WorldWideScience

Sample records for controls infusion pumps

  1. 21 CFR 880.5725 - Infusion pump.

    Science.gov (United States)

    2010-04-01

    ... Infusion pump. (a) Identification. An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Infusion pump. 880.5725 Section 880.5725 Food and...

  2. Comparison between Infusion Pumps: Fentanyl/Ketamine and Fentanyl/Paracetamol in Pain control Following Tight and Leg Surgeries

    Directory of Open Access Journals (Sweden)

    Behnam Mahmoodiyeh

    2016-08-01

    Full Text Available Background: Adjuvants such as ketamine, promethazine and paracetamol could bring up patients satisfaction and control harmful effects of opioids besides lessening their needed doses, as seen by fentanyl/paracetamol and fentanyl/ketamine combination before. The current study headed to compare paracetamol and ketamine in addition to fentanyl applied by infusion pumps in order to pain relief following major surgery.Methods: Through a double blinded randomized clinical trial, patients between18 and 65 with elective surgery for tight or leg fractures with ASA Class 1 and 2 referring to a university hospital in Arak, a town in central region of Iran, were recruited and used infusion pump for their postoperative pain control. The participants were divided into cases and controls regarding using ketamine/fentanyl (KF or paracetamol/fentanyl (PF infusion pumps.Results: The mean pain score was totally 3.87 with higher value in KF (5.06 and lower in PF (4.5 immediately after finishing surgery and getting conscious when started using infusion pump. There was no statistical difference between the groups in this regard. Concerning the side effects of the applied medications, blood pressure and heart rate had no differences comparing the groups.Conclusion: This study showed that paracetamol used in infusion pump can be brilliant in pain control after major surgeries like what done in lower extremities and joint replacement while lessens opioid use. Although paracetamol was more effective than ketamine in the current trial, more qualified studies at bigger size and in other fields of surgery beside orthopedic ones would be useful to support the effects if applicable.Keywords: Infusion pump, Ketamine, Paracetamol, Fentanyl, Postoperative pain

  3. [Incorrect programming of a target controlled infusion pump. Case SENSAR of the trimester].

    Science.gov (United States)

    2014-10-01

    We report the case of a patient who underwent surgical aortic valve replacement. During general anaesthesia maintenance, the patient received a remifentanyl infusion via a target controlled infusion (TCI) system. The infusion pump that was prepared to deliver the infusion showed malfunction at the beginning of the surgery, so it was quickly replaced with a second pump. After a few minutes into the surgery, the patient presented with hypotension refractory to treatment. The remifentanyl syringe also emptied faster than expected. On reviewing the TCI pump, it was found that it was erroneously programmed for propofol instead of remifentanyl, thus the patient had received a very high dose of remifentanyl that was probably the cause of the haemodynamic disturbances. The incident was an error in equipment use, facilitated by hurry, lack of checking of the equipment prior to its use, and the complex and unclear design of the devices' screens. After analysis of this incident, all TCI pumps were reviewed, and all the programs for infrequently used drugs were deleted. Furthermore, 2 pumps were selected for exclusive use in the cardiac surgery theatre, one with propofol-only programming, and the other with remifentanyl-only programming, both clearly marked and situated in fixed places in that theatre. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  4. Scavenged body heat powered infusion pump

    International Nuclear Information System (INIS)

    Bell, Alexander; Ehringer, William D; McNamara, Shamus

    2013-01-01

    An infusion pump powered by body heat is investigated in this paper, with the goal of addressing the needs of dermal wound healing. The infusion pump incorporates a Knudsen gas pump, a type of thermally driven pump, to pneumatic push the pharmaceutical agent from a reservoir. Two designs are considered: an integrated pump and reservoir, and a design with cascaded pump and reservoir. Thermal models are developed for both pumps, and the simulations agree well with the experimental results. The integrated pump and reservoir design uses hydrophobic materials to prevent a flow from occurring unless the infusion pump is placed on a human body. Flow rates in the µL min −1 range for the integrated pump and reservoir, and approximately 70 µL min −1 for the cascaded pump were obtained. The dynamic behavior of the cascaded pump is described based on the thermal models. Multiple copies of the cascaded pump are easily made in series or parallel, to increase either the pressure or the flow rate. The flow rate of multiple pumps in series does not change, and the pressure of multiple pumps in parallel does not change. (paper)

  5. Determination of 24-hour insulin infusion pattern by an artificial endocrine pancreas for intravenous insulin infusion with a miniature pump

    DEFF Research Database (Denmark)

    Kølendorf, K; Christiansen, J S; Bojsen, J

    1981-01-01

    UNLABELLED: Intravenous insulin infusion with a glucose controlled insulin infusion system (GCIIS) is known to restore glucose homeostasis. A simpler approach to improve blood glucose regulation is preprogrammed intravenous insulin infusion with portable pumps without sensor-mediated feedback. We...... report a study designed to evaluate whether the preprogrammed insulin infusion pattern to be used in the miniature insulin infusion pump (MIIP) could be optimized by concomitant employment of the GCIIS for blood glucose control. Six juvenile-onset insulin-dependent diabetics (mean age 31 yrs) were...... studied. Mean blood glucose (MBG) was 6.2 mmol/l +/- 0.5 (SD) during glucose controlled infusion and 5.3 +/- 0.6 during the combined MIIP + GCIIS-day. The insulin requirements calculated from the s.c. regimen (56 U +/- 10 SD) were identical to the GCIIS-measured (51 U +/- 14) and to the amounts delivered...

  6. Comparison of infusion pumps calibration methods

    Science.gov (United States)

    Batista, Elsa; Godinho, Isabel; do Céu Ferreira, Maria; Furtado, Andreia; Lucas, Peter; Silva, Claudia

    2017-12-01

    Nowadays, several types of infusion pump are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring equipment, it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method, commonly used by National Metrology Institutes. The other calibration method, a secondary method, relies on an infusion device analyser (IDA) and is typically used by hospital maintenance offices. The suitability of the IDA calibration method was assessed by testing several infusion instruments at different flow rates using the gravimetric method. In addition, a measurement comparison between Portuguese Accredited Laboratories and hospital maintenance offices was performed under the coordination of the Portuguese Institute for Quality, the National Metrology Institute. The obtained results were directly related to the used calibration method and are presented in this paper. This work has been developed in the framework of the EURAMET projects EMRP MeDD and EMPIR 15SIP03.

  7. 75 FR 21641 - Infusion Pumps; Public Meeting; Request for Comments

    Science.gov (United States)

    2010-04-26

    ...] Infusion Pumps; Public Meeting; Request for Comments AGENCY: Food and Drug Administration, HHS. ACTION... announcing a public meeting regarding external infusion pumps. The purpose of the meeting is to inform the public about current problems associated with external infusion pump use, to help the agency identify...

  8. Developing a System for Integraded Automatic Control of Mutiple Infusion Pumps : The Multiplex infusion system

    NARCIS (Netherlands)

    Doesburg, Frank

    2013-01-01

    Most errors in ICUs are related to intravenous (IV) therapy. Previous studies suggested that hard to operate infusion pumps and the high cognitive workload for ICU nurses contribute to these errors. Conventional IV therapy requires separate lumens for incompatible IV drugs. This often requires the

  9. Quality-improvement analytics for intravenous infusion pumps.

    Science.gov (United States)

    Skledar, Susan J; Niccolai, Cynthia S; Schilling, Dennis; Costello, Susan; Mininni, Nicolette; Ervin, Kelly; Urban, Alana

    2013-04-15

    The implementation of a smart-pump continuous quality-improvement (CQI) program across a large health system is described, with an emphasis on key metrics for outcomes analyses and program refinement. Three years ago, the University of Pittsburgh Medical Center health system launched a CQI initiative to help ensure the safe use of 6000 smart pumps in its 14 inpatient facilities. A centralized team led by pharmacists is responsible for the retrieval and interpretation of smart-pump data, which is continuously transmitted to a main server. CQI findings are regularly posted on the health system's interdisciplinary intranet. Monitored metrics include rates of compliance with preprogrammed infusion limits, the top 20 drugs involved in alerts, drugs associated with alert-override rates of ≥90%, numbers of alerts by infusion type, nurse responses to alerts, and alert rate per drug library update. Based on the collected CQI data and site-specific requests, four systemwide updates of the smart-pump drug library were performed during the first 18 months of the program, reducing "nuisance alerts" by about 10% per update cycle and enabling targeted interventions to reduce rapid-infusion errors, other adverse drug events (ADEs), and pump-programming workarounds. Over one 12-month period, bedside alerts prompted nurses to reprogram or cancel continuous infusions an average of 400 times per month, potentially averting i.v. medication ADEs. A smart-pump CQI program is an effective tool for enhancing the safety of i.v. medication administration. The ongoing refinement of the drug library through the development and implementation of key interventions promotes the growth and sustainability of the smart-pump initiative systemwide.

  10. Quantitative assessment of haemolysis secondary to modern infusion pumps.

    Science.gov (United States)

    Poder, T G; Boileau, J-C; Lafrenière, R; Thibault, L; Carrier, N; de Grandmont, M-J; Beauregard, P

    2017-04-01

    Although most studies have shown that little haemolysis is induced by infusion pumps, there are some notable exceptions. Only limited data are available on the actual infusion pumps that are most used in hospitals in Quebec and elsewhere, namely, the Infusomat ® Space (peristaltic), Plum A+™ (piston) and Colleague ® CXE (shuttle) pumps. Haemolysis and potassium levels were compared before and after the use of the three different infusion pumps. Using 135 units of packed red blood cells (RBCs) aged from 10 to 28 days, 27 measurements were taken for each pump at various flow rates (30, 60, 150, 300 and 450 ml/h) and were compared with measurements taken before using the pumps. The range of flow rates was chosen to cover those of paediatric and adult transfusions. The shuttle- and piston-type pumps resulted in low haemolysis levels. The peristaltic-type pump produced significantly more haemolysis, which worsened at low flow rates, but the absolute value of haemolysis remained within the range recommended by the regulatory agencies in North America and Europe. Approximately two-thirds of the haemolysis produced by the peristaltic-type pump seemed to be secondary to the use of an antisiphon valve (ASV) on the transfusion line recommended by the manufacturer. Potassium levels did not increase with the use of the pumps. Modern infusion pumps widely used in hospitals in Quebec and elsewhere produce non-threatening levels of haemolysis during the transfusion of packed RBCs aged from 10 to 28 days. ASVs appear to induce additional haemolysis, and we do not recommend using them for blood transfusion. © 2017 International Society of Blood Transfusion.

  11. Graphical user interface simplifies infusion pump programming and enhances the ability to detect pump-related faults.

    Science.gov (United States)

    Syroid, Noah; Liu, David; Albert, Robert; Agutter, James; Egan, Talmage D; Pace, Nathan L; Johnson, Ken B; Dowdle, Michael R; Pulsipher, Daniel; Westenskow, Dwayne R

    2012-11-01

    Drug administration errors are frequent and are often associated with the misuse of IV infusion pumps. One source of these errors may be the infusion pump's user interface. We used failure modes-and-effects analyses to identify programming errors and to guide the design of a new syringe pump user interface. We designed the new user interface to clearly show the pump's operating state simultaneously in more than 1 monitoring location. We evaluated anesthesia residents in laboratory and simulated environments on programming accuracy and error detection between the new user interface and the user interface of a commercially available infusion pump. With the new user interface, we observed the number of programming errors reduced by 81%, the number of keystrokes per task reduced from 9.2 ± 5.0 to 7.5 ± 5.5 (mean ± SD), the time required per task reduced from 18.1 ± 14.1 seconds to 10.9 ± 9.5 seconds and significantly less perceived workload. Residents detected 38 of 70 (54%) of the events with the new user interface and 37 of 70 (53%) with the existing user interface, despite no experience with the new user interface and extensive experience with the existing interface. The number of programming errors and workload were reduced partly because it took less time and fewer keystrokes to program the pump when using the new user interface. Despite minimal training, residents quickly identified preexisting infusion pump problems with the new user interface. Intuitive and easy-to-program infusion pump interfaces may reduce drug administration errors and infusion pump-related adverse events.

  12. The development and evaluation of a subcutaneous infusion delivery system based on osmotic pump control and gas drive.

    Science.gov (United States)

    Xie, Xiangyang; Yang, Yang; Yang, Yanfang; Li, Zhiping; Zhang, Hui; Chi, Qiang; Cai, Xingshi; Mei, Xingguo

    2016-09-01

    A novel, self-administration drug delivery system for subcutaneous infusion was developed and evaluated. The device includes two main components: an osmotic tablet controlled gas actuator and a syringe catheter system. The sodium carbonate in the osmotic pump tablet will release into the surround citric acid solution and produce CO 2 gas, which will drive the drug solution into subcutaneous tissue. The key formulation factors of the osmotic tablet that would influence the infusion profiles of the device were investigated by single factor exploration. The formulation was optimized via a response surface methodology. With an 18 ± 4 min of lag time, the delivery system was able to infuse at an approximate zero-order up to 5.90 ± 0.37 h with a precision of 9.0% RSD (n = 6). A linear correlation was found for the infusion profile and the fitting equation was Y = 0.014X - 0.004 (r = 0.998). A temperature change of 4 °C was found to modify the flow rate by about 12.0%. In vivo results demonstrated that the present subcutaneous infusion device was similar to the commercial infusion pump, and it could bring a long and constant ampicillin plasma level with minimized fluctuations.

  13. The flow Rate Accuracy of Elastomeric Infusion Pumps After Repeated Filling.

    Science.gov (United States)

    Mohseni, Masood; Ebneshahidi, Amin

    2014-05-01

    One of the frequent applications of elastomeric infusion pumps is postoperative pain management. In daily practice, the disposable pumps get refilled with modified medication combinations in the successive days; although, the accuracy of infusion rates is unknown to clinicians. Our aim was to evaluate the effect of repeated filling on the delivery rate accuracy of an elastomeric pump available in our market. We examined 10 elastomeric infusion pumps (BOT-802, Nanchang Biotek Medical Device Company, China) with 100 mL capacity and nominal flow of 5 mL/h. Each pump was filled for three times, accounting for 30 series of experiments. A microset scaled in mL was used to measure the pump deliveries. Flow profile and reliability of infusion rate were analyzed after repeated use. The mean flow rate in the three series of measurements showed a gradual increase; however, the difference was not statistically significant (5.01 ± 0.07 vs. 5.03 ± 0.06 vs. 5.06 ± 0.08 mL/h; P = 0.81). The percentage of the flow rate error (deviation from 5 mL/h ± 15%) was 100% in the first and second hours of infusion, 96% in the third hour, 60% in the 20th hour and zero percent in the rest of the infusion time. This study indicated that the delivery rate accuracy of elastomeric infusion pumps is preserved after repeated usage. These laboratory findings suggested that elastomeric pumps could be safely refilled in the successive days to provide postoperative analgesia.

  14. Assessment of implantable infusion pumps for continuous infusion of human insulin in rats: potential for group housing

    DEFF Research Database (Denmark)

    Jensen, Vivi Flou Hjorth; Molck, Anne-Marie; Martensson, Martin

    2017-01-01

    compound in these studies, and a comparator model of persistent exposure by HI infusion from external pumps has recently been developed to support toxicological evaluation of long-acting insulin analogues. However, this model requires single housing of the animals. Developing an insulin-infusion model...... which allows group housing would therefore greatly improve animal welfare. The aim of the present study was to investigate the suitability of implantable infusion pumps for HI infusion in group-housed rats. Group housing of rats implanted with a battery-driven pump proved to be possible. Intravenous...... infusion of HI lowered blood glucose levels persistently for two weeks, providing a comparator model for use in two-week repeated-dose toxicity studies with new long-acting insulin analogues, which allows group housing, and thereby increasing animal welfare compared with an external infusion model....

  15. Continuous subcutaneous delivery of medications for home care palliative patients-using an infusion set or a pump?

    Science.gov (United States)

    Menahem, Sasson; Shvartzman, Pesach

    2010-09-01

    The purpose of this study was to evaluate safety, feasibility, and efficacy of continuous drug delivery by the subcutaneous route through a solution bag connected to an infusion set compared with an infusion pump in a home palliative care setting. Patients in need of continuous subcutaneous medication delivery for pain control, nausea, and/or vomiting were recruited. The study was designed as a double-blind, crossover study. The patient was connected to two parallel subcutaneous lines running simultaneously, connected together to a line entering the subcutaneous tissue. One line is connected to an infusion set and the other to a pump. The infusion set included a 500-cc solution bag connected to a 1.5-m plastic tube containing a drip chamber controlled by a roller clamp that is gravity driven without hyaluronidase. Active medications were randomly assigned to start in either administration method and switched after 24 h. An independent research assistant evaluated symptom control and side effects at baseline and every 24 h for 2 days using a structured questionnaire. Another independent research assistant connected the lines after adding medications and evaluated technical and clinical failures. Twenty-seven patients were recruited, and of them, 18 completed the study. Incidents in fluid administration were more common through the infusion set (18 times) compared to the pump (only twice). On the other hand, no clinical significant change was noted in the average symptom levels and side effects when medications were given through the infusion set versus the pump. No local edema or irritation was observed in either way of administration. In a home palliative care setting with a medical staff on call for 24 h, using medications for symptom control can be considered to be infused to a fluid solution bag through an infusion set instead of using a syringe driver or a pump when there is a responsible caregiver to follow up on the fluid. Subcutaneous constant drug delivery

  16. Low flow measurement for infusion pumps: implementation and uncertainty determination of the normalized method

    International Nuclear Information System (INIS)

    Cebeiro, J; Musacchio, A; Sardá, E Fernández

    2011-01-01

    Intravenous drug delivery is a standard practice in hospitalized patients. As the blood concentration reached depends directly on infusion rate, it is important to use safe devices that guarantee output accuracy. In pediatric intensive care units, low infusion rates (i.e. lower than 10.0 ml/h) are frequently used. Thus, it would be necessary to use control programs to search for deviations at this flow range. We describe the implementation of a gravimetric method to test infusion pumps in low flow delivery. The procedure recommended by the ISO/IEC 60601-2-24 standard was used being a reasonable option among the methods frequently used in hospitals, such as infusion pumps analyzers and volumetric cylinders. The main uncertainty sources affecting this method are revised and a numeric and graphic uncertainty analysis is presented in order to show its dependence on flow. Additionally, the obtained uncertainties are compared to those presented by an automatic flow analyzer. Finally, the results of a series of tests performed on a syringe infusion pump operating at low rates are shown.

  17. [Radiotherapy and implantable medical device: example of infusion pumps].

    Science.gov (United States)

    Abrous-Anane, S; Benhassine, S; Lopez, S; Cristina, K; Mazeron, J-J

    2013-12-01

    Indication for radiotherapy is often questioned for patients equipped with implantable medical devices like infusion pumps as the radiation tolerance is poor or not known. We report here on the case of a patient who we treated with pelvic radiotherapy for cervical cancer and who had an infusion pump in iliac fossa. We conducted a series of tests on five identical pumps that insured that the treatment protocol is harmless to the implanted device. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  18. Single-dose volume regulation algorithm for a gas-compensated intrathecal infusion pump.

    Science.gov (United States)

    Nam, Kyoung Won; Kim, Kwang Gi; Sung, Mun Hyun; Choi, Seong Wook; Kim, Dae Hyun; Jo, Yung Ho

    2011-01-01

    The internal pressures of medication reservoirs of gas-compensated intrathecal medication infusion pumps decrease when medication is discharged, and these discharge-induced pressure drops can decrease the volume of medication discharged. To prevent these reductions, the volumes discharged must be adjusted to maintain the required dosage levels. In this study, the authors developed an automatic control algorithm for an intrathecal infusion pump developed by the Korean National Cancer Center that regulates single-dose volumes. The proposed algorithm estimates the amount of medication remaining and adjusts control parameters automatically to maintain single-dose volumes at predetermined levels. Experimental results demonstrated that the proposed algorithm can regulate mean single-dose volumes with a variation of 98%. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Infusion of iloprost without a peristaltic pump: Safety and tolerability

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2013-04-01

    Full Text Available Introduction: Iloprost is a potent prostacyclin (PGI2 analogue that is effective in the treatment of peripheral arterial disease, vasculitis, pulmonary hypertension, and secondary Raynaud’s phenomenon. Intravenous infusions are generally administered with the aid of a peristaltic pump to reduce the risk of adverse reactions caused by unintentional increases in the infusion rate. This increases the cost of care in terms of equipment and personnel and may limit the use of this drug. Materials and methods: We retrospectively analyzed 18,432 iloprost infusions administered between 1999 and 2009 to 272 patients with systemic sclerosis (n = 253 and 19 with peripheral arterial disease (n = 19. All infusions were administered in the day hospital over 6 h with a normal IV set-up with a roller flow regulator. Flow rates were set to deliver iloprost at 1-2 ng/kg/min. Rates were verified by direct drop counts during the first 15-20 minutes of the infusion and at each subsequent check. Results: There were no adverse events that were fatal, life-threatening, or associated with prolongation of hospitalization and very few events requiring intensive care or continuous monitoring. The latter included 4 cases of tachycardia/arrhythmia (extrasystoles in most cases, 3 cases of hypotension (systolic pressure < 80 mmHg, and 2 cases of hypertension (BP > 170/100 mmHg. All other adverse reactions were mild, reversible, and similar to those seen with iloprost infusion with peristaltic pump. Only one patient had to be switched to another prostanoid (due to intolerance. Discussion: Iloprost infusion administered with a normal IV flow regulator appears to be as safe, well tolerated, and effective as traditional infusion with a peristaltic pump.

  20. Haemolysis following rapid experimental red blood cell transfusion--an evaluation of two infusion pumps

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; Sprogøe-Jakobsen, U; Pedersen, C M

    1998-01-01

    The vast majority of infusion pumps used for rapid transfusion of large amounts of blood have never been properly examined regarding their influence on the quality of the red blood cells (RBCs) infused. In this study, we evaluated the effect of two different infusion pumps on the degree of RBC...

  1. Using miniature osmotic infusion pumps to maintain tritiated thymidine exposure to cells in culture

    International Nuclear Information System (INIS)

    Neely, J.E.; Hake, D.A.

    1982-01-01

    To provide a constant level of tracer doses of tritiated thymidine to cultured cells during continuous infusion, miniature osmotic infusion pumps were used to provide replacement thymidine. By determining the loss of isotope from the media during nonreplacement, the rate of constant infusion replacement to maintain thymidine levels was calculated. The replacement rates were similar for the three cell lines examined and allowed a standard osmotic pump infusion

  2. Comparative analytics of infusion pump data across multiple hospital systems.

    Science.gov (United States)

    Catlin, Ann Christine; Malloy, William X; Arthur, Karen J; Gaston, Cindy; Young, James; Fernando, Sudheera; Fernando, Ruchith

    2015-02-15

    A Web-based analytics system for conducting inhouse evaluations and cross-facility comparisons of alert data generated by smart infusion pumps is described. The Infusion Pump Informatics (IPI) project, a collaborative effort led by research scientists at Purdue University, was launched in 2009 to provide advanced analytics and tools for workflow analyses to assist hospitals in determining the significance of smart-pump alerts and reducing nuisance alerts. The IPI system allows facility-specific analyses of alert patterns and trends, as well as cross-facility comparisons of alert data uploaded by more than 55 participating institutions using different types of smart pumps. Tools accessible through the IPI portal include (1) charts displaying aggregated or breakout data on the top drugs associated with alerts, numbers of alerts per device or care area, and override-to-alert ratios, (2) investigative reports that can be used to characterize and analyze pump-programming errors in a variety of ways (e.g., by drug, by infusion type, by time of day), and (3) "drill-down" workflow analytics enabling users to evaluate alert patterns—both internally and in relation to patterns at other hospitals—in a quick and efficient stepwise fashion. The formation of the IPI analytics system to support a community of hospitals has been successful in providing sophisticated tools for member facilities to review, investigate, and efficiently analyze smart-pump alert data, not only within a member facility but also across other member facilities, to further enhance smart pump drug library design. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  3. A review of the security of insulin pump infusion systems.

    Science.gov (United States)

    Paul, Nathanael; Kohno, Tadayoshi; Klonoff, David C

    2011-11-01

    Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues. © 2011 Diabetes Technology Society.

  4. Safety and efficacy of gas-forced infusion (air pump) in coaxial phacoemulsification.

    Science.gov (United States)

    Chaudhry, Prashaant; Prakash, Gaurav; Jacob, Soosan; Narasimhan, Smita; Agarwal, Sunita; Agarwal, Amar

    2010-12-01

    To evaluate the safety and efficacy of gas-forced infusion (air pump) in uncomplicated coaxial phacoemulsification. Dr. Agarwal's Eye Hospital, Chennai, India. Comparative case series. Specular microscopy and optical coherence tomography were used to analyze the endothelium, central macular thickness (CMT), and peripapillary retinal nerve fiber layer (RNFL) thickness before and approximately 1, 7, 30, and 90 days after coaxial phacoemulsification with (infusion group) or without (control group) gas-forced infusion. Surgical time, surge, phaco energy, irrigation fluid volume, surgical ease, complications, and visual gain in the 2 groups were compared. The mean endothelial cell loss was lower in the infusion group than in the control group (6.98% ± 8.46% [SD] versus 10.54% ± 11.24%; P = .045) and the irrigation/aspiration time significantly shorter (54 ± 39 seconds versus 105 ± 84 seconds; P = .0001). The surgery was rated as easier with gas-forced infusion (scale 1 to 10: mean 8.3 ± 2.1 versus 6.6 ± 1.6; P = .00002). However, the amount of irrigating fluid volume was higher in the infusion group (117 ± 37 mL versus 94 ± 41 mL; P = .003). No surge occurred in the infusion group; it occurred a mean of 3.00 ± 4.16 times in the control group (PGas-forced infusion was safe and effective in controlling surge and increased the safety, ease, and speed of coaxial phacoemulsification. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Outlook Analgesic Infusion Pumps Market Size - Trends and Opportunity Forecast to 2023

    OpenAIRE

    nishthavohra

    2018-01-01

    Analgesic infusion pumps are instruments used to carry analgesic drugs directly into patient’s body directly for pain management. Analgesic drugs provide relief from chronic disorders, including complex regional pain syndrome (CRPS), failed back syndrome pain, myocardial infarction, pneumonia, myocardial ischemia, post-operative pain, and hypertension. Lidocaine, phenol and morphine are some of the common medicines used in analgesic infusion pumps. Explore Report At: https://www.psmarket...

  6. Insulin appearance of subcutaneously infused insulin: influence of the basal rate pulse interval of the infusion pump.

    Science.gov (United States)

    Birch, K; Hildebrandt, P; Jensen, B M; Kühl, C; Brange, J

    1985-05-01

    To compare the metabolic control and the pharmacokinetics of infused insulin using an insulin pump (Auto-Syringe AS 6C) which provides the basal rate in pulses every 2-10 min with a pump (Medix Syringe Driver 209) providing the basal rate in pulses every 15-60 min, 6 C-peptide negative diabetic patients received, in random order, identical, but individual, insulin treatment during one 4-day period using the Auto-Syringe pump and another 4-day period using the Medix pump. On the fourth day of each period, blood glucose and plasma-free insulin were estimated every 30 min for 7 hr and every 5 min for the next hour. Plasma-free insulin was significantly higher on 3 time points out of the 26 possible when using the Medix pump, but this was not reflected in the blood glucose concentrations which were similar in the 2 periods. The results indicate that, from a metabolic and pharmacokinetic point of view, insulin pumps working with larger intervals between the basal rate pulses are just as good as the more technically advanced and hence often more expensive pumps which provide the basal rate in more and smaller pulses.

  7. Clinical safety of magnetic resonance imaging in patients with implanted SynchroMed EL infusion pumps

    International Nuclear Information System (INIS)

    Diehn, Felix E.; Wood, Christopher P.; Watson, Robert E.; Hunt, Christopher H.; Mauck, William D.; Burke, Michelle M.

    2011-01-01

    Patients with implanted SynchroMed spinal infusion pumps (Medtronic, Inc., Minneapolis, MN) routinely undergo magnetic resonance imaging at our institution. In August 2008, Medtronic issued an urgent medical device correction report regarding several pumps. Because of the rare potential ''for a delay in the return of proper drug infusion'' and ''for a delay in the logging of motor stall events,'' ''a patient's pump must be interrogated after MRI exposure in order to confirm proper pump functionality.'' This is particularly important in patients receiving intrathecal baclofen, for whom a delay in return of proper pump infusion could lead to life-threatening baclofen withdrawal syndrome. The objective of this report is to present our experience and protocol of performing magnetic resonance imaging in patients with implanted SynchroMed EL pumps. We retrospectively reviewed records of 86 patients with implanted SynchroMed EL spinal infusion pumps who underwent 112 examinations on 1.5-T magnetic resonance imaging scanners from September 1, 1998 to July 7, 2004. No SynchroMed EL pumps were damaged by magnetic resonance imaging, and the programmable settings remained unchanged in all patients. Our data suggest that SynchroMed EL pump malfunction is indeed rare after routine clinical 1.5-T magnetic resonance imaging examinations. However, based on the Medtronic correction report, we perform pump interrogation before and after imaging. (orig.)

  8. Clinical safety of magnetic resonance imaging in patients with implanted SynchroMed EL infusion pumps

    Energy Technology Data Exchange (ETDEWEB)

    Diehn, Felix E.; Wood, Christopher P.; Watson, Robert E.; Hunt, Christopher H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Mauck, William D. [Mayo Clinic, Department of Anesthesiology, Rochester, MN (United States); Burke, Michelle M. [Mayo Clinic, Department of Psychiatry and Psychology, Rochester, MN (United States)

    2011-02-15

    Patients with implanted SynchroMed spinal infusion pumps (Medtronic, Inc., Minneapolis, MN) routinely undergo magnetic resonance imaging at our institution. In August 2008, Medtronic issued an urgent medical device correction report regarding several pumps. Because of the rare potential ''for a delay in the return of proper drug infusion'' and ''for a delay in the logging of motor stall events,'' ''a patient's pump must be interrogated after MRI exposure in order to confirm proper pump functionality.'' This is particularly important in patients receiving intrathecal baclofen, for whom a delay in return of proper pump infusion could lead to life-threatening baclofen withdrawal syndrome. The objective of this report is to present our experience and protocol of performing magnetic resonance imaging in patients with implanted SynchroMed EL pumps. We retrospectively reviewed records of 86 patients with implanted SynchroMed EL spinal infusion pumps who underwent 112 examinations on 1.5-T magnetic resonance imaging scanners from September 1, 1998 to July 7, 2004. No SynchroMed EL pumps were damaged by magnetic resonance imaging, and the programmable settings remained unchanged in all patients. Our data suggest that SynchroMed EL pump malfunction is indeed rare after routine clinical 1.5-T magnetic resonance imaging examinations. However, based on the Medtronic correction report, we perform pump interrogation before and after imaging. (orig.)

  9. Platelet transfusion in chemotherapy patients: comparison of the effect of intravenous infusion pumps versus gravity transfusion.

    Science.gov (United States)

    Meess, A

    2015-01-01

    Platelet concentrates are given to patients suffering with severe thrombocytopenia usually by a gravity transfusion procedure. Increasing patient numbers that are in need of this treatment increase the pressure on hospital staff and space. In order to combat time issues, the use of medical devices such as intravenous infusion pumps are thought to be beneficial for time and simultaneously for safety in transfusion practices. By using infusion pumps, platelet concentrates can be transfused in less time and provide accurate volume measurements. Manufacturers of infusion pumps claim that these devices are safe to be used for blood products including platelet concentrates. However, published studies were performed on older models and newer devices are on the market now. The purpose of this study is to evaluate infusion pumps, which are claimed to be suitable for blood products and to investigate the impact the pumps had on platelets. Furthermore, the study revealed if the intravenous infusion pumps are safe to be used for platelet transfusion as claimed by manufacturers. A simulated transfusion was performed using the Carefusion Alaris GP Plus volumetric pump and Fresenius Kabi Volumat Agilia infusion pump. Samples were taken from expired platelet concentrates before and after passage through the pump. All samples were investigated for full blood count that included platelet count, mean platelet volume (MPV), platelet distribution width (PDW) and a plateletcrit (PCT). The samples were then centrifuged to achieve platelet-poor plasma and then tested for lactate dehydrogenase (LDH). A power calculation performed on the statistical power analysis program G*power indicated a requirement of 82 samples for a power of 80%. Statistical analysis was performed with the IBM SPSS statistic software. A paired sample t-test was used to calculate mean, standard deviation and P values for the infusion pumps used. The Wilcoxon Signed Rank Test was used to evaluate results that had a non

  10. Continuous quality improvement using intelligent infusion pump data analysis.

    Science.gov (United States)

    Breland, Burnis D

    2010-09-01

    The use of continuous quality-improvement (CQI) processes in the implementation of intelligent infusion pumps in a community teaching hospital is described. After the decision was made to implement intelligent i.v. infusion pumps in a 413-bed, community teaching hospital, drug libraries for use in the safety software had to be created. Before drug libraries could be created, it was necessary to determine the epidemiology of medication use in various clinical care areas. Standardization of medication administration was performed through the CQI process, using practical knowledge of clinicians at the bedside and evidence-based drug safety parameters in the scientific literature. Post-implementation, CQI allowed refinement of clinically important safety limits while minimizing inappropriate, meaningless soft limit alerts on a few select agents. Assigning individual clinical care areas (CCAs) to individual patient care units facilitated customization of drug libraries and identification of specific CCA compliance concerns. Between June 2007 and June 2008, there were seven library updates. These involved drug additions and deletions, customization of individual CCAs, and alterations of limits. Overall compliance with safety software use rose over time, from 33% in November 2006 to over 98% in December 2009. Many potentially clinically significant dosing errors were intercepted by the safety software, prompting edits by end users. Only 4-6% of soft limit alerts resulted in edits. Compliance rates for use of infusion pump safety software varied among CCAs over time. Education, auditing, and refinement of drug libraries led to improved compliance in most CCAs.

  11. Iloprost infusion by a new device as a portable syringe pump: safety, tolerability and agreement

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2012-12-01

    Full Text Available Background Iloprost, prostacyclin (PGI2 analogue, effective in treatment of peripheral arterial disease, secondary Raynaud's phenomenon (RP to connective tissue disease (CTD, vasculitis, pulmonary hypertension, is usually infused through peristaltic pump, or recently through a flow regulator.Materials and methods We tested a new portable syringe pump (Pompa Infonde®, Italfarmaco S.p.A., Cinisello Balsamo, Milano on 120 patients affected by RP to CTD and cryoglobulinaemia, in iloprost therapy with a flow regulator.Results Iloprost infused through portable syringe pump is better tolerated, better appreciated by the patients and nurses and no difference was observed on therapeutic effects, with a lower incidence of side effects statistically significant. Only 3 patients were unable to tolerate the device (2 for changes in pressure and 1 for fear and shifted to traditional method of iloprost infusion.Conclusions Iloprost infusion through the portable syringe Pompa Infonde® appears to be safe, better tolerated, more acceptable and equally effective compared to infusion through a flow regulator.

  12. Impact of Computerized Order Entry to Pharmacy Interface on Order-Infusion Pump Discrepancies

    Directory of Open Access Journals (Sweden)

    Rebecca A. Russell

    2015-01-01

    Full Text Available Background. The ability of safety technologies to decrease errors, harm, and risk to patients has yet to be demonstrated consistently. Objective. To compare discrepancies between medication and intravenous fluid (IVF orders and bedside infusion pump settings within a pediatric intensive care unit (PICU before and after implementation of an interface between computerized physician order entry (CPOE and pharmacy systems. Methods. Within a 72-bed PICU, medication and IVF orders in the CPOE system and bedside infusion pump settings were collected. Rates of discrepancy were calculated and categorized by type. Results were compared to a study conducted prior to interface implementation. Expansion of PICU also occurred between study periods. Results. Of 455 observations, discrepancy rate decreased for IVF (p=0.01 compared to previous study. Overall discrepancy rate for medications was unchanged; however, medications infusing without an order decreased (p<0.01, and orders without corresponding infusion increased (p<0.05. Conclusions. Following implementation of an interface between CPOE and pharmacy systems, fewer discrepancies between IVF orders and infusion pump settings were observed. Discrepancies for medications did not change, and some types of discrepancies increased. In addition to interface implementation, changes in healthcare delivery and workflow related to ICU expansion contributed to observed changes.

  13. Effect of insulin pump infusion on comprehensive stress state of ...

    African Journals Online (AJOL)

    Effect of insulin pump infusion on comprehensive stress state of patients with diabetic ketoacidosis. ... Relevant diabetes-associated serum indices, oxidative stress and stress hormone levels were compared between the ... from 32 Countries:.

  14. Precision flow-controlled rubidium-82 generator for bolus and constant infusion studies

    International Nuclear Information System (INIS)

    Yano, Y.

    1981-01-01

    A unique flow rate controller and large reservoir pumping system have been developed for infusing rubidium-82 intravenously at bolus, constant, or variable infusion rates. Using rubidium-82 and the positron ring detector tomograph, extraction or flow information can be obtained in studies of the heart, head, or kidneys

  15. Organizational, Cultural, and Psychological Determinants of Smart Infusion Pump Work Arounds: A Study of 3 U.S. Health Systems.

    Science.gov (United States)

    Dunford, Benjamin B; Perrigino, Matthew; Tucker, Sharon J; Gaston, Cynthia L; Young, Jim; Vermace, Beverly J; Walroth, Todd A; Buening, Natalie R; Skillman, Katherine L; Berndt, Dawn

    2017-09-01

    We investigated nurse perceptions of smart infusion medication pumps to provide evidence-based insights on how to help reduce work around and improve compliance with patient safety policies. Specifically, we investigated the following 3 research questions: (1) What are nurses' current attitudes about smart infusion pumps? (2) What do nurses think are the causes of smart infusion pump work arounds? and (3) To whom do nurses turn for smart infusion pump training and troubleshooting? We surveyed a large number of nurses (N = 818) in 3 U.S.-based health care systems to address the research questions above. We assessed nurses' opinions about smart infusion pumps, organizational perceptions, and the reasons for work arounds using a voluntary and anonymous Web-based survey. Using qualitative research methods, we coded open-ended responses to questions about the reasons for work arounds to organize responses into useful categories. The nurses reported widespread satisfaction with smart infusion pumps. However, they reported numerous organizational, cultural, and psychological causes of smart pump work arounds. Of 1029 open-ended responses to the question "why do smart pump work arounds occur?" approximately 44% of the causes were technology related, 47% were organization related, and 9% were related to individual factors. Finally, an overwhelming majority of nurses reported seeking solutions to smart pump problems from coworkers and being trained primarily on the job. Hospitals may significantly improve adherence to smart pump safety features by addressing the nontechnical causes of work arounds and by providing more leadership and formalized training for resolving smart pump-related problems.

  16. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature

    Directory of Open Access Journals (Sweden)

    Ana Maria Miranda Martins Wilson

    Full Text Available ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. Results: all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. Conclusion: infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies.

  17. Physical and Chemical Stability of Urapidil in 0.9% Sodium Chloride in Elastomeric Infusion Pump.

    Science.gov (United States)

    Tomasello, Cristina; Leggieri, Anna; Rabbia, Franco; Veglio, Franco; Baietto, Lorena; Fulcheri, Chiara; De Nicolò, Amedeo; De Perri, Giovanni; D'Avolio, Antonio

    2016-01-01

    Urapidil is an antihypertensive agent, usually administered through intravenous bolus injection, slow-intravenous infusion, or continuous-drug infusion by perfusor. Since to date no evidences are available on drug stability in elastomeric pumps, patients have to be hospitalized. The purpose of this study was to validate an ultra-performance liquid chromatographic method to evaluate urapidil stability in an elastomeric infusion pump, in order to allow continuous infusion as home-care treatment. Analyses were conducted by diluting urapidil in an elastomeric pump. Two concentrations were evaluated: 1.6 mg/mL and 3.3 mg/mL. For the analyses, a reverse-phase ultra-performance liquid chromatographic- photodiode array detection instrument was used. Stressed degradation, pH changes, and visual clarity were used as stability indicators up to 10 days after urapidil solution preparation. The drug showed no more than 5% degradation during the test period at room temperature. No pH changes and no evidences of incompatibility were observed. Stress tests resulted in appreciable observation of degradation products. Considering the observed mean values, urapidil hydrochloride in sodium chloride 0.9% in elastomeric infusion pumps is stable for at least 10 days. These results indicate that this treatment could be administered at home for a prolonged duration (at least 7 days) with a satisfactory response. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  18. In vitro viability effects on apheresis and buffy-coat derived platelets administered through infusion pumps

    Directory of Open Access Journals (Sweden)

    Sandgren P

    2014-12-01

    Full Text Available Per Sandgren,1,2 Veronica Berggren,3 Carl Westling,1,2 Viveka Stiller1 1Department of Clinical Immunology and Transfusion Medicine, Karolinska University Hospital, 2Department of Laboratory Medicine, Karolinska Institutet, 3Department of Neonatology, Karolinska University Hospital, Stockholm, SwedenBackground: Different infusion pump systems as well as gravity infusion have been widely used in neonatal transfusion. However, the limited number of published studies describing the use of infusion pumps on platelets illustrates the necessity for more robust data.Methods: To evaluate the potential in vitro effects on the cellular, metabolic, functional and phenotypic properties of platelets, we set up a four-arm paired study simultaneously comparing the use of different infusion pumps (Alaris® CC/GP with unexposed platelets. The platelet units (n=8 were either produced by the apheresis technique and suspended in 100% plasma or derived from buffy coats to yield platelet units stored in approximately 30% plasma and 70% SSP+. Fresh and 5-day old platelets were tested.Results: Regardless of the production system or storage time used, no significant differences were observed in glucose and lactate concentration, pH, adenosine triphosphate levels, response to extent of shape change, hypotonic shock response reactivity, and CD62P expression. Similarly, no differences were observed in expression of the conformational epitope on glycoprotein IIb/IIIa, determined using procaspase-activating compound 1, or in the expression of CD42b and platelet-endothelial cell adhesion molecule-1 in a comparison between platelets administered through infusion pumps versus unexposed platelets.Conclusion: Using Alaris CC/GP infusion pumps had no influence on the cellular, functional, and phenotypic in vitro properties of platelets. This fact seems not to be affected by different production systems or storage time.Keywords: platelets, neonatal platelet transfusion

  19. Comparative Dose Accuracy of Durable and Patch Insulin Infusion Pumps

    Science.gov (United States)

    Jahn, Luis G.; Capurro, Jorge J.; Levy, Brian L.

    2013-01-01

    Background: As all major insulin pump manufacturers comply with the international infusion pump standard EN 60601-2-24:1998, there may be a general assumption that all pumps are equal in insulin-delivery accuracy. This research investigates single-dose and averaged-dose accuracy of incremental basal deliveries for one patch model and three durable models of insulin pumps. Method: For each pump model, discrete single doses delivered during 0.5 U/h basal rate infusion over a 20 h period were measured using a time-stamped microgravimetric system. Dose accuracy was analyzed by comparing single doses and time-averaged doses to specific accuracy thresholds (±5% to ±30%). Results: The percentage of single doses delivered outside accuracy thresholds of ±5%, ±10%, and ±20% were as follows: Animas OneTouch® Ping® (43.2%, 14.3%, and 1.8%, respectively), Roche Accu-Chek® Combo (50.6%, 24.4%, and 5.5%), Medtronic Paradigm® RevelTM/VeoTM (54.2%, 26.7%, and 6.6%), and Insulet OmniPod® (79.1%, 60.5%, and 34.9%). For 30 min, 1 h, and 2 h averaging windows, the percentage of doses delivered outside a ±15% accuracy were as follows: OneTouch Ping (1.0%, 0.4%, and 0%, respectively), Accu-Chek Combo (4.2%, 3.5%, and 3.1%), Paradigm Revel/Veo (3.9%, 3.1%, and 2.2%), and OmniPod (33.9%, 19.9%, and 10.3%). Conclusions: This technical evaluation demonstrates significant differences in single-dose and averaged-dose accuracy among the insulin pumps tested. Differences in dose accuracy were most evident between the patch pump model and the group of durable pump models. Of the pumps studied, the Animas OneTouch Ping demonstrated the best single-dose and averaged-dose accuracy. Further research on the clinical relevance of these findings is warranted. PMID:23911184

  20. Strontium-rubidium infusion pump with in-line dosimetry

    International Nuclear Information System (INIS)

    Barker, S.L.; Loberg, M.D.

    1986-01-01

    A strontium-rubidium infusion system is described which consists of: (a) means for generating rubidium 82 in a solution which can be infused into a patient; (b) means for infusing the solution into a patient; (c) means for measuring the radioactivity present in the solution as it is infused into the patient; and (d) means for controlling the means for infusing in response to the amount of radioactivity which has been infused into the patient

  1. Improved usability of a multi-infusion setup using a central control display

    NARCIS (Netherlands)

    Doesburg, Frank; Cnossen, Fokeltje; Dieperink, Willem; Bult, Wouter; Nijsten, Maarten W

    2016-01-01

    Infusion pumps are often associated with poor usability and an increased likelihood of medication errors [1]. Critically ill patients in the intensive care unit (ICU) usually receive multiple infusions simultaneously, which increases the likelihood of pump-related errors. Furthermore, the ICU is

  2. Tolerability, safety and efficacy of Iloprost infusion without peristaltic pump in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    S. Tosi

    2011-09-01

    Full Text Available Objective. To evaluate safety, tolerability and efficacy on Raynaud’s phenomenon (Rp of iloprost infusion without peristaltic pump in patients with systemic sclerosis (SSc. Patients and methods. The inclusion criteria were diagnosis of SSc, age between 18 and 65 years, presence of Rp, and absence of any controindication to the use of iloprost. The treatment was carried out in a day hospital setting and consisted first of 5 consecutive days of iloprost infusion (from an initial dose of 1.0 ng/Kg/min up to 2 ng/kg/min, and then of 2 days of infusions at the maximum possible dose every 45 days for one year. All of the adverse events were carefully recorded and the changes in the Rp were measured by a 5 grade scale (worsened, unmodified, slightly improved, very improved, disappeared. Results. Thirty-eight SSc patients (all females, mean age 49 years (range 18.5-65, disease duration 1.5 years (range 0.5-10.8 were enrolled in the study. During the first cycle of therapy, 14 avderse events occurred in 11 (28.9% patients and during the next cycles, 3 adverse events were seen in 3 (7.9% patients. In all of the cases they were mild and transient. Rp was considered very improved in 15 (39.5% patients, slightly improved in 13 (34.2%, unmodified in 8 (21% and worse in 2 (5.2%. Discussion. In this study intravenous iloprost without peristaltic pump proved to be safe, well tolerated, and as effective as traditional infusion through peristaltic pump in improving Rp in patients with SSc.

  3. Benefits of smart pumps for automated changeovers of vasoactive drug infusion pumps: a quasi-experimental study.

    Science.gov (United States)

    Cour, M; Hernu, R; Bénet, T; Robert, J M; Regad, D; Chabert, B; Malatray, A; Conrozier, S; Serra, P; Lassaigne, M; Vanhems, P; Argaud, L

    2013-11-01

    Manual changeover of vasoactive drug infusion pumps (CVIP) frequently lead to haemodynamic instability. Some of the newest smart pumps allow automated CVIP. The aim of this study was to compare automated CVIP with manual 'Quick Change' relays. We performed a prospective, quasi-experimental study, in a university-affiliated intensive care unit (ICU). All adult patients receiving continuous i.v. infusion of vasoactive drugs were included. CVIP were successively performed manually (Phase 1) and automatically (Phase 2) during two 6-month periods. The primary endpoint was the frequency of haemodynamic incidents related to the relays, which were defined as variations of mean arterial pressure >15 mm Hg or heart rate >15 bpm. The secondary endpoints were the nursing time dedicated to relays and the number of interruptions in care because of CVIP. A multivariate mixed effects logistic regression was fitted for analytic analysis. We studied 1329 relays (Phase 1: 681, Phase 2: 648) from 133 patients (Phase 1: 63, Phase 2: 70). Incidents related to CVIP decreased from 137 (20%) in Phase 1 to 73 (11%) in Phase 2 (Ppumps in limiting the frequency of haemodynamic incidents related to relays and in reducing the nursing workload.

  4. A comparison of the hourly output between the Ambu® Smart-Infuser™ Pain Pump and the On-Q Pump® with Select-A-Flow™ Variable Rate Controller with standard and overfill volumes.

    Science.gov (United States)

    Iliev, Peter; Bhalla, Tarun; Tobias, Joseph D

    2016-04-01

    The Ambu Smart-Infuser Pain Pump and the On-Q Pump with Select-a-Flow Variable Rate Controller are elastomeric devices with a flow regulator that controls the rate of infusion of a local anesthetic agent through a peripheral catheter. As a safety evaluation, we evaluated the infusion characteristics of these two devices when filled with manufacturer recommended standard volumes and when overfilled with a volume 50% in excess of that which is recommended. Nineteen disposable devices from the two manufacturers were used in this study. Nine were filled with 0.9% normal saline according to the respective manufacturers' recommendations (four Ambu pumps were filled with 650 ml and five On-Q pumps were filled with 550 ml) and 10 devices were 150% overfilled (five Ambu pumps were filled with 975 ml and five On-Q pumps were filled with 825 ml). All of the devices were set to infuse at 10 ml · h(-1) at room temperature (21°C) for 12 h. The fluid delivered during each 2-h period was measured using a graduated column. The On-Q pump (in the settings of normal fill and 150% overfill) delivered a significantly higher output per hour than the set rate during the first 8 h, while the Ambu pump delivered a value close to the set rate of 10 ml · h(-1). No significant difference in the hourly delivered output was noted for either device when comparing the normal fill to the 150% overfill groups. This investigation demonstrates that no change in the hourly output occurs with overfilling of these home infusion devices. However, as noted previously, the hourly output from the On-Q device is significantly higher than the set rate during the initial 8 h of infusion which could have potential clinical implications. © 2016 John Wiley & Sons Ltd.

  5. Insulin compatibility with polymer materials used in external pump infusion systems.

    Science.gov (United States)

    Melberg, S G; Havelund, S; Villumsen, J; Brange, J

    1988-04-01

    In a study designed to mimic actual user conditions for external insulin pump infusion, the insulin quality after passage through the infusion set was assessed by various analytical methods, including high performance liquid chromatography. The two infusion sets tested consisted of, firstly, a polyvinylchloride/rubber syringe and a polyvinylchloride catheter sterilized by gamma irradiation and, secondly, a polyethylene/polypropylene syringe connected to a polyethylene catheter and sterilized by ethylene oxide. The insulin solution delivered through the PVC infusion set showed a reduction of preservative to less than 30% of the initial content and increased formation of chemical transformation products of insulin varying from twice the reference level during the first day to more than three times on the third day. By contrast, the polyethylene/polypropylene infusion system showed only a minor decrease in preservative content and no increase in chemical transformation. These effects were observed irrespective of the brand of insulin and were not affected by increase of the zinc content of the insulin solution. Investigation of the influence of the sterilization methods performed on polyvinylchloride and polyethylene catheters revealed that gamma irradiated polyvinylchloride catheters were markedly harmful to the insulin solution, whereas ethylene oxide sterilization did not influence the chemical stability of insulin.

  6. Protocol for a randomised crossover trial to evaluate patient and nurse satisfaction with electronic and elastomeric portable infusion pumps for the continuous administration of antibiotic therapy in the home: the Comparing Home Infusion Devices (CHID) study.

    Science.gov (United States)

    Hobbs, Jodie G; Ryan, Melissa K; Ritchie, Brett; Sluggett, Janet K; Sluggett, Andrew J; Ralton, Lucy; Reynolds, Karen J

    2017-07-31

    Previous studies comparing satisfaction with electronic and elastomeric infusion pumps are limited, and improvements in size and usability of electronic pumps have since occurred. The Comparing Home Infusion Devices (CHID) study plans to assess patient and nurse satisfaction with an elastomeric and electronic pump for delivering intravenous antibiotic treatment in the home. Secondary objectives are to determine pump-related complications and actual antibiotic dose administered, evaluate temperature variation and compare pump operating costs. The CHID study will be a randomised, crossover trial. A trained research nurse will recruit patients with infectious disease aged ≥18 years and prescribed ≥8 days of continuous intravenous antibiotic therapy from the Royal Adelaide Hospital (RAH) (Adelaide, Australia). Patients will be randomised to receive treatment at home via an elastomeric (Baxter Infusor) or an electronic (ambIT Continuous) infusion pump for 4-7 days, followed by the other for a further 4-7 days. Patient satisfaction will be assessed by a 10-item survey to be completed at the end of each arm. Nurse satisfaction will be assessed by a single 24-item survey. Patient logbooks and case notes from clinic visits will be screened to identify complications. Pumps/infusion bags will be weighed to estimate the volume of solution delivered. Temperature sensors will record skin and ambient temperatures during storage and use of the pumps throughout the infusion period. Costs relating to pumps, consumables, antibiotics and servicing will be determined. Descriptive statistics will summarise study data. This study has been approved by the RAH Human Research Ethics Committee (HREC/16/RAH/133 R20160420, version 6.0, 5 September 2016). Study results will be disseminated through peer-reviewed publications and conference presentations. The CHID study will provide key insights into patient and provider satisfaction with elastomeric and electronic infusion pumps and inform

  7. Understanding Infusion Pumps.

    Science.gov (United States)

    Mandel, Jeff E

    2018-04-01

    Infusion systems are complicated electromechanical systems that are used to deliver anesthetic drugs with moderate precision. Four types of systems are described-gravity feed, in-line piston, peristaltic, and syringe. These systems are subject to a number of failure modes-occlusion, disconnection, siphoning, infiltration, and air bubbles. The relative advantages of the various systems and some of the monitoring capabilities are discussed. A brief example of the use of an infusion system during anesthetic induction is presented. With understanding of the functioning of these systems, users may develop greater comfort.

  8. Methods for studying medical device technology and practitioner cognition: the case of user-interface issues with infusion pumps.

    Science.gov (United States)

    Schraagen, Jan Maarten; Verhoeven, Fenne

    2013-02-01

    The aims of this study were to investigate how a variety of research methods is commonly employed to study technology and practitioner cognition. User-interface issues with infusion pumps were selected as a case because of its relevance to patient safety. Starting from a Cognitive Systems Engineering perspective, we developed an Impact Flow Diagram showing the relationship of computer technology, cognition, practitioner behavior, and system failure in the area of medical infusion devices. We subsequently conducted a systematic literature review on user-interface issues with infusion pumps, categorized the studies in terms of methods employed, and noted the usability problems found with particular methods. Next, we assigned usability problems and related methods to the levels in the Impact Flow Diagram. Most study methods used to find user interface issues with infusion pumps focused on observable behavior rather than on how artifacts shape cognition and collaboration. A concerted and theory-driven application of these methods when testing infusion pumps is lacking in the literature. Detailed analysis of one case study provided an illustration of how to apply the Impact Flow Diagram, as well as how the scope of analysis may be broadened to include organizational and regulatory factors. Research methods to uncover use problems with technology may be used in many ways, with many different foci. We advocate the adoption of an Impact Flow Diagram perspective rather than merely focusing on usability issues in isolation. Truly advancing patient safety requires the systematic adoption of a systems perspective viewing people and technology as an ensemble, also in the design of medical device technology. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Bomba de infusão de insulina em diabetes melito tipo 1 Insulin pump therapy in type 1 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Raphael Del Roio Liberatore Jr.

    2006-08-01

    Full Text Available OBJETIVO: Rever a experiência com a utilização da bomba de infusão de insulina em crianças e adolescentes, a fim de orientar o pediatra quanto às suas indicações e complicações. FONTE DOS DADOS : Foi realizada revisão sistemática de artigos publicados em literatura que abordassem a utilização da bomba de infusão de insulina, suas indicações, complicações e resposta ao tratamento. Dessa forma, todos os artigos publicados entre 1995 e 2005 foram resgatados através do levantamento em banco de dados MEDLINE e LILACS. As palavras-chave utilizadas foram: insulin pumps, type 1 diabetes mellitus e diabetes mellitus. Foram separados os artigos que, além disso, versassem sobre o assunto na faixa etária descrita SÍNTESE DOS DADOS: O uso da bomba de infusão de insulina em pacientes com diabetes melito tipo 1 não é uma necessidade para todos os pacientes, visto que, com tratamentos intensivos, os resultados conseguidos são muito parecidos, em termos de hemoglobina glicada e de controle de complicações a médio e longo prazo. No entanto, a bomba permite um maior conforto ao paciente, no sentido de que ele não precisa ficar tão restrito a horários rígidos de refeição e pode levar uma vida com melhor qualidade. Um primeiro requisito para quem pretenda usar a bomba é adaptar-se a aparelhos conectados ao corpo e a ter uma rotina de monitorização glicêmica rigorosa, pois, sem isso, as vantagens da bomba serão anuladas. As complicações, com os avanços tecnológicos de que dispomos atualmente, são muito infreqüentes. O custo, no entanto, é maior que nos tratamentos convencionais. CONCLUSÃO: Com a evolução das bombas de infusão e dos monitores de glicemia, incluindo sistemas de monitorização contínua, abre-se caminho para as "bombas inteligentes", e estaremos com um verdadeiro "pâncreas artificial", que pode mesmo ser implantado no paciente, permitindo uma vida com todas as regalias de uma pessoa não diab

  10. Effects of atmospheric pressure conditions on flow rate of an elastomeric infusion pump.

    Science.gov (United States)

    Wang, Jong; Moeller, Anna; Ding, Yuanpang Samuel

    2012-04-01

    The effects of pressure conditions, both hyperbaric and hypobaric, on the flow rate of an elastomeric infusion pump were investigated. The altered pressure conditions were tested with the restrictor outlet at two different conditions: (1) at the same pressure condition as the Infusor elastomeric balloon and (2) with the outlet exposed to ambient conditions. Five different pressure conditions were tested. These included ambient pressure (98-101 kilopascals [kPa]) and test pressures controlled to be 10 or 20 kPa below or 75 or 150 kPa above the ambient pressure. A theoretical calculation based on the principles of fluid mechanics was also used to predict the pump's flow rate at various ambient conditions. The conditions in which the Infusor elastomeric pump and restrictor outlet were at the same pressure gave rise to average flow rates within the ±10% tolerance of the calculated target flow rate of 11 mL/hr. The flow rate of the Infusor pump decreased when the pressure conditions changed from hypobaric to ambient. The flow rate increased when the pressure conditions changed from hyperbaric to ambient. The flow rate of the Infusor elastomeric pump was not affected when the balloon reservoir and restrictor outlet were at the same pressure. The flow rate varied from 58.54% to 377.04% of the labeled flow rate when the pressure applied to the reservoir varied from 20 kPa below to 150 kPa above the pressure applied to the restrictor outlet, respectively. The maximum difference between observed flow rates and those calculated by applying fluid mechanics was 4.9%.

  11. [A Quantitative Verification for Operability of Three PCA Devices Attached to the Disposable Infusion Pumps].

    Science.gov (United States)

    Tadokoro, Takahiro; Fuchibe, Makoto; Odo, Yuichiro; Kakinohana, Manabu

    2015-11-01

    In this study using 3 different PCA devices (Baxter infuser LVBB +PCM 2 ml: Pump B, Coopdech Balloonjector +PCA 3 ml: Pump C, Rakuraku fuser +PCA 3 ml: Pump S), we investigated how easily PCA devices could be handled. In this study with 42 volunteers (14 elders and 28 nurses), we compared 3 PCA ejection volume and ejection rate among three PCA devices. PCA ejection rate was defined as the ratio of actual ejection volume to the maximum ejection volume (MEV) of each PCA device. Although not only elders but also nurses failed to produce accurate PCA ejection volume in the Pump B, Pump S could provide the MEV even by elders. In the Pump C, approximately 80% of MEV could be achieved by nurses, but 60% of MEV by elders (P PCA ejection volume might be dependent on PCA device.

  12. Optimization of intelligent infusion pump technology to minimize vasopressor pump programming errors.

    Science.gov (United States)

    Vadiei, Nina; Shuman, Carrie A; Murthy, Manasa S; Daley, Mitchell J

    2017-08-01

    There is a lack of data evaluating the impact of hard limit implementation into intelligent infusion pump technology (IIPT). The purpose of this study was to determine if incorporation of vasopressor upper hard limits (UHL) into IIPT increases efficacy of alerts by preventing pump programming errors. Retrospective review from five hospitals within a single healthcare network between April 1, 2013 and May 31, 2014. A total of 65,680 vasopressor data entries were evaluated; 19,377 prior to hard limit implementation and 46,303 after hard limit implementation. The primary outcome was the percent of effective alerts. The secondary outcome was the proportional dose increase from the soft limit provided. A reduction in alert rate occurred after incorporation of hard limits to the IIPT drug library (pre-UHL 4.7% vs. post-UHL 4.0%) with a subsequent increase in the number of errors prevented as represented by a higher effective alert rate (pre-UHL 23.0% vs. post-UHL 37.3%; p < 0.001). The proportional dose increase was significantly reduced (pre-UHL 188% ± 380%] vs. post-UHL 95% ± 128%; p < 0.001). Incorporation of UHLs into IIPT in a multi-site health system with varying intensive care unit and emergency department acuity increases alert effectiveness, reduces dosing errors, and reduces the magnitude of dosing errors that reach the patient.

  13. Infusion volume control and calculation using metronome and drop counter based intravenous infusion therapy helper.

    Science.gov (United States)

    Park, Kyungnam; Lee, Jangyoung; Kim, Soo-Young; Kim, Jinwoo; Kim, Insoo; Choi, Seung Pill; Jeong, Sikyung; Hong, Sungyoup

    2013-06-01

    This study assessed the method of fluid infusion control using an IntraVenous Infusion Controller (IVIC). Four methods of infusion control (dial flow controller, IV set without correction, IV set with correction and IVIC correction) were used to measure the volume of each technique at two infusion rates. The infused fluid volume with a dial flow controller was significantly larger than other methods. The infused fluid volume was significantly smaller with an IV set without correction over time. Regarding the concordance correlation coefficient (CCC) of infused fluid volume in relation to a target volume, IVIC correction was shown to have the highest level of agreement. The flow rate measured in check mode showed a good agreement with the volume of collected fluid after passing through the IV system. Thus, an IVIC could assist in providing an accurate infusion control. © 2013 Wiley Publishing Asia Pty Ltd.

  14. A web-based study of the relationship of duration of insulin pump infusion set use and fasting blood glucose level in adults with type 1 diabetes.

    Science.gov (United States)

    Sampson Perrin, Alysa J; Guzzetta, Russell C; Miller, Kellee M; Foster, Nicole C; Lee, Anna; Lee, Joyce M; Block, Jennifer M; Beck, Roy W

    2015-05-01

    To evaluate the impact of infusion set use duration on glycemic control, we conducted an Internet-based study using the T1D Exchange's online patient community, Glu ( myGlu.org ). For 14 days, 243 electronically consented adults with type 1 diabetes (T1D) entered online that day's fasting blood glucose (FBG) level, the prior day's total daily insulin (TDI) dose, and whether the infusion set was changed. Mean duration of infusion set use was 3.0 days. Mean FBG level was higher with each successive day of infusion set use, increasing from 126 mg/dL on Day 1 to 133 mg/dL on Day 3 to 147 mg/dL on Day 5 (P<0.001). TDI dose did not vary with increased duration of infusion set use. Internet-based data collection was used to rapidly conduct the study at low cost. The results indicate that FBG levels increase with each additional day of insulin pump infusion set use.

  15. Adequate plasma drug concentrations suggest that amoxicillin can be administered by continuous infusion using elastomeric pumps.

    Science.gov (United States)

    Arensdorff, Lyne; Boillat-Blanco, Noémie; Decosterd, Laurent; Buclin, Thierry; de Vallière, Serge

    2017-09-01

    Elastomeric pumps can be useful for the administration of antibiotics in the outpatient setting. To determine amoxicillin degradation in elastomeric pumps, as well as the effectiveness of amoxicillin treatment administered by elastomeric pumps. Antibiotic degradation was measured in elastomeric pumps filled with 6 g of amoxicillin in 240 mL of NaCl 0.9% by drawing samples at 12 h intervals when stored in the fridge for 48 h and when worn around the waist for 24 h. Subsequently nine patients were treated with continuous infusions of 8 or 12 g of amoxicillin per day. Plasma amoxicillin concentrations were measured on each visit to the outpatient parenteral antibiotic therapy unit. Clinical outcome was verified 3 months after the end of treatment. Amoxicillin degradation in elastomeric pumps reached 10% after 48 h in the fridge and an additional 30% when worn around the waist for 24 h. Mean plasma drug concentrations achieved with 12 g of amoxicillin per day were 18.5 mg/L (95% CI 13.5-23.5), which is largely above the MIC of amoxicillin-susceptible bacteria. Nine patients treated for various complicated infections were cured and had no unexpected adverse effects. Adequate plasma drug concentrations and favourable clinical outcomes suggest that amoxicillin can be administered by continuous infusion using elastomeric pumps. This treatment modality does not fulfil formal requirements regarding pharmaceutical stability, but the resulting safety impact in patients is probably limited. Therapeutic drug monitoring and a close clinical follow-up are recommended if this route of administration is chosen. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature.

    Science.gov (United States)

    Wilson, Ana Maria Miranda Martins; Peterlini, Maria Angélica Sorgini; Pedreira, Mavilde da Luz Gonçalves

    2016-08-15

    to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies. identificar na literatura a produção científica acerca dos efeitos de bomba de infusão na administração de hemácias e avaliar as implicações do uso desses equipamentos na prática transfusional de enfermagem. revisão integrativa de literatura nas bases de dados Pubmed/Medline, Scopus, Biblioteca Virtual em Saúde, SciELO, Web of Science e Cochrane, utilizando os descritores "bombas de infusão", "transfusão de sangue", "transfusão de eritrócitos" e "hemólise". A data inicial não foi delimitada e a final foi dezembro de

  17. Catheter Migration After Implantationan Intrathecal Baclofen Infusion Pump for Severe Spasticity: A Case Report

    Directory of Open Access Journals (Sweden)

    Tung-Chou Li

    2008-09-01

    Full Text Available We report a case of intrathecal baclofen infusion pump implantation complicated by migration of the catheter tip. A 55-year-old man required an intrathecal baclofen infusion for severe spasticity 4 years after a cervical spinal cord injury with incomplete tetraparesis. Twelve months after initial implantation of the device, the patient began to experience a recurrence of trunk tightness and spasticity. Subsequent X-ray and computed tomography evaluations of the catheter system revealed pooling of contrast medium outside of the intrathecal distribution in the lumbar subcutaneous region of the back and therefore migration of the pump catheter tip. At surgical revision, emphasis was placed on minimizing the length of catheter outside of the spine and securing the catheter in the supraspinous fascia with a right-angled anchor. The distance between the anchors and the entry point of the catheter into the supraspinous fascia was also reduced to prevent slipping when the patient bends forward. After surgery, the patient's spasticity improved and, 1 year later, he has experienced no further complications during follow-up, requiring an average baclofen dose of 150 mg/day. Here, we describe several surgical methods intended to secure the intrathecal catheter and prevent catheter migration. Other complications related to catheter failure are also highlighted.

  18. A comparison of two nuclear-medical techniques for effective renal plasma flow determination in rabbits: Radiation controlled infusion-pump and whole-body measurement according to Oberhausen

    International Nuclear Information System (INIS)

    Mayer-Wehrstein, R.

    1981-01-01

    Two nuclear techniques were investigated for determination of the effective renal plasma flow with J-131-Hippuran in rabbits: whole-body measurement according to Oberhausen and clearance determination with a radiation controlled feed back infusion pump. In the first method the clearance determination follows after a single injection of the testing substance in the decreasing phase of the blood level, in the second method a constant blood level of the testing substance is maintained. A technique was developed for the determination of the blood-tissue ratio by considering the values determined by the constant blood level. This way the exact clearance values were computet for the decreasing plasma level. Nineteen clearance determinations were performed in rabbits altogether. (orig.) [de

  19. Combining situated Cognitive Engineering with a novel testing method in a case study comparing two infusion pump interfaces

    NARCIS (Netherlands)

    Schnittker, R.; Schmettow, M.; Verhoeven, F.; Schraagen, J.M.C.

    2016-01-01

    We validated the usability of a new infusion pump interface designed with a situated Cognitive Engineering approach by comparing it to a reference interface using a novel testing method employing repeated measurements and process measures, in addition to traditional outcome measures. The sample

  20. Using higher doses to compensate for tubing residuals in extended-infusion piperacillin-tazobactam.

    Science.gov (United States)

    Lam, Wendy J; Bhowmick, Tanaya; Gross, Alan; Vanschooneveld, Trevor C; Weinstein, Melvin P

    2013-06-01

    To mathematically assess drug losses due to infusion line residuals and evaluate methods to compensate for drug loss due to residual volumes in intravenous pump tubing. Literature was accessed through Ovid MEDLINE (1996-February 2013), using combinations of the search terms tubing residuals, residual volume, residual medication, intravenous infusions, intravenous injections, piperacillin, piperacillin-tazobactam, β-lactams, equipment design, infusion pumps, extended infusion, extended administration, and prolonged infusion. In addition, select reference citations from publications identified were reviewed. All articles that involved extended-infusion piperacillin-tazobactam implementation strategies were included in the review. Infusion pump characteristics and tubing residuals can affect extended-infusion piperacillin-tazobactam dosing strategies. Two studies addressing tubing residuals were identified. Both studies recommended increasing infusion volumes to compensate for tubing residuals. One study also recommended decreasing infusion-line dead space by using alternative infusion pump systems. Study calculations suggest that higher doses of piperacillin-tazobactam may be used to account for medication left in tubing residuals if alternative infusion pump systems cannot be obtained, and increased infusion volumes are not an option. Extended-infusion piperacillin-tazobactam has been used as a method of maximizing pharmacodynamic target attainment. Use of higher doses of piperacillin-tazobactam may be a reasonable method to compensate for drug loss due to residual volumes in large-bore intravenous pump tubing.

  1. Continuous intraperitoneal insulin infusion in patients with 'brittle' diabetes

    DEFF Research Database (Denmark)

    DeVries, J H; Eskes, S A; Snoek, Frank J

    2002-01-01

    AIMS: To evaluate the effects of continuous intraperitoneal insulin infusion (CIPII) using implantable pumps on glycaemic control and duration of hospital stay in poorly controlled 'brittle' Dutch diabetes patients, and to assess their current quality of life. METHODS: Thirty-three patients were...

  2. Methods for studying medical device technology and practitioner cognition : The case of user-interface issues with infusion pumps

    NARCIS (Netherlands)

    Schraagen, J.M.C.; Verhoeven, F.

    2013-01-01

    Purpose : The aims of this study were to investigate how a variety of research methods is commonly employed to study technology and practitioner cognition. User-interface issues with infusion pumps were selected as a case because of its relevance to patient safety. Methods : Starting from a

  3. Baxter elastomeric pumps: Feasibility of weight estimates.

    Science.gov (United States)

    Chambers, Carole R; Pabia, Mica; Sawyer, Michael; Tang, Patricia A

    2017-09-01

    Purpose Elastomeric pumps are used to infuse a 46-h fluorouracil protocol and patients are asked to visually inspect the pump daily. The pump has a variability of ±10% and there are additional patient variables that can increase this. The feasibility of weighing the pump rather than a visual inspection along with the secondary objective to confirm the pump's variability in real world conditions was undertaken. Methods Empty pumps were weighed using both pharmacy and kitchen scales. Pumps upon completion of the 46-h infusion were also weighed using both pharmacy and kitchen scales. Results The kitchen scale was as accurate as the pharmacy grade scale. Disconnected pumps showed the expected variability from using these infusor pumps along with a few showing greater variability likely due to patient variables. Conclusion Weighing pumps appears to be feasible both at the pharmacy and home level. Next steps would be to weigh pumps during the infusion to validate an alternate method to simple visual inspection for patients to confirm proper infusing of the pump at their home.

  4. The History of Target-Controlled Infusion

    NARCIS (Netherlands)

    Struys, Michel M. R. F.; De Smet, Tom; Glen, John (Iain) B.; Vereecke, Hugo E. M.; Absalom, Anthony R.; Schnider, Thomas W.

    Target-controlled infusion (TCI) is a technique of infusing IV drugs to achieve a user-defined predicted (target) drug concentration in a specific body compartment or tissue of interest. In this review, we describe the pharmacokinetic principles of TCI, the development of TCI systems, and technical

  5. Rocuronium: automatic infusion versus manual administration with TOF monitorisation.

    Science.gov (United States)

    Ozturk Arikan, Fatma Gulcin; Turan, Guldem; Ozgultekin, Asu; Sivrikaya, Zubeyir; Cosar, Bekir Cem; Onder, Dondu Nisa

    2016-10-01

    TOF (train-of-four) monitoring provides objective data in application of neuromuscular blocking agent. Thus, applicator-based differences are eliminated and optimum muscle relaxation is maintained during operation. In the present study, we aimed to compare the effects of target-controlled infusion system and standard TOF monitoring, on use of rocuronium. ASA I-II patients, who were aged between 18 and 75 years and scheduled for elective abdominal surgery at Haydarpaşa Numune Training and Research Hospital, were enrolled in the study. In order to evaluate neuromuscular blockade, the patients in Group 1 were connected to the acceleromyography device of the target-controlled infusion pump (Veryark-CLMRIS-I-China) while the ones in Group 2 were connected to the routinely used acceleromyography device (TOF Watch SX). There was no significant difference between groups regarding patient characteristics, the durations of anaesthesia and surgery, quality of intubation, time to extubation and time to recovery (TOF ratio of 0.9). Intubation time was significantly longer in Group 1 (Automated group) as compared to Group 2 (Control group) (p rocuronium amount used in Group 1 was found to be significantly higher than the amount used in Group 2 (p rocuronium was administered via automatical infusion pump during anaesthesia.

  6. The Efficacy of Postoperative Wound Infusion with Bupivacaine for Pain Control after Cesarean Delivery: Randomized Double Blind Clinical Trial

    Directory of Open Access Journals (Sweden)

    Azin Alavi

    2007-06-01

    Full Text Available Objective: This study investigated the efficacy of bupivacaine wound infusion for pain control and opioid sparing effect after cesarean delivery.Materials and methods: We conducted a randomized double blind, placebo controlled clinical trial on 60 parturients undergoing cesarean section at a university hospital in Tehran. Patients were randomized to receive a pump infusion system that was filled with either 0.25% bupivacaine or equal volume of distilled water. A catheter was placed above the fascia and connected to electronic pump for 24 hours. Postoperative analog pain scores and morphine consumption were assessed at 6, 12 and 24 hours. Also time interval to first ambulation, length of hospitalization, complications and patient satisfaction were recorded. Data were analyzed using the SPSS software and P < 0.05 was considered statistically significant. Mann-Whitney u-test, student t-test and chi-square were used. Results: There were no differences in patient demographics and length of hospitalization and patient-generated resting pain scores between the two groups. Pain scores after coughing and leg raise during the first 6 postoperative hours were significantly less in the Bupivacaine group (P<0.001. The total dose of morphine consumption during the 24 hours study period was 2.5 ± 2.5 mg vs. 7.3 ± 2.7 mg for the bupivacaine and control groups, respectively (P<0.001. Compared with the control group, time to first ambulation was shorter in the bupivacaine group (11± 5h vs. 16 ± 4h (P< 0.01. Conclusion: Bupivacaine wound infusion was a simple and safe technique that provides effective analgesia and reduces morphine requirements after cesarean delivery.

  7. The properties of an improvised piston pump for the rapid delivery of intravenous fluids.

    Science.gov (United States)

    Smart, C M; Primrose, C W; Peters, A L; Speirits, E J

    2014-02-01

    To maximise the effect of a small fluid load, it is occasionally desirable to bolus manually with multiple depressions of a large-capacity syringe. This is usually achieved by placing the syringe on the side port of a three-way tap. We modified this technique by placing two-one-way valves in line with the three-way tap, effectively creating a piston pump, the infusion rates via which we compared with those achieved by an inflatable pressure-infuser in a simulated resuscitation. Fluid flow was faster using the piston pump than with the pressure-infuser (mean (SD) time to infuse 2000 ml saline 0.9% via a 16-G cannula 352 (10) s vs 495 (19) s, respectively, p piston pump appears to have potential for both tight control of fluid delivery and major high-volume resuscitation. The lightweight nature of the pump and its lack of reliance on gravity may also make it suitable for the pre-hospital setting. © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  8. Advancing medication infusion safety through the clinical integration of technology.

    Science.gov (United States)

    Gerhart, Donald; O'Shea, Kristen; Muller, Sharon

    2013-01-01

    Adverse drug events resulting from errors in prescribing or administering medications are preventable. Within a hospital system, numerous technologies are employed to address the common sources of medication error, including the use of electronic medical records, physician order entry, smart infusion pumps, and barcode medication administration systems. Infusion safety is inherently risky because of the high-risk medications administered and the lack of integration among the stand-alone systems in most institutions. Intravenous clinical integration (IVCI) is a technology that connects electronic medical records, physician order entry, smart infusion pumps, and barcode medication administration systems. It combines the safety features of an automatically programmed infusion pump (drug, concentration, infusion rate, and patient weight, all auto-programmed into the device) with software that provides visibility to real-time clinical infusion data. Our article describes the characteristics of IVCI at WellSpan Health and its impact on patient safety. The integrated infusion system has the capability of reducing medication errors, improving patient care, reducing in-facility costs, and supporting asset management. It can enhance continuous quality improvement efforts and efficiency of clinical work flow. After implementing IVCI, the institution realized a safer patient environment and a more streamlined work flow for pharmacy and nursing.

  9. Infusion of radionuclides throughout pregnancy

    International Nuclear Information System (INIS)

    Mountford-Lister, P.G.; Lambert, B.E.; Milner, A.C.; Kang, X.Z.

    1992-01-01

    This work is part of a long-term study to examine the cancer incidence in the offspring of mice exposed to 239 Pu or 147 Pm throughout pregnancy. The need to model the human intake scenario and the possibility of a critical period during uterine development necessitates constant availability of radionuclides throughout pregnancy. Various methods (multiple daily injections, infusion by external cannula and infusion by indwelling osmotic pump) have been examined and osmotic infusion pumps chosen. These pumps result in a near-constant blood concentration for up to 21 days. Part of the study is the estimation of dose to the critical haemopoietic tissues of the pup from a knowledge of the radionuclide distribution and kinetics. At present the distribution has been followed from birth to 180 days. Activity in the suckling pups at 7 days old is around 1 percent of the infused activity, though most of this is accounted for by the contents of the stomach and gastrointestinal tract. The liver and femur account for around 0.025 percent and 0.012 percent respectively per pup. Activity increases in both liver and femur during lactation after which both concentration and activity fall with time. Long-term studies with the pups of dams exposed to a range of 239 Pu concentrations between 0-70 kBq/kg are underway. Correlation of average organ dose with tumour incidence will be determined at completion of the life-span study. (Author) 39 refs., 5 tabs., 6 figs

  10. The efficacy of a lidocaine-infused pain pump for postoperative analgesia following elective augmentation mammaplasty or abdominoplasty.

    Science.gov (United States)

    Chavez-Abraham, Victor; Barr, Jason S; Zwiebel, Paul C

    2011-08-01

    Postoperative pain management following aesthetic plastic surgery traditionally has been achieved by systemic administration of several narcotic pain medications. Because this method can lead to undesirable side effects such as sedation, nausea, vomiting, and respiratory depression, a more efficacious method of postoperative analgesia with fewer side effects needs to be implemented in outpatient cosmetic surgery. From March of 2003 until December of 2008, 690 patients underwent augmentation mammaplasty and 215 patients underwent abdominoplasty. All of these patients were equipped with an elastomeric continuous infusion pump postoperatively and were prescribed oral narcotics. Prior to 2003, patients were prescribed only oral narcotics postoperatively. A retrospective chart review of patients before and after implementation of the pain pump was undertaken to review the perceived pain patients experienced postoperatively with and without the pump. The self-administration of oral narcotics was also assessed. Patients equipped with the pain pump experienced a statistically significant decrease in perceived pain compared to those without the pump (augmentation mammaplasty: 2.27 vs. 3.68, p use of the oral narcotic Vicodin™ at 72 h postoperatively (5 mg hydrocodone/500 mg acetaminophen, Abbott Laboratories, Abbott Park, IL) (augmentation mammaplasty: 26.5 mg/2650 mg vs. 49 mg/4900 mg, p reduce both the amount of pain patients experience and the quantity of narcotics used postoperatively.

  11. A New Approach in the Design of High-Risk Infusion Technology

    Directory of Open Access Journals (Sweden)

    Robert Murphy

    2010-01-01

    Full Text Available The syringe infusion pump has been established as the instrument of choice for high-risk infusions, where potent drugs are often delivered at low rates of flow. However, numerous instances of unexpected flow error with consequent patient physiological impact have been reported. These include unwanted bolus delivery on release of line occlusion, dosage fluctuation due to pump height change and fluid reflux within the multiple pump installations now common in the Intensive Care Unit (ICU. This article examines the performance of a typical ICU syringe infusion pump and identifies mechanical compliance, inherent in commercial designs, as a source of flow error that should not be ignored by equipment designers. A prototype low compliance system is described and tested with performance compared to the conventional design, demonstrating advantages in terms of lower flow error.

  12. Effect of continuous subcutaneous insulin pump infusion on glucolipid metabolism as well as inflammation and oxidative stress in placenta of patients with GDM

    Directory of Open Access Journals (Sweden)

    Liu Jie

    2017-05-01

    Full Text Available Objective: To study the effect of continuous subcutaneous insulin pump infusion on glucolipid metabolism as well as inflammation and oxidative stress in placenta of patients with gestational diabetes mellitus (GDM. Methods: Patients with GDM who received insulin therapy between March 2013 and May 2016 were selected as the research subjects and randomly divided into multiple subcutaneous insulin injection (MSII group and continuous subcutaneous insulin pump infusion (CSII group. Before and after treatment, serum glucolipid metabolism as well as inflammation and oxidative stress inexes in placenta were determined respectively. Results: 2 weeks and 4 weeks after treatment, FBG, 1hPBG, 2hPBG, Chemerin, Vaspin and Visfatin levels of both groups of patients were significantly lower than those before treatment and FBG, 1hPBG, 2hPBG, Chemerin, Vaspin and Visfatin levels of CSII group were significantly lower than those of MSII group; after delivery, TNF-α, IL-6, ROS and AGEs levels in placenta of CSII group were significantly lower than those of MSII group. Conclusion: Continuous subcutaneous insulin infusion can more effectively improve the glucolipid metabolism and inhibit the inflammation and oxidative stress in placenta of patients with GDM than multiple subcutaneous insulin injection.

  13. Continuous infusion of chemotherapy: focus on 5-fluorouracil and fluorodeoxyuridine

    NARCIS (Netherlands)

    Poorter, R. L.; Bakker, P. J.; Veenhof, C. H.

    1998-01-01

    Continuous infusion of chemotherapy is one of the developments to try to improve the treatment of metastatic cancer. There is a sound theoretical rationale to deliver cytotoxic drugs as a continuous infusion. Furthermore, the development of reliable venous access devices and portable infusion pumps

  14. D-Zero HVAC Heat Pump Controls

    International Nuclear Information System (INIS)

    Markley, Dan

    2004-01-01

    This engineering note documents the integration of Dzero Heat Pump 1 through Heat Pump 15 into the cryo/gas process control system commonly referred to as the cryo control system. Heat pumps 1 through 15 control the ambient air temperature on the 3rd, 5th, and 6th floor office areas at Dzero. The entire Johnson HVAC control system was replaced with a Siemens control system in 1999 leaving behind the 15 heat pumps with stand-alone Johnson controllers. Now, these 15 heat pump Johnson controllers are being replaced with small stand alone Beckhoff BC9000 controllers. The Beckhoff BC9000 controllers are network able into the existing Intellution control system. The Beckhoff BC9000 controllers use the cryo private Ethernet network and an OPC driver to get data into the Intellution SCADA node databases. The BC9000 is also programmed over this same Ethernet network.

  15. Prediction of Bispectral Index during Target-controlled Infusion of Propofol and Remifentanil: A Deep Learning Approach.

    Science.gov (United States)

    Lee, Hyung-Chul; Ryu, Ho-Geol; Chung, Eun-Jin; Jung, Chul-Woo

    2018-03-01

    The discrepancy between predicted effect-site concentration and measured bispectral index is problematic during intravenous anesthesia with target-controlled infusion of propofol and remifentanil. We hypothesized that bispectral index during total intravenous anesthesia would be more accurately predicted by a deep learning approach. Long short-term memory and the feed-forward neural network were sequenced to simulate the pharmacokinetic and pharmacodynamic parts of an empirical model, respectively, to predict intraoperative bispectral index during combined use of propofol and remifentanil. Inputs of long short-term memory were infusion histories of propofol and remifentanil, which were retrieved from target-controlled infusion pumps for 1,800 s at 10-s intervals. Inputs of the feed-forward network were the outputs of long short-term memory and demographic data such as age, sex, weight, and height. The final output of the feed-forward network was the bispectral index. The performance of bispectral index prediction was compared between the deep learning model and previously reported response surface model. The model hyperparameters comprised 8 memory cells in the long short-term memory layer and 16 nodes in the hidden layer of the feed-forward network. The model training and testing were performed with separate data sets of 131 and 100 cases. The concordance correlation coefficient (95% CI) were 0.561 (0.560 to 0.562) in the deep learning model, which was significantly larger than that in the response surface model (0.265 [0.263 to 0.266], P deep learning model-predicted bispectral index during target-controlled infusion of propofol and remifentanil more accurately compared to the traditional model. The deep learning approach in anesthetic pharmacology seems promising because of its excellent performance and extensibility.

  16. A remotely operated, automated system for the infusion of shielded therapeutic radiopharmaceuticals

    International Nuclear Information System (INIS)

    Macfarlane, D.J.; Bartlett, M.; Bellen, J.; Peters, J.; Domagala, M.; Allison, R.

    1999-01-01

    Full text: A number of radiopharmaceuticals may soon emerge into mainstream clinical oncology for palliative and therapeutic treatment for a variety of malignancies. These agents are characterized by high linear energy transfer particulate emissions. Dispensing and administration of these therapies on a regular basis pose a substantial radiation burden to staff, from direct g-emissions and from Bremsstrahlung (braking) radiations. In an effort to implement the ALARA principle, a multidisciplinary team was given the brief to design a system which permitted: (1) safe, sterile transfer of a nominated quantity of radiopharmaceutical into a shielded reservoir compatible with the infusion pump; (2) remote variation of volume and administration rate upon command; (3) purging of delivery system following administration of dose; (4) monitoring of and communication with patient during infusion; (5) use of TGA-approved delivery system. The final design centred around an Abbott 'Lifecare 5000' volumetric dual-channel intravenous infusion pump and featured: microprocessor control with mutiline LCD prompting display; remote operation of keypad by pneumatic actuator; CCTV monitoring of patient, pump and physiological data; delivery of therapy dose from a shielded vial; flushing of therapy vial by 'back-priming'; and full array of safety alarms (air in line, occlusion, empty vial, etc). Further developments include audio communication with patient and remote physiological monitoring

  17. Respiratory failure following delayed intrathecal morphine pump refill: a valuable, but costly lesson.

    Science.gov (United States)

    Ruan, Xiulu; Couch, J Patrick; Liu, HaiNan; Shah, Rinoo V; Wang, Frank; Chiravuri, Srinivas

    2010-01-01

    Spinal analgesia, mediated by opioid receptors, requires only a fraction of the opioid dose that is needed systemically. By infusing a small amount of opioid into the cerebrospinal fluid in close proximity to the receptor sites in the spinal cord, profound analgesia may be achieved while sparing some of the side effects due to systemic opioids. Intraspinal drug delivery (IDD) has been increasingly used in patients with intractable chronic pain, when these patients have developed untoward side effects with systemic opioid usage. The introduction of intrathecal opioids has been considered one of the most important breakthroughs in pain management in the past three decades. A variety of side effects associated with the long-term usage of IDD have been recognized. Among them, respiratory depression is the most feared. To describe a severe adverse event, i.e., respiratory failure, following delayed intrathecal morphine pump refill. A 65-year-old woman with intractable chronic low back pain, due to degenerative disc disease, and was referred to our clinic for an intraspinal drug delivery evaluation, after failing to respond to multidisciplinary pain treatment. Following a psychological evaluation confirming her candidacy, she underwent an outpatient patient-controlled continuous epidural morphine infusion trial. The infusion trial lasted 12 days and was beneficial in controlling her pain. The patient reported more than 90% pain reduction with improved distance for ambulation. She subsequently consented and was scheduled for permanent intrathecal morphine pump implantation. The intrathecal catheter was inserted at right paramedian L3-L4, with catheter tip advanced to L1, confirmed under fluoroscopy. Intrathecal catheter placement was confirmed by positive CSF flow and by myelogram. A non-programmable Codman 3000 constant-flow rate infusion pump was placed in the right mid quandrant between right rib cage and right iliac crest. The intrathecal infusion consisted of

  18. Skin regeneration in deep second-degree scald injuries either by infusion pumping or topical application of recombinant human erythropoietin gel

    Directory of Open Access Journals (Sweden)

    Giri P

    2015-05-01

    Full Text Available Priya Giri,1 Sabine Ebert,1 Ulf-Dietrich Braumann,2 Mathias Kremer,3 Shibashish Giri,1 Hans-Günther Machens,4 Augustinus Bader1 1Department of Cell Techniques and Applied Stem Cell Biology, Center for Biotechnology and Biomedicine (BBZ, Faculty of Medicine, University of Leipzig, Leipzig, Germany; 2Interdisciplinary Center for Bioinformatics (IZBI, University of Leipzig, Leipzig, Germany; 3Department of Plastic and Hand Surgery, University of Lübeck, Lübeck, Germany; 4Department of Plastic and Hand Surgery, Technical University of Munich, Munich, Germany Abstract: Large doses of recombinant growth factors formulated in solution form directly injected into the body is usual clinical practice in treating second-degree scald injuries, with promising results, but this approach creates side effects; furthermore, it may not allow appropriate levels of the factor to be sensed by the target injured tissue/organ in the specific time frame, owing to complications arising from regeneration. In this research, two delivery methods (infusion pumping and local topical application were applied to deliver recombinant human erythropoietin (rHuEPO for skin regeneration. First, rHuEPO was given in deep second-degree scald injury sites in mice by infusion pump. Vascularization was remarkably higher in the rHuEPO pumping group than in controls. Second, local topical application of rHuEPO gel was given in deep second-degree scald injury sites in rats. Histological analysis showed that epithelialization rate was significantly higher in the rHuEPO gel-treated group than in controls. Immunohistochemical studies showed that the rHuEPO gel-treated group showed remarkably higher expression of skin regeneration makers than the control group. An accurate method for visualization and quantification of blood vessel networks in target areas has still not been developed up to this point, because of technical difficulties in detecting such thin blood vessels. A method which

  19. Absorption of subcutaneously infused insulin: influence of the basal rate pulse interval.

    Science.gov (United States)

    Hildebrandt, P; Birch, K; Jensen, B M; Kühl, C; Brange, J

    1985-01-01

    Eight insulin-dependent diabetic patients were given two constant infusions (each 1 IU/h) of 125I-labeled insulin into the abdominal subcutaneous tissue for about 12 h. Insulin was infused in pulses into one side of the abdomen in 6-min intervals (by means of an Auto-Syringe pump) and in the other side of the abdomen, insulin was infused in 1-h intervals (by means of a Medix pump). The size of the subcutaneous depots was continuously measured by counting the radioactivity at the infusion sites. After starting the infusions, the two depots were built up to steady-state levels at the same time and of the same size (approximately 3 IU) and with similar absorption rates. Thus, during basal rate insulin infusion, identical insulin absorption kinetics was achieved, irrespective of a 10-fold difference in the pulse rate.

  20. Designing the modern pump: engineering aspects of continuous subcutaneous insulin infusion software.

    Science.gov (United States)

    Welsh, John B; Vargas, Steven; Williams, Gary; Moberg, Sheldon

    2010-06-01

    Insulin delivery systems attracted the efforts of biological, mechanical, electrical, and software engineers well before they were commercially viable. The introduction of the first commercial insulin pump in 1983 represents an enduring milestone in the history of diabetes management. Since then, pumps have become much more than motorized syringes and have assumed a central role in diabetes management by housing data on insulin delivery and glucose readings, assisting in bolus estimation, and interfacing smoothly with humans and compatible devices. Ensuring the integrity of the embedded software that controls these devices is critical to patient safety and regulatory compliance. As pumps and related devices evolve, software engineers will face challenges and opportunities in designing pumps that are safe, reliable, and feature-rich. The pumps and related systems must also satisfy end users, healthcare providers, and regulatory authorities. In particular, pumps that are combined with glucose sensors and appropriate algorithms will provide the basis for increasingly safe and precise automated insulin delivery-essential steps to developing a fully closed-loop system.

  1. Krypton 81m infusion studies. Chapter 18

    International Nuclear Information System (INIS)

    Kaplan, E.; Mayron, L.W.; Friedman, A.M.; Gindler, J.E.

    1978-01-01

    A technique is described to give a continuous, constant-rate, intravascular infusion of 81 Krsup(m). Modifications of earlier generators included production of sodium-free 81 Rb, the use of a solution of commercial sterile isotonic non-ionic 5% dextrose-in-water as an eluant, the incorporation of a constant-rate infusion pump, and the miniaturization of the generator column and catheter system. Results are presented of studies of 81 Krsup(m) distribution in dogs, using both intravenous and intra-arterial infusion. (author)

  2. [The use of continuous subcutaneous insulin infusion (CSII) with personal insulin pumps in the treatment of children and adolescents with diabetes type 1].

    Science.gov (United States)

    Jarosz-Chobot, Przemysława

    2004-01-01

    This paper sums up recently published researches on the continuous subcutaneous insulin infusion (CSII) with the use of insulin pump in children and adolescents with diabetes type 1. Obtaining a balance in the organism metabolism in childhood and adolescence diabetology is nowadays one of the most important rules of the diabetes management in children. One of the modern ways to achieve that goal is the intensive insulin therapy model with use of the insulin pump. In this paper the advantages and disadvantages as well as the indications and contraindications for the CSII in children and adolescents with diabetes are widely discussed.

  3. Anomalies in target-controlled infusion: an analysis after 20 years of clinical use.

    Science.gov (United States)

    Engbers, F H M; Dahan, A

    2018-05-01

    Although target-controlled infusion has been in use for more than two decades, its benefits are being obscured by anomalies in clinical practice caused by a number of important problems. These include: a variety of pharmacokinetic models available in open target-controlled infusion systems, which often confuse the user; the extrapolation of anthropomorphic data which provokes anomalous adjustments of dosing by such systems; and the uncertainty of regulatory requirements for the application of target-controlled infusion which causes uncontrolled exploitation of drugs and pharmacokinetic models in target-controlled infusion devices. Comparison of performance of pharmacokinetic models is complex and mostly inconclusive. However, a specific behaviour of a model in a target-controlled infusion system that is neither intended nor supported by scientific data can be considered an artefact or anomaly. Several of these anomalies can be identified in the current commercially available target-controlled infusion systems and are discussed in this review. © 2018 The Association of Anaesthetists of Great Britain and Ireland.

  4. Infusion MR arteriography during hepatic arterial infusion chemotherapy. Evaluation of clinical usefulness

    International Nuclear Information System (INIS)

    Uchino, Minako; Takizawa, Kenji

    2003-01-01

    We developed a new method of infusion MR arteriography (IMRA) via an implantable port system using an infusion pump for the evaluation of drug distribution during hepatic arterial infusion chemotherapy. The purposes of this study were to optimize the method and evaluate its clinical usefulness. We used 3D-T1 turbo field echo (TFE) as the most suitable sequence for IMRA according to the results of a phantom model experiment. We examined 33 cases of liver cancer that had been treated by arterial infusion chemotherapy via the port system. The following investigations were performed: degree of tumor enhancement, intra- and extra- hepatic perfusion abnormality, and related toxicity. The evaluation of images was performed separately by two radiologists. IMRA provided good images of contrast enhancement, to reveal the perfusion patterns. The treatment response rate in the tumor group with well enhancement was higher than that of the group with poor enhancement (p<0.0001). Extrahepatic perfusion was well visualized and was correlated with toxicity (p<0.0001). IMRA is a useful method to evaluate drug perfusion for the optimization of arterial infusion chemotherapy. (author)

  5. Hepatic artery infusion (HAI) for hepatic metastases in combination with hepatic resection and hepatic radiation

    International Nuclear Information System (INIS)

    Merrick, H.W.; Dobelbower, R.R.; Ringleint, J.F.; Skeel, R.T.

    1986-01-01

    Renewed interest in hepatic artery infusion has been stimulated by the development of a totally implantable pump which eliminates many of the problems encountered by the external pumps and catheters. As the potential benefit of hepatic artery infusion would be greater if either all gross disease were removed by prior resection, or alternatively, if non-resectable disease were irradiated in conjunction with hepatic artery infusion, the authors initiated a phase I-II trial to evaluate combined modality therapy

  6. Control Law Design for Propofol Infusion to Regulate Depth of Hypnosis: A Nonlinear Control Strategy

    Directory of Open Access Journals (Sweden)

    Ali Khaqan

    2016-01-01

    Full Text Available Maintaining the depth of hypnosis (DOH during surgery is one of the major objectives of anesthesia infusion system. Continuous administration of Propofol infusion during surgical procedures is essential but increases the undue load of an anesthetist in operating room working in a multitasking setup. Manual and target controlled infusion (TCI systems are not good at handling instabilities like blood pressure changes and heart rate variability arising due to interpatient variability. Patient safety, large interindividual variability, and less postoperative effects are the main factors to motivate automation in anesthesia. The idea of automated system for Propofol infusion excites the control engineers to come up with a more sophisticated and safe system that handles optimum delivery of drug during surgery and avoids postoperative effects. In contrast to most of the investigations with linear control strategies, the originality of this research work lies in employing a nonlinear control technique, backstepping, to track the desired hypnosis level of patients during surgery. This effort is envisioned to unleash the true capabilities of this nonlinear control technique for anesthesia systems used today in biomedical field. The working of the designed controller is studied on the real dataset of five patients undergoing surgery. The controller tracks the desired hypnosis level within the acceptable range for surgery.

  7. Dextrose boluses versus burette dextrose infusions in prevention of ...

    African Journals Online (AJOL)

    Background: Hypoglycemia is a major cause of morbidity and mortality among preterm infants and its management remains a challenge in resource limited settings. Use of dextrose infusion by the recommended infusion pumps is not feasible in our environment due to their high costs and yet the current use of mini dextrose ...

  8. [External lumbar drainage with volumetric continuing infusion pump in patients with cerebrospinal fluid leak. A case series].

    Science.gov (United States)

    Manso Melgosa, Ana Belén; García Gutiérrez, Helena; Fernández Porras, Mónica; Castrillo Manero, Ana Berta; Pérez Marijuán, Belén

    To describe the incidence and complications arising in a number of cases of patients with cerebrospinal fluid leak treated by external lumbar drainage with infusion pump (IP) volumetric continuous from 2001 to 2014. Quantify cerebrospinal fluid leak closed by lumbar drainage with IP. Retrospective descriptive case series study. patients undergoing transsphenoidal pituitary surgery, Chiari surgery and laminectomy, that developed postoperative cerebrospinal fluid leak treated with continuous external lumbar drainage by IP. age, sex, type of intervention, variables related to the practice of the pump and complications. Average and medians were calculated for quantitative variables, frequencies and percentages for qualitative. Sample: 11 subjects. Incidence in running IP: disconnection, occlusion and acoustic alarm activation. Most frequently complication is headache; a case of pneumocephalus. The small number of subjects and the heterogeneity of these do not allow for comparison or establishing associations between variables. The resolution of the cerebrospinal fluid leak with continuous IP is lower in this study than others, and may be influenced by the small number of subjects. It should be noted the frequent activation of the pump alarm for no apparent cause. Protocol would be developed for preparing the IP team to reduce the acoustic alarm activation, and would make a prospective multicenter study. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  9. Angiotensin II-induced hypertension increases plasma membrane Na pump activity by enhancing Na entry in rat thick ascending limbs.

    Science.gov (United States)

    Gonzalez-Vicente, Agustin; Garvin, Jeffrey L

    2013-11-01

    Thick ascending limbs (TAL) reabsorb 30% of the filtered NaCl load. Na enters the cells via apical Na-K-2Cl cotransporters and Na/H exchangers and exits via basolateral Na pumps. Chronic angiotensin II (ANG II) infusion increases net TAL Na transport and Na apical entry; however, little is known about its effects on the basolateral Na pump. We hypothesized that in rat TALs Na pump activity is enhanced by ANG II-infusion, a model of ANG II-induced hypertension. Rats were infused with 200 ng·kg(-1)·min(-1) ANG II or vehicle for 7 days, and TAL suspensions were obtained. We studied plasma membrane Na pump activity by measuring changes in 1) intracellular Na (Nai) induced by ouabain; and 2) ouabain-sensitive oxygen consumption (QO2). We found that the ouabain-sensitive rise in Nai in TALs from ANG II-infused rats was 12.8 ± 0.4 arbitrary fluorescent units (AFU)·mg(-1)·min(-1) compared with only 9.9 ± 1.1 AFU·mg(-1)·min(-1) in controls (P Na pump expression, the number of Na pumps in the plasma membrane, or the affinity for Na. When furosemide (1.1 mg·kg(-1)·day(-1)) was coinfused with ANG II, no increase in plasma membrane Na pump activity was observed. We concluded that in ANG II-induced hypertension Na pump activity is increased in the plasma membrane of TALs and that this increase is caused by the chronically enhanced Na entry occurring in this model.

  10. Fuzzy multivariable control of domestic heat pumps

    International Nuclear Information System (INIS)

    Underwood, C.P.

    2015-01-01

    Poor control has been identified as one of the reasons why recent field trials of domestic heat pumps in the UK have produced disappointing results. Most of the technology in use today uses a thermostatically-controlled fixed speed compressor with a mechanical expansion device. This article investigates improved control of these heat pumps through the design and evaluation of a new multivariable fuzzy logic control system utilising a variable speed compressor drive with capacity control linked through to evaporator superheat control. A new dynamic thermal model of a domestic heat pump validated using experimental data forms the basis of the work. The proposed control system is evaluated using median and extreme daily heating demand profiles for a typical UK house compared with a basic thermostatically-controlled alternative. Results show good tracking of the heating temperature and superheat control variables, reduced cycling and an improvement in performance averaging 20%. - Highlights: • A new dynamic model of a domestic heat pump is developed and validated. • A new multivariable fuzzy logic heat pump control system is developed/reported. • The fuzzy controller regulates both plant capacity and evaporator superheat degree. • Thermal buffer storage is also considered as well as compressor cycling. • The new controller shows good variable tracking and a reduction in energy of 20%.

  11. Pump integrated closed loop control. The intelligent actuator pump - state of the art and perspectives; Pumpenintegrierte Prozessregelung. Der intelligente Aktor Pumpe - Stand und Moeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, Thomas; Schullerer, Joachim; Oesterle, Manfred [KSB AG, Frankenthal (Germany)

    2009-07-01

    In many areas of industrial automation, centrifugal pumps and systems of centrifugal pumps are important actuators of a process und therefore a fundamental part of the entire plant. In contrary to the controlled valves, located behind the pump in the pipework system, the functions of the intelligent actuator pump or system of pumps are rarely used and noticed. With regard to the reduction of life cycle costs of the asset pump, pump integrated closed loop control of the fluid transport task has advantages over central closed loop control e.g. in a process control system. This article contains a survey of the intelligent actuator pump, its structure and functions with regard to the solution of the fluid transport task and according pump integrated closed loop control. (orig.)

  12. Effect of nitrous oxide on cisatracurium infusion demands: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Illman Hanna L

    2010-08-01

    Full Text Available Abstract Background Recent studies have questioned our previous understanding on the effect of nitrous oxide on muscle relaxants, since nitrous oxide has been shown to potentiate the action of bolus doses of mivacurium, rocuronium and vecuronium. This study was aimed to investigate the possible effect of nitrous oxide on the infusion requirements of cisatracurium. Methods 70 ASA physical status I-III patients aged 18-75 years were enrolled in this randomized trial. The patients were undergoing elective surgery requiring general anesthesia with a duration of at least 90 minutes. Patients were randomized to receive propofol and remifentanil by target controlled infusion in combination with either a mixture of oxygen and nitrous oxide (Nitrous oxide/TIVA group or oxygen in air (Air/TIVA group. A 0.1 mg/kg initial bolus of cisatracurium was administered before tracheal intubation, followed by a closed-loop computer controlled infusion of cisatracurium to produce and maintain a 90% neuromuscular block. Cumulative dose requirements of cisatracurium during the 90-min study period after bolus administration were measured and the asymptotic steady state rate of infusion to produce a constant 90% block was determined by applying nonlinear curve fitting to the data on the cumulative dose requirement during the study period. Results Controller performance, i.e. the ability of the controller to maintain neuromuscular block constant at the setpoint and patient characteristics were similar in both groups. The administration of nitrous oxide did not affect cisatracurium infusion requirements. The mean steady-state rates of infusion were 0.072 +/- 0.018 and 0.066 +/- 0.017 mg * kg-1 * h-1 in Air/TIVA and Nitrous oxide/TIVA groups, respectively. Conclusions Nitrous oxide does not affect the infusion requirements of cisatracurium. Trial registration ClinicalTrials.gov NCT01152905; European Clinical Trials Database at http://eudract.emea.eu.int/2006-006037-41.

  13. Standpipe-bubbler pump level control study: 1E-3862, controlled clearance pump/system Model W. P. 7373. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    Computer simulation results of the standpipe-bubbler pump level control system/controlled clearance pump configuration 1E-3862 using specific plan elevations are presented. Fluid level control system behavior is presented in graphical form for normal plant loading, unloading, and trip transients. Satisfactory fluid level control can be attained for this configuration with a standpipe-bubbler system.

  14. PLC-Based Pressure Control in Multi-Pump Applications

    Directory of Open Access Journals (Sweden)

    Vodovozov Valery

    2015-12-01

    Full Text Available The paper is devoted to the centrifugal pumps represented the most popular type of pumping equipment used in different areas. The pressure control approach for variable speed driven (VSD parallel connected centrifugal pumps is reported. The goal of the study is optimization of some quality indices, such as efficiency, consumed power, productivity, energy carrier temperature, heat irradiation, etc. One of them – efficiency – has been studied in the paper more carefully. The mathematical model of pumping process is discussed and a vector-matrix description of the multi-pump application is given. The program-based pressure control system is developed which productivity is changed by regulating the number of working pumps. The paper introduces new pressure control algorithms based on the working point estimation intended for programmable logical controllers (PLC. Experiments prove correctness of the offered methodology.

  15. Radical resection for low rectal carcinoma combined with infusion pump chemotherapy via internal iliac artery

    Directory of Open Access Journals (Sweden)

    Bo YANG

    2011-10-01

    Full Text Available Objective To evaluate the effects and practicability of radical resection for low rectal carcinoma with infusion pump chemotherapy via internal iliac artery,and explore the correlation factors influencing the therapeutic effects.Methods Data of 316 patients with low rectal carcinoma,admitted from Oct.1997 to Mar.2008,were retrospectively analyzed and assigned into 2 groups according to the treatment: Patients received infusion pump chemotherapy via internal iliac artery to target area combined with intravenous systemic chemotherapy were assigned into group A(n=249,and those receiving systemic chemotherapy alone following radical resection were assigned to group B(n=67.The timing of pump chemotherapy to target area in group A was set at day 12 after recovery of digestive function,with regimen of 5-FU at 0.5g per dose plus hydroxycamptothecin at 10-15mg per dose,twice a week,four times as a treatment course for a total of 6 courses,and it was followed by intravenously systemic chemotherapy with a regimen of FOLFIRI or FOLFOX.In group B,at day 12 right after recovery of digestive function,the intravenous sytemic chemotherapy was started with the same regimen as in group A.The local recurrence rate,metastasis rate and survival rate after 1,3 and 5 years in the two groups were respectively observed and compared,and the correlation between the clinicopathological features and the 5 year local recurrence rates and survival rates was analyzed in patients of group A.Results In group A,the local recurrence rate at year 1,3 and 5 was 0,1.68%(4/238 and 3.79%(8/211,respectively,the metastasis rate was 0.80%(2/249,4.62%(11/238 and 10.90%(23/211,respectively,and the survival rate was 100%,77.73%(185/238 and 72.04%(152/211,respectively.In group B,the local recurrence rate at year 1,3 and 5 was 0,9.52%(6/63 and 16.36%(9/55,respectively,the metastasis rate was 1.49%(1/67,15.87%(10/63 and 27.27%(15/55,respectively,and the survival rate was 100

  16. LH2 three-phase pump control circuit description

    International Nuclear Information System (INIS)

    Pierce, W.

    1977-05-01

    A brief description and circuit drawings are given for a pump control system. The pump is used to circulate liquid hydrogen through the cell and heat exchanger of an LH 2 target. The pump is powered by three-phase 60 cycle power, and the control unit is powered from a positive and negative 24 V dc supply available in the NIM Bin. The control unit is packaged in a double-width NIM module. Drawings are given for the pump speed indicator, function generator, and power supply

  17. Liquid metal flow control by DC electromagnetic pumps

    International Nuclear Information System (INIS)

    Borges, Eduardo Madeira; Braz Filho, Francisco Antonio; Guimaraes, Lamartine Nogueira Frutuoso

    2006-01-01

    The cooling system of high-density thermal power requires fluids of high thermal conductivity, such as liquid metals. Electromagnetic pumps can be used to liquid metal fluid flow control in cooling circuits. The operation of electromagnetic pumps used to flow control is based on Lorentz force. This force can be achieved by magnetic field and electric current interaction, controlled by external independent power supplies. This work presents the electromagnetic pump operational principles, the IEAv development scheme and the BEMC-1 simulation code. The theoretical results of BEMC-1 simulation are compared to electromagnetic pump operation experimental data, validating the BEMC-1 code. This code is used to evaluate the DC electromagnetic pump performance applied to Mercury flow control and others liquid metal such as Sodium, Lead and Bismuth, used in nuclear fast reactors. (author)

  18. Energy Efficient Pump Control for an Offshore Oil Processing System

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Soleiman, Kian; Løhndorf, Bo

    2012-01-01

    The energy efficient control of a pump system for an offshore oil processing system is investigated. The seawater is lifted up by a pump system which consists of three identical centrifugal pumps in parallel, and the lifted seawater is used to cool down the crude oil flowing out of a threephase...... separator on one of the Danish north-sea platform. A hierarchical pump-speed control strategy is developed for the considered system by minimizing the pump power consumption subject to keeping a satisfactory system performance. The proposed control strategy consists of online estimation of some system...... operating parameters, optimization of pump configurations, and a real-time feedback control. Comparing with the current control strategy at the considered system, where the pump system is on/off controlled, and the seawater flows are controlled by a number of control valves, the proposed control strategy...

  19. Regulating vacuum pump speed with feedback control

    International Nuclear Information System (INIS)

    Ludington, D.C.; Aneshansley, D.J.; Pellerin, R.; Guo, F.

    1992-01-01

    Considerable energy is wasted by the vacuum pump/motor on dairy farms. The output capacity (m 3 /min or cfm) of the vacuum pump always exceeds the capacity needed to milk cows and wash pipelines. Vacuum pumps run at full speed and load regardless of actual need for air. Excess air is admitted through a controller. Energy can be saved from electrical demand reduced by regulating vacuum pump speed according to air based on air usage. An adjustable speed drive (ASD) on the motor and controlled based upon air usage, can reduce the energy used by the vacuum pump. However, the ASD unit tested could not maintain vacuum levels within generally accepted guidelines when air usage changed. Adding a high vacuum reserve and a dual vacuum controller between the vacuum pump and the milking pipeline brought vacuum stability within guidelines. The ASD/dual vacuum system can reduce energy consumption and demand by at least 50 percent during milking and provide better vacuum stability than conventional systems. Tests were not run during washing cycles. Using 1990 costs and only the energy saved during milking, the simple payback on investment in new equipment for a 5 hp motor, speed controller and vacuum regulator would be about 5 years

  20. Effect of different dosages of nitroglycerin infusion on arterial blood gas tensions in patients undergoing on- pump coronary artery bypass graft surgery.

    Science.gov (United States)

    Masoumi, Gholamreza; Pour, Evaz Hidar; Sadeghpour, Ali; Ziayeefard, Mohsen; Alavi, Mostapha; Anbardan, Sanam Javid; Shirani, Shahin

    2012-02-01

    On-pump coronary artery bypass graft (CABG) surgery impairs gas exchange in the early postoperative period. The main object on this study was evaluation of changes in arterial blood gas values in patients underwent on pump CABG surgery receiving different dose of intravenous nitroglycerin (NTG). sixty-seven consecutive patients undergoing elective on-pump CABG randomly enrolled into three groups receiving NTG 50 μg/min (Group N1, n =67), 100 μg/min (Group N2, n = 67), and 150 μg/min (Group N3, n = 67). Arterial blood gas (ABG) tensions were evaluated just before induction of anesthesia, during anesthesia, at the end of warming up period, and 6 h after admission to the intensive care unit. Pao2 and PH had the highest value during surgery in Group N1, Group N2, and Group N3. No significant difference was noted in mean values of Pao2 and PH during surgery between three groups (P > 0.05). There was no significant difference in HCO3 values in different time intervals among three groups (P > 0.05). our results showed that infusing three different dosage of NTG (50, 100, and 150 μg/min) had no significant effect on ABG tensions in patients underwent on-pump CABG surgery.

  1. Economic benefits of improved insulin stability in insulin pumps.

    Science.gov (United States)

    Weiss, Richard C; van Amerongen, Derek; Bazalo, Gary; Aagren, Mark; Bouchard, Jonathan R

    2011-05-01

    Insulin pump users discard unused medication and infusion sets according to labeling and manufacturer's instructions. The stability labeling for insulin aspart (rDNA origin] (Novolog) was increased from two days to six. The associated savings was modeled from the perspective of a hypothetical one-million member health plan and the total United States population. The discarded insulin volume and the number of infusion sets used under a two-day stability scenario versus six were modeled. A mix of insulin pumps of various reservoir capacities with a range of daily insulin dosages was used. Average daily insulin dose was 65 units ranging from 10 to 150 units. Costs of discarded insulin aspart [rDNA origin] were calculated using WAC (Average Wholesale Price minus 16.67%). The cost of pump supplies was computed for the two-day scenario assuming a complete infusion set change, including reservoirs, every two days. Under the six-day scenario complete infusion sets were discarded every six days while cannulas at the insertion site were changed midway between complete changes. AWP of least expensive supplies was used to compute their costs. For the hypothetical health plan (1,182 pump users) the annual reduction in discarded insulin volume between scenarios was 19.8 million units. The corresponding cost reduction for the plan due to drug and supply savings was $3.4 million. From the U.S. population perspective, savings of over $1 billion were estimated. Using insulin that is stable for six days in pump reservoirs can yield substantial savings to health plans and other payers, including patients.

  2. Online feedback-controlled renal constant infusion clearances in rats.

    Science.gov (United States)

    Schock-Kusch, Daniel; Shulhevich, Yury; Xie, Qing; Hesser, Juergen; Stsepankou, Dzmitry; Neudecker, Sabine; Friedemann, Jochen; Koenig, Stefan; Heinrich, Ralf; Hoecklin, Friederike; Pill, Johannes; Gretz, Norbert

    2012-08-01

    Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique.

  3. Model-based drug administration : current status of target-controlled infusion and closed-loop control

    NARCIS (Netherlands)

    Kuizenga, Merel H.; Vereecke, Hugo E. M.; Struys, Michel M. R. F.

    Purpose of review Drug administration might be optimized by incorporating pharmacokinetic-dynamic (PK/PD) principles and control engineering theories. This review gives an update of the actual status of target-controlled infusion (TCI) and closed-loop computer-controlled drug administration and the

  4. Absorption Cycle Heat Pump Model for Control Design

    DEFF Research Database (Denmark)

    Vinther, Kasper; Just Nielsen, Rene; Nielsen, Kirsten Mølgaard

    2015-01-01

    Heat pumps have recently received increasing interest due to green energy initiatives and increasing energy prices. In this paper, a nonlinear dynamic model of a single-effect LiBr-water absorption cycle heat pump is derived for simulation and control design purposes. The model is based on an act......Heat pumps have recently received increasing interest due to green energy initiatives and increasing energy prices. In this paper, a nonlinear dynamic model of a single-effect LiBr-water absorption cycle heat pump is derived for simulation and control design purposes. The model is based...... to operational data and different scenarios are simulated to investigate the operational stability of the heat pump. Finally, this paper provides suggestions and examples of derivation of lower order linear models for control design. © Copyright IEEE - All rights reserved....

  5. Insulin pump therapy in children with type 1 diabetes

    DEFF Research Database (Denmark)

    Szypowska, Agnieszka; Schwandt, Anke; Svensson, Jannet

    2016-01-01

    BACKGROUND: Intensified insulin delivery using multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) is recommended in children with type 1 diabetes (T1D) to achieve good metabolic control. OBJECTIVE: To examine the frequency of pump usage in T1D children treated...... in SWEET (Better control in Paediatric and Adolescent diabeteS: Working to crEate CEnTers of Reference) centers and to compare metabolic control between patients treated with CSII vs MDI. METHODS: This study included 16 570 T1D children participating in the SWEET prospective, multicenter, standardized...... is offered by most Sweet centers. The differences between centers affect the frequency of use of modern technology. Despite the heterogeneity of centers, T1D children achieve relatively good metabolic control, especially those treated with insulin pumps and those of younger age....

  6. Home Healthcare Medical Devices: Infusion Therapy - Getting the Most Out of Your Pump

    Science.gov (United States)

    ... Medical Procedures Home Health and Consumer Devices Brochure - Home Healthcare Medical Devices: Infusion Therapy - Getting the Most ... if needed. What is the role of your home healthcare provider and supplier in your infusion therapy? ...

  7. [How to promote the respect of good infusion practices by meeting health care professionals?].

    Science.gov (United States)

    Le Reste, C; Fiedler, A; Dubois, S; Dewailly, A; Le Du, I; Cogulet, V

    2016-05-01

    Health care professionals often forget that there are risks associated with infusion therapy even if it is a common care. In order to assess this practice and to draw potential improvement actions, an audit of local gravity-flow intravenous infusion practices was conducted. The audit, based on a grid including 66 items from the medical prescription to the end of the infusion therapy administration, was conducted in the 6 units which use the most gravity-flow intravenous infusion devices. A multidisciplinary working group was created to decide and organize priority corrective measures in order to improve infusion practices and quality of healthcare. The audit enabled to observe 90hours of nurse's practices (96 infusions) and highlighted heterogeneity in infusion, in some cases inappropriate infusion practices and misuse of infusion devices. We found 4 main issues: labelling infusion therapy, training of health care professionals on good practices, support the purchase of infusion pumps and standardize perfusion line. An interactive educational program for nurses (workshops) was organized to enhance the respect of good practices: infusion identification at any time, respect of hygiene rules, flow rate regulation by counting drops, appropriate use of pumps and flow rate regulators. The audit drew up work priorities. The workshops made easier exchanges between professionals and had a warm welcome that's why it is essential to carry on such training. This collaborative approach between pharmacists, nurses, hygienists and biomedical technicians contribute to drug management improvement and promote optimal patient care. Copyright © 2015 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  8. Chronic intrastriatal dopamine infusions in rats with unilateral lesions of the substantia nigra

    International Nuclear Information System (INIS)

    Hargraves, R.; Freed, W.J.

    1987-01-01

    This study examined the effects of continuously supplied dopamine delivered directly into the dopamine-deficient striatum. Rats received unilateral lesions of the substantia nigra by stereotaxic administration of 6-hydroxydopamine and were tested for apomorphine-induced rotational behavior and general activity. Osmotic mini-pumps were filled with dopamine in various concentrations, implanted subcutaneously and connected to a cannula implanted directly into the striatum. The system delivered solution at a rate of .5 μl/hr for two weeks. Dopamine in a dosage of 0.5 μg/per hour reduced apomorphine-induced rotational behavior by a mean of 52 +/- 5.8% (mean +/- SEM n=20) with a maximal individual decrease of 99%. There was no change in general activity or increase in stereotype behavior. Infusions of vehicle solutions did not decrease rotational behavior. Spread of the infused dopamine and its metabolites was estimated by adding 3 H-dopamine to the pumps in tracer quantities. Radioactivity was highly concentrated at the infusion site and decreased rapidly within a few mm from the infusion site. Continuous infusion methods may eventually prove to be effective in the treatment of nigro-striatal degenerative disease. 12 references, 4 figures

  9. Method for controlling powertrain pumps

    Science.gov (United States)

    Sime, Karl Andrew; Spohn, Brian L; Demirovic, Besim; Martini, Ryan D; Miller, Jean Marie

    2013-10-22

    A method of controlling a pump supplying a fluid to a transmission includes sensing a requested power and an excess power for a powertrain. The requested power substantially meets the needs of the powertrain, while the excess power is not part of the requested power. The method includes sensing a triggering condition in response to the ability to convert the excess power into heat in the transmission, and determining that an operating temperature of the transmission is below a maximum. The method also includes determining a calibrated baseline and a dissipation command for the pump. The calibrated baseline command is configured to supply the fluid based upon the requested power, and the dissipation command is configured to supply additional fluid and consume the excess power with the pump. The method operates the pump at a combined command, which is equal to the calibrated baseline command plus the dissipation command.

  10. Controlling groundwater pumping online.

    Science.gov (United States)

    Zekri, Slim

    2009-08-01

    Groundwater over-pumping is a major problem in several countries around the globe. Since controlling groundwater pumping through water flow meters is hardly feasible, the surrogate is to control electricity usage. This paper presents a framework to restrict groundwater pumping by implementing an annual individual electricity quota without interfering with the electricity pricing policy. The system could be monitored online through prepaid electricity meters. This provides low transaction costs of individual monitoring of users compared to the prohibitive costs of water flow metering and monitoring. The public groundwater managers' intervention is thus required to determine the water and electricity quota and watch the electricity use online. The proposed framework opens the door to the establishment of formal groundwater markets among users at very low transaction costs. A cost-benefit analysis over a 25-year period is used to evaluate the cost of non-action and compare it to the prepaid electricity quota framework in the Batinah coastal area of Oman. Results show that the damage cost to the community, if no active policy is implemented, amounts to (-$288) million. On the other hand, the implementation of a prepaid electricity quota with an online management system would result in a net present benefit of $199 million.

  11. Increasing the use of 'smart' pump drug libraries by nurses: a continuous quality improvement project.

    Science.gov (United States)

    Harding, Andrew D

    2012-01-01

    The use of infusion pumps that incorporate "smart" technology (smart pumps) can reduce the risks associated with receiving IV therapies. Smart pump technology incorporates safeguards such as a list of high-alert medications, soft and hard dosage limits, and a drug library that can be tailored to specific patient care areas. Its use can help to improve patient safety and to avoid potentially catastrophic harm associated with medication errors. But when one independent community hospital in Massachusetts switched from older mechanical pumps to smart pumps, it neglected to assign an "owner" to oversee the implementation process. One result was that nurses were using the smart pump library for only 37% of all infusions.To increase pump library usage percentage-thereby reducing the risks associated with infusion and improving patient safety-the hospital undertook a continuous quality improvement project over a four-month period in 2009. With the involvement of direct care nurses, and using quantitative data available from the smart pump software, the nursing quality and pharmacy quality teams identified ways to improve pump and pump library use. A secondary goal was to calculate the hospital's return on investment for the purchase of the smart pumps. Several interventions were developed and, on the first of each month, implemented. By the end of the project, pump library usage had nearly doubled; and the hospital had completely recouped its initial investment.

  12. Assessment of use of specific features of subcutaneous insulin infusion systems and their relationship to metabolic control in patients with type 1 diabetes.

    Science.gov (United States)

    Quirós, Carmen; Patrascioiu, Ioana; Giménez, Marga; Vinagre, Irene; Vidal, Mercè; Jansà, Margarita; Conget, Ignacio

    2014-01-01

    Patients with type 1 diabetes (T1DM) treated with continuous subcutaneous insulin infusion (CSII) have available several specific features of these devices. The aim of this study was to evaluate the relationship between real use of them and the degree of glycemic control in patients using this therapy. Forty-four T1DM patients on CSII therapy with or without real-time continuous glucose monitoring (CGM) were included. Data from 14 consecutive days were retrospectively collected using the therapy management software CareLink Personal/Pro(®) and HbA1c measurement performed at that period. The relationship between the frequency of usie of specific features of insulin pumps (non-sensor augmented or sensor-augmented) and glycemic control was analyzed. Mean HbA1c in the group was 7.5 ± .8%. Mean daily number of boluses administered was 5.1 ± 1.8, with 75.4% of them being bolus wizards (BW). Daily number of boluses was significantly greater in patients with HbA1c 7.5% (5.3 ± 1.6 vs. 4.3 ± 1.6, P=.056). There was a trend to greater use of BW in patients with better control (82.8 ± 21.4% vs. 69.9 ± 29.1%, P=.106). HbA1c was lower in patients using CGM (n=8) as compared to those not using sensor-augmented pumps (7.6 ± .8 vs 7.1 ± .7, P=.067), but the difference was not statistically significant. More frequent use of BW appears to be associated to better metabolic control in patients with T1DM using pump therapy. In standard clinical practice, augmentation of insulin pump with CGM may be associated to improved glycemic control. Copyright © 2013 SEEN. Published by Elsevier Espana. All rights reserved.

  13. Aggregated Control of Domestic Heat Pumps

    DEFF Research Database (Denmark)

    Nielsen, Kirsten M.; Andersen, Palle; Pedersen, Tom S.

    2013-01-01

    A challenge in Denmark in the near future is to balance the electrical grid due to a large increase in the renewable energy production mainly from wind turbines. In this work an aggregated control system using heat pumps in single family houses to help balancing the grid is investigated....... The control system is able to adjust the consumptions of the heat pump without affecting the comfort in the houses and uses this ability to shift the total consumption to hours with high wind energy production....

  14. Continuous Drug Infusion for Diabetes Therapy: A Closed-Loop Control System Design

    Directory of Open Access Journals (Sweden)

    Jiming Chen

    2008-03-01

    Full Text Available While a typical way for diabetes therapy is discrete insulin infusion based on long-time interval measurement, in this paper, we design a closed-loop control system for continuous drug infusion to improve the traditional discrete methods and make diabetes therapy automatic in practice. By exploring the accumulative function of drug to insulin, a continuous injection model is proposed. Based on this model, proportional-integral-derivative (PID and fuzzy logic controllers are designed to tackle a control problem of the resulting highly nonlinear plant. Even with serious disturbance of glucose, such as nutrition absorption at meal time, the proposed scheme can perform well in simulation experiments.

  15. Using Variable Speed Control on Pump Application

    Directory of Open Access Journals (Sweden)

    Dr.Sc. Aida Spahiu

    2012-06-01

    Full Text Available Pumps are one of the most common variable speed drive (VSD system applications and special interest has focused on improving their energy efficiency by using variable speed control instead of throttling or other less efficient flow control methods. Pumps are the single largest user of electricity in industry in the European Union, consuming 160 TWh per annum of electricity and accounting for 79 million tonnes of carbon dioxide (CO2 emissions [1]. Centrifugal pumps are the most likely pump style to provide a favorable return based on energy savings when applied with a variable speed drive. To help illustrate this, are conducted benchmark testing to document various head and flow scenarios and their corresponding effect on energy savings. Paper shows the relationship of static and friction head in the energy efficiency equation and the effect of motor, pump and VSD efficiencies. The received results are good reference points for engineers and managers of water sector in Albania to select the best prospects for maximizing efficiency and energy savings.

  16. Insulin Pump Malfunction During Hospitalization: Two Case Reports.

    Science.gov (United States)

    Faulds, Eileen R; Wyne, Kathleen L; Buschur, Elizabeth O; McDaniel, Jodi; Dungan, Kathleen

    2016-06-01

    Insulin pump malfunctions and failures continue to occur; however, more severe malfunctions such as the "runaway pump" phenomenon are rarely reported. This article describes two cases of pump malfunction in which pump users appear to have received an unsolicited bolus of insulin resulting in severe episodes of hypoglycemia during hospitalization. Both cases of insulin pump malfunction occurred in the inpatient setting at a large academic medical center in the United States. An analysis of the corresponding insulin pump downloads was performed. The Food and Drug Administration's (FDA's) Manufacturer and User Facility Device Experience (MAUDE) database was searched for similar cases involving Medtronic (Northridge, CA) insulin pumps using the terms "pump," "infusion," "insulin AND malfunction AND Medtronic." The two cases described show remarkable similarities, each demonstrating a severe hypoglycemic event preceded by an infusion site change followed by an alarm. In both cases a rapid spraying of insulin was reported. The insulin pump downloads validated much of the patients' and medical staff's descriptions of events. The FDA's MAUDE database search revealed 425 cases meeting our search term criteria. All cases were reviewed. Seven cases were identified involving independent movement of the reservoir piston. The cases detailed are the first to describe an insulin pump malfunction of this nature in the hospital setting involving unsolicited insulin boluses leading to severe hypoglycemia. The cases are particularly compelling in that they were witnessed by medical personnel. Providers and patients should receive instruction education on the recognition and management of insulin pump malfunction.

  17. Pulsatile versus steady infusions for hepatic artery chemotherapy

    International Nuclear Information System (INIS)

    Kim, E.E.; Haynie, T.P.; Wright, K.C.; Chaynsangavej, C.; Gianturco, C.; Lamki, L.; Wallace, S.

    1984-01-01

    Hepatic artery chemotherapy for unresectable liver tumors requires an even distribution of the drugs in the tumor or vascular bed. This cannot be determined angiographically because the drugs are infused at a much lower rate than the contrast media. It is easy, however, to determine the quality of the perfusion by injecting a small volume of Tc-99m MAA in one of the side ports while chemotherapeutic agent is being infused at the same rate. Usually this shows a uniform, satisfactory distribution of isotope. Occasionally, however, some areas fail to receive Tc-99m in spite of what appears to be a good position of the catheter tip. Since ''streaming'' of the infused drugs has been blamed for their uneven distribution, the authors decided to compare the usual steady flow infusions with infusions made pulsatile by the addition of a pulsing device (Gianturco Pump) attached to the infusion tubing. Eighty-three patients were studied with steady as well as pulsatile infusions. In 16 of these patients the perfusion pattern was definitely changed by the pulsatile infusion. In one patient the pulsatile mode resulted in an unwanted gastric perfusion. In 5 patients the distribution was improved in one hepatic lobe and in 10 patients it was improved in both lobes. These results show that hepatic artery perfusions can occasionally be improved by pulsing the infusate. However, pulsing can produce the unwanted perfusion of extra-hepatic areas

  18. [Research and application of microcontroller system for target controlled infusion].

    Science.gov (United States)

    Cheng, Yuke; Dou, Jianhong; Zhang, Xingan; Wang, Ruosong

    2005-08-01

    This paper presents a microcontroller system for target controlled infusion according to pharmacodynamic parameters of intravenous anesthetics. It can control the depth of anesthesia by adjusting the level of plasma concentrations. The system has the advantages of high precision, extending power and easy manipulation. It has been used in the clinical anesthesia.

  19. Treatment of advanced and recurrent squamous carcinoma of the uterine cervix with constant intraarterial infusion of cisplatin

    International Nuclear Information System (INIS)

    Rettenmaier, M.A.; Moran, M.F.; Ramsinghani, N.F.; Colman, M.; Syed, N.A.; Puthawala, A.; Jansen, F.W.; DiSaia, P.J.

    1988-01-01

    Twelve patients with primary or locally recurrent squamous carcinoma of the cervix were treated with constant internal iliac artery infusion of cisplatin (CDDP) via a totally implantable chemotherapy pump. Seven previously untreated patients received standard external and interstitial radiotherapy (RT) in conjunction with CDDP infusion. Five patients with isolated pelvic recurrences received CDDP therapy only. The chemotherapy pump was refilled weekly on an outpatient basis. All nine evaluable patients developed unilateral or bilateral lower extremity pain which responded to dosage reduction. No renal or marrow toxicity was seen. Both of the evaluable patients treated for recurrent tumor died 32 and 60 weeks after initiation of treatment. The seven patients treated primarily with RT + CDDP infusion include one who expired with persistent tumor and one with no evidence of disease (NED) after exenteration for a pelvic recurrence at 48 and 85 weeks respectively. The five remaining patients are NED at 12 to 60 weeks. Constant internal iliac artery infusion of CDDP via an implantable chemotherapy pump can be performed with acceptable toxicity. The preliminary results suggest that further study in previously untreated undergoing concurrent radiotherapy is warranted

  20. Chemical Stability of Telavancin in Elastomeric Pumps.

    Science.gov (United States)

    Sand, Patrick; Aladeen, Traci; Kirkegaard, Paul; LaChance, Dennis; Slover, Christine

    2015-12-01

    VIBATIV is a once-daily, injectable lipoglycopeptide antibiotic approved in the U.S. for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) caused by susceptible isolates of Staphylococcus aureus when alternative treatments are not suitable. In addition, VIBATIV is approved in the U.S. for the treatment of adult patients with complicated skin & skin structure infections (cSSSI) caused by susceptible isolates of Gram-positive bacteria, including Staphylococcus aureus, both methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) strains. To evaluate the chemical stability of telavancin (Vibativ; Theravance Biopharma US, Inc, Northbrook, Illinois), a lipoglycopeptide antibiotic with activity against methicillin-resistant Staphylococcus aureus, in 2 types of elastomeric pumps, the Intermate Infusion System (Baxter International Inc) and the Homepump Eclipse (I-Flow Corporation). Different sizes of the Baxter (Ontario, Canada) (105 mL and 275 mL) and I-Flow (Stoughton, Massachusetts) (100 mL and 250 mL) pumps were compared with glass controls. The telavancin drug product was reconstituted and diluted to concentrations of 0.6 mg/mL and 8.0 mg/mL using either 0.9% saline, 5% dextrose in water, or sterilized water for injection (0.6 mg/mL telavancin) or saline (8.0 mg/mL telavancin) followed by Ringer's Lactate solution. Pumps were filled and stored at 2°C to 8°C, protected from light. Aliquots from both pump types and for all telavancin reconstitution/dilution schemes and concentrations were taken over a period of 8 days and analyzed for appearance, pH, telavancin concentration and purity, and degradation products. The pH of all pump solutions remained consistent throughout the 8-day analysis period, within a range of 4.6 to 5.7 for the 0.6 mg/mL and 4.4 to 4.9 for the 8.0 mg/mL telavancin solutions. There was no significant change in the chromatographic purity for any of the pump solutions examined. All decreases in

  1. Acceptance for Beneficial Use Pumping Instrumentation and Control Skid N

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This is a final Acceptance for Beneficial Use (ABU) for Pumping and Instrumentation Control (PIC) skid ''N''. PIC skid ''N'' is ready for pumping tank U-109. All the testing and documentation has been completed as required on the AE3U checklist. This AE3U covers only the readiness of the PIC skid ''N''. Other U-farm preparations including dilution tank fabrication, portable exhauster readiness, leak detection, valve pit preparation, and the Operation Control Station readiness are not part of this ABU. PIC skid ''N'' is a new skid fabricated and tested at Site Fabrication Services. The skid controls the jet pump and monitors various instruments associated with the pumping operation. This monitoring includes leak detection along the waste transfer route and flammable gases in the pump pit. This Acceptance for Beneficial Use documents that Pumping Instrumentation and Control (PIC) skid ''N'' is ready for field use. This document does not cover the field installation or operational testing

  2. UK service level audit of insulin pump therapy in paediatrics.

    Science.gov (United States)

    Ghatak, A; Paul, P; Hawcutt, D B; White, H D; Furlong, N J; Saunders, S; Morrison, G; Langridge, P; Weston, P J

    2015-12-01

    To conduct an audit of insulin pump therapy in the UK after the issue of guidelines for the use of continuous subcutaneous insulin infusion by NICE in 2008 (Technology Appraisal 151). All centres in the UK, providing pump services to children and young people were invited to participate in an online audit. Audit metrics were aligned to NICE Technology Appraisal 151 and an electronic data collection tool was used. Of the 176 UK centres identified as providing pump services, 166 (94.3%) participated in the study. A total of 5094 children and young people were identified as using continuous subcutaneous insulin infusion (19% of all paediatric patients with Type 1 diabetes), with a median (range) of 16.9 (0.67-69.4)% per centre. Units had a median of 0.58 consultant sessions, 0.43 full-time equivalent diabetic specialist nurses, and 0.1 full-time equivalent dieticians delivering the pump service. The majority of this time was not formally funded. Families could access 24-h clinical and technical support (83% units), although the delivery varied between consultant, diabetic specialist nurse and company representatives. Only 53% of units ran, or accessed, structured education programmes for continuous subcutaneous insulin infusion use. Most units (86%) allowed continuous subcutaneous insulin infusion use for paediatric inpatients, but only 56% had written guidelines for this scenario. Nine percent of units had encountered funding refusal for a patient fulfilling NICE (Technology Appraisal 151) criteria. The number of children and young people on continuous subcutaneous insulin infusion therapy is consistent with numbers estimated by NICE. There is a worrying lack of funded healthcare professional time. The audit also identified gaps in the provision of structured education and absence of written inpatient guidelines. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.

  3. Baxter elastomeric pumps: Weighing as an alternative to visual inspection.

    Science.gov (United States)

    Cusano, Ellen L; Ali, Raafi; Sawyer, Michael B; Chambers, Carole R; Tang, Patricia A

    2018-04-01

    Purpose Elastomeric pumps are used to administer 46-hour infusions of 5-fluorouracil (5FU). Baxter suggests patients visually monitor their pumps to ensure that infusions are proceeding correctly. This can be confusing and lead to concerns about under- or over-dosing. Baxter has not considered weighing pumps as a validated method for monitoring. This study aims to validate weighing as a more accurate method for patients and healthcare professionals, and describe real life Baxter Infusor™ variability. Methods Patients who had been started on a 46-hour 5FU infusion returned to the clinic approximately 24 h after starting treatment. The pump was weighed on a StarFrit kitchen scale, and date, time, and weights recorded. Patients were asked if they had a preference for weighing or visually inspecting their pump. Results Pumps ( n = 103) were weighed between 17.25 and 27.5 h after connection. The average weight of a pump was 189 g. Of 103 pumps weighed, 99 weighed less than expected, corresponding to average flow rates of 5.69 mL/h over the elapsed time. The expected flow rate is 5 mL/h with 10% variability. Average flow rates within the 17.25- to 27.5-hour window were 4.561 mL/h, which is 8.78% slower than expected, but within the 10% known variability. Forty-seven percent of patients didn't have a preference for either method, but for those who did have a preference, more than twice as many preferred weighing. Conclusion With proper education, weighing Baxter Infusors at home with kitchen scales can be an accepted and objective alternative to the current recommendation of visual inspection.

  4. Does prolonged β-lactam infusions improve clinical outcomes compared to intermittent infusions? A meta-analysis and systematic review of randomized, controlled trials

    Directory of Open Access Journals (Sweden)

    Van Arendonk Kyle J

    2011-06-01

    Full Text Available Abstract Background The emergence of multi-drug resistant Gram-negatives (MDRGNs coupled with an alarming scarcity of new antibiotics has forced the optimization of the therapeutic potential of available antibiotics. To exploit the time above the minimum inhibitory concentration mechanism of β-lactams, prolonging their infusion may improve outcomes. The primary objective of this meta-analysis was to determine if prolonged β-lactam infusion resulted in decreased mortality and improved clinical cure compared to intermittent β-lactam infusion. Methods Relevant studies were identified from searches of MEDLINE, EMBASE, and CENTRAL. Heterogeneity was assessed qualitatively, in addition to I2 and Chi-square statistics. Pooled relative risks (RR and 95% confidence intervals (CI were calculated using Mantel-Haenszel random-effects models. Results Fourteen randomized controlled trials (RCTs were included. Prolonged infusion β-lactams were not associated with decreased mortality (n= 982; RR 0.92; 95% CI:0.61-1.37 or clinical cure (n = 1380; RR 1.00 95% CI:0.94-1.06 compared to intermittent infusions. Subgroup analysis for β-lactam subclasses and equivalent total daily β-lactam doses yielded similar results. Most studies had notable methodological flaws. Conclusions No clinical advantage was observed for prolonged infusion β-lactams. The limited number of studies with MDRGNs precluded evaluation of prolonged infusion of β-lactams for this subgroup. A large, multicenter RCT with critically ill patients infected with MDRGNs is needed.

  5. The role of elastomeric pumps in postoperative analgesia in orthopaedics and factors affecting their flow rate.

    Science.gov (United States)

    Theodorides, Anthony Andreas

    2017-12-01

    Elastomeric pumps are mechanical devices composed of an elastomeric balloon reservoir into which the drug to be infused is stored, a protective casing (used by some manufacturers), a flow controller and a wound catheter. In orthopaedics they are used to provide continuous local infiltration analgesia. In this way patients rely less on other routes of analgesia and thus avoid their systemic side effects. Studies have shown good response to analgesia with these pumps for the first 24 hours but their benefit is not as clear at 48 and 72 hours. There are numerous factors that affect the flow rate of elastomeric pumps. Some are inherent to all elastomeric pumps such as: the pressure exerted by the elastomeric balloon, catheter size, the vertical height of the pump in relation to the wound, viscosity and partial filling. There are also other factors which vary according to the manufacturer such as: the optimal temperature to obtain the desired flow rate as this directly affects viscosity, the dialysate that the analgesic drug is mixed with (ie normal saline or 5% dextrose), and the storage conditions of the fluid to be infused. It is thus essential to follow the clinical guidelines provided by the manufacturer in order to obtain the desired flow rate. Copyright the Association for Perioperative Practice.

  6. Sliding mode controller for a photovoltaic pumping system

    Science.gov (United States)

    ElOugli, A.; Miqoi, S.; Boutouba, M.; Tidhaf, B.

    2017-03-01

    In this paper, a sliding mode control scheme (SMC) for maximum power point tracking controller for a photovoltaic pumping system, is proposed. The main goal is to maximize the flow rate for a water pump, by forcing the photovoltaic system to operate in its MPP, to obtain the maximum power that a PV system can deliver.And this, through the intermediary of a sliding mode controller to track and control the MPP by overcoming the power oscillation around the operating point, which appears in most implemented MPPT techniques. The sliding mode control approach is recognized as one of the efficient and powerful tools for nonlinear systems under uncertainty conditions.The proposed controller with photovoltaic pumping system is designed and simulated using MATLAB/SIMULINK environment. In addition, to evaluate its performances, a classical MPPT algorithm using perturb and observe (P&O) has been used for the same system to compare to our controller. Simulation results are shown.

  7. A bispectral index guided comparison of target-controlled versus manually-controlled infusion of propofol and remifentanil for attenuation of pressor response to laryngoscopy and tracheal intubation in non cardiac surgery

    Directory of Open Access Journals (Sweden)

    Naser Yeganeh

    2006-12-01

    Full Text Available BACKGROUND: Target-controlled infusion is a new delivery system for intravenous anesthetic agents with which the anesthetist targets a plasma or effect-site drug concentration to achieve a predetermined effect. With this system, the tedious task of calculating the amount of administered drug required to achieve the target concentration is left in charge of a microprocessor which commands the infusion device. In this prospective study we compared alterations in blood pressure and heart rate from initiation of induction of anesthesia until 3 minutes after tracheal intubation in two methods of drug infusion, target-controlled infusion (TCI and manually controlled infusion (MCI. Total anesthetic drug used until 3 minutes after intubation and level of produced hypnosis also were compared between two methods. METHODS: 40 patients were enrolled in this clinical trial study and were allocated randomly in two groups, each group consisting of 20 patients. In TCI group, patients received propofol and remifentanil with TCI pump to achieve 7 µg/ml and 4 ng/ml as plasmatic target drug levels, respectively. In MCI group, patients received propofol 2 mg/kg and remifentanil 1 µg/kg of body weight with manually controlled infusion. Both groups received succinylcholine as muscle relaxant to facilitate laryngoscopy and tracheal intubation. Bispectral index (BIS was passively recorded in two groups to compare the level of hypnosis. Blood pressure (BP and heart rate (HR were recorded at 5 different times (T-1, T0, T1, T2 and T3. Independent t-test and paired t-test were used for data analysis. RESULTS: Systolic arterial pressure (SAP was not different at T-1 between two groups but systolic hypotension was seen in MCI group more than TCI group at T0 (P<0.05. Systolic hypertension was more common in MCI group after intubation; i.e. SAP showed significant differences in T1, T2 and T3 between two groups (P<0.05. Mean arterial pressure (MAP showed significant

  8. Precision flow-controlled Rb-82 generator for bolus or constant-infusion studies of the heart and brain

    International Nuclear Information System (INIS)

    Yano, Y.; Cahoon, J.L.; Budinger, T.F.

    1981-01-01

    A precision flow-controlled rubidium-82 generator has been constructed to deliver 76-sec Rb-82 at either fast or slow flow rates for bolus or constant-infusion studies. A stepping motor drive is interfaced to a microprocessor for pulsed control of flow rate to deliver the saline eluant solution from a large-volume (150 ml) machined pumping syringe through an alumina column that retains the 25-day Sr-82 parent. The generator system delivers 70-90% of the maximum Rb-82 activity in a 20-25 ml bolus elution of 2% NaCl. The Sr-82/Sr-85 breakthrough is 10 -7 - 10 -6 . Both yield and breakthrough are functions of column length and flow rate. Six separate Sr-82 loadings of the generator were evaluated over a period of nearly 2 yr in studies of myocardial blood perfusion and permeability changes in the blood-brain barrier. Sterility and apyrogenicity of the Rb-82 eluate were maintained during multiple elutions and long-term use of 3-4 mo for each generator loading

  9. Acceptance for Beneficial Use Pumping Instrumentation and Control Skid L

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This is a final Acceptance for Beneficial Use (ABU) for Pumping and Instrumentation Control (PIC) skid ''L''. PIC skid ''L'' is ready for pumping tank U-105. All the testing and documentation has been completed as required on the ABU checklist. This ABU covers only the readiness of the PIC skid ''L''. Other U-farm preparations including dilution tank fabrication, portable exhauster readiness, leak detection, valve pit preparation, and the Operation Control Station readiness are not part of this ABU. PIC skid ''L'' is a new skid fabricated and tested at Site Fabrication Services. The skid controls the jet pump and monitors various instruments associated with the pumping operation. This monitoring includes leak detection along the waste transfer route and flammable gases in the pump pit

  10. Verification of control system using inverter and canned motor pump

    International Nuclear Information System (INIS)

    Sawada, Yoshiaki; Misato, Hisashi

    2002-01-01

    Control on flow volume and so on of auxiliary systems at power stations is generally carried out by using control valves (CVs), of which numbers and kinds ranges to wide areas. CVs are required for periodical change of packing and so on, of which labor for maintenance is never few. Therefore, to reduce the maintenance of CVs, a system to operate pumps by using an inverter control was investigated. When carrying out flow control by an inverter, valves at output side of pumps was made perfectly open, but because of control on rotation numbers so as to keep required amount excess energy is never consumed. And, by reducing flow volume of a pump, consumed energy is reduced at a rate of its three powers as feature of pumps, so large energy saving effect can be established. Selected canned motor pumps have such characteristics as upgrading of reliability for leakage because of their seal-less ones and extension of periodical inspection period by setting a monitor for abrasion of bearings. As results of some investigations, it could be considered that a control system combining an inverter with a canned motor pump had equal feature as that of a control system using CVs. And, from a test result adding useless time and first order delay element to its control feature forecasting on its application to practical machine could be obtained. (G.K.)

  11. LOFT pump speed controller stability and accuracy analysis

    International Nuclear Information System (INIS)

    Good, R.R.

    1978-01-01

    Two system modifications to the primary coolant pumps motor generators control systems have recently been completed. The range of pump speed operation has been extended and the scoop tube positioner motor replaced. This has necessitated a re-analysis of PSMG stability throughout its range of operation. System accuracy requirements of less than 4 Hz differential pump speed when operating at less than 35 Hz and 8.5 Hz differential pump speed when operating at greater than 35 Hz can be guaranteed by specifying the gain of the system. The installation of the new scoop tube positioner motor will increase the PSMG system's bandwidth and stability. Low speed pump trips should be carefully evaluated if the pump's operational range is to extend to 10 Hz

  12. Medication and volume delivery by gravity-driven micro-drip intravenous infusion: potential variations during "wide-open" flow.

    Science.gov (United States)

    Pierce, Eric T; Kumar, Vikram; Zheng, Hui; Peterfreund, Robert A

    2013-03-01

    Gravity-driven micro-drip infusion sets allow control of medication dose delivery by adjusting drops per minute. When the roller clamp is fully open, flow in the drip chamber can be a continuous fluid column rather than discrete, countable, drops. We hypothesized that during this "wide-open" state, drug delivery becomes dependent on factors extrinsic to the micro-drip set and is therefore difficult to predict. We conducted laboratory experiments to characterize volume delivery under various clinically relevant conditions of wide-open flow in an in vitro laboratory model. A micro-drip infusion set, plugged into a bag of normal saline, was connected to a high-flow stopcock at the distal end. Vertically oriented IV catheters (gauges 14-22) were connected to the stopcock. The fluid meniscus height in the bag was fixed (60-120 cm) above the outflow point. The roller clamp on the infusion set was in fully open position for all experiments resulting in a continuous column of fluid in the drip chamber. Fluid volume delivered in 1 minute was measured 4 times with each condition. To model resistive effects of carrier flow, volumetric infusion pumps were used to deliver various flow rates of normal saline through a carrier IV set into which a micro-drip infusion was "piggybacked." We also compared delivery by micro-drip infusion sets from 3 manufacturers. The volume of fluid delivered by gravity-driven infusion under wide-open conditions (continuous fluid column in drip chamber) varied 2.9-fold (95% confidence interval, 2.84-2.96) depending on catheter size and fluid column height. Total model resistance of the micro-drip with stopcock and catheter varied with flow rate. Volume delivered by the piggybacked micro-drip decreased up to 29.7% ± 0.8% (mean ± SE) as the carrier flow increased from 0 to 1998 mL/min. Delivery characteristics of the micro-drip infusion sets from 3 different manufacturers were similar. Laboratory simulation of clinical situations with gravity

  13. Are late-night eating habits and sleep duration associated with glycemic control in adult type 1 diabetes patients treated with insulin pumps?

    Science.gov (United States)

    Matejko, Bartlomiej; Kiec-Wilk, Beata; Szopa, Magdalena; Trznadel Morawska, Iwona; Malecki, Maciej T; Klupa, Tomasz

    2015-07-01

    Little is known about the impact of sleep duration and late-night snacking on glycemic control in patients with type 1 diabetes using insulin pumps. The aim of the present study was to examine whether late-night eating habits and short sleep duration are associated with glycemic control in continuous subcutaneous insulin infusion-treated type 1 diabetic patients. We included 148 consecutive adult type 1 diabetic subjects using an insulin pump (100 women and 48 men). Participants completed a questionnaire regarding sleep duration (classified as short if ≤6 h) and late-night snacking. Other sources of information included medical records and data from blood glucose meters. Glycemic control was assessed by glycated hemoglobin (HbA1c) levels and mean self-monitoring of blood glucose (SMBG) readings. The mean age of patients was 26 years, mean type 1 diabetes duration was 13.4 years and mean HbA1c level was 7.2%. In a univariate regression analysis, sleep duration was a predictor of both HbA1c (β = 0.51, P = 0.01) and SMBG levels (β = 11.4, P = 0.02). Additionally, an association was found between frequent late-night snacking and higher SMBG readings (often snacking β = 18.1, P = 0.05), but not with increased HbA1c levels. In the multivariate linear regression, independent predictors for HbA1c and SMBG were sleep duration and patient age. In a univariate logistic regression, sleep duration and frequency of late-night snacking were not predictors of whether HbA1c target levels were achieved. Short sleep duration, but not late-night snacking, seems to be associated with poorer glycemic control in type 1 diabetic patients treated with continuous subcutaneous insulin infusion.

  14. Evaluation of the performance of elastomeric pumps in practice: are we under-delivering on chemotherapy treatments?

    Science.gov (United States)

    Salman, Dahlia; Biliune, Jurga; Kayyali, Reem; Ashton, Jane; Brown, Peter; McCarthy, Tim; Vikman, Elin; Barton, Stephen; Swinden, Julian; Nabhani-Gebara, Shereen

    2017-12-01

    Elastomeric pumps are widely used to facilitate ambulatory chemotherapy, and studies have shown that they are safe and well received by patients. Despite these advantages, their end of infusion time can fluctuate significantly. The aim of this research was to observe the performance of these pumps in real practice and to evaluate patients' satisfaction. This was a two-phase study conducted at three cancer units over 6 months. Phase-1 was an observational study recording the status of pumps at the scheduled disconnection time and noting remaining volume of infusion. Phase-2 was a survey of patients and their perception/satisfaction. Ethical approval was granted. A total of 92 cases were observed covering 50 cases disconnected at hospital and 42 disconnected at home. The infusion in 40% of hospital disconnection cases was slow, with patients arriving at hospital with unfinished pumps; 58% of these had an estimated remaining volume which exceeded 10 mL with 35% exceeded 20 mL. In 73% of these cases, and regardless of the remaining volume, the patient was disconnected and the pump was discarded. The performance of pumps varied, which affected nurse workload and patients' waiting-times. A smart system is an option to monitor the performance of pumps and to predict their accuracy.

  15. [The research on a pocket microcontroller system for target controlled infusion].

    Science.gov (United States)

    Cheng, Yu-Ke; Zhang, Xin-An; Zhang, Yan-Wu; Wu, Qun-Ling; Dou, Jian-Hong; Wang, Rou-Shong

    2005-05-01

    This paper present a microcontroller system for target controlled infusion according to pharmacodynamic parameters of intravenous anesthetics. It can control the depth of anesthesia by adjusting the level of plasma concentrations. The system has the advantages of high precision, extended function and easy operation. It has been now used in the clinical anesthesia.

  16. Identification of drug combinations administered by continuous subcutaneous infusion that require analysis for compatibility and stability

    OpenAIRE

    Dickman, Andrew; Bickerstaff, Matthew; Jackson, Richard; Schneider, Jennifer; Mason, Stephen; Ellershaw, John

    2017-01-01

    Background A continuous subcutaneous infusion (CSCI) delivered via syringe pump is a method of drug administration used to maintain symptom control when a patient is no longer able to tolerate oral medication. Several classes of drugs, such as opioids, antiemetics, anticholinergics, antipsychotics and benzodiazepines are routinely administered by CSCI alone or in combinations. Previous studies attempting to identify the most-common CSCI combinations are now several years old and no longer ref...

  17. Efficacy of an Intrathecal Multidrug Infusion for Pain Control in Older Adults and in End-Stage Malignancies: A Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Sadegh Abdolmohammadi

    2015-01-01

    Full Text Available The aim of the present study was to explore the effectiveness of an alternative method to manage pain based on a time-limited intrathecal (IT infusion of an analgesic medication mixture. Three patients (69, 64 and 94 years of age with intractable and poorly controlled pain due to bed sores, pelvic metastatic mass, and thoracic vertebra and rib fractures, respectively, were treated. Daily doses of opioids could not be increased due to side effects. An IT catheter (20 G was placed by percutaneous approach in the lumbar area while advancing toward the thoracic region, and was then tunnelled and fixed subcutaneously. It was connected to an external infusion pump with a mixture of bupivacaine 1 mg/mL, naloxone 0.02 ng/mL, ketamine 100 μg/mL, morphine 0.01 mg/mL and clonidine 0.75 μg/mL. The starting rate was 1 mL/h. The pain was mostly controlled at a rate of <1 mL/h. Opioid consumption was reduced dramatically. The catheter was kept in place for one month in the first and third patients, and for six months in the second patient, until his death. Major side effects, such as hypotension, constipation, muscle weakness, sphincter dysfunction, and cognitive or mood deterioration, were not observed with this approach. One patient experienced a urinary tract infection followed by sepsis and meningitis, which was cured by antibiotics. The catheter was removed in this patient. IT infusion with a low-concentration multidrug mixture could be considered as an alternative modality for intractable pain relief in older adults or in malignancies.

  18. Chronic suppression of testicular function by constant infusion of gonadotropin-releasing hormone agonist and testosterone supplementation in the bonnet monkey (Macaca radiata).

    Science.gov (United States)

    Ravindranath, N; Ramesh, V; Krishnamurthy, H N; Rao, A J; Moudgal, R N

    1992-03-01

    To study the efficacy of long-term buserelin acetate infusion to desensitize pituitary and block testicular function in adult male monkeys (Macaca radiata). Proven fertile male monkeys exhibiting normal testicular function. Each of the control (n = 5) and experimental monkeys (n = 10) received a fresh miniosmotic pump every 21 days, whereas pumps in controls delivered vehicle of experimentals released 50 micrograms buserelin acetate every 24 hours. On day 170 (renewed every 60 days) a silastic capsule containing crystalline testosterone (T) was implanted in the experimental monkeys. At the end of 3 years, treatment was stopped, and recovery of testicular function and fertility monitored. (1) Treatment resulted in marked reduction of nocturnal but not basal serum T; (2) the pituitary remained desensitized to buserelin acetate throughout the 3-year period; (3) animals were largely azoospermic with occasional oligospermia exhibited by two monkeys; and (4) withdrawal of treatment restored testicular function, with 70% of animals regaining fertility. Long-term infertility (but restorable) can be induced in male monkeys by constant infusion of buserelin acetate and T.

  19. Placebo versus low-dose ketamine infusion in addition to remifentanil target-controlled infusion for conscious sedation during oocyte retrieval: A prospective, double-blinded, randomised controlled trial.

    Science.gov (United States)

    Morue, Hélène I; Raj-Lawrence, Shalini; Saxena, Sarah; Delbaere, Anne; Engelman, Edgard; Barvais, Luc A

    2018-04-30

    Currently, there is no gold standard for monitored anaesthesia care during oocyte retrieval. In our institution, the standard is a conscious sedation technique using a target-controlled infusion (TCI) of remifentanil, titrated to maintain a visual analogue pain score less than 30 mm. This protocol is well accepted by patients but is associated with frequent episodes of respiratory depression. The main objective of this study was to evaluate whether the addition of a continuous intravenous infusion of ketamine could reduce these episodes. Controlled, randomised, prospective, double-blinded study. The current study was conducted in a tertiary-level hospital in Brussels (Belgium) from December 2013 to June 2014. Of the 132 women undergoing oocyte retrieval included, 121 completed the study. After randomisation, patients received either a ketamine infusion (40 μg kg min over 5 min followed by 2.5 μg kg min) or a 0.9% saline infusion in addition to the variable remifentanil TCI. The primary outcome was the number of respiratory depression episodes. Effect site target remifentanil concentrations, side effects, pain score, patient satisfaction and incidence of pregnancy were also recorded. No significant difference in the incidence of respiratory events was noted (pulse oximetry oxygen saturation the ketamine group and 63% in the control group; P = 0.121). No patient required ventilatory support. In the ketamine group, visual analogue pain score and remifentanil concentrations were significantly reduced, but the latter remained above 2 ng ml. Postoperative nausea was less frequent in the ketamine group, 4 versus 15% (P = 0.038). The addition of ketamine did not influence length of stay nor patient satisfaction. The addition of low plasma levels of ketamine to a TCI remifentanil conscious sedation technique did not decrease the incidence nor the severity of respiratory depression. Continuous monitoring of capnography and oxygen saturation is

  20. Continuous subcutaneous insulin infusion (CSII) therapy at Derby Teaching Hospitals: sustained benefits in glucose control.

    Science.gov (United States)

    Anyanwagu, U; Olaoye, H; Jennings, P; Ashton-Cleary, S; Sugunendran, S; Hughes, D; Idris, I; Wilmot, E G

    2017-08-01

    In the short term, continuous subcutaneous insulin infusion (CSII) has been associated with improved glycaemic control, reduced hypoglycaemia and improved quality of life (QOL). However, limited data are available on its long-term benefits, particularly in the UK. We aimed to assess the impact of CSII on longer term outcomes. Patient-level data were obtained for CSII users at Derby Teaching Hospitals, UK. Patient confidence and satisfaction questionnaires using the Likert scale were used to assess confidence in self-management. Comparative statistics were conducted using Pearson's chi-square and Student's t-tests. Some 258 CSII users were identified (60.1% female, mean age 43.9 ± 13.4 years). Overall, there was significant decrease in HbA 1c from 78 mmol/mol (9.3 ± 2.0%) at baseline, to 69 mmol/mol (8.5 ± 1.3%) at 6 months [mean difference (md): -0.64; 95% confidence interval (95% CI): -0.91 to -0.37; P quality of care received in the insulin pump service. CSII therapy led to a sustained long-term improvement in glycaemic control in addition to a reduction in self-reported hypoglycaemia. © 2017 Diabetes UK.

  1. D0 HVAC System Heat Pump Controller Programming, Networking, and Operating Information

    International Nuclear Information System (INIS)

    Anderson, B.

    1999-01-01

    The purpose of this engineering note is to provide the necessary information to setup, program, and network the Electronic Systems USA Heat Pump Controller with the LON network card and Intellution Fix32 to operate properly within the HVAC system at D-Zero. The heat pump controllers are used for local temperature control of the office environments on the fifth and six floors of D-Zero. Heat pump units 1-6 are located in the ceiling of the sixth floor. Heat pump units 7-12 are found in the fifth floor ceiling. Heat pump unit 13 is in the Southeast corner of the fifth floor. Prior to installation the heat pump controller must be properly prepared to operate correctly in the HVAC system. Each heat pump unit must contain firmware (software) version 1.31 to operate properly on the network. Controllers with version 1.30 will not be able to communicate over the LON network. The manufacturer can only update the firmware version. Before installation a series of heat pump setpoints must be manually set using the Intelligent Stat. Connect the Intelligent Stat via the serial cable or wired connection.

  2. Self-pumping inpurity control systems for INTOR

    International Nuclear Information System (INIS)

    Brooks, J.N.; Mattas, R.F.; Smith, D.L.; Hassanein, A.M.

    1987-01-01

    Two self-pumping systems have been examined for use as the INTOR impurity control system. The systems work by trapping helium in freshly deposited metal surface layers on or near the divertor plate. A slot divertor concept using vanadium or other trapping material appears to be both feasible and mechanically simple, and offers significant advantages in cost, reduced complexity, and helium pumping efficiency for the INTOR design

  3. Gated-controlled electron pumping in connected quantum rings

    International Nuclear Information System (INIS)

    Lima, R.P.A.; Domínguez-Adame, F.

    2014-01-01

    We study the electronic transport across connected quantum rings attached to leads and subjected to time-harmonic side-gate voltages. Using the Floquet formalism, we calculate the net pumped current generated and controlled by the side-gate voltage. The control of the current is achieved by varying the phase shift between the two side-gate voltages as well as the Fermi energy. In particular, the maximum current is reached when the side-gate voltages are in quadrature. This new design based on connected quantum rings controlled without magnetic fields can be easily integrated in standard electronic devices. - Highlights: • We introduce and study a minimal setup to pump electrons through connected quantum rings. • Quantum pumping is achieved by time-harmonic side-gate voltages instead of the more conventional time-dependent magnetic fluxes. • Our new design could be easily integrated in standard electronic devices

  4. Design and performance evaluation of the "iTIVA" algorithm for manual infusion of intravenous anesthetics based on effect-site target

    NARCIS (Netherlands)

    D.E. Ramírez (David Eduardo); J.A. Calvache (Jose Andrés)

    2016-01-01

    textabstractIntroduction: Remifentanil and propofol infusion using TCI pumps has proven to be beneficial for the practice of anesthesia but the availability of these systems is limited. Objective: Designing a pharmacokinetic model-based algorithm for calculating manual infusion regimens to achieve

  5. Feedback control of primary circulation pump of PIUS-Type reactor

    International Nuclear Information System (INIS)

    Fujii, Mikiya; Anoda, Yoshinari; Murata, Hideo; Yonomoto, Taisuke; Kukita, Yutaka; Tasaka, Kanji.

    1991-05-01

    In operating the PIUS-Type reactor, it is required to keep stationary density interfaces between the primary loop hot water and the poison tank cold, borated water by maintaining pressure balance between the primary-loop and the poison-tank. The authors have developed a primary circulation pump speed control system and tested it in small-scale experiments. This control system regulates the pump speed based on measurements of the density lock differential pressure which is proportional to the elevation of the interface in the density lock. This pump speed control facilitated the normal plant operation which included core power changes. However, the elevation of the density interface indicated oscillatory behavior when the pump speed was regulated as a linear function of the density lock differential pressure. The mechanism responsible for such oscillatory behavior was found to be manometric oscillations that could be eliminated by adding a damping term to compensate for the mechanical delay of the primary pump speed. The passive shutdown function of the reactor was retained by setting an upper limit to the pump speed. This was confirmed in a loss-of-feedwater abnormal transient test. (author)

  6. Continuous intraperitoneal insulin infusion in the treatment of type 1 diabetes mellitus: Glycaemia and beyond

    OpenAIRE

    van Dijk, Peter R.

    2015-01-01

    Continuous intraperitoneal insulin infusion (CIPII) with an implantable pump is a last-resort treatment option for selected patients with type 1 diabetes mellitus (T1DM). As compared to the most commonly used forms of insulin administration -injections and an externally placed pump- which deliver insulin in the subcutaneous (SC) tissue, CIPII delivers the insulin in the intraperitoneal space. CIPII using an implantable pump is an unique treatment which has been available for more than 30 year...

  7. Current status of patient-controlled analgesia in cancer patients.

    Science.gov (United States)

    Ripamonti, C; Bruera, E

    1997-03-01

    Patient-controlled analgesia (PCA) is a relatively new technique in which patients are able to self-administer small doses of opioid analgesics when needed. Many different devices are available for opioid infusion, including a syringe pump, disposable plastic cylinder, and battery-operated computer-driven pump. These devices allow patients to choose an intermittent (demand) bolus, continuous infusion, or both modes of administration. Parameters, such as route, drug concentration dose, frequency, and maximum daily or hourly dose, are programmed by the physician. The patient decides whether or not to take a dose. Devices can be used to deliver the drug into a running intravenous infusion, the epidural space, or subcutaneously. Controlled trials indicate that PCA is probably superior to regular opioid administration in postoperative pain. Reported advantages include greater patient satisfaction, decreased sedation and anxiety, and reduced nursing time and hospitalization. Preliminary experience suggests that PCA is also useful and safe for cancer pain, but further research is greatly needed.

  8. Elimination of Oscillations in a Central Heating System using Pump Control

    DEFF Research Database (Denmark)

    Andersen, Palle; Pedersen, Tom Søndergaard; Stoustrup, Jakob

    2000-01-01

    In central heating systems with thermostatic valve temperature control it is a well known fact that room temperature oscillations may occur when the heat demand becomes low due to the non-linear behavior of the control loop. This is not only discomforting but it also increases the energy cost...... of heating the room. Using the pump speed as an active part in control is it shown that the room temperature may be stabilized in a wider interval of heat demand. The idea is to control the pump speed in a way that keeps the thermostatic valve within a suitable operating area using an estimate of the valve...... position. The position is estimated from the pump terminals, using the pump flow and the pump differential pressure. The concept is tested on a small central heating test bench. The results show that it is possible to stabilize the room temperature even at part load conditions...

  9. Test report - 241-AN-274 Caustic Pump Control Building

    International Nuclear Information System (INIS)

    Paintner, G.P.

    1995-05-01

    This Acceptance Test Report documents the test results of test procedure WHC-SD-WM-ATP-135 'Acceptance Test Procedure for the 241-AN- 274 Caustic Pump Control Building.' The objective of the test was to verify that the 241-AN-274 Caustic Pump Control Building functions properly based on design specifications per applicable H-2-85573 drawings and associated ECN's. The objective of the test was met

  10. Advanced Control of Wind Electric Pumping System for Isolated Areas Application

    OpenAIRE

    Mohamed Barara; Abderrahim Bennassar; Ahmed Abbou; Mohammed Akherraz; Badre Bossoufi

    2014-01-01

    The supply water in remote areas of windy region is one of most attractive application of wind energy conversion .This paper proposes an advanced controller suitable for wind-electric pump in isolated applications in order to have a desired debit from variation of reference speed of the pump also the control scheme of DC voltage of SIEG for feed the pump are presented under step change in wind speed. The simulation results showed a good performance of the global proposed control system.

  11. Mold Heating and Cooling Pump Package Operator Interface Controls Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Josh A. Salmond

    2009-08-07

    The modernization of the Mold Heating and Cooling Pump Package Operator Interface (MHC PP OI) consisted of upgrading the antiquated single board computer with a proprietary operating system to off-the-shelf hardware and off-the-shelf software with customizable software options. The pump package is the machine interface between a central heating and cooling system that pumps heat transfer fluid through an injection or compression mold base on a local plastic molding machine. The operator interface provides the intelligent means of controlling this pumping process. Strict temperature control of a mold allows the production of high quality parts with tight tolerances and low residual stresses. The products fabricated are used on multiple programs.

  12. Analysis of Decentralized Control for Absorption Cycle Heat Pumps

    DEFF Research Database (Denmark)

    Vinther, Kasper; Just Nielsen, Rene; Nielsen, Kirsten Mølgaard

    2015-01-01

    Email Print Request Permissions This paper investigates decentralized control structures for absorption cycle heat pumps and a dynamic nonlinear model of a single-effect LiBr-water absorption system is used as case study. The model has four controllable inputs, which can be used to stabilize...... the operation of the heat pump under different load conditions. Different feasible input-output pairings are analyzed by computation of relative gain array matrices and scaled condition numbers, which indicate the best pairing choice and the potential of each input-output set. Further, it is possible...... to minimize the effect of cross couplings and improve stability with the right pairing of input and output. Simulation of selected candidate input-output pairings demonstrate that decentralized control can provide stable operation of the heat pump....

  13. Intrathecal catheter-syringe adaptor for short-term intrathecal analgesia with an externalized pump: a case report.

    Science.gov (United States)

    Wilkes, Denise; Cook, Michael; Solanki, Daneshvari

    2010-01-01

    attached to an external drug infusion pump. We report the successful use of the Medtronic Indura 1P, one piece intrathecal catheter, connected to the external drug pump for a 3 week period in a patient with metastatic cervical cancer for palliative pain control. Case report only. This technique is simple to perform by pain specialists. The catheter modification allows the use of the Medtronic intrathecal catheter with standard external drug infusion pumps. This facilitates the patient's care in the hospice setting.

  14. Designing an Electro-Hydraulic Control Module for an Open-Circuit Variable Displacement Pump

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen; Andersen, Torben Ole; Hansen, Michael Rygaard

    2005-01-01

    , in the form of an electric control signal, under varying working conditions, when having access to engine speed and actual pump pressure. The paper presents a model of both the pump and the control module, along with design considerations on which linear controllers are developed for a worst point......This paper deals with the problem of designing an electric control module for a Sauer-Danfoss Series 45 H-frame open circuit axial piston pump. The purpose of the electric control module is to replace the existing hydro-mechanical (LS) regulator, and enable the pump to follow a reference pressure...

  15. Effect of different infusion regimens on colonic motility and efficacy of colostomy irrigation.

    Science.gov (United States)

    Gattuso, J M; Kamm, M A; Myers, C; Saunders, B; Roy, A

    1996-10-01

    The colonic motility response and short-term clinical effectiveness of colonic irrigation was studied in five patients with an end-colostomy, each of whom was studied on up to six occasions, using volumes of 500 and 1500 ml water infused under gravity and over a period of 2.5 and 5 min with a pump. The median baseline colonic luminal pressure was 14 cmH2O and rose to 42 cmH2O with a 500-ml infusion, and to 74 cmH2O with a 1500-ml infusion. Irrigation induced high-pressure (over 200 cmH2O) propagated waves which caused the efflux of colonic contents. These were more numerous after a 1500- than a 500-ml infusion (median 4.5 versus 2.0 respectively). There was no difference between the two volumes infused in the incidence of colostomy break-through before subsequent irrigation. Colostomy irrigation with 500-1500 ml water appears to produce intracolonic pressure rises that are safe. These volumes can be infused rapidly under gravity alone.

  16. Safe intravenous administration in pediatrics: A 5-year Pediatric Intensive Care Unit experience with smart pumps.

    Science.gov (United States)

    Manrique-Rodríguez, S; Sánchez-Galindo, A C; Fernández-Llamazares, C M; Calvo-Calvo, M M; Carrillo-Álvarez, Á; Sanjurjo-Sáez, M

    2016-10-01

    To estimate the impact of smart pump implementation in a pediatric intensive care unit in terms of number and type of administration errors intercepted. Observational, prospective study carried out from January 2010 to March 2015 with syringe and great volumen infusion pumps available in the hospital. A tertiary level hospital pediatric intensive care unit. Infusions delivered with infusion pumps in all pediatric intensive care unit patients. Design of a drug library with safety limits for all intravenous drugs prescribed. Users' compliance with drug library as well as number and type of errors prevented were analyzed. Two hundred and eighty-three errors were intercepted during 62 months of study. A high risk drug was involved in 58% of prevented errors, such as adrenergic agonists and antagonists, sedatives, analgesics, neuromuscular blockers, opioids, potassium and insulin. Users' average compliance with the safety software was 84%. Smart pumps implementation has proven effective in intercepting high risk drugs programming errors. These results might be exportable to other critical care units, involving pediatric or adult patients. Interdisciplinary colaboration is key to succeed in this process. Copyright © 2016 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  17. Feasibility of saline infusion on the liver surface during radiofrequency ablation of subcapsuIar hepatic tumor: an experimentaI study

    International Nuclear Information System (INIS)

    Lee, Young Rang; Kim, Young Sun; Rhim, Hyun Chul; Seo, Heung Suk; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Kim, Sung Kyu; Paik, Seung Sam

    2004-01-01

    The purpose of the study was to evaluate the feasibility of infusion of normal saline onto the surface of the liver capsule for minimizing thermal injury of the adjacent organs during radiofrequency ablation of subcapsular hepatic tumor in an ex-vivo porcine model. We used porcine small bowel with it's serosal surface spread onto the porcine liver as an experiment model. The puncturing electrode was inserted into a 6 Fr introducer sheath, and the introducer sheath was connected to the infusion pump for creating a saline flow over the liver surface. A total of 15 ablations were divided into the control group (n=5), intermittent saline infusion group (n=5) and continuous saline infusion (n=5) group. The ablations were done during 3 minutes, and the infusion was set at 2 ml/min and stopped every 30 seconds in the intermittent saline infusion group. After the ablation, we measured the size of the ablated lesion on the surface of bowel and liver, and we also measured the depth of hepatic lesion. Ablated areas of bowel and liver surface in the control group, intermittent saline infusion group and continuous infusion group were 210.7±89.1 mm 2 , 74.6±27.2 mm 2 and 35.8±43.4 mm 2 , respectively, and 312.6±73.6 mm 2 , 228.4±110.5 mm 2 , and 80.9±55.1 mm 2 , respectively. In contrast to the broad base of the ablated area on the surface of the liver in the control group, the shapes of the lesions became narrower approaching to the liver surface in all cases of the continuous saline infusion group, and the shapes of the lesions were broad based in 3 cases and narrow based in 2 cases of the intermittent saline infusion group. Continuous infusion of normaI saline onto the surface of the liver during radiofrequency ablation of subcapsular hepatic tumor is a feasible method for minimizing thermal injury of the adjacent organs. Further exploration of the optimal parameters or techniques to maximize the hepatic ablation and simultaneously to minimize the thermal injury of

  18. Delivery interaction between co-infused medications: an in vitro modeling study of microinfusion.

    Science.gov (United States)

    Tsao, Amy C; Lovich, Mark A; Parker, Michael J; Zheng, Hui; Peterfreund, Robert A

    2013-01-01

    To test the hypothesis that steady-state drug delivery by continuous infusion is predictably affected by a second drug infusion in the same lumen. Clinicians commonly administer two drugs by continuous infusion through one central venous catheter lumen (co-infusion). To limit fluid delivery, low flow rate carriers transport concentrated drug solutions; a method called microinfusion. How microinfusion delivery of one drug is affected by a second drug infusion has not been explored. Two water-soluble dyes, tartrazine and erioglaucine, infused at 3 ml · h(-1), modeled drug delivery through a four stopcock linear manifold and catheter lumen. A pump drove a carrier fluid (10 ml · h(-1)). After tartrazine reached steady-state delivery, erioglaucine entered downstream or upstream of the tartrazine infusion. Quantitative spectrophotometry measured dye delivery. Starting erioglaucine's infusion upstream of tartrazine's entry caused a transient tartrazine bolus (duration 10 min, peak drug delivery 20% higher than target levels). Starting erioglaucine's infusion downstream produced a similar amplitude, briefer, bolus. Stopping the erioglaucine infusion caused a transient reduction in tartrazine delivery. Measured delivery profiles were comparable to prediction models. We confirmed the hypothesis that delivery of one infused drug is transiently affected by starting or stopping a second drug infusion in the same line. The magnitude of the changes can be estimated quantitatively. The clinical impact depends on the drugs being co-infused and patient sensitivity, but could be clinically important; the findings have safety implications for infused medication delivery to critically ill or anesthetized children. We recommend minimizing infusion system dead volumes, connecting the most essential infusion(s) to the main fluid pathway as close as possible to the patient, and recognizing the potential for unintended alterations in delivery when multiple drugs co-infuse. © 2012

  19. An automatic control of the pumping system for the vacuum chamber of the cyclotron

    International Nuclear Information System (INIS)

    Ikegami, Kumio; Kageyama, Tadashi; Kohno, Isao

    1979-01-01

    The main pumping system of the 160 cm cyclotron is composed of 32'', 14'', and 6'' oil difusion pumps connected in series and rough pumping system which consists of 1500 l/min rotary pump and 300 m 3 /h roots pump with 650 l/min rotary backing pump. Instead of manual operation an automatic control devise of the pumping system was developed and many valves were replaced with pneumatic ones. In the new control system, pumps and valves are operated automatically, according to the indication of pirani detectors, to evacuate the chamber of the cyclotron up to the pressure of 0.7 - 1.0 x 10 -6 Torr, and also to protect the pumping system against vacuum failure by accidental leakage in the chamber. The graphic handling board of the pumping system is installed on the control panel and each switch is provided with a name card showing its function briefly. (author)

  20. Comparison of rechargeable versus battery-operated insulin pumps: temperature fluctuations.

    Science.gov (United States)

    Vereshchetin, Paul; McCann, Thomas W; Ojha, Navdeep; Venugopalan, Ramakrishna; Levy, Brian L

    2016-01-01

    The role of continuous subcutaneous insulin infusion (insulin pumps) has become increasingly important in diabetes management, and many different types of these systems are currently available. This exploratory study focused on the reported heating issues that lithium-ion battery-powered pumps may have during charging compared with battery-operated pumps. It was found that pump temperature increased by 6.4°C during a long charging cycle of a lithiumion battery-operated pump under ambient temperatures. In an environmental-chamber kept at 35°C, the pump temperature increased by 4.4°C, which indicates that the pump temperature was above that of the recommended safety limit for insulin storage of 37°C. When designing new pumps, and when using currently available rechargeable pumps in warmer climates, the implications of these temperature increases should be taken into consideration. Future studies should also further examine insulin quality after charging.

  1. Vacuum pumping for controlled thermonuclear reactors

    International Nuclear Information System (INIS)

    Watson, J.S.; Fisher, P.W.

    1976-01-01

    Thermonuclear reactors impose unique vacuum pumping problems involving very high pumping speeds, handling of hazardous materials (tritium), extreme cleanliness requirements, and quantitative recovery of pumped materials. Two principal pumping systems are required for a fusion reactor, a main vacuum system for evacuating the torus and a vacuum system for removing unaccelerated deuterium from neutral beam injectors. The first system must pump hydrogen isotopes and helium while the neutral beam system can operate by pumping only hydrogen isotopes (perhaps only deuterium). The most promising pumping techniques for both systems appear to be cryopumps, but different cryopumping techniques can be considered for each system. The main vacuum system will have to include cryosorption pumps cooled to 4.2 0 K to pump helium, but the unburned deuterium-tritium and other impurities could be pumped with cryocondensation panels (4.2 0 K) or cryosorption panels at higher temperatures. Since pumping speeds will be limited by conductance through the ducts and thermal shields, the pumping performance for both systems will be similar, and other factors such as refrigeration costs are likely to determine the choice. The vacuum pumping system for neutral beam injectors probably will not need to pump helium, and either condensation or higher temperature sorption pumps can be used

  2. Economic COP Optimization of a Heat Pump with Hierarchical Model Predictive Control

    DEFF Research Database (Denmark)

    Tahersima, Fatemeh; Stoustrup, Jakob; Rasmussen, Henrik

    2012-01-01

    A low-temperature heating system is studied in this paper. It consists of hydronic under-floor heating pipes and an air/ground source heat pump. The heat pump in such a setup is conventionally controlled only by feed-forwarding the ambient temperature. Having shown >10% cut-down on electricity bi....... The proposed control strategy is a leap forward towards balanced load control in Smart Grids where individual heat pumps in detached houses contribute to preserve load balance through intelligent electricity pricing policies....

  3. Chemical Stability of Telavancin in Elastomeric Pumps

    Directory of Open Access Journals (Sweden)

    Patrick Sand, MSc

    2015-12-01

    Conclusions: The results of this study indicate that telavancin remains chemically stable when diluted in the Intermate Infusion System and the Homepump Eclipse elastomeric pumps and stored at 2°C to 8°C for up to 8 days protected from light at the concentration range and dilution schemes evaluated.

  4. Sensorless Sinusoidal Drives for Fan and Pump Motors by V/f Control

    Science.gov (United States)

    Kiuchi, Mitsuyuki; Ohnishi, Tokuo

    This paper proposes sensorless sinusoidal driving methods of permanent magnet synchronous motors for fans and pumps by V/f control. The proposed methods are simple methods that control the motor peak current constant by voltage or frequency control, and are characterized by DC link current detection using a single shunt resistor at carrier wave signal bottom timing. As a result of the dumping factor from square torque load characteristics of fan and pump motors, it is possible to control stable starting and stable steady state by V/f control. In general, pressure losses as a result of the fluid pass of fan and pump systems are nearly constant; therefore, the flow rate and motor torque are determined by revolutions. Accordingly, high efficiency driving is possible by setting corresponding currents to q-axis currents (torque currents) at target revolutions. Because of the simple current detection and motor control methods, the proposed methods are optimum for fan and pump motor driving systems of home appliances.

  5. Earliest Deadline Control of a Group of Heat Pumps with a Single Energy Source

    Directory of Open Access Journals (Sweden)

    Jiří Fink

    2016-07-01

    Full Text Available In this paper, we develop and investigate the optimal control of a group of 104 heat pumps and a central Combined Heat and Power unit (CHP. The heat pumps supply space heating and domestic hot water to households. Each house has a buffer for domestic hot water and a floor heating system for space heating. Electricity for the heat pumps is generated by a central CHP unit, which also provides thermal energy to a district heating system. The paper reviews recent smart grid control approaches for central and distributed levels. An online algorithm is described based on the earliest deadline first theory that can be used on the aggregator level to control the CHP and to give signals to the heat pump controllers if they should start or should wait. The central controller requires only a limited amount of privacy-insensitive information from the heat pump controllers about their deadlines, which the heat pump controllers calculate for themselves by model predictions. In this way, a robust heat pump and CHP control is obtained, which is able to minimize energy demand and results in the desired thermal comfort for the households. The simulations demonstrate fast computation times due to minor computational and communication overheads.

  6. Continuous infusion versus daily injections of growth hormone (GH) for 4 weeks in GH-deficient patients

    DEFF Research Database (Denmark)

    Laursen, Torben; Jørgensen, Jens Otto Lunde; Jakobsen, Grethe

    1995-01-01

    effects with constant and pulsatile GH delivery. This study was carried out to compare the metabolic effects of longer term continuous infusion vs. daily injections of GH. Thirteen GH-deficient patients were studied in a cross-over design. The patients were randomized to receive GH as a continuous sc...... infusion by means of a portable pump for 1 month and as daily sc injections (at 1900 h) for another month. An average daily GH dosage (+/- SEM) of 3.15 +/- 0.27 IU was administered during both periods. Steady state 24-h profiles of GH, IGF-I, IGF-binding proteins (IGFBPs), insulin, glucose, lipid.......35 (infusion); P infusion induced higher nighttime than daytime GH levels (P = 0.01), indicating a diurnal variation in the absorption or clearance of GH. Serum IGF-I levels (micrograms per L) were slightly higher (P infusion [312...

  7. Remifentanil for labour analgesia: a double-blinded, randomised controlled trial of maternal and neonatal effects of patient-controlled analgesia versus continuous infusion.

    Science.gov (United States)

    Shen, M K; Wu, Z F; Zhu, A B; He, L L; Shen, X F; Yang, J J; Feng, S W

    2013-03-01

    This trial aimed to compare the maternal and neonatal effects of remifentanil given by patient-controlled analgesia (PCA) or continuous infusion for labour analgesia. Patient controlled analgesia was administered using increasing stepwise boluses from 0.1 to 0.4 μg.kg(-1) (0.1 μg.kg(-1) increment, 2 min lockout, n = 30). Continuous infusion used rates from 0.05 to 0.2 μg.kg(-1) .min(-1) (0.05 μg.kg(-1) .min(-1) increment, n = 30). Dose increments were given on request. Women reported lowest pain scores (median (IQR [range]) of 3 (2-4 [2-5]) for PCA and 4 (3-5.25 [3-7]) for continuous infusion (p = 0.004) at 60 min after the beginning of analgesia. The mean (SD) remifentanil umbilical vein/maternal artery ratio in the PCA and infusion groups were 0.74 (0.45) vs 0.70 (0.52), respectively (p = 0.776). The mean (SD) umbilical artery/umbilical vein ratios were 0.31 (0.12) vs 0.26 (0.07), respectively (p = 0.088). Maternal and neonatal adverse reactions of remifentanil were similar between the two groups. The total remifentanil consumption (median (IQR [range]) during PCA administration was lower than continuous infusion, 1.34 (1.22-1.48 [0.89-1.69]) mg vs 1.49 (1.35-1.61 [1.12-1.70] mg; p = 0.011). The results suggest that remifentanil PCA provides better pain relief and similar placental transfer compared with continuous infusion. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  8. Computer-Based Monitoring and Remote Controlling for Oil Well Pumps Using Scada

    Directory of Open Access Journals (Sweden)

    Rudi Tjiptadi

    2011-12-01

    Full Text Available The research aims to change manually the monitoring and controlling of oil well pumps into a computer-based system using SCADA (Supervisory and Data Acquisition system. To design the protection system which consists of controller unit and display system, RTU (Remote Terminal Unit and MTU (Master Terminal Unit are used. The research results in a controller unit which is able to communicate to personal computer using RS-232 C and an alarm system to protect oil pump motors by detecting sensors installed at the pumps

  9. High aspect ratio, remote controlled pumping assembly

    Science.gov (United States)

    Brown, Steve B.; Milanovich, Fred P.

    1995-01-01

    A miniature dual syringe-type pump assembly which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor.

  10. A computer-controlled syringe driver for use during anaesthesia. A modification of the Graseby MS16A.

    Science.gov (United States)

    Cohen, A T

    1986-06-01

    The requirements of a drug infusion device for use in theatre are discussed. A modification of the Graseby MS16A syringe pump and an interface circuit permitting its remote control by microcomputer are described. The pump is controlled via a standard computer interface (RS232) which makes it a unique and powerful research tool. Aspects of safety are considered.

  11. Study of high-pressure cryogenic pumps with different methods of delivery control

    International Nuclear Information System (INIS)

    Braun, V.M.; Brailovskii, Y.L.; Pavlenko, Y.A.; Tsokalo, I.V.

    1986-01-01

    This paper describes new reciprocating pumps with smooth control of delivery in a running pump. Control is effected either by changing the length of the piston stroke or by changing the speed of the driving motor. The individual features of the two methods are described. In the first method (mechanical), delivery is controlled in the range 50 to 100%. A separate actuating mechanism is needed to connect the pump to an automatic control system. This method complicates the driving mechanism and increases the bulk and cost of production. In the second method of controlling the speed of the electric motor, an electric drive fitted with a frequency thyristor is used. AC induction motors series 4A working at current frequencies of 60 HZ are used. By this method, delivery control could be enhanced by 1.3 times. Comparative tests were made on pumps using the above methods of control. The tests demonstrated the possibilities of using the frequency thyristor converters. The complexity and high cost of EKT type drives is largely compensated by the convenience and simplicity of control in a wide range. The mechanical control is advantageous only in low-output units

  12. In silico evaluation of a control system and algorithm for automated insulin infusion in the ICU setting

    Directory of Open Access Journals (Sweden)

    Olmos Pablo R

    2010-07-01

    Full Text Available Abstract Background It is known that tight control of glucose in the Intensive Care Unit reduces morbidity and mortality not only in diabetic patients but also in those non-diabetics who become transiently hyperglycemic. Taking advantage of a recently marketed subcutaneous glucose sensor we designed an Automatic Insulin Infusion System (AIIS for inpatient treatment, and tested its stability under simulated clinical conditions. Methods The system included: reference glucose, glucose sensor, insulin and glucose infusion controllers and emergency infusion logic. We carried out computer simulations using Matlab/Simulink®, in both common and worst-case conditions. Results The system was capable of controlling glucose levels without entering in a phase of catastrophic instability, even under severe simulated challenges. Care was taken to include in all simulations the 5-10 minute delay of the subcutaneous glucose signal when compared to the real-time serum glucose signal, a well-known characteristic of all subcutaneous glucose sensors. Conclusions When tested in-Silico, a commercially available subcutaneous glucose sensor allowed the stable functioning of a proportional-derivative Automatic Insulin Infusion System, which was able to maintain glucose within acceptable limits when using a well-established glucose response model simulating a patient. Testing of the system in vivo using animal models is now warranted.

  13. Comparison of peristaltic and Venturi pumps in bimanual microincisional cataract surgery.

    Science.gov (United States)

    Karaguzel, Hande; Karalezli, Aylin; Aslan, Bekir Sitki

    2009-12-01

    Comparison of peristaltic and Venturi pumps in bimanual microincision phacoemulsification on the success of the cataract surgery by using sleeveless phaco tip. Bimanual microincision phacoemulsification was done in 49 eyes using a 1.4-mm temporal clear corneal incision. A peristaltic pump was used in 23 eyes, and a Venturi pump was used in 26 eyes for phacoemulsification. Intraoperative complications, anterior chamber stability, and mean duration of surgery were recorded. Duration of surgery was shorter in the Venturi pump group. Anterior chamber stability could not be established in 17 eyes in the peristaltic pump group; it was established in all eyes in the Venturi pump group. Corneal burns were observed in two eyes in the peristaltic pump group and no eyes in the Venturi pump group. Use of a Venturi pump system and a vented gas-forced infusion system can significantly shorten surgery time and reduce risk of thermal burns.

  14. Low-dose copper infusion into the coronary circulation induces acute heart failure in diabetic rats: New mechanism of heart disease.

    Science.gov (United States)

    Cheung, Carlos Chun Ho; Soon, Choong Yee; Chuang, Chia-Lin; Phillips, Anthony R J; Zhang, Shaoping; Cooper, Garth J S

    2015-09-01

    Diabetes impairs copper (Cu) regulation, causing elevated serum Cu and urinary Cu excretion in patients with established cardiovascular disease; it also causes cardiomyopathy and chronic cardiac impairment linked to defective Cu homeostasis in rats. However, the mechanisms that link impaired Cu regulation to cardiac dysfunction in diabetes are incompletely understood. Chronic treatment with triethylenetetramine (TETA), a Cu²⁺-selective chelator, improves cardiac function in diabetic patients, and in rats with heart disease; the latter displayed ∼3-fold elevations in free Cu²⁺ in the coronary effluent when TETA was infused into their coronary arteries. To further study the nature of defective cardiac Cu regulation in diabetes, we employed an isolated-perfused, working-heart model in which we infused micromolar doses of Cu²⁺ into the coronary arteries and measured acute effects on cardiac function in diabetic and non-diabetic-control rats. Infusion of CuCl₂ solutions caused acute dose-dependent cardiac dysfunction in normal hearts. Several measures of baseline cardiac function were impaired in diabetic hearts, and these defects were exacerbated by low-micromolar Cu²⁺ infusion. The response to infused Cu²⁺ was augmented in diabetic hearts, which became defective at lower infusion levels and underwent complete pump failure (cardiac output = 0 ml/min) more often (P acute effects on cardiac function of pathophysiological elevations in coronary Cu²⁺. The effects of Cu²⁺ infusion occur within minutes in both control and diabetic hearts, which suggests that they are not due to remodelling. Heightened sensitivity to the acute effects of small elevations in Cu²⁺ could contribute substantively to impaired cardiac function in patients with diabetes and is thus identified as a new mechanism of heart disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. A cross-sectional international survey of continuous subcutaneous insulin infusion in 377 children and adolescents with type 1 diabetes mellitus from 10 countries

    NARCIS (Netherlands)

    Danne, T; Battelino, T; Kordonouri, O; Hanas, R; Klinkert, C; Ludvigsson, J; Barrio, R; Aebi, C; Gschwend, S; Mullis, PE; Schumacher, U; Zumsteg, U; Morandi, A; Rabbone, [No Value; Cherubini, [No Value; Toni, S; de Beaufort, C; Hindmarsh, P; Sumner, A; van Waarde, WM; van den Berg, N; Phillip, M

    2005-01-01

    Objective: To document current practices using continuous subcutaneous insulin infusion (CSII) by downloading electronically the 90-d pump data held within the pump memory and relating that to clinical data from children and adolescents in different pediatric diabetes centers from Europe and Israel.

  16. Acceptance for Beneficial Use Pumping Instrumentation and Control Skid ''M''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document is a Final Acceptance for Beneficial Use (ABU) for the readiness of Pumping Instrumentation and Control (PIC) skid ''M''. All the testing and documentation for PIC skid ''M'' is completed and the skid is ready for use in the field for pumping of tank U-102

  17. Pump and Flow Control Subassembly of Thermal Control Subsystem for Photovoltaic Power Module

    Science.gov (United States)

    Motil, Brian; Santen, Mark A.

    1993-01-01

    The pump and flow control subassembly (PFCS) is an orbital replacement unit (ORU) on the Space Station Freedom photovoltaic power module (PVM). The PFCS pumps liquid ammonia at a constant rate of approximately 1170 kg/hr while providing temperature control by flow regulation between the radiator and the bypass loop. Also, housed within the ORU is an accumulator to compensate for fluid volumetric changes as well as the electronics and firmware for monitoring and control of the photovoltaic thermal control system (PVTCS). Major electronic functions include signal conditioning, data interfacing and motor control. This paper will provide a description of each major component within the PFCS along with performance test data. In addition, this paper will discuss the flow control algorithm and describe how the nickel hydrogen batteries and associated power electronics will be thermally controlled through regulation of coolant flow to the radiator.

  18. The effect of barium infusion rate on the diagnostic value of small bowel enteroclysis

    International Nuclear Information System (INIS)

    Oudkerk, M.; Rijke, A.M.

    1988-01-01

    Although enteroclysis may have many advantages over the conventional methods of small bowel examination, the contrast material is not always infused at a rate appropriate to gain maximum diagnostic information. In this study, 190 patients were examined by small bowell enteroclysis at five contrast infusion rates ranging from 50 to 150 ml/min using a newly designed infusion pump system. The results show that at rates above 75 ml/min, motility disturbances are masked by small bowel dilatation and paralysis, transit times are extended and morphological detail is obscured. At rates below 75 ml/min, incomplete filling of the loops renders optimal diagnostic evaluation impossible. An infusion rate of 75 ml/min was found to be optimal for initiating small bowel studies. This rate can be adjusted for individual cases when pathology or drugs affect the motility of the small bowel. 13 refs.; 5 figs.; 1 table

  19. DOES TRANEXAMIC ACID REDUCE BLOOD LOSS IN OFF-PUMP CORONARY ARTERY BYPASS?

    Directory of Open Access Journals (Sweden)

    A. Mehr-Aein

    2006-09-01

    Full Text Available Tranexamic acid is now used on a routine basis for on-pump coronary artery bypass grafting (CABG. We assessed the hemostatic effects of tranexamic acid to decrease bleeding tendency and transfusion requirements in patients undergoing off-pump coronary artery bypass surgery (OPCAB. A total of 66 patients were enrolled to elective OPCAB in a double-blind, prospective randomized study. Of these, 33 patients received tranexamic acid (15 mg/kg before the infusion of heparin and 15 mg/kg after protamin infusion, and 33 patients received only saline. Preoperative hematologic variables, postoperative bleeding and allogeneic transfusions were considered. D-dimer plasma levels were also evaluated to monitor the activation of fibrinolysis. Postoperative bleeding was significantly lower in the tranexamic acid group compared with the control group (320 ± 38 mL vs. 480 ± 75 mL at 12 hour, P < 0.001. The tranexamic acid group had significantly lesser need for allogeneic blood products (0.46 units/patients vs. 0.94 units/patients, P < 0.001. They had also lower post-operative D-dimer plasma levels. No postoperative thrombotic complications were observed in either group. The defective hemostasis occurs even in the OPCABG. Tranexamic acid effectively reduces postoperative blood loss and the need for allogeneic blood products after OPCAB is decreased.

  20. Application of the DTC control in the photovoltaic pumping system

    International Nuclear Information System (INIS)

    Moulay-Idriss, Chergui; Mohamed, Bourahla

    2013-01-01

    Highlights: ► To improve the efficiency of PV systems, under different temperature and irradiance conditions. ► The MPPT and different control method for the induction motor were applied. ► The DTC in PV pumping system introduced and performance studied. ► The introductions of DTC in PV systems are very promising. ► Optimizing the water pumping system speed response characteristic by DTC. - Abstract: We aim to find a better control and optimization among the different functions of a solar pumping system. The photovoltaic panel can provide a maximum power only for defined output voltage and current. In addition, the operation to get the maximum power depends on the terminals of load, mostly a non-linear load like induction motor. In this work, we propose an intelligent control method for the maximum power point tracking of a photovoltaic system under variable temperature and irradiance conditions. The system was tested without maximum power point tracking, with the use of Scalar-Based control motor, but we cannot maintain the speed optimal. Next, we developed several methods for the control. Finally, we have chosen the Direct Torque Control.

  1. Design of ion-pump power supply control software system based on TCP/IP protocol

    International Nuclear Information System (INIS)

    Lin Feiyu; Huang Jijiang; Guo Yuhui; Fang Zheng; Wang Yanyu

    2009-01-01

    This paper discuss a Ion-pump Power Supply control system making use of RS232 series bus and Intranet. The system's hardware VAC800 is composed of MSP430F149 mixed-signal processors produced by TI and UA7000A network model. MSP430F149 has advantages of ultra-low-power and high-integration. The Ion-pump Power Supply control system has the characteristics of strong function, simple structure, high reliability, strong resistance of noise, no peripheral chip, etc. Visual studio 2005 is used to design the system's software. The Ion-pump Power supplier control system can remotely monitor and control Ion-pump Power Suppliers. (authors)

  2. Controlling Price-Responsive Heat Pumps for Overload Elimination in Distribution Systems

    DEFF Research Database (Denmark)

    Csetvei, Zsuzsa; Østergaard, Jacob; Nyeng, Preben

    2011-01-01

    This paper investigates the possibility of applying electric heat pumps with the control-by-price-concept in order to avoid overload in a local distribution system. The proposed control algorithm is based upon a centrally dispatched real-time market price, reflecting the state of a larger power...... system, and is extended with a local price control for overload elimination on the corresponding feeder. The paper presents the mathematical models of a two-node system with price-responsive heat pumps, the chosen methodology of the central price calculation, and the proposed local feedback control...

  3. Variable Displacement Control of the Concrete Pumping System Based on Dynamic Programming

    Directory of Open Access Journals (Sweden)

    Ye Min

    2017-01-01

    Full Text Available To solve the problems of cylinder piston striking cylinder and the hydraulic shocking of the main pump, and causing energy waste problem, the method of variable displacement control of piston stroke was proposed. In order to achieve effective control of the piston stroke, variable displacement control model was established under the physical constraint condition of non-collision between piston and cylinder. And the control process was realized by Dynamic Programming(DP, the simulation and test results show that piston of concrete pumping system don’t strike cylinder and reduce the hydraulic shock of the main pump outlet, meanwhile improve the response speed of the cylinder and achieve energy-saving purposes under varying loads. This control model built in the integration design space of structure variable and control variable is of guiding significance for solving open-loop system’s engineering problems.

  4. Evaluating the use of the Cleo 90 infusion set for patients on a palliative care unit.

    Science.gov (United States)

    Schneider, Michael; Hoffmann, Martin; Lorenzl, Stefan

    2009-08-01

    Although the use of subcutaneous infusion is common in palliative care, problems can occur. Normally, butterfly needles are used; however, there are occasional issues with patients being able to walk around or with restless patients who suffer from delirium. In these cases, needles often dislocate; therefore, a small observational study was undertaken to evaluate the use of the Cleo 90 infusion set. The use of this needle system has been well established in diabetic patients who require continuous subcutaneous infusion of insulin, but has never been tested in a wider range of patients with other medications. In this 6-month study, 45 patients were identified for subcutaneous infusion and a total of 112 needles were used for this study, since we initially changed each site after 2 days to control the local site for adverse reactions. We have not observed any complications with drug combinations delivered via the attached tube and the needle, and have used up to five different drugs mixed together in a single syringe. Needles could be used for a mean time of 5 +/- 2 days (range 2-12 days). Local site reactions have been observed only with sodium chloride infusions, which were not delivered via a pump system. Reddening and induration of the skin occurred, but they were reversible after removing the needle. As this was a small study in only one unit, without standardization the results can only be observational. However, it has shown, for the first time, that the Cleo 90 needle can be safe and comfortable.

  5. Accuracy of a new patch pump based on a microelectromechanical system (MEMS) compared to other commercially available insulin pumps: results of the first in vitro and in vivo studies.

    Science.gov (United States)

    Borot, Sophie; Franc, Sylvia; Cristante, Justine; Penfornis, Alfred; Benhamou, Pierre-Yves; Guerci, Bruno; Hanaire, Hélène; Renard, Eric; Reznik, Yves; Simon, Chantal; Charpentier, Guillaume

    2014-11-01

    The JewelPUMP™ (JP) is a new patch pump based on a microelectromechanical system that operates without any plunger. The study aimed to evaluate the infusion accuracy of the JP in vitro and in vivo. For the in vitro studies, commercially available pumps meeting the ISO standard were compared to the JP: the MiniMed® Paradigm® 712 (MP), Accu-Chek® Combo (AC), OmniPod® (OP), Animas® Vibe™ (AN). Pump accuracy was measured over 24 hours using a continuous microweighing method, at 0.1 and 1 IU/h basal rates. The occlusion alarm threshold was measured after a catheter occlusion. The JP, filled with physiological serum, was then tested in 13 patients with type 1 diabetes simultaneously with their own pump for 2 days. The weight difference was used to calculate the infused insulin volume. The JP showed reduced absolute median error rate in vitro over a 15-minute observation window compared to other pumps (1 IU/h): ±1.02% (JP) vs ±1.60% (AN), ±1.66% (AC), ±2.22% (MP), and ±4.63% (OP), P pumps: 21 (19; 25) minutes vs 90 (85; 95), 58 (42; 74), and 143 (132; 218) minutes (AN, AC, MP), P pumps (-2.2 ± 5.6% vs -0.37 ± 4.0%, P = .25). The JP was found to be easier to wear than conventional pumps. The JP is more precise over a short time period, more sensitive to catheter occlusion, well accepted by patients, and consequently, of potential interest for a closed-loop insulin delivery system. © 2014 Diabetes Technology Society.

  6. Hemodynamic effects of rapid and slow infusions of manganese chloride and gadolinium-DTPA in dogs

    International Nuclear Information System (INIS)

    Slutsky, R.A.; Peterson, T.; Strich, G.; Brown, J.J.

    1985-01-01

    The acute hemodynamic effects of two paramagnetic contrast materials, manganese chloride and gadolinium-DTPA, were examined in dogs using ultrasonic dimension gauge crystals. Slow infusions (more than 15 minutes) of MnCl 2 or Gd-DTPA via an infusion pump had no significant hemodynamic effects. When given in just over 1 minute, Gd-DTPA produced elevated left ventricular (LV) end diastolic pressure and minor dilation of the ventricle and slowed diastolic filling. MnCl 2 , given rapidly, reduced systemic vascular resistance, resulting in hypotension. With both agents, these side effects waned after 5-10 minutes. It is concluded that both Gd-DTPA and MnCl 2 can be given safely in 0.1-mm/kg doses when administered as a slow, continuous infusion. Slow, intravenous infusion of Gd-DTPA or MnCl 2 is likely to be tolerated well by even severely ill individuals

  7. Neural network-based control of an intelligent solar Stirling pump

    International Nuclear Information System (INIS)

    Tavakolpour-Saleh, A.R.; Jokar, H.

    2016-01-01

    In this paper, an ANN (artificial neural network) control system is applied to a novel solar-powered active LTD (low temperature differential) Stirling pump. First, a mathematical description of the proposed Stirling pump is presented. Then, optimum operating frequencies of the converter corresponding to different operating conditions (i.e. different sink and source temperatures and water heads) are investigated using the proposed mathematical framework. It is found that the proposed complex mathematical scheme has a very slow convergence and thus, is not appropriate for real-time implementation of the model-based controller. Consequently, a NN (neural network) model with a lower complexity is proposed to learn the simulation data obtained from the mathematical model. The designed neural network controller is thus applied to a digital processor to effectively tune the converter frequency so that a maximum output power is acquired. Finally, the performance of the proposed mechatronic system is evaluated experimentally. The experimental results clearly demonstrate the feasibility of pumping water at low temperature difference under variable operating conditions using the proposed intelligent Stirling converter. - Highlights: • A novel intelligent solar-powered active LTD Stirling pump was introduced. • A neural network controller was used to tune the converter speed. • The intelligent converter was able to adapt itself to different operating conditions. • It was possible to excite the water column with its resonance mode. • Experimental results showed the effectiveness of the proposed converter.

  8. Treatment of idiopathic hypogonadotropic hypogonadism in men with luteinizing hormone-releasing hormone: a comparison of treatment with daily injections and with the pulsatile infusion pump.

    Science.gov (United States)

    Shargil, A A

    1987-03-01

    Thirty husbands in childless couples, aged 24 to 35 years, were treated with luteinizing hormone-releasing hormone (LH-RH) for idiopathic hypogonadotropic hypogonadism (IHH) of peripubertal (incomplete) type. They were azoospermic or oligospermic, with less than 1.5 X 10(6)/ml nonmotile spermatozoa. The diagnosis of IHH was based on clinical and laboratory features and testicular biopsy specimen study and was further supported by results of stimulation tests and gonadotropin-releasing hormone (GnRH) test. Two treatment modalities were used: subcutaneous injections of 500 micrograms LH-RH twice daily; and perpetual subcutaneous injection, via portable infusion pump, of 25 ng/kg LH-RH, at 90-minute intervals. Two patients required a short second period of pulsatile treatment to cause a second pregnancy of their spouses. The pump proved to yield better results, compared with intermittent injections, in respect to endocrine responses, spermatogenesis, and fertility capacity. Normal levels of luteinizing hormone and follicle-stimulating hormone were reached in 2 to 3 weeks and normal testosterone levels in 8 to 10 weeks from the start of treatment. Sperm counts rose to greater than 60 X 10(6)/ml viable spermatozoa with less than 15% of abnormal forms in 3 to 5 months, and the wives conceived. Of a total of 18 deliveries of healthy infants, 12 offspring were identified genetically with their fathers. Four women were still pregnant at the conclusion of the study. The pump was well tolerated, without special operational problems to the patients. Pulsatile treatment is therefore recommended in the treatment of well-diagnosed and carefully selected cases of incomplete IHH.

  9. Adaptive sliding mode back-stepping pitch angle control of a variable-displacement pump controlled pitch system for wind turbines.

    Science.gov (United States)

    Yin, Xiu-xing; Lin, Yong-gang; Li, Wei; Liu, Hong-wei; Gu, Ya-jing

    2015-09-01

    A variable-displacement pump controlled pitch system is proposed to mitigate generator power and flap-wise load fluctuations for wind turbines. The pitch system mainly consists of a variable-displacement hydraulic pump, a fixed-displacement hydraulic motor and a gear set. The hydraulic motor can be accurately regulated by controlling the pump displacement and fluid flows to change the pitch angle through the gear set. The detailed mathematical representation and dynamic characteristics of the proposed pitch system are thoroughly analyzed. An adaptive sliding mode pump displacement controller and a back-stepping stroke piston controller are designed for the proposed pitch system such that the resulting pitch angle tracks its desired value regardless of external disturbances and uncertainties. The effectiveness and control efficiency of the proposed pitch system and controllers have been verified by using realistic dataset of a 750 kW research wind turbine. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Piezoelectric-hydraulic pump based band brake actuation system for automotive transmission control

    Science.gov (United States)

    Kim, Gi-Woo; Wang, K. W.

    2007-04-01

    The actuation system of friction elements (such as band brakes) is essential for high quality operations in modern automotive automatic transmissions (in short, ATs). The current band brake actuation system consists of several hydraulic components, including the oil pump, the regulating valve and the control valves. In general, it has been recognized that the current AT band brake actuation system has many limitations. For example, the oil pump and valve body are relatively heavy and complex. Also, the oil pumps induce inherently large drag torque, which affects fuel economy. This research is to overcome these problems of the current system by exploring the utilization of a hybrid type piezo-hydraulic pump device for AT band brake control. This new actuating system integrates a piezo-hydraulic pump to the input of the band brake. Compared with the current systems, this new actuator features much simpler structure, smaller size, and lower weight. This paper describes the development, design and fabrication of the new stand-alone prototype actuator for AT band brake control. An analytical model is developed and validated using experimental data. Performance tests on the hardware and system simulations utilizing the validated model are performed to characterize the new prototype actuator. It is predicted that with increasing of accumulator pressure and driving frequency, the proposed prototype actuating system will satisfy the band brake requirement for AT shift control.

  11. In-depth interviews of patients with primary immunodeficiency who have experienced pump and rapid push subcutaneous infusions of immunoglobulins reveal new insights on their preference and expectations

    Directory of Open Access Journals (Sweden)

    Cozon GJN

    2018-03-01

    Full Text Available Grégoire Jacques Noël Cozon,1 Pierre Clerson,2 Annaïk Dokhan,3 Yann Fardini,2 Taylor Pindi Sala,4 Jean-Charles Crave4 1Department of Clinical Immunology and Rheumatology, Edouard Herriot Hospital, Lyon, France; 2Soladis Clinical Studies, Roubaix, France; 3KPL, Paris, France; 4Octapharma France, Boulogne, France Purpose: Patients with primary immunodeficiency (PID often receive immunoglobulin replacement therapy (IgRT. Physicians and patients have the choice between various methods of administration. For subcutaneous immunoglobulin infusions, patients may use an automated pump (P or push the plunger of a syringe (rapid push [RP]. P infusions are performed once a week and last around 1 hour. RP decreases the duration of administration, but requires more frequent infusions.Patients and methods: Eight out of 30 patients (coming from a single center who had participated in the cross-over, randomized, open-label trial comparing P and RP participated in a focus group or underwent in-depth interviews. Patients had a long history of home-based subcutaneous immunoglobulin using P. The trial suggested that RP had slightly greater interference on daily life than P, but similar efficacy and better cost-effectiveness. When asked about the delivery method they had preferred, around one-third of patients pointed out RP rather than P. In-depth interviews may reveal unforeseen reasons for patients’ preferences. Results: Interviews underlined the complexity of the relationship that the patients maintain with their disease and IgRT. Even if they recognized the genetic nature of the disease and claimed PID was a part of them, patients tried not to be overwhelmed by the disease. IgRT by P was well integrated in patients’ routine. By contrast, RP too frequently reminded the patients of their disease. In addition, some patients pointed out the difficulty of pushing the plunger due to the viscosity of the product. Coming back too frequently, RP was not perceived

  12. Infusion of the solid coal using pressure independent valves to regulate flow

    Energy Technology Data Exchange (ETDEWEB)

    Goretz, H G; Betting, K

    1979-01-01

    In order to improve infusion into the solid coal, attempts were made to effect this through several holes using a single pump; however, the regulation of the quantity of water directed into each hole by a ball-valve tap connected to the injection pump was shown to lack precision - gives the causes of this defect. Satisfactory regulation was obtained by means of pressure- independent flow valves which operate on the principle of hydrodynamic pressure balance; describes method of operation. Underground tests proved satisfactory even with large pressure variations. The problem of dirt penetration during down times was eliminated by installing a check valve. The system proves economical to run.

  13. Bupivacaine constant continuous surgical wound infusion versus continuous epidural infusion for post cesarean section pain, randomized placebo-controlled study

    Directory of Open Access Journals (Sweden)

    Hossam A. ELShamaa

    2016-10-01

    Conclusion: The current study demonstrated that bupivacaine administered by continuous epidural infusion provided a significantly lower pain scores with mobilization, and hence better analgesia for post cesarean section pain in the first postoperative day compared to continuous bupivacaine wound infusion through fenestrated catheter using the constant flow PainFusor system.

  14. Part-load pumping operation, control and behaviour

    International Nuclear Information System (INIS)

    1988-01-01

    Twenty one papers are printed. Their main concern is with pump performance under abnormal operating conditions or when operating at part-load. The effect of part-load operation on pump performance, pump internal flow and pump cavitation and noise were considered. The pumps considered are used in a variety of situations and some case studies were discussed. One paper about part-load operation of the boiler pumps for French pressurized water reactors and one paper on pressure pulsations of centrifugal pumps at very low flowrate, are indexed separately. (U.K.)

  15. Pumps for nuclear facilities

    International Nuclear Information System (INIS)

    1999-01-01

    The guide describes how the Finnish Radiation and Nuclear Safety Authority (STUK) controls pumps and their motors at nuclear power plants and other nuclear facilities. The scope of the control is determined by the Safety Class of the pump in question. The various phases of the control are: (1) review of construction plan, (2) control of manufacturing, and construction inspection, (3) commissioning inspection, and (4) control during operation. STUK controls Safety Class 1, 2 and 3 pumps at nuclear facilities as described in this guide. STUK inspects Class EYT (non-nuclear) pumps separately or in connection with the commissioning inspections of the systems. This guide gives the control procedure and related requirements primarily for centrifugal pumps. However, it is also applied to the control of piston pumps and other pump types not mentioned in this guide

  16. A novel technology for control of variable speed pumped storage power plant

    Institute of Scientific and Technical Information of China (English)

    Seyed Mohammad Hassan Hosseini; Mohammad Reza Semsar

    2016-01-01

    Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control (DTFC) of a variable speed pumped storage power plant (VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP’s control strategies is studied. At the first, a wind turbine with the capacity 2.2 kW and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts (including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter (2LVSC) and three-level voltage source converter (3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion (THD) and ripple of rotor torque and flux.

  17. Infusion cisternography

    International Nuclear Information System (INIS)

    Magnaes, B.; Rootwelt, K.; Sjaastad, O.

    1976-01-01

    A source of error in cerebrospinal fluid (CSF) infusion tests is leakage at the dural puncture site. The addition of a bolus of radionuclide to the infusion fluid was helpful in detecting the existence of leakage as shown by increased infusion pressure in six of eight patients studied with and without scintigraphic evidence of leakage. Comparison of CSF dynamics in 26 patients studied by infusion cisternography and conventional cisternography showed similar patterns, suggesting no alteration of CSF dynamics by the artificial CSF infusion. Combining the two tests, therefore, resulted in simple identification of the leakage and saved the patient time and discomfort

  18. Reactor feedwater pump control device

    International Nuclear Information System (INIS)

    Nishiyama, Hiroyuki.

    1990-01-01

    An amount of feedwater necessary for ensuring reactor inventory after scram is ensured automatically based on the reactor output before scram of a BWR type reactor. That is, if scram should occur, a feedwater flow rate just before the scram is stored by reactor output signals. Further, the amount of feedwater required after the scram is determined based on the output of the memory. The reactor power after the scram based on a feedwater flow rate and a main steam flow rate is inputted to an integrator, to calculate and output the amount of the feedwater flow rate (1) injected after the scram for the inventory. A coast down flowrate (2) in a case of pump trip is forecast by the output signals. Automatic trip is outputted to all turbine driving feedwater pumps when the sum of (1) and (2) exceeds a necessary and sufficient amount of feedwater required for ensuring inventory. For motor driving feedwater pumps, only a portion, for example, one of the pumps is automatically started while other pumps are stopped their operation, only in this case, to prevent excess water feeding. (I.S.)

  19. A randomised controlled trial of oxytocin 5IU and placebo infusion versus oxytocin 5IU and 30IU infusion for the control of blood loss at elective caesarean section--pilot study. ISRCTN 40302163.

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2012-02-01

    OBJECTIVE: To compare the blood loss at elective lower segment caesarean section with administration of oxytocin 5IU bolus versus oxytocin 5IU bolus and oxytocin 30IU infusion and to establish whether a large multi-centre trial is feasible. STUDY DESIGN: Women booked for an elective caesarean section were recruited to a pilot randomised controlled trial and randomised to either oxytocin 5IU bolus and placebo infusion or oxytocin 5IU bolus and oxytocin 30IU infusion. We wished to establish whether the study design was feasible and acceptable and to establish sample size estimates for a definitive multi-centre trial. The outcome measures were total estimated blood loss at caesarean section and in the immediate postpartum period and the need for an additional uterotonic agent. RESULTS: A total of 115 women were randomised and 110 were suitable for analysis (5 protocol violations). Despite strict exclusion criteria 84% of the target population were considered eligible for study participation and of those approached only 15% declined to participate and 11% delivered prior to the planned date. The total mean estimated blood loss was lower in the oxytocin infusion arm compared to placebo (567 ml versus 624 ml) and fewer women had a major haemorrhage (>1000 ml, 14% versus 17%) or required an additional uterotonic agent (5% versus 11%). A sample size of 1500 in each arm would be required to demonstrate a 3% absolute reduction in major haemorrhage (from baseline 10%) with >80% power. CONCLUSION: An additional oxytocin infusion at elective caesarean section may reduce blood loss and warrants evaluation in a large multi-centre trial.

  20. Protective effects of prescription n-3 fatty acids against impairment of spatial cognitive learning ability in amyloid β-infused rats.

    Science.gov (United States)

    Hashimoto, Michio; Tozawa, Ryuichi; Katakura, Masanori; Shahdat, Hossain; Haque, Abdul Md; Tanabe, Yoko; Gamoh, Shuji; Shido, Osamu

    2011-07-01

    Deposition of amyloid β peptide (Aβ) into the brain causes cognitive impairment. We investigated whether prescription pre-administration of n-3 fatty acids improves cognitive learning ability in young rats and whether it protects against learning ability impairments in an animal model of Alzheimer's disease that was prepared by infusion of Aβ(1-40) into the cerebral ventricles of rats. Pre-administration of TAK-085 (highly purified and concentrated n-3 fatty acids containing eicosapentaenoic acid ethyl ester and docosahexaenoic acid ethyl ester) at 300 mg kg(-1) day(-1) for 12 weeks significantly reduced the number of reference memory errors in an 8-arm radial maze, suggesting that long-term administration of TAK-085 improves cognitive leaning ability in rats. After pre-administration, the control group was divided into the vehicle and Aβ-infused groups, whereas the TAK-085 pre-administration group was divided into the TAK-085 and TAK-085 + Aβ groups (TAK-085-pre-administered Aβ-infused rats). Aβ(1-40) or vehicle was infused into the cerebral ventricle using a mini osmotic pump. Pre-administration of TAK-085 to the Aβ-infused rats significantly suppressed the number of reference and working memory errors and decreased the levels of lipid peroxide and reactive oxygen species in the cerebral cortex and hippocampus of Aβ-infused rats, suggesting that TAK-085 increases antioxidative defenses. The present study suggests that long-term administration of TAK-085 is a possible therapeutic agent for protecting against Alzheimer's disease-induced learning deficiencies. This journal is © The Royal Society of Chemistry 2011

  1. Continuous indomethacin infusion may be less effective than bolus infusions for ductal closure in very low birth weight infants

    NARCIS (Netherlands)

    de Vries, NKS; Jagroep, FK; Jaarsma, AS; Elzenga, NJ; Bos, AF

    The effectiveness of continuous indomethacin (INDO) infusion versus bolus infusions for closure of patent ductus arteriosus (PDA) was investigated. The study design was an open-label case series (continuous INDO) with historic controls matched for gestational age (bolus INDO). Ductal closure rates

  2. Improvement of continuous subcutaneous insulin infusion on patients with type 2 diabetes mellitus by 3-dimensional speckle tracking echocardiography.

    Science.gov (United States)

    Luo, Hong-Xia; Zhou, Xiao-Ling; Kou, Hong-Ju; Ni, Xian-Wei; Wu, Qing; Zou, Chun-Peng; Wu, Dao-Zhu; Liu, Yong-Fang

    2018-03-01

    Three-dimensional speckle tracking echocardiography (3D-STE) was used to evaluate the improvement of continuous subcutaneous insulin infusion on the left ventricular (LV) systolic function of patients with type 2 diabetes mellitu (T2DM). We recruited T2DM patients (38 cases, diabetic group) and healthy volunteers (35 cases, control group) to collect LV full volume imaging. TomTec software was used for calculating LV global longitudinal strain (LVGLS), global circumferential strain (LVGCS), peak twist (LVTW), peak apical rotation (LVPAR), ejection fraction (LVEF), and torsion (LVT). All indices were re-tested 2 weeks later after intensive treatment of insulin pump. LVGLS, LVGCS, LVTW and LVPAR in diabetic group were significantly decreased than control group. LVGLS and LVGCS in pre-treatment diabetic group were significantly increased than post-treatment. LVGLS, LVGCS, LVTW and LVPAR had correlations among control, pre-treatment and post-treatment diabetic groups. There were no significant differences in LVEDV, LVESV, LVEF, LVT and R-R. LV systolic function of patients with T2DM complicated with microangiopathy was improved after treatment of continuous subcutaneous insulin infusion. In addition, therapeutic effect could be accurately evaluated by 3D-STE which had vital clinical application.

  3. Neuroprotective Effects of Pomegranate Peel Extract after Chronic Infusion with Amyloid-β Peptide in Mice

    Science.gov (United States)

    Morzelle, Maressa Caldeira; Salgado, Jocelem Mastrodi; Telles, Milena; Mourelle, Danilo; Bachiega, Patricia; Buck, Hudson Sousa

    2016-01-01

    Alzheimer’s disease is a chronic and degenerative condition that had no treatment until recently. The current therapeutic strategies reduce progression of the disease but are expensive and commonly cause side effects that are uncomfortable for treated patients. Functional foods to prevent and/or treat many conditions, including neurodegenerative diseases, represent a promising field of study currently gaining attention. To this end, here we demonstrate the effects of pomegranate (Punica granatum) peel extract (PPE) regarding spatial memory, biomarkers of neuroplasticity, oxidative stress and inflammation in a mouse model of neurodegeneration. Male C57Bl/6 mice were chronically infused for 35 days with amyloid-β peptide 1–42 (Aβ) or vehicle (control) using mini-osmotic pumps. Another group, also infused with Aβ, was treated with PPE (p.o.– βA+PPE, 800 mg/kg/day). Spatial memory was evaluated in the Barnes maze. Animals treated with PPE and in the control group exhibited a reduction in failure to find the escape box, a finding that was not observed in the Aβ group. The consumption of PPE reduced amyloid plaque density, increased the expression of neurotrophin BDNF and reduced the activity of acetylcholinesterase enzyme. A reduction in lipid peroxidation and in the concentration of the pro-inflammatory cytokine TNF-α was also observed in the PPE group. No hepatic lesions were observed in animals treated with PPE. In conclusion, administration of pomegranate peel extract has neuroprotective effects involving multiple mechanisms to prevent establishment and progression of the neurodegenerative process induced by infusion with amyloid-β peptide in mice. PMID:27829013

  4. A prospective, randomized, blinded-endpoint, controlled study - continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia

    Directory of Open Access Journals (Sweden)

    Joana Nunes

    Full Text Available Abstract Background: There is evidence that administration of a programmed intermittent epidural bolus (PIEB compared to continuous epidural infusion (CEI leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. Methods: In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10 mL with Ropivacaine 0.16% plus Sufentanil 10 µg, parturient were randomly assigned to one of three regimens: A - Ropivacaine 0.15% plus Sufentanil 0.2 µg/mL solution as continuous epidural infusion (5 mL/h, beginning immediately after the initial bolus; B - Ropivacaine 0.1% plus Sufentanil 0.2 µg/mL as programmed intermittent epidural bolus and C - Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10 mL/h starting 60 min after the initial bolus. Rescue boluses of 5 mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. Results: We analyzed 130 pregnants (A = 60; B = 33; C = 37. The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p = 0.83. We found a higher caesarean delivery rate in group A (56.7%; p = 0.02. No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Conclusions: Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes.

  5. Physiological control of dual rotary pumps as a biventricular assist device using a master/slave approach.

    Science.gov (United States)

    Stevens, Michael C; Wilson, Stephen; Bradley, Andrew; Fraser, John; Timms, Daniel

    2014-09-01

    Dual rotary left ventricular assist devices (LVADs) can provide biventricular mechanical support during heart failure. Coordination of left and right pump speeds is critical not only to avoid ventricular suction and to match cardiac output with demand, but also to ensure balanced systemic and pulmonary circulatory volumes. Physiological control systems for dual LVADs must meet these objectives across a variety of clinical scenarios by automatically adjusting left and right pump speeds to avoid catastrophic physiological consequences. In this study we evaluate a novel master/slave physiological control system for dual LVADs. The master controller is a Starling-like controller, which sets flow rate as a function of end-diastolic ventricular pressure (EDP). The slave controller then maintains a linear relationship between right and left EDPs. Both left/right and right/left master/slave combinations were evaluated by subjecting them to four clinical scenarios (rest, postural change, Valsalva maneuver, and exercise) simulated in a mock circulation loop. The controller's performance was compared to constant-rotational-speed control and two other dual LVAD control systems: dual constant inlet pressure and dual Frank-Starling control. The results showed that the master/slave physiological control system produced fewer suction events than constant-speed control (6 vs. 62 over a 7-min period). Left/right master/slave control had lower risk of pulmonary congestion than the other control systems, as indicated by lower maximum EDPs (15.1 vs. 25.2-28.4 mm Hg). During exercise, master/slave control increased total flow from 5.2 to 10.1 L/min, primarily due to an increase of left and right pump speed. Use of the left pump as the master resulted in fewer suction events and lower EDPs than when the right pump was master. Based on these results, master/slave control using the left pump as the master automatically adjusts pump speed to avoid suction and increases pump flow

  6. Improving the Efficiency of the Heat Pump Control System of Carbon Dioxide Heat Pump with Several Evaporators and Gas Coolers

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2016-12-01

    Full Text Available The problem of coordination of the values of the refrigerant flow through the evaporators and gas coolers of the heat pump for the simultaneous production of heat and cold is studied. The compensation of the variations of the total flow through the evaporators is implemented using the variation of the capacity of the compressor and a corresponding change in flow through the auxiliary gas cooler of the heat pump. Control system of this gas cooler is constructed using the invariance principle of the output value (outlet temperature of the heated agent with respect to perturbations on the control channel (the refrigerant flow through the gas cooler. Principle of dual-channel compensation of the disturbance and advancing signal on input of control valve of the refrigerant through the gas cooler is ensured. Due to proposed solution, the intensity of the disturbances on the flow of refrigerant is reduced. Due to proposed technical solution power consumed by the heat pump compressor drive under transients is decreased.

  7. Infusion Extractor

    Science.gov (United States)

    Chang-Diaz, Franklin R.

    1988-01-01

    Apparatus and method of removing desirable constituents from an infusible material by infusion extraction, where a piston operating in a first chamber draws a solvent into the first chamber where it may be heated, and then moves the heated solvent into a second chamber containing the infusible material, and where infusion extraction takes place. The piston then moves the solvent containing the extract through a filter into the first chamber, leaving the extraction residue in the second chamber.

  8. Associations between bolus infusion of hydrocortisone, glycemic variability and insulin infusion rate variability in critically Ill patients under moderate glycemic control

    NARCIS (Netherlands)

    van Hooijdonk, Roosmarijn T. M.; Binnekade, Jan M.; Bos, Lieuwe D. J.; Horn, Janneke; Juffermans, Nicole P.; Abu-Hanna, Ameen; Schultz, Marcus J.

    2015-01-01

    We retrospectively studied associations between bolus infusion of hydrocortisone and variability of the blood glucose level and changes in insulin rates in intensive care unit (ICU) patients. 'Glycemic variability' and 'insulin infusion rate variability' were calculated from and expressed as the

  9. Integration of Heat Pumps in Distribution Grids: Economic Motivation for Grid Control

    NARCIS (Netherlands)

    Nykamp, Stefan; Molderink, Albert; Bakker, Vincent; Toersche, Hermen; Hurink, Johann L.; Smit, Gerardus Johannes Maria

    2012-01-01

    Electric heat pumps combined with heat buffers are important elements in smart grids since they together allow to shift the consumption of electricity in time. In this paper the effects of different control algorithms for heat pumps on the investment costs for distribution grids are investigated.

  10. Integration of heat pumps in distribution grids: economic motivation for grid control

    NARCIS (Netherlands)

    Nykamp, Stefan; Molderink, Albert; Bakker, Vincent; Toersche, Hermen; Hurink, Johann L.; Smit, Gerardus Johannes Maria

    2012-01-01

    Electric heat pumps combined with heat buffers are important elements in smart grids since they together allow to shift the consumption of electricity in time. In this paper the effects of different control algorithms for heat pumps on the investment costs for distribution grids are investigated.

  11. Smart pumps and random safety audits in a Neonatal Intensive Care Unit: a new challenge for patient safety.

    Science.gov (United States)

    Bergon-Sendin, Elena; Perez-Grande, Carmen; Lora-Pablos, David; Moral-Pumarega, María Teresa; Melgar-Bonis, Ana; Peña-Peloche, Carmen; Diezma-Rodino, Mercedes; García-San Jose, Lidia; Cabañes-Alonso, Esther; Pallas-Alonso, Carmen Rosa

    2015-12-11

    Random safety audits (RSA) are a safety tool enabling prevention of adverse events, but they have not been widely used in hospitals. The aim of this study was to use RSAs to assess and compare the frequency of appropriate use of infusion pump safety systems in a Neonatal Intensive Care Unit (NICU) before and after quality improvement interventions and to analyse the intravenous medication programming data. Prospective, observational study comparing the frequency of appropriate use of Alaris® CC smart pumps through RSAs over two periods, from 1 January to 31 December 2012 and from 1 November 2014 to 31 January 2015. Appropriate use was defined as all evaluated variables being correctly programmed into the same device. Between the two periods they were established interventions to improve the use of pumps. The information recorded at the pumps with the new security system, also extracted for one year. Fifty-two measurements were collected during the first period and 160 measurements during the second period. The frequency of appropriate use was 73.13 % (117/160) in the second period versus 0 % (0/52) in the first period (p pumps in the NICU. The improvement strategies were effective for improving appropriate use and programming of the intravenous medication infusion pumps in our NICU.

  12. Early mechanism of action of arterially infused ethanol: an experimental study on the influence of infusion speed

    International Nuclear Information System (INIS)

    Han, Joon Koo

    1988-01-01

    Abdominal aortography and histopathologic examination after absolute ethanol infusion at fast (0.4cc/sec) and slow speed (0.04cc/sec) were performed on 16 rats (2 controls. 7 fast infusion group. 7 slow infusion group). Angiographic and histopathologic findings were correlated and the findings of slow and fast infusion groups were studied. The results are as follows: 1. Histopathologic findings of the fast infusion group revealed wide area of glomerular and tubular collapses, obliteration of the free space between the Bowmann's capsule and glomerulus, sloughing and loss of the endothelium, fresh thrombi attached to the wall, and cleavage of the muscle layer of the arteries. 2. Angiographic findings of the fast infusion group revealed luminal irregularity, early obstruction of the aorta and the renal arteries, and delayed circulation time. 3. Histopathologic findings of the slow infusion group revealed degenerated, coalesced red blood cell packed in the glomeruli, focal areas of severe glomerular and tubular damage on relatively normal background, endothelial and muscular damage of the arteries. 4. Angiographic findings of the slow infusion group revealed focal perfusion defect of the kidney, delayed circulation time, and mild luminal irregularity, but there was no obstruction of the major arteries. 5. In conclusion, author believes that endothelial damage and thrombus formation from the damaged vessel wall, as well as direct cytotoxicity and in situ emboli formation play a significant role in the embolic effect of absolute ethanol.

  13. A circuit scheme to control current surge for RFID-NVM pumps

    Energy Technology Data Exchange (ETDEWEB)

    Li Ming; Kang Jinfeng; Wang Yangyuan [Institute of Microelectronics, Peking University, Beijing 100871 (China); Yang Liwu, E-mail: prettynecess@163.co [Semiconductor Manufacturing International Corporation, Shanghai 201203 (China)

    2010-02-15

    This paper presents a new circuit scheme to control the current surge in the boosting phase of an radio frequency idenfication-nonvolative memory pump. By introducing a circuit block consisting of a current reference and a current mirror, the new circuit scheme can keep the period-average current of the pump constantly below the desired level, for example, 2.5 {mu}A. Therefore, it can prevent the rectified supply of the RFID tag IC from collapsing in the boosting phase of the pump. The presented scheme could effectively reduce the voltage drop on the rectified supply from more than 50% to even zero, but could cost less area. Moreover, an analytical expression to calculate the boosting time of a pump in the new scheme is developed. (semiconductor integrated circuits)

  14. A circuit scheme to control current surge for RFID-NVM pumps

    International Nuclear Information System (INIS)

    Li Ming; Kang Jinfeng; Wang Yangyuan; Yang Liwu

    2010-01-01

    This paper presents a new circuit scheme to control the current surge in the boosting phase of an radio frequency idenfication-nonvolative memory pump. By introducing a circuit block consisting of a current reference and a current mirror, the new circuit scheme can keep the period-average current of the pump constantly below the desired level, for example, 2.5 μA. Therefore, it can prevent the rectified supply of the RFID tag IC from collapsing in the boosting phase of the pump. The presented scheme could effectively reduce the voltage drop on the rectified supply from more than 50% to even zero, but could cost less area. Moreover, an analytical expression to calculate the boosting time of a pump in the new scheme is developed. (semiconductor integrated circuits)

  15. Constant infusion of 15O-labeled water and inhalation of 11C-labeled carbon monoxide for the regional determination of pulmonary water by positron emission tomography

    International Nuclear Information System (INIS)

    Meyer, G.J.; Schober, O.; Hundeshagen, H.

    1983-01-01

    A method was developed for the continuous infusion of 15 O-labeled water which allows the tomographic reconstruction of the total lung water (TLW). Subsequent inhalation of 11 C-labeled carbon-monoxide permits the reconstruction of the blood volume (BV). After normalization of intravascular activities the difference of TLW minus BV yields a quantitative value of regional extravascular lung water (rELW). 15 O-O 2 is converted on-line to 15 O-H 2 O and trapped in a 2 ml buffer reservoir which is fed by a pump with 0.9% NaCl. A precision pump is used to withdraw the labeled H 2 O and infuse it at a rate of 6 ml/min. The radioactivity level of the indusate (ca. 3.7 MBq/sec) is controlled and can be kept constant with a deviation of less than 5% over 40 min. The sterility and apyrogenicity of the system effluent is assured by frequent bacteriological, rabbit and limulus tests. A constant radioactivity level in the lung area is reached after 8-10 min. The infusion is continued for the tomographic reconstruction (Positron Camera System 4200, Cyclotron Corp.) which takes 15 min. A fast change of cyclotron parameters (MC-36, Scanditronix) and automated chemistry procedures allow a single breath administration of 11 C-CO (ca. 40 MBq) 15 min after the end of the 15 O-H 2 O infusion. Blood pool equilibrium is reached after 3-4 min, and the blood volume is reconstructed within 15 min also. Intravascular activites as determined from reconstructed slices in the region of the aortic arch correlate linearly with blood sample activities up to 100 kBq/ml. (orig.) [de

  16. Ultrastructural study on the effects of retrograde infusion of water-soluble contrast medium the rabbit submandibular gland

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Park, Tae Won

    1987-01-01

    The author observed the effects of retrograde infusion of water soluble contrast media (Telebrix 30) on the rabbit submandibular glands and compared the effects of different degrees of filling. 26 rabbit were divided into 2 group of 1 2 each as experimental and 1 group of 2 as normal controls. One experimental group was filed with 0.2 ml and the other with 0.4 ml. Right submandibular gland of each rabbit was infused with contrast media and left one with physiologic saline as a ex perimental control, at a constant rate of 0.12 ml/min. Using an infusion pump via the main excretory duct. Immediately after the inclusion of contrast media, oblique lateral radiographs of the glands were made with occlusal film in order to confirm the glandular filling. The rabbit were sacrificed after varying periods (1, 8, 24 hours and 3, 6, 10 days) and the tissues were prepared for light and electron microscopic examination. The results were as follows: 1. In glands filled with 0.2 ml contrast media, the initial changes were a few vacuole formation in the acini and slight dilation of the intralobular duct. The moderately severe changes such as vacuole formation in the acini, the abnormal substructure within the secretory granule, dilation of acinar and intercalated duct lumen, scalloping of striated duct lumen and inflammatory cell infiltrate were observed at 3 days. The general appearance was successively recovered, so the tissue had a normal appearance at 10 days. 2. In glands filled with 0.4 ml contrast media, the most prominent alterations such as severe acinar atrophy, decreased number of secretory granules, proliferation of connective tissue stroma and pronounced inflammatory cell infiltrates appeared at 6 days. Although the general appearance returned to be almost normal at 10 days, acinar cells showed some atrophy and decreased secretory granules. 3. In glands subjected to 0.4 ml infusion, the alterations were more severe and recovery was slower than those seen in the glands

  17. In-depth interviews of patients with primary immunodeficiency who have experienced pump and rapid push subcutaneous infusions of immunoglobulins reveal new insights on their preference and expectations.

    Science.gov (United States)

    Cozon, Grégoire Jacques Noël; Clerson, Pierre; Dokhan, Annaïk; Fardini, Yann; Sala, Taylor Pindi; Crave, Jean-Charles

    2018-01-01

    Patients with primary immunodeficiency (PID) often receive immunoglobulin replacement therapy (IgRT). Physicians and patients have the choice between various methods of administration. For subcutaneous immunoglobulin infusions, patients may use an automated pump (P) or push the plunger of a syringe (rapid push [RP]). P infusions are performed once a week and last around 1 hour. RP decreases the duration of administration, but requires more frequent infusions. Eight out of 30 patients (coming from a single center) who had participated in the cross-over, randomized, open-label trial comparing P and RP participated in a focus group or underwent in-depth interviews. Patients had a long history of home-based subcutaneous immunoglobulin using P. The trial suggested that RP had slightly greater interference on daily life than P, but similar efficacy and better cost-effectiveness. When asked about the delivery method they had preferred, around one-third of patients pointed out RP rather than P. In-depth interviews may reveal unforeseen reasons for patients' preferences. Interviews underlined the complexity of the relationship that the patients maintain with their disease and IgRT. Even if they recognized the genetic nature of the disease and claimed PID was a part of them, patients tried not to be overwhelmed by the disease. IgRT by P was well integrated in patients' routine. By contrast, RP too frequently reminded the patients of their disease. In addition, some patients pointed out the difficulty of pushing the plunger due to the viscosity of the product. Coming back too frequently, RP was not perceived as time saving over a week. Long-lasting use of P could partly explain patients' reasonable reluctance to change to RP. In-depth interviews of PID patients highlighted unforeseen reasons for patients' preference that the physician needs to explore during the shared medical decision-making process.

  18. Analysis of event logs from syringe pumps: a retrospective pilot study to assess possible effects of syringe pumps on safety in a university hospital critical care unit in Germany.

    Science.gov (United States)

    Kastrup, Marc; Balzer, Felix; Volk, Thomas; Spies, Claudia

    2012-07-01

    Medication errors occur in approximately one out of five doses in a typical hospital setting. Patients in the intensive care unit (ICU) are particularly susceptible to errors during the application of intravenous drugs as they receive numerous potent drugs applied by syringe pumps. The aim of this study was to analyse the effects on potential harmful medication errors and to address factors that have potential for improving medication safety after the introduction of a standardized drug library into syringe pumps with integrated decision support systems. A team of physicians and nurses developed a dataset that defined standardized drug concentrations, application rates and alert limits to prevent accidental overdosing of intravenous medications. This dataset was implemented in 100 syringe pumps with the ability to log programming errors, alerts, reprogramming events and overrides ('smart pumps'). In this retrospective pilot study, all pump-related transaction data were obtained from the pump logs, by downloading the data from the pumps, covering 20 months of use between 1 April 2008 and 30 November 2009. Patient data were gathered from the electronic patient charts. The study was performed in a cardiothoracic ICU of the Charité University Hospital, Berlin, Germany. A total of 7884 patient treatment days and 133,601 infusion starts were evaluated. The drug library with the features of the dose rate was used in 92.8% of the syringe pump starts, in 1.5% of the starts a manual dosing mode without the use of the drug library was used and in 5.7% of the starts the mode 'mL/h', without any calculation features, was used. The most frequently used drugs were vasoactive drugs, followed by sedation medication. The user was alerted for a potentially harmful overdosing in 717 cases and in 66 cases the pumps were reprogrammed after the alert. During the early morning hours a higher rate of alarms was generated by the pumps, compared with the rest of the day. Syringe pumps with

  19. Low-Cost Control System Built Upon Consumer-Based Electronics For Supervisory Control Of A Gas-Operated Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Wetherington Jr, G Randall [ORNL; Vineyard, Edward Allan [ORNL; Mahderekal, Isaac [ORNL; Abu-Heiba, Ahmad [ORNL

    2017-06-01

    A preliminary evaluation of the performance of a consumer-based control system was conducted by the Oak Ridge National Laboratory (ORNL) and Southwest Gas as part of a cooperative research and development agreement (CRADA) authorized by the Department of Energy (DOE) (Mahderekal et al. (2013). The goal of the research was to evaluate the low-cost approach as a solution for implementing a supervisory control system for a residential gas-operated heat pump. The design incorporated two consumer-based micro-controllers; the Arduino Mega-2650 and the BeagleBone (white). Ten five-ton heat pump systems were designed, fabricated, and operationally tested in the Las Vega NV region. A robust data set was produced that allowed detailed assessment of the reliability and the operational perfromance of the newly developed control system. Experiences gained from the test provided important points of improvement for subsequent evolution of the heat pump technology.

  20. Controlling the optical bistability and multistability in a two-level pumped-probe system

    International Nuclear Information System (INIS)

    Mahmoudi, Mohammad; Sahrai, Mostafa; Masoumeh Mousavi, Seyede

    2010-01-01

    We study the behavior of the optical bistability (OB) and multistability (OM) in a two-level pumped-probe atomic system by means of a unidirectional ring cavity. We show that the optical bistability in a two-level atomic system can be controlled by adjusting the intensity of the pump field and the detuning between two fields. We find that applying the pumping field decreases the threshold of the optical bistability.

  1. A prospective, randomized, blinded-endpoint, controlled study - continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia.

    Science.gov (United States)

    Nunes, Joana; Nunes, Sara; Veiga, Mariano; Cortez, Mara; Seifert, Isabel

    2016-01-01

    There is evidence that administration of a programmed intermittent epidural bolus (PIEB) compared to continuous epidural infusion (CEI) leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10mL with Ropivacaine 0.16% plus Sufentanil 10μg, parturient were randomly assigned to one of three regimens: A - Ropivacaine 0.15% plus Sufentanil 0.2μg/mL solution as continuous epidural infusion (5mL/h, beginning immediately after the initial bolus); B - Ropivacaine 0.1% plus Sufentanil 0.2μg/mL as programmed intermittent epidural bolus and C - Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10mL/h starting 60min after the initial bolus. Rescue boluses of 5mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. We analyzed 130 pregnants (A=60; B=33; C=37). The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p=0.83). We found a higher caesarean delivery rate in group A (56.7%; p=0.02). No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  2. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid ''L''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''L''. The Appendices contains copies of the printouts of these software programs

  3. A randomised controlled trial of two infusion rates to decrease reactions to antivenom.

    Directory of Open Access Journals (Sweden)

    Geoffrey K Isbister

    Full Text Available BACKGROUND: Snake envenoming is a major clinical problem in Sri Lanka, with an estimated 40,000 bites annually. Antivenom is only available from India and there is a high rate of systemic hypersensitivity reactions. This study aimed to investigate whether the rate of infusion of antivenom reduced the frequency of severe systemic hypersensitivity reactions. METHODS AND FINDINGS: This was a randomized comparison trial of two infusion rates of antivenom for treatment of non-pregnant adult patients (>14 y with snake envenoming in Sri Lanka. Snake identification was by patient or hospital examination of dead snakes when available and confirmed by enzyme-immunoassay for Russell's viper envenoming. Patients were blindly allocated in a 11 randomisation schedule to receive antivenom either as a 20 minute infusion (rapid or a two hour infusion (slow. The primary outcome was the proportion with severe systemic hypersensitivity reactions (grade 3 by Brown grading system within 4 hours of commencement of antivenom. Secondary outcomes included the proportion with mild/moderate hypersensitivity reactions and repeat antivenom doses. Of 1004 patients with suspected snakebites, 247 patients received antivenom. 49 patients were excluded or not recruited leaving 104 patients allocated to the rapid antivenom infusion and 94 to the slow antivenom infusion. The median actual duration of antivenom infusion in the rapid group was 20 min (Interquartile range[IQR]:20-25 min versus 120 min (IQR:75-120 min in the slow group. There was no difference in severe systemic hypersensitivity reactions between those given rapid and slow infusions (32% vs. 35%; difference 3%; 95%CI:-10% to +17%;p = 0.65. The frequency of mild/moderate reactions was also similar. Similar numbers of patients in each arm received further doses of antivenom (30/104 vs. 23/94. CONCLUSIONS: A slower infusion rate would not reduce the rate of severe systemic hypersensitivity reactions from current high

  4. Cutting of Control Rod Guide Tubes and Jet Pumps at Wuergassen NPP/ Germany

    International Nuclear Information System (INIS)

    Ralf Loock

    2006-01-01

    KWW Nuclear Power Plant has been erected and put into operation in the time period 1968 to end of 1971. In 23 years of operation about 73 billions kWh electric power have been generated. The electric rated power was 670 MW. In May 1995 the decommission was started for economical reasons, since April 1997 the demolition is in progress. In autumn 2003 FANP has been called upon to cut the Control Rod Guide Tubes and Jet Pumps. After a 10 months preparatory phase, cutting of the Control Rod Guide Tubes and Jet Pumps was started in September 2004. For radiation protection reasons the Control Rod Guide Tubes and Jet Pumps were cut and packed remote controlled under water. The cutting process had been selected particularly under consideration of radiation protection aspects. A combination of the technologies band sawing and nibbling was assigned for cutting of the Control Rod Guide Tubes and Jet Pumps. The band saw consists of a substructure and of a feed system installed on it. The feed system can be equipped with one or two band saws optionally. A turntable is integrated in the substructure. It is used to support the CRGT respectively the residual piece of the CRGT and to move it out of the cut position after finishing the cutting. After getting the agreement to the specification, the equipment has been designed and manufactured according to the specification preferences. After finishing the internal testing, the factory acceptance test as well as acceptance and functional tests of every facility were carried out. After cold testing being performed successfully, the cutting equipment was installed in the NPP and checked for operational safety additionally. Cutting of the Control Rod Guide Tubes and Jet Pumps has been carried out on two working places inside the fuel element storage pool. During the total project duration on site the processing has been supervised by the radiation protection staff permanently. As a result 110 Control Rod Guide Tubes and 18 Jet Pumps were

  5. Energy management algorithm for an optimum control of a photovoltaic water pumping system

    International Nuclear Information System (INIS)

    Sallem, Souhir; Chaabene, Maher; Kamoun, M.B.A.

    2009-01-01

    The effectiveness of photovoltaic water pumping systems depends on the adequacy between the generated energy and the volume of pumped water. This paper presents an intelligent algorithm which makes decision on the interconnection modes and instants of photovoltaic installation components: battery, water pump and photovoltaic panel. The decision is made by fuzzy rules on the basis of the Photovoltaic Panel Generation (PVPG) forecast during a considered day, on the load required power, and by considering the battery safety. The algorithm aims to extend operation time of the water pump by controlling a switching unit which links the system components with respect to multi objective management criteria. The algorithm implementation demonstrates that the approach extends the pumping period for more than 5 h a day which gives a mean daily improvement of 97% of the water pumped volume.

  6. An analytical investigation on the valve and centrifugal pump speed control with a constant differential pressure across the valve

    International Nuclear Information System (INIS)

    Jung, B. R.; Joo, K. I.; Lee, B. J.; Baek, S. J.; Noh, T. S.

    2003-01-01

    A valve opening and centrifugal pump speed control was investigated analytically in a simple pumping system where the differential pressure across the control valve is maintained constant over the required flow range. The valve control program was derived analytically only as a function of the required flow rate to maintain the constant differential pressure across the valve. The centrifugal pump speed control program was also derived analytically for the required flow rate for the constant differential pressure across the control valve. These derivations theoretically show that the independent control is possible between the valve and pump speed in a system with a constant valve pressure drop. In addition, it was shown that a linear pump speed control is impossible in maintaining the constant valve pressure drop

  7. Blood glucose control in healthy subject and patients receiving intravenous glucose infusion or total parenteral nutrition using glucagon-like peptide 1

    DEFF Research Database (Denmark)

    Nauck, Michael A; Walberg, Jörg; Vethacke, Arndt

    2004-01-01

    It was the aim of the study to examine whether the insulinotropic gut hormone GLP-1 is able to control or even normalise glycaemia in healthy subjects receiving intravenous glucose infusions and in severely ill patients hyperglycaemic during total parenteral nutrition.......It was the aim of the study to examine whether the insulinotropic gut hormone GLP-1 is able to control or even normalise glycaemia in healthy subjects receiving intravenous glucose infusions and in severely ill patients hyperglycaemic during total parenteral nutrition....

  8. Achieving Outcomes With Innovative Smart Pump Technology: Partnership, Planning, and Quality Improvement.

    Science.gov (United States)

    Lehr, Jennifer; Vitoux, Rachel R; Zavotsky, Kathleen Evanovich; Pontieri-Lewis, Vicky; Colineri, Lori

    2018-04-09

    A 5-time designated Magnet academic medical center partnered with its infusion systems supplier to successfully integrate 1327 smart pumps across 45 departments with an aggressive 3-month timeline. The team also achieved quality improvement (QI) outcomes through increased drug library compliance and decreased alerts with their new technology. This large academic medical center needed to implement innovative wireless infusion pump technology in a short time frame. The approach involved a strong partnership from the medical center and the supplier, with extensive planning and collaboration among the clinical nurse specialists and consultants from both organizations to accomplish QI goals. Lean principles were also followed to enhance efficiency and accountability. Quality improvement outcomes included 100% drug library compliance across all 6 intensive care units, a decrease in pump alert rates from 4.18% to 0.79%, and a decrease in pump programming correction rate from 0.36% to 0.06%. A partnership led to a large implementation being completed efficiently across an academic medical center. Through these joint efforts, quality of care was improved within a short period of time.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  9. Depressive Symptoms, Emotion Dysregulation, and Bulimic Symptoms in Youth With Type 1 Diabetes: Varying Interactions at Diagnosis and During Transition to Insulin Pump Therapy.

    Science.gov (United States)

    Young-Hyman, Deborah L; Peterson, Claire M; Fischer, Sarah; Markowitz, Jessica T; Muir, Andrew B; Laffel, Lori M

    2016-07-01

    This study evaluated the associations between depressive symptoms, emotion dysregulation and bulimic symptoms in youth with type 1 diabetes (T1D) in the context of the diagnosis and treatment of T1D. Study participants were 103 youth in 2 distinct groups: newly diagnosed (New) or transitioning to pump therapy (continuous subcutaneous insulin infusion [CSII]; "Pump"), who completed questionnaires regarding symptoms of depression, emotion dysregulation, and bulimia. Glycemic control (A1c), height, weight, and questionnaires were evaluated within 10 days of diagnosis (n = 58) or at education/clinic visit before starting insulin utilizing CSII (n = 45). In the newly diagnosed group, only depression accounted for significant variance in bulimia scores (β = .47, P symptoms and emotion dysregulation were associated with greater bulimic symptoms. Depressive symptoms and emotion dysregulation, an indicator of poor coping/behavioral control, could help explain adoption of disordered eating behaviors in youth with T1D who are transitioning to pump therapy. © 2016 Diabetes Technology Society.

  10. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  11. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid L

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-01-03

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''L''. The Appendices contains copies of the printouts of these software programs.

  12. Natriuretic peptide infusion reduces myocardial injury during acute ischemia/reperfusion

    DEFF Research Database (Denmark)

    Kousholt, Birgitte S.; Larsen, Jens Kjærgaard Rolighed; Bisgaard, Line Stattau

    2012-01-01

    Aim: The aim of this study was to determine whether a natriuretic peptide infusion during reperfusion can reduce cardiomyocyte ischemia–reperfusion damage. Materials and methods: The effect of B-type natriuretic peptide (BNP) activity was assessed in vitro and in vivo: the cellular effect...... in apoptotic changes in the BNP-stimulated cells. Pigs tolerated the BNP and CD-NP (a CNP analogue) infusion well, with a decrease in systemic blood pressure (~15 mmHg) and increased diuresis compared with the controls. Left ventricular pressure decreased in the pigs that received BNP infusion compared...... with controls (P=0.02). A similar trend was observed in the pigs that received CD-NP infusion, although this was not significant (P=0.3). BNP and CD-NP infusion in pigs reduced total cardiac troponin T release by 46 and 40%, respectively (P=0.0015 and 0.0019), and were associated with improved RNA integrity...

  13. Natriuretic peptide infusion reduces myocardial injury during acute ischemia/reperfusion

    DEFF Research Database (Denmark)

    Kousholt, Birgitte S.; Larsen, Jens Kjærgaard Rolighed; Bisgaard, Line Stattau

    2012-01-01

    Aim: The aim of this study was to determine whether a natriuretic peptide infusion during reperfusion can reduce cardiomyocyte ischemia–reperfusion damage. Materials and methods: The effect of B-type natriuretic peptide (BNP) activity was assessed in vitro and in vivo: the cellular effect...... in apoptotic changes in the BNP-stimulated cells. Pigs tolerated the BNP and CD-NP (a CNP analogue) infusion well, with a decrease in systemic blood pressure (∼15 mmHg) and increased diuresis compared with the controls. Left ventricular pressure decreased in the pigs that received BNP infusion compared...... with controls (P=0.02). A similar trend was observed in the pigs that received CD-NP infusion, although this was not significant (P=0.3). BNP and CD-NP infusion in pigs reduced total cardiac troponin T release by 46 and 40%, respectively (P=0.0015 and 0.0019), and were associated with improved RNA integrity...

  14. Pressure management of water distribution systems via the remote real-time control of variable speed pumps

    CSIR Research Space (South Africa)

    Page, Philip R

    2017-08-01

    Full Text Available describes controllers which set the pump speed α, a physical property of the pump. The “proportional control” method (denoted PC), in analogy to the method for PCVs [2, 3, 12, 13], adjusts αi+1 = αi − kpi (Hi −Hsp) (3) where kpi is a dimension-full parameter... constant) Kpi in Eq. 6. An analogous procedure was followed for a PCV [13]. The proposed controller is called the “parameter-dependent P-controller with known constant pump flow” (DCF). The LCF and DCF controllers require Q to be known, either through a...

  15. Effect of pump limiter throat on pumping efficiency

    International Nuclear Information System (INIS)

    Ghendrih, P.; Grosman, A.; Samain, A.; Capes, H.; Morera, J.P.

    1988-01-01

    The necessary control of plasma edge density has led to the development of pump limiters to achieve this task. On Tore Supra, where a large part of the program is devoted to plasma edge studies, two types of such density control apparatus have been implemented, a set of pump limiters and the pumps associated to the ergodic divertor (magnetically assisted pump limiters). Generally two different kinds of pump limiters can be used, those with a throat which drives the plasma from the open edge plasma (SOL) to the neutralizer plate, and those without or with a very short throat. We are interested here in this aspect of the pump limiter concept, i.e. on the throat effect on neutral density build-up in the vicinity of the pumping plates (and hence on pumping efficieny). The underlying idea of this throat effect can be readily understood; indeed while the neutral capture in pump limiters without throats is only a ballistic effect, on expects the plasma to improve the efficiency of pump-limiters via plasma-neutral-sidewall interactions in the throat. This problem has been studied both numerically and analytically. The paper is divided as follows. In section 2, we describe the basic features of pump-limiters which are modelized by the numerical code Cezanne. Section 3 is devoted to the throat length effect considering in particular the neutral density profile in the throat and the neutral density buil-up as a function of the throat lenght. In section 4, we show that the plugging effect occurs for reasonnable values of throat lengths. An analytical value of the plugging length is discussed and compared to the values obtained numerically

  16. Decant pump assembly and controls qualification testing - test report

    Energy Technology Data Exchange (ETDEWEB)

    Staehr, T.W., Westinghouse Hanford

    1996-05-02

    This report summarizes the results of the qualification testing of the supernate decant pump and controls system to be used for in-tank sludge washing in aging waste tank AZ-101. The test was successful and all components are qualified for installation and use in the tank.

  17. Effect of perioperative insulin infusion on surgical morbidity and mortality

    DEFF Research Database (Denmark)

    Gandhi, Gunjan Y; Murad, M Hassan; Flynn, Errol David

    2008-01-01

    To conduct a systematic review and meta-analysis of randomized controlled trials (RCTs) to evaluate the effect of perioperative insulin infusion on outcomes important to patients.......To conduct a systematic review and meta-analysis of randomized controlled trials (RCTs) to evaluate the effect of perioperative insulin infusion on outcomes important to patients....

  18. Position Statement on the management of continuous subcutaneous insulin infusion (CSII): The Italian Lazio experience.

    Science.gov (United States)

    Maurizi, Anna R; Suraci, Concetta; Pitocco, Dario; Schiaffini, Riccardo; Tubili, Claudio; Morviducci, Lelio; Giordano, Renato; Manfrini, Silvia; Lauro, Davide; Frontoni, Simona; Pozzilli, Paolo; Buzzetti, Raffaella

    2016-01-01

    This document has been developed by a group of Italian diabetologists with extensive experience in continuous subcutaneous insulin infusion (CSII) therapy to provide indications for the clinical management of CSII in diabetic patients (both type 1 and type 2) based on delivery mode operating in Italy. Although the potential benefits of pump therapy in achieving glycemic goals is now accepted, such results cannot be obtained without specific knowledge and skills being conveyed to patients during ad hoc educational training. To ensure that these new technologies reach their full effectiveness, as demonstrated theoretically and clinically, a careful assessment of the overall therapeutic and educational process is required, in both qualitative and quantitative terms. Therefore, to ensure the cost-effectiveness of insulin pump therapy and to justify reimbursement of therapy costs by the National Health System in Italy, in this article we present a model for diabetes and healthcare centers to follow that provides for different levels of expertise in the field of CSII therapy. This model will guarantee the provision of excellent care during insulin pump therapies, thus representing the basis for a successful outcome and expansion of this form of insulin treatment in patients with diabetes while also keeping costs under control. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  19. Off-pump versus On-pump Coronary Artery Bypass Grafting in Frail Patients: Study Protocol for the FRAGILE Multicenter Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Omar Asdrúbal Vilca Mejía

    Full Text Available Abstract Introduction: Advances in modern medicine have led to people living longer and healthier lives. Frailty is an emerging concept in medicine yet to be explored as a risk factor in cardiac surgery. When it comes to CABG surgery, randomized controlled clinical trials have primarily focused on low-risk (ROOBY, CORONARY, elevated-risk (GOPCABE or high-risk patients (BBS, but not on frail patients. Therefore, we believe that off-pump CABG could be an important technique in patients with limited functional capacity to respond to surgical stress. In this study, the authors introduce the new national, multicenter, randomized, controlled trial "FRAGILE", to be developed in the main cardiac surgery centers of Brazil, to clarify the potential benefit of off-pump CABG in frail patients. Methods: FRAGILE is a two-arm, parallel-group, multicentre, individually randomized (1:1 controlled trial which will enroll 630 patients with blinded outcome assessment (at 30 days, 6 months, 1 year, 2 years and 3 years, which aims to compare adverse cardiac and cerebrovascular events after off-pump versus on-pump CABG in pre-frail and frail patients. Primary outcomes will be all-cause mortality, acute myocardial infarction, cardiac arrest with successful resuscitation, low cardiac output syndrome/cardiogenic shock, stroke, and coronary reintervention. Secondary outcomes will be major adverse cardiac and cerebrovascular events, operative time, mechanical ventilation time, hyperdynamic shock, new onset of atrial fibrillation, renal replacement therapy, reoperation for bleeding, pneumonia, length of stay in intensive care unit, length of stay in hospital, number of units of blood transfused, graft patency, rate of complete revascularization, neurobehavioral outcomes after cardiac surgery, quality of life after cardiac surgery and costs. Discussion: FRAGILE trial will determine whether off-pump CABG is superior to conventional on-pump CABG in the surgical treatment of

  20. The effect of glucagon on infusion cholangiography

    International Nuclear Information System (INIS)

    Evans, A.F.; Whitehouse, G.H.

    1979-01-01

    An assessment has been made of the effects of glucagon on biliary tract opacification during intravenous cholangiography. Two series of infusion cholangiograms were obtained at two investigating centres designated A and B. In series A, 41 patients had ioglycamide infusions at a rate of 0.2833 g min -1 over 1 h. In series B, 31 patients had ioglycamide infusions at a rate of 0.3886 g min -1 over 30 min. Radiographs were taken in both series immediately at the end of the infusion, 10 min later and 30 min after the infusion. Two mg of intravenous glucagon was injected into alternate cases in both series A and B immediately after the first radiograph was taken at the completion of the ioglycamide infusion. Two observers in each series then assessed the radiographic opacification of the biliary system without prior knowledge of which patients had received the glucagon. Delineation of the biliary system was considered better in both series in those patients who received glucagon when compared with the controls. Gallbladder opacification was definitely increased in series A in those receiving glucagon, and a similar tendency was shown in series B. The amount of contrast in the upper intestine was increased in series A in the glucagon group, but not in series B. It is concluded that glucagon improves visualisation of the biliary tract, especially the gallbladder at infusion cholangiography. (author)

  1. Effects of dexmedetomidine on heart arrhythmia prevention in off-pump coronary artery bypass surgery: A randomized clinical trial.

    Science.gov (United States)

    Soltani, Ghasem; Jahanbakhsh, Saeed; Tashnizi, Mohammad Abbasi; Fathi, Mehdi; Amini, Shahram; Zirak, Nahid; Sheybani, Shima

    2017-10-01

    Arrhythmia occurring during and after surgery is one of the major complications in open-heart surgery. Dexmedetomidine is an intravenous alpha-2 agonist and very specific short-acting drug to protect the various organs against ischemic injuries and blood reflow. However, the effect of dexmedetomidine for preventing intraoperative heart arrhythmias has not been recognized. This study aimed to determine the effect of dexmedetomidine on the incidence rate of heart arrhythmias and anesthetic required in off-pump coronary artery bypass surgery. This randomized clinical trial was conducted on patients who were candidates for off-pump coronary artery bypass referring to Imam Reza Hospital of Mashhad, Iran, from July 2016 through January 2017. The patients were randomly assigned to two groups of intervention (infusion of 0.5 mcg/kg/h dexmedetomidine together with induction followed by infusion of 0.5 mcg/kg/h by the end of the surgery) or control (saline infusion). Mean arterial pressure (MAP) and heart rate (HR) were measured before induction, during surgery operation and ICU admission. Data were analyzed by SPSS version 18 using Chi Square and independent-samples t-test. A total of 76 patients with a mean age of 59.8 ± 8.2 years (in two groups of 38) were studied. The two groups had no statistically significant difference in terms of background variables. The MAP and HR values before induction, during surgery and ICU admission were significantly higher in the control group than in the intervention group (p=0.001). Out of the studied arrhythmias, the values of PAC (55.2% vs. 15.7%), PVC (81.5% vs. 21.0%), AF (26.3% vs. 7.8%), VTAC (21.0% vs. 2.6%) were significantly lower in dexmedetomidine group (p=0.001). It seems that dexmedetomidine administration during induction and surgery can cause significant reduction in most of the common arrhythmias in off-pump coronary bypass surgery. The use of dexmedetomidine maintains MAP and HR at significantly lower values, and changes

  2. Controlled release of glaucocalyxin - a self-nanoemulsifying system from osmotic pump tablets with enhanced bioavailability.

    Science.gov (United States)

    Yanfei, Miao; Guoguang, Chen; Lili, Ren; Pingkai, Ouyang

    2017-03-01

    The purpose of this study was to develop a new formulation to enhance the bioavailability simultaneously with controlled release of glaucocalyxin A (GLA). In this study, controlled release of GLA was achieved by the osmotic release strategy taking advantage of the bioavailability enhancing capacity of self-nanoemulsifying drug delivery systems (SNEDDS). The formulation of GLA-SNEDDS was selected by the solubility and pseudoternary-phase diagrams studies. The prepared GLA-SNEDDS formulations were characterized for self-emulsification time, effect of pH and robustness to dilution, droplet size analysis and zeta potential. The optimized GLA-SNEDDS were used to prepare GLA-SNEDDS osmotic pump tablet via direct powder compression method. The effect of formulation variables on the release characteristic was investigated. GLA-SNEDDS osmotic pump tablets were administered to beagle dogs and their pharmacokinetics were compared to GLA and GLA-SNEDDS as a control. In vitro drug release studies indicated that the GLA-SNEDDS osmotic pump tablet showed sustained release profiles with 90% released within 12 h. Pharmacokinetic study showed steady blood GLA with prolonged T max and mean residence time (MRT), and enhanced bioavailability for GLA-SNEDDS osmotic pump tablet. It was concluded that simultaneous controlling on GLA release and enhanced bioavailability had been achieved by a combination of osmotic pump tablet and SNEDDS.

  3. The relationship between the hypokalaemic response to adrenaline, beta-adrenoceptors, and Na(+)-K+ pumps in skeletal and cardiac muscle membranes in the rabbit

    International Nuclear Information System (INIS)

    Elfellah, M.S.; Reid, J.L.

    1990-01-01

    The hypokalaemic response to adrenaline and the involvement of beta-adrenoceptors and Na(+)-K+ pumps were investigated in control rabbits and animals chronically pretreated with adrenaline. The hypokalaemic response to acute intravenous infusion of adrenaline was significantly reduced when rabbits were chronically pretreated with adrenaline for 10 days. Chronic pretreatment of rabbits with adrenaline significantly reduced the densities for [125I]cyanopindolol and [3H]ouabain binding sites in skeletal muscle and heart. Furthermore, there was a strong positive correlation (r = 0.97, p less than 0.001) between the Bmax for ICYP and [3H]ouabain, in the rabbit heart. Ouabain-sensitive 86Rb uptake and the activity of 3-O-methylfluorescein phosphate phosphatase were used to assess the function of the Na(+)-K+ pump in skeletal and cardiac muscle. There was no significant difference in these functional indices of the Na(+)-K+ pump between the control and adrenaline-pretreated animals, in skeletal or cardiac muscle. Thus, downregulation of the [3H]ouabain binding sites did not appear to be accompanied by reduced function of the Na(+)-K+ pump. Additional investigations are required to confirm further the dissociation between the function of the pump and the ouabain binding sites

  4. Controlling Release of Integral Lipid Nanoparticles Based on Osmotic Pump Technology.

    Science.gov (United States)

    Tian, Zhiqiang; Yu, Qin; Xie, Yunchang; Li, Fengqian; Lu, Yi; Dong, Xiaochun; Zhao, Weili; Qi, Jianping; Wu, Wei

    2016-08-01

    To achieve controlled release of integral nanoparticles by the osmotic pump strategy using nanostructured lipid carriers (NLCs) as model nanoparticles. NLCs was prepared by a hot-homogenization method, transformed into powder by lyophilization, and formulated into osmotic pump tablets (OPTs). Release of integral NLCs was visualized by live imaging after labeling with a water-quenching fluorescent probe. Effects of formulation variables on in vitro release characteristics were evaluated by measuring the model drug fenofibrate. Pharmacokinetics were studied in beagle dogs using the core tablet and a micronized fenofibrate formulation as references. NLCs are released through the release orifices of the OPTs as integral nanoparticles. Near zero-order kinetics can be achieved by optimizing the influencing variables. After oral administration, decreased C max and steady drug levels for as long as over 24 h are observed. NLC-OPTs show an oral bioavailability of the model drug fenofibrate similar to that of the core tablets, which is about 1.75 folds that of a fast-release formulation. Controlled release of integral NLCs is achieved by the osmotic pump strategy.

  5. Canadian Palliative Community Milrinone Infusions: A Case Series.

    Science.gov (United States)

    Reimche, Ruthanne; Salcedo, Daniel

    2016-01-01

    Abstract Symptom managementfor end-of-life heartfailure (HF) patients is a significant concern. Currently, Canadian practice does not support community milrinone therapy in end-of-life HF patients. Two patients had severe HF that was unresponsive to optimal medications. Further optimization and furosemide infusions were ineffective for symptom management. Both patients' symptoms were better controlled with optimal medication, furosemide, and milrinone infusions. A tailored discharge plan was developed to assist with community milrinone infusions. We discuss the challenges and successes of transitioning two patients to the community. By providing symptom management and meaningful patient and family experience, both patients were able to die in a setting of their choosing. Milrinone infusions as a bridge to end of life may improve symptoms and quality of life. Select patients may benefit from milrinone infusions with resources put in place; these end-of-life HF patients can be supported in the community.

  6. Controlled porosity solubility modulated osmotic pump tablets of gliclazide.

    Science.gov (United States)

    Banerjee, Arti; Verma, P R P; Gore, Subhash

    2015-06-01

    A system that can deliver drug at a controlled rate is very important for the treatment of various chronic diseases such as diabetes, asthma, and heart disease. Poorly water-soluble drug with pH-dependent solubility such as gliclazide (GLZ) offers challenges in the controlled-release formulation because of low dissolution rate and poor bioavailability. Solid dispersion (SD) of GLZ consisted of hydroxypropyl cellulose (HPC-SSL) as a polymeric solubilizer was manufactured by hot melt extrusion (HME) technology. Then, controlled porosity osmotic pump (CPOP) tablet of gliclazide was designed to deliver drug in a controlled manner up to 16 h. The developed formulation was optimized for type and level of pore former and coating weight gain. The optimized formulation was found to exhibit zero order kinetics independent of pH and agitation speed but depends on osmotic pressure of dissolution media indicated that mechanism of drug release was osmotic pressure. The in vivo performance prediction of developed formulation using convolution approach revealed that the developed formulation was superior to the existing marketed extended-release formulation in terms of attaining steady state plasma levels and indicated adequate exposure in translating hypoglycemic response. The prototype solubilization method combined with controlled porosity osmotic pump based technique could provide a unique way to increase dissolution rate and bioavailability of many poorly water-soluble, narrow therapeutic index drugs used in diabetes, cardiovascular diseases, etc.

  7. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid P

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describe the software programs for the Programmable Logic Controller and the Datable Access Module for Pumping Instrumentation and Control skid ''P''. The Appendices contains copies of the printouts of these software programs

  8. A simple method of injecting tumescent fluid for liposuction

    Directory of Open Access Journals (Sweden)

    Arindam Sarkar

    2011-01-01

    Full Text Available Injection of tumescent fluid is essential to obtain a painless and relatively bloodless liposuction. There are many methods of injecting the tumescent fluid like power pumps, syringes and pressure cuffs. Our method consists of applying air pressure within the plastic transfusion fluid bottle by pricking with a wide bore needle and connecting it to a sphygmomanometer balloon pump. By inflation of the balloon pump and thus increasing pressure inside the plastic bottle, the rate and volume of infusion can be controlled. By applying the cuff outside the bottle the visibility inside is impaired and the bottle gets collapsed preventing a continued pressure and thereby impairing both the quantity as well as the rate of infusion. Power pumps are expensive. This method is inexpensive, infused volume of fluid being visible and the rate of infusion controllable.

  9. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid ''M''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''M''. The Appendices contains copies of the printouts of these software programs

  10. REMOTE CONTROLLING OF AN AGRICULTURAL PUMP SYSTEM BASED ON THE DUAL TONE MULTI-FREQUENCY (DTMF TECHNIQUE

    Directory of Open Access Journals (Sweden)

    BEZA N. GETU

    2015-10-01

    Full Text Available In modern days, as a result of advances in technology, human beings are interested to remotely control different systems and applications. In this work, telephone signalling technique using Dual Tone Multi-Frequency (DTMF signalling, is used to control switching of electrical loads such as agricultural pumps located in remote areas. A DTMF tone command sent from a transmitting fixed or mobile phone terminal will be used to SWITCH ON/OFF the motors used to pump water for agricultural fields. A processing electronic system at the receiving side is designed to interpret the tone commands and sends an appropriate signal to the motor driving circuit to complete the pump switching states. In the design methodology, it is possible to control several water pumps distributed in a certain agricultural site, however, in this work we considered four pumps and the paper presents the complete electronic design and simulation results at the different stages of the design. The electronic design is based on discrete passive and active electronic components and the system is tested and simulated using Multism program. The results of the simulation show that the design is capable of controlling the switching state of the motors. For a certain DTMF command, it is possible to switch ON/OFF a specific motor pump or all of the four motors.

  11. Use of case-based reasoning to enhance intensive management of patients on insulin pump therapy.

    Science.gov (United States)

    Schwartz, Frank L; Shubrook, Jay H; Marling, Cynthia R

    2008-07-01

    This study was conducted to develop case-based decision support software to improve glucose control in patients with type 1 diabetes mellitus (T1DM) on insulin pump therapy. While the benefits of good glucose control are well known, achieving and maintaining good glucose control remains a difficult task. Case-based decision support software may assist by recalling past problems in glucose control and their associated therapeutic adjustments. Twenty patients with T1DM on insulin pumps were enrolled in a 6-week study. Subjects performed self-glucose monitoring and provided daily logs via the Internet, tracking insulin dosages, work, sleep, exercise, meals, stress, illness, menstrual cycles, infusion set changes, pump problems, hypoglycemic episodes, and other events. Subjects wore a continuous glucose monitoring system at weeks 1, 3, and 6. Clinical data were interpreted by physicians, who explained the relationship between life events and observed glucose patterns as well as treatment rationales to knowledge engineers. Knowledge engineers built a prototypical system that contained cases of problems in glucose control together with their associated solutions. Twelve patients completed the study. Fifty cases of clinical problems and solutions were developed and stored in a case base. The prototypical system detected 12 distinct types of clinical problems. It displayed the stored problems that are most similar to the problems detected, and offered learned solutions as decision support to the physician. This software can screen large volumes of clinical data and glucose levels from patients with T1DM, identify clinical problems, and offer solutions. It has potential application in managing all forms of diabetes.

  12. Speed control device for coolant recycling pump

    International Nuclear Information System (INIS)

    Kageyama, Takao.

    1992-01-01

    The present invention intends to increase a margin relative of the oscillations of neutron fluxes when the temperature of feedwater is lowered in a compulsory recycling type BWR reactor. That is, when the operation point represented by a reactor thermal power and a reactor core inlet flow rate is in a state approximate to an oscillation limit of the reactor power, the device of the present invention controls the recycling pump speed in the increasing direction depending on the lowering range of the feedwater temperature from a stationary state. With such a constitution, even if the reactor power is in the operation region near the oscillation limit in the BWR type reactor and a feedwater heating loss is caused, the speed of the coolant recycling pump is increased by 10% at the maximum depending on the extent of the reduction of the feedwater temperature, so that the oscillation of the reactor power can be prevented from lasting for a long period of time even if a reactivity external disturbance should occur in the reactor. (I.S.)

  13. Clinical Evaluation of the Use of a Multifunctional Remotely Controlled Insulin Pump

    Science.gov (United States)

    Pinget, Michel; Lachgar, Karim; Parkin, Christopher G.; Grulet, Hervé; Guillon-Metz, Françoise; Weissmann, Joerg

    2014-01-01

    Current insulin pumps now feature advanced functions for calculating insulin dosages, delivering insulin and analyzing data, however, the perceived usefulness of these functions in clinical settings has not been well studied. We assessed the use and patient perceptions of an insulin delivery system (Accu-Chek® Combo, Roche Diagnostics, Mannheim, Germany) that combines an insulin pump and a handheld multifunctional blood glucose meter with integrated remote control functions. This prospective, observational, multicenter study enrolled 74 type 1 diabetes patients within 13 weeks after starting use of the pump system. At 4 to 24 weeks, investigators collected usage data from the latest 14-day period. Seventy-two patients completed the evaluation, aged 39 ± 15 years, diabetes duration 16 ± 13 years, HbA1c 8.3 ± 1.6%. At follow-up, 62 (86.1%) patients used the remote control for ≥50% of all boluses, 20 (27.8%) used the bolus advisor for ≥50% of all boluses, and 42 (58.3%) viewed at least 1 of the e-logbook reports. More than 95% of users appraised the functions as easy-to-use and useful; median scores from VAS (0 = useless to 100 = indispensable) ranged from 72 to 85. A high percentage of study patients used the system’s advanced features, especially the remote control feature for bolusing. Overall, patients assessed the functions as useful and easy to use. Results support the implementation of these smart capabilities in further insulin pump developments. PMID:25107708

  14. A pilot study of factors associated with glycaemic control in adults with Type 1 diabetes mellitus on insulin pump therapy.

    Science.gov (United States)

    Wen, W; Frampton, R; Wright, K; Fattore, S; Shadbolt, B; Perampalam, S

    2016-02-01

    To identify the knowledge and management factors associated with glycaemic control among adults with Type 1 diabetes mellitus treated with insulin pump therapy. A cross-sectional study of adults with Type 1 diabetes mellitus on insulin pump therapy for at least 12 months (n = 50, 18-70 years old) was undertaken between December 2013 and May 2014. A new questionnaire was developed to evaluate participants' knowledge and management related to insulin pump therapy, and were correlated with insulin pump data, HbA1c and frequency of hypoglycaemia. Participants who changed their insulin pump settings when indicated had significantly better glycaemic control than those who did not (P = 0.04). Multivariate logistic regression analysis found that better overall insulin pump therapy management was a significant predictor of better glycaemic control (odds ratio 4.45, 95% confidence interval 1.61-12.3; P = 0.004) after adjusting for potential confounders including age, gender, duration of diabetes and insulin pump therapy. However, overall insulin pump therapy knowledge was not a significant predictor of glycaemic control (P = 0.058). There was no significant association between frequency of hypoglycaemia and insulin pump therapy knowledge or management. We identified some key knowledge and management factors associated with glycaemic control in adults with Type 1 diabetes mellitus on insulin pump therapy using a newly designed questionnaire. The pilot study assessed the clinical utility of this evaluation tool, which may facilitate provision of targeted education to insulin pump therapy users to achieve optimal glycaemic control. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.

  15. An observational 7-year study of continuous subcutaneous insulin infusion for the treatment of type 1 diabetes mellitus.

    Science.gov (United States)

    Papargyri, Panagiota; Ojeda Rodríguez, Sylvie; Corrales Hernández, Juan José; Mories Álvarez, María Teresa; Recio Córdova, José María; Delgado Gómez, Manuel; Sánchez Marcos, Ana Isabel; Iglesias López, Rosa Ana; Herrero Ruiz, Ana; Beaulieu Oriol, Myriam; Miralles García, José Manuel

    2014-03-01

    This work reports the experience with use of continuous subcutaneous insulin infusion (CSII) in 112 type 1 diabetic patients followed up for 7 years and previously treated with multiple daily insulin injections (MDII). A retrospective, observational study in 112 patients with diabetes mellitus treated with CSII from 2005 to 2012, previously treated with MDII and receiving individualized diabetic education with a specific protocol. Variables analyzed included: prevalence of the different indications of pump treatment; mean annual HbA1c and fructosamine values before and after CSII treatment; and hypoglycemia frequency and symptoms. The most common reason for pump treatment was brittle diabetes (74.1%), followed by frequent or severe hypoglycemia or hypoglycemia unawareness (44.6%). Other indications were irregular food intake times for professional reasons (20.2%), dawn phenomenon (15.7%), pregnancy (12.3%), requirement of very low insulin doses (8.9%), and gestational diabetes (0.9%). HbA1c decreased by between 0.6% and 0.9%, and fructosamine by between 5.1% and 12.26%. Nine percent of patients experienced hypoglycemia weekly, 24% every two weeks, and 48% monthly. No hypoglycemia occurred in 19% of patients. Only 10% had neuroglycopenic symptoms. Hypoglycemia unawareness was found in 21%. Hypoglycemia was more common at treatment start, and its frequency rapidly decreased thereafter. CSII therapy provides a better glycemic control than MDII treatment. Specific patient training and fine adjustment of insulin infusion doses are required to prevent hypoglycemic episodes, which are the most common complications, mainly at the start of treatment. Copyright © 2013 SEEN. Published by Elsevier Espana. All rights reserved.

  16. A fuzzy controller for the VASPS (Vertical Annular Separation and Pumping System) subsea separation and pumping system; Um controlador fuzzy para o sistema de separacao e bombeamento submarino - VASP (Vertical Annular Separation and Pumping System)

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Alex F.; Mendes, Jose Ricardo P.; Morooka, Celso K. [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Mecanica. Dept. de Engenharia de Petroleo; Estevam, Valdir [PETROBRAS, Rio de Janeiro, RJ (Brazil); Guilherme, Ivan R. [UNESP, Rio Claro, SP (Brazil). Inst. de Geociencias e Ciencias Exatas. Dept. de Estatistica, Matematica Aplicada e Computacao; Rigo, Jose Eduardo [Centro Federal de Educacao Tecnologica no Espirito Santo (CEFETES), Vitoria, ES (Brazil)

    2004-07-01

    In this paper the designs of a fuzzy controller for the VASPS (Vertical Annular Separation and Pumping System) liquid level and separation pressure control are presented, as well as a simulation of its work to evaluate the performance of the controller designed. The VASPS is a two-phase subsea separation and pumping system, which is made up of a separation vessel, where the mixture (liquid and gas) enters and suffers the separation process through three levels, the expansion chamber, the helix and the pool. The liquid inside the pool is taken to the platform using a pump that with a choke control the pool liquid level. The pool liquid level control is necessary because if the level exceeds the maximum value allowed, the liquid can invade the space occupied by the helix and hinder the separation process. An the other hand if the level is below the minimum allowed the pump can be damaged. The separation pressure control is important for operational security and efficiency issues, because when we keep the separation pressure near an optimum value we are maximizing its efficiency. With the controller and the simulator, many simulations of the work of system were made to get results that could be used to evaluate if the designed controller solved the problem and if its performance were satisfactory. After, a PID control system was designed to be used as comparison with the results obtained with the fuzzy controller, since the PID is widely used in the industrial environment. (author)

  17. Power consumption analysis of pump station control systems based on fuzzy controllers with discrete terms in iThink software

    Science.gov (United States)

    Muravyova, E. A.; Bondarev, A. V.; Sharipov, M. I.; Galiaskarova, G. R.; Kubryak, A. I.

    2018-03-01

    In this article, power consumption of pumping station control systems is discussed. To study the issue, two simulation models of oil level control in the iThink software have been developed, using a frequency converter only and using a frequency converter and a fuzzy controller. A simulation of the oil-level control was carried out in a graphic form, and plots of pumps power consumption were obtained. Based on the initial and obtained data, the efficiency of the considered control systems has been compared, and also the power consumption of the systems was shown graphically using a frequency converter only and using a frequency converter and a fuzzy controller. The models analysis has shown that it is more economical and safe to use a control circuit with a frequency converter and a fuzzy controller.

  18. Effect of transdermal glyceryl trinitrate and anti-inflammatory gel in infusion phlebitis.

    Science.gov (United States)

    Cökmez, Atilla; Gür, Serhat; Genç, Hüdai; Deniz, Sümer; Tarcan, Ercüment

    2003-10-01

    Phlebitis is the commonest complication of intravenous infusion. It has been suggested that it is initiated by venoconstriction at the infusion site, hence treatment with a vasodilator may reduce its incidence. A prospective controlled study was carried out on the effect of transdermal glyceryl trinitrate (GTN) and topical anti-inflammatory gel (non-steroidal anti-inflammatory drug; NSAID) on the survival of peripheral intravenous infusion in 386 patients. A total of 34.9% (43 out of 123) of the infusions failed in the control group compared with 14.1% (18 out of 127) in the NSAID group (P NSAI gel and GTN but NSAI gel is more effective than GTN.

  19. Studies on impurity control and hydrogen pumping with chromium gettering in ISX-B

    International Nuclear Information System (INIS)

    Mioduszewski, P.; Simpkins, J.E.; Edmonds, P.H.; Isler, R.C.; Lazarus, E.A.; Ma, C.H.; Murakami, M.; Wootton, A.J.

    1984-01-01

    Chromium gettering has been proven to be a trouble-free and efficient method of surface pumping in tokamaks. The impurity control capabilities are excellent and comparable to that of titanium. The hydrogen uptake is reduced to monolayer quantities on the surface. The expansion of the operating space is similar to that seen with titanium without the disadvantage of strongly increased hydrogen fluxes. Possible applications of chromium gettering are: impurity control in contemporary tokamaks; surface pumping in short pulse DT-burning devices to minimize tritium inventory, and wall conditioning of future large machines prior to operation

  20. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by ...

  1. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid M

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-14

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''M''. The Appendices contains copies of the printouts of these software programs.

  2. Operating experience with an on-line vibration control system for PWR main coolant pumps

    International Nuclear Information System (INIS)

    Runkel, J.; Stegemann, D.; Vortriede, A.

    1996-01-01

    The main circulation pumps are key components of nuclear power plants with pressurized water reactors, because the availability of the main circulation pumps has a direct influence on the availability and electrical output of the entire plant. The on-line automatic vibration control system ASMAS was developed for early failure detection during the normal operation of the main circulation pumps in order to avoid unexpected outages and to establish the possibility of preventive maintenance of the pumps. This system is permanently and successfully operating in three German 1300 MW el NPP's with PWR and has been successfully tested in a 350 MW el NPP with a PWR. (orig.)

  3. Operating experience with an on-line vibration control system for PWR main coolant pumps

    International Nuclear Information System (INIS)

    Runkel, J.; Stegemann, D.; Vortriede, A.

    1998-01-01

    The main circulation pumps are key components of nuclear power plants with pressurized water reactors (PWRs), because the availability of the main circulation pumps has a direct influence on the availability and electrical output of the entire plant. The on-line automatic vibration control system ASMAS was developed for early failure detection during the normal operation of the main circulation pumps in order to avoid unexpected outages and to establish the possibility of preventive maintenance of the pumps. This system is permanently and successfully operating in three German 1300 MW e1 NPP's with PWR and has been successfully tested in a 350 MW e1 NPP with a PWR. (orig.)

  4. Effect of a high-dose target-controlled naloxone infusion on pain and hyperalgesia in patients following groin hernia repair: study protocol for a randomized controlled trial

    DEFF Research Database (Denmark)

    Pereira, Manuel Pedro; Utke Werner, Mads; Berg Dahl, Joergen

    2015-01-01

    no volunteer developed significant secondary hyperalgesia after the placebo infusion. In order to consistently demonstrate latent sensitization in humans, a pain model inducing deep tissue inflammation, as used in animal studies, might be necessary. The aim of the present study is to examine whether a high......-dose target-controlled naloxone infusion can reinstate pain and hyperalgesia following recovery from open groin hernia repair and thus consistently demonstrate opioid-mediated latent sensitization in humans. METHODS/DESIGN: Patients submitted to unilateral, primary, open groin hernia repair will be included...

  5. Vacuum infusion manufacturing and experimental characterization of Kevlar/epoxy composites

    International Nuclear Information System (INIS)

    Ricciardi, M. R.; Giordano, M.; Antonucci, V.; Langella, A.; Nele, L.

    2014-01-01

    Epoxy/Kevlar composites have been manufactured by conventional Vacuum Infusion process and the Pulse Infusion technique. Pulse Infusion allows to control the pressure of the vacuum bag on the dry fiber reinforcement by using a proper designed pressure distributor that induces a pulsed transverse action and promotes the through thickness resin flow. The realized composite panel have been mechanically characterized by performing tensile and short beam shear tests according with the ASTM D3039 and ASTM D2344/D 2344M standard respectively in order to investigate the effect of Pulse Infusion on the tensile strength and ILSS

  6. Vacuum infusion manufacturing and experimental characterization of Kevlar/epoxy composites

    Science.gov (United States)

    Ricciardi, M. R.; Giordano, M.; Langella, A.; Nele, L.; Antonucci, V.

    2014-05-01

    Epoxy/Kevlar composites have been manufactured by conventional Vacuum Infusion process and the Pulse Infusion technique. Pulse Infusion allows to control the pressure of the vacuum bag on the dry fiber reinforcement by using a proper designed pressure distributor that induces a pulsed transverse action and promotes the through thickness resin flow. The realized composite panel have been mechanically characterized by performing tensile and short beam shear tests according with the ASTM D3039 and ASTM D2344/D 2344M standard respectively in order to investigate the effect of Pulse Infusion on the tensile strength and ILSS.

  7. TFTR ultrahigh-vacuum pumping system incorporating mercury diffusion pumps

    International Nuclear Information System (INIS)

    Sink, D.A.; Sniderman, M.

    1976-06-01

    The TFTR vacuum vessel will have a system of four 61 cm diameter mercury diffusion pumps to provide a base pressure in the 10 -8 to 10 -9 Torr range as well as a low impurity level within the vessel. The system, called the Torus Vacuum Pumping System (TVPS), will be employed with the aid of an occasional 250 0 C bakeout in situ as well as periodic applications of aggressive discharge cleaning. The TVPS is an ultrahigh-vacuum (UHV) system using no elastomers as well as being a closed system with respect to tritium or any tritiated gases. The backing system employing approximately 75 all-metal isolation valves is designed with the features of redundancy and flexibility employed in a variety of ways to meet the fundamental requirements and functions enumerated for the TVPS. Since the design, is one which is a modification of the conceptual design of the TVPS, those features which have changed are discussed. Calculations are presented for the major performance parameters anticipated for the TVPS and include conductances, effective pumping speeds, base pressures, operating parameters, getter pump parameters, and calculations of time constants associated with leak checking. Modifications in the vacuum pumping system for the guard regions on the twelve bellows sections are presented so that it is compatible with the main TVPS. The bellows pumping system consists of a mechanical pump unit, a zirconium aluminum getter pump unit and a residual gas analyzer. The control and management of the TVPS is described with particular attention given to providing both manual and automatic control at a local station and at the TFTR Central Control. Such operations as testing, maintenance, leak checking, startup, bakeout, and various other operations are considered in some detail. Various aspects related to normal pulsing, discharge cleaning, non-tritium operations and tritium operations are also taken into consideration. A cost estimate is presented

  8. An experimental study on the influence of infusion speed on the early mechanism of embolic effect of arterially infused absolute Ethanol in the rat

    International Nuclear Information System (INIS)

    Han, Joon Koo; Kim, Woo Ho; Lee, Byung Hee; Park, Kil Sun; Park, Jae Hyung; Kim, Chu Wan; Han, Man Chung

    1990-01-01

    In order to clarify the early mechanism of action of the tissue necrosis induced by intraarterially infused absolute ethanol, abdominal aortography and histopathologic examination after absolute ethanol infusion into aorta at fast (0.4ml/sec) and slow speed (0.04ml/sec) were performed on 22 rats (2 controls, 7 in fast infusion group, 7 in slow infusion group, 3 in fast and 3 in slow infusion groups during aorta compression, respectively). Histopathologic features under the light and scanning electron microscope were correlated with the angiographic findings within 30 minutes after ethanol infusion. The results are as follows : 1. In fast infusion group, histopathologic examination of the kidney showed severe glomerular and tubular damage. Extensive damage on endothelial and medial layer was noted in arteries, and fresh thrombi originated from the damaged arterial wall were seen. 2. Angiographic findings in the fast infusion group were luminal irregularity and early obstruction of large arteries. And circulation time was prolonged. 3. In slow infusion group, histopathologic examination of the kidney showed focal area of severe glomerular and tubular damage on relatively normal background. Endothelial and muscular damage was noted in arteries, but the degree of the damage was less severe than that of the fast infusion group. 4. Angiographic findings in the slow infusion group were focal perfusion defect of the kidney, delayed circulation time, and mild luminal irregularity, but obstruction of the major arteries was not seen

  9. Control device for recycling pump

    International Nuclear Information System (INIS)

    Nakajima, Yoshihiro.

    1984-01-01

    Purpose: To enable to control the recycling flow rate by the variation coefficient of the recycling flow rate corresponding to the state of the reactor power. Constitution: A number of rotation of an electric power generator for supplying a driving power to recycling pump is calculated in a rotational number setting section such that the deviation between the actual measurement signal for the flow rate of steams from the reactor and an instruction signal for the steam flow rate is reduced to zero. The velocity ratio of the fluid coupling for connecting the motor with the electric power generator is calculated in a rotational number adjusting section such that the deviation between the output signal from the setting section and the measuring signal from the electric power generator is reduced to zero, and a set velocity ratio signal is outputted. The set velocity ratio signal, set velocity ratio measurement signal from the fluid coupling and the rotational number measuring signal for the electric power generator are inputted into a velocity ratio control section to control the velocity ratio of the fluid coupling such that the deviation between both of the velocity ratio signal inputs is reduced to zero by the variation coefficient depending on the number of rotation of the electric power generator. (Sekiya, K.)

  10. The laser control system for the TRIUMF optically pumped polarized H- ion source

    International Nuclear Information System (INIS)

    Kadantsev, S.G.; Levy, C.D.P.; Mouat, M.M.

    1994-08-01

    The optically pumped polarized H - ion source at TRIUMF produces up to 100 μΑ dc of 78% polarized beam within an emittance of 1.0 π mm mrad and is now being prepared for an upcoming experiment at TRIUMF that will measure parity violation in pp scattering at 230 MeV. The optical pumping is accomplished by argon laser pumped Ti-sapphire lasers. The laser control system provides monitoring and precision control of the lasers for fast spin reversal up to 200 s -1 . To solve the problems of laser power and frequency stabilization during fast spin flipping, techniques and algorithms have been developed that significantly reduce the variation of laser frequency and power between spin states. The upgraded Faraday rotation system allows synchronous measurement of Rb thickness and polarization while spin flipping. The X Window environment provides both local and remote control to laser operators via a local area network and X window terminals. In this new environment issues such as access authorization, response time, operator interface consistency and ease of use are of particular importance. (author)

  11. The Effect of Milrinone on the Right Ventriclular Function in Patients with Reduced Right Ventricular Function Undergoing Off-pump Coronary Artery Bypass Graft Surgery

    Science.gov (United States)

    Lee, Jong Hwa; Oh, Young Jun; Shim, Yon Hee; Hong, Yong Woo; Yi, Gijong

    2006-01-01

    This investigation evaluated the effect of continuous milrinone infusion on right ventriclular (RV) function during off-pump coronary artery bypass graft (OPCAB) surgery in patients with reduced RV function. Fifty patients scheduled for OPCAB, with thermodilution RV ejection fraction (RVEF) milrinone (0.5 µg/kg/min) or control (saline) group. Hemodynamic variables and RV volumetric data measured by thermodilution method were collected as follows: after anesthesia induction (T1); 10 min after heart displacement for obtuse marginal artery anastomosis (T2); after pericardial closure (T3). Cardiac index and heart rate increased and systemic vascular resistance significantly decreased in milrinone group at T2. Initially lower RVEF of milrinone group was eventually comparable to control group after milrinone infusion. RVEF did not significantly change at T2 and T3 in both groups. RV end-diastolic volume in milrinone group consistently decreased from the baseline at T2 and T3. Continuous infusion of milrinone without a bolus demonstrated potentially beneficial effect on cardiac output and RV afterload in patients with reduced RV function during OPCAB. However, aggressive augmentation of intravascular volume seems to be necessary to maximize the effect of the milrinone in these patients. PMID:17043419

  12. Evidence for coordinate genetic control of Na,K pump density in erythrocytes and lymphocytes

    International Nuclear Information System (INIS)

    DeLuise, M.; Flier, J.S.

    1985-01-01

    The erythrocyte is widely used as a model cell for studies of the Na,K pump in health and disease. However, little is known about the factors that control the number of Na,K pumps expressed on the erythrocytes of a given individual, nor about the extent to which erythrocytes can be used to validly assess the pump density on other cell types. In this report, the authors have compared the interindividual variance of Na,K pump density in erythrocytes of unrelated individuals to that seen with identical twins. Unlike unrelated individuals, in whom pump parameters, i.e., ouabain binding sites, 86 Rb uptake, and cell Na concentration vary widely, identical twin pairs showed no significant intrapair variation for these values. Thus, a role for genetic factors is suggested. In addition, the authors established and validated a method for determining Na,K pump density and pump-mediated 86 Rb uptake in human peripheral lymphocytes. Using this method, they show that whereas Na,K pump density differs markedly between erythrocytes (mean of 285 sites per cell) and lymphocytes (mean 40,600 sites per cell), there is a strong and highly significant correlation (r = 0.79, P less than 0.001) between the pump density in these cell types in any given individual. Taken together, these studies suggest that genetic factors are important determinants of Na,K pump expression, and that pump density appears to be coordinately regulated in two cell types in healthy individuals

  13. Generic Safety Requirements for Developing Safe Insulin Pump Software

    Science.gov (United States)

    Zhang, Yi; Jetley, Raoul; Jones, Paul L; Ray, Arnab

    2011-01-01

    Background The authors previously introduced a highly abstract generic insulin infusion pump (GIIP) model that identified common features and hazards shared by most insulin pumps on the market. The aim of this article is to extend our previous work on the GIIP model by articulating safety requirements that address the identified GIIP hazards. These safety requirements can be validated by manufacturers, and may ultimately serve as a safety reference for insulin pump software. Together, these two publications can serve as a basis for discussing insulin pump safety in the diabetes community. Methods In our previous work, we established a generic insulin pump architecture that abstracts functions common to many insulin pumps currently on the market and near-future pump designs. We then carried out a preliminary hazard analysis based on this architecture that included consultations with many domain experts. Further consultation with domain experts resulted in the safety requirements used in the modeling work presented in this article. Results Generic safety requirements for the GIIP model are presented, as appropriate, in parameterized format to accommodate clinical practices or specific insulin pump criteria important to safe device performance. Conclusions We believe that there is considerable value in having the diabetes, academic, and manufacturing communities consider and discuss these generic safety requirements. We hope that the communities will extend and revise them, make them more representative and comprehensive, experiment with them, and use them as a means for assessing the safety of insulin pump software designs. One potential use of these requirements is to integrate them into model-based engineering (MBE) software development methods. We believe, based on our experiences, that implementing safety requirements using MBE methods holds promise in reducing design/implementation flaws in insulin pump development and evolutionary processes, therefore improving

  14. Analog experiment of transarterial catheter hyperthermic infusion in vitro

    International Nuclear Information System (INIS)

    Fan Shufeng Li Zheng; Gu Weizhong; Ru Fuming

    2006-01-01

    Objective: To investigate the factors related to the heating effect by transarterial catheter hyperthermic infusion with the evaluation of the feasibility in controlling the tumor temperature. Methods: Infusing 55-68 degree C liquid at the speed of 10-40 ml/min through 6F, 5F or 3F catheter with different length respectively under the similar clinical condition. The liquid temperature at the terminal exit of the catheter was measured with a digital thermometer. The factors related to the liquid temperature at the exit of the catheter were analyzed by multiple regression analysis. Results: The infusion temperature , rate and the catheter length were the main related factors to the liquid temperature at the exit of the catheter as the condition similar in clinical use. When 60-65 degree C liquid was infused at the rate of 20-40 ml/min through 5F catheter with length of 80 cm, the mean and 95% confident interval of the liquid temperature at the catheter exit were (47.55±0.44) degree C and 44.61-48.49 degree C respectively. Conclusions: The liquid temperature at the exit of infusion catheter can be regulated and controlled through adjusting the liquid perfusion temperature and speed. (authors)

  15. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid N

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describe the software programs for the Programmable Logic Controller and the Datable Access Module for Pumping Instrumentation and Control skid ''N''. The Appendices contains copies of the printouts of these software programs. This document describes the software programs for the Allen-Bradley SLC 500 programmable logic controller (PLC) and the Allen-Bradley DTAM PLUS operator interface module used on Pumping Instrumentation and Control (PIC) skid ''N''. The software programs for the SLC 500 and DTAM Plus are based on the core programs provided by Allen-Bradley. The PLC and DTAM software programs on skid ''D'' for SX-104 are the baseline programs. These baselines have been tailored for U-farm skids. The skid ''N'' program for U-109 is similar to the skid ''M'' program for U-102. An Acceptance Test Procedure (ATP) and an Operational Test Procedure (OTP) verify that the software programs meet the specific requirements for U-109 pumping. This document represents the final PLC and DTAM programs for PIC skid ''N'' at U-109. These programs were printed out after the performance of the OTP. The OTP acts as the final qualification test for the software programs. Functional requirements and details of the PLC ladder logic are described in this document. The final programs entered into the PLC and DTAM Plus are included as Appendices to this document

  16. High-vacuum plasma pump

    International Nuclear Information System (INIS)

    Dorodnov, A.M.; Minajchev, V.E.; Miroshkin, S.I.

    1980-01-01

    The action of an electric-arc high-vacuum pump intended for evacuating the volumes in which the operation processes are followed by a high gas evolution is considered. The operation of the pump is based on the principle of controlling the getter feed according to the gas load and effect of plasma sorbtion pumping. The pump performances are given. The starting pressure is about 5 Pa, the limiting residual pressure is about 5x10 -6 Pa, the pumping out rate of nitrogen in the pressure range 5x10 -5 -5x10 -3 Pa accounts for about 4000 l/s, the power consumption comes to 6 kW. Analyzing the results of the test operation of the pump, it has been concluded that its principal advantages are the high starting pressure, controlled getter feed rate and possibility of pumping out the gases which are usually pumped out with difficulty. The operation reliability of the pump is defined mainly by reliable operation of the ignition system of the vacuum arc [ru

  17. Intrathecal Pump Exposure to Electromagnetic Interference: A Report of Device Interrogation following Multiple ECT Sessions.

    Science.gov (United States)

    Bicket, Mark C; Hanna, George M

    2016-02-01

    Intrathecal drug delivery systems represent an increasingly common treatment modality for patients with a variety of conditions, including chronic pain and spasticity. Pumps rely on electronic programming to properly control and administer highly concentrated medications. Electromagnetic interference (EMI) is a known exposure that may cause a potential patient safety issue stemming from direct patient injury, pump damage, or changes to pump operation or flow rate. The objective of our case report was to describe an approach to evaluating a patient with a pump prior to and following exposure to EMI from electroconvulsive therapy (ECT), as well as to document findings from device interrogations associated with this event. Case report. Academic university-based pain management center. We present the case of a patient with an intrathecal pump who underwent multiple exposures to EMI in the form of 42 ECT sessions. Interrogation of the intrathecal drug delivery system revealed no safety issues following ECT sessions. At no time were error messages, unintentional changes in event logs, unintentional changes in pump settings, or evidence of pump stall or over-infusion noted. Communication with multiple entities (patient, family, consulting physicians, and device manufacturer) and maintaining vigilance through device interrogation both before and after EMI exposure are appropriate safeguards to mitigate the risk and detect potential adverse events of EMI with intrathecal drug delivery systems. Given the infrequent reports of device exposure to ECT, best practices may be derived from experience with EMI exposure from magnetic resonance imaging (MRI). Although routine EMI exposure to intrathecal drug delivery systems should be avoided, we describe one patient with repeated exposure to ECT without apparent complication.

  18. Improving the Efficiency of the Heat Pump Control System of Carbon Di-oxide Heat Pump with Several Evaporators and Gas Coolers

    OpenAIRE

    Sit, M.L.; Juravliov, A.A.; Sit, B.M.; Timchenko, D.

    2016-01-01

    The problem of coordination of the values of the refrigerant flow through the evaporators and gas coolers of the heat pump for the simultaneous production of heat and cold is studied. The compensation of the variations of the total flow through the evaporators is implemented using the variation of the capacity of the compressor and a corresponding change in flow through the auxiliary gas cooler of the heat pump. Control system of this gas cooler is constructed using the invariance principle o...

  19. Earliest Deadline Control of a Group of Heat Pumps with a Single Energy Source

    NARCIS (Netherlands)

    Fink, J.; van Leeuwen, Richard Pieter

    2016-01-01

    In this paper, we develop and investigate the optimal control of a group of 104 heat pumps and a central Combined Heat and Power unit (CHP). The heat pumps supply space heating and domestic hot water to households. Each house has a buffer for domestic hot water and a floor heating system for space

  20. Effectiveness of terbutaline pump for the prevention of preterm birth. A systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Laura M Gaudet

    Full Text Available Subcutaneous terbutaline (SQ terbutaline infusion by pump is used in pregnant women as a prolonged (beyond 48-72 h maintenance tocolytic following acute treatment of preterm contractions. The effectiveness and safety of this maintenance tocolysis have not been clearly established. We aimed to systematically evaluate the effectiveness and safety of subcutaneous (SQ terbutaline infusion by pump for maintenance tocolysis.MEDLINE, EMBASE, CINAHL, the Cochrane Library, the Centre for Reviews and Dissemination databases, post-marketing surveillance data and grey literature were searched up to April 2011 for relevant experimental and observational studies. Two randomized trials, one nonrandomized trial, and 11 observational studies met inclusion criteria. Non-comparative studies were considered only for pump-related harms. We excluded case-reports but sought FDA summaries of post-marketing surveillance data. Non-English records without an English abstract were excluded. Evidence of low strength from observational studies with risk of bias favored SQ terbutaline pump for the outcomes of delivery at <32 and <37 weeks, mean days of pregnancy prolongation, and neonatal death. Observational studies of medium to high risk of bias also demonstrated benefit for other surrogate outcomes, such as birthweight and neonatal intensive care unit (NICU admission. Several cases of maternal deaths and maternal cardiovascular events have been reported in patients receiving terbutaline tocolysis.Although evidence suggests that pump therapy may be beneficial as maintenance tocolysis, our confidence in its validity and reproducibility is low, suggesting that its use should be limited to the research setting. Concerns regarding safety of therapy persist.

  1. Acceptance Test Procedure for New Pumping and Instrumentation Control Skid L

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping and Instrumentation Control (PIC) skid designed as ''L''. The ATP will be performed after the construction of the PIC skid in the shop

  2. Acceptance Test Procedure for New Pumping and Instrumentation Control Skid N

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping and Instrumentation Control (PIC) skid designed as ''N''. The ATP will be performed after the construction of the PIC skid in the shop

  3. Development of electric drive for centrifugal mine pumps in Solikamsk Potassium Mine Group Based on Industrial OMRON Controller

    Science.gov (United States)

    Kostarev, S. N.; Sereda, T. G.; Tatarnikova, N. A.; Kochetova, O. V.

    2018-03-01

    The electric drive for automation pumping out of filtration waters in the Second Solikamsk Potasssium Mine Group is developed. The emergency situation of flooding of the Mine has been considered in the course of development of the Upper Kama deposits of potash-magnesium salts. The functional scheme of automation of a drive of the pump is developed. The scheme is stipulated with manual and automatic control. To decrease the risk of flooding of mine, it is recommended to establish gauges of both bottom and top level control of a brine and other equipment in the collector of a brine: the gauge of measurementof a level, the gauge of the signal system of a level, the gauge of the pump control, the gauge of the signal system of a level with remote data transmission. For regulation of the charge of sewage, the P-regulator with the executive mechanism is stipulated. The ladder diagram of a pump control is developed to improve the work of centrifugal pumps and to prevent the cases of mines flooding.

  4. COMPARISON OF THE EFFECTS OF INTERCOSTAL NERVE BLOCK WITH ROPIVACAINE AND INTRAVENOUS PARACETAMOL INFUSION TO INTRAVENOUS PARACETAMOL INFUSION ALONE FOR PAIN CONTROL AFTER OPEN CHOLECYSTECTOMY

    Directory of Open Access Journals (Sweden)

    Somnath Dey

    2017-11-01

    Full Text Available BACKGROUND Postoperative pain after open cholecystectomy is associated with respiratory dysfunction, increased stress response and prolonged hospital stay. We compare intravenous paracetamol (7.5 mg/kg plus intercostal nerve block with local anaesthetic ropivacaine 0.5% to intravenous paracetamol (15 mg/kg on pain control after open cholecystectomy. MATERIALS AND METHODS 140 patients, who underwent for open cholecystectomy, were randomly divided into two groups of 70. The patients were randomly allocated to any of the following two groups depending upon the drug used for analgesia (Group P or Group I Intravenous paracetamol 15 mg/kg was given to patients of group P and paracetamol 7.5 mg/kg with Intercostal nerve block in right side 6-10 intercostal nerves with 2 ml local anaesthetic ropivacaine 0.5% in each space was given to patients of group I just after intubation before incision. When the patients were transferred to postoperative recovery room, intensity of pain was recorded by response from the patients using 100 mm linear visual analogue scale ranging from 0 to 100. The pain scoring was done in the immediate postoperative period (when the patient was able to communicate in the post anaesthesia care unit, at 30 minutes, 1 hr. then hourly up to 24 hrs. till patient complained of pain with VAS score 40 or more. RESULTS The severity of pain in VAS score was lower in immediate postoperative period, at 30 minutes, 1 hour and 2 hours postoperatively in group I than the group P and those were statistically significant (p<0.001. Duration of analgesia also significantly lower in group I. Mean duration of analgesia in group P is 161.9 ± 42.6 min and in group I is 241.3 ± 44.2 min (p<0.001. CONCLUSION Adding Intercostal nerve block to intravenous infusion of Paracetamol infusion (7.5 mg/kg is better than sole intravenous infusion of Paracetamol (15 mg/kg in controlling pain severity even after reducing dose of paracetamol after open

  5. Feasibility of bispectral index-guided propofol infusion for flexible bronchoscopy sedation: a randomized controlled trial.

    Directory of Open Access Journals (Sweden)

    Yu-Lun Lo

    Full Text Available There are safety issues associated with propofol use for flexible bronchoscopy (FB. The bispectral index (BIS correlates well with the level of consciousness. The aim of this study was to show that BIS-guided propofol infusion is safe and may provide better sedation, benefiting the patients and bronchoscopists.After administering alfentanil bolus, 500 patients were randomized to either propofol infusion titrated to a BIS level of 65-75 (study group or incremental midazolam bolus based on clinical judgment to achieve moderate sedation. The primary endpoint was safety, while the secondary endpoints were recovery time, patient tolerance, and cooperation.The proportion of patients with hypoxemia or hypotensive events were not different in the 2 groups (study vs. control groups: 39.9% vs. 35.7%, p = 0.340; 7.4% vs. 4.4%, p = 0.159, respectively. The mean lowest blood pressure was lower in the study group. Logistic regression revealed male gender, higher American Society of Anesthesiologists physical status, and electrocautery were associated with hypoxemia, whereas lower propofol dose for induction was associated with hypotension in the study group. The study group had better global tolerance (p<0.001, less procedural interference by movement or cough (13.6% vs. 36.1%, p<0.001; 30.0% vs. 44.2%, p = 0.001, respectively, and shorter time to orientation and ambulation (11.7±10.2 min vs. 29.7±26.8 min, p<0.001; 30.0±18.2 min vs. 55.7±40.6 min, p<0.001, respectively compared to the control group.BIS-guided propofol infusion combined with alfentanil for FB sedation provides excellent patient tolerance, with fast recovery and less procedure interference.ClinicalTrials. gov NCT00789815.

  6. Chemoradiotherapy using retrograde superselective intra-arterial infusion for advanced oral cancer

    International Nuclear Information System (INIS)

    Mitsudo, Kenji; Iwai, Toshinori; Mitsunaga, Sachiyo

    2011-01-01

    Concurrent chemoradiotherapy using retrograde superselective intra-arterial infusion demonstrates good local control and overall survival rates due to the advantage of simultaneous infusion of anticancer agent with the synergistic effects of chemotherapy and radiotherapy. This study evaluated the therapeutic results, overall survival and local control rates in patients with advanced oral cancer treated with definitive concurrent chemoradiotherapy using retrograde superselective intra-arterial infusion. A total of 688 patients with carcinoma of the head and neck were referred to our institution between January 2001 and December 2006. Among them, 175 patients with carcinoma of the oral cavity underwent definitive concurrent chemoradiotherapy using retrograde superselective intra-arterial infusion. Treatment consisted of superselective intra-arterial infusions (docetaxel, total 60 mg/m 2 , cisplatin, total 125-150 mg/m 2 ) and daily concurrent radiotherapy (total 50-60 Gy) for 5-6 weeks. Four weeks after the completion of all treatments, patients underwent biopsy of the primary lesion and radiological examinations. Complete response (CR) of the primary site was achieved in 160 (91.4%) of the 175 patients. Residual disease at the primary site was seen in 15 patients (8.6%), and 14 patients (8.0%) showed local recurrence during follow-up. Five-year survival and local control rates were 71.6% and 82.2%, respectively. (author)

  7. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''P''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''P''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  8. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid W

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''W''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  9. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid V

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control. (PIC) skid designed as ''V''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  10. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''V''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designated as ''V''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  11. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''Q''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''Q''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  12. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''T''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designated as ''T''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  13. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid T

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing Of the new Pumping Instrumentation and Control (PIC) skid designed as ''T''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  14. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid R

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''R''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  15. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''U''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''U''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  16. Three cases of radiation esophagitis controlled with proton pump inhibitor

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Ryuji; Saito, Ryuichi; Miyazaki, Toshiyuki [Kumamoto Red Cross Hospital (Japan)

    2002-04-01

    Radiation esophagitis sometimes interrupts the radiation therapy due to swallowing pain and dysplasia. We experienced three cases of radiation-induced esophagitis controlled with proton pump inhibitor (PPI). These cases suggested etiologic relationship radiation esophagitis and gastroesophageal reflux disease (GERD). We should consider PPI as treatment option for radiation esophagitis. (author)

  17. Performance investigation on a multi-unit heat pump for simultaneous temperature and humidity control

    International Nuclear Information System (INIS)

    Fan, Hongming; Shao, Shuangquan; Tian, Changqing

    2014-01-01

    Highlights: • A multi-unit heat pump is proposed for simultaneous temperature and humidity control. • Condensation heat is non, partly or fully recovered for temperature regulation. • Highly integrated heat pump for residential cooling, dehumidification and heating. • High energy saving potential for all-year-round operation in wet and warm regions. - Abstract: A multi-unit heat pump is presented for simultaneous humidity and temperature control to improve the energy efficiency and the thermal comfort. Two parallel connected condensers are employed in the system, locating at the back of the indoor evaporator and the outdoor unit, respectively. The heat pump can operate in four modes, including heating, cooling and dehumidification without and/or with partial or total condensing heat recovery. The experimental investigation shows that the temperature control capacity is from 3.5 kW for cooling to 3.8 kW for heating with the cooling and heating efficiency higher than 3.5 kW kW −1 , and the dehumidification rate is about 2.0 kg h −1 with the efficiency about 2.0 kg h −1 kW −1 . The supply air temperature and humidity can be simultaneously regulated with high accuracy and high efficiency by adjusting the indoor and/or outdoor air volumes. It provides an integrated and effective solution for simultaneous indoor air temperature and humidity control for all-year-round operation in residential buildings

  18. Hippocampal Infusion of Zeta Inhibitory Peptide Impairs Recent, but Not Remote, Recognition Memory in Rats

    Directory of Open Access Journals (Sweden)

    Jena B. Hales

    2015-01-01

    Full Text Available Spatial memory in rodents can be erased following the infusion of zeta inhibitory peptide (ZIP into the dorsal hippocampus via indwelling guide cannulas. It is believed that ZIP impairs spatial memory by reversing established late-phase long-term potentiation (LTP. However, it is unclear whether other forms of hippocampus-dependent memory, such as recognition memory, are also supported by hippocampal LTP. In the current study, we tested recognition memory in rats following hippocampal ZIP infusion. In order to combat the limited targeting of infusions via cannula, we implemented a stereotaxic approach for infusing ZIP throughout the dorsal, intermediate, and ventral hippocampus. Rats infused with ZIP 3–7 days after training on the novel object recognition task exhibited impaired object recognition memory compared to control rats (those infused with aCSF. In contrast, rats infused with ZIP 1 month after training performed similar to control rats. The ability to form new memories after ZIP infusions remained intact. We suggest that enhanced recognition memory for recent events is supported by hippocampal LTP, which can be reversed by hippocampal ZIP infusion.

  19. Central model predictive control of a group of domestic heat pumps, case study for a small district

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; Helfert, Markus; Krempels, Karl-Heinz; Donnellan, Brian; Klein, Cornel

    2015-01-01

    In this paper we investigate optimal control of a group of heat pumps. Each heat pump provides space heating and domestic hot water to a single household. Besides a heat pump, each house has a buffer for domestic hot water and a floor heating system for space heating. The paper describes models and

  20. Short locking time and low jitter phase-locked loop based on slope charge pump control

    International Nuclear Information System (INIS)

    Guo Zhongjie; Liu Youbao; Wu Longsheng; Wang Xihu; Tang Wei

    2010-01-01

    A novel structure of a phase-locked loop (PLL) characterized by a short locking time and low jitter is presented, which is realized by generating a linear slope charge pump current dependent on monitoring the output of the phase frequency detector (PFD) to implement adaptive bandwidth control. This improved PLL is created by utilizing a fast start-up circuit and a slope current control on a conventional charge pump PLL. First, the fast start-up circuit is enabled to achieve fast pre-charging to the loop filter. Then, when the output pulse of the PFD is larger than a minimum value, the charge pump current is increased linearly by the slope current control to ensure a shorter locking time and a lower jitter. Additionally, temperature variation is attenuated with the temperature compensation in the charge pump current design. The proposed PLL has been fabricated in a kind of DSP chip based on a 0.35 μm CMOS process. Comparing the characteristics with the classical PLL, the proposed PLL shows that it can reduce the locking time by 60% with a low peak-to-peak jitter of 0.3% at a wide operation temperature range. (semiconductor integrated circuits)

  1. Air Pump-Assisted Graft Centration, Graft Edge Unfolding, and Graft Uncreasing in Young Donor Graft Pre-Descemet Endothelial Keratoplasty.

    Science.gov (United States)

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Agarwal, Athiya; A I, Saijimol

    2017-08-01

    To assess an air pump-assisted technique for graft centration, graft edge unfolding, and graft uncreasing while performing pre-Descemet endothelial keratoplasty (PDEK) using young donor grafts. Continuous pressurized air infusion was used for graft centration, graft edge unfolding, and graft unwrinkling. Ten eyes of 10 patients underwent PDEK with donors aged below 40 years. In all eyes, the donor scrolled into tight scrolls. In all cases, the air pump-assisted technique was effective in positioning and centering the graft accurately and in straightening infolded graft edges and smoothing out graft creases and wrinkles. Endothelial cell loss was 38.6%. Postoperative best-corrected visual acuity at 6 months was 0.66 ± 0.25 in decimal equivalent. Continuous pressurized air infusion acted as a third hand providing a continuous pressure head that supported the graft and prevented graft dislocation as well as anterior chamber collapse during intraocular maneuvering. Adequate maneuvering space was available in all cases, and bleeding, if any, was tamponaded successfully in all cases. Although very young donor grafts may be used for PDEK, they are difficult to center and unroll completely before floating against host stroma. An air pump-assisted technique using continuous pressurized air infusion allows successful final graft positioning even with very young donor corneas. It thus makes surgery easier as several key steps are made easier to handle. It additionally helps in tamponading hemorrhage during peripheral iridectomy, increasing surgical space, preventing fluctuations in the anterior chamber depth, and promoting graft adherence.

  2. Pump audit identifies the energy consumers; Pump Audit identifiziert gezielt die Energieverschwender

    Energy Technology Data Exchange (ETDEWEB)

    Siekemann, Ralf [Grundfos GmbH, Erkrath (Germany)

    2011-03-14

    Engineering and services, which enhance and secure the energy efficiency of pump systems, are demanded. Speed-regulated pumps, included high efficient motors and a service philosophy, be designed on value conservation and cost control, are as well as professional ''pump-audits''. (orig./GL)

  3. Benefits and risks of using smart pumps to reduce medication error rates: a systematic review.

    Science.gov (United States)

    Ohashi, Kumiko; Dalleur, Olivia; Dykes, Patricia C; Bates, David W

    2014-12-01

    Smart infusion pumps have been introduced to prevent medication errors and have been widely adopted nationally in the USA, though they are not always used in Europe or other regions. Despite widespread usage of smart pumps, intravenous medication errors have not been fully eliminated. Through a systematic review of recent studies and reports regarding smart pump implementation and use, we aimed to identify the impact of smart pumps on error reduction and on the complex process of medication administration, and strategies to maximize the benefits of smart pumps. The medical literature related to the effects of smart pumps for improving patient safety was searched in PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials (CENTRAL) (2000-2014) and relevant papers were selected by two researchers. After the literature search, 231 papers were identified and the full texts of 138 articles were assessed for eligibility. Of these, 22 were included after removal of papers that did not meet the inclusion criteria. We assessed both the benefits and negative effects of smart pumps from these studies. One of the benefits of using smart pumps was intercepting errors such as the wrong rate, wrong dose, and pump setting errors. Other benefits include reduction of adverse drug event rates, practice improvements, and cost effectiveness. Meanwhile, the current issues or negative effects related to using smart pumps were lower compliance rates of using smart pumps, the overriding of soft alerts, non-intercepted errors, or the possibility of using the wrong drug library. The literature suggests that smart pumps reduce but do not eliminate programming errors. Although the hard limits of a drug library play a main role in intercepting medication errors, soft limits were still not as effective as hard limits because of high override rates. Compliance in using smart pumps is key towards effectively preventing errors. Opportunities for improvement include upgrading drug

  4. Wireless implantable chip with integrated nitinol-based pump for radio-controlled local drug delivery.

    Science.gov (United States)

    Fong, Jeffrey; Xiao, Zhiming; Takahata, Kenichi

    2015-02-21

    We demonstrate an active, implantable drug delivery device embedded with a microfluidic pump that is driven by a radio-controlled actuator for temporal drug delivery. The polyimide-packaged 10 × 10 × 2 mm(3) chip contains a micromachined pump chamber and check valves of Parylene C to force the release of the drug from a 76 μL reservoir by wirelessly activating the actuator using external radio-frequency (RF) electromagnetic fields. The rectangular-shaped spiral-coil actuator based on nitinol, a biocompatible shape-memory alloy, is developed to perform cantilever-like actuation for pumping operation. The nitinol-coil actuator itself forms a passive 185 MHz resonant circuit that serves as a self-heat source activated via RF power transfer to enable frequency-selective actuation and pumping. Experimental wireless operation of fabricated prototypes shows successful release of test agents from the devices placed in liquid and excited by radiating tuned RF fields with an output power of 1.1 W. These tests reveal a single release volume of 219 nL, suggesting a device's capacity of ~350 individual ejections of drug from its reservoir. The thermal behavior of the activated device is also reported in detail. This proof-of-concept prototype validates the effectiveness of wireless RF pumping for fully controlled, long-lasting drug delivery, a key step towards enabling patient-tailored, targeted local drug delivery through highly miniaturized implants.

  5. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''P''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping Instrumentation and Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis

  6. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid Q

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping Instrumentation and Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis

  7. Auto-control of pumping operations in sewerage systems by rule-based fuzzy neural networks

    Directory of Open Access Journals (Sweden)

    Y.-M. Chiang

    2011-01-01

    Full Text Available Pumping stations play an important role in flood mitigation in metropolitan areas. The existing sewerage systems, however, are facing a great challenge of fast rising peak flow resulting from urbanization and climate change. It is imperative to construct an efficient and accurate operating prediction model for pumping stations to simulate the drainage mechanism for discharging the rainwater in advance. In this study, we propose two rule-based fuzzy neural networks, adaptive neuro-fuzzy inference system (ANFIS and counterpropagation fuzzy neural network for on-line predicting of the number of open and closed pumps of a pivotal pumping station in Taipei city up to a lead time of 20 min. The performance of ANFIS outperforms that of CFNN in terms of model efficiency, accuracy, and correctness. Furthermore, the results not only show the predictive water levels do contribute to the successfully operating pumping stations but also demonstrate the applicability and reliability of ANFIS in automatically controlling the urban sewerage systems.

  8. Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.

    Science.gov (United States)

    Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson

    2018-05-10

    The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.

  9. Power flow control based solely on slow feedback loop for heart pump applications.

    Science.gov (United States)

    Wang, Bob; Hu, Aiguo Patrick; Budgett, David

    2012-06-01

    This paper proposes a new control method for regulating power flow via transcutaneous energy transfer (TET) for implantable heart pumps. Previous work on power flow controller requires a fast feedback loop that needs additional switching devices and resonant capacitors to be added to the primary converter. The proposed power flow controller eliminates these additional components, and it relies solely on a slow feedback loop to directly drive the primary converter to meet the heart pump power demand and ensure zero voltage switching. A controlled change in switching frequency varies the resonant tank shorting period of a current-fed push-pull resonant converter, thus changing the magnitude of the primary resonant voltage, as well as the tuning between primary and secondary resonant tanks. The proposed controller has been implemented successfully using an analogue circuit and has reached an end-to-end power efficiency of 79.6% at 10 W with a switching frequency regulation range of 149.3 kHz to 182.2 kHz.

  10. Dimensional and Structural Control of Silica Aerogel Membranes for Miniaturized Motionless Gas Pumps.

    Science.gov (United States)

    Zhao, Shanyu; Jiang, Bo; Maeder, Thomas; Muralt, Paul; Kim, Nayoung; Matam, Santhosh Kumar; Jeong, Eunho; Han, Yen-Lin; Koebel, Matthias M

    2015-08-26

    With growing public interest in portable electronics such as micro fuel cells, micro gas total analysis systems, and portable medical devices, the need for miniaturized air pumps with minimal electrical power consumption is on the rise. Thus, the development and downsizing of next-generation thermal transpiration gas pumps has been investigated intensively during the last decades. Such a system relies on a mesoporous membrane that generates a thermomolecular pressure gradient under the action of an applied temperature bias. However, the development of highly miniaturized active membrane materials with tailored porosity and optimized pumping performance remains a major challenge. Here we report a systematic study on the manufacturing of aerogel membranes using an optimized, minimal-shrinkage sol-gel process, leading to low thermal conductivity and high air conductance. This combination of properties results in superior performance for miniaturized thermomolecular air pump applications. The engineering of such aerogel membranes, which implies pore structure control and chemical surface modification, requires both chemical processing know-how and a detailed understanding of the influence of the material properties on the spatial flow rate density. Optimal pumping performance was found for devices with integrated membranes with a density of 0.062 g cm(-3) and an average pore size of 142.0 nm. Benchmarking of such low-density hydrophobic active aerogel membranes gave an air flow rate density of 3.85 sccm·cm(-2) at an operating temperature of 400 °C. Such a silica aerogel membrane based system has shown more than 50% higher pumping performance when compared to conventional transpiration pump membrane materials as well as the ability to withstand higher operating temperatures (up to 440 °C). This study highlights new perspectives for the development of miniaturized thermal transpiration air pumps while offering insights into the fundamentals of molecular pumping in

  11. Insulin Pump and CGM Usage in the United States and Germany

    Science.gov (United States)

    Walsh, John; Roberts, Ruth; Weber, Dietmar; Faber-Heinemann, Gabriele; Heinemann, Lutz

    2015-01-01

    Background: This survey collected and evaluated user responses about routine tasks and preferences regarding insulin pumps and infusion sets (IIS) with comparison of intercountry differences between the United States (US) and Germany (GER), chosen for their large insulin pump populations. Methods: A total of 985 subjects (534 US, 451 GER; 60% female) with type 1 diabetes on pump therapy anonymously answered 20 pump-related questions. US subjects also answered 11 questions about continuous glucose monitoring (CGM) usage. Results: Length of use of insulin cartridges is shorter in US than in GER, mean (SD) 4.3 (5.0) versus 5.3 (3.2) days (P 3 days vs 7.7% for <3 days; P < .01), and with use of an auto-insertion device (vs manual IIS insertion) in the US (7.2% vs 6.9%), but not in GER (7.7% vs 7.9%). Only 47% of pump wearers stated that they were “very satisfied” with their pump (49% US vs 45% GER, ns). However, 98% would recommend the pump to others (95% vs 93%, ns). Analysis of CGM questions showed that 297 (60%) of 496 US responders currently wore one. Of these, 84% said they would recommend CGM to others. CGM wearers who stated they were “very satisfied” with their CGM had lower HbA1c than those who said they were “partly satisfied” (6.9% vs 7.2%). Conclusions: This survey shows interesting differences in real-world use of insulin pumps in 2 large markets, and suggests areas where insulin pumps and CGMs might be improved. PMID:26071425

  12. The Control of Welding Deformation of the Three-Section Arm of Placing Boom of HB48B Pump Truck

    Science.gov (United States)

    Wang, Zhi-ling

    2018-02-01

    The concrete pump truck is the construction equipment of conveying concrete with self contained base plate and distributing boom. It integrates the pump transport mechanism of the concrete pump, and the hydraulic roll-folding type distributing boom used to distribute materials, and the supporting mechanism into the automobile chassis, and it is the concrete conveying equipment with high efficient and the functions of driving, pumping, and distributing materials. The placing boom of the concrete pump truck is the main force member in the pump parts with bearing great pressure, and its stress condition is complex. Taking the HB48B placing boom as an example, this paper analyzes and studies the deformation produced by placing boom of pump truck, and then obtains some main factors affecting the welding deformation. Through the riveter “joint” size, we controlled the process parameters, post-welding processing, and other aspects. These measures had some practical significance to prevent, control, and reduce the deformation of welding.

  13. A Robust MPP Tracker Based on Sliding Mode Control for a Photovoltaic Based Pumping System

    Institute of Scientific and Technical Information of China (English)

    Farhat Maissa; Oscar Barambones; Sbita Lassad; Aymen Fleh

    2017-01-01

    In this paper,a mathematical model of the photovoltaic (PV) pumping system's main components is firstly established.Then,the design of maximum power point tracking (MPPT) stage that ensures battery charging is described.This work is motivated by the need of photovoltaic generator (PVG) that efficiently extracts maximum power.The PVG is a special source of energy which has nonlinear current-voltage characteristics depending on variations in temperature and solar irradiance.In order to achieve the MPPT operating goals,a special interest is focused on the variable structure sliding mode (SM) control strategy and the classic perturb and observe (P&O) algorithm.The permanent magnet synchronous motor (PMSM) is selected as a pump driver.The field oriented control is performed as the motor drive strategy.Simulation results show a high level of efficiency,obtained with the proposed PV based pumping system.The performance comparison between SM controller and P&O controller has been carried out to demonstrate the effectiveness of the former in drawing more energy and a fast response against irradiation disturbances.

  14. Ubiquitous Sensor Networks: Efisiensi Sistem Kontrol Cairan Infus Pasien Rawat Inap

    Directory of Open Access Journals (Sweden)

    BUDI RAHMADYA

    2017-07-01

    Full Text Available ABSTRAKPenelitian ini membahas tentang sistem kontrol cairan infus pada pasien dengan memanfaatkan teknologi sensor networks dan mikrokontroler arduino uno.  Sensor yang digunakan adalah sensor Ultrasonik HC-SR04 yang difungsikan untuk mendeteksi sisa cairan infus. Data yang terbaca oleh sensor dikirimkan menggunakan jaringan nirkabel/wireless dari Transmitter (Tx di ruang pasien ke Receiver (Rx di ruang perawat dengan menggunakan modul wireless Xbee S2. Efisiensi dari sistem kontrol yang dibuat yaitu ketika sensor mendeteksi cairan infus mendekati batas habis cairan yang telah ditentukan maka motor yang berada pada selang infus akan berfungsi untuk menutup aliran cairan infus pada selang. Dari simulasi yang dilakukan, didapatkan hasil presentasi error ketinggian cairan infus sebesar 1.96% dan presentasi error volume cairan sebesar 2.16%. Performa dari modul wireless Xbee S2 juga di ujicoba dengan mengirimkan data dari Xbee end device ke Xbee coordinator dalam penelitian ini. Kata kunci: Infus, Sensor Networks, Sensor Ultrasonik HC-SR04, Xbee S2 dan Mikrokontroler Arduino Uno.ABSTRACTThis research discusses about intravenous fluids Control System on Patients, utilizing sensor network technology and Arduino Uno microcontroller. We used  HC-SR04 Ultrasonic sensors to detect the review time intravenous fluids. The sensors data is readable by transmitted using wireless network/wireless from Transmitter (Tx in Patients Into Space Receiver (Rx at nurse room with using XBee wireless device S2. The efficiency of the control system were made, namely when the sensor detects the approaching limits of intravenous fluids discharged liquid that has been determined then the motor that was on the infus line will serve to close the infusion fluid flow in the line. In our simulations we found, the findings obtained Presentation intravenous fluids altitude error is 1.96% and presentations volume Liquid error is 2.16%. The performance of network devices XBee S2

  15. System control fuzzy neural sewage pumping stations using genetic algorithms

    Directory of Open Access Journals (Sweden)

    Владлен Николаевич Кузнецов

    2015-06-01

    Full Text Available It is considered the system of management of sewage pumping station with regulators based on a neuron network with fuzzy logic. Linguistic rules for the controller based on fuzzy logic, maintaining the level of effluent in the receiving tank within the prescribed limits are developed. The use of genetic algorithms for neuron network training is shown.

  16. Depressed left ventricular performance. Response to volume infusion in patients with sepsis and septic shock

    International Nuclear Information System (INIS)

    Ognibene, F.P.; Parker, M.M.; Natanson, C.; Shelhamer, J.H.; Parrillo, J.E.

    1988-01-01

    Volume infusion, to increase preload and to enhance ventricular performance, is accepted as initial management of septic shock. Recent evidence has demonstrated depressed myocardial function in human septic shock. We analyzed left ventricular performance during volume infusion using serial data from simultaneously obtained pulmonary artery catheter hemodynamic measurements and radionuclide cineangiography. Critically ill control subjects (n = 14), patients with sepsis but without shock (n = 21), and patients with septic shock (n = 21) had prevolume infusion hemodynamic measurements determined and received statistically similar volumes of fluid resulting in similar increases in pulmonary capillary wedge pressure. There was a strong trend (p = 0.004) toward less of a change in left ventricular stroke work index (LVSWI) after volume infusion in patients with sepsis and septic shock compared with control subjects. The LVSWI response after volume infusion was significantly less in patients with septic shock when compared with critically ill control subjects (p less than 0.05). These data demonstrate significantly altered ventricular performance, as measured by LVSWI, in response to volume infusion in patients with septic shock

  17. The Sodium-Potassium Pump Controls the Intrinsic Firing of the Cerebellar Purkinje Neuron

    Science.gov (United States)

    Forrest, Michael D.; Wall, Mark J.; Press, Daniel A.; Feng, Jianfeng

    2012-01-01

    In vitro, cerebellar Purkinje cells can intrinsically fire action potentials in a repeating trimodal or bimodal pattern. The trimodal pattern consists of tonic spiking, bursting, and quiescence. The bimodal pattern consists of tonic spiking and quiescence. It is unclear how these firing patterns are generated and what determines which firing pattern is selected. We have constructed a realistic biophysical Purkinje cell model that can replicate these patterns. In this model, Na+/K+ pump activity sets the Purkinje cell's operating mode. From rat cerebellar slices we present Purkinje whole cell recordings in the presence of ouabain, which irreversibly blocks the Na+/K+ pump. The model can replicate these recordings. We propose that Na+/K+ pump activity controls the intrinsic firing mode of cerbellar Purkinje cells. PMID:23284664

  18. Effects of erythrocyte infusion on VO2max at high altitude

    DEFF Research Database (Denmark)

    Young, Jette Feveile; Sawka, M N; Muza, S R

    1996-01-01

    This study investigated whether autologous erythrocyte infusion would ameliorate the decrement in maximal O2 uptake (VO2max) experienced by lowlanders when they ascend to high altitude. VO2max was measured in 16 men (treadmill running) at sea level (SL) and on the 1st (HA1) and 9th (HA9) days...... of high-altitude (4,300 m) residence. After VO2max was measured at SL, subjects were divided into two matched groups (n = 8). Twenty-four hours before ascent to high altitude, the experimental group received a 700-ml infusion of autologous erythrocytes and saline (42% hematocrit), whereas the control...... group received only saline. The VO2max of erythrocyte-infused [54 +/- 1 (SE) ml.kg-1.min-1] and control subjects (52 +/- 2 ml.kg-1.min-1) did not differ at SL before infusion. The decrement in VO2max on HA1 did not differ between groups, averaging 26% overall, despite higher (P

  19. Continuous subcutaneous insulin infusion in diabetes: patient populations, safety, efficacy, and pharmacoeconomics

    OpenAIRE

    Pozzilli, Paolo; Battelino, Tadej; Danne, Thomas; Hovorka, Roman; Jarosz?Chobot, Przemyslawa; Renard, Eric

    2015-01-01

    Summary The level of glycaemic control necessary to achieve optimal short?term and long?term outcomes in subjects with type 1 diabetes mellitus (T1DM) typically requires intensified insulin therapy using multiple daily injections or continuous subcutaneous insulin infusion. For continuous subcutaneous insulin infusion, the insulins of choice are the rapid?acting insulin analogues, insulin aspart, insulin lispro and insulin glulisine. The advantages of continuous subcutaneous insulin infusion ...

  20. A simplified heat pump model for use in solar plus heat pump system simulation studies

    DEFF Research Database (Denmark)

    Perers, Bengt; Andersen, Elsa; Nordman, Roger

    2012-01-01

    Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here...

  1. In-use Stability of Ceftaroline Fosamil in Elastomeric Home Infusion Systems and MINI-BAG Plus Containers.

    Science.gov (United States)

    Bhattacharya, Sisir; Parekh, Satish; Dedhiya, Mahendra

    2015-01-01

    The objective of this study was to determine in-use stability of ceftaroline fosamil infusion solution of concentrations up to 12 mg/mL in elastomeric home infusion system prefilled with 0.9% Sodium Chloride Injection USP or 5% Dextrose Injection USP and MINI-BAG Plus Container delivery devices prefilled with 0.9% sodium chloride injection. In-use ceftaroline fosamil infusion solution (12 mg/mL) was prepared for elastomeric home infusion systems (Homepump Eclipse, Baxter Intermate, and AccuRx Elastomeric Pump) pre-filled with either 0.9% sodium chloride injection or 5% dextrose; or Baxter MINI-BAG Plus Containers pre-filled with 0.9% Sodium Chloride Injection USP (4 mg/mL to 12 mg/mL ceftaroline fosamil in final solution). The systems were stored refrigerated for 24 hours followed by up to 6 hours of storage at room temperature. Samples were analyzed at various time points for assay and degradation product by a validated stability-indicating high-performance liquid chromatography method. In-use ceftaroline fosamil infusion solution, ranging from 4-mg/mL to a maximum of 12-mg/mL concentration, in elastomeric home infusion systems prefilled with 0.9% sodium chloride injection or 5% dextrose, and MINI-BAG Plus Containers prefilled with 0.9% sodium chloride injection were chemically stable for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours at room temperature and had acceptable compatibility with material used. Ceftaroline fosamil (4 mg/mL to 12 mg/mL) maintains its potency for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours of storage at room temperature upon reconstitution in infusion solution with 0.9% sodium chloride or 5% dextrose when used in elastomeric home infusion system and MINI-BAG Plus Containers delivery devices prefilled with 0.9% sodium chloride injection.

  2. Optimal control of hydroelectric facility incorporating pump storage

    International Nuclear Information System (INIS)

    Zhao, Guangzhi; Davison, Matt

    2009-01-01

    We consider a simple model of a pump-assisted hydroelectric facility operating in a market with time-varying but deterministic power prices and constant water inflows. The engineering details of the facility are described by a model containing several parameters. We present an algorithm for optimizing first the energy and then the profit produced by these plants. This algorithm allows us to describe the relationships between control trajectory and time, and between inflow and price. Remarkably, we see that under some reasonable choices of facility parameters and for power prices that are not extremely variable, the optimal profit operation of these facilities is not too different from their optimal energy operation, and the control is less affected by the price as the inflow rate increases. (author)

  3. Continuous-infusion adriamycin

    International Nuclear Information System (INIS)

    Benjamin, R.S.; Chawla, S.P.; Ewer, M.S.; Hortobagyi, G.N.

    1986-01-01

    This chapter discusses the diminished cardiotoxicity as well as diminished nausea and vomiting with continuous infusions of adriamycin to patients undergoing radiation therapy, particularly with infusions of 48 hours or longer, and best with 96-hour infusions, the longest duration that has been studied systematically. In breast cancer, data show that more adriamycin is better, but only for a selected subgroup of patients: those with complete remission. The diminished cardiotoxicity makes the use of adriamycin more attractive in the adjuvant situation, where increased safety will decrease the chances of long-term complications and make retreatment easy for cured patients who develop second malignancies

  4. Sympathetic responses during saline infusion into the veins of an occluded limb.

    Science.gov (United States)

    Cui, Jian; McQuillan, Patrick; Moradkhan, Raman; Pagana, Charles; Sinoway, Lawrence I

    2009-07-15

    Animal studies have shown that the increased intravenous pressure stimulates the group III and IV muscle afferent fibres, and in turn induce cardiovascular responses. However, this pathway of autonomic regulation has not been examined in humans. The aim of this study was to examine the hypothesis that infusion of saline into the venous circulation of an arterially occluded vascular bed evokes sympathetic activation in healthy individuals. Blood pressure, heart rate, and muscle sympathetic nerve activity (MSNA) responses were assessed in 19 young healthy subjects during local infusion of 40 ml saline into a forearm vein in the circulatory arrested condition. From baseline (11.8 +/- 1.2 bursts min(-1)), MSNA increased significantly during the saline infusion (22.5 +/- 2.6 bursts min(-1), P Blood pressure also increased significantly during the saline infusion. Three control trials were performed during separate visits. The results from the control trial show that the observed MSNA and blood pressure responses were not due to muscle ischaemia. The present data show that saline infusion into the venous circulation of an arterially occluded vascular bed induces sympathetic activation and an increase in blood pressure. We speculate that the infusion under such conditions stimulates the afferent endings near the vessels, and evokes the sympathetic activation.

  5. Establishment of a low recycling state with full density control by active pumping of the closed helical divertor at LHD

    Science.gov (United States)

    Motojima, G.; Masuzaki, S.; Tanaka, H.; Morisaki, T.; Sakamoto, R.; Murase, T.; Tsuchibushi, Y.; Kobayashi, M.; Schmitz, O.; Shoji, M.; Tokitani, M.; Yamada, H.; Takeiri, Y.; The LHD Experiment Group

    2018-01-01

    Superior control of particle recycling and hence full governance of plasma density has been established in the Large Helical Device (LHD) using largely enhanced active pumping of the closed helical divertor (CHD). In-vessel cryo-sorption pumping systems inside the CHD in five out of ten inner toroidal divertor sections have been developed and installed step by step in the LHD. The total effective pumping speed obtained was 67  ±  5 m3 s-1 in hydrogen, which is approximately seven times larger than previously obtained. As a result, a low recycling state was observed with CHD pumping for the first time in LHD featuring excellent density control even under intense pellet fueling conditions. A global particle confinement time (τ p* ) is used for comparison of operation with and without the CHD pumping. The τ p* was evaluated from the density decay after the fueling of hydrogen pellet injection or gas puffing in NBI plasmas. A reliably low base density before the fueling and short τ p* after the fueling were obtained during the CHD pumping, demonstrating for the first time full control of the particle balance with active pumping in the CHD.

  6. LPS infusion suppresses serum FGF21 levels in healthy adult volunteers

    DEFF Research Database (Denmark)

    Lauritzen, Esben Stistrup; Rittig, Nikolaj; Bach, Ermina

    2017-01-01

    circulating levels of FGF21 after lipopolysaccharide (LPS) infusion. DESIGN: Two randomized, single blinded, placebo-controlled crossover trials were used. SETTING: The studies were performed at a university hospital clinical research center. PATIENTS AND INTERVENTIONS: Study 1 (LPS bolus): Eight young......, healthy, lean males were investigated two times: 1) after isotonic saline injection, and 2) after LPS injection (bolus of 1 ng/kg). Each study day lasted 4 hours. Study 2 (continuous LPS infusion): Eight, healthy males were investigated two times: 1) during continuously isotonic saline infusion, and 2......) during continuously LPS infusion (0.06 ng/kg/h). Each study day lasted 4 hours. Circulating FGF21 levels were quantified every second hour by an immunoassay. RESULTS: A LPS bolus resulted in a late suppression (t = 240 minutes) of serum FGF21 (P=0.035). Continuous LPS infusion revealed no significant...

  7. Overnight glucose control in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Duun-Henriksen, Anne Katrine; Schmidt, Signe

    2018-01-01

    This paper presents an individualized model predictive control (MPC) algorithm for overnight blood glucose stabilization in people with type 1 diabetes (T1D). The MPC formulation uses an asymmetric objective function that penalizes low glucose levels more heavily. We compute the model parameters...... algorithm uses frequent glucose measurements from a continuous glucose monitor (CGM) and its decisions are implemented by a continuous subcutaneous insulin infusion (CSII) pump. We provide guidelines for tuning the control algorithm and computing the Kalman gain in the linear state space model in innovation...

  8. Thrombolytic treatment for acute ischemic cerebral stroke: intraarterial urokinase infusion vs. intravenous heparin and urokinase infusion

    International Nuclear Information System (INIS)

    Ko, Gi Young; Suh, Dae Chul; Lee, Jae Hong; Kim, Jun Hyoung; Choi, Choong Gon; Lee, Ho Kyu; Lee, Myoung Chong

    1996-01-01

    To evaluate the efficacy and limitation of intra-arterial urokinase (IAUK) infusion for treatment of acute cerebral stroke. Twenty-seven acute cerebral stroke patients treated with IAUK infusion within six hours of stroke onset were reviewed. All patients showed normal initial brain findings on CT. In 21 patients, urokinase(5-15 x 10 5 IU) was administered through a microcatheter placed into or proximal to occluded segment. Mechanical disruption of thrombus by guidewire was performed in 17 patients. Angiographic and clinical responses and complications after IAUK infusion, were evaluated and the results were compared with those of intravenous heparin(N=19) and urokinase infusion(N=19). Complete or partial angiographic recanalization of occluded segment was found in 18 patients (67%), and neurologic improvement was followed in 14 patients(52%). The degree of improvement on the stroke scale score after IAUK infusion was statistically more significant(p<0.05) than that shown after intravenous heparin and urokinase infusion. Complications after IAUK infusion were large(15%) and small amount intracerebral hemorrhage(15%), contrast leakage into brain parenchyma(11%), and gastrointestinal bleeding(4%). Between the IAVK and the intravenous urokinase infusion group, differences in extent and types of complications were statistically insignificant, but were significantly higher in those two groups than in the intravenous heparin infusion group. IAUK infusion may be effective for the treatment of acute cerebral stroke

  9. Effect of Intrafix® SafeSet infusion apparatus on phlebitis in a neurological intensive care unit: a case-control study.

    Science.gov (United States)

    Liu, F; Chen, D; Liao, Y; Diao, L; Liu, Y; Wu, M; Xue, X; You, C; Kang, Y

    2012-01-01

    To investigate the effect of the Intrafix(®) SafeSet infusion apparatus on the incidence of phlebitis in patients being intravenously infused in a neurological intensive care unit (ICU). Patients aged > 12 years, with no history of diabetes mellitus and no existing phlebitis, requiring a daily peripheral intravenous infusion of ≥ 8 h with the total period lasting ≥ 3 days, were enrolled. Infusions were performed using the Intrafix(®) SafeSet or normal infusion apparatus. Incidence of phlebitis (scored according to the Infusion Nursing Standards of Practice of the American Infusion Nurses Society) was analysed. Patients (n = 1545) were allocated to Intrafix(®) SafeSet (n = 709) or normal infusion (n = 836) groups, matched for age, gender and preliminary diagnosis. Incidence of phlebitis was significantly higher using normal infusion apparatus compared with the Intrafix(®) SafeSet (23.4% versus 17.9%, respectively). Intrafix(®) SafeSet infusion apparatus significantly reduced the incidence of phlebitis in patients in the neurological ICU, compared with normal infusion apparatus, and may be suitable for use in routine clinical practice.

  10. Subcutaneous insulin infusion: change in basal infusion rate has no immediate effect on insulin absorption rate

    International Nuclear Information System (INIS)

    Hildebrandt, P.; Birch, K.; Jensen, B.M.; Kuehl, C.

    1986-01-01

    Eight insulin-dependent diabetic patients were simultaneously given subcutaneous infusions (1.12 IU/h each) of 125 I-labeled Actrapid insulin in each side of the abdominal wall. After 24 h of infusion, the size of the infused insulin depots was measured by external counting for 5 h. The basal infusion rate was then doubled in one side and halved in the other for the next 4 h. Finally, 1.12 IU/h of insulin was given in both sides of the abdominal wall for an additional 3 h. The changes in the size of the depots were measured, and the absorption rates for each hour were calculated. During the first 5 h of infusion, the depot size was almost constant (approximately 5 IU) with an absorption rate that equaled the infusion rate. Doubling the infusion rate led to a significant increase in depot size, but the absorption rate remained unchanged for the first 3 h, and only thereafter was a significant increase seen. When the infusion rate was reduced to the initial 1.12 IU/h, the absorption rate remained elevated during the next 3 h. Correspondingly, when the infusion rate was decreased, the depot size also decreased, but the absorption rate remained unchanged for the first 3 h. The results show that a change in the basal insulin infusion rate does not lead to any immediate change in the insulin absorption rate. This should be considered when planning an insulin-infusion program that includes alteration(s) in the basal-rate setting

  11. Thallium-201 infusion imaging

    International Nuclear Information System (INIS)

    Alazraki, N.; Kralios, A.; Wooten, W.W.

    1988-01-01

    To test the accuracy of Thallium-201 coronary artery infusion imaging of the earth during rapid changes in blood flow through a major coronary artery, the author performed a study in dogs correlating electromagnetic flow probe recordings with 201 Tl scintillation camera acquisitions. Hyperemic vascular response was produced experimentally in a major coronary artery by occlusion and release interventions which altered flow from baseline to zero during occlusion (20 seconds), followed by rapid flow increases approaching three times baseline immediately upon release of the occlusion. Flow returned to the baseline level within 60 seconds following release. Flow was also altered in a controlled fashion by other interventions. Recordings of Thallium uptake in the myocardium were displayed as a time histogram (counts per second squared vs time) which correlated very closely with electromagnetic flow probe recordings of flow (R=o.82-0.97). These experiments demonstrate a high degree of accuracy in Thallium infusion imaging to detect rapid changes in flow through a major coronary artery

  12. Installation design of pump motor control systems for supplied of the RSG-GAS secondary raw water cooling system

    International Nuclear Information System (INIS)

    Kiswanto; Teguh Sulistyo; M-Taufik

    2013-01-01

    It has designed already of an installation of the pump motor control system for supplied of raw water to fulfil the RSG-GAS secondary cooling system. The installation design of this plant is used to supply electrical energy from PLN and 3 phase generator to operate the pump motor embedded multilevel type, capacity, Q = 30 m 3 /h; electric power, PN = 4 kW; voltage, 380V/3-/50Hz, and Y connections that can be operated manually or automatically by using the automatic transfer switch. The results obtained recapitulation total load of 4 kW, the magnitude of the nominal current of 9.5 A; kind of safety and capacity are used NFB 16 A, use of this type of cable to the control panel is PLN NYY 6 mm 2 diameter maximum current capacity of 25 A cable and use the control panel to the pump motor cable type NYY 4 mm 2 diameter maximum current capacity of 20 A. The design of the pump motor control system installation is ready to be implemented. (author)

  13. Use of telemedicine improves glycemic control and quality of life in type 1 diabetes children on insulin pump therapy

    Directory of Open Access Journals (Sweden)

    Dmitry N. Laptev

    2018-02-01

    Full Text Available Rationale: Healthcare access plays a significant role in the improvement and maintaining of glycemic control and quality of life in type 1 diabetes mellitus (T1DM patients on continuous subcutaneous insulin infusion (CSII. Aims: The aim of the study was to evaluate the feasibility of remote support in children and adolescents with type 1 diabetes mellitus (T1DM and its effect on glycemic control and quality of life. Materials and methods: In 40 children and adolescents (13±2,7 years, 18/22 m/f on CSII with inadequately controlled T1DM (HbA1c≥7,5% we evaluated the effectiveness of telemedical support (TS, as compared with conventional support (CS. Parameters of glycemic control (HbA1c, average glycemia, SD, etc. and quality of a life were obtained on follow-up visits. Patients and their parents in ТМ group twice a month sent their insulin pump data using to CSII center and diabetologists sent back their advice via e-mail, phone or Skype. The primary end point was the change from the baseline HbA1c level and the proportion of patients achieving HbA1c of less than 7.5%. Results: At 24 weeks, the baseline mean HbA1c (8.7% in the two study groups had decreased to 7.7% in the TS group, as compared with 8.4% in the CS group (P0,05. Conclusion: In children with inadequately controlled T1DM, telemedical support proved to be feasible and resulted in significant improvement in glucose control (HbA1c, glucose variability and quality of life without the increase in the incidence of DKA and severe glycemia.

  14. Controlling a Conventional LS-pump based on Electrically Measured LS-pressure

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen; Andersen, Torben Ole; Hansen, Michael Rygaard

    2008-01-01

    As a result of the increasing use of sensors in mobile hydraulic equipment, the need for hydraulic pilot lines is decreasing, being replaced by electrical wiring and electrically controllable components. For controlling some of the existing hydraulic components there are, however, still a need...... this system, by either generating a copy of the LS-pressure, the LS-pressure being the output, or letting the output be the pump pressure. The focus of the current paper is on the controller design based on the first approach. Specifically a controlled leakage flow is used to avoid the need for a switching...

  15. Does transfusion of residual cardiopulmonary bypass circuit blood increase postoperative bleeding? A prospective randomized study in patients undergoing on pump cardiopulmonary bypass

    Science.gov (United States)

    Duara, Rajnish; Misra, Manoranjan; Bhuyan, Ritwick Raj; Sarma, P. Sankara; Jayakumar, Karunakaran

    2008-01-01

    Objective: Homologous blood transfusion after open heart surgery puts a tremendous load on the blood banks. This prospective randomized study evaluates the efficacy of infusing back residual cardiopulmonary bypass (CPB) circuit i.e., pump blood as a means to reduce homologous transfusion after coronary artery bypass surgery (CABG) and whether its use increases postoperative drainage. Materials and Methods: Sixty-seven consecutive patients who underwent elective CABGs under CPB were randomized into 2 groups: (1) cases where residual pump blood was used and (2) controls where residual pump blood was not used. Patients were monitored for hourly drainage on the day of surgery and the 1st postoperative day and the requirements of homologous blood and its products. Data were matched regarding change in Hemoglobin, Packed Cell Volume and coagulation parameters till 1st postoperative day. All cases were followed up for three years. Results: There was a marginal reduction in bleeding pattern in the early postoperative period in the cases compared to controls. The requirement of homologous blood and its products were also reduced in the cases. Conclusions: The use of CPB circuit blood is safe in the immediate postoperative period. The requirement of homologous blood transfusion can come down if strict transfusion criteria are maintained. PMID:20041077

  16. Does transfusion of residual cardiopulmonary bypass circuit blood increase postoperative bleeding? A prospective randomized study in patients undergoing on pump cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Duara Rajnish

    2008-01-01

    Full Text Available Objective: Homologous blood transfusion after open heart surgery puts a tremendous load on the blood banks. This prospective randomized study evaluates the efficacy of infusing back residual cardiopulmonary bypass (CPB circuit i.e., pump blood as a means to reduce homologous transfusion after coronary artery bypass surgery (CABG and whether its use increases postoperative drainage. Materials and Methods: Sixty-seven consecutive patients who underwent elective CABGs under CPB were randomized into 2 groups: (1 cases where residual pump blood was used and (2 controls where residual pump blood was not used. Patients were monitored for hourly drainage on the day of surgery and the 1 st postoperative day and the requirements of homologous blood and its products. Data were matched regarding change in Hemoglobin, Packed Cell Volume and coagulation parameters till 1st postoperative day. All cases were followed up for three years. Results: There was a marginal reduction in bleeding pattern in the early postoperative period in the cases compared to controls. The requirement of homologous blood and its products were also reduced in the cases. Conclusions: The use of CPB circuit blood is safe in the immediate postoperative period. The requirement of homologous blood transfusion can come down if strict transfusion criteria are maintained.

  17. International Space Station Active Thermal Control Sub-System On-Orbit Pump Performance and Reliability Using Liquid Ammonia as a Coolant

    Science.gov (United States)

    Morton, Richard D.; Jurick, Matthew; Roman, Ruben; Adamson, Gary; Bui, Chinh T.; Laliberte, Yvon J.

    2011-01-01

    The International Space Station (ISS) contains two Active Thermal Control Sub-systems (ATCS) that function by using a liquid ammonia cooling system collecting waste heat and rejecting it using radiators. These subsystems consist of a number of heat exchangers, cold plates, radiators, the Pump and Flow Control Subassembly (PFCS), and the Pump Module (PM), all of which are Orbital Replaceable Units (ORU's). The PFCS provides the motive force to circulate the ammonia coolant in the Photovoltaic Thermal Control Subsystem (PVTCS) and has been in operation since December, 2000. The Pump Module (PM) circulates liquid ammonia coolant within the External Active Thermal Control Subsystem (EATCS) cooling the ISS internal coolant (water) loops collecting waste heat and rejecting it through the ISS radiators. These PM loops have been in operation since December, 2006. This paper will discuss the original reliability analysis approach of the PFCS and Pump Module, comparing them against the current operational performance data for the ISS External Thermal Control Loops.

  18. An audit of hospital based outpatient infusions and a pilot program of community-based monoclonal antibody infusions.

    LENUS (Irish Health Repository)

    Doran, J-P

    2012-02-01

    INTRODUCTION: Infliximab, a chimeric monoclonal antibody to tumour necrosis factor alpha, is administered as an intravenous infusion requiring a costly hospital day case or inpatient admission. METHODS: An audit of all current therapies given by intravenous infusions in an outpatient setting in St Vincent\\'s University Hospital (SVUH) was undertaken. Furthermore, in conjunction with TCP homecare, we established in a general practise health clinic, the first Irish community infusion centre for the administration of infliximab in August 2006. RESULTS: All outpatient departments indicated that they would favour a centralized hospital infusion unit. There were no adverse events and the mean global satisfaction improved in the community infliximab infusion pilot programme of seven patients. CONCLUSION: This study suggests efficiencies in providing centralized infusion facilities, while the community based infusion of infliximab is feasible and safe in this small cohort and identifies the community infusion unit as a viable and cost efficient alternative for administration of infliximab.

  19. Analysis of the pump-beam path in corner-pumped slab laser

    International Nuclear Information System (INIS)

    Chen Li; Qiang Liu; Mali Gong; Gang Chen; Ping Yan

    2007-01-01

    The propagation of the pump radiation in active slab elements is considered. Conditions of the total internal reflection of the pump radiation are obtained, and are used to construct a series of graphical illustrations of reflection characteristics of different active elements. (control of laser radiation parameters)

  20. The satiety effects of intragastric macronutrient infusions in fatty and lean Zucker rats.

    Science.gov (United States)

    Maggio, C A; Greenwood, M R; Vasselli, J R

    1983-09-01

    To evaluate satiety in the hyperphagic, genetically obese Zucker "fatty" (fafa) rat, food-deprived fatty and lean (FaFa) control rats were given equicaloric intragastric infusions consisting largely of fat, carbohydrate, or protein. Relative to distilled water infusion, these infusions resulted in immediate reductions of food intake in both fatty and lean rats allowed to feed 20 min post-infusion. Cumulative food intakes remained reduced throughout the 2 hr period of observation. Thus, despite its hyperphagia, the fatty rat is responsive to the satiating effect of infused nutrients. However, the relative satiating effectiveness of the macronutrient infusions differed for the two genotypes. In lean rats, the different macronutrient infusions resulted in equivalent reductions of feeding. In contrast, in fatty rats, fat was the least satiating and protein was the most satiating macronutrient. Moreover, compared to lean rats, fatty rats displayed less initial suppression of feeding after fat infusion and greater overall suppression after protein infusion. These effects are consistent with the long-term feeding behavior of the fatty rat for the different macronutrients and may be related to pre- and postabsorptive metabolic alterations that have been documented in this animal.

  1. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid X

    International Nuclear Information System (INIS)

    HORNER, T.M.

    2001-01-01

    This document describes the software programs for the Allen-Bradley SLC 500 programmable logic controller (PLC) and the Allen-Bradley DTAM PLUS operator interface module used on Pumping Instrumentation and Control (PIC) skid ''X''. The software programs for the SLC 500 and DTAM Plus are based on the core programs provided by Allen-Bradley. The PLC and DTAM software programs on skid ''D'' for SX-104 are the baseline programs. These baselines will be tailored for each individual BY-farm skid. An Acceptance Test Procedure (ATP) and an Operational Test Procedure (OTP) verify that the software programs meet the specific requirements for BY-105 pumping. This document represents the final PLC and DTAM programs for PIC skid ''X'' at BY-105. These programs were printed out after the performance of the OTP. The OTP acts as the final qualification test for the software programs. Functional requirements and details of the PLC ladder logic are described in this document. The final programs entered into the PLC and DTAM Plus are included as Appendices to this document

  2. Analog Fixed Maximum Power Point Control for a PWM Step-downConverter for Water Pumping Installations

    DEFF Research Database (Denmark)

    Beltran, H.; Perez, E.; Chen, Zhe

    2009-01-01

    This paper describes a Fixed Maximum Power Point analog control used in a step-down Pulse Width Modulated power converter. The DC/DC converter drives a DC motor used in small water pumping installations, without any electric storage device. The power supply is provided by PV panels working around....... The proposed Optimal Power Point fix voltage control system is analyzed in comparison to other complex controls....... their maximum power point, with a fixed operating voltage value. The control circuit implementation is not only simple and cheap, but also robust and reliable. System protections and adjustments are also proposed. Simulations and hardware are reported in the paper for a 150W water pumping application system...

  3. TFCX pumped limiter and vacuum pumping system design and analysis

    International Nuclear Information System (INIS)

    Haines, J.R.

    1985-04-01

    Impurity control system design and performance studies were performed in support of the Tokamak Fusion Core Experiment (TFCX) pre-conceptual design. Efforts concentrated on pumped limiter and vacuum pumping system design configuration, thermal/mechanical and erosion lifetime performance of the limiter protective surface, and helium ash removal performance. The reference limiter design forms a continuous toroidal belt at the bottom of the device and features a flat surface with a single leading edge. The vacuum pumping system features large vacuum ducts (diameter approximately 1 m) and high-speed, compound cryopumps. Analysis results indicate that the limiter/vacuum pumping system design provides adequate helium ash removal. Erosion, primarily by disruption-induced vaporization and/or melting, limits the protective surface lifetime to about one calendar year or only about 60 full-power hours of operation. In addition to evaluating impurity control system performance for nominal TFCX conditions, these studies attempt to focus on the key plasma physics and engineering design issues that should be addressed in future research and development programs

  4. Successful treatment of young infants presenting neonatal diabetes mellitus with continuous subcutaneous insulin infusion before genetic diagnosis.

    Science.gov (United States)

    Rabbone, Ivana; Barbetti, Fabrizio; Marigliano, Marco; Bonfanti, Riccardo; Piccinno, Elvira; Ortolani, Federica; Ignaccolo, Giovanna; Maffeis, Claudio; Confetto, Santino; Cerutti, Franco; Zanfardino, Angela; Iafusco, Dario

    2016-08-01

    Neonatal diabetes mellitus (NDM) is defined as hyperglycemia and impaired insulin secretion with onset within 6 months of birth. While rare, NDM presents complex challenges regarding the management of glycemic control. The availability of continuous subcutaneous insulin infusion pumps (CSII) in combination with continuous glucose monitoring systems (CGM) provides an opportunity to monitor glucose levels more closely and deliver insulin more safely. We report four cases of young infants with NDM successfully treated with CSII and CGM. Moreover, in two cases with Kir 6.2 mutation, we describe the use of CSII in switching therapy from insulin to sulfonylurea treatment. Insulin pump requirement for the 4 neonatal diabetes cases was the same regardless of disease pathogenesis and c-peptide levels. No dilution of insulin was needed. The use of an integrated CGM system helped in a more precise control of BG levels with the possibility of several modifications of insulin basal rates. Moreover, as showed in the first two case-reports, when the treatment was switched from insulin to glibenclamide, according to identification of Kir 6.2 mutation and diagnosis of NPDM, the CSII therapy demonstrated to be helpful in allowing gradual insulin suspension and progressive introduction of sulfonylurea. During the neonatal period, the use of CSII therapy is safe, more physiological, accurate and easier for the insulin administration management. Furthermore, CSII therapy is safe during the switch of therapy from insulin to glibenclamide for infants with permanent neonatal diabetes mellitus.

  5. Bronchial arterial infusion versus bronchial combined pulmonary arterial infusion for pulmonary metastatic tumors

    International Nuclear Information System (INIS)

    Dong Sheng; Dong Weihua; Jia Ningyang; Zhang Dianbo; Xiao Xiangsheng

    2008-01-01

    Objective: To evaluate the pulmonary metastatic tumor response to different ways of transcatheter arterial infusion. Methods: Thirty-five patients with pulmonary metastatic tumors were randomized divided into two groups: 15 patients with 49 lesions treated with bronchial arterial infusion (BAI) and 20 patients with 65 lesions treated with bronchial arterial infusion (BM)combined with pulmonary arterial infusion (PAI). The therapeutic response was assessed by the WHO evaluation criteria. Results: The total effective rate(CR + PR) of BAI was 65.3% (32/49), PAI + BAI was 61.5%(40/65) showing no statistical difference. The median survival time of BAI was 9 mo, BAI + PAI was 11.5 mo, demonstrating no statistical significance. Conclusions: BAI should be the primary treatment for pulmonary metastatic tumor. (authors)

  6. Gradual withdrawal of remifentanil infusion may prevent opioid-induced hyperalgesia.

    Science.gov (United States)

    Comelon, M; Raeder, J; Stubhaug, A; Nielsen, C S; Draegni, T; Lenz, H

    2016-04-01

    The aim of this study was to examine if gradual withdrawal of remifentanil infusion prevented opioid-induced hyperalgesia (OIH) as opposed to abrupt withdrawal. OIH duration was also evaluated. Nineteen volunteers were enrolled in this randomized, double-blinded, placebo-controlled, crossover study. All went through three sessions: abrupt or gradual withdrawal of remifentanil infusion and placebo. Remifentanil was administered at 2.5 ng ml(-1) for 30 min before abrupt withdrawal or gradual withdrawal by 0.6 ng ml(-1) every five min. Pain was assessed at baseline, during infusion, 45-50 min and 105-110 min after end of infusions using the heat pain test (HPT) and the cold pressor test (CPT). The HPT 45 min after infusion indicated OIH development in the abrupt withdrawal session with higher pain scores compared with the gradual withdrawal and placebo sessions (both Pwithdrawal compared with placebo (P=0.93). In the CPT 50 min after end of infusion there was OIH in both remifentanil sessions compared with placebo (gradual P=0.01, abrupt Pwithdrawal of remifentanil infusion in the HPT. After abrupt withdrawal OIH was present in the HPT. In the CPT there was OIH after both gradual and abrupt withdrawal of infusion. The duration of OIH was less than 105 min for both pain modalities. NCT 01702389. EudraCT number 2011-002734-39. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Type of homogenization and fat loss during continuous infusion of human milk.

    Science.gov (United States)

    García-Lara, Nadia Raquel; Escuder-Vieco, Diana; Alonso Díaz, Clara; Vázquez Román, Sara; De la Cruz-Bértolo, Javier; Pallás-Alonso, Carmen Rosa

    2014-11-01

    Substantial fat loss may occur during continuous feeding of human milk (HM). A decrease of fat loss has been described following homogenization. Well-established methods of homogenization of HM for routine use in the neonatal intensive care unit (NICU) would be desirable. We compared the loss of fat based on the use of 3 different methods for homogenizing thawed HM during continuous feeding. Sixteen frozen donor HM samples were thawed, homogenized with ultrasound and separated into 3 aliquots ("baseline agitation," "hourly agitation," and "ultrasound"), and then frozen for 48 hours. Aliquots were thawed again and a baseline agitation was applied. Subsequently, aliquots baseline agitation and hourly agitation were drawn into a syringe, while ultrasound was applied to aliquot ultrasound before it was drawn into a syringe. The syringes were loaded into a pump (2 mL/h; 4 hours). At hourly intervals the hourly agitation infusion was stopped, the syringe was disconnected and gently shaken. During infusion, samples from the 3 groups were collected hourly for analysis of fat and caloric content. The 3 groups of homogenization showed similar fat content at the beginning of the infusion. For fat, mean (SD) hourly changes of -0.03 (0.01), -0.09 (0.01), and -0.09 (0.01) g/dL were observed for the hourly agitation, baseline agitation, and ultrasound groups, respectively. The decrease was smaller for the hourly agitation group (P homogenization is used. © The Author(s) 2014.

  8. Patient Controlled Epidural Analgesia during Labour: Effect of Addition of Background Infusion on Quality of Analgesia & Maternal Satisfaction

    Directory of Open Access Journals (Sweden)

    Uma Srivastava

    2009-01-01

    Full Text Available Patient controlled epidural analgesia (PCEA is a well established technique for pain relief during labor. But the inclusion of continuous background infusion to PCEA is controversial. The aim of this study was to assess whether the use of continuous infusion along with PCEA was beneficial for laboring women with regards to quality of analgesia, maternal satisfaction and neonatal outcome in comparison to PCEA alone. Fifty five parturients received epidural bolus of 10ml solution containing 0.125% bupivacaine +2 ìg.ml-1 of fentanyl. For maintenance of analgesia the patients of Group PCEA self administered 8 ml bolus with lockout interval of 20 minutes of above solution on demand with no basal infusion. While the patients of Group PCEA + CI received continuous epidural infusion at the rate of 10 ml.hr-1 along with self administered boluses of 3 ml with lockout interval of 10 minutes of similar epidural solution. Patients of both groups were given rescue boluses by the anaesthetists for distressing pain. Verbal analogue pain scores, incidence of distressing pain, need of supplementary/rescue boluses, dose of bupivacaine consumed, maternal satisfaction and neonatal Apgar scores were recorded. No significant difference was observed between mean VAS pain scores during labor, maternal satisfaction, mode of delivery or neonatal Apgar scores. But more patients (n=8 required rescue boluses in PCEA group for distressing pain. The total volume consumed of bupivacaine and opioid was slightly more in PCEA + CI group. In both the techniques the highest sensory level, degree of motor block were comparable& prolongation of labor was not seen. It was concluded that both the techniques provided equivalent labor analgesia, maternal satisfaction and neonatal Apgar scores. PCEA along with continuous infusion at the rate of 10 ml/ hr resulted in lesser incidence of distressing pain and need for rescue analgesic. Although this group consumed higher dose of bupivacaine

  9. A prospective, randomized, blinded-endpoint, controlled study – continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia

    Directory of Open Access Journals (Sweden)

    Joana Nunes

    2016-09-01

    Full Text Available Background: There is evidence that administration of a programmed intermittent epidural bolus (PIEB compared to continuous epidural infusion (CEI leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. Methods: In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10 mL with Ropivacaine 0.16% plus Sufentanil 10 μg, parturient were randomly assigned to one of three regimens: A – Ropivacaine 0.15% plus Sufentanil 0.2 μg/mL solution as continuous epidural infusion (5 mL/h, beginning immediately after the initial bolus; B – Ropivacaine 0.1% plus Sufentanil 0.2 μg/mL as programmed intermittent epidural bolus and C – Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10 mL/h starting 60 min after the initial bolus. Rescue boluses of 5 mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. Results: We analyzed 130 pregnants (A = 60; B = 33; C = 37. The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p = 0.83. We found a higher caesarean delivery rate in group A (56.7%; p = 0.02. No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Conclusions: Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes. Resumo: Justificativa: Há evidências de que a administração de um bolus epidural intermitente programado (BEIP comparada à infusão epidural contínua (IEC resulta em maior eficácia da analgesia e da satisfação materna, com redução das intervenções anestésicas. Métodos: Neste estudo, 166

  10. Development of a standardized, citywide process for managing smart-pump drug libraries.

    Science.gov (United States)

    Walroth, Todd A; Smallwood, Shannon; Arthur, Karen; Vance, Betsy; Washington, Alana; Staublin, Therese; Haslar, Tammy; Reddan, Jennifer G; Fuller, James

    2018-06-15

    Development and implementation of an interprofessional consensus-driven process for review and optimization of smart-pump drug libraries and dosing limits are described. The Indianapolis Coalition for Patient Safety (ICPS), which represents 6 Indianapolis-area health systems, identified an opportunity to reduce clinically insignificant alerts that smart infusion pumps present to end users. Through a consensus-driven process, ICPS aimed to identify best practices to implement at individual hospitals in order to establish specific action items for smart-pump drug library optimization. A work group of pharmacists, nurses, and industrial engineers met to evaluate variability within and lack of scrutiny of smart-pump drug libraries. The work group used Lean Six Sigma methodologies to generate a list of key needs and barriers to be addressed in process standardization. The group reviewed targets for smart-pump drug library optimization, including dosing limits, types of alerts reviewed, policies, and safety best practices. The work group also analyzed existing processes at each site to develop a final consensus statement outlining a model process for reviewing alerts and managing smart-pump data. Analysis of the total number of alerts per device across ICPS-affiliated health systems over a 4-year period indicated a 50% decrease (from 7.2 to 3.6 alerts per device per month) after implementation of the model by ICPS member organizations. Through implementation of a standardized, consensus-driven process for smart-pump drug library optimization, ICPS member health systems reduced clinically insignificant smart-pump alerts. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  11. Acceptance Test Procedure for New Pumping and Instrumentation Control Skid M

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This Acceptance Test Procedure (ATP) verifies proper construction per the design drawings and tests for proper functioning of the Pumping and Instrumentation Control (PIC) skid ''M''. The Scope section lists the systems and functions to be checked. This ATP will be performed at the Site Fabrication Service's (SFS) shop upon completion of construction of the PIC skid

  12. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''V''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) verifies proper construction per the design drawings and tests for proper functioning of the Pumping Instrumentation and Control (PIC) skid ''V''. The scope section lists the systems and functions to be checked. This ATP will be performed at the Site Fabrication Services (SFS) shop upon completion of the construction of the PIC skid

  13. Effect of steel and teflon infusion catheters on subcutaneous adipose tissue blood flow and infusion counter pressure in humans

    DEFF Research Database (Denmark)

    Højbjerre, Lise; Skov-Jensen, Camilla; Kaastrup, Peter

    2009-01-01

    BACKGROUND: Subcutaneous tissue is an important target for drug deposition or infusion. A local trauma may induce alterations in local microcirculation and diffusion barriers with consequences for drug bioavailability. We examined the influence of infusion catheters' wear time on local...... microcirculation and infusion counter pressure. METHODS: One steel catheter and one Teflon (Dupont, Wilmington, DE) catheter were inserted in subcutaneous, abdominal adipose tissue (SCAAT) in 10 healthy, lean men. The catheters were infused with isotonic saline at a rate of 10 microL/h for 48 h. Another steel...... catheter and a Teflon catheter were inserted contralateral to the previous catheters after 48 h. The infusion counter pressure was measured during a basal infusion rate followed by a bolus infusion. The measurements during a basal rate infusion were repeated after the bolus infusion. Adipose tissue blood...

  14. Reactor recirculation pump test loop

    International Nuclear Information System (INIS)

    Taka, Shusei; Kato, Hiroyuki

    1979-01-01

    A test loop for a reactor primary loop recirculation pumps (PLR pumps) has been constructed at Ebara's Haneda Plant in preparation for production of PLR pumps under license from Byron Jackson Pump Division of Borg-Warner Corporation. This loop can simulate operating conditions for test PLR pumps with 130 per cent of the capacity of pumps for a 1100 MWe BWR plant. A main loop, primary cooling system, water demineralizer, secondary cooling system, instrumentation and control equipment and an electric power supply system make up the test loop. This article describes the test loop itself and test results of two PLR pumps for Fukushima No. 2 N.P.S. Unit 1 and one main circulation pump for HAZ Demonstration Test Facility. (author)

  15. Prospective, randomized, and controlled trial on ketamine infusion during bilateral axillo-breast approach (BABA) robotic or endoscopic thyroidectomy: Effects on postoperative pain and recovery profiles

    Science.gov (United States)

    Kim, Dong-Ho; Choi, June Young; Kim, Byoung-Gook; Hwang, Jin-Young; Park, Seong-Joo; Oh, Ah-Young; Jeon, Young-Tae; Ryu, Jung-Hee

    2016-01-01

    Abstract Background: Robotic or endoscopic thyroidectomy using bilateral axillo-breast approach (BABA) is frequently performed for excellent cosmesis. However, postoperative pain is remained as concerns due to the extent tissue dissection and tension during the operation. Ketamine is a noncompetitive N-methyl-d-aspartate (NMDA) receptor antagonist that reduces acute postoperative pain. We evaluated the effects of intraoperative ketamine infusion on postoperative pain control and recovery profiles following BABA robotic or endoscopic thyroidectomy. Methods: Fifty-eight adult patients scheduled for BABA robotic or endoscopic thyroidectomy were randomized into a control group (n = 29) and ketamine group (n = 29). Following induction of anesthesia, patients in each group were infused with the same volume of saline or ketamine solution (1 mg/kg bolus, 60 μg/kg/h continuous infusion). Total intravenous anesthesia with propofol and remifentanil was used to induce and maintain anesthesia. Pain scores (101-point numerical rating scale, 0 = no pain, 100 = the worst imaginable pain), the consumption of rescue analgesics, and other postoperative adverse effects were assessed at 1, 6, 24, and 48 hours postoperatively. Results: Patients in the ketamine group reported lower pain scores than those in the control group at 6 hours (30 [30] vs 50 [30]; P = 0.017), 24 hours (20 [10] vs 30 [20]; P ketamine infusion during anesthesia resulted in lower postoperative pain scores following BABA robotic or endoscopic thyroidectomy, with no increase in adverse events. PMID:27930531

  16. Evaluation of Manufacturability of Embedded Sensors and Controls with Canned Rotor Pump System

    Energy Technology Data Exchange (ETDEWEB)

    Kisner, Roger A [ORNL; Fugate, David L [ORNL; Melin, Alexander M [ORNL; Holcomb, David Eugene [ORNL; Wilson, Dane F [ORNL; Silva, Pamela C [ORNL; Cruz Molina, Carola [ORNL

    2013-07-01

    This report documents the current status of fabrication and assembly planning for the magnetic bearing, canned rotor pump being used as a demonstration platform for deeply integrating I&C into nuclear power plant components. The report identifies material choices and fabrication sequences for all of the required parts and the issues that need to be either resolved or accommodated during the manufacturing process. Down selection between material options has not yet been performed. Potential suppliers for all of the necessary materials have also been identified. The assembly evaluation begins by logically subdividing the pump into modules, which are themselves decomposed into individual parts. Potential materials and fabrication processes for each part in turn are then evaluated. The evaluation process includes assessment of the environmental compatibility requirements and the tolerances available for the selected fabrication processes. A description of the pump power/control electronics is also provided. The report also includes exploded views of the modules that show the integration of the various parts into modules that are then assembled to form the pump. Emphasis has been placed on thermal environment compatibility and the part dimensional changes during heat-up. No insurmountable fabrication or assembly challenges have been identified.

  17. Integrated real time control of influent pumping station and primary settling tanks at WWTP Eindhoven

    NARCIS (Netherlands)

    van Daal-Rombouts, P.M.M.; de Jonge, J; Langeveld, J.G.; Clemens, F.H.L.R.

    2016-01-01

    This research deals with the design and implementation of an integrated control for the WWTP of Eindhoven. The control influences the operation of the primary settling tanks and influent pumping station to reduce reduce ammonia peaks in the WWTP effluent. The control takes into account the treatment

  18. A water pumping control system with a programmable logic controller (PLC) and industrial wireless modules for industrial plants--an experimental setup.

    Science.gov (United States)

    Bayindir, Ramazan; Cetinceviz, Yucel

    2011-04-01

    This paper describes a water pumping control system that is designed for production plants and implemented in an experimental setup in a laboratory. These plants contain harsh environments in which chemicals, vibrations or moving parts exist that could potentially damage the cabling or wires that are part of the control system. Furthermore, the data has to be transferred over paths that are accessible to the public. The control systems that it uses are a programmable logic controller (PLC) and industrial wireless local area network (IWLAN) technologies. It is implemented by a PLC, an communication processor (CP), two IWLAN modules, and a distributed input/output (I/O) module, as well as the water pump and sensors. Our system communication is based on an Industrial Ethernet and uses the standard Transport Control Protocol/Internet Protocol for parameterisation, configuration and diagnostics. The main function of the PLC is to send a digital signal to the water pump to turn it on or off, based on the tank level, using a pressure transmitter and inputs from limit switches that indicate the level of the water in the tank. This paper aims to provide a convenient solution in process plants where cabling is not possible. It also has lower installation and maintenance cost, provides reliable operation, and robust and flexible construction, suitable for industrial applications. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  19. Skeletal Muscle Pump Drives Control of Cardiovascular and Postural Systems

    Science.gov (United States)

    Verma, Ajay K.; Garg, Amanmeet; Xu, Da; Bruner, Michelle; Fazel-Rezai, Reza; Blaber, Andrew P.; Tavakolian, Kouhyar

    2017-03-01

    The causal interaction between cardio-postural-musculoskeletal systems is critical in maintaining postural stability under orthostatic challenge. The absence or reduction of such interactions could lead to fainting and falls often experienced by elderly individuals. The causal relationship between systolic blood pressure (SBP), calf electromyography (EMG), and resultant center of pressure (COPr) can quantify the behavior of cardio-postural control loop. Convergent cross mapping (CCM) is a non-linear approach to establish causality, thus, expected to decipher nonlinear causal cardio-postural-musculoskeletal interactions. Data were acquired simultaneously from young participants (25 ± 2 years, n = 18) during a 10-minute sit-to-stand test. In the young population, skeletal muscle pump was found to drive blood pressure control (EMG → SBP) as well as control the postural sway (EMG → COPr) through the significantly higher causal drive in the direction towards SBP and COPr. Furthermore, the effect of aging on muscle pump activation associated with blood pressure regulation was explored. Simultaneous EMG and SBP were acquired from elderly group (69 ± 4 years, n = 14). A significant (p = 0.002) decline in EMG → SBP causality was observed in the elderly group, compared to the young group. The results highlight the potential of causality to detect alteration in blood pressure regulation with age, thus, a potential clinical utility towards detection of fall proneness.

  20. Cascade fuzzy control for gas engine driven heat pump

    International Nuclear Information System (INIS)

    Li Shuze; Zhang Wugao; Zhang Rongrong; Lv Dexu; Huang Zhen

    2005-01-01

    In addition to absorption chillers, today's gas cooling technology includes gas engine driven heat pump systems (GEHP) in a range of capacities and temperature capacities suitable for most commercial air conditioning and refrigeration applications. Much is expected from GEHPs as a product that would help satisfy the air conditioning system demand from medium and small sized buildings, restrict electric power demand peaks in summer and save energy in general. This article describes a kind of control strategy for a GEHP, a cascade fuzzy control. GEHPs have large and varying time constants and their dynamic modeling cannot be easily achieved. A cascade control strategy is effective for systems that have large time constants and disturbances, and a fuzzy control strategy is fit for a system that lacks an accurate model. This cascade fuzzy control structure brings together the best merits of fuzzy control and cascade control structures. The performance of the cascade fuzzy control is compared to that of a cascade PI (proportional and integral) control strategy, and it is shown by example that the cascade fuzzy control strategy gives a better performance, reduced reaction time and smaller overshoot temperature

  1. Sodium pumping: pump problems

    International Nuclear Information System (INIS)

    Guer, M.; Guiton, P.

    Information on sodium pumps for LMFBR type reactors is presented concerning ring pump design, pool reactor pump design, secondary pumps, sodium bearings, swivel joints of the oscillating annulus, and thermal shock loads

  2. The analgesic efficacy of intravenous lidocaine infusion after laparoscopic fundoplication: a prospective, randomized, double-blind, placebo-controlled trial

    Directory of Open Access Journals (Sweden)

    Dale GJ

    2016-12-01

    Full Text Available Gregory J Dale,1 Stephanie Phillips,2 Gregory L Falk3 1Westmead Hospital Clinical School, The University of Sydney, 2Sydney Adventist Hospital Clinical School, The University of Sydney, 3Concord Clinical School, The University of Sydney, Sydney, Australia Abstract: This study aimed to determine if intravenous lidocaine infusion reduces postoperative pain intensity following laparoscopic fundoplication surgery and to also validate the safety of intravenous lidocaine at the dose tested. This was an equally randomized, double-blind, placebo-controlled, parallel-group, single center trial. Adult patients undergoing laparoscopic fundoplication were recruited. The intervention group received 1 mg/kg intravenous lidocaine bolus prior to induction of anesthesia, then an intravenous infusion at 2 mg/kg/h for 24 hours. The primary outcome was pain, measured using a numeric rating scale for 30 hours postoperatively. Secondary outcomes were nausea and vomiting, opioid requirements, adverse events, serum lidocaine concentration, and length of hospital stay. The study was terminated after an interim analysis of 24 patients showed evidence of futility. There was no difference in postoperative pain scores (lidocaine versus control, mean ± standard deviation at rest (2.0 ± 2.7 vs 2.1 ± 2.4, P=0.286 or with movement (2.0 ± 2.6 vs 2.6 ± 2.7, P=0.487. Three adverse events occurred in the lidocaine group (25% of patients. Intravenous lidocaine did not provide clinically significant analgesia to patients undergoing laparoscopic fundoplication. The serum lidocaine concentration of patients who experienced adverse events were within the therapeutic range. This trial cannot confirm the safety of intravenous lidocaine at the dose tested. Keywords: analgesia, local anesthetics, intravenous infusions, pharmacokinetics

  3. Assistance algorithm of nursing for amiodarone intravenous infusion

    Directory of Open Access Journals (Sweden)

    Francimar Tinoco de Oliveira

    2014-12-01

    Full Text Available This study aimed at identifying scientific publication on phlebitis caused by amiodarone and proposes a nursing care algorithm for interventions in intravenous amiodarone administration grounded in the Infusion Nursing Society and the Center for Disease Control and Prevention. It is a descriptive study mediated by integrative review in MedLine, LILACS, IBECS, BDENF, Cochrane Library and Scielo bases, published from 2006 to 2013. The sample consisted of nine articles. The evidence pointed the incidence of phlebitis due to the infusion of amiodarone and the need to control this event. The algorithm proposed shows the materials to be used and the procedure of drug administration in order to minimize injury. Besides subsidizing the development of future studies, this algorithm also promotes the incorporation of the best recommendation for the interventionist clinical practice.

  4. Nonlinear force feedback control of piezoelectric-hydraulic pump actuator for automotive transmission shift control

    Science.gov (United States)

    Kim, Gi-Woo; Wang, K. W.

    2008-03-01

    In recent years, researchers have investigated the feasibility of utilizing piezoelectric-hydraulic pump based actuation systems for automotive transmission controls. This new concept could eventually reduce the complexity, weight, and fuel consumption of the current transmissions. In this research, we focus on how to utilize this new approach on the shift control of automatic transmissions (AT), which generally requires pressure profiling for friction elements during the operation. To illustrate the concept, we will consider the 1--> 2 up shift control using band brake friction elements. In order to perform the actuation force tracking for AT shift control, nonlinear force feedback control laws are designed based on the sliding mode theory for the given nonlinear system. This paper will describe the modeling of the band brake actuation system, the design of the nonlinear force feedback controller, and simulation and experimental results for demonstration of the new concept.

  5. Method and apparatus for protection of pump systems

    International Nuclear Information System (INIS)

    Youngborg, L.H.

    1987-01-01

    This patent describes a nuclear power plant having a fluid-filler reactor vessel with a vapor outflow line for removing vapor from the reactor vessel, and liquid inflow means for injecting liquid to the reactor vessel. The inflow means includes an inflow line, a centrifugal pump disposed along the inflow line having an inlet and an outlet, an induction motor to drive the pump, flow control means along the inflow line between the pump and the reactor vessel from the pump. A means is included for generating a first control signal in response to liquid level in the reactor vessel and net vapor outflow versus liquid inflow with respect to the reactor vessel, the first control signal generating means being effective to generate a first signal to open and a second signal to close the flow control means to maintain liquid level in the vessel within predetermined limits. A pump and pump motor protection apparatus is described comprising: means for measuring the pressure of the liquid in the inlet of the pump; means for measuring the temperature of the liquid in the inlet of the pump; means for determining a required subcooling for the pump at the instantaneous temperature of the liquid in the inlet of the pump; and means for determining the enthalpy of the liquid in the inlet of the pump from the pressure and temperature of the liquid

  6. The control of convection by fuelling and pumping in the JET pumped divertor

    Energy Technology Data Exchange (ETDEWEB)

    Harbour, P J; Andrew, P; Campbell, D; Clement, S; Davies, S; Ehrenberg, J; Erents, S K; Gondhalekar, A; Gadeberg, M; Gottardi, N; Von Hellermann, M; Horton, L; Loarte, A; Lowry, C; Maggi, C; McCormick, K; O` Brien, D; Reichle, R; Saibene, G; Simonini, R; Spence, J; Stamp, M; Stork, D; Taroni, A; Vlases, G [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking

    1994-07-01

    Convection from the scrape-off layer (SOL) to the divertor will control core impurities, if it retains them in a cold, dense, divertor plasma. This implies a high impurity concentration in the divertor, low at its entrance. Particle flux into the divertor entrance can be varied systematically in JET, using the new fuelling and pumping systems. The convection ratio has been estimated for various conditions of operation. Particle convection into the divertor should increase thermal convection, decreasing thermal conduction, and temperature and density gradients along the magnetic field, hence increasing the frictional force and decreasing the thermal force on impurities. Changes in convection in the SOL, caused by gaseous fuelling, have been studied, both experimentally in the JET Mk I divertor and with EDGE2/NIMBUS. 1 ref., 4 figs., 1 tab.

  7. Hippocampal infusions of glucose reverse memory deficits produced by co-infusions of a GABA receptor agonist.

    Science.gov (United States)

    Krebs-Kraft, Desiree L; Parent, Marise B

    2008-02-01

    Although septal infusions of glucose typically have positive effects on memory, we have shown repeatedly that this treatment exacerbates memory deficits produced by co-infusions of gamma-aminobutyric acid (GABA) receptor agonists. The present experiments tested whether this negative interaction between glucose and GABA in the medial septum would be observed in the hippocampus, a brain region where glucose typically has positive effects on memory. Specifically, we determined whether hippocampal infusions of glucose would reverse or exacerbate memory deficits produced by hippocampal co-infusions of the GABA receptor agonist muscimol. Fifteen minutes prior to either assessing spontaneous alternation (SA) or continuous multiple trial inhibitory avoidance (CMIA) training, male Sprague-Dawley-derived rats were given bilateral hippocampal infusions of vehicle (phosphate-buffered saline [PBS], 1 microl/2 min), glucose (33 or 50 nmol), muscimol (0.3 or 0.4 microg, SA or 3 microg, CMIA) or muscimol and glucose combined in one solution. The results indicated that hippocampal infusions of muscimol alone decreased SA scores and CMIA retention latencies. More importantly, hippocampal infusions of glucose, at doses that had no effect when infused alone, attenuated (33 nmol) or reversed (50 nmol) the muscimol-induced memory deficits. Thus, although co-infusions of glucose with muscimol into the medial septum impair memory, the present findings show that an opposite effect is observed in the hippocampus. Collectively, these findings suggest that the memory-impairing interaction between glucose and GABA in the medial septum is not a general property of the brain, but rather is brain region-dependent.

  8. Subcutaneous infusion in palliative care: a focus on the neria soft 90 infusion set.

    Science.gov (United States)

    Gabriel, Janice

    2014-11-01

    Subcutaneous administration of medications and/or fluids can play a crucial part in supporting patients at home and thereby avoiding the need for hospitalisation. It is an area of patient care that has received little attention compared with other types of parenteral therapies. However, it is an effective and safe route for continuous administration for individuals requiring palliative care. Technological advancements have led to improved subcutaneous infusion devices, such as fine-gauge cannulae with integral sharps protection, as well as integral hypoallergenic dressings. These design features not only help to increase patient comfort but also minimise the potential for needlestick injuries, as well as providing the health professional with one sterile package containing all of the components needed to establish subcutaneous infusion. However, technological developments alone are insufficient to improve patient outcomes. Knowledge of the individual patient, together with their diagnosis and intended treatment, will influence the choice of subcutaneous infusion device, with the overall aim of minimising the potential for complications and improving comfort. This paper provides an overview of subcutaneous infusion, including the importance of patient assessment and the education and training needs of health professionals, and then focuses on one specific subcutaneous infusion device: the neria soft 90 infusion set.

  9. Dextrose boluses versus burette dextrose infusions in prevention of hypoglycemia among preterms admitted at Mulago Hospital: an open label randomized clinical trial.

    Science.gov (United States)

    Kutamba, E; Lubega, S; Mugalu, J; Ouma, J; Mupere, E

    2014-09-01

    Hypoglycemia is a major cause of morbidity and mortality among preterm infants and its management remains a challenge in resource limited settings. Use of dextrose infusion by the recommended infusion pumps is not feasible in our environment due to their high costs and yet the current use of mini dextrose boluses with syringes as adapted at Mulago national referral and tertiary teaching hospital has unknown efficacy in prevention of hypoglycemia. We determined the efficacy of dextrose infusions by burettes versus two hourly dextrose boluses in prevention of hypoglycemia among preterms admitted in the first 72 hours at Special Care Unit, Mulago Hospital. One hundred and forty preterms aged 0 to 24 hours of life were randomized to receive 10% IV dextrose either as mini boluses or by infusion using burettes in an open label clinical trial. Blood glucose was measured at 0, two hourly for next 6 hours, 6 hourly for next 12 hours and thereafter 12 hourly until end of 72 hours following admission. Primary end point was incidence of hypoglycemia (random blood sugar (RBS) dextrose infusion was computed using 1-RR. From February 2012 to April 2012, 68 preterms in the bolus arm and 72 in the infusion arm were studied. Hypoglycemia was detected in 34% (48/140). The incidence of hypoglycemia in the bolus arm was 59% (40/68) compared to 11% (8/72) in the infusion arm (RR; 0.19, 95% CI; 0.09-0.37). Efficacy (1-RR) of infusion by burettes versus boluses in prevention of hypoglycemia among preterms was 0.81 (95% CI; 0.63-0.90). Continuous 10% dextrose infusion by burettes reduced the incidence of hypoglycemia by 81% in the first 72 hours of admission compared to two hourly 10% mini dextrose boluses among preterms admitted at Special Care Unit, Mulago Hospital. (ClinicalTrials.gov Identifier: NCT01688674).

  10. Metabolic control after years of completing a clinical trial on sensor-augmented pump therapy.

    Science.gov (United States)

    Quirós, Carmen; Giménez, Marga; Orois, Aida; Conget, Ignacio

    2015-11-01

    Sensor-augmented pump (SAP) therapy has been shown to be effective and safe for improving metabolic control in patients with type 1 diabetes mellitus (T1DM) in a number of trials. Our objective was to assess glycemic control in a group of T1DM patients on insulin pump or SAP therapy after years of participating in the SWITCH (Sensing With Insulin pump Therapy To Control HbA1c) trial and their return to routine medical monitoring. A retrospective, observational study of 20 patients who participated in the SWITCH trial at our hospital from 2008 to 2010. HbA1c values were compared at the start, during (at the end of the periods with/without SAP use - Sensor On/Sensor Off period respectively - of the cross-over design), and 3 years after study completion. HbA1c values of patients who continued SAP therapy (n=6) or only used insulin pump (n=14) were also compared. Twenty patients with T1DM (44.4±9.3 years, 60% women, baseline HbA1c level 8.43±0.55%) were enrolled into the SWITCH study). Three years after study completion, HbA1c level was 7.79±0.77 in patients on pump alone, with no significant change from the value at the end of the Off period of the study (7.85±0.57%; p=0.961). As compared to the end of the On period, HbA1c worsened less in patients who remained on SAP than in those on pump alone (0.18±0.42 vs. 0.55±0.71%; p=0.171), despite the fact that levels were similar at study start (8.41±0.60 vs. 8.47±0.45; p=0.831) and at the end of the On period (7.24±0.48 vs. 7.38±0.61; p=0.566). Frequency of CGM use in patients who continued SAP therapy was high (61.2% of the time in the last 3 months). Our study suggests that the additional benefit of SAP therapy achieved in a clinical trial may persist in the long term in routine clinical care of patients with T1DM. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  11. Systemic and regional hemodynamic effects of enalaprilat infusion in experimental normotensive sepsis

    Directory of Open Access Journals (Sweden)

    L. Rahal

    Full Text Available Angiotensin-converting enzyme inhibitors have been shown to improve splanchnic perfusion in distinct shock states. We hypothesized that enalaprilat potentiates the benefits of early fluid resuscitation in severe experimental sepsis, particularly in the splanchnic region. Anesthetized and mechanically ventilated mongrel dogs received an intravenous infusion of live Escherichia coli over a period of 30 min. Thereafter, two interventions were performed: fluid infusion (normal saline, 32 mL/kg over 30 min and enalaprilat infusion (0.02 mg kg-1 min-1 for 60 min in randomized groups. The following groups were studied: controls (fluid infusion, N = 4, E1 (enalaprilat infusion followed by fluid infusion, N = 5 and E2 (fluid infusion followed by enalaprilat infusion, N = 5. All animals were observed for a 120 min after bacterial infusion. Mean arterial pressure, cardiac output (CO, portal vein blood flow (PVBF, systemic and regional oxygen-derived variables, and lactate levels were measured. Rapid and progressive reductions in CO and PVBF were induced by the infusion of live bacteria, while minor changes were observed in mean arterial pressure. Systemic and regional territories showed a significant increase in oxygen extraction and lactate levels. Widening venous-arterial and portal-arterial pCO2 gradients were also detected. Fluid replacement promoted transient benefits in CO and PVBF. Enalaprilat after fluid resuscitation did not affect systemic or regional hemodynamic variables. We conclude that in this model of normotensive sepsis inhibition of angiotensin-converting enzyme did not interfere with the course of systemic or regional hemodynamic and oxygen-derived variables.

  12. Glucose pump test can be used to measure blood flow rate of native arteriovenous fistula in chronic hemodialysis.

    Science.gov (United States)

    Yavuz, Y C; Selcuk, N Y; Altıntepe, L; Güney, I; Yavuz, S

    2018-01-01

    In chronic hemodialysis patients, the low flow of vascular access may leads to inadequate dialysis, increased rate of hospitalization, morbidity, and mortality. It was found that surveillance should be performed for native arteriovenous (AV) should not be performed for AV graft in various studies. However, surveillance was done in graft AV fistulas in most studies. Doppler ultrasonography (US) was suggested for surveillance of AV fistulas by the last vascular access guideline of National Kidney Foundation Disease Outcomes Quality Initiative (NKF KDOQI). The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by pump and was measured at basal before the infusion and 11 s after the start of the infusion by glucometer. Doppler US was done by an expert radiologist. Used statistical tests were Mann-Whitney U test, Friedman test, regression analysis, and multiple regression analysis. Median values of blood flow rates measured by GPT (707 mL/min) and by Doppler US (700 mL/min) were not different (Z = 0.414, P = 0.678). Results of GPT and Doppler US measurements were positive correlate by regression analysis. The mean GPT value of diabetic patients (n = 39; 908 mL/min) was similar to that of nondiabetic patients (n = 54; 751 mL/min; Z = 1.31, P = 0.188). GPT values measured at three different dialysis session did not differ from each other that by Friedman test (F = 0.92, P = 0.39). This showed that GPT was stable and reliable. Glucose pump test can be used to measure blood flow rate of native AV fistula. GPT is an accurate and reliable test.

  13. Central infusion of leptin improves insulin resistance and suppresses beta-cell function, but not beta-cell mass, primarily through the sympathetic nervous system in a type 2 diabetic rat model.

    Science.gov (United States)

    Park, Sunmin; Ahn, Il Sung; Kim, Da Sol

    2010-06-05

    We investigated whether hypothalamic leptin alters beta-cell function and mass directly via the sympathetic nervous system (SNS) or indirectly as the result of altered insulin resistant states. The 90% pancreatectomized male Sprague Dawley rats had sympathectomy into the pancreas by applying phenol into the descending aorta (SNSX) or its sham operation (Sham). Each group was divided into two sections, receiving either leptin at 300ng/kgbw/h or artificial cerebrospinal fluid (aCSF) via intracerebroventricular (ICV) infusion for 3h as a short-term study. After finishing the infusion study, ICV leptin (3mug/kg bw/day) or ICV aCSF (control) was infused in rats fed 30 energy % fat diets by osmotic pump for 4weeks. At the end of the long-term study, glucose-stimulated insulin secretion and islet morphometry were analyzed. Acute ICV leptin administration in Sham rats, but not in SNSX rats, suppressed the first- and second-phase insulin secretion at hyperglycemic clamp by about 48% compared to the control. Regardless of SNSX, the 4-week administration of ICV leptin improved glucose tolerance during oral glucose tolerance tests and insulin sensitivity at hyperglycemic clamp, compared to the control, while it suppressed second-phase insulin secretion in Sham rats but not in SNSX rats. However, the pancreatic beta-cell area and mass were not affected by leptin and SNSX, though ICV leptin decreased individual beta-cell size and concomitantly increased beta-cell apoptosis in Sham rats. Leptin directly decreases insulin secretion capacity mainly through the activation of SNS without modulating pancreatic beta-cell mass.

  14. Clinical evaluation of the use of a multifunctional remotely controlled insulin pump: multicenter observational study.

    Science.gov (United States)

    Boizel, Robert; Pinget, Michel; Lachgar, Karim; Parkin, Christopher G; Grulet, Hervé; Guillon-Metz, Françoise; Weissmann, Joerg

    2014-11-01

    Current insulin pumps now feature advanced functions for calculating insulin dosages, delivering insulin and analyzing data, however, the perceived usefulness of these functions in clinical settings has not been well studied. We assessed the use and patient perceptions of an insulin delivery system (Accu-Chek® Combo, Roche Diagnostics, Mannheim, Germany) that combines an insulin pump and a handheld multifunctional blood glucose meter with integrated remote control functions. This prospective, observational, multicenter study enrolled 74 type 1 diabetes patients within 13 weeks after starting use of the pump system. At 4 to 24 weeks, investigators collected usage data from the latest 14-day period. Seventy-two patients completed the evaluation, aged 39 ± 15 years, diabetes duration 16 ± 13 years, HbA1c 8.3 ± 1.6%. At follow-up, 62 (86.1%) patients used the remote control for ≥50% of all boluses, 20 (27.8%) used the bolus advisor for ≥50% of all boluses, and 42 (58.3%) viewed at least 1 of the e-logbook reports. More than 95% of users appraised the functions as easy-to-use and useful; median scores from VAS (0 = useless to 100 = indispensable) ranged from 72 to 85. A high percentage of study patients used the system's advanced features, especially the remote control feature for bolusing. Overall, patients assessed the functions as useful and easy to use. Results support the implementation of these smart capabilities in further insulin pump developments. © 2014 Diabetes Technology Society.

  15. Pumps and pump facilities. 2. ed.

    International Nuclear Information System (INIS)

    Bohl, W.; Bauerfeind, H.; Gutmann, G.; Leuschner, G.; Matthias, H.B.; Mengele, R.; Neumaier, R.; Vetter, G.; Wagner, W.

    1981-01-01

    This book deals with the common fundamental aspects of liquid pumps and gives an exemplary choice of the most important kinds of pumps. The scientific matter is dealt with by means of practical mathematical examples among other ways of presenting the matter. Survey of contents: Division on main operational data of pumps - pipe characteristics - pump characteristics - suction behaviour of the pumps - projecting and operation of rotary pumps - boiler feed pumps - reactor feed pumps - oscillating positive-displacement pumps - eccentric spiral pumps. (orig./GL) [de

  16. Pumps for medium sized solar systems

    DEFF Research Database (Denmark)

    Furbo, Simon

    1996-01-01

    The suitability of the electronically controlled circulation pump type UPE 2000 from Grundfos for large solar heating systems was elucidated.......The suitability of the electronically controlled circulation pump type UPE 2000 from Grundfos for large solar heating systems was elucidated....

  17. New and future heat pump technologies

    Science.gov (United States)

    Creswick, F. A.

    It is not possible to say for sure what future heat pumps will look like, but there are some interesting possibilities. In the next five years, we are likely to see US heat pumps with two kinds of innovations: capacity modulation and charge control. Capacity modulation will be accomplished by variable-speed compressor motors. The objective of charge control is to keep the refrigerant charge in the system where it belongs for best performance; there are probably many ways to accomplish this. Charge control will improve efficiency and durability; capacity modulation will further improve efficiency and comfort. The Stirling cycle heat pump has several interesting advantages, but it is farther out in time. At present, we don't know how to make it as efficient as the conventional vapor-compression heat pump. Electric utility people should be aware that major advances are being made in gas-fired heat pumps which could provide strong competition in the future. However, even a gas-fired heat pump has a substantial auxiliary electric power requirement. The resources needed to develop advanced heat pumps are substantial and foreign competition will be intense. It will be important for utilities, manufacturers, and the federal government to work in close cooperation.

  18. Comparison the effect of two ways of tube feeding including bolus and continuous infusion on gastric residual volume and diarrhea in patients hospitalized in Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Shahriari M

    2015-05-01

    Full Text Available Background and Objective: Proper nutritional support is one of the important caring aspects in patients who were hospitalized in Intensive Care Unit. Although the several studies have been done concerning the selection of proper nutrition method for patients, but there is no agreement on this issue. The aim of current study was the compare the effect of two ways of tube feeding including bolus and continuous infusion on gastric residual volume and diarrhea in patients hospitalized in Intensive Care Unit.  Materials and Method: The current clinical trial was conducted on patients who were hospitalized in intensive care unit in Alzahra hospital in Isfahan, 2013. Fifty patients were selected through convenient sampling and were randomly assigned into two groups of 25 people of intervention and control. Nutrition was done through infusion pump in intervention group and by bolus in control group. Gastric residual volume and diarrhea was assessed each four hours for four days. Data were gathered through checklist and were analyzed by SPSS18 using descriptive and inferential statistics including independent T-test, Fisher's exact test and repeated measures ANOVA.  Results: The results showed that the mean of gastric residual volume in control group was more than the intervention group on the third day (p=0.04. Also, the mean of gastric residual volume did not show significant difference at different times in intervention group, but the mean of gastric residual volume was significantly increased in control group at different times (p=0.04. Fisher's exact test showed no significant difference between two groups concerning the diarrhea frequency.  Conclusion: In nutritional support with continuous infusion method, gastric residual volume was not increased and gastric emptying rate was not diminished. Therefore, this method can be used as an appropriate nutritional support in intensive care unit.

  19. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid ''P''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Report (ATR) provides the test results for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''P''. The ATR summaries the results and provides a copy of the ATP and inspections in the Appendix

  20. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid Q

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Report (ATR) provides the test results for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''Q''. The ATR summaries the results and provides a copy of the ATP and inspections in the Appendix

  1. METHOD FOR OPTIMIZING THE ENERGY OF PUMPS

    NARCIS (Netherlands)

    Skovmose Kallesøe, Carsten; De Persis, Claudio

    2013-01-01

    The device for energy-optimization on operation of several centrifugal pumps controlled in rotational speed, in a hydraulic installation, begins firstly with determining which pumps as pilot pumps are assigned directly to a consumer and which pumps are hydraulically connected in series upstream of

  2. Considerations for reference pump curves

    International Nuclear Information System (INIS)

    Stockton, N.B.

    1992-01-01

    This paper examines problems associated with inservice testing (IST) of pumps to assess their hydraulic performance using reference pump curves to establish acceptance criteria. Safety-related pumps at nuclear power plants are tested under the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (the Code), Section 11. The Code requires testing pumps at specific reference points of differential pressure or flow rate that can be readily duplicated during subsequent tests. There are many cases where test conditions cannot be duplicated. For some pumps, such as service water or component cooling pumps, the flow rate at any time depends on plant conditions and the arrangement of multiple independent and constantly changing loads. System conditions cannot be controlled to duplicate a specific reference value. In these cases, utilities frequently request to use pump curves for comparison of test data for acceptance. There is no prescribed method for developing a pump reference curve. The methods vary and may yield substantially different results. Some results are conservative when compared to the Code requirements; some are not. The errors associated with different curve testing techniques should be understood and controlled within reasonable bounds. Manufacturer's pump curves, in general, are not sufficiently accurate to use as reference pump curves for IST. Testing using reference curves generated with polynomial least squares fits over limited ranges of pump operation, cubic spline interpolation, or cubic spline least squares fits can provide a measure of pump hydraulic performance that is at least as accurate as the Code required method. Regardless of the test method, error can be reduced by using more accurate instruments, by correcting for systematic errors, by increasing the number of data points, and by taking repetitive measurements at each data point

  3. The effect of ethanol infusion on the size of the ablated lesion in radiofrequency thermal ablation: A pilot study

    International Nuclear Information System (INIS)

    Kim, Young Sun; Rhim, Hyun Chul; Koh, Byung Hee; Cho, On Koo; Seo, Heung Suk; Kim, Yong Soo; Joo, Kyoung Bin

    2001-01-01

    To assess the effect of ethanol infusion on the size of ablated lesion during radiofrequency (RF) thermal ablation. We performed an ex vivo experimental study using a total of 15 pig livers. Three groups were designed: 1)normal control (n=10), 2) saline infusion (n=10) 3) ethanol infusion (n=10). Two radiofrequency ablations were done using a 50 watt RF generator and a 15 guage expandable elections with four prongs in each liver. During ablation for 8 minutes, continuous infusion of fluid at a rate of 0.5 ml/min through the side arm of electrode was performed. We checked the frequency of the 'impeded-out' phenomenon due to abrupt increase of impedance during ablation. Size of ablated lesion was measured according to length, width, height, and subsequently volume after the ablations. The sizes of the ablated lesions were compared between the three groups. 'Impeded-out' phenomenon during ablation was noted 4 times in control group, although that never happened in saline or ethanol infusion groups. There were significant differences in the volumes of ablated lesions between control group (10.62 ± 1.45 cm 3 ) and saline infusion group (15.33 ± 2.47 cm 3 ), and saline infusion group and ethanol infusion group (18.78 ± 3.58 cm 3 ) (p<0.05). Fluid infusion during radiofrequency thermal ablation decrease a chance of charming and increase the volume of the ablated lesion. Ethanol infusion during ablation may induce larger volume of ablated lesion than saline infusion.

  4. Study protocol. ECSSIT - Elective Caesarean Section Syntocinon Infusion Trial. A multi-centre randomised controlled trial of oxytocin (Syntocinon) 5 IU bolus and placebo infusion versus oxytocin 5 IU bolus and 40 IU infusion for the control of blood loss at elective caesarean section.

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2012-02-01

    BACKGROUND: Caesarean section is one of the most commonly performed major operations in women throughout the world. Rates are escalating, with studies from the United States of America, the United Kingdom, China and the Republic of Ireland reporting rates between 20% and 25%. Operative morbidity includes haemorrhage, anaemia, blood transfusion and in severe cases, maternal death. The value of routine oxytocics in the third stage of vaginal birth has been well established and it has been assumed that these benefits apply to caesarean delivery as well. A slow bolus dose of oxytocin is recommended following delivery of the baby at caesarean section. Some clinicians use an additional infusion of oxytocin for a further period following the procedure. Intravenous oxytocin has a very short half-life (4-10 minutes) therefore the potential advantage of an oxytocin infusion is that it maintains uterine contractility throughout the surgical procedure and immediate postpartum period, when most primary haemorrhages occur. The few trials to date addressing the optimal approach to preventing haemorrhage at caesarean section have been under-powered to evaluate clinically important outcomes. There has been no trial to date comparing the use of an intravenous slow bolus of oxytocin versus an oxytocin bolus and infusion. METHODS AND DESIGN: A multi-centre randomised controlled trial is proposed. The study will take place in five large maternity units in Ireland with collaboration between academics and clinicians in the disciplines of obstetrics and anaesthetics. It will involve 2000 women undergoing elective caesarean section after 36 weeks gestation. The main outcome measure will be major haemorrhage (blood loss >1000 ml). A study involving 2000 women will have 80% power to detect a 36% relative change in the risk of major haemorrhage with two-sided 5% alpha. DISCUSSION: It is both important and timely that we evaluate the optimal approach to the management of the third stage at

  5. Study protocol. ECSSIT - Elective Caesarean Section Syntocinon Infusion Trial. A multi-centre randomised controlled trial of oxytocin (Syntocinon) 5 IU bolus and placebo infusion versus oxytocin 5 IU bolus and 40 IU infusion for the control of blood loss at elective caesarean section.

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2009-01-01

    BACKGROUND: Caesarean section is one of the most commonly performed major operations in women throughout the world. Rates are escalating, with studies from the United States of America, the United Kingdom, China and the Republic of Ireland reporting rates between 20% and 25%. Operative morbidity includes haemorrhage, anaemia, blood transfusion and in severe cases, maternal death. The value of routine oxytocics in the third stage of vaginal birth has been well established and it has been assumed that these benefits apply to caesarean delivery as well. A slow bolus dose of oxytocin is recommended following delivery of the baby at caesarean section. Some clinicians use an additional infusion of oxytocin for a further period following the procedure. Intravenous oxytocin has a very short half-life (4-10 minutes) therefore the potential advantage of an oxytocin infusion is that it maintains uterine contractility throughout the surgical procedure and immediate postpartum period, when most primary haemorrhages occur. The few trials to date addressing the optimal approach to preventing haemorrhage at caesarean section have been under-powered to evaluate clinically important outcomes. There has been no trial to date comparing the use of an intravenous slow bolus of oxytocin versus an oxytocin bolus and infusion. METHODS AND DESIGN: A multi-centre randomised controlled trial is proposed. The study will take place in five large maternity units in Ireland with collaboration between academics and clinicians in the disciplines of obstetrics and anaesthetics. It will involve 2000 women undergoing elective caesarean section after 36 weeks gestation. The main outcome measure will be major haemorrhage (blood loss >1000 ml). A study involving 2000 women will have 80% power to detect a 36% relative change in the risk of major haemorrhage with two-sided 5% alpha. DISCUSSION: It is both important and timely that we evaluate the optimal approach to the management of the third stage at

  6. Bubble formation occurs in insulin pumps in response to changes in ambient temperature and atmospheric pressure but not as a result of vibration.

    Science.gov (United States)

    Lopez, Prudence E; King, Bruce R; Goss, Peter W; Chockalingam, Ganesh

    2014-01-01

    Bubble formation in insulin pump giving sets is a common problem. We studied change in temperature, change in atmospheric pressure, and vibration as potential mechanisms of bubble formation. 5 Animas 2020 pumps with 2 mL cartridges and Inset II infusion systems, 5 Medtronic Paradigm pumps with 1.8 mL cartridge and Quickset and 3 Roche Accu-chek pumps with 3.15 mL cartridges were used. Temperature study: insulin pumps were exposed to a temperature change from 4°C to 37°C. Pressure study: insulin pumps were taken to an altitude of 300 m. Vibration study: insulin pumps were vigorously shaken. All were observed for bubble formation. Bubble formation was observed with changes in temperature and atmospheric pressure. Bubble formation did not occur with vibration. Changes in insulin temperature and atmospheric pressure are common and may result in bubble formation. Vibration may distribute bubbles but does not cause bubble formation.

  7. Using Smart Pumps to Understand and Evaluate Clinician Practice Patterns to Ensure Patient Safety

    Science.gov (United States)

    Mansfield, Jennifer; Jarrett, Steven

    2013-01-01

    Background: Safety software installed on intravenous (IV) infusion pumps has been shown to positively impact the quality of patient care through avoidance of medication errors. The data derived from the use of smart pumps are often overlooked, although these data provide helpful insight into the delivery of quality patient care. Objective: The objectives of this report are to describe the value of implementing IV infusion safety software and analyzing the data and reports generated by this system. Case study: Based on experience at the Carolinas HealthCare System (CHS), executive score cards provide an aggregate view of compliance rate, number of alerts, overrides, and edits. The report of serious errors averted (ie, critical catches) supplies the location, date, and time of the critical catch, thereby enabling management to pinpoint the end-user for educational purposes. By examining the number of critical catches, a return on investment may be calculated. Assuming 3,328 of these events each year, an estimated cost avoidance would be $29,120,000 per year for CHS. Other reports allow benchmarking between institutions. Conclusion: A review of the data about medication safety across CHS has helped garner support for a medication safety officer position with the goal of ultimately creating a safer environment for the patient. PMID:24474836

  8. Animal model of rapid crystalloid infusion in rats

    Directory of Open Access Journals (Sweden)

    Flavio Stillitano Orgaes

    2013-04-01

    Full Text Available PURPOSE: To describe an animal model of rapid intravenous infusion with different volumes of crystalloid and discuss the clinical findings. METHODS: Fifty six male Wistar rats were used, divided randomly in seven groups (n = 8. The rats of groups 1 to 6 received lactated Ringer´s solution intravenously, in the rate of 25 ml/min, with different volumes proportional to blood volume (BV. The rats of group 0 were submitted to the same procedure, but did not receive the fluid (control group. The data included respiratory rate, heart rate, saturation of peripheral oxygen (SpO2 in two times (before and after the infusion, and upshots (respiratory arrest and death. Dunnett´s test and ANOVA were used. RESULTS: The clinical signs significantly changed in the 2, 2.5 and 3 fold BV groups. The respiratory arrest was observed in the 1.5, 2, 2.5 and 3 fold BV groups, but death was present only in 2.5 and 3 fold BV groups. CONCLUSIONS: The infusion of crystalloid in the same volume of blood volume did not cause significant variation in respiratory and heart rate, saturation of peripheral oxygen and did not induce respiratory arrest. The infusion of a volume of 3 fold blood volume was lethal to all animals.

  9. Efficacy and safety of an insulin infusion protocol in a surgical ICU.

    Science.gov (United States)

    Taylor, Beth E; Schallom, Marilyn E; Sona, Carrie S; Buchman, Timothy G; Boyle, Walter A; Mazuski, John E; Schuerer, Douglas E; Thomas, James M; Kaiser, Christy; Huey, Way Y; Ward, Myrna R; Zack, Jeanne E; Coopersmith, Craig M

    2006-01-01

    Hyperglycemia is associated with complications in the surgical intensive care unit. The purpose of this study was to determine the efficacy and safety of nurse-driven insulin infusion protocols in lowering blood glucose (BG) in critical illness. All patients in a 24-bed surgical intensive care unit who required i.v. insulin infusions during 3 noncontiguous 6-month periods from 2002 to 2004 were evaluated. In the preintervention phase, 71 patients received a physician-initiated insulin infusion without a developed protocol. They were compared with 95 patients who received a nurse-driven insulin infusion protocol with a target BG of 120 to 150 mg/dL and to 119 patients who received a more stringent protocol with a target BG of 80 to 110 mg/dL. There was a stepwise decrease in average daily BG levels, from 190 to 163 to 132 mg/dL (p < 0.001). The less stringent protocol decreased the time to achieve a BG level < 150 mg/dL from 14.1 to 7.4 hours compared with physician-driven management (p < 0.05) resulting in similar time on an insulin infusion (53 versus 48 hours). The more intensive protocol brought BG levels < 150 mg/dL in 7.2 hours and < 111 mg/dL in 13.6 hours, but increased the length of time a patient was on an insulin infusion to 77 hours. The incidence of severe hypoglycemia (BG < 40 mg/dL) was statistically similar between the groups, ranging between 1.1% and 3.4%. Implementation of a nurse-driven protocol led to more rapid and more effective BG control in critically ill surgical patients compared with physician management. Tighter BG control can be obtained without a significant increase in hypoglycemia, although this is associated with increased time on an insulin infusion.

  10. Optimal intravenous infusion to decrease the haematocrit level in patient of DHF infection

    Science.gov (United States)

    Handayani, D.; Nuraini, N.; Saragih, R.; Wijaya, K. P.; Naiborhu, J.

    2014-02-01

    The optimal control of infusion model for Dengue Hemorrhagic Fever (DHF) infection is formulated here. The infusion model will be presented in form of haematocrit level. The input control aim to normalize the haematocrit level and is expressed as infusion volume on mL/day. The stability near the equilibrium points will be analyzed. Numerical simulation shows the dynamic of each infection compartments which gives a description of within-host dynamic of dengue virus. These results show particularly that infected compartments tend to be vanished in ±15days after the onset of the virus. In fact, without any control added, the haematocrit level will decrease but not up to the normal level. Therefore the effective haematocrit normalization should be done with the treatment control. Control treatment for a fixed time using a control input can bring haematocrit level to normal range 42-47%. The optimal control in this paper is divided into three cases, i.e. fixed end point, constrained input, and tracking haematocrit state. Each case shows different infection condition in human body. However, all cases require that the haematocrit level to be in normal range in fixed final time.

  11. Control de bacteriemia nosocomial pediátrica mediante un programa de cultivo de soluciones parenterales en uso Pediatric nosocomial bacteremia control program based on culturing in use parenteral infusions

    Directory of Open Access Journals (Sweden)

    Juan M. Muñoz

    1999-01-01

    Full Text Available OBJETIVO. Dado que Klebsiella, Enterobacter y Serratia se multiplican en soluciones parenterales y son responsables de una elevada proporción de bacteriemias en los hospitales de México, se propone una estrategia de control mediante la vigilancia microbiológica de las soluciones en uso. MATERIAL Y MÉTODOS. Hospital de enseñanza de segundo nivel con 193 camas. Atiende principalmente pacientes de escasos recursos. En 1992 se inició la vigilancia de la esterilidad de las soluciones parenterales en los servicios pediátricos mediante cuatro estrategias: durante la primera etapa se cultivó el total de soluciones en uso. Durante la segunda se cultivaron muestras aleatoriamente elegidas. Tercera y cuarta etapas con muestreo controlado y dirigido, respectivamente. RESULTADOS. Se han cultivado 1940 infusiones. Se ha observado una reducción de la tasa de contaminación (de 29.6% en 1992 a 12.9% en 1997, pOBJECTIVES. As Klebsiella, Enterobacter and Serratia are capable of growth in IV fluids and these bacteria are commonly implicated in nosocomial bacteremia, a control strategy through microbiological surveilance of in-use parenteral solutions is proposed. MATERIAL AND METHODS. A second level general teaching hospital, serving low-income patients. Through four consecutive strategies, a continous surveillance program of IV fluids sterility in pediatric wards was stablished in 1992. During the first stage all of the in -use solutions were cultured. During the second stage randomly selected samples were studied. Third stage was designed as a case-control study. The last stage included samples drawn in convenience. Positive cultures point out eventual infusion mishandling, as well as high-risk areas and patients. RESULTS. After culturing 1940 parenteral solutions, infusion contamination rates decreased from 29.6% in 1992 to 12.9% in 1997 (p< 0.001. The proportion of Gram-negative rods isolated from blood cultures went from 72.7% to 40.85% (p< 0

  12. Lunar Base Heat Pump

    Science.gov (United States)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  13. Modeling and dynamic control simulation of unitary gas engine heat pump

    International Nuclear Information System (INIS)

    Zhao Yang; Haibo Zhao; Zheng Fang

    2007-01-01

    Based on the dynamic model of the gas engine heat pump (GEHP) system, an intelligent control simulation is presented to research the dynamic characteristics of the system in the heating operation. The GEHP system simulation model consists of eight models for its components including a natural gas engine, a compressor, a condenser, an expansion valve, an evaporator, a cylinder jacket heat exchanger, an exhaust gas heat exchanger and an auxiliary heater. The intelligent control model is composed of the prediction controller model and the combined controller model. The Runge-Kutta Fehlberg fourth-fifth order algorithms are used to solve the differential equations. The results show that the model is very effective in analyzing the effects of the control system, and the steady state accuracy of the intelligent control scheme is higher than that of the fuzzy controller

  14. Groundwater-pumping optimization for land-subsidence control in Beijing plain, China

    Science.gov (United States)

    Qin, Huanhuan; Andrews, Charles B.; Tian, Fang; Cao, Guoliang; Luo, Yong; Liu, Jiurong; Zheng, Chunmiao

    2018-01-01

    Beijing, in the North China plain, is one of the few megacities that uses groundwater as its main source of water supply. Groundwater accounts for about two-thirds of the city's water supply, and during the past 50 years the storage depletion from the unconsolidated aquifers underlying the city has been >10.4 billion m3. By 2010, groundwater pumping in the city had resulted in a cumulative subsidence of greater than 100 mm in an area of about 3,900 km2, with a maximum cumulative subsidence of >1,200 mm. This subsidence has caused significant social and economic losses in Beijing, including significant damage to underground utilities. This study was undertaken to evaluate various future pumping scenarios to assist in selecting an optimal pumping scenario to minimize overall subsidence, meet the requirements of the Beijing Land Subsidence Prevention Plan (BLSPP 2013-2020), and be consistent with continued sustainable economic development. A numerical groundwater and land-subsidence model was developed for the aquifer system of the Beijing plain to evaluate land subsidence rates under the possible future pumping scenarios. The optimal pumping scenario consistent with the evaluation constraints is a reduction in groundwater pumping from three major pumping centers by 100, 50 and 20%, respectively, while maintaining an annual pumping rate of 1.9 billion m3. This scenario's land-subsidence rates satisfy the BLSPP 2013-2020 and the pumping scenario is consistent with continued economic development. It is recommended that this pumping scenario be adopted for future land-subsidence management in Beijing.

  15. Groundwater-pumping optimization for land-subsidence control in Beijing plain, China

    Science.gov (United States)

    Qin, Huanhuan; Andrews, Charles B.; Tian, Fang; Cao, Guoliang; Luo, Yong; Liu, Jiurong; Zheng, Chunmiao

    2018-06-01

    Beijing, in the North China plain, is one of the few megacities that uses groundwater as its main source of water supply. Groundwater accounts for about two-thirds of the city's water supply, and during the past 50 years the storage depletion from the unconsolidated aquifers underlying the city has been >10.4 billion m3. By 2010, groundwater pumping in the city had resulted in a cumulative subsidence of greater than 100 mm in an area of about 3,900 km2, with a maximum cumulative subsidence of >1,200 mm. This subsidence has caused significant social and economic losses in Beijing, including significant damage to underground utilities. This study was undertaken to evaluate various future pumping scenarios to assist in selecting an optimal pumping scenario to minimize overall subsidence, meet the requirements of the Beijing Land Subsidence Prevention Plan (BLSPP 2013-2020), and be consistent with continued sustainable economic development. A numerical groundwater and land-subsidence model was developed for the aquifer system of the Beijing plain to evaluate land subsidence rates under the possible future pumping scenarios. The optimal pumping scenario consistent with the evaluation constraints is a reduction in groundwater pumping from three major pumping centers by 100, 50 and 20%, respectively, while maintaining an annual pumping rate of 1.9 billion m3. This scenario's land-subsidence rates satisfy the BLSPP 2013-2020 and the pumping scenario is consistent with continued economic development. It is recommended that this pumping scenario be adopted for future land-subsidence management in Beijing.

  16. Equipment for a 'non-stop' water infusion system

    Energy Technology Data Exchange (ETDEWEB)

    Deprez, J C

    1978-01-01

    This paper gives a definition of the non-stop infusion system (technique employed during the winning operation to prevent the emission of coal-dust). The system works at low-output and reduced pressure level; delivery and control is continuous. Explains the principles behind the MECANELEC flow regulator and the SCHLUMBERGER device to monitor correct operation. Describes a SCHLUMBERGER unit used in the Houilleres de Blanzy as well as a combined MECANELEC-SCHLUMBERGER installation in service at HBNPC. This combination allows water infusion to be carried out as required by the conditions. Possibility of introducing necessary improvements (such as a device to prevent leakage) is discussed.

  17. Infusion dose requirement of rocuronium in patients on phenytoin therapy - A prospective comparative study.

    Science.gov (United States)

    Sheshadri, Veena; Radhakrishnan, Arathi; Halemani, Kusuma; Keshavan, Venkatesh H

    2017-10-01

    Patients with intracranial tumour are usually on anticonvulsants. Patients on phenytoin therapy demonstrate rapid metabolism of nondepolarising muscle relaxants secondary to enzyme induction. Infusion dose requirement of rocuronium in such patients has been sparingly studied. We studied the continuous infusion dose requirement of rocuronium bromide in patients on phenytoin therapy and its correlation with serum levels of phenytoin. Seventy-five patients scheduled for supratentorial tumour surgery were included in the study. Patients not on phenytoin were taken as control. The primary outcome variable studied was the infusion dose requirement of rocuronium in patients on phenytoin. Based on pre-operative serum phenytoin levels, study group patients were divided into two groups: sub-therapeutic level group (phenytoin level 10 μg/mL). Following anaesthesia induction, rocuronium bromide 0.6 mg/kg was administered to achieve tracheal intubation. Rocuronium infusion was titrated to maintain zero response on the train-of-four response. Demographic data were comparable. Patients receiving phenytoin required higher infusion dose compared to the control group (0.429 ± 0.2 mg/kg/h vs. 0.265 ± 0.15 mg/kg/h, P rocuronium (0.429 ± 0.205 mg/kg/h vs. 0.429 ± 0.265 mg/kg/h ( P = 0.815). The recovery was faster in the phenytoin group compared to the control group. Haowever, it was not clinically significant. The infusion dose requirement of rocuronium bromide in patients on phenytoin is higher and the serum levels of phenytoin does not influence the dose required.

  18. Condensate and feedwater systems, pumps, and water chemistry. Volume seven

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Subject matter includes condensate and feedwater systems (general features of condensate and feedwater systems, condenser hotwell level control, condensate flow, feedwater flow), pumps (principles of fluid flow, types of pumps, centrifugal pumps, positive displacement pumps, jet pumps, pump operating characteristics) and water chemistry (water chemistry fundamentals, corrosion, scaling, radiochemistry, water chemistry control processes, water pretreatment, PWR water chemistry, BWR water chemistry, condenser circulating water chemistry

  19. Self-optimizing control of air-source heat pump with multivariable extremum seeking

    International Nuclear Information System (INIS)

    Dong, Liujia; Li, Yaoyu; Mu, Baojie; Xiao, Yan

    2015-01-01

    The air-source heat pump (ASHP) is widely adopted for cooling and heating of residential and commercial buildings. The performance of ASHP can be controlled by several operating variables, such as compressor capacity, condenser fan speed, evaporator fan speed and suction superheat. In practice, the system characteristics can be varied significantly by the variations in ambient condition, operation setpoint, internal thermal load and equipment degradation, which makes it difficult to obtain accurate plant models. As consequence, the model based control strategies for ASHP could limit the achievable energy efficiency. Model-free self-optimizing control strategies are thus more preferable. In this study, a multi-input extremum seeking control (ESC) scheme is proposed for both heating and cooling operation of ASHP. The zone temperature is assumed to be regulated by the compressor capacity, while the expansion valve opening is used to regulate the suction superheat at the given setpoint. The total power consumption of the compressor, the condenser fan and the evaporator fan is measured as input to the ESC, while the ESC controls the evaporator fan speed, the condenser fan speed and the suction superheat setpoint. The proposed scheme is evaluated with a Modelica based dynamic simulation model of ASHP under both cooling and heating modes of operation. Simulation results show the effectiveness of the proposed scheme to achieve the maximum achievable efficiency in a nearly model-free manner. - Highlights: • Multi-input ESC. • Air-source heat pump. • Cooling and heating. • Modelica based model

  20. Thermomechanical piston pump development

    Science.gov (United States)

    Sabelman, E. E.

    1971-01-01

    A thermally powered reciprocating pump has been devised to replace or augment an electric pump for the transport of temperature-control fluid on the Thermoelectric Outer Planet Spacecraft (TOPS). The thermally powered pump operates cyclically by extracting heat energy from the fluid by means of a vapor-pressure expansion system and by using the heat to perform the mechanical work of pumping. A feasibility test unit has been constructed to provide an output of 7 cu in during a 10- to 100-second cycle. It operates with a fluid input temperature of 200 to 300 F and a heat sink temperature of 0 to 30 F.

  1. A prototype of volume-controlled tidal liquid ventilator using independent piston pumps.

    Science.gov (United States)

    Robert, Raymond; Micheau, Philippe; Cyr, Stéphane; Lesur, Olivier; Praud, Jean-Paul; Walti, Hervé

    2006-01-01

    Liquid ventilation using perfluorochemicals (PFC) offers clear theoretical advantages over gas ventilation, such as decreased lung damage, recruitment of collapsed lung regions, and lavage of inflammatory debris. We present a total liquid ventilator designed to ventilate patients with completely filled lungs with a tidal volume of PFC liquid. The two independent piston pumps are volume controlled and pressure limited. Measurable pumping errors are corrected by a programmed supervisor module, which modifies the inserted or withdrawn volume. Pump independence also allows easy functional residual capacity modifications during ventilation. The bubble gas exchanger is divided into two sections such that the PFC exiting the lungs is not in contact with the PFC entering the lungs. The heating system is incorporated into the metallic base of the gas exchanger, and a heat-sink-type condenser is placed on top of the exchanger to retrieve PFC vapors. The prototype was tested on 5 healthy term newborn lambs (<5 days old). The results demonstrate the efficiency and safety of the prototype in maintaining adequate gas exchange, normal acido-basis equilibrium, and cardiovascular stability during a short, 2-hour total liquid ventilator. Airway pressure, lung volume, and ventilation scheme were maintained in the targeted range.

  2. A Novel Algorithm (G-JPSO and Its Development for the Optimal Control of Pumps in Water Distribution Networks

    Directory of Open Access Journals (Sweden)

    Rasoul Rajabpour

    2017-01-01

    Full Text Available Recent decades have witnessed growing applications of metaheuristic techniques as efficient tools for solving complex engineering problems. One such method is the JPSO algorithm. In this study, innovative modifications were made in the nature of the jump algorithm JPSO to make it capable of coping with graph-based solutions, which led to the development of a new algorithm called ‘G-JPSO’. The new algorithm was then used to solve the Fletcher-Powell optimal control problem and its application to optimal control of pumps in water distribution networks was evaluated. Optimal control of pumps consists in an optimum operation timetable (on and off for each of the pumps at the desired time interval. Maximum number of on and off positions for each pump was introduced into the objective function as a constraint such that not only would power consumption at each node be reduced but such problem requirements as the minimum pressure required at each node and minimum/maximum storage tank heights would be met. To determine the optimal operation of pumps, a model-based optimization-simulation algorithm was developed based on G-JPSO and JPSO algorithms. The model proposed by van Zyl was used to determine the optimal operation of the distribution network. Finally, the results obtained from the proposed algorithm were compared with those obtained from ant colony, genetic, and JPSO algorithms to show the robustness of the proposed algorithm in finding near-optimum solutions at reasonable computation costs.

  3. Routine sensor-augmented pump therapy in type 1 diabetes

    DEFF Research Database (Denmark)

    Nørgaard, Kirsten; Scaramuzza, Andrea; Bratina, Natasa

    2013-01-01

    Sensor-augmented pump (SAP) therapy can improve glycemic control, compared with multiple daily insulin injections or with insulin pump therapy alone, without increasing the risk of hypoglycemia.......Sensor-augmented pump (SAP) therapy can improve glycemic control, compared with multiple daily insulin injections or with insulin pump therapy alone, without increasing the risk of hypoglycemia....

  4. Influence of health locus of control and fear of hypoglycaemia on glycaemic control and treatment satisfaction in people with Type 1 diabetes on insulin pump therapy.

    Science.gov (United States)

    Indelicato, L; Mariano, V; Galasso, S; Boscari, F; Cipponeri, E; Negri, C; Frigo, A; Avogaro, A; Bonora, E; Trombetta, M; Bruttomesso, D

    2017-05-01

    To assess the influence of health locus of control and fear of hypoglycaemia on metabolic control and treatment satisfaction in people with Type 1 diabetes mellitus on continuous subcutaneous insulin infusion. People with Type 1 diabetes on continuous subcutaneous insulin infusion for at least 1 year, sub-classified as an 'acceptable glucose control' group [HbA 1c ≤ 58 mmol/mol (7.5%)] and a 'suboptimum glucose control' group [HbA 1c > 58 mmol/mol (7.5%)], were consecutively enrolled in a multicentre cross-sectional study. Questionnaires were administered to assess health locus of control [Multidimensional Health Locus of Control (MHLC) scale, with internal and external subscales], fear of hypoglycaemia [Hypoglycaemia Fear Survey II (HFS-II)] and treatment satisfaction [Diabetes Treatment Satisfaction Questionnaire (DTSQ)]. We enrolled 214 participants (mean ± sd age 43.4 ± 12.1 years). The suboptimum glucose control group (n = 127) had lower mean ± sd internal MHLC and DTSQ scores than the acceptable glucose control group (19.6 ± 5.2 vs 21.0 ± 5.0, P = 0.04 and 28.8 ± 4.8 vs 30.9 ± 4.5, P locus represents the most important locus of control pattern for achieving good metabolic control. © 2017 Diabetes UK.

  5. Comparative Study on Photovoltaic Pumping Systems Driven by Different Motors Optimized with Sliding Mode Control

    Directory of Open Access Journals (Sweden)

    Abdelhak Bouchakour

    2017-06-01

    Full Text Available This study investigates the performance of three different photovoltaic (PV water pumping systems driven by three types of motors, namely a separately excited DC motor (DCM, an asynchronous motor (ASM, and a permanent magnet synchronous motor (PMSM, via a DC/DC buck-boost converter coupled to a centrifugal pump. The purpose of this study is to implement a fast and robust control for this type of a nonlinear system, controlled by sliding mode (SM. This paper presents an SM control technique for controlling a DC/DC buck-boost converter to transfer the maximum power delivered by the PV generator. Each component is studied and analyzed to simulate the global system in MATLAB/SIMULINK. The three systems are then compared to determine the overall effectiveness of the proposed command. The study concludes that the ASM-driven PV system yields highly favorable results and requires less maintenance compared with other systems.

  6. Effects of chronic infusion of a GABAA receptor agonist or antagonist into the vestibular nuclear complex on vestibular compensation in the guinea pig.

    Science.gov (United States)

    Gliddon, Catherine M; Darlington, Cynthia L; Smith, Paul F

    2005-06-01

    The aim of this study was to determine the effects of chronic infusion of a GABA(A) receptor agonist/antagonist into the ipsilateral or contralateral vestibular nuclear complex (VNC) on vestibular compensation, the process of behavioral recovery that occurs after unilateral vestibular deafferentation (UVD). This was achieved by a mini-osmotic pump that infused, over 30 h, muscimol or gabazine into the ipsilateral or contralateral VNC. Spontaneous nystagmus (SN), yaw head tilt (YHT), and roll head tilt (RHT) were measured. Infusion of muscimol or gabazine into either the ipsilateral or the contralateral VNC had little effect on SN compensation. In contrast, infusion of muscimol (250, 500, and 750 ng) into the contralateral VNC and gabazine (31.25, 62.5, and 125 ng) into the ipsilateral VNC significantly affected YHT and RHT (p 0.05). Interestingly, the effects of muscimol and gabazine on YHT and RHT were consistent throughout the first 30 h post-UVD. Infusion of muscimol (62.5, 125, and 250 ng) into the ipsilateral VNC and gabazine (125, 375, and 750 ng) into the contralateral VNC had little effect on YHT and RHT or their rate of compensation. These results suggest that the ipsilateral gabazine and contralateral muscimol infusions are modifying the expression of the symptoms without altering the mechanism of compensation. Furthermore, the neurochemical mechanism responsible for vestibular compensation can cope with the both the GABA(A) receptor-mediated and the UVD-induced decrease in resting activity.

  7. Method for optimising the energy of pumps

    NARCIS (Netherlands)

    Skovmose Kallesøe, Carsten; De Persis, Claudio

    2011-01-01

    The method involves determining whether pumps (pu1, pu5) are directly assigned to loads (v1, v3) as pilot pumps (pu2, pu3) and hydraulically connected upstream of the pilot pumps. The upstream pumps are controlled with variable speed for energy optimization. Energy optimization circuits are selected

  8. The U.S. home infusion market.

    Science.gov (United States)

    Monk-Tutor, M R

    1998-10-01

    Medicare legislation stimulated the development of home care services but also resulted in fragmentation of service components. In the 1980s, prospective pricing and diagnosis-related groups, and resulting pressures to reduce inpatient length of stay, prompted additional growth of the industry. Even so, in 1995 home care represented only 3% of total national expenditures on health care. The annual growth rate of the home infusion industry dropped from 64% in 1982-86 to 24% in 1986-93. While revenue per patient for home infusion is expected to decrease under managed care, an increasing number of patients will support continued market growth. The home infusion market is highly competitive, with only a few large national providers and many small local providers. In 1996, 29% of acute care hospitals provided or were developing a home care program. Community pharmacists' options in the home infusion area include independent services, partnerships, joint ventures, contracts with hospitals, and franchises. The home infusion market is being integrated into alternative sites, such as ambulatory infusion centers (AICs), as providers attempt to diversify to maintain managed care contracts. AICs provide infusion therapy and nursing to noninstitutionalized, nonhome-bound patients. Untapped sources for future growth of the infusion market include long-term-care facilities. More consistent studies of the home care market are needed. Despite slowed growth in recent years, home care has a strong market in the United States.

  9. Estimation of pump operational state with model-based methods

    International Nuclear Information System (INIS)

    Ahonen, Tero; Tamminen, Jussi; Ahola, Jero; Viholainen, Juha; Aranto, Niina; Kestilae, Juha

    2010-01-01

    Pumps are widely used in industry, and they account for 20% of the industrial electricity consumption. Since the speed variation is often the most energy-efficient method to control the head and flow rate of a centrifugal pump, frequency converters are used with induction motor-driven pumps. Although a frequency converter can estimate the operational state of an induction motor without external measurements, the state of a centrifugal pump or other load machine is not typically considered. The pump is, however, usually controlled on the basis of the required flow rate or output pressure. As the pump operational state can be estimated with a general model having adjustable parameters, external flow rate or pressure measurements are not necessary to determine the pump flow rate or output pressure. Hence, external measurements could be replaced with an adjustable model for the pump that uses estimates of the motor operational state. Besides control purposes, modelling the pump operation can provide useful information for energy auditing and optimization purposes. In this paper, two model-based methods for pump operation estimation are presented. Factors affecting the accuracy of the estimation methods are analyzed. The applicability of the methods is verified by laboratory measurements and tests in two pilot installations. Test results indicate that the estimation methods can be applied to the analysis and control of pump operation. The accuracy of the methods is sufficient for auditing purposes, and the methods can inform the user if the pump is driven inefficiently.

  10. A comparison of the effects of propofol and midazolam on memory during two levels of sedation by using target-controlled infusion.

    Science.gov (United States)

    de Roode, A; van Gerven, J M; Schoemaker, R C; Engbers, F H; Olieman, W; Kroon, J R; Cohen, A F; Bovill, J G

    2000-11-01

    We examined memory during sedation with target-controlled infusions of propofol and midazolam in a double-blinded five-way, cross-over study in 10 volunteers. Each active drug infusion was targeted to sedation level 1 (asleep) and level 4 (lethargic) as determined with the Observer Assessment of Alertness/Sedation scale. At the target level of sedation, drug concentration was clamped for 30 min, during which time neutral words were presented. After 2 h, explicit memory was assessed by recall, and implicit memory by using a wordstem completion test. Venous drug concentrations (mean +/- SD) were 1350 ng/mL (+/-332 ng/mL) for propofol and 208 ng/mL (+/-112 ng/mL) for midazolam during Observer Assessment of Alertness/Sedation scale level 4; and 1620 ng/mL (+/-357 ng/mL) and 249 ng/mL (+/-82 ng/mL) respectively during level 1. The wordstem completion test frequencies at low level sedation were significantly higher than spontaneous frequencies (8.7% + 2.4%; P: sedation were accompanied by small differences in venous propofol or midazolam concentrations. This indicates steep concentration-effect relationships. Neutral information is still memorized during low-level sedation with both drugs. The memory effect of propofol and midazolam did not differ significantly. Implicit memory can occur during different states of consciousness and might lead to psychological damage. In 10 volunteers, implicit memory was investigated during sedation with propofol and midazolam in a double-blinded, placebo-controlled study. To compare the effects of both drugs, they were titrated using a computer-controlled infusion system to produce similar high and low levels of sedation.

  11. Induration at Injection or Infusion Site May Reduce Bioavailability of Parenteral Phenobarbital Administration.

    Science.gov (United States)

    Nakayama, Hirokazu; Echizen, Hirotoshi; Ogawa, Ryuichi; Akabane, Atsuya; Kato, Toshiaki; Orii, Takao

    2017-06-01

    Phenobarbital is well tolerated and effective for controlling agitation or preventing convulsion at the end of life. No information is available concerning parenteral bioavailability of phenobarbital when induration develops at the injection or infusion site. We investigated whether induration at injection or infusion site is related to phenobarbital bioavailability via parenteral routes of continuous subcutaneous infusion and intermittent subcutaneous or intramuscular injection. A retrospective analysis was conducted on the medical data obtained from 18 patients who received chronic subcutaneous or intramuscular injections of phenobarbital for the prevention of convulsions and underwent plasma concentration monitoring of the drug. Patients whose concomitant medications were altered during the observation periods were excluded from the analysis. Comparisons were performed for concentration/dose (C/D) ratios obtained from patients with induration at injection or infusion sites (induration group, n = 6) and those without induration (noninduration group, n = 12). P phenobarbital may be reduced when induration develops at the injection or infusion site in patients treated parenterally by continuous subcutaneous infusion or intramuscular injection.

  12. Clinical evaluation of preoperative arterial infusion chemotherapy and surgical operation for colorectal carcinoma

    International Nuclear Information System (INIS)

    Yuan Jianhua; Zhao Zhongsheng; Deng Gaoli; Hu Tingyang; Yu Wenqiang; Chen Fanghong; Luo Zuyan; Ru Guoqing; Dong Quanjin; Tu Shiliang

    2003-01-01

    Objective: To investigate the clinical values of preoperative arterial infusion chemotherapy and surgical operation for colorectal carcinoma. Methods: 66 patients with colorectal carcinoma were subjected to percutaneous femoral artery catheterization by Seldinger's technique with infusion of anti-cancer drugs. The resection was performed 5-30 days after the arterial infusion (mean 12 days). In 50 surgical specimens of the 66 cases, histological findings were evaluated including the density and distribution of the apoptosis cells under the observation by DNA nick end labelling technique. Of which 22 specimens before arterial infusion chemotherapy (got from biopsy of preoperation) and 25 normal mucosa (got from normal surgical specimens) were used as controls. Results: The total histological response rate was 100% with grade I in 20 cases, grade II in 21 cases, grade III in 9 cases. The densities of the apoptosis cells were 31.47 ± 5.58 before arterial infusion chemotherapy, 76.69 ± 17.12 after arterial infusion chemotherapy and 8.01 ± 3.39 in normal mucosa. The density of the apoptosis cells after arterial infusion chemotherapy was significantly higher than that before arterial infusion chemotherapy (P 2 =4.696, P>0.30). There were no significant differences in the apoptosis of adenocarcinoma during different pathological stages (F=0.001376, P>0.05). Conclusions: Peroperative transcatheter arterial infusion chemotherapy resulting in apoptosis of adenocarcinoma, can raise the radical operation rate, and prolong survival rate for colorectal carcinoma patients

  13. Open-Source Syringe Pump Library

    Science.gov (United States)

    Wijnen, Bas; Hunt, Emily J.; Anzalone, Gerald C.; Pearce, Joshua M.

    2014-01-01

    This article explores a new open-source method for developing and manufacturing high-quality scientific equipment suitable for use in virtually any laboratory. A syringe pump was designed using freely available open-source computer aided design (CAD) software and manufactured using an open-source RepRap 3-D printer and readily available parts. The design, bill of materials and assembly instructions are globally available to anyone wishing to use them. Details are provided covering the use of the CAD software and the RepRap 3-D printer. The use of an open-source Rasberry Pi computer as a wireless control device is also illustrated. Performance of the syringe pump was assessed and the methods used for assessment are detailed. The cost of the entire system, including the controller and web-based control interface, is on the order of 5% or less than one would expect to pay for a commercial syringe pump having similar performance. The design should suit the needs of a given research activity requiring a syringe pump including carefully controlled dosing of reagents, pharmaceuticals, and delivery of viscous 3-D printer media among other applications. PMID:25229451

  14. Cardiovascular effects of intravenous ghrelin infusion in healthy young men

    DEFF Research Database (Denmark)

    Vestergaard, Esben Thyssen; Andersen, Niels Holmark; Hansen, Troels Krarup

    2007-01-01

    Ghrelin infusion improves cardiac function in patients suffering from cardiac failure, and bolus administration of ghrelin increases cardiac output in healthy subjects. The cardiovascular effects of more continuous intravenous ghrelin exposure remain to be studied. We therefore studied the cardio......Ghrelin infusion improves cardiac function in patients suffering from cardiac failure, and bolus administration of ghrelin increases cardiac output in healthy subjects. The cardiovascular effects of more continuous intravenous ghrelin exposure remain to be studied. We therefore studied...... the cardiovascular effects of a constant infusion of human ghrelin at a rate of 5 pmol/kg per minute for 180 min. Fifteen healthy, young (aged 23.2 ± 0.5 yr), normal-weight (23.0 ± 0.4 kg/m2) men volunteered in a randomized double-blind, placebo-controlled crossover study. With the subjects remaining fasting, peak...... myocardial systolic velocity S′, tissue tracking TT, left ventricular ejection fraction EF, and endothelium-dependent flow-mediated vasodilatation were measured. Ghrelin infusion increased S′ 9% (P = 0.002) and TT 10% (P

  15. Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial

    NARCIS (Netherlands)

    Hermanides, J.; Nørgaard, K.; Bruttomesso, D.; Mathieu, C.; Frid, A.; Dayan, C. M.; Diem, P.; Fermon, C.; Wentholt, I. M. E.; Hoekstra, J. B. L.; DeVries, J. H.

    2011-01-01

    To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes. In this investigator-initiated multi-centre trial (the Eurythmics Trial) in eight outpatient centres in Europe, we randomized 83 patients with

  16. An Optimization Scheme for Water Pump Control in Smart Fish Farm with Efficient Energy Consumption

    Directory of Open Access Journals (Sweden)

    Israr Ullah

    2018-06-01

    Full Text Available Healthy fish production requires intensive care and ensuring stable and healthy production environment inside the farm tank is a challenging task. An Internet of Things (IoT based automated system is highly desirable that can continuously monitor the fish tanks with optimal resources utilization. Significant cost reduction can be achieved if farm equipment and water pumps are operated only when required using optimization schemes. In this paper, we present a general system design for smart fish farms. We have developed an optimization scheme for water pump control to maintain desired water level in fish tank with efficient energy consumption through appropriate selection of pumping flow rate and tank filling level. Proposed optimization scheme attempts to achieve a trade-off between pumping duration and flow rate through selection of optimized water level. Kalman filter algorithm is applied to remove error in sensor readings. We observed through simulation results that optimization scheme achieve significant reduction in energy consumption as compared to the two alternate schemes, i.e., pumping with maximum and minimum flow rates. Proposed system can help in collecting the data about the farm for long-term analysis and better decision making in future for efficient resource utilization and overall profit maximization.

  17. [Morphine self-administration by rats using a pneumatic syringe].

    Science.gov (United States)

    Akiyama, Y; Takayama, S

    1988-06-01

    An apparatus for drug self-administration by rats using a pneumatic syringe was developed by Weeks. A microliter syringe operated by a pneumatic cylinder supplies an accurate volume of drug solution within one second. When coefficient of variation of infusion volume was compared among pneumatic syringe, infusion pump, and peristaltic pump, pneumatic syringe showed higher accuracy in infusion volume than the other two pumps. Since the infusion speed by a pneumatic syringe is very rapid (less than one second per infusion), the effect of infusion speed on reinforcing property of morphine was investigated. When rats self-administered 0.1, 0.3, 1.0, and 3.0 mg/kg/infusion of morphine by pneumatic syringes, the patterns of self-infusion were more stable, the number of self-infusions and the amount self-administered were larger, and a dose-response relationship was clearer in comparison with those self-infused the same doses of morphine for 5.6 seconds by infusion pumps or peristaltic pumps.

  18. Responses to Starch Infusion on Milk Synthesis in Low Yield Lactating Dairy Cows

    Directory of Open Access Journals (Sweden)

    Yang Zou

    2015-09-01

    Full Text Available The effect of starch infusion on production, metabolic parameters and relative mRNA abundance was investigated in low yield lactating cows from 86 days in milk. Six Holstein cows fitted with permanent ruminal cannulas were arranged into one of two complete 3×3 Latin squares and infused with a starch solution containing 800 grams starch for 16 days. The three treatments were: i ruminal and abomasal infusion with water (Control; ii ruminal infusion with cornstarch solution and abomasal infusion with water (Rumen; iii ruminal infusion with water and abomasal infusion with cornstarch solution (Abomasum. There were no significant differences (p>0.05 among the three treatments with low yield lactating cows in feed and energy intake, milk yield and composition, plasma metabolism, or even on gene expression. However, cows receiving starch through rumen performed better than directly through the abomasum during the glucose tolerance test procedure with a higher area under the curve (AUC; p = 0.08 and shorter half-time (t1/2; p = 0.11 of plasma insulin, therefore, it increased glucose disposal, which stated a lipid anabolism other than mobilization after energy supplementation. In conclusion, extra starch infusion at concentration of 800 g/d did not enhance energy supplies to the mammary gland and improve the lactating performance in low yield lactating cows.

  19. Cost-effectiveness analysis of levobupivacaine 0.5 %, a local anesthetic, infusion in the surgical wound after modified radical mastectomy.

    Science.gov (United States)

    Ferreira Laso, Lourdes; López Picado, Amanda; Antoñanzas Villar, Fernando; Lamata de la Orden, Laura; Ceballos Garcia, Mar; Ibañez López, Carolina; Pipaon Ruilope, Lorena; Lamata Hernandez, Felix; Valero Martinez, Cesar; Aizpuru, Felipe; Hernandez Chaves, Roberto

    2015-09-01

    Effective treatment of postoperative pain contributes to decreasing the rate of complications as well as the total cost of the operated patients. The aim of this study was to analyze the costs and the efficiency of use of continuous infusion of levobupivacaine 0.5 % with the help of an infusion pump in modified radical mastectomy. A cost calculation of the analgesic procedures (continuous infusion of levobupivacaine 0.5 % [levobupivacaine group (LG)] or saline [saline group (SG)] (2 ml/h 48 h) has been carried out based on the data of a previous clinical trial (double-blind randomized study) of patients who underwent modified radical mastectomy surgery. The measure of the effectiveness was the point reduction of pain derived from the verbal numeric rating scale (VNRS). The usual incremental cost-effectiveness ratio (ICER) was performed. Considering only the intravenous analgesia, overall costs were lower in LG, as less analgesia was used (EUR14.06 ± 7.89 vs. 27.47 ± 14.79; p mastectomy, therefore providing patients with a higher quality of care in the prevention of pain. clinicaltrials.gov: reference number NCT01389934. http://clinicaltrials.gov/show/NCT01389934

  20. Decreasing the infusion rate reduces the proarrhythmic risk of NS-7

    DEFF Research Database (Denmark)

    Detre, Elke; Thomsen, Morten Bækgaard; Beekman, Jet D

    2005-01-01

    1 The rate of infusion has been suggested to be important for drug-induced torsades de pointes (TdP) arrhythmias. We investigated the repolarisation-prolonging effects and proarrhythmic properties of NS-7, a neuroprotective drug in development, using two different infusion rates. 2 A fast (5 min...... intravenously (i.v.)) escalating dosing regimen (0.3 and 3.0 mg kg(-1), n=4) of NS-7 was investigated in anaesthetised control dogs in sinus rhythm (SR). This was compared to a slow infusion (60 min i.v.) of one dose (3.0 mg kg(-1), n=4) NS-7. The similar dosing regimens were investigated in anaesthetised dogs...... with chronic, complete AV block (CAVB), an animal model of TdP (n=6). 3 No electrophysiological effects were seen after 0.3 mg kg(-1) NS-7. Fast infusion of 3.0 mg kg(-1) caused prolongation of repolarisation, for example, heart rate corrected QT interval (QT(c)): in SR: 6+/-1%; in CAVB: 10+/-7%, which...

  1. Assessment of quality of glycemic control in intensive care patients treated with an insulin infusion at a teaching hospital.

    Science.gov (United States)

    Gauthier, Lyne; Ferguson, Jessica; Dubé, Anne-Isabelle; Nguyen, Patrick Viet-Quoc; Beauchesne, Marie-France; Boutin, Jean-Marie

    2014-04-01

    To describe the quality of glycemic control in patients in intensive care units (ICUs) treated with an intravenous (IV) insulin infusion at a teaching hospital. This retrospective study included patients admitted to the ICU and treated with an IV insulin infusion for at least 12 h between August 1 and November 30, 2011. Medical charts were reviewed. The primary quality indicator for glycemic control was the mean percent of blood glucose values per patient in the 6.1 to 8 mmol/L target range. A total of 351 patients were included; 61.5% of subjects had no known diabetes. Admissions were mainly for surgery (61.3%). The mean Acute Physiology and Chronic Health Evaluation (APACHE) II score was 16.8±7.3. The mean percent of blood glucose values per patient in the 6.1 to 8 mmol/L range was 35% for all subjects and 26.2% for patients with diabetes. If a target of 6.1 to 10 mmol/L was considered, those values became 63% and 54.6%. At least 1 episode of hyperglycemia (>10 mmol/L), hypoglycemia (quality of glycemic control in patients in the ICU at our hospital needs to be improved. A new computerized IV insulin protocol is currently being tested. Copyright © 2014 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  2. Open-loop glucose control: Automatic IOB-based super-bolus feature for commercial insulin pumps.

    Science.gov (United States)

    Rosales, Nicolás; De Battista, Hernán; Vehí, Josep; Garelli, Fabricio

    2018-06-01

    Although there has been significant progress towards closed-loop type 1 diabetes mellitus (T1DM) treatments, most diabetic patients still treat this metabolic disorder in an open-loop manner, based on insulin pump therapy (basal and bolus insulin infusion). This paper presents a method for automatic insulin bolus shaping based on insulin-on-board (IOB) as an alternative to conventional bolus dosing. The methodology presented allows the pump to generate the so-called super-bolus (SB) employing a two-compartment IOB dynamic model. The extra amount of insulin to boost the bolus and the basal cutoff time are computed using the duration of insulin action (DIA). In this way, the pump automatically re-establishes basal insulin when IOB reaches its basal level. Thus, detrimental transients caused by manual or a-priori computations are avoided. The potential of this method is illustrated via in-silico trials over a 30 patients cohort in single meal and single day scenarios. In the first ones, improvements were found (standard treatment vs. automatic SB) both in percentage time in euglycemia (75g meal: 81.9 ± 15.59 vs. 89.51 ± 11.95, ρ ≃ 0; 100g meal: 75.12 ± 18.23 vs. 85.46 ± 14.96, ρ ≃ 0) and time in hypoglecymia (75g meal: 5.92 ± 14.48 vs. 0.97 ± 4.15, ρ=0.008; 100g meal: 9.5 ± 17.02 vs. 1.85 ± 7.05, ρ=0.014). In a single day scenario, considering intra-patient variability, the time in hypoglycemia was reduced (9.57 ± 14.48 vs. 4.21 ± 6.18, ρ=0.028) and improved the time in euglycemia (79.46 ± 17.46 vs. 86.29 ± 11.73, ρ=0.007). The automatic IOB-based SB has the potential of a better performance in comparison with the standard treatment, particularly for high glycemic index meals with high carbohydrate content. Both glucose excursion and time spent in hypoglycemia were reduced. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Continuous Intravenous Sub-Dissociative Dose Ketamine Infusion for Managing Pain in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Jefferson Drapkin

    2018-03-01

    Full Text Available Introduction: Our objective was to describe dosing, duration, and pre- and post-infusion analgesic administration of continuous intravenous sub-dissociative dose ketamine (SDK infusion for managing a variety of painful conditions in the emergency department (ED. Methods: We conducted a retrospective chart review of patients aged 18 and older presenting to the ED with acute and chronic painful conditions who received continuous SDK infusion in the ED for a period over six years (2010–2016. Primary data analyses included dosing and duration of infusion, rates of pre- and post-infusion analgesic administration, and final diagnoses. Secondary data included pre- and post-infusion pain scores and rates of side effects. Results: A total of 104 patients were enrolled in the study. Average dosing of SDK infusion was 11.26 mg/hr, and the mean duration of infusion was 135.87 minutes. There was a 38% increase in patients not requiring post-infusion analgesia. The average decrease in pain score was 5.04. There were 12 reported adverse effects, with nausea being the most prevalent. Conclusion: Continuous intravenous SDK infusion has a role in controlling pain of various etiologies in the ED with a potential to reduce the need for co-analgesics or rescue analgesic administration. There is a need for more robust, prospective, randomized trials that will further evaluate the analgesic efficacy and safety of this modality across a wide range of pain syndromes and different age groups in the ED.

  4. Combined radiosensitizer infusion and irradiation of osteogenic sarcomas

    International Nuclear Information System (INIS)

    Goffinet, D.R.; Kaplan, H.S.; Donaldson, S.S.; Bagshaw, M.A.; Wilbur, J.R.

    1975-01-01

    Three children with osteogenic sarcomas which were either unresectable or whose parents refused permission to amputate were treated with combined intra-arterial 5'bromodeoxyuridine (BUdR) infusion and high-dose-per-fraction megavoltage irradiation to the primary site. Pulsed, 48-hour BUdR infusions were performed prior to each 600-rad radiation therapy fraction, with a total radiation dose to the primary site of 4,200 to 4,800 rads in five weeks. Local control was obtained in all 3 children. One child is alive two years after treatment, another died with metastatic disease, and the third patient who received radiotherapy to the lungs for pulmonary metastases is without evidence of disease one year later. (auth)

  5. Parallel operation of primary sodium pumps in FBTR

    International Nuclear Information System (INIS)

    Athmalingam, S.; Ellappan, T.R.; Vaidyanathan, G.; Chetal, S.C.; Bhoje, S.B.

    1994-01-01

    Sodium pumps used in the primary main circuit of Fast Breeder Test Reactor (FBTR) are centrifugal pumps. These pumps have a free level of sodium with a cover gas above it to simplify the pump seal arrangement. The sodium level in the pumps will vary based on the flow. The minimum level is governed by consideration of gas entrainment and net positive suction head (NPSH) to the pump while the maximum level is limited by sodium entering the pump tank gas line. There is a special feature in these pumps in that a small portion of the pump outlet sodium flow is led back into the suction chamber to maintain level and avoid gas entrainment. A control valve in this line helps in controlling the level at the desired value. With parallel operation of two sodium pumps a study was conducted to find the regions of safe operation of the two pumps. The purpose of this paper is to give the various design features and methodology of the analysis to arrive at the limiting condition of operation for the different operating states of the two pumps and the effect of pump speed variations on the fluctuations in sodium flows. (author). 6 figs

  6. [A Case of HPN, In Which QOL Improvement Was Achieved by Combining Continuous Infusion with Once-Weekly Intermittent Infusion - Contribution of Pharmacists to Health Promotion among Home Patients Receiving Infusion Therapy].

    Science.gov (United States)

    Takeda, Namihiro; Hamana, Tomoko; Oka, Toyoka; Hirohara, Masayoshi; Kushida, Kazuki

    2016-12-01

    Patients receiving parenteral nutrition at home have the following two options: 24-h continuous or intermittent infusion. To date, for patients with impaired glucose tolerance and/or other metabolic disorders or for those with decreased cardiac/ pulmonary/renal function, it is desirable to opt for continuous infusion to minimize the variance in the body's metabolic rate as much as possible. Furthermore, it should be noted that continuous infusion evokes a stronger feeling among patients of being constrained because it restricts their everyday activities. This case witnesses collaborations among the patient's doctor, dispensary's pharmacy, and patient's family. Because ofthe use ofintermittent infusion more or less once per week in addition to continuous infusion, significant improvement in quality of life was achieved, and the patient was able to enjoy taking a short trip. To assist a home patient receiving infusion therapy, it is essential that the pharmacist be equipped with skills to manage risks associated with infusion therapy and have knowledge about insurance to cover incidents concerning infusion fluids or medical materials. It will certainly depend on the degree ofindependence ofpatients and the level ofcare their families can provide; however, should we manage to use a similar medical procedure in at least a few cases in the future, we may be able to contribute to "joie de vivre" in home patients receiving infusion therapy.

  7. Pumping behavior of sputter ion pumps

    International Nuclear Information System (INIS)

    Chou, T.S.; McCafferty, D.

    The ultrahigh vacuum requirements of ISABELLE is obtained by distributed pumping stations. Each pumping station consists of 1000 l/s titanium sublimation pump for active gases (N 2 , H 2 , O 2 , CO, etc.), and a 20 l/s sputter ion pump for inert gases (methane, noble gases like He, etc.). The combination of the alarming production rate of methane from titanium sublimation pumps (TSP) and the decreasing pumping speed of sputter ion pumps (SIP) in the ultrahigh vacuum region (UHV) leads us to investigate this problem. In this paper, we first describe the essential physics and chemistry of the SIP in a very clean condition, followed by a discussion of our measuring techniques. Finally measured methane, argon and helium pumping speeds are presented for three different ion pumps in the range of 10 -6 to 10 -11 Torr. The virtues of the best pump are also discussed

  8. Continuous venovenous haemodialysis

    DEFF Research Database (Denmark)

    Jensen, Dorte Møller; Bistrup, C; Pedersen, R S

    1996-01-01

    A simple three-pump-based system for the performance of continuous venovenous haemodialysis is described. The method employs access to the circulation via a double-lumen catheter, and by means of a standard extracorporeal peristaltic pump the blood is circulated through a haemofiltration filter....... Standard solutions for peritoneal dialysis are administered in a single-pass manner countercurrent to the blood flow. To control the dialysate flow through the filter, two separate pumps designed for intravenous infusion are used. Anticoagulation is achieved by means of continuous heparin infusion....... This three-pump system is effective in controlling the fluid balance and the level of azotemia. Furthermore, this system makes haemodialysis possible in spite of severe haemodynamic instability. The system is easy to use and inexpensive. 3 patients participated in the study....

  9. Pump efficiency in solar-energy systems

    Science.gov (United States)

    1978-01-01

    Study investigates characteristics of typical off-the-shelf pumping systems that might be used in solar systems. Report includes discussion of difficulties in predicting pump efficiency from manufacturers' data. Sample calculations are given. Peak efficiencies, flow-rate control, and noise levels are investigated. Review or theory of pumps types and operating characteristics is presented.

  10. Energy Saving Potential in Knuckle Boom Cranes using a Novel Pump Controlled Cylinder Drive

    Directory of Open Access Journals (Sweden)

    Søren Ketelsen

    2018-04-01

    Full Text Available This paper is considering the application of a novel pump controlled cylinder drive, the so-called Speed-variable Switched Differential Pump (SvSDP, for knuckle boom crane actuation. Especially the control system for the SvSDP drive is considered, and aiming on improving energy efficiency a refinement of the existing control structure is proposed. An energy efficient sizing algorithm for the SvSDP drive is developed, and fundamental differences between the achievable operating range for the SvSDP drive compared to a conventional valve-cylinder drive are discussed. A case study is conducted with knuckle boom crane actuation, and compared to a conventional valve actuation. Simulation results show that the motion tracking performance is on a similar level compared to the valve actuation approach, while the energy consumption is drastically decreased. For the given test trajectory the valve actuation system consumes 0.79 kWh of electrical energy, while the SvSDP drive consume 0.06 kWh, if ideal energy recovery and storage is assumed.

  11. Improving the technique of water infusion to control dust in the mines of the central district of the Donetz coalfield

    Energy Technology Data Exchange (ETDEWEB)

    Aleksandrov, S N

    1974-03-01

    A study of the results obtained with different methods of water infusion is followed by an account of a new ''pinpoint'' infusion technique utilizing rising infusion holes of limited depth (20-25 m). This new technique enhances safety of work at the coal face, since it avoids deterioraon of the face due to erosion of surrounding walls and accumulation of gas in the infusion holes; it also renders the arduous job of guided drilling and sealing of the holes unnecessary, and facilitates coal-getting and development work.

  12. Infusion-related reactions to infliximab in patients with rheumatoid arthritis in a clinical practice setting: relationship to dose, antihistamine pretreatment, and infusion number.

    Science.gov (United States)

    Wasserman, Michael J; Weber, Deborah A; Guthrie, Judith A; Bykerk, Vivian P; Lee, Peter; Keystone, Edward C

    2004-10-01

    We describe infusion-related reactions to infliximab (during infusion or within 1 hour postinfusion) in patients with active rheumatoid arthritis (RA) treated in a quaternary care center. We followed 113 patients for a mean of 60.6 +/- 28.9 weeks, obtaining 10.5 +/- 4.9 infusions per patient. We observed 1183 infusions resulting in 104 infusion reactions (8.8%). All reactions resolved within several hours following cessation of the infusion and none was serious enough to warrant hospitalization. Reactions included allergic reactions (pruritus, urticaria) in 4.2% of infusions, cardiopulmonary (hypotension, hypertension, tachycardia) in 3.0%, and miscellaneous reactions (headache, nausea, vomiting) in 2.0%. Reactions occurred in 8.0% of 3 mg/kg infusions and in 10.3% of 5 mg/kg infusions. Reactions occurred in 13.2% of infusions that involved antihistamine pretreatment compared to only 7.5% of infusions that involved no pretreatment. At both infliximab doses, there was a similar frequency of infusion reactions in patients pretreated due to a previous infusion (12.6%) compared to those pretreated strictly based on infusion number (14.7%). A number of the reactions involving antihistamine pretreatment may be explained by known side effects of diphenhydramine, including headache, dizziness, nausea, and palpitations. Infusion-related reactions to infliximab were infrequent, rarely severe, and easily manageable. The frequency of reactions was equivalent in patients treated with 3 mg/kg compared to 5 mg/kg. Reactions were significantly more frequent in infusions where patients were pretreated with the antihistamine diphenhydramine, compared to those not involving pretreatment.

  13. Palliation of inoperable head and neck cancer: combined intra-arterial infusion chemotherapy and irradiation

    International Nuclear Information System (INIS)

    Armstrong, A.L.; Meeker, W.R.

    1978-01-01

    Palliation of unresectable head and neck cancer remains a difficult problem. Because of excellent results reported by others with infusion of vinblastine, methotrexate, and 5-fluorouracil into the external carotid artery followed by irradiation before curative surgery, we applied this technic to 22 patients with advanced head and neck cancer. Fifteen patients from this group who had chemotherapy infusion followed by radiation therapy are compared with 21 patients who received radiation therapy alone. Both groups were similar in distribution of primary site, histology, and TNM stage. Of 15 patients, 14 (93%) had partial or complete tumor regression after both arterial chemotherapy infusion and irradiation, while 14 of 17 patients (82%) receiving primary irradiation had partial or complete response. Drug toxicity and complications related to infusion occurred in all patients. Most patients in both groups had short survivals (mean of 14.1 months in infusion chemotherapy and radiation vs 9.1 months in primary irradiation). One patient remains alive in the infusion group and two in the control group; however, all have recurrent disease. Results indicate a slight increase in survival time with the addition of infusion chemotherapy to irradiation in palliative treatment of head and neck cancer

  14. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid N

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5489. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''N''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document

  15. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid M

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5073. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''M''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document

  16. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid L

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5055. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''L''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document

  17. Extended infusion versus intermittent infusion of imipenem in the treatment of ventilator-associated pneumonia.

    Science.gov (United States)

    Ibrahim, Mohamed M; Tammam, Tarek Fouad; Ebaed, Mohy El Deen; Sarhan, Hatem A; Gad, Gamal F; Hussein, Amal K

    2017-01-01

    Mechanical ventilation support can be the main source of ventilator-associated pneumonia (VAP). VAP is a serious infection that may be associated with dangerous gram-negative bacteria mainly, and it leads to an increase in the mortality in the intensive care unit (ICU). Imipenem is one of the strongest antibiotics now available for treating VAP which is associated with gram-negative and gram-positive bacteria, and it belongs to beta-lactam antibiotic group (carbapenem). This study tried to investigate the efficacy of imipenem against VAP when it was infused within 180 min versus the efficacy when it was infused within 30-60 min. This study was conducted in main ICU in general hospital which consists of surgical and medical beds within 2 years. One hundred and eighty-seven patients were enrolled on it. This study is a retrospective cohort which was conducted within 2 years. The efficacy of imipenem which was administered by intermittent infusion (30-60 min) within first year was compared with the efficacy of imipenem which was administered by extended infusion (180 min) within second year in the field of VAP curing and cost reduction. All data were collected retrospectively from patient medical files and were statistically analyzed by SPSS version 20. The study was designed to measure clinical and cost reduction outcomes, mortality and hospital stay. The results indicated that there is a significant decrease in mortality, number of recurrent infection, and ICU stay length, and the number of mechanical ventilator days was associated with extended imipenem infusion during the second year of the study. The use of imipenem with extended infusion over 3 hours enhances its clinical outcomes in the treatment of VAP.

  18. Hot sanitary water production with CO_2 heat pumps: Effect of control strategy on system performance and stratification inside the storage tank

    International Nuclear Information System (INIS)

    Tammaro, M.; Mauro, A.W.; Montagud, C.; Corberán, J.M.; Mastrullo, R.

    2016-01-01

    In this work three different control strategies for the production of sanitary hot water by means of an electric heat pump working with CO_2 are investigated. The heat pump is a prototype, here modelled in the vapour-compression software package IMST-ART. By simulating this model, the performance of the heat pump is correlated to the boundary conditions and is scaled to different sizes, namely 1, 1.5, and 2 times larger than the reference system. After having chosen an application for which the load profile of sanitary hot water during the year is known, these heat pumps are simulated in a TRNSYS16 model where the production of sanitary hot water and the consumption are buffered by the presence of a tank. Key parameter in guaranteeing comfort and good performance of the system is the stratification inside the storage tank. The size of the tank necessary to keep a certain level of comfort at the user is then determined through a parametric analysis for each size of the heat pump. The energetic performance is also evaluated for each system in terms of seasonal performance factor. Then, the results obtained are compared with a different system where the heat pump is equipped with an inverter and the circulation pump follows a different control logic. The size of the tank and the seasonal performance factor are therefore determined in this case too. Moreover, a “night&day” control logic is compared to these first two options to have a baseline of comparison in terms of volume of storage needed to guarantee a same level of comfort and performance. To provide information also on the running costs, a parametric analysis was run varying the type of control, the heat pump and the tank sizes for different load profiles. The results show that the size of the heat pump has a significant effect on the comfort of the user, which usually leads to oversizing of the storage tank when the load profile is unknown. With regard to this, the results obtained for the alternative

  19. Operational Test Report (OTR) for U-105 Pumping and Instrumentation and Control (PIC) Skid

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    Attached is the completed Operation Test Procedure (OTP-200-004, Rev. A-18). OTP includes a print out of the Programmable Logic Controller (PLC) Ladder Diagram. Ladder Diagram was designed for installation in the PLC used to monitor and control pumping activity for Tank Farm 241-U-105. The completed OTP and OTR are referenced in the IS PIC Skid Configuration Drawing (H-2-829998)

  20. Operational Test Report (OTR) for U-105 Pumping and Instrumentation and Control (PIC) Skid

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-28

    Attached is the completed Operation Test Procedure (OTP-200-004, Rev. A-18). OTP includes a print out of the Programmable Logic Controller (PLC) Ladder Diagram. Ladder Diagram was designed for installation in the PLC used to monitor and control pumping activity for Tank Farm 241-U-105. The completed OTP and OTR are referenced in the IS PIC Skid Configuration Drawing (H-2-829998).

  1. Operational Test Report (OTR) for U-103 Pumping and Instrumentation and Control (PIC) Skid

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-28

    Attached is the completed Operation Test Procedure (OTP-200-004, Rev. A-16). OTP includes a print out of the Programmable Logic Controller (PLC) Ladder Diagram. Ladder Diagram was designed for installation in the PLC used to monitor and control pumping activity for Tank Farm 241-U-103. The completed OTP and OTR are referenced in the 25 PIC Skid Configuration Drawing (H-2-829998).

  2. Speed control of boiler feed water pump turbine based on gray correlation compensation

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Yun Long; Wang, Di; Zhou, Hai Chun [Northeast Dianli UniversityJilin (China)

    2017-01-15

    One of the most important controlled parameters of thermal power units is the boiler drum water level. Disturbances of feed water flow rate could cause instability of the drum water level. This study proposes the Gray correlation compensation (GCC) control technology for the Boiler feed water pump turbine (BFPT) to solve this problem. Simulation results indicate that the GCC controller outperforms the traditional proportional-integral-derivative controller when it encounters different disturbances. Furthermore, the GCC controller can rapidly switch to the high-pressure steam source to ensure that the drum water level is in the secure range during steam source switching of the BFPT.

  3. Na(+)/K(+) pump interacts with the h-current to control bursting activity in central pattern generator neurons of leeches.

    Science.gov (United States)

    Kueh, Daniel; Barnett, William H; Cymbalyuk, Gennady S; Calabrese, Ronald L

    2016-09-02

    The dynamics of different ionic currents shape the bursting activity of neurons and networks that control motor output. Despite being ubiquitous in all animal cells, the contribution of the Na(+)/K(+) pump current to such bursting activity has not been well studied. We used monensin, a Na(+)/H(+) antiporter, to examine the role of the pump on the bursting activity of oscillator heart interneurons in leeches. When we stimulated the pump with monensin, the period of these neurons decreased significantly, an effect that was prevented or reversed when the h-current was blocked by Cs(+). The decreased period could also occur if the pump was inhibited with strophanthidin or K(+)-free saline. Our monensin results were reproduced in model, which explains the pump's contributions to bursting activity based on Na(+) dynamics. Our results indicate that a dynamically oscillating pump current that interacts with the h-current can regulate the bursting activity of neurons and networks.

  4. Swelling and infusion of tea in tea bags.

    Science.gov (United States)

    Yadav, Geeta U; Joshi, Bhushan S; Patwardhan, Ashwin W; Singh, Gurmeet

    2017-07-01

    The present study deals with swelling and infusion kinetics of tea granules in tea bags. The swelling and infusion kinetics of tea bags differing in tea loading and tea bag shapes were compared with loose tea. Increment in temperature and dipping frequency of tea bag in hot water increased the infusion kinetics of tea bags. Reduction in particle size enhanced the swelling and infusion kinetics of tea in a tea bag. The effects of tea particle size, tea bag dipping rate, loading of tea granules in tea bag and tea bag shapes on infusion kinetics were investigated. Increase in tea loading in tea bags resulted in reduced infusion kinetics. Double chambered tea bag showed the highest swelling (30%) and infusion kinetics (8.30% Gallic acid equivalence) while single chambered tea bags showed the lowest kinetics, amongst the various bags studied. The swelling and infusion kinetics of loose tea was always faster and higher than that of tea bags. It was found that overall effect of percentage filling of tea granules and height of tea bed in a tea bag affects tea infusion kinetics the most. Weibull model was found to be in good agreement with the swelling data.

  5. Ubiquitous Sensor Networks: Efisiensi Sistem Kontrol Cairan Infus Pasien Rawat Inap

    Directory of Open Access Journals (Sweden)

    BUDI RAHMADYA

    2018-02-01

    This research discusses about intravenous fluids Control System on Patients, utilizing sensor network technology and Arduino Uno microcontroller. We used  HC-SR04 Ultrasonic sensors to detect the review time intravenous fluids. The sensors data is readable by transmitted using wireless network/wireless from Transmitter (Tx in Patients Into Space Receiver (Rx at nurse room with using XBee wireless device S2. The efficiency of the control system were made, namely when the sensor detects the approaching limits of intravenous fluids discharged liquid that has been determined then the motor that was on the infus line will serve to close the infusion fluid flow in the line. In our simulations we found, the findings obtained Presentation intravenous fluids altitude error is 1.96% and presentations volume Liquid error is 2.16%. The performance of network devices XBee S2 have been tried, wireless data from the XBee end devices coordinator in this research. Keywords: Infusion, Sensor Networks, HC-SR04 Ultrasonic Sensor, XBee S2 And Microcontroller Arduino Uno.

  6. Effect of alcohol and glucose infusion on pituitary-gonadal hormones in normal females

    DEFF Research Database (Denmark)

    Becker, U; Gluud, C; Bennett, Patrick

    1988-01-01

    after 8 h. Four of the women participated in a control experiment with infusion of an equal volume of glucose 5.5%. Venous blood samples were drawn 5 times during the 24-h follow up period. Serum concentrations of sex steroids and pituitary hormones decreased in both ethanol and control experiments...... and the results did not differ significantly. The lowest hormone concentrations were observed 1-5 h after the start of infusion. Oestradiol, oestrone and oestrone-sulphate concentrations decreased 24-46% compared to basal values. 5 alpha-dihydro-testosterone levels decreased 23-31%, androstenedione...

  7. A Model for the Application of Target-Controlled Intravenous Infusion for a Prolonged Immersive DMT Psychedelic Experience

    Directory of Open Access Journals (Sweden)

    Andrew Robert Gallimore

    2016-07-01

    Full Text Available The state of consciousness induced by N,N-dimethyltryptamine (DMT is one of the most extraordinary of any naturally-occurring psychedelic substance. Users consistently report the complete replacement of normal subjective experience with a novel alternate universe, often densely populated with a variety of strange objects and other highly complex visual content, including what appear to be sentient beings. The phenomenology of the DMT state is of great interest to psychology and calls for rigorous academic enquiry. The extremely short duration of DMT effects—less than 20 minutes—militates against single dose administration as the ideal model for such enquiry. Using pharmacokinetic modelling and DMT blood sampling data, we demonstrate that the unique pharmacological characteristics of DMT, which also include a rapid onset and lack of acute tolerance to its subjective effects, make it amenable to administration by target-controlled intravenous infusion. This is a technology developed to maintain a stable brain concentration of anaesthetic drugs during surgery. Simulations of our model demonstrate that this approach will allow research subjects to be induced into a stable and prolonged DMT experience, making it possible to carefully observe its psychological contents, and provide more extensive accounts for subsequent analyses. This model would also be valuable in performing functional neuroimaging, where subjects are required to remain under the influence of the drug for extended periods. Finally, target-controlled intravenous infusion of DMT may aid the development of unique psychotherapeutic applications of this psychedelic agent.

  8. Evaluation of pharmacokinetic model designs for subcutaneous infusion of insulin aspart

    DEFF Research Database (Denmark)

    Mansell, Erin J.; Schmidt, Signe; Docherty, Paul D.

    2017-01-01

    Effective mathematical modelling of continuous subcutaneous infusion pharmacokinetics should aid understanding and control in insulin therapy. Thorough analysis of candidate model performance is important for selecting the appropriate models. Eight candidate models for insulin pharmacokinetics...... included a range of modelled behaviours, parameters and complexity. The models were compared using clinical data from subjects with type 1 diabetes with continuous subcutaneous insulin infusion. Performance of the models was compared through several analyses: R2 for goodness of fit; the Akaike Information...

  9. Computer system design description for the spare pump mini-dacs data acquisition and control system

    International Nuclear Information System (INIS)

    Vargo, G.F. Jr.

    1994-01-01

    The attached document outlines the computer software design for the mini data acquisition and control system (DACS), that supports the testing of the spare pump for Tank 241-SY-101, at the maintenance and storage facility (MASF)

  10. Follow-up at the corrected age of 24 months of preterm newborns receiving continuous infusion of fentanyl for pain control during mechanical ventilation.

    Science.gov (United States)

    Ancora, Gina; Lago, Paola; Garetti, Elisabetta; Pirelli, Anna; Merazzi, Daniele; Pierantoni, Luca; Ferrari, Fabrizio; Faldella, Giacomo

    2017-05-01

    The neurodevelopmental impact of fentanyl given to preterm newborns for pain control is still unknown. The aim of this study was to assess the neurodevelopmental impact of 2 regimens of fentanyl administration by a prospective follow-up evaluation. In our previous multicenter, double-blind, randomized controlled trial, 131 mechanically ventilated newborns (gestational age ≤32 weeks) were randomized to fentanyl (continuous infusion of fentanyl + open label boluses of fentanyl) or placebo (continuous infusion of placebo + open label boluses of fentanyl). Infant development was evaluated using Griffiths Mental Developmental Scales (Griffiths, 1996) until 24 months of corrected age by trained psychologists who were not aware of the group allocation. 106/131 infants survived at discharge; 3 died after discharge, 25 were lost to follow-up (12 in the fentanyl and 13 in the placebo group). Seventy-eight patients were evaluated at 2 years of corrected age. Children in the fentanyl group, compared with those in the placebo group, obtained significantly lower Griffiths general developmental quotient (mean [SD]: 89.95 [13.64] vs 97.18 [12.72], P = 0.024) together with the scores on the eye-hand coordination (mean [SD]: 89.09 [12.13] vs 99.19 [13.19], P = 0.002) and performance skills (mean [SD]: 79.71 [15.80] vs 90.09 [15.28], P = 0.009) scales. After adjustment for clinical confounders (gestational age, CRIB score, and sex) only eye-hand co-ordination was associated with fentanyl infusion. This study demonstrates that continuous infusion of fentanyl in very preterm infants, given at 1 mcg·kg·h during mechanical ventilation, is associated with a significant decrease in eye and hand co-ordination skills. Longer follow-up is needed to evaluate the impact on future motor, cognitive, and behavioral functions.

  11. Reactor coolant pumps for nuclear reactors

    International Nuclear Information System (INIS)

    Harand, E.; Richter, G.; Tschoepel, G.

    1975-01-01

    A brake for the pump rotor of a main coolant pump or a shutoff member on the pump are provided in order to prevent excess speeds of the pump rotor. Such excess speeds may occur in PWR type reactors with water at a pressure below, e.g., 150 bars if there is leakage from a coolant line associated with the main coolant pump. As a brake, a centrifugal brake depending upon the pump speed or a brake ring arranged on the pump housing and acting on the pump rotor, which ring would be activated by pressure differentials in the pump, may be used. If the pressure differences between suction and pressure sockets are very small, a controlled hydraulic increase of the pressure force on the brake may also be provided. Furthermore, a turbine brake may be provided. A slide which is automatically movable in closing position along the pump rotor axis is used as a shutoff element. It is of cylindrical configuration and is arranged concentrically with the rotor axis. (DG) [de

  12. Prostaglandin synthesis can be inhibited locally by infusion of NSAIDS through microdialysis catheters in human skeletal muscle

    DEFF Research Database (Denmark)

    Mikkelsen, Ulla Ramer; Helmark, Ida Carøe; Kjaer, Michael

    2008-01-01

    of nonsteroidal anti-inflammatory drugs (NSAIDs). However, to study the local role of prostaglandins, the formation of prostaglandins within the tissue must be controlled. Microdialysis enables determination of local concentrations of water-soluble substances within the tissue. In the present study......, the microdialysis method was used to infuse NSAIDs locally into human skeletal muscles producing a local block of prostaglandin formation. In addition, the graded blockade at various distances from the infusion site within the muscle during rest, exercise and recovery was determined. Microdialysis was performed...... in thigh muscles (vastus lateralis muscle) in six healthy men. One of the microdialysis catheters was used to block prostaglandin synthesis by infusion of the NSAID indomethacin. Additional catheters were placed 1 and 4 cm away from the infusion and in the contralateral leg (working control). Following 2 h...

  13. Infusion's greenfield subsidiary in Poland

    NARCIS (Netherlands)

    Williams, C.; van Eerde, W.; The, D.

    2012-01-01

    The president of Infusion Development Corporation was reviewing the progress of the new subsidiary the company had set up 15 months earlier in Krakow, Poland. The purpose of the subsidiary was to work with other Infusion offices around the world to provide innovative software development services to

  14. Miniature Scroll Pumps Fabricated by LIGA

    Science.gov (United States)

    Wiberg, Dean; Shcheglov, Kirill; White, Victor; Bae, Sam

    2009-01-01

    Miniature scroll pumps have been proposed as roughing pumps (low - vacuum pumps) for miniature scientific instruments (e.g., portable mass spectrometers and gas analyzers) that depend on vacuum. The larger scroll pumps used as roughing pumps in some older vacuum systems are fabricated by conventional machining. Typically, such an older scroll pump includes (1) an electric motor with an eccentric shaft to generate orbital motion of a scroll and (2) conventional bearings to restrict the orbital motion to a circle. The proposed miniature scroll pumps would differ from the prior, larger ones in both design and fabrication. A miniature scroll pump would include two scrolls: one mounted on a stationary baseplate and one on a flexure stage (see figure). An electromagnetic actuator in the form of two pairs of voice coils in a push-pull configuration would make the flexure stage move in the desired circular orbit. The capacitance between the scrolls would be monitored to provide position (gap) feedback to a control system that would adjust the drive signals applied to the voice coils to maintain the circular orbit as needed for precise sealing of the scrolls. To minimize power consumption and maximize precision of control, the flexure stage would be driven at the frequency of its mechanical resonance. The miniaturization of these pumps would entail both operational and manufacturing tolerances of pump components. In addition, the vibrations of conventional motors and ball bearings exceed these tight tolerances by an order of magnitude. Therefore, the proposed pumps would be fabricated by the microfabrication method known by the German acronym LIGA ( lithographie, galvanoformung, abformung, which means lithography, electroforming, molding) because LIGA has been shown to be capable of providing the required tolerances at large aspect ratios.

  15. Operational Test Report (OTR) for U-102 Pumping and Instrumentation and Control (PIC) Skid

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-28

    Attached is the completed Operation Test Procedure (OTP-200-004, Rev. A-19 and Rev. A-20). OTP includes a print out of the Programmable Logic Controller (PLC) Ladder Diagram. Ladder Diagram was designed for installation in the PLC used to monitor and control pumping activity for Tank Farm 241-U-102. The completed OTP and OTR are referenced in the IS PIC Skid Configuration Drawing (H-2-829998).

  16. Operation and control strategies in pre-series testing of cold circulating pumps for ITER

    International Nuclear Information System (INIS)

    Bhattacharya, R.; Vaghela, H.; Sarkar, B.; Srinivas, M.; Choukekar, K.

    2013-01-01

    Cryo-distribution system of ITER is responsible for the distribution and control of forced-flow supercritical helium for cooling of the superconducting magnets and the cryo-pumps. The requirements of cold circulating pumps (CCP) for mass flow rates and performance are much higher than presently existing and commercially available one used at 4.0 K helium. Design up-scaling with pre-series test of CCP has been proposed including test infrastructure. Operation and control strategies for the test distribution box (TDB) of test infrastructure have been developed and analyzed using steady state and dynamic process simulation to cope with the functional requirements of CCPs. Off-normal scenario with CCP inlet pressure variation is an important concern, dynamic process responses during such scenario have been evaluated to verify the operability of CCP. The paper describes process simulation to cope with the functional requirements of CCPs along with evaluation of off-normal scenario to verify the operability of CCP. (author)

  17. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid L

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    1999-11-09

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5055. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''L''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document.

  18. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid M

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    1999-12-13

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5073. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''M''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document.

  19. Continuous infusion of tracer norepinephrine may miscalculate unidirectional nerve uptake of norepinephrine in humans

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Christensen, N J; Ring-Larsen, H

    1989-01-01

    In order to evaluate uptake kinetics of norepinephrine (NE) in different tissues, a catheterization study was performed in control subjects (n = 6) and patients with enhanced sympathetic nervous activity (cirrhosis, n = 12) during constant intravenous infusion of L[3H]norepinephrine ([3H]NE) for 75...... minutes. In spite of a higher NE spillover from kidneys in patients compared with controls (82 vs. 49 ng/min, p less than 0.01), renal extraction ratios of [3H]NE were similar in the two groups (0.33 vs. 0.32, NS), and no significant change was observed during the time of infusion. In contrast, liver......-intestine extraction ratios of [3H]NE decreased significantly and equally with infusion time in patients (from 0.57 to 0.44, p less than 0.01) and controls (from 0.59 to 0.46, p less than 0.01). This was observed despite the fact that spillover of NE from this vascular bed was observed only in patients with cirrhosis...

  20. Stem infusion of nitrogen-15 to quantify nitrogen remobilization in maize

    International Nuclear Information System (INIS)

    Ma, B.L.; Dwyer, L.M.; Tollenaar, M.; Smith, D.L.

    1998-01-01

    Nitrogen (N) use efficiency (NUE) of fertilizer N can be accurately estimated by tracing the fate of soil applied labelled fertilizer, but the quantity of N remobilization from non-kernel components into kernels in maize (Zea mays L.) plants is difficult to determine. A field experiment involving stem infusion with labelled 15N solution was conducted at Ottawa, Ontario (45 degrees 22'N, 75 degrees 43'W) for two years to determine whether stem infused 15N could be used to quantify N remobilization and the contribution of remobilized N to the grain. A current stay-green commercial hybrid was grown at three fertilizer N rates and infused with 30 mL 15N solution [35.7 mmol N as 15NH(4)15NO(3) at 99.2 15N% atom enrichment (a.e.)] into the internode below the primary cob at anthesis. The control plants were infused with distilled water. Sampling occurred at 3 d, 2 wk and 5 wk after anthesis and at physiological maturity

  1. Desflurane reinforces the efficacy of propofol target-controlled infusion in patients undergoing laparoscopic cholecystectomy

    Directory of Open Access Journals (Sweden)

    Po-Nien Chen

    2016-01-01

    Full Text Available Whether low-concentration desflurane reinforces propofol-based intravenous anesthesia on maintenance of anesthesia for patients undergoing laparoscopic cholecystectomy is to be determined. The aim of this study was to investigate whether propofol-based anesthesia adding low-concentration desflurane is feasible for laparoscopic cholecystectomy. Fifty-two patients undergoing laparoscopic cholecystectomy were enrolled in the prospective, randomized, clinical trial. Induction of anesthesia was achieved in all patients with fentanyl 2 μg/kg, lidocaine 1 mg/kg, propofol 2 mg/kg, and rocuronium 0.8 mg/kg to facilitate tracheal intubation and to initiate propofol target-controlled infusion (TCI to effect site concentration (Ce: 4 μg/mL with infusion rate 400 mL/h. The patients were then allocated into either propofol TCI based (group P or propofol TCI adding low-concentration desflurane (group PD for maintenance of anesthesia. The peri-anesthesia hemodynamic responses to stimuli were measured. The perioperative psychomotor test included p-deletion test, minus calculation, orientation, and alert/sedation scales. Group PD showed stable hemodynamic responses at CO2 inflation, initial 15 minutes of operation, and recovery from general anesthesia as compared with group P. There is no significant difference between the groups in operation time and anesthesia time, perioperative psychomotor functional tests, postoperative vomiting, and pain score. Based on our findings, the anesthetic technique combination propofol and desflurane for the maintenance of general anesthesia for laparoscopic cholecystectomy provided more stable hemodynamic responses than propofol alone. The combined regimen is recommended for patients undergoing laparoscopic cholecystectomy.

  2. An improved efficiency of fuzzy sliding mode control of permanent magnet synchronous motor for wind turbine generator pumping system

    International Nuclear Information System (INIS)

    Benchabane, F.; Titaouine, A.; Guettaf, A.; Yahia, K.; Taibi, D.; Bennis, O.

    2012-01-01

    This paper presents an analysis by which the dynamic performances of a permanent magnet synchronous motor (PMSM) motor is controlled through a hysteresis current loop and an outer speed loop with different controllers. The dynamics of the wind turbine pumping drive system with (PI) and a fuzzy sliding mode (FSM) speed controllers are presented. In order to optimize the overall system efficiency, a maximum power point tracker is also used. Simulation is carried out by formatting the mathematical model for wind turbine generator, motor and pump load. The results for such complicated and nonlinear system, with fuzzy sliding mode speed controller show improvement in transient response of the PMSM drive over conventional PI. The effectiveness of the FSM controller is also demonstrated. (author)

  3. The feasibility of inducing mild therapeutic hypothermia after cardiac resuscitation using iced saline infusion via an intraosseous needle.

    Science.gov (United States)

    Mader, Timothy J; Walterscheid, Joshua K; Kellogg, Adam R; Lodding, Cynthia C

    2010-01-01

    This study was done, using a swine model of prolonged ventricular fibrillation out-of-hospital cardiac arrest, to determine the feasibility of inducing therapeutic hypothermia after successful resuscitation by giving an intraosseous infusion of iced saline. This study was IACUC approved. Liter bags of normal saline, after being refrigerated for at least 24h, were placed in an ice filled cooler. Female Yorkshire swine weighing between 27 and 35 kg were sedated and instrumented under general anesthesia. A temperature probe was inserted 10 cm into the esophagus. Ventricular fibrillation was electrically induced and allowed to continue untreated for 10 min. Animals were randomized to one of two resuscitation schemes for the primary study (N=53). One group had central intravenous access for drug delivery and the other had an intraosseous needle inserted into the proximal tibia for drug administration. Animals in which spontaneous circulation was restored were immediately cooled, for this secondary study, by means of a rapid, pump-assisted infusion of 1L of iced saline either through the intraosseous needle (n=8), the central access (n=6), or a peripheral intravenous catheter (n=7) in a systematic, non-randomized fashion. Room, animal, and saline temperatures were recorded at initiation and upon completion of infusion. The data were analyzed descriptively using Stata SE v8.1 for Macintosh. The baseline characteristics of all three groups were mathematically the same. The average ambient room temperature during the experimental sessions was 25.5 degrees C (SD=1.3 degrees C). There were no statistically significant differences between the three groups with regard to saline temperature, rate of infusion, or decrease in core body temperature. The decrease in core temperature for the intraosseous group was 2.8 degrees C (95% CI=1.8, 3.8) over the infusion period. Mild therapeutic hypothermia can be effectively induced in swine after successful resuscitation of prolonged

  4. Tretinoin microsphere gel 0.04% pump for treating acne vulgaris in preadolescents: a randomized, controlled study.

    Science.gov (United States)

    Eichenfield, Lawrence F; Hebert, Adelaide A; Schachner, Lawrence; Paller, Amy S; Rossi, Ana Beatris; Lucky, Anne W

    2012-01-01

    Although acne vulgaris is common in preadolescents (TMG) 0.04% pump in children aged 9-11 with acne vulgaris. In this multicenter, randomized, double-blind, vehicle-controlled pilot study, patients applied TMG 0.04% pump or vehicle once daily to the face for 12 weeks. Efficacy measures were changes in facial lesion counts, Investigator Global Evaluation of acne severity using two scales, and Investigator Global Assessment of Improvement from baseline to week 12. Of the 110 patients enrolled, 55 received TMG 0.04% pump, and 55 received vehicle. At week 12, there was significantly greater improvement in the least-squares mean change in noninflammatory lesions with TMG 0.04% than with vehicle (-19.9 vs -9.7, p = 0.04) and a significant difference in Investigator Global Assessment of improvement at week 12 between the children treated with TMG 0.04% pump and those treated with vehicle (p = 0.02), but there were no discernible differences in static acne severity scales. Change from baseline in signs and symptoms of cutaneous irritation were similar between the active and vehicle arms at week 12. This study demonstrated statistically significant differences in the reduction of noninflammatory lesions between TMG 0.04% pump and vehicle in patients aged 9-11 with acne vulgaris. Additional studies are warranted to further characterize the safety and efficacy of TMG 0.04% pump for the treatment of acne in the preadolescent population. © 2012 Wiley Periodicals, Inc.

  5. Effect of non-condensable gas on heat transfer in steam turbine condenser and modelling of ejector pump system by controlling the gas extraction rate through extraction tubes

    International Nuclear Information System (INIS)

    Strušnik, Dušan; Golob, Marjan; Avsec, Jurij

    2016-01-01

    Graphical abstract: Control of the amount of the pumped gases through extraction tubes. The connecting locations interconnect the extraction tubes for STC gas pumping. The extraction tubes are fitted with 3 control valves to control the amount of the pumped gas depending on the temperature of the pumped gas. The amount of the pumped gas increases through the extraction tubes, where the pumped gases are cooler and decreases, at the same time, through the extraction tubes, where the pumped gases are warmer. As a result, pumping of a larger amount of NCG is ensured and of a smaller amount of CG, given that the NCG concentration is the highest on the colder places. This way, the total amount of the pumped gases from the STC can be reduced, the SEPS operates more efficiently and consumes less energy for its operation. - Highlights: • Impact of non-condensable gas on heat transfer in a steam turbine condenser. • The ejector system is optimised by selecting a Laval nozzle diameter. • Simulation model of the control of the amount of pumped gases through extraction tubes. • Neural network and fuzzy logic systems used to control gas extraction rate. • Simulation model was designed by using real process data from the thermal power plant. - Abstract: The paper describes the impact of non-condensable gas (NCG) on heat transfer in a steam turbine condenser (STC) and modelling of the steam ejector pump system (SEPS) by controlling the gas extraction rate through extraction tubes. The ideal connection points for the NCG extraction from the STC are identified by analysing the impact of the NCG on the heat transfer and measuring the existing system at a thermal power plant in Slovenia. A simulation model is designed using the Matlab software and Simulink, Neural Net Work, Fuzzy Logic and Curve Fitting Toolboxes, to control gas extraction rate through extraction tubes of the gas pumped from the STC, thus optimising the operation of the steam ejector pump system (SEPS). The

  6. Nano-electro-mechanical pump: Giant pumping of water in carbon nanotubes

    Science.gov (United States)

    Farimani, Amir Barati; Heiranian, Mohammad; Aluru, Narayana R.

    2016-05-01

    A fully controllable nano-electro-mechanical device that can pump fluids at nanoscale is proposed. Using molecular dynamics simulations, we show that an applied electric field to an ion@C60 inside a water-filled carbon nanotube can pump water with excellent efficiency. The key physical mechanism governing the fluid pumping is the conversion of electrical energy into hydrodynamic flow with efficiencies as high as 64%. Our results show that water can be compressed up to 7% higher than its bulk value by applying electric fields. High flux of water (up to 13,000 molecules/ns) is obtained by the electro-mechanical, piston-cylinder-like moving mechanism of the ion@C60 in the CNT. This large flux results from the piston-like mechanism, compressibility of water (increase in density of water due to molecular ordering), orienting dipole along the electric field and efficient electrical to mechanical energy conversion. Our findings can pave the way towards efficient energy conversion, pumping of fluids at nanoscale, and drug delivery.

  7. Output characteristics of a series three-port axial piston pump

    Science.gov (United States)

    Zhang, Xiaogang; Quan, Long; Yang, Yang; Wang, Chengbin; Yao, Liwei

    2012-05-01

    Driving a hydraulic cylinder directly by a closed-loop hydraulic pump is currently a key research area in the field of electro-hydraulic control technology, and it is the most direct means to improve the energy efficiency of an electro-hydraulic control system. So far, this technology has been well applied to the pump-controlled symmetric hydraulic cylinder. However, for the differential cylinder that is widely used in hydraulic technology, satisfactory results have not yet been achieved, due to the asymmetric flow constraint. Therefore, based on the principle of the asymmetric valve controlled asymmetric cylinder in valve controlled cylinder technology, an innovative idea for an asymmetric pump controlled asymmetric cylinder is put forward to address this problem. The scheme proposes to transform the oil suction window of the existing axial piston pump into two series windows. When in use, one window is connected to the rod chamber of the hydraulic cylinder and the other is linked with a low-pressure oil tank. This allows the differential cylinders to be directly controlled by changing the displacement or rotation speed of the pumps. Compared with the loop principle of offsetting the area difference of the differential cylinder through hydraulic valve using existing technology, this method may simplify the circuits and increase the energy efficiency of the system. With the software SimulationX, a hydraulic pump simulation model is set up, which examines the movement characteristics of an individual piston and the compressibility of oil, as well as the flow distribution area as it changes with the rotation angle. The pump structure parameters, especially the size of the unloading groove of the valve plate, are determined through digital simulation. All of the components of the series arranged three distribution-window axial piston pump are designed, based on the simulation analysis of the flow pulse characteristics of the pump, and then the prototype pump is made

  8. An alternative arrangement of metered dosing fluid using centrifugal pump

    Science.gov (United States)

    Islam, Md. Arafat; Ehsan, Md.

    2017-06-01

    Positive displacement dosing pumps are extensively used in various types of process industries. They are widely used for metering small flow rates of a dosing fluid into a main flow. High head and low controllable flow rates make these pumps suitable for industrial flow metering applications. However their pulsating flow is not very suitable for proper mixing of fluids and they are relatively more expensive to buy and maintain. Considering such problems, alternative techniques to control the fluid flow from a low cost centrifugal pump is practiced. These include - throttling, variable speed drive, impeller geometry control and bypass control. Variable speed drive and impeller geometry control are comparatively costly and the flow control by throttling is not an energy efficient process. In this study an arrangement of metered dosing flow was developed using a typical low cost centrifugal pump using bypass flow technique. Using bypass flow control technique a wide range of metered dosing flows under a range of heads were attained using fixed pump geometry and drive speed. The bulk flow returning from the system into the main tank ensures better mixing which may eliminate the need of separate agitators. Comparative performance study was made between the bypass flow control arrangement of centrifugal pump and a diaphragm type dosing pump. Similar heads and flow rates were attainable using the bypass control system compared to the diaphragm dosing pump, but using relatively more energy. Geometrical optimization of the centrifugal pump impeller was further carried out to make the bypass flow arrangement more energy efficient. Although both the systems run at low overall efficiencies but the capital cost could be reduced by about 87% compared to the dosing pump. The savings in capital investment and lower maintenance cost very significantly exceeds the relatively higher energy cost of the bypass system. This technique can be used as a cost effective solution for

  9. Pharmacokinetics and toxicology of continuously infused nitroimidazoles

    International Nuclear Information System (INIS)

    Eifel, P.J.; Brown, J.M.

    1984-01-01

    The pharmacokinetics and toxicology of misonidazole (MISO) and SR-2508 given by continuous intraperitoneal infusion were studied in female C 3 H mice. The survival (time to death) of animals receiving continuous infusions of SR-2508 and MISO was compared and related to plasma concentration, rate of infusion and total amount of drug delivered. Brain and plasma concentrations were determined by HPLC. For SR-2508, plasma concentration was directly proportional to the infusion rate. However, as the infusion rate of MISO was doubled, the plasma concentration of MISO increased approximately 6-fold, reflecting a substantial increase in the apparent half-life. The brain/plasma concentration ratio in animals infused for up to 6 days with SR-2508 remained constant, at approximately 0.09. At plasma concentrations of 0.08-1.5 mM, animals receiving SR-2508 survived approximately 3 times as long as animals exposed to a comparable plasma concentration of MISO. Even at the lowest infusion rates employed in this study, the survival of mice receiving SR-2508 was much shorter than would have been predicted if the toxicity of these two drugs were solely related to the integral brain exposure. The low brain/plasma concentration ratio of SR-2508 was maintained throughout long continuous exposures

  10. MONITORING TETESAN INFUS BERBASIS MIKROKONTROLER ATMEGA16

    Directory of Open Access Journals (Sweden)

    Ardiyanto Iqbal Nugroho

    2015-09-01

    Penelitian ini menghasilkan suatu alat monitoring tetesan infus yang dapat memberikan informasi mengenai laju kecepatan tetesan dan kondisi cairan pada infus. Sistem yang secara realtime dimonitoring oleh perawat ini dapat mengurangi permasalahan yang timbul karena kelalaian petugas. Sehingga perawat tidak secara manual dalam mengatur kecepatan tetesan infus dan meningkatkan pelayanan kepada pasien.

  11. Study Protocol. ECSSIT – Elective Caesarean Section Syntocinon® Infusion Trial. A multi-centre randomised controlled trial of oxytocin (Syntocinon® 5 IU bolus and placebo infusion versus oxytocin 5 IU bolus and 40 IU infusion for the control of blood loss at elective caesarean section

    Directory of Open Access Journals (Sweden)

    Montgomery Alan A

    2009-08-01

    Full Text Available Abstract Background Caesarean section is one of the most commonly performed major operations in women throughout the world. Rates are escalating, with studies from the United States of America, the United Kingdom, China and the Republic of Ireland reporting rates between 20% and 25%. Operative morbidity includes haemorrhage, anaemia, blood transfusion and in severe cases, maternal death. The value of routine oxytocics in the third stage of vaginal birth has been well established and it has been assumed that these benefits apply to caesarean delivery as well. A slow bolus dose of oxytocin is recommended following delivery of the baby at caesarean section. Some clinicians use an additional infusion of oxytocin for a further period following the procedure. Intravenous oxytocin has a very short half-life (4–10 minutes therefore the potential advantage of an oxytocin infusion is that it maintains uterine contractility throughout the surgical procedure and immediate postpartum period, when most primary haemorrhages occur. The few trials to date addressing the optimal approach to preventing haemorrhage at caesarean section have been under-powered to evaluate clinically important outcomes. There has been no trial to date comparing the use of an intravenous slow bolus of oxytocin versus an oxytocin bolus and infusion. Methods and design A multi-centre randomised controlled trial is proposed. The study will take place in five large maternity units in Ireland with collaboration between academics and clinicians in the disciplines of obstetrics and anaesthetics. It will involve 2000 women undergoing elective caesarean section after 36 weeks gestation. The main outcome measure will be major haemorrhage (blood loss >1000 ml. A study involving 2000 women will have 80% power to detect a 36% relative change in the risk of major haemorrhage with two-sided 5% alpha. Discussion It is both important and timely that we evaluate the optimal approach to the management

  12. Study Protocol. ECSSIT – Elective Caesarean Section Syntocinon® Infusion Trial. A multi-centre randomised controlled trial of oxytocin (Syntocinon®) 5 IU bolus and placebo infusion versus oxytocin 5 IU bolus and 40 IU infusion for the control of blood loss at elective caesarean section

    Science.gov (United States)

    Murphy, Deirdre J; Carey, Michael; Montgomery, Alan A; Sheehan, Sharon R

    2009-01-01

    Background Caesarean section is one of the most commonly performed major operations in women throughout the world. Rates are escalating, with studies from the United States of America, the United Kingdom, China and the Republic of Ireland reporting rates between 20% and 25%. Operative morbidity includes haemorrhage, anaemia, blood transfusion and in severe cases, maternal death. The value of routine oxytocics in the third stage of vaginal birth has been well established and it has been assumed that these benefits apply to caesarean delivery as well. A slow bolus dose of oxytocin is recommended following delivery of the baby at caesarean section. Some clinicians use an additional infusion of oxytocin for a further period following the procedure. Intravenous oxytocin has a very short half-life (4–10 minutes) therefore the potential advantage of an oxytocin infusion is that it maintains uterine contractility throughout the surgical procedure and immediate postpartum period, when most primary haemorrhages occur. The few trials to date addressing the optimal approach to preventing haemorrhage at caesarean section have been under-powered to evaluate clinically important outcomes. There has been no trial to date comparing the use of an intravenous slow bolus of oxytocin versus an oxytocin bolus and infusion. Methods and design A multi-centre randomised controlled trial is proposed. The study will take place in five large maternity units in Ireland with collaboration between academics and clinicians in the disciplines of obstetrics and anaesthetics. It will involve 2000 women undergoing elective caesarean section after 36 weeks gestation. The main outcome measure will be major haemorrhage (blood loss >1000 ml). A study involving 2000 women will have 80% power to detect a 36% relative change in the risk of major haemorrhage with two-sided 5% alpha. Discussion It is both important and timely that we evaluate the optimal approach to the management of the third stage at

  13. Prospective, randomized, and controlled trial on ketamine infusion during bilateral axillo-breast approach (BABA) robotic or endoscopic thyroidectomy: Effects on postoperative pain and recovery profiles: A consort compliant article.

    Science.gov (United States)

    Kim, Dong-Ho; Choi, June Young; Kim, Byoung-Gook; Hwang, Jin-Young; Park, Seong-Joo; Oh, Ah-Young; Jeon, Young-Tae; Ryu, Jung-Hee

    2016-12-01

    Robotic or endoscopic thyroidectomy using bilateral axillo-breast approach (BABA) is frequently performed for excellent cosmesis. However, postoperative pain is remained as concerns due to the extent tissue dissection and tension during the operation. Ketamine is a noncompetitive N-methyl-D-aspartate (NMDA) receptor antagonist that reduces acute postoperative pain. We evaluated the effects of intraoperative ketamine infusion on postoperative pain control and recovery profiles following BABA robotic or endoscopic thyroidectomy. Fifty-eight adult patients scheduled for BABA robotic or endoscopic thyroidectomy were randomized into a control group (n = 29) and ketamine group (n = 29). Following induction of anesthesia, patients in each group were infused with the same volume of saline or ketamine solution (1 mg/kg bolus, 60 μg/kg/h continuous infusion). Total intravenous anesthesia with propofol and remifentanil was used to induce and maintain anesthesia. Pain scores (101-point numerical rating scale, 0 = no pain, 100 = the worst imaginable pain), the consumption of rescue analgesics, and other postoperative adverse effects were assessed at 1, 6, 24, and 48 hours postoperatively. Patients in the ketamine group reported lower pain scores than those in the control group at 6 hours (30 [30] vs 50 [30]; P = 0.017), 24 hours (20 [10] vs 30 [20]; P ketamine infusion during anesthesia resulted in lower postoperative pain scores following BABA robotic or endoscopic thyroidectomy, with no increase in adverse events.

  14. Feedback control of primary pump using midplane temperature of lower density lock for a PIUS-type reactor

    International Nuclear Information System (INIS)

    Tasaka, Kanji; Haga, Katsuhiro; Tamaki, Masayoshi

    1993-01-01

    A new automatic pump speed control system, using a measurement of the temperature distribution in the lower density lock, is proposed for the PIUS-type reactor. This control system maintains the fluid temperature at the axial center of the lower density lock at the average of the fluid temperatures below and above the lower density lock in order to prevent the poison water from penetrating into the core during normal operation. In a startup test, the effectiveness of this control system to bring the system quickly to the stable state from a very small initial temperature difference between top and bottom of the lower density lock has been confirmed. The effectiveness of the primary pump trip at the limit speed in the control system to shutdown the core power safely in an accident such as a loss-of-feedwater accident with and without the primary loop isolation has also been proved

  15. Flow pumping system for physiological waveforms.

    Science.gov (United States)

    Tsai, William; Savaş, Omer

    2010-02-01

    A pulsatile flow pumping system is developed to replicate flow waveforms with reasonable accuracy for experiments simulating physiological blood flows at numerous points in the body. The system divides the task of flow waveform generation between two pumps: a gear pump generates the mean component and a piston pump generates the oscillatory component. The system is driven by two programmable servo controllers. The frequency response of the system is used to characterize its operation. The system has been successfully tested in vascular flow experiments where sinusoidal, carotid, and coronary flow waveforms are replicated.

  16. The effects of incisional bupivacaine infusions on postoperative ...

    African Journals Online (AJOL)

    Abstract. Background: The aim of this study was to determine opioid requirements and pain intensity scores in patients after a total abdominal hysterectomy (TAH) administered with a bupivacaine infusion for a 30-hour period, and then to compare the data with that of a control group. Method: This was a prospective, parallel, ...

  17. Efficacy of topical chamomile on the incidence of phlebitis due to an amiodarone infusion in coronary care patients: a double-blind, randomized controlled trial.

    Science.gov (United States)

    Sharifi-Ardani, Maryam; Yekefallah, Leili; Asefzadeh, Saeed; Nassiri-Asl, Marjan

    2017-09-01

    Amiodarone is a useful antiarrhythmic drug. Phlebitis, caused by intravenous amiodarone, is common in patients in coronary care units (CCUs). The aim of this study was to evaluate the effect of topical chamomile on the incidence of phlebitis due to the administration of an amiodarone infusion into the peripheral vein. This was a randomized, double-blind clinical trial, conducted on 40 patients (n = 20 per group) in two groups-an intervention group (chamomile ointment) and a control group (lanoline, as a placebo), hospitalized in the CCUs and undergoing an amiodarone infusion into the peripheral vein over 24 h. Following the cannulation and commencement of the infusion, placebo or chamomile ointment was rubbed in, up to 10 cm superior to the catheter and repeated every eight hours for three days. The cannula site was then assessed based on the phlebitis checklist. The incidence and time of occurrence of phlebitis, relative risk, severity of phlebitis were the main outcome measures. Nineteen patients (19/20) in the control group had phlebitis on the first day of the study and one patient (20/20) on the second day. In the intervention group, phlebitis occurred in 13 cases (13/20) on the first day and another two (2/7) was found on the second day. The incidence of phlebitis was significantly different between two groups (P = 0.023). The cumulative incidence of phlebitis in the intervention group (15/20) is significantly later and lower than that in the control group (20/20) during two days (P = 0.008). Two patients in the intervention group did not develop phlebitis at all during the 3-day study. Also, the relative risk of phlebitis in the two groups was 0.68 (P = 0.008 5). A significant difference was not observed with regard to phlebitis severity in both groups. It seems that phlebitis occurred to a lesser extent and at a later time frame in the intervention group compared to control group. Topical chamomile may be effective in decreasing the incidence of phlebitis

  18. Alignment analysis of a vertical sodium pump

    International Nuclear Information System (INIS)

    Gupta, V.K.; Fair, C.E.

    1981-01-01

    With the objective of identifying important alignment features of pumps such as FFTF, HALLAM, EBR II, PNC, PHENIX, and CRBR, alignment of the vertical sodium pump for the Clinch River Breeder Reactor Plant (CRBRP) is investigated. The CRBRP pump includes a flexibly coupled pump shaft and motor shaft, two oil-film tilting-pad hydrodynamic radial bearings in the motor plus a vertical thrust bearing, and two sodium hydrostatic bearings straddling the double-suction centrifugal impeller in the pump. The assembled CRBRP prototype pump shows smooth predictable vibration behavior experienced during water test. An ealier swing check of the pump shaft about the motor shaft hub demonstrated that the pump is relatively insensitive to manufacturing and assembly tolerances, a consequence of close dimensional control and unique alignment features. (orig./GL)

  19. Simultaneous infusion of glutamine and branched-chain amino acids (BCAA) to septic rats does not have more favorable effect on protein synthesis in muscle, liver, and small intestine than separate infusions.

    Science.gov (United States)

    Holecek, Milan; Muthny, Tomas; Kovarik, Miroslav; Sispera, Ludek

    2006-01-01

    Glutamine and branched-chain amino acids (BCAA; valine, leucine, and isoleucine) are used as nutrition supplements in the treatment of proteocatabolic illness. We hypothesized that simultaneous administration of BCAA and glutamine affects protein metabolism more significantly than separate administration. In the present study, we evaluated their effect on protein synthesis in skeletal muscle, liver, and jejunum of septic rats. Twenty-four hours after induction of sepsis by subcutaneous injection of turpentine, the rats were infused for 6 hours with 5 mL of 1.75% glutamine, 1.75% BCAA, 1.75% glutamine+BCAA, or saline solution. The control group consisted of intact rats infused with saline. Protein synthesis was measured at the end of infusion by a "flooding method" with [3,4,5-(3)H]phenylalanine. In turpentine-treated animals, we observed a decrease in glutamine concentration in blood plasma and skeletal muscle, a decrease in BCAA concentration in liver and jejunum, and a decrease in protein synthesis in all tissues. Glutamine or glutamine+BCAA infusion increased glutamine concentration in plasma and muscle and stimulated protein synthesis in the liver. The BCAA infusion enhanced concentrations of BCAA in plasma and tissues, but the effect of BCAA on protein synthesis was insignificant. Synergistic effect of simultaneous infusion of glutamine and BCAA on protein synthesis was not observed. We conclude that glutamine infusion to rats with septic injury may significantly improve impaired protein synthesis in the liver and that there is no synergistic effect of glutamine and BCAA infusion on protein synthesis in skeletal muscle, liver, and jejunum.

  20. Centrifugal Pump Monitoring and Determination of Pump Characteristic Curves Using Experimental and Analytical Solutions

    Directory of Open Access Journals (Sweden)

    Marius Stan

    2018-02-01

    Full Text Available Centrifugal pumps are widely used in the industry, especially in the oil and gas sector for fluids transport. Classically, these are designed to transfer single phase fluids (e.g., water at high flow rates and relatively low pressures when compared with other pump types. As part of their constructive feature, centrifugal pumps rely on seals to prevent air entrapment into the rotor during its normal operation. Although this is a constructive feature, water should pass through the pump inlet even when the inlet manifold is damaged. Modern pumps are integrated in pumping units which consist of a drive (normally electric motor, a transmission (when needed, an electronic package (for monitoring and control, and the pump itself. The unit also has intake and outlet manifolds equipped with valves. Modern systems also include electronic components to measure and monitor pump working parameters such as pressure, temperature, etc. Equipment monitoring devices (vibration sensors, microphones are installed on modern pumping units to help users evaluate the state of the machinery and detect deviations from the normal working condition. This paper addresses the influence of air-water two-phase mixture on the characteristic curve of a centrifugal pump; pump vibration in operation at various flow rates under these conditions; the possibilities of using the results of experimental investigations in the numerical simulations for design and training purposes, and the possibility of using vibration and sound analysis to detect changes in the equipment working condition. Conclusions show that vibration analysis provides accurate information about the pump’s functional state and the pumping process. Moreover, the acoustic emission also enables the evaluation of the pump status, but needs further improvements to better capture and isolate the usable sounds from the environment.

  1. The effect of pump cavitation on the design of the primary pumps for C.F.R

    International Nuclear Information System (INIS)

    Worster, R.C.

    1976-01-01

    In the design appraisal of the sodium pumps for the primary circuit of the proposed 1300 MW(e) CFR it has been recognised that cavitation, its effects and its control, is the outstanding hydraulic design problem. Careful consideration of this problem and of the possible effects of pump cavitation on the performance of other reactor systems has led to the conclusion that it is more prudent at present to specify pumps with zero cavitation at normal full speed operating conditions. Under abnormal operation it may be necessary to reduce the pumps' speed to prevent cavitation in the pumps or associated equipment. The principal reasons for this decision were uncertainties concerning the possibility of erosion due to limited cavitation in sodium and the possibility of pump cavitation noise interfering with acoustic detection of malfunctioning of reactor components or of boiling in the reactor core

  2. Establishing the relationship between an effective audit committee and infusion of a good control environment

    Directory of Open Access Journals (Sweden)

    Zandile Virtue Dlamini

    2017-12-01

    Full Text Available Audit Committees are a vital component of accountability and good governance for any serious organisation and have progressively been perceived as an integral part of modern control structures and control practices in both the public and private sectors. However, Audit Committees can only discharge such gigantic responsibilities in a conducive environment to provide its effective performance of certain key functions in the areas of oversight of risk management, reporting, and internal controls. Nonetheless, the enablement of such conducive environments has become a challenge to many Audit Committees. It is against this background that this study investigates the relationship between an effective audit committee and infusion of a good control environment. The study used structured and unstructured questions to investigate population comprising standing committee members and Audit Committee members. Thus this study made use of a mixed methodology to collect quantitative data as well as reviewing audit documents, such as, the Audit Committee Charter and minutes of meetings in order to ascertain the environment under which such august practices are performed. The outcome concludes that the Audit Committee which was selected for the study has the good working environment.

  3. APIC position paper: Safe injection, infusion, and medication vial practices in health care.

    Science.gov (United States)

    Dolan, Susan A; Arias, Kathleen Meehan; Felizardo, Gwen; Barnes, Sue; Kraska, Susan; Patrick, Marcia; Bumsted, Amelia

    2016-07-01

    The transmission of bloodborne viruses and other microbial pathogens to patients during routine health care procedures continues to occur because of the use of improper injection, infusion, medication vial, and point-of-care testing practices by health care personnel. These unsafe practices occur in various clinical settings and result in unacceptable and devastating events for patients. This document updates the Association for Professionals in Infection Control and Epidemiology 2010 position paper on safe injection, infusion, and medication vial practices in health care. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Infusing PDA technology into nursing education.

    Science.gov (United States)

    White, Ann; Allen, Patricia; Goodwin, Linda; Breckinridge, Daya; Dowell, Jeffery; Garvy, Ryan

    2005-01-01

    Use of the personal digital assistant (PDA) has been infused into the accelerated baccalaureate program at Duke University to help prepare nursing students for professional practice. The authors provide an overview of the use of PDAs in the classroom, laboratory, and clinical setting. Technical aspects of PDA infusion and steps to ensure regulatory compliance are explored. Benefits of PDA use by both faculty and students in the program and challenges met with the infusion of this technology are also described.

  5. Central Control of Heat Pump for Smart Grid Purposes Tested on Single Family Houses

    DEFF Research Database (Denmark)

    Pedersen, Tom S.; Andersen, Palle; Nielsen, Kirsten M.

    2013-01-01

    A challenge in Denmark in the near future is to balance the electrical grid due to a large increase in the renewable energy production mainly from wind turbines. In this work a central control system using heat pumps in single family houses to help balancing the grid is investigated. The central...

  6. An advanced automation system for operation of Sao Paulo pumping stations from TRANSPETRO Master Control Center - CNCO

    Energy Technology Data Exchange (ETDEWEB)

    Corcioli, Mario Sergio; Barreto, Camila Maria Benevenuto [TRANSPETRO, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    Since 2000 the operations of the TRANSPETRO pumping stations in the state of Sao Paulo region began to be transferred from local control centers located at the transfer and storage terminals to the National Operational Control Center (CNCO) of TRANSPETRO, located at the headquarters of the company, in Rio de Janeiro. The proposed paper aims to presenting an overview of the automation system that was developed to enable such pumping stations to be operated from CNCO in a reliable and secure manner, focusing on tools that offer an embedded system alarms completely free of false alarms with automatic determining of the root cause, and also automatic and advanced diagnoses of problems caused by failures of hardware, human error and abnormal conditions of the process, providing the CNCO SCADA system of accurate and quality information that help operators to make decisions. The referred automation system was integrated for the first time to CNCO SCADA system in 2000, for pipeline pumps of Osvat (Sao Sebastiao - Vale do Paraiba pipeline) station at the Sao Sebastiao Terminal - northern coast of Sao Paulo region. (author)

  7. CRBRP sodium circulating pump design evaluation

    International Nuclear Information System (INIS)

    Marrujo, F.; Cook, M.; Manners, L.; Cothran, H.

    1977-12-01

    The following topics are discussed: (1) primary sodium pump design concept; (2) pump level control system; (3) resolution of design problems in stress analysis, dynamics analysis, and mechanical design; (4) model testing; (5) planned performance tests; and (6) fabrication status

  8. Ileal microbiota of growing pigs fed different dietary calcium phosphate levels and phytase content and subjected to ileal pectin infusion.

    Science.gov (United States)

    Metzler-Zebeli, B U; Vahjen, W; Baumgärtel, T; Rodehutscord, M; Mosenthin, R

    2010-01-01

    Two experiments with growing pigs were conducted to determine the effects of dietary P and Ca levels, phytase supplementation, and ileal pectin infusion on changes in bacterial populations in the ileum and on ileal and fecal fermentation patterns. Growing pigs (BW 30.1 +/- 1.3 kg) were fitted with simple T-cannulas at the distal ileum and were fed a low-P corn-soybean meal control diet (3 g of P/kg), or the control diet supplemented with either 15 g of monocalcium phosphate (MCP)/kg (Exp. 1) or 1,000 phytase units of phytase/kg (Exp. 2). Daily infusion treatments consisted of either 60 g of pectin dissolved in 1.8 L of demineralized water or 1.8 L of demineralized water as a control infusion, infused via the ileal cannula. In each experiment, 8 barrows were assigned to 4 dietary treatments according to a double incomplete 4 x 2 Latin square design. The dietary treatments in Exp. 1 were the control diet with water infusion, the control diet with pectin infusion, the MCP diet with water infusion, or the MCP diet with pectin infusion. In Exp. 2, the pigs received the same control treatments as in Exp. 1 and the phytase diet in combination with water or pectin infusion. Gene copy numbers of total bacteria, Lactobacillus spp., Lactobacillus reuteri, Lactobacillus amylovorus/Lactobacillus sobrius, Lactobacillus mucosae, Enterococcus spp., Enterococcus faecium, Enterococcus faecalis, bifidobacteria, the Clostridium coccoides cluster, the Clostridium leptum cluster, the Bacteroides-Prevotella-Porphyrmonas group, and Enterobacteriaceae were determined by quantitative PCR in DNA extracts of ileal digesta. In Exp. 1, addition of MCP reduced ileal gene copy numbers of Enterococcus spp. (P = 0.048), E. faecium (P = 0.015), and the C. leptum cluster (P = 0.028), whereas pectin infusion enhanced (P = 0.008) ileal d-lactate concentration. In Exp. 2, supplemental phytase led to greater ileal gene copy numbers of the C. coccoides (P = 0.041) and C. leptum (P = 0.048) clusters and

  9. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.

    1984-05-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6MW of auxiliary neutral beam heating. Experiments have also been done with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a region may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this Z-mode of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described

  10. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.; California Univ., Los Angeles

    1984-01-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6 MW of auxiliary neutral beam heating. Experiments have also been performed with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scrape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a regime may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this 'Z-mode' of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described. (orig.)

  11. Review of RSG-GAS secondary cooling pump performance

    International Nuclear Information System (INIS)

    Marsahala, Y.B.

    1999-01-01

    The control system of RSG-GAS secondary pump is the study for the operation existence of RSG-GAS secondary pump. The research is about characteristic of the secondary pump and its control system. The measuring of characteristic parameter of secondary cooling pump was being done while the pump running. The pump was loading with capacity 1950 m3/hr. with ambient temperature 28.5 oC. The fault effect of public grid (PLN) such as the fluctuation of both voltage and frequency likes voltage drops (dip). Supply block out that effect of the electric motor performances directly will be analyzed. How far those faults will effect the overall performance of secondary cooling system. Analyzing. Will be done according to the control system was installed. Has be done to find the direct effects of the motor performances against the motor rotation fluctuation which run from 1450 rpm to 1475 rpm. The using of start-delta starting method with delay time about 6 seconds, is enough or not to reduce the inrush starting current also analyzed in this paper. From the research can be obtained that in the steady state condition , the electric motor runs with both power and current are still under tolerances permitted. According to the analyzed data above, it will be consider that the control system of secondary pump would be modified or not. Therefore the analyzed data can show the characteristic curve of the secondary cooling system performance

  12. The Causes and Prevention Measures of Stuck Pump Phenomenon of Rod-pumped Well in CBM Field

    Science.gov (United States)

    Yonggui, Mei

    2018-02-01

    In the process of CBM field exploitation, in order to realize the drainage equipment to work continuous stably, the article pays attention to study and solve the stuck pump problem, and aim of reducing reservoir damage and lowing production costs. Through coal particles stuck pump experiment and sediment composition analysis, we find out five primary cause of stuck pump phenomenon: sand from coal seam, sediment from ground, iron corrosion, iron scrap caused by eccentric wear, coal cake. According to stuck pump mechanism, the article puts forward 8 measures to prevent stuck pump phenomenon, and the measures are focused on technology optimization, operation management and drainage process control. After 7 years production practice, the yearly stuck pump rate has dropped from 8.9% to 1.2%, and the pump inspection period has prolonged 2 times. The experiment result shows that pure coal particles cannot cause stuck pump, but sand, scrap iron, and iron corrosion are the primary cause of stuck pump. The article study and design the new pipe string structure that the bottom of the pipe string is open. This kind of pipe string applied the sedimentation terminal velocity theory to solve the stuck pump phenomenon, and it can be widely used in CBM drainage development.

  13. Effect of intravenous glucose infusion on renal function in normal man and in insulin-dependent diabetics

    DEFF Research Database (Denmark)

    Frandsen, M; Parving, H H; Christiansen, JS

    1981-01-01

    The effect of intravenous glucose infusion on glomerular filtration rate and renal plasma flow (constant infusion technique using 125I-iothalamate and 131I-hippuran) and on urinary excretion of albumin and beta-2-microglobulin were studied in ten normal subjects and seven metabolically well......-controlled insulin-dependent diabetics. Following glucose infusion in normal subjects (n = 10) blood glucose increased from 4.7 +/- 0.1 to 10.9 +/- 0.4 mmol/l (SEM) (p less than or equal to 0.01). Glomerular filtration rate increased from 116 +/- 2 to 123 +/- 3 ml/mi x 1.73 m2 (p less than or equal to 0.01), while...... no change in renal plasma flow was seen - 552 +/- 11 versus 553 +/- 18 ml/min x 1.73 m2. Volume expansion with intravenous saline infusion in six of the normal subjects induced no changes in blood glucose or kidney function. In seven strictly controlled insulin-dependent diabetics, blood glucose values were...

  14. Effect of short-term intralipid infusion on the immune response during low-dose endotoxemia in humans

    DEFF Research Database (Denmark)

    Krogh-Madsen, R.; Plomgaard, P.; Åkerström, Thorbjörn

    2008-01-01

    on the inflammatory response to a low dose of endotoxin. Fourteen healthy male volunteers underwent the following two trials in a randomized crossover design: 1) continuous infusion of 20% Intralipid [0.7 ml.kg(-1).h(-1) (1.54 g/kg)] for 11 h, and 2) infusion of isotonic saline for 11 h (control). In each trial......, heparin was given to activate lipoprotein lipase, and an intravenous bolus of endotoxin (0.1 ng/kg) was given after 6 h of Intralipid/saline infusion. Blood samples and muscle and fat biopsies were obtained before the Intralipid/saline infusion and before as well as after infusion of an endotoxin bolus....... Plasma levels of FFA, triglycerides, and glycerol were markedly increased during the Intralipid infusion. Endotoxin exposure induced an increase in plasma levels of TNF-alpha, IL-6, and neutrophils and further stimulated gene expression of TNF-alpha and IL-6 in both skeletal muscle and adipose tissue...

  15. Infusion phlebitis assessment measures: a systematic review

    OpenAIRE

    Ray-Barruel, Gillian; Polit, Denise F; Murfield, Jenny E; Rickard, Claire M

    2014-01-01

    Rationale, aims and objectives Phlebitis is a common and painful complication of peripheral intravenous cannulation. The aim of this review was to identify the measures used in infusion phlebitis assessment and evaluate evidence regarding their reliability, validity, responsiveness and feasibility. Method We conducted a systematic literature review of the Cochrane library, Ovid MEDLINE and EBSCO CINAHL until September 2013. All English-language studies (randomized controlled trials, prospecti...

  16. Model predictive control to Maintain ATES balance using heat pump

    NARCIS (Netherlands)

    Hoving, J.; Boxem, G.; Zeiler, W.

    2017-01-01

    A rapidly growing amount of sustainable office buildings in the Netherlands is using an Aquifer Thermal Energy Storage (ATES) system. An ATES system uses a well pump to extract cold groundwater for cooling with the use of a heat pump if necessary. An essential condition for optimal ATES operation is

  17. A simulation-based analysis of variable flow pumping in ground source heat pump systems with different types of borehole heat exchangers: A case study

    International Nuclear Information System (INIS)

    Zarrella, Angelo; Emmi, Giuseppe; De Carli, Michele

    2017-01-01

    Highlights: • The work focuses on the variable flow in ground source heat pump systems. • The constant and variable speed circulation pumps in the ground loop are compared. • The constant temperature difference control across the heat pump is studied. • The variable flow affects the energy performance of the heat pump. • The constant temperature difference control offers an attractive energy saving. - Abstract: A simulation model of ground source heat pump systems has been used to investigate to what extent a variable flow of the heat-carrier fluid of the ground loop affects the energy efficiency of the entire system. The model contemporaneously considers the borehole heat exchangers, the heat pump, the building load, and the control strategies for the circulation pumps of the ground loop. A constant speed of the circulation pumps of the ground loop was compared with a variable flow controlled by means of a constant temperature difference across the heat pump on the ground side considering the load profile of an office building located in North Italy. The analysis was carried out for a single U-tube, double U-tube and coaxial pipe heat exchangers. The control strategies adopted to manage the flow rate of the heat-carrier fluid of the ground loop affect both the heat exchange rate of the borehole field and the heat pump’s long-term energy efficiency. The simulations show considerable differences in the system’s seasonal energy efficiency. The constant speed of the circulation pumps leads to the best results as far as the heat pump’s energy performance was concerned, but this advantage was lost because of the greater amount of electrical energy used by the circulation pumps; this, of course, affects the energy efficiency of the entire system. The optimal solution appears then to be a constant temperature difference in the heat-carrier fluid across the heat pump.

  18. Seizure and electroencephalographic changes in the newborn period induced by opiates and corrected by naloxone infusion.

    Science.gov (United States)

    da Silva, O; Alexandrou, D; Knoppert, D; Young, G B

    1999-03-01

    To describe the association between opioid administration in the newborn period and neurologic abnormalities. Case reports of two infants who presented with seizure activity and abnormal electroencephalograms associated with opiate administration, and reversed by naloxone. The first was a preterm infant who developed a burst-suppression pattern on the electroencephalogram while receiving a continuous infusion of morphine and muscle paralysis. Naloxone injection during the electroencephalogram recording reversed the burst-suppression pattern. The second was a term infant receiving fentanyl infusion for pain control following surgery, who presented with motor seizure that was only partially controlled with barbiturates. An abnormal electroencephalogram recording during the opiate infusion improved with naloxone administration. Our observations indicate a potential for neurologic abnormalities, including induction of seizure activity and electroencephalogram abnormalities, suggesting caution when opiates are used for sedation and/or pain control in the newborn period.

  19. Study of brushless fuel pump (improvement of pump and motor parts). 2nd Report. Blushless dendo fuel pump no kento. 2

    Energy Technology Data Exchange (ETDEWEB)

    Mine, K; Takada, S; Tatematsu, M; Takeuchi, H [Aisan Industry Co. Ltd., Aichi (Japan)

    1992-10-01

    A methanol use electrically driven fuel pump was developed as reported in the present report. Mixed fuel of gasoline with alcohol can be handled by a brushless fuel pump which was proposed and improved as reported. The flow rate performance was heightened to 25g/sec by heightening in output power of motor, while the high temperature performance was 17% heightened against the conventional ratio of lowering in flow rate by heightening in vapor jet capacity. Against the corrosiveness of methanol, an in-tank type was applied to the pump, and all its electrically conductive and other mechanical parts were made to be both anti-corrosive and anti-abrasive. It is structurally of a two-stage series turbine type of non-volume form. A sensor method was applied to the motor by confining the miniaturized control circuit of brushless motor in the motor so that the transistor is controlled against the heightening in temperature. The motor is a three-phase half-wave driving motor. Also developed was a fuel supply system which is useful for the mixed fuel covering a range of 100% methanol through 100% gasoline. The present pump is dimensionally interchangeable with the conventional gasoline use one. Its operational life is more than 10000 hours. 3 refs., 17 figs., 1 tab.

  20. Adsorption pump for helium pumping out

    International Nuclear Information System (INIS)

    Donde, A.L.; Semenenko, Yu.E.

    1981-01-01

    Adsorption pump with adsorbent cooling by liquid helium is described. Shuttered shield protecting adsorbent against radiation is cooled with evaporating helium passing along the coil positioned on the shield. The pump is also equipped with primed cylindrical shield, cooled with liquid nitrogen. The nitrogen shield has in the lower part the shuttered shield, on the pump casing there is a valve used for pump pre-burning, and valves for connection to recipient as well. Pumping- out rates are presented at different pressures and temperatures of adsorbent. The pumping-out rate according to air at absorbent cooling with liquid nitrogen constituted 5x10 -4 Pa-3000 l/s, at 2x10 -2 Pa-630 l/s. During the absorbent cooling with liquid hydrogen the pumping-out rate according to air was at 4x10 -4 Pa-580 l/s, at 2x10 -3 Pa-680 l/s, according to hydrogen - at 8x10 -5 Pa-2500 l/s, at 5x10 -3 Pa-4200 l/s. During adsorbent cooling with liquid helium the rate of pumping-out according to hydrogen at 3x10 5 Pa-2400% l/s, at 6x10 3 Pa-1200 l/s, and according to helium at 3.5x10 -5 Pa-2800 l/s, at 4x10 -3 Pa-1150 l/s. The limit vacuum is equal to 1x10 -7 Pa. The volume of the vessel with liquid helium is equal to 3.5 l. Helium consumption is 80 cm 3 /h. Consumption of liquid nitrogen from the shield is 400 cm 3 /h. The limit pressure in the pump is obtained after forevacuum pumping-out (adsorbent regeneration) at 300 K temperature. The pump is made of copper. The pump height together with primed tubes is 800 mm diameter-380 mm [ru