  1. Patient-controlled analgesic infusion pumps.

    Science.gov (United States)

    2001-05-01

    Patient-controlled analgesic (PCA) infusion devices allow patients to self-administer narcotic analgesics within the limits prescribed by the physician. PCA therapy is typically used for postoperative, obstetric, terminally ill, and trauma patients. PCA pumps deliver solutions intravenously, subcutaneously, or epidurally and allow patient activation by means of a pendant button on a cord connected to the pump or a button directly on the pump. We evaluated nine PCA pumps from six suppliers. Three of these pumps are syringe-type, while the others use cassette-based fluid delivery. Because PCA pumps have often been cited as examples of devices that contribute to medical error (the most significant risk connected with PCA infusion is overmedication), the accident resistance of each device weighed heavily in our testing. The pumps we tested exhibit varying levels of performance, resistance to accidents and tampering, and ease of use. We rate six of them Acceptable. While none of the six units stands out as ideal, they meet most of our criteria, and we consider them somewhat better choices than the rest. We rate one other pump Acceptable (with Conditions) because, in one of its operating modes, it has a drawback that could be dangerous to patients; we consider its use acceptable only if the hospital doesn't employ the operating mode in question. Finally, we rate two pumps Not Recommended because they both have a significant number of disadvantages.

  2. Developing a System for Integraded Automatic Control of Mutiple Infusion Pumps : The Multiplex infusion system

    NARCIS (Netherlands)

    Doesburg, Frank

    2013-01-01

    Most errors in ICUs are related to intravenous (IV) therapy. Previous studies suggested that hard to operate infusion pumps and the high cognitive workload for ICU nurses contribute to these errors. Conventional IV therapy requires separate lumens for incompatible IV drugs. This often requires the p

  3. [Incorrect programming of a target controlled infusion pump. Case SENSAR of the trimester].

    Science.gov (United States)

    2014-10-01

    We report the case of a patient who underwent surgical aortic valve replacement. During general anaesthesia maintenance, the patient received a remifentanyl infusion via a target controlled infusion (TCI) system. The infusion pump that was prepared to deliver the infusion showed malfunction at the beginning of the surgery, so it was quickly replaced with a second pump. After a few minutes into the surgery, the patient presented with hypotension refractory to treatment. The remifentanyl syringe also emptied faster than expected. On reviewing the TCI pump, it was found that it was erroneously programmed for propofol instead of remifentanyl, thus the patient had received a very high dose of remifentanyl that was probably the cause of the haemodynamic disturbances. The incident was an error in equipment use, facilitated by hurry, lack of checking of the equipment prior to its use, and the complex and unclear design of the devices' screens. After analysis of this incident, all TCI pumps were reviewed, and all the programs for infrequently used drugs were deleted. Furthermore, 2 pumps were selected for exclusive use in the cardiac surgery theatre, one with propofol-only programming, and the other with remifentanyl-only programming, both clearly marked and situated in fixed places in that theatre. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  4. Understanding Infusion Pumps.

    Science.gov (United States)

    Mandel, Jeff E

    2017-08-30

    Infusion systems are complicated electromechanical systems that are used to deliver anesthetic drugs with moderate precision. Four types of systems are described-gravity feed, in-line piston, peristaltic, and syringe. These systems are subject to a number of failure modes-occlusion, disconnection, siphoning, infiltration, and air bubbles. The relative advantages of the various systems and some of the monitoring capabilities are discussed. A brief example of the use of an infusion system during anesthetic induction is presented. With understanding of the functioning of these systems, users may develop greater comfort.

  5. Insulin pump-associated adverse events are common, but not associated with glycemic control, socio-economic status, or pump/infusion set type.

    Science.gov (United States)

    Ross, P; Gray, A R; Milburn, J; Kumarasamy, I M; Wu, F; Farrand, S; Armishaw, J; Wiltshire, E; Rayns, J; Tomlinson, P; Wheeler, B J

    2016-12-01

    While there have been many outcome-focussed studies examining insulin pump therapy, only a few have looked at potential adverse events (AEs), with none examining the relationship between AEs and pump/infusion set type, ethnicity or socio-economic status. In addition, current data on the incidence and characteristics of pump-associated AEs are confined to one paediatric centre. We aimed to describe the incidence, characteristics and potential predictors of insulin pump-associated AEs in New Zealand adults and children with T1DM. We approached adults and families of children with T1DM on insulin pumps in four main New Zealand centres. Participants completed a questionnaire examining pump-related issues they had experienced in the preceding 12 months. Response rate was 64 % with 174 of 270 eligible people participating in the study. 84 % of subjects reported one or more AEs, with an overall AE incidence of 3.42 per person/year (95 % CI 3.14, 3.73). An event serious enough to require a hospital presentation occurred in 9.8 %, all but one reporting high ketones or diabetic ketoacidosis (DKA). Set/site problems were the AE most commonly reported (by 53 % of respondents), followed by cutaneous complications (43 %) and pump malfunction (38 %). Few predictors of AEs (of any type) were found; however, a negative binomial regression model found that a longer duration of pumping (p = 0.018) and age Insulin pump-associated AEs are very common. However, few variables are predictive of them with no relationships seen with glycaemic control, socio-economic status, pump manufacturer or infusion set type. Based on these findings, AEs should be anticipated in both adults and children, with anticipatory patient education and training recommended for their successful and safe use.

  6. Smart syringe pumps for drug infusion during dental intravenous sedation.

    Science.gov (United States)

    Seo, Kwang-Suk; Lee, Kiyoung

    2016-09-01

    Dentists often sedate patients in order to reduce their dental phobia and stress during dental treatment. Sedatives are administered through various routes such as oral, inhalation, and intravenous routes. Intravenous administration has the advantage of rapid onset of action, predictable duration of action, and easy titration. Typically, midazolam, propofol or dexmedetomidine are used as intravenous sedatives. Administration of these sedatives via infusion by using a syringe pump is more effective and successful than infusing them as a bolus. However, during intravenous infusion of sedatives or opioids using a syringe pump, fatal accidents may occur due to the clinician's carelessness. To prevent such risks, smart syringe pumps have been introduced clinically. They allow clinicians to perform effective sedation by using a computer to control the dose of the drug being infused. To ensure patient safety, various alarm features along with a drug library, which provides drug information and prevents excessive infusion by limiting the dose, have been added to smart pumps. In addition, programmed infusion systems and target-controlled infusion systems have also been developed to enable effective administration of sedatives. Patient-controlled infusion, which allows a patient to control his/her level of sedation through self-infusion, has also been developed. Safer and more successful sedation may be achieved by fully utilizing these new features of the smart pump.

  7. 75 FR 21641 - Infusion Pumps; Public Meeting; Request for Comments

    Science.gov (United States)

    2010-04-26

    ... HUMAN SERVICES Food and Drug Administration Infusion Pumps; Public Meeting; Request for Comments AGENCY... Food and Drug Administration (FDA) is announcing a public meeting regarding external infusion pumps... infusion pump use, to help the agency identify quality assurance strategies to mitigate these problems,...

  8. Determination of 24-hour insulin infusion pattern by an artificial endocrine pancreas for intravenous insulin infusion with a miniature pump

    DEFF Research Database (Denmark)

    Kølendorf, K; Christiansen, J S; Bojsen, J;

    1981-01-01

    UNLABELLED: Intravenous insulin infusion with a glucose controlled insulin infusion system (GCIIS) is known to restore glucose homeostasis. A simpler approach to improve blood glucose regulation is preprogrammed intravenous insulin infusion with portable pumps without sensor-mediated feedback. We...... report a study designed to evaluate whether the preprogrammed insulin infusion pattern to be used in the miniature insulin infusion pump (MIIP) could be optimized by concomitant employment of the GCIIS for blood glucose control. Six juvenile-onset insulin-dependent diabetics (mean age 31 yrs) were...... studied. Mean blood glucose (MBG) was 6.2 mmol/l +/- 0.5 (SD) during glucose controlled infusion and 5.3 +/- 0.6 during the combined MIIP + GCIIS-day. The insulin requirements calculated from the s.c. regimen (56 U +/- 10 SD) were identical to the GCIIS-measured (51 U +/- 14) and to the amounts delivered...

  9. 电脑输液泵控制鼻饲滴速的临床研究%Clinical research in controlling infusion rate during nasal feeding by infusion pump

    Institute of Scientific and Technical Information of China (English)

    严英; 刘玲

    2010-01-01

    目的 研究改进鼻饲的方法,减少腹泻、呕吐等并发症的发生.方法 选择重型颅脑外伤昏迷患者140例,按采用的鼻饲法分为对照组50例,实验组90例.对照组采用传统的鼻饲方法,实验组应用电脑输液泵控制鼻饲滴速,比较2组并发症的发生率.将实验组患者随机分为3组各30例,在营养液及总量相同的情况下,分别维持10,16,18 h,观察各时间段并发症发生率.结果 实验组腹泻、呕吐等并发症的发生率显著低于对照组;实验组在3个时间段中腹泻、呕吐等并发症的发生率比较无明显差异.结论 使用电脑输液泵控制鼻饲滴速,可明显降低腹泻、呕吐等并发症的发生率;鼻饲营养液在电脑输液泵控制下不必维持很长时间.%Objective To investigate and improve the methods of nasal feeding to reduce the occurrence of complication such as diarrhea and vomiting.Methods We separated 140 patients with heavy craniocerebral injury into the control group (50 patients) and the experimental group (90 patients) according to different nasal feeding methods. For the control group traditional method was used. For the experimental group infusion pump was used to control infusion rate. The incidence of complication was compared between two groups. And within experimental group, the same nutrient solutions in respect of type and volume were infused during 10 hours, 16 hours, and 18 hours respectively. The relationship between infusion rate and the occurrence of complication was observed, analyzed and compared to seek for the most suitable enteral nutrition route which incurred the least complication.Results The incidence of diarrhea and vomiting in the experimental group was lower than that of the control group. And there were no significant differences in the occurrence of complication by using infusion pump at three different infusion rates within the experimental group. Conclusions The application of infusion pump in nasal feeding

  10. [Radiotherapy and implantable medical device: example of infusion pumps].

    Science.gov (United States)

    Abrous-Anane, S; Benhassine, S; Lopez, S; Cristina, K; Mazeron, J-J

    2013-12-01

    Indication for radiotherapy is often questioned for patients equipped with implantable medical devices like infusion pumps as the radiation tolerance is poor or not known. We report here on the case of a patient who we treated with pelvic radiotherapy for cervical cancer and who had an infusion pump in iliac fossa. We conducted a series of tests on five identical pumps that insured that the treatment protocol is harmless to the implanted device.

  11. A Review of the Security of Insulin Pump Infusion Systems

    Science.gov (United States)

    Paul, Nathanael; Kohno, Tadayoshi; Klonoff, David C

    2011-01-01

    Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues. PMID:22226278

  12. A Review of the Security of Insulin Pump Infusion Systems

    Energy Technology Data Exchange (ETDEWEB)

    Klonoff, David C. [Mills-Peninsula Health Services; Paul, Nathanael R [ORNL; Kohno, Tadayoshi [University of Washington, Seattle

    2011-01-01

    Insulin therapy has enabled diabetic patients to maintain blood glucose control to lead healthier lives. Today, rather than manually injecting insulin using syringes, a patient can use a device, such as an insulin pump, to programmatically deliver insulin. This allows for more granular insulin delivery while attaining blood glucose control. The insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this paper we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components including the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but we also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues both for now and in the future.

  13. Establishing glycaemic control with continuous subcutaneous insulin infusion in children and adolescents with type 1 diabetes : experience of the PedPump Study in 17 countries

    NARCIS (Netherlands)

    Danne, T.; Battelino, T.; Jarosz-Chobot, P.; Kordonouri, O.; Pankowska, E.; Ludvigsson, J.; Schober, E.; Kaprio, E.; Saukkonen, T.; Nicolino, M.; Tubiana-Rufi, N.; Klinkert, C.; Haberland, H.; Vazeou, A.; Madacsy, L.; Zangen, D.; Cherubini, V.; Rabbone, I.; Toni, S.; de Beaufort, C.; Waarde, W. Bakker-van; van den Berg, N.; Volkov, I.; Barrio, R.; Hanas, R.; Zumsteg, U.; Kuhlmann, B.; Aebi, C.; Schumacher, U.; Gschwend, S.; Hindmarsh, P.; Torres, M.; Shehadeh, N.; Phillip, M.

    2008-01-01

    Aims/hypothesis To assess the use of paediatric continuous subcutaneous infusion (CSII) under real-life conditions by analysing data recorded for up to 90 days and relating them to outcome. Methods Pump programming data from patients aged 0-18 years treated with CSII in 30 centres from 16 European c

  14. Establishing glycaemic control with continuous subcutaneous insulin infusion in children and adolescents with type 1 diabetes : experience of the PedPump Study in 17 countries

    NARCIS (Netherlands)

    Danne, T.; Battelino, T.; Jarosz-Chobot, P.; Kordonouri, O.; Pankowska, E.; Ludvigsson, J.; Schober, E.; Kaprio, E.; Saukkonen, T.; Nicolino, M.; Tubiana-Rufi, N.; Klinkert, C.; Haberland, H.; Vazeou, A.; Madacsy, L.; Zangen, D.; Cherubini, V.; Rabbone, I.; Toni, S.; de Beaufort, C.; Waarde, W. Bakker-van; van den Berg, N.; Volkov, I.; Barrio, R.; Hanas, R.; Zumsteg, U.; Kuhlmann, B.; Aebi, C.; Schumacher, U.; Gschwend, S.; Hindmarsh, P.; Torres, M.; Shehadeh, N.; Phillip, M.

    Aims/hypothesis To assess the use of paediatric continuous subcutaneous infusion (CSII) under real-life conditions by analysing data recorded for up to 90 days and relating them to outcome. Methods Pump programming data from patients aged 0-18 years treated with CSII in 30 centres from 16 European

  15. Review of epinephrine solution use in 400 consecutive cases of burn reconstruction. Are infusion pumps safe?

    Science.gov (United States)

    Maguiña, Pirko; Velez, Mario

    2013-01-01

    Infiltration of diluted epinephrine solutions is often used in reconstructive surgery to produce local vasoconstriction and minimize bleeding. A total of 400 burn reconstruction procedures were performed with the aid of epinephrine solution between July 2008 and July 2011. We used to consider this practice very safe, but after encountering several complications, we decided to perform a retrospective review to look at all complications in detail and identify opportunities to improve safety. We encountered nine complications including one case of flash pulmonary edema and one patient with acute carpal tunnel syndrome. All severe complications were seen when the epinephrine solution was infiltrated with the aid of an electric infusion pump. Infusion pumps do not allow for reliable control of the amount of infiltration of epinephrine solutions. We conclude that infusion pumps may unnecessarily increase the risk for complications. This has resulted in a change in our practice. We now use infusion pumps only in selected cases.

  16. Quantitative assessment of haemolysis secondary to modern infusion pumps.

    Science.gov (United States)

    Poder, T G; Boileau, J-C; Lafrenière, R; Thibault, L; Carrier, N; de Grandmont, M-J; Beauregard, P

    2017-04-01

    Although most studies have shown that little haemolysis is induced by infusion pumps, there are some notable exceptions. Only limited data are available on the actual infusion pumps that are most used in hospitals in Quebec and elsewhere, namely, the Infusomat(®) Space (peristaltic), Plum A+™ (piston) and Colleague(®) CXE (shuttle) pumps. Haemolysis and potassium levels were compared before and after the use of the three different infusion pumps. Using 135 units of packed red blood cells (RBCs) aged from 10 to 28 days, 27 measurements were taken for each pump at various flow rates (30, 60, 150, 300 and 450 ml/h) and were compared with measurements taken before using the pumps. The range of flow rates was chosen to cover those of paediatric and adult transfusions. The shuttle- and piston-type pumps resulted in low haemolysis levels. The peristaltic-type pump produced significantly more haemolysis, which worsened at low flow rates, but the absolute value of haemolysis remained within the range recommended by the regulatory agencies in North America and Europe. Approximately two-thirds of the haemolysis produced by the peristaltic-type pump seemed to be secondary to the use of an antisiphon valve (ASV) on the transfusion line recommended by the manufacturer. Potassium levels did not increase with the use of the pumps. Modern infusion pumps widely used in hospitals in Quebec and elsewhere produce non-threatening levels of haemolysis during the transfusion of packed RBCs aged from 10 to 28 days. ASVs appear to induce additional haemolysis, and we do not recommend using them for blood transfusion. © 2017 International Society of Blood Transfusion.

  17. Infusion of iloprost without a peristaltic pump: Safety and tolerability

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2013-04-01

    Full Text Available Introduction: Iloprost is a potent prostacyclin (PGI2 analogue that is effective in the treatment of peripheral arterial disease, vasculitis, pulmonary hypertension, and secondary Raynaud’s phenomenon. Intravenous infusions are generally administered with the aid of a peristaltic pump to reduce the risk of adverse reactions caused by unintentional increases in the infusion rate. This increases the cost of care in terms of equipment and personnel and may limit the use of this drug. Materials and methods: We retrospectively analyzed 18,432 iloprost infusions administered between 1999 and 2009 to 272 patients with systemic sclerosis (n = 253 and 19 with peripheral arterial disease (n = 19. All infusions were administered in the day hospital over 6 h with a normal IV set-up with a roller flow regulator. Flow rates were set to deliver iloprost at 1-2 ng/kg/min. Rates were verified by direct drop counts during the first 15-20 minutes of the infusion and at each subsequent check. Results: There were no adverse events that were fatal, life-threatening, or associated with prolongation of hospitalization and very few events requiring intensive care or continuous monitoring. The latter included 4 cases of tachycardia/arrhythmia (extrasystoles in most cases, 3 cases of hypotension (systolic pressure < 80 mmHg, and 2 cases of hypertension (BP > 170/100 mmHg. All other adverse reactions were mild, reversible, and similar to those seen with iloprost infusion with peristaltic pump. Only one patient had to be switched to another prostanoid (due to intolerance. Discussion: Iloprost infusion administered with a normal IV flow regulator appears to be as safe, well tolerated, and effective as traditional infusion with a peristaltic pump.

  18. A Hazard Analysis for a Generic Insulin Infusion Pump

    Science.gov (United States)

    Zhang, Yi; Jones, Paul L.; Jetley, Raoul

    2010-01-01

    Background Researchers at the Food and Drug Administration (FDA)/Center for Device and Radiological Health/Office of Science and Engineering Laboratories have been exploring the concept of model-based engineering as a means for improving the quality of medical device software. Insulin pumps were chosen as a research subject because their design provides the desired degree of research complexity and these types of devices present an ongoing regulatory challenge. Methods Insulin pump hazards and their contributing factors are considered in the context of a highly abstract generic insulin infusion pump (GIIP) model. Hazards were identified by consulting with manufacturers, pump users, and clinicians; by reviewing national and international standards and adverse event reports collected by the FDA; and from workshops sponsored by Diabetes Technology Society. This information has been consolidated in tabular form to facilitate further community analysis and discussion. Results A generic insulin infusion pump model architecture has been established. A fairly comprehensive hazard analysis document, corresponding to the GIIP model, is presented in this article. Conclusions We believe that this work represents the genesis of an insulin pump safety reference standard upon which future insulin pump designs can be based to help ensure a basic level of safety. More interaction with the diabetes community is needed to assure the quality of this safety modeling process. PMID:20307387

  19. Home Healthcare Medical Devices: Infusion Therapy - Getting the Most Out of Your Pump

    Science.gov (United States)

    ... Home Healthcare Medical Devices: Infusion Therapy - Getting the Most Out of Your Pump Share Tweet Linkedin Pin ... and accessories schedule routine maintenance What are the most common problems with an infusion pump and how ...

  20. Comparative analytics of infusion pump data across multiple hospital systems.

    Science.gov (United States)

    Catlin, Ann Christine; Malloy, William X; Arthur, Karen J; Gaston, Cindy; Young, James; Fernando, Sudheera; Fernando, Ruchith

    2015-02-15

    A Web-based analytics system for conducting inhouse evaluations and cross-facility comparisons of alert data generated by smart infusion pumps is described. The Infusion Pump Informatics (IPI) project, a collaborative effort led by research scientists at Purdue University, was launched in 2009 to provide advanced analytics and tools for workflow analyses to assist hospitals in determining the significance of smart-pump alerts and reducing nuisance alerts. The IPI system allows facility-specific analyses of alert patterns and trends, as well as cross-facility comparisons of alert data uploaded by more than 55 participating institutions using different types of smart pumps. Tools accessible through the IPI portal include (1) charts displaying aggregated or breakout data on the top drugs associated with alerts, numbers of alerts per device or care area, and override-to-alert ratios, (2) investigative reports that can be used to characterize and analyze pump-programming errors in a variety of ways (e.g., by drug, by infusion type, by time of day), and (3) "drill-down" workflow analytics enabling users to evaluate alert patterns—both internally and in relation to patterns at other hospitals—in a quick and efficient stepwise fashion. The formation of the IPI analytics system to support a community of hospitals has been successful in providing sophisticated tools for member facilities to review, investigate, and efficiently analyze smart-pump alert data, not only within a member facility but also across other member facilities, to further enhance smart pump drug library design. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  1. 输液泵控制换血术治疗新生儿重症黄疸的护理研究%Nursing of Infusion Pump Control Transfusion in Treating Severe Neonatal Jaundice

    Institute of Scientific and Technical Information of China (English)

    耿洪维

    2016-01-01

    目的:探讨输液泵控制换血术治疗新生儿重症黄疸的护理效果。方法将68例新生儿重症黄疸患儿随机分为对照组和研究组,各34例,两组均接受输液泵控制换血术治疗,对照组应用常规护理,研究组应用综合护理,比较两组护理效果。结果两组患者临床治疗护理效果比较,研究组高于对照组,差异具有统计学意义(P<0.05)。结论应用输液泵控制换血术治疗新生儿重症黄疸能够取得显著的效果,配合综合护理有助于提高治疗效果。%Objective To investigate the nursing effect of infusion pump controlled exchange transfusion for treatment of neonatal severe jaundice. Methods 68 cases of neonatal severe jaundice patients were randomly assigned to study group and control group, 34 cases in each group, two groups underwent infusion pump control exchange transfusion for treatment, the control group used routine nursing, the research group was treated with comprehensive nursing, compared two groups of nursing effect. Results Two groups of patients with clinical treatment effect comparison, the study group was significantly higher than the control group, the difference was statistically significant (P<0.05).Conclusion By infusion pump control exchange transfusion in treating severe neonatal jaundice can achieve significant results, with comprehensive nursing is helpful to improve the therapeutic effect.

  2. Haemolysis following rapid experimental red blood cell transfusion--an evaluation of two infusion pumps

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; Sprogøe-Jakobsen, U; Pedersen, C M;

    1998-01-01

    The vast majority of infusion pumps used for rapid transfusion of large amounts of blood have never been properly examined regarding their influence on the quality of the red blood cells (RBCs) infused. In this study, we evaluated the effect of two different infusion pumps on the degree of RBC...

  3. Haemolysis following rapid experimental red blood cell transfusion--an evaluation of two infusion pumps

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; Sprogøe-Jakobsen, U; Pedersen, C M

    1998-01-01

    The vast majority of infusion pumps used for rapid transfusion of large amounts of blood have never been properly examined regarding their influence on the quality of the red blood cells (RBCs) infused. In this study, we evaluated the effect of two different infusion pumps on the degree of RBC de...

  4. User preference for a portable syringe pump for iloprost infusion

    Directory of Open Access Journals (Sweden)

    Laria A

    2015-05-01

    Full Text Available Antonella Laria,1 Alfredo Maria Lurati,1 Katia Angela Re,1 Maria Grazia Marrazza,1 Daniela Mazzocchi,1 Alberto Farina,2 Magda Scarpellini,1 1Department of Rheumatology, Fornaroli Hospital, Magenta, Milan, Italy; 2Medical Affairs Department, Italfarmaco S.p.A., Cinisello Balsamo, Milan, Italy Purpose: Administration of intravenous iloprost – a first-line European League Against Rheumatism (EULAR-recommended choice for the treatment of scleroderma (SSc-related digital vasculopathy – requires repeated treatment cycles of 6 hours per day in a hospital setting. During the infusion, patient mobility is considerably restricted due to the size and fixity of traditional syringe pumps. The aim of this study was to evaluate the satisfaction level of patients and nurses, after the introduction of a new portable syringe pump (Infonde®, Italfarmaco S.p.A., Milan, Italy at the Department of Rheumatology, Magenta Hospital, Milan, Italy. Patients and methods: Thirty-four consecutive SSc patients receiving stable therapy with iloprost, previously administered with a fixed pump, were treated using the portable Infonde® pump. Patients (n=34 and nurses (n=4 were asked to answer a nine- and six-item questionnaire, respectively, to assess the satisfaction of the administration comparing the new device versus the previous one. The health care staff of the ward developed the questionnaire, and the response scores ranged from 0 (fixed device better to 10 (portable device better; thus a score >5 indicates a preference for Infonde®. Results: Patients' answers indicated a preference towards the new portable syringe pump, versus the previous fixed pump. Questionnaires administered to patients generated a total of 306 responses, with over 95% of the responses in the range 8–10, of which 89% had a score equal to 10. The responses of nurses showed a score equal to 10 in 100% cases. No significant adverse events were recorded, indicating no change in the tolerability

  5. In vitro evaluation of hydraulic characteristics of prototype implantable intrathecal infusion pump.

    Science.gov (United States)

    Nam, Kyoung Won; Sung, Mun Hyun; Kim, Hyun Ho; Kim, Kwang Gi; Kim, Dae Hyun; Lee, Byeong Han; Jo, Yung Ho

    2010-12-01

    The use of the intrathecal infusion pump for therapeutic treatment and pain management is increasing. For example, one such application is the pain treatment of cancer patients suffering from severe chronic pain, where all other treatment methods have failed. This method is gaining popularity because of its high cure effect with low dosage. In this study, we developed a prototype implantable intrathecal infusion pump and evaluated its mechanical and hydraulic characteristics in vitro to determine how its performance varied under different environmental conditions. The data are reported as means (standard deviations). In the experiments, the prototype pump could control the micro-scale infusion amount, and its performance was affected by ambient temperature and pressure conditions. In a temperature change test, at a constant pressure of 1.0 atm, the minimal amounts of a bolus were 4.44 (1.07), 5.06 (1.17), and 5.54 (0.90) uL for the temperature of 27.5, 36.5, and 42°C, respectively. In a pressure change test, at a constant temperature of 36.5°C, the minimal amounts of a bolus were 5.06 (1.17), 5.94 (0.67), and 6.13 (0.39) uL for pressures of 1.0, 0.9 and 0.8 atm, respectively. These experimental results demonstrate the possibility of using the prototype pump as an implantable microvolumetric infusion device. However, this prototype pump will have to undergo further design enhancement before being clinically feasible for such an application.

  6. Assessment of implantable infusion pumps for continuous infusion of human insulin in rats: potential for group housing

    DEFF Research Database (Denmark)

    Jensen, Vivi Flou Hjorth; Molck, Anne-Marie; Martensson, Martin

    2017-01-01

    compound in these studies, and a comparator model of persistent exposure by HI infusion from external pumps has recently been developed to support toxicological evaluation of long-acting insulin analogues. However, this model requires single housing of the animals. Developing an insulin-infusion model......Group housing is considered to be important for rats, which are highly sociable animals. Single housing may impact behaviour and levels of circulating stress hormones. Rats are typically used in the toxicological evaluation of insulin analogues. Human insulin (HI) is frequently used as a reference...... which allows group housing would therefore greatly improve animal welfare. The aim of the present study was to investigate the suitability of implantable infusion pumps for HI infusion in group-housed rats. Group housing of rats implanted with a battery-driven pump proved to be possible. Intravenous...

  7. Development of an implantable infusion pump for sustained anti-HIV drug administration.

    Science.gov (United States)

    Baert, Lieven; Schueller, Laurent; Tardy, Yanik; Macbride, Doug; Klooster, Gerben van't; Borghys, Herman; Clessens, Ellen; Van Den Mooter, Guy; Van Gyseghem, Elke; Van Remoortere, Pieter; Wigerinck, Piet; Rosier, Jan

    2008-05-01

    Factors such as insufficient drug potency, non-compliance and restricted tissue penetration contribute to incomplete suppression of Human Immunodeficiency Virus (HIV) and the difficulty to control this infection. Infusion via standard catheters can be a source of infection, which is potentially life threatening in these patients. We developed an implantable infusion pump, allowing to accommodate large volumes (16-50mL) of high viscous solutions (up to 23.96mPas at 39 degrees C) of anti-HIV agents and providing sustained release of medication: a standard Codman 3000 pump, which was initially developed to release aqueous solutions ( approximately 0.7mPas) into the spinal cord such as for pain medication, was transformed for release of viscous solutions up to 40mPas by adapting the diameter of the capillary flow restrictor, the capillary length and way of catheterisation--by placing the indwelling catheter in the vena cava. A pilot study of the pump implanted in 2 dogs showed continuous steady-state release of the protease inhibitor darunavir (25mg/dog/day administered for 25 days), thereby achieving plasma concentration levels of approximately 40ng/mL. Steady-state plasma levels were reproducible after monthly refill of the pumps. In conclusion, the implantable adapted Codman 3000 constant-flow infusion pump customized to anti-HIV therapy allows sustained release of anti-HIV medication and may represent an opportunity to reduce the pill burden and complexity of dosing schemes associated with common anti-HIV therapy.

  8. The History of Target-Controlled Infusion

    NARCIS (Netherlands)

    Struys, Michel M. R. F.; De Smet, Tom; Glen, John (Iain) B.; Vereecke, Hugo E. M.; Absalom, Anthony R.; Schnider, Thomas W.

    Target-controlled infusion (TCI) is a technique of infusing IV drugs to achieve a user-defined predicted (target) drug concentration in a specific body compartment or tissue of interest. In this review, we describe the pharmacokinetic principles of TCI, the development of TCI systems, and technical

  9. Graphical user interface simplifies infusion pump programming and enhances the ability to detect pump-related faults.

    Science.gov (United States)

    Syroid, Noah; Liu, David; Albert, Robert; Agutter, James; Egan, Talmage D; Pace, Nathan L; Johnson, Ken B; Dowdle, Michael R; Pulsipher, Daniel; Westenskow, Dwayne R

    2012-11-01

    Drug administration errors are frequent and are often associated with the misuse of IV infusion pumps. One source of these errors may be the infusion pump's user interface. We used failure modes-and-effects analyses to identify programming errors and to guide the design of a new syringe pump user interface. We designed the new user interface to clearly show the pump's operating state simultaneously in more than 1 monitoring location. We evaluated anesthesia residents in laboratory and simulated environments on programming accuracy and error detection between the new user interface and the user interface of a commercially available infusion pump. With the new user interface, we observed the number of programming errors reduced by 81%, the number of keystrokes per task reduced from 9.2 ± 5.0 to 7.5 ± 5.5 (mean ± SD), the time required per task reduced from 18.1 ± 14.1 seconds to 10.9 ± 9.5 seconds and significantly less perceived workload. Residents detected 38 of 70 (54%) of the events with the new user interface and 37 of 70 (53%) with the existing user interface, despite no experience with the new user interface and extensive experience with the existing interface. The number of programming errors and workload were reduced partly because it took less time and fewer keystrokes to program the pump when using the new user interface. Despite minimal training, residents quickly identified preexisting infusion pump problems with the new user interface. Intuitive and easy-to-program infusion pump interfaces may reduce drug administration errors and infusion pump-related adverse events.

  10. Clinical safety of magnetic resonance imaging in patients with implanted SynchroMed EL infusion pumps

    Energy Technology Data Exchange (ETDEWEB)

    Diehn, Felix E.; Wood, Christopher P.; Watson, Robert E.; Hunt, Christopher H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Mauck, William D. [Mayo Clinic, Department of Anesthesiology, Rochester, MN (United States); Burke, Michelle M. [Mayo Clinic, Department of Psychiatry and Psychology, Rochester, MN (United States)

    2011-02-15

    Patients with implanted SynchroMed spinal infusion pumps (Medtronic, Inc., Minneapolis, MN) routinely undergo magnetic resonance imaging at our institution. In August 2008, Medtronic issued an urgent medical device correction report regarding several pumps. Because of the rare potential ''for a delay in the return of proper drug infusion'' and ''for a delay in the logging of motor stall events,'' ''a patient's pump must be interrogated after MRI exposure in order to confirm proper pump functionality.'' This is particularly important in patients receiving intrathecal baclofen, for whom a delay in return of proper pump infusion could lead to life-threatening baclofen withdrawal syndrome. The objective of this report is to present our experience and protocol of performing magnetic resonance imaging in patients with implanted SynchroMed EL pumps. We retrospectively reviewed records of 86 patients with implanted SynchroMed EL spinal infusion pumps who underwent 112 examinations on 1.5-T magnetic resonance imaging scanners from September 1, 1998 to July 7, 2004. No SynchroMed EL pumps were damaged by magnetic resonance imaging, and the programmable settings remained unchanged in all patients. Our data suggest that SynchroMed EL pump malfunction is indeed rare after routine clinical 1.5-T magnetic resonance imaging examinations. However, based on the Medtronic correction report, we perform pump interrogation before and after imaging. (orig.)

  11. Use of an oil-hydraulic microinjection pump for subretinal infusions.

    Science.gov (United States)

    Weichel, Judith; Valtink, Monika; Engelmann, Katrin; Richard, Gisbert

    2002-01-01

    The injection of cell suspensions or drugs into the subretinal space is a new promising option of vitreoretinal surgery for the treatment of degenerative retinal disorders. We used a manual oil-hydraulic microinjection pump to subretinally inject suspensions of retinal pigment epithelial cells in Royal College of Surgeons rats and in patients suffering from age-related macular degeneration with geographic atrophy. The histological examination of the treated rat eyes showed that cell suspensions could be placed precisely in the subretinal space. Intra- and postoperative outcome of the patients in the clinical trial revealed no retinal complications during 6 months of follow up. We suggest the oil-hydraulic microinjection pump to be a valuable instrument for controlled and precisely dosed atraumatic infusion or aspiration of small volumes of cell suspensions, fluids or drugs in vitreoretinal surgery.

  12. The History of Target-Controlled Infusion.

    Science.gov (United States)

    Struys, Michel M R F; De Smet, Tom; Glen, John Iain B; Vereecke, Hugo E M; Absalom, Anthony R; Schnider, Thomas W

    2016-01-01

    Target-controlled infusion (TCI) is a technique of infusing IV drugs to achieve a user-defined predicted ("target") drug concentration in a specific body compartment or tissue of interest. In this review, we describe the pharmacokinetic principles of TCI, the development of TCI systems, and technical and regulatory issues addressed in prototype development. We also describe the launch of the current clinically available systems.

  13. Review of pharmacokinetic models for target controlled infusions in anesthesia

    Directory of Open Access Journals (Sweden)

    Subash Kennedy Sivasubramaniam

    2014-06-01

    Full Text Available Intravenous injection of anesthetic drugs dates back to the 17th Century when opium and chloral hydrate have been injected intravenously. It was not until the 1930s intravenous anesthesia became popular with the invention of barbiturates.Early intravenous anesthetic agents such as barbiturates were ideal for induction of anesthesia, but not suitable for maintenance of anesthesia. Most of these drugs accumulated significantly with increasing durations of infusion and also resulted in cardiorespiratory depression. The invention of propofol and shorter acting opioid analgesics such as remifentanil and alfentanil have revolutionized intravenous anesthesia. The rapid onset and offset of these drugs lends itself to being suitable agents for maintenance of anesthesia over prolonged periods of time. Detailed understanding of the pharmacokinetics of propofol and remifentanil, combined with technological advances in intravenous pumps capable of accurate delivery of drugs have resulted in great development of the field of total intravenous anesthesia and target controlled infusions. I would like to discuss, in this article, the pharmacokinetics and pharmacokinetic models behind these intravenous infusion pumps. [Int J Basic Clin Pharmacol 2014; 3(3.000: 417-423

  14. User experience network. Erroneous downstream occlusion alarms may disable Smiths Medical CADD-Solis infusion pumps.

    Science.gov (United States)

    2010-10-01

    Due to an issue in manufacturing, downstream occlusion (DSO) sensors in some Smiths Medical CADD-Solis infusion pumps may drift out of calibration, potentially resulting in erroneous alarms that disable the units. Hospitals experiencing the problem should return affected units to Smiths Medical for recalibration (free of charge) and should consider testing all their CADD-Solis pumps during routine maintenance to ensure that they alarm appropriately for downstream occlusions.

  15. In vitro viability effects on apheresis and buffy-coat derived platelets administered through infusion pumps

    Directory of Open Access Journals (Sweden)

    Sandgren P

    2014-12-01

    Full Text Available Per Sandgren,1,2 Veronica Berggren,3 Carl Westling,1,2 Viveka Stiller1 1Department of Clinical Immunology and Transfusion Medicine, Karolinska University Hospital, 2Department of Laboratory Medicine, Karolinska Institutet, 3Department of Neonatology, Karolinska University Hospital, Stockholm, SwedenBackground: Different infusion pump systems as well as gravity infusion have been widely used in neonatal transfusion. However, the limited number of published studies describing the use of infusion pumps on platelets illustrates the necessity for more robust data.Methods: To evaluate the potential in vitro effects on the cellular, metabolic, functional and phenotypic properties of platelets, we set up a four-arm paired study simultaneously comparing the use of different infusion pumps (Alaris® CC/GP with unexposed platelets. The platelet units (n=8 were either produced by the apheresis technique and suspended in 100% plasma or derived from buffy coats to yield platelet units stored in approximately 30% plasma and 70% SSP+. Fresh and 5-day old platelets were tested.Results: Regardless of the production system or storage time used, no significant differences were observed in glucose and lactate concentration, pH, adenosine triphosphate levels, response to extent of shape change, hypotonic shock response reactivity, and CD62P expression. Similarly, no differences were observed in expression of the conformational epitope on glycoprotein IIb/IIIa, determined using procaspase-activating compound 1, or in the expression of CD42b and platelet-endothelial cell adhesion molecule-1 in a comparison between platelets administered through infusion pumps versus unexposed platelets.Conclusion: Using Alaris CC/GP infusion pumps had no influence on the cellular, functional, and phenotypic in vitro properties of platelets. This fact seems not to be affected by different production systems or storage time.Keywords: platelets, neonatal platelet transfusion

  16. Platelet transfusion in chemotherapy patients: comparison of the effect of intravenous infusion pumps versus gravity transfusion.

    Science.gov (United States)

    Meess, A

    2015-01-01

    Platelet concentrates are given to patients suffering with severe thrombocytopenia usually by a gravity transfusion procedure. Increasing patient numbers that are in need of this treatment increase the pressure on hospital staff and space. In order to combat time issues, the use of medical devices such as intravenous infusion pumps are thought to be beneficial for time and simultaneously for safety in transfusion practices. By using infusion pumps, platelet concentrates can be transfused in less time and provide accurate volume measurements. Manufacturers of infusion pumps claim that these devices are safe to be used for blood products including platelet concentrates. However, published studies were performed on older models and newer devices are on the market now. The purpose of this study is to evaluate infusion pumps, which are claimed to be suitable for blood products and to investigate the impact the pumps had on platelets. Furthermore, the study revealed if the intravenous infusion pumps are safe to be used for platelet transfusion as claimed by manufacturers. A simulated transfusion was performed using the Carefusion Alaris GP Plus volumetric pump and Fresenius Kabi Volumat Agilia infusion pump. Samples were taken from expired platelet concentrates before and after passage through the pump. All samples were investigated for full blood count that included platelet count, mean platelet volume (MPV), platelet distribution width (PDW) and a plateletcrit (PCT). The samples were then centrifuged to achieve platelet-poor plasma and then tested for lactate dehydrogenase (LDH). A power calculation performed on the statistical power analysis program G*power indicated a requirement of 82 samples for a power of 80%. Statistical analysis was performed with the IBM SPSS statistic software. A paired sample t-test was used to calculate mean, standard deviation and P values for the infusion pumps used. The Wilcoxon Signed Rank Test was used to evaluate results that had a non

  17. Efeito da bomba de infusão de soluções sobre o grau de hemólise em concentrados de hemácias Effect of the infusion pumps of solutions on the degree of hemolysis

    Directory of Open Access Journals (Sweden)

    Eunice B. Carvalho

    2007-06-01

    mechanical trauma due to the use of different models of infusion pumps, on red blood cells transfused after up to ten days of storage. Three models of pumps were studied (Nutrimat, Infusomat Compact and Volumed, (four devices of each model with three infusion speeds being tested (120 mL/h, 240 mL/h and 360 mL/h. The parameters used to report the degree of hemolysis were the percentile of hemolysis, hemoglobin levels and free potassium in the plasma. Samples were collected before infusion of red blood cells using the pumps, half way through infusion (1/2 T and at the end of infusion (T, for the three different speeds. Significant variations were not seen in the analyzed parameters between the control samples and those collected at different speeds, using different models of pumps and infusion mechanisms and among pumps of the same brand and at different infusion times. The greatest variation found involved free potassium, probably due to the different levels found in red blood cell concentrates seen when control samples were compared to values obtained half way through and at the end of infusion for each pump. In agreement with the obtained results changes in the percentile of hemolysis were not found after infusion of the cells using the different infusion pumps.

  18. Security risk of medical devices in IT networks: the case of an infusion and infusion syringe pump

    Science.gov (United States)

    Knackmuß, Jenny; Möller, Thomas; Pommerien, Wilfried; Creutzburg, Reiner

    2015-03-01

    Nowadays, wearable and implantable medical devices are being increasingly deployed to improve diagnosis, monitoring, and therapy for various medical conditions. Compared to other types of electronics and computing systems, security attacks on these medical devices have extreme consequences and must be carefully analyzed and prevented with strongest efforts. Often, the security vulnerabilities of such systems are not well understood or underestimated. The aim of this paper is to demonstrate security attacks that can easily be done in the laboratory on a popular infusion pump on the market, and also propose defenses against such attacks.

  19. Iloprost infusion by a new device as a portable syringe pump: safety, tolerability and agreement

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2012-12-01

    Full Text Available Background Iloprost, prostacyclin (PGI2 analogue, effective in treatment of peripheral arterial disease, secondary Raynaud's phenomenon (RP to connective tissue disease (CTD, vasculitis, pulmonary hypertension, is usually infused through peristaltic pump, or recently through a flow regulator.Materials and methods We tested a new portable syringe pump (Pompa Infonde®, Italfarmaco S.p.A., Cinisello Balsamo, Milano on 120 patients affected by RP to CTD and cryoglobulinaemia, in iloprost therapy with a flow regulator.Results Iloprost infused through portable syringe pump is better tolerated, better appreciated by the patients and nurses and no difference was observed on therapeutic effects, with a lower incidence of side effects statistically significant. Only 3 patients were unable to tolerate the device (2 for changes in pressure and 1 for fear and shifted to traditional method of iloprost infusion.Conclusions Iloprost infusion through the portable syringe Pompa Infonde® appears to be safe, better tolerated, more acceptable and equally effective compared to infusion through a flow regulator.

  20. Impact of Computerized Order Entry to Pharmacy Interface on Order-Infusion Pump Discrepancies

    Directory of Open Access Journals (Sweden)

    Rebecca A. Russell

    2015-01-01

    Full Text Available Background. The ability of safety technologies to decrease errors, harm, and risk to patients has yet to be demonstrated consistently. Objective. To compare discrepancies between medication and intravenous fluid (IVF orders and bedside infusion pump settings within a pediatric intensive care unit (PICU before and after implementation of an interface between computerized physician order entry (CPOE and pharmacy systems. Methods. Within a 72-bed PICU, medication and IVF orders in the CPOE system and bedside infusion pump settings were collected. Rates of discrepancy were calculated and categorized by type. Results were compared to a study conducted prior to interface implementation. Expansion of PICU also occurred between study periods. Results. Of 455 observations, discrepancy rate decreased for IVF (p=0.01 compared to previous study. Overall discrepancy rate for medications was unchanged; however, medications infusing without an order decreased (p<0.01, and orders without corresponding infusion increased (p<0.05. Conclusions. Following implementation of an interface between CPOE and pharmacy systems, fewer discrepancies between IVF orders and infusion pump settings were observed. Discrepancies for medications did not change, and some types of discrepancies increased. In addition to interface implementation, changes in healthcare delivery and workflow related to ICU expansion contributed to observed changes.

  1. Surgical aspects and complications of continuous intraperitoneal insulin infusion with an implantable pump

    NARCIS (Netherlands)

    Haveman, Jan Willem; Logtenberg, Susan J. J.; Kleefstra, Nanne; Groenier, Klaas H.; Bilo, Henk J. G.; Blomme, Adri M.

    2010-01-01

    Continuous intraperitoneal insulin infusion (CIPII) with an implantable pump is safe and effective in selected subjects with diabetes. Our aim was to assess surgical experience and complications with CIPII. We performed a retrospective longitudinal observational cohort study of patients that started

  2. Surgical aspects and complications of continuous intraperitoneal insulin infusion with an implantable pump

    NARCIS (Netherlands)

    Haveman, Jan Willem; Logtenberg, Susan J. J.; Kleefstra, Nanne; Groenier, Klaas H.; Bilo, Henk J. G.; Blomme, Adri M.

    Continuous intraperitoneal insulin infusion (CIPII) with an implantable pump is safe and effective in selected subjects with diabetes. Our aim was to assess surgical experience and complications with CIPII. We performed a retrospective longitudinal observational cohort study of patients that started

  3. Drug Delivery: Enabling Technology for Drug Discovery and Development. iPRECIO® Micro Infusion Pump: Programmable, Refillable, and Implantable

    OpenAIRE

    Tan, Tsung; Watts, Stephanie W.; Davis, Robert Patrick

    2011-01-01

    Successful drug delivery using implantable pumps may be found in over 12,500 published articles. Their versatility in delivering continuous infusion, intermittent or complex infusion protocols acutely or chronically has made them ubiquitous in drug discovery and basic research. The recent availability of iPRECIO®, a programmable, refillable, and implantable infusion pump has made it possible to carry out quantitative pharmacology (PKPD) in single animals. When combined with specialized cathet...

  4. Implementing smart pumps for epidural infusions in an academic medical center.

    Science.gov (United States)

    Kennerly, Julie; Jenkins, Alex; Lewis, Ashley N; Eckel, Stephen F

    2012-04-01

    A hospital's initial experience with the implementation of new smart-pump technology for epidural drug delivery is described, with a discussion of challenges and lessons learned during the implementation process. After a focused review of epidural medication use and prescribing patterns at the University of North Carolina Hospitals and Clinics (UNCH), a multidisciplinary team guided the selection of new smart pumps and the development of associated software tools. The new devices were programmed to display a "master drug library" of recommended drug concentrations, doses, and rates, which were consistent with newly created order sets intended to standardize prescriber ordering and nurse administration intended to help standardize prescriber ordering and nurse administration of adult and pediatric epidural infusions. However, data retrieved from the new units after several months of use indicated that nurses were still programming about 60% of epidural smart-pump infusions without using the onboard drug library (in effect circumventing the units' patient-safety software). In a survey of UNCH nursing staff, respondents indicated they were having difficulty in accessing the library and (when necessary) in manually programming the new devices. The hospital's experience highlighted a number of key points for institutions to consider during the implementation of new smart-pump technology. The implementation of new smart-pump technology for epidural infusions at UNCH revealed the importance of pump features and design in determining the devices' impact on patient safety. In particular, factors pertaining to ease of use (e.g., protocol-selection functions, programming procedures, data recording and retrieval capabilities) are crucial to the overall success of smart-pump implementation.

  5. The design and development of half extrusion type intelligent infusion pump%半挤压式智能输液泵的设计与研制

    Institute of Scientific and Technical Information of China (English)

    张彬; 李海云

    2015-01-01

    Aimed for the problems of traditional intravenous infusion in convenience, safety and reliability, half extrusion type intelligent infusion pump, a kind of piston infusion pump, was designed and developed in this paper. It stands out because of its portability, reliability, precise velocity control and transfusion status monitoring and alarm. The article first introduces the traditional intravenous fluids and the classification and principle of infusion pump, then the principle of infusion pump and the concrete structure design of half extrusion type piston is described in detail. Besides, the infusion velocity control methods are derived and the velocity precision of the half extrusion type intelligent infusion pump was successfully verified to be satisfying by the experiments.%针对传统静脉输液在便捷性、安全性与可靠性等方面的问题,本文设计并研制了半挤压式智能输液泵。它是一种活塞式输液泵,具有便携、操作简单可靠、流速控制精确等突出优点,并能对输液状态进行监测并报警。文章中首先介绍了传统静脉输液的不足以及输液泵的分类和原理,其次详细说明了半挤压式智能输液泵的工作原理及具体结构设计,然后对输液流速控制方法进行推导,最终通过实验成功证明半挤压式智能输液泵的输液流速精度满足设计要求。

  6. Pump control system for windmills

    Science.gov (United States)

    Avery, Don E.

    1983-01-01

    A windmill control system having lever means, for varying length of stroke of the pump piston, and a control means, responsive to the velocity of the wind to operate the lever means to vary the length of stroke and hence the effective displacement of the pump in accordance with available wind energy, with the control means having a sensing member separate from the windmill disposed in the wind and displaceable thereby in accordance with wind velocity.

  7. Drug delivery: enabling technology for drug discovery and development.iPRECIO® Micro Infusion Pump: Programmable, refillable and implantable

    Directory of Open Access Journals (Sweden)

    Tsung eTan

    2011-07-01

    Full Text Available Successful drug delivery using implantable pumps may be found in over 12,500 published articles. Their versatility in delivering continuous infusion, intermittent or complex infusion protocols acutely or chronically has made them ubiquitous in drug discovery and basic research. The recent availability of iPRECIO®, a programmable, refillable and implantable infusion pump has made it possible to carry out quantitative pharmacology (PKPD in single animals. When combined with specialized catheters, specific administration sites have been selected. When combined with radiotelemetry, the physiologic gold standard, more sensitive and powerful means of detecting drug induced therapeutic and/or adverse effects has been possible. Numerous application examples are cited from iPRECIO® use in Japan, United States and Europe with iPRECIO® as an enabling drug delivery device where the refillable and programmability functionality were key benefits. The ability to start/stop drug delivery and to have control periods prior dosing made it possible to have equivalent effects at a much lower dose than previously studied. Five different iPRECIO® applications are described in detail with references to the original work where the implantable, refillable and programmable benefits are demonstrated with their different end-points.

  8. Drug Delivery: Enabling Technology for Drug Discovery and Development. iPRECIO Micro Infusion Pump: Programmable, Refillable, and Implantable.

    Science.gov (United States)

    Tan, Tsung; Watts, Stephanie W; Davis, Robert Patrick

    2011-01-01

    Successful drug delivery using implantable pumps may be found in over 12,500 published articles. Their versatility in delivering continuous infusion, intermittent or complex infusion protocols acutely or chronically has made them ubiquitous in drug discovery and basic research. The recent availability of iPRECIO(®), a programmable, refillable, and implantable infusion pump has made it possible to carry out quantitative pharmacology (PKPD) in single animals. When combined with specialized catheters, specific administration sites have been selected. When combined with radiotelemetry, the physiologic gold standard, more sensitive and powerful means of detecting drug induced therapeutic, and/or adverse effects has been possible. Numerous application examples are cited from iPRECIO(®) use in Japan, United States, and Europe with iPRECIO(®) as an enabling drug delivery device where the refillable and programmability functionality were key benefits. The ability to start/stop drug delivery and to have control periods prior dosing made it possible to have equivalent effects at a much lower dose than previously studied. Five different iPRECIO(®) applications are described in detail with references to the original work where the implantable, refillable, and programmable benefits are demonstrated with their different end-points.

  9. Changes in fat concentration of human milk during delivery by intermittent bolus and continuous mechanical pump infusion.

    Science.gov (United States)

    Greer, F R; McCormick, A; Loker, J

    1984-11-01

    The changes in fat concentration and cumulative fat losses that occur during the delivery of human milk using two different continuous infusion systems were compared with the changes in fat concentration during simulated intermittent gavage or bolus feedings. With both mechanical pumps the largest cumulative fat losses and the greatest decreases in fat concentrations occurred at the slowest infusion rates. State of homogenization of the milk generally made little difference in the changes in fat concentration using the syringe pump, whereas homogenizing the milk increased the fat concentration significantly with the roller pump. With the syringe pump the positioning of the syringe tip (horizontal or vertical) made no difference in fat concentration at an infusion rate of 1 ml/hr, whereas at 4 and 7 ml/hr the fat concentration was increased significantly by keeping the syringe tip vertical. With either mechanical pump a large fat bolus was delivered during the eighth and final hour of infusion if the milk remaining in the tubing was recovered by using air infusion at the same infusion rate. Intermittent bolus delivery of human milk resulted in no significant loss of human milk fat, no changes in fat concentration, and no terminal delivery of a large fat load. Thus intermittent bolus feedings are preferred over continuous mechanical pump infusion systems for the delivery of human milk to low-birth-weight infants.

  10. Prolonged intracerebral convection-enhanced delivery of topotecan with a subcutaneously implantable infusion pump.

    Science.gov (United States)

    Sonabend, Adam M; Stuart, R Morgan; Yun, Jonathan; Yanagihara, Ted; Mohajed, Hamed; Dashnaw, Steven; Bruce, Samuel S; Brown, Truman; Romanov, Alex; Sebastian, Manu; Arias-Mendoza, Fernando; Bagiella, Emilia; Canoll, Peter; Bruce, Jeffrey N

    2011-08-01

    Intracerebral convection-enhanced delivery (CED) of chemotherapeutic agents currently requires an externalized catheter and infusion system, which limits its duration because of the need for hospitalization and the risk of infection. To evaluate the feasibility of prolonged topotecan administration by CED in a large animal brain with the use of a subcutaneous implantable pump. Medtronic Synchromed-II pumps were implanted subcutaneously for intracerebral CED in pigs. Gadodiamide (28.7 mg/mL), with or without topotecan (136 μM), was infused at 0.7 mL/24 h for 3 or 10 days. Pigs underwent magnetic resonance imaging before and at 6 times points after surgery. Enhancement and FLAIR+ volumes were calculated in a semi-automated fashion. Magnetic resonance spectroscopy-based topotecan signature was also investigated. Brain histology was analyzed by hematoxylin and eosin staining and with immunoperoxidase for a microglial antigen. CED of topotecan/gadolinium was well tolerated in all cases (n = 6). Maximum enhancement volume was reached at day 3 and remained stable if CED was continued for 10 days, but it decreased if CED was stopped at day 3. Magnetic resonance spectroscopy revealed a decrease in parenchymal metabolites in the presence of topotecan. Similarly, the combination of topotecan and gadolinium infusion led to a FLAIR+ volume that tended to be larger than that seen after the infusion of gadolinium alone. Histological analysis of the brains showed an area of macrophage infiltrate in the ipsilateral white matter upon infusion with topotecan/gadolinium. Intracerebral topotecan CED is well tolerated in a large animal brain for up to 10 days. Intracerebral long-term CED can be achieved with a subcutaneously implanted pump and provides a stable volume of distribution. This work constitutes a proof of principle for the safety and feasibility for prolonged CED, providing a means of continuous local drug delivery that is accessible to the practicing neuro-oncologist.

  11. Continuous subcutaneous infusion of glucagon by portable pump in non beta cell tumor hypoglycemia.

    Science.gov (United States)

    Houlbert, D; Altman, J J; Lageron, A; Capeau, J; Dahan, R; Friedberg, G; Wassef, M; Poffenbarger, P L; Segrestaa, J M

    1985-04-01

    Subcutaneous infusion of glucagon by portable pump appears to give very effective symptomatic relief from non beta cell tumor hypoglycemia when surgery, radiotherapy and chemotherapy are impossible or ineffective. This mode of glucagon administration was proposed in a patient who had severe nocturnal hypoglycemic attacks. The aim of the study was to specify the modes of utilization and to test the efficiency and the tolerance of this treatment. Glucagon was infused at 400 micrograms/h during every 12 hour night. Because of the hepatic action of glucagon it is very important to use this treatment with an adequate diet and to stop the infusion during the day to reconstitute the glycogen overload. This mode of glucagon administration was very effective in over 6 months of use and well tolerated.

  12. Automatic Control of Water Pumping Stations

    Institute of Scientific and Technical Information of China (English)

    Muhannad Alrheeh; JIANG Zhengfeng

    2006-01-01

    Automatic Control of pumps is an interesting proposal to operate water pumping stations among many kinds of water pumping stations according to their functions.In this paper, our pumping station is being used for water supply system. This paper is to introduce the idea of pump controller and the important factors that must be considering when we want to design automatic control system of water pumping stations. Then the automatic control circuit with the function of all components will be introduced.

  13. Specification and simulation of behavior of the Continuous Infusion Insulin Pump system.

    Science.gov (United States)

    Babamir, Seyed Morteza; Dehkordi, Mehdi Borhani

    2014-01-01

    Continuous Infusion Insulin Pump (CIIP) system is responsible for monitoring diabetic blood sugar. In this paper, we aim to specify and simulate the CIIP software behavior. To this end, we first: (1) presented a model consisting of the CIIP system behavior in response to its environment (diabetic) behavior and (2) we formally defined the safety requirements of the system environment (diabetic) in the Z formal modeling language. Such requirements should be satisfied by the CIIP software. Finally, we programmed the model and requirements.

  14. Organizational, Cultural, and Psychological Determinants of Smart Infusion Pump Work Arounds: A Study of 3 U.S. Health Systems.

    Science.gov (United States)

    Dunford, Benjamin B; Perrigino, Matthew; Tucker, Sharon J; Gaston, Cynthia L; Young, Jim; Vermace, Beverly J; Walroth, Todd A; Buening, Natalie R; Skillman, Katherine L; Berndt, Dawn

    2017-09-01

    We investigated nurse perceptions of smart infusion medication pumps to provide evidence-based insights on how to help reduce work around and improve compliance with patient safety policies. Specifically, we investigated the following 3 research questions: (1) What are nurses' current attitudes about smart infusion pumps? (2) What do nurses think are the causes of smart infusion pump work arounds? and (3) To whom do nurses turn for smart infusion pump training and troubleshooting? We surveyed a large number of nurses (N = 818) in 3 U.S.-based health care systems to address the research questions above. We assessed nurses' opinions about smart infusion pumps, organizational perceptions, and the reasons for work arounds using a voluntary and anonymous Web-based survey. Using qualitative research methods, we coded open-ended responses to questions about the reasons for work arounds to organize responses into useful categories. The nurses reported widespread satisfaction with smart infusion pumps. However, they reported numerous organizational, cultural, and psychological causes of smart pump work arounds. Of 1029 open-ended responses to the question "why do smart pump work arounds occur?" approximately 44% of the causes were technology related, 47% were organization related, and 9% were related to individual factors. Finally, an overwhelming majority of nurses reported seeking solutions to smart pump problems from coworkers and being trained primarily on the job. Hospitals may significantly improve adherence to smart pump safety features by addressing the nontechnical causes of work arounds and by providing more leadership and formalized training for resolving smart pump-related problems.

  15. Failure mode effect analysis applied to the use of infusion pumps.

    Science.gov (United States)

    Fechter, Richard J; Barba, Julio J

    2004-01-01

    Failure Mode Effect Analysis (FMEA) offers a prospective approach to reducing the risk associated with health care delivery. Beginning in February, 2002, an interdisciplinary team of fifteen individuals, including end-users, conducted an FMEA for the use of infusion pumps at UCSF Medical Center. The use of infusion pumps was identified as the area of highest risk, based on incident report data. The team identified sixteen potential failure modes, including their potential effects and causes, and assigned a risk priority number to each based on the potential severity, probability, and detectability of the failure. Notable failure modes included: incorrect programming; improper or inconsistent labeling of solution, tubing, and pump; potential use of malfunctioning or damaged pumps; and incorrect programming by nurses related to device design. The team then broke into smaller work groups and invited more end-users to perform root cause analyses and suggest recommended actions/outcome measures for each failure mode with a risk priority number of 32 or higher (on our scale of 1 to 64). Finally, the FMEA team assembled all of the data, prepared a final report, and assigned responsibility for key recommended actions.

  16. Method for controlling powertrain pumps

    Science.gov (United States)

    Sime, Karl Andrew; Spohn, Brian L; Demirovic, Besim; Martini, Ryan D; Miller, Jean Marie

    2013-10-22

    A method of controlling a pump supplying a fluid to a transmission includes sensing a requested power and an excess power for a powertrain. The requested power substantially meets the needs of the powertrain, while the excess power is not part of the requested power. The method includes sensing a triggering condition in response to the ability to convert the excess power into heat in the transmission, and determining that an operating temperature of the transmission is below a maximum. The method also includes determining a calibrated baseline and a dissipation command for the pump. The calibrated baseline command is configured to supply the fluid based upon the requested power, and the dissipation command is configured to supply additional fluid and consume the excess power with the pump. The method operates the pump at a combined command, which is equal to the calibrated baseline command plus the dissipation command.

  17. Tolerability, safety and efficacy of Iloprost infusion without peristaltic pump in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    S. Tosi

    2011-09-01

    Full Text Available Objective. To evaluate safety, tolerability and efficacy on Raynaud’s phenomenon (Rp of iloprost infusion without peristaltic pump in patients with systemic sclerosis (SSc. Patients and methods. The inclusion criteria were diagnosis of SSc, age between 18 and 65 years, presence of Rp, and absence of any controindication to the use of iloprost. The treatment was carried out in a day hospital setting and consisted first of 5 consecutive days of iloprost infusion (from an initial dose of 1.0 ng/Kg/min up to 2 ng/kg/min, and then of 2 days of infusions at the maximum possible dose every 45 days for one year. All of the adverse events were carefully recorded and the changes in the Rp were measured by a 5 grade scale (worsened, unmodified, slightly improved, very improved, disappeared. Results. Thirty-eight SSc patients (all females, mean age 49 years (range 18.5-65, disease duration 1.5 years (range 0.5-10.8 were enrolled in the study. During the first cycle of therapy, 14 avderse events occurred in 11 (28.9% patients and during the next cycles, 3 adverse events were seen in 3 (7.9% patients. In all of the cases they were mild and transient. Rp was considered very improved in 15 (39.5% patients, slightly improved in 13 (34.2%, unmodified in 8 (21% and worse in 2 (5.2%. Discussion. In this study intravenous iloprost without peristaltic pump proved to be safe, well tolerated, and as effective as traditional infusion through peristaltic pump in improving Rp in patients with SSc.

  18. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature 1

    Science.gov (United States)

    Wilson, Ana Maria Miranda Martins; Peterlini, Maria Angélica Sorgini; Pedreira, Mavilde da Luz Gonçalves

    2016-01-01

    ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. Results: all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. Conclusion: infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies. PMID:27533272

  19. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature

    Directory of Open Access Journals (Sweden)

    Ana Maria Miranda Martins Wilson

    Full Text Available ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. Results: all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. Conclusion: infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies.

  20. Needle and catheter colonization in pregnant diabetic patients using the continuous subcutaneous insulin infusion pump.

    Science.gov (United States)

    Rivera-Alsina, M E; Willis, S

    1984-01-01

    The incidence of bacterial colonization and risk of infection associated with the use of continuous insulin infusion pump (CIIP) was examined in 11 pregnant diabetic patients. All patients received instruction on specific aspects of CIIP and needle insertion technique according to the protocol used in our institution. A total of 220 cultures was performed on the subcutaneous needle and connective tubing. There was no clinical evidence of infection. In conclusion, the risk of infectious cutaneous complications in the pregnant diabetic patient using CIIP is not increased over the nonpregnant diabetic population.

  1. Catheter Migration After Implantationan Intrathecal Baclofen Infusion Pump for Severe Spasticity: A Case Report

    Directory of Open Access Journals (Sweden)

    Tung-Chou Li

    2008-09-01

    Full Text Available We report a case of intrathecal baclofen infusion pump implantation complicated by migration of the catheter tip. A 55-year-old man required an intrathecal baclofen infusion for severe spasticity 4 years after a cervical spinal cord injury with incomplete tetraparesis. Twelve months after initial implantation of the device, the patient began to experience a recurrence of trunk tightness and spasticity. Subsequent X-ray and computed tomography evaluations of the catheter system revealed pooling of contrast medium outside of the intrathecal distribution in the lumbar subcutaneous region of the back and therefore migration of the pump catheter tip. At surgical revision, emphasis was placed on minimizing the length of catheter outside of the spine and securing the catheter in the supraspinous fascia with a right-angled anchor. The distance between the anchors and the entry point of the catheter into the supraspinous fascia was also reduced to prevent slipping when the patient bends forward. After surgery, the patient's spasticity improved and, 1 year later, he has experienced no further complications during follow-up, requiring an average baclofen dose of 150 mg/day. Here, we describe several surgical methods intended to secure the intrathecal catheter and prevent catheter migration. Other complications related to catheter failure are also highlighted.

  2. Hepatic arterial infusion pump chemotherapy for colorectal liver metastases: an old technology in a new era.

    Science.gov (United States)

    Ko, Y J; Karanicolas, P J

    2014-02-01

    Aggressive treatment of colorectal cancer (crc) liver metastases can yield long-term survival and cure. Unfortunately, most patients present with technically unresectable metastases; conventional therapy in such patients consists of systemic therapy. Despite advances in the effectiveness of systemic therapy in the first-line setting, the tumour response rate and median survival remain low in the second-line setting. The preferential blood supply from the hepatic artery to crc liver metastases allows for excellent regional delivery of chemotherapy. Here, we review efficacy and safety data for hepatic artery infusion (hai) pump chemotherapy in patients with metastatic crc from the 5-fluorouracil era and from the era of modern chemotherapy. In selected patients with liver-only or liver-dominant disease who have progressed on first-line chemotherapy, hai combined with systemic agents is a viable therapeutic option when performed at experienced centres. Furthermore, significantly improved survival has been demonstrated with adjuvant hai therapy after liver resection in the phase iii setting. The complication rates and local toxicities associated with hai pump therapy are infrequent at experienced centres and can be managed with careful follow-up and early intervention. The major obstacles to the wide adoption of hai therapy include technical expertise for pump insertion and maintenance, and for floxuridine dose modification. The creation of formal preceptor-focused education and training in hai therapy for interdisciplinary medical professionals might encourage the creation and expansion of this liver-directed approach.

  3. A web-based study of the relationship of duration of insulin pump infusion set use and fasting blood glucose level in adults with type 1 diabetes.

    Science.gov (United States)

    Sampson Perrin, Alysa J; Guzzetta, Russell C; Miller, Kellee M; Foster, Nicole C; Lee, Anna; Lee, Joyce M; Block, Jennifer M; Beck, Roy W

    2015-05-01

    To evaluate the impact of infusion set use duration on glycemic control, we conducted an Internet-based study using the T1D Exchange's online patient community, Glu ( myGlu.org ). For 14 days, 243 electronically consented adults with type 1 diabetes (T1D) entered online that day's fasting blood glucose (FBG) level, the prior day's total daily insulin (TDI) dose, and whether the infusion set was changed. Mean duration of infusion set use was 3.0 days. Mean FBG level was higher with each successive day of infusion set use, increasing from 126 mg/dL on Day 1 to 133 mg/dL on Day 3 to 147 mg/dL on Day 5 (P<0.001). TDI dose did not vary with increased duration of infusion set use. Internet-based data collection was used to rapidly conduct the study at low cost. The results indicate that FBG levels increase with each additional day of insulin pump infusion set use.

  4. Improved usability of a multi-infusion setup using a central control display

    NARCIS (Netherlands)

    Doesburg, Frank; Cnossen, Fokeltje; Dieperink, Willem; Bult, Wouter; Nijsten, Maarten W

    2016-01-01

    Infusion pumps are often associated with poor usability and an increased likelihood of medication errors [1]. Critically ill patients in the intensive care unit (ICU) usually receive multiple infusions simultaneously, which increases the likelihood of pump-related errors. Furthermore, the ICU is fre

  5. An adjustable flow restrictor for implantable infusion pumps based on porous ceramics.

    Science.gov (United States)

    Jannsen, Holger; Klein, Stephan; Nestler, Bodo

    2015-08-01

    This paper describes an adjustable flow restrictor for use in gas-driven implantable infusion pumps, which is based on the resistance of a flow through a porous ceramic material. The flow inside the walls of a ceramic tube can be adjusted between 270 nl/min and 1260 nl/min by changing the flow path length in the ceramic over a distance of 14 mm. The long-term stability of the flow restrictor has been analyzed. A drift of -8% from the nominal value was observed, which lies within the required tolerance of ±10% after 30 days. The average time needed to change the flow rate is 40 s. In addition, the maximum adjustment time was 110 s, which also lies within the specification.

  6. Methods for studying medical device technology and practitioner cognition : The case of user-interface issues with infusion pumps

    NARCIS (Netherlands)

    Schraagen, J.M.C.; Verhoeven, F.

    2013-01-01

    Purpose : The aims of this study were to investigate how a variety of research methods is commonly employed to study technology and practitioner cognition. User-interface issues with infusion pumps were selected as a case because of its relevance to patient safety. Methods : Starting from a Cognitiv

  7. Methods for studying medical device technology and practitioner cognition: the case of user-interface issues with infusion pumps

    NARCIS (Netherlands)

    Schraagen, J.M.C.; Verhoeven, F.

    2013-01-01

    Purpose The aims of this study were to investigate how a variety of research methods is commonly employed to study technology and practitioner cognition. User-interface issues with infusion pumps were selected as a case because of its relevance to patient safety. Methods Starting from a Cognitive S

  8. Designing the modern pump: engineering aspects of continuous subcutaneous insulin infusion software.

    Science.gov (United States)

    Welsh, John B; Vargas, Steven; Williams, Gary; Moberg, Sheldon

    2010-06-01

    Insulin delivery systems attracted the efforts of biological, mechanical, electrical, and software engineers well before they were commercially viable. The introduction of the first commercial insulin pump in 1983 represents an enduring milestone in the history of diabetes management. Since then, pumps have become much more than motorized syringes and have assumed a central role in diabetes management by housing data on insulin delivery and glucose readings, assisting in bolus estimation, and interfacing smoothly with humans and compatible devices. Ensuring the integrity of the embedded software that controls these devices is critical to patient safety and regulatory compliance. As pumps and related devices evolve, software engineers will face challenges and opportunities in designing pumps that are safe, reliable, and feature-rich. The pumps and related systems must also satisfy end users, healthcare providers, and regulatory authorities. In particular, pumps that are combined with glucose sensors and appropriate algorithms will provide the basis for increasingly safe and precise automated insulin delivery-essential steps to developing a fully closed-loop system.

  9. Achieving effective glycaemic control using an insulin micro-pump.

    Science.gov (United States)

    Kelly, Peter

    2017-02-02

    For those with type 1 diabetes mellitus (T1DM), a deranged blood glucose level can cause hypo/hyperglycaemic episodes and in the long term contribute to microvascular disease. Such outcomes can effect concordance with insulin management regimens and affect the patient's quality of life. A variety of insulin delivery methods are available, including continuous subcutaneous insulin infusion (CSII) via either a tethered or patch pump. Pumps have the potential to improve delivery, monitoring and adjustment of insulin regimens, thus freeing patient's time and affording more control of their disease. This article reports how a new patch pump, has helped a cohort of patients to improve blood glucose variability levels and thus quality of life.

  10. [Research and application of microcontroller system for target controlled infusion].

    Science.gov (United States)

    Cheng, Yuke; Dou, Jianhong; Zhang, Xingan; Wang, Ruosong

    2005-08-01

    This paper presents a microcontroller system for target controlled infusion according to pharmacodynamic parameters of intravenous anesthetics. It can control the depth of anesthesia by adjusting the level of plasma concentrations. The system has the advantages of high precision, extending power and easy manipulation. It has been used in the clinical anesthesia.

  11. Radical resection for low rectal carcinoma combined with infusion pump chemotherapy via internal iliac artery

    Directory of Open Access Journals (Sweden)

    Bo YANG

    2011-10-01

    Full Text Available Objective To evaluate the effects and practicability of radical resection for low rectal carcinoma with infusion pump chemotherapy via internal iliac artery,and explore the correlation factors influencing the therapeutic effects.Methods Data of 316 patients with low rectal carcinoma,admitted from Oct.1997 to Mar.2008,were retrospectively analyzed and assigned into 2 groups according to the treatment: Patients received infusion pump chemotherapy via internal iliac artery to target area combined with intravenous systemic chemotherapy were assigned into group A(n=249,and those receiving systemic chemotherapy alone following radical resection were assigned to group B(n=67.The timing of pump chemotherapy to target area in group A was set at day 12 after recovery of digestive function,with regimen of 5-FU at 0.5g per dose plus hydroxycamptothecin at 10-15mg per dose,twice a week,four times as a treatment course for a total of 6 courses,and it was followed by intravenously systemic chemotherapy with a regimen of FOLFIRI or FOLFOX.In group B,at day 12 right after recovery of digestive function,the intravenous sytemic chemotherapy was started with the same regimen as in group A.The local recurrence rate,metastasis rate and survival rate after 1,3 and 5 years in the two groups were respectively observed and compared,and the correlation between the clinicopathological features and the 5 year local recurrence rates and survival rates was analyzed in patients of group A.Results In group A,the local recurrence rate at year 1,3 and 5 was 0,1.68%(4/238 and 3.79%(8/211,respectively,the metastasis rate was 0.80%(2/249,4.62%(11/238 and 10.90%(23/211,respectively,and the survival rate was 100%,77.73%(185/238 and 72.04%(152/211,respectively.In group B,the local recurrence rate at year 1,3 and 5 was 0,9.52%(6/63 and 16.36%(9/55,respectively,the metastasis rate was 1.49%(1/67,15.87%(10/63 and 27.27%(15/55,respectively,and the survival rate was 100

  12. Continuous Subcutaneous Insulin Infusion (CSII) Pumps for Type 1 and Type 2 Adult Diabetic Populations: An Evidence-Based Analysis.

    Science.gov (United States)

    2009-01-01

    therapy regimes can be administered by continuous insulin infusion (CSII) pumps. These devices attempt to closely mimic the behaviour of the pancreas, continuously providing a basal level insulin to the body with additional boluses at meal times. Modern CSII pumps are comprised of a small battery-driven pump that is designed to administer insulin subcutaneously through the abdominal wall via butterfly needle. The insulin dose is adjusted in response to measured capillary glucose values in a fashion similar to MDI and is thus often seen as a preferred method to multiple injection therapy. There are, however, still risks associated with the use of CSII pumps. Despite the increased use of CSII pumps, there is uncertainty around their effectiveness as compared to MDI for improving glycemic control. PART A: TYPE 1 DIABETIC ADULTS (#ENTITYSTARTX02265;19 YEARS) An evidence-based analysis on the efficacy of CSII pumps compared to MDI was carried out on both type 1 and type 2 adult diabetic populations. Are CSII pumps more effective than MDI for improving glycemic control in adults (≥19 years) with type 1 diabetes?Are CSII pumps more effective than MDI for improving additional outcomes related to diabetes such as quality of life (QoL)? Randomized controlled trials, systematic reviews, meta-analysis and/or health technology assessments from MEDLINE, EMBASE, CINAHLAdults (≥ 19 years)Type 1 diabetesStudy evaluates CSII vs. MDIPublished between January 1, 2002 - March 24, 2009Patient currently on intensive insulin therapy Studies with interest were glycosylated hemoglobin (HbA1c) levels, mean daily blood glucose, glucose variability, and frequency of hypoglycaemic events. Other outcomes of interest were insulin requirements, adverse events, and quality of life. The literature search strategy employed keywords and subject headings to capture the concepts of: 1) insulin pumps, and 2) type 1 diabetes. The search was run on July 6, 2008 in the following databases: Ovid MEDLINE (1996

  13. A comparison of three different target-controlled remifentanil infusion rates during target-controlled propofol infusion for oocyte retrieval

    Directory of Open Access Journals (Sweden)

    Demet Coskun

    2011-01-01

    Full Text Available OBJECTIVE: To evaluate the effects of three different target-controlled remifentanil infusion rates during target-controlled propofol infusion on hemodynamic parameters, pain, sedation, and recovery score during oocyte retrieval. METHODS: Sixty-nine women were scheduled for oocyte retrieval. Target-controlled propofol infusion at an effectsite concentration of 1.5 μg/mL was instituted. The patients were randomly allocated to receive remifentanil at an effect-site concentration of either 1.5 (group I, n = 23, 2 (group II, n = 23 or 2.5 ng/mL (group III, n = 23. Hemodynamic variables, sedation, pain, the Aldrete recovery score, and side effects were recorded. RESULTS: Hemodynamic variables, sedation and pain scores and the number of patients with the maximum Aldrete recovery score 10 min after the procedure were comparable among the groups. The number of patients in group III with the maximum Aldrete recovery score 5 min after the procedure was significantly lower than that in groups I and II. One patient in group II and one patient in group III suffered from nausea. CONCLUSION: Similar pain-free conscious sedation conditions without significant changes in hemodynamic parameters were provided by all three protocols. However, target controlled infusion of remifentanil at 1.5 or 2 ng/mL proved superior at providing early recovery compared to 2.5 ng/mL.

  14. A comparison of three different target-controlled remifentanil infusion rates during target-controlled propofol infusion for oocyte retrieval.

    Science.gov (United States)

    Coskun, Demet; Gunaydin, Berrin; Tas, Ayca; Inan, Gozde; Celebi, Hulya; Kaya, Kadir

    2011-01-01

    To evaluate the effects of three different target-controlled remifentanil infusion rates during target-controlled propofol infusion on hemodynamic parameters, pain, sedation, and recovery score during oocyte retrieval. Sixty-nine women were scheduled for oocyte retrieval. Target-controlled propofol infusion at an effect-site concentration of 1.5 μg/mL was instituted. The patients were randomly allocated to receive remifentanil at an effect-site concentration of either 1.5 (group I, n = 23), 2 (group II, n = 23) or 2.5 ng/mL (group III, n = 23). Hemodynamic variables, sedation, pain, the Aldrete recovery score, and side effects were recorded. Hemodynamic variables, sedation and pain scores and the number of patients with the maximum Aldrete recovery score 10 min after the procedure were comparable among the groups. The number of patients in group III with the maximum Aldrete recovery score 5 min after the procedure was significantly lower than that in groups I and II. One patient in group II and one patient in group III suffered from nausea. Similar pain-free conscious sedation conditions without significant changes in hemodynamic parameters were provided by all three protocols. However, target controlled infusion of remifentanil at 1.5 or 2 ng/mL proved superior at providing early recovery compared to 2.5 ng/mL.

  15. Success With Extended-Infusion Meropenem After Recurrence of Baclofen Pump-Related Achromobacter Xylosoxidans Meningitis in an Adolescent.

    Science.gov (United States)

    Nichols, Kristen R; Knoderer, Chad A; Jackson, Nicholas G; Manaloor, John J; Christenson, John C

    2015-08-01

    A 13-year-old female experienced a recurrence of baclofen pump-related central nervous system (CNS) infection caused by Achromobacter, despite absence of retained foreign material. Due to the failure of meropenem (120 mg/kg/d in divided doses every 8 hours and infused over 30 minutes) in the initial infection, the dose was infused over 4 hours during the recurrence. Meropenem is an antibiotic for which efficacy is time dependent, and 4-hour versus 30-minute infusions have been shown to prolong the time the concentration of the antibiotic exceeds the minimum inhibitory concentration (MIC) of the organism at the site of infection (T>MIC). Meropenem serum concentrations were obtained and indicated that T>MIC was at least 75% of the dosing interval. Our patient improved with no noted recurrences or adverse effects on the extended-infusion meropenem regimen. Utilization of extended-infusion beta-lactam dosing whenever possible in the treatment of serious infections caused by gram-negative organisms should be considered, as this dosing appears to be safe and improves the probability of achieving pharmacokinetic/pharmacodynamic goals.

  16. Testing and Discussion of Infusion Pump Based on Open Consumables%开放耗材输液泵的流速测试和讨论

    Institute of Scientific and Technical Information of China (English)

    张飚瑞

    2013-01-01

    Infusion pumps are commonly used in clinical,especially the open consumable infusion pumps,the consumable part of which adopting the gravity sets.However,dedicated infusing outfit is necessary for infusion pumps,so as to ensure the accuracy of the flow rate.Three kinds of infusion pipe were tested in 2 sets of infusion pump,and the results and relevant problems about flow rate of infusion pump are discussed in this paper.%输液泵在临床领域普遍使用,目前临床上使用的多是开放耗材输液泵,其耗材使用的都是重力输液器,而输液泵应该有专用的输液器,这样才能保证流速的精度.本文选取了3种不同的输液管路在2台输液泵上做测试,就测试结果和输液泵流速的相关问题进行讨论.

  17. Comparison of Insulin Pump Therapy (Continuous Subcutaneous Insulin Infusion) to Alternative Methods for Perioperative Glycemic Management in Patients with Planned Postoperative Admissions

    Science.gov (United States)

    Corney, Sarah M.; Dukatz, Tamra; Rosenblatt, Solomon; Harrison, Barbara; Murray, Robert; Sakharova, Alla; Balasubramaniam, Mamtha

    2012-01-01

    Background Patients with diabetes who use insulin pumps [continuous subcutaneous insulin infusion (CSII)] undergo surgeries that require postoperative hospital admission. There are no defined guidelines for CSII perioperative use. Methods This retrospective single-institution study identified type 1 and type 2 diabetes subjects by electronically searching 2005–2010 anesthesia preoperative assessments for “pump.” Surgical cases (n = 92) were grouped according to intraoperative insulin delivery method: (a) CSII continuation of basal rate with/without correctional insulin bolus(es) (n = 53); (b) conversion to intravenous insulin infusion (n = 20); and (c) CSII suspension with/without correctional insulin bolus(es) (n = 19). These groups were compared on mean intraoperative blood glucose (BG) and category of most extreme intraoperative BG. Results Differences were found on baseline characteristics of diabetes duration (p = .010), anesthesia time (p = .011), proportions receiving general anesthesia (p = .013), and preoperative BG (p = .033). The conversion group had the longest diabetes duration and anesthesia time; it had a higher proportion of general anesthesia recipients and a higher mean preoperative BG than the continuation group. There was no significant difference in mean BG/surgical case between continuation (163.5 ± 58.5 mg/dl), conversion (152.3 ± 28.9 mg/dl), and suspension groups (188.3 ± 44.9 mg/dl; p = .128). The suspension group experienced a greater percentage of cases (84.2%) with one or more intraoperative BG > 179 mg/dl than continuation (45.3%) and conversion (40%) groups Figure 1 groupings (p = .034). Conclusions In this limited sample, preliminary findings are consistent with similar intraoperative glycemic control between CSII continuation and CSII conversion to intravenous insulin infusions. Continuous subcutaneous insulin infusion suspension had a greater rate of hyperglycemia. Preoperative differences between insulin delivery groups

  18. Online feedback-controlled renal constant infusion clearances in rats.

    Science.gov (United States)

    Schock-Kusch, Daniel; Shulhevich, Yury; Xie, Qing; Hesser, Juergen; Stsepankou, Dzmitry; Neudecker, Sabine; Friedemann, Jochen; Koenig, Stefan; Heinrich, Ralf; Hoecklin, Friederike; Pill, Johannes; Gretz, Norbert

    2012-08-01

    Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique.

  19. Impact Analysis of Infusion Apparatus on Precision of Infusion Pump%浅谈医用输液器的质量对输液泵输液精度的影响

    Institute of Scientific and Technical Information of China (English)

    郭召平; 张祖进; 李辉

    2012-01-01

    Objective To analyze the impact of infusion apparatus on the precision of infusion pump. Methods The different infusion apparatuses were tested in the same circumstance by Datrend 2000E infusion analyzer. Results Imported infusion pump demanded more precise infusion apparatus, and the precision of homemade infusion pump was debasing in the application. Conclusion The application conditions of homemade infusion pump are realized by testing infusion apparatus. [Chinese Medical Equipment Journal,2012,33(7): 113-114]%目的:分析医用输液器的质量对输液泵输液精度的影响.方法:利用瑞典奥利科输液泵质量检测仪对输液器进行检测.结果:进口输液泵对输液器质量要求比较高,有些用国产输液器无法进行标定,要采用专门管道才能达到使用精度,对国产输液器兼容性比较差.国产输液泵虽然有些是全兼容国产输液器,但是使用过程中的精度将会降低.结论:通过对输液器的检测,了解国内输液泵的使用情况,要使用弹性好、质量好的输液器才能达到输液精度.

  20. Neurodegeneration in an Animal Model of Chronic Amyloid-beta Oligomer Infusion Is Counteracted by Antibody Treatment Infused with Osmotic Pumps.

    Science.gov (United States)

    Sajadi, Ahmadali; Provost, Chloé; Pham, Brendon; Brouillette, Jonathan

    2016-08-14

    Decline in hippocampal-dependent explicit memory (memory for facts and events) is one of the earliest clinical symptom of Alzheimer's disease (AD). It is well established that synapse loss and ensuing neurodegeneration are the best predictors for memory impairments in AD. Latest studies have emphasized the neurotoxic role of soluble amyloid-beta oligomers (Aβo) that begin to accumulate in the human brain approximately 10 to 15 yr before the clinical symptoms become apparent. Many reports indicate that soluble Aβo correlate with memory deficits in AD models and humans. The Aβo-induced neurodegeneration observed in neuronal and brain slice cultures has been more challenging to reproduce in many animal models. The model of repeated Aβo infusions shown here overcome this issue and allow addressing two key domains for developing new disease modifying therapies: identify biological markers to diagnose early AD, and determine the molecular mechanisms underpinning Aβo-induced memory deficits at the onset of AD. Since soluble Aβo aggregate relatively fast into insoluble Aβ fibrils that correlate poorly with the clinical state of patients, soluble Aβo are prepared freshly and injected once per day during six days to produce marked cell death in the hippocampus. We used cannula specially design for simultaneous infusions of Aβo and continuous infusion of Aβo antibody (6E10) in the hippocampus using osmotic pumps. This innovative in vivo method can now be used in preclinical studies to validate the efficiency of new AD therapies that might prevent the deposition and neurotoxicity of Aβo in pre-dementia patients.

  1. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature.

    Science.gov (United States)

    Wilson, Ana Maria Miranda Martins; Peterlini, Maria Angélica Sorgini; Pedreira, Mavilde da Luz Gonçalves

    2016-08-15

    to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies. identificar na literatura a produção científica acerca dos efeitos de bomba de infusão na administração de hemácias e avaliar as implicações do uso desses equipamentos na prática transfusional de enfermagem. revisão integrativa de literatura nas bases de dados Pubmed/Medline, Scopus, Biblioteca Virtual em Saúde, SciELO, Web of Science e Cochrane, utilizando os descritores "bombas de infusão", "transfusão de sangue", "transfusão de eritrócitos" e "hemólise". A data inicial não foi delimitada e a final foi dezembro de

  2. Using Variable Speed Control on Pump Application

    Directory of Open Access Journals (Sweden)

    Dr.Sc. Aida Spahiu

    2012-06-01

    Full Text Available Pumps are one of the most common variable speed drive (VSD system applications and special interest has focused on improving their energy efficiency by using variable speed control instead of throttling or other less efficient flow control methods. Pumps are the single largest user of electricity in industry in the European Union, consuming 160 TWh per annum of electricity and accounting for 79 million tonnes of carbon dioxide (CO2 emissions [1]. Centrifugal pumps are the most likely pump style to provide a favorable return based on energy savings when applied with a variable speed drive. To help illustrate this, are conducted benchmark testing to document various head and flow scenarios and their corresponding effect on energy savings. Paper shows the relationship of static and friction head in the energy efficiency equation and the effect of motor, pump and VSD efficiencies. The received results are good reference points for engineers and managers of water sector in Albania to select the best prospects for maximizing efficiency and energy savings.

  3. Aggregated Control of Domestic Heat Pumps

    DEFF Research Database (Denmark)

    Nielsen, Kirsten M.; Andersen, Palle; Pedersen, Tom S.

    2013-01-01

    A challenge in Denmark in the near future is to balance the electrical grid due to a large increase in the renewable energy production mainly from wind turbines. In this work an aggregated control system using heat pumps in single family houses to help balancing the grid is investigated. The cont...

  4. Lower dose basal insulin infusion has positive effect on glycaemic control for children with type I diabetes on continuous subcutaneous insulin infusion therapy.

    Science.gov (United States)

    Schulten, Ron J; Piet, Jessica; Bruijning, Patricia Cjl; de Waal, Wouter J

    2017-02-01

    The aim of our study was to explore a possible relationship between proportion of basal insulin dose (%BD/T) and glycaemic control in children with type I diabetes on continuous subcutaneous insulin infusion (CSII) therapy. All patients under the age of 18 with type I diabetes mellitus, treated in a general hospital in Utrecht, The Netherlands, who were on CSII therapy between 2000 and 2011 were selected for inclusion. All data as recorded during outpatient visits were retrospectively collected from patients' charts. Analyses were performed using R Statistical Software. Data of 847 outpatient visits of 78 patients [31 males (39.7%) and 47 females (60.3%)] were analyzed. Mean age at diagnosis was 7.1 ± 3.7 yr, mean age at start of pump therapy 10.1 ± 3.8 yr. Mean HbA1c before pump start was 8.3 ± 1.0%, median BMI standard deviation score for age and gender was 0.64 (-1.89-3.79). Median follow-up time per patient was 29 months with an average of 10 visits (range: 3-25). Multivariate analysis revealed that a change of 10% in %BD/T resulted in a decrease or increase of HbA1c of 0.22% [95% confidence interval (CI): 0.15-0.29). No significant effect was observed from SDS BMI, sex, or duration of diabetes. Low dose basal insulin infusion as a percentage of total insulin dose has a positive effect on metabolic outcome as expressed in HbA1c-levels. A change of 10% in %BD/T results in a decrease or increase of HbA1c of 0.22%. This supports the tendency to aim at the lowest basal insulin requirements in pump setting strategy. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Bomba de infusão de insulina em diabetes melito tipo 1 Insulin pump therapy in type 1 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Raphael Del Roio Liberatore Jr.

    2006-08-01

    Full Text Available OBJETIVO: Rever a experiência com a utilização da bomba de infusão de insulina em crianças e adolescentes, a fim de orientar o pediatra quanto às suas indicações e complicações. FONTE DOS DADOS : Foi realizada revisão sistemática de artigos publicados em literatura que abordassem a utilização da bomba de infusão de insulina, suas indicações, complicações e resposta ao tratamento. Dessa forma, todos os artigos publicados entre 1995 e 2005 foram resgatados através do levantamento em banco de dados MEDLINE e LILACS. As palavras-chave utilizadas foram: insulin pumps, type 1 diabetes mellitus e diabetes mellitus. Foram separados os artigos que, além disso, versassem sobre o assunto na faixa etária descrita SÍNTESE DOS DADOS: O uso da bomba de infusão de insulina em pacientes com diabetes melito tipo 1 não é uma necessidade para todos os pacientes, visto que, com tratamentos intensivos, os resultados conseguidos são muito parecidos, em termos de hemoglobina glicada e de controle de complicações a médio e longo prazo. No entanto, a bomba permite um maior conforto ao paciente, no sentido de que ele não precisa ficar tão restrito a horários rígidos de refeição e pode levar uma vida com melhor qualidade. Um primeiro requisito para quem pretenda usar a bomba é adaptar-se a aparelhos conectados ao corpo e a ter uma rotina de monitorização glicêmica rigorosa, pois, sem isso, as vantagens da bomba serão anuladas. As complicações, com os avanços tecnológicos de que dispomos atualmente, são muito infreqüentes. O custo, no entanto, é maior que nos tratamentos convencionais. CONCLUSÃO: Com a evolução das bombas de infusão e dos monitores de glicemia, incluindo sistemas de monitorização contínua, abre-se caminho para as "bombas inteligentes", e estaremos com um verdadeiro "pâncreas artificial", que pode mesmo ser implantado no paciente, permitindo uma vida com todas as regalias de uma pessoa não diab

  6. Kinetic vs. Thermodynamic Control of Bacteriorhodopsin Pumping

    Science.gov (United States)

    Gunner, Marilyn

    2011-03-01

    Bacteriorhodopsin is a transmembrane proton pump that converts light energy to a transmembrane electrochemical gradient. Retinal, bound in the center of the protein, absorbs light and isomerizes from the all-trans to 13-cis configuration. A series of conformational changes and proton transfers then restores the structure to the all-trans ground state while pumping one proton from the high pH cell interior to the low pH exterior, saving energy in an electrochemical gradient. Poorly understood gating elements control key steps where incorrect proton transfer would return the protein to the ground state without pumping. The gate's barrier height determines how much the pump leaks. Analysis of high-resolution structures trapped in different intermediates has produced ideas for how bacteriorhodopsin ensures pumping. There are two contrasting strategies, one primarily thermodynamic and the other relying on kinetic control to ensure that protons are moved uphill. With thermodynamic control, residue protonation states always remain in quasi-equilibrium. Relatively slow conformational changes shift the energy landscape modifying site pKas. Residues then change ionization remaining in equilibrium in each metastable intermediate. The sequence of intermediates imparts the directionality to the transfers. Alternatively, the direction of transfer is determined by the accessibility of low energy pathways so is thus is under kinetic control. We will discuss which steps in the bacteriorhodopsin photocycle are under thermodynamic or under kinetic control. The role of three specific conformational changes (retinal isomerization, Arg82 reorientation and Glu194 and 204 separations) on the degree of proton transfer will be described. Supported by NFS MCB 1022208. Carried out with Yifan Song now at the University of Washington Department of Biochemistry.

  7. [External lumbar drainage with volumetric continuing infusion pump in patients with cerebrospinal fluid leak. A case series].

    Science.gov (United States)

    Manso Melgosa, Ana Belén; García Gutiérrez, Helena; Fernández Porras, Mónica; Castrillo Manero, Ana Berta; Pérez Marijuán, Belén

    To describe the incidence and complications arising in a number of cases of patients with cerebrospinal fluid leak treated by external lumbar drainage with infusion pump (IP) volumetric continuous from 2001 to 2014. Quantify cerebrospinal fluid leak closed by lumbar drainage with IP. Retrospective descriptive case series study. patients undergoing transsphenoidal pituitary surgery, Chiari surgery and laminectomy, that developed postoperative cerebrospinal fluid leak treated with continuous external lumbar drainage by IP. age, sex, type of intervention, variables related to the practice of the pump and complications. Average and medians were calculated for quantitative variables, frequencies and percentages for qualitative. Sample: 11 subjects. Incidence in running IP: disconnection, occlusion and acoustic alarm activation. Most frequently complication is headache; a case of pneumocephalus. The small number of subjects and the heterogeneity of these do not allow for comparison or establishing associations between variables. The resolution of the cerebrospinal fluid leak with continuous IP is lower in this study than others, and may be influenced by the small number of subjects. It should be noted the frequent activation of the pump alarm for no apparent cause. Protocol would be developed for preparing the IP team to reduce the acoustic alarm activation, and would make a prospective multicenter study. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  8. Potential pitfalls of propofol target controlled infusion delivery related to its pharmacokinetics and pharmacodynamics.

    Science.gov (United States)

    Bienert, Agnieszka; Wiczling, Paweł; Grześkowiak, Edmund; Cywiński, Jacek B Jacek; Kusza, Krzysztof

    2012-01-01

    Target controlled infusion (TCI) devices are increasingly used in clinical practice. These devices unquestionably aid optimization of drug dosage. However, it still remains to be determined if they sufficiently address differences in pharmacological make up of individual patients. The algorithms guiding TCI pumps are based on pharmacological data obtained from a relatively small number of healthy volunteers, which are then extrapolated, on the basis of sophisticated pharmacokinetic and pharmacodynamic modeling, to predict plasma concentrations of the drug and its effect on general population. One has to realize the limitation of this approach: these models may be less accurate when applied to patients in extreme clinical conditions: in intensive care units, with a considerable loss of blood, severe hypothermia or temporary changes in the composition of plasma, e.g., hypoalbuminemia. In the future, data obtained under these "extreme" clinical circumstances, may be used to modify the dosage algorithms of propofol TCI systems to match the clinical scenario.

  9. Guidelines for Application of Continuous Subcutaneous Insulin Infusion (Insulin Pump) Therapy in the Perioperative Period

    Science.gov (United States)

    Boyle, Mary E; Seifert, Karen M; Beer, Karen A; Apsey, Heidi A; Nassar, Adrienne A; Littman, Stephanie D; Magallanez, Janice M; Schlinkert, Richard T; Stearns, Joshua D; Hovan, Michael J; Cook, Curtiss B

    2012-01-01

    Case reports indicate that diabetes patients receiving outpatient insulin pump therapy have been allowed to continue treatment during surgical procedures. Although allowed during surgery, there is actually little information in the medical literature on how to manage patients receiving insulin pump therapy during a planned surgical procedure. A multidisciplinary work group reviewed current information regarding the use of insulin pumps in the perioperative period. Although the work group identified safety issues specific to surgical scenarios, it believed that with the use of standardized guidelines and a checklist, continuation of insulin pump therapy during the perioperative period is feasible. A sample set of protocols have been developed and are summarized. A policy outlining clear procedures should be established at the institutional level to guide physicians and other staff if the devices are to be employed during the perioperative period. Additional clinical experience with the technology in surgical scenarios is needed, and consensus should be developed for insulin pump use in the perioperative phases of care. PMID:22401338

  10. Positron emission tomography and target-controlled infusion for precise modulation of brain drug concentration

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Olof [Uppsala Imanet AB, 751 85 Uppsala (Sweden); Department of Radiology, Oncology and Clinical Immunology, Division of Radiology, Uppsala University, 751 85 Uppsala (Sweden)], E-mail: olof.eriksson@uppsala.imanet.se; Josephsson, Ray [Clinical Imaging Unit, Novartis Pharma AG, CH 9057 Basel (Switzerland); Langstrom, Bengt [Uppsala Imanet AB, 751 85 Uppsala (Sweden); Bergstroem, Mats [Department of Pharmaceutical Biosciences, Faculty of Pharmacy, Uppsala University, 751 24 Uppsala (Sweden)

    2008-04-15

    Introduction: There are several instances when it is desirable to control brain concentration of pharmaceuticals, e.g., to modulate the concentration of anesthetic agents to different desired levels fitting to different needs during the course of surgery. This has so far only been possible using indirect estimates of drug concentration such as assuming constant relation between tissue and blood including extrapolations from animals. Methods: A system for controlling target tissue concentration (UIPump) was used to regulate whole-brain concentrations of a central benzodiazepine receptor antagonist at therapeutic levels with input from brain kinetics as determined with PET. The system was tested by using pharmacological doses of flumazenil mixed with tracer amounts of [{sup 11}C]flumazenil. Flumazenil was used as a model compound for anesthesia. An infusion scheme to produce three different steady-state levels in sequence was designed based on kinetic curves obtained after bolus injection. The subjects (Sprague-Dawley rats, n=6) were monitored in a microPET scanner during the whole experiment to verify resulting brain kinetic curves. Results: A steady-state brain concentration was rapidly achieved corresponding to a whole-brain concentration of 118{+-}6 ng/ml. As the infusion rate decreased to lower the exposure by a factor of 2, the brain concentration decreased to 56{+-}4 ng/ml. A third increased steady-state level of anesthesia corresponding to a whole-brain concentration of 107{+-}7 ng/ml was rapidly achieved. Conclusion: The experimental setup with computerized pump infusion and PET supervision enables accurate setting of target tissue drug concentration.

  11. New innovative glucose-controlled pump enabling glucose control in a pregnant patitient with diabetes

    DEFF Research Database (Denmark)

    Pilemann-Lyberg, Sascha; Solis, Anette Bratt; Mathiesen, Elisabeth R

    2014-01-01

    Abstract Continuous glucose monitoring enables innovative insulin pumps to stop infusion of insulin at selected blood glucose thresholds. We present the first and successful Danish clinical case using this device, a Medtronics Veo insulin pump, in a patient with numerous cases of severe...... hypoglycaemia during earlier pregnancies. During this treatment insulin infusion was frequently stopped and severe hypoglycaemia prevented in the remaining part of pregnancy...

  12. Combining situated Cognitive Engineering with a novel testing method in a case study comparing two infusion pump interfaces.

    Science.gov (United States)

    Schnittker, R; Schmettow, M; Verhoeven, F; Schraagen, J M C

    2016-07-01

    We validated the usability of a new infusion pump interface designed with a situated Cognitive Engineering approach by comparing it to a reference interface using a novel testing method employing repeated measurements and process measures, in addition to traditional outcome measures. The sample consisted of 25 nurses who performed eight critical tasks three times. Performance measures consisted of number and type of errors, deviations from a pre-established normative path solution, task completion times, number of keystrokes, mental effort and preferences in use. Results showed that interaction with the new interface resulted in 18% fewer errors, 90% fewer normative path deviations, 42% lower task completion times, 40% fewer keystrokes, 39% lower mental effort and 76% more subjective preferences in use. These outcomes suggest that within the scope of this case study, combining the situated Cognitive Engineering approach with a novel testing method addresses various shortcomings of earlier testing methods. Copyright © 2016 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  13. A fuzzy logic controller for hormone administration using an implantable pump

    Science.gov (United States)

    Coles, L. Stephen; Wells, George H., Jr.

    1994-01-01

    This paper describes the requirements for a Fuzzy Logic Controller for the physiologic administration of hormones by means of a FDA-approved surgically implantable infusion pump. Results of a LabVIEW computer simulation for the administration of insulin for diabetic adult patients as well as human growth hormone for pediatric patients are presented. A VHS video tape of the simulation in action has been prepared and is available for viewing.

  14. Comparative study between target-controlled-infusion and continuous-infusion anesthesia in dogs treated with methotrimeprazine and treated with propofol and remifentanil Estudo comparativo entre anestesia venosa total alvo-controlada e por infusão contínua em cães pré-tratados com levomepromazina e tratados com propofol e remifentanila

    Directory of Open Access Journals (Sweden)

    Eduardo Hatschbach

    2008-02-01

    Full Text Available PURPOSE: To compare two propofol infusion techniques in bitches subjected to ovaryhisterectomy by estimating the efficiency of the propofol target-dose, evaluating the cardiorespiratory and hemogasimetric attributes, and the bispectral scale index (BIS as well as the recovery period characteristics. METHODS: Twenty anesthetized bitches were divided into two groups of 10 each (G1, G2. Animals of G1 were pre-treated with methotrimeprazine and anesthetized with target-controlled propofol infusion by means of a Harvard infusion pump combined to remifentanil through a syringe pump. RESULTS: Bradycardia and light hypotension, hemogasimetric and respiratory stability besides a good myorelaxation, more evident during continuous infusion and good hypnosis. CONCLUSIONS: Dosis used in both techniques, after methotrimeprazine pre-treatment and combined to the opioid, were efficient for the surgery. The target-controlled anesthesia required a smaller anesthetic consumption (propofol with faster recovery periods.OBJETIVO: Comparar duas técnicas de infusão de propofol em cadelas submetidas à ovariohisterectomia, estudando a eficácia da dose alvo de propofol, avaliando os atributos cardiorrespiratórios, hemogasométricos e escala do índice bispectral, (BIS bem como as características do período de recuperação. MÉTODOS: Foram anestesiadas 20 cadelas, distribuídos em dois grupos (GI e GII. Em GI, os animais foram pré-tratados com levomepromazina e anestesiados com propofol por infusão alvo controlada, através de bomba de infusão Harvard pump, associado com remifentanila, através de bomba de seringa. Em GII, os animais receberam o mesmo tratamento de GI, só que ao invés de receberem o propofol por infusão alvo controlada, receberam o propofol em infusão contínua de velocidade fixa. RESULTADOS: Bradicardia e discreta hipotensão, estabilidade hemogasométrica e respiratória, além de um bom miorrelaxamento, mais evidente na infusão cont

  15. Insulin Analogs Applied with Continuous Subcutaneous Insulin Infusion (Pump in the Treatment of Diabetes

    Directory of Open Access Journals (Sweden)

    Ercan Tuncel

    2015-03-01

    Full Text Available Diabetes mellitus (DM is an important health problem that should be treated efficiently because of its high prevalence and high morbidity and mortality due to its complications. In patients with DM, the application of a treatment which provides physiologic insulin secretion as such in healthy individuals is directly related with the prevention of diabetes complications. Insulin analogs, which were developed in recent years and shown to have pharmacokinetic and pharmacodynamic superiority to human insulin, have made it possible to obtain natural insulin pattern in the body. In addition to development of insulin analogs, introduction of insulin application method of “continuous subcutaneous insulin infusion” (insulin pump has led a new era in the treatment of DM. In this review, treatment of type 1 and 2 DM patients with insulin analogs, particularly insulin aspart, applied with insulin pump was discussed in the light of the current literature.

  16. Energy Efficient Pump Control for an Offshore Oil Processing System

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Soleiman, Kian; Løhndorf, Bo

    2012-01-01

    The energy efficient control of a pump system for an offshore oil processing system is investigated. The seawater is lifted up by a pump system which consists of three identical centrifugal pumps in parallel, and the lifted seawater is used to cool down the crude oil flowing out of a threephase...... separator on one of the Danish north-sea platform. A hierarchical pump-speed control strategy is developed for the considered system by minimizing the pump power consumption subject to keeping a satisfactory system performance. The proposed control strategy consists of online estimation of some system...... operating parameters, optimization of pump configurations, and a real-time feedback control. Comparing with the current control strategy at the considered system, where the pump system is on/off controlled, and the seawater flows are controlled by a number of control valves, the proposed control strategy...

  17. Use of continuous subcutaneous insulin infusion by a portable insulin pump during pregnancy in women with type 1 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Zorić Svetlana

    2006-01-01

    Full Text Available Background/aim: Diabetes mellitus is associated with an increased risk for neonatal morbidity and mortality. One of the most important goals in treating pregnancies complicated with diabetes is keeping glucose level within the normal range, especially in the first trimester. A portable insulin pump for continuous subcutaneous insulin infusion (CSII represents the best form of therapy for patients with type 1 diabetes mellitus during pregnancy. The aim of our study was to evaluate the effects of therapy with a portable insulin pump for continuous subcutaneous insulin infusion during the first trimester of pregnancy on the quality of glycoregulation and pregnancy outcome in women with type 1 diabetes mellitus. Methods. A total of 17 newly diagnosed pregnant women with type 1 diabetes mellitus were treated with CSII therapy for three months. The parameters of glycoregulation (hemoglobin A, glycosylated - HbA1c, mean blood glucose value in daily profiles - MBG, daily requirement for insulin - IJ/kg BM, lipid levels, blood pressure and renal function were estimated before and after the therapy. These parameters were correlated with parameters of pregnancy outcome: fetal weight, APGAR score, duration of pregnancy. Results. There was a significant improvement in HbA1c (8.94±1.62 vs. 6.90±1.22 %, p < 0.05, MBG (9.23±2.22 vs. 6.41±1.72 mmol/l, p < 0.01, and daily requirement for insulin (0.66±0.22 vs. 0.55±0.13 IJ/kg BM, p < 0.05 during the CSII therapy. There were significant correlations between fetal weight and HbA1c (r = -0.60, p < 0.05, triglyceride levels (r = −0.63, p < 0.01, and the number of pregnancies (r = −0.62, p < 0.01, as well as between APGAR score and MBG (r = −0.52, p < 0.05 and cholesterol levels (r = −0.65, p < 0,01 before a portable insulin pump was applicated. Conclusions. There was a significant improvement in the quality of glycoregulation during CSII therapy in the pregnant women with type 1 diabetes mellitus. The

  18. A flatness-based control approach to drug infusion for cardiac function regulation

    Science.gov (United States)

    Rigatos, Gerasimos; Zervos, Nikolaos; Melkikh, Alexey

    2016-12-01

    A new control method based on differential flatness theory is developed in this article, aiming at solving the problem of regulation of haemodynamic parameters, Actually control of the cardiac output (volume of blood pumped out by heart per unit of time) and of the arterial blood pressure is achieved through the administered infusion of cardiovascular drugs, such as dopamine and sodium nitroprusside. Time delays between the control inputs and the system's outputs are taken into account. Using the principle of dynamic extension, which means that by considering certain control inputs and their derivatives as additional state variables, a state-space description for the heart's function is obtained. It is proven that the dynamic model of the heart is a differentially flat one. This enables its transformation into a linear canonical and decoupled form, for which the design of a stabilizing feedback controller becomes possible. The proposed feedback controller is of proven stability and assures fast and accurate tracking of the reference setpoints by the outputs of the heart's dynamic model. Moreover, by using a Kalman Filter-based disturbances' estimator, it becomes possible to estimate in real-time and compensate for the model uncertainty and external perturbation inputs that affect the heart's model.

  19. Flow manipulation and control methodologies for vacuum infusion processes

    Science.gov (United States)

    Alms, Justin B.

    Vacuum Infusion Processes (VIPs) are very attractive composite manufacturing processes since large structures such as fuselages and wind blades can be fabricated in a cost effective manner. In VIPs, the fabric layers are placed on a one sided mold which is closed by enveloping the entire mold with a thin plastic film and evacuating the air out. The vacuum compresses the fabric and when a resin inlet is opened, resin flows into the mold. The resin is allowed to cure before demolding the structure. However, VIPs causes non-repeatable and problematic resin filling patterns due to the heterogeneous nature of the material, nesting between various layers, and the hand labor utilized for laying up the fabric. The design of the manufacturing process routinely involves a trial and error model which make manufacturing costs and development time difficult to estimate. The clear solution to improving the reliability and robustness of VIPs is to implement a system capable of on-line flow control. While on-line flow control has been studied and developed for other composite manufacturing processes, the VIPs have been largely ignored as there are few process parameters that lend themselves to effective flow control. In this work, two new processes were discovered with the goal of on-line control of VIPs in mind. These two processes referred to as Flow Flooding Chamber (FFC) and Vacuum Induced Preform Relaxation (VIPR) will be discussed. They both employ an external vacuum chamber to influence the permeability of the fabric temporarily which allows one to redirect the resin flow to resin starved regions of the mold. The VIPR process in addition uses a low and regulated vacuum pressure in the external chamber to increase the permeability of the fabric in a controllable manner. The objective is to understand how the VIPR process affects the resin flow in order to implement it into a complete flow control and automated environment which will reduce or eliminate the variability

  20. Control Law Design for Propofol Infusion to Regulate Depth of Hypnosis: A Nonlinear Control Strategy

    Science.gov (United States)

    Khaqan, Ali; Bilal, Muhammad; Ilyas, Muhammad; Ijaz, Bilal; Ali Riaz, Raja

    2016-01-01

    Maintaining the depth of hypnosis (DOH) during surgery is one of the major objectives of anesthesia infusion system. Continuous administration of Propofol infusion during surgical procedures is essential but increases the undue load of an anesthetist in operating room working in a multitasking setup. Manual and target controlled infusion (TCI) systems are not good at handling instabilities like blood pressure changes and heart rate variability arising due to interpatient variability. Patient safety, large interindividual variability, and less postoperative effects are the main factors to motivate automation in anesthesia. The idea of automated system for Propofol infusion excites the control engineers to come up with a more sophisticated and safe system that handles optimum delivery of drug during surgery and avoids postoperative effects. In contrast to most of the investigations with linear control strategies, the originality of this research work lies in employing a nonlinear control technique, backstepping, to track the desired hypnosis level of patients during surgery. This effort is envisioned to unleash the true capabilities of this nonlinear control technique for anesthesia systems used today in biomedical field. The working of the designed controller is studied on the real dataset of five patients undergoing surgery. The controller tracks the desired hypnosis level within the acceptable range for surgery. PMID:27293475

  1. Control Law Design for Propofol Infusion to Regulate Depth of Hypnosis: A Nonlinear Control Strategy

    Directory of Open Access Journals (Sweden)

    Ali Khaqan

    2016-01-01

    Full Text Available Maintaining the depth of hypnosis (DOH during surgery is one of the major objectives of anesthesia infusion system. Continuous administration of Propofol infusion during surgical procedures is essential but increases the undue load of an anesthetist in operating room working in a multitasking setup. Manual and target controlled infusion (TCI systems are not good at handling instabilities like blood pressure changes and heart rate variability arising due to interpatient variability. Patient safety, large interindividual variability, and less postoperative effects are the main factors to motivate automation in anesthesia. The idea of automated system for Propofol infusion excites the control engineers to come up with a more sophisticated and safe system that handles optimum delivery of drug during surgery and avoids postoperative effects. In contrast to most of the investigations with linear control strategies, the originality of this research work lies in employing a nonlinear control technique, backstepping, to track the desired hypnosis level of patients during surgery. This effort is envisioned to unleash the true capabilities of this nonlinear control technique for anesthesia systems used today in biomedical field. The working of the designed controller is studied on the real dataset of five patients undergoing surgery. The controller tracks the desired hypnosis level within the acceptable range for surgery.

  2. Comparison and Discussion of Velocity Accuracy of the Multi-Functional Micro Syringe Pump and Micro Infusion Pump%多功能微量注药泵与微量输液泵的流速精度对比与探讨

    Institute of Scientific and Technical Information of China (English)

    柏正璐; 张华伟; 蒋红兵

    2016-01-01

    目的:检测多功能微量注药泵和微量输液泵的流速精度,分析多功能微量注药泵的优缺点。方法采用Fluke质控设备对多功能微量注药泵和微量输液泵的流速精度进行检测,对实测数据进行分析与讨论。结果这两种微量泵的流速精度检测均在误差范围之内,同时多功能微量注药泵具有流速精度高的特点,并且消除了输液过程中滴漏和回血的可能。结论多功能微量注药泵能够实现一机多用,适用于不同科室,且轻便易携,从而可提高医疗单位的设备利用率,降低医疗成本。%Objective To test the velocity accuracy of the multi-functional micro syringe pump and common micro infusion pump so as to analyze the advantages and disadvantages of the multi-function syringe pump. Methods Fluke professional quality control equipment was used to test the velocity accuracy of the multi-functional micro syringe pump and micro infusion pump. Then, analysis and discussion of the data measured were made. Results The velocity accuracy of both the multi-functional micro syringe pump and common micro infusion pump were within the error range. The multi-functional micro syringe pump was possessed of high velocity accuracy, which eliminated the possibilities of dripping and blood returning in the infusion process. Conclusion The multi-functional micro syringe pump made it possible to apply this all-in-one and portable machine in different departments, which improved the medical equipment utilization and reduced the health-care costs.

  3. Evaluation of a totally implanted venous access port and portable pump in a continuous chemotherapy infusion schedule on an outpatient basis.

    Science.gov (United States)

    Greidanus, J; de Vries, E G; Nieweg, M B; de Langen, Z J; Willemse, P H

    1987-11-01

    In this study we evaluated the feasibility of a totally implanted vascular access port (VAP) and portable infusion pump for cytostatic drug administration on an outpatient basis, in a 21-day continuous infusion schedule with 4-epidoxorubicin (phase I and phase II study) and mitoxantrone (phase I study). Patients were instructed to dissolve their own drugs at home. Fifty patients were treated with 114 cycles (2394 infusion days). The complication rate was low. In one patient thrombosis of the subclavian and superior caval vein resulted in the termination of treatment. One patient developed pulmonary embolism during treatment. Needle dislocation was observed in two patients. No septicaemia and no irreversible catheter occlusion were seen. Pump functioning was efficient and pump arrest (9 X) never lasted longer than 24 h. We conclude that a VAP and portable pump are a safe and reliable route of administration for cytostatic drugs on an outpatient basis and that patients are capable of preparing their own drugs at home without increase of complications.

  4. The Efficacy of Postoperative Wound Infusion with Bupivacaine for Pain Control after Cesarean Delivery: Randomized Double Blind Clinical Trial

    Directory of Open Access Journals (Sweden)

    Azin Alavi

    2007-06-01

    Full Text Available Objective: This study investigated the efficacy of bupivacaine wound infusion for pain control and opioid sparing effect after cesarean delivery.Materials and methods: We conducted a randomized double blind, placebo controlled clinical trial on 60 parturients undergoing cesarean section at a university hospital in Tehran. Patients were randomized to receive a pump infusion system that was filled with either 0.25% bupivacaine or equal volume of distilled water. A catheter was placed above the fascia and connected to electronic pump for 24 hours. Postoperative analog pain scores and morphine consumption were assessed at 6, 12 and 24 hours. Also time interval to first ambulation, length of hospitalization, complications and patient satisfaction were recorded. Data were analyzed using the SPSS software and P < 0.05 was considered statistically significant. Mann-Whitney u-test, student t-test and chi-square were used. Results: There were no differences in patient demographics and length of hospitalization and patient-generated resting pain scores between the two groups. Pain scores after coughing and leg raise during the first 6 postoperative hours were significantly less in the Bupivacaine group (P<0.001. The total dose of morphine consumption during the 24 hours study period was 2.5 ± 2.5 mg vs. 7.3 ± 2.7 mg for the bupivacaine and control groups, respectively (P<0.001. Compared with the control group, time to first ambulation was shorter in the bupivacaine group (11± 5h vs. 16 ± 4h (P< 0.01. Conclusion: Bupivacaine wound infusion was a simple and safe technique that provides effective analgesia and reduces morphine requirements after cesarean delivery.

  5. Simulation of a Hydraulic Pump Control Valve

    Science.gov (United States)

    Molen, G. Vander; Akers, A.

    1987-01-01

    This paper describes the mode of operation of a control valve assembly that is used with a hydraulic pump. The operating system of the valve is modelled in a simplified form, and an analogy for hydraulic resonance of the pressure sensing system is presented. For the control valve investigated, air entrainment, length and diameter of the resonator neck, and valve mass produced the greatest shift in resonant frequency. Experimental work was conducted on the hydraulic system so that the resonance levels and frequencies could be measured and the accuracy of the theory verified. The results obtained make it possible to evaluate what changes to any of the variables considered would be most effective in driving the second harmonic frequency above the operating range.

  6. Overall control and monitoring systems for pumped storage plants

    Energy Technology Data Exchange (ETDEWEB)

    Stepinski, B.; Cvetko, H.

    1982-01-01

    Experience and technical innovations in power plant engineering have resulted in continuous improvements of operation control, availability and safety of pumped storage plants. Process control is constantly improved as new developments are made in equipment and systems engineering. Plant control concepts with increasingly complex automation hierarchy are described by which pumped storage processes can be controlled optimally, reliably, and automatically.

  7. Skin regeneration in deep second-degree scald injuries either by infusion pumping or topical application of recombinant human erythropoietin gel

    Directory of Open Access Journals (Sweden)

    Giri P

    2015-05-01

    Full Text Available Priya Giri,1 Sabine Ebert,1 Ulf-Dietrich Braumann,2 Mathias Kremer,3 Shibashish Giri,1 Hans-Günther Machens,4 Augustinus Bader1 1Department of Cell Techniques and Applied Stem Cell Biology, Center for Biotechnology and Biomedicine (BBZ, Faculty of Medicine, University of Leipzig, Leipzig, Germany; 2Interdisciplinary Center for Bioinformatics (IZBI, University of Leipzig, Leipzig, Germany; 3Department of Plastic and Hand Surgery, University of Lübeck, Lübeck, Germany; 4Department of Plastic and Hand Surgery, Technical University of Munich, Munich, Germany Abstract: Large doses of recombinant growth factors formulated in solution form directly injected into the body is usual clinical practice in treating second-degree scald injuries, with promising results, but this approach creates side effects; furthermore, it may not allow appropriate levels of the factor to be sensed by the target injured tissue/organ in the specific time frame, owing to complications arising from regeneration. In this research, two delivery methods (infusion pumping and local topical application were applied to deliver recombinant human erythropoietin (rHuEPO for skin regeneration. First, rHuEPO was given in deep second-degree scald injury sites in mice by infusion pump. Vascularization was remarkably higher in the rHuEPO pumping group than in controls. Second, local topical application of rHuEPO gel was given in deep second-degree scald injury sites in rats. Histological analysis showed that epithelialization rate was significantly higher in the rHuEPO gel-treated group than in controls. Immunohistochemical studies showed that the rHuEPO gel-treated group showed remarkably higher expression of skin regeneration makers than the control group. An accurate method for visualization and quantification of blood vessel networks in target areas has still not been developed up to this point, because of technical difficulties in detecting such thin blood vessels. A method which

  8. Clinical evaluation of target controlled infusion system for sufentanil administration

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yan; ZHANG Li-ping; WU Xin-min; JIANG Jian-yu; DUAN Jing-li; HU Yong-fang; LI Min; LIU Wei; SHENG Xiao-yan; NI Cheng; XU Mao; GUO Xiang-yang

    2009-01-01

    Background Sufentanil target controlled infusion (TCI) provides stable analgesia, better hemodynamic control than a bolus injection of intravenous anesthetics, anticipated recovery and improved quality of anesthesia during perioperative period. This study evaluated the accuracy and feasibility of TCI system for sufentanil at high concentrations in Chinese surgical patients.Methods Twelve low risk adult patients undergoing elective surgery under general anesthesia were included in this study. Sufentanil was administered with a specific TCI system incorporating the population pharmacokinetic data of sufentanil previously reported, using a target effect-site concentration of sufentanil 4 or 6 ng/ml. Sufentanil TCI duration was 30 minutes. Frequent arterial blood samples were taken during and up to 24 hours after sufentanil TCI for determination of plasma sufentanil concentrations by liquid chromatography-mass spectrometry/mass spectrometry. The changes of circulatory system function during the precedure, recovery profile and adverse effects were recorded.Measured plasma sufentanil concentrations were compared with the values predicted by the TCI system. The bias (median performance error, MDPE), procision (median absolute performance error, MDAPE) and wobble (variability of performance error) of the sufentanil TCI system were determined.Results All patients had stable cardiovascular variables during induction and maintenance of anesthesia. Time to eye opening and extubation were (5.6±1.7) minutes when TCI set to 4 ng/ml and (7.2±9.3) minutes when set to 6 ng/ml.There was no episode of agitation, muscle rigidity or intraoperative awareness. The bias (MDPE), precision (MDAPE)and wobble of the sufentanil TCI system were -3.7%, 18.9% and 19.6% respectively during TCI, and the MDPE, MDAPE and wobble were -29.1%, 31.7% and 15.0% respectively after TCI (up to 8 hours).Conclusions The TCI system programmed for sufentanil at 4 or 6 ng/ml was considered acceptable for

  9. Savings potential of pump control systems; Sparpotenzial geregelter Pumpensysteme

    Energy Technology Data Exchange (ETDEWEB)

    Gontermann, D.

    2008-07-01

    This article takes a look at the potential for saving energy available if speed-control systems are used to regulate the speed and, as a result, the energy consumption of industrial pumps. The author quotes that around one third of power consumption in commercial buildings is used for powering pumps. Life-cycle costs of pumps, in which operation, maintenance and repair are also taken into account, are discussed. Methods of dimensioning pumps and the difficulties that can be encountered in doing this are discussed. The planning necessary to choose the correct pump power is discussed, as is the use of multi-stage pump installations and their control. Monitoring of the operation of pump installations is also examined.

  10. Prediction of Bispectral Index during Target-controlled Infusion of Propofol and Remifentanil: A Deep Learning Approach.

    Science.gov (United States)

    Lee, Hyung-Chul; Ryu, Ho-Geol; Chung, Eun-Jin; Jung, Chul-Woo

    2017-09-27

    The discrepancy between predicted effect-site concentration and measured bispectral index is problematic during intravenous anesthesia with target-controlled infusion of propofol and remifentanil. We hypothesized that bispectral index during total intravenous anesthesia would be more accurately predicted by a deep learning approach. Long short-term memory and the feed-forward neural network were sequenced to simulate the pharmacokinetic and pharmacodynamic parts of an empirical model, respectively, to predict intraoperative bispectral index during combined use of propofol and remifentanil. Inputs of long short-term memory were infusion histories of propofol and remifentanil, which were retrieved from target-controlled infusion pumps for 1,800 s at 10-s intervals. Inputs of the feed-forward network were the outputs of long short-term memory and demographic data such as age, sex, weight, and height. The final output of the feed-forward network was the bispectral index. The performance of bispectral index prediction was compared between the deep learning model and previously reported response surface model. The model hyperparameters comprised 8 memory cells in the long short-term memory layer and 16 nodes in the hidden layer of the feed-forward network. The model training and testing were performed with separate data sets of 131 and 100 cases. The concordance correlation coefficient (95% CI) were 0.561 (0.560 to 0.562) in the deep learning model, which was significantly larger than that in the response surface model (0.265 [0.263 to 0.266], P deep learning model-predicted bispectral index during target-controlled infusion of propofol and remifentanil more accurately compared to the traditional model. The deep learning approach in anesthetic pharmacology seems promising because of its excellent performance and extensibility.

  11. PLC-Based Pressure Control in Multi-Pump Applications

    Directory of Open Access Journals (Sweden)

    Vodovozov Valery

    2015-12-01

    Full Text Available The paper is devoted to the centrifugal pumps represented the most popular type of pumping equipment used in different areas. The pressure control approach for variable speed driven (VSD parallel connected centrifugal pumps is reported. The goal of the study is optimization of some quality indices, such as efficiency, consumed power, productivity, energy carrier temperature, heat irradiation, etc. One of them – efficiency – has been studied in the paper more carefully. The mathematical model of pumping process is discussed and a vector-matrix description of the multi-pump application is given. The program-based pressure control system is developed which productivity is changed by regulating the number of working pumps. The paper introduces new pressure control algorithms based on the working point estimation intended for programmable logical controllers (PLC. Experiments prove correctness of the offered methodology.

  12. Taming random lasers through active spatial control of the pump.

    Science.gov (United States)

    Bachelard, N; Andreasen, J; Gigan, S; Sebbah, P

    2012-07-20

    Active control of the spatial pump profile is proposed to exercise control over random laser emission. We demonstrate numerically the selection of any desired lasing mode from the emission spectrum. An iterative optimization method is employed, first in the regime of strong scattering where modes are spatially localized and can be easily selected using local pumping. Remarkably, this method works efficiently even in the weakly scattering regime, where strong spatial overlap of the modes precludes spatial selectivity. A complex optimized pump profile is found, which selects the desired lasing mode at the expense of others, thus demonstrating the potential of pump shaping for robust and controllable single mode operation of a random laser.

  13. Taming random lasers through active spatial control of the pump

    CERN Document Server

    Bachelard, Nicolas; Gigan, Sylvain; Sebbah, Patrick

    2012-01-01

    Active control of the pump spatial profile is proposed to exercise control over random laser emission. We demonstrate numerically the selection of any desired lasing mode from the emission spectrum. An iterative optimization method is employed, first in the regime of strong scattering where modes are spatially localized and can be easily selected using local pumping. Remarkably, this method works efficiently even in the weakly scattering regime, where strong spatial overlap of the modes precludes spatial selectivity. A complex optimized pump profile is found, which selects the desired lasing mode at the expense of others, thus demonstrating the potential of pump shaping for robust and controllable singlemode operation of a random laser.

  14. Optimization of insulin pump therapy based on high order run-to-run control scheme.

    Science.gov (United States)

    Tuo, Jianyong; Sun, Huiling; Shen, Dong; Wang, Hui; Wang, Youqing

    2015-07-01

    Continuous subcutaneous insulin infusion (CSII) pump is widely considered a convenience and promising way for type 1 diabetes mellitus (T1DM) subjects, who need exogenous insulin infusion. In the standard insulin pump therapy, there are two modes for insulin infusion: basal and bolus insulin. The basal-bolus therapy should be individualized and optimized in order to keep one subject's blood glucose (BG) level within the normal range; however, the optimization procedure is troublesome and it perturb the patients a lot. Therefore, an automatic adjustment method is needed to reduce the burden of the patients, and run-to-run (R2R) control algorithm can be used to handle this significant task. In this study, two kinds of high order R2R control methods are presented to adjust the basal and bolus insulin simultaneously. For clarity, a second order R2R control algorithm is first derived and studied. Furthermore, considering the differences between weekdays and weekends, a seventh order R2R control algorithm is also proposed and tested. In order to simulate real situation, the proposed method has been tested with uncertainties on measurement noise, drifts, meal size, meal time and snack. The proposed method can converge even when there are ±60 min random variations in meal timing or ±50% random variations in meal size. According to the robustness analysis, one can see that the proposed high order R2R has excellent robustness and could be a promising candidate to optimize insulin pump therapy. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. The relative effectiveness of pumps over MDI and structured education (REPOSE) : study protocol for a cluster randomised controlled trial

    OpenAIRE

    White, David; Waugh, Norman; Elliott, Jackie; Lawton, Julia; Barnard, Katharine D.; Campbell, Michael J; Dixon, S.; Heller, Simon

    2014-01-01

    Introduction: People with type 1 diabetes (T1DM)\\ud require insulin therapy to sustain life, and need optimal\\ud glycaemic control to prevent diabetic ketoacidosis and\\ud serious long-term complications. Insulin is generally\\ud administered using multiple daily injections but can also\\ud be delivered using an infusion pump (continuous\\ud subcutaneous insulin infusion), a more costly option\\ud with benefits for some patients. The UK National\\ud Institute for Health and Care Excellence (NICE)\\u...

  16. Target-controlled infusion (Propofol versus inhaled anaesthetic (Sevoflurane in patients undergoing shoulder arthroscopic surgery

    Directory of Open Access Journals (Sweden)

    Thrivikrama Padur Tantry

    2013-01-01

    Full Text Available Background: One of the challenges of anaesthesia for shoulder arthroscopic procedures is the need for controlled hypotension to lessen intra-articular haemorrhage and thereby provide adequate visualisation to the surgeon. Achievement of optimal conditions necessitates several interventions and manipulations by the anaesthesiologist and the surgeon, most of which directly or indirectly involve maintaining intra-operative blood pressure (BP control. Aim: This study aimed to compare the efficacy and convenience of target controlled infusion (TCI of propofol and inhalational agent sevoflurane in patients undergoing shoulder arthroscopic surgery after preliminary inter-scalene blockade. Methods: Of thirty four patients studied, seventeen received TCI propofol (target plasma concentration of 3 μg/ml and an equal number, sevoflurane (1.2-1.5 Minimum Alveolar Concentration. N 2 O was used in both groups. Systolic, diastolic, mean blood pressures and heart rate were recorded regularly throughout the procedure. All interventions to control BP by the anaesthesiologist and pump manipulation requested by the surgeon were recorded. The volume of saline irrigant used and the haemoglobin (Hb content of the return fluid were measured. Results: TCI propofol could achieve lower systolic, mean BP levels and the number of interventions required was also lower as compared to the sevoflurane group. The number of patients with measurable Hb was lower in the TCI propofol group and this translated into better visualisation of the joint space. A higher volume of saline irrigant was required in the sevoflurane group. No immediate peri-operative anaesthetic complications were noted in either category. Conclusion: TCI propofol appears to be superior to and more convenient than sevoflurane anaesthesia in inter-scalene blocked patients undergoing shoulder arthroscopy.

  17. Overall control and monitoring systems for pumped storage plants

    Energy Technology Data Exchange (ETDEWEB)

    Stepinski, B.; Cvetko, H.

    1982-06-01

    The article describes control and monitoring concepts in which the delegation of responsibility is becoming more decisive than ever (automation hierarchy), and which are capable of optimized, automatic control of process events in pumped storage plants. 8 refs.

  18. The Effect of an Amino Acid Infusion on Central Thermoregulatory Control in Humans

    Science.gov (United States)

    Nakajima, Yasufumi; Takamata, Akira; Matsukawa, Takashi; Sessler, Daniel I.; Kitamura, Yoshihiro; Ueno, Hiroshi; Tanaka, Yoshifumi; Mizobe, Toshiki

    2005-01-01

    Background Administration of protein or amino acids enhances thermogenesis, presumably by stimulating oxidative metabolism. However, hyperthermia results even when thermoregulatory responses are intact, suggesting that amino acids also alter central thermoregulatory control. We thus tested the hypothesis that amino acid infusion increases the thermoregulatory setpoint. Methods Nine male volunteers each participated on four study days in randomized order: 1) intravenous amino acids infused at 4 kJ·kg−1·hr−1 for 2.5 h combined with skin-surface warming; 2) amino acid infusion combined with cutaneous cooling; 3) a saline infusion combined with skin-surface warming; and, 4) saline infusion combined with cutaneous cooling. Results Amino acid infusion increased resting core temperature by 0.3 ± 0.1°C (mean ± SD) and oxygen consumption by 18 ± 12%. Furthermore, amino acid infusion increased the calculated core temperature threshold (triggering core temperature at a designated mean-skin temperature of 34°C) for active cutaneous vasodilation by 0.3 ± 0.3°C, for sweating by 0.2 ± 0.2°C, for thermoregulatory vasoconstriction by 0.3 ± 0.3°C, and for thermogenesis by 0.4 ± 0.5°C. Amino acid infusion did not alter the incremental response intensity (i.e., gain) of thermoregulatory defenses. Conclusions Amino acid infusion increased the metabolic rate and resting core temperature. However, amino acids also produced a synchronous increase in all major autonomic thermoregulatory defense thresholds; the increase in core temperature was identical to the setpoint increase — even in a cold environment with amble potential to dissipate heat. In subjects with intact thermoregulatory defenses, amino acid-induced hyperthermia appears to result from an elevated setpoint increase rather than increased metabolic rate per se. PMID:15108979

  19. Intravenous sodium valproate versus diazepam infusion for the control of refractory status epilepticus in children: a randomized controlled trial.

    Science.gov (United States)

    Mehta, Vishal; Singhi, Pratibha; Singhi, Sunit

    2007-10-01

    An open-label, randomized controlled study was conducted at a tertiary care teaching hospital to compare efficacy and safety of intravenous sodium valproate versus diazepam infusion for control of refractory status epilepticus. Forty children with refractory status epilepticus were randomized to receive either intravenous sodium valproate or diazepam infusion. Refractory status epilepticus was controlled in 80% of the valproate and 85% of the diazepam patients. The median time to control refractory status epilepticus was less in the valproate group (5 minutes) than the diazepam group (17 minutes; P diazepam group 60% required ventilation and 50% developed hypotension after starting diazepam infusion. No adverse effects on liver functions were seen with valproate. It is concluded that intravenous sodium valproate is an effective alternative to diazepam infusion in controlling refractory status epilepticus in children and is free of respiratory depression and hypotension.

  20. COMPARISON OF PATIENT CONTROLLED EPIDURAL ANALGESIA WITH CONTINUOUS EPIDURAL INFUSION FOR LABOUR ANALGESIA

    Directory of Open Access Journals (Sweden)

    Sumaiah Tahseen

    2016-07-01

    Full Text Available We conducted a study to compare the efficacy and safety of Patient Controlled Epidural Analgesia (PCEA with that of Continuous Infusion of Epidural Analgesia (CIEA for maintenance of labour analgesia and evaluated the quality of analgesia and obstetric and safety outcomes. METHODS The study was a hospital-based prospective, randomised control trial on 80 parturients who had a normal antenatal period. Each parturient received 500-1000 mL lactated ringer solution Intravenously (IV prior to initiating epidural blockade. Epidural catheter placement was performed in a standard manner and all patients received an initial dose of 8-10 mL bupivacaine 0.25%. Parturients self-administered 0.125% bupivacaine with fentanyl 2.5 µg/mL using PCA pumps programmed as follows: 4 mL bolus with a 20 mins Lockout Interval (LI. Group B received CIEA of 8 mL 0.125% bupivacaine with fentanyl 2.5/mL. Hourly assessments included: VAS scores for pain and satisfaction, sensory and motor block, analgesic supplements, bupivacaine and fentanyl consumption. RESULTS Data from 80 patients showed no differences among groups in pain relief. Maternal satisfaction was greater in PCEA group. Anaesthetic interventions by way of supplemental doses of Bupivacaine and Fentanyl in the PCEA group were minimal (4 and 2 vs 25 and 12 P <0.001 compared to CEI group. PCEA group received less local anaesthetic (5.2 vs 9.4 p <0.001 and few patients in PCEA group had motor weakness compared to CEI group (6 vs 17 p <0.05. Both methods were safe for mother and newborn. CONCLUSION Patients who received PCEA required less anaesthetic interventions, required lower doses of local anaesthetic, fentanyl and have less motor weakness than those who received CEI.

  1. Does prolonged β-lactam infusions improve clinical outcomes compared to intermittent infusions? A meta-analysis and systematic review of randomized, controlled trials

    Directory of Open Access Journals (Sweden)

    Van Arendonk Kyle J

    2011-06-01

    Full Text Available Abstract Background The emergence of multi-drug resistant Gram-negatives (MDRGNs coupled with an alarming scarcity of new antibiotics has forced the optimization of the therapeutic potential of available antibiotics. To exploit the time above the minimum inhibitory concentration mechanism of β-lactams, prolonging their infusion may improve outcomes. The primary objective of this meta-analysis was to determine if prolonged β-lactam infusion resulted in decreased mortality and improved clinical cure compared to intermittent β-lactam infusion. Methods Relevant studies were identified from searches of MEDLINE, EMBASE, and CENTRAL. Heterogeneity was assessed qualitatively, in addition to I2 and Chi-square statistics. Pooled relative risks (RR and 95% confidence intervals (CI were calculated using Mantel-Haenszel random-effects models. Results Fourteen randomized controlled trials (RCTs were included. Prolonged infusion β-lactams were not associated with decreased mortality (n= 982; RR 0.92; 95% CI:0.61-1.37 or clinical cure (n = 1380; RR 1.00 95% CI:0.94-1.06 compared to intermittent infusions. Subgroup analysis for β-lactam subclasses and equivalent total daily β-lactam doses yielded similar results. Most studies had notable methodological flaws. Conclusions No clinical advantage was observed for prolonged infusion β-lactams. The limited number of studies with MDRGNs precluded evaluation of prolonged infusion of β-lactams for this subgroup. A large, multicenter RCT with critically ill patients infected with MDRGNs is needed.

  2. Servo Controlled Variable Pressure Modification to Space Shuttle Hydraulic Pump

    Science.gov (United States)

    Kouns, H. H.

    1983-01-01

    Engineering drawings show modifications made to the constant pressure control of the model AP27V-7 hydraulic pump to an electrically controlled variable pressure setting compensator. A hanger position indicator was included for continuously monitoring hanger angle. A simplex servo driver was furnished for controlling the pressure setting servovalve. Calibration of the rotary variable displacement transducer is described as well as pump performance and response characteristics.

  3. Application of implantable infusion pump in the treatment of lvier carcinoma%埋植式药泵在肝癌治疗中的应用

    Institute of Scientific and Technical Information of China (English)

    王家胜; 凡水田; 黄建宏; 李保家

    2001-01-01

    目的 探讨对不能切除的肝癌患者术中应用埋植式药泵治疗的临床意义。方法 对28例肝癌患者, 术中作肝动脉和门静脉插管并皮下埋植药泵, 术中、术后经药泵进行肝脏局部灌注化疗取得了较好的疗效。结果 本组治疗后有效率为64.2%, 其中生存时间小于6个月15例, 6~12个月10例, 12个月以上3例其中1例存活22个月以上。结论 肝动脉局部灌注化疗对不能手术切除的晚期肝癌, 作为治疗手段不失为一种有效的方法。%Objective To investigate the efficacy of implantable infusion pump in the treatment of un-resectable liver cancer. Methods Twenty-eight patients with liver cancer were subjected to the subcutaneous implantation of chemotherapy infusion pump into hepatic artery and portal vein during operation, and hepatic local perfusion chemotherapy via the pump was performed during and after operation. Results In this group, the total effective rate was 64.2%. The survival time was less than 6 months in 15 cases, 6 to 12 months in 10 cases and over 12 months in 3 cases. Conclusions The local infusion chemotherapy via hepatic artery and portal vein was an effective therapy for those who could not undergo the resection of advanced liver cancer.

  4. Effect of nitrous oxide on cisatracurium infusion demands: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Illman Hanna L

    2010-08-01

    Full Text Available Abstract Background Recent studies have questioned our previous understanding on the effect of nitrous oxide on muscle relaxants, since nitrous oxide has been shown to potentiate the action of bolus doses of mivacurium, rocuronium and vecuronium. This study was aimed to investigate the possible effect of nitrous oxide on the infusion requirements of cisatracurium. Methods 70 ASA physical status I-III patients aged 18-75 years were enrolled in this randomized trial. The patients were undergoing elective surgery requiring general anesthesia with a duration of at least 90 minutes. Patients were randomized to receive propofol and remifentanil by target controlled infusion in combination with either a mixture of oxygen and nitrous oxide (Nitrous oxide/TIVA group or oxygen in air (Air/TIVA group. A 0.1 mg/kg initial bolus of cisatracurium was administered before tracheal intubation, followed by a closed-loop computer controlled infusion of cisatracurium to produce and maintain a 90% neuromuscular block. Cumulative dose requirements of cisatracurium during the 90-min study period after bolus administration were measured and the asymptotic steady state rate of infusion to produce a constant 90% block was determined by applying nonlinear curve fitting to the data on the cumulative dose requirement during the study period. Results Controller performance, i.e. the ability of the controller to maintain neuromuscular block constant at the setpoint and patient characteristics were similar in both groups. The administration of nitrous oxide did not affect cisatracurium infusion requirements. The mean steady-state rates of infusion were 0.072 +/- 0.018 and 0.066 +/- 0.017 mg * kg-1 * h-1 in Air/TIVA and Nitrous oxide/TIVA groups, respectively. Conclusions Nitrous oxide does not affect the infusion requirements of cisatracurium. Trial registration ClinicalTrials.gov NCT01152905; European Clinical Trials Database at http://eudract.emea.eu.int/2006-006037-41.

  5. Assessment of the Value of the Clinical Application of Special Infusion Pump Pipe%专用输液泵管路临床应用价值的评估

    Institute of Scientific and Technical Information of China (English)

    邵蕾; 杨坤; 乐莹; 郑博

    2012-01-01

    The clinical application value of infusion pumps dedicated infusion device was evaluated through the comparison on the accuracy between dedicated and non-specific infusion devices. Experiments were conducted by using five test points each repeated three times to detecting accuracy of the infusion of the three kinds of infusion devices. Through the analysis of test results, we found out that the infusion accuracy of special and non-dedicated infusion devices in the experiment, exists significant differences (P <0.05), and we believe that the use of infusion pumps dedicated infusion devicecan guarantees safety and reduces medical risks in clinical.%通过比较专用与非专用输液器对输液泵输液精度的影响,评估输液泵专用输液器的临床应用价值.实验采用五个测试点每点重复三次的方法对三种输液器的输液精度进行检测.通过对测试结果的分析,发现专用输液器与非专用输液器在实验中的输液精度存在显著的差异(P<0.05),认为使用输液泵专用输液器,能为临床输液治疗提供安全保障,降低医疗风险.

  6. Continuous Drug Infusion for Diabetes Therapy: A Closed-Loop Control System Design

    Directory of Open Access Journals (Sweden)

    Jiming Chen

    2008-03-01

    Full Text Available While a typical way for diabetes therapy is discrete insulin infusion based on long-time interval measurement, in this paper, we design a closed-loop control system for continuous drug infusion to improve the traditional discrete methods and make diabetes therapy automatic in practice. By exploring the accumulative function of drug to insulin, a continuous injection model is proposed. Based on this model, proportional-integral-derivative (PID and fuzzy logic controllers are designed to tackle a control problem of the resulting highly nonlinear plant. Even with serious disturbance of glucose, such as nutrition absorption at meal time, the proposed scheme can perform well in simulation experiments.

  7. Continuous Drug Infusion for Diabetes Therapy: A Closed-Loop Control System Design

    Directory of Open Access Journals (Sweden)

    Xiao Yang

    2008-01-01

    Full Text Available Abstract While a typical way for diabetes therapy is discrete insulin infusion based on long-time interval measurement, in this paper, we design a closed-loop control system for continuous drug infusion to improve the traditional discrete methods and make diabetes therapy automatic in practice. By exploring the accumulative function of drug to insulin, a continuous injection model is proposed. Based on this model, proportional-integral-derivative (PID and fuzzy logic controllers are designed to tackle a control problem of the resulting highly nonlinear plant. Even with serious disturbance of glucose, such as nutrition absorption at meal time, the proposed scheme can perform well in simulation experiments.

  8. How to control propofol infusion in pediatric patients undergoing gamma knife radiosurgery.

    Science.gov (United States)

    Kamata, Kotoe; Hayashi, Motohiro; Muragaki, Yoshihiro; Iseki, Hiroshi; Okada, Yoshikazu; Ozaki, Makoto

    2013-01-01

    Although Gamma Knife radiosurgery (GKS) is commonly performed under local anesthesia, general anesthesia is sometimes required. The authors previously reported a remote-controlled patient management system consisting of propofol-based general anesthesia with a target-controlled infusion (TCI) that we designed for pediatric GKS. However, a commercially available propofol TCI system has age and weight limitations (propofol appropriate for pediatric GKS. A pharmacokinetic model of the TIVA Trainer© with Paedfusor's parameter was used. A manually controlled infusion scheme to achieve a sufficient level of propofol for pediatric GKS was examined in five models ranging from 10 to 30 kg. Following a loading dose of 3.0 mg/kg, the combination of continuous infusion of 14, 12, 10, and 8 mg/kg/h resulted in a target concentration of 3.0-4.0 μg/ml, the required level for pediatric GKS. Propofol titration is a key issue in GKS. Manual infusion is less accurate than TCI, but the combination of a small bolus and continuous infusion might be a substitute. Considering the characteristics of propofol pharmacokinetics in children, co-administration of opioids is recommended.

  9. [The research on a pocket microcontroller system for target controlled infusion].

    Science.gov (United States)

    Cheng, Yu-Ke; Zhang, Xin-An; Zhang, Yan-Wu; Wu, Qun-Ling; Dou, Jian-Hong; Wang, Rou-Shong

    2005-05-01

    This paper present a microcontroller system for target controlled infusion according to pharmacodynamic parameters of intravenous anesthetics. It can control the depth of anesthesia by adjusting the level of plasma concentrations. The system has the advantages of high precision, extended function and easy operation. It has been now used in the clinical anesthesia.

  10. Test report - 241-AN-274 Caustic Pump Control Building

    Energy Technology Data Exchange (ETDEWEB)

    Paintner, G.P.

    1995-05-01

    This Acceptance Test Report documents the test results of test procedure WHC-SD-WM-ATP-135 `Acceptance Test Procedure for the 241-AN- 274 Caustic Pump Control Building.` The objective of the test was to verify that the 241-AN-274 Caustic Pump Control Building functions properly based on design specifications per applicable H-2-85573 drawings and associated ECN`s. The objective of the test was met.

  11. Sliding mode controller for a photovoltaic pumping system

    Science.gov (United States)

    ElOugli, A.; Miqoi, S.; Boutouba, M.; Tidhaf, B.

    2017-03-01

    In this paper, a sliding mode control scheme (SMC) for maximum power point tracking controller for a photovoltaic pumping system, is proposed. The main goal is to maximize the flow rate for a water pump, by forcing the photovoltaic system to operate in its MPP, to obtain the maximum power that a PV system can deliver.And this, through the intermediary of a sliding mode controller to track and control the MPP by overcoming the power oscillation around the operating point, which appears in most implemented MPPT techniques. The sliding mode control approach is recognized as one of the efficient and powerful tools for nonlinear systems under uncertainty conditions.The proposed controller with photovoltaic pumping system is designed and simulated using MATLAB/SIMULINK environment. In addition, to evaluate its performances, a classical MPPT algorithm using perturb and observe (P&O) has been used for the same system to compare to our controller. Simulation results are shown.

  12. Condition monitoring, diagnostic and controlling tool for boiler feed pump

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Sohail [Siemens AG, Muelheim (Germany). Energy Sector; Leithner, Reinhard; Kosyna, Guenter [TU Braunschweig (Germany)

    2010-07-01

    The boiler feed pump is an important component of a thermal power generation cycle and demands high safety and unquestionable availability for flexible power plant operation. In this research paper, the methodology of a general purpose condition monitoring, diagnostic and controlling tool is presented, which can address the challenges of operational safety and availability as well as optimal operation of a boiler feed pump. This tool not only effectively records the life time consumption of both casings and rotors and monitors the small gaps between casings and rotors but also suggests appropriate actions in order to ensure that the pump operates within the allowable design limits. (orig.)

  13. Optimizing pain control through the use of implantable pumps

    Directory of Open Access Journals (Sweden)

    Boris Todoroff

    2008-10-01

    Full Text Available Wilfried Ilias1, Boris Todoroff21Dept Anesthesiology, Intensive Care Medicine and Pain Therapy, Academic Teaching Hospital St. John of God, Vienna, Austria; 2Dept. Plastic and Reconstructive Surgery, Hospital of St. Vincent, Vienna, AustriaAbstract: Intrathecal therapy represents an effective and well established treatment of nonmalignant as well as malignant pain. Devices available include mechanical constant flow pumps as well as electronic variable flow pumps with patient-controlled bolus release. The latter provide faster dose finding, individual pain control, and good acceptance by patients. New technologies such as membrane pumps and rechargeable devices are expected to be developed to clinical perfection. The available drugs for intrathecal therapy are listed according to the polyanalgesic consensus on intrathecal therapy. The integration of remote patient-controlled analgesia into electronic implantable devices, and the peptide analgesic ziconotide, have significantly improved intrathecal therapy. Complications include infections, catheter ruptures or disconnections, catheter granulomas, and technical dysfunctions. Further possibilities for optimizing intrathecal therapy include development of new drugs, drug side effects, catheter and pump technologies, and surgical techniques.Keywords: intrathecal therapy, implantable pumps, morphine pumps, intrathecal drugs, intrathecal catheters, intrathecal pain control

  14. Development of a Mechatronic Syringe Pump to Control Fluid Flow in a Microfluidic Device Based on Polyimide Film

    Science.gov (United States)

    Sek Tee, Kian; Sharil Saripan, Muhammad; Yap, Hiung Yin; Fhong Soon, Chin

    2017-08-01

    With the advancement in microfluidic technology, fluid flow control for syringe pump is always essential. In this paper, a mechatronic syringe pump will be developed and customized to control the fluid flow in a poly-dimethylsiloxane (PDMS) microfluidic device based on a polyimide laminating film. The syringe pump is designed to drive fluid with flow rates of 100 and 1000 μl/min which intended to drive continuous fluid in a polyimide based microfluidic device. The electronic system consists of an Arduino microcontroller board and a uni-polar stepper motor. In the system, the uni-polar stepper motor was coupled to a linear slider attached to the plunger of a syringe pump. As the motor rotates, the plunger pumps the liquid out of the syringe. The accuracy of the fluid flow rate was determined by adjusting the number of micro-step/revolution to drive the stepper motor to infuse fluid into the microfluidic device. With the precise control of the electronic system, the syringe pump could accurately inject fluid volume at 100 and 1000 μl/min into a microfluidic device.

  15. Quality Control and Testing Methods of Infusion Apparatus%输液设备的质量控制和检测方法

    Institute of Scientific and Technical Information of China (English)

    侯明扬

    2014-01-01

    根据输液设备质量检测规范,利用FULK测量设备分别对输液泵和注射泵的外观、流量、阻塞报警压力阈值、监测与报警系统进行检测,并对各个参数的检测方法与标准做了详细介绍,为医学工程人员进行输液设备的质控工作提供参考。%According to the quality inspection speciifcations of infusion apparatus, the appearance, lfow, pressure threshold value of blocking alarm and monitoring and alarm system of infusion pump and injection pump were tested by using FULK measuring equipment. This paper also introduced the testing methods and standards of various parameters in order to provide reference information for medical engineering staff to improve the quality control of infusion apparatus.

  16. Pump-Controlled Modal Interactions in Microdisk Lasers

    CERN Document Server

    Liew, Seng Fatt; Redding, Brandon; Solomon, Glenn S; Cao, Hui

    2014-01-01

    We demonstrate an effective control of nonlinear interactions of lasing modes in a semiconductor microdisk cavity by shaping the pump profile. A target mode is selected at the expense of its competing modes either by increasing their lasing thresholds or suppressing their power slopes above the lasing threshold. Despite of strong spatial overlap of the lasing modes at the disk boundary, adaptive pumping enables an efficient selection of any lasing mode to be the dominant one, leading to a switch of lasing frequency. The theoretical analysis illustrates both linear and nonlinear effects of selective pumping, and quantify their contributions to lasing mode selection. This work shows that adaptive pumping not only provides a powerful tool of controlling the nonlinear process in multimode lasers, but also enables the tuning of lasing characteristic after the lasers have been fabricated.

  17. Mold Heating and Cooling Pump Package Operator Interface Controls Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Josh A. Salmond

    2009-08-07

    The modernization of the Mold Heating and Cooling Pump Package Operator Interface (MHC PP OI) consisted of upgrading the antiquated single board computer with a proprietary operating system to off-the-shelf hardware and off-the-shelf software with customizable software options. The pump package is the machine interface between a central heating and cooling system that pumps heat transfer fluid through an injection or compression mold base on a local plastic molding machine. The operator interface provides the intelligent means of controlling this pumping process. Strict temperature control of a mold allows the production of high quality parts with tight tolerances and low residual stresses. The products fabricated are used on multiple programs.

  18. Absorption Cycle Heat Pump Model for Control Design

    DEFF Research Database (Denmark)

    Vinther, Kasper; Just Nielsen, Rene; Nielsen, Kirsten Mølgaard

    2015-01-01

    Heat pumps have recently received increasing interest due to green energy initiatives and increasing energy prices. In this paper, a nonlinear dynamic model of a single-effect LiBr-water absorption cycle heat pump is derived for simulation and control design purposes. The model is based...... on an actual heat pump located at a larger district heating plant. The model is implemented in Modelica and is based on energy and mass balances, together with thermodynamic property functions for LiBr and water and staggered grid representations for heat exchangers. Model parameters have been fitted...... to operational data and different scenarios are simulated to investigate the operational stability of the heat pump. Finally, this paper provides suggestions and examples of derivation of lower order linear models for control design. © Copyright IEEE - All rights reserved....

  19. Control characteristics for heating system circulation pumps; Regelkennlinien fuer Heizungsumwaelzpumpen

    Energy Technology Data Exchange (ETDEWEB)

    Kallesoe, C. S.; Bidstrup, N.; Bayer, M.

    2009-07-01

    This article takes a look at variable speed circulation pumps for space heating systems that are used in one and two-family housing. Although the control systems in most houses usually have just one characteristic, the need for several control characteristics in order to cope with varying needs is discussed. The basics of finding out what the control characteristic should look like in a particular case are discussed. Modern circulation pumps with integrated speed control and their interplay with thermostatic valves are examined and discussed. A new automatic adaptation algorithm is described and its way of working is explained. Experience gained in practice is examined.

  20. Model-based drug administration : current status of target-controlled infusion and closed-loop control

    NARCIS (Netherlands)

    Kuizenga, Merel H.; Vereecke, Hugo E. M.; Struys, Michel M. R. F.

    2016-01-01

    Purpose of review Drug administration might be optimized by incorporating pharmacokinetic-dynamic (PK/PD) principles and control engineering theories. This review gives an update of the actual status of target-controlled infusion (TCI) and closed-loop computer-controlled drug administration and the

  1. Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea.

    Science.gov (United States)

    Traxdorf, Maximilian; Tschaikowsky, Klaus; Scherl, Claudia; Bauer, Judith; Iro, Heinrich; Angerer, Florian

    2016-12-06

    The aim of this study was to establish a standardized protocol for drug-induced sleep endoscopy (DISE) to differentiate obstruction patterns in obstructive sleep apnea (OSA). Target-controlled infusion (TCI) of the sedative propofol was combined with real-time monitoring of the depth of sedation using bispectral analysis. In an observational study 57 patients (mean age 44.8 years, ± SD 10.5; mean apnea hypopnea Index (AHI) 30.8/hr, ± SD 21.6, mean BMI 28.2 kg/m(2), ± SD 5.3) underwent cardiorespiratory polysomnography followed by DISE with TCI and bispectral analysis. Sleep was induced solely by the intravenous infusion of propofol with a TCI-pump, with an initial target plasma level of 2.0 µg/ml. Under continuous monitoring of the patient's respiration, state of consciousness and value of the bispectral analysis, the target plasma propofol level was raised in steps of 0.2 µg/ml/2 min until the desired depth of sedation was reached. The mean value of the bispectral analysis at the target depth of sedation was determined and the obstruction patterns during DISE-TCI-bispectral analysis then classified according to the VOTE-system. Subsequently the results were analyzed according to polysomnographic and anthropometric data. The occurrence of multilevel obstruction sites across all degrees of severity of OSA clarifies the need for sleep endoscopy prior to upper airway surgery. The advantage of this technique is the reproducibility of the protocol even for heterogeneous groups of patients. In addition, the gradual controlled and standardized increase of the plasma level of propofol with real-time control of the bispectral index leads to a precisely controllable depth of sedation. The DISE-TCI-bispectral analysis procedure is a step towards a required reproducible protocol of sleep endoscopy - capable of standardization. However it is not yet known whether these observed obstruction patterns also correspond to findings in natural sleep.

  2. Polypyrrole-Based Implantable Electroactive Pump for Controlled Drug Microinjection.

    Science.gov (United States)

    Yan, Bingxi; Li, Boyi; Kunecke, Forest; Gu, Zhen; Guo, Liang

    2015-07-15

    Implantable devices for long-lasting controlled insulin microinjection are of great value to diabetic patients. To address this need, we develop a flexible electroactive pump based on a biocompatible polypyrrole composite film that comprises a polypyrrole matrix and a macromolecular dopant of polycaprolactone-block-polytetrahydrofuran-block-polycaprolactone. Using phosphate-buffered saline as the electrolyte, this film demonstrates much higher electroactivity and reproducibility than conventional Cl--doped polypyrrole, making it an excellent actuator for driving an implantable pump. At a driving current density of 1 mA/cm2, the pump demonstrates a consistent output capacity of 10.5 at 0.35 μL/s over 20 cycles. This work paves the way for the development of an implantable electroactive pump to improve the quality of life of diabetics.

  3. Glycemic control in cardiac surgery: implementing an evidence-based insulin infusion protocol.

    Science.gov (United States)

    Hargraves, Joelle D

    2014-05-01

    Acute hyperglycemia following cardiac surgery increases the risk of deep sternal wound infection, significant early morbidity, and mortality. Insulin infusion protocols that target tight glycemic control to treat hyperglycemia have been linked to hypoglycemia and increased mortality. Recently published studies examining glycemic control in critical illness and clinical practice guidelines from professional organizations support moderate glycemic control. To measure critical care nurses' knowledge of glycemic control in cardiac surgery before and after education. To evaluate the safety and effectiveness of an evidence-based insulin infusion protocol targeting moderate glycemic control in cardiac surgery patients. This evidence-based practice change was implemented in the cardiovascular unit in a community teaching hospital. Nurses completed a self-developed questionnaire to measure knowledge of glycemic control. Blood glucose data, collected (retrospectively) from anesthesia end time through 11:59 PM on postoperative day 2, were compared from 2 months before to 2 months after the practice change. Nurses' knowledge (test scores) increased significantly after education (pretest mean = 53.10, SD = 11.75; posttest mean = 79.10, SD = 12.02; t54 = -8.18, P nurses' knowledge of glycemic control and implementing an insulin infusion protocol targeting moderate glycemic control were effective for treating acute hyperglycemia following cardiac surgery with decreased incidence of hypoglycemia.

  4. Lower dose basal insulin infusion has positive effect on glycaemic control for children with type I diabetes on continuous subcutaneous insulin infusion therapy

    NARCIS (Netherlands)

    Schulten, Ron J; Piet, Jessica; Bruijning-Verhagen, Patricia; de Waal, Wouter J

    2017-01-01

    Objective: The aim of our study was to explore a possible relationship between proportion of basal insulin dose (%BD/T) and glycaemic control in children with type I diabetes on continuous subcutaneous insulin infusion (CSII) therapy. Methods: All patients under the age of 18 with type I diabetes

  5. Analysis of Decentralized Control for Absorption Cycle Heat Pumps

    DEFF Research Database (Denmark)

    Vinther, Kasper; Just Nielsen, Rene; Nielsen, Kirsten Mølgaard

    2015-01-01

    Email Print Request Permissions This paper investigates decentralized control structures for absorption cycle heat pumps and a dynamic nonlinear model of a single-effect LiBr-water absorption system is used as case study. The model has four controllable inputs, which can be used to stabilize...... the operation of the heat pump under different load conditions. Different feasible input-output pairings are analyzed by computation of relative gain array matrices and scaled condition numbers, which indicate the best pairing choice and the potential of each input-output set. Further, it is possible...... to minimize the effect of cross couplings and improve stability with the right pairing of input and output. Simulation of selected candidate input-output pairings demonstrate that decentralized control can provide stable operation of the heat pump....

  6. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  7. Electrically controllable spin pumping in graphene via rotating magnetization

    Science.gov (United States)

    Rahimi, Mojtaba A.; Moghaddam, Ali G.

    2015-07-01

    We investigate pure spin pumping in graphene by imposing a ferromagnet (F) with rotating magnetization on top of it. Using the generalized scattering approach for adiabatic spin pumping, we obtain the spin current pumped through magnetic graphene to the normal (N) region. This spin current which can be easily controlled by gate voltages, reaches sufficiently large values measurable in current experimental setups. The spin current reaches its maximum when one of the spins is completely filtered because of its vanishing density of states in the ferromagnetic part. In order to study the effect of the ferromagnetic part length on the pumped spin current, the N—F—N structure is considered. It is found that in contrast to the metallic ferromagnetic materials the transverse spin coherence length can be comparable to the length of F. Subsequently, due to the quantum interferences inside the middle F region, the spin current becomes an oscillatory function of JL/\\hbar {{v}\\text{F}} in which J is the spin splitting and L is the length of F. Finally controllability of the pumped spin into two different normal sides in the N—F—N hybrid device gives rise to the spin battery effect.

  8. [Target-controlled propofol infusion for general anesthesia in three obese patients].

    Science.gov (United States)

    Kakinohana, M; Tomiyama, H; Matsuda, S; Okuda, Y

    2000-07-01

    We report three cases in which the target-controlled propofol infusion technique was used in obese patients for general anesthesia. General anesthesia was induced by intravenous administration of fentanyl 150-300 micrograms and ketamine 50-80 mg and propofol 2 micrograms.ml-1 to achieve a target blood concentration by target-controlled infusion system. Anesthetic maintenance was achieved by ketamine 1 mg.kg-1.h-1 for 1 hour after the induction, propofol at target blood concentration of 2-3.5 micrograms.ml-1 and the intermittent epidural injection of 1.5% lidocaine through an epidural catheter. The surgical procedures were uneventful. The estimated blood concentrations of propofol at emergence from anesthesia calculated by ConGrace ranged from 1.49-1.69 micrograms.ml-1, and it took 230-300 seconds to emerge from anesthesia. The target-controlled propofol infusion technique appears useful to control the depth of anesthesia in obese patients.

  9. Factors associated with glycemic control in adult type 1 diabetes patients treated with insulin pump therapy.

    Science.gov (United States)

    Matejko, Bartłomiej; Skupien, Jan; Mrozińska, Sandra; Grzanka, Małgorzata; Cyganek, Katarzyna; Kiec-Wilk, Beata; Malecki, Maciej T; Klupa, Tomasz

    2015-02-01

    Continuous subcutaneous insulin infusion (CSII) by insulin pump seems to improve glycemia and quality of life as compared to conventional insulin therapy in type 1 diabetes (T1DM). However, while many T1DM subjects achieve excellent glycemic control, some others cannot reach recommended goals. In a retrospective analysis, we searched for factors associated with glycemic control in T1DM patients treated with insulin pump therapy. Data from 192 patients (133 women and 59 men) treated with personal insulin pumps at the Department of Metabolic Diseases, University Hospital, Krakow, Poland were analyzed. Sources of information included medical records, memory read-outs from insulin pumps and data from glucose meters. Univariate, multivariate linear and logistic regression analysis for the association with hemoglobin A1c (HbA1c) level were performed. The mean age of the subjects was 28.9 (±11.2) years, the mean duration of T1DM-14.6 (±7.6) years, mean body mass index-23.5 (±3.1) kg/m2. The mean HbA1c level in the entire study group was 7.4% (57 mmol/mol). In the multivariate linear regression analysis, HbA1c correlated with the mean number of daily blood glucose measurements, number of hypoglycemic episodes per 100 blood glucose measurements, age at the examination, and continuous glucose monitoring system use. Multivariate logistic regression analysis for reaching the therapeutic target of HbA1cpump-treated T1DM subjects.

  10. Usability Evaluation of Infusion Pump Based on System Usability Scale%基于系统可用性量表的输液泵可用性评估

    Institute of Scientific and Technical Information of China (English)

    严毅; 王国宏; 刘胜林; 吴汉曦; 张强

    2012-01-01

    Objective To evaluate the usability of 3 kinds of infusion pumps in clinical. Methods System usability scale(SUS) is used to investigate the usability evaluation of clinical nurses to infusion pumps. Results There is a significant statistical difference about usability among 3 kinds of infusion pumps. The usability of brand 1 is better than the other two. No significant statistical difference of usability is found between brand 2 and 3. Conclusion SUS is useful and efficient for evaluating the usability of infusion pumps.%目的 评估三款输液泵的临床可用性.方法 采用系统可用性量表(SUS),调查临床护士对输液泵的使用评价.结果 三种输液泵可用性具有差异(P<0.05),品牌1可用性优于品牌2与品牌3,品牌2与品牌3可用性无明显差异.结论 SUS可以有效地用于输液泵的临床可用性评估中.

  11. System control fuzzy neural sewage pumping stations using genetic algorithms

    Directory of Open Access Journals (Sweden)

    Владлен Николаевич Кузнецов

    2015-06-01

    Full Text Available It is considered the system of management of sewage pumping station with regulators based on a neuron network with fuzzy logic. Linguistic rules for the controller based on fuzzy logic, maintaining the level of effluent in the receiving tank within the prescribed limits are developed. The use of genetic algorithms for neuron network training is shown.

  12. Decant pump assembly and controls qualification testing - test report

    Energy Technology Data Exchange (ETDEWEB)

    Staehr, T.W., Westinghouse Hanford

    1996-05-02

    This report summarizes the results of the qualification testing of the supernate decant pump and controls system to be used for in-tank sludge washing in aging waste tank AZ-101. The test was successful and all components are qualified for installation and use in the tank.

  13. Metabolic Control with Insulin Pump Therapy: Preliminary Experience

    Directory of Open Access Journals (Sweden)

    Shang-Ren Hsu

    2008-07-01

    Conclusion: Our preliminary experience demonstrated the effectiveness of insulin pump therapy for both type 1 and type 2 diabetic patients. The reduction in their HbA1C values was both statistically and clinically significant. This treatment should be considered for patients poorly controlled by subcutaneous insulin injection therapy.

  14. Controlling double ionization of atoms in pump-probe experiments

    CERN Document Server

    Bauch, S; Bonitz, M

    2010-01-01

    The ionization dynamics of a two-electron atom in an attosecond XUV-infrared pump-probe experiment is simulated by solving the time-dependent two-electron Schr\\"odinger equation. A dramatic change of the double ionization (DI) yield with variation of the pump-probe delay is reported and the governing role of electron-electron correlations is shown. The results allow for a direct control of the DI yield and of the relative strength of double and single ionization.

  15. Computer-controlled positive displacement pump for physiological flow simulation.

    Science.gov (United States)

    Holdsworth, D W; Rickey, D W; Drangova, M; Miller, D J; Fenster, A

    1991-11-01

    A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the production of nearly uninterrupted steady flow, as well as a variety of pulsatile waveforms, including waveforms with reverse flow. The capabilities of this pump to produce steady flow from 0.1 to 60 ml s-1, as well as sinusoidal flow and physiological flow, such as that found in the common femoral and common carotid arteries are demonstrated. Cycle-to-cycle reproducibility is very good, with an average variation of 0.1 ml s-1 over thousands of cycles.

  16. Impact of insulin pumps on glycaemic control in a pump-naïve paediatric regional population.

    Science.gov (United States)

    de Bock, Martin; Gunn, Alistair Jan; Holt, Jean-Ann; Derraik, José G B; Reed, Peter; Cutfield, Wayne; Mouat, Fran; Hofman, Paul; Jefferies, Craig

    2012-03-01

    To examine the clinical impact of insulin-pump therapy for children with type 1 diabetes mellitus (T1DM) in a regional paediatric service, Auckland, New Zealand. Retrospective analysis of children with T1DM from the Starship paediatric diabetes database who started on insulin-pump therapy from 2002 to 2008 compared with the whole T1DM population and with an equal number of non-pump patients matched by age, sex, ethnicity and duration of diabetes. From 621 subjects with 6680 clinic visits, 75 children were treated with insulin-pump therapy for more than 12 months. Transitioning to insulin-pump treatment was associated with an improvement in HbA1c compared with baseline (-0.3%/year, P pump controls showed a continuing trend to higher HbA1C values (+0.2%/year, P pump start (from 27 (0-223) to 5 (0-0.91) events/100 patient years) with no change in non-pump controls; the rate of diabetic ketoacidosis remained low in both groups. In a pump-naïve regional paediatric population, insulin-pump therapy for T1DM was safe and effective, and associated with sustained improvements in HbA1c and lower risk of hypoglycaemia. © 2011 The Authors. Journal of Paediatrics and Child Health © 2011 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  17. A Novel Technique for Split-Thickness Skin Donor Site Pain Control: Subcutaneous Catheters for Continuous Local Anesthetic Infusion

    Science.gov (United States)

    2012-01-01

    has been described after laparotomy, tho- racotomy, inguinal hernia repair, and rib fractures.2–4 We describe our experience at the U.S. Army Insti... complications (one catheter insertion site infection and one early catheter discontinuation due to poor skin fixation). This report is limited by its...Sanchez B, Waxman K, Tatevossian R, Gamberdella M, Read B. Local anesthetic infusion pumps improve postoperative pain after inguinal hernia repair: a

  18. Propofol-controlled infusion technique in assessing the safe dosage for sedation during epidural anesthesia

    Institute of Scientific and Technical Information of China (English)

    Yingmin Cai; Pengbin Liu; Jinxin Song; Rongliang Xue

    2006-01-01

    BACKGROUND:Epidural anesthesia requires a convenient and accurate method to determine the plasma concentration of the given subsidiary drug.The target-controlled infusion(TCI)technique,controlling infusion pump by computer,has been used.Intravenous jnjection of propofol was given for the purpose of measunng plasma concentrations and to observe the effects of different target concentrations on the memory,consciousness,hemodynamics and blood gases of patients,in order to find a safe dosage for sedation in epidural anesthesia.OBJECTIVE:To observe the influence of different target concentrations on the memory,consciousness,hemodynamics and blood gases of patients accepted epiduml anesthesia.DESIGN:A randomized and controlled study.SETTING:Department of Anesthesiology,the Second Affiliated Hospital,Medical College of Xi'an Jiao Tong University.PARTICIPANTS:The expenment was conducted in the Department of Anesthesiology,the Second Affiliated Hospital,Medical College of Xi'an Jiao Tong University from June 2005 to June 2006.Fifty patients underwent surgery for lower abdomen and lower limbs were selected,including 30 males and 20 females,30-60 years old with an average of(46±6)years,weighling(65.8±8.5)kg,and American Society of Anesthesiology(ASA)gradling of Ⅰ-Ⅱ.All the patients were informed and agreed with the items for detection.METHODS:All the patients were given diazepam(10 mg)and atropine(0.5 mg)intramusculady 30 minutes before surgery.They were placed supinely and given oxygen inhalation,their blood pressure,heart rate and blood oxygen saturation were determined,then an epidural puncture was made in the left lateral decubitus position with hands crossed over knees.The patients were in a horizontal position and a radial artery puncture was done,after the epidural cathetar was positioned into epidural space.Blood of radial artery was drawn to get a blood gas,a linked HP multi-functional monitor was used to monitor blood pressure(radial artery

  19. Drug-induced sleep endoscopy: conventional versus target controlled infusion techniques--a randomized controlled study.

    Science.gov (United States)

    De Vito, Andrea; Agnoletti, Vanni; Berrettini, Stefano; Piraccini, Emanuele; Criscuolo, Armando; Corso, Ruggero; Campanini, Aldo; Gambale, Giorgio; Vicini, Claudio

    2011-03-01

    Understanding the sites of pharyngeal collapse is mandatory for surgical treatment decision-making in obstructive sleep-apnea-hypopnea syndrome patients. Drug-induced sleep endoscopy (DISE) allows for the direct observation of the upper airway during sedative-induced sleep. In order to re-create snoring and apnea patterns related to a spontaneous sleep situation, the authors used a target-controlled infusion (TCI) sleep endoscopy (DISE-TCI), comparing this technique to conventional DISE, in which sedation was reached by a manual bolus injection. The authors conducted a prospective, randomized, unicenter study. The apneic event observation and its correlation with pharyngeal collapse patterns is the primary endpoint; secondary endpoints are defined as stability and safety of sedation plans of DISE-TCI technique. From January 2009 to June 2009, 40 OSAHS patients were included in the study and randomized allocated in two groups: the bolus injection conventional DISE group and the DISE-TCI group. We recorded the complete apnea event at the oropharynx and hypopharynx levels in 4 patients of the conventional DISE group (20%) and in 17 patients of the DISE-TCI group (85%) (P DISE group because of severe desaturation that resulted from the first bolus of propofol (1 mg/kg) (P = 0.4872 ns). We recorded the instability of the sedation plan in 13 patients from the conventional DISE group (65%) and 1 patient from the DISE-TCI group (5%) (P = 0.0001). Our results suggest that the DISE-TCI technique should be the first choice in performing sleep endoscopy because of its increased accuracy, stability and safety.

  20. Lifting gate polydimethylsiloxane microvalves and pumps for microfluidic control.

    Science.gov (United States)

    Kim, Jungkyu; Kang, Minjee; Jensen, Erik C; Mathies, Richard A

    2012-02-21

    We describe the development and characterization of pneumatically actuated "lifting gate" microvalves and pumps. A fluidic layer containing the gate structure and a pneumatic layer are fabricated by soft-lithography in PDMS and bonded permanently with an oxygen plasma treatment. The microvalve structures are then reversibly bonded to a featureless glass or plastic substrate to form hybrid glass-PDMS and plastic-PDMS microchannel structures. The break-through pressures of the microvalve increase linearly up to 65 kPa as the closing pressure increases. The pumping capability of these structures ranges from the nanoliter to microliter scale depending on the number of cycles and closing pressure employed. The micropump structures exhibit up to 86.2% pumping efficiency from flow rate measurements. The utility of these structures for integrated sample processing is demonstrated by performing an automated immunoassay. These lifting gate valve and pump structures enable facile integration of complex microfluidic control systems with a wide range of lab-on-a-chip substrates.

  1. Impact of infusion method on amikacin serum levels in humans.

    Science.gov (United States)

    Simon, N; Décaudin, B; Lannoy, D; Odou, M F; De Broucker, M; Barthélémy, C; Poret, E; Dubreuil, L; Odou, P

    2010-08-01

    Aminoglycosides are broad-spectrum antibiotics with peak-dependent bactericidal activity, administered by gravity infusion or for more accuracy by electronic pump infusion. The aim of this study was to assess the difference between the two systems and its pharmacokinetic impact. Twenty-four patients hospitalised for community-acquired pulmonary infections received amikacin by IV route over 1 h with a targeted peak concentration of 35 mg/L. They were randomly distributed into two groups, one receiving infusion through a pump system, the other by gravity. Amikacin serum levels were determined at the end of infusion and 24 h later. C(max) values were significantly lower with gravity than pump (40.2 +/- 12.3 vs. 50.6 +/- 17.6 mg/L, respectively; p = 0.04). Elimination half-life time, volume of distribution and clearance did not differ significantly from one group to the other. The percentage of patients who failed to achieve the targeted peak concentration was significantly higher with gravity than pump (41.7% vs. 16.7%, respectively; p infusion flow-rate provides better control over amikacin C(max). This study underlines the fact that infusion device characteristics should be added to the physiopathological information of a patient if we are to make a better estimation of pharmacokinetic parameters.

  2. Assessment of use of specific features of subcutaneous insulin infusion systems and their relationship to metabolic control in patients with type 1 diabetes.

    Science.gov (United States)

    Quirós, Carmen; Patrascioiu, Ioana; Giménez, Marga; Vinagre, Irene; Vidal, Mercè; Jansà, Margarita; Conget, Ignacio

    2014-01-01

    Patients with type 1 diabetes (T1DM) treated with continuous subcutaneous insulin infusion (CSII) have available several specific features of these devices. The aim of this study was to evaluate the relationship between real use of them and the degree of glycemic control in patients using this therapy. Forty-four T1DM patients on CSII therapy with or without real-time continuous glucose monitoring (CGM) were included. Data from 14 consecutive days were retrospectively collected using the therapy management software CareLink Personal/Pro(®) and HbA1c measurement performed at that period. The relationship between the frequency of usie of specific features of insulin pumps (non-sensor augmented or sensor-augmented) and glycemic control was analyzed. Mean HbA1c in the group was 7.5 ± .8%. Mean daily number of boluses administered was 5.1 ± 1.8, with 75.4% of them being bolus wizards (BW). Daily number of boluses was significantly greater in patients with HbA1c 7.5% (5.3 ± 1.6 vs. 4.3 ± 1.6, P=.056). There was a trend to greater use of BW in patients with better control (82.8 ± 21.4% vs. 69.9 ± 29.1%, P=.106). HbA1c was lower in patients using CGM (n=8) as compared to those not using sensor-augmented pumps (7.6 ± .8 vs 7.1 ± .7, P=.067), but the difference was not statistically significant. More frequent use of BW appears to be associated to better metabolic control in patients with T1DM using pump therapy. In standard clinical practice, augmentation of insulin pump with CGM may be associated to improved glycemic control. Copyright © 2013 SEEN. Published by Elsevier Espana. All rights reserved.

  3. Continuous intraperitoneal insulin infusion in patients with 'brittle' diabetes

    DEFF Research Database (Denmark)

    DeVries, J H; Eskes, S A; Snoek, Frank J

    2002-01-01

    AIMS: To evaluate the effects of continuous intraperitoneal insulin infusion (CIPII) using implantable pumps on glycaemic control and duration of hospital stay in poorly controlled 'brittle' Dutch diabetes patients, and to assess their current quality of life. METHODS: Thirty-three patients were...

  4. Feasibility of bispectral index-guided propofol infusion for flexible bronchoscopy sedation: a randomized controlled trial.

    Directory of Open Access Journals (Sweden)

    Yu-Lun Lo

    Full Text Available OBJECTIVES: There are safety issues associated with propofol use for flexible bronchoscopy (FB. The bispectral index (BIS correlates well with the level of consciousness. The aim of this study was to show that BIS-guided propofol infusion is safe and may provide better sedation, benefiting the patients and bronchoscopists. METHODS: After administering alfentanil bolus, 500 patients were randomized to either propofol infusion titrated to a BIS level of 65-75 (study group or incremental midazolam bolus based on clinical judgment to achieve moderate sedation. The primary endpoint was safety, while the secondary endpoints were recovery time, patient tolerance, and cooperation. RESULTS: The proportion of patients with hypoxemia or hypotensive events were not different in the 2 groups (study vs. control groups: 39.9% vs. 35.7%, p = 0.340; 7.4% vs. 4.4%, p = 0.159, respectively. The mean lowest blood pressure was lower in the study group. Logistic regression revealed male gender, higher American Society of Anesthesiologists physical status, and electrocautery were associated with hypoxemia, whereas lower propofol dose for induction was associated with hypotension in the study group. The study group had better global tolerance (p<0.001, less procedural interference by movement or cough (13.6% vs. 36.1%, p<0.001; 30.0% vs. 44.2%, p = 0.001, respectively, and shorter time to orientation and ambulation (11.7±10.2 min vs. 29.7±26.8 min, p<0.001; 30.0±18.2 min vs. 55.7±40.6 min, p<0.001, respectively compared to the control group. CONCLUSIONS: BIS-guided propofol infusion combined with alfentanil for FB sedation provides excellent patient tolerance, with fast recovery and less procedure interference. TRIAL REGISTRATION: ClinicalTrials. gov NCT00789815.

  5. Study of Cisatracurium and Sufentanil Consumption Using a Closed Loop Computer Control Infusion System

    Science.gov (United States)

    2013-02-06

    The Intraoperative Effect of Dexmedetomidine on Cisatracurium Infusion Consumption and Its Recovery Index.; Effect of Dexmedetomidine on Sufentanil Consumption.; Quantitative Analysis of Cisatracurium Infusion Requirements, Sufentanil Consumption and Recovery Index in Different Age Groups.

  6. Centrifugal pump and roller pump in adult cardiac surgery: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Saczkowski, Richard; Maklin, Michelle; Mesana, Thierry; Boodhwani, Munir; Ruel, Marc

    2012-08-01

    Centrifugal pump (CP) and roller pump (RP) designs are the dominant main arterial pumps used in cardiopulmonary bypass (CPB). Trials reporting clinical outcome measures comparing CP and RP are controversial. Therefore, a meta-analysis was undertaken to evaluate clinical variables from randomized controlled trials (RCTs). Keyword searches were performed on Medline (1966-2011), EmBase (1980-2011), and CINAHL (1981-2011) for studies comparing RP and CP as the main arterial pump in adult CPB. Pooled fixed-effects estimates for dichotomous and continuous data were calculated as an odds ratio and weighted-mean difference, respectively. The P value was utilized to assess statistical significance (P pump-related malfunction or mishap. The meta-analysis of RCTs comparing CP and RP in adult cardiac surgery suggests no significant difference for hematological variables, postoperative blood loss, transfusions, neurological outcomes, or mortality.

  7. Control System for Solar-Assisted Heat Pump System.

    Science.gov (United States)

    heat pump , a water-to-air heat exchanger, a domestic water heater, and a cooling tower. The preferred embodiment of the controller of the present invention includes a first temperature sensing means for sensing the temperature of the collector fluid at the outlet of the solar collector system, a second temperature sensing means for sensing the temperature of the storage fluid at the thermal storage system, and a third temperature sensing means for sensing the temperature of the inlet water to the domestic water heater. The controller compares the temperature of the thermal

  8. Evaluation of SLOG/TCI-III pediatric system on target control infusion of propofol.

    Science.gov (United States)

    Yang, Wan-hua; Gu, Hong-bin; Chen, Bing; Li, Juan; Fan, Qiu-wei; Yuan, Yong-fang; Wang, Xiangdong

    2011-11-01

    The target-controlled infusion-III (SLOG/TCI-III) system was derived from a model set up by the local pediatric population for target control infusion of propofol. The current study aimed at evaluating the difference between target concentrations of propofol and performance, which was measured using the SLOG/TCI-III system in children. Thirty children fulfilling the I-II criteria according to American Society of Anesthesiology were enrolled in the study. The target plasma concentration of propofol was fed into the SLOG/TCI-III system and compared with the measured concentrations of propofol. Blood samples were collected and analyzed by high performance liquid chromatography with fluorescence detector. The performance error (PE) was determined for each measured blood propofol concentration. The performances of the TCI-III system were determined by the median performance error (MDPE), the median absolute performance error (MDAPE), and Wobble (the median absolute deviation of each PE from the MDPE), respectively. Concentration against target concentration showed good linear correlation: concentration = 1.3428 target concentration - 0.2633 (r = 0.8667). The MDPE and MDAPE of the pediatric system were 10 and 22%, respectively, and the median value for Wobble was 24%. MDPE and MDAPE were less than 15 and 30%, respectively. The performance of TCI-III system seems to be in the accepted limits for clinical practice in children.

  9. Evaluation of SLOG/TCI-III pediatric system on target control infusion of propofol

    Directory of Open Access Journals (Sweden)

    Yang Wan-hua

    2011-11-01

    Full Text Available Abstract Background The target-controlled infusion-III (SLOG/TCI-III system was derived from a model set up by the local pediatric population for target control infusion of propofol. Methods The current study aimed at evaluating the difference between target concentrations of propofol and performance, which was measured using the SLOG/TCI-III system in children. Thirty children fulfilling the I-II criteria according to American Society of Anesthesiology were enrolled in the study. The target plasma concentration of propofol was fed into the SLOG/TCI-III system and compared with the measured concentrations of propofol. Blood samples were collected and analyzed by high performance liquid chromatography with fluorescence detector. The performance error (PE was determined for each measured blood propofol concentration. The performances of the TCI-III system were determined by the median performance error (MDPE, the median absolute performance error (MDAPE, and Wobble (the median absolute deviation of each PE from the MDPE, respectively. Results Concentration against target concentration showed good linear correlation: concentration = 1.3428 target concentration - 0.2633 (r = 0.8667. The MDPE and MDAPE of the pediatric system were 10 and 22%, respectively, and the median value for Wobble was 24%. MDPE and MDAPE were less than 15 and 30%, respectively. Conclusions The performance of TCI-III system seems to be in the accepted limits for clinical practice in children.

  10. 豚鼠耳蜗微渗透压泵慢性灌注技术的改进%Technical improvement of chronic infusion of drugs intothe guinea pig cocMea by an osmotic pump

    Institute of Scientific and Technical Information of China (English)

    杨卫平; 胡博华; 王佩英; 郭维; 姜泗长

    2001-01-01

    Objeetive:To introduce an improved technique of chronic infusion of drugs into the guinea pig cochlea using an osmotic pump. Methods: A stainless steel tube was surgically implanted into the basal turn of the guinea pig cochlea and connected to the pump. Artificial perilymphatic fluid was infused into the cochlea. Auditory brainstem responses (ABRs) and hair cell morphology were examined. Results:In eight artificial perilymphatic fluid infused cochleas, the thresholds of ABRs were kept in the normal level and no hair cell loss was found 14 days after the beginning of infusion.Conclusion:This result indicates that the improved technique perfects the method of osmotic pump implant for chronic infusion of drugs into the inner ear.%目的:介绍应用改进的微渗透压泵进行豚鼠耳蜗慢性灌注的方法。方法:将徽渗透压泵埋置于8只豚鼠背部,经固定于耳蜗底回鼓阶内的改良微导管将人工外淋巴液缓慢注入内耳,观察豚鼠耳蜗对徽渗透压泵慢性灌注人工外淋巴液的反应。结果:动物术后M d脑干诱发电反应阈值(ABR)无明显的变化,耳蜗螺旋神经节细胞及毛细胞未见损伤。结论:改进后的微渗透压泵耳蜗灌流技术完善了内耳慢性给药的实验方法。

  11. Proportional Insulin Infusion in Closed-Loop Control of Blood Glucose

    Science.gov (United States)

    Grasman, Johan

    2017-01-01

    A differential equation model is formulated that describes the dynamics of glucose concentration in blood circulation. The model accounts for the intake of food, expenditure of calories and the control of glucose levels by insulin and glucagon. These and other hormones affect the blood glucose level in various ways. In this study only main effects are taken into consideration. Moreover, by making a quasi-steady state approximation the model is reduced to a single nonlinear differential equation of which parameters are fit to data from healthy subjects. Feedback provided by insulin plays a key role in the control of the blood glucose level. Reduced β-cell function and insulin resistance may hamper this process. With the present model it is shown how by closed-loop control these defects, in an organic way, can be compensated with continuous infusion of exogenous insulin. PMID:28060898

  12. Insulin pump patient characteristics and glucose control in the hospitalized setting.

    Science.gov (United States)

    Kannan, Subramanian; Satra, Ankita; Calogeras, Ellen; Lock, Patricia; Lansang, M Cecilia

    2014-05-01

    Patients' knowledge of their insulin pumps and glucose control during hospitalization has not been studied. The aim was to study the determinants of glycemic control in patients using continuous subcutaneous insulin infusion (CSII) in the hospital. Three groups of patients were identified: those who did not need any inpatient education and continued on CSII (gorup A), those who received education then continued on CSII (group B), and those for whom CSII was not appropriate and were treated with multiple daily insulin injections (gorup C). We compared the measures of glycemic control between the 3 groups and analyzed which variables impacted glucose control. There were 50 patients, with 51 hospital admissions, 57% males, mean age 48 ± 13 years, 86% had type 1 diabetes (T1DM). The mean DM duration was 26 ± 14 years, mean duration of CSII use was 8.7 ± 6 years, and mean HbA1c was 7.6 ± 1.4%. The mean duration of hospital stay was 5.6 ± 4.6 days. Mean blood glucose (BG) and frequency of hyperglycemia and hypoglycemic events among the 3 groups adjusted for their duration of hospital stay were not statistically different. None of the patients developed diabetic ketoacidosis while using their pump. Stepwise multivariate analysis revealed knowledge of hypoglycemia correction was the single most important predictor of mean BG (P < .001). Patients who received inpatient education performed similarly to patients who did not need inpatient education. Patients who receive inpatient education on CSII fare similar as patients who did not require inpatient education. © 2014 Diabetes Technology Society.

  13. Pump/Control System Minimum Operating Cost Testing

    Science.gov (United States)

    1977-01-01

    A preliminary evaluation of pump performance was initiated to determine the efficiencies of an arbitrary group of small pumps. Trends in factors affecting energy usage in typical prime movers which might be used in liquid transport solar systems were assessed. Comparisons of centrifugal pump efficiencies were made from one manufacturer to another. Tests were also made on two positive-displacement pumps and comparisons with centrifugal pumps were observed.

  14. The control of convection by fuelling and pumping in the JET pumped divertor

    Energy Technology Data Exchange (ETDEWEB)

    Harbour, P.J.; Andrew, P.; Campbell, D.; Clement, S.; Davies, S.; Ehrenberg, J.; Erents, S.K.; Gondhalekar, A.; Gadeberg, M.; Gottardi, N.; Von Hellermann, M.; Horton, L.; Loarte, A.; Lowry, C.; Maggi, C.; McCormick, K.; O`Brien, D.; Reichle, R.; Saibene, G.; Simonini, R.; Spence, J.; Stamp, M.; Stork, D.; Taroni, A.; Vlases, G. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking

    1994-07-01

    Convection from the scrape-off layer (SOL) to the divertor will control core impurities, if it retains them in a cold, dense, divertor plasma. This implies a high impurity concentration in the divertor, low at its entrance. Particle flux into the divertor entrance can be varied systematically in JET, using the new fuelling and pumping systems. The convection ratio has been estimated for various conditions of operation. Particle convection into the divertor should increase thermal convection, decreasing thermal conduction, and temperature and density gradients along the magnetic field, hence increasing the frictional force and decreasing the thermal force on impurities. Changes in convection in the SOL, caused by gaseous fuelling, have been studied, both experimentally in the JET Mk I divertor and with EDGE2/NIMBUS. 1 ref., 4 figs., 1 tab.

  15. Adjustment of alarm of threshold value of Smith micro-medicinal infusion pump%史密斯注射泵高低阻塞报警的调整

    Institute of Scientific and Technical Information of China (English)

    张敏刚; 云庆辉

    2012-01-01

    目的:通过改变微量注射泵的阻塞报警阈值,确保临床微量注射用药的安全。方法:通过分析微量注射泵的设计得到产生阻塞报警的原理,对于不同类型的微量注射泵应用不同的调试方法,改变影响报警阈值的因素,达到改变报警阈值的目的;结果:经设备剂量检测调试后的微量注射泵95%能达到规定的安全值,极少数微量注射泵需进行不同的处理,以满足临床应用安全。结论:改变注射泵的报警影响因素可以达到改变报警阈值的目的。%Objective: To ensure the safety of the rational drug use, to change the threshold value of the micro-medicinal infusion pump. Methods: Through analyzing the principle of the micro-medicinal infusion pump produces stress, for the different type of the pump use different modify way, find the reasons of produces stress and change threshold value; Results: through change 95% the pump limens can return normal value, the others need next treat, meet clinic require. Conclusions: To change the reasons of create warning to change threshold value of micro-medicinal infusion pump.

  16. Security Risks, Low-tech User Interfaces, and Implantable Medical Devices: A Case Study with Insulin Pump Infusion Systems

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Nathanael R [ORNL; Kohno, Tadayoshi [University of Washington, Seattle

    2012-01-01

    Portable implantable medical device systems are playing a larger role in modern health care. Increasing attention is now being given to the wireless control interface of these systems. Our position is that wireless security in portable implantable medical device systems is just a part of the overall system security, and increased attention is needed to address low-tech security issues.

  17. Runaway electron beam control for longitudinally pumped metal vapor lasers

    Science.gov (United States)

    Kolbychev, G. V.; Kolbycheva, P. D.

    1995-08-01

    Physics and techniques for producing of the pulsed runaway electron beams are considered. The main obstacle for increasing electron energies in the beams is revealed to be a self- breakdown of the e-gun's gas-filled diode. Two methods to suppress the self-breakdown and enhance the volumetric discharge producing the e-beam are offered and examined. Each of them provides 1.5 fold increase of the ceiling potential on the gun. The methods also give the ways to control several guns simultaneously. Resulting in the possibility of realizing the powerful longitudinal pumping of metal-vapor lasers on self-terminated transitions of atoms or ions.

  18. Space Station Environmental Control and Life Support System Purge Control Pump Assembly Modeling and Analysis

    Science.gov (United States)

    Schunk, R. Gregory; Hunt, Patrick L. (Technical Monitor)

    2001-01-01

    Preliminary results from a thermal/flow analysis of the Purge Control Pump Assembly (PCPA) indicate that pump performance (mass flow rate) is enhanced via cooling of the housing and lowering of the inlet vapor quality. Under a nominal operational profile (25% duty cycle or less), at the maximum motor dissipation, it appears that the peristaltic tubing temperature will still remain significantly below the expected UPA condenser temperature (78 F max versus approximately 105 F in the condenser) permitting condensation in the pump head.

  19. Skeletal Muscle Pump Drives Control of Cardiovascular and Postural Systems

    Science.gov (United States)

    Verma, Ajay K.; Garg, Amanmeet; Xu, Da; Bruner, Michelle; Fazel-Rezai, Reza; Blaber, Andrew P.; Tavakolian, Kouhyar

    2017-01-01

    The causal interaction between cardio-postural-musculoskeletal systems is critical in maintaining postural stability under orthostatic challenge. The absence or reduction of such interactions could lead to fainting and falls often experienced by elderly individuals. The causal relationship between systolic blood pressure (SBP), calf electromyography (EMG), and resultant center of pressure (COPr) can quantify the behavior of cardio-postural control loop. Convergent cross mapping (CCM) is a non-linear approach to establish causality, thus, expected to decipher nonlinear causal cardio-postural-musculoskeletal interactions. Data were acquired simultaneously from young participants (25 ± 2 years, n = 18) during a 10-minute sit-to-stand test. In the young population, skeletal muscle pump was found to drive blood pressure control (EMG → SBP) as well as control the postural sway (EMG → COPr) through the significantly higher causal drive in the direction towards SBP and COPr. Furthermore, the effect of aging on muscle pump activation associated with blood pressure regulation was explored. Simultaneous EMG and SBP were acquired from elderly group (69 ± 4 years, n = 14). A significant (p = 0.002) decline in EMG → SBP causality was observed in the elderly group, compared to the young group. The results highlight the potential of causality to detect alteration in blood pressure regulation with age, thus, a potential clinical utility towards detection of fall proneness. PMID:28345674

  20. Skeletal Muscle Pump Drives Control of Cardiovascular and Postural Systems

    Science.gov (United States)

    Verma, Ajay K.; Garg, Amanmeet; Xu, Da; Bruner, Michelle; Fazel-Rezai, Reza; Blaber, Andrew P.; Tavakolian, Kouhyar

    2017-03-01

    The causal interaction between cardio-postural-musculoskeletal systems is critical in maintaining postural stability under orthostatic challenge. The absence or reduction of such interactions could lead to fainting and falls often experienced by elderly individuals. The causal relationship between systolic blood pressure (SBP), calf electromyography (EMG), and resultant center of pressure (COPr) can quantify the behavior of cardio-postural control loop. Convergent cross mapping (CCM) is a non-linear approach to establish causality, thus, expected to decipher nonlinear causal cardio-postural-musculoskeletal interactions. Data were acquired simultaneously from young participants (25 ± 2 years, n = 18) during a 10-minute sit-to-stand test. In the young population, skeletal muscle pump was found to drive blood pressure control (EMG → SBP) as well as control the postural sway (EMG → COPr) through the significantly higher causal drive in the direction towards SBP and COPr. Furthermore, the effect of aging on muscle pump activation associated with blood pressure regulation was explored. Simultaneous EMG and SBP were acquired from elderly group (69 ± 4 years, n = 14). A significant (p = 0.002) decline in EMG → SBP causality was observed in the elderly group, compared to the young group. The results highlight the potential of causality to detect alteration in blood pressure regulation with age, thus, a potential clinical utility towards detection of fall proneness.

  1. Efficacy of an Intrathecal Multidrug Infusion for Pain Control in Older Adults and in End-Stage Malignancies: A Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Sadegh Abdolmohammadi

    2015-01-01

    Full Text Available The aim of the present study was to explore the effectiveness of an alternative method to manage pain based on a time-limited intrathecal (IT infusion of an analgesic medication mixture. Three patients (69, 64 and 94 years of age with intractable and poorly controlled pain due to bed sores, pelvic metastatic mass, and thoracic vertebra and rib fractures, respectively, were treated. Daily doses of opioids could not be increased due to side effects. An IT catheter (20 G was placed by percutaneous approach in the lumbar area while advancing toward the thoracic region, and was then tunnelled and fixed subcutaneously. It was connected to an external infusion pump with a mixture of bupivacaine 1 mg/mL, naloxone 0.02 ng/mL, ketamine 100 μg/mL, morphine 0.01 mg/mL and clonidine 0.75 μg/mL. The starting rate was 1 mL/h. The pain was mostly controlled at a rate of <1 mL/h. Opioid consumption was reduced dramatically. The catheter was kept in place for one month in the first and third patients, and for six months in the second patient, until his death. Major side effects, such as hypotension, constipation, muscle weakness, sphincter dysfunction, and cognitive or mood deterioration, were not observed with this approach. One patient experienced a urinary tract infection followed by sepsis and meningitis, which was cured by antibiotics. The catheter was removed in this patient. IT infusion with a low-concentration multidrug mixture could be considered as an alternative modality for intractable pain relief in older adults or in malignancies.

  2. Noninvasive deadbeat control of an implantable rotary blood pump: a simulation study.

    Science.gov (United States)

    Lim, E; Alomari, A H; Savkin, A V; Lovell, N H

    2009-01-01

    A deadbeat controller has been proposed for the control of pulsatile pump flow in an implantable rotary blood pump (IRBP). A lumped parameter model of the cardiovascular system, in combination with the stable dynamical models of pulsatile flow and differential pressure (head) estimation for the IRBP was used to evaluate the controller. Pump speed and current were used as the only measured variables of the control system. The control algorithm was tested using both constant and sinusoidal reference pump flow input, under healthy and heart failure conditions. Results showed that the controller is able to track the reference input with minimal error in the presence of model uncertainty.

  3. Impact of intravenous lidocaine infusion on postoperative analgesia and recovery from surgery: a systematic review of randomized controlled trials.

    Science.gov (United States)

    McCarthy, Grace C; Megalla, Sohair A; Habib, Ashraf S

    2010-06-18

    Postoperative pain continues to be inadequately managed. While opioids remain the mainstay for postoperative analgesia, their use can be associated with adverse effects, including ileus, which can prolong hospital stay. A number of studies have investigated the use of perioperative intravenous lidocaine infusion for improving postoperative analgesia and enhancing recovery of bowel function. This systematic review was performed to determine the overall efficacy of intravenous lidocaine infusion on postoperative analgesia and recovery from surgery in patients undergoing various surgical procedures. We searched the databases of MEDLINE, CINAHL and the Cochrane Library from 1966 to December 2009. We searched for randomized controlled comparisons of lidocaine infusion with placebo in the surgical setting and reporting on postoperative analgesia and other aspects of patient recovery from surgery. The quality of all included studies was assessed using the Modified Oxford Scale. Information on postoperative pain intensity and analgesic requirements was extracted from the trials and compared qualitatively. Other relevant data such as return of bowel function, length of hospital stay, intraoperative anaesthetic requirement and adverse effects were also compared. Sixteen trials were included. A total of 395 patients received intravenous lidocaine with 369 controls. In open and laparoscopic abdominal surgery, as well as in ambulatory surgery patients, intravenous perioperative infusion of lidocaine resulted in significant reductions in postoperative pain intensity and opioid consumption. Pain scores were reduced at rest and with cough or movement for up to 48 hours postoperatively. Opioid consumption was reduced by up to 85% in lidocaine-treated patients when compared with controls. Infusion of lidocaine also resulted in earlier return of bowel function, allowing for earlier rehabilitation and shorter duration of hospital stay. First flatus occurred up to 23 hours earlier

  4. Population pharmacokinetics of rocuronium delivered by target-controlled infusion in adult patients

    Institute of Scientific and Technical Information of China (English)

    YANG Lu; WANG Hui-ling; ZHANG Li-ping; BI Shan-shan; LU Wei; YANG Ba-xian; GUO Xiang-yang

    2010-01-01

    Background Target-controlled infusion (TCI) has been recently developed and successfully implemented in clinical practice. The current study was to estimate the population pharmacokinetics of rocuronium TCI in adult patients using nonlinear mixed-effects model (NONMEM), and to investigate the influence of relevant factors in adult patients.Methods Fourteen ASA Ⅰ-Ⅱ patients undergoing elective laparoscopy operation with general anesthesia were included.After induction, all patients received rocuronium by TCI system. The beginning target plasma concentration (Cpt) was 2.0 μg/ml, then increased Cpt according to the neuromuscular transmission monitoring. The endpoint of Cpt was determined when the T1 scale was blocked by 90%-95%. TCI rocuronium was stopped 30 minutes before the end of the operation.Arterial blood was drawn before anesthesia at 0, 2, 4, 6, 8, 10, 15, 20, 30, 45, 60, 120, 180, 240 and 360 minutes after the infusion of rocuronium was stopped for the analysis of plasma concentrations of rocuronium by liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS). The population pharmacokinetics analysis was performed using NONMEM program.Results The pharmacokinetics of TCI rocuronium in adult patients was best described by a three-comparment model.Pharmacokintic parameters were clearance (CL)1=0.205 L/min, CL2=0.324 L/min, CL3=0.0292 L/min, volumes of distribution (V)1=4.00 L, V2=2.28 L, V3=4.26 L, Vdss=10.54 L. Both age and weight as covariates affected the pharmacokinetic parameters. V1 and CL1 were negatively correlated with patient age. CL1 was positively correlated with weight.Conclusions No pharmacokinetic change was noted when rocuronium was administered via TCI. Both age and weight as covariates affected the pharmacokinetic parameters.

  5. Desflurane reinforces the efficacy of propofol target-controlled infusion in patients undergoing laparoscopic cholecystectomy.

    Science.gov (United States)

    Chen, Po-Nien; Lu, I-Cheng; Chen, Hui-Ming; Cheng, Kuang-I; Tseng, Kuang-Yi; Lee, King-Teh

    2016-01-01

    Whether low-concentration desflurane reinforces propofol-based intravenous anesthesia on maintenance of anesthesia for patients undergoing laparoscopic cholecystectomy is to be determined. The aim of this study was to investigate whether propofol-based anesthesia adding low-concentration desflurane is feasible for laparoscopic cholecystectomy. Fifty-two patients undergoing laparoscopic cholecystectomy were enrolled in the prospective, randomized, clinical trial. Induction of anesthesia was achieved in all patients with fentanyl 2 μg/kg, lidocaine 1 mg/kg, propofol 2 mg/kg, and rocuronium 0.8 mg/kg to facilitate tracheal intubation and to initiate propofol target-controlled infusion (TCI) to effect site concentration (Ce: 4 μg/mL with infusion rate 400 mL/h). The patients were then allocated into either propofol TCI based (group P) or propofol TCI adding low-concentration desflurane (group PD) for maintenance of anesthesia. The peri-anesthesia hemodynamic responses to stimuli were measured. The perioperative psychomotor test included p-deletion test, minus calculation, orientation, and alert/sedation scales. Group PD showed stable hemodynamic responses at CO2 inflation, initial 15 minutes of operation, and recovery from general anesthesia as compared with group P. There is no significant difference between the groups in operation time and anesthesia time, perioperative psychomotor functional tests, postoperative vomiting, and pain score. Based on our findings, the anesthetic technique combination propofol and desflurane for the maintenance of general anesthesia for laparoscopic cholecystectomy provided more stable hemodynamic responses than propofol alone. The combined regimen is recommended for patients undergoing laparoscopic cholecystectomy.

  6. Antinociceptive effects, metabolism and disposition of ketamine in ponies under target-controlled drug infusion

    Science.gov (United States)

    Knobloch, M.; Portier, C.J.; Levionnois, O.L.; Theurillat, R.; Thormann, W.; Spadavecchia, C.; Mevissen, M.

    2007-01-01

    Ketamine is widely used as an anesthetic in a variety of drug combinations in human and veterinary medicine. Recently, it gained new interest for use in long-term pain therapy administered in sub-anesthetic doses in humans and animals. The purpose of this study was to develop a physiologically based pharmacokinetic (PBPk) model for ketamine in ponies and to investigate the effect of low-dose ketamine infusion on the amplitude and the duration of the nociceptive withdrawal reflex (NWR). A target-controlled infusion (TCI) of ketamine with a target plasma level of 1 μg/ml S-ketamine over 120 min under isoflurane anesthesia was performed in Shetland ponies. A quantitative electromyographic assessment of the NWR was done before, during and after the TCI. Plasma levels of R-/S-ketamine and R-/S-norketamine were determined by enantioselective capillary electrophoresis. These data and two additional data sets from bolus studies were used to build a PBPk model for ketamine in ponies. The peak-to-peak amplitude and the duration of the NWR decreased significantly during TCI and returned slowly toward baseline values after the end of TCI. The PBPk model provides reliable prediction of plasma and tissue levels of R- and S-ketamine and R- and S-norketamine. Furthermore, biotransformation of ketamine takes place in the liver and in the lung via first-pass metabolism. Plasma concentrations of S-norketamine were higher compared to R-norketamine during TCI at all time points. Analysis of the data suggested identical biotransformation rates from the parent compounds to the principle metabolites (R- and S-norketamine) but different downstream metabolism to further metabolites. The PBPk model can provide predictions of R- and S-ketamine and norketamine concentrations in other clinical settings (e.g. horses). PMID:16919695

  7. Desflurane reinforces the efficacy of propofol target-controlled infusion in patients undergoing laparoscopic cholecystectomy

    Directory of Open Access Journals (Sweden)

    Po-Nien Chen

    2016-01-01

    Full Text Available Whether low-concentration desflurane reinforces propofol-based intravenous anesthesia on maintenance of anesthesia for patients undergoing laparoscopic cholecystectomy is to be determined. The aim of this study was to investigate whether propofol-based anesthesia adding low-concentration desflurane is feasible for laparoscopic cholecystectomy. Fifty-two patients undergoing laparoscopic cholecystectomy were enrolled in the prospective, randomized, clinical trial. Induction of anesthesia was achieved in all patients with fentanyl 2 μg/kg, lidocaine 1 mg/kg, propofol 2 mg/kg, and rocuronium 0.8 mg/kg to facilitate tracheal intubation and to initiate propofol target-controlled infusion (TCI to effect site concentration (Ce: 4 μg/mL with infusion rate 400 mL/h. The patients were then allocated into either propofol TCI based (group P or propofol TCI adding low-concentration desflurane (group PD for maintenance of anesthesia. The peri-anesthesia hemodynamic responses to stimuli were measured. The perioperative psychomotor test included p-deletion test, minus calculation, orientation, and alert/sedation scales. Group PD showed stable hemodynamic responses at CO2 inflation, initial 15 minutes of operation, and recovery from general anesthesia as compared with group P. There is no significant difference between the groups in operation time and anesthesia time, perioperative psychomotor functional tests, postoperative vomiting, and pain score. Based on our findings, the anesthetic technique combination propofol and desflurane for the maintenance of general anesthesia for laparoscopic cholecystectomy provided more stable hemodynamic responses than propofol alone. The combined regimen is recommended for patients undergoing laparoscopic cholecystectomy.

  8. Clinical observation of continuously subcutaneous-pumped octreotide infusion in palliative treatment of malignant bowel obstruction%奥曲肽持续皮下泵入治疗恶性肠梗阻的临床观察

    Institute of Scientific and Technical Information of China (English)

    Dongfeng Yin; Yin Zhu; Yuqing Xing; Hong Gao; Yuzhen Pan; Lin Pan; Guangyi Tang; Xiangrong Xing; Lijiang Zhou

    2011-01-01

    objective: The aim of the study was to observe the effectiveness of continuously subcutaneous-pumped octreotide infusion in palliative treatment of malignant bowel obstruction (MBO). Methods: Clinical data were retrospectively analyzed in 26 carcinoma patients complicated with MBO, in the Affiliated Hospital of Liaoning University of Traditional Chinese Medicine, China, from March 2007 to April 2009. All 26 carcinoma patients with MBO were divided into two groups: the controlling group (CG, routine therapy, 15 patients) and the octreotide group (OG, 11 patients). The octreotide group received routine therapy combined with octreotide (0.3 mg/d) by 24 hours continuously subcutaneous octreotide infusion. The changes of curative effectiveness related to symptoms, the times of recovering exsufflation and defecation, the average drain of gastrointestinal drainage tube, the duration of gastrointestinal drainage tube and the rate of extubation, were observed and compared between the two groups. Results: After treatment, remarkable changing rates of MBO related symptoms were 81.8%(9/11)in OG, and 46.7%(7/15) in CG(P<0.05). The 78% of SG and 30% of CG recovered the exsufflation and defecation, and the mean times they needed were 3.2 d and 5.8 d, respectively (P < 0.05). The durations of gastrointestinal drainage tube of OG and CG were (5 ± 1.2) d and (10 ± 2.3) d, respectively, and the rates of extubation were 54.5% and 20%, respectively. The improvement rate in the octreotide group was better than that in the controlling group and the difference was significant (72.7%and 26.7%, P < 0.05). Conclusion: The administration of octreotide in combination with routine treatment can be very effective in the treatment of MBO. It can relieve the symptoms of MBO effectively and improve the quality of life of the end-stage patients. It has provided one kind of new treating thought and method for treatment of malignant bowel obstruction.

  9. Designing an Electro-Hydraulic Control Module for an Open-Circuit Variable Displacement Pump

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen; Andersen, Torben Ole; Hansen, Michael Rygaard

    2005-01-01

    , in the form of an electric control signal, under varying working conditions, when having access to engine speed and actual pump pressure. The paper presents a model of both the pump and the control module, along with design considerations on which linear controllers are developed for a worst point...

  10. Infusion Extractor

    Science.gov (United States)

    Chang-Diaz, Franklin R.

    1988-01-01

    Apparatus and method of removing desirable constituents from an infusible material by infusion extraction, where a piston operating in a first chamber draws a solvent into the first chamber where it may be heated, and then moves the heated solvent into a second chamber containing the infusible material, and where infusion extraction takes place. The piston then moves the solvent containing the extract through a filter into the first chamber, leaving the extraction residue in the second chamber.

  11. Ripple reduction control of the undulation pump total artificial heart.

    Science.gov (United States)

    Saito, Itsuro; Chinzei, Tsuneo; Mochizuki, Shuichi; Abe, Yusuke; Isoyama, Takashi; Iwasaki, Kiyotaka; Suzuki, Takafumi; Karita, Tatsuro; Ono, Toshiya; Kouno, Akimasa; Ishimaru, Mitsuhiko; Baba, Atsushi; Ozeki, Toshinaga; Tohyama, Takahiro; Kobayashi Si, Shin-ichi; Imachi, Kou

    2002-01-01

    An undulation pump total artificial heart (UPTAH) in which the revolutions of the motor are converted to undulation motion of a disk has been developed. In an experiment, a goat using the UPTAH survived for 54 days. However, a large ripple was observed in the device's output pressure and flow waveform. In calculating the spectrum of the ripple, we found that the ripple mainly comprised 2 frequency sine waves: 1 having the same frequency as and 1 having double the frequency of the motor revolutions. To reduce the ripple, 2 sine waves, 1 having the same frequency as and 1 having double the frequency of the motor revolutions, were provided to the motor current to modulate the pulse width of the pulse width modulation controlling the motor revolutions. This ripple control method reduced the pressure ripple by 90% in a mock circulation and by 70% in animal experiments. These results revealed that the ripple generated in the UPTAH could be controlled through the use of motor control software.

  12. In silico evaluation of a control system and algorithm for automated insulin infusion in the ICU setting

    Directory of Open Access Journals (Sweden)

    Olmos Pablo R

    2010-07-01

    Full Text Available Abstract Background It is known that tight control of glucose in the Intensive Care Unit reduces morbidity and mortality not only in diabetic patients but also in those non-diabetics who become transiently hyperglycemic. Taking advantage of a recently marketed subcutaneous glucose sensor we designed an Automatic Insulin Infusion System (AIIS for inpatient treatment, and tested its stability under simulated clinical conditions. Methods The system included: reference glucose, glucose sensor, insulin and glucose infusion controllers and emergency infusion logic. We carried out computer simulations using Matlab/Simulink®, in both common and worst-case conditions. Results The system was capable of controlling glucose levels without entering in a phase of catastrophic instability, even under severe simulated challenges. Care was taken to include in all simulations the 5-10 minute delay of the subcutaneous glucose signal when compared to the real-time serum glucose signal, a well-known characteristic of all subcutaneous glucose sensors. Conclusions When tested in-Silico, a commercially available subcutaneous glucose sensor allowed the stable functioning of a proportional-derivative Automatic Insulin Infusion System, which was able to maintain glucose within acceptable limits when using a well-established glucose response model simulating a patient. Testing of the system in vivo using animal models is now warranted.

  13. The SWITCH study (sensing with insulin pump therapy to control HbA(1c))

    DEFF Research Database (Denmark)

    Conget, Ignacio; Battelino, Tadej; Giménez, Marga

    2011-01-01

    studies investigating the effect of real-time continuous glucose monitoring (CGM) combined with pump therapy on glycemic outcomes in type 1 diabetes are increasing. Pump therapy is well established as a "gold standard" for insulin delivery, offering improvements over multiple daily insulin inject......]) study is a multicenter, randomized, controlled, crossover study to evaluate if adding CGM to experienced pump patients with suboptimal metabolic control will provide additional insight enabling clinical and therapeutic benefit....

  14. Variable flow controls of closed system pumps for energy savings in maritime power systems

    DEFF Research Database (Denmark)

    Su, Chun-Lien; Liao, Chi-Hsiang; Chou, Tso-Chu

    2016-01-01

    Pumps are extensively used in maritime industries as marine vessels utilize a wide range of pumps and pumping techniques to transfer and distribute all types of air and fluids. The electrical energy consumed by the various motors accounts for about 70% of a vessel’s total power consumption...... pumps on marine vessels. The existing problem of traditional control methods for closed system pumps is analyzed and a mathematical model for variable flow controls with the appropriate control settings is derived. The performance of the proposed method is demonstrated and verified through experimental...... and field tests of a practical auxiliary boiler feed water management system on a commercial vessel. It is proved that the proposed method can maintain constant water pressure for closed system pumps and provide an efficient way to measure energy savings and maintenance benefits. The results serve...

  15. A randomized, controlled trial comparing local infiltration analgesia with epidural infusion for total knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Karen Vestergaard; Bak, Marie; Christensen, Birgitte Viebæk;

    2010-01-01

    There have been few studies describing wound infiltration with additional intraarticular administration of multimodal analgesia for total knee arthroplasty (TKA). In this study, we assessed the efficacy of wound infiltration combined with intraarticular regional analgesia with epidural infusion...

  16. Modelling and active control of the Vacuum Infusion Process for composites manufacture

    OpenAIRE

    Modi, Dhiren

    2008-01-01

    Vacuum infusion technology, even though first reported more than 50 years ago, was not popular for mainstream fibre reinforced polymer composites manufacturing until recently. Its present-day popularity is due to the increasing emphasis on the manufacturing cost as well as environmental and health concerns. As a result, novel processes such as Vacuum Infusion (VI) and Seemans' Composite Resin Injection Moulding Process (SCRIMPTM), employing the same basic technology, have been developed. As l...

  17. Development and diversity and defense-in-depth application of ABWR feedwater pump and controller model

    Energy Technology Data Exchange (ETDEWEB)

    Huang, H.-W. [Institute of Nuclear Energy Research, No. 1000, Wenhua Road, Chiaan Village, Longtan Township, Taoyuan County, 32546, Taiwan (China)], E-mail: hwhwang@iner.gov.tw; Shih Chunkuan; Hung, H.-C. [Institute of Nuclear Engineering and Science, National Tsing-Hua University, 101, Section 2 Kuang Fu Road, Hsinchu, Taiwan (China); Chen, M.-H. [Institute of Nuclear Energy Research, No. 1000, Wenhua Road, Chiaan Village, Longtan Township, Taoyuan County, 32546, Taiwan (China); Institute of Nuclear Engineering and Science, National Tsing-Hua University, 101, Section 2 Kuang Fu Road, Hsinchu, Taiwan (China)

    2009-06-15

    This work developed an advanced boiling water reactor (ABWR) feedwater pump and controller model, which was incorporated into Personal Computer Transient Analyzer (PCTran)-ABWR, a nuclear power plant simulation code. The feedwater pump model includes three turbine-driven feedwater pumps and one motor-driven feedwater pump. The feedwater controller includes a one-element/three-element water level controller and a specific feedwater speed controller for each feedwater pump. The performance tests, including step change of dome pressure, feedwater pumps transfer, inadvertent closure of all turbine control valves, and one feedwater pump trip at 100% power, demonstrate the feasibility of dynamic response of stand-alone model and incorporated model. Furthermore, a diversity and defense-in-depth analysis is performed to demonstrate the feasibility for motor-driven feedwater pump as an emergency core cooling system (ECCS) automatic diverse back-up. In Lungmen nuclear power plant (NPP), a diverse manual initiation means for the high pressure core flooder (HPCF) loop C is designed as the back-up of digitalized engineered safety features actuation system (ESFAS). If the motor-driven feedwater pump (MDFWP) can be an automatic digital diverse back-up for ESFAS, Lungmen NPP would be more robust to defend against software common-cause failure (CCF)

  18. Direct infusion mass spectrometry metabolomics dataset: a benchmark for data processing and quality control.

    Science.gov (United States)

    Kirwan, Jennifer A; Weber, Ralf J M; Broadhurst, David I; Viant, Mark R

    2014-01-01

    Direct-infusion mass spectrometry (DIMS) metabolomics is an important approach for characterising molecular responses of organisms to disease, drugs and the environment. Increasingly large-scale metabolomics studies are being conducted, necessitating improvements in both bioanalytical and computational workflows to maintain data quality. This dataset represents a systematic evaluation of the reproducibility of a multi-batch DIMS metabolomics study of cardiac tissue extracts. It comprises of twenty biological samples (cow vs. sheep) that were analysed repeatedly, in 8 batches across 7 days, together with a concurrent set of quality control (QC) samples. Data are presented from each step of the workflow and are available in MetaboLights. The strength of the dataset is that intra- and inter-batch variation can be corrected using QC spectra and the quality of this correction assessed independently using the repeatedly-measured biological samples. Originally designed to test the efficacy of a batch-correction algorithm, it will enable others to evaluate novel data processing algorithms. Furthermore, this dataset serves as a benchmark for DIMS metabolomics, derived using best-practice workflows and rigorous quality assessment.

  19. Diet liberalization and metabolic control in type I diabetic outpatients treated by continuous subcutaneous insulin infusion.

    Science.gov (United States)

    Chantelau, E; Sonnenberg, G E; Stanitzek-Schmidt, I; Best, F; Altenähr, H; Berger, M

    1982-01-01

    In 10 type I diabetic outpatients treated by continuous subcutaneous insulin infusion (CSII), dietary habits and metabolic control were investigated. Under conditions of a conventional diabetes diet (including 5-6 meals per day and a strictly planned meal intake) as well as under a "less restricted diabetes diet" (e.g., free choice of number, timing, and amount of carbohydrate intake) near normoglycemia could be achieved. Mean daily blood glucose levels did not change significantly when the patients' nutrition was alternated between both diets. During the "less restricted diabetes diet," the patients opted for a rather high fat intake (51 +/- 5% fat, 34 +/- 5% carbohydrate, and 15 +/- 2% protein). Despite this unintended dietary behavior, serum lipids and body weight remained normal after an observation period of 4-6 mo. It is concluded that during permanent near normoglycemia achieved by CSII a partial liberalization of the diabetes diet does not introduce any short-term or long-term metabolic risk factors for cardiovascular diseases.

  20. Evidence for coordinate genetic control of Na,K pump density in erythrocytes and lymphocytes

    Energy Technology Data Exchange (ETDEWEB)

    DeLuise, M.; Flier, J.S.

    1985-08-01

    The erythrocyte is widely used as a model cell for studies of the Na,K pump in health and disease. However, little is known about the factors that control the number of Na,K pumps expressed on the erythrocytes of a given individual, nor about the extent to which erythrocytes can be used to validly assess the pump density on other cell types. In this report, the authors have compared the interindividual variance of Na,K pump density in erythrocytes of unrelated individuals to that seen with identical twins. Unlike unrelated individuals, in whom pump parameters, i.e., ouabain binding sites, /sup 86/Rb uptake, and cell Na concentration vary widely, identical twin pairs showed no significant intrapair variation for these values. Thus, a role for genetic factors is suggested. In addition, the authors established and validated a method for determining Na,K pump density and pump-mediated /sup 86/Rb uptake in human peripheral lymphocytes. Using this method, they show that whereas Na,K pump density differs markedly between erythrocytes (mean of 285 sites per cell) and lymphocytes (mean 40,600 sites per cell), there is a strong and highly significant correlation (r = 0.79, P less than 0.001) between the pump density in these cell types in any given individual. Taken together, these studies suggest that genetic factors are important determinants of Na,K pump expression, and that pump density appears to be coordinately regulated in two cell types in healthy individuals.

  1. Control of Electric Drives in the Best Efficiency Region of Pumping System

    Directory of Open Access Journals (Sweden)

    Bakman Ilja

    2014-10-01

    Full Text Available The paper concentrates on improving the efficiency of the pumping system in which pumps are run by variable speed drives. The method is applicable to system consisting of several centrifugal pumps. Problems arising from running the pumps outside the optimal efficiency region are discussed. Common principles of operation and control of typical boosting pumping station are represented. Methods of regulation of productivity of the system are described. The proposed method is based on prediction of future efficiency of pumps before making adjustments of pumping system productivity. The proposed method is basing on tracking the working point of pump on efficiency graph. Monitoring the location of working point vs. efficiency graph enables to evaluate its current and future distances from the best efficiency point of the pump. Knowing the current number of running pumps it is possible to predict the location of working point after adjustment of productivity of the system. Ability to predict the increase or decrease of efficiency enables to enhance the adjustment of productivity of the system. Methods of graphical analysis of working state of the pumping system are representing topic for future research.

  2. The haemodynamic effects of the perioperative terlipressin infusion in living donor liver transplantation: A randomised controlled study

    OpenAIRE

    Nagwa Ibrahim; Ashraf Hasanin; Sabry Abd Allah; Eman Sayed; Mohamed Afifi; Khaled Yassen; Wesam Saber; Magdy Khalil

    2015-01-01

    Background and Aims: Liver disease is usually accompanied with a decline in systemic vascular resistance (SVR). We decided to assess effects of the peri-operative terlipressin infusion on liver donor liver transplantation recipients with respect to haemodynamics and renal parameters. Methods: After Ethical Committee approval for this prospective randomised controlled study, 50 recipients were enrolled and allotted to control (n = 25) or terlipressin group (n = 25) with simple randomisation me...

  3. Controlling the Gilbert damping using spin pumping and magnetic impurities

    Science.gov (United States)

    Verhagen, Tim; Tinkey, Holly; van Ruitenbeek, Jan; Aarts, Jan

    2013-03-01

    The ability to control the magnetic damping parameter of thin magnetic films is an important issue when designing for example giant magnetoresistance (GMR) devices. A well-known way to influence the damping of the ferromagnetic (F) layer is by using the spin pumping effect in which a spin current is emitted into an adjacent normal (N) layer by bringing the F-layer into ferromagnetic resonance (FMR). As N layer, we used the well studied strongly spin sinking material Pt and the bad spin sink Cu, but also a Cu layer with Co impurities. We find that by adding a small amount of Co impurities, the Cu layer becomes as effective in damping as a Pt layer. In the latter case, the damping is caused by the strong spin orbit coupling. Using magnetic impurities, we rather make use of the inelastic spin scattering. This opens up new ways to control the damping of a ferromagnetic thin layer, for example in current-in-plane (CIP) GMR sensors, where the extra damping can suppress the spin transfer torque which becomes dominant with the further decrease of the size of the sensor.

  4. Design Document for Control Dewar and Vacuum Pump Platforms

    Energy Technology Data Exchange (ETDEWEB)

    Rucinksi, R.; /Fermilab

    1997-08-27

    This engineering note documents the design of the control dewar and vacuum pump platform that is to be installed on the D-Zero detector. It's purpose is twofold. Firstly it is a summary and repository of the final design calculations of the structure. Secondly, it documents that design follows the American Institute of Steel Construction (AISC) manual and applicable OSHA requirements with respect to walking working surfaces. The information contained in the main body of this note is supported by raw calculations included as the appendix. The platform is a truss type frame strucrure constructed primarily of rectangular steel tubing. The upper platform is for support of the control dewar (cryogenic/electrical interface for the solenoid), visible light photon counter (VLPC) cryogenic bayonet can, and infrequently, personnel during the connection and disconnection of the detector to building services. Figure 1 shows a layout of the structure as mounted on the detector and with the installed equipment. The connection of the platform to the detector is not conventional. Two main booms cantilever the structure to a location outside of the detector. The mounting location and support booms allow for the uninhibited motion of the detector components.

  5. Experimental Investigation and Passive Flow Control of a Cavitating Centrifugal Pump

    Directory of Open Access Journals (Sweden)

    Spyridon D. Kyparissis

    2012-01-01

    Full Text Available Passive flow control techniques are used to improve the flow field and efficiency of centrifugal pumps and turbomachines, in general. An important phenomenon that mechanical engineers have to take into account is cavitation. It leads to the decrease of the pump performance and total head. In the present experimental study, a centrifugal pump is investigated in cavitating conditions. A passive flow control is realized using three different blade leading edge angles in order to reduce the cavitation development and enhance the pump performance. The experiments are carried out in a pump test rig specially designed and constructed, along with the impellers. The head drop and total efficiency curves are presented in order to examine the effect of the blade leading edge angle on the cavitation and pump performance. Finally, the vapour distribution along with the blades is illustrated for the tested blade leading edge angles.

  6. A randomised controlled trial of oxytocin 5IU and placebo infusion versus oxytocin 5IU and 30IU infusion for the control of blood loss at elective caesarean section--pilot study. ISRCTN 40302163.

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2012-02-01

    OBJECTIVE: To compare the blood loss at elective lower segment caesarean section with administration of oxytocin 5IU bolus versus oxytocin 5IU bolus and oxytocin 30IU infusion and to establish whether a large multi-centre trial is feasible. STUDY DESIGN: Women booked for an elective caesarean section were recruited to a pilot randomised controlled trial and randomised to either oxytocin 5IU bolus and placebo infusion or oxytocin 5IU bolus and oxytocin 30IU infusion. We wished to establish whether the study design was feasible and acceptable and to establish sample size estimates for a definitive multi-centre trial. The outcome measures were total estimated blood loss at caesarean section and in the immediate postpartum period and the need for an additional uterotonic agent. RESULTS: A total of 115 women were randomised and 110 were suitable for analysis (5 protocol violations). Despite strict exclusion criteria 84% of the target population were considered eligible for study participation and of those approached only 15% declined to participate and 11% delivered prior to the planned date. The total mean estimated blood loss was lower in the oxytocin infusion arm compared to placebo (567 ml versus 624 ml) and fewer women had a major haemorrhage (>1000 ml, 14% versus 17%) or required an additional uterotonic agent (5% versus 11%). A sample size of 1500 in each arm would be required to demonstrate a 3% absolute reduction in major haemorrhage (from baseline 10%) with >80% power. CONCLUSION: An additional oxytocin infusion at elective caesarean section may reduce blood loss and warrants evaluation in a large multi-centre trial.

  7. Numerical and clinical precision of continuous glucose monitoring in Colombian patients treated with insulin infusion pump with automated suspension in hypoglycemia.

    Science.gov (United States)

    Gómez, Ana M; Marín Sánchez, Alejandro; Muñoz, Oscar M; Colón Peña, Christian Alejandro

    2015-12-01

    Insulin pump therapy associated with continuous glucose monitoring has shown a positive clinical impact on diabetes control and reduction of hypoglycemia episodes. There are descriptions of the performance of this device in other populations, but its precision and accuracy in Colombia and Latin America are unknown, especially in the routine outpatient setting. Data from 33 type 1 and type 2 diabetes patients with sensor-augmented pump therapy with threshold suspend automation, MiniMed Paradigm® Veo™ (Medtronic, Northridge, California), managed at Hospital Universitario San Ignacio (Bogotá, Colombia) and receiving outpatient treatment, were analyzed. Simultaneous data from continuous glucose monitoring and capillary blood glucose were compared, and their precision and accuracy were calculating with different methods, including Clarke error grid. Analyses included 2,262 continuous glucose monitoring -reference paired glucose values. A mean absolute relative difference of 20.1% was found for all measurements, with a value higher than 23% for glucose levels ≤75mg/dL. Global compliance with the ISO criteria was 64.9%. It was higher for values >75mg/dl (68.3%, 1,308 of 1,916 readings), than for those ≤ 75mg/dl (49.4%, 171 of 346 readings). Clinical accuracy, as assessed by the Clarke error grid, showed that 91.77% of data were within the A and B zones (75.6% in hypoglycemia). A good numerical accuracy was found for continuous glucose monitoring in normo and hyperglycemia situations, with low precision in hypoglycemia. The clinical accuracy of the device was adequate, with no significant safety concerns for patients. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  8. A prospective, randomized, blinded-endpoint, controlled study - continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia

    Directory of Open Access Journals (Sweden)

    Joana Nunes

    Full Text Available Abstract Background: There is evidence that administration of a programmed intermittent epidural bolus (PIEB compared to continuous epidural infusion (CEI leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. Methods: In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10 mL with Ropivacaine 0.16% plus Sufentanil 10 µg, parturient were randomly assigned to one of three regimens: A - Ropivacaine 0.15% plus Sufentanil 0.2 µg/mL solution as continuous epidural infusion (5 mL/h, beginning immediately after the initial bolus; B - Ropivacaine 0.1% plus Sufentanil 0.2 µg/mL as programmed intermittent epidural bolus and C - Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10 mL/h starting 60 min after the initial bolus. Rescue boluses of 5 mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. Results: We analyzed 130 pregnants (A = 60; B = 33; C = 37. The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p = 0.83. We found a higher caesarean delivery rate in group A (56.7%; p = 0.02. No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Conclusions: Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes.

  9. A randomised controlled trial of two infusion rates to decrease reactions to antivenom.

    Directory of Open Access Journals (Sweden)

    Geoffrey K Isbister

    Full Text Available BACKGROUND: Snake envenoming is a major clinical problem in Sri Lanka, with an estimated 40,000 bites annually. Antivenom is only available from India and there is a high rate of systemic hypersensitivity reactions. This study aimed to investigate whether the rate of infusion of antivenom reduced the frequency of severe systemic hypersensitivity reactions. METHODS AND FINDINGS: This was a randomized comparison trial of two infusion rates of antivenom for treatment of non-pregnant adult patients (>14 y with snake envenoming in Sri Lanka. Snake identification was by patient or hospital examination of dead snakes when available and confirmed by enzyme-immunoassay for Russell's viper envenoming. Patients were blindly allocated in a 11 randomisation schedule to receive antivenom either as a 20 minute infusion (rapid or a two hour infusion (slow. The primary outcome was the proportion with severe systemic hypersensitivity reactions (grade 3 by Brown grading system within 4 hours of commencement of antivenom. Secondary outcomes included the proportion with mild/moderate hypersensitivity reactions and repeat antivenom doses. Of 1004 patients with suspected snakebites, 247 patients received antivenom. 49 patients were excluded or not recruited leaving 104 patients allocated to the rapid antivenom infusion and 94 to the slow antivenom infusion. The median actual duration of antivenom infusion in the rapid group was 20 min (Interquartile range[IQR]:20-25 min versus 120 min (IQR:75-120 min in the slow group. There was no difference in severe systemic hypersensitivity reactions between those given rapid and slow infusions (32% vs. 35%; difference 3%; 95%CI:-10% to +17%;p = 0.65. The frequency of mild/moderate reactions was also similar. Similar numbers of patients in each arm received further doses of antivenom (30/104 vs. 23/94. CONCLUSIONS: A slower infusion rate would not reduce the rate of severe systemic hypersensitivity reactions from current high

  10. Erythromycin infusion prior to endoscopy for acute nonvariceal upper gastrointestinal bleeding: a pilot randomized controlled trial.

    Science.gov (United States)

    Na, Hee Kyong; Jung, Hwoon-Yong; Seo, Dong Woo; Lim, Hyun; Ahn, Ji Yong; Lee, Jeong Hoon; Kim, Do Hoon; Choi, Kee Don; Song, Ho June; Lee, Gin Hyug; Kim, Jin-Ho

    2017-03-28

    The aim of this study was to compare the effects of erythromycin infusion and gastric lavage in order to improve the quality of visualization during emergency upper endoscopy. We performed a prospective randomized pilot study. Patients presented with hematemesis or melena within 12 hours and were randomly assigned to the erythromycin group (intravenous infusion of erythromycin), gastric lavage group (nasogastric tube placement with gastric lavage), or erythromycin + gastric lavage group (both erythromycin infusion and gastric lavage). The primary outcome was satisfactory visualization. Secondary outcomes included identification of a bleeding source, the success rate of hemostasis, duration of endoscopy, complications related to erythromycin infusion or gastric lavage, number of transfused blood units, rebleeding rate, and bleeding-related mortality. A total of 43 patients were randomly assigned: 14 patients in the erythromycin group; 15 patients in the gastric lavage group; and 14 patients in the erythromycin + gastric lavage group. Overall satisfactory visualization was achieved in 81% of patients: 92.8% in the erythromycin group; 60.0% in the gastric lavage group; and 92.9% in the erythromycin + gastric lavage group, respectively (p = 0.055). The identification of a bleeding source was possible in all cases. The success rate of hemostasis, duration of endoscopy, and number of transfused blood units did not significantly differ between groups. There were no complications. Rebleeding occurred in three patients (7.0%). Bleeding-related mortality was not reported. Intravenous erythromycin infusion prior to emergency endoscopy for acute nonvariceal upper gastrointestinal bleeding seems to provide satisfactory endoscopic visualization.

  11. Elimination of Oscillations in a Central Heating System using Pump Control

    DEFF Research Database (Denmark)

    Andersen, Palle; Pedersen, Tom Søndergaard; Stoustrup, Jakob;

    2000-01-01

    In central heating systems with thermostatic valve temperature control it is a well known fact that room temperature oscillations may occur when the heat demand becomes low due to the non-linear behavior of the control loop. This is not only discomforting but it also increases the energy cost...... of heating the room. Using the pump speed as an active part in control is it shown that the room temperature may be stabilized in a wider interval of heat demand. The idea is to control the pump speed in a way that keeps the thermostatic valve within a suitable operating area using an estimate of the valve...... position. The position is estimated from the pump terminals, using the pump flow and the pump differential pressure. The concept is tested on a small central heating test bench. The results show that it is possible to stabilize the room temperature even at part load conditions...

  12. Clinical Efficacy of Two Different Methods to Initiate Sensor-Augmented Insulin Pumps: A Randomized Controlled Trial

    Science.gov (United States)

    Gómez, Francisco Javier; Gálvez Moreno, Maria Ángeles; Castaño, Justo P.

    2016-01-01

    Aim. To analyze clinical effect of a novel approach to initiate sensor-augmented insulin pumps in type 1 diabetes mellitus (T1DM) patients through early real-time continuous glucose monitoring (RT-CGM) initiation. Methods. A 26-week pilot study with T1DM subjects randomized (1 : 1) to start RT-CGM three weeks before continuous subcutaneous insulin infusion (CGM pre-CSII) or adding RT-CGM three weeks after continuous subcutaneous insulin infusion (CGM post-CSII). Results. Twenty-two patients were enrolled with a mean age of 36.6 yr. (range 19–59 yr.) and T1DM duration of 16.8 ± 10.6 yr. Higher adherence in CGM pre-CSII patients was confirmed at study end (84.6 ± 11.1% versus 64.0 ± 25.4%; P = 0.01). The two intervention groups had similar HbA1c reduction at study end of −0.6% (P = 0.9). Hypoglycemic event frequency reduction was observed from baseline to study end only in CGM pre-CSII group (mean difference in change, −6.3%; 95% confidence interval, −12.0 to −0.5; P = 0.04). Moreover, no severe hypoglycemia was detected among CGM pre-CSII subjects during the study follow-up (0.0 ± 0.0 events versus 0.63 ± 1.0 events; P = 0.03). CGM pre-CSII patients showed better satisfaction than CGM post-CSII patients at the end of the study (27.3 ± 9.3 versus 32.9 ± 7.2; P = 0.04). Conclusions. CGM pre-CSII is a novel approach to improve glycemic control and satisfaction in type 1 diabetes sensor-augmented pump treated patients. PMID:28004007

  13. Clinical Efficacy of Two Different Methods to Initiate Sensor-Augmented Insulin Pumps: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Jesus Moreno-Fernandez

    2016-01-01

    Full Text Available Aim. To analyze clinical effect of a novel approach to initiate sensor-augmented insulin pumps in type 1 diabetes mellitus (T1DM patients through early real-time continuous glucose monitoring (RT-CGM initiation. Methods. A 26-week pilot study with T1DM subjects randomized (1 : 1 to start RT-CGM three weeks before continuous subcutaneous insulin infusion (CGM pre-CSII or adding RT-CGM three weeks after continuous subcutaneous insulin infusion (CGM post-CSII. Results. Twenty-two patients were enrolled with a mean age of 36.6 yr. (range 19–59 yr. and T1DM duration of 16.8±10.6 yr. Higher adherence in CGM pre-CSII patients was confirmed at study end (84.6±11.1% versus 64.0±25.4%; P=0.01. The two intervention groups had similar HbA1c reduction at study end of −0.6% (P=0.9. Hypoglycemic event frequency reduction was observed from baseline to study end only in CGM pre-CSII group (mean difference in change, −6.3%; 95% confidence interval, −12.0 to −0.5; P=0.04. Moreover, no severe hypoglycemia was detected among CGM pre-CSII subjects during the study follow-up (0.0±0.0 events versus 0.63±1.0 events; P=0.03. CGM pre-CSII patients showed better satisfaction than CGM post-CSII patients at the end of the study (27.3±9.3 versus 32.9±7.2; P=0.04. Conclusions. CGM pre-CSII is a novel approach to improve glycemic control and satisfaction in type 1 diabetes sensor-augmented pump treated patients.

  14. FORMULATION AND EVALUATION OF BACLOFEN CONTROLLED POROSITY OSMOTIC PUMP TABLETS

    Directory of Open Access Journals (Sweden)

    Indarapu Rajendra Prasad

    2013-06-01

    Full Text Available In the present study, attempts were made to develop and evaluate the controlled porosity osmotic pump (CPOP based drug delivery system of sparingly water soluble drug Baclofen. Formulation variables, such as, levels of solubility enhancer, ratio of drug to osmogents, coat thickness of semi permeable membrane (SPM and level of pore former were found to affect the drug release from the developed formulations. Cellulose acetate was used as the semi permeable membrane. Drug release was directly proportional to the level of the solubility enhancer, osmotic pressure generated by osmotic agent and level of pore former; however, was inversely proportional to the coat thickness of SPM. Drug release from developed formulations was independent of pH and agitation intensities of release media. Burst strength of the exhausted shells decreased with increase in the level of pore former. This system was found to deliver Baclofen at a zero-order rate. The optimized formulations were subjected to stability studies as per ICH guidelines, and formulations were found to be stable after 45days study.

  15. Open Source Patient-Controlled Analgesic Pump Requirements Documentation.

    Science.gov (United States)

    Larson, Brian R; Hatcliff, John; Chalin, Patrice

    2013-01-01

    The dynamic nature of the medical domain is driving a need for continuous innovation and improvement in techniques for developing and assuring medical devices. Unfortunately, research in academia and communication between academics, industrial engineers, and regulatory authorities is hampered by the lack of realistic non-proprietary development artifacts for medical devices. In this paper, we give an overview of a detailed requirements document for a Patient-Controlled Analgesic (PCA) pump developed under the US NSF's Food and Drug Administration (FDA) Scholar-in-Residence (SIR) program. This 60+ page document follows the methodology outlined in the US Federal Aviation Administrations (FAA) Requirements Engineering Management Handbook (REMH) and includes a domain overview, use cases, statements of safety & security requirements, and formal top-level system architectural description. Based on previous experience with release of a requirements document for a cardiac pacemaker that spawned a number of research and pedagogical activities, we believe that the described PCA requirements document can be an important research enabler within the formal methods and software engineering communities.

  16. A sliding mode-based starling-like controller for implantable rotary blood pumps.

    Science.gov (United States)

    Bakouri, Mohsen A; Salamonsen, Robert F; Savkin, Andrey V; AlOmari, Abdul-Hakeem H; Lim, Einly; Lovell, Nigel H

    2014-07-01

    Clinically adequate implementation of physiological control of a rotary left ventricular assist device requires a sophisticated technique such as the recently proposed method based on the Frank-Starling mechanism. In this mechanism, the stroke volume of the heart increases in response to an increase in the volume of blood filling the left ventricle at the end of diastole. To emulate this process, changes in pump speed need to automatically regulate pump flow to ensure that the combined output of the left ventricle and pump match the output of the right ventricle across changing cardiovascular states. In this approach, we exploit the linear relationship between estimated mean pump flow (Q ̅ est) and pump flow pulsatility (PIQp) in a tracking control algorithm based on sliding mode control. The immediate response of the controller was assessed using a lumped parameter model of the cardiovascular system (CVS) and pump from which could be extracted both Q ̅ est and PIQp. Two different perturbations from the resting state in the presence of left ventricular failure were tested. The first was blood loss requiring a reduction in pump flow to match the reduced output from the right ventricle and to avoid the complication of ventricular suction. The second was exercise, requiring an increase in pump flow. The sliding mode controller induced the required changes in Qp within approximately five heart beats in the blood loss simulation and eight heart beats in the exercise simulation without clinically significant transients or steady-state errors.

  17. Patient Controlled Epidural Analgesia during Labour: Effect of Addition of Background Infusion on Quality of Analgesia & Maternal Satisfaction

    Directory of Open Access Journals (Sweden)

    Uma Srivastava

    2009-01-01

    Full Text Available Patient controlled epidural analgesia (PCEA is a well established technique for pain relief during labor. But the inclusion of continuous background infusion to PCEA is controversial. The aim of this study was to assess whether the use of continuous infusion along with PCEA was beneficial for laboring women with regards to quality of analgesia, maternal satisfaction and neonatal outcome in comparison to PCEA alone. Fifty five parturients received epidural bolus of 10ml solution containing 0.125% bupivacaine +2 ìg.ml-1 of fentanyl. For maintenance of analgesia the patients of Group PCEA self administered 8 ml bolus with lockout interval of 20 minutes of above solution on demand with no basal infusion. While the patients of Group PCEA + CI received continuous epidural infusion at the rate of 10 ml.hr-1 along with self administered boluses of 3 ml with lockout interval of 10 minutes of similar epidural solution. Patients of both groups were given rescue boluses by the anaesthetists for distressing pain. Verbal analogue pain scores, incidence of distressing pain, need of supplementary/rescue boluses, dose of bupivacaine consumed, maternal satisfaction and neonatal Apgar scores were recorded. No significant difference was observed between mean VAS pain scores during labor, maternal satisfaction, mode of delivery or neonatal Apgar scores. But more patients (n=8 required rescue boluses in PCEA group for distressing pain. The total volume consumed of bupivacaine and opioid was slightly more in PCEA + CI group. In both the techniques the highest sensory level, degree of motor block were comparable& prolongation of labor was not seen. It was concluded that both the techniques provided equivalent labor analgesia, maternal satisfaction and neonatal Apgar scores. PCEA along with continuous infusion at the rate of 10 ml/ hr resulted in lesser incidence of distressing pain and need for rescue analgesic. Although this group consumed higher dose of bupivacaine

  18. The haemodynamic effects of the perioperative terlipressin infusion in living donor liver transplantation: A randomised controlled study

    Directory of Open Access Journals (Sweden)

    Nagwa Ibrahim

    2015-01-01

    Full Text Available Background and Aims: Liver disease is usually accompanied with a decline in systemic vascular resistance (SVR. We decided to assess effects of the peri-operative terlipressin infusion on liver donor liver transplantation recipients with respect to haemodynamics and renal parameters. Methods: After Ethical Committee approval for this prospective randomised controlled study, 50 recipients were enrolled and allotted to control (n = 25 or terlipressin group (n = 25 with simple randomisation method. Terlipressin was infused at 1.0 μg/kg/h and later titrated 1.0-4.0 μg/kg/h to maintain mean arterial pressure (MAP >65 mmHg and SVR index 0.05 and was sustained post-operatively. Conclusion: Terlipressin improved SVR and MAP with less need for catecholamines particularly post-reperfusion. Terlipressin reduced PPV without hepatic artery vasoconstriction and improved post-operative UOP.

  19. The haemodynamic effects of the perioperative terlipressin infusion in living donor liver transplantation: A randomised controlled study

    Science.gov (United States)

    Ibrahim, Nagwa; Hasanin, Ashraf; Allah, Sabry Abd; Sayed, Eman; Afifi, Mohamed; Yassen, Khaled; Saber, Wesam; Khalil, Magdy

    2015-01-01

    Background and Aims: Liver disease is usually accompanied with a decline in systemic vascular resistance (SVR). We decided to assess effects of the peri-operative terlipressin infusion on liver donor liver transplantation recipients with respect to haemodynamics and renal parameters. Methods: After Ethical Committee approval for this prospective randomised controlled study, 50 recipients were enrolled and allotted to control (n = 25) or terlipressin group (n = 25) with simple randomisation method. Terlipressin was infused at 1.0 μg/kg/h and later titrated 1.0–4.0 μg/kg/h to maintain mean arterial pressure (MAP) >65 mmHg and SVR index 0.05) and was sustained post-operatively. Conclusion: Terlipressin improved SVR and MAP with less need for catecholamines particularly post-reperfusion. Terlipressin reduced PPV without hepatic artery vasoconstriction and improved post-operative UOP. PMID:25838587

  20. Earliest Deadline Control of a Group of Heat Pumps with a Single Energy Source

    Directory of Open Access Journals (Sweden)

    Jiří Fink

    2016-07-01

    Full Text Available In this paper, we develop and investigate the optimal control of a group of 104 heat pumps and a central Combined Heat and Power unit (CHP. The heat pumps supply space heating and domestic hot water to households. Each house has a buffer for domestic hot water and a floor heating system for space heating. Electricity for the heat pumps is generated by a central CHP unit, which also provides thermal energy to a district heating system. The paper reviews recent smart grid control approaches for central and distributed levels. An online algorithm is described based on the earliest deadline first theory that can be used on the aggregator level to control the CHP and to give signals to the heat pump controllers if they should start or should wait. The central controller requires only a limited amount of privacy-insensitive information from the heat pump controllers about their deadlines, which the heat pump controllers calculate for themselves by model predictions. In this way, a robust heat pump and CHP control is obtained, which is able to minimize energy demand and results in the desired thermal comfort for the households. The simulations demonstrate fast computation times due to minor computational and communication overheads.

  1. Thermostat-controlled coolant pump - a new concept for fuel saving

    Energy Technology Data Exchange (ETDEWEB)

    Etemad, S. [Volvo Car Components Corp., Gothenburg (Sweden); Anderson, A. [Volvo Truck Corp., Gothenburg (Sweden)

    1999-07-01

    A new coolant pump concept has been developed for better fuel economy. The flow returning from the radiator is fed coaxially into the pump. The by-pass flow is fed tangentially into the pump, generating a pre-swirl with the same direction of rotation as the coolant pump impeller. The relative velocity between the flow and the impeller decreases. This reduces the transferred momentum from the impeller to the fluid, reducing the power consumption. The flow split between the radiator and the by-pass channel is controlled by the ordinary thermostat. Results from analysis and measurements are presented. (author)

  2. A pharmacodynamic analysis of factors affecting recovery from anesthesia with propofol-remifentanil target controlled infusion

    Institute of Scientific and Technical Information of China (English)

    Bon-nyeo KOO; Jeong-rim LEE; Gyu-jeong NOH; Jae-hoon LEE; Young-ran KANG; Dong-woo HAN

    2012-01-01

    Aim:To examine individual patient's demographic parameters and clinical variables related to return of consciousness (ROC) and the pharmacodynamic relationship between propofol effect-site concentration (Ce) and ROC from propofol-remifentanil anesthesia.Methods:Ninety-four patients received propofol-remifentanil anesthesia using the effect-site target-controlled infusion (TCI) system.All clinical events were noted,and variables possibly related to propofol Ce at ROC were examined using linear correlation analyses.Pharmacodynamic modeling incorporating covariates was performed using NONMEM (Nonlinear Mixed Effects Modeling) Ⅶ software.Results:The Ce values of propofol at loss of consciousness (LOC) and ROC were 4.4±1.1 μg/mL and 1.1±0.3 μg/mL respectively.Age was negatively correlated with propofol Ce at ROC (r=-0.48,P<0.01).Including age as a covariate in Ce50 (the effect-site concentration associated with 50% probability of return of consciousness) and λ (the steepness of the concentration-versus-response relationship) significantly improved the performance of the basic model based on the likelihood ratio test,with a significant decrease in the minimum value of the objective function.The Ce50 in 25-,50-,and 75-year-old patients was predicted to be 1.38,1.06,and 0.74 Iμg/mL,respectively.The λ,in 25-,50-,and 75-year-old patients was predicted to be 12.23,8.70,and 5.18,respectively.Conclusion:Age significantly affects the relationship between propofol Ce and ROC,and pharmacodynamic modeling including age could lead to better predictions of ROC during emergence from propofol-remifentanil anesthesia.

  3. Bispectral index for monitoring anesthetic depth in patients with severe burns receiving target-controlled infusion of remifentanil and propofol.

    Science.gov (United States)

    Guo, Z G; Jia, X P; Wang, X Y; Li, P; Su, X J; Hao, J H

    2015-07-13

    This study evaluated the feasibility and effectiveness of using the bispectral index (BIS) to monitor anesthetic depth in patients with severe burns receiving intravenous target-controlled infusion (TCI) of remifentanil and propofol. We randomly assigned 80 patients undergoing elective escharectomy (depth in patients with severe burns receiving TCI of remifentanil and propofol during the perioperative period reduces propofol consumption and shortens the consciousness recovery time in patients.

  4. Demonstration of a Low-Lift Heat Pump for High-Power Spacecraft Thermal Control

    Science.gov (United States)

    Grzyll, Lawrence R.

    2006-01-01

    This paper describes the development and demonstration of a prototype low-lift heat pump for high-power spacecraft thermal control The low-lift heat pump was designed to provide 25 kW of cooling at 303 K and transport this waste heat to a radiator for heat rejection. To accomplish this, a demonstration heat pump with an evaporation temperature of 298 K and a condensing temperature of 301 K was designed and built. HFC-227ea was the working fluid. This effort resulted in optimization of the centrifugal compressor impeller, diffuser, and shroud designs through extensive experimental testing. The detailed design of a magnetic bearing centrifugal compressor was completed. A prototype heat pump thermal control system was designed and fabricated which contained prototypical cold plate and condenser designs. This prototype system was extensively tested and demonstrated to measure performance parameters such as power consumption, cooling capacity, system size and mass, and other key parameters. Finally, the experimental performance was input into the theoretical trade study allowing for a comparison of the actual performance of the low-lift heat pump to a single-phase pumped loop. Inputting the experimental low-lift heat pump performance into the trade study showed that the low-lift heat pump still has lower system mass than the single-phase pumped loop for all space temperatures considered. The experimental results very closely match the theoretical results used in the trade study.

  5. AUTOMATIC CONTROL SYSTEM OF HEAT PUMP STATION GAS COOLER AT THE WIDE RANGE OF HEAT LOAD

    Directory of Open Access Journals (Sweden)

    Juravleov A.A.

    2008-08-01

    Full Text Available There is examined the structure the of control system of gas cooler of heat pump station, which uses the carbon dioxide as the working fluid in the transctitical thermodynamical cycle. It is analiyed the structure of the complex: heat pump station – district heating system.

  6. Earliest Deadline Control of a Group of Heat Pumps with a Single Energy Source

    NARCIS (Netherlands)

    Fink, J.; van Leeuwen, Richard Pieter

    2016-01-01

    In this paper, we develop and investigate the optimal control of a group of 104 heat pumps and a central Combined Heat and Power unit (CHP). The heat pumps supply space heating and domestic hot water to households. Each house has a buffer for domestic hot water and a floor heating system for space h

  7. Earliest Deadline Control of a Group of Heat Pumps with a Single Energy Source

    NARCIS (Netherlands)

    Fink, J.; van Leeuwen, Richard Pieter

    2016-01-01

    In this paper, we develop and investigate the optimal control of a group of 104 heat pumps and a central Combined Heat and Power unit (CHP). The heat pumps supply space heating and domestic hot water to households. Each house has a buffer for domestic hot water and a floor heating system for space

  8. Temperature and Humidity Independent Control Research on Ground Source Heat Pump Air Conditioning System

    Science.gov (United States)

    Chen, G.; Wang, L. L.

    Taking green demonstration center building air conditioning system as an example, this paper presents the temperature and humidity independent control system combined with ground source heat pump system, emphasis on the design of dry terminal device system, fresh air system and ground source heat pump system.

  9. Improving the Efficiency of the Heat Pump Control System of Carbon Dioxide Heat Pump with Several Evaporators and Gas Coolers

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2016-12-01

    Full Text Available The problem of coordination of the values of the refrigerant flow through the evaporators and gas coolers of the heat pump for the simultaneous production of heat and cold is studied. The compensation of the variations of the total flow through the evaporators is implemented using the variation of the capacity of the compressor and a corresponding change in flow through the auxiliary gas cooler of the heat pump. Control system of this gas cooler is constructed using the invariance principle of the output value (outlet temperature of the heated agent with respect to perturbations on the control channel (the refrigerant flow through the gas cooler. Principle of dual-channel compensation of the disturbance and advancing signal on input of control valve of the refrigerant through the gas cooler is ensured. Due to proposed solution, the intensity of the disturbances on the flow of refrigerant is reduced. Due to proposed technical solution power consumed by the heat pump compressor drive under transients is decreased.

  10. Long-Term Effects of Neonatal Morphine Infusion on Pain Sensitivity: Follow-Up of a Randomized Controlled Trial.

    Science.gov (United States)

    Valkenburg, Abraham J; van den Bosch, Gerbrich E; de Graaf, Joke; van Lingen, Richard A; Weisglas-Kuperus, Nynke; van Rosmalen, Joost; Groot Jebbink, Liesbeth J M; Tibboel, Dick; van Dijk, Monique

    2015-09-01

    Short-term and long-term effects of neonatal pain and its analgesic treatment have been topics of translational research over the years. This study aimed to identify the long-term effects of continuous morphine infusion in the neonatal period on thermal pain sensitivity, the incidence of chronic pain, and neurological functioning. Eighty-nine of the 150 participants of a neonatal randomized controlled trial on continuous morphine infusion versus placebo during mechanical ventilation underwent quantitative sensory testing and neurological examination at the age of 8 or 9 years. Forty-three children from the morphine group and 46 children from the placebo group participated in this follow-up study. Thermal detection and pain thresholds were compared with data from 28 healthy controls. Multivariate analyses revealed no statistically significant differences in thermal detection thresholds and pain thresholds between the morphine and placebo groups. The incidence of chronic pain was comparable between both groups. The neurological examination was normal in 29 (76%) of the children in the morphine group and 25 (61%) of the children in the control group (P = .14). We found that neonatal continuous morphine infusion (10 μg/kg/h) has no adverse effects on thermal detection and pain thresholds, the incidence of chronic pain, or overall neurological functioning 8 to 9 years later. Perspective: This unique long-term follow-up study shows that neonatal continuous morphine infusion (10 μg/kg/h) has no long-term adverse effects on thermal detection and pain thresholds or overall neurological functioning. These findings will help clinicians to find the most adequate and safe analgesic dosing regimens for neonates and infants.

  11. Liquid metal flow control by DC electromagnetic pumps; Controle de vazao de metais liquidos por bombas eletromagneticas de corrente continua

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Eduardo Madeira; Braz Filho, Francisco Antonio; Guimaraes, Lamartine Nogueira Frutuoso [Instituto de Estudos Avancados (IEAv), Sao Jose dos Campos, SP (Brazil)], e-mail: eduardo@ieav.cta.br, e-mail: fbraz@ieav.cta.br, e-mail: guimarae@ieav.cta.br

    2006-07-01

    The cooling system of high-density thermal power requires fluids of high thermal conductivity, such as liquid metals. Electromagnetic pumps can be used to liquid metal fluid flow control in cooling circuits. The operation of electromagnetic pumps used to flow control is based on Lorentz force. This force can be achieved by magnetic field and electric current interaction, controlled by external independent power supplies. This work presents the electromagnetic pump operational principles, the IEAv development scheme and the BEMC-1 simulation code. The theoretical results of BEMC-1 simulation are compared to electromagnetic pump operation experimental data, validating the BEMC-1 code. This code is used to evaluate the DC electromagnetic pump performance applied to Mercury flow control and others liquid metal such as Sodium, Lead and Bismuth, used in nuclear fast reactors. (author)

  12. Advanced Control of Wind Electric Pumping System for Isolated Areas Application

    Directory of Open Access Journals (Sweden)

    Mohamed Barara

    2014-12-01

    Full Text Available The supply water in remote areas of windy region is one of most attractive application of wind energy conversion .This paper proposes an advanced controller suitable for wind-electric pump in isolated applications in order to have a desired debit from variation of reference speed of the pump also the control scheme of DC voltage of SIEG for feed the pump are presented under step change in wind speed. The simulation results showed a good performance of the global proposed control system.

  13. NaK flow control by electromagnetic pump of the SNAP-10A space nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Eduardo M.; Braz Filho, Francisco A.; Guimaraes, Lamartine N.F., E-mail: eduardo@ieav.cta.br, E-mail: fbraz@ieav.cta.br, E-mail: guimarae@ieav.cta.br [Instituto de Estudos Avancados (IEAv/DCTA), Sao Jose dos Campos, SP (Brazil)

    2013-07-01

    In the Institute for Advanced Studies (IEAv), were developed, successfully, the first two direct current electromagnetic pumps (DC EM pumps) of Brazil. The first was built with C-type magnet and coils; and the second, with Samarium-Cobalt permanent magnets, for magnetic field generation. Both were tested and performed quite satisfactory. The electromagnetic pump uses the Faraday principle, in which the interaction of the magnetic field and electric current generates the magneto-motive force, which produces the circulation of the fluid. This type of equipment may be used for controlling the liquid metal flow in nuclear space fast reactors. This paper shows the computer programs developed for design and evaluation of DC EM and electromagnetic thermoelectric (EMTE) pumps, the DC EM pump of Samarium-Cobalt magnets data to Mercury loop flow control, the EMTE pump of SNAP space nuclear reactor. It also compares the theoretical results to experimental data of NaK primary loop flow control by electromagnetic thermoelectric pump of the SNAP-10A space nuclear reactor, with satisfactory results, confirming the viability of the electromagnetic pumps evaluation scheme. (author)

  14. Continuous subcutaneous hydrocortisone infusion therapy in Addison's disease: a randomized, placebo-controlled clinical trial.

    Science.gov (United States)

    Gagliardi, Lucia; Nenke, Marni A; Thynne, Tilenka R J; von der Borch, Jenny; Rankin, Wayne A; Henley, David E; Sorbello, Jane; Inder, Warrick J; Torpy, David J

    2014-11-01

    Patients with Addison's disease (AD) report impaired subjective health status (SHS). Since cortisol exhibits a robust circadian cycle that entrains other biological clocks, impaired SHS may be due to the noncircadian cortisol profile achieved with conventional glucocorticoid replacement. Continuous subcutaneous hydrocortisone infusion (CSHI) reproduces a circadian cortisol profile, but its effects on SHS have not been objectively evaluated. The aim of this study was to determine the effect of CSHI on SHS in AD. This was a multicentre, double-blind, placebo-controlled trial of CSHI vs oral glucocorticoid therapy. Participants received in random order 4 weeks of: CSHI and oral placebo, and subcutaneous placebo and oral hydrocortisone, separated by a 2-week washout period. SHS was assessed using the Short-Form 36 (SF-36), General Health Questionnaire (GHQ-28), Fatigue Scale (FS), Gastrointestinal Symptom Rating Scale (GSRS); and Addison's Quality of Life Questionnaire (AddiQoL). Participants were asked their (blinded) treatment preference. Twenty-four hour urine free cortisol (UFC) and diurnal salivary cortisol collections compared cortisol exposure during each treatment. Ten participants completed the study. Baseline SHS scores (mean ± SE) were consistent with mild impairment: SF-36 physical component summary 48.4 (± 2.4), mental component summary 53.3 (± 3.0); GHQ-28 18.1 (± 3.3); GSRS 3.7 (± 1.6), and AddiQoL 94.7 (± 3.7). FS was similar to other AD cohorts 13.5 (± 1.0) (P = 0.82). UFC between treatments was not different (P = 0.87). The salivary cortisol at 0800 h was higher during CSHI (P = 0.03), but not at any other time points measured. There was no difference between the treatments in the SHS assessments. Five participants preferred CSHI, four oral hydrocortisone, and one was uncertain. Biochemical measurements indicate similar cortisol exposure during each treatment period, although a more circadian pattern was evident during CSHI. CSHI does not

  15. Target-controlled infusion and population pharmacokinetics of landiolol hydrochloride in patients with peripheral arterial disease

    Directory of Open Access Journals (Sweden)

    Kunisawa T

    2015-01-01

    this model was better than that of the previous model.Conclusion: The PK parameters of landiolol were best described by a two-compartment model with lag time. Distribution volume of the central compartment and total body clearance of landiolol in patients with peripheral arterial disease were approximately 64% and 84% of those in healthy volunteers, respectively. Keywords: landiolol hydrochloride, pharmacokinetics, target-controlled infusion, peripheral arterial disease, TCI, pharmacokinetic parameters, PAD

  16. Lack of difference between continuous versus intermittent heparin infusion on maintenance of intra-arterial catheter in postoperative pediatric surgery: a randomized controlled study

    Directory of Open Access Journals (Sweden)

    Maria Carolina Witkowski

    2013-12-01

    Full Text Available OBJECTIVE: To compare two systems of arterial catheters maintenance in postoperative pediatric surgery using intermittent or continuous infusion of heparin solution and to analyze adverse events related to the site of catheter insertion and the volume of infused heparin solution. METHODS: Randomized control trial with 140 patients selected for continuous infusion group (CIG and intermittent infusion group (IIG. The variables analyzed were: type of heart disease, permanence time and size of the catheter, insertion site, technique used, volume of heparin solution and adverse events. The descriptive variables were analyzed by Student's t-test and the categorical variables, by chi-square test, being significant p<0.05. RESULTS: The median age was 11 (0-22 months, and 77 (55% were females. No significant differences between studied variables were found, except for the volume used in CIG (12.0±1.2mL/24 hours when compared to IIG (5.3±3.5mL/24 hours with p<0.0003. CONCLUSIONS: The continuous infusion system and the intermittent infusion of heparin solution can be used for intra-arterial catheters maintenance in postoperative pediatric surgery, regardless of patient's clinical and demographic characteristics. Adverse events up to the third postoperative day occurred similarly in both groups. However, the intermittent infusion system usage in underweight children should be considered, due to the lower volume of infused heparin solution [ClinicalTrials.gov Identifier: NCT01097031].

  17. Lack of difference between continuous versus intermittent heparin infusion on maintenance of intra-arterial catheter in postoperative pediatric surgery: a randomized controlled study

    Science.gov (United States)

    Witkowski, Maria Carolina; de Moraes, Maria Antonieta P.; Firpo, Cora Maria F.

    2013-01-01

    OBJECTIVE: To compare two systems of arterial catheters maintenance in postoperative pediatric surgery using intermittent or continuous infusion of heparin solution and to analyze adverse events related to the site of catheter insertion and the volume of infused heparin solution. METHODS: Randomized control trial with 140 patients selected for continuous infusion group (CIG) and intermittent infusion group (IIG). The variables analyzed were: type of heart disease, permanence time and size of the catheter, insertion site, technique used, volume of heparin solution and adverse events. The descriptive variables were analyzed by Student's t-test and the categorical variables, by chi-square test, being significant p<0.05. RESULTS: The median age was 11 (0-22) months, and 77 (55%) were females. No significant differences between studied variables were found, except for the volume used in CIG (12.0±1.2mL/24 hours) when compared to IIG (5.3±3.5mL/24 hours) with p<0.0003. CONCLUSIONS: The continuous infusion system and the intermittent infusion of heparin solution can be used for intra-arterial catheters maintenance in postoperative pediatric surgery, regardless of patient's clinical and demographic characteristics. Adverse events up to the third postoperative day occurred similarly in both groups. However, the intermittent infusion system usage in underweight children should be considered, due to the lower volume of infused heparin solution [ClinicalTrials.gov Identifier: NCT01097031]. PMID:24473958

  18. Linear programming control of a group of heat pumps

    NARCIS (Netherlands)

    Fink, J.; van Leeuwen, Richard Pieter; Hurink, Johann L.; Smit, Gerardus Johannes Maria

    2015-01-01

    For a new district in the Dutch city Meppel, a hybrid energy concept is developed based on bio-gas co-generation. The generated electricity is used to power domestic heat pumps which supply thermal energy for domestic hot water and space heating demand of households. In this paper, we investigate di

  19. Computer system design description for the spare pump mini-dacs data acquisition and control system

    Energy Technology Data Exchange (ETDEWEB)

    Vargo, G.F. Jr.

    1994-09-29

    The attached document outlines the computer software design for the mini data acquisition and control system (DACS), that supports the testing of the spare pump for Tank 241-SY-101, at the maintenance and storage facility (MASF).

  20. Acceptance Test Procedure for New Pumping and Instrumentation Control Skid sup L sup

    CERN Document Server

    Koch, M R

    1999-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping and Instrumentation Control (PIC) skid designed as ''L''. The ATP will be performed after the construction of the PIC skid in the shop.

  1. Design, optimization, and deployment of a waterworks pumping station control system.

    Science.gov (United States)

    Borkowski, Dariusz; Wetula, Andrzej; Bień, Andrzej

    2012-07-01

    This article presents a summary of the development and realization of a custom control and monitoring system for a water supply facility consisting of fixed-capacity intake pumps, a reservoir tank, and variable-speed outtake pumps. Project realization included the design and building of control hardware, as well as the design and deployment of the intake pump switching algorithm. Details of the control system design with an emphasis on the pump switching algorithm are given. The stages of the system development, including process modeling, design goal formulation, optimization of control algorithm using genetic algorithms, simulation, and implementation, are presented. Finally, deployment and real-life results are shown. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.

  2. Blood glucose control in healthy subject and patients receiving intravenous glucose infusion or total parenteral nutrition using glucagon-like peptide 1

    DEFF Research Database (Denmark)

    Nauck, Michael A; Walberg, Jörg; Vethacke, Arndt

    2004-01-01

    It was the aim of the study to examine whether the insulinotropic gut hormone GLP-1 is able to control or even normalise glycaemia in healthy subjects receiving intravenous glucose infusions and in severely ill patients hyperglycaemic during total parenteral nutrition.......It was the aim of the study to examine whether the insulinotropic gut hormone GLP-1 is able to control or even normalise glycaemia in healthy subjects receiving intravenous glucose infusions and in severely ill patients hyperglycaemic during total parenteral nutrition....

  3. Precisión en flujo de infusión programado de bombas de nutrición enteral Precision in programmed infusion flow of enteral nutrition pumps

    Directory of Open Access Journals (Sweden)

    Juan Ignacio Padilla-Cuadra

    2008-09-01

    Full Text Available Justificación y objetivo: Se evaluó in vitro la precisión en el flujo de nutrición enteral en bombas peristálticas de nutrición enteral con el fin de determinar si ésta puede ser una variable que cause errores en la administración de la fórmula. Materiales y Métodos: Se evaluaron 13 bombas de infusión enteral del tipo peristáltico mediante la aplicación de un modelo de laboratorio que simulaba la administración a un paciente. Se usó para todos los casos una fórmula estándar diluida de la manera recomendada por el fabricante. Con un volumen meta de 240 mL. Se programó en cada bomba un flujo de infusión de 40 mL por hora. Para cada caso según el tiempo de infusión, se calculó el flujo de infusión real y a partir de la diferencia se calculó el porcentaje de error. Resultados: En 12 de las 13 bombas se detectó un error por exceso que fue de 7.5% hasta 52.5%. Solo una bomba, de marca distinta a todas las demás demostró un error de 0 mL/h con respecto a lo programado. Ninguna bomba mostró un déficit en el volumen de infusión. Conclusión: En la mayoría de las bombas evaluadas se detectó un porcentaje de error por exceso que supera lo estipulado por el fabricante.Justification and aim: To evaluate in vitro the accuracy of volume infusion of peristaltic enteral nutrition pumps to determine if this variable may be responsible for error’s in the administration of nutrition support. Materials and Methods: Thirteen pumps were evaluated through simulation using a model that resembles the administration of enteral nutrition to a patient. For every case, we used an standard formula diluted as recommended by the manufacturer. A volume of 240 mL was programmed to be infused at 40 ml per hour. For each case, time was measured until finishing the volume, comparing to the programmed time and calculating the delivery error. Results: In 12 of 13 pumps, we detected error by excess, which varied from 7.5% to 52.5%. Only one pump showed

  4. Auto-control of pumping operations in sewerage systems by rule-based fuzzy neural networks

    Science.gov (United States)

    Chiang, Y.-M.; Chang, L.-C.; Tsai, M.-J.; Wang, Y.-F.; Chang, F.-J.

    2011-01-01

    Pumping stations play an important role in flood mitigation in metropolitan areas. The existing sewerage systems, however, are facing a great challenge of fast rising peak flow resulting from urbanization and climate change. It is imperative to construct an efficient and accurate operating prediction model for pumping stations to simulate the drainage mechanism for discharging the rainwater in advance. In this study, we propose two rule-based fuzzy neural networks, adaptive neuro-fuzzy inference system (ANFIS) and counterpropagation fuzzy neural network for on-line predicting of the number of open and closed pumps of a pivotal pumping station in Taipei city up to a lead time of 20 min. The performance of ANFIS outperforms that of CFNN in terms of model efficiency, accuracy, and correctness. Furthermore, the results not only show the predictive water levels do contribute to the successfully operating pumping stations but also demonstrate the applicability and reliability of ANFIS in automatically controlling the urban sewerage systems.

  5. How Cells Can Control Their Size by Pumping Ions

    Directory of Open Access Journals (Sweden)

    Alan R. Kay

    2017-05-01

    Full Text Available The ability of all cells to set and regulate their size is a fundamental aspect of cellular physiology. It has been known for sometime but not widely so, that size stability in animal cells is dependent upon the operation of the sodium pump, through the so-called pump-leak mechanism (Tosteson and Hoffman, 1960. Impermeant molecules in cells establish an unstable osmotic condition, the Donnan effect, which is counteracted by the operation of the sodium pump, creating an asymmetry in the distribution of Na+ and K+ staving off water inundation. In this paper, which is in part a tutorial, I show how to model quantitatively the ion and water fluxes in a cell that determine the cell volume and membrane potential. The movement of water and ions is constrained by both osmotic and charge balance, and is driven by ion and voltage gradients and active ion transport. Transforming these constraints and forces into a set of coupled differential equations allows us to model how the ion distributions, volume and voltage change with time. I introduce an analytical solution to these equations that clarifies the influence of ion conductances, pump rates and water permeability in this multidimensional system. I show that the number of impermeant ions (x and their average charge have a powerful influence on the distribution of ions and voltage in a cell. Moreover, I demonstrate that in a cell where the operation of active ion transport eliminates an osmotic gradient, the size of the cell is directly proportional to x. In addition, I use graphics to reveal how the physico-chemical constraints and chemical forces interact with one another in apportioning ions inside the cell. The form of model used here is applicable to all membrane systems, including mitochondria and bacteria, and I show how pumps other than the sodium pump can be used to stabilize cells. Cell biologists may think of electrophysiology as the exclusive domain of neuroscience, however the electrical

  6. Manual versus target-controlled infusion of balanced propofol during diagnostic colonoscopy: A prospective randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Vučićević Vera

    2016-01-01

    Full Text Available Introduction. There is an increasing interest in balanced propofol sedation (BPS for colonoscopy in outpatient settings. Propofol is a potent anesthetic agent for this purpose and has a narrow therapeutic range, which increases a risk of cardiovascular and respiratory complications in case of improper administration. Objective. The aim of this study was to compare patients’ safety and comfort of endoscopists in two methods of BPS targeting deep sedation - propofol target-controlled infusion (TCI and manual intravenous titration technique (MT - during colonoscopy. Methods. This prospective randomized controlled trial included 90 patients (class I or II of the American Society of Anesthesiologists deeply sedated with propofol, coadministered with small doses of midazolam and fentanyl. Propofol was given by MT technique (45 patients or by TCI (45 patients. The following adverse effects were recorded: hypotension, hypertension, bradycardia, tachycardia, hypoxemia, bradypnea, apnea, hiccupping, and coughing, as well as endoscopist’s comfort during colonoscopy by means of a questionnaire. Results. The MT group compared to the TCI group had a lower mean arterial pressure in the 10th minute after the beginning (p = 0.017, and at the end of colonoscopy (p = 0.006, higher oxygen saturation in the fifth minute (p = 0.033, and in the 15th minute (p = 0.008 after the beginning of colonoscopy, and lower heart rate at the beginning of the procedure (p = 0.001. There were no statistically significant differences in adverse events. Endoscopist’s comfort during colonoscopy was high 95.6% in the TCI group vs. 88.9% in the MT group (p = 0.069. Conclusion. MT is clinically as stable as TCI of propofol for deep sedation during colonoscopy, and endoscopists experienced the same comfort during colonoscopy in both groups. Thus, both combinations are suitable for deep sedation during diagnostic colonoscopy.

  7. Energy-saving control model of inverter for centrifugal pump systems

    Directory of Open Access Journals (Sweden)

    Yin Luo

    2015-06-01

    Full Text Available The inverter control strategy is the key to pump energy-saving operation and should be established based on the current system configurations and system requirements, which is not the case in practice. As a result, the characteristics of pump system requirements and a combination pump with inverter were studied, and the mathematical models were established. A new model for an optimal inverter control strategy based on the current system configurations and system requirements was then established, and a method combining golden section search and genetic algorithm was formulated to solve this optimal model. This model sets up an optimal inverter control strategy to increase the efficiency of pump operation following a process line near the minimum requirements to improve operation conditions. The implementation difficulty of the control law was also reduced. Finally, the optimized model was applied to an industrial circulating pump system, and the result showed that the model can not only determine the optimal inverter control strategy but also evaluate the current operation situation of the pump configuration and determine the energy-saving potential for the current configuration, which can aid in the subsequent energy-saving reconstruction.

  8. Effect of Insulin Dilution on Lowering Glycemic Variability in Pump-Treated Young Children with Inadequately Controlled Type 1 Diabetes.

    Science.gov (United States)

    Mianowska, Beata; Fendler, Wojciech; Tomasik, Bartłomiej; Młynarski, Wojciech; Szadkowska, Agnieszka

    2015-09-01

    We investigated whether in young children with inadequately controlled type 1 diabetes and technical problems with continuous subcutaneous infusion of insulin at 100 units/mL the switch to insulin diluted to 10 units/mL (U10) can limit technical problems and improve glycemic control. Diluted U10 insulin was started in three children 3.8, 3.2, and 1.3 years old with a hemoglobin A1c (HbA1c) level (mean±SD) of 8.1±0.17% (65±1.7 mmol/mol) and insulin dose of 8.80±2.93 units/day. Patients were evaluated with continuous glucose monitoring (iPro™2; Medtronic Minimed, Northridge, CA) and a quality of life questionnaire (PedsQL™; www.pedsql.org/ ) and surveyed for pump-related problems at baseline and after 3 and 9 months of U10 insulin therapy. Continuous glucose monitoring records showed that glycemic variability assessed by SD and M100 decreased significantly (P=0.0085 and P=0.0482, respectively). HbA1c levels dropped to 7.3±1.00% (56±11.0 mmol/mol) after 3 months and to 6.7±0.55% (50±6.1 mmol/mol) after 9 months (P=0.12). Technical difficulties were minimized. These results suggest that the use of U10 insulin decreases glycemic variability and improves hampered pump therapy in young children with inadequately controlled type 1 diabetes.

  9. AUTOCLAVE INFUSION OF AEROSPACE RIBS BASED ON PROCESS MONITORING AND CONTROL BY ULTRASOUND SENSORS

    OpenAIRE

    Liebers, Nico; Buggisch, Manuel; Kleineberg, Markus; Wiedemann, Martin

    2015-01-01

    In this paper the manufacturing of a series of two wing carbon fiber reinforced ribs by an autoclave based infusion process is presented. The manufacturing concept is based on a low cost male aluminum tool, where the expected spring-in deformation was fed into the tool design. The spring-in angles were predicted by a novel pheno-numerical simulation. The manufacturing process was monitored by a network of a high number of ultrasound sensors, which were mounted on the bottom tool side and ...

  10. Controlling the Goos-Hänchen and Imbert-Fedorov shifts via pump and driving fields

    Science.gov (United States)

    Asiri, Saeed; Xu, Jingping; Al-Amri, M.; Zubairy, M. Suhail

    2016-01-01

    We consider a three-level atomic medium and discuss how to control the Goos-Hänchen (longitudinal) and Imbert-Fedorov (transverse) shifts for a circular polarized Gaussian beam via a pump field and a coherent driving field applied to the atomic medium. The susceptibility of the atomic medium can be adjusted by changing the driving and pump fields. Consequently, for a fixed driving field, by turning on and off the pump field the amplitude and the direction of the longitudinal and transverse shifts of such beam can be changed. We adopt stationary phase and beam simulation methods to derive our results.

  11. Variable Displacement Control of the Concrete Pumping System Based on Dynamic Programming

    Directory of Open Access Journals (Sweden)

    Ye Min

    2017-01-01

    Full Text Available To solve the problems of cylinder piston striking cylinder and the hydraulic shocking of the main pump, and causing energy waste problem, the method of variable displacement control of piston stroke was proposed. In order to achieve effective control of the piston stroke, variable displacement control model was established under the physical constraint condition of non-collision between piston and cylinder. And the control process was realized by Dynamic Programming(DP, the simulation and test results show that piston of concrete pumping system don’t strike cylinder and reduce the hydraulic shock of the main pump outlet, meanwhile improve the response speed of the cylinder and achieve energy-saving purposes under varying loads. This control model built in the integration design space of structure variable and control variable is of guiding significance for solving open-loop system’s engineering problems.

  12. A multicentre randomized controlled trial of an empowerment-inspired intervention for adolescents starting continuous subcutaneous insulin infusion--a study protocol.

    Science.gov (United States)

    Brorsson, Anna Lena; Leksell, Janeth; Viklund, Gunnel; Lindholm Olinder, Anna

    2013-12-20

    Continuous subcutaneous insulin infusion (CSII) treatment among children with type 1 diabetes is increasing in Sweden. However, studies evaluating glycaemic control in children using CSII show inconsistent results. The distribution of responsibility for diabetes self-management between children and parents is often unclear and needs clarification. There is much published support for continued parental involvement and shared diabetes management during adolescence. Guided Self-Determination (GSD) is an empowerment-based, person-centred, reflection and problem solving method intended to guide the patient to become self-sufficient and develop life skills for managing difficulties in diabetes self-management. This method has been adapted for adolescents and parents as Guided Self-Determination-Young (GSD-Y). This study aims to evaluate the effect of an intervention with GSD-Y in groups of adolescents starting on insulin pumps and their parents on diabetes-related family conflicts, perceived health and quality of life (QoL), and metabolic control. Here, we describe the protocol and plans for study enrollment. This study is designed as a randomized, controlled, prospective, multicentre study. Eighty patients between 12-18 years of age who are planning to start CSII will be included. All adolescents and their parents will receive standard insulin pump training. The education intervention will be conducted when CSII is to be started and at four appointments in the first 4 months after starting CSII. The primary outcome is haemoglobin A1c levels. Secondary outcomes are perceived health and QoL, frequency of blood glucose self-monitoring and bolus doses, and usage of carbohydrate counting. The following instruments will be used: Disabkids, 'Check your health', the Diabetes Family Conflict Scale and the Swedish Diabetes Empowerment Scale. Outcomes will be evaluated within and between groups by comparing data at baseline, and at 6 and 12 months after starting treatment. In this

  13. Closed-Loop Feedback Computer-Controlled Phenylephrine for Maintenance of Blood Pressure During Spinal Anesthesia for Cesarean Delivery: A Randomized Trial Comparing Automated Boluses Versus Infusion.

    Science.gov (United States)

    Ngan Kee, Warwick D; Tam, Yuk-Ho; Khaw, Kim S; Ng, Floria F; Lee, Shara W Y

    2017-07-01

    We previously described the use of closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure (BP) during spinal anesthesia for cesarean delivery. In this study, we report a modified system in which phenylephrine is delivered by intermittent boluses rather than infusion. We hypothesized that the use of computer-controlled boluses would result in more precise control of BP compared with infusions. Two hundred fourteen healthy patients having spinal anesthesia for elective cesarean delivery were randomized to have their systolic BP maintained by phenylephrine administered by computer-controlled continuous infusion or computer-controlled intermittent boluses. From induction of anesthesia until the time of uterine incision, a noninvasive BP monitor was set to cycle at 1-minute intervals. In the infusion group, the infusion rate was automatically adjusted after each BP measurement using a previously described algorithm. In the bolus group, the algorithm was modified so that the mass of drug that would have been delivered over 1 minute was instead injected as a rapid intravenous bolus after each BP measurement. The precision of BP control was assessed using performance error calculations and compared between groups, with the primary outcome defined as median absolute performance error, and the latter being a measure of inaccuracy showing an average of the magnitudes of the differences of measured BP values above or below the target values. The precision of BP control was greater, as shown by smaller values for median absolute performance error, in the bolus group (median 4.38 [quartiles 3.22, 6.25] %) versus the infusion group (5.39 [4.12, 7.04] %, P = .008). In the bolus group, phenylephrine consumption was smaller; this was associated with smaller values for median performance error compared with the continuous infusion group (P control was more precise when computer-controlled phenylephrine was delivered using intermittent

  14. The analgesic efficacy of intravenous lidocaine infusion after laparoscopic fundoplication: a prospective, randomized, double-blind, placebo-controlled trial

    Directory of Open Access Journals (Sweden)

    Dale GJ

    2016-12-01

    Full Text Available Gregory J Dale,1 Stephanie Phillips,2 Gregory L Falk3 1Westmead Hospital Clinical School, The University of Sydney, 2Sydney Adventist Hospital Clinical School, The University of Sydney, 3Concord Clinical School, The University of Sydney, Sydney, Australia Abstract: This study aimed to determine if intravenous lidocaine infusion reduces postoperative pain intensity following laparoscopic fundoplication surgery and to also validate the safety of intravenous lidocaine at the dose tested. This was an equally randomized, double-blind, placebo-controlled, parallel-group, single center trial. Adult patients undergoing laparoscopic fundoplication were recruited. The intervention group received 1 mg/kg intravenous lidocaine bolus prior to induction of anesthesia, then an intravenous infusion at 2 mg/kg/h for 24 hours. The primary outcome was pain, measured using a numeric rating scale for 30 hours postoperatively. Secondary outcomes were nausea and vomiting, opioid requirements, adverse events, serum lidocaine concentration, and length of hospital stay. The study was terminated after an interim analysis of 24 patients showed evidence of futility. There was no difference in postoperative pain scores (lidocaine versus control, mean ± standard deviation at rest (2.0 ± 2.7 vs 2.1 ± 2.4, P=0.286 or with movement (2.0 ± 2.6 vs 2.6 ± 2.7, P=0.487. Three adverse events occurred in the lidocaine group (25% of patients. Intravenous lidocaine did not provide clinically significant analgesia to patients undergoing laparoscopic fundoplication. The serum lidocaine concentration of patients who experienced adverse events were within the therapeutic range. This trial cannot confirm the safety of intravenous lidocaine at the dose tested. Keywords: analgesia, local anesthetics, intravenous infusions, pharmacokinetics

  15. Minimal sensor count approach to fuzzy logic rotary blood pump flow control.

    Science.gov (United States)

    Casas, Fernando; Ahmed, Nisar; Reeves, Andrew

    2007-01-01

    A rotary blood pump fuzzy logic flow controller without flow sensors was developed and tested in vitro. The controller, implemented in LabView, was set to maintain a flow set point in the presence of external pressure disturbances. Flow was estimated as a function of measured pump's delta P and speed, using a steady-state, nonlinear approximation. The fuzzy controller used the pump's flow estimate and delta P as feedback variables. The defuzzified control output manipulated the pump speed. Membership functions included flow error, delta P, and pump speed. Experimental runs in a mock loop (water/glycerin 3.5 cPs, 37 degrees C), using the estimated flow, were compared with those using a Transonic flow meter for nine conditions of flow and delta P (4 to 6 L/min, 150 to 350 mm Hg). Pressure disturbances generated by a servo pinch valve ranged from +/-23 to +/-47 mm Hg. Results indicated that the fuzzy controller ably regulated the flow set point to within +/-10% of the baseline even under large swings in pressure. There was no difference in controller performance between the ultrasonic flow measurement and the estimated flow calculation scenarios. These tests demonstrated that the fuzzy controller is capable of rejecting disturbances and regulating flow to acceptable limits while using a flow estimate.

  16. [Controlling of artificial blood pumps after total heart replacement - an example of disregulation (author's transl)].

    Science.gov (United States)

    Hennig, E; Affeld, K; Kless, H; Mohnhaupt, A; Mohhaupt, R; Clevert, D; Keibach, H; Krautzberger, W; Kleine, H O; Weidemann, H; Bücherl, E S

    1976-12-01

    This is a report on the special regulation problem of the left blood pump after replacement of the natural heart by incorporated extracorporally driven blood pumps in an animal experiment. The consequence of the peripheral self-regulation on the transporting capacity of the bloodpumps considering the driving pressure and the systemic pressure losses has been investigated. Two possible controlling principles and the respective fields of application are discussed on the example of a lung oedema.

  17. A research on an energy-saving software for pumping units based on FNN intelligent control

    Institute of Scientific and Technical Information of China (English)

    丁宝; 齐维贵; 王凤平

    2004-01-01

    An energy-saving scheme for pumping units via intermission start-stop performance is proposed. Because of the complexity of the oil extraction process, Fuzzy Neural Network (FNN) intelligent control is adopted. The structure of the Takagi-Sugeno (T-S) fuzzy neural network model is introduced and modified. FNNs are trained with sample information from oil fields and expert knowledge. Finally, pumping unit energy-saving FNN software, which cuts down power costs substantially, is presented.

  18. Absorption-free optical pumping spin control with the quantum Zeno effect

    CERN Document Server

    Nakanishi, T; Kitano, M

    2002-01-01

    We show that atomic spin motion can be controlled by circularly polarized light without light absorption in the strong pumping limit. In this limit, the pumping light, which drives the empty spin state, destroys the Zeeman coherence effectively and freezes the coherent transition via the quantum Zeno effect. It is verified experimentally that the amount of light absorption decreases asymptotically to zero as the incident light intensity is increased.

  19. Controlling Price-Responsive Heat Pumps for Overload Elimination in Distribution Systems

    DEFF Research Database (Denmark)

    Csetvei, Zsuzsa; Østergaard, Jacob; Nyeng, Preben

    2011-01-01

    This paper investigates the possibility of applying electric heat pumps with the control-by-price-concept in order to avoid overload in a local distribution system. The proposed control algorithm is based upon a centrally dispatched real-time market price, reflecting the state of a larger power...... system, and is extended with a local price control for overload elimination on the corresponding feeder. The paper presents the mathematical models of a two-node system with price-responsive heat pumps, the chosen methodology of the central price calculation, and the proposed local feedback control...

  20. Self-selected unrefined and refined carbohydrate diets do not affect metabolic control in pump-treated diabetic patients.

    Science.gov (United States)

    Venhaus, A; Chantelau, E

    1988-03-01

    This study investigated whether unrefined or refined carbohydrate diets have any effect on metabolic control and on insulin requirement in near-normoglycaemic Type 1 (insulin-dependent) diabetic out-patients on continuous subcutaneous insulin infusion therapy. Two females and 8 males (aged 27 +/- 9 years; diabetes duration 13 +/- 8 years; duration of insulin pump therapy 22 +/- 5 months; means +/- SD) participated in a randomised cross-over study with two 6-week periods on self-selected refined and unrefined carbohydrate diets respectively. As a result, energy intake differed between the experimental diets (2372 +/- 669 kcal/day on unrefined diet vs 2757 +/- 654 kcal/day on refined diet, p = 0.04), as did the fibre intake (18 +/- 5 g/day with the refined carbohydrate diet vs 35 +/- 13 g/day with the unrefined carbohydrate diet, p = 0.02). The composition of nutrients was approximately 40% carbohydrate, 45% fat, and 13% protein with both diets. Body weight, HbA1c, daily mean blood glucose (7.2 +/- 0.6 mmol/l) and serum lipids remained virtually unchanged during the entire study. Insulin requirement varied between 40.1 +/- 7.9 U/day with the unrefined carbohydrate diet, and 42.5 +/- 10.1 U/day with the refined carbohydrate diet (NS). Thus, neither the refined nor the unrefined carbohydrate diet affected insulin requirement and metabolic control in these near-normoglycaemic, normolipaemic, non-obese, insulin-pump-treated Type 1 diabetic patients.

  1. A novel technology for control of variable speed pumped storage power plant

    Institute of Scientific and Technical Information of China (English)

    Seyed Mohammad Hassan Hosseini; Mohammad Reza Semsar

    2016-01-01

    Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control (DTFC) of a variable speed pumped storage power plant (VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP’s control strategies is studied. At the first, a wind turbine with the capacity 2.2 kW and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts (including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter (2LVSC) and three-level voltage source converter (3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion (THD) and ripple of rotor torque and flux.

  2. Central model predictive control of a group of domestic heat pumps, case study for a small district

    NARCIS (Netherlands)

    Leeuwen, van R.P.; Fink, J.; Smit, G.J.M.; Helfert, Markus; Krempels, Karl-Heinz; Donnellan, Brian; Klein, Cornel

    2015-01-01

    In this paper we investigate optimal control of a group of heat pumps. Each heat pump provides space heating and domestic hot water to a single household. Besides a heat pump, each house has a buffer for domestic hot water and a floor heating system for space heating. The paper describes models and

  3. Central model predictive control of a group of domestic heat pumps, case study for a small district

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; Helfert, Markus; Krempels, Karl-Heinz; Donnellan, Brian; Klein, Cornel

    2015-01-01

    In this paper we investigate optimal control of a group of heat pumps. Each heat pump provides space heating and domestic hot water to a single household. Besides a heat pump, each house has a buffer for domestic hot water and a floor heating system for space heating. The paper describes models and

  4. Effect of perioperative intravenous lidocaine infusion on postoperative recovery following laparoscopic Cholecystectomy-A randomized controlled trial.

    Science.gov (United States)

    Song, Xiaoli; Sun, Yanxia; Zhang, Xiaomei; Li, Tianzuo; Yang, Binbin

    2017-09-01

    Intravenous lidocaine infusion has been shown to facilitate postoperative recovery after major abdominal surgery. The current randomized controlled study was performed to assess the effect of perioperative intravenous lidocaine infusion on pain intensity, bowel function and cytokine response after larparoscopic cholecystectomy. Eighty patients undergoing laparoscopic cholecystectomy were randomly allocated to receive intravenous lidocaine (bolus injection of 1.5 mg/kg lidocaine at induction of anesthesia, then a continuous infusion of 2 mg/kg/h until the end of surgery) or an equal volume of saline. Patients, anesthesiologists, and study personnel were blinded, and anesthesia and multimodal perioperative analgesia were standardized. Blood cytokines were measured at scheduled times within 48 h. Pain scores, opioid consumption, time to first flatus and time to first bowel movement were also measured after surgery. Seventy-one of the 80 patients who were recruited completed the study protocol. Patient demographics were similar in the two groups. Lidocaine significantly reduced pain intensity [visual analogue scale (VAS), 0-10 cm] at 2 h (lidocaine 3.01 ± 0.65 cm vs. placebo 4.27 ± 0.58 cm, p = 0.01) and 6 h (lidocaine 3.38 ± 0.42 cm vs. placebo 4.22 ± 0.67 cm, p = 0.01) and total fentanyl consumption 24 h after surgery (lidocaine 98.27 ± 16.33 μg vs. placebo 187.49 ± 19.76 μg, p = 0.005). Time to first flatus passage (lidocaine 20 ± 11 h vs. placebo 29 ± 10 h, p = 0.01) and time to first bowel movement (lidocaine 41 ± 16 h vs. placebo 57 ± 14 h, p = 0.01) were also significantly shorter in patients who received lidocaine. Intravenous lidocaine infusion experienced less cytokine release than the control group. This study indicates that perioperative systemic lidocaine improves postoperative recovery and attenuates the initiation of excessive inflammatory response following laparoscopic cholecystectomy

  5. Use of an implantable pump for controlled subcutaneous insulin delivery in healthy cats.

    Science.gov (United States)

    Zini, E; Padrutt, I; Macha, K; Riederer, A; Pesaresi, M; Lutz, T A; Reusch, C E

    2017-01-01

    The aim of this study was to examine the safety and reliability of a research-grade implantable pump for controlled delivery of insulin glargine in cats. For this purpose, a small telemetrically controlled drug delivery pump with a refillable reservoir was implanted into the subcutaneous tissues of the dorsal neck in 10 clinically healthy cats. The reservoir was filled with insulin glargine, and the pump was programmed to deliver four boluses of 0.25 IU/kg, 2-3 weeks apart. As a control, insulin glargine (0.25 IU/kg) was injected SC. Blood glucose and plasma insulin glargine concentrations were measured before each bolus and SC injection and for 8 h afterward. Cats were monitored for signs of discomfort. Pumps were easily implanted and well tolerated by all cats. The experiment was completed in five of 10 cats. In four, the pump failed because of technical reasons; another cat developed severe hypoglycaemia attributable to insulin leakage. Overall, plasma insulin glargine increased after six of eight (75%) initial boluses and after one of 16 (6%) successive boluses. Glucose decreased after seven of eight (88%) initial boluses and after four of 16 (25%) successive boluses. Only the first bolus significantly increased plasma insulin glargine (P = 0.008) and decreased glucose (P = 0.008). Of 20 SC injections, 10 (50%) increased plasma insulin glargine (P pump did not cause discomfort in cats, but life-threatening hypoglycaemia occurred in one. Frequent device problems suggest that the pump needs improvements. Because successive boluses did not increase plasma insulin glargine, this type of insulin may not be appropriate with the pump.

  6. A Model for the Application of Target-Controlled Intravenous Infusion for a Prolonged Immersive DMT Psychedelic Experience

    Science.gov (United States)

    Gallimore, Andrew R.; Strassman, Rick J.

    2016-01-01

    The state of consciousness induced by N,N-dimethyltryptamine (DMT) is one of the most extraordinary of any naturally-occurring psychedelic substance. Users consistently report the complete replacement of normal subjective experience with a novel “alternate universe,” often densely populated with a variety of strange objects and other highly complex visual content, including what appear to be sentient “beings.” The phenomenology of the DMT state is of great interest to psychology and calls for rigorous academic enquiry. The extremely short duration of DMT effects—less than 20 min—militates against single dose administration as the ideal model for such enquiry. Using pharmacokinetic modeling and DMT blood sampling data, we demonstrate that the unique pharmacological characteristics of DMT, which also include a rapid onset and lack of acute tolerance to its subjective effects, make it amenable to administration by target-controlled intravenous infusion. This is a technology developed to maintain a stable brain concentration of anesthetic drugs during surgery. Simulations of our model demonstrate that this approach will allow research subjects to be induced into a stable and prolonged DMT experience, making it possible to carefully observe its psychological contents, and provide more extensive accounts for subsequent analyses. This model would also be valuable in performing functional neuroimaging, where subjects are required to remain under the influence of the drug for extended periods. Finally, target-controlled intravenous infusion of DMT may aid the development of unique psychotherapeutic applications of this psychedelic agent. PMID:27471468

  7. A Model for the Application of Target-Controlled Intravenous Infusion for a Prolonged Immersive DMT Psychedelic Experience

    Directory of Open Access Journals (Sweden)

    Andrew Robert Gallimore

    2016-07-01

    Full Text Available The state of consciousness induced by N,N-dimethyltryptamine (DMT is one of the most extraordinary of any naturally-occurring psychedelic substance. Users consistently report the complete replacement of normal subjective experience with a novel alternate universe, often densely populated with a variety of strange objects and other highly complex visual content, including what appear to be sentient beings. The phenomenology of the DMT state is of great interest to psychology and calls for rigorous academic enquiry. The extremely short duration of DMT effects—less than 20 minutes—militates against single dose administration as the ideal model for such enquiry. Using pharmacokinetic modelling and DMT blood sampling data, we demonstrate that the unique pharmacological characteristics of DMT, which also include a rapid onset and lack of acute tolerance to its subjective effects, make it amenable to administration by target-controlled intravenous infusion. This is a technology developed to maintain a stable brain concentration of anaesthetic drugs during surgery. Simulations of our model demonstrate that this approach will allow research subjects to be induced into a stable and prolonged DMT experience, making it possible to carefully observe its psychological contents, and provide more extensive accounts for subsequent analyses. This model would also be valuable in performing functional neuroimaging, where subjects are required to remain under the influence of the drug for extended periods. Finally, target-controlled intravenous infusion of DMT may aid the development of unique psychotherapeutic applications of this psychedelic agent.

  8. A Model for the Application of Target-Controlled Intravenous Infusion for a Prolonged Immersive DMT Psychedelic Experience.

    Science.gov (United States)

    Gallimore, Andrew R; Strassman, Rick J

    2016-01-01

    The state of consciousness induced by N,N-dimethyltryptamine (DMT) is one of the most extraordinary of any naturally-occurring psychedelic substance. Users consistently report the complete replacement of normal subjective experience with a novel "alternate universe," often densely populated with a variety of strange objects and other highly complex visual content, including what appear to be sentient "beings." The phenomenology of the DMT state is of great interest to psychology and calls for rigorous academic enquiry. The extremely short duration of DMT effects-less than 20 min-militates against single dose administration as the ideal model for such enquiry. Using pharmacokinetic modeling and DMT blood sampling data, we demonstrate that the unique pharmacological characteristics of DMT, which also include a rapid onset and lack of acute tolerance to its subjective effects, make it amenable to administration by target-controlled intravenous infusion. This is a technology developed to maintain a stable brain concentration of anesthetic drugs during surgery. Simulations of our model demonstrate that this approach will allow research subjects to be induced into a stable and prolonged DMT experience, making it possible to carefully observe its psychological contents, and provide more extensive accounts for subsequent analyses. This model would also be valuable in performing functional neuroimaging, where subjects are required to remain under the influence of the drug for extended periods. Finally, target-controlled intravenous infusion of DMT may aid the development of unique psychotherapeutic applications of this psychedelic agent.

  9. Improvement of photovoltaic pumping systems based on standard frequency converters by means of programmable logic controllers

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ramos, Jose [Departamento de Electronica, Universidad de Malaga, Complejo Tecnologico de Teatinos (2.2.39), 29071 Malaga (Spain); Narvarte-Fernandez, Luis; Poza-Saura, Fernando [Instituto de Energia Solar, Universidad Politecnica de Madrid (IES-UPM), Avenida Complutense s/n (204), 28040 Madrid (Spain)

    2010-01-15

    Photovoltaic pumping systems (PVPS) based on standard frequency converters (SFCs) are currently experiencing a growing interest in pumping programmes implemented in remote areas because of their high performance in terms of component reliability, low cost, high power range and good availability of components virtually anywhere in the world. However, in practical applications there have appeared a number of problems related to the adaptation of the SFCs to the requirements of the photovoltaic pumping systems (PVPS). Another disadvantage of dedicated PVPS is the difficulty in implementing maximum power point tracking (MPPT). This paper shows that these problems can be solved through the addition of a basic industrial programmable logic controller (PLC) to the system. This PLC does not increase the cost and complexity of the system, but improves the adaptation of the SFC to the photovoltaic pumping system, and increases the overall performance of the system. (author)

  10. Refrigerant Control Strategies for Residential Air-Conditioning and Heat-Pump System

    Institute of Scientific and Technical Information of China (English)

    SU Shun-yu; ZHANG Chun-zhi; CHEN Jian

    2009-01-01

    This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-con-ditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of dif-ferent refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-eonditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump-The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary.

  11. Temperature-controlled irrigated tip radiofrequency catheter ablation: comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, A;

    1998-01-01

    In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures <60% partly due to the limited lesion size after conventional radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion size, but has...... increased risk of cratering. The present study explores irrigated tip catheter ablation in temperature-controlled mode, target temperature 60 degrees C, using an irrigation rate of 1 mL/min, comparing this to conventional catheter technique, target temperature 80 degrees C.......In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures tip radiofrequency ablation using power control and high infusion rates enlarges lesion size, but has...

  12. Analysis of a micro-scale pump which uses controlled acoustic streaming for fluid locomotion

    Energy Technology Data Exchange (ETDEWEB)

    Dohner, J.L.

    1998-01-01

    In this report the analysis of a micro-scale pump is described. This micro-pump uses active control to produce a distributed body force in a fluid micro-channel. The desired effect of this body force is to drive fluid through the channel. Limitations, assumptions, and design parameters are discussed. The mathematical analysis of pump dynamics is explained in detail. A perturbation analysis is used on the equations of mass, momentum and state to produce equations of motion for first and second order effects. The first order effects are described by linear wave motion in the fluid and are found by using integral equation methods. The second order effects are driven by body forces resulting from first order effects. Thus, by controlling the production of wave motion in the channel, second order excitation can also be controlled. This report is all theory and therefore needs experimental validation. Although many of the assumptions used in this report have been used elsewhere in the literature and have been found to be sufficient, there are many aspects of the problem which have been left unresolved. In particular, flow separation in the fluid channel is a critical problem. If the fluid does not separate, pumping will occur through the channel, however, if internal or external forces are not sufficient to stop separation, this type of pump will not function.

  13. Microbial control of the dark end of the biological pump

    Science.gov (United States)

    Herndl, Gerhard J.; Reinthaler, Thomas

    2013-09-01

    A fraction of the carbon captured by phytoplankton in the sunlit surface ocean sinks to depth as dead organic matter and faecal material. The microbial breakdown of this material in the subsurface ocean generates carbon dioxide. Collectively, this microbially mediated flux of carbon from the atmosphere to the ocean interior is termed the biological pump. In recent decades it has become clear that the composition of the phytoplankton community in the surface ocean largely determines the quantity and quality of organic matter that sinks to depth. This settling organic matter, however, is not sufficient to meet the energy demands of microbes in the dark ocean. Two additional sources of organic matter have been identified: non-sinking organic particles of debated origin that escape capture by sediment traps and exhibit stable concentrations throughout the dark ocean, and microbes that convert inorganic carbon into organic matter. Whether these two sources can together account for the significant mismatch between organic matter consumption and supply in the dark ocean remains to be seen. It is clear, however, that the microbial community of the deep ocean works in a fundamentally different way from surface water communities.

  14. Microbial control of the dark end of the biological pump.

    Science.gov (United States)

    Herndl, Gerhard J; Reinthaler, Thomas

    2013-09-01

    A fraction of the carbon captured by phytoplankton in the sunlit surface ocean sinks to depth as dead organic matter and faecal material. The microbial breakdown of this material in the subsurface ocean generates carbon dioxide. Collectively, this microbially mediated flux of carbon from the atmosphere to the ocean interior is termed the biological pump. In recent decades it has become clear that the composition of the phytoplankton community in the surface ocean largely determines the quantity and quality of organic matter that sinks to depth. This settling organic matter, however, is not sufficient to meet the energy demands of microbes in the dark ocean. Two additional sources of organic matter have been identified: non-sinking organic particles of debated origin that escape capture by sediment traps and exhibit stable concentrations throughout the dark ocean, and microbes that convert inorganic carbon into organic matter. Whether these two sources can together account for the significant mismatch between organic matter consumption and supply in the dark ocean remains to be seen. It is clear, however, that the microbial community of the deep ocean works in a fundamentally different way from surface water communities.

  15. Sliding mode control for efficiency optimization of wind electrical pumping systems

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, R.D. [Universidad Nacional de la Patagonia (Argentina); Universidad Nacional de La Plata (Argentina); Mantz, R.J. [Comision de Investigaciones Cientificas de la Provincia de Buenos Aires (Argentina); Battatotto, P.E. [Universidad Nacional de La Plata (Argentina)

    2003-07-01

    Wind energy conversion systems have been receiving increasing attention in recent years, particularly in remote areas, where power from the utility is not available or is costly to install. Among many applications, wind electrical systems are successfully used for pumping water. Owing to the non-linear characteristics of these systems, their control is essential to attain high efficiency. In this work, concepts of sliding mode control are employed to guarantee global stability and to optimize the efficiency of a wind electrical water-pumping system. The measurement of wind speed is avoided. A thorough analysis of stability and dynamic behaviour is realized. Simulation results are presented. (Author)

  16. Safety and tolerability of an intravenously administered alpha1-proteinase inhibitor at an increased infusion rate: a novel, randomized, placebo-masked, infusion rate-controlled, crossover study in healthy adults

    Directory of Open Access Journals (Sweden)

    Ngo LY

    2014-06-01

    Full Text Available Leock Y Ngo,1 Adam Haeberle,1 Jacqueline Dyck-Jones,1 David Gelmont,1 Leman Yel11Baxter Healthcare Corporation, Westlake Village, CA, USAPurpose: Alpha1-proteinase inhibitor (A1PI is indicated for chronic augmentation therapy in adults with emphysema due to congenital deficiency of A1PI. An intravenous infusion rate of 0.04 mL/kg/minute is currently recommended for the A1PI product, Glassia®. This randomized, placebo-masked, rate-controlled, crossover study was designed to evaluate the safety and tolerability of A1PI administration at an increased infusion rate.Patients and methods: A total of 30 healthy male and female subjects aged 19–61 years were enrolled. Each subject received simultaneous intravenous infusions of A1PI (Glassia® and placebo (human albumin 2.5% administered through a single infusion site on two separate treatment periods. Subjects were randomized in a 1:1 ratio to receive either test treatment (A1PI 0.2 mL/kg/minute + placebo 0.04 mL/kg/minute, or reference treatment (A1PI 0.04 mL/kg/minute + placebo 0.2 mL/kg/minute on Day 1. On Day 15, subjects received the other treatment regimen in a crossover sequence.Results: A total of 36 adverse events (AEs, regardless of causality, were reported; all were non-serious and of mild intensity, with headaches and dizziness occurring most frequently (12 [33.3%] and three [8.3%] of 36 AEs, respectively. Only seven AEs in six subjects were assessed as related to study treatment: with two AEs reported in two subjects treated with the 0.2 mL/kg/minute rate compared with five AEs in four subjects treated with the 0.04 mL/kg/minute rate.Conclusions: This study demonstrated the safety and tolerability of an A1PI product at an increased infusion rate (0.2 mL/kg/minute resulting in a shorter infusion duration in healthy subjects.Keywords: A1PI, Glassia, administration rate, Alpha-1 antitrypsin, ATT

  17. Predictive performance of the Domino, Hijazi, and Clements models during low-dose target-controlled ketamine infusions in healthy volunteers

    NARCIS (Netherlands)

    Absalom, A. R.; Lee, M.; Menon, D. K.; Sharar, S. R.; De Smet, T.; Halliday, J.; Ogden, M.; Corlett, P.; Honey, G. D.; Fletcher, P. C.

    2007-01-01

    Background. Healthy volunteers received low-dose target-controlled infusions (TCI) of ketamine controlled by the Domino model while cognitive function tests and functional neuroimaging were performed. The aim of the current study was to assess the predictive performance of the Domino model during th

  18. Predictive performance of the Domino, Hijazi, and Clements models during low-dose target-controlled ketamine infusions in healthy volunteers

    NARCIS (Netherlands)

    Absalom, A. R.; Lee, M.; Menon, D. K.; Sharar, S. R.; De Smet, T.; Halliday, J.; Ogden, M.; Corlett, P.; Honey, G. D.; Fletcher, P. C.

    2007-01-01

    Background. Healthy volunteers received low-dose target-controlled infusions (TCI) of ketamine controlled by the Domino model while cognitive function tests and functional neuroimaging were performed. The aim of the current study was to assess the predictive performance of the Domino model during th

  19. INFUSION LOUNGE

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Infusion Lounge——颇具亚洲风情的的夜店——坐落于旧金山市区大受追捧的联合广场之上,福森酒店之下。此夜店兼具了酒吧与餐厅的功能,它将提供加州与亚洲风味融为一体的佳肴及优雅的环境和一流的服务。Infusion Lounge不仅为旧金山当地,也将为整个行业重新定义高消费夜生活的概念。

  20. Observation of anesthesia depth in severe burn patients with target controlled infusion of propofol and remifentanil by bispectral index

    Directory of Open Access Journals (Sweden)

    Zheng-gang GUO

    2012-04-01

    Full Text Available Objective To evaluate the feasibility and efficiency of bispectral index (BIS for monitoring the anesthesia depth of severe burn patients with target controlled infusion (TCI of propofol and remifentanil. Methods A total of 80 severe burns patients undergoing eschar excision ( < 1week were randomly divided into BIS group (group A and control group (group B, with 40 cases assigned in each group. These patients were 18 years to 65 years old, ASAⅡ-Ⅲ. Their total burn surface areas (TBSA were from 31% to 50%, or 11% to 20% with three-degree burns. All patients received remifentanil and propofol for TCI intravenous anesthesia. The mean arterial pressure (MAP and heart rate (HR were determined at following time points, namely, entrance to the operation room, loss of consciousness, 2min after intubation, before surgery, 2, 15, and 30min after the start of surgery, end of surgery, eye opening, and period when Aldrete score reaching 9 points, as well as the target concentrations of remifentanil and propofol. The time frames from stoppage of drug infusion to eye opening and the period when Aldrete score reaching 9 points were also recorded. Results Compared with group B, the target concentrations of remifentanil (2.12±0.35ng/ml vs. 2.50±0.21ng/ml and propofol (2.54±0.22μg/ml vs. 2.86±0.31μg/ml were significantly lower in group A during anesthetic maintenance (P < 0.01. The time interval from stoppage of drug infusion to eye opening (7.90±0.58min vs. 8.35±0.66min and period when Aldrete score reaching 9 points (9.15±0.69min vs. 11.13±0.96min were significantly reduced in group A. The MAP of both groups from loss of consciousness at all time points, except 2min after intubation, was significantly lower than the basic values upon entrance into the operation room (P < 0.05. The HR at all time points were significantly lower compared with the basic data (P < 0.05. Conclusion BIS for monitoring the anesthetic depth of severe burns patients

  1. A nationwide study of continuous subcutaneous insulin infusion (CSII) in Denmark

    DEFF Research Database (Denmark)

    Nørgaard, K

    2003-01-01

    AIMS: To record the number of patients treated with continuous subcutaneous insulin infusion (CSII), the attitude to CSII treatment among diabetes care providers and the characteristics of pump users in Denmark. METHODS: A questionnaire was mailed to all departments of endocrinology, internal...... that no more patients were interested and that it did not significantly improve metabolic control. The mean age of pump users was 48.1 +/- 10.5 years and the mean time wearing a pump 14.1 +/- 6.3 years. Mean HbA1c was 7.9 +/- 1.2% during CSII, with a significant difference among the 15 centres (P ....05) and a tendency to be lower in females (P = 0.07). CONCLUSIONS: CSII is infrequently used in Denmark despite pump users showing reasonably good metabolic control. The most common explanations for these low figures are lack of expertise and funding for CSII. If more patients in Denmark were to be offered pumps...

  2. The effect and nursing analysis of micro pump airway continuous infusion of asarone injection in the prevention of ventilator-associated pneumonia%微量泵持续气道滴注细辛脑注射液预防呼吸机相关性肺炎的效果及护理分析

    Institute of Scientific and Technical Information of China (English)

    蔡美容

    2013-01-01

    Objective To investigate the effect and nursing methods of micro pump airway continuous infusion of asarone injection in the prevention of ventilator-associated pneumonia (VAP).Methods A total of 66 patients with mechanical ventilation were divided into the observation group and the control group,the control group was used the traditional humidification fluid,the observation group was treated with micro pump continuous airway infusion of asarone injection; two groups were compared with airway humidification effect and the effects of mechanical ventilation.Results The irritating the phlegm scab formation,the number of times of sputum suction,heart rate,respiratory rate,C reactive protein,white blood cell count,neutrophil,body temperature,sputum culture in the observation group were significantly better than those in the control group (P < 0.05).And the incidence of VAP,partial pressure of oxygen,oxygen saturation,duration of hospitalization in the observation group were significantly better than those in the control group (P < 0.05).Conclusions Micro pump airway continuous infusion of asarone injection can effectively prevent the occurrence of VAP; Strengthen comprehensive nursing during the step of can improve the therapeutic effect.%目的 探讨微量泵持续气道滴注细辛脑注射液预防呼吸机相关性肺炎(VAP)的临床疗效及护理方法.方法 将66例机械通气的患者分为观察组和对照组,对照组采用传统湿化液,观察组采用微量泵持续气道滴细辛脑注射液,比较两组患者气道湿化的效果和机械通气的效果.结果 观察组的刺激性痰痂形成次数、吸痰次数、心率、呼吸频率、C反应蛋白、白细胞计数、中性粒细胞、体温、痰培养显著优于对照组(P<0.05),且观察组的VAP发生率、氧分压、血氧饱和度、住院时间显著优于对照组(P<0.05).结论 微量泵持续气道滴注细辛脑注射液可有效预防VAP的发生,期间加强综合护理可提高治疗效果.

  3. Wireless implantable chip with integrated nitinol-based pump for radio-controlled local drug delivery.

    Science.gov (United States)

    Fong, Jeffrey; Xiao, Zhiming; Takahata, Kenichi

    2015-02-21

    We demonstrate an active, implantable drug delivery device embedded with a microfluidic pump that is driven by a radio-controlled actuator for temporal drug delivery. The polyimide-packaged 10 × 10 × 2 mm(3) chip contains a micromachined pump chamber and check valves of Parylene C to force the release of the drug from a 76 μL reservoir by wirelessly activating the actuator using external radio-frequency (RF) electromagnetic fields. The rectangular-shaped spiral-coil actuator based on nitinol, a biocompatible shape-memory alloy, is developed to perform cantilever-like actuation for pumping operation. The nitinol-coil actuator itself forms a passive 185 MHz resonant circuit that serves as a self-heat source activated via RF power transfer to enable frequency-selective actuation and pumping. Experimental wireless operation of fabricated prototypes shows successful release of test agents from the devices placed in liquid and excited by radiating tuned RF fields with an output power of 1.1 W. These tests reveal a single release volume of 219 nL, suggesting a device's capacity of ~350 individual ejections of drug from its reservoir. The thermal behavior of the activated device is also reported in detail. This proof-of-concept prototype validates the effectiveness of wireless RF pumping for fully controlled, long-lasting drug delivery, a key step towards enabling patient-tailored, targeted local drug delivery through highly miniaturized implants.

  4. Ketamine Infusion Therapy as an Alternative Pain Control Strategy in Patients with Multi-Trauma including Rib Fracture; Case Report and Literature Review.

    Science.gov (United States)

    Losing, Ashley K; Jones, Justin M; Keric, Adis; Briggs, Steven E; Leedahl, David D

    2016-07-01

    Ketamine is a promising alternative agent for pain control that offers benefit to traditional strategies, particularly in the setting of rib fracture. Current pharmacologic therapies have clear adverse effects, and other options may be invasive, cost prohibitive, or marginally effective. We describe three consecutive patients with traumatic injuries including rib fracture for which a ketamine infusion was utilized as part of their pain control strategy.  For each patient, use of a ketamine infusion trended toward reduced opioid requirements with stable pain scores. One patient experienced a dissociative adverse effect prompting decrease and discontinuation of ketamine. No pulmonary complications in the form of emergent intubation or new diagnosis of pneumonia were observed. We believe the addition of ketamine infusion to be a valid alternative strategy for managing pain associated with rib fracture.

  5. Small-signal modelling and control of photovoltaic based water pumping system.

    Science.gov (United States)

    Ghosh, Arun; Ganesh Malla, Siva; Narayan Bhende, Chandrasekhar

    2015-07-01

    This paper studies small-signal modelling and control design for a photovoltaic (PV) based water pumping system without energy storage. First, the small-signal model is obtained and then, using this model, two proportional-integral (PI) controllers, where one controller is used to control the dc-link voltage and the other one to control the speed of induction motor, are designed to meet control goals such as settling time and peak overshoot of the closed loop responses. The loop robustness of the design is also studied. For a given set of system parameters, simulations are carried out to validate the modelling and the control design.

  6. Randomized, controlled, double-blind trial of topical lidocaine gel and intrauterine lidocaine infusion for pain relief during saline contrast sonohysterography.

    Science.gov (United States)

    Yung, S S F; Lai, S F; Lam, M T; Lee, V C Y; Li, R H W; Ho, P C; Ng, E H Y

    2016-01-01

    To evaluate the efficacy of topical lidocaine gel and intrauterine lidocaine infusion administered prior to saline contrast sonohysterography (SCSH) in reducing pain level during the procedure. This was a randomized, double-blind, placebo controlled trial. We recruited 120 women scheduled to undergo SCSH and randomized them into one of three groups according to administration of gel and intrauterine infusion immediately prior to the procedure: (1) the 'lidocaine gel' group received 3 mL 2% lidocaine gel applied to the cervix and intrauterine infusion, using an infant feeding tube without balloon, of 5 mL normal saline; (2) the 'lidocaine infusion' group received 3 mL gel lubricant applied to the cervix and intrauterine infusion of 5 mL 2% lidocaine; (3) the placebo group received 3 mL gel lubricant applied to the cervix and intrauterine infusion of 5 mL normal saline. The tube was left in place for the SCSH procedure. The primary outcome measure was the overall pain level (on a scale of 0-100) reported by the women during the SCSH procedure. Women also rated their pain levels at various other time points and an observer assessed visible signs of the women's discomfort during the procedure, producing a distress score. There were no significant differences among the three groups in baseline characteristics, volume of saline solution infused, tenaculum use and duration and difficulty level of the SCSH procedure. The median (range) pain scores during normal saline infusion for the SCSH procedure were 0 (0-65) in the placebo group, 2.5 (0-80) in the lidocaine gel group, and 0 (0-70) in the lidocaine infusion group. The pain scores at other time points, the overall pain score and the distress score were also comparable for the three groups. No significant adverse events were reported. SCSH performed with an infant feeding tube without balloon is associated with very low pain levels. Topical lidocaine gel application and intrauterine lidocaine infusion do not

  7. Central Control of Heat Pump for Smart Grid Purposes Tested on Single Family Houses

    DEFF Research Database (Denmark)

    Pedersen, Tom S.; Andersen, Palle; Nielsen, Kirsten M.

    2013-01-01

    A challenge in Denmark in the near future is to balance the electrical grid due to a large increase in the renewable energy production mainly from wind turbines. In this work a central control system using heat pumps in single family houses to help balancing the grid is investigated. The central...

  8. Test Report for Acceptance Test Procedure for Pumping and Instrumentation Control Skid ''K''

    CERN Document Server

    Johns, B R

    1999-01-01

    This is a Test Report for Acceptance Test Procedure (ATP) HNF-4276. This test report provides the results of the inspection and testing of the new Pumping and Instrumentation Control (PIC) skid designed as ''K''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document.

  9. Corrosion Control of Central Vehicle Wash Facility Pump Components Using Alternative Alloy Coatings

    Science.gov (United States)

    2016-07-01

    Fort Polk Directorate of Public Works • Richard Boillat and Colby Fox, Fort Polk Range Control The Commander of ERDC was COL Bryan S. Green and...Travel for project management $45,000 3 Cost of two new pumps (including taxes ) $88,750 4 Cost of new motor (including taxes ) $86,631 5 Coat

  10. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid N

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-03

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5489. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''N''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document.

  11. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid P

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-03-29

    This Acceptance Test Report (ATR) provides the test results for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''P''. The ATR summaries the results and provides a copy of the ATP and inspections in the Appendix.

  12. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid Q

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-05-11

    This Acceptance Test Report (ATR) provides the test results for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''Q''. The ATR summaries the results and provides a copy of the ATP and inspections in the Appendix.

  13. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid L

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    1999-11-09

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5055. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''L''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document.

  14. A predictive model for smart control of a domestic heat pump and thermal storage

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Gebhardt, I.; de Wit, J.B.; Smit, Gerardus Johannes Maria

    The purpose of this paper is to develop and validate a predictive model of a thermal storage which is charged by a heat pump and used for domestic hot water supply. The model is used for smart grid control purposes and requires measurement signals of flow and temperature at the inlet and outlet of

  15. Central Control of Heat Pump for Smart Grid Purposes Tested on Single Family Houses

    DEFF Research Database (Denmark)

    Pedersen, Tom S.; Andersen, Palle; Nielsen, Kirsten M.

    2013-01-01

    A challenge in Denmark in the near future is to balance the electrical grid due to a large increase in the renewable energy production mainly from wind turbines. In this work a central control system using heat pumps in single family houses to help balancing the grid is investigated. The central...

  16. A predictive model for smart control of a domestic heat pump and thermal storage

    NARCIS (Netherlands)

    Leeuwen, van R.P.; Gebhardt, I.; Wit, de J.B.; Smit, G.J.M.

    2016-01-01

    The purpose of this paper is to develop and validate a predictive model of a thermal storage which is charged by a heat pump and used for domestic hot water supply. The model is used for smart grid control purposes and requires measurement signals of flow and temperature at the inlet and outlet of t

  17. microcontroller based automatic control for water pumping machine ...

    African Journals Online (AJOL)

    user

    efforts to store and retrieve it when needed by the development of ... the challenges of achieving high energy efficiency and extended ... complexity, hence reduced high cost and energy .... Frequency Control", Jordan Journal of Mechanical.

  18. Auto-control of pumping operations in sewerage systems by rule-based fuzzy neural networks

    Directory of Open Access Journals (Sweden)

    Y.-M. Chiang

    2010-09-01

    Full Text Available Pumping stations play an important role in flood mitigation in metropolitan areas. The existing sewerage systems, however, are facing a great challenge of fast rising peak flow resulting from urbanization and climate change. It is imperative to construct an efficient and accurate operating prediction model for pumping stations to simulate the drainage mechanism for discharging the rainwater in advance. In this study, we propose two rule-based fuzzy neural networks, adaptive neuro-fuzzy inference system (ANFIS and counterpropagatiom fuzzy neural network (CFNN for on-line predicting of the number of open and closed pumps of a pivotal pumping station in Taipei city up to a lead time of 20 min. The performance of ANFIS outperforms that of CFNN in terms of model efficiency, accuracy, and correctness. Furthermore, the results not only show the predictive water levels do contribute to the successfully operating pumping stations but also demonstrate the applicability and reliability of ANFIS in automatically controlling the urban sewerage systems.

  19. Auto-control of pumping operations in sewerage systems by rule-based fuzzy neural networks

    Directory of Open Access Journals (Sweden)

    Y.-M. Chiang

    2011-01-01

    Full Text Available Pumping stations play an important role in flood mitigation in metropolitan areas. The existing sewerage systems, however, are facing a great challenge of fast rising peak flow resulting from urbanization and climate change. It is imperative to construct an efficient and accurate operating prediction model for pumping stations to simulate the drainage mechanism for discharging the rainwater in advance. In this study, we propose two rule-based fuzzy neural networks, adaptive neuro-fuzzy inference system (ANFIS and counterpropagation fuzzy neural network for on-line predicting of the number of open and closed pumps of a pivotal pumping station in Taipei city up to a lead time of 20 min. The performance of ANFIS outperforms that of CFNN in terms of model efficiency, accuracy, and correctness. Furthermore, the results not only show the predictive water levels do contribute to the successfully operating pumping stations but also demonstrate the applicability and reliability of ANFIS in automatically controlling the urban sewerage systems.

  20. Fault-tolerant strategies for an implantable centrifugal blood pump using a radially controlled magnetic bearing.

    Science.gov (United States)

    Pai, Chi Nan; Shinshi, Tadahiko

    2011-10-01

    In our laboratory, an implantable centrifugal blood pump (CBP) with a two degrees-of-freedom radially controlled magnetic bearing (MB) to support the impeller without contact has been developed to assist the pumping function of the weakened heart ventricle. In order to maintain the function of the CBP after damage to the electromagnets (EMs) of the MB, fault-tolerant strategies for the CBP are proposed in this study. Using a redundant MB design, magnetic levitation of the impeller was maintained with damage to up to two out of a total of four EMs of the MB; with damage to three EMs, contact-free support of the impeller was achieved using hydrodynamic and electromagnetic forces; and with damage to all four EMs, the pump operating point, of 5 l/min against 100 mmHg, was achieved using the motor for rotation of the impeller, with contact between the impeller and the stator.

  1. AUTOMATIC CONTROL SYSTEM FOR HEAT PUMP EMBEDDED IN INSTALLATION FOR PASTEURIZATION AND COOLING OF MILK, part I

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2012-12-01

    Full Text Available A heat pump scheme embedded into the installation for pasteurization and cooling of milk products is developed. A scheme of gas cooler automatic control system is considered. Methods of autonomous control of heat pump gas cooler and evaporators are presented as well.

  2. Modeling a high output marine steam generator feedwater control system which uses parallel turbine-driven feed pumps

    Institute of Scientific and Technical Information of China (English)

    QIU Zhi-qiang; ZOU Hai; SUN Jian-hua

    2008-01-01

    Parallel turbine-driven feedwater pumps are needed when ships travel at high speed. In order to study marine steam generator feedwater control systems which use parallel turbine-driven feed pumps,a mathematical model of marine steam generator feedwater control system was developed which includes mathematical models of two steam generators and parallel turbine-driven feed pumps as well as mathematical models of feedwater pipes and feed regulating valves. The operating condition points of the parallel turbine-driven feed pumps were calculated by the Chebyshev curve fit method. A water level controller for the steam generator and a rotary speed controller for the turbine-driven feed pumps were also included in the model. The accuracy of the mathematical models and their controllers was verified by comparing their results with those from a simulator.

  3. ROPIVACAINE CONTINUOUS WOUND INFUSION VERSUS CONTINUOUS EPIDURAL VERSUS SYSTEMIC ANALGESIA FOR POST CAESAREAN DELIVERY UNDER SPINAL ANAESTHESIA: A PROSPECTIVE RANDOMISED CONTROLLED STUDY

    Directory of Open Access Journals (Sweden)

    Paleti

    2014-07-01

    Full Text Available BACKGROUND: Opioid based analgesic regimens have been the gold standard for post caesarean analgesia until recently. Regional techniques like local intra-wound infusion techniques are becoming popular now. Our aim is to evaluate the efficacy of 0.2% Ropivacaine continuous wound infusion versus continuous epidural versus conventional systemic analgesia for post caesarean delivery. METHODOLOGY: 60 healthy parturients of ASA I/II were randomized after elective caesarean section into 3 groups of 20 each. Group-A: Received 0.2% Ropivacaine via an epidural catheter placed into subcutaneous tissue and fascia before skin closure at the rate of 5ml/hr. through infusion pump. Group-B: Received 0.2% Ropivacaine continuous epidural infusion via an epidural catheter at the rate of 8ml/hr. An initial bolus of 10ml was given in groups A&B. Group-C: Received standard systemic analgesia with diclofenac sodium and rescue opioid. Post operatively parturients were assessed for VAS scores for pain at rest and during movement, total Ropivacaine consumption, Tramadol consumption and side effects. Data were analyzed using SPSS software version 22. RESULTS: There were no significant differences in the mean VAS scores at rest and at movement between groups A or B and C. The consumption of Tramadol was significantly greater in Group C (p value AC=0.025, BC=0.0000 than A or B. Mean Ropivacaine consumption is significantly higher in Group B (p=0.000 than Group A. CONCLUSION: Continuous local intra-wound analgesia with Ropivacaine produced comparable analgesia to that of continuous epidural and superior analgesia compared to standard systemic analgesia.

  4. Low-cost feedback-controlled syringe pressure pumps for microfluidics applications

    Science.gov (United States)

    Lake, John R.; Heyde, Keith C.

    2017-01-01

    Microfluidics are widely used in research ranging from bioengineering and biomedical disciplines to chemistry and nanotechnology. As such, there are a large number of options for the devices used to drive and control flow through microfluidic channels. Commercially available syringe pumps are probably the most commonly used instruments for this purpose, but are relatively high-cost and have inherent limitations due to their flow profiles when they are run open-loop. Here, we present a low-cost ($110) syringe pressure pump that uses feedback control to regulate the pressure into microfluidic chips. Using an open-source microcontroller board (Arduino), we demonstrate an easily operated and programmable syringe pump that can be run using either a PID or bang-bang control method. Through feedback control of the pressure at the inlets of two microfluidic geometries, we have shown stability of our device to within ±1% of the set point using a PID control method and within ±5% of the set point using a bang-bang control method with response times of less than 1 second. This device offers a low-cost option to drive and control well-regulated pressure-driven flow through microfluidic chips. PMID:28369134

  5. Design and Implementation of Microcontroller Based SelfSwitching Control and Protection System for Twin Pumps

    Directory of Open Access Journals (Sweden)

    Hrudaynath Yelgudkar

    2016-07-01

    Full Text Available This paper apprises reader with a unique, modular and comprehensive control system designed using embedded systems approach (microcontroller based, primarily for efficient use of twin (two or couple of pumps working simultaneously in a given environment while constantly monitoring critical parameters such as current, voltage, temperature, water level in reservoir etc. for protection purposes. Though this control system is developed for pumps, it can be seamlessly adapted for controlling similar loads. We have developed the system using ATMmega-32 microcontroller of AVR family. The critical parameters were monitored using ADC port (analogto-digital-converter port of the microcontroller. Motivation behind developing this system was to replace classical „dedicated integrated circuit‟ based control system with more intelligent, compact, programmable and upgradable system besides lowering its cost aspects, using „embedded systems‟.

  6. Continuous intraperitoneal insulin infusion in type 1 diabetes : a 6-year post-trial follow-up

    NARCIS (Netherlands)

    van Dijk, Peter R.; Logtenberg, Susan J. J.; Groenier, Klaas H.; Gans, Rijk. O.B.; Kleefstra, Nanne; Bilo, Henk J. G.

    2014-01-01

    Background: Continuous intraperitoneal insulin infusion (CIPII) with an implantable pump is a treatment option for patients with type 1 diabetes mellitus (T1DM). Aim of the present study was to describe the long-term course of glycaemic control, complications, health related quality of life (HRQOL)

  7. Continuous intraperitoneal insulin infusion in type 1 diabetes : a 6-year post-trial follow-up

    NARCIS (Netherlands)

    van Dijk, Peter R.; Logtenberg, Susan J. J.; Groenier, Klaas H.; Gans, Rijk. O.B.; Kleefstra, Nanne; Bilo, Henk J. G.

    2014-01-01

    Background: Continuous intraperitoneal insulin infusion (CIPII) with an implantable pump is a treatment option for patients with type 1 diabetes mellitus (T1DM). Aim of the present study was to describe the long-term course of glycaemic control, complications, health related quality of life (HRQOL)

  8. Stimulation of insulin secretion by intravenous bolus injection and continuous infusion of gastric inhibitory polypeptide in patients with type 2 diabetes and healthy control subjects

    DEFF Research Database (Denmark)

    Meier, Juris J; Gallwitz, Baptist; Kask, Bartholomaeus

    2004-01-01

    in both healthy subjects and patients with type 2 diabetes. Eight patients with type 2 diabetes and eight healthy subjects participated in a 240-min hyperglycemic clamp (140 mg/dl) with intravenous infusion of placebo, GIP at a low dose, and GIP at a high dose, each administered continuously over 60 min....... Boluses of placebo, 20 pmol GIP/kg, and 80 pmol GIP/kg were injected intravenously at 0, 60, and 120 min, respectively. Capillary and venous blood was drawn for glucose, insulin, C-peptide, and GIP. Plasma insulin and C-peptide concentrations were lower in patients than in control subjects during all...... infusion periods. GIP bolus administration evoked a significant increase in plasma insulin levels in both patients with type 2 diabetes and healthy subjects. In contrast, the continuous GIP infusion led to a weak increase in insulin secretion in both healthy subjects and type 2 diabetic patients. The dose...

  9. The performance of a target-controlled infusion of propofol in combination with remifentanil : A clinical investigation with two propofol formulations

    NARCIS (Netherlands)

    Wietasch, JKG; Scholz, M; Zinserling, J; Kiefer, N; Frenkel, C; Knufermann, P; Brauer, U; Hoeft, A

    Target-controlled infusion (TCI) incorporates the pharmacokinetic variables of an IV drug to facilitate safe and reliable administration. In this clinical study we investigated the performance of propofol TCI in combination with remifentanil. Fifty-four adult patients scheduled for general surgery

  10. Effect of a high-dose target-controlled naloxone infusion on pain and hyperalgesia in patients following groin hernia repair

    DEFF Research Database (Denmark)

    Pereira, Manuel Pedro; Utke Werner, Mads; Berg Dahl, Joergen

    2015-01-01

    -dose target-controlled naloxone infusion can reinstate pain and hyperalgesia following recovery from open groin hernia repair and thus consistently demonstrate opioid-mediated latent sensitization in humans. METHODS/DESIGN: Patients submitted to unilateral, primary, open groin hernia repair will be included...

  11. Operational Test Report (OTR) for U-102 Pumping and Instrumentation and Control (PIC) Skid

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-28

    Attached is the completed Operation Test Procedure (OTP-200-004, Rev. A-19 and Rev. A-20). OTP includes a print out of the Programmable Logic Controller (PLC) Ladder Diagram. Ladder Diagram was designed for installation in the PLC used to monitor and control pumping activity for Tank Farm 241-U-102. The completed OTP and OTR are referenced in the IS PIC Skid Configuration Drawing (H-2-829998).

  12. Operational Test Report (OTR) for U-103 Pumping and Instrumentation and Control (PIC) Skid

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-28

    Attached is the completed Operation Test Procedure (OTP-200-004, Rev. A-16). OTP includes a print out of the Programmable Logic Controller (PLC) Ladder Diagram. Ladder Diagram was designed for installation in the PLC used to monitor and control pumping activity for Tank Farm 241-U-103. The completed OTP and OTR are referenced in the 25 PIC Skid Configuration Drawing (H-2-829998).

  13. Operational Test Report (OTR) for U-105 Pumping and Instrumentation and Control (PIC) Skid

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-28

    Attached is the completed Operation Test Procedure (OTP-200-004, Rev. A-18). OTP includes a print out of the Programmable Logic Controller (PLC) Ladder Diagram. Ladder Diagram was designed for installation in the PLC used to monitor and control pumping activity for Tank Farm 241-U-105. The completed OTP and OTR are referenced in the IS PIC Skid Configuration Drawing (H-2-829998).

  14. Energy Savings and Economics of Advanced Control Strategies for Packaged Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Huang, Yunzhi; Katipamula, Srinivas

    2012-10-31

    Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Program (BTP), evaluated a number of control strategies for packaged cooling equipment that can be implemented in an advanced controller, which can be retrofit into existing packaged heat pump units to improve their operational efficiency. This report documents the results of that analysis.

  15. Noninvasive activity-based control of an implantable rotary blood pump: comparative software simulation study.

    Science.gov (United States)

    Karantonis, Dean M; Lim, Einly; Mason, David G; Salamonsen, Robert F; Ayre, Peter J; Lovell, Nigel H

    2010-02-01

    A control algorithm for an implantable centrifugal rotary blood pump (RBP) based on a noninvasive indicator of the implant recipient's activity level has been proposed and evaluated in a software simulation environment. An activity level index (ALI)-derived from a noninvasive estimate of heart rate and the output of a triaxial accelerometer-forms the noninvasive indicator of metabolic energy expenditure. Pump speed is then varied linearly according to the ALI within a defined range. This ALI-based control module operates within a hierarchical multiobjective framework, which imposes several constraints on the operating region, such as minimum flow and minimum speed amplitude thresholds. Three class IV heart failure (HF) cases of varying severity were simulated under rest and exercise conditions, and a comparison with other popular RBP control strategies was performed. Pump flow increases of 2.54, 1.94, and 1.15 L/min were achieved for the three HF cases, from rest to exercise. Compared with constant speed control, this represents a relative flow change of 30.3, 19.8, and -15.4%, respectively. Simulations of the proposed control algorithm exhibited the effective intervention of each constraint, resulting in an improved flow response and the maintenance of a safe operating condition, compared with other control modes.

  16. A novel high-temperature and high-pressure hydraulic pump based on mononeuron control

    Institute of Scientific and Technical Information of China (English)

    Linhui ZHAO; Xin FANG

    2009-01-01

    Based on structures and characteristics of traditional hydraulic pumps, this paper proposes a novel high-temperature and high-pressure hydraulic pump (HHHP) that can work under 150℃ and 28MPa to overcome problems of traditional high-temperature plun-ger pumps. The HHHP is designed with the structure of mechanical division and double cylinder parallel. The control signals of two cylinders are two separate triangle waveforms with 90℃ phase difference. Because the output waveforms of two cylinders have the same characteristics as the control signals, the HHHP can obtain a stable output after two separate waveforms are superposed. A mono-neuron self-adaptive PID control algorithm is also improved by modifying parameters K and η. Two improved controllers are used to control the two cylinders,respectively, making two displacements of plungers match each other. Therefore, reduced fluctuations and stable pressure output is obtained. Besides simulation, tests on the built prototype test system are carried out to verify the performance of HHHP. Results show that the improved control approach can limit fluctuations to a lower level and the HHHP system attains good outputs under different signal periods and different pressures.

  17. A fuzzy controller for the VASPS (Vertical Annular Separation and Pumping System) subsea separation and pumping system; Um controlador fuzzy para o sistema de separacao e bombeamento submarino - VASP (Vertical Annular Separation and Pumping System)

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Alex F.; Mendes, Jose Ricardo P.; Morooka, Celso K. [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Mecanica. Dept. de Engenharia de Petroleo; Estevam, Valdir [PETROBRAS, Rio de Janeiro, RJ (Brazil); Guilherme, Ivan R. [UNESP, Rio Claro, SP (Brazil). Inst. de Geociencias e Ciencias Exatas. Dept. de Estatistica, Matematica Aplicada e Computacao; Rigo, Jose Eduardo [Centro Federal de Educacao Tecnologica no Espirito Santo (CEFETES), Vitoria, ES (Brazil)

    2004-07-01

    In this paper the designs of a fuzzy controller for the VASPS (Vertical Annular Separation and Pumping System) liquid level and separation pressure control are presented, as well as a simulation of its work to evaluate the performance of the controller designed. The VASPS is a two-phase subsea separation and pumping system, which is made up of a separation vessel, where the mixture (liquid and gas) enters and suffers the separation process through three levels, the expansion chamber, the helix and the pool. The liquid inside the pool is taken to the platform using a pump that with a choke control the pool liquid level. The pool liquid level control is necessary because if the level exceeds the maximum value allowed, the liquid can invade the space occupied by the helix and hinder the separation process. An the other hand if the level is below the minimum allowed the pump can be damaged. The separation pressure control is important for operational security and efficiency issues, because when we keep the separation pressure near an optimum value we are maximizing its efficiency. With the controller and the simulator, many simulations of the work of system were made to get results that could be used to evaluate if the designed controller solved the problem and if its performance were satisfactory. After, a PID control system was designed to be used as comparison with the results obtained with the fuzzy controller, since the PID is widely used in the industrial environment. (author)

  18. A fuzzy controller for the VASPS (Vertical Annular Separation and Pumping System) subsea separation and pumping system; Um controlador fuzzy para o sistema de separacao e bombeamento submarino - VASP (Vertical Annular Separation and Pumping System)

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Alex F.; Mendes, Jose Ricardo P.; Morooka, Celso K. [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Mecanica. Dept. de Engenharia de Petroleo; Estevam, Valdir [PETROBRAS, Rio de Janeiro, RJ (Brazil); Guilherme, Ivan R. [UNESP, Rio Claro, SP (Brazil). Inst. de Geociencias e Ciencias Exatas. Dept. de Estatistica, Matematica Aplicada e Computacao; Rigo, Jose Eduardo [Centro Federal de Educacao Tecnologica no Espirito Santo (CEFETES), Vitoria, ES (Brazil)

    2004-07-01

    In this paper the designs of a fuzzy controller for the VASPS (Vertical Annular Separation and Pumping System) liquid level and separation pressure control are presented, as well as a simulation of its work to evaluate the performance of the controller designed. The VASPS is a two-phase subsea separation and pumping system, which is made up of a separation vessel, where the mixture (liquid and gas) enters and suffers the separation process through three levels, the expansion chamber, the helix and the pool. The liquid inside the pool is taken to the platform using a pump that with a choke control the pool liquid level. The pool liquid level control is necessary because if the level exceeds the maximum value allowed, the liquid can invade the space occupied by the helix and hinder the separation process. An the other hand if the level is below the minimum allowed the pump can be damaged. The separation pressure control is important for operational security and efficiency issues, because when we keep the separation pressure near an optimum value we are maximizing its efficiency. With the controller and the simulator, many simulations of the work of system were made to get results that could be used to evaluate if the designed controller solved the problem and if its performance were satisfactory. After, a PID control system was designed to be used as comparison with the results obtained with the fuzzy controller, since the PID is widely used in the industrial environment. (author)

  19. Convulsion during intra-arterial infusion of fasudil hydrochloride for the treatment of cerebral vasospasm following subarachnoid hemorrhage.

    Science.gov (United States)

    Enomoto, Yukiko; Yoshimura, Shinichi; Yamada, Kiyofumi; Iwama, Toru

    2010-01-01

    The incidence of convulsion and associated factors were retrospectively analyzed in 23 patients with symptomatic cerebral vasospasm following subarachnoid hemorrhage (SAH) who underwent a total of 31 intra-arterial infusion of fasudil hydrochloride (IAFH) procedures in 49 vessels. Fasudil hydrochloride was administered by superselective infusion via a microcatheter positioned at the proximal portion of the affected artery. Thirteen procedures were performed by manually controlled infusion of 30-75 mg fasudil hydrochloride (1.2-3.75 mg/ml) for approximately 10 minutes. Eighteen procedures were performed by continuous infusion of 60 mg fasudil hydrochloride (1.2 mg/ml) by infusion pump at a constant rate of 3 mg/min. Neurological improvement was observed after 18 of 22 procedures in patients with neurological deterioration due to vasospasm. Convulsion during IAFH developed in 4 patients, all treated by manual infusion (p convulsion during IAFH. IAFH was effective for treating cerebral vasospasm following aneurysmal SAH. IAFH at a constant rate of 3 mg/min delivered by infusion pump improved the symptoms of cerebral vasospasm and prevented convulsions during IAFH.

  20. A pilot study of factors associated with glycaemic control in adults with Type 1 diabetes mellitus on insulin pump therapy.

    Science.gov (United States)

    Wen, W; Frampton, R; Wright, K; Fattore, S; Shadbolt, B; Perampalam, S

    2016-02-01

    To identify the knowledge and management factors associated with glycaemic control among adults with Type 1 diabetes mellitus treated with insulin pump therapy. A cross-sectional study of adults with Type 1 diabetes mellitus on insulin pump therapy for at least 12 months (n = 50, 18-70 years old) was undertaken between December 2013 and May 2014. A new questionnaire was developed to evaluate participants' knowledge and management related to insulin pump therapy, and were correlated with insulin pump data, HbA1c and frequency of hypoglycaemia. Participants who changed their insulin pump settings when indicated had significantly better glycaemic control than those who did not (P = 0.04). Multivariate logistic regression analysis found that better overall insulin pump therapy management was a significant predictor of better glycaemic control (odds ratio 4.45, 95% confidence interval 1.61-12.3; P = 0.004) after adjusting for potential confounders including age, gender, duration of diabetes and insulin pump therapy. However, overall insulin pump therapy knowledge was not a significant predictor of glycaemic control (P = 0.058). There was no significant association between frequency of hypoglycaemia and insulin pump therapy knowledge or management. We identified some key knowledge and management factors associated with glycaemic control in adults with Type 1 diabetes mellitus on insulin pump therapy using a newly designed questionnaire. The pilot study assessed the clinical utility of this evaluation tool, which may facilitate provision of targeted education to insulin pump therapy users to achieve optimal glycaemic control. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.

  1. Analysis and control of flow at suction connection in high-speed centrifugal pump

    Directory of Open Access Journals (Sweden)

    Wen-wu Song

    2016-12-01

    Full Text Available The backflow vortexes at the suction connection in high-speed centrifugal pumps have negative effect on the flow field. Setting an orifice plate in front of the inducer is able to decrease the negative effect caused by backflow vortexes. The traditional plate is able to partially control the backflow vortexes, but a small part of the vortex is still in the inlet and the inducer. Four new types of orifice plates were created, and the control effects on backflow vortexes were analyzed. The ANSYS-CFX software was used to numerically simulate a high-speed centrifugal pump. The variations of streamline and velocity vectors at the suction connection were analyzed. Meanwhile, the effects of these plates on the impeller pressure and the internal flow field of the inducer were analyzed. Numerically, simulation and experimental data analysis methods were used to compare the head and efficiency of the high-speed pumps. The results show that the C-type orifice plate can improve the backflow vortex, reduce the low-pressure area, and improve the hydraulic performance of the high-speed pump.

  2. Gene expression profiling in circulating endothelial cells from systemic sclerosis patients shows an altered control of apoptosis and angiogenesis that is modified by iloprost infusion

    Science.gov (United States)

    2010-01-01

    Introduction Circulating endothelial cells are increased in patients affected by systemic sclerosis (SSc) and their number strongly correlates with vascular damage. The effects of iloprost in systemic sclerosis are only partially known. We aimed at studying the gene expression profile of circulating endothelial cells and the effects of iloprost infusion and gene expression in patients with systemic sclerosis. Methods We enrolled 50 patients affected by systemic sclerosis, 37 patients without and 13 patients with digital ulcers. Blood samples were collected from all patients before and 72 hours after either a single day or five days eight hours iloprost infusion. Blood samples were also collected from 50 sex- and age-matched healthy controls. Circulating endothelial cells and endothelial progenitors cells were detected in the peripheral blood of patients with systemic sclerosis by flow cytometry with a four-colour panel of antibodies. Statistical analysis was performed with the SPSS 16 statistical package.Circulating endothelial cells were then isolated from peripheral blood by immunomagnetic CD45 negative selection for the gene array study. Results The number of both circulating endothelial cells and progenitors was significantly higher in patients affected by systemic sclerosis than in controls and among patients in those with digital ulcers than in patients without them. Circulating endothelial cells and progenitors number increased after iloprost infusion. Gene array analysis of endothelial cells showed a different transcriptional profile in patients compared to controls. Indeed, patients displayed an altered expression of genes involved in the control of apoptosis and angiogenesis. Iloprost infusion had a profound impact on endothelial cells gene expression since the treatment was able to modulate a very high number of transcripts. Conclusions We report here that circulating endothelial cells in patients with systemic sclerosis show an altered expression of

  3. AZ-101 Mixer Pump Demonstration Data Acquisition System and Gamma Cart Data Acquisition Control System Software Configuration Management Plan

    Energy Technology Data Exchange (ETDEWEB)

    WHITE, D.A.

    1999-12-29

    This Software Configuration Management Plan (SCMP) provides the instructions for change control of the AZ1101 Mixer Pump Demonstration Data Acquisition System (DAS) and the Sludge Mobilization Cart (Gamma Cart) Data Acquisition and Control System (DACS).

  4. Postoperative pain management for arthroscopic shoulder surgery: interscalene block versus patient-controlled infusion of 0.25% bupivicaine.

    Science.gov (United States)

    Chao, David; Young, Shaun; Cawley, Patrick

    2006-05-01

    We compared an interscalene block with a patient-controlled regional anesthesia device (Pain Care 2000; Breg, Inc, Vista, Calif) for pain management after outpatient arthroscopic shoulder surgery (subacromial decompression as principal procedure). The 41 patients in this prospective study were randomized to receive either the block or the device. During the postoperative period, all patients in both groups received standardized oral medications and continuous cold therapy and used continuous passive motion machines. Patients were given diaries and instruction in making entries upon waking and before retiring on postoperative days 1, 2, 3, 5, and 10. Data collected were number of pain medications used each day; number of nighttime awakenings; and subjective pain, activity, and quality-of-life levels rated on a visual analog scale. All data were statistically analyzed with the Mann-Whitney test. Compared with patients using the block, patients using the device awoke significantly fewer times the first night after surgery (P = .023), were significantly more active during postoperative days 1 and 2 (Ps = .018, .042), and took significantly fewer pain medications on postoperative day 2 (P = .034). On all other measures, results were equivalent or were better with the device, though these findings were not statistically significant. Patient-controlled subacromial infusion of bupivicaine is an effective alternative to interscalene block for outpatient pain management after arthroscopic shoulder surgery.

  5. THEORETICAL AND EXPERIMENTAL STUDY ON THE PRESSURE AND VACUUM CONTINUOUS CONTROL SYSTEM BASED ON HYBRID PUMP

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A novel pressure and vacuum continuous control system, which adopts a hybrid pump as pressure and vacuum source, is presented. The mathematical model of the system is developed. The theoretical simulation and analysis on the system are implemented in order to study the relationships among the characteristics, parameters and working points of the system. The experimental investigations on the system characteristics are presented with the adoption of a fuzzy-PID controller. The simulation and experimental results indicate that the pressure and vacuum continuous control system based on hybrid pump has good dynamic and static performance, strong robustness and satisfactory adaptability to various system parameters. According to the results, system can successfully gain high accuracy and fast response signal. Also, the mathematical model of system is also testified by the experimental results.

  6. Design, Implementation and Evaluation of a Pump-Controlled Circuit for Single Rod Actuators

    Directory of Open Access Journals (Sweden)

    Ahmed Imam

    2017-02-01

    Full Text Available Pump-controlled hydraulic circuits are more efficient than valve-controlled circuits, as they eliminate the energy losses due to flow throttling in valves and require less cooling effort. Presently existing pump-controlled solutions for single rod cylinders encounter an undesirable performance during certain operating conditions. This paper investigates the performance issues in common pump-controlled circuits for the single rod actuators. Detailed analysis is conducted that identifies these regions in a load-velocity plane and the factors affecting them. The findings are validated by experimental results. A new design is then proposed that employs a limited throttling valve alongside two pilot operated check valves for differential flow compensation to improve the performance. The valve is of the flow control type and is chosen to have a throttling effect over critical regions; it has the least throttling over other operating regions, thus maintaining efficiency. Experimental work demonstrates improved performance in a full operating range of the actuator as compared to a circuit that uses only the pilot-operated check valves. This circuit is energy efficient and capable of recuperating energy.

  7. Insulin pump treatment in children and adolescents with type 1 diabetes.

    Science.gov (United States)

    Hofer, S; Meraner, D; Koehle, J

    2012-08-01

    Within children and adolescents with type 1 diabetes insulin pump treatment is of increasing interest. Frequency of insulin pump therapy shows a rapid and steep increase in toddlers and young children. Insulin pumps allow a close to physiologic insulin delivery due to basal rates programmed over 24 hours with circadian rhythms taken into account. Furthermore, another advantage of technical devices as insulin pumps is the application of extremely small amounts of insulin, as needed in very young children, with the possibility of titration of infusion rates down to 0.01E/h. Dawn Phenomenon and hypoglycemic events are main indications for insulin pump treatment in children and adolescents. A significant reduction of severe hypoglycemia, especially nocturnal hypoglycemia was shown, whereas a reduction of HbA1c and an improvement of metabolic control has been reported in short term and in some but not all long term studies. Ketoacidosis rate did not increase in insulin pump therapy. Complications due to continuous subcutaneous insulin infusion, like local infections and dermatological changes are frequent but were not associated with glycemic control and did not lead to discontinuation of insulin pump treatment. Pump discontinuation rate in general is low, varying from 1% in very young children up to 6% in pubertal adolescent girls. Insulin pump treatment was shown to be safe and efficient and the simplicity of handling the devices as well as an improvement of quality of life may explain the rapid increase of pump treatment in young children and adolescents with type 1 diabetes.

  8. Model predictive control of servo motor driven constant pump hydraulic system in injection molding process based on neurodynamic optimization

    Institute of Scientific and Technical Information of China (English)

    Yong-gang PENG; Jun WANG; Wei WEI

    2014-01-01

    In view of the high energy consumption and low response speed of the traditional hydraulic system for an injection molding machine, a servo motor driven constant pump hydraulic system is designed for a precision injection molding process, which uses a servo motor, a constant pump, and a pressure sensor, instead of a common motor, a constant pump, a pressure pro-portion valve, and a flow proportion valve. A model predictive control strategy based on neurodynamic optimization is proposed to control this new hydraulic system in the injection molding process. Simulation results showed that this control method has good control precision and quick response.

  9. A Pressure Control Method for Emulsion Pump Station Based on Elman Neural Network

    Directory of Open Access Journals (Sweden)

    Chao Tan

    2015-01-01

    Full Text Available In order to realize pressure control of emulsion pump station which is key equipment of coal mine in the safety production, the control requirements were analyzed and a pressure control method based on Elman neural network was proposed. The key techniques such as system framework, pressure prediction model, pressure control model, and the flowchart of proposed approach were presented. Finally, a simulation example was carried out and comparison results indicated that the proposed approach was feasible and efficient and outperformed others.

  10. The Effect of Vitamin B12 Infusion on Prevention of Nitrous Oxide-induced Homocysteine Increase: A Double-blind Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Alieh Zamani Kiasari

    2014-05-01

    Full Text Available Objective: Nitrous oxide is a common inhalation anesthetic agent in general anesthesia. While it is widely accepted as a safe anesthetic agent, evidence suggests exposure to this gas, leads to hyperhomocysteinemia. The present study aimed to evaluate the effects of single-dose intravenous infusions of vitamin B12, before and after the induction of nitrous oxide anesthesia on homocysteine levels after the surgery. Methods: This double-blind randomized controlled trial was conducted on 60 patients who were scheduled for elective surgery under general anesthesia, presumably lasting for more than two hours. The subjects were randomly allocated to three groups of 20. For the first group, vitamin B12 solution (1 mg/100 ml normal saline and 100 ml of normal saline (placebo, were infused before and after the induction of anesthesia, respectively. The second group received placebo and vitamin B12 infusion before and after the induction of anesthesia, respectively. The third group received placebo infusions at both times. Homocysteine levels were measured before and 24 hours after the surgery. Results: The mean homocysteine and vitamin B12 levels were significantly different within the three groups (p<0.001. In patients who had been infused with vitamin B12 before the surgery, homocysteine levels were significantly lower than the other two groups. In the placebo group, homocysteine levels significantly increased after the surgery. Conclusion: Nitrous oxide causes hyperhomocysteinemia after general anesthesia. Since vitamin B12 infusion is a safe and inexpensive method to decrease homocysteine levels in these patients, it may be recommended for patients undergoing nitrous oxide anesthesia to be used before induction of anesthesia.

  11. Parametric Optimization of Control Systems Pumping Station by the Genetic Algorithms

    Directory of Open Access Journals (Sweden)

    M. P. Dounaev

    2014-01-01

    Full Text Available Now the frequency regulation with its well-known advantages is becoming more popular for using in electric drives. One of these systems is the system of liquid flow stabilization for pumping station of the second flood, which is discussed at the article. There are functional elements of the system: the frequency converter, the induction motor, pump set, check valve, part of the pipeline between the flow sensors and PID controller. In this case are used PID controller with universal input and RS-485 OWEN TRM101.The article tries to solve the main problem, which is to set optimal controller settings. The article presents a mathematical model of the system, built on the basis of transfer functions. The specific values of the parameters for Bratsk pumping station of the second flood are found.To solve the problem of parametric optimization for control of pumping station authors use a genetic algorithm, which allows us to use different quality criteria. A set of parameters for the genetic algorithm is represented, as well as a method of selection and a method of the transition between generations. The problem of parametric optimization was solved by quadratic integral criterion and by the criterion, composed of direct measures of quality (regulation time and the overshoot. The PID controller optimal values of adjustable parameters were obtained both for considered criteria and for their corresponding transient processes. Comparative analysis of results was produced. When proving the optimality of the obtained settings for the quadratic criterion the proximity of the gradient components of the target functional to zero is demonstrated. In the case of a criterion based on a direct measure of quality, is presented a picture of convergence of adjustable parameters to the same value when run with different starting points.It is presented that the use of a criterion based on a direct measure of quality, can significantly reduce the overshoot with a

  12. Evaluation of Manufacturability of Embedded Sensors and Controls with Canned Rotor Pump System

    Energy Technology Data Exchange (ETDEWEB)

    Kisner, Roger A [ORNL; Fugate, David L [ORNL; Melin, Alexander M [ORNL; Holcomb, David Eugene [ORNL; Wilson, Dane F [ORNL; Silva, Pamela C [ORNL; Cruz Molina, Carola [ORNL

    2013-07-01

    This report documents the current status of fabrication and assembly planning for the magnetic bearing, canned rotor pump being used as a demonstration platform for deeply integrating I&C into nuclear power plant components. The report identifies material choices and fabrication sequences for all of the required parts and the issues that need to be either resolved or accommodated during the manufacturing process. Down selection between material options has not yet been performed. Potential suppliers for all of the necessary materials have also been identified. The assembly evaluation begins by logically subdividing the pump into modules, which are themselves decomposed into individual parts. Potential materials and fabrication processes for each part in turn are then evaluated. The evaluation process includes assessment of the environmental compatibility requirements and the tolerances available for the selected fabrication processes. A description of the pump power/control electronics is also provided. The report also includes exploded views of the modules that show the integration of the various parts into modules that are then assembled to form the pump. Emphasis has been placed on thermal environment compatibility and the part dimensional changes during heat-up. No insurmountable fabrication or assembly challenges have been identified.

  13. Economic COP Optimization of a Heat Pump with Hierarchical Model Predictive Control

    DEFF Research Database (Denmark)

    Tahersima, Fatemeh; Stoustrup, Jakob; Rasmussen, Henrik

    2012-01-01

    A low-temperature heating system is studied in this paper. It consists of hydronic under-floor heating pipes and an air/ground source heat pump. The heat pump in such a setup is conventionally controlled only by feed-forwarding the ambient temperature. Having shown >10% cut-down on electricity...... bills by involving feedback control in a previous study, this paper has continued the same line of argument and has investigated effects of a priori knowledge on weather forecast and electricity price profile to alleviate the total electricity cost subject to constraints on resident's thermal comfort......'s coefficient of performance. At the same time, it determines the actual temperature set-points of the rooms by deviating from the user-defined set-points within a thermal tolerance zone. Simulations results confirm significant cut-down on electricity bills without sacrificing resident thermal comfort...

  14. EFFECT OF INTRAOPERATIVE ESMOLOL INFUSION ON POSTOPERATIVE ANALGESIA IN LAPAROSCOPIC CHOLECYSTECTOMY PATIENTS: A RANDOMISED CONTROLLED TR IAL

    Directory of Open Access Journals (Sweden)

    Shreya

    2015-10-01

    Full Text Available BACKGROUND: Laparoscopic cholecystectomy, gaining worldwide popularity, can be performed on a short stay basis if postoperative pain is adequately addressed. Our present study determines the effect of intraoperative infusion of intravenous esmolol primarily in terms of postoperative analgesia and intraoperative haemodynamic stability. METHODS: 60 ASAPS 1 and 2 patients undergoing elective laparoscopic cholecystectomy were included in this randomi s ed, prospective, placebo - controlled clinical study. Patients were alloca ted into two groups to receive intraoperative intravenous esmolol (Group A, n=30 or normal saline (Group B, n=30 over a period of 10 minutes before induction. Intraoperative heart rate, mean arterial pressure and postoperative fentanyl requirement ( D uri ng first 6 postoperative hours were recorded. RESULTS: Postoperative requirement of fentanyl was significantly lower (92.73±17.42mcg in group A compared to 117.32±19.22mcg in group B, p value 0.05. CONCLUSION: Intravenous esmolol effectively reduces postoperative fentanyl requirement, thereby is a safe adjunct in the fie ld of postoperative analgesia for laparoscopic cholecystectomy.

  15. 医院注射泵质量控制检测分析与体会%Measurement of Syringe Pump Quality Control in Hospital

    Institute of Scientific and Technical Information of China (English)

    胡东涛; 杨明; 李双民

    2012-01-01

    Objective To analyze the problems encountered during quality control measurement of the syringe pump and point out the influencing factors for the measurement result. Methods Infutest 2000E Dual-Channel Infusion Device Analyzer from Swedish ALK Trade and Marketing was used for the measurement in different conditions. Results There was significant difference when the measurement condition changed. Conclusion The quality measurement of the syringe pump has to be performed with consideration to the clinical condition.%目的:分析注射泵质量控制检测中遇到的问题,提出影响注射泵质量检测结果判定的主要因素.方法:采用瑞典奥利科公司Infutest 2000E双通道注射泵/输液泵检测仪在不同条件下进行检测试验和对比测试.结果:在不同条件下注射泵检测结果会有很大差异.结论:注射泵的应用质量检测条件应结合临床实际.

  16. Controlled assembly of single colloidal crystals using electro-osmotic micro-pumps

    OpenAIRE

    Niu, Ran; Oğuz, Erdal C.; Müller, Hannah; Reinmüller, Alexander; Botin, Denis; Löwen, Hartmut; Palberg, Thomas

    2016-01-01

    We assemble charged colloidal spheres at deliberately chosen locations on a charged unstructured glass substrate utilizing ion exchange based electro-osmotic micro-pumps. Using microscopy, a simple scaling theory and Brownian Dynamics simulations, we systematically explore the control parameters of crystal assembly and the mechanisms through which they depend on the experimental boundary conditions. We demonstrate that crystal quality depends crucially on the assembly distance of the colloids...

  17. Comparative study between fast and slow induction of propofol given by target-controlled infusion: expected propofol concentration at the effect site. Randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Ricardo Francisco Simoni

    2015-04-01

    Full Text Available BACKGROUND AND OBJECTIVE: Studies have shown that the rate of propofol infusion may influence the predicted propofol concentration at the effect site (Es. The aim of this study was to evaluate the Es predicted by the Marsh pharmacokinetic model (ke0 0.26 min-1 in loss of consciousness during fast or slow induction. METHOD: The study included 28 patients randomly divided into two equal groups. In slow induction group (S, target-controlled infusion (TCI of propofol with plasma, Marsh pharmacokinetic model (ke0 0.26 min-1 with target concentration (Tc at 2.0-µg mL-1 were administered. When the predicted propofol concentration at the effect site (Es reached half of Es value, Es was increased to previous Es + 1 µg mL-1, successively, until loss of consciousness. In rapid induction group (R, patients were induced with TCI of propofol with plasma (6.0 µg mL-1 at effect site, and waited until loss of consciousness. RESULTS: In rapid induction group, Tc for loss of consciousness was significantly lower compared to slow induction group (1.67 ± 0.76 and 2.50 ± 0.56 µg mL-1, respectively, p = 0.004. CONCLUSION: The predicted propofol concentration at the effect site for loss of consciousness is different for rapid induction and slow induction, even with the same pharmacokinetic model of propofol and the same balance constant between plasma and effect site.

  18. Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial

    DEFF Research Database (Denmark)

    Hermanides, J; Nørgaard, K; Bruttomesso, D

    2011-01-01

    To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes.......To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes....

  19. Electronic Unit Pump Diesel Engine Control Unit Design for Integrated Powertrain System

    Institute of Scientific and Technical Information of China (English)

    LIU Bo-lan; ZHAO Chang-lu; ZHANG Fu-jun; HUANG Ying

    2005-01-01

    The performance of the electronic unit pump (EUP) diesel engine is studied, it will be used in the integrated powertrain and its multi parameters are controllable. Both the theoretical analysis and experiment research are taken. A control unit for the fuel quantity and timing in crankshaft domain is designed on this basis and the engine experiment test has been done. For the constant speed camshaft driving EUP system, the fuel quantity will increase as the supply angle goes up and injection timing has no effect. The control precision can reach 1°CA. The full injection timing MAP and engine peak performance curves are made successfully.

  20. IMPROVE THE KINETIC PERFORMANCE OF THE PUMP CONTROLLED CLAMPING UNIT IN PLASTIC INJECTION MOLDING MACHINE WITH ADAPTIVE CONTROL STRATEGY

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The kinetic characteristics of the clamping unit of plastic injection molding machine that is controlled by close loop with newly developed double speed variable pump unit are investigated.Considering the wide variation of the cylinder equivalent mass caused by the transmission ratio of clamping unit and the severe instantaneous impact force acted on the cylinder during the mold closing and opening process, an adaptive control principle of parameter and structure is proposed to improve its kinetic performance. The adaptive correlation between the acceleration feedback gain and the variable mass is derived. The pressure differential feedback is introduced to improve the dynamic performance in the case of small inertia and heavy impact load. The adaptation of sum pressure to load is used to reduce the energy loss of the system. The research results are verified by the simulation and experiment. The investigation method and the conclusions are also suitable for the differential cylinder system controlled by the traditional servo pump unit.

  1. Clinical evaluation of the use of a multifunctional remotely controlled insulin pump: multicenter observational study.

    Science.gov (United States)

    Boizel, Robert; Pinget, Michel; Lachgar, Karim; Parkin, Christopher G; Grulet, Hervé; Guillon-Metz, Françoise; Weissmann, Joerg

    2014-11-01

    Current insulin pumps now feature advanced functions for calculating insulin dosages, delivering insulin and analyzing data, however, the perceived usefulness of these functions in clinical settings has not been well studied. We assessed the use and patient perceptions of an insulin delivery system (Accu-Chek® Combo, Roche Diagnostics, Mannheim, Germany) that combines an insulin pump and a handheld multifunctional blood glucose meter with integrated remote control functions. This prospective, observational, multicenter study enrolled 74 type 1 diabetes patients within 13 weeks after starting use of the pump system. At 4 to 24 weeks, investigators collected usage data from the latest 14-day period. Seventy-two patients completed the evaluation, aged 39 ± 15 years, diabetes duration 16 ± 13 years, HbA1c 8.3 ± 1.6%. At follow-up, 62 (86.1%) patients used the remote control for ≥50% of all boluses, 20 (27.8%) used the bolus advisor for ≥50% of all boluses, and 42 (58.3%) viewed at least 1 of the e-logbook reports. More than 95% of users appraised the functions as easy-to-use and useful; median scores from VAS (0 = useless to 100 = indispensable) ranged from 72 to 85. A high percentage of study patients used the system's advanced features, especially the remote control feature for bolusing. Overall, patients assessed the functions as useful and easy to use. Results support the implementation of these smart capabilities in further insulin pump developments. © 2014 Diabetes Technology Society.

  2. Intravenous lipid and heparin infusion-induced elevation in free fatty acids and triglycerides modifies circulating androgen levels in women: a randomized, controlled trial.

    Science.gov (United States)

    Mai, K; Bobbert, T; Reinecke, F; Andres, J; Maser-Gluth, C; Wudy, S A; Möhlig, M; Weickert, M O; Hartmann, M F; Schulte, H M; Diederich, S; Pfeiffer, A F H; Spranger, J

    2008-10-01

    The polycystic ovarian syndrome (PCOS) is characterized by hyperandrogenism and associated with obesity and impaired glucose metabolism. Despite the high prevalence of PCOS and the considerable clinical impact, the precise interplay between metabolism and hyperandrogenemia is not entirely clear. The objective of the study was to analyze the effects of iv lipid and heparin infusion on circulating androgen levels in healthy women. This was a randomized, controlled, crossover trial. The study was conducted at an endocrinology center. Patients included 12 healthy young women during the early follicular phase of two subsequent cycles. After an overnight fast, a 20% lipid/heparin or a saline/heparin infusion was administered in random order for 330 min. A detailed characterization of androgen metabolism was performed. Elevations in free fatty acids and triglycerides, induced by lipid/heparin infusion, elevates the levels of androstenedione, dehydroepiandrosterone (DHEA), dehydroepiandrosterone sulfate (DHEAS), testosterone, 5alpha-dihydrotestosterone, estrone, and 17beta-estradiol. Urinary excretion of DHEA, DHEAS, 5-androstene-3beta,17beta-diol, and the sum of urinary excreted DHEA and its 16-hydroxylated downstream metabolites, 16alpha-hydroxy-DHEA and 5-androstene-3beta,16alpha,17beta-triol, were reduced. The mechanism of iv lipid and heparin infusion-induced elevation of circulating androgens described here might contribute to the development of hyperandrogenism in women with PCOS and suggests that lowering of hyperlipidemia might be a potential therapeutic target in patients with PCOS to treat hyperandrogenemia.

  3. Goal-directed diuresis: A case - control study of continuous furosemide infusion in critically ill trauma patients

    Directory of Open Access Journals (Sweden)

    Daniel Dante Yeh

    2015-01-01

    Full Text Available Background: Excessive crystalloid administration is common and associated with negative outcomes in critically ill trauma patients. Continuous furosemide infusion (CFI to remove excessive fluid has not been previously described in this population. We hypothesized that a goal-directed CFI is more effective for fluid removal than intermittent bolus injection (IBI diuresis without excess incidence of hypokalemia or renal failure. Materials and Methods: CFI cases were prospectively enrolled between November 2011 and August 2012, and matched to historic IBI controls by age, gender, Injury Severity Score (ISS, and net fluid balance (NFB at diuresis initiation. Paired and unpaired analyses were performed to compare groups. The primary endpoints were net fluid balance, potassium and creatinine levels. Secondary endpoints included intensive care unit (ICU and hospital length of stay (LOS, ventilator-free days (VFD, and mortality. Results: 55 patients were included, with 19 cases and 36 matched controls. Mean age was 54 years, mean ISS was 32.7, and mean initial NFB was +7.7 L. After one day of diuresis with CFI vs. IBI, net 24 h fluid balance was negative (−0.55 L vs. +0.43 L, P = 0.026 only for the CFI group, and there was no difference in potassium and creatinine levels. Cumulative furosemide dose (59.4mg vs. 25.4mg, P < 0.001 and urine output (4.2 L vs. 2.8 L, P < 0.001 were also significantly increased with CFI vs. IBI. There were no statistically significant differences in ICU LOS, hospital LOS, VFD, or mortality. Conclusions: Compared to IBI, goal-directed diuresis by CFI is more successful in achieving net negative fluid balance in patients with fluid overload with no detrimental side effects on renal function or patient outcome.

  4. Evaluating Performance of Water Hammer Control Equipment using Hytran Software in Hasanlu Dam Pumping Station

    Directory of Open Access Journals (Sweden)

    Parisa Nazari

    2016-09-01

    Full Text Available Unsteady flows start from a steady state and end the other steady state condition. In water lines unsteady flows occur mainly due to the closure of valves, sudden pumps stops or sudden pumps starts. To prevent these losses, the major ways which can be used are pressure valves, air tanks and surge tanks. All various methods of controlling water hammer pursue a common goal, and that is to balance pressure from water hammer to adjust the pressure in an acceptable range in the network. In this paper, unsteady hydraulic flow control methods include protective measures such as the use of check valve and installation of air valves, air chambers and surge tanks are investigated and compared. And so that the1400 mm existing pipe line of Hasanlu dam pump station, can be simulated using Hytran software, and then minimum and maximum pressure due to the different choking in the throat connecting the main route was evaluated. The results presented that the use of check valve with built-in soft starter in the present case study reduces the positive and negative pressure caused by the water hammer phenomenon as possible value.

  5. A Polymer Film Dye Laser with Spatially Modulated Emission Controlled by Transversely Distributed Pumping

    Directory of Open Access Journals (Sweden)

    Zurab V. Wardosanidze

    2016-01-01

    Full Text Available Spatial modulation of laser emission controlled by the structure of excitation light field was demonstrated. A dye doped polymer film as an active medium was sandwiched between two laser mirrors forming a laser cell. The pumping was performed by an interference pattern formed with two mutually coherent beams of the second harmonic of a Q-switched Nd:YAG laser (532 nm and located in the plane of the laser cell. The laser emission was observed normally on the plane of the cell. The cross section of the obtained laser emission was modulated in intensity with an interval between maximums depending on the period of the pumping interference pattern. Thus, the emitted light field qualitatively looks like diffraction from an elementary dynamic hologram, that is, a holographic diffraction grating.

  6. Controlled release of metformin hydrochloride and repaglinide from sandwiched osmotic pump tablet.

    Science.gov (United States)

    Qin, Chao; He, Wei; Zhu, Chunli; Wu, Mengmeng; Jin, Zhu; Zhang, Qiang; Wang, Guangji; Yin, Lifang

    2014-05-15

    The marketed compound tablet of metformin hydrochloride (MH) and repaglinide (RG) exhibits perfect multidrug therapeutic effect of type 2 diabetes. However, due to the short half life of the drugs, the tablet has to be administered 2 to 3 times a day, causing inconvenience to patient and fluctuations of plasma concentration. Here, a sandwiched osmotic pump tablet was developed to deliver the two drugs simultaneously at zero-order rate, in which MH and RG were loaded in different layers separated by a push layer. The osmotic pump tablet was prepared by a combination of three tableting procedure and film coating method. The factors including type and amount of propellant, osmotic active agents, amount of porogenic agent, coating weight, orifice diameter were optimized. The pharmacokinetic study was performed in beagle dogs, and the drug concentration in plasma samples was assayed by HPLC-MS/MS method. Simultaneous, controlled release of MH and RG in the first 12 and 8h was achieved from the optimized formulation. A significantly decreased Cmax, prolonged Tmax and satisfactory bioavailability of the osmotic pump tablet were obtained, and a good in vivo-in vitro correlation of the two drugs was also established. In summary, the sandwiched osmotic pump tablet released the MH and RG simultaneously at zero-order rate, and exhibited significant sustained release effect in vivo and good in vivo-in vitro correlation. The designed controlled release system for MH and RG proposed a promising replacement for the marked compound product in the therapy of type 2 diabetes.

  7. ADRC or adaptive controller--A simulation study on artificial blood pump.

    Science.gov (United States)

    Wu, Yi; Zheng, Qing

    2015-11-01

    Active disturbance rejection control (ADRC) has gained popularity because it requires little knowledge about the system to be controlled, has the inherent disturbance rejection ability, and is easy to tune and implement in practical systems. In this paper, the authors compared the performance of an ADRC and an adaptive controller for an artificial blood pump for end-stage congestive heart failure patients using only the feedback signal of pump differential pressure. The purpose of the control system was to provide sufficient perfusion when the patients' circulation system goes through different pathological and activity variations. Because the mean arterial pressure is equal to the total peripheral flow times the total peripheral resistance, this goal was converted to an expression of making the mean aortic pressure track a reference signal. The simulation results demonstrated that the performance of the ADRC is comparable to that of the adaptive controller with the saving of modeling and computational effort and fewer design parameters: total peripheral flow and mean aortic pressure with ADRC fall within the normal physiological ranges in activity variation (rest to exercise) and in pathological variation (left ventricular strength variation), similar to those values of adaptive controller.

  8. Application of high-performance, thin-layer chromatography to quality control of antimetabolite analogue infusion bags.

    Science.gov (United States)

    Perello, L; Demirdjian, S; Dory, A; Bourget, P

    2001-01-01

    A global postproduction quality program was developed to secure chemotherapy infusion at the Gustave Roussy Institute. Despite rigorous procedures and computerized prescriptions, an analytical check was necessary to improve the quality of ready-to-use solutions of cytotoxic drugs in our Centralized Antineoplastics Reconstitution Unit. High-performance, thin-layer chromatography was selected as the analytical tool to assay 12 anticancer drugs. One of the analytical methods can separate 4 antimetabolite substances, i.e., fludarabine (FDB), cytarabine (CTB), gemcitabine (GTB), and fluorouracil (5 FU). For all infusion bags manufactured, up to 26 samples could be assayed per series using a double standard calibration (GTB and 5 FU).

  9. Study protocol. ECSSIT - Elective Caesarean Section Syntocinon Infusion Trial. A multi-centre randomised controlled trial of oxytocin (Syntocinon) 5 IU bolus and placebo infusion versus oxytocin 5 IU bolus and 40 IU infusion for the control of blood loss at elective caesarean section.

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2009-01-01

    BACKGROUND: Caesarean section is one of the most commonly performed major operations in women throughout the world. Rates are escalating, with studies from the United States of America, the United Kingdom, China and the Republic of Ireland reporting rates between 20% and 25%. Operative morbidity includes haemorrhage, anaemia, blood transfusion and in severe cases, maternal death. The value of routine oxytocics in the third stage of vaginal birth has been well established and it has been assumed that these benefits apply to caesarean delivery as well. A slow bolus dose of oxytocin is recommended following delivery of the baby at caesarean section. Some clinicians use an additional infusion of oxytocin for a further period following the procedure. Intravenous oxytocin has a very short half-life (4-10 minutes) therefore the potential advantage of an oxytocin infusion is that it maintains uterine contractility throughout the surgical procedure and immediate postpartum period, when most primary haemorrhages occur. The few trials to date addressing the optimal approach to preventing haemorrhage at caesarean section have been under-powered to evaluate clinically important outcomes. There has been no trial to date comparing the use of an intravenous slow bolus of oxytocin versus an oxytocin bolus and infusion. METHODS AND DESIGN: A multi-centre randomised controlled trial is proposed. The study will take place in five large maternity units in Ireland with collaboration between academics and clinicians in the disciplines of obstetrics and anaesthetics. It will involve 2000 women undergoing elective caesarean section after 36 weeks gestation. The main outcome measure will be major haemorrhage (blood loss >1000 ml). A study involving 2000 women will have 80% power to detect a 36% relative change in the risk of major haemorrhage with two-sided 5% alpha. DISCUSSION: It is both important and timely that we evaluate the optimal approach to the management of the third stage at

  10. Study protocol. ECSSIT - Elective Caesarean Section Syntocinon Infusion Trial. A multi-centre randomised controlled trial of oxytocin (Syntocinon) 5 IU bolus and placebo infusion versus oxytocin 5 IU bolus and 40 IU infusion for the control of blood loss at elective caesarean section.

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2012-02-01

    BACKGROUND: Caesarean section is one of the most commonly performed major operations in women throughout the world. Rates are escalating, with studies from the United States of America, the United Kingdom, China and the Republic of Ireland reporting rates between 20% and 25%. Operative morbidity includes haemorrhage, anaemia, blood transfusion and in severe cases, maternal death. The value of routine oxytocics in the third stage of vaginal birth has been well established and it has been assumed that these benefits apply to caesarean delivery as well. A slow bolus dose of oxytocin is recommended following delivery of the baby at caesarean section. Some clinicians use an additional infusion of oxytocin for a further period following the procedure. Intravenous oxytocin has a very short half-life (4-10 minutes) therefore the potential advantage of an oxytocin infusion is that it maintains uterine contractility throughout the surgical procedure and immediate postpartum period, when most primary haemorrhages occur. The few trials to date addressing the optimal approach to preventing haemorrhage at caesarean section have been under-powered to evaluate clinically important outcomes. There has been no trial to date comparing the use of an intravenous slow bolus of oxytocin versus an oxytocin bolus and infusion. METHODS AND DESIGN: A multi-centre randomised controlled trial is proposed. The study will take place in five large maternity units in Ireland with collaboration between academics and clinicians in the disciplines of obstetrics and anaesthetics. It will involve 2000 women undergoing elective caesarean section after 36 weeks gestation. The main outcome measure will be major haemorrhage (blood loss >1000 ml). A study involving 2000 women will have 80% power to detect a 36% relative change in the risk of major haemorrhage with two-sided 5% alpha. DISCUSSION: It is both important and timely that we evaluate the optimal approach to the management of the third stage at

  11. Prospective, randomized, and controlled trial on ketamine infusion during bilateral axillo-breast approach (BABA) robotic or endoscopic thyroidectomy: Effects on postoperative pain and recovery profiles

    Science.gov (United States)

    Kim, Dong-Ho; Choi, June Young; Kim, Byoung-Gook; Hwang, Jin-Young; Park, Seong-Joo; Oh, Ah-Young; Jeon, Young-Tae; Ryu, Jung-Hee

    2016-01-01

    Abstract Background: Robotic or endoscopic thyroidectomy using bilateral axillo-breast approach (BABA) is frequently performed for excellent cosmesis. However, postoperative pain is remained as concerns due to the extent tissue dissection and tension during the operation. Ketamine is a noncompetitive N-methyl-d-aspartate (NMDA) receptor antagonist that reduces acute postoperative pain. We evaluated the effects of intraoperative ketamine infusion on postoperative pain control and recovery profiles following BABA robotic or endoscopic thyroidectomy. Methods: Fifty-eight adult patients scheduled for BABA robotic or endoscopic thyroidectomy were randomized into a control group (n = 29) and ketamine group (n = 29). Following induction of anesthesia, patients in each group were infused with the same volume of saline or ketamine solution (1 mg/kg bolus, 60 μg/kg/h continuous infusion). Total intravenous anesthesia with propofol and remifentanil was used to induce and maintain anesthesia. Pain scores (101-point numerical rating scale, 0 = no pain, 100 = the worst imaginable pain), the consumption of rescue analgesics, and other postoperative adverse effects were assessed at 1, 6, 24, and 48 hours postoperatively. Results: Patients in the ketamine group reported lower pain scores than those in the control group at 6 hours (30 [30] vs 50 [30]; P = 0.017), 24 hours (20 [10] vs 30 [20]; P robotic or endoscopic thyroidectomy, with no increase in adverse events. PMID:27930531

  12. [Factors associated with glycemic control in adults with type 1 diabetes mellitus on an insulin pump].

    Science.gov (United States)

    Zhang, Yan; Xu, Wen; Ai, Heying; Lü, Jing; Zhu, Yanhua; Yang, Daizhi; Lin, Shuo; Liu, Li; Zheng, Xueying; Yan, Jinhua; Yao, Bin; Weng, Jianping

    2014-12-02

    To explore the factors associated with glycemic control in adults with type 1 diabetes mellitus (T1D) on an insulin pump. A total of 108 patients aged over 18 years and on an insulin pump therapy for >6 months were selected from 16 centers of Guangdong Type 1 diabetes Translational Medicine Study. They were classified into two groups according to the (American Diabetes Association) ADA Hemoglobin A1c target (7.0%). Those reaching the target (n = 59) were compared with those failed (n = 49) using ANOVA and Logistic regression. There were 75 females and 33 males with a median age of 32.0 (25.9-40.9) years and a median disease duration of 7.9(4.2-12.3) years. Logistic regression analysis revealed an odds ratio of 4.48(95%CI 1.53-13.15, P = 0.00) for total daily basal insulin dose within 0.2-0.3 units per kilogram, an OR of 1.31 (95%CI 1.05-1.63, P = 0.01) for self-monitoring of blood glucose (SMBG) and an OR of 3.43 (95%CI 1.18-10.01, P = 0.02) for males. Higher frequencies of SMBG and appropriate basal insulin dose are essential for adult patients with T1D on an insulin pump.

  13. Improved Automatic Filtered Power Control Pumping Method for Uniform Shortpass Band in Optical Fiber Communications

    Science.gov (United States)

    Shen, Jyi-Lai; Huang, Hau-Min; Lee, Yueh-Chien; Huang, Chia-Chih; Lin, Huang-Cuang; Lin, Chin-Yuan

    2009-01-01

    To form a low noise figure and uniform shortpass band in optical fiber communications an improved automatic filtered power control (AFPC) pumping method is proposed here. A modulated single laser signal was entered in a closed feedback loop, in which the erbium-doped fiber amplifier (EDFA) was used as a part of the AFPC loop. Owing to the constant filtered signal and the quadrature phase shift delay inside the feedback loop, an optical pass band was uniformly formed. This EDFA attains high performance with a low noise figure simultaneously. The method was successfully applied to the fabrication of practical 12.0 m length of erbium-doped fiber pumped at 980 nm wavelength and 20 dBm power. Experiments prove that the signal gain of the loop remain flat in the range of 18.2 to 22.4 dB with a worst case error of ±0.5 dB and the noise figure was reduced by 2.2 dB at optimal, which correspond to a shortpass range of 40 nm band pass from 1525 nm to 1565 nm in wavelength. Of course, it should be possible to extent the system performance to all pumping configurations for semiconductor optical amplifiers. This provides the simplest and most economical way to transmit a well-defined band of modulated laser signal and to reject all other unwanted radiation.

  14. Efficiency by means of intelligence. Control engineering increases the performance of pumping and shredders; Effizienz durch Intelligenz. Steuerungstechnik steigert die Leistung von Pump- und Zerkleinerungsanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Wenner, Carsten; Vogelsang, Hugo [Maschinenbau GmbH, Essen (Germany)

    2009-01-15

    For a long time, modern machine tools are no more applicable efficiently without electronics. However, it is expected frequently from macerators and displacement pumps that they work completely without appropriate control engineering and/or with minimal control engineering. The achievement and efficiency of these systems can be improved by the investment into modern and intelligent control engineering clearly. Under this aspect, the author of the contribution under consideration reports on the application of the macerator RotaCut 5000 in the biogas plant Duderstadt. The protection from foreign bodies and for simultaneous substrate preparation, a RotaCut 5000 is connected before the rotary pump. For both devices, an appropriate performance control unit was installed. Rotary pump and RotaCut 5000 work reliably, efficiently and attain a power demand of 10 kW. This means a saving of 1,600 kW/h per week and a saving between 10,000 and 12,000 euros per year. The entire investment amortized after some months.

  15. Controlled Study of the Effects of Continuous Intrathecal Baclofen Infusion in Non-Ambulant Children with Cerebral Palsy

    Science.gov (United States)

    Morton, Richard E.; Gray, Natalie; Vloeberghs, Michael

    2011-01-01

    Aim: To measure changes in children with severe spastic cerebral palsy (CP) after continuous intrathecal baclofen (ITB) infusion over 18 months and to compare the results with those of a comparison group awaiting treatment. Method: Thirty-eight children with severe spastic CP considered suitable for ITB were assessed when first seen, just before…

  16. [Comparative study between fast and slow induction of propofol given by target-controlled infusion: expected propofol concentration at the effect site. Randomized controlled trial].

    Science.gov (United States)

    Simoni, Ricardo Francisco; Miziara, Luiz Eduardo de Paula Gomes; Esteves, Luis Otávio; Silva, Diógenes de Oliveira; Ribeiro, Cristina Alves; Smith, Mariana Oki; Paula, Leonardo Ferreira de; Cangiani, Luis Henrique

    2015-01-01

    studies have shown that rate of propofol infusion may influence the predicted propofol concentration at the effect site (Es). The aim of this study was to evaluate the Es predicted by the Marsh pharmacokinetic model (ke0 0.26min(-1)) in loss of consciousness during fast or slow induction. the study included 28 patients randomly divided into two equal groups. In slow induction group (S), target-controlled infusion (TCI) of propofol with plasma, Marsh pharmacokinetic model (ke0 0.26min(-1)) with target concentration (Tc) at 2.0-μg.mL(-1) were administered. When the predicted propofol concentration at the effect site (Es) reached half of Es value, Es was increased to previous Es + 1μg.mL(-1), successively, until loss of consciousness. In rapid induction group (R), patients were induced with TCI of propofol with plasma (6.0μg.ml(-1)) at Es, and waited until loss of consciousness. in rapid induction group, Tc for loss of consciousness was significantly lower compared to slow induction group (1.67±0.76 and 2.50±0.56μg.mL(-1), respectively, p=0.004). the predicted propofol concentration at the effect site for loss of consciousness is different for rapid induction and slow induction, even with the same pharmacokinetic model of propofol and the same balance constant between plasma and effect site. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  17. HEAT PUMP GAS COOLER CONTROL USING CRITERION OF MINIMUM OF EXERGY LOSSSES

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2014-08-01

    Full Text Available This paper focuses on the development of the criterion of optimality of transients of the control system, based on the minimum of exergy losses in the gas cooler of carbon dioxide heat pump. It is noted that the exergy quality criterion has a clear physical meaning, as compared with the integral quadratic criterion in which the choice of the coefficients in the integrand is not justified. Mathematic model of heat exchanger is obtained using the method of solving differential equations, without going to the irrational transfer functions. The model is reduced to transfer functions of the first and second order with the delay. The continuous temperature control system of heat pump gas cooler is considered. It is shown, that one of the versions of the control system for the minimization of the proposed criterion can be a combined control system using both the principle of the negative feedback and the principle of the invariance related to a number of disturbances affecting the processes of heat transfer in the heat exchanger.

  18. Preload-based starling-like control for rotary blood pumps: numerical comparison with pulsatility control and constant speed operation.

    Directory of Open Access Journals (Sweden)

    Mahdi Mansouri

    Full Text Available In this study, we evaluate a preload-based Starling-like controller for implantable rotary blood pumps (IRBPs using left ventricular end-diastolic pressure (PLVED as the feedback variable. Simulations are conducted using a validated mathematical model. The controller emulates the response of the natural left ventricle (LV to changes in PLVED. We report the performance of the preload-based Starling-like controller in comparison with our recently designed pulsatility controller and constant speed operation. In handling the transition from a baseline state to test states, which include vigorous exercise, blood loss and a major reduction in the LV contractility (LVC, the preload controller outperformed pulsatility control and constant speed operation in all three test scenarios. In exercise, preload-control achieved an increase of 54% in mean pump flow ([Formula: see text] with minimum loading on the LV, while pulsatility control achieved only a 5% increase in flow and a decrease in mean pump speed. In a hemorrhage scenario, the preload control maintained the greatest safety margin against LV suction. PLVED for the preload controller was 4.9 mmHg, compared with 0.4 mmHg for the pulsatility controller and 0.2 mmHg for the constant speed mode. This was associated with an adequate mean arterial pressure (MAP of 84 mmHg. In transition to low LVC, [Formula: see text] for preload control remained constant at 5.22 L/min with a PLVED of 8.0 mmHg. With regards to pulsatility control, [Formula: see text] fell to the nonviable level of 2.4 L/min with an associated PLVED of 16 mmHg and a MAP of 55 mmHg. Consequently, pulsatility control was deemed inferior to constant speed mode with a PLVED of 11 mmHg and a [Formula: see text] of 5.13 L/min in low LVC scenario. We conclude that pulsatility control imposes a danger to the patient in the severely reduced LVC scenario, which can be overcome by using a preload-based Starling-like control approach.

  19. Adaptive sliding mode back-stepping pitch angle control of a variable-displacement pump controlled pitch system for wind turbines.

    Science.gov (United States)

    Yin, Xiu-xing; Lin, Yong-gang; Li, Wei; Liu, Hong-wei; Gu, Ya-jing

    2015-09-01

    A variable-displacement pump controlled pitch system is proposed to mitigate generator power and flap-wise load fluctuations for wind turbines. The pitch system mainly consists of a variable-displacement hydraulic pump, a fixed-displacement hydraulic motor and a gear set. The hydraulic motor can be accurately regulated by controlling the pump displacement and fluid flows to change the pitch angle through the gear set. The detailed mathematical representation and dynamic characteristics of the proposed pitch system are thoroughly analyzed. An adaptive sliding mode pump displacement controller and a back-stepping stroke piston controller are designed for the proposed pitch system such that the resulting pitch angle tracks its desired value regardless of external disturbances and uncertainties. The effectiveness and control efficiency of the proposed pitch system and controllers have been verified by using realistic dataset of a 750 kW research wind turbine.

  20. Control strategy for multi-pump emulsion power station in coal mine face

    Institute of Scientific and Technical Information of China (English)

    LI Wen-ying; WEI Jin-hong

    2011-01-01

    Shearer and hydraulic support are matching equipments.To increase the operating speed of the shearer,the following speed of hydraulic support must be increased.This means increasing the volume of flow from emulsion power station.Analyzing the operating characteristics of hydraulic supports,the number of simultaneously operating supports is obtained by means of pressure parameter and time history at a certain time,which is a theory base for development of control system to multi-pump emulsion power station.

  1. Project risk control of underground engineering geological disaster in pumped-storage power station

    Institute of Scientific and Technical Information of China (English)

    Luo Shaoji

    2014-01-01

    This paper introduced the construction of the pumped-storage power station (PSPS). In the excava- tion of underground power house, the principle of excavation in thin layer and support in time with real time monitoring are adopted. The excavation blasting parameters are adjusted timely. Through these, the excavation quality can be guaranteed, the surrounding rock can be prevented from being damaged and the deformation of power house side wall can be controlled. Five security defense lines have been adopted to solve anti-seepage and drainage in the major underground projects.

  2. Project risk control of underground engineering geological disaster in pumped-storage power station

    Institute of Scientific and Technical Information of China (English)

    Luo Shaoji

    2014-01-01

    This paper introduced the construction of the pumped-storage power station (PSPS). In the excava-tion of underground power house,the principle of excavation in thin layer and support in time with real time monitoring are adopted. The excavation blasting parameters are adjusted timely. Through these,the excavation quality can be guaranteed,the surrounding rock can be prevented from being damaged and the deformation of power house side wall can be controlled. Five security defense lines have been adopted to solve anti-seepage and drainage in the major underground projects.

  3. Design and analysis of optically pumped semiconductor VECSEL with ANECz optical control layer

    Institute of Scientific and Technical Information of China (English)

    Yuqi Zhou; Dapeng Zhao; Yajuan Li; Qingxin Yang

    2008-01-01

    Through the reversible isomerization of trans-cis-trans under the linear polarization light, the molecules of azo materials have the same tropism which is vertical to the polarization of light. This means that azo materials have photo-induced birefringence which is related to optical power and polarization angle of the light. Based on the photo-induced birefringence of azo materials, we design a new type of optically pumped semiconductor vertical external cavity surface emitting laser (OPS-VECSEL) which can control the polarization and frequency of the ejection laser. The functional molecules of azo materials are [3-azo- (4'nitro)]-(9-ethyl)-carbazole (ANECz).

  4. Analysis and Control of Axial Thrust in Centrifugal Pump by Use of J-Groove

    OpenAIRE

    Abe, Heishiro; Matsumoto, Kazunari; Kurokawa, Junichi; Matsui, Jun; Choi, Young-Do

    2006-01-01

    In order to control and balance axial thrust of turbo machine, many types of balancing devices are used but most of them are complicated and sometimes cause troubles. In this study, a very simple device of using shallow grooves mounted on a casing wall, known as "J-Groove", is proposed and studied experimentally and theoretically. The result shows that 70% of axial thrust in an industry, 4-stage centrifugal pump can be reduced at the best efficiency point. Moreover, the analytical method of "...

  5. Effective background infusion rate of ropivacaine 0.2% for patient-controlled interscalene brachial plexus analgesia after rotator cuff repair surgery

    Institute of Scientific and Technical Information of China (English)

    Wei Yue; Li Min; Rong Yulan; Guo Xiangyang

    2014-01-01

    Background Continuous interscalene nerve block (CISB) is considered to be the most effective method for postoperative analgesia after shoulder surgery with prolonged severe pain.This study was performed to evaluate the minimum effective background infusion rate and the effective background infusion rate of ropivacaine 0.2% for CISB after arthroscopic rotator cuff repair surgery in 95% of patients.Methods Patients scheduled for arthroscopic rotator cuff repair surgery under general anesthesia at Peking University Third Hospital were prospectively enrolled from December 2011 to May 2012.Preoperatively,an interscalene catheter (ISC) was placed under the guidance of ultrasound and nerve stimulation in each patient.Consecutively,30 patients with successful nerve block were included.A continuous infusion of ropivacaine 0.2% with a 5 ml patient-controlled bolus available hourly was started at postoperative anesthesia care unit (PACU) after completion of surgery.The initial background infusion rate was 6 ml/h,which was subsequently varied for each consecutive patient according to the analgesic effects of the previous one.The minimum effective background rate was determined using the Dixon and Massey up-and-down method.The effective background rate in 95% of patients was calculated using isotonic analysis.Results The minimum effective background rate based on the Dixon and Massey up-and-down method was 2.8 ml/h (95% CI,2.3-3.3 ml/h).The effective background rate in 95% of patients calculated with the isotonic regression analysis was 4.4 ml/h (95% CI,3.8-6.5 ml/h).Conclusion The effective background rate for patient-controlled interscalene brachial plexus analgesia after shoulder surgery in 50% and 95% of the patients was 2.8 and 4.4 ml/h,respectively.

  6. Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial.

    Science.gov (United States)

    Haidar, Ahmad; Legault, Laurent; Messier, Virginie; Mitre, Tina Maria; Leroux, Catherine; Rabasa-Lhoret, Rémi

    2015-01-01

    The artificial pancreas is an emerging technology for the treatment of type 1 diabetes and two configurations have been proposed: single-hormone (insulin alone) and dual-hormone (insulin and glucagon). We aimed to delineate the usefulness of glucagon in the artificial pancreas system. We did a randomised crossover trial of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy (continuous subcutaneous insulin infusion) in participants aged 12 years or older with type 1 diabetes. Participants were assigned in a 1:1:1:1:1:1 ratio with blocked randomisation to the three interventions and attended a research facility for three 24-h study visits. During visits when the patient used the single-hormone artificial pancreas, insulin was delivered based on glucose sensor readings and a predictive dosing algorithm. During dual-hormone artificial pancreas visits, glucagon was also delivered during low or falling glucose. During conventional insulin pump therapy visits, patients received continuous subcutaneous insulin infusion. The study was not masked. The primary outcome was the time for which plasma glucose concentrations were in the target range (4·0-10·0 mmol/L for 2 h postprandially and 4·0-8·0 mmol/L otherwise). Hypoglycaemic events were defined as plasma glucose concentration of less than 3·3 mmol/L with symptoms or less than 3·0 mmol/L irrespective of symptoms. Analysis was by modified intention to treat, in which we included data for all patients who completed at least two visits. A p value of less than 0·0167 (0·05/3) was regarded as significant. This trial is registered with ClinicalTrials.gov, number NCT01754337. The mean proportion of time spent in the plasma glucose target range over 24 h was 62% (SD 18), 63% (18), and 51% (19) with single-hormone artificial pancreas, dual-hormone artificial pancreas, and conventional insulin pump therapy, respectively. The mean difference in time spent in the target

  7. Low-dose ketamine infusion for labor analgesia: A double-blind, randomized, placebo controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Sam Joel

    2014-01-01

    Full Text Available Background: Most primary and secondary level hospitals in developing countries provide inadequate labor analgesia due to various medical, technical and economic reasons. This clinical trial was an effort to study the efficacy, safety and feasibility of intravenous (IV ketamine to provide labor analgesia. Materials and Methods: A total of 70 parturients were consented and randomly assigned to receive either IV ketamine or 0.9% saline. A loading dose of ketamine (0.2 mg/kg was followed-by an infusion (0.2 mg/kg/h until the delivery of the neonate. Similar volume of saline was infused in the placebo-group. Intramuscular meperidine was the rescue analgesic in both groups. The pain score, hemodynamic parameters of mother and fetus and the anticipated side-effects of ketamine were observed for. The newborn was assessed by the Neonatologist. Results: The pain score showed a decreasing trend in the ketamine group and after the 1 st h more than 60% of women in the ketamine group had pain relief, which was statistically significant. There was no significant clinical change in the maternal hemodynamics and fetal heart rate. However, 17 (48.5% of them had transient light headedness in the ketamine group. All the neonates were breast fed and the umbilical cord blood pH was between 7.1 and 7.2. The overall satisfaction was significantly high in the intervention group (P = 0.028. Conclusion: A low-dose ketamine infusion (loading dose of 0.2 mg/kg delivered over 30 min, followed-by an infusion at 0.2 mg/kg/h could provide acceptable analgesia during labor and delivery.

  8. Fabrication of Slippery Lubricant-Infused Porous Surface with High Underwater Transparency for the Control of Marine Biofouling.

    Science.gov (United States)

    Wang, Peng; Zhang, Dun; Sun, Shimei; Li, Tianping; Sun, Yan

    2017-01-11

    Marine optical instruments are bearing serious biofouling problem, which affects the accuracy of data collected. To solve the biofouling problem of marine optical instruments, a novel instance of slippery lubricant-infused porous surface (SLIPS) with high underwater-transparency was designed over glass substrate via infusing lubricant into its porous microstructure fabricated with hydrothermal method. The advantage of SLIPS as antibiofouling strategy to marine optical instruments was proven by comparing its underwater optical and antibiofouling performances with three kinds of samples (hydrophilic glass sample, textured hydrophilic glass sample, and superhydrophobic glass sample). The modification of SLIPS enhances the underwater-transparency of glass sample within the wavelength of 500-800 nm, for the infusion of lubricant with lower refractive index than glass substrate. In contrast with hydrophilic surface, textured hydrophilic surface and superhydrophobic surface, SLIPS can significantly inhibit bacterial and algal settlements, thereby maintaining high underwater-transparency in both dynamic and static seawater. The inhibition of bacterial and algal settlements over SLIPS results from its liquid-like property. The contact angle hysteresis of water over SLIPS increases with immersion time in seawater under different conditions (static, dynamic, and vibration conditions). Both dynamic and vibration conditions accelerate the failure of SLIPS exposed in seawater. This research provides valuable information for solving biofouling problem of marine optical instruments with SLIPS.

  9. [Research on magnetic coupling centrifugal blood pump control based on a self-tuning fuzzy PI algorithm].

    Science.gov (United States)

    Yang, Lei; Yang, Ming; Xu, Zihao; Zhuang, Xiaoqi; Wang, Wei; Zhang, Haibo; Han, Lu; Xu, Liang

    2014-10-01

    The purpose of this paper is to report the research and design of control system of magnetic coupling centrifugal blood pump in our laboratory, and to briefly describe the structure of the magnetic coupling centrifugal blood pump and principles of the body circulation model. The performance of blood pump is not only related to materials and structure, but also depends on the control algorithm. We studied the algorithm about motor current double-loop control for brushless DC motor. In order to make the algorithm adjust parameter change in different situations, we used the self-tuning fuzzy PI control algorithm and gave the details about how to design fuzzy rules. We mainly used Matlab Simulink to simulate the motor control system to test the performance of algorithm, and briefly introduced how to implement these algorithms in hardware system. Finally, by building the platform and conducting experiments, we proved that self-tuning fuzzy PI control algorithm could greatly improve both dynamic and static performance of blood pump and make the motor speed and the blood pump flow stable and adjustable.

  10. Controlled delivery of carvedilol nanosuspension from osmotic pump capsule: in vitro and in vivo evaluation.

    Science.gov (United States)

    Liu, Dandan; Yu, Shihui; Zhu, Zhihong; Lyu, Chunyang; Bai, Chunping; Ge, Huiqi; Yang, Xinggang; Pan, Weisan

    2014-11-20

    This study intended to develop a novel controlled delivery osmotic pump capsule of carvedilol nanosuspension. The capsule is assembled using a semi-permeable capsule shell with contents including nanosuspension drying powder, mannitol and Plasdone S-630. The physical characteristics of semi-permeable capsule walls were compared among different coating solutions under different temperature. The composition of the coating solution and drying temperature appeared to be important for the formation of the shells. Carvedilol nanosuspension was prepared by precipitation-ultrasonication technique and was further lyophilized. Response surface methodology was used to investigate the influence of factors on the responses. The optimized formulation displayed complete drug delivery and zero-order release rate. The TEM and particle size analysis indicated that the morphology of the resultant nanoparticle in the capsule was spherical shaped with a mean size of 252±19 nm. The in vivo test in beagle dogs demonstrated that the relative bioavailability of the novel system was 203.5% in comparison to that of the marketed preparation. The capsule successfully controlled the release of carvedilol and the fluctuation of plasma concentration was minimized. The system is a promising strategy to improve the oral bioavailability for poorly soluble drugs and preparing it into elementary osmotic pump conveniently.

  11. Design and evaluation of osmotic pump-based controlled release system of Ambroxol Hydrochloride.

    Science.gov (United States)

    Cheng, Xiongkai; Sun, Min; Gao, Yan; Cao, Fengliang; Zhai, Guangxi

    2011-08-01

    The purpose of the present study was to design and evaluate an osmotic pump-based drug delivery system for controlling the release of Ambroxol Hydrochloride (Amb). Citric acid, lactose and polyethylene glycol 6000 (PEG 6000) were employed as osmotic agents. Surelease EC containing polyethylene glycol 400 (PEG 400) controlling the membrane porosity was used as semi-permeable membrane. The formulation of tablet core was optimized by orthogonal design and evaluated by weighted mark method. The influences of the amount of PEG 400 and membrane thickness on Amb release were investigated. The optimal osmotic pump tablet (OPT) was evaluated in different release media and at different stirring rates. The major release power confirmed was osmotic pressure. The release of Amb from OPT was verified at a rate of approximately zero-order, and cumulative release percentage at 12?h was 92.6%. The relative bioavailability of Amb OPT in rabbits relative to the commercial sustained capsule was 109.6%. Our results showed that Amb OPT could be a practical preparation with a good prospect.

  12. Design of low cost smart infusion device

    Science.gov (United States)

    Saputra, Yohanes David; Purnamaningsih, Retno Wigajatri

    2015-01-01

    We propose design of a smart infusion device suitable for public hospitals in Indonesia. The device comprised of LED, photodiode and DC motor to measure and control the infusion rate, using the principle of LED beam absorption. The infusion rate was identified by using microcontroller and displayed through computer unit. Experiment results for different flow rate level and concentration of Dextrose showed that the device is able to detect, measure, and control the infusion droplets flow rate by the average error rate of 1.0081%.

  13. Sodium pump α2 subunits control myogenic tone and blood pressure in mice

    Science.gov (United States)

    Zhang, Jin; Lee, Moo Yeol; Cavalli, Maurizio; Chen, Ling; Berra-Romani, Roberto; Balke, C William; Bianchi, Giuseppe; Ferrari, Patrizia; Hamlyn, John M; Iwamoto, Takahiro; Lingrel, Jerry B; Matteson, Donald R; Wier, W Gil; Blaustein, Mordecai P

    2005-01-01

    A key question in hypertension is: How is long-term blood pressure controlled? A clue is that chronic salt retention elevates an endogenous ouabain-like compound (EOLC) and induces salt-dependent hypertension mediated by Na+/Ca2+ exchange (NCX). The precise mechanism, however, is unresolved. Here we study blood pressure and isolated small arteries of mice with reduced expression of Na+ pump α1 (α1+/−) or α2 (α2+/−) catalytic subunits. Both low-dose ouabain (1–100 nm; inhibits only α2) and high-dose ouabain (≥1 μm; inhibits α1) elevate myocyte Ca2+ and constrict arteries from α1+/−, as well as α2+/− and wild-type mice. Nevertheless, only mice with reduced α2 Na+ pump activity (α2+/−), and not α1 (α1+/−), have elevated blood pressure. Also, isolated, pressurized arteries from α2+/−, but not α1+/−, have increased myogenic tone. Ouabain antagonists (PST 2238 and canrenone) and NCX blockers (SEA0400 and KB-R7943) normalize myogenic tone in ouabain-treated arteries. Only the NCX blockers normalize the elevated myogenic tone in α2+/− arteries because this tone is ouabain independent. All four agents are known to lower blood pressure in salt-dependent and ouabain-induced hypertension. Thus, chronically reduced α2 activity (α2+/− or chronic ouabain) apparently regulates myogenic tone and long-term blood pressure whereas reduced α1 activity (α1+/−) plays no persistent role: the in vivo changes in blood pressure reflect the in vitro changes in myogenic tone. Accordingly, in salt-dependent hypertension, EOLC probably increases vascular resistance and blood pressure by reducing α2 Na+ pump activity and promoting Ca2+ entry via NCX in myocytes. PMID:16166162

  14. Anesthesia induction effect and RAAS system activity of low-dose midazolam combined with target-controlled propofol infusion under BIS monitoring

    Institute of Scientific and Technical Information of China (English)

    Wen-Shan Lu; Cong-Hui Wang; Chan-Ying Xie; Bo Lyu; Shi-Min Wu

    2016-01-01

    Objective:To study the anesthesia induction effect and RAAS system activity of low-dose midazolam combined with target-controlled propofol infusion under BIS monitoring. Methods:A total of 40 patients undergoing selective general anesthesia surgery in our hospital between April 2012 and December 2015 were selected and randomly divided into control group (group C) and low-dose midazolam group (group M), plasma concentration EC50 of target-controlled propofol infusion was assessed, and the plasma concentrations of NO, NO2-, NO3-, XOD, PRA, ANG-II and ALD were determined before and after induction.Results:Propofol EC50 of group M was significantly lower than that of group C; before and after anesthesia induction, mean arterial pressure, arterial partial pressure of oxygen, arterial partial pressure of carbon dioxide and central venous pressure of group M were not significantly different from those of group C; after anesthesia induction, NO, NO2-, NO3- and XOD content in plasma of group C were significantly lower than those before anesthesia induction while PRA, ANG-II and ALD concentration were significantly higher than those before anesthesia induction, and NO, NO2-, NO3-, XOD, PRA, ANG-II and ALD content in plasma of group M were not significantly different from those before anesthesia induction; NO, NO2-, NO3-and XOD content in plasma of group M after anesthesia induction were significantly higher than those of group C while PRA, ANG-II and ALD concentration were significantly lower than those of group C. Conclusions:Low-dose midazolam combined with target-controlled propofol infusion under BIS monitoring is with exact anesthetic effect and can reduce the dosage of propofol and inhibit the activation of RAAS system.

  15. Report of a 7 year case-control study of continuous intraperitoneal insulin infusion and subcutaneous insulin therapy among patients with poorly controlled type 1 diabetes mellitus : Favourable effects on hypoglycaemic episodes

    NARCIS (Netherlands)

    van Dijk, P. R.; Logtenberg, S. J. J.; Groenier, K. H.; Gans, R. O. B.; Bilo, H. J. G.; Kleefstra, N.

    2014-01-01

    Aims: Continuous intraperitoneal insulin infusion (CIPII) is a last-resort treatment option for patients with type 1 diabetes mellitus (T1DM) who fail to reach adequate glycaemic control with subcutaneous (SC) insulin therapy. Aim was to compare the long-term effects of CIPII and SC insulin therapy

  16. Report of a 7 year case-control study of continuous intraperitoneal insulin infusion and subcutaneous insulin therapy among patients with poorly controlled type 1 diabetes mellitus : Favourable effects on hypoglycaemic episodes

    NARCIS (Netherlands)

    van Dijk, P. R.; Logtenberg, S. J. J.; Groenier, K. H.; Gans, R. O. B.; Bilo, H. J. G.; Kleefstra, N.

    2014-01-01

    Aims: Continuous intraperitoneal insulin infusion (CIPII) is a last-resort treatment option for patients with type 1 diabetes mellitus (T1DM) who fail to reach adequate glycaemic control with subcutaneous (SC) insulin therapy. Aim was to compare the long-term effects of CIPII and SC insulin therapy

  17. Anestesia venosa total em regime de infusão alvo-controlada: uma análise evolutiva Anestesia venosa total en régimen de infusión objeto controlada: un análisis evolutivo Total intravenous anesthesia as a target-controlled infusion: an evolutive analysis

    Directory of Open Access Journals (Sweden)

    Fernando Squeff Nora

    2008-04-01

    ón objeto controlada (IOC. El primer modelo farmacocinético descrito para uso en IOC, fue descrito por Schwilden en 1981. Quedó demostrado a partir de entonces, que era posible mantener la concentración plasmática deseada de un fármaco utilizando bomba de infusión por computador. CONTENIDO: Este artigo quiso dejar sentadas las bases teóricas de la IOC, presentar una propuesta de desarrollo de un vocabulario común en IOC todavía no publicado en Brasil y hacer un análisis crítico de los aspectos actuales de la IOC en el mundo y en Brasil. CONCLUSIONES: La llegada de nuevas bombas de infusión dotadas de los modelos farmacocinéticos del remifentanil, sufentanil y propofol inaugura otro capítulo de la AVT y coloca a Brasil a tono con la tendencia mundial en IOC. Esos sistemas facilitarán la IOC de hipnóticos y opioides concomitantemente. La conclusión más importante, sin embargo, se refiere a la economía en la medida en que los fármacos utilizados en esas bombas no quedarán restrictos a solamente una empresa farmacéutica, como por ejemplo lo que ocurrió con el propofol. Hoy ya disponemos de equipos para la utilización de propofol y opioides en IOC, que aceptan cualquier presentación farmacéutica con la ventaja de poder alterar la concentración del fármaco en la jeringuilla de acuerdo con la dilución que se desee.BACKGROUND AND DOBJECTIVES: Total intravenous anesthesia (TIVA has seen several developments since it was first used. Since the synthesis of the first intravenous anesthetics, with the introduction of barbiturates (1921 and thiopental (1934, TIVA has evolved until the development of TIVA with target-controlled infusion pumps (TCI. The first pharmacokinetic model for the use of TCI was described by Schwilden in 1981. From that moment on, it was demonstrated that it is possible to maintain the desired plasma concentration of a drug using an infusion pump managed by a computer. CONTENTS: The objective of this report was to describe the

  18. Clinical research of impulse GnRH infusion treatment to a patient with central secondary amenorrhea

    Institute of Scientific and Technical Information of China (English)

    孙首悦

    2014-01-01

    Objective To apply continuous subcutaneous pulse infusion of gonadotropin-releasing hormone(GnRH)to treat patients with central secondary amenorrhea,and to observe the induction of spontaneous ovulation and natural fertilization.Methods Using micro-pulse infusion pumps with each 90-minute infusion of LHRH 10μg daily,the serum LH,FSH,estrogen,and progesterone lev-

  19. GUI Of Control System On The Level Of Oil Tank By Two Pumps Using V. Basic

    Directory of Open Access Journals (Sweden)

    Qusay Jalil

    2015-08-01

    Full Text Available Abstract Science is developing applications in all fields medical industrial agricultural military .... etc. private computer applications and at the moment has become easier development tasks through a computer which controls the systems through the so-called graphical user interface GUI where it is through the graphical interface to control the whole system in terms of operating appeared maintenance and other this is not only but rather can handle the graphical interface by any person who is not a specialist in the field of control of any It simplifies dealing with the system by the designer person.This paper represents a simplification of the work of control is full of a large volume of fuel tank system as in factories through the two pumps and valves discharge consists of control system of two parts 1- Software 2- Hardware for Soft is the part of the compiler is responsible for receiving data processed and giving orders to the hardware for the purpose of implementation.This is done simulations of the system through the graphical user interface GUI designed under the working environment V.BASIC by a specialist engineer to be controlled by someone less experienced in the field of control

  20. Field evaluation of advanced controls for the retrofit of packaged air conditioners and heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

    2015-09-01

    This paper documents the magnitude of energy savings achievable in the field by retrofitting existing packaged rooftop units (RTUs) with advanced control strategies not ordinarily used for RTUs. A total of 66 RTUs on 8 different buildings were retrofitted with a commercially available advanced controller for improving RTU operational efficiency. The controller features enhanced air-side economizer control, multi-speed fan control, and demand controlled ventilation. Of the 66 RTUs, 18 are packaged heat pumps and the rest are packaged air conditioners with gas heat. The eight buildings cover four building types and four climate conditions. Based on the data collected for about a whole year, the advanced controller reduced the normalized annual RTU energy consumption between 22% and 90%, with an average of 57% for all RTUs. The average fractional savings uncertainty was 12% at 95% confidence level. Normalized annual electricity savings were in the range between 0.47 kWh/h (kWh per hour of RTU operation) and 7.21 kWh/h, with an average of 2.39 kWh/h. RTUs greater than 53 kW and runtime greater than 14 hours per day had payback periods less than 3 years even at $0.05/kWh.

  1. Risk Analyses of Charging Pump Control Improvements for Alternative RCP Seal Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun-Chan [Korea Hydro and Nuclear Power Co. Ltd. Daejeon (Korea, Republic of)

    2015-10-15

    There are two events that significantly affect the plant risk during a TLOCCW event. One is an event in which the seal assembly of a reactor coolant pump (RCP) fails due to heating stress from the loss of cooling water; the other is an event in which the operators fail to conduct alternative cooling for the RCP seal during the accident. KHNP reviewed the replacement of the RCP seal with a qualified shutdown seal in order to remove the risk due to RCP seal failure during a TLOCCW. As an optional measure, a design improvement in the alternative cooling method for the RCP seal is being considered. This analysis presents the alternative RCP seal cooling improvement and its safety effect. K2 is a nuclear power plant with a Westinghouse design, and it has a relatively high CDF during TLOCCW events because it has a different CCW system design and difficulty in preparing alternative cooling water sources. This analysis confirmed that an operator action providing cold water to the RWST as RCP seal injection water during a TLOCCW event is very important in K2. The control circuit improvement plan for the auxiliary charging pump was established in order to reduce the failure probability of this operator action. This analysis modeled the improvement as a fault tree and evaluated the resulting CDF change. The consequence demonstrated that the RCP seal injection failure probability was reduced by 89%, and the CDF decreased by 28%.

  2. Method of infusion extraction

    Science.gov (United States)

    Chang-Diaz, Franklin R. (Inventor)

    1989-01-01

    Apparatus and method of removing desirable constituents from an infusible material by infusion extraction, where a piston operating in a first chamber draws a solvent into the first chamber where it may be heated, and then moves the heated solvent into a second chamber containing the infusible material, and where infusion extraction takes place. The piston then moves the solvent containing the extract through a filter into the first chamber, leaving the extraction residue in the second chamber.

  3. PRINCIPLE TO CLOSED LOOP CONTROL DIFFERENTIAL CYLINDER WITH DOUBLE SPEED VARIABLE PUMPS AND SINGLE LOOP CONTROL SIGNAL

    Institute of Scientific and Technical Information of China (English)

    Quan Long; Neubert T; Helduser S

    2004-01-01

    To control the position of differential cylinder closed loop without using any throttle elements, a new idea that two speed variable pumps are used to compensate the non-symmetric flow of differential cylinder is carried out.According to the leaking property of the system, a speed offset principle is also proposed to eliminate the cavitation and tension caused by the leakage and condensation of oil, which makes the system be in the same state as a valve controlled circuit.This principle is explained theoretically and experimentally.Further the relationship that the pressures in cylinder chambers change with load and leakage, and the relationship between biasing speed and pre-load pressures in cylinder chambers are established.The research has proved that the new system has similar technique features as those of controlled with servo valves, but due to the elimination of all the throttle lose the efficiency of system can be improved greatly.

  4. A randomized controlled trial of foley catheter, extra-amniotic saline infusion and prostaglandin e2 suppository for labor induction.

    Directory of Open Access Journals (Sweden)

    Mandana Mansour Ghanaie

    2013-06-01

    Full Text Available The aim of this study is to further compare the efficacy of PGE2 suppository, the intracervical foley catheter and extra-amniotic saline infusion in nulliparous women referred for labor induction.Totally 368 nulliparous women with a Bishop score ≤ 4 with singleton gestation, vertex presentation and intact membrane referred for labor induction were randomly assigned to 3 groups; Foley catheter alone, Extra-amniotic saline infusion (EASI and PGE2 suppository. All women received concurrent dilute oxytocine infusion. The change in the Bishop Score, labor progress, various labor endpoints and outcomes of labor were assessed.From 363 women studied after exclusion of 5, 119 were assigned to EASI, 121 to Foley and 118 to PGE2. Patients' demographics did not differ significantly between three groups nor did indication for induction (P = 0.0001. The EASI group had a significant improvement in Bishop Score 6 hours after induction. The mean time to active phase was 357±135min for EASI,457±178 for Foley and 609±238 min for PGE2 group respectively (P < 0.05.rate of spontaneous rupture of membranes was higher in the EASI group (P = 0.0001 and the mean time from the start of induction up to spontaneous rupture of membranes in the EASI group was shorter than other group(P < 0.05. The mean time to vaginal delivery was 14.8±6.1 in EASI group,11.4±4.8 in Foley and 18.9±6.4 in PGE2 group(P < 0.05.there were no differences in Apgar scores, mean neonatal birth weight and neonatal morbidity.Our study showed that pre-induction cervical ripening by EASI with concurrent oxytocin is better than Foley and PGE2 in Bishop score and various labor end point and outcomes.

  5. MODELING OF THE HEAT PUMP STATION CONTROLABLE LOOP OF AN INTERMEDIATE HEAT-TRANSFER AGENT (Part II

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2011-08-01

    Full Text Available It is studied the model of the heat pump station controllable loop of an intermediate heat-transfer agent for the use in wineries. There are demonstrated transients after the disturbing action of the temperature on the input of cooling jacket of the fermentation stirred tank. There are compared different control laws of the object.

  6. Leg edema from intrathecal opiate infusions.

    Science.gov (United States)

    Aldrete, J A; Couto da Silva JM

    2000-01-01

    Despite the increasing popularity of intrathecal infusions to treat patients with long-term non-cancer-related pain, this therapy is not without serious side-effects. Five out of 23 patients who had intrathecal infusions of opiates for longer than 24 months developed leg and feet edema. As predisposing factors, cardiovascular disease, deep venous thrombosis, peripheral vascular disease, and venous stasis of the lower extremities were considered. Every patient who developed pedal and leg edema after the implantation of an infusion pump was also found to have leg edema and venous stasis prior to the time when the pump was inserted. This complication was severe enough to limit their physical activity, and to produce lymphedema, ulcerations and hyperpigmentation of the skin. Reduction of the edema occurred when the dose of the opiate was decreased, and in two cases in which the infusion was discontinued, there was almost complete resolution of the syndrome. It appears that the pre-existence of pedal edema and of venous stasis is a relative contraindication to the long-term intrathecal infusion of opiates in patients with chronic non-cancer pain. Copyright 2000 European Federation of Chapters of the International Association for the Study of Pain.

  7. Autonomous BDFIG-wind generator with torque and pitch control for maximum efficiency in a water pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Camocardi, P. [LEICI, Universidad Nacional de La Plata, 1 y 47, CC 91 (1900) La Plata (Argentina); CONICET (Argentina); Battaiotto, P. [LEICI, Universidad Nacional de La Plata, 1 y 47, CC 91 (1900) La Plata (Argentina); Mantz, R. [LEICI, Universidad Nacional de La Plata, 1 y 47, CC 91 (1900) La Plata (Argentina); Comision de Investigaciones Cientificas de la Provincia de Buenos Aires (Argentina)

    2010-06-15

    This paper presents and analyzes the operation strategy for an autonomous wind energy conversion system oriented to water pumping. It consists of a wind turbine with a Brushless Doubly-Fed Induction Generator (BDFIG), electrically coupled with a squirrel cage induction machine moving a centrifugal type water pump. Because of no brushes and slip rings, the BDFIG is suitable for autonomous systems, which often work in hard conditions. Additionally, the power flow on the BDFIG principal stator could be driven from a fractional power converter connected on the auxiliary stator winding. This Turbine-BDFIG and Motor-Pump configuration provides a high robustness and reliability, reducing the operational and maintenance costs. The operation strategy proposes, for wind speeds smaller than the rated, to maximize the volume of water pumped based on the optimization of the wind energy capture. To do that, a sliding mode control tracks the optimal turbine torque by means of a torque control. Meanwhile, for wind speeds greater than the rated, a pitch control keeps the water pump within the safe operation area by adjusting the speed and power of the turbine in their rated values. To assess and corroborate the proposed strategy, simulations with different wind profiles are made. (author)

  8. A review on controlled porosity osmotic pump tablets and its evaluation

    Directory of Open Access Journals (Sweden)

    Chinmaya Keshari Sahoo

    2015-12-01

    Full Text Available Conventional drug delivery system provides an immediate release of drug which does not control the release of the drug and does not maintain effective concentration at target site for a longer period of time. Hence to avoid the shortcomings there is development of various controlled drug delivery systems. Among these osmotic drug delivery system (ODDS utilizes the principle of osmotic pressure and delivers drug dose in an optimized manner to maintain drug concentration within the therapeutic window and minimizes toxic effects. ODDS releases drug at a controlled rate that is independent of the pH and thermodynamics of dissolution medium. The release of drug from ODDS follows zero order kinetics. The release of drug from osmotic system depends upon various formulation factors such as solubility, osmotic pressure of the core components, size of the delivery orifice and nature of the rate controlling membrane. Controlled porosity osmotic pump (CPOP contains drug, osmogens, excipients in core and a coating of semipermeable membrane with water soluble additives. In CPOP water soluble additives dissolve after coming in contact with water, resulting in an in situ formation of a microporous membrane. The present study gives an idea about osmosis, CPOP, components of CPOP and its evaluation.

  9. Feedback Control and Dynamic Behaviour of Z-Source Converter Fed Separately Excited DC Motor and Centrifugal Pump Set

    Directory of Open Access Journals (Sweden)

    Saswati Swapna Dash

    2014-07-01

    Full Text Available This paper presents an overall study of Feedback Control of Z-Source Converter Fed Separately excited DC motor with centrifugal Pump Set. Z-source converter can be used for both voltage buck and boost mode using LC impedance network. In this paper the dynamic modeling of Z-source with motor load and centrifugal pump set is carried out with new findings. The compensators for speed feedback loop are designed by taking average state space analysis and small signal model of the system. The feedback loop is designed by classical control methods. The experiment is done in MATLAB work environment and the result is verified by Simulation.

  10. Direct cost of connecting, maintaining and disconnecting patient-controlled analgesia pump

    Directory of Open Access Journals (Sweden)

    Áquila Lopes Gouvêa

    2014-02-01

    Full Text Available Quantitative research that aimed to identify the mean total cost (MTC of connecting, maintaining and disconnecting patient-controlled analgesia pump (PCA in the management of pain. The non-probabilistic sample corresponded to the observation of 81 procedures in 17 units of the Central Institute of the Clinics Hospital, Faculty of Medicine, University of Sao Paulo. We calculated the MTC multiplying by the time spent by nurses at a unit cost of direct labor, adding the cost of materials and medications/solutions. The MTC of connecting was R$ 107.91; maintenance R$ 110.55 and disconnecting R$ 4.94. The results found will subsidize discussions about the need to transfer money from the Unified Health System to hospitals units that perform this technique of analgesic therapy and it will contribute to the cost management aimed at making efficient and effective decision-making in the allocation of available resources.

  11. Patient-Controlled Transdermal Fentanyl Versus Intravenous Morphine Pump After Spine Surgery.

    Science.gov (United States)

    Lindley, Emily M; Milligan, Kenneth; Farmer, Ryan; Burger, Evalina L; Patel, Vikas V

    2015-09-01

    Patient-controlled analgesia (PCA) is regularly used to manage pain following major surgery. The fentanyl hydrochloride iontophoretic transdermal system (ITS) was developed to overcome some of the limitations of intravenous (IV) PCA. The small, self-adhesive, needle-free disposable system is applied to the skin on the upper arm or chest and is controlled by patients clicking a button on the device. The authors identified patients who were underwent spinal surgery from 2 prior multicenter, randomized studies and analyzed their data. Of the 1296 patients in the original trials, 170 underwent spine surgery procedures: 90 were randomized to the fentanyl ITS (40 mcg/activation) and 80 to IV PCA morphine (1 mg/dose). More patients treated with the fentanyl ITS rated their method of pain control as "excellent" across all time points, but differences did not reach statistical significance. However, investigators' ratings of "excellent" satisfaction with study treatment were significantly higher for the fentanyl ITS. Discontinuation rates and overall adverse event rates were similar between groups. The only significant difference was that patients treated with the fentanyl ITS had a higher rate of application site reactions than infusion site reactions in the IV PCA morphine group; the reactions were typically mild-to-moderate erythema that resolved shortly after removal of the fentanyl ITS device and did not require further treatment. Ratings of satisfaction with pain control method were consistently higher for the fentanyl ITS than the IV PCA morphine. The 2 groups had a similar safety profile. These results suggest that the fentanyl ITS appears to be a safe, efficacious alternative to IV PCA in spine surgery patients.

  12. A computer-controlled syringe driver for use during anaesthesia. A modification of the Graseby MS16A.

    Science.gov (United States)

    Cohen, A T

    1986-06-01

    The requirements of a drug infusion device for use in theatre are discussed. A modification of the Graseby MS16A syringe pump and an interface circuit permitting its remote control by microcomputer are described. The pump is controlled via a standard computer interface (RS232) which makes it a unique and powerful research tool. Aspects of safety are considered.

  13. The Combination of Micro Diaphragm Pumps and Flow Sensors for Single Stroke Based Liquid Flow Control.

    Science.gov (United States)

    Jenke, Christoph; Pallejà Rubio, Jaume; Kibler, Sebastian; Häfner, Johannes; Richter, Martin; Kutter, Christoph

    2017-04-03

    With the combination of micropumps and flow sensors, highly accurate and secure closed-loop controlled micro dosing systems for liquids are possible. Implementing a single stroke based control mode with piezoelectrically driven micro diaphragm pumps can provide a solution for dosing of volumes down to nanoliters or variable average flow rates in the range of nL/min to μL/min. However, sensor technologies feature a yet undetermined accuracy for measuring highly pulsatile micropump flow. Two miniaturizable in-line sensor types providing electrical readout-differential pressure based flow sensors and thermal calorimetric flow sensors-are evaluated for their suitability of combining them with mircopumps. Single stroke based calibration of the sensors was carried out with a new method, comparing displacement volumes and sensor flow volumes. Limitations of accuracy and performance for single stroke based flow control are described. Results showed that besides particle robustness of sensors, controlling resistive and capacitive damping are key aspects for setting up reproducible and reliable liquid dosing systems. Depending on the required average flow or defined volume, dosing systems with an accuracy of better than 5% for the differential pressure based sensor and better than 6.5% for the thermal calorimeter were achieved.

  14. Non-invasive estimation and control of inlet pressure in an implantable rotary blood pump for heart failure patients.

    Science.gov (United States)

    Alomari, A H; Savkin, A V; Ayre, P J; Lim, E; Mason, D G; Salamonsen, R F; Fraser, J F; Lovell, N H

    2011-08-01

    We propose a dynamical model for mean inlet pressure estimation in an implantable rotary blood pump during the diastolic period. Non-invasive measurements of pump impeller rotational speed (ω), motor power (P), and pulse width modulation signal acquired from the pump controller were used as inputs to the model. The model was validated over a wide range of speed ramp studies, including (i) healthy (C1), variations in (ii) heart contractility (C2); (iii) afterload (C2, C3, C4), and (iv) preload (C5, C6, C7). Linear regression analysis between estimated and extracted mean inlet pressure obtained from in vivo animal data (greyhound dogs, N = 3) resulted in a highly significant correlation coefficients (R(2) = 0.957, 0.961, 0.958, 0.963, 0.940, 0.946, and 0.959) and mean absolute errors of (e = 1.604, 2.688, 3.667, 3.990, 2.791, 3.215, and 3.225 mmHg) during C1, C2, C3, C4, C5, C6, and C7, respectively. The proposed model was also used to design a controller to regulate mean diastolic pump inlet pressure using non-invasively measured ω and P. In the presence of model uncertainty, the controller was able to track and settle to the desired input within a finite number of sampling periods and minimal error (0.92 mmHg). The model developed herein will play a crucial role in developing a robust control system of the pump that detects and thus avoids undesired pumping states by regulating the inlet pressure within a predefined physiologically realistic limit.

  15. A Peristaltic Pump Integrated on a 100% Glass Microchip Using Computer Controlled Piezoelectric Actuators

    Directory of Open Access Journals (Sweden)

    Yo Tanaka

    2014-05-01

    Full Text Available Lab-on-a-chip technology is promising for the miniaturization of chemistry, biochemistry, and/or biology researchers looking to exploit the advantages of a microspace. To manipulate fluid on a microchip, on-chip pumps are indispensable. To date, there have been several types of on-chip pumps including pneumatic, electroactive, and magnetically driven. However these pumps introduce polymers, metals, and/or silicon to the microchip, and these materials have several disadvantages, including chemical or physical instability, or an inherent optical detection limit. To overcome/avoid these issues, glass has been one of the most commonly utilized materials for the production of multi-purpose integrated chemical systems. However, glass is very rigid, and it is difficult to incorporate pumps onto glass microchips. This paper reports the use of a very flexible, ultra-thin glass sheet (minimum thickness of a few micrometers to realize a pump installed on an entirely glass-based microchip. The pump is a peristaltic-type, composed of four serial valves sealing a cavity with two penetrate holes using ultra-thin glass sheet. By this pump, an on-chip circulating flow was demonstrated by directly observing fluid flow, visualized via polystyrene tracking particles. The flow rate was proportional to the pumping frequency, with a maximum flow rate of approximately 0.80 μL/min. This on-chip pump could likely be utilized in a wide range of applications which require the stability of a glass microchip.

  16. AUTOMATIC CONTROL SYSTEM OF THE DIFFERENCE BETWEEN DISCHARGE AND SUCTION PRESSURES OF THE HEAT PUMP STATION COMPRESSOR

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2009-04-01

    Full Text Available Possibility of realization is shown and the control system of a difference of pressure between an exit and an input of the compressor of the heat pump on carbon dioxide working at variable thermal load, and discharge and suction pressures by means of two control valves connected in series is developed. On an example a flow coefficient calculation procedure of control valves is shown.

  17. A New Optimum Frequency Controller of Hybrid Pumping System: Bond Graph Modeling-Simulation and Practice with ARDUINO Board

    OpenAIRE

    MEZGHANI Dhafer; OTHMANI Hichem; SASSI Fares; Mami, Abdelkader; Dauphin-Tanguy, Geneviève

    2017-01-01

    The strategy of rural development in Tunisia needs to include as one of its priorities: the control of water. In seeking solutions for the energy control dedicated to pumping, it seems interesting to know the benefits of a new technique based on the complementarities of two renewable energy sources such as solar and wind power. The climate’s dependence requires a complex modelling and more optimization methods for controlling of hybrid system. Moreover, in recent years, technological progress...

  18. Integration of Variable Speed Pumped Hydro Storage in Automatic Generation Control Systems

    Science.gov (United States)

    Fulgêncio, N.; Moreira, C.; Silva, B.

    2017-04-01

    Pumped storage power (PSP) plants are expected to be an important player in modern electrical power systems when dealing with increasing shares of new renewable energies (NRE) such as solar or wind power. The massive penetration of NRE and consequent replacement of conventional synchronous units will significantly affect the controllability of the system. In order to evaluate the capability of variable speed PSP plants participation in the frequency restoration reserve (FRR) provision, taking into account the expected performance in terms of improved ramp response capability, a comparison with conventional hydro units is presented. In order to address this issue, a three area test network was considered, as well as the corresponding automatic generation control (AGC) systems, being responsible for re-dispatching the generation units to re-establish power interchange between areas as well as the system nominal frequency. The main issue under analysis in this paper is related to the benefits of the fast response of variable speed PSP with respect to its capability of providing fast power balancing in a control area.

  19. A Neural Network Based MPPT Technique Controller for Photovoltaic Pumping System

    Directory of Open Access Journals (Sweden)

    Mohammed Yaichi

    2014-03-01

    Full Text Available The article proposes a novel method using the artificial neural network (ANN for the improvement of the performances of a photovoltaic system composed of a photovoltaic (PV array, an inverter, a motor asynchronous and a centrifugal pump. For this type of system, different optimization strategies have been proposed to improve the over of the PV system efficiency, i.e. the PV generator is forced to operate at its maximum power point “MPPT”, generally, by the insertion of DC/DC boost converter between the photovoltaic array and the inverter. In this work we propose an approach, where optimization is realized without need adding a DC/DC converter to the chain, using field-oriented control through the monitoring of the voltage-fed inverter frequency. The motor is also ensured in all insolation conditions. A multilayer feed forward perception type NN is proposed for MPPT control, and the back-propagation algorithm is used for training. The performances of the drive with ANN-based MPPT are excellent. The maximum power point (MPP can be easily obtained to frequency-controlled drive.

  20. Low-Cost Control System Built Upon Consumer-Based Electronics For Supervisory Control Of A Gas-Operated Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Wetherington Jr, G Randall [ORNL; Vineyard, Edward Allan [ORNL; Mahderekal, Isaac [ORNL; Abu-Heiba, Ahmad [ORNL

    2017-06-01

    A preliminary evaluation of the performance of a consumer-based control system was conducted by the Oak Ridge National Laboratory (ORNL) and Southwest Gas as part of a cooperative research and development agreement (CRADA) authorized by the Department of Energy (DOE) (Mahderekal et al. (2013). The goal of the research was to evaluate the low-cost approach as a solution for implementing a supervisory control system for a residential gas-operated heat pump. The design incorporated two consumer-based micro-controllers; the Arduino Mega-2650 and the BeagleBone (white). Ten five-ton heat pump systems were designed, fabricated, and operationally tested in the Las Vega NV region. A robust data set was produced that allowed detailed assessment of the reliability and the operational perfromance of the newly developed control system. Experiences gained from the test provided important points of improvement for subsequent evolution of the heat pump technology.

  1. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  2. Analog Fixed Maximum Power Point Control for a PWM Step-downConverter for Water Pumping Installations

    DEFF Research Database (Denmark)

    Beltran, H.; Perez, E.; Chen, Zhe

    2009-01-01

    This paper describes a Fixed Maximum Power Point analog control used in a step-down Pulse Width Modulated power converter. The DC/DC converter drives a DC motor used in small water pumping installations, without any electric storage device. The power supply is provided by PV panels working around...

  3. Pressure management of water distribution systems via the remote real-time control of variable speed pumps

    CSIR Research Space (South Africa)

    Page, Philip R

    2017-08-01

    Full Text Available Low and constant pressure can be maintained throughout a water distribution system by setting the pressure at remote consumer locations and using the pressure to control the speed of a variable speed pump (VSP). The prospect of incorporating...

  4. Means-End based Functional Modeling for Intelligent Control: Modeling and Experiments with an Industrial Heat Pump System

    DEFF Research Database (Denmark)

    Saleem, Arshad

    2007-01-01

    The purpose of this paper is to present a Multilevel Flow Model (MFM) of an industrial heat pump system and its use for diagnostic reasoning. MFM is functional modeling language supporting an explicit means-ends intelligent control strategy for large industrial process plants. The model is used...

  5. Means-End based Functional Modeling for Intelligent Control: Modeling and Experiments with an Industrial Heat Pump System

    DEFF Research Database (Denmark)

    Saleem, Arshad

    2007-01-01

    The purpose of this paper is to present a Multilevel Flow Model (MFM) of an industrial heat pump system and its use for diagnostic reasoning. MFM is functional modeling language supporting an explicit means-ends intelligent control strategy for large industrial process plants. The model is used...

  6. Impact of insulin pump therapy on long-term glycemic control in a pediatric Spanish cohort.

    Science.gov (United States)

    Colino, Esmeralda; Martín-Frías, María; Yelmo, Rosa; Álvarez, M Ángeles; Roldán, Belén; Barrio, Raquel

    2016-03-01

    To evaluate the efficacy and safety of Continuous Subcutaneous Insulin Infusion (CSII) in a pediatric cohort and to determine if the ISPAD/IDF/ADA criteria for good metabolic control are achieved during long periods of time. Retrospective longitudinal study including ninety patients [10.5 (6.5-13.9) years of age, 58% males]. Age at debut, type 1 diabetes mellitus duration, pubertal stage, HbA1c, insulin dose, mean number of glycemic controls, number of basal rates, % basal/total insulin, severe hypoglycemia and diabetic ketoacidosis events were analyzed. Subgroup analysis based on age and pubertal stage was performed. HbA1c decreased from 6.9% [52 mmol/mol] to 6.7% [50 mmol/mol] after one year of CSII. Afterwards, it remained less than 7% during the follow-up period (median 3.5 ± 1.8 years (range 1-8). Prior to CSII, 76% of the subjects met ISPAD/ADA criteria. One year after initiating CSII, 96% of children had HbA1cinsulin dose decreased from 0.89 to 0.73 UI/kg/day (pinsulin changed significantly (47 to 42% (p<0.05)). Number of fractions of the basal rate increased from 5.6 ± 1.8 at one year of CSII to 6.7 ± 2.1 five years later. Incidence of severe hypoglycemic events decreased from 19 to 6.9 episodes/100 patient-year. Only 2 episodes of diabetic ketoacidosis occurred. CSII allows reaching ISPAD/IDF/ADA goals safely during an extended follow-up period in a diabetic pediatric cohort. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Real-time Control of sewer pumps by using ControlNEXT to smooth inflow at Waste Water Treatment Plant Garmerwolde

    Science.gov (United States)

    van Heeringen, Klaas-Jan; van Nooijen, Ronald; Kooij, Kees; Postma, Bokke

    2016-04-01

    The Garmerwolde waste water treatment plant (WWTP) in the Groningen area of the Netherlands, receives waste water from a large area. That waste water is collected from many sewer systems and transported to the WWTP through pressurized pipes. The supply of waste water to the WWTP is relatively low and very irregular during dry-weather conditions, resulting in a random pattern of flows. This irregularity is the effect of the local control of the pumps, where the pumps are individually operated as an on/off control based on the water levels in the connected sewer system. The influent may change from zero to high values in a few minutes. The treatment processes at the WWTP are negatively influenced by this irregularity, which ends in high costs for energy and use of chemicals. The ControlNEXT central control system is used to control the 5 largest pump stations, such that the total inflow at the WWTP becomes much smoother. This results in a reduction of operational costs of about 10%. The control algorithm determines whether the actual condition is dry or wet, based on real-time radar precipitation images and the rainfall forecast product HiRLAM. All actual data is also collected and validated, like water levels, pump operations and pump availability. This data management is done using Delft-FEWS. If the situation is identified as "wet", the sewer systems are emptied as far as possible to create maximum storage. If the situation is "dry" (and of course there is a dead band between dry and wet), the pumps are operated such that the total inflow into the WWTP is smoothed. This is done with a Greedy algorithm, developed by Delft University of Technology. The algorithm makes a plan for the next 24 hours (as the daily inflow has a typical daily pattern) and generally stores some water volume in the sewer systems during the day to be able to continue operations during the night. The pumps are controlled with a time step of 5 minutes, where ControlNEXT manages the

  8. Effect of Quantum Interference from Incoherent Pumping Field and Spontaneous Emission on Controlling the Optical Bistability and Multi-Stability

    Institute of Scientific and Technical Information of China (English)

    H.R.Hamedi; Ali Sari; M.Sahrai; S.H.Asadpour

    2013-01-01

    Optical bistability (OB) and optical multi-stability (OM) of a four-level A-type atomic system with two fold lower levels inside a unidirectional ring cavity is investigated.The effect of quantum interference arising from spontaneous emission and incoherent pumping on OB and OM is discussed.It is found that the threshold of OB and OM can be controlled by quantum interference mechanisms.In addition intensity of coupling field and the rate of an incoherent pumping field on behavior of OB and OM are then discussed.

  9. Pressure Pump Power Control in the Primary Circuit of the Heat Exchange System

    Directory of Open Access Journals (Sweden)

    Shilin Aleksandr

    2017-01-01

    Full Text Available In this paper we consider the problem of speed in hot water systems where highly efficient plate heat exchanger is used. Especially marked the problem which is connected with long transition drive of constant speed exceeding the time of the heat exchanger accumulative tank emptying more than twice. As a regulating element in the heat exchange system there was proposed to use asynchronous electric drive of pressure pump in the primary circuit of the heat exchanger. For correct use of such electric drive we solved the problem of control object mathematical model synthesis, which has non-linear properties, in particular, the transfer coefficient of the circuit can vary in more than 6 times. At the same time there was revealed the dependence of the transfer coefficient on the motor speed, which must be considered in the controller synthesis. In conclusion we suggested the solutions of regulators synthesis tasks with customizable settings for speed and switchable structure between relay λ and PI regulators.

  10. SEMICONDUCTOR INTEGRATED CIRCUITS Short locking time and low jitter phase-locked loop based on slope charge pump control

    Science.gov (United States)

    Zhongjie, Guo; Youbao, Liu; Longsheng, Wu; Xihu, Wang; Wei, Tang

    2010-10-01

    A novel structure of a phase-locked loop (PLL) characterized by a short locking time and low jitter is presented, which is realized by generating a linear slope charge pump current dependent on monitoring the output of the phase frequency detector (PFD) to implement adaptive bandwidth control. This improved PLL is created by utilizing a fast start-up circuit and a slope current control on a conventional charge pump PLL. First, the fast start-up circuit is enabled to achieve fast pre-charging to the loop filter. Then, when the output pulse of the PFD is larger than a minimum value, the charge pump current is increased linearly by the slope current control to ensure a shorter locking time and a lower jitter. Additionally, temperature variation is attenuated with the temperature compensation in the charge pump current design. The proposed PLL has been fabricated in a kind of DSP chip based on a 0.35 μm CMOS process. Comparing the characteristics with the classical PLL, the proposed PLL shows that it can reduce the locking time by 60% with a low peak-to-peak jitter of 0.3% at a wide operation temperature range.

  11. Study protocol for a double blind, randomised, placebo-controlled trial of continuous subpectoral local anaesthetic infusion for pain and shoulder function following mastectomy: SUB-pectoral Local anaesthetic Infusion following MastEctomy (SUBLIME) study

    Science.gov (United States)

    Langford, R; Brown, I; Vickery, J; Mitchell, K; Pritchard, C; Creanor, S

    2014-01-01

    Introduction Over 16 000 mastectomies are performed in England and Wales annually. Acute postoperative pain and nausea are common. The most frequently occurring long-term complications are chronic pain (up to 50%) and reduced shoulder function (reported at 35%). Regional techniques that improve acute postoperative pain relief may reduce the incidence of these complications. This study assesses the effectiveness of a 24-hour continuous local anaesthetic in the subpectoral plane in improving postoperative pain and quality of life in patients undergoing mastectomy. Methods and analysis This is a randomised, double blind, placebo-controlled, two-centre, parallel group trial in women undergoing mastectomy with or without axillary involvement. One hundred and sixty participants will be randomised in a 1:1 ratio to receive either 0.25% levobupivacaine or 0.9% saline by subpectoral infusion postoperatively for 24 h. All participants will be provided with an intravenous morphine patient-controlled analgesia (PCA) system. Participants will be followed-up for 24 h in hospital and at approximately 14 days and 6 months postoperatively. Joint primary outcome measures are total morphine consumption and total pain score (captured via patient-recorded visual analogue scale (VAS) 4 hourly) during the first 24 h postoperatively. Primary statistical analysis of total pain is based on the area under the curve of pain versus time graph. Secondary outcomes include PCA attempts in first 24 h; VAS pain scores and shoulder function by goniometry at 24 h, 14 days (approximately) and 6 months; Verbal Rating Scale pain scores in first 24 h; Brief Pain Inventory and Oxford Shoulder Score at 6 months; duration of hospital stay; incidence of postoperative nausea and vomiting; cost-effectiveness. Ethics and dissemination The study is approved by the South West England Research Ethics Committee (12/SW/0149). Results will be published in a peer-reviewed journal and presented

  12. Postoperative pain control by preventive intercostal nerve block under direct vision followed by catheter-based infusion of local analgesics in rib cartilage harvest for auricular reconstruction in children with microtia: A randomized controlled trial.

    Science.gov (United States)

    Woo, Kyong-Je; Kang, Bo Young; Min, Jeong Jin; Park, Jin-Woo; Kim, Ara; Oh, Kap Sung

    2016-09-01

    Children with microtia complain of severe postoperative pain during early postoperative days after rib cartilage harvest for auricular reconstruction. The purpose of this study was to evaluate the effects of preventive donor site wound analgesia by intercostal nerve block (ICNB) and catheter-based infusion of local analgesics on postoperative pain after rib cartilage graft for auricular reconstruction in children with microtia. In this prospective randomized study, 66 children underwent postoperative pain control using either preventive ICNB followed by catheter-based infusion (33 patients, study group) or intravenous (IV) analgesia alone (33 patients, control group). ICNB was performed under direct vision by the surgeon by injecting 0.5% bupivacaine into each of the three intercostal spaces before perichondrial dissection. Catheters were placed in three subchondral spaces before wound closure, and 0.5% bupivacaine was infused every 12 h for 48 h postoperatively. Pain degrees were recorded every 4 h during the first 48 postoperative hours using a visual analogue scale. The study group showed significantly lower mean pain scores of the chest at rest (3.7 vs. 5.1, p = 0.001), the chest during coughing (4.3 vs. 5.8, p = 0.006), and the ear (3.0 vs. 4.1, p = 0.001) than the control group. The amount of use of rescue IV ketorolac was smaller in the study group (p = 0.026) than in the control group. No side effects related to the intervention were noted. Preventive ICNB followed by catheter-based infusion is effective and safe in postoperative pain relief in rib cartilage graft for auricular reconstruction. (The clinical trial registration number: WHO ICTRP, apps.who.int/trialsearch (KCT0001668)). Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Effects of target-controlled infusion of high-dose naloxone on pain and hyperalgesia in a human thermal injury model: a study protocol

    Science.gov (United States)

    Springborg, Anders D.; Jensen, Elisabeth K.; Taylor, Bradley K.; Werner, Mads U.

    2016-01-01

    Abstract Mu-opioid-receptor antagonists have been extensively studied in experimental research as pharmacological tools uncovering mechanisms of pain modulation by the endogenous opioid system. In rodents, administration of high doses of mu-opioid-receptor antagonists after the resolution of an inflammatory injury has demonstrated reinstatement of nociceptive hypersensitivity indicating unmasking of latent sensitization. In a recent human study, pain hypersensitivity assessed as secondary hyperalgesia area (SHA), was reinstated 7 days after a mild thermal injury, in 4 out of 12 subjects after a naloxone infusion. The aims of the present study are first, to replicate our previous findings in a larger-sized study; second, to examine if high sensitizers (subjects presenting with large SHA after a thermal injury) develop a higher degree of hypersensitivity after naloxone challenge than low sensitizers (subjects presenting with restricted SHA after a thermal injury); and third to examine a dose–response relationship between 3 stable naloxone concentrations controlled by target-controlled infusion, and the unmasking of latent sensitization. Healthy participants (n = 80) underwent a screening day (day 0) with induction of a thermal skin injury (47°C, 420 seconds, 12.5 cm2). Assessment of SHA was performed 1 and 2 hours after the injury. Using an enriched design, only participants belonging to the upper quartile of SHA (Q4, high sensitizers; n = 20) and the lower quartile of SHA (Q1, low sensitizers; n = 20) continued the study, comprising 4 consecutive days—days 1 to 4. Thermal skin injuries were repeated on day 1 and day 3, whereas day 2 and day 4 (7 days after day 1 and day 3, respectively) were target-controlled infusion days in which the subjects were randomly allocated to receive either naloxone (3.25 mg/kg, 4 mg/mL) or placebo (normal saline) intravenous. The primary outcome was SHA assessed by weighted-pin instrument (128 mN) 0, 1, 2

  14. Comparison of the effectiveness of dexmedetomidine versus propofol target-controlled infusion for sedation during coblation-assisted upper airway procedure

    Institute of Scientific and Technical Information of China (English)

    MA Xiao-xu; FANG Xiang-ming; HOU Tie-ning

    2012-01-01

    Background Sedation for the coblation-assisted upper airway procedure has lacked easy modulation between appropriate pain control and airway protection.This study aimed to compare the effectiveness of dexmedetomidine versus target controlled propofol infusion in providing sedation during a coblation-assisted upper airway procedure.Methods In a prospective,randomized trial,60 adult patients with obstructive sleep apnea syndrome due to undergoing a coblation-assisted upper airway procedure were enrolled and randomly allocated to receive dexmedetomidine,1.0 μg/kg over 10 minutes and maintain dosage 0.7 μg·kg-1·h-1 (n=30) or propofol target controlled infusion (n=30).Satisfaction with the analgesia and tolerance of the procedure by the patient,as assessed by a visual analogue scale,were evaluated as primary outcomes.Cardiopulmonary parameters and some side effects were monitored and recorded.Results Both groups of 30 patients had comparable demographics and initial parameters.Patients in the propofol group reported more pain (P <0.05),tolerated the procedure less well (P <0.05),and were less satisfied with the different stages of procedure (P <0.05 or P <0.01).Changes in mean arterial pressure and heart rate were more dramatic in the propofol group (P<0.05).The dexmedetomidine group experienced fewer airway events and less respiratory depression than did the propofol group.Conclusion Dexmedetomidine in conjunction with local anesthesia offered better analgesia and conscious sedation for a coblation-assisted upper airway procedure as well as less airway obstruction,apnea and greater haemodynamic stability.

  15. Combining pump-and-treat and physical barriers for contaminant plume control.

    Science.gov (United States)

    Bayer, Peter; Finkel, Michael; Teutsch, Georg

    2004-01-01

    A detailed analysis is presented of the hydraulic efficiency of plume management alternatives that combine a conventional pump-and-treat system with vertical, physical hydraulic barriers such as slurry walls or sheet piles. Various design settings are examined for their potential to reduce the pumping rate needed to obtain a complete capture of a given contaminated area. Using established modeling techniques for flow and transport, those barrier configurations (specified by location, shape, and length) that yield a maximum reduction of the pumping rate are identified assuming homogeneous aquifer conditions. Selected configurations are further analyzed concerning their hydraulic performance under heterogeneous aquifer conditions by means of a stochastic approach (Monte Carlo simulations) with aquifer transmissivity as a random space function. The results show that physical barriers are an appropriate means to decrease expected (mean) pumping rates, as well as the variance of the corresponding pumping rate distribution at any given degree of heterogeneity. The methodology presented can be transferred easily to other aquifer scenarios, provided some basic premises are fulfilled, and may serve as a basis for reducing the pumping rate in existing pump-and-treat systems.

  16. Control of transient gain absorption via tunneling and incoherent pumping in triple quantum dots

    Science.gov (United States)

    Tian, Si-Cong; Zhang, Xiao-Jun; Wan, Ren-Gang; Wang, Li-Jie; Shu, Shi-Li; Wang, Tao; Lu, Ze-Feng; Sun, Fang-Yuan; Tong, Cun-Zhu

    2017-01-01

    The transient gain-absorption properties of the probe field in vertical triple quantum dots assisted by double tunneling and incoherent pumping are investigated. With a proper intensity value and detuning of the second tunneling, the transient gain in triple quantum dots with incoherent pumping can be completely eliminated. In addition, the incoherent pumping affects both the amplitude of the transient absorption and the steady-state value. The dependence of transient behaviors on other parameters, such as the radiative decay rate and the pure dephasing decay rate of the quantum dots, is also discussed. The scheme may have important applications in quantum information networks and communication.

  17. Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation

    Science.gov (United States)

    Gregory, Shaun D.; Salamonsen, Robert F.; Lovell, Nigel H.; Stevens, Michael C.; Pauls, Jo P.; Akmeliawati, Rini; Lim, Einly

    2017-01-01

    Due to a shortage of donor hearts, rotary left ventricular assist devices (LVADs) are used to provide mechanical circulatory support. To address the preload insensitivity of the constant speed controller (CSC) used in conventional LVADs, we developed a preload-based Starling-like controller (SLC). The SLC emulates the Starling law of the heart to maintain mean pump flow (QP¯) with respect to mean left ventricular end diastolic pressure (PLVEDm) as the feedback signal. The SLC and CSC were compared using a mock circulation loop to assess their capacity to increase cardiac output during mild exercise while avoiding ventricular suction (marked by a negative PLVEDm) and maintaining circulatory stability during blood loss and severe reductions in left ventricular contractility (LVC). The root mean squared hemodynamic deviation (RMSHD) metric was used to assess the clinical acceptability of each controller based on pre-defined hemodynamic limits. We also compared the in-silico results from our previously published paper with our in-vitro outcomes. In the exercise simulation, the SLC increased QP¯ by 37%, compared to only 17% with the CSC. During blood loss, the SLC maintained a better safety margin against left ventricular suction with PLVEDm of 2.7 mmHg compared to -0.1 mmHg for CSC. A transition to reduced LVC resulted in decreased mean arterial pressure (MAP) and QP¯ with CSC, whilst the SLC maintained MAP and QP¯. The results were associated with a much lower RMSHD value with SLC (70.3%) compared to CSC (225.5%), demonstrating improved capacity of the SLC to compensate for the varying cardiac demand during profound circulatory changes. In-vitro and in-silico results demonstrated similar trends to the simulated changes in patient state however the magnitude of hemodynamic changes were different, thus justifying the progression to in-vitro evaluation. PMID:28212401

  18. Formulation and evaluation of controlled porosity osmotic pump for oral delivery of ketorolac.

    Science.gov (United States)

    Dasankoppa, Fatima Sanjeri; Ningangowdar, Mahesh; Sholapur, Hasanpasha

    2012-12-01

    The osmotic drug delivery systems suitable for oral administration typically consist of a compressed tablet core that is coated with a semipermeable membrane that has an orifice drilled on it by means of a laser beam or mechanical drill. Ketorolac is a nonsteroidal agent with powerful analgesic. Oral bioavailability of ketorolac was reported to be 90% with very low hepatic first-pass elimination; the biological half-life of 4-6 hours requires frequent administration to maintain the therapeutic effect. The aim of the current study was to design a controlled porosity osmotic pump (CPOP)based drug delivery system for controlled release of an NSAID agent, ketorolac tromethamine, which is expected to improve patient compliance due to reduced frequency; it also eliminates the need for complicated and expensive laser drilling and maintain continuous therapeutic concentration. The CPOP was designed containing pore-forming water-soluble additives in the coating membrane, which after coming in contact with water, dissolve, resulting in an in situ formation of a micro porous structure. The effect of different formulation variables, namely level of pore former (PVP), plasticizer (dibutyl phthalate) in the membrane, and membrane weight gain were studied. Drug release was inversely proportional to the membrane weight but directly related to the initial concentration of pore former (PVP) in the membrane. Drug release was independent of pH and agitational intensity, but dependent on the osmotic pressure of the release media. Based on the in vitro dissolution profile, formulation F3C1 (containing 0.5 g PVP and 1 g dibutyl phthalate in coating membrane) exhibited Peppas kinetic with Fickian diffusion-controlled release mechanism with a drug release of 93.67% in 12 hours and hence it was selected as optimized formulation. SEM studies showed the formation of pores in the membrane. The formulations were stable after 3 months of accelerated stability studies. CPOP was designed for

  19. Direct effects of locally administered lipopolysaccharide on glucose, lipid, and protein metabolism in the placebo-controlled, bilaterally infused human leg

    DEFF Research Database (Denmark)

    Buhl, Mads; Bosnjak, Ermina; Vendelbo, Mikkel H

    2013-01-01

    discrimination between direct and indirect effects impossible. Objective: We sought to define the direct, placebo-controlled effects of LPS on insulin resistance and protein and lipid metabolism in the infused human leg without systemic interference from cytokines and stress hormones. Design......Context: Accumulating evidence suggests that chronic exposure to lipopolysaccharide (LPS, endotoxin) maycreate a constant low-grade inflammation, leading to insulin resistance and diabetes. All previous human studies assessing the metabolic actions of LPS have used systemic administration, making...... release in the perfused human leg without detectable effects on amino acid metabolism. Conclusions: These data strongly suggest that the primary metabolic effect of LPS is increased lipolysis and muscle insulin resistance, which, together with secondary insulin resistance, caused by systemic cytokine...

  20. SIMULATION IN THERMAL DESIGN FOR ELECTRONIC CONTROL UNIT OF ELECTRONIC UNIT PUMP

    Institute of Scientific and Technical Information of China (English)

    XU Quankui; ZHU Keqing; ZHUO Bin; MAO Xiaojian; WANG Junxi

    2008-01-01

    The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation, the thermal design of ECU for electronic unit pump (EUP) fuel system is applied. The power dissipation model of each power component in the ECU is created and simulated. According to the analyses of simulation results, the factors which affect the power dissipation of components are analyzed. Then the ways for reducing the power dissipation of power components are carried out. The power dissipation of power components at different engine state is calculated and analyzed. The maximal power dissipation of each power component in all possible engine state is also carried out based on these simulations. A cooling system is designed based on these studies. The tests show that the maximum total power dissipation of ECU drops from 43.2 W to 33.84 W after these simulations and optimizations. These applications of simulations in thermal design of ECU can greatly increase the quality of the design, save the design cost and shorten design time

  1. Formulation development and evaluation of controlled porosity osmotic pump delivery system for oral delivery of atenolol

    Directory of Open Access Journals (Sweden)

    Garvendra S Rathore

    2012-01-01

    Full Text Available In the present study, we developed and evaluated the controlled porosity osmotic pump (CPOP based drug delivery system of sparingly water soluble drug atenolol (ATL. We selected target release profile and optimized different variables to help us achieve this. Formulation variables, such as, the levels of solubility enhancer (0-15% w/w of drug, ratio of the drug to the osmogents, coat thickness of the semipermeable membrane (SPM and level of pore former (0-20% w/w of polymer were found to effect the drug release from the developed formulations. Cellulose acetate (CA 398-10 was used as the semipermeable membrane containing polyethylene glycol 400 as the Cplasticizer. ATL release was directly proportional to the level of the solubility enhancer, osmotic pressure generated by osmotic agent and level of pore former; however, was inversely proportional to the coat thickness of SPM. Drug release from developed formulations was independent of the pH and agitation intensities of release media. Burst strength of the exhausted shells decreased with increase in the level of pore former. The optimized formulations were subjected to stability studies as per International Conference on Harmonisation (ICH guidelines, and formulations were found to be stable after 3 months study. Steady-state plasma levels of drug were predicted by the method of superposition.

  2. Predicting the effectiveness of insulin pump therapy on glycemic control in clinical practice: a retrospective study of patients with type 1 diabetes from 10 outpatient diabetes clinics in Sweden over 5 years.

    Science.gov (United States)

    Clements, Mark; Matuleviciene, Viktorija; Attvall, Stig; Ekelund, Magnus; Pivodic, Aldina; Dahlqvist, Sofia; Fahlén, Martin; Haraldsson, Börje; Lind, Marcus

    2015-01-01

    Multicenter long-term studies of predictors for the effectiveness of continuous subcutaneous insulin infusion (CSII) in clinical practice are lacking. We hypothesized that there are substantially greater reductions in hemoglobin A1c (HbA1c) in patients with poor glycemic control and that other predictors may also exist. We used data from 10 outpatient diabetic clinics in Sweden and studied CSII treatment over 5 years. Patients with HbA1c values available ≤ 6 months before starting CSII and at 5 years were included (n = 272, 82% of CSII patients) along with 2,437 contemporaneous controls on multiple daily insulin injections (MDI). Baseline variables evaluated were age, sex, diabetes duration, insulin dose, body mass index (BMI), HbA1c at baseline, and outpatient clinical care unit. At 5 years, significantly greater reductions in HbA1c by CSII compared with MDI were found for patients with higher baseline HbA1c (P = 0.032) and lower baseline BMI (P = 0.013). For baseline HbA1c levels of 7.0%, 8.0%, and 9.0% and a BMI of 25 kg/m(2), the reduction in HbA1c level by CSII was 0.08% (difference not significant), 0.16% (95% confidence interval, 0.03-0.29%), and 0.25% (95% confidence interval, 0.11-0.39%), respectively. Corresponding analyses for the change in HbA1c level from start to 1 and 2 years revealed a significant interaction of insulin pump therapy only with baseline HbA1c levels (P pump therapy, but effects remain relatively modest even for patients with poor control. Factors predicting successful insulin pump use need further study.

  3. A micro-integrated Peltier heat pump for localized on-chip temperature control

    Energy Technology Data Exchange (ETDEWEB)

    Shafai, C.; Brett, M.J. [Alberta Univ., Edmonton, AB (Canada). Dept. of Electrical Engineering

    1996-12-31

    Peltier heat pumps are often used for the thermal regulation of small-sized sensors and electronics such as integrated circuits. Integrated Peltier devices would need less power and would provide better thermal compensation than exterior devices. A thin-film Peltier heat pump was designed and built using standard semiconductor patterning and etching techniques. Chrome-gold and bismuth telluride metallization formed the thermoelectric junctions. A maximum heat-pumping rate of -24 uW at a current of 0.89 mA was achieved when operating in the cooling mode. This pumping rate was proportional to the dimensions of the Peltier device and the thickness of the Bi{sub 2}Te{sub 3} thin film. The performance can be optimized by choosing an appropriate geometry for the Peltier device. 20 refs., 5 figs.

  4. Evaluation of sub-fascial lidocaine infusion in post-operative pain management following laparotomy

    Directory of Open Access Journals (Sweden)

    F. Eshghi

    2008-01-01

    Full Text Available  AbstractBackground and Purpose: One of the important problems of major abdominal surgery is post-operative pain control. There are different modalities to control the pain after surgery, such as oral, local or intravenous analgesic drugs, regional nerve block, epidural catheters and pain killer pumps with their own benefits and complications. The aim of this study was to evaluate the effect of continuous peritoneal infusion of lidocaine by a pain killer pump for post-operative pain management following laparotomy.Materials and Methods: This double blind randomized clinical trial was performed on 76 patients (38 cases and 38 controls who underwent laparotomy with midline incision, in Imam Hospital, Sari, Iran, in 2008. Two groups were matched in age and sex. After surgery a catheter infusion pump was prepared for all patients. In case group, 2% lidocaine (20mg/kg/day and for control, normal saline infused for 24 hours. Pain score (Visual Analog Scale, blood pressure, heart rate, respiratory rate, temperature and analgesic requirement was evaluated in 4, 10, 16 and 24 hours after surgery. Results analyzed by means of SPSS (15 software and chi-square, t test and repeated measurement. The p value less than 0.05 was considered to be significant statistically.Results: 76 patients, 39 (51.3% females and 37 (48.7% males, with mean age of 47.03±15.2 years were studied. There was no significant difference in age, sex and weight between two groups. The mean of admission days was 5.03±0.6 in case and 5.29±1.3 in control, with no significant difference between them. Mean of opiod consumption was 16.05±13.05 mg and 25.39±11.4 mg in case and control respectively (P= 0.002. Mean of VAS score, blood pressure, heart rate, respiratory rate and temperature in case group was less than control group and the difference was significant statistically. Pain severity changes during 4, 10, 16 and 24 hours following surgery were significantly different in two

  5. Auto-control of pumping operations in sewerage systems by rule-based fuzzy neural networks

    OpenAIRE

    Chiang, Y.-M.; Chang, L.-C.; Tsai, M.-J.; Wang, Y. -F.; Chang, F.-J.

    2011-01-01

    Pumping stations play an important role in flood mitigation in metropolitan areas. The existing sewerage systems, however, are facing a great challenge of fast rising peak flow resulting from urbanization and climate change. It is imperative to construct an efficient and accurate operating prediction model for pumping stations to simulate the drainage mechanism for discharging the rainwater in advance. In this study, we propose two rule-based fuzzy neural networks, adaptive neuro-fuzzy infere...

  6. A New Optimum Frequency Controller of Hybrid Pumping System: Bond Graph Modeling-Simulation and Practice with ARDUINO Board

    Directory of Open Access Journals (Sweden)

    MEZGHANI Dhafer

    2017-01-01

    Full Text Available The strategy of rural development in Tunisia needs to include as one of its priorities: the control of water. In seeking solutions for the energy control dedicated to pumping, it seems interesting to know the benefits of a new technique based on the complementarities of two renewable energy sources such as solar and wind power. The climate’s dependence requires a complex modelling and more optimization methods for controlling of hybrid system. Moreover, in recent years, technological progression at hardware and software enables researchers to process these optimization problems using embedded platforms. For this paper, we apply the approach bond graph to model a complex system. Our hybrid pumping installation contains a photovoltaic generator, a wind source, converters and an induction motor-pump group. The numerical closed-loop simulation of the complete model in an appropriate environment allows us to generate an optimisation control whose the appropriate frequency depends on meteorological conditions (wind speed, insulation and temperature. The implementation of this control and the experimental measurements validate the optimum efficiency and verify operation reliability of our hybrid structure.

  7. A method for control of an implantable rotary blood pump for heart failure patients using noninvasive measurements.

    Science.gov (United States)

    Lim, Einly; Alomari, Abdul-Hakeem H; Savkin, Andrey V; Dokos, Socrates; Fraser, John F; Timms, Daniel L; Mason, David G; Lovell, Nigel H

    2011-08-01

    We propose a deadbeat controller for the control of pulsatile pump flow (Q(p) ) in an implantable rotary blood pump (IRBP). Noninvasive measurements of pump speed and current are used as inputs to a dynamical model of Q(p) estimation, previously developed and verified in our laboratory. The controller was tested using a lumped parameter model of the cardiovascular system (CVS), in combination with the stable dynamical models of Q(p) and differential pressure (head) estimation for the IRBP. The control algorithm was tested with both constant and sinusoidal reference Q(p) as input to the CVS model. Results showed that the controller was able to track the reference input with minimal error in the presence of model uncertainty. Furthermore, Q(p) was shown to settle to the desired reference value within a finite number of sampling periods. Our results also indicated that counterpulsation yields the minimum left ventricular stroke work, left ventricular end diastolic volume, and aortic pulse pressure, without significantly affecting mean cardiac output and aortic pressure.

  8. Microfabricated infuse-withdraw micropump component for an integrated inner-ear drug-delivery platform.

    Science.gov (United States)

    Tandon, Vishal; Kang, Woo Seok; Spencer, Abigail J; Kim, Ernest S; Pararas, Erin E L; McKenna, Michael J; Kujawa, Sharon G; Mescher, Mark J; Fiering, Jason; Sewell, William F; Borenstein, Jeffrey T

    2015-04-01

    One of the major challenges in treatment of auditory disorders is that many therapeutic compounds are toxic when delivered systemically. Local intracochlear delivery methods are becoming critical in emerging treatments and in drug discovery. Direct infusion via cochleostomy, in particular, is attractive from a pharmacokinetics standpoint, as there is potential for the kinetics of delivery to be well-controlled. Direct infusion is compatible with a large number of drug types, including large, complex molecules such as proteins and unstable molecules such as siRNA. In addition, hair-cell regeneration therapy will likely require long-term delivery of a timed series of agents. This presents unknown risks associated with increasing the volume of fluid within the cochlea and mechanical damage caused during delivery. There are three key requirements for an intracochlear drug delivery system: (1) a high degree of miniaturization (2) a method for pumping precise and small volumes of fluid into the cochlea in a highly controlled manner, and (3) a method for removing excess fluid from the limited cochlear fluid space. To that end, our group is developing a head-mounted microfluidics-based system for long-term intracochlear drug delivery. We utilize guinea pig animal models for development and demonstration of the device. Central to the system is an infuse-withdraw micropump component that, unlike previous micropump-based systems, has fully integrated drug and fluid storage compartments. Here we characterize the infuse-withdraw capabilities of our micropump, and show experimental results that demonstrate direct drug infusion via cochleostomy in animal models. We utilized DNQX, a glutamate receptor antagonist that suppresses CAPs, as a test drug. We monitored the frequency-dependent changes in auditory nerve CAPs during drug infusion, and observed CAP suppression consistent with the expected drug transport path based on the geometry and tonotopic organization of the cochlea.

  9. Energy conservation by application of a volume-flow-dependent linear speed control for pumps and blowers. Energiebesparing met volumestroomafhankelijke toerenregeling voor pompen en ventilatoren

    Energy Technology Data Exchange (ETDEWEB)

    Slagt, G. (Nederlands Omroepproduktie Bedrijf NV, Hilversum (Netherlands))

    1990-06-01

    The Energie-Einspar-Technik uses a sensor to measure flow rates. A coupled microprocessor is used to control the thyristor power control unit or the frequency transformer of an electromotor. Two pumps, driven by 22 kW-electromotors and used for coldwater transport in buildings, are compared in order to test this system. The thyristor power control unit of one of the electromotors was replaced by a frequency transformer controlled by the microprocessor. Energy conservation for the latter electromotor has been 35% during the test period (15 days for each pump; the pumps can replace one another). Measured electric power consumption data are presented. 1 ill., 1 tab.

  10. Using LDR as Sensing Element for an External Fuzzy Controller Applied in Photovoltaic Pumping Systems with Variable-Speed Drives.

    Science.gov (United States)

    Maranhão, Geraldo Neves De A; Brito, Alaan Ubaiara; Leal, Anderson Marques; Fonseca, Jéssica Kelly Silva; Macêdo, Wilson Negrão

    2015-09-22

    In the present paper, a fuzzy controller applied to a Variable-Speed Drive (VSD) for use in Photovoltaic Pumping Systems (PVPS) is proposed. The fuzzy logic system (FLS) used is embedded in a microcontroller and corresponds to a proportional-derivative controller. A Light-Dependent Resistor (LDR) is used to measure, approximately, the irradiance incident on the PV array. Experimental tests are executed using an Arduino board. The experimental results show that the fuzzy controller is capable of operating the system continuously throughout the day and controlling the direct current (DC) voltage level in the VSD with a good performance.

  11. Using LDR as Sensing Element for an External Fuzzy Controller Applied in Photovoltaic Pumping Systems with Variable-Speed Drives

    Directory of Open Access Journals (Sweden)

    Geraldo Neves De A. Maranhão

    2015-09-01

    Full Text Available In the present paper, a fuzzy controller applied to a Variable-Speed Drive (VSD for use in Photovoltaic Pumping Systems (PVPS is proposed. The fuzzy logic system (FLS used is embedded in a microcontroller and corresponds to a proportional-derivative controller. A Light-Dependent Resistor (LDR is used to measure, approximately, the irradiance incident on the PV array. Experimental tests are executed using an Arduino board. The experimental results show that the fuzzy controller is capable of operating the system continuously throughout the day and controlling the direct current (DC voltage level in the VSD with a good performance.

  12. The Performance Test for Reactor Coolant Pump (RCP) adopting Variable Restriction Orifice Type Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S.; Bae, B. U.; Cho, Y. J. and others

    2014-05-15

    The design values of the RCPTF are 17.2 MPa, 343 .deg. C, 11.7 m{sup 3}/s, and 13 MW in the maximum pressure, temperature, flow rate, and electrical power, respectively. In the RCPTF, various types of tests can be performed including a hydraulic performance test to acquire a H-Q curve as well seal transient tests, thrust bearing transient test, cost down test, NPSHR verification test, and so on. After a commissioning startup test was successfully perfomed, mechanical structures are improved including a flow stabilizer and variable restriction orifice. Two- branch pipe (Y-branch) was installed to regulate the flow rate in the range of performance tests. In the main pipe, a flow restrictor (RO: Restriction Orifice) for limiting the maximum flow rate was installed. In the branch pipe line, a globe valve and a butterfly valves for regulating the flow rate was located on the each branch line. When the pressure loss of the valve side is smaller than that of the RO side, the flow rate of valve side was increasing and the flow disturbance was occurred in the lower pipe line. Due to flow disturbnace, it is to cause an error when measuring RCP head and flow measurement of the venturi flow meter installed in the lower main pipe line, and thus leading to a decrease in measurement accuracy as a result. To increase the efficiency of the flow control availability of the test facility, the variable restriction orifice (VRO) type flow control valve was designed and manufactured. In the RCPTF in KAERI, the performance tests and various kinds of transient tests of the RCP were successfully performed. In this study, H-Q curve of the pump using the VRO revealed a similar trend to the result from two ROs. The VRO was confirmed to effectively cover the full test range of the flow rate.

  13. Long-term outcome of insulin pump therapy in children with type 1 diabetes assessed in a large population-based case-control study.

    Science.gov (United States)

    Johnson, Stephanie R; Cooper, Matthew N; Jones, Timothy W; Davis, Elizabeth A

    2013-11-01

    We determined the impact of insulin pump therapy on long-term glycaemic control, BMI, rate of severe hypoglycaemia and diabetic ketoacidosis (DKA) in children. Patients on pump therapy at a single paediatric tertiary hospital were matched to patients treated by injections on the basis of age, duration of diabetes and HbA1c at the time of pump start. HbA1c, anthropometric data, episodes of severe hypoglycaemia and rates of hospitalisation for DKA were collected prospectively. A total of 345 patients on pump therapy were matched to controls on injections. The mean age, duration of diabetes at pump start and length of follow-up were 11.4 (± 3.5), 4.1 (± 3.0) and 3.5 (± 2.5) years, respectively. The mean HbA1c reduction in the pump cohort was 0.6% (6.6 mmol/mol). This improved HbA1c remained significant throughout the 7 years of follow-up. Pump therapy reduced severe hypoglycaemia from 14.7 to 7.2 events per 100 patient-years (p pump cohort over the same period from 6.8 to 10.2 events per 100 patient-years. The rate of hospitalisation for DKA was lower in the pump cohort (2.3 vs 4.7 per 100 patient-years, p = 0.003) over the 1,160 patient-years of follow-up. This is the longest and largest study of insulin pump use in children and demonstrates that pump therapy provides a sustained improvement in glycaemic control, and reductions of severe hypoglycaemia and hospitalisation for DKA compared with a matched cohort using injections.

  14. LMI Approach to Robust H∞/H2 Controller Design with Regional Poles Constraint of a Pump-Motor System

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The time domain guideposts requirements of a pump-motor system is transferred into a series of constraints which express the robust performance upper bound and regional poles limits of the closed loop system. Then the servo system control problem is transferred into the problem of robust performance optimizing under regional poles constrains described by linear matrix inequality (LMI). These LMIs are easy to solve through the Matlab LMI-toolbox. Simulations indicate that the controller has excellent dynamic, static and disturbance rejection performance, and the control system is robust and has perfect H2 performance to the bounded external torque disturbance.

  15. Cooperative Suction by Vertical Capillary Array Pump for Controlling Flow Profiles of Microfluidic Sensor Chips

    Directory of Open Access Journals (Sweden)

    Emi Tamechika

    2012-10-01

    Full Text Available A passive pump consisting of integrated vertical capillaries has been developed for a microfluidic chip as an useful component with an excellent flow volume and flow rate. A fluidic chip built into a passive pump was used by connecting the bottoms of all the capillaries to a top surface consisting of a thin layer channel in the microfluidic chip where the thin layer channel depth was smaller than the capillary radius. As a result the vertical capillaries drew fluid cooperatively rather than independently, thus exerting the maximum suction efficiency at every instance. This meant that a flow rate was realized that exhibited little variation and without any external power or operation. A microfluidic chip built into this passive pump had the ability to achieve a quasi-steady rather than a rapidly decreasing flow rate, which is a universal flow characteristic in an ordinary capillary.

  16. DC electromagnetic pump applied to liquid metal flow control used in fast reactors; Bomba eletromagnetica de corrente continua aplicada ao controle de escoamento de metais liquidos utilizados em reatores rapidos

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Eduardo M.; Braz Filho, Francisco A.; Guimaraes, Lamartine N.F. [Centro Tecnico Aeroespacial (CTA), Sao Jose dos Campos, SP (Brazil). Inst. de Estudos Avancados (IEAv)]. E-mail: Eduardo@ieav.cta.br; fbraz@ieav.cta.br; guimarae@ieav.cta.br

    2005-07-01

    Electromagnetic pumps use Faraday principle to liquid metal flow control, where DC electric current and magnetic field applied produce the Lorentz force on the liquid metal. In this paper the results of the computational simulation are compared to experimental data of Mercury DC electromagnetic pump operation and the BEMC-1 code is used to evaluation of DC electromagnetic pump performance applied to liquid metal flow control as Sodium, Lead and Bismuth, used in fast reactors. (author)

  17. Intravenous proton pump inhibitors for peptic ulcer bleeding: Clinical benefits and limits.

    Science.gov (United States)

    Cheng, Hsiu-Chi; Sheu, Bor-Shyang

    2011-03-16

    Peptic ulcer bleeding is a common disease and recurrent bleeding is an independent risk factor of mortality. Infusion with proton pump inhibitors (PPIs) prevents recurrent bleeding after successful endoscopic therapy. A gastric acidic environment of less than pH 5.4 alters coagulation function and activates pepsin to disaggregate platelet plugs. Gastric acid is secreted by H(+), K(+)-ATPase, naming the proton pump. This update review focuses on the mechanism and the role of PPIs in the clinical management of patients with peptic ulcer bleeding. An intravenous omeprazole bolus followed by high-dose continuous infusion for 72 h after successful endoscopic therapy can prevent the recurrent bleeding. In the Asian, however, the infusion dosage can possibly be diminished whilst preserving favorable control of the intragastric pH and thereby still decreasing rates of recurrent bleeding. Irrespective of the infusion dosage of PPIs, rates of recurrent bleeding remain high in patients with co-morbidities. Because recurrent peptic ulcer bleeding may be prolonged in those with co-morbidities, a low-dose infusion of IV PPIs for up to 7-day may result in better control of recurrent bleeding of peptic ulcers. Due to the inter-patient variability in CYP2C19 genotypes, the infusion form of new generation PPIs, such as esomeprazole, should be promising for the prevention of recurrent bleeding. This article offers a comprehensive review of clinical practice, highlighting the indication, the optimal dosage, the duration, and the potential limitation of PPIs infusion for peptic ulcer bleeding.

  18. Hemolysis during cardiac extracorporeal membrane oxygenation: a case-control comparison of roller pumps and centrifugal pumps in a pediatric population.

    Science.gov (United States)

    Byrnes, Jonathan; McKamie, Wes; Swearingen, Christopher; Prodhan, Parthak; Bhutta, Adnan; Jaquiss, Robert; Imamura, Michiaki; Fiser, Richard

    2011-01-01

    Extracorporeal membrane oxygenation (ECMO) is a lifesaving therapy, which has been used for the support of children with a broad range of diseases. Two pumps of differing mechanisms have been used to generate the extracorporeal flow: roller-head pumps and centrifugal pumps. Seven patients supported during ECMO with Levitronix Centrimag (Centrimag group [CG]) were matched to 14 patients supported with Stockert-Shiley SIII (Stockert-Shiley group [SSG]) at a single institution from July 2007 to July 2009. We hypothesized that hemolysis as measured by plasma-free hemoglobin (PFH) is elevated in the SSG versus the CG during cardiac ECMO. Categorical data were analyzed using Fisher's exact test. Plasma-free hemoglobin differences between groups were analyzed using both Wilcoxon rank sum and beta regression. Overall, SSG patients had two times the odds of having a higher PFH than CG patients adjusting for repeated measures (odds ratio [OR] = 1.96, 95% confidence interval [CI]: [1.15-3.34], p pump supported group, when compared with the CG, a centrifugal pump supported group. Differences in circuit life did not reach statistical significance. This pilot study contrasts with past studies, which have demonstrated more hemolysis occurring with centrifugal pumps when compared with roller-head pumps.

  19. Electronic Unit Pump Test Bench Development and Pump Properties Research

    Institute of Scientific and Technical Information of China (English)

    LIU Bo-lan; HUANG Ying; ZHANG Fu-jun; ZHAO Chang-lu

    2006-01-01

    A unit pump test bench is developed on an in-line pump test platform. The bench is composed of pump adapting assembly, fuel supply subsystem, lubricating subsystem and a control unit. A crank angle domain injection control method is given out and the control accuracy can be 0.1° crank degree. The bench can test bot h mechanical unit pump and electronic unit pump. A test model-PLD12 electronic unit pump is tested. Full pump delivery map and some influence factors test is d one. Experimental results show that the injection quantity is linear with the de livery angle. The quantity change rate is 15% when fuel temperature increases 30℃. The delivery quantity per cycle increases 30mg at 28V drive voltage. T he average delivery difference for two same type pumps is 5%. Test results show that the bench can be used for unit pump verification.

  20. An advanced automation system for operation of Sao Paulo pumping stations from TRANSPETRO Master Control Center - CNCO

    Energy Technology Data Exchange (ETDEWEB)

    Corcioli, Mario Sergio; Barreto, Camila Maria Benevenuto [TRANSPETRO, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    Since 2000 the operations of the TRANSPETRO pumping stations in the state of Sao Paulo region began to be transferred from local control centers located at the transfer and storage terminals to the National Operational Control Center (CNCO) of TRANSPETRO, located at the headquarters of the company, in Rio de Janeiro. The proposed paper aims to presenting an overview of the automation system that was developed to enable such pumping stations to be operated from CNCO in a reliable and secure manner, focusing on tools that offer an embedded system alarms completely free of false alarms with automatic determining of the root cause, and also automatic and advanced diagnoses of problems caused by failures of hardware, human error and abnormal conditions of the process, providing the CNCO SCADA system of accurate and quality information that help operators to make decisions. The referred automation system was integrated for the first time to CNCO SCADA system in 2000, for pipeline pumps of Osvat (Sao Sebastiao - Vale do Paraiba pipeline) station at the Sao Sebastiao Terminal - northern coast of Sao Paulo region. (author)

  1. An anthropomorphic transhumeral prosthesis socket developed based on an oscillometric pump and controlled by force-sensitive resistor pressure signals.

    Science.gov (United States)

    Razak, N A Abd; Gholizadeh, H; Hasnan, N; Osman, N A Abu; Fadzil, S S Mohd; Hashim, N A

    2017-02-01

    While considering the importance of the interface between amputees and prosthesis sockets, we study an anthropomorphic prosthesis socket whose size can be dynamically changed according to the requirements of the residual limb. First, we introduce the structure and function of the anthropomorphic prosthesis socket. Second, we study the dynamic model of the prosthesis system and analyze the dynamic characteristics of the prosthesis socket system, the inputs of an oscillometric pump, and the control mechanism of force-sensitive resistor (FSR) pressure signals. Experiments on 10 healthy subjects using the designed system yield an average detection result between 102 and 112 kPa for the FSR pressure sensor and 39 and 41 kPa for the oscillometric pump. Results show the function of the FSR pressure signal in maintaining the contact pressure between the sockets and the residual limb. The potential development of an auto-adjusted socket that uses an oscillometric pump system will provide prosthetic sockets with controllable contact pressure at the residual limb. Moreover, this development is an attractive research area for researchers involved in rehabilitation engineering, prosthetics, and orthotics.

  2. Baking-powder driven centripetal pumping controlled by event-triggering of functional liquids

    DEFF Research Database (Denmark)

    Kinahan, David J.; Burger, Robert; Vembadi, Abhishek

    2015-01-01

    This paper reports radially inbound pumping by the event-triggered addition of water to on-board stored baking powder in combination with valving by an immiscible, high-specific weight liquid on a centrifugal microfluidic platform. This technology allows making efficient use of precious real estate...

  3. Receptor kinase-mediated control of primary active proton pumping at the plasma membrane

    DEFF Research Database (Denmark)

    Fuglsang, AT; Kristensen, A; Cuin, TA

    2014-01-01

    heterologous expression system, the introduction of a negative charge at this position caused pump activation. Application of PSY1 to plant seedlings induced rapid in planta phosphorylation at Thr-881, concomitant with an instantaneous increase in proton efflux from roots. The direct interaction between AHA2...

  4. Controlled delivery of nanosuspensions from osmotic pumps: zero order and non-zero order kinetics.

    Science.gov (United States)

    Hill, Alexandra; Geissler, Simon; Weigandt, Markus; Mäder, Karsten

    2012-03-28

    Nanosuspensions have gained great interest in the last decade as a formulation tool for poorly soluble drugs. By decreasing particle sizes nanosuspensions enhance dissolution rate and bioavailability of the active pharmaceutical ingredient. Micro-osmotic pumps are widely used in experimental pharmacology and offer a tool of interest for the sustained release of nanosuspensions via the intraperitoneal or subcutaneous application site. The purpose of the present study was to investigate in-vitro the influence of (1) nanosuspension viscosity, (2) pump orifice position and (3) formulation osmolality on the delivery behavior of formulations in implantable osmotic systems. Therefore fenofibrate nanosuspension, methylene blue and fluorescein sodium solutions were chosen as model formulations. They were released in water or isotonic saline solution and drug/dye concentrations were determined by HPLC/UV. Release of nanosuspension particles in low viscous formulations resulted in a burst whereas increasing the viscosity led to the expected zero order delivery. Pumps with upward-positioned orifices released the nanosuspension in a zero order manner. Within the release of dyes, constant delivery could be ensured up to an osmolality of 486 mO sm/kg; above this value premature release of formulation was observed. The results indicate the requirement of in-vitro experiments prior to in-vivo animal testing for determining the release profiles of osmotic pumps.

  5. Dynamics and control of a heat pump assisted extractive dividing-wall column for bioethanol dehydration

    NARCIS (Netherlands)

    Patraşcu, Iulian; Bildea, Costin Sorin; Kiss, Anton A.

    Recently, a novel heat-pump-assisted extractive distillation process taking place in a dividing-wall column was proposed for bioethanol dehydration. This integrated design combines three distillation columns into a single unit that allows over 40% energy savings and low specific energy requirements

  6. Insulin pump therapy in children with type 1 diabetes

    DEFF Research Database (Denmark)

    Szypowska, Agnieszka; Schwandt, Anke; Svensson, Jannet

    2016-01-01

    BACKGROUND: Intensified insulin delivery using multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) is recommended in children with type 1 diabetes (T1D) to achieve good metabolic control. OBJECTIVE: To examine the frequency of pump usage in T1D children treated...... in SWEET (Better control in Paediatric and Adolescent diabeteS: Working to crEate CEnTers of Reference) centers and to compare metabolic control between patients treated with CSII vs MDI. METHODS: This study included 16 570 T1D children participating in the SWEET prospective, multicenter, standardized...... diabetes patient registry. Datasets were aggregated over the most recent year of treatment for each patient. Data were collected until March 2016. To assess the organization of pump therapy a survey was carried out. RESULTS: Overall, 44.4% of T1D children were treated with CSII. The proportion of patients...

  7. Effect of Target Controlled Infusion of Remifentanil Combined with Sufentanil on Stress Reaction and Postoperative Pain of Elderly Patients in Perioperative Period

    Institute of Scientific and Technical Information of China (English)

    Naser Babaee; Ali Jahangiri Alavi

    2016-01-01

    Objective:To explore the effect of target controlled infusion (TCI) of remifentanil combined with sufentanil on the stress reaction and postoperative pain of elderly patients in perioperative period. Methods: Ninety-four patients receiving general anesthesia who underwent upper abdominal operation selectively were collected and randomly assigned into observation group (n=47) and control group (n=47). The patients in control group were given remifentanil 5 ng/mL for anesthesia induction and 4 ng/mL for anesthesia maintenance. Patient-controlled intravenous analgesia (PCIA) was conducted at the time of suture. The patients in observation group were given remifentanil and sufentanil 2 ng/mL for anesthesia induction and maintenance. PCIA was performed at the time of suture. Systolic blood pressure (SBP), diastolic blood pressure (DBP) and heart rate (HR) of patients in two groups were compared respectively before anesthesia (T1), before intubation (T2), 1 min after intubation (T3), 1 min after laparotomy (T4) and 1 min after extubation (T5). The violent fluctuation times of intraoperative hemodynamics were closely observed. The levels of serum cortisol and glucose before operation, during operation, 12 h and 24 h after operation, visual analogue scale (VAS) scores and doses of analgesics at different postoperative time points were also recorded. Results: Both SBP and DBP at different time points as well as HR at T3 and T4 were signiifcantly lower in observation group than in control group, and the difference was shown statistically significance (P Conclusion: For elderly patients in perioperative period, TCI of remifentanil combined with sufentanil can effectively attenuate the increase of blood pressure and HR, maintain the lfuctuation times of hemodynamics and depth of anesthesia, and decrease the stress reaction and postoperative doses of analgesics.

  8. A Controlled Clinical Study between Hepatic Arterial Infusion with Embolized Curcuma Aromatic Oil and Chemical Drugs in Treating Primary Liver Cancer

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Objective: To evaluate the effectiveness, toxicity and prospective application of hepatic arterial infusion (HAI) with embolized Curcuma Aromatic oil (CAO) in treating primary liver cancer (PLC). Methods: In the treated group, 32 patients with PLC were treated by HAI with 1-3 ml embolized CAO and oral administration of Chinese herbal medicine. In the control group, 32 patients with PLC were treated with transcatheter artery chemoembolization (TACE). Results: In the treated group, one patient attained complete remission (CR) and 13 partial remission (PR), the total effective rate being 43.75%. The level of alpha fetal protein (AFP) turned to normal range in 7 cases and decreased in other 7. In the control group, 10 obtained PR and the total effective rate being 31.25%, AFP level turned to normal in 5 and decreased in 2. There was no statistical significance between the two groups. The incidences of post-embolism Sydrome, such as fever, abdominal pain and vomiting were similar between the two groups but no myelosuppression occurred in the treated group with significant difference as comparing with that in the control group (P<0.01). The mean survival time, median survival time, 1-, 2- and 3-year survival rate in the treated group were 11.5 months, 10 months, 37.5%, 13.3% and 6.9% respectively, while in the control group they were 7.25 months, 6 months, 15.6%, 3.2% and 0% respectively. Better result in mean survival time, median survival time and 1-year survival rate was found in the treated group than that of the control group (P<0.05). Conclusion:HAI with embolized CAO showed a similar good effect in treating PLC as that of TACE, but superior to TACE with longer survival time and milder myelosuppression.

  9. Control de bacteriemia nosocomial pediátrica mediante un programa de cultivo de soluciones parenterales en uso Pediatric nosocomial bacteremia control program based on culturing in use parenteral infusions

    Directory of Open Access Journals (Sweden)

    Juan M. Muñoz

    1999-01-01

    Full Text Available OBJETIVO. Dado que Klebsiella, Enterobacter y Serratia se multiplican en soluciones parenterales y son responsables de una elevada proporción de bacteriemias en los hospitales de México, se propone una estrategia de control mediante la vigilancia microbiológica de las soluciones en uso. MATERIAL Y MÉTODOS. Hospital de enseñanza de segundo nivel con 193 camas. Atiende principalmente pacientes de escasos recursos. En 1992 se inició la vigilancia de la esterilidad de las soluciones parenterales en los servicios pediátricos mediante cuatro estrategias: durante la primera etapa se cultivó el total de soluciones en uso. Durante la segunda se cultivaron muestras aleatoriamente elegidas. Tercera y cuarta etapas con muestreo controlado y dirigido, respectivamente. RESULTADOS. Se han cultivado 1940 infusiones. Se ha observado una reducción de la tasa de contaminación (de 29.6% en 1992 a 12.9% en 1997, pOBJECTIVES. As Klebsiella, Enterobacter and Serratia are capable of growth in IV fluids and these bacteria are commonly implicated in nosocomial bacteremia, a control strategy through microbiological surveilance of in-use parenteral solutions is proposed. MATERIAL AND METHODS. A second level general teaching hospital, serving low-income patients. Through four consecutive strategies, a continous surveillance program of IV fluids sterility in pediatric wards was stablished in 1992. During the first stage all of the in -use solutions were cultured. During the second stage randomly selected samples were studied. Third stage was designed as a case-control study. The last stage included samples drawn in convenience. Positive cultures point out eventual infusion mishandling, as well as high-risk areas and patients. RESULTS. After culturing 1940 parenteral solutions, infusion contamination rates decreased from 29.6% in 1992 to 12.9% in 1997 (p< 0.001. The proportion of Gram-negative rods isolated from blood cultures went from 72.7% to 40.85% (p< 0

  10. Developing Efficient Coordination Schemes to Control Over-Pumping in the Heihe River Basin, China

    Science.gov (United States)

    Pedrazzini, G.

    2015-12-01

    Many wicked water resources problems are approached in a social planner perspective. This not always matches the real institutional and policy-making context, where, rather, multiple decision-makers (DMs) can act independently, or weakly cooperate, ultimately producing system-wide inefficient trade-offs. The idea in this work is to adopt a more realistic approach, where the multi-DMs nature of the problem is preserved and the uncoordinated DMs are driven, thorough coordination mechanisms, towards a more system-wide efficient solution. An agent-based modelling framework linked to a surface and groundwater model is used to design these coordination mechanisms as constraints to the independent agents (i.e., DMs) behaviour. In the Heihe Basin the ongoing introduction of smart meter IC-card systems on farmers' pumping wells will soon allow monitoring and control of abstractions with the goal of preventing further depletion of the resource. The major interest of policy makers in the region concerns the development of new and the improvement of existing legislation on pricing schemes and/or groundwater quotas. The model outcome where agents act rationally but selfishly is compared to the optimal solution at system-level assuming perfect coordination and cooperation. The optimal solutions with respect to the given utility functions are computed using nonlinear optimization with a rolling out time horizon. The Pareto-Frontier is synthesized through an exhaustive sampling of the weight coefficient space and related to the current and to the historical management of the last 4 decades. The best parameter values for the proposed coordination mechanisms are determined and the alternatives are compared with respect to their efficiency and acceptability. Preliminary results suggest that a regulatory tax on groundwater of about a factor 10 of the current resource fee is required to increase the elasticity of the groundwater demand curve such that reducing consumption becomes

  11. A water pumping control system with a programmable logic controller (PLC) and industrial wireless modules for industrial plants--an experimental setup.

    Science.gov (United States)

    Bayindir, Ramazan; Cetinceviz, Yucel

    2011-04-01

    This paper describes a water pumping control system that is designed for production plants and implemented in an experimental setup in a laboratory. These plants contain harsh environments in which chemicals, vibrations or moving parts exist that could potentially damage the cabling or wires that are part of the control system. Furthermore, the data has to be transferred over paths that are accessible to the public. The control systems that it uses are a programmable logic controller (PLC) and industrial wireless local area network (IWLAN) technologies. It is implemented by a PLC, an communication processor (CP), two IWLAN modules, and a distributed input/output (I/O) module, as well as the water pump and sensors. Our system communication is based on an Industrial Ethernet and uses the standard Transport Control Protocol/Internet Protocol for parameterisation, configuration and diagnostics. The main function of the PLC is to send a digital signal to the water pump to turn it on or off, based on the tank level, using a pressure transmitter and inputs from limit switches that indicate the level of the water in the tank. This paper aims to provide a convenient solution in process plants where cabling is not possible. It also has lower installation and maintenance cost, provides reliable operation, and robust and flexible construction, suitable for industrial applications.

  12. Insulin pumps in pregnancy: using technology to achieve normoglycemia in women with diabetes.

    Science.gov (United States)

    Castorino, Kristin; Paband, Rashid; Zisser, Howard; Jovanovič, Lois

    2012-02-01

    Poorly controlled diabetes before conception and during pregnancy among women with pre-existing diabetes can cause major birth defects and spontaneous abortions, as wells as abnormal fetal growth and development including an offspring who is small or large for gestational age, or predisposed to obesity, type 2 diabetes, and metabolic syndrome in his/her lifetime. Conversely, for a woman with pre-existing diabetes, optimizing blood glucose levels before and during early pregnancy can reduce these risks dramatically. As insulin pump technology has evolved, continuous subcutaneous insulin infusion has become a safe and reliable method for treating diabetes during pregnancy. Although pump therapy is often preferred by patients and some experts, insulin pumps have not yet been shown to be superior to multiple daily injections of insulin during pregnancy. In this review of the literature we focus on the use of insulin pumps in the management of diabetes in pregnancy.

  13. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  14. Nonlinear control of variable-displacement self-supplied axial piston pumps; Nichtlineare Regelung von verstellbaren eigenversorgten Axialkolbenpumpen

    Energy Technology Data Exchange (ETDEWEB)

    Fuchshumer, F.; Kemmetmueller, W.; Kugi, A. [Univ. des Saarlandes, Saarbruecken (Germany). Lehrstuhl fuer Systemtheorie und Regelungstechnik

    2007-02-15

    This contribution is concerned with the model-based nonlinear control of a variable-displacement, self-supplied axial piston pump for the application in plastic injection moulding machines. Due to the self-supply mechanism the mathematical model of the pump turns out to be a switched system depending on the direction of movement of the swash plate. The demands on the closed-loop performance with respect to dynamics and stationary accuracy on the assumption of unknown loads are basically derived from the injection process of plastic injection moulding machines. The control concept being derived consists of an inversion-based feedforward controller, an adaptive backstepping controller for the stabilization of the trajectory error system and an estimator for the unknown load. The controller and the estimator design are performed for each subsystem of the overall switched system separately. The stability of the overall closed-loop system can be proven in a systematic way by utilizing the theory of multiple Lyapunov functions. Experimental results on a test-stand show an excellent performance of the closed-loop system for all test scenarios. (orig.)

  15. Determination of the critical time of canal storage capacity controlled by cross pump stations “Case Study: Egypt, El-Salam Canal”

    Directory of Open Access Journals (Sweden)

    Ahmed M. El-Belasy

    2013-06-01

    Full Text Available El-Salam Pump Stations (1 and (2 are located at 22.1 km and 54.3 km respectively at El-Salam Canal. When El-Salam Pump Station (1 is in operation, and switching off El-Salam Pump Station (2, water level rises upstream El-Salam Pump Station (2. Water level overtops El-Salam Pump Station (2 and banks upstream it. Flooding then takes place as Wadi El Noqra Canal, Egypt. This necessitates discharging the excess water to protect the pump station and the canal from water flooding when the electricity is shut down. The hydrodynamic simulation of El-Salam Canal determinates the critical time for storage capacity according to location and type of emergency spillways through the numerical model to prevent water overtopping upstream pump stations. Determination of the critical time of storage capacity is considered as a new parameter in case of the hydraulic design of the canal controlled by cross pump stations.

  16. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    of membrane proteins: P-type ATPase pumps. This article takes the reader on a tour from Aarhus to Copenhagen, from bacteria to plants and humans, and from ions over protein structures to diseases caused by malfunctioning pump proteins. The magazine Nature once titled work published from PUMPKIN ‘Pumping ions......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  17. Control of perpendicular magnetic anisotropy and spin pumping damping in MgO/CoFeB/ Ta/Pt structures

    Science.gov (United States)

    Zhu, Zhendong; Chen, Shaohai; Zhao, Bingcheng; Jin, Q. Y.; Chen, Jingsheng; Zhang, Zongzhi

    2017-09-01

    The perpendicular magnetic anisotropy (PMA) and spin pumping induced magnetic damping of CoFeB films can be significantly tuned by the adjacent nonmagnetic layer (Ta or Pt). For the CoFeB/Pt(t Pt) structure, both PMA strength and magnetic damping increase with t Pt, due to the enhanced interfacial orbital hybridization and spin pumping effects, respectively. By inserting a thin Ta interlayer between CoFeB and Pt, the magnetic easy axis immediately turns into in-plane direction. Meanwhile, time-resolved magneto-optical Kerr effect measurement shows an obvious reduction in the magnetic damping, which can be explained as the increase of spin current backflow and the decrease of interfacial spin-mixing conductivity. As the Ta interlayer thickness (t Ta) increases, the effective damping parameter α s measured at saturation field initially decreases and eventually reaches a constant value of 0.027. The α s value at t Ta  >  5 nm does not change regardless of the top Pt layer, implying the influence of Pt is completely isolated and the spin diffusion length of Ta is around 5 nm. Our findings provide more insights into the control of PMA strength and spin pumping contribution to magnetic damping.

  18. Cavity-induced phase stability to decelerate a fast molecular beam via feedback-controlled time-varying optical pumps

    CERN Document Server

    Lan, Zhihao

    2014-01-01

    We have identified a novel phase stability mechanism from the intracavity field-induced self-organization of a fast-moving molecular beam into travelling molecular packets in the bad cavity regime, which is then used to decelerate the molecular packets by feedback-controlled time-varying laser pumps to the cavity. We first applied the linear stability analysis to derive an expression for this self-organization in the adiabatic limit and show that the self-organization of the beam leads to the formation of travelling molecular packets, which in turn function as a dynamic Bragg grating, thus modulating periodically the intracavity field by superradiant scattering of the pump photons. The modulation encodes the position information of the molecular packets into the output of the intracavity field instantaneously. We then applied time-varying laser pumps that are automatically switched by the output of the intracavity field to slow down the molecular packets via a feedback mechanism and found that most of the mol...

  19. Evaluation of bias in predicted and measured propofol concentrations during target-controlled infusions in obese Japanese patients: an open-label comparative study.

    Science.gov (United States)

    Tachibana, Nobuko; Niiyama, Yukitoshi; Yamakage, Michiaki

    2014-12-01

    Target-controlled infusions (TCIs) of propofol are commonly used for general anaesthesia. The Marsh model pharmacokinetic parameter set incorporated in TCI devices for propofol could increase bias when used in obese patients. The purpose of this study was to assess the optimal predicted blood concentration (Cp) of 4.0 μg ml of propofol using a correction formula including BMI and to evaluate the influences on propofol concentration in obese patients. An open-label, comparative study. Sapporo Medical University Hospital, Japan, from October 2011 to December 2013. Seventy-five adults scheduled for elective surgery under general anaesthesia with the following exclusion criteria: less than 30 or more than 65 years of age; American Society of Anesthesiologists status 3 to 5; allergy to propofol; the daily use of psychoactive drugs; known or suspected drug or alcohol abuse; and cardiac, hepatic, renal or neurological impairment. Propofol was administered and maintained at a Cp of 4.0 μg ml using a TCI device programmed with the Marsh pharmacokinetic model. Arterial blood samples were collected at 15, 30, 60, 90, 120, 150 and 180 min after the start of the infusion, and the measured propofol concentration (Cm) was determined. After calculation of the adjustment formula using the corrected Cp of 69 patients, we then applied the corrected Cp to five other obese patients. The median performance error (MDPE) and median absolute performance error (MDAPE) were calculated to measure bias at each time point. We analysed 333 samples from the 69 individuals. There was a significant correlation between BMI and Cm, which tended be greater than 4.0 μg ml in obese patients. Our new method improved MDPE and MDAPE from a range of 20 to 40 for both, to ranges of -11.3 to -1.8 and 8.8 to 11.5, respectively. BMI influences blood propofol concentrations, leading to the possibility of overdosage of propofol in obese patients when the Marsh model is used to assess propofol

  20. Calculations of Nonlinear Wave-Packet Interferometry Signals in the Pump-Probe Limit as Tests for Vibrational Control over Electronic Excitation Transfer

    CERN Document Server

    Biggs, Jason D

    2009-01-01

    The preceding paper describes a strategy for externally influencing the course of short-time electronic excitation transfer (EET) in molecular dimers and observing the process by nonlinear wave-packet interferometry (nl-WPI). Within a sample of isotropically oriented dimers having a specified internal geometry, a vibrational mode internal to the acceptor chromophore can be preferentially driven by electronically nonresonant impulsive stimulated Raman (or resonant infrared) excitation with a short polarized control pulse. A subsequent electronically resonant polarized pump then preferentially excites the donor, and EET ensues. Here we test both the control strategy and its spectroscopic investigation-with some sacrifice of amplitude-level detail-by calculating the pump-probe difference signal. That signal is the limiting case of the control-influenced nl-WPI signal in which the two pulses in the pump pulse-pair coincide, as do the two pulses in the probe pulse-pair. We present calculated pump-probe difference ...

  1. Retinal characteristics during 1 year of insulin pump therapy in type 1 diabetes: a prospective, controlled, observational study.

    Science.gov (United States)

    Klefter, Oliver Niels; Hommel, Eva; Munch, Inger Christine; Nørgaard, Kirsten; Madsbad, Sten; Larsen, Michael

    2016-09-01

    To investigate changes in retinal metabolism, function, structure and morphology in relation to initiation of insulin pump therapy (continuous subcutaneous insulin infusion, CSII). Visual acuity, retinopathy level, dark adaptation kinetics, retinal and subfoveal choroidal thickness, macular perfusion velocities, retinal vessel diameters and blood oxygen saturations were measured at baseline and after 1, 4, 16, 32 and 52 weeks in 31 patients with type 1 diabetes who started CSII and 20 patients who continued multiple daily insulin injections (MDI). One year of CSII reduced haemoglobin A1c (HbA1c ) by 1.6% (17.8 mmol/mol) compared with 0.3% (3.1 mmol/mol) in the MDI group (p < 0.0001). Central retinal thickness increased by 1.5% in the CSII group (within-group p = 0.0098; between-group p = 0.063) without producing macular oedema. No detectable change was found in any other primary outcome measure. The proportion of patients with retinopathy worsening did not differ between groups. At baseline, longer disease duration was associated with higher retinal artery oxygen saturation (p = 0.014) and lower macular venous perfusion velocity (p = 0.045). One year of CSII led to an HbA1c reduction relative to continued MDI and a small increase in retinal thickness but not to early retinopathy worsening or to changes in retinal vascular, structural or functional characteristics. Longer duration of type 1 diabetes appears to be associated with lower macular venous perfusion velocity and higher retinal artery oxygen saturation. The latter could potentially reflect cumulative glycaemia. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  2. Intraperitoneal insulin infusion: on the way to the artificial pancreas

    Directory of Open Access Journals (Sweden)

    Vladimir Aleksandrovich Karpel'ev

    2015-06-01

    Full Text Available Creating an "artificial pancreas" (a "closed loop" insulin pump, with self-adjusting insulin abilities, based on real time continuous glucose monitoring data – is one of the most actual medical challenges of modern engineering and cybernetics.Artificial pancreas (AP prototypes based on wearable insulin pump with subcutaneous insulin delivery are still problematic, mainly because of slow insulin pharmacokinetics. Intravenous insulin infusion via AP allows effectively maintain euglycaemia for inpatients, due to insulin pharmacokinetics and pharmacodynamics advantages. Unfortunately, it can’t be used for outpatients. Intraperitoneal insulin infusion is still relatively infrequently used in the world, but it is a promising alternative, compared to both previous methods due to a physiological action profile, fast insulin pharmacokinetics, relatively better safety and availability for outpatient usage.The purpose of this review is to describe the intraperitoneal insulin infusion features for diabetes patients at a point of AP creation perspectives. 

  3. Physico-chemical stability of butorphanol-tramadol and butorphanol-fentanyl patient-controlled analgesia infusion solutions over 168 hours.

    Science.gov (United States)

    Chen, Fuchao; Fang, Baoxia; Li, Peng; Zhu, Xuesong; Zhou, Benhong

    2014-08-01

    This study was to investigate the physical and chemical compatibility of butorphanol with tramadol or fentanyl in 0.9% sodium chloride injections for patient controlled analgesia administration. The solutions were prepared in polyvinyl chloride (PVC) infusion bags and stored without protected from light exposure at room temperature (25 degrees C) or refrigerated (4 degrees C). Over a period of 168 hours, stabilities were determined by visual inspection, pH measurement, and high-pressure liquid chromatography (HPLC) assay of drug concentrations. At both temperatures, admixtures of butorphanol-tramadol and butorphanol-fentanyl were clear in appearance, and no color change or precipitation was observed during the study period. The maximum losses obtained were lower than 5% for the three drugs after 168 hours of storage. The results indicate that, at ambient or refrigerated storage conditions, the drug mixtures of butorphanol-tramadol and butorphanol-fentanyl in 0.9% sodium chloride injections were physically and chemically stable for at least 168 hours when stored in PVC syringes.

  4. COMPARISON OF EPIDURAL ANESTHESIA AND POSTOPERATIVE ANALGESIA WITH ROPIVACAINE AND FENTANYL IN OFF - PUMP CORONARY ARTERY BYPASS GRAFTING: A RANDOMIZED, CONTROLLED STUDY

    Directory of Open Access Journals (Sweden)

    Kaushal

    2014-01-01

    Full Text Available BACKGROUND: Our aim was to assess the efficacy of thoracic epidural anesthesia followed by postoperative epidural infusion with ropivacaine and Fentanyl in off - pump coronary bypass grafting. INTRODUCTION : In cardiosurgical patients, high thoracic epidural anesthesia (EA with local anesthetics and opioids can provide effective analgesia and reduce the number of perioperative complications. However, the use of EA in coronary surgery is controversial, and it is still unclear whether EA influences lung fluid balance , cardiopulmonary function and clinical outcome in OPCAB. Thus, the method requires further evaluation and its potential benefits in coronary patients should be weighed against its risks. MATERIALS AND METHODS : A prospective study was performed in 4 0 patients undergoing coronary artery bypass surgery who received high thoracic epidural analgesia. Group 1 received thoracic epidural 0.2% ropivacaine (bolus 10 ml, 10 min before starting surgery while group 2 pts. received Fentanyl 2 mcg/ml (bolus 10 ml , 10 min before starting surgery, then rate of epidural infusion adjusted between 3 - 8 ml/ hr. of the same concentration according to response. The Regimens aimed at a visual analog scale (VAS score < or = 4/10 . Hemodynamic parameters and blood gases were measured from extubation till 24 h after OPCAB. RESULTS : O utcome measures included the incidence of Visual Analogue Score (VAS < or =4/10, infusion rate adjustments and side - effects. Patients receiving ropivacaine were less likely to experience pain < or =4/10 (P' = 0.002; the infusion rate was lower (P' = 0.024; required less rate adjustments (P' = 0.001; a less need for noradrenaline (P' = 0.001 and antiemetic drugs (P' = 0.001. There were no significant differences between the groups for sedation s cores or the incidence of respiratory depression. CONCLUSION : This study suggests that ropivacaine 0.2% may be superior to fentanyl 2 microg/ml. We found a reduced number of

  5. [Bacteriological control of blood preservation, production of infusion solutions and dry human plasma under conditions of aseptic work and possible sources of their contamination].

    Science.gov (United States)

    Bosković, S; Lucić, N; Aganović, N; Grbić, E

    1975-01-01

    In premises for blood conservation, production of dry human plasma and infusion solutions "notwithstanding the permanent measures for desinfection, new bacterial contamination occurs from time to time and whose source are the casings and material originating from non-sterile environment. Bacteriological control, which has primarily a preventive character, enables a due forecast for measures to be undertaken by the appropriate desinfection of the working surfaces and air, satisfactory conditions of aseptic work can be maintained. General hygiene should be paid attention to as well as mechanical cleansing of premises, avoidance of groups for lunch-time etc., since the treatment by desinfectors would not be sufficient for maintenance of aseptic working conditions. In order to prevent the transmission of bacterial contamination, premises for blood conservation should be strictly separated from other operations and also prevent the unnecessary movements of personnel through corridors. The results of the bacteriological control of the personnel show that greater attention should be paid to their health care since the workers there work in closed aseptic systems and thus avoid them as a bacteria transmittors in respect to danger of blood and dry human plasma contamination. It is also necessary to efficiently educate the personnel for work in aseptic conditions and also increase their elementary knowledge from bacteriology and hygiene. The bacterial skin-flora on the spot of donor's venepuncture also presents a certain danger for blood contamination. Therefore, it is necessary to establish the most optimal manner of skin desinfecate together with the most appropriate means having a fast bactericidal and fungicidal action. It would also be useful, on the basis of further test, to suggest certain standard for an allowed number of conditionally pathogenic and saprophytic microorganisms which would be used by the instutions performing the blood transfusion and production of

  6. Vacuum infusion equipment design and the influence of reinforcement layers addition to the resin infusion time

    Science.gov (United States)

    Saputra, A. H.; Setyarso, G.

    2016-11-01

    The characteristic of composite material is greatly influenced by the manufacture method of composite. The conventional method that has been used such as hand lay-up and spray up are simple and easy to apply but the composite tend to have a void in it because of the air trapped during the manufacture process. Vacuum infusion is one of the modern composite manufacture process which can replace the conventional method. The problem of this method happens when the resin infusion time become longer due to the addition of reinforcement layers. When the resin infusion time is longer than the resin's gel time, the resin will become gel and not able to flow into the mold. In order to overcome this problem, a study that observe the influence of reinforcement layers addition to the resin infusion time is needed. In this study, vacuum infusion equipment for composite materials manufacturing process that are designed consists of: 1×1m glass as the mold, 1L PVC tube for the resin container, 1L glass tube for the resin trap, and ‘A HP vacuum pump with 7 CFM vacuum speed. The resin that is used in this study is unsaturated polyester resin (UPR) and the fiber used as reinforcement is fiber glass. It is observed that the more number of reinforcement layers the longer resin infusion time will be. The resin infusion time (in seconds) from two until six layers respectively for the area of 15×20cm are: 88, 115, 145, 174, 196; for the area of 15×25cm are: 119, 142, 168, 198, 235; and for the area of 15×35cm are: 181, 203, 235, 263, 303. The maximum reinforcement layers that can be accommodated for each 15×20cm, 15×25cm, and 15×35cm area are respectively 31 layers, 29 layers, and 25 layers.

  7. Analysis on Remote Control of Fire Hydrant Pump%消火栓泵远程控制分析

    Institute of Scientific and Technical Information of China (English)

    鞠永健

    2014-01-01

    分析多幢建筑物合用消火栓泵房的原因和存在的问题,结合工程案例分析计算多幢建筑远程控制消火栓泵的线路压降和消防控制室启停、信号反馈等问题,对现有标准图集中的控制电路图进行修改以解决线路安全和线路压降的矛盾,并对修改后的控制电路图使用注意事项进行说明。%Control circuit diagrams given in the current standard collective drawings are modified to solve the contradictions of line safety and line drop. In addition, precautions for utilization of the modified control circuit diagrams are also given. Modification of the current standard collective drawings is based on the analysis of reasons and problems of shared fire hydrant pump rooms of multiple buildings, on the analysis and calculations via incorporating engineering cases of line drop due to remote control of fire hydrant pumps of multiple buildings , and on the analysis of such issues of start / stop and signal feedback of fire fighting control room.

  8. Blood autotransfusion outcomes compared with Ringer lactate infusion in dogs with hemorrhagic shock induced by controlled bleeding.

    Science.gov (United States)

    Safaei, Mansour; Takami, Hassan Mousavi

    2011-10-01

    The most common cause of shock in the surgical or trauma patient is hemorrhage. Crystalloid solutions and blood transfusion are the mainstays of treatment of hemorrhagic shock. Considering the disadvantages of allogeneic blood transfusion, such as risk of transmission of infectious diseases, and access and maintenance limitations, treatment of shock with autologous blood seems to be a decent solution. Autologous blood accumulated in body cavities in traumatic bleeding (such hemothorax), and bloodshed in operation field during open heart or vascular surgeries, and similar situations, can be utilized again. In this study, autotransfusion effects compared with crystalloid fluid in the treatment of hemorrhagic shock was investigated. After induction of hemorrhagic shock in dogs by Wiggers type controlled bleeding, treating them in a group with autologous blood and another group with Ringer lactate were performed, and the results of treatment were studied. There was no mortality in both treatment approaches. Immediately after treatment, crystalloid positive effects such as renormalized vital signs and appropriate consciousness were more noticeable than autotransfusion, while twenty-four hours after, the desired effects of autologous blood were more pronounced like decreased metabolic acidosis and improvement of diuresis. Crystalloid during the first hours after treatment of hemorrhagic shock may be better than autologous blood as preferred treatment, while autotransfusion showed its benefits some hours after. This finding can be used to develop better strategies for treatment of hemorrhagic shock.

  9. Effect of Target Controlled Infusion of Remifentanil Combined with Sufentanil on Stress Reaction and Postoperative Pain of Elderly Patients in Perioperative Period

    Directory of Open Access Journals (Sweden)

    Naser Babaee

    2016-06-01

    Full Text Available Objective: To explore the effect of target controlled infusion (TCI of remifentanil combined with sufentanil on the stress reaction and postoperative pain of elderly patients in perioperative period.Methods: Ninety-four patients receiving general anesthesia who underwent upper abdominal operation selectively were collected and randomly assigned into observation group (n=47 and control group (n=47. The patients in control group were given remifentanil 5 ng/mL for anesthesia induction and 4 ng/mL for anesthesia maintenance. Patient-controlled intravenous analgesia (PCIA was conducted at the time of suture. The patients in observation group were given remifentanil and sufentanil 2 ng/mL for anesthesia induction and maintenance. PCIA was performed at the time of suture. Systolic blood pressure (SBP, diastolic blood pressure (DBP and heart rate (HR of patients in two groups were compared respectively before anesthesia (T1, before intubation (T2, 1 min after intubation (T3, 1 min after laparotomy (T4 and 1 min after extubation (T5. The violent fluctuation times of intraoperative hemodynamics were closely observed. The levels of serum cortisol and glucose before operation, during operation, 12 h and 24 h after operation, visual analogue scale (VAS scores and doses of analgesics at different postoperative time points were also recorded.Results: Both SBP and DBP at different time points as well as HR at T3 and T4 were significantly lower in observation group than in control group, and the difference was shown statistically significance (P<0.05 or P<0.01. The violent fluctuation times of intraoperative hemodynamics were (2.7±1.2 in observation group and (3.9±1.7 in control group, and the difference was shown statistically significance (t=3.954, P<0.001. The levels of serum cortisol and glucose, VAS scores and doses of analgesics were all significantly lower in observation group than in control group at different postoperative time points, and there was

  10. Safety of Continuous Infusion Ketorolac in Postoperative Coronary Artery Bypass Graft Surgery Patients

    Directory of Open Access Journals (Sweden)

    Meredith L. Howard

    2016-06-01

    Full Text Available Background:Continuous infusion ketorolac is sometimes utilized for analgesia in postoperative coronary artery bypass graft (CABG patients despite contraindications for use. Limited literature surrounds this topic; therefore, this study was conducted to evaluate the safety of this practice. Methods: This retrospective cohort study evaluated the primary outcome of mortality and secondary outcomes of incidence of bleeding and myocardial infarction (MI. All patients who underwent isolated CABG surgeries and received continuous infusion ketorolac during the study period were included. An equal number of randomly selected isolated CABG patients served as control patients. Electronic medical records and the Society of Thoracic Surgeons (STS database were utilized to determine baseline characteristics and outcomes; Results: One hundred and seventy-eight patients met inclusion; 89 in each group. More patients in the control group underwent on-pump surgeries (78.6% vs. 29.2%, p = 0.01 and had higher STS risk scores (1.1% vs. 0.6%, p = 0.003. There was no difference in mortality between the ketorolac group and control group (2.2% vs. 3.3%, p = 0.605. Additionally, no patients experienced a MI and there was no difference in bleeding incidence (5.5% vs. 6.7%, p = 0.58; Conclusions: No association was found between continuous infusion ketorolac and increased risk of mortality, MI, or bleeding events in postoperative CABG patients. Considerations to differences in baseline characteristics must be made when interpreting results.

  11. Use of insulin pump therapy in children and adolescents with type 1 diabetes and its impact on metabolic control: comparison of results from three large, transatlantic paediatric registries.

    Science.gov (United States)

    Sherr, Jennifer L; Hermann, Julia M; Campbell, Fiona; Foster, Nicole C; Hofer, Sabine E; Allgrove, Jeremy; Maahs, David M; Kapellen, Thomas M; Holman, Naomi; Tamborlane, William V; Holl, Reinhard W; Beck, Roy W; Warner, Justin T

    2016-01-01

    While the use of insulin pumps in paediatrics has expanded dramatically, there is still considerable variability among countries in the use of pump technology. The present study sought to describe differences in metabolic control and pump use in young people with type 1 diabetes using data collected in three multicentre registries. Data for the years 2011 and 2012 from 54,410 children and adolescents were collected from the Prospective Diabetes Follow-up Registry (DPV; n = 26,198), T1D Exchange (T1DX; n = 13,755) and the National Paediatric Diabetes Audit (NPDA; n = 14,457). The modality of insulin delivery, based on age, sex and ethnic minority status, and the impact of pump use on HbA1c levels were compared. The overall mean HbA1c level was higher in the NPDA (8.9 ± 1.6% [74 ± 17.5 mmol/mol]) than in the DPV (8.0 ± 1.6% [64 ± 17.0 mmol/mol], p pump use was much lower in the NPDA (14%) than in the DPV (41%, p pump use was associated with a lower mean HbA1c (pump: 8.0 ± 1.2% [64 ± 13.3 mmol/mol] vs injection: 8.5 ± 1.7% [69 ± 18.7 mmol/mol], p pump (p pump less often compared with girls (p insulin pump therapy.

  12. Anestesia venosa total com infusão alvo-controlada de remifentanil e propofol para ablação de fibrilação atrial Anestesia venosa total con infusión objeto-controlada de remifentanil y propofol para ablación de la fibrilación atrial Total intravenous anesthesia with target-controlled infusion of remifetanil and propofol for ablation of atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Fernando Squeff Nora

    2009-12-01

    choice of anesthesia, monitors, and anesthesiologic care for this procedure performed outside the surgical center has not been described. The objective of this report was to describe an anesthesia technique for ablation of AF. CASE REPORT: This is a 49-year old female weighing 73 kg, 155 cm, and ASA II due to hypertension. The patient was monitored with a 12-lead ECG, pulse oximetry, heart rate, bispectral electroencephalography for BIS measurement, suppression rate (SR, and SEF95, and mean arterial pressure (MAP. Intravenous target-controlled infusion (TCI of propofol with a target of 4 µg.mL-1, intravenous TCI of remifentanil with a target of 3 ng.mL-1, and intravenous bolus of rocuronium 0.2 mg.kg-1 were used for induction of anesthesia. The pharmacokinetic model of propofol described by Marsh was used and incorporated into the propofol PFS pump®. The pharmacokinetic model of remifentanil described by Minto was incorporated into the Alaris PK® infusion pump. Local effector, or biophase, concentrations corresponded to the information obtained from the infusion pumps and represented predictive measurements of the concentrations of both drugs on their sites of action. The concentrations of propofol and remifentanil were regulated according to BIS and MAP, respectively. CONCLUSIONS: Total intravenous anesthesia for ablation of AF can be a safe option considering the lack of electrophysiological changes in accessory pathways. The literature on this subject is scarce and new publications could justify, or not, this type of anesthesia during ablation of AF.

  13. [Analgesic effect of transcutaneous electrical acupoint stimulation combined with target-controlled infusion in general anesthesia and effects on cardiovascular system].

    Science.gov (United States)

    He, Bi-mei; Yang, Bo

    2008-03-01

    To observe analgesic effect of transcutaneous electrical acupoint stimulation combined with target-controlled infusion (TCI) in general anesthesia and effects on cardiovascular system. Sixty selective breast operation patients were randomly divided into a combined group and a TCI group, 30 cases in each group. The combined group received anesthesic induction for 30 min with transcutaneous electrical acupoint stimulation and then TCI into vein for general anesthesia, and the transcutaneous electrical acupoint stimulation was continued till the end of the operation. The TCI group only received TCI irito vein for general anesthesia. The target-controlled concentration of the general anesthesia drugs in plasma was monitored to evaluate the analgesic effect of transcutaneous electrical acupoint stimulation. Meanwhile, the effects of the transcutaneous electrical acupoint stimulation on cardiovascular system were investigated. The mean Propofol and Fentany dosages needed were 226.67 mg and 0.11 mg in the combined group, and 272.22 mg and 0.14 mg in the TCI group during the operation, respectively, with significant differences (P < 0.05 or P < 0.01). The changes of heart rate and blood pressure in the combined group during skin-cutting were significantly less than those in the TCI group (P < 0.05). The awaking time in the combined group was significantly shortened. The transcutaneous electrical acupoint stimulation has a certain analgesic effect in the operation and can reduce 17% Propofol dosage and 14% Fentany dosage, and it can decrease the skin-cutting-induced stress reaction of the cardiovascular system and accelerate waking.

  14. The fluid control mechanism of bionic structural heterogeneous composite materials and its potential application in enhancing pump efficiency

    Directory of Open Access Journals (Sweden)

    Limei Tian

    2015-11-01

    Full Text Available Studies have shown that the structure of dolphin skin controls fluid media dynamically. Gaining inspiration from this phenomenon, a kind of bionic structural heterogeneous composite material was designed. The bionic structural heterogeneous composite material is composed of two materials: a rigid metal base layer with bionic structures and an elastic polymer surface layer with the corresponding mirror structures. The fluid control mechanism of the bionic structural heterogeneous composite material was investigated using a fluid–solid interaction method in ANSYS Workbench. The results indicated that the bionic structural heterogeneous composite material’s fluid control mechanism is its elastic deformation, which is caused by the coupling action between the elastic surface material and the bionic structure. This deformation can decrease the velocity gradient of the fluid boundary layer through changing the fluid–solid actual contact surface and reduce the frictional force. The bionic structural heterogeneous composite material can also absorb some energy through elastic deformation and avoid energy loss. The bionic structural heterogeneous composite material was applied to the impeller of a centrifugal pump in a contrast experiment, increasing the pump efficiency by 5% without changing the hydraulic model of the impeller. The development of this bionic structural heterogeneous composite material will be straightforward from an engineering point of view, and it will have valuable practical applications.

  15. [Insulin pump therapy: for whom and why?].

    Science.gov (United States)

    Saraheimo, Markku; Honkasalo, Mikko; Miettinen, Marko

    2013-01-01

    Insulin pump therapy utilizes continuous infusion for the basic supply of insulin. As compared with multiple daily injections, pump therapy enables a clearly more precise targeting of the insulin therapy with respect to both time and quantity. This is important for insulin-sensitive patients such as small children, adults susceptible to hypoglycemia, or diabetics, whose blood glucose level exhibits a clear-cut elevation in the small hours (the dawn phenomenon). Also a diabetic with a high HbA1c and a good motivation for treatment may significantly benefit from the pump. Insulin pump therapy requires commitment to good self-monitoring from the diabetic patient.

  16. AUTOMATIC CONTROL SYSTEM FOR THE HEAT PUMP EMBEDDED IN THE MILK PASTEURIZATION AND COOLING INSTALLATION, part II

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2013-04-01

    Full Text Available The goal of the present work is to elaborate the scheme of the disturbance compensation system, which is influencing the level of refrigerant consumption in evaporators and gas coolers of the heat pump embedded in the milk pasteurization and cooling installation, as well as, to design the automatic control system for the heat-exchanger with two output parameters – the water temperature at the outlet of the primary and secondary heat-carrying agent circuits by adjusting the consumption level in the secondary heat-carrying agent circuit and by adjusting the heat exchange surface area. System structures are based on principles of the coordinated control and the multidimensional systems control. The proposed structural scheme of the coordinated system for control of the consumption in evaporators, both water heating and cooling segments, is more accurate in transient processes than alternative systems of non-integrated control of the working agent consumption in each evaporator. The heat exchanger control system with two controls controlling segments (controlling the heat exchange surface area and controlling the consumption level in the secondary coolant circuit has proven to have good transient characteristics.

  17. Use of proton pump inhibitors and the risk of listeriosis. A nationwide registry-based case-control study

    DEFF Research Database (Denmark)

    Kvistholm Jensen, Anne; Simonsen, Jacob; Ethelberg, Steen

    2017-01-01

    BACKGROUND: Recent studies suggest that proton pump inhibitors (PPIs) may increase the risk for listeriosis. We aimed to investigate a potential association in cases of non-pregnancy associated listeriosis, using registry data. METHODS: We conducted a population-based case-control study using...... Danish health registries. Case-patients (n=721) were defined as patients ≥45 years notified with listeriosis, July 1994 to December 2012. We selected 34,800 control-subjects by risk-set sampling. Controls were individually matched for age, sex, municipality and time. Person data on use of PPI and other...... conditional logistic regression, matched odds ratios (ORs) adjusted for CMI and confounders were estimated. RESULTS: The adjusted OR with current use of PPIs for development of listeriosis was 2.81 (95% confidence interval [CI], 2.14-3.69). PPI usage up to 90 days before the index date remained statistically...

  18. Pump-shaped dump optimal control reveals the nuclear reaction pathway of isomerization of a photoexcited cyanine dye.

    Science.gov (United States)

    Dietzek, Benjamin; Brüggemann, Ben; Pascher, Torbjörn; Yartsev, Arkady

    2007-10-31

    Using optimal control as a spectroscopic tool we decipher the details of the molecular dynamics of the essential multidimensional excited-state photoisomerization - a fundamental chemical reaction of key importance in biology. Two distinct nuclear motions are identified in addition to the overall bond-twisting motion: Initially, the reaction is dominated by motion perpendicular to the torsion coordinate. At later times, a second optically active vibration drives the system along the reaction path to the bottom of the excited-state potential. The time scales of the wavepacket motion on a different part of the excited-state potential are detailed by pump-shaped dump optimal control. This technique offers new means to control a chemical reaction far from the Franck-Condon point of absorption and to map details of excited-state reaction pathways revealing unique insights into the underlying reaction mechanism.

  19. Magnetocaloric pump

    Science.gov (United States)

    Brown, G. V.

    1973-01-01

    Very cold liquids and gases such as helium, neon, and nitrogen can be pumped by using magnetocaloric effect. Adiabatic magnetization and demagnetization are used to alternately heat and cool slug of pumped fluid contained in closed chamber.

  20. Effect of perioperative insulin infusion on surgical morbidity and mortality

    DEFF Research Database (Denmark)

    Gandhi, Gunjan Y; Murad, M Hassan; Flynn, Errol David;

    2008-01-01

    To conduct a systematic review and meta-analysis of randomized controlled trials (RCTs) to evaluate the effect of perioperative insulin infusion on outcomes important to patients.......To conduct a systematic review and meta-analysis of randomized controlled trials (RCTs) to evaluate the effect of perioperative insulin infusion on outcomes important to patients....

  1. Continuous intraperitoneal insulin infusion in the treatment of type 1 diabetes mellitus : glycaemia and beyond

    NARCIS (Netherlands)

    van Dijk, Peter R.

    2015-01-01

    Continuous intraperitoneal insulin infusion (CIPII) with an implantable pump is a last-resort treatment option for selected patients with type 1 diabetes mellitus (T1DM). As compared to the most commonly used forms of insulin administration -injections and an externally placed pump- which deliver in

  2. Continuous intraperitoneal insulin infusion in the treatment of type 1 diabetes mellitus : glycaemia and beyond

    NARCIS (Netherlands)

    van Dijk, Peter R.

    2015-01-01

    Continuous intraperitoneal insulin infusion (CIPII) with an implantable pump is a last-resort treatment option for selected patients with type 1 diabetes mellitus (T1DM). As compared to the most commonly used forms of insulin administration -injections and an externally placed pump- which deliver

  3. Crystallization Analysis and Control of Ammonia-Based Air Source Absorption Heat Pump in Cold Regions

    Directory of Open Access Journals (Sweden)

    Wei Wu

    2013-01-01

    Full Text Available Energy consumption of heating and domestic hot water is very high and will keep increasing. Air source absorption heat pump (ASAHP was proposed to overcome the problems of low energy efficiency and high air pollution existing in boiler systems, as well as the problem of bad performance under low ambient temperatures for electrical heat pumps. In order to investigate the crystallization possibility of ammonia-salt ASAHP, crystallization margin (evaluated by solution mass concentration at generating temperature ranging from 100 to 150°C, evaporating temperature from −30 to 10°C, and condensing temperature from 30 to 65°C are analyzed. To prevent the NH3–NaSCN solution from crystallizing, ASAHP integrated with pressure booster located between the evaporator and absorber is simulated. Analysis and comparisons show that NH3–NaSCN is easy to crystallize at relatively high generating temperature, low evaporating temperature, and low condensing temperature. But crystallization margin of NH3–LiNO3 can always stay above 5% for most conditions, keeping away from crystallization. Pressure booster can effectively avoid the crystallization problem that will take place in the NH3–NaSCN ASAHP system.

  4. Performance of a closed-loop feedback computer-controlled infusion system for maintaining blood pressure during spinal anaesthesia for caesarean section: a randomized controlled comparison of norepinephrine versus phenylephrine.

    Science.gov (United States)

    Ngan Kee, Warwick D; Khaw, Kim S; Tam, Yuk-Ho; Ng, Floria F; Lee, Shara W

    2017-06-01

    Closed-loop feedback computer-controlled vasopressor infusion has been previously described for maintaining blood pressure during spinal anaesthesia for caesarean section but there are limited data available comparing the relative performance of different vasopressors. The aim of this study was to compare the performance of norepinephrine versus phenylephrine in this system. Data from a randomized, two-arm parallel group, double-blinded controlled trial were reanalyzed. 104 patients scheduled for elective caesarean section under spinal anaesthesia were randomized to receive computer-controlled closed-loop infusion of either norepinephrine 5 µg ml(-1) or phenylephrine 100 µg ml(-1). This was started immediately after induction of spinal anaesthesia and used an algorithm designed to maintain systolic blood pressure near baseline until fetal delivery. Performance error calculations were used to compare the performance of the two vasopressors. The primary outcome was defined as the median absolute performance error. Median performance error, wobble and divergence were also compared. Median absolute performance error was smaller in the norepinephrine group (median 3.79 [interquartile range 2.82-5.17] %) versus the phenylephrine group (4.70 [3.23-6.57] %, P = 0.028). In addition, median performance error was smaller (0.75 [-1.56-2.52] %) versus 2.61 [0.83-4.57] %, P = 0.002) and wobble was smaller (2.85 [2.07-5.17] %) versus 3.39 [2.62-4.90] %, P = 0.028) in the norepinephrine group versus the phenylephrine group. Divergence was similar between groups. The precision of the control of blood pressure was greater with norepinephrine compared with phenylephrine at the drug concentrations used.

  5. IMITATING THE MODEL OF THE FREQUENCY CONVERTER - INDUCTION MOTOR OF A PUMP WATER SYSTEM WITH ADAPTIVE CONTROL ALGORITHM

    Directory of Open Access Journals (Sweden)

    Taranov D. M.

    2015-06-01

    Full Text Available This article presents main water supply systems and justifies the choice of direct flow of water supply system in the application of regulation of electric drive for pumps, which doesn’t have any tanks to create pressures required for fire-governmental purposes. This avoids interruption in the supply of reserve while water freezing. In the article the substantiation of the necessity of implementation of adaptive algorithm in modern-WIDE frequency converters by a substantiation of the number of stages of ratio control of voltage-frequency mains. It was revealed that the number of degrees of regulation of 10-12 gives optimum. Modern frequency converters allow you to change the regulation law, establishing 3-5 points of regulation. Therefore, the introduction of adaptive algorithm will reduce the power consumption of the electric drive of the pump of the water supply system. The article shows the simulation model of the "the converter frequency-induction motor," plots of the stator current of mains frequency and active power, surface speed and phase current when changing the voltage and frequency of the mains. These dependences confirm to have applicability of adaptive algorithm in the regulation of modern frequency converters with the skalar administration. Simulation model confirms the sub-physical experiments on a real motor and frequency converter with adaptive control algorithm. As a result of the selection of the parameters, we obtain the voltage reduction of the phase current, and reduce electricity consumption by 5-7%

  6. Modeling and Controlling Flow Transient in Pipeline Systems: Applied for Reservoir and Pump Systems Combined with Simple Surge Tank

    Directory of Open Access Journals (Sweden)

    Itissam ABUIZIAH

    2014-03-01

    Full Text Available When transient conditions (water hammer exist, the life expectancy of the system can be adversely impacted, resulting in pump and valve failures and catastrophic pipe rupture. Hence, transient control has become an essential requirement for ensuring safe operation of water pipeline systems. To protect the pipeline systems from transient effects, an accurate analysis and suitable protection devices should be used. This paper presents the problem of modeling and simulation of transient phenomena in hydraulic systems based on the characteristics method. Also, it provides the influence of using the protection devices to control the adverse effects due to excessive and low pressure occuring in the transient. We applied this model for two main pipeline systems: Valve and pump combined with a simple surge tank connected to reservoir. The results obtained by using this model indicate that the model is an efficient tool for water hammer analysis. Moreover, using a simple surge tank reduces the unfavorable effects of transients by reducing pressure fluctuations.

  7. Comparison of the hemodynamic response to induction and intubation during a target-controlled infusion of propofol with 2 different pharmacokinetic models. A prospective ramdomized trial.

    Science.gov (United States)

    Ramos Luengo, A; Asensio Merino, F; Castilla, M S; Alonso Rodriguez, E

    2015-11-01

    Determine the best propofol pharmacokinetic model that meets patient requirements and is devoid of major haemodynamic side effects. Prospective, randomised, open-label, clinical trial was performed on an intention to treat basis. It included 280 patients with ASA physical status i-iii, aged 18 to 80 years and weight range between 45 to 100kg, scheduled for surgery under general anaesthesia. They were randomized into 2 groups according to the pharmacokinetic model: Modified Marsh group and Schnider group. The haemodynamic changes that occurred during the induction and intubation were analysed. A propofol target controlled infusion was started to achieve and maintain a bispectral index value between 35 and 55. At minute 6, orotracheal intubation was performed and the study finished at minute 11. Heart rate, mean arterial pressure and their product (HR×MAP) were measured and recorded every minute throughout the study. Every HR×MAP value was compared to its baseline value to determine the minimum value before intubation, the maximum value after intubation, the maximum variation after intubation, and its final value. The GRADIENTE (MIN, MAX) variable (primary endpoint of this study) analyses the difference between maximal and minimal values related to intubation. Propofol doses and calculated concentrations and any hypotensive events were also recorded. No differences were found between groups regarding haemodynamic performance. GRADIENTE (MIN, MAX) values and the percentage of hypotensive events were: Modified Marsh group median 77.41% vs. Schnider group 84.86% (p= 0.821) and 17.3% vs. 12.8% (p = 0.292), respectively. The study failed to demonstrate any haemodynamic difference between the 2 groups, even though the Modified Marsh group received a larger dose of propofol. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. [Guidelines concerning insulin dosage in children and adolescents with type 1 diabetes on continuous subcutaneous insulin infusion].

    Science.gov (United States)

    Szypowska, Agnieszka; Pańkowska, Ewa; Lipka, Maria

    2006-01-01

    The treatment of diabetes mellitus with a continuous subcutaneous insulin infusion (CSII) has become very popular and is well accepted by diabetic patients. Pump therapy mimics the physiological insulin secretion and has been shown to be a safe and effective method of insulin administration alternative to the method of multiple injections. Continuous insulin infusion provides greater flexibility in the timing of meals and snacks with higher treatment satisfaction. Programmed basal rates improve nocturnal glycemic control and help to minimize a pre-breakfast increase of blood glucose level (the dawn phenomenon). Moreover, CSII can reduce exercise-induced and nocturnal hypoglycemia. Insulin pump therapy is effective in lowering glycated hemoglobin levels without higher risk of severe hypoglycaemia and ketoacidosis. To achieve a proper metabolic control with this method of treatment, the patient and his family requires appropriate education including knowledge of diet management, insulin therapy and manual competence of pump device. Here we present general guidelines for patients education concerning insulin dosage, programming of basal insulin rates and meal boluses based on carbohydrates and protein-fat exchanges.

  9. Direct effects of TNF-α on local fuel metabolism and cytokine levels in the placebo controlled bilaterally infused human leg; increased insulin sensitivity, increased net protein breakdown and increased IL-6 release

    DEFF Research Database (Denmark)

    Bach, Ermina; Nielsen, Bent Roni Ranghøj; Vendelbo, Mikkel H;

    2013-01-01

    Tumor necrosis factor-α (TNF-α) has widespread metabolic actions. Systemic TNF-α administration, however, generates a complex hormonal and metabolic response. Our study was designed to test whether regional, placebo-controlled TNF-α infusion directly affects insulin resistance and protein breakdo...... interest and may concurrently act to provide adequate tissue fuel supply and contribute to the occurrence of systemic hypoglycemia. This distinct metabolic feature places TNF-α among the rare insulin mimetics of human origin....

  10. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  11. Improved Glycemic Control With Intraperitoneal Versus Subcutaneous Insulin in Type 1 Diabetes A randomized controlled trial

    NARCIS (Netherlands)

    Logtenberg, Susan J.; Kleefstra, Nanne; Houweling, Sebastiaan T.; Groenier, Klaas H.; Gans, Reinold O.; van Ballegooie, Evert; Bilo, Henk J.

    2009-01-01

    OBJECTIVE - Continuous intraperitoneal insulin infusion (CIPII) with an implantable pump has been available for the past 25 years. CIPII, with its specific pharmacodynamic properties, may be a viable treatment alternative to improve glycemic control in patients with type I diabetes for whom other th

  12. Improved Glycemic Control With Intraperitoneal Versus Subcutaneous Insulin in Type 1 Diabetes A randomized controlled trial

    NARCIS (Netherlands)

    Logtenberg, Susan J.; Kleefstra, Nanne; Houweling, Sebastiaan T.; Groenier, Klaas H.; Gans, Reinold O.; van Ballegooie, Evert; Bilo, Henk J.

    OBJECTIVE - Continuous intraperitoneal insulin infusion (CIPII) with an implantable pump has been available for the past 25 years. CIPII, with its specific pharmacodynamic properties, may be a viable treatment alternative to improve glycemic control in patients with type I diabetes for whom other

  13. Effects of target-controlled infusion of high-dose naloxone on pain and hyperalgesia in a human thermal injury model: a study protocol: A randomized, double-blind, placebo-controlled, crossover trial with an enriched design.

    Science.gov (United States)

    Springborg, Anders D; Jensen, Elisabeth K; Taylor, Bradley K; Werner, Mads U

    2016-11-01

    Mu-opioid-receptor antagonists have been extensively studied in experimental research as pharmacological tools uncovering mechanisms of pain modulation by the endogenous opioid system. In rodents, administration of high doses of mu-opioid-receptor antagonists after the resolution of an inflammatory injury has demonstrated reinstatement of nociceptive hypersensitivity indicating unmasking of latent sensitization. In a recent human study, pain hypersensitivity assessed as secondary hyperalgesia area (SHA), was reinstated 7 days after a mild thermal injury, in 4 out of 12 subjects after a naloxone infusion.The aims of the present study are first, to replicate our previous findings in a larger-sized study; second, to examine if high sensitizers (subjects presenting with large SHA after a thermal injury) develop a higher degree of hypersensitivity after naloxone challenge than low sensitizers (subjects presenting with restricted SHA after a thermal injury); and third to examine a dose-response relationship between 3 stable naloxone concentrations controlled by target-controlled infusion, and the unmasking of latent sensitization.Healthy participants (n = 80) underwent a screening day (day 0) with induction of a thermal skin injury (47°C, 420 seconds, 12.5 cm). Assessment of SHA was performed 1 and 2 hours after the injury. Using an enriched design, only participants belonging to the upper quartile of SHA (Q4, high sensitizers; n = 20) and the lower quartile of SHA (Q1, low sensitizers; n = 20) continued the study, comprising 4 consecutive days-days 1 to 4. Thermal skin injuries were repeated on day 1 and day 3, whereas day 2 and day 4 (7 days after day 1 and day 3, respectively) were target-controlled infusion days in which the subjects were randomly allocated to receive either naloxone (3.25 mg/kg, 4 mg/mL) or placebo (normal saline) intravenous. The primary outcome was SHA assessed by weighted-pin instrument (128 mN) 0, 1, 2, and 165 to 169

  14. Relationship between depth of anesthesia and effect-site concentration of propofol during induction with the target-controlled infusion technique in elderly patients

    Institute of Scientific and Technical Information of China (English)

    LILT Shao-hua; WEI Wei; DING Guan-nan; KE Jing-dong; HONG Fang-xiao; TIAN Ming

    2009-01-01

    Background There are few studies to assess whether the effect-site concentration of propofol can predict anesthetic depth during the target-controlled infusion (TCI) induction in eldedy patients. This study aimed to evaluate the relationship between effect-site concentration of propofol and depth of anesthesia during the TCI induction in eldedy patients.Methods Ninety patients (60-80 years) with an American Society of Anesthesiologists (ASA) physical status of 1-3, undergoing scheduled abdominal and thoracic surgery under general anesthesia were randomly allocated into one of three groups, Group S1, S2 and S3 (30 patients in each group). The patients in Group S1 received propofol with a target plasma concentration of 4.0 μg/ml; patients in Group S2 received propofol with an initial target plasma concentrations of 2.0 μg/ml that was raised to 4.0 μg/ml 3 minutes later; patients in Group S3 received an infused scheme of 3 steps; starting from a target plasma concentration of 2.0 μg/ml that was increased stepwised by 1 μg/ml until a target plasma concentration of 4.0 μg/ml was achieved, the interval between the two steps was 3 minutes. When an Observer's Assessment of Alertness/Sedation (OAA/S) score of 1 was achieved, remifentanil (effect-site concentration (Ce) of 4.0 ng/ml) and rocuronium 0.9 mg/kg were administered. Tracheal intubation was started 2 minutes after rocuronium injection. Changes of propofol Ce, blood pressure (BP), heart rate (HR), and bispectral index (BIS) were recorded. Results When an OAA/S score of 1 was achieved, Ce of propofol were (1.7±0.4) μg/ml, (1.9±0.3) μg/ml, (1.9±0.4) μg/ml and the BIS values were 64±5, 65±8, and 62±8 in Groups S1, S2 and S3. Before intubation, Ce of propofol was (2.8±0.2) μg/ml, (2.8±0.3) μg/ml, (2.7±0.3) μg/ml, and the BIS values were 48±7, 51±7, and 47±5 in Groups S1, S2 and S3. By linear regression analysis, a significant correlation between Ce of propofol and BIS values was found (r=-0

  15. Performance Evaluation of HP/ORC (Heat Pump/Organic Rankine Cycle) System with Optimal Control of Sensible Thermal Storage

    DEFF Research Database (Denmark)

    Do Carmo, Carolina Madeira Ramos; Nielsen, Mads Pagh; Elmegaard, Brian

    2016-01-01

    energy in periods of no thermal energy demand and reverses the heat pump cycle to supply electrical power. A dynamic model based on empirical data of this system is used to determine the annual performance. Furthermore, this work assesses the benefits of different control strategies that address...... of the users. Results show that real load control logic can lessen the adverse effects of cycling in the compressor of the system as well as increase the thermal demand (up to 33%) and the electrical demand (max. 8.4%) covered by renewable energy (solar). However, the extension of these improvements is highly......In energy systems with high share of renewable energy sources, like wind and solar power, it is paramount to deal with their intrinsic variability. The interaction between electric and thermal energy (heating and cooling) demands represent a potential area for balancing supply and demand that could...

  16. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  17. Nutritional education and carbohydrate counting in children with type 1 diabetes treated with continuous subcutaneous insulin infusion: the effects on dietary habits, body composition and glycometabolic control.

    Science.gov (United States)

    Marigliano, Marco; Morandi, Anita; Maschio, Maddalena; Sabbion, Alberto; Contreas, Giovanna; Tomasselli, Francesca; Tommasi, Mara; Maffeis, Claudio

    2013-12-01

    Carbohydrate counting (CHC) in combination with nutritional education has been used to optimize the insulin dose in patients with type 1 diabetes (T1D). The aim of this study was to test the impact of CHC and nutritional education on changes in dietary habits, body composition and body fat distribution in children with T1D treated with insulin pumps (CSII). Twenty-five children with T1D and CSII were recruited and valuated at baseline and after 18 months of follow-up. They were trained in CHC and following standard nutrition education program (based on American Diabetes Association and International Society of Pediatric and Adolescent Diabetes guidelines); clinical, biochemical and nutritional variables were measured. In the total population, body composition, body fat distribution and biochemical variables did not change, at follow-up; HbA1c was significantly reduced (8.50 ± 0.77 vs 7.92 ± 0.74 %; p nutritional education, does not affect dietary habits, body composition and body fat distribution in children with T1D treated with CSII. Moreover, the sub-group of subjects showing a significant improvement in glycometabolic control reported an increase in CHO intake and a reduction in fat and protein intake.

  18. Exploring novel infusion regimens of phenylephrine during spinal anesthesia for caesarean delivery: The effects on hemodynamic control and fetal acid-base status

    Directory of Open Access Journals (Sweden)

    Syed N Muzaffar

    2016-01-01

    Materials and Methods: Ninety parturients undergoing SA for elective caesarean delivery received an IV infusion of phenylephrine in one of three different concentration ratios. The groups contained a potency equivalent of 100 μg/min, 80μg/min, and 60 μg/min infusion doses. The infusions were adjusted to maintain systolic blood pressure (SBP near the baseline until uterine incision. Hemodynamic changes in mother and umbilical cord blood gases were compared. Results: As concentration of phenylephrine increased, following significant trends were noticed: in group A, 10/29 (34.5% patients had hypotension as compared to 2/28 (7.4% patients in group B and 4/28 (14.3% patients in group C. On the other hand, we found that the incidence of hypertension and bradycardia was higher in groups B (22/28; 4/28 and C (26/28; 10/28 as compared to those in group A (3/29; 2/29, respectively. Neonatal acid-base status in all three groups was favorable. Conclusions: As the concentration of phenylephrine increased, the tendency for SBP to be above the baseline increased, along with an incidence of bradycardia. Therefore, we conclude that low dose infusion regimens of phenylephrine, i.e. between 60 μg/min and 80 μg/min, will be more effective in prevention of hypotension during SA for caesarean delivery.

  19. The plumbing of the global biological pump: Efficiency control through leaks, pathways, and time scales

    Science.gov (United States)

    Pasquier, Benoît; Holzer, Mark

    2016-08-01

    We systematically quantify the pathways and time scales that set the efficiency, Ebio, of the global biological pump by applying Green-function-based diagnostics to a data-assimilated phosphorus cycle embedded in a jointly assimilated ocean circulation. We consider "bio pipes" that consist of phosphorus paths that connect specified regions of last biological utilization with regions where regenerated phosphate first reemerges into the euphotic zone. The bio pipes that contribute most to Ebio connect the Eastern Equatorial Pacific (EEqP) and Equatorial Atlantic to the Southern Ocean ((21 ± 3)% of Ebio), as well as the Southern Ocean to itself ((15 ± 3)% of Ebio). The bio pipes with the largest phosphorus flow rates connect the EEqP to itself and the subantarctic Southern Ocean to itself. The global mean sequestration time of the biological pump is 130 ± 70 years, while the sequestration time of the bio pipe from anywhere to the Antarctic region of the Southern Ocean is 430 ± 30 years. The distribution of phosphorus flowing within a given bio pipe is quantified by its transit-time partitioned path density. For the largest bio pipes, ˜1/7 of their phosphorus is carried by thermocline paths with transit times less than ˜300-400 years, while ˜4/7 of their phosphorus is carried by abyssal paths with transit times exceeding ˜700 years. The path density reveals that Antarctic Intermediate Water carries about a third of the regenerated phosphate last utilized in the EEqP that is destined for the Southern Ocean euphotic zone. The Southern Ocean is where (62 ± 2)% of the regenerated inventory and (69 ± 1)% of the preformed inventory first reemerge into the euphotic zone.

  20. Hydrodynamic Effects on Modeling and Control of a High Temperature Active Magnetic Bearing Pump with a Canned Rotor

    Energy Technology Data Exchange (ETDEWEB)

    Melin, Alexander M [ORNL; Kisner, Roger A [ORNL; Fugate, David L [ORNL; Holcomb, David Eugene [ORNL

    2015-01-01

    Embedding instrumentation and control Embedding instrumentation and control (I\\&C) at the component level in nuclear power plants can improve component performance, lifetime, and resilience by optimizing operation, reducing the constraints on physical design, and providing on-board prognostics and diagnostics. However, the extreme environments that many nuclear power plant components operate in makes embedding instrumentation and control at the component level difficult. Successfully utilizing embedded I\\&C requires developing a deep understanding of the system's dynamics and using that knowledge to overcome material and physical limitations imposed by the environment. In this paper, we will develop a coupled dynamic model of a high temperature (700 $^\\circ$C) canned rotor pump that incorporates rotordynamics, hydrodynamics, and active magnetic bearing dynamics. Then we will compare two control design methods, one that uses a simplified decoupled model of the system and another that utilizes the full coupled system model. It will be seen that utilizing all the available knowledge of the system dynamics in the controller design yield an order of magnitude improvement in the magnitude of the magnetic bearing response to disturbances at the same level of control effort, a large reduction in the settling time of the system, and a smoother control action.