  1. Percutaneous transradial artery approach for coronary stent implantation.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J

    1993-10-01

    A new approach for implantation of Palmaz Schatz coronary stents is reported. We describe the technique and rationale of coronary stenting with miniaturized angioplasty equipment via the radial artery. This technique is illustrated in three patients. One patient underwent Palmaz Schatz stent implantation for a saphenous vene coronary bypass graft stenosis, the second patient for a restenosis in the anterior descending coronary artery after atherectomy, and the third patient for a second restenosis after balloon angioplasty in the circumflex coronary artery.

  2. Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design Considerations.

    Science.gov (United States)

    Beier, Susann; Ormiston, John; Webster, Mark; Cater, John; Norris, Stuart; Medrano-Gracia, Pau; Young, Alistair; Cowan, Brett

    2016-02-01

    Stent induced hemodynamic changes in the coronary arteries are associated with higher risk of adverse clinical outcome. The purpose of this study was to evaluate the impact of stent design on wall shear stress (WSS), time average WSS, and WSS gradient (WSSG), in idealized stent geometries using computational fluid dynamics. Strut spacing, thickness, luminal protrusion, and malapposition were systematically investigated and a comparison made between two commercially available stents (Omega and Biomatrix). Narrower strut spacing led to larger areas of adverse low WSS and high WSSG but these effects were mitigated when strut size was reduced, particularly for WSSG. Local hemodynamics worsened with luminal protrusion of the stent and with stent malapposition, adverse high WSS and WSSG were identified around peak flow and throughout the cardiac cycle respectively. For the Biomatrix stent, the adverse effect of thicker struts was mitigated by greater strut spacing, radial cell offset and flow-aligned struts. In conclusion, adverse hemodynamic effects of specific design features (such as strut size and narrow spacing) can be mitigated when combined with other hemodynamically beneficial design features but increased luminal protrusion can worsen the stent's hemodynamic profile significantly.

  3. Simulation of stent deployment in a realistic human coronary artery

    Directory of Open Access Journals (Sweden)

    van der Steen Anton FW

    2008-08-01

    Full Text Available Abstract Background The process of restenosis after a stenting procedure is related to local biomechanical environment. Arterial wall stresses caused by the interaction of the stent with the vascular wall and possibly stress induced stent strut fracture are two important parameters. The knowledge of these parameters after stent deployment in a patient derived 3D reconstruction of a diseased coronary artery might give insights in the understanding of the process of restenosis. Methods 3D reconstruction of a mildly stenosed coronary artery was carried out based on a combination of biplane angiography and intravascular ultrasound. Finite element method computations were performed to simulate the deployment of a stent inside the reconstructed coronary artery model at inflation pressure of 1.0 MPa. Strut thickness of the stent was varied to investigate stresses in the stent and the vessel wall. Results Deformed configurations, pressure-lumen area relationship and stress distribution in the arterial wall and stent struts were studied. The simulations show how the stent pushes the arterial wall towards the outside allowing the expansion of the occluded artery. Higher stresses in the arterial wall are present behind the stent struts and in regions where the arterial wall was thin. Values of 200 MPa for the peak stresses in the stent strut were detected near the connecting parts between the stent struts, and they were only just below the fatigue stress. Decreasing strut thickness might reduce arterial damage without increasing stresses in the struts significantly. Conclusion The method presented in this paper can be used to predict stresses in the stent struts and the vessel wall, and thus evaluate whether a specific stent design is optimal for a specific patient.

  4. Spontaneous coronary artery dissection: complete angiographic resolution without stenting

    Directory of Open Access Journals (Sweden)

    Alexandre Abizaid

    2007-09-01

    Full Text Available A case of spontaneous coronary artery dissection in a 49-year-oldwoman is presented. She did not present the classical cardiovascular riskfactors. Etiology and treatment are discussed. She underwent primarypercutaneous coronary intervention of the left anterior descendingartery with no stenting and had complete angiographic resolution.

  5. The conical stent in coronary artery improves hemodynamics compared with the traditional cylindrical stent.

    Science.gov (United States)

    Yu, Yi; Zhou, Yujie; Ma, Qian; Jia, Shuo; Wu, Sijing; Sun, Yan; Liu, Xiaoli; Zhao, Yingxin; Liu, Yuyang; Shi, Dongmei

    2017-01-15

    This study sought to explore the efficacy of the conical stent implantation in the coronary artery by comparing the effects of cylindrical and conical stents on wall shear stress (WSS) and velocity of flow and fractional flow reserve (FFR). The traditional cylindrical stent currently used in the percutaneous coronary intervention (PCI) has a consistent diameter, which does not match the physiological change of the coronary artery. On the contrary, as a new patent, the conical stent with tapering lumen is consistent with the physiological change of vascular diameter. However, the effect of the conical stent implantation on the coronary hemodynamics remains unclear. The coronary artery, artery stenosis and two stent models were established by Solidworks software. All models were imported into the computational fluid dynamics (CFD) software ANSYS ICEM-CFD to establish the fluid model. After the boundary conditions were set, CFD analysis was proceeded to compare the effects of two stent implantation on the change of WSS, velocity of flow and FFR. Hemodynamic indexes including FFR, blood flow velocity distribution (BVD) and WSS were improved by either the cylindrical or the conical stent implantation. However, after the conical stent implantation, the change of FFR seemed to be slower and more homogenous; the blood flow velocity was more appropriate without any obvious blood stagnation and direction changes; the WSS after the conical stent implantation was uniform from the proximal to distal side of the stent. Compared with the cylindrical stent, the conical stent implantation in the coronary artery can make the changes of vascular hemodynamic more closer to the physiological condition, which can reduce the incidence of intra-stent restenosis and thrombosis, thus making it more suitable for PCI therapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Repair of an Atherosclerotic Coronary Artery Aneurysm by Implantation of a Coronary Covered Stent

    Directory of Open Access Journals (Sweden)

    Antenor Portela

    2002-05-01

    Full Text Available An atherosclerotic aneurysm of the right coronary artery complicated by a recent myocardial infarction was successfully treated with coronary artery stenting, using a device consisting of 2 stents with a layer of expandable polytetrafluorethylene (PTFE placed between them. A follow-up angiograph 5 months after the procedure showed sustained initial results.

  7. Emergency coronary artery stenting for coronary dissection complicating diagnostic cardiac catheterisation.

    OpenAIRE

    Knight, C; Stables, R; Sigwart, U

    1995-01-01

    Dissection of a coronary artery is a recognised and significant complication of diagnostic coronary angiography that often requires emergency coronary artery bypass grafting. A coronary stent was used to treat this complication. This technique has potential advantages in terms of speed of reperfusion and availability in centres performing diagnostic angiography without surgical cover on site.

  8. INTRAVASCULAR ULTRASOUND EVALUATING CORONARY STENTS FOR PATIENTS WITH CORONARY ARTERY DISEASE: COMPARED OLD WITH NEW MULTILINK STENTS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Objective.It was suggested that coronary stent design and coating may affect stent performance and hence induce varying degrees of thrombogenesis and neointimal hyperplasia.The purpose of this study is to compare the 6 month follow up results between old and new Multilink stents with the method of intravascular ultrasound (IVUS) imaging.Methods.We have performed old (n=40) and new (n=35) Multilink stent implantations on 75 patients with coronary artery disease.Coronary angiography was performed before,immediately after,and 6 months after the in stent procedure respectively.Six month follow up IVUS imaging was performed and analyzed off line.Results.Minimal lumen cross sectional area (CSA) of new Multilink stents was significantly larger than that of old Multilink stents (P=0.0053).Mean stent lumen area of new Multilink stents was significantly larger than that of old Multilink stents (P=0.040).Similarly,minimal lumen diameter (MLD) of new Multilink stents was larger than that of old Multilink stents (P= 0.011).Old Multilink stents had a higher percentage of plaque area than new Multilink stents.Conclusion.The new Multilink stent is obviously superior to old Multilink stents,in particular,in the stent MLD and lumen CSA- - major determinants of the restenosis.

  9. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R. [Univ. of Muenster (Germany). Dept. of Clinical Radiology; Grude, M. [Univ. of Muenster (Germany). Dept. of Cardiology and Angiology

    2003-11-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 {+-} 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  10. Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schepis, Tiziano; Koepfli, Pascal; Gaemperli, Oliver; Eberli, Franz R.; Luescher, Thomas F. [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); Leschka, Sebastian; Desbiolles, Lotus; Husmann, Lars; Wildermuth, Simon; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); Zurich Center for Integrative Human Physiology, Zurich (Switzerland)

    2007-06-15

    We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 {+-} 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 {+-} 0.39 mm versus 2.49 {+-} 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 {+-} 6.2 mm, correlating well with CT (18.5 {+-} 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 {+-} 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA. (orig.)

  11. Successful treatment of coronary artery pseudoaneurysm by graft stent, which developed after the implantation of bare metal stent

    Directory of Open Access Journals (Sweden)

    Utku Şenol

    2013-03-01

    Full Text Available Although coronary artery pseudoaneurysm which couldoccur following percutaneous coronary interventions is arare complication, it can be mortal. As soon as the pseudoaneurysmis diagnosed, it should be treated by percutaneousintervention or surgery. Graft stent implantationis a preferred treatment for appropriate patients. In thiscase report, we presented a successful treatment of coronaryartery pseudoaneurysm by graft stent; which developedafter the implantation of bare metal stent into theleft anterior descending coronary artery. J Clin Exp Invest2013; 4 (1: 126-129Key words: Coronary artery, pseudoaneurysm, graft stent

  12. Minimally invasive direct coronary artery bypass plus coronary stent for acute coronary syndrome: a case report

    Institute of Scientific and Technical Information of China (English)

    Caiyi Lu; Gang Wang; Qi Zhou; Jinwen Tian; Lei Gao; Shenhua Zhou; Jinyue Zhai; Rui Chen; Zhongren Zhao; Cangqing Gao; Shiwen Wang; Yuxiao Zhang; Ming Yang; Qiao Xue; Cangsong Xiao; Wei Gao; Yang Wu

    2008-01-01

    A 69-year old female patient was admitted because of 3 days of worsened chest pain.Coronary angiography showed60% stenosis of distal left main stem,chronic total occlusion of left anterior descending (LAD),70% stenosis at the ostium of a smallleft circumflex,70-90%stenosis at the paroxysmal and middle part of a dominant fight coronary artery (RCA),and a normal left internalmammary artery (LIMA) with normal origination and orientation.Percutaneous intervention was attempted but failed on the occludedlesion of LAD.The patient received minimally invasive direct coronary artery bypass (MIDCAB) with left LIMA isolation by Davincirobot.Eleven days later,the RCA lesion was treated by Sirolimus Rapamicin eluting stents implantation percutaneously.Then thepatient was discharged uneventfully after 3 days hospitalization.Our experience suggests that two stop shops of hybrid technique befeasible and safe in the treatment of elderly patient with multiple coronary diseases.

  13. [Exrercise tolerance in patients with coronary artery disease after coronary artery stenting].

    Science.gov (United States)

    Tseluyko, V; Kreyndel, K; Vashakidze, Z

    2014-01-01

    The aim of the research is to investigate the impact of coronary stenting on exercise tolerance after 4-8 week and after 12-15 months. The study involved total 90 patients with coronary artery disease, who underwent coronary stenting. All patients underwent clinical examination, including an assessment of their condition, the frequency of angina attacks, echocardioscopy, resting ECG was recorded in all the patients in the standard 12 -lead veloergometry. Statistical processing was performed using Statistica 6.0 for Windows, the method of Wald - Wolfowitz . Data are presented as arithmetic means and error average M ± m. We used a statistical method of calculation - the median ranks (with the median calculated by the usual rules of statistics - the arithmetic mean of the central members of the ordered series). Significant differences were assessed by t-test . The level of significance was considered significant when p <0,05. According to the monitoring data of patients have a significant increase in exercise tolerance: threshold power increased by 63% and in 12-15 months by 58 % compared with the original. The duration of the test conducted after stenting increased by almost 2 -fold. In addition, significantly reduced the proportion of patients whose test results were evaluated as positive. Stenting of the coronary arteries after 4-8 weeks promotes the significant increase in exercise tolerance that persists after 12-15 months. The factors of associated with insufficient increase in exercise tolerance after stenting according veloergometry are: female gender, diabetes, smoking cessation further contributes to the increase in the threshold of physical activity.

  14. Mechanical compression of coronary artery stents: potential hazard for patients undergoing cardiopulmonary resuscitation.

    Science.gov (United States)

    Windecker, S; Maier, W; Eberli, F R; Meier, B; Hess, O M

    2000-12-01

    Mechanical compression of coronary artery stents may be associated with a fatal outcome as the result of refractory myocardial ischemia. We present the history of an 83-yr-old patient, who died owing to hemorrhagic shock 3 days after stent implantation, despite immediate cardiopulmonary resuscitation (CPR). Postmortem examination showed stent compression, probably due to mechanical deformation during CPR. This complication has been reported in two other cases in the literature, suggesting that CPR may be hazardous to patients with coronary artery stents.

  15. Sirolimus-eluting stent fractures associated with aneurysm and very late stent thrombosis in the right coronary artery

    Institute of Scientific and Technical Information of China (English)

    LIU Xuebo; Gary S.Mintz; Stéphane G.Carlier; Martin B.Leon

    2007-01-01

      Although the occurrence of coronary stent fracture is rare,recent reports showed that stent fracture after sirolimus-eluting stent(SES)implantation may be associated with neointimal hyperplasia and restenosis.We report two cases of stent fracture that occurred late after elective SES implantation into the right coronary artery(RCA)that were related to the aneurysm,restenosis,thrombosis,and vessel occlusion.……

  16. Off-pump coronary artery bypass grafting or percutaneous transluminal coronary angioplasty with stenting for proximal left anterior descending coronary artery disease?

    NARCIS (Netherlands)

    Drenth, Derk Jan

    2005-01-01

    This thesis describes and discusses the results of a prospective randomized controlled clinical trial comparing percutaneous coronary angioplasty with stenting (stenting) and off-pump coronary artery bypass grafting with a left internal mammary artery (surgery) in patients with a high-grade stenosis

  17. Off-pump coronary artery bypass grafting or percutaneous transluminal coronary angioplasty with stenting for proximal left anterior descending coronary artery disease?

    NARCIS (Netherlands)

    Drenth, Derk Jan

    2005-01-01

    This thesis describes and discusses the results of a prospective randomized controlled clinical trial comparing percutaneous coronary angioplasty with stenting (stenting) and off-pump coronary artery bypass grafting with a left internal mammary artery (surgery) in patients with a high-grade stenosis

  18. Application of 64 slice spiral CT in evaluating the patency of coronary artery after stent implantation

    Institute of Scientific and Technical Information of China (English)

    Yong-Shu Gao; Xing-Can Ma

    2015-01-01

    Objective:To explore the feasibility and effectiveness of 64 slice spiral CT in evaluating the patency of coronary artery after stent implantation.Methods:The 64 slice spiral CT image data of 125 patients after coronary artery stent implantation were collected, meanwhile, the image data of 25 patients underwent coronary angiography were also collected. The feasibility and accuracy of 64 slice spiral CT coronary artery stent imaging were comparatively analyzed. Results: The 64 slice spiral CT imaging quality with a stent diameter greater than 3.00 mm was significantly superior to that with a diameter of 2.25-3.00 mm. The CT imaging quality in the left main coronary artery and anterior descending artery was significantly higher than that in the left circumflex coronary artery. The CT imaging quality in the left main coronary artery was significantly higher than that in the right coronary artery. The CT reconstruction imaging quality in the drug coating stent was significantly superior to that in the bare metal stent. The sensitivity of 64 slice spiral CT was 100.00%, and the accuracy was 100.00%. In detecting the coronary artery with occlusion and stenosis (stent stenosis greater than 50%), the sensitivity was 90.00%, the false negative rate was 10.00%, and the positive predicative value was 100.00%.Conclusions:The effect of 64 slice spiral CT coronary imaging in evaluating the patency of coronary artery after stent implantation is highly consistent with that by coronary angiography, with a simple operation, less risk, and low cost, and thus, it can be completely taken as the imaging method in evaluating the patency of coronary artery after stent implantation.

  19. Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Maintz, David; Juergens, Kai-Uwe; Heindel, Walter; Fischbach, Roman [Department of Clinical Radiology, University of Muenster, Albert-Schweitzer-Strasse 33, 48129 Muenster (Germany); Wichter, Thomas; Grude, Matthias [Department of Cardiology and Angiology, University of Muenster, Albert-Schweitzer-Strasse 33 48129 Muenster (Germany)

    2003-04-01

    The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent lumen was totally obscured in the Wiktor stent, the Wallgraft stent, and the Nir Royal stent. Partial residual of the stent lumen could be visualized in all other utilized stent products (artificial lumen reductions ranged from 62% in the V-Flex stent to 94% in the Bx Velocity stent). Parts of the stent lumen can be visualized in most coronary artery stents; however, detectability of in-stent stenoses remains to be evaluated for each stent type. (orig.)

  20. Stent-induced coronary artery stenosis characterized by multimodal nonlinear optical microscopy

    Science.gov (United States)

    Wang, Han-Wei; Simianu, Vlad; Locker, Mattew J.; Cheng, Ji-Xin; Sturek, Michael

    2011-02-01

    We demonstrate for the first time the applicability of multimodal nonlinear optical (NLO) microscopy to the interrogation of stented coronary arteries under different diet and stent deployment conditions. Bare metal stents and Taxus drug-eluting stents (DES) were placed in coronary arteries of Ossabaw pigs of control and atherogenic diet groups. Multimodal NLO imaging was performed to inspect changes in arterial structures and compositions after stenting. Sum frequency generation, one of the multimodalities, was used for the quantitative analysis of collagen content in the peristent and in-stent artery segments of both pig groups. Atherogenic diet increased lipid and collagen in peristent segments. In-stent segments showed decreased collagen expression in neointima compared to media. Deployment of DES in atheromatous arteries inhibited collagen expression in the arterial media.

  1. Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Vejlstrup, Niels Grove; Ahtarovski, Kiril Aleksov;

    2012-01-01

    Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year. This case...... report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology. While...

  2. Successful retrieval of an unexpanded coronary stent from the left main coronary artery during primary percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Šalinger-Martinović Sonja

    2011-01-01

    Full Text Available Introduction. Dislodgement and embolization of the new generation of coronary stents before their deployment are rare but could constitute a very serious complication. Case Outline. We report a case of a stent dislodgement into the left main coronary artery during the primary coronary intervention of infarct related left circumflex artery in a patient with acute myocardial infarction. The dislodged and unexpanded bare-metal stent FlexMaster 3.0x19 mm (Abbot Vascular was stranded and bended in the left main coronary artery (LMCA, probably by the tip of the guiding catheter, but stayed over the guidewire. It was successfully retrieved using a low-profile Ryujin 1.25x15 balloon catheter (Terumo that was passed through the stent, inflated and then pulled back into the guiding catheter. After that, the whole system was withdrawn through the 6 F arterial sheath via the transfemoral approach. After repeated cannulation via the 6F arterial sheath, additional BMW and ATW guidewires were introduced into the posterolateral and obtuse marginal branches and a bare-metal stent Driver (Medtronic Cardiovascular Inc 3.0x18 mm was implanted in the target lesion. Conclusion. Stent dislodgement is a rare but potentially life-threatening complication of the percutaneous coronary intervention. This incident occurring in the LMCA in particular during an acute myocardial infarction requires to be urgently resolved. The avoidance of rough manipulation with the guiding catheter and delivery system may help in preventing this kind of complications.

  3. Drug-eluting versus bare-metal stents in large coronary arteries

    DEFF Research Database (Denmark)

    Kaiser, Christoph; Galatius, Soeren; Erne, Paul

    2010-01-01

    Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether...... this increase in risk was also seen with second-generation drug-eluting stents....

  4. Simulation of stent deployment in a realistic human coronary artery

    NARCIS (Netherlands)

    F.J.H. Gijsen (Frank); F. Migliavacca (Francesco); S. Schievano (Silvia); L. Socci (Laura); L. Petrini (Lorenza); A. Thury (Attila); J.J. Wentzel (Jolanda); A.F.W. van der Steen (Ton); P.W.J.C. Serruys (Patrick); G. Dubini (Gabriele)

    2008-01-01

    textabstractBackground: The process of restenosis after a stenting procedure is related to local biomechanical environment. Arterial wall stresses caused by the interaction of the stent with the vascular wall and possibly stress induced stent strut fracture are two important parameters. The knowledg

  5. In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT

    Energy Technology Data Exchange (ETDEWEB)

    Steen, Henning, E-mail: henning.steen@med.uni-heidelberg.de [University of Heidelberg, Department of Cardiology, Im Neuenheimer Feld 410, Heidelberg 69120 (Germany); Andre, Florian, E-mail: Florian.Andre@med.uni-heidelberg.de [University of Heidelberg, Department of Cardiology, Im Neuenheimer Feld 410, Heidelberg 69120 (Germany); Korosoglou, Grigorios, E-mail: Grigorios.Korosoglou@med.uni-heidelberg.de [University of Heidelberg, Department of Cardiology, Im Neuenheimer Feld 410, Heidelberg 69120 (Germany); Mueller, Dirk, E-mail: Dirk.Mueller@philips.com [Philips GmbH Healthcare Division, Luebeckertordamm 5, Hamburg 20099 (Germany); Hosch, Waldemar, E-mail: Waldemar.Hosch@med.uni-heidelberg.de [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 410, Heidelberg 69120 (Germany); Kauczor, Hans-Ulrich, E-mail: Hans-Ulrich.Kauczor@med.uni-heidelberg.de [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 410, Heidelberg 69120 (Germany); Giannitsis, Evangelos, E-mail: Evangelos.Giannitsis@med.uni-heidelberg.de [University of Heidelberg, Department of Cardiology, Im Neuenheimer Feld 410, Heidelberg 69120 (Germany); Katus, Hugo A., E-mail: Hugo.Katus@med.uni-heidelberg.de [University of Heidelberg, Department of Cardiology, Im Neuenheimer Feld 410, Heidelberg 69120 (Germany)

    2011-10-15

    for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen.

  6. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group.

    OpenAIRE

    Serruys, P.W.; de Jaegere, P; Kiemeneij, F.; Macaya, C; Rutsch, W; Heyndrickx, G.; Emanuelsson, H.; Marco, J.; Legrand, Victor; Materne, P.

    1994-01-01

    BACKGROUND: Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as compared with standard balloon angioplasty. METHODS: A total of 520 patients with stable angina and a single coronary-artery lesion were randomly assigned to either stent implantation (262 patients)...

  7. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar;

    2014-01-01

    BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...

  8. Minimally invasive coronary artery bypass grafting versus stenting for patients with proximal left anterior descending coronary artery disease.

    Science.gov (United States)

    Shirai, Kazuyuki; Lansky, Alexandra J; Mehran, Roxana; Dangas, George D; Costantini, Costantino O; Fahy, Martin; Slack, Steven; Mintz, Gary S; Stone, Gregg W; Leon, Martin B

    2004-04-15

    The purpose of this study was to compare the clinical outcomes of stenting and minimally invasive coronary artery bypass grafting (MIDCAB) in patients with proximal left anterior descending (LAD) coronary artery disease. The Patency, Outcome, Economics of Minimally invasive direct coronary bypass (POEM) study demonstrated that MIDCAB had similar safety and long-term efficacy for LAD revascularization compared with conventional coronary artery bypass grafting. Although LAD stenting is superior to conventional balloon angioplasty, whether it is comparable to MIDCAB is not known. We identified a matched population of 429 consecutive patients with 1-vessel disease who underwent elective proximal LAD stenting and compared their clinical outcomes with those of the 152 patients in the MIDCAB group of the POEM study. The in-hospital event rate was similar in both groups, except for a shorter length of hospital stay with LAD stenting compared with MIDCAB (2.68 vs 4.07 days, p <0.0001). At 6-month follow-up, the incidence of death and Q-wave myocardial infarction or that of cerebrovascular accident was not significantly different between these 2 groups. However, target vessel revascularization was significantly higher with LAD stenting than MIDCAB (13.3% vs 6.6%, p = 0.045). In the subgroup of patients without diabetes, all clinical events were similar in both groups, and the benefit of a shorter hospital stay associated with stenting was maintained. Compared with MIDCAB, LAD stenting is associated with higher repeat revascularization rates but offers the advantage of shorter hospitalization. For nondiabetics with proximal LAD disease, stenting may be the revascularization strategy of choice.

  9. Stenting of unprotected left main coronary artery in a patient with cardiogenic shock

    Directory of Open Access Journals (Sweden)

    Bedson José Lopes de Sá

    1999-09-01

    Full Text Available A 64-year-old female presented with pulmonary edema and cardiogenic shock after coronary arteriography that showed severe suboclusive lesion in the left main coronary artery (LMCA in a dominant left coronary system. The patient succesfully underwent urgent angioplasty with stent deployment in the LMCA. After an uneventful period, the patient was discharged at day six.

  10. Minimally invasive coronary artery bypass grafting versus percutaneous transluminal coronary angioplasty with stenting in isolated high-grade stenosis of the proximal left anterior descending coronary artery : Six months' angiographic and clinical follow-up of a prospective randomized study

    NARCIS (Netherlands)

    Drenth, DJ; Winter, JB; Veeger, NJGM; Monnink, SHJ; van Boven, AJ; Grandjean, JG; Mariani, MA; Boonstra, PW

    Objective: We sought to compare minimally invasive coronary artery bypass grafting (surgical intervention) with percutaneous transluminal coronary angioplasty with primary stenting (stenting) in patients having an isolated high-grade stenosis (American College of Cardiology/American Heart

  11. Safety and efficacy of coronary drug eluting stent for atherosclerotic stenosis of the small renal artery

    Institute of Scientific and Technical Information of China (English)

    LI Chun-jie; WU Zheng; YAN Hong-bing; WANG Jian; ZHAO Han-jun

    2009-01-01

    @@ Small diameter renal artery refers to the renal artery with the cross-section diameter less than 5 mm, the incidence of which is approximately 8%.1 Small diameter renal artery is common in patients with congenital multi-branch renal arteries, diabetes and multi-coronary artery lesions. Renal artery bare-mental stent (BMS) implantation is the standard treatment for ostial renal artery stenosis.2,3 However, the restenosis rate4-6 is too high and becomes one of the relative contraindications for small diameter renal artery stent implantation. Clinical trials (e.g. RAVEL,7,8 SIRIUS9 and TAXUS-IV10) have proved that drug eluting stent (DES), compared with BMS, can reduce the restenosis rate after the percutanous coronary intervention (PCI). And Huda et al11 claimed that DES had the better results than BMS in the treatment of obstructive superficial femoral artery disease. However,there are few studies involved restenosis after the renal artery intervention. We hypothesized that coronary DES applied in renal artery stenosis might inhibit intimal proliferation effectively as in coronary artery disease;therefore we evaluated the results of 25 patients with atherosclerotic renal artery stenosis treated using coronary DES to assess the safety and efficacy of coronary DES in patients with small renal artery stenotic lesions.

  12. Effect of Shuxinyin (舒心饮) on In-Stent Restenosis after Coronary Artery Stenting

    Institute of Scientific and Technical Information of China (English)

    王显; 林钟香; 葛均波; 刘旭; 何燕; 张振贤; 沈琳

    2002-01-01

    Objective: To evaluate the effect of anti-platelet regimens and it's combination with Shuxinyin (SXY, 舒心饮,) on in-stent restenosis after stent implantation. Methods: Forty-four patients with successful stent implantation in a coronary artery were randomly assigned to the treated group (n=20) and the control group (n=24). The treated group received: SXY and anti-platelet therapy. The control group were treated with anti-platelet regimens only. Platelet activation was assessed before and immediately after the stenting by flow cytometry, the expression of P-selectin (CD62P) and glycoprotein(GP) Ⅱb/Ⅲa receptor. It was reassessed on the 30th day after stenting. Plasma fibrinogen (Fg) and C-reaction protein (CRP) were measured by biuret and laser scattering turbidimetry respectively at the same time. Observation was made on the scoring of the symptoms of Qi deficiency syndrome, Qi-Yin deficiency syndrome and blood stasis syndrome in the two groups. Differences between groups were compared. Results: Compared with the control group, combination with SXY and anti-platelet therapy was remarkable in reducing plasma CRP (P<0.05), and also with the tendency to decrease plasma Fg, GPⅡb/Ⅲa and CD62P. It could also evidently decrease the scoring of Qi-Yin deficiency syndrome, Qi deficiency syndrome and blood stasis syndrome after stenting (P<0.05, 0.01, 0.01) respectively. Follow-up survey found 40% relapse of angina pectoris with 4 cases of in-stent restenosis proved by angiography in the treated group. But the relapse of angina pectoris in the control group was 67% with 2 cases of myocardial infarction (MI), 7 cases of in-stent restenosis proved by angiography and one death. Conclusions: Combination with SXY and anti-platelet regimens can prevent stent thrombosis and in-stent restenosis after stent implantation, and it seems superior to anti-platelet therapy only.

  13. The use of coronary stent in hepatic artery stenosis after orthotopic liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Huang Mingsheng [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Shan Hong [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China)]. E-mail: gzshsums@public.guangzhou.gd.cn; Jiang Zaibo [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Li Zhengran [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Zhu Kangshun [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Guan Shouhai [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Qian Jiesheng [Department of Radiology, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Chen Guihua [Transplantation Center, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Lu Minqiang [Transplantation Center, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China); Yang Yang [Transplantation Center, the Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou 510630, Guangdong Province (China)

    2006-12-15

    Purpose: This retrospective study was undertaken to evaluate the effectiveness of coronary stent placement in hepatic artery stenosis after orthotopic liver transplantation (OLT). Materials and methods: Of 430 consecutive adult orthotopic liver transplant recipients between November 2003 and September 2005, 17 had hepatic artery stenosis (HAS). Fourteen of them underwent coronary stent placement in the HAS. The technical results, complications, hepatic artery patency and clinical outcome were reviewed. Results: Technical and immediate success was 100%. After a mean follow-up of 159.4 days (range, 9-375 days), all patients obtained patent hepatic arteries except 2 patients occurred hepatic artery restenoses at 26 and 45 days after stent placement, respectively. Kaplan-Meier curve of patency showed cumulated stent patency at 3, 6, and 12 months of 78%, 58% and 45%, respectively. During the follow-up, 8 patients survived, 5 died of septic multiple-organ failure, 1 received retransplantation because of refractory biliary infection. Hepatic artery dissection induced by a guiding catheter occurred in one patient and was successfully treated with a coronary stent. Conclusion: Hepatic artery stenosis after OLT can be successfully treated with coronary stent placement with low complication rate and an acceptable 1-year hepatic artery patency rate.

  14. Clinicians' contributions to the development of coronary artery stents: a qualitative study of transformative device innovation.

    Directory of Open Access Journals (Sweden)

    Aaron S Kesselheim

    Full Text Available BACKGROUND: Medical device innovation remains poorly understood, and policymakers disagree over how to incentivize early development. We sought to elucidate the components of transformative health care innovation by conducting an in-depth case study of development of a key medical device: coronary artery stents. METHODS AND FINDINGS: We conducted semi-structured interviews with the innovators whose work contributed to the development of coronary artery stents who we identified based on a review of the regulatory, patent, and medical literature. Semi-structured interviews with each participant covered the interviewee's personal involvement in coronary artery stent development, the roles of institutions and other individuals in the development process, the interplay of funding and intellectual property in the interviewee's contribution, and finally reflections on lessons arising from the experience. Transcripts were analyzed using standard coding techniques and the constant comparative method of qualitative data analysis. CONCLUSIONS: We found that the first coronary artery stents emerged from three teams: Julio Palmaz and Richard Schatz, Cesare Gianturco and Gary Roubin, and Ulrich Sigwart. First, these individual physician-inventors saw the need for coronary artery stents in their clinical practice. In response, they developed prototypes with the support of academic medical centers leading to early validation studies. Larger companies entered afterwards with engineering support. Patents became paramount once the technology diffused. The case of coronary stents suggests that innovation policy should focus on supporting early physician-inventors at academic centers.

  15. Next-generation drug-eluting stents in coronary artery disease: focus on everolimus-eluting stent (Xience V®

    Directory of Open Access Journals (Sweden)

    Imad Sheiban

    2008-02-01

    Full Text Available Imad Sheiban1, Gianluca Villata1, Mario Bollati1, Dario Sillano1, Marzia Lotrionte2, Giuseppe Biondi-Zoccai11Interventional Cardiology, Division of Cardiology, University of Turin, Turin, Italy; 2Institute of Cardiology, Catholic University, Rome, ItalyAbstract: Percutaneous coronary revascularization has been a mainstay in the management of coronary artery disease since its introduction in the late 1970s. Bare-metal stents and, more recently, first-generation drug-eluting stents (DES, such as sirolimus-eluting (Cypher® and paclitaxel-eluting stents (Taxus®, have further improved results of percutaneous coronary intervention (PCI by improving early results and reducing the risk of restenosis. There is currently debate on the safety of these first-generation DES, given the potential for late stent thrombosis, especially after discontinuation of dual antiplatelet therapy. There are well known caveats on the performance of their respective metallic stent platforms, delivery, and dilation systems, and polymer coatings. Second-generation DES, such as zotarolimus-eluting (Endeavor® and everolimus-eluting stents (Xience V®, have recently become available in the USA and/or Europe. The Xience V stent holds the promise of superior anti-restenotic efficacy as well as long-term safety. In addition, this stent is based on the Multi-link platform and delivery system. Recently available data already suggest the superiority of the Xience V stent in comparison to the Taxus stent in terms of prevention of restenosis, without significant untoward events. Nonetheless, the number of patients studied and the follow-up duration are still too limited to enable definitive conclusions. Only indirect meta-analyses can be used to date to compare the Xience V with the Cypher. This systematic review tries to provide a concise and critical appraisal of the data in support of the Xience V everolimus-eluting stent.Keywords: coronary artery disease, everolimus, percutaneous

  16. Drug-eluting versus bare-metal stents in large coronary arteries

    DEFF Research Database (Denmark)

    Kaiser, Christoph; Galatius, Soeren; Erne, Paul

    2010-01-01

    Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether...

  17. New stent design for use in small coronary arteries during percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Juan F Granada

    2010-10-01

    Full Text Available Juan F Granada1, Barbara A Huibregtse2, Keith D Dawkins21The Jack H Skirball Center for Cardiovascular Research, Cardiovascular Research Foundation, Columbia University Medical Center, New York, NY, USA; 2Boston Scientific Corporation, Natick, MA, USAAbstract: Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel, and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches, intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001, instent binary restenosis (13.0% versus 38.1%, P < 0.001, and target lesion revascularization (5.8% versus 17.6%, P < 0.001 at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03 and instent binary restenosis (13.0% versus 25.9%, P = 0.02 when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS

  18. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    Science.gov (United States)

    Lee, Cheng-Hung; Jhong, Guan-Heng; Hsu, Ming-Yi; Liu, Shih-Jung; Wang, Chao-Jan; Hung, Kuo-Chun

    2014-05-01

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  19. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter); F. Kiemeneij (Ferdinand); C.M. Miguel (Carlos); W.R. Rutsch (Wolfgang); G.R. Heyndrickx (Guy); H.U. Emanuelsson (Hakan); J. Marco (Jean); V.M.G. Legrand (Victor); P.H. Materne (Phillipe); J.A. Belardi (Jorge); U. Sigwart (Ulrich); A. Colombo (Antonio); J-J. Goy (Jean-Jacques); P.A. van den Heuvel (Paul); J. Delcan; M-A.M. Morel (Marie-Angèle)

    1994-01-01

    textabstractBalloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as c

  20. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease.

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter); F. Kiemeneij (Ferdinand); C.M. Miguel (Carlos); W.R. Rutsch (Wolfgang); G.R. Heyndrickx (Guy); H.U. Emanuelsson (Hakan); J. Marco (Jean); V.M.G. Legrand (Victor); P.H. Materne (Phillipe); J.A. Belardi (Jorge); U. Sigwart (Ulrich); A. Colombo (Antonio); J-J. Goy (Jean-Jacques); P. van den Heuvel; J. Delcan; M-A.M. Morel (Marie-Angèle)

    1994-01-01

    textabstractBACKGROUND. Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical o

  1. Computer modeling of restenosis and heating stent thermal effects in the coronary artery

    OpenAIRE

    Zdravković-Petrović, Nataša; Nikolić, Dalibor; Milošević, Žarko; Themis, Exarchos; Parodi, Oberdan; Filipović, Nenad; id_orcid 0000-0001-9964-5615

    2013-01-01

    The understanding and the prediction of the evolution of atherosclerotic plaques either into vulnerable plaques or into stable plaques are very important for the medical community. Stents in the coronary arteries are routinely used in the management of patients with angina or myocardial infarction where percutaneous coronary intervention is the clinically appropriate procedure. In this study we analysed stent deployment in the specific patient and simulation of the temperature distribution fo...

  2. Quality of life after PCI with drug-eluting stents or coronary-artery bypass surgery

    NARCIS (Netherlands)

    D.J. Cohen (David J.); B.A. van Hout (Ben); P.W.J.C. Serruys (Patrick); F.W. Mohr (Friedrich); C.M. Miguel (Carlos); P. den Heijer (Peter); M.M. Vrakking (M. M.); K.K. Wang (Kenneth); E.M. Mahoney (Elizabeth M.); S. Audi (Salma); K. Leadly (Katrin); K.D. Dawkins (Keith); A.P. Kappetein (Arie Pieter)

    2011-01-01

    textabstractBACKGROUND: Previous studies have shown that among patients undergoing multivessel revascularization, coronary-artery bypass grafting (CABG), as compared with percutaneous coronary intervention (PCI) either by means of balloon angioplasty or with the use of bare-metal stents, results in

  3. Quality of life after PCI with drug-eluting stents or coronary-artery bypass surgery

    NARCIS (Netherlands)

    D.J. Cohen (David J.); B.A. van Hout (Ben); P.W.J.C. Serruys (Patrick); F.W. Mohr (Friedrich); C.M. Miguel (Carlos); P. den Heijer (Peter); M.M. Vrakking (M. M.); K.K. Wang (Kenneth); E.M. Mahoney (Elizabeth M.); S. Audi (Salma); K. Leadly (Katrin); K.D. Dawkins (Keith); A.P. Kappetein (Arie Pieter)

    2011-01-01

    textabstractBACKGROUND: Previous studies have shown that among patients undergoing multivessel revascularization, coronary-artery bypass grafting (CABG), as compared with percutaneous coronary intervention (PCI) either by means of balloon angioplasty or with the use of bare-metal stents, results in

  4. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheng-Hung [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China); Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Jhong, Guan-Heng [Graduate Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan (China); Hsu, Ming-Yi; Wang, Chao-Jan [Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, Taiwan (China); Liu, Shih-Jung, E-mail: shihjung@mail.cgu.edu.tw [Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Hung, Kuo-Chun [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China)

    2014-05-28

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  5. Transradial artery Palmaz-Schatz coronary stent implantation: results of a single-center feasibility study.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J

    1995-07-01

    The purpose of this study was to evaluate the feasibility and safety of implantation of unsheathed Palmaz-Schatz coronary stents introduced via the radial artery. Anticoagulation after coronary stenting carries the risk of vascular complications if large-bore guiding catheters are introduced via the femoral artery. These complications have serious local sequelae and lead to suboptimal anticoagulation and prolonged hospitalization. By combining 6F guiding catheters and low-profile dilatation catheters mounted with Palmaz-Schatz stents, smaller vessels such as the radial artery can be selected as the entry site. It is hypothesized that with this technique major puncture site-related complications rarely occur because hemostasis is easily achieved and because no veins and nerves are near this artery. With the double blood supply to the hand, radial artery occlusion is well tolerated. In 100 consecutive patients, stent implantation was attempted for 122 lesions in 104 vessels. Immediately after stent implantation and final angiography, the introducer sheath was withdrawn and intense anticoagulation and mobilization initiated. The radial artery puncture site was studied by two-dimensional and Doppler ultrasound. Successful stent implantation via the radial artery was achieved in 96 patients. In 2 patients, arterial puncture failed but was followed by successful stenting via another entry site. In 1 patient, stent implantation was achieved with a stent delivery system via the femoral artery after a failed attempt to cross the lesion with a bare stent via the radial approach, complicated by groin bleeding requiring transfusions and vascular surgery.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. The Development of Coronary Artery Stents: From Bare-Metal to Bio-Resorbable Types

    Directory of Open Access Journals (Sweden)

    Ming-Yun Ho

    2016-07-01

    Full Text Available Coronary artery disease is the leading cause of death worldwide. Conventional balloon angioplasty is associated with high rates of complications such as coronary dissection and vessel recoil. The deployment of bare-metal stents (BMSs can overcome these problems and achieve a better patency rate than simple balloon angioplasty. It has been shown that the stent design including structure platform, size, length, and strut thickness has a major influence on the clinical results. Even though angioplasty with BMS implantation is widely used in coronary interventions, the restenosis rate due to neointimal hyperplasia remains high. Therefore, drug-eluting stents (DESs coated with anti-proliferative agents and polymers have been developed to reduce the restenosis rate and improve the clinical outcomes. Although the repeat revascularization rate of DESs is lower than that of BMSs, the long-term stent thrombosis rate is higher than for BMSs. Therefore, new and emerging generations of stents, in which, for example, thinner struts and bioresorbable polymers are used, are available for clinical use. However, there are only a limited number of clinical trials, in which these newer stents have been compared with BMSs and first- and second-generation DESs. The purpose of this review was to provide up-to-date information on the evolution of coronary artery stents from BMSs to DESs to bioresorbable stents (BRSs.

  7. Optical coherence tomography assessment of edge dissections after drug-eluting stent implantation in coronary artery

    Institute of Scientific and Technical Information of China (English)

    GUO Jun; HAN Bao-shi; GAI Lu-yue; YANG Ting-shu; CHEN Yun-dai; TIAN Feng; LIU Hong-bin; CHEN Lian; SUN Zhi-jun; REN Yi-hong; JIN Qin-hua; LIU Chang-fu

    2012-01-01

    Background Edge dissections after coronary stent implantation are associated with increased short-term risk of major adverse cardiovascular events.The incidence and outcome of edge dissections after coronary stent implantation were reportedly different using different imaging techniques.We used optical coherence tomography (OCT) to assess the incidence,morphological findings and related factors of edge dissections after drug-eluting stent (DES) implantation.Methods Totally 42 patients with 43 de novo lesions in 43 native arteries undergoing DES implantation with OCT imaging were enrolled in this study.Results Nine edge dissections were detected in 43 arteries after DES implantation.There were four morphological patterns of stent edge dissections indentified in this study:(1) superficial intimal tears (n=3),(2) subintimal dissections (n=4),(3) split of media (n=1),(4) disruption of the fibrotic cap of plaque (n=1).Stent edge expansion and stent expansion were both higher in the group with dissections than those in the group without dissections (1.682±0.425 vs.1.229±0.285,P=0.0290; 1.507±0.445 vs.1.174±0.265,P=0.0072).Conclusions The incidence of stent edge dissections detected by OCT was 21%.Stent edge dissection is related with stent edge expansion and stent expansion.

  8. Primary stenting of occluded native coronary arteries: final results of the Primary Stenting of Occluded Native Coronary Arteries (PRISON) study.

    Science.gov (United States)

    Rahel, Braim M; Suttorp, Maarten J; Laarman, Gert J; Kiemeneij, Ferdinand; Bal, Egbert T; Rensing, Benno J; Ernst, Sjef M P G; ten Berg, Jurriën M; Kelder, Johannes C; Plokker, H W Thijs

    2004-05-01

    Primary intracoronary stent placement after successfully crossing chronic total coronary occlusions may decrease the high restenosis rate at long-term follow-up compared with conventional balloon angioplasty. In a prospective, randomized trial, balloon angioplasty was compared with stent implantation for the treatment of chronic total occlusions. Patients were followed for 12 months with angiographic follow-up at 6 months. Quantitative coronary analysis was performed by an independent core lab. A total of 200 patients were enrolled. Baseline characteristics were evenly distributed. After the procedure the mean minimal luminal diameter in the conventional group was 2.34 +/- 0.46 mm versus 2.90 +/- 0.41 mm in the stented group (P 50% diameter stenosis) was seen in 33% in the conventional group versus 22% in the stented group (P =.137). The reocclusion rates were 7.3% and 8.2%, respectively (P = 1.00). At 12 month follow-up, the rate of target lesion revascularization was significantly higher in the conventional group (29% versus 13%, P <.0001). These data demonstrate that stenting of chronic total occlusions is superior to balloon angioplasty alone with a statistically significant reduction in the need for target lesion revascularization and a lower, but not significant, restenosis rate.

  9. The benefits of drug-eluting stents in the treatment of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Kiramijyan S

    2016-03-01

    Full Text Available Sarkis Kiramijyan,1 Ming W Liu2 1Division of Cardiology, Department of Medicine, Harbor-UCLA Medical Center, Torrance, CA, USA; 2Heart and Vascular Care Center, White Memorial Medical Center, Los Angeles, CA, USA Abstract: The advent of coronary stents has been a landmark development in the treatment of coronary artery disease with percutaneous coronary intervention. Initial percutaneous treatment using balloon angioplasty alone had limited clinical efficacy due to immediate vascular elastic recoil and dissection, in addition to late negative vascular remodeling and neointimal hyperplasia. With the introduction of coronary stents, initially bare-metal stents (BMS, the problems of dissection and negative remodeling due to injury in addition to vascular elastic recoil were eliminated; however, neointimal hyperplasia remained an ongoing obstacle in the long-term efficacy of stents. Neointimal hyperplasia resulted in in-stent restenosis in 20%–30% of cases after intervention with BMS, which led to high rates of target lesion revascularization. Subsequently, drug-eluting stents (DES were introduced, which had the added advantage of releasing an anti-proliferative drug from the stent to reduce the neointimal proliferation, thus resulting in the reduction of the rates of in-stent restenosis. Although the first-generation DES had significantly improved outcomes over its predecessor, the BMS, several challenges including stent thrombosis and delayed endothelialization of the stent remained. The second-generation DES have been significantly improved over their first-generation predecessors in regard to efficacy and safety, ie, improved long-term outcomes and significant reductions in stent thrombosis. The duration of dual antiplatelet therapy after DES has also been studied extensively in multiple large trials. A newer generation of stents, including those with bioresorbable polymers, polymer-free, and fully bioresorbable scaffolds is still in the early

  10. Percutaneous transradial artery approach for coronary Palmaz-Schatz stent implantation.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J

    1994-07-01

    The purpose of this study was to evaluate feasibility, safety, and efficacy of implantation of unsheathed Palmaz-Schatz coronary stents via the radial artery. Anticoagulation after coronary stenting has the hazard of vascular complications if large-bore guiding catheters are introduced via the femoral artery. Such complications have serious local sequelae, are associated with suboptimal anticoagulation, and prolong hospitalization. By combining 6F guiding catheters and low-profile dilatation catheters with bare Palmaz-Schatz stents, smaller vessels such as the radial artery can be selected as the entry site. It is postulated that no major puncture site-related complications occur because hemostasis is easily achieved and no veins and nerves are near the radial artery. With double blood supply to the hand, radial artery occlusion is well tolerated. Twenty-five bare Palmaz-Schatz stents were implanted via the radial artery through 6F guiding catheters in 20 consecutive patients for venous bypass graft stenosis (n = 9; 45%), native coronary artery restenosis (n = 7; 35%) and suboptimal transradial artery PTCA (n = 4; 20%). Immediately after stent implantation and assessment of the result by means of computerized quantitative coronary analysis, the arterial sheath was withdrawn followed by intense anticoagulation and free ambulation of the patient. Radial artery function and anatomy were assessed by two-dimensional and Doppler ultrasound examination. Lesions (n = 24) were of type A (n = 13; 54%), B (n = 6; 25%) and C (n = 5; 21%). The reference diameter of the stented segments was 3.2 +/- 0.5 mm (2.2 to 4.2 mm).(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Stent implantation of left main coronary artery stenosis in an infant: Effective long-term treatment?

    Directory of Open Access Journals (Sweden)

    Christian Paech

    2015-01-01

    Full Text Available Coronary artery stenosis is a rare phenomenon in children. Coronary stent implantation is generally not considered a standard treatment option due to technical difficulties and potential complications in this group of patients. Nevertheless, several pediatric cases reporting successful implantation with acceptable short-term experiences have been described. The following case presents a successful stent implantation for left main coronary artery (LMCA stenosis early after surgery for anomalous left coronary artery from pulmonary artery (ALCAPA at the age of 6 months. The excellent mid-term results and notably the procedure′s potential as a long-term treatment in small children are highlighted. A 6-month-old infant underwent surgery for ALCAPA. Due to sudden postoperative deterioration, cardiac catheterization was performed. Coronary angiography revealed severe (90% ostial LMCA stenosis. A PROMUS drug-eluting stent (Promus Element AL3.0 Χ 8 mm, Boston Scientific, Natick, Massachusetts, USA was implanted. The procedure was performed without complications. Antiplatelet therapy with acetylsalicylic acid and clopidogrel was initiated. Subsequently, cardiac function improved slowly. Cardiac catheterization 3 years 8 months after stent implantation showed no restenosis with a proximal LMCA diameter still at the 50 th percentile for age. Neither were signs of heart failure reported at the last follow-up at 7 years of age. Presupposing normal growth, the implanted stent would thus provide sufficient myocardial perfusion with a LMCA lumen at the 40 th percentile at the age of 16 years. In selected cases, coronary stent implantation may be an effective mid- to long-term treatment of coronary artery stenosis even in very young children.

  12. A novel platinum chromium everolimus-eluting stent for the treatment of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Bennett J

    2013-06-01

    Full Text Available Johan Bennett, Christophe DuboisDepartment of Cardiovascular Diseases, University Hospitals Leuven, Leuven, BelgiumAbstract: The development of coronary stents represents a major step forward in the treatment of obstructive coronary artery disease since the introduction of percutaneous coronary intervention. The initial enthusiasm for bare metal stents was, however, tempered by a significant incidence of in-stent restenosis, the manifestation of excessive neointima hyperplasia within the stented vessel segment, ultimately leading to target vessel revascularization. Later, drug-eluting stents, with controlled local release of antiproliferative agents, consistently reduced this need for repeat revascularization. In turn, the long-term safety of first-generation drug-eluting stents was brought into question with the observation of an increased incidence of late stent thrombosis, often presenting as myocardial infarction or sudden death. Since then, new drugs, polymers, and platforms for drug elution have been developed to improve stent safety and preserve efficacy. Development of a novel platinum chromium alloy with high radial strength and high radiopacity has enabled the design of a new, thin-strut, flexible, and highly trackable stent platform, while simultaneously improving stent visibility. Significant advances in polymer coating, serving as a drug carrier on the stent surface, and in antiproliferative agent technology have further improved the safety and clinical performance of newer-generation drug-eluting stents. This review will provide an overview of the novel platinum chromium everolimus-eluting stents that are currently available. The clinical data from major clinical trials with these devices will be summarized and put into perspective.Keywords: drug-eluting stent, restenosis, Promus Element, Synergy

  13. Patient with Recent Coronary Artery Stent Requiring Major Non Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Usha Kiran

    2009-01-01

    Full Text Available Anaesthesiologists are increasingly confronted with patients who had a recent coronary artery stent implanta-tion and are on dual anti-platelet medication. Non cardiac surgery and most invasive procedures increase the risk of stent thrombosis especially when procedure is performed early after stent implantation. Anaesthesiologist faces the dilemma of stopping the antiplatelet therapy before surgery to avoid bleeding versus perioperative stent thrombosis. Individualized approach should be adopted with following precautions. i In a surgical patient with a history of percu-taneous coronary intervention (PCI and coronary stent, determine the date of the procedure, the kind of the stent inserted and the possibility of complications during the procedure. ii Consider all patents with a recent stent implan-tation (e.g. less than three months for bare metal stents and less than one year for brachytherapy or drug eluting stents as high risk and consult an interventional cardiologist. iii Any decision to postpone surgery, continue, modify or discontinue antiplatelet regimes must involve the cardiologist, anaesthesiologist, surgeon, haematologist and the intensivist to balance the risk and benefit of each decision.

  14. Biocompatibility of Coronary Stents

    Directory of Open Access Journals (Sweden)

    Thamarasee M. Jeewandara

    2014-01-01

    Full Text Available Cardiovascular disease is the dominant cause of mortality in developed countries, with coronary artery disease (CAD a predominant contributor. The development of stents to treat CAD was a significant innovation, facilitating effective percutaneous coronary revascularization. Coronary stents have evolved from bare metal compositions, to incorporate advances in pharmacological therapy in what are now known as drug eluting stents (DES. Deployment of a stent overcomes some limitations of balloon angioplasty alone, but provides an acute stimulus for thrombus formation and promotes neointimal hyperplasia. First generation DES effectively reduced in-stent restenosis, but profoundly delay healing and are susceptible to late stent thrombosis, leading to significant clinical complications in the long term. This review characterizes the development of coronary stents, detailing the incremental improvements, which aim to attenuate the major clinical complications of thrombosis and restenosis. Despite these enhancements, coronary stents remain fundamentally incompatible with the vasculature, an issue which has largely gone unaddressed. We highlight the latest modifications and research directions that promise to more holistically design coronary implants that are truly biocompatible.

  15. Rescue AVE Stent Placement for Left Anterior Descending Coronary Artery Occlusion During Diagnostic Angiography.

    Science.gov (United States)

    van Dijk D; Ernst; Six; Plokker

    1996-06-01

    In a 65-year-old male with coronary artery disease a proximal occlusion of the left anterior descending coronary artery occurred during diagnostic coronary angiography. The most likely cause was an occlusive dissection. This resulted in acute myocardial ischemia and immediate cardiogenic shock. The decision was made to proceed to emergency percutaneous transluminal coronary angioplasty (PTCA). After balloon dilatation, a 3.5 mm AVE stent was deployed successfully at the site of the lesion. This resulted in a satisfactory angiographic result and an immediate improvement of the clinical picture. We conclude that placement of an AVE stent can provide a means for restoring flow in case of acute occlusive dissection during coronary angiography.

  16. Computational Modelling of Multi-folded Balloon Delivery Systems for Coronary Artery Stenting: Insights into Patient-Specific Stent Malapposition.

    Science.gov (United States)

    Ragkousis, Georgios E; Curzen, Nick; Bressloff, Neil W

    2015-08-01

    Despite the clinical effectiveness of coronary artery stenting, percutaneous coronary intervention or "stenting" is not free of complications. Stent malapposition (SM) is a common feature of "stenting" particularly in challenging anatomy, such as that characterized by long, tortuous and bifurcated segments. SM is an important risk factor for stent thrombosis and recently it has been associated with longitudinal stent deformation. SM is the result of many factors including reference diameter, vessel tapering, the deployment pressure and the eccentric anatomy of the vessel. For the purpose of the present paper, virtual multi-folded balloon models have been developed for simulated deployment in both constant and varying diameter vessels under uniform pressure. The virtual balloons have been compared to available compliance charts to ensure realistic inflation response at nominal pressures. Thereafter, patient-specific simulations of stenting have been conducted aiming to reduce SM. Different scalar indicators, which allow a more global quantitative judgement of the mechanical performance of each delivery system, have been implemented. The results indicate that at constant pressure, the proposed balloon models can increase the minimum stent lumen area and thereby significantly decrease SM.

  17. Surface chemical and physical modification in stent technology for the treatment of coronary artery disease.

    Science.gov (United States)

    Nazneen, Feroze; Herzog, Grégoire; Arrigan, Damien W M; Caplice, Noel; Benvenuto, Pasquale; Galvin, Paul; Thompson, Michael

    2012-10-01

    Coronary artery disease (CAD) kills millions of people every year. It results from a narrowing of the arteries (stenosis) supplying blood to the heart. This review discusses the merits and limitations of balloon angioplasty and stent implantation, the most common treatment options for CAD, and the pathophysiology associated with these treatments. The focus of the review is heavily placed on research efforts geared toward the modification of stent surfaces for the improvement of stent-vascular compatibility and the reduction in the occurrence of related pathophysiologies. Such modifications may be chemical or physical, both of which are surveyed here. Chemical modifications may be passive or active, while physical modification of stent surfaces can also provide suitable substrates to manipulate the responses of vascular cells (endothelial, smooth muscle, and fibroblast). The influence of micro- and nanostructured surfaces on the in vitro cell response is discussed. Finally, future perspectives on the combination of chemical and physical modifications of stent surfaces are also presented.

  18. Coronary artery bypass surgery or coronary stenting in diabetic patients: too soon to make a statement?

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Alfredo E., E-mail: arodriguez@centroceci.com.ar

    2014-11-15

    Diabetic patients have been associated with poor procedural and long term outcome if they were treated either with percutaneous coronary interventions or coronary artery bypass surgery. Recently several randomized clinical trials (RCT) in this subset of patients have been published showing a greater incidence of major adverse cardiovascular events, death/myocardial infarction/stroke, if they were treated with first generation drug eluting stents (DES) which was not observed previously in the bare metal stent era. However, almost simultaneously with this data, several RCT demonstrated better safety profile with new generation DES including biocompatible polymers, biodegradable polymers and lately complete absorbable DES, all of them showed reduction in adverse cardiac events compared to 1st generation DES in patients with diabetes. In this editorial we review the old and new randomized data in diabetic patients and conclude that there are many unresolved issues to make a definitive statement regarding which is the best revascularization preference in diabetic patients and the measured final efficacy of PCI and CABG will not be reached until the arrival of RCT using next generation DES, including complete absorbable scaffolds. - Highlights: • Diabetic patients have been associated with poor procedural and long term outcome if they were treated either with percutaneous coronary interventions or coronary artery bypass surgery. Recently several randomized clinical trials (RCT) in this subset of patients have been published showing a greater incidence of major adverse cardiovascular events, death/myocardial infarction/stroke, if they were treated with first generation drug eluting stents (DES) which was not observed previously in the bare metal stent era. • In recent years, several RCT demonstrated better safety profile with new generation DES including biocompatible polymers, biodegradable polymers and lately complete absorbable DES, all of them showed reduction in

  19. Long-term outcome in patients treated with sirolimus-eluting stents in complex coronary artery lesions

    DEFF Research Database (Denmark)

    Kelbaek, Henning; Kløvgaard, Lene; Helqvist, Steffen;

    2008-01-01

    data of the long-term outcome of patients with complex coronary artery lesions. METHODS: We randomly assigned 322 patients with total coronary occlusions or lesions located in bifurcations, ostial, or angulated segments of the coronary arteries to have SES or BMS implanted. RESULTS: At 3 years, major...... benefit was observed up to 3 years after implantation of SES in patients with complex coronary artery lesions. The rate of late adverse events was similar in the 2 groups, and stent thromboses occurred rarely after 1 year. (Sirolimus Eluting Stents in Complex Coronary Lesions [SCANDSTENT]; NCT00151658)...

  20. Local Angiopeptin Delivery Using Coated Stents Reduces Neointimal Proliferation in Overstretched Porcine Coronary Arteries.

    Science.gov (United States)

    De Scheerder I; Wilczek; Van Dorpe J; Verbeken; Cathapermal; Wang; Desmet; Schacht; Foegh; De Geest H; Piessens

    1996-06-01

    BACKGROUND: Systemic administration of angiopeptin has been shown to inhibit myointimal thickening after arterial injury in several animal species. METHODS AND RESULTS: To explore to what extent high and long-lasting local concentrations of angiopeptin influence the healing process after vascular injury, tantalum balloon-expandable stents were first coated with a polymer loaded with angiopeptin 250 µg. Implantation of these stents in porcine coronary arteries resulted in tissue concentrations of 10.7 pg/ml wet weight in the stented arterial segment 24 hours after stent implantation, gradually declining to 2.0 pg/ml wet weight at day 8. Finally, 20 pigs were randomly treated with either an angiopeptin-loaded or a blank-coated stent. At baseline, the angiographic parameters were similar between both groups but, after 6 weeks, the minimal luminal diameter of the stented arterial segment was larger in the angiopeptin-treated pigs when compared to controls (2.20 +/- 0.57 mm vs 1.57 +/- 0.68 mm, p < 0.01) This angiographic finding was confirmed by post-mortem morphometry where the respective lumen area values were 1.00 +/- 0.54 mm2 and 0.43 +/- 0.28 mm2 (p < 0.01). CONCLUSION: Polymer coated stents can be loaded with angiopeptin, which after implantation in porcine right coronary arteries result in high local tissue concentrations gradually declining over more than 8 days. These high local concentrations inhibit myointimal proliferation induced by poly(organo)phosphazene coated overstretched stents.

  1. On the necessity of modelling fluid-structure interaction for stented coronary arteries.

    Science.gov (United States)

    Chiastra, Claudio; Migliavacca, Francesco; Martínez, Miguel Ángel; Malvè, Mauro

    2014-06-01

    Although stenting is the most commonly performed procedure for the treatment of coronary atherosclerotic lesions, in-stent restenosis (ISR) remains one of the most serious clinical complications. An important stimulus to ISR is the altered hemodynamics with abnormal shear stresses on endothelial cells generated by the stent presence. Computational fluid dynamics is a valid tool for studying the local hemodynamics of stented vessels, allowing the calculation of the wall shear stress (WSS), which is otherwise not directly possible to be measured in vivo. However, in these numerical simulations the arterial wall and the stent are considered rigid and fixed, an assumption that may influence the WSS and flow patterns. Therefore, the aim of this work is to perform fluid-structure interaction (FSI) analyses of a stented coronary artery in order to understand the effects of the wall compliance on the hemodynamic quantities. Two different materials are considered for the stent: cobalt-chromium (CoCr) and poly-l-lactide (PLLA). The results of the FSI and the corresponding rigid-wall models are compared, focusing in particular on the analysis of the WSS distribution. Results showed similar trends in terms of instantaneous and time-averaged WSS between compliant and rigid-wall cases. In particular, the difference of percentage area exposed to TAWSS lower than 0.4Pa between the CoCr FSI and the rigid-wall cases was about 1.5% while between the PLLA cases 1.0%. The results indicate that, for idealized models of a stented coronary artery, the rigid-wall assumption for fluid dynamic simulations appears adequate when the aim of the study is the analysis of near-wall quantities like WSS.

  2. Long-term clinical effects of magnetic resonance imaging in patients with coronary artery stent implantation.

    Science.gov (United States)

    Kaya, Mehmet Gungor; Okyay, Kaan; Yazici, Huseyin; Sen, Nihat; Tavil, Yusuf; Turkoglu, Sedat; Timurkaynak, Timur; Ozdemir, Murat; Cemri, Mustafa; Yalcin, Ridvan; Cengel, Atiye

    2009-03-01

    We sought to investigate the early and late effects of magnetic resonance imaging (MRI) on stent thrombosis and major adverse coronary events after coronary artery stent (CAS) implantation at a long-term follow-up period. Forty-three patients (28 men, mean age 63+/-10 years) who underwent CAS implantation before MRI examination were included. MRI was performed on a 1.5-T MR-system with a phased array multicoil. An average of 1.3 stents per patient were implanted (1-4 stents). More than one MRI was performed for two patients. Patients who underwent MRI within 8 weeks after the procedure were included in the early-term group (17 patients), and those who underwent MRI after 8 weeks were included in the late-term group (26 patients). Mean follow-up period was 36+/-15 months. There was no acute or subacute stent thrombosis. Late stent thrombosis that resulted in acute myocardial infarction was observed in a patient from the early group after an operation for prostate hyperplasia 5 months after MRI, and the patient underwent percutaneous coronary artery angioplasty. De-nova lesion was observed in four patients in the early group and two patients in the late group (P=0.14). In-stent restenosis was recorded in two patients in the early group and three patients in the late group (P=0.98). Composite major adverse cardiac events (acute coronary syndrome, myocardial infarction, death, and cerebrovascular event) were observed in seven of the early-group patients (41%), and in six of the late-group patients (23%) (P=0.20). MRI can be safely performed in patients with CAS implantation both in the early and late course, and is not associated with an increased risk of major adverse clinical cardiac events at long-term follow-up.

  3. Use of Drug-Eluting Stents in Patients With Coronary Artery Disease and Renal Insufficiency

    Science.gov (United States)

    El-Menyar, Ayman A.; Al Suwaidi, Jassim; Holmes, David R.

    2010-01-01

    Renal insufficiency (RI) has been shown to be associated with increased major adverse cardiovascular events after percutaneous coronary intervention. We reviewed the impact of RI on the pathogenesis of coronary artery disease and outcomes after percutaneous coronary intervention in the form of drug-eluting stent (DES) implantation in these high-risk patients. We searched the English-language literature indexed in MEDLINE, Scopus, and EBSCO Host research databases from 1990 through January 2009, using as search terms coronary revascularization, drug-eluting stent, and renal insufficiency. Studies that assessed DES implantation in patients with various degrees of RI were selected for review. Most of the available data were extracted from observational studies, and data from randomized trials formed the basis of a post hoc analysis. The outcomes after coronary revascularization were less favorable in patients with RI than in those with normal renal function. In patients with RI, DES implantation yielded better outcomes than did use of bare-metal stents. Randomized trials are needed to define optimal treatment of these high-risk patients with coronary artery disease. PMID:20118392

  4. Towards a self-reporting coronary artery stent--measuring neointimal growth associated with in-stent restenosis using electrical impedance techniques.

    Science.gov (United States)

    Shedden, Laurie; Kennedy, Simon; Wadsworth, Roger; Connolly, Patricia

    2010-10-15

    Implantable medical devices have become the standard method for treating a variety of cardiovascular diseases (NICE, 2003, 2009), such as coronary artery disease, where coronary artery stents are the device of choice (Fischman et al., 1994; Babapulle et al., 2004). One post-operative problem with these devices is the long-term monitoring of the device-tissue interface, with respect to the complications that often arise from in-stent restenosis. This monitoring, where it is available, is currently performed using imaging techniques such as contrast angiography, IVUS, CT and MRI. In this study we propose an alternative method for the non-invasive monitoring of restenosis in coronary artery stents. This preliminary study uses impedance spectroscopy to measure the electrical impedance of cells and tissues associated with the neointimal growth that characterises in-stent restenosis in coronary artery stents. An in vitro organ culture model, using a stent implanted in a section of pig coronary artery, simulated tissue growth inside a stent. Impedance measurements were made regularly over a 28-day culture period. In a novel step, the stent itself was employed as an electrode. Differences in electrical impedance could be seen between control (stent alone) and artery-embedded stents in culture, which were associated with the presence of biological tissue. This method could potentially be developed to produce a stent that was capable of self-reporting in-stent restenosis. The advantages of such a device would be that monitoring could be non-invasively and easily carried out, allowing more routine follow-ups and the early identification and management of any device complications.

  5. High-definition computed tomography for coronary artery stents imaging: Initial evaluation of the optimal reconstruction algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Xiaoming, E-mail: mmayzy2008@126.com; Li, Tao, E-mail: litaofeivip@163.com; Li, Xin, E-mail: lx0803@sina.com.cn; Zhou, Weihua, E-mail: wangxue0606@gmail.com

    2015-05-15

    Highlights: • High-resolution scan mode is appropriate for imaging coronary stent. • HD-detail reconstruction algorithm is stent-dedicated kernel. • The intrastent lumen visibility also depends on stent diameter and material. - Abstract: Objective: The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Materials and methods: Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. Results: The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0 ± 8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Conclusions: Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement.

  6. Stenting for left main stenosis in a child with anomalous origin of left coronary artery: case report

    Institute of Scientific and Technical Information of China (English)

    CHEN Ming; HONG Tao; HUO Yong

    2005-01-01

    @@ Anomalous left coronary artery (LCA) arising from right cusp is an uncommon condition. Clinical evidence has shown that this coronary anomaly is consistently related to sudden death. Current treatment options include modification of behaviour, medicine or surgery. Stents have been successfully applied for left main stenosis for a decade. We report a case of LCA arising from right cusp with left main stenosis treated with coronary stent in a child patient.

  7. Experience with the Treatment of Patients with Arterial Hypertension and Concomitant Atrial Fibrillation Stented for Coronary Stenoses and Atherothombosis

    OpenAIRE

    Seredyuk, N.M.; Vakaliuk, I.P.; Yakymchuk, V.M.; Kupnovytska, I.G.; Volynskiy, A.I.; Petrovskiy, R.V.; Sorohtey, L.V.

    2017-01-01

    Material and methods. This study included 1008 patients with arterial hypertension (AH) in combination with coronary artery disease (CAD) and atrial fibrillation (AF). All patients underwent selective coronary angiography, dynamic measurement of blood pressure (BP), recording an electrocardiogram, echocardiogram, coagulogram, lipid profile and other clinical and biochemical studies. Results. For the first time, it was found that comorbidity of AH, CAD and AF after coronary artery stenting for...

  8. Late and very late stent thrombosis following drug-eluting stent implantation in unprotected left main coronary artery: A multicentre registry

    NARCIS (Netherlands)

    A. Chieffo (Alaide); S.-J. Park (Seung-Jung); E. Meliga (Emanuele); I. Sheiban (Imad); M.S. Lee (Michael); A. Latib (Azeem); Y.-H. Kim (Young-Hak); M. Valgimigli (Marco); D. Sillano (Dario); V. Magni (Valeria); G.G. Biondi-Zoccai (Giuseppe); M. Montorfano (Matteo); F. Airoldi (Flavio); R. Rogacka (Renata); M. Carlino (Mauro); I. Michev (Iassen); M.K. Hong (Myeong); C. Moretti (Claudio); E. Bonizzoni (Erminio); G.M. Sangiorgi (Giuseppe); J. Tobis (Jonathan); P.W.J.C. Serruys (Patrick); A. Colombo (Antonio)

    2008-01-01

    textabstractAims: To evaluate the occurrence of late and very late stent thrombosis (ST) following elective drug-eluting stent (DES) implantation in unprotected left main coronary artery (LMCA) stenosis in a large multicentre registry. Methods and results: All 731 consecutive patients who had siroli

  9. Stenting of "unprotected" left main coronary artery stenoses: early and late results.

    Science.gov (United States)

    Laruelle, C J; Brueren, G B; Ernst, S M; Bal, E T; Mast, G E; Suttorp, M J; Brutel de la Rivière, A; Plokker, T H

    1998-02-01

    To assess short and long term efficacy of coronary stent implantation for unprotected left main coronary artery stenosis. Retrospective follow up study. Tertiary referral centre for interventional cardiology and cardiac surgery. Eighteen consecutive patients (12 men; age 70.8 years) between May 1993 and July 1996. Ten patients presented with stable angina and underwent the procedure electively, eight patients presented either with unstable angina or myocardial infarction and underwent the procedure in emergency. Johnson and Johnson Palmaz-Schatz stents were used in 16 patients, and a Microstent and a Gianturco-Roubin in one patient each. An intra-aortic balloon pump was prophylactively used for two patients in the elective group. In the acute group, six required an intra-aortic balloon pump. Procedural success rate and major adverse cardiac events. Successful stent implantation was achieved in all patients. In the elective group, no major adverse cardiac event occurred during the procedure, but one patient had to undergo repeated angioplasty before discharge. All patients of the elective group were discharged alive and there has been one non-cardiac death during a follow up of (mean (SD)) 10 (4) months. In the emergency group, one patient died during the procedure, one patient developed a non Q-wave myocardial infarction, one patient underwent emergency coronary bypass surgery, while another patient died suddenly before hospital discharge. Six patients of the emergency group were discharged alive and there has been one non-cardiac death during a follow up of 7 (4) months. Elective stent implantation for unprotected left main coronary artery stenosis is safe and effective in selected stable patients. Urgent stent implantation, however, cannot be considered as a definitive procedure in emergency situation.

  10. Optimal scanning protocols of 64-slice CT angiography in coronary artery stents: An in vitro phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Almutairi, Abdulrahman Marzouq [Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, Perth, Western Australia (Australia); Sun Zhonghua [Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, Perth, Western Australia (Australia)], E-mail: z.sun@curtin.edu.au; Ng, Curtise [Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, Perth, Western Australia (Australia); Al-Safran, Zakariya A.; Al-Mulla, Abeer A.; Al-Jamaan, Abdulaziz I. [Department of Medical Imaging, King Fahad Specialist Hospital, Dammam (Saudi Arabia)

    2010-04-15

    Purpose: The purpose of the study was to investigate the optimal scanning protocol of 64-slice CT angiography for assessment of coronary artery stents based on a phantom study. Materials and methods: Coronary stents with a diameter of 2.5 mm was implanted in thin plastic tubes with an inner diameter of 3.0 mm to simulate a coronary artery. The tubes were filled with iodinated contrast medium diluted to 178 HU, closed at both ends and positioned in a plastic container filled with vegetable oil (-70 to -100 HU). A series of scans were performed with a 64-slice CT scanner with the following protocols: section thickness: 0.67 mm, 1.0 mm, 1.5 mm, 2.0 mm, pitch value: 0.2, 0.3, 0.5 and reconstruction interval of 50% overlap of the section thickness. 2D axial and multiplanar reformatted images were generated to assess the visibility of stent lumen, while virtual intravascular endoscopy (VIE) was reconstructed to evaluate the artery wall and stent surface. Results: Our results showed that a scanning protocol of 1.0 mm slice thickness with a pitch of 0.3 produced acceptable images with best demonstration of the intrastent lumen and stent surface with minimal image noise or artifacts. In contrast, submillimeter scans with 0.67 mm resulted in moderate artifacts which affected visualization of the coronary lumen, in addition to the increased noise. When the section thickness increased to 1.5 mm and 2.0 mm, visualization of the artery wall and stent surface was compromised, although the intrastent lumen was still visible. Conclusion: Our in vitro study suggested that a scanning protocol of 1.0 mm section thickness with pitch of 0.3 is the optimal protocol for evaluation of coronary artery stents as it allows generation of acceptable images with better visualization of stent lumen, stent surface and coronary artery wall.

  11. Pitavastatin-incorporated nanoparticle-eluting stents attenuate in-stent stenosis without delayed endothelial healing effects in a porcine coronary artery model.

    Science.gov (United States)

    Tsukie, Noriaki; Nakano, Kaku; Matoba, Tetsuya; Masuda, Seigo; Iwata, Eiko; Miyagawa, Miho; Zhao, Gang; Meng, Wei; Kishimoto, Junji; Sunagawa, Kenji; Egashira, Kensuke

    2013-01-01

    The use of currently marketed drug-eluting stents presents safety concerns including increased late thrombosis, which is thought to result mainly from delayed endothelial healing effects (impaired re-endothelialization resulting in abnormal inflammation and fibrin deposition). We recently developed a bioabsorbable polymeric nanoparticle (NP)-eluting stent using a novel cationic electrodeposition technology. Statins are known to inhibit the proliferation of vascular smooth muscle cells (VSMC) and to promote vascular healing. We therefore hypothesized that statin-incorporated NP-eluting stents would attenuate in-stent stenosis without delayed endothelial healing effects. Among six marketed statins, pitavastatin (Pitava) was found to have the most potent effects on VSMC proliferation and endothelial regeneration in vitro. We thus formulated a Pitava-NP-eluting stent (20µg Pitava per stent). In a pig coronary artery model, Pitava-NP-eluting stents attenuated in-stent stenosis as effectively as polymer-coated sirolimus-eluting stents (SES). At SES sites, delayed endothelial healing effects were noted, whereas no such effects were observed in Pitava-NP-eluting stent sites. Pitava-NP-eluting stents attenuated in-stent stenosis as effectively as SES without the delayed endothelial healing effects of SES in a porcine coronary artery model. This nanotechnology platform could be developed into a safer and more effective device in the future.

  12. Emergency stenting for refractory acute coronary artery occlusion during coronary angioplasty

    NARCIS (Netherlands)

    P.J. de Feyter (Pim); I. DeScheerder (Ivan); M.J.B.M. van den Brand (Marcel); G-J. Laarman (GertJan); H. Suryapranata (Harry); P.W.J.C. Serruys (Patrick)

    1990-01-01

    markdownabstractAbstract Acute coronary artery occlusion occurs in 2 to 11% of the patients who undergo coronary angioplasty and is the major cause of in-hospital mortality and morbidity associated with coronary angioplasty. This procedural complication is usually caused by an occlusive

  13. Correlates and Impact of Coronary Artery Calcifications in Women Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents

    DEFF Research Database (Denmark)

    Giustino, Gennaro; Mastoris, Ioannis; Baber, Usman

    2016-01-01

    OBJECTIVES: The aim of this study was to investigate the clinical correlates and prognostic impact of coronary artery calcification (CAC) in women undergoing percutaneous coronary intervention with drug-eluting stents (DES). BACKGROUND: The clinical correlates and the prognostic significance of CAC...... in women undergoing percutaneous coronary intervention with DES remain unclear. METHODS: Patient-level data from female participants in 26 randomized trials of DES were pooled. Study population was categorized according to the presence of moderate or severe versus mild or no target lesion CAC, assessed......,371 women. Of these, 1,622 (25.5%) had moderate or severe CAC. In fully adjusted models, independent correlates of CAC were age, hypertension, hypercholesterolemia, smoking, previous coronary artery bypass graft surgery, and worse left ventricular and renal function. At 3 years, women with CAC were...

  14. Long-term outcome in patients treated with sirolimus-eluting stents in complex coronary artery lesions: 3-year results of the SCANDSTENT (Stenting Coronary Arteries in Non-Stress/Benestent Disease) trial

    DEFF Research Database (Denmark)

    Kelbaek, H.; Klovgaard, L.; Helqvist, S.;

    2008-01-01

    data of the long-term outcome of patients with complex coronary artery lesions. METHODS: We randomly assigned 322 patients with total coronary occlusions or lesions located in bifurcations, ostial, or angulated segments of the coronary arteries to have SES or BMS implanted. RESULTS: At 3 years, major...... performed between 1 and 3 years after the index treatment (p = NS). According to revised definitions, stent thrombosis occurred in 5 patients (3.1%) in the SES group and in 7 patients (4.4%) in the BMS group (p = NS); very late stent thrombosis was observed in 4 versus 1 patient. CONCLUSIONS: A continued...

  15. Carotid artery stenting in patients with coexistent carotid and coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    LUO Jian-fang; HUANG Wen-hui; WANG Shuo; DAI Cheng-bo; LI Guang; CHEN Ji-yan; ZHOU Ying-ling; WANG Li-juan

    2007-01-01

    @@ Atherosclerotic disease, as a systemic process, affects all arteries to varying degrees. In particular,coexistent carotid and coronary artery diseases are common; Management of such patients has been a point of continuing controversy.

  16. Initial impact of drug-eluting stents on coronary artery bypass graft surgery.

    Science.gov (United States)

    Liddicoat, John R; De La Torre, Ralph; Ho, Kalon K L; Nathan, Senthil; Levitsky, Sidney; Krempin, Judy; Sellke, Frank

    2006-04-01

    Drug-eluting stents (DES) reduce the incidence of restenosis after percutaneous coronary intervention and have been predicted to decrease the number of patients referred for coronary artery bypass grafting (CABG). The purpose of this study was to determine the impact of DES on the number and characteristics of patients referred for CABG. Drug-eluting stents were introduced at our hospital in April 2003 and reached maturity by June 2003. We compared our isolated CABG patients from the 12 months before the introduction of DES (year 1) with those from the 12 months after full implementation of DES (year 2). In year 1, of 4,348 cardiac catheterization patients, 2,144 (49.3%) underwent percutaneous coronary intervention, and 432 (9.9%) had CABG. In year 2, of 3,986 cardiac catheterization patients, 2,027 (50.9%) had percutaneous coronary intervention, and 337 (8.5%) had CABG, representing a 14% reduction in proportion of cardiac catheterization patients referred for CABG (p = 0.021). Among CABG patients, there was no change in age, prevalence of diabetes, or prevalence of three-vessel disease; however, patients in year 2 were more likely to have left main coronary artery disease (year 1, 36% versus year 2, 44.5%; p < 0.02) and left ventricular ejection fraction greater than 0.50 (year 1, 45% versus year 2, 52%; p < 0.02). The clinical introduction of DES was associated with a modest decrease in the percentage of cardiac catheterization patients referred for CABG. Of those referred for surgery, an increasing proportion had left main coronary artery disease and preserved left ventricular systolic function. Defining the role of DES versus CABG for coronary revascularization will require elucidation of the long-term outcomes of DES compared with CABG.

  17. Long-term effect of stenting in unprotected left main coronary artery disease in the elderly

    Institute of Scientific and Technical Information of China (English)

    Caiyi LU; Pinfa LIU; Jicai ZANG; Shiwen WANG; Lingling LIU; Qiao XUE; Xinli WU; Taohong HU; Pingshuan DONG; Zhiping WANG; Shenfang TIAN

    2005-01-01

    To evaluate the feasibility, safety and efficacy of percutaneous stent implantation for treating left main coronary artery (LMCA) stenosis. Methods Consecutive patients with unprotected left main coronary artery disease treated by stent-based percutaneous intervention (PCI) at 6 medical centers in China were enrolled. Procedural data and clinical outcomes were obtained from all patients. Results From January 2001 to December 2004, 138 patients (79 males and 59 females; mean age: 69.7±5.8 years)underwent PCI for LMCA stenosis. Bare metal stents (BMS) were implanted in 51 patients with non-bifurcational lesions and in 5 patients with bifurcational lesions from January of 2001 to June of 2003 (BMS group);. Drug eluting stents (DES) were used unselectively to cover both bifurcational and non-bifurcational lesions in 86 patients from July of 2003 to December of 2004 (DES group). Procedural success rate of the 138 cases was 98% (135/138). One patient (0.7%) with bifurcation lesion who was treated with DES died from severe heart failure 2 weeks after the procedure. During a mean follow up period of 21.3 ± 5.6 months, one patient died from renal failure, one from sudden cardiac death, 4 underwent target lesion revascularization (TLR) in the BMS group, which all occurred in patients with bifurcational lesions; whereas in the DES group no deaths occurred and only one patient with bifurcational lesion had TLR. Conclusions (1) PCI is feasible and relatively safe to treat unprotected left main coronary artery disease in elderly patients at medical centers with experienced professionals. (2) BMS and DES have similar immediate and long-term efficacy in the treatment of ostium and shaft lesions of the LMCA. (3) DES are strongly suggested in the therapy of distal bifurcation lesion of unprotected LMCA.

  18. Morphologic change in coronary artery stenosis with the Medtronic Wiktor Stent: initial results from the core laboratory for quantitative angiography

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); P.P.T. de Jaegere (Peter); M.E. Bertrand (Michel); G. Kober; J.F. Marquis; J. Piessens; R. Uebis; B. Valeix; V. Wiegand

    1991-01-01

    textabstractThe purpose of this study was to assess the early changes in stenosis geometry after implantation of the Medtronic Wiktor stent in human coronary arteries. Morphologic changes were evaluated by quantitative coronary angiography using automated edge detection. The hemodynamic significance

  19. Drug-eluting stents vs. coronary artery bypass-grafting in coronary heart disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2008-12-01

    Full Text Available Background: Coronary artery bypass graft (CABG and percutaneous revascularisations with implantation of drug-eluting stents (DES are important treatment methods in coronary heart disease (CHD. Research questions: The evaluation addresses questions on medical efficacy, health economic parameters as well as ethic, social and legal implications in the use of DES vs. CABG in CHD patients. Methods: A systematic literature search was conducted in December 2006 in the most important electronic databases beginning from 2004. Register data and controlled clinical studies were included in the evaluation. Additionally, a health economic modelling was conducted. Results: Medical evaluation: The literature search yielded 2,312 hits. 14 publications about six controlled clinical studies and five publications about two registers were included into the evaluation. Register data showed low mortality (0.2% to 0.7% and low rates of myocardial infarction (0.5% to 1.4% during hospital stay. In patients with stenosis of the left anterior descending coronary artery one study showed in several analyses a significantly higher rate of reinterventions and a significantly higher rate of repeated angina pectoris for DES up to two years after the implantation (16.8% vs. 3.6% and 35% vs. 8%. In patients with left main coronary artery stenosis two studies revealed a significantly higher survival without myocardial infarction and stroke for DES up to one year (96% vs. 79% and 95% vs. 91% and two studies a significantly higher rate of revascularisations up to two years (20% vs. 4% and 25% vs. 5% after the primary intervention. In patients with multivessel disease, one study found a significantly higher mortality and myocardial infarction rate for CABG at one year (2.7% vs. 1.0% and 4.2% vs. 1.3%. The rate of revascularisations was significantly higher in two studies up to two years after DES implantation (8.5% vs. 4.2% and 14.2% vs. 5.3%. The rate at repeated angina pectoris was

  20. A randomized, controlled, multicenter trial to evaluate the safety and efficacy of Zotarolimus- vs. Paclitaxel-eluting stents in de novo occlusive lesions in coronary arteries

    DEFF Research Database (Denmark)

    Chevalier, Bernard; Dimario, Carlo; Neumann, Franz-Josef;

    2013-01-01

    The ZOMAXX I trial tested the noninferiority of a zotarolimus-eluting coronary stent (ZoMaxx(™) ) when compared with a paclitaxel-eluting coronary stent (Taxus(™) Express(2™) ) in a randomized trial of percutaneous intervention for de novo coronary artery stenosis. Angiographic analysis at the pr...

  1. Prognosis of unprotected left main coronary artery stenting and the factors affecting the outcomes in Chinese

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background The long term prognosis of unprotected left main coronary artery (LMCA) stenting is controversial This study was conducted to evaluate the immediate and long term outcomes of LMCA stenting in Chinese patients and to determine which factors affect the outcomes. Methods From May 1997 to March 2003,224 patients in 23 hospitals underwent elective unprotected LMCA stenting with bare metal stents. Their clinical records were analysed to ascertain immediate and long term outcomes of LMCA stenting as well as factors influencing the prognosis .Results Stents were implanted into LMCA successfully in 223 cases (99.6 %). One death (0.5%) and one case of non-Q wave nonfatal myocardial infarction (MI) occurred in hospital. The mean follow-up time was (15.6±12.3) months. Cardiac death developed in 10 cases (4.5%), noncardiac death in 2 cases (0.9%), nonfatal MI in 4 cases (1.8%), target lesion revascularization (TLR) of LMCA in 26 cases (11.7%) and TLR of nonLMCA in 37 cases (16.5%). Univariate analysis showed that cardiac death correlated with left ventricular ejection fraction (LVEF < 40%), female gender and LMCA combined with multivessel disease; that major adverse cardiac events (MACE) correlated with LVEF < 40%, bifurcation lesion and incomplete revascularization. Logistic regression analysis revealed that LVEF < 40% and female gender were independent predictors of cardiac death and MACE. Follow-up angiography was performed in 102 cases (45.7%). The restenosis rate was 31.4%. Conclusions Long-term outcomes of stenting for selected patients with unprotected LMCA stenosis is acceptable. It should be performed in inoperable or low risk patients with LVEF ≥ 40% and isolated LMCA disease or LMCA combined with multivessel diseases in whom complete revascularization can be obtained.

  2. Left Main Coronary Artery Stenting to Relieve Extrinsic Compression by a Giant Pulmonary Artery Aneurysm in a Patient with Idiopathic Pulmonary Artery Hypertension.

    Science.gov (United States)

    Pan, Hung-Chih; Wang, Kuo-Yang; Liang, Kae-Woei

    2016-10-01

    Pulmonary artery aneurysm (PAA) is a rare but lethal disease. We present a female patient with idiopathic pulmonary artery hypertension (IPAH)-related PAA, who suffered from unstable angina pectoris. Multi-detector computed tomography and coronary angiogram revealed extrinsic compression of the left main coronary artery (LMCA) caused by a giant PAA with severe ostial stenosis. Intravascular ultrasound showed an oval-shaped ostium of the LMCA, indicating extrinsic compression. After successful LMCA stent implantation, chest pain was greatly relieved. This case illustrates that beyond right ventricle ischaemia and coronary atherosclerotic disease, LMCA compression by PAA should be considered in the differential diagnosis of angina in patients with IPAH related PAA. In addition, intravascular ultrasound can be used to confirm the diagnosis and guide the stent implantation safely. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  3. Improved outcomes of elderly patients treated with drug-eluting versus bare metal stents in large coronary arteries

    DEFF Research Database (Denmark)

    Kurz, David J; Bernheim, Alain M; Tüller, David

    2015-01-01

    BACKGROUND: Drug-eluting stents (DES) improve outcomes in elderly patients with small coronary artery disease compared with bare-metal stents (BMS), but randomized data in elderly patients in need of large coronary stents are not available. METHODS: Planned secondary analysis of patients ≥75 years...... recruited to the "BASKET-PROVE" trial, in which 2,314 patients undergoing percutaneous coronary intervention for large (≥3.0 mm) native vessel disease were randomized 2:1 to DES (everolimus- vs sirolimus-eluting stents 1:1) versus BMS. All patients received 12 months of dual antiplatelet therapy....... The primary end point was a composite of cardiac death or nonfatal myocardial infarction at 2 years. RESULTS: Comparison of DES versus BMS among 405 patients ≥75 years showed significantly lower rates of the primary end point for DES (5.0% vs 11.6%; hazard ration (HR) 0.64 [0.44-0.91]; P = .014). Rates...

  4. Corrosion resistance improvement for 316L stainless steel coronary artery stents by trimethylsilane plasma nanocoatings

    Science.gov (United States)

    Jones, John Eric; Chen, Meng; Yu, Qingsong

    2015-01-01

    To improve their corrosion resistance and thus long-term biocompatibility, 316L stainless steel coronary artery stents were coated with trimethylsilane (TMS) plasma coatings of 20–25 nm in thickness. Both direct current (DC) and radio-frequency (RF) glow discharges were utilized for TMS plasma coatings and additional NH3/O2 plasma treatment to tailor the surface properties. X-ray photoelectron spectroscopy (XPS) was used to characterize the coating surface chemistry. It was found that both DC and RF TMS plasma coatings had Si- and C-rich composition, and the O-and N-contents on the surfaces were substantially increased after NH3/O2 plasma treatment. Surface contact angle measurements showed that DC TMS plasma nanocoating with NH3/O2 plasma treatment generated very hydrophilic surface. The corrosion resistance of TMS plasma coated stents was evaluated through potentiodynamic polarization and electro-chemical impedance spectroscopy (EIS) techniques. The potentiodynamic polarization demonstrated that the TMS plasma coated stents imparted higher corrosion potential and pitting potential, as well as lower corrosion current densities as compared with uncoated controls. The surface morphology of stents before and after potentiodynamic polarization testing was analyzed with scanning electron microscopy, which indicated less corrosion on coated stents than uncoated controls. It was also noted that, from EIS data, the hydrophobic TMS plasma nanocoatings showed stable impedance modulus at 0.1 Hz after 21 day immersion in an electrolyte solution. These results suggest improved corrosion resistance of the 316L stainless steel stents by TMS plasma nanocoatings and great promise in reducing and blocking metallic ions releasing into the bloodstream. PMID:24500866

  5. Corrosion resistance improvement for 316L stainless steel coronary artery stents by trimethylsilane plasma nanocoatings.

    Science.gov (United States)

    Eric Jones, John; Chen, Meng; Yu, Qingsong

    2014-10-01

    To improve their corrosion resistance and thus long-term biocompatibility, 316L stainless steel coronary artery stents were coated with trimethylsilane (TMS) plasma coatings of 20-25 nm in thickness. Both direct current (DC) and radio-frequency (RF) glow discharges were utilized for TMS plasma coatings and additional NH₃/O₂ plasma treatment to tailor the surface properties. X-ray photoelectron spectroscopy (XPS) was used to characterize the coating surface chemistry. It was found that both DC and RF TMS plasma coatings had Si- and C-rich composition, and the O- and N-contents on the surfaces were substantially increased after NH₃/O₂ plasma treatment. Surface contact angle measurements showed that DC TMS plasma nanocoating with NH₃/O₂ plasma treatment generated very hydrophilic surface. The corrosion resistance of TMS plasma coated stents was evaluated through potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques. The potentiodynamic polarization demonstrated that the TMS plasma coated stents imparted higher corrosion potential and pitting potential, as well as lower corrosion current densities as compared with uncoated controls. The surface morphology of stents before and after potentiodynamic polarization testing was analyzed with scanning electron microscopy, which indicated less corrosion on coated stents than uncoated controls. It was also noted that, from EIS data, the hydrophobic TMS plasma nanocoatings showed stable impedance modulus at 0.1 Hz after 21 day immersion in an electrolyte solution. These results suggest improved corrosion resistance of the 316L stainless steel stents by TMS plasma nanocoatings and great promise in reducing and blocking metallic ions releasing into the bloodstream. © 2014 Wiley Periodicals, Inc.

  6. Preparation and surface characterization of HMDI-activated 316L stainless steel for coronary artery stents.

    Science.gov (United States)

    Chuang, T-W; Chen, M-H; Lin, F-H

    2008-06-01

    Poor compatibility between blood and metallic coronary artery stents is one reason for arterial restenosis. Immobilization of anticoagulant agents on the stent's surface is feasible for improving compatibility. We examined possible surface-coupling agents for anticoagulant agent immobilization. Hexamethylene diisocyanate (HMDI) and 3-aminopropyl-triethoxysilane (APTS) were examined as surface-coupling agents to activate 316L stainless steel (e.g., stent material). The activated surface was characterized using Fourier transformation infrared spectroscopy (FTIR), atomic force microscope (AFM), surface plasmon resonance (SPR), and trinitrobenzene sulfonic acid (TNBS) assay. In FTIR analysis, HMDI and APTS were both covalently linked to 316L stainless steel. In AFM analysis, it was found that the HMDI-activated surface was smoother than the APTS-activated one. In SPR test, the shift of SPR angle for the APTS-activated surface was much higher than that for the HMDI-activated surface after being challenged with acidic solution. TNBS assay was used to determine the amount of immobilized primary amine groups. The HMDI-activated surface was found to consist of about 1.32 micromol/cm(2) amine group, whereas the APTS-activated surface consisted of only 0.89 micromol/cm(2) amine group. We conclude that the HMDI-activated surface has more desirable surface characteristics than the APTS-activated surface has, such as chemical stability and the amount of active amine groups.

  7. Rescue coronary stenting in acute myocardial infarction

    Science.gov (United States)

    Barbieri, Enrico; Meneghetti, Paolo; Molinari, Gionata; Zardini, Piero

    1996-01-01

    Failed rescue coronary angioplasty is a high risk situation because of high mortality. Coronary stent has given us the chance of improving and maintaining the patency of the artery. We report our preliminary experience of rescue stenting after unsuccessful coronary angioplasty.

  8. In-Vitro Evaluation of Coronary Stents and 64-Detector-Row Computed Tomography Using a Newly Developed Model of Coronary Artery Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, T.; Scheuermann, T.; Ulzheimer, S.; Mohrs, O.K.; Kuehling, M.; Albrecht, P.E.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A. (Cardiovascular Center Bethanien (CCB), Frankfurt (DE))

    2008-02-15

    Background: Stent implantation is the predominant therapy for non-surgical myocardial revascularization in patients with coronary artery disease. However, despite substantial advances in multidetector computed tomography (MDCT) coronary imaging, a reliable detection of coronary in-stent restenosis is currently not possible. Purpose: To examine the ability of 64-detector-row CT to detect and to grade in-stent stenosis in coronary stents using a newly developed ex-vivo vessel phantom with a realistic CT density pattern, artificial stenosis, and a thorax phantom. Material and Methods: Four different stents (Liberte and Lunar ROX, Boston Scientific; Driver, Medtronic; Multi-Link Vision, Guidant) were examined. The stents were placed on a polymer tube with a diameter of 2.5, 3.0, 3.5, or 4.0 mm. Different degrees of stenosis (0%, 30%, 50%, 70-80%) were created inside the tube. For quantitative analysis, attenuation values were measured in the non-stenotic vessel outside the stent, in the non-stenotic vessel inside the stent, and in the stenotic area inside the stent. The grade of stenosis was visually assessed by two observers. Results: All stents led to artificial reduction of attenuation, the least degree of which was found in the Liberte stent (11.3+-10.2 HU) and the Multi-Link Vision stent (17.6+-17.9 HU; P 0.25). Overall, the non-stenotic vessel was correctly diagnosed in 55.5%, the low-grade stenosis in 58.3%, the intermediate stenosis in 63.8%, and the high-grade stenosis in 80.5%. In the 3.0-, 3.5-, and 4.0-mm vessels, in none of the cases was a non-stenotic or low-grade stenotic vessel misdiagnosed as intermediate or high-grade stenosis. The average deviation from the real grade of stenosis was 0.40 for the Liberte stent, 0.46 for the Lunar ROX stent, 0.45 for the Driver stent, and 0.58 for the Multi-Link Vision stent. Conclusion: Our ex-vivo data show that non-stenotic stents and low-grade in-stent stenosis can be reliably differentiated from intermediate and

  9. ISR II study: a long-term evaluation of sirolimus-eluting stent in the treatment of patients with in-stent restenotic native coronary artery lesions.

    Science.gov (United States)

    Commeau, Philippe; Barragan, Paul T; Roquebert, Pierre O; Siméoni, Jean B

    2005-10-01

    The aim of this pilot study was to determine the safety and long-term efficacy of treating intrastent restenosis (ISR) with the slow-release sirolimus-eluting stent Bx Velocity (Cypher stent) without intravascular ultrasound (IVUS) guidance. Of patients who received a bare metal stent implantation and presented an ISR, 30-80% of the patients will develop a second restenosis within the stent, at the stent edges or both. To date, intravascular brachytherapy using beta- and gamma-radiation has been the only effective treatment for ISR. Twenty-three patients with ISR and evidence of ischemia were treated with Cypher stent. Clinical information was collected 1, 8, 12, and 24 months after stent implantation. During the first 8 months of the study, in-stent lumen diameter remained essentially unchanged from postprocedure in 80% of the case. The target lesion repeat revascularization (TLR) was 17%, of which 50% were oculostenotic reflexes. Only one patient presented a restenosis greater than 70%. During the 2-year study period, the TLR rate was 17%; the major adverse coronary event rate was 26%, and the non-Q-wave myocardial infarction (MI) rate was 9%. There were no reports of death, coronary artery bypass grafting, or Q-wave MI during the study. This study demonstrates the feasibility of using sirolimus-eluting stents without IVUS guidance for the treatment of ISR, providing long-term stability of immediate results.

  10. One-year outcomes of coronary artery bypass graft surgery versus percutaneous coronary intervention with multiple stenting for multisystem disease: a meta-analysis of individual patient data from randomized clinical trials.

    Science.gov (United States)

    Mercado, Nestor; Wijns, William; Serruys, Patrick W; Sigwart, Ulrich; Flather, Marcus D; Stables, Rodney H; O'Neill, William W; Rodriguez, Alfredo; Lemos, Pedro A; Hueb, Whady A; Gersh, Bernard J; Booth, Jean; Boersma, Eric

    2005-08-01

    We aimed to provide a quantitative analysis of the 1-year clinical outcomes of patients with multisystem coronary artery disease who were included in recent randomized trials of percutaneous coronary intervention with multiple stenting versus coronary artery bypass graft surgery. An individual patient database was composed of 4 trials (Arterial Revascularization Therapies Study, Stent or Surgery Trial, Argentine Randomized Trial of Percutaneous Transluminal Coronary Angioplasty Versus Coronary Artery Bypass Surgery in Multivessel Disease 2, and Medicine, Angioplasty, or Surgery Study 2) that compared percutaneous coronary intervention with multiple stenting (N = 1518) versus coronary artery bypass graft surgery (N = 1533). The primary clinical end point of this study was the combined incidence of death, myocardial infarction, and stroke at 1 year after randomization. Secondary combined end points included the incidence of repeat revascularization at 1 year. All analyses were based on the intention-to-treat principle. After 1 year of follow-up, 8.7% of patients randomized to percutaneous coronary intervention with multiple stenting versus 9.1% of patients randomized to coronary artery bypass graft surgery reached the primary clinical end point (hazard ratio 0.95 and 95% confidence interval 0.74-1.2). Repeat revascularization procedures occurred more frequently in patients allocated to percutaneous coronary intervention with multiple stenting compared with coronary artery bypass graft surgery (18% vs 4.4%; hazard ratio 4.4 and 95% confidence interval 3.3-5.9). The percentage of patients who were free from angina was slightly lower after percutaneous coronary intervention with multiple stenting than after coronary artery bypass graft surgery (77% vs 82%; P = .002). One year after the initial procedure, percutaneous coronary intervention with multiple stenting and coronary artery bypass graft surgery provided a similar degree of protection against death, myocardial

  11. Percutaneous transluminal angioplasty and stenting of the vertebral artery ostium with balloon-mounted bare coronary stents

    Directory of Open Access Journals (Sweden)

    Javad Kojuri

    2011-01-01

    Full Text Available Background : Vertebral artery ostial stenosis (VAOS is one of the most frequent causes of posterior circulation stroke. Percutaneous angioplasty and stenting (PTAS is one of the treatment modalities. Patients and Methods : This is a longitudinal observational study from September 2006 to February 2009, conducted at hospitals affiliated with the Shiraz University of Medical Sciences, Shiraz, southern Iran. The patient cohort included patients with posterior circulation stroke or transient ischemic attack (TIA and more than 70% VAOS, and patients with asymptomatic VAOS of more than 70% and aplasia or total occlusion of the contralateral VA or subclavian artery. All the patients underwent PTAS with balloon-mounted bare coronary stents. Technical success, procedural complications, composite outcomes of death, stroke or TIA in the vertebrobasilar territory during the first 30 days, stroke or TIA in the vertebrobasilar territory, and restenosis during follow-up, were assessed. Results : During the study period, 81 patients (mean age 68 + 8.9 years, 63 (78% males, 71 symptomatic and 18 asymptomatic underwent the procedure. Technical success was achieved in 88 (99% patients. Procedure-related complications, other than puncture site complications, were seen in two patients (2.2%. The composite outcome of death, stroke or TIA in the vertebrobasilar territory during the first 30 days was 1%. None of the patients had clinical recurrence or restenosis during the follow-up (mean follow-up 14 months. Conclusion : Percutaneous transluminal angioplasty and stenting of the proximal VA was feasible and safe. The risk of restenosis should be analyzed in long-term studies with angiographic follow-up.

  12. Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries.

    Science.gov (United States)

    Kefer, Joelle M; Coche, Emmanuel; Vanoverschelde, Jean-Louis J; Gerber, Bernhard L

    2007-01-01

    The purpose of this study was to assess the diagnostic accuracy of 16-slice multidetector-row computed tomography (MDCT) for detecting in-stent restenosis. Fifty patients with 69 previously implanted coronary stents underwent 16-slice MDCT before quantitative coronary angiography (QCA). Diagnostic accuracy of MDCT for detection of in-stent restenosis defined as >50% lumen diameter stenosis (DS) in stented and nonstented coronary segments >1.5-mm diameter was computed using QCA as reference. According to QCA, 18/69 (25%) stented segments had restenosis. In addition, 33/518 (6.4%) nonstented segments had >50% DS. In-stent restenosis was correctly identified on MDCT images in 12/18 stents, and absence of restenosis was correctly identified in 50/51 stents. Stenosis in native coronary arteries was correctly identified in 22/33 segments and correctly excluded in 482/485 segments. Thus, sensitivity (67% vs 67% p=1.0), specificity (98% vs 99%, p=0.96) and overall diagnostic accuracy (90% vs 97%, p=0.68) was similarly high for detecting in-stent restenosis as for detecting stenosis in nonstented coronary segments. MDCT has similarly high diagnostic accuracy for detecting in-stent restenosis as for detecting coronary artery disease in nonstented segments. This suggests that MDCT could be clinically useful for identification of restenosis in patients after coronary stenting.

  13. Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kefer, Joelle M.; Vanoverschelde, Jean-Louis J.; Gerber, Bernhard L. [Cliniques Universitaires St. Luc UCL, Department of Cardiology, Brussels (Belgium); Coche, Emmanuel [Cliniques Universitaires St. Luc UCL, Department of Radiology, Brussels (Belgium)

    2007-01-15

    The purpose of this study was to assess the diagnostic accuracy of 16-slice multidetector-row computed tomography (MDCT) for detecting in-stent restenosis. Fifty patients with 69 previously implanted coronary stents underwent 16-slice MDCT before quantitative coronary angiography (QCA). Diagnostic accuracy of MDCT for detection of in-stent restenosis defined as >50% lumen diameter stenosis (DS) in stented and nonstented coronary segments >1.5-mm diameter was computed using QCA as reference. According to QCA, 18/69 (25%) stented segments had restenosis. In addition, 33/518 (6.4%) nonstented segments had >50% DS. In-stent restenosis was correctly identified on MDCT images in 12/18 stents, and absence of restenosis was correctly identified in 50/51 stents. Stenosis in native coronary arteries was correctly identified in 22/33 segments and correctly excluded in 482/485 segments. Thus, sensitivity (67% vs 67% p=1.0), specificity (98% vs 99%, p=0.96) and overall diagnostic accuracy (90% vs 97%, p=0.68) was similarly high for detecting in-stent restenosis as for detecting stenosis in nonstented coronary segments. MDCT has similarly high diagnostic accuracy for detecting in-stent restenosis as for detecting coronary artery disease in nonstented segments. This suggests that MDCT could be clinically useful for identification of restenosis in patients after coronary stenting. (orig.)

  14. One-year clinical outcomes of Chinese sirolimus-eluting stent in the treatment of unselected patients with coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ The application of drug-eluting stent (DES), either sirolimus-eluting stent (Cypher, Cordis, USA) or paclitaxel-eluting stent (Taxus, Boston Scientific, USA), in treatment of patients with coronary artery disease (CAD) has achieved great success.1-4 The high cost of imported DES (either Cypher or Taxus) gave the birth to a China-made, polymer-based, sirolimus-eluting stent (Firebird, Microport Company, China). In March 2003, China Food and Drug Administration approved the clinical use of Firebird stent. However, the safety and efficacy of Firebird stent in comparison with Cypher and Taxus stents are still underestimated.

  15. Successful stenting of catheter-induced unprotected left main coronary artery dissection

    NARCIS (Netherlands)

    G. Ertaş; E. Ural (E.); W.J. van der Giessen (Wim)

    2012-01-01

    textabstractCatheter-induced left main coronary artery (LMCA) dissection is a dramatic, although uncommon complication of diagnostic coronary angiography and requires prompt treatment. We describe a case of iatrogenic occlusive dissection of the LMCA during coronary angiography, treated by

  16. Prevention of restenosis in coronary arteries: ionic radiation, non-ionic radiation and drug eluting stents

    NARCIS (Netherlands)

    E.S. Regar (Eveline)

    2002-01-01

    textabstractOver the last decade, coronary stents have revolutionized the field of interventional cardiology. Stent implantation has become the new standard angioplasty procedure1-3. This popularity has grown because of 2 main reasons: first, the unique capability to master a major complication of b

  17. Six-month results of a biodegradable polymer and rapamycin-coating stent for coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    Yuxiao ZHANG; Caiyi LU; Qiao XUE; Peng LIU; Wei YAN; Rui CHEN

    2006-01-01

    Objective To assess the safety and efficacy of a novel biodegradable polymer and rapamycin-coating stent, the EXCEL stent, in the treatment of coronary artery disease (CAD), as compared with the CypherTM stent. Methods In this prospective, non-randomized study, 60 consecutive patients with symptomatic CAD received either an EXCEL stent (n=32), or a CypherTM stent(n=28),according to their respective treatment intention. Follow-up angiography was performed at a mean of 180±40 days. The primary endpoint of the study was the occurrence of a major adverse cardiac event (MACE), including death, myocardial infarction, or target-vessel revascularization during the 6 months after stenting. The secondary end points included the in-stent late luminal loss (LLL), percentage of in-stent stenosis of the luminal diameter, and the rate of restenosis (luminal narrowing of 50 percent or more) at 6 months. Results There were no significant differences between the two groups in baseline characteristics, including the distribution of target vessel and lesion types. During the follow up period of 6 months, there were no occurrences of MACE in either group. Twenty-seven patients(84%) in the EXCEL group and 10 (36 %) in the CypherTM group underwent quantitative coronary angiography at 6 months. For these patients, no restenosis occurred, and there were no differences in the in-stent stenosis of the luminal diameter (5.98±5.52% vs 5.21 ±6.3%,P>0.05) and the LLL (-0.02±0.09 mm vs -0.01±0.07 mm, P>0.05). Conclusions Compared with the CypherTM stent, the EXCEL Stent with biodegradable polymer and rapamycin-coating showed similar efficacy in the prevention of neointimal proliferation, restenosis, and associated clinical events in CAD patients.

  18. Impact of coexisting coronary artery disease on the occurrence of cerebral ischemic lesions after carotid stenting.

    Directory of Open Access Journals (Sweden)

    Kuo-Lun Huang

    Full Text Available BACKGROUND: Coronary artery disease (CAD may coexist with extracranial carotid artery stenosis (ECAS, but the influence of CAD on procedure-related complications after carotid artery stenting (CAS has not been well investigated. The study aimed to determine the impact of CAD on the occurrence of peri-CAS cerebral ischemic lesions on diffusion-weighted imaging (DWI scanning. METHODS: Coronary angiography was performed within six months before CAS. DWI scanning was repetitively done within 1 week before and after CAS. Clinical outcome measures were stroke, angina, myocardial infarction and death within 30 days. RESULTS: Among 126 patients (69.5±9.0 years recruited for unilateral protected CAS, 33 (26% patients had peri-CAS DWI-positive lesions. CAD was noted in 79% (26 in 33 and 48% (45 in 93 of patients with and without peri-CAS DWI-positive lesions (OR, 4.0; 95% CI, 1.6-10.0; P = .0018, and the number of concomitant CAD on coronary angiography was positively correlated with the risk for peri-CAS DWI-positive lesions (P = .0032. In patients with no CAD (n = 55, asymptomatic CAD (n = 41 and symptomatic CAD (n = 30, the occurrence rates of peri-CAS DWI-positive lesions were 13%, 41% and 30% (P = .0048, and the peri-CAS stroke rates were 2%, 7% and 0% (P = .2120. CONCLUSIONS: The severity of morphological CAD and the presence of either symptomatic or asymptomatic CAD are associated with the occurrence of peri-CAS cerebral ischemic lesions.

  19. Successful treatment of cardiogenic shock by stenting of the left main coronary artery in acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Knežević Božidarka

    2008-01-01

    Full Text Available Introduction. Patients with non-ST elevation acute coronary syndromes (NSTE-ACS are sometimes severely hemodynamicly compromised. Urgent coronary angiography should be performed in these patients in percutaneous coronary intervention (PCI centers according to the ESC NSTE-ACS guidelines to determine suitabilty for percutaneous or surgical revascularization. Case report. We reported a 62-year-old male with chest pain admitted to the Coronary Care Unit. ST segment depression of 2 mm in leads I, L and V4-6 was revealed at electrocardiogram. After following 6 hours the patient had chest pain and signs of cardiogenic shock despite of the therapy. Chest x-ray showed pulmonary edema. Echocardiographic examination showed dyskinetic medium and apical segments of septum. The patient underwent coronary angiography immediately which revealed 75% stenosis of the left main coronary artery with thrombus. The use of a GPIIb/III inhibitor-tirofiban and stent implantation resulted in TIMI III flow. After that the patient had no chest pain and acute heart failure subsided in the following days Echocardiography done at the fourth day from PCI showed only hypokinesis medium and apical segment of septum. The patient was discharged at day 11 from admission in a stable condition. Conclusion. Stenting of left main coronary artery stenosis in patients with cardiogenic shock and non- ST segment elevation acute coronary syndromes may be a life saving procedure.

  20. Triple antithrombotic therapy in patients with atrial fibrillation undergoing coronary artery stenting: hovering among bleeding risk, thromboembolic events, and stent thrombosis

    Directory of Open Access Journals (Sweden)

    Menozzi Mila

    2012-10-01

    Full Text Available Abstract Dual antiplatelet treatment with aspirin and clopidogrel is the antithrombotic treatment recommended after an acute coronary syndrome and/or coronary artery stenting. The evidence for optimal antiplatelet therapy for patients, in whom long-term treatment oral anticoagulation is mandatory, is however scarce. To evaluate the safety and efficacy of the various antithrombotic strategies adopted in this population, we reviewed the available evidence on the management of patients receiving oral anticoagulation, such as a vitamin-k-antagonists, referred for coronary artery stenting. Atrial fibrillation is the most frequent indication for oral anticoagulation. The need of starting antiplatelet therapy in this clinical scenario raises concerns about the combination to choose: triple therapy with warfarin, aspirin, and a thienopyridine being the most frequent and advised. The safety of this regimen appeared suboptimal because of an increased risk in hemorrhagic complications. On the other hand, the combination of oral anticoagulation and an antiplatelet agent is suboptimal in preventing thromboembolic events and stent thrombosis; dual antiplatelet therapy may be considered only when a high hemorrhagic risk and low thromboembolic risk are perceived. Indeed, the need for prolonged multiple-drug antithrombotic therapy increases the bleeding risks when drug eluting stents are used. Since current evidence derives mainly from small, single-center and retrospective studies, large-scale prospective multicenter studies are urgently needed.

  1. Five-Year Long-Term Clinical Follow-Up of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de novo Coronary Artery Lesions: The SPIRIT FIRST Trial

    NARCIS (Netherlands)

    M. Wiemer; P.W. Serruys; K. Miquel-Hebert; F.J. Neumann; J.J. Piek; E. Grube; J. Haase; L. Thuesen; C. Hamm

    2010-01-01

    Background: Drug-eluting stents have shown to be superior over bare metal stents in clinical and angiographic outcomes after percutaneous treatment of coronary artery stenosis. However, long-term follow-up data are scarce and only available for sirolimus- and paclitaxel-eluting stents. Aim: To asses

  2. Long-term safety and efficacy of percutaneous coronary intervention with stenting and coronary artery bypass surgery for multivessel coronary artery disease: A meta-analysis with 5-year patient-level data from the ARTS, ERACI-II, MASS-II, and SoS trials

    NARCIS (Netherlands)

    J. Daemen (Joost); H. Boersma (Eric); M. Flather (Marcus); J. Booth (Jean); R.H. Stables (Rodney); A. Rodriguez (Alfredo Chapin); G.A. Rodriguez-Granillo (Gaston); W.A. Hueb (Whady Armindo); P.A. Lemos Neto (Pedro); P.W.J.C. Serruys (Patrick)

    2008-01-01

    textabstractBackground - Randomized trials that studied clinical outcomes after percutaneous coronary intervention (PCI) with bare metal stenting versus coronary artery bypass grafting (CABG) are underpowered to properly assess safety end points like death, stroke, and myocardial infarction. Pooling

  3. Drug-eluting stents:is it the beginning of the end for coronary artery bypass surgery?

    Institute of Scientific and Technical Information of China (English)

    Shahzad G Raja

    2004-01-01

    @@ Myocardial revascularization therapy of coronary artery disease is one of the most important medical advances of the past 50 years.1 Coronary revascularization by either bypass surgery or coronary angioplasty relieves angina and may improve the prognosis in patients with coronary artery disease.2,3 Randomized comparisons reveal no difference in survival free from myocardial infarction (MI) between surgery and balloon angioplasty.4,5 Stenting significantly improved the long-term outcome, while surgery is still associated with fewer reinterventions during follow-up.6-10 However, subsequent improvements in both percutaneous and surgical techniques may now limit the validity of any conclusions that have been drawn from the earlier studies. In fact, the lines of demarcation for patients suited for bypass or angioplasty are becoming blurry with each passing day.

  4. ANGIOPLASTIA PERCUTÁNEA CON STENT EN EL TRONCO PRINCIPAL DE LA ARTERIA CORONARIA IZQUIERDA / Percutaneous angioplasty with stent in the left main coronary artery

    Directory of Open Access Journals (Sweden)

    Javier Almeida Gómez

    2012-10-01

    Full Text Available ResumenIntroducción y objetivos: La afectación significativa del tronco común izquierdo, es la más letal de las presentaciones de la enfermedad arterial coronaria. El tratamiento de elección, es la cirugía de derivación aorto-coronaria. En varios estudios multicéntricos, se sugiere la posibilidad de tratar la enfermedad de tronco mediante el intervencionismo coronario percutáneo con implantación de prótesis endoluminal o stent. El objetivo de esta investigación fue caracterizar la angioplastia percutánea con stent en el tronco principal de la arteria coronaria izquierda. Método: Se realizó un estudio observacional, descriptivo y transversal en 21 pacientes con angioplastia percutánea con stent en el tronco principal de la arteria coronaria izquierda, realizadas en el laboratorio de Hemodinámica y Cardiología Intervencionista del Hospital "Hermanos Ameijeiras", entre enero 2010 y julio 2011. Resultados: No existió diferencia significativa en el sexo. Predominó el grupo de edad entre 50-64 años (47,6 % y el color de la piel blanca (76,19 %. El factor de riesgo cardiovascular más encontrado fue la HTA (85,71 %, seguido de dislipidemia (47,61 %. El diagnóstico más observado fue la angina de esfuerzo estable, 14 casos (66,66 %. La lesión en el cuerpo del tronco (12 pacientes, 57,1 %, fue la más encontrada, seguida de la ostial (8 casos. El tipo de stent más utilizado fue el liberador de fármacos (61,9 %, y solamente 4 pacientes presentaban troncos protegidos quirúrgicamente. Conclusiones: La mayor cantidad de casos fueron electivos, con predominio de los troncos no protegidos. El factor de riesgo coronario más encontrado fue la HTA. Se encontró asociación significativa entre la diabetes mellitus y la localización ostial de la lesión tratada. / AbstractIntroduction and Objectives: Significant impairment of the left main coronary artery is the most lethal presentation of coronary artery disease. The treatment of choice

  5. Dual anterior descending coronary artery associated with coronary artery disease

    Directory of Open Access Journals (Sweden)

    Siqueira Luciane da L. V.

    2003-01-01

    Full Text Available The patient is a male with risk factors for coronary artery disease, who was referred for cardiac catheterization after acute myocardial infarction in the inferior wall. The patient underwent transluminal coronary angioplasty in the right coronary artery with successful stent implantation.

  6. Comparison of in-hospital and long-term outcomes between a Cypher stent and a Taxus stent in Chinese diabetic patients with coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    YANG Yue-jin; WU Yong-jian; LIU Hai-bo; YOU Shi-jie; LI Jian-jun; DAI Jun; GAO Run-lin; XU Bo; KANG Sheng; PEI Wei-dong; CHEN Ji-lin; QIAO Shu-bin; QIN Xue-wen; YAO Min; CHEN Jue

    2007-01-01

    Background The sirolimus and paclitaxel distribution patterns and tissue residence time may be modified in atherosclerotic lesions for patients with diabetes, and the biological mechanisms of action for these agents differ significantly. Previous clinical trials have yielded discrepant results of major adverse cardiac events and restenosis between a sirolimus-eluting stent and a paclitaxel-eluting stent in coronary artery disease. Therefore, this study was conduced to compare in-hospital and long-term clinical outcomes between patients receiving sirolimus-eluting stent(Cypher or Cypher Select stent) and paclitaxel-eluting stent (Taxus Express stent) after percutaneous intervention (PCI)in Chinese patients with diabetes.Methods One hundred and sixty-four consecutive diabetic patients underwent PCI in Fuwai Hospital from April 2004 to December 2004. Of them, 101 patients received Cypher or Cypher Select stents (Cypher group, 145 stents) and 63patients received Taxus Express stents (Taxus group, 129 stents). Repeat coronary angiography was performed at6-month and clinical outcomes were evaluated at 1- and 3-year follow-up. Stent thrombosis was classified according to Academic Research Consortium (ARC).Results The two groups did not differ significantly with respect to cardiac death, recurrent myocardial infarction (re-MI),target vessel revascularization (TVR) and occurrence of major adverse cardiac events (MACE). And the MACE-free cumulative survival at 1- and 3-year follow-up and early, late and very late thrombosis rates were also similar in the two groups (all P>0.05). There was a trend favoring PES over SES with regard to reducing cardiac death (0 vs 2.0%,P=0.524), re-MI (0 vs 2.0%, P=0.524), the composite of the cardiac death and re-MI (0 vs 4.0%, P=0.299) and very late thrombosis (0 vs 3.0%, P=0.295) between 1-year and 3-year follow-up.Conclusion The study indicates that PCI with either Cypher or Taxus stents is associated with similar efficacy and safety in

  7. Impact of the introduction of drug eluting stents on clinical outcomes in patients undergoing percutaneous and surgical coronary artery revascularisation procedures in Western Australia

    OpenAIRE

    Sanfilippo, Frank M; Rankin, Jamie M.; Hobbs, Michael ST; Nguyen, Michael; Knuiman, Matthew W; Berg, Patricia; Whitford, Eric G; Hendriks, Randall; Hockings, Bernard E; Muhlmann, Michael; Newman, Mark; Larbalestier, Robert; Gilfillan, Ian; Briffa, Thomas G

    2013-01-01

    Background Increasing rates of percutaneous coronary intervention (PCI) and decreasing rates of coronary artery bypass graft (CABG) surgery followed the introduction of drug eluting stents in Western Australia in 2002. We assessed the impact of these changes on one-year outcomes for the total population of patients undergoing coronary artery revascularisation procedures (CARP) in Western Australia between 2000-2004. Methods Clinical and linked administrative data (inpatient admissions and dea...

  8. Very late coronary aneurysm formation with subsequent stent thrombosis secondary to drug-eluting stent

    Institute of Scientific and Technical Information of China (English)

    Ibrahim Akin,; Stephan Kische; Tim C Rehders; Henrik Schneider; G(o)kmen R Turan; Tilo Kleinfeldt; Jasmin Ortak; Christoph A. Nienaber; Hüseyin Ince

    2011-01-01

    Drug-eluting stents have changed the practice in interventional cardiology.With the widespread use of these stents important safety concerns regarding stent thrombosis and formation of coronary artery aneurysm have been expressed.While the majority of attention was focused on stent thrombosis,the formation of coronary aneurysm was only described in anecdotal reports.We report on a patient who suffered from very late stent thrombosis in association with coronary artery aneurysm formation secondary to drug-eluting stent but not to bare-metal stent.

  9. Carotid artery stenting in patients with acute coronary syndrome: a possible primary therapy for symptomatic carotid stenosis.

    Science.gov (United States)

    Casana, Renato; Halliday, Alison; Bianchi, Paolo; Fresa, Emanuele; Silani, Vincenzo; Parati, Gianfranco; Blengino, Simonetta; Cireni, Lea; Adobbati, Laura; Calvillo, Laura; Tolva, Valerio S

    2013-08-01

    To report the results of carotid artery stenting (CAS) in symptomatic patients (stroke/transient ischemic attack) after recent percutaneous transluminal coronary angioplasty (PTCA) for acute coronary syndrome (ACS). Between January 2009 and July 2011, 28 consecutive patients (18 women; mean age 66 years, range 42-82) underwent protected CAS for symptomatic carotid stenosis following recent PTCA that included bare or drug-eluting stents requiring uninterrupted dual antiplatelet therapy. Primary technical success, neurological complications, major adverse cardiovascular events, and death were evaluated at 30 days and over midterm follow-up. Technical success was 96%; 1 patient suffered a nonfatal major stroke (3.5% 30-day stroke rate) during the procedure. During a median 21.6-month follow-up, 4 (14%) patients died of myocardial infarction (all diabetic smokers with ejection fractions 34 kg/m(2). This preliminary experience demonstrated that CAS is a reasonable, safe, and effective treatment for patients with symptomatic carotid artery stenosis who were recently treated with coronary stents requiring uninterrupted dual antiplatelet therapy.

  10. Multiple coronary thrombosis and stent implantation to the subtotally occluded right renal artery in a patient with essential thrombocytosis: a case report with review.

    Science.gov (United States)

    Ozben, Beste; Ekmekci, Ahmet; Bugra, Zehra; Umman, Sabahattin; Meric, Mehmet

    2006-08-01

    Essential thrombocytosis is a myeloproliferative disorder of unknown etiology manifested clinically by the overproduction of platelets in the absence of a definable cause. Platelet dysfunction in essential thrombocytosis results in both hemorrhage and thrombosis. It is one of the rare causes of ischemic cardiovascular events. Fewer than 20 cases of essential thrombocytosis with involvement of coronary arteries leading to acute coronary syndromes or myocardial infarction have been reported. We report a case of multiple coronary thrombosis involving the left anterior descending artery and circumflex artery and stent implantation to the subtotally stenotic right renal artery in a women with unstable angina pectoris, essential thrombocytosis and previous history of renal artery trombosis.

  11. Clinical Outcomes After Drug-Eluting Stents Versus Coronary Artery Bypass Surgery in High Surgical Risk Patients With Left Main or Three-Vessel Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Tonga Nfor

    2015-08-01

    Full Text Available Purpose: Previous studies comparing percutaneous coronary intervention (PCI with coronary artery bypass graft surgery (CABG in patients with unprotected left main or three-vessel coronary artery disease (LM-3VD have excluded patients at high surgical risk. We compared clinical outcomes after PCI with drug-eluting stents to CABG in high surgical risk patients with LM-3VD. Methods: Patients with symptomatic LM-3VD who had Society of Thoracic Surgeons (STS-predicted operative mortality > 5% and were undergoing either PCI with drug-eluting stents or CABG at a tertiary care center from January 2009 to December 2010 were enrolled in this nonrandomized prospective study. Results: Mean STS score was 14.5 ± 5.8% for PCI (n=83 vs. 13.6 ± 7.1% for CABG (n=187 (P=0.31. After mean follow-up of 37 months, incidence of the composite primary endpoint (death, myocardial infarction or stroke was 42.2% for PCI and 39.6% for CABG (P=0.69, hazard ratio 1.3, 95% confidence interval 0.5-2.8. There were no differences in the individual components of the primary endpoint between PCI and CABG. Repeat revascularization was 30.1% for PCI vs. 9.6% for CABG (P=0.001. Major adverse cardiac and cerebrovascular event rates were similar between PCI and CABG, 50.6% vs. 42.2%, respectively (P=0.23. Patients in the PCI group were less likely than those in the CABG group to be discharged to a nursing home (12.1% vs. 47.1%, P 5%.

  12. [Absorbable coronary stents. New promising technology].

    Science.gov (United States)

    Erbel, Raimund; Böse, Dirk; Haude, Michael; Kordish, Igor; Churzidze, Sofia; Malyar, Nasser; Konorza, Thomas; Sack, Stefan

    2007-06-01

    Coronary stent implantation started in Germany 20 years ago. In the beginning, the progress was very slow and accelerated 10 years later. Meanwhile, coronary stent implantation is a standard procedure in interventional cardiology. From the beginning of permanent stent implantation, research started to provide temporary stenting of coronary arteries, first with catheter-based systems, later with stent-alone technology. Stents were produced from polymers or metal. The first polymer stent implantation failed except the Igaki-Tamai stent in Japan. Newly developed absorbable polymer stents seem to be very promising, as intravascular ultrasound (IVUS) and optical coherence tomography have demonstrated. Temporary metal stents were developed based on iron and magnesium. Currently, the iron stent is tested in peripheral arteries. The absorbable magnesium stent (Biotronik, Berlin, Germany) was tested in peripheral arteries below the knee and meanwhile in the multicenter international PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) study. The first magnesium stent implantation was performed on July 30, 2004 after extended experimental testing in Essen. The magnesium stent behaved like a bare-metal stent with low recoil of 5-7%. The stent struts were absorbed when tested with IVUS. Stent struts were not visible by fluoroscopy or computed tomography (CT) as well as magnetic resonance imaging (MRI). That means, that the magnesium stent is invisible and therefore CT and MRI can be used for imaging of interventions. Only using micro-CT the stent struts were visible. The absorption process could be demonstrated in a patient 18 days after implantation due to suspected acute coronary syndrome, which was excluded. IVUS showed a nice open lumen. Stent struts were no longer visible, but replaced by tissue indicating the previous stent location. Coronary angiography after 4 months showed an ischemia-driven target lesion

  13. [On evaluating occupational fitness in railway workers with ventricular arrhythmias after coronary arteries stenting].

    Science.gov (United States)

    Muraseyeva, E V; Gorokhova, S G; Prigorovskaya, T S; Pfaf, V F

    2016-01-01

    The authors studied prospects of work capacity preserving after coronary stenting in IHD and cardiac arrhythmias. Examination covered 158 railway workers underwent complete endovascular revascularization of myocardium for coronary stenosis; all of them had ventricular arrhythmias before coronary surgery. Findings are that in long-term period (in 16 months in average) after coronary stenting, grade I and III ventricular extrasystoles disappeared in 77.8 and 54.5% of cases respectively, but only in 11.9% of grade IV ventricular extrasystoles cases. Ventricular extrasystoles remained unchanged in 44.3% of cases. Reliable relationships were seen between unchanged grade IV ventricular extrasystoles and body weight index (OR = 5.49, 95% CI: 0.87-34.67), general cholesterol level (OR = 1.69; 95% CI: 1.06-2.69), low density lipoproteins (OR = 1.66; 95% CI: 1.00-2.76) and left ventricular ejection function lower 45% (OR = 1.61; 95% CI: 1.14-2.27), exertion ventricular extrasystoles before myocardium revascularization (OR = 3.1; 95% CI: 1.78-5.41). That necessitates correction of the mentioned risk factors of cardiac arrhythmias for restored work capacity.

  14. Sirolimus- vs paclitaxel-eluting stents in de novo coronary artery lesions - The REALITY trial: A randomized controlled trial

    NARCIS (Netherlands)

    M-C. Morice (Marie-Claude); A. Colombo (Antonio); B. Meier (Bernard); P.W.J.C. Serruys (Patrick); C. Tamburino (Corrado); G. Guagliumi (Giulio); E. Sousa (Eduardo); H.P. Stoll

    2006-01-01

    textabstractContext: Compared with bare metal stents, sirolimus-eluting and paclitaxel-eluting stents have been shown to markedly improve angiographic and clinical outcomes after percutaneous coronary revascularization, but their performance in the treatment of de novo coronary lesions has not been

  15. The Relationship Between Lymphocyte-to-Monocyte Ratio and Bare-Metal Stent In-Stent Restenosis in Patients With Stable Coronary Artery Disease.

    Science.gov (United States)

    Murat, Sani Namik; Yarlioglues, Mikail; Celik, Ibrahim Etem; Kurtul, Alparslan; Duran, Mustafa; Kilic, Alparslan; Oksuz, Fatih

    2017-04-01

    In-stent restenosis (ISR) is a common clinical problem in patients with coronary artery disease treated with percutaneous coronary intervention. Inflammatory process plays a pivotal role in the development of ISR. Both lymphocytes and monocytes are associated with inflammatory status. Recently, it has been shown that the lymphocyte-to-monocyte ratio (LMR) is a novel inflammatory marker. We aimed to investigate the association of serum LMR levels and ISR in patients undergoing bare-metal stent (BMS) implantation. The study included 273 patients (aged 61 ± 11 years, 66.5% men) with a history of BMS implantation and a further control coronary angiography due to stable angina pectoris. Patients were divided into 2 groups: patients with and without ISR. The LMR levels were significantly lower in patients with ISR than in those without ISR (2.50 ± 0.95 vs 3.87 ± 1.51, respectively, P ISR (odds ratio [OR]: 0.310, 95% confidence interval: 0.166-0.579, P ISR in patients treated with BMS implantation.

  16. Coronary Artery Stent Evaluation Using a Vascular Model at 64-Detector Row CT: Comparison between Prospective and Retrospective ECG-Gated Axial Scans

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Shigeru; Furui, Shigeru; Kaminaga, Tatsuro; Miyazawa, Akiyoshi; Ueno, Yasunari; Konno, Kumiko [Teikyo University School of Medicine, Tokyo (Japan); Kuwahara, Sadatoshi; Mehta, Dhruv [Philips Electronics Japan, Ltd. Medical Systems, Tokyo (Japan)

    2009-06-15

    We wanted to evaluate the performance of prospective electrocardiogram (ECG)-gated axial scans for assessing coronary stents as compared with retrospective ECG-gated helical scans. As for a vascular model of the coronary artery, a tube of approximately 2.5-mm inner diameter was adopted and as for stents, three (Bx-Velocity, Express2, and Micro Driver) different kinds of stents were inserted into the tube. Both patent and stenotic models of coronary artery were made by instillating different attenuation (396 vs. 79 Hounsfield unit [HU]) of contrast medium within the tube in tube model. The models were scanned with two types of scan methods with a simulated ECG of 60 beats per minute and using display field of views (FOVs) of 9 and 18 cm. We evaluated the in-stent stenosis visually, and we measured the attenuation values and the diameter of the patent stent lumen. The visualization of the stent lumen of the vascular models was improved with using the prospective ECG-gated axial scans and a 9-cm FOV. The inner diameters of the vascular models were underestimated with mean measurement errors of -1.10 to -1.36 mm. The measurement errors were smaller with using the prospective ECG-gated axial scans (Bx-Velocity and Express2, p < 0.0001; Micro Driver, p = 0.0004) and a 9-cm FOV (all stents: p < 0.0001), as compared with the other conditions, respectively. The luminal attenuation value was overestimated in each condition. For the luminal attenuation measurement, the use of prospective ECG-gated axial scans provided less measurement error compared with the retrospective ECG-gated helical scans (all stents: p < 0.0001), and the use of a 9-cm FOV tended to decrease the measurement error. The visualization of coronary stents is improved by the use of prospective ECG-gated axial scans and using a small FOV with reduced blooming artifacts and increased spatial resolution.

  17. Coronary artery fistula

    Science.gov (United States)

    Congenital heart defect - coronary artery fistula; Birth defect heart - coronary artery fistula ... A coronary artery fistula is often congenital, meaning that it is present at birth. It generally occurs when one of the coronary arteries ...

  18. Computational replication of the patient-specific stenting procedure for coronary artery bifurcations: From OCT and CT imaging to structural and hemodynamics analyses.

    Science.gov (United States)

    Chiastra, Claudio; Wu, Wei; Dickerhoff, Benjamin; Aleiou, Ali; Dubini, Gabriele; Otake, Hiromasa; Migliavacca, Francesco; LaDisa, John F

    2016-07-26

    The optimal stenting technique for coronary artery bifurcations is still debated. With additional advances computational simulations can soon be used to compare stent designs or strategies based on verified structural and hemodynamics results in order to identify the optimal solution for each individual's anatomy. In this study, patient-specific simulations of stent deployment were performed for 2 cases to replicate the complete procedure conducted by interventional cardiologists. Subsequent computational fluid dynamics (CFD) analyses were conducted to quantify hemodynamic quantities linked to restenosis. Patient-specific pre-operative models of coronary bifurcations were reconstructed from CT angiography and optical coherence tomography (OCT). Plaque location and composition were estimated from OCT and assigned to models, and structural simulations were performed in Abaqus. Artery geometries after virtual stent expansion of Xience Prime or Nobori stents created in SolidWorks were compared to post-operative geometry from OCT and CT before being extracted and used for CFD simulations in SimVascular. Inflow boundary conditions based on body surface area, and downstream vascular resistances and capacitances were applied at branches to mimic physiology. Artery geometries obtained after virtual expansion were in good agreement with those reconstructed from patient images. Quantitative comparison of the distance between reconstructed and post-stent geometries revealed a maximum difference in area of 20.4%. Adverse indices of wall shear stress were more pronounced for thicker Nobori stents in both patients. These findings verify structural analyses of stent expansion, introduce a workflow to combine software packages for solid and fluid mechanics analysis, and underscore important stent design features from prior idealized studies. The proposed approach may ultimately be useful in determining an optimal choice of stent and position for each patient.

  19. Long-term clinical and economic analysis of the Endeavor drug-eluting stent versus the Driver bare-metal stent: 4-year results from the ENDEAVOR II trial (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions).

    Science.gov (United States)

    Eisenstein, Eric L; Wijns, William; Fajadet, Jean; Mauri, Laura; Edwards, Rex; Cowper, Patricia A; Kong, David F; Anstrom, Kevin J

    2009-12-01

    This study was designed to evaluate long-term clinical and economic outcomes for subjects receiving Endeavor drug-eluting versus Driver bare-metal stents (both Medtronic CardioVascular, Santa Rosa, California). Early studies found that the drug-eluting stent (DES) was a clinically and economically attractive alternative to the bare-metal stent; however, associations between DES and very late stent thrombosis suggest that longer follow-up is required. We used clinical, resource use and follow-up data from 1,197 subjects randomized to receive Endeavor (n = 598) versus Driver (n = 599) stents in ENDEAVOR II (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions) study with Medicare cost weights and quality of life adjustments applied from secondary sources. We compared differences through 4-year follow-up (1,440 days). Patients in both treatment groups had similar baseline characteristics. The use of Endeavor versus Driver reduced 4-year target vessel revascularization rates per 100 subjects (10.4 vs. 21.5; difference: -11.1; 95% confidence interval [CI]: -16.0 to -6.1; p Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions [ENDEAVOR II]; NCT00614848).

  20. Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); M-C. Morice (Marie-Claude); A.P. Kappetein (Arie Pieter); A. Colombo (Antonio); D.R. Holmes Jr (David); M.J. Mack (Michael); E. Stahle (Elisabeth); T.E. Feldman (Ted); M.J.B.M. van den Brand (Marcel); E.J. Bass (Eric); N. van Dyck (Nic); K. Leadly (Katrin); K.D. Dawkins (Keith); F.W. Mohr (Friedrich)

    2009-01-01

    textabstractBACKGROUND Percutaneous coronary intervention (PCI) involving drug-eluting stents is increasingly used to treat complex coronary artery disease, although coronary-artery bypass grafting (CABG) has been the treatment of choice historically. Our trial compared PCI and CABG for treating pat

  1. Improved anticoagulation management after Palmaz Schatz coronary stent implantation by sealing the arterial puncture site with a vascular hemostasis device.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J

    1993-12-01

    Sealing the arterial puncture site with a vascular hemostasis device has the potential to maintain optimal anticoagulation after stent implantation. The level of heparinization during the first 3 days after successful stent implantation was retrospectively compared between 2 groups of medically treated patients with (group A; n = 18) and without (group B; n = 17) a Vasoseal after sheath removal. The number of APTTs sampled in group A and B was 233 and 168, respectively. Respective mean values of APTT (seconds) in group A and B were 180 +/- 79 and 172 +/- 91 at day 1 (p = NS), 132 +/- 43 and 125 +/- 61 at day 2 (p = NS) and 123 +/- 36 and 116 +/- 48 at day 3 (p = NS). More APTTs were suboptimal (< 80 secs) in group B (34/168; 20%) compared to group A (17/233; 7%) [p < 0.001]. More patients in group B compared to group A had 1 or more (14/17; 82% vs. 8/18; 44%; p = 0.04), 2 or more (10/17; 59% versus 3/18; 17%; p = 0.02) and 3 or more (8/17; 47% vs. 2/18; 11%; p = 0.03) suboptimal APTTs. Bleeding complications were seen in 4 patients without and in 3 patients with a Vasoseal. Thus application of a vascular hemostasis device results in a less variable anticoagulation after coronary stenting, but it does not abolish entry site-related bleeding complications.

  2. Everolimus-eluting coronary stents

    Directory of Open Access Journals (Sweden)

    Alejandro Saez

    2010-09-01

    Full Text Available Alejandro Saez, Raul MorenoDivision of Interventional Cardiology, University Hospital La Paz, Madrid, SpainAbstract: Bare metal stents enabled a reduction in the risk of early procedural complications and restenosis in comparison with balloon angioplasty alone, but introduced a new and device-specific iatrogenic condition, ie, in-stent restenosis due to increased neointimal hyperplasia. Sirolimus- and paclitaxel-eluting stents reduce restenosis and the need for new revascularizations in comparison with bare metal stents, although at the cost of a slight increase in the risk of late stent thrombosis and a need for prolonged dual antiplatelet therapy. Everolimus is an analog of sirolimus with an increased solubility. In this review, the currently available evidence for everolimus-eluting stents is revised, including randomized trials against bare metal stents, and head-to-head trials comparing this stent with other drug-eluting stents.Keywords: coronary stents, restenosis, everolimus, review

  3. Randomized Comparison of the Crush Versus the Culotte Stenting for Coronary Artery Bifurcation Lesions

    Institute of Scientific and Technical Information of China (English)

    Xu-Wei Zheng; Dong-Hui Zhao; Hong-Yu Peng; Qian Fan; Qin Ma; Zhen-Ye Xu; Chao Fan

    2016-01-01

    Background:The crush and the culotte stenting were both reported to be effective for complex bifurcation lesion treatment.However,their comparative performance remains elusive.Methods:A total of 300 patients with coronary bifurcation lesions were randomly assigned to crush (n =150) and culotte (n =150) treatment.The primary endpoint was the occurrence of major adverse cardiac events (MACEs) at 12 months including cardiac death,myocardial infarction,stent thrombosis,and target vessel revascularization.Index lesion restenosis at 12 months was a secondary endpoint.The surface integrals of time-averaged wall shear stress at bifurcation sites were also be quantified.Results:There were no significant differences in MACE rates between the two groups at 12-month follow-up:Crush 6.7%,culotte 5.3% (P =0.48).The rates of index lesion restenosis were 12.7% versus 6.0% (P =0.047) in the crush and the culotte groups,respectively.At 12-month follow-up,the surface integrals of time-averaged wall shear stress at bifurcation sites in the crush group were significantly lower than the culotte group ([5.01 ± 0.95] × 10-4 Newton and [6.08 ± 1.16] × 10 4 Newton,respectively;P =0.003).Conclusions:Both the crush and the culotte bifurcation stenting techniques showed satisfying clinical and angiographic results at 12-month follow-up.Bifurcation lesions treated with the culotte technique tended to have lower restenosis rates and more favorable flow patterns.

  4. Randomized Comparison of the Nobori Biolimus A9-Eluting Coronary Stent With the Taxus Liberté Paclitaxel-Eluting Coronary Stent in Patients With Stenosis in Native Coronary Arteries: The NOBORI 1 Trial—Phase 2

    National Research Council Canada - National Science Library

    Chevalier, Bernard; Silber, Sigmund; Park, Seung-Jung; Garcia, Eulogio; Schuler, Gerhard; Suryapranata, Harry; Koolen, Jacques; Hauptmann, Karl E; Wijns, William; Morice, Marie-Claude; Carrie, Didier; van Es, Gerrit-Anne; Nagai, Hirofumi; Detiege, Danny; Paunovic, Dragica; Serruys, Patrick W

    2009-01-01

    BACKGROUND—The newly developed Nobori coronary stent coated with a bioresorbable polymer, polylactic acid, and the antiproliferative agent Biolimus A9 has the potential to reduce restenosis by suppressing neointima formation...

  5. Renal Artery Stent Outcomes

    Science.gov (United States)

    Murphy, Timothy P.; Cooper, Christopher J.; Matsumoto, Alan H.; Cutlip, Donald E.; Pencina, Karol M.; Jamerson, Kenneth; Tuttle, Katherine R.; Shapiro, Joseph I.; D’Agostino, Ralph; Massaro, Joseph; Henrich, William; Dworkin, Lance D.

    2016-01-01

    BACKGROUND Multiple randomized clinical trials comparing renal artery stent placement plus medical therapy with medical therapy alone have not shown any benefit of stent placement. However, debate continues whether patients with extreme pressure gradients, stenosis severity, or baseline blood pressure benefit from stent revascularization. OBJECTIVES The study sought to test the hypothesis that pressure gradients, stenosis severity, and/or baseline blood pressure affects outcomes after renal artery stent placement. METHODS Using data from 947 patients with a history of hypertension or chronic kidney disease from the largest randomized trial of renal artery stent placement, the CORAL (Cardiovascular Outcomes in Renal Atherosclerotic Lesions) study, we performed exploratory analyses to determine if subsets of patients experienced better outcomes after stent placement than the overall cohort. We examined baseline stenosis severity, systolic blood pressure, and translesion pressure gradient (peak systolic and mean) and performed interaction tests and Cox proportional hazards analyses for the occurrence of the primary endpoint through all follow-up, to examine the effect of these variables on outcomes by treatment group. RESULTS There were no statistically significant differences in outcomes based on the examined variables nor were there any consistent nonsignificant trends. CONCLUSIONS Based on data from the CORAL randomized trial, there is no evidence of a significant treatment effect of the renal artery stent procedure compared with medical therapy alone based on stenosis severity, level of systolic blood pressure elevation, or according to the magnitude of the transstenotic pressure gradient. (Benefits of Medical Therapy Plus Stenting for Renal Atherosclerotic Lesions [CORAL]; NCT00081731) PMID:26653621

  6. Design and modeling balloon-expandable coronary stent for manufacturability

    Science.gov (United States)

    Suryawan, D.; Suyitno

    2017-02-01

    Coronary artery disease (CAD) is a disease that caused by narrowing of the coronary artery. The narrowing coronary artery is usually caused by cholesterol-containing deposit (plaque) which can cause a heart attack. CAD is the most common cause mortality in Indonesia. The commonly CAD treatment use the stent to opens or alleviate the narrowing coronary artery. In this study, the stent design is optimized for the manufacturability. Modeling is used to determine the free stent expansion due to applied pressure in the inner surface of the stent. The stress distribution, outer diameter change, and dogboning phenomena are investigated in the simulation. The result of modeling and simulating was analyzed and used to optimize the stent design before it is manufactured using EDM (Electric Discharge Machine) in the next research.

  7. Secreted Matrix Metalloproteinase-9 of Proliferating Smooth Muscle Cells as a Trigger for Drug Release from Stent Surface Polymers in Coronary Arteries.

    Science.gov (United States)

    Gliesche, Daniel G; Hussner, Janine; Witzigmann, Dominik; Porta, Fabiola; Glatter, Timo; Schmidt, Alexander; Huwyler, Jörg; Meyer Zu Schwabedissen, Henriette E

    2016-07-01

    Cardiovascular diseases are the leading causes of death in industrialized countries. Atherosclerotic coronary arteries are commonly treated with percutaneous transluminal coronary intervention followed by stent deployment. This treatment has significantly improved the clinical outcome. However, triggered vascular smooth muscle cell (SMC) proliferation leads to in-stent restenosis in bare metal stents. In addition, stent thrombosis is a severe side effect of drug eluting stents due to inhibition of endothelialization. The aim of this study was to develop and test a stent surface polymer, where cytotoxic drugs are covalently conjugated to the surface and released by proteases selectively secreted by proliferating smooth muscle cells. Resting and proliferating human coronary artery smooth muscle cells (HCASMC) and endothelial cells (HCAEC) were screened to identify an enzyme exclusively released by proliferating HCASMC. Expression analyses and enzyme activity assays verified selective and exclusive activity of the matrix metalloproteinase-9 (MMP-9) in proliferating HCASMC. The principle of drug release exclusively triggered by proliferating HCASMC was tested using the biodegradable stent surface polymer poly-l-lactic acid (PLLA) and the MMP-9 cleavable peptide linkers named SRL and AVR. The specific peptide cleavage by MMP-9 was verified by attachment of the model compound fluorescein. Fluorescein release was observed in the presence of MMP-9 secreting HCASMC but not of proliferating HCAEC. Our findings suggest that cytotoxic drug conjugated polymers can be designed to selectively release the attached compound triggered by MMP-9 secreting smooth muscle cells. This novel concept may be beneficial for stent endothelialization thereby reducing the risk of restenosis and thrombosis.

  8. Multi-link Vision and MiniVision stent registry in Asian patients with coronary artery disease: a prospective, multi-center study.

    Science.gov (United States)

    Xu, Ya-Wei; Wei, Yi-Dong; Tang, Kai; Chen, Yan-Qing; Li, Wei-Ming; Yu, Xue-Jing; Qin, Yong-Wen; Qi, Guo-Xian; Qu, Peng; Hou, Yu-Qing; Jain, Ashok; Grant, Parvez; Ramesh, Gudapati; Ramesh, Basavappa; Piamsomboon, Chumpol; Kuanprasert, Srun; Gwon, Hyeon-Cheol; Cho, Yoon Haeng; Kamar, Haizal Haroon; Huang, Cong-Xin

    2007-06-20

    Recent studies have showed that the fine mesh stents are associated with a significant reduction in both clinical and angiographic re-stenosis of the coronary arteries. To maintain a very satisfactory radio-opacity using the stents, Guidant of the USA has designed a new type of bare metal stents (BMS)-Multi-link (ML) Vision/ML MiniVision stents. The clinical outcomes of Asian patients with coronary artery disease (CAD) after implanting the Multi-link Vision or MiniVision stent were investigated in this study. An observational, prospective, multi-center, non-randomized post marketing registry was conducted to demonstrate the efficacy of the BMS-ML Vision/ML MiniVision stents. The primary end point of the registry was clinical target lesion revascularization (TLR) at a 6-month follow-up. The major secondary end points included the rate of major adverse cardiac events (MACE) and serious adverse events (SAE) in hospital and at 6 months; and the rate of clinical TLR as a function of the type of angina. A total of 429 Asian people with 449 lesions from 14 centers were selected for this study. The average reference diameter of the lesions was (3.0 +/- 0.5) mm, and the mean length was (15.7 +/- 5.0) mm. The successful rate of the procedure was 99.3%. Twenty-five percent of the lesions were treated by direct stenting without pre-dilation. Eighty-six percent of the lesions were implanted with ML Vision stent. After the 6-month follow-up, the rate of clinical TLR was 1.4%. The MACE, SAE and target vessel revascularization (TVR) were 6.8%, 3.5% and 1.4% respectively. The current registry showed the excellent 6-month clinical outcomes of ML Vision/ML MiniVision stents in Asian patients with CAD.

  9. Six-month clinical outcomes of Firebird 2TM sirolimus-eluting stent implantation in real-world patients with coronary artery diseases

    Institute of Scientific and Technical Information of China (English)

    GE Jun-bo; ZHANG Feng; QIAN Ju-ying; GE Lei; LIU Xue-bo; ZHOU Jun

    2011-01-01

    Background The Firebird 2TM sirolimus-eluting stent (Firebird 2 stent) is a second-generation sirolimus-eluting stent which has a cobalt-chromium alloy stent platform, a brand new bracket structure, and two layers of styrene-butylenes-styrene polymer coatings with better biocompatibility. The Firebird 2TM cObalt-Chromium alloy sirolimus-elUting Stent registry (FOCUS registry) aimed to evaluate the safety and efficacy of the Firebird 2 stent in patients with coronary artery disease in daily practice.Methods The FOCUS registry is a prospective, non-randomized, international multi-center, single-arm clinical registry.Between March 2009 and February 2010, 5084 patients receiving at least 1 Firebird 2 stent during daily clinical practice at 83 medical centers were enrolled.Results Of the 5084 patients enrolled in the registry, 5077 and 5058 were respectively available for 30 days and 6 months follow-up. The 30-day rate of major adverse cardiac events (MACE) was 1.20%, including 13 cardiac deaths, 46 non-fatal myocardial infarction (MI), and 6 target vessel revascularization (TVR). At 6 months follow-up, the rate of MACE was 1.80%. There were 32 cardiac deaths, 48 non-fatal MI, and 15 TVR. According to the Academic Research Consortium definition, definite/probable stent thrombosis (ST) occurred in 0.43% (22/5058) of patients, including 8 cases of acute ST, 11 subacute ST, and 3 late ST.Conclusion The Firebird 2 stent showed the promising efficacy and safety at 30 days and 6 months in a real-world population of patients with coronary artery diseases.

  10. Multi-link Vision and MiniVision stent registry in Asian patients with coronary artery disease: a prospective, multi-center study

    Institute of Scientific and Technical Information of China (English)

    XU Ya-wei; HOU Yu-qing; Ashok Jain; Parvez Grant; Gudapati Ramesh; Basavappa Ramesh; Chumpol Piamsomboon; Srun Kuanprasert; Hyeon-Cheol Gwon; Yoon Haeng Cho; Haizal Haroon Kamar; WEI Yi-dong; HUANG Cong-xin; TANG Kai; CHEN Yan-qing; LI Wei-ming; YU Xue-jing; QIN Yong-wen; QI Guo-xian; QU Peng

    2007-01-01

    Background Recent studies have showed that the fine mesh stents are associated with a significant reduction in both clinical and angiographic re-stenosis of the coronary arteries. To maintain a very satisfactory radio-opacity using the stents, Guidant of the USA has designed a new type of bare metal stents (BMS)-Multi-link (ML) Vision / ML MiniVision stents. The clinical outcomes of Asian patients with coronary artery disease (CAD) after implanting the Multi-link Vision or MiniVision stent were investigated in this study.Methods An observational, prospective, multi-center, non-randomized post marketing registry was conducted to demonstrate the efficacy of the BMS- ML Vision / ML MiniVision stents. The primary end point of the registry was clinical target lesion revascularization (TLR) at a 6-month follow-up. The major secondary end points included the rate of major adverse cardiac events (MACE) and serious adverse events (SAE) in hospital and at 6 months; and the rate of clinical TLR as a function of the type of angina. A total of 429 Asian people with 449 lesions from 14 centers were selected for this study. The average reference diameter of the lesions was (3.0±0.5) mm, and the mean length was (15.7±5.0) mm.Results The successful rate of the procedure was 99.3%. Twenty-five percent of the lesions were treated by direct stenting without pre-dilation. Eighty-six percent of the lesions were implanted with ML Vision stent. After the 6-month follow-up, the rate of clinical TLR was 1.4%. The MACE, SAE and target vessel revascularization (TVR) were 6.8%, 3.5%and 1.4% respectively.Conclusion The current registry showed the excellent 6-month clinical outcomes of ML Vision/ML MiniVision stents in Asian patients with CAD.

  11. Drug- and Gene-eluting Stents for Preventing Coronary Restenosis

    Science.gov (United States)

    Lekshmi, Kamali Manickavasagam; Che, Hui-Lian; Cho, Chong-Su

    2017-01-01

    Coronary artery disease (CAD) has been reported to be a major cause of death worldwide. Current treatment methods include atherectomy, coronary angioplasty (as a percutaneous coronary intervention), and coronary artery bypass. Among them, the insertion of stents into the coronary artery is one of the commonly used methods for CAD, although the formation of in-stent restenosis (ISR) is a major drawback, demanding improvement in stent technology. Stents can be improved using the delivery of DNA, siRNA, and miRNA rather than anti-inflammatory/anti-thrombotic drugs. In particular, genes that could interfere with the development of plaque around infected regions are conjugated on the stent surface to inhibit neointimal formation. Despite their potential benefits, it is necessary to explore the various properties of gene-eluting stents. Furthermore, multifunctional electronic stents that can be used as a biosensor and deliver drug- or gene-based on physiological condition will be a very promising way to the successful treatment of ISR. In this review, we have discussed the molecular mechanism of restenosis, the use of drug- and gene-eluting stents, and the possible roles that these stents have in the prevention and treatment of coronary restenosis. Further, we have explained how multifunctional electronic stents could be used as a biosensor and deliver drugs based on physiological conditions. PMID:28184335

  12. [Ability to Overcome the Thrombocyte Resistance to Acetylsalicylic Acid in Patients With Coronary Artery Disease After Myocardial Revascularization With Coronary Stenting].

    Science.gov (United States)

    Pershukov, I V; Ostaschenko, S L; Kuznetsova, T N; Scherbo, S N; Karben, Z A; Sokryukina, E V; Omarov, A A; Ramazanov, D M; Bosak, N V; Shulzhenko, L V; Kalmatov, R K; Batyraliev, T A; Sidorenko, B A

    2016-07-01

    Resistance to acetylsalicylic acid (ASA) in patients with coronary artery disease is a poor predictor for the development of atherothrombotic complications. In 277 patients with coronary artery disease suffered uncomplicated coronary angioplasty with stent implantation, we was estimated arachidon-induced platelet aggregation during treatment with acetylsalicylic acid by bedside VerifyNow Assay test at 28-90 days after the intervention. It was found that 18.9% of the 144 patients receiving a combination of ASA 75 mg with 15.2 mg of magnesium hydroxide had true (laboratory) resistance to ASA. At the same time on the original enteric coated ASA 100 mg, we can found only 0.8% resistance to ASA among 129 patients. We made switch from combination of ASA 75 mg with 15.2 mg of magnesium hydroxide to original enteric coated ASA 100 mg and repeat VerifyNow Assay test at 2-4 days and found lost of resistance in 92% of 28 patients. Thus, resistance to the ASA is not constant, it depends on the form and the applied dose of ASA, and eliminating more than 92% when ASA changes from ineffective to effective form.

  13. Prognostic Value of Plasma Pentraxin-3 Levels in Patients with Stable Coronary Artery Disease after Drug-Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Liu Haibo

    2014-01-01

    Full Text Available Pentraxin-3 (PTX3 is an inflammatory marker thought to be more specific to cardiovascular inflammation than C-reactive protein (CRP. Our aim was to assess the prognostic value of PTX3 in patients with stable coronary artery disease (CAD after drug eluting stent (DES implantation. Plasma PTX3 levels were measured before percutaneous coronary intervention (PCI and at 24 h post-PCI in 596 consecutive patients with stable CAD. Patients were followed up for a median of 3 years (range 1–5 for major adverse cardiovascular events (MACEs. We found that the post-PCI plasma PTX3 levels were significantly higher at 24 h after PCI than pre-PCI, patients with MACEs had higher post-PCI PTX3 levels compared with MACEs-free patients, patients with higher post-PCI PTX3 levels (median > 4.384 ng/mL had a higher risk for MACEs than those with PTX3 < 4.384 ng/mL, and post-PCI PTX3, cTnI, multiple stents, and age but not high-sensitivity CRP (hsCRP were independently associated with the prevalence of MACEs after DES implantation. The present study shows that post-PCI PTX3 may be a more reliable inflammatory predictor of long-term MACEs in patients with stable CAD undergoing DES implantation than CRP. Measurement of post-PCI PTX3 levels could provide a rationale for risk stratification of patients with stable CAD after DES implantation.

  14. Extended Duration Dual Antiplatelet Therapy After Coronary Stenting Among Patients With Peripheral Arterial Disease: A Subanalysis of the Dual Antiplatelet Therapy Study.

    Science.gov (United States)

    Secemsky, Eric A; Yeh, Robert W; Kereiakes, Dean J; Cutlip, Donald E; Steg, P Gabriel; Massaro, Joseph M; Apruzzese, Patricia K; Mauri, Laura

    2017-05-08

    This study sought to determine whether patients with peripheral arterial disease (PAD) experience different reductions in ischemic event and increases in bleeding events with extended duration dual antiplatelet therapy versus those without PAD. Patients with PAD have increased ischemic and bleeding risks after coronary stenting. The DAPT (Dual Antiplatelet Therapy) study randomized 11,648 patients free from ischemic and bleeding events 12 months after coronary stenting to continued thienopyridine plus aspirin therapy for an additional 18 months versus aspirin therapy alone. The effects of continued thienopyridine on myocardial infarction (MI) or stent thrombosis, major adverse cardiovascular and cerebrovascular events (death, MI, or stroke) and bleeding (GUSTO [Global Utilization of t-PA and Streptokinase for Occluded Coronary Arteries] moderate or severe) were assessed among those with versus without PAD. Among 11,648 randomized patients, 649 (5.57%) had PAD. Between 12 and 30 months, randomized patients with PAD had higher rates of MI/stent thrombosis (6.03% vs. 2.92%; p antiplatelet therapy is associated with consistent ischemic benefit and bleeding harm among patients with and without PAD. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. An epidural catheter removal after recent percutaneous coronary intervention and coronary artery stenting: Epidural catheter and antiaggregation therapy

    Directory of Open Access Journals (Sweden)

    Joksić Nikola

    2016-01-01

    Full Text Available Introduction: Anticoagulation and antiplatelet therapy in the presence of the epidural catheter is still controversial. It is well known that dual antiplatelet therapy is indicated for 12 months after the placement of drug-eluting stents (DES. Removal of an epidural catheter during that period is related to an increased risk of stent occlusion in case of discontinuation of platelet function inhibitors or, on the other hand, increased risk of epidural hematoma associated with neurological deficit if suppressed platelet function is still present. Case Report: Here we present a case of a 63-year-old man who was admitted to Institute for Cardiovascular Diseases Dedinje for elective aortic surgery. Before the induction, an epidural catheter was inserted at the Th10-Th11 epidural space. Uneventful surgery was performed under the combined epidural and general anesthesia. On the 2nd postoperative day, the patient sustained a ST depression myocardial infarction treated with percutaneous coronary intervention with DES placement, while epidural catheter was still in place. Dual antiplatelet therapy with 600mg of clopidogrel, 100 mg of acetilsalicylic acid (ASA and low molecular weight heparin (LMWH were started during the procedure. The next day, clopidogrel (75 mg and ASA (100 mg were continued as well as LMWH. The decision to remove the epidural catheter was made on the 9th postoperative day, after platelet aggregation assays were performed. Six hours after catheter removal the patient again received clopidogrel, ASA and LMWH. There were no signs of epidural hematoma. Conclusion: This case shows that point-of-care testing with platelet aggregation assays may be useful in increasing the margin of safety for epidural catheter removal during dual antiplatelet therapy.

  16. Airport and superficial femoral artery obstruction due to a wandering coronary stent: the possibility of airport detection of modern implant metals.

    Science.gov (United States)

    Teijink, J A W; van Herwaarden, J A; van den Berg, J C; Overtoom, T C; Moll, F L

    2004-06-01

    In the treatment of coronary artery disease, peripheral loss of a coronary stent is an unusual complication. We present the case of a patient who suggested that his right leg claudication was caused by a slipped coronary stent 2 years previously. The patient was convinced about this unusual finding based on an airport security check. Examination proved him to be right. However, the ability to detect an object using eddy currents is dependent on the object's permeability and its conductivity. Ferrous (iron) content is not the critical factor. Modern implant materials and processing techniques result in implants that are difficult to magnetize i.e. their permeability is very low. In addition their conductivity is very low. This enables modern implants to escape detection at airports. For this reason the event at the airport, as described by our patient, is considered coincidental.

  17. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner® catheter to deliver stents for anomalous right coronary artery

    Directory of Open Access Journals (Sweden)

    Toshiki Kuno

    2015-10-01

    Full Text Available Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  18. Age-based clinical and angiographic outcomes after sirolimus-eluting stent implantation in patients with coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    XU Bo; WU Yong-jian; YUAN Jin-qing; CHEN Jue; YOU Shi-jie; DAI Jun; XIA Ran; GAO Run-lin; LI Jian-jun; YANG Yue-jin; CHEN Ji-lin; QIAO Shu-bin; QIN Xue-wen; MA Wei-hua; YAO Min; LIU Hai-bo

    2007-01-01

    Background Advanced age independently predicts early and late mortality and major adverse cardiac events (MACE)after percutaneous coronary intervention (PCI). Randomized clinical trials indicate that sirolimus-eluting stent (SES)implantation reduces target lesion revascularization (TLR), but there are limited data on the impact of age on outcomes following SES implantation in patients with coronary artery disease (CAD) in real-world practice.Methods A total of 333 CAD patients with 453 lesions were enrolled in this study. Subjects were divided into two groups according to age. a young group (<65 years old, 244 patients with 369 lesions) and elderly group (≥65 years old, 89patients with 113 lesions). Clinical follow-up and quantitative coronary angiography (QCA) were performed seven months after PCI.Results Baseline clinical, demographic, angiographic, and procedural chararcteristics were similar in both groups,except that there were more female patients in the elderly group (21.3% vs 9.8%, P=0.006). Primary success rate was similar in both groups (96.5% in young group vs 95.7% in elderly group, P>0.05). During angiographic follow-up at 7months, binary in-stent restenosis and in-segment restenosis rates were not significantly different between the two groups (4.7% vs 1.8%; 9.7% vs 8.8%, P>0.05 respectively). Both sub-acute and late thrombosis rates were similar in the two groups (0.3% vs 0.9% and 1.2% vs 0.9%, P>0.05 respectively). TLR was not significantly different between the two groups (6.5% vs 3.5%; P=0.246). The rates of bleeding, stroke, angina rehospitalization during the follow-up period were also similar in both groups (P>0.05 respectively).Conclusion Despite a high-risk clinical profile, coronary SES implantation can be safely and effectively performed in elderly patients with a similar procedural success rate, a low complication rate, and excellent 7-month outcomes.

  19. 经桡动脉冠状动脉支架植入术后的护理%Nursing after via radial artery coronary artery stent implantation

    Institute of Scientific and Technical Information of China (English)

    李少晶

    2016-01-01

    Objective:To explore the postoperative nursing of via radial artery coronary artery stent implantation in the treatment of coronary heart disease.Methods:215 patients with coronary heart disease were given via radial artery coronary artery stent implantation.The postoperative nursing situation was observed.Results:215 patients were successfully completed surgery.2 cases occurred complications after operation,including 1 case of acute myocardial ischemia and 1 case of false aneurysm.They were treated in a timely manner.The patients recovered and discharged.Conclusion:Nursing staff should enhance the understanding,pay attention to the postoperative observation and nursing,systemly master the clinical features,timely find out various problems,report to the doctor,so that they can give timely effective treatment.Through actively taking comprehensive nursing measures is conducive to the patient's recovery as soon as possible,reduce the complications.%目的:探讨经桡动脉冠状动脉内支架植入术治疗冠心病的术后护理。方法:对215例冠心病患者给予经桡动脉冠状动脉内支架植入术,观察术后护理情况。结果:215例患者皆顺利完成手术治疗,术后出现并发症2例,包括急性心肌缺血1例及假性动脉瘤1例,均得到及时处理,患者康复出院。结论:护理人员应提高认识,重视术后的观察及护理,系统掌握其临床特点,及时发现各种问题,报告医生,以便及时、有效地处理,通过积极采取综合护理措施,有利于患者的尽快康复,减少并发症。

  20. Development of radiolabelled compound using reactor producted RI - Evaluation of Ho-166 endovascular therapy to prevent restenosis after PTCA or stenting for occlusive coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Hee; Choi, Byung Il; Kim, Han Soo [Ajou University, Suwon (Korea)

    2000-04-01

    Occlusive coronary artery disease is managed successfully by percutaneous transfemoral coronary angioplasty (PTCA) or stenting with 95% success rate. However, restenosis after PTCA is not uncommon and the reported incidence of reocclusion is about 30 {approx} 40%. Therefore, the objective of the research was to develop endovascular brachytherapy using liquid form of Ho-166 in order to inhibit neointimal hyperplasia responsible for restenosis following PTCA or stenting. Our research was carried out in 3 stages: First stage - The effectiveness of radiation was confirmed by using animal model. Following over-sized balloon injury to rat carotid artery and porcine coronary artery, various external radiation doses were delivered. Second stage - For radiation dose distribution within the coronary artery and its surrounding tissues, Gafchromic film was used. In vitro dose distribution of Ho-166 utilizing water phantom and Gafchromic film was measured. Third stage - None uniform dose distribution from Ho-166 within the balloon caused by small air bubbles was eliminated by negative suction method. More accurate dose distribution was also possible using newly developed micrometer by our physicist. Limited number of human trial was performed without adverse effect. 40 refs. (Author)

  1. Coronary stent on coronary CT angiography: Assessment with model-based iterative reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Chae; Kim, Yeo Koon; Chun, Eun Ju; Choi, Sang IL [Dept. of of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-05-15

    To assess the performance of model-based iterative reconstruction (MBIR) technique for evaluation of coronary artery stents on coronary CT angiography (CCTA). Twenty-two patients with coronary stent implantation who underwent CCTA were retrospectively enrolled for comparison of image quality between filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and MBIR. In each data set, image noise was measured as the standard deviation of the measured attenuation units within circular regions of interest in the ascending aorta (AA) and left main coronary artery (LM). To objectively assess the noise and blooming artifacts in coronary stent, we additionally measured the standard deviation of the measured attenuation and intra-luminal stent diameters of total 35 stents with dedicated software. All image noise measured in the AA (all p < 0.001), LM (p < 0.001, p = 0.001) and coronary stent (all p < 0.001) were significantly lower with MBIR in comparison to those with FBP or ASIR. Intraluminal stent diameter was significantly higher with MBIR, as compared with ASIR or FBP (p < 0.001, p = 0.001). MBIR can reduce image noise and blooming artifact from the stent, leading to better in-stent assessment in patients with coronary artery stent.

  2. Successful percutaneous coronary intervention for chronic total occlusion of right coronary artery in patient with dextrocardia.

    Science.gov (United States)

    Munawar, Muhammad; Hartono, Beny; Iskandarsyah, Kurniawan; Nguyen, Thach N

    2013-07-01

    Situs inversus with dextrocardia is rare congenital anomaly. Coronary artery disease in such patients is quite rare. We reported a 52-year-old man with dextrocardia and chronic total occlusion at the proximal right coronary artery just after conus branch and severe stenosis at the proximal left anterior descending artery. He underwent successful percutaneous coronary intervention with stenting of total occluded right coronary artery and simultaneously stenting of the proximal left anterior descending artery.

  3. Revascularisation versus medical treatment in patients with stable coronary artery disease

    DEFF Research Database (Denmark)

    Windecker, Stephan; Stortecky, Stefan; Stefanini, Giulio G;

    2014-01-01

    OBJECTIVE: To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. DESIGN: Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials...... stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. DATA SOURCES: Medline and Embase from 1980......: Among patients with stable coronary artery disease, coronary artery bypass grafting reduces the risk of death, myocardial infarction, and subsequent revascularisation compared with medical treatment. All stent based coronary revascularisation technologies reduce the need for revascularisation...

  4. A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary Arteries IV study

    Directory of Open Access Journals (Sweden)

    Teeuwen Koen

    2012-12-01

    Full Text Available Abstract Background Percutaneous recanalization of total coronary occlusion (TCO was historically hampered by high rates of restenosis and reocclusions. The PRISON II trial demonstrated a significant restenosis reduction in patients treated with sirolimus-eluting stents compared with bare metal stents for TCO. Similar reductions in restenosis were observed with the second-generation zotarolimus-eluting stent and everolimus-eluting stent. Despite favorable anti-restenotic efficacy, safety concerns evolved after identifying an increased rate of very late stent thrombosis (VLST with drug-eluting stents (DES for the treatment of TCO. Late malapposition caused by hypersensitivity reactions and chronic inflammation was suggested as a probable cause of these VLST. New DES with bioresorbable polymer coatings were developed to address these safety concerns. No randomized trials have evaluated the efficacy and safety of the new-generation DES with bioresorbable polymers in patients treated for TCO. Methods/Design The prospective, randomized, single-blinded, multicenter, non-inferiority PRISON IV trial was designed to evaluate the safety, efficacy, and angiographic outcome of hybrid sirolimus-eluting stents with bioresorbable polymers (Orsiro; Biotronik, Berlin, Germany compared with everolimus-eluting stents with durable polymers (Xience Prime/Xpedition; Abbott Vascular, Santa Clara, CA, USA in patients with successfully recanalized TCOs. In total, 330 patients have been randomly allocated to each treatment arm. Patients are eligible with estimated duration of TCO ≥4 weeks with evidence of ischemia in the supply area of the TCO. The primary endpoint is in-segment late luminal loss at 9-month follow-up angiography. Secondary angiographic endpoints include in-stent late luminal loss, minimal luminal diameter, percentage of diameter stenosis, in-stent and in-segment binary restenosis and reocclusions at 9-month follow-up. Additionally, optical coherence

  5. Coronary Stents: The Impact of Technological Advances on Clinical Outcomes.

    Science.gov (United States)

    Mennuni, Marco G; Pagnotta, Paolo A; Stefanini, Giulio G

    2016-02-01

    Percutaneous coronary interventions (PCI) were proposed in the late 1970s as an alternative to surgical coronary artery bypass grafting for the treatment of coronary artery disease. Important technological progress has been made since. Balloon angioplasty was replaced by bare metal stents, which allowed to permanently scaffold the coronary vessel avoiding acute recoil and abrupt occlusion. Thereafter, the introduction of early generation drug-eluting stents (DES) has significantly improved clinical outcomes, primarily by markedly reducing the risk of restenosis. New generation DES with thinner stent struts, novel durable or biodegradable polymer coatings, and new limus antiproliferative agents, have further improved upon the safety and efficacy profile of early generation DES. The present article aims to review the impact of technological advances on clinical outcomes in the field of PCI with coronary stents, and to provide a brief overview on clinical margins of improvement and unmet needs of available DES.

  6. Coronary stenting: A matter of revascularization.

    Science.gov (United States)

    Bonaventura, Aldo; Montecucco, Fabrizio; Liberale, Luca

    2017-03-26

    In the last few decades, the recommended treatment for coronary artery disease has been dramatically improved by percutaneous coronary intervention (PCI) and the use of balloon catheters, bare metal stents (BMSs), and drug-eluting stents (DESs). Catheter balloons were burdened by acute vessel occlusion or target-lesion re-stenosis. BMSs greatly reduced those problems holding up the vessel structure, but showed high rates of in-stent re-stenosis, which is characterized by neo-intimal hyperplasia and vessel remodeling leading to a re-narrowing of the vessel diameter. This challenge was overtaken by first-generation DESs, which reduced re-stenosis rates to nearly 5%, but demonstrated delayed arterial healing and risk for late in-stent thrombosis, with inflammatory cells playing a pivotal role. Finally, new-generation DESs, characterized by innovations in design, metal composition, surface polymers, and anti-proliferative drugs, finally reduced the risk for stent thrombosis and greatly improved revascularization outcomes. New advances include bioresorbable stents potentially changing the future of revascularization techniques as the concept bases upon the degradation of the stent scaffold to inert particles after its function expired, thus theoretically eliminating risks linked with both stent thrombosis and re-stenosis. Talking about DESs also dictates to consider dual antiplatelet therapy (DAPT), which is a fundamental moment in view of the good outcome duration, but also deals with bleeding complications. The better management of patients undergoing PCI should include the use of DESs and a DAPT finely tailored in consideration of the potentially developing bleeding risk in accordance with the indications from last updated guidelines.

  7. Preliminary Evaluation of Clinical and Angiographic Outcomes with Biodegradable Polymer Coated Sirolimus-Eluting Stent in De Novo Coronary Artery Disease: Results of the MANIPAL-FLEX Study

    Directory of Open Access Journals (Sweden)

    Ranjan Shetty

    2016-01-01

    Full Text Available Objective. The objective of the MANIPAL-FLEX study was to evaluate the feasibility, preliminary safety, and efficacy of the Supraflex sirolimus-eluting stent (SES implantation, in de novo coronary artery disease, using clinical and quantitative coronary angiography (QCA follow-ups. Methods. This was a prospective, nonrandomized, multicenter, single-arm study that enrolled 189 patients with de novo coronary artery disease who were treated with the Supraflex SES. Of 189 patients enrolled, the first 61 consecutive patients who consented to a 9-month follow-up evaluation by QCA, irrespective of presence of symptoms, were to be followed up with angiography at 9 months. The primary endpoint of the study was target lesion failure (TLF, including cardiac death, myocardial infarction, and target lesion revascularization during 12-month follow-up after the index procedure. Results. The mean age of the study population was 58±11 years, with 51.3% (97/189 of hypertensive patients. Total of 66 lesions, analyzed by offline QCA, showed good scaffolding of the target vessel with in-stent late lumen loss at 9 months of 0.18±0.23 mm. The observed TLF at 30-day, 6-month, and 12-month follow-up were 2 (1.1%, 6 (3.2%, and 10 (5.3%, respectively. Conclusion. This study provides preliminary evidence for the feasibility, safety, and efficacy of the Supraflex sirolimus-eluting stent.

  8. Impact of cardiac rehabilitation on angiographic outcomes after drug-eluting stents in patients with de novo long coronary artery lesions.

    Science.gov (United States)

    Lee, Jong-Young; Yun, Sung-Cheol; Ahn, Jung-Min; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Lee, Cheol Whan; Park, Seong-Wook; Yoo, Yeong Sook; Park, Eun-Kyung; Jin, Young-Soo; Kim, Jeongsoon; Nam, Hyo-Jung; Min, Sun-Yang; Park, Seung-Jung

    2014-06-15

    Cardiac rehabilitation (CR) can reduce cardiovascular mortality and morbidity in coronary artery disease. Long coronary artery lesions may be associated with adverse outcomes after drug-eluting stent (DES) implantation. The purpose of this study was to evaluate angiographic outcomes after a comprehensive CR program in patients with DESs for long coronary artery lesions. A total of 576 patients treated with DESs for long (≥25 mm) coronary lesions were enrolled in this prospective CR registry. Comprehensive CR programs were successfully performed in 288 patients (50%). The primary end point was in-stent late luminal loss at the 9-month angiographic follow-up. There were few significant differences between the CR and non-CR groups in terms of baseline characteristics, including clinical, angiographic, and procedural variables. The rate of in-stent late luminal loss in the CR group was 35% less than in the usual care group (0.19 ± 0.33 mm in CR vs 0.29 ± 0.45 mm in non-CR, difference 0.08 mm, 95% confidence interval 0.01 to 0.16, p = 0.02) at the 9-month follow-up. After propensity-matched analysis (224 pairs), the results were consistent (0.18 ± 0.31 mm in CR vs 0.28 ± 0.41 mm in non-CR, difference 0.10 mm, 95% confidence interval 0.02 to 0.18, p = 0.02). The CR group showed a significant improvement in the overall risk profile compared with the non-CR group, including current smoking, biochemical profiles, depression, obesity, and exercise capacity. In conclusion, the comprehensive CR program significantly reduced late luminal loss after DES implantation for long coronary lesions. This may be associated with significant improvements in exercise capacity and overall risk profile.

  9. Incidence and Potential Mechanism(s) of Post-Procedural Rise of Cardiac Biomarker in Patients With Coronary Artery Narrowing After Implantation of an Everolimus-Eluting Bioresorbable Vascular Scaffold or Everolimus-Eluting Metallic Stent

    DEFF Research Database (Denmark)

    Ishibashi, Yuki; Muramatsu, Takashi; Nakatani, Shimpei;

    2015-01-01

    to Compare the Safety, Efficacy, and Performance of Absorb Everolimus Eluting Bioresorbable Vascular Scaffold System Against Xience Everolimus Eluting Coronary Stent System in the Treatment of Subjects With Ischemic Heart Disease Caused by De Novo Native Coronary Artery Lesions [ABSORB II]; NCT01425281)....

  10. Late-term clinical outcomes with zotarolimus- and sirolimus-eluting stents. 5-year follow-up of the ENDEAVOR III (A Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions).

    Science.gov (United States)

    Kandzari, David E; Mauri, Laura; Popma, Jeffrey J; Turco, Mark A; Gurbel, Paul A; Fitzgerald, Peter J; Leon, Martin B

    2011-05-01

    This study sought to compare late safety and efficacy outcomes following percutaneous coronary revascularization with zotarolimus-eluting stents (ZES) and sirolimus-eluting stents (SES). Despite higher late lumen loss and binary restenosis with ZES compared with SES, it is uncertain whether differences in early angiographic measures translate into more disparate late clinical events. Clinical outcomes were prospectively evaluated through 5 years in the ENDEAVOR III (A Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) that randomized 436 patients of relatively low anatomic and clinical risk to treatment with ZES (n = 323) or SES (n = 113) and evaluated a primary endpoint of 8-month angiographic late lumen loss. At 5 years (completeness of follow-up: 95.2%), pre-specified endpoints of all-cause mortality (5.2% vs. 13.0%, p = 0.02), myocardial infarction (1.0% vs. 4.6%, p = 0.03), and the composite event rates of cardiac death/myocardial infarction (1.3% vs. 6.5%, p = 0.009) and major adverse cardiac events (14.0% vs. 22.2%, p = 0.05) were significantly lower among patients treated with ZES. Rates of target lesion (8.1% ZES vs. 6.5% SES, p = 0.68) and target vessel revascularization were similar between treatment groups. Stent thrombosis was infrequent and similar in both groups (0.7% ZES vs. 0.9% SES, p = 1.0). Between 9 months and 5 years, progression of major adverse cardiac events was significantly more common with SES than with ZES (16.7% vs. 7.8%, p = 0.015). Despite initially higher angiographic late lumen loss, rates of clinical restenosis beyond the protocol-specified angiographic follow-up period remain stable with ZES compared with the rates for SES, resulting in similar late-term efficacy. Over 5 years, significant differences in death, myocardial infarction, and composite endpoints favored treatment with ZES

  11. Effectiveness of sirolimus-eluting stent implantation for the treatment of coronary artery disease in octogenarians.

    Science.gov (United States)

    Vijayakumar, Maniyal; Lemos, Pedro A; Hoye, Angela; Ong, Andrew T L; Aoki, Jiro; Granillo, Gaston Rodriguez; McFadden, Eugene P; Sianos, Georgios; Hofma, Sjoerd H; Smits, Pieter C; van der Giessen, Willem J; de Feyter, Pim; van Domburg, Ron T; Cummins, Paul A; Serruys, Patrick W

    2004-10-01

    Sirolimus-eluting stent (SES) implantation has been shown to reduce repeat revascularization in various randomized trials. The present study evaluated the outcomes after SES implantation in 46 octogenarian patients. SES implantation in octogenarians appears to be feasible and is associated with very small subsequent need for repeat target vessel revascularization at 1 year.

  12. Immediate and long-term results of a modified simultaneous kissing stenting for percutaneous coronary intervention of coronary artery bifurcation lesions.

    Science.gov (United States)

    Isaaz, Karl; Bayle, Sandrine; Lamaud, Michel; Robin, Christophe; Cerisier, Alexis; Mayaud, Norbert; Richard, Laure; Sabry, Mohamed Hassan; Khamis, Hazem; Abd-Alaziz, Ahmad; Da Costa, Antoine

    2013-03-01

    We propose a modified simultaneous kissing stenting technique (MSKS) based on systematic implantation of a protective stent in the proximal main vessel (PMV) proximally to the bifurcation before simultaneous kissing stenting (SKS). SKS has been proposed in large-size coronary vessel bifurcation lesions (BLs) when the PMV can accommodate two stents. SKS implies, however, low-pressure simultaneous final balloon inflations to avoid retrograde PMV dissection or rupture and therefore may not ensure optimal final stent apposition. From January 2005 to May 2008, a total of 97 patients with 100 BLs (true bifurcation in 92%) who underwent MSKS were enrolled in a prospective registry. Drug-eluting stents were used for distal main vessel and side branch. Drug-eluting or large-size bare-metal stents were used as proximal protective stents. Immediate procedural success rate was 100%. Global restenosis rate was 10% (5% in the main vessel and 8% in the side branch) at follow-up angiogram performed at 7 months in all patients (100%). No patient had early or late stent thrombosis. Two cases of non-fatal very late stent thrombosis occurred at 46 and 64 months. Over a mean 4.5-year follow-up period, target lesion revascularization rate was 11%, with only 3% driven by clinical ischemia. Protective stent systematic implantation in the PMV represents a newly modified SKS technique that allows safe finalization of the procedure by high-pressure kissing balloon final inflation, ensuring optimal stent apposition with high immediate procedural success and low rates of long-term events.

  13. Anomalous origin of right coronary artery from left coronary sinus.

    Science.gov (United States)

    Hamzeh, Gadah; Crespo, Alex; Estarán, Rafael; Rodríguez, Miguel A; Voces, Roberto; Aramendi, José I

    2008-08-01

    Anomalous aortic origin of the coronary arteries is uncommon but clinically significant. Manifestations vary from asymptomatic patients to those who present with angina pectoris, myocardial infarction, heart failure, syncope, arrhythmias, and sudden death. We describe 4 patients, aged 34 to 59 years, who were diagnosed with right coronary artery arising from the left sinus of Valsalva, confirmed by coronary angiography, which was surgically repaired. Three patients presented dyspnea and angina, and one with acute myocardial infarction. At operation, the right coronary artery was dissected at the take-off from the intramural course, and reimplanted into the right sinus of Valsalva. There was no mortality. One patient had associated coronary artery disease that required stent placement postoperatively. This reimplantation technique provides a good physiological and anatomical repair, eliminates a slit-like ostium, avoids compression of the coronary artery between the aorta and the pulmonary artery, and gives superior results to coronary artery bypass grafting or the unroofing technique.

  14. A new approach to the assessment of lumen visibility of coronary artery stent at various heart rates using 64-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Groen, J.M.; Greuter, M.J.W.; Ooijen, P.M.A. van; Oudkerk, M. [University Medical Center Groningen, University of Groningen, Department of Radiology, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands)

    2007-07-15

    Coronary artery stent lumen visibility was assessed as a function of cardiac movement and temporal resolution with an automated objective method using an anthropomorphic moving heart phantom. Nine different coronary stents filled with contrast fluid and surrounded by fat were scanned using 64-slice multi-detector computed tomography (MDCT) at 50-100 beats/min with the moving heart phantom. Image quality was assessed by measuring in-stent CT attenuation and by a dedicated tool in the longitudinal and axial plane. Images were scored by CT attenuation and lumen visibility and compared with theoretical scoring to analyse the effect of multi-segment reconstruction (MSR). An average increase in CT attenuation of 144 {+-} 59 HU and average diminished lumen visibility of 29 {+-} 12% was observed at higher heart rates in both planes. A negative correlation between image quality and heart rate was non-significant for the majority of measurements (P > 0.06). No improvement of image quality was observed in using MSR. In conclusion, in-stent CT attenuation increases and lumen visibility decreases at increasing heart rate. Results obtained with the automated tool show similar behaviour compared with attenuation measurements. Cardiac movement during data acquisition causes approximately twice as much blurring compared with the influence of temporal resolution on image quality. (orig.)

  15. Influence of Simvastatin for In-stent Restenosis Rate and Blood Lipid Level and Inflammation Actor after Coronary Artery Stent Implantation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    To investigate the effect of simvastatin on the probability of restenosis after stent implantation and serum level of lipids as well as high-sensitivity C-reactive protein (hs-CRP) in patients with coronary heart disease (CHD).Methods 118 patients with CHD after stenting therapy were divided into treatment group (n = 62) and control group(n =56) randomly. All patients were treated withaspirin (100 mg/d) and clopidogrel (75 mg/d) while treatment group patients took simvastatin (40 mg qn) additionally. All patients underwent coronary angiography (CAG) to compare the difference of restenosis and the serum level of total cholesterol (TC), low-density lipoprotein cholesterol(LDL-c), high-density lipoprotein cholesterol (HDL-c), triglyceride (TG) as well as hs-CRP after the drug treatment for 6 months. Results The probability of restenosis was significantly lower in the treatment group than that of control group ( P < 0.01 ) and the results were similar between the patients with bare metal stent ( P < 0.01 ) and those with sirolimus-eluting stent ( P<0.01 ). The serum levels of TC (P<0.01 ), LDL-c( P<0.01 ), TG (P<0.05 ) and hsCRP (P<0.01) were obviously lower while the HDL-c (P<0.05 ) level was higher in the treatment group than those of control group. There was no death case. Conclusions Simvastatin could decrease the probability of restenosis significantly after coronary stent implantation with dose of 40 mg/d. It also has good performance on lipids control and lightening inflammatory reactions with its undoubtedly safety.

  16. Improved two-year outcomes after drug-eluting versus bare-metal stent implantation in women and men with large coronary arteries

    DEFF Research Database (Denmark)

    Hansen, K W; Kaiser, C; Hvelplund, A

    2013-01-01

    To investigate the importance of vessel size on outcome differences by comparing the effects of drug-eluting stents (DES) versus bare-metal stents (BMS) in women and men with large coronary vessels.......To investigate the importance of vessel size on outcome differences by comparing the effects of drug-eluting stents (DES) versus bare-metal stents (BMS) in women and men with large coronary vessels....

  17. The Pharmacokinetics of Biolimus A9 after Elution from the Nobori Stent in Patients with Coronary Artery Disease: The NOBORI PK Study

    Science.gov (United States)

    Ostojic, Miodrag; Sagic, Dragan; Jung, Robert; Zhang, Yan-Ling; Nedeljkovic, Milan; Mangovski, Ljupco; Stojkovic, Sinisa; Debeljacki, Dragan; Colic, Mirko; Beleslin, Branko; Milosavljevic, Bratislav; Orlic, Dejan; Topic, Dragan; Karanovic, Nevena; Paunovic, Dragica; Christians, Uwe

    2008-01-01

    Objectives The aim of this study was to assess the pharmacokinetics and tolerability of Biolimus A9 eluted from Nobori coronary stents. Background The release kinetics and pharmacokinetics of drugs delivered via coronary stents have been shown to play an essential role in the efficacy and safety of drug eluting stents. Methods 20 patients with coronary artery disease were treated with single 14 mm (10 patients) or 28 mm long stent (10 patients). Blood samples were drawn at 16 time points to determine the pharmacokinetics of Biolimus A9. At seven time points, complete laboratory and toxicology panels were assessed to screen for potential Biolimus A9 toxicity. The primary endpoint of the study was the systemic blood concentrations of Biolimus A9 after 28 days and 6 months as measured using highly specific and sensitive liquid chromatography- tandem mass spectrometry assay. Results At 28 days, 6 patients (30%) had quantifiable Biolimus A9 concentrations in blood. The highest Biolimus A9 blood concentration measured in any sample was 32.2 pg/mL. The median time to maximum concentration was 2 hours, ranging from 0.05 hours to 3 months. Six months after stent implantation, only 1 of 20 patients had measurable Biolimus A9 concentrations at the lowest level of quantification, while at 9 months no sample had quantifiable Biolimus A9 concentrations. Laboratory and toxicology assessments did not indicate any impact of Biolimus A9 on the evaluated parameters. Conclusion Results of this study suggest that systemic exposure to Biolimus A9 was very low and that Biolimus A9 was well tolerated. PMID:19016466

  18. Long-term effects of biodegradable versus durable polymer-coated sirolimus-eluting stents on coronary arterial wall morphology assessed by virtual histology intravascular ultrasound

    Institute of Scientific and Technical Information of China (English)

    LIU Hui-liang; ZHANG Jiao; JIN Zhi-geng; LUO Jian-ping; MA Dong-xing; YANG Sheng-li; LIU Ying; HAN Wei; JING Li-min; MENG Rong-ying

    2011-01-01

    Background The durable presence of polymer coating on drug-eluting stent (DES) surface may be one of the principal reasons for stent thrombosis. The long-term coronary arterial response to biodegradable polymer-coated sirolimus-eluting stent (BSES) in vivo remained unclear.Methods Forty-one patients were enrolled in this study and virtual histology intravascular ultrasound (VH-IVUS) was performed to assess the native artery vascular responses to BSES compared with durable polymer-coated SES (DSES) during long-term follow-up (median: 8 months). The incidence of necrotic core abutting to the lumen was evaluated at follow-up.Results With similar in-stent late luminal loss (0.15 mm (0.06-0.30 mm) vs. 0.19 mm (0.03-0.30 mm), P=0.772), the overall incidence of necrotic core abutting to the lumen was significantly less in BSES group than in DSES group (44% vs.63%, P <0.05) (proximal 18%, stented site 14% and distal 12% in BSES group, proximal 19%, stented site 28% and distal 16% in DSES group). The DSES-treated segments had a significant higher incidence of necrotic core abutting to the lumen through the stent struts (73% vs. 36%, P <0.01). In addition, more multiple necrotic core abutting to the lumen was observed in DSES group (overall: 63% vs. 36%, P <0.05). Furthermore, when the stented segments with necrotic core abutting to the lumen had been taken into account only, DSES-treated lesions tended to contain more multiple necrotic core abutting to the lumen through the stent struts than BSES-treated lesions (74% vs. 33%), although there was no statistically significant difference between them (P=0.06).Conclusions By VH-IVUS analysis at follow-up, a greater frequency of stable lesion morphometry was shown in lesions treated with BSESs compared with lesions treated with DSESs. The major reason was BSES produced less toxicity to the arterial wall and facilitated neointimal healing as a result of polymer coating on DES surface biodegraded as time went by.

  19. Heparin-Coated Coronary Stents.

    Science.gov (United States)

    van Der Giessen WJ; van Beusekom HM; Larsson; Serruys

    1999-09-01

    The development of the heparin-coated (HC)-stent should be viewed against the backdrop of the early unfavorable results with noncoated stents in the pre-intravascular ultrasound and pre-ticlopidine era. Notwithstanding, results of pilot and randomized trials show a surprisingly low incidence of (sub)acute stent thrombosis under challenging circumstances, such as acute coronary syndromes. Considering the quite low incidence of early complications with noncoated second-generation stents, it may require large trials to prove the clinical efficacy of the heparin- coating against noncoated devices. However, even if the "added value" of the heparin-coating will never be clinically proven, it has helped to enhance the penetration of stent therapy in interventional cardiology. Unlike the situation in 1992, very few cardiologists will now disagree with the statement that stents contribute to the state-of-the-art treatment of patients with angina pectoris or acute myocardial infarction. A preliminary comparison of available trials also suggests that the heparin-coated Palmaz-Schatz stent (Cordis Corp., Waterloo, Belgium) is as effective as the noncoated stent plus abciximab treatment.

  20. One-Year Clinical Outcomes of Ultra Long Apollo Polymer-Based Paclitaxel-Eluting Stents in Patients with Complex, Long Coronary Artery Lesions

    Directory of Open Access Journals (Sweden)

    Mojtaba Salarifar

    2011-09-01

    Full Text Available Background: For all the wealth of research comparing the efficacy of the different types of the drug-eluting stent (DES such as sirolimus- , paclitaxel- , and zotarolimus-eluting stents, there is still a dearth of data on the different brands of each DES type. We aimed to investigate the one-year clinical outcomes, including major adverse cardiac events (MACE, of the use of the ultra long Apollo paclitaxel-eluting stent in patients with long atherosclerotic coronary artery lesions.Methods: According to a retrospective review of the Tehran Heart Center Registry of Interventional Cardiology, a single-center nonrandomized computerized data registry in which all adult patients who undergo single or multi-vessel percutaneous coronary intervention (PCI are enrolled without any specific exclusion criteria, the mixed use of long Apollo paclitaxel-eluting stents and other types of the DES as well as myocardial infarction within forty-eight hours prior to the procedure was excluded. In total, 122 patients were enrolled in the study, and their baseline clinical, angiographic, and procedural characteristics were obtained. In addition, the patients’ follow-up data and, most importantly, MACE during a one-year period after intervention were recorded.Results: The mean follow-up duration was 14.1 ± 3.8 months. The one-year clinical follow-up data were obtained in 95.9 % of all the patients. The incidence of MACE was 5.7% during the entire study period. There was 1 death, which occurred during the initial days after PCI. The incidence of non-fatal myocardial infarction was 2.5% (3 cases, including one patient who underwent target vessel revascularization seven months later. Also, 3 patients with single-vessel disease and in-stent restenosis underwent coronary artery bypass grafting between five to ten months later.Conclusions: Our results showed that the Apollo paclitaxel-eluting stent might be regarded as a safe and effective treatment for long coronary

  1. Successful transradial removal of an inflated coronary stent dislodged from the right coronary ostium.

    Science.gov (United States)

    Porto, Italo; Larosa, Claudio; Rosa, Isabella; Burzotta, Francesco; Trani, Carlo

    2014-01-01

    We describe our solution to the unusual situation of an inflated, large coronary stent (3.5 mm diameter) which became dislodged from the ostium of the right coronary artery after deployment during a transradial procedure. We discussed tips for retrieval from the radial artery while preserving the access for completion of the procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Domestic coronary drug-eluting stents on a new horizon

    Institute of Scientific and Technical Information of China (English)

    SHEN Wei-feng

    2012-01-01

    Supported by growing evidence from randomized clinical trials and observational or registry studies,percutaneous coronary intervention (PCI) with implantation of drug-eluting stents (DES) has become the standard of care for coronary artery disease,because of reduced repeat intervention and improved clinical outcomes in comparison with bare metal stent.1-3Currently,majority of coronary artery disease patients with complicated lesion subsets or clinical conditions can be successfully treated with DES-based PCI with favorable results.4-6 In 2011,around 300000 PCI procedures have been performed in China,with the penetration rate of DES reaching beyond 90% in most of the centers.

  3. Assessment of Coronary Stents by 64-slice Computed Tomography:In-stent Lumen Visibility and Patency

    Institute of Scientific and Technical Information of China (English)

    Ling-yan Kong; Zheng-yu Jin; Shu-yang Zhang; Zhu-hua Zhang; Yi-ning Wang; Lan Song; Xiao-na Zhang; Yun-qing Zhang

    2009-01-01

    Objective To assess lumen visibility of coronary stents by 64-slice computed tomography(CT)coronary angiography,and determine the value of 64-slice CT in non-invasive detecting of in-stent restenosis after coronary artery stent implantation.Methods Totally,60 patients(54 males,aged 57.0±12.7 years)and 105 stents were investigated by 64-slice CT at a mean interval of 20.0±16.6 months after coronary stents implantation.Axial multi-planar reconstruction images of the stents and curved-planar reconstruction images through the median of the stents were reconstructed for evaluating stent image quality on a 5-point scale(1=excellent,5=nonassessable),and stent lumen diameter was detected.Conventional coronary angiography was performed in 18 patients,and 32 stents were evaluated.Results Image quality was good to excellent on average(score 1.71±0.76).Stent image quality score was correlated to heart rate(r=0.281,P<0.01)and stent diameter(r=0.480,P<0.001).All the stents were assessable in lumen visibility with an average visible lumen diameter percentage of 60.7% ±13.6% .Visible lumen diameter percentage was correlated to heart rate(r=-0.193,P<0.05),stent diameter (r=0.403,P<0.001),and stent image quality score(r=-0.500,P<0.001).Visible lumen diameter percentage also varied depending on the stent type.In comparison with the conventional coronary angiography,4 of 6 in-stent stenoses were correctly detected.The sensitivity and specificity for the detection of in-stent stenosis were 66.7% and 84.6% ,respectively.Conclusions Using a 64-slice CT,the stent lumen is partly visible in most of the stents.And 64-slice CT may be useful in the assessment of stent patency.

  4. Estudo comparativo randomizado do implante de Stent de aço inoxidável recoberto por carbono semelhante ao diamante versus não recoberto em pacientes com doença arterial coronariana Randomized comparative study of diamond-like carbon coated stainless steel stent versus uncoated stent implantation in patients with coronary artery disease

    Directory of Open Access Journals (Sweden)

    George César Ximenes Meireles

    2007-04-01

    Full Text Available OBJETIVO: Comparar as taxas de reestenose e de eventos cardíacos maiores em um e seis meses pós-implante de stents recobertos com CSD com os não-recobertos. MÉTODOS: Estudo comparativo, prospectivo, randomizado, de 180 pacientes com diagnóstico de insuficiência coronária, submetidos a implante de stent recoberto com CSD (Phytis® ou stent não-recobertos (Penta®, no período de janeiro de 2003 a julho de 2004. Foram critérios de inclusão: lesão de novo com porcentual de estenose em diâmetro > 50% em artéria coronária com diâmetro de referência > 2,5 mm e OBJECTIVE: To compare restenosis and major cardiac event rates at one and six months after DLC-coated stent implantation with those of uncoated stents. METHODS: Randomized, prospective, comparative study of 180 patients with coronary insufficiency undergoing DLC coated stent (Phytis™ or uncoated stent (Penta™ implantation, from January, 2003 to July, 2004. Inclusion criteria were: de novo lesion with >50% diameter stenosis in a coronary artery with reference diameter > 2,5 mm and < 4 mm, and length < 20 mm. Exclusion criteria were: left main coronary artery and bifurcation lesions, chronic total occlusion, and in-stent restenosis. RESULTS: Clinical and angiographic baseline characteristics of the groups were similar. Procedural success was achieved in 98.9% of the patients in both groups. One cardiac death occurred in each group during hospitalization. Reference diameter and acute gain were greater in the Penta™ group (3.21±0.37 mm vs. 3.34±0.8 mm, p=0.02 and 2.3±0.5 vs. 2.49±0.5, p=0.009, respectively. Angiographic follow-up at six months showed similar rates of restenosis (24.3% vs. 21.8%, p=0.84 and of major cardiac events (16.8% vs. 17.5%, p=1. CONCLUSION: DLC coated stents did not provide better outcomes in relation to uncoated stents.

  5. Clinical Outcome of Double Kissing Crush Versus Provisional Stenting of Coronary Artery Bifurcation Lesions: The 5-Year Follow-Up Results From a Randomized and Multicenter DKCRUSH-II Study (Randomized Study on Double Kissing Crush Technique Versus Provisional Stenting Technique for Coronary Artery Bifurcation Lesions).

    Science.gov (United States)

    Chen, Shao-Liang; Santoso, Teguh; Zhang, Jun-Jie; Ye, Fei; Xu, Ya-Wei; Fu, Qiang; Kan, Jing; Zhang, Feng-Fu; Zhou, Yong; Xie, Du-Jiang; Kwan, Tak W

    2017-02-01

    Provisional stenting is effective for anatomic simple bifurcation lesions. Double kissing crush stenting reduces the 1-year rate of target lesion revascularization. This study aimed to investigate the 5-year clinical results of the DKCRUSH-II study (Randomized Study on Double Kissing Crush Technique Versus Provisional Stenting Technique for Coronary Artery Bifurcation Lesions). A total of 370 patients with coronary bifurcation lesions who were randomly assigned to either the double kissing crush or provisional stenting group in the DKCRUSH-II study were followed for 5 years. The primary end point was the occurrence of a major adverse cardiac event at 5 years. Patients were classified by simple and complex bifurcation lesions according to the DEFINITION criteria (Definitions and Impact of Complex Bifurcation Lesions on Clinical Outcomes After Percutaneous Coronary Intervention Using Drug-Eluting Stents). At 5 years, the major adverse cardiac event rate (23.8%) in the provisional stenting group was insignificantly different to that of the double kissing group (15.7%; P=0.051). However, the difference in the target lesion revascularization rate between 2 groups was sustained through the 5-year follow-up (16.2% versus 8.6%; P=0.027). The definite and probable stent thrombosis rate was 2.7% in each group (P=1.0). Complex bifurcation was associated with a higher rate of target lesion revascularization (21.6%) at 5 years compared with 11.1% in patients with a simple bifurcation (P=0.037), with an extremely high rate in the provisional stenting group (36.8% versus 12.5%, P=0.005) mainly because of final kissing balloon inflation (19.4% versus 5.2%; P=0.036). The double kissing crush stenting technique for coronary bifurcation lesions is associated with a lower rate of target lesion revascularization. The optimal stenting approach based on the lesions' complexity may improve the revascularization for patients with complex bifurcations. URL: http://www.chictr.org. Unique

  6. Emergency coronary stenting with the Palmaz-Schatz stent for failed transluminal coronary angioplasty: results of a learning phase.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J; van der Wieken, R; Suwarganda, J

    1993-07-01

    This study describes initial results of Palmaz-Schatz stent implantation in our department to restore and maintain vessel patency in 52 patients with obstructive dissection, defined as an intraluminal filling defect with coronary flow impairment after percutaneous transluminal coronary angioplasty (PTCA). The majority of patients (62%) underwent PTCA for unstable angina (n = 28), defined as angina at rest with documented ST segment changes resistant to nitrates, or acute myocardial infarction (n = 4). In six patients (11%) the stent could not be delivered. Seven of the remaining 46 patients (15%) had coronary artery bypass surgery performed because of increased risk for subacute stent occlusion, residual thrombosis, residual obstruction near the stent, coronary artery diameter less than 3.0 mm, or multiple and overlapping stents. One patient (3%) died in hospital from intracranial bleeding. Nine patients (23%) had subacute stent occlusion, retrospectively unpredictable in four patients. Nine of 29 patients (29%) with an uncomplicated clinical course after stenting had angiographic restenosis at a mean follow-up of 6.0 +/- 1.4 months (range 12 days to 8.3 months). Two patients (7%) died 3 months after successful stenting: one patient because of stent thrombosis after stopping warfarin before an abdominal operation and one patient after acute vascular surgery for late traumatic groin bleeding. Of the 39 medically treated patients with a stent, three (8%) had major bleeding complications. It is concluded that stent implantation is feasible in most patients with obstructive dissection after PTCA. After successful stent delivery, coronary flow is temporarily restored.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Coronary anomaly: the single coronary artery

    Institute of Scientific and Technical Information of China (English)

    QIN Xu-guang; XIONG Wei-guo; LU Chun-peng; GONG Cheng-jie; SHANG Li-hua

    2010-01-01

    @@ Single coronary artery (SCA), defined as an artery that arises from the arterial trunk and nourishes the entire myocardium, is rare. We report two cases of SCA, one is the right coronary artery (RCA) originating from the middle of left descending artery (LAD), and the other is the left main coronary artery (LMCA) arising from the proximal right coronary artery.

  8. Bioresorbable scaffolds in the treatment of coronary artery disease

    NARCIS (Netherlands)

    Y. Zhang (Yaojun); C.V. Bourantas (Christos); V. Farooq (Vasim); T. Muramatsu (Takashi); R. Diletti (Roberto); Y. Onuma (Yoshinobu); H.M. Garcia-Garcia (Hector); P.W.J.C. Serruys (Patrick)

    2013-01-01

    textabstractDrug-eluting stents have reduced the risk of in-stent restenosis and have broadened the application in percutaneous coronary intervention in coronary artery disease. However, the concept of using a permanent metallic endovascular device to restore the patency of a stenotic artery has inh

  9. Grade III Coronary Artery Perforation Following PCI and Unusual Stent Graft Delivery System

    Directory of Open Access Journals (Sweden)

    Sreckovic Miodrag

    2014-06-01

    Full Text Available Koronarne perforacije su retke ali izuzetno neugodne komlikacije perkutanih intervencija. Perforacije koronarnh arterija trećeg stepena po Elisu predstvaljaju najozbiljniju formu perforacija i zahtevaju hitno zbrinjavanje. Često je neophodno uraditi perikardiocentezu i primeniti brojne interventne tehnike kako bismo rešili perforaciju. Stentovi prekriveni politetrafluoroetilenom(PTFE postali su jedno od najčešće korišćenih perkutanih rešenja, ali su njihove mane visoki profil i slaba fleksibilnost. U našem slučaju, pokušali smo da poboljšamo plasiranje PTFE stenta montiranjem na metalni stent, koji smo iskoristili kao nosač.

  10. Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model.

    Science.gov (United States)

    Hikichi, Yutaka; Umezu, Mitsuo; Node, Koichi; Iwasaki, Kiyotaka

    2017-01-01

    Stent struts protruding into ostial side branch called "jailed strut" at bifurcation lesions is a likely cause of thrombus formation. We aimed to investigate the influences of multiple kissing balloon inflation (KBI) for stent expansion, and stent platform design, respectively, on the reduction of incomplete stent apposition area (ISA area) caused by jailed struts at a side-branch ostium, using a three-dimensional elastic left main (LM) bifurcated coronary artery model. The referenced LM bifurcation angle data of 209 patients were stratified by tertiles focusing on the angle between the LM trunk (LMT) and left anterior descending artery (LAD). A bifurcation model was fabricated with angles of 129°, 122.2°, and 76.4° for LMT-LAD, LMT-left circumflex (LCx), and LAD-LCx, respectively, and with diameters of 5, 3.75, and 3.5 mm for LMT, LAD, and LCx, respectively; these diameters fulfill Murray's law. A 75 % stenosis was included along the LMT. One-time and three-time KBIs were conducted using two-link Nobori and three-link Xience Xpedition (n = 6 each). The ISA area was quantified using micro-CT. Three-time KBI was effective in reducing the ISA area compared with one-time KBI for both the Nobori (p = 0.05) and Xience Xpedition (p = 0.07). The ISA area was smaller in the Nobori than in the Xience Xpedition, both in one-time and three-time KBI (one-time KBI: p = 0.003; three-time KBI: p = 0.001). Our findings of this study on reducing the ISA area by focusing on an interventional technique and stent design may help to improve coronary bifurcation intervention for a possibly better long-term clinical outcome.

  11. Biocompatibility of coronary stent materials: effect of electrochemical polishing

    Energy Technology Data Exchange (ETDEWEB)

    Scheerder, I. de [University Hospital Leuven (Belgium). Dept. of Cardiology; Sohier, J.; Froyen, L.; Humbeeck, J. van [Louvain Univ. (Belgium). Dept. of Metallurgy and Materials Engineering; Verbeken, E. [University Hospital Leuven (Belgium). Dept. of Pathology

    2001-02-01

    Percutaneous Transluminal Coronary Revascularization (PTCR) is now a widely accepted treatment modality for atherosclerotic coronary artery disease. Current multicenter randomized trials comparing PTCR with the more invasive Coronary Artery Bypass Grafting could not show long-term significant survival differences. During the last two decades progress has been made to further optimize PTCR. The most logic approach to treat atherosclerotic coronary narrowings is to remove the atherosclerotic material using especially developed devices. Several trials, however, could not show a significant beneficial outcome after use of these devices compared to plain old balloon angioplasty. Another approach was to implant a coronary prothesis (stent), scaffolding the diseased coronary artery after PTCA. This approach resulted in a decreased restenosis rate at follow-up. The beneficial effects of stenting, however, was not found to be related to the inhibition of the neointimal cellular proliferation after vascular injury, but simply to be the mechanical result of overstretching of the treated vessel segment. The most important remaining clinical problem after stenting remains the neointimal hyperplasia within the stent, resulting in a significant stent narrowing in 13 to 30% of patients. Further efforts to improve the clinical results of coronary stenting should focus on the reduction of this neointimal hyperplasia. Neointimal hyperplasia after stent implantation results from (1) a healting response to the injury caused by the stent implantation and (2) a foreign body response to the stent itself. Factors that seem to influence the neointimal hyperplastic response are genetic, local disease related, stent delivery related and stent related factors. Biocompatibilisation of coronary stents by looking for more biocompatible metal alloys, optimized surface characteristics and optimized stent designs should result in a better late patency. Furthermore drug eluting and radioactive stents

  12. Maximizing benefit of drug-eluting stent by direct coronary stenting because of further reduction of inflammatory response

    Institute of Scientific and Technical Information of China (English)

    LI Jian-jun; GAO Run-lin

    2009-01-01

    @@ Coronary stents have been used as standard mechanical devices for percutaneous coronary intervention (PCI) in patients with coronary artery disease (CAD).1-3 They provide vessel wall scaffolding and prevent early elastic recoil and restenosis, which are major limitations of balloon angioplasty.4,5 Consequently, coronary stenting has a higher successful rate of PCI and improves the clinical outcome of the patients with CAD.6

  13. [Safety of magnetic resonance imaging after coronary stenting].

    Science.gov (United States)

    Sinitsyn, V E; Stukalova, O V; Kupriianova, O M; Ternovoĭ, S K

    2007-01-01

    Magnetic resonance imaging (MRI) is contraindicated to some patients with certain types of metallic devices and implants (e.g. cerebral surgical clips, defibrillators). There are some controversies concerning safety of MRI in patients with metallic coronary stents in cases when MRI examination is performed earlier then one month after stent implantation. Analysis of published data has shown that MRI performed with systems having field strength up to 3 Tesla does not cause migration and heating of both bare and coated stent and is not associated with increased risk of coronary artery thrombosis. MRI can be performed safely in first days after coronary stent implantation. Small local artifacts on MRI images do not influence interpretation of the data (except for cases of coronary magnetic resonance angiography).

  14. Nine-month Angiographic and Two-year Clinical Follow-up of Novel Biodegradable-polymer Arsenic Trioxide-eluting Stent Versus Durable-polymer Sirolimus-eluting Stent For Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Li Shen

    2015-01-01

    Full Text Available Background: Despite great reduction of in-stent restenosis, first-generation drug-eluting stents (DESs have increased the risk of late stent thrombosis due to delayed endothelialization. Arsenic trioxide, a natural substance that could inhibit cell proliferation and induce cell apoptosis, seems to be a promising surrogate of sirolimus to improve DES performance. This randomized controlled trial was to evaluate the efficacy and safety of a novel arsenic trioxide-eluting stent (AES, compared with traditional sirolimus-eluting stent (SES. Methods: Patients with symptoms of angina pectoris were enrolled and randomized to AES or SES group. The primary endpoint was target vessel failure (TVF, and the second endpoint includes rates of all-cause death, cardiac death or myocardial infarction, target lesion revascularization (TLR by telephone visit and late luminal loss (LLL at 9-month by angiographic follow-up. Results: From July 2007 to 2009, 212 patients were enrolled and randomized 1:1 to receive either AES or SES. At 2 years of follow-up, TVF rate was similar between AES and SES group (6.67% vs. 5.83%, P = 0.980. Frequency of all-cause death was significantly lower in AES group (0 vs. 4.85%, P = 0.028. There was no significant difference between AES and SES in frequency of TLR and in-stent restenosis, but greater in-stent LLL was observed for AES group (0.29 ± 0.52 mm vs. 0.10 ± 0.25 mm, P = 0.008. Conclusions: After 2 years of follow-up, AES demonstrated comparable efficacy and safety to SES for the treatment of de novo coronary artery lesions.

  15. Recent developments in drug-eluting coronary stents.

    Science.gov (United States)

    Yildiz, Mustafa; Yildiz, Banu Sahin; Gursoy, Mustafa Ozan; Akin, Ibrahim

    2014-01-01

    The interventional treatment of coronary artery disease was introduced in 1970`s by Andreas Grüntzig. The initial treatment strategy with plain old balloon angioplasty (POBA) was associated with high restenosis rates. The introduction of coronary stents, especially drug-eluting stents (DES) in 2002 has improved the results by lowering the rate of in-stent restenosis from 20-40% in the era of bare-metal stent (BMS) to 6-8%. However, in 2006 with the observation of late stent thrombosis the reputations of DES have decreased. However, improvements in stent design especially antiproliferative agents, polymeric agents as well as stent platforms improved newer generation DES. In controlled trials as well as registries the use of second-generation DES as compared to bare-metal stents (BMS) was associated with better clinical and angiographic results. A further development of these stents with use of biodegradable polymers, polymer-free stents, and biodegradable stents on the basis of poly L-lactide (PLLA) or magnesium resulted in third-generation DES and has been evaluated in preclinical and first clinical trials. However, to date, there is a lack of data comparing these third-generation DES with first- and second-generatrion DES in a large scale.

  16. Clinical utility of platinum chromium bare-metal stents in coronary heart disease

    Directory of Open Access Journals (Sweden)

    Jorge C

    2015-08-01

    Full Text Available Claudia Jorge,1 Christophe Dubois1,2 1Department of Cardiovascular Medicine, University Hospitals Leuven, 2Department of Cardiovascular Sciences, Katholieke Universiteit Leuven, Leuven, Belgium Abstract: Coronary stents represent a key development for the treatment of obstructive coronary artery disease since the introduction of percutaneous coronary intervention. While drug-eluting stents gained wide acceptance in contemporary percutaneous coronary intervention practice, further developments in bare-metal stents remain crucial for patients who are not candidates for drug-eluting stents, or to improve metallic platforms for drug elution. Initially, stent platforms used biologically inert stainless steel, restricting stent performance due to limitations in flexibility and strut thickness. Later, cobalt chromium stent alloys outperformed steel as the material of choice for stents, allowing latest generation stents to be designed with significantly thinner struts, while maintaining corrosion resistance and radial strength. Most recently, the introduction of the platinum chromium alloy refined stent architecture with thin struts, high radial strength, conformability, and improved radiopacity. This review will provide an overview of the novel platinum chromium bare-metal stent platforms available for coronary intervention. Mechanical properties, clinical utility, and device limitations will be summarized and put into perspective. Keywords: bare metal stent, coronary stent alloys, coronary artery disease

  17. Expression and function of calcium-activated potassium channels following in-stent restenosis in a porcine coronary artery model

    Directory of Open Access Journals (Sweden)

    Mais F. Absi

    2012-04-01

    Functional analysis using 1-EBIO and Bradykinin produced hyperpolarization of neointimal but not medial myocytes, which indicated the expression of functional endothelial SK3 and IKCa in the former and not in the latter. The expression of IKCa and SK3 within the neointimal layer suggested that some degree of recovery of both endothelial as well as smooth muscle regeneration had occurred. Future development of selective modulators of IKCa and SK3 channels may decrease the progression of ISR and improve coronary vascular function after stent placement, and is an area for future investigation.

  18. Multiobjective design optimisation of coronary stents.

    Science.gov (United States)

    Pant, Sanjay; Limbert, Georges; Curzen, Nick P; Bressloff, Neil W

    2011-11-01

    We present here a multi-objective and multi-disciplinary coronary stent design optimization paradigm. Coronary stents are tubular, often mesh-like, structures which are deployed in diseased (stenosed) artery segments to provide a scaffolding feature that compresses atheromatus plaque, hence restoring luminal area and maintaining vessel patency. A three variable geometry parameterisation of a CYPHER (Cordis Corporation, Johnson & Johnson co.) type stent is proposed to explore the functionality of a sequence of circumferential rings connected by 'n' shaped links. The performance of each design is measured by six figures of merit (objectives/metrics) representing (i) acute recoil, (ii) tissue stresses, (iii) haemodynamic disturbance, (iv) drug delivery, (v) uniformity of drug distribution, and (vi) flexibility. These metrics are obtained from computational simulations of (i) structural deformation through balloon inflated expansion of a stent into contact with a stenosed vessel, (ii) pulsatile flow over the deformed stent embedded in the vessel wall, (iii) steady-state drug distribution into the tissue, and (iv) flexibility of a stent in response to an applied moment. Design improvement is obtained by a multi-objective surrogate modelling approach using a non-dominated sorting genetic algorithm (NSGA-II) to search for an optimal family of designs. A number of trade-offs between the different objectives are identified. In particular a conflict between pairs of the following objectives are shown -- (a) volume average stress vs. recoil, (b) volume average drug vs. volume average stress, (c) flexibility vs. volume average stress, (d) flexibility vs. haemodynamic disturbance, (e) volume average drug vs. haemodynamic disturbance, and (f) uniformity of drug vs. volume average stress. Different paradigms to choose the optimal designs from the obtained Pareto fronts are presented and under each such paradigm, the optimal designs and there relative positions with respect to a

  19. Clinical experience in coronary stenting with the Vivant Z Stent.

    Science.gov (United States)

    Chee, K H; Siaw, F S; Chan, C G; Chong, W P; Imran, Z A; Haizal, H K; Azman, W; Tan, K H

    2005-06-01

    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.

  20. Late thrombosis of coronary bare-metal stent: Case report

    Directory of Open Access Journals (Sweden)

    Apostolović Svetlana

    2006-01-01

    Full Text Available Stent thrombosis remains the primary cause of death after percutaneous coronary interventions (PCI. Despite modern concepts of PCI, stent thrombosis occurs in 0.5% -2% of elective procedures and even 6% of patients with the acute coronary syndrome (ACS. Stent thrombosis most often develops within the first 48 hours after the PCI, and rarely after a week of stent implantation. Angiographically documented late (>6 months thrombosis of coronary bare-metal stent (BMS is rare, because the stent endothelialization is considered to be completed after four weeks of the intervention. Our patient is a 41 year old male and he had BMS thrombosis 345 days after the implantation, which was clinically manifested as an acute myocardial infarction in the inferoposterolateral localization. Stent Clinical Centre of Serbia, Belgrade thrombosis occurred despite a long term dual antiplatelet therapy and control of known risk factors. Thrombolytic therapy (Streptokinase in a dose of 1 500 000 IU was not successful in reopening the occluded vessel, so the flow through the coronary artery was achieved by rescue balloon angioplasty, followed by implantation of drug eluting stent in order to prevent restenosis.

  1. New Technologies in Coronary Artery Surgery

    Directory of Open Access Journals (Sweden)

    David Taggart

    2013-07-01

    Full Text Available Coronary artery disease remains the leading cause of death in developed countries. Major recent studies such as SYNTAX and FREEDOM have confirmed that coronary artery bypass grafting (CABG remains the gold standard treatment in terms of survival and freedom from myocardial infarction and the need for repeat revascularization. The current review explores the use of new technologies and future directions in coronary artery surgery, through 1 stressing the importance of multiple arterial conduits and especially the use of bilateral mammary artery; 2 discussing the advantages and disadvantages of off-pump coronary artery bypass; 3 presenting additional techniques, e.g. minimally invasive direct coronary artery bypass grafting, hybrid, and robotic-assisted CABG; and, finally, 4 debating a novel external stenting technique for saphenous vein grafts.

  2. CT virtual endoscopy and 3D stereoscopic visualisation in the evaluation of coronary stenting.

    Science.gov (United States)

    Sun, Z; Lawrence-Brown

    2009-10-01

    The aim of this case report is to present the additional value provided by CT virtual endoscopy and 3D stereoscopic visualisation when compared with 2D visualisations in the assessment of coronary stenting. A 64-year old patient was treated with left coronary stenting 8 years ago and recently followed up with multidetector row CT angiography. An in-stent restenosis of the left coronary artery was suspected based on 2D axial and multiplanar reformatted images. 3D virtual endoscopy was generated to demonstrate the smooth intraluminal surface of coronary artery wall, and there was no evidence of restenosis or intraluminal irregularity. Virtual fly-through of the coronary artery was produced to examine the entire length of the coronary artery with the aim of demonstrating the intraluminal changes following placement of the coronary stent. In addition, stereoscopic views were generated to show the relationship between coronary artery branches and the coronary stent. In comparison with traditional 2D visualisations, virtual endoscopy was useful for assessment of the intraluminal appearance of the coronary artery wall following coronary stent implantation, while stereoscopic visualisation improved observers' understanding of the complex cardiac structures. Thus, both methods could be used as a complementary tool in cardiac imaging.

  3. Direct coronary stent implantation: safety, feasibility, and predictors of success of the strategy of direct coronary stent implantation.

    Science.gov (United States)

    Laarman, G; Muthusamy, T S; Swart, H; Westendorp, I; Kiemeneij, F; Slagboom, T; van der Wieken, R

    2001-04-01

    , and 70.2 +/- 11.2 vs. 73.2 +/- 11.2, P = NS). Stent loss occurred in five (2.0%) cases, with successful retrieval in four. One stent was lost permanently in a small branch of the radial artery. Post-percutaneous coronary intervention (post-PCI) myocardial infarction occurred in four (1.6%) patients. There were no other in-hospital events. Six-month-follow up information was obtained in 99% of patients. Subacute stent thrombosis was noted in four (1.6%) cases. Target vessel-related myocardial infarction rate was 3.2%, of which half was caused by subacute stent thrombosis. The overall reintervention rate (coronary artery bypass grafting or PCI) was 9.7%. Target lesion revascularization by PCI occurred in only 4.0%. At 6 months, overall mortality was 2.0%, of which 1.2% was due to coronary events. Direct stent implantation is safe and feasible in the majority of cases with low rate of complications. Unfavorable factors include circumflex lesion, more complex lesion morphology, and increasing length of stent. Severity of stenosis does not appear to be of predictive value. Long-term outcome is favorable with a low target lesion revascularization rate.

  4. Incidence and predictors of coronary stent thrombosis

    DEFF Research Database (Denmark)

    D'Ascenzo, Fabrizio; Bollati, Mario; Clementi, Fabrizio

    2013-01-01

    Stent thrombosis remains among the most feared complications of percutaneous coronary intervention (PCI) with stenting. However, data on its incidence and predictors are sparse and conflicting. We thus aimed to perform a collaborative systematic review on incidence and predictors of stent...

  5. 老年冠心病小血管置入EXCEL支架的安全性与有效性%Outcomes of percutaneous coronary intervention with EXCEL stents for elderly patients with small vessel coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    张华; 孙书红; 张磊; 杨星昌; 马兰香; 惠增骞; 丁守良; 赵妮; 韩雅玲

    2012-01-01

    Objective To assess the efficacy and safety of percutaneous coronary intervention with EXCEL stents for elderly patients with small vessel coronary artery disease. Methods Patients were assigned into small stent group( 0. 05 ). The small stent group had higher stent thrombosisrate than the large stent group ( P < 0. 05 ). Conclusions This study demonstrates not only the clinical safety and efficacy of biodegradable polymer based sirolimus - eluting stents. In elderly patients with small vessel coronary artery disease, but also a higher stent thrombosis rate in the long - term outcome.%目的 观察老年冠心病患者小血管置入国产EXCEL支架的安全性与有效性.方法 本研究对老年冠心病患者单纯置入小血管支架(支架直径<3.0 mm,297例)和单纯置入大血管支架(直径≥3.0 mm,405例)进行对比分析,术后6、12、18个月进行随访,观察临床不良事件(major adverse cardiac events,MACE)发生情况及血栓发生率.结果 6~18个月时两组间MACE事件、靶病变血运重建(target lesion revascularization,TLR)、心源性病死率差异无统计学意义,但非致命性急性心肌梗死(myocardial infarction,MI)及累计血栓事件老年小血管支架组较大血管组增加(P<0.05).结论 老年冠心病患者小血管内置入国产EXCEL比同龄大血管冠心病患者血栓累计发生率高.

  6. Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT.

    Science.gov (United States)

    Maintz, David; Burg, Matthias C; Seifarth, Harald; Bunck, Alexander C; Ozgün, Murat; Fischbach, Roman; Jürgens, Kai Uwe; Heindel, Walter

    2009-01-01

    The aim of this study was to test a large sample of the latest coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in dual-source multidetector row CT (DSCT) in vitro and to provide a CT catalogue of currently used coronary artery stents. Twenty-nine different coronary artery stents (19 steel, 6 cobalt-chromium, 2 tantalum, 1 iron, 1 magnesium) were examined in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70 HU). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 400 mAs, 120 kV, rotation time 0.33 s. Image reconstructions were obtained with four different convolution kernels (soft, medium-soft, standard high-resolution, stent-dedicated). To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density, and noise were measured. The stent-dedicated kernel offered best average lumen visualization (54 +/- 8.3%) and most realistic lumen attenuation (222 +/- 44 HU) at the expense of increased noise (23.9 +/- 1.9 HU) compared with standard CTA protocols (p magnesium stent showed the least artifacts with a lumen visibility of 90%. The majority of stents (79%) exhibited a lumen visibility of 50-59%. Less than half of the stent lumen was visible in only six stents. Stent lumen visibility largely varies depending on the stent type. Magnesium is by far more favorable a stent material with regard to CT imaging when compared with the more common materials steel, cobalt-chromium, or tantalum. The magnesium stent exhibits a lumen visibility of 90%, whereas the majority of the other stents exhibit a lumen visibility of 50-59%.

  7. Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Maintz, David; Burg, Matthias C.; Seifarth, Harald; Bunck, Alexander C.; Oezguen, Murat; Juergens, Kai Uwe; Heindel, Walter [University of Muenster, Department of Clinical Radiology, Muenster (Germany); Fischbach, Roman [University of Muenster, Department of Clinical Radiology, Muenster (Germany); Asklepios Klinikum Altona, Department of Radiology and Nuclear Medicine, Hamburg (Germany)

    2009-01-15

    The aim of this study was to test a large sample of the latest coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in dual-source multidetector row CT (DSCT) in vitro and to provide a CT catalogue of currently used coronary artery stents. Twenty-nine different coronary artery stents (19 steel, 6 cobalt-chromium, 2 tantalum, 1 iron, 1 magnesium) were examined in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70 HU). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 400 mAs, 120 kV, rotation time 0.33 s. Image reconstructions were obtained with four different convolution kernels (soft, medium-soft, standard high-resolution, stent-dedicated). To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density, and noise were measured. The stent-dedicated kernel offered best average lumen visualization (54{+-}8.3%) and most realistic lumen attenuation (222{+-}44 HU) at the expense of increased noise (23.9{+-}1.9 HU) compared with standard CTA protocols (p<0.001 for all). The magnesium stent showed the least artifacts with a lumen visibility of 90%. The majority of stents (79%) exhibited a lumen visibility of 50-59%. Less than half of the stent lumen was visible in only six stents. Stent lumen visibility largely varies depending on the stent type. Magnesium is by far more favorable a stent material with regard to CT imaging when compared with the more common materials steel, cobalt-chromium, or tantalum. The magnesium stent exhibits a lumen visibility of 90%, whereas the majority of the other stents exhibit a lumen visibility of 50-59%. (orig.)

  8. Advances in nanotechnology for the management of coronary artery disease.

    Science.gov (United States)

    Rhee, June-Wha; Wu, Joseph C

    2013-02-01

    Nanotechnology holds tremendous potential to advance the current treatment of coronary artery disease. Nanotechnology may assist medical therapies by providing a safe and efficacious delivery platform for a variety of drugs aimed at modulating lipid disorders, decreasing inflammation and angiogenesis within atherosclerotic plaques, and preventing plaque thrombosis. Nanotechnology may improve coronary stent applications by promoting endothelial recovery on a stent surface utilizing bio-mimetic nanofibrous scaffolds, and also by preventing in-stent restenosis using nanoparticle-based delivery of drugs that are decoupled from stents. Additionally, nanotechnology may enhance tissue-engineered graft materials for application in coronary artery bypass grafting by facilitating cellular infiltration and remodeling of a graft matrix.

  9. Comparison of drug eluting stent implantation with coronary artery bypass surgery in the treatment of patients with chronic total occlusion and multiple vessel disease

    Institute of Scientific and Technical Information of China (English)

    LIU Wei; ZHU Xiao-Ling; MA Chang-sheng; KANG Jun-ping; DU Xin; CHEN Fang; ZHOU Yu-jie; L(U) Shu-zheng; HUANG Fang-jiong; GU Cheng-xiong

    2011-01-01

    Background In patients with chronic total occlusion (CTO) and multivessel coronary artery disease, the comparison of surgical and the percutaneous revascularization strategies has rarely been conducted. The aim of this study was to compare long term clinical outcomes of drug eluting stent (DES) implantation with coronary artery bypass surgery (CABG)in the patients with CTO and multivessel disease.Methods From a prospective registry of 6000 patients in our institution, we included patients with CTO and multivessel coronary artery disease who underwent either CABG (n=679) or DES (n=267) treatment. Their propensity risk score was used for adjusting baseline differences.Results At a median follow-up of three years, propensity score adjusted Cox regression analysis showed that the rate of major adverse cardiac cerebrovascular events (MACCE) was lower in CABG group (12.7% vs. 24.3%, hazard ratio (HR) 1.969, 95% Cl 1.219-3.179, P=0.006) mainly due to lower rate of target vessel revascularization in CABG group than in DES group (3.1% vs. 17.2%, HR 16.14, 95% CI 5.739-45.391, P <0.001). The incidence of cardiac death or myocardial infarction (composite end point) was not significantly different between these two groups. On multivariate analysis, the significant predictors of MACCE were only the type of revascularization. Age, left ventricular ejection fraction (LVEF), and complete revascularization were identified as significant predictors of composite end points.Conclusions Our study shows that in patients with CTO and multivessel coronary disease, DES can offer comparable long term outcomes in cardiac death and myocardial infraction free survival in comparison with CABG. However, there is an increased rate of MACCE which results from more repeat revascularizations. Obtaining a complete revascularization is crucial for decreasing adverse cardiac events.

  10. 冠状动脉支架植入患者的心理评估%Mental Health Assessment of Coronary Artery Stent Implantation

    Institute of Scientific and Technical Information of China (English)

    董效信; 任晓敏; 董雅妮

    2011-01-01

    Objective To investigate the mental health status of patients with coronary artery stent implantation. Methods Symptom Checklist (SCL-90) was used to evaluate the mental health conditions of 218 patients after coronary artery stent implantation with man-machine conversation and computer evaluation. Results It was found that 48 cases in excellent mental health, accounting for 22.02%; 56 cases in good mental health condition, accounting for 25.69%; 82 cases in normal mental health condition, accounting for 37.61%; and 32 cases in poor mental health, accounting for 14.68%. In addition to the interpersonal factor, hostility and psychosis factors, the other six factors' overall average score was more than 2. More than 50% of the staff scored greater than 3, and their average positive factors were greater than 43 items in somatization, depression, anxiety and fear. Conclusion The patients after coronary artery stent implantation suffered from many psychological problems.%目的 调查冠状动脉支架植入患者的心理健康状况.方法 采用症状自评量表(SCL-90)对218例冠状动脉支架植入患者进行心理健康状况评估.结果 症状自评量表评定发现,患者心理健康状况好48例(22.02%),良好56例(25.69%),一般82例(37.61%),较差32例(14.68%).因子评分除人际、敌对和精神病性外,其余6项因子总平均分>2分.在躯体化、忧郁、焦虑和恐怖因子评分中有50%以上的人员因子分>3,阳性项目平均数>43项.结论 冠状动脉支架植入患者存在许多心理问题.

  11. Coronary Artery Bypass Surgery

    Science.gov (United States)

    In coronary artery disease (CAD), the arteries that supply blood and oxygen to your heart muscle grow hardened and narrowed. You may try ... these treatments don't help, you may need coronary artery bypass surgery. The surgery creates a new ...

  12. High field MR imaging: magnetic field interactions of aneurysm clips, coronary artery stents and iliac artery stents with a 3.0 Tesla MR system; Hochfeld-Magnetresonanztomographie: Magnetische Anziehungs- und Rotationskraefte auf metallische Implantate bei 3,0 T

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T.; Schmiedel, A.; Hackenbroch, M.; Hofer, U.; Urbach, H.; Traeber, F.; Schild, H. [Radiologische Univ. Bonn (Germany); Maintz, D. [Radiologische Univ. Muenster (Germany); Pavlidis, C. [Klinik fuer Neurochirurgie, Univ. Bonn (Germany); Hoeher, M. [Medizinische Univ. II Ulm (Germany)

    2004-05-01

    Purpose: to evaluate magnetic field interactions of commonly used biomedical implants at 3.0 tesla. Materials and methods: fourteen aneurysm clips designed for permanent placement in intracranial aneurysms, 19 coronary artery stents and 20 iliac artery stents were evaluated in an actively shielded compact 3.0 T MR system (Intera, Philips Medical Systems, Best, the Netherlands, length of magnet 1.57 m). The magnetic deflection forces (translational movement) were evaluated as follows: the implants were suspended by a fine string and placed in the magnet bore at the location of the maximum magnetic field gradient. The translational forces F{sub z} were calculated from the measured angle of deflection from the vertical axis. The magnetic field-induced torque (rotational forces) was evaluated as follows: each implant was placed in the center of the magnetic bore parallel to the static magnetic field B0 (position 0 ). Any possible displacement of the implant was noted on a millimeter scale and any torque qualitatively evaluated using a 5 point grading scale (0: no torque; + 4: very strong torque). The implant was turned in steps of 45 , and the procedure was repeated to encompass a full 360 rotation. Results: in 52 of the 53 devices tested, the deflection force (deflection angle: range 0-21 , translational force: range 0-3.8 mN) was less than the gravitational force (i.e., the implant's weight). These devices (n = 52/53) did not show any alignment to or rotation in the magnetic field at any of the various 45 -increment positions corresponding to a qualitative torque evaluation of grade 0/4. One device (n = 1/53), an iliac artery stent made of stainless steel (Zenith, Cook, Moenchengladbach, BRD), was found to have deflection forces (deflection angle 88 translational force 299 mN) greatly exceeding the gravitational force as well as a pronounced torque (grade 4/4). (orig.) [German] Ziel: Die In-vitro-Evaluierung verschiedener biomedizinischer Implantate hinsichtlich

  13. Systematic preoperative coronary angiography and stenting improves postoperative results of carotid endarterectomy in patients with asymptomatic coronary artery disease: a randomised controlled trial.

    Science.gov (United States)

    Illuminati, G; Ricco, J-B; Greco, C; Mangieri, E; Calio', F; Ceccanei, G; Pacilè, M A; Schiariti, M; Tanzilli, G; Barillà, F; Paravati, V; Mazzesi, G; Miraldi, F; Tritapepe, L

    2010-02-01

    To evaluate the usefulness of systematic coronary angiography followed, if needed, by coronary artery angioplasty (percutaneous coronary intervention (PCI)) on the incidence of cardiac ischaemic events after carotid endarterectomy (CEA) in patients without evidence of coronary artery disease (CAD). From January 2005 to December 2008, 426 patients, candidates for CEA, with no history of CAD and with normal cardiac ultrasound and electrocardiography (ECG), were randomised into two groups. In group A (n=216) all the patients had coronary angiography performed before CEA. In group B, all the patients had CEA without previous coronary angiography. In group A, 66 patients presenting significant coronary artery lesions at angiography received PCI before CEA. They subsequently underwent surgery under aspirin (100 mg day(-1)) and clopidogrel (75 mg day(-1)). CEA was performed within a median delay of 4 days after PCI (range: 1-8 days). Risk factors, indications for CEA and surgical techniques were comparable in both groups (p>0.05). The primary combined endpoint of the study was the incidence of postoperative myocardial ischaemic events combined with the incidence of complications of coronary angiography. Secondary endpoints were death and stroke rates after CEA and incidence of cervical haematoma. Postoperative mortality was 0% in group A and 0.9% in group B (p=0.24). One postoperative stroke (0.5%) occurred in group A, and two (0.9%) in group B (p=0.62). No postoperative myocardial event was observed in group A, whereas nine ischaemic events were observed in group B, including one fatal myocardial infarction (p=0.01). Binary logistic regression analysis demonstrated that preoperative coronary angiography was the only independent variable that predicted the occurrence of postoperative coronary ischaemia after CEA. The odds ratio for coronary angiography (group A) indicated that when holding all other variables constant, a patient having preoperative coronary angiography

  14. Acute clinical and angiographic results with the new AVE Micro coronary stent in bailout management.

    NARCIS (Netherlands)

    Y. Ozaki (Yukio); D.T.J. Keane (David); P.N. Ruygrok (Peter); S. Stertzer (Simon); P.W.J.C. Serruys (Patrick); P.J. de Feyter (Pim)

    1995-01-01

    textabstractTo determine the feasibility and safety of development of this new stent, we deployed 28 AVE Micro stents in 23 native coronary artery lesions in 20 patients who developed acute or threatened closure after balloon angioplasty (BA). Ten stents were deployed in the left anterior descending

  15. Coronary Artery Disease

    Science.gov (United States)

    Coronary artery disease (CAD) is the most common type of heart disease. It is the leading cause of death ... happens when the arteries that supply blood to heart muscle become hardened and narrowed. This is due ...

  16. Inflammation in coronary artery diseases

    Institute of Scientific and Technical Information of China (English)

    LI Jian-jun

    2011-01-01

    The concept that atherosclerosis is an inflammation has been increasingly recognized,and subsequently resulted in great interest in revealing the inflammatory nature of the atherosclerotic process.More recently,a large body of evidence has supported the idea that inflammatory mechanisms play a pivotal role throughout all phases of atherogenesis,from endothelial dysfunction and the formation of fatty streaks to plaque destabilization and the acute coronary events due to vulnerable plaque rupture.Indeed,although triggers and pathways of inflammation are probably multiple and vary in different clinical entities of atherosclerotic disorders,an imbalance between anti-inflammatory mechanisms and pro-inflammatory factors will result in an atherosclerotic progression.Vascular endothelial dysfunction and lipoprotein retention into the arterial intima have been reported as the earliest events in atherogenesis with which inflammation is linked.Inflammatory has also been extended to the disorders of coronary microvasculature,and associated with special subsets of coronary artery disease such as silent myocardial ischemia,myocardial ischemia-reperfusion,cardiac syndrome X,variant angina,coronary artery ectasia,coronary calcification and in-stent restenosis.Inflammatory biomarkers,originally studied to better understand the pathophysiology of atherosclerosis,have generated increasing interest among researches and clinicians.The identification of inflammatory biomarkers and cellular/molecular pathways in atherosclerotic disease represent important goals in cardiovascular disease research,in particular with respect of the development of therapeutic strategies to prevent or reverse atherosclerotic diseases.

  17. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  18. Cardiac CT: coronary arteries and beyond

    Energy Technology Data Exchange (ETDEWEB)

    Mahnken, Andreas H. [RWTH Aachen University, Department of Diagnostic Radiology, University Hospital, Aachen (Germany); RWTH Aachen University, Applied Medical Engineering, Aachen (Germany); Muehlenbruch, Georg; Guenther, Rolf W.; Wildberger, Joachim E. [RWTH Aachen University, Department of Diagnostic Radiology, University Hospital, Aachen (Germany)

    2007-04-15

    Multi-detector-row computed tomography (MDCT) has emerged as a rapidly developing method for non-invasive imaging of the heart. An understanding of ECG synchronization, contrast material administration, patient preparation and image post-processing is needed to optimize image quality. The basic technical principles and essentials of these technical basics are described here. Correctly applied cardiac MDCT allows imaging of the coronary arteries including coronary anatomy and stenosis detection. The same is true for evaluation of coronary artery bypass grafts and, to some extent, coronary artery stents. While quantification of total calcified plaque burden has been long established, coronary MDCT allows assessing plaque morphology and constitution. Recent approaches go beyond the coronaries and include evaluation of left ventricular function at rest and myocardial viability. In combination with experimental approaches for assessing aortic valve function and myocardial perfusion imaging, cardiac MDCT offers the potential for a comprehensive examination of the heart using a single breath-hold examination. (orig.)

  19. Multiple coronary micro-aneurysm formation after drug-eluting stent implantation

    Directory of Open Access Journals (Sweden)

    Apostolos H. Christou

    2016-05-01

    Full Text Available Although there are limited data regarding the formation of coronary artery aneurysms (CAAs after drug-eluting stent (DES implantation, CAAs appear to be a rare complication of coronary stenting. The exact mechanism of CAA formation is unknown, but several hypotheses have been proposed. As the use of DES increases, the clinical significance of these findings will become clearer. We report on a patient who developed multiple CAAs in 2 different locations after sirolimus-eluting stent implantation.

  20. Evaluation of neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography

    Institute of Scientific and Technical Information of China (English)

    TIAN Feng; CHEN Yun-dai; CHEN Lian; SUN Zhi-jun; GUO Jun; JIN Qin-hua; LIU Chang-fu

    2013-01-01

    Background The vessel healing in patients with coronary artery aneurysms (CAA) that form after drug-eluting stent (DES) implantation is not clear.This study aims to assess the vessel healing in patients with CAA formation after DES implanation.Methods From June 2008 to August 2011,follow-up coronary angiography was conducted on 1160 patients who underwent percutaneous coronary intervention (PCI).The average period of follow-up was about (18.95+13.05) months.A total of 175 patients who underwent DES implantation into de novo lesions and who underwent coronary angiography and optical coherence tomography (OCT) examination during follow-up were identified.Patients were divided into the CAA group (n=31) and non-CAA group (n=144) based on the results of the coronary angiography.The cardiac events including angina and acute myocardial infarction were noted; in addition,the neointimal thickness and the frequency of strut malapposition and strut uncoverage were also noted.Results A greater proportion of incomplete neointimal coverage (17.17% vs.1.90%,P <0.001) and strut malapposition (18.20% vs.1.38%,P <0.001) were observed in the CAA group.The neointimal thickness in the CAA group was significantly thinner than that in the non-CAA group ((146.6+94.8) μm vs.(192.5+97.1) μm,P <0.001),as detected via OCT.Patients with CAA formation had a higher frequency of cardiac events including angina pectoris (25.81% vs.6.25%,P=0.001) and acute myocardial infarction (9.68% vs.0.13%,P=0.002) and thrombosis (16.13% vs.0.69%,P <0.001).The longitudinal length of the CAA in the cardiac event group was significantly longer than in the no cardiac event group ((20.0+9.07) mm vs.(12.05+5.38) mm,P=-0.005).Conclusion CAA formation after DES implantation is frequently associated with cardiac events as a result of stent malapposition and incomplete neointimal coverage.

  1. Computer Simulation of the Mechanical Behaviour of Implanted Biodegradable Stents in a Remodelling Artery

    Science.gov (United States)

    Boland, Enda L.; Grogan, James A.; Conway, Claire; McHugh, Peter E.

    2016-04-01

    Coronary stents have revolutionised the treatment of coronary artery disease. While coronary artery stenting is now relatively mature, significant scientific and technological challenges still remain. One of the most fertile technological growth areas is biodegradable stents; here, there is the possibility to generate stents that will break down in the body once the initial necessary scaffolding period is past (6-12 months) (Grogan et al. in Acta Biomater 7:3523, 2011) and when the artery has remodelled (including the formation of neo-intima). A stent angioplasty computational test-bed has been developed by the authors, based on the Abaqus software (DS-SIMULIA, USA), capable of simulating stent tracking, balloon expansion, recoil and in vivo loading in a atherosclerotic artery model. Additionally, a surface corrosion model to simulate uniform and pitting corrosion of biodegradable stents and a representation of the active response of the arterial tissue following stent implantation, i.e. neointimal remodelling, has been developed. The arterial neointimal remodelling simulations with biodegradable stent corrosion demonstrate that the development of new arterial tissue around the stent struts has a substantial effect on the mechanical behaviour of degrading stents.

  2. Percutaneous radial intervention for complex bilateral renal artery stenosis using paclitaxel eluting stents.

    Science.gov (United States)

    Granillo, Gastón A Rodriguez; van Dijk, Lukas C; McFadden, Eugène P; Serruys, Patrick W

    2005-01-01

    Techniques used in the coronary circulation may be useful in peripheral intervention. We report a case of bilateral renal artery stenosis treated via a radial approach by direct stenting with distal protection at a right ostial lesion and modified crush stenting at a left renal bifurcation lesion using paclitaxel-eluting stents.

  3. A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymer-based sirolimus-eluting stent compared to ENDEAVOR zotarolimus-eluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up results

    Institute of Scientific and Technical Information of China (English)

    XU Bo; LI Wei-min; CHEN Ji-yan; WANG Lei; WANG Yong; GE Jun-bo; LI Wei; GAO Run-lin; DOU Ke-fei; HAN Ya-ling; L(U) Shu-zheng; YANG Yue-jin; HUO Yong; WANG Le-feng; CHEN Yun-dai; WANG Hai-chang

    2011-01-01

    Background Available drug-eluting stents (DES) have achieved great success in reducing restenosis rates. Recently,investigators have demonstrated that the durable polymer carrier plays a significant role in DES-related hypersensitive reaction and delays vessel healing. TIVOLI stent is a novel sirolimus-eluting coronary stent with biodegradable coating containing sirolimus and polylactic-co-glycolic acid (PLGA) polymer. The present study sought to evaluate the effectiveness and safety of the TIVOLI biodegradable-polymer-based sirolimus-eluting stent in treating patients with coronary artery disease.Methods A prospective, multicenter clinical trial comparing TIVOLI biodegradable coated sirolimus-eluting stent with ENDEAVOR zotarolimus-eluting stent was conducted in 324 patients (TIVOLI group: 168 patients; ENDEAVOR group:156 patients) at 12 centers in China to demonstrate the non-inferiority of in-stent late loss with TIVOLI stent compared to ENDEAVOR stent in subjects with a maximum of two de novo native coronary artery lesions (lesion length ≤40 mm,reference vessel diameter 2.25-4.00 mm). The primary end point was angiographic in-stent late loss at 8-month. The secondary end points were clinical outcomes at 2 years,including major adverse cardiac events (cardiac death,myocardial infarction, or target-lesion revascularization) and stent thrombosis.Results Angiographic late lumen loss at 8 months in the TIVOLI group was superior to the ENDEAVOR group (in-stent (0.25±0.33) mm vs. (0.57±0.55) mm, diff (95% CI)-0.23 (-0.32, -0.14), P <0.0001; in-segment (0.25±-0.33) mm vs. (0.42±-0.55) mm, diff (95% CI) -0.13 (-0.23, -0.02),P=0.0083). The rate of in-stent binary restenosis at 8 months was reduced from 8.6% in the ENDEAVOR group to 2.9% in the TIVOLI group (P=0.0229). Compared to ENDEAVOR stent, TIVOLI stent resulted in a significant reduction in target-lesion revascularization (4.2% vs. 9.6%, P=0.0495) at 2 years. The two-year major adverse cardiac events (MACE

  4. Bare-metal stenting of large coronary arteries in ST-elevation myocardial infarction is associated with low rates of target vessel revascularization.

    Science.gov (United States)

    Shugman, Ibrahim M; Hee, Leia; Mussap, Christian J; Diu, Patrick; Lo, Sidney; Hopkins, Andrew P; Nguyen, Phong; Taylor, David; Rajaratnam, Rohan; Leung, Dominic; Thomas, Liza; Juergens, Craig P; French, John K

    2013-04-01

    During percutaneous coronary intervention (PCI) performed in the emergent setting of ST-segment elevation myocardial infarction (STEMI), uncertainty about patients' ability to comply with 12 months dual antiplatelet therapy after drug-eluting stenting is common, and thus, selective bare-metal stent (BMS) deployment could be an attractive strategy if this achieved low target vessel revascularization (TVR) rates in large infarct-related arteries (IRAs) (≥3.5 mm). To evaluate this hypothesis, among 1,282 patients with STEMI who underwent PCI during their initial hospitalization, we studied 1,059 patients (83%) who received BMS, of whom 512 (48%) had large IRAs ≥3.5 mm in diameter, 333 (31%) had IRAs 3 to 3.49 mm, and 214 (20%) had IRAs <3 mm. At 1 year, TVR rate in patients with BMS was 5.8% (2.2% with large BMS [≥3.5 mm], 9.2% with BMS 3-3.49 mm [intermediate], and 9.0% with BMS <3.0 mm [small], P < .001). The rates of death/reinfarction among patients with large BMS compared with intermediate BMS or small BMS were lower (6.6% vs 11.7% vs 9.0%, P = .042). Among patients who received BMS, the independent predictors of TVR at 1 year were the following: vessel diameter <3.5 mm (odds ratio [OR] 4.39 [95% CI 2.24-8.60], P < .001), proximal left anterior descending coronary artery lesions (OR 1.89 [95% CI 1.08-3.31], P = .027), hypertension (OR 2.01 [95% CI 1.17-3.438], P = .011), and prior PCI (OR 3.46 [95% CI 1.21-9.85], P = .02). The predictors of death/myocardial infarction at 1 year were pre-PCI cardiogenic shock (OR 8.16 [95% CI 4.16-16.01], P < .001), age ≥65 years (OR 2.63 [95% CI 1.58-4.39], P < .001), left anterior descending coronary artery culprit lesions (OR 1.95 [95% CI 1.19-3.21], P = .008), female gender (OR 1.93 [95% CI 1.12-3.32], P = .019), and American College of Cardiology/American Heart Association lesion classes B2 and C (OR 2.17 [95% CI 1.10-4.27], P = .026). Bare-metal stent deployment in STEMI patients with IRAs ≥3.5 mm was associated

  5. The use of alkanethiol self-assembled monolayers on 316L stainless steel for coronary artery stent nanomedicine applications: an oxidative and in vitro stability study.

    Science.gov (United States)

    Mahapatro, Anil; Johnson, Dave M; Patel, Devang N; Feldman, Marc D; Ayon, Arturo A; Agrawal, C Mauli

    2006-09-01

    The use of self-assembled monolayers (SAMs) on medical devices offers a methodology for the incorporation of nanotechnology into medicine. SAMs are highly ordered nanosized molecular coatings, adding 1 to 10 nm thickness to a surface. This work is part of an overall goal to deliver therapeutic drugs from the surface of metal coronary stents using SAMs. In this study the oxidative and in vitro stability of functional alkylthiol SAMs on 316L stainless steel (SS) has been demonstrated. SAMs of 11-mercaptoundecanoic acid (-COOH SAM) and 11-mercapto-1-undecanol (-OH SAM) were formed on 316L SS. X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), and contact angle (CA) measurements collectively confirmed the formation of functional alkylthiol SAMs on 316L SS. Well-formed SAMs (CA: 82 deg +/- 9 deg) were achieved within 48 hours of immersion in ethanolic solutions, after which no significant improvement in CA was observed. The ratio of the thiolate peak (163.5 eV) to the oxidized sulfur (sulfonates) peak (166.5 eV) gives us an indication of the percentage SAMs that would bind to the metal and serve as a drug reservoir in vivo; which in turn represents the stability and viability of these SAMs, keeping in mind the cardiovascular application under consideration. Oxidative and in vitro stability studies showed that alkanethiol SAMs oxidized completely within 14 days. The SAMs tend to desorb and leave the metal surface after longer time periods (21 days) in phosphate-buffered saline (PBS) immersion, whereas for oxidative exposure the SAMs continue to remain on the metal surface in the form of sulfonates. Although the chemistry of bonding of alkylthiol with the 316L SS is not well understood, the nanosized alkylthiol SAMs demonstrate sufficient stability to justify further study on these systems for potential in vivo drug delivery in the chosen coronary artery stent applications.

  6. [Approaches potentiating cardioprotective effect of ambulatory physical training in patients with ischemic heart disease and multivessel coronary artery involvement after coronary stenting].

    Science.gov (United States)

    Liamina, N P; Kotel'nikova, E V; Biziaeva, E A; Karpova, É S

    2014-01-01

    Cardiorehabilitation of patients with multivessel coronary lesions is an obligatory component of ambulatory stage of care. With the aim of potentiating cardioprotective and antiischemic impact of rehabilitative preventive measures in 36 patients with ischemic heart disease (IHD) and multivessel coronary artery involvement who had undergone percutaneous coronary intervention we studied cardioprotective and antiischemic effect of long-term (24 weeks) administration of 70 mg/day trimetazidine in combination with moderate intensity physical training with the use of distance surveillance by a physician. The chosen therapeutic approach in patients with residual ischemia after incomplete anatomical revascularization provided early persistent formation of cardioprotective and antiischemic effect proven by increase of tolerance to physical exercise, improvement of diastolic function, and positive dynamics of both ECG parameters and biochemical markers of myocardial ischemia.

  7. Transient coronary aneurysm formation after Nevo™ stent implantation versus persistent coronary aneurysm after Cypher Select™ stent implantation

    DEFF Research Database (Denmark)

    Christiansen, Evald Høj; Lassen, Jens Flensted; Jensen, Lisette Okkels

    2011-01-01

    We implanted a Cypher Select™ coronary stent and two months later a Nevo™ sirolimus-eluting coronary stent in another vessel. At a prescheduled angiographic follow-up, coronary aneurysms were seen in the two stented segments, 6 and 8 months after stent implantation, respectively. Six months later...

  8. Carotid Artery Stenting 2013: Thumbs up

    Science.gov (United States)

    Wagdi, Philipp

    2013-01-01

    It has been customary for interventional cardiologists involved in carotid artery stenting, to underline non-inferiority of the percutaneous technique versus surgical carotid endarterectomy. To that end, all cause morbidity and mortality figures of both methods are compared. Surgery has, in most large randomized studies, had an edge over stenting in terms of cerebrovascular adverse events. This may have partly been due to occasional indiscriminate indication for stenting in lesions and/or vessels with unfavourable characteristics (severe target vessel tortuosity and calcification, Type III aortic arch, and so on). On one hand, the author pleads for improvement of the excellent results of endarterectomy, by subjecting all patients planned for surgery to a thorough preoperative cardiological work up, including generous invasive investigation, thus reducing the incidence of perioperative myocardial infarction, heart failure and cardiac death. On the other hand, we are convinced that the results of carotid stenting should then be compared to best practice surgery. The rate of neurological adverse event rate after carotid endarterectomy at our institution lies under 0.7% at 30 days postoperatively. Specifically, the goal should be that carotid stenting underbids surgical endarterectomy, also and mainly, in terms of cerebral and cerebrovascular adverse events. Cardiac morbidity and mortality as well as laryngeal nerve palsy should no more be the main arguments for the percutaneous approach. This should easily be possible if patient selection for carotid revascularisation would be approached according to morphological criteria, in analogy with the “Syntax”-score used to optimise revascularisation strategies in coronary artery disease.

  9. Alterations in echocardiographic left ventricular function after percutaneous coronary stenting in diabetic patients with isolated severe proximal left anterior descending artery stenosis.

    Science.gov (United States)

    Nabati, Maryam; Taghavi, Morteza; Saffar, Naser; Yazdani, Jamshid; Bagheri, Babak

    There are conflicting theories regarding the use of percutaneous coronary intervention (PCI) of isolated severe proximal left anterior descending (LAD) artery stenosis in place of left internal mammary artery grafting in diabetic patients. The aim of this study was to investigate the effect of PCI on left ventricular function and determine difference between diabetics and non-diabetics. A prospective study was conducted on 50 patients with isolated severe proximal LAD stenosis: 23 diabetic and 27 non-diabetic patients. Successful PCI with everolimus-eluting stents was performed for all of the patients. These patients underwent transthoracic echocardiography within 24h before and 1 month after PCI, and alterations in the left ventricular parameters were compared between the two groups. There was a significant 12% increment in the mitral annular peak systolic velocity (s') (p=0.02), 21% decrement in the trans mitral early filling deceleration time (DT) (p<0.001), 10% decrement in the systolic left ventricular internal dimension (LVIDs) (p=0.002), significant increment in the left ventricular ejection fraction (LVEF) (p=0.004), and significant decrement in the left atrial diameter (p=0.006) in the diabetic patients after performing PCI. Conversely, the non-diabetic patients showed a statistically significant 14% increase in the DT, 6.3% decrease in the s' velocity, 8% increase in the LVIDs, significant increment in the left atrial diameter and no change in LVEF after PCI. Our study demonstrated that everolimus-eluting stents favorably improved the markers of left ventricular systolic and diastolic function in diabetic patients with isolated severe proximal LAD stenosis compared with those of non-diabetic patients with the same condition. Copyright © 2016. Published by Elsevier B.V.

  10. The qualitative assessment of biodegradable coronary stents with the use of intravascular ultrasound, optical coherence tomography and histology

    OpenAIRE

    Burcu GÜL

    2014-01-01

    Percutaneous coronary intervention (PCI) is the most common treatment for coronary artery disease (CAD). The first form of PCI introduced was balloon angioplasty. After that, the advent of coronary stents (tubular wire mesh for intravascular mechanical support) led to a new era in interventional cardiology. Through the implantation of bare metal stents (BMS), all three limitations of balloon angioplasty – coronary artery dissection, elastic recoil and negative remodelling – are prevented. Unf...

  11. Coronary Artery Bypass

    Directory of Open Access Journals (Sweden)

    Kadri Ceberut

    2011-01-01

    Full Text Available Ancient schwannoma is a rare variant of neural tumors though rarely seen in the thorax. The combination with coronary artery diseases is also rare. Here we describe a 66 year-old male who had undergone one-stage combined surgery for thoracic ancient schwannomas removal and coronary artery disease. The masses were, respectively, 13 cm in the middle mediastinum and 5 cm in diameter originating from the intercostal nerve. The tumors were successfully removed using sternotomy, and then a coronary artery bypass grafting was performed. Here we discuss this rare tumor in relation to the relevant literature.

  12. 药物洗脱支架治疗冠状动脉疾病疗效优势的研究进展%Research Progress in the Therapeutic Advantages of Drug-eluting Stent Implantation for Coronary Artery Disease

    Institute of Scientific and Technical Information of China (English)

    郭冠兰; 黄胜堂

    2015-01-01

    药物洗脱支架(DES)取代裸金属支架(BMS)应用于临床是心脏病介入治疗领域的突破性进展. DES的介入治疗可与冠状动脉旁路移植术(CABG)媲美,后者是目前临床上治疗冠状动脉疾病的标准方法. DES可较好控制再狭窄率的效果. 此外,复杂程度较低的冠心病患者用DES进行经皮冠状动脉介入(PCI)的疗效好. 但是CABG依然是左前降支或左主干冠状动脉病以及复杂的多血管病变患者优先选择的治疗方案.%Bare-metal stents have been replaced by drug-eluting stents( DES) , which is considered as a breakthrough therapy that might compete with coronary artery bypass grafting(CABG) as the standard treat-ment for coronary artery disease.DES can control the effect of restenosis rate.In addition,less complex coro-nary heart disease patients treated by percutaneous coronary intervention with DES have better therapeutic effect.However,CABG is still the priority option for patients with left anterior descending coronary artery involvement, left main involvement, or multivessel disease.

  13. Spontaneous Coronary Artery Dissection: The Phantom Menace

    Science.gov (United States)

    Spinthakis, Nikolaos; Abdulkareem, Nada; Farag, Mohamed; Gorog, Diana A.

    2016-01-01

    We present a case of a 66-year-old lady with chest pain, without dynamic 12-lead electrocardiographic (ECG) changes and normal serial troponin. Coronary angiography revealed a linear filing defect in the first obtuse marginal branch of the circumflex artery indicating coronary artery dissection, with superadded thrombus. She was managed medically with dual antiplatelet therapy and has responded well. Spontaneous coronary artery dissection (SCAD) is a rare cause of cardiac chest pain, which can be missed without coronary angiography. Unlike most other lesions in patients with unstable symptoms, where coronary intervention with stenting is recommended, patients with SCAD generally fare better with conservative measures than with intervention, unless there is hemodynamic instability. PMID:28197295

  14. Transradial artery coronary angioplasty.

    Science.gov (United States)

    Kiemeneij, F; Laarman, G J; de Melker, E

    1995-01-01

    This study explored the feasibility and safety of percutaneous coronary balloon angioplasty (PTCA) with miniaturized PTCA equipment via the radial artery. Coronary angioplasty (PTCA) via the femoral or brachial arteries may be associated with rare vascular complications such as bleeding and damage to the artery and adjacent structures. It was postulated that PTCA via the radial artery with miniaturized angioplasty equipment is feasible and that no major puncture site-related complications occur because hemostasis is obtained easily and because no major structures are near the radial artery. With double blood supply to the hand, radial artery occlusion is well tolerated. In 100 patients with collateral blood supply to the right hand, PTCA was attempted with 6F guiding catheters and rapid-exchange balloon catheters for exertional angina (87 patients) or nonexertional angina (13 patients). Angioplasty was attempted in 122 lesions (type A n = 67 [55%], Type B n = 37 [30%], and type C n = 18 [15%]). Pre- and post-PTCA computerized quantitative coronary analysis was performed. Radial artery function and structure were assessed clinically and with Doppler and two-dimensional ultrasound on the day of discharge. Coronary catheterization via the radial artery was successful in 94 patients (94%). The 6 remaining patients had successful PTCA via the femoral artery (n = 5) or the brachial artery (n = 1). Procedural success (120 of 122 lesions) was achieved in 92 patients (98%) via the radial artery and in 98 patients of the total study population.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Hemodynamics of Stent Implantation Procedures in Coronary Bifurcations: an in vitro study

    CERN Document Server

    Brindise, Melissa C; Burzotta, Francesco; Migliavacca, Francesco; Vlachos, Pavlos P

    2016-01-01

    Stent implantation in coronary bifurcations presents unique challenges and currently there is no universally accepted stent deployment approach. Despite clinical and computational studies, to date, the effect of each stent implantation method on the coronary artery hemodynamics is not well understood. In this study the hemodynamics of stented coronary bifurcations under pulsatile flow conditions were investigated experimentally. Three implantation methods, provisional side branch (PSB), culotte (CUL), and crush (CRU), were investigated using time-resolved particle image velocimetry (PIV) to measure the velocity fields. Subsequently, hemodynamic parameters including wall shear stress (WSS), oscillatory shear index (OSI), and relative residence time (RRT) were calculated and the pressure field through the vessel was non-invasively quantified. The effects of each stented case were evaluated and compared against an un-stented case. CRU provided the lowest compliance mismatch, but demonstrated detrimental stent in...

  16. Directional atherectomy for treatment of restenosis within coronary stents: clinical, angiographic and histologic results

    NARCIS (Netherlands)

    B.H. Strauss (Bradley); V.A.W.M. Umans (Victor); R-J. van Suylen (Robert-Jan); P.J. de Feyter (Pim); J. Marco (Jean); G. Robertson; J. Renkin; G.R. Heyndrickx (Guy); V.D. Vuzevski (Vojislav); F.T.B. Bosman (Fré); P.W.J.C. Serruys (Patrick)

    1992-01-01

    textabstractAbstract OBJECTIVES: The safety and long-term results of directional coronary atherectomy in stented coronary arteries were determined. In addition, tissue studies were performed to characterize the development of restenosis. METHODS: Directional coronary atherectomy was performed in r

  17. The 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE trial: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Park Kyung

    2012-03-01

    Full Text Available Abstract Background Second-generation drug-eluting stents (DES have raised the bar of clinical performance. These stents are mostly made from cobalt chromium alloy. A newer generation DES has been developed from platinum chromium alloy, but clinical data regarding the efficacy and safety of the platinum chromium-based everolimus-eluting stent (PtCr-EES is limited, with no comparison data against the cobalt chromium-based zotarolimus-eluting stent (CoCr-ZES. In addition, an antiplatelet regimen is an integral component of medical therapy after percutaneous coronary intervention (PCI. A 1-week duration of doubling the dose of clopidogrel (double-dose antiplatelet therapy (DDAT was shown to improve outcome at 1 month compared with conventional dose in acute coronary syndrome (ACS patients undergoing PCI. However in Asia, including Korea, the addition of cilostazol (triplet antiplatelet therapy (TAT is used more commonly than doubling the dose of clopidogrel in high-risk patients. Methods In the 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE trial, approximately 3,750 patients are being prospectively and randomly assigned in a 2 × 2 factorial design according to the type of stent (PtCr-EES vs CoCr-ZES and antiplatelet regimen (TAT vs DDAT. The first primary endpoint is target lesion failure at 1 year for the stent comparison, and the second primary endpoint is net clinical outcome at 1 month for comparison of antiplatelet therapy regimen. Discussion The HOST-ASSURE trial is the largest study yet performed to directly compare the efficacy and safety of the PtCr-EES versus CoCr-ZES in an 'all-comers' population. In addition, this study will also compare the clinical outcome of TAT versus DDAT for 1-month post PCI. Trial registration ClincalTrials.gov number NCT01267734.

  18. Angioplasty and stent - heart - discharge

    Science.gov (United States)

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  19. Flow disturbances in stent-related coronary evaginations

    DEFF Research Database (Denmark)

    Radu, Maria D; Pfenniger, Aloïs; Räber, Lorenz

    2014-01-01

    Aims: Angiographic ectasias and aneurysms in stented segments have been associated with late stent thrombosis. Using optical coherence tomography (OCT), some stented segments show coronary evaginations reminiscent of ectasias. The purpose of this study was to explore, using computational fluid...

  20. Biodegradable polymer Biolimus-eluting stent (Nobori® for the treatment of coronary artery lesions: review of concept and clinical results

    Directory of Open Access Journals (Sweden)

    Schurtz G

    2014-02-01

    Full Text Available Guillaume Schurtz,1,2 Cédric Delhaye,1 Christopher Hurt,1,2 Henri Thieuleux,1,2 Gilles Lemesle1–3 1Centre Hémodynamique et Unité des Soins Intensifs de Cardiologie, Hôpital Cardiologique, Centre Hospitalier Régional et Universitaire de Lille, Lille, France; 2Faculté de Médecine de Lille, Lille, France; 3Unité INSERM UMR744, Institut Pasteur de Lille, Lille, France Abstract: First-generation drug-eluting stents have raised concerns regarding the risk of late and very late stent thrombosis compared with bare metal stents and require prolonged dual antiplatelet therapy. Despite extensive investigations, the physiopathology of these late events remains incompletely understood. Aside from patient- and lesion-related risk factors, stent polymer has been cited as one of the potential causes. In fact, the persistence of durable polymer after complete drug release has been shown to be responsible for local hypersensitivity and inflammatory reactions. Third-generation drug-eluting stents with more biocompatible or biodegradable polymers have subsequently been developed to address this problem. In this article, we evaluate and discuss the concept and clinical results (safety and efficacy of a third-generation drug-eluting stent with biodegradable polymer: the Nobori® stent. Keywords: percutaneous coronary intervention, stent thrombosis, antiplatelet therapy

  1. Woven Coronary Artery Disease Successfully Managed with Percutaneous Coronary Intervention: A New Case Report

    OpenAIRE

    Yakup Alsancak; Burak Sezenoz; Sedat Turkoglu; Adnan Abacı

    2015-01-01

    Woven coronary artery is relatively rare and can be complicated in both acute and chronic phases. A few case reports have been published until now. Herein we report a case with right woven coronary artery managed with drug-eluted stent implantation without complication.

  2. Woven Coronary Artery Disease Successfully Managed with Percutaneous Coronary Intervention: A New Case Report.

    Science.gov (United States)

    Alsancak, Yakup; Sezenoz, Burak; Turkoglu, Sedat; Abacı, Adnan

    2015-01-01

    Woven coronary artery is relatively rare and can be complicated in both acute and chronic phases. A few case reports have been published until now. Herein we report a case with right woven coronary artery managed with drug-eluted stent implantation without complication.

  3. Woven Coronary Artery Disease Successfully Managed with Percutaneous Coronary Intervention: A New Case Report

    Directory of Open Access Journals (Sweden)

    Yakup Alsancak

    2015-01-01

    Full Text Available Woven coronary artery is relatively rare and can be complicated in both acute and chronic phases. A few case reports have been published until now. Herein we report a case with right woven coronary artery managed with drug-eluted stent implantation without complication.

  4. Cost-effectiveness of paclitaxel-coated balloon angioplasty and paclitaxel-eluting stent implantation for treatment of coronary in-stent restenosis in patients with stable coronary artery disease.

    Science.gov (United States)

    Bonaventura, Klaus; Leber, Alexander W; Sohns, Christian; Roser, Mattias; Boldt, Leif-Hendrik; Kleber, Franz X; Haverkamp, Wilhelm; Dorenkamp, Marc

    2012-07-01

    Recent studies have demonstrated the safety and efficacy of drug-coated balloon (DCB) angioplasty for the treatment of coronary in-stent restenosis (ISR). The cost-effectiveness of this practice is unknown. A Markov state-transition decision analytic model accounting for varying procedural efficacy rates, complication rates, and cost estimates was developed to compare DCB angioplasty with drug-eluting stent (DES) placement in patients with bare-metal stent (BMS)-ISR. Data on procedural outcomes associated with both treatment strategies were derived from the literature, and the cost analysis was conducted from a health care payer perspective. Effectiveness was expressed as life-years gained. In the base-case analysis, initial procedure costs amounted to €3,604.14 for DCB angioplasty and to €3,309.66 for DES implantation. Over a 12-month time horizon, the DCB strategy was found to be less costly (€4,130.38 vs. €5,305.30) and slightly more effective in terms of life expectancy (0.983 vs. 0.976 years) than the DES strategy. Extensive sensitivity analyses indicated that, in comparison with DES implantation, the cost advantage of the DCB strategy was robust to clinically plausible variations in the values of key model input parameters. The variables with the greatest impact on base-case results were the duration of dual antiplatelet therapy with acetylsalicylic acid and clopidogrel after DCB angioplasty, the use of generic clopidogrel, and variations in the costs associated with the DCB device. DCB angioplasty is a cost-effective treatment option for coronary BMS-ISR. The higher initial costs of DCB are more than offset by later cost-savings, predominantly as a result of reduced medication costs.

  5. Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents: A Multivariable Statistical Analysis.

    Science.gov (United States)

    Martin, David; Boyle, Fergal

    2015-09-01

    Several clinical studies have identified a strong correlation between neointimal hyperplasia following coronary stent deployment and both stent-induced arterial injury and altered vessel hemodynamics. As such, the sequential structural and fluid dynamics analysis of balloon-expandable stent deployment should provide a comprehensive indication of stent performance. Despite this observation, very few numerical studies of balloon-expandable coronary stents have considered both the mechanical and hemodynamic impact of stent deployment. Furthermore, in the few studies that have considered both phenomena, only a small number of stents have been considered. In this study, a sequential structural and fluid dynamics analysis methodology was employed to compare both the mechanical and hemodynamic impact of six balloon-expandable coronary stents. To investigate the relationship between stent design and performance, several common stent design properties were then identified and the dependence between these properties and both the mechanical and hemodynamic variables of interest was evaluated using statistical measures of correlation. Following the completion of the numerical analyses, stent strut thickness was identified as the only common design property that demonstrated a strong dependence with either the mean equivalent stress predicted in the artery wall or the mean relative residence time predicted on the luminal surface of the artery. These results corroborate the findings of the large-scale ISAR-STEREO clinical studies and highlight the crucial role of strut thickness in coronary stent design. The sequential structural and fluid dynamics analysis methodology and the multivariable statistical treatment of the results described in this study should prove useful in the design of future balloon-expandable coronary stents.

  6. Patient-specific simulations of stenting procedures in coronary bifurcations: two clinical cases.

    Science.gov (United States)

    Morlacchi, Stefano; Colleoni, Sebastian George; Cárdenes, Rubén; Chiastra, Claudio; Diez, Jose Luis; Larrabide, Ignacio; Migliavacca, Francesco

    2013-09-01

    Computational simulations of stenting procedures in idealized geometries can only provide general guidelines and their use in the patient-specific planning of percutaneous treatments is inadequate. Conversely, image-based patient-specific tools that are able to realistically simulate different interventional options might facilitate clinical decision-making and provide useful insights on the treatment for each individual patient. The aim of this work is the implementation of a patient-specific model that uses image-based reconstructions of coronary bifurcations and is able to replicate real stenting procedures following clinical indications. Two clinical cases are investigated focusing the attention on the open problems of coronary bifurcations and their main treatment, the provisional side branch approach. Image-based reconstructions are created combining the information from conventional coronary angiography and computed tomography angiography while structural finite element models are implemented to replicate the real procedure performed in the patients. First, numerical results show the biomechanical influence of stents deployment in the coronary bifurcations during and after the procedures. In particular, the straightening of the arterial wall and the influence of two overlapping stents on stress fields are investigated here. Results show that a sensible decrease of the vessel tortuosity occurs after stent implantation and that overlapping devices result in an increased stress state of both the artery and the stents. Lastly, the comparison between numerical and image-based post-stenting configurations proved the reliability of such models while replicating stent deployment in coronary arteries.

  7. Headache after carotid artery stenting.

    Science.gov (United States)

    Suller Marti, A; Bellosta Diago, E; Velázquez Benito, A; Tejero Juste, C; Santos Lasaosa, S

    2017-04-18

    Headache after carotid artery stenting is a headache with onset during the procedure or in the first few hours after it, and where there is no evidence to suggest a complication of that procedure. The purpose of this study is to describe the main features of these headaches based on our clinical experience. Observational prospective study of a sample of patients undergoing carotid artery stenting at Hospital Clínico Universitario Lozano Blesa, in Zaragoza, Spain. We recorded sociodemographic characteristics, cardiovascular risk factors, carotid artery disease, and history of primary headache; data were gathered using structured interviews completed before and 24hours after the procedure. We included 56 patients (mean age 67±9.52 years); 84% were men. Twelve patients (21.4%) experienced headache, 83.3% of whom were men; mean age was 60.58±9.31 years. Headache appeared within the first 6hours in 7 patients (58.4%) and during the procedure in 4 (33.3%). Pain lasted less than 10minutes in 4 patients (33.3%) and between 10 and 120minutes in 5 (41.7%). Headache affected the frontotemporal area in 7 patients (58.3%); 7 patients (58.3%) described pain as unilateral. It was oppressive in 8 patients (66.7%) and of moderate intensity in 6 (50%). Nine patients (75%) required no analgesics. We found no statistically significant associations with any of the variables except for age (P=.007; t test). In our sample, headache after carotid artery stenting was mild to moderate in intensity, unilateral, oppressive, and short-lasting. Further studies are necessary to gain a deeper knowledge of its characteristics and associated risk factors. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Updates in management of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Dong Heon; Chae, Shung Chull [Kyungpook National University Medical School, Daegu (Korea, Republic of)

    2005-02-15

    Coronary artery disease (CAD) has been increasing during the last decade and is the one of major causes of death. The management of patients with coronary artery disease has evolved considerably. There are two main strategies in the management of CAD, complementary, not competitive, each other; the pharmacologic therapy to prevent and treat CAD and the percutaneous coronary intervention (PCI) to restore coronary flow. Antiplatelet drugs and cholesterol lowering drugs have central roles in pharmacotherapy. Drug eluting stent (DES) bring about revolutional changes in PCL in the management of patients with ST segment elevation acute myocardial infarction (AMI), there has been a debate on the better strategy for the restoration of coronary flow. Thrombolytic therapy is widely available and easy to administer, whereas primary PCI is less available and more complex, but more complete. Recently published evidences in the pharmacologic therapy including antiplatelet and statin, and PCI including DES and reperfusion therapy in patients with ST segment elevation AMI were reviewed.

  9. Coronary Artery Imaging in Children

    Science.gov (United States)

    2015-01-01

    Coronary artery problems in children usually have a significant impact on both short-term and long-term outcomes. Early and accurate diagnosis, therefore, is crucial but technically challenging due to the small size of the coronary artery, high heart rates, and limited cooperation of children. Coronary artery visibility on CT and MRI in children is considerably improved with recent technical advancements. Consequently, CT and MRI are increasingly used for evaluating various congenital and acquired coronary artery abnormalities in children, such as coronary artery anomalies, aberrant coronary artery anatomy specific to congenital heart disease, Kawasaki disease, Williams syndrome, and cardiac allograft vasculopathy. PMID:25741188

  10. Dissecting Sub-epicardial Hematoma Due to Coronary Perforation and Non-developing Stent

    Institute of Scientific and Technical Information of China (English)

    Guo Hangyuan; Xing Yangbo; Lee JongDae

    2007-01-01

    We report a 65-year-old man who presented with anastomotic perforation of the distal right coronary artery due to stent deployment, complicated by a small and stable dissecting sub-epicardial hematoma,and non-developing stent. The cause was unknown.

  11. Carotid artery stenting: which stent for which lesion?

    Science.gov (United States)

    Bosiers, Marc; Deloose, Koen; Verbist, Jürgen; Peeters, Patrick

    2005-01-01

    The different geometries and working principles of carotid stents (nitinol or cobalt chromium, open- or closed-cell configuration) provide each product with unique functional properties. The individual characteristics of each device may make it an attractive choice in one circumstance but render it less desirable in other situations. In approximately 75% of all procedures, all types of stents will achieve similar outcomes, making adequate device selection unnecessary. For the remaining quarter, careful preoperative screening is mandatory. In addition to eventual access issues, the choice of the optimal carotid stent depends mainly on arterial anatomy and lesion morphology. When treating a tortuous anatomy, stents with a flexible and comformable open-cell configuration are preferred. In arteries with a significant mismatch between common carotid artery and internal carotid artery diameter, cobalt chromium (Elgiloy) or tapered nitinol stents are selected. Lesions with suspected high emboligenicity are best covered with stents with a closed-cell configuration, whereas highly calcified lesions need treatment with nitinol stents. Thorough knowledge of the characteristics, advantages and disadvantages, and working principles of the different available stents is mandatory to optimally select the materials to be used for patients eligible for carotid revascularization.

  12. Left main coronary artery compression in pulmonary arterial hypertension

    DEFF Research Database (Denmark)

    Al-Badri, Kadhem Helo Abbas; Jensen, Jesper Møller; Christiansen, Evald H

    2015-01-01

    In patients with pulmonary arterial hypertension (PAH), chest pain is most likely due to right ventricular demand ischemia. We report a patient with idiopathic PAH who developed severe angina due to extrinsic compression of the left main coronary artery (LMCA) from a dilated pulmonary artery trunk....... The diagnosis was verified by electrocardiogram after exercise, coronary angiography including intravascular ultrasound, and cardiac multidetector computed tomography (MDCT). The origin of the LMCA was high in the left coronary sinus, facilitating extrinsic compression. The patient was successfully treated...... by percutaneous coronary intervention with stent implantation in the LMCA. Extrinsic compression of the LMCA is a severe and potentially fatal complication that should be considered in all patients with PAH and angina. MDCT is the method of choice for first-line diagnosis....

  13. Geometry parameterization and multidisciplinary constrained optimization of coronary stents.

    Science.gov (United States)

    Pant, Sanjay; Bressloff, Neil W; Limbert, Georges

    2012-01-01

    Coronary stents are tubular type scaffolds that are deployed, using an inflatable balloon on a catheter, most commonly to recover the lumen size of narrowed (diseased) arterial segments. A common differentiating factor between the numerous stents used in clinical practice today is their geometric design. An ideal stent should have high radial strength to provide good arterial support post-expansion, have high flexibility for easy manoeuvrability during deployment, cause minimal injury to the artery when being expanded and, for drug eluting stents, should provide adequate drug in the arterial tissue. Often, with any stent design, these objectives are in competition such that improvement in one objective is a result of trade-off in others. This study proposes a technique to parameterize stent geometry, by varying the shape of circumferential rings and the links, and assess performance by modelling the processes of balloon expansion and drug diffusion. Finite element analysis is used to expand each stent (through balloon inflation) into contact with a representative diseased coronary artery model, followed by a drug release simulation. Also, a separate model is constructed to measure stent flexibility. Since the computational simulation time for each design is very high (approximately 24 h), a Gaussian process modelling approach is used to analyse the design space corresponding to the proposed parameterization. Four objectives to assess recoil, stress distribution, drug distribution and flexibility are set up to perform optimization studies. In particular, single objective constrained optimization problems are set up to improve the design relative to the baseline geometry-i.e. to improve one objective without compromising the others. Improvements of 8, 6 and 15% are obtained individually for stress, drug and flexibility metrics, respectively. The relative influence of the design features on each objective is quantified in terms of main effects, thereby suggesting the

  14. Coronary Artery Disease

    DEFF Research Database (Denmark)

    Christiansen, Morten Krogh

    2017-01-01

    A family history of coronary artery disease (CAD) is an important risk factor for adverse coronary events, in particular if the disease has an early onset. The risk of CAD is influenced by genetic and environmental factors with a greater genetic contribution earlier in life. Through recent years...... Registry and risk factor control was evaluated. The study revealed that risk factors are common in early-onset CAD and that a large room for risk factor improvement remains. In study II, we used coronary computed tomography angiography to compare the coronary plaque burden and characteristics between 88...... first-degree relatives of patients with early-onset CAD and 88 controls with no familial predisposition. Relatives had a significantly increased coronary plaque burden, which displayed characteristics associated with myocardial ischemia and adverse coronary events. In study III, 134 patients with early...

  15. Impact of myocardial bridge on clinical outcome after coronary stent placement.

    Science.gov (United States)

    Tsujita, Kenichi; Maehara, Akiko; Mintz, Gary S; Doi, Hiroshi; Kubo, Takashi; Castellanos, Celia; Liu, Jian; Yang, Junqing; Oviedo, Carlos; Franklin-Bond, Theresa; Sugirtharaj, Dorcas Deborah; Dangas, George D; Lansky, Alexandra J; Stone, Gregg W; Moses, Jeffrey W; Leon, Martin B; Mehran, Roxana

    2009-05-15

    Most intravascular ultrasound (IVUS)-identifiable myocardial bridges (MBs) were not appreciated angiographically, especially when they occurred adjacent to fixed proximal obstructive disease. The impact of MB stent placement on clinical outcome was determined in 317 consecutive patients with obstructive left anterior descending coronary artery lesions undergoing coronary stent placement. In these patients, IVUS identified 70 MBs, defined as a segment of coronary artery with both systolic compression and perivascular echolucent muscle. IVUS showed that the stent extended into the MB segment beyond the obstructive lesion in 24 patients (34%; MB stent group), although significant plaque was not observed within any MB segment. In the remaining 46 patients, the left anterior descending artery stent was implanted in only the obstructive lesion, avoiding the distal MB segment (non-MB stent group). Minimum stent area was significantly smaller in the MB stent group than non-MB stent group (4.8 +/- 1.1 vs 5.8 +/- 1.8 mm(2); p = 0.02). Rates of target-lesion revascularization, target-vessel revascularization, and composite end point (death/myocardial infarction/target-lesion revascularization/target-vessel revascularization, evaluated at a mean follow-up of 358 +/- 252 days) were more common in patients with versus without MB stent placement. Specifically, target-lesion revascularization rates were 24% versus 3%, respectively (log-rank p = 0.003). In-stent restenosis occurred within the stented MB segment in 3 of 5 MB stent group patients who required target-lesion revascularization (60%). In conclusion, inadvertent MB stent placement in left anterior descending artery lesions occurred commonly and may have been associated with an increased incidence of late events.

  16. Coronary stenting with cardiogenic shock due to acute ascending aortic dissection

    Institute of Scientific and Technical Information of China (English)

    Yuichi; Hanaki; Kazuhiko; Yumoto; Seigen; I; Hajime; Aoki; Tomoyuki; Fukuzawa; Takahiro; Watanabe; Kenichi; Kato

    2015-01-01

    A 65-year-old man developed chest pain under cardiogenic shock. Coronary angiography revealed severe stenosis from the ostium of the left main coronary artery(LMCA) to the left anterior descending artery(LAD). Intravascular ultrasound(IVUS) identified a large hematoma that originated from the aorta and extended into the LAD, thereby compressing the true lumen. Type A aortic dissection(TAAD) that involved the LMCA was diagnosed by IVUS. Coronary stenting was performed via the LMCA to the proximal LAD, which resulted in coronary blood flow restoration and no further propagation of dissection. Elective surgical aortic repair was performed 2 wk after the stenting. LMCA stenting under IVUS guidance is effective for prompt diagnosis and precise stent deployment in patients with cardiogenic shock due to TAAD with LMCA dissection.

  17. Heparin-coated Palmaz-Schatz Stents in Human Coronary Arteries. . : Early Outcome of the Benestent-II Pilot Study

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); H.U. Emanuelsson (Hakan); A.C. Lunn; F. Kiemeneij (Ferdinand); C.M. Miguel (Carlos); W.R. Rutsch (Wolfgang); G.R. Heyndrickx (Guy); H. Suryapranata (Harry); V.M.G. Legrand (Victor); J-J. Goy (Jean-Jacques); P.H. Materne (Phillipe); J.J.R.M. Bonnier (Hans); M-C. Morice (Marie-Claude); J. Fajadet (Jean); J.A. Belardi (Jorge); A. Colombo (Antonio); E. Garcia (Eulogio); P.N. Ruygrok (Peter); M-A.M. Morel (Marie-Angèle); W.J. van der Giessen (Wim); P.P.T. de Jaegere (Peter)

    1996-01-01

    textabstractBackground The purpose of the Benestent-II Pilot Study was to evaluate the safety of delaying and eliminating anticoagulant therapy in patients receiving a heparin-coated stent in conjunction with antiplatelet drugs. Methods and Results The study consisted of three initial phases (I, II

  18. Neoatherosclerosis:Coronary stents seal atherosclerotic lesions but result in making a new problem of atherosclerosis

    Institute of Scientific and Technical Information of China (English)

    Hidenori; Komiyama; Masamichi; Takano; Noritake; Hata; Yoshihiko; Seino; Wataru; Shimizu; Kyoichi; Mizuno

    2015-01-01

    Chronic inflammation of the native vessel wall with infiltration of lipid-laden foamy macrophages through impaired endothelium results in atherosclerosis. Percutaneous coronary intervention, including metallic stent implantation, is now widely utilized for the treatment of atherosclerotic lesions of the coronary artery. Baremetal stents and the subsequently developed drugeluting stents seal the atherosclerosis and resolve lumen stenosis or obstruction of the epicardial coronary artery and myocardial ischemia. After stent implantation, neointima proliferates within the stented segment. Chronic inflammation caused by a foreign body reaction to the implanted stent and subsequent neovascularization, which is characterized by the continuous recruitment of macrophages into the vessel, result in the transformation of the usual neointima into an atheromatous neointima. Neointima with an atherosclerotic appearance, such as that caused by thin-cap fibroatheromas, is now recognized as neoatherosclerosis, which can sometimes cause in-stent restenosis and acute thrombotic occlusion originating from the stent segment following disruption of the atheroma. Neoatherosclerosis is emerging as a new coronary stent-associated problem that has not yet been resolved. In this review article, we will discuss possible mechanisms, clinical challenges, and the future outlook of neoatherosclerosis.

  19. Percutaneous coronary intervention versus bypass surgery for left main coronary artery disease: A meta-analysis of randomised trials

    NARCIS (Netherlands)

    G. Ferrante (Giuseppe); P. Presbitero (Patrizia); M. Valgimigli (Marco); M-C. Morice (Marie-Claude); P. Pagnotta (Paolo); G. Belli (Guido); E. Corrada (Elena); Y. Onuma (Yoshinobu); P. Barlis (Peter); D. Locca (Didier); E. Eeckhout; C. di Mario (Carlo); P.W.J.C. Serruys (Patrick)

    2011-01-01

    textabstractAims: We performed a meta-analysis of randomised trials comparing percutaneous coronary intervention (PCI) with stent implantation to coronary artery bypass grafting (CABG) for the treatment of unprotected left main coronary artery stenosis (ULMCA). Methods and results: Pubmed and other

  20. Development and characterization of a coronary polylactic acid stent prototype generated by selective laser melting.

    Science.gov (United States)

    Flege, Christian; Vogt, Felix; Höges, Simon; Jauer, Lucas; Borinski, Mauricio; Schulte, Vera A; Hoffmann, Rainer; Poprawe, Reinhart; Meiners, Wilhelm; Jobmann, Monika; Wissenbach, Konrad; Blindt, Rüdiger

    2013-01-01

    In-stent restenosis is still an important issue and stent thrombosis is an unresolved risk after coronary intervention. Biodegradable stents would provide initial scaffolding of the stenosed segment and disappear subsequently. The additive manufacturing technology Selective Laser Melting (SLM) enables rapid, parallel, and raw material saving generation of complex 3- dimensional structures with extensive geometric freedom and is currently in use in orthopedic or dental applications. Here, SLM process parameters were adapted for poly-L-lactid acid (PLLA) and PLLA-co-poly-ε-caprolactone (PCL) powders to generate degradable coronary stent prototypes. Biocompatibility of both polymers was evidenced by assessment of cell morphology and of metabolic and adhesive activity at direct and indirect contact with human coronary artery smooth muscle cells, umbilical vein endothelial cells, and endothelial progenitor cells. γ-sterilization was demonstrated to guarantee safety of SLM-processed parts. From PLLA and PCL, stent prototypes were successfully generated and post-processing by spray- and dip-coating proved to thoroughly smoothen stent surfaces. In conclusion, for the first time, biodegradable polymers and the SLM technique were combined for the manufacturing of customized biodegradable coronary artery stent prototypes. SLM is advocated for the development of biodegradable coronary PLLA and PCL stents, potentially optimized for future bifurcation applications.

  1. Coronary Artery Anomalies in Animals

    Directory of Open Access Journals (Sweden)

    Brian A. Scansen

    2017-04-01

    Full Text Available Coronary artery anomalies represent a disease spectrum from incidental to life-threatening. Anomalies of coronary artery origin and course are well-recognized in human medicine, but have received limited attention in veterinary medicine. Coronary artery anomalies are best described in the dog, hamster, and cow though reports also exist in the horse and pig. The most well-known anomaly in veterinary medicine is anomalous coronary artery origin with a prepulmonary course in dogs, which limits treatment of pulmonary valve stenosis. A categorization scheme for coronary artery anomalies in animals is suggested, dividing these anomalies into those of major or minor clinical significance. A review of coronary artery development, anatomy, and reported anomalies in domesticated species is provided and four novel canine examples of anomalous coronary artery origin are described: an English bulldog with single left coronary ostium and a retroaortic right coronary artery; an English bulldog with single right coronary ostium and transseptal left coronary artery; an English bulldog with single right coronary ostium and absent left coronary artery with a prepulmonary paraconal interventricular branch and an interarterial circumflex branch; and a mixed-breed dog with tetralogy of Fallot and anomalous origin of all coronary branches from the brachiocephalic trunk. Coronary arterial fistulae are also described including a coronary cameral fistula in a llama cria and an English bulldog with coronary artery aneurysm and anomalous shunting vessels from the right coronary artery to the pulmonary trunk. These examples are provided with the intent to raise awareness and improve understanding of such defects.

  2. Computational hemodynamics of an implanted coronary stent based on three-dimensional cine angiography reconstruction.

    Science.gov (United States)

    Chen, Mounter C Y; Lu, Po-Chien; Chen, James S Y; Hwang, Ned H C

    2005-01-01

    Coronary stents are supportive wire meshes that keep narrow coronary arteries patent, reducing the risk of restenosis. Despite the common use of coronary stents, approximately 20-35% of them fail due to restenosis. Flow phenomena adjacent to the stent may contribute to restenosis. Three-dimensional computational fluid dynamics (CFD) and reconstruction based on biplane cine angiography were used to assess coronary geometry and volumetric blood flows. A patient-specific left anterior descending (LAD) artery was reconstructed from single-plane x-ray imaging. With corresponding electrocardiographic signals, images from the same time phase were selected from the angiograms for dynamic three-dimensional reconstruction. The resultant three-dimensional LAD artery at end-diastole was adopted for detailed analysis. Both the geometries and flow fields, based on a computational model from CAE software (ANSYS and CATIA) and full three-dimensional Navier-Stroke equations in the CFD-ACE+ software, respectively, changed dramatically after stent placement. Flow fields showed a complex three-dimensional spiral motion due to arterial tortuosity. The corresponding wall shear stresses, pressure gradient, and flow field all varied significantly after stent placement. Combined angiography and CFD techniques allow more detailed investigation of flow patterns in various segments. The implanted stent(s) may be quantitatively studied from the proposed hemodynamic modeling approach.

  3. Efficacy and safety of a biodegradable polymer Cobalt-Chromium sirolimus-eluting stent (EXCEL2) in treating de novo coronary artery disease: A pooled analysis of the CREDIT II and CREDIT III trials.

    Science.gov (United States)

    Wang, Geng; Wang, Heyang; Xu, Bo; Yang, Yuejin; Yang, Zhiming; Li, Hui; Zhang, Zheng; Wang, Haichang; Yang, Lixia; Han, Yaling

    2017-03-01

    The safety and efficacy of the second-generation biodegradable polymer Cobalt-Chromium sirolimus-eluting stent (EXCEL2) in daily clinical practice remains unknown. Additionally, to meet the China Food and Drug Administration requirements, we conducted an objective performance criterion study from the CREDIT II and CREDIT III trials. CREDIT II was a randomized trial comparing the EXCEL2 versus EXCEL stent in patients with up to 2 de novo coronary lesions. CREDIT III was a prospective, single-arm study evaluating the efficacy and safety of EXCEL2 in broad types of de novo coronary artery lesions. This pooled analysis included patients in the CREDIT III and EXCEL2 arm of the CREDIT II trial. The primary outcome was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinical indicated target lesion revascularization (CI-TLR). The patient-oriented composite endpoint (PoCE) of all-cause death, all MI, or any revascularization was also analyzed. A total of 833 patients were included, consisting of 625 in the CREDIT III trial and 208 in the EXCEL2 arm of the CREDIT II trial. Twelve-month TLF occurred in 6.1% patients, cardiac death in 0.4%, TV-MI in 5%, and CI-TLR in 1.1%. Additionally, 64 (7.7%) PoCE and 3 probable late stent thromboses (0.4%) were recorded. EXCEL2 stent met the objective performance criterion on efficacy and safety with a low level of 12-month TLF as well as stent thrombosis when treating patients with de novo coronary lesions. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  4. Determinants of neointimal proliferation and stent coverage after intracoronary therapy with drug-eluting devices in stable coronary artery disease: role of endothelial progenitor cells and interleukin-1 family cytokines.

    Science.gov (United States)

    Otto, Sylvia; Nitsche, Kristina; Jung, Christian; Gassdorf, Johannes; Janiak, Florian; Goebel, Björn; Figulla, Hans R; Poerner, Tudor C

    2014-12-01

    Endothelial progenitor cells (EPCs) and cytokines seem to play a pivotal role in arterial healing after stent implantation. Using optical coherence tomography (OCT) as a high-resolution imaging technique, we aimed to assess the influence of circulating EPCs and levels of Il-1 cytokines on stent coverage and in-stent proliferation. Eighty-nine patients were randomly treated with either Xience V drug-eluting stent (DES; n = 48) or bare-metal stent (BMS) postdilated with the SeQuent Please drug-eluting balloon (DEB; n = 41). EPC populations (CD34+/CD133+ and CD34+/CD133+/KDR+ EPC) and cytokines (Il-1ra, Il-18, and Il-1α) were measured before percutaneous coronary intervention using flow cytometry or immunoassay. Vessel remodeling was analyzed using coronary angiography and OCT at 6-month follow-up. Indexed neointimal volume and maximal proliferation thickness correlated inversely with EPC levels in the entire study population (r = -0.220; P=.04 and r = -0.253; P=.02) and the BMS + DEB subgroup (r = -0.344; P=.03 and r = -0.374; P=.02). Late lumen loss (LLL) was associated with the proatherogenic Il-18 concentration in the main population (r = 0.342; P=.01) and the BMS + DEB group (r = 0.471; P=.01). In the DES subgroup, associations with proliferation and LLL were lacking. Associations for stent strut coverage were not observed. A high EPC count seems to be a favorable individual patient factor, since it was associated with less instent proliferation. Contrarily, high Il-18 levels lead to more LLL, which emphasizes its proatherogenic properties.

  5. 5A/6A Polymorphism of the Stromelysin-1 Gene and Angiographic Restenosis After Coronary Artery Stenting

    Directory of Open Access Journals (Sweden)

    Kuan-Rau Chiou

    2005-11-01

    Conclusion: There is a low frequency of the stromelysin-1 promoter 5A allele in the Chinese population in Taiwan. How stromelysin-1 5A/6A polymorphism affects ISR appears to be linked to angina status. These results merit further study to identify patients carrying genotypes which put them at increased risk of ISR, and which matrix metalloproteinase inhibitors or drug-eluting stents are more effective for those at risk.

  6. Heparin-coated Palmaz-Schatz Stents in Human Coronary Arteries. .: Early Outcome of the Benestent-II Pilot Study

    OpenAIRE

    Serruys, Patrick; Emanuelsson, Hakan; Lunn, A.C.; Kiemeneij, Ferdinand; Miguel, Carlos; Rutsch, Wolfgang; Heyndrickx, Guy; Suryapranata, Harry; Legrand, Victor; Goy, Jean-Jacques; Materne, Phillipe; Bonnier, Hans; Morice, Marie-Claude; Fajadet, Jean; Belardi, Jorge

    1996-01-01

    textabstractBackground The purpose of the Benestent-II Pilot Study was to evaluate the safety of delaying and eliminating anticoagulant therapy in patients receiving a heparin-coated stent in conjunction with antiplatelet drugs. Methods and Results The study consisted of three initial phases (I, II, III) during which resumption of heparin therapy after sheath removal was progressively deferred by 6, 12, and 36 hours. In phase IV, coumadin and heparin were replaced by 250 mg ticlopidine and 10...

  7. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery disease who we...

  8. Behaviour of implantable coronary stents during magnetic resonance imaging.

    Science.gov (United States)

    Friedrich, Matthias G; Strohm, Oliver; Kivelitz, Dietmar; Gross, Werner; Wagner, Anja; Schulz-Menger, Jeanette; Liu, Xiaomeng; Hamm, Bernd

    1999-01-01

    BACKGROUND: Magnetic resonance imaging (MRI) becomes more and more a routine diagnostic tool in clinical cardiology. In patients undergoing MRI, metallic implants may be harmful by motion or heating under certain circumstances. Many cardiac patients have implanted intracoronary stents. However, the safety of these metallic implants and especially their temperature behaviour during MRI has not been sufficiently tested. METHODS: This study investigated motion and temperature changes of 14 different stents for intracoronary application in two clinical scanners at field strengths of 1.0 and 1.5 T. At 1.5 T these studies were repeated after implantation of the stents into the coronary arteries of excised porcine hearts. Furthermore, the clinical status of 33 patients was assessed after a cardiac MR study and compared with a group of 33 patients matched for age, sex and risk factors for restenosis. RESULTS: No visible motion of the stents was observed. Furthermore, using a highly sensitive infrared camera any significant heating of the stents during MRI could be excluded. The rate of clinical events was not different in patients after MRI as compared with the control group. CONCLUSION: It is concluded that MRI is safe in patients with the currently available intracoronary stents.

  9. A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program

    Directory of Open Access Journals (Sweden)

    Wehrenberg Scott

    2010-01-01

    Full Text Available Abstract Background Paclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation paclitaxel-eluting stent which incorporates a novel, thinner-strut, platinum-enriched metal alloy platform. The stent is intended to have enhanced radiopacity and improved deliverability compared to other paclitaxel-eluting stents. The safety and efficacy of the TAXUS Element stent are being evaluated in the pivotal PERSEUS clinical trials. Methods/Design The PERSEUS trials include two parallel studies of the TAXUS Element stent in single, de novo coronary atherosclerotic lesions. The PERSEUS Workhorse study is a prospective, randomized (3:1, single-blind, non-inferiority trial in subjects with lesion length ≤28 mm and vessel diameter ≥2.75 mm to ≤4.0 mm which compares TAXUS Element to the TAXUS Express2 paclitaxel-eluting stent system. The Workhorse study employs a novel Bayesian statistical approach that uses prior information to limit the number of study subjects exposed to the investigational device and thus provide a safer and more efficient analysis of the TAXUS Element stent. PERSEUS Small Vessel is a prospective, single-arm, superiority trial in subjects with lesion length ≤20 mm and vessel diameter ≥2.25 mm to Discussion The TAXUS PERSEUS clinical trial program uses a novel statistical approach to evaluate whether design and metal alloy iterations in the TAXUS Element stent platform provide comparable safety and improved procedural performance compared to the previous generation Express stent. PERSEUS trial enrollment is complete and primary endpoint data are expected in 2010. PERSEUS Workhorse and Small Vessel are registered at http://www.clinicaltrials.gov, identification numbers NCT00484315 and NCT00489541.

  10. Biomimicry, vascular restenosis and coronary stents.

    Science.gov (United States)

    Schwartz, R S; van der Giessen, W J; Holmes, D R

    1998-01-01

    Biomimicry is in its earliest stages and is being considered in the realm of tissue engineering. If arterial implants are to limit neointimal thickening, purely passive structures cannot succeed. Bioactivity must be present, either by pharmacologic intervention or by fabricating a 'living stent' that contains active cellular material. As tissue engineering evolves, useful solutions will emerge from applying this knowledge directly to vascular biologic problems resulting from angioplasty, stenting, and vascular prosthesis research.

  11. Circadian Variation in Coronary Stent Thrombosis

    NARCIS (Netherlands)

    Mahmoud, Karim D.; Lennon, Ryan J.; Ting, Henry H.; Rihal, Charanjit S.; Holmes, David R.

    2011-01-01

    Objectives We sought to determine the circadian, weekly, and seasonal variation of coronary stent thrombosis. Background Other adverse cardiovascular events such as acute myocardial infarction are known to have higher incidences during the early morning hours, Mondays, and winter months. Methods The

  12. Impact of biodegradable versus durable polymer drug-eluting stents on clinical outcomes in patients with coronary artery disease: a meta-analysis of 15 randomized trials

    Institute of Scientific and Technical Information of China (English)

    Zhang Yaojun; Tian Nailiang; Dong Shengjie; Ye Fei; Li Minghui; Christos V.Bourantas; Javaid Iqbal

    2014-01-01

    Background Drug eluting stents (DESs) made with biodegradable polymer have been developed in an attempt to improve clinical outcomes.However,the impact of biodegradable polymers on clinical events and stent thrombosis (ST) remains controversial.Methods We searched Medline,the Cochrane Library and other internet sources,without language or date restrictions for articles comparing clinical outcomes between biodegradable polymer DES and durable polymer DES.Safety endpoints were ST (definite,definite/probable),mortality,and myocardial infarction (MI).Efficacy endpoints were major adverse cardiac event (MACE) and target lesion revascularization (TLR).Results We identified 15 randomized controlled trials (n=17 068) with a weighted mean follow-up of 20.6 months.There was no statistical difference in the incidence of definite/probable ST between durable polymer-and biodegradable polymerDES; relative risk (RR) 0.83; 95% confidence interval (CI) 0.62-1.11; P=0.22.Biodegradable polymer DES had similar rates of definite ST (RR 0.94,95% CI 0.66-1.33,P=0.72),mortality (RR 0.94,95% C/0.82-1.09,P=0.43),MI (RR 1.08,95% CI 0.92-1.26.P=0.35),MACE (RR 0.99,95% CI 0.91-1.09,P=0.85),and TLR (RR,0.94,95% CI 0.83-1.06,P=0.30) compared with durable polymer DES.Based on the stratified analysis of the included trials,the treatment effect on definite ST was different at different follow-up times:≤1 year favoring durable polymer DES and >1 year favoring biodegradable polymer DES.Conclusions Biodegradable polymer DES has similar safety and efficacy for treating patients with coronary artery disease compared with durable polymer DES.Further data with longer term follow-up are warranted to confirm the potential benefits of biodegradable polymer DES.

  13. The Relationships between Polymorphisms in Genes Encoding the Growth Factors TGF-β1, PDGFB, EGF, bFGF and VEGF-A and the Restenosis Process in Patients with Stable Coronary Artery Disease Treated with Bare Metal Stent.

    Directory of Open Access Journals (Sweden)

    Tadeusz Osadnik

    Full Text Available Neointima forming after stent implantation consists of vascular smooth muscle cells (VSMCs in 90%. Growth factors TGF-β1, PDGFB, EGF, bFGF and VEGF-A play an important role in VSMC proliferation and migration to the tunica intima after arterial wall injury. The aim of this paper was an analysis of functional polymorphisms in genes encoding TGF-β1, PDGFB, EGF, bFGF and VEGF-A in relation to in-stent restenosis (ISR.265 patients with a stable coronary artery disease (SCAD hospitalized in our center in the years 2007-2011 were included in the study. All patients underwent stent implantation at admission to the hospital and had another coronary angiography performed due to recurrence of the ailments or a positive result of the test assessing the coronary flow reserve. Angiographically significant ISR was defined as stenosis >50% in the stented coronary artery segment. The patients were divided into two groups-with angiographically significant ISR (n = 53 and without significant ISR (n = 212. Additionally, the assessment of late lumen loss (LLL in vessel was performed. EGF rs4444903 polymorphism was genotyped using the PCR-RFLP method whilst rs1800470 (TGFB1, rs2285094 (PDGFB rs308395 (bFGF and rs699947 (VEGF-A were determined using the TaqMan method.Angiographically significant ISR was significantly less frequently observed in the group of patients with the A/A genotype of rs1800470 polymorphism (TGFB1 versus patients with A/G and G/G genotypes. In the multivariable analysis, LLL was significantly lower in patients with the A/A genotype of rs1800470 (TGFB1 versus those with the A/G and G/G genotypes and higher in patients with the A/A genotype of the VEGF-A polymorphism versus the A/C and C/C genotypes. The C/C genotype of rs2285094 (PDGFB was associated with greater LLL compared to C/T heterozygotes and T/T homozygotes.The polymorphisms rs1800470, rs2285094 and rs6999447 of the TGFB1, PDGFB and VEGF-A genes, respectively, are associated with LLL

  14. A randomized optical coherence tomography study of coronary stent strut coverage and luminal protrusion with rapamycin-eluting stents.

    Science.gov (United States)

    Moore, Philip; Barlis, Peter; Spiro, Jonathan; Ghimire, Gopal; Roughton, Michael; Di Mario, Carlo; Wallis, William; Ilsley, Charles; Mitchell, Andrew; Mason, Mark; Kharbanda, Rajesh; Vincent, Peter; Sherwin, Spencer; Dalby, Miles

    2009-05-01

    We used optical coherence tomography, which has a resolution of Translumina, Hechingen, Germany) to examine neointimal thickness, stent strut coverage, and protrusion at 90 days. Twenty-four patients (n = 12 for each group) underwent stent deployment and invasive follow-up at 90 days with optical coherence tomography. The primary end point was binary stent strut coverage. Coprimary end points were neointimal thickness and stent strut luminal protrusion. No patient had angiographic restenosis. For polymer-coated and nonpolymer rapamycin-eluting stents, respectively, mean (SD), neointimal thickness was 77.2 (25.6) microm versus 191.2 (86.7) mum (p 10% of struts being uncovered. High-resolution imaging allowed development of the concept of the protrusion index, and >25% of struts protruded into the vessel lumen with the polymer-coated rapamycin-eluting stent compared with <5% with the nonpolymer rapamycin-eluting stent. These findings may have important implications for the risk of stent thrombosis and, therefore, future stent design. (An optical coherence tomography study to determine stent coverage in polymer coated versus bare metal rapamycin eluting stents. ORCA 1, from the Optimal Revascularization of the Coronary Arteries group; ISRCTN42475919).

  15. Cox regression analysis of related risk factors for in-stent restenosis after coronary artery stent implanting%冠状动脉支架植入术后支架内再狭窄相关危险因素Cox回归分析

    Institute of Scientific and Technical Information of China (English)

    张园; 陆欣

    2016-01-01

    目的:回顾性分析冠状动脉支架植入术后冠心病患者的临床资料,探讨支架内再狭窄(in-stent restenosis,ISR)的危险因素。方法选择2012年8月至2014年7月于本院行冠状动脉支架植入术后的120例冠心病患者为研究对象,根据冠状动脉造影结果将其分为ISR组(38例)和非ISR组(82例)。回顾性分析两组患者的临床资料,采用Cox回归分析冠状动脉支架植入术后患者发生ISR的相关危险因素。结果 ISR组与非ISR组吸烟、糖尿病、术后不规范抗凝患者所占比例及使用非药物涂层支架数量、支架直径、支架长度比较差异均具有显著性(P<0.05)。ISR组患者脂蛋白a、纤维蛋白原、总胆红素、低密度脂蛋白水平均显著高于非ISR组(P<0.05)。Cox回归分析表明:吸烟、使用非药物支架、支架长度>20 mm、支架直径<3 mm是冠心病患者支架植入术后发生ISR的独立危险因素(P<0.05)。结论冠状动脉支架植入术后发生ISR的危险因素为吸烟、使用非药物涂层支架、支架长度>20 mm与支架直径<3 mm,需加强对危险人群的监测,以降低ISR的发生风险。%Objective To investigate the related risk factors for in-stent restenosis (ISR) after coronary artery stent implanting by retrospective analysis clinical data of patients with coronary heart disease. Method A total of 120 patients with coronary heart disease who underwent coronary artery stent implanting for treatment from August 2012 to July 2014 in our hospital were selected as objects of study. According to the results of coronary angiography, they were divided into ISR group (38 cases) and non-ISR group (82 cases). The clinical data of patients between the two groups were retrospectively analyzed. Related risk factors of ISR after coronary artery seutimplanting were analyzed by Cox regression analysis. Result The rate of smoking, diabetes, unstandardized

  16. Case Report: Coronary arterial spasm in single right coronary artery

    Institute of Scientific and Technical Information of China (English)

    En-zhi JIA; Qi-jun SHAN; Zhi-jian YANG; Tie-bing ZHU; Lian-sheng WANG; Ke-jiang CAO; Wen-zhu MA

    2009-01-01

    We presented a case of anomalous single-coronary artery detected incidentally during routine coronary angiography. A 32-year-old male Chinese patient presented with recurrent pre-syncope and six episodes of syncope. Coronary angiography and coronary-computed tomography (CT)-angiography performed by a dual-source computed tomography (DSCT) revealed that the patient had a single large right coronary artery. A moderately large branch originated from the proximal part of the single right coronary artery and extended to the left, passing the anterior to the pulmonary artery, and divided into the anterior descending artery branch and circumflex branch at the base of the left auricular appendage. The episodes of the syncope were suspected to be caused by coronary arterial spasm, so this patient was on a regimen of 30 mg of diltiazem every 6 h and had no recurrence of syncope during follow-up.

  17. [Emergency coronary artery bypass grafting for acute coronary syndrome].

    Science.gov (United States)

    Yamaguchi, Atsushi; Murayama, Takanori

    2012-09-01

    Since the drug eluting stents appeared in Japan, the indication for percutaneous coronary intervention has become wide-spread for the treatment of coronary artery disease. In the past decade, 216 patients underwent emergency/urgent coronary artery bypass grafting (CABG) in our institution, while the annual numbers of both emergency and elective CABG cases have declined. On the contrary to the decreasing number, emergency CABG patients were significantly getting older with multiple co-morbidities. Thus, off-pump CABG is likely to be beneficial for preventing postoperative complications, leading to the decreased postoperative mortality. When emergency CABG patients developed refractory myocardial ischemia and unstable hemodynamics, a percutaneous cardiopulmonary support system was quickly applicable and useful for on-pump beating CABG achieving complete surgical revascularization. For keeping satisfactory hemodynamics during CABG, communication between cardiovascular surgeons, anesthesiologists, and perfusionists is most important.

  18. First report of a novel abluminal groove filled biodegradable polymer rapamycin-eluting stent in de novo coronary artery disease: results of the first in man FIREHAWK trial

    Institute of Scientific and Technical Information of China (English)

    QIAN Jie; Gary S.Mintz; Martin B.Leon; GAO Run-lin; XU Bo; Alexandra J.Lansky; YANG Yue-jin; QIAO Shu-bin; WU Yong-jian; CHEN Jue; HU Feng-huan; YANG Wei-xian

    2012-01-01

    Background Durable polymers used for first-generation drug-eluting stents (DES) potentially contribute to persistent inflammation and late DES thrombosis.We report the first in human experience with the rapamycin-eluting biodegradable polymer coated cobalt-chromium FIREHAWK stent with abluminal groove.Methods A total of 21 patients with stable or unstable angina,or prior myocardial infarction,with single de novo native coronary stenoses <30 mm in length in vessel sizes ranging from 2.25 to 4.0 mm were enrolled.The primary endpoint was major adverse cardiac events (MACE) at 30 days defined as the composite of cardiac death,myocardial infarction (Q and non-Q),or ischemia-driven target lesion revascularization.Secondary endpoints include device,lesion,and clinical success rates,4-month in-stent late lumen loss by quantitative coronary angiography (QCA),proportion of uncovered or malapposed stent struts by optical coherence tomograpphy (OCT) at 4 months,and MACE at 4,12,24 and 36-month follow-up.Results Device success was 95.7%,lesion and clinical success was 100.0%.There were no MACE events at 30 days.One patient died of non-cardiac hemorrhagic stroke 5 days after index procedure.At 4 months,in-stent late loss was (0.13±0.18) mm,and complete strut coverage was 96.2% by OCT with 0.1% strut malapposition.At 4-month follow-up there was no additional MACE events,and a single target vessel (non-target lesion) revascularization.Conclusions The FIREHAWK abluminal groove biodegradable polymer rapamycin-eluting stent demonstrated feasibility,safety and efficacy in this first in human experience.OCT findings indicated excellent stent strut coverage 4months after implantation.Larger studies are required to confirm whether the early FIREHAWK stent results translate into longer term restenosis and thrombosis benefits.

  19. Sirolimus-eluting cobalt alloyed stents in treating patients with coronary artery disease: six-month angiographic and one-year clinical follow-up result A prospective, historically controlled, multi-center clinical study

    Institute of Scientific and Technical Information of China (English)

    ZHANG Qi; HONG Tao; CHEN Ji-lin; HUO Yong; SHEN Wei-feng; GAO Run-lin; XU Bo; YANG Yue-jin; ZHANG Rui-yan; LI Jian-ping; QIAO Shu-bin; ZHANG Jian-sheng; HU Jian; QIN Xue-wen

    2007-01-01

    Background The emergence of drug-eluting stents (DES) has dramatically reduced the incidence of in-stent restenosis.This study was conducted to evaluate the safetyand efficacy of sirolimus-eluting cobalt-chrome stents (Firebird 2) for treating patients with coronary artery disease.Methods Sixty-seven patients with de novo or non-stented restenostic coronary lesions were chosen to receive the Firebird 2 stent as the final treatment (Firebird 2 group). Another 49 consecutive patients were implanted with bare cobalt alloyed stents (Driver, Medtronic) withit the previous six months and served as historical controls (control group).Baseline clinical characteristics, angiographic features, procedural results, 30-day, 6-month and 12-month clinical follow-up regarding the occurrence of major adverse cardiac events (MACE), as well as the primary endpoint of late lumen loss at 6-month angiographic follow-up were compared between the two groups.Results The demographic characteristics were similar between the two groups despite more patients in the Firebird 2group who underwent previous percutaneous coronary intervention (22.4% vs 8.2%, P=0.0418) and who had diabetes mellitus (29.9% vs 12.2%, P=0.0253). In the Firebird 2 group, the mean diameter of the reference vessel was smaller((2.79±0.46) mm vs (2.98±0.49) mm, P=0.0175) and more stents were implanted for each lesion (1.28±0.52 vs 1.10±0.30, P=0.0060). Other angiographic, procedural results and the device success rate were similar between the two groups. The MACE rate at 30-day and 3-month was the same, but significantly fewer MACE occurred in the Firebird 2group at 6- and 12-month follow-up (1.5% vs 12.2% at 6 month, P=0.0168; 1.5% vs 26.5% at 12 month, P<0.0001). The primary endpoint of late lumen loss at 6-month angiographic follow-up was significantly reduced in the Firebird 2 group (in-stent: (0.05±0.09) mm vs (0.98±0.61) mm; in-segment: (0.05±0.18) mm vs (0.72±0.59) mm; P<0.0001) than the control group

  20. Development of a rabbit model for a preclinical comparison of coronary stent types in-vivo.

    Science.gov (United States)

    Lee, Joo Myung; Lee, Jaewon; Jeong, Heewon; Choe, Won Seok; Seo, Won-Woo; Lim, Woo-Hyun; Kim, Young-Chan; Hur, Jin; Lee, Sang Eun; Yang, Han-Mo; Cho, Hyun-Jai; Kim, Hyo-Soo

    2013-11-01

    Along with the development of innovative stent designs, preclinical trials in animal models are essential. Many animal models have been used and appear to yield comparable results to clinical trials despite substantial criticisms about their validity. Among the animal models, porcine coronary artery models have been the standard models for the preclinical evaluation of endovascular devices. However, rapid growth rate, high body weight potential, and the propensity to develop granulomatous inflammatory reactions are major limitations of the porcine coronary artery model. Compared with porcine coronary artery models, the comparative rabbit iliac artery model has the advantages of being small and easy to handle and relatively inexpensive. Furthermore, the rabbit model has been known to reliably reflect human restenosis histopathologically and have major advantages such as pairwise comparison, which makes each animal serve as its own control subject, therefore, maximizing its statistical power for comparative testing. However, despite the widespread use of this model, a systematic description of the procedure and harvest protocols has never been published. This article describes the surgical procedure, stent implantation procedure, method for tissue harvesting, and how measurements are performed. Although the results of animal models may not perfectly extrapolate to humans, the comparative rabbit iliac artery model may be a useful tool for assessing and comparing the efficacy of new coronary stents with conventional stent systems. This thorough description of the techniques required for vascular access, stent implantation, tissue preparation, and measurement, should aid investigators wishing to begin using the comparative rabbit iliac artery model.

  1. Coronary aneurysm and very late stent thrombosis formation associated with sirolimus-eluting stent implantation

    Institute of Scientific and Technical Information of China (English)

    XIE Hong-zhi; ZHANG Shu-yang; ZENG Yong; SHEN Zhu-jun; FANG Quan

    2009-01-01

    @@ Since drug-eluting stents (DES) can significantly reduce the risk of instant restenosis compared with bare-metal stents, they have been widely used in interventional therapy for coronary heart disease. With bare-metal stents being rapidly replaced by DES there is a great concern about the safety of DES due to stent thrombosis.~(1,2)

  2. Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials

    DEFF Research Database (Denmark)

    Tanimoto, Shuzou; Serruys, Patrick W; Thuesen, Leif

    2007-01-01

    the antiproliferative drug, everolimus, and expected to be totally metabolized and absorbed in the human body. Because the BVS is made from polymer, it may have more acute recoil than metallic stents in vivo. METHODS: A total of 54 patients, who underwent elective stent implantation for single de novo native coronary...... artery lesions, were enrolled: 27 patients treated with the BVS and 27 patients treated with the everolimus-eluting cobalt chromium stent (EES). Acute absolute recoil, assessed by quantitative coronary angiography, was defined as the difference between mean diameter of the last inflated balloon...

  3. Review of stents for the carotid artery.

    Science.gov (United States)

    Bosiers, M; Deloose, K; Verbist, J; Peeters, P

    2006-04-01

    The individual characteristics of a stent may make it an attractive choice in some circumstances, but render it a less desirable option in others. The applicability depends primarily on the arterial anatomy and the specific details of the lesion being treated. A careful assessment by the interventionalist is required to select the proper type of stent that is of appropriate size. Certainly, personal preferences and familiarity with a specific device may legitimately influence the decision to choose one stent over another. Finally, stent design can play a role in the selection procedure. Although carotid stents are often functionally equivalent in the clinical setting and have been used successfully to treat a wide variety of lesions, a basic knowledge of stent geometry can contribute to make up your mind in certain carotid cases.

  4. Increase of ADAM10 level in coronary artery in-stent restenosis segments in diabetic minipigs: high ADAM10 expression promoting growth and migration in human vascular smooth muscle cells via Notch 1 and 3.

    Directory of Open Access Journals (Sweden)

    Ke Yang

    Full Text Available BACKGROUND: This study aimed to identify major proteins in the pathogenesis of coronary artery in-stent restenosis (ISR in diabetic minipigs with sirolimus-eluting stenting, and to investigate the roles of key candidate molecules, particularly ADAM10, in human arterial smooth muscle cells (HASMCs. METHODS AND RESULTS: The stents were implanted in the coronary arteries of 15 diabetic and 26 non-diabetic minipigs, and angiography was repeated at six months. The intima of one vascular segment with significant ISR and one with non-ISR in diabetic minipigs were isolated and cultured in conditioned medium (CM. The CM was analyzed by LC-MS/MS to uncover proteins whose levels were significantly increased (≥ 1.5-fold in ISR than in non-ISR tissues. After literature searching, we focused on the identified proteins, whose biological functions were most potentially related to ISR pathophysiology. Among them, ADAM10 was significantly increased in diabetic and non-diabetic ISR tissues as compared with non-ISR controls. In cell experiments, retrovirus-mediated overexpression of ADAM10 promoted growth and migration of HASMCs. The effects of ADAM10 were more remarkable in high-glucose culture than in low-glucose culture. Using shRNA and an inhibitor of γ-secretase (GSI, we found that the influences of ADAM10 were in part mediated by Notch1 and notch 3 pathway, which up-regulated Notch downstream genes and enhanced nuclear translocation of the small intracellular component of Notch1 and Notch3. CONCLUSIONS: This study has identified significantly increased expression of ADAM10 in the ISR versus non-ISR segment in diabetic minipigs and implicates ADAM10 in the enhanced neointimal formation observed in diabetes after vascular injury.

  5. [Magnetic resonance compatibility research for coronary mental stents].

    Science.gov (United States)

    Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren

    2015-01-01

    The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.

  6. Drug-eluting stents in the management of peripheral arterial disease.

    Science.gov (United States)

    Bosiers, Marc; Cagiannos, Catherine; Deloose, Koen; Verbist, Jürgen; Peeters, Patrick

    2008-01-01

    Since major meta-analyses of randomized controlled trials in interventional cardiology showed the potential of drug-eluting stents in decreasing restenosis and reintervention rates after coronary artery stenting, one of the next steps in the treatment of arterial occlusive disease is the transfer of the active coating technology towards peripheral arterial interventions. In this manuscript, we aim to provide a literature overview on available peripheral (lower limb, renal, and supra-aortic) drug-eluting stent applications, debate the cost implications, and give recommendations for future treatment strategies.

  7. Safety and efficacy of angioplasty with intracoronary stenting in patients with unstable coronary syndromes. Comparison with stable coronary syndromes

    Directory of Open Access Journals (Sweden)

    Luís C. L. Correia

    2000-06-01

    Full Text Available OBJECTIVE: To assess safety and efficacy of coronary angioplasty with stent implantation in unstable coronary syndromes. METHODS: Retrospective analysis of in-hospital and late evolution of 74 patients with unstable coronary syndromes (unstable angina or infarction without elevation of the ST segment undergoing coronary angioplasty with stent placement. These 74 patients were compared with 31 patients with stable coronary syndromes (stable angina or stable silent ischemia undergoing the same procedure. RESULTS: No death and no need for revascularization of the culprit artery occurred in the in-hospital phase. The incidences of acute non-Q-wave myocardial infarction were 1.4% and 3.2% (p=0.6 in the unstable and stable coronary syndrome groups, respectively. In the late follow-up (11.2±7.5 months, the incidences of these events combined were 5.7% in the unstable coronary syndrome group and 6.9% (p=0.8 in the stable coronary syndrome group. In the multivariate analysis, the only variable with a tendency to significance as an event predictor was diabetes mellitus (p=0.07; OR=5.2; 95% CI=0.9-29.9. CONCLUSION: The in-hospital and late evolutions of patients with unstable coronary syndrome undergoing angioplasty with intracoronary stent implantation are similar to those of the stable coronary syndrome group, suggesting that this procedure is safe and efficacious when performed in unstable coronary syndrome patients.

  8. The stress-strain behavior of coronary stent struts is size dependent.

    Science.gov (United States)

    Murphy, B P; Savage, P; McHugh, P E; Quinn, D F

    2003-06-01

    Coronary stents are used to re-establish the vascular lumen and flow conditions within the coronary arteries; the typical thickness of a stent strut is 100 microm, and average grain sizes of approximately 25 microm exist in stainless steel stents. The purpose of this study is to investigate the effect of strut size on the stress strain behavior of 316 L stainless steel. Other materials have shown a size dependence at the micron size scale; however, at present there are no studies that show a material property size dependence in coronary stents. Electropolished stainless steel stent struts within the size range of 60-500 microm were tensile tested. The results showed that within the size range of coronary stent struts a size dependent stress-strain relationship is required to describe the material. Finite element models of the final phase of fracture, i.e., void growth models, explained partially the reason for this size effect. This study demonstrated that a size based stress-strain relationship must be used to describe the tensile behavior material of 316 L stainless steel at the size scale of coronary stent struts.

  9. Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion

    Directory of Open Access Journals (Sweden)

    James Barr

    2016-01-01

    Full Text Available Giant coronary artery aneurysms are rare clinical entities. We report the case of a 49-year-old man who presented with dyspnoea and exertional chest pain. Investigations confirmed an aneurysmal right coronary artery measuring 4 cm with a fistulous communication to the right atrium. Following right atriotomy, the fistula was oversewn and the aneurysmal right coronary artery ligated at its origin and at several points along its course. A saphenous vein graft was anastomosed to the posterior descending artery. Persistent ventricular fibrillation occurred upon chest closure, attributed to ischaemia following ligation of the aneurysmal coronary artery. Emergent resternotomy and internal defibrillation were successfully performed. The sternum was stented open to reduce right ventricular strain and closed the following day. The patient made an unremarkable recovery. We here address the technical challenges associated with surgical repair of right coronary aneurysms and the physiology and management of potential complications.

  10. Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion

    Science.gov (United States)

    Barr, James; Kourliouros, Antonios

    2016-01-01

    Giant coronary artery aneurysms are rare clinical entities. We report the case of a 49-year-old man who presented with dyspnoea and exertional chest pain. Investigations confirmed an aneurysmal right coronary artery measuring 4 cm with a fistulous communication to the right atrium. Following right atriotomy, the fistula was oversewn and the aneurysmal right coronary artery ligated at its origin and at several points along its course. A saphenous vein graft was anastomosed to the posterior descending artery. Persistent ventricular fibrillation occurred upon chest closure, attributed to ischaemia following ligation of the aneurysmal coronary artery. Emergent resternotomy and internal defibrillation were successfully performed. The sternum was stented open to reduce right ventricular strain and closed the following day. The patient made an unremarkable recovery. We here address the technical challenges associated with surgical repair of right coronary aneurysms and the physiology and management of potential complications. PMID:28018699

  11. Influence of a pressure gradient distal to implanted bare-metal stent on in-stent restenosis after percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Thuesen, Leif

    2007-01-01

    BACKGROUND: Fractional flow reserve predicts cardiac events after coronary stent implantation. The aim of the present study was to assess the 9-month angiographic in-stent restenosis rate in the setting of optimal stenting and a persisting gradient distal to the stent as assessed by a pressure wire...... performed in the target vessel: (1) P(d)/P(a) as distal to the artery as possible (fractional flow reserve per definition); (2) P(d)/P(a) just distal to the stent; (3) P(d)/P(a) just proximal to the stent; and (4) P(d)/P(a) at the ostium. Residual abnormal P(d)/P(a) was defined as a pressure drop between P......(d)/P(a) measured at points 1 and 2. Fractional flow reserve distal to the artery after stenting was significantly lower (0.88+/-0.21 versus 0.97+/-0.05; P

  12. Fully biodegradable coronary stents : progress to date.

    Science.gov (United States)

    Ramcharitar, Steve; Serruys, Patrick W

    2008-01-01

    The limitations of currently available metallic drug-eluting stents have renewed interest in biodegradable stents (BDS). Apart from removing the (offending) foreign material that may potentiate a thrombotic event, BDS have the advantage of avoiding 'full metal jackets,' and thus can preclude subsequent coronary surgery. In addition, they do not interfere with the diagnostic evaluation of non-invasive imaging such as cardiac magnetic resonance and CT. There are now several BDS in development or in clinical trials that incorporate a variety of biodegradable polymer technologies. Two broad categories of materials are generally used: those made from organic biopolymers and those made from corrodible metals. However, to date, none of the materials/stents tested have been able to establish a perfect balance between biocompatibility, the kinetics of degradation needed to maintain mechanical strength to limit recoil, and inflammation. However, studies, such as the ABSORB trial with the everolimus eluting poly-L-lactide stent, which demonstrated comparable restenotic rates with bare metallic stents and a low incidence of major adverse cardiac events (MACE) at 12 months of 3.3%, with only one patient having a non-Q-wave myocardial infarction and no target lesion revascularization, suggest that there has been significant progress with respect to the earlier prototypes. The acute recoil observed could potentially be addressed with the polytyrosine REVA stent currently being evaluated in the RESORB trial, which incorporates a novel locking mechanism within its design. Alternative BDS designs include the combination of an antiproliferative drug with endothelial progenitor cell capturing antibodies to facilitate epithelialization and/or dual eluting having, in addition to the antiproliferative drug, polymeric salicyclic acid to limit inflammation. Compared with biodegradable polymers, there are fewer metals used in the manufacture of BDS. The only metal BDS in trials is the

  13. Acute stent thrombosis after primary percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Clemmensen, Peter; Wiberg, Sebastian; Van't Hof, Arnoud;

    2015-01-01

    OBJECTIVES: This study sought to determine clinical, procedural, and treatment factors associated with acute stent thrombosis (AST) in the EUROMAX (European Ambulance Acute Coronary Syndrome Angiography) trial. BACKGROUND: Bivalirudin started during transport for primary percutaneous coronary int...

  14. Coronary artery anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Malago, Roberto; Pezzato, Andrea; Barbiani, Camilla; Alfonsi, Ugolino; Nicoli, Lisa; Caliari, Giuliana; Pozzi Mucelli, Roberto [Policlinico G.B. Rossi, University of Verona, Department of Radiology, Verona (Italy)

    2011-12-15

    Variants and congenital anomalies of the coronary arteries are usually asymptomatic, but may present with severe chest pain or cardiac arrest. The introduction of multidetector CT coronary angiography (MDCT-CA) allows the detection of significant coronary artery stenosis. Improved performance with isotropic spatial resolution and higher temporal resolution provides a valid alternative to conventional coronary angiography (CCA) in many patients. MDCT-CA is now considered the ideal tool for three-dimensional visualization of the complex and tortuous anatomy of the coronary arteries. With multiplanar and volume-rendered reconstructions, MDCT-CA may even outperform CCA in determining the relative position of vessels, thus providing a better view of the coronary vascular anatomy. The purpose of this review is to describe the normal anatomy of the coronary arteries and their main variants based on MDCT-CA with appropriate reconstructions. (orig.)

  15. Debate over patient-centered care: percutaneous coronary intervention or coronary artery bypass grafting?

    Science.gov (United States)

    Kawasuji, Michio

    2011-04-01

    Coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) have developed as effective therapies to treat coronary artery disease. Initial CABG is associated with lower mortality than initial medical management, especially among high- and intermediate-risk patients with coronary artery disease. However, PCI is currently the most frequent initial treatment delivered by interventional cardiologists to treat multivessel coronary artery disease, despite substantial evidence from meta-analyses of randomized trials and registry data favoring CABG. Recent advancements in PCI did not result in detectable improvements in death or myocardial infarction compared with medical therapy, although significant reductions in target lesions or vessel revascularization were identified after implantation of a drug-eluting stent (DES) rather than a bare-metal stent. The SYNTAX trial compared patients with left main and/or three-vessel coronary artery disease treated with DES or CABG. The results of the trial demonstrated the 1-year inferiority of PCI compared with CABG with respect to major adverse cardiac and cerebrovascular events. Nevertheless, patients with coronary artery disease continue to receive more recommendations for PCI and fewer for CABG than are indicated in the guidelines. A multidisciplinary team approach should be the standard of care when recommending interventions for treating complex coronary artery disease among patients for whom CABG is superior in terms of survival and freedom from reintervention.

  16. Second- and third-generation drug-eluting coronary stents: progress and safety.

    Science.gov (United States)

    Akin, I; Schneider, H; Ince, H; Kische, S; Rehders, T C; Chatterjee, T; Nienaber, C A

    2011-05-01

    Drug-eluting stents (DES) have revolutionized the treatment of coronary artery disease by reducing the rate of in-stent restenosis from 20-40% with bare-metal stent (BMS) to 6-8% with DES. However, with widespread use of DES, safety concerns have risen due to the observation of late stent thrombosis. With this in mind and better understanding of mechanism and pathophysiology of stent thrombosis, the technological platform, especially innovative anti-restenotic agents, polymeric coatings, and stent platforms, improved with newer DES. Two second-generation DES, the Endeavor zotarolimus-eluting stent (ZES) and the Xience-V everolimus-eluting stent (EES), have provided promising results in both randomized controlled trials (SPIRIT and ENDEAVOR) and registries (E-Five, COMPARE) compared with bare-metal stents (BMS) and first-generation DES. Newer third-generation stent technology, especially biodegradable polymers, polymer-free stents, and biodegradable stents on the basis of poly-L-lactide (PLLA) or magnesium, has been evaluated in preclinical and initial clinical trials. However, despite encouraging initial results, long-term data of large-scale randomized trials as well as registries comparing them to currently approved first- and second-generation DES are still lacking.

  17. Coronary CT angiography-derived quantitative markers for predicting in-stent restenosis

    NARCIS (Netherlands)

    Tesche, Christian; De Cecco, Carlo N.; Vliegenthart, Rozemarijn; Duguay, Taylor M.; Stubenrauch, Andrew C.; Rosenberg, Russell D.; Varga-Szemes, Akos; Bayer, Richard R.; Yang, Junjie; Ebersberger, Ullrich; Baguet, Moritz; Jochheim, David; Hoffmann, Ellen; Steinberg, Daniel H.; Chiaramida, Salvatore A.; Schoepf, U. Joseph

    2016-01-01

    Objective: To evaluate quantitative markers derived from coronary CT angiography (coronary CTA) performed prior to percutaneous coronary intervention (PCI) with stent placement for predicting in-stent restenosis (ISR) as defined by quantitative coronary angiography (QCA). Materials and methods: We

  18. Recanalization of an accidentally crushed coronary stent by intravascular ultrasonography catheter entrapment.

    Science.gov (United States)

    Kim, Jae Yun; Lee, Nae-Hee; Cho, Yoon Haeng; Suh, Jon; Seo, Hye-Sun; Kim, Do Hoi; Jeon, Young Woo

    2011-06-01

    Intravascular ultrasonography (IVUS) imaging is a user-friendly technique widely used during coronary interventions. An 80-year-old man was admitted with chest pain, and successful percutaneous coronary intervention was performed with stent implantation. One week later, the patient complained of further chest pain. Urgent coronary angiography showed total occlusion of the middle left anterior descending artery and the aspiration of thrombi was high. IVUS imaging showed inadequate stent strut apposition and distal dissection. We attempted another stent implantation but the IVUS catheter was stuck on the 0.014 inch wire. Therefore, we tried to pass the wire across the lateral side. After the wire was successfully passaged, the sprinter balloon was passed through the crushed stent to expand it. After 4 days later, the patient was discharged with no symptoms or electrocardiographic change.

  19. Association of Coronary Perivascular Adipose Tissue Inflammation and Drug-Eluting Stent-Induced Coronary Hyperconstricting Responses in Pigs: (18)F-Fluorodeoxyglucose Positron Emission Tomography Imaging Study.

    Science.gov (United States)

    Ohyama, Kazuma; Matsumoto, Yasuharu; Amamizu, Hirokazu; Uzuka, Hironori; Nishimiya, Kensuke; Morosawa, Susumu; Hirano, Michinori; Watabe, Hiroshi; Funaki, Yoshihito; Miyata, Satoshi; Takahashi, Jun; Ito, Kenta; Shimokawa, Hiroaki

    2017-09-01

    Although coronary perivascular adipose tissue (PVAT) may play important roles as a source of inflammation, the association of coronary PVAT inflammation and coronary hyperconstricting responses remains to be examined. We addressed this important issue in a porcine model of coronary hyperconstricting responses after drug-eluting stent implantation with (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomographic imaging. An everolimus-eluting stent (EES) was randomly implanted in pigs into the left anterior descending or the left circumflex coronary artery while nonstented coronary artery was used as a control. After 1 month, coronary vasoconstricting responses to intracoronary serotonin (10 and 100 μg/kg) were examined by coronary angiography in vivo, followed by in vivo and ex vivo (18)F-FDG positron emission tomographic/computed tomographic imaging. Coronary vasoconstricting responses to serotonin were significantly enhanced at the EES edges compared with the control site (Pinflammation. © 2017 American Heart Association, Inc.

  20. Spontaneous Coronary Artery Dissection.

    Science.gov (United States)

    Tweet, Marysia S; Gulati, Rajiv; Hayes, Sharonne N

    2016-07-01

    Spontaneous coronary artery dissection is an important etiology of nonatherosclerotic acute coronary syndrome, myocardial infarction, and sudden death. Innovations in the catheterization laboratory including optical coherence tomography and intravascular ultrasound have enhanced the ability to visualize intimal disruption and intramural hematoma associated with SCAD. Formerly considered "rare," these technological advances and heightened awareness suggest that SCAD is more prevalent than prior estimates. SCAD is associated with female sex, young age, extreme emotional stress, or extreme exertion, pregnancy, and fibromuscular dysplasia. The clinical characteristics and management strategies of SCAD patients are different than for atherosclerotic heart disease and deserve specific consideration. This review will highlight recent discoveries about SCAD as well as describe current efforts to elucidate remaining gaps in knowledge.

  1. Computational fluid dynamics evaluation of incomplete stent apposition in a tapered artery

    Science.gov (United States)

    Poon, Eric; Thondapu, Vikas; Ooi, Andrew; Hayat, Umair; Barlis, Peter; Moore, Stephen

    2015-11-01

    Coronary stents are deployed to prop open blocked arteries and restore normal blood flow, however in-stent restenosis (ISR) and stent thrombosis (ST) remain possibly catastrophic complications. Computational fluid dynamics (CFD) analyses can elucidate the pathological impact of alterations in coronary hemodynamics and correlate wall shear stress (WSS) with atherosclerotic processes. The natural tapering of a coronary artery often leads to proximal incomplete stent apposition (ISA) where stent struts are not in contact with the vessel wall. By employing state-of-the-art computer-aided design (CAD) software, generic open-cell and closed-cell coronary stent designs were virtually deployed in an idealised tapered coronary artery. Pulsatile blood flow (80 mL/min at 75 beats/min) was carried out numerically on these CAD models using a finite volume solver. CFD results reveal significant fluctuations in proximal WSS and large recirculation regions in the setting of proximal ISA, resulting in regions of high wall shear stress gradient (WSSG) that have been previously linked to poor endothelial cell coverage and vascular injury. The clinical significance of these proximal high WSSG regions will be correlated with findings from high-resolution in-vivo imaging. Supported by the Australian Research Council (LP120100233) and Victorian Life Sciences Computation Initiative (VR0210).

  2. Simultaneous occlusion of left anterior descending and left circumflex arteries by very late stent thrombosis: vascular response to drug-eluting stents assessed by intravascular ultrasound.

    Science.gov (United States)

    Yamawaki, Masahiro; Onuma, Yoshinobu; Nakano, Masatsugu; Muramatsu, Takashi; Nakatani, Shimpei; Ishibashi, Yuki; Ishimori, Hiroshi; Hirano, Keisuke; Ito, Yoshiaki; Tsukahara, Reiko; Muramatsu, Toshiya

    2015-11-01

    Very late stent thrombosis (VLST) is a catastrophic complication after implantation of a drug-eluting stent (DES). It has been reported that VLST is associated with pathological changes, which often include late acquired incomplete stent apposition (LAISA) with thrombus formation. In addition, the vascular response to the stent (evaginations, neointimal growth, and thrombosis) and the incidence of LAISA are reported to vary among the different types of DES. We experienced a patient with cardiogenic shock induced by simultaneous VLST of both the left anterior descending artery (LAD) and the left circumflex artery (LCX) at 3 years after implantation of two sirolimus-eluting stents. Intravascular ultrasound (IVUS) showed LAISA of both arteries. A paclitaxel-eluting stent, which had been implanted in the right coronary artery 3 years earlier, did not show such a finding. IVUS revealed "different vascular reactions" to "different types of DES" in this patient.

  3. Emergency coronary artery bypass surgery after failed percutaneous coronary intervention.

    Science.gov (United States)

    Darwazah, A K; Islim, I; Hanbali, B; Shama, R A; Aloul, J

    2009-12-01

    The incidence of patients subjected to emergency coronary artery bypass graft (CABG) after percutaneous coronary intervention (PCI) is decreasing due to improvement of PCI technique and device technology. The aim of our study is to evaluate cases subjected to emergency CABG after complicated PCI to determine incidence, indications and results of surgery and to compare them with other emergency cases which are not related to angioplasty or stenting. From April 1999 to December 2005, 1 200 patients who underwent PCI were analysed. Those patients who developed complications related to PCI and required surgical intervention were included (PCI group N.=31). These patients were compared with other emergency cases not related to PCI (non-PCI group N.=48). The selection of these patients was based on the criteria of the Society of Thoracic Surgeons. The incidence of PCI complications which necessitated emergency surgical intervention was 2.6%. The main indication was due to unsatisfactory angioplasty with ongoing myocardial ischemia (68%), stent thrombosis (13%), dissection (10%) retained angioplasty wire (6.5%), and perforation (3%). The incidence of cardiogenic shock, ongoing ischemia, acute infarction Emergency coronary artery bypass grafting among patients with PCI complications and those patients not related to PCI is associated with high mortality and morbidity. Although, the percentage of mortality and morbidity was more among PCI patients the difference between both groups was not significant. Surgical backup and collaboration between cardiologist and surgeons is needed to reduce delay in management and patients transfer to obtain the best surgical outcome.

  4. Detailing Radio Frequency Heating Induced by Coronary Stents: A 7.0 Tesla Magnetic Resonance Study

    OpenAIRE

    Davide Santoro; Lukas Winter; Alexander Müller; Julia Vogt; Wolfgang Renz; Celal Ozerdem; Andreas Grässl; Valeriy Tkachenko; Jeanette Schulz-Menger; Thoralf Niendorf

    2012-01-01

    The sensitivity gain of ultrahigh field Magnetic Resonance (UHF-MR) holds the promise to enhance spatial and temporal resolution. Such improvements could be beneficial for cardiovascular MR. However, intracoronary stents used for treatment of coronary artery disease are currently considered to be contra-indications for UHF-MR. The antenna effect induced by a stent together with RF wavelength shortening could increase local radiofrequency (RF) power deposition at 7.0 T and bears the potential ...

  5. Coronary arterial complications after percutaneous coronary intervention in Behçet’s disease

    Directory of Open Access Journals (Sweden)

    Kinoshita T

    2013-02-01

    Full Text Available Toshio Kinoshita,1 Shinichiro Fujimoto,1 Yukio Ishikawa,2 Hitomi Yuzawa,1 Shunji Fukunaga,1 Mikihito Toda,3 Kenji Wagatsuma,3 Yoshikiyo Akasaka,2 Toshiharu Ishii,2 Takanori Ikeda11Department of Cardiovascular Medicine, 2Department of Pathology, 3Division of Interventional Cardiology, Toho University Faculty of Medicine, Ohta City, Tokyo, JapanAbstract: Behçet’s disease is a multisystemic vascular inflammatory disease, but concurrent cardiac diseases, such as acute myocardial infarction, are rare. Several complications may arise after coronary intervention for coronary lesions that interfere with treatment, and the incidence of coronary arterial complications due to invasive therapy remains unclear. Further, the long-term outcomes in patients with Behçet’s disease after stenting for acute myocardial infarction have not been described. The present report describes a 35-year-old Japanese man with Behçet’s disease who developed acute myocardial infarction. A coronary aneurysm developed at the stenting site of the left anterior descending coronary artery, along with stenosis in the left anterior descending segment proximal to the site. Although invasive therapy was considered, medication including immunosuppressants was selected because of the high risk of vascular complications after invasive therapy. The coronary artery disease has remained asymptomatic for the 4 years since the patient started medication. This case underscores the importance of considering the incidence of coronary arterial complications and of conservative treatment when possible.Keywords: Behçet’s disease, myocardial infarction, coronary arterial complications, percutaneous coronary intervention, immunosuppressants

  6. Incidence of definite stent thrombosis or in-stent restenosis after drug-eluting stent implantation for treatment of coronary in-stent restenosis

    DEFF Research Database (Denmark)

    Jensen, Jesper Khedri; Jensen, Lisette Okkels; Terkelsen, Christian Juhl;

    2013-01-01

    There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis...

  7. Current status of coronary artery bypass surgery

    Institute of Scientific and Technical Information of China (English)

    CHEN Xin

    2009-01-01

    @@ Surgical revascularization for atherosclerotic heart disease, also called coronary artery bypass grafting (CABG), was first performed in 1962, and is one of the great achievements in medicine. Relief of angina, improvement of exercise tolerance, and the realization of survival benefit have been documented.1 CABG has been used in multi-vessel disease and left main stenosis for over 40 years.2 In the last two decades the mortality of CABG has decreased to less than 2% despite an aging population with increased risk factors. However, percutaneous coronary intervention (PCI), especially with drug-eluting stents, has been challenging CABG, While PCI has improved, CABG has also progressed with better peri-operative management, a higher use of arterial grafting, off-pump surgery, and improved techniques with minimally invasive surgical options.3,4

  8. Coronary perforation and covered stents: An update and review

    Directory of Open Access Journals (Sweden)

    Mohammed Al-Mukhaini

    2011-01-01

    Full Text Available Coronary perforation is a rare complication of percutaneous coronary intervention. We present two different types of coronary intervention, but both ending with coronary perforation. However, these perforations were tackled successfully by covered stents. This article reviews the incidence, causes, presentation, and management of coronary perforation in the present era of aggressive interventional cardiology. Coronary perforations are classified as type I (extraluminal crater, II (myocardial or pericardial blushing, and III (contrast streaming or cavity spilling. Types I and II coronary perforations are caused by stiff or hydrophilic guidewires. Type I has a benign prognosis, whereas type II coronary perforations have the potential to progress to tamponade. Type III coronary perforations are caused by balloons, stents, or other intracoronary devices and commonly lead to cardiac tamponade necessitating pericardial drainage. However, type III perforations can be managed with covered stents without need for surgical intervention.

  9. Frequency of Angina Pectoris After Percutaneous Coronary Intervention and the Effect of Metallic Stent Type.

    Science.gov (United States)

    Gaglia, Michael A; Torguson, Rebecca; Lipinski, Michael J; Gai, Jiaxiang; Koifman, Edward; Kiramijyan, Sarkis; Negi, Smita; Rogers, Toby; Steinvil, Arie; Suddath, William O; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-02-15

    Although metallic coronary stents significantly reduce angina pectoris compared with optimal medical therapy, angina after percutaneous coronary intervention (PCI) remains frequent. We, therefore, sought to compare the incidence of any angina during the 1 year after PCI among the spectrum of commercially available metallic stents. Metallic stent type was classified as bare metal stent, Cypher, Taxus Express, Xience V, Promus Element, and Resolute. The primary end point was patient-reported angina within 1 year of PCI. Multivariable logistic regression was performed to assess the independent association of stent type with any angina at 1 year. Overall, 8,804 patients were queried in regard to angina symptoms; 32.3% experienced angina at some point in the first year after PCI. Major adverse cardiovascular events, a composite of all-cause mortality, target vessel revascularization, and Q-wave myocardial infarction, increased with angina severity: 6.8% for patients without angina, 10.0% for patients with class 1 or 2 angina, and 19.7% for patients with class 3 or 4 angina (p angina at 1 year after PCI. Baseline Canadian Cardiovascular Society class 3 or 4 angina, history of coronary artery bypass grafting, and history of PCI were associated with a higher likelihood of angina at 1 year; increasing age, male gender, presentation with acute coronary syndrome, and higher stented length were associated with less angina. In conclusion, metallic stent type is not associated with the occurrence of angina at up to 1 year after PCI.

  10. 雷帕霉素与紫杉醇洗脱支架置入治疗冠状动脉病变的有效性%Efficacy of rapamycin and paclitaxel eluting stent implantation in treatment of coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    杨俊; 陈冬林; 陈银朝; 陈新敬

    2015-01-01

    背景:药物洗脱支架置入治疗冠状动脉病变具有良好的临床效果,但不同支架的治疗效果可能存在一定差异。目的:比较不同支架置入治疗冠状动脉病变的临床效果。方法:纳入278例冠状动脉病变患者,均接受冠状动脉支架置入治疗,其中91例置入雷帕霉素洗脱支架,92例置入紫杉醇洗脱支架,95例置入裸金属支架。支架置入后随访12个月,记录死亡和心肌梗死等不良心脏事件发生情况,以及冠状动脉再狭窄发生情况及材料宿主反应。结果与结论:雷帕霉素洗脱支架组与紫杉醇洗脱支架组冠状动脉再狭窄率、急性心肌梗死发生率、冠状动脉旁路移植或再次经皮冠状动脉介入治疗率均低于裸金属支架组(P0.05)。3组死亡率比较差异无显著性意义(P>0.05)。3组均未发生支架移位、脱落、断裂、置入位置不良及白细胞增多和血小板减少、溶血等情况。表明两种药物洗脱支架的治疗效果相当,均优于裸金属支架。%BACKGROUND: The clinical effect of drug-eluting stent implantation in treatment of coronary artery disease is good, but there may be some differences in the therapeutic effect between different stents. OBJECTIVE:To compare the clinical effect of different stent implantation in treatment of coronary artery disease. METHODS:A total of 278 patients with coronary artery disease were enroled and al underwent coronary artery stent implantation treatment, of which 91 patients underwent implanted rapamycin eluting stent, 92 patients underwent implanted paclitaxel eluting stent, and 95 patients underwent implanted bare metal stents. Al the patients were folowed up for 12 months after stents implantation. The occurrence of adverse cardiac events such as death, myocardial infarction, and the occurrence of coronary restenosis and host reaction were recorded. RESULTS AND CONCLUSION:The rates of coronary artery stenosis, acute

  11. Coronary Artery Disease - Coronary Heart Disease

    Science.gov (United States)

    ... result of coronary artery disease, or CAD, said Edward A. Fisher, M.D., Ph.D., M.P. ... Problems and Disease • High Blood Pressure (HBP) • Metabolic Syndrome • Pericarditis • Peripheral Artery Disease (PAD) • Stroke • Vascular Health • ...

  12. 5公里快走对冠心病支架术后患者抑郁状态的影响%Effect of 5-km brisk walking on depression among patients with coronary artery disease after stenting

    Institute of Scientific and Technical Information of China (English)

    李十红; 陈玄祖; 高云; 孙俊平; 张京梅; 李志忠

    2014-01-01

    目的:观察有氧运动5公里快走对行冠心病支架治疗患者术后抑郁状态的影响。方法入选69例冠心病支架术后抑郁状态的患者,观察组39例进行运动干预,5公里有氧运动,每周5次,每次50~60 min;对照组30例服用抗忧郁药。干预6个月复查抑郁量表变化。结果冠心病支架术后从事有氧运动积极有效,5公里快走可以明显改善抑郁状态,某些指标优于抗抑郁药物。结论有氧运动5公里快走有利于冠心病支架治疗患者术后抑郁状态的改善,安全可靠,简便易行,可操作性强易于掌握,比抗忧郁药物有优势。%Objective To observe the effect of aerobic exercise 5-km brisk walking on the depression for patients with coronary artery disease after stenting Method A total of 69 patients after coronary stenting with depres-sion were included and divided into 2 groups:the observation group(n=39),the patients were intervened by aerobic exercise5-km brisk-walking,5 times a week,50-60 mineach time,the control group(n=30),patients were treated with antidepressants .The changes in indexes of depression scale were observed after 6-mon intervention .Results The aerobic exercise of 5-km brisk walking in patients after coronary stenting can significantly improve the depression , which works better in some indicators than antidepressants treatment .Conclusion Aerobic exercise 5 km away to im-prove depression for coronary stent in the treatment of patients depression is simple ,safe and reliable ,strong operabili-ty and easy to master with some have advantage than antidepressants .

  13. Clinical and economic studies of eptifibatide in coronary stenting

    Directory of Open Access Journals (Sweden)

    Pasala T

    2014-08-01

    Full Text Available Tilak Pasala, Prasongchai Sattayaprasert, Pradeep K Bhat, Ganesh Athappan, Sanjay Gandhi The Heart and Vascular Center, Case Western Reserve University/MetroHealth, Cleveland, OH, USA Abstract: Platelet adhesion and aggregation at the site of coronary stenting can have catastrophic clinical and economic consequences. Therefore, effective platelet inhibition is vital during and after percutaneous coronary intervention. Eptifibatide is an intravenous antiplatelet agent that blocks the final common pathway of platelet aggregation and thrombus formation by binding to glycoprotein IIb/IIIa receptors on the surface of platelets. In clinical studies, eptifibatide was associated with a significant reduction of mortality, myocardial infarction, or target vessel revascularization in patients with acute coronary syndrome undergoing percutaneous coronary intervention. However, recent trials conducted in the era of dual antiplatelet therapy and newer anticoagulants failed to demonstrate similar results. The previously seen favorable benefit of eptifibatide was mainly offset by the increased risk of bleeding. Current American College of Cardiology/American Heart Association guidelines recommend its use as an adjunct in high-risk patients who are undergoing percutaneous coronary intervention with traditional anticoagulants (heparin or enoxaparin, who are not otherwise at high risk of bleeding. In patients receiving bivalirudin (a newer safer anticoagulant, routine use of eptifibatide is discouraged except in select situations (eg, angiographic complications. Although older pharmacoeconomic studies favor eptifibatide, in the current era of P2Y12 inhibitors and newer safer anticoagulants, the increased costs associated with bleeding make the routine use of eptifibatide an economically nonviable option. The cost-effectiveness of eptifibatide with the use of strategies that decrease the bleeding risk (eg, transradial access is unknown. This review provides an

  14. Vertebral artery origin stenting with buddy wire technique in tortuous subclavian artery

    Energy Technology Data Exchange (ETDEWEB)

    Kizilkilic, Osman [Baskent University Department of Radiology, Adana Teaching and Medical Research Center, 01170 Yuregir-Adana (Turkey)]. E-mail: ebos90@hotmail.com

    2007-01-15

    Catheterization of vessels with severe tortuosity and atherosclerotic changes may represent a technical challenge and is associated with a higher incidence of vascular complications [Putman CM, Chaloupka JC. Use of large-caliber coronary guiding catheters for neurointerventional applications. AJNR Am J Neuroradiol 1996;17:697-704]. Placement of guiding catheter to the tortuous subclavian artery in vertebral artery origin stenting procedure is such a condition with difficulties. In the presence of severe tortuosity of aortic arch and proximal subclavian artery placement of guiding catheter may be difficult and yield poor backup support. We describe a technique that uses a buddy wire to make the guiding catheter stable in its proper position and make possible to perform stenting the vertebral artery origin stenosis.

  15. Bioresorbable scaffolds in the treatment of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Zhang Y

    2013-03-01

    Full Text Available Yaojun Zhang,1,2 Christos V Bourantas,1 Vasim Farooq,1 Takashi Muramatsu,1 Roberto Diletti,1 Yoshinobu Onuma,1 Hector M Garcia-Garcia,1 Patrick W Serruys11Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands; 2Division of Cardiovascular Diseases, Nanjing First Hospital, Nanjing Medical University, Nanjing, People's Republic of ChinaAbstract: Drug-eluting stents have reduced the risk of in-stent restenosis and have broadened the application in percutaneous coronary intervention in coronary artery disease. However, the concept of using a permanent metallic endovascular device to restore the patency of a stenotic artery has inherited pitfalls, namely the presence of a foreign body within the artery causing vascular inflammation, late complications such as restenosis and stent thrombosis, and impeding the restoration of the physiologic function of the stented segment. Bioresorbable scaffolds (BRS were introduced to potentially overcome these limitations, as they provide temporary scaffolding and then disappear, liberating the treated vessel from its cage. Currently, several BRSs are available, undergoing evaluation either in clinical trials or in preclinical settings. The aim of this review is to present the new developments in BRS technology, describe the mechanisms involved in the resorption process, and discuss the potential future prospects of this innovative therapy.Keywords: bioresorbable scaffold, drug-eluting stent, biodegradable, design, mechanism, coronary artery disease

  16. Impact of previous percutaneous transluminal coronary angioplasty and/or stenting revascularization on outcomes after surgical revascularization : insights from the imagine study

    NARCIS (Netherlands)

    Chocron, Sidney; Baillot, Richard; Rouleau, Jean Lucien; Warnica, Wayne J.; Block, Pierre; Johnstone, David; Myers, Martin G.; Calciu, Cristina Dana; Nozza, Anna; Martineau, Pierre; van Gilst, Wiek H.

    2008-01-01

    Aim To determine the impact of previous coronary artery revascularization by percutaneous transluminal coronary angioplasty and/or stenting (PCI) on outcome after subsequent coronary artery bypass grafting (CABG). Methods and results The ischaemia management with Accupril post-bypass Graft via Inhib

  17. Potential role of Chinese medicinal herbs in the prevention of coronary artery restenosis

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ Percutaneous coronary intervention (PCI) especially stent implantation has now become a mainstay of therapeutic armamentarium in the treatment of patients with coronary artery disease even at clinically or angiographically high risk. However, restenosis requiring reintervention remains a major limitation and a challenging problem of percutaneous revascularization. 1 Despite the use of coronary stents, the rate of restenosis is still relatively high, affecting a quarter or more of overall patients treated by bare- metal stents and around 10% of those treated by drug- eluting stents, which may be even higher for complex PCI (long lesion, bifurcation, small vessel disease) or at unfavorable clinical conditions (diabetes, chronic renal failure). 2,3

  18. Drug delivery patterns for different stenting techniques in coronary bifurcations: a comparative computational study.

    Science.gov (United States)

    Cutrì, Elena; Zunino, Paolo; Morlacchi, Stefano; Chiastra, Claudio; Migliavacca, Francesco

    2013-08-01

    The treatment of coronary bifurcation lesions represents a challenge for the interventional cardiologists due to the lower rate of procedural success and the higher risk of restenosis. The advent of drug-eluting stents (DES) has dramatically reduced restenosis and consequently the request for re-intervention. The aim of the present work is to provide further insight about the effectiveness of DES by means of a computational study that combines virtual stent implantation, fluid dynamics and drug release for different stenting protocols currently used in the treatment of a coronary artery bifurcation. An explicit dynamic finite element model is developed in order to obtain realistic configurations of the implanted devices used to perform fluid dynamics analysis by means of a previously developed finite element method coupling the blood flow and the intramural plasma filtration in rigid arteries. To efficiently model the drug release, a multiscale strategy is adopted, ranging from lumped parameter model accounting for drug release to fully 3-D models for drug transport to the artery. Differences in drug delivery to the artery are evaluated with respect to local drug dosage. This model allowed to compare alternative stenting configurations (namely the Provisional Side Branch, the Culotte and the Inverted Culotte techniques), thus suggesting guidelines in the treatment of coronary bifurcation lesions and addressing clinical issues such as the effectiveness of drug delivery to lesions in the side branch, as well as the influence of incomplete strut apposition and overlapping stents.

  19. Short- and long- term health related quality-of-life and anginal status after randomisation to coronary stenting versus bypass surgery for the treatment of multivessel disease

    DEFF Research Database (Denmark)

    van Domburg, Ron T; Daemen, Joost; Pedersen, Susanne S.

    2008-01-01

    Background: Health related quality-of-life (HRQL) beyond one year of treatment of multivessel coronary artery disease with stenting or coronary artery bypass grafting (CABG) is yet unknown. The Arterial Revascularisation Therapy Study (ARTS) was designed to compare CABG and stenting in multivessel...... and anginal status. Although there was a trend for better HRQL after CABG up to one year, the disparity between the two procedures decreased long-term. Most of the difference between the two procedures was attributed to repeat interventions in the stent group; at three years, 19% of stent patients versus 13...

  20. Robotics and coronary artery surgery.

    Science.gov (United States)

    Magee, Mitchell J; Mack, Michael J

    2002-11-01

    Significant progress in cardiac surgery, and specifically the surgical management of coronary artery disease, has been due in large part to enabling technology. Robotic systems have been recently developed and refined for use in cardiac surgery to facilitate, among other procedures, a totally endoscopic approach to coronary artery bypass surgery. These systems enhance precision through endoscopic approaches by specifically addressing the inherent limitations of conventional endoscopic coronary microsurgical instrumentation via computerized, digital interface, telemanipulation technology. With a combined experience of 125 patients, several groups have independently demonstrated the clinical feasibility of totally endoscopic coronary artery bypass with two commercially available robotic telemanipulation systems. Additional enabling technology is needed to overcome the challenges currently limiting development and widespread application of totally endoscopic off-pump multivessel coronary artery bypass surgery.

  1. Stent treatment of symptomatic intracranial arterial stenosis

    Directory of Open Access Journals (Sweden)

    DONG Feng-ju

    2012-08-01

    Full Text Available Objective To investigate the safety, feasibility and efficacy of the Wingspan stent in treatment of symptomatic intracranial arterial stenosis. Methods Wingspan stenting was applied in 90 cases with symptomatic intracranial arterial stenosis. The surgical success rate and periprocedural neurological complications were observed. Digital subtraction angiography was performed at 6 months after stenting to detect the occurrence of restenosis. Results The technical success rate was 98.92% (92/93. Pre-treatment stenosis (83.42 ± 9.53% was improved to (21.82 ± 9.86% after stent placement. The difference was statistically significant (t = 3.280, P = 0.002. There were 5 patients (5.56% occurred major periprocedural neurological complications, 3 of them died within 30 days after the procedure. The restenosis rate at 6 months after operation was 19.10% (17/89. Conclusion Symptomatic intracranial arterial stenosis can be treated by Wingspan stenting with high technical success rate. The occurrence of complication is low and short-term efficacy is good. However, further study is needed to investigate long-term effect.

  2. Emerging Stent and Balloon Technologies in the Femoropopliteal Arteries

    Directory of Open Access Journals (Sweden)

    Georgios Pastromas

    2014-01-01

    Full Text Available Endovascular procedures for the management of the superficial femoral (SFA and popliteal artery disease are increasingly common. Over the past decade, several stent technologies have been established which may offer new options for improved clinical outcomes. This paper reviews the current evidence for SFA and popliteal artery angioplasty and stenting, with a focus on randomized trials and registries of nitinol self-expanding stents, drug-eluting stents, dug-coated balloons, and covered stent-grafts. We also highlight the limitations of the currently available data and the future routes in peripheral arterial disease (PAD stent and balloon technology.

  3. Carotid artery stenting : a 2009 update

    NARCIS (Netherlands)

    Zeebregts, Clark J.; Meerwaldt, Robbert; Geelkerken, Robert H.

    2009-01-01

    Purpose of review Carotid endarterectomy (CEA) is is still considered the gold standard in the treatment of patients with significant carotid stenosis and has proven its value over the past decades. Endovascular techniques have evolved, and carotid artery stenting (CAS) is challenging CEA to become

  4. Coronary CT angiography in coronary artery disease: Opportunities and challenges

    Directory of Open Access Journals (Sweden)

    Zhonghua Sun

    2016-06-01

    Full Text Available Coronary CT angiography is widely recognised as a reliable imaging modality for the diagnosis of coronary artery disease. Coronary CT angiography not only provides excellent visualisation of anatomical changes in the coronary artery with high diagnostic value in the detection of lumen stenosis or occlusion, but also offers quantitative characterisation of coronary plaque components. Furthermore, coronary CT angiography allows myocardial perfusion imaging with diagnostic value comparable to the reference standard method. Coronary CT angiography-derived haemodynamic analysis has the potential to evaluate functional significance of coronary lesions. This review article aims to provide an overview of clinical applications of coronary CT angiography in coronary artery disease.

  5. A review on fracture prevention of stent in femoropopliteal artery

    Science.gov (United States)

    Atan, Bainun Akmal Mohd; Ismail, Al Emran; Taib, Ishkrizat; Lazim, Zulfaqih

    2017-01-01

    Heavily calcific lesions, total occlusions, tortuous blood vessels, variable lengths of arteries, various dynamic loads and deformations in the femoropopliteal (FP) arterial segment make stenosis treatments are complicated. The dynamic forces in FP artery including bending, torsion and radial compression may lead to stent fracture (SF) and eventually to in-stent restenosis (ISR). Stent design specifically geometrical configurations are a major factor need to be improved to optimize stent expansion and flexibility both bending and torsion during stent deployment into the diseased FP artery. Previous studies discovered the influence of various stent geometrical designs resulted different structural behaviour. Optimizing stent design can improve stent performances: flexibility and radial strength to prevent SF in FP arterial segment

  6. Stented artery biomechanics and device design optimization.

    Science.gov (United States)

    Timmins, Lucas H; Moreno, Michael R; Meyer, Clark A; Criscione, John C; Rachev, Alexander; Moore, James E

    2007-05-01

    The deployment of a vascular stent aims to increase lumen diameter for the restoration of blood flow, but the accompanied alterations in the mechanical environment possibly affect the long-term patency of these devices. The primary aim of this investigation was to develop an algorithm to optimize stent design, allowing for consideration of competing solid mechanical concerns (wall stress, lumen gain, and cyclic deflection). Finite element modeling (FEM) was used to estimate artery wall stress and systolic/diastolic geometries, from which single parameter outputs were derived expressing stress, lumen gain, and cyclic artery wall deflection. An optimization scheme was developed using Lagrangian interpolation elements that sought to minimize the sum of these outputs, with weighting coefficients. Varying the weighting coefficients results in stent designs that prioritize one output over another. The accuracy of the algorithm was confirmed by evaluating the resulting outputs of the optimized geometries using FEM. The capacity of the optimization algorithm to identify optimal geometries and their resulting mechanical measures was retained over a wide range of weighting coefficients. The variety of stent designs identified provides general guidelines that have potential clinical use (i.e., lesion-specific stenting).

  7. Rapid development of late stent malappositon and coronary aneurysm following implantation of a paclitaxel-eluting coronary stent

    Institute of Scientific and Technical Information of China (English)

    ZHANG Feng; QIAN Ju-ying; GE Jun-bo

    2007-01-01

    @@ Late stent malapposition (LSM), an unusual intravascular ultrasound (IVUS) finding at follow-up, has been reported to be more common after drug-eluting stent (DES) implantation than after bare metal stent(BMS) implantation.1-3 However, there has been no clear elucidation of time course and mechanism. We reported a case who developed LSM and coronary aneurysm very early after paclitaxel-eluting stent (PES) implantation. A review of the literature reveals no previous report describing rapid development of LSM and coronary aneurysm after PES implantation.

  8. Successful percutaneous transluminal angioplasty and stenting for symptomatic intracranial vertebral artery stenosis using intravascular ultrasound virtual histology.

    Science.gov (United States)

    Takayama, Katsutoshi; Taoka, Toshiaki; Nakagawa, Hiroyuki; Myouchin, Kaoru; Wada, Takeshi; Sakamoto, Masahiko; Fukusumi, Akio; Iwasaki, Satoru; Kurokawa, Shinichiro; Kichikawa, Kimihiko

    2007-06-01

    This is the first report of percutaneous transluminal angioplasty (PTA) of an intracranial artery applying intravascular ultrasound virtual histology (IVUS-VH), which has been recently developed for tissue characterization of coronary artery plaque. We report a case of successful PTA and stenting for symptomatic intracranial vertebral artery stenosis using IVUS-VH.

  9. Preventive role of palladium-103 radioactive stent on in-stent restenosis in rabbit iliac arteries

    Institute of Scientific and Technical Information of China (English)

    LUO Quan-Yong; CHEN Li-Bo; YUAN Zhi-Bin; LU Han-Kui; ZHU Rui-Sen

    2005-01-01

    The abilility of γ-emitting palladium-103 stent implantation to inhibit in-stent restenosis in rabbit iliac arteries was investigated. Quantitative histomorphometry of the stented iliac segments 28 days after the implantation indicated that palladium-103 stents made a significant reduction in neointimal area and percent area stenosis compared with the nonradioactive stents. Lumen area in the palladium-103 stents treatment group was larger than the control group. However, the reduction of neointima formation by palladium-103 stents implantation was in a non-dose-dependent fashion. Low ionizing radiation doses via γ-emitting palladiurn-103 stent are effective in preventing neointimal hyperplasia in iliac arteries of rabbits. Palladium-103 stents can be employed as a possible novel means to prevent in-stent restenosis.

  10. Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials.

    Science.gov (United States)

    Tanimoto, Shuzou; Serruys, Patrick W; Thuesen, Leif; Dudek, Dariusz; de Bruyne, Bernard; Chevalier, Bernard; Ormiston, John A

    2007-10-01

    This study sought to evaluate and compare in vivo acute stent recoil of a novel bioabsorbable stent and a metallic stent. The bioabsorbable everolimus-eluting coronary stent (BVS) is composed of a poly-L-lactic acid backbone, coated with a bioabsorbable polymer containing the antiproliferative drug, everolimus, and expected to be totally metabolized and absorbed in the human body. Because the BVS is made from polymer, it may have more acute recoil than metallic stents in vivo. A total of 54 patients, who underwent elective stent implantation for single de novo native coronary artery lesions, were enrolled: 27 patients treated with the BVS and 27 patients treated with the everolimus-eluting cobalt chromium stent (EES). Acute absolute recoil, assessed by quantitative coronary angiography, was defined as the difference between mean diameter of the last inflated balloon at the highest pressure (X) and mean lumen diameter of the stent immediately after the last balloon deflation (Y). Acute percent recoil was defined as (X - Y)/X and expressed as a percentage. Acute absolute recoil of the BVS and EES was 0.20 +/- 0.21 mm and 0.13 +/- 0.21 mm, respectively (P = 0.32). Acute percent recoil was 6.9% +/- 7.0% in the BVS group and 4.3% +/- 7.1% in the EES group (P = 0.25). In vivo acute stent recoil of the BVS is slightly larger but insignificantly different from that of the EES, implying that the BVS may have good radial strength similar to the metallic stent. (c) 2007 Wiley-Liss, Inc.

  11. Anomalous origin of right coronary artery from pulmonary artery

    Directory of Open Access Journals (Sweden)

    Rajat Gupta

    2012-01-01

    Full Text Available Anomalous origin of coronary artery from the pulmonary artery is a rare anomaly that most frequently involves the left coronary artery and very rarely the right coronary artery. These lesions can be missed on echocardiography unless carefully looked for. We describe a case of isolated anomalous origin of right coronary artery from pulmonary artery diagnosed on echocardiography and confirmed by computed tomography (CT angiography.

  12. Adenosine triphosphate stress 99mTc-methoxyisobutylisonitrile gated myocardial perfusion imaging efficacy in diagnosing stent restenosis following coronary stent implantation

    Science.gov (United States)

    Zhang, Pengfei; Chen, Song; Li, Yang; Du, Qiuhong; Wang, Lijuan; Sun, Yingxian; Li, Yaming

    2016-01-01

    Coronary stent restenosis rate following implantation is considerably high. The adenosine stress gated myocardial perfusion imaging (G-MPI) method has been widely used in the diagnosis, risk stratification and prognosis evaluation of coronary heart disease; however, the high cost of adenosine limits its clinical application. The aim of the present study was to investigate the efficacy of adenosine triphosphate (ATP) stress 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) G-MPI for diagnosis in-stent restenosis following coronary stent implantation. Data from 66 patients with typical angina pectoris symptoms who had undergone percutaneous coronary stent implantation >3 months prior to participation in the study were analyzed. All the patients underwent ATP stress 99mTc-MIBI G-MPI and coronary artery angiography as the criterion diagnostic standard within 1 month. The sensitivity, specificity, and accuracy of ATP stress 99mTc-MIBI G-MPI in the assessment of in-stent restenosis were calculated. In addition, Fisher's exact probability methods were used to compare differences between experimental groups. Among 66 patients with a total of 99 implanted coronary arterial branches, 39 patients (59%) with 45 coronary arteries (45%) presented in-stent restenosis. The diagnostic sensitivity, specificity, accuracy, positive predictive and negative predictive value of ATP stress 99mTc-MIBI G-MPI for assessing stent restenosis in all patients were 85, 89, 86, 92 and 80%, respectively. Similarly, these values in patients with myocardial infarction were 79, 88, 83, 88 and 78%, respectively, while in patients without myocardial infarction the values were 90, 91, 90, 95 and 83%, respectively. Therefore, the diagnostic efficacy of ATP stress 99mTc-MIBI G-MPI in patients without myocardial infarction was higher compared with those with myocardial infarction; however, no significant difference was observed between the two groups. Furthermore, the sensitivity, specificity and accuracy for

  13. Adenosine triphosphate stress (99m)Tc-methoxyisobutylisonitrile gated myocardial perfusion imaging efficacy in diagnosing stent restenosis following coronary stent implantation.

    Science.gov (United States)

    Zhang, Pengfei; Chen, Song; Li, Yang; Du, Qiuhong; Wang, Lijuan; Sun, Yingxian; Li, Yaming

    2016-12-01

    Coronary stent restenosis rate following implantation is considerably high. The adenosine stress gated myocardial perfusion imaging (G-MPI) method has been widely used in the diagnosis, risk stratification and prognosis evaluation of coronary heart disease; however, the high cost of adenosine limits its clinical application. The aim of the present study was to investigate the efficacy of adenosine triphosphate (ATP) stress (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) G-MPI for diagnosis in-stent restenosis following coronary stent implantation. Data from 66 patients with typical angina pectoris symptoms who had undergone percutaneous coronary stent implantation >3 months prior to participation in the study were analyzed. All the patients underwent ATP stress (99m)Tc-MIBI G-MPI and coronary artery angiography as the criterion diagnostic standard within 1 month. The sensitivity, specificity, and accuracy of ATP stress (99m)Tc-MIBI G-MPI in the assessment of in-stent restenosis were calculated. In addition, Fisher's exact probability methods were used to compare differences between experimental groups. Among 66 patients with a total of 99 implanted coronary arterial branches, 39 patients (59%) with 45 coronary arteries (45%) presented in-stent restenosis. The diagnostic sensitivity, specificity, accuracy, positive predictive and negative predictive value of ATP stress (99m)Tc-MIBI G-MPI for assessing stent restenosis in all patients were 85, 89, 86, 92 and 80%, respectively. Similarly, these values in patients with myocardial infarction were 79, 88, 83, 88 and 78%, respectively, while in patients without myocardial infarction the values were 90, 91, 90, 95 and 83%, respectively. Therefore, the diagnostic efficacy of ATP stress (99m)Tc-MIBI G-MPI in patients without myocardial infarction was higher compared with those with myocardial infarction; however, no significant difference was observed between the two groups. Furthermore, the sensitivity, specificity and

  14. Spontaneous coronary artery dissection causing acute coronary syndrome in a young patient without risk factors

    Directory of Open Access Journals (Sweden)

    Parag Chevli

    2014-09-01

    Full Text Available Spontaneous coronary artery dissection (SCAD is a rare cause of acute myocardial infarction that is more common in younger patients (under age 50 and in women. Although the etiology is not known, some predisposing conditions to SCAD are well known and include Marfan syndrome, pregnancy and peripartum state, drug abuse, and some anatomical abnormalities of the coronary arteries such as aneurysms and severe kinking. We describe a case of SCAD in a young woman who presented with sudden onset of chest pain and was admitted for the treatment of acute coronary syndrome. The coronary angiography showed dissection of the left anterior descending artery. The patient underwent successful percutaneous transluminal coronary angioplasty and stent placement.

  15. Late stent malapposition and marked positive vessel remodeling after sirolimus-eluting coronary stent implantation

    Institute of Scientific and Technical Information of China (English)

    ZHANG Feng; QIAN Ju-ying; GE Jun-bo

    2006-01-01

    @@ It has been reported that positive remodeling, regression of neointimal hyperplasia, and late malapposition are associated with brachytherapy, one of the approaches to prevent first-time and recurrent in-stent restenosis.1,2 Recently, some drug-eluting stents have been demonstrated to dramatically reduce restenosis rates.3,4 Despite these promising results, these drug-eluting stents may have the same potential risks as brachytherapy, with some similarities between the 2 technologies in anti- proliferative effects on vascular smooth muscle cells and endothelial cells. We reported a case of late stent malapposition and marked positive vessel remodeling after sirolimus-eluting coronary stent implantation.

  16. Ectopic Origin of Coronary Arteries Diagnozed by Coronary Angiography

    Science.gov (United States)

    Krasniqi, Xhevdet; Gorani, Daut; Sejdiu, Basri; Citaku, Hajdin

    2016-01-01

    Introduction: Anomalous origin of coronary arteries from opposite sinus of Valsalva is rare finding. The incidence of anomalous origination of the left coronary artery from right sinus is 0.15% and the right coronary artery from the left sinus is 0.92%. The ectopic origin of left coronary artery or right coronary artery from opposite sinus depending on pathways and considering atherosclerotic changes are manifested with different clinical significance. Case report: We report two cases, the first case the coronary angiography showed the left coronary artery arising from the right coronary sinus, presenting with proximally and distally stenosed left anterior descending artery (LAD), associated with medial and distal stenosed right coronary artery (RCA). The second case the coronary angiography revealed the right coronary artery arising from the left coronary sinus, associated with tortuous medial and distal segments of left anterior descending artery (LAD), without atherosclerotic changes. The first case successfully underwent treatment procedures based on guidelines for revascularization. Conclusion: The coronary angiography of patients with coronary ischemia determines atherosclerotic disease with possibility of the presence of coronary artery anomalies that in cases with ectopic origin from opposite sinus continues to exist as a challenge during treatment in interventional cardiology. PMID:27482140

  17. Carotid artery stent continued expansion days after deployment, without post stent deployment angioplasty

    Directory of Open Access Journals (Sweden)

    Umair Qazi

    2015-10-01

    Full Text Available This is a carotid artery stent (CAS case report, which avoids post-stent deployment angioplasty (Post-SDA, with duplex confirmed continued stent expansion at 1, 3 and 30-day post deployment. This report confirms that self-expanding nitinol stents in the carotid artery may not require Post-SDA. We believe CAS can be performed without Post-SDA, which helps reduce the occurrence of intraoperative hemodynamic depression.

  18. Drug-eluting stents in the management of peripheral arterial disease

    Directory of Open Access Journals (Sweden)

    Marc Bosiers

    2008-06-01

    Full Text Available Marc Bosiers1, Catherine Cagiannos1, Koen Deloose1, Jürgen Verbist2, Patrick Peeters21Department of Vascular Surgery, AZ St-Blasius, Dendermonde, Belgium; 2Department of Cardiovascular and Thoracic Surgery, Imelda Hospital, Bonheiden, BelgiumAbstract: Since major meta-analyses of randomized controlled trials in interventional cardiology showed the potential of drug-eluting stents in decreasing restenosis and reintervention rates after coronary artery stenting, one of the next steps in the treatment of arterial occlusive disease is the transfer of the active coating technology towards peripheral arterial interventions. In this manuscript, we aim to provide a literature overview on available peripheral (lower limb, renal, and supra-aortic drug-eluting stent applications, debate the cost implications, and give recommendations for future treatment strategies.Keywords: critical limb ischemia, drug-eluting stent, below the knee, infrapopliteal, crural, limb salvage

  19. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rose Mary Ferreira Lisboa da, E-mail: roselisboa@cardiol.br [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Silva, Carlos Augusto Bueno [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Greco, Otaviano José [Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Moreira, Maria da Consolação Vieira [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil)

    2014-08-15

    The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  20. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Directory of Open Access Journals (Sweden)

    Rose Mary Ferreira Lisboa da Silva

    2014-08-01

    Full Text Available Background: The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. Objective: To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. Methods: This study assessed 61 patients (mean age, 64.0 years; 35 men with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform, measuring the low-frequency (LF and high-frequency (HF components, and the LF/HF ratio before and during the procedure. Results: Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively, with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00. The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Conclusions: Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  1. [Changes of content of regulatory lymphocytes and concentration of soluble interleukine-2 receptor in blood of patients with ischemic heart disease after coronary artery angioplasty with implantation of stents with rapamycin covering].

    Science.gov (United States)

    Potekhina, A V; Sokolov, V O; Pylaeva, E A; Provatorov, S I; Masenko, V P; Bosykh, E G; Noeva, E A; Krasnikova, T L; Aref'eva, T I

    2011-01-01

    We studied dynamics of content of subpopulation of lymphocytes including regulatory and effector T-lymphocytes as well as concentration of soluble form of interleukine-2 receptor (sCD25) in peripheral blood of patients after coronary stenting (CS) with implantation of stents with rapamycin covering (SRC). We included into the study 62 patients with stable effort II-III functional class angina. Coronary angiography (CA) was carried out in all, CS with implantation of 1 - 2 SRC - in 42 patients. Blood samples were taken before CA/CS, in 24, 48 hours, 7 days, 1 and 3 months after intervention. Content of T-, helper and cytotoxic T-cells, -, NK-, NKT-cells, activated effector T-lymphocytes (CD4+CD251owCD127high) and regulatory T-lymphocytes (CD4+CD25highCD1271ow) were measured by direct immunofluorescence and flow cytometry. CD4+ lymphocytes were isolated from mononuclear cell fraction of donor blood by magnetic separation. Content of regulatory T-lymphocytes in culture were determined by expression of a specific marker FOXP3+. Concentration of sCD25 was measured by chemiluminescent method. It was shown that content of main subpopulations of lymphocytes in blood changed after CS or CF. Blood content of regulatory T-lymphocytes and sCD25 significantly increased after 7 days and 1 month after CS but not after CA. Plasma sCD25 concentration correlated with content of regulatory T-lymphocytes in 1 month after SRC implantation. During cultivation of CD4+ lymphocytes in the presence of rapamycin we noted antiproliferative effect relative to FOXP3-cells and accumulation of regulatory +-lymphocytes. Thus implantation of SRC in coronary arteries leads to increase of number of circulating regulatory T-lymphocytes and blood concentration of sCD25. Changes of these parameters after CS can reflect peculiarities of local and systemic reaction arising in response to introduction of stent with drug covering and be significant for assessment of prognosis of the disease.

  2. Direct coronary stenting by transradial approach: rationale and technical issues.

    Science.gov (United States)

    Burzotta, Francesco; Hamon, Martial; Trani, Carlo; Kiemeneij, Ferdinand

    2004-10-01

    Direct stent implantation using radial approach represents to date the less invasive, less traumatic strategy to perform a percutaneous coronary intervention, rendering its adoption an attraction for many interventional cardiologists. A growing series of reports suggests the feasibility of transradial direct stenting in a variety of clinical situations. Here we discuss the main advantages of the adoption of this technique. Moreover, a detailed analysis of the technical issues specifically related with each phase of transradial direct stenting procedures is reported.

  3. Optimal duration of dual antiplatelet therapy following treatment with the endeavor zotarolimus-eluting stent in real-world Japanese patients with coronary artery disease (OPERA): study design and rationale.

    Science.gov (United States)

    Nakamura, Masato; Nanto, Shinsuke; Hirayama, Atsushi; Takayama, Tadateru; Nishikawa, Masakatsu; Kimura, Kazuo; Morita, Satoshi; Aizawa, Tadanori; Asano, Ryuta; Matsumaru, Yuji; Hamada, Chikuma; Isshiki, Takaaki

    2014-09-01

    In patients with coronary artery disease (CAD), there is an increasing therapeutic need among interventional cardiologists to conduct dual antiplatelet therapy (DAPT) whose duration is shorter than current guideline-recommended 6-12 months after the implantation of drug-eluting stents. However, no clinical grounds sufficient to rationalize the need are available. To define the optimal duration of DAPT and to examine the safety and efficacy of the Endeavor zotarolimus-eluting stent (E-ZES) in real-world Japanese patients with CAD. The present prospective, nonrandomized, multicenter, controlled study is uniquely designed to examine the analysis set to be formulated after integrating two different databases consisting of the following two study arms: the 3-month DAPT arm, in which 1,210 patients were consecutively enrolled at 106 medical institutions; and the 12-month DAPT arm, in which 1,210 patients will be consecutively extracted from the Endeavor Japan post-marketing surveillance at 60 medical institutions. The primary endpoint is "net adverse cardiac and cerebrovascular events-death, myocardial infarction, cerebrovascular accident, and major bleeding)" at 12 months after implantation. The secondary endpoints are as follows: major adverse cardiac events at 1, 3, 6, 9, and 12 months after implantation; target vessel revascularization and target lesion revascularization at 9 and 12 months after implantation; and stent thrombosis, DAPT compliance, and bleeding events at 12 months after implantation. Noninferiority in the E-ZES's profiles between the study arms will be investigated. The present study will provide insight into the optimal duration of DAPT after the E-ZES implantation in individual, real-world patients with CAD. © 2013 Wiley Periodicals, Inc.

  4. Computational Analysis on Stent Geometries in Carotid Artery: A Review

    Science.gov (United States)

    Paisal, Muhammad Sufyan Amir; Taib, Ishkrizat; Ismail, Al Emran

    2017-01-01

    This paper reviews the work done by previous researchers in order to gather the information for the current study which about the computational analysis on stent geometry in carotid artery. The implantation of stent in carotid artery has become popular treatment for arterial diseases of hypertension such as stenosis, thrombosis, atherosclerosis and embolization, in reducing the rate of mortality and morbidity. For the stenting of an artery, the previous researchers did many type of mathematical models in which, the physiological variables of artery is analogized to electrical variables. Thus, the computational fluid dynamics (CFD) of artery could be done, which this method is also did by previous researchers. It lead to the current study in finding the hemodynamic characteristics due to artery stenting such as wall shear stress (WSS) and wall shear stress gradient (WSSG). Another objective of this study is to evaluate the nowadays stent configuration for full optimization in reducing the arterial side effect such as restenosis rate after a few weeks of stenting. The evaluation of stent is based on the decrease of strut-strut intersection, decrease of strut width and increase of the strut-strut spacing. The existing configuration of stents are actually good enough in widening the narrowed arterial wall but the disease such as thrombosis still occurs in early and late stage after the stent implantation. Thus, the outcome of this study is the prediction for the reduction of restenosis rate and the WSS distribution is predicted to be able in classifying which stent configuration is the best.

  5. Coronary bifurcation lesions treated with simple or complex stenting

    DEFF Research Database (Denmark)

    Behan, Miles W; Holm, Niels R; de Belder, Adam J;

    2016-01-01

    AIMS: Randomized trials of coronary bifurcation stenting have shown better outcomes from a simple (provisional) strategy rather than a complex (planned two-stent) strategy in terms of short-term efficacy and safety. Here, we report the 5-year all-cause mortality based on pooled patient-level data...

  6. Lesion load in unprotected carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Papanagiotou, P.; Roth, C.; Karp, K.; Krick, C.; Schieber, H.; Mueller, M.; Reith, W. [University of the Saarland, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Fassbender, K.; Haass, A. [University of the Saarland, Division of Neurology, Homburg (Germany)

    2009-05-15

    The purpose of the study was to determine the incidence of new ischemic lesions found on diffusion-weighted MR imaging (DWI) in nonselected patients after unprotected carotid artery stent placement. We retrospectively reviewed a nonrandomized cohort of 197 patients presenting with carotid occlusive disease who underwent unprotected carotid artery stent placement between 2003 and 2006. Mean degree of stenosis was 86.94% {+-} 9.72. In all patients, DWI was obtained before and 24 h after stent placement. New lesions were evaluated according to size and location. In 59 of 197 patients (29.9%), new ischemic lesions were found on DWI in the vessel dependent area. In 23 of 197 patients (11.7%), new ischemic lesions were found in the vessel independent area. Combined stroke/death rate was 3.63%. In our series of unprotected carotid angioplasty with stent, we found new DWI lesions in 34% of the patients. Further studies should now show in how far protection devices can reduce these lesions. (orig.)

  7. Histopathological heterogeneity of in-stent restenosis in four coronary endarterectomy specimens.

    Science.gov (United States)

    Takashima, Akira; Shimabukuro, Michio; Tabata, Minoru; Fukuda, Daiju; Uematsu, Etsuko; Ishibashi-Ueda, Hatsue; Takanashi, Shuichiro; Sata, Masataka

    2015-01-01

    Here, we histopathologically compare four patients undergoing coronary artery bypass with coronary endarterectomy and onlay patch grafting for in-stent restenosis (ISR) after the implantation of a bare-metal stent (BMS), sirolimus-eluting stent (SES), or paclitaxel-eluting stent (PES) in an everolimus-eluting stent (EES). Heterogeneity of ISR was noted histopathologically. In ISR for BMS, restenosis is likely caused by so-called neoatherosclerosis that occurred which altered the healing process of BMS implantation. Two ISR cases for SES showed a histopathological heterogeneity: one showed nodular calcified thrombus around stent strut protruding into the lumen, and the other showed concentric neointima composed of CD68-positive foam cell proliferation. In the ISR lesion for PES in EES, infiltrations with foam cells macrophages, particularly numerous eosinophilic cell infiltrations, suggest a peristent strut hypersensitivity reaction. We found a remarkable histopathological heterogeneity of ISR. The study using coronary endarterectomy specimens can give us pivotal information about the histopathological heterogeneity of ISR. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Economic outcomes of percutaneous coronary intervention with drug-eluting stents versus bypass surgery for patients with left main or three-vessel coronary artery disease: One-year results from the SYNTAX trial

    NARCIS (Netherlands)

    D.J. Cohen (David J.); T.A. Lavelle (Tara); B.A. van Hout (Ben); H. Li (Haiying); Y. Lei (Yang); J.L. Robertus; D. Pinto (Duane); E.A. Magnuson (Elizabeth); T.F. McGarry (Thomas); S.K. Lucas (Scott); R.I. Horwitz (Ralph); C.A. Henry (Carl); P.W.J.C. Serruys (Patrick); F.W. Mohr (Friedrich); A.P. Kappetein (Arie Pieter)

    2012-01-01

    textabstractObjectives: To evaluate the cost-effectiveness of alternative approaches to revascularization for patients with three-vessel or left main coronary artery disease (CAD). Background: Previous studies have demonstrated that, despite higher initial costs, long-term costs with bypass surgery

  9. Carotid artery stenting will replace carotid endarterectomy.

    Science.gov (United States)

    McCormick, Daniel J; Vlad, Tudor; Fasseas, Panayotis

    2007-09-01

    Stroke is the third leading cause of death in the United States. Carotid artery stenosis represents one of the most common etiologies of stroke. The current treatment modalities available for the treatment of carotid artery stenosis are carotid endarterectomy (CEA) and carotid artery stenting (CAS). Several clinical trials comparing CEA with medical management showed superiority of the surgical arm; however, the applicability of these results to the general population is limited by the fact that the patients and surgeons enrolled in these trials were carefully selected, and the optimal medical therapy used does not meet the current treatment standards. Carotid artery stenting has emerged as a treatment alternative to CEA, as shown in randomized trials comparing the 2 treatment modalities. Recent data from large-volume CAS registries indicate that percutaneous treatment of carotid artery stenosis compares favorably to CEA. Furthermore, the CAS trial designs make these results more applicable to the community standards. These data suggest that CAS will become the treatment of choice in patients with carotid artery stenosis.

  10. A Novel High Nitrogen Nickel-free Coronary Stents System:Evaluation in a Porcine Model

    Institute of Scientific and Technical Information of China (English)

    ZHANG Bin; CHEN Ming; ZHENG Bo; WANG Xin Gang; WANG Xi Ting; FAN Yuan Yuan; HUO Yong

    2014-01-01

    Objective To study the safety of the novel high nitrogen nickel-free austenitic stainless steel bare metal stents (BMS) in a recognized porcine coronary model and to select a better grid structure of it. Methods Three types of stents were randomly implanted in different coronary arteries of the same pig: 316L stainless steel BMS (316L-BMS) (n=12), novel high nitrogen nickel-free stents Grid A (NF-A-BMS) (n=12) and novel high nitrogen nickel-free stents Grid B (NF-B-BMS) (n=12). In total, eighteen animals underwent successful random placement of 36 oversized stents in the coronary arteries. Coronary angiography was performed after 36 d of stents implantation. Nine animals were respectively sacrificed after 14 d and 36 d for histomorphologic analysis. Results Quantitative coronary angiography (QCA) showed similar luminal loss (LL) in the three groups:(0.21±0.17) mm for 316L-BMS, (0.16±0.12) mm for NF-A-BMS, (0.24±0.15) mm for NF-B-BMS (P>0.05). Histomorphomeric analysis after 15 d and 36 d revealed that there was also no significant difference among the three groups in neointimal area (NA) with similar injury scores respectively. High magnification histomorphologic examination showed similar inflammation scores in the three groups, but NF-A-BMS group had poorer endothelialization scores compared with NF-B-BMS group, 2.00±0.63 vs. 2.83±0.41 (P=0.015) at 15 d, which also could be proved by the scanning electron microscope. However, the difference could not been observed at 36 d. Conclusion The novel NF-BMS showed similar safety as 316L-BMS during the short-term study. NF-B-BMS had better endothelialization than NF-A-BMS and this may owe to the specific strut units.

  11. Mathematical model of carotid artery for stent placement

    Science.gov (United States)

    Rahman, Tengku Husna Tengku Abdul; Din, Ummul Khair Salma; Ahmad, Rokiah @ Rozita

    2016-11-01

    The carotid artery stenting is one of the methods used to reduce the effect of artherosclerosis which caused by the thickening of the artery wall. In most of the studies, the measure of wall elasticity, shear stress and the blood pressure through the blood flow were considered. The aim of this study is to determine the position to place the stent inside the carotid artery. A mathematical model is reconstructed to determine the suitable location of the stent in the carotid artery. Throughout the study, differences in fluid flow between a normal carotid artery wall and stenosed carotid artery wall are investigated. Since the existence of the stenosis provides a resistance in the flow, it is important to identify the right position to place the stent. The stent will be placed in the position where stenosis exists to ease the blood to flow normally. Later after the stent placement, the blood flow normally through the blood vessel.

  12. Multiparity and Spontaneous Coronary Artery Dissection in the Postpartum Period

    Directory of Open Access Journals (Sweden)

    Müntecep Aşker

    2012-01-01

    Full Text Available Spontaneous coronary artery dissection (SCAD is a deadly cause of myocardial infarction (MI that mainly affects otherwise healthy, young females. Forty percent of patients die suddenly or within a few hours of symptom onset. We examine the case of a young female who presented with chest pain. She developed ST elevations in anterolateral leads mimicking ST elevation MI. Cardiac catheterization was done and showed a middle left anterior descending (LAD dissection. The patient underwent primary percutaneous transluminal coronary angioplasty with coronary stent placed in the LAD.

  13. Reperfusion hemorrhage following superior mesenteric artery stenting.

    LENUS (Irish Health Repository)

    Moore, Michael

    2012-02-03

    Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

  14. Drug-eluting stents versus bare-metal stents for acute coronary syndrome

    DEFF Research Database (Denmark)

    Feinberg, Joshua; Nielsen, Emil Eik; Greenhalgh, Janette

    2017-01-01

    not included all relevant randomised clinical trials. OBJECTIVES: To assess the benefits and harms of drug-eluting stents versus bare-metal stents in people with acute coronary syndrome. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS, SCI-EXPANDED...

  15. Drug-eluting stents in renal artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M. [Marienhospital Stuttgart, Department of Radiology, Stuttgart (Germany); Pattynama, P.M.T. [Erasmus MC-University Medical Center Rotterdam, Rotterdam (Netherlands); Talen, A. [genae associates nv, Antwerp (Belgium); Sapoval, M. [Hopital Europeen Georges Pompidou, Service de Radiologie Cardio-Vasculaire, Paris (France); Inserm U 780 epidemiologie Cardio Vasculaire, Paris (France)

    2008-04-15

    Because of higher acute and long-term success rates compared with balloon angioplasty alone, percutaneous stent implantation has become an accepted therapy for the treatment of atherosclerotic renal artery stenosis. Restenosis rates after successful renal stent placement vary from 6 up to 40%, depending on the definition of restenosis, the diameter of the treated vessel segment and comorbidities. The safety and efficacy of drug-eluting stents for the treatment of renal-artery stenosis is poorly defined. The recently published GREAT study is the only prospective study, comparing bare-metal and sirolimus-coated low profile stent systems in renal artery stenosis, showing a relative risk reduction of angiographic binary in-stent restenosis by 50%. This is an opinion paper on indications, current treatment options and restenosis rates following renal artery stenting and the potential use of drug-eluting stents for this indication. (orig.)

  16. Virtual bench testing to study coronary bifurcation stenting.

    Science.gov (United States)

    Migliavacca, Francesco; Chiastra, Claudio; Chatzizisis, Yiannis S; Dubini, Gabriele

    2015-01-01

    Virtual bench testing is a numerical methodology which has been applied to the study of coronary interventions. It exploits the amazing growth of computer performance for scientific calculation and makes it possible to simulate very different and complex multiphysics environments and processes, including coronary bifurcation stenting. The quality of prediction from any computer model is very sensitive to the quality of the input data and assumptions. This also holds true in stent virtual bench testing. This paper reviews the state of the art in the field of bifurcation stenting modelling and identifies the current advantages and limitations of this methodology.

  17. Spontaneous coronary artery dissection as a cause of myocardial infarction

    Institute of Scientific and Technical Information of China (English)

    Aytekin; Aksakal; U?ur; Arslan; Mehmet; Yaman; Mehmet; Urumda?; Ahmet; Hakan; Ate?

    2014-01-01

    Spontaneous coronary artery dissection(SCAD) is a rare disease that is usually seen in young women in left descending coronary artery and result in events like sudden cardiac death and acute myocardial infarction. A 70-year-old man was admitted to the emergency department with chest pain which started 1 h ago during a relative’s funeral. The initial electrocardiography demonstrated 2 mm ST-segment depression in leads V1-V3 and the patient underwent emergent coronary angiography. SCAD simultaneously in two different coronary arteries [left anterior descending(LAD) artery and left circumflex(LCx)] artery was detected and SCAD in LCx artery was causing total occlusion which resulted in acute myocardial infarction. Successful stenting was performed thereafter for both lesions. In addition to the existence of SCAD simultaneously in two different coronary arteries, the presence of muscular bridge and SCAD together at the same site of the LAD artery was another interesting point which made us report this case.

  18. Paraffin processing of stented arteries using a postfixation dissolution of metallic and polymeric stents.

    Science.gov (United States)

    Fishbein, Ilia; Welch, Tre; Guerrero, David T; Alferiev, Ivan S; Adamo, Richard F; Chorny, Michael; Gupte, Rohit K; Tang, Yanqing; Levy, Robert J

    Studying the morphology of the arterial response to endovascular stent implantation requires embedding the explanted stented artery in rigid materials such as poly(methyl methacrylate) to enable sectioning through both the in situ stent and the arterial wall, thus maintaining the proper anatomic relationships. This is a laborious, time-consuming process. Moreover, the technical quality of stained plastic sections is typically suboptimal and, in some cases, precludes immunohistochemical analysis. Here we describe a novel technique for dissolution of metallic and plastic stents that is compatible with subsequent embedding of "destented" arteries in paraffin, fine sectioning, major staining protocols, and immunohistochemistry.

  19. Diagnostic value of magnetocardiography in patients with coronary heart disease and in-stent restenosis

    Institute of Scientific and Technical Information of China (English)

    QUAN Wei-wei; LU Guo-ping; QI Wen-hang; LI Ying-mei; SHEN Yue; YUAN Rong

    2008-01-01

    Background In-stent restenosis (ISR) has become one of the most challenging problems in patients with coronary heart disease. At present, using non-invasive methods to assess ISR is a hol topic. In this investigation we attempted to explore the potential of magnetocardiography (MCG) in diagnosis of in-stent restenosis.Methods MCG was analyzed in 52 patients with coronary artery disease for three times: before stenting, one month and 7 months after successful intracoronary stenting.Results The average classification of total maps (ACTM) and the ratio of abnormal maps (RAM) were Iower in 1 month after intracoronary stenting compared with that obtained before stent planting (2.91 vs 2.52, 65.74% vs 42.80%, P<0.01),while complex ventricular excitation Index (CVEI) increased from -42.63 to -20.05 (P<0.01). In ISR subgroup (n=16),RAM decreased in 1 month after intracoronary stenting compared to it before stenting (68.99% vs 45.26%, P<0.05).ACTM increased in 7 months compared to that obtained in 1 month after stenting (3.15 vs 2.51, P<0.05). According to the ROC curve, ACTM showed its unique diagnostic value in restenosis patients. The sensitivity and specificity of ACTM were 80.0%, 69.40%, respectively. Its positive predictive value and negative predictive value were 54.6% and 88.5%,respectively.Conclusions After successful intracoronary stenting, most parameters of MCG were improved. ACTM was of prognostic value in diagnosing ISR.

  20. Artery Soft-Tissue Modelling for Stent Implant Training System

    Directory of Open Access Journals (Sweden)

    Giovanni Aloisio

    2004-08-01

    Full Text Available Virtual reality technology can be utilised to provide new systematic training methods for surgical procedures. Our aim is to build a simulator that allows medical students to practice the coronary stent implant procedure and avoids exposing patients to risks. The designed simulation system consists of a virtual environment and a haptic interface, in order to provide both the visualization of the coronary arteries and the tactile and force feedback generated during the interactions of the surgical instruments in the virtual environment. Since the arteries are soft tissues, their shape may change during an operation; for this reason physical modelling of the organs is necessary to render their behaviour under the influence of surgeon's instruments. The idea is to define a model that computes the displacement of the tissue versus time; from the displacement it is possible to calculate the response of the tissue to the surgical tool external stimuli. Information about tools displacements and tissue responses are also used to graphically model the artery wall and virtual surgical instrument deformations generated as a consequence of their coming into contact. In order to obtain a realistic simulation, the Finite Element Method has been used to model the soft tissues of the artery, using linear elasticity to reduce computational time and speed up interaction rates.

  1. Microguidewire Looping to Traverse Stented Parent Arteries of Intracranial Aneurysms

    Science.gov (United States)

    Cho, Young Dae; Rhim, Jong Kook; Yoo, Dong Hyun; Kang, Hyun-Seung; Kim, Jeong Eun; Han, Moon Hee

    2017-01-01

    Objective Stents are widely used in coil embolization of intracranial aneurysms, but on occasion, a microcatheter must traverse a stented segment of artery (so-called trans-cell technique) to select an aneurysm, or double stenting may necessary. In such situations, microguidewire passage and microcatheter delivery through a tortuous stented parent artery may pose a technical challenge. Described herein is a microguidewire looping technique to facilitate endovascular navigation in these circumstances. Methods To apply this technique, the microguidewire tip is looped before entering the stented parent artery and then advanced distally past the stented segment, with the loop intact. Rounding of the tip prevents interference from stent struts during passage. A microcatheter is subsequently passed into the stented artery for positioning near the neck of aneurysm, with microguidewire assistance. The aneurysm is then selected, steering the microcatheter tip (via inner microguidewire) into the dome. Results This technique proved successful during coil embolization of nine saccular intracranial aneurysms (internal carotid artery [ICA], 6; middle cerebral artery, 2; basilar tip, 1), performing eight trans-cell deliveries and one additional stenting. Selective endovascular embolization was enabled in all patients, resulting in excellent clinical and radiologic outcomes, with no morbidity or mortality directly attributable to microguidewire looping. Conclusion Microguidewire looping is a reasonable alternative if passage through a stented artery is not feasible by traditional means, especially at paraclinoid ICA sites. PMID:28264249

  2. Comparison of short- and mid-term outcomes between CYPHER and TAXUS stents in patients with complex lesions of the coronary arteries

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background Drug-eluting stent (DES) could obviously reduce in-stent restenosis, which has been proved by international multi-center clinical trials. However, the types of the lesions for stenting were highly selected in these trials. Up to now, there has been no large scale study on the effect of DES in treating complex lesions in real world. Although REALITY trial was just reported during American College of Cardiology Congress 2005, the entry criteria for lesions were limited to one or two de novo lesions. This study was conducted to compare the short- and mid-term clinical outcomes between sirolimus-eluting stent (CYPHER stent) and paclitaxel-eluting stent (TAXUS stent) in patients with complex lesion. Methods This is a retrospective study. From April 2002 to June 2004, a total of 1061 patients were treated with DES in Fu Wai Hospital, of which, 611 patients (642 lesions with 698 CYPHER stents) were in CYPHER group,and 450 patients (534 lesions with 600 TAXUS stents) were in TAXUS group. There was no significant difference in clinical data and lesion types between CYPHER group and TAXUS group. Results Success rates of stent implantation were 99.2% and 98.8% in CYPHER and TAXUS stent groups respectively. The major adverse cardiac events (MACE) during in-hospital and 6-8-month follow-up were 0.7% and 2.3% in CYPHER stent group versus 1.3% and 3.2% in TAXUS stent group. There was no significant difference in MACE rate between these two groups. Restenosis rate was a little higher in TAXUS stent group than that in CYPHER stent group (14.0% vs 7.3%), but there was no significant difference. The incidence of acute occlusion of side branch after implanting DES in main vessel was 6.9% in CYPHER group and 11.9% in TAXUS group(P<0.05).Conclusions CYPHER and TAXUS DES were safe and effective in patients with complex lesion. Clinical outcomes of CYPHER stent were better than TAXUS stent in bifurcation lesions. There was an increasing tendency in restenosis rate and late

  3. Physiologic assessment of coronary artery fistula

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, N.C.; Beauvais, J. (Creighton Univ., Omaha, NE (USA))

    1991-01-01

    Coronary artery fistula is an uncommon clinical entity. The most common coronary artery fistula is from the right coronary artery to the right side of the heart, and it is less frequent to the pulmonary artery. The effect of a coronary artery fistula may be physiologically significant because of the steal phenomenon resulting in coronary ischemia. Based on published reports, it is recommended that patients with congenital coronary artery fistulas be considered candidates for elective surgical correction to prevent complications including development of congestive heart failure, angina, subacute bacterial endocarditis, myocardial infarction, and coronary aneurysm formation with rupture or embolization. A patient is presented in whom treadmill-exercise thallium imaging was effective in determining the degree of coronary steal from a coronary artery fistula, leading to successful corrective surgery.

  4. Recurrent Syncope Attributed to Left Main Coronary Artery Severe Stenosis

    Directory of Open Access Journals (Sweden)

    Min Li

    2015-01-01

    Full Text Available Patients with acute coronary syndrome (ACS rarely manifest as recurrent syncope due to malignant ventricular arrhythmia. We report a case of a 56-year-old Chinese male with complaints of paroxysmal chest burning sensation and distress for 2 weeks as well as loss of consciousness for 3 days. The electrocardiogram (ECG revealed paroxysmal multimorphologic ventricular tachycardia during attack and normal heart rhythm during intervals. Coronary angiograph showed 90% stenosis in left main coronary artery and 80% stenosis in anterior descending artery. Two stents sized 4.0*18 mm and 2.75*18 mm were placed at left main coronary artery and anterior descending artery, respectively, during percutaneous coronary intervention (PCI. The patient was discharged and never had ventricular arrhythmia again during a 3-month follow-up since the PCI. This indicated that ventricular tachycardia was correlated with persistent severe myocardial ischemia. Coronary vasospasm was highly suspected to be the reason of the sudden attack and acute exacerbation. PCI is recommended in patients with both severe coronary artery stenosis and ventricular arrhythmia. Removing myocardial ischemia may stop or relieve ventricular arrhythmia and prevent cardiac arrest.

  5. FORMATION OF SIX SIGMA INFRASTRUCTURE FOR THE CORONARY STENTING PROCESS

    Directory of Open Access Journals (Sweden)

    Mehmet Tolga Taner

    2013-10-01

    Full Text Available The purpose of this study is to show how a tertiary care center in Turkey operating mainly in cardiology initiated Six Sigma principles to reduce the number of complications occuring during coronary stent insertion process. A Six Sigma’s Define-Measure-Analyze-Improve-Control (DMAIC model for coronary stent insertion is suggested. Data were collected for 24-months. Twenty-two Critical-to-Quality (CTQ factors were identified for successful coronary stent insertion. The most frequent causes of complications in the process were found to be patients with previous bypass surgery or PCI, inexperience of staff members, highly damaged vessel structure, thin and/or long vessel diameter, inappropriate selection of stent type, inappropriate selection of balloon type and poor image quality.

  6. Safety, efficacy and costs associated with direct coronary stenting compared with stenting after predilatation

    Science.gov (United States)

    IJsselmuiden, A.; Serruys, P.W.; Tangelder, G.J.; Slagboom, T.; van der Wieken, R.; Kiemeneij, F.; Laarman, G.J.

    2004-01-01

    Objectives Comparison of the in-hospital success rates, procedural costs and short-term clinical outcomes of direct stenting versus stenting after balloon predilatation. Methods Altogether, 400 patients with angina pectoris and/or myocardial ischaemia due to coronary stenoses in a single native vessel were randomised to either direct stenting or stenting after predilatation. Baseline characteristics were evenly distributed between the two groups. Results Procedural success rates were similar (96.0% direct stenting group vs. 94.5% predilatation) as well as final successful stent implantation (98.3 vs. 97.8%), while the primary success rate of direct stenting alone was 88.3%, p=0.01. In multivariate analysis, angiographic lesion calcification was an independent predictor of unsuccessful direct stenting (odds ratio 7.1, 95% confidence interval 2.8-18.2, p0.15 μg/l, used as a measure of distal embolisation, were similar in both groups (17.8 vs. 17.1%). Rates of major adverse cardiac events at 30 days were 4.5% in the direct stenting group versus 5.5% in the predilated group (ns). Direct stenting was associated with savings in fluoroscopy time, and angiographic contrast agent use, and a reduction in utilisation of angioplasty balloons (0.4 vs. 1.17 balloons per patient, p<0.001). Mean per patient procedural costs associated with direct stenting versus predilatation were €2545±914 versus €2763±842 (p=0.01), despite the implantation of more stents in the directly stented group. Conclusion Compared with a strategy of stenting preceded by balloon predilatation, direct stenting was equally safe and effective, with similar in-hospital and 30-day clinical outcomes, and modest procedural cost-savings. A calcified lesion predicted unsuccessful direct stenting. PMID:25696356

  7. Bioresorbable Drug-Eluting Magnesium-Alloy Scaffold for Treatment of Coronary Artery Disease

    OpenAIRE

    Campos, Carlos M.; Takashi Muramatsu; Javaid Iqbal; Ya-Jun Zhang; Yoshinobu Onuma; Garcia-Garcia, Hector M.; Michael Haude; Lemos, Pedro A.; Boris Warnack; Serruys, Patrick W.

    2013-01-01

    The introduction of metallic drug-eluting stents has reduced the risk of restenosis and widened the indications of percutaneous coronary intervention in treatment of coronary artery disease. However, this medical device can induce hypersensitive reaction that interferes with the endothelialization and healing process resulting in late persistent or acquired malapposition of the permanent metallic implant. Delayed endotheliaization and malapposition may lead to late and very late stent thrombo...

  8. Effects of sirolimus-eluting stent on calcified coronary lesions

    Institute of Scientific and Technical Information of China (English)

    LI Jian-jun; WU Yong-jian; YUAN Jin-qing; CHEN Jue; YOU Shi-jie; DAI Jun; XIA Ran; GAO Run-lin; XU Bo; YANG Yue-jin; CHEN Ji-lin; QIAO Shu-bing; MA Wei-hua; QIN Xue-wen; YAO Min; LIU Hai-bo

    2008-01-01

    Background Calcified coronary lesions carry the risk of suboptimal stent expansion, subsequently leading to restenosis. The effectiveness of sirolimus-eluting stents (SES) for the treatment of calcified lesion has not been fully investigated. In the present study, therefore, we evaluated the effectiveness of SES Implantation for the treatment of calcified coronary lesions.Mothods A total of 333 consecutive patients with 453 lesions were enrolled in this study. They were divided into two groups according to whether the lesion treated with SES was calcified or not; no calcification group (n=264) and calcification group (n=189). Lesions treated with SES were subjected to quantitative coronary angiography (QCA) immediately and 8 months following stenting.Results Baseline clinical, demographic or angiographic characteristics were well balanced in both groups. Angiographic follow-up at 8 months, the in-stent restenosis and in-segment restenosis rates were not significantly different between the two groups; in-stent restenosis: 3.8% vs 4.2%; P=0.081; in-segment restenosis: 8.7% vs 10.6%, P=0.503. The target lesion revascularization (TLR) was also not significantly different between the two groups; 4.9% vs 6.9%, P=0.378. In addition, the in-stent late loss was similar in both groups; (0.16±0.40) mm vs (0.17±0.33) mm, P>0.05. Meantime, overall thrombosis rates were also similar in both groups; 1.6% vs 1.6%, P>0.05.Conclusion Although calcified coronary lesion was hard to stent, successful percutaneous coronary intervention with SES stenting for calcified lesions was conferred by the similar favorable results that were seen when comparing non-calcified and calcified coronary lesions.

  9. Next generation coronary CT angiography: in vitro evaluation of 27 coronary stents

    Energy Technology Data Exchange (ETDEWEB)

    Gassenmaier, Tobias; Bley, Thorsten A. [University Hospital Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); Petri, Nils; Voelker, Wolfram [University Hospital Wuerzburg, Department of Internal Medicine I, Wuerzburg (Germany); Allmendinger, Thomas; Flohr, Thomas [Siemens Healthcare, Forchheim (Germany); Maintz, David [University of Cologne, Department of Radiology, Cologne (Germany)

    2014-11-15

    To evaluate in-stent lumen visibility of 27 modern and commonly used coronary stents (16 individual stent types, two stents at six different sizes each) utilising a third-generation dual-source CT system. Stents were implanted in a plastic tube filled with contrast. Examinations were performed parallel to the system's z-axis for all stents (i.e. 0 ) and in an orientation of 90 for stents with a diameter of 3.0 mm. Two stents were evaluated in different diameters (2.25 to 4.0 mm). Examinations were acquired with a collimation of 96 x 0.6 mm, tube voltage of 120 kVp with 340 mAs tube current. Evaluation was performed using a medium-soft (Bv40), a medium-sharp (Bv49) and a sharp (Bv59) convolution kernel optimised for vascular imaging. Mean visible stent lumen of stents with 3.0 mm diameter ranged from 53.3 % (IQR 48.9 - 56.7 %) to 73.9 % (66.7 - 76.7 %), depending on the kernel used at 0 , and was highest at an orientation of 90 with 80.0 % (75.6 - 82.8 %) using the Bv59 kernel, strength 4. Visible stent lumen declined with decreasing stent size. Use of third-generation dual-source CT enables stent lumen visibility of up to 80 % in metal stents and 100 % in bioresorbable stents. (orig.)

  10. Delayed cerebral infarction due to stent folding deformation following carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kwon Duk; Lee, Kyung Yul; Suh, Sang Hyun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    We report a case of delayed cerebral infarction due to stent longitudinal folding deformation following carotid artery stenting using a self-expandable stent with an open-cell design. The stented segment of the left common carotid artery was divided into two different lumens by this folding deformation, and the separated lumens became restricted with in-stent thrombosis. Although no established method of managing this rare complication exists, a conservative approach was taken with administration of anticoagulant and dual antiplatelet therapy. No neurological symptoms were observed during several months of clinical follow-up after discharge.

  11. In situ coronary stent paving by Pluronic F127-alginate gel blends: Formulation and erosion tests.

    Science.gov (United States)

    Dalmoro, Annalisa; Barba, Anna Angela; Grassi, Mario; Grassi, Gabriele; Lamberti, Gaetano

    2016-07-01

    In this work the development of an experimental protocol to perform the in situ gel-paving of coronary stent is presented. Biocompatible aqueous blends of Pluronic F127 and sodium alginates are used as potential drug dosage system for pharmacological in situ treatment of coronary in-stent restenosis. Pluronic F127/alginate aqueous blend has the unique characteristic to be liquid at room condition and to form gel at physiological temperature. The proposed protocol is based on the blend injection on stent wall previously implanted in a flexible silicon pipe mimicking the coronary artery. Injected blend is warmed up until human body temperature achieving a soft gel, then it is reticulated by copper bivalent ions to obtain an hard gel. To test the gel paving resistance to erosion phenomena when it is exposed to fluid flux (i.e. blood flux) a dedicated device, (the Simulated Artery Device, SAD), was built to simulate the human circulatory apparatus. The SAD is an hydraulic circuit in which a buffer solution (at pH 7.4) was fluxed by a peristaltic pump through the pipe hosting the covered stent. Erosion tests were performed monitoring, by gravimetric and spectrophotometric methods, the residual mass anchored to stent mesh after given times. The obtained results showed that the in situ gel-paving developed protocol was efficacious and reliable. The gel-paving was completely eroded in a time of the same order of magnitude of the physiological period required to restore the coronary lesion (subsequent to the atheroma removal) and of a pharmacological therapy to inhibit the in-stent-restenosis pathology. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1013-1022, 2016.

  12. Coronary Artery Bypass in Octogenarians

    Directory of Open Access Journals (Sweden)

    Chen-Yen Chien

    2012-09-01

    Full Text Available Prevalence of coronary artery disease (CAD has increased with the expansion of life span among the elderly population in the world. Hence, the issue of the coronary artery bypass in octogenarians has attracted more attention. Recent literature about the topic revealed nearly the same excellent results as those in the younger population under the newly developed operative techniques and improving concept in perioperative management and postoperative care. In this article, we review the current status of the procedure that was thought to be dangerous in the earlier era, including its risk factors, result, and benefit.

  13. Rare occurrence of simultaneous coronary artery perforation and intracoronary thrombus formation following angioplasty

    Institute of Scientific and Technical Information of China (English)

    Su-Yan Bian; Liu-Fa Duan

    2013-01-01

    Both coronary artery perforation and intracoronary thrombus formation are life-threatening complications of percutaneous coronary interventions, which rarely occur simultaneously during angioplasty. We herein report a case of stent-related, left circumflex artery perforation, and subsequently acute left main artery thrombosis after the leakage was embolized with 7 microcoils. Intracoronary thromboectomy and systemic anticoagulant therapy were carefully used with good results. This case also represents some of our uncertainties regarding the best management of the patient.

  14. Neoatherosclerosis in the stent

    Directory of Open Access Journals (Sweden)

    A. A. Komkov

    2015-01-01

    Full Text Available Achievements of interventional cardiology in the treatment of coronary artery disease are based on coronary balloon angioplasty with implanting bare metal stents and drug eluting stents. Questions of complications such as early stent thrombosis and restenosis of stent were solved in a considerable degree. However, with the lengthening of the followup period, the problem of late complications became obvious. Except endothelization and fibromuscular proliferation in stented coronary arteries the process of plaque formation has an important influence on later complications in follow-up period more than one year. This process was defined as neoatherosclerosis. This is verified by clinical manifestations of the disease, histological studies, angioscopy, intravascular ultrasound and optical-coherence tomography in stented patients. Dynamic observation of the condition in stentedcoronary arteries showed multistep proliferation with restenosis, its regression, and neoatherosclerosis development. Evidences of neoatherosclerosis formation in stented coronary arteries are considered in this review.

  15. Detailing radio frequency heating induced by coronary stents: a 7.0 Tesla magnetic resonance study.

    Science.gov (United States)

    Santoro, Davide; Winter, Lukas; Müller, Alexander; Vogt, Julia; Renz, Wolfgang; Ozerdem, Celal; Grässl, Andreas; Tkachenko, Valeriy; Schulz-Menger, Jeanette; Niendorf, Thoralf

    2012-01-01

    The sensitivity gain of ultrahigh field Magnetic Resonance (UHF-MR) holds the promise to enhance spatial and temporal resolution. Such improvements could be beneficial for cardiovascular MR. However, intracoronary stents used for treatment of coronary artery disease are currently considered to be contra-indications for UHF-MR. The antenna effect induced by a stent together with RF wavelength shortening could increase local radiofrequency (RF) power deposition at 7.0 T and bears the potential to induce local heating, which might cause tissue damage. Realizing these constraints, this work examines RF heating effects of stents using electro-magnetic field (EMF) simulations and phantoms with properties that mimic myocardium. For this purpose, RF power deposition that exceeds the clinical limits was induced by a dedicated birdcage coil. Fiber optic probes and MR thermometry were applied for temperature monitoring using agarose phantoms containing copper tubes or coronary stents. The results demonstrate an agreement between RF heating induced temperature changes derived from EMF simulations versus MR thermometry. The birdcage coil tailored for RF heating was capable of irradiating power exceeding the specific-absorption rate (SAR) limits defined by the IEC guidelines by a factor of three. This setup afforded RF induced temperature changes up to +27 K in a reference phantom. The maximum extra temperature increase, induced by a copper tube or a coronary stent was less than 3 K. The coronary stents examined showed an RF heating behavior similar to a copper tube. Our results suggest that, if IEC guidelines for local/global SAR are followed, the extra RF heating induced in myocardial tissue by stents may not be significant versus the baseline heating induced by the energy deposited by a tailored cardiac transmit RF coil at 7.0 T, and may be smaller if not insignificant than the extra RF heating observed under the circumstances used in this study.

  16. Detailing radio frequency heating induced by coronary stents: a 7.0 Tesla magnetic resonance study.

    Directory of Open Access Journals (Sweden)

    Davide Santoro

    Full Text Available The sensitivity gain of ultrahigh field Magnetic Resonance (UHF-MR holds the promise to enhance spatial and temporal resolution. Such improvements could be beneficial for cardiovascular MR. However, intracoronary stents used for treatment of coronary artery disease are currently considered to be contra-indications for UHF-MR. The antenna effect induced by a stent together with RF wavelength shortening could increase local radiofrequency (RF power deposition at 7.0 T and bears the potential to induce local heating, which might cause tissue damage. Realizing these constraints, this work examines RF heating effects of stents using electro-magnetic field (EMF simulations and phantoms with properties that mimic myocardium. For this purpose, RF power deposition that exceeds the clinical limits was induced by a dedicated birdcage coil. Fiber optic probes and MR thermometry were applied for temperature monitoring using agarose phantoms containing copper tubes or coronary stents. The results demonstrate an agreement between RF heating induced temperature changes derived from EMF simulations versus MR thermometry. The birdcage coil tailored for RF heating was capable of irradiating power exceeding the specific-absorption rate (SAR limits defined by the IEC guidelines by a factor of three. This setup afforded RF induced temperature changes up to +27 K in a reference phantom. The maximum extra temperature increase, induced by a copper tube or a coronary stent was less than 3 K. The coronary stents examined showed an RF heating behavior similar to a copper tube. Our results suggest that, if IEC guidelines for local/global SAR are followed, the extra RF heating induced in myocardial tissue by stents may not be significant versus the baseline heating induced by the energy deposited by a tailored cardiac transmit RF coil at 7.0 T, and may be smaller if not insignificant than the extra RF heating observed under the circumstances used in this study.

  17. Fabrication of hydrophobic structures on coronary stent surface based on direct three-beam laser interference lithography

    Science.gov (United States)

    Gao, Long-yue; Zhou, Wei-qi; Wang, Yuan-bo; Wang, Si-qi; Bai, Chong; Li, Shi-ming; Liu, Bin; Wang, Jun-nan; Cui, Cheng-kun; Li, Yong-liang

    2016-05-01

    To solve the problems with coronary stent implantation, coronary artery stent surface was directly modified by three-beam laser interference lithography through imitating the water-repellent surface of lotus leaf, and uniform micro-nano structures with the controllable period were fabricated. The morphological properties and contact angle (CA) of the microstructure were measured by scanning electron microscope (SEM) and CA system. The water repellency of stent was also evaluated by the contact and then separation between the water drop and the stent. The results show that the close-packed concave structure with the period of about 12 μm can be fabricated on the stent surface with special parameters (incident angle of 3°, laser energy density of 2.2 J·cm-2 and exposure time of 80 s) by using the three-beam laser at 1 064 nm, and the structure has good water repellency with CA of 120°.

  18. Endovascular rescue from arterial rupture and thrombosis during middle cerebral artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, J.Y.; Chung, Y.S. [Department of Neurosurgery, College of Medicine, Pundang CHA Hospital, 351 Yatap-ding, Pundang-gu, 463-712, Sungnam (Korea); Lee, B.H. [Department of Interventional Neuroradiology, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea); Kim, O.J. [Department of Emergency Medicine, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea)

    2003-08-01

    Intravascular stents are being used with increasing frequency in interventional neuroradiology. Iatrogenic arterial rupture is an uncommon but serious complication. We present a case of arterial rupture and subarachnoid haemorrhage during middle cerebral artery stenting, treated by emergency additional, overlapping stenting and balloon tamponade of the dissected vessel. Thrombotic occlusion of the artery was managed by intra-arterial abciximab. Normal vessel patency was re-established within 20 min and the patient recovered with no neurological deficit. (orig.)

  19. Efficacy of recombinant tissue-type plasminogen activator thrombolysis and primary coronary stenting after acute myocardial infarction

    Institute of Scientific and Technical Information of China (English)

    陈步星; 王伟民; 赵红; 胡大一; 徐成斌; 赵明中; 卢明瑜; 刘健; 吴淳

    2003-01-01

    Objective To compare the efficacy of low dose recombinant tissue-type plasminogen activator (rt-PA) thrombolysis with primary coronary stenting after acute myocardial infarction.Methods Of 261 patients with first acute myocardial infarction, 131 were given low dose rt-PA intravenous thrombolysis, and 130 primary coronary stenting.Results The age, time from onset of chest pain to hospital presentation and infarct location between these two groups were comparable. The patency rate of the infarct-related artery (IRA) in patients in the thrombolysis group was significantly lower than that of patients in the primary stenting group (P0.05).Conclusion Comparing with low dose rt-PA thrombolytic therapy after acute myocardial infarction, primary coronary stenting has a higher patency rate of the IRA, better cardiac function and shorter hospitalization time.

  20. Coronary artery spasm

    Science.gov (United States)

    ... Saunders; 2016:chap 71. Giugliano RP, Cannon CP, Braunwald E. Non-ST elevation acute coronary syndromes In: Mann DL, Zipes DP, Libby P, Bonow RO, Braunwald E, eds. Braunwald's Heart Disease: A Textbook of ...

  1. 53. Bilateral ductal stenting for nonconfluent pulmonary arteries in a newborn

    Directory of Open Access Journals (Sweden)

    K. Al Dhahri

    2016-07-01

    Full Text Available Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Limited data available for bilateral PDA stenting. Bilateral PDA stenting in nonconfluent pulmonary arteries is challenging procedure but can be considered as an option in the management of complex conditions like this. 12 days old Preterm (36 weeks gestation male baby with birth weight of 2.6 kg developed respiratory distress with severe cyanosis and desaturation upto 50%. Baby was intubated and started on Prostaglandin 0.05 mic/kg/mt. His saturation improved to 80%. Echocardiogram showed complex cyanotic heart disease, Situs ambiguous, dextrocardia, complete unbalanced AV septal defect, pulmonary atresia , nonconfluent small branch pulmonary arteries supplied by the bilateral patent ductus arteriosus (PDA from right aortic arch and all four pulmonary veins form a confluence and drain into superior vena cava(SVC through vertical vein with no obstruction. Baby was taken up for PDA stenting. descending aortogram showed right aortic arch with vertical tortuous duct to right pulmonary artery (RPA and another short duct with acute angle from left subclavian artery to left pulmonary artery (LPA . Both ducti stented with coronary stents. Vertical vein angiogram showed both lungs drain to a confluence and then to SVC via ascending vertical vein with no obstruction. After stenting lung perfusion improved and the baby was stable and maintained 80% saturation on room air. Bilateral PDA dependent pulmonary circulation with right and left pulmonary artery discontinuity is very rare. Our case is unique with Heterotaxy, TAPVC, Dextrocardia and double ducti. Eventhough bilateral ductal stenting is technically challenging it is successful through femoral artery approach.

  2. Bioresorbable drug-eluting magnesium-alloy scaffold for treatment of coronary artery disease

    NARCIS (Netherlands)

    C.A.M. Campos (Carlos); T. Muramatsu (Takashi); A. Iqbal (Anwarul); Y.-J. Zhang (Ya-Jun); Y. Onuma (Yoshinobu); H.M. Garcia-Garcia (Hector); M. Haude; P.A. Lemos Neto (Pedro); B. Warnack (Boris); P.W.J.C. Serruys (Patrick)

    2013-01-01

    textabstractThe introduction of metallic drug-eluting stents has reduced the risk of restenosis and widened the indications of percutaneous coronary intervention in treatment of coronary artery disease. However, this medical device can induce hypersensitive reaction that interferes with the endothel

  3. Aorta-LITA Bypass Grafting with Saphenous Vein in a Patient Undergoing Coronary Artery Surgery with Subclavian Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Kerim Çağlı

    2011-12-01

    Full Text Available The internal thoracic artery (ITA is the primary graft for coronary artery bypass grafting and can not be used if there is subclavian artery stenosis (SAS. Aorto-axillary, carotid-subclavian bypass and also angioplasty with stenting or other interventional treatments are acceptable procedures for SAS treatment. Aorta-ITA bypass with saphenous vein can be alternative and simple technique for SAS to save Winslow pathway for patients with peripheral artery disease.

  4. Left Coronary Artery-Pulmonary Artery Fistula in Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Orhan Veli Doğan

    2012-08-01

    Full Text Available Coroner artery fistula which is rare and congenital or acquired arise from whole coroner artery drainage all of cardiac chamber and great artery. Although coroner artery fistula is uncommon, it can cause significant mortality and morbidity rates. The article is presented which coroner artery disease and coroner-pulmonary artery fistula was accomplishment committed. Sixty three year-old male patient admitted to the hospital with chest pain. Non-ST myocardial infarction was diagnosed in the examinations. After coroner angiography, it was found coronary artery disease in addition between LAD proximal portion and main pulmonary artery fistula. Fistula repair and coronary bypass were performed successfully under cardiopulmonary bypass. Without hemodynamic problem in intensive care and service follow-up, the patient was discharged from the hospital in the seventh postoperative day. We think that surgical treatment of coronary fistulas in patients with coronary artery lesion is done at the earliest time would enable improvement in mortality and morbidity rates.

  5. Acute intracerebral haemorrhage complication after carotid artery stenting

    OpenAIRE

    Chiriac A.; Ion Georgiana; Dobrin N.; Poeata I.

    2015-01-01

    Intracranial hemorrhage following carotid artery stenting is a recognized rare complication but with potentially devastating evolution. Reports of acute cerebral hemorrhage injury following internal carotid artery (ICA) angioplasty are few, and usually were discussed in correlation with hyperperfusion syndrome. In this article we present a patient who experienced a fatal ipsilateral basal ganglia hemorrhage within 10 minutes after carotid angioplasty and stent placement

  6. The effects of post coronary stenting triple antiplatelet therapies on platelet functions

    Institute of Scientific and Technical Information of China (English)

    韩雅玲

    2006-01-01

    Objective To explore the effects of triple antiplatelet therapy on platelet aggregation and activation in patients who underwent coronary stenting. Methods 120 inhospital coronary heart disease patients with coronary stenting were randomized into two groups receiving either triple antiplatelet drugs of aspirin and clopidogrel combined with cilostazol or dual antiplatelet drugs of aspirin and clopidogrel. On the first day after stenting cilostazol

  7. Sirolimus-eluting versus bare-metal stent implantation in patients with ostial lesions

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Kelbæk, Henning; Kløvgaard, Lene;

    2010-01-01

    To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries.......To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries....

  8. Crush stenting in treating coronary bifurcate lesions: paclitaxel eluting stents versus sirolimus eluting stents

    Institute of Scientific and Technical Information of China (English)

    CHEN Shao-liang; SUN Xue-wen; HU Da-yi; Tak W. Kwan; ZHANG Jun-jie; YE Fei; CHEN Yun-dai; ZHU Zhong-sheng; LIN Song; TIAN Nai-liang; LIU Zhi-zhong; FANG Wei-yi

    2008-01-01

    Background Because no data regarding the comparison of crush stenting with pactitaxel(PES)or sirolimus eluting stents(SES)for coronary bifurcate lesions have been reported,we compared the clinical outcomes of these two types of stents.Methods Two hundred and thirty patients with 242 bifurcate lesions were enrolled in a prospective,nonrandomized trial.Primary endpoints included myocardial infarction,cardiac death and target vessel revascularization at 8 months.Results All patients were followed up clinically and 82%angiographically at 8 months.Final kissing balloon inflation was performed in 72%in the PES and 75%in the SES groups(P>0.05).Compared to the SES group,PES group had a higher late loss and incidence of restenosis(P=0.04)in the prebifurcation vessel segment.The postbifurcation vessel segment in the PES group had a greater late loss((0.7+0.6)mm vs(0.3±0.4)mm,P<0.001)and higher restenosis in the side branch(25.5%vs 15.6%,P=0.04)when compared to the SES group.There was significant difference of insegment restenosis in the entire main vessel between PES and SES groups (P=0.004).Target lesion revascularization was more frequently seen in the PES group as compared to the SES group(P=0.01).There was significant difference in the accumulative MACE between these two groups(P=0.01).The survival rate free from target lesion revascularization was significantly higher in the SES group when compared to the PES group(P<0.001).Conclusion SES is superior to PES in reducing restenosis and target lesion revascularization by 8-month follow-up after crush stenting for bifurcate lesions.

  9. Three-dimensional reconstruction of coronary stents in vivo based on motion compensated X-ray angiography

    Science.gov (United States)

    Schäfer, Dirk; Movassaghi, Babak; Grass, Michael; Schoonenberg, Gert; Florent, Raoul; Wink, Onno; Klein, Andrew J. P.; Chen, James Y.; Garcia, Joel; Messenger, John C.; Carroll, John D.

    2007-03-01

    The complete expansion of the stent during a percutaneous transluminal coronary angioplasty (PTCA) procedure is essential for treatment of a stenotic segment of a coronary artery. Inadequate expansion of the stent is a major predisposing factor to in-stent restenosis and acute thrombosis. Stents are positioned and deployed by fluoroscopic guidance. Although the current generation of stents are made of materials with some degree of radio-opacity to detect their location after deployment, proper stent expansion is hard to asses. In this work, we introduce a new method for the three-dimensional (3D) reconstruction of the coronary stents in-vivo utilizing two-dimensional projection images acquired during rotational angiography (RA). The acquisition protocol consist of a propeller rotation of the X-ray C-arm system of 180°, which ensures sufficient angular coverage for volume reconstruction. The angiographic projections were acquired at 30 frames per second resulting in 180 projections during a 7 second rotational run. The motion of the stent is estimated from the automatically tracked 2D coordinates of the markers on the balloon catheter. This information is used within a motion-compensated reconstruction algorithm. Therefore, projections from different cardiac phases and motion states can be used, resulting in improved signal-to-noise ratio of the stent. Results of 3D reconstructed coronary stents in vivo, with high spatial resolution are presented. The proposed method allows for a comprehensive and unique quantitative 3D assessment of stent expansion that rivals current X-ray and intravascular ultrasound techniques.

  10. Bioabsorbable scaffolds for the treatment of obstructive coronary artery disease: the next revolution in coronary intervention?

    Science.gov (United States)

    Patel, Niket; Banning, Adrian P

    2013-09-01

    Conventional drug eluting stents allow predictable long-term relief from coronary obstruction in most cases. However, rigid permanent metallic stents alter flow dynamics, abolish vascular reactivity, limit the potential for maximal vasodilation and promote ongoing inflammation and abnormalities of endothelial function. It is hypothesised that they may contribute to mal-apposition of stent struts, accelerated atheroma within the stented segment and perhaps very late stent thrombosis. Dramatic advances in bioabsorbable materials and technology have delivered the potential for a fully absorbable scaffold, which is able to mechanically support the coronary artery, and elute a drug, for a predetermined time period and is then fully absorbed in to the vascular wall. This could permit the 'normalisation' of vascular function, with a number of potential advantages including true normalisation of vasomotor function, restoration of physiological responses to stress/exercise and completion of the vascular response to stenting, without the long-term consequences related to inflammation, accelerated atherosclerosis and thrombosis. Currently, over 16 different scaffolds are at varying stages of development. This review summarises the rationale for the development of absorbable scaffolds and the principal clinical research data.

  11. Aneurysm of the left main coronary artery

    Directory of Open Access Journals (Sweden)

    Ênio E. Guérios

    2000-12-01

    Full Text Available Aneurysm of the left main coronary artery is a rare angiographic finding, with few cases described in the international literature. We report the case of a 42-year-old male with a previous history of acute myocardial infarction, whose coronariography indicated triple vessel coronary disease and an aneurysm of the left main coronary artery. A review of the etiology, clinical aspects, and surgical management of coronary arterial aneurysm is presented.

  12. Preliminary clinical experience in application of rapamycin eluting coronary stent

    Institute of Scientific and Technical Information of China (English)

    HAN Ya-ling; WANG Xiao-zeng; JING Quan-min; WANG Shou-li; MA Ying-yan

    2003-01-01

    @@ Objective To evaluate the safety and feasibility of rapamycin eluring coronary stent(Cyphter). Methods From 2001.12 to 2003.8, there were 80patients received Cypher stent implantation in our hospital. The 68 males and 12 females were aged from 34 to 75(average 58.2 ± 10.7) years old, with AMI in 13 patients, unstable angina pectoris in 43patients and stable angina pectoris in 24 patients.

  13. Preliminary clinical experience in application of rapamycin eluting coronary stent

    Institute of Scientific and Technical Information of China (English)

    HAN Ya-ling; WANG Xiao-zeng; JING Quan-min; WANG Shou-li; MA Ying-yan

    2003-01-01

    @@ Objective To evaluate the safety and feasibility of rapamycin eluting coronary stent(Cypther). Methods From 2001.12 to 2003.8, there were 80 patients received Cypher stent implantation in our hospital. The 68 males and 12 females were aged from 34 to 75 (average 58.2 ± 10.7)years old, with AMI in 13 patients, unstable angina pectoris in 43patients and stable angina pectoris in 24 patients.

  14. Modification of the No-Touch Technique during Renal Artery Stenting

    Directory of Open Access Journals (Sweden)

    John A. Stathopoulos

    2013-01-01

    Full Text Available Renal artery stenting has been established as the primary form of renal artery stenosis revascularization procedure. The no-touch technique is proposed in order to avoid renal artery injury and atheroembolism during renal artery stenting. We describe a modification of the no-touch technique by using an over-the-wire (OTW balloon or a Quickcross catheter with a coronary wire inside, instead of the rigid  J wire. The reported technique, while it prevents direct contact of the guiding catheter with the aortic wall, at the same time it allows for a closer contact with the renal arterial ostium and a more favorable guiding catheter orientation, compared to what is achieved with the use of the more rigid  J wire, thus improving visualization, reducing the amount of contrast required, and potentially decreasing complications.

  15. Minimally invasive coronary artery bypass grafting versus coronary angioplasty for isolated type C stenosis of the left anterior descending artery

    NARCIS (Netherlands)

    Mariani, MA; Boonstra, PW; Grandjean, JG; Monnink, SHJ; denHeijer, P; Crijns, HJGM

    Background: Isolated stenosis of the left anterior descending coronary artery can be treated with medication, percutaneous transluminal coronary angioplasty, or coronary artery bypass grafting. Recently a new treatment has been developed, which is called minimally invasive direct coronary artery

  16. Exercised-Induced Coronary Spasm in Near Normal Coronary Arteries

    Directory of Open Access Journals (Sweden)

    Damian Franzen

    2010-01-01

    Full Text Available In contrast to effort-induced symptoms in obstructive coronary disease, spasm in normal coronary arteries is characterized by angina at rest. We describe a 44-year-old patient with minor coronary plaques and pure exercised-induced coronary spasm. The case questions the differential pathogenic considerations of variant of the variant as opposed to Prinzmetal's variant angina.

  17. [A case of primary coronary artery dissection].

    Science.gov (United States)

    Nishino, M; Kato, J; Ezumi, A; Nozaki, S; Nishino, Y; Tanahashi, H; Yasuno, M; Kobayashi, K; Yamada, Y; Abe, H

    1990-06-01

    Primary coronary artery dissection occurring as a spontaneous event and not associated with trauma due to catheter manipulation is rare. We recently experienced (a case of) a 52-year-old man with primary artery dissection. He was admitted to our hospital with severe chest pain as his chief complaint on September 6, 1988. Electrocardiography and laboratory data showed acute inferior myocardial infarction. He was treated with medication and underwent coronary angiograms on October 3, 1988. Right coronary angiogram revealed an intimal flap and false lumen. But right coronary angiograms 6 months after the onset of myocardial infarction revealed progression of stenosis but no intimal flap, and coronary spasm was not evoked after acetylcholine administration. Primary coronary artery dissection has been reported since Pretty's first description of it in 1931. The majority of earlier cases were diagnosed at autopsy, but recently reports of survivors have been increasing due to the progress in and popularization of coronary angiographic technics. This case is the 46th case of primary coronary dissection found by coronary angiography. So it is not extremely rare. In our case the involved artery was the right coronary artery. In survivors, right coronary artery dissection is more frequent than left, because the area supplied by the right coronary artery is smaller than the area supplied by the left one. Although in our case coronary artery stenosis progressed, after a long term resolution of dissection may occur. There are a few cases in which resolution of dissection occurred naturally.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Coronary Artery and Pulmonary Artery Fistula Originated from Significant Stenosis in the Left Anterior Descending Artery

    Directory of Open Access Journals (Sweden)

    Alper Sami Kunt

    2013-01-01

    Full Text Available Coronary artery fistula (CAF is defined as a rare anomalous connection between a coronary artery and a major vessel or a cardiac chamber. We report a case of a left anterior descending coronary (LAD stenosis and coronary artery fistula between the LAD coronary artery and the pulmonary artery (PA. CAF is often diagnosed by coronary angiogram. We describe our diagnostic approach and review the literature on the epidemiology, the pathophysiology, the diagnostic modalities, and the treatment options.

  19. A Novel Tram Stent Method in the Treatment of Coronary Bifurcation Lesions - Finite Element Study.

    Directory of Open Access Journals (Sweden)

    Mark C Arokiaraj

    Full Text Available A novel stent was designed for the treatment of coronary bifurcation lesion, and it was investigated for its performance by finite element analysis. This study was performed in search of a novel method of treatment of bifurcation lesion with provisional stenting. A bifurcation model was created with the proximal vessel of 3.2 mm diameter, and the distal vessel after the side branch (2.3 mm was 2.7 mm. A novel stent was designed with connection links that had a profile of a tram. Laser cutting and shape setting of the stent was performed, and thereafter it was crimped and deployed over a balloon. The contact pressure, stresses on the arterial wall, stresses on the stent, the maximal principal log strain of the main artery and the side-branch were studied. The study was performed in Abaqus, Simulia. The stresses on the main branch and the distal branch were minimally increased after deployment of this novel stent. The side branch was preserved, and the stresses on the side branch were lesser; and at the confluence of bifurcation on either side of the side branch origin the von-Mises stress was marginally increased. The stresses and strain at the bifurcation were significantly lesser than the stresses and strain of the currently existing techniques used in the treatment of bifurcation lesions though the study was primarily focused only on the utility of the new technology. There is a potential for a novel Tram-stent method in the treatment of coronary bifurcation lesions.

  20. A finite element study of balloon expandable stent for plaque and arterial wall vulnerability assessment

    Science.gov (United States)

    Karimi, Alireza; Navidbakhsh, Mahdi; Razaghi, Reza

    2014-07-01

    The stresses induced within plaque tissues and arterial layers during stent expansion inside an atherosclerotic artery can be exceeded from the yield stresses of those tissues and, consequently, lead to plaque or arterial layer rupture. The distribution and magnitude of the stresses in each component involved in stenting might be clearly different for different plaque types and different arterial layers. In this study, a nonlinear finite element simulation was employed to investigate the effect of plaque composition (calcified, cellular, and hypocellular) on the stresses induced in the arterial layers (intima, media, and adventitia) during implantation of a balloon expandable coronary stent into a stenosed artery. The atherosclerotic artery was assumed to consist of a plaque and normal/healthy arterial tissues on its outer side. The results indicated a significant influence of plaque types on the maximum stresses induced within the plaque wall and arterial layers during stenting but not when computing maximum stress on the stent. The stress on the stiffest calcified plaque wall was in the fracture level (2.38 MPa), whereas cellular and hypocellular plaques remain stable owing to less stress on their walls. Regardless of plaque types, the highest von Mises stresses were observed on the stiffest intima layer, whereas the lowest stresses were seen to be located in less stiff media layer. The computed stresses on the intima layer were found to be high enough to initiate a rupture in this stiff layer. These findings suggest a higher risk of arterial vascular injury for the intima layer, while a lower risk of arterial injury for the media and adventitia layers.

  1. Acute Limb Ischemia and Coronary Artery Disease in a Case of Kimura’s Disease

    Science.gov (United States)

    Heo, Woon; Jun, Hee Jae; Kang, Do Kyun; Min, Ho-Ki; Hwang, Youn-Ho; Kim, Ji Yong; Nam, Kyung Han

    2017-01-01

    Kimura disease (KD) is an immune-mediated chronic inflammatory disease of unknown etiology. KD has many complications associated with hypereosinophilia, including various forms of allergic reactions and eosinophilic lung disease. Additionally, hypereosinophilia is associated with hypercoagulability, which may lead to thromboembolic events. A 36-year-old man with KD presented with acute limb ischemia and coronary artery occlusion. He underwent thrombectomy, partial endarterectomy of both popliteal arteries, and coronary artery stent insertion. KD is a systemic disease that affects many organs and presents with thromboembolism and vasculitis. In a patient with KD, physicians should evaluate the vascular system, including the coronary arteries. PMID:28382271

  2. Morphology characterization and biocompatibility study of PLLA (Poly-L-Llactid-Acid) coating chitosan as stent for coronary heart disease

    Science.gov (United States)

    Widiyanti, Prihartini; Paramadini, Adanti W.; Jabbar, Hajria; Fatimah, Inas; Nisak, Fadila N. K.; Puspitasari, Rahma A.

    2016-03-01

    Cardiovascular disease is a global disease with high urgency. In the severe case of coronary heart disease while a blockage in the coronary arteries reach 75% or more, the patient required stent implantation. Stents are made of metal which has many limitations that can lead to blood clots and stent incompatibility toward the size of the blood vessels. There is a metal stent replacement solution that made from polymer material which is biocompatible. PLLA also has biocompatibility and good mechanical strength. PLLA stent will be coated with chitosan as a candidate for drug-coated stents which is able to work as a drug carrier. The aim of this study is to know the morphology information and biocompability status of PLLA coating chitosan as candidate of heart stent. Morphological results using SEM showed a smooth surface structure which reinforced clinical standard of stent material. Results of cytotoxicity test by MTT Assay method showed that the result of four samples in this experiment living cells is reached 90% which is non toxic and safe to use in the human body. %). The conclusion of this study is PLLA is polymer has potency to be used as stent material.

  3. The primary percutaneous coronary intervention for acute anterior myocardial infarction in a middle-aged male patient with bilateral coronary artery to pulmonary artery fistulas.

    Science.gov (United States)

    Altay, Servet; Cakmak, Huseyin Altug; Velibey, Yalcin; Erer, Betul

    2012-11-14

    A 38-year-old man admitted to emergency department with 2 h of typical substernal chest pain, shortness of breath and nausea. The ECG revealed sinus rhythm with a 3 mm ST elevation in precordial leads V1-V6. The coronary angiography revealed acute total occlusion in left anterior descending artery (LAD) with normal circumflex and right coronary artery (RCA) along with bilateral fistulas arising from the proximal LAD and ostial RCA draining into the main pulmonary artery. Therefore, primary percutaneous coronary intervention and bare metal stent implantation was performed to culprit LAD lesion. The electrocardiographically gated 64-slice multidetector-row CT showed two large, tortuous abnormal vessels which arose from the both ostial part of the RCA and LAD draining into the main pulmonary artery. We report an unusual case of bilateral coronary artery to pulmonary artery fistulas leading to acute anterior myocardial infarction in a middle-aged male patient.

  4. Diagnosis and treatment of spontaneous coronary artery pseudoaneurysm: Rare anomaly with potentially significant clinical implications.

    Science.gov (United States)

    Kar, Subrata; Webel, Richard R

    2017-03-04

    Spontaneous coronary artery pseudoaneurysm (PSA, false aneurysm) is an extremely rare occurrence with the precise incidence unknown. It is defined as an outwardly bulging monolayer or double layer within the coronary artery that lacks all 3 layers (intima, media, and adventitia) of the arterial wall. Coronary PSA commonly occurs from arterial dissection or perforation induced by catheter intervention, infection, pregnancy, or trauma. Traumatic dissection or perforation of the coronary artery after a percutaneous coronary intervention (PCI) remains the most common cause. Such cases may progress to myocardial ischemia, acute myocardial infarction, or acute coronary artery rupture causing death from cardiac tamponade. Intravascular ultrasound or cardiac computed tomography may aid in the diagnosis. Treatment options include PCI with a covered stent, bare or drug-eluting stent, coil embolization, coronary artery bypass graft with isolation of the PSA, or conservative management with vigilant clinical follow-up. In this review, we sought to describe the diagnosis, etiology, treatment, and the limited literature on spontaneous coronary artery PSA. © 2017 Wiley Periodicals, Inc.

  5. Influence of strut cross-section of stents on local hemodynamics in stented arteries

    Science.gov (United States)

    Jiang, Yongfei; Zhang, Jun; Zhao, Wanhua

    2016-05-01

    Stenting is a very effective treatment for stenotic vascular diseases, but vascular geometries altered by stent implantation may lead to flow disturbances which play an important role in the initiation and progression of restenosis, especially in the near wall in stented arterial regions. So stent designs have become one of the indispensable factors needed to be considered for reducing the flow disturbances. In this paper, the structural designs of strut cross-section are considered as an aspect of stent designs to be studied in details. Six virtual stents with different strut cross-section are designed for deployments in the same ideal arterial model. Computational fluid dynamics (CFD) methods are performed to study how the shape and the aspect ratio (AR) of strut cross-section modified the local hemodynamics in the stented segments. The results indicate that stents with different strut cross-sections have different influence on the hemodynamics. Stents with streamlined cross-sectional struts for circular arc or elliptical arc can significantly enhance wall shear stress (WSS) in the stented segments, and reduce the flow disturbances around stent struts. The performances of stents with streamlined cross-sectional struts are better than that of stents with non-streamlined cross-sectional struts for rectangle. The results also show that stents with a larger AR cross-section are more conductive to improve the blood flow. The present study provides an understanding of the flow physics in the vicinity of stent struts and indicates that the shape and AR of strut cross-section ought to be considered as important factors to minimize flow disturbance in stent designs.

  6. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Matthias C. Burg

    2011-01-01

    Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  7. Renal function after renal artery stenting

    Institute of Scientific and Technical Information of China (English)

    George S. Hanzel; Mark Downes; Peter A. McCullough

    2005-01-01

    @@ Atherosclerotic renal artery stenosis (ARAS), a common clinical finding, is increasing in prevalence as the population ages. ARAS is seen in ~ 7% of persons over 65 years of age1 and in ~ 20% of patients at the time of coronary angiography.2 It is an important cause of chronic kidney disease and may result in 11-14% of cases of end stage renal disease.3

  8. Anomalous Coronary Artery: Run of a Lifetime.

    Science.gov (United States)

    Green, Michael Stuart; Sehgal, Sankalp; Smukler, Naomi; Suber, LaDouglas Jarod; Saththasivam, Pooven

    2016-09-01

    The anatomy of the coronary circulation is well described with incidence of congenital anomalies of approximately 0.3% to 1.0%. Although often incidental, 20% are life-threatening. A 25-year-old woman with syncopal episodes collapsed following a 10-km run. Coronary anatomy evaluation showed an anomalous left main coronary artery originating from the right sinus of valsalva and following a course between the aorta and the pulmonary outflow tract. Percutaneous coronary intervention was followed by eventual surgical revascularization. Abnormal course of coronary arteries plays a role in the pathogenesis of sudden death on exertion. Origin of the left main coronary from the right sinus of valsalva is a rare congenital anomaly. The expansion of the roots of the aorta and pulmonary trunk with exertion lead to compression of the coronary artery and syncope. Our patient raises awareness of a potentially fatal coronary artery path. Intraoperative identification of anomalous coronaries by utilizing intraoperative transesophageal echocardiography was critical.

  9. A Rare Case of Triple Coronary Artery Fistulae Originating from Left Main and Right Coronary Arteries

    Directory of Open Access Journals (Sweden)

    Mehmet Ali Elbey

    2012-10-01

    Full Text Available ABSTRACTDual coronary artery fistulae (CAF involving both right and left coronary trees are uncommon; accounting for only 5% of all CAFs. A 48-year-old male patient was admitted to our institution for evaluation of chest pain. The coronary angiography revealed fistulae from left main coronary artery (LMCA and right coronary artery (RCA to the pulmonary artery. We concluded that angina pectoris was caused by a steal phenomenon and the patient was recommended surgical intervention. To our knowledge, this is the first paper reporting three fistulae associated with multiple aneurysms originating from proximal coronary arteries, which were connected to the pulmonary artery.

  10. Newest-generation drug-eluting and bare-metal stents combined with prasugrel-based antiplatelet therapy in large coronary arteries

    DEFF Research Database (Denmark)

    Jeger, Raban; Pfisterer, Matthias; Alber, Hannes

    2012-01-01

    In the BAsel Stent Kosten Effektivitäts Trial PROspective Validation Examination (BASKET-PROVE), drug-eluting stents (DESs) had similar 2-year rates of death and myocardial infarction but lower rates of target vessel revascularization and major adverse cardiac events compared with bare-metal sten...... (BMSs). However, comparative clinical effects of newest-generation DES with biodegradable polymers vs second-generation DES or newest-generation BMS with biocompatible coatings, all combined with a prasugrel-based antiplatelet therapy, on 2-year outcomes are not known....

  11. Flow Characteristics Near to Stent Strut Configurations on Femoropopliteal Artery

    Science.gov (United States)

    Paisal, Muhammad Sufyan Amir; Fadhil Syed Adnan, Syed; Taib, Ishkrizat; Ismail, Al Emran; Kamil Abdullah, Mohammad; Nordin, Normayati; Seri, Suzairin Md; Darlis, Nofrizalidris

    2017-08-01

    Femoropopiteal artery stenting is a common procedure suggested by medical expert especially for patient who is diagnosed with severe stenosis. Many researchers reported that the growth of stenosis is significantly related to the geometry of stent strut configuration. The different shapes of stent geometry are presenting the different flow pattern and re-circulation in stented femoropopliteal artery. The blood flow characteristics near to the stent geometry are predicted for the possibility of thrombosis and atherosclerosis to be formed as well as increase the growth of stenosis. Thus, this study aims to determine the flow characteristic near to stent strut configuration based on different hemodynamic parameters. Three dimensional models of stent and simplified femoropopliteal artery are modelled using computer aided design (CAD) software. Three different models of stent shapes; hexagon, circle and rectangle are simulated using computational fluid dynamic (CFD) method. Then, parametric study is implemented to predict the performance of stent due to hemodynamic differences. The hemodynamic parameters considered are pressure, velocity, low wall shear stress (WSSlow) and wall shear stress (WSS). From the observation, flow re-circulation has been formed for all simulated stent models which the proximal region shown the severe vortices. However, rectangular shape of stent strut (Type P3) shows the lowest WSSlow and the highest WSS between the range of 4 dyne/cm2 and 70 dyne/cm2. Stent Type P3 also shows the best hemodynamic stent performance as compare to others. In conclusion, Type P3 has a favourable result in hemodynamic stent performance that predicted less probability of thrombosis and atherosclerosis to be formed as well as reduces the growth of restenosis.

  12. Coronary Stent Materials and Coatings: A Technology and Performance Update.

    Science.gov (United States)

    O'Brien, Barry; Zafar, Haroon; Ibrahim, Ahmad; Zafar, Junaid; Sharif, Faisal

    2016-02-01

    This paper reviews the current state of the art for coronary stent materials and surface coatings, with an emphasis on new technologies that followed on from first-generation bare metal and drug-eluting stents. These developments have been driven mainly by the need to improve long term outcomes, including late stent thrombosis. Biodegradable drug-eluting coatings aim to address the long term effects of residual durable polymer after drug elution; the SYNERGY, BioMatrix, and Nobori stents are all promising devices in this category, with minimal polymer through the use of abluminal coatings. Textured stent surfaces have been used to attached drug directly, without polymer; the Yukon Choice and BioFreedom stents have some promising data in this category, while a hydroxyapatite textured surface has had less success. The use of drug-filled reservoirs looked promising initially but the NEVO device has experienced both technical and commercial set-backs. However this approach may eventually make it to market if trials with the Drug-Filled Stent prove to be successful. Non-pharmacological coatings such as silicon carbide, carbon, and titanium-nitride-oxide are also proving to have potential to provide better performance than BMS, without some of the longer term issues associated with DES. In terms of biological coatings, the Genous stent which promotes attachment of endothelial progenitor cells has made good progress while gene-eluting stents still have some practical challenges to overcome. Perhaps the most advancement has been in the field of biodegradable stents. The BVS PLLA device is now seeing increasing clinical use in many complex indications while magnesium stents continue to make steady advancements.

  13. Effect of gender differences on early and mid-term clinical outcome after percutaneous or surgical coronary revascularisation in patients with multivessel coronary artery disease: Insights from ARTS i and ARTS II

    NARCIS (Netherlands)

    S. Vaina (Sophia); V. Voudris; M-C. Morice (Marie-Claude); B. de Bruyne (Bernard); A. Colombo (Antonio); C.M. Miguel (Carlos); G. Richard (Gert); J. Fajadet (Jean); C.W. Hamm (Christian); M. Schuijer (Monique); N. Macours; H.P. Stoll; D.V. Cokkinos (Dennis); C. Stefanadis (Christodoulos); P.W.J.C. Serruys (Patrick)

    2009-01-01

    textabstractAims: The aim of the current study was to compare the short and mid-term outcome between males and females treated with percutaneous coronary intervention (PCI) with bare metal stent implantation or coronary artery bypass graft (CABG) surgery and drug-eluting stent implantation in the Ar

  14. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II)

    DEFF Research Database (Denmark)

    Serruys, Patrick W; Chevalier, Bernard; Sotomi, Yohei

    2016-01-01

    BACKGROUND: No medium-term data are available on the random comparison between everolimus-eluting bioresorbable vascular scaffolds and everolimus-eluting metallic stents. The study aims to demonstrate two mechanistic properties of the bioresorbable scaffold: increase in luminal dimensions as a re...

  15. Early severe coronary artery disease and aortic coarctation in a child with familial hypercholesterolaemia.

    Science.gov (United States)

    Labib, Dina; Soliman, Haytham; Said, Kareem; Sorour, Khaled

    2016-11-30

    An 11-year-old boy presented with easy fatigability, multiple xanthomas, and absent pedal pulsations. Laboratory workup showed severe hypercholesterolaemia and non-invasive imaging revealed 'normally functioning' bicuspid aortic valve and tight aortic coarctation. Coronary angiography showed severe right coronary artery (RCA) stenosis. Medical treatment resulted in significant improvement of dyslipidaemia. We successfully performed balloon dilation and stenting of his coarctation, as well as percutaneous coronary intervention for RCA lesion.

  16. Irradiation and dosimetry of Nitinol stent for renal artery brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Arbabi, Azim [Science and Research Campus, Islamic Azad University, P.O. Box 14515-775, Tehran (Iran, Islamic Republic of); Shahid Beheshti Medical University, P.O. Box 14335-1419, Tehran (Iran, Islamic Republic of); Sadeghi, Mahdi [Science and Research Campus, Islamic Azad University, P.O. Box 14515-775, Tehran (Iran, Islamic Republic of); Nuclear Medicine Research Group, Agricultural, Medical and Industrial Research School, P.O. Box 31485-498, Karaj (Iran, Islamic Republic of)], E-mail: msadeghi@nrcam.org; Joharifard, Mahdi [Science and Research Campus, Islamic Azad University, P.O. Box 14515-775, Tehran (Iran, Islamic Republic of)

    2009-01-15

    This study was conducted to assess the suitability of {sup 48}V radioactive stent for use in renal artery brachytherapy. A nickel-titanium alloy Nitinol stent was irradiated over the proton energy range of up to 8.5 MeV, to obtain {sup 48}V. The depth dose distribution analysis of the activated stent was done with TLD-700GR in a Perspex phantom. We investigated a unique mixed gamma/beta brachytherapy source of {sup 48}V. For a 10 mm outer-diameter {sup 48}V stent, the average measured dose rate to vessel was 37 mGy/h. The dosimetry results of the {sup 48}V stent suggest that the stent is suitable for use in renal artery brachytherapy.

  17. Investigation of long-term implantation of BuMA stent in a porcine coronary model

    Institute of Scientific and Technical Information of China (English)

    CHEN Ming; WANG Xin-gang; ZHENG Bo; PENG Hong-yu; Zhang Xiao-yan; ZHANG Bin; HUO Yong

    2012-01-01

    Background Stent-based delivery of sirolimus has been shown to reduce neointimal hyperplasia significantly.However,the long-term effect of the polymer is thought to initiate and sustain an inflammatory response and contribute to the occurrence of late complications.Our study aimed to evaluate the efficacy and safety of the BuMA biodegradable drug-coated sirolimus-eluting stent(BSES)for inhibiting neointimal hyperplasia in a porcine coronary model.Methods Four types of stents were implanted at random in different coronary arteries of the same pig:BSES(n=24),bare metal stent(BMS)(n=24),biodegradable polymer coated stent without drug(PCS)(n=24)and only poly(n-butyl methacrylate)base layer coated stent(EGS)(n=23).In total,26 animals underwent successful random placement of 95 oversized stents in the coronary arteries.Coronary angiography was performed after 28 days,90 days and 240 days of stent implantation.After 14 days,28 days,90 days and 240 days,6 animals at each timepoint were sacrificed for histomorphologic analysis.Results The 28-day,90-day and 240-day results of quantitative coronary angiography(QCA)showed reduction in luminal loss(LL)in the BSES group when compared with the BMS group;(0.20±0.35)mm vs.(0.82±0.51)mm(P=0.035),(0.20±0.30)mm vs.(0.93±0.51)mm(P=0.013),and(0.18±0.16)mm vs.(0.19±0.24)mm(P=0.889),respectively.By 28-day,90-day and 240-day histomorphomeric analysis results,there was also a corresponding significant reduction in neointimal tissue proliferation with similar injury scores of BSES compared with the BMS control;average neointimal area(0.90±0.49)mm2 vs.(2.16±1.29)mm2(P=0.049),(1.53±0.84)mm2 vs.(3.41±1.55)mm2(P=0.026),and(2.43±0.95)mm2 vs.(3.12±1.16)mm2(P=0.228),respectively.High magnification histomorphologic examination revealed similar inflammation scores and endothelialization scores in both the BSES and BMS groups.Conclusions The BuMA biodegradable drug-coated sirolimus-eluting stents can significantly reduce neointimal

  18. Percutaneous coronary intervention with anomalous origin of right coronary artery: case reports and literature review

    Institute of Scientific and Technical Information of China (English)

    Li-Feng Hong; Song-Hui Luo; Jian-Jun Li

    2013-01-01

    Percutaneous coronary intervention (PCI) in an anomalous right coronary artery (RCA) can be technically difficult because selective cannulation of the vessel may not be easy. We thereby present two cases with unstable angina pectoris of anomalous originated RCA. The PCI were successfully performed in two patients with a special guiding wire manipulating skill which we called "gone with the flow" combined with balloon anchoring technology, providing excellent angiographic visualization and sound guide support for stent delivery throughout the procedure without severe cardiovascular adverse effects. Our primary data suggested that PCI for geriatric patients with an anomalous origin of RCA accompanied by severe atherosclerotic lesions might also be a safe, available, and feasible strategy.

  19. Clinical outcomes of "complete, partially complete, and incomplete" revascularisation at five-year follow-up after percutaneous intervention of unprotected left main coronary artery disease with drug-eluting stents.

    Science.gov (United States)

    Zhang, Yao-Jun; Iqbal, Javaid; Xu, Bo; Ye, Fei; Zhang, Jun-Jie; Bourantas, Christos V; Pan, Dao-Rong; Tian, Nai-Liang; Kan, Jing; Qian, Xue-Song; Ding, Shi-Qing; Li, Feng; Zhang, Ai-Ping; Liu, Yue-Qiang; Muramatsu, Takashi; Onuma, Yoshinobu; Garcia-Garcia, Hector M; Serruys, Patrick W; Chen, Shao-Liang

    2016-10-10

    The study aimed to examine five-year clinical outcomes of complete (CR), partially complete (PCR), and incomplete revascularisation (ICR) in patients with unprotected left main coronary artery (ULMCA) disease treated with drug-eluting stents (DES). Completeness of revascularisation, defined as revascularisation of all vessels ≥1.5 or 2.5 mm in diameter, has been shown to correlate with outcomes after percutaneous coronary intervention (PCI). There are no data to compare revascularisation strategies on long-term clinical outcomes in patients undergoing PCI of ULMCA disease. This prospective registry enrolled 910 consecutive patients with ULMCA disease undergoing PCI with DES implantation. CR included patients who had a successful revascularisation of all diseased segments with diameter ≥1.5 mm. PCR included patients who had successful revascularisation of all diseased segments with diameter ≥2.5 mm. ICR included patients who did not achieve revascularisation for all diseased segments of diameter ≥2.5 mm. The primary endpoint was the incidence of major adverse cardiac events (MACE: a composite of cardiac death, myocardial infarction and repeat revascularisation) at five-year follow-up. CR was achieved in 386 (42.4%), PCR in 227 (25.0%), and ICR in 297 (32.6%) patients. Patients with ICR had a significantly higher rate of MACE (29.6% vs. 22.5% and 15.5%, pfive-year follow-up. After propensity score matching, patients with CR vs. PCR had similar incidences of MACE (hazard ratio [HR]: 1.16, 95% confidence interval [CI]: 0.78-1.74, p=0.46), mortality (HR: 1.27, 95% CI: 0.61-2.63, p=0.53), and cardiac death (1.8% vs. 4.5%; HR: 2.56, 95% CI: 0.80-8.17, p=0.11). On multivariable logistic regression analysis, ICR appears to be an outcome of poor clinical characteristics, comorbidities and complex coronary anatomy. In the treatment of patients with ULMCA disease, ICR was associated with worse long-term clinical outcomes than CR and PCR. PCR has clinical outcomes

  20. Cognitive changes after carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Politi, M.; Struffert, T.; Krick, C.; Backens, M. [University of the Saarland, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Supprian, T.; Falkai, P.; Reith, W. [University of the Saarland, Clinic for Psychiatry and Psychotherapy, Homburg (Germany)

    2006-05-15

    We aimed to test changes in cognitive performance after carotid artery stenting (CAS). Ten patients were neuropsychologically tested at least 24 h before and 48 h after CAS. To diminish thromboembolic events, we used a proximal protection device. The following neuropsychological tests were selected: The Mini Mental State Examination (MMSE), symbol digit test and subtests of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) battery (verbal fluency, constructional practice, word list memory and delayed recall). Affective state was determined by the Beck Depression Score (BDS). No patient suffered from depression (BDS <1) or dementia (MMSE 29.9{+-}1.5). Nine of the ten patients (P=0.12) showed increased speed in the Number Connection Test (NCT) (corresponding to trail making test). Most patients showed better or similar results concerning delayed recall (P=0.31). No change was observed in the symbol digit test, word list memory, verbal fluency or constructional practice. Better results concerning NCT and delayed recall after carotid stenting might be due to improved brain perfusion. After CAS, cognitive and memory performance seem to improve. Further studies with different time intervals and more refined testing, as well as perfusion-weighted imaging, are needed. (orig.)

  1. Multivariate Analysis of Clinical Factors in Restenosis after Coronary Stenting

    Institute of Scientific and Technical Information of China (English)

    Wen Shangyu; Mao Jieming; Guo Liiun; Zhao Yiming; Zhang Fuchun; Guo Jingxlan; Cheng Mingzhe

    2000-01-01

    Ojbective To find the independent predictors for restenosis after coronary stenting.Methods Quantitative angiography was performed on 60 cases (67 successfully dilated lesions) after angioplasty over 6-months follow-up, and both univariate and multivariate logistic regression analysis were done to identify the correlations of restenosis with clinical factors. Results The total restenosis rate was 31.3%(21 of 67 lesions), and according to univariate analysis the patients who underwent coronary stenting ≥3.5mm had a lower rate of restenosis ( P < 0. 01).Collateral circulation to the obstruction site, high maximal inflation pressure, smoking and the less minimal lumen diameter after PTCA made the rate of restenosis higherower ( P < 0.05) . Multivariate logistic regression analysis showed that coronary stenting ≥ 3.5mm had a low rate of restenosis, but high maximal inflation pressure and smoking made the restenosis rate higher. Conclusion Coronary stent size, maximal inflation pressure and. smoking were independent predictors for restenosis.

  2. Successful management of dislodged stents during percutaneous coronary intervention.

    Science.gov (United States)

    Farman, Muhammad Tariq; Sial, Jawaid Akbar; Saghir, Tahir; Rizvi, Syed Nadeem Hasan; Rasool, Syed Ishtiaq; Jamal, Syed Zahid

    2010-02-01

    Stent dislodgement is a very rare but recognized and potentially serious complication of percutaneous coronary intervention (PCI). This case series describe the incidence and etiology of such cases at National Institute of Cardiovascular Diseases, Karachi during the year 2008 and the method of treatment of this complication.

  3. Accuracy of electrocardiographic-gated versus nongated volumetric intravascular ultrasound measurements of coronary arterial narrowing

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per

    2007-01-01

    Intravascular ultrasound (IVUS) allows precise measurements of plaque plus media (P+M) volume and neointimal hyperplasia after coronary artery stenting. Conventional IVUS volumetric analysis is performed mostly without electrocardiographically gated acquisition, and the IVUS images are selected...... in changes between 2 electrocardiographically gated and 2 nongated pullbacks (lumen: 0.37 +/- 1.76 vs -0.23 +/- 2.32 mm(3), p = NS; EEM: 0.25 +/- 3.22 vs -0.94 +/- 4.27 mm(3), p = NS; P+M: -0.18 +/- 3.42 vs -0.74 +/- 3.88 mm(3), p = NS). In conclusion, in moderate atherosclerotic or stented coronary arteries...

  4. Coated stents to prevent restenosis in coronary heart disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2005-11-01

    Full Text Available Background: In-stent-restenosis (ISR is considered to be an essential limiting factor of stenting in coronary heart disease (CHD. The development of coated stents has raised expectations on substantial lowering restenosis after stenting with decreasing the rate of restenosis and a reduction in the rate of clinical events. Objectives: The present analysis addresses the questions on medical effectiveness and cost-effectiveness of the use of various coated stent types in CHD. Methods: The literature was searched in December 2004 in the most relevant medical and economic databases. The medical evaluation was conducted on the basis of published RCT. The data from the studies regarding various angiographic, sonographic and clinical endpoints were checked for methodical quality and summarised in meta-analyses. Within the scope of economic evaluation the primary studies were analysed and modelling was performed, applying clinical effect estimates from the meta-analyses of the medical evaluation and current estimates of German costs. Results: Medical evaluation: Ten different stenttypes were used in the included 26 RCT. The results for heparin, silicon-carbide, carbon and PTFE coated stenttypes could not reveal any significant differences between the medical effectiveness of coated and uncoated stents. The application of sirolimus, paclitaxel, everolimus and 7-hexanoyltaxol eluting stents showed a significant lower restenosis at 6-9 months with decrease in the rate of restenosis for polymer-based sirolimus, paclitaxel and 7-hexanoyltaxol eluting stents. In contrast, the use of gold-coated and actinomycin-D eluting stents was associated with a significantly higher restenosis. The polymer-based sirolimus and paclitaxel eluting stents also showed a significant and considerable reduction in the rate of repeated percutaneous revascularisations at 6-12 months (3.5% vs. 19.7%; p<0.0001, RR=0.19 [95%CI: 0.11; 0.33] and 3.5% vs. 12.2%; p<0.0001, RR=0.30 [95%CI: 0

  5. Technical options for treatment of in-stent restenosis after carotid artery stenting

    NARCIS (Netherlands)

    Pourier, Vanessa E C; de Borst, Gert J.

    2016-01-01

    Objective This review summarizes the available evidence and analyzes the current trends on treatments for carotid in-stent restenosis (ISR) after carotid artery stenting (CAS). Methods An update of a 2010 review of the literature (which included 20 articles) was conducted using PubMed and Embase. Al

  6. Frequency and consequences of early in-stent lesions after carotid artery stent placement.

    NARCIS (Netherlands)

    Jongen, L.M.; Hendrikse, J.; Waaijer, A.; Worp, H.B. van der; Leijdekkers, V.J.; Lo, R.T.; Mali, W.P.Th.; Prokop, M.

    2009-01-01

    PURPOSE: To examine the prevalence of in-stent lesions 1 month after carotid artery stent placement with multidetector computed tomography (CT) angiography and to evaluate their possible causes and their consequences during 1-year follow-up. MATERIALS AND METHODS: Sixty-nine patients with symptomati

  7. Clinical outcomes in low risk coronary artery disease patients treated with different limus-based drug-eluting stents--a nationwide retrospective cohort study using insurance claims database.

    Directory of Open Access Journals (Sweden)

    Chao-Lun Lai

    Full Text Available The clinical outcomes of different limus-based drug-eluting stents (DES in a real-world setting have not been well defined. The aim of this study was to investigate the clinical outcomes of three different limus-based DES, namely sirolimus-eluting stent (SES, Endeavor zotarolimus-eluting stent (E-ZES and everolimus-eluting stent (EES, using a national insurance claims database. We identified all patients who received implantation of single SES, E-ZES or EES between January 1, 2007 and December 31, 2009 from the National Health Insurance claims database, Taiwan. Follow-up was through December 31, 2011 for all selected clinical outcomes. The primary end-point was all-cause mortality. Secondary end-points included acute coronary events, heart failure needing hospitalization, and cerebrovascular disease. Cox regression model adjusting for baseline characteristics was used to compare the relative risks of different outcomes among the three different limus-based DES. Totally, 6584 patients were evaluated (n=2142 for SES, n=3445 for E-ZES, and n=997 for EES. After adjusting for baseline characteristics, we found no statistically significant difference in the risk of all-cause mortality in three DES groups (adjusted hazard ratio [HR]: 1.14, 95% confidence interval [CI]: 0.94-1.38, p=0.20 in E-ZES group compared with SES group; adjusted HR: 0.77, 95% CI: 0.54-1.10, p=0.15 in EES group compared with SES group. Similarly, we found no difference in the three stent groups in risks of acute coronary events, heart failure needing hospitalization, and cerebrovascular disease. In conclusion, we observed no difference in all-cause mortality, acute coronary events, heart failure needing hospitalization, and cerebrovascular disease in patients treated with SES, E-ZES, and EES in a real-world population-based setting in Taiwan.

  8. Clinical outcomes in low risk coronary artery disease patients treated with different limus-based drug-eluting stents--a nationwide retrospective cohort study using insurance claims database.

    Science.gov (United States)

    Lai, Chao-Lun; Wu, Ching-Fen; Kuo, Raymond Nien-Chen; Yang, Yen-Yun; Chen, Ming-Fong; Chan, K Arnold; Lai, Mei-Shu

    2015-01-01

    The clinical outcomes of different limus-based drug-eluting stents (DES) in a real-world setting have not been well defined. The aim of this study was to investigate the clinical outcomes of three different limus-based DES, namely sirolimus-eluting stent (SES), Endeavor zotarolimus-eluting stent (E-ZES) and everolimus-eluting stent (EES), using a national insurance claims database. We identified all patients who received implantation of single SES, E-ZES or EES between January 1, 2007 and December 31, 2009 from the National Health Insurance claims database, Taiwan. Follow-up was through December 31, 2011 for all selected clinical outcomes. The primary end-point was all-cause mortality. Secondary end-points included acute coronary events, heart failure needing hospitalization, and cerebrovascular disease. Cox regression model adjusting for baseline characteristics was used to compare the relative risks of different outcomes among the three different limus-based DES. Totally, 6584 patients were evaluated (n=2142 for SES, n=3445 for E-ZES, and n=997 for EES). After adjusting for baseline characteristics, we found no statistically significant difference in the risk of all-cause mortality in three DES groups (adjusted hazard ratio [HR]: 1.14, 95% confidence interval [CI]: 0.94-1.38, p=0.20 in E-ZES group compared with SES group; adjusted HR: 0.77, 95% CI: 0.54-1.10, p=0.15 in EES group compared with SES group). Similarly, we found no difference in the three stent groups in risks of acute coronary events, heart failure needing hospitalization, and cerebrovascular disease. In conclusion, we observed no difference in all-cause mortality, acute coronary events, heart failure needing hospitalization, and cerebrovascular disease in patients treated with SES, E-ZES, and EES in a real-world population-based setting in Taiwan.

  9. Transcatheter stenting of arterial duct in duct-dependent congenital heart disease

    Directory of Open Access Journals (Sweden)

    Đukić Milan

    2013-01-01

    Full Text Available Introduction. Critical congenital heart diseases (CHD are mostly duct-dependent and require stable systemic-pulmonary communication. In order to maintain patency of the ductus arteriosus (DA, the first line treatment is Prostaglandin E1 and the second step is the surgical creation of aortic-pulmonary shunt. To reduce surgical risk in neonates with the critical CHD, transcatheter stenting of DA can be performed in selected cases. Case Outline. A four-month old infant was diagnosed with the pulmonary artery atresia with ventricular septal defect (PAA/VSD. The left pulmonary artery was perfused from DA, and the right lung through three major aortopulmonary collaterals (MAPCAs. A coronary stent was placed in the long and critically stenotic DA, with final arterial duct diameter of 3.5 mm, and significantly increased blood supply to the left lung. After the procedure, the infant’s status was improved with regard to arterial oxygen saturation, feeding and weight gain. During the follow-up, one year later, aortography revealed in-stent stenosis. The left pulmonary artery, as well as the branches, was well-developed and the decision was made to proceed with further surgical correction. Conclusion. Stenting of DA can be an effective alternative to primary surgical correction in selected patients with duct-dependent CHD.

  10. Emergency off-pump coronary artery surgery

    Institute of Scientific and Technical Information of China (English)

    Shahzad G Raja; Zulfiqar Haider; Haider Zaman

    2004-01-01

    Background Off-pump coronary artery bypass grafting is fast-becoming a procedure of choice for elective revascularization in high-risk patients with multi-vessel coronary artery disease. However, the role of off-pump coronary artery bypass grafting for patients with acute coronary syndromes requiring emergency revascularization still requires validation. We present our experience to show the feasibility of off-pump coronary artery surgery as an emergency revascularization technique. Methods From April 2001 to September 2003, emergency (operation within 24 hours after hospitalization) coronary artery bypass grafting without cardiopulmonary bypass (CPB) was performed in 66 patients with a mean age of (66.9±5.4) years (range 49-72 years). They presented acute coronary syndromes with 38 patients on platelet glycoprotein Ⅱb/Ⅲa receptor antagonists. All patients underwent off-pump coronary artery bypass surgery via sternotomy with the intention of complete coronary revascularization.Results An average of 2.9 grafts per patient were performed and the posterior descending artery and marginal branches of the circumflex artery were grafted in 83.3% of the patients. There were 4 events of intraoperative cardiac instability, precipitated by occlusion of right coronary artery or positioning of a cardiomegaly heart, leading to immediate conversion to CPB. The mortality rate was 3% (2/66). Two patients suffered postoperative stroke while three needed hemofiltration for acute renal failure. Post surgery elective coronary angiography (n=46) showed no significant stenosis.Conclusion Emergency off-pump coronary artery surgery with complete revascularization is feasible in patients with acute coronary syndrome with low morbidity and mortality and excellent early results.

  11. 炫速双源CT的客观测量在诊断冠状动脉支架内再狭窄中的应用%Usefulness of flash dual-source computed tomography for evaluation of coronary artery in-stent restenosis

    Institute of Scientific and Technical Information of China (English)

    章盈; 毛萍; 王欢; 杜常青; 王亚利; 汤益民; 唐礼江

    2016-01-01

    Objective To investigate the value of flash dual- source computed tomography (CT) angiography in the evaluation of coronary artery in- stent restenosis (ISR). Methods 101 patients with 167 coronary stents underwent dual- source CT angiography for re- examination. CT values of different segments of vessels with stents were measured for evaluation of ISR and compared with the results of elective coronary angiography performed during fol owing 60 days. The accuracy and cut- off value of dual- source CT in the diagnosis of ISR were calculated. Results The CT image quality of 151 stents (90.5%) was suitable for evaluation. The diameter of stent was a main factor influencing CT image quality. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of dual- source CT for the diagnosis of ISR were 83.8%, 82.8%, 77.0%, 88.2%and 83.2%, respectively. The cutoff points of a difference in CT value from aortic root to the vessel 5~10mm proximal to the stent, proximal end of the stent, in- stent lumen, distal end of the stent, and the vessel 5~10mm distal to the stent for diagnosing ISR were 7.5Hu, 16.0Hu, 42.5Hu, 47.5Hu and 56.0Hu, respectively. Conclusion The in- stent lumen of coronary artery can be imaged clearly by dual- source CT, which could provide higher diagnostic accuracy of ISR.%目的:探讨炫速双源CT在诊断冠状动脉支架内再狭窄(ISR)中的应用。方法对101例患者植入的167枚冠脉支架行炫速双源CT血管显像复查,测量支架段各部位的CT值评价支架内再狭窄,并与随后60d内所做的选择性冠状动脉造影结果对比,计算炫速双源CT诊断ISR的准确程度及诊断ISR的CT临界值。结果炫速双源CT显示151枚(90.5%)支架的影像质量适于诊断,支架直径是主要影响因素。炫速双源CT评价冠状动脉ISR的敏感度、特异度、阳性预测值、阴性预测值和符合率分别为83.8%、82.8%、77.0%、88.2%和83.2%。诊断ISR

  12. 无保护左主干病变冠状动脉搭桥术与雷帕霉素洗脱支架治疗的对比研究%Comparison between drug-eluting stents and coronary artery bypass surgery for the treatment of unprotected left main coronary artery stenosis

    Institute of Scientific and Technical Information of China (English)

    庞明杰; 张宏; 赵燕; 陶杰; 张云梅; 吴咏昕

    2012-01-01

    Objective:To evaluate the effect of coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) with drug-eluting stents (DES) for unprotected left main coronary artery disease and investigate the relevance between the risk of lesion and major adverse cardiac and cerebrovascular event (MACCE) by syntax score system. Method: We reviewed outcomes among 176 consecutive patients with unprotected left main coronary artery disease who underwent PCI or CAGB. Eighty patients underwent CABG (CABG group) and nin-ty-six patients received drug-eluting stents (PCI group). Base features, angiographic characteristics, operation data, SYNTAX SCORE and MACCE rates followed up 3 years after operation were recorded. Result:There were more target vessel revascularization events in the PCI group than in the CABG group, although MACCE and MACCE-free rates were similar at 3 years follow-up. Patients were divided into high-score group (≥30.0) and low-score group (30. 0 is the independent risk factor of the outcomes of PCI. In the high-score group, MACCE was higher and MACCE-free rate was lower at 3 years in patients underwent PCI than CABG (23. 53% vs 18. 05%, P0. 05), but MACCE-free rate was lower in patients underwent CABG than PCI at 3 years follow-up (75.00% vs 82. 14%, P<0. 05). Conclusion: PCI with DES is feasible and effective for patients with unprotected left main coronary artery disease.%目的:回顾性分析无保护左主干病变患者使用雷帕霉素洗脱支架(DES)的经皮冠状动脉介入治疗(PCI)与冠状动脉旁路移植手术(CABG)治疗的中、远期疗效,并探讨应用SYNTAX SCORE来评估病变风险与临床事件的相关性.方法:本研究回顾性收集了176例无保护左主干病变患者,其中CABG组80例,PCI-DES组96例.收集患者的基本情况、左主干病变特点及SYNTAX评分、CABG和PCI手术情况,随访患者术后3年的主要不良心脑血管事件(MACCE)的发生率.结果:术后3年随访,PCI-DES组

  13. Comparison of the sirolimus-eluting versus paclitaxel-eluting coronary stent in patients with diabetes mellitus: the diabetes and drug-eluting stent (DiabeDES) randomized angiography trial

    DEFF Research Database (Denmark)

    Maeng, Michael; Jensen, Lisette Okkels; Galloe, Anders Michael;

    2008-01-01

    The aim of the present study was to evaluate angiographic late luminal loss after the implantation of sirolimus-eluting Cypher stents and paclitaxel-eluting Taxus stents in patients with diabetes. The study was a Danish multicenter, open-label, randomized trial. One hundred fifty-three patients...... with diabetes with coronary artery disease were randomized to Cypher (n = 76) or Taxus (n = 77) stent implantation. All patients were followed for 8 months. The primary end point was 8-month angiographic in-stent late luminal loss. This primary end point was reduced in the Cypher group compared with the Taxus.......8%) in the Cypher and Taxus groups, respectively (p = 0.25). Definite stent thrombosis was observed in 2 patients (in the Taxus group), no patients had probable stent thrombosis, and 1 patient in each group had possible stent thrombosis. Major adverse cardiac events (cardiac death, myocardial infarction, definite...

  14. Protein losing enteropathy secondary to a pulmonary artery stent

    Directory of Open Access Journals (Sweden)

    Narayanswami Sreeram

    2012-01-01

    Full Text Available A 2-year-old patient with hypoplastic left heart syndrome presented 6 months following Fontan completion with protein-losing enteropathy (PLE. He had undergone stent implantation in the left pulmonary artery after the Norwood procedure, followed by redilation of the stent prior to Fontan completion. Combined bronchoscopic and catheterization studies during spontaneous breathing confirmed left bronchial stenosis behind the stent, and diastolic systemic ventricular pressure during expiration of 25 mm Hg. We postulate that the stent acts as a valve, against which the patient generates high expiratory pressures, which are reflected in the ventricular diastolic pressure. This may be the cause of PLE.

  15. Renal subcapsular haematoma: an unusual complication of renal artery stenting

    Institute of Scientific and Technical Information of China (English)

    XIA Dan; CHEN Shan-wen; ZHANG Hong-kun; WANG Shuo

    2011-01-01

    After successful renal artery angioplasty and stent placement, a patient in a fully anticoagulated state developed hypotension and flank pain. Computed tomography (CT) of the abdomen revealed a large renal subcapsular haematoma which was successfully managed conservatively without embolotherapy and surgical intervention. To prevent hemorrhage after renal artery stenting, it is necessary to underscore the importance of reducing the contrast volume and pressure of angiography, controlling systemic blood pressure, and monitoring guide wire position at all times.

  16. Acute intracerebral haemorrhage complication after carotid artery stenting

    Directory of Open Access Journals (Sweden)

    Chiriac A.

    2015-06-01

    Full Text Available Intracranial hemorrhage following carotid artery stenting is a recognized rare complication but with potentially devastating evolution. Reports of acute cerebral hemorrhage injury following internal carotid artery (ICA angioplasty are few, and usually were discussed in correlation with hyperperfusion syndrome. In this article we present a patient who experienced a fatal ipsilateral basal ganglia hemorrhage within 10 minutes after carotid angioplasty and stent placement

  17. Dobutamine Stress Cardiovascular Magnetic Resonance Imaging in Patients after Invasive Coronary Revascularization with Stent Placement

    Energy Technology Data Exchange (ETDEWEB)

    Heilmaier, C.; Meier, F.; Forsting, M.; Schlosser, T.W. (Dept. of Diagnostic and Interventional Radiology and Neuroradiology, Univ. Hospital Essen, Essen (Germany)). e-mail: christina.heilmaier@uni-due.de; Bruder, O.; Jochims, M.; Sabin, G.V. (Dept. of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany)); Barkhausen, J. (Dept. of Radiology and Nuclear Medicine, Univ. Hospital Schleswig-Holstein, Campus Luebeck, Luebeck (Germany))

    2009-12-15

    Background: High-dose dobutamine stress magnetic resonance (DSMR) is a well-established imaging technique for the detection of coronary artery disease (CAD). Purpose: To investigate the value of DSMR for the detection of in-stent restenoses (ISR) in patients with prior coronary stenting, using invasive coronary angiography (ICA) as the standard of reference. Material and Methods: 50 patients with 74 stents and without wall motion abnormalities at rest were examined on a 1.5T MR scanner and underwent ICA for clinical reasons within 14 days after DSMR examination. A dobutamine/atropine stress protocol was employed until age-predicted heart rate was achieved, and imaging was performed in at least three long- and three short-axis views using a segmented steady-state free precession sequence (repetition/echo time [TR/TE] 3/1.5 ms, flip angle 60 deg). All examinations were read by an experienced cardiologist and radiologist in consensus, with myocardial ischemia being defined as a new stress-induced wall motion abnormality in at least one myocardial segment. Statistical analysis was performed on a per-vessel (left circumflex artery [LCX], left anterior descending artery [LAD], and right coronary artery [RCA]) basis and with regard to the number of affected vessels (one-, two- or three-vessel disease). Results: ICA yielded seven ISR, of which one was missed by DSMR (sensitivity 86%, 95% confidence interval [CI] 0.42-0.99). Sixty-seven coronary arteries showed no ISR in ICA; however, due to new wall motion abnormalities, seven ISR were suspected in DSMR (2xRCA, 3xLCX, and 2xLAD; sensitivity 86%, specificity 90%, positive predictive value 46%, negative predictive value 98%, and diagnostic accuracy 89%). The per-vessel analysis of the three main coronary arteries revealed highest sensitivity (100%), specificity (93%), and diagnostic accuracy (94%) for the LAD. Conclusion: High-dose DSMR is an accurate, noninvasive technique for the detection of ISR and reliably allows

  18. Different prognosis of coronary stenting: distal left anterior descending coronary artery hemodynamics ultrasonography and analysis of clinical multi-factors%冠状动脉支架置入术后左前降支血流变化及临床因素分析

    Institute of Scientific and Technical Information of China (English)

    叶艺; 汪婧

    2013-01-01

    Objective To evaluate the value of the distal left anterior descending coronary artery (LAD) flow velocity measured by transthoracic Doppler echocardiography (TTDE) for the noninvasive assessment of the LAD stent implantation. Methods 47 cases after performing Intracoronary Stent Implantation, namely Left ventricular normal group (LVN, 35 cases), Left ventricular remodeling group (LVR,12 cases), were studied. The distal LAD flow signal was observed and the pulsed-Doppler velocity curve was recorded by TTDE. The peak diastolic flow velocity (PVd) and the peak systolic flow velocity (PVs) were measured. The diastolic systolic velocity ratio (DSVR) was calculated. Results Acute myo-cardial infarction,Killips of cardiac function >2, three or diffuse coronary artery disease, more than stent placement and length of stent longer than 20 mm with left ventricular remodeling were significantly correlated. The PVd, PVs and DSVR had no significant difference between two groups, means coronary recanalization. LVN group color display for a bright line-like, suggesting that myocardial perfusion improved survival and LVR group's dim the intermittent, prompted serious adverse myocardial reperfusion. Reverse flow suggested there was collateral circulation, except lumen Restenosis. Conclusion Monitoring of the distal LAD flow velocity by TTDE was useful in the noninvasive assessment efficacy after stent intervention for the LAD lesions.%目的 经胸冠状动脉多普勒血流显像评估左前降支(left anterier descending,LAD)支架置入术疗效的临床价值.方法 47例曾行LAD支架置入术的患者,根据是否发生左室重构分为恢复组(Left ventricular normal,LVN) 35例、左室重构组(Left ventricular remodeling,LVR) 12例,进行临床资料的相关分析.应用冠状动脉多普勒血流显像观察两组的LAD远端血流动力学变化,记录流速曲线,测定舒张期峰值流速(PVd)、收缩期峰值流速(PVs)及舒张期与收

  19. Influence of metal alloy and the profile of coronary stents in patients with multivessel coronary disease

    Directory of Open Access Journals (Sweden)

    Luciano Maurício de Abreu Filho

    2011-01-01

    Full Text Available BACKGROUND: In Brazil, despite the recommendations of the Brazilian Society of Hemodynamics and Interventional Cardiology, the National Health System has not yet approved the use of drug-eluting stents. In percutaneous coronary interventions performed in the public and part of the private health care system, bare metal stents are used as the only option. Therefore, new information on bare metal stents is of great importance. The primary endpoint was to evaluate the influence of the alloy and the profile of coronary stents on late loss and restenosis rates 6 months after implantation in patients with multivessel coronary disease. METHODS: Single center, randomized and prospective study comparison of cobalt-chromium versus stainless steel stent implantation in 187 patients with multivessel coronary disease. At least one cobalt-chromium and one stainless steel stent were implanted per patient. RESULTS: Mean age of patients was 59.5 + 10.1 years with a prevalence of males (66.3% and patients with acute coronary syndrome (56%. Baseline clinical characteristics were similar with hypertension in 146 (78%, dyslipidemia in 85 (45.5% and diabetes in 68 (36.4%. Two hundred and twenty-nine cobalt-chromium and 284 stainless steel stents were implanted. Angiographic variables showed no statistically significant difference. Angiographic follow-up to 6 months after implantation showed similar late loss and restenosis rates. CONCLUSION: The use of two different alloys, stainless steel and cobalt-chrome stents, in the same patient and in the same vessel produced similar 6-month restenosis and late loss rates.

  20. Drug-eluting stents versus bare-metal stents for acute coronary syndrome.

    Science.gov (United States)

    Feinberg, Joshua; Nielsen, Emil Eik; Greenhalgh, Janette; Hounsome, Juliet; Sethi, Naqash J; Safi, Sanam; Gluud, Christian; Jakobsen, Janus C

    2017-08-23

    Approximately 3.7 million people died from acute coronary syndrome worldwide in 2012. Acute coronary syndrome, also known as myocardial infarction or unstable angina pectoris, is caused by a sudden blockage of the blood supplied to the heart muscle. Percutaneous coronary intervention is often used for acute coronary syndrome, but previous systematic reviews on the effects of drug-eluting stents compared with bare-metal stents have shown conflicting results with regard to myocardial infarction; have not fully taken account of the risk of random and systematic errors; and have not included all relevant randomised clinical trials. To assess the benefits and harms of drug-eluting stents versus bare-metal stents in people with acute coronary syndrome. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS, SCI-EXPANDED, and BIOSIS from their inception to January 2017. We also searched two clinical trials registers, the European Medicines Agency and the US Food and Drug Administration databases, and pharmaceutical company websites. In addition, we searched the reference lists of review articles and relevant trials. Randomised clinical trials assessing the effects of drug-eluting stents versus bare-metal stents for acute coronary syndrome. We included trials irrespective of publication type, status, date, or language. We followed our published protocol and the methodological recommendations of Cochrane. Two review authors independently extracted data. We assessed the risks of systematic error by bias domains. We conducted Trial Sequential Analyses to control the risks of random errors. Our primary outcomes were all-cause mortality, major cardiovascular events, serious adverse events, and quality of life. Our secondary outcomes were angina, cardiovascular mortality, and myocardial infarction. Our primary assessment time point was at maximum follow-up. We assessed the quality of the evidence by the GRADE approach. We included 25

  1. Sensor to detect endothelialization on an active coronary stent

    Directory of Open Access Journals (Sweden)

    Coffey Arthur C

    2010-11-01

    Full Text Available Abstract Background A serious complication with drug-eluting coronary stents is late thrombosis, caused by exposed stent struts not covered by endothelial cells in the healing process. Real-time detection of this healing process could guide physicians for more individualized anti-platelet therapy. Here we present work towards developing a sensor to detect this healing process. Sensors on several stent struts could give information about the heterogeneity of healing across the stent. Methods A piezoelectric microcantilever was insulated with parylene and demonstrated as an endothelialization detector for incorporation within an active coronary stent. After initial characterization, endothelial cells were plated onto the cantilever surface. After they attached to the surface, they caused an increase in mass, and thus a decrease in the resonant frequencies of the cantilever. This shift was then detected electrically with an LCR meter. The self-sensing, self-actuating cantilever does not require an external, optical detection system, thus allowing for implanted applications. Results A cell density of 1300 cells/mm2 on the cantilever surface is detected. Conclusions We have developed a self-actuating, self-sensing device for detecting the presence of endothelial cells on a surface. The device is biocompatible and functions reliably in ionic liquids, making it appropriate for implantable applications. This sensor can be placed along the struts of a coronary stent to detect when the struts have been covered with a layer of endothelial cells and are no longer available surfaces for clot formation. Anti-platelet therapy can be adjusted in real-time with respect to a patient's level of healing and hemorrhaging risks.

  2. Primary stenting as emergency therapy in acute basilar artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Spreer, Joachim; Arnold, Sebastian; Klisch, Joachim; Schumacher, Martin [Section of Neuroradiology, University Hospital Freiburg, Breisacher Strasse 64, 79106 Freiburg (Germany); Els, Thomas; Hetzel, Andreas; Huppertz, Hans-Juergen; Oehm, Eckhardt [Department of Neurology, University Hospital Freiburg, Freiburg (Germany)

    2002-09-01

    In three patients with acute occlusion of the basilar artery intra-arterial fibrinolysis resulted in only partial recanalization and revealed severe stenosis as the underlying cause. Application of micro-stents without previous dilatation resulted in vessel re-opening. Two patients had an excellent clinical outcome. One patient died 10 days after the stroke due to brainstem infarction. Emergency primary stent application may improve the outcome in acute basilar artery occlusion, if intra-arterial thrombolysis fails to re-establish a sufficient flow. (orig.)

  3. Early results of coronary artery bypass grafting with coronary endarterectomy for severe coronary artery disease

    Directory of Open Access Journals (Sweden)

    Toischer Karl

    2009-09-01

    Full Text Available Abstract Background Despite the existence of controversial debates on the efficiency of coronary endarterectomy (CE, it is still used as an adjunct to coronary artery bypass grafting (CABG. This is particularly true in patients with endstage coronary artery disease. Given the improvements in cardiac surgery and postoperative care, as well as the rising number of elderly patient with numerous co-morbidities, re-evaluating the pros and cons of this technique is needed. Methods Patient demographic information, operative details and outcome data of 104 patients with diffuse calcified coronary artery disease were retrospectively analyzed with respect to functional capacity (NYHA, angina pectoris (CCS and mortality. Actuarial survival was reported using a Kaplan-Meyer analysis. Results Between August 2001 and March 2005, 104 patients underwent coronary artery bypass grafting (CABG with adjunctive coronary endarterectomy (CE in the Department of Thoracic-, Cardiac- and Vascular Surgery, University of Goettingen. Four patients were lost during follow-up. Data were gained from 88 male and 12 female patients; mean age was 65.5 ± 9 years. A total of 396 vessels were bypassed (4 ± 0.9 vessels per patient. In 98% left internal thoracic artery (LITA was used as arterial bypass graft and a total of 114 vessels were endarterectomized. CE was performed on right coronary artery (RCA (n = 55, on left anterior descending artery (LAD (n = 52 and circumflex artery (RCX (n = 7. Ninety-five patients suffered from 3-vessel-disease, 3 from 2-vessel- and 2 from 1-vessel-disease. Closed technique was used in 18%, open technique in 79% and in 3% a combination of both. The most frequent endarterectomized localization was right coronary artery (RCA = 55%. Despite the severity of endstage atherosclerosis, hospital mortality was only 5% (n = 5. During follow-up (24.5 ± 13.4 months, which is 96% complete (4 patients were lost caused by unknown address 8 patients died (cardiac

  4. Early results of coronary artery bypass grafting with coronary endarterectomy for severe coronary artery disease

    Science.gov (United States)

    Schmitto, Jan D; Kolat, Philipp; Ortmann, Philipp; Popov, Aron F; Coskun, Kasim O; Friedrich, Martin; Sossalla, Samuel; Toischer, Karl; Mokashi, Suyog A; Tirilomis, Theodor; Baryalei, Mersa M; Schoendube, Friedrich A

    2009-01-01

    Background Despite the existence of controversial debates on the efficiency of coronary endarterectomy (CE), it is still used as an adjunct to coronary artery bypass grafting (CABG). This is particularly true in patients with endstage coronary artery disease. Given the improvements in cardiac surgery and postoperative care, as well as the rising number of elderly patient with numerous co-morbidities, re-evaluating the pros and cons of this technique is needed. Methods Patient demographic information, operative details and outcome data of 104 patients with diffuse calcified coronary artery disease were retrospectively analyzed with respect to functional capacity (NYHA), angina pectoris (CCS) and mortality. Actuarial survival was reported using a Kaplan-Meyer analysis. Results Between August 2001 and March 2005, 104 patients underwent coronary artery bypass grafting (CABG) with adjunctive coronary endarterectomy (CE) in the Department of Thoracic-, Cardiac- and Vascular Surgery, University of Goettingen. Four patients were lost during follow-up. Data were gained from 88 male and 12 female patients; mean age was 65.5 ± 9 years. A total of 396 vessels were bypassed (4 ± 0.9 vessels per patient). In 98% left internal thoracic artery (LITA) was used as arterial bypass graft and a total of 114 vessels were endarterectomized. CE was performed on right coronary artery (RCA) (n = 55), on left anterior descending artery (LAD) (n = 52) and circumflex artery (RCX) (n = 7). Ninety-five patients suffered from 3-vessel-disease, 3 from 2-vessel- and 2 from 1-vessel-disease. Closed technique was used in 18%, open technique in 79% and in 3% a combination of both. The most frequent endarterectomized localization was right coronary artery (RCA = 55%). Despite the severity of endstage atherosclerosis, hospital mortality was only 5% (n = 5). During follow-up (24.5 ± 13.4 months), which is 96% complete (4 patients were lost caused by unknown address) 8 patients died (cardiac failure: 3

  5. Shrinking the Supply Chain for Implantable Coronary Stent Devices.

    Science.gov (United States)

    Moore, Sean S; O'Sullivan, Kevin J; Verdecchia, Francesco

    2016-02-01

    Stenting treatments for the management of disease in the heart, arterial and venous systems, biliary ducts, urethras, ureters, oesophageal tract and prostate have made enormous technical advances since their introduction into clinical use. The progression from metallic to polymer based bio-absorbable stents, coupled with the advances in additive manufacturing techniques, present a unique opportunity to completely re-envision the design, manufacture, and supply chain of stents. This paper looks at current stenting trends and proposes a future where the stent supply chain is condensed from ~150 days to ~20 min. The Cardiologist therefore has the opportunity to become a designer, manufacturer and user with patients receiving custom stents specific to their unique pathology that will be generated, delivered and deployed in the Cath-lab. The paper will outline this potentially revolutionary development and consider the technical challenges that will need to be overcome in order to achieve these ambitious goals. A high level overview of the generating eluting stents in situ program-GENESIS-is outlined including some early experimental work.

  6. Transcatheter Aortic Valve Implantation Assisted with Microcatheter: A New Method to Avoid Coronary Artery Obstruction

    Institute of Scientific and Technical Information of China (English)

    Xiang Chen; Guo-Jun Chu; Fei-Yu Wang; Yu-Feng Zhu; Ben Zhang; Xian-Xian Zhao; Yong-Wen Qin

    2015-01-01

    Background:Lack of fluoroscopic landmarks can make valve deployment more difficult in patients with absent aortic valve (AV)calcification.The goal of this article was to evaluate the feasibility and effectiveness oftranscatheter implantation of a valved stent into the AV position of a goat,assisted with a microcatheter which provides accurate positioning of coronary artery ostia to help valved stent deployment.Methods:The subjects were 10 healthy goats in this study.A microcatheter was introduced into the distal site of right coronary artery (RCA)through femoral artery sheath.A minimal thoracic surgery approach was used to access the apex of the heart.The apex of the left ventricle was punctured; a delivery catheter equipped with the valved stent was introduced over a stiffguidewire into the aorta arch.We could accurately locate the RCA ostia through the microcatheter placed in the RCA under fluoroscopy.After correct valve position was confirmed,the valved stent was implanted after rapid inflation of the balloon.The immediate outcome of the function of the valved stents was evaluated after implantation.Results:All ten devices were successfully implanted into the AV position of the goats.Immediate observation after the procedure showed that the valved stents were in the desired position after implantation by angiography,echocardiogram.No obstruction of coronary artery ostia occurred,and no moderate to severe aortic regurgitation was observed.Conclusions:When the procedure of transcatheter implantation of a balloon-expandable valved stent into the AV position of goats is assisted with microcatheter positioning coronary artery ostia,the success rate of operation can be increased in those with noncalcified AV.

  7. Disseminated Intravascular Coagulation as a Possible Cause of Acute Coronary Stent Thrombosis: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Syed Amer

    2012-01-01

    Full Text Available Disseminated intravascular coagulation (DIC, as a cause of acute coronary stent thrombosis, has not yet been reported to our knowledge. We report a case of 64-year-old male, who presented with non-ST-segment elevation myocardial infarction (NSTEMI. Coronary angiography revealed right coronary artery (RCA stenosis and a drug eluting stent was deployed. Fifteen hours following the intervention, the patient developed an inferior wall ST elevation myocardial infarction. Repeat cardiac catheterization showed an acute in-stent thrombosis. Following thrombectomy, another stent was placed. The patient noted to have an acute drop in platelet count following the second intervention. Two hours following repeat intervention, the patient again developed chest pain and EKG showed recurrent ST-segment elevations in leads II, III, and aVF. Prior to repeat cardiac catheterization, the patient became unresponsive and developed cardiogenic shock. The patient was resuscitated and intubated, and repeat catheterization showed complete stent thrombosis. Intracoronary tissue plasminogen activator (tPA was given. The platelet count further dropped. Additional studies confirmed the diagnosis of DIC. No further cardiac catheterization was done at this point. The patient then later had a cardiac arrest and unfortunately cardiopulmonary resuscitation could not revive him. Amongst the etiologies of acute stent thrombosis, DIC was deemed a possible cause.

  8. [Treatment of compression of the left main coronary artery in patients with pulmonary hypertension].

    Science.gov (United States)

    Talavera, María L; Diez, Mirta; Cáneva, Jorge O; Boughen, Roberto P; Valdivieso, León; Mendiz, Oscar

    2011-01-01

    Chest pain is a frequent symptom in patients with pulmonary hypertension of any etiology. Its pathophysiology has not been clearly established, the proposed causes are ischemia due to increased right ventricle wall stress, transient increased pulmonary hypertension resulting in acute pulmonary artery dilatation and external compression of the left main coronary artery (LMCA) by a dilated pulmonary artery. We report and discuss here three cases where the association between chest pain and compression of the LMCA by a dilated pulmonary artery could be shown, and they were treated with coronary stenting.

  9. The efficacy of the drug-eluting stents in the treatment of coronary artery disease in patients with diabetes%药物洗脱支架置入对糖尿病并发冠心病患者不良心血管事件的影响

    Institute of Scientific and Technical Information of China (English)

    黄冰清; 钱菊英

    2009-01-01

    Objective To evaluate the efficacy of the drug-eluting stents in the treatment of coronary artery diseases in patients with diabetes. Methods This study included a retrospective database of 600 consecutive patients with coronary artery disease who underwent drug-eluting stems implantation in Zhong Shan Hospital,including 147 pa-tients with diabetes. The MACE in this study included death of any cause,nonfatal myocardial infarction,target lesion revascularization and target vessel revascularization. All the MACE were recorded. The efficacy of the drug-eluting stents was evaluated by the incidence of MACE and the rate of in-stent restenosis. Results No significant differences were found concerning the incidence of MACE (7. 9% vs 4. 9% ,P = 0. 344) as well as the rate of ISR(6. 0% vs 4.9% ,P =0. 540) between patients with diabetes and patients without diabetes. No significant differences were found concerning the incidence of MACE(7.9% vs 4. 9% ,P = 0. 344) as well as the rate of ISR( 1.4% vs 1.9% ,P = 1. 000) between Cypher stents and TAXUS stents. Conclusion Drug-eluting stents are effective in the treatment of coronary artery disease of patients with diabetes. There was no significant difference in the rate of MACE and in-stent restenosis between the two leading drug-eluting stents of sirolimus eluting Cypher stent and the paclitaxle eluting TAX-US stent.%目的 评价药物洗脱支架置入对糖尿病并发冠心病患者不良事件的影响.方法 对600例行药物洗脱支架植入术的患者进行随访,其中糖尿病患者147例.通过随访术后主要不良心血管事件(包括死亡,非致死性心肌梗死,再次靶病变血运重建和再次靶血管血运重建)和支架内再狭窄的发生率评价药物洗脱支架在糖尿病患者中的疗效.结果 糖尿病患者和非糖尿病患者术后的主要不良心血管事件(7.9%与4.9%,P=0.344)和支架内再狭窄(6.0%与4.9%,P=0.540)发生率之间差异无统计学意义.糖尿病患者植

  10. Does the quantitative assessment of coronary artery dimensions predict the physiologic significance of a coronary stenosis?

    NARCIS (Netherlands)

    F. Zijlstra (Felix); J.C.W. van Ommeren (Jan-Kees); J.H.C. Reiber (Johan); P.W.J.C. Serruys (Patrick)

    1987-01-01

    textabstractTo study the relationship between the quantitatively assessed coronary artery dimensions and the regional coronary flow reserve as measured by digital subtraction cineangiography, we investigated 17 coronary arteries with a single discrete proximal stenosis and 12 normal coronary

  11. Acute and long-term outcome after Palmaz-Schatz stenting: analysis from the New Approaches to Coronary Intervention (NACI) registry.

    Science.gov (United States)

    Carrozza, J P; Schatz, R A; George, C J; Leon, M B; King, S B; Hirshfeld, J W; Curry, R C; Ivanhoe, R J; Buchbinder, M; Cleman, M W; Goldberg, S; Ricci, D; Popma, J J; Safian, R D; Baim, D S

    1997-11-20

    The randomized Stent Restenosis Study (STRESS) and Belgium Netherlands Stent (Benestent) trials established that elective use of Palmaz-Schatz stents (PSSs) in native coronary arteries with de novo lesions is associated with increased procedural success and reduced restenosis. However there are other clinical indications for which stents are commonly used (unplanned use, vein grafts, restenosis lesions) that are not addressed in these studies. From 1990-1992, 688 lesions in 628 patients were treated with PSSs in the New Approaches to Coronary Intervention (NACI) registry. Angiographic core laboratory readings were available for 543 patients (595 lesions, of which 106 were stented for unplanned indications, 239 were in saphenous vein bypass grafts, and 296 were previously treated). The cohort of patients in whom stents were placed for unplanned indications had more women, current smokers, and had a higher incidence of recent myocardial infarction (MI). Patients who underwent stenting of saphenous vein grafts were older, had a higher incidence of diabetes mellitus, unstable angina, prior MI, and congestive heart failure. Lesion success was similar in all cohorts (98%), but procedural success was significantly higher for planned stenting (96% vs 87%; p < 0.01). Predictors of adverse events in-hospital were presence of a significant left main stenosis and stenting for unplanned indication. The incidence of target lesion revascularization by 30 days was significantly higher for patients undergoing unplanned stenting due to a higher risk for stent thrombosis. Recent MI, stenting in native lesion, and small postprocedural minimum lumen diameter independently predicted target lesion revascularization at 30 days. Independent predictors of death, Q-wave myocardial infarction, or target lesion revascularization at 1 year included severe concomitant disease, high risk for surgery, left main disease, stenting in the left main coronary artery, and low postprocedure minimum lumen

  12. Multimodality imaging of coronary artery bypass grafts

    NARCIS (Netherlands)

    Salm, Liesbeth Pauline

    2006-01-01

    This thesis describes multiple imaging modalities to examine coronary artery bypass grafts, and the research which was performed to further develop noninvasive imaging techniques to detect stenoses in native coronary arteries and bypass grafts in patients who experienced recurrent chest pain after

  13. Multimodality imaging of coronary artery bypass grafts

    NARCIS (Netherlands)

    Salm, Liesbeth Pauline

    2006-01-01

    This thesis describes multiple imaging modalities to examine coronary artery bypass grafts, and the research which was performed to further develop noninvasive imaging techniques to detect stenoses in native coronary arteries and bypass grafts in patients who experienced recurrent chest pain after c

  14. Coronary artery calcium score: current status

    Science.gov (United States)

    Neves, Priscilla Ornellas; Andrade, Joalbo; Monção, Henry

    2017-01-01

    The coronary artery calcium score plays an Important role In cardiovascular risk stratification, showing a significant association with the medium- or long-term occurrence of major cardiovascular events. Here, we discuss the following: protocols for the acquisition and quantification of the coronary artery calcium score by multidetector computed tomography; the role of the coronary artery calcium score in coronary risk stratification and its comparison with other clinical scores; its indications, interpretation, and prognosis in asymptomatic patients; and its use in patients who are symptomatic or have diabetes. PMID:28670030

  15. Picosecond laser micromachining of nitinol and platinum-iridium alloy for coronary stent applications

    Energy Technology Data Exchange (ETDEWEB)

    Muhammad, N.; Whitehead, D.; Li, L. [University of Manchester, Laser Processing Research Centre, School of Mechanical, Aerospace and Civil Engineering, Manchester (United Kingdom); Boor, A.; Oppenlander, W. [Swiss Tec AG, Schaan, Principality of Liechtenstein (Liechtenstein); Liu, Z. [University of Manchester, Corrosion and Protection Centre, School of Materials, Manchester (United Kingdom)

    2012-03-15

    The demand for micromachining of coronary stents by means of industrial lasers rises quickly for treating coronary artery diseases, which cause more than one million deaths each year. The most widely used types of laser for stent manufacturing are Nd:YAG laser systems with a wavelength of 1064 nm with pulse lengths of 10{sup -3}-10{sup -2} seconds. Considerable post-processing is required to remove heat-affected zones (HAZ), and to improve surface finishes and geometry. Using a third harmonic laser radiation of picosecond laser (6 x 10{sup -12} s pulse duration) in UV range, the capability of the picosecond laser micromachining of nitinol and platinum-iridium alloy for coronary stent applications are presented. In this study dross-free cut of nitinol and platinum-iridium alloy tubes are demonstrated and topography analysis of the cut surface is carried out. The HAZ characteristics have been investigated by means of microscopic examinations and measurement of micro-hardness distribution near the cut zones. (orig.)

  16. Picosecond laser micromachining of nitinol and platinum-iridium alloy for coronary stent applications

    Science.gov (United States)

    Muhammad, N.; Whitehead, D.; Boor, A.; Oppenlander, W.; Liu, Z.; Li, L.

    2012-03-01

    The demand for micromachining of coronary stents by means of industrial lasers rises quickly for treating coronary artery diseases, which cause more than one million deaths each year. The most widely used types of laser for stent manufacturing are Nd:YAG laser systems with a wavelength of 1064 nm with pulse lengths of 10-3-10-2 seconds. Considerable post-processing is required to remove heat-affected zones (HAZ), and to improve surface finishes and geometry. Using a third harmonic laser radiation of picosecond laser (6×10-12 s pulse duration) in UV range, the capability of the picosecond laser micromachining of nitinol and platinum-iridium alloy for coronary stent applications are presented. In this study dross-free cut of nitinol and platinum-iridium alloy tubes are demonstrated and topography analysis of the cut surface is carried out. The HAZ characteristics have been investigated by means of microscopic examinations and measurement of micro-hardness distribution near the cut zones.

  17. The Clinicaal and Angiograghic Outcome of 290 Cases after Stent Placement in Small Coronary Vessels

    Institute of Scientific and Technical Information of China (English)

    郭文怡; 贾国良; 李伟杰; 秦涛; 李成祥; 栾荣华; 吕安林; 王小燕; 李媛

    2003-01-01

    Objectives To invest the success procedure,immediate outcome after procedure,the rate of main adverse cardiac events after procedure and restenosis after stent placement in small coronary vessels. Methods 290 patients with selected or emergency stent implantation in small vessels from April, 1997 to March, 2002. Total 299 vessels, 304 lesions and 316 stents were statisted. The successs rate of procedure, immediate outcome after procedure, the rate of main adverse cardiac events after procedure and restenosis after stent placement in small coronary vessels were assessed. The patients were followed up l month to 4 years. Re-catheter angiography were done in 122/290 patients. Results The narrow rate of lesion dropped from 89% ± 12% before procedure to 5% ±5% after procedure (diameter). 202 patients were followed up 1 month(69.7% ). 197/202 cases were survival. 5/202 cases died in 3hrs to 7days. 2/5 cases died of persistent hypotension after procedure. 1/5 case died of acute left heart failure. 2/5 cases died of sudden death. 180 cases were followed up 5 months to 4 years. The non-event survival (NES) rate was 73.3% (132/180). The re-angiography were done in 122 cases. Restenosis happened in 39 cases (30.3%). 37 patients repeated PCI. 2 patients went to CABG. 2 cases got angina recurrence and were proved second time restenosis by re-angiography. The third time PCI was done in 1 patient. The other patients went to CABG. 1 case died of chronic heart failure after 2 years. 1 case suffered acute myocardial infarction on artery stent implanted. Conclusions There are high success rate of procedure and perfect immediate outcome in stent placement in small vessels.Main adverse cardiac events did not increased. Non-event survial was satisfied in long term follow - up.Restenosis rate was showed slightly higher than the one of main vessels.

  18. Metabolic syndrome and coronary artery disease in Ossabaw compared with Yucatan swine.

    Science.gov (United States)

    Neeb, Zachary P; Edwards, Jason M; Alloosh, Mouhamad; Long, Xin; Mokelke, Eric A; Sturek, Michael

    2010-08-01

    Metabolic syndrome (MetS), a compilation of associated risk factors, increases the risk of type 2 diabetes and coronary artery disease (CAD, atherosclerosis), which can progress to the point of artery occlusion. Stents are the primary interventional treatment for occlusive CAD, and patients with MetS and hyperinsulinemia have increased restenosis. Because of its thrifty genotype, the Ossabaw pig is a model of MetS. We tested the hypothesis that, when fed high-fat diet, Ossabaw swine develop more features of MetS, greater native CAD, and greater stent-induced CAD than do Yucatan swine. Animals of each breed were divided randomly into 2 groups and fed 2 different calorie-matched diets for 40 wk: control diet (C) and high-fat, high-cholesterol atherogenic diet (H). A bare metal stent was placed in the circumflex artery, and pigs were allowed to recover for 3 wk. Characteristics of MetS, macrovascular and microvascular CAD, in-stent stenosis, and Ca(2+) signaling in coronary smooth muscle cells were evaluated. MetS characteristics including, obesity, glucose intolerance, hyperinsulinemia, and elevated arterial pressure were elevated in Ossabaw swine compared to Yucatan swine. Ossabaw swine with MetS had more extensive and diffuse native CAD and in-stent stenosis and impaired coronary blood flow regulation compared with Yucatan. In-stent atherosclerotic lesions in Ossabaw coronary arteries were less fibrous and more cellular. Coronary smooth muscle cells from Ossabaw had impaired Ca(2+) efflux and intracellular sequestration versus cells from Yucatan swine. Therefore, Ossabaw swine are a superior model of MetS, subsequent CAD, and cellular Ca(2+) signaling defects, whereas Yucatan swine are leaner and relatively resistant to MetS and CAD.

  19. Spontaneous Coronary Artery Dissection with Cardiac Tamponade.

    Science.gov (United States)

    Goh, Anne C H; Lundstrom, Robert J

    2015-10-01

    Spontaneous coronary artery dissection is a rare cause of acute coronary syndrome. Clinical presentation ranges from chest pain alone to ST-segment-elevation myocardial infarction, ventricular fibrillation, and sudden death. The treatment of patients with spontaneous coronary artery dissection is challenging because the disease pathophysiology is unclear, optimal treatment is unknown, and short- and long-term prognostic data are minimal. We report the case of a 70-year-old woman who presented with an acute ST-segment-elevation myocardial infarction secondary to a spontaneous dissection of the left anterior descending coronary artery. She was treated conservatively. Cardiac tamponade developed 16 hours after presentation. Repeat coronary angiography revealed extension of the dissection. Medical therapy was continued after the hemopericardium was aspirated. The patient remained asymptomatic 3 years after hospital discharge. To our knowledge, this is the first reported case of spontaneous coronary artery dissection in association with cardiac tamponade that was treated conservatively and had a successful outcome.

  20. Polymer-free versus permanent polymer drug eluting stents in coronary artery disease: A meta-analysis of 10 RCTs with 6575 patients

    Institute of Scientific and Technical Information of China (English)

    De-Wei Wu; Meng-Yue Yu; Hai-Yang Gao; Li Zhang; Fei Song; Xin-Yue Zhang; Yong-Jian Wu

    2015-01-01

    Background:Permanent polymer drug eluting stents (PP-DES) may induce inflammation of the vessel wall due to the existence of the polymer,which may delay intimal healing.Polymer-free DES (PF-DES) that eliminate the polymeric carrier may potentially lead to safer DES.However,the safety and efficacy of PF-DES remains controversial.Methods:Randomized controlled trials comparing PF-DES with PP-DES were searched in online database including MEDLINE,Excerpta Medica Database (EMBASE) and Cochrane Library.Studies reporting late lumen loss (LLL),all-cause death,myocardial infarction (MI),target lesion revascularization (TLR) and late stent thrombosis (LST) were enrolled and quantitatively analyzed.Results:Ten studies enrolling 6575 patients were included in this meta-analysis.The PF-DES showed a benefit in reducing all-cause death (OR =0.77,95% CI:0.61 to 0.98,P =0.03) and long-term LLL (weighted mean difference (WMD)-0.16 mm,95% CI:-0.22 to -0.11 mm,P < 0.001),while no superiority was found in reducing short-term LLL (WMD 0.03 mm,95% CI:-0.07-0.13 mm,P =0.57),MI (OR =1.12,95% CI:0.19 to 23.18,P=0.39),TLR (OR =1.19,95% CI:0.42 to 3.38,P=0.83)and LST (OR =0.92,95%CI:0.05 to 5.71,P =0.74).Conclusion:PF-DES showed benefits in reducing long-term LLL and mortality compared with PP-DES,but no superiority was found in short-term LLL,MI,TLR and LST.These findings provide a sound basis for the wide application of PF-DES in the future.

  1. Single Coronary Artery with Anomalous Origin of the Right Coronary Artery from the Distal Portion of Left Circumflex Artery: A Very Rare Case

    Directory of Open Access Journals (Sweden)

    MohammadReza Pourbehi

    2015-10-01

    Full Text Available Congenital anomalies of coronary arteries, albeit rare, may be significant contributors to angina pectoris, hemodynamic abnormalities, and sudden cardiac death. A 47-year-old man referred to us with atypical chest pain. Electrocardiography demonstrated no significant ischemic changes, but cardiac troponin I test was positive. The patient underwent coronary angiography, which revealed a single coronary artery from the left Valsalva sinus. In addition, the left anterior descending (LAD and the left circumflex (LCx arteries were in normal position with significant stenosis in the mid-portion of the LAD and the distal portion of the LCx. A large branch originated from the distal portion of the LCx and tapered toward the proximal portion as the right coronary artery (RCA. This is a rare coronary anomaly that has no ischemic result. Coronary lesions were the cause of the patient’s angina pectoris. Angioplasty and stenting of the LAD and LCx was done, and medical therapy (Clopidogrel, Aspirin, Atorvastatin, and Metoprolol was continued. The patient was asymptomatic at 8 months’ follow-up.

  2. Coronary artery anomalies in Turner Syndrome

    DEFF Research Database (Denmark)

    Viuff, Mette H; Trolle, Christian; Wen, Jan;

    2016-01-01

    BACKGROUND: Congenital heart disease, primarily involving the left-sided structures, is often seen in patients with Turner Syndrome. Moreover, a few case reports have indicated that coronary anomalies may be more prevalent in Turner Syndrome than in the normal population. We therefore set out...... to systematically investigate coronary arterial anatomy by computed tomographic coronary angiography (coronary CTA) in Turner Syndrome patients. METHODS: Fifty consecutive women with Turner Syndrome (mean age 47 years [17-71]) underwent coronary CTA. Patients were compared with 25 gender-matched controls. RESULTS......: Coronary anomaly was more frequent in patients with Turner Syndrome than in healthy controls [20% vs. 4% (p = 0.043)]. Nine out of ten abnormal cases had an anomalous left coronary artery anatomy (absent left main trunk, n = 7; circumflex artery originating from the right aortic sinus, n = 2). One case had...

  3. Choice PTTM guidewire for recanalization of total occlusive coronary arteries

    Institute of Scientific and Technical Information of China (English)

    OUYANG Ping; HE Shi-hua; CHEN Wei-Kang; WOO Carrie

    2002-01-01

    Objective: To evaluate the therapeutic effects of 0. 014″Choice PTTM wire in chronic total occlusion angioplasty. Methods: Balloon angioplasty was attempted in 25 arteries with chronic total occlusion,with the mean time of occlusion of 17±13 months (ranging from 2 to 84 months) and mean length of 14±6mm (ranging from 5 to 25 mm). The morphology of the lesions included bridging collaterals (4 cases), calcification (3 cases) and major side branch at the lesion (4 cases) . Choice PTTM wire was used electively in all the cases. Results: Lesion was crossed successfully in 92% (23/25) cases, without incidences of dissection of the coronary artery with subintimal entry. Balloon angioplasy and stenting (n=21) were performed with good immediate angiograghic results. Acute myocardial infarction or death occurred in none of the patients.Conclusion Successful recanalization of chronic coronary total occlusions using Choice PTTM wire can be achieved with good safety.

  4. [Surgical treatment of a patient with coronary artery disease combined with stenosis of the left subclavian artery].

    Science.gov (United States)

    Sevastyanov, A V; Chernyavsky, A M; Chernyavsky, M A; Edemsky, A G; Nesmachnyi, A S; Tarkova, A R

    2016-01-01

    Presented in the article is a clinical case report regarding successfully used hybrid technology in combined lesions of the coronary arteries and the first segment of the left subclavian artery. The patient was subjected to simultaneous hybrid operation, i. e., transaortic angioplasty with stenting of the left subclavian artery by means of the Assurant stent accompanied by coronary artery bypass grafting. The early postoperative period turned out uneventful. The patient was discharged with no complications and in a satisfactory condition. At the 12-month follow-up visit, the patient presented no complaints, felling satisfactory as he stated, and there was no evidence of restenosis as revealed by the findings of ultrasonographic examination. This clinical case report demonstrates that in this type of combined lesion the use of hybrid technologies makes it possible to obtain a favourable surgical outcome both in the immediate and remote postoperative periods.

  5. Influence of local peroxisome proliferator-activated receptor gamma (PPARγ) activation of restenosis/in-stent restenosis following experimental coronary intervention in the porcine stent model

    OpenAIRE

    Klinowski, Jens

    2011-01-01

    Background: Coronary heart disease (CHD) remains the main cause of mortality in the industrial countries. In approximately 80% of all coronary interventions, coronary stents are inserted. Bare metal stents (BMS) show a restenosis rate of around 10 – 30%, and with drug eluting stents (DES) the restenosis rate drops to 5 – 10%. Coronary restenosis following percutaneous coronary intervention (PCI) represents a serious problem, both clinically and economically. Patients with Diabetes mellitus...

  6. Spontaneous Coronary Artery Dissection: Case Report Review of the Literature

    Directory of Open Access Journals (Sweden)

    Kemal Karaağaç

    2013-03-01

    Full Text Available Spontaneous coronary artery dissection is a rare cause of acute coronary syndrome with a high risk of mortality. The clinical presentation is similar to the atherosclerotic coronary artery disease. The diagnosis is usually made by coronary angiography. Spontaneous coronary artery dissection is more common in women than men. Fast and accurate diagnosis and treatment of spontaneous coronary artery dissection patients improves survival. Therapeutic options include surgery, percutaneous coronary intervention and medical therapy.

  7. Comparison of short-term outcomes after carotid artery stenting according to different stent designs

    Science.gov (United States)

    Açar, Göksel; Özkan, Birol; Alıcı, Gökhan; Yazıcıoglu, Mehmet Vefik; Bulut, Mustafa; Kalkan, Mehmet Emin; Demir, Serdar; Acar, Rezzan Deniz; Boztosun, Bilal

    2013-01-01

    Introduction In the developed countries, stroke is the third most common cause of death. There are many data indicating that stents reduce the risk of embolism but there are few publications assessing whether different stent designs can influence the periprocedural complications. Aim To determine the effects of open- and closed-cell stent designs on 1-month results of carotid artery stenting (CAS). Material and methods The study group consisted of 290 consecutive patients (216 men and 74 women, mean age 66.6 ±8.7 years). Neuroprotection with a distal protection device was used in all cases. The patients were divided into two groups: the open-cell stent group (n = 144) and the closed-cell stent group (n = 138). Major adverse cardiac and cerebrovascular events (MACCE) described as myocardial infarction, stroke and death within 1 month were recorded and analysed subsequently. Periprocedural hypotension and transient cerebral ischaemia at 1 month after the CAS procedure were also assessed. Results We treated 290 carotid stenoses and stents were implanted in all patients. Fifteen patients (5.5%) were treated by staged CAS due to bilateral carotid artery disease. The technical success rate was 97.2%. There was no difference in the MACCE and transient cerebral ischaemia rate at 1 month between the two groups (p = 0.44 and p = 0.94, respectively). The incidence of ischaemic stroke was lower in the closed-cell stent group (2.77% vs. 0%; p = 0.04). The periprocedural rate of hypotension was higher in the closed-cell stent group (2.1% vs. 7.2%; p = 0.04). Conclusions Closed-cell stents are associated with a low rate of ischaemic stroke. We think that closed-cell stents may be preferred in patients at high risk of embolism. PMID:24570703

  8. Coronary artery anatomy of the goat.

    Science.gov (United States)

    Lipovetsky, G; Fenoglio, J J; Gieger, M; Srinivasan, M R; Dobelle, W H

    1983-05-01

    The coronary arteries of the goat heart were studied using angiographic techniques and molds of the coronary vessel trees. Blood supplies to the left and right ventricles, interventricular septum, atrioventricular node, and apex of the caprine heart were studied. The goat possesses a left dominant pattern of coronary supply with relatively uniform coronary anatomy and may provide a good large animal model for testing cardiovascular assist devices.

  9. Segmented Coronary Artery Aneurysms and Kawasaki Disease

    Directory of Open Access Journals (Sweden)

    Hamid Reza Ghaemi

    2011-05-01

    Full Text Available Kawasaki disease (KD is an acute vasculitis syndrome of unknown etiology. It occurs in infants and young children,affecting mainly small and medium-sized arteries, particularly the coronary arteries. Generalized microvasculitis occurs in the first 10 days, and the inflammation persists in the walls of medium and small arteries, especially the coronary arteries, and changes to coronary artery aneurysms.We report the case of a 10-month-old girl referred to our center three months after the onset of disease due to the aneurysmsof the coronary arteries. During the acute phase of her illness, she received 2 gr/kg intravenous gamma globulin; and afterher referral to us, the patient was treated by antiaggregant doses of acetylsalicylic acid (ASA (5 mg/kg and Warfarin (1 mg/daily. At three months’ follow-up, the aneurysms still persisted in the echocardiogram.

  10. The influence of stent material on coronary stent CTA%支架材质对冠状动脉支架CTA成像影响

    Institute of Scientific and Technical Information of China (English)

    刘健萍; 高明勇; 刘辉; 刘再毅; 梁长虹

    2016-01-01

    目的:分析支架材质对冠状动脉支架CTA成像的影响。方法回顾性分析60例冠状动脉支架CTA资料。以不同材质把支架分组并与金标准冠状动脉造影对照,评价不同材质支架组间CTA图像质量并比较组间CTA诊断冠状动脉支架再狭窄的准确性。结果60例患者共置入95个支架,包含13种不同支架厂商产品,两种支架材质,分别是钴铬合金支架(22个)和不锈钢支架(73个)。钴铬合金支架较不锈钢支架伪影少,可评价率(86.7% vs 77.5%, P =0.002)、诊断准确性高(94.7%vs 71.2%, P =0.034)。结论钴铬合金支架较不锈钢支架伪影少,可评价率高,诊断准确性高,有利于冠脉支架CTA评价,值得推荐厂家采用的较理想的支架材质。不锈钢价值伪影相对较多,冠脉支架CTA评价准确率相对较低,值得引起临床及厂家的注意。%Objective To evaluate the influence of stent material on the coronary angiography with 64-MSCT.Methods Cor-onary artery CTA images of 60 patients with coronary artery implanted stents were retrospectively analyzed.Stents of sixty patients were grouped into cobalt-chromium alloy group and stainless steel group based on stent material.We intended to investigate the in-fluence of stent material on the CTA and the diagnostic accuracy of CTA in detecting prominent ISR, as referring to Coronary ar-giography.Results Ninety-five stents, including 13 types of stents, were implanted in 60 patients.The accuracy, sensitivity, specificity, positive predictive, negative predictive and Kappa value for CTA diagnosis of prominent ISR were 74.3%, 81.4%, 76.5%, 79.5%and 0.558 respectively.In comparison to stainless steel stents, cobalt-chromium alloy stents seens less artifacts, and the rate of available evaluation (86.7%vs 77.5%, P =0.002) and the accuracy of diagnosis (94.7% vs 71.2%, P =0.034) were bigger.Conclusion As compared with stainless steel

  11. Cell Area and Strut Distribution Changes of Bent Coronary Stents: A Finite Element Analysis

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yang; WU Wei; YANG Da-zhi; QI Min

    2009-01-01

    Coronary stents are metal coils or mesh tubes delivered to blocked vessels through catheters, which are expanded by balloons to reopen and scaffold target vessels. Recently,special drugs are carried by stents (drug-eluting stents) to further reduce in-stent restenosis rate after stenting procedure. However,continual study on biomechanical characteristics of stents is necessary for better interactions between stents and tissue, or to provide a more suitable drug loading platform for drug-eluting stents. The purpose of this paper is to show how finite element methods can be used to study cell area and strut distribution changes of bent coronary stents. A same bending deformation was applied to two commercial coronary stent models by a rigid curved vessel. Results show that the stent design influenced the changes of cell area and strut distribution under bending situation. The stent with links had more cell area changes at outer curvature, and the stent with peak-peak (><) strut design could have strut contact and overlapping at inner curvature. In conclusion, this finite element method can be used to study and compare cell area and strut distribution changes of bent stents,and to provide a convenient tool for designers in testing and improving biomechanical characteristics of new stents.

  12. Prognostic implications of coronary artery calcium in the absence of coronary artery luminal narrowing

    NARCIS (Netherlands)

    I. Cho (Iksung); Ó Hartaigh, B. (Bríain); H. Gransar (Heidi); V. Valenti (Valentina); F.Y. Lin (Fay); S. Achenbach (Stephan); D.S. Berman (Daniel); M.J. Budoff (Matthew); T.Q. Callister (Tracy); M. Al-Mallah (Mouaz); F. Cademartiri (Filippo); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); A.M. Dunning (Alison); A. Delago (Augustin); T.C. Villines (Todd); M. Hadamitzky (Martin); J. Hausleiter (Jörg); J. Leipsic (Jonathon); L.J. Shaw (Leslee); P.A. Kaufmann (Philipp); R.C. Cury (Ricardo); G.M. Feuchtner (Gudrun); Y.-J. Kim (Yong-Jin); E. Maffei (Erica); G.L. Raff (Gilbert); G. Pontone (Gianluca); D. Andreini (Daniele); H.-J. Chang (Hyuk-Jae); J.K. Min (James)

    2017-01-01

    textabstractBackground and aims: Coronary artery calcium (CAC) scoring is a predictor of future adverse cl