  1. Chemical treatment of slime in industrial cooling water systems

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Noriyuki

    1987-07-01

    Chemical suppression test was made for slime produced in pipes of the industrial water cooling systems. The 3 month chemical slime treatment test in 1984 proved to be effective, and the test has been carried out since July, 1985. The objective was to suppress the generation of slime by decreasing the number of general bacteria by slime treatment agent (fungicide of chloride group). The number of bacteria in the supplied water was compared for the time and day of the week when samples were collected. It was found that there was no regular rule in the variation of the number of bacteria, with measured result of 30-10/sup 6/ variation range. From the variation in the number of bacteria and the sticking conditions of slime on the test board, it became clear that suppression was possible by drastically decreasing the bacteria number in cooling water in the early stage of chemical supply, followed by resupply of treatment agent in a week when the bacteria would be restored to its original amount by supplied water. However, the method is to suppress the slime generation, and is unable to stop the generation completely. (9 figs, 3 tabs)

  2. 40 CFR 749.68 - Hexavalent chromium-based water treatment chemicals in cooling systems.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Hexavalent chromium-based water treatment chemicals in cooling systems. 749.68 Section 749.68 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT WATER TREATMENT CHEMICALS Air Conditioning and Cooling Systems § 749.68 Hexavalent...

  3. Environmental compatible cooling water treatment chemicals; Umweltvertraegliche Chemikalien in der Kuehlwasserkonditionierung

    Energy Technology Data Exchange (ETDEWEB)

    Gartiser, S.; Urich, E.

    2002-02-01

    In Germany about 32 billion m{sup 3}/a cooling water are discharged from industrial plants and power industry. These are conditioned partly with biocides, scaling and corrosion inhibitors. Within the research project the significance of cooling water chemicals was evaluated, identifying the chemicals from product information, calculating their loads from consumption data of more than 180 cooling plants and investigating the basic data needed for an environmental hazard assessment. Additionally the effects of cooling water samples and products were determined in biological test systems. Batch tests were performed under defined conditions in order to measure the inactivation of cooling water biocides. (orig.)

  4. Use of Treated Municipal Wastewater as Power Plant Cooling System Makeup Water: Tertiary Treatment versus Expanded Chemical Regimen for Recirculating Water Quality Management

    Energy Technology Data Exchange (ETDEWEB)

    David Dzombak; Radisav Vidic; Amy Landis

    2012-06-30

    Treated municipal wastewater is a common, widely available alternative source of cooling water for thermoelectric power plants across the U.S. However, the biodegradable organic matter, ammonia-nitrogen, carbonate and phosphates in the treated wastewater pose challenges with respect to enhanced biofouling, corrosion, and scaling, respectively. The overall objective of this study was to evaluate the benefits and life cycle costs of implementing tertiary treatment of secondary treated municipal wastewater prior to use in recirculating cooling systems. The study comprised bench- and pilot-scale experimental studies with three different tertiary treated municipal wastewaters, and life cycle costing and environmental analyses of various tertiary treatment schemes. Sustainability factors and metrics for reuse of treated wastewater in power plant cooling systems were also evaluated. The three tertiary treated wastewaters studied were: secondary treated municipal wastewater subjected to acid addition for pH control (MWW_pH); secondary treated municipal wastewater subjected to nitrification and sand filtration (MWW_NF); and secondary treated municipal wastewater subjected nitrification, sand filtration, and GAC adsorption (MWW_NFG). Tertiary treatment was determined to be essential to achieve appropriate corrosion, scaling, and biofouling control for use of secondary treated municipal wastewater in power plant cooling systems. The ability to control scaling, in particular, was found to be significantly enhanced with tertiary treated wastewater compared to secondary treated wastewater. MWW_pH treated water (adjustment to pH 7.8) was effective in reducing scale formation, but increased corrosion and the amount of biocide required to achieve appropriate biofouling control. Corrosion could be adequately controlled with tolytriazole addition (4-5 ppm TTA), however, which was the case for all of the tertiary treated waters. For MWW_NF treated water, the removal of ammonia by

  5. Use of Treated Municipal Wastewater as Power Plant Cooling System Makeup Water: Tertiary Treatment versus Expanded Chemical Regimen for Recirculating Water Quality Management

    Energy Technology Data Exchange (ETDEWEB)

    David Dzombak; Radisav Vidic; Amy Landis

    2012-06-30

    Treated municipal wastewater is a common, widely available alternative source of cooling water for thermoelectric power plants across the U.S. However, the biodegradable organic matter, ammonia-nitrogen, carbonate and phosphates in the treated wastewater pose challenges with respect to enhanced biofouling, corrosion, and scaling, respectively. The overall objective of this study was to evaluate the benefits and life cycle costs of implementing tertiary treatment of secondary treated municipal wastewater prior to use in recirculating cooling systems. The study comprised bench- and pilot-scale experimental studies with three different tertiary treated municipal wastewaters, and life cycle costing and environmental analyses of various tertiary treatment schemes. Sustainability factors and metrics for reuse of treated wastewater in power plant cooling systems were also evaluated. The three tertiary treated wastewaters studied were: secondary treated municipal wastewater subjected to acid addition for pH control (MWW_pH); secondary treated municipal wastewater subjected to nitrification and sand filtration (MWW_NF); and secondary treated municipal wastewater subjected nitrification, sand filtration, and GAC adsorption (MWW_NFG). Tertiary treatment was determined to be essential to achieve appropriate corrosion, scaling, and biofouling control for use of secondary treated municipal wastewater in power plant cooling systems. The ability to control scaling, in particular, was found to be significantly enhanced with tertiary treated wastewater compared to secondary treated wastewater. MWW_pH treated water (adjustment to pH 7.8) was effective in reducing scale formation, but increased corrosion and the amount of biocide required to achieve appropriate biofouling control. Corrosion could be adequately controlled with tolytriazole addition (4-5 ppm TTA), however, which was the case for all of the tertiary treated waters. For MWW_NF treated water, the removal of ammonia by

  6. [Immediate cooling with water: emergency treatment of burns].

    Science.gov (United States)

    Latarjet, J

    1990-01-01

    Experimental data have demonstrated that prolonged immediate cooling with cold water is the best first-aid treatment for burn injuries. However in France, this treatment is rarely applied; instead old, inefficient and aggravating methods are still very popular. Pediatricians must help to change this practice by recommending immediate cold water treatment for burns in children.

  7. Advances in alkaline cooling water treatment technology: An update

    Energy Technology Data Exchange (ETDEWEB)

    Shaffer, A.E. Jr.; Klatskin, S.D.

    1985-01-01

    A series of chromate and non-chromate treatment programs, specifically designed for alkaline pH cooling waters, have been developed. The treatments provide excellent corrosion and scale control over a broad range of water chemistries and are applicable to high conductivity and iron contaminated waters. Low levels of zinc are used to reduce the dependency on alkalinity, chromate and calcium carbonate supersaturation for corrosion control. The precipitation and fouling problems previously encountered with zinc containing treatments have been eliminated by the use of polymeric dispersants.

  8. POOL WATER TREATMENT AND COOLING SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    V. King

    2000-06-19

    The Pool Water Treatment and Cooling System is located in the Waste Handling Building (WHB), and is comprised of various process subsystems designed to support waste handling operations. This system maintains the pool water temperature within an acceptable range, maintains water quality standards that support remote underwater operations and prevent corrosion, detects leakage from the pool liner, provides the capability to remove debris from the pool, controls the pool water level, and helps limit radiological exposure to personnel. The pool structure and liner, pool lighting, and the fuel staging racks in the pool are not within the scope of the Pool Water Treatment and Cooling System. Pool water temperature control is accomplished by circulating the pool water through heat exchangers. Adequate circulation and mixing of the pool water is provided to prevent localized thermal hotspots in the pool. Treatment of the pool water is accomplished by a water treatment system that circulates the pool water through filters, and ion exchange units. These water treatment units remove radioactive and non-radioactive particulate and dissolved solids from the water, thereby providing the water clarity needed to conduct waste handling operations. The system also controls pool water chemistry to prevent advanced corrosion of the pool liner, pool components, and fuel assemblies. Removal of radioactivity from the pool water contributes to the project ALARA (as low as is reasonably achievable) goals. A leak detection system is provided to detect and alarm leaks through the pool liner. The pool level control system monitors the water level to ensure that the minimum water level required for adequate radiological shielding is maintained. Through interface with a demineralized water system, adequate makeup is provided to compensate for loss of water inventory through evaporation and waste handling operations. Interface with the Site Radiological Monitoring System provides continuous

  9. Study on chemical control indicators for circulating cooling systems water chemistry at power plants

    OpenAIRE

    Кишневский, Виктор Афанасьевич; Чиченин, Вадим Валентинович

    2014-01-01

    An analysis of applied stability indices, used for water chemistry control of circulating cooling systems at TPP and NPP is given in the paper.The spectrum of controlled indicators of circulating and make-up water during long-term operation of various water chemistries on scale models of circulating cooling systems at TPP and NPP is investigated.The results of chemical control of water chemistry with dosing mineral acid to make-up water and acrylic water chemistry without dosing mineral acid ...

  10. Ozone Treatment For Cooling Towers

    Science.gov (United States)

    Blackwelder, Rick; Baldwin, Leroy V.; Feeney, Ellen S.

    1990-01-01

    Report presents results of study of cooling tower in which water treated with ozone instead of usual chemical agents. Bacteria and scale reduced without pollution and at low cost. Operating and maintenance costs with treatment about 30 percent of those of treatment by other chemicals. Corrosion rates no greater than with other chemicals. Advantage of ozone, even though poisonous, quickly detected by smell in very low concentrations.

  11. Desinfection of cooling towers and cooling water by UV-treatment on the example of a chemical company; Desinfektion von Kuehltuermen und Kuehlkreislaeufen durch UV-Behandlung am Beispiel eines Chemiebetriebs

    Energy Technology Data Exchange (ETDEWEB)

    Peuters, J.; Carbone, J. [Sadepan Chimica NV (Belgium); Daele, D. van (DVD Technology); Dams, S.; Weckenmann, J.; Soerensen, M. [a.c.k. aqua concept GmbH, Karlsruhe (Germany)

    2007-07-01

    Using a Belgian adhesives manufacturer as example, it is shown how formation and growth of micro-organisms can adversely affect a modern manufacturing process. The problem lies not with the actual process solution, but in the cooling section. Installation of a suitably-configured UV reactor allowed long-term operation without any problems from micro-organisms. The outcome was a much more stable process at acceptable cost and with significantly lower volumes of solid waste. (orig.)

  12. Automatic devices for electrochemical water treatment with cooling of electrolyte

    Directory of Open Access Journals (Sweden)

    Trišović Tomislav Lj.

    2016-01-01

    Full Text Available The most common disinfectants for water treatment are based on chlorine and its compounds. Practically, water treatments with chlorine compounds have no alternative, since they provide, in comparison to other effective processes such as ozonization or ultraviolet irradiation, high residual disinfection capacity. Unfortunately, all of chlorine-based compounds for disinfection tend to degrade during storage, thus reducing the concentration of active chlorine. Apart from degradation, additional problems are transportation, storage and handling of such hazardous compounds. Nowadays, a lot of attention is paid to the development of electrochemical devices for in situ production of chlorine dioxide or sodium hypochlorite as efficient disinfectants for water treatment. The most important part of such a device is the electrochemical reactor. Electrochemical reactor uses external source of direct current in order to produce disinfectants in electrochemical reactions occurring at the electrodes. Construction of an electrochemical device for water treatment is based on evaluation of optimal conditions for electrochemical reactions during continues production of disinfectants. The aim of this study was to develop a low-cost electrochemical device for the production of disinfectant, active chlorine, at the place of its usage, based on newly developed technical solutions and newest commercial components. The projected electrochemical device was constructed and mounted, and its operation was investigated. Investigations involved both functionality of individual components and device in general. The major goal of these investigations was to achieve maximal efficiency in extreme condition of elevated room temperature and humidity with a novel device construction involving coaxial heat exchanger at the solution inlet. Room operation of the proposed device was investigated when relative humidity was set to 90% and the ambient temperature of 38°C. The obtained

  13. Cooling water treatment - Processes and regulations; Kuehlwasserbehandlung - Verfahren und Vorschriften

    Energy Technology Data Exchange (ETDEWEB)

    Kirsten, J. [Aquatech GmbH, Nieder-Olm (Germany)

    1998-09-01

    Determination of optimal water treatment methods is to be based on requirements set by technical specifications, economic efficiency aspects, and legal regulations. It is an important task and should be done by experts in cooperation with the responsible supervisory bodies. (orig./CB) [Deutsch] Zusammenfassend kann gesagt werden, dass bei der Auswahl des optimalen Verfahrens einer Kuehlwasserbehandlung technische Anforderungen, wirtschaftliche Vorgaben und behoerdliche Auflagen gleichermassen beruecksichtigt werden muessen. Diese Aufgabe sollte von Fachleuten wahrgenommen und mit den zustaendigen Behoerden abgestimmt werden. (orig.)

  14. Treatment Process Requirements for Waters Containing Hydraulic Fracturing Chemicals

    Science.gov (United States)

    Stringfellow, W. T.; Camarillo, M. K.; Domen, J. K.; Sandelin, W.; Varadharajan, C.; Cooley, H.; Jordan, P. D.; Heberger, M. G.; Reagan, M. T.; Houseworth, J. E.; Birkholzer, J. T.

    2015-12-01

    A wide variety of chemical additives are used as part of the hydraulic fracturing (HyF) process. There is concern that HyF chemicals will be released into the environment and contaminate drinking water, agricultural water, or other water used for beneficial purposes. There is also interest in using produced water (water extracted from the subsurface during oil and gas production) for irrigation and other beneficial purposes, especially in the arid Southwest US. Reuse of produced water is not speculative: produced water can be low in salts and is being used in California for irrigation after minimal treatment. In this study, we identified chemicals that are used for hydraulic fracturing in California and conducted an analysis to determine if those chemicals would be removed by a variety of technically available treatment processes, including oil/water separation, air stripping, a variety of sorption media, advanced oxidation, biological treatment, and a variety of membrane treatment systems. The approach taken was to establish major physiochemical properties for individual chemicals (log Koc, Henry's constant, biodegradability, etc.), group chemicals by function (e.g corrosion inhibition, biocides), and use those properties to predict the fate of chemical additives in a treatment process. Results from this analysis is interpreted in the context of what is known about existing systems for the treatment of produced water before beneficial reuse, which includes a range of treatment systems from oil/water separators (the most common treatment) to sophisticated treatment trains used for purifying produced water for groundwater recharge. The results show that most HyF chemical additives will not be removed in existing treatment systems, but that more sophisticated treatment trains can be designed to remove additives before beneficial reuse.

  15. Review on Chemical treatment of Industrial Waste Water | Sahu ...

    African Journals Online (AJOL)

    Review on Chemical treatment of Industrial Waste Water. ... used and lot of wastewater generated from industries due their processes and washing purpose. A large number of chemicals are used for the production of potable water and ... powdered activated carbon (PAC) can remove taste and odour compounds and micro ...

  16. Introducing Water-Treatment Subjects into Chemical Engineering Education.

    Science.gov (United States)

    Caceres, L.; And Others

    1992-01-01

    Proposes that inclusion of waste water treatment subjects within the chemical engineering curriculum can provide students with direct access to environmental issues from both a biotechnological and an ethical perspective. The descriptive details of water recycling at a copper plant and waste water stabilization ponds exemplify this approach from…

  17. Advances in chemical technologies for water and wastewater treatment: preface

    Institute of Scientific and Technical Information of China (English)

    Xiaochang WANG

    2009-01-01

    @@ Chemical technologies have been applied for water and wastewater treatment since more than 150 year ago, and are still playing the leading role in this field. With the fast development of sciences and technologies especially in the last two decades, chemical technologies which are applicable for solving water quality and water environmental problems underwent a great development not only in traditional areas such as coagulation, solid/liquid separation, oxidation, adsorption etc., but also in the emerging multidisciplinary fields. Nowadays, an increasing number of chemists and chemical engineers has broadened research interests. Biochemical/biological technologies, ecological technologies and process modeling and simulation have become important branches of chemical technologies. Such a tendency has been well reflected in the activities of the Group of Chemists for Water and Wastewater Treatment (GCWWT), a subdivision of Chinese Chemical Society (CCS).

  18. Application of a water cooling treatment and its effect on coal-based reduction of high-chromium vanadium and titanium iron ore

    Science.gov (United States)

    Yang, Song-tao; Zhou, Mi; Jiang, Tao; Guan, Shan-fei; Zhang, Wei-jun; Xue, Xiang-xin

    2016-12-01

    A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio ( η), S removal ratio ( R S), and P removal ratio ( R P) were studied and analyzed on the basis of chemical composition determined via inductively coupled plasma optical emission spectroscopy. The metallic iron particle size and the element distribution of Fe, V, Cr, and Ti in a reduced briquette after water cooling treatment at 1350°C were determined and observed via scanning electron microscopy. The results show that the water cooling treatment improved the η, R S, and R P in the coal-based reduction of V-Ti-Cr iron ore compared to those obtained with a furnace cooling treatment. Meanwhile, the particle size of metallic iron obtained via the water cooling treatment was smaller than that of metallic iron obtained via the furnace cooling treatment; however, the particle size reached 70 μm at 1350°C, which is substantially larger than the minimum particle size required (20 μm) for magnetic separation. Therefore, the water cooling treatment described in this work is a good method for improving the quality of metallic iron in coal-based reduction and it could be applied in the coal-based reduction of V-Ti-Cr iron ore followed by magnetic separation.

  19. Application of a water cooling treatment and its effect on coal-based reduction of high-chromium vanadium and titanium iron ore

    Institute of Scientific and Technical Information of China (English)

    Song-tao Yang; Mi Zhou; Tao Jiang; Shan-fei Guan; Wei-jun Zhang; and Xiang-xin Xue

    2016-01-01

    A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V–Ti–Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), S removal ratio (RS), and P removal ratio (RP) were studied and analyzed on the basis of chemical composition determined via inductively coupled plasma optical emission spectroscopy. The metallic iron particle size and the element distribution of Fe, V, Cr, and Ti in a reduced briquette after water cooling treatment at 1350°C were determined and observed via scanning electron microscopy. The results show that the water cooling treatment improved theη,RS, and RP in the coal-based reduction of V–Ti–Cr iron ore compared to those obtained with a furnace cooling treatment. Meanwhile, the particle size of metallic iron obtained via the water cooling treatment was smaller than that of metallic iron obtained via the furnace cooling treatment; however, the particle size reached 70μm at 1350°C, which is substantially larger than the minimum particle size required (20μm) for mag-netic separation. Therefore, the water cooling treatment described in this work is a good method for improving the quality of metallic iron in coal-based reduction and it could be applied in the coal-based reduction of V–Ti–Cr iron ore followed by magnetic separation.

  20. Comparison of laboratory and field observations: Ozone water treatment for cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, K.P. [Marley Cooling Tower Co., Mission, KS (United States)

    1996-11-01

    This evaluation, comparing laboratory- and field-generated data, explains the functional results of ozone water treatment use for operating heating, ventilating, and air-conditioning (HVAC) cooling water systems. These effects are classified in the areas of biological growth control, corrosion rate control, and scale control or retardation. Limitations on the application of ozone are discussed. Field results from multiple sites are examined and compared to laboratory-generated data. Theories as to mechanisms are discussed based on the accumulated information. Specific situations such as under-ozonation, and soft and hard water are discussed.

  1. A Comparative Analysis of Three Water Treatment Programs for Cooling Tower Systems

    Science.gov (United States)

    1991-09-01

    Gallic Acid Powder (item 2063) METHOD: It is necessary to follow the instructions furnished with the conductivity meter that is being used . The...the location and costs of AFLC towers. 2 Definition of Terms Terms commonly used in cooling tower water treatment. Acid : A substance that dissolves...the sulfuric acid program. This program is still indorsed by Air Force Regulation 91-40. System operators use sulfuric acid to lower the pH and

  2. Desalting a process cooling water using nanofiltration

    NARCIS (Netherlands)

    Radier, R.G.J.; van Oers, C.W.; Steenbergen, A.; Wessling, Matthias

    2001-01-01

    The cooling water system of a chemical plant of Akzo Nobel is a partly open system. The site is located at the North Sea. The air in contact with the cooling water contains seawater droplets dissolving and increasing the chloride concentration. The cooling water contains chromate to protect the inst

  3. Physical-chemical evaluation of hydraulic fracturing chemicals in the context of produced water treatment.

    Science.gov (United States)

    Camarillo, Mary Kay; Domen, Jeremy K; Stringfellow, William T

    2016-12-01

    Produced water is a significant waste stream that can be treated and reused; however, the removal of production chemicals-such as those added in hydraulic fracturing-must be addressed. One motivation for treating and reusing produced water is that current disposal methods-typically consisting of deep well injection and percolation in infiltration pits-are being limited. Furthermore, oil and gas production often occurs in arid regions where there is demand for new water sources. In this paper, hydraulic fracturing chemical additive data from California are used as a case study where physical-chemical and biodegradation data are summarized and used to screen for appropriate produced water treatment technologies. The data indicate that hydraulic fracturing chemicals are largely treatable; however, data are missing for 24 of the 193 chemical additives identified. More than one-third of organic chemicals have data indicating biodegradability, suggesting biological treatment would be effective. Adsorption-based methods and partitioning of chemicals into oil for subsequent separation is expected to be effective for approximately one-third of chemicals. Volatilization-based treatment methods (e.g. air stripping) will only be effective for approximately 10% of chemicals. Reverse osmosis is a good catch-all with over 70% of organic chemicals expected to be removed efficiently. Other technologies such as electrocoagulation and advanced oxidation are promising but lack demonstration. Chemicals of most concern due to prevalence, toxicity, and lack of data include propargyl alcohol, 2-mercaptoethyl alcohol, tetrakis hydroxymethyl-phosphonium sulfate, thioglycolic acid, 2-bromo-3-nitrilopropionamide, formaldehyde polymers, polymers of acrylic acid, quaternary ammonium compounds, and surfactants (e.g. ethoxylated alcohols). Future studies should examine the fate of hydraulic fracturing chemicals in produced water treatment trains to demonstrate removal and clarify interactions

  4. Demonstration of Noncorrosive, Capacitance- Based Water-Treatment Technology for Chilled-Water Cooling Systems

    Science.gov (United States)

    2014-09-01

    Beitelman 2009), HQUSACE published interim implementation guidance in Engineering and Construction Bulletin ECB 2012-10, Non-Chemical Treatment of...incorporation into UFGS 23 25 00. The suggested imple- mentation language includes a designer’s note based on text from ECB 2012-10, plus new language

  5. Amorphous silica scale in cooling waters

    Energy Technology Data Exchange (ETDEWEB)

    Midkiff, W.S.; Foyt, H.P.

    1976-01-01

    In 1968, most of the evaporation cooled recirculating water systems at Los Alamos Scientific Laboratory were nearly inoperable due to scale. These systems, consisting of cooling towers, evaporative water coolers, evaporative condensers, and air washers had been operated on continuous blowdown without chemical treatment. The feedwater contained 80 mg/l silica. A successful program of routine chemical addition in the make-up water was begun. Blends of chelants, dispersants and corrosion inhibitors were found to gradually remove old scale, prevent new scale, and keep corrosion to less than an indicated rate of one mil per year. An explanation has been proposed that amorphous silica by itself does not form a troublesome scale. When combined with a crystal matrix such as calcite, the resultant silica containing scale can be quite troublesome. Rapid buildup of silica containing scale can be controlled and prevented by preventing formation of crystals from other constituents in the water such as hardness or iron. (auth)

  6. Nonhazardous Chemical Treatments and Smart Monitoring and Control System for Heating and Cooling Systems

    Science.gov (United States)

    2007-06-01

    application of treatments is often inconsistent because treatment lev- els are monitored by manual chemical analysis. When treatment levels drop below lower...corrosion data. These methods of develop- ing corrosion information complement each other, and each method has advantages ; overall correlation of the...RLUs (Relative Light Units) that have been correlated to bacte- ria colony-forming units. There is also a second ATP test for sessile bacteria (surface

  7. Water-cooled electronics

    CERN Document Server

    Dumont, G; Righini, B

    2000-01-01

    LHC experiments demand on cooling of electronic instrumentation will be extremely high. A large number of racks will be located in underground caverns and counting rooms, where cooling by conventional climatisation would be prohibitively expensive. A series of tests on the direct water cooling of VMEbus units and of their standard power supplies is reported. A maximum dissipation of 60 W for each module and more than 1000 W delivered by the power supply to the crate have been reached. These values comply with the VMEbus specifications. (3 refs).

  8. Human health effects of residual carbon nanotubes and traditional water treatment chemicals in drinking water.

    Science.gov (United States)

    Simate, Geoffrey S; Iyuke, Sunny E; Ndlovu, Sehliselo; Heydenrych, Mike; Walubita, Lubinda F

    2012-02-01

    The volume of industrial and domestic wastewater is increasing significantly year by year with the change in the lifestyle based on mass consumption and mass disposal brought about by the dramatic development of economies and industries. Therefore, effective advanced wastewater treatment is required because wastewater contains a variety of constituents such as particles, organic materials, and emulsion depending on the resource. However, residual chemicals that remain during the treatment of wastewaters form a variety of known and unknown by-products through reactions between the chemicals and some pollutants. Chronic exposure to these by-products or residual chemicals through the ingestion of drinking water, inhalation and dermal contact during regular indoor activities (e.g., showering, bathing, cooking) may pose cancer and non-cancer risks to human health. For example, residual aluminium salts in treated water may cause Alzheimer's disease (AD). As for carbon nanotubes (CNTs), despite their potential impacts on human health and the environment having been receiving more and more attention in the recent past, existing information on the toxicity of CNTs in drinking water is limited with many open questions. Furthermore, though general topics on the human health impacts of traditional water treatment chemicals have been studied, no comparative analysis has been done. Therefore, a qualitative comparison of the human health effects of both residual CNTs and traditional water treatment chemicals is given in this paper. In addition, it is also important to cover and compare the human health effects of CNTs to those of traditional water treatment chemicals together in one review because they are both used for water treatment and purification. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Water Cooled Mirror Design

    Energy Technology Data Exchange (ETDEWEB)

    Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Holloway, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pulliam, Elias Noel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-03-30

    This design is intended to replace the current mirror setup being used for the NorthStar Moly 99 project in order to monitor the target coupon. The existing setup has limited movement for camera alignment and is difficult to align properly. This proposed conceptual design for a water cooled mirror will allow for greater thermal transfer between the mirror and the water block. It will also improve positioning of the mirror by using flexible vacuum hosing and a ball head joint capable of a wide range of motion. Incorporating this design into the target monitoring system will provide more efficient cooling of the mirror which will improve the amount of diffraction caused by the heating of the mirror. The process of aligning the mirror for accurate position will be greatly improved by increasing the range of motion by offering six degrees of freedom.

  10. Proposal for the award of an industrial support contract for cooling water treatment

    CERN Document Server

    1999-01-01

    This document concerns the award of an Industrial Support contract for cooling water treatment for LEP, PS and SPS. Following a market survey carried out among 46 firms in twelve Member States, a call for tenders (IT-2557/ST) was sent on 26 July 1999 to seven firms and two consortia in five Member States. By the closing date, CERN had received five tenders from firms and consortia in three Member States. The Finance Committee is invited to agree to the negotiation of a contract with the consortium AQUAZUR (FR) and SCHILLING CHEMIE (DE), the lowest bidder after realignment, for an initial period of three years, starting on 1 January 2000, for a total amount not exceeding 976 482 Swiss francs, not subject to revision until 31 December 2001. The contract will include options for two further one-year extensions beyond the initial three year period. The consortium has indicated the following distribution by country of the work covered by this adjudication proposal: FR - 52% and DE - 48%.

  11. Storing carbon dioxide in saline formations : analyzing extracted water treatment and use for power plant cooling.

    Energy Technology Data Exchange (ETDEWEB)

    Dwyer, Brian P.; Heath, Jason E.; Borns, David James; Dewers, Thomas A.; Kobos, Peter Holmes; Roach, Jesse D.; McNemar, Andrea; Krumhansl, James Lee; Klise, Geoffrey T.

    2010-10-01

    In an effort to address the potential to scale up of carbon dioxide (CO{sub 2}) capture and sequestration in the United States saline formations, an assessment model is being developed using a national database and modeling tool. This tool builds upon the existing NatCarb database as well as supplemental geological information to address scale up potential for carbon dioxide storage within these formations. The focus of the assessment model is to specifically address the question, 'Where are opportunities to couple CO{sub 2} storage and extracted water use for existing and expanding power plants, and what are the economic impacts of these systems relative to traditional power systems?' Initial findings indicate that approximately less than 20% of all the existing complete saline formation well data points meet the working criteria for combined CO{sub 2} storage and extracted water treatment systems. The initial results of the analysis indicate that less than 20% of all the existing complete saline formation well data may meet the working depth, salinity and formation intersecting criteria. These results were taken from examining updated NatCarb data. This finding, while just an initial result, suggests that the combined use of saline formations for CO{sub 2} storage and extracted water use may be limited by the selection criteria chosen. A second preliminary finding of the analysis suggests that some of the necessary data required for this analysis is not present in all of the NatCarb records. This type of analysis represents the beginning of the larger, in depth study for all existing coal and natural gas power plants and saline formations in the U.S. for the purpose of potential CO{sub 2} storage and water reuse for supplemental cooling. Additionally, this allows for potential policy insight when understanding the difficult nature of combined potential institutional (regulatory) and physical (engineered geological sequestration and extracted water

  12. Physical chemical properties of sludges of a chemical treatment of boilers feed water and ways of their utilization

    Directory of Open Access Journals (Sweden)

    T. Krasnenko

    2013-03-01

    Full Text Available Water is a necessary process for TPP power plant operation. To the power station, in the production of electricity and heat as a result of the preparation of large amounts of water to compensate for losses associated with the release of process steam for production, produce large quantities of waste water treatment - water treatment chemical sludge (WTCS.

  13. Cooling clothing utilizing water evaporation

    DEFF Research Database (Denmark)

    Sakoi, Tomonori; Tominaga, Naoto; Melikov, Arsen Krikor

    2014-01-01

    We developed cooling clothing that utilizes water evaporation to cool the human body and has a mechanism to control the cooling intensity. Clean water was supplied to the outer surface of the T-shirt of the cooling clothing, and a small fan was used to enhance evaporation on this outer surface...... temperature ranging from 27.4 to 30.7 °C to establish a suitable water supply control method. A water supply control method that prevents water accumulation in the T-shirt and water dribbling was validated; this method is established based on the concept of the water evaporation capacity under the applied...

  14. Water and chemical savings in cooling towers by using membrane capacitive deionization

    NARCIS (Netherlands)

    Limpt, van B.; Wal, van der A.

    2014-01-01

    Membrane capacitive deionization (MCDI) is a water desalination technology based on applying a voltage difference between two oppositely placed porous carbon electrodes. In front of each electrode, an ion exchange membrane is positioned, and between them, a spacer is situated, which transports the w

  15. Biofouling Control in Cooling Water

    Directory of Open Access Journals (Sweden)

    T. Reg Bott

    2009-01-01

    Full Text Available An important aspect of environmental engineering is the control of greenhouse gas emissions. Fossil fuel-fired power stations, for instance, represent a substantial contribution to this problem. Unless suitable steps are taken the accumulation of microbial deposits (biofouling on the cooling water side of the steam condensers can reduce their efficiency and in consequence, the overall efficiency of power production, with an attendant increase in fuel consumption and hence CO2 production. Biofouling control, therefore, is extremely important and can be exercised by chemical or physical techniques or a combination of both. The paper gives some examples of the effectiveness of different approaches to biofouling control.

  16. Application of MF,Ozone and RO in Treatment of Municipal Sewage Reused as Circulating Cooling Water

    Institute of Scientific and Technical Information of China (English)

    Zhang Liqiang

    2007-01-01

    @@ Reuse of treated municipal sewage as circulating cooling water of fossil-fired power plants is a very theme worthy to be studied and spread because of the water shortage in most areas of China. This paper presents a process using coagulation + MF + ozone + partial RO to deal with the recycled sewage after treated preliminarily in sewage treatment plant. The process solves effectively the problem of higher TDS and higher total hardness in product water in winter, thus is especially fit for cities where sewage quality changes obviously with seasons.

  17. Chemical drinking water quality in Ghana: water costs and scope for advanced treatment.

    Science.gov (United States)

    Rossiter, Helfrid M A; Owusu, Peter A; Awuah, Esi; Macdonald, Alan M; Schäfer, Andrea I

    2010-05-01

    To reduce child mortality and improve health in Ghana boreholes and wells are being installed across the country by the private sector, NGO's and the Ghanaian government. Water quality is not generally monitored once a water source has been improved. Water supplies were sampled across Ghana from mostly boreholes, wells and rivers as well as some piped water from the different regions and analysed for the chemical quality. Chemical water quality was found to exceed the WHO guidelines in 38% of samples, while pH varied from 3.7 to 8.9. Excess levels of nitrate (NO(3)(-)) were found in 21% of the samples, manganese (Mn) and fluoride (F(-)) in 11% and 6.7%, respectively. Heavy metals such as lead (Pb), arsenic (As) and uranium (U) were localised to mining areas. Elements without health based guideline values such as aluminium (Al, 95%) and chloride (Cl, 5.7%) were found above the provisional guideline value. Economic information was gathered to identify water costs and ability to pay. Capital costs of wells and boreholes are about pound1200 and pound3800 respectively. The majority of installation costs are generally paid by the government or NGO's, while the maintenance is expected to be covered by the community. At least 58% of the communities had a water payment system in place, either an annual fee/one-off fee or "pay-as-you-fetch". The annual fee was between pound0.3-21, while the boreholes had a water collection fee of pound0.07-0.7/m(3), many wells were free. Interestingly, the most expensive water ( pound2.9-3.5/m(3)) was brought by truck. Many groundwater sources were not used due to poor chemical water quality. Considering the cost of unsuccessful borehole development, the potential for integrating suitable water treatment into the capital and maintenance costs of water sources is discussed. Additionally, many sources were not in use due to lack of water capacity, equipment malfunction or lack of economic resources to repair and maintain equipment. Those

  18. Cooling water systems design using process integration

    CSIR Research Space (South Africa)

    Gololo, KV

    2010-09-01

    Full Text Available Cooling water systems are generally designed with a set of heat exchangers arranged in parallel. This arrangement results in higher cooling water flowrate and low cooling water return temperature thus reducing cooling tower efficiency. Previous...

  19. A Synergistic Combination of Advanced Separation and Chemical Scale Inhibitor Technologies for Efficient Use of Imparied Water As Cooling Water in Coal-based Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Jasbir Gill

    2010-08-30

    /silicate are two common potential cycle-limiting minerals for using impaired waters. For produced waters, barium sulfate and calcium sulfate are two additional potential cycle-limiting minerals. For reclaimed municipal wastewater effluents, calcium phosphate scaling can be an issue, especially in the co-presence of high silica. Computational assessment, using a vast amount of Nalco's field data from coal fired power plants, showed that the limited use and reuse of impaired waters is due to the formation of deposit caused by the presence of iron, high hardness, high silica and high alkalinity in the water. Appropriate and cost-effective inhibitors were identified and developed - LL99B0 for calcite and gypsum inhibition and TX-15060 for silica inhibition. Nalco's existing dispersants HSP-1 and HSP-2 has excellent efficacy for dispersing Fe and Mn. ED and EDI were bench-scale tested by the CRADA partner Argonne National Laboratory for hardness, alkalinity and silica removal from synthetic make-up water and then cycled cooling water. Both systems showed low power consumption and 98-99% salt removal, however, the EDI system required 25-30% less power for silica removal. For Phase 2, the EDI system's performance was optimized and the length of time between clean-in-place (CIP) increased by varying the wafer composition and membrane configuration. The enhanced EDI system could remove 88% of the hardness and 99% of the alkalinity with a processing flux of 19.2 gal/hr/m{sup 2} and a power consumption of 0.54 kWh/100 gal water. Bench tests to screen alternative silica/silicate scale inhibitor chemistries have begun. The silica/silicate control approaches using chemical inhibitors include inhibition of silicic acid polymerization and dispersion of silica/silicate crystals. Tests were conducted with an initial silica concentration of 290-300 mg/L as SiO{sub 2} at pH 7 and room temperature. A proprietary new chemistry was found to be promising, compared with a current

  20. Water treatments in semi-closed cooling circuits and their impact on the quality of effluents discharged by CERN

    CERN Document Server

    Santos Leite Cima Gomes, J; Kleiner, S

    2008-01-01

    The main goal of this study is to assess the impact of the discharges of the semi-closed water cooling circuits of CERN (European Center for Nuclear Research) on the overall quality of CERN's effluents, taking as guidelines the international legislation supported on the knowledge of the water systems of CERN. In order to reach this goal, a thorough analysis of the functioning of the semi-closed water cooling systems of CERN's particle accelerators was done, as well as, an analysis of the treatment that is done to prevent the proliferation of bacteria such as Legionella. The products used in these water treatments, as well as their impact, were also researched. In addition, a study of the applicable regulation to CERN's effluent was done. This study considered not only the regulation of France and Switzerland (CERN's host states) but also the international regulation from the European community, Portugal Germany, Spain, U.S. and Canada, having in view a better understanding of the limit values of the parameter...

  1. Expanding the potential for saline formations : modeling carbon dioxide storage, water extraction and treatment for power plant cooling.

    Energy Technology Data Exchange (ETDEWEB)

    2011-04-01

    The National Water, Energy and Carbon Sequestration simulation model (WECSsim) is being developed to address the question, 'Where in the current and future U.S. fossil fuel based electricity generation fleet are there opportunities to couple CO{sub 2} storage and extracted water use, and what are the economic and water demand-related impacts of these systems compared to traditional power systems?' The WECSsim collaborative team initially applied this framework to a test case region in the San Juan Basin, New Mexico. Recently, the model has been expanded to incorporate the lower 48 states of the U.S. Significant effort has been spent characterizing locations throughout the U.S. where CO{sub 2} might be stored in saline formations including substantial data collection and analysis efforts to supplement the incomplete brine data offered in the NatCarb database. WECSsim calculates costs associated with CO{sub 2} capture and storage (CCS) for the power plant to saline formation combinations including parasitic energy costs of CO{sub 2} capture, CO{sub 2} pipelines, water treatment options, and the net benefit of water treatment for power plant cooling. Currently, the model can identify the least-cost deep saline formation CO{sub 2} storage option for any current or proposed coal or natural gas-fired power plant in the lower 48 states. Initial results suggest that additional, cumulative water withdrawals resulting from national scale CCS may range from 676 million gallons per day (MGD) to 30,155 MGD depending on the makeup power and cooling technologies being utilized. These demands represent 0.20% to 8.7% of the U.S. total fresh water withdrawals in the year 2000, respectively. These regional and ultimately nation-wide, bottom-up scenarios coupling power plants and saline formations throughout the U.S. can be used to support state or national energy development plans and strategies.

  2. Enhanced Biocide Treatments with D-amino Acid Mixtures against a Biofilm Consortium from a Water Cooling Tower

    Directory of Open Access Journals (Sweden)

    Ru Jia

    2017-08-01

    Full Text Available Different species of microbes form mixed-culture biofilms in cooling water systems. They cause microbiologically influenced corrosion (MIC and biofouling, leading to increased operational and maintenance costs. In this work, two D-amino acid mixtures were found to enhance two non-oxidizing biocides [tetrakis hydroxymethyl phosphonium sulfate (THPS and NALCO 7330 (isothiazoline derivatives] and one oxidizing biocide [bleach (NaClO] against a biofilm consortium from a water cooling tower in lab tests. Fifty ppm (w/w of an equimass mixture of D-methionine, D-leucine, D-tyrosine, D-tryptophan, D-serine, D-threonine, D-phenylalanine, and D-valine (D8 enhanced 15 ppm THPS and 15 ppm NALCO 7330 with similar efficacies achieved by the 30 ppm THPS alone treatment and the 30 ppm NALCO 7330 alone treatment, respectively in the single-batch 3-h biofilm removal test. A sequential treatment method was used to enhance bleach because D-amino acids react with bleach. After a 4-h biofilm removal test, the sequential treatment of 5 ppm bleach followed by 50 ppm D8 achieved extra 1-log reduction in sessile cell counts of acid producing bacteria, sulfate reducing bacteria, and general heterotrophic bacteria compared with the 5 ppm bleach alone treatment. The 10 ppm bleach alone treatment showed a similar efficacy with the sequential treatment of 5 ppm bleach followed by 50 ppm D8. The efficacy of D8 was found better than that of D4 (an equimass mixture of D-methionine, D-leucine, D-tyrosine, and D-tryptophan in the enhancement of the three individual biocides against the biofilm consortium.

  3. Process integration: Cooling water systems design

    CSIR Research Space (South Africa)

    Gololo, KV

    2010-10-01

    Full Text Available This paper presents a technique for grassroot design of cooling water system for wastewater minimization which incorporates the performances of the cooling towers involved. The study focuses mainly on cooling systems consisting of multiple cooling...

  4. Effects of biocidal treatments to inhibit the growth of legionellae and other microorganisms in cooling towers.

    Science.gov (United States)

    Yamamoto, H; Ezaki, T; Ikedo, M; Yabuuchi, E

    1991-01-01

    The effects of biocidal treatments for cooling towers were examined through the use of chemicals and ultraviolet irradiation to inhibit the growth of legionellae and other microorganisms. In the water of cooling towers without continuous biocidal treatments, heterotrophic bacteria and bacterivorous protozoan first appeared, and then legionellae increased up to 10(4) CFU/100 ml. When a UV sterilizer was connected to the cooling tower, the legionellae count was 1/10 or 1/100 of that in the nontreated tower water. In the water of towers supplemented continuously with the biocidal chemicals, legionellae were not found during a 4-month period. The biocidal treatments tested were proved to suppress the increase of legionellae in cooling-tower water, and thus are useful in preventing the outbreak of legionellosis due to inhalation of contaminated aerosol from the cooling tower system.

  5. Swimming Pool Water Treatment Chemicals and/or Processes. Standard No. 22.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    Chemicals or processes used or intended for use, in the treatment of swimming pool water are covered. Minimum public health limits or acceptability in regard to toxicity, biocidal effectiveness, and chemical behavior and analysis are presented. The appendices give guidelines to the scientific and statistically sound evaluations to determine the…

  6. The Discussion about Closed Circulating Cooling Water System in Coal Chemical Industry%煤化工项目中闭式循环水系统探讨

    Institute of Scientific and Technical Information of China (English)

    安显威

    2015-01-01

    The characteristic of closed circulating cooling water system and the water-saving reason of closed cooling water were discussed. The process of closed cooling water system and some problem for closed cooling water system were introduced.%探讨了煤化工项目中循环水系统的特点和闭式冷却塔的节水原因,介绍了闭式循环水系统的流程及闭式循环水系统中可能面临的一些问题。

  7. Evaluation of physical-chemical and biological treatment of shale oil retort water

    Energy Technology Data Exchange (ETDEWEB)

    Mercer, B.W.; Mason, M.J.; Spencer, R.R.; Wong, A.L.; Wakamiya, W.

    1982-09-01

    Bench scale studies were conducted to evaluate conventional physical-chemical and biological treatment processes for removal of pollutants from retort water produced by in situ shale oil recovery methods. Prior to undertaking these studies, very little information had been reported on treatment of retort water. A treatment process train patterned after that generally used throughout the petroleum refining industry was envisioned for application to retort water. The treatment train would consist of processes for removing suspended matter, ammonia, biodegradable organics, and nonbiodegradable or refractory organics. The treatment processes evaluated include anaerobic digestion and activated sludge for removal of biodegradable organics and other oxidizable substances; activated carbon adsorption for removal of nonbiodegradable organics; steam stripping for ammonia removal; and chemical coagulation, sedimentation and filtration for removal of suspended matter. Preliminary cost estimates are provided.

  8. Chemical and biological aspects of water and sludge from treatment plants

    Energy Technology Data Exchange (ETDEWEB)

    Ottaviani, M.; Bonadonna, L.; Mancini, L.; Veschetti, E.; Gasbarro, M.; Lulli, G.; Zanobini, A.; Gabrieli, R.; Donia, D.; Divizia, M. (Istituto Superiore di Sanita' , Rome (Italy). Lab. di Igiene Ambientale Azienda Comunale Elettricita' ed Acque, Rome (Italy) Rome Univ. ' Tor Vergata' (Italy). Dip. di Sanita' Pubblica e Biologia Cellulare)

    Waste water and sewage sludge samples were collected from an urban waste water treatment plant in Rome (Italy). Chemical and biological (microbiological, virological and parassitological) analyses were performed for verifying the hygienic quality of the samples. On the basis of the results obtained, the possibility of utilizing the waste water and the sludge analyzed in view of a correct agricultural re-use can be taken into consideration.

  9. Behaviour of IPG waste forms bearing BaSO{sub 4} as the dominant sludge constituent generated from the treatment of water used for cooling the stricken power reactors

    Energy Technology Data Exchange (ETDEWEB)

    Amamoto, Ippei; Kobayashi, Hidekazu; Yokozawa, Takuma; Yamashita, Teruo; Nagai, Takayuki [Japan Atomic Energy Agency, Tokai-mura, Ibaraki Pref. (Japan); Kitamura, Naoto; Takebe, Hiromichi [Ehime University, Matsuyama, Ehime Pref. (Japan); Mitamura, Naoki; Tsuzuki, Tatsuya [Central Glass Co.,Ltd., Matsusaka, Mie Pref. (Japan)

    2013-07-01

    The great amount of water used for cooling the stricken power reactors at Fukushima Dai-ichi following the earthquake and tsunami of 11 March 2011 has resulted in accumulation of cooling water so-called the remaining water in some buildings. As the cooling water is subsequently contaminated by fission products (FPs) and some other radioactive substances, it is necessary to decontaminate this 'cooling water' to reduce the volume of liquid radioactive waste and to reuse it again for cooling the affected reactors. Some methods are applied to remove the radioactive substances from the cooling water. However, after treatments of water, there arises a secondary radioactive waste, the sludge. Steps are now taken to immobilize this sludge. In this paper, BaSO{sub 4}, as one of main constituents of the sludge, was chosen as an immobilizing target substance. The appropriate manufacturing condition of glass waste form for loading the sludge (BaSO{sub 4}) was studied and the chemical durability was evaluated by measuring the dissolution rate. For this experiment, the iron phosphate glass (IPG), which is known to possess a large loading capacity for a variety of chemical substances, was employed as the glass medium. Based on experimental results, it is evident that BaSO{sub 4} can be loaded into the IPG medium when it possesses the appropriate composition and melting temperature. During loading, BaSO{sub 4} converted into BaO, acting as a network modifier, which leads to enhanced stability of IPG. (authors)

  10. Plant wide chemical water stability modelling with PHREEQC for drinking water treatment

    NARCIS (Netherlands)

    Van der Helm, A.W.C.; Kramer, O.J.I.; Hooft, J.F.M.; De Moel, P.J.

    2015-01-01

    In practice, drinking water technologists use simplified calculation methods for aquatic chemistry calculations. Recently, the database stimela.dat is developed especially for aquatic chemistry for drinking water treatment processes. The database is used in PHREEQC, the standard in geohydrology for

  11. Plant wide chemical water stability modelling with PHREEQC for drinking water treatment

    NARCIS (Netherlands)

    Van der Helm, A.W.C.; Kramer, O.J.I.; Hooft, J.F.M.; De Moel, P.J.

    2015-01-01

    In practice, drinking water technologists use simplified calculation methods for aquatic chemistry calculations. Recently, the database stimela.dat is developed especially for aquatic chemistry for drinking water treatment processes. The database is used in PHREEQC, the standard in geohydrology for

  12. Utilization of municipal wastewater for cooling in thermoelectric power plants: Evaluation of the combined cost of makeup water treatment and increased condenser fouling

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Michael E. [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Theregowda, Ranjani B. [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept of Civil and Mechanical Engineering; Safari, Iman [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Abbasian, Javad [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Arastoopour, Hamid [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Dzombak, David A. [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept of Civil and Mechanical Engineering; Hsieh, Ming-Kai [Tamkang Univ., Taipei (Taiwan). Waer Resources Management and Policy Research Center; Miller, David C. [National Energy Technology Lab. (NETL), Morgantown, WV (United States)

    2013-10-01

    A methodology is presented to calculate the total combined cost (TCC) of water sourcing, water treatment and condenser fouling in the recirculating cooling systems of thermoelectric power plants. The methodology is employed to evaluate the economic viability of using treated municipal wastewater (MWW) to replace the use of freshwater as makeup water to power plant cooling systems. Cost analyses are presented for a reference power plant and five different tertiary treatment scenarios to reduce the scaling tendencies of MWW. Results indicate that a 550 MW sub-critical coal fired power plant with a makeup water requirement of 29.3 ML/day has a TCC of $3.0 - 3.2 million/yr associated with the use of treated MWW for cooling. (All costs USD 2009). This translates to a freshwater conservation cost of $0.29/kL, which is considerably lower than that of dry air cooling technology, $1.5/kL, as well as the 2020 conservation cost target set by the U.S. Department of Energy, $0.74/kL. Results also show that if the available price of freshwater exceeds that of secondary-treated MWW by more than $0.13-0.14/kL, it can be economically advantageous to purchase secondary MWW and treat it for utilization in the recirculating cooling system of a thermoelectric power plant.

  13. Low Maintenance Water Treatment for Heating and Cooling Systems: Review of Technologies and Guidelines for Implementation

    Science.gov (United States)

    2007-09-01

    by oxidizing bio- cides. Also, the relatively new phosphonate, manganese/aminophosphonic acid ( MAPA ) has shown some promise as a copper corrosion...Headquarters, U.S. Army Corps of Engineers HVAC heating, ventilating, and air conditioning IWC International Water Conference MAPA manganese/aminophosphonic...aninophosphonic acid ( MAPA ) Y Y Mercaptobenzothiazole (MBT) N Y Molybdate Y N Nitrite N Y Orthophosphate Y N Phosphonocarboxylic acid (POCA) Y N

  14. 18 CFR 420.44 - Cooling water.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Cooling water. 420.44 Section 420.44 Conservation of Power and Water Resources DELAWARE RIVER BASIN COMMISSION ADMINISTRATIVE MANUAL BASIN REGULATIONS-WATER SUPPLY CHARGES Charges; Exemptions § 420.44 Cooling water. Water...

  15. Solar-Enhanced Advanced Oxidation Processes for Water Treatment: Simultaneous Removal of Pathogens and Chemical Pollutants.

    Science.gov (United States)

    Tsydenova, Oyuna; Batoev, Valeriy; Batoeva, Agniya

    2015-08-14

    The review explores the feasibility of simultaneous removal of pathogens and chemical pollutants by solar-enhanced advanced oxidation processes (AOPs). The AOPs are based on in-situ generation of reactive oxygen species (ROS), most notably hydroxyl radicals •OH, that are capable of destroying both pollutant molecules and pathogen cells. The review presents evidence of simultaneous removal of pathogens and chemical pollutants by photocatalytic processes, namely TiO2 photocatalysis and photo-Fenton. Complex water matrices with high loads of pathogens and chemical pollutants negatively affect the efficiency of disinfection and pollutant removal. This is due to competition between chemical substances and pathogens for generated ROS. Other possible negative effects include light screening, competitive photon absorption, adsorption on the catalyst surface (thereby inhibiting its photocatalytic activity), etc. Besides, some matrix components may serve as nutrients for pathogens, thus hindering the disinfection process. Each type of water/wastewater would require a tailor-made approach and the variables that were shown to influence the processes-catalyst/oxidant concentrations, incident radiation flux, and pH-need to be adjusted in order to achieve the required degree of pollutant and pathogen removal. Overall, the solar-enhanced AOPs hold promise as an environmentally-friendly way to substitute or supplement conventional water/wastewater treatment, particularly in areas without access to centralized drinking water or sewage/wastewater treatment facilities.

  16. Solar-Enhanced Advanced Oxidation Processes for Water Treatment: Simultaneous Removal of Pathogens and Chemical Pollutants

    Directory of Open Access Journals (Sweden)

    Oyuna Tsydenova

    2015-08-01

    Full Text Available The review explores the feasibility of simultaneous removal of pathogens and chemical pollutants by solar-enhanced advanced oxidation processes (AOPs. The AOPs are based on in-situ generation of reactive oxygen species (ROS, most notably hydroxyl radicals •OH, that are capable of destroying both pollutant molecules and pathogen cells. The review presents evidence of simultaneous removal of pathogens and chemical pollutants by photocatalytic processes, namely TiO2 photocatalysis and photo-Fenton. Complex water matrices with high loads of pathogens and chemical pollutants negatively affect the efficiency of disinfection and pollutant removal. This is due to competition between chemical substances and pathogens for generated ROS. Other possible negative effects include light screening, competitive photon absorption, adsorption on the catalyst surface (thereby inhibiting its photocatalytic activity, etc. Besides, some matrix components may serve as nutrients for pathogens, thus hindering the disinfection process. Each type of water/wastewater would require a tailor-made approach and the variables that were shown to influence the processes—catalyst/oxidant concentrations, incident radiation flux, and pH—need to be adjusted in order to achieve the required degree of pollutant and pathogen removal. Overall, the solar-enhanced AOPs hold promise as an environmentally-friendly way to substitute or supplement conventional water/wastewater treatment, particularly in areas without access to centralized drinking water or sewage/wastewater treatment facilities.

  17. Solar-Enhanced Advanced Oxidation Processes for Water Treatment: Simultaneous Removal of Pathogens and Chemical Pollutants

    Science.gov (United States)

    Tsydenova, Oyuna; Batoev, Valeriy; Batoeva, Agniya

    2015-01-01

    The review explores the feasibility of simultaneous removal of pathogens and chemical pollutants by solar-enhanced advanced oxidation processes (AOPs). The AOPs are based on in-situ generation of reactive oxygen species (ROS), most notably hydroxyl radicals •OH, that are capable of destroying both pollutant molecules and pathogen cells. The review presents evidence of simultaneous removal of pathogens and chemical pollutants by photocatalytic processes, namely TiO2 photocatalysis and photo-Fenton. Complex water matrices with high loads of pathogens and chemical pollutants negatively affect the efficiency of disinfection and pollutant removal. This is due to competition between chemical substances and pathogens for generated ROS. Other possible negative effects include light screening, competitive photon absorption, adsorption on the catalyst surface (thereby inhibiting its photocatalytic activity), etc. Besides, some matrix components may serve as nutrients for pathogens, thus hindering the disinfection process. Each type of water/wastewater would require a tailor-made approach and the variables that were shown to influence the processes—catalyst/oxidant concentrations, incident radiation flux, and pH—need to be adjusted in order to achieve the required degree of pollutant and pathogen removal. Overall, the solar-enhanced AOPs hold promise as an environmentally-friendly way to substitute or supplement conventional water/wastewater treatment, particularly in areas without access to centralized drinking water or sewage/wastewater treatment facilities. PMID:26287222

  18. Chemical and bioanalytical assessments on drinking water treatments by quaternized magnetic microspheres.

    Science.gov (United States)

    Shi, Peng; Ma, Rong; Zhou, Qing; Li, Aimin; Wu, Bing; Miao, Yu; Chen, Xun; Zhang, Xuxiang

    2015-03-21

    This study aimed to compare the toxicity reduction performance of conventional drinking water treatment (CT) and a treatment (NT) with quaternized magnetic microspheres (NDMP) based on chemical analyses. Fluorescence excitation-emission-matrix combined with parallel factor analysis identified four components in source water of different rivers or lake, and the abundance of each component differed greatly among the different samples. Compared with the CT, the NT evidently reduced the concentrations of dissolved organic carbon, adsorbable organic halogens (AOX), bromide and disinfection by-products. Toxicological evaluation indicated that the NT completely eliminated the cytotoxicity, and greatly reduced the genotoxicity and oxidative stress of all raw water. In contrast, the CT increased the cytotoxicity of Taihu Lake and the Zhongshan River water, genotoxicity of Taihu Lake and the Mangshe River water, as well as the levels of superoxide dismutase and malondialdehyde of the Mangshe River water. Correlation analysis indicated that the AOX of the treated samples was significantly correlated with the genotoxicity and glutathione concentration, but exhibited no correlation with either of them for all the samples. As it can effectively reduce pollutant levels and the toxicities of drinking water, NDMP might be widely used for drinking water treatment in future.

  19. Thermodynamic Analysis of the Use a Chemical Heat Pump to Link a Supercritical Water-Cooled Nuclear Reactor and a Thermochemical Water-Splitting Cycle for Hydrogen Production

    Science.gov (United States)

    Granovskii, Mikhail; Dincer, Ibrahim; Rosen, Marc A.; Pioro, Igor

    Increases in the power generation efficiency of nuclear power plants (NPPs) are mainly limited by the permissible temperatures in nuclear reactors and the corresponding temperatures and pressures of the coolants in reactors. Coolant parameters are limited by the corrosion rates of materials and nuclear-reactor safety constraints. The advanced construction materials for the next generation of CANDU reactors, which employ supercritical water (SCW) as a coolant and heat carrier, permit improved “steam” parameters (outlet temperatures up to 625°C and pressures of about 25 MPa). An increase in the temperature of steam allows it to be utilized in thermochemical water splitting cycles to produce hydrogen. These methods are considered by many to be among the most efficient ways to produce hydrogen from water and to have advantages over traditional low-temperature water electrolysis. However, even lower temperature water splitting cycles (Cu-Cl, UT-3, etc.) require an intensive heat supply at temperatures higher than 550-600°C. A sufficient increase in the heat transfer from the nuclear reactor to a thermochemical water splitting cycle, without jeopardizing nuclear reactor safety, might be effectively achieved by application of a heat pump, which increases the temperature of the heat supplied by virtue of a cyclic process driven by mechanical or electrical work. Here, a high-temperature chemical heat pump, which employs the reversible catalytic methane conversion reaction, is proposed. The reaction shift from exothermic to endothermic and back is achieved by a change of the steam concentration in the reaction mixture. This heat pump, coupled with the second steam cycle of a SCW nuclear power generation plant on one side and a thermochemical water splitting cycle on the other, increases the temperature of the “nuclear” heat and, consequently, the intensity of heat transfer into the water splitting cycle. A comparative preliminary thermodynamic analysis is conducted

  20. Coagulation chemistries for silica removal from cooling tower water.

    Energy Technology Data Exchange (ETDEWEB)

    Nyman, May Devan; Altman, Susan Jeanne; Stewart, Tom

    2010-02-01

    The formation of silica scale is a problem for thermoelectric power generating facilities, and this study investigated the potential for removal of silica by means of chemical coagulation from source water before it is subjected to mineral concentration in cooling towers. In Phase I, a screening of many typical as well as novel coagulants was carried out using concentrated cooling tower water, with and without flocculation aids, at concentrations typical for water purification with limited results. In Phase II, it was decided that treatment of source or make up water was more appropriate, and that higher dosing with coagulants delivered promising results. In fact, the less exotic coagulants proved to be more efficacious for reasons not yet fully determined. Some analysis was made of the molecular nature of the precipitated floc, which may aid in process improvements. In Phase III, more detailed study of process conditions for aluminum chloride coagulation was undertaken. Lime-soda water softening and the precipitation of magnesium hydroxide were shown to be too limited in terms of effectiveness, speed, and energy consumption to be considered further for the present application. In Phase IV, sodium aluminate emerged as an effective coagulant for silica, and the most attractive of those tested to date because of its availability, ease of use, and low requirement for additional chemicals. Some process optimization was performed for coagulant concentration and operational pH. It is concluded that silica coagulation with simple aluminum-based agents is effective, simple, and compatible with other industrial processes.

  1. Replacement of chemical intensive water treatment processes with energy saving membrane. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Mickley, M.C.; Goering, S.W.

    1983-11-01

    The project investigated the use of charged ultrafiltration membranes to treat hard water. More specifically, the work was undertaken to (1) make charged ultrafiltration membranes to demonstrate the technical feasibility of the chemical grafting approach; (2) evaluate the market potential for charged ultrafiltration membranes; and (3) evaluate the cost and energy savings for using charged ultrafiltration as compared to lime-based clarification and other treatment methods. The results suggest that chemical grafting is a relatively simple, reproducible and low-cost way to modify existing substrate materials to give them enhanced transport performance. Process studies lead to the identification of good market potential for membrane processes using charged ultrafiltration membranes. Capital and operating costs relative to lime-based clarification are favorable for low- and medium-sized treatment plants. Finally, substantial energy savings are apparent as compared to lime-based precipitation systems which incur substantial energy consumption in the lime production and transportation steps.

  2. Technology for Water Treatment

    Science.gov (United States)

    1992-01-01

    There are approximately 500,000 water cooling towers in the United States, all of which must be kept clear of "scale" and corrosion and free of pollutants and bacteria. Electron Pure, Ltd. manufactures a hydro cooling tower conditioner as well as an automatic pool sanitizer. The pool sanitizer consists of two copper/silver electrodes placed in a chamber mounted in the pool's recirculation system. The tower conditioner combines the ionization system with a water conditioner, pump, centrifugal solids separator and timer. The system saves water, eliminates algae and operates maintenance and chemical free. The company has over 100 distributors in the U.S. as well as others in 20 foreign countries. The buildup of scale and corrosion is the most costly maintenance problem in cooling tower operation. Jet Propulsion Laboratory successfully developed a non-chemical system that not only curbed scale and corrosion, but also offered advantages in water conservation, cost savings and the elimination of toxic chemical discharge. In the system, ozone is produced by an on-site generator and introduced to the cooling tower water. Organic impurities are oxidized, and the dissolved ozone removes bacteria and scale. National Water Management, a NASA licensee, has installed its ozone advantage systems at some 200 cooling towers. Customers have saved money and eliminated chemical storage and discharge.

  3. Technology for Water Treatment (National Water Management)

    Science.gov (United States)

    1992-01-01

    The buildup of scale and corrosion is the most costly maintenance problem in cooling tower operation. Jet Propulsion Laboratory successfully developed a non-chemical system that not only curbed scale and corrosion, but also offered advantages in water conservation, cost savings and the elimination of toxic chemical discharge. In the system, ozone is produced by an on-site generator and introduced to the cooling tower water. Organic impurities are oxidized, and the dissolved ozone removes bacteria and scale. National Water Management, a NASA licensee, has installed its ozone advantage systems at some 200 cooling towers. Customers have saved money and eliminated chemical storage and discharge.

  4. Chemical and ecotoxicological assessments of water samples before and after being processed by a Water Treatment Plant

    Directory of Open Access Journals (Sweden)

    Regina Teresa Rosim Monteiro

    2014-01-01

    Full Text Available Physicochemical and ecotoxicological measurements were employed to appraise the water quality of the Corumbataí River raw water (RW intake, and that of its filtered (FW and treated (TW waters, processed by the Water Treatment Plant (WTP of Piracicaba (SP, Brazil during 2010. Some herbicides: ametrine, atrazine, simazine and tebuthiuron, were measured, with levels ranging from 0.01 to 10.3 µg L-1 . These were lower than those required to produce ecotoxicological effects to aquatic life based on published literature. Similarly, trihalomethanes, such as chloroform and bromodichloromethane produced as a result of the WTP process were also shown to be present in concentrations that would neither harm environmental nor human health. Elevated free chlorine concentrations found in FW and TW were credibly responsible for toxicity effects observed in algae and daphnids. (Pseudokirchneriella subcapitata and Daphnia magna. In contrast, results of toxicity testing conducted with Hydra attenuata suggested that this organism is resistant to free chorine and could be used for drinking water evaluations. Coupling bioassays with chemical analyses proved valuable to uncover putative cause-effect relationships existing between physical, chemical and toxic results, as well as in optimizing data interpretation of water quality.

  5. Dry cooling tower with water augmentation

    Energy Technology Data Exchange (ETDEWEB)

    Ireland, R.G.; Tramontini, V.N.

    1981-06-23

    An air cooling tower system is disclosed for condensing exhaust steam in power plants, that has water cooling augmentation to maintain the plant cooling capacity during high atmospheric temperature periods. The cooling tower includes a plurality of banks of brazed aluminum plate and fin type heat exchangers arranged in inverted ''v'' shaped sets. These heat exchangers cool ammonia used as the cooling fluid in the primary condenser for the power plant turbine exhaust steam. Each of these heat exchangers has a core consisting of a plurality of parallel aluminum plates spaced apart by fin assemblies that define a plurality of fluid passes. Approximately every other one of these passes has closed sides that open at the ends of the core to headers and define ammonia passes. The passes adjacent the ammonia passes are open at the sides and define air passes that permit the free flow of air transversely through the heat exchanger cores. An additional pass is provided adjacent every fourth one of the ammonia passes and these have closed sides and ends and define the passes for the cooling water. The water passes communicate at the bottom of the core with a water inlet manifold and at the top of the core with a water outlet manifold. The cooling tower system is designed so that at 55 degrees fahrenheit air temperatures or below, the cooling air alone will provide the necessary cooling for the ammonia to satisfy plant requirements. Above 55 degrees fahrenheit air temperature, cooling water from a separate water tank is pumped through the water passes to provide an additional cooling effect to maintain the design cooling capacity.

  6. Physical and Chemical Properties of Water Treatment Residue and the Characteristics of Red Pepper Growth by Using it

    OpenAIRE

    Park, Seok-Gon; Yahata, Hisashi; Kurosawa, Kiyoshi; Shin, Hyun-Tak

    2010-01-01

    Physical and chemical properties of the water treatment residue (WTR) and the WTR_, which contained compost (CP), were measured, and the effect of the properties on growth of the red pepper (Capsicum annuum‘Takanotsume’) was studied to reuse the WTR as an alternative material for decomposed granite soil (DGS). The physical properties of relative gas diffusivity (D/D_0), saturated hydraulic conductivity (K_s), water retention curve, porosity and plant-available water, and the chemical propert...

  7. Chemical treatment of animal feed and water for the control of Salmonella.

    Science.gov (United States)

    Wales, Andrew D; Allen, Vivien M; Davies, Robert H

    2010-01-01

    The control of Salmonella in animal feedstuffs is important, principally to protect the human food chain from contamination by Salmonella derived from infected animals. The transmission of Salmonella from animal feeds to animals, and onward to human food products, has been convincingly documented. This is especially important for chicken breeding and laying flocks and pigs, in view of the consequences of recent or imminent control legislation in the European Union. Animal feed ingredients, particularly animal and plant-derived protein meals, are frequently contaminated with Salmonella either from source or from processing plant, and recontamination in compounding mills is an additional problem. Several complementary strategies have been used to control this feed contamination, and these include a range of chemical treatments. The principal agents used are as follows: organic acids and their salts, formaldehyde, and bacterial membrane disruptors such as terpenes and essential oils. Experimental agents include chlorate compounds. Many products use blends of agents from the same or different chemical groups to achieve synergistic or combination effects. The present review draws upon published and company data to describe the various modes of action and efficacies of different chemical agents delivered in feed or in drinking water against Salmonella occurring in feed or in livestock environments. Reasons for the failure of protection are explored, along with problems in usage such as corrosion and reduced palatability. Given the wide array of products available with contrasting modes of action, the need for standardized tests of efficacy is also discussed.

  8. Feasibility assessment of vacuum cooling followed by immersion vacuum cooling on water-cooked pork.

    Science.gov (United States)

    Dong, Xiaoguang; Chen, Hui; Liu, Yi; Dai, Ruitong; Li, Xingmin

    2012-01-01

    Vacuum cooling followed by immersion vacuum cooling was designed to cool water-cooked pork (1.5±0.05 kg) compared with air blast cooling (4±0.5°C, 2 m/s), vacuum cooling (10 mbar) and immersion vacuum cooling. This combined cooling method was: vacuum cooling to an intermediate temperature of 25°C and then immersion vacuum cooling with water of 10°C to the final temperature of 10°C. It was found that the cooling loss of this combined cooling method was significantly lower (Pvacuum cooling. This combined cooling was faster (Pvacuum cooling in terms of cooling rate. Moreover, the pork cooled by combined cooling method had significant differences (P<0.05) in water content, color and shear force. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Recent state-of-the-art of biodegradable scale inhibitors for cooling-water treatment applications (Review)

    Science.gov (United States)

    Popov, K. I.; Kovaleva, N. E.; Rudakova, G. Ya.; Kombarova, S. P.; Larchenko, V. E.

    2016-02-01

    Scale formation is a challenge worldwide. Recently, scale inhibitors represent the best solution of this problem. The polyaminocarboxylic acids have been the first to be successfully applied in the field, although their efficacy was rather low. The next generation was developed on the grounds of polyphosphonic acids. The main disadvantage of these is associated with low biodegradation level. Polyacrylate-based phosphorous free inhibitors proposed as an alternative to phosphonates all also had low biodegradability. Thus, the main trend of recent R&D is the development of a new generation: environmentally friendly biodegradable scale inhibitors. The recent state of the word and domestic scale inhibitors markets is considered, the main industrial inhibitors manufacturers and marketed substances, as well as the general trends of R&D in the field, are characterized. It is demonstrated that most research is focused on biodegradable polymers and on phosponates with low phosphorus content, as well as on implementation of biodegradable fragments into polyacrylate matrixes for biodegradability enhancement. The problem of research results comparability is indicated along with domestic-made inhibitors quality and the gaps in scale inhibition mechanism. The actuality of fluorescent indicator fragment implementation into the scale inhibitor molecule for the better reagent monitoring in a cooling water system is specially emphasized.

  10. 化学水处理系统自用水回收利用%Chemical Water Treatment and Recovery for Water Utilization System

    Institute of Scientific and Technical Information of China (English)

    袁育亭; 刘政修

    2014-01-01

    According to the importance of water resource and the reality of the lack of analysis of chemical use, water recycling necessity. According to the typical chemical water treatment process, analysis of chemical water treatment system for water quality, water use rate. The chemical water treatment system for water (chemical pretreatment system and chemical osmosis equipment) should pay attention to the problem of recovery and utilization. The company of chemical water treatment system process, chemical water treatment system for the calculation of water, on the basis of chemical water treatment system for water quality, water quantity, in accordance with the“cascade use, decontamination triage”principle, established the system of chemical water treatment for water recycling and reuse scheme, and to the social and economic benefits the analysis.%依据水资源重要性及严重匮乏的现实情况,分析了化学自用水回收利用必要性。根据典型化学水处理工艺,分析了化学水处理系统自用水质量、自用水率。介绍了化学水处理系统自用水(化学预处理系统及化学反渗透设备)回收利用应该注意的问题。介绍了公司化学水处理系统工艺流程,计算了化学水处理系统自用水量,依据化学水处理系统自用水水质、水量,按照“梯级使用、清污分流”的原则,制订了化学水处理系统自用水分类回收和重复利用方案,并对社会及经济效益进行了分析。

  11. Reduction of Microbial and Chemical Contaminants in Water Using POU/POE & Mobile Treatment Technologies

    Science.gov (United States)

    POU/POE may be a cost-effective option for reductions of a particular chemical to achieve water quality compliance under certain situations and given restrictions. Proactive consumers seeking to reduce exposure to potential pathogens, trace chemicals, and nanoparticles not curre...

  12. Cooling by convection vs cooling by conduction for treatment of fever in critically ill adults.

    Science.gov (United States)

    Creechan, T; Vollman, K; Kravutske, M E

    2001-01-01

    Cooling with water-flow blankets, which are difficult to manipulate and interfere with patients' care, may be ineffective in controlling fever. To compare the effectiveness of cooling via convective airflow blankets with cooling via conductive water-flow blankets for treatment of fever in critically ill adults. A 2-group experimental design was used to compare cooling via convection (n = 20) with cooling via conduction (n = 17) in critically ill adults with an infection-related fever of 38.5 degrees C or greater. Esophageal temperature was measured every 15 minutes until a temperature of 38.0 degrees C was reached or 8 hours had elapsed. Alternative cooling measures were withheld unless the temperature increased to more than 40.0 degrees C. Data on nurses' satisfaction were collected, and complications related to each cooling method were examined. Temperatures decreased more rapidly in the airflow group (mean decrease, 0.377 degree C/h) than in the water-flow group (mean decrease, 0.163 degree C/h). A temperature of 38.0 degrees C was achieved more often in the airflow group (75% vs 47.1%). Fever (temperature > 38.5 degrees C) recurred sooner in the water-flow group (6.6 hours) than in the airflow group (22.2 hours). Both methods were easy to use. Compared with the water-flow blanket, the airflow blanket was recommended for future use twice as often and interfered less with patients' care. In critically ill adults with an infection or a suspected infection, cooling with an airflow blanket is more effective and more preferred for cooling than is cooling with a water-flow blanket.

  13. Treatment of surfactant stabilized oil-in-water emulsions by means of chemical oxidation and coagulation.

    Science.gov (United States)

    Kulik, N; Trapido, M; Veressinina, Y; Munter, R

    2007-12-01

    The model wastewater samples investigated in the current study represented oil-in-water (O/W) emulsions with small oil (diesel/black oil) and high surfactant (Anrol/Decon90) concentrations generated during washing of oil tankers or tank-wagons. Coagulation with aluminium sulphate, ferric chloride and lime milk, and chemical oxidation by hydrogen peroxide catalyzed ferrous ions were applied as traditional and advanced treatment processes, respectively. Coagulation proved more feasible for oil content removal than for COD reduction. Both COD and oil content removal, were higher if Anrol was used as a surface active agent. The comparison of wastewater samples with different oil products but the same detergent showed more effective black oil removal. Coagulation was found ineffective as a pre-treatment technology for biodegradability improvement and toxicity reduction in surfactant stabilized O/W emulsion wastewater samples. The application of Fenton chemistry showed significant COD, UV absorbance and BOD removal, but no improvement in wastewater samples biodegradability. The maximum COD reduction and oil content removal from wastewater samples was above 90%. The oxidation of wastewater containing Decon90 required higher dosages of the Fenton reagent than wastewater with Anrol. Both Anrol and Decon90 contaminated wastewater samples were found to be detoxified even after moderate hydrogen peroxide dosages had been applied in the oxidation step.

  14. Occurrence and removal of phenolic endocrine disrupting chemicals in the water treatment processes

    Science.gov (United States)

    Lv, Xuemin; Xiao, Sanhua; Zhang, Gang; Jiang, Pu; Tang, Fei

    2016-03-01

    This paper evaluated the occurrence and removal efficiency of four selected phenolic endocrine disrupting chemicals (bisphenol A (BPA), octylphenol (OP), nonylphenol (NP) and diethylstilbestrol (DES)) in two drinking waterworks in Jiangsu province which take source water from Taihu Lake. The recombined yeast estrogen screen (YES) and liquid chromatography tandem mass spectrometry (LC-MS/MS) were applied to assess the estrogenicity and detect the estrogens in the samples. The estrogen equivalents (EEQs) ranged from nd (not detected) to 2.96 ng/L, and the estrogenic activities decreased along the processes. Among the 32 samples, DES prevailed in all samples, with concentrations ranging 1.46-12.0 ng/L, BPA, OP and NP were partially detected, with concentrations ranging from nd to 17.73 ng/L, nd to 0.49 ng/L and nd to 3.27 ng/L, respectively. DES was found to be the main contributor to the estrogenicity (99.06%), followed by NP (0.62%), OP (0.23%) and BPA (0.09%). From the observation of treatment efficiency, the advanced treatment processes presented much higher removal ratio in reducing DES, the biodegradation played an important role in removing BPA, ozonation and pre-oxidation showed an effective removal on all the four estrogens; while the conventional ones can also reduce all the four estrogens.

  15. Asbestos in cooling-tower waters

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, B.A.G.

    1977-12-01

    Fill material in natural- or mechanical-draft cooling towers can be manufactured from a variety of materials, including asbestos cement or asbestos paper. To aid in the environmental impact assessment of cooling towers containing these asbestos types of fill, information on these materials was obtained from cooling-tower vendors and users. Samples of makeup, basin, and blowdown waters at a number of operating cooling towers were obtained, and identification and enumeration of asbestos in the samples were performed by transmission electron microscopy, selected-area electron diffraction, and energy-dispersive x-ray analysis. Asbestos fibers were detected in cooling-tower water at 10 of the 18 sites sampled in the study. At all but three sites, the fibers were detected in cooling-tower basin or blowdown samples, with no fibers detected in the makeup water. The fibers were identified as chrysotile at all sites except one. Concentrations were on the order of 10/sup 6/ to 10/sup 8/ fibers/liter of water, with mass concentrations between <0.1 ..mu..g/liter to 37 ..mu..g/liter. The maximum concentrations of asbestos fibers in air near ground due to drift from cooling towers were estimated (using models) to be on the order of asbestos concentrations reported for ambient air up to distances of 4 km downwind of the towers. The human health hazard due to abestos in drinking-water supplies is not clear. Based on current information, the concentrations of asbestos in natural waters after mixing with cooling-tower blowdown containing 10/sup 6/ to 10/sup 8/ fibers/liter will pose little health risk. These conclusions may need to be revised if future epidemiological studies so indicate.

  16. Progress of the Water Cooling System for CYCIAE-100

    Institute of Scientific and Technical Information of China (English)

    LI; Zhen-guo; WU; Long-cheng; LIU; Geng-guo

    2013-01-01

    The water cooling system for CYCIAE-100 has achieved a significant progress in 2013,its progress can be summarized as follows:1)The deionized water production equipment and the main circulating water cooling unit are installed and tested.2)The circulating water cooling unit for high power target and circulating water cooling unit for vacuum helium compressor are installed and tested.

  17. Desiccant Dewpoint Cooling System Independent of External Water Sources

    DEFF Research Database (Denmark)

    Bellemo, Lorenzo; Elmegaard, Brian; Markussen, Wiebke B.

    2015-01-01

    This paper presents a patent pending technical solution aiming to make desiccant cooling systems independent of external water sources, hence solving problems of water availability, cost and treatment that can decrease the system attractiveness. The solution consists in condensing water from the ...... to the desiccant dew-point system without water recovery, the required regeneration temperature increases and the system thermal efficiency decreases.......This paper presents a patent pending technical solution aiming to make desiccant cooling systems independent of external water sources, hence solving problems of water availability, cost and treatment that can decrease the system attractiveness. The solution consists in condensing water from...... the air that regenerates the desiccant dehumidifier, and using it for running the evaporative coolers in the system. A closed regeneration circuit is used for maximizing the amount of condensed water. This solution is applied to a system with a desiccant wheel dehumidifier and a dew point cooler, termed...

  18. DUSEL Facility Cooling Water Scaling Issues

    Energy Technology Data Exchange (ETDEWEB)

    Daily, W D

    2011-04-05

    Precipitation (crystal growth) in supersaturated solutions is governed by both kenetic and thermodynamic processes. This is an important and evolving field of research, especially for the petroleum industry. There are several types of precipitates including sulfate compounds (ie. barium sulfate) and calcium compounds (ie. calcium carbonate). The chemical makeup of the mine water has relatively large concentrations of sulfate as compared to calcium, so we may expect that sulfate type reactions. The kinetics of calcium sulfate dihydrate (CaSO4 {center_dot} 2H20, gypsum) scale formation on heat exchanger surfaces from aqueous solutions has been studied by a highly reproducible technique. It has been found that gypsum scale formation takes place directly on the surface of the heat exchanger without any bulk or spontaneous precipitation in the reaction cell. The kinetic data also indicate that the rate of scale formation is a function of surface area and the metallurgy of the heat exchanger. As we don't have detailed information about the heat exchanger, we can only infer that this will be an issue for us. Supersaturations of various compounds are affected differently by temperature, pressure and pH. Pressure has only a slight affect on the solubility, whereas temperature is a much more sensitive parameter (Figure 1). The affect of temperature is reversed for calcium carbonate and barium sulfate solubilities. As temperature increases, barium sulfate solubility concentrations increase and scaling decreases. For calcium carbonate, the scaling tendencies increase with increasing temperature. This is all relative, as the temperatures and pressures of the referenced experiments range from 122 to 356 F. Their pressures range from 200 to 4000 psi. Because the cooling water system isn't likely to see pressures above 200 psi, it's unclear if this pressure/scaling relationship will be significant or even apparent. The most common scale minerals found in the

  19. Hot water treatment to reduce incidence of black foot pathogens in young grapevines grown in cool climates

    Directory of Open Access Journals (Sweden)

    Carolyn BLEACH

    2013-09-01

    Full Text Available Black foot disease causes death of infected grapevines but management of this soil-borne disease by preventative measures such as pre-planting fungicide dips has not been totally effective. Hot water treatment (HWT; 50°C for 30 min of young dormant grapevine plants has been shown to significantly reduce infection. However, it has been reported to cause unacceptable damage to young vines in cooler climate countries like New Zealand, so this study examined the effects of different HWT protocols on the New Zealand black foot isolates. In vitro testing of different HWT protocols was conducted on conidia, mycelium and detached, inoculated grapevine canes using three isolates each of the species I. liriodendri (“C”. liriodendri and the complexes, I. radicicola (“C”. destructans and I. macrodidyma (“C”. macrodidymum. Heat treatments greater than 40°C for 5 min killed all conidia (P<0.001, and treatments greater than 47°C for 30 min inhibited (P≤0.003 further growth of treated mycelium plugs for all but one isolate. Within cane pieces, infection by Ilyonectria (“Cylindrocarpon” isolates was significantly reduced (P<0.001 by 30 min at 48.5 and 50°C. Additionally, these studies showed different responses to the different treatments for the three isolates of each species complex and differences between species. In field trials, HWT of 48.5 and 50°C for 30 min significantly reduced disease incidence in dormant plants to 0% (P≤0.001. This study confirmed that HWT of 48.5°C for 30 min could be used to eliminate black foot disease in dormant nursery grapevines grown in New Zealand prior to their use for establishing new vineyards.

  20. Evaporative cooling: water for thermal comfort

    Directory of Open Access Journals (Sweden)

    José Rui Camargo

    2008-08-01

    Full Text Available Evaporative cooling is an environmentally friendly air conditioning system that operates using induced processes of heat and mass transfer, where water and air are the working fluids. It consists, specifically, in water evaporation, induced by the passage of an air flow, thus decreasing the air temperature. This paper presents three methods that can be used as reference for efficient use of evaporative cooling systems, applying it to several Brazilian cities, characterized by different climates. Initially it presents the basic operation principles of direct and indirect evaporative cooling and defines the effectiveness of the systems. Afterwards, it presents three methods that allows to determinate where the systems are more efficient. It concludes that evaporative cooling systems have a very large potential to propitiate thermal comfort and can still be used as an alternative to conventional systems in regions where the design wet bulb temperature is under 24ºC.

  1. Integrated Chemical and Toxicological Investigation of UV-Chlorine/Chloramine Drinking Water Treatment

    Science.gov (United States)

    As the use of alternative drinking water treatment increases, it is important to understand potential public health•implications associated with these processes. The objective of this study was to evaluate the formation of disinfection byproducts (DBPs) and cytotoxicity of ...

  2. Integrated Chemical and Toxicological Investigation of UV-Chlorine/Chloramine Drinking Water Treatment

    Science.gov (United States)

    As the use of alternative drinking water treatment increases, it is important to understand potential public health•implications associated with these processes. The objective of this study was to evaluate the formation of disinfection byproducts (DBPs) and cytotoxicity of ...

  3. Impact of chemical treatments on the mechanical and water absorption properties of coconut fibre (Cocos nucifera reinforced polypropylene composites

    Directory of Open Access Journals (Sweden)

    Isiaka O. OLADELE

    2016-07-01

    Full Text Available In this work, chemically treated coconut fibres were used to reinforce Homopolymer Polypropylene in order to ascertain the effect of the treatments on the mechanical and water absorption properties of the composites produced. Coconut fibre was first extracted from its husk by soaking it in water and was dried before it was cut into 10 mm lengths. It was then chemically treated in alkali solution of sodium hydroxide (NaOH and potassium hydroxide (KOH in a shaker water bath. The treated coconut fibres were used as reinforcements in polypropylene matrix to produce composites of varied fibre weight contents; 2, 4, 6, 8 and 10 wt.%. Tensile and flexural properties were investigated using universal testing machine while water absorption test was carried out on the samples for 7 days. It was observed from the results that, NaOH treated samples gave the best tensile properties while KOH treated samples gave the best flexural and water repellent properties.

  4. Operational cost minimization in cooling water systems

    Directory of Open Access Journals (Sweden)

    Castro M.M.

    2000-01-01

    Full Text Available In this work, an optimization model that considers thermal and hydraulic interactions is developed for a cooling water system. It is a closed loop consisting of a cooling tower unit, circulation pump, blower and heat exchanger-pipe network. Aside from process disturbances, climatic fluctuations are considered. Model constraints include relations concerning tower performance, air flowrate requirement, make-up flowrate, circulating pump performance, heat load in each cooler, pressure drop constraints and climatic conditions. The objective function is operating cost minimization. Optimization variables are air flowrate, forced water withdrawal upstream the tower, and valve adjustment in each branch. It is found that the most significant operating cost is related to electricity. However, for cooled water temperatures lower than a specific target, there must be a forced withdrawal of circulating water and further makeup to enhance the cooling tower capacity. Additionally, the system is optimized along the months. The results corroborate the fact that the most important variable on cooling tower performance is not the air temperature itself, but its humidity.

  5. Heat transfer performance of water jet cooled mirror and its application in high power chemical lasers%射流式水冷镜换热性能及在高能化学激光器中的应用

    Institute of Scientific and Technical Information of China (English)

    李斌; 李兰; 焦路光; 刘亮; 周琼; 袁圣付; 刘文广

    2012-01-01

    加工了射流式水冷铜镜模型,采用红外热像仪测量了冷却过程中镜面温度分布云图,证明了射流式水冷镜冷却的均匀性.采用热电偶较精确地测量了铜镜冷却过程中镜面温度的变化,实验结果与数值模拟吻合较好,验证了射流式水冷镜数值模型的可靠性.结合高能化学激光器中水冷镜实际情况,对直线沟槽型水冷镜和射流式水冷镜的形变特性进行了分析.计算结果表明,高能化学激光器水冷镜必须承压加工才能使用,射流式水冷镜可以很好地应用于高能化学激光器.此外,进一步分析了冷却孔直径和数量这两个参数对大口径射流式水冷镜形变的影响,结果表明:在孔数一定的情况下,采用更大口径的冷却孔,镜面冷却速度快、镜面最大温度低,可以获得更小的镜面形变;采用更多的冷却孔可以获得更好的冷却效果.%The test model of water jet cooled copper mirror was made and temperature measurement of the mirror was carried out. The temperature uniformity of the water jet cooled copper mirror was proved by the measurements of infrared camera and experimental results of thermocouples agree well with the results of numerical simulation, which verified the reliability of the numerical model. The deformation characteristics of the water jet cooled mirror and the linear-channel water cooled mirror were analyzed in the scenario of high power chemical lasers. The results show that the water jet cooled mirror can be well used in high power chemical lasers and the mirror must be processed under certain pressure. In addition, the diameter and number of cooling holes were further analyzed to explore their effects on the deformation of water jet cooled mirror in high power chemical lasers. More holes with larger diameter lead to better cooling effects.

  6. A descaling treatment for aerated water, especially in cooling towers; Procede de traitement antitartre d`eau aeree, notamment dans les refrigerants atmospheriques

    Energy Technology Data Exchange (ETDEWEB)

    Delemont, F.; Mureau, P.

    1996-04-26

    Carbon dioxide is injected into the water aerating air, for example in the water flowing in a cooling tower; the dissolved carbon dioxide prevents scaling to take place on the heat exchange surfaces or leads to the dissolution of the deposited scale. This system has the advantage to avoid any acid use and thus polluting effluents. 2 refs.

  7. Supercritical-pressure light water cooled reactors

    CERN Document Server

    Oka, Yoshiaki

    2014-01-01

    This book focuses on the latest reactor concepts, single pass core and experimental findings in thermal hydraulics, materials, corrosion, and water chemistry. It highlights research on supercritical-pressure light water cooled reactors (SCWRs), one of the Generation IV reactors that are studied around the world. This book includes cladding material development and experimental findings on heat transfer, corrosion and water chemistry. The work presented here will help readers to understand the fundamental elements of reactor design and analysis methods, thermal hydraulics, materials and water

  8. Forward osmosis applied to evaporative cooling make-up water

    Energy Technology Data Exchange (ETDEWEB)

    Nicoll, Peter; Thompson, Neil; Gray, Victoria [Modern Water plc, Guildford (United Kingdom)

    2012-11-15

    Modern Water is in the process of developing a number of forward osmosis based technologies, ranging from desalination to power generation. This paper outlines the progress made to date on the development and commercial deployment of a forward osmosis based process for the production of evaporative cooling tower make-up water from impaired water sources, including seawater. Evaporative cooling requires significant amounts of good quality water to replace the water lost by evaporation, drift and blowdown. This water can be provided by conventional desalination processes or by the use of tertiary treated sewage effluent. The conventional processes are well documented and understood in terms of operation and power consumption. A new process has been successfully developed and demonstrated that provides make-up water directly, using a core platform 'forward osmosis' technology. This new technology shows significant promise in allowing various raw water sources, such as seawater, to be used directly in the forward osmosis step, thus releasing the use of scarce and valuable high grade water for other more important uses. The paper presents theoretical and operational results for the process, where it is shown that the process can produce make-up water at a fraction of the operational expenditure when compared to conventional processes, in particular regarding power consumption, which in some cases may be as low as 15 % compared to competing processes. Chemical additives to the cooling water (osmotic agent) are retained within the process, thus reducing their overall consumption. Furthermore the chemistry of the cooling water does not support the growth of Legionella pneumophila. Corrosion results are also reported. (orig.)

  9. Capillary Action may Cool Systems and Precisely balance Chemical Reactions

    Science.gov (United States)

    Kriske, Richard

    2011-10-01

    It is well known that it takes no work for Water to rise in a Capillary tube against the force of Gravity. There is a precise balance in this system that resembles Robert Millikan's ``Oil Drop'' experiment, where mass was balanced against the electrostatic force. If at the top of the capillary tube there is evaporation, one can see that the system is cooled as another water molecule has room to move up the column. Furthermore, if the evaporation process can be controlled one photon at a time, a precise balance is created between a photon, and the height/mass of the column. If other molecules are place in the column, they can be moved up and down the column, in a chromatograph way, in a fairly precise manner, by controlling evaporation and molecular weight. If in addition to all of this, the interface of the solution against the walls of the column have Fermi levels, it can be seen as a very precise Electrochemical Device. In the situation of nanotubes, as opposed to trees and plants, these properties can be used to create measure environmental properties and to Balance Chemical Reactions. Forests, and Plants may cool themselves and their environment using this process, and using this process coupled with more energetic photons through photosynthesis.

  10. Physico-chemical wastewater treatment

    NARCIS (Netherlands)

    Mels, A.R.; Teerikangas, E.

    2002-01-01

    Wastewater reclamation strategies aimed at closing industrial water cycles and recovery of valuable components will in most cases require a combination of wastewater treatment unit operations. Biological unit operations are commonly applied as the core treatment. In addition, physico-chemical unit o

  11. Physico-chemical wastewater treatment

    NARCIS (Netherlands)

    Mels, A.R.; Teerikangas, E.

    2002-01-01

    Wastewater reclamation strategies aimed at closing industrial water cycles and recovery of valuable components will in most cases require a combination of wastewater treatment unit operations. Biological unit operations are commonly applied as the core treatment. In addition, physico-chemical unit o

  12. Physico-chemical wastewater treatment

    NARCIS (Netherlands)

    Mels, A.R.; Teerikangas, E.

    2002-01-01

    Wastewater reclamation strategies aimed at closing industrial water cycles and recovery of valuable components will in most cases require a combination of wastewater treatment unit operations. Biological unit operations are commonly applied as the core treatment. In addition, physico-chemical unit

  13. Chemical surface modification of glass beads for the treatment of paper machine process waters

    Energy Technology Data Exchange (ETDEWEB)

    Jradi, Khalil, E-mail: khalil.jradi@uqtr.c [Centre de Recherche en Pates et Papiers, Universite du Quebec a Trois Rivieres, 3351 boul. des forges, C.P. 500, Trois Rivieres, QC, G9A-5H7 (Canada); Daneault, Claude [Canada Research Chair in Value-Added Paper Manufacturing (Canada); Chabot, Bruno [Centre de Recherche en Pates et Papiers, Universite du Quebec a Trois Rivieres, 3351 boul. des forges, C.P. 500, Trois Rivieres, QC, G9A-5H7 (Canada)

    2011-04-29

    Adsorption of detrimental contaminants on a solid sorbent is proposed to remove these contaminants from process waters to increase water recycling and reduce effluent loads in the papermaking industry. A self-assembly process of attaching (covalent grafting) cationic aminosilane molecules to glass beads was investigated. The existence and the hydrolytic stability of self-assembled monolayers and multilayers were confirmed by X-Ray Photoelectron Spectroscopy and contact angle measurements. Effects of reaction time and curing on aminosilane layer structures are also discussed. The curing step after silanization seems to be crucial in the hydrophobization of the quaternary ammonium silane coated onto glass beads, and curing could affect the final chemical structure of the ammonium groups of grafted organosilane. Results indicated that modified glass beads have a strong hydrophobicity, which is attributed to the hydrophobic property of the longest carbon chain grafted onto the glass surface. Adsorption of a model contaminant (stearic acid) onto chemically modified glass beads was determined using colloidal titration. Hydrophobic interactions could be the main driving force involved between the long carbon chains of stearic acid and the carbon chains of the aminosilane layers on glass bead surfaces. Finally, self-assembly processes applied onto glass beads may have two promising applications for papermaking and self-cleaning systems.

  14. Assessment of the water chemical quality improvement based on human health risk indexes: Application to a drinking water treatment plant incorporating membrane technologies.

    Science.gov (United States)

    López-Roldán, Ramón; Rubalcaba, Alicia; Martin-Alonso, Jordi; González, Susana; Martí, Vicenç; Cortina, Jose Luis

    2016-01-01

    A methodology has been developed in order to evaluate the potential risk of drinking water for the health of the consumers. The methodology used for the assessment considered systemic and carcinogenic effects caused by oral ingestion of water based on the reference data developed by the World Health Organisation (WHO) and the Risk Assessment Information System (RAIS) for chemical contaminants. The exposure includes a hypothetical dose received by drinking this water according to the analysed contaminants. An assessment of the chemical quality improvement of produced water in the Drinking Water Treatment Plant (DWTP) after integration of membrane technologies was performed. Series of concentration values covering up to 261 chemical parameters over 5 years (2008-2012) of raw and treated water in the Sant Joan Despí DWTP, at the lower part of the Llobregat River basin (NE Spain), were used. After the application of the methodology, the resulting global indexes were located below the thresholds except for carcinogenic risk in the output of DWTP, where the index was slightly above the threshold during 2008 and 2009 before the upgrade of the treatment works including membrane technologies was executed. The annual evolution of global indexes showed a reduction in the global values for all situations: HQ systemic index based on RAIS dropped from 0.64 to 0.42 for surface water and from 0.61 to 0.31 for drinking water; the R carcinogenic index based on RAIS was negligible for input water and varied between 4.2×10(-05) and 7.4×10(-06) for drinking water; the W systemic index based on the WHO data varied between 0.41 and 0.16 for surface water and between 0.61 and 0.31 for drinking water. A specific analysis for the indexes associated with trihalomethanes (THMs) showed the same pattern.

  15. Anomalous Effects in Air While Cooling Water

    CERN Document Server

    Sardo, Rachel

    2008-01-01

    Water is a unique compound with many anomalies and properties not fully understood. Designing an experiment in the laboratory to study such anomalies, we set up a series of experiments where a tube was placed inside a sealed container with thermocouples attached to the outer surface of the tube and in the air adjacent to the tube. Alternately, deionized water and other compounds were added to the tube and cooled to freezing. Several of the thermocouples suspended in the air and adjacent to the tube showed thermal oscillations as the overall temperature of the container was decreasing. The temperature of the thermocouples increased and decreased in a sinusoidal way during part of the cool down to freezing. Thermal oscillations as large as 3 degrees Celsius were recorded with typical frequencies of about 5 oscillations per minute.

  16. Essentials of water systems design in the oil, gas, and chemical processing industries

    CERN Document Server

    Bahadori, Alireza; Boyd, Bill

    2013-01-01

    Essentials of Water Systems Design in the Oil, Gas and Chemical Processing Industries provides valuable insight for decision makers by outlining key technical considerations and requirements of four critical systems in industrial processing plants—water treatment systems, raw water and plant water systems, cooling water distribution and return systems, and fire water distribution and storage facilities. The authors identify the key technical issues and minimum requirements related to the process design and selection of various water supply systems used in the oil, gas, and chemical processing industries. This book is an ideal, multidisciplinary work for mechanical engineers, environmental scientists, and oil and gas process engineers.

  17. On synthesis and optimization of cooling water systems with multiple cooling towers

    CSIR Research Space (South Africa)

    Gololo, KV

    2011-01-01

    Full Text Available research on cooling water systems has focused mainly on heat exchanger network thus excluding the interaction between heat exchanger network and the cooling towers. This paper presents a technique for grassroot design of cooling water system for wastewater...

  18. Effect of water treatment additives on lime softening residual trace chemical composition--implications for disposal and reuse.

    Science.gov (United States)

    Cheng, Weizhi; Roessler, Justin; Blaisi, Nawaf I; Townsend, Timothy G

    2014-12-01

    Drinking water treatment residues (WTR) offer potential benefits when recycled through land application. The current guidance in Florida, US allows for unrestricted land application of lime softening WTR; alum and ferric WTR require additional evaluation of total and leachable concentrations of select trace metals prior to land application. In some cases a mixed WTR is produced when lime softening is accompanied by the addition of a coagulant or other treatment chemical; applicability of the current guidance is unclear. The objective of this research was to characterize the total and leachable chemical content of WTR from Florida facilities that utilize multiple treatment chemicals. Lime and mixed lime WTR samples were collected from 18 water treatment facilities in Florida. Total and leachable concentrations of the WTR were measured. To assess the potential for disposal of mixed WTR as clean fill below the water table, leaching tests were conducted at multiple liquid to solid ratios and under reducing conditions. The results were compared to risk-based soil and groundwater contamination thresholds. Total metal concentrations of WTR were found to be below Florida soil contaminant thresholds with Fe found in the highest abundance at a concentration of 3600 mg/kg-dry. Aluminum was the only element that exceeded the Florida groundwater contaminant thresholds using SPLP (95% UCL = 0.23 mg/L; risk threshold = 0.2 mg/L). Tests under reducing conditions showed elevated concentrations of Fe and Mn, ranging from 1 to 3 orders of magnitude higher than SPLP leachates. Mixed lime WTR concentrations (total and leachable) were lower than the ferric and alum WTR concentrations, supporting that mixed WTR are appropriately represented as lime WTR. Testing of WTR under reducing conditions demonstrated the potential for release of certain trace metals (Fe, Al, Mn) above applicable regulatory thresholds; additional evaluation is needed to assess management options where

  19. Understanding the impacts of allocation approaches during process-based life cycle assessment of water treatment chemicals.

    Science.gov (United States)

    Alvarez-Gaitan, Juan P; Peters, Gregory M; Short, Michael D; Schulz, Matthias; Moore, Stephen

    2014-01-01

    Chemicals are an important component of advanced water treatment operations not only in terms of economics but also from an environmental standpoint. Tools such as life cycle assessment (LCA) are useful for estimating the environmental impacts of water treatment operations. At the same time, LCA analysts must manage several fundamental and as yet unresolved methodological challenges, one of which is the question of how best to "allocate" environmental burdens in multifunctional processes. Using water treatment chemicals as a case study example, this article aims to quantify the variability in greenhouse gas emissions estimates stemming from methodological choices made in respect of allocation during LCA. The chemicals investigated and reported here are those most important to coagulation and disinfection processes, and the outcomes are illustrated on the basis of treating 1000 ML of noncoagulated and nondisinfected water. Recent process and economic data for the production of these chemicals is used and methodological alternatives for solving the multifunctionality problem, including system expansion and mass, exergy, and economic allocation, are applied to data from chlor-alkali plants. In addition, Monte Carlo simulation is included to provide a comprehensive picture of the robustness of economic allocation results to changes in the market price of these industrial commodities. For disinfection, results demonstrate that chlorine gas has a lower global warming potential (GWP) than sodium hypochlorite regardless of the technique used to solve allocation issues. For coagulation, when mass or economic allocation is used to solve the multifunctionality problem in the chlor-alkali facility, ferric chloride was found to have a higher GWP than aluminum sulfate and a slightly lower burden where system expansion or exergy allocation are applied instead. Monte Carlo results demonstrate that when economic allocation is used, GWP results were relatively robust and resilient

  20. Free Cooling in the Water Cooling Towers: a Case Study for Istanbul, Turkey

    OpenAIRE

    KOÇ, İbrahim; PARMAKSIZOGLU, Cem

    2013-01-01

    Energy saving in cooling towers which is used for cooling to the hot water can be significantly improved by using free cooling application. This application is commonly known economizer cycle and when outside conditions are suitable for cooling, it is used for. In this study, the free cooling is applied for the cold water necessity which is supplied by the chiller of the cooling tower in the factory which is available in Istanbul. The results show that the ...

  1. Study on physico - chemical properties of Korean anthracite for utilization development - application to filtering materials for waste water treatment

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong Soo; Lee, Jae Ho; Park, Suk Whan [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1996-12-01

    This research was initiated for the development of filtering materials those can be used in waste water treatment sites. The selected Jangseong coal for filtering material has low Hardgrove Grindability Index (HGI : 38.38) and crushed two granule size. One is 1-2 mm size (effective size : 0.77 mm, uniformity coefficient : 1.70) and the other is 2-4 mm size (2.04 mm, 1.37) First, we had application test to find out the possibility of 2-4 mm sample for using water filtering material instead of silica sand in Sandflo filter. The result were unsuitable for treatment efficiency and micron size granule. But it will be solution with control of granule size and washing of coal. For feasibility study, the small scale of filtration tester was built on the waste water treatment plant of Lotte-chilsung beverage Co. to use the precipitated water during filtration test processed by purifying system. Measurement items are filtration rate, temperature of waste water, Electric Conductivity (EC), pH, turbidity, Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Nitrogen Nitrate (NO{sub 3}-N), Organophosphorus and trace elements content (Zn, Al, Fe, Mg, K) of the supplied water and filtered water were carried out to find the filtration capacity of coal. The results indicated decreasing degree in turbidity (1-2 mm : 15.08 %, 2-4 mm : 11.58 %), COD (1-2 mm : 5.76 %, 2-4 mm : 5.49 %) and increasing degree in DO (1-2 mm : 11.25 %, 2-4 mm : 10 %). Trace elements removal degree of filtered waste water were about 30 % for Fe and 5 % for K. (author). 32 refs., tabs., figs.

  2. 多氨基多醚基亚甲基膦酸(PAPEMP)在乙烯生产循环冷却水处理中的应用%Application of Polyamino Polyether Methylene Phosphonate (PAPEMP) in Recirculated Cooling Water Treatment System for Ethylene Production

    Institute of Scientific and Technical Information of China (English)

    蒋毅章; 季淑浥; 赵士峰

    2012-01-01

    Dynamic simulation test using polyamino polyether methylene phosphonate (PAPEMP ) scheme and phosphonate zinc scheme in recirculated cooling water treatment system for ethylene production were introduced. In ethylene plant cooling water system, PAPEMP treatment scheme substitutes for phosphonate zinc treatment scheme, which can obtain satisfactory corrosion protection and scale control under condition of heat transfer quantity and concentration ratio improved. Hie PAPEMP treatment scheme reduces chemical cleaning of recirculated cooling water system, which means the ethylene equipment can operate chronically and stably.%介绍了多氨基多醚基亚甲基膦酸(PAPEMP)处理方案与膦酸盐/锌盐处理方案在乙烯生产循环冷却水处理中的动态试验.在乙烯生产装置循环水系统,使用PAPEMP处理方案代替膦酸盐/锌盐处理方案,在热负荷增加及高浓缩倍数等苛刻条件下系统腐蚀和结垢控制良好.PAPEMP方案减少循环水系统的清洗次数,满足了乙烯装置长周期稳定运行的要求.

  3. The effect of cooling water on magnet vibrations

    CERN Document Server

    Redaelli, S; Coosemans, Williame; Schnell, Wolfgang

    2002-01-01

    The quadrupole magnets in the CLIC Test Facility II (CTF2) incorporate a water cooling circuit. In the frame-work of the CLIC stability study, the mechanical vibrations of the magnets were measured for different flows of cool-ing water. We present the results and compare them with simple theoretical estimates. It is shown that the vibra-tion requirements of the Compact LInear Collider (CLIC) quadrupoles with cooling water can basically be met.

  4. 循环冷却水浊度偏高原因及处理%Causes and Treatment of High Turbidity of Circulating Cooling Water

    Institute of Scientific and Technical Information of China (English)

    普宏波; 何应贵

    2016-01-01

    循环冷却水浊度是循环水装置运行中重要指标之一。对水富云天化有限公司有机生产装置循环冷却水浊度偏高的原因进行分析,并提出相应对策。%Water turbidity of circulating cooling water is one of the important indicators of plant opera-tion.The causes of high turbidity in Shuifu Yuntianhua Ltd were analyzed,and the corresponding counter-measures were proposed.

  5. Application of Cooling Water in Controlled Runout Table Cooling on Hot Strip Mill

    Institute of Scientific and Technical Information of China (English)

    LIU Zheng-dong; I V Samarasekera

    2004-01-01

    The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip. The heat of a hot steel strip is mainly extracted by cooling water during runout. In order to study the heat transfer by water jet impingement boiling during runout, a pilot facility was constructed at the University of British Columbia. On this pilot facility, the water jet impingement tests were carried out under various cooling conditions to investigate the effect of processing parameters, such as cooling water temperature, water jet impingement velocity, initial strip temperature, water flow rate, water nozzle diameter and array of water nozzles, on the heat transfer of heated strip. The results obtained contribute to the optimization of cooling water during runout.

  6. REMOVAL OF CHEMICAL AND MICROBIAL CONTAMINANTS IN DRINKING WATER - WATTS PREMIER M-2400 POINT-OF-ENTRY REVERSE OSMOSIS DRINKINGWATER TREATMENT SYSTEM

    Science.gov (United States)

    The Watts Premier M-2400 POE RO Drinking Water Treatment System was tested at the NSF Drinking Water Treatment Systems Laboratory for removal of the viruses fr and MS2, the bacteria Brevundimonas diminuta, and chemicals aldicarb, benzene, cadmium, carbofuran, cesium, chl...

  7. REMOVAL OF CHEMICAL AND MICROBIAL CONTAMINANTS IN DRINKING WATER - WATTS PREMIER M-2400 POINT-OF-ENTRY REVERSE OSMOSIS DRINKINGWATER TREATMENT SYSTEM

    Science.gov (United States)

    The Watts Premier M-2400 POE RO Drinking Water Treatment System was tested at the NSF Drinking Water Treatment Systems Laboratory for removal of the viruses fr and MS2, the bacteria Brevundimonas diminuta, and chemicals aldicarb, benzene, cadmium, carbofuran, cesium, chl...

  8. Development of methods for the decrease in instability of recycling water of conjugated closed-circuit cooling system of HPP

    Science.gov (United States)

    Chichirov, A. A.; Chichirova, N. D.; Vlasov, S. M.; Lyapin, A. I.; Misbakhov, R. Sh.; Silov, I. Yu.; Murtazin, A. I.

    2016-10-01

    On Russian HPPs, conjugated closed-circuit cooling systems, where purge water is used as initial for water-treatment facilities, are widespread. For this reason, it is impossible to use general methods for the stabilization treatment of recycling water in order to prevent scale formation in the units of a system, namely, turbine condensers and cooling towers. In this paper, the methods for the decrease in the instability of recycling water using the methods of chemical engineering, such as stabilization and synchronization of flows and organization of recycles, are suggested. The results of an industrial experiment on the implementation of stabilization treatment of recycling water by the organization of recycle are given. The experiment was carried out on Kazan CHPP-3. The flow scheme involved the recycle of chemically purified water (CPW) for the heat network make-up to the closed-circuit cooling system. The experiment was carried out at three stages with the gradual change of the consumption of the recycle, namely, 0, 50, and 100 t/h. According to the results of experiments, the reliable decrease in the rate of the sedimentation was recorded on the units of the system, namely, turbine condenser and chimney-type cooling tower. This is caused by two reasons. Firstly, this is periodic excessive concentration of recycling water due to the nonstationary character of inlet and outlet flows. Secondly, this is seasonal (particularly, in the summer period) exceeding of the evaporation coefficient. As a result of stabilization and synchronization of flows and organization of recycles, the quality of clarified and chemically purified water for the heat network make-up increases and the corrosion of iron- and copper-containing structural materials decreases. A natural decrease in temperature drop on the operating turbine condensers is mentioned.

  9. USE of mine pool water for power plant cooling.

    Energy Technology Data Exchange (ETDEWEB)

    Veil, J. A.; Kupar, J. M .; Puder, M. G.

    2006-11-27

    Water and energy production issues intersect in numerous ways. Water is produced along with oil and gas, water runs off of or accumulates in coal mines, and water is needed to operate steam electric power plants and hydropower generating facilities. However, water and energy are often not in the proper balance. For example, even if water is available in sufficient quantities, it may not have the physical and chemical characteristics suitable for energy or other uses. This report provides preliminary information about an opportunity to reuse an overabundant water source--ground water accumulated in underground coal mines--for cooling and process water in electric generating facilities. The report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL), which has implemented a water/energy research program (Feeley and Ramezan 2003). Among the topics studied under that program is the availability and use of ''non-traditional sources'' of water for use at power plants. This report supports NETL's water/energy research program.

  10. Conceptual design of a water cooled breeder blanket for CFETR

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Songlin, E-mail: slliu@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Pu, Yong; Cheng, Xiaoman [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Li, Jia; Peng, ChangHong [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027 (China); Ma, Xuebing [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Chen, Lei [School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027 (China)

    2014-10-15

    Highlights: • We proposed a water cooled ceramic breeder blanket with superheated steam. • Superheated steam is generated at the first wall and the front part of breeder zone. • Superheated steam has negligible impact on neutron absorption by coolant in FW and improves TBR. • The superheated steam at higher temperature can improve thermal efficiency. - Abstract: China Fusion Engineering Test Reactor (CFETR) is an ITER-like superconducting tokamak reactor. Its major radius is 5.7 m, minor radius is 1.6 m and elongation ratio is 1.8. Its mission is to achieve 50–200 MW of fusion power, 30–50% of duty time factor, and tritium breeding ratio not less than 1.2 to ensure the self-sufficiency. As one of the breeding blanket candidates for CFETR, a water cooled breeder blanket with superheated steam is proposed and its conceptual design is being carried out. In this design, sub-cooling water at 265 °C under the pressure of 7 MPa is fed into cooling plates in breeding zone and is heated up to 285 °C with saturated steam generated, and then this steam is pre-superheated up to 310 °C in first wall (FW), final, the pre-superheated steam coming from several blankets is fed into the other one blanket to superheat again up to 517 °C. Due to low density of superheated steam, it has negligible impact on neutron absorption by coolant in FW so that the high energy neutrons entering into breeder zone moderated by water in cooling plate help enhance tritium breeding by {sup 6}Li(n,α)T reaction. Li{sub 2}TiO{sub 3} pebbles and Be{sub 12}Ti pebbles are chosen as tritium breeder and neutron multiplier respectively, because Li{sub 2}TiO{sub 3} and Be{sub 12}Ti are expected to have better chemical stability and compatibility with water in high temperature. However, Be{sub 12}Ti may lead to a reduction in tritium breeding ratio (TBR). Furthermore, a spot of sintered Be plate is used to improve neutron multiplying capacity in a multi-layer structure. As one alternative option

  11. Survival of the faucet snail after chemical disinfection, pH extremes, and heated water bath treatments

    Science.gov (United States)

    Mitchell, A.J.; Cole, R.A.

    2008-01-01

    The faucet snail Bithynia tentaculata, a nonindigenous aquatic snail from Eurasia, was introduced into Lake Michigan in 1871 and has spread to the mid-Atlantic states, the Great Lakes region, Montana, and most recently, the Mississippi River. The faucet snail serves as intermediate host for several trematodes that have caused large-scale mortality among water birds, primarily in the Great Lakes region and Montana. It is important to limit the spread of the faucet snail; small fisheries equipment can serve as a method of snail distribution. Treatments with chemical disinfection, pH extremes, and heated water baths were tested to determine their effectiveness as a disinfectant for small fisheries equipment. Two treatments eliminated all test snails: (1) a 24-h exposure to Hydrothol 191 at a concentration of at least 20 mg/L and (2) a treatment with 50??C heated water for 1 min or longer. Faucet snails were highly resistant to ethanol, NaCl, formalin, Lysol, potassium permanganate, copper sulfate, Baquacil, Virkon, household bleach, and pH extremes (as low as 1 and as high as 13).

  12. Numerical Modelling and Simulation of Chemical Reactions in a Nano-Pulse Discharged Bubble for Water Treatment

    Science.gov (United States)

    He, Yuchen; Satoshi, Uehara; Hidemasa, Takana; Hideya, Nishiyama

    2016-09-01

    A zero-dimensional model to simulate a nano-pulse-discharged bubble in water was developed. The model consists of gas and liquid phases corresponding to the inside and outside of the bubble, respectively. The diffusions of chemical species from the gas to the liquid phase through the bubble interface was also investigated. The initial gas is Ar, but includes a little H2O and O2 in the bubble. The time evolution of the OH concentration in the liquid phase was mainly investigated as an important species for water treatment. It was shown that OH was generated in the bubble and then diffused into the liquid. With the application of a continuous nano-pulse discharge, more OH radicals were generated as the frequency increased at a low voltage for a given power consumption. supported partially by Japan Society for the Promotion of Science (JSPS) KAKENHI (No. 26249015)

  13. Electrochemistry of Water-Cooled Nuclear Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Macdonald, Dgiby; Urquidi-Macdonald, Mirna; Pitt, Jonathan

    2006-08-08

    This project developed a comprehensive mathematical and simulation model for calculating thermal hydraulic, electrochemical, and corrosion parameters, viz. temperature, fluid flow velocity, pH, corrosion potential, hydrogen injection, oxygen contamination, stress corrosion cracking, crack growth rate, and other important quantities in the coolant circuits of water-cooled nuclear power plants, including both Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). The model is being used to assess the three major operational problems in Pressurized Water Reactors (PWR), which include mass transport, activity transport, and the axial offset anomaly, and provide a powerful tool for predicting the accumulation of SCC damage in BWR primary coolant circuits as a function of operating history. Another achievement of the project is the development of a simulation tool to serve both as a training tool for plant operators and as an engineering test-bed to evaluate new equipment and operating strategies (normal operation, cold shut down and others). The development and implementation of the model allows us to estimate the activity transport or "radiation fields" around the primary loop and the vessel, as a function of the operating parameters and the water chemistry.

  14. Corrosion induced clogging and plugging in water-cooled generator cooling circuit

    Energy Technology Data Exchange (ETDEWEB)

    Park, B.G.; Hwang, I.S. [Dept. of Nuclear Engineering, Seoul National Univ. (Korea, Republic of); Rhee, I.H. [Dept. of Chemical Engineering, Soonchunhyang Univ. (Korea, Republic of); Kim, K.T.; Chung, H.S. [Korea Electric Power Research Inst. (Korea, Republic of)

    2002-07-01

    Water-cooled electrical generators have been experienced corrosion-related problems that are restriction of flow through water strainers caused by collection of excessive amounts of copper corrosion products (''clogging''), and restriction of flow through the copper strands in the stator bars caused by growth or deposition of corrosion products on the walls of the hollow strands (''plugging''). These phenomena result in unscheduled shutdowns that would be a major concern because of the associated loss in generating capacity. Water-cooled generators are operated in one of two modes. They are cooled either with aerated water (dissolved oxygen >2 ppm) or with deaerated water (dissolved oxygen <50 ppb). Both modes maintain corrosion rates at satisfactorily low levels as long as the correct oxygen concentrations are maintained. However, it is generally believed that very much higher copper corrosion rates result at the intermediate oxygen concentrations of 100-1000 ppb. Clogging and plugging are thought to be associated with these intermediate concentrations, and many operators have suggested that the period of change from high-to-low or from low-to-high oxygen concentration is particularly damaging. In order to understand the detailed mechanism(s) of the copper oxide formation, release and deposition and to identify susceptible conditions in the domain of operating variables, a large-scale experiments are conducted using six hollow strands of full length connected with physico-chemically scaled generator cooling water circuit. To ensure a close simulation of thermal-hydraulic conditions in a generator stator, strands of the loop will be ohmically heated using AC power supply. Experiments is conducted to cover oxygen excursions in both high dissolved oxygen and low dissolved oxygen conditions that correspond to two representative operating condition at fields. A thermal upset condition is also simulated to examine the impact of

  15. DRINKING WATER TREATMENT

    Science.gov (United States)

    The purpose of water treatment is threefold: 1. To improve the aethetic quality ofwater, 2. to remove toxic or health-hazardous chemicals, 3. to remove and/or inactivate any disease causing microorganisms. These objectives should be accomplished using a reasonable safety factor...

  16. Selective brain cooling reduces water turnover in dehydrated sheep.

    Directory of Open Access Journals (Sweden)

    W Maartin Strauss

    Full Text Available In artiodactyls, arterial blood destined for the brain can be cooled through counter-current heat exchange within the cavernous sinus via a process called selective brain cooling. We test the hypothesis that selective brain cooling, which results in lowered hypothalamic temperature, contributes to water conservation in sheep. Nine Dorper sheep, instrumented to provide measurements of carotid blood and brain temperature, were dosed with deuterium oxide (D2O, exposed to heat for 8 days (40 ◦C for 6-h per day and deprived of water for the last five days (days 3 to 8. Plasma osmolality increased and the body water fraction decreased over the five days of water deprivation, with the sheep losing 16.7% of their body mass. Following water deprivation, both the mean 24h carotid blood temperature and the mean 24h brain temperature increased, but carotid blood temperature increased more than did brain temperature resulting in increased selective brain cooling. There was considerable inter-individual variation in the degree to which individual sheep used selective brain cooling. In general, sheep spent more time using selective brain cooling, and it was of greater magnitude, when dehydrated compared to when they were euhydrated. We found a significant positive correlation between selective brain cooling magnitude and osmolality (an index of hydration state. Both the magnitude of selective brain cooling and the proportion of time that sheep spent selective brain cooling were negatively correlated with water turnover. Sheep that used selective brain cooling more frequently, and with greater magnitude, lost less water than did conspecifics using selective brain cooling less efficiently. Our results show that a 50 kg sheep can save 2.6L of water per day (~60% of daily water intake when it employs selective brain cooling for 50% of the day during heat exposure. We conclude that selective brain cooling has a water conservation function in artiodactyls.

  17. The application and management of weak alkalization treatment in generator stator cooling water system%微碱处理在发电机定子冷却水系统改造中的应用与管理

    Institute of Scientific and Technical Information of China (English)

    韩西印

    2009-01-01

    发电机定子冷却水长期采用除盐水和凝结水做为补充水,小混床+间断换水处理的运行方式时,pH值经常小于7.0,铜离子含量大多数时间大于40μg/L,不能满足DL/T801-2002要求.采用定子冷却水微碱处理系统后,定子冷却水水质明显改善:电导率0.1 μS/cm~0.8 μS/cm,pH值7.2~7.8,铜离子小于40μg/L.%Generator stator cooling water uses desalted water and condensate water as the water supply, when the operating mode of small mix-bed adding intermittent exchange water treatment, the pH value is often less than 7.0, the copper ion content is more than 40 μg/L, which can't meet the demand of DL/T801-2002, after using weak alkalization treatment in stator cooling water system, improves the quality of stator cooling water obviously: the conductance is 0.1 μS/cm~0.8μS/cm, the pH value is in 7.2~7.8, the copper ion content is less than 40 μg/L.

  18. Progress of the Water Cooling System for CYCIAE-100

    Institute of Scientific and Technical Information of China (English)

    LI; Zhen-guo; WU; Long-cheng; LIU; Geng-guo

    2012-01-01

    <正>According to the general construction schedule of the BRIF project, the water cooling system for CYCIAE-100 has achieved a significant progress in 2012, its progress can be summarized as follows. 1) Inside wiring of 7 water distribution cabinets were completed. 2) Manufacturer selection of circulating water cooling unit and deionized water production equipment was decided after market survey and bidding process. The contracts were formally signed in February. The deionized water production equipment was ready in May and the circulating water cooling

  19. Process water - waste water - cooling water. Papers; Prozesswasser/Abwasser/Kuehlwasser. Vortraege

    Energy Technology Data Exchange (ETDEWEB)

    Liese, F. (comp.)

    2002-07-01

    The 39th Metallurgical Seminar focused on water. Modern technologies for water purification and treatment were presented, legal boundary conditions were discussed, and aspects of process water, waste water and cooling water were gone into. Although the boundaries between these three types of water cannot be clearly defined, materials recovery is the prevalent aspect in process water treatment while waste water treatment primarily aims at reducing pollutant concentrations so that both environmental aspects and technical quality standards will be met. This proceedings volume attempts to give its readers a more precise picture of the issues at hand by presenting fundamental research, ecological and legal specifications, and selected examples of industrial applications. [German] Das 39. Metallurgische Seminar beschaeftigt sich mit Wasser. Neben der Praesentation grundsaetzlicher, moderner Techniken zur Reinhaltung und Aufbereitung von Wasser sowie der Darstellung der gesetzlichen Rahmenbedingungen umspannen die Fachvortraege Beitraege zu den Themen Prozesswasser, Abwasser, Kuehlwasser. Wenn auch die Grenzen innerhalb dieser Begriffe teilweise fliessend sind, so zeichnen sich die Prozesswaesser dadurch aus, dass man primaer - wie beispielsweise bei Waschsloesungen und Beizwaessern - an der Wiedergewinnung der Inhaltsstoffe interessiert ist, waehrend bei reinen Abwaessern und Kuehlturmwaessern bzw. deren Abschlaemmungen die massgebliche Aufgabe darin besteht, die Konzentration der Inhaltsstoffe so weit abzusenken, dass man einerseits den Umwelterfordernissen und andererseits den technischen Qualitaetsanforderungen gerecht wird. Ziel dieses Bandes ist es, an Hand von Grundlagen, der Darstellung der oekologischen und behoerdlichen Erfordernisse sowie ausgewaehlter Fallbeispiele aus der Industrie den Leserkreis naeher an diese Thematik heranzufuehren. (orig.)

  20. Water-cooled radiofrequency neuroablation for sacroiliac joint dysfunctional pain.

    Science.gov (United States)

    Biswas, Binay Kumar; Dey, Samarjit; Biswas, Saumya; Mohan, Varinder Kumar

    2016-01-01

    Sacroiliac (SI) joint dysfunction is a common source of chronic low-back pain. Recent evidences from different parts of the world suggest that cooled radiofrequency (RF) neuroablation of sacral nerves supplying SI joints has superior pain alleviating properties than available existing treatment options for SI joint dysfunctional pain. A 35-year-old male had intractable bilateral SI joint pain (numeric rating scale [NRS] - 9/10) with poor treatment response to intra-articular steroid therapy. Bilateral water cooled = RF was applied for neuroablation of nerves supplying both SI joints. Postprocedure pain intensity was 5/10 and after 7 days it was 2/10. On 18(th)-month follow-up, he is pain free except for mild pain (NRS 2/10) on occasional extreme twisting of the back. This case attempts to highlight that sacral neuroablation based on cooled RF technique can be a long lasting remedial option for chronic SI joint pain unresponsive to conventional treatment.

  1. Water-cooled radiofrequency neuroablation for sacroiliac joint dysfunctional pain

    Directory of Open Access Journals (Sweden)

    Binay Kumar Biswas

    2016-01-01

    Full Text Available Sacroiliac (SI joint dysfunction is a common source of chronic low-back pain. Recent evidences from different parts of the world suggest that cooled radiofrequency (RF neuroablation of sacral nerves supplying SI joints has superior pain alleviating properties than available existing treatment options for SI joint dysfunctional pain. A 35-year-old male had intractable bilateral SI joint pain (numeric rating scale [NRS] - 9/10 with poor treatment response to intra-articular steroid therapy. Bilateral water cooled = RF was applied for neuroablation of nerves supplying both SI joints. Postprocedure pain intensity was 5/10 and after 7 days it was 2/10. On 18th-month follow-up, he is pain free except for mild pain (NRS 2/10 on occasional extreme twisting of the back. This case attempts to highlight that sacral neuroablation based on cooled RF technique can be a long lasting remedial option for chronic SI joint pain unresponsive to conventional treatment.

  2. Water-cooled radiofrequency neuroablation for sacroiliac joint dysfunctional pain

    Science.gov (United States)

    Biswas, Binay Kumar; Dey, Samarjit; Biswas, Saumya; Mohan, Varinder Kumar

    2016-01-01

    Sacroiliac (SI) joint dysfunction is a common source of chronic low-back pain. Recent evidences from different parts of the world suggest that cooled radiofrequency (RF) neuroablation of sacral nerves supplying SI joints has superior pain alleviating properties than available existing treatment options for SI joint dysfunctional pain. A 35-year-old male had intractable bilateral SI joint pain (numeric rating scale [NRS] – 9/10) with poor treatment response to intra-articular steroid therapy. Bilateral water cooled = RF was applied for neuroablation of nerves supplying both SI joints. Postprocedure pain intensity was 5/10 and after 7 days it was 2/10. On 18th-month follow-up, he is pain free except for mild pain (NRS 2/10) on occasional extreme twisting of the back. This case attempts to highlight that sacral neuroablation based on cooled RF technique can be a long lasting remedial option for chronic SI joint pain unresponsive to conventional treatment. PMID:28096589

  3. The physico-chemical treatment of laundry waste water; Tratamiento fisicoquimica de aguas residuales de lavanderias

    Energy Technology Data Exchange (ETDEWEB)

    Susial, P.; Jato, I. G.; Larranaga, I.

    2006-07-01

    Waste water from the washing of clot her is treated with aluminium sulphate + acrylamide to achieve coagulation/flocculation. The analytical data obtained in a jar-test using the FTU as the control parameter demonstrate the efficacy of the process, as reductions in the FTU approaching 100% and elimination rates of 80% in detergents and 85% in the COD were achieved. These results show that coagulation and flocculation are sufficient to treat laundry waste water, even though it contains a high pollutant load, since both organic and inorganic pollutants can be significantly reduced by such operations. (Author) 17 refs.

  4. Effect of Precipitable Water Vapor Amount on Radiative Cooling Performance

    Science.gov (United States)

    Hu, Mingke; Zhao, Bin; Ao, Xianze; Pei, Gang

    2017-05-01

    A radiative cooler based on aluminum-evaporated polyvinyl-fluoride surface was employed to investigate the effect of precipitable water vapor amount on its radiative cooling performance. A mathematic model of steady heat transfer that considers the spectral radiant distribution of the sky, the transparent cover and the collecting surface was established. The results indicate that the amount of precipitable water vapor shows a remarkable and negative effect on radiative cooling performance of the radiative cooler. Both the temperature difference between the cooler and surroundings and the net radiative cooling power decrease as the precipitable water vapor amount increases. The net radiative cooling power drops by about 41.0% as the the precipitable water vapor amount changes from 1.0 cm to 7.0 cm. Besides, the radiative cooler shows better cooling performance in winter than in summer. The net radiative cooling power in summer of Hefei is about 82.2% of that in winter.

  5. Cooling cows efficiently with sprinklers: Physiological responses to water spray.

    Science.gov (United States)

    Chen, Jennifer M; Schütz, Karin E; Tucker, Cassandra B

    2015-10-01

    Dairies in the United States commonly cool cattle with sprinklers mounted over the feed bunk that intermittently spray the cows' backs. These systems use potable water-an increasingly scarce resource--but there is little experimental evidence about how much is needed to cool cows or about droplet size, which is thought to affect hair coat penetration. Our objectives were to determine how sprinkler flow rate and droplet size affect physiological measures of heat load in a hot, dry climate, and to evaluate cooling effectiveness against water use. The treatments were an unsprayed control and 6 soaker nozzles that delivered four 3-min spray applications of 0.4, 1.3, or ≥ 4.5 L/min (with 2 droplet sizes within each flow rate) and resulting in 30 to 47% of spray directly wetting each cow. Data were collected from high-producing lactating Holsteins (n = 19) tested individually in ambient conditions (air temperature = 31.2 ± 3.8°C, mean ± standard deviation). Cows were restrained in headlocks for 1h and received 1 treatment/d for 3d each, with order of exposure balanced in a crossover design. When cows were not sprayed, physiological measures of heat load increased during the 1-h treatment. All measures responded rapidly to spray: skin temperature decreased during the first water application, and respiration rate and body temperature did so before the second. Droplet size had no effect on cooling, but flow rate affected several measures. At the end of 1h, 0.4 L/min resulted in lower respiration rate and skin temperature on directly sprayed body parts relative to the control but not baseline values, and body temperature increased to 0.2°C above baseline. When 1.3 or ≥ 4.5 L/min was applied, respiration rate was lower than the control and decreased relative to baseline, and body temperature stayed below baseline for at least 30 min after treatment ended. The treatment that best balanced cooling effectiveness against water usage was 1.3 L/min: although ≥ 4.5 L

  6. Detailed Design of Cooling Water System for Cold Neutron Source in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Soo; Choi, Jung Woon; Kim, Y. K.; Wu, S. I.; Lee, Y. S

    2007-04-15

    To make cold neutron, a cryogenic refrigerator is necessary to transform moderator into cryogenic state so, thermal neutron is changed into cold neutron through heat transfer with moderator. A cryogenic refrigerator mainly consists of two apparatus, a helium compressor and a cold box which needs supply of cooling water. Therefore, cooling water system is essential to operate of cryogenic refrigerator normally. This report is mainly focused on the detailed design of the cooling water system for the HANARO cold neutron source, and describes design requirement, calculation, specification of equipment and water treatment method.

  7. Detailed Design of Cooling Water System for Cold Neutron Source in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Soo; Choi, Jung Woon; Kim, Y. K.; Wu, S. I.; Lee, Y. S

    2007-04-15

    To make cold neutron, a cryogenic refrigerator is necessary to transform moderator into cryogenic state so, thermal neutron is changed into cold neutron through heat transfer with moderator. A cryogenic refrigerator mainly consists of two apparatus, a helium compressor and a cold box which needs supply of cooling water. Therefore, cooling water system is essential to operate of cryogenic refrigerator normally. This report is mainly focused on the detailed design of the cooling water system for the HANARO cold neutron source, and describes design requirement, calculation, specification of equipment and water treatment method.

  8. Use of nanofiltration to reduce cooling tower water usage.

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Andres L.; Everett, Randy L.; Jensen, Richard Pearson; Cappelle, Malynda A.; Altman, Susan Jeanne

    2010-09-01

    Nanofiltration (NF) can effectively treat cooling-tower water to reduce water consumption and maximize water usage efficiency of thermoelectric power plants. A pilot is being run to verify theoretical calculations. A side stream of water from a 900 gpm cooling tower is being treated by NF with the permeate returning to the cooling tower and the concentrate being discharged. The membrane efficiency is as high as over 50%. Salt rejection ranges from 77-97% with higher rejection for divalent ions. The pilot has demonstrated a reduction of makeup water of almost 20% and a reduction of discharge of over 50%.

  9. Use of nanofiltration to reduce cooling tower water consumption.

    Energy Technology Data Exchange (ETDEWEB)

    Altman, Susan Jeanne; Ciferno, Jared

    2010-10-01

    Nanofiltration (NF) can effectively treat cooling-tower water to reduce water consumption and maximize water usage efficiency of thermoelectric power plants. A pilot is being run to verify theoretical calculations. A side stream of water from a 900 gpm cooling tower is being treated by NF with the permeate returning to the cooling tower and the concentrate being discharged. The membrane efficiency is as high as over 50%. Salt rejection ranges from 77-97% with higher rejection for divalent ions. The pilot has demonstrated a reduction of makeup water of almost 20% and a reduction of discharge of over 50%.

  10. A heat dissipating model for water cooling garments

    Directory of Open Access Journals (Sweden)

    Yang Kai

    2013-01-01

    Full Text Available A water cooling garment is a functional clothing used to dissipate human body’s redundant energy in extravehicular environment or other hot environment. Its heat dissipating property greatly affects body’s heat balance. In this paper, a heat dissipating model for the water cooling garment is established and verified experimentally using the experimental thermal-manikin.

  11. Study on water cooled high conversion reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ochiai, Masaaki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1999-12-01

    As a part of study on advanced reactors for the future, conceptual design of high conversion water cooled reactors is being studied, aiming at the contribution to nuclear fuel cycle by the LWR technology, since the utilization of LWRs will extend over a long period of time . We are studying on the reactor core concepts for BWR and PWR reactor systems. As for BWR system, three types of reactor cores are investigating for three different design goals; long operation period, high conversion ratio and high applicability for the existing BWR system. In all the cases, we have obtained a fair prospect of a large core concept with a capacity of 1,000 MWe class having negative void reactivity coefficient. This study is a part of JAERI-JAPCO (Japan Atomic Power Company) cooperative studies. Various kinds of conceptual designs will be created until the end of FY 1999. The designs will be checked and reviewed at that time, then experimental studies on the realization of the concepts will start with further design works from FY 2000. (author)

  12. Application of Heat Pump in Cooling Water System of HIRFL

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Accelerator generates a lot of heat when it is working.It must be cooled by the circulating cooling water.Generally the heat was released to atimosphere by the cooling water tower.Because the heat energy is very huge(about 2M watts for HIRFL),it is big waste and the machine can’t be cooled to appropriate temperature when ambient temperature is high in summer.In order to solve the problems,the heat pump has been used

  13. Safe corrosion inhibitor for treating cooling water on heat power engineering plants

    Science.gov (United States)

    Nikolaeva, L. A.; Khasanova, D. I.; Mukhutdinova, E. R.; Safin, D. Kh.; Sharifullin, I. G.

    2017-08-01

    Heat power engineering (HPE) consumes significant volumes of water. There are, therefore, problems associated with corrosion, biological fouling, salt deposits, and sludge formation on functional surfaces of heat power equipment. One of the effective ways to solve these problems is the use of inhibitory protection. The development of new Russian import-substituting environmentally friendly inhibitors is very relevant. This work describes experimental results on the OPC-800 inhibitor (TU 2415-092-00206 457-2013), which was produced at Karpov Chemical Plant and designed to remove mineral deposits, scale, and biological fouling from the surfaces of water-rotation node systems on HPE objects. This reagent is successfully used as an effective corrosion inhibitor in the water recycling systems of Tatarstan petrochemical enterprises. To save fresh make-up water, the circulating system is operated in a no-blow mode, which is characterized by high evaporation and salt content coefficients. It was experimentally found that corrosion rate upon treatment of recycled water with the OPC-800 inhibitor is 0.08-0.10 mm/year. HPE mainly uses inhibitors based on oxyethylidene diphosphonic (OEDPA) and nitrilotrimethylphosphonic (NTMPA) acids. The comparative characteristic of inhibition efficiency for OPC-800 and OEDF-Zn-U2 is given. The results obtained indicate that OPC-800 can be used as an inhibitor for treatment of cooling water in HPE plants. In this case, it is necessary to take into account the features of water rotation of a thermal power plant.

  14. In situ polar organic chemical integrative sampling (POCIS) of steroidal estrogens in sewage treatment works discharge and river water.

    Science.gov (United States)

    Rujiralai, Thitima; Bull, Ian D; Llewellyn, Neville; Evershed, Richard P

    2011-05-01

    A passive sampler (the polar organic chemical integrative sampler; POCIS) was assessed for its ability to sample natural estrogens (17β-estradiol, E2; estrone, E1 and estriol, E3) and the synthetic estrogen (17α-ethynylestradiol, EE2) in the outlet of a sewage treatment works over several weeks. The performance of the POCIS was investigated and optimised in the laboratory before field deployment with high recoveries (66-99%) were achieved for all estrogens. Moreover, it was shown that POCIS does not exhibit any preferential selectivity towards any of the target compounds. The sampling rates of E1, E2 and E3 were 0.018 ± 0.009, 0.025 ± 0.014 and 0.033 ± 0.019 L d(-1), respectively. Following field deployments of 28 days in the discharge of a sewage works, POCIS was shown to enhance the sensitivity of estrogen detection, especially for E3, and provide time-weighted average (TWA) concentrations of E1, E2 and E3, ranging from undetectable to 12 ng L(-1) upstream of the outflow of a sewage treatment works, 13 to 91 ng L(-1) at the outflow and 8 to 39 ng L(-1) downstream of the outflow. This revealed that E1, E2 and E3 are not completely removed during sewage treatment, with concentrations most likely being maintained by contributions from conjugated estrogen analogues. Grab water samples showed considerable variation in the concentrations of estrogens over a longer period (6 months). The results confirm that POCIS is an effective and non-discriminatory method for the detection of low concentrations of estrogens in the aquatic environment.

  15. Enhancing the performance of photovoltaic panels by water cooling

    Directory of Open Access Journals (Sweden)

    K.A. Moharram

    2013-12-01

    Full Text Available The objective of the research is to minimize the amount of water and electrical energy needed for cooling of the solar panels, especially in hot arid regions, e.g., desert areas in Egypt. A cooling system has been developed based on water spraying of PV panels. A mathematical model has been used to determine when to start cooling of the PV panels as the temperature of the panels reaches the maximum allowable temperature (MAT. A cooling model has been developed to determine how long it takes to cool down the PV panels to its normal operating temperature, i.e., 35 °C, based on the proposed cooling system. Both models, the heating rate model and the cooling rate model, are validated experimentally. Based on the heating and cooling rate models, it is found that the PV panels yield the highest output energy if cooling of the panels starts when the temperature of the PV panels reaches a maximum allowable temperature (MAT of 45 °C. The MAT is a compromise temperature between the output energy from the PV panels and the energy needed for cooling.

  16. Operations improvement of the recycling water-cooling systems of sugar mills

    Directory of Open Access Journals (Sweden)

    Shcherbakov Vladimir Ivanovich

    Full Text Available Water management in sugar factories doesn’t have analogues in its complexity among food industry enterprises. Water intensity of sugar production is very high. Circulation water, condensed water, pulp press water and others are used in technological processes. Water plays the main role in physical, chemical, thermotechnical processes of beet processing and sugar production. As a consequence of accession of Russia to the WTO the technical requirements for production processes are changing. The enforcements of ecological services to balance scheme of water consumption and water disposal increased. The reduction of fresh water expenditure is one of the main tasks in economy of sugar industry. The substantial role in fresh water expenditure is played by efficiency of cooling and aeration processes of conditionally clean waters of the 1st category. The article contains an observation of the technologies of the available solutions and recommendations for improving and upgrading the existing recycling water-cooling systems of sugar mills. The authors present the block diagram of the water sector of a sugar mill and a method of calculating the optimal constructive and technological parameters of cooling devices. Water cooling towers enhanced design and upgrades are offered.

  17. Electrocoagulation in Water Treatment

    Science.gov (United States)

    Liu, Huijuan; Zhao, Xu; Qu, Jiuhui

    Electrocoagulation (EC) is an electrochemical method of treating polluted water where sacrificial anodes corrode to release active coagulant precursors (usually aluminum or iron cations) into solution. At the cathode, gas evolves (usually as hydrogen bubbles) accompanying electrolytic reactions. EC needs simple equipments and is designable for virtually any size. It is cost effective and easily operable. Specially, the recent technical improvements combined with a growing need for small-scale water treatment facilities have led to a revaluation of EC. In this chapter, the basic principle of EC was introduced first. Following that, reactions at the electrodes and electrode assignment were reviewed; electrode passivation process and activation method were presented; comparison between electrocoagulation and chemical coagulation was performed; typical design of the EC reactors was also described; and factors affecting electrocoagulation including current density, effect of conductivity, temperature, and pH were introduced in details. Finally, application of EC in water treatment was given in details.

  18. Naegleria fowleri in cooling waters of power plants

    Energy Technology Data Exchange (ETDEWEB)

    Cerva, L.; Kasprzak, W.; Mazur, T.

    1982-01-01

    Six strains of nonvirulent and three strains of virulent variants of Naegleria fowleri amoebae were isolated from the examined cooling water samples from 9 power plants. The virulent variants were obtained solely from effluents discharged from power plants with a closed-circuit cooling N. fowleri was not detected outside the reach of the thermal pollution. A disinfection of out-flowing cooling water seems to be an unnecessary investment in our climate. Warm discharge water should under no conditions be used directly for sports and recreational purposes.

  19. Water Treatment Group

    Data.gov (United States)

    Federal Laboratory Consortium — This team researches and designs desalination, water treatment, and wastewater treatment systems. These systems remediate water containing hazardous c hemicals and...

  20. 化学业污水二次处理利用机制分析%Analysis on mechanism of chemical waste water secondary treatment

    Institute of Scientific and Technical Information of China (English)

    沈应栋

    2015-01-01

    文章从化学业污水二次处理的方式出发,总结二次处理的利用机制,对提升水质有一定的帮助。%The mechanism of waste water secondary treatment are presented in this paper in terms of chemical industry to provide reference for understanding of improving water quality.

  1. Corrosion control when using secondary treated municipal wastewater as alternative makeup water for cooling tower systems.

    Science.gov (United States)

    Hsieh, Ming-Kai; Li, Heng; Chien, Shih-Hsiang; Monnell, Jason D; Chowdhury, Indranil; Dzombak, David A; Vidic, Radisav D

    2010-12-01

    Secondary treated municipal wastewater is a promising alternative to fresh water as power plant cooling water system makeup water, especially in arid regions. Laboratory and field testing was conducted in this study to evaluate the corrosiveness of secondary treated municipal wastewater for various metals and metal alloys in cooling systems. Different corrosion control strategies were evaluated based on varied chemical treatment. Orthophosphate, which is abundant in secondary treated municipal wastewater, contributed to more than 80% precipitative removal of phosphorous-based corrosion inhibitors. Tolyltriazole worked effectively to reduce corrosion of copper (greater than 95% inhibition effectiveness). The corrosion rate of mild steel in the presence of free chlorine 1 mg/L (as Cl2) was approximately 50% higher than in the presence of monochloramine 1 mg/L (as Cl2), indicating that monochloramine is a less corrosive biocide than free chlorine. The scaling layers observed on the metal alloys contributed to corrosion inhibition, which could be seen by comparing the mild steel 21-day average corrosion rate with the last 5-day average corrosion rate, the latter being approximately 50% lower than the former.

  2. Cooling of gas turbines IX : cooling effects from use of ceramic coatings on water-cooled turbine blades

    Science.gov (United States)

    Brown, W Byron; Livingood, John N B

    1948-01-01

    The hottest part of a turbine blade is likely to be the trailing portion. When the blades are cooled and when water is used as the coolant, the cooling passages are placed as close as possible to the trailing edge in order to cool this portion. In some cases, however, the trailing portion of the blade is so narrow, for aerodynamic reasons, that water passages cannot be located very near the trailing edge. Because ceramic coatings offer the possibility of protection for the trailing part of such narrow blades, a theoretical study has been made of the cooling effect of a ceramic coating on: (1) the blade-metal temperature when the gas temperature is unchanged, and (2) the gas temperature when the metal temperature is unchanged. Comparison is also made between the changes in the blade or gas temperatures produced by ceramic coatings and the changes produced by moving the cooling passages nearer the trailing edge. This comparison was made to provide a standard for evaluating the gains obtainable with ceramic coatings as compared to those obtainable by constructing the turbine blade in such a manner that water passages could be located very near the trailing edge.

  3. Wastewater Treatment and Its Reuse as Circulating Cooling Water in Coking Plant%焦化厂废水处理及回用于循环冷却水的研究

    Institute of Scientific and Technical Information of China (English)

    宁秀美

    2015-01-01

    以宁夏宝丰能源集团有限公司焦化废水处理及回用为例,说明采用“预处理+强化生物脱氮+深度处理”工艺处理焦化废水,出水达到《城市污水再生利用·工业用水水质》(GB/T19923—2005)敞开式循环冷却水系统补充水水质标准,回用于循环冷却水补充水,实现焦化废水资源化循环利用,节约水资源,保护水环境。%Taking coking wastewater treatment in Ningxia Baofeng Energy Group Co., Ltd as an example, it is proved that"pretreatment plus enhanced biological nitrogen removal plus advanced treatment" could make the wastewater become addi-tional water for the opening circulating cooling water system, which meets the standard of Reuse of Urban Recycling Wa-ter--Water Quality Standard for Industrial Use(GB/T19923-2005). This kind of process can realize coking wastewater recy-cling, save water resource and protect water environment.

  4. CLEAN CHEMICAL SYNTHESIS IN WATER

    Science.gov (United States)

    Newer green chemistry approach to accomplish chemical synthesis in water is summarized. Recent global developments pertaining to C-C bond forming reactions using metallic reagents and direct use of the renewable materials such as carbohydrates without derivatization are described...

  5. Optimization of anti-fouling treatment of water of the circulation circuit (the main condenser cooling)of the Cofrentes nuclear power station; Optimizacion del tratamiento anti-incrustante del circuito de agua de circulacion (refrigeracion del condensador principal) de la central nuclear de Cofrentes

    Energy Technology Data Exchange (ETDEWEB)

    Gomez San Roman, L.; Gomez Larios, J.

    2013-03-01

    The cooling systems is a semi-closed system with natural draft towers and a continued purge to two discharge ponds that store the water before the final discharge to the Jucar river, after having reviewed both chemically and radiologically. The total volume is 75,000 m{sup 3} and flow contribution 3,500-4,000 m{sup 3}/hour, according to the seasons. It aims to minimize the content of sulfates and phosphates in the Jucar river discharge. The new treatment aims to lead the cooling water to a higher pH, decreasing the dosage of sulfuric acid and reducing organic phosphorus compounds of the components involved in the formulation of the antifouling product which is traditionally used. The content of final sulfates and phosphates in the discharge is less than that of a classic anti-fouling and consequently it obtain an environmental improvement in Jucar river discharges. The first pilot plant tests have concluded that we can, raise the average pH of 8.5 a pH average of 8.6 in the recirculating water, representing a decrease of acid consumption of 1,600 to 2,300 kg per day of 98% SO{sub 4}H{sub 2} on a previous consumption of 9,000 kg per day. As to the reduction of phosphate, the new copolymer incorporates a new treatment with a higher concentration of active, it reduces the content of the phosphorus product by 29% and consequently the reduction of phosphorus in water is poured around 20% from the previous treatment. (Author)

  6. Use of reclaimed water for power plant cooling.

    Energy Technology Data Exchange (ETDEWEB)

    Veil, J. A.; Environmental Science Division

    2007-10-16

    Freshwater demands are steadily increasing throughout the United States. As its population increases, more water is needed for domestic use (drinking, cooking, cleaning, etc.) and to supply power and food. In arid parts of the country, existing freshwater supplies are not able to meet the increasing demands for water. New water users are often forced to look to alternative sources of water to meet their needs. Over the past few years, utilities in many locations, including parts of the country not traditionally water-poor (e.g., Georgia, Maryland, Massachusetts, New York, and North Carolina) have needed to reevaluate the availability of water to meet their cooling needs. This trend will only become more extreme with time. Other trends are likely to increase pressure on freshwater supplies, too. For example, as populations increase, they will require more food. This in turn will likely increase demands for water by the agricultural sector. Another example is the recent increased interest in producing biofuels. Additional water will be required to grow more crops to serve as the raw materials for biofuels and to process the raw materials into biofuels. This report provides information about an opportunity to reuse an abundant water source -- treated municipal wastewater, also known as 'reclaimed water' -- for cooling and process water in electric generating facilities. The report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL) Innovations for Existing Plants research program (Feeley 2005). This program initiated an energy-water research effort in 2003 that includes the availability and use of 'nontraditional sources' of water for use at power plants. This report represents a unique reference for information on the use of reclaimed water for power plant cooling. In particular, the database of reclaimed water user facilities described in Chapter 2 is the first comprehensive national effort

  7. Chlorine treatment effectiveness and physico-chemical and bacteriological characteristics of treated water supplies in distribution networks of Accra-Tema Metropolis, Ghana

    Science.gov (United States)

    Karikari, A. Y.; Ampofo, J. A.

    2013-06-01

    Drinking water quality from two major treatment plants in Ghana; Kpong and Weija Plants, and distribution networks in the Accra-Tema Metropolis were monitored monthly for a year at fifteen different locations. The study determined the relationship between chlorine residual, other physico-chemical qualities of the treated water, and, bacteria regrowth. Results indicated that the treated water at the Kpong and Weija Treatment Plants conformed to WHO guidelines for potable water. However, the water quality deteriorated bacteriologically, from the plants to the delivery points with high numbers of indicator and opportunistic pathogens. This could be due to inadequate disinfection residual, biofilms or accidental point source contamination by broken pipes, installation and repair works. The mean turbidity ranged from 1.6 to 2.4 NTU; pH varied from 6.8 to 7.4; conductivity fluctuated from 71.1 to 293 μS/cm. Chlorine residual ranged from 0.13 to 1.35 mg/l. High residual chlorine was observed at the treatment plants, which decreased further from the plants. Results showed that additional chlorination does not take place at the booster stations. Chlorine showed inverse relationship with microbial counts. Total coliform bacteria ranged from 0 to 248 cfu/100 ml, and faecal coliform values varied from 0 to 128 cfu/100 ml. Other microorganisms observed in the treated water included Aeromonas spp., Clostridium spp. and Pseudomonas spp. Boiling water in the household before consumption will reduce water-related health risks.

  8. A data acquisition system for water heating and cooling experiments

    Science.gov (United States)

    Perea Martins, J. E. M.

    2017-01-01

    This work presents a simple analogue waterproof temperature probe design and its electronic interfacing with a computer to compose a data acquisition system for water temperature measurement. It also demonstrates the system usage through an experiment to verify the water heating period with an electric heater and another to verify the Newton’s law of cooling

  9. Conditioning of cooling water in power stations. Feedback from twenty years of experience with acid feeding

    Energy Technology Data Exchange (ETDEWEB)

    Goffin, C.; Duvivier, L.; Girasa, E. [LABORELEC, Chemistry of Water (Belgium); Brognez, J. [ELECTRABEL, TIHANGE Nuclear Power Station (Belgium)

    2002-07-01

    In the late 1970's and early 1980's, with the development of the nuclear programme in many European countries, the recirculation of cooling water in power stations became an issue which required urgent attention. The concentration of several plants of 1000 MW or more on sites along inland waterways actually made simple once-through cooling impossible, owing to the risk of an unacceptable rise in the river's water temperature. The chemical composition of natural freshwater in western European waterways is such that when it becomes slightly concentrated, scale is rapidly formed. The relatively low solubility of calcium carbonate and the degassing of the carbon dioxide during close contact between the water and air in the heat exchangers of the cooling tower explain this precipitation tendency. Fairly soon, experts in the electricity power generation companies highlighted the need for on-site, pilot loop simulations, in order to foresee the physico-chemical phenomena that could arise in industrial installations. The number of financially justifiable processing possibilities could be briefly summarised by the following three solutions: to adapt the concentration factor in order to be under the calcium carbonate solubility limit and thereby avoid the need for any water conditioning; to accept concentration factors of between 1.4 and 1.9 and control the calcium carbonate precipitation through controlled acid injection in the circulation water; to raise the concentration factor over 5 and soften the makeup water through the addition of lime and flocculant. The last of these solutions was rarely ever used in Belgium and France. It was however widely used in Germany. Its application requires a greater investment and leads to higher operating costs than acid injection. Furthermore, it leads to the problem of daily drying and disposal of several dozen tonnes of sludge, which have to be recycled or dumped. In an increasingly stringent environmental context, this

  10. Optimization of Scheme Systems for Recirculated Cooling Water Treatment Processes Applied with Analytic Hierachy Process (AHP)%应用层次分析法(AHP)筛选循环冷却水处理优化方案

    Institute of Scientific and Technical Information of China (English)

    冯长春; 金杰; 朱康生; 高庆华; 陈康; 周国光

    2011-01-01

    该文提出根据循环冷却水的系统情况,运行成本及环境影响等构造层次分析法(AHP)的模型,建立判断矩阵,筛选最优水处理方案,供用户决策使用.AHP的最优水处理配方的筛选系统大大节约了筛选配方所花费的时间及人工费用,加强了水处理系统运行管理的成本控制,为用户提供有效决策管理.%On basis of circulating cooling water system, operation cost and environmental impact and so on, an analytic hierarchy process (AHP) model was constructed, which established judgment matrix and selected the optimal water treatment scheme for users to make decisions. The screening system based on AHP optimal water treatment formula greatly saved time and cost of screening formula, strengthened cost control of operation management, and provided users with effective decision-making management.

  11. Biofouling on Coated Carbon Steel in Cooling Water Cycles Using Brackish Seawater

    Directory of Open Access Journals (Sweden)

    Pauliina Rajala

    2016-11-01

    Full Text Available Water cooling utilizing natural waters is typically used for cooling large industrial facilities such as power plants. The cooling water cycles are susceptible to biofouling and scaling, which may reduce heat transfer capacity and enhance corrosion. The performance of two fouling-release coatings combined with hypochlorite treatment were studied in a power plant utilizing brackish sea water from the Baltic Sea for cooling. The effect of hypochlorite as an antifouling biocide on material performance and species composition of microfouling formed on coated surfaces was studied during the summer and autumn. Microfouling on surfaces of the studied fouling-release coatings was intensive in the cooling water cycle during the warm summer months. As in most cases in a natural water environment the fouling consisted of both inorganic fouling and biofouling. Chlorination decreased the bacterial number on the surfaces by 10–1000 fold, but the efficacy depended on the coating. In addition to decreasing the bacterial number, the chlorination also changed the microbial species composition, forming the biofilm on the surfaces of two fouling-release coatings. TeknoTar coating was proven to be more efficient in combination with the hypochlorite treatment against microfouling under these experimental conditions.

  12. Low temperature heating and high temperature cooling embedded water based surface heating and cooling systems

    CERN Document Server

    Babiak, Jan; Petras, Dusan

    2009-01-01

    This Guidebook describes the systems that use water as heat-carrier and when the heat exchange within the conditioned space is more than 50% radiant. Embedded systems insulated from the main building structure (floor, wall and ceiling) are used in all types of buildings and work with heat carriers at low temperatures for heating and relatively high temperature for cooling.

  13. The Effect of Chemical, Biological and Organic Nutritional Treatments on Sunflowers Yield and Yield Components under the Influence of Water Deficit Stress

    Directory of Open Access Journals (Sweden)

    fatemeh soleymani

    2016-07-01

    Azospirilium lipoferum was impregnated with seeds. Vermicompost was mixed with the soil before planting based on the recommendation of the producer company (15 t.ha-1. After determining evapotranspiration of the reference plant (ET0 by FAO- Penman-Monteith method and crop coefficients (Kc in different stages of crop growth, plant water requirement was determined (Allen et al., 1998. Finally, the irrigation water volume was estimated according to the effective rainfall, irrigation efficiency (60% and 45% depletion of soil moisture in the root zone (Doorenbos & Kassam, 1979. Results and discussion Water deficit stress and nutrient treatments significantly affected all measured traits except the harvest index. Water deficit stress significantly reduced head diameter by 24% in comparison with optimum irrigation. The maximum diameter (17.03 cm was obtained in vermicompost treatment. One thousand seed weight of sunflower under optimum irrigation was 1.3 times as much as water deficit treatment. Combined treatment of vermicompost and half of recommended chemical fertilizer yielded maximum 1000- seed weight (56.67 g. Under optimum irrigation, the highest weight of the head was achieved from 100% chemical fertilizer application, while under water stress, maximum head weight (830.67 g was obtained in vermicompost treatment and the minimum value (485.33 g was obtained from chemical fertilizer + vermicompost + phospho nitro kara. In both irrigation levels, the highest biological yield was obtained from full application of chemical fertilizer, but this treatment in stress condition did not have significant difference with combined application of vermicompost and half of chemical fertilizer, vermicompost and 50% of chemical fertilizer. 100% recommended chemical fertilizer in optimum irrigation, had a maximum grain yield (693.67 g.m-2. Organic fertilizers by increasing soil organic matter, improving soil chemical properties such as pH and CEC, increasing the activity of microorganisms and

  14. Physic-Chemical treatment and demineralization by EDR to reutilize the effluent of an urban waste water treatment plant; Tratamiento fisico-quimico y desmineralizacion por electrodialisis reversible para reutilizar el efluente de una EDAR urbana

    Energy Technology Data Exchange (ETDEWEB)

    Torres Corral, M.; Pino, M.P. del; Gil Lodos, M.; Rodriguez Garcia, M.

    1998-12-01

    Etudes held at the research and development center DEREA placed at Gran Canaria, Canary islands, have proved the viability of regenerating urban waste waters treating the effluent of an urban waste water treatment plant (WWTP del surest) with a physic-chemical treatment followed by a demineralization by electrodialysis reversal. The physic-chemical system was composed of the following units: 1 coagulation tank, 3 floculators, 1 lamellar decanter, 1 pH neutralization system, 1 chlorination system, 1 multi bed filter with chemicals reservoir, dosifiers for lime, FeCl{sub 3} polielectrolytes, sulfuric acid, and NaOCl. The physic-chemical system treated daily about 250-300 cubic meters of the effluents of the EDAR del surest, without chlorination effluent, and worked with a 90% recovery (got 90 m``3 for each 100 feeded). (Author)

  15. Mathematical model and calculation of water-cooling efficiency in a film-filled cooling tower

    Science.gov (United States)

    Laptev, A. G.; Lapteva, E. A.

    2016-10-01

    Different approaches to simulation of momentum, mass, and energy transfer in packed beds are considered. The mathematical model of heat and mass transfer in a wetted packed bed for turbulent gas flow and laminar wave counter flow of the fluid film in sprinkler units of a water-cooling tower is presented. The packed bed is represented as the set of equivalent channels with correction to twisting. The idea put forward by P. Kapitsa on representation of waves on the interphase film surface as elements of the surface roughness in interaction with the gas flow is used. The temperature and moisture content profiles are found from the solution of differential equations of heat and mass transfer written for the equivalent channel with the volume heat and mass source. The equations for calculation of the average coefficients of heat emission and mass exchange in regular and irregular beds with different contact elements, as well as the expression for calculation of the average turbulent exchange coefficient are presented. The given formulas determine these coefficients for the known hydraulic resistance of the packed bed element. The results of solution of the system of equations are presented, and the water temperature profiles are shown for different sprinkler units in industrial water-cooling towers. The comparison with experimental data on thermal efficiency of the cooling tower is made; this allows one to determine the temperature of the cooled water at the output. The technical solutions on increasing the cooling tower performance by equalization of the air velocity profile at the input and creation of an additional phase contact region using irregular elements "Inzhekhim" are considered.

  16. Water-Cooled Components Testing Program. Water-cooled nozzle testing

    Energy Technology Data Exchange (ETDEWEB)

    1985-05-01

    This experimental program involving full-sized gas turbine components was directed towards investigating the nature, composition, and formation rates of the ash deposited on these components by the combustion of hot, minimally cleaned coal gas (MCCG) under actual operating environments. Fired combustion testing was performed using the hot coal gas generated by the fixed-bed coal gasifier in the GE/CRD Process Evaluation Facility (PEF). The hot gas was routed from the gasifier at approx.1000/sup 0/F to a hot cyclone for particulate removal, following which the gas was burned in the turbine simulator, a pressurized test rig. The cyclone was found to have an average particulate removal efficiency of approximately 98%. The concentration of total alkali in the fuel gas entering the turbine simulator was 0.3 to 0.6 ppM, half of which was water-soluble; this corresponds to 1 to 2 ppM in a liquid petroleum-based fuel. The ash content of the fuel gas was 9 to 16 ppM, which would correspond to 51 to 91 ppM of ash in a residual fuel oil, i.e., much lower than that usually found in the latter fuel. Very little ash was found to deposit on the water-cooled nozzle airfoils. Ash deposits on the airfoils were primarily PbSO/sub 4/ and Fe/sub 2/O/sub 3/, which proved to be readily removed by water washing. While the MCCG combustion process was satisfactory, testing indicated that a potential area of concern in burning hot MCCG fuel is the formation of carbonaceous deposits in the fuel nozzle and piping. Variations in operating parameters and procedures may be effective in avoiding such deposits. Test data and analysis thus provided clearer insight into the additional work needed to enable a gas turbine to utilize hot (>1000/sup 0/F), minimally cleaned coal gas fuel. Five problems are described. 5 refs., 82 figs., 26 tabs.

  17. Increasing photovoltaic panel power through water cooling technique

    Directory of Open Access Journals (Sweden)

    Calebe Abrenhosa Matias

    2017-02-01

    Full Text Available This paper presents the development of a cooling apparatus using water in a commercial photovoltaic panel in order to analyze the increased efficiency through decreased operating temperature. The system enables the application of reuse water flow, at ambient temperature, on the front surface of PV panel and is composed of an inclined plane support, a perforated aluminum profile and a water gutter. A luminaire was specially developed to simulate the solar radiation over the module under test in a closed room, free from the influence of external climatic conditions, to carry out the repetition of the experiment in controlled situations. The panel was submitted to different rates of water flow. The best water flow rate was of 0.6 L/min and net energy of 77.41Wh. Gain of 22.69% compared to the panel without the cooling system.

  18. Guided design of heating and cooling mains for lower water and energy consumption and increased efficiency

    CSIR Research Space (South Africa)

    Gololo, V

    2011-01-01

    Full Text Available in higher cooling water flowrate and low cooling water return temperature thus reducing cooling towers efficiency. This indicates the importance of the system structure, the possibility of mixing of heating or cooling water; recycling and reuse of heating...

  19. Cool Stars May Have Different Prebiotic Chemical Mix

    Science.gov (United States)

    2009-01-01

    NASA's Spitzer Space Telescope detected a prebiotic, or potentially life-forming, molecule called hydrogen cyanide (HCN) in the planet-forming disks around yellow stars like our sun, but not in the disks around cooler, reddish stars. The observations are plotted in this graph, called a spectrum, in which light from the gas in the disks around the stars has been split up into its basic components, or wavelengths. Data from stars like our sun are yellow, and data from cool stars are orange. Light wavelengths are shown on the X-axis, and the relative brightness of disk emission is shown on the Y-axis. The signature of a baseline molecule, called acetylene (C2H2), was seen for both types of stars, but hydrogen cyanide was seen only around stars like our sun. Hydrogen cyanide is an organic, nitrogen-containing molecule. Five hydrogen cyanide molecules can link up to form adenine, one of the four chemical bases of DNA.

  20. Geographic, technologic, and economic analysis of using reclaimed water for thermoelectric power plant cooling.

    Science.gov (United States)

    Stillwell, Ashlynn S; Webber, Michael E

    2014-04-15

    Use of reclaimed water-municipal wastewater treatment plant effluent-in nonpotable applications can be a sustainable and efficient water management strategy. One such nonpotable application is at thermoelectric power plants since these facilities require cooling, often using large volumes of freshwater. To evaluate the geographic, technologic, and economic feasibility of using reclaimed water to cool thermoelectric power plants, we developed a spatially resolved model of existing power plants. Our model integrates data on power plant and municipal wastewater treatment plant operations into a combined geographic information systems and optimization approach to evaluate the feasibility of cooling system retrofits. We applied this broadly applicable methodology to 125 power plants in Texas as a test case. Results show that sufficient reclaimed water resources exist within 25 miles of 92 power plants (representing 61% of capacity and 50% of generation in our sample), with most of these facilities meeting both short-term and long-term water conservation cost goals. This retrofit analysis indicates that reclaimed water could be a suitable cooling water source for thermoelectric power plants, thereby mitigating some of the freshwater impacts of electricity generation.

  1. Wetland Water Cooling Partnership: The Use of Constructed Wetlands to Enhance Thermoelectric Power Plant Cooling and Mitigate the Demand of Surface Water Use

    Energy Technology Data Exchange (ETDEWEB)

    Apfelbaum, Steven; Duvall, Kenneth; Nelson, Theresa; Mensing, Douglas; Bengtson, Harlan; Eppich, John; Penhallegon, Clayton; Thompson, Ry

    2013-09-30

    ancillary socio-economic, ecosystem, and water treatment/polishing benefits when used to complement water resources at thermoelectric power plants. Through the Phase II pilot study segment of the contract, the project team partnered with Progress Energy Florida (now Duke Energy Florida) to quantify the wetland water cooling benefits at their Hines Energy Complex in Bartow, Florida. The project was designed to test the wetland’s ability to cool and cleanse power plant cooling pond water while providing wildlife habitat and water harvesting benefits. Data collected during the monitoring period was used to calibrate a STELLA model developed for the site. It was also used to inform management recommendations for the demonstration site, and to provide guidance on the use of cooling wetlands for other power plants around the country. As a part of the pilot study, Duke Energy is scaling up the demonstration project to a larger, commercial scale wetland instrumented with monitoring equipment. Construction is expected to be finalized in early 2014.

  2. A case study for orphaned chemicals: 4-methylcyclohexanemethanol (MCHM) and propylene glycol phenyl ether (PPH) in riverine sediment and water treatment processes.

    Science.gov (United States)

    Weidhaas, Jennifer; Lin, Lian-Shin; Buzby, Karen

    2017-01-01

    There are an estimated 30,000 chemicals in commerce used in quantities >1016kg per year in the US. Unfortunately there is limited information on the chemicals partitioning and reactivity properties. These orphaned or understudied chemicals are viewed as non-hazardous but can still pose serious economic, health, environmental and societal impacts as evidenced by the January 2014 spill of 37,900L of crude-MCHM (primarily 4-methylcyclohexanemethanol) and stripped-PPH (primarily dipropylene glycol phenyl ether and propylene glycol phenyl ether) into the Elk River near Charleston, WV. Using the Elk River spill as a case study of orphaned or understudied chemicals, experiments were undertaken to evaluate the adequacy of standard approaches to emergency drinking water treatment (oxidation and sorption to activated carbons). Further available sorption models for estimating the potential of these compounds to sorb to Elk River sediments and to activated carbons in drinking water systems were investigated. The results showed that powdered activated carbon (PAC) was the most effective sorbent. The trans-MCHM isomer was found to preferentially sorb compared to cis-MCHM. For MCHM concentrations ranging from 2 to 5mgL(-1) in the treatment plant, PAC concentrations of 0.1-1.4mgL(-1) would be required to lower both MCHM isomers to the CDC screening level. In most cases, published linear solvation energy relationships and quantitative structure activity relationships were inadequate to estimate the a priori likelihood of sorption of MCHM and PPH to sediments and GAC, but did fit the PAC results well. Permanganate and chlorine oxidation of the compounds showed limited to insignificant removal. The studies presented herein suggest that there are still inherent vulnerabilities to drinking water treatment systems that need to be addressed.

  3. Complex cooling water systems optimization with pressure drop consideration

    CSIR Research Space (South Africa)

    Gololo, KV

    2012-12-01

    Full Text Available Pressure drop consideration has shown to be an essential requirement for the synthesis of a cooling water network where reuse/recycle philosophy is employed. This is due to an increased network pressure drop associated with additional reuse...

  4. Computational Simulation of a Water-Cooled Heat Pump

    Science.gov (United States)

    Bozarth, Duane

    2008-01-01

    A Fortran-language computer program for simulating the operation of a water-cooled vapor-compression heat pump in any orientation with respect to gravity has been developed by modifying a prior general-purpose heat-pump design code used at Oak Ridge National Laboratory (ORNL).

  5. Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings

    DEFF Research Database (Denmark)

    Fang, Lei; Yuan, Shu; Yang, Jianrong

    2016-01-01

    This paper presents a simple cooling technology using flash water evaporation. The technology combines a water atomizer with a plate heat exchanger used for heat recovery of a ventilation system. It is mainly used to cool the ventilation airflow from outdoors and is particularly suitable to be used...... in warm/hot and dry environment where dehumidification of outdoor air is not needed. A laboratory experiment was designed and conducted to evaluate the cooling effectiveness of this technology. The experiment was conducted in a twin-climate chamber. One chamber simulated warm/hot and dry outdoor...... environments and the other simulated an air-conditioned indoor environment. The flash water evaporation cooling device was installed in the chamber that simulated indoor environment. The air from the chamber simulating outdoor environment was introduced into the cooling device and cooled by the flash water...

  6. Presence of pathogenic amoebae in power plant cooling waters. Final report, October 15, 1977-September 30, 1979. [Naegleria fowleri

    Energy Technology Data Exchange (ETDEWEB)

    Tyndall, R.L.; Willaert, E.; Stevens, A.R.

    1981-03-01

    Cooling-water-associated algae and sediments from five northern and five southern or western electric power plants were tested for the presence of pathogenic amoebae. In addition, water algae and sediments from five northern and five southern/western sites not associated with power plants were tested. There was a significant correlation at northern power plants between the presence of thermophilic, pathogenic amoebae in cooling waters and thermal additions. Presence of the pathogenic did not correlate with salinity, pH, conductivity, or a variety of various chemical components of the cooling waters. Selected pathogenic isolates were tested serologically and were classified as Naegleria fowleri. Although thermal additions were shown to be contributing factor in predisposing cooling waters to the growth of pathogenic amoebae, the data suggest the involvement of other currently undefined parameters associated with the presence of the pathogenic amoebae. 35 refs., 21 tabs.

  7. Year-long evaluation on the occurrence and fate of pharmaceuticals, personal care products, and endocrine disrupting chemicals in an urban drinking water treatment plant.

    Science.gov (United States)

    Padhye, Lokesh P; Yao, Hong; Kung'u, Francis T; Huang, Ching-Hua

    2014-03-15

    The occurrence and removal of thirty representative pharmaceutical and personal care products (PPCPs) and endocrine disrupting chemicals (EDCs) in an urban drinking water treatment plant (DWTP) were investigated for a period of one year to evaluate current system's treatment efficacy and assess occurrence of PPCPs and EDCs in finished drinking water. Results showed that the average total PPCPs and EDCs concentration in the surface water source was around 360 ng/L (median concentration = 340 ng/L) with 57% coefficient of variation (CV). The median concentrations of most of the individual PPCPs and EDCs in the surface water were below 15 ng/L except for N,N-diethyltoluamide (DEET) and nonylphenol, which were at 122 and 83 ng/L, respectively. The compounds DEET, nonylphenol, ibuprofen, triclosan, atrazine, tris(2-chloroethyl)-phosphate (TCEP), bisphenol-A, and caffeine (in the order of decreasing median concentration) were among twenty compounds detected at least once in the surface water, while all of the above detected compounds, except two, were also detected in the finished drinking water. The average total PPCPs and EDCs concentration in the finished drinking water was around 98 ng/L (median concentration = 96 ng/L) with 66% CV. The median concentrations of most detected PPCPs and EDCs in drinking water were below 5 ng/L except for DEET and nonylphenol, which were at 12 and 20 ng/L, respectively. There was a strong correlation (r = 0.97) between PPCPs and EDCs' concentrations in the source water and in the drinking water over the one-year study period when data points from two sampling events with unusual removals were excluded. Individual water treatment unit processes showed greater temporal variations of PPCPs and EDCs removal efficiencies than the overall treatment processes. The removal efficiencies also varied greatly among different PPCPs and EDCs. The average removal for total PPCPs and EDCs was 76 ± 18% at the DWTP, with ozonation

  8. Alternative disinfectant water treatments

    Science.gov (United States)

    Alternative disinfestant water treatments are disinfestants not as commonly used by the horticultural industry. Chlorine products that produce hypochlorous acid are the main disinfestants used for treating irrigation water. Chlorine dioxide will be the primary disinfestant discussed as an alternativ...

  9. WRI 50: Strategies for Cooling Electric Generating Facilities Utilizing Mine Water

    Energy Technology Data Exchange (ETDEWEB)

    Joseph J. Donovan; Brenden Duffy; Bruce R. Leavitt; James Stiles; Tamara Vandivort; Paul Ziemkiewicz

    2004-11-01

    Power generation and water consumption are inextricably linked. Because of this relationship DOE/NETL has funded a competitive research and development initiative to address this relationship. This report is part of that initiative and is in response to DOE/NETL solicitation DE-PS26-03NT41719-0. Thermal electric power generation requires large volumes of water to cool spent steam at the end of the turbine cycle. The required volumes are such that new plant siting is increasingly dependent on the availability of cooling circuit water. Even in the eastern U.S., large rivers such as the Monongahela may no longer be able to support additional, large power stations due to subscription of flow to existing plants, industrial, municipal and navigational requirements. Earlier studies conducted by West Virginia University (WV 132, WV 173 phase I, WV 173 Phase II, WV 173 Phase III, and WV 173 Phase IV in review) have identified that a large potential water resource resides in flooded, abandoned coal mines in the Pittsburgh Coal Basin, and likely elsewhere in the region and nation. This study evaluates the technical and economic potential of the Pittsburgh Coal Basin water source to supply new power plants with cooling water. Two approaches for supplying new power plants were evaluated. Type A employs mine water in conventional, evaporative cooling towers. Type B utilizes earth-coupled cooling with flooded underground mines as the principal heat sink for the power plant reject heat load. Existing mine discharges in the Pittsburgh Coal Basin were evaluated for flow and water quality. Based on this analysis, eight sites were identified where mine water could supply cooling water to a power plant. Three of these sites were employed for pre-engineering design and cost analysis of a Type A water supply system, including mine water collection, treatment, and delivery. This method was also applied to a ''base case'' river-source power plant, for comparison. Mine-water

  10. Chemical contamination of water supplies

    Energy Technology Data Exchange (ETDEWEB)

    Shy, C.M.

    1985-10-01

    Man-made organic chemicals have been found in drinking water for many years. Their numbers and varieties increase as our analytical capabilities improve. The identified chemicals comprise 10 to 20% of the total organic matter present. These are volatile or low molecular weight compounds which are easily identified. Many of them are carcinogenic or mutagenic. Chlorinated compounds have been found in untreated well water at levels up to 21,300 micrograms/L and are generally present at higher levels in chlorine-treated water than in untreated water. Aggregate risk studies for cancer are summarized. The most common sites are: bladder, stomach, colon, and rectum. Such studies cannot be linked to individual cases. However, they are useful for identifying exposed populations for epidemiologic studies. Five case-control studies were reviewed, and significant associations with water quality were found for: bladder cancer in two studies, colon cancer in three and rectal cancer in four. A large study by the National Cancer Institute found that there had been a change in the source of raw water for 50% of the persons in one area between the years 1955 and 1975. Such flaws in the data may preclude finding a causal relation between cancer and contaminants in drinking water. Large case-control and cohort studies are needed because of the low frequency of the marker diseases, bladder and rectal cancer. Cohort studies may be precluded by variations in the kinds of water contaminants. Definitive questions about these issues are posed for cooperative effort and resolution by water chemists, engineers, and epidemiologists.

  11. Modeling and energy simulation of the variable refrigerant flow air conditioning system with water-cooled condenser under cooling conditions

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yueming; Wu, Jingyi [Shanghai Jiao Tong University, Institute of Refrigeration and Cryogenics (China); Shiochi, Sumio [Daikin Industries Ltd. (Japan)

    2009-09-15

    As a new system, variable refrigerant flow system with water-cooled condenser (water-cooled VRF) can offer several interesting characteristics for potential users. However, at present, its dynamic simulation simultaneously in association with building and other equipments is not yet included in the energy simulation programs. Based on the EnergyPlus's codes, and using manufacturer's performance parameters and data, the special simulation module for water-cooled VRF is developed and embedded in the software of EnergyPlus. After modeling and testing the new module, on the basis of a typical office building in Shanghai with water-cooled VRF system, the monthly and seasonal cooling energy consumption and the breakdown of the total power consumption are analyzed. The simulation results show that, during the whole cooling period, the fan-coil plus fresh air (FPFA) system consumes about 20% more power than the water-cooled VRF system does. The power comparison between the water-cooled VRF system and the air-cooled VRF system is performed too. All of these can provide designers some ideas to analyze the energy features of this new system and then to determine a better scheme of the air conditioning system. (author)

  12. Endocrine active chemicals, pharmaceuticals, and other chemicals of concern in surface water, wastewater-treatment plant effluent, and bed sediment, and biological characteristics in selected streams, Minnesota-design, methods, and data, 2009

    Science.gov (United States)

    Lee, Kathy E.; Langer, Susan K.; Barber, Larry B.; Writer, Jeff H.; Ferrey, Mark L.; Schoenfuss, Heiko L.; Furlong, Edward T.; Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Martinovic, Dalma; Woodruff, Olivia R.; Keefe, Steffanie H.; Brown, Greg K.; Taylor, Howard E.; Ferrer, Imma; Thurman, E. Michael

    2011-01-01

    This report presents the study design, environmental data, and quality-assurance data for an integrated chemical and biological study of selected streams or lakes that receive wastewater-treatment plant effluent in Minnesota. This study was a cooperative effort of the U.S. Geological Survey, the Minnesota Pollution Control Agency, St. Cloud State University, the University of St. Thomas, and the University of Colorado. The objective of the study was to identify distribution patterns of endocrine active chemicals, pharmaceuticals, and other organic and inorganic chemicals of concern indicative of wastewater effluent, and to identify biological characteristics of estrogenicity and fish responses in the same streams. The U.S. Geological Survey collected and analyzed water, bed-sediment, and quality-assurance samples, and measured or recorded streamflow once at each sampling location from September through November 2009. Sampling locations included surface water and wastewater-treatment plant effluent. Twenty-five wastewater-treatment plants were selected to include continuous flow and periodic release facilities with differing processing steps (activated sludge or trickling filters) and plant design flows ranging from 0.002 to 10.9 cubic meters per second (0.04 to 251 million gallons per day) throughout Minnesota in varying land-use settings. Water samples were collected from the treated effluent of the 25 wastewater-treatment plants and at one point upstream from and one point downstream from wastewater-treatment plant effluent discharges. Bed-sediment samples also were collected at each of the stream or lake locations. Water samples were analyzed for major ions, nutrients, trace elements, pharmaceuticals, phytoestrogens and pharmaceuticals, alkylphenols and other neutral organic chemicals, carboxylic acids, and steroidal hormones. A subset (25 samples) of the bed-sediment samples were analyzed for carbon, wastewater-indicator chemicals, and steroidal hormones; the

  13. Water-cooled radiofrequency neuroablation for sacroiliac joint dysfunctional pain

    OpenAIRE

    2016-01-01

    Sacroiliac (SI) joint dysfunction is a common source of chronic low-back pain. Recent evidences from different parts of the world suggest that cooled radiofrequency (RF) neuroablation of sacral nerves supplying SI joints has superior pain alleviating properties than available existing treatment options for SI joint dysfunctional pain. A 35-year-old male had intractable bilateral SI joint pain (numeric rating scale [NRS] - 9/10) with poor treatment response to intra-articular steroid therapy. ...

  14. Treatment of waste water from recirculating cooling system in LNG plant using electrodialysis technology%电渗析技术处理 LN G 工厂循环冷却系统排污水研究

    Institute of Scientific and Technical Information of China (English)

    王丹; 童富良; 王滟; 杨晓娇

    2014-01-01

    waste water from recirculating cooling system in Hubei LNG plant amounts up to 1 200 m3 per day .Direct discharge would not only cause the waste of water resource ,but also bring large impact to the operation of the downstream sewage treatment plants .In order to pro‐mote the recycling rate ,a “multi‐stage continuous electrodialysis desalination system” was de‐signed to treat the waste water for reusing .According to the design calculation ,the flow veloci‐ty ,the overall desalination rate ,the conductivity of the treated water were set at 5 .0 cm/s ,75%~80% ,and 300~350 μs/cm respectively in 50 m3/h electrodialysis system .The debugging re‐sults showed that the optimum operating voltage was 110 V ,the most suitable flow rate was 50 m3/h ,and the treated water from the electrodialysis system could meet all the design require‐ments .The process can reduce the fresh water consumption and waste water discharge by 300 000 tons per year respectively ,and bring direct economic benefit of about RMB 600 000 yuan each year .%湖北L N G工厂循环冷却水系统每日排污量高达1200 m3,直接排放不仅造成水资源的浪费,同时对下游污水处理厂的运行产生较大冲击。为提高该部分废水的重复利用率,设计采用“多级连续式电渗析除盐系统”对其进行脱盐处理后回用于循环水系统。经计算,50 m3/h的电渗析装置设计流速采用 V =5.0 cm/s ,设计总脱盐率ε=75%~80%,产水电导率300~350μs/cm。装置建成后调试结果表明,最佳操作电压为110 V ,最适宜进水流量为50 m3/h ,产水各项指标满足预期设计要求。每年可减少新鲜水消耗和废水排放各30×104 t ,产生直接经济效益约60万元。

  15. Use of Produced Water in Recirculated Cooling Systems at Power Generating Facilities

    Energy Technology Data Exchange (ETDEWEB)

    C. McGowin; M. DiFilippo; L. Weintraub

    2006-06-30

    Tree ring studies indicate that, for the greater part of the last three decades, New Mexico has been relatively 'wet' compared to the long-term historical norm. However, during the last several years, New Mexico has experienced a severe drought. Some researchers are predicting a return of very dry weather over the next 30 to 40 years. Concern over the drought has spurred interest in evaluating the use of otherwise unusable saline waters to supplement current fresh water supplies for power plant operation and cooling and other uses. The U.S. Department of Energy's National Energy Technology Laboratory sponsored three related assessments of water supplies in the San Juan Basin area of the four-corner intersection of Utah, Colorado, Arizona, and New Mexico. These were (1) an assessment of using water produced with oil and gas as a supplemental supply for the San Juan Generating Station (SJGS); (2) a field evaluation of the wet-surface air cooling (WSAC) system at SJGS; and (3) the development of a ZeroNet systems analysis module and an application of the Watershed Risk Management Framework (WARMF) to evaluate a range of water shortage management plans. The study of the possible use of produced water at SJGS showed that produce water must be treated to justify its use in any reasonable quantity at SJGS. The study identified produced water volume and quality, the infrastructure needed to deliver it to SJGS, treatment requirements, and delivery and treatment economics. A number of produced water treatment alternatives that use off-the-shelf technology were evaluated along with the equipment needed for water treatment at SJGS. Wet surface air-cooling (WSAC) technology was tested at the San Juan Generating Station (SJGS) to determine its capacity to cool power plant circulating water using degraded water. WSAC is a commercial cooling technology and has been used for many years to cool and/or condense process fluids. The purpose of the pilot test was to

  16. The therapeutic use of localized cooling in the treatment of VX poisoning.

    Science.gov (United States)

    Sawyer, T W; Mikler, J; Worek, F; Reiter, G; Thiermann, H; Tenn, C; Weatherby, K; Bohnert, S

    2011-07-04

    The organophosphate (OP) nerve agent VX is a weaponized chemical warfare agent that has also been used by terrorists against civilians. This contact poison produces characteristic signs of OP poisoning, including miosis, salivation, mastication, dysrhythmias and respiratory distress prior to death. Although successful treatment of OP poisoning can be obtained through decontamination and/or oxime reactivation of agent-inhibited cholinesterase, medical countermeasures that increase the therapeutic window for these measures would be of benefit. An anaesthetized swine model was utilized to examine the effects of lethal VX exposure to the skin, followed by cooling the exposure site prior to decontamination or treatment. The cooling was simply accomplished by using crushed ice in grip-seal plastic bags applied to the exposure sites. Cooling of skin exposed to lethal doses of VX significantly increased the window of opportunity for successful decontamination using the Reactive Skin Decontaminant Lotion(®) (RSDL(®)) or treatment with the oxime antidotes HI-6 and 2PAM. Analyses of blood VX levels showed that cooling acted to slow or prevent the entry of VX into the bloodstream from the skin. If the exposure site is known, the simple and non-invasive application of cooling provides a safe means with which to dramatically increase the therapeutic window in which decontamination and/or antidote treatment against VX are life-saving.

  17. Evaluating the polar organic chemical integrative sampler for the monitoring of beta-blockers and hormones in wastewater treatment plant effluents and receiving surface waters.

    Science.gov (United States)

    Jacquet, Romain; Miège, Cécile; Bados, Philippe; Schiavone, Séverine; Coquery, Marina

    2012-02-01

    Wastewater treatment plants (WWTP) are known to be a source of surface water contamination by organic compounds such as pharmaceuticals. The objective of the present work was to study the suitability of the polar organic chemical integrative sampler (POCIS) to monitor beta-blockers and hormones in effluents and surface waters. Four sampling campaigns were carried out in French rivers (the Saône, the Ardières, the Bourbre, and the Seine) between November 2007 and September 2008. Passive samplers were exposed in surface waters, upstream and downstream of WWTP outflows, and in effluents. Exposures lasted for up to 24 d to study the uptake kinetics directly in situ, and repeatability was assessed by exposure of triplicates. A good agreement was found between POCIS and water samples. With the exception of atenolol, beta-blockers showed a linear uptake during at least three weeks, and their sampling rates could be determined in situ. These sampling rates were then used to calculate time-weighted average concentrations of beta-blockers in the Seine River with an overall good accuracy and repeatability. Such calculations could not be performed for hormones because of their variable occurrences and low concentrations in water and POCIS. Polar organic chemical integrative sampler therefore seems to be a suitable tool for monitoring beta-blockers in surface waters impacted by WWTP effluents. Longer exposure durations would be necessary to determine the suitability of POCIS for monitoring hormones. Finally, preliminary assays on the use of several deuterated compounds as performance reference compounds showed promising results for deuterated atenolol. Copyright © 2011 SETAC.

  18. Effect of cooling water on stability of NLC linac components

    Energy Technology Data Exchange (ETDEWEB)

    F. Le Pimpec et al.

    2003-02-11

    Vertical vibration of linac components (accelerating structures, girders and quadrupoles) in the NLC has been studied experimentally and analytically. Effects such as structural resonances and vibration caused by cooling water both in accelerating structures and quadrupoles have been considered. Experimental data has been compared with analytical predictions and simulations using ANSYS. A design, incorporating the proper decoupling of structure vibrations from the linac quadrupoles, is being pursued.

  19. Experimental Studies of NGNP Reactor Cavity Cooling System With Water

    Energy Technology Data Exchange (ETDEWEB)

    Corradini, Michael; Anderson, Mark; Hassan, Yassin; Tokuhiro, Akira

    2013-01-16

    This project will investigate the flow behavior that can occur in the reactor cavity cooling system (RCCS) with water coolant under the passive cooling-mode of operation. The team will conduct separate-effects tests and develop associated scaling analyses, and provide system-level phenomenological and computational models that describe key flow phenomena during RCCS operation, from forced to natural circulation, single-phase flow and two-phase flow and flashing. The project consists of the following tasks: Task 1. Conduct separate-effects, single-phase flow experiments and develop scaling analyses for comparison to system-level computational modeling for the RCCS standpipe design. A transition from forced to natural convection cooling occurs in the standpipe under accident conditions. These tests will measure global flow behavior and local flow velocities, as well as develop instrumentation for use in larger scale tests, thereby providing proper flow distribution among standpipes for decay heat removal. Task 2. Conduct separate-effects experiments for the RCCS standpipe design as two-phase flashing occurs and flow develops. As natural circulation cooling continues without an ultimate heat sink, water within the system will heat to temperatures approaching saturation , at which point two-phase flashing and flow will begin. The focus is to develop a phenomenological model from these tests that will describe the flashing and flow stability phenomena. In addition, one could determine the efficiency of phase separation in the RCCS storage tank as the two-phase flashing phenomena ensues and the storage tank vents the steam produced. Task 3. Develop a system-level computational model that will describe the overall RCCS behavior as it transitions from forced flow to natural circulation and eventual two-phase flow in the passive cooling-mode of operation. This modeling can then be used to test the phenomenological models developed as a function of scale.

  20. DEVELOPMENT OF SINGLE-PHASED WATER-COOLING RADIATOR FOR COMPUTER CHIP

    Institute of Scientific and Technical Information of China (English)

    ZENG Ping; CHENG Guangming; LIU Jiulong; YANG Zhigang; SUN Xiaofeng; PENG Taijiang

    2007-01-01

    In order to cool computer chip efficiently with the least noise, a single phase water-cooling radiator for computer chip driven by piezoelectric pump with two parallel-connection chambers is developed. The structure and work principle of this radiator is described. Material, processing method and design principles of whole radiator are also explained. Finite element analysis (FEA) software,ANSYS, is used to simulate the heat distribution in the radiator. Testing equipments for water-cooling radiator are also listed. By experimental tests, influences of flowrate inside the cooling system and fan on chip cooling are explicated. This water-cooling radiator is proved more efficient than current air-cooling radiator with comparison experiments. During cooling the heater which simulates the working of computer chip with different power, the water-cooling radiator needs shorter time to reach lower steady temperatures than current air-cooling radiator.

  1. Investigation of the Use of Absorption Cooling Cycles to Reduce the Amount of Cooling Water Needed for Power Plants.

    Energy Technology Data Exchange (ETDEWEB)

    Middleton, Bobby D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    This report outlines a preliminary study on the feasibility of using absorption cooling technology to cool thermoelectric power plants. Water availability is becoming more important in the production of energy throughout the world, especially in thermoelectric power generation. Currently, thermoelectric power generation accounts for about 48% of all water withdrawals in the United States. Rising population, increasing e lectricity use per capita, and decreasing water reserves threaten the availability of water for use in cooling power plants. To this end, Sandia National Laboratories has begun an initiative to find ways to increase the water use efficiency of power plants . In 2016, the New Mexico Small Business Association funded a project whereby Sandia would complete a preliminary assessment of the viability of utilizing absorption cooling technologies to aid in cooling thermoelectric power plants, thereby decreasing the amount of water required to generate electricity. This project was proposed by Thales Energy, a small business located in Albuquerque, NM. Due to time and money constraints, only a preliminary analysis was performed. The results indicate that the use of a bsorption cooling technologies is scientifically feasible and that, with more engineering analysis, may be economically feasible for some power plants, dependent upon local environmental conditions and the price currently being paid for cooling water by th e plant.

  2. Research and the Application of Water Reuse Recycle Cooling Water System%中水回用循环冷却水系统研究及现场应用

    Institute of Scientific and Technical Information of China (English)

    张少松; 曹培宽; 白小明

    2012-01-01

    The paper studied the water treatment chemicals that were successfully used in the cycle cooling water system. Recycled water was used in the cycle cooling water system as supplement water in this system, and examined the site operation in a thermo electron corporation of Tianjin economic development zone. In addition, the performance factors were analyzed of cycle cooling water system. Practice had proved that recycled water as supplement water for the circulating water system was successful about 5 years.%针对滨海新区中水水质,研究了适应天津经济技术开发区某热电公司应用的中水水质、系统材质和工况条件的水处理药剂及其配套高浓缩倍率水处理技术,并应用于现场运行控制。通过对近五年现场应用结果进行深入总结分析,说明中水回用于循环水系统处理技术是成功的,取得明显的经济效益和社会效益。

  3. 77 FR 36014 - Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors

    Science.gov (United States)

    2012-06-15

    ... COMMISSION Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors AGENCY: Nuclear...-1277, ``Initial Test Program of Emergency Core Cooling Systems for Boiling- Water Reactors.'' This... testing features of emergency core cooling systems (ECCSs) for boiling-water reactors (BWRs). DATES...

  4. 78 FR 35330 - Initial Test Programs for Water-Cooled Nuclear Power Plants

    Science.gov (United States)

    2013-06-12

    ... COMMISSION Initial Test Programs for Water-Cooled Nuclear Power Plants AGENCY: Nuclear Regulatory Commission... revision to Regulatory Guide (RG), 1.68, ``Initial Test Programs for Water-Cooled Nuclear Power Plants... Initial Test Programs (ITPs) for light water cooled nuclear power plants. ADDRESSES: Please refer...

  5. Experimental validation of the simulation module of the water-cooled variable refrigerant flow system under cooling operation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yue Ming; Wu, Jing Yi [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai (China); Shiochi, Sumio [Daikin Industries, Ltd., 1304 Kanaoka-cho, Kita-ku, Sakai, Osaka 591-8511 (Japan)

    2010-05-15

    On the basis of EnergyPlus's codes, the catalogue and performance parameters from some related companies, a special simulation module for variable refrigerant flow system with a water-cooled condenser (water-cooled VRF) was developed and embedded in the software of EnergyPlus, the building energy simulation program. To evaluate the energy performance of the system and the accuracy of the simulation module, the measurement of the water-cooled VRF is built in Dalian, China. After simulation and comparison, some conclusions can be drawn. The mean of the absolute value of the daily error in the 9 days is 11.3% for cooling capacity while the one for compressor power is 15.7%. At the same time, the accuracy of the power simulation strongly depends on the accuracy of the cooling capacity simulation. (author)

  6. Behavior of Aluminum Based Coagulants in Treatment of Surface Water–Assessment of Chemical and Microbiological Properties of Treated Water

    Directory of Open Access Journals (Sweden)

    Spînu (Gologan Daniela

    2014-03-01

    Full Text Available Pre-polymerized inorganic aluminum coagulants have high efficiency in reducing turbidity, total, dissolved, biodegradable organic carbon and microbiological content of surface waters used for drinking, while obtaining low concentrations of residual aluminum after the coagulation phase. Correlation between turbidity raw water and coagulant dose is logarithmic being influenced by temperature and organic content of surface waters. The coagulant’s effect on the organic content of the raw water is closely related to the microbiological concentration and can thus determine the mathematical correlations between the two types of parameters after the coagulation-flocculation stage that can be used to assess the water biostability coagulant action.

  7. High Throughput Plasma Water Treatment

    Science.gov (United States)

    Mujovic, Selman; Foster, John

    2016-10-01

    The troublesome emergence of new classes of micro-pollutants, such as pharmaceuticals and endocrine disruptors, poses challenges for conventional water treatment systems. In an effort to address these contaminants and to support water reuse in drought stricken regions, new technologies must be introduced. The interaction of water with plasma rapidly mineralizes organics by inducing advanced oxidation in addition to other chemical, physical and radiative processes. The primary barrier to the implementation of plasma-based water treatment is process volume scale up. In this work, we investigate a potentially scalable, high throughput plasma water reactor that utilizes a packed bed dielectric barrier-like geometry to maximize the plasma-water interface. Here, the water serves as the dielectric medium. High-speed imaging and emission spectroscopy are used to characterize the reactor discharges. Changes in methylene blue concentration and basic water parameters are mapped as a function of plasma treatment time. Experimental results are compared to electrostatic and plasma chemistry computations, which will provide insight into the reactor's operation so that efficiency can be assessed. Supported by NSF (CBET 1336375).

  8. Numerically Analysed Thermal Condition of Hearth Rollers with the Water-Cooled Shaft

    Directory of Open Access Journals (Sweden)

    A. V. Ivanov

    2016-01-01

    Full Text Available Continuous furnaces with roller hearth have wide application in the steel industry. Typically, furnaces with roller hearth belong to the class of medium-temperature heat treatment furnaces, but can be used to heat the billets for rolling. In this case, the furnaces belong to the class of high temperature heating furnaces, and their efficiency depends significantly on the reliability of the roller hearth furnace. In the high temperature heating furnaces are used three types of watercooled shaft rollers, namely rollers without insulation, rollers with insulating screens placed between the barrel and the shaft, and rollers with bulk insulation. The definition of the operating conditions of rollers with water-cooled shaft greatly facilitates the choice of their design parameters when designing. In this regard, at the design stage of the furnace with roller hearth, it is important to have information about the temperature distribution in the body of the rollers at various operating conditions. The article presents the research results of the temperature field of the hearth rollers of metallurgical heating furnaces. Modeling of stationary heat exchange between the oven atmosphere and a surface of rollers, and between the cooling water and shaft was executed by finite elements method. Temperature fields in the water-cooled shaft rollers of various designs are explored. The water-cooled shaft rollers without isolation, rollers with screen and rollers with bulk insulation, placed between the barrel and the water-cooled shaft were investigated. Determined the change of the thermo-physic parameters of the coolant, the temperature change of water when flowing in a pipe and shaft, as well as the desired pressure to supply water with a specified flow rate. Heat transfer coefficients between the cooling water and the shaft were determined directly during the solution based on the specified boundary conditions. Found that the greatest heat losses occur in the

  9. Optimization of O3 as Pre-Treatment and Chemical Enhanced Backwashing in UF and MF Ceramic Membranes for the Treatment of Secondary Wastewater Effluent and Red Sea Water

    KAUST Repository

    Herrera, Catalina

    2011-12-12

    Ceramic membranes have proven to have many advantages over polymeric membranes. Some of these advantages are: resistance against extreme pH, higher permeate flux, less frequent chemical cleaning, excellent backwash efficiency and longer lifetime. Other main advantage is the use of strong chemical agent such as Ozone (O3), to perform membrane cleaning. Ozone has proven to be a good disinfection agent, deactivating bacteria and viruses. Ozone has high oxidation potential and high reactivity with natural organic matter (NOM). Several studies have shown that combining ozone to MF/UF systems could minimize membrane fouling and getting higher operational fluxes. This work focused on ozone – ceramic membrane filtration for treating wastewater effluent and seawater. Effects of ozone as a pre – treatment or chemical cleaning with ceramic membrane filtration were identified in terms of permeate flux and organic fouling. Ozonation tests were done by adjusting O3 dose with source water, monitoring flux decline and membrane fouling. Backwashing availability and membrane recovery rate were also analyzed. Two types of MF/UF ceramics membranes (AAO and TAMI) were used for this study. When ozone dosage was higher in the source water, membrane filtration improved in performance, resulting in a reduced flux decline. In secondary wastewater effluent, raw source water declined up to 77% of normalized flux, while with O3 as pre – treatment, source water at its higher O3 dose, flux decreased only 33% of normalized flux. For seawater, membrane performance increase from declining to 37% of its final normalized flux to 21%, when O3 as a pre – treatment was used. Membrane recovery rate also improved even with low O3 dose, as an example, with 8 mg/L irreversible fouling decreases from 58% with no ozone addition to 29% for secondary wastewater effluent treatment. For seawater treatment, irreversible fouling decreased from 37% with no ozone addition to 21% at 8 mg/L, proving ozone is a

  10. Cooling Rate Study of Nickel-Rich Material During Thermal Treatment and Quench

    Science.gov (United States)

    Thomas, Fransua; Murguia, Silvia Briseno (Editor)

    2016-01-01

    To investigate quench cracking that results from water quenching after heat treatment of binary and Ni-rich material, cooling rates of specimens were measured during quenching and hardness post-thermal treatment. For specific applications binary Ni-Ti is customarily thermally treated and quenched to attain desired mechanical properties and hardness. However, one problem emerging from this method is thermal cracking, either during the heat treatment process or during the specimen's application. This can result in material and equipment failure as well as financial losses. The objective of the study is to investigate the internal cooling rate of 60-NiTi during quenching and determine possible factors causing thermal cracking. Cubic (1 in.3) samples of both material were heat treated in air at 1000 deg C for 2 hrs and quenched in room temperature water using two methods: (1) dropped in the water and (2) agitated in the water. Hardness of the two fore-mentioned methods was measured post heat treatment. Results indicate that the quenching method had an effect on cooling rate during quenching but hardness was observed to be essentially the same through the thickness of the samples.

  11. Organic Contaminants and Treatment Chemicals in Steam-Water Cycles: Thermal stability, decomposition products and flow-accelerated corrosion

    NARCIS (Netherlands)

    Moed, D.H.

    2015-01-01

    Boiler feedwater and steam have to be of high purity, because of the susceptibility of the steam-water cycle to corrosion. Organic contaminants break down in boilers by hydrothermolysis, leading to the formation of organic acid anions, which are suspected to cause corrosion of steam-water cycle

  12. Organic Contaminants and Treatment Chemicals in Steam-Water Cycles: Thermal stability, decomposition products and flow-accelerated corrosion

    NARCIS (Netherlands)

    Moed, D.H.

    2015-01-01

    Boiler feedwater and steam have to be of high purity, because of the susceptibility of the steam-water cycle to corrosion. Organic contaminants break down in boilers by hydrothermolysis, leading to the formation of organic acid anions, which are suspected to cause corrosion of steam-water cycle comp

  13. Water Treatment Technology - Filtration.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on filtration provides instructional materials for six competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: purposes of sedimentation basins and flocculation…

  14. Water Treatment Technology - Springs.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on springs provides instructional materials for two competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on spring basin construction and spring protection. For each competency, student…

  15. Water Treatment Technology - Wells.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on wells provides instructional materials for five competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: dug, driven, and chilled wells, aquifer types, deep well…

  16. Water Treatment Technology - Flouridation.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on flouridation provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: purpose and process of flouridation, correct…

  17. Water Treatment Technology - Pumps.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on pumps provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pumps in plant and distribution systems, pump…

  18. Water Treatment Technology - Hydraulics.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on hydraulics provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: head loss in pipes in series, function loss in…

  19. Water Treatment Technology - Chlorination.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on chlorination provides instructional materials for nine competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: purpose and process of chlorination, chlorine…

  20. WRI 50: Strategies for Cooling Electric Generating Facilities Utilizing Mine Water

    Energy Technology Data Exchange (ETDEWEB)

    Joseph J. Donovan; Brenden Duffy; Bruce R. Leavitt; James Stiles; Tamara Vandivort; Paul Ziemkiewicz

    2004-11-01

    Power generation and water consumption are inextricably linked. Because of this relationship DOE/NETL has funded a competitive research and development initiative to address this relationship. This report is part of that initiative and is in response to DOE/NETL solicitation DE-PS26-03NT41719-0. Thermal electric power generation requires large volumes of water to cool spent steam at the end of the turbine cycle. The required volumes are such that new plant siting is increasingly dependent on the availability of cooling circuit water. Even in the eastern U.S., large rivers such as the Monongahela may no longer be able to support additional, large power stations due to subscription of flow to existing plants, industrial, municipal and navigational requirements. Earlier studies conducted by West Virginia University (WV 132, WV 173 phase I, WV 173 Phase II, WV 173 Phase III, and WV 173 Phase IV in review) have identified that a large potential water resource resides in flooded, abandoned coal mines in the Pittsburgh Coal Basin, and likely elsewhere in the region and nation. This study evaluates the technical and economic potential of the Pittsburgh Coal Basin water source to supply new power plants with cooling water. Two approaches for supplying new power plants were evaluated. Type A employs mine water in conventional, evaporative cooling towers. Type B utilizes earth-coupled cooling with flooded underground mines as the principal heat sink for the power plant reject heat load. Existing mine discharges in the Pittsburgh Coal Basin were evaluated for flow and water quality. Based on this analysis, eight sites were identified where mine water could supply cooling water to a power plant. Three of these sites were employed for pre-engineering design and cost analysis of a Type A water supply system, including mine water collection, treatment, and delivery. This method was also applied to a ''base case'' river-source power plant, for comparison. Mine-water

  1. Scaling up the chemical treatment of spent oil-in-water emulsions from a non-ferrous metal-processing plant

    Directory of Open Access Journals (Sweden)

    Lazarević Vesna B.

    2013-01-01

    Full Text Available The treatment of spent oil-in-water emulsion (SOWE from a non-ferrous metal-processing plant by using aluminum sulfate and hydrated lime was studied to determine the purification efficiency, to optimize the operating conditions and to scale up the treatment process. The purification efficiency was estimated by comparing the compositions of the SOWE and the processed wastewater. The treatment efficiency does not depend on the type of mineral oil and filter aid. The optimum doses of aluminum sulfate and hydrated lime must be experimentally determined for each batch of SOWEs, but the results obtained at laboratory level are applicable at pilot level. The processed wastewater and the filter cake from the process can be safely disposed into public sewage systems and at municipal waste landfills, respectively. The purification efficiency was higher than 98% with respect to total suspended solids, chemical oxygen demand and oil and grease, and was comparable to the known treatment processes based on coagulation/flocculation followed by sedimentation.

  2. 电吸附技术在循环冷却水系统排污水处理中的应用%Application of electrosorb technology in treatment of sewage discharged from circulating cooling water system

    Institute of Scientific and Technical Information of China (English)

    李永辉

    2012-01-01

    采用电吸附除盐技术,对循环冷却水系统排污水进行除盐效果中试研究.试验表明电吸附技术对电导率的平均去除率为76.3%,产水率为76.1%,对氯离子、钙离子都有良好的去除效果,产水水质能够达到循环冷却水系统补充水的要求.%Electrosorb technology was used to treat sewage discharged from circulating cooling water system, and its desalination performance was studied through a pilot scale test. The results of the test showed that, using electrosorb technology to treat the said kind of sewage, the average removal rate of conductivity reached 76.3%, the water production rate was 76.1%, the removal rates of chlorine ion and calcium ion were both satisfactory, and the produced water quality could meet the specification for make—up water of circulating cooling water system.

  3. Performance characteristics in hydrodynamic water cooled thrust bearings

    Directory of Open Access Journals (Sweden)

    Farooq Ahmad Najar

    2016-09-01

    Full Text Available This paper deals with the study of the influence on performance characteristics of a thrust bearing with the introduction of cooling circuit and flow velocity of coolant within the designed thrust bearings is described. New method of cooling circuit configuration is taken into consideration and water has been chosen as a coolant here in the present work. Flow velocity of coolant, ranging from 0.5m/s to 2.0m/s is proposed. The Finite difference based numerical model has been developed in order to notice the effect on the heat transfer on a large hydrodynamic lubrication thrust bearing in-terms of its performance characteristics. In the present work, the solution of Reynolds equation, an energy equation with viscosity variation and Fourier heat conduction equations, applied with appropriate boundary conditions. From the present investigation, it is observed significant amount of heat content is removed from the bearing with the increase of flow velocity of coolant in an embedded cooling duct within the pad. An important parameter among performance characteristics has prevailed a significant increase in hydrodynamic pressure generation which in turn subsequently increases the load carrying capacity which has been never ever documented in the background literature.

  4. Membrane fouling and chemical cleaning of water treatment ultra filters in chemical plants%化工厂用水超滤处理中膜污染及化学清洗方法

    Institute of Scientific and Technical Information of China (English)

    田晶; 王丁; 荣玥

    2012-01-01

    以某化工厂除盐水处理工程为例,阐述了超滤装置的工艺流程和运行方式,分析了超滤的工作原理及处理过程中膜污染的形成原因,提出了控制膜污染的化学清洗方法和清洗控制参数,为此类水处理工艺的日常运行管理和维护提供技术参考。%According to the desalination water treatment engineering in a chemical plant, the process and operation mode of ultra filtration device was described, principle of ultra filtration and causes of membrane fouling were analyzed. The chemical cleaning of membrane fouling and cleaning parameters control methods listed in the article is technical reference for the daily operation, management and maintenance of this water treatment process.

  5. Performance of a novel microwave-based treatment technology for atrazine removal and destruction: Sorbent reusability and chemical stability, and effect of water matrices

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Erdan; Hu, Yuanan [State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Cheng, Hefa, E-mail: hefac@umich.edu [State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); MOE Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing 100871 (China)

    2015-12-15

    Highlights: • Cu{sup 2+} and Fe{sup 3+} in zeolite pores enhance atrazine sorption and MW-induced degradation. • Exchanged zeolites perform well over multiple sorption–regeneration cycles. • Fe{sup 3+} species in the zeolite micropores have much greater stability than those of Cu{sup 2+}. • DOC in natural waters can compromise the sorption capacity of exchanged zeolites. • Iron-exchanged dealuminated Y zeolites hold great promise for practical applications. - Abstract: Transition metal-exchanged dealuminated Y zeolites were used to adsorb atrazine from aqueous solutions, followed by regeneration of the sorbents and destruction of the sorbed atrazine with microwave irradiation. Exchange of copper and iron into the zeolite's micropores significantly enhanced its sorption capacity and selectivity toward atrazine, and increased the microwave-induced degradation rate of the sorbed atrazine by 3–4-folds. Both the copper- and iron-exchanged zeolites could be regenerated and reused multiple times, while the catalytic activity of the latter was more robust due to the much greater chemical stability of Fe{sup 3+} species in the micropores. The presence of humic acid, and common cations and anions had little impact on the sorption of atrazine on the transition metal-exchanged zeolites. In the treatment of atrazine spiked in natural surface water and groundwater samples, sorptive removal of atrazine was found to be impacted by the level of dissolved organic carbon, probably through competition for the micropore spaces and pore blocking, while the water matrices exhibited no strong effect on the microwave-induced degradation of sorbed atrazine. Overall, iron-exchanged dealuminated Y zeolites show great potential for removal and destruction of atrazine from contaminated surface water and groundwater in practical implementation of the novel treatment technology.

  6. Preliminary Investigation on the Useful Chemicals obtained from High-Temperature and High-Pressure Water Treatment of Hinoki (Chamaecyparis Obutus Bark

    Directory of Open Access Journals (Sweden)

    Hiroyuki Daimon

    2010-12-01

    Full Text Available The possibility of utilizing residual forest biomass to produce valuable chemicals was investigated. An outer layer of a bark of Hinoki (Chamaecyparis obutusa tree, a Japanese cypress, was used as a sample material. Experiments were carried out in a semibatch reactor apparatus that allows the study of the effect of reaction temperatures in a single run. Analysis of the products by GC-MS reveals formation of useful compounds such as furfural, some aromatic compounds (1,3-di-tert-butyl benzene and 2,4-di-tert-butyl phenol, and fatty acids (myristic acid, palmitic acid and stearic acid. Keywords: fatty acids, furfural, high temperature water treatment, hinoki, residual biomass

  7. Water in Biological and Chemical Processes

    Science.gov (United States)

    Bagchi, Biman

    2013-11-01

    Part I. Bulk Water: 1. Uniqueness of water; 2. Anomalies of water; 3. Dynamics of water: molecular motions and hydrogen bond breaking kinetics; 4. Inherent structures of liquid water; 5. pH of water; Part II. Water in Biology: Dynamical View and Function: 6. Biological water; 7. Explicit role of water in biological functions; 8. Hydration of proteins; 9. Can we understand protein hydration layer: lessons from computer simulations; 10. Water in and around DNA and RNA; 11. Role of water in protein-DNA interaction; 12. Water surrounding lipid bilayers; 13. Water in Darwin's world; Part III. Water in Complex Chemical Systems: 14. Hydrophilic effects; 15. Hydrophobic effects; 16. Aqueous binary mixtures: amphiphilic effect; 17. Water in and around micelles, reverse micelles and microemulsions; 18. Water in carbon nanotubes; Part IV. Bulk Water: Advanced Topics: 19. Entropy of water; 20. Freezing of water into ice; 21. Supercritical water; 22. Microscopic approaches to understand water anomalies.

  8. ALTERNATIVE DISINFECTION FOR DRINKING WATER TREATMENT

    Science.gov (United States)

    During a one-yr study at Jefferson Parish, La., the chemical, microbiological, and mutagenic effects os using the major drinkgin water disinfectants (chlorine, chlorine dioxide, chloramine, ozone) were evaluated. Tests were performed on samples collected from various treatment s...

  9. Pilot-scale cooling tower to evaluate corrosion, scaling, and biofouling control strategies for cooling system makeup water.

    Science.gov (United States)

    Chien, S H; Hsieh, M K; Li, H; Monnell, J; Dzombak, D; Vidic, R

    2012-02-01

    Pilot-scale cooling towers can be used to evaluate corrosion, scaling, and biofouling control strategies when using particular cooling system makeup water and particular operating conditions. To study the potential for using a number of different impaired waters as makeup water, a pilot-scale system capable of generating 27,000 kJ∕h heat load and maintaining recirculating water flow with a Reynolds number of 1.92 × 10(4) was designed to study these critical processes under conditions that are similar to full-scale systems. The pilot-scale cooling tower was equipped with an automatic makeup water control system, automatic blowdown control system, semi-automatic biocide feeding system, and corrosion, scaling, and biofouling monitoring systems. Observed operational data revealed that the major operating parameters, including temperature change (6.6 °C), cycles of concentration (N = 4.6), water flow velocity (0.66 m∕s), and air mass velocity (3660 kg∕h m(2)), were controlled quite well for an extended period of time (up to 2 months). Overall, the performance of the pilot-scale cooling towers using treated municipal wastewater was shown to be suitable to study critical processes (corrosion, scaling, biofouling) and evaluate cooling water management strategies for makeup waters of complex quality.

  10. Research on variation of water quality chemical stability during the water treatment process%水质化学稳定性沿工艺流程变化研究

    Institute of Scientific and Technical Information of China (English)

    张庆; 梅红

    2012-01-01

    通过研究水质化学稳定性随水处理工艺流程的变化,探讨影响水质化学稳定性的因素.结果表明:水处理中碱度消耗工艺(混凝、生物活性炭和臭氧氧化工艺)均使水质化学稳定性下降.生物活性炭滤池运行初期生物膜未形成或尚不成熟时,对水质化学稳定性基本无影响,相反,初期活性炭表面金属溶出还可能改善水质化学稳定性.氯胺消毒基本不影响水质化学稳定性,投加NaClO可提高水质化学稳定性.混凝剂投加后增加水中无机阴离子(SO42-和Cl-),增加水体对管道的腐蚀倾向.%Through studying the variation of water quality chemical stability during the water treatment process, the factors influencing the water quality chemical stability were discussed. The results showed that: alkalinity consumption processes (coagulation, biological activated carbon and ozone oxidation) deteriorated the water quality chemical stability. There was almost no influence on water quality chemical stability when biofilm was not formed or not yet mature in the early operation period of biological activated carbon filter. On the contrary, the metal precipitation on the surface of the activated carbon happened in the initial stage might improve the water quality chemical stability. The water quality chemical stability was almost not influenced by chloramines disinfection, but was improved by adding NaClO. As coagulant dosing increased the concentration of the dissolved inorganic anions (SO24- and Cl-), the corrosion tendency of the iron pipe was also aggravated.

  11. Household Water Treatments in Developing Countries

    Science.gov (United States)

    Smieja, Joanne A.

    2011-01-01

    Household water treatments (HWT) can help provide clean water to millions of people worldwide who do not have access to safe water. This article describes four common HWT used in developing countries and the pertinent chemistry involved. The intent of this article is to inform both high school and college chemical educators and chemistry students…

  12. Household Water Treatments in Developing Countries

    Science.gov (United States)

    Smieja, Joanne A.

    2011-01-01

    Household water treatments (HWT) can help provide clean water to millions of people worldwide who do not have access to safe water. This article describes four common HWT used in developing countries and the pertinent chemistry involved. The intent of this article is to inform both high school and college chemical educators and chemistry students…

  13. A Study on the Waste Water Treatment Technology for Steel Industry: Recycle And Reuse.

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Sinha

    2016-08-01

    Full Text Available The steel industry is one of the most important and vital Industry of the present and the future. It is the asset of a nation. Steel plants use a tremendous amount of water for waste transfer, cooling and dust control. The steel plants have sintering mills, coke plants, blast furnaces, chemical byproducts and chemical processes, water cooled rolls, pumps, extrusion experiment, transfer lines for sludges and slurries. All these plants use a tremendous amount of water to cool the products and flush the impurities away from the finished stock. Wastewater is generated in huge quantity in steel industries. It contains many dissolved, undisclosed substances and chemicals in the wastewater. The steel industries produce wastewater and sludge during different industrial processes. The development of innovative technologies for treatment of wastewaters from steel industries is a matter of alarming concern for us. Although many research papers have been reported on wastewater pollution control studies, but a very few research work is carried out for treatment of wastewater of steel industries, especially in reference to development of design of industrial effluent Treatment Plants (ETP system. Another beneficial aspect of this research work will be recycling, reuse of water and sludge from steel industry The whole technologies for treating industrial wastewater can be divided into four categories: - Chemical, Physical, Biological and mathematical approaches. Physical treatment methods include sedimentation, Floatation , filtering , stripping, ion – exchange, adsorption and other processes that accomplish removal of dissolved and undisclosed substances without necessarily changing their chemical structure. The mathematical approaches are very useful and more realistic for developing a well operating cost–effective treatment system for industrial wastewater treatment.

  14. MODIFIKASI PATI GARUT (Marantha arundinacea) DENGAN PERLAKUAN SIKLUS PEMANASAN SUHU TINGGI-PENDINGINAN ( AUTOCLAVING-COOLING CYCLING) UNTUK MENGHASILKAN PATI RESISTEN TIPE III [Arrowroot (Marantha arundinacea) Starch Modification Through Autoclaving-Cooling Cycling Treatment to Produce Resistant Starch Type III

    OpenAIRE

    Sugiyono*; Ratih Pratiwi2); Didah Nur Faridah

    2009-01-01

    The objectives of this research were to modify arrowroot starch to produce resistant starch type III by autoclaving-cooling cycling and to characterize the modified arrowroot starches according to their chemical properties. The research consisted of three steps : arrowroot extraction, starch modification, and chemical characterization. The extraction of arrowroot produced 10.78% starch. Starch modification by autoclaving-cooling cycle(s) was run in 6 different treatments with the aim of obser...

  15. Applicability of a desiccant dew-point cooling system independent of external water sources

    DEFF Research Database (Denmark)

    Bellemo, Lorenzo; Elmegaard, Brian; Kærn, Martin Ryhl

    2015-01-01

    The applicability of a technical solution for making desiccant cooling systems independent of external water sources is investigated. Water is produced by condensing the desorbed water vapour in a closed regeneration circuit. Desorbed water recovery is applied to a desiccant dew-point cooling...

  16. Experimental study of the decrease in the temperature of an air/water-cooled turbine blade

    Science.gov (United States)

    Ryzhov, A. A.; Sereda, A. V.; Shaiakberov, V. F.; Iskakov, K. M.; Shatalov, Iu. S.

    Results of the full-scale testing of an air/water-cooled deflector-type turbine blade are reported. Data on the decrease in the temperature of the cooling air and of the blade are presented and compared with the calculated values. An analysis of the results indicates that the use of air/water cooling makes it possible to significantly reduce the temperature of the cooling air and of the blade with practically no increase in the engine weight and dimensions.

  17. Optimum hot water temperature for absorption solar cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lecuona, A.; Ventas, R.; Venegas, M.; Salgado, R. [Dpto. Ingenieria Termica y de Fluidos, Universidad Carlos III de Madrid, Avda. Universidad 30, 28911 Leganes, Madrid (Spain); Zacarias, A. [ESIME UPA, IPN, Av. de las Granjas 682, Col. Santa Catarina, 02550, D.F. Mexico (Mexico)

    2009-10-15

    The hot water temperature that maximizes the overall instantaneous efficiency of a solar cooling facility is determined. A modified characteristic equation model is used and applied to single-effect lithium bromide-water absorption chillers. This model is based on the characteristic temperature difference and serves to empirically calculate the performance of real chillers. This paper provides an explicit equation for the optimum temperature of vapor generation, in terms of only the external temperatures of the chiller. The additional data required are the four performance parameters of the chiller and essentially a modified stagnation temperature from the detailed model of the thermal collector operation. This paper presents and discusses the results for small capacity machines for air conditioning of homes and small buildings. The discussion highlights the influence of the relevant parameters. (author)

  18. Dechlorination Technology Manual. Final report. [Utility cooling water discharge systems

    Energy Technology Data Exchange (ETDEWEB)

    Aschoff, A.F.; Chiesa, R.J.; Jacobs, M.H.; Lee, Y.H.; Mehta, S.C.; Meko, A.C.; Musil, R.R.; Sopocy, D.M.; Wilson, J.A.

    1984-11-01

    On November 19, 1982, the United States Environmental Protection Agency (EPA) promulgated regulations severely restricting chlorination practices as they relate to utility cooling water discharge systems. EPRI authorized the preparation of a manual on dechlorination technology to assist utilities in evaluating the various alternatives available to them to meet these new requirements. The Dechlorination Technology Manual emphasizes the engineering aspects involved in the selection and design of dechlorination systems. However, background information is included concerning chemistry, regulatory requirements, environmental considerations and aquatic impacts. There is also a brief discussion of the various alternatives to dechlorination. Case studies are given to acquaint the user with the use of the manual for the design of chlorination facilities given various site-related characteristics, such as salt versus fresh waters. Numerous graphs and tables are presented to facilitate the selection and design process. 207 references, 66 figures, 60 tables.

  19. NGC 6388: Chemical Composition of Its Eight Cool Giants

    Science.gov (United States)

    Wallerstein, G.; Kovtyukh, V. V.; Andrievsky, S. M.

    2007-04-01

    Eight cool giants in the unusual globular cluster NGC 6388 have been investigated in order to derive their elemental abundances. Effective temperatures from 3500 to 3850 K were derived using the method of line-depth ratios. Surface gravities were derived in two ways. Spectroscopic gravities, derived by the requirement that the abundance of iron be the same from Fe I and Fe II lines, were rather low, ranging from -0.3 to 0.0. Photometric gravities, derived from the assumed stellar mass of 0.7 Modot and the luminosity and Teff of the stars, fell between +0.25 and +0.70. Mean [Fe/H] values were -0.8 for spectroscopic gravities and -0.6 for photometric gravities. A test using spectra of the same resolution of the two coolest red giants in the globular cluster M4 obtained at the Apache Point Observatory were analyzed for comparison with the definitive analysis of Ivans et al. (1999). The very cool metal-poor red giant HD 232078 was also analyzed for comparison with the analysis of Gonzalez & Wallerstein (1998). Both comparisons showed that our methods yield the same abundance scale as previous works. We have compared the composition of stars in NGC 6388 with those of K giants with similar [Fe/H] in 47 Tuc and the Galactic bulge. The observed value of [O/Fe] is near zero, which is less than in 47 Tuc and bulge stars of similar metallicity. The α-elements behave similarly to oxygen and show only small excesses at about the same level as do the α-elements in the globular clusters associated with the Sgr system. It is unclear whether these differences are responsible for the unusual color-magnitude diagram of NGC 6388.

  20. Heat Transfer Modeling of an Annular On-Line Spray Water Cooling Process for Electric-Resistance-Welded Steel Pipe.

    Science.gov (United States)

    Chen, Zejun; Han, Huiquan; Ren, Wei; Huang, Guangjie

    2015-01-01

    On-line spray water cooling (OSWC) of electric-resistance-welded (ERW) steel pipes can replace the conventional off-line heat treatment process and become an important and critical procedure. The OSWC process improves production efficiency, decreases costs, and enhances the mechanical properties of ERW steel pipe, especially the impact properties of the weld joint. In this paper, an annular OSWC process is investigated based on an experimental simulation platform that can obtain precise real-time measurements of the temperature of the pipe, the water pressure and flux, etc. The effects of the modes of annular spray water cooling and related cooling parameters on the mechanical properties of the pipe are investigated. The temperature evolutions of the inner and outer walls of the pipe are measured during the spray water cooling process, and the uniformity of mechanical properties along the circumferential and longitudinal directions is investigated. A heat transfer coefficient model of spray water cooling is developed based on measured temperature data in conjunction with simulation using the finite element method. Industrial tests prove the validity of the heat transfer model of a steel pipe undergoing spray water cooling. The research results can provide a basis for the industrial application of the OSWC process in the production of ERW steel pipes.

  1. Heat Transfer Modeling of an Annular On-Line Spray Water Cooling Process for Electric-Resistance-Welded Steel Pipe

    Science.gov (United States)

    Chen, Zejun; Han, Huiquan; Ren, Wei; Huang, Guangjie

    2015-01-01

    On-line spray water cooling (OSWC) of electric-resistance-welded (ERW) steel pipes can replace the conventional off-line heat treatment process and become an important and critical procedure. The OSWC process improves production efficiency, decreases costs, and enhances the mechanical properties of ERW steel pipe, especially the impact properties of the weld joint. In this paper, an annular OSWC process is investigated based on an experimental simulation platform that can obtain precise real-time measurements of the temperature of the pipe, the water pressure and flux, etc. The effects of the modes of annular spray water cooling and related cooling parameters on the mechanical properties of the pipe are investigated. The temperature evolutions of the inner and outer walls of the pipe are measured during the spray water cooling process, and the uniformity of mechanical properties along the circumferential and longitudinal directions is investigated. A heat transfer coefficient model of spray water cooling is developed based on measured temperature data in conjunction with simulation using the finite element method. Industrial tests prove the validity of the heat transfer model of a steel pipe undergoing spray water cooling. The research results can provide a basis for the industrial application of the OSWC process in the production of ERW steel pipes. PMID:26201073

  2. Development of Horizontal Water-cooled Convertor and Its Application in Modern Coal Chemical Industry%卧式水冷反应器技术开发及其在现代煤化工领域应用分析

    Institute of Scientific and Technical Information of China (English)

    楼韧; 冯再南; 粟杨; 周小波; 王俊峰; 周传华

    2011-01-01

    The technical features of the new horizontal water-cooled convertors were expatiated on.Introduced alsowere the application prospect of this convertor in the large methanol synthesis, SNG, coal-to-ethylene glycol, single-process DME, single-process MTG via syngas, IGCC with chemicals co-production etc.%简要介绍了卧式水冷反应器技术开发过程,分析了新型卧式水冷反应器技术特点,详细介绍了该反应器在大型甲醇、人工天然气、煤制乙二醇、一步法合成气经甲醇制汽油和化工-IGCC联产等现代煤化工上的应用前景.

  3. Development of a water-mist cooling system: A 12,500 Kcal/h air-cooled chiller

    Directory of Open Access Journals (Sweden)

    Chung-Neng Huang

    2015-11-01

    Full Text Available Global warming and energy exhaustion problems are becoming a severe problems, of which energy conservation and carbon reduction are the most critical. Between 40% and 48% of the total electricity used in a building is consumed by air conditioning systems. The development of a supersonic water-misting cooling system with a fuzzy control system is proposed to optimize existing condenser noise, space, and energy consumption, as well as to address problems with cooling capacity resulting from improper control between compressors and condensers. An experimental platform was established for conducting tests, observing cooling efficiencies, and calculating power saving statuses. Comparing the observed cooling efficiency, a temperature difference of 5.4 °C was determined before and after the application; this is significant regarding efficiency. The method produces no pollution or water accumulation. When compared with fixed frequency air-cooled water chillers, an exceptional energy saving of 25% was observed. The newly developed supersonic mist-cooled chiller is an excellent solution to increasing water and electricity fees.

  4. Secondary Cooling Water Quality Management for Multi Purpose Reactor 30 MW GA Siwabessy Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Sunaryo, Geni Rina, E-mail: genirina@batan.go.i [Center for Reactor Technology and Nuclear Safety (PTRKN-BATAN), Bldg. 80, Puspiptek Area, Serpong, Tangerang 15310 (Indonesia)

    2011-07-01

    Indonesia Multi Purpose Research Reactor (MPR) G.A. Siwabessy 30 MW will be 25 years old in 2011. Series of Non Destructive Test (NDT) were done to understand the current condition such as Eddy Current test for Heat Exchangers, water immersed camera for understanding the tank liner condition, ultrasonic for secondary piping etc. Some deteorization was observed because of ageing and some changing was done. One of them is changing some part of secondary pipe lines because of leaking, with the local ones. For having another 25 years operation life, a proper water quality for secondary cooling water is needed towards corrosion prevention. The main objectives of this experiment is to understand the current water quality of secondary cooling water of RSG-GAS from the aspect of corrosion induced by chemicals and bacteria, and establish procedure for managing the secondary cooling water quality. Methodologies applied are surveillance corrosion by immersing coupon into water observed and followed by visual analyses, corrosion rate determination by electrochemical method with various chemical conditions and total bacteria determination by using test kit. The results show visually that the crevice, galvanic and homogeny corrosion with the current water quality easily be observed for carbon steel represented secondary pipelines at the condition of none oxy bio agent addition. This corrosion is being suppressed by adding the oxy bio agent. The orientation of coupon, vertically and horizontally, gives slightly different effect. The closely corrosion rate was obtained by separately experiment, electrochemical, at the concentration of inhibitor 100ppm is 0.13 {+-} 0.02, which is lower than in the raw water of 0.20 {+-} 0.01 mpy. The total bacteria detected is around 10{sup 7} cfu/ml at none reactor operation and without any anti bacteria added. The oxi bio agent chemical addition suppresses the numbers becomes 10{sup 3} cfu/ml. The SRB bacteria is detected as >10{sup 6} cfu/ml at

  5. Which chemicals drive biological effects in wastewater and recycled water?

    Science.gov (United States)

    Tang, Janet Y M; Busetti, Francesco; Charrois, Jeffrey W A; Escher, Beate I

    2014-09-01

    Removal of organic micropollutants from wastewater during secondary treatment followed by reverse osmosis and UV disinfection was evaluated by a combination of four in-vitro cell-based bioassays and chemical analysis of 299 organic compounds. Concentrations detected in recycled water were below the Australian Guidelines for Water Recycling. Thus the detected chemicals were considered not to pose any health risk. The detected pesticides in the wastewater treatment plant effluent and partially advanced treated water explained all observed effects on photosynthesis inhibition. In contrast, mixture toxicity experiments with designed mixtures containing all detected chemicals at their measured concentrations demonstrated that the known chemicals explained less than 3% of the observed cytotoxicity and less than 1% of the oxidative stress response. Pesticides followed by pharmaceuticals and personal care products dominated the observed mixture effects. The detected chemicals were not related to the observed genotoxicity. The large proportion of unknown toxicity calls for effect monitoring complementary to chemical monitoring.

  6. A new approach for water treatment

    CERN Document Server

    Principe, R

    1999-01-01

    A quantity of up to 4000 m3/h of water is used at CERN for cooling purposes: experiments, magnets and radio frequency cavities are refrigerated by closed circuits filled with deionized water; other utilities, such as air-conditioning, use chilled/hot water, also in closed circuits. All these methods all employ a cold source, the primary supply of water, coming from the cooling towers. About 500 kCHF are spent every year on water treatment in order to keep the water within these networks in operational conditions. In the line of further rationalization of resources, the next generation of contracts with the water treatment industry will aim for improved performance and better monitoring of quality related parameters in this context. The author will provide a concise report based upon an examination of the state of the installations and of the philosophy followed up until now for water treatment. Furthermore, he/she will propose a new approach from both a technical and contractual point of view, in preparation ...

  7. Study of using microfiltration and reverse osmosis membrane technologies for reclaiming cooling water in the power industry.

    Science.gov (United States)

    Li, J; Xu, Z Y; An, H G; Liu, L Q

    2007-07-01

    A study of using dual membrane technologies, microfiltration (MF) and reverse osmosis (RO), for reclaiming blowdown of the cooling tower was conducted at ZJK power plant, Hebei province, China. The study shows that the combined MF-RO system can effectively reduce water consumption in the power industry. The results indicate that MF process is capable of producing a filtrate suitable for RO treatment and achieving a silt density index (SDI) less than 2, turbidity of 0.2 NTU. The water quality of RO effluent is very good with an average conductivity of about 40 micros/cm and rejection of 98%. The product water is suitable for injection into the cooling tower to counteract with cooling water intrusion. After adopting this system, water-saving effectiveness as expressed in terms of cycles of concentration could be increased from 2.5-2.8 times to 5 times.

  8. Enhancement of heat transfer in Czochralski growth of silicon crystals with a chemical cooling technique

    Science.gov (United States)

    Ding, Junling; Liu, Lijun; Zhao, Wenhan

    2017-06-01

    The cost of producing single-crystalline silicon with the Czochralski method can be reduced by promoting the crystal size and/or crystal pulling rate. However, more latent heat of solidification needs to be released from the melt-crystal (m-c) interface during the crystal growth process. In this study, the C-CO2 chemical endothermic reaction is proposed as a novel and efficient cooling technique to solve this problem. Compared with the conventional gas cooling method, C-CO2 endothermic reaction method can significantly enhance the heat transfer in the crystal at the m-c interface. It was found that the heat transfer is more enhanced with a chemical reaction of smaller activation energy, and the m-c interface becomes flatter. The influence of the carbon concentration in the chemical reactive gas flow on the heat removal in the crystal at the m-c interface is also investigated. The cooling effect is significantly increased with the increase in the carbon concentration when it is small. However, when the carbon concentration in the reactive gas is high, the cooling effect just increases slightly. The research demonstrates that the proposed chemical endothermic reaction is a promising cooling technique to be applied in CZ-Si crystal growth with large size/high pulling rate.

  9. DEMONSTRATION BULLETIN: PEROX-PURE CHEMICAL OXIDATION TREATMENT

    Science.gov (United States)

    Technology Description: The perox-pure™ chemical oxidation treatment technology was developed by Peroxidation Systems, Inc. (PSI), to destroy dissolved organic contaminants in water. The technology uses ultraviolet (UV) radiation and hydrogen peroxide to oxidize organic co...

  10. Basic Water Treatment Operation.

    Science.gov (United States)

    Ontario Ministry of the Environment, Toronto.

    This manual was developed for use at workshops designed to introduce the fundamentals of water treatment plant operations. The course consists of lecture-discussions and hands-on activities. Each of the fourteen lessons in this document has clearly stated behavioral objectives to tell the trainee what he should know or do after completing that…

  11. Physico-chemical water characteristics and aquatic ...

    African Journals Online (AJOL)

    Physico-chemical water characteristics and aquatic macroinvertebrates of Lake ... Saline lakes are known to be amongst the most productive ecosystems in the world. ... birds, knowledge of its water characteristics and aquatic biota is scarce.

  12. A STUDY ON LEGIONELLA PNEUMOPHILA, WATER CHEMISTRY, AND ATMOSPHERIC CONDITIONS IN COOLING TOWERS AT THE SAVANNAH RIVER SITE

    Energy Technology Data Exchange (ETDEWEB)

    Smith, C.; Brigmon, R.

    2009-10-20

    Legionnaires disease is a pneumonia caused by the inhalation of the bacterium Legionella pneumophila. The majority of illnesses have been associated with cooling towers since these devices can harbor and disseminate the bacterium in the aerosolized mist generated by these systems. Historically, Savannah River Site (SRS) cooling towers have had occurrences of elevated levels of Legionella in all seasons of the year and in patterns that are difficult to predict. Since elevated Legionella in cooling tower water are a potential health concern a question has been raised as to the best control methodology. In this work we analyze available chemical, biological, and atmospheric data to determine the best method or key parameter for control. The SRS 4Q Industrial Hygiene Manual, 4Q-1203, 1 - G Cooling Tower Operation and the SRNL Legionella Sampling Program, states that 'Participation in the SRNL Legionella Sampling Program is MANDATORY for all operating cooling towers'. The resulting reports include L. pneumophila concentration information in cells/L. L. pneumophila concentrations >10{sup 7} cells/L are considered elevated and unsafe so action must be taken to reduce these densities. These remedial actions typically include increase biocide addition or 'shocking'. Sometimes additional actions are required if the problem persists including increase tower maintenance (e.g. cleaning). Evaluation of 14 SRS cooling towers, seven water quality parameters, and five Legionella serogroups over a three-plus year time frame demonstrated that cooling tower water Legionella densities varied widely though out this time period. In fact there was no one common consistent significant variable across all towers. The significant factors that did show up most frequently were related to suspended particulates, conductivity, pH, and dissolved oxygen, not chlorine or bromine as might be expected. Analyses of atmospheric data showed that there were more frequent significant

  13. The practice of chemical treatment of the water/steam circuits in plants with forced flow once-through boilers. Praxis der chemischen Konditionierung von Wasser-Dampfkreislaeufen in Anlagen mit Zwangdurchlaufkesseln

    Energy Technology Data Exchange (ETDEWEB)

    Bursik, A. (Grosskraftwerk Mannheim AG (Germany)); Kittel, H. (VGB-Geschaeftsstelle, Essen (Germany))

    1992-02-01

    In 1990, a statistical survey was undertaken into the status of chemical treatment of water/steam circuits in plants with once-through forced-flow boilers. The results were reported at the VGB Conference on 'Chemistry in the Power Station 1990'. This paper imparts to the operators of plants with once-through forced-flow boilers additional information about the practice of chemical treatment. It contains guidelines concerning the chemicals used and also instructions about dosing points for individual materials and the type of dosing to be used in continuous operation. (orig.).

  14. Feasibility Study of Venus Surfuce Cooling Using Chemical Reactions with the Atmosphere

    Science.gov (United States)

    Evans, Christopher

    2013-01-01

    A literature search and theoretical analysis were conducted to investigate the feasibility of cooling a craft on Venus through chemical reformation of materials from the atmosphere. The core concept was to take carbon dioxide (CO2) from the Venus atmosphere and chemically reform it into simpler compounds such as carbon, oxygen, and carbon monoxide. This process is endothermic, taking energy from the surroundings to produce a cooling effect. A literature search was performed to document possible routes for achieving the desired reactions. Analyses indicated that on Venus, this concept could theoretically be used to produce cooling, but would not perform as well as a conventional heat pump. For environments other than Venus, the low theoretical performance limits general applicability of this concept, however this approach to cooling may be useful in niche applications. Analysis indicated that environments with particular atmospheric compositions and temperatures could allow a similar cooling system to operate with very good performance. This approach to cooling may also be useful where the products of reaction are also desirable, or for missions where design simplicity is valued. Conceptual designs for Venus cooling systems were developed using a modified concept, in which an expendable reactant supply would be used to promote more energetically favorable reactions with the ambient CO2, providing cooling for a more limited duration. This approach does not have the same performance issues, but the use of expendable supplies increases the mass requirements and limits the operating lifetime. This paper summarizes the findings of the literature search and corresponding analyses of the various cooling options

  15. Feasibility Study of Venus Surface Cooling Using Chemical Reactions with the Atmosphere

    Science.gov (United States)

    Evans, Christopher

    2013-01-01

    A literature search and theoretical analysis were conducted to investigate the feasibility of cooling a craft on Venus through chemical reformation of materials from the atmosphere. The core concept was to take carbon dioxide (CO2) from the Venus atmosphere and chemically reform it into simpler compounds such as carbon, oxygen, and carbon monoxide. This process is endothermic, taking energy from the surroundings to produce a cooling effect. A literature search was performed to document possible routes for achieving the desired reactions. Analyses indicated that on Venus, this concept could theoretically be used to produce cooling, but would not perform as well as a conventional heat pump. For environments other than Venus, the low theoretical performance limits general applicability of this concept, however this approach to cooling may be useful in niche applications. Analysis indicated that environments with particular atmospheric compositions and temperatures could allow a similar cooling system to operate with very good performance. This approach to cooling may also be useful where the products of reaction are also desirable, or for missions where design simplicity is valued. Conceptual designs for Venus cooling systems were developed using a modified concept, in which an expendable reactant supply would be used to promote more energetically favorable reactions with the ambient CO2, providing cooling for a more limited duration. This approach does not have the same performance issues, but the use of expendable supplies increases the mass requirements and limits the operating lifetime. This paper summarizes the findings of the literature search and corresponding analyses of the various cooling options.

  16. Superheated Water-Cooled Small Modular Underwater Reactor Concept

    Directory of Open Access Journals (Sweden)

    Koroush Shirvan

    2016-12-01

    Full Text Available A novel fully passive small modular superheated water reactor (SWR for underwater deployment is designed to produce 160 MWe with steam at 500ºC to increase the thermodynamic efficiency compared with standard light water reactors. The SWR design is based on a conceptual 400-MWe integral SWR using the internally and externally cooled annular fuel (IXAF. The coolant boils in the external channels throughout the core to approximately the same quality as a conventional boiling water reactor and then the steam, instead of exiting the reactor pressure vessel, turns around and flows downward in the central channel of some IXAF fuel rods within each assembly and then flows upward through the rest of the IXAF pins in the assembly and exits the reactor pressure vessel as superheated steam. In this study, new cladding material to withstand high temperature steam in addition to the fuel mechanical and safety behavior is investigated. The steam temperature was found to depend on the thermal and mechanical characteristics of the fuel. The SWR showed a very different transient behavior compared with a boiling water reactor. The inter-play between the inner and outer channels of the IXAF was mainly beneficial except in the case of sudden reactivity insertion transients where additional control consideration is required.

  17. Clarification and filtration of the floculated partuicles suspension from a chemical treatment of waste oil-in-water emulsions from a non-ferrous metalworking plant

    Directory of Open Access Journals (Sweden)

    Lazarević Vesna B.

    2011-01-01

    Full Text Available The effects of the coagulation/floculation conditions on clarification and filtration of the floculated particle suspension obtained by the chemical treatment of the waste oil-in-water emulsion (OWE from a non-ferrous metalworking plant were studied. The treatment involved the addition of aluminum(III sulfate and lime to the OWE. The main goal was to define the optimum conditions for clarification and filtration of the floculated particle suspension. The factors involved were amounts lime (i.e. pH and filter aid added the OWE on clarification and filtration rates. At pH>10, the clarification rate was increased and the final volume of the concentrated suspension (sludge was reduced, while filter aid affected negatively the clarification rate. The filtration rate was also increased when the coagulation was carried out at pH>10. The floculated particle suspension should be concentrated before filtration in order to decrease the filtration duration. The most efficient filter aid was Celite standard super-cel, its optimum initial concentration being found to be 2 g/dm3.

  18. Physical, chemical and mineralogical characterization of water treatment plant waste for use in soil-cement brick; Caracterizacao fisica, quimica e mineralogica de residuo de estacao de tratamento de aguas para aproveitamento em tijolo solo-cimento

    Energy Technology Data Exchange (ETDEWEB)

    Pessin, L.R.; Destefani, A.Z.; Holanda, J.N.F., E-mail: larapessin@hotmail.com [Universidade Estadual do Norte Fluminense Darcy Ribeiro (CCT/PPGECM/UENF), Campos dos Goytacazes, RJ (Brazil)

    2011-07-01

    The water treatment plants (WTP) for human consumption generate huge amounts of waste in the form of sludge (sludge) that have been over the years mostly inadequately prepared in water resources and the environment. Moreover, traditional methods of disposal of waste water treatment plants commonly used are generally costly activities. An alternative method for disposal of this waste abundant is its incorporation in ceramic products. This work is focused on the physical-chemical and mineralogical composition of a sample of waste water treatment plants from the region of Campos dos Goytacazes-RJ to their use in the manufacture of soil-cement brick. Several characterization techniques were used including X-ray diffraction, X-ray fluorescence, scanning electron microscopy, picnometry, particle size analysis and plasticity. The experimental results indicate that the waste water treatment plants have the potential to be used in the manufacture of ecologic soil-cement bricks. (author)

  19. Effect of Mixed Corrosion Inhibitors in Cooling Water System

    Directory of Open Access Journals (Sweden)

    Dina Raheem

    2011-01-01

    Full Text Available The effect of mixed corrosion inhibitors in cooling system was evaluated by using carbon steel specimens and weight loss analysis. The carbon steel specimens immersed in mixture of sodium phosphate (Na2 HPO4 used as corrosion inhibitor and sodium glocunate (C6 H11 NaO7 as a scale dispersant at different concentrations (20,40, 60, 80 ppm and at different temperature (25,50,75 and 100ºC for (1-5 days. The corrosion inhibitors efficiency was calculated by using uninhibited and inhibited water to give 98.1%. The result of these investigations indicate that the corrosion rate decreases with the increase the corrosion inhibitors concentration at 80 ppm and at 100ºC for 5 days, (i.e, corrosion rate= 0.014gmd.

  20. Costs of water treatment due to diminished water quality: A case study in Texas

    Science.gov (United States)

    Dearmont, David; McCarl, Bruce A.; Tolman, Deborah A.

    1998-04-01

    The cost of municipal water treatment due to diminished water quality represents an important component of the societal costs of water pollution. Here the chemical costs of municipal water treatment are expressed as a function of raw surface water quality. Data are used for a 3-year period for 12 water treatment plants in Texas. Results show that when regional raw water contamination is present, the chemical cost of water treatment is increased by 95 per million gallons (per 3785 m3) from a base of 75. A 1% increase in turbidity is shown to increase chemical costs by 0.25%.

  1. Study of the Al-Si-X system by different cooling rates and heat treatment

    Directory of Open Access Journals (Sweden)

    Miguel Angel Suarez

    2012-10-01

    Full Text Available The solidification behavior of the Al-12.6% Si (A1, the hypereutectic Al-20%Si (A2 and the Al-20%Si-1.5% Fe-0.5%Mn (A3 (in wt. (% alloys, at different cooling rates is reported and discussed. The cooling rates ranged between 0.93 °C/s and 190 °C/s when cast in sand and copper wedge-shaped molds, respectively. A spheroidization heat treatment was carried out to the alloys in the as-cast condition at 540 °C for 11 hours and quench in water with a subsequent heat treatment at 170 °C for 5 hours with the purpose of improving the mechanical properties. The samples were characterized by optical microscopy, scanning electron microscopy and mechanically by tensile test, in order to evaluate the response of the heat treatment on the different starting microstructures and mechanical properties. It was found that alloys cooled at rates greater than 10.8 °C/s had a smaller particle size and better distribution, also showed a greater response to spheroidization heat treatment of all silicon (Si phases. The spheroidization heat treatment caused an increase in the ultimate tensile stress (UTS and elongation when compared with the alloys in the as-cast condition. The highest UTS value of 174 MPa was obtained for the (A1 alloy.

  2. Overview of Cooling Water System for the KSTAR 1{sup st} Plasma Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. J.; Kim, S. T.; Im, D. S.; Joung, N. Y.; Kim, Y. S. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008.

  3. Outbreak of Legionnaires' disease from a cooling water system in a power station (Heysham)

    Energy Technology Data Exchange (ETDEWEB)

    Morton, S.; Dyer, J.V.; Bartlett, C.L.R.; Bibby, L.F.; Hutchinson, D.N.; Dennis, P.J.

    1986-09-01

    In September and October 1981 six cases of pneumonia occurred among men working in a power station under construction. Three were identified as cases of legionella pneumonia and two others had serology suggestive of legionella infection. In a sample of 92 men from the site 10 had low levels of antibodies to legionella; a similar sample of men working on an adjacent site showed none with positive serology. In a case control study it was found that cases of pneumonia were more likely than controls to have worked on a part of the site where four small capacity cooling towers were located. Legionella pneumophila serogroup 1 was isolated from the water systems of these four towers but was not found in samples from any other cooling towers or hot or cold water outlets on the site. It would appear that there was airborne spread of the organism from these cooling water systems which had not received conventional treatment to inhibit corrosion and organic growth. This is the first outbreak of legionnaires' disease to be recorded in an industrial setting in the United Kingdom. No cases of legionella infection have occurred on the site since the introduction of control measures.

  4. Treatment of TNT red water by physico-chemical and biological technologies%物化-生物组合工艺处理TNT红水

    Institute of Scientific and Technical Information of China (English)

    郝志; 叶正芳; 赵泉林

    2013-01-01

    The combination technology of acidification,micro-electrolysis,coagulating sedimentation,vacuum distillation,immobilized micro-organism and adsorption by activated coke (AC) was used to treat TNT red water generated from Xiangfan Division of 805 Factory.After treatment,the concentration of nitro compounds in effluent was lower than 0.8 mg/L,the average concentration of chemical oxygen demand (COD) was 51.6 mg/ L,with the mximum value of 76 mg/L,the chrominance was 20°,and the concentration of aminobenzene was lower than 1 mg/L.The values of these parameters reached the requirement of the factory,which are belowthe limits proposed by Chinese standard GB14470.1-2002 (Discharge Standard for Water Pollutants from Ordnance Industry:Powder and Explosive).During the period of the pilot scale test,the vacuum distillation apparatus operated stably,and no trouble of blocking and burning happened,meaning that treatment of TNT red water by vacuum distillation was safe and reliable.%采用酸析+微电解+混凝沉淀+减压蒸馏+固定化微生物滤池+活性焦吸附组合工艺处理兵器八○五厂(襄樊分部)的TNT红水,出水中的硝基化合物浓度多小于0.8 mg/L,且多次未检出;COD最高值为76 mg/L,平均值为51.6 mg/L;色度为20°;苯胺浓度全部小于1 mg/L,达到了中试方案提出的要求,出水水质指标符合《兵器工业水污染物排放标准火炸药》(GB14470.1-2002)的要求.中试期间设备没有发生堵塞、燃烧等事故,减压蒸馏装置正常稳定运行,证实了减压蒸馏法处理TNT红水的安全可靠性.

  5. Density of hydrophobically confined deeply cooled water investigated by small angle X-ray scattering

    Science.gov (United States)

    Liu, Kao-Hsiang; Zhang, Yang; Jeng, U.-Ser; Mou, Chung-Yuan

    2015-09-01

    Water's behavior near hydrophobic surfaces has attracted great attention due to chemical and geological applications. Here, we report small angle X-ray scattering (SAXS) studies of water confined in the hydrophobic nanoporous carbon material, CMK-1-14, from ambient to deeply cooled temperatures. By monitoring the scattering intensity of the first Bragg peak, which is directly related to the scattering length density contrast between the carbon matrix and the confined water, the average density of the hydrophobically confined water was determined from 300 K to 150 K at ambient pressure. Furthermore, differential scanning calorimetry and X-ray diffraction measurements showed that the majority of such hydrophobically confined water did not crystallize in the investigated temperature range. By exploiting the fast speed of SAXS measurements and the continuous temperature ramping, the average density profile and the deduced thermal expansion coefficient (αp) were obtained. We found that the well-known density maximum of water at 277 K downshifted to 260 K, and the density minimum which has been observed in hydrophilic confinement disappeared. In addition, the previously measured large density decreasing of 18% at low temperature was recalibrated to a more reasonable 10% instead. Consequently, the recalculated αp peak was found to be quite similar to that of the water confined in hydrophilic MCM-41-S-15 suggesting an intrinsic property of water, which does not sensitively depend on the confinement surface.

  6. Evaluation of alternative environmentally friendly matrix solid phase dispersion solid supports for the simultaneous extraction of 15 pesticides of different chemical classes from drinking water treatment sludge.

    Science.gov (United States)

    Soares, Karina Lotz; Cerqueira, Maristela Barnes Rodrigues; Caldas, Sergiane Souza; Primel, Ednei Gilberto

    2017-09-01

    This study describes the development, optimization and validation of a method for the extraction of 15 pesticides of different chemical classes in drinking water treatment sludge (DWTS) by vortex-assisted Matrix Solid Phase Dispersion (MSPD) with determination by gas chromatography coupled to mass spectrometry. It focused on the application of alternative and different solid supports to the extraction step of the MSPD. The main parameters that influenced the extraction were studied in order to obtain better recovery responses. Recoveries ranged from 70 to 120% with RSD below 20% for all analytes. Limits of quantification (LOQ) of the method ranged from 5 to 500 μg kg(-1) whereas the analytical curves showed correlation coefficients above 0.997. The method under investigation used low volume of solvent (5 mL), low sample mass (1.5 g) and low mass of chitin (0.5 g), an environmentally friendly support. It has advantages, such as speed, simplicity and low cost material, over other methods. When the method was applied, 4 out of 15 pesticides were detected in the DWTS samples in concentrations below the LOQ. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Development of the water cooled lithium lead blanket for DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Aubert, J., E-mail: julien.aubert@cea.fr [CEA-Saclay, DEN/DANS/DM2S/SEMT/BCCR, 91191 Gif Sur Yvette Cedex (France); Aiello, G.; Jonquères, N. [CEA-Saclay, DEN/DANS/DM2S/SEMT/BCCR, 91191 Gif Sur Yvette Cedex (France); Li Puma, A. [CEA-Saclay, DEN/DANS/DM2S/SERMA/LPEC, 91191 Gif Sur Yvette Cedex (France); Morin, A.; Rampal, G. [CEA-Saclay, DEN/DANS/DM2S/SEMT/BCCR, 91191 Gif Sur Yvette Cedex (France)

    2014-10-15

    Highlights: • The WCLL blanket design has been modified to adapt it to the 2012 EFDA DEMO specifications. • Preliminary CAD design of the equatorial outboard module of the WCLL blanket has been developed for DEMO. • Finite elements analyses have been carried out in order to assess the module thermal behavior in the straight part of the module. - Abstract: The water cooled lithium lead (WCLL) blanket, based on near-future technology requiring small extrapolation from present-day knowledge both on physical and technological aspect, is one of the breeding blanket concepts considered as possible candidates for the EU DEMOnstration power plant. In 2012, the EFDA agency issued new specifications for DEMO: this paper describes the work performed to adapt the WCLL blanket design to those specifications. Relatively small modules with straight surfaces are attached to a common Back Supporting Structure housing feeding pipes. Each module features reduced activation ferritic-martensitic steel as structural material, liquid Lithium-Lead as breeder, neutron multiplier and carrier. Water at typical Pressurized Water Reactors (PWR) conditions is chosen as coolant. A preliminary design of the equatorial outboard module has been achieved. Finite elements analyses have been carried out in order to assess the module thermal behavior. Two First Wall (FW) concepts have been proposed, one favoring the thermal efficiency, the other favoring the manufacturability. The Breeding Zone has been designed with C-shaped Double-Walled Tubes in order to minimize the Water/Pb-15.7Li interaction likelihood. The priorities for further development of the WCLL blanket concept are identified in the paper.

  8. CHEMICAL QUALITY CHARACTERISTICS OF TEHRAN GROUND WATER

    Directory of Open Access Journals (Sweden)

    K. Imandel

    1994-06-01

    Full Text Available For better understanding of Tehran ground water, samples were taken randomly from 340 out of 655 deep & semi deep wells in 1993, which dug by Tehran Water Supply and Sewage Engineering Company. 260 Water specimens were examined chemically and physically and compared with the 1993 World Health Organization (WHO and Food and Agriculture Organization (FAO criteria and analyzed statistically. Logarithmic diagram of arithmetic mean of 53 deep wells which are now connected to Tehran water supply system showed Sodium- Sulphate category. Main chemical components of water are closely adjusted to the international standards and no overdoses were observed in any cases. Logarithmic diagram of arithmetic mean of 72 deep wells, which were rsed for the Tehran’s orbital town's drinking water, showed that chemical components of the water were Calcic-Chloride category and there were not observed any increases within the other compounds.

  9. Treatment of Recirculating Cooling Water by Ion-exchange Micro-alkalizing Process for Approach Zero-discharge%循环冷却水离子交换微碱化趋零排放处理

    Institute of Scientific and Technical Information of China (English)

    曾惠明; 徐天有; 范蕊; 叶金华

    2015-01-01

    研究了趋零排放的敞开式循环冷却水离子交换微碱化处理工艺。小试和中试结果表明,铁质换热器选用强酸RNa型与强碱RHCO3型树脂串联工艺,黄铜换热器选用弱酸RH型、强酸RH型及弱碱ROH树脂串联,末端加入NaOH的处理工艺进行补水。可实现敞开式循环冷却水系统稳定运行和趋零排放,钙镁离子等结垢阳离子,氯根等加速金属腐蚀的阴离子被清除,系统中水质pH和碱度均可控, pH为8.0~9.5之间,碱度为6.0~12.0 mmol/L之间,可延缓金属腐蚀。%The process of the recirculating cooling water micro-alkalizing by ion-exchange resin was studied, which can approach zero discharge of waste water. The bench test and the pilot result indicated that, the heat exchanger made out of iron used the series connection process between RNa resin and RHCO3 resin with the makeup water treating. And the heat exchanger containing copper used the series connection process among RH weak acidic resin, RH strong acerbic resin and ROH weak anionic resin, with NaOH added in the outlet to adjust the alkalinity. The recirculating cooling water system kept stable and approach zero discharge of waste water in the process, at the same time, the scaling cation and the anion, such as chloride ion, had been removed, the pH and alkalinity can be adjusted precisely. The metal corrosion can be restrained when the pH was between 8. 0 and 9. 5 , the alkalinity was between 6 mmol/L and 12. 0 mmol/L.

  10. Marginal costs of water savings from cooling system retrofits: a case study for Texas power plants

    Science.gov (United States)

    Loew, Aviva; Jaramillo, Paulina; Zhai, Haibo

    2016-10-01

    The water demands of power plant cooling systems may strain water supply and make power generation vulnerable to water scarcity. Cooling systems range in their rates of water use, capital investment, and annual costs. Using Texas as a case study, we examined the cost of retrofitting existing coal and natural gas combined-cycle (NGCC) power plants with alternative cooling systems, either wet recirculating towers or air-cooled condensers for dry cooling. We applied a power plant assessment tool to model existing power plants in terms of their key plant attributes and site-specific meteorological conditions and then estimated operation characteristics of retrofitted plants and retrofit costs. We determined the anticipated annual reductions in water withdrawals and the cost-per-gallon of water saved by retrofits in both deterministic and probabilistic forms. The results demonstrate that replacing once-through cooling at coal-fired power plants with wet recirculating towers has the lowest cost per reduced water withdrawals, on average. The average marginal cost of water withdrawal savings for dry-cooling retrofits at coal-fired plants is approximately 0.68 cents per gallon, while the marginal recirculating retrofit cost is 0.008 cents per gallon. For NGCC plants, the average marginal costs of water withdrawal savings for dry-cooling and recirculating towers are 1.78 and 0.037 cents per gallon, respectively.

  11. Ecological impact of chloro-organics produced by chlorination of cooling tower waters

    Energy Technology Data Exchange (ETDEWEB)

    Jolley, R L; Cumming, R B; Pitt, W W; Taylor, F G; Thompson, J E; Hartmann, S J

    1977-01-01

    Experimental results of the initial assessment of chlorine-containing compounds in the blowdown from cooling towers and the possible mutagenic activity of these compounds are reported. High-resolution liquid chromatographic separations were made on concentrates of the blowdown from the cooling tower at the High Flux Isotope Reactor (HFIR) and from the recirculating water system for the cooling towers at the Oak Ridge Gaseous Diffusion Plant (ORGDP), Oak Ridge, Tennessee. The chromatograms of chlorinated cooling waters contained numerous uv-absorbing and cerate-oxidizable constituents that are now being processed through a multicomponent identification procedure. Concentrates of the chlorinated waters are also being examined for mutagenic activity.

  12. Water-cooled non-thermal gliding arc for adhesion improvement of glass-fibre-reinforced polyester

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Sørensen, Bent F.; Løgstrup Andersen, Tom;

    2013-01-01

    -fibre-reinforced polyester plates were treated using an atmospheric pressure gliding-arc discharge with air flow to improve adhesion with a vinylester adhesive. The electrodes were water-cooled so as to operate the gliding arc continually. The treatment improved wettability and increased the density of oxygen...

  13. Performance of materials in the component cooling water systems of pressurized water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B.S.

    1993-06-01

    The component cooling water (CCW) system provides cooling water to several important loads throughout the plant under all operating conditions. An aging assessment CCW systems in pressurized water reactors (PWRs) was conducted as part of Nuclear Plant Aging Research Program (NPAR) instituted by the US Nuclear Regulatory Commission. This paper presents some of the results on the performances of materials in respect of their application in CCW Systems. All the CCW system failures reported to the Nuclear Plant Reliability Data System (NPRDS) from January 1988 to June 1990 were reviewed; it is concluded that three of the main contributors to CCW system failures are valves, pumps, and heat exchangers. This study identified the modes and causes of failure for these components; most of the causes for the aging-related failures could be related to the performance of materials. Also, in this paper the materials used for these components are reviewed, and there aging mechanisms under CCW system conditions are discussed.

  14. Heat Transfer Analysis to Optimize The Water Cooling Scheme For Combustion Device

    Directory of Open Access Journals (Sweden)

    B. Usha Rani

    2014-08-01

    Full Text Available Thermal Propulsion system is one kind of propulsion system which is used to drive torpedo. The present study focuses mainly on design of combustion device known to be thrust chamber or thrust cylinder. The chamber and nozzle wall and the injector face plate must be made of metals selected for high strength at elevated temperature coupled with good thermal conductivity, resistance to high temperature oxidation. chemical inertness on the coolant on the coolant side, and suitability for the fabrication method to be employed. In the case of certain monopropellants, the metal must not catalyze the decomposition. Although aluminum and copper alloys have been used successfully for combustion chambers and nozzles, stainless steels and carbon steels are in widest use today.A cooling jacket permits the circulation of a coolant, which, in the case of flight engines is usually one of the propellants. Water is the only coolant recommended. The cooling jacket consists of an inner and outer wall. The combustion chamber forms the inner wall and another concentric but larger cylinder provides the outer wall. The space between the walls serves as the coolant passage. The nozzle throat region usually has the highest heat transfer intensity and is, therefore, the most difficult to cool.

  15. Water recycle treatment system for use in metal processing

    Energy Technology Data Exchange (ETDEWEB)

    Hewitt, D.E.; Dando, T.J.

    1976-08-10

    A water recycle treatment system is described comprising two main treatment sub-systems for treatment of contaminated water from a plurality of concentrated solutions and rinse baths to separate out the impurities therein. A first sub-system treats less concentrated solutions used for the rinse baths by channeling the flow therefrom to a first neutralizing tank which provides for pH control to produce a mixed output solution having a substantially constant pH factor, which is filtered to remove gross particles, the filtered solution being cooled in a holding tank and passed through a reverse osmosis process and carbon bed to produce clean water. The second sub-system treats highly concentrated solutions obtained from a plurality of chemical processes, mixes them in a second neutralizing tank which is utilized to produce a substantially constant pH output, which is fed to an evaporator to precipitate the metals and salts in sludge and also forms a water vapor output. The reverse osmosis waste is fed back into the second neutralizing tank and processed as noted above.

  16. Importance of analytically verifying chemical treatments

    Science.gov (United States)

    Rach, J.J.; Gaikowski, M.P.; Olson, J.J.

    1997-01-01

    Hydrogen peroxide is considered a low regulatory priority compound by the U.S. Food and Drug Administration. It is used to control fungal infections on fish eggs. We studied the treatment profiles of hydrogen peroxide in Heath, McDonald egg jar, and Clark-Williamson incubators during treatments intended to deliver an effective regimen of at least 500 ??L hydrogen peroxide/L (i.e., treatments of 500 and 1,000 ??L/L) for 15 min. Hydrogen peroxide concentrations decreased with increasing distance from the influent water in both Heath and Clark-Williamson incubators. The top treatment tray (tray 2) of the Heath incubator received more than 90% of the intended regimen during the 500 ??L/L treatment, whereas at 1,000 ??L/L, all trays had hydrogen peroxide concentrations at or above 500 ??L/L for 15 min. None of the compartments in the Clark-Williamson incubator received the intended therapeutic regimen when treated at 500 ??L/L. The McDonald egg jar system distributed the intended concentration for the designated treatment period in all jars, except those located directly below the influent water. Our results indicate that dilution of therapeutants applied through certain egg incubation systems significantly decreases the efficacy of treatments and may render them ineffective. The dilution characteristics of egg incubation systems should be assessed in order to ensure proper delivery of all intended chemical concentrations and exposure regimens. Suggestions for maintaining the minimum effective concentrations in evaluated incubators are included.

  17. Optimization of the breeder zone cooling tubes of the DEMO Water-Cooled Lithium Lead breeding blanket

    Energy Technology Data Exchange (ETDEWEB)

    Di Maio, P.A.; Arena, P.; Bongiovì, G. [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo, Viale delle Scienze, Palermo (Italy); Chiovaro, P., E-mail: pierluigi.chiovaro@unipa.it [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo, Viale delle Scienze, Palermo (Italy); Del Nevo, A. [ENEA Brasimone, Camugnano, BO (Italy); Forte, R. [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo, Viale delle Scienze, Palermo (Italy)

    2016-11-01

    Highlights: • Determination of an optimal configuration for the breeder zone cooling tubes. • Attention has been focused on the toroidal–radial breeder zone cooling tubes lay out. • A theoretical-computational approach based on the Finite Element Method (FEM) has been followed, adopting a qualified commercial FEM code. • Five different configurations have been investigated to optimize the breeder zone cooling tubes arrangement fulfilling all the rules prescribed by safety codes. - Abstract: The determination of an optimal configuration for the breeder zone (BZ) cooling tubes is one of the most important issues in the DEMO Water-Cooled Lithium Lead (WCLL) breeding blanket R&D activities, since BZ cooling tubes spatial distribution should ensure an efficient heat power removal from the breeder, avoiding hotspots occurrence in the thermal field. Within the framework of R&D activities supported by the HORIZON 2020 EUROfusion Consortium action on the DEMO WCLL breeding blanket design, a campaign of parametric analyses has been launched at the Department of Energy, Information Engineering and Mathematical Models of the University of Palermo (DEIM), in close cooperation with ENEA-Brasimone, in order to assess the potential influence of BZ cooling tubes number on the thermal performances of the DEMO WCLL outboard breeding blanket equatorial module under the nominal steady state operative conditions envisaged for it, optimizing their geometric configuration and taking also into account that a large number of cooling pipes can deteriorate the tritium breeding performances of the module. In particular, attention has been focused on the toroidal-radial option for the BZ tube bundles lay-out and a parametric study has been carried out taking into account different tube bundles arrangement within the module. The study has been carried out following a numerical approach, based on the finite element method (FEM), and adopting a qualified commercial FEM code. Results

  18. State waste discharge permit application for cooling water and condensate discharges

    Energy Technology Data Exchange (ETDEWEB)

    Haggard, R.D.

    1996-08-12

    The following presents the Categorical State Waste Discharge Permit (SWDP) Application for the Cooling Water and Condensate Discharges on the Hanford Site. This application is intended to cover existing cooling water and condensate discharges as well as similar future discharges meeting the criteria set forth in this document.

  19. Cooling of Water in a Flask: Convection Currents in a Fluid with a Density Maximum

    Science.gov (United States)

    Velasco, S.; White, J. A.; Roman, F. L.

    2010-01-01

    The effect of density inversion on the convective flow of water in a spherical glass flask cooled with the help of an ice-water bath is shown. The experiment was carried out by temperature measurements (cooling curves) taken at three different heights along the vertical diameter of the flask. Flows inside the flask are visualized by seeding the…

  20. Cooling of Water in a Flask: Convection Currents in a Fluid with a Density Maximum

    Science.gov (United States)

    Velasco, S.; White, J. A.; Roman, F. L.

    2010-01-01

    The effect of density inversion on the convective flow of water in a spherical glass flask cooled with the help of an ice-water bath is shown. The experiment was carried out by temperature measurements (cooling curves) taken at three different heights along the vertical diameter of the flask. Flows inside the flask are visualized by seeding the…

  1. Multi-model assessment of global hydropower and cooling water discharge potential under climate change

    NARCIS (Netherlands)

    van Vliet, M. T H; van Beek, L. P H; Eisner, S.; Flörke, M.; Wada, Y.; Bierkens, M. F P

    2016-01-01

    Worldwide, 98% of total electricity is currently produced by thermoelectric power and hydropower. Climate change is expected to directly impact electricity supply, in terms of both water availability for hydropower generation and cooling water usage for thermoelectric power. Improved understanding

  2. Thermal behaviour analysis on ITER component cooling water system loop 2B

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Bin, E-mail: guobin@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Fu, Peng [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Dell’Orco, Giovanni; Liliana, Teodoros; Tao, Jun [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Yang, Lei [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2015-11-15

    Highlights: • Thermal hydraulic analysis model has been developed to perform thermal analysis on the component cooling water system loop 2B. • The cooling water temperature profile at client inlet and outlet during one cycle of the most demanding plasma operation scenario was obtained. • Operation behaviour of the main heat exchanger for CCWS-2B has been depicted. - Abstract: ITER cooling water system is composed by several cooling loops, the primary heat transfer loops that form the Tokamak Cooling Water System (TCWS), the secondary heat transfer loops that form the Component Cooling Water System (CCWS) and the Chilled Water System (CHWS) and a tertiary heat transfer loop which is the Heat Rejection System (HRS). The CCWS is further divided into CCWS-1, CCWS-2A, CCWS-2B, CCWS-2C, CCWS-2D depending on the water chemistry needs of clients and wetted area material. The component cooling water system loop 2B (CCWS-2B) has the function to remove heat load from coil power supply component, Neutral Beam Injectors (NBIs) system component and diagnostic system which are located in different buildings. As the total number of the client connections for the loop is a few hundreds, simplified thermal hydraulic analysis model has been developed to perform thermal analysis on the component cooling water system loop 2B. The curve of the cooling water temperature at client inlet and outlet during one cycle of the most demanding plasma operation scenario was obtained and the cooling water flow rate can meet the thermal removal requirement of client was also confirmed from this analysis. In addition, operation behaviour of the main heat exchanger for CCWS-2B in this thermal analysis was depicted for main heat exchanger selection purposes. This study has been carried out with the AFT Fathom code.

  3. Zirconium carbide coating for corium experiments related to water-cooled and sodium-cooled reactors

    Science.gov (United States)

    Plevacova, K.; Journeau, C.; Piluso, P.; Zhdanov, V.; Baklanov, V.; Poirier, J.

    2011-07-01

    Since the TMI and Chernobyl accidents the risk of nuclear severe accident is intensively studied for existing and future reactors. In case of a core melt-down accident in a nuclear reactor, a complex melt, called corium, forms. To be able to perform experiments with prototypic corium materials at high temperature, a coating which resists to different corium melts related to Generation I and II Water Reactors and Generation IV sodium fast reactor was researched in our experimental platforms both in IAE NNC in Kazakhstan and in CEA in France. Zirconium carbide was selected as protective coating for graphite crucibles used in our induction furnaces: VCG-135 and VITI. The method of coating application, called reactive wetting, was developed. Zirconium carbide revealed to resist well to the (U x, Zr y)O 2-z water reactor corium. It has also the advantage not to bring new elements to this chemical system. The coating was then tested with sodium fast reactor corium melts containing steel or absorbers. Undesirable interactions were observed between the coating and these materials, leading to the carburization of the corium ingots. Concerning the resistance of the coating to oxide melts without ZrO 2, the zirconium carbide coating keeps its role of protective barrier with UO 2-Al 2O 3 below 2000 °C but does not resist to a UO 2-Eu 2O 3 mixture.

  4. Physical/chemical closed-loop water-recycling

    Science.gov (United States)

    Herrmann, Cal C.; Wydeven, Theodore

    1991-01-01

    Water needs, water sources, and means for recycling water are examined in terms appropriate to the water quality requirements of a small crew and spacecraft intended for long duration exploration missions. Inorganic, organic, and biological hazards are estimated for waste water sources. Sensitivities to these hazards for human uses are estimated. The water recycling processes considered are humidity condensation, carbon dioxide reduction, waste oxidation, distillation, reverse osmosis, pervaporation, electrodialysis, ion exchange, carbon sorption, and electrochemical oxidation. Limitations and applications of these processes are evaluated in terms of water quality objectives. Computerized simulation of some of these chemical processes is examined. Recommendations are made for development of new water recycling technology and improvement of existing technology for near term application to life support systems for humans in space. The technological developments are equally applicable to water needs on Earth, in regions where extensive water recycling is needed or where advanced water treatment is essential to meet EPA health standards.

  5. Steam-Reheat Option for Supercritical-Water-Cooled Reactors

    Science.gov (United States)

    Saltanov, Eugene

    SuperCritical-Water-cooled Reactors (SCWRs) are being developed as one of the Generation-IV nuclear-reactor concepts. Main objectives of the development are to increase thermal efficiency of a Nuclear Power Plant (NPP) and to decrease capital and operational costs. The first objective can be achieved by introducing nuclear steam reheat inside a reactor and utilizing regenerative feedwater heaters. The second objective can be achieved by designing a steam cycle that closely matches that of the mature supercritical fossil-fuelled power plants. The feasibility of these objectives is discussed. As a part of this discussion, heat-transfer calculations have been performed and analyzed for SuperCritical-Water (SCW) and SuperHeated-Steam (SHS) channels of the proposed reactor concept. In the calculations a uniform and three non-uniform Axial Heat Flux Profiles (AHFPs) were considered for six different fuels (UO2, ThO 2, MOX, UC2, UC, and UN) and at average and maximum channel power. Bulk-fluid, sheath, and fuel centerline temperatures as well as the Heat Transfer Coefficient (HTC) profiles were obtained along the fuel-channel length. The HTC values are within a range of 4.7--20 kW/m2·K and 9.7--10 kW/m2·K for the SCW and SHS channels respectively. The main conclusion is that while all the mentioned fuels may be used for the SHS channel, only UC2, UC, or UN are suitable for a SCW channel, because their fuel centerline temperatures are at least 1000°C below melting point, while that of UO2, ThO2 , and MOX may reach melting point.

  6. Control of cross-infection risks in the dental operatory: prevention of water retraction by bur cooling spray systems.

    Science.gov (United States)

    Crawford, J J; Broderius, C

    1988-05-01

    A new dental unit control system was found to overcome the possibility of mechanically retracting bacteria from the mouth into the water line used to provide a spray of water to cool high-speed burs during treatments. This was demonstrated by results obtained after clinical use and after use in simulated, worst case test conditions using a red tempera indicator solution and indicator bacteria.

  7. The cool shopping centre of the Netherlands. The realization of four cooling units in Utrecht, Netherlands; Het koele winkelhart van Nederland. Realisatie vier koudecentrales in Utrecht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-01

    A brief description is given of a project to install four cooling machines (absorption cooling, compression cooling, cooling towers, and water treatment units) in the office and shopping centre Hoog Catharijne in Utrecht, Netherlands. 3 ills., 1 tab.

  8. District cool water distribution; Reseau urbain et distribution d`eau glacee

    Energy Technology Data Exchange (ETDEWEB)

    Schabaillie, D. [Ste Climespace (France)

    1997-12-31

    The city of Paris has developed several district cool water distribution networks (Climespace) for air conditioning purposes, one in the Halles district (central Paris) linked with the Louvre museum, one in the Opera district (with large department stores) and one in the east of paris (Bercy). Each of these networks has a cool water production plant, the one at the Halles producing also hot water and safety electric power. The characteristics of the equipment (heat pumps, refrigerating machinery, storage...) are described. The pipes are laid in the city sewage network, and the cool carrier is water. The various networks are centrally supervised at the Halles center

  9. USE OF PRODUCED WATER IN RECIRCULATING COOLING SYSTEMS AT POWER GENERATING FACILITIES

    Energy Technology Data Exchange (ETDEWEB)

    Michael N. DiFilippo

    2004-08-01

    The purpose of this study is to evaluate produced water as a supplemental source of water for the San Juan Generating Station (SJGS). This study incorporates elements that identify produced water volume and quality, infrastructure to deliver it to SJGS, treatment requirements to use it at the plant, delivery and treatment economics, etc. SJGS, which is operated by Public Service of New Mexico (PNM) is located about 15 miles northwest of Farmington, New Mexico. It has four units with a total generating capacity of about 1,800 MW. The plant uses 22,400 acre-feet of water per year from the San Juan River with most of its demand resulting from cooling tower make-up. The plant is a zero liquid discharge facility and, as such, is well practiced in efficient water use and reuse. For the past few years, New Mexico has been suffering from a severe drought. Climate researchers are predicting the return of very dry weather over the next 30 to 40 years. Concern over the drought has spurred interest in evaluating the use of otherwise unusable saline waters. Deliverable 2 focuses on transportation--the largest obstacle to produced water reuse in the San Juan Basin (the Basin). Most of the produced water in the Basin is stored in tanks at the well head and must be transported by truck to salt water disposal (SWD) facilities prior to injection. Produced water transportation requirements from the well head to SJGS and the availability of existing infrastructure to transport the water are discussed in this deliverable.

  10. Effect of conventional chemical treatment on the microbial

    NARCIS (Netherlands)

    Bereschenko, L.A.; Prummel, H.; Euverink, G.J.W.; Stams, A.J.M.; Loosdrecht, M.C.M. van

    2011-01-01

    The impact of conventional chemical treatment on initiation and spatiotemporal development of biofilms on reverse osmosis (RO) membranes was investigated in situ using flow cells placed in parallel with the RO system of a full-scale water treatment plant. The flow cells got the same feed (extensivel

  11. Corrosion of metals and alloys - Corrosion and fouling in industrial cooling water systems - Part 1: Guidelines for conducting pilot-scale evaluation of corrosion and fouling control additives for open recirculating cooling water systems

    CERN Document Server

    International Organization for Standardization. Geneva

    2006-01-01

    Corrosion of metals and alloys - Corrosion and fouling in industrial cooling water systems - Part 1: Guidelines for conducting pilot-scale evaluation of corrosion and fouling control additives for open recirculating cooling water systems

  12. COOLING WATER ISSUES AND OPPORTUNITIES AT U.S. NUCLEAR POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    Gary Vine

    2010-12-01

    This report has been prepared for the Department of Energy, Office of Nuclear Energy (DOE-NE), for the purpose of providing a status report on the challenges and opportunities facing the U.S. commercial nuclear energy industry in the area of plant cooling water supply. The report was prompted in part by recent Second Circuit and Supreme Court decisions regarding cooling water system designs at existing thermo-electric power generating facilities in the U.S. (primarily fossil and nuclear plants). At issue in the courts have been Environmental Protection Agency regulations that define what constitutes “Best Technology Available” for intake structures that withdraw cooling water that is used to transfer and reject heat from the plant’s steam turbine via cooling water systems, while minimizing environmental impacts on aquatic life in nearby water bodies used to supply that cooling water. The report was also prompted by a growing recognition that cooling water availability and societal use conflicts are emerging as strategic energy and environmental issues, and that research and development (R&D) solutions to emerging water shortage issues are needed. In particular, cooling water availability is an important consideration in siting decisions for new nuclear power plants, and is an under-acknowledged issue in evaluating the pros and cons of retrofitting cooling towers at existing nuclear plants. Because of the significant ongoing research on water issues already being performed by industry, the national laboratories and other entities, this report relies heavily on ongoing work. In particular, this report has relied on collaboration with the Electric Power Research Institute (EPRI), including its recent work in the area of EPA regulations governing intake structures in thermoelectric cooling water systems.

  13. Optimal Environmental Performance of Water-cooled Chiller System with All Variable Speed Configurations

    Science.gov (United States)

    Yu, Fu Wing; Chan, Kwok Tai

    This study investigates how the environmental performance of water-cooled chiller systems can be optimized by applying load-based speed control to all the system components. New chiller and cooling tower models were developed using a transient systems simulation program called TRNSYS 15 in order to assess the electricity and water consumption of a chiller plant operating for a building cooling load profile. The chiller model was calibrated using manufacturer's performance data and used to analyze the coefficient of performance when the design and control of chiller components are changed. The NTU-effectiveness approach was used for the cooling tower model to consider the heat transfer effectiveness at various air-to-water flow ratios and to identify the makeup water rate. Applying load-based speed control to the cooling tower fans and pumps could save an annual plant operating cost by around 15% relative to an equivalent system with constant speed configurations.

  14. Three African antelope species with varying water dependencies exhibit similar selective brain cooling.

    Science.gov (United States)

    Strauss, W Maartin; Hetem, Robyn S; Mitchell, Duncan; Maloney, Shane K; Meyer, Leith C R; Fuller, Andrea

    2016-05-01

    The use of selective brain cooling, where warm arterial blood destined for the brain is cooled in the carotid rete via counter-current heat exchange when in close proximity to cooler venous blood, contributes to the conservation of body water. We simultaneously measured carotid blood and hypothalamic temperature in four gemsbok, five red hartebeest and six blue wildebeest to assess the extent to which these free-living animals, with varying water dependency, routinely rely on selective brain cooling. We investigated the hypothesis that innate differences in selective brain cooling exist in large, sympatric artiodactyls with varying water dependency. All three species used selective brain cooling, without any discernible differences in three selective brain cooling indices. GLMMs revealed no species differences in the threshold temperature for selective brain cooling (z = 0.79, P = 0.43), the magnitude (z = -0.51, P = 0.61), or the frequency of selective brain cooling use (z = -0.47, P = 0.64), after controlling for carotid blood temperature and black globe temperature. Comparison of anatomical attributes of the carotid retes of the three species revealed that the volume (F 2,9 = 5.54, P = 0.03) and height (F 2,9 = 5.43, P = 0.03) of the carotid rete, per kilogram body mass, were greater in the red hartebeest than in the blue wildebeest. Nevertheless, intraspecific variability in the magnitude, the frequency of use, and the threshold temperature for selective brain cooling exceeded any interspecific variability in the three indices of selective brain cooling. We conclude that the three species have similar underlying ability to make use of selective brain cooling in an environment with freely available water. It remains to be seen to what extent these three species would rely on selective brain cooling, as a water conservation mechanism, when challenged by aridity, a condition likely to become prevalent throughout much of southern Africa under future climate change

  15. Thermal design of lithium bromide-water solution vapor absorption cooling system for indirect evaporative cooling for IT pod

    Science.gov (United States)

    Sawant, Digvijay Ramkrishna

    Nowadays with increase use of internet, mobile there is increase in heat which ultimately increases the efficient cooling system of server room or IT POD. Use of traditional ways of cooling system has ultimately increased CO2 emission and depletion of CFC's are serious environmental issues which led scientific people to improve cooling techniques and eliminate use of CFC's. To reduce dependency on fossil fuels and 4environmental friendly system needed to be design. For being utilizing low grade energy source such as solar collector and reducing dependency on fossil fuel vapour absorption cooling system has shown a great driving force in today's refrigeration systems. This LiBr-water aabsorption cooling consists of five heat exchanger namely: Evaporator, Absorber, Solution Heat Exchanger, Generator, Condenser. The thermal design was done for a load of 23 kW and the procedure was described in the thesis. There are 120 servers in the IT POD emitting 196 W of heat each on full load and some of the heat was generated by the computer placed inside the IT POD. A detailed procedure has been discussed. A excel spreadsheet was to prepared with varying tube sizes to see the effect on flows and ultimately overall heat transfer coefficient.

  16. Evaluation of the suitabil[i]ty of Fischer-Tropsch gas-to-liquid (GTL) Primary Column Bottoms as process cooling water : analysis of microbial community dynamics, fouling, scaling and corrosion / Savia Susanna Slabbert

    OpenAIRE

    Slabbert, Savia Susanna

    2007-01-01

    Water in South Africa is becoming limiting due to economic growth, social development and the country's water demand that exceed its water availability. Water conservation in the industry can be accomplished by the reuse of process water instead of direct treatment and discharge. By reusing a process effluent as cooling water in cooling towers, the water requirements of an industry, such as Sasol, will be lower and a zero effluent discharge scenario could be achieved. At Sas...

  17. Basic Concepts of Magnetic Water Treatment

    Directory of Open Access Journals (Sweden)

    Oleg Mosin

    2014-06-01

    Full Text Available This review article outlines an overview of new trends and modern approaches for practical implementation of magnetic water treatment to eliminate scaling salts (carbonate, chloride and sulfate salts of Ca2+, Mg2+, Fe2+ and Fe3+ cations in power heat-exchanger devices and pipe lines. The principles of physical effects of the magnetic field on H2O molecules as well as the parameters of physico-chemical processes occurring in water and the behavior of the dissolved in water scaling salts subjected to the magnetic treatment are discussed. It is demonstrated that the effect of the magnetic field on water is a complex multifactorial phenomenon resulted in changes of the structure of hydrated ions as well as the physico-chemical properties and behavior of dissolved inorganic salts, changes in the rate of electrochemical coagulation and aggregate stability (clumping and consolidation, formation of multiple nucleation sites on the particles of fine dispersed precipitate consisting of crystals of substantially uniform size. There are also submitted data on constructive features of various magnetic water treatment devices produced by domestic industry, based on the permanent magnets and electromagnets (solenoids, such as hydro magnetic systems (HMS, magnetic transducers (MT and magnetic activators (MA of water. It was estimated the efficiency of using the various magnetic water treatment devices in water treatment technologies.

  18. Conceptual design of a passive moderator cooling system for a pressure tube type natural circulation boiling water cooled reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Mukesh [Reactor Engineering Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Pal, Eshita, E-mail: eshi.pal@gmail.com [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094 (India); Nayak, Arun K.; Vijayan, Pallipattu K. [Reactor Engineering Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India)

    2015-09-15

    Highlights: • Passive moderator cooling system is designed to cool moderator passively during SBO. • PMCS is a system of two natural circulation loops, coupled via a heat exchanger. • RELAP5 analyses show that PMCS maintains moderator within safe limits for 7 days. - Abstract: The recent Fukushima accident has raised strong concern and apprehensions about the safety of reactors in case of a prolonged Station Black Out (SBO) continuing for several days. In view of this, a detailed study was performed simulating this condition in Advanced Heavy Water Reactor. In this study, a novel concept of moderator cooling by passive means has been introduced in the reactor design. The Passive Moderator Cooling System (PMCS) consists of a shell and tube heat exchanger designed to remove 2 MW heat from the moderator inside Calandria. The heat exchanger is located at a suitable elevation from the Calandria of the reactor, such that the hot moderator rises due to buoyancy into the heat exchanger and upon cooling from shell side water returns to Calandria forming a natural circulation loop. The shell side of the heat exchanger is also a natural circulation loop connected to an overhead large water reservoir, namely the GDWP. The objective of the PMCS is to remove the heat from the moderator in case of an SBO and maintaining its temperature below the permissible safe limit (100 °C) for at least 7 days. The paper first describes the concept of the PMCS. The concept has been assessed considering a prolonged SBO for at least 7 days, through an integrated analysis performed using the code RELAP5/MOD3.2 considering all the major components of the reactor. The analysis shows that the PMCS is able to maintain the moderator temperature below boiling conditions for 7 days.

  19. Cooling water system thermal performance analysis using the COCO computer code

    Energy Technology Data Exchange (ETDEWEB)

    Hom, J.; Jakub, R.M.; Durkosh, D.E. [Westinghouse Electric Corp., Pittsburgh, PA (United States). Energy Systems Business Unit

    1996-10-01

    Westinghouse Energy Systems Business Unit (ESBU) has worked with electric utility personnel to analyze the thermal performance of essential cooling water systems at nuclear generating stations. The primary goal of these analyses has been to demonstrate the operability of the cooling water systems during postulated limiting post-accident operation. In previous cooling water system thermal analyses, peak containment operating conditions were generally used as input assuming steady-state conditions. This approach is conservative as it does not take into account the improvement in containment conditions and cooling water system temperatures over time. This approach can, also, lead to an inconsistent set of assumptions between the two distinct analyses which may result in overly conservative calculated system operating conditions. These conditions inevitably impose unnecessary restrictions on cooling water system operation. Over the last few years, Westinghouse ESBU has coupled both the containment integrity and the cooling water system thermal calculations into an integrated analysis. This allows the use of a consistent set of input parameters and assumptions in the calculation of limiting cooling water system operating conditions. This approach has been successfully used to increase system operating margins. This paper provides an overview of this coupled thermal analysis along with examples of where increased operating margins can be applied.

  20. Cooling Rates of Humans in Air and in Water: An Experiment

    Science.gov (United States)

    Bohren, Craig F.

    2012-12-01

    In a previous article I analyzed in detail the physical factors resulting in greater cooling rates of objects in still water than in still air, emphasizing cooling of the human body. By cooling rate I mean the rate of decrease of core temperature uncompensated by metabolism. I concluded that the "correct ratio for humans is closer to 2 than to 10." To support this assertion I subsequently did experiments, which I report following a digression on hypothermia.

  1. Radiant Cooling for Closed-Loop Water Containment: Exploration of Possible Application in Dry Docks

    Science.gov (United States)

    2015-08-20

    Radiant Cooling For Closed-Loop Water Containment: Exploration of Possible Application in Dry Docks by Trevor R. Murphy, Mechanical...Organization: SPAWAR Sponsoring Organization: NESDI Keywords: Dry Dock Cooling, Heat Transfer, Closed Loop, Pipe System, Cost, Pareto List of Programs...provide data for estimating the cost of implementing a closed-loop radiant cooling system for ships in dry docks . Depending on the material used, pipe

  2. Polyfluorinated chemicals in European surface waters, ground- and drinking waters

    NARCIS (Netherlands)

    Eschauzier, C.; de Voogt, P.; Brauch, H.-J.; Lange, F.T.; Knepper, T.P.; Lange, F.T.

    2012-01-01

    Polyfluorinated chemicals (PFCs), especially short chain fluorinated alkyl sulfonates and carboxylates, are ubiquitously found in the environment. This chapter aims at giving an overview of PFC concentrations found in European surface, ground- and drinking waters and their behavior during convention

  3. Polyfluorinated chemicals in European surface waters, ground- and drinking waters

    NARCIS (Netherlands)

    Eschauzier, C.; de Voogt, P.; Brauch, H.-J.; Lange, F.T.; Knepper, T.P.; Lange, F.T.

    2012-01-01

    Polyfluorinated chemicals (PFCs), especially short chain fluorinated alkyl sulfonates and carboxylates, are ubiquitously found in the environment. This chapter aims at giving an overview of PFC concentrations found in European surface, ground- and drinking waters and their behavior during

  4. Water source heat pumps for greenhouse soil cooling. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Spieser, H.

    1987-06-01

    In an attempt to diversify and grow flowers which are in high demand, growers are looking to produce certain exotic flowers which require unique growing conditions. One example is the Alstroemerias also knwon as the Peruvian Lily. If the plants are grown continuously at about 12-15/sup 0/C soil temperature, the plant will continue to flower regardless of air temperature and photoriod. These latter two factors are considered secondary to the importance of cool soil temperatures. Alstroemeria production is still relatively new to the greenhouse industry. Some controversy still exists as to the direct benefits of planned soil cooling. This project was set up to evaluate a mechanical soil cooling system for continuous year round Alstroemeria production. A heat pump soil cooling system was installed in two greenhouses each with dimensions of 16 m by 61 m. Combined these greenhouses have a growing area of 1952 m/sup 2/. These greenhouses are older wooden greenhouses, covered by double poly, air-inflated glazing. This system worked very well, maintaining the soil temperature at the proper levels throughout the spring and summer months. During the rest of the year the soil cooling system is used less intensely. During winter months when soil cooling is not required, the heat pumps provide base load heating to the greenhouse through fan forced unit heaters.

  5. Accident analysis of heavy water cooled thorium breeder reactor

    Science.gov (United States)

    Yulianti, Yanti; Su'ud, Zaki; Takaki, Naoyuki

    2015-04-01

    Thorium has lately attracted considerable attention because it is accumulating as a by-product of large scale rare earth mining. The objective of research is to analyze transient behavior of a heavy water cooled thorium breeder that is designed by Tokai University and Tokyo Institute of Technology. That is oxide fueled, PWR type reactor with heavy water as primary coolant. An example of the optimized core has relatively small moderator to fuel volume ratio (MFR) of 0.6 and the characteristics of the core are burn-up of 67 GWd/t, breeding ratio of 1.08, burn-up reactivity loss during cycles of nuclear reactor accidents types examined here is Unprotected Transient over Power (UTOP) due to withdrawing of the control rod that result in the positive reactivity insertion so that the reactor power will increase rapidly. Another accident type is Unprotected Loss of Flow (ULOF) that caused by failure of coolant pumps. To analyze the reactor accidents, neutron distribution calculation in the nuclear reactor is the most important factor. The best expression for the neutron distribution is the Boltzmann transport equation. However, solving this equation is very difficult so that the space-time diffusion equation is commonly used. Usually, space-time diffusion equation is solved by employing a point kinetics approach. However, this approach is less accurate for a spatially heterogeneous nuclear reactor and the nuclear reactor with quite large reactivity input. Direct method is therefore used to solve space-time diffusion equation which consider spatial factor in detail during nuclear reactor accident simulation. Set of equations that obtained from full implicit finite-difference method is solved by using iterative methods. The indication of UTOP accident is decreasing macroscopic absorption cross-section that results large external reactivity, and ULOF accident is indicated by decreasing coolant flow. The power reactor has a peak value before reactor has new balance condition

  6. Synthesis and chemical modification of polymeric resins for the treatment of cations and aromatic hydrocarbons in produced oily water; Sintese de modificacao quimica de resina polimerica e aplicacao na remocao de cations e hidrocarbonetos aromaticos presentes em agua produzida

    Energy Technology Data Exchange (ETDEWEB)

    Aversa, Thiago M.; Rodrigues, Monique F.; Vieira, Helida V.P.; Queiros, Yure G.C.; Lucas, Elizabete F. [Universidade Federal do Rio de Janeiro, Instituto de Macromoleculas, Lab. de Macromoleculas e Coloides na Industria do Petroleo, Rio de Janeiro, RJ (Brazil)], e-mail: thiagoaversa@ima.ufrj.br

    2011-07-01

    The use of chemically modified resins in oily water treatment process is not very developed yet. Because of this, this work suggests to study the styrene and divinylbenzene sulfonation effect on oil and grease, aniline and calcium removal from the water. The aniline, oils and greases belong to a class of toxic organic compounds, with the Brazilian maximum limits established for disposal in CONAMA 393/2007, while the calcium ions belong to the group of cations of alkaline earth metals which improve hardness to the water, may cause fouling as carbonates and sulfates form. By using sulfonated resins in oily water treatment it is possible to remove not only oils and greases but also calcium and aniline. These kinds of polar compounds are removed because of the cation exchange capacity of resin. (author)

  7. Influence of Chlorination and Choice of Materials on Fouling in Cooling Water System under Brackish Seawater Conditions

    Directory of Open Access Journals (Sweden)

    Pauliina Rajala

    2016-06-01

    Full Text Available Cooling systems remove heat from components and industrial equipment. Water cooling, employing natural waters, is typically used for cooling large industrial facilities, such as power plants, factories or refineries. Due to moderate temperatures, cooling water cycles are susceptible to biofouling, inorganic fouling and scaling, which may reduce heat transfer and enhance corrosion. Hypochlorite treatment or antifouling coatings are used to prevent biological fouling in these systems. In this research, we examine biofouling and materials’ degradation in a brackish seawater environment using a range of test materials, both uncoated and coated. The fouling and corrosion resistance of titanium alloy (Ti-6Al-4V, super austenitic stainless steel (254SMO and epoxy-coated carbon steel (Intershield Inerta160 were studied in the absence and presence of hypochlorite. Our results demonstrate that biological fouling is intensive in cooling systems using brackish seawater in sub-arctic areas. The microfouling comprised a vast diversity of bacteria, archaea, fungi, algae and protozoa. Chlorination was effective against biological fouling: up to a 10–1000-fold decrease in bacterial and archaeal numbers was detected. Chlorination also changed the diversity of the biofilm-forming community. Nevertheless, our results also suggest that chlorination enhances cracking of the epoxy coating.

  8. Heat transfer enhancement in a natural draft dry cooling tower under crosswind operation with heterogeneous water distribution

    Energy Technology Data Exchange (ETDEWEB)

    Goodarzi, Mohsen; Amooie, Hossein [Bu-Ali Sina Univ., Hamedan (Iran, Islamic Republic of). Dept. of Mechanical Engineering

    2016-04-15

    Crosswind significantly decreases cooling efficiency of a natural draft dry cooling tower. The possibility of improving cooling efficiency with heterogeneous water distribution within the cooling tower radiators under crosswind condition is analysed. A CFD approach was used to model the flow field and heat transfer phenomena within the cooling tower and airflow surrounding the cooling tower. A mathematical model was developed from various CFD results. Having used a trained Genetic Algorithm with the result of mathematical model, the best water distribution was found among the others. Remodeling the best water distribution with the CFD approach showed that the highest enhancement of the heat transfer compared to the usual uniform water distribution.

  9. Comparison of solar panel cooling system by using dc brushless fan and dc water

    Science.gov (United States)

    Irwan, Y. M.; Leow, W. Z.; Irwanto, M.; M, Fareq; Hassan, S. I. S.; Safwati, I.; Amelia, A. R.

    2015-06-01

    The purpose of this article is to discuss comparison of solar panel cooling system by using DC brushless fan and DC water pump. Solar photovoltaic (PV) power generation is an interesting technique to reduce non-renewable energy consumption and as a renewable energy. The temperature of PV modules increases when it absorbs solar radiation, causing a decrease in efficiency. A solar cooling system is design, construct and experimentally researched within this work. To make an effort to cool the PV module, Direct Current (DC) brushless fan and DC water pump with inlet/outlet manifold are designed for constant air movement and water flow circulation at the back side and front side of PV module representatively. Temperature sensors were installed on the PV module to detect temperature of PV. PIC microcontroller was used to control the DC brushless fan and water pump for switch ON or OFF depend on the temperature of PV module automatically. The performance with and without cooling system are shown in this experiment. The PV module with DC water pump cooling system increase 3.52%, 36.27%, 38.98%in term of output voltage, output current, output power respectively. It decrease 6.36 °C compare than to PV module without DC water pump cooling system. While DC brushless fan cooling system increase 3.47%, 29.55%, 32.23%in term of output voltage, output current, and output power respectively. It decrease 6.1 °C compare than to PV module without DC brushless fan cooling system. The efficiency of PV module with cooling system was increasing compared to PV module without cooling system; this is because the ambient temperature dropped significantly. The higher efficiency of PV cell, the payback period of the system can be shorted and the lifespan of PV module can also be longer.

  10. Water mist effect on cooling range and efficiency of casting die

    Directory of Open Access Journals (Sweden)

    R. Władysiak

    2008-12-01

    Full Text Available This project is showing investigation results of cooling process of casting die in the temperature range 570÷100 °C with 0.40 MPa compressed air and water mist streamed under pressure 0.25÷0.45 MPa in air jet 0.25÷0.50 MPa using open cooling system.The character and the speed of changes of temperature, forming of the temperture’s gradient along parallel layer to cooled surface of die is shawing with thermal and derivative curves. The effect of kind of cooling factor on the temperature and time and distance from cooling nozzle is presented in the paper. A designed device for generating the water mist cooling the die and the view of sprying water stream is shown here. It’s proved that using of the water mist together with the change of heat transfer interface increases intensity of cooling in the zone and makes less the range cooling zone and reduces the porosity of cast microstructure.

  11. Optimization Tool for Direct Water Cooling System of High Power IGBT Modules

    DEFF Research Database (Denmark)

    Bahman, Amir Sajjad; Blaabjerg, Frede

    2016-01-01

    important issue for thermal design engineers. This paper aims to present a user friendly optimization tool for direct water cooling system of a high power module which enables the cooling system designer to identify the optimized solution depending on customer load profiles and available pump power. CFD...

  12. Water vapour rises from the cooling towers for the ATLAS detector at Point 1

    CERN Multimedia

    Brice, Maximilien

    2015-01-01

    Electronics on the ATLAS detector produce heat when the experiment is running. An elaborate cooling system keeps the detector from overheating. On the surface, the warm water vapour that rises from the detector 100metres underground is clearly visible from the ATLAS cooling towers on the CERN Meyrin site in Switzerland.

  13. Foulant characteristics comparison in recycling cooling water system makeup by municipal reclaimed water and surface water in power plant.

    Science.gov (United States)

    Ping, Xu; Jing, Wang; Yajun, Zhang; Jie, Wang; Shuai, Si

    2015-01-01

    Due to water shortage, municipal reclaimed water rather than surface water was replenished into recycling cooling water system in power plants in some cities in China. In order to understand the effects of the measure on carbon steel corrosion, characteristics of two kinds of foulant produced in different systems were studied in the paper. Differences between municipal reclaimed water and surface water were analyzed firstly. Then, the weight and the morphology of two kinds of foulant were compared. Moreover, other characteristics including the total number of bacteria, sulfate reducing bacteria, iron bacteria, extracellular polymeric substance (EPS), protein (PN), and polysaccharide (PS) in foulant were analyzed. Based on results, it could be concluded that microbial and corrosive risk would be increased when the system replenished by municipal reclaimed water instead of surface water.

  14. An Innovative System for the Efficient and Effective Treatment of Non-Traditional Waters for Reuse in Thermoelectric Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    John Rodgers; James Castle

    2008-08-31

    , chemical oxygen demand (COD), and zinc. Similar to FGD waters, produced waters contained contaminants of concern that are predominantly inorganic (arsenic, cadmium, chlorides, chromium, copper, lead, mercury, nickel, sulfide, zinc, total dissolved solids), but also contained some organics (benzene, PAHs, toluene, total organic carbon, total suspended solids, and oil and grease). Constituents of concern that may cause chemical scaling, biofouling and corrosion, such as pH, hardness and ionic strength, and nutrients (P, K, and N) may also be found in all four non-traditional waters. NPDES permits were obtained for these non-traditional waters and these permit limits are summarized in tabular format within this report. These limits were used to establish treatment goals for this research along with toxicity values for Ceriodaphnia dubia, water quality criteria established by the US EPA, irrigation standards established by the United States Department of Agriculture (USDA), and reuse standards focused on minimization of damage to the power plant by treated waters. Constructed wetland treatment systems were designed for each non-traditional water source based on published literature reviews regarding remediation of the constituents of concern, biogeochemistry of the specific contaminants, and previous research. During this study, 4 non-traditional waters, which included ash basin water, cooling water, FGD water and produced water (PW) were obtained or simulated to measure constructed wetland treatment system performance. Based on data collected from FGD experiments, pilot-scale constructed wetland treatment systems can decrease aqueous concentrations of elements of concern (As, B, Hg, N, and Se). Percent removal was specific for each element, including ranges of 40.1% to 77.7% for As, 77.6% to 97.8% for Hg, 43.9% to 88.8% for N, and no measureable removal to 84.6% for Se. Other constituents of interest in final outflow samples should have aqueous characteristics sufficient for

  15. Manufacturing surface hardened components of 42CrMo4 by water-air spray cooling

    Energy Technology Data Exchange (ETDEWEB)

    Gretzki, T.; Krause, C.; Frolov, I.; Hassel, T.; Nicolaus, M.; Bach, F.W. [Inst. of Materials Science, Leibniz Univ. Hannover, Garbsen (Germany); Kaestner, M.; Abo-Namous, O.; Reithmeier, E. [Inst. of Measurement and Control Engineering, Leibniz Univ. Hannover (Germany); National Metallurgical Academy of Ukraine, Dniepropetrovsk (Ukraine)

    2009-12-15

    By employing integrated heat-treatment using forging heat, a significant shortening of the process chain is attained for manufacturing precision forged components with considerable savings in time and energy. With the aid of water-air spray cooling, surface hardening and tempering can be carried out without, at the same time, reheating the component following quenching. In this work, geometric models of splines and single cylinder crankshafts (both made of 1.7225) were surface hardened and tempered using a purpose-built rotating spray unit The obtained hardness, microstructures and their distortions were investigated. To optically and spatially detect the components, fringe and shadow projection systems were employed. In a second research topic, the influence of the spray parameters on the component's distortion was investigated. For both components; the splined shaft and the crankshaft geometries, it was possible to carry out successful surface heat-treatments using these processes. (orig.)

  16. Treatment of Sewer Water Using Alum Salt

    OpenAIRE

    Qaid M. Saleem; Yousif Mohamed Algamal; Majed H. Shtaiwi; Mohammad S. Aldahmashi

    2014-01-01

    This investigation was carried out to study the effect of addition of different concentrations of alum salt used in the treatment of sewer water of the pond and also to study the physico-chemical parameters such as pH ,electrical conductivity ,salinity and total sediments besides that the bacteriological analysis such as total viable count (TVC) or standard plate count (SPC) and total coliform count (MPN) content were analysed in the water sample collected from the pond estimation of viable...

  17. Combining physico-chemical analysis with a Daphnia magna bioassay to evaluate a recycling technology for drinking water treatment plant waste residuals.

    Science.gov (United States)

    Chen, Ting; Xu, Yongpeng; Zhu, Shijun; Cui, Fuyi

    2015-12-01

    Recycling water treatment plant (WTP) waste residuals is considered to be a feasible method to enhance the efficiency of pollutant removal. This study also evaluated the safety and water quality of a pilot-DWTP waste residuals recycling technology by combining physical-chemistry analysis with a Daphnia magna assay. The water samples taken from each treatment step were extracted and concentrated by XAD-2 resin and were then analyzed for immobilization and enzyme activity with D. magna. The measured parameters, such as the dissolve organic carbon (DOC), UV254 and THM formation potential (THMFPs) of the recycling process, did not obviously increase over 15 days of continuous operation and were even lower than typical values from a conventional process. The extract concentration ranged from 0 to 2 Leq/ml as measured on the 7th and 15th days and the immobilization of D. magna exposed to water treated by the recycling process was nearly equivalent to that of the conventional process. Both the superoxide dismutase (SOD) and the catalase (CAT) activity assay indicated that a lower dose of water extract (0.5, 1, 1.5 Leq/ml) could stimulate the enzyme activity of D. magna, whereas a higher dose (2 Leq/ml at the sampling point C3, R3, R4 ) inhibits the activity. Moreover, the SOD and CAT activity of D. magna with DOC and UV254 showed a strong concentration-effect relationship, where the concentration range of DOC and UV254 were 4.1-16.2 mg/L and 0.071-4.382 cm(-1), respectively. The results showed that there was no statistically significant difference (p>0.05) between the conventional and recycling treatment processes and the toxicity of water samples in the recycling process did not increase during the 15-day continuous recycling trial. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. The distribution of inherent phosphorus in fifteen water treatment ...

    African Journals Online (AJOL)

    2012-02-08

    Feb 8, 2012 ... of treatment chemicals which isolate unwanted constituents through flocculation and ... organic and inorganic matter removed from the water being ..... for example, require P treatment prior to or at the time of land application.

  19. Constructed Rapid Infiltration/Hybrid Constructed Wetland for Advanced Treatment of Tail Water from Chemical Wastewater Treatment Plant%人工快渗/复合人工湿地工艺处理园区污水厂尾水

    Institute of Scientific and Technical Information of China (English)

    曹明利; 崔康平; 许为义; 洪天求

    2012-01-01

    A combined process of constructed rapid infiltration, two-stage horizontal subsurface flow wetland, surface flow wetland, oxidation pond and tertiary horizontal subsurface flow wetland was designed for advanced treatment of tail water from chemical wastewater treatment plant in an industrial park. The performance of the combined process was investigated in trial operation for a year. The results showed that the whole treatment system had stable performance in treatment of tail water. The average removal rates of COD, NH3 - N and TP were 78. 8% , 86. 9% and 76. 4% respectively. The concentrations of COD, NH3 - N and TP in the effluent all reached the V criteria specified in the Environmental Quality Standards for Surface Water ( GB 3838 - 2002). The combined process had advantages such as low operation cost and convenient operation.%针对某工业园区混合化工污水厂尾水的水质特点,设计了基于水资源循环利用的人工快渗/两级水平潜流湿地/表面流湿地/氧化塘/三级水平潜流湿地组合工艺对其进行深度处理,考察了该工艺运行一年多来对COD、NH3 -N和TP的去除效果.结果表明,该工艺对混合化工污水厂尾水的处理效果较好,对COD、NH3 -N和TP的平均去除率分别为78.8%、86.9%和76.4%,出水COD、NH3-N和TP浓度达到《地表水环境质量标准》(GB 3838-2002)的V类标准,并具有运行费用低、操作方便等优点.

  20. Rational design of nanomaterials for water treatment

    Science.gov (United States)

    Li, Renyuan; Zhang, Lianbin; Wang, Peng

    2015-10-01

    The ever-increasing human demand for safe and clean water is gradually pushing conventional water treatment technologies to their limits. It is now a popular perception that the solutions to the existing and future water challenges will hinge upon further developments in nanomaterial sciences. The concept of rational design emphasizes on `design-for-purpose' and it necessitates a scientifically clear problem definition to initiate the nanomaterial design. The field of rational design of nanomaterials for water treatment has experienced a significant growth in the past decade and is poised to make its contribution in creating advanced next-generation water treatment technologies in the years to come. Within the water treatment context, this review offers a comprehensive and in-depth overview of the latest progress in rational design, synthesis and applications of nanomaterials in adsorption, chemical oxidation and reduction reactions, membrane-based separation, oil-water separation, and synergistic multifunctional all-in-one nanomaterials/nanodevices. Special attention is paid to the chemical concepts related to nanomaterial design throughout the review.

  1. Rational design of nanomaterials for water treatment

    KAUST Repository

    Li, Renyuan

    2015-08-26

    The ever-increasing human demand for safe and clean water is gradually pushing conventional water treatment technologies to their limits and it is now a popular perception that the solutions to the existing and future water challenges will highly hinge upon the further development of nanomaterial sciences. The concept of rational design emphasizes ‘design-for-purpose’ and it necessitates a scientifically clear problem definition to initiate the nanomaterial design. The field of rational design of nanomaterials for water treatment has experienced a significant growth in the past decade and is poised to make its contribution in creating advanced next-generation water treatment technologies in the years to come. Within the water treatment context, this review offers a comprehensive and in-depth overview of the latest progress of the rational design, synthesis and applications of nanomaterials in adsorption, chemical oxidation and reduction reactions, membrane-based separation, oil/water separation, and synergistic multifunctional all-in-one nanomaterials/nanodevices. Special attention is paid on chemical concepts of the nanomaterial designs throughout the review.

  2. Modelling of Water Turbidity Parameters in a Water Treatment Plant

    Directory of Open Access Journals (Sweden)

    A. S. KOVO

    2005-01-01

    Full Text Available The high cost of chemical analysis of water has necessitated various researches into finding alternative method of determining portable water quality. This paper is aimed at modelling the turbidity value as a water quality parameter. Mathematical models for turbidity removal were developed based on the relationships between water turbidity and other water criteria. Results showed that the turbidity of water is the cumulative effect of the individual parameters/factors affecting the system. A model equation for the evaluation and prediction of a clarifier’s performance was developed:Model: T = T0(-1.36729 + 0.037101∙10λpH + 0.048928t + 0.00741387∙alkThe developed model will aid the predictive assessment of water treatment plant performance. The limitations of the models are as a result of insufficient variable considered during the conceptualization.

  3. Control of modiolid mussels in cooling water systems by continuous chlorination.

    NARCIS (Netherlands)

    Rajagopal, S.; Venugopalan, V.P.; Velde, G. van der; Jenner, H.A.

    2006-01-01

    Abstract. Modiolid mussels such as Modiolus philippinarum and Modiolus metcalfei constitute a numerically significant group in fouling communities, especially in tropical and subtropical industrial cooling water systems. Nevertheless, there are hardly any published reports on the tolerance of these

  4. Control of modiolid mussels in cooling water systems by continuous chlorination.

    NARCIS (Netherlands)

    Rajagopal, S.; Venugopalan, V.P.; Velde, G. van der; Jenner, H.A.

    2006-01-01

    Abstract. Modiolid mussels such as Modiolus philippinarum and Modiolus metcalfei constitute a numerically significant group in fouling communities, especially in tropical and subtropical industrial cooling water systems. Nevertheless, there are hardly any published reports on the tolerance of these

  5. INVESTIGATION OF THE PERFORMANCE OF AN ATMOSPHERIC COOLING TOWER USING FRESH AND SALTED WATER

    OpenAIRE

    A. Haddad

    2012-01-01

    Cooling towers are extensively used to evacuate large quantities of heat at modest temperatures through a change of phase of the flowing cooling fluid. Based on this classical principle, the present study investigates the influence of salty water on the heat exchange produced. For that purpose, experiments are carried out using fresh and salty water. Furthermore, a comparison with the results produced through an approach involving the solution of energy equation involving the flow...

  6. 蓄能式中央空调冷却水系统横流湿式冷却塔环保降噪的治理方法%The Administrative Methods for the Noise treatment FSR of the many sets of Mechanical Draft crossfolw Cooling Towers in Water Storage Central Air Conditioning System

    Institute of Scientific and Technical Information of China (English)

    冯荣贞; 刘晓东; 周玉琼

    2014-01-01

    This article takes noise treatment for the many sets of mechanical draft crossflow cooling towers noise for example ,which was layed on the housetop of water storage central air conditioning system. The plans of the noise treatment were given, and the analysis was also brought forward-which including single and united plan.The best plan was selected, the plan was to build the half obturated set of sound insulation and noise elimination, on which there were sound barriers, and to set noise suppressors in cistern of cooling tower. This set was used of light quality structure. Its load was transited by the steel column transmission to the original building column, so that the reinforcement processing measure to the housetop was omitted. Noise treatment measure was few effect of resistance losing for cooling towers, and kept cooling towers thermal performance and normal operation. This paper affords theorical basis for engineering, and a new way was found in decreasing noise of cooling tower.%本文针对蓄冷中央空调系统机力横流湿式冷却塔夜间低谷电满负荷蓄冷运行,白天电力峰值时部分释冷运行的特点及冷却塔自身的噪声污染进行了分析,提出了噪声治理方案,就单个方案及多方案联合进行了综合分析,最终选定了最优实施方案,即“半封闭式声屏导风板降噪+风机消音装置+落水消能降噪器”。半封闭式隔声屏导风板采用轻质结构,屋面增加的荷载通过钢立柱传递至原有建筑物砼立柱上,省去了对原有结构的加固处理措施。并且所采取的降噪措施对冷却塔进排风的阻力损失影响控制在允许范围之内,保证了冷却塔的热工性能及正常运行。本文对工程实际中的冷却塔的降噪提供了新思路。

  7. Discussion on Disposing Acid Waste Water by Physico-chemical Treatment Technology%利用物化技术处理含酸废水的技术探讨

    Institute of Scientific and Technical Information of China (English)

    张绍坤

    2013-01-01

    Based on analyzing al kinds of the disposal technology characters and application on acid waste water, the article approves that the physico-chemical treatment technology could effectively dispose al kinds of acid waste water. The physico-chemical treatment technology had some advantages such as wide adaptability on waste water, high heavy metal removal efficiency, and so on. So it can be used widely in the waste water disposal projects. According to the application of waste water disposal projects, the article points out several shortcomings need to be solved, such as the high disposal cost, the hard process control.%  通过分析各种含酸废水处理技术的特点和工程应用,指出利用物化技术能够有效处理各种含酸废水,具有废水适应性广、重金属去除效率高等优点,适合工程应用;物化技术在实际工程应用中,还存在处理成本高、工艺控制点不易控制等不足,需进一步研究加以克服。

  8. Assessment of stress-corrosion cracking in a water-cooled ITER

    Energy Technology Data Exchange (ETDEWEB)

    Jones, R.H.; Bruemmer, S.M.

    1989-04-01

    Water-cooled, near-term reactors will operate under conditions at which SCC is possible; however, control of material purity and processing and coolant chemistry can either eliminate or greatly reduce the probability of this type of structural failure. This evaluation has focused on an assessment of water impurity effects on SCC of austenitic stainless steel at temperatures below 100{degree}C and on the conditions controlling sensitization in the fusion heat of Type 316 SS and the fusion materials heat of modified Type 316 SS designated as PCA. This assessment identifies the dominant effect of small concentrations of impurities in high-purity water on SCC such that crack growth rates at 25--75{degree}C in water with as little as 5--15 ppM Cl{sup {minus}} are equal to the crack growth rates at 200--300{degree}C in high-purity water. These effects are primarily for sensitized Type 304 SS, so analysis of sensitization behavior of fusion austenitic alloys was also undertaken. An SSDOS model developed at PNL was used to make these assessments, and correlation to experimental results for Type 316 SS was very good. Both the fusion heat of Type 316 SS and PCA can be severely sensitized but with proper thermal treatment it should be possible to avoid sensitization. 14 refs., 8 figs.

  9. Heat transfer analysis during cooling of die with use of water mist

    Directory of Open Access Journals (Sweden)

    R. Władysiak

    2011-07-01

    Full Text Available The paper presents the results of the heat transfer area during the cooling process of steel test die with water mist which consist the flow of air in the range 150÷350 l/min and 0.05 0.24 l/min of water. Temperature change in the thickness of die by means showing with the thermal curves and the temperature gradient and temperature distribution in the space between the nozzle and the cooled surface of the metal mold using a thermal imaging camera and thermocouples measurement. The course of changes in the temperature gradient and the received heat flux from the die while cooling its with the flow of air and water mist stream. It has been shown that the use of water mist with a variable flow of air and water controls the process of heat transfer process between the permanent molds, and a stream of water mist.

  10. Water cooled breeder program summary report (LWBR (Light Water Breeder Reactor) development program)

    Energy Technology Data Exchange (ETDEWEB)

    1987-10-01

    The purpose of the Department of Energy Water Cooled Breeder Program was to demonstrate pratical breeding in a uranium-233/thorium fueled core while producing electrical energy in a commercial water reactor generating station. A demonstration Light Water Breeder Reactor (LWBR) was successfully operated for more than 29,000 effective full power hours in the Shippingport Atomic Power Station. The reactor operated with an availability factor of 76% and had a gross electrical output of 2,128,943,470 kilowatt hours. Following operation, the expended core was examined and no evidence of any fuel element defects was found. Nondestructive assay of 524 fuel rods determined that 1.39 percent more fissile fuel was present at the end of core life than at the beginning, proving that breeding had occurred. This demonstrates the existence of a vast source of electrical energy using plentiful domestic thorium potentially capable of supplying the entire national need for many centuries. To build on the successful design and operation of the Shippingport Breeder Core and to provide the technology to implement this concept, several reactor designs of large breeders and prebreeders were developed for commercial-sized plants of 900--1000 Mw(e) net. This report summarizes the Water Cooled Breeder Program from its inception in 1965 to its completion in 1987. Four hundred thirty-six technical reports are referenced which document the work conducted as part of this program. This work demonstrated that the Light Water Breeder Reactor is a viable alternative as a PWR replacement in the next generation of nuclear reactors. This transition would only require a minimum of change in design and fabrication of the reactor and operation of the plant.

  11. 影响循环水处理剂阻垢分散效果的主要因素%Main Factors Affecting the Effects of Circulating Water Treatment Chemicals on Deposit Control and Dispersion

    Institute of Scientific and Technical Information of China (English)

    李本高; 余正齐

    2000-01-01

    用静态阻垢实验方法对目前常用的9类典型的水处理剂阻垢分散效果进行研究,试验结果表明药剂的投加浓度、水中的钙硬和碱度、浊度、铁离子浓度以及杀菌剂对不同类型水处理剂的阻垢分散效果的影响是不同的,因此,应根据水处理剂的类型确定使用条件。%The effects of 9 typical water treatment chemicals in common use presently on deposit control and dispersionwere studied through static deposit control tests. The results of the tests show that the concentration of the fed treatment agent,the calcium hardness, alkalinity, turbidity and iron ion concentration of water as well as biocides have different effects on thedeposit control and dispersion results of different types of water treatment agents and, therefore, the conditions for the use ofwater treatment agents should be determined depending upon the types of the water treatment agents.

  12. WATER MICROPOLLUTANTS: CLASSIFICATION AND TREATMENT TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    Yolanda Patiño

    2014-06-01

    Full Text Available This article reviews the different kinds of emerging contaminants, their origin and use, and their presence in the Spanish waters, both in surface and groundwater. Micropollutants are compounds of different origin and chemical nature which had been unnoticed (due to their low concentration and don’t have specific regulation. They are divided into six major groups, and many of them behave as endocrine disruptors causing large negative effects on human health and environment. They are in waters because the waste water treatment plants are not designed for their removal, so they are being discharged. Different alternatives for their removal are discussed - physico- chemical, biological and hybrid treatment technologies -. Among the physicochemical process, the advance oxidation processes (AOPs are very promising.

  13. Implications of Transitioning from De Facto to Engineered Water Reuse for Power Plant Cooling.

    Science.gov (United States)

    Barker, Zachary A; Stillwell, Ashlynn S

    2016-05-17

    Thermoelectric power plants demand large quantities of cooling water, and can use alternative sources like treated wastewater (reclaimed water); however, such alternatives generate many uncertainties. De facto water reuse, or the incidental presence of wastewater effluent in a water source, is common at power plants, representing baseline conditions. In many cases, power plants would retrofit open-loop systems to cooling towers to use reclaimed water. To evaluate the feasibility of reclaimed water use, we compared hydrologic and economic conditions at power plants under three scenarios: quantified de facto reuse, de facto reuse with cooling tower retrofits, and modeled engineered reuse conditions. We created a genetic algorithm to estimate costs and model optimal conditions. To assess power plant performance, we evaluated reliability metrics for thermal variances and generation capacity loss as a function of water temperature. Applying our analysis to the greater Chicago area, we observed high de facto reuse for some power plants and substantial costs for retrofitting to use reclaimed water. Conversely, the gains in reliability and performance through engineered reuse with cooling towers outweighed the energy investment in reclaimed water pumping. Our analysis yields quantitative results of reclaimed water feasibility and can inform sustainable management of water and energy.

  14. Energy penalty analysis of possible cooling water intake structurerequirements on existing coal-fired power plants.

    Energy Technology Data Exchange (ETDEWEB)

    Veil, J. A.; Littleton, D. J.; Gross, R. W.; Smith, D. N.; Parsons, E.L., Jr.; Shelton, W. W.; Feeley, T. J.; McGurl, G. V.

    2006-11-27

    Section 316(b) of the Clean Water Act requires that cooling water intake structures must reflect the best technology available for minimizing adverse environmental impact. Many existing power plants in the United States utilize once-through cooling systems to condense steam. Once-through systems withdraw large volumes (often hundreds of millions of gallons per day) of water from surface water bodies. As the water is withdrawn, fish and other aquatic organisms can be trapped against the screens or other parts of the intake structure (impingement) or if small enough, can pass through the intake structure and be transported through the cooling system to the condenser (entrainment). Both of these processes can injure or kill the organisms. EPA adopted 316(b) regulations for new facilities (Phase I) on December 18, 2001. Under the final rule, most new facilities could be expected to install recirculating cooling systems, primarily wet cooling towers. The EPA Administrator signed proposed 316(b) regulations for existing facilities (Phase II) on February 28, 2002. The lead option in this proposal would allow most existing facilities to achieve compliance without requiring them to convert once-through cooling systems to recirculating systems. However, one of the alternate options being proposed would require recirculating cooling in selected plants. EPA is considering various options to determine best technology available. Among the options under consideration are wet-cooling towers and dry-cooling towers. Both types of towers are considered to be part of recirculating cooling systems, in which the cooling water is continuously recycled from the condenser, where it absorbs heat by cooling and condensing steam, to the tower, where it rejects heat to the atmosphere before returning to the condenser. Some water is lost to evaporation (wet tower only) and other water is removed from the recirculating system as a blow down stream to control the building up of suspended and

  15. Thermal and electrical energy yield analysis of a directly water cooled photovoltaic module

    Directory of Open Access Journals (Sweden)

    Mtunzi Busiso

    2016-01-01

    Full Text Available Electrical energy of photovoltaic modules drops by 0.5% for each degree increase in temperature. Direct water cooling of photovoltaic modules was found to give improved electrical and thermal yield. A prototype was put in place to analyse the field data for a period of a year. The results showed an initial high performance ratio and electrical power output. The monthly energy saving efficiency of the directly water cooled module was found to be approximately 61%. The solar utilisation of the naturally cooled photovoltaic module was found to be 8.79% and for the directly water cooled module its solar utilisation was 47.93%. Implementation of such systems on households may reduce the load from the utility company, bring about huge savings on electricity bills and help in reducing carbon emissions.

  16. Preparation of semi-solid aluminum alloy slurry poured through a water-cooled serpentine channel

    Science.gov (United States)

    Chen, Zheng-Zhou; Mao, Wei-Min; Wu, Zong-Chuang

    2012-01-01

    A water-cooled serpentine channel pouring process was invented to produce semi-solid A356 aluminum alloy slurry for rheocasting, and the effects of pouring temperature and circulating cooling water flux on the microstructure of the slurry were investigated. The results show that at the pouring temperature of 640-680°C and the circulating cooling water flux of 0.9 m3/h, the semi-solid A356 aluminum alloy slurry with spherical primary α(Al) grains can be obtained, whose shape factors are between 0.78 and 0.86 and the grain diameter can reach 48-68 μm. When the pouring temperatures are at 660-680°C, only a very thin solidified shell remains inside the serpentine channel and can be removed easily. When the serpentine channel is cooled with circulating water, the microstructure of the semi-solid slurry can be improved, and the serpentine channel is quickly cooled to room temperature after the completion of one pouring. In terms of the productivity of the special equipment, the water-cooled serpentine channel is economical and efficient.

  17. 78 FR 63516 - Initial Test Program of Emergency Core Cooling Systems for New Boiling-Water Reactors

    Science.gov (United States)

    2013-10-24

    ... COMMISSION Initial Test Program of Emergency Core Cooling Systems for New Boiling-Water Reactors AGENCY... Cooling Systems for New Boiling-Water Reactors.'' This RG describes testing methods the NRC staff considers acceptable for demonstrating the operability of emergency core cooling systems (ECCSs) for boiling...

  18. Summary of research and development effort on air and water cooling of gas turbine blades

    Energy Technology Data Exchange (ETDEWEB)

    Fraas, A.P.

    1980-03-01

    The review on air- and water-cooled gas turbines from the 1904 Lemale-Armengaud water-cooled gas turbine, the 1948 to 1952 NACA work, and the program at GE indicates that the potential of air cooling has been largely exploited in reaching temperatures of 1100/sup 0/C (approx. 2000/sup 0/F) in utility service and that further increases in turbine inlet temperature may be obtained with water cooling. The local heat flux in the first-stage turbine rotor with water cooling is very high, yielding high-temperature gradients and severe thermal stresses. Analyses and tests indicate that by employing a blade with an outer cladding of an approx. 1-mm-thick oxidation-resistant high-nickel alloy, a sublayer of a high-thermal-conductivity, high-strength, copper alloy containing closely spaced cooling passages approx. 2 mm in ID to minimize thermal gradients, and a central high-strength alloy structural spar, it appears possible to operate a water-cooled gas turbine with an inlet gas temperature of 1370/sup 0/C. The cooling-water passages must be lined with an iron-chrome-nickel alloy must be bent 90/sup 0/ to extend in a neatly spaced array through the platform at the base of the blade. The complex geometry of the blade design presents truly formidable fabrication problems. The water flow rate to each of many thousands of coolant passages must be metered and held to within rather close limits because the heat flux is so high that a local flow interruption of only a few seconds would lead to a serious failure.Heat losses to the cooling water will run approx. 10% of the heat from the fuel. By recoverying this waste heat for feedwater heating in a command cycle, these heat losses will give a degradation in the power plant output of approx. 5% relative to what might be obtained if no cooling were required. However, the associated power loss is less than half that to be expected with an elegant air cooling system.

  19. Improving of the photovoltaic / thermal system performance using water cooling technique

    Science.gov (United States)

    Hussien, Hashim A.; Numan, Ali H.; Abdulmunem, Abdulmunem R.

    2015-04-01

    This work is devoted to improving the electrical efficiency by reducing the rate of thermal energy of a photovoltaic/thermal system (PV/T).This is achieved by design cooling technique which consists of a heat exchanger and water circulating pipes placed at PV module rear surface to solve the problem of the high heat stored inside the PV cells during the operation. An experimental rig is designed to investigate and evaluate PV module performance with the proposed cooling technique. This cooling technique is the first work in Iraq to dissipate the heat from PV module. The experimental results indicated that due to the heat loss by convection between water and the PV panel's upper surface, an increase of output power is achieved. It was found that without active cooling, the temperature of the PV module was high and solar cells could only achieve a conversion efficiency of about 8%. However, when the PV module was operated under active water cooling condition, the temperature was dropped from 76.8°C without cooling to 70.1°C with active cooling. This temperature dropping led to increase in the electrical efficiency of solar panel to 9.8% at optimum mass flow rate (0.2L/s) and thermal efficiency to (12.3%).

  20. Water-lithium bromide double-effect absorption cooling analysis. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Vliet, G.C.; Lawson, M.B.; Lithgow, R.A.

    1980-12-01

    This investigation involved the development of a numerical model for the transient simulation of the double-effect, water-lithium bromide absorption cooling machine, and the use of the model to determine the effect of the various design and input variables on the absorption unit performance. The performance parameters considered were coefficient of performance and cooling capacity. The sensitivity analysis was performed by selecting a nominal condition and determining performance sensitivity for each variable with others held constant. The variables considered in the study include source hot water, cooling water, and chilled water temperatures; source hot water, cooling water, and chilled water flow rates; solution circulation rate; heat exchanger areas; pressure drop between evaporator and absorber; solution pump characteristics; and refrigerant flow control methods. The performance sensitivity study indicated in particular that the distribution of heat exchanger area among the various (seven) heat exchange components is a very important design consideration. Moreover, it indicated that the method of flow control of the first effect refrigerant vapor through the second effect is a critical design feature when absorption units operate over a significant range of cooling capacity. The model was used to predict the performance of the Trane absorption unit with fairly good accuracy. The dynamic model should be valuable as a design tool for developing new absorption machines or modifying current machines to make them optimal based on current and future energy costs.

  1. Operational Experience of Cooling Water Systems for Accelerator Components at PLS

    CERN Document Server

    Kim, Kyungryul; Kim, Young-Chan; Lee, Bongho; Sik Han, Hong; Soo Ko In; Wha Chung, Chin

    2005-01-01

    The cooling water system has been utilized for absorbing heat generated by a multitude of electromagnetic power delivering networks at PLS. The separate cooling water distribution systems for the storage ring, beam transport line and linear accelerator have been operated with a different operating temperature of supplying water. All water used for heat removal from the accelerator components are deionised and filtered to provide with over 2 MO-cm specific resistance. The operating pressures and flows of input water are also controlled with flow balancing scheme at a specified range. The operating temperature of components in the accelerator is sustained as tight as below ±0.1 deg C to minimize the influence of temperature fluctuation on the beam energy and stability. Although the PLS cooling systems were initially installed with a high degree of flexibility to allow for easy maintenance, a number of system improvements have been employed to enhance operational reliability and to incorporate the newly...

  2. Feasibility Study on Application of Electroadsorption Technique in Circulating Cooling Water Treatment in Thermal Power Plant%电吸附技术在火电厂循环冷却水处理中的应用可行性研究

    Institute of Scientific and Technical Information of China (English)

    沈叔云; 冯向东; 施国忠

    2015-01-01

    The waste water of circulating water system is hard to reuse because of its high salinity and large quantity. This paper conducts feasibility study on the application of electroadsorption technique in circulating cooling water treatment in power plants. The test result shows that this technique is stable in desalination and can reduce salinity and chloride ion in water by 65% or more; besides, the technique can better remove COD. The technique is characterized by its high desalination rate, meaning treatment of 1 ton of water costs 0.5Yuan. The test equipment operates in stability and its treatment efficiency is favorable, constant and ad-justable;it is tolerant and can be used for preliminary desalination of circulating water in power plant.%火电厂循环水排污水含盐量高、水量大、回用比较困难,对电吸附技术在发电厂循环水排污水回用方面进行可行性研究。试验结果表明电吸附技术有稳定的除盐效果,可有效降低和去除水中65%以上的硬度与氯离子,同时对COD亦有较好的去除效果,除盐效率高,合计1 t水处理成本约0.5元。试验设备运行稳定,处理效果好且连续可调,设备耐受性好,可以用于循环水初级脱盐处理。

  3. Cooling of Gas Turbines. 6; Computed Temperature Distribution Through Cross Section of Water-Cooled Turbine Blade

    Science.gov (United States)

    Livingood, John N. B.; Sams, Eldon W.

    1947-01-01

    A theoretical analysis of the cross-sectional temperature distribution of a water-cooled turbine blade was made using the relaxation method to solve the differential equation derived from the analysis. The analysis was applied to specific turbine blade and the studies icluded investigations of the accuracy of simple methods to determine the temperature distribution along the mean line of the rear part of the blade, of the possible effect of varying the perimetric distribution of the hot gas-to -metal heat transfer coefficient, and of the effect of changing the thermal conductivity of the blade metal for a constant cross sectional area blade with two quarter inch diameter coolant passages.

  4. Startup of Pumping Units in Process Water Supplies with Cooling Towers at Thermal and Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Berlin, V. V., E-mail: vberlin@rinet.ru; Murav’ev, O. A., E-mail: muraviov1954@mail.ru; Golubev, A. V., E-mail: electronik@inbox.ru [National Research University “Moscow State University of Civil Engineering,” (Russian Federation)

    2017-03-15

    Aspects of the startup of pumping units in the cooling and process water supply systems for thermal and nuclear power plants with cooling towers, the startup stages, and the limits imposed on the extreme parameters during transients are discussed.

  5. Effects of sonication and advanced chemical oxidants on the unicellular green alga Dunaliella tertiolecta and cysts, larvae and adults of the brine shrimp Artemia salina: a prospective treatment to eradicate invasive organisms from ballast water.

    Science.gov (United States)

    Gavand, Meghana R; McClintock, James B; Amsler, Charles D; Peters, Robert W; Angus, Robert A

    2007-11-01

    Uptake and release of ship-borne ballast water is a major factor contributing to introductions of aquatic phytoplankton and invasive macroinvertebrates. Some invasive unicellular algae can cause harmful algal blooms and produce toxins that build up in food chains. Moreover, to date, few studies have compared the efficacy of ballast water treatments against different life history phases of aquatic macroinvertebrates. In the present study, the unicellular green alga Dunaliella tertiolecta, and three discrete life history phases of the brine shrimp Artemia salina, were independently used as model organisms to study the efficacy of sonication as well as the advanced oxidants, hydrogen peroxide and ozone, as potential ballast water treatments. Algal cells and brine shrimp cysts, nauplii, and adults were subjected to individual and combined treatments of sonication and advanced oxidants. Combined rather than individual treatments consistently yielded the highest levels of mortality in algal cells (100% over a 2 min exposure) and in brine shrimp (100% and 95% for larvae and adults, respectively, over a 2 min exposure). In contrast, mortality levels in brine shrimp cysts (66% over 2 min; increased to 92% over a 20 min exposure) were moderately high but consistently lower than that detected for larval or adult shrimp. Our results indicate that a combination of sonication and advanced chemical oxidants may be a promising method to eradicate aquatic unicellular algae and macroinvertebrates in ballast water.

  6. Cooling tower for the cooling water that drains from the condensor of a steam generator or the condensors of a plurality of steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Jorzyk, S.; Scholl, G.; Hoelter, H.; Igelbuescher, H.; Gresch, H.; Dewert, H.

    1989-09-05

    This invention relates to a cooling tower for the cooling water that drains from the condenser of a steam generator or from the condensers of a plurality of steam generators. The tower is fitted with large-area inserts and these form a heat-exchange area into which the cooling water is passed. A rising flow of air passes through this zone in counterflow to the cooling water. The cooling tower is provided with a smoke-gas feed to introduce cleaned, preferably wet-cleaned, smoke gas into the flow of cooling air, which is connected to a plurality of gas outlet pipes. The outlet cross-sections of those pipes open out into the cooling tower above the heat-exchange zone. In order to improve the introduction of the cleaned smoke gases into the flow of cooling air within a cooling tower, this invention proposes that rotors be provided in the gas outlet pipes in the area of their outlet cross-sections. To this end, it is also possible to make each gas outlet pipe rotatable about its longitudinal axis, the angle of inclination of the gas outlet pipes being variable.

  7. Contaminated water treatment

    Science.gov (United States)

    Gormly, Sherwin J. (Inventor); Flynn, Michael T. (Inventor)

    2010-01-01

    Method and system for processing of a liquid ("contaminant liquid") containing water and containing urine and/or other contaminants in a two step process. Urine, or a contaminated liquid similar to and/or containing urine and thus having a relatively high salt and urea content is passed through an activated carbon filter to provide a resulting liquid, to remove most of the organic molecules. The resulting liquid is passed through a semipermeable membrane from a membrane first side to a membrane second side, where a fortified drink having a lower water concentration (higher osmotic potential) than the resulting liquid is positioned. Osmotic pressure differential causes the water, but not most of the remaining inorganic (salts) contaminant(s) to pass through the membrane to the fortified drink. Optionally, the resulting liquid is allowed to precipitate additional organic molecules before passage through the membrane.

  8. Calculation of Radioactivity and Dose Rate of Activated Corrosion Products in Water-Cooled Fusion Reactor

    Directory of Open Access Journals (Sweden)

    Jingyu Zhang

    2016-01-01

    Full Text Available In water-cooled reactor, the dominant radioactive source term under normal operation is activated corrosion products (ACPs, which have an important impact on reactor inspection and maintenance. A three-node transport model of ACPs was introduced into the new version of ACPs source term code CATE in this paper, which makes CATE capable of theoretically simulating the variation and the distribution of ACPs in a water-cooled reactor and suitable for more operating conditions. For code testing, MIT PWR coolant chemistry loop was simulated, and the calculation results from CATE are close to the experimental results from MIT, which means CATE is available and credible on ACPs analysis of water-cooled reactor. Then ACPs in the blanket cooling loop of water-cooled fusion reactor ITER under construction were analyzed using CATE and the results showed that the major contributors are the short-life nuclides, especially Mn-56. At last a point kernel integration code ARShield was coupled with CATE, and the dose rate around ITER blanket cooling loop was calculated. Results showed that after shutting down the reactor only for 8 days, the dose rate decreased nearly one order of magnitude, which was caused by the rapid decay of the short-life ACPs.

  9. Biofouling reduction in recirculating cooling systems through biofiltration of process water.

    Science.gov (United States)

    Meesters, K P H; Van Groenestijn, J W; Gerritse, J

    2003-02-01

    Biofouling is a serious problem in industrial recirculating cooling systems. It damages equipment, through biocorrosion, and causes clogging and increased energy consumption, through decreased heat transfer. In this research a fixed-bed biofilter was developed which removed assimilable organic carbon (AOC) from process water, thus limiting the major substrate for the growth of biofouling. The biofilter was tested in a laboratory model recirculating cooling water system, including a heat exchanger and a cooling tower. A second identical model system without a biofilter served as a reference. Both installations were challenged with organic carbon (sucrose and yeast extract) to provoke biofouling. The biofilter improved the quality of the recirculating cooling water by reducing the AOC content, the ATP concentration, bacterial numbers (30-40 fold) and the turbidity (OD660). The process of biofouling in the heat exchangers, the process water pipelines and the cooling towers, was monitored by protein increase, heat transfer resistance, and chlorine demanded for maintenance. This revealed that biofouling was lower in the system with the biofilter compared to the reference installation. It was concluded that AOC removal through biofiltration provides an attractive, environmental-friendly means to reduce biofouling in industrial cooling systems.

  10. Smart energy option: Reusing wastewater for cooling energy

    Energy Technology Data Exchange (ETDEWEB)

    Clapham, A. [Boeing Co., Seattle, WA (United States); Jackman, J. [Puget Sound Power and Light Co., Bellevue, WA (United States); Lundt, M.M. [King County Department of Metropolitan Services, Seattle, WA (United States). Water Pollution Control Dept.

    1996-12-31

    The King County Department of Metropolitan Services, an airplane manufacturer, and a Seattle utility are ready to begin operating the first commercial effluent-based cooling system for buildings in the Northwest. This paper details the studies undertaken to design the system and how the manufacturer addressed its employees` concerns about a new system. There are several environmental benefits to using effluent as a cooling medium. Considerable energy savings in chiller operations are achieved because the effluent temperature is 10 to 20 degrees cooler than water returned from cooling towers. Another major benefit is water conservation. Conventional cooling towers would consume several million gallons of water each year. By using effluent, the consumption of this water will be avoided. Water run through cooling towers is treated with chemicals to prevent corrosion and biological growth. With the effluent in a closed-loop system, there will be no need to treat the effluent. Consequently there will be a reduction in use of water treatment chemicals that are ultimately discharged into the sewer system. This reduces the treatment load to the county and helps to maintain a cleaner environment. The concept is simple: recover heat wasted from one activity for reuse in another. The delivery is easy: send effluent via a pipeline to customer`s chillers to pick up heat and return that heat to the plant. The selling of this idea is the focus of this paper.

  11. The cool state of water: Infrared insights into ice

    NARCIS (Netherlands)

    Smit, W.J.

    2016-01-01

    Water is an extraordinary substance. It owes its characteristic anomalous properties to a network of strong hydrogen bonds present between water molecules. In ice, water molecules hold regular positions in the crystal. Nevertheless, the behaviour of ice can be dynamic and exciting, especially at the

  12. Technology to Facilitate the Use of Impaired Waters in Cooling Towers

    Energy Technology Data Exchange (ETDEWEB)

    Colborn, Robert

    2012-04-30

    The project goal was to develop an effective silica removal technology and couple that with existing electro-dialysis reversal (EDR) technology to achieve a cost effective treatment for impaired waters to allow for their use in the cooling towers of coal fired power plants. A quantitative target of the program was a 50% reduction in the fresh water withdrawal at a levelized cost of water of $3.90/Kgal. Over the course of the program, a new molybdenum-modified alumina was developed that significantly outperforms existing alumina materials in silica removal both kinetically and thermodynamically. The Langmuir capacity is 0.11g silica/g adsorbent. Moreover, a low cost recycle/regeneration process was discovered to allow for multiple recycles with minimal loss in activity. On the lab scale, five runs were carried out with no drop in performance between the second and fifth run in ability to absorb the silica from water. The Mo-modified alumina was successfully prepared on a multiple kilogram scale and a bench scale model column was used to remove 100 ppm of silica from 400 liters of simulated impaired water. Significant water savings would result from such a process and the regeneration process could be further optimized to reduce water requirements. Current barriers to implementation are the base cost of the adsorbent material and the fine powder form that would lead to back pressure on a large column. If mesoporous materials become more commonly used in other areas and the price drops from volume and process improvements, then our material would also lower in price because the amount of molybdenum needed is low and no additional processing is required. There may well be engineering solutions to the fine powder issue; in a simple concept experiment, we were able to pelletize our material with Boehmite, but lost performance due to a dramatic decrease in surface area.

  13. Optimum Design and Operation of an HVAC Cooling Tower for Energy and Water Conservation

    Directory of Open Access Journals (Sweden)

    Clemente García Cutillas

    2017-03-01

    Full Text Available The energy consumption increase in the last few years has contributed to developing energy efficiency policies in many countries, the main goal of which is decreasing CO 2 emissions. One of the reasons for this increment has been caused by the use of air conditioning systems due to new comfort standards. In that regard, cooling towers and evaporative condensers are presented as efficient devices that operate with low-level water temperature. Moreover, the energy consumption and the cost of the equipment are lower than other systems like air condensers at the same operation conditions. This work models an air conditioning system in TRNSYS software, the main elements if which are a cooling tower, a water-water chiller and a reference building. The cooling tower model is validated using experimental data in a pilot plant. The main objective is to implement an optimizing control strategy in order to reduce both energy and water consumption. Furthermore a comparison between three typical methods of capacity control is carried out. Additionally, different cooling tower configurations are assessed, involving six drift eliminators and two water distribution systems. Results show the influence of optimizing the control strategy and cooling tower configuration, with a maximum energy savings of 10.8% per story and a reduction of 4.8% in water consumption.

  14. Simultaneous effects of water spray and crosswind on performance of natural draft dry cooling tower

    Directory of Open Access Journals (Sweden)

    Ahmadikia Hossein

    2013-01-01

    Full Text Available To investigate the effect of water spray and crosswind on the effectiveness of the natural draft dry cooling tower (NDDCT, a three-dimensional model has been developed. Efficiency of NDDCT is improved by water spray system at the cooling tower entrance for high ambient temperature condition with and without crosswind. The natural and forced heat convection flow inside and around the NDDCT is simulated numerically by solving the full Navier-Stokes equations in both air and water droplet phases. Comparison of the numerical results with one-dimensional analytical model and the experimental data illustrates a well-predicted heat transfer rate in the cooling tower. Applying water spray system on the cooling tower radiators enhances the cooling tower efficiency at both no wind and windy conditions. For all values of water spraying rate, NDDCTs operate most effectively at the crosswind velocity of 3m/s and as the wind speed continues to rise to more than 3 m/s up to 12 m/s, the tower efficiency will decrease by approximately 18%, based on no-wind condition. The heat transfer rate of radiator at wind velocity 10 m/s is 11.5% lower than that of the no wind condition. This value is 7.5% for water spray rate of 50kg/s.

  15. Reuse & Recirculation of Filter Backwash Water of Water Treatment Water

    Directory of Open Access Journals (Sweden)

    Mangesh L. Jibhakate

    2017-04-01

    Full Text Available Most of the water treatment plant, filtration is done by means of sand filtration process. Due to continuous filtration process, sand pores get clogged and decreases the efficiency. For mitigating such problem, reverse flow of water & air i.e. backwashing process is carried out. To carry out backwashing operation, 4% of treated water has been utilized and will result in muddy water known as backwash water. This backwash water is then discharged into a natural stream or storage tank near the plant for recirculation. The present study includes a trial for the reuse & recirculation of backwash water.

  16. SELECTION OF CHEMICAL TREATMENT PROGRAM FOR OILY WASTEWATER

    Directory of Open Access Journals (Sweden)

    Miguel Díaz

    2017-04-01

    Full Text Available When selecting a chemical treatment program for wastewater to achieve an effective flocculation and coagulation is crucial to understand how individual colloids interact. The coagulation process requires a rapid mixing while flocculation process needs a slow mixing. The behavior of colloids in water is strongly influenced by the electrokinetic charge, where each colloidal particle carries its own charge, which in its nature is usually negative. Polymers, which are long chains of high molecular weight and high charge, when added to water begin to form longer chains, allowing removing numerous particles of suspended matter. A study of physico-chemical treatment by addition of coagulant and flocculant was carried out in order to determine a chemical program for oily wastewater coming from the gravity separation process in a crude oil refinery. The tests were carried out in a Jar Test equipment, where commercial products: aluminum polychloride (PAC, aluminum sulfate and Sintec D50 were evaluated with five different flocculants. The selected chemical program was evaluated with fluids at three temperatures to know its sensitivity to this parameter and the mixing energy in the coagulation and flocculation. The chemical program and operational characteristics for physico-chemical treatment with PAC were determined, obtaining a removal of more than 93% for suspended matter and 96% for total hydrocarbons for the selected coagulant / flocculant combination.

  17. Biotic and physico-chemical conditions in a cooling reservoir of a coal-fired power plant

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Cholla Lake is a cooling reservoir for the coal fired Cholla electrical generating plant. The lake provides recreational fishing and water contact recreation. The...

  18. Technology Evaluation for Treatment/Disposal of TNT Red Water

    Science.gov (United States)

    1990-04-01

    TABLE 2-2. DATA BASES INVESTIGATED BY USATHAMA AND PE! IN LITERATURE SEARCH FOR INFORMATION ON TNT RED WATER AND ITS TREATMENTe Agricola (1979-1988...Environmental Bibliography Chemical Business Newsbase Federal Index Chemical Engineering Abstract Federal Register Abstract Chemical Exposure GPO Monthly

  19. The Modification of Sodium Polyacrylate Water Solution Cooling Properties by AL2O3

    Directory of Open Access Journals (Sweden)

    Wojciech Gęstwa

    2010-01-01

    Based on cooling curves, it can be concluded that for the water solution of sodium polyacrylate with AL2O3 nanoparticles in comparison to water and 10% polymer water solution lower cooling speed is obtained. The cooling medium containing nanoparticles provides lower cooling speed in the smallest surface austenite occurance (500–600 C in the charts of the CTP for most nonalloy structural steels and low-alloy steels. However lower cooling temperature at the beginning of martensitic transformation causes the formation of smaller internal stresses, leading to smaller dimensional changes and hardening deformation. For the quenching media the wetting angle was appointed by the drop-shape method. These studies showed the best wettability of polymer water solution (sodium polyacrylate with the addition of AL2O3 nanoparticles, whose wetting angle was about 65 degrees. Obtaining the smallest wetting angle for the medium containing nanoparticles suggests that the heat transfer to the cooling medium is larger. This allows slower cooling at the same time ensuring its homogeneity. The obtained values of wetting angle confirm the conclusions drawn on the basis of cooling curves and allowus to conclude that in the case of the heat transfer rate it will have a lower value than for water and 10% polymer water solution. In the research on hardened carburized steel samples C10 and 16MnCr5 surface hardness, impact strength and changes in the size of cracks in Navy C-ring sample are examined. On this basis of the obtained results it can be concluded that polymer water solution with nanoparticles allows to obtain a better impact strength at comparable hardness on the surface. Research on the dimensional changes on the basis of the sample of Navy C-ring also shows small dimensional changes for samples carburized and hardened in 10% polymer water solution with the addition of nanoparticles AL2O3. Smaller dimensional changes were obtained for samples of steel 16MnCr5 thanfar C10. The

  20. Soft-Sensing Method of Water Temperature Measurement for Controlled Cooling System

    Institute of Scientific and Technical Information of China (English)

    CAI Xiao-hui; ZHANG Dian-hua; WANG Guo-dong; LIU Xiang-hua; FAN Lei

    2003-01-01

    Aiming at the water temperature measuring problem for controlled cooling system of rolling plant, a new water temperature measuring method based on soft-sensing method with a water temperature model of on-line self correction parameter was built. A water temperature compensation factor model was also built to improve coiling temperature control precision. It was proved that the model meets production requirements. The soft-sensing technique has extensive applications in the field of metal forming.

  1. Releases from the cooling water system in the Waste Tank Farm

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, W.C.; Lux, C.R.

    1991-01-01

    On September 12, 1991, a cooling-water header broke in the H-Area Waste Tank farm, at the Savannah River Site, releasing contaminated water down a storm sewer that drains to the creek. A copy of the Occurrence Report is attached. As part of the follow-up on this incident, the NPSR Section was asked by Waste Management Technology to perform a probabilistic analysis of the following cases: (1) A large break in the header combined with a large break in a cooling coil inside a waste tank. (2) A large break in the header combined with a leak in a cooling coil inside a waste tank. (3) A large break in the header combined with a very small leak in a cooling coil inside a waste tank. This report documents the results of the analysis of these cases.

  2. Releases from the cooling water system in the Waste Tank Farm

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, W.C.; Lux, C.R.

    1991-12-31

    On September 12, 1991, a cooling-water header broke in the H-Area Waste Tank farm, at the Savannah River Site, releasing contaminated water down a storm sewer that drains to the creek. A copy of the Occurrence Report is attached. As part of the follow-up on this incident, the NPSR Section was asked by Waste Management Technology to perform a probabilistic analysis of the following cases: (1) A large break in the header combined with a large break in a cooling coil inside a waste tank. (2) A large break in the header combined with a leak in a cooling coil inside a waste tank. (3) A large break in the header combined with a very small leak in a cooling coil inside a waste tank. This report documents the results of the analysis of these cases.

  3. INVESTIGATION OF THE PERFORMANCE OF AN ATMOSPHERIC COOLING TOWER USING FRESH AND SALTED WATER

    Directory of Open Access Journals (Sweden)

    A Haddad

    2012-01-01

    Full Text Available Cooling towers are extensively used to evacuate large quantities of heat at modest temperatures through a change of phase of the flowing cooling fluid. Based on this classical principle, the present study investigates the influence of salty water on the heat exchange produced. For that purpose, experiments are carried out using fresh and salty water. Furthermore, a comparison with the results produced through an approach involving the solution of energy equation involving the flow of air on an evaporating film of fluid. The detailed results show a preponderance of fresh water over the salty.

  4. Chemical cold packs may provide insufficient enthalpy change for treatment of hyperthermia.

    Science.gov (United States)

    Phan, Samson; Lissoway, John; Lipman, Grant S

    2013-03-01

    Heat illness is a common ailment that, if left untreated, is associated with high morbidity and mortality. Chemical cold packs (CCPs) and ice packs are widely used in the pre-hospital setting and by those with limited resources, yet no controlled studies have compared the cooling of ice to that of CCPs. This study determined the theoretical cooling of CCPs on a benchtop model, comparing the results to similarly sized ice packs, and is the first known comparison of these hyperthermia treatments. The CCPs used in Stanford University's Emergency Department were activated in an insulated volume of water (2 L), and temperature was recorded at 1-second intervals in a controlled environment (41°C at 20% humidity). The procedure was repeated with 1-quart ice packs. The CCPs resulted in a 5.25°C degree temperature drop, with a time constant (time to 63% of initial temperature--a common engineering characterization metric) of 1.72 minutes for the test volume. Ice packs resulted on average in a 19.8°C temperature change, with a time constant of 26.8 minutes. The CCPs provide less overall temperature change and were shorter lived. Application of 6 CCPs on a 50th percentile male (weight 86.6 kg, height 1.7 m), assuming ideal heat transfer, would result in less than 0.5°C temperature change. Similarly configured ice packs would result in a 2.5°C change. Experiments demonstrate that CCPs are inferior to similarly sized ice packs for thermal regulation, and lose their effectiveness more quickly. These findings support the consideration of ice packs as an alternative to chemical cold packs when cooling hyperthermic patients. Copyright © 2013 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  5. Study on Effects of Diesel Engine Cooling System Parameters on Water Temperature

    Institute of Scientific and Technical Information of China (English)

    骆清国; 冯建涛; 刘国夫; 桂勇

    2011-01-01

    A simulation model for a certain diesel engine cooling system is set up by using GT-COOL. The backwater tem- perature response in different operating conditions is simulated numerically. The effects of single or multiple system parameters on the water temperature are analyzed. The results show that, changing different single parameters, the time taken for the steady backwater temperature is different, but relatively short; and if multiple parameters are changed, the time will be longer. Referred to the thermal balance test, the simulation results are validated and provide a basis for the intelligent con- trol of the cooling system.

  6. Multi-model assessment of global hydropower and cooling water discharge potential under climate change

    NARCIS (Netherlands)

    van Vliet, M. T H; van Beek, L. P H; Eisner, S.; Flörke, M.; Wada, Y.; Bierkens, M. F P

    2016-01-01

    Worldwide, 98% of total electricity is currently produced by thermoelectric power and hydropower. Climate change is expected to directly impact electricity supply, in terms of both water availability for hydropower generation and cooling water usage for thermoelectric power. Improved understanding o

  7. Multi-model assessment of global hydropower and cooling water discharge potential under climate change

    NARCIS (Netherlands)

    Vliet, van M.T.H.; Beek, van L.P.H.; Eisner, S.; Flörke, M.; Wada, Y.; Bierkens, M.F.P.

    2016-01-01

    Worldwide, 98% of total electricity is currently produced by thermoelectric power and hydropower. Climate change is expected to directly impact electricity supply, in terms of both water availability for hydropower generation and cooling water usage for thermoelectric power. Improved

  8. Multi-model assessment of global hydropower and cooling water discharge potential under climate change

    NARCIS (Netherlands)

    Vliet, van M.T.H.; Beek, van L.P.H.; Eisner, S.; Flörke, M.; Wada, Y.; Bierkens, M.F.P.

    2016-01-01

    Worldwide, 98% of total electricity is currently produced by thermoelectric power and hydropower. Climate change is expected to directly impact electricity supply, in terms of both water availability for hydropower generation and cooling water usage for thermoelectric power. Improved understandin

  9. Industrial Water Treatment Primer

    Science.gov (United States)

    1992-03-01

    2040) Gallic Acid Powder (item 2063) METHOD: It is necessary to follow the instructions furnished with the conductivity meter that is being used . The...reduces CO. Caustic soda raises pH to desired level. (Courtesy of Power: McGraw-Hill Publications) (2) A hydrogen zeolite softener (Figure 9) uses acid ...a) The acid used in the regeneration process makes the effluent water more corrosive (lower pH on effluent). (b) The hazards that exist in handling

  10. Measured performance of a 3 ton LiBr absorption water chiller and its effect on cooling system operation

    Science.gov (United States)

    Namkoong, D.

    1976-01-01

    A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

  11. Measured performance of a 3-ton LiBr absorption water chiller and its effect on cooling system operation

    Science.gov (United States)

    Namkoong, D.

    1976-01-01

    A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

  12. Feasibility analysis of modified AL-6XN steel for structure component application in supercritical water-cooled reactor

    Institute of Scientific and Technical Information of China (English)

    Xinggang LI; Qingzhi YAN; Rong MA; Haoqiang WANG; Changchun GE

    2009-01-01

    Modified AL-6XN austenite steel was patterned after AL-6XN superaustenitic stainless steel by introducing microalloy elements such as zirconium and titanium in order to adapt to recrystallizing thermo-mechanical treatment and further improve crevice corrosion resistance. Modified AL-6XN exhibited comparable tensile strength, and superior plasticity and impact toughness to commercial AL-6XN steel. The effects of aging behavior on corrosion resistance and impact toughness were measured to evaluate the qualification of modified AL-6XN steel as an in-core component and cladding material in a supercritical water-cooled reactor. Attention should be paid to degradation in corrosion resistance and impact toughness after aging for 50 hours when modified AL-6XN steel is considered as one of the candidate materials for in-core components and cladding tubes in supercritical water-cooled reactors.

  13. Water Treatment Technology - Distribution Systems.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on distribution systems provides instructional materials for six competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pipe for distribution systems, types…

  14. Water Treatment Technology - Distribution Systems.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on distribution systems provides instructional materials for six competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pipe for distribution systems, types…

  15. Nanotechnology-based water treatment strategies.

    Science.gov (United States)

    Kumar, Sandeep; Ahlawat, Wandit; Bhanjana, Gaurav; Heydarifard, Solmaz; Nazhad, Mousa M; Dilbaghi, Neeraj

    2014-02-01

    The most important component for living beings on the earth is access to clean and safe drinking water. Globally, water scarcity is pervasive even in water-rich areas as immense pressure has been created by the burgeoning human population, industrialization, civilization, environmental changes and agricultural activities. The problem of access to safe water is inevitable and requires tremendous research to devise new, cheaper technologies for purification of water, while taking into account energy requirements and environmental impact. This review highlights nanotechnology-based water treatment technologies being developed and used to improve desalination of sea and brackish water, safe reuse of wastewater, disinfection and decontamination of water, i.e., biosorption and nanoadsorption for contaminant removal, nanophotocatalysis for chemical degradation of contaminants, nanosensors for contaminant detection, different membrane technologies including reverse osmosis, nanofiltration, ultrafiltration, electro-dialysis etc. This review also deals with the fate and transport of engineered nanomaterials in water and wastewater treatment systems along with the risks associated with nanomaterials.

  16. Internet Based, GIS Catalog of Non-Traditional Sources of Cooling Water for Use at America's Coal-Fired Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    J. Daniel Arthur

    2011-09-30

    In recent years, rising populations and regional droughts have caused coal-fired power plants to temporarily curtail or cease production due to a lack of available water for cooling. In addition, concerns about the availability of adequate supplies of cooling water have resulted in cancellation of plans to build much-needed new power plants. These issues, coupled with concern over the possible impacts of global climate change, have caused industry and community planners to seek alternate sources of water to supplement or replace existing supplies. The Department of Energy, through the National Energy Technology Laboratory (NETL) is researching ways to reduce the water demands of coal-fired power plants. As part of the NETL Program, ALL Consulting developed an internet-based Catalog of potential alternative sources of cooling water. The Catalog identifies alternative sources of water, such as mine discharge water, oil and gas produced water, saline aquifers, and publicly owned treatment works (POTWs), which could be used to supplement or replace existing surface water sources. This report provides an overview of the Catalog, and examines the benefits and challenges of using these alternative water sources for cooling water.

  17. Components and Treatments of Oilfield Produced Water

    Directory of Open Access Journals (Sweden)

    Essam Abdul-Jalil Saeed

    2010-01-01

    Full Text Available In this study, a review of variety of processes that are used in the treatment produced water prior to reuse or to responsible disposal are presented with their environmental issues and economical benefits. Samples of produced water from five locations in Rumaila oilfield/in south of Iraq were taken and analyzed for their contents of brine, some heavy metals, total suspended solids and oil and grease. Moreover, two samples of water were treated using reverse osmosis technique which showed its ability to treat such contaminated water. The results showed that the environmental impact of produced water arises from its chemical composition; i.e., its salt content, its heavy metals, and hydrocarbon contents.

  18. Natural Pathogen Control Chemistry to Replace Toxic Treatment of Microbes and Biofilm in Cooling Towers.

    Science.gov (United States)

    Brouse, Lon; Brouse, Richard; Brouse, Daniel

    2017-03-31

    Application of toxic antibacterial agents is considered necessary to control prevalent fresh water microorganisms that grow in evaporative cooling water systems, but can adversely affect the environment and human health. However, natural antibacterial water chemistry has been applied in industrial cooling water systems for over 10 years to inhibit microorganisms with excellent results. The water chemistry method concentrates natural minerals in highly-softened water to produce elevated pH and dissolved solids, while maintaining low calcium and magnesium content. The method provides further benefits in water conservation, and generates a small volume of non-toxic natural salt concentrate for cost efficient separation and disposal if required. This report describes the antimicrobial effects of these chemistry modifications in the cooling water environment and the resultant collective inhibition of microbes, biofilm, and pathogen growth. This article also presents a novel perspective of parasitic microbiome functional relationships, including "Trojan Protozoans" and biofilms, and the function of polyvalent metal ions in the formation and inhibition of biofilms. Reducing global dependence on toxic antibacterial agents discharged to the environment is an emerging concern due to their impact on the natural microbiome, plants, animals and humans. Concurrently, scientists have concluded that discharge of antibacterial agents plays a key role in development of pathogen resistance to antimicrobials as well as antibiotics. Use of natural antibacterial chemistry can play a key role in managing the cooling water environment in a more ecologically sustainable manner.

  19. The microscale cooling effects of water sensitive urban design and irrigation in a suburban environment

    Science.gov (United States)

    Broadbent, Ashley M.; Coutts, Andrew M.; Tapper, Nigel J.; Demuzere, Matthias; Beringer, Jason

    2017-09-01

    Prolonged drought has threatened traditional potable urban water supplies in Australian cities, reducing capability to adapt to climate change and mitigate against extreme. Integrated urban water management (IUWM) approaches, such as water sensitive urban design (WSUD), reduce the reliance on centralised potable water supply systems and provide a means for retaining water in the urban environment through stormwater harvesting and reuse. This study examines the potential for WSUD to provide cooling benefits and reduce human exposure and heat stress and thermal discomfort. A high-resolution observational field campaign, measuring surface level microclimate variables and remotely sensed land surface characteristics, was conducted in a mixed residential suburb containing WSUD in Adelaide, South Australia. Clear evidence was found that WSUD features and irrigation can reduce surface temperature (T s) and air temperature (T a) and improve human thermal comfort (HTC) in urban environments. The average 3 pm T a near water bodies was found to be up to 1.8 °C cooler than the domain maximum. Cooling was broadly observed in the area 50 m downwind of lakes and wetlands. Design and placement of water bodies were found to affect their cooling effectiveness. HTC was improved by proximity to WSUD features, but shading and ventilation were also effective at improving thermal comfort. This study demonstrates that WSUD can be used to cool urban microclimates, while simultaneously achieving other environmental benefits, such as improved stream ecology and flood mitigation.

  20. Reliability of chemical analyses of water samples

    Energy Technology Data Exchange (ETDEWEB)

    Beardon, R.

    1989-11-01

    Ground-water quality investigations require reliable chemical analyses of water samples. Unfortunately, laboratory analytical results are often unreliable. The Uranium Mill Tailings Remedial Action (UMTRA) Project`s solution to this problem was to establish a two phase quality assurance program for the analysis of water samples. In the first phase, eight laboratories analyzed three solutions of known composition. The analytical accuracy of each laboratory was ranked and three laboratories were awarded contracts. The second phase consists of on-going monitoring of the reliability of the selected laboratories. The following conclusions are based on two years experience with the UMTRA Project`s Quality Assurance Program. The reliability of laboratory analyses should not be taken for granted. Analytical reliability may be independent of the prices charged by laboratories. Quality assurance programs benefit both the customer and the laboratory.

  1. Reliability of chemical analyses of water samples

    Energy Technology Data Exchange (ETDEWEB)

    Beardon, R.

    1989-11-01

    Ground-water quality investigations require reliable chemical analyses of water samples. Unfortunately, laboratory analytical results are often unreliable. The Uranium Mill Tailings Remedial Action (UMTRA) Project`s solution to this problem was to establish a two phase quality assurance program for the analysis of water samples. In the first phase, eight laboratories analyzed three solutions of known composition. The analytical accuracy of each laboratory was ranked and three laboratories were awarded contracts. The second phase consists of on-going monitoring of the reliability of the selected laboratories. The following conclusions are based on two years experience with the UMTRA Project`s Quality Assurance Program. The reliability of laboratory analyses should not be taken for granted. Analytical reliability may be independent of the prices charged by laboratories. Quality assurance programs benefit both the customer and the laboratory.

  2. The Deep Cool Terrestrial Biosphere: Habitability of ancient fracture waters of the Canadian Shield (Invited)

    Science.gov (United States)

    Sherwood Lollar, B.; Ballentine, C. J.; Holland, G.; Li, L.; Slater, G. F.; Moser, D. P.

    2013-12-01

    waters and gases with conservative noble gases (He, Ne, Ar, Kr, Xe) provided bulk residence times on the order of billions of years [3]. These results for the first time suggest a realm of the Earth's hydrosphere that preserves a geochemical (and potentially microbial) environment minimally impacted by hydrogeological mixing with the surface over geologic time scales. Ongoing research is investigating the potential for microbial life in these waters, and the timing of life's penetration of these environments relative to the residence times of the fracture waters. These frontiers of the deep cool biosphere may provide a window into the Earth's biodiversity. The saline fracture waters provide a critical environment in which to investigate habitability and to determine whether the types of chemolithotrophic life recognized at the vents and hot springs are supported in the much larger segments of the Earth's crust where lower temperatures and hence slower rates of water-rock reaction prevail. The deepest fracture water may even provide the opportunity to investigate controls on the biotic-abiotic transition and limits to life in the deep Earth. [1] Lin et al. (2006) Science 314, 479-482. [2] Lippmann-Pipke et al. (2011) Chemical Geology 283, 287-296. [3] Holland et al. (2013) Nature 497, 357-360.

  3. Simulation of the solidification in a channel of a water-cooled glass flow

    Directory of Open Access Journals (Sweden)

    G. E. Ovando Chacon

    2014-12-01

    Full Text Available A computer simulation study of a laminar steady-state glass flow that exits from a channel cooled with water is reported. The simulations are carried out in a two-dimensional, Cartesian channel with a backward-facing step for three different angles of the step and different glass outflow velocities. We studied the interaction of the fluid dynamics, phase change and thermal behavior of the glass flow due to the heat that transfers to the cooling water through the wall of the channel. The temperature, streamline, phase change and pressure fields are obtained and analyzed for the glass flow. Moreover, the temperature increments of the cooling water are characterized. It is shown that, by reducing the glass outflow velocity, the solidification is enhanced; meanwhile, an increase of the step angle also improves the solidification of the glass flow.

  4. Thermal analysis and water-cooling design of the CSNS MEBT 324 MHz buncher cavity

    Institute of Scientific and Technical Information of China (English)

    LIU Hua-Chang; OUYANG Hua-Fu

    2008-01-01

    At least two bunchers are needed in the 3 MeV H- Medium Energy Beam Transport(MEBT)line located between RFQ and DTL for the CSNS(China Spallation Neutron Source).A nose-cone geometry has been adopted as the type of buncher cavity for its simplicity,higher impedance and lower risk of multipacting.By making use of the results got from the simulations on the buncher with two-dimension code SUPERFISH,the thermal and structural analyses have been carried out,the process and results to determine the resulting frequency shift due to thermal and structural distortion of the cavity are presented,the water-cooling channel position and the optimum cooling water temperature as well as the tuning method by adjusting the cooling water temperature when the cavity is out of resonance are also determined through the analyses.

  5. Thermal analysis and water-cooling design of the CSNS MEBT 324 MHz buncher cavity

    Science.gov (United States)

    Liu, Hua-Chang; Ouyang, Hua-Fu

    2008-04-01

    At least two bunchers are needed in the 3 MeV H- Medium Energy Beam Transport (MEBT) line located between RFQ and DTL for the CSNS (China Spallation Neutron Source). A nose-cone geometry has been adopted as the type of buncher cavity for its simplicity, higher impedance and lower risk of multipacting. By making use of the results got from the simulations on the buncher with two-dimension code SUPERFISH, the thermal and structural analyses have been carried out, the process and results to determine the resulting frequency shift due to thermal and structural distortion of the cavity are presented, the water-cooling channel position and the optimum cooling water temperature as well as the tuning method by adjusting the cooling water temperature when the cavity is out of resonance are also determined through the analyses.

  6. New Mexico cloud super cooled liquid water survey final report 2009.

    Energy Technology Data Exchange (ETDEWEB)

    Beavis, Nick; Roskovensky, John K.; Ivey, Mark D.

    2010-02-01

    Los Alamos and Sandia National Laboratories are partners in an effort to survey the super-cooled liquid water in clouds over the state of New Mexico in a project sponsored by the New Mexico Small Business Assistance Program. This report summarizes the scientific work performed at Sandia National Laboratories during the 2009. In this second year of the project a practical methodology for estimating cloud super-cooled liquid water was created. This was accomplished through the analysis of certain MODIS sensor satellite derived cloud products and vetted parameterizations techniques. A software code was developed to analyze multiple cases automatically. The eighty-one storm events identified in the previous year effort from 2006-2007 were again the focus. Six derived MODIS products were obtained first through careful MODIS image evaluation. Both cloud and clear-sky properties from this dataset were determined over New Mexico. Sensitivity studies were performed that identified the parameters which most influenced the estimation of cloud super-cooled liquid water. Limited validation was undertaken to ensure the soundness of the cloud super-cooled estimates. Finally, a path forward was formulized to insure the successful completion of the initial scientific goals which include analyzing different of annual datasets, validation of the developed algorithm, and the creation of a user-friendly and interactive tool for estimating cloud super-cooled liquid water.

  7. Ice water submersion for rapid cooling in severe drug-induced hyperthermia

    Science.gov (United States)

    Laskowski, Larissa K.; Landry, Adaira; Vassallo, Susi U.; Hoffman, Robert S.

    2015-01-01

    Context The optimal method of cooling hyperthermic patients is controversial. Although controlled data support ice water submersion, many authorities recommend a mist and fan technique. We report two patients with drug-induced hyperthermia, to demonstrate the rapid cooing rates of ice water submersion. Case details Case 1. A 27-year-old man presented with a sympathomimetic toxic syndrome and a core temperature of 41.4°C after ingesting 4-fluoroamphetamine. He was submerged in ice water and his core temperature fell to 38°C within 18 minutes (a mean cooling rate of 0.18°C/min). His vital signs stabilized, his mental status improved and he left on hospital day 2. Case 2. A 32-year-old man with a sympathomimetic toxic syndrome after cocaine use was transported in a body bag and arrived with a core temperature of 44.4°C. He was intubated, sedated with IV benzodiazepines, and submerged in ice water. After 20 minutes his temperature fell to 38.8°C (a cooling rate of 0.28°C/min). He was extubated the following day, and discharged on day 10. Discussion In these two cases, cooling rates exceeded those reported for mist and fan technique. Since the priority in hyperthermia is rapid cooling, clinical data need to be collected to reaffirm the optimal approach. PMID:25695144

  8. Experimental and numerical analysis of the cooling performance of water spraying systems during a fire.

    Directory of Open Access Journals (Sweden)

    YaoHan Chen

    Full Text Available The water spray systems are effective protection systems in the confined or unconfined spaces to avoid the damage to building structures since the high temperature when fires occur. NFPA 15 and 502 have suggested respectively that the factories or vehicle tunnels install water spray systems to protect the machinery and structures. This study discussed the cooling effect of water spray systems in experimental and numerical analyses. The actual combustion of woods were compared with the numerical simulations. The results showed that although the flame continued, the cooling effects by water spraying process within 120 seconds were obvious. The results also indicated that the simulation results of the fifth version Fire Dynamics Simulator (FDS overestimated the space temperature before water spraying in the case of the same water spray system.

  9. Experimental and numerical analysis of the cooling performance of water spraying systems during a fire.

    Science.gov (United States)

    Chen, YaoHan; Su, ChungHwei; Tseng, JoMing; Li, WunJie

    2015-01-01

    The water spray systems are effective protection systems in the confined or unconfined spaces to avoid the damage to building structures since the high temperature when fires occur. NFPA 15 and 502 have suggested respectively that the factories or vehicle tunnels install water spray systems to protect the machinery and structures. This study discussed the cooling effect of water spray systems in experimental and numerical analyses. The actual combustion of woods were compared with the numerical simulations. The results showed that although the flame continued, the cooling effects by water spraying process within 120 seconds were obvious. The results also indicated that the simulation results of the fifth version Fire Dynamics Simulator (FDS) overestimated the space temperature before water spraying in the case of the same water spray system.

  10. Air cooled absorption chillers for solar cooling applications

    Science.gov (United States)

    Biermann, W. J.; Reimann, R. C.

    1982-03-01

    The chemical composition of a 'best' absorption refrigerant system is identified, and those properties of the system necessary to design hot water operated, air cooled chilling equipment are determined. Air cooled chillers from single family residential sizes into the commercial rooftop size range are designed and operated.

  11. Public Health Risk Conditioned by Chemical Composition of Ground Water

    Science.gov (United States)

    Yankovich, E.; Osipova, N.; Yankovich, K.; Matveenko, I.

    2016-03-01

    The article studies the public health potential risk originated from water consumption and estimated on the basis of the groundwater chemical composition. We have processed the results of chemical groundwater analysis in different aquifers of Tomsk district (Tomsk Oblast, Russia). More than 8400 samples of chemical groundwater analyses were taken during long-term observation period. Human health risk assessment of exposure to contaminants in drinking water was performed in accordance with the risk assessment guidance for public health concerning chemical pollution of the environment (Russian reference number: 2.1.10.1920-04-M, 2004). Identified potential risks were estimated for consuming water of each aquifer. The comparative analysis of water quality of different aquifers was performed on the basis of the risk coefficient of the total non-carcinogenic effects. The non-carcinogenic risk for the health of the Tomsk district population due to groundwater consumption without prior sanitary treatment was admitted acceptable. A rather similar picture is observed for all aquifers, although deeper aquifers show lower hazard coefficients.

  12. Experiment Investigation on Electrical and Thermal Performances of a Semitransparent Photovoltaic/Thermal System with Water Cooling

    OpenAIRE

    Guiqiang Li; Gang Pei; Ming Yang; Jie Ji

    2014-01-01

    Different from the semitransparent building integrated photovoltaic/thermal (BIPV/T) system with air cooling, the semitransparent BIPV/T system with water cooling is rare, especially based on the silicon solar cells. In this paper, a semitransparent photovoltaic/thermal system (SPV/T) with water cooling was set up, which not only would provide the electrical power and hot water, but also could attain the natural illumination for the building. The PV efficiency, thermal efficiency, and exergy ...

  13. 78 FR 64029 - Cost-Benefit Analysis for Radwaste Systems for Light-Water-Cooled Nuclear Power Reactors

    Science.gov (United States)

    2013-10-25

    ... COMMISSION Cost-Benefit Analysis for Radwaste Systems for Light-Water-Cooled Nuclear Power Reactors AGENCY... Systems for Light-Water-Cooled Nuclear Power Reactors,'' in which the NRC made editorial corrections and... analysis for liquid and gaseous radwaste system components for light water nuclear power...

  14. Enhanced Homogeneities of Microstructure and Property in Al-Zn-Mg-Cu Extruded Product by Cooling Rate After Homogenization Treatment

    Science.gov (United States)

    Zhang, Zhihao; Xue, Jie; Jiang, Yanbin

    2017-07-01

    A method to improve the homogeneities of microstructure and mechanical property in an Al-Zn-Mg-Cu extruded product, which changes cooling rate after homogenization treatment to obtain the different distribution characteristics of the precipitates, was proposed and the microstructure evolution and mechanical properties of the alloy were investigated. The results show that the precipitates in the water-quenched billet are of mainly coarse particles with the content of about 2.0%, while a large number of needle-shaped precipitates are dispersively distributed in the furnace-cooled billet with the content of about 9.8%. Numerous precipitates distributed dispersively can improve the homogeneities of microstructure and mechanical property of the alloy during extrusion. For example, when the water-quenched billets are extruded at 390 and 430 °C followed by solution-aging treatment, the average grain sizes of the two bars are 3.4 and 8.1 μm, and the elongations to failure are 7.0 and 9.2%, respectively. When the furnace-cooled billets are extruded at 390 and 430 °C followed by solution-aging treatment, the average grain sizes of the two bars are 3.1 and 3.5 μm, respectively, and the elongations are basically the same, indicating the better microstructure homogeneity and mechanical properties.

  15. The Simulation of the Influence of Water Remnants on a Hot Rolled Plate after Cooling

    Directory of Open Access Journals (Sweden)

    Radek Zahradník

    2012-01-01

    Full Text Available In situations when a sheet metal plate of large dimensions is rolled, water remnants from cooling can be observed on the upper side of the plate. This paper focuses on deformations of a hot rolled sheet metal plate that are caused by water remnants after cooling. A transient finite element simulation was used to describe shape deformations of the cross profile of a metal sheet. The finite element model is fully parametric for easy simulation of multiple cases. The results from previous work were used for the boundary conditions.

  16. High Precision Temperature Control and Analysis of RF Deionized Cooling Water System

    CERN Document Server

    Tsai, Zong-Da; Chen June Rong; Liu, Chen-Yao

    2005-01-01

    Previously, the Taiwan Light Source (TLS) has proven the good beam quality mainly depends on the utility system stability. A serial of efforts were devoted to these studies. Further, a high precision temperature control of the RF deionized cooling water system will be achieved to meet the more critical stability requirement. The paper investigates the mixing mechanism through thermal and flow analysis and verifies the practical influences. A flow mixing mechanism and control philosophy is studied and processed to optimize temperature variation which has been reduced from ±0.1? to ±0.01?. Also, the improvement of correlation between RF performance and water cooling stability will be presented.

  17. Questioning the Mpemba effect: hot water does not cool more quickly than cold

    Science.gov (United States)

    Burridge, Henry C.; Linden, Paul F.

    2016-11-01

    The Mpemba effect is the name given to the assertion that it is quicker to cool water to a given temperature when the initial temperature is higher. This assertion seems counter-intuitive and yet references to the effect go back at least to the writings of Aristotle. Indeed, at first thought one might consider the effect to breach fundamental thermodynamic laws, but we show that this is not the case. We go on to examine the available evidence for the Mpemba effect and carry out our own experiments by cooling water in carefully controlled conditions. We conclude, somewhat sadly, that there is no evidence to support meaningful observations of the Mpemba effect.

  18. Ground water heat pumps and cooling with ground water basins as seasonal storage; Grundvandsvarmepumper og -koeling med grundvandsmagasiner som saesonlager

    Energy Technology Data Exchange (ETDEWEB)

    2008-04-15

    Ground water temperature is constant all the year round, in Denmark approximately 9 deg. C, which is ideal for a number of cooling purposes including cooling of buildings. The structures in which the ground water flows (sand, gravel and chalk) are efficient for storing coldness and heat over longer periods. By using seasonal storage of low-temperature heat and coldness in ground water layers close to the terrain it is feasible to reach profitable energy savings of up to 90% for cooling and heating of e.g. hotels, airports, shopping malls, office buildings and other larger buildings. At the same time the large energy savings means major reduction of CO{sub 2} emissions. (BA)

  19. Ground water heat pumps and cooling with ground water basins as seasonal storage; Grundvandsvarmepumper og -koeling med grundvandsmagasiner som saesonlager

    Energy Technology Data Exchange (ETDEWEB)

    2008-04-15

    Ground water temperature is constant all the year round, in Denmark approximately 9 deg. C, which is ideal for a number of cooling purposes including cooling of buildings. The structures in which the ground water flows (sand, gravel and chalk) are efficient for storing coldness and heat over longer periods. By using seasonal storage of low-temperature heat and coldness in ground water layers close to the terrain it is feasible to reach profitable energy savings of up to 90% for cooling and heating of e.g. hotels, airports, shopping malls, office buildings and other larger buildings. At the same time the large energy savings means major reduction of CO{sub 2} emissions. (BA)

  20. Water cooling thermal power measurement in a vacuum diffusion pump

    Directory of Open Access Journals (Sweden)

    Luís Henrique Cardozo Amorin

    2012-04-01

    Full Text Available Diffusion vacuum pumps are used both in industry and in laboratory science for high vacuum production. For its operation they must be refrigerated, and it is done by circulating water in open circuit. Considering that, vacuum systems stays operating by hours, the water consumption may be avoided if the diffusion vacuum pumps refrigeration were done in closed circuit. However, it is necessary to know the diffusion vacuum pump thermal power (the heat transferred to circulate water by time units to implement one of these and get in the refrigeration system dimension. In this paper the diffusion vacuum pump thermal power was obtained by measuring water flow and temperature variation and was calculated through the heat quantity variation equation time function. The thermal power value was 935,6 W, that is 397 W smaller and 35 W bigger than, respectively, the maximum and minimum diffusion pump thermal power suggested by its operation manual. This procedure have been shown useful to precisely determine the diffusion pump thermal power or of any other system that needs to be refrigerated in water closed circuit.

  1. Development and construction of the novel solar thermal desiccant cooling system incorporating hot water production

    Energy Technology Data Exchange (ETDEWEB)

    Enteria, Napoleon; Yoshino, Hiroshi; Mochida, Akashi; Takaki, Rie [Faculty of Engineering, Tohoku University, Sendai 980-8579 (Japan); Satake, Akira [Technical Research Institute, Maeda Corporation, Tokyo 179-8914 (Japan); Yoshie, Ryuichiro [Faculty of Engineering, Tokyo Polytechnic University, Atsugi 243-0297 (Japan); Baba, Seizo [Earth Clean Tohoku Co. Ltd., Sendai 984-0038 (Japan)

    2010-02-15

    This paper reports the development and construction of the novel solar cooling and heating system. The system consists of the thermal energy subsystem and the desiccant cooling subsystem. The system utilizes both the cheaper nighttime electric energy and the free daytime solar energy. The system is conceptualized to produce both cooling during summer daytime and hot water production during winter. Testing and evaluation of the system had been done to determine its operational procedure and performance. Based on the results, the thermal energy subsystem functioned to its expected performance in solar energy collection and thermal storage. The desiccant cooling subsystem reduced both the temperature and the humidity content of the air using solar energy with a minimal amount of back-up electric energy. The system however, needs further investigation under real conditions. (author)

  2. Cellulose nanomaterials in water treatment technologies.

    Science.gov (United States)

    Carpenter, Alexis Wells; de Lannoy, Charles-François; Wiesner, Mark R

    2015-05-05

    Cellulose nanomaterials are naturally occurring with unique structural, mechanical and optical properties. While the paper and packaging, automotive, personal care, construction, and textiles industries have recognized cellulose nanomaterials' potential, we suggest cellulose nanomaterials have great untapped potential in water treatment technologies. In this review, we gather evidence of cellulose nanomaterials' beneficial role in environmental remediation and membranes for water filtration, including their high surface area-to-volume ratio, low environmental impact, high strength, functionalizability, and sustainability. We make direct comparison between cellulose nanomaterials and carbon nanotubes (CNTs) in terms of physical and chemical properties, production costs, use and disposal in order to show the potential of cellulose nanomaterials as a sustainable replacement for CNTs in water treatment technologies. Finally, we comment on the need for improved communication and collaboration across the myriad industries invested in cellulose nanomaterials production and development to achieve an efficient means to commercialization.

  3. Influence of water quality on the embodied energy of drinking water treatment.

    Science.gov (United States)

    Santana, Mark V E; Zhang, Qiong; Mihelcic, James R

    2014-01-01

    Urban water treatment plants rely on energy intensive processes to provide safe, reliable water to users. Changes in influent water quality may alter the operation of a water treatment plant and its associated energy use or embodied energy. Therefore the objective of this study is to estimate the effect of influent water quality on the operational embodied energy of drinking water, using the city of Tampa, Florida as a case study. Water quality and water treatment data were obtained from the David L Tippin Water Treatment Facility (Tippin WTF). Life cycle energy analysis (LCEA) was conducted to calculate treatment chemical embodied energy values. Statistical methods including Pearson's correlation, linear regression, and relative importance were used to determine the influence of water quality on treatment plant operation and subsequently, embodied energy. Results showed that influent water quality was responsible for about 14.5% of the total operational embodied energy, mainly due to changes in treatment chemical dosages. The method used in this study can be applied to other urban drinking water contexts to determine if drinking water source quality control or modification of treatment processes will significantly minimize drinking water treatment embodied energy.

  4. Investigation of heat transfer for extruded polymers cooled in water

    CSIR Research Space (South Africa)

    Kumar, R

    2015-10-01

    Full Text Available part, the time taken by PE, PP and PLA to lose heat in water was analyzed theoretically with the help of MATLAB software package by taking into account the density, thermal conductivity, heat transfer coefficient and specific heat. The time taken...

  5. State of Fukushima nuclear fuel debris tracked by Cs137 in cooling water.

    Science.gov (United States)

    Grambow, B; Mostafavi, M

    2014-11-01

    It is still difficult to assess the risk originating from the radioactivity inventory remaining in the damaged Fukushima nuclear reactors. Here we show that cooling water analyses provide a means to assess source terms for potential future releases. Until now already about 34% of the inventories of (137)Cs of three reactors has been released into water. We found that the release rate of (137)Cs has been constant for 2 years at about 1.8% of the inventory per year indicating ongoing dissolution of the fuel debris. Compared to laboratory studies on spent nuclear fuel behavior in water, (137)Cs release rates are on the higher end, caused by the strong radiation field and oxidant production by water radiolysis and by impacts of accessible grain boundaries. It is concluded that radionuclide analyses in cooling water allow tracking of the conditions of the damaged fuel and the associated risks.

  6. Global cooling after the eruption of Mount Pinatubo: a test of climate feedback by water vapor.

    Science.gov (United States)

    Soden, Brian J; Wetherald, Richard T; Stenchikov, Georgiy L; Robock, Alan

    2002-04-26

    The sensitivity of Earth's climate to an external radiative forcing depends critically on the response of water vapor. We use the global cooling and drying of the atmosphere that was observed after the eruption of Mount Pinatubo to test model predictions of the climate feedback from water vapor. Here, we first highlight the success of the model in reproducing the observed drying after the volcanic eruption. Then, by comparing model simulations with and without water vapor feedback, we demonstrate the importance of the atmospheric drying in amplifying the temperature change and show that, without the strong positive feedback from water vapor, the model is unable to reproduce the observed cooling. These results provide quantitative evidence of the reliability of water vapor feedback in current climate models, which is crucial to their use for global warming projections.

  7. Cooling Effect of Water Injection on a High-Temperature Supersonic Jet

    Directory of Open Access Journals (Sweden)

    Jing Li

    2015-11-01

    Full Text Available The high temperature and high pressure supersonic jet is one of the key problems in the design of solid rocket motors. To reduce the jet temperature and noise, cooling water is typically injected into the exhaust plume. Numerical simulations for the gas-liquid multiphase flow field with mixture multiphase model were developed and a series of experiments were carried out. By introducing the energy source terms caused by the vaporization of liquid water into the energy equation, a coupling solution was developed to calculate the multiphase flow field. The temperature data predictions agreed well with the experimental results. When water was injected into the plume, the high temperature core region area was reduced, and the temperature on the head face was much lower than that without water. The relationship between the reduction of temperature on the bottom plate and the momentum ratio is developed, which can be used to predict the cooling effect of water injection in many cases.

  8. PARAMETERS OF WATER CIRCULATION NETWORK FOR A DISTRICT HEATING AND COOLING SYSTEM

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In a district heating and cooling system, i.e. Beijing combined heating cooling and power (CHCP) system studied here, high temperature water generated by two cogeneration plants circulates through a network between the plants and heat substations. At heat substations, supply water of high temperature from the network drives absorption chillers for air-conditioning in summer and meets space heating demands in winter or domestic hot water demands by heat exchangers in the whole year. The parameters, i.e. supply/return water temperature in the network, has a great impact on primary energy consumption (PEC) of the absorption chillers, circulation pumps and domestic hot water (DHW), which is studied in this paper.

  9. Performance of small water treatment plants: The case study of Mutshedzi Water Treatment Plant

    Science.gov (United States)

    Makungo, R.; Odiyo, J. O.; Tshidzumba, N.

    The performance of small water treatment plants (SWTPs) was evaluated using Mutshedzi WTP as a case study. The majority of SWTPs in South Africa (SA) that supply water to rural villages face problems of cost recovery, water wastages, limited size and semi-skilled labour. The raw and final water quality analyses and their compliance were used to assess the performance of the Mutshedzi WTP. Electrical conductivity (EC), pН and turbidity were measured in the field using a portable multimeter and a turbidity meter respectively. Atomic Absorption Spectrometry and Ion Chromatography were used to analyse metals and non-metals respectively. The results were compared with the Department of Water Affairs (DWA) guidelines for domestic use. The turbidity levels partially exceeded the recommended guidelines for domestic water use of 1 NTU. The concentrations of chemical parameters in final water were within the DWA guidelines for domestic water use except for fluoride, which exceeded the maximum allowable guideline of 1.5 mg/L in August 2009. Mutshedzi WTP had computed compliance for raw and final water analyses ranging from 79% to 93% and 86% to 93% throughout the sampling period, respectively. The results from earlier studies showed that the microbiological quality of final water in Mutshedzi WTP complied with the recommended guidelines, eliminating the slight chance of adverse aesthetic effects and infectious disease transmission associated with the turbidity values between 1 and 5 NTU. The study concluded that Mutshedzi WTP, though moving towards compliance, is still not producing adequate quality of water. Other studies also indicated that the quantity of water produced from Mutshedzi WTP was inadequate. The findings of the study indicate that lack of monitoring of quantity of water supplied to each village, dosage of treatment chemicals, the treatment capacity of the WTP and monitoring the quality of water treated are some of the factors that limit the performance of

  10. Passive sampling of perfluorinated chemicals in water: Flow rate effects on chemical uptake

    NARCIS (Netherlands)

    Kaserzon, S.L.; Vermeirssen, E.L.M.; Hawker, D.W.; Kennedy, K.; Bentley, C.; Thompson, J.; Booij, K.; Mueller, J.F.

    2013-01-01

    A recently developed modified polar organic chemical integrative sampler (POCIS) provides a means for monitoring perfluorinated chemicals (PFCs) in water. However, changes in external flow rates may alter POCIS sampling behaviour and consequently affect estimated water concentrations of analytes. In

  11. Studies on advanced water-cooled reactors beyond generation Ⅲ for power generation

    Institute of Scientific and Technical Information of China (English)

    CHENG Xu

    2007-01-01

    China's ambitious nuclear power program motivates the country's nuclear community to develop advanced reactor concepts beyond generation Ⅲ to ensure a long-term, stable, and sustainable development of nuclear power. The paper discusses some main criteria for the selection of future water-cooled reactors by considering the specific Chinese situation. Based on the suggested selection criteria, two new types of water-cooled reactors are recommended for future Chinese nuclear power generation. The high conversion pressurized water reactor utilizes the present PWR technology to a large extent. With a conversion ratio of about 0.95, the fuel utilization is increased about 5 times. This significantly improves the sustainability of fuel resources. The supercritical water-cooled reactor has favorable features in economics,sustainability and technology availability. It is a logical extension of the generation Ⅲ PWR technology in China.The status of international R&D work is reviewed. A new supercritieal water-cooled reactor (SCWR) core structure (the mixed reactor core) and a new fuel assembly design (two-rows FA) are proposed. The preliminary analysis using a coupled neutron-physics/thermal-hydranlics method is carded out. It shows good feasibility for the new design proposal.

  12. Application of Pulsed Electrical Fields for Advanced Cooling and Water Recovery in Coal-Fired Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Young Cho; Alexander Fridman

    2009-04-02

    The overall objective of the present work was to develop technologies to reduce freshwater consumption in a cooling tower of coal-based power plant so that one could significantly reduce the need of make-up water. The specific goal was to develop a scale prevention technology based an integrated system of physical water treatment (PWT) and a novel filtration method so that one could reduce the need for the water blowdown, which accounts approximately 30% of water loss in a cooling tower. The present study investigated if a pulsed spark discharge in water could be used to remove deposits from the filter membrane. The test setup included a circulating water loop and a pulsed power system. The present experiments used artificially hardened water with hardness of 1,000 mg/L of CaCO{sub 3} made from a mixture of calcium chloride (CaCl{sub 2}) and sodium carbonate (Na{sub 2}CO{sub 3}) in order to produce calcium carbonate deposits on the filter membrane. Spark discharge in water was found to produce strong shockwaves in water, and the efficiency of the spark discharge in cleaning filter surface was evaluated by measuring the pressure drop across the filter over time. Results showed that the pressure drop could be reduced to the value corresponding to the initial clean state and after that the filter could be maintained at the initial state almost indefinitely, confirming the validity of the present concept of pulsed spark discharge in water to clean dirty filter. The present study also investigated the effect of a plasma-assisted self-cleaning filter on the performance of physical water treatment (PWT) solenoid coil for the mitigation of mineral fouling in a concentric counterflow heat exchanger. The self-cleaning filter utilized shockwaves produced by pulse-spark discharges in water to continuously remove scale deposits from the surface of the filter, thus keeping the pressure drop across the filter at a relatively low value. Artificial hard water was used in the

  13. Structure of Water Mist Stream and its Impact on Cooling Efficiency of Casting Die

    Directory of Open Access Journals (Sweden)

    R. Władysiak

    2012-04-01

    Full Text Available The work is a continuation of research on the use water mist cooling in order to increase efficiency of die-casting aluminum alloys. The paper presents results of research and analysis process, spraying water and generated a stream of water mist, the effect of the type of nozzle, the nozzle size and shape of the emitting of the water mist on the wall surface of casting die on the microstructure and geometry of water mist stream and cooling efficiency. Tests were used to perform high-speed camera to record video in the visible and infrared camera. Results were used to develop a computerized image analysis and statistical analysis. The study showed that there are statistical relationships between water and air flow and geometry of the nozzle and nozzle emitting a stream of microstructure parameters of water mist and heat the incoming stream. These relationships are described mathematical models that allow you to control the generating of adequate stream of water mist and a further consequence, the cooling efficiency of casting die.

  14. Advanced treatment and reuse system developed for oilfield process water

    Energy Technology Data Exchange (ETDEWEB)

    Conroy, Kevin

    2011-01-15

    An innovative plant to treat oilfield produced wastewater is being constructed in Trinidad and Tobago following recent regulations and industrial water supply challenges. The 4,100m3/day treatment system, developed by Golder Associates, will produce water for industrial reuse and effluent that meets new regulations. The treatment stages include: oil-water separation by gravity, equalization with a two-day capacity basin, dissolved air flotation, cooling, biotreatment/settling with immobilized cell bioreactors (ICB) technology, prefiltration/reverse osmosis and effluent storage/transfer. This advanced system will provide several important benefits including the elimination of inland discharge of minimally-treated water and the reduction of environmental and public health concerns. In addition, it will provide a new source of industrial water, resulting in a decrease in demand for fresh water. The success of this plant could lead to additional facilities in other oil field locations, expanding economic and environmental benefits of water reuse.

  15. Effect of organic on chemical oxidation for biofouling control in pilot-scale seawater cooling towers

    KAUST Repository

    Al-Bloushi, Mohammed

    2017-09-14

    Due to the scarcity of potable water in many regions of the world, the demand for seawater as an alternative evaporative cooling medium in cooling towers (CTs) has increased significantly in recent years. Seawater make-up in CTs is deemed the most feasible because of its unlimited supply in the coastal areas of Gulf and Red Sea. However, the seawater CTs have higher challenges greatly mitigating their performances because it is an open system where biofouling and bio-corrosion occurring within the fillers and piping of recirculation systems. Their pilot-scale CTs were constructed to assess the performance of three types of oxidizing biocides or oxidants, namely chlorine, chlorine dioxide (ClO2) and ozone, for biofouling control. The test results showed that the addition of organic (5mg/L of methanol (MeOH)) increased the bacterial growth in CT basin. All oxidants were effective in keeping the microbial growth to the minimum. Oxidation increased the oxidation-reduction potential (ORP) level from 270 to 600mV. Total residual oxidant (TRO) was increased with oxidation but it was slightly increased with organic addition. Other parameters including pH, dissolved oxygen (DO), conductivity levels were not changed. However, higher formation of disinfection by-products (DBPs) was detected with chlorination and ozonation. This indicates the organic level should be limited in the oxidation for biofouling control in seawater CTs.

  16. [Evidence for emergency treatment of chemical eye burns].

    Science.gov (United States)

    Laursen, Jonas Vejvad Nørskov; Hjortdal, Jesper Østergaard

    2014-01-01

    The purpose of this article was to review the existing evidence on emergency treatment of chemical eye burns. Clinical studies show that patients receiving prompt eye irrigation after chemical burns had a significantly better clinical outcome. This is further collaborated in animal studies where prompt irrigation with diphoterine or borate buffer significantly lowered pH in the eye after alkali burns. Two of three studies showed that tap water significantly lowered pH as well, but only if it was administered within 60 seconds after exposure. Saline, however, did not cause any significant decrease in pH at all.

  17. Ultrafast cooling by covalently bonded graphene-carbon nanotube hybrid immersed in water

    Science.gov (United States)

    Chen, Jie; Walther, Jens H.; Koumoutsakos, Petros

    2016-11-01

    The increasing power density and the decreasing dimensions of transistors present severe thermal challenges to the design of modern microprocessors. Furthermore, new technologies such as three-dimensional chip-stack architectures require novel cooling solutions for their thermal management. Here, we demonstrate, through transient heat-dissipation simulations, that a covalently bonded graphene-carbon nanotube (G-CNT) hybrid immersed in water is a promising solution for the ultrafast cooling of such high-temperature and high heat-flux surfaces. The G-CNT hybrid offers a unique platform to integrate the superior axial heat transfer capability of individual CNTs via their parallel arrangement. The immersion of the G-CNT in water enables an additional heat dissipation path via the solid-liquid interaction, allowing for the sustainable cooling of the hot surface under a constant power input of up to 10 000 W cm-2.

  18. Influence of the Water-Cooled Heat Exchanger on the Performance of a Pulse Tube Refrigerator

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2017-02-01

    Full Text Available The water-cooled heat exchanger is one of the key components in a pulse tube refrigerator. Its heat exchange effectiveness directly influences the cooling performance of the refrigerator. However, effective heat exchange does not always result in a good performance, because excessively reinforced heat exchange can lead to additional flow loss. In this paper, seven different water-cooled heat exchangers were designed to explore the best configuration for a large-capacity pulse tube refrigerator. Results indicated that the heat exchanger invented by Hu always offered a better performance than that of finned and traditional shell-tube types. For a refrigerator with a working frequency of 50 Hz, the best hydraulic diameter is less than 1 mm.

  19. Water chemistry in heat and cold supply (district heating/cooling)

    Energy Technology Data Exchange (ETDEWEB)

    Deelen-Bremer, Marga van; Vos, Frank de; Heijboer, Rob [KEMA Nederland B.V. (Netherlands)

    2010-07-01

    District heating is seen as an important pillar in the CO{sub 2} reduction. Since the Kyoto protocol with the target for reduction of greenhouse gases, a renewed interest in district heating is visible. District heating and increasingly district cooling can be used for heating/cooling of houses, but also for large buildings and greenhouses. Combined heat and power (CHP), waste incinerator, but also rest heat of industry can provide the heat for district heating. On the other hand cold surface water, groundwater, but also rest heat can be used for district cooling. With the growing heat/cold supply market, also an even larger growth in cases of damages in district heating systems is wittnessed. Damages were chemistry can play an preventing role. A good conditioning of the district heating water, combined with proper monitoring, will safeguard the integrity of the system. (orig.)

  20. Engineering Characteristics of Chemically Treated Water-Repellent Kaolin.

    Science.gov (United States)

    Choi, Youngmin; Choo, Hyunwook; Yun, Tae Sup; Lee, Changho; Lee, Woojin

    2016-12-02

    Water-repellent soils have a potential as alternative construction materials that will improve conventional geotechnical structures. In this study, the potential of chemically treated water-repellent kaolin clay as a landfill cover material is explored by examining its characteristics including hydraulic and mechanical properties. In order to provide water repellency to the kaolin clay, the surface of clay particle is modified with organosilanes in concentrations (CO) ranging from 0.5% to 10% by weight. As the CO increases, the specific gravity of treated clay tends to decrease, whereas the total organic carbon content of the treated clay tends to increase. The soil-water contact angle increases with an increase in CO until CO = 2.5%, and then maintains an almost constant value (≈134.0°). Resistance to water infiltration is improved by organosilane treatment under low hydrostatic pressure. However, water infiltration resistance under high hydrostatic pressure is reduced or exacerbated to the level of untreated clay. The maximum compacted dry weight density decreases with increasing CO. As the CO increases, the small strain shear modulus increases, whereas the effect of organosilane treatment on the constrained modulus is minimal. The results indicate that water-repellent kaolin clay possesses excellent engineering characteristics for a landfill cover material.

  1. Engineering Characteristics of Chemically Treated Water-Repellent Kaolin

    Directory of Open Access Journals (Sweden)

    Youngmin Choi

    2016-12-01

    Full Text Available Water-repellent soils have a potential as alternative construction materials that will improve conventional geotechnical structures. In this study, the potential of chemically treated water-repellent kaolin clay as a landfill cover material is explored by examining its characteristics including hydraulic and mechanical properties. In order to provide water repellency to the kaolin clay, the surface of clay particle is modified with organosilanes in concentrations (CO ranging from 0.5% to 10% by weight. As the CO increases, the specific gravity of treated clay tends to decrease, whereas the total organic carbon content of the treated clay tends to increase. The soil-water contact angle increases with an increase in CO until CO = 2.5%, and then maintains an almost constant value (≈134.0°. Resistance to water infiltration is improved by organosilane treatment under low hydrostatic pressure. However, water infiltration resistance under high hydrostatic pressure is reduced or exacerbated to the level of untreated clay. The maximum compacted dry weight density decreases with increasing CO. As the CO increases, the small strain shear modulus increases, whereas the effect of organosilane treatment on the constrained modulus is minimal. The results indicate that water-repellent kaolin clay possesses excellent engineering characteristics for a landfill cover material.

  2. Chemical composition of water from roofs in Gdansk, Poland

    Energy Technology Data Exchange (ETDEWEB)

    Tsakovski, Stefan, E-mail: stsakovski@chem.uni-sofia.b [Chair of Physical Chemistry, Faculty of Chemistry, University of Sofia, J Bourchier Blvd. 1, 1164 Sofia (Bulgaria); Tobiszewski, Marek [Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology (GUT), 11/12 G. Narutowicza St., 80-952 Gdansk (Poland); Simeonov, Vasil, E-mail: vsimeonov@chem.uni-sofia.b [Chair of Analytical Chemistry, Faculty of Chemistry, University of Sofia, 1164 Sofia (Bulgaria); Polkowska, Zaneta [Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology (GUT), 11/12 G. Narutowicza St., 80-952 Gdansk (Poland); Namiesnik, Jacek, E-mail: chemanal@pg.gda.p [Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology (GUT), 11/12 G. Narutowicza St., 80-952 Gdansk (Poland)

    2010-01-15

    This study deals with the assessment of roof runoff waters from the region of Gdansk collected during the winter season (2007/2008). The chemical analysis includes 16 chemical variables: major ions, PAHs and PCBs measured at 3 sampling sites for 6-14 rain events. Although the data set is of limited volume the statistical data treatment using self-organizing maps (SOM) reveals the main factors controlling roof runoff water quality even for a data set with small dimension. This effort for explanation of the identified factors by the possible emission sources of the urban environment and air-particulate formation seems to be very reliable. Additionally to the roof runoff water quality factors the rain events patterns are found: 'background' group of events and groups formally named 'PAHs', 'PCBs' and 'air-borne particles' - dominated events. The SOM classification results give an opportunity to uncover the role of roof 'impact' on the runoff waters. Rain runoff water quality is described by four latent factors and the 'roof' impact is uncovered. - Identification of the urban roof runoff water quality factors and 'roof' impact by self-organizing map classification.

  3. THE SOLUTION TO THE PROBLEM OF USING GROUND WATER TO COOL LIVESTOCK BUILDINGS

    Directory of Open Access Journals (Sweden)

    Thay Ngok Shon

    2017-01-01

    Full Text Available Ambient temperature in the central part of Vietnam in summer can reach 32–35°C; in some places it can be more than 42°C. Hot climate strongly affects the animal organism alongside with the animal weight reduction and reduction the quantity of egg-laying in poultry. Therefore, air conditioning in livestock buildings is necessary. There are several ways to cool the temperature in such buildings, and each one has its own advantages and disadvantages. We propose to use underground water at the temperature of 24–25°C for this purpose. One of the methods of cooling sheds for livestock is sprinkler irrigation of water on the roof. For calculating the amount of heat, removed from the indoor air in the shed to the cooling water, in the first approximation specialists believe in some cases that an appropriate amount of heat being removed is determined mainly by heat transfer from the air inside the shed to the cooling water through the surface of the roof, represented by the lower part of the wave that form the surface of a metal tile, neglecting the influence of heat conduction on top of the wave of the tile surface. Consequentially, such a simplification leads to possible errors. Therefore, the authors solved the problem of cooling shed by irrigation of water on the roof by an analytical method. Specifically, we solved the problem of heat conductivity of the fin of the finite length of constant cross section, wherein different sides of the fin are conjugate with different environments. Additionally, the calculation considered the effect of solar radiation. For this purpose, the authors have created a heat balance equation at steady state for any infinitesimal element of the fin, and solved the differential equation afterwards. The authors applied the results for calculating practical problem of ground water irrigation of a roof of a livestock shed made of metal areas tiles. 

  4. The impact of thermal treatment and cooling methods on municipal solid waste incineration bottom ash with an emphasis on Cl.

    Science.gov (United States)

    Yang, Shuo; Saffarzadeh, Amirhomayoun; Shimaoka, Takayuki; Kawano, Takashi; Kakuta, Yoshitada

    2016-10-01

    Municipal solid waste incineration (MSWI) bottom-ash products possess qualifications to be utilized in cement production. However, the instant use of bottom ash is inhibited by a number of factors, among which the chlorine (Cl) content is always strictly restricted. In this paper, the unquenched MSWI bottom ash was used as the experimental substance, and the influences of thermal treatment and cooling methods on the content and existence of Cl in the ash residues were investigated. The characterization of the MSWI bottom-ash samples examined by utilizing X-ray diffraction, optical microscopy, scanning electron microscopy/energy dispersive X-ray spectroscopy. The experimental results show that as a function of thermal treatment, the reduction rate of Cl is slight below 15.0%, which is relatively low compared with water washing process. Different cooling methods had impacts on the existing forms of Cl. It was understood that most of Cl existed in the glass phase if the bottom ash was air cooled. Contrarily in case of water-quenched bottom ash, Cl could also be accumulated in the newly-formed quench products as chloride salts or hydrate substances such as Friedel's salt.

  5. 40 CFR 63.1086 - How must I monitor for leaks to cooling water?

    Science.gov (United States)

    2010-07-01

    ... electrode monitoring, pH, conductivity, or other representative indicators. (1) You shall prepare and... cooling water using any method listed in 40 CFR part 136. Use the same method for both entrance and exit samples. You may validate 40 CFR part 136 methods for the HAP listed in Table 1 to this subpart...

  6. Numerical simulation of endovenous laser treatment of the incompetent great saphenous vein with external air cooling.

    Science.gov (United States)

    Marqa, Mohamad Feras; Mordon, Serge; Hernández-Osma, Esteban; Trelles, Mario; Betrouni, Nacim

    2013-05-01

    Endovenous laser treatment (ELT) has been proposed as an alternative in the treatment of reflux of the great saphenous vein. Before the procedure, peri-saphenous subcutaneous tumescent saline solution infiltration is usually performed. However, diffusion of this tumescent fluid is rapidly observed and can potentially reduce the efficacy as a heat sink. External skin cooling with cold air was proposed as an alternative solution. The objective of this study is to compare endovenous laser treatment without and with air cooling by realistic numerical simulations. An optical-thermal damage model was formulated and implemented using finite element modeling. The general model simulated light distribution using the diffusion approximation of the transport theory, temperature rise using the bioheat equation, and laser-induced injury using the Arrhenius damage model. Parameters, used in clinical procedures, were considered: power, 15 W; pulse duration, 1 s; fiber pull back, 3-mm increments every second; cold air applied in continuous mode during ELT; and no tumescent anesthesia. Simulations were performed for vein locations at 5, 10, and 15 mm in depth, with and without air cooling. For a vein located at 15 mm in depth, no significant difference was observed with and without cooling. For a vein located at 10 mm in depth, surface temperature increase up to 45 °C is observed without cooling. For a vein located at 5 mm, without cooling, temperature increase leads to irreversible damage of dermis and epidermis. Conversely, with air cooling, surface temperature reaches a maximum of 38 °C in accordance with recordings performed on patients. ELT of the incompetent great saphenous vein with external air cooling system is a promising therapy technique. Use of cold air on the skin continuously flowing in the area of laser shot decreased significantly the heat extent and the thermal damage in the perivenous tissues and the skin.

  7. Treatment of LF slag to prevent powdering during cooling

    Directory of Open Access Journals (Sweden)

    Ghorai S.

    2017-01-01

    Full Text Available The polymorphic transformation of the monoclinic β-polymorph to the orthorhombic γ-polymorph of di-calcium silicate at around 500°C during cooling results in disintegration of slag. The slag generated, during the production of thermo mechanically treated steel in ladle furnace at M/s Tata Steel Limited, Jamshedpur, India, behaves in similar manner. An attempt has been made to prevent the crumbling of ladle furnace slag. The experiments were conducted in 10 kg air induction furnace. Various types of silica source were used to prevent the disintegration of ladle furnace slag by reducing the basicity and optimizing the additives amount. Apart from silica sources, other additives like borax and barium carbonate were also used to stabilize the β phase. Present investigation reveals that disintegration of ladle furnace slag can be prevented either by addition of 0.2% boarx or 2% barium carbonate. Dust formation can also be prevented by decreasing the ladle furnace slag basicity to about 1.7. Toxicity Characteristic Leaching Procedure test, of the borax and barium carbonate treated slag samples, indicates that barium carbonate treated slag cannot be used for the dusting prevention as it contains high level of barium.

  8. A water-cooling solution for PC-racks of the LHC experiments

    CERN Document Server

    Vannerem, P

    2004-01-01

    With ever increasing power consumption and heat dissipation of todays CPUs, cooling of rack-mounted PCs is an issue for the future online farms of the LHC experiments. In order to investigate the viability of a water-cooling solution, a prototype PC-farm rack has been equipped with a commercially available retrofitted heat exchanger. The project has been carried out as a collaboration of the four LHC experiments and the PH-ESS group . This note reports on the results of a series of cooling and power measurements of the prototype rack with configurations of 30 to 48 PCs. The cooling performance of the rack-cooler is found to be adequate; it extracts the heat dissipated by the CPUs efficiently into the cooling water. Hence, the closed PC rack transfers almost no heat into the room. The measurements and the failure tests show that the rack-cooler concept is a viable solution for the future PC farms of the LHC experiments.

  9. Reduction of Fire Hazard in Materials for Irrigators and Water Collectors in Cooling Towers

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, N. V.; Konstantinova, N. I., E-mail: konstantinova-n@inbox.ru [FGBU VNIIPO of EMERCOM of Russia (All-Russian Scientific-research Institute of Fire Protection) (Russian Federation); Gordon, E. P. [Research and Production Center “Kaustik” (Russian Federation); Poedintsev, E. A. [FGBU VNIIPO of EMERCOM of Russia (All-Russian Scientific-research Institute of Fire Protection) (Russian Federation)

    2016-09-15

    A way of reducing the fire hazard of PVC film used to make cooling-tower irrigators and water collectors is examined. A new generation of fire retardant, nanostructured magnesium hydroxide, is used to impart fire retardant properties. The fabrication technology is optimized with a roller-calendering manufacturing technique, and the permissible ranges of fire hazard indicators for materials in irrigators and water collectors are determined.

  10. Surface Water Treatment Workshop Manual.

    Science.gov (United States)

    Ontario Ministry of the Environment, Toronto.

    This manual was developed for use at workshops designed to increase the knowledge of experienced water treatment plant operators. Each of the fourteen lessons in this document has clearly stated behavioral objectives to tell the trainee what he should know or do after completing that topic. Areas covered in this manual include: basic water…

  11. CFD in drinking water treatment

    NARCIS (Netherlands)

    Wols, B.A.

    2010-01-01

    Hydrodynamic processes largely determine the efficacy of drinking water treatment systems, in particular disinfection systems. A lack of understanding of the hydrodynamics has resulted in suboptimal designs of these systems. The formation of unwanted disinfection-by-products and the energy consumpti

  12. CFD in drinking water treatment

    NARCIS (Netherlands)

    Wols, B.A.

    2010-01-01

    Hydrodynamic processes largely determine the efficacy of drinking water treatment systems, in particular disinfection systems. A lack of understanding of the hydrodynamics has resulted in suboptimal designs of these systems. The formation of unwanted disinfection-by-products and the energy consumpti

  13. CFD in drinking water treatment

    NARCIS (Netherlands)

    Wols, B.A.

    2010-01-01

    Hydrodynamic processes largely determine the efficacy of drinking water treatment systems, in particular disinfection systems. A lack of understanding of the hydrodynamics has resulted in suboptimal designs of these systems. The formation of unwanted disinfection-by-products and the energy

  14. Reuse of Treated Internal or External Wastewaters in the Cooling Systems of Coal-Based Thermoelectric Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Radisav Vidic; David Dzombak; Ming-Kai Hsieh; Heng Li; Shih-Hsiang Chien; Yinghua Feng; Indranil Chowdhury; Jason Monnell

    2009-06-30

    This study evaluated the feasibility of using three impaired waters - secondary treated municipal wastewater, passively treated abandoned mine drainage (AMD), and effluent from ash sedimentation ponds at power plants - for use as makeup water in recirculating cooling water systems at thermoelectric power plants. The evaluation included assessment of water availability based on proximity and relevant regulations as well as feasibility of managing cooling water quality with traditional chemical management schemes. Options for chemical treatment to prevent corrosion, scaling, and biofouling were identified through review of current practices, and were tested at bench and pilot-scale. Secondary treated wastewater is the most widely available impaired water that can serve as a reliable source of cooling water makeup. There are no federal regulations specifically related to impaired water reuse but a number of states have introduced regulations with primary focus on water aerosol 'drift' emitted from cooling towers, which has the potential to contain elevated concentrations of chemicals and microorganisms and may pose health risk to the public. It was determined that corrosion, scaling, and biofouling can be controlled adequately in cooling systems using secondary treated municipal wastewater at 4-6 cycles of concentration. The high concentration of dissolved solids in treated AMD rendered difficulties in scaling inhibition and requires more comprehensive pretreatment and scaling controls. Addition of appropriate chemicals can adequately control corrosion, scaling and biological growth in ash transport water, which typically has the best water quality among the three waters evaluated in this study. The high TDS in the blowdown from pilot-scale testing units with both passively treated mine drainage and secondary treated municipal wastewater and the high sulfate concentration in the mine drainage blowdown water were identified as the main challenges for blowdown

  15. Sonication for advanced drinking water treatment

    Institute of Scientific and Technical Information of China (English)

    ZHANG Guang-ming; WEI Xi-zhu; LI Xiang-kun; ZHANG Jie; DOU Zi-bo

    2009-01-01

    This paper investigated the feasibility of sonication as an advanced treatment method for drinking water production and used comprehensive indexes of water quality to examine its efficiency. Results show that sonication significantly reduces the toxicity of water. Sonication with 5 W/L at 90 kHz lasting for 30 min decreases he water SUVA and the disinfection byproduct formation potential (DBPFP) by 38.7% and 27.2% respective ly. Sonieation also decreases the UV254 by more than 50% through destroying unsaturated chemical bonds.Higher sound intensity and higher frequency benefit the reduction of TOC and UV254, Besides, sonication significantly increases the affinity of organics with granular activated carbon (GAC), and thus the hybrid sonication-GAC method reduces the water TOC, COD, UV254, and DBPFP by 78. 3%, 69.4%, 75.7%, and 70. 0% respectively. Therefore, sonieation and the hybrid sonieation-GAC method are proposed as advanced treatment methods for drinking water.

  16. Characterization of N-Acylhomoserine Lactones Produced by Bacteria Isolated from Industrial Cooling Water Systems

    Directory of Open Access Journals (Sweden)

    Noriya Okutsu

    2015-12-01

    Full Text Available The cooling water systems are used to remove heat generated in the various industries. Biofouling of the cooling water systems causes blocking of condenser pipes and the heat exchanger tubes. In many Gram-negative bacteria, N-acylhomoserine lactone (AHL are used as quorum-sensing signal molecule and associated with biofilm formation. To investigate the relationship between quorum sensing and biofouling in the cooling water system, we isolated a total of 192 bacterial strains from the five cooling water systems, and screened for AHL production. Seven isolates stimulated AHL-mediated purple pigment production in AHL reporter strain Chromobacterium violaceum CV026 or VIR07. Based on their 16S rRNA gene sequences, AHL-producing isolates were assigned to Aeromonas hydrophila, Lysobacter sp., Methylobacterium oryzae, and Bosea massiliensis. To the best of our knowledge, B. massiliensis and Lysobacter sp. have not been reported as AHL-producing species in the previous researches. AHLs extracted from the culture supernatants of B. massiliensis and Lysobacter sp. were identified by liquid chromatography-mass spectrometry. AHLs produced by B. massiliensis were assigned as N-hexanoyl-l-homoserine lactone (C6-HSL, N-(3-oxohexanoyl-l-homoserine lactone (3-oxo-C6-HSL, and N-(3-oxooctanoyl-l-homoserine lactone (3-oxo-C8-HSL. AHLs produced by Lysobacter sp. were assigned as N-decanoyl-l-homoserine lactone (C10-HSL and N-(3-oxodecanoyl-l-homoserine lactone (3-oxo-C10-HSL. This is the first report of identification of AHLs produced by B. massiliensis and Lysobacter sp. isolated from the cooling water system.

  17. Patterns of fish assemblage structure and dynamics in waters of the Savannah River Plant. Comprehensive Cooling Water Study final report

    Energy Technology Data Exchange (ETDEWEB)

    Aho, J.M.; Anderson, C.S.; Floyd, K.B.; Negus, M.T.; Meador, M.R.

    1986-06-01

    Research conducted as part of the Comprehensive Cooling Water Study (CCWS) has elucidated many factors that are important to fish population and community dynamics in a variety of habitats on the Savannah River Plant (SRP). Information gained from these studies is useful in predicting fish responses to SRP operations. The overall objective of the CCWS was (1) to determine the environmental effects of SRP cooling water withdrawals and discharges and (2) to determine the significance of the cooling water impacts on the environment. The purpose of this study was to: (1) examine the effects of thermal plumes on anadromous and resident fishes, including overwintering effects, in the SRP swamp and associated tributary streams; (2) assess fish spawning and locate nursery grounds on the SRP; (3) examine the level of use of the SRP by spawning fish from the Savannah River, this objective was shared with the Savannah River Laboratory, E.I. du Pont de Nemours and Company; and (4) determine impacts of cooling-water discharges on fish population and community attributes. Five studies were designed to address the above topics. The specific objectives and a summary of the findings of each study are presented.

  18. Effect of makeup water properties on the condenser fouling in power planr cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Safari, I.; Walker, M.; Abbasian, J.; Arastoopour, H.; Hsieh, M-K.; Dzombak, D.; Miller, D.

    2011-01-01

    The thermoelectric power industry in the U.S. uses a large amount of fresh water. As available freshwater for use in thermoelectric power production becomes increasingly limited, use of nontraditional water sources is of growing interest. Utilization of nontraditional water, in cooling systems increases the potential for mineral precipitation on heat exchanger surfaces. In that regard, predicting the accelerated rate of scaling and fouling in condenser is crucial to evaluate the condenser performance. To achieve this goal, water chemistry should be incorporated in cooling system modeling and simulation. This paper addresses the effects of various makeup water properties on the cooling system, namely pH and aqueous speciation, both of which are important factors affecting the fouling rate in the main condenser. Detailed modeling of the volatile species desorption (i.e. CO{sub 2} and NH{sub 3}), the formation of scale in the recirculating system, and the relationship between water quality and the corresponding fouling rates is presented.

  19. HVAC cable systems with forced water cooling for wind energy transmission

    Energy Technology Data Exchange (ETDEWEB)

    Brakelmann, Heinrich; Zhang, Dongping [Duisburg-Essen Univ., Duisburg (DE). Dept. Energy Transport and Storage (ETS)

    2008-07-01

    This paper presents a solution for an efficient wind energy transmission onshore: HVAC cable system with forced water cooling, which provides a substantial increase of the cable ampacity without any modification of the cable construction and design. This work shows the projecting and planning of such HVAC cable systems in combination with a cooling system, especially considering the faulty (n-1)-case. The efficiency utilizing the short-term load capacity of the cable systems transmitting wind energy is shown by computations provided by specialized and adapted FEM (Finite Element Method) software. (orig.)

  20. Organohalogen products from chlorination of cooling water at nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Bean, R.M.

    1983-10-01

    Eight nuclear power units at seven locations in the US were studied to determine the effects of chlorine, added as a biocide, on the composition of cooling water discharge. Water, sediment and biota samples from the sites were analyzed for total organic halogen and for a variety of organohalogen compounds. Haloforms were discharged from all plants studied, at concentrations of a few ..mu..g/L (parts-per-billion). Evidence was obtained that power plants with cooling towers discharge a significant portion of the haloforms formed during chlorination to the atmosphere. A complex mixture of halogenated phenols was found in the cooling water discharges of the power units. Cooling towers can act to concentrate halogenated phenols to levels approaching those of the haloforms. Examination of samples by capillary gas chromatography/mass spectrometry did not result in identification of any significant concentrations of lipophilic base-neutral compounds that could be shown to be formed by the chlorination process. Total concentrations of lipophilic (Bioabsorbable) and volatile organohalogen material discharged ranged from about 2 to 4 ..mu..g/L. Analysis of sediment samples for organohalogen material suggests that certain chlorination products may accumulate in sediments, although no tissue bioaccumulation could be demonstrated from analysis of a limited number of samples. 58 references, 25 figures, 31 tables.

  1. Impact of drought on U.S. steam electric power plant cooling water intakes and related water resource management issues.

    Energy Technology Data Exchange (ETDEWEB)

    Kimmell, T. A.; Veil, J. A.; Environmental Science Division

    2009-04-03

    This report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL) Existing Plants Research Program, which has an energy-water research effort that focuses on water use at power plants. This study complements their overall research effort by evaluating water availability at power plants under drought conditions. While there are a number of competing demands on water uses, particularly during drought conditions, this report focuses solely on impacts to the U.S. steam electric power plant fleet. Included are both fossil-fuel and nuclear power plants. One plant examined also uses biomass as a fuel. The purpose of this project is to estimate the impact on generation capacity of a drop in water level at U.S. steam electric power plants due to climatic or other conditions. While, as indicated above, the temperature of the water can impact decisions to halt or curtail power plant operations, this report specifically examines impacts as a result of a drop in water levels below power plant submerged cooling water intakes. Impacts due to the combined effects of excessive temperatures of the returned cooling water and elevated temperatures of receiving waters (due to high ambient temperatures associated with drought) may be examined in a subsequent study. For this study, the sources of cooling water used by the U.S. steam electric power plant fleet were examined. This effort entailed development of a database of power plants and cooling water intake locations and depths for those plants that use surface water as a source of cooling water. Development of the database and its general characteristics are described in Chapter 2 of this report. Examination of the database gives an indication of how low water levels can drop before cooling water intakes cease to function. Water level drops are evaluated against a number of different power plant characteristics, such as the nature of the water source (river vs. lake or reservoir

  2. Root-zone cooling effect of water-cooled seedling bed on growth of tomato seedling%水冷式苗床根际降温效果及其对番茄幼苗生长的影响

    Institute of Scientific and Technical Information of China (English)

    李胜利; 师晓丹; 夏亚真; 孙治强

    2014-01-01

    the underground water as the natural coolant to lower the root-zone temperature during summer season. The root cooling system consisted of inlet pipe, cooling tube, return pipe and control valve. The profile of cooling tube with a trapezoidal cross section was used, which could increase the contact area between cooling tube and plug trays. Tomato seedlings were grown in 72-cell plug trays that were cooled by cold water flowing through the cooling tube buried at the bottom of plug trays. The objective of this study was to investigate the cooling effect of water-cooled seedling bed and its effect on the growth of tomato seedling. The root zone temperature, growth and physiological characteristics of tomato seedling were analyzed in this study. The results showed that the cumulative temperature, mean daily temperature and mean daily maximum temperature of the root-zone in WSD were on average, 154.1, 4.5 and 6.5℃ lower than those of non-cooled seedling bed (NSD) during tomato seedling period, respectively. The mean temperature diurnal variation of WSD (8.5℃) was milder than that of NSD (13.6℃). The root-zone temperature was analyzed. The results showed that the mean high temperature duration of WSD above 25 and 28℃were 8.0 and 3.1 h per day, respectively. However, the mean high temperature duration of NSD reached 15.6 and 10.3 h. The run length of WSD was shortened by 7.6 and 7.2 h at the fixed level 25 and 28℃, respectively. The leaf evaporating rate of tomato seedling in cooled treatment was enhanced by 36.3%compared with that of non-cooled treatment, which improved the temperature difference between leaf and air. Root activity and the net photosynthetic rate of tomato seedling were also improved significantly. Plant height, dry mass of shoot and root of tomato seedling in cooled treatment were increased by 35.8%and 72.6%compared with seedling of non-cooled treatment, while no significant difference was observed in the stem diameter of seedling between two

  3. Experimental study on the heat transfer characteristics of a nuclear reactor containment wall cooled by gravitationally falling water

    Science.gov (United States)

    Pasek, Ari D.; Umar, Efrison; Suwono, Aryadi; Manalu, Reinhard E. E.

    2012-06-01

    Gravitationally falling water cooling is one of mechanism utilized by a modern nuclear Pressurized Water Reactor (PWR) for its Passive Containment Cooling System (PCCS). Since the cooling is closely related to the safety, water film cooling characteristics of the PCCS should be studied. This paper deals with the experimental study of laminar water film cooling on the containment model wall. The influences of water mass flow rate and wall heat rate on the heat transfer characteristic were studied. This research was started with design and assembly of a containment model equipped with the water cooling system, and calibration of all measurement devices. The containment model is a scaled down model of AP 1000 reactor. Below the containment steam is generated using electrical heaters. The steam heated the containment wall, and then the temperatures of the wall in several positions were measure transiently using thermocouples and data acquisition. The containment was then cooled by falling water sprayed from the top of the containment. The experiments were done for various wall heat rate and cooling water flow rate. The objective of the research is to find the temperature profile along the wall before and after the water cooling applied, prediction of the water film characteristic such as means velocity, thickness and their influence to the heat transfer coefficient. The result of the experiments shows that the wall temperatures significantly drop after being sprayed with water. The thickness of water film increases with increasing water flow rate and remained constant with increasing wall heat rate. The heat transfer coefficient decreases as film mass flow rate increase due to the increases of the film thickness which causes the increasing of the thermal resistance. The heat transfer coefficient increases slightly as the wall heat rate increases. The experimental results were then compared with previous theoretical studied.

  4. Volume and structural analysis of super-cooled water under high pressure

    Science.gov (United States)

    Duki, Solomon F.; Tsige, Mesfin

    2012-02-01

    Motivated by recent experimental study of super-cooled water at high pressure [1], we performed atomistic molecular dynamic simulations study on bulk water molecules at isothermal-isobaric ensemble. These simulations are performed at temperatures that range from 40 K to 380 K using two different cooling rates, 10K/ns and 10K/5ns, and pressure that ranges from 1atm to 10000 atm. Our analysis for the variation of the volume of the bulk sample against temperature indicates a downward concave shape for pressures above certain values, as reported in [1]. The same downward concave behavior is observed at high pressure on the mean-squared-displacements (MSD) of the water molecules when the MSD is plotted against time. To get further insight on the effect of the pressure on the sample we have also performed a structural analysis of the sample.[4pt] [1] O. Mishima, J. Chem. Phys. 133, 144503 (2010);

  5. Ice growth and interface oscillation of water droplets impinged on a cooling surface

    Science.gov (United States)

    Hagiwara, Yoshimichi; Ishikawa, Shoji; Kimura, Ryota; Toyohara, Kazumasa

    2017-06-01

    We focused on the attenuation of air-water interface oscillation for impinged water droplets freezing on a cooling surface. We carried out not only experiments but also two-dimensional numerical simulation on the droplets using a Phase-field method and an immersed boundary method. The Reynolds number and Weber number were in the range of 35-129 and 1.6-22, respectively. The experimental and computational results showed that the height of the impinged droplets on the symmetrical axis started to oscillate as a result of the impact of the collision of droplets with the surfaces in all the cases that we investigated. The measured frequency of the oscillations in the case of the adiabatic droplets was equal to the frequency estimated from the equation for the capillary-gravity waves on sessile droplets (Temperton, 2013) [30]. The oscillations converged rapidly in all impinged water droplets that froze on the cooling surface. This is due partly to the growth of ice shells along the air-water interface and partly to decreases in water volume as a result of the ice growth mainly on the cooling surface. In addition, the thermal field was disturbed not only by the latent heat transfer but also by the upward component of recirculating flow induced by the droplet impingement.

  6. Investigation of Water-spray Cooling of Turbine Blades in a Turbojet Engine

    Science.gov (United States)

    Freche, John C; Stelpflug, William J

    1953-01-01

    An analytical and experimental investigation was made with a J33-A-9 engine to determine the effectiveness of spray cooling as a means of increasing thrust by permitting engine operation at inlet-gas temperatures and speeds above rated. With the assumption of adequate spray cooling at a coolant-to-gas flow ratio of 3 percent, calculations for the sea-level static condition indicated a thrust may be achieved by engine operation at an inlet-gas temperature of 2000 degrees F and an overspeed of 10 percent. Of the water-injection configurations investigated experimentally, those located in the inner ring of the stator diaphragm provided the best cooling at rated engine speed.

  7. A Novel Absorption Cycle for Combined Water Heating, Dehumidification, and Evaporative Cooling

    Energy Technology Data Exchange (ETDEWEB)

    CHUGH, Devesh [University of Florida, Gainesville; Gluesenkamp, Kyle R [ORNL; Abdelaziz, Omar [ORNL; Moghaddam, Saeed [University of Florida, Gainesville

    2014-01-01

    In this study, development of a novel system for combined water heating, dehumidification, and space evaporative cooling is discussed. Ambient water vapor is used as a working fluid in an open system. First, water vapor is absorbed from an air stream into an absorbent solution. The latent heat of absorption is transferred into the process water that cools the absorber. The solution is then regenerated in the desorber, where it is heated by a heating fluid. The water vapor generated in the desorber is condensed and its heat of phase change is transferred to the process water in the condenser. The condensed water can then be used in an evaporative cooling process to cool the dehumidified air exiting the absorber, or it can be drained if primarily dehumidification is desired. Essentially, this open absorption cycle collects space heat and transfers it to process water. This technology is enabled by a membrane-based absorption/desorption process in which the absorbent is constrained by hydrophobic vapor-permeable membranes. Constraining the absorbent film has enabled fabrication of the absorber and desorber in a plate-and-frame configuration. An air stream can flow against the membrane at high speed without entraining the absorbent, which is a challenge in conventional dehumidifiers. Furthermore, the absorption and desorption rates of an absorbent constrained by a membrane are greatly enhanced. Isfahani and Moghaddam (Int. J. Heat Mass Transfer, 2013) demonstrated absorption rates of up to 0.008 kg/m2s in a membrane-based absorber and Isfahani et al. (Int. J. Multiphase Flow, 2013) have reported a desorption rate of 0.01 kg/m2s in a membrane-based desorber. The membrane-based architecture also enables economical small-scale systems, novel cycle configurations, and high efficiencies. The absorber, solution heat exchanger, and desorber are fabricated on a single metal sheet. In addition to the open arrangement and membrane-based architecture, another novel feature of the

  8. Performance of water and diluted ethylene glycol as coolants for electronic cooling

    Directory of Open Access Journals (Sweden)

    M. Gayatri,

    2015-05-01

    Full Text Available As the number of transistors increases with new generation of microprocessor chips, the power draw and heat load to dissipate during operation increases. As a result of increasing the heat loads and heat fluxes the Conventional cooling technologies such as fan, heat sinks are unable to absorb and heat transfer excess heat dissipated by these new microprocessor. So, new technologies are needed to improve the heat removal capacity. In the present work single phase liquid cooling system with mini channel is analyzed and experimentally investigated. Mini channels are chosen as to provide higher heat transfer co-efficient than conventional channel. Copper pipes of 0.36 mm diameter are taken to fabricate heat sink and heat exchanger. A pump is used to circulate the fluid through heat sink and heat exchanger. A solid heated aluminium block to simulate heat generated electronic component is used and electrical input is supplied to the heated aluminium block and cooling system is placed over the heated block. The performance of the cooling system is analyzed from the experimental data obtained. It is experimentally observed that the mini channel liquid cooling system with water as a coolant has better performance than diluted ethylene glycol as coolant at different flow rates. The surface temperature of the heated aluminium block with convective heat transfer co-efficient is observed

  9. Spacesuit Water Membrane Evaporator; An Enhanced Evaporative Cooling Systems for the Advanced Extravehicular Mobility Unit Portable Life Support System

    Science.gov (United States)

    Bue, Grant C.; Makinen, Janice V.; Miller, Sean.; Campbell, Colin; Lynch, Bill; Vogel, Matt; Craft, Jesse; Petty, Brian

    2014-01-01

    Spacesuit Water Membrane Evaporator - Baseline heat rejection technology for the Portable Life Support System of the Advanced EMU center dot Replaces sublimator in the current EMU center dot Contamination insensitive center dot Can work with Lithium Chloride Absorber Radiator in Spacesuit Evaporator Absorber Radiator (SEAR) to reject heat and reuse evaporated water The Spacesuit Water Membrane Evaporator (SWME) is being developed to replace the sublimator for future generation spacesuits. Water in LCVG absorbs body heat while circulating center dot Warm water pumped through SWME center dot SWME evaporates water vapor, while maintaining liquid water - Cools water center dot Cooled water is then recirculated through LCVG. center dot LCVG water lost due to evaporation (cooling) is replaced from feedwater The Independent TCV Manifold reduces design complexity and manufacturing difficulty of the SWME End Cap. center dot The offset motor for the new BPV reduces the volume profile of the SWME by laying the motor flat on the End Cap alongside the TCV.

  10. Effect of diesel leakage in circulating cooling water system on preponderant bacteria diversity and bactericidal effect of biocides.

    Science.gov (United States)

    Zhong, Huiyun; Liu, Fang; Lu, Jinjin; Yang, Wei; Zhao, Chaocheng

    2015-01-01

    Petroleum products leakage results in adverse effect on the normal operation of a circulating cooling water system. However, relatively little research has been done to explore the effect of petroleum products leakage on circulating cooling water quality and biofilm preponderant bacteria diversity. Also, normal biocides application modes cannot fulfil the need for biofilm control. In this study, diesel oil was used as the experimental subject representing leaking petroleum products; the effect of diesel addition on biofilm preponderant bacteria diversity and the bactericidal effect of chlorine dioxide and tetradecyl dimethyl benzyl ammonium chloride (1427) was investigated. Bacterial community structures were examined by PCR-denaturing gradient gel electrophoresis and PCR cloning of 16S rDNA genes. Except for 100 mg/L diesel, increasing diesel concentration enhanced the biofilm detachment ratio compared with the control test. The microstructure of biofilm samples with 0, 300 and 900 mg/L diesel addition was observed. The species of preponderant bacteria in the biofilm sample with 300 mg/L diesel addition were more and the bacterial distribution was more uniform than those in the biofilm sample with 900 mg/L diesel addition. With ClO2 and 1427 addition, chemical oxygen demand increased, lipid phosphorus and bacterial count first decreased and then remained stable, and the bactericidal ratio first increased and then remained stable. Diesel addition variation has more obvious effect on ClO2 than 1427.

  11. HIGH COOLING WATER TEMPERATURE EFFECTS ON DESIGN AND OPERATIONAL SAFETY OF NPPS IN THE GULF REGION

    Directory of Open Access Journals (Sweden)

    BYUNG KOO KIM

    2013-12-01

    Full Text Available The Arabian Gulf region has one of the highest ocean temperatures, reaching above 35 degrees and ambient temperatures over 50 degrees in the summer. Two nuclear power plants (NPP are being introduced in the region for the first time, one at Bushehr (1,000 MWe PWR plant from Russia, and a much larger one at Barakah (4X1,400 MWe PWR from Korea. Both plants take seawater from the Gulf for condenser cooling, having to modify the secondary/tertiary side cooling systems design by increasing the heat transfer surface area from the country of origin. This paper analyses the secondary side of a typical PWR plant operating under the Rankine cycle with a simplified thermal-hydraulic model. Parametric study of ocean cooling temperatures is conducted to estimate thermal efficiency variations and its associated design changes for the secondary side. Operational safety is reviewed to deliver rated power output with acceptable safety margins in line with technical specifications, mainly in the auxiliary systems together with the cooling water temperature. Impact on the Gulf seawater as the ultimate heat sink is considered negligible, affecting only the adjacent water near the NPP site, when compared to the solar radiation on the sea surface.

  12. Economy of replacing a refrigerant in a cooling system for preparing chilled water

    Energy Technology Data Exchange (ETDEWEB)

    Kulcar, B. [Nafta-Petrochem, d.o.o., Mlinska ulica 5, 9220 Lendava (Slovenia); Goricanec, D.; Krope, J. [University of Maribor, Faculty of Chemistry and Chemical Engineering, Smetanova ulica 17, 2000 Maribor (Slovenia)

    2010-08-15

    Due to the negative impact of refrigerants containing Cl and Br on the ozone layer, these refrigerants are being replaced with refrigerants containing fluorine. The article describes the replacing of refrigerant R22 in a cooling system for preparing chilled water, used for cooling reactors producing phenol-formaldehyde resins. After analyzing the existing state and the capabilities of the cooling system, the refrigerant R22 was replaced with refrigerant R407C. For both refrigerants a calculation of the cooling system has been made, the results of which are given in the form of diagrams depending on the evaporation temperature of the refrigerant. Profitability evaluation of replacing a refrigerant was carried out using the method of the net present value (NPV), the coefficient of profitability and the period of time in which the investment is going to return itself. Also the calculations of the savings of electrical energy needed for the running of the compressors and the price of chilled water have been done, using the method of internal profitability level (IPL). (author)

  13. Impact of operating conditions on cooling capacity for sorption systems using water as refrigerant

    Science.gov (United States)

    Tremeac, Brice; Giraud, Florine; Vallon, Pierrick

    2017-02-01

    The implementation of compact heat exchanger in sorption systems is a key factor to allow the development of these systems. The aim of this paper is to develop a statistical model with a design of experiment (DOE) methodology and use dimensionless number to evaluate and understand the influence of the height of refrigerant liquid and secondary fluid inlet temperature on cooling capacity of a compact pate-type evaporator for sorption systems working near vacuum pressure. For this purpose, an experimental campaign was conducted on a small adsorption test bench using 13X/water as working couple. Cooling capacities from 640 to 2000 W were measured. The DOE is a Doelhert type with two parameters: the inlet secondary fluid temperature (from 10 to 21 °C) and the filing level of refrigerant in the evaporator (from 6 to 24 cm). Thanks to the exploitation of the mathematical model obtained, optimal points under different constraints were found. A maximum cooling capacity of 2021 +/-75 W in the entire experimental field was predicted for a secondary fluid inlet temperature of 25°C and a height of liquid level of 19.2 cm. Bond number and modified Jacob number per the ratio Psat/Ptriple were analyzed. The dimensionless numbers are correlated to the cooling capacity as a first step for designing compact plate-type evaporator for adsorption systems using water as refrigerant.

  14. Reuso de efluentes em torres de resfriamento - estudo conceitual: Aeroporto Internacional do Rio de Janeiro = Water reuse for cooling towers – conceptual study: Rio de Janeiro International Airport

    Directory of Open Access Journals (Sweden)

    Denize Dias de Carvalho

    2010-07-01

    Full Text Available O reuso de água é ferramenta valiosa na gestão da água, que promove a otimização da utilização do recurso desta, que reduz e, muitas vezes, até elimina os impactos no meio ambiente. Neste trabalho foi investigada a composição do efluente secundário da estação de tratamento de efluentes (ETE APOIO do Aeroporto Internacional do Rio de Janeiro, com o objetivo de propor o processo adequado à reutilização deste efluente como água de reposição nas torres de resfriamento desse Aeroporto. Com base nas análises de cátions, ânions, DBO e DQO, verificou-se o parâmetro SDT - Cl- como crítico para processamento do efluente. Foi proposta uma sequência para reutilização do efluente que continha o tratamento de osmose inversa, o custo do m3 produzido por essa sequência foi estimado em R$ 2,90 m-3. Water reuse is an important tool in water management; it is a conceptthat promotes optimization of the water resource, reducing and often even eliminating environmental impacts. In this work, the composition of a secondary effluent (from the effluent treatment station (ETE APOIO at Rio de Janeiro International Airport was analyzed, with theaim of determining an adequate process for the reutilization of this effluent as replacement cooling water. Chemical analyses such as cation and anion analysis, BOD and COD were performed. Based on these analyses, it was found that TDS - Cl- was the critical parameter foreffluent processing. A treatment system was proposed for effluent reuse including reverse osmosis; the cost estimate per m3 produced by this system was R$ 2.90 m-3.

  15. Preliminary Analysis on Heat Removal Capacity of Passive Air-Water Combined Cooling Heat Exchanger Using MARS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung-Sin; Jeon, Seong-Su; Hong, Soon-Joon [FNC Tech, Yongin (Korea, Republic of); Bae, Sung-Won; Kwon, Tae-Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Current design requirement for working time of PAFS heat exchanger is about 8 hours. Thus, it is not satisfied with the required cooling capability for the long term SBO(Station Black-Out) situation that is required to over 72 hours cooling. Therefore PAFS is needed to change of design for 72 hours cooling. In order to acquirement of long terms cooling using PAFS, heat exchanger tube has to be submerged in water tank for long time. However, water in the tank is evaporated by transferred heat from heat exchanger tubes, so water level is gradually lowered as time goes on. The heat removal capacity of air cooling heat exchanger is core parameter that is used for decision of applicability on passive air-water combined cooling system using PAFS in long term cooling. In this study, the development of MARS input model and plant accident analysis are performed for the prediction of the heat removal capacity of air cooling heat exchanger. From analysis result, it is known that inflow air velocity is the decisive factor of the heat removal capacity and predicted air velocity is lower than required air velocity. But present heat transfer model and predicted air velocity have uncertainty. So, if changed design of PAFS that has over 4.6 kW heat removal capacity in each tube, this type heat exchanger can be applied to long term cooling of the nuclear power plant.

  16. Molecular Dynamics Simulations of Aqueous and Confined Systems Relevant to the Supercritical Water Cooled Nuclear Reactor

    Science.gov (United States)

    Kallikragas, Dimitrios Theofanis

    Supercritical water (SCW) is the intended heat transfer fluid and potential neutron moderator in the proposed GEN-IV Supercritical Water Cooled Reactor (SCWR). The oxidative environment poses challenges in choosing appropriate design materials, and the behaviour of SCW within crevices of the passivation layer is needed for developing a corrosion control strategy to minimize corrosion. Molecular Dynamics simulations have been employed to obtain diffusion coefficients, coordination number and surface density characteristics, of water and chloride in nanometer-spaced iron hydroxide surfaces. Diffusion models for hydrazine are evaluated along with hydration data. Results demonstrate that water is more likely to accumulate on the surface at low density conditions. The effect of confinement on the water structure diminishes as the gap size increases. The diffusion coefficient of chloride decreases with larger surface spacing. Clustering of water at the surface implies that the SCWR will be most susceptible to pitting corrosion and stress corrosion cracking.

  17. Multi-Model Assessment of Global Hydropower and Cooling Water Discharge Potential Under Climate Change

    Science.gov (United States)

    van Vliet, M. T. H.; van Beek, L. P. H.; Eisener, S.; Wada, Y.; Bierkens, M. F. P.

    2016-01-01

    Worldwide, 98% of total electricity is currently produced by thermoelectric power and hydropower. Climate change is expected to directly impact electricity supply, in terms of both water availability for hydropower generation and cooling water usage for thermoelectric power. Improved understanding of how climate change may impact the availability and temperature of water resources is therefore of major importance. Here we use a multi-model ensemble to show the potential impacts of climate change on global hydropower and cooling water discharge potential. For the first time, combined projections of streamflow and water temperature were produced with three global hydrological models (GHMs) to account for uncertainties in the structure and parametrization of these GHMs in both water availability and water temperature. The GHMs were forced with bias-corrected output of five general circulation models (GCMs) for both the lowest and highest representative concentration pathways (RCP2.6 and RCP8.5). The ensemble projections of streamflow and water temperature were then used to quantify impacts on gross hydropower potential and cooling water discharge capacity of rivers worldwide. We show that global gross hydropower potential is expected to increase between +2.4% (GCM-GHM ensemble mean for RCP 2.6) and +6.3% (RCP 8.5) for the 2080s compared to 1971-2000. The strongest increases in hydropower potential are expected for Central Africa, India, central Asia and the northern high-latitudes, with 18-33% of the world population living in these areas by the 2080s. Global mean cooling water discharge capacity is projected to decrease by 4.5-15% (2080s). The largest reductions are found for the United States, Europe, eastern Asia, and southern parts of South America, Africa and Australia, where strong water temperature increases are projected combined with reductions in mean annual streamflow. These regions are expected to affect 11-14% (for RCP2.6 and the shared socioeconomic

  18. Multi-Model Assessment of Global Hydropower and Cooling Water Discharge Potential Under Climate Change

    Science.gov (United States)

    van Vliet, M. T. H.; van Beek, L. P. H.; Eisener, S.; Wada, Y.; Bierkens, M. F. P.

    2016-01-01

    Worldwide, 98% of total electricity is currently produced by thermoelectric power and hydropower. Climate change is expected to directly impact electricity supply, in terms of both water availability for hydropower generation and cooling water usage for thermoelectric power. Improved understanding of how climate change may impact the availability and temperature of water resources is therefore of major importance. Here we use a multi-model ensemble to show the potential impacts of climate change on global hydropower and cooling water discharge potential. For the first time, combined projections of streamflow and water temperature were produced with three global hydrological models (GHMs) to account for uncertainties in the structure and parametrization of these GHMs in both water availability and water temperature. The GHMs were forced with bias-corrected output of five general circulation models (GCMs) for both the lowest and highest representative concentration pathways (RCP2.6 and RCP8.5). The ensemble projections of streamflow and water temperature were then used to quantify impacts on gross hydropower potential and cooling water discharge capacity of rivers worldwide. We show that global gross hydropower potential is expected to increase between +2.4% (GCM-GHM ensemble mean for RCP 2.6) and +6.3% (RCP 8.5) for the 2080s compared to 1971-2000. The strongest increases in hydropower potential are expected for Central Africa, India, central Asia and the northern high-latitudes, with 18-33% of the world population living in these areas by the 2080s. Global mean cooling water discharge capacity is projected to decrease by 4.5-15% (2080s). The largest reductions are found for the United States, Europe, eastern Asia, and southern parts of South America, Africa and Australia, where strong water temperature increases are projected combined with reductions in mean annual streamflow. These regions are expected to affect 11-14% (for RCP2.6 and the shared socioeconomic

  19. Predicting the residual aluminum level in water treatment process

    OpenAIRE

    J. Tomperi; M. Pelo; K. Leiviskä

    2012-01-01

    In water treatment processes, aluminum salts are widely used as coagulation chemical. High dose of aluminum has been proved to be at least a minor health risk and some evidence points out that aluminum could increase the risk of Alzheimer's disease thus it is important to minimize the amount of residual aluminum in drinking water and water used at food industry. In this study, the data of a water treatment plant (WTP) was analyzed and the residual aluminum in drinking water was predicted usin...

  20. Predicting the residual aluminum level in water treatment process

    OpenAIRE

    J. Tomperi; M. Pelo; K. Leiviskä

    2013-01-01

    In water treatment processes, aluminum salts are widely used as coagulation chemical. High dose of aluminum has been proved to be at least a minor health risk and some evidence points out that aluminum could increase the risk of Alzheimer's disease. Thus it is important to minimize the amount of residual aluminum in drinking water and water used at food industry. In this study, the data of a water treatment plant (WTP) was analyzed and the residual aluminum in drinking water was predicted usi...

  1. Microbiological water purification without the use of chemical disinfection.

    Science.gov (United States)

    Gerba, C P; Naranjo, J E

    2000-01-01

    Point-of-use (POU) water treatment systems are self-contained units that can be used by recreational enthusiasts who normally obtain drinking water from untreated sources (i.e., rivers, lakes, etc). Microbiological water purifier units are capable of removing all waterborne pathogens. The purpose of this study was to evaluate a new technology (Structured Matrix) capable of micro-biologically purifying the water without the use of chemical disinfectants or an external power requirement. Each of 3 identical portable water filtration units were evaluated for their ability to remove Klebsiella terrigena, poliovirus type 1, rotavirus SA-11, and Cryptosporidium parvum oocysts. Units were operated according to the manufacturer's instructions to process 378 L of water. Each unit was challenged with test organisms after 0, 94, 190, 227, 284, 340, and 378 L had passed through it. For the 227-L and 284-L challenges, a "worst-case" water quality (4 degrees C, pH 9, and turbidity 30 NTU) was used that contained 1500 mg/L dissolved solids and 10 mg/L humid acid. At 340-L and 378-L challenges, worst-case water quality was adjusted to pH 5.0. Units were tested after stagnation for 48 hours following passage of 190, 340, and 378 L of water. The geometric average removal exceeded 99.9999% for bacteria, 99.99% for viruses, and 99.9% for Cryptosporidium parvum oocysts. These units comply with the criteria guidelines for microbial removal under the United States Environmental Protection Agency's "Guide Standard and Protocol for Testing Microbiological Water Purifiers."

  2. MODIFIKASI PATI GARUT (Marantha arundinacea DENGAN PERLAKUAN SIKLUS PEMANASAN SUHU TINGGI-PENDINGINAN ( AUTOCLAVING-COOLING CYCLING UNTUK MENGHASILKAN PATI RESISTEN TIPE III [Arrowroot (Marantha arundinacea Starch Modification Through Autoclaving-Cooling Cycling Treatment to Produce Resistant Starch Type III

    Directory of Open Access Journals (Sweden)

    Sugiyono1

    2009-06-01

    Full Text Available The objectives of this research were to modify arrowroot starch to produce resistant starch type III by autoclaving-cooling cycling and to characterize the modified arrowroot starches according to their chemical properties. The research consisted of three steps : arrowroot extraction, starch modification, and chemical characterization. The extraction of arrowroot produced 10.78% starch. Starch modification by autoclaving-cooling cycle(s was run in 6 different treatments with the aim of observing optimal yield of resistant starch. Resistant starch (RS was produced through 1, 3, 5 cycle(s of autoclaving-cooling treatment with different gelatinization periods (15 and 30 minutes autoclaving for each cycle. Properties analyzed were starch digestibility, fat content, protein content, resistant starch content, and dietary fiber content. Native starch and commercial RS type III (Novelose 330 were also analyzed as a comparison. Based on the starch digestibility, modified starch from 5 cycles, 15 minutes gelatinization period had the lowest digestibility while modified starch from 3 cycles, 15 minutes gelatinization period had no significant difference with commercial RS type III. Those two modified starches, native starch, and Novelose 330 were chosen for further chemical analysis. The fat content and protein content of the four samples were below 1% (db. Low fat and protein content were required to optimize the RS yield. The modification treatment increased the dietary fiber content. The RS content of native starch, Novelose 330, modified starch 3 cycles, 15 minutes gelatinization period, and modified starch 5 cycles, 15 minutes gelatinization period were 2.12% (db, 20.80% (db, 10.91% (db, and 12.15% (db, respectively. It means that repeating autoclaving-cooling cycling could increase RS yield up to 6 times.

  3. CHEMICAL VERSUS SERUM TREATMENT OF EPIDEMIC MENINGITIS.

    Science.gov (United States)

    Flexner, S; Amoss, H L

    1916-05-01

    Claims of efficiency have been made at two widely separated periods for the chemical treatment of epidemic meningitis, in the first instance for lysol and in the second for protargol. The use of lysol was long since abandoned; the recommendation for protargol is based on a single series of cases, small in number. Because of the variable severity of epidemics of meningitis, small reliance can be placed on results of treatment limited in extent to small numbers of cases and to one locality. A more uniform and accurate measure of the value of a method of treatment is provided by animals infected experimentally with pathogenic cultures of meningococci. Young guinea pigs respond in a definite manner to intraperitoneal inoculation of virulent meningococci. Neither protargol nor lysol proved to have any curative action on the experimental infection thus produced in these animals. Monkeys respond in a characteristic manner to the inoculation of virulent cultures into the subarachnoid space. Protargol displayed no curative action on the experimental infection thus produced in these animals. On the contrary, both lysol and protargol exert antileukotactic and antiphagocytic effects, and are also potent protoplasmic poisons, and the leukocytes with which they come in contact are injured and made to degenerate. According to the extent to which these harmful properties are exerted, the chemicals promote the advance rather than restrain the progress of meningococcic infection. Recovery from meningococcic infection in man and animals is accomplished chiefly through the process of phagocytosis. The specific antiserum acts curatively by increasing the emigration of leukocytes, by promoting phagocytosis directly, and by agglutinating the meningococci, and also by neutralizing endotoxin. Any means which interfere with and reduce these essential processes retard or prevent recovery. Both lysol and protargol interfere with and diminish the emigration of leukocytes and the phagocytosis

  4. Water cooling of shocks in protostellar outflows: Herschel-PACS map of L1157

    CERN Document Server

    Nisini, B; Codella, C; Giannini, T; Liseau, R; Neufeld, D; Tafalla, M; van Dishoeck, E F; Bachiller, R; Baaudry, A; Benz, O A; Bergin, E; Bjerkeli, P; Blake, G; Bontemps, S; Braine, J; Bruderer, S; Caselli, P; Cernicharo, J; Daniel, F; Encrenaz, P; di Giorgio, A M; Dominik, C; Doty, S; Fich, M; Fuente, A; Goicoechea, J R; de Graaw, Th; Helmich, F; Herczeg, G; Herpin, F; Hogerheijde, M; Jacq, T; Johnstone, D; Jorgensen, J; Kaufman, M; Kirstensen, L; Larsson, B; Lis, D; Marseille, M; McCoey, C; Melnick, G; Olberg, M; Parise, B; Pearson, J; Plime, R; Risacher, C; Santiago, J; Saraceno, P; Shipman, R; van Kempen, T A; Visser, R; Viti, S; Wampfler, S; Wyrowski, F; van der Tak, F; Yildiz, U A; Delforge, B; Desbat, J; Hatch, W A; Peron, I; Schieder, R; Stern, J A; Teyssier, D; Whyborn, N

    2010-01-01

    In the framework of the Water in Star-forming regions with Herschel (WISH) key program, maps in water lines of several outflows from young stars are being obtained, to study the water production in shocks and its role in the outflow cooling. This paper reports the first results of this program, presenting a PACS map of the o-H2O 179 um transition obtained toward the young outflow L1157. The 179 um map is compared with those of other important shock tracers, and with previous single-pointing ISO, SWAS, and Odin water observations of the same source that allow us to constrain the water abundance and total cooling. Strong H2O peaks are localized on both shocked emission knots and the central source position. The H2O 179 um emission is spatially correlated with emission from H2 rotational lines, excited in shocks leading to a significant enhancement of the water abundance. Water emission peaks along the outflow also correlate with peaks of other shock-produced molecular species, such as SiO and NH3. A strong H2O ...

  5. Performance of a silica gel-water adsorption cooling system for use in small-scale tri-generation applications

    Energy Technology Data Exchange (ETDEWEB)

    De Boer, R.; Smeding, S.F.; Grisel, R.J.H. [ECN Energy Efficiency in the Industry, Petten (Netherlands)

    2006-07-15

    The SOCOOL project focuses on the development of a small-scale combined cold, heat and power (tri-generation) system, which utilises the engine waste heat for cold production. It is demonstrated at the CRF Eco-Canteen in Turin, Italy. The cooling machine is made of two separate sub-cooling systems, each of which is to produce 5 kW of cooling power. One of the cooling systems is driven by 'low-temperature' engine cooling water, the other by 'high-temperature' engine exhaust gases. Tri-generation systems that use heat-driven cooling, offer the possibility of saving 15-20% primary energy. The low-temperature-driven sorption-cooling machine was designed and built at ECN, The Netherlands. Its performance was tested in our own laboratories, before shipment to Turin where it was integrated with the internal combustion engine.

  6. Effect of pre-cooling and heat treatment on antioxidant enzymes ...

    African Journals Online (AJOL)

    African Journal of Food, Agriculture, Nutrition and Development ... Increased CAT and POX activities in mango and banana during heat treatment ... Pre-cooling of mango at 8 ºC showed twofold decreased CAT activity in the pulp whereas heat ...

  7. Improved Energy Recovery by Anaerobic Grey Water Sludge Treatment with Black Water

    Directory of Open Access Journals (Sweden)

    Taina Tervahauta

    2014-08-01

    Full Text Available This study presents the potential of combining anaerobic grey water sludge treatment with black water in an up-flow anaerobic sludge blanket (UASB reactor to improve energy recovery within source-separated sanitation concepts. Black water and the mixture of black water and grey water sludge were compared in terms of biochemical methane potential (BMP, UASB reactor performance, chemical oxygen demand (COD mass balance and methanization. Grey water sludge treatment with black water increased the energy recovery by 23% in the UASB reactor compared to black water treatment. The increase in the energy recovery can cover the increased heat demand of the UASB reactor and the electricity demand of the grey water bioflocculation system with a surplus of 0.7 kWh/cap/y electricity and 14 MJ/cap/y heat. However, grey water sludge introduced more heavy metals in the excess sludge of the UASB reactor and might therefore hinder its soil application.

  8. Construction of a cooling water inlet system with settling basin of Derna power plant station (Libya)

    Energy Technology Data Exchange (ETDEWEB)

    Glissmann, R.; Heimburg, A.M. von; Sinner, H.

    1985-03-01

    Construction of a cooling water intake system with settling basin. The extension of the power station at Derna, in Libya, necessitated the construction of a new cooling water intake system including screening facilities and a settling basin. Construction based on extensive prefabrication (precast concrete) was chosen. The precast reinforced units, ranging up to about 4000 t in weight, were towed on barges to the site of erection. At Derna these units were temporarily stored on the sea bed for several months, during which they were exposed to winter storms and rough sea. The major precast portion of the settling basin was constructed direct on the barge. On arrival at the site, the barge was sunk, allowing the precast unit, which was designed with sufficient buoyancy, to be floated off. The open unprotected coast required special arrangements for the protection of personnel, structures and equipment.

  9. Tritium recovery in Pb17Li-water cooled blanket systems

    Energy Technology Data Exchange (ETDEWEB)

    Malara, C. [Safety Technology Inst., Ispra (Italy); Casini, G. [Systems Engineering & Information Inst., Ispra (Italy); Viola, A. [Univ. of Cagliari (Italy)

    1994-12-31

    The question of tritium recovery in Pb17Li, water cooled blankets is under investigation since several years at JRC Ispra. The method which has been more extensively analyzed is that of slowly circulating the breeder out from the blanket units and of extracting the tritium from it outside the plasma vacuum vessel by helium gas purging in a suited process apparatus. The design features of the process systems are related to: (1) the very low tritium solubility in Pb17Li which implies high permeation rates through the containment structures; (2) the need of keeping as low as possible the tritium concentration in the cooling water both for safety and economical reasons. A computerized model of the tritium behavior in the blanket units and in the extraction system has been developed.

  10. Neutronics Analysis of Water-Cooled Ceramic Breeder Blanket for CFETR

    Science.gov (United States)

    Zhu, Qingjun; Li, Jia; Liu, Songlin

    2016-07-01

    In order to investigate the nuclear response to the water-cooled ceramic breeder blanket models for CFETR, a detailed 3D neutronics model with 22.5° torus sector was developed based on the integrated geometry of CFETR, including heterogeneous WCCB blanket models, shield, divertor, vacuum vessel, toroidal and poloidal magnets, and ports. Using the Monte Carlo N-Particle Transport Code MCNP5 and IAEA Fusion Evaluated Nuclear Data Library FENDL2.1, the neutronics analyses were performed. The neutron wall loading, tritium breeding ratio, the nuclear heating, neutron-induced atomic displacement damage, and gas production were determined. The results indicate that the global TBR of no less than 1.2 will be a big challenge for the water-cooled ceramic breeder blanket for CFETR. supported by the National Magnetic Confinement Fusion Science Program of China (Nos. 2013GB108004, 2014GB122000, and 2014GB119000), and National Natural Science Foundation of China (No. 11175207)

  11. High power testing of water-cooled waveguide for ITER-like ECH transmission lines

    Science.gov (United States)

    Anderson, J. P.; Doane, J. L.; Grunloh, H. J.; O'Neill, R. C.; Ikeda, R.; Oda, Y.; Takahashi, K.; Sakamoto, K.

    2017-05-01

    The results of high power testing of new water-cooled ECH waveguide components for ITER are presented. The components are a precision-coupled 4.2 m waveguide assembly, a short expansion joint, and water-cooled waveguide for gyrotron commissioning. The testing was conducted at the QST Naka Fusion Institute using gyrotron pulses of 450 kW at 170 GHz for 300 s. Analysis shows that the power absorbed per unit length for the various waveguide components are dependent on location in the transmission line with respect to high order mode generators, such as miter bends. Additionally, larger-than-expected reflections from the load led to high absorption levels in the transmission line.

  12. Fishing for isotopes in the Brookhaven Lab Isotope Producer (BLIP) cooling water

    Energy Technology Data Exchange (ETDEWEB)

    Fitzsimmons, Jonathan [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider Accelerator Dept.

    2016-04-29

    Be-7 has been used in environmental studies; the isotope is produced during BLIP irradiations and accumulates in the 320 gallons of cooling water. Be-7 has a 53.24 day half-life, so the optimal production/purification time is at the end of the BLIP run season. To purify Be-7 fifteen to twenty gallons of BLIP cooling water are removed and pumped through ion exchange columns that retain Be-7. This labor intensive approach captures ~15 mCi of Be-7, but the solution requires further purification. The method can lead to increased radiation exposure to staff. The ideal way to capture isotopes from large volumes is to reach in to the solution and selectively pull out the desired isotope. It is a lot like fishing.

  13. Prospects for development of an innovative water-cooled nuclear reactor for supercritical parameters of coolant

    Science.gov (United States)

    Kalyakin, S. G.; Kirillov, P. L.; Baranaev, Yu. D.; Glebov, A. P.; Bogoslovskaya, G. P.; Nikitenko, M. P.; Makhin, V. M.; Churkin, A. N.

    2014-08-01

    The state of nuclear power engineering as of February 1, 2014 and the accomplished elaborations of a supercritical-pressure water-cooled reactor are briefly reviewed, and the prospects of this new project are discussed based on this review. The new project rests on the experience gained from the development and operation of stationary water-cooled reactor plants, including VVERs, PWRs, BWRs, and RBMKs (their combined service life totals more than 15 000 reactor-years), and long-term experience gained around the world with operation of thermal power plants the turbines of which are driven by steam with supercritical and ultrasupercritical parameters. The advantages of such reactor are pointed out together with the scientific-technical problems that need to be solved during further development of such installations. The knowledge gained for the last decade makes it possible to refine the concept and to commence the work on designing an experimental small-capacity reactor.

  14. Onsite Waste Water Treatment System

    Directory of Open Access Journals (Sweden)

    T. Subramani

    2014-06-01

    Full Text Available Onsite wastewater treatment systems (OWTSs have evolved from the pit privies used widely throughout history to installations capable of producing a disinfected effluent that is fit for human consumption. Although achieving such a level of effluent quality is seldom necessary, the ability of onsite systems to remove settles able solids, floatable grease and scum, nutrients, and pathogens. From wastewater discharges defines their importance in protecting human health and environmental resources. In the modern era, the typical onsite system has consisted primarily of a septic tank and a soil absorption field, also known as a subsurface wastewater infiltration system, or SWIS. In this manual, such systems are referred to as conventional systems. Septic tanks remove most settle able and floatable material and function as an anaerobic bioreactor that promotes partial digestion of retained organic matter. Septic tank effluent, which contains significant concentrations of pathogens and nutrients, has traditionally been discharged to soil, sand, or other media absorption fields (SWISs for further treatment through biological processes, adsorption, filtration, and infiltration into underlying soils. Conventional systems work well if they are installed in areas with appropriate soils and hydraulic capacities; designed to treat the incoming waste load to meet public health, ground water, and surface water performance standards; installed properly; and maintained to ensure long-term performance. These criteria, however, are often not met. Only about one-third of the land area in the United States has soils suited for conventional subsurface soil absorption fields. System densities in some areas exceed the capacity of even suitable soils to assimilate wastewater flows and retain and transform their contaminants. In addition, many systems are located too close to ground water or surface waters and others, particularly in rural areas with newly installed public

  15. Natural Convective Heat and Mass Transfer of Water with Corrosion Products at Super—Critical Pressures under Cooling COnditions

    Institute of Scientific and Technical Information of China (English)

    Pei-XueJiang; Ze-PeiRen; 等

    1993-01-01

    A numerical study is reported of laminar natural convective heat and mass transfer on a vertical cooled plate for water containing metal corrosion products at super-critical pressures.The influence of variable properties at super-critical pressures on natural convertion has been analyzed.The difference between heat and mass transfer under cooling or heating conditions is also discussed and some correlations for heat and mass transfer under cooling conditions are recommended.

  16. The unexpected energy saving of cooling water conditioning; Koelwaterconditionering spaart meer energie dan u denkt

    Energy Technology Data Exchange (ETDEWEB)

    Dijkgraaf, A. [ed.

    1996-09-01

    On the basis of the example of the dosage of chlorinated bleaching lye in cooling water it is calculated that much more energy can be saved than expected. The use of the lye improves the energy efficiency of heat exchangers. The calculation method is developed by L. Paping and is based on the idea to express the advantages (e.g. energy conservation) and the disadvantages (e.g. environmental burden) as a dimensionless indicator.

  17. Topical report : NSTF facilities plan for water-cooled VHTR RCCS : normal operational tests.

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, M. T.; Kilsdonk, D. J.; Tzanos, C. P.; Lomperski, S.; Aeschlimann, R. W.; Nuclear Engineering Division

    2006-09-01

    As part of the Department of Energy (DOE) Generation IV roadmapping activity, the gas-cooled Very High Temperature Reactor (VHTR) has been selected as the principal concept for hydrogen production and other process-heat applications such as district heating and potable water production. On this basis, the DOE has selected the VHTR for additional R&D with the ultimate goal of demonstrating emission-free electricity and hydrogen production with this advanced reactor concept.

  18. Water-Cooled Data Center Packs More Power Per Rack | Poster

    Science.gov (United States)

    By Frank Blanchard and Ken Michaels, Staff Writers Behind each tall, black computer rack in the data center at the Advanced Technology Research Facility (ATRF) is something both strangely familiar and oddly out of place: It looks like a radiator. The back door of each cabinet is gridded with the coils of the Liebert cooling system, which circulates chilled water to remove heat generated by the high-speed, high-capacity, fault-tolerant equipment.

  19. Thermal-hydraulic Optimization of Water-cooled Center Conductor Post for Spherical Tokamaks Reactor

    Institute of Scientific and Technical Information of China (English)

    柯严; 吴宜灿; 黄群英; 郑善良

    2002-01-01

    This paper proposes a conceptual structure of segmental water-cooled Center Con ductor Post (CCP) to be flexible in installment and replacement. Thermal-hydraulic optimization and sensitivity analysis of key parameters are performed based on a reference fusion transmutation system with 100 MW fusion power. Numerical simulation by using a commercial code PHOEN]CS has been carried out to be close to the thermal-hydraulic analytical results of the CCP mid-part.

  20. Analysis of tritium behaviour and recovery from a water-cooled Pb17Li blanket

    Energy Technology Data Exchange (ETDEWEB)

    Malara, C. [Institute Regional des Materiaux Avances, Ispra (Italy); Casini, G. [Systems Engineering and Informatics Institute, JRC Ispra, Ispra (Vatican City State, Holy See) (Italy); Viola, A. [Department of Chemical Engineering, University of Cagliari, Cagliari (Italy)

    1995-03-01

    The question of the tritium recovery in water-cooled Pb17Li blankets has been under investigation for several years at JRC Ispra. The method which has been more extensively analysed is that of slowly circulating the breeder out from the blanket units and of extracting the tritium from it outside the plasma vacuum vessel by helium gas purging or vacuum degassing in a suited process apparatus. A computerized model of the tritium behaviour in the blanket units and in the extraction system was developed. It includes four submodels: (1) tritium permeation process from the breeder to the cooling water as a function of the local operative conditions (tritium concentration in Pb17Li, breeder temperature and flow rate); (2) tritium mass balance in each breeding unit; (3) tritium desorption from the breeder material to the gas phase of the extraction system; (4) tritium extraction efficiency as a function of the design parameters of the recovery apparatus. In the present paper, on the basis of this model, a parametric study of the tritium permeation rate in the cooling water and of the tritium inventory in the blanket is carried out. Results are reported and discussed in terms of dimensionless groups which describe the relative effects of the overall resistance on tritium transfer to the cooling water (with and without permeation barriers), circulating Pb17Li flow rate and extraction efficiency of the tritium recovery unit. The parametric study is extended to the recovery unit in the case of tritium extraction by helium purge or vacuum degassing in a droplet spray unit. (orig.).

  1. Water-Cooled Data Center Packs More Power Per Rack | Poster

    Science.gov (United States)

    By Frank Blanchard and Ken Michaels, Staff Writers Behind each tall, black computer rack in the data center at the Advanced Technology Research Facility (ATRF) is something both strangely familiar and oddly out of place: It looks like a radiator. The back door of each cabinet is gridded with the coils of the Liebert cooling system, which circulates chilled water to remove heat generated by the high-speed, high-capacity, fault-tolerant equipment.

  2. Introduction to Chemistry for Water and Wastewater Treatment Plant Operators. Water and Wastewater Training Program.

    Science.gov (United States)

    South Dakota Dept. of Environmental Protection, Pierre.

    Presented are basic concepts of chemistry necessary for operators who manage drinking water treatment plants and wastewater facilities. It includes discussions of chemical terms and concepts, laboratory procedures for basic analyses of interest to operators, and discussions of appropriate chemical calculations. Exercises are included and answer…

  3. Microbiological and chemical assessment of spring water from a ...

    African Journals Online (AJOL)

    GREG

    2013-06-20

    Jun 20, 2013 ... 1Environmental Microbiology and Biotechnology Unit, Department of Microbiology, ... Physico-chemical properties of the spring waters were mostly within ..... Standard methods for Examination of water and wastewater.

  4. Effect of thermal, chemical and thermo-chemical pre-treatments to enhance methane production

    DEFF Research Database (Denmark)

    Rafique, Rashad; Poulsen, Tjalfe; Nizami, Abdul-Sattar

    2010-01-01

    -treatments: thermal, thermo-chemical and chemical pre-treatments on the biogas and methane potential of dewatered pig manure. A laboratory scale batch digester is used for these pre-treatments at different temperature range (25 degrees C-150 degrees C). Results showed that thermo-chemical pretreatment has high effect...

  5. Effects of Solution Hydrodynamics on Corrosion Inhibition of Steel by Citric Acid in Cooling Water

    Science.gov (United States)

    Ashassi-Sorkhabi, H.; Asghari, E.; Mohammadi, M.

    2014-08-01

    Corrosion is a major problem in cooling water systems, which is often controlled using corrosion inhibitors. Solution hydrodynamics is one of the factors affecting corrosion inhibition of metals in these systems. The present work focuses on the study of the combined effects of citric acid concentration (as a green corrosion inhibitor) and fluid flow on corrosion of steel in simulated cooling water. Electrochemical techniques including Tafel polarization and electrochemical impedance spectroscopy were used for corrosion studies. Laminar flow was simulated using a rotating disk electrode. The effects of solution hydrodynamics on inhibition performance of citric acid were discussed. The citric acid showed low inhibition performance in quiescent solution; however, when the electrode rotated at 200 rpm, inhibition efficiency increased remarkably. It was attributed mainly to the acceleration of inhibitor mass transport toward metal surface. The efficiencies were then decreased at higher rotation speeds due to enhanced wall shear stresses on metal surface and separation of adsorbed inhibitor molecules. This article is first part of authors' attempts in designing green inhibitor formulations for industrial cooling water. Citric acid showed acceptable corrosion inhibition in low rotation rates; thus, it can be used as a green additive to the corrosion inhibitor formulations.

  6. Development of a brazing process for the production of water- cooled bipolar plates made of chromium-coated metal foils for PEM fuel cells

    Science.gov (United States)

    Mueller, M.; Hoehlich, D.; Scharf, I.; Lampke, T.; Hollaender, U.; Maier, H. J.

    2016-03-01

    Beside lithium batteries, PEM fuel cells are the most promising strategy as a power source to achieve the targets for introducing and increasing the usage of electric vehicles. Due to limited space and weight problems, water cooled, metallic bipolar plates in a fuel cell metal stack are preferred in motor vehicles. These plates are stamped metal sheets with a complex structure, interconnected media-tight. To meet the multiple tasks and requirements in use, complex and expensive combinations of materials are currently in use (carbon fiber composites, graphite, gold-plated nickel, stainless and acid resistant steel). The production of such plates is expensive as it is connected with considerable effort or the usage of precious metals. As an alternative, metalloid nitrides (CrN, VN, W2N, etc.) show a high chemical resistance, hardness and a good conductivity. So this material category meets the basic requirements of a top layer. However, the standard methods for their production (PVD, CVD) are expensive and have a slow deposition rate and a lower layer thicknesses. Because of these limitations, a full functionality over the life cycle of a bipolar plate is not guaranteed. The contribution shows the development and quantification of an alternative production process for bipolar plates. The expectation is to get significant advantages from the combination of chromium electrodeposition and thermochemical treatment to form chromium nitrides. Both processes are well researched and suitable for series production. The thermochemical treatment of the chromium layer also enables a process-integrated brazing.

  7. Experimental adsorption equilibrium study and comparison of zeolite with water and ethanol for cooling systems

    Institute of Scientific and Technical Information of China (English)

    MAIGA Abdoulaye Siddeye; CHEN Guang-ming; WANG Qin

    2007-01-01

    Two adsorption refrigeration working pairs of zeolite with water and ethanol were studied and the parameters of Dubinin-Astakhov model were regressed using the experimental data of equilibrium. The coefficient of heterogeneity varied from 1.305 to 1.52 for the zeolite-water pair and from 1.73 to 2.128 for zeolite-ethanol pair. The maximum adsorption capacity varied from 0.315 to 0.34 for zeolite-water and 0.23 to 0.28 for zeolite-ethanol, respectively. The results showed that the zeolite-water pair is suitable for solar energy cooling not only because of the high latent heat of vaporization of water but also because of the better equilibrium performance. On the other hand, zeolite-ethanol gives a high adsorption capacity at high regeneration temperature, which means it can be used in heat engine systems like buses and cars.

  8. Antimicrobial commodities. 7. Biocide for water treatment; Kokin seikatsu yohin. 7. Suraimu control zai no kokin bo kabi sayo

    Energy Technology Data Exchange (ETDEWEB)

    Sugi, T. [Kurita Water Industries Ltd., Tokyo (Japan)

    1998-10-01

    Outlined in this report are microbe-caused troubles that happen in manufacturing processes particularly in water treatment systems, measures for dealing with such troubles, and the antimicrobial and fungicidal functions presented by slime inhibiting agents. In heat exchangers in production lines in chemical and iron-making industries, and in paper making processes in paper and pulp industry, deposits, called slime and composed mainly of microbes, occur to cause various troubles such as reduction in production efficiency. In general, vermicides and multiplication depressants are used for the prevention and removal of slime deposition. They include chlorine gas, sodium hypochlorite, chlorinated isocyanuric acid, and dibromohydantoin, which are used for slime control mainly in cooling water systems. Slime inhibitors are needed for paper pulp, antiseptic agents with its effect lasting long are required for industrial production, and, in small cooling towers where chlorine management is demanding, antimicrobial agents of the organic nature are used. In case water treatment is inappropriately performed, troubles may be caused by Legionella microbes, for whose destruction chemical-aided washing is necessary. (NEDO)

  9. Heat transfer coefficient distribution over the inconel plate cooled from high temperature by the array of water jets

    Science.gov (United States)

    Malinowski, Z.; Telejko, T.; Cebo-Rudnicka, A.; Szajding, A.; Rywotycki, M.; Hadała, B.

    2016-09-01

    The industrial rolling mills are equipped with systems for controlled water cooling of hot steel products. A cooling rate affects the final mechanical properties of steel which are strongly dependent on microstructure evolution processes. In case of water jets cooling the heat transfer boundary condition can be defined by the heat transfer coefficient. In the present study one and three dimensional heat conduction models have been employed in the inverse solution to heat transfer coefficient. The inconel plate has been heated to about 900oC and then cooled by one, two and six water jets. The plate temperature has been measured by 30 thermocouples. The heat transfer coefficient distributions at plate surface have been determined in time of cooling.

  10. Thermal and structural finite element analysis of water cooled silicon monochromator for synchrotron radiation comparison of two different cooling schemes

    CERN Document Server

    Artemiev, A I; Busetto, E; Hrdy, J; Mrazek, D; Plesek, I; Savoia, A

    2001-01-01

    The article describes the results of Finite Element Analysis (FEA) of the first Si monochromator crystal distortions due to Synchrotron Radiation (SR) heat load and consequent analysis of the influence of the distortions on a double crystal monochromator performance. Efficiencies of two different cooling schemes are compared. A thin plate of Si crystal is lying on copper cooling support in both cases. There are microchannels inside the cooling support. In the first model the direction of the microchannels is parallel to the diffraction plane. In the second model the direction of the microchannels is perpendicular to the diffraction plane or in other words, it is a conventional cooling scheme. It is shown that the temperature field along the crystal volume is more uniform and more symmetrical in the first model than in the second (conventional) one.

  11. Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corporation, Columbus, Ohio

    Science.gov (United States)

    1980-01-01

    The solar energy system installed in the building has 2,978 sq ft of single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/hour water tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.

  12. Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corp. , Columbus, Ohio. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-11-01

    The Solar Energy System located at the Columbia Gas Corporation, Columbus, Ohio, has 2978 ft/sup 2/ of Honeywell single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/h Bryan water-tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton Arkla hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts are included from the site files, specification references, drawings, installation, operation and maintenance instructions.

  13. Analysis of power and cooling cogeneration using ammonia-water mixture

    Energy Technology Data Exchange (ETDEWEB)

    Padilla, Ricardo Vasquez [Clean Energy Research Center, University of South Florida, 4202 E. Fowler Av. ENB 118 Tampa, Fl 33620 (United States); Department of Mechanical Engineering, Universidad del Norte, Barranquilla (Colombia); Demirkaya, Goekmen; Goswami, D. Yogi; Stefanakos, Elias; Rahman, Muhammad M. [Clean Energy Research Center, University of South Florida, 4202 E. Fowler Av. ENB 118 Tampa, Fl 33620 (United States)

    2010-12-15

    Development of innovative thermodynamic cycles is important for the efficient utilization of low-temperature heat sources such as solar, geothermal and waste heat sources. This paper presents a parametric analysis of a combined power/cooling cycle, which combines the Rankine and absorption refrigeration cycles, uses ammonia-water mixture as the working fluid and produces power and cooling simultaneously. This cycle, also known as the Goswami Cycle, can be used as a bottoming cycle using waste heat from a conventional power cycle or as an independent cycle using solar or geothermal energy. A thermodynamic study of power and cooling cogeneration is presented. The performance of the cycle for a range of boiler pressures, ammonia concentrations and isentropic turbine efficiencies are studied to find out the sensitivities of net work, amount of cooling and effective efficiencies. The roles of rectifier and superheater on the cycle performance are investigated. The cycle heat source temperature is varied between 90-170 C and the maximum effective first law and exergy efficiencies for an absorber temperature of 30 C are calculated as 20% and 72%, respectively. The turbine exit quality of the cycle for different boiler exit scenarios shows that turbine exit quality decreases when the absorber temperature decreases. (author)

  14. Performance Analysis of Photovoltaic Panels with Earth Water Heat Exchanger Cooling

    Directory of Open Access Journals (Sweden)

    Jakhar Sanjeev

    2016-01-01

    Full Text Available The operating temperature is an important factor affecting the performance and life span of the Photovoltaic (PV panels. The rising temperature can be maintained within certain limit using proper cooling techniques. In the present research a novel system for cooling of PV panels named as Earth Water Heat Exchanger (EWHE is proposed and modelled in transient analysis simulation tool (TRNSYS v17.0 for the conditions of Pilani, Rajasthan (India.The various parameters which include cell temperature, PV power output and cell efficiency are observed with respect to variation in mass flow rate of fluid. Simulation results of the system without cooling show that the maximum PV panel temperature reached up to 79.31 °C with electrical efficiency dropped to 9% during peak sunshine hour. On the other hand, when PV panels are coupled with EWHE system, the panel temperature drops to 46.29 °C with an efficiency improving to 11% for a mass flow rate of 0.022 kg/s. In the end the cooling potential of EWHE is found to be in direct correlation with mass flow rate. The proposed system is very useful for the arid regions of western India which are blessed with high solar insolation throughout the year.

  15. Electrochemical Treatment of Water Contaminated with Methylorange

    Directory of Open Access Journals (Sweden)

    Valica Martin

    2016-06-01

    Full Text Available This study examines electrochemical degradation of water artificially contaminated by azo dye Methyl Orange (MO. Degradation is based on chemical electro-oxidation of MO molecules. Graphite was used as an electrode material for electrochemical oxidation of MO. In this work, the different operative parameters (electric current, NaCl content and their effect on effectiveness as well as the treatment time/duration of MO degradation were tested. The highest dye removal (91.0 % was obtained during the electrolysis at current density 3.032 mA/cm2, electrolyte with the content of NaCl 4 g/dm3 (NaCl and the treatment time 35 min.

  16. An opacity-sampled treatment of water vapor

    Science.gov (United States)

    Alexander, David R.; Augason, Gordon C.; Johnson, Hollis R.

    1989-01-01

    Although the bands of H2O are strong in the spectra of cool stars and calculations have repeatedly demonstrated their significance as opacity sources, only approximate opacities are currently available, due both to the difficulty of accounting for the millions of lines involved and to the inadequacy of laboratory and theoretical data. To overcome these obstacles, a new treatment is presented, based upon a statistical representation of the water vapor spectrum derived from available laboratory data. This statistical spectrum of water vapor employs an exponential distribution of line strengths and random positions of lines whose overall properties are forced to reproduce the mean opacities observed in the laboratory. The resultant data set is then treated by the opacity-sampling method exactly as are all other lines, both molecular and atomic. Significant differences are found between the results of this improved treatment and the results obtained with previous treatments of water-vapor opacity.

  17. Temperature distribution of a hot water storage tank in a simulated solar heating and cooling system

    Science.gov (United States)

    Namkoong, D.

    1976-01-01

    A 2,300-liter hot water storage tank was studied under conditions simulating a solar heating and cooling system. The initial condition of the tank, ranging from 37 C at the bottom to 94 C at the top, represented a condition midway through the start-up period of the system. During the five-day test period, the water in the tank gradually rose in temperature but in a manner that diminished its temperature stratification. Stratification was found not to be an important factor in the operation of the particular solar system studied.

  18. Effect of Magnetic Treatment of Water on Evapotranspiration of Tomato

    Directory of Open Access Journals (Sweden)

    K. O. Yusuf

    2017-02-01

    Full Text Available This study was conducted to determine the effect of magnetic treatment of water on the evapotranspiration of tomato plant. Evapotranspiration is important to plant for metabolic processes and it also cools the plant. Three magnetic flux densities of 124, 319 and 719 G produced from electromagnet (the treatments labelled as T1, T2 and T3 were used to treat the water and a control experiment (TC was also set up which was irrigated with non-magnetic treatment water. Equal amount of water was applied to all the tomato plant (variety UC82B at the same time. Each treatment was replicated seven times given a total of 28 buckets containing tomato plant. The tomato was planted in the 28 buckets in a transparent garden shed for 130 days (23/09/2014 – 30/01/2015. A complete randomized design (CRD experimental layout was used. The amount of water lost due to evapotranspiration per day was determined by weight lost in the bucket (lysimetric weighing method. The mean values of daily evapotranspiration for two stands of tomato plants per bucket over a period of 65 days for T1, T2, T3 and TC were 9.38, 9.28, 9.18 and 8.03 mm/day respectively. The result of the evapotranspiration due to mass of water lost from the buckets containing tomato plants irrigated with magnetic water were all higher than the values of evapotranspiration from non-magnetic water. This indicated that tomato plant irrigated with magnetic treatment of water absorbed more water from the soil easily and grew faster than the tomato plant irrigated with non-magnetic treatment water with the same quantity of water applied to the tomato plant.

  19. Water treatment processes for oilfield steam injection

    Energy Technology Data Exchange (ETDEWEB)

    Shannon, A.; Pauley, J.C. [Chevron Canada Ltd., Vancouver, BC (Canada)

    2009-07-01

    Various water treatment processes are used within the oilfield industry. Processes tend to be common within one region of the world, but different between regions due to untreated water characteristics and treated water quality requirements. This paper summarized Chevron's view of water treatment requirements and processes for oilfield steam injection. It identified water treatment systems that have been used at thermal projects, where they are most commonly utilized, their purpose, and the limits of each process. The advantages and disadvantages of different water treatment systems were also reviewed. The paper focused on the treatment of fresh waters, low-TDS produced waters, high-hardness waters, and high-silica produced waters. Challenges and opportunities were also identified. It was concluded that the challenges created by high-silica, or by high-hardness produced waters lead to more costly processes. 25 refs., 5 tabs., 4 figs.

  20. Chitosan on Reducing Chemical Oxygen Demands in Laundry Waste Water

    Directory of Open Access Journals (Sweden)

    Tri Joko

    2016-09-01

    Full Text Available Laundry liquid waste contains several chemical substances in detergent raw materials such as phosphate, surfactants, ammonia, and total suspended solids. The existence of detergent in high concentrations and exceeds the quality standards that have been estabilished in a body of water can lead to cases of enviromental pollution in the form of increased turbidity an Chemical Oxygen Demands (COD levels. Therefore in order to maintain and to ensure the availabillity of water in terms of quality, it requires coagulation-flocculation process to laundry liquid waste before discharging into water bodies. This study aims to determine the decrease of COD levels and turbidity level in laundry liquid waste using chitosan coagulant in “X” laundry, Tembalang District, Semarang. The research is a quasi experimental study with pretest-posttest with control group research design with 6 times replication. The total samples are 60 in wich 24 tested for the levels of turbidity and 6 controls. The test results of Kruskal-Wallis with significance p-value < 0,05 indicates that dosage variation (p=0,000 gives different levels of COD and dosage variation (p=0,000 provide 755,97 mg/l and the advantage levels of turbidity before treatment was 516,20 NTU. The optimum dosage of chitosan coagulant is on the dose of 200 mg/l with the effectiveness decrease of COD levels and turbidity levels on 72,67% an 98,67% respectively.

  1. Fundamental aspects of oily waters treatment from the mineral industries by electrolytic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Merma, A.G.; Gonzales, L.V.; Torem, M.L. [Pontifical Catholic Univ. of Rio de Janeiro, Rio de Janeiro (Brazil). Dept. of Materials Engineering

    2010-07-01

    There is an immediate need to develop innovative and more effective techniques for treatment of wastewaters as regulations on effluent wastewater discharge are becoming increasingly prevalent. The mining and metallurgical industries generate wastewaters that contain stable oil-in-water emulsions, arising from residues of liquid streams that serve the purpose of lubrication, cooling, cleaning and corrosion prevention in the equipment used in those industries. Chemically stabilized oil-water emulsions produced in the mineral industries can be treated using an electrocoagulation technique that considers the effects of operating parameters such as initial pH, current density, reaction time, electrode area/liquid volume ratio and electrode materials on the separation of oil as measured by the chemical oxygen demand. The paper discussed electrocoagulation as well as the materials and methods for the study, including oil in water emulsions; the experimental apparatus; and the experimental procedure. It was concluded that the electrolysis of this kind of oil in water emulsions with aluminum electrodes resulted in pH neutralization regardless of the initial pH tested. 18 refs., 4 figs.

  2. Water quality index calculated from biological, physical and chemical attributes.

    Science.gov (United States)

    Rocha, Francisco Cleiton; Andrade, Eunice Maia; Lopes, Fernando Bezerra

    2015-01-01

    To ensure a safe drinking water supply, it is necessary to protect water quality. To classify the suitability of the Orós Reservoir (Northeast of Brazil) water for human consumption, a Water Quality Index (WQI) was enhanced and refined through a Principal Component Analysis (PCA). Samples were collected bi-monthly at seven points (P1 - P7) from July 2009 to July 2011. Samples were analysed for 29 physico-chemical attributes and 4 macroinvertebrate metrics associated with the macrophytes Pistia stratiotes and Eichhornia crassipes. PCA allowed us to reduce the number of attributes from 33 to 12, and 85.32% of the variance was explained in five dimensions (C1 - C5). Components C1 and C3 were related to water-soluble salts and reflect the weathering process, while C2 was related to surface runoff. C4 was associated with macroinvertebrate diversity, represented by ten pollution-resistant families. C5 was related to the nutrient phosphorus, an indicator of the degree of eutrophication. The mean values for the WQIs ranged from 49 to 65 (rated as fair), indicating that water can be used for human consumption after treatment. The lowest values for the WQI were recorded at the entry points to the reservoir (P3, P1, P5, and P4), while the best WQIs were recorded at the exit points (P6 and P7), highlighting the reservoir's purification ability. The proposed WQI adequately expressed water quality, and can be used for monitoring surface water quality.

  3. Technical analysis of a river basin-based model of advanced power plant cooling technologies for mitigating water management challenges

    Energy Technology Data Exchange (ETDEWEB)

    Stillwell, Ashlynn S [Department of Civil, Architectural, and Environmental Engineering, University of Texas at Austin, 1 University Station C1786, Austin, TX 78712 (United States); Clayton, Mary E; Webber, Michael E, E-mail: ashlynn.stillwell@mail.utexas.edu, E-mail: mclayton34@mail.utexas.edu, E-mail: webber@mail.utexas.edu [Department of Mechanical Engineering, University of Texas at Austin, 1 University Station C2200, Austin, TX 78712 (United States)

    2011-07-15

    Thermoelectric power plants require large volumes of water for cooling, which can introduce drought vulnerability and compete with other water needs. Alternative cooling technologies, such as cooling towers and hybrid wet-dry or dry cooling, present opportunities to reduce water diversions. This case study uses a custom, geographically resolved river basin-based model for eleven river basins in the state of Texas (the Brazos and San Jacinto-Brazos, Colorado and Colorado-Brazos, Cypress, Neches, Nueces, Red, Sabine, San Jacinto, and Trinity River basins), focusing on the Brazos River basin, to analyze water availability during drought. We utilized two existing water availability models for our analysis: (1) the full execution of water rights-a scenario where each water rights holder diverts the full permitted volume with zero return flow, and (2) current conditions-a scenario reflecting actual diversions with associated return flows. Our model results show that switching the cooling technologies at power plants in the eleven analyzed river basins to less water-intensive alternative designs can potentially reduce annual water diversions by 247-703 million m{sup 3}-enough water for 1.3-3.6 million people annually. We consider these results in a geographic context using geographic information system tools and then analyze volume reliability, which is a policymaker's metric that indicates the percentage of total demand actually supplied over a given period. This geographic and volume reliability analysis serves as a measure of drought susceptibility in response to changes in thermoelectric cooling technologies. While these water diversion savings do not alleviate all reliability concerns, the additional streamflow from the use of dry cooling alleviates drought concerns for some municipal water rights holders and might also be sufficient to uphold instream flow requirements for important bays and estuaries on the Texas Gulf coast.

  4. Characterization of drinking water treatment sludge after ultrasound treatment.

    Science.gov (United States)

    Zhou, Zhiwei; Yang, Yanling; Li, Xing; Zhang, Yang; Guo, Xuan

    2015-05-01

    Ultrasonic technology alone or the combination of ultrasound with alkaline or thermal hydrolysis as pretreatment for anaerobic digestion of activated sludge has been extensively documented. However, there are few reports on ultrasound as pretreatment of drinking water treatment sludge (DWTS), and thereby the characteristic variability of sonicated DWTS has not been fully examined. This research presents a lab-scale study on physical, chemical and biological characteristics of a DWTS sample collected from a water plant after ultrasonic treatment via a bath/probe sonoreactor. By doing this work, we provide implications for using ultrasound as pretreatment of enhanced coagulation of recycling sludge, and for the conditioning of water and wastewater mixed sludge by ultrasound combined with polymers. Our results indicate that the most vigorous DWTS disintegration quantified by particles' size reduction and organic solubilization is achieved with 5 W/ml for 30 min ultra-sonication (specific energy of 1590 kWh/kg TS). The Brunauer, Emmett and Teller (BET) specific surface area of sonicated DWTS flocs increase as ultra-sonication prolongs at lower energy densities (0.03 and 1 W/ml), while decrease as ultra-sonication prolongs at higher energy densities (3 and 5 W/ml). Additionally, the pH and zeta potential of sonicated DWTS slightly varies under all conditions observed. A shorter sonication with higher energy density plays a more effective role in restraining microbial activity than longer sonication with lower energy density.

  5. Resistance of Alkali Activated Water-Cooled Slag Geopolymer to Sulphate Attack

    Directory of Open Access Journals (Sweden)

    S. A. Hasanein

    2011-06-01

    Full Text Available Ground granulated blast furnace slag is a finely ground, rapidly chilled aluminosilicate melt material that is separated from molten iron in the blast furnace as a by-product. Rapid cooling results in an amorphous or a glassy phase known as GGBFS or water cooled slag (WCS. Alkaline activation of latent hydraulic WCS by sodium hydroxide and/or sodium silicate in different ratios was studied. Curing was performed under 100 % relative humidity and at a temperature of 38°C. The results showed that mixing of both sodium hydroxide and sodium silicate in ratio of 3:3 wt.,% is the optimum one giving better mechanical as well as microstructural characteristics as compared with cement mortar that has various cement content (cement : sand were 1:3 and 1:2. Durability of the water cooled slag in 5 % MgSO4 as revealed by better microstructure and high resistivity-clarifying that activation by 3:3 sodium hydroxide and sodium silicate, respectively is better than using 2 and 6 % of sodium hydroxide.

  6. Solar heating, cooling, and hot water systems installed at Richland, Washington. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-06-01

    Project Sunburst is a demonstration system for solar space heating and cooling and solar hot water heating for a 14,400 square foot office building in Richland, Washington. The project is part of the US Department of Energy's solar demonstration program, and became operational in April 1978. The solar system uses 6,000 square feet of flat-plate liquid collectors in a closed loop to deliver solar energy through a liquid--liquid heat exchanger to the building heat-pump duct work or 9,000-gallon thermal energy storage tank. A 25-ton Arkla solar-driven absorption chiller provides the cooling, in conjunction with a 2,000 gallon chilled water storage tank and reflective ponds on three sides of the building to reject surplus heat. A near-by building is essentially identical except for having conventional heat-pump heating and cooling, and can serve as an experimental control. An on-going public relations program has been provided from the beginning of the program and has resulted in numerous visitors and tour groups.

  7. Chemical and biological treatment technologies for leather tannery chemicals and wastewaters: a review.

    Science.gov (United States)

    Lofrano, Giusy; Meriç, Sureyya; Zengin, Gülsüm Emel; Orhon, Derin

    2013-09-01

    Although the leather tanning industry is known to be one of the leading economic sectors in many countries, there has been an increasing environmental concern regarding the release of various recalcitrant pollutants in tannery wastewater. It has been shown that biological processes are presently known as the most environmental friendly but inefficient for removal of recalcitrant organics and micro-pollutants in tannery wastewater. Hence emerging technologies such as advanced oxidation processes and membrane processes have been attempted as integrative to biological treatment for this sense. This paper, as the-state-of-the-art, attempts to revise the over world trends of treatment technologies and advances for pollution prevention from tannery chemicals and wastewater. It can be elucidated that according to less extent advances in wastewater minimization as well as in leather production technology and chemicals substitution, biological and chemical treatment processes have been progressively studied. However, there has not been a full scale application yet of those emerging technologies using advanced oxidation although some of them proved good achievements to remove xenobiotics present in tannery wastewater. It can be noted that advanced oxidation technologies integrated with biological processes will remain in the agenda of the decision makers and water sector to apply the best prevention solution for the future tanneries.

  8. An Innovative System for the Efficient and Effective Treatment of Non-Traditional Waters for Reuse in Thermoelectric Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    John Rodgers; James Castle

    2008-08-31

    , chemical oxygen demand (COD), and zinc. Similar to FGD waters, produced waters contained contaminants of concern that are predominantly inorganic (arsenic, cadmium, chlorides, chromium, copper, lead, mercury, nickel, sulfide, zinc, total dissolved solids), but also contained some organics (benzene, PAHs, toluene, total organic carbon, total suspended solids, and oil and grease). Constituents of concern that may cause chemical scaling, biofouling and corrosion, such as pH, hardness and ionic strength, and nutrients (P, K, and N) may also be found in all four non-traditional waters. NPDES permits were obtained for these non-traditional waters and these permit limits are summarized in tabular format within this report. These limits were used to establish treatment goals for this research along with toxicity values for Ceriodaphnia dubia, water quality criteria established by the US EPA, irrigation standards established by the United States Department of Agriculture (USDA), and reuse standards focused on minimization of damage to the power plant by treated waters. Constructed wetland treatment systems were designed for each non-traditional water source based on published literature reviews regarding remediation of the constituents of concern, biogeochemistry of the specific contaminants, and previous research. During this study, 4 non-traditional waters, which included ash basin water, cooling water, FGD water and produced water (PW) were obtained or simulated to measure constructed wetland treatment system performance. Based on data collected from FGD experiments, pilot-scale constructed wetland treatment systems can decrease aqueous concentrations of elements of concern (As, B, Hg, N, and Se). Percent removal was specific for each element, including ranges of 40.1% to 77.7% for As, 77.6% to 97.8% for Hg, 43.9% to 88.8% for N, and no measureable removal to 84.6% for Se. Other constituents of interest in final outflow samples should have aqueous characteristics sufficient for

  9. Experiences with electrochemical analysis of copper at the PPB-level in saline cooling water and in the water/steam cycle

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, K. [I/S Nordjyllandsvaerket, Vodskov (Denmark)

    1996-12-01

    Determination of trace amounts of copper in saline cooling water and in process water by differential pulse anodic stripping voltammetry combined with an UV-photolysis pretreatment is described. Copper concentrations well below 1 {mu}g/L may be analysed with a precision in the order of 10% and a high degree of accuracy. The basic principles of the method are described together with three applications covering analysis of cooling and process water samples. The analysis method has been applied to document the adherence of environmental limits for the copper uptake of cooling water passing brass condensers, to monitor the formation of protective layers of iron oxides on the cooling water side of brass condensers, and to study the transport of copper in water/steam cycles with heat exchangers and condensers of brass materials. (au)

  10. New and Green Multi-component Scaling and Corrosion Inhibitor for the Cooling Water of Central Air Conditioners

    Science.gov (United States)

    Li, Maodong; Dai, Chenlin; Yang, Bo; Qiao, Yue; Zhu, Zhiping

    2016-12-01

    A green multi-component inhibitor was developed in this study to obtain suitable scale and corrosion inhibitor for the cooling water treatment of central air conditioners. The inhibitor formulation consisted of hydrolyzed polymaleic anhydride/Tween-80/sodium N-lauroyl sarcosinate/tolyltriazole (named 4-HTSA). Weight loss test and electrochemical method were used to investigate the corrosion inhibition performance of 4-HTSA on A3 carbon steel and T2 red copper in synthetic cooling water, and the scale inhibition performance of 4-HTSA was studied by the calcium carbonate precipitation method. The influence of parameters, such as pH, temperature, scaling and corrosive ion, on 4-HTSA was researched. Scanning electron microscopy (SEM) and x-ray diffraction were used for examination of the scale, and corrosion coupons were analyzed by SEM/energy-dispersive x-ray spectroscopy. Results showed that 4-HTSA had excellent scale and corrosion inhibition performance and wide tolerance to pH, temperature and the concentration of scaling and corrosive ion. Polarization curves indicated that 4-HTSA was anodic inhibitor.

  11. Atmospheric forcing of cool subsurface water events in Bahía Culebra, Gulf of Papagayo, Costa Rica

    Directory of Open Access Journals (Sweden)

    Eric J. Alfaro

    2012-04-01

    Full Text Available Bahía Culebra, at Gulf of Papagayo on the north Pacific coast of Costa Rica, is an area of seasonal upwelling where more intense cooling events may occur during some boreal winter weeks mainly. To study these extreme cool events, records of nine sea subsurface temperature stations from 1998 to 2010 were analyzed. Five events associated with extremely cool temperatures in this region were identified from these records and taken as study cases. Sea temperatures decreased about 8-9ºC during these events and occurred while cold fronts were present in the Caribbean, with strong trade wind conditions over Central America. These strong wind conditions may have favored the offshore displacement of the sea surface water. The axis of Bahía Culebra runs northeastsouthwest, a condition that favors and triggers cool water events, mainly because the displaced water is replaced by water from deeper levels.

  12. Solar heating, cooling, and hot water systems installed at Richland, Washington

    Science.gov (United States)

    1979-01-01

    The project described is part of the U. S. Department of Energy's solar demonstration program, and became operational in April 1978. The solar system uses 6,000 square feet of flat-plate liquid collectors in a closed loop to deliver solar energy through a liquid-liquid heat exchanger to the building heat-pump duct work or 9,000-gallon thermal energy storage tank. A 25-ton Arkla solar-driven absorption chiller provides the cooling, in conjunction with a 2,000 gallon chilled water storage tank and reflective ponds on three sides of the building surplus heat. A near-by building is essentially identical except for having conventional heat-pump heating and cooling, and can serve as an experimental control. An on-going public relations program was provided from the beginning of the program, and resulted in numerous visitors and tour groups.

  13. The function of advanced treatment process in a drinking water treatment plant with organic matter-polluted source water.

    Science.gov (United States)

    Lin, Huirong; Zhang, Shuting; Zhang, Shenghua; Lin, Wenfang; Yu, Xin

    2017-04-01

    To understand the relationship between chemical and microbial treatment at each treatment step, as well as the relationship between microbial community structure in biofilms in biofilters and their ecological functions, a drinking water plant with severe organic matter-polluted source water was investigated. The bacterial community dynamics of two drinking water supply systems (traditional and advanced treatment processes) in this plant were studied from the source to the product water. Analysis by 454 pyrosequencing was conducted to characterize the bacterial diversity in each step of the treatment processes. The bacterial communities in these two treatment processes were highly diverse. Proteobacteria, which mainly consisted of beta-proteobacteria, was the dominant phylum. The two treatment processes used in the plant could effectively remove organic pollutants and microbial polution, especially the advanced treatment process. Significant differences in the detection of the major groups were observed in the product water samples in the treatment processes. The treatment processes, particularly the biological pretreatment and O3-biological activated carbon in the advanced treatment process, highly influenced the microbial community composition and the water quality. Some opportunistic pathogens were found in the water. Nitrogen-relative microorganisms found in the biofilm of filters may perform an important function on the microbial community composition and water quality improvement.

  14. Cooled radiofrequency denervation for treatment of sacroiliac joint pain: two-year results from 20 cases

    Directory of Open Access Journals (Sweden)

    Ho KY

    2013-07-01

    Full Text Available Kok-Yuen Ho,1 Mohamed Abdul Hadi,2 Koravee Pasutharnchat,2 Kian-Hian Tan21Pain Management Centre, Raffles Hospital, 2Pain Management Centre, Singapore General Hospital, SingaporeBackground: Sacroiliac joint pain is a common cause of chronic low back pain. Different techniques for radiofrequency denervation of the sacroiliac joint have been used to treat this condition. However, results have been inconsistent because the variable sensory supply to the sacroiliac joint is difficult to disrupt completely using conventional radiofrequency. Cooled radiofrequency is a novel technique that uses internally cooled radiofrequency probes to enlarge lesion size, thereby increasing the chance of completely denervating the sacroiliac joint. The objective of this study was to evaluate the efficacy of cooled radiofrequency denervation using the SInergyTM cooled radiofrequency system for sacroiliac joint pain.Methods: The charts of 20 patients with chronic sacroiliac joint pain who had undergone denervation using the SInergyTM cooled radiofrequency system were reviewed at two years following the procedure. Outcome measures included the Numeric Rating Scale for pain intensity, Patient Global Impression of Change, and Global Perceived Effect for patient satisfaction.Results: Fifteen of 20 patients showed a significant reduction in pain (a decrease of at least three points on the Numeric Rating Scale. Mean Numeric Rating Scale for pain decreased from 7.4 ± 1.4 to 3.1 ± 2.5, mean Patient Global Impression of Change was "improved" (1.4 ± 1.5, and Global Perceived Effect was reported to be positive in 16 patients at two years following the procedure.Conclusion: Cooled radiofrequency denervation showed long-term efficacy for up to two years in the treatment of sacroiliac joint pain.Keywords: ablation, chronic low back pain, intervention, neurotomy, sacroiliitis

  15. Experimental Evidence for a Liquid-Liquid Crossover in Deeply Cooled Confined Water

    Science.gov (United States)

    Cupane, Antonio; Fomina, Margarita; Piazza, Irina; Peters, Judith; Schirò, Giorgio

    2014-11-01

    In this work we investigate, by means of elastic neutron scattering, the pressure dependence of mean square displacements (MSD) of hydrogen atoms of deeply cooled water confined in the pores of a three-dimensional disordered SiO2 xerogel; experiments have been performed at 250 and 210 K from atmospheric pressure to 1200 bar. The "pressure anomaly" of supercooled water (i.e., a mean square displacement increase with increasing pressure) is observed in our sample at both temperatures; however, contrary to previous simulation results and to the experimental trend observed in bulk water, the pressure effect is smaller at lower (210 K) than at higher (250 K) temperature. Elastic neutron scattering results are complemented by differential scanning calorimetry data that put in evidence, besides the glass transition at about 170 K, a first-order-like endothermic transition occurring at about 230 K that, in view of the neutron scattering results, can be attributed to a liquid-liquid crossover. Our results give experimental evidence for the presence, in deeply cooled confined water, of a crossover occurring at about 230 K (at ambient pressure) from a liquid phase predominant at 210 K to another liquid phase predominant at 250 K; therefore, they are fully consistent with the liquid-liquid transition hypothesis.

  16. Stability analysis of supercritical-pressure light water-cooled reactor in constant pressure operation

    Energy Technology Data Exchange (ETDEWEB)

    Suhwan, JI; Shirahama, H.; Koshizuka, S.; Oka, Y. [Tokyo Univ., Tokai, Ibaraki (Japan). Nuclear Engineering Research Lab.

    2001-07-01

    The purpose of this study is to evaluate the thermal-hydraulic and the thermal-nuclear coupled stabilities of a supercritical pressure light water-cooled reactor. A stability analysis code at supercritical pressure is developed. Using this code, stabilities of full and partial-power reactor operating at supercritical pressure are investigated by the frequency-domain analysis. Two types of SCRs are analyzed; a supercritical light water reactor (SCLWR) and a supercritical water-cooled fast reactor (SCFR). The same stability criteria as Boiling Water Reactor are applied. The thermal-hydraulic stability of SCLWR and SCFR satisfies the criteria with a reasonable orifice loss coefficient. The decay ratio of the thermal-nuclear coupled stability in SCFR is almost zero because of a small coolant density coefficient of the fast reactor. The evaluated decay ratio of the thermal-nuclear coupled stability is 3,41 {approx} 10{sup -V} at 100% power in SCFR and 0,028 at 100% power in SCLWR. The sensitivity is investigated. It is found that the thermal-hydraulic stability is sensitive to the mass flow rate strongly and the thermal-nuclear coupled stability to the coolant density coefficient. The bottom power peak distribution makes the thermal-nuclear stability worse and the thermal-nuclear stability better. (author)

  17. Hydro-Potential Utilization of Cooling Water on the Hydro-Electric Power Plant Dalešice

    OpenAIRE

    Hudec, Martin; Haluza, Miloslav; Kubálek, Jiří

    2009-01-01

    Engineering solution of a surplus pressure head in a system of reversible machine unit's cooling water. Current technologies supplemented with Francis turbine or more precisely a centrifugal volute-type pump in turbine mode. It contains the layout for the basic extent of several various high-speeds with regard to maximum coverage of working conditions. Minimization of construction works on the structure of the cooling water inlet. Furthermore it includes an assignment of the annual power prod...

  18. Determining treatment frequency for controlling weeds on traffic islands using chemical and non-chemical weed control

    DEFF Research Database (Denmark)

    Rask, Anne Merete; Larsen, S.U.; Andreasen, Christian

    2013-01-01

    Many public authorities rely on the use of non-chemical weed control methods, due to stringent restrictions on herbicide use in urban areas. However, these methods usually require more repeated treatments than chemical weed management, resulting in increased costs of weed management. In order...... to investigate the efficacy of four non-chemical weed control methods and glyphosate treatment, experiments were carried out on traffic islands in the growing seasons 2005 and 2006. Three trial sites were each divided into six treatment areas, which were either treated with glyphosate, flame, steam, hot air....../flame, hot water or left untreated. The treatments were carried out at regular, predetermined intervals throughout the growing season in 2004, whereas in 2005 and 2006 how many treatments that were required to keep weed cover below a predetermined acceptance level of 2% were investigated. Percentage weed...

  19. Waste Water Management and Infectious Disease. Part II: Impact of Waste Water Treatment

    Science.gov (United States)

    Cooper, Robert C.

    1975-01-01

    The ability of various treatment processes, such as oxidation ponds, chemical coagulation and filtration, and the soil mantle, to remove the agents of infectious disease found in waste water is discussed. The literature concerning the efficiency of removal of these organisms by various treatment processes is reviewed. (BT)

  20. Waste Water Management and Infectious Disease. Part II: Impact of Waste Water Treatment

    Science.gov (United States)

    Cooper, Robert C.

    1975-01-01

    The ability of various treatment processes, such as oxidation ponds, chemical coagulation and filtration, and the soil mantle, to remove the agents of infectious disease found in waste water is discussed. The literature concerning the efficiency of removal of these organisms by various treatment processes is reviewed. (BT)