervical malalignment in adult patients with thoracolumbar deformity. These results can help surgeons educate patients at risk for inferior outcomes and direct future research to identify an etiology and improve patient outcomes. Investigation into the etiology of the baseline cervical malalignment may be warranted in patients who present with thoracolumbar deformity.

  12. Nanoscratch technique for aligning multiwalled carbon nanotubes ...

    Indian Academy of Sciences (India)

    to align a MWCNT, as well as the energy required to align a gram of nanotubes, has been estimated. The method demonstrated represents an economical approach for large-scale synthesis of aligned MWCNTs at low costs. Keywords. Carbon nanotube; arc discharge; characterization; alignment; nanoscratch. 1.

  13. Alignment Analyses in the Varus Osteoarthritic Knee Using Computer Navigation.

    Science.gov (United States)

    Tan, Kelvin G; Sathappan, Sathappan S; Teo, Yee Hong; Low, Wilson C J

    2015-06-01

    Osteoarthritic (OA) knees with severe extension varus deformity seem to have correspondingly more severe flexion varus, especially beyond a certain tibiofemoral angle. Clinical measurement of flexion varus and fixed flexion deformity (FFD), which had been difficult to perform because of the spatial alignment of the knee in flexion, was recently made possible with computer navigation. We conducted a study to evaluate the relationship of extension and flexion varus in OA knees and to determine whether severity of FFD in the sagittal plane correlates with severity of coronal plane varus deformity. The study included 317 consecutive cases of computer-navigated total knee arthroplasty performed on OA knees with varus deformities. Three sets of values were extracted from the navigation data: varus angle at maximal knee extension, 90° knee flexion, and maximal knee extension. Correlation analyses were performed for extension and flexion varus, FFD, and coronal plane deformity. OA knees with extension varus of more than 10° had an incremental likelihood of more severe flexion varus. When the extension varus angle exceeded 20°, probability became almost certainty. There was no correlation between FFD and coronal plane varus deformity.

  14. Skeletal Stability after Large Mandibular Advancement (> 10 mm) with Bilateral Sagittal Split Osteotomy and Skeletal Elastic Intermaxillary Fixation

    DEFF Research Database (Denmark)

    Schwartz, Kristoffer; Rodrigo, Maria; Jensen, Thomas

    2016-01-01

    OBJECTIVES: The aim of the present study was to assess the skeletal stability after large mandibular advancement (> 10 mm) with bilateral sagittal split osteotomy and skeletal elastic intermaxillary fixation and to correlate the skeletal stability with the vertical facial type. MATERIAL AND METHO...

  15. Significance of sagittal reformations in routine thoracic and abdominal multislice CT studies for detecting osteoporotic fractures and other spine abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Dirk; Bauer, Jan S.; Zeile, Martin; Rummeny, Ernst J. [Klinikum Rechts der Isar, TU Muenchen, Department of Radiology, Muenchen (Germany); Link, Thomas M. [Musculoskeletal and Quantitative Imaging Research, UCSF, Department of Radiology, San Francisco, CA (United States)

    2008-08-15

    The purpose was to assess osteoporotic vertebral fractures and other spinal lesions in sagittal reformations obtained from routine multidetector computed tomography (MDCT) studies of the thorax and abdomen, to compare sagittal reformations with axial images in detecting these lesions and to investigate how frequently they were missed in the official radiology report. Routine abdominal or thoracoabdominal MDCT using a standard protocol was performed in 112 postmenopausal women. Axial images and sagittal reformations were analyzed separately by two radiologists in consensus and were compared in order to evaluate how often spinal lesions could be detected. In addition the official radiology reports were assessed to determine how many of those abnormalities were identified. Spine abnormalities were visualized in 101/112 postmenopausal women. In 27 patients osteoporotic vertebral deformities were found; 6 of these were shown in the axial images, but none of these were diagnosed in the official radiology report. Additional abnormalities included degenerative disc disease, osteoarthritis of the facet joints, scoliosis, hemangiomas and bone metastases. In only 9/101 patients spine abnormalities were mentioned in the radiology report. Sagittal reformations of standard MDCT images provide important additional information on spinal abnormalities; in particular, osteoporotic vertebral deformities are substantially better detected. (orig.)

  16. Strategic Alignment and New Product Development

    DEFF Research Database (Denmark)

    Acur, Nuran; Kandemir, Destan; Boer, Harry

    2012-01-01

    of NPD performance indicators. Strategic planning and innovativeness appear to affect technological, market, and NPD-marketing alignment positively. Environmental munificence is negatively associated with NPD-marketing alignment, but has no effect on the two other forms of alignment. Technological change......Strategic alignment is widely accepted as a prerequisite for a firm’s success, but insight into the role of alignment in, and its impact on, the new product evelopment (NPD) process and its performance is less well developed. Most publications on this topic either focus on one form of alignment...... has a positive effect on technological alignment, a negative effect on NPD-marketing alignment, but no effect on market alignment. These findings suggest that internal capabilities are more likely to be associated with the development of strategic alignment than environmental factors are. Furthermore...

  17. DIDA: Distributed Indexing Dispatched Alignment.

    Directory of Open Access Journals (Sweden)

    Hamid Mohamadi

    Full Text Available One essential application in bioinformatics that is affected by the high-throughput sequencing data deluge is the sequence alignment problem, where nucleotide or amino acid sequences are queried against targets to find regions of close similarity. When queries are too many and/or targets are too large, the alignment process becomes computationally challenging. This is usually addressed by preprocessing techniques, where the queries and/or targets are indexed for easy access while searching for matches. When the target is static, such as in an established reference genome, the cost of indexing is amortized by reusing the generated index. However, when the targets are non-static, such as contigs in the intermediate steps of a de novo assembly process, a new index must be computed for each run. To address such scalability problems, we present DIDA, a novel framework that distributes the indexing and alignment tasks into smaller subtasks over a cluster of compute nodes. It provides a workflow beyond the common practice of embarrassingly parallel implementations. DIDA is a cost-effective, scalable and modular framework for the sequence alignment problem in terms of memory usage and runtime. It can be employed in large-scale alignments to draft genomes and intermediate stages of de novo assembly runs. The DIDA source code, sample files and user manual are available through http://www.bcgsc.ca/platform/bioinfo/software/dida. The software is released under the British Columbia Cancer Agency License (BCCA, and is free for academic use.

  18. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok [Dept. of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Park, Joong Shin; Jun, Jong Kwan [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    2017-01-15

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP.

  19. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    International Nuclear Information System (INIS)

    Lee, Myoung Seok; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup; Park, Joong Shin; Jun, Jong Kwan

    2017-01-01

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP

  20. Comparison Between Interactive Closest Point and Procrustes Analysis for Determining the Median Sagittal Plane of Three-Dimensional Facial Data.

    Science.gov (United States)

    Xiong, Yuxue; Zhao, Yijiao; Yang, Huifang; Sun, Yucun; Wang, Yong

    2016-03-01

    To compare 2 digital methods to determine median sagittal plane of three-dimensional facial data-the interactive closest point algorithm and Procrustes analysis. The three-dimensional facial data of the 30 volunteers were got by the Face Scan 3D optical sensor (3D-Shape GmbH, Erlangen, Germany), and then were input to the reverse engineering software Imageware 13.0 (Siemens, Plano, TX) and Geomagic 2012 (Cary, NC). Their mirrored data were acquired and superimposed with the original data by the methods of interactive closest points and Procrustes analysis. The median sagittal planes of the 2 methods were extracted from the original and mirrored facial data respectively, 3 asymmetry indices were measured for comparison. Differences between the facial asymmetry indices of the 2 methods were evaluated using the paired sample t-test. In terms of the 3 asymmetry indices, there were no significant differences between interactive closest points and Procrustes analysis for extracting median sagittal plane from three-dimensional facial data.(t = 0.0.060, P = 0.953 for asymmetry index (AI) 1, t = -0.926, P = 0.362 for AI 2, t = 1.1172, P = 0.0.251 for AI 3). In this evaluation of 30 subjects, the Procrustes analysis and the interactive closest point median-sagittal planes were similar in terms of the 3 asymmetry indices. Thus, Procrustes analysis and interactive closest point can both be used to abstract median sagittal plane from three-dimensional facial data.

  1. Laser shaft alignment measurement model

    Science.gov (United States)

    Mo, Chang-tao; Chen, Changzheng; Hou, Xiang-lin; Zhang, Guoyu

    2007-12-01

    Laser beam's track which is on photosensitive surface of the a receiver will be closed curve, when driving shaft and the driven shaft rotate with same angular velocity and rotation direction. The coordinate of arbitrary point which is on the curve is decided by the relative position of two shafts. Basing on the viewpoint, a mathematic model of laser alignment is set up. By using a data acquisition system and a data processing model of laser alignment meter with single laser beam and a detector, and basing on the installation parameter of computer, the state parameter between two shafts can be obtained by more complicated calculation and correction. The correcting data of the four under chassis of the adjusted apparatus moving on the level and the vertical plane can be calculated. This will instruct us to move the apparatus to align the shafts.

  2. Adaptive Processing for Sequence Alignment

    KAUST Repository

    Zidan, Mohammed A.

    2012-01-26

    Disclosed are various embodiments for adaptive processing for sequence alignment. In one embodiment, among others, a method includes obtaining a query sequence and a plurality of database sequences. A first portion of the plurality of database sequences is distributed to a central processing unit (CPU) and a second portion of the plurality of database sequences is distributed to a graphical processing unit (GPU) based upon a predetermined splitting ratio associated with the plurality of database sequences, where the database sequences of the first portion are shorter than the database sequences of the second portion. A first alignment score for the query sequence is determined with the CPU based upon the first portion of the plurality of database sequences and a second alignment score for the query sequence is determined with the GPU based upon the second portion of the plurality of database sequences.

  3. Improving pairwise sequence alignment accuracy using near-optimal protein sequence alignments

    Directory of Open Access Journals (Sweden)

    Bass Ellen J

    2010-03-01

    Full Text Available Abstract Background While the pairwise alignments produced by sequence similarity searches are a powerful tool for identifying homologous proteins - proteins that share a common ancestor and a similar structure; pairwise sequence alignments often fail to represent accurately the structural alignments inferred from three-dimensional coordinates. Since sequence alignment algorithms produce optimal alignments, the best structural alignments must reflect suboptimal sequence alignment scores. Thus, we have examined a range of suboptimal sequence alignments and a range of scoring parameters to understand better which sequence alignments are likely to be more structurally accurate. Results We compared near-optimal protein sequence alignments produced by the Zuker algorithm and a set of probabilistic alignments produced by the probA program with structural alignments produced by four different structure alignment algorithms. There is significant overlap between the solution spaces of structural alignments and both the near-optimal sequence alignments produced by commonly used scoring parameters for sequences that share significant sequence similarity (E-values -5 and the ensemble of probA alignments. We constructed a logistic regression model incorporating three input variables derived from sets of near-optimal alignments: robustness, edge frequency, and maximum bits-per-position. A ROC analysis shows that this model more accurately classifies amino acid pairs (edges in the alignment path graph according to the likelihood of appearance in structural alignments than the robustness score alone. We investigated various trimming protocols for removing incorrect edges from the optimal sequence alignment; the most effective protocol is to remove matches from the semi-global optimal alignment that are outside the boundaries of the local alignment, although trimming according to the model-generated probabilities achieves a similar level of improvement. The

  4. Simultaneous functional and fixed appliance therapy for growth modification and dental alignment prior to prosthetic habilitation in hypohidrotic ectodermal dysplasia: a clinical report.

    Science.gov (United States)

    Suri, Sunjay; Carmichael, Robert P; Tompson, Bryan D

    2004-11-01

    This clinical report describes the simultaneous use of functional and fixed appliances to modify the pattern of dentofacial development and align teeth in preparation for prosthodontic habilitation of a growing child with hypohidrotic ectodermal dysplasia. The treatment objective was to create a more favorable starting point for the prosthodontic phase of habilitation by improving the sagittal and vertical skeletal relationships and facial esthetics. This was accomplished through growth modification with functional appliances conducted simultaneously with eruption of maxillary and mandibular molars, dental arch expansion, alignment, and space management using fixed orthodontic appliances. Orthodontic retention was accomplished by means of removable partial dentures. A second phase of orthodontics conducted closer to the age of skeletal maturation will aim at definitive tooth alignment in preparation for dental implant-supported restorations.

  5. Measurements of magnetic field alignment

    International Nuclear Information System (INIS)

    Kuchnir, M.; Schmidt, E.E.

    1987-01-01

    The procedure for installing Superconducting Super Collider (SSC) dipoles in their respective cryostats involves aligning the average direction of their field with the vertical to an accuracy of 0.5 mrad. The equipment developed for carrying on these measurements is described and the measurements performed on the first few prototypes SSC magnets are presented. The field angle as a function of position in these 16.6 m long magnets is a characteristic of the individual magnet with possible feedback information to its manufacturing procedure. A comparison of this vertical alignment characteristic with a magnetic field intensity (by NMR) characteristic for one of the prototypes is also presented. 5 refs., 7 figs

  6. Replacing fuel alignment in Germany

    International Nuclear Information System (INIS)

    Poetz, F.; Kalthoff, W.

    1991-01-01

    Up to the end of 1989 varying numbers of broken fuel alignment pins were detected in several German PWRs (80 broken pins in all). The distribution of these broken pins over the core cross-section was more or less random. The problem was due to the stress corrosion cracking of the pin material and was restricted to individual pins. It was concluded that all fuel alignment pins made of Inconel X-750 should be replaced. The development of a new pin, more resistant to intergranular stress corrosion, and the replacement technique are outlined. (author)

  7. XUV ionization of aligned molecules

    Energy Technology Data Exchange (ETDEWEB)

    Kelkensberg, F.; Siu, W.; Gademann, G. [FOM Institute AMOLF, Science Park 104, NL-1098 XG Amsterdam (Netherlands); Rouzee, A.; Vrakking, M. J. J. [FOM Institute AMOLF, Science Park 104, NL-1098 XG Amsterdam (Netherlands); Max-Born-Institut, Max-Born Strasse 2A, D-12489 Berlin (Germany); Johnsson, P. [FOM Institute AMOLF, Science Park 104, NL-1098 XG Amsterdam (Netherlands); Department of Physics, Lund University, Post Office Box 118, SE-221 00 Lund (Sweden); Lucchini, M. [Department of Physics, Politecnico di Milano, Istituto di Fotonica e Nanotecnologie CNR-IFN, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Lucchese, R. R. [Department of Chemistry, Texas A and M University, College Station, Texas 77843-3255 (United States)

    2011-11-15

    New extreme-ultraviolet (XUV) light sources such as high-order-harmonic generation (HHG) and free-electron lasers (FELs), combined with laser-induced alignment techniques, enable novel methods for making molecular movies based on measuring molecular frame photoelectron angular distributions. Experiments are presented where CO{sub 2} molecules were impulsively aligned using a near-infrared laser and ionized using femtosecond XUV pulses obtained by HHG. Measured electron angular distributions reveal contributions from four orbitals and the onset of the influence of the molecular structure.

  8. Position list word aligned hybrid

    DEFF Research Database (Denmark)

    Deliege, Francois; Pedersen, Torben Bach

    2010-01-01

    of storage space. This paper presents the Position List Word Aligned Hybrid (PLWAH) compression scheme that improves significantly over WAH compression by better utilizing the available bits and new CPU instructions. For typical bit distributions, PLWAH compressed bitmaps are often half the size of WAH......Compressed bitmap indexes are increasingly used for efficiently querying very large and complex databases. The Word Aligned Hybrid (WAH) bitmap compression scheme is commonly recognized as the most efficient compression scheme in terms of CPU efficiency. However, WAH compressed bitmaps use a lot...

  9. The effect of normalizing the sagittal cervical configuration on dizziness, neck pain, and cervicocephalic kinesthetic sensibility: a 1-year randomized controlled study.

    Science.gov (United States)

    Moustafa, Ibrahim M; Diab, Aliaa A; Harrison, Deed E

    2017-02-01

    Cervicogenic dizziness is a disabling condition commonly associated with cervical dysfunction. Although the growing interest with the importance of normal sagittal configuration of cervical spine, the missing component in the management of cervicogenic dizziness might be altered structural alignment of the cervical spinal region itself. To investigate the immediate and long-term effects of a 1-year multimodal program, with the addition of cervical lordosis restoration and anterior head translation (AHT) correction, on the severity of dizziness, disability, cervicocephalic kinesthetic sensibility, and cervical pain in patients with cervicogenic dizziness. A randomized controlled study with a 1 year and 10 weeks' follow-up. University research laboratory. Seventy-two patients (25 female) between 40 and 55 years with cervicogenic dizziness, a definite hypolordotic cervical spine and AHT posture were randomly assigned to the control or an experimental group. Both groups received the multimodal program; additionally, the experimental group received the Denneroll™ cervical traction. Outcome measures included AHT distance, cervical lordosis, dizziness handicap inventory (DHI), severity of dizziness, dizziness frequency, head repositioning accuracy (HRA) and cervical pain. Measures were assessed at three time intervals: baseline, 10 weeks, and follow-up at 1 year and 10 weeks. Significant group × time effects at both the 10 week post treatment and the 1-year follow-up were identified favoring the experimental group for measures of cervical lordosis (Psensibility, dizziness management outcomes at long-term follow-up. Appropriate physical therapy rehabilitation for cervicogenic dizziness should include structural rehabilitation of the cervical spine (lordosis and head posture correction), as it might to lead greater and longer lasting improved function.

  10. Effect of stretching program in an industrial workplace on hamstring flexibility and sagittal spinal posture of adult women workers: a randomized controlled trial.

    Science.gov (United States)

    Muyor, José M; López-Miñarro, Pedro A; Casimiro, Antonio J

    2012-01-01

    To determine the effect of a stretching program performed in the workplace on the hamstring muscle extensibility and sagittal spinal posture of adult women. Fifty-eight adult women volunteers (mean age of 44.23 ± 8.87 years) from a private fruit and vegetable company were randomly assigned to experimental (n=27) or control (n=31) groups. The experimental group performed three exercises of hamstrings stretching of 20 seconds per exercise, three sessions a week for a period of 12 weeks. The control group did not participate in any hamstring stretching program. Hamstring flexibility was evaluated through the passive straight leg raise test and toe-touch test, performed both before and after the stretching program. Thoracic and lumbar curvatures and pelvic inclination were measured in relaxed standing and toe-touch test with a Spinal Mouse. Significant increases (p < 0.01) in toe-touch score and straight leg raise angle (in both legs) were found in the experimental group during post-test, while the control group showed a non-significant decrease for both toe-touch score and straight leg raise test. A significant decrease in thoracic curve and significant increase in pelvic inclination were found in the toe-touch test for the experimental group (p <0.05). However, no significant changes were found in standing posture for any group. Hamstring stretching exercises performed in the working place are effective for increasing hamstring muscle extensibility. This increase generates a more aligned thoracic curve and more anterior pelvic inclination when maximal trunk flexion is performed.

  11. Progressive multiple sequence alignments from triplets

    Directory of Open Access Journals (Sweden)

    Stadler Peter F

    2007-07-01

    Full Text Available Abstract Background The quality of progressive sequence alignments strongly depends on the accuracy of the individual pairwise alignment steps since gaps that are introduced at one step cannot be removed at later aggregation steps. Adjacent insertions and deletions necessarily appear in arbitrary order in pairwise alignments and hence form an unavoidable source of errors. Research Here we present a modified variant of progressive sequence alignments that addresses both issues. Instead of pairwise alignments we use exact dynamic programming to align sequence or profile triples. This avoids a large fractions of the ambiguities arising in pairwise alignments. In the subsequent aggregation steps we follow the logic of the Neighbor-Net algorithm, which constructs a phylogenetic network by step-wisely replacing triples by pairs instead of combining pairs to singletons. To this end the three-way alignments are subdivided into two partial alignments, at which stage all-gap columns are naturally removed. This alleviates the "once a gap, always a gap" problem of progressive alignment procedures. Conclusion The three-way Neighbor-Net based alignment program aln3nn is shown to compare favorably on both protein sequences and nucleic acids sequences to other progressive alignment tools. In the latter case one easily can include scoring terms that consider secondary structure features. Overall, the quality of resulting alignments in general exceeds that of clustalw or other multiple alignments tools even though our software does not included heuristics for context dependent (mismatch scores.

  12. Spring-Mediated Cranioplasty in Sagittal Synostosis: Does Age at Placement Affect Expansion?

    Science.gov (United States)

    Sun, James; Ter Maaten, Netanja S; Mazzaferro, Daniel M; Wes, Ari M; Naran, Sanjay; Bartlett, Scott P; Taylor, Jesse A

    2018-01-19

    The aim of this study is to evaluate the effect of timing of surgery and spring characteristics on correction of scaphocephalic deformity in patients undergoing spring-mediated cranioplasty (SMC) for sagittal craniosynostosis. The authors conducted a review of patients with sagittal craniosynostosis who underwent SMC at a tertiary referral center between July 2011 and March 2017, with a primary outcome measure of head shape, both preoperatively and postoperatively, determined by cephalic index (CI). Patient demographics and operative details including timing of surgery and spring characteristics were collected. Differences in CI preoperation and postoperation were compared using Wilcoxon signed-rank test. Ordinary least-squares linear regression was used to assess the impact of timing, number of springs, maximum single spring force, and total spring force on postoperative change in CI. Thirty-six subjects (12 males and 24 females) were included in the study. Mean age at spring placement was 3.9 months (range: 1.9-9.2) with a mean follow-up of 1.4 years (range: 0.3-5.2). The mean number of springs used was 3 (range: 2-4). The mean maximum single spring force was 9.9 Newtons (N) (range: 6.9-13.0) and the mean total spring force was 24.6 N (range: 12.7-37.0). Mean CI increased from 70 ± 0.9 preoperatively to 77 ± 1.0 postoperatively (P spring placement was significantly associated with change in CI: for every month increase in age, the change in CI decreased by 1.3 (P = 0.03). The number of springs used, greatest single spring force, and total spring force did not correlate with changes in CI (P = 0.85, P = 0.42, and P = 0.84, respectively). In SMC, earlier age at time of surgery appears to correlate with greater improvement in CI, at least in the short-term. While spring characteristics did not appear to affect head shape, it is possible that the authors were underpowered to detect a difference, and spring-related variables likely

  13. Contact pressure in the facet joint during sagittal bending of the cadaveric cervical spine.

    Science.gov (United States)

    Jaumard, Nicolas V; Bauman, Joel A; Weisshaar, Christine L; Guarino, Benjamin B; Welch, William C; Winkelstein, Beth A

    2011-07-01

    The facet joint contributes to the normal biomechanical function of the spine by transmitting loads and limiting motions via articular contact. However, little is known about the contact pressure response for this joint. Such information can provide a quantitative measure of the facet joint's local environment. The objective of this study was to measure facet pressure during physiologic bending in the cervical spine, using a joint capsule-sparing technique. Flexion and extension bending moments were applied to six human cadaveric cervical spines. Global motions (C2-T1) were defined using infra-red cameras to track markers on each vertebra. Contact pressure in the C5-C6 facet was also measured using a tip-mounted pressure transducer inserted into the joint space through a hole in the postero-inferior region of the C5 lateral mass. Facet contact pressure increased by 67.6 ± 26.9 kPa under a 2.4 Nm extension moment and decreased by 10.3 ± 9.7 kPa under a 2.7 Nm flexion moment. The mean rotation of the overall cervical specimen motion segments was 9.6 ± 0.8° and was 1.6 ± 0.7° for the C5-C6 joint, respectively, for extension. The change in pressure during extension was linearly related to both the change in moment (51.4 ± 42.6 kPa/Nm) and the change in C5-C6 angle (18.0 ± 108.9 kPa/deg). Contact pressure in the inferior region of the cervical facet joint increases during extension as the articular surfaces come in contact, and decreases in flexion as the joint opens, similar to reports in the lumbar spine despite the difference in facet orientation in those spinal regions. Joint contact pressure is linearly related to both sagittal moment and spinal rotation. Cartilage degeneration and the presence of meniscoids may account for the variation in the pressure profiles measured during physiologic sagittal bending. This study shows that cervical facet contact pressure can be directly measured with minimal disruption to the joint and is the first to provide local

  14. Aligning Assessments for COSMA Accreditation

    Science.gov (United States)

    Laird, Curt; Johnson, Dennis A.; Alderman, Heather

    2015-01-01

    Many higher education sport management programs are currently in the process of seeking accreditation from the Commission on Sport Management Accreditation (COSMA). This article provides a best-practice method for aligning student learning outcomes with a sport management program's mission and goals. Formative and summative assessment procedures…

  15. Global alignment algorithms implementations | Fatumo ...

    African Journals Online (AJOL)

    In this paper, we implemented the two routes for sequence comparison, that is; the dotplot and Needleman-wunsch algorithm for global sequence alignment. Our algorithms were implemented in python programming language and were tested on Linux platform 1.60GHz, 512 MB of RAM SUSE 9.2 and 10.1 versions.

  16. Aligning seminars with Bologna requirements

    DEFF Research Database (Denmark)

    Lueg, Rainer; Lueg, Klarissa; Lauridsen, Ole

    2016-01-01

    learning results, the authors suggest reciprocal peer tutoring (RPT); as a conceptual framework the authors suggest the SOLO (Structure of Observed Learning Outcomes) taxonomy and constructive alignment as suggested by Biggs and Tang. Our study presents results from the introduction of RPT in a large...

  17. Optimization of hindfoot alignment radiography.

    Science.gov (United States)

    Yang, Chonglin; Xu, Xiangyang; Hu, Mu; Wang, Bibo; Zhu, Yuan; Liu, Jinhao

    2017-06-01

    Background Cobey and Buck described methods to evaluate hindfoot alignment, but it is still unclear which method is better and easier to perform in clinical practice. Purpose To evaluate the optimal method for radiography of hindfoot alignment. Material and Methods We randomly selected 50 patients visiting the foot and ankle surgery outpatient department who underwent hindfoot alignment radiography between 1 July and 31 August 2015. Radiographs were taken using both Cobey's and Buck's methods. The patients were divided into three groups by calcaneal inclination angle. We assessed the calcaneotibial angle, calcaneovertical angle, and the distance from the bottom of the calcaneus to the mid-tibial axis. A comparative analysis was performed separately using the t-test. Results One hundred pairs of data for Cobey's and Buck's methods were obtained. The angles were analyzed separately in valgus, normal, and varus situations. The results showed no significant difference between Cobey's method and Buck's method regardless of any situation ( P > 0.05). Regarding the distance between the bottom of the calcaneus and the mid-tibial axis, the average result of Buck's method was about 1 mm larger than that of Cobey's method in the valgus and normal cases ( P  0.05). Conclusion Cobey's and Buck's techniques are the classic and popular hindfoot alignment assessment methods. The use of Buck's technique resulted in a better image with a less technical procedure and less time requirement. It is worthy of being popularized and used routinely for hindfoot radiography.

  18. Multimodal alignment during collaborative remembering

    NARCIS (Netherlands)

    Cienki, A.J.; Bietti, L.M.; Kok, K.I.

    2014-01-01

    This article investigates the roles that interactive alignment of manual gesture, postural sway, and eye-gaze play in small groups engaged in collaborative remembering. Qualitative analyses of a video corpus demonstrate that the coordination of these behaviors may contribute to joint remembering in

  19. Radiographic Analysis of Cervical and Spinal Alignment in Multilevel ACDF with Lordotic Interbody Device.

    Science.gov (United States)

    Katsuura, Yoshihiro; Lemons, Alex; Lorenz, Eileen; Swafford, Rachel; Osborn, James; Cason, Garrick

    2017-01-01

    Restoration and maintenance of cervical lordosis is an important clinical parameter in spine surgery. The purpose of this study was to determine the extent to which a multilevel anterior cervical discectomy and fusion (ACDF: greater than 3 levels) procedure restores cervical lordosis and the affect of increasing lordosis on sagittal vertical axis. We performed a retrospective radiographic analysis of 69 patients who underwent multilevel ACDF by 2 surgeons between 2013 and 2014. We measured the global and segmental sagittal alignment of the cervical spine using the cobb method at 4 time intervals (preop, post op 4wks, 10wks and 6 months) as well as the sagittal vertical axis (SVA) using both a C1-S1 and C7-S1 plumb line methods at 2 time intervals (preop and post op 4wks). Radiographs were measured by three reviewers. Interrater reliability was good to excellent for all measurements. Cervical lordosis significantly increased from preop 10.26° to 4 weeks postop 19.44° and was maintained up to 6 months 19.34 (p<0.0005). Segmental cervical lordosis was also significantly increased from preop 8.22° to post op at 4 weeks (20.26°) and was maintained at post op 10weeks 20.30° and post op 6 months 19.56° (p<0.0005). C7-S1 SVA and C1-S1 SVA also significantly increased from 12.04mm preop to 27.49mm post op 4 wks (p<0.0005) and -1.93mm preop to 8.67mm post op (p<0.0005) respectively. A change in C2-C7 lordosis positively correlated with a change in C7-SVA and C1-SVA (r=0.37, P<0.005, and r=0.312, p<0.05 respectively). Multilevel ACDF significantly increases and maintains both segmental and global cervical lordosis up to 6 months after surgery. Increasing C2-C7 global lordosis is correlated with increasing positive sagittal vertical axis. Level of evidence: IV.

  20. Sagittal and Vertical Craniofacial Growth Pattern and Timing of Circumpubertal Skeletal Maturation: A Multiple Regression Study

    Science.gov (United States)

    Rosso, Luigi; Riatti, Riccardo

    2016-01-01

    The knowledge of the associations between the timing of skeletal maturation and craniofacial growth is of primary importance when planning a functional treatment for most of the skeletal malocclusions. This cross-sectional study was thus aimed at evaluating whether sagittal and vertical craniofacial growth has an association with the timing of circumpubertal skeletal maturation. A total of 320 subjects (160 females and 160 males) were included in the study (mean age, 12.3 ± 1.7 years; range, 7.6–16.7 years). These subjects were equally distributed in the circumpubertal cervical vertebral maturation (CVM) stages 2 to 5. Each CVM stage group also had equal number of females and males. Multiple regression models were run for each CVM stage group to assess the significance of the association of cephalometric parameters (ANB, SN/MP, and NSBa angles) with age of attainment of the corresponding CVM stage (in months). Significant associations were seen only for stage 3, where the SN/MP angle was negatively associated with age (β coefficient, −0.7). These results show that hyperdivergent and hypodivergent subjects may have an anticipated and delayed attainment of the pubertal CVM stage 3, respectively. However, such association remains of little entity and it would become clinically relevant only in extreme cases. PMID:27995136

  1. Sagittal and Vertical Craniofacial Growth Pattern and Timing of Circumpubertal Skeletal Maturation: A Multiple Regression Study

    Directory of Open Access Journals (Sweden)

    Giuseppe Perinetti

    2016-01-01

    Full Text Available The knowledge of the associations between the timing of skeletal maturation and craniofacial growth is of primary importance when planning a functional treatment for most of the skeletal malocclusions. This cross-sectional study was thus aimed at evaluating whether sagittal and vertical craniofacial growth has an association with the timing of circumpubertal skeletal maturation. A total of 320 subjects (160 females and 160 males were included in the study (mean age, 12.3±1.7 years; range, 7.6–16.7 years. These subjects were equally distributed in the circumpubertal cervical vertebral maturation (CVM stages 2 to 5. Each CVM stage group also had equal number of females and males. Multiple regression models were run for each CVM stage group to assess the significance of the association of cephalometric parameters (ANB, SN/MP, and NSBa angles with age of attainment of the corresponding CVM stage (in months. Significant associations were seen only for stage 3, where the SN/MP angle was negatively associated with age (β coefficient, −0.7. These results show that hyperdivergent and hypodivergent subjects may have an anticipated and delayed attainment of the pubertal CVM stage 3, respectively. However, such association remains of little entity and it would become clinically relevant only in extreme cases.

  2. Conical geometry for sagittal focusing as applied to X rays from synchrotrons

    International Nuclear Information System (INIS)

    Ice, G.E.; Sparks, C.J.

    1993-06-01

    The authors describe a method for simultaneously focusing and monochromatization of X rays from a fan of radiation having up to 15 mrad divergence in one dimension. This geometry is well suited to synchrotron radiation sources at magnifications of one-fifth to two and is efficient for X-ray energies between 3 and 40 keV (0.48 and 6.4 fJ). The method uses crystals bent to part of a cone for sagittal focusing and allows for the collection of a larger divergence with less mixing of the horizontal into the vertical divergence than is possible with X-ray mirrors. They describe the geometry required to achieve the highest efficiency when a conical crystal follows a flat crystal in a nondispersive two-crystal monochromator. At a magnification of one-third, the geometry is identical to a cylindrical focusing design described previously. A simple theoretical calculation is shown to agree well with ray-tracing results. Minimum aberrations are observed at magnifications near one. Applications of the conical focusing geometry to existing and future synchrotron radiation facilities are discussed

  3. Influence of the design in sagittal split ramus osteotomy on the mechanical behavior.

    Science.gov (United States)

    Pozzer, Leandro; Olate, Sergio; Cavalieri-Pereira, Lucas; de Moraes, Márcio; Albergaría-Barbosa, José Ricardo

    2014-01-01

    The aim of this study was to determine the influence of the design of the sagittal split ramus osteotomy (SSRO) on the mechanical resistance to vertical forces. An in vitro study was designed for 30 test specimens. Two osteotomy models were made on two polyurethane hemimandibles, where group I presented a SSRO with an angle at vestibular level between both molars and group II presented a linear SSRO towards the basilar border. In both groups a standard osteosynthesis was performed with a 2.0 system plate and four monocortical screws, establishing sub-groups according to the degree of mandibular advancement: group A without advancement, group B with an advancement of 3 mm, and group C with advancement of 7 mm. Hemimandibles were subjected to a vertical load in the Instron machine until reaching peak load with failure, recording the value of the load and displacement. The data were analyzed with a t-test to establish statistical significance, considering pdesign influences mechanical resistance and that the linear SSRO offers the best mechanical resistance.

  4. Reliable sagittal plane kinematic gait assessments are feasible using low-cost webcam technology.

    Science.gov (United States)

    Saner, Robert J; Washabaugh, Edward P; Krishnan, Chandramouli

    2017-07-01

    Three-dimensional (3-D) motion capture systems are commonly used for gait analysis because they provide reliable and accurate measurements. However, the downside of this approach is that it is expensive and requires technical expertise; thus making it less feasible in the clinic. To address this limitation, we recently developed and validated (using a high-precision walking robot) a low-cost, two-dimensional (2-D) real-time motion tracking approach using a simple webcam and LabVIEW Vision Assistant. The purpose of this study was to establish the repeatability and minimal detectable change values of hip and knee sagittal plane gait kinematics recorded using this system. Twenty-one healthy subjects underwent two kinematic assessments while walking on a treadmill at a range of gait velocities. Intraclass correlation coefficients (ICC) and minimal detectable change (MDC) values were calculated for commonly used hip and knee kinematic parameters to demonstrate the reliability of the system. Additionally, Bland-Altman plots were generated to examine the agreement between the measurements recorded on two different days. The system demonstrated good to excellent reliability (ICC>0.75) for all the gait parameters tested on this study. The MDC values were typically low (gait assessments using webcam technology can be reliably used for clinical and research purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Assessing delay and lag in sagittal trunk control using a tracking task.

    Science.gov (United States)

    Reeves, N Peter; Luis, Abraham; Chan, Elizabeth C; Sal Y Rosas, Victor G; Tanaka, Martin L

    2018-03-17

    Slower trunk muscle responses are linked to back pain and injury. Unfortunately, clinical assessments of spine function do not objectively evaluate this important attribute, which reflects speed of trunk control. Speed of trunk control can be parsed into two components: (1) delay, the time it takes to initiate a movement, and (2) lag, the time it takes to execute a movement once initiated. The goal of this study is to demonstrate a new approach to assess delay and lag in trunk control using a simple tracking task. Ten healthy subjects performed four blocks of six trials of trunk tracking in the sagittal plane. Delay and lag were estimated by modeling trunk control for predictable and unpredictable (control mode) trunk movements in flexion and extension (control direction) at movement amplitudes of 2°, 4°, and 6° (control amplitude). The main effect of control mode, direction, and amplitude of movement were compared between trial blocks to assess secondary influencers (e.g., fatigue). Only control mode was consistent across trial blocks with predictable movements being faster than unpredictable for both delay and lag. Control direction and amplitude effects on delay and lag were consistent across the first two trial blocks and less consistent in later blocks. Given the heterogeneity in the presentation of back pain, clinical assessment of trunk control should include different control modes, directions, and amplitudes. To reduce testing time and the influence of fatigue, we recommend six trials to assess trunk control. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Frank-ter Haar syndrome associated with sagittal craniosynostosis and raised intracranial pressure.

    Science.gov (United States)

    Bendon, Charlotte L; Fenwick, Aimée L; Hurst, Jane A; Nürnberg, Gudrun; Nürnberg, Peter; Wall, Steven A; Wilkie, Andrew O M; Johnson, David

    2012-11-09

    Frank-ter Haar syndrome is a rare disorder associated with skeletal, cardiac, ocular and craniofacial features including hypertelorism and brachycephaly. The most common underlying genetic defect in Frank-ter Haar syndrome appears to be a mutation in the SH3PXD2B gene on chromosome 5q35.1. Craniosynostosis, or premature fusion of the calvarial sutures, has not previously been described in Frank-ter Haar syndrome. We present a family of three affected siblings born to consanguineous parents with clinical features in keeping with a diagnosis of Frank-ter Haar syndrome. All three siblings have a novel mutation caused by the deletion of exon 13 of the SH3PXD2B gene. Two of the three siblings also have non-scaphocephalic sagittal synostosis associated with raised intracranial pressure. The clinical features of craniosynostosis and raised intracranial pressure in this family with a confirmed diagnosis of Frank-ter Haar syndrome expand the clinical spectrum of the disease. The abnormal cranial proportions in a mouse model of the disease suggests that the association is not coincidental. The possibility of craniosynostosis should be considered in individuals with a suspected diagnosis of Frank-ter Haar syndrome.

  7. Frank-ter Haar syndrome associated with sagittal craniosynostosis and raised intracranial pressure

    Directory of Open Access Journals (Sweden)

    Bendon Charlotte L

    2012-11-01

    Full Text Available Abstract Background Frank-ter Haar syndrome is a rare disorder associated with skeletal, cardiac, ocular and craniofacial features including hypertelorism and brachycephaly. The most common underlying genetic defect in Frank-ter Haar syndrome appears to be a mutation in the SH3PXD2B gene on chromosome 5q35.1. Craniosynostosis, or premature fusion of the calvarial sutures, has not previously been described in Frank-ter Haar syndrome. Case presentation We present a family of three affected siblings born to consanguineous parents with clinical features in keeping with a diagnosis of Frank-ter Haar syndrome. All three siblings have a novel mutation caused by the deletion of exon 13 of the SH3PXD2B gene. Two of the three siblings also have non-scaphocephalic sagittal synostosis associated with raised intracranial pressure. Conclusion The clinical features of craniosynostosis and raised intracranial pressure in this family with a confirmed diagnosis of Frank-ter Haar syndrome expand the clinical spectrum of the disease. The abnormal cranial proportions in a mouse model of the disease suggests that the association is not coincidental. The possibility of craniosynostosis should be considered in individuals with a suspected diagnosis of Frank-ter Haar syndrome.

  8. Sagittal plane lumbar loading when navigating an obstacle and carrying a load.

    Science.gov (United States)

    Kiriella, Jeevaka B; Perry, Carolyn J; Hawkins, Kara M; Shanahan, Camille J; Gage, William H; Moore, Anne E

    2016-11-01

    The current study quantified lumbar loading while carrying an anterior load mass and navigating an obstacle. Eight healthy male participants walked down a walkway and crossed an obstacle under three randomised LOAD conditions; empty-box (2 KG), five kilogram (5 KG) and ten kilogram (10 KG). Each walk was assessed at two events: left foot mid-stance (LMS) and right toe-crossing (TC) to characterise any changes from approach to crossing. Measures of interest included: trunk pitch, L4/L5 joint moment, compression, joint anterior-posterior shear and erector spinae activation. Findings demonstrate that obstacle crossing extended posture by 50, 41, 44%, respectively for each carried load magnitude. Further, these results indicate that shear rather than compressive loading may be an important consideration during crossing due to increase by 8, 9, 22% from LMS to TC for each load magnitude tested. These results provide insight into sagittal lumbar loading when navigating an obstacle while carrying a load. Practitioner Summary: The risk of carrying while navigating obstacles on the lumbar spine is not completely understood. The forces at the lumbar spine while simultaneously carrying and obstacle crossing were analysed. Data indicate that carrying and obstacle crossing influence lumbar shear loads, thereby moderately increasing the relative risk at lumbar spine.

  9. Comparison of normal permanent and primary dentition sagittal tooth-crown inclinations of Japanese females.

    Science.gov (United States)

    Inada, Emi; Saitoh, Issei; Hayasaki, Haruaki; Iwase, Yoko; Kubota, Naoko; Takemoto, Yoshihiko; Yamasaki, Youichi

    2012-01-01

    The purpose of this study was to clarify the characteristics of permanent and primary tooth-crown inclinations. Landmark points from cephalograms and dental casts of two groups; 23 women (mean 20.3 +/- 3.3 years) and 11 girls (mean 5.2 +/- 0.1 years) were digitized, and the coordinates were integrated and transformed to a standardized plane. The 3-dimensional crown inclinations were projected on the sagittal plane, and the angles between the tooth vectors and the FH plane were calculated. An independent-group t-test was used to test for group differences of each tooth inclination, and correlation coefficients were generated for the inclination angles among the permanent and primary teeth. Most maxillary tooth-crown inclinations showed significant age-related differences, while only the second premolar and primary second molar differed significantly in the mandible. The maxillary molars were parallel to the corresponding mandibular molars and correlated with each other, but the primary molars were not. Significant correlations were found between inclinations of most permanent teeth, but not the primary teeth. Maxillary tooth-crown inclinations change during growth, but tooth-crown inclinations of the mandibular teeth do not.

  10. SVR versus neural-fuzzy network controllers for the sagittal balance of a biped robot.

    Science.gov (United States)

    Ferreira, João P; Crisóstomo, Manuel M; Coimbra, A Paulo

    2009-12-01

    The real-time balance control of an eight-link biped robot using a zero moment point (ZMP) dynamic model is difficult due to the processing time of the corresponding equations. To overcome this limitation, two alternative intelligent computing control techniques were compared: one based on support vector regression (SVR) and another based on a first-order Takagi-Sugeno-Kang (TSK)-type neural-fuzzy (NF) network. Both methods use the ZMP error and its variation as inputs and the output is the correction of the robot's torso necessary for its sagittal balance. The SVR and the NF were trained based on simulation data and their performance was verified with a real biped robot. Two performance indexes are proposed to evaluate and compare the online performance of the two control methods. The ZMP is calculated by reading four force sensors placed under each robot's foot. The gait implemented in this biped is similar to a human gait that was acquired and adapted to the robot's size. Some experiments are presented and the results show that the implemented gait combined either with the SVR controller or with the TSK NF network controller can be used to control this biped robot. The SVR and the NF controllers exhibit similar stability, but the SVR controller runs about 50 times faster.

  11. Ancestral sequence alignment under optimal conditions

    Directory of Open Access Journals (Sweden)

    Brown Daniel G

    2005-11-01

    Full Text Available Abstract Background Multiple genome alignment is an important problem in bioinformatics. An important subproblem used by many multiple alignment approaches is that of aligning two multiple alignments. Many popular alignment algorithms for DNA use the sum-of-pairs heuristic, where the score of a multiple alignment is the sum of its induced pairwise alignment scores. However, the biological meaning of the sum-of-pairs of pairs heuristic is not obvious. Additionally, many algorithms based on the sum-of-pairs heuristic are complicated and slow, compared to pairwise alignment algorithms. An alternative approach to aligning alignments is to first infer ancestral sequences for each alignment, and then align the two ancestral sequences. In addition to being fast, this method has a clear biological basis that takes into account the evolution implied by an underlying phylogenetic tree. In this study we explore the accuracy of aligning alignments by ancestral sequence alignment. We examine the use of both maximum likelihood and parsimony to infer ancestral sequences. Additionally, we investigate the effect on accuracy of allowing ambiguity in our ancestral sequences. Results We use synthetic sequence data that we generate by simulating evolution on a phylogenetic tree. We use two different types of phylogenetic trees: trees with a period of rapid growth followed by a period of slow growth, and trees with a period of slow growth followed by a period of rapid growth. We examine the alignment accuracy of four ancestral sequence reconstruction and alignment methods: parsimony, maximum likelihood, ambiguous parsimony, and ambiguous maximum likelihood. Additionally, we compare against the alignment accuracy of two sum-of-pairs algorithms: ClustalW and the heuristic of Ma, Zhang, and Wang. Conclusion We find that allowing ambiguity in ancestral sequences does not lead to better multiple alignments. Regardless of whether we use parsimony or maximum likelihood, the

  12. GraphAlignment: Bayesian pairwise alignment of biological networks

    Czech Academy of Sciences Publication Activity Database

    Kolář, Michal; Meier, J.; Mustonen, V.; Lässig, M.; Berg, J.

    2012-01-01

    Roč. 6, November 21 (2012) ISSN 1752-0509 Grant - others:Deutsche Forschungsgemeinschaft(DE) SFB 680; Deutsche Forschungsgemeinschaft(DE) SFB-TR12; Deutsche Forschungsgemeinschaft(DE) BE 2478/2-1 Institutional research plan: CEZ:AV0Z50520514 Keywords : Graph alignment * Biological networks * Parameter estimation * Bioconductor Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.982, year: 2012

  13. Jig Aligns Shadow Mask On CCD

    Science.gov (United States)

    Matus, Carlos V.

    1989-01-01

    Alignment viewed through microscope. Alignment jig positions shadow mask on charge-coupled device (CCD) so metal film deposited on it precisely. Allows CCD package to be inserted and removed without disturbing alignment of mask. Holds CCD packages securely and isolates it electrostatically while providing electrical contact to each of its pins. When alignment jig assembled with CCD, used to move mask under micrometer control.

  14. Clinical Follow-up on Sagittal Fracture at the Temporal Root of the Zygomatic Arch: Does It Need Open Reduction?

    Directory of Open Access Journals (Sweden)

    Ji Seon Cheon

    2013-09-01

    Full Text Available BackgroundThe zygoma is a major portion of the midfacial contour. When deformity occurs in this area, a reduction should be conducted to correct it. If a sagittal fracture at the temporal root of the zygomatic arch occurs, this also requires reduction, but it is difficult to approach due to its anatomical location, and the possibility of fixation is also limited. Thus, the authors attempted the reduction of sagittal fracture by two- or three-point fixation and the Gillies approach without direct manipulation. The preoperative and postoperative results of the patients were evaluated. Follow-up was performed to establish a treatment guideline.MethodsA retrospective study was done with 40 patients who had sagittal fractures at the temporal root of the zygomatic arch from March 2009 to June 2012. Only two- or three-point fixation was performed for the accompanying zygomatic-orbital-maxillary fracture. The Gillies approach was used for complex fractures of the zygomatic arch, while the temporal root of the zygomatic arch was only observed without reduction. Preoperative and postoperative computed tomography and X-ray scans were performed to examine the results.ResultsThe result of the paired t-test on preoperative and postoperative bone gap differences, the depression level, and the degree of temporal protrusion showed a marked decrease in the mean difference at a 95% confidence interval. The results were acceptable.ConclusionsIn the treatment of sagittal fractures at the temporal root of the zygomatic arch, it is acceptable to use indirect reduction and non-fixation methods. This leads to a satisfactory aesthetic and functional outcome.

  15. Clinical Follow-up on Sagittal Fracture at the Temporal Root of the Zygomatic Arch: Does It Need Open Reduction?

    Directory of Open Access Journals (Sweden)

    Ji Seon Cheon

    2013-09-01

    Full Text Available Background The zygoma is a major portion of the midfacial contour. When deformity occursin this area, a reduction should be conducted to correct it. If a sagittal fracture at the temporalroot of the zygomatic arch occurs, this also requires reduction, but it is difficult to approachdue to its anatomical location, and the possibility of fixation is also limited. Thus, the authorsattempted the reduction of sagittal fracture by two- or three-point fixation and the Gilliesapproach without direct manipulation. The preoperative and postoperative results of thepatients were evaluated. Follow-up was performed to establish a treatment guideline.Methods A retrospective study was done with 40 patients who had sagittal fractures at thetemporal root of the zygomatic arch from March 2009 to June 2012. Only two- or three-pointfixation was performed for the accompanying zygomatic-orbital-maxillary fracture. The Gilliesapproach was used for complex fractures of the zygomatic arch, while the temporal root ofthe zygomatic arch was only observed without reduction. Preoperative and postoperativecomputed tomography and X-ray scans were performed to examine the results.Results The result of the paired t-test on preoperative and postoperative bone gap differences,the depression level, and the degree of temporal protrusion showed a marked decrease in themean difference at a 95% confidence interval. The results were acceptable.Conclusions In the treatment of sagittal fractures at the temporal root of the zygomatic arch,it is acceptable to use indirect reduction and non-fixation methods. This leads to a satisfactoryaesthetic and functional outcome.

  16. Sagittal Abdominal Diameter as a Surrogate Marker of Insulin Resistance in an Admixtured Population?Brazilian Metabolic Syndrome Study (BRAMS)

    OpenAIRE

    Vasques, Ana Carolina J.; Cassani, Roberta S. L.; Forti, Adriana C. e; Vilela, Brunna S.; Pareja, Jos? Carlos; Tambascia, Marcos Antonio; Geloneze, Bruno

    2015-01-01

    Background Sagittal abdominal diameter (SAD) has been proposed as a surrogate marker of insulin resistance (IR). However, the utilization of SAD requires specific validation for each ethnicity. We aimed to investigate the potential use of SAD, compared with classical anthropometrical parameters, as a surrogate marker of IR and to establish the cutoff values of SAD for screening for IR. Methods A multicenter population survey on metabolic disorders was conducted. A race-admixtured sample of 82...

  17. Sagittal Plane Knee Biomechanics and Vertical Ground Reaction Forces Are Modified Following ACL Injury Prevention Programs: A Systematic Review.

    Science.gov (United States)

    Padua, Darin A; Distefano, Lindsay J

    2009-03-01

    Injuries to the anterior cruciate ligament (ACL) occur because of excessive loading on the knee. ACL injury prevention programs can influence sagittal plane ACL loading factors and vertical ground reaction force (VGRF). To determine the influence of ACL injury prevention programs on sagittal plane knee biomechanics (anterior tibial shear force, knee flexion angle/moments) and VGRF. The PubMed database was searched for studies published between January 1988 and June 2008. Reference lists of selected articles were also reviewed. Studies were included that evaluated healthy participants for knee flexion angle, sagittal plane knee kinetics, or VGRF after performing a multisession training program. Two individuals reviewed all articles and determined which articles met the selection criteria. Approximately 4% of the articles fulfilled the selection criteria. Data were extracted regarding each program's duration, frequency, exercise type, population, supervision, and testing procedures. Means and variability measures were recorded to calculate effect sizes. One reviewer extracted all data and assessed study quality using PEDro (Physiotherapy Evidence Database). A second reviewer (blinded) verified all information. There is moderate evidence to indicate that knee flexion angle, external knee flexion moment, and VGRF can be successfully modified by an ACL injury prevention program. Programs utilizing multiple exercises (ie, integrated training) appear to produce the most improvement, in comparison to that of single-exercise programs. Knee flexion angle was improved following integrated training (combined balance and strength exercises or combined plyometric and strength exercises). Similarly, external knee flexion moment was improved following integrated training consisting of balance, plyometric, and strength exercises. VGRF was improved when incorporating supervision with instruction and feedback on proper technique. ACL injury prevention programs that are aimed at

  18. BMD measurements of the spine derived from sagittal reformations of contrast-enhanced MDCT without dedicated software

    Energy Technology Data Exchange (ETDEWEB)

    Baum, Thomas, E-mail: thbaum@gmx.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Mueller, Dirk, E-mail: dirk.mueller@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Dobritz, Martin, E-mail: dobritz@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Rummeny, Ernst J., E-mail: institut@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Link, Thomas M., E-mail: thomas.link@radiology.ucsf.edu [Musculoskeletal and Quantitative Imaging Research, Department of Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry Street, Suite 350, San Francisco, CA 94107 (United States); Bauer, Jan S., E-mail: jsb@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany)

    2011-11-15

    Purpose: To assess QCT equivalent BMD of the lumbar spine in sagittal reformations of routine abdominal contrast-enhanced MDCT with simple PACS measurement tools and to apply this method to MDCT datasets for differentiating patients with and without osteoporotic vertebral fractures. Materials and methods: Eight postmenopausal women (65 {+-} 5years) underwent standard QCT to assess BMD of L1-L3. Afterwards routine abdominal contrast-enhanced MDCT images of these women were obtained and apparent BMD of L1-L3 was measured using the sagittal reformations. The MDCT-to-QCT conversion equation for BMD was calculated with linear regression analysis. The conversion equation was applied to vertebral BMD datasets (L1-L3) of 75 postmenopausal women (66 {+-} 4years). Seventeen of the 75 patients had osteoporotic vertebral fractures. Results: BMD values of contrast-enhanced MDCT were on average 56 mg/ml higher than those of standard QCT. A correlation coefficient of r = 0.94 (p < 0.05) was calculated for the BMD values of MDCT and standard QCT with the conversion equation BMD{sub QCT} = 0.69 x BMD{sub MDCT} - 11 mg/ml. Accordingly converted BMD values of patients with vertebral fractures were significantly lower than those of patients without vertebral fractures (69 mg/ml vs. 85 mg/ml; p < 0.05). Using ROC analysis to differentiate patients with and without vertebral fractures, AUC = 0.72 was obtained for converted BMD values (p < 0.05). Short- and long-term reproducibility errors for BMD measurements in the sagittal reformations amounted 2.09% and 7.70%, respectively. Conclusion: BMD measurements of the spine could be computed in sagittal reformations of routine abdominal contrast-enhanced MDCT with minimal technical and time effort. Using the conversion equation, the acquired BMD data could differentiate patients with and without osteoporotic vertebral fractures.

  19. The Comparison of Sagittal Spinopelvic Parameters between Young Adult Patients with L5 Spondylolysis and Age-Matched Control Group

    OpenAIRE

    Oh, Young Min; Choi, Ha Young; Eun, Jong Pil

    2013-01-01

    Objective To compare spinopelvic parameters in young adult patients with spondylolysis to those in age-matched patients without spondylolysis and investigate the clinical impact of sagittal spinopelvic parameters in patients with L5 spondylolysis. Methods From 2009 to 2012, a total of 198 young adult male patients with spondylolysis were identified. Eighty age-matched patients without spondylolysis were also selected. Standing lateral films that included both hip joints were obtained for each...

  20. Alignment of the VISA Undulator

    International Nuclear Information System (INIS)

    Ruland, Robert E.

    2000-01-01

    As part of the R and D program towards a fourth generation light source, a Self-Amplified Spontaneous Emission (SASE) demonstration is being prepared. The Visible-Infrared SASE Amplifier (VISA) undulator is being installed at Brookhaven National Laboratory. The VISA undulator is an in-vacuum, 4-meter long, 1.8 cm period, pure-permanent magnet device, with a novel, strong focusing, permanent magnet FODO array included within the fixed, 6 mm undulator gap. The undulator is constructed of 99 cm long segments. To attain maximum SASE gain requires establishing overlap of electron and photon beams to within 50 pm rms. This imposes challenging tolerances on mechanical fabrication and magnetic field quality, and necessitates use of laser straightness interferometry for calibration and alignment of the magnetic axes of the undulator segments. This paper describes the magnetic centerline determination, and the fiducialization and alignment processes, which were performed to meet the tolerance goal

  1. Shuttle onboard IMU alignment methods

    Science.gov (United States)

    Henderson, D. M.

    1976-01-01

    The current approach to the shuttle IMU alignment is based solely on the Apollo Deterministic Method. This method is simple, fast, reliable and provides an accurate estimate for the present cluster to mean of 1,950 transformation matrix. If four or more star sightings are available, the application of least squares analysis can be utilized. The least squares method offers the next level of sophistication to the IMU alignment solution. The least squares method studied shows that a more accurate estimate for the misalignment angles is computed, and the IMU drift rates are a free by-product of the analysis. Core storage requirements are considerably more; estimated 20 to 30 times the core required for the Apollo Deterministic Method. The least squares method offers an intermediate solution utilizing as much data that is available without a complete statistical analysis as in Kalman filtering.

  2. Biomechanical Loading Evaluation of Unsintered Hydroxyapatite/poly-l-lactide Plate System in Bilateral Sagittal Split Ramus Osteotomy

    Directory of Open Access Journals (Sweden)

    Shintaro Sukegawa

    2017-07-01

    Full Text Available OSTEOTRANS MX® (Takiron Co., Ltd., Osaka, Japan is a bioactive resorbable maxillofacial osteosynthetic material composed of an unsintered hydroxyapatite/poly-l-lactide composite, and its effective osteoconductive capacity has been previously documented. However, the mechanical strength of this plate system is unclear. Thus, the aim of this in vitro study was to assess its tensile and shear strength and evaluate the biomechanical intensity of different osteosynthesis plate designs after sagittal split ramus osteotomy by simulating masticatory forces in a clinical setting. For tensile and shear strength analyses, three mechanical strength measurement samples were prepared by fixing unsintered hydroxyapatite/poly-l-lactide composed plates to polycarbonate skeletal models. Regarding biomechanical loading evaluation, 12 mandibular replicas were used and divided into four groups for sagittal split ramus osteotomy fixation. Each sample was secured in a jig and subjected to vertical load on the first molar teeth. Regarding shear strength, the novel-shaped unsintered hydroxyapatite/poly-l-lactide plate had significantly high intensity. Upon biomechanical loading evaluation, this plate system also displayed significantly high stability in addition to bioactivity, with no observed plate fracture. Thus, we have clearly demonstrated the efficacy of this plate system using an in vitro model of bilateral sagittal split ramus osteotomy of the mandible.

  3. Normal values of the sagittal diameter of the lumbar spine (vertebral body and dural sac) in children measured by MRI

    International Nuclear Information System (INIS)

    Knirsch, Walter; Kurtz, Claudia; Langer, Mathias; Haeffner, Nicole; Kececioglu, Deniz

    2005-01-01

    The definition of normal values is a prerequisite for the reliable evaluation of abnormality in the lumbar spine, such as spinal canal stenosis or dural ectasia in patients with Marfan syndrome. Values for vertebral body diameter (VBD) and dural sac diameter (DSD) for the lumbar spine have been published in adults. In children, normal values have been established using conventional radiography or myelography, but not by MRI. To define normal values for the sagittal diameter of the vertebral body and dural sac, and to calculate a dural sac ratio (DSR) in the lumbosacral spine (L1-S1) in healthy children using MRI. A total of 75 healthy children between 6 years and 17 years of age were examined using a sagittal T2-weighted sequence. Sagittal VBD and DSD were measured and a DSR was calculated. This was a retrospective and cross-sectional study. With increasing age there is a significant increase of VBD, a slight increase of DSD, and a slight decrease of DSR. There is no significant sex difference. DSR in healthy children is higher than in healthy adults. MRI is a reliable method demonstrating the natural shape of the lumbosacral spine and its absolute values. These normal values compare well with those established by conventional radiological techniques. Our data may serve as a reference for defining dural ectasia in children with Marfan syndrome. (orig.)

  4. Normal values of the sagittal diameter of the lumbar spine (vertebral body and dural sac) in children measured by MRI

    Energy Technology Data Exchange (ETDEWEB)

    Knirsch, Walter [University Children' s Hospital Freiburg, Department of Pediatric Cardiology, Freiburg (Germany); University Children' s Hospital Zurich, Division of Paediatric Cardiology, Zurich (Switzerland); Kurtz, Claudia; Langer, Mathias [University Hospital Freiburg, Department of Radiology, Freiburg (Germany); Haeffner, Nicole; Kececioglu, Deniz [University Children' s Hospital Freiburg, Department of Pediatric Cardiology, Freiburg (Germany)

    2005-04-01

    The definition of normal values is a prerequisite for the reliable evaluation of abnormality in the lumbar spine, such as spinal canal stenosis or dural ectasia in patients with Marfan syndrome. Values for vertebral body diameter (VBD) and dural sac diameter (DSD) for the lumbar spine have been published in adults. In children, normal values have been established using conventional radiography or myelography, but not by MRI. To define normal values for the sagittal diameter of the vertebral body and dural sac, and to calculate a dural sac ratio (DSR) in the lumbosacral spine (L1-S1) in healthy children using MRI. A total of 75 healthy children between 6 years and 17 years of age were examined using a sagittal T2-weighted sequence. Sagittal VBD and DSD were measured and a DSR was calculated. This was a retrospective and cross-sectional study. With increasing age there is a significant increase of VBD, a slight increase of DSD, and a slight decrease of DSR. There is no significant sex difference. DSR in healthy children is higher than in healthy adults. MRI is a reliable method demonstrating the natural shape of the lumbosacral spine and its absolute values. These normal values compare well with those established by conventional radiological techniques. Our data may serve as a reference for defining dural ectasia in children with Marfan syndrome. (orig.)

  5. Cephalometric Investigation of First Cervical Vertebrae Morphology and Hyoid Position in Young Adults with Different Sagittal Skeletal Patterns

    Science.gov (United States)

    Gündüz Arslan, Seher; Dildeş, Neval; Devecioglu Kama, Jalen

    2014-01-01

    The aim of this retrospective study was to examine hyoid bone position and C1 (atlas) morphology in males and females and analyze these parameters with respect to different sagittal skeletal patterns via cephalometry, with the goal of identifying cephalometric norms. Lateral cephalometric radiographs from 120 individuals (average age: 21.1 ± 2.9 years) were classified according to their ANB angle (Class I, II, or III) and used to assess 14 parameters. Class I and II patients showed significant differences in Hy-NSL, Hy-PD, Hy-CVT, Lum, and a-p measurements. These parameters were consistently larger in males than in females. Intergroup comparisons among males showed significant differences in the SNA, ANB, Hy-CVT, X, and Z measurements. The hyoid was positioned more inferiorly and anteriorly and was more prominent in males than in females in all groups. Among participants exhibiting a Class I skeletal pattern, C1 was also larger in the anterior-posterior direction in males than in females. In the sagittal plane, the hyoid was positioned similarly in males with either Class I or III skeletal patterns but was positioned posteriorly in males with a Class II skeletal pattern. In addition, the vertical position of C1 varied with sagittal skeletal pattern in males. PMID:25152900

  6. Assessing strategic alignment to improve IT effectiveness

    NARCIS (Netherlands)

    Smits, M.T.; Fairchild, A.M.; Ribbers, P.M.A.; Milis, K.; van Geel, E.; Markus, M.L.; Hampe, J.F.; Gricar, J.; Pucihar, A.; Lenart, G.

    2009-01-01

    A long running challenge in both large and small organizations has been aligning information systems services with business needs. Good alignment is assumed to lead to good business results, but there is a need for good instruments to assess strategic alignment and business success in practice.

  7. Physician-Hospital Alignment in Orthopedic Surgery.

    Science.gov (United States)

    Bushnell, Brandon D

    2015-09-01

    The concept of "alignment" between physicians and hospitals is a popular buzzword in the age of health care reform. Despite their often tumultuous histories, physicians and hospitals find themselves under increasing pressures to work together toward common goals. However, effective alignment is more than just simple cooperation between parties. The process of achieving alignment does not have simple, universal steps. Alignment will differ based on individual situational factors and the type of specialty involved. Ultimately, however, there are principles that underlie the concept of alignment and should be a part of any physician-hospital alignment efforts. In orthopedic surgery, alignment involves the clinical, administrative, financial, and even personal aspects of a surgeon's practice. It must be based on the principles of financial interest, clinical authority, administrative participation, transparency, focus on the patient, and mutual necessity. Alignment can take on various forms as well, with popular models consisting of shared governance and comanagement, gainsharing, bundled payments, accountable care organizations, and other methods. As regulatory and financial pressures continue to motivate physicians and hospitals to develop alignment relationships, new and innovative methods of alignment will also appear. Existing models will mature and evolve, with individual variability based on local factors. However, certain trends seem to be appearing as time progresses and alignment relationships deepen, including regional and national collaboration, population management, and changes in the legal system. This article explores the history, principles, and specific methods of physician-hospital alignment and its critical importance for the future of health care delivery. Copyright 2015, SLACK Incorporated.

  8. MUSTANG: a multiple structural alignment algorithm.

    Science.gov (United States)

    Konagurthu, Arun S; Whisstock, James C; Stuckey, Peter J; Lesk, Arthur M

    2006-08-15

    Multiple structural alignment is a fundamental problem in structural genomics. In this article, we define a reliable and robust algorithm, MUSTANG (MUltiple STructural AligNment AlGorithm), for the alignment of multiple protein structures. Given a set of protein structures, the program constructs a multiple alignment using the spatial information of the C(alpha) atoms in the set. Broadly based on the progressive pairwise heuristic, this algorithm gains accuracy through novel and effective refinement phases. MUSTANG reports the multiple sequence alignment and the corresponding superposition of structures. Alignments generated by MUSTANG are compared with several handcurated alignments in the literature as well as with the benchmark alignments of 1033 alignment families from the HOMSTRAD database. The performance of MUSTANG was compared with DALI at a pairwise level, and with other multiple structural alignment tools such as POSA, CE-MC, MALECON, and MultiProt. MUSTANG performs comparably to popular pairwise and multiple structural alignment tools for closely related proteins, and performs more reliably than other multiple structural alignment methods on hard data sets containing distantly related proteins or proteins that show conformational changes.

  9. An analysis of sequence alignment: heuristic algorithms.

    Science.gov (United States)

    Bucak, I Ö; Uslan, V

    2010-01-01

    Sequence alignment becomes challenging with an increase in size and number of sequences. Finding optimal or near optimal solutions for sequence alignment is one of the most important operations in bioinformatics. This study aims to survey heuristics applied for the sequence alignment problem summarized in a time line.

  10. Semiautomated improvement of RNA alignments

    DEFF Research Database (Denmark)

    Andersen, Ebbe Sloth; Lind-Thomsen, Allan; Knudsen, Bjarne

    2007-01-01

    : the mir-399 RNA, vertebrate telomase RNA (vert-TR), bacterial transfer-messenger RNA (tmRNA), and the signal recognition particle (SRP) RNA. The general use of the method is illustrated by the ability to accommodate pseudoknots and handle even large and divergent RNA families. The open architecture...... of the SARSE editor makes it a flexible tool to improve all RNA alignments with relatively little human intervention. Online documentation and software are available at (http://sarse.ku.dk)....

  11. Alignment in double capture processes

    Energy Technology Data Exchange (ETDEWEB)

    Moretto-Capelle, P.; Benhenni, M.; Bordenave-Montesquieu, A.; Benoit-Cattin, P.; Gleizes, A. (IRSAMC, URA CNRS 770, Univ. Paul Sabatier, 118 rte de Narbonne, 31062 Toulouse Cedex (France))

    1993-06-05

    The electron spectra emitted when a double capture occurs in N[sup 7+]+He and Ne[sup 8+]+He systems at 10 qkeV collisional energy, allow us to determine the angular distributions of the 3[ell]3[ell] [prime] lines through a special spectra fitting procedure which includes interferences between neighbouring states. It is found that the doubly excited states populated in double capture processes are generally aligned.

  12. International Business And Aligning CSR

    Directory of Open Access Journals (Sweden)

    Daniel Miret

    2017-11-01

    Full Text Available The labor relationship between the employer and the workers is evaluated and directed by the labor rights which is a group of legal rights that are derived from human rights. Labor rights are more precisely relative to CSR as CSR are based on perspective and point of view of a given corporation. In this perspective implementing the workers and labor rights becomes more difficult compared to the implementation of the CSR. If an international corporation can be able to align CSR with the labor laws the friction between the employees and the corporation and the employee is likely to reduce. There is need to explore whether multinational corporations can be able to align CSR with the labor rights and employee initiatives global market. In this case the analysis focuses on China Brazil and India as the reference countries with cross-sectional secondary data obtained from a survey of the existing sources on the internet. The pertinent question is whether multinational corporations be successful while aligning CSR Corporate Social Responsibility with labor rights and employee initiatives in a competitive global market based on that cross-sectional data. The findings reveal that the uphold of labor rights largely determines morale of the employees and the will to participate in the growth and development of a given business both locally and international. Notably the continued change of CSR has resulted in the replacement of management and government dominated trade unions with more democratic unions of workers that pay attention to the initiatives of the workers. The combination of the internal code of conduct with the workers association labor associations and movements is one of the credible routes that show CSR can be aligned with labor rights.

  13. An SXF Extension for Alignment

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pilat, F. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    1998-11-13

    The accelerator description in the standard exchange format SXF is now used for RHIC and the LHC. Parsers exist to a growing number of simulation programs. SXF, however, is a fiat ordered list of elements and does not support the simultaneous misalignment of adjacent elements. The introduction of an element hierarchy is needed to align several elements by the same amount. This is of interest for two reasons: First, magnets are often modeled by more than one element and all these elements should be misaligned by the same amount. For example, a magnet model may consist of a body and two end kicks; and the body itself may be modeled by several kicks. Second, sometimes there are several magnets assembled in one cryostat. It is then desirable to misalign the whole cryostat while the individual magnets within are misaligned relative to the cryostat. The proper description of alignment errors is of great importance to the US-LHC col­laboration in which the US will deliver assembled cryostat-s of interaction region magnets to CERN. In the design phase an estimate of tolerable alignment errors is needed. Once magnets are assembled in a cryostat, the best position of the cryostat must be found in order to minimize the harmful effects of field errors. We developed a description that allows the simultaneous misalignment of adjacent magnets. The description is closely related to the SXF format. A filter program can be used to process and merge the misalignment information into a flat SXF file.

  14. Osseous healing after sagittal splitting ramus osteotomy in mandibular prognathism. Three-dimensional CT measurement

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Toshiyuki; Akizuki, Hiromichi; Michi, Ken-ichi [Showa Univ., Tokyo (Japan). School of Dentistry

    2001-07-01

    The purpose of the present study was to clarify the relationship between the cleavage and fixation of bone fragments and the osseous healing after sagittal splitting ramus osteotomy. Subjects consisted of 12 patients with mandibular prognathism, on which we performed sagittal splitting ramus osteotomy on both sides. Thus, we performed this osteotomy on 24 rami. These rami were studied immediately after, and 1 year after, surgery by Three-dimensional CT. With regard to the morphology of the anterior and posterior borders of the mandibular ramus, the majority (70.8%) showed the smooth type (smooth type: proximal and distal bone fragments are not discernible, and there is a smooth transition between them) in the lower plane. In the upper plane, the smooth type was less frequent (39.6%), and the stairway type (stairway type: either the proximal bone fragment or the distal bone fragment is protruded, thus showing a stairway form) was more frequent (43.8%). The concave type (concave type: there is a gap, i.e. an opened bone fragment, between two bone fragments, thus showing a concave form) was more frequently observed at the anterior border than at the posterior border, in both planes. With regard to the relationship between the morphology of the posterior border of the mandibular ramus and the cleavage of proximal and distal fragments, the stairway type was more frequent if both fragments were completely split through the posterior border, but the smooth type was more frequent if the cleavage spared the posterior border. With regard to the relationship between the morphology of the anterior and posterior borders of the mandibular ramus and the distance between proximal and distal bone fragments, the distance was greatest in the concave type, followed by the stairway type and the smooth type, in this order. The concave type was observed in cases in which the mean distance was more than 6.1 mm. As for the relationship between the posterior protrusion of the distal bone

  15. Spinal curves and health: a systematic critical review of the epidemiological literature dealing with associations between sagittal spinal curves and health

    DEFF Research Database (Denmark)

    Christensen, Sanne Toftgaard; Hartvigsen, Jan

    2008-01-01

    The purposes of this study were to (1) determine whether sagittal spinal curves are associated with health in epidemiological studies, (2) estimate the strength of such associations, and (3) consider whether these relations are likely to be causal....

  16. Use of the Visante™ OCT to measure the sagittal depth and scleral shape of keratoconus compared to normal corneae: Pilot study

    Directory of Open Access Journals (Sweden)

    Luigina Sorbara

    2013-07-01

    Conclusions: Measurement of the sagittal depth and the corneal-scleral junction angle in the steepest meridian at either the HVID or at 15 mm are two metrics that significantly differentiate normals from keratoconics.

  17. Mandibular Sagittal Split Osteotomy for Removal of Impacted Mandibular Teeth: Indications, Surgical Pitfalls, and Final Outcome.

    Science.gov (United States)

    Catherine, Zulma; Scolozzi, Paolo

    2017-05-01

    The purpose of this study was to determine the indications for mandibular sagittal split osteotomy (MSSO) for the removal of impacted mandibular teeth and to evaluate the surgical pitfalls and final outcomes. In this retrospective case-series study, radiologic and clinical data of all patients who underwent MSSO for the removal of impacted mandibular teeth between 2008 and 2015 at the University Hospitals of Geneva were reviewed. The primary outcome variables were 1) the indication for the removal of impacted mandibular teeth by MSSO, 2) complications, and 3) surgical pitfalls. Other variables included age, gender, teeth involved, indication for tooth removal, concomitant lesions such as cysts and/or tumors, and radiologic features. In 18 consecutive patients, 21 impacted mandibular teeth (18 third molars, 2 second molars, and 1 first molar) were extracted by MSSO. In all patients the indication for the MSSO approach included deeply impacted teeth associated with an intimate relationship between the inferior alveolar nerve and the dental roots as shown on computed tomography or cone-beam computed tomography scan images. A non-disabling hypoesthesia of the inferior alveolar nerve developed in 6 patients (33.3%). Major complications occurred in 3 patients (16.6%), including 2 cases of infection (11.1%) and 1 case of a "bad split" (5.5%). This study showed that the MSSO approach is a valuable method for removing deeply impacted teeth in proximity to the mandibular canal. Local factors, such as bone remodeling, concomitant large lesions (cysts and/or tumors), and the mandibular canal within the buccal cortex, represent pitfalls that might increase the risk of complications developing. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Neonatal posterior sagittal anorectoplasty for a subset of males with high anorectal malformations

    Directory of Open Access Journals (Sweden)

    Nilesh G Nagdeve

    2011-01-01

    Full Text Available Aim: To assess the results of primary posterior sagittal anorectoplasty (PSARP in male neonates with high anorectal malformations (ARM who on invertogram showed well descended rectum. Materials and Methods: Twelve full-term male neonates with high ARM over a period of one and half years were selected for primary PSARP based on the findings of invertogram. Primary PSARP was performed in all neonates with lower limit of rectal gas bubble at or below the ossified fifth sacral vertebra. The patients were followed-up for a period between three to four and half years. The clinical evaluation of fecal continence was performed using Pena′s criteria for assessment of continence. Results: All neonates underwent PSARP on second to fourth postnatal day. The fistula with urinary tract was found in 11 patients (seven had fistula to bulbar urethra and four to prostatic urethra. Rectal tapering was not required in any neonate. No patient had urinary problems after removal of catheter. Most of the neonates were discharged by ninth day. Postoperatively, two patients had superficial wound infection of anoplasty without any disruption or bowel retraction. Two patients had severe perianal excoriation. No patient had anorectal stenosis. Nine of twelve patients on follow-up had good voluntary bowel movements. Of the three patients who had grade I soiling two had recto-prostatic urethral fistula. No patient had constipation. All patients had good urinary stream. Conclusions: Repair of high ARM in male neonates with a well descended rectum is feasible without significant morbidity and good continence.

  19. Sagittal plane position of the functional joint centre of prosthetic foot/ankle mechanisms.

    Science.gov (United States)

    Rusaw, David; Ramstrand, Nerrolyn

    2010-08-01

    The use of motion analysis techniques in amputee rehabilitation often utilizes kinematic data from the prosthetic limb. A problem with methods currently used is that the joint positions of the prosthetic ankle are assumed to be in the same position as that of an intact ankle. The aim of this study was to identify both traditional anatomical joint centres as well as functional joint centres in a selection of commonly used prosthetic feet. These coordinates were then compared across feet and compared to the contralateral intact ankle joint. Six prosthetic feet were fit to a unilateral trans-tibial amputee on two separate occasions. The subject's intact limb was used as a control. Three-dimensional kinematics were collected to determine the sagittal position of the functional joint centre for the feet investigated. None of the prosthetic feet had a functional joint centre that was within the 95% CI for that of an intact ankle (both x- and y-coordinate position), nor any of the other prosthetic feet investigated. The repeatability of the method was found to be adequate, with 95% CI of the difference (test-retest) of the prosthetic feet similar to that for the intact ankle and within clinically accepted levels of variability. The motion of the prosthetic feet tested is clearly different from that of an intact ankle. Kinematic methods that assume ankle constraints based on an intact ankle are subject to systematic error as this does not reflect the real motion of the prosthetic foot. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  20. Sagittal spinopelvic parameters in children with achondroplasia: identification of 2 distinct groups.

    Science.gov (United States)

    Karikari, Isaac O; Mehta, Ankit I; Solakoglu, Can; Bagley, Carlos A; Ain, Michael C; Gottfried, Oren N

    2012-07-01

    Spinopelvic parameters in children with achondroplasia have not been described. Because they observed a unique sagittal spinopelvic phenotype in some achondroplastic children with very horizontal sacrums, the authors sought to quantify the spinopelvic parameters in a pediatric patient population. A retrospective review was performed to identify all children (age range 1 month-10 years) with a diagnosis of achondroplasia between 2004 and 2009. Clinical and radiographic data were analyzed for age, sex, lumbar lordosis (LL), thoracic kyphosis (TK), thoracolumbar kyphosis (TLK), sacral slope (SS), pelvic tilt (PT), and pelvic incidence (PI). Differences among these variables were analyzed using a 2-tailed, unpaired Student t-test. Forty children, 23 males and 17 females, with achondroplasia were identified during the study period. The mean age was 2.6 years. Two groups of patients were identified based on PT (that is, negative or positive tilt and horizontal or not horizontal sacrum). A negative PT was identified in all children with an extremely horizontal sacrum. Seventeen children had a negative PT (mean -16.6°), and the mean parameters in this group were 65.4° for LL, 31.7° for TLK, 18.5° for TK, 43.3° for SS, and 26.4° for PI. Twenty-three children had a positive PT (mean 17.9°), and the mean parameters in this group were 53.4° for LL, 41.5° for TLK, 9.6° for TK, 30.8° for SS, and 43.8° for PI. A statistically significant difference was observed for LL (p = 0.01), TLK (p = 0.05), SS (p = 0.006), PT (p = 0.006), and PI (0.0002). Spinopelvic parameters in achondroplasia are potentially dichotomous. The future implications of this observation are not known and will need to be explored in future long-term studies that follow pediatric patients with achondroplasia through adulthood.

  1. A new model to produce sagittal plane rotational induced diffuse axonal injuries

    Directory of Open Access Journals (Sweden)

    Johan eDavidsson

    2011-06-01

    Full Text Available A new in vivo animal model that produces diffuse brain injuries (DBI in sagittal plane rearward rotational acceleration has been developed. In this model, the skull of an anesthetized adult rat is tightly secured to a rotating bar. During trauma, the bar is impacted by a striker that causes the bar and the animal head to rotate rearward; the acceleration phase last 0.4 ms and is followed by a rotation at constant speed and a gentle deceleration when the bar makes contact with a padded stop. The total head angle change is less than 30 degrees. By adjusting the air pressure in the rifle used to accelerate the striker, resulting rotational acceleration between 0.3 and 2.1 Mrad/s2 can be produced.Numerous combinations of trauma levels, post-trauma survival times, brain and serum retrieval and tissue preparation techniques were adopted to characterise this new model. The trauma caused subdural bleedings in animals exposed to severe trauma. Staining brain tissue with β-Amyloid Precursor Protein antibodies and FD Neurosilver that detect degenerating axons revealed wide spread axonal injuries (AI in the corpus callosum, the border between the corpus callosum and cortex and in tracts in the brain stem. The observed AI:s were apparent only when the rotational acceleration level was moderate and above. On the contrary, only limited signs of contusion injuries were observed following trauma. S100 serum analyses indicate that blood vessel and glia cell injuries occur following moderate levels of trauma despite the absence of obvious BBB injuries. We conclude that this rotational trauma model is capable of producing graded axonal injury, is repeatable and produces limited other types of traumatic brain injuries (TBI and as such is useful in the study of injury biomechanics, diagnostics and treatment strategies following diffuse axonal injury (DAI.

  2. A new model to produce sagittal plane rotational induced diffuse axonal injuries.

    Science.gov (United States)

    Davidsson, Johan; Risling, Marten

    2011-01-01

    A new in vivo animal model that produces diffuse brain injuries in sagittal plane rearward rotational acceleration has been developed. In this model, the skull of an anesthetized adult rat is tightly secured to a rotating bar. During trauma, the bar is impacted by a striker that causes the bar and the animal head to rotate rearward; the acceleration phase last 0.4 ms and is followed by a rotation at constant speed and a gentle deceleration when the bar makes contact with a padded stop. The total head angle change is less than 30°. By adjusting the air pressure in the rifle used to accelerate the striker, resulting rotational acceleration between 0.3 and 2.1 Mrad/s(2) can be produced. Numerous combinations of trauma levels, post-trauma survival times, brain and serum retrieval, and tissue preparation techniques were adopted to characterize this new model. The trauma caused subdural bleedings in animals exposed to severe trauma. Staining brain tissue with β-Amyloid Precursor Protein antibodies and FD Neurosilver that detect degenerating axons revealed wide spread axonal injuries (AI) in the corpus callosum, the border between the corpus callosum and cortex and in tracts in the brain stem. The observed AIs were apparent only when the rotational acceleration level was moderate and above. On the contrary, only limited signs of contusion injuries were observed following trauma. Macrophage invasions, glial fibrillary acidic protein redistribution or hypertrophy, and blood brain barrier (BBB) changes were unusual. S100 serum analyses indicate that blood vessel and glia cell injuries occur following moderate levels of trauma despite the absence of obvious BBB injuries. We conclude that this rotational trauma model is capable of producing graded axonal injury, is repeatable and produces limited other types of traumatic brain injuries and as such is useful in the study of injury biomechanics, diagnostics, and treatment strategies following diffuse axonal injury.

  3. Sagittal abdominal diameter shows better correlation with cardiovascular risk factors than waist circumference and BMI.

    Science.gov (United States)

    de Souza, Natalia Cavalheri; de Oliveira, Erick Prado

    2013-01-01

    Obesity (abdominal adiposity) is a risk factor for cardiovascular diseases and the most used methods to measure the adiposity are body mass index (BMI), waist circumference (WC), and sagittal abdominal diameter (SAD). To correlate BMI, WC, and SAD with biochemical parameters and blood pressure in adults. A non-experimental exploratory/descriptive and cross sectional study was developed and it was assessed 133 subjects (59 men and 74 women) aging between 18 and 87 years. It was registered the patients' weight (kg), height (m), BMI (kg/m(2)), WC (cm) and SAD (cm), and these parameters were correlated with glycemia, triglycerides, total cholesterol, HDL-c, LDL-c and blood pressure. After adjustment for gender and age, it was observed a positive correlation between SAD and systolic arterial blood pressure (r = 0.20), glycemia (r = 0.20), triglycerides (r = 0.32), LDL (r = 0.26), total cholesterol (TC) (r = 0.33), and a negative correlation with HDL-c (r = -0.21) (p correlation between WC and systolic arterial blood pressure (r = 0.14), triglycerides (r = 0.31), total cholesterol (r = 0.21), and a negative correlation with HDL-c (r = -0.24) (p correlation with systolic arterial blood pressure (r = 0.22), total cholesterol (r = 0.20), and triglycerides (r = 0.23) (p correlated with almost all the cardiovascular risk factors analyzed and it might be considered the best predictor of abdominal fat and cardiovascular risk.

  4. [Evaluation of the impact of sagittal spinal curvatures on musculoskeletal disorders in young people].

    Science.gov (United States)

    Zwierzchowska, Anna; Tuz, Jacek

    2018-01-01

    In Poland, about 85% of the population report low back pain (LBP) symptoms overall. Moreover, 70-80% of people aged below 20 have already experienced back pain. The primary cause of LBP is the loss of spinal lordosis, which initiates changes in geometry of the spine and has impact on limb arrangement. The aim of the study was to attempt to verify the relationship between the 2 main curvatures of the spine and its relation to symptoms in different parts of the musculoskeletal system, in a group of adults. It was assumed that hyperlordosis of the lumbar spine and misbalance of the thoraco-lumbar junction are risk factors for LBP. The study coverd 231 first-year students, (aged 19-21) of the University of Economics in Katowice. There were 103 men aged 19.5±0.8 years and 128 women aged 19.6±0.8 years. The students completed the Nordic Musculoskeletal Questionnaire (NMQ): 7 days (NMQ7) and 6 months (NMQ6). A Rippstein's plurimeter, was used to measure the angles of thoracic kyphosis (KTH) and lumbar lordosis (KLL). Cut of points was set at 30±5. The results indicate strong and very strong correlation (r = 0.6 and r = 0.8, p < 0.05) between the concave of the back and LBP, which may suggest the relationship between these symptoms and the increased lordosis. Postural defects in the sagittal plane may predict the occurrence of pain. The results of the study indicate a higher frequency of pain in people with a higher angle of lumbar lordosis. Med Pr 2018;69(1):29-36. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  5. Visuotactile interaction even in far sagittal space in older adults with decreased gait and balance functions.

    Science.gov (United States)

    Teramoto, Wataru; Honda, Keito; Furuta, Kento; Sekiyama, Kaoru

    2017-08-01

    Spatial proximity of signals from different sensory modalities is known to be a crucial factor in facilitating efficient multisensory processing in young adults. However, recent studies have demonstrated that older adults exhibit strong visuotactile interactions even when the visual stimuli were presented in a spatially disparate position from a tactile stimulus. This suggests that visuotactile peripersonal space differs between older and younger adults. In the present study, we investigated to what extent peripersonal space expands in the sagittal direction and whether this expansion was linked to the decline in sensorimotor functions in older adults. Vibrotactile stimuli were delivered either to the left or right index finger, while visual stimuli were presented at a distance of 5 cm (near), 37.5 cm (middle), or 70 cm (far) from each finger. The participants had to respond rapidly to a randomized sequence of unimodal (visual or tactile) and simultaneous visuotactile targets (i.e., a redundant target paradigm). Sensorimotor functions were independently assessed by the Timed Up and Go (TUG) and postural stability tests. Results showed that reaction times to the visuotactile bimodal stimuli were significantly faster than those to the unimodal stimuli, irrespective of age group [younger adults: 22.0 ± 0.6 years, older adults: 75.0 ± 3.3 years (mean ± SD)] and target distance. Of importance, a race model analysis revealed that the co-activation model (i.e., visuotactile multisensory integrative process) is supported in the far condition especially for older adults with relatively poor performance on the TUG or postural stability tests. These results suggest that aging can change visuotactile peripersonal space and that it may be closely linked to declines in sensorimotor functions related to gait and balance in older adults.

  6. Sensory contributions to stabilization of trunk posture in the sagittal plane.

    Science.gov (United States)

    van Dieën, Jaap H; van Drunen, Paul; Happee, Riender

    2018-03-21

    Trunk stabilization is required to control posture and movement during daily activities. Various sensory modalities, such as muscle spindles, Golgi tendon organs and the vestibular system, might contribute to trunk stabilization and our aim was to assess the contribution of these modalities to trunk stabilization. In 35 healthy subjects, upper-body sway was evoked by continuous unpredictable, force-controlled perturbations to the trunk in the anterior direction. Subjects were instructed to either 'maximally resist the perturbation' or to 'relax but remain upright' with eyes closed. Frequency response functions (FRFs) of admittance, the amount of movement per unit of force applied, and reflexes, the modulation of trunk extensor activity per unit of trunk displacement, were obtained. To these FRFs, we fitted physiological models, to estimate intrinsic trunk stiffness and damping, as well as feedback gains and delays. The different model versions were compared to assess which feedback loops contribute to trunk stabilization. Intrinsic stiffness and damping and muscle spindle (short-delay) feedback alone were sufficient to accurately describe trunk stabilization, but only with unrealistically low reflex delays. Addition of muscle spindle acceleration feedback or inhibitory Golgi tendon organ feedback yielded realistic delays and improved the model fit, with a significantly better model fit with acceleration feedback. Addition of vestibular feedback did not improve the model fit. In conclusion, muscle spindle feedback and intrinsic mechanical properties are sufficient to describe trunk stabilization in the sagittal plane under small mechanical perturbations, provided that muscle spindles encode acceleration in addition to velocity and position information. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Quantitative assessment of the superior sagittal sinus on unenhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fanous, Randy, E-mail: randy.fanous@gmail.co [University of Toronto, Department of Medical Imaging (Canada); Leung, Andrew; Karlik, Stephen [University of Western Ontario, Department of Diagnostic Radiology and Nuclear Medicine (Canada)

    2010-09-15

    Purpose: To determine the relationship between hemoglobin levels and attenuation measurements of the superior sagittal sinus (SSS) on unenhanced computed tomography (UECT). Secondly, to determine if SSS attenuation values are normally distributed such that measurements below and above certain thresholds are suggestive of pathology, such as anemia or acute venous thrombosis respectively. Methods: Institutional review board approval was obtained for retrospective review of adult patients having both an UECT head examination and a complete blood count within 24 h of the scan. A cohort of 151 consecutive patients formed the study sample (76 males and 75 females, 17-91 years of age with a mean of 61). The dorsal aspect of the SSS was divided into upper, middle and lower segments. Using freehand and circle region of interest (ROI) techniques, a total of six attenuation measurements were obtained from each patient. Next, statistical analyses were preformed to assess the correlation between Hgb levels and attenuation values, and distribution curves were plotted to assess the normal range of SSS attenuation measurements. Results: There is a moderate, yet statistically significant (p < 0.001), correlation between Hgb levels and attenuation values in upper, middle and lower segments of the SSS (r = 0.487, 0.497 and 0.533 respectively). Based on the calculated mean, median and mode, the attenuation values are normally distributed. When using the freehand ROI technique, the mean value is 50 Hounsfield Units (HU) with a standard deviation (SD) of 7.5. Attenuation values less than 2 SDs (35 HU) are highly suggestive of anemia (specificity and PPV = 100%). Conclusion: There is a moderate, yet statistically significant, correlation between Hgb levels and attenuation of the SSS on UECT. Furthermore, attenuation measurements of the SSS are normally distributed with a mean of 50 HU and a SD of 7.5. Therefore, quantitative assessment of the SSS may prove useful in the clinical practice

  8. Short incomplete sagittal fractures of the proximal phalanx in ten horses not used for racing.

    Science.gov (United States)

    Kuemmerle, Jan M; Auer, Jörg A; Rademacher, Nathalie; Lischer, Christoph J; Bettschart-Wolfensberger, Regula; Fürst, Anton E

    2008-02-01

    To describe short incomplete sagittal fractures of the proximal phalanx (type Ia P1 fractures) in horses not used for racing and report outcome. Retrospective study. Horses (n=10) with type Ia P1 fractures. Retrieved data of horses with type Ia P1 fractures were signalment, history and results of orthopedic examination. Radiographs were re-evaluated for position and length of the fracture line, presence of osteoarthritis or subchondral cystic lesions (SCL), periosteal new bone formation and subchondral sclerosis. Conservative treatment (n=4) included box confinement for 2 months followed by 1 month of hand walking. Surgical therapy (n=6) consisted of internal fixation by screws inserted in lag fashion in 5 horses. Concurrent SCL were debrided by curettage via a transcortical drilling approach. In 1 horse, only SCL curettage but not internal fixation was performed. Outcome was assessed on a clinical and radiographic follow-up examination in all horses. Mean follow-up time was 27 months (median, 13.5 months; range, 9 months to 9 years). All horses treated with internal fixation were sound at follow-up and had radiographic fracture healing. Of the 4 horses managed conservatively, 3 remained lame and only 1 horse had radiographic evidence of fracture healing. Catastrophic fracture propagation occurred in 2 horses not treated by internal fixation, 20 and 30 months after diagnosis, respectively. Horses with a type Ia P1 fracture treated surgically had a better outcome than those managed conservatively and lack of fracture healing seemingly increases the risk of later catastrophic fracture. Surgical repair of type Ia P1 fractures should be considered to optimize healing and return to athletic use.

  9. Dorsal Scaphoid Subluxation on Sagittal Magnetic Resonance Imaging as a Marker for Scapholunate Ligament Tear.

    Science.gov (United States)

    Meister, David W; Hearns, Krystle A; Carlson, Michelle G

    2017-09-01

    To evaluate the diagnostic utility of scaphoid dorsal subluxation on magnetic resonance imaging (MRI) as a predictor of scapholunate interosseous ligament (SLIL) tears and compare this with radiographic findings. Thirty-six MRIs were retrospectively reviewed: 18 with known operative findings of complete Geissler IV SLIL tears that were surgically repaired, and 18 MRIs performed for ulnar-sided wrist pain but no SLIL tear. Dorsal subluxation of the scaphoid was measured on the sagittal MRI cut, which demonstrated the maximum subluxation. Independent samples t tests were used to compare radiographic measurements of scapholunate (SL) gap, SL angle, and capitolunate/third metacarpal-lunate angles between the SLIL tear and the control groups and to compare radiographic measurements between wrists that had dorsal subluxation of the scaphoid and wrists that did not have dorsal subluxation. Interrater reliability of subluxation measurements on lateral radiographs and on MRI were calculated using kappa coefficients. Thirteen of 18 wrists with complete SLIL tears had greater than 10% dorsal subluxation of the scaphoid relative to the scaphoid facet. Average subluxation in this group was 34%. Four of 18 wrists with known SLIL tears had no subluxation. No wrists without SLIL tears (control group) had dorsal subluxation. The SL angle, capitolunate/third metacarpal-lunate angle and SL gap were greater in wrists that had dorsal subluxation of the scaphoid on MRI. Interrater reliability of measurements of dorsal subluxation of the scaphoid was superior on MRI than on lateral x-ray. An MRI demonstration of dorsal subluxation of the scaphoid, of as little as 10%, as a predictor of SLIL tear had a sensitivity of 72% and a specificity of 100%. The high positive predictive value indicates that the presence of dorsal subluxation accurately predicts SLIL tear. Diagnostic II. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. Sagittal tibiotalar translation and clinical outcomes in mobile and fixed-bearing total ankle replacement.

    Science.gov (United States)

    Usuelli, Federico G; Manzi, Luigi; Brusaferri, Giovanni; Neher, Robert E; Guelfi, Matteo; Maccario, Camilla

    2017-06-01

    Sagittal implant malalignment after total ankle replacement (TAR) has been considered to be a possible cause for premature implant failure. In a prior study, the change over time of the tibiotalar ratio (T-T ratio), which is the ratio between the posterior longitudinal talar length and the full longitudinal talar length, was assessed in 66 TARs where an unconstrained, mobile-bearing implant was implanted. The analysis documented an increase in the T-T ratio between 2 and 6 months post-surgery (on average from 34.6% to 37.2%). We hypothesized that this change might have been related to the presence of a mobile-bearing insert. In order to test our hypothesis, we designed a study to compare the translation of the talus in TARs performed with an unconstrained, mobile-bearing implant (designated the "Mobile ankle") and those performed with a semi-constrained, fixed-bearing implant (designated the "Fixed ankle"). The study included 71 consecutive patients (71 ankles) who underwent TAR with the Mobile ankle and 24 consecutive patients (24 ankles) who received the Fixed ankle from May 2011 to December 2014. Patients were assessed clinically and radiologically preoperatively (T 0 ), at 6 months (T 2 ) and 12 months (T 3 ) post-surgery. There was also a radiological assessment at 2 months post-surgery (T 1 ). The comparison of the T-T ratio between the two implant groups and over time indicated an interaction between time and group, therefore the changes of the T-T ratio over time were affected by the implant type factor (Pbearing interface. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  11. The impact of sagittal balance on clinical results after posterior interbody fusion for patients with degenerative spondylolisthesis: A Pilot study

    Directory of Open Access Journals (Sweden)

    Chung Sung-Soo

    2011-04-01

    Full Text Available Abstract Background Comparatively little is known about the relation between the sagittal vertical axis and clinical outcome in cases of degenerative lumbar spondylolisthesis. The objective of this study was to determine whether lumbar sagittal balance affects clinical outcomes after posterior interbody fusion. This series suggests that consideration of sagittal balance during posterior interbody fusion for degenerative spondylolisthesis can yield high levels of patient satisfaction and restore spinal balance Methods A retrospective study of clinical outcomes and a radiological review was performed on 18 patients with one or two level degenerative spondylolisthesis. Patients were divided into two groups: the patients without improvement in pelvic tilt, postoperatively (Group A; n = 10 and the patients with improvement in pelvic tilt postoperatively (Group B; n = 8. Pre- and postoperative clinical outcome surveys were administered to determine Visual Analogue Pain Scores (VAS and Oswestry disability index (ODI. In addition, we evaluated full spine radiographic films for pelvic tilt (PT, sacral slope (SS, pelvic incidence (PI, thoracic kyphosis (TK, lumbar lordosis (LL, sacrofemoral distance (SFD, and sacro C7 plumb line distance (SC7D Results All 18 patients underwent surgery principally for the relief of radicular leg pain and back pain. In groups A and B, mean preoperative VAS were 6.85 and 6.81, respectively, and these improved to 3.20 and 1.63 at last follow-up. Mean preoperative ODI were 43.2 and 50.4, respectively, and these improved to 23.6 and 18.9 at last follow-up. In spinopelvic parameters, no significant difference was found between preoperative and follow up variables except PT in Group A. However, significant difference was found between the preoperative and follows up values of PT, SS, TK, LL, and SFD/SC7D in Group B. Between parameters of group A and B, there is borderline significance on preoperative PT, preoperative LL and last

  12. Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study.

    Science.gov (United States)

    Erdem, Mehmet; Gulabi, Deniz; Cecen, Gultekin Sitki; Avci, Cem Coskun; Asci, Murat; Saglam, Fevzi

    2015-07-01

    One of the important factors in a successful arthroplasty is component alignment. The primary objective of this study was to determine whether the fibular shaft reference technique is beneficial for the tibial component position on the postoperative plain radiograph after total knee arthroplasty. A total of 42 patients between 2009 and 2011 were analysed retrospectively. The surgeon prepared the tibia using an extramedullary cutting guide and set the posterior tibial slope with respect to the fibular reference rod. In the postoperative radiographic measurements, a true anteroposterior and lateral radiograph of the lower leg covering the whole length of the tibia was used. Five patients were excluded as they did not meet the inclusion criteria, four patients were excluded due to improper radiographs and the study group was reduced to 33 patients and 35 knees. The mean preoperative tibiofibular angle was 2.1° ± 0.8°. The mean postoperative tibial sagittal angle measurements were 83.3° ± 1.4° (81°-86°). 33 (94 %) Knees gained the desired tibial sagittal angle within the desired alignment (5° ± 3°). The mean postoperative tibial coronal angle was 89.3° ± 1.5°. The tibial component coronal angle of two knees was more than 3 alignment from the neutral mechanical axis. The major clinical relevance of the technique described in the present study is cost-effectiveness, and it does not require any extra time or surgical equipment. This method can be used as an alternative choice for bulky extremities which is a cause of malalignment of the components. Retrospective case series, Level IV.

  13. Accelerator and transport line survey and alignment

    International Nuclear Information System (INIS)

    Ruland, R.E.

    1991-10-01

    This paper summarizes the survey and alignment processes of accelerators and transport lines and discusses the propagation of errors associated with these processes. The major geodetic principles governing the survey and alignment measurement space are introduced and their relationship to a lattice coordinate system shown. The paper continues with a broad overview about the activities involved in the step sequence from initial absolute alignment to final smoothing. Emphasis is given to the relative alignment of components, in particular to the importance of incorporating methods to remove residual systematic effects in surveying and alignment operations. Various approaches to smoothing used at major laboratories are discussed. 47 refs., 19 figs., 1 tab

  14. Aligning molecules with intense nonresonant laser fields

    DEFF Research Database (Denmark)

    Larsen, J.J.; Safvan, C.P.; Sakai, H.

    1999-01-01

    Molecules in a seeded supersonic beam are aligned by the interaction between an intense nonresonant linearly polarized laser field and the molecular polarizability. We demonstrate the general applicability of the scheme by aligning I2, ICl, CS2, CH3I, and C6H5I molecules. The alignment is probed...... by mass selective two dimensional imaging of the photofragment ions produced by femtosecond laser pulses. Calculations on the degree of alignment of I2 are in good agreement with the experiments. We discuss some future applications of laser aligned molecules....

  15. An interactive tool for CT volume rendering and sagittal plane-picking of the prostate for radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Jani, Ashesh B.; Pelizzari, Charles A.; Chen, George T.Y.; Grzezcszuk, Robert P.; Vijayakumar, Srinivasan

    1997-01-01

    Objective: Accurate and precise target volume and critical structure definition is a basic necessity in radiotherapy. The prostate, particularly the apex (an important potential site of recurrence in prostate cancer patients), is a challenging structure to define using any modality, including conventional axial CT. Invasive or expensive techniques, such as retrograde urethrography or MRI, could be avoided if localization of the prostate were possible using information already available on the planning CT. Our primary objective was to build a software tool to determine whether volume rendering and sagittal plane-picking, which are CT-based, noninvasive visualization techniques, were of utility in radiotherapy treatment planning for the prostate. Methods: Using AVS (Application Visualization System) on a Silicon Graphics Indigo 2 High Impact workstation, we have developed a tool that enables the clinician to efficiently navigate a CT volume and to use volume rendering and sagittal plane-picking to better define structures at any anatomic site. We applied the tool to the specific example of the prostate to compare the two visualization techniques with the current standard of axial CT. The prostate was defined on 80-slice CT scans (scanning thickness 4mm, pixel size 2mm x 2mm) of prostate cancer patients using axial CT images, volume-rendered CT images, and sagittal plane-picked images. Results: The navigation of the prostate using the different visualization techniques qualitatively demonstrated that the sagittal plane-picked images, and even more so the volume-rendered images, revealed the prostate (particularly the lower border) better in relationship to the surrounding regional anatomy (bladder, rectum, pelvis, and penile structures) than did the axial images. A quantitative comparison of the target volumes obtained by navigating using the different visualization techniques demonstrated that, when compared to the prostate volume defined on axial CT, a larger volume

  16. Effect of the increase in the height of lumbar disc space on facet joint articulation area in sagittal plane.

    Science.gov (United States)

    Liu, Jiayong; Ebraheim, Nabil A; Haman, Steven P; Shafiq, Qaiser; Karkare, Nakul; Biyani, Ashok; Goel, Vijay K; Woldenberg, Lee

    2006-04-01

    Computerized tomography (CT) of the lumbar spine cadaveric specimens was used to evaluate the effect of increasing the height of the disc space in the lumbar spine to the facet joint articulation in the sagittal plane. To show how the facet joint articulation is affected by increasing the height of the disc space in the lumbar spine. The Charité Artificial Disc (DePuy Spine, Inc., Raynham, MA) was successful in relieving low back pain in the majority of patients, yet there was still a significant number of patients who did not obtain pain relief, or their pain even worsened. The etiology of their pain is still not known. To our knowledge, no study has addressed the effect on the facet joints when the disc height is increased. CT images passing through the center of the L3-S1 facet joints (sagittal plane) were obtained from 15 cadaveric lumbar spine specimens. The articulation overlap of facet joints in sagittal plane from the L3 to S1 was measured. A 1-mm incremental increase to a total 5 mm in disc space height was performed to simulate the changes seen in disc replacement. The change in the facet joint articulation overlap in sagittal plane at normal and each displacement was then measured. There were 5 lumbar spine specimens dissected to validate the technique and standardize the measurements. Mean, percentages, and standard deviation values were calculated for all measured dimensions. No significant difference was found between the measurements on CT and gross specimens (P > 0.05). In 15 specimens, the mean facet joint articulation overlap on the sagittal plane was: 16.29 +/- 1.20 mm (left) and 16.22 +/- 1.16 (right) at the L3-L4 level; 17.81 +/- 1.18 mm (left) and 17.74 +/- 1.18 mm (right) at the L4-L5 level; and 18.18 +/- 1.18 mm (left) and 18.23 +/- 1.15 mm (right) at the L5-S1 level. There is no significant difference between the measured values on left and right sides (P > 0.05). Each 1-mm incremental increase in disc space at the L3-L4 level translated

  17. Alignment method for solar collector arrays

    Science.gov (United States)

    Driver, Jr., Richard B

    2012-10-23

    The present invention is directed to an improved method for establishing camera fixture location for aligning mirrors on a solar collector array (SCA) comprising multiple mirror modules. The method aligns the mirrors on a module by comparing the location of the receiver image in photographs with the predicted theoretical receiver image location. To accurately align an entire SCA, a common reference is used for all of the individual module images within the SCA. The improved method can use relative pixel location information in digital photographs along with alignment fixture inclinometer data to calculate relative locations of the fixture between modules. The absolute locations are determined by minimizing alignment asymmetry for the SCA. The method inherently aligns all of the mirrors in an SCA to the receiver, even with receiver position and module-to-module alignment errors.

  18. MEANS FOR DETERMINING CENTRIFUGE ALIGNMENT

    Science.gov (United States)

    Smith, W.Q.

    1958-08-26

    An apparatus is presented for remotely determining the alignment of a centrifuge. The centrifage shaft is provided with a shoulder, upon which two followers ride, one for detecting radial movements, and one upon the shoulder face for determining the axial motion. The followers are attached to separate liquid filled bellows, and a tube connects each bellows to its respective indicating gage at a remote location. Vibrations produced by misalignment of the centrifuge shaft are transmitted to the bellows, and tbence through the tubing to the indicator gage. This apparatus is particularly useful for operation in a hot cell where the materials handled are dangerous to the operating personnel.

  19. NON-ALIGNEMENT IN AFRICA

    OpenAIRE

    G. Jacobs

    2012-01-01

    The first indications to the Western world that African non-alignment had achieved conscious political form became apparent only in the late 1940's. This strand of thought within the tapestry of Africanism reached its zenith with the declarations of Kwame Nkrumah, Jomo Kenyatta and Julius Nyerere in the years after the Pan-African Congress in Manchester in 1945. The causes of the movement go back far beyond the first official expressions of an African solidarity in the 1940's. As a mature exp...

  20. Multiple sequence alignment accuracy and phylogenetic inference.

    Science.gov (United States)

    Ogden, T Heath; Rosenberg, Michael S

    2006-04-01

    Phylogenies are often thought to be more dependent upon the specifics of the sequence alignment rather than on the method of reconstruction. Simulation of sequences containing insertion and deletion events was performed in order to determine the role that alignment accuracy plays during phylogenetic inference. Data sets were simulated for pectinate, balanced, and random tree shapes under different conditions (ultrametric equal branch length, ultrametric random branch length, nonultrametric random branch length). Comparisons between hypothesized alignments and true alignments enabled determination of two measures of alignment accuracy, that of the total data set and that of individual branches. In general, our results indicate that as alignment error increases, topological accuracy decreases. This trend was much more pronounced for data sets derived from more pectinate topologies. In contrast, for balanced, ultrametric, equal branch length tree shapes, alignment inaccuracy had little average effect on tree reconstruction. These conclusions are based on average trends of many analyses under different conditions, and any one specific analysis, independent of the alignment accuracy, may recover very accurate or inaccurate topologies. Maximum likelihood and Bayesian, in general, outperformed neighbor joining and maximum parsimony in terms of tree reconstruction accuracy. Results also indicated that as the length of the branch and of the neighboring branches increase, alignment accuracy decreases, and the length of the neighboring branches is the major factor in topological accuracy. Thus, multiple-sequence alignment can be an important factor in downstream effects on topological reconstruction.

  1. Reticular alignment: A progressive corner-cutting method for multiple sequence alignment

    Directory of Open Access Journals (Sweden)

    Novák Ádám

    2010-11-01

    Full Text Available Abstract Background In this paper, we introduce a progressive corner cutting method called Reticular Alignment for multiple sequence alignment. Unlike previous corner-cutting methods, our approach does not define a compact part of the dynamic programming table. Instead, it defines a set of optimal and suboptimal alignments at each step during the progressive alignment. The set of alignments are represented with a network to store them and use them during the progressive alignment in an efficient way. The program contains a threshold parameter on which the size of the network depends. The larger the threshold parameter and thus the network, the deeper the search in the alignment space for better scored alignments. Results We implemented the program in the Java programming language, and tested it on the BAliBASE database. Reticular Alignment can outperform ClustalW even if a very simple scoring scheme (BLOSUM62 and affine gap penalty is implemented and merely the threshold value is increased. However, this set-up is not sufficient for outperforming other cutting-edge alignment methods. On the other hand, the reticular alignment search strategy together with sophisticated scoring schemes (for example, differentiating gap penalties for hydrophobic and hydrophylic amino acids overcome FSA and in some accuracy measurement, even MAFFT. The program is available from http://phylogeny-cafe.elte.hu/RetAlign/ Conclusions Reticular alignment is an efficient search strategy for finding accurate multiple alignments. The highest accuracy achieved when this searching strategy is combined with sophisticated scoring schemes.

  2. Estimation of Vertical Ground Reaction Forces and Sagittal Knee Kinematics During Running Using Three Inertial Sensors.

    Science.gov (United States)

    Wouda, Frank J; Giuberti, Matteo; Bellusci, Giovanni; Maartens, Erik; Reenalda, Jasper; van Beijnum, Bert-Jan F; Veltink, Peter H

    2018-01-01

    Analysis of running mechanics has traditionally been limited to a gait laboratory using either force plates or an instrumented treadmill in combination with a full-body optical motion capture system. With the introduction of inertial motion capture systems, it becomes possible to measure kinematics in any environment. However, kinetic information could not be provided with such technology. Furthermore, numerous body-worn sensors are required for a full-body motion analysis. The aim of this study is to examine the validity of a method to estimate sagittal knee joint angles and vertical ground reaction forces during running using an ambulatory minimal body-worn sensor setup. Two concatenated artificial neural networks were trained (using data from eight healthy subjects) to estimate the kinematics and kinetics of the runners. The first artificial neural network maps the information (orientation and acceleration) of three inertial sensors (placed at the lower legs and pelvis) to lower-body joint angles. The estimated joint angles in combination with measured vertical accelerations are input to a second artificial neural network that estimates vertical ground reaction forces. To validate our approach, estimated joint angles were compared to both inertial and optical references, while kinetic output was compared to measured vertical ground reaction forces from an instrumented treadmill. Performance was evaluated using two scenarios: training and evaluating on a single subject and training on multiple subjects and evaluating on a different subject. The estimated kinematics and kinetics of most subjects show excellent agreement (ρ>0.99) with the reference, for single subject training. Knee flexion/extension angles are estimated with a mean RMSE forces are estimated with a mean RMSE force, loading rate and maximal knee flexion during stance were compared, however, no significant differences were found. With multiple subject training the accuracy of estimating discrete and

  3. Trombosis del seno sagital en un neonato Sagittal sinus thrombosis in a newborn

    Directory of Open Access Journals (Sweden)

    Lisett Hernández León

    2012-12-01

    Full Text Available La trombosis de los senos venosos durales es una rara y devastadora enfermedad. Se presenta generalmente en mujeres y ancianos, y no es frecuente en niños, aunque se reconoce ya como una causa de morbilidad y mortalidad en la población pediátrica. Se han reportado pocos casos en el mundo de neonatos afectados por esta entidad, en su mayoría fatales e insuficientemente investigados. A continuación se presenta el caso de un recién nacido con una trombosis del seno sagital que sobrevivió. Los factores predisponentes para la aparición de la enfermedad en este caso fueron la asfixia neonatal, la deshidratación severa unida al uso de una línea venosa central, y la inmovilización prolongada. Aunque la TAC contrastada no es el estudio ideal para su diagnóstico, permitió realizarlo oportunamente en este caso. El tratamiento temprano con anticoagulantes permitió una rápida recuperación y favoreció la recanalización venosa del seno involucrado. Hasta el momento no se han detectado secuelas neurológicas y el paciente tiene buen desarrollo psicomotor.Dural venous sinus thrombosis is a rare devastating disease. It is generally found in females and old people, but is infrequent in children; however, it is already recognized as a morbidity and mortality cause in the pediatric population. Few cases of newborns with this disease have been reported worldwide; most of them were poorly studied and had fatal outcomes. Here is the presentation of a newborn with sagittal sinus thrombosis, who managed to survive. The predisposing factors for the disease were neonatal asphyxia, severe dehydration together with the use of central venous line and extended immobilization. Although contrast CAT is not the ideal study, it helped to promptly arrive at the right diagnosis in this case. The early treatment based on anticoagulants allowed rapid recovery and facilitated venous retaking of the involved venous sinus. No neurological sequels have been so far

  4. Estimation of Vertical Ground Reaction Forces and Sagittal Knee Kinematics During Running Using Three Inertial Sensors

    Directory of Open Access Journals (Sweden)

    Frank J. Wouda

    2018-03-01

    Full Text Available Analysis of running mechanics has traditionally been limited to a gait laboratory using either force plates or an instrumented treadmill in combination with a full-body optical motion capture system. With the introduction of inertial motion capture systems, it becomes possible to measure kinematics in any environment. However, kinetic information could not be provided with such technology. Furthermore, numerous body-worn sensors are required for a full-body motion analysis. The aim of this study is to examine the validity of a method to estimate sagittal knee joint angles and vertical ground reaction forces during running using an ambulatory minimal body-worn sensor setup. Two concatenated artificial neural networks were trained (using data from eight healthy subjects to estimate the kinematics and kinetics of the runners. The first artificial neural network maps the information (orientation and acceleration of three inertial sensors (placed at the lower legs and pelvis to lower-body joint angles. The estimated joint angles in combination with measured vertical accelerations are input to a second artificial neural network that estimates vertical ground reaction forces. To validate our approach, estimated joint angles were compared to both inertial and optical references, while kinetic output was compared to measured vertical ground reaction forces from an instrumented treadmill. Performance was evaluated using two scenarios: training and evaluating on a single subject and training on multiple subjects and evaluating on a different subject. The estimated kinematics and kinetics of most subjects show excellent agreement (ρ>0.99 with the reference, for single subject training. Knee flexion/extension angles are estimated with a mean RMSE <5°. Ground reaction forces are estimated with a mean RMSE < 0.27 BW. Additionaly, peak vertical ground reaction force, loading rate and maximal knee flexion during stance were compared, however, no significant

  5. Contributions of individual muscles to the sagittal- and frontal-plane angular accelerations of the trunk in walking.

    Science.gov (United States)

    Klemetti, Rudolf; Steele, Katherine M; Moilanen, Petro; Avela, Janne; Timonen, Jussi

    2014-07-18

    This study was conducted to analyze the unimpaired control of the trunk during walking. Studying the unimpaired control of the trunk reveals characteristics of good control. These characteristics can be pursued in the rehabilitation of impaired control. Impaired control of the trunk during walking is associated with aging and many movement disorders. This is a concern as it is considered to increase fall risk. Muscles that contribute to the trunk control in normal walking may also contribute to it under perturbation circumstances, attempting to prevent an impending fall. Knowledge of such muscles can be used to rehabilitate impaired control of the trunk. Here, angular accelerations of the trunk induced by individual muscles, in the sagittal and frontal planes, were calculated using 3D muscle-driven simulations of seven young healthy subjects walking at free speed. Analysis of the simulations demonstrated that the abdominal and back muscles displayed large contributions throughout the gait cycle both in the sagittal and frontal planes. Proximal lower-limb muscles contributed more than distal muscles in the sagittal plane, while both proximal and distal muscles showed large contributions in the frontal plane. Along with the stance-limb muscles, the swing-limb muscles also exhibited considerable contribution. The gluteus medius was found to be an important individual frontal-plane control muscle; enhancing its function in pathologies could ameliorate gait by attenuating trunk sway. In addition, since gravity appreciably accelerated the trunk in the frontal plane, it may engender excessive trunk sway in pathologies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. The significance of faint visualization of the superior sagittal sinus in brain scintigraphy for the diagnosis of brain death

    International Nuclear Information System (INIS)

    Bisset, R.; Sfakianakis, G.; Ihmedian, I.; Holzman, B.; Curless, R.; Serafini, A.

    1985-01-01

    Brain death is associated with cessation of blood flow to the brain. Tc-99m brain flow studies are used as a laboratory confirmatory test for the establishment of the diagnosis of brain death. Criteria for the diagnosis of cessation of blood flow to the brain are 1) visualization of carotid artery activity in the neck of the patient and 2) no visualization of activity in the distribution of the anterior and middle cerebral arteries. The authors noticed that in a significant number of patients, although there was no visualization of arterial blood flow to the brain the static images demonstrated faint accumulation of activity in the region of the superior sagittal sinus (SSS). In a four year period 212 brain flow studies were performed in 154 patients for diagnosis of brain death; of them 137 studies (65%) showed no evidence of arterial flow. In 103 out of the 137 studies (75%) there was no visualization of the SSS; in the remaining 34 studies (3l patients) however three patterns of faint activity attributed to partial and or faint visualization of the SSS could be recognized at the midline of the immediate anterior static view: a) linear from the cranial vault floor up b) disk shaped at the apex of the vault and c) disk shaped at the apex tailing caudad. All of the 3l patients in this group satisfied brain death criteria within four days of the last study which showed faint visualization of the superior sagittal sinus. The authors conclude that even in the presence of a faint visualization of the superior sagittal sinus on static post brain flow scintigraphy, the diagnosis of cessation of blood flow to the brain can be made if there is no evidence of arterial blood flow

  7. Correlation Between Lumbopelvic and Sagittal Parameters and Health-Related Quality of Life in Adults With Lumbosacral Spondylolisthesis.

    Science.gov (United States)

    Gussous, Yazeed; Theologis, Alexander A; Demb, Joshua B; Tangtiphaiboontana, Jennifer; Berven, Sigurd

    2018-02-01

    Secondary analysis of prospective, multicenter data. To evaluate impact of sagittal parameters on health-related quality of life (HRQoL) in adults with lumbosacral spondylolisthesis. Adults with unoperated lumbosacral spondylolisthesis were identified in the Spinal Deformity Study Group database. Pearson's correlations were calculated between SF-12 (Short Form-12)/Scoliosis Research Society-30 (SRS-30) scores and radiographic parameters (C7 sagittal vertical axis [SVA] deviation, T1 pelvic angle, pelvic tilt [PT], pelvic incidence, sacral slope, slip angle, Meyerding slip grade, Labelle classification). Main effects linear regression models measured association between individual health status measures and individual radiographic predictor variables. Forty-five patients were analyzed (male, 15; female, 30; average age 40.5 ± 18.7 years; 14 low-grade, 31 high-grade). For low-grade slips, SVA had strong negative correlations with SF-12 mental component score (MCS), SRS-30 appearance, mental, and satisfaction domains ( r = -0.57, r = -0.60, r = -0.58, r = -0.53, respectively; P grade slips, slip angle had a moderate negative correlation with SF-12 MCS ( r = -0.36; P = .05) and SVA had strong negative correlations with SF-12 physical component score (PCS), SRS-30 appearance and activity domains ( r = -0.48, r = -0.48, r = -0.45; P point decrease in SRS appearance, 0.05-point decrease in SRS activity, 0.06-point decrease in SRS satisfaction, and 0.04-point decrease in SRS total score ( P grade slips. Improvement of sagittal parameters is an important goal of surgery for adults with lumbosacral spondylolisthesis.

  8. A cross-species alignment tool (CAT)

    DEFF Research Database (Denmark)

    Li, Heng; Guan, Liang; Liu, Tao

    2007-01-01

    sensitive methods which are usually applied in aligning inter-species sequences. RESULTS: Here we present a new algorithm called CAT (for Cross-species Alignment Tool). It is designed to align mRNA sequences to mammalian-sized genomes. CAT is implemented using C scripts and is freely available on the web......BACKGROUND: The main two sorts of automatic gene annotation frameworks are ab initio and alignment-based, the latter splitting into two sub-groups. The first group is used for intra-species alignments, among which are successful ones with high specificity and speed. The other group contains more...... at http://xat.sourceforge.net/. CONCLUSIONS: Examined from different angles, CAT outperforms other extant alignment tools. Tested against all available mouse-human and zebrafish-human orthologs, we demonstrate that CAT combines the specificity and speed of the best intra-species algorithms, like BLAT...

  9. Changing Sagittal-Plane Landing Styles to Modulate Impact and Tibiofemoral Force Magnitude and Directions Relative to the Tibia

    Science.gov (United States)

    Shimokochi, Yohei; Ambegaonkar, Jatin P.; Meyer, Eric G.

    2016-01-01

    Context: Ground reaction force (GRF) and tibiofemoral force magnitudes and directions have been shown to affect anterior cruciate ligament loading during landing. However, the kinematic and kinetic factors modifying these 2 forces during landing are unknown. Objective: To clarify the intersegmental kinematic and kinetic links underlying the alteration of the GRF and tibiofemoral force vectors secondary to changes in the sagittal-plane body position during single-legged landing. Design: Crossover study. Setting: Laboratory. Patients or Other Participants: Twenty recreationally active participants (age = 23.4 ± 3.6 years, height = 171.0 ± 9.4 cm, mass = 73.3 ± 12.7 kg). Intervention(s): Participants performed single-legged landings using 3 landing styles: self-selected landing (SSL), body leaning forward and landing on the toes (LFL), and body upright with flat-footed landing (URL). Three-dimensional kinetics and kinematics were recorded. Main Outcome Measure(s): Sagittal-plane tibial inclination and knee-flexion angles, GRF magnitude and inclination angles relative to the tibia, and proximal tibial forces at peak tibial axial forces. Results: The URL resulted in less time to peak tibial axial forces, smaller knee-flexion angles, and greater magnitude and a more anteriorly inclined GRF vector relative to the tibia than did the SSL. These changes led to the greatest peak tibial axial and anterior shear forces in the URL among the 3 landing styles. Conversely, the LFL resulted in longer time to peak tibial axial forces, greater knee-flexion angles, and reduced magnitude and a more posteriorly inclined GRF vector relative to the tibia than the SSL. These changes in LFL resulted in the lowest peak tibial axial and largest posterior shear forces among the 3 landing styles. Conclusions: Sagittal-plane intersegmental kinematic and kinetic links strongly affected the magnitude and direction of GRF and tibiofemoral forces during the impact phase of single-legged landing

  10. Distributed Interference Alignment with Low Overhead

    OpenAIRE

    Ma, Yanjun; Li, Jiandong; Chen, Rui

    2011-01-01

    Based on closed-form interference alignment (IA) solutions, a low overhead distributed interference alignment (LOIA) scheme is proposed in this paper for the $K$-user SISO interference channel, and extension to multiple antenna scenario is also considered. Compared with the iterative interference alignment (IIA) algorithm proposed by Gomadam et al., the overhead is greatly reduced. Simulation results show that the IIA algorithm is strictly suboptimal compared with our LOIA algorithm in the ov...

  11. The Practical Challenges of Interference Alignment

    OpenAIRE

    Ayach, Omar El; Peters, Steven W.; Heath Jr, Robert W.

    2012-01-01

    Interference alignment (IA) is a revolutionary wireless transmission strategy that reduces the impact of interference. The idea of interference alignment is to coordinate multiple transmitters so that their mutual interference aligns at the receivers, facilitating simple interference cancellation techniques. Since IA's inception, researchers have investigated its performance and proposed improvements, verifying IA's ability to achieve the maximum degrees of freedom (an approximation of sum ca...

  12. Clear aligners generations and orthodontic tooth movement.

    Science.gov (United States)

    Hennessy, Joe; Al-Awadhi, Ebrahim A

    2016-03-01

    Clear aligner technology has evolved over the last 15 years, with these appliances continually being modified to increase the range of tooth movements that they can achieve. However, there is very little clinical research available to show how these appliances achieve their results. This article describes the different generations of clear aligners that are available and highlights their use. However, until more clinical research becomes available, aligners cannot be routinely prescribed as an effective alternative to fixed labial appliances.

  13. Triangular Alignment (TAME). A Tensor-based Approach for Higher-order Network Alignment

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadi, Shahin [Purdue Univ., West Lafayette, IN (United States); Gleich, David F. [Purdue Univ., West Lafayette, IN (United States); Kolda, Tamara G. [Sandia National Laboratories (SNL-CA), Livermore, CA (United States); Grama, Ananth [Purdue Univ., West Lafayette, IN (United States)

    2015-11-01

    Network alignment is an important tool with extensive applications in comparative interactomics. Traditional approaches aim to simultaneously maximize the number of conserved edges and the underlying similarity of aligned entities. We propose a novel formulation of the network alignment problem that extends topological similarity to higher-order structures and provide a new objective function that maximizes the number of aligned substructures. This objective function corresponds to an integer programming problem, which is NP-hard. Consequently, we approximate this objective function as a surrogate function whose maximization results in a tensor eigenvalue problem. Based on this formulation, we present an algorithm called Triangular AlignMEnt (TAME), which attempts to maximize the number of aligned triangles across networks. We focus on alignment of triangles because of their enrichment in complex networks; however, our formulation and resulting algorithms can be applied to general motifs. Using a case study on the NAPABench dataset, we show that TAME is capable of producing alignments with up to 99% accuracy in terms of aligned nodes. We further evaluate our method by aligning yeast and human interactomes. Our results indicate that TAME outperforms the state-of-art alignment methods both in terms of biological and topological quality of the alignments.

  14. The art of editing RNA structural alignments

    DEFF Research Database (Denmark)

    Andersen, Ebbe Sloth

    2014-01-01

    Manual editing of RNA structural alignments may be considered more art than science, since it still requires an expert biologist to take multiple levels of information into account and be slightly creative when constructing high-quality alignments. Even though the task is rather tedious, it is re......Manual editing of RNA structural alignments may be considered more art than science, since it still requires an expert biologist to take multiple levels of information into account and be slightly creative when constructing high-quality alignments. Even though the task is rather tedious...

  15. Advancements of vertically aligned liquid crystal displays.

    Science.gov (United States)

    Kumar, Pankaj; Jaggi, Chinky; Sharma, Vandna; Raina, Kuldeep Kumar

    2016-02-01

    This review describes the recent advancements in the field of the vertical aligned (VA) liquid crystal displays. The process and formation of different vertical alignment modes such as conventional VA, patterned VA, multi-domain VA, and polymer stabilised VA etc are widely discussed. Vertical alignment of liquid crystal due to nano particle dispersion in LC host, bifunctional PR-SAM formed by silane coupling reaction to oxide surfaces, azo dye etc., are also highlighted and discussed. Overall, the article highlights the advances in the research of vertical aligned liquid crystal in terms of their scientific and technological aspects. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Scintillation counter: photomultiplier tube alignment

    International Nuclear Information System (INIS)

    Olson, R.E.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into the sample receiving zone. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (auth)

  17. Fiscal State-citizen Alignment

    DEFF Research Database (Denmark)

    Celik, Tim Holst

    2016-01-01

    , this article maps out four episodes of sovereign fiscalism, namely, debt-taking in the Italian city-states, the making of the absolutist tax/fiscal state, the eighteenth/nineteenth century elaboration of the economic citizen, and the postwar era of managed capitalism. Finally, it applies this framework......The 2008 crisis ended the growth bubble of the 2000s, which Organisation for Economic Co-operation and Development (OECD) governments facilitated through the normative/political-regulatory promotion of household indebtedness. Historically contextualizing this state-citizen relationship...... to the 2008 crisis and the larger post-1970s politico-economic constellation. The crisis can be perceived as a particular articulation of an age-old state-household dynamic—a dialectical alignment of the mode of fiscal state-crafting with the ethos of the state-citizen nexus—characterized by a heightened...

  18. Heuristics for multiobjective multiple sequence alignment.

    Science.gov (United States)

    Abbasi, Maryam; Paquete, Luís; Pereira, Francisco B

    2016-07-15

    Aligning multiple sequences arises in many tasks in Bioinformatics. However, the alignments produced by the current software packages are highly dependent on the parameters setting, such as the relative importance of opening gaps with respect to the increase of similarity. Choosing only one parameter setting may provide an undesirable bias in further steps of the analysis and give too simplistic interpretations. In this work, we reformulate multiple sequence alignment from a multiobjective point of view. The goal is to generate several sequence alignments that represent a trade-off between maximizing the substitution score and minimizing the number of indels/gaps in the sum-of-pairs score function. This trade-off gives to the practitioner further information about the similarity of the sequences, from which she could analyse and choose the most plausible alignment. We introduce several heuristic approaches, based on local search procedures, that compute a set of sequence alignments, which are representative of the trade-off between the two objectives (substitution score and indels). Several algorithm design options are discussed and analysed, with particular emphasis on the influence of the starting alignment and neighborhood search definitions on the overall performance. A perturbation technique is proposed to improve the local search, which provides a wide range of high-quality alignments. The proposed approach is tested experimentally on a wide range of instances. We performed several experiments with sequences obtained from the benchmark database BAliBASE 3.0. To evaluate the quality of the results, we calculate the hypervolume indicator of the set of score vectors returned by the algorithms. The results obtained allow us to identify reasonably good choices of parameters for our approach. Further, we compared our method in terms of correctly aligned pairs ratio and columns correctly aligned ratio with respect to reference alignments. Experimental results show

  19. Precision and accuracy of age estimates obtained from anal fin spines, dorsal fin spines, and sagittal otoliths for known-age largemouth bass

    Science.gov (United States)

    Klein, Zachary B.; Bonvechio, Timothy F.; Bowen, Bryant R.; Quist, Michael C.

    2017-01-01

    Sagittal otoliths are the preferred aging structure for Micropterus spp. (black basses) in North America because of the accurate and precise results produced. Typically, fisheries managers are hesitant to use lethal aging techniques (e.g., otoliths) to age rare species, trophy-size fish, or when sampling in small impoundments where populations are small. Therefore, we sought to evaluate the precision and accuracy of 2 non-lethal aging structures (i.e., anal fin spines, dorsal fin spines) in comparison to that of sagittal otoliths from known-age Micropterus salmoides (Largemouth Bass; n = 87) collected from the Ocmulgee Public Fishing Area, GA. Sagittal otoliths exhibited the highest concordance with true ages of all structures evaluated (coefficient of variation = 1.2; percent agreement = 91.9). Similarly, the low coefficient of variation (0.0) and high between-reader agreement (100%) indicate that age estimates obtained from sagittal otoliths were the most precise. Relatively high agreement between readers for anal fin spines (84%) and dorsal fin spines (81%) suggested the structures were relatively precise. However, age estimates from anal fin spines and dorsal fin spines exhibited low concordance with true ages. Although use of sagittal otoliths is a lethal technique, this method will likely remain the standard for aging Largemouth Bass and other similar black bass species.

  20. Treatment and post-treatment effects of facemask therapy on the sagittal pharyngeal dimensions in Class III subjects.

    Science.gov (United States)

    Baccetti, Tiziano; Franchi, Lorenzo; Mucedero, Manuela; Cozza, Paola

    2010-06-01

    The purpose of this cephalometric study was to analyse the treatment and post-treatment craniofacial effects of a facemask (FM) combined with a bite block (BB) with specific regard to the sagittal pharyngeal dimensions in subjects with a Class III malocclusion when compared with an untreated Class III control group. The FM/BB group (22 subjects, 12 females and 10 males) had a mean age pre-treatment (T1) of 8.9 +/- 1.5 years, at the end of active treatment (T2) of 10.5 +/- 1.3 years, and post-treatment (T3) of 12.6 +/- 1.9 years. The treated group was compared with a control group of 14 subjects (6 females and 8 males) with untreated Class III malocclusions that matched the FM/BB group as to age at T1, T2, and T3, observation periods and skeletal maturation. Comparisons of the T2-T1 and T3-T1 changes between the two groups were analysed with the Mann-Whitney test. Significant favourable skeletal changes in the maxilla and mandible were observed in the treated group both after Ts2 and T3. No significant short- or long-term changes in the sagittal oropharyngeal and nasopharyngeal airway dimensions were induced by maxillary protraction in subjects with a Class III malocclusion when compared with untreated controls.

  1. The MRI findings of meniscal root tear of the medial meniscus: emphasis on coronal, sagittal and axial images.

    Science.gov (United States)

    Choi, Sang-Hee; Bae, Sooho; Ji, Suk Kyeong; Chang, Moon Jong

    2012-10-01

    The purpose of this study was to evaluate the accuracy of the characteristic magnetic resonance imaging (MRI) findings of medial meniscal root tear in the coronal, sagittal and axial planes. Thirty arthroscopically diagnosed patients who had undergone preoperative knee MRI were included in this study. They were compared to 30 age-matched patients with medial meniscus tears without root tears. The findings used for imaging analysis were as follows: the radial tear on the meniscal root of the medial meniscus in the axial plane, the presence of the truncation sign in the coronal plane and the ghost meniscus sign in the sagittal plane. Meniscal extrusion in the coronal plane was also evaluated. All the MRI findings of both groups were statistically analyzed. All the findings were more frequently found in the root tear group than those in the control group (P meniscal root tear were characteristic as compared with the control group. Radial tear in the axial plane also showed similar diagnostic accuracy as that seen in the other planes. The characteristic findings provide high diagnostic accuracy, and axial plane is helpful to detect medial meniscal root tear. Diagnostic study, Level III.

  2. Surgical and nonsurgical management of sagittal slab fractures of the third carpal bone in racehorses: 32 cases (1991-2001).

    Science.gov (United States)

    Kraus, Beth M; Ross, Michael W; Boston, Raymond C

    2005-03-15

    To compare results (ie, return to racing and earnings per race start) of surgical versus nonsurgical management of sagittal slab fractures of the third carpal bone in racehorses. Retrospective study. 32 racehorses (19 Thoroughbreds, 11 Standardbreds, and 2 Arabians). Medical records and radiographs were reviewed to obtain information regarding signalment and treatment. Follow-up information was obtained from race records. Robust regression analysis was performed to evaluate earnings per start in horses that raced at least once before and after injury. 22 (69%) horses raced at least once after treatment of the fracture. All 7 horses treated by means of interfragmentary compression raced after treatment, and horses that underwent interfragmentary compression had significantly higher earnings per start after the injury than did horses treated without surgery. Eight of 9 horses treated by means of arthroscopic debridement of the damaged cartilage and bone raced after treatment, but only 7 of 16 horses treated without surgery (ie, stall rest) were able to return to racing after treatment. Results suggest that racehorses with sagittal slab fractures of the third carpal bone have a favorable prognosis for return to racing after treatment. Horses treated surgically were more likely to race after treatment than were horses treated without surgery.

  3. Ultrasound follow-up of posttraumatic injuries of the sagittal band of the dorsal hood treated by a conservative approach

    Energy Technology Data Exchange (ETDEWEB)

    Willekens, Inneke, E-mail: Inneke.willekens@gmail.com [Department of Radiology, Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Kichouh, Mimoun; Boulet, Cedric; De Maeseneer, Michel [Department of Radiology, Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Clarys, Jan Pieter [Department of Experimental Anatomy, Vrije Universiteit Brussel (VUB), Laarbeeklaan 103, 1090 Brussels (Belgium); Mey, Johan de [Department of Radiology, Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium)

    2015-02-15

    Highlights: • Dorsal Hood. • Extensor Hood. • Ultrasound. • Rupture. - Abstract: Traumatic dislocation of the extensor tendon over the metacarpophalangeal (MCP) joint is a rare problem in patients without rheumatoid disorders. The common extensor tendon is stabilized on the metacarpal head by components of the dorsal hood (DH). A tear in the sagittal bands, allows (sub)luxation of the tendon. To ensure appropriate treatment, the identification of the damaged structures is essential. Ultrasound (US) is a valuable method in the evaluation of DH injuries and in the follow-up for evaluation of healing or lack of healing of the lesions. We report three cases with partial rupture of the sagittal band of the DH: two cases in the index finger and one case in the long finger, which caused pain and swelling and was diagnosed with US. The patients were treated conservatively and the pain resolved after 9 months in case 1, 3 months in case 2 and 6 months in case 3. The follow-up at one year revealed painless full range of motion and no residual subluxation during the dynamic ultrasound.

  4. CHARACTERISTICS OF BODY POSTURE IN THE SAGITTAL PLANE AND FITNESS OF FIRST-FORM PUPILS FROM RURAL AREAS

    Directory of Open Access Journals (Sweden)

    Hanna Żukowska

    2014-07-01

    Full Text Available Purpose: to find correlations between characteristics of body posture in the sagittal plane and fitness and endurance of first-form children from rural areas. Material: an analysis of more than 30 sources of scientific and educational literature. Results: the study involved 209 children, including 102 girls and 107 boys. They were children who lived in the country since they were born. To assess particular characteristics of body posture, the children were studied by means of the measuring equipment using the projection Moiré system. Motor skills were estimated using selected EUROFIT physical fitness tests (sitting forward bend, standing broad jump, handgrip, sit-and-reach, bent arm hang and 10 x 5 m shuttle run. The level of physical endurance was evaluated with the Harvard Step Test modified by Montoye. Conclusions: the conducted research reveals statistically significant correlations between the characteristics of body posture in the sagittal plane and selected EUROFIT physical fitness tests and physical endurance of the children involved in the study.

  5. Postural alignment in children with Duchenne muscular dystrophy and its relationship with balance

    Directory of Open Access Journals (Sweden)

    Cyntia R. J. A. Baptista

    2014-05-01

    Full Text Available Background: In Duchenne muscular dystrophy, functional deficits seem to arise from body misalignment, deconditioning, and obesity secondary to weakness and immobility. The question remains about the effects of postural deviations on the functional balance of these children. Objectives: To identify and quantify postural deviations in children with DMD in comparison to non-affected children (eutrophic and overweight/obese, exploring relationships between posture and function. Method: This case-control study evaluated 29 participants aged 6 to 11 years: 10 DMD (DG, 10 eutrophic (EG, and 9 overweight/obese (OG. Digital photogrammetry and SAPo program were used to measure postural alignment and the Pediatric Balance Scale (PBS was used to measure balance. The Kruskall-Wallis and Dunn post-hoc tests were used for inter-group comparison of posture and balance. Spearman's coefficient tested the correlation between postural and balance variables. Results: The horizontal pelvic alignment data indicated that the anteversion of the DG was similar to that of the OG and twice that of the EG (p<0.05. Compared to the EG, the DG and OG showed an increased forward position of the center of mass (p<0.05. There was a moderate and weak correlation between the PBS score and horizontal pelvic alignment (0.58 and 0.47-left/right. The PBS showed a weak correlation with asymmetries in the sagittal plane (-0.39. The PBS scores for the OG and EG suggest that obesity did not have a deleterious effect on balance. Conclusions: The balance deficit in children with DMD was accompanied by an increased forward position of the center of mass and significant pelvic anteversion that constitutes a compensatory strategy to guarantee similar performance to the children not affected by the disease.

  6. MEMS Integrated Submount Alignment for Optoelectronics

    Science.gov (United States)

    Shakespeare, W. Jeffrey; Pearson, Raymond A.; Grenestedt, Joachim L.; Hutapea, Parsaoran; Gupta, Vikas

    2005-02-01

    One of the most expensive and time-consuming production processes for single-mode fiber-optic components is the alignment of the photonic chip or waveguide to the fiber. The alignment equipment is capital intensive and usually requires trained technicians to achieve desired results. Current technology requires active alignment since tolerances are only ~0.2 μ m or less for a typical laser diode. This is accomplished using piezoelectric actuated stages and active optical feedback. Joining technologies such as soldering, epoxy bonding, or laser welding may contribute significant postbond shift, and final coupling efficiencies are often less than 80%. This paper presents a method of adaptive optical alignment to freeze in place directly on an optical submount using a microelectromechanical system (MEMS) shape memory alloy (SMA) actuation technology. Postbond shift is eliminated since the phase change is the alignment actuation. This technology is not limited to optical alignment but can be applied to a variety of MEMS actuations, including nano-actuation and nano-alignment for biomedical applications. Experimental proof-of-concept results are discussed, and a simple analytical model is proposed to predict the stress strain behavior of the optical submount. Optical coupling efficiencies and alignment times are compared with traditional processes. The feasibility of this technique in high-volume production is discussed.

  7. Ergodic Interference Alignment with Delayed Feedback

    OpenAIRE

    Kang, Myung Gil; Choi, Wan

    2013-01-01

    We propose new ergodic interference alignment techniques for $K$-user interference channels with delayed feedback. Two delayed feedback scenarios are considered -- delayed channel information at transmitter (CIT) and delayed output feedback. It is proved that the proposed techniques achieve total $2K/(K+2)$ DoF which is higher than that by the retrospective interference alignment for the delayed feedback scenarios.

  8. Alignment issues in photonic crystal device fabrication

    NARCIS (Netherlands)

    de Ridder, R.M.; Bostan, C.G.; van Soest, Frank J.; Gadgil, V.J.

    2004-01-01

    An important requirement in the fabrication of photonic crystal structures is the correct relative alignment of structural elements. Accuracy should be in the order of some tens of nanometres. Some of the options for providing such accuracy are discussed. Examples are given of aligning defects with

  9. Compositions for directed alignment of conjugated polymers

    Science.gov (United States)

    Kim, Jinsang; Kim, Bong-Gi; Jeong, Eun Jeong

    2016-04-19

    Conjugated polymers (CPs) achieve directed alignment along an applied flow field and a dichroic ratio of as high as 16.67 in emission from well-aligned thin films and fully realized anisotropic optoelectronic properties of CPs in field-effect transistor (FET).

  10. Nanoscratch technique for aligning multiwalled carbon nanotubes ...

    Indian Academy of Sciences (India)

    horizontally aligned high-quality MWCNTs using the arc discharge method with the help of a metal scraper in an open air. This technique is extended after removing the soot from the cathode; physical forces are applied manu- ally on the surface of the soot to align the MWCNTs along the direction of the application of the ...

  11. Nanoscratch technique for aligning multiwalled carbon nanotubes ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 38; Issue 4. Nanoscratch technique for aligning multiwalled carbon nanotubes synthesized by the arc discharge method in open air. A Joseph ... The method demonstrated represents an economical approach for large-scale synthesis of aligned MWCNTs at low costs.

  12. STELLAR: fast and exact local alignments

    Directory of Open Access Journals (Sweden)

    Weese David

    2011-10-01

    Full Text Available Abstract Background Large-scale comparison of genomic sequences requires reliable tools for the search of local alignments. Practical local aligners are in general fast, but heuristic, and hence sometimes miss significant matches. Results We present here the local pairwise aligner STELLAR that has full sensitivity for ε-alignments, i.e. guarantees to report all local alignments of a given minimal length and maximal error rate. The aligner is composed of two steps, filtering and verification. We apply the SWIFT algorithm for lossless filtering, and have developed a new verification strategy that we prove to be exact. Our results on simulated and real genomic data confirm and quantify the conjecture that heuristic tools like BLAST or BLAT miss a large percentage of significant local alignments. Conclusions STELLAR is very practical and fast on very long sequences which makes it a suitable new tool for finding local alignments between genomic sequences under the edit distance model. Binaries are freely available for Linux, Windows, and Mac OS X at http://www.seqan.de/projects/stellar. The source code is freely distributed with the SeqAn C++ library version 1.3 and later at http://www.seqan.de.

  13. Plasmon Modes of Vertically Aligned Superlattices

    DEFF Research Database (Denmark)

    Filonenko, Konstantin; Duggen, Lars; Willatzen, Morten

    2017-01-01

    By using the Finite Element Method we visualize the modes of vertically aligned superlattice composed of gold and dielectric nanocylinders and investigate the emitter-plasmon interaction in approximation of weak coupling. We find that truncated vertically aligned superlattice can function as plas...

  14. Aligning Application Architecture to the Business Context

    NARCIS (Netherlands)

    Wieringa, Roelf J.; Blanken, Henk; Fokkinga, M.M.; Grefen, P.W.P.J.; Eder, J.; Missikoff, M.

    Alignment of application architecture to business architecture is a central problem in the design, acquisition and implementation of information systems in current large-scale information-processing organizations. Current research in architecture alignment is either too strategic or too software

  15. Automated interferometric alignment system for paraboloidal mirrors

    Science.gov (United States)

    Maxey, L. Curtis

    1993-01-01

    A method is described for a systematic method of interpreting interference fringes obtained by using a corner cube retroreflector as an alignment aid when aigning a paraboloid to a spherical wavefront. This is applicable to any general case where such alignment is required, but is specifically applicable in the case of aligning an autocollimating test using a diverging beam wavefront. In addition, the method provides information which can be systematically interpreted such that independent information about pitch, yaw and focus errors can be obtained. Thus, the system lends itself readily to automation. Finally, although the method is developed specifically for paraboloids, it can be seen to be applicable to a variety of other aspheric optics when applied in combination with a wavefront corrector that produces a wavefront which, when reflected from the correctly aligned aspheric surface will produce a collimated wavefront like that obtained from the paraboloid when it is correctly aligned to a spherical wavefront.

  16. Aligning Greek-English parallel texts

    Science.gov (United States)

    Galiotou, Eleni; Koronakis, George; Lazari, Vassiliki

    2015-02-01

    In this paper, we discuss issues concerning the alignment of parallel texts written in languages with different alphabets based on an experiment of aligning texts from the proceedings of the European Parliament in Greek and English. First, we describe our implementation of the k-vec algorithm and its application to the bilingual corpus. Then the output of the algorithm is used as a starting point for an alignment procedure at a sentence level which also takes into account mark-ups of meta-information. The results of the implementation are compared to those of the application of the Church and Gale alignment algorithm on the Europarl corpus. The conclusions of this comparison can give useful insights as for the efficiency of alignment algorithms when applied to the particular bilingual corpus.

  17. MICA: Multiple interval-based curve alignment

    Science.gov (United States)

    Mann, Martin; Kahle, Hans-Peter; Beck, Matthias; Bender, Bela Johannes; Spiecker, Heinrich; Backofen, Rolf

    2018-01-01

    MICA enables the automatic synchronization of discrete data curves. To this end, characteristic points of the curves' shapes are identified. These landmarks are used within a heuristic curve registration approach to align profile pairs by mapping similar characteristics onto each other. In combination with a progressive alignment scheme, this enables the computation of multiple curve alignments. Multiple curve alignments are needed to derive meaningful representative consensus data of measured time or data series. MICA was already successfully applied to generate representative profiles of tree growth data based on intra-annual wood density profiles or cell formation data. The MICA package provides a command-line and graphical user interface. The R interface enables the direct embedding of multiple curve alignment computation into larger analyses pipelines. Source code, binaries and documentation are freely available at https://github.com/BackofenLab/MICA

  18. Semiautomatic beam-based LHC collimator alignment

    Directory of Open Access Journals (Sweden)

    Gianluca Valentino

    2012-05-01

    Full Text Available Full beam-based alignment of the LHC collimation system was a time-consuming procedure (up to 28 hours as the collimators were set up manually. A yearly alignment campaign has been sufficient for now, although in the future due to tighter tolerances this may lead to a decrease in the cleaning efficiency if machine parameters such as the beam orbit drift over time. Automating the collimator setup procedure can reduce the beam time for collimator setup and allow for more frequent alignments, therefore reducing the risk of performance degradation. This article describes the design and testing of a semiautomatic algorithm as a first step towards a fully automatic setup procedure. The parameters used to measure the accuracy and performance of the alignment are defined and determined from experimental data. A comparison of these measured parameters at 450 GeV and 3.5 TeV with manual and semiautomatic alignment is provided.

  19. Semiautomatic beam-based LHC collimator alignment

    Science.gov (United States)

    Valentino, Gianluca; Aßmann, Ralph; Bruce, Roderik; Redaelli, Stefano; Rossi, Adriana; Sammut, Nicholas; Wollmann, Daniel

    2012-05-01

    Full beam-based alignment of the LHC collimation system was a time-consuming procedure (up to 28 hours) as the collimators were set up manually. A yearly alignment campaign has been sufficient for now, although in the future due to tighter tolerances this may lead to a decrease in the cleaning efficiency if machine parameters such as the beam orbit drift over time. Automating the collimator setup procedure can reduce the beam time for collimator setup and allow for more frequent alignments, therefore reducing the risk of performance degradation. This article describes the design and testing of a semiautomatic algorithm as a first step towards a fully automatic setup procedure. The parameters used to measure the accuracy and performance of the alignment are defined and determined from experimental data. A comparison of these measured parameters at 450 GeV and 3.5 TeV with manual and semiautomatic alignment is provided.

  20. Ultrasonic inspections of fuel alignment pins

    International Nuclear Information System (INIS)

    Rathgeb, W.; Schmid, R.

    1994-01-01

    As a remedy to the practical problem of defects in fuel alignment pins made of Inconel X750, an inspection technique has been developed which fully meets the requirements of detecting defects. The newly used fuel alignment pins made of austenite are easy to test and therefore satisfy the necessity of further inspections.For the fuel alignment pins of the upper core structure a safe and fast inspection technique was made available. The inspection sensitivity is high and it is possible to give quantitative directions concerning defect orientation and depth. After the required inspections had been concluded in 1989, a total of 18 inspections were carried out in various national and international nuclear power plants in the following years. During this time more than 6000 fuel alignment pines were examined.For the fuel alignment pins the inspection technique provided could increase the understanding of the defect process. This technique contributed to the development of an adaptive and economical repair strategy. ((orig.))

  1. Semiautomatic beam-based LHC collimator alignment

    CERN Document Server

    Valentino, Gianluca; Bruce, Roderik; Wollmann, Daniel; Sammut, Nicholas; Rossi, Adriana; Redaelli, Stefano

    2012-01-01

    Full beam-based alignment of the LHC collimation system was a time-consuming procedure (up to 28 hours) as the collimators were set up manually. A yearly alignment campaign has been sufficient for now, although in the future due to tighter tolerances this may lead to a decrease in the cleaning efficiency if machine parameters such as the beam orbit drift over time. Automating the collimator setup procedure can reduce the beam time for collimator setup and allow for more frequent alignments, therefore reducing the risk of performance degradation. This article describes the design and testing of a semiautomatic algorithm as a first step towards a fully automatic setup procedure. The parameters used to measure the accuracy and performance of the alignment are defined and determined from experimental data. A comparison of these measured parameters at 450 GeV and 3.5 TeV with manual and semiautomatic alignment is provided.

  2. RevTrans: multiple alignment of coding DNA from aligned amino acid sequences

    DEFF Research Database (Denmark)

    Wernersson, Rasmus; Pedersen, Anders Gorm

    2003-01-01

    The simple fact that proteins are built from 20 amino acids while DNA only contains four different bases, means that the 'signal-to-noise ratio' in protein sequence alignments is much better than in alignments of DNA. Besides this information-theoretical advantage, protein alignments also benefit...... analysis. RevTrans also accepts user-provided protein alignments for greater control of the alignment process. The RevTrans web server is freely available at http://www.cbs.dtu.dk/services/RevTrans/....

  3. Tracing magnetic fields with aligned grains

    International Nuclear Information System (INIS)

    Lazarian, A.

    2007-01-01

    Magnetic fields play a crucial role in various astrophysical processes, including star formation, accretion of matter, transport processes (e.g., transport of heat), and cosmic rays. One of the easiest ways to determine the magnetic field direction is via polarization of radiation resulting from extinction or/and emission by aligned dust grains. Reliability of interpretation of the polarization maps in terms of magnetic fields depends on how well we understand the grain-alignment theory. Explaining what makes grains aligned has been one of the big issues of the modern astronomy. Numerous exciting physical effects have been discovered in the course of research undertaken in this field. As both the theory and observations matured, it became clear that the grain-alignment phenomenon is inherent not only in diffuse interstellar medium or molecular clouds but also is a generic property of the dust in circumstellar regions, interplanetary space and cometary comae. Currently the grain-alignment theory is a predictive one, and its results nicely match observations. Among its predictions is a subtle phenomenon of radiative torques. This phenomenon, after having stayed in oblivion for many years after its discovery, is currently viewed as the most powerful means of alignment. In this article, I shall review the basic physical processes involved in grain alignment, and the currently known mechanisms of alignment. I shall also discuss possible niches for different alignment mechanisms. I shall dwell on the importance of the concept of grain helicity for understanding of many properties of grain alignment, and shall demonstrate that rather arbitrarily shaped grains exhibit helicity when they interact with gaseous and radiative flows

  4. The paravertebral muscle and psoas for the maintenance of global spinal alignment in patient with degenerative lumbar scoliosis.

    Science.gov (United States)

    Yagi, Mitsuru; Hosogane, Naobumi; Watanabe, Kota; Asazuma, Takashi; Matsumoto, Morio

    2016-04-01

    Various factors are reported to affect the spinal alignment in degenerative lumbar scoliosis (DLS). Although trunk muscles also appear to affect spinal alignment, the role of the trunk muscles is not yet clear. The aim was to elucidate the role of the multifidus (MF) and psoas (PS) in maintaining global spinal alignment in patients with DLS. This was a multicenter retrospective matched cohort study. Surgically treated 60 paired DLS and lumbar spinal stenosis (LSS) female (120 patients), matched for age and body mass index (BMI; DLS age 68.0±6.8 vs. LSS 67.1±8.9 years; BMI 21.6±3.3 vs. 23.2±3.8 kg/m(2)), were included and were followed for at least 2 years. Spinal alignment, muscle area, and volume were measured from radiographs, magnetic resonance images (MRIs), and whole-body dual-energy X-ray absorptiometry (DXA) scans. Muscle strength was measured by grip power and peak expiratory flow (PEF). As a surrogate of muscle area, we obtained the cross-sectional area (CSA) at the L5-S level from preoperative MRIs. The MF and PS CSAs were significantly smaller in the DLS group than in the LSS group (MF 477.7±192.5 vs. 779.8±248.6 mm(2), pstrength or PEF tests between the groups. Correlation coefficient tests showed moderate correlations between the MF average CSA (avCSA) and global spinal alignment and spinopelvic alignment (pelvic incidence-lumbar lordosis; R=-0.37, -0.38) in the DLS group. The MF avCSA was correlated with the postoperative progression of kyphosis at the unfused thoracic vertebrae in the DLS group (R=0.34). The CSAs of the MF and PS were significantly smaller in the DLS group. Whole-body DXA showed no significant difference in the lean composition between the groups. There were significant correlations in the DLS patients between the MF CSA and sagittal spinal alignment. These findings suggest the causal relationship between muscles and global spine alignment. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Sagittal and vertical aspects of Class II division 1 subjects according to the respiratory pattern.

    Science.gov (United States)

    Cabrera, Laura de Castro; Retamoso, Luciana Borges; Mei, Raul Magnoler Sampaio; Tanaka, Orlando

    2013-01-01

    The teeth position, specially maxillary and mandibular incisors, in relation to basal bone and surrounding soft tissues must be considered in the elaboration of diagnosis, treatment planning and execution to obtain alignment, leveling, intercuspation, facial balance and harmony with stability of results. To evaluate the modifications in the positioning of incisors in individuals with Angle Class II, division 1 malocclusion in two distinct moments of dentocraniofacial development, with mean interval of 2 years and 5 months. The measures were obtained by means of lateral cephalograms of 40 individuals, being 23 nasal breathers (NB) and 17 mouth breathers (MB). The analyzed measures were overjet, overbite, UCI-NA, LCI-NB, UCI.NA, LCI.NB, UCI.SN, LCI.GoGn, UCI.LCI, ANB, GoGn.SN, and OccPl.SN. Statistical analysis (2-way repeated-measures ANOVA) was applied to verify intergroups differences. Overjet, UCI-NA, LCI-NB, ANB, GoGn.SN, and OccPl.SN demonstrated statistically significant difference (p < 0.05) when observed the moment or the respiratory method. There is alteration in the positioning of incisors during growth with interference of the respiratory pattern.

  6. Sagittal and vertical aspects of Class II division 1 subjects according to the respiratory pattern

    Directory of Open Access Journals (Sweden)

    Laura de Castro Cabrera

    2013-04-01

    Full Text Available INTRODUCTION: The teeth position, specially maxillary and mandibular incisors, in relation to basal bone and surrounding soft tissues must be considered in the elaboration of diagnosis, treatment planning and execution to obtain alignment, leveling, intercuspation, facial balance and harmony with stability of results. OBJECTIVES: To evaluate the modifications in the positioning of incisors in individuals with Angle Class II, division 1 malocclusion in two distinct moments of dentocraniofacial development, with mean interval of 2 years and 5 months. METHODS: The measures were obtained by means of lateral cephalograms of 40 individuals, being 23 nasal breathers (NB and 17 mouth breathers (MB. The analyzed measures were overjet, overbite, UCI-NA, LCI-NB, UCI.NA, LCI.NB, UCI.SN, LCI.GoGn, UCI.LCI, ANB, GoGn.SN, and OccPl.SN. Statistical analysis (2-way repeated-measures ANOVA was applied to verify intergroups differences. RESULTS: Overjet, UCI-NA, LCI-NB, ANB, GoGn.SN, and OccPl.SN demonstrated statistically significant difference (p < 0.05 when observed the moment or the respiratory method. CONCLUSION: There is alteration in the positioning of incisors during growth with interference of the respiratory pattern.

  7. Clear aligners for orthodontic treatment?

    Science.gov (United States)

    Javidi, Hanieh; Graham, Elizabeth

    2015-12-01

    PubMed/Medline, Embase, Cochrane Central Register of Controlled Clinical trials (CENTRAL), Web of Knowledge, SCOPUS, Google Scholar and LILACS databases. Clinical prospective and retrospective studies of orthodontic treatment with clear aligners on patients over the age of 15 that included clear descriptions of the materials and applied technique were included. Selection was undertaken independently by two reviewers. Two reviewers extracted data independently with study quality being assessed using the grading system described by the Swedish Council on Technology Assessment in Health Care (SBU). A narrative summary of the findings was presented. Eleven studies involving a total of 480 patients were included consisting of two randomised controlled trials, five prospective studies and four retrospective studies. Six studies were considered to be of moderate quality, the remainder of limited quality. Most of the studies presented with methodological problems: small sample size, bias and confounding variables, lack of method error analysis, blinding in measurements, and deficient or missing statistical methods. The quality level of the studies was not sufficient to draw any evidence-based conclusions.

  8. Effect of Acute Alterations in Foot Strike Patterns during Running on Sagittal Plane Lower Limb Kinematics and Kinetics

    Directory of Open Access Journals (Sweden)

    Kevin A. Valenzuela, Scott K. Lynn, Lisa R. Mikelson, Guillermo J. Noffal, Daniel A. Judelson

    2015-03-01

    Full Text Available subjects were identified through slow motion video playback (n = 21, age = 22.8±2.2 years, mass = 73.1±14.5 kg, height 1.75 ± 0.10 m. On day two, subjects performed five overground run trials in both their natural and unnatural strike patterns while motion and force data were collected. Data were collected over two days so that foot strike videos could be analyzed for group placement purposes. Several 2 (Foot Strike Pattern –forefoot strike [FFS], rearfoot strike [RFS] x 2 (Group – PFFG, PRFG mixed model ANOVAs (p < 0.05 were run on speed, active peak vertical ground reaction force (VGRF, peak early stance and mid stance sagittal ankle moments, sagittal plane hip and knee moments, ankle dorsiflexion ROM, and sagittal plane hip and knee ROM. There were no significant interactions or between group differences for any of the measured variables. Within subject effects demonstrated that the RFS condition had significantly lower (VGRF (RFS = 2.58 ± .21 BW, FFS = 2.71 ± 0.23 BW, dorsiflexion moment (RFS = -2.6 1± 0.61 Nm·kg-1, FFS = -3.09 ± 0.32 Nm·kg-1, and dorsiflexion range of motion (RFS = 17.63 ± 3.76°, FFS = 22.10 ± 5.08°. There was also a significantly higher peak plantarflexion moment (RFS = 0.23 ± 0.11 Nm·kg-1, FFS = 0.01 ± 0.01 Nm·kg-1, peak knee moment (RFS = 2.61 ± 0.54 Nm·kg-1, FFS = 2.39 ± 0.61 Nm·kg-1, knee ROM (RFS = 31.72 ± 2.79°, FFS = 29.58 ± 2.97°, and hip ROM (RFS = 42.72 ± 4.03°, FFS = 41.38 ± 3.32° as compared with the FFS condition. This research suggests that acute changes in foot strike patterns during shod running can create alterations in certain lower limb kinematic and kinetic measures that are not dependent on the preferred foot strike pattern of the individual. This research also challenges the contention that the impact transient spike in the vertical ground reaction force curve is only present during a rear foot strike type of running gait.

  9. Posterior epidural fat on sagittal MR images: can it heIp in distinguishing between isthmic and degenerative lumbar spondylolisthesis?

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Byung Jae; Choi, Jung Ah; Kim, Jung Eun; Choi, Ja Young; Hong, Sung Hwan; Kang, Heung Sik [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2004-11-01

    We tried to assess the value of posterior epidural fat for distinguishing isthmic spondylolisthesis from degenerative lumbar spondylolisthesis on midline sagittal MR images. The midline sagittal MR images of the lumbar spines were retrospectively studied for 50 patients without spondylolisthesis, for 78 patients with isthmic spondylolisthesis and for 43 patients with degenerative spondylolisthesis. The anteroposterior diameter of the posterior epidural fat (ADEF) was measured at each intervertebral disc level by two radiologists and these values were then compared between each group. To normalize for difference of body size, the posterior epidural fat ratio (PEFR) at each level of spondylolisthesis and at L1-2 were also determined for each level of spondylolisthesis, and the PERF was compared between each group. Statistical analysis was performed by the chi-square method. For the patients with isthmic spondylolisthesis, the ADEFs at the spinal levels with spondylolisthesis were significantly greater than those ADEFs in the control group that were measured at the corresponding disc levels (p<0.05). For the patients with degenerative spondylolisthesis, the ADEFs at the spinal level with spondylolisthesis were significantly less than the ADEFs in the control group that were measured at the corresponding disc levels (p<0.05). The PEFRs obtained at L4-5 were 1.37{+-}0.12 for the control group, 2.61{+-}1.31 for the patients with isthmic spondylolisthesis, and 0.60{+-}0.05 for the patients with degenerative spondylolisthesis. The PEFRs obtained at L5-S1 were 2.25{+-}1.32 for the control group, 3.47{+-}1.69 for the patients with isthmic spondylolisthesis and 1.65{+-}0.18 for the patients with degenerative spondylolisthesis. At both levels, the PEFRs were greatest for the isthmic spondylolisthesis group and smallest for the degenerative spondylolisthesis group, and all the differences were statistically significant. The posterior epidural fat, which is easily seen structure

  10. Sparse alignment for robust tensor learning.

    Science.gov (United States)

    Lai, Zhihui; Wong, Wai Keung; Xu, Yong; Zhao, Cairong; Sun, Mingming

    2014-10-01

    Multilinear/tensor extensions of manifold learning based algorithms have been widely used in computer vision and pattern recognition. This paper first provides a systematic analysis of the multilinear extensions for the most popular methods by using alignment techniques, thereby obtaining a general tensor alignment framework. From this framework, it is easy to show that the manifold learning based tensor learning methods are intrinsically different from the alignment techniques. Based on the alignment framework, a robust tensor learning method called sparse tensor alignment (STA) is then proposed for unsupervised tensor feature extraction. Different from the existing tensor learning methods, L1- and L2-norms are introduced to enhance the robustness in the alignment step of the STA. The advantage of the proposed technique is that the difficulty in selecting the size of the local neighborhood can be avoided in the manifold learning based tensor feature extraction algorithms. Although STA is an unsupervised learning method, the sparsity encodes the discriminative information in the alignment step and provides the robustness of STA. Extensive experiments on the well-known image databases as well as action and hand gesture databases by encoding object images as tensors demonstrate that the proposed STA algorithm gives the most competitive performance when compared with the tensor-based unsupervised learning methods.

  11. Multiple structure alignment with msTALI.

    Science.gov (United States)

    Shealy, Paul; Valafar, Homayoun

    2012-05-20

    Multiple structure alignments have received increasing attention in recent years as an alternative to multiple sequence alignments. Although multiple structure alignment algorithms can potentially be applied to a number of problems, they have primarily been used for protein core identification. A method that is capable of solving a variety of problems using structure comparison is still absent. Here we introduce a program msTALI for aligning multiple protein structures. Our algorithm uses several informative features to guide its alignments: torsion angles, backbone Cα atom positions, secondary structure, residue type, surface accessibility, and properties of nearby atoms. The algorithm allows the user to weight the types of information used to generate the alignment, which expands its utility to a wide variety of problems. msTALI exhibits competitive results on 824 families from the Homstrad and SABmark databases when compared to Matt and Mustang. We also demonstrate success at building a database of protein cores using 341 randomly selected CATH domains and highlight the contribution of msTALI compared to the CATH classifications. Finally, we present an example applying msTALI to the problem of detecting hinges in a protein undergoing rigid-body motion. msTALI is an effective algorithm for multiple structure alignment. In addition to its performance on standard comparison databases, it utilizes clear, informative features, allowing further customization for domain-specific applications. The C++ source code for msTALI is available for Linux on the web at http://ifestos.cse.sc.edu/mstali.

  12. Comparison of effective Hough transform-based fingerprint alignment approaches

    CSIR Research Space (South Africa)

    Mlambo, CS

    2014-08-01

    Full Text Available In this paper, two effective and mostly used Hough Transform (HT) based fingerprint alignment approaches are compared, namely; Local Match Based Alignment (LMBA) and Discretized Rotation Based Alignment (DRBA). The comparison was performed...

  13. Automatic Angular alignment of LHC Collimators

    CERN Document Server

    Azzopardi, Gabriella; Salvachua Ferrando, Belen Maria; Mereghetti, Alessio; Bruce, Roderik; Redaelli, Stefano; CERN. Geneva. ATS Department

    2017-01-01

    The LHC is equipped with a complex collimation system to protect sensitive equipment from unavoidable beam losses. Collimators are positioned close to the beam using an alignment procedure. Until now they have always been aligned assuming no tilt between the collimator and the beam, however, tank misalignments or beam envelope angles at large-divergence locations could introduce a tilt limiting the collimation performance. Three different algorithms were implemented to automatically align a chosen collimator at various angles. The implementation was tested on a number of collimators during this MD and no human intervention was required.