WorldWideScience

Sample records for control tracheal tube

  1. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    Science.gov (United States)

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  2. 21 CFR 868.5795 - Tracheal tube cleaning brush.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheal tube cleaning brush. 868.5795 Section 868.5795 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5795 Tracheal tube cleaning brush. (a...

  3. A visual stethoscope to detect the position of the tracheal tube.

    Science.gov (United States)

    Kato, Hiromi; Suzuki, Akira; Nakajima, Yoshiki; Makino, Hiroshi; Sanjo, Yoshimitsu; Nakai, Takayoshi; Shiraishi, Yoshito; Katoh, Takasumi; Sato, Shigehito

    2009-12-01

    Advancing a tracheal tube into the bronchus produces unilateral breath sounds. We created a Visual Stethoscope that allows real-time fast Fourier transformation of the sound signal and 3-dimensional (frequency-amplitude-time) color rendering of the results on a personal computer with simultaneous processing of 2 individual sound signals. The aim of this study was to evaluate whether the Visual Stethoscope can detect bronchial intubation in comparison with auscultation. After induction of general anesthesia, the trachea was intubated with a tracheal tube. The distance from the incisors to the carina was measured using a fiberoptic bronchoscope. While the anesthesiologist advanced the tracheal tube from the trachea to the bronchus, another anesthesiologist auscultated breath sounds to detect changes of the breath sounds and/or disappearance of bilateral breath sounds for every 1 cm that the tracheal tube was advanced. Two precordial stethoscopes placed at the left and right sides of the chest were used to record breath sounds simultaneously. Subsequently, at a later date, we randomly entered the recorded breath sounds into the Visual Stethoscope. The same anesthesiologist observed the visualized breath sounds on the personal computer screen processed by the Visual Stethoscope to examine changes of breath sounds and/or disappearance of bilateral breath sound. We compared the decision made based on auscultation with that made based on the results of the visualized breath sounds using the Visual Stethoscope. Thirty patients were enrolled in the study. When irregular breath sounds were auscultated, the tip of the tracheal tube was located at 0.6 +/- 1.2 cm on the bronchial side of the carina. Using the Visual Stethoscope, when there were any changes of the shape of the visualized breath sound, the tube was located at 0.4 +/- 0.8 cm on the tracheal side of the carina (P Stethoscope (not significant). During advancement of the tracheal tube, alterations of the shape of the

  4. Use of the silicone tracheal T-tube for tracheostenosis or tracheomalacia.

    Science.gov (United States)

    Liu, H C; Wang, L S; Fahn, H J; Lee, Y C; Lu, C C; Chan, K H; Huang, M H

    1996-09-01

    Tracheobtenosib and tracheomalacia are trivial diseases. The conventional choice of managements with tracheostomy, either temporary or long-term usage, can only partially resolve the problems of airway obstruction. Silicone tracheal T-tube presents a substitute for it. We present 5 patients with tracheostenosis or tracheomalacia managed with nine procedures of long silicone Montgomery T-tube prothesis between 1984 and 1994 in VGH-Taipei. The primary diagnosis included tracheal injury (2), postintubation tracheal stenosis (2), and stenosis due to endotracheal tuberculosis (1). Three patients received a long segmental T-tube for permanent endotracheal stenting and the other two patients used T-tube insertion for temporary stenting of the trachea for 7 and 11 months, respectively, with satisfactory results. All patients got immediate benefit from the prothesis in respiration with simple postoperative care. Two patients with temporary T-tube placement had it successfully removed in 7 and 11 months, respectively. Placement of the T-tube for subglottic stenosis also protected the function of phonation. The tracheal T-tube restored airway patency reliably with good long-term results and could be the preferred management of chronic upper airway obstructive disease not amenable to surgical repair. The most common complication was airway obstruction caused by either granulations or sticky mucoid substance. Three patients and six tubes (60%) developed granulation obstruction and the average duration of granuloma formation was 7.7 months. Laser phototherapy or surgical intervention, such as tracheoplasty, with change of the T-tube was carried out for granuloma obstruction. T-tube is a good endoprothesis for tracheostenosis and tracheomalacia with minimal complication for cases of long tracheostenosis or complex tracheal injury.

  5. Drosophila convoluted/dALS is an essential gene required for tracheal tube morphogenesis and apical matrix organization.

    Science.gov (United States)

    Swanson, Lianna E; Yu, Marcus; Nelson, Kevin S; Laprise, Patrick; Tepass, Ulrich; Beitel, Greg J

    2009-04-01

    Insulin-like growth factors (IGFs) control cell and organism growth through evolutionarily conserved signaling pathways. The mammalian acid-labile subunit (ALS) is a secreted protein that complexes with IGFs to modulate their activity. Recent work has shown that a Drosophila homolog of ALS, dALS, can also complex with and modulate the activity of a Drosophila IGF. Here we report the first mutations in the gene encoding dALS. Unexpectedly, we find that these mutations are allelic to a previously described mutation in convoluted (conv), a gene required for epithelial morphogenesis. In conv mutants, the tubes of the Drosophila tracheal system become abnormally elongated without altering tracheal cell number. conv null mutations cause larval lethality, but do not disrupt several processes required for tracheal tube size control, including septate junction formation, deposition of a lumenal/apical extracellular matrix, and lumenal secretion of Vermiform and Serpentine, two putative matrix-modifying proteins. Clearance of lumenal matrix and subcellular localization of clathrin also appear normal in conv mutants. However, we show that Conv/dALS is required for the dynamic organization of the transient lumenal matrix and normal structure of the cuticle that lines the tracheal lumen. These and other data suggest that the Conv/dALS-dependent tube size control mechanism is distinct from other known processes involved in tracheal tube size regulation. Moreover, we present evidence indicating that Conv/dALS has a novel, IGF-signaling independent function in tracheal morphogenesis.

  6. Difficulty with cuff deflation of reinforced tracheal tube caused by inflation line occlusion with silk thread ligation and fixation.

    Science.gov (United States)

    Gotoh, Sayoko; Sugiyama, Daisuke; Imai, Eriko; Kawamata, Mikito

    2015-03-05

    A reinforced tracheal tube, ligated with silk threads, was inserted into a tracheostomy orifice and fixed to the skin. The cuff inflation line of the reinforced tracheal tube became occluded. Reinforced 'armoured' tracheal tubes have a spiral of wire embedded into the wall of the tube to give strength and flexibility, and may be sharply bent without compromising the tube lumen. The tracheal cuff attached to the tube is inflated by injecting air through a narrow-diameter tube welded to the outside of the tracheal tube. When a reinforced tracheal tube is ligated and fixed with silk threads, it should be confirmed whether the tracheal tube cuff can be deflated and inflated after fixation. Moreover, because occlusion can be eliminated by removing all silk threads used to ligate a tracheal tube, they should be removed before extubation. 2015 BMJ Publishing Group Ltd.

  7. Tracheal tube and laryngeal mask cuff pressure during anaesthesia - mandatory monitoring is in need

    DEFF Research Database (Denmark)

    Rokamp, K.Z.; Secher, N.H.; Møller, Ann

    2010-01-01

    ABSTRACT: BACKGROUND: To prevent endothelium and nerve lesions, tracheal tube and laryngeal mask cuff pressure is to be maintained at a low level and yet be high enough to secure air sealing. METHOD: In a prospective quality-control study, 201 patients undergoing surgery during anaesthesia (without...... the use of nitrous oxide) were included for determination of the cuff pressure of the tracheal tubes and laryngeal masks. RESULTS: In the 119 patients provided with a tracheal tube, the median cuff pressure was 30 (range 8 - 100) cm H2O and the pressure exceeded 30 cm H2O (upper recommended level) for 54...... patients. In the 82 patients provided with a laryngeal mask, the cuff pressure was 95 (10 - 121) cm H2O and above 60 cm H2O (upper recommended level) for 56 patients and in 34 of these patients, the pressure exceeded the upper cuff gauge limit (120 cm H2O). There was no association between cuff pressure...

  8. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation.

    Science.gov (United States)

    Chou, Hao-Chang; Chong, Kah-Meng; Sim, Shyh-Shyong; Ma, Matthew Huei-Ming; Liu, Shih-Hung; Chen, Nai-Chuan; Wu, Meng-Che; Fu, Chia-Ming; Wang, Chih-Hung; Lee, Chien-Chang; Lien, Wan-Ching; Chen, Shyr-Chyr

    2013-12-01

    This study aimed to evaluate the accuracy of tracheal ultrasonography for assessing endotracheal tube position during cardiopulmonary resuscitation (CPR). We performed a prospective observational study of patients undergoing emergency intubation during CPR. Real-time tracheal ultrasonography was performed during the intubation with the transducer placed transversely just above the suprasternal notch, to assess for endotracheal tube positioning and exclude esophageal intubation. The position of trachea was identified by a hyperechoic air-mucosa (A-M) interface with posterior reverberation artifact (comet-tail artifact). The endotracheal tube position was defined as endotracheal if single A-M interface with comet-tail artifact was observed. Endotracheal tube position was defined as intraesophageal if a second A-M interface appeared, suggesting a false second airway (double tract sign). The gold standard of correct endotracheal intubation was the combination of clinical auscultation and quantitative waveform capnography. The main outcome was the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR. Among the 89 patients enrolled, 7 (7.8%) had esophageal intubations. The sensitivity, specificity, positive predictive value, and negative predictive value of tracheal ultrasonography were 100% (95% confidence interval [CI]: 94.4-100%), 85.7% (95% CI: 42.0-99.2%), 98.8% (95% CI: 92.5-99.0%) and 100% (95% CI: 54.7-100%), respectively. Positive and negative likelihood ratios were 7.0 (95% CI: 1.1-43.0) and 0.0, respectively. Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during CPR without the need for interruption of chest compression. Tracheal ultrasonography in resuscitation management may serve as a powerful adjunct in trained hands. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Middle finger length-based tracheal intubation depth improves the rate of appropriate tube placement in children.

    Science.gov (United States)

    Zhou, Qing-he; Xiao, Wang-pin; Zhou, Hong-mei

    2015-11-01

    It is challenging for anesthetists to determine the optimal tracheal intubation depth in children. We hypothesize that a measure three times the length of the middle finger can be used for predicting tracheal tube depth in children. Eighty-six children (4-14 years of age) were included in this study. After the children were anesthetized, a fiberoptic bronchoscope (FOB) was inserted into the trachea, the lengths from the upper incisor teeth to carina and vocal cords were measured, and a suitably sized cuffed tracheal tube was inserted into the trachea. Age-based and middle finger length-based formulas were used to determine the tracheal intubation depth. All 86 children enrolled were included in this study. Compared with the age-based intubation, the rate of appropriate tube placement was higher for middle finger length-based intubation (88.37% vs 66.28%, P = 0.001). The proximal intubation rate was lower in middle finger length-based intubation (4.65% vs 32.56%, P tube depth was larger than that between age and optimal tracheal tube depth (0.883 vs 0.845). Our data indicate that the appropriate tube placement rate can be improved by using three times the middle finger length as the tracheal intubation depth in children. © 2015 John Wiley & Sons Ltd.

  10. Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.

    Science.gov (United States)

    Kumar, R D C; Hirsch, N P

    2011-11-01

    Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  11. Comparison of Effectiveness of Betamethasone gel Applied to the Tracheal Tube and IV Dexamethasone on Postoperative Sore Throat: A Randomized Controlled Trial.

    Science.gov (United States)

    Tabari, Masumeh; Soltani, Ghasem; Zirak, Nahid; Alipour, Moammad; Khazaeni, Kamran

    2013-09-01

    Postoperative sore throat is a common complaint in patients with endotracheal intubation and has potentially dangerous complications. This randomized controlled trial study investigated the incidence of postoperative sore throat after general anesthesia when betamethasone gel is applied to a tracheal tube compared with when IV dexamethasone is prescribed. Two hundred and twenty five American Society of Anesthesiologist (ASA)-class I and II patients undergoing elective abdominal surgery with tracheal intubation were randomly divided into three groups: betamethasone gel, intravenous (IV) dexamethasone, and control groups. In the post-anesthesia care unit, a blinded anesthesiologist interviewed all patients regarding postoperative sore throat at 1,6, and 24 hours after surgery. The incidence of sore throat was significantly lower in the betamethasone gel group compared with the IV dexamethasone and control groups, 1, 6, and 24 hours after surgery. In the first day after surgery 10.7% of the betamethasone group had sore throat whereas 26.7% of the IV dexamethasone group and 30.7% of the control group had sore throat. Bucking before extubation was observed in 14(18.4%), 8(10.4%), and 9(12.2%) patients, in the IV dexamethasone, betamethasone gel, and control group, respectively. We concluded that wide spread application of betamethasone gel over tracheal tubes effectively mitigates postoperative sore throat, compared with IV dexamethasone application.

  12. Comparison of Effectiveness of Betamethasone gel Applied to the Tracheal Tube and IV Dexamethasone on Postoperative sore Throat: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Masoomeh Tabari

    2013-10-01

    Full Text Available Introduction: Postoperative sore throat is a common complaint in patients with endotracheal intubation and has potentially dangerous complications. This randomized controlled trial study investigated the incidence of postoperative sore throat after general anesthesia when betamethasone gel is applied to a tracheal tube compared with when IV dexamethasone is prescribed.   Materials and Methods: Two hundred and twenty five American Society of Anesthesiologist (ASA-class I and II patients undergoing elective abdominal surgery with tracheal intubation were randomly divided into three groups: betamethasone gel, intravenous (IV dexamethasone, and control groups. In the post-anesthesia care unit, a blinded anesthesiologist interviewed all patients regarding postoperative sore throat at 1,6, and 24 hours after surgery.   Results: The incidence of sore throat was significantly lower in the betamethasone gel group compared with the IV dexamethasone and control groups, 1, 6, and 24 hours after surgery. In the first day after surgery 10.7% of the betamethasone group had sore throat whereas 26.7% of the IV dexamethasone group and 30.7% of the control group had sore throat. Bucking before extubation was observed in 14(18.4%, 8(10.4%, and 9(12.2% patients, in the IV dexamethasone, betamethasone gel, and control group, respectively.   Conclusion:  We concluded that wide spread application of betamethasone gel over tracheal tubes effectively mitigates postoperative sore throat, compared with IV dexamethasone application.

  13. Tracheal palpation to assess endotracheal tube depth: an exploratory study.

    Science.gov (United States)

    McKay, William P; Klonarakis, Jim; Pelivanov, Vladko; O'Brien, Jennifer M; Plewes, Chris

    2014-03-01

    Correct placement of the endotracheal tube (ETT) occurs when the distal tip is in mid-trachea. This study compares two techniques used to place the ETT at the correct depth during intubation: tracheal palpation vs placement at a fixed depth at the patient's teeth. With approval of the Research Ethics Board, we recruited American Society of Anesthesiologists physical status I-II patients scheduled for elective surgery with tracheal intubation. Clinicians performing the tracheal intubations were asked to "advance the tube slowly once the tip is through the cords". An investigator palpated the patient's trachea with three fingers spread over the trachea from the larynx to the sternal notch. When the ETT tip was felt in the sternal notch, the ETT was immobilized and its position was determined by fibreoptic bronchoscopy. The position of the ETT tip was compared with our hospital standard, which is a depth at the incisors or gums of 23 cm for men and 21 cm for women. The primary outcome was the incidence of correct placement. Correct placement of the ETT was defined as a tip > 2.5 cm from the carina and > 3.5 cm below the vocal cords. Movement of the ETT tip was readily palpable in 77 of 92 patients studied, and bronchoscopy was performed in 85 patients. Placement by tracheal palpation resulted in more correct placements (71 [77%]; 95% confidence interval [CI] 74 to 81) than hospital standard depth at the incisors or gums (57 [61%]; 95% CI 58 to 66) (P = 0.037). The mean (SD) placement of the ETT tip in palpable subjects was 4.1 (1.7) cm above the carina, 1.9 cm (1.5-2.3 cm) below the ideal mid-tracheal position. Tracheal palpation requires no special equipment, takes only a few seconds to perform, and may improve ETT placement at the correct depth. Further studies are warranted.

  14. [Use of the Pentax-AWS videolaryngoscope for bougie-assisted exchange of tracheal tubes].

    Science.gov (United States)

    Kishii, Miki; Asai, Takashi; Nagata, Atsushi; Shingu, Koh

    2009-06-01

    A gum elastic bougie can be useful for tube exchange. One major problem with this technique is that it may not possible to pass a new tube over the bougie into the trachea, because the tip of the tube can collide with tissues around the glottis. We report a case in which tube exchange using the bougie was difficult, but the Pentax-AWS videolaryngoscope enabled tracheal intubation. In a 62-year-old trauma patient with head and neck stabilized using a Halo vest, was scheduled for emergency fixation of the neck. Exchange of a polyvinylchloride tube to a reinforced tube was planned. A bougie was passed through the old tube, removing the tube, and a new tube was advanced over the bougie, but it was impossible to advance the tube into the trachea. Insertion of a Macintosh laryngoscope did not enable intubation. The new tube was removed from the bougie, attached to the Pentax-AWS videolaryngoscope, and the tube (with the Pentax-AWS) was passed over the bougie. Although it was not possible to see the glottis with the Pentax-AWS, the tube was easily advanced over the bougie into the trachea. Operation went on uneventfully. We believe that, when it is difficult to advance a tracheal tube over a tube exchanger, the use of the Pentax-AWS may facilitate intubation.

  15. Cuff depth and continuous chest auscultation method for determination of tracheal tube insertion depth in nasal intubation: observational study.

    Science.gov (United States)

    Ouchi, Kentaro; Sugiyama, Kazuna

    2016-04-01

    Incorrect endobronchial placement of the tracheal tube can lead to serious complications. Hence, it is necessary to determine the accuracy of tracheal tube positioning. Markers are included on tracheal tubes, in the process of their manufacture, as indicators of approximate intubation depth. In addition, continuous chest auscultation has been used for determining the proper position of the tube. We examined insertion depth using the cuff depth and continuous chest auscultation method (CC method), compared with insertion depth determined by the marker method, to assess the accuracy of these methods. After induction of anesthesia, tracheal intubation was performed in each patient. In the CC method, the depth of tube insertion was measured when the cuff had passed through the glottis, and again when breath sounds changed in quality; the depth of tube insertion was determined from these values. In the marker method, the depth of tube insertion was measured and determined when the marker of the tube had reached the glottis, using insertion depth according to the marker as an index. Insertion depth by the marker method was 26.6 ± 1.2 cm and by the CC method was 28.0 ± 1.2 cm (P < 0.0001). The CC method indicated a significantly greater depth than the marker method. This study determined the safe range of tracheal tube placement. Tube positions determined by the CC method were about 1 cm deeper than those determined by the marker. This information is important to prevent accidental one-lung ventilation and accidental extubation. UMIN No. UMIN000011375.

  16. Engineered cartilaginous tubes for tracheal tissue replacement via self-assembly and fusion of human mesenchymal stem cell constructs.

    Science.gov (United States)

    Dikina, Anna D; Strobel, Hannah A; Lai, Bradley P; Rolle, Marsha W; Alsberg, Eben

    2015-06-01

    There is a critical need to engineer a neotrachea because currently there are no long-term treatments for tracheal stenoses affecting large portions of the airway. In this work, a modular tracheal tissue replacement strategy was developed. High-cell density, scaffold-free human mesenchymal stem cell-derived cartilaginous rings and tubes were successfully generated through employment of custom designed culture wells and a ring-to-tube assembly system. Furthermore, incorporation of transforming growth factor-β1-delivering gelatin microspheres into the engineered tissues enhanced chondrogenesis with regard to tissue size and matrix production and distribution in the ring- and tube-shaped constructs, as well as luminal rigidity of the tubes. Importantly, all engineered tissues had similar or improved biomechanical properties compared to rat tracheas, which suggests they could be transplanted into a small animal model for airway defects. The modular, bottom up approach used to grow stem cell-based cartilaginous tubes in this report is a promising platform to engineer complex organs (e.g., trachea), with control over tissue size and geometry, and has the potential to be used to generate autologous tissue implants for human clinical applications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Strategies to prevent ventilation-associated pneumonia: the effect of cuff pressure monitoring techniques and tracheal tube type on aspiration of subglottic secretions: an in-vitro study.

    Science.gov (United States)

    Carter, Eleanor L; Duguid, Alasdair; Ercole, Ari; Matta, Basil; Burnstein, Rowan M; Veenith, Tonny

    2014-03-01

    Ventilation-associated pneumonia (VAP) is the commonest nosocomial infection in intensive care. Implementation of a VAP prevention care bundle is a proven method to reduce its incidence. The UK care bundle recommends maintenance of the tracheal tube cuff pressure at 20 to 30  cmH₂O with 4-hourly pressure checks and use of tracheal tubes with subglottic aspiration ports in patients admitted for more than 72  h. To evaluate the effects of tracheal tube type and cuff pressure monitoring technique on leakage of subglottic secretions past the tracheal tube cuff. Bench-top study. Laboratory. A model adult trachea with simulated subglottic secretions was intubated with a tracheal tube with the cuff inflated to 25  cmH₂O. Experiments were conducted using a Portex Profile Soft Seal tracheal tube with three cuff pressure monitoring strategies and using a Portex SACETT tracheal tube with intermittent cuff pressure checks. Rate of simulated secretion leakage past the tracheal tube cuff. Mean ± SD leakage of fluid past the Profile Soft Seal tracheal tube cuff was 2.25 ± 1.49  ml  min⁻¹ with no monitoring of cuff pressure, 2.98 ± 1.63  ml  min⁻¹ with intermittent cuff pressure monitoring and 3.83 ± 2.17  ml  min⁻¹ with continuous cuff pressure monitoring (P aspiration port and aspirating the simulated secretions prior to intermittent cuff pressure checks reduced the leakage rate to 0.50 ± 0.48  ml  min⁻¹ (P aspiration port. Further evaluation of medical device performance is needed in order to design more effective VAP prevention strategies.

  18. Management of dogs and cats with endotracheal tube tracheal foreign bodies

    Science.gov (United States)

    Nutt, Laura K.; Webb, Jinelle A.; Prosser, Kirsten J.; Defarges, Alice

    2014-01-01

    Two cats and 3 dogs were treated for an endotracheal tube tracheal foreign body (ETFB) during recovery from general anesthesia. Bronchoscopy was used to remove the ETFB. Animals were clinically normal at discharge. While rare, ETFB can occur upon recovery from anesthesia. Bronchoscopy is an effective way to remove ETFB. PMID:24891640

  19. Complete subglottic tracheal stenosis managed with rigid bronchoscopy and T-tube placement

    Directory of Open Access Journals (Sweden)

    Kuruswamy Thurai Prasad

    2016-01-01

    Full Text Available Surgery is the preferred treatment modality for benign tracheal stenosis. Interventional bronchoscopy is used as a bridge to surgery or in instances when surgery is not feasible or has failed. Stenosis in the subglottic trachea is particularly a treatment challenge, in view of its proximity to the vocal cords. Herein, we describe a patient with complete tracheal stenosis in the subglottic region, which developed after prolonged intubation and mechanical ventilation. The patient developed recurrent stenosis despite multiple surgical and endoscopic procedures. We were able to manage the patient successfully with rigid bronchoscopy and Montgomery T-tube placement.

  20. Management of Benign Tracheal Stenosis by Small-diameter Tube-assisted Bronchoscopic Balloon Dilatation

    Directory of Open Access Journals (Sweden)

    Yi-Lin Liang

    2015-01-01

    Full Text Available Background: A limitation of bronchoscopic balloon dilatation (BBD is that airflow must be completely blocked for as long as possible during the operation. However, the patient often cannot hold his or her breath for a long period affecting the efficacy of the procedure. In this study, we used an extra-small-diameter tube to provide assisted ventilation to patients undergoing BBD and assessed the efficacy and safety of this technique. Methods: Bronchoscopic balloon dilatation was performed in 26 patients with benign tracheal stenosis using an extra-small-diameter tube. The tracheal diameter, dyspnea index, blood gas analysis results, and complications were evaluated before and after BBD. Statistical analyses were performed by SPSS version 16.0 for Windows (SPSS, Inc., Chicago, IL, USA. Results: Sixty-three BBD procedures were performed in 26 patients. Dyspnea immediately improved in all patients after BBD. The tracheal diameter significantly increased from 5.5 ± 1.5 mm to 13.0 ± 1.3 mm (P < 0.001, and the dyspnea index significantly decreased from 3.4 ± 0.8 to 0.5 ± 0.6 (P < 0.001. There was no significant change in the partial pressure of oxygen during the operation (before, 102.5 ± 27.5 mmHg; during, 96.9 ± 30.4 mmHg; and after, 97.2 ± 21.5 mmHg; P = 0.364, but there was slight temporary retention of carbon dioxide during the operation (before, 43.5 ± 4.2 mmHg; during, 49.4 ± 6.8 mmHg; and after, 40.1 ± 3.9 mmHg; P < 0.001. Conclusion: Small-diameter tube-assisted BBD is an effective and safe method for the management of benign tracheal stenosis.

  1. Subcellular trafficking of FGF controls tracheal invasion of Drosophila flight muscle.

    Science.gov (United States)

    Peterson, Soren J; Krasnow, Mark A

    2015-01-15

    To meet the extreme oxygen demand of insect flight muscle, tracheal (respiratory) tubes ramify not only on its surface, as in other tissues, but also within T-tubules and ultimately surrounding every mitochondrion. Although this remarkable physiological specialization has long been recognized, its cellular and molecular basis is unknown. Here, we show that Drosophila tracheoles invade flight muscle T-tubules through transient surface openings. Like other tracheal branching events, invasion requires the Branchless FGF pathway. However, localization of the FGF chemoattractant changes from all muscle membranes to T-tubules as invasion begins. Core regulators of epithelial basolateral membrane identity localize to T-tubules, and knockdown of AP-1γ, required for basolateral trafficking, redirects FGF from T-tubules to surface, increasing tracheal surface ramification and preventing invasion. We propose that tracheal invasion is controlled by an AP-1-dependent switch in FGF trafficking. Thus, subcellular targeting of a chemoattractant can direct outgrowth to specific domains, including inside the cell. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Tracheal stoma necrosis: a case repor

    Directory of Open Access Journals (Sweden)

    Pak S

    2017-04-01

    Full Text Available Acute tracheal dilatation, due to an overinflated cuff, has been reported early in the course of mechanical ventilation through an endotracheal tube. Tracheal stoma necrosis is a rare complication, but such can accompany acute tracheal dilation. Herein, we report a case of tracheal necrosis 9 days following tracheostomy placement in a 71-year old woman associated with overinflation of the tracheal tube cuff. This case report aims to 1 add to the scant body of knowledge about the diagnosis and management for the patients with tracheal stoma necrosis and 2 raise awareness for error-traps in interpreting diagnostic images, specifically satisfaction of search error, inattentional blindness error, and alliterative error.

  3. Long-term outcome of conventional endotracheal tube balloon dilation of tracheal stenosis in a dog

    OpenAIRE

    Kahane, Nili; Segev, Gilad

    2014-01-01

    This report describes a successful dilation of tracheal stenosis in a 16-year-old dog using a conventional endotracheal tube balloon. This technique should be considered as palliative treatment when owners decline other therapeutic options.

  4. Long-term outcome of conventional endotracheal tube balloon dilation of tracheal stenosis in a dog.

    Science.gov (United States)

    Kahane, Nili; Segev, Gilad

    2014-01-01

    This report describes a successful dilation of tracheal stenosis in a 16-year-old dog using a conventional endotracheal tube balloon. This technique should be considered as palliative treatment when owners decline other therapeutic options.

  5. Variation in the mechanical properties of tracheal tubes in the American cockroach

    International Nuclear Information System (INIS)

    Becker, Winston R; Webster, Matthew R; De Vita, Raffaella; Socha, John J

    2014-01-01

    The insect cuticle serves the protective role of skin and the supportive role of the skeleton while being lightweight and flexible to facilitate flight. The smart design of the cuticle confers camouflage, thermo-regulation, communication, self-cleaning, and anti-wetting properties to insects. The mechanical behavior of the internal cuticle of the insect in tracheae remains largely unexplored due to their small size. In order to characterize the material properties of insect tracheae and understand their role during insect respiration, we conducted tensile tests on ring sections of tracheal tubes of American cockroaches (Periplaneta americana). A total of 33 ring specimens collected from 14 tracheae from the upper thorax of the insects were successfully tested. The ultimate tensile strength (22.6 ± 13.3 MPa), ultimate strain (1.57 ± 0.68%), elastic modulus (1740 ± 840 MPa), and toughness (0.175 ± 0.156 MJ m −3 ) were measured. We examined the high variance in mechanical properties statistically and demonstrated that ring sections excised from the same trachea exhibit comparable mechanical properties. Our results will form the basis for future studies aimed at determining the structure–function relationship of insect tracheal tubes, ultimately inspiring the design of multi-functional materials and structures. (technical note)

  6. Laryngoscope and a new tracheal tube assist lightwand intubation in difficult airways due to unstable cervical spine.

    Directory of Open Access Journals (Sweden)

    Cai-neng Wu

    Full Text Available The WEI Jet Endotracheal Tube (WEI JET is a new tracheal tube that facilitates both oxygenation and ventilation during the process of intubation and assists tracheal intubation in patients with difficult airway. We evaluated the effectiveness and usefulness of the WEI JET in combination with lightwand under direct laryngoscopy in difficult tracheal intubation due to unstable cervical spine.Ninety patients with unstable cervical spine disorders (ASA I-III with general anaesthesia were included and randomly assigned to three groups, based on the device used for intubation: lightwand only, lightwand under direct laryngoscopy, lightwand with WEI JET under direct laryngoscopy.No statistically significant differences were detected among three groups with respect to demographic characteristics and C/L grade. There were statistically significant differences between three groups for overall intubation success rate (p = 0.015 and first attempt success rate (p = 0.000. The intubation time was significantly longer in the WEI group (110.8±18.3 s than in the LW group (63.3±27.5 s, p = 0.000 and DL group (66.7±29.4 s, p = 0.000, but the lowest SpO2 in WEI group was significantly higher than other two groups (p<0.01. The WEI JET significantly reduced successful tracheal intubation attempts compared to the LW group (p = 0.043. The severity of sore throat was similar in three groups (p = 0.185.The combined use of WEI JET under direct laryngoscopy helps to assist tracheal intubation and improves oxygenation during intubation in patients with difficult airway secondary to unstable spine disorders.Chinese Clinical Trial Registry ChiCTR-TRC-14005141.

  7. Comparison between traditional and small-diameter tube-assisted bronchoscopic balloon dilatation in the treatment of benign tracheal stenosis.

    Science.gov (United States)

    Li, Li-Hua; Liang, Yi-Lin; Li, Yu; Xu, Ming-Peng; Li, Wen-Tao; Liu, Guang-Nan

    2018-03-01

    To compare the safety and efficacy between using a small-diameter tube-assisted bronchoscopic balloon dilatation (BBD) and the traditional BBD in the treatment of benign tracheal stenosis. A retrospective study included 58 patients with benign tracheal stenosis from August 2009 to December 2014 was made. The patients who underwent traditional BBD were divided into group A, and who underwent a small-diameter tube-assisted BBD were divided into group B. The tracheal diameter, dyspnea index and blood gas analysis results were detected before and after BBD. Efficacy and complications were evaluated after BBD. There were significant differences in oxygen saturation (PaO 2 ) during the operations comparing with before and after operations in group A (P = .005), while there was no significant difference in group B (P = .079). The tracheal diameter obviously increased (in group A, from 4.16 ± 1.43 mm to 12.47 ± 1.41 mm, P = .000; in group B: from 4.94 ± 1.59 mm to 12.61 ± 1.41 mm, P = .000). Dyspnea index obviously decreased (group A: from 3.21 ± 0.93 to 0.50 ± 0.59, P = .000; group B: from 3.24 ± 0.89 to 0.65 ± 0.69, P = .000). The immediately cure rate in both groups was 100%. Long-term effect was significantly better in group B than that in group A (85.3% vs 59.1%, P = .021), at the end of the follow-up period. Small-diameter tube-assisted BBD obtains better safety and long-term efficacy than the traditional BBD in the treatment of benign tracheal stenosis. However, close attention should be given to the risk of the adverse effects caused by carbon dioxide retention. © 2017 John Wiley & Sons Ltd.

  8. Interactions between Type III receptor tyrosine phosphatases and growth factor receptor tyrosine kinases regulate tracheal tube formation in Drosophila

    Directory of Open Access Journals (Sweden)

    Mili Jeon

    2012-04-01

    The respiratory (tracheal system of the Drosophila melanogaster larva is an intricate branched network of air-filled tubes. Its developmental logic is similar in some ways to that of the vertebrate vascular system. We previously described a unique embryonic tracheal tubulogenesis phenotype caused by loss of both of the Type III receptor tyrosine phosphatases (RPTPs, Ptp4E and Ptp10D. In Ptp4E Ptp10D double mutants, the linear tubes in unicellular and terminal tracheal branches are converted into bubble-like cysts that incorporate apical cell surface markers. This tube geometry phenotype is modulated by changes in the activity or expression of the epidermal growth factor receptor (Egfr tyrosine kinase (TK. Ptp10D physically interacts with Egfr. Here we demonstrate that the Ptp4E Ptp10D phenotype is the consequence of the loss of negative regulation by the RPTPs of three growth factor receptor TKs: Egfr, Breathless and Pvr. Reducing the activity of any of the three kinases by tracheal expression of dominant-negative mutants suppresses cyst formation. By competing dominant-negative and constitutively active kinase mutants against each other, we show that the three RTKs have partially interchangeable activities, so that increasing the activity of one kinase can compensate for the effects of reducing the activity of another. This implies that SH2-domain downstream effectors that are required for the phenotype are likely to be able to interact with phosphotyrosine sites on all three receptor TKs. We also show that the phenotype involves increases in signaling through the MAP kinase and Rho GTPase pathways.

  9. Low tracheal tumor and airway management: An anesthetic challenge

    Directory of Open Access Journals (Sweden)

    Richa Saroa

    2015-01-01

    Full Text Available We describe a case presenting with tracheal tumor wherein a Microlaryngeal tube was advanced into the trachea distal to the tumor for primary airway control followed by cannulation of both endobronchial lumen with 5.5 mm endotracheal tubes to provide independent lung ventilation post tracheal transection using Y- connector attached to anesthesia machine. The plan was formulated to provide maximal surgical access to the trachea while providing adequate ventilation at the same time. A 32 yrs non smoker male, complaining of cough, progressive dyspnea and hemoptysis was diagnosed to have a broad based mass in the trachea on computed tomography of chest. Bronchoscopy of the upper airway confirmed presence of the mass at a distance of 9 cms from the vocal cords, obstructing the tracheal lumen by three fourth of the diameter. The patient was scheduled to undergo the resection of the mass through anterolateral thoracotomy. We recommend the use of extralong, soft, small sized microlaryngeal surgery tube in tumors proximal to carina, for securing the airway before the transection of trachea and bilateral endobronchial intubation with small sized cuffed endotracheal tubes for maintenance of ventilation after the transection of trachea in patients with mass in the lower trachea.

  10. Endoscopically placed nitinol stents for pediatric tracheal obstruction.

    Science.gov (United States)

    Prasad, Mukesh; Bent, John P; Ward, Robert F; April, Max M

    2002-11-11

    To provide preliminary clinical data regarding endoscopically placed nitinol stents for children with tracheal obstruction as a temporizing measure to allow for trach tube decannulation while awaiting growth to allow for tracheal resection. This case series describes the experiences of two children (ages 5 and 15) who were dependent upon tracheotomy because of acquired tracheal obstruction. Both patients had combined tracheomalacia and tracheal stenosis. After failing tracheoplasty with rib graft augmentation both patients suffered from extensive tracheal disease, which was too long to allow for immediate tracheal resection. Endoscopic placement of nitinol stents in the obstructed tracheal segment using fluoroscopic guidance. All tracheotomy tubes were removed immediately after successful stent deployment with the patient still under general anesthesia. Four stents were placed in total. The first patient's initial stent was too narrow and was, therefore, removed and replaced at a later date with a larger diameter stent. The second patient experienced distal migration of his initial stent requiring stent removal and replacement at a later date. Both patients remain successfully decannulated (follow-up, 25 and 26 months) and are currently living more normal lives as they grow and await tracheal resection. Preliminary use of nitinol stents for pediatric tracheal obstruction has enabled successful decannulation in two children with complicated airways. Our results with this series of patients suggest that nitinol stents can be safely used in children as a temporizing measure until tracheal resection can be safely performed. With this approach children can live free from the hassles of trach care, social isolation and peer ridicule. Limited pediatric experience exists in the literature about nitinol stents. Thus, our experience with stent selection and placement will help others avoid problems encountered in this initial series. Copyright 2002 Elsevier Science Ireland

  11. Impact of tracheal cuff shape on microaspiration of gastric contents in intubated critically ill patients: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Jaillette, Emmanuelle; Brunin, Guillaume; Girault, Christophe; Zerimech, Farid; Chiche, Arnaud; Broucqsault-Dedrie, Céline; Fayolle, Cyril; Minacori, Franck; Alves, Isabelle; Barrailler, Stephanie; Robriquet, Laurent; Tamion, Fabienne; Delaporte, Emmanuel; Thellier, Damien; Delcourte, Claire; Duhamel, Alain; Nseir, Saad

    2015-09-25

    Ventilator-associated pneumonia (VAP) is the most common infection in intubated critically ill patients. Microaspiration of the contaminated gastric and oropharyngeal secretions is the main mechanism involved in the pathophysiology of VAP. Tracheal cuff plays an important role in stopping the progression of contaminated secretions into the lower respiratory tract. Previous in vitro studies suggested that conical cuff shape might be helpful in improving tracheal sealing. However, clinical studies found conflicting results. The aim of this study is to determine the impact of conical tracheal cuff shape on the microaspiration of gastric contents in critically ill patients. This prospective cluster randomized controlled crossover open-label trial is currently being conducted in ten French intensive care units (ICUs). Patients are allocated to intubation with a polyvinyl chloride (PVC) standard (barrel)-shaped or a PVC conical-shaped tracheal tube. The primary objective is to determine the impact of the conical shaped tracheal cuff on abundant microaspiration of gastric contents. Secondary outcomes include the incidence of microaspiration of oropharyngeal secretions, tracheobronchial colonization, VAP and ventilator-associated events. Abundant microaspiration is defined as the presence of pepsin at significant level (>200 ng/ml) in at least 30 % of the tracheal aspirates. Pepsin and amylase are quantitatively measured in all tracheal aspirates during the 48 h following inclusion. Quantitative tracheal aspirate culture is performed at inclusion and twice weekly. We plan to recruit 312 patients in the participating ICUs. BEST Cuff is the first randomized controlled study evaluating the impact of PVC tracheal-cuff shape on gastric microaspirations in patients receiving invasive mechanical ventilation. Enrollment began in June 2014 and is expected to end in October 2015. ClinicalTrials.gov Identifier: NCT01948635 (registered 31 August 2013).

  12. and Non-Operable Tracheal Stenosis

    Directory of Open Access Journals (Sweden)

    Reza Bagheri

    2013-05-01

    Full Text Available   Introduction: Tracheal stenosis is normally caused by trauma, infection, benign and malignant tumors, prolonged intubation or tracheostomy. The best treatment for tracheal stenosis is resection and anastomosis of trachea. Yet the major surgical complication of tracheal surgery is postoperative stenosis. The goal of this paper is to study the result of tracheal stenting as a replacement therapy for patients suffering from tracheal stenosis who are not good candidates for surgery.   Materials and Methods: This study presents the results of stenting in patients with: Inoperable tumoral stenosis,Non-tumoral stenosis being complicated due to prior surgeries,Inability to undergo a major surgery.The study was performed between September 2002 and July 2011 and poly flex stents were used by means of rigid bronchoscopy. Results: A total of 25 patients received stents during this study. Among them 15 patients suffered from benign and 10 suffered from malignant tracheal stenosis. The patients were followed up for at most 12 months after the stenting operation. The mean age of the patients was 35 years. The most common cause of stenosis was prolonged intubation (75%. The most common indication for stenting was the history of multiple tracheal operations. The most common complication of stenting and cause of stent removal was formation of granulation tissue. 30% of patients with benign tracheal stenosis were cured and about 10% improved until they could stand a major operation. Ten patients in benign group and 2 patients in malignant group (20% needed T-Tube insertion after stent removal but other patientcure by stenting. Conclusions: In benign cases stenting is associated with recurrence of symptoms which requires other therapeutic techniqus, so the stenting may not be named as a final solution in benign cases. However, this technique is the only method with approved efficacy for malignant cases with indication.

  13. Rescue patient from tracheal obstruction by dislocated bronchial stent during tracheostomy surgery with readily available tools: A case report.

    Science.gov (United States)

    Chang, Hung-Yu; Man, Kee-Ming; Liao, Kate Hsiurong; Chiang, Yi-Ying; Chen, Kuen-Bao

    2017-09-01

    Airway stenting is a well-established method that relieves symptoms and maintains airway patency in patients with airway obstruction. Serious complications caused by airway stents such as stent dislocation and airway obstruction during surgery are life-threatening. An 80-year-old man was treated with bronchial stent for left bronchus obstruction caused by metastatic esophageal cancer. During tracheostomy surgery, he suffered from acute tracheal obstruction caused by dislocated bronchial stent. Esophageal cancer, left bronchus obstruction, respiratory failure, tracheal obstruction. Threading a 5.0-sized endotracheal tube combined with an Eschmann tracheal tube introducer to prop up the collapsed stent. The bronchial stent was re-expanded and threaded into right main bronchus and ventilation restored. Patient with airway stent undergoing surgery with airway involved should be performed under the support of a backup physician and equipment that are capable of handling potentially life-threatening complications of airway stent. If not, in the emergent situation of tracheal obstruction due to tracheal/bronchial stent, protruding through the stent with a suitable, small-sized endotracheal tube with Eschmann tracheal tube introducer may be an alternative skill for saving life weighted with possible complications.

  14. Laryngeal morbidity after tracheal intubation

    DEFF Research Database (Denmark)

    Sørensen, M K; Rasmussen, N; Kristensen, M S

    2013-01-01

    BACKGROUND: Tracheal intubation may cause vocal fold damage. The trial was designed to assess laryngeal morbidity comparing the Endoflex(®) tube with a conventional endotracheal tube with stylet. We hypothesised that laryngeal morbidity within the first 24 h after extubation would be lower...... with the Endoflex tube than with the conventional endotracheal tube with stylet because of less rigidity. METHODS: This randomised trial included 130 elective surgical patients scheduled for general anaesthesia with endotracheal intubation. Pre- and post-operative assessment of hoarseness, vocal fold pathology......% with the Endoflex tube and 55% with the endotracheal tube with stylet at 24 h after extubation (P = 0.44). Post-operative vocal fold injury was present in 23% in the Endoflex tube group and in 36% in the endotracheal tube with stylet group (P = 0.13). The increase in shimmer, the voice analysis variable reflecting...

  15. The Role of Tracheal Stenting As an Alternative Treatment in Cicatricial and Non-Operable Tracheal Stenosis

    Directory of Open Access Journals (Sweden)

    Reza Bagheri

    2013-05-01

    Full Text Available Introduction: Tracheal stenosis is normally caused by trauma, infection, benign and malignant tumors, prolonged intubation or tracheostomy. The best treatment for tracheal stenosis is resection and anastomosis of trachea. Yet the major surgical complication of tracheal surgery is postoperative stenosis. The goal of this paper is to study the result of tracheal stenting as a replacement therapy for patients suffering from tracheal stenosis who are not good candidates for surgery. Materials and Methods: This study presents the results of stenting in patients with: Inoperable tumoral stenosis,Non-tumoral stenosis being complicated due to prior surgeries,Inability to undergo a major surgery.The study was performed between September 2002 and July 2011 and poly flex stents were used by means of rigid bronchoscopy. Results: A total of 25 patients received stents during this study. Among them 15 patients suffered from benign and 10 suffered from malignant tracheal stenosis. The patients were followed up for at most 12 months after the stenting operation. The mean age of the patients was 35 years. The most common cause of stenosis was prolonged intubation (75%. The most common indication for stenting was the history of multiple tracheal operations. The most common complication of stenting and cause of stent removal was formation of granulation tissue. 30% of patients with benign tracheal stenosis were cured and about 10% improved until they could stand a major operation. Ten patients in benign group and 2 patients in malignant group (20% needed T-Tube insertion after stent removal but other patientcure by stenting. Conclusions: In benign cases stenting is associated with recurrence of symptoms which requires other therapeutic techniqus, so the stenting may not be named as a final solution in benign cases. However, this technique is the only method with approved efficacy for malignant cases with indication.

  16. Morphological findings in the tracheal epithelium of dogs exposed to the inhalation of poorly conditioned gases under use of an endotracheal tube or laryngeal mask airway.

    Science.gov (United States)

    Dias, Norimar Hernandes; Braz, José Reinaldo Cerqueira; Defaveri, Júlio; Carvalho, Lídia Raquel; Martins, Regina Helena Garcia

    2011-10-01

    To study morphological findings in the tracheal epithelium of dogs exposed to the inhalation of poorly conditioned gases under use of an endotracheal tube (ET) or laryngeal mask airway (LMA). Twelve dogs randomly were allocated to two groups: ET group (n-6) and LMA group (n-6), anaesthetized and mechanically ventilated, without CO(2) reabsorption. Haemodynamic and ventilatory parameters, tympanic temperature, temperature, relative and absolute humidity of the ambient and inhaled gases were analyzed during three hours. The animals were submitted to euthanasia and biopsies were carried out along the tracheal segment to morphological study. Three healthy dogs were used to morphological control. Inhaled gas temperature was maintained between 24ºC and 26ºC, relative humidity between 10% and 12%, and absolute humidity between 2 - 3 mg H(2)O.L(-1) with no significant differences between groups. In both groups, histological analysis showed epithelial inflammation and congestion in the corion and scanning electron microscopy showed ciliary grouping and disorganization. Transmission electron microscopy showed higher alterations in ET group than LMA group as widening of cell junctions, ciliary disorientation, cytoplasmic vacuolization, nuclear abnormalities, picnosis and chromatin condensation. LMA determined less pronounced changes in the tracheal epithelium in dogs exposed to the inhalation of poorly conditioned gases.

  17. Circumferential tracheal resection with primary anastomosis for post-intubation tracheal stenosis: study of 24 cases.

    Science.gov (United States)

    Negm, Hesham; Mosleh, Mohamed; Fathy, Hesham

    2013-09-01

    The objective of this study is to evaluate the results of circumferential tracheal and cricotracheal resection with primary anastomosis for the treatment of post-intubation tracheal and cricotracheal stenosis. This is a retrospective analytical study. A total number of 24 patients were included in this study. The relevant preoperative, operative and postoperative records were collected and analyzed. Twenty patients were finally symptom-free reflecting an anastomosis success rate of 83.3 %. Variable grades of anastomotic restenosis occurred in 11 (45.8 %) patients, three patients were symptom-free and eight had airway obstructive symptoms. Four out of the eight patients with symptomatic restenosis were symptom-free with endoscopic dilatation while the remaining four patients required a permanent airway appliance (T-tube, tracheostomy) for the relief of airway obstruction and this group was considered as anastomotic failure. Cricoid involvement, associated cricoid resection and the type of anastomosis were the variables that had statistical impact on the occurrence of restenosis (P = 0.017, 0.017, 0.05; respectively). Tracheal resection with primary anastomosis is a safe effective treatment method for post-intubation tracheal stenosis in carefully selected patients. Restenosis does not always mean failure of the procedure since it may be successfully managed with endoscopic dilatation.

  18. Saline instillation before tracheal suctioning decreases the incidence of ventilator-associated pneumonia.

    Science.gov (United States)

    Caruso, Pedro; Denari, Silvia; Ruiz, Soraia A L; Demarzo, Sergio E; Deheinzelin, Daniel

    2009-01-01

    To compare the incidence of ventilator-associated pneumonia (VAP) with or without isotonic saline instillation before tracheal suctioning. As a secondary objective, we compared the incidence of endotracheal tube occlusion and atelectasis. Randomized clinical trial. The study was conducted in a medical surgical intensive care unit of an oncologic hospital. We selected consecutive patients needing mechanical ventilation for >72 hrs. Patients were allocated into two groups: a saline group that received instillation of 8 mL of saline before tracheal suctioning and a control group which did not. VAP was diagnosed based on clinical suspicion and confirmed by bronchoalveolar lavage quantitative culture. The incidence of atelectasis on daily chest radiography and endotracheal tube occlusions were recorded. The sample size was calculated to a power of 80% and a type I error probability of 5%. One hundred thirty patients were assigned to the saline group and 132 to the control group. The baseline demographic variables were similar between groups. The rate of clinically suspected VAP was similar in both groups. The incidence of microbiological proven VAP was significantly lower in the saline group (23.5% x 10.8%; p = 0.008) (incidence density/1.000 days of ventilation 21.22 x 9.62; p < 0.01). Using the Kaplan-Meier curve analysis, the proportion of patients remaining without VAP was higher in the saline group (p = 0.02, log-rank test). The relative risk reduction of VAP in the saline instillation group was 54% (95% confidence interval, 18%-74%) and the number needed to treat was eight (95% confidence interval, 5-27). The incidence of atelectases and endotracheal tube occlusion were similar between groups. Instillation of isotonic saline before tracheal suctioning decreases the incidence of microbiological proven VAP.

  19. Securing the airway in a child with tracheal agenesis – an alternative perspective

    Directory of Open Access Journals (Sweden)

    Slavomir Nosal

    2011-03-01

    Full Text Available Tracheal agenesis is an extremely rare, typically fatal congenital anomaly characterised by typical clinical manifestation, failed endotracheal intubation and difficult emergency management. The prognosis and possibility of surgical correction rest on early diagnosis, anatomy, birth weight, and associated anomalies. Tracheal agenesis causes considerable resuscitation difficulties immediately after birth, as tracheal intubation is impossible. Although emergency management, by either bag and mask ventilation or oesophageal intubation, provides some pulmonary gas exchange through tracheo-oesophageal connection, they are associated with overdistension of the stomach and the risk of stomach perforation. We have performed selective intubation of the distal trachea in a child with tracheal agenesis through the tracheo-oesophageal connection with the help of a fibroendoscope. A standard guide wire was passed through the working port of the flexible endoscope and under direct vision was directed through the tracheo-oesophageal connection into the distal trachea. At this point, the endoscope was removed, leaving the guide wire in place. The endotracheal tube size 2 Fr was passed over the guide wire into the distal trachea. The infant showed dramatic improvement and maintained good saturations on mechanical ventilation. The infant was taken for a computed tomography (CT scan, which showed Floyd’s type II tracheal agenesis, the oesophagus connecting with the distal trachea before it bifurcates. The endotracheal tube was seen ending in the carina. Transoesophageal intubation of the short distal segment of the trachea through the tracheo-oesophageal connection might offer a new perspective for short-term securing of the airway in a child with tracheal agenesis and should be considered in any child with suspected tracheal agenesis to buy the time while evaluating the exact anatomy of the anomaly and the possibility of tracheal reconstruction in selected

  20. An evaluation of the retromolar space for oral tracheal tube placement for maxillofacial surgery in children.

    Science.gov (United States)

    Arora, Suman; Rattan, Vidya; Bhardwaj, Neerja

    2006-11-01

    The eruption of the first and second permanent molar teeth may influence the size of the retromolar space. In this study we evaluated the adequacy of the retromolar space for retromolar intubation and any effect of eruption of the first and second permanent molar teeth on this space in children. Children 3-15 yr of age, undergoing surgery other than facial surgery were included for evaluation of the retromolar space. After standard oral tracheal intubation, the endotracheal tube was shifted to the retromolar space and the mandible was slowly closed to achieve centric occlusion. At the same time, any increase in airway resistance or decrease in oxygen saturation was noted. In the second part of the study, the feasibility of retromolar intubation in pediatric patients undergoing maxillofacial surgery with intraoperative maxillomandibular fixation was assessed. There was enough space for endotracheal tube placement in the retromolar region. The eruption of the first and second permanent molar teeth did not affect intubation. It was possible to achieve centric occlusion in 79 of 80 children with the endotracheal tube positioned in the retromolar space. Retromolar intubation was successfully accomplished in six pediatric patients undergoing maxillomandibular fixation and maxillofacial surgery. The retromolar space can be safely used for intubation in children when intraoperative maxillomandibular fixation, and simultaneous access to the nose and oral cavity are needed.

  1. Primary tracheal adenocystic carcinoma and tracheal tumors during pregnancy

    Directory of Open Access Journals (Sweden)

    Cem Gundogdu

    2011-07-01

    Full Text Available Cancer complicates approximately 0.1% of all pregnancies. Primary tracheal carcinoma is one of very rarely seen tumors and the rate of its being seen makes up approximately % 0,2 of all tumors of respiratory tract. The patient, 28 years old, who has 28-weeks-pregnant, was diagnosed with primary tracheal adenocystic carcinoma. Patient was made operation as thoracotomy and tracheal tumor was removed at the 28th week of pregnancy. Patient was delivered with sectio abdominale at the 39th week of pregnancy. Primary tracheal adenocystic carcinoma is very rarely seen tumors and it is the first tracheal ACC with pregnancy case in literature to have been detected and surgically treated during pregnancy. We discussed primary tracheal adenocystic carcinoma and tracheal tumors during pregnancy with literature.

  2. Cryopreserved irradiated tracheal homograft reconstruction for subglottic-tracheal stenosis

    International Nuclear Information System (INIS)

    Somyos Kunachak; Yongyudh Vajaradul; Boonchu Kulapaditharom

    1999-01-01

    Subglottic-tracheal stenosis is a common clinical entity. Handling on severe case is often problematic. Various tracheal replacement techniques have been used with varying degree of success and dispute. In this study we worked on cryopreserved irradiated tracheal homograft, of which its use in human has not been reported. The tracheas were harvested from donor cadavers within 24 hours of death in a sterile condition. After 1-2 weeks of preservation at -70 degree C, the grafts were irradiated at 25 kGy, then stored at -70 degree C until used. Four patients, 2 males and 2 females (aged 2-40 years, mean 16 years) with severe subglottic-tracheal stenosis underwent segmental tracheal graft reconstruction using this graft. Immunosuppressant was not given in any patient. The follow up period ranged from 11-1 5 months. Three patients were successfully decapulated, 1 patient developed local infection and dislodgement of intraluminal stent with subsequent restenosis. Postoperative tracheal lumen appeared near normal with histologic evidence of normal respiratory epithelium at the grafted site. In conclusion, cryopreserved irradiated tracheal homograft is a valuable alternative for tracheal transplant or reconstruction, without the need of immunosuppression

  3. Tracheal reconstruction by re-inforced Gore-Tex in esophageal submuscular tunneling: An experimental study

    Directory of Open Access Journals (Sweden)

    Hodjati Hossein

    2011-01-01

    Full Text Available Background: Tracheal reconstructions are aimed at rearranging or replacing parts of the tracheal tissue by different techniques. Here we introduce a new technique for tracheal reconstruction. Methods: In 10 adult dogs, after intubation with an endotracheal tube, a segment of trachea including seven tracheal rings was resected circumferentially. A submuscular tunnel was induced between mucosal and muscular layers of the adjacent esophagus lying right next to the trachea. The esophageal submuscular tunnel starts and ends exactly at the level of distal and proximal ends of tracheal resection, respectively. Inforced Gore-Tex passed through the esophageal submuscular tunnel the distal segment of trachea and end-to-end anastomosis were made between distal ends of Gore-Tex and trachea, then endotracheal tube removed and the same procedure was made for proximal ends of Gore-Tex and trachea. Afterward, the proximal and distal ends of the esophageal tunnel were approximated to proximal and distal tracheal parts over the anastomosis. Results: All dogs, except one due to anesthetic problem, survived and tolerated the operation; the first two dogs experienced postoperative fever, aspiration pneumonia, and died due to tracheoesophageal fistula. All survived animals were eating and barking well. We started to scarify dogs at least 6 and 12 weeks after operation for microscopy and pathologic examination. The Gore-Texes were patent and supported externally with fibrous connective tissue in esophageal tunneling, with in growth of respiratory epithelium on inner surfaces. Conclusion: Air tightness, good re-epithelialization, and relatively no limitation of esophageal length and no risk of luminal collapse are advantages of tracheal reconstruction by submuscular esophageal tunneling. This new method is worthy of further investigation, as it is technically feasible and easy to implement.

  4. First-line tracheal resection and primary anastomosis for postintubation tracheal stenosis.

    Science.gov (United States)

    Elsayed, H; Mostafa, A M; Soliman, S; Shoukry, T; El-Nori, A A; El-Bawab, H Y

    2016-07-01

    Introduction Tracheal stenosis following intubation is the most common indication for tracheal resection and reconstruction. Endoscopic dilation is almost always associated with recurrence. This study investigated first-line surgical resection and anastomosis performed in fit patients presenting with postintubation tracheal stenosis. Methods Between February 2011 and November 2014, a prospective study was performed involving patients who underwent first-line tracheal resection and primary anastomosis after presenting with postintubation tracheal stenosis. Results A total of 30 patients (20 male) were operated on. The median age was 23.5 years (range: 13-77 years). Seventeen patients (56.7%) had had previous endoscopic tracheal dilation, four (13.3%) had had tracheal stents inserted prior to surgery and one (3.3%) had undergone previous tracheal resection. Nineteen patients (63.3%) had had a tracheostomy. Eight patients (26.7%) had had no previous tracheal interventions. The median time of intubation in those developing tracheal stenosis was 20.5 days (range: 0-45 days). The median length of hospital stay was 10.5 days (range: 7-21 days). The success rate for anastomoses was 96.7% (29/30). One patient needed a permanent tracheostomy. The in-hospital mortality rate was 3.3%: 1 patient died from a chest infection 21 days after surgery. There was no mortality or morbidity in the group undergoing first-line surgery for de novo tracheal lesions. Conclusions First-line tracheal resection with primary anastomosis is a safe option for the treatment of tracheal stenosis following intubation and obviates the need for repeated dilations. Endoscopic dilation should be reserved for those patients with significant co-morbidities or as a temporary measure in non-equipped centres.

  5. Management of benign dynamic "A-shape" tracheal stenosis: a retrospective study of 60 patients.

    Science.gov (United States)

    Plojoux, Jérôme; Laroumagne, Sophie; Vandemoortele, Thomas; Astoul, Philippe J; Thomas, Pascal A; Dutau, Hervé

    2015-02-01

    Benign tracheal stenosis complicates tracheal intubation or tracheostomy in 0.6% to 65% of cases. Surgical resection is the standard treatment. Endoscopic management is used for inoperable patients with 17% to 69% success. Dynamic "A-shape" tracheal stenosis (DATS) results in a dynamic stenosis with anterior fracture of tracheal cartilage and frequently associated posterior malacia. We report the results of our multidisciplinary management. Sixty patients with DATS were included. Management decision was made during initial bronchoscopy. When suitable, patients were referred to thoracic surgery for tracheal resection. Posterior localized tracheomalacia was treated with laser photocoagulation of the posterior tracheal wall. Tracheal stents were placed if the stenosis persisted after laser treatment. The choice of stent (straight silicone, hour-glass shaped silicone, T-tube, or fully-covered self-expandable metallic stent) was based on operator's judgment. After 12 to 18 months, stents were removed. If the stenosis persisted after stent removal, surgery was reconsidered. If surgery was not possible, a stent was replaced. In case of satisfactory result, a stent was replaced only after recurrence. Stable patients after treatment were considered as success, requirement of long-term tracheostomy or T tube as failure, and long-term stent as partial success. All patients developed DATS after tracheostomy. Thirty-three patients had posterior tracheomalacia. In 13 patients, mild stenosis required only endoscopic surveillance. Two patients were referred to thoracic surgery for tracheal resection surgery. Endoscopic management was the initial therapy in 45 patients (75%) and was considered successful in 23 patients (51%), partially successful in 10 (22%), and failed in 12 (27%). Five patients with successful outcomes required only laser therapy. Overall 70 stents were placed in 35 patients, with a migration rate of 31%. The DATS management was successful in 63%. Stent migration

  6. Management of tracheal chondrosarcoma almost completely obstructing the airway: a case report.

    Science.gov (United States)

    Andolfi, Marco; Vaccarili, Maurizio; Crisci, Roberto; Puma, Francesco

    2016-07-11

    Primary malignant tracheal tumors account for only 0.2 % of all malignancies of the respiratory tract. Tracheal chondrosarcoma is a rare condition and only 17 cases have been described in the literature from 1965 to date. Herein we report the very unusual case of a patient with a tracheal chondrosarcoma, electively treated by curative surgery despite the virtually complete obstruction of the airway. We present the case of a 79-year old Caucasian man with long-lasting wheezing misdiagnosed as asthma and affected by a tracheal chondrosarcoma almost completely obstructing the airway. Videobronchoscopy and imaging investigations revealed a well-circumscribed mass arising from the cartilaginous rings of the cervical trachea with a posterior residual respiratory space of about 1 mm. Because of the mobility and flaccidity of the uninvolved pars membranacea, the tiny respiratory space slightly expanded during inspiration and expiration allowing the patient to be treated without an essential emergency procedure. Standard tracheal intubation was impossible. Rigid bronchoscopy enabled placement of a small tracheal tube distally to the tumor. Successful cervical tracheal resection and reconstruction was then performed, achieving complete tumor excision. Histologically, the mass was characterized as a low-grade tracheal chondrosarcoma. Videobronchoscopy performed 9 months after surgery showed a wide, well healed tracheal anastomosis. Ten months after surgery, the patient is alive and disease free. Complete surgical resection is the treatment of choice for tracheal chondrosarcoma. Rigid bronchoscopy is an essential tool for diagnostic and therapeutic purposes. It allows the palliative maneuvers for obstruction relief but also, in resectable patients, the intraoperative safe and straightforward management of the obstructed airway.

  7. Time to tracheal extubation after coronary artery surgery with isoflurane, sevoflurane, or target-controlled propofol anesthesia: a prospective, randomized, controlled trial.

    Science.gov (United States)

    Parker, Francis C; Story, David A; Poustie, Stephanie; Liu, Guoming; McNicol, Larry

    2004-10-01

    To determine if anesthesia with sevoflurane or target-controlled propofol reduced the time to tracheal extubation after coronary artery bypass graft surgery compared with isoflurane anesthesia. A 3-arm (isoflurane, sevoflurane, or propofol), randomized, controlled trial with patients and intensive care staff blinded to the drug allocation. A single, tertiary referral hospital affiliated with the University of Melbourne. Three hundred sixty elective coronary artery surgery patients. Patients received either isoflurane (control group, 0.5%-2% end-tidal concentration), sevoflurane (1%-4% end-tidal concentration), or target-controlled infusion of propofol (1-8 microg/mL plasma target concentration) as part of a balanced, standardized anesthetic technique including 15 microg/kg of fentanyl. The primary outcome was time to tracheal extubation. The median time to tracheal extubation for the propofol group was 10.25 hours (interquartile range [IQR] 8.08-12.75), the sevoflurane group 9.17 hours (IQR 6.25-11.25), and the isoflurane group 7.67 hours (IQR 6.25-9.42). Intraoperatively, the propofol group required less vasopressor (p = 0.002) and more vasodilator therapy (nitroglycerin p = 0.01, nitroprusside p = 0.002). There was no difference among the groups in time to intensive care unit discharge. The median time to tracheal extubation was significantly longer for the target-controlled propofol group. A significantly greater number in this group required the use of a vasodilator to control intraoperative hypertension.

  8. [The source and factors that influence tracheal pulse oximetry signal].

    Science.gov (United States)

    Fan, Xiao-hua; Wei, Wei; Wang, Jian; Mu, Ling; Wang, Li

    2010-03-01

    To investigate the source and factors that influence tracheal pulse oximetry signal. The adult mongrel dog was intubated after anesthesia. The tracheal tube was modified by attaching a disposable pediatric pulse oximeter to the cuff. The chest of the dog was cut open and a red light from the tracheal oximeter was aligned with the deeper artery. The changes in tracheal pulse oxygen saturation (SptO2) signal were observed after the deeper artery was blocked temporarily. The photoplethysmography (PPG) and readings were recorded at different intracuff pressures. The influence of mechanical ventilation on the signal was also tested and compared with pulse oxygen saturation (SpO2). The SptO2 signal disappeared after deeper artery was blocked. The SptO2 signal changed with different intracuff pressures (P signal appeared under 20-60 cm H2O of intracuff pressure than under 0-10 cm H2O of intracuff pressure(P signal under a condition with mechanical ventilation differed from that without mechanical ventilation (P signal is primarily derived from deeper arteries around the trachea, not from the tracheal wall. Both intracuff pressures and mechanical ventilation can influence SptO2 signal. The SptO2 signal under 20-60 cm H2O of intracuff pressure is stronger than that under 0-10 em H2O of intracuff pressure. Mechanical ventilation mainly changes PPG.

  9. Tracheal resection and anastomosis after traumatic tracheal stenosis in a horse.

    Science.gov (United States)

    Barnett, Timothy P; Hawkes, Claire S; Dixon, Padraic M

    2015-02-01

    To report a resection and anastomosis technique to treat trauma-induced tracheal stenosis. Case report. A 9-year-old Warmblood gelding. Endoscopy, radiography, and ultrasonography were used to diagnose a single ring tracheal stenosis; the stenotic region was resected and adjacent tracheal rings anastomosed with an end-to-end technique. The anastomosis healed completely despite formation of a unilateral partial mucosal stenosis "web," which was subsequently removed by transendoscopic laser surgery. During tracheal anastomosis, the left recurrent laryngeal nerve was damaged, causing laryngeal hemiplegia, later treated successfully by laryngoplasty. The horse returned to its previous level of work. This tracheal resection and anastomosis technique successfully provided the horse with a large tracheal lumen, and despite major complications, allowed a return to full athletic work. © Copyright 2014 by The American College of Veterinary Surgeons.

  10. Testing Placement of Gastric Feeding Tubes in Infants.

    Science.gov (United States)

    Metheny, Norma A; Pawluszka, Ann; Lulic, Melanie; Hinyard, Leslie J; Meert, Kathleen L

    2017-11-01

    Inadvertent positioning of a nasogastric tube in the lung can cause serious complications, so identifying methods to detect improperly inserted tubes is imperative. To compare the sensitivity, specificity, and negative and positive predictive values of 4 pH cut points (< 4.0, < 4.5, < 5.0, and < 5.5) in differentiating gastric and tracheal aspirates under various treatment conditions and to explore the utility of a pepsin assay for distinguishing between gastric and tracheal aspirates. Gastric and tracheal aspirates were collected from critically ill infants undergoing mechanical ventilation who had nasogastric or orogastric feeding tubes. Aspirates were tested with colorimetric pH indicators and a rapid pepsin assay. Information about treatment conditions was obtained from medical records. Two hundred twelve gastric aspirates and 60 tracheal aspirates were collected from 212 patients. Sensitivity was highest and specificity was lowest at the gastric aspirate pH cut point of less than 5.5. Positive predictive values were 100% at all pH cut points less than 5.0. Negative predictive values were higher at the pH cut point of less than 5.0 than at cut points less than 4.5. A higher percentage of pepsin-positive readings was found in gastric aspirates (88.3%) than in tracheal aspirates (5.4%). For a desired positive predictive value of 100%, a pH cut point of less than 5.0 provides the best negative predictive values, regardless of gastric acid inhibitor administration and feeding status. The pepsin assay is promising as an additional marker to distinguish gastric from tracheal aspirates. ©2017 American Association of Critical-Care Nurses.

  11. A Prospective Observational Study of Technical Difficulty With GlideScope-Guided Tracheal Intubation in Children.

    Science.gov (United States)

    Zhang, Bin; Gurnaney, Harshad G; Stricker, Paul A; Galvez, Jorge A; Isserman, Rebecca S; Fiadjoe, John E

    2018-05-09

    The GlideScope Cobalt is one of the most commonly used videolaryngoscopes in pediatric anesthesia. Although visualization of the airway may be superior to direct laryngoscopy, users need to learn a new indirect way to insert the tracheal tube. Learning this indirect approach requires focused practice and instruction. Identifying the specific points during tube placement, during which clinicians struggle, would help with targeted education. We conducted this prospective observational study to determine the incidence and location of technical difficulties using the GlideScope, the success rates of various corrective maneuvers used, and the impact of technical difficulty on success rate. We conducted this observational study at our quaternary pediatric hospital between February 2014 and August 2014. We observed 200 GlideScope-guided intubations and documented key intubation-related outcomes. Inclusion criteria for patients were the number of advancement maneuvers required to intubate the trachea, the location where technical difficulty occurred, the types of maneuvers used to address difficulties, and the tracheal intubation success rate. We used a bias-corrected bootstrapping method with 300 replicates to determine the 95% confidence interval (CI) around the rate of difficulty with an intubation attempt. After excluding attempts by inexperienced clinicians, there were 225 attempts in 187 patients, 58% (131 of 225; bootstrap CI, 51.6%-64.6%]) of the attempts had technical difficulties. Technical difficulty was most likely to occur when inserting the tracheal tube between the plane of the arytenoid cartilages to just beyond the vocal cords: "zone 3." Clockwise rotation of the tube was the most common successful corrective maneuver in zone 3. The overall tracheal intubation success rate was 98% (CI, 95%-99%); however, the first attempt success rate was only 80% (CI, 74%-86%). Patients with technical difficulty had more attempts (median [interquartile range], 2 [1

  12. Three-finger tracheal palpation to guide endotracheal tube depth in children.

    Science.gov (United States)

    Gamble, Jonathan J; McKay, William P; Wang, Andrew F; Yip, Kinsha A; O'Brien, Jennifer M; Plewes, Christopher E

    2014-10-01

    Accurate endotracheal tube (ETT) depth is critical, especially in children. The current tools used to guide appropriate ETT depth have significant limitations. To evaluate the utility of tracheal palpation in the neck to guide appropriate ETT placement in children. A prospective observational study with a convenience sample of 50 children was conducted. During intubation, an investigator palpated the trachea with three fingertips side-by-side extending upward from the suprasternal notch. The anesthesiologist advanced the ETT slowly until palpated at the sternal notch. The investigator stated ETT palpation certainty as 'strongly felt', 'weakly felt', or 'not felt.' Final ETT position was determined by bronchoscopy and categorized as 'ETT too shallow' (tip in proximal ¼ of trachea), 'ETT too deep' (tip in distal ¼ of trachea), or 'ETT placement satisfactory' (between those extremes). Thirty boys and 20 girls undergoing dental surgery with nasal intubation were recruited (median age 4.4 years; range 2.0-10.8). The ETT (all ≥4 mm ID) was palpable at the sternal notch in all patients: 46 of 50 strongly palpable and 4 of 50 weakly palpable. The experimental methods led to satisfactory ETT placement in 49 of 50 patients, too deep in 1 of 50 patients. Compared with the Pediatrics Advanced Life Support (PALS) predictive formula, satisfactory placement would have been 41 of 50 patients (P guide ETT placement has excellent clinical performance and better guides appropriate ETT depth than the PALS formula in our study population. © 2014 John Wiley & Sons Ltd.

  13. Endoscopic Resection of Tracheal Tumor in an Elderly Woman Under Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Yi-Ying Chiang

    2011-03-01

    Full Text Available Anesthetic management of patients with difficult airway is challenging, especially in patients who present with near total occlusion of the airway. Tracheal tumors occur more frequently in elderly patients who are more prone to hypoxic injury. Reliable ventilation and oxygenation are mandatory for a safe and sound intervention. Herein, we report on a 71-year-old woman with a large tracheal tumor occluding approximately 90% of the tracheal lumen. Extracorporeal membrane oxygenation under local anesthesia was used during electrocautery resection of the tumor because of the possibility of fatal airway collapse due to the degree of occlusion and location of the tumor. After the tumor had been successfully resected by means of bronchoscopy, an endotracheal tube was inserted, and the patient was weaned from extracorporeal membrane oxygenation.

  14. Laryngeal mask airway guided tracheal intubation in a neonate with the Pierre Robin syndrome

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; Joensen, Henning; Henneberg, Steen Winther

    1995-01-01

    Endotracheal intubation in infants with the Pierre Robin syndrome may sometimes be impossible to accomplish by conventional means. To aid difficult tracheal intubation many different techniques have been described. We present a case, in which we successfully intubated a small-for-date newborn boy...... with the Pierre Robin syndrome by using a modified laryngeal mask airway (no. 1) as a guide for the endotracheal tube. The technique is easy to perform, less traumatic and less time-consuming than multiple attempts at laryngoscopy or blind tracheal intubation....

  15. Effects of successive tracheal resection and anastomosis on tracheal diameter and position of lobar bronchi in dogs.

    Science.gov (United States)

    de Mello Souza, Carlos Henrique; Reinero, Carol R

    2016-06-01

    OBJECTIVE To evaluate the effects of successive large-segment tracheal resection and anastomosis on tracheal diameter and position of lobar bronchi in dogs. ANIMALS 5 adult Beagles. PROCEDURES Right lateral radiographs were obtained for all dogs and used to measure tracheal length. Dogs were then euthanized, and successive segmental tracheal resections (intervals of 10% from 20% to 50% of the tracheal length), each of which was followed by anastomosis, were performed in each cadaver. Tracheobronchoscopy was performed before the first tracheal resection and after each of the anastomoses to evaluate tracheal diameter and changes in position of lobar bronchi. RESULTS Tracheal diameter was minimally affected by resections up to 50% of the tracheal length. Diameter of the trachea and position of bronchi were not affected by resection of 20% of the tracheal length. Changes in the position of various lobar bronchi were detected after resection of 30% of the tracheal length. CONCLUSIONS AND CLINCIAL RELEVANCE In this study, tracheal resections of 20% of the tracheal length were accommodated, possibly as a result of stretching of the annular ligament. Resections of ≥ 30% of the tracheal length altered the position of lobar bronchi. Clinical effects, if any, attributable to these changes in bronchial position remain to be elucidated.

  16. Tracheal and Crico-Tracheal Resection and Anastomosis for Malignancies Involving the Thyroid Gland and the Airway.

    Science.gov (United States)

    Piazza, Cesare; Del Bon, Francesca; Barbieri, Diego; Grazioli, Paola; Paderno, Alberto; Perotti, Pietro; Lombardi, Davide; Peretti, Giorgio; Nicolai, Piero

    2016-02-01

    To evaluate outcomes in different malignancies involving the thyroid and infiltrating the airway submitted to tracheal (TRA) or crico-tracheal resection and anastomosis (CTRA). Retrospective charts review of 27 patients affected by thyroid malignancies involving the airway treated by TRA/CTRA in a single academic institution. Kaplan-Meier curves were used to evaluate the overall (OS) and disease-specific (DSS) survivals and local (LC) and loco-regional control (LRC). Impact on survival of age, comorbidities, previous radiotherapy, types of TRA/CTRA, Shin's stage (II, III, IV), grading (well vs poorly differentiated), and length of airway resected was calculated by the log-rank test. Overall survival and DSS at 3 and 5 years were 82.3% and 71.6%, respectively. Local control and LRC in the entire group were 82.3% at 3 and 5 years. Crico-tracheal resection and anastomosis involving the cricoid arch and plate (type C) and tumor differentiation significantly affected OS and DSS (both P < .001). Type C CTRA and tumor differentiation significantly impacted on LC (P = .002 and P = .009, respectively). Grading and extension of CTRA to the cricoid plate are the most important factors for oncologic outcomes in thyroid malignancies infiltrating the airway. Except for poorly differentiated tumors, TRA/CTRA allows adequate LC even in advanced stage lesions involving the crico-tracheal junction. © The Author(s) 2015.

  17. Saccular lung cannulation in a ball python (Python regius) to treat a tracheal obstruction.

    Science.gov (United States)

    Myers, Debbie A; Wellehan, James F X; Isaza, Ramiro

    2009-03-01

    An adult male ball python (Python regius) presented in a state of severe dyspnea characterized by open-mouth breathing and vertical positioning of the head and neck. The animal had copious discharge in the tracheal lumen acting as an obstruction. A tube was placed through the body wall into the caudal saccular aspect of the lung to allow the animal to breathe while treatment was initiated. The ball python's dyspnea immediately improved. Diagnostics confirmed a bacterial respiratory infection with predominantly Providencia rettgeri. The saccular lung (air sac) tube was removed after 13 days. Pulmonary endoscopy before closure showed minimal damage with a small amount of hemorrhage in the surrounding muscle tissue. Respiratory disease is a common occurrence in captive snakes and can be associated with significant morbidity and mortality. Saccular lung cannulation is a relatively simple procedure that can alleviate tracheal narrowing or obstruction, similar to air sac cannulation in birds.

  18. CT of tracheal agenesis

    International Nuclear Information System (INIS)

    Strouse, Peter J.; Hernandez, Ramiro J.; Newman, Beverley

    2006-01-01

    Tracheal agenesis is a rare and usually lethal anomaly. In the past, opaque contrast medium was injected via the esophagus to demonstrate the anatomy. To demonstrate the utility of helical and multidetector CT in delineating the aberrant anatomy in newborns with tracheal agenesis. Four newborns with tracheal agenesis were identified from three institutions. Imaging studies and medical records were reviewed. Each child was imaged with chest radiography. One child was imaged on a single-detector helical CT scanner and the other three on multidetector scanners. Helical and multidetector CT with 2D and 3D reconstructions clearly delineated the aberrant tracheobronchial and esophageal anatomy in each infant. Minimum intensity projection reformatted CT images were particularly helpful. One infant each had type I and type II tracheal agenesis. Two infants had type III tracheal agenesis. All four infants died. CT is a useful tool for delineating the aberrant anatomy of newborns with tracheal agenesis and thus helps in making rational clinical decisions. (orig.)

  19. Validation study of two-microphone acoustic reflectometry for determination of breathing tube placement in 200 adult patients.

    Science.gov (United States)

    Raphael, David T; Benbassat, Maxim; Arnaudov, Dimiter; Bohorquez, Alex; Nasseri, Bita

    2002-12-01

    Acoustic reflectometry allows the construction of a one-dimensional image of a cavity, such as the airway or the esophagus. The reflectometric area-distance profile consists of a constant cross-sectional area segment (length of endotracheal tube), followed either by a rapid increase in the area beyond the carina (tracheal intubation) or by an immediate decrease in the area (esophageal intubation). Two hundred adult patients were induced and intubated, without restrictions on anesthetic agents or airway adjunct devices. A two-microphone acoustic reflectometer was used to determine whether the breathing tube was placed in the trachea or esophagus. A blinded reflectometer operator, seated a distance away from the patient, interpreted the acoustic area-distance profile alone to decide where the tube was placed. Capnography was used as the gold standard. Of 200 tracheal intubations confirmed by capnography, the reflectometer operator correctly identified 198 (99% correct tracheal intubation identification rate). In two patients there were false-negative results, patients with a tracheal intubation were interpreted as having an esophageal intubation. A total of 14 esophageal intubations resulted, all correctly identified by reflectometry, for a 100% esophageal intubation identification rate. Acoustic reflectometry is a rapid, noninvasive method by which to determine whether breathing tube placement is correct (tracheal) or incorrect (esophageal). Reflectometry determination of tube placement may be useful in airway emergencies, particularly in cases where visualization of the glottic area is not possible and capnography may fail, as in patients with cardiac arrest.

  20. Tracheal growth after resection and anastomosis in puppies.

    Science.gov (United States)

    Blanchard, H; Brochu, P; Bensoussan, A L; Lagacé, G; Khan, A H

    1986-09-01

    Tracheal morphology, morphometric changes, and growth and histologic changes were studied in puppies submitted to tracheal resection and anastomosis. Fifteen mongrel puppies about 12 weeks old and weighing on an average 5.5 kg were operated under general anesthesia using fluothane. A median cervicotomy incision was made in ten puppies (experimental group, EG) and the proximal 14 tracheal rings were resected (average length 5.08 cm or about 35% to 38% of total tracheal length). One layer anastomosis was done using vicryl 4.0 maintaining the average tension of 1,450 g. Five puppies (control group, CG) were submitted to tracheal transection and anastomosis and the following parameters were studied. Tracheal morphology the trachea of the EG was a rounded triangle whereas in the CG it was oval in shape, there was increase in the intercartilageneous spaces in the EG, no granulation tissue was present, two mucous webs were seen in the EG and one in the CG. Morphometric changes average tracheal length EG 13 cm, CG 17.7 cm, intercartilagenous space EG 3.08 mm, CG 1.3 mm, intercricothyroid space EG 1.2 cm, CG 0.53 cm, sagittal and transverse tracheal thickness at the anastomosis EG 2.6 and 3.3 mm, CG 2 and 1.5 mm, sagittal and transverse diameter reduced on an average 2 mm in EG. Histology Moderate fibrosis was found at the level of anastomosis with no modification of chondrocytes at the cartilagenous rings in the EG. Even with high anastomotic tension, the dogs had normal tracheal growth without stenosis; the sagittal and transverse growth at the anastomosis in the EG was 90% and 85%, respectively, when compared with the CG.

  1. [Cervical tracheal resection with primary anastomosis for benign tracheal stricture in adult].

    Science.gov (United States)

    Ye, Jin; Hu, Yan-Ming; Liu, Hui; Li, Jing-Jia; Wang, Zhi-Yuan; Li, Yuan

    2013-07-01

    To introduce the outcomes of tracheal resection with primary end to end anastomosis for benign cervical tracheal stenosis, and to discuss the strategy for prevention of surgical complications. A retrospective analysis was performed in 12 patients diagnosed as benign cervical tracheal stenosis from October 2009 to June 2012. Laryngo-tracheal endoscopic examination and computed tomography (CT) were used to assess the degree of stenosis, the grade of inflammation and edema of the subglottis and trachea, and the extent of stenosis and the remaining linear amount of normal airway. The Meyer and Cotton grading system was used to categorise the clinical severity of the stenoses. All patients underwent tracheal resection with primary end to end anastomosis. The length of cervical tracheal stenosis ranged from 2.3 to 4.1 cm. Grade II stenosis was present in three patients, Grade III stenosis was present in seven patients and grade IV stenosis in two patients. Successful extubation was achieved in all 12 cases. After surgery, temporary hoarseness occurred in 1 patient (8.3%); unilateral pulmonary atelectasis with pleural effusion occurred in 1 patient (8.3%); subcutaneous emphysema with infection occurred in 1 patient (8.3%); mild dysphagia occurred in 3 patients (25.0%); a slight deepening of the tone of voice occurred in 5 patients (41.7%), granulation tissue growth near the suture occurred in 3 patients (25.0%), and suture dehiscence did not occur in any patient. The follow-up period ranged from 6 months to 38 months, no patient developed restenosis. It presents a high success rate and good functional result of tracheal resection with primary end-to-end anastomosis. Therefore, it is an effective and reliable approach for the management of benign cervical tracheal stenosis. To avoid complications, the preoperative assessment, patients selection and postoperative management should be emphasized.

  2. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants—the impact of ventilator settings on tracheal pressure swings

    International Nuclear Information System (INIS)

    Hentschel, Roland; Buntzel, Julia; Guttmann, Josef; Schumann, Stefan

    2011-01-01

    Resistive properties of endotracheal tubes (ETTs) are particularly relevant in newborns and small infants who are generally ventilated through ETTs with a small inner diameter. The ventilation rate is also high and the inspiratory time (ti) is short. These conditions effectuate high airway flows with excessive flow acceleration, so airway resistance and inertance play an important role. We carried out a model study to investigate the impact of varying ETT size, lung compliance and ventilator settings, such as peak inspiratory pressure (PIP), positive end expiratory pressure (PEEP) and inspiratory time (ti) on the pressure–flow characteristics with respect to the resistive and inertive properties of the ETT. Pressure at the Y piece was compared to direct measurement of intratracheal pressure (P trach ) at the tip of the ETT, and pressure drop (ΔP ETT ) was calculated. Applying published tube coefficients (Rohrer's constants and inertance), P trach was calculated from ventilator readings and compared to measured P trach using the root-mean-square error. The most relevant for ΔP ETT was the ETT size, followed by (in descending order) PIP, compliance, ti and PEEP, with gas flow velocity being the principle in common for all these parameters. Depending on the ventilator settings ΔP ETT exceeded 8 mbar in the smallest 2.0 mm ETT. Consideration of inertance as an additional effect in this setting yielded a better agreement of calculated versus measured P trach than Rohrer's constants alone. We speculate that exact tracheal pressure tracings calculated from ventilator readings by applying Rohrer's equation and the inertance determination to small size ETTs would be helpful. As an integral part of ventilator software this would (1) allow an estimate of work of breathing and implementation of an automatic tube compensation, and (2) be important for gentle ventilation in respiratory care, especially of small infants, since it enables the physician to

  3. The therapeutic effects and experience of tracheal stent implantation in managing severe tracheal stenosis

    International Nuclear Information System (INIS)

    Lv Weifu; Zhang Xingming; Zhang Xuebing; Wang Weiyu; Hou Changlong

    2006-01-01

    Objective: To evaluate the therapeutic effects and experience of the tracheal stent implantation for the management of severe tracheal stenosis. Materials: Thirteen patients with severe tracheal stenosis of various causes underwent high kilovoltage radiography and computed tomography for evaluating the site, form and extent of the stenosis including 10 at the trachea, 1 at the right main bronchus and 2 at left main bronchus. The C2 catheter assisted with ultra-slipping guide wire was inserted into the trachea under fluoroscopy and then a replaced high shoring guide wire was pushed through the stenotic segment and retained the stent. Results: All stents were implanted successfully with successful rate 100% together with dyspnoeic improvements. The mean survival time was 6.2 months for patients with malignant neoplasm. One patient with benign tracheal stenosis has been followed-up for 5 years without restenosis. Conclusions: The tracheal stent implantation is an effective means for severe tracheal stenosis. (authors)

  4. Successful conservative management of a rare complication of tracheostomy; extensive posterior tracheal false pouch.

    Science.gov (United States)

    Ha, Jennifer F; Ostwani, Waseem; Green, Glenn

    2016-11-01

    With the advent of improved neonatal and pediatric intensive care management, tracheostomy is increasingly performed in children requiring prolonged ventilation. Even though tracheostomy is generally a safe procedure, there remains mortality and morbidity associated with it. We report a rare complication of a tracheostomy tube resulting in extensive erosion and posterior tracheal false pouch secondary to a large tracheostomy tube and high positive end expiratory pressure in a 12-month-old infant. This was managed successfully with conservative treatment. A former 34-week premature infant was transferred to our pediatrics intensive care unit (PICU) with recurrent episodes of cardiopulmonary arrests due to suspected severe tracheobronchomalacia. The patient has bronchopulomonary dysplasia, severe restrictive lung disease and thoracic insufficiency from skeletal dysplasia requiring tracheostomy tube (TT) at two-month-old and mechanical ventilation. The 3.5 NEO TT was gradually upsized to a 5. The PEEP setting at transfer was 18cmH2O. The direct laryngoscopy and bronchoscopy showed moderate tracheomalacia at the innominate artery with a false pouch in the posterior tracheal wall that was 1.1cm below the tracheostomy stoma. A multi-disciplinary discussion including otolaryngology, PICU, Pulmonary Medicine, and Pediatric Surgery decided on conservative management. The false pouch healed and she was transferred back to referring PICU after a 46-day. Tracheal wall erosion resulting in a pouch formation is a rare complication, but it should be considered in patients with long term tracheostomy with difficulty ventilation and oxygenation with positional change. DLB is a useful tool in its diagnosis and conservative management can be successful. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. [Segmental tracheal resection and anastomosis for the treatment of cicatricial stenosis in cervical tracheal].

    Science.gov (United States)

    Cui, P C; Luo, J S; Liu, Z; Bian, K; Guo, Z H; Ma, R N

    2016-02-01

    To evaluate the efficacy of segmental tracheal resection with end-to-end anastomosis for cicatricial cervical tracheal stenosis. The clinical outcomes of 40 patients treated with tracheal resection were retrospectively reviewed. There were 28 male patients and 12 female patients with the age ranged from 6 to 64 years (mean 33.7 years). The degree of stenosis was classified according to Myer-Cotton classification as follows: grade Ⅱ (n=7), grade Ⅲ (n=22) and grade Ⅳ (n=11). The stenosis extension ranged from 1.0 to 4.3 cm (mean 2.5 cm). The causes of the stenosis were postintubation (n=33), cervical trauma (n=6) and resection of tracheal neoplasm (n=1). Thirty-four(85.0%) patients were decannulated and 6 failed. Of the 6 patients failed, 4 were decannulated after reoperation with the sternohyoid myocutaneous flap or thyroid alar cartilage graft. Complications occurred in 10 patients. In 8 patients granulation tissues formed at the site of the tracheal anastomosis, which needed endoscopic resction, and in 2 patients anastomosic dehiscence occurred. No injury to recurrent laryngeal nerve or trachoesophageal fistula occurred. Segmental tracheal resection with end-to-end anastomosis is an effective surgical method for tracheal stenosis, which has a higher successful rate for primary operation and shorter therapeutic period.

  6. Iatrogenic tracheal tear.

    LENUS (Irish Health Repository)

    Dias, A

    2010-10-01

    Large post intubation tracheal tears are usually detected intra-operatively due to unstable signs namely impaired ventilation and mediastinal emphysema and often require surgical management. Smaller tracheal tears are often missed during anaesthesia and recognized during the postoperative period. Conservative management should be considered in these latter cases.

  7. [Self-expanding nitinol stents in proximal tracheal stenosis].

    Science.gov (United States)

    Hafner, B; Mann, W; Heussel, C P; Scherhag, A; Schlegel, J; Kauczor, H U

    2000-03-01

    The use of silicone- or metal stents in stenosis of the distal trachea and the bronchial system is a customary procedure [1-4], for example after tumor invasion or cicatricial stenosis after transplantation. In the proximal part of the trachea, on smaller, short and soft strictures we try to stabilise the trachea by the implantation of rings. Other methods are tracheal plasty or transverse tracheal resectomy [5-7]. In the case of longer or nearer subglottal stenoses the positioning of self-expanding nitinol stents has proven a simple, gentle and well-tolerated alternative procedure even in very serious disorders [1, 8, 9]. These stents can be placed in short narcosis under endoscopic control without great strain on the patient. We placed nitinol-stents in the proximal part of the trachea in eleven cases. In five cases dyspnoea caused by a tracheal collapse improved. In two further cases a tracheal stenosis with massive granulation tissue and cicatricial pull under an inlaid tracheal cannula was removed and the tracheostoma was closed. In four cases a solid, scarred and cartilaginous stenosis in the area of the cricoid and the upper tracheal rings was widened with laser and later on stented. Over an observation time of two years no complications showed safe one case in which a directly postoperative dislocation was repositioned quickly. The patients live without restrictions through the tracheal stenosis or a tracheostoma. In the best possible case epithelialization over the metal meshes develops so that a nearly normal mucus transportation is possible [1, 10-12].

  8. Ex vivo tracheomalacia model with 3D-printed external tracheal splint.

    Science.gov (United States)

    Kaye, Rachel; Goldstein, Todd; Aronowitz, Danielle; Grande, Daniel A; Zeltsman, David; Smith, Lee P

    2017-04-01

    To design and evaluate an ex vivo model of tracheomalacia with and without a three-dimensional (3D)-printed external tracheal splint. Prospective, ex vivo animal trial. Three groups of ex vivo porcine tracheas were used: 1) control (unmanipulated trachea), 2) tracheomalacia (tracheal rings partially incised and crushed), and 3) splinted tracheomalacia (external custom tracheal splint fitted onto group 2 trachea). Each end of an ex vivo trachea was sealed with a custom-designed and 3D-printed cap; a transducer was placed through one end to measure the pressure inside the trachea. Although the negative pressure was applied to the tracheal lumen, the tracheal wall collapse was measured externally and internally using a bronchoscope. Each group had at least three recorded trials. Tracheal diameter was evaluated using ImageJ software (National Institutes of Health, Bethesda, MD) and was averaged between two raters. Average tracheal occlusion percentage was compared using Student t test. The average occlusion was 31% for group 1, 87.4% for group 2, and 20% for group 3. Significant differences were found between the control and tracheomalacia groups (P tracheomalacia and splinted tracheomalacia groups (P tracheomalacia groups (P = 0.13). Applied pressure was plotted against occlusion and regression line slope differed between the tracheomalacia (0.91) and control (0.12) or splinted tracheomalacia (0.39) groups. We demonstrate the potential for an ex vivo tracheomalacia model to reproduce airway collapse and show that this collapse can be treated successfully with a 3D-printed external splint. These results are promising and justify further studies. N/A. Laryngoscope, 127:950-955, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Efeitos da pressão limite (25 cmH2O e mínima de “selo” do balonete de tubos traqueais sobre a mucosa traqueal do cão Efectos de la presión limite (25 cmH2O y mínima de “sello” del balón de tubos traquéales sobre la mucosa traqueal del can Effects of tracheal tube cuff limit pressure (25 cmH2O and “seal” pressure on tracheal mucosa of dogs

    Directory of Open Access Journals (Sweden)

    Emanuel Celice Castilho

    2003-12-01

    ón del tubo traqueal insuflado con volumen de aire suficiente para obtener presión de “sello” o con la presión limite de 25 cmH2O, abajo de la presión crítica de 30 cm de agua para producción de lesión de la mucosa traqueal. MÉTODO: Diez y seis canes fueron sometidos a anestesia venosa y ventilación artificial. Los canes fueron distribuidos aleatoriamente en dos grupos de acuerdo con la presión en el balón del tubo traqueal (Portex Blue-Line, Inglaterra: Gsello (n = 8 balón con presión mínima de “sello” para impedir vaciamiento de aire durante la respiración artificial; G25 (n = 8 balón insuflado hasta la obtención de la presión de 25 cmH2O. La medida de la presión del balón fue realizada por medio de manómetro digital en el inicio (control y después de 60, 120 y 180 minutos. Después del sacrificio de los canes, fueron hechas biopsias en las áreas de la mucosa traqueal adyacentes al balón y al tubo traqueal para análisis de microscopio electrónico de barredura (MEV. RESULTADOS: La presión media del balón en G25 se mantuvo entre 24,8 y 25 cmH2O y en Gsello entre 11,9 y 12,5 cmH2O durante el experimento. Las alteraciones a la MEV fueron pequeñas y no significantemente diferentes en los grupos (p > 0,30, pero ocurrieron lesiones más intensas en las áreas de contacto de la mucosa traqueal con el balón del tubo traqueal, en los dos grupos, en relación a las áreas de la mucosa adyacentes o no al tubo traqueal (p BACKGROUND AND OBJECTIVES: Injuries of tracheal mucosa in contact with tracheal tube cuff is a function of cuff pressure and exposure time. This study aimed at analyzing injuries of tracheal mucosa in contact with tracheal tube cuff inflated to reach “seal” pressure or limit 25 cmH2O pressure, below critical 30 cmH2O, to prevent tracheal damage. METHODS: This study involved 16 dogs submitted to intravenous anesthesia and artificial ventilation. Dogs were randomly distributed into two experimental groups according to

  10. Tracheal collapse in two cats

    International Nuclear Information System (INIS)

    Hendricks, J.C.; O'Brien, J.A.

    1985-01-01

    Two cats examined bronchoscopically to discover the cause of tracheal collapse were found to have tracheal obstruction cranial to the collapse. Cats with this unusual sign should be examined bronchoscopically to ascertain whether there is an obstruction, as the cause in these 2 cats was distinct from the diffuse airway abnormality that causes tracheal collapse in dogs

  11. Intubação traqueal Tracheal intubation

    Directory of Open Access Journals (Sweden)

    Toshio Matsumoto

    2007-05-01

    keywords intubation, tracheal intubation, child, rapid sequence intubation and pediatric airway. SUMMARY OF THE FINDINGS: Airway management in children is related to their physiology and anatomy, in addition to specific factors (inherent pathological conditions, such as malformations or acquired conditions which have a decisive influence on success. Principal indications are in order to maintain the airway patent and to control ventilation. Laryngoscopy and tracheal intubation cause cardiovascular alterations and affect airway reactivity. The use of tubes with cuffs is not prohibited, as long as the correct size for the child is chosen. A difficult airway can be identified against the Mallampati scale and by direct laryngoscopy. Rapid sequence intubation is being recommended more and more often in pediatrics, since it facilitates the procedure and presents fewer complications. Tracheal intubation should be carried out in an adequate manner in special circumstances (eaten recently, neurological dysfunction, unstable spinal column, upper airway obstruction, laryngotracheal injuries, injuries to the eyeball. Extubation should be meticulously planned, since there is chance of failure and a need for reintubation. CONCLUSIONS: Tracheal intubation of children requires knowledge, skill and experience, since, if the procedure is carried out by inexperienced pediatricians, it can result in life-threatening complications.

  12. An ovine tracheal explant culture model for allergic airway inflammation

    Directory of Open Access Journals (Sweden)

    Abeynaike Latasha

    2010-08-01

    Full Text Available Abstract Background The airway epithelium is thought to play an important role in the pathogenesis of asthmatic disease. However, much of our understanding of airway epithelial cell function in asthma has been derived from in vitro studies that may not accurately reflect the interactive cellular and molecular pathways active between different tissue constituents in vivo. Methods Using a sheep model of allergic asthma, tracheal explants from normal sheep and allergic sheep exposed to house dust mite (HDM allergen were established to investigate airway mucosal responses ex vivo. Explants were cultured for up to 48 h and tissues were stained to identify apoptotic cells, goblet cells, mast cells and eosinophils. The release of cytokines (IL-1α, IL-6 and TNF-α by cultured tracheal explants, was assessed by ELISA. Results The general morphology and epithelial structure of the tracheal explants was well maintained in culture although evidence of advanced apoptosis within the mucosal layer was noted after culture for 48 h. The number of alcian blue/PAS positive mucus-secreting cells within the epithelial layer was reduced in all cultured explants compared with pre-cultured (0 h explants, but the loss of staining was most evident in allergic tissues. Mast cell and eosinophil numbers were elevated in the allergic tracheal tissues compared to naïve controls, and in the allergic tissues there was a significant decline in mast cells after 24 h culture in the presence or absence of HDM allergen. IL-6 was released by allergic tracheal explants in culture but was undetected in cultured control explants. Conclusions Sheep tracheal explants maintain characteristics of the airway mucosa that may not be replicated when studying isolated cell populations in vitro. There were key differences identified in explants from allergic compared to control airways and in their responses in culture for 24 h. Importantly, this study establishes the potential for the

  13. Intermittent subglottic secretion drainage may cause tracheal damage in patients with few oropharyngeal secretions.

    Science.gov (United States)

    Suys, E; Nieboer, K; Stiers, W; De Regt, J; Huyghens, L; Spapen, H

    2013-12-01

    Injurious prolapse of tracheal mucosa into the suction port has been reported in up to 50% of intubated patients receiving continuous aspiration of subglottic secretions. We investigated whether similar injury could be inflicted by automated intermittent aspiration. Six consecutive patients, intubated with the Mallinckrodt TaperGuard Evac™ endotracheal tube, were studied. A flow sensor was placed between the vacuum regulating system and the mucus collector. Intermittent suctioning was performed at a pressure of -125 mmHg with a 25s interval and duration of 15s. After 24h, a CT scan of the tracheal region was performed. Excessive negative suction pressure, a fast drop in aspiration flow to zero, and important "swinging" movements of secretions in the evacuation line were observed in all patients. Oral instillation of antiseptic mouthwash restored normal aspiration flow and secretion mobility. CT imaging showed marked entrapment of tracheal mucosa into the suction port in all patients. In patients with few oropharyngeal secretions, automated intermittent subglottic aspiration may result in significant and potential harmful invagination of tracheal mucosa into the suction lumen. A critical amount of fluid must be present in the oropharynx to assure adequate and safe aspiration. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. X-ray tube current control

    International Nuclear Information System (INIS)

    Dupuis, W.A.; Resnick, T.A.

    1982-01-01

    A closed loop feedback system for controlling the current output of an x-ray tube. The system has circuitry for improving the transient response and stability of the x-ray tube current over a substantial nonlinear portion of the tube current production characteristic. The system includes a reference generator for applying adjustable step function reference signals representing desired tube currents. The system also includes means for instantaneous sensing of actual tube current. An error detector compares the value of actual and reference tube current and produces an error signal as a function of their difference. The system feedback loop includes amplification circuitry for controlling x-ray tube filament dc voltage to regulate tube current as a function of the error signal value. The system also includes compensation circuitry, between the reference generator and the amplification circuitry, to vary the loop gain of the feedback control system as a function of the reference magnitude

  15. A comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: A randomised, controlled clinical trial.

    LENUS (Irish Health Repository)

    Maharaj, C H

    2006-11-01

    The Airtraq laryngoscope is a novel single use tracheal intubation device. We compared the Airtraq with the Macintosh laryngoscope in patients deemed at low risk for difficult intubation in a randomised, controlled clinical trial. Sixty consenting patients presenting for surgery requiring tracheal intubation were randomly allocated to undergo intubation using a Macintosh (n = 30) or Airtraq (n = 30) laryngoscope. All patients were intubated by one of four anaesthetists experienced in the use of both laryngoscopes. No significant differences in demographic or airway variables were observed between the groups. All but one patient, in the Macintosh group, was successfully intubated on the first attempt. There was no difference between groups in the duration of intubation attempts. In comparison to the Macintosh laryngoscope, the Airtraq resulted in modest improvements in the intubation difficulty score, and in ease of use. Tracheal intubation with the Airtraq resulted in less alterations in heart rate. These findings demonstrate the utility of the Airtraq laryngoscope for tracheal intubation in low risk patients.

  16. Tracheal quadrifurcation associated with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, Venkatraman; Gadabanahalli, Karthik; Ahmad, Ozaire [Narayana Multispeciality Hospital and Mazumdar Shaw Cancer Center, Department of Radiology, Bangalore (India)

    2015-08-15

    Tracheal anomalies are known in association with congenital cardiac defects. Some of the well-described anomalies include accessory (displaced) tracheal bronchus with variants, tracheal trifurcation and accessory cardiac bronchus. Here we describe a case of tracheal quadrifurcation associated with complex congenital heart disease. Illustration of complex airway anatomy was simplified by the use of multidetector CT using a variety of image display options. Awareness of this complex anomaly will expand our knowledge of tracheal anomalies and equip the anesthesia and surgical team for better airway management. (orig.)

  17. Management of complex benign post-tracheostomy tracheal stenosis with bronchoscopic insertion of silicon tracheal stents, in patients with failed or contraindicated surgical reconstruction of trachea.

    Science.gov (United States)

    Tsakiridis, Kosmas; Darwiche, Kaid; Visouli, Aikaterini N; Zarogoulidis, Paul; Machairiotis, Nikolaos; Christofis, Christos; Stylianaki, Aikaterini; Katsikogiannis, Nikolaos; Mpakas, Andreas; Courcoutsakis, Nicolaos; Zarogoulidis, Konstantinos

    2012-11-01

    Tracheal stenosis is a potentially life-threatening condition. Tracheostomy and endotracheal intubation remain the commonest causes of benign stenosis, despite improvements in design and management of tubes. Post-tracheostomy stenosis is more frequently encountered due to earlier performance of tracheostomy in the intensive care units, while the incidence of post-intubation stenosis has decreased with application of high-volume, low-pressure cuffs. In symptomatic benign tracheal stenosis the gold standard is surgical reconstruction (often after interventional bronchoscopy). Stenting is reserved for symptomatic tracheal narrowing deemed inoperable, due to local or general reasons: long strictures, inflammation, poor respiratory, cardiac or neurological status. When stenting is decided, silicone stent insertion is considered the treatment of choice in the presence of inflammation and/or when removal is desirable. We inserted tracheal silicone stents (Dumon) under general anaesthesia through rigid bronchoscopy in two patients with benign post-tracheostomy stenosis: a 39-year old woman with failed initial operation, and continuous relapses with proliferation after multiple bronchscopic interventions, and a 20-year old man in a poor neurological status, with a long tracheal stricture involving the subglottic larynx (lower posterior part), and inflamed tracheostomy site tissues (positive for methicillin resistant staphylococcus aureus). The airway was immediately re-establish, without complications. At 15- and 10-month follow-up (respectively) there was no stent migration, luminal patency was maintained without: adjacent structure erosion, secretion adherence inside the stents, granulation at the ends. Tracheostomy tissue inflammation was resolved (2(nd) patient), new infection was not noted. The patients maintain good respiratory function and will be evaluated for scheduled stent removal. Silicone stents are removable, resistant to microbial colonization and are

  18. [Tracheal Intubation by Paramedics in a Local Community: Current Situation and Future Challenges].

    Science.gov (United States)

    Takinami, Yoshikazu

    2016-03-01

    As of April 2013, 164 paramedics are certified to perform tracheal intubation in Fukui Prefecture. This study investigated the current situation surrounding tracheal intubation performed by paramedics in prehospital care. Subjects were 58 paramedics who completed practical training at our hospital. Post-training duration, number of tracheal intubation cases, number of attempts before successful tracheal intubation, disease involved, rate of return of spontaneous circulation, and prognosis were examined. Tracheal intubation was successful on the first attempt in 92% of cases. Rate of return of spontaneous circulation was high in paramedics whose post-training duration was short. No return of spontaneous circulation occurred after a second attempt. Four patients survived asphyxia or aspiration. It is important to perform successful tracheal intubation on the first attempt, to recognize the probability of successful resuscitation in patients with exogenous disease, and to strengthen the medical control system.

  19. An in vitro comparison of tracheostomy tube cuffs

    Directory of Open Access Journals (Sweden)

    Maguire S

    2015-04-01

    Full Text Available Seamus Maguire,1 Frances Haury,2 Korinne Jew2 1Research and Development, Covidien Respiratory and Monitoring Solutions, Athlone, Ireland; 2Medical Affairs, Covidien Respiratory and Monitoring Solutions, Boulder, CO, USA Introduction: The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT] with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force.Methods: Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O, instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site.Results: The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05. The taper

  20. [The cause and efficacy of benign tracheal stenosis].

    Science.gov (United States)

    Su, Zhu-quan; Wei, Xiao-qun; Zhong, Chang-hao; Chen, Xiao-bo; Luo, Wei-zhan; Guo, Wen-liang; Wang, Ying-zhi; Li, Shi-yue

    2013-09-01

    To analysis the causes of benign tracheal stenosis and evaluate the curative effect of intraluminal bronchoscopic treatment. 158 patients with benign tracheal stenosis in our hospital from September 2005 to September 2012 were collected to retrospectively analysis the causes and clinic features of tracheal stenosis. Interventional treatments through bronchoscopy were used to treat the benign tracheal stenosis and the curative effects were evaluated. 158 cases of benign tracheal stenosis were recruited to our study, 69.6% of them were young and middle-aged. The main causes of benign tracheal stenosis were as follows: secondary to postintubation or tracheotomy in 61.4% (97/158), tuberculosis in 16% (26/158), benign tumor in 5.1% (8/158) and other 27 cases. 94.3% patients improved in symptoms with alleviation immediately after bronchoscopic treatment, the average tracheal diameter increased form (4.22 ± 2.06) mm to (10.16 ± 2.99) mm (t = 21.48, P benign tracheal stenosis were increasing year by year. The most common cause of benign tracheal stenosis was postintubation and tracheotomy. Interventional treatments through bronchoscopy is effective in treating benign tracheal stenosis, but repeated interventional procedures may be required to maintain the favorable long-term effects.

  1. Nitinol memmo-alloy stents for benign and malignant tracheal stensis

    International Nuclear Information System (INIS)

    Wang Zhongmin; Wu Chaoxian; Gong Ju; Zheng Yunfeng; Gu Xuezhang

    2005-01-01

    Objective: To observe the therapeutic and side effects of tracheal stents in tracheal stenosis caused by tracheal malacia and malignant tumours. Methods: Twenty-five patients treated with tracheal stents were retrospectively analyzed. Results: Tracheal stents have been implanted successfully in twenty-five patients through fiberbronchoscope or tracheal intubation, and dyspnoea improved greatly after the procedure. Conclusions: Tracheal stents can relieve symptoms and improve the life quality in patients with tracheal stenosis caused by malignant tumors or tracheal malacia. (authors)

  2. Laryngeal Preservation in Managing Advanced Tracheal Adenoid Cystic Carcinoma

    Directory of Open Access Journals (Sweden)

    Thavakumar Subramaniam

    2015-01-01

    Full Text Available A 37-year-old male athlete was diagnosed with primary tracheal adenoid cystic carcinoma following investigation for dyspnea, wheeze, and eventual stridor. Preoperative bronchoscopy revealed a highly vascular tumor 4 cm distal to the cricoid with no gross disease extending to the carina. Imaging revealed circumferential tracheal irregularity immediately inferior to the cricoid, with no definite cricoid invasion. Locoregional extension of disease was noted invading the thyroid and abutment of the carotid approximately 180°. Intraoperative findings identified tracheal mucosal disease extending distal to the carina and proximally at the cricothyroid joints where bilateral functional recurrent nerves were preserved. A decision made to preserve the larynx given the inability to fully resect distal tracheal disease. A 5 cm sleeve resection of the trachea was made with a cricotracheal anastomosis following suprahyoidal muscle release and laryngeal drop-down. The patient was treated with adjuvant radiotherapy including platinum based chemotherapy in an effort to maximise local control. PET scanning three months after therapy revealed no FDG uptake locally or distally.

  3. Patients with cardiac arrest are ventilated two times faster than guidelines recommend : An observational prehospital study using tracheal pressure measurement

    NARCIS (Netherlands)

    Maertens, Vicky L.; De Smedt, Lieven E. G.; Lemoyne, Sabine; Huybrechts, Sofie A. M.; Wouters, Kristien; Kalmar, Alain F.; Monsieurs, Koenraad G.

    Aim: To measure ventilation rate using tracheal airway pressures in prehospitally intubated patients with and without cardiac arrest. Methods: Prospective observational study. In 98 patients (57 with and 41 without cardiac arrest) an air-filled catheter was inserted into the endotracheal tube and

  4. I-gel Laryngeal Mask Airway Combined with Tracheal Intubation Attenuate Systemic Stress Response in Patients Undergoing Posterior Fossa Surgery

    Directory of Open Access Journals (Sweden)

    Chaoliang Tang

    2015-01-01

    patients. In this study, we proposed that I-gel combined with tracheal intubation could reduce the stress response of posterior fossa surgery patients. Methods. Sixty-six posterior fossa surgery patients were randomly allocated to receive either tracheal tube intubation (Group TT or I-gel facilitated endotracheal tube intubation (Group TI. Hemodynamic and respiratory variables, stress and inflammatory response, oxidative stress, anesthesia recovery parameters, and adverse events during emergence were compared. Results. Mean arterial pressure and heart rate were lower in Group TI during intubation and extubation (P<0.05 versus Group TT. Respiratory variables including peak airway pressure and end-tidal carbon dioxide tension were similar intraoperative, while plasma β-endorphin, cortisol, interleukin-6, tumor necrosis factor-alpha, malondialdehyde concentrations, and blood glucose were significantly lower in Group TI during emergence relative to Group TT. Postoperative bucking and serious hypertensions were seen in Group TT but not in Group TI. Conclusion. Utilization of I-gel combined with endotracheal tube in posterior fossa surgery patients is safe which can yield more stable hemodynamic profile during intubation and emergence and lower inflammatory and oxidative response, leading to uneventful recovery.

  5. Tracheal tube airleak in clinical practice and impact on tidal volume measurement in ventilated neonates.

    Science.gov (United States)

    Mahmoud, Ramadan A; Proquitté, Hans; Fawzy, Naglaa; Bührer, Christoph; Schmalisch, Gerd

    2011-03-01

    To determine the prevalence, size, and factors affecting tracheal tube (TT) leak in clinical practice and their influence on the displayed tidal volume (Vt) in ventilated newborn infants using uncuffed TTs. Monitoring of Vt is important for implementation of lung-protective ventilation strategies but becomes meaningless in the presence of large TT airleaks. Retrospective clinical study. Neonatal intensive care unit. Patient records of 163 neonates ventilated with Babylog 8000 for ≥ 5 hrs with a median (range) gestation age of 31.1 wks (23.3-41.9 wks) and a median birth weight of 1470 g (410-4475 g) were evaluated. : Ventilatory settings, TT leak, and Vt were recorded every 3 hrs. The lowest, median, and highest TT leaks were noted on the day the first TT leak (>5%) occurred, the day on which TT leak peaked, and the day of extubation. A TT leak of >5% was seen in 122 (75%) infants. Neonates with TT leak, compared with those without TT leak, had a longer duration of mechanical ventilation (p 40% commonly seen on the third day of mechanical ventilation. Regression analysis showed that a TT leak of 40% indicated that the displayed Vt was underestimated by 1.2 mL/kg (about 24% of target Vt). TT leak is highly variable, and TT leak of >40% with clinically relevant Vt errors occurred in nearly half of all ventilated neonates. Preterm infants of low birth weight and with small-diameter TTs ventilated for a long period were at greater risk of TT leak.

  6. Evaluation of tracheal bronchus in Chinese children using multidetector CT

    International Nuclear Information System (INIS)

    Ming, Zhu; Lin, Zhang

    2007-01-01

    Tracheal bronchus is a congenital bronchial anomaly. The diagnosis should be considered early in intubated patients. Multidetector computed tomography (MDCT) is the newest modality for evaluating tracheal bronchus. To evaluate the utility of 16-slice MDCT in children with tracheal bronchus and to characterize the frequency of tracheal bronchus in children with congenital heart disease. From June 2005 to May 2007, 3,187 consecutive children (1,124 with congenital heart disease and 2,063 without congenital heart disease) underwent MDCT examination. Minimum-intensity projection reconstruction was performed to show the tracheobronchial tree in every case. Tracheal bronchus was found in 42 children (3.74%) with congenital heart disease but in only 6 children (0.29%) without congenital heart disease. Among the 48 children with tracheal bronchus, 45 had right-side tracheal bronchus and 3 had bilateral tracheal bronchi with heterotaxy syndrome. The diagnostic sensitivity of MDCT was 100% (48/48). MDCT is a reliable imaging technique for the diagnosis of tracheal bronchus. Our data showed that right-side tracheal bronchus was more common and bilateral tracheal bronchi usually occurred with heterotaxy syndrome. In addition, tracheal bronchus often occurred with congenital heart disease. The angle between the tracheal bronchus and the trachea is important and should be measured. (orig.)

  7. Recurred Post-intubation Tracheal Stenosis Treated with Bronchoscopic Cryotherapy

    Science.gov (United States)

    Jung, Ye-Ryung; Taek Jeong, Joon; Kyu Lee, Myoung; Kim, Sang-Ha; Joong Yong, Suk; Jeong Lee, Seok; Lee, Won-Yeon

    2016-01-01

    Post-intubation tracheal stenosis accounts for the greatest proportion of whole-cause tracheal stenosis. Treatment of post-intubation tracheal stenosis requires a multidisciplinary approach. Surgery or an endoscopic procedure can be used, depending on the type of stenosis. However, the efficacy of cryotherapy in post-intubation tracheal stenosis has not been validated. Here, we report a case of recurring post-intubation tracheal stenosis successfully treated with bronchoscopic cryotherapy that had previously been treated with surgery. In this case, cryotherapy was effective in treating web-like fibrous stenosis, without requiring more surgery. Cryotherapy can be considered as an alternative or primary treatment for post-intubation tracheal stenosis. PMID:27853078

  8. Indications and interventional options for non-resectable tracheal stenosis

    Science.gov (United States)

    Bacon, Jenny Louise; Patterson, Caroline Marie

    2014-01-01

    Non-specific presentation and normal examination findings in early disease often result in tracheal obstruction being overlooked as a diagnosis until patients present acutely. Once diagnosed, surgical options should be considered, but often patient co-morbidity necessitates other interventional options. Non-resectable tracheal stenosis can be successfully managed by interventional bronchoscopy, with therapeutic options including airway dilatation, local tissue destruction and airway stenting. There are common aspects to the management of tracheal obstruction, tracheomalacia and tracheal fistulae. This paper reviews the pathogenesis, presentation, investigation and management of tracheal disease, with a focus on tracheal obstruction and the role of endotracheal intervention in management. PMID:24624290

  9. Tracheal rupture after misplacement of Sengstaken-Blakemore tube ...

    African Journals Online (AJOL)

    The balloon were immediately deflated and a chest X-ray was performed, showing the tube in the right bronchus airway (A), so it was withdrawn. Right pneumothorax appeared and was treated with an intercostal drainage. The patient required orotracheal intubation and a CT scan was performed to show the rupture level ...

  10. Tracheal resection and anastomosis in dogs.

    Science.gov (United States)

    Lau, R E; Schwartz, A; Buergelt, C D

    1980-01-15

    Resection and end-to-end anastomosis of the trachea is a practical procedure for the correction of various forms of tracheal stenosis. Preplacing retention sutures facilitates manipulation of the trachea and rapid apposition of the tracheal ends. These same sutures then relieve tension on the primary suture line, assuring early epithelialization. Two dogs with tracheal stenosis were treated by use of this technique. Slight narrowing of the trachea was evident postoperatively in both dogs, but neither dyspnea nor coughing occurred during the follow-up period.

  11. [Successful One-lung Ventilation with a Right-sided Double-lumen Tube in a Patient with a Right Upper Tracheal Bronchus, who Underwent Left Pneumonectomy for Left Hilar Lung Cancer].

    Science.gov (United States)

    Kawagoe, Izumi; Kohchiyama, Tsukasa; Hayashida, Masakazu; Satoh, Daizoh; Suzuki, Kenji; Inada, Eiichi

    2016-06-01

    A 60-year-old male patient with left hilar lung cancer was scheduled to undergo left pneumonectomy or left sleeve lower lobectomy. Preoperative computer tomographic and bronchoscopic examinations revealed that the bronchus (B1) to the right apical segment (S1) was a tracheal bronchus (TB) originating from the trachea approximately 10 mm above the carina. Because the left main bronchus was to be dissected, a right-sided double-lumen tube (DLT) was selected to completely protect the right lung from spillage of secretions or cancer cells from the left lung. The right-sided DLT was placed so as to fit its lateral opening of the bronchial lumen to normal upper branches (B2, B3), while sacrificing ventilation of S1 with an abnormal branch (B1). However, one-lung ventilation (OLV) of the right lung could not be achieved, since a gas leakage from the opened tracheal lumen occurred, most probably due to intra-lobar micro-airway communications between S1 and S2/S3. The DLT was withdrawn until the blue bronchial cuff occluded the orifice of the TB (B1). Although the upper half of the blue bronchial cuff appeared above the tracheal carina, OLV through the two bronchial lumen openings could be achieved due to a specific, slanted doughnut shape of the blue bronchial cuff and the location of the abnormal branch (B1) approximate to the carina. Left pneumonectomy using successful OLV was completed safely without hypoxemia or hypercapnea. Our experience indicates that management of OLV for patients with a thoracheal bronchus needs special considerations of the exact location of the TB and intra-lobar micro-airway communications, in addition to types of scheduled surgical procedures.

  12. Implantation of Induced Pluripotent Stem Cell-Derived Tracheal Epithelial Cells.

    Science.gov (United States)

    Ikeda, Masakazu; Imaizumi, Mitsuyoshi; Yoshie, Susumu; Nakamura, Ryosuke; Otsuki, Koshi; Murono, Shigeyuki; Omori, Koichi

    2017-07-01

    Compared with using autologous tissue, the use of artificial materials in the regeneration of tracheal defects is minimally invasive. However, this technique requires early epithelialization on the inner side of the artificial trachea. After differentiation from induced pluripotent stem cells (iPSCs), tracheal epithelial tissues may be used to produce artificial tracheas. Herein, we aimed to demonstrate that after differentiation from fluorescent protein-labeled iPSCs, tracheal epithelial tissues survived in nude rats with tracheal defects. Red fluorescent tdTomato protein was electroporated into mouse iPSCs to produce tdTomato-labeled iPSCs. Embryoid bodies derived from these iPSCs were then cultured in differentiation medium supplemented with growth factors, followed by culture on air-liquid interfaces for further differentiation into tracheal epithelium. The cells were implanted with artificial tracheas into nude rats with tracheal defects on day 26 of cultivation. On day 7 after implantation, the tracheas were exposed and examined histologically. Tracheal epithelial tissue derived from tdTomato-labeled iPSCs survived in the tracheal defects. Moreover, immunochemical analyses showed that differentiated tissues had epithelial structures similar to those of proximal tracheal tissues. After differentiation from iPSCs, tracheal epithelial tissues survived in rat bodies, warranting the use of iPSCs for epithelial regeneration in tracheal defects.

  13. [Vocal cord paralysis associated with tracheal intubation: incidence, risk analysis, and classification of severity].

    Science.gov (United States)

    Kikura, Mutsuhito; Suzuki, Yuji; Itagaki, Taiga; Sato, Tsunehisa; Nishino, Junko

    2015-01-01

    Vocal cord paralysis after tracheal intubation is rare. It causes severe hoarseness and aspiration, and delays recovery and discharge. Arytenoid cartilage dislocation and recurrent nerve paralysis are main causes of vocal cord paralysis. Physical stimulation of the tracheal tube as well as patient and surgical characteristics also contribute. Vocal cord paralysis occurs in 1 (0.07%) of 1,500 general surgery patients and on the left side in 70% of cases. It is associated with surgery/anesthesia time (two-fold, 3-6 hours; 15-fold, over 6 hours), age (three-fold, over 50 years), and diabetes mellitus or hypertension (two-fold). Symptoms resolve in 2-3 months. In adult cardiovascular surgery, vocal cord paralysis occurs in 1 (0.7-2%) of 50-100 cardiac surgery patients and 1 (8.6-32%) of 3-10 thoracic aortic surgery patients. In pediatric cardiac surgery, vocal cord paralysis occurs in 1 (0.1-0.5%) of 200-1,000 patients. We classified the severity of vocal cord paralysis as I, severe hoarseness; II, aspiration or dysphagia; and III, bilateral vocal cord paralysis, aspiration pneumonia, or the need for tracheal re-intubation or tracheotomy. We discuss the importance of informed consent for the patient and family.

  14. Pediatric cuffed endotracheal tubes

    Directory of Open Access Journals (Sweden)

    Neerja Bhardwaj

    2013-01-01

    Full Text Available Endotracheal intubation in children is usually performed utilizing uncuffed endotracheal tubes for conduct of anesthesia as well as for prolonged ventilation in critical care units. However, uncuffed tubes may require multiple changes to avoid excessive air leak, with subsequent environmental pollution making the technique uneconomical. In addition, monitoring of ventilatory parameters, exhaled volumes, and end-expiratory gases may be unreliable. All these problems can be avoided by use of cuffed endotracheal tubes. Besides, cuffed endotracheal tubes may be of advantage in special situations like laparoscopic surgery and in surgical conditions at risk of aspiration. Magnetic resonance imaging (MRI scans in children have found the narrowest portion of larynx at rima glottides. Cuffed endotracheal tubes, therefore, will form a complete seal with low cuff pressure of <15 cm H 2 O without any increase in airway complications. Till recently, the use of cuffed endotracheal tubes was limited by variations in the tube design marketed by different manufacturers. The introduction of a new cuffed endotracheal tube in the market with improved tracheal sealing characteristics may encourage increased safe use of these tubes in clinical practice. A literature search using search words "cuffed endotracheal tube" and "children" from 1980 to January 2012 in PUBMED was conducted. Based on the search, the advantages and potential benefits of cuffed ETT are reviewed in this article.

  15. Immediate, short‐, and long‐term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome

    Science.gov (United States)

    Raske, Matthew; Berent, Allyson C.; McDougall, Renee; Lamb, Kenneth

    2018-01-01

    Background Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Objectives Identify immediate post‐stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate‐, short‐, and long‐term periods, and evaluate inter‐observer reliability of radiographic measurements. Animals Fifty client‐owned dogs. Methods Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post‐stent placement radiographic follow‐up times. Radiographs were used to obtain pre‐stent tracheal measurements and post‐stent placement measurements. Results Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Ultimate mean follow‐up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long‐term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short‐, or long‐term periods. Good inter‐observer agreement of radiographic measurements was found among observers of variable experience level. Conclusions and Clinical Importance Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. PMID:29460368

  16. Tracheal resections and anastomosis for benign tracheal stricture. A seven-year experience in a single tertiary institute

    Directory of Open Access Journals (Sweden)

    Ahmed Mostafa

    2017-09-01

    Conclusions: TRA proved to be a safe and reliable solution for post-intubation tracheal stenosis. This procedure should be considered first in developing countries where there is frequent rush for tracheostomies and tracheal stenting. Quality of life improved dramatically following this definitive surgery.

  17. CO2 driven endotracheal tube cuff control in critically ill patients: A randomized controlled study.

    Science.gov (United States)

    De Pascale, Gennaro; Pennisi, Mariano Alberto; Vallecoccia, Maria Sole; Bello, Giuseppe; Maviglia, Riccardo; Montini, Luca; Di Gravio, Valentina; Cutuli, Salvatore Lucio; Conti, Giorgio; Antonelli, Massimo

    2017-01-01

    To determine the safety and clinical efficacy of an innovative integrated airway system (AnapnoGuard™ 100 system) that continuously monitors and controls the cuff pressure (Pcuff), while facilitating the aspiration of subglottic secretions (SS). This was a prospective, single centre, open-label, randomized, controlled feasibility and safety trial. The primary endpoint of the study was the rate of device related adverse events (AE) and serious AE (SAE) as a result of using AnapnoGuard (AG) 100 during mechanical ventilation. Secondary endpoints were: (1) mechanical complications rate (2) ICU staff satisfaction; (3) VAP occurrence; (4) length of mechanical ventilation; (5) length of Intensive Care Unit stay and mortality; (6) volume of evacuated subglottic secretions. Sixty patients were randomized to be intubated with the AG endotracheal-tube (ETT) and connected to the AG 100 system allowing Pcuff adjustment and SS aspiration; or with an ETT combined with SS drainage and Pcuff controlled manually. No difference in adverse events rate was identified between the groups. The use of AG system was associated with a significantly higher incidence of Pcuff determinations in the safety range (97.3% vs. 71%; paspirated SS secretions: (192.0[64-413] ml vs. 150[50-200], p = 0.19 (total)); (57.8[20-88.7] ml vs. 50[18.7-62] ml, p = 0.11 (daily)). No inter-group difference was detected using AG system vs. controls in terms of post-extubation throat pain level (0 [0-2] vs. 0 [0-3]; p = 0.7), hoarseness (42.9% vs. 75%; p = 0.55) and tracheal mucosa oedema (16.7% vs. 10%; p = 0.65). Patients enrolled in the AG group had a trend to reduced VAP risk of ventilator-associated pneumonia(VAP) (14.8% vs. 40%; p = 0.06), which were more frequently monomicrobial (25% vs. 70%; p = 0.03). No statistically significant difference was observed in duration of mechanical ventilation, ICU stay, and mortality. The use AG 100 system and AG tube in critically ill intubated patients is safe and

  18. Synchrotron imaging of the grasshopper tracheal system : morphological and physiological components of tracheal hypermetry.

    Energy Technology Data Exchange (ETDEWEB)

    Greenlee, K. J.; Henry, J. R.; Kirkton, S. D.; Westneat, M. W.; Fezzaa, K.; Lee, W.; Harrison, J. F.; North Dakota State Univ.; Arizona State Univ.; Union Coll.; Field Museum of Natural History

    2009-11-01

    As grasshoppers increase in size during ontogeny, they have mass specifically greater whole body tracheal and tidal volumes and ventilation than predicted by an isometric relationship with body mass and body volume. However, the morphological and physiological bases to this respiratory hypermetry are unknown. In this study, we use synchrotron imaging to demonstrate that tracheal hypermetry in developing grasshoppers (Schistocerca americana) is due to increases in air sacs and tracheae and occurs in all three body segments, providing evidence against the hypothesis that hypermetry is due to gaining flight ability. We also assessed the scaling of air sac structure and function by assessing volume changes of focal abdominal air sacs. Ventilatory frequencies increased in larger animals during hypoxia (5% O{sub 2}) but did not scale in normoxia. For grasshoppers in normoxia, inflated and deflated air sac volumes and ventilation scaled hypermetrically. During hypoxia (5% O{sub 2}), many grasshoppers compressed air sacs nearly completely regardless of body size, and air sac volumes scaled isometrically. Together, these results demonstrate that whole body tracheal hypermetry and enhanced ventilation in larger/older grasshoppers are primarily due to proportionally larger air sacs and higher ventilation frequencies in larger animals during hypoxia. Prior studies showed reduced whole body tracheal volumes and tidal volume in late-stage grasshoppers, suggesting that tissue growth compresses air sacs. In contrast, we found that inflated volumes, percent volume changes, and ventilation were identical in abdominal air sacs of late-stage fifth instar and early-stage animals, suggesting that decreasing volume of the tracheal system later in the instar occurs in other body regions that have harder exoskeleton.

  19. Synchrotron imaging of the grasshopper tracheal system: morphological and physiological components of tracheal hypermetry

    International Nuclear Information System (INIS)

    Greenlee, K.J.; Henry, J.R.; Kirkton, S.D.; Westneat, M.W.; Fezzaa, K.; Lee, W.; Harrison, J.F.

    2009-01-01

    As grasshoppers increase in size during ontogeny, they have mass specifically greater whole body tracheal and tidal volumes and ventilation than predicted by an isometric relationship with body mass and body volume. However, the morphological and physiological bases to this respiratory hypermetry are unknown. In this study, we use synchrotron imaging to demonstrate that tracheal hypermetry in developing grasshoppers (Schistocerca americana) is due to increases in air sacs and tracheae and occurs in all three body segments, providing evidence against the hypothesis that hypermetry is due to gaining flight ability. We also assessed the scaling of air sac structure and function by assessing volume changes of focal abdominal air sacs. Ventilatory frequencies increased in larger animals during hypoxia (5% O 2 ) but did not scale in normoxia. For grasshoppers in normoxia, inflated and deflated air sac volumes and ventilation scaled hypermetrically. During hypoxia (5% O 2 ), many grasshoppers compressed air sacs nearly completely regardless of body size, and air sac volumes scaled isometrically. Together, these results demonstrate that whole body tracheal hypermetry and enhanced ventilation in larger/older grasshoppers are primarily due to proportionally larger air sacs and higher ventilation frequencies in larger animals during hypoxia. Prior studies showed reduced whole body tracheal volumes and tidal volume in late-stage grasshoppers, suggesting that tissue growth compresses air sacs. In contrast, we found that inflated volumes, percent volume changes, and ventilation were identical in abdominal air sacs of late-stage fifth instar and early-stage animals, suggesting that decreasing volume of the tracheal system later in the instar occurs in other body regions that have harder exoskeleton.

  20. Endotracheal tube cuff pressure monitoring during neurosurgery - Manual vs. automatic method

    Directory of Open Access Journals (Sweden)

    Mukul Kumar Jain

    2011-01-01

    Full Text Available Background: Inflation and assessment of the endotracheal tube cuff pressure is often not appreciated as a critical aspect of endotracheal intubation. Appropriate endotracheal tube cuff pressure, endotracheal intubation seals the airway to prevent aspiration and provides for positive-pressure ventilation without air leak. Materials and Methods: Correlations between manual methods of assessing the pressure by an experienced anesthesiologists and assessment with maintenance of the pressure within the normal range by the automated pressure controller device were studied in 100 patients divided into two groups. In Group M, endotracheal tube cuff was inflated manually by a trained anesthesiologist and checked for its pressure hourly by cuff pressure monitor till the end of surgery. In Group C, endotracheal tube cuff was inflated by automated cuff pressure controller and pressure was maintained at 25-cm H 2 O throughout the surgeries. Repeated measure ANOVA was applied. Results: Repeated measure ANOVA results showed that average of endotracheal tube cuff pressure of 50 patients taken at seven different points is significantly different (F-value: 171.102, P-value: 0.000. Bonferroni correction test shows that average of endotracheal tube cuff pressure in all six groups are significantly different from constant group (P = 0.000. No case of laryngomalacia, tracheomalacia, tracheal stenosis, tracheoesophageal fistula or aspiration pneumonitis was observed. Conclusions: Endotracheal tube cuff pressure was significantly high when endotracheal tube cuff was inflated manually. The known complications of high endotracheal tube cuff pressure can be avoided if the cuff pressure controller device is used and manual methods cannot be relied upon for keeping the pressure within the recommended levels.

  1. Corrugated thimble tube for controlling control rod descent in nuclear reactor

    International Nuclear Information System (INIS)

    Luetzow, H.J.

    1981-01-01

    A thimble tube construction is described which will provide a controlled descent for a control rod while minimizing the reaction forces which must be absorbed by the thimble tube and reducing the possibility that a foreign particle could interfere with the free descent of a control rod. A thimble tube is formed with helically-corrugate internal walls which cooperate with a control rod contained in the tube in an emergency situation to provide a progressively-increasing hydraulic restraining force as each adjacent corrugation is encountered

  2. Evaluation of a smartphone camera system to enable visualization and image transmission to aid tracheal intubation with the Airtraq(®) laryngoscope.

    Science.gov (United States)

    Lee, Delice Weishan; Thampi, Swapna; Yap, Eric Peng Huat; Liu, Eugene Hern Choon

    2016-06-01

    Using three-dimensional printing, we produced adaptors to attach a smartphone with camera to the eyepiece of the Airtraq(®) laryngoscope. This low-cost system enabled a team to simultaneously view the laryngoscopy process on the smartphone screen, and also enabled image transmission. We compared the Airtraq(®) with the smartphone Airtraq(®) system in a crossover study of trainee anesthesiologists performing tracheal intubation in a manikin. We also evaluated the smartphone Airtraq(®) system for laryngoscopy and tracheal intubation in 30 patients, including image transmission to and communication with a remote instructor. In the manikin study, the smartphone Airtraq(®) system enabled instruction where both trainee and instructor could view the larynx simultaneously, and did not substantially increase the time required for intubation. In the patient study, we were able to view the larynx in all 30 patients, and the remote instructor was able to receive the images and to respond on correctness of laryngoscopy and tracheal tube placement. Tracheal intubation was successful within 90s in 19 (63 %) patients. In conclusion, use of a smartphone with the Airtraq(®) may facilitate instruction and communication of laryngoscopy with the Airtraq(®), overcoming some of its limitations.

  3. Immediate, short-, and long-term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome.

    Science.gov (United States)

    Raske, Matthew; Weisse, Chick; Berent, Allyson C; McDougall, Renee; Lamb, Kenneth

    2018-03-01

    Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Identify immediate post-stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate-, short-, and long-term periods, and evaluate inter-observer reliability of radiographic measurements. Fifty client-owned dogs. Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post-stent placement radiographic follow-up times. Radiographs were used to obtain pre-stent tracheal measurements and post-stent placement measurements. Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Ultimate mean follow-up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long-term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short-, or long-term periods. Good inter-observer agreement of radiographic measurements was found among observers of variable experience level. Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  4. Metallic stent implantation in the treatment of malignant tracheal stenosis under general anaesthesia

    International Nuclear Information System (INIS)

    Bai Xuming; Jin Yong; Xie Hong; Cheng Long; Gu Xingshi; Chang Liuhui

    2012-01-01

    Objective: To evaluate the safety and feasibility of the tracheal stent implantation for treatment of malignant tracheal stenosis under general anaesthesia. Methods: Eighteen patients with malignant tracheal stenosis underwent preoperative 64-slice spiral CT scan and airway reconstruction. The stenotic sites were located in main tracheal trunk (5 patients), in right main bronchus (1 patient), in trachea and left main bronchus (4 patients), in trachea and right main bronchus (3 patients), in main tracheal trunk and bilateral main bronchus (5 patients). The degree of stenosis was rated 51% to 70% in 7 cases, 71% to 90% in 11 cases. All patients, 17 patients of ASA grade Ⅳ and 1 patient of grade Ⅲ, presented with severe dyspnea. Under general anaesthesia, implantation of metallic stent was performed through the sputum aspiration hole of the connecting tubing with DSA guidance. The NBP, ECG, RR, SaO 2 of the patients were recorded and compared with t test during the entire procedure. At the end of the procedure, relief of dyspnea, complications related to anesthesia and operation were recorded. Results: The success rate of stent placement was 18/18, and dyspnea was significantly relived in all patients. Slightly bloody sputum occurred in 7 cases. The stent was obstructed by sputum in 1 case,and the patient was treated with medication. There were no severe complications. The operative course were rated 11 to 9 in 17 cases, and 6 to 8 in 1 case. All 18 patients were cooperative during the procedure. Sixteen patients rated the procedure as very comfortable and 2 rated the procedure as comfortable. Respiratory rate (RR) and heart rate (HR) decreased in all patients after the operation [(37.1 ± 2.8)/min and (106.5 ± 14.2) bpm before the operation respectively, (18.6 ± 1.4)/min and (73.2 ± 7.6) bpm after the operation respectively], t=17.81 and 3.80, P<0.01. Pulse oxygen saturation (SaO 2 ) during the operation [(91.2 ± 1.8)%]increased [(76.3 ± 8.6 )% before the

  5. EFFECT OF INTRACUFF MEDIA-ALKALINISED LIGNOCAINE, SALINE, AND AIR ON ENDOTRACHEAL TUBE INDUCED EMERGENCE PHENOMENA: A RANDOMIZED CONTROLLED STUDY

    Directory of Open Access Journals (Sweden)

    Indu S

    2016-07-01

    Full Text Available CONTEXT Emergence from general anaesthesia is associated with post extubation cough, hoarseness, sore throat, and dysphagia, which may affect the smoothness of extubation. Prophylactic interventions have been studied to reduce these tracheal morbidities with varying results. AIMS To compare the efficacy of air, alkalinised lignocaine and saline in maintaining intracuff pressure and reducing postoperative cough (PEC and sore throat (POST. SETTINGS AND DESIGN A randomised controlled study conducted in a teaching hospital. METHODS AND MATERIALS 105 patients scheduled for elective surgeries were randomly allocated into groups of 35 each. The endotracheal tube (ETT cuffs were inflated with air, alkalinised lignocaine, or saline. The intracuff pressure (ICP was initially set to 25-30 cm of H2O; measured every 30 minutes and before extubation; the minimum volume for occlusion (MOV noted. The incidence PEC and POST were monitored. STATISTICAL ANALYSIS Data analysed using Chi-square test, Fisher’s exact test; Bonferroni method allowed multiple comparisons. A p value <0.05 was considered significant. RESULTS Pre-lubricated ETT cuff inflation with liquid media maintained an acceptable ICP. Saline and alkalinised lignocaine were effective in reducing PEC and POST. Alkalinised lignocaine provided smoother extubation and fared better in the early postoperative period. CONCLUSIONS Pre-lubricated ETT cuffs with liquid media reduced PEC and POST. Alkalinised lignocaine showed better profile than saline. Optimum ICP reduces tracheal morbidity.

  6. Ultrasonography for Proper Endotracheal Tube Placement Confirmation in Out-of-hospital Cardiac Arrest Patients: Two-center Experience

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Conclusion: Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during cardiopulmonary resuscitation without the need for interruption of chest compression.

  7. Severe hypoxaemia in field-anaesthetised white rhinoceros (Ceratotherium simum and effects of using tracheal insufflation of oxygen

    Directory of Open Access Journals (Sweden)

    M. Bush

    2004-06-01

    Full Text Available White rhinoceros anaesthetised with etorphine and azaperone combination develop adverse physiological changes including hypoxia, hypercapnia, acidosis, tachycardia and hypertension. These changes are more marked in field-anaesthetised rhinoceros. This study was designed to develop a technique to improve safety for field-anaesthetised white rhinoceros by tracheal intubation and oxygen insufflation. Twenty-five free-ranging white rhinoceros were anaesthetised with an etorphine and azaperone combination for translocation or placing microchips in their horns. Once anaesthetised the rhinoceros were monitored prior to crating for transportation or during microchip placement. Physiological measurements included heart and respiratory rate, blood pressure and arterial blood gas samples. Eighteen rhinoceros were intubated using an equine nasogastric tube passed nasally into the trachea and monitored before and after tracheal insufflation with oxygen. Seven rhinoceros were not intubated or insufflated with oxygen and served as controls. All anaesthetised rhinoceros were initially hypoxaemic (percentage arterial haemoglobin oxygen saturation (% O2Sa = 49 % + 16 (mean + SD and PaO2 = 4.666 + 1.200 kPa (35 + 9 mm Hg, hypercapnic (PaCO2 = 8.265 + 1.600 kPa (62 + 12 mm Hg and acidaemic (pHa = 7.171 + 0.073 . Base excess was -6.7 + 3.9 mmol/ℓ, indicating a mild to moderate metabolic acidosis. The rhinoceros were also hypertensive (systolic blood pressure = 21.861 + 5.465 kPa (164 + 41 mm Hg and tachycardic (HR = 107 + 31/min. Following nasal tracheal intubation and insufflation, the % O2Sa and PaO2 increased while blood pHa and PaCO2 remained unchanged.Tracheal intubation via the nose is not difficult, and when oxygen is insufflated, the PaO2 and the % O2Sa increases, markedly improving the safety of anaesthesia, but this technique does not correct the hypercapnoea or acidosis. After regaining their feet following reversal of the anaesthesia, the animals

  8. Snake Envenomation Causing Distant Tracheal Myonecrosis

    Directory of Open Access Journals (Sweden)

    Amina Khimani

    2013-01-01

    Full Text Available Snakebites are often believed to be poisonous. However, this is not always the case. In fact, each bite differs from snake to snake, depending on if the snake is poisonous and if there is envenomation. Venom in pit viper snakebites is often associated with local necrosis. The abundant literature selections and research articles justify local myonecrosis due to envenomation, but there is not much in the literature regarding myonecrosis at a site distant from the snakebite. We hereby present a case of a 42-year-old man who was transferred to our emergency department after a rattlesnake bit him twice. The patient, besides developing local myonecrosis at the site of the snakebite, developed necrosis of the scrotum as well as tracheal pressure myonecrosis at the site of the endotracheal tube balloon. In this review, we will attempt to discuss the myonecrosis pathophysiology and management related to the rattle snakebite.

  9. Tracheal web

    International Nuclear Information System (INIS)

    Legasto, A.C.; Haller, J.O.; Giusti, R.J.

    2004-01-01

    Congenital tracheal web is a rare entity often misdiagnosed as refractory asthma. Clinical suspicion based on patient history, examination, and pulmonary function tests should lead to its consideration. Bronchoscopy combined with CT imaging and multiplanar reconstruction is an accepted, highly sensitive means of diagnosis. (orig.)

  10. Effectiveness of the endotracheal tube cuff on the trachea: physical and mechanical aspects

    Directory of Open Access Journals (Sweden)

    Maira Soliani Del Negro

    2014-12-01

    Full Text Available Introduction: The inflation pressure of the endotracheal tube cuff can cause ischemia of the tracheal mucosa at high pressures; thus, it can cause important tracheal morbidity and tracheal microaspiration of the oropharyngeal secretion, or it can even cause pneumonia associated with mechanical ventilation if the pressure of the cuff is insufficient. Objective: In order to investigate the effectiveness of the RUSCH® 7.5 mm endotracheal tube cuff, this study was designed to investigate the physical and mechanical aspects of the cuff in contact with the trachea. Methods: For this end, we developed an in vitro experimental model to assess the flow of dye (methylene blue by the inflated cuff on the wall of the artificial material. We also designed an in vivo study with 12 Large White pigs under endotracheal intubation. We instilled the same dye in the oral cavity of the animals, and we analyzed the presence or not of leakage in the trachea after the region of the cuff after their deaths (animal sacrifice. All cuffs were inflated at the pressure of 30 cmH2O. Results: We observed the passage of fluids through the cuff in all in vitro and in vivo experimental models. Conclusion: We conclude that, as well as several other cuff models in the literature, the RUSCH® 7.5 mm tube cuffs are also not able to completely seal the trachea and thus prevent aspiration of oropharyngeal secretions. Other prevention measures should be taken.

  11. Management of embedded metallic stents used in the treatment of grades III and IV subglottic, and upper tracheal stenosis in adults.

    Science.gov (United States)

    Sendi, Khalil; Al-Khatib, Talal; Ahmed, Duha G; Tonkul, Al-Baraa

    2014-11-01

    The aim of this study was to evaluate the post-operative complications of using balloon-expandable metallic stents in treatment of benign, major subglottic and tracheal stenosis in adult patients whom conventional therapy has failed and to demonstrate how to deal with these complications in the long run. A retrospective review of five cases; adlut patiets with benign, major subglottic and upper tracheal stenosis whom were treated with balloon expandable metallic stents at King Abdulaziz University Hospital, in the years between 2008 and 2013. Granulation tissue formed in five of the four cases and restenosis occurred. Other complications encountered were stent infection and dislodgment. The complications were managed by removing the stents surgically via a laryngofissure incision and required the placement of a Montgomery T-tube. Managing the restenosis due to granulation tissue formation around the metallic stents is best achieved by removing the embedded metallic stents surgically via open technique and then by placement of a Montgomery T-tube as a bridging option to successful decannulation. Open surgical procedures remain the mainstay treatment for advanced airway stenosis.

  12. A comparison of simple continuous versus simple interrupted suture patterns for tracheal anastomosis after large-segment tracheal resection in dogs.

    Science.gov (United States)

    Fingland, R B; Layton, C I; Kennedy, G A; Galland, J C

    1995-01-01

    Two suture techniques for tracheal anastomosis after large-segment tracheal resection were compared. Eight cartilages were resected from the trachea of each of 12 dogs; anastomoses with 4-0 polydioxanone suture were created using a simple continuous suture technique in six dogs and a simple interrupted suture technique in six dogs. Surgical time was shorter but apposition of tracheal segments at the time of surgery was less precise with the simple continuous suture technique. The dogs were evaluated for 150 days after surgery. Clinical abnormalities after tracheal resection and anastomosis were not observed. Percent dorsoventral luminal stenosis was calculated by measuring the tracheal lumen diameter on lateral cervical radiographs. Percent luminal stenosis was calculated planimetrically using a computerized digitizing tablet. Anastomotic stenosis was mild in all dogs; however, the mean percent.luminal stenosis determined planimetrically was significantly greater for dogs that had the simple continuous suture technique. Planimetric measurements of cross-sectional area made before and after formalin fixation were not significantly different. Radiographic determination of percent dorsoventral luminal stenosis was a poor predictor of diminution of cross-sectional area determined planimetrically.

  13. Control rod guide tube cleaning device

    International Nuclear Information System (INIS)

    Tsuji, Tadashi; Shiota, Yoshiaki.

    1990-01-01

    Since there was no exclusive device for cleaning control rods, no effective cleaning could not be conducted and there was a possibility that obstacles may not be recovered. Then, there are disposed a first pump for supplying pressurized water, a spray nozzle for forming a swirling flow in a control rod guide tube, a second pump for pressurizing water introduced by a sucking pipeline and a collecting device for recovering obstacles intruding to water from the second pump. The pressurized water supplied from the first pump is introduced to a head passing through a blowing pipe and jetted from the spray nozzle to the control rod guide tube. In this case, a swirling stream occurs and obstacles in the control guide tube are mixed into water. The water containing the obstacles passes from the sucking port through a pipeline, introduced to the second pump and recovered to the collecting device. Since there is no water staying portion upon cleaning operation, the obstacles accumulating over the entire region of the bottom of the guide tube can be recovered reliably and efficiently. (N.H.)

  14. Tube Model Predictive Control with an Auxiliary Sliding Mode Controller

    Directory of Open Access Journals (Sweden)

    Miodrag Spasic

    2016-07-01

    Full Text Available This paper studies Tube Model Predictive Control (MPC with a Sliding Mode Controller (SMC as an auxiliary controller. It is shown how to calculate the tube widths under SMC control, and thus how much the constraints of the nominal MPC have to be tightened in order to achieve robust stability and constraint fulfillment. The analysis avoids the assumption of infinitely fast switching in the SMC controller.

  15. Effects of tracheal orientation on development of ventilator-associated pneumonia: an experimental study.

    Science.gov (United States)

    Zanella, Alberto; Cressoni, Massimo; Epp, Myra; Hoffmann, Viktoria; Stylianou, Mario; Kolobow, Theodor

    2012-04-01

    Orientation of the trachea and tracheal tube below horizontal may prevent aspiration of oropharyngeal secretions into the lungs, which is a pivotal pathway in the pathogenesis of ventilator-associated pneumonia (VAP). The incidence of VAP was evaluated in swine with orientation of trachea and tracheal tube above horizontal (model of semirecumbent position, currently recommended in patients) and below horizontal. Twenty-six mini-pigs were randomized into four groups: (A) eight mechanically ventilated with orientation of trachea 45° above horizontal for 72 h. In the remaining groups (B, C, D) the trachea was oriented 10° below horizontal, with (B) six mechanically ventilated for 72 h, (C) six mechanically ventilated for 72 h with enteral feeding, and (D) six mechanically ventilated for 168 h with enteral feeding. At the end of the study period, all pigs were sacrificed and the clinical diagnosis of VAP was microbiologically evaluated. No antibiotics were administered. All eight pigs kept orientated with the trachea 45° above horizontal developed VAP and respiratory failure (PaO(2)/F(i)O(2) = 132 ± 139 mmHg) with a median of 5.5 pulmonary lobes out of 6 colonized with average colonization of 9.3 × 10(7) CFU/g. None of the 18 pigs kept oriented with the trachea below horizontal developed VAP; 16 had sterile lungs, while 2, ventilated for 7 days, developed a low level of colonization. Orientation of the trachea above horizontal was uniformly associated with VAP and respiratory failure; positioning the trachea below horizontal consistently prevented development of VAP.

  16. Effects of premedication with oral gabapentin on intraocular pressure changes following tracheal intubation in clinically normal dogs.

    Science.gov (United States)

    Trbolova, Alexandra; Ghaffari, Masoud Selk; Capik, Igor

    2017-09-19

    Gabapentin is an antiepileptic drug widely approved as an add-on therapy for epilepsy treatment in human and dogs. There is a clinical impression that gabapentin is a suitable drug which attenuates the IOP elevation associated with tracheal intubation in humans. The present study performed to determine the effects of oral gabapentin on intraocular pressure (IOP) changes following tracheal intubation in dogs. Twenty adult healthy dogs were randomly assigned to treatment (n = 10) and control (n = 10) groups. Dogs in the treatment group received oral gabapentin (50 mg/kg) 2 h before induction of anesthesia and dogs in the control group received oral gelatin capsule placebo at the same time. The dogs were anesthetized with propofol 6 mg/kg, and anesthesia was maintained with a constant infusion of 0.2 mg/kg/min of propofol for 20 min. IOP were measured immediately before induction and then repeated immediately after induction, as well as 5 min, 10 min and 15 min following tracheal intubation in both groups. IOP was significantly higher immediately after induction, and 5 min after tracheal intubation when compared with IOP reading before induction in the control group. There was no statistically significant change in IOPs immediately after induction, and 5 min after tracheal intubation in comparison to the values before induction in the treatment group. Based on the findings of this study, preanesthetic oral administration of gabapentin significantly prevents an increase in the IOP associated with tracheal intubation in dogs anesthetized with propofol.

  17. Homologous tracheal transplantation with grafts previously exposed to high doses of gamma radiation in dogs without immunosuppressive agents

    International Nuclear Information System (INIS)

    Yokomise, Hiroyasu; Inui, Kenji; Kure, Toshio; Wada, Hiromi; Itomi, Shigeki

    1993-01-01

    The study was designed to determine whether previous high doses irradiation of gamma radiation would contribute to tracheal transplantation with no use of immunosuppressive agents. Twenty mongrel dogs were used as experimental animals. Five rings of thoracic tracheas, which were extracted from recipients, were exposed to 20000, 50000, or 100000 cGy in each 5 dogs. Five other non-irradiated dogs served as controls. Irradiated tracheal grafts were transplanted and covered with pedicled omentum. After transplantation, no immunosuppressive agents were given to dogs. All dogs in the control group died of tracheal stenosis due to graft-host rejection within one month. All but one long-term survivor died of tracheal stenosis, as well, in both the 20000 cGy and 50000 cGy groups. In the 100000 cGy group, grafts became viable in 4 dogs, and three of these survived one year or more. In conclusion, previous irradiation with high doses of 100000 cGy allowed homologous tracheal transplantation even when no immunosuppressive agents are given. (N.K.)

  18. Bronchoscopic Treatment in the Management of Benign Tracheal Stenosis: Choices for Simple and Complex Tracheal Stenosis.

    Science.gov (United States)

    Dalar, Levent; Karasulu, Levent; Abul, Yasin; Özdemir, Cengiz; Sökücü, Sinem Nedime; Tarhan, Merve; Altin, Sedat

    2016-04-01

    Bronchoscopic treatment is 1 of the treatment choices for both palliative and definitive treatment of benign tracheal stenosis. There is no consensus on the management of these patients, however, especially patients having complex stenoses. The aim of the present study was to assess, in the largest group of patients with complex stenoses yet reported, which types of tracheal stenosis are amenable to optimal management by bronchoscopic treatment. The present study was a retrospective cohort study including 132 consecutive patients with benign tracheal stenoses diagnosed between August 2005 and January 2013. The mean age of the study population was 52 ± 18 years; 62 (47%) were women and 70 (53%) were men. Their lesions were classified as simple and complex stenoses. Simple stenoses (n = 6) were treated with 12 rigid and flexible bronchoscopic procedures (mean of 2 per patient); 5 stents were placed. The total success rate was 100%. Among the 124 complex stenoses, 4 were treated directly with surgical intervention. In total, 481 rigid and 487 flexible bronchoscopic procedures were performed in these patients. In this group, the success rate was 69.8%. From the present study, we propose that after accurate classification, interventional bronchoscopic management may have an important role in the treatment of benign tracheal stenosis. Bronchoscopic treatment should be considered as first-line therapy for simple stenoses, whereas complex stenoses need a multidisciplinary approach and often require surgical intervention. However, bronchoscopic treatment may be a valid conservative approach in the management of patients with complex tracheal stenosis who are not eligible for operative treatment. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Post intubation tracheal stenosis in children

    Directory of Open Access Journals (Sweden)

    Marco Caruselli

    2014-12-01

    Full Text Available Many authors have reported that tracheal stenosis is a complication that can follow tracheal intubation in both adults and children. The symptoms, when they do appear, can be confused with asthma, with subsequent treatment providing only mild and inconsistent relief. We report here the case of an 8 year old girl admitted to our hospital for whooping cough that was not responding to therapy.

  20. CO2 driven endotracheal tube cuff control in critically ill patients: A randomized controlled study.

    Directory of Open Access Journals (Sweden)

    Gennaro De Pascale

    Full Text Available To determine the safety and clinical efficacy of an innovative integrated airway system (AnapnoGuard™ 100 system that continuously monitors and controls the cuff pressure (Pcuff, while facilitating the aspiration of subglottic secretions (SS.This was a prospective, single centre, open-label, randomized, controlled feasibility and safety trial. The primary endpoint of the study was the rate of device related adverse events (AE and serious AE (SAE as a result of using AnapnoGuard (AG 100 during mechanical ventilation. Secondary endpoints were: (1 mechanical complications rate (2 ICU staff satisfaction; (3 VAP occurrence; (4 length of mechanical ventilation; (5 length of Intensive Care Unit stay and mortality; (6 volume of evacuated subglottic secretions. Sixty patients were randomized to be intubated with the AG endotracheal-tube (ETT and connected to the AG 100 system allowing Pcuff adjustment and SS aspiration; or with an ETT combined with SS drainage and Pcuff controlled manually.No difference in adverse events rate was identified between the groups. The use of AG system was associated with a significantly higher incidence of Pcuff determinations in the safety range (97.3% vs. 71%; p<0.01 and a trend to a greater volume of aspirated SS secretions: (192.0[64-413] ml vs. 150[50-200], p = 0.19 (total; (57.8[20-88.7] ml vs. 50[18.7-62] ml, p = 0.11 (daily. No inter-group difference was detected using AG system vs. controls in terms of post-extubation throat pain level (0 [0-2] vs. 0 [0-3]; p = 0.7, hoarseness (42.9% vs. 75%; p = 0.55 and tracheal mucosa oedema (16.7% vs. 10%; p = 0.65. Patients enrolled in the AG group had a trend to reduced VAP risk of ventilator-associated pneumonia(VAP (14.8% vs. 40%; p = 0.06, which were more frequently monomicrobial (25% vs. 70%; p = 0.03. No statistically significant difference was observed in duration of mechanical ventilation, ICU stay, and mortality.The use AG 100 system and AG tube in critically ill

  1. Control rod guide tube of nuclear reactor

    International Nuclear Information System (INIS)

    Suda, Yoshitaka; Ito, Kenji; Matsumoto, Kunio.

    1994-01-01

    Zr having a residual tensile stress of 3 to 10kg/mm 2 in a circumferential direction is used for the main ingredient of a control guide tube of a nuclear reactor. For this purpose, an appropriate correction method such as a roll-correction, tension-correction and press-correction method is applied to an existent Zr-base alloy tube with no substantial residual stress. If the residual tensile stress in the circumferential direction is smaller than 3kg/mm 2 , an effect sufficient to suppress irradiation growth is not obtainable, if it exceeds 10kg/mm 2 , dimensional changes, cracks or the like occurs locally since the wall thickness of the control rod guide tube is small and, accordingly, this often results in failed products as the control guide tube. (N.H.)

  2. Non-destructive controls in the steel tube industry

    International Nuclear Information System (INIS)

    Mondot, J.

    1978-01-01

    The main non-destructive control methods in the tube industry are reviewed: eddy currents, particularly well adapted to small tubes; magnetoscopic testing for weldless tubes; ultrasonic waves widely used for thick weldless tubes and weldings; radiography, to examine tube ends and the known questionable zones; measure of diameters by laser [fr

  3. Bronchial lumen is the safer route for an airway exchange catheter in double-lumen tube replacement: preventable complication in airway management for thoracic surgery.

    Science.gov (United States)

    Wu, Hsiang-Ling; Tai, Ying-Hsuan; Wei, Ling-Fang; Cheng, Hung-Wei; Ho, Chiu-Ming

    2017-10-01

    There is no current consensus on which lumen an airway exchange catheter (AEC) should be passed through in double-lumen endotracheal tube (DLT) to exchange for a single-lumen endotracheal tube (SLT) after thoracic surgery. We report an unusual case to provide possible solution on this issue. A 71-year-old man with lung adenocarcinoma had an event of a broken exchange catheter used during a DLT replacement with a SLT, after a video-assisted thoracic surgery. The exchange catheter was impinged at the distal tracheal lumen and snapped during manipulation. All three segments of the catheter were retrieved without further airway compromises. Placement of airway tube exchanger into the tracheal lumen of double-lumen tube is a potential contributing factor of the unusual complication. We suggest an exchange catheter be inserted into the bronchial lumen in optimal depth with the adjunct of video laryngoscope, as the safe method for double-lumen tube exchange.

  4. Effects of tracheal occlusion with retinoic acid administration on normal lung development.

    Science.gov (United States)

    Delabaere, Amélie; Marceau, Geoffroy; Coste, Karen; Blanchon, Loïc; Déchelotte, Pierre-Jean; Blanc, Pierre; Sapin, Vincent; Gallot, Denis

    2017-05-01

    Tracheal occlusion (TO) is an investigational therapy for severe congenital diaphragmatic hernia that decreases pulmonary hypoplasia, but sustained TO also induces deficient surfactant synthesis. Intramuscular maternal administration of retinoic acid (RA) in a surgical rabbit model of congenital diaphragmatic hernia showed a beneficial effect on lung maturation. We evaluated the potential of RA delivery into the trachea and studied the combined effects of TO and RA on normal lung development. Experiments were performed on normal rabbit fetuses. Liposomes and capric triglyceride (Miglyol ® ), alone and with RA, were administered in the trachea just before TO (d26). Lung morphology and surfactant production were studied at term (d30). Tracheal occlusion increased lung weight and enhanced alveolar development but increased apoptotic activity and decreased surfactant expression. Tracheal injection of RA improved surfactant production to levels of normal controls. We established the potential of liposome and Miglyol as RA vehicle for delivering this bioactive molecule in the fetal airways. Tracheal RA injection seems to oppose the effects of TO in fetuses with normal lungs. © 2017 John Wiley & Sons, Ltd. © 2017 John Wiley & Sons, Ltd.

  5. Viscoelastic Properties of Human Tracheal Tissues.

    Science.gov (United States)

    Safshekan, Farzaneh; Tafazzoli-Shadpour, Mohammad; Abdouss, Majid; Shadmehr, Mohammad B

    2017-01-01

    The physiological performance of trachea is highly dependent on its mechanical behavior, and therefore, the mechanical properties of its components. Mechanical characterization of trachea is key to succeed in new treatments such as tissue engineering, which requires the utilization of scaffolds which are mechanically compatible with the native human trachea. In this study, after isolating human trachea samples from brain-dead cases and proper storage, we assessed the viscoelastic properties of tracheal cartilage, smooth muscle, and connective tissue based on stress relaxation tests (at 5% and 10% strains for cartilage and 20%, 30%, and 40% for smooth muscle and connective tissue). After investigation of viscoelastic linearity, constitutive models including Prony series for linear viscoelasticity and quasi-linear viscoelastic, modified superposition, and Schapery models for nonlinear viscoelasticity were fitted to the experimental data to find the best model for each tissue. We also investigated the effect of age on the viscoelastic behavior of tracheal tissues. Based on the results, all three tissues exhibited a (nonsignificant) decrease in relaxation rate with increasing the strain, indicating viscoelastic nonlinearity which was most evident for cartilage and with the least effect for connective tissue. The three-term Prony model was selected for describing the linear viscoelasticity. Among different models, the modified superposition model was best able to capture the relaxation behavior of the three tracheal components. We observed a general (but not significant) stiffening of tracheal cartilage and connective tissue with aging. No change in the stress relaxation percentage with aging was observed. The results of this study may be useful in the design and fabrication of tracheal tissue engineering scaffolds.

  6. Tracheal morphology and collapse in COPD: Correlation with CT indices and pulmonary function test

    International Nuclear Information System (INIS)

    Lee, Hyun Joo; Seo, Joon Beom; Chae, Eun Jin; Kim, Namkug; Lee, Choong Wook; Oh, Yeon-Mok; Lee, Sang Do

    2011-01-01

    Objectives: To assess the tracheal morphologic changes using CT in COPD (chronic obstructive lung disease) patients and to assess correlation between them and PFT (pulmonary function test) and CT parameters. Materials and methods: Ninety-two healthy individuals and 115 patients with COPD who underwent volumetric inspiration/expiration CT scanning were included. The Lsag, Lcor, and the tLA were measured. The TI was defined as the ratio of Lcor/Lsag. The tracheal morphologic changes (tLA, TI, and collapsibility) were compared in healthy individuals and COPD. In COPD patients, correlation of the tracheal morphologic change with PFT and CT parameters was assessed. Results: The TIs in the COPD patients were significantly lower than those in the control group (0.80 ± 0.15 vs. 0.88 ± 0.11, Mean ± SD) (p 1 (r = 0.29, p = 1 /FVC (r = 0.26, p < 0.01), and the GOLD stage (r = −0.26, p < 0.01). TI showed significant correlation with EI on both inspiration and expiration CT (r = −0.19, p = 0.04 and r = −0.23, p = 0.02), MLD on expiration CT (r = 0.27, p < 0.01), CT–ATI (r = 0.34, p < 0.01), and with LV on expiration CT (r = −0.25, p < 0.01). Conclusion: Among the tracheal morphologic changes, the most significant change in COPD patients compared with that in the control group, was the TI. In COPD patients, the tracheal morphologic change showed clinically significant correlation with severity of emphysema and CT indices.

  7. Effects of acute respiratory virus infection upon tracheal mucous transport

    International Nuclear Information System (INIS)

    Gerrard, C.S.; Levandowski, R.A.; Gerrity, T.R.; Yeates, D.B.; Klein, E.

    1985-01-01

    Tracheal mucous velocity was measured in 13 healthy non-smokers using an aerosol labelled with /sup 99m/Tc and a multidetector probe during respiratory virus infections. The movement of boluses of tracheal mucous were either absent or reduced in number in five subjects with myxovirus infection (four influenza and one respiratory syncytial virus) within 48 hr of the onset of symptoms and in four subjects 1 wk later. One subject with influenza still had reduced bolus formation 12-16 wk after infection. Frequent coughing was a feature of those subjects with absent tracheal boluses. In contrast, four subjects with rhinovirus infection had normal tracheal mucous velocity at 48 hr after the onset of symptoms (4.1 +/- 1.3 mm/min). Tracheal mucous velocity was also normal (4.6 +/- 1.1 mm/min) in four subjects in whom no specific viral agent could be defined but had typical symptomatology of respiratory viral infection. During health tracheal mucous velocity was normal (4.8 +/- 1.6 mm/min) in the eleven subjects who had measurements made. Disturbances in tracheal mucous transport during virus infection appear to depend upon the type of virus and are most severe in influenza A and respiratory syncytial virus infection

  8. Neutron generator tube ion source control

    International Nuclear Information System (INIS)

    Bridges, J.R.

    1982-01-01

    A system is claimed for controlling the output of a neutron generator tube of the deuterium-tritium accelerator type and having an ion source to produce sharply defined pulses of neutrons for well logging use. It comprises: means for inputting a relatively low voltage input control pulse having a leading edge and a trailing edge; means, responsive to the input control pulse, for producing a relatively high voltage ion source voltage pulse after receipt of the input pulse; and means, responsive to the input control pulse, for quenching, after receipt of the input pulse, the ion source control pulse, thereby providing a sharply time defined neutron output from the generator tube

  9. Static end-expiratory and dynamic forced expiratory tracheal collapse in COPD

    International Nuclear Information System (INIS)

    O'Donnell, C.R.; Bankier, A.A.; O'Donnell, D.H.; Loring, S.H.; Boiselle, P.M.

    2014-01-01

    Aim: To determine the range of tracheal collapse at end-expiration among chronic obstructive pulmonary disease (COPD) patients and to compare the extent of tracheal collapse between static end-expiratory and dynamic forced-expiratory multidetector-row computed tomography (MDCT). Materials and methods: After institutional review board approval and obtaining informed consent, 67 patients meeting the National Heart, Lung, and Blood Institute (NHLBI)/World Health Organization (WHO) Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria for COPD were sequentially imaged using a 64-detector-row CT machine at end-inspiration, during forced expiration, and at end-expiration. Standardized respiratory coaching and spirometric monitoring were employed. Mean percentage tracheal collapse at end-expiration and forced expiration were compared using correlation analysis, and the power of end-expiratory cross-sectional area to predict excessive forced-expiratory tracheal collapse was computed following construction of receiver operating characteristic (ROC) curves. Results: Mean percentage expiratory collapse among COPD patients was 17 ± 18% at end-expiration compared to 62 ± 16% during forced expiration. Over the observed range of end-expiratory tracheal collapse (approximately 10–50%), the positive predictive value of end-expiratory collapse to predict excessive (≥80%) forced expiratory tracheal collapse was <0.3. Conclusion: COPD patients demonstrate a wide range of end-expiratory tracheal collapse. The magnitude of static end-expiratory tracheal collapse does not predict excessive dynamic expiratory tracheal collapse

  10. Effects of Lavender Inhalant on the Pain during Endotracheal Suctioning in Intensive Care Unit Patients

    Directory of Open Access Journals (Sweden)

    M. Taheri Rezgh Abadi

    2017-09-01

    Full Text Available Aims: Patients undergoing artificial ventilation require tracheal tube suction because of inability to clear their effective airways, which is usually a painful process for the patients. The aim of this study was to investigate the effect of spike lavender’s inhalant on pain during tracheal tube suctioning in ICU intubated patients. Materials & Methods: In this double-blinded randomized clinical trial, 60 intubated patients hospitalized in ICU of Shahid Modarres Hospital of Kashmar City, Iran, in 2017 were selected by available and simple sampling method, and were randomly divided into 2 control and case groups (each 30 individuals. Before the standard suctioning process, the test group patients received inhalant of 2% spike lavender for 5 minutes and the control group received inhalant of distilled water. The level of pain was recorded before and during tracheal tube suctioning. Data were analyzed by SPSS 16 software using independent T, paired T, Fisher and Mann-Whitney U tests. Findings: There was no significant difference in pain score before tracheal tube suction between 2 groups (p>0.05. However, there were significant differences between the level of pain during tracheal tube suctioning and the pain was increased in both groups, but this increase was significantly higher in the control group (p<0.001. Conclusion: Spike lavender’s inhalant is effective on pain reduction during suctioning process of ICU intubated patients.

  11. Tracheal stenosis after treatment with metallic stent: a situation worse than the initial problem

    International Nuclear Information System (INIS)

    Barreto, Jaime; Mejia, Bibiana; Nino, Federico; Garavito, Carlos

    2008-01-01

    Stens are a tubular device for use in trachea, carina or main bronchus to provide a support and maintain the permeability of these structures. There are two groups: Metallic and Silicone stent. Either metallic and silicone stents has a special properties. Metallic stent are very attractive option due to relative easy in their placement. The accumulated experience in this therapy has allowed to recognize several complications to take into consideration mainly in patients with tracheal benign stenosis. FDA has recommended don't use metallic stents, covered and not covered in benign diseases. We report a case of a tracheal stenosis secondary to prolonged ortho tracheal intubation that required extensive interventions to control symptoms of central airway obstruction, between April and July of 2005.

  12. Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation.

    LENUS (Irish Health Repository)

    Maharaj, C H

    2008-02-01

    The Airtraq, a novel single use indirect laryngoscope, has demonstrated promise in the normal and simulated difficult airway. We compared the ease of intubation using the Airtraq with the Macintosh laryngoscope, in patients at increased risk for difficult tracheal intubation, in a randomised, controlled clinical trial. Forty consenting patients presenting for surgery requiring tracheal intubation, who were deemed to possess at least three characteristics indicating an increased risk for difficulty in tracheal intubation, were randomly assigned to undergo tracheal intubation using a Macintosh (n = 20) or Airtraq (n = 20) laryngoscope. All patients were intubated by one of three anaesthetists experienced in the use of both laryngoscopes. Four patients were not successfully intubated with the Macintosh laryngoscope, but were intubated successfully with the Airtraq. The Airtraq reduced the duration of intubation attempts (mean (SD); 13.4 (6.3) vs 47.7 (8.5) s), the need for additional manoeuvres, and the intubation difficulty score (0.4 (0.8) vs 7.7 (3.0)). Tracheal intubation with the Airtraq also reduced the degree of haemodynamic stimulation and minor trauma compared to the Macintosh laryngoscope.

  13. Surgery for postintubation tracheal and tracheosubglottic stenotic lesions

    International Nuclear Information System (INIS)

    Ashour, M.; Al-Kattan, K.; Rafay, M.A.; El-Bakry, A.K.; El-Dawlatly, A.; Naguib, M.; Seraj, M.; Joharjy, I.; Al-Serhani, A.

    1996-01-01

    Postintubation tracheal stenosis is a recognized problem. Although its incidence has recently decreased, it is still a difficult complication to treat. We have reviewed our experience with 10 patients with tracheal stenosis over the last five years between 1990 and 1995. There were seven male and three female patients with an average age of 14.2+-4 years (range 6 to 48 years). Resection and reconstruction with primary anastomosis was performed in seven patients, while conservative treatment with dilation was performed in two patients. One patient refused surgery. Operations performed included resection of tracheocricoid segment with tracheothyroid anastomosis (N=3) and tracheal resection with end-to-end anastomosis (N=4). The resected airway ranged from 3 cm to 6 cm. In view of the intense inflammatory and fibrotic process in and around stenotic segment, the practice of tracheostomy for the relief of postintubation acute tracheal obstruction should not be taken lightly, as it adds not only to the severity of the inflammatory process, but also increases the length of the tracheal segment to be resected. Postoperatively, all patients were extubated; this was accomplished by the end of surgery in six patients, while the seventh patient was extubated three weeks later. There was no mortality in this series. When normal functional activity and airway patency were taken as two parameters to judge the outcome of the surgery, results were good in six (86%) patients and satisfactory in one. These results support the validity of the one-stage reconstruction approach as one alternative for the treatment of postintubation tracheal and tracheosubglottic stenotic lesions. (author)

  14. Airway Management in a Patient With Tracheal Disruption due to Penetrating Neck Trauma With Hollow Point Ammunition: A Case Report.

    Science.gov (United States)

    Johnson, Angela M; Hill, James L; Zagorski, Dave J; McClain, Joseph M; Maronian, Nicole C

    2018-05-01

    Rapid sequence induction and intubation was performed for a patient in respiratory distress after a gunshot wound to the neck. Resistance was noted distal to vocal cords. With a bronchoscope unavailable, the endotracheal tube was advanced with a corkscrew maneuver. Subcutaneous emphysema had developed. The endotracheal tube was advanced into the right mainstem with adequate ventilation. Imaging illustrated tracheoesophageal injury. The patient was emergently explored. An intraluminal bullet was removed, lateral wall tracheal defect was repaired, and a tracheostomy was placed. The intubating provider should secure the airway by the method they are most comfortable, have high suspicion of airway injury, and prepare to manage airway disruption.

  15. Management of Tracheal Deformity During Intubation: A Case Report

    Directory of Open Access Journals (Sweden)

    Sheng-Hua Wu

    2007-06-01

    Full Text Available Failure or difficulty in intubating the trachea can be either due to inability to visualize the glottis or some pathology at the level of or below the cords. This report describes a case of difficult intubation suspected of being related to neck scarring from previous surgery. Computed tomography (CT was used to evaluate the patient's airway and revealed upper tracheal angulation. We describe a method to secure the airway in this patient with a two-person technique by rotating an oral endotracheal tube 180° counterclockwise to adjust to the curvature of the trachea. Problems with intubation should be anticipated in patients with scarring of the neck, and equipment for aiding intubation should be on hand. Furthermore, we found that CT contributed to the assessment of the difficulty of intubation in this kind of patient.

  16. Control rod guide tube assemblies

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1979-01-01

    A nuclear fuel assembly including sleeves telescoped over end portions of control rod guide tubes which bear against internal shoulders of the sleeves. Upper ends of the sleeves protrude beyond a control rod guide tube spider and are locked in place by means of a resilient cellular lattice or lock that is seated in mating grooves in the outer surfaces of the sleeves. A grapple is provided for disengaging the entire lock structure spider and associated washers, springs and a grill from the end of the fuel assembly in order to enable these components to be removed and subsequently replaced on the fuel assembly after inspection and repair. (UK)

  17. Evaluation of Tracheal and Main Bronchial Diverticula Using Thin-Section MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Jou, Sung Shick; Kim, Young Tong; Bae, Won Kyung; Kim, Il Yung; Kim, Hyung Hwan; Han, Jong Kyu [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of)

    2010-02-15

    To evaluate the characteristics of tracheal and main bronchial diverticula in relation with emphysema. A total of 967 CT images were reconstructed with 1.25 mm axial images over 2 months. The incidence, size, number, and location of the tracheal and main bronchial diverticula were analyzed using 3D medical software (Seoul, Korea). The incidence of emphysema and the relationship between emphysema and the size of the diverticula were analyzed. In total, 50 patients (5.1%) showed tracheal diverticula in the right posterolateral wall. In addition, 51 patients (5.2%) showed 89 (9.4%) main bronchial diverticula in the inferior wall, while 68 (72%) showed diverticula in the left posterolateral wall. Tracheal diverticula (6.4 {+-} 5.0 mm, 1.0 {+-} 0.2) were larger and fewer than the main bronchial diverticula (2.1 {+-} 2.0 mm, 1.8 {+-} 1.6) (p<0.05). Moreover, tracheal diverticula (10.3 {+-} 7.4 mm) with emphysema in 13 patients (26%), were larger than those without emphysema (5.1 {+-} 3.0 mm) (p<0.05). On thin-section MDCT, the rates of incidence for tracheal and main bronchial diverticula are about 5%, respectively. Tracheal diverticula in the right posterolateral wall are smaller and fewer than the main bronchial diverticula, which are located primarily in the inferior wall of the left bronchus. Tracheal diverticula with emphysema are larger than those without emphysema.

  18. Tracheoesophageal Fistula due to a Damaged Tracheal Stent

    Directory of Open Access Journals (Sweden)

    Masahiro Kimura

    2014-01-01

    Full Text Available We describe the management of a tracheoesophageal fistula due to a damaged tracheal stent, which was first inserted to treat tracheal stenosis. A 29-year-old woman with a history of treated epilepsy had a seizure and suffered from smoke inhalation during a fire. Breathing difficulties appeared and gradually worsened; consultation was obtained two years afterward. After undergoing a thorough examination, the patient was diagnosed with tracheal strangulation. A noncovered, metallic stent was inserted. When the patient was 37 years old, she was admitted to our hospital for the treatment of a tracheoesophageal fistula. We diagnosed it as a tracheoesophageal fistula due to the collapse of the damaged tracheal stent toward the esophageal side, and we decided to perform a mediastinal tracheostomy. Granulation may be formed in the circumference of a stent that has been present for a prolonged period, and removal of the stent may become difficult. This case suggests that insertion of a noncovered, metallic stent is contraindicated for a benign disease.

  19. New Approaches to Airway Management in Tracheal Resections-A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Schieren, Mark; Böhmer, Andreas; Dusse, Fabian; Koryllos, Aris; Wappler, Frank; Defosse, Jerome

    2017-08-01

    Although endotracheal intubation, surgical crossfield intubation, and jet ventilation are standard techniques for airway management in tracheal resections, there are also reports of new approaches, ranging from regional anesthesia to extracorporeal support. The objective was to outline the entire spectrum of new airway techniques. The literature databases PubMed/Medline and the Cochrane Library were searched systematically for prospective and retrospective trials as well as case reports on tracheal resections. No restrictions applied to hospital types or settings. Adult patients undergoing surgical resections of noncongenital tracheal stenoses with end-to-end anastomoses. Airway management techniques were divided into conventional and new approaches and analyzed regarding their potential risks and benefits. A total of 59 publications (n = 797 patients) were included. The majority of publications (71.2%) describe conventional airway techniques. Endotracheal tube placement after induction of general anesthesia and surgical crossfield intubation after incision of the trachea were used most frequently without major complications. A total of 7 new approaches were identified, including 4 different regional anesthetic techniques (25 cases), supraglottic airways (4 cases), and new forms of extracorporeal support (25 cases). Overall failure rates of new techniques were low (1.8%). Details on patient selection and procedural specifics are provided. New approaches have several theoretical benefits, yet further research is required to establish criteria for patient selection and evaluate procedural safety. Given the low level of evidence, it currently is impossible to compare methods of airway management regarding outcome-related risks and benefits. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. What's in a name? Expiratory tracheal narrowing in adults explained

    International Nuclear Information System (INIS)

    Leong, P.; Bardin, P.G.; Lau, K.K.

    2013-01-01

    Tracheomalacia, tracheobronchomalacia, and excessive dynamic airway collapse are all terms used to describe tracheal narrowing in expiration. The first two describe luminal reduction from cartilage softening and the latter refers to luminal reduction from exaggerated posterior membrane movement. Expiratory tracheal narrowing is a frequent occurrence that can cause symptoms of airway obstruction, such as dyspnoea, wheeze, and exercise intolerance. The accurate diagnosis and quantification of expiratory tracheal narrowing has important aetiological, therapeutic, and prognostic implications. The reference standard for diagnosis has traditionally been bronchoscopy; however, this method has significant limitations. Expiratory tracheal disorders are readily detected by four-dimensional dynamic volume multidetector computed tomography (4D-CT), an emerging, non-invasive method that will potentially enable detection and quantification of these conditions. This review discusses the morphological forms of expiratory tracheal narrowing and demonstrates the utility of 4D-CT in the diagnosis, quantification, and treatment of these important conditions

  1. A Comfortable Solution To Tracheal Anastomosis Protection: Tracheal Retention Sutures.

    Science.gov (United States)

    Karapolat, Sami; Turkyilmaz, Atila; Seyis, Kubra Nur; Tekinbas, Celal

    2018-04-01

    Fixation of the chin to the anterior chest wall is the most commonly used method of reducing anastomotic tension following a segmental resection of the trachea and reconstruction with primary anastomosis. However, the sutures required for this method may lead to various organic and psychological problems. In five patients who underwent tracheal resection and primary anastomosis, retention sutures were placed on the proximal and distal-lateral edges of the anastomotic line rather than placing a Guardian chin stitch. All patients were mobilised in the early postoperative period and were able to perform their routine daily activities without restrictions. During their average 14.4 months of follow-up, no complications were found in their anastomotic lines during their clinical, radiological, and bronchoscopic assessments. The placement of tracheal retention sutures proved an inexpensive and reliable method to reduce anastomotic tension without additional surgical burden, and was effective in terms of patient comfort. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  2. Tracheal anastomosis with the diode laser and fibrin tissue adhesive: an in vitro and in vivo investigation.

    Science.gov (United States)

    Gleich, L L; Wang, Z; Pankratov, M M; Aretz, H T; Shapshay, S M

    1995-05-01

    Absorbable sutures have been advocated for tracheal anastomosis to reduce fibrosis and foreign body reaction leading to recurrent stenosis. Fibrin tissue adhesive (FTA) and diode laser welding with indocyanine green-dyed fibrinogen were evaluated in tracheal anastomosis to reduce the number of sutures and to improve healing. In vitro studies demonstrated strong anastomoses with a combination of laser welding and FTA with minimal tissue damage. In a controlled in vivo study, circumferential resections of canine tracheas were repaired with laser welding and FTA augmented with a few stay sutures. These anastomoses had less fibrosis and tissue damage than anastomoses in control animals repaired with sutures alone. This study supports investigation of laser welding and FTA in human beings for tracheal anastomosis and other procedures in which suturing may be difficult.

  3. Fractured tracheostomy tube – A case report of a 3-year old Ghanaian child

    Directory of Open Access Journals (Sweden)

    Akwasi Antwi-Kusi

    2012-09-01

    Discussion: Fracture of a tracheostomy tube is a rare complication, which should be considered as part of the differential diagnosis in a ventilated patient with a tracheostomy. Wound exploration through the tracheal stoma is an alternative technique that can be adopted in a restricted resource setting.

  4. Use of the peritracheal fold in the dog tracheal transplantation model.

    Science.gov (United States)

    Gannon, P J; Costantino, P D; Lueg, E A; Chaplin, J M; Brandwein, M S; Passalaqua, P J; Fliegelman, L J; Laitman, J T; Marquez, S; Urken, M L

    1999-09-01

    To investigate the technical aspects of the canine model of human tracheal transplantation for potential application to reconstruction of extremely long tracheal defects (> 10 cm). In phase 1, long tracheal segments were skeletonized and pedicled with the thyroid glands, cranial thyroid arteries and veins, and internal jugular vein branches. The segments were elevated completely, attached to the vascular pedicle only, and replaced with primary tracheal anastomoses. In phase 2, long segments were elevated along with a diffuse soft tissue "blanket" that envelops the trachea and thyroid glands. Because this study was designed to primarily address, in situ, tracheal perfusion territories of a cranially located vascular pedicle, microvascular anastomoses were not conducted. Two small-bodied beagles (10-15 kg) and 5 large-bodied mixed-breed dogs (20-30 kg) were humanely killed 2 to 41 days after surgery, and anatomic and histological analyses were conducted. Unlike that of humans, the thyroid gland complex of dogs is not intimately associated with the trachea but is conjoined with a peritracheal soft tissue "fold." Within this fold, blood is transmitted to the trachea via a diffuse, segmental vascular plexus. In phase 1, pronounced tracheal necrosis occurred within 2 to 5 days. In phase 2, extremely long tracheal segments (10-12 cm), based only on a cranially located pedicle, were still viable at 2 to 6 weeks. Preservation of the "peritracheal fold" in the dog model of tracheal transplantation is critical to the onset and maintenance of vascular perfusion in a long tracheal segment. Furthermore, the use of large-bodied dogs is necessary to provide for a usable venous efflux component.

  5. Tracheal schwannoma: Completely resected with therapeutic bronchoscopic techniques

    Directory of Open Access Journals (Sweden)

    Barney Thomas Jesudason Isaac

    2015-01-01

    Full Text Available Tracheal schwannomas are rare benign tumors of the trachea. There are only a few reported cases in the literature. Surgeons have generally resected these tumors, whereas bronchoscopists have attempted to remove them bronchoscopically. We report a case of tracheal schwannoma which was completely resected using bronchoscopic techniques.

  6. Treatment of a case of tracheal stenosis in a dog with tracheal resection and anastomosis

    International Nuclear Information System (INIS)

    Mutlu, Z.; Acar, S.E.; Perk, C.

    2003-01-01

    A case of tracheal stenosis in the cervical portion of the trachea was encountered in a 5.5-month-old St. Bernard-Rottweiler cross dog. Breathing difficulty was seen in the clinical examination and presence of an obvious narrowing between the 3rd-5th cervical tracheal rings was determined in the radiological examination. Under general anesthesia the portion with stenosis was resected and the healthy trachea ends were anastomosed using the split cartilage technique. In the postoperative period the breathing difficulty disappeared and there was no development of a new stenosis in the anastomosis region. In the late period check-up the patient was seen to lead a healthy life

  7. Tracheostomy Tube Ignition During Microlaryngeal Surgery Using Diode Laser: A Case Report

    Directory of Open Access Journals (Sweden)

    Hsun-Mo Wang

    2006-04-01

    Full Text Available Ignition of the tracheal tube during laser microlaryngeal surgery under general anesthesia is an uncommon complication with potentially serious consequences. We present here a case of a patient with glottic stenosis following endotracheal intubation, who experienced this potentially catastrophic combustion during endoscopic arytenoidectomy, using a diode laser under general anesthesia via 60% FiO2, with an airway fire occurring at the tracheostomy tube and causing tubal damage and obstruction. The anesthetic connecting tube was immediately disconnected and the tracheostomy tube replaced. No adverse consequences to this patient's upper airway were noted during follow-up visits. Higher oxygen concentrations, the presence of combustibles, and the narrowness of the surgical field during endolaryngeal diode laser surgery are risk factors for airway fires.

  8. Two-piece cryopreserved tracheal allotransplantation: an experimental study.

    Science.gov (United States)

    Iyikesici, Tuncel; Tuncozgur, Bulent; Sanli, Maruf; Isik, Ahmet Feridun; Meteroglu, Fatih; Elbeyli, Levent

    2009-10-01

    For successful reconstruction with tracheal allotransplants following long tracheal resections, problems related to the preservation and vascularisation of the tracheal graft have to be solved. In this study, instead of using a long-segment single-piece graft, we used a graft that has been split into two. The aim was to use this graft after cryopreservation in order to ease neo-vascularisation and to maintain tracheal integrity by transplanting it to two separate regions of the dog cervical trachea. This experimental study was conducted in animal laboratories of the medical school on 11 half-blood dogs. The trachea obtained from the first dog was 8 cm in length; it was split into two pieces of 4 cm each and stored in the preservation solution at -80 degrees C for 4 weeks. Following this, the dog was sacrificed. Two 2 cm portions of cervical trachea were excised from the second dog. These parts were then reconstructed with two tracheal grafts of the same length as the cryopreserved ones. Ten dogs that were grouped into five groups of two dogs each underwent the same procedure. The subjects had a bronchoscopic evaluation on the third postoperative week. Anastomosis regions of the test tracheas were resected to be examined histopathologically. Seven subjects were found to have third-degree obstructions during bronchoscopy; two had close to fourth-degree obstructions. In the histopathological examination, contrary to the findings of the bronchoscopies, 75% of the anastomoses had intact epithelium. The cartilage was seen to have well-preserved structural characteristics in all the anastomoses. Twelve anastomoses had moderate, seven mild and one had severe inflammation. All anastomoses had either good or very good level of vascularisation. The integrity of the tracheal epithelium can be maintained with cryopreservation and split anastomosis technique. The cartilage preserves its structural characteristics despite losing its viability, thereby offering an advantage to

  9. Surgical treatment of benign tracheo-oesophageal fistulas with tracheal resection and oesophageal primary closure: is the muscle flap really necessary?

    Science.gov (United States)

    Camargo, José Jesus; Machuca, Tiago Noguchi; Camargo, Spencer Marcantônio; Lobato, Vivalde F; Medina, Carlos Remolina

    2010-03-01

    Nowadays, despite the advances of the low-pressure high-volume cuffs, post-intubation tracheo-oesophageal fistula (TEF) still poses a major challenge to thoracic surgeons. The original technique includes interposition of muscle flaps between suture lines to avoid recurrence. It is not clear if this manoeuvre is indispensable and, in fact, we and others have faced problems with it. Our aim is to present our experience with TEF management in a consecutive group with no muscle interposition. From June 1992 to November 2007, we evaluated 14 patients presenting with TEF, with a mean age of 44 years (from 18 to 79 years). Thirteen patients had a prolonged intubation history. The remaining case was a 40-year-old male with congenital TEF. Three patients had been previously submitted to failed repairs in other institutions. Ten patients had associated tracheal stenosis, which was subglottic in three of them. Regarding surgical technique, in all cases, we performed a single-staged procedure, which consisted of tracheal resection and anastomosis with double-layer oesophageal closure. In none of our cases was a muscle flap interposed between suture lines. All operations were performed through a cervical incision; however, in one case, an extension with partial sternotomy was required. There was no operative mortality. Thirteen patients were extubated in the first 24h after the procedure, while one patient required 48 h of mechanical ventilation. Four complications were recorded: one each of pneumonia and left vocal cord paralysis and two small tracheal dehiscences managed with a T-tube and a tracheostomy tube. After discharge, three patients returned to their native cities and were lost to follow-up. The remaining 11 patients have been followed up by a mean of 32 months (from three to 108 months), with 10 presenting excellent and one good anatomic and functional results. The single-staged repair with tracheal resection and anastomosis with oesophageal closure provides good

  10. Electroacoustic control of Rijke tube instability

    Science.gov (United States)

    Zhang, Yumin; Huang, Lixi

    2017-11-01

    Unsteady heat release coupled with pressure fluctuation triggers the thermoacoustic instability which may damage a combustion chamber severely. This study demonstrates an electroacoustic control approach of suppressing the thermoacoustic instability in a Rijke tube by altering the wall boundary condition. An electrically shunted loudspeaker driver device is connected as a side-branch to the main tube via a small aperture. Tests in an impedance tube show that this device has sound absorption coefficient up to 40% under normal incidence from 100 Hz to 400 Hz, namely over two octaves. Experimental result demonstrates that such a broadband acoustic performance can effectively eliminate the Rijke-tube instability from 94 Hz to 378 Hz (when the tube length varies from 1.8 m to 0.9 m, the first mode frequency for the former is 94 Hz and the second mode frequency for the latter is 378 Hz). Theoretical investigation reveals that the devices act as a damper draining out sound energy through a tiny hole to eliminate the instability. Finally, it is also estimated based on the experimental data that small amount of sound energy is actually absorbed when the system undergoes a transition from the unstable to stable state if the contrpaol is activated. When the system is actually stabilized, no sound is radiated so no sound energy needs to be absorbed by the control device.

  11. Open Tracheostomy after Aborted Percutaneous Approach due to Tracheoscopy Revealing Occult Tracheal Wall Ulcer

    Directory of Open Access Journals (Sweden)

    John Schweiger

    2013-01-01

    Full Text Available Tracheostomy is a common procedure for intensive care patients requiring prolonged mechanical ventilation. In this case report, we describe a 78-year-old female patient admitted for an aneurysm of the cerebral anterior communicating artery. Following immediate endovascular coiling, she remained ventilated and was transferred to the neurological intensive care unit. On postoperative day ten, a percutaneous tracheostomy (PCT was requested; however, a large ulcer or possible tracheoesophageal fistula was identified on the posterior tracheal wall following bronchoscopic assessment of the trachea. Therefore, the requested PCT procedure was aborted. An open tracheostomy in the operating room was completed; however, due to the position and depth of the ulcer, a reinforced endotracheal tube (ETT was placed via the tracheostomy. Four days later, the reinforced ETT was replaced with a Shiley distal extended tracheostomy tube to bypass the ulceration. Careful inspection and evaluation of the tracheostomy site before PCT prevented a potentially life-threatening issue in our patient.

  12. Vardenafil inhibiting parasympathetic function of tracheal smooth muscle.

    Science.gov (United States)

    Lee, Fei-Peng; Chao, Pin-Zhir; Wang, Hsing-Won

    2018-07-01

    Levitra, a phosphodiesterase-5 (PDE5) inhibitor, is the trade name of vardenafil. Nowadays, it is applied to treatment of erectile dysfunction. PDE5 inhibitors are employed to induce dilatation of the vascular smooth muscle. The effect of Levitra on impotency is well known; however, its effect on the tracheal smooth muscle has rarely been explored. When administered for sexual symptoms via oral intake or inhalation, Levitra might affect the trachea. This study assessed the effects of Levitra on isolated rat tracheal smooth muscle by examining its effect on resting tension of tracheal smooth muscle, contraction caused by 10 -6  M methacholine as a parasympathetic mimetic, and electrically induced tracheal smooth muscle contractions. The results showed that adding methacholine to the incubation medium caused the trachea to contract in a dose-dependent manner. Addition of Levitra at doses of 10 -5  M or above elicited a significant relaxation response to 10 -6  M methacholine-induced contraction. Levitra could inhibit electrical field stimulation-induced spike contraction. It alone had minimal effect on the basal tension of the trachea as the concentration increased. High concentrations of Levitra could inhibit parasympathetic function of the trachea. Levitra when administered via oral intake might reduce asthma attacks in impotent patients because it might inhibit parasympathetic function and reduce methacholine-induced contraction of the tracheal smooth muscle. Copyright © 2018. Published by Elsevier Taiwan LLC.

  13. Successful Treatment of Anterior Tracheal Necrosis after Total Thyroidectomy Using Vacuum-Assisted Closure Therapy

    Directory of Open Access Journals (Sweden)

    Grégory Philippe

    2012-01-01

    Full Text Available Total thyroidectomy involving the adjacent structures of the trachea can cause tracheal damage such as early tracheal necrosis. The authors describe the first case of anterior tracheal necrosis following total thyroidectomy treated using vacuum-assisted closure device. After two weeks of VAC  therapy, there was no evidence of ongoing infection and the trachea was partially closed around a tracheotomy cannula, removed after 3 months. The use of a VAC  therapy to reduce and close the tracheal rent and to create a rapid granulation tissue over tracheal structure appeared as a good opportunity after anterior tracheal necrosis.

  14. The use of scaning electron microscopy in postvaccinal evaluation of tracheal epithelium of Coturnix coturnix japonica

    Directory of Open Access Journals (Sweden)

    Santin Elizabeth

    2003-01-01

    Full Text Available This study aimed at evaluating the use of scanning electron microscopy in the study of the post-vaccinal respiratory reaction of the tracheal epithelium of quails (Coturnix coturnix japonica immunized against Newcastle disease. A number of 36 quails were distributed into four groups: T1 fraction three-quarters control birds (non-vaccinated; T2 fraction three-quarters birds vaccinated with Ulster 2C strain; t3 fraction three-quarters birds vaccinated with B1 strain; t4 fraction three-quarters birds vaccinated with LaSota strain. Regardless the experimental group, birds did not show detectable clinical signs of post-vaccinal respiratory reaction. However, the analysis of tracheal fragments by scanning electron microscopy showed that birds vaccinated with B1 and LaSota strains developed epithelial sloughing of the trachea, whereas those vaccinated Ulster 2C strain did not develop this change, demonstrating intact tracheal epithelium, similar to the control group.

  15. Randomized Pilot Trial of Two Modified Endotracheal Tubes To Prevent Ventilator-associated Pneumonia.

    Science.gov (United States)

    Deem, Steven; Yanez, David; Sissons-Ross, Laura; Broeckel, Jo Ann Elrod; Daniel, Stephen; Treggiari, Miriam

    2016-01-01

    Ventilator-associated pneumonia (VAP) is a prevalent and costly nosocomial infection related to instrumentation of the airway with an endotracheal tube (ETT), enabling microaspiration of contaminated secretions. Modification of the ETT design to reduce microaspiration and/or biofilm formation may play an important role in VAP prevention. However, there is insufficient evidence to provide strong recommendations regarding the use of modified ETT and unaddressed safety concerns. We performed a pilot randomized controlled trial comparing two modified ETTs designed specifically to prevent VAP, with the standard ETT, to test the feasibility of and inform planning for a large, pivotal, randomized trial. This study was conducted with institutional review board approval under exception from informed consent. We randomized in a blinded fashion patients undergoing emergency endotracheal intubation both out of and in hospital to receive one of three different ETT types: (1) a polyurethane-cuffed tube (PUC-ETT), (2) a polyurethane-cuffed tube equipped with a port for continuous aspiration of subglottic secretions (PUC-CASS-ETT), or a (3) standard polyvinylchloride-cuffed tube (PVC-ETT). In addition to investigating feasibility and safety, the study coprimary end points were tracheal bacterial colonization reaching a cfu count >10(6) cfu per milliliter and the incidence of invasively diagnosed VAP. A total of 102 subjects were randomized and met the eligibility criteria. Randomization procedures performed well and integrity of blinding at randomization was maintained. The majority of intubations occurred in the hospital setting (n = 77), and the remainder occurred out of hospital (n = 25). Compared with the PVC-ETT, there were no significant differences in tracheal colonization for PUC-ETT (odds ratio [OR], 0.98; 95% confidence interval [CI], 0.31-3.09) or for PUC-CASS-ETT (OR, 1.26; 95% CI, 0.42-3.76). There were no differences in the risk of invasively diagnosed VAP

  16. [Circular tracheal resection for cicatrical stenosis and functioning tracheostomy].

    Science.gov (United States)

    Parshin, V D; Titov, V A; Parshin, V V; Parshin, A V; Berikkhanov, Z; Amangeldiev, D M

    To analyze the results of tracheal resection for cicatricial stenosis depending on the presence of tracheostomy. 1128 patients with tracheal cicatricial stenosis were treated for the period 1963-2015. The first group consisted of 297 patients for the period 1963-2000, the second group - 831 patients for the period 2001-2015. Most of them 684 (60.6%) were young and able-bodied (age from 21 to 50 years). In the first group 139 (46.8%) out of 297 patients had functioning tracheostomy. For the period 2001-2015 tracheostomy was made in 430 (51.7%) out of 831 patients with cicatricial stenosis. Time of cannulation varied from a few weeks to 21 years. Re-tracheostomy within various terms after decanulation was performed in 68 (15.8%) patients. Tracheal resection with anastomosis was performed in 59 and 330 in both groups respectively. At present time these operations are performed more often in view of their standard fashion in everyday practice. In the second group tracheal resection followed by anastomosis was observed in 110 (25.6%) out of 430 patients with tracheostomy that is 4.4 times more often than in previous years. In total 2 patients died after 330 circular tracheal resections within 2001-2015 including one patient with and one patient without tracheostomy. Mortality was 0.6%. Moreover, this value was slightly higher in patients operated with a functioning tracheostomy compared with those without it - 0.9 vs. 0.5% respectively. The causes of death were bleeding into tracheobronchial lumen and pulmonary embolism. The source of bleeding after tracheal resection was innominate artery. Overall incidence of postoperative complications was 2 times higher in tracheostomy patients compared with those without it - 22 (20%) vs. 26 (11.8%) cases respectively. Convalescence may be achieved in 89.8% patients after circular tracheal resection. Adverse long-term results are associated with postoperative complications. So their prevention and treatment will improve the

  17. Tracheal replacement by autogenous aorta.

    Science.gov (United States)

    Anoosh, Farhad; Hodjati, Hossain; Dehghani, Seifollah; Tanideh, Nader; Kumar, Perikala V

    2009-06-09

    Tracheal defects may occur after trauma or prolonged intubation. Resection of tracheal tumors also poses a major challenge for substitution. In an effort to solve this problem, different techniques have been tried with little success. We report on a new animal model which showed acceptable results with fewer complications. We replaced 5 cm of cervical trachea in 10 dogs with harvested infra-renal aorta and repaired the aortic defect with Dacron graft. Necropsy of the grafted aorta and anastomotic site revealed well healed anastomosis in all animals together with ciliated columnar epithelium coverage of grafted aorta and neovascularization of aortic wall. Aortic graft is preferable to other substitutes because of less antigenicity, less vascularity, and no mucous secretions or peristalsis.

  18. Tracheal rupture caused by blunt chest trauma: radiological and clinical features

    Energy Technology Data Exchange (ETDEWEB)

    Kunisch-Hoppe, M.; Rauber, K.; Rau, W.S. [Dept. of Diagnostic Radiology, Justus Liebig Univ., Giessen (Germany); Hoppe, M. [Dept. of Diagnostic Radiology, University Hospital, Philipps University, Marburg (Germany); Popella, C. [Dept. of ENT, Justus Liebig University, Giessen (Germany)

    2000-03-01

    The aim of this study was to assess radiomorphologic and clinical features of tracheal rupture due to blunt chest trauma. From 1992 until 1998 the radiomorphologic and clinical key findings of all consecutive tracheal ruptures were retrospectively analyzed. The study included ten patients (7 men and 3 women; mean age 35 years); all had pneumothoraces which were persistent despite suction drainage. Seven patients developed a pneumomediastinum as well as a subcutaneous emphysema on conventional chest X-rays. In five patients, one major hint leading to the diagnosis was a cervical emphysema, discovered on the lateral cervical spine view. Contrast-media-enhanced thoracic CT was obtained in all ten cases and showed additional injuries (atelectasis n = 5; lung contusion n = 4; lung laceration n = 2; hematothorax n = 2 and hematomediastinum n = 4). The definite diagnosis of tracheal rupture was made by bronchoscopy, which was obtained in all patients. Tracheal rupture due to blunt chest trauma occurs rarely. Key findings were all provided by conventional chest X-ray. Tracheal rupture is suspected in front of a pneumothorax, a pneumomediastinum, or a subcutaneous emphysema on lateral cervical spine and chest films. Routine thoracic CT could also demonstrate these findings but could not confirm the definite diagnosis of an tracheal rupture except in one case; in the other 9 cases this was done by bronchoscopy. Thus, bronchoscopy should be mandatory in all suspicious cases of tracheal rupture and remains the gold standard. (orig.)

  19. Tracheal rupture caused by blunt chest trauma: radiological and clinical features

    International Nuclear Information System (INIS)

    Kunisch-Hoppe, M.; Rauber, K.; Rau, W.S.; Hoppe, M.; Popella, C.

    2000-01-01

    The aim of this study was to assess radiomorphologic and clinical features of tracheal rupture due to blunt chest trauma. From 1992 until 1998 the radiomorphologic and clinical key findings of all consecutive tracheal ruptures were retrospectively analyzed. The study included ten patients (7 men and 3 women; mean age 35 years); all had pneumothoraces which were persistent despite suction drainage. Seven patients developed a pneumomediastinum as well as a subcutaneous emphysema on conventional chest X-rays. In five patients, one major hint leading to the diagnosis was a cervical emphysema, discovered on the lateral cervical spine view. Contrast-media-enhanced thoracic CT was obtained in all ten cases and showed additional injuries (atelectasis n = 5; lung contusion n = 4; lung laceration n = 2; hematothorax n = 2 and hematomediastinum n = 4). The definite diagnosis of tracheal rupture was made by bronchoscopy, which was obtained in all patients. Tracheal rupture due to blunt chest trauma occurs rarely. Key findings were all provided by conventional chest X-ray. Tracheal rupture is suspected in front of a pneumothorax, a pneumomediastinum, or a subcutaneous emphysema on lateral cervical spine and chest films. Routine thoracic CT could also demonstrate these findings but could not confirm the definite diagnosis of an tracheal rupture except in one case; in the other 9 cases this was done by bronchoscopy. Thus, bronchoscopy should be mandatory in all suspicious cases of tracheal rupture and remains the gold standard. (orig.)

  20. Percutaneous dilatational tracheostomy using the ETView Tracheoscopic Ventilation Tube®: a teaching course in a pig model.

    Science.gov (United States)

    Fiorelli, Alfonso; Ferraro, Fausto; Frongillo, Elisabetta; Fusco, Pierluigi; Pierdiluca, Matteo; Nagar, Francesca; Iuorio, Angela; Santini, Mario

    2017-10-01

    We planned a training course for trainees of different specialties with the aim of teaching the skills of a new procedure for performing percutaneous dilatational tracheostomy (PDT) with an ETView tracheoscopic ventilation tube instead of standard bronchoscopy in an ex vivo pig model. The endotracheal tube, with a camera-embedded tip, was used as an alternative to standard bronchoscopy for visualization of patient airways. The procedure was performed on a home-made animal model. The participants were asked to perform PDT in three different sessions to improve their dexterity. The primary endpoint was the reduction of complications seen during the different sessions of the training course. The secondary endpoint was the satisfaction of the participants as assessed by an anonymous survey. Thirty-seven residents in anesthesiology and 7 in thoracic surgery in the first 2 years of their training and without any confidence with percutaneous tracheostomy participated in the study. Tracheal cuff lesions and impalement of the tracheal tube were the most observed complications, and were concentrated in the early sessions. A significant reduction in complications and operative time was seen during the ongoing sessions of the course. No lesions of the posterior tracheal wall and only a ring fracture occurred during the last session of the course. All participants were satisfied with the course. Our course seems to confer the technical skills to perform percutaneous tracheostomy to trainees and instill confidence with the procedure. However, the experience acquired on a training course should be evaluated in clinical practice.

  1. Management of a case of left tracheal sleeve pneumonectomy under cardiopulmonary bypass: Anesthesia perspectives

    Directory of Open Access Journals (Sweden)

    Aman Jyoti

    2014-01-01

    Full Text Available The lung tumors with carinal involvement are frequently managed with tracheal sleeve pneumonectomy and tracheobronchial anastomosis without use of cardiopulmonary bypass (CPB. Various modes of ventilation have been described during tracheal resection and anastomosis. Use of CPB during this period allows the procedure to be conducted in a more controlled way. We performed tracheal sleeve pneumonectomy for adenoid cystic carcinoma of left lung involving carina. The surgery was performed in two stages. In the first stage, left pneumonectomy was performed and in the second stage after 48 h, tracheobronchial resection and anastomosis was performed under CPB. Second stage was delayed to avoid excessive bleeding (due to heparinization from the extensive vascular raw area left after pneumonectomy. Meticulous peri-operative planning and optimal post-operative care helped in successful management of a complex case, which is associated with high morbidity and mortality.

  2. Polyflex stenting of tracheomalacia after surgery for congenital tracheal stenosis.

    Science.gov (United States)

    Tibballs, James; Fasulakis, Stephen; Robertson, Colin F; Berkowitz, Robert G; Massie, John; Brizard, Christian; Rose, Elizabeth; Bekhit, Elhamy; Eyres, Robert; Ragg, Philip

    2007-01-01

    Polyflex self-expanding stents (Rüsch, Germany) were used in three young children who had presented with life-threatening long-segment tracheal stenosis with bronchial stenosis in two cases. Two children had slide tracheoplasties and subsequently aortic homografts and another tracheal resection and autotracheoplasty. However, in all cases persistent lower tracheal malacia necessitated stenting. Complications of granuloma, stent migration or dislodgement occurred in all cases. A fatal tracheo-aortic fistula occurred in one child. Granuloma in one was treated successfully with steroids. One child survives.

  3. Tracheal CT morphology: correlation with distribution and extent of thoracic adipose tissue

    Energy Technology Data Exchange (ETDEWEB)

    Ap Dafydd, Derfel [Imperial College Healthcare NHS Trust, Department of Radiology, Charing Cross Hospital, London (United Kingdom); Desai, Sujal R. [King' s College Hospital NHS Foundation Trust, King' s College London, King' s Health Partners, London (United Kingdom); Gordon, Fabiana; Copley, Susan J. [Imperial College, London (United Kingdom)

    2016-10-15

    To evaluate the relationship between adipose tissue measurements and anterior bowing of the posterior tracheal wall in a large nonselected group of patients undergoing CT pulmonary angiography (CTPA). Consecutive patients undergoing CTPA over a 4-month period were analyzed retrospectively. Using an adapted scoring system (posterior bowing, flattening, mild/moderate or severe anterior bowing of the posterior tracheal membrane), the axial morphology and cross-sectional area of the trachea at the narrowest point and 1 cm above the aortic arch were evaluated. Measurements of adipose tissue were taken (anterior mediastinal fat width, sagittal upper abdominal diameter and subcutaneous fat thickness at the level of the costophrenic angle). Relationships between tracheal morphology and measurements of adipose tissue were analyzed. 296 patients were included (120 males, 176 females, mean age 59 years, range 19-90). Severe anterior bowing of the posterior tracheal wall correlated with increasing sagittal upper abdominal diameter (p = 0.002). Mild/moderate and severe anterior bowing of the posterior tracheal wall correlated with increasing mediastinal fat width (p = 0.000 and p = 0.031, respectively). Tracheal cross-sectional area was inversely correlated with increasing subcutaneous fat thickness (p = 0.022). The findings demonstrate a statistically significant relationship between CT tracheal morphology and adipose tissue measurements in a large nonselected population. (orig.)

  4. Hippocrates (ca 460-375 bc), Introducing Thoracotomy Combined With a Tracheal Intubation for the Parapneumonic Pleural Effusions and Empyema Thoracis.

    Science.gov (United States)

    Tsoucalas, Gregory; Sgantzos, Markos

    2016-12-01

    Hippocrates was the first physician to describe in accuracy pleural effusion and pneumonia. To treat empyema thoracis he had introduced a combined method of tracheal intubation with a simultaneously thoracotomy. The surgical incision was used for the pus to be progressively drainaged. If the patient was too weak to eat, he had suggested for nutritional mixtures to be administered through an oral-gastric tube. Thus Hippocrates composed in his operating theatre, an icon similar to modern surgical operations. © The Author(s) 2016.

  5. Tracheal replacement by autogenous aorta

    Directory of Open Access Journals (Sweden)

    Anoosh Farhad

    2009-06-01

    Full Text Available Abstract Background Tracheal defects may occur after trauma or prolonged intubation. Resection of tracheal tumors also poses a major challenge for substitution. In an effort to solve this problem, different techniques have been tried with little success. We report on a new animal model which showed acceptable results with fewer complications. Methods We replaced 5 cm of cervical trachea in 10 dogs with harvested infra-renal aorta and repaired the aortic defect with Dacron graft. Results Necropsy of the grafted aorta and anastomotic site revealed well healed anastomosis in all animals together with ciliated columnar epithelium coverage of grafted aorta and neovascularization of aortic wall. Conclusion Aortic graft is preferable to other substitutes because of less antigenicity, less vascularity, and no mucous secretions or peristalsis

  6. Tracheal Chondrosarcoma: Systematic Review of Tumor Characteristics, Diagnosis, and Treatment Outcomes with Case Report

    Directory of Open Access Journals (Sweden)

    Emily A. Kutzner

    2017-01-01

    Full Text Available To our knowledge this is the first systematic review of tracheal chondrosarcoma treatment outcomes. Management insights are thoroughly discussed. Men constitute 93.8% of cases, and most of these occur in the distal trachea. The most common symptom, dyspnea, occurs in virtually all patients. Extratracheal extension had occurred in 78.6% of patients. Definitive treatment with tracheal resection showed no recurrences in 10 patients with mean follow-up of 3.1 years. Adjuvant radiotherapy may be utilized for improving local control when open complete resection cannot be performed, but only after endoscopic excision of gross tumor.

  7. Ciliated cells in vitamin A-deprived cultured hamster tracheal epithelium do divide

    International Nuclear Information System (INIS)

    Rutten, A.A.; Beems, R.B.; Wilmer, J.W.; Feron, V.J.

    1988-01-01

    The pseudostratified tracheal epithelium, composed of a heterogeneous phenotypically varying cell population, was studied with respect to the in vitro cell proliferative activity of differentiated epithelial cells. Ciliated tracheal epithelial cells so far have been considered to be terminally differentiated, nonproliferating cells. Tracheal organ cultures obtained from vitamin A-deprived Syrian Golden hamsters were cultured in a vitamin A-deficient, serum-free, hormone-supplemented medium. In vitamin A-deprived tracheal epithelium treated with physiologically active all-trans retinol and low cigarette-smoke condensate concentrations it is possible to stimulate the cell proliferation of both basal and columnar cells. Therefore, the probability of finding proliferating columnar cells was increased compared with the in vivo and the vitamin A-deprived situation in which cell proliferative activity is relatively low. In the presence of cigarette-smoke condensate in a noncytotoxic concentration, basal, small mucous granule, ciliated, and indifferent tracheal epithelial cells incorporated [methyl-3H]-thymidine into the DNA during the S phase. The finding that ciliated cells were labeled was supported by serial sections showing the same labeled ciliated cell in two section planes separated by 2 to 3 micron, without labeled epithelial cells next to the ciliated cell. Furthermore, a ciliated tracheal epithelial cell incorporating [methyl- 3 H]thymidine into DNA was also seen in tracheal cultures of vitamin A-deprived hamsters treated with all-trans retinol in a physiologic concentration

  8. Canine tracheal epithelial cells are more sensitive than rat tracheal epithelial cells to transforming growth factor beta induced growth inhibition

    International Nuclear Information System (INIS)

    Hubbs, A.F.; Hahn, F.F.; Kelly, G.; Thomassen, D.G.

    1988-01-01

    Transforming growth factor beta (TGFβ) markedly inhibited growth of canine tracheal epithelial (CTE) cells. Reduced responsiveness to TGFβ-induced growth inhibition accompanied neoplastic progression of these cells from primary to transformed to neoplastic. This was similar to the relationship between neoplastic progression and increased resistance to TGFβ-induced growth inhibition seen for rat tracheal epithelial (RTE) cells. The canine cells were more sensitive than rat cells to TGFβ-induced growth inhibition at all stages in the neoplastic process. (author)

  9. Comparative efficacy of Combination of Propofol or Thiopental with Remifentanil on Tracheal Intubation without Muscle Relaxants

    Directory of Open Access Journals (Sweden)

    k Naseri

    2007-10-01

    Full Text Available Introduction & Objective: In some medical situations administration of muscle relaxants after intravenous anesthetics for tracheal intubation may be unnecessary or sometimes could be hazardous. In such situations, replacing an alternative drug for the facilitation of tracheal intubation is obvious. Remifentanil is a short acting opioid drug which may be useful in solving this problem. The aim of this study was to compare the effects of propofol or thiopental in combination with remifentanil in the absence of muscle relaxants on larengoscopy and intubation conditions in general anesthesia. Materials & Methods: This is a randomized double-blind clinical trial which was performed in 1386 in Be’sat hospital of Sanandaj. Forty two ASA 1 and 2 patients recruited to receive propofol, 2 Mg/Kg, or thiopental, 5Mg/K. All patients received lidocaine, 1.5 Mg/Kg, and remifentanil, 2.5 µg/Kg, 30 seconds before anesthetics administration. larengoscopy and tracheal intubation were done 90 seconds after induction of anesthesia. On the basis of mask ventilation, jaw relaxation, vocal cords position and patient's response to intubations and endotracheal tube cuff inflation the intubation conditions were assessed and recorded as excellent, good ,acceptable or poor. The mean arterial pressure and heart rate were measured before and after anesthetics administration and also 45 seconds and two and five minutes after intubations. Data were analyzed by X2, fisher exact test ant student T-test using SPSS software. Results: Excellent or good larengoscopy and intubation conditions were observed in 9 (%42.9 of thiopental patients and 20 (%95.2 of propofol patients (p<0.05. Mean arterial pressure and heart rate decreased more significantly in propofol group in comparison with the thiopental group (p<0.05. Conclusion: Combination of remifentanil and propofol or thiopental could facilitate ventilation via face mask in all patients. Although combination of propofol and

  10. In vitro evaluation of the method effectiveness to limit inflation pressure cuffs of endotracheal tubes

    Directory of Open Access Journals (Sweden)

    Rafael de Macedo Coelho

    2016-04-01

    Full Text Available ABSTRACT BACKGROUND AND OBJECTIVE: Cuffs of tracheal tubes protect the lower airway from aspiration of gastric contents and facilitate ventilation, but may cause many complications, especially when the cuff pressure exceeds 30 cm H2O. This occurs in over 30% of conventional insufflations, so it is recommended to limit this pressure. In this study we evaluated the in vitro effectiveness of a method of limiting the cuff pressure to a range between 20 and 30 cm H2O. METHOD: Using an adapter to connect the tested tube to the anesthesia machine, the relief valve was regulated to 30 cm H2O, inflating the cuff by operating the rapid flow of oxygen button. There were 33 trials for each tube of three manufacturers, of five sizes (6.5-8.5, using three times inflation (10, 15 and 20 s, totaling 1485 tests. After inflation, the pressure obtained was measured with a manometer. Pressure >30 cm H2O or <20 cm H2O were considered failures. RESULTS: There were eight failures (0.5%, 95% CI: 0.1-0.9%, with all by pressures <20 cm H2O and after 10 s inflation (1.6%, 95% CI: 0 5-2.7%. One failure occurred with a 6.5 tube (0.3%, 95% CI: -0.3 to 0.9%, six with 7.0 tubes (2%, 95% CI: 0.4-3.6%, and one with a 7.5 tube (0.3%, 95% CI: -0.3 to 0.9%. CONCLUSION: This method was effective for inflating tracheal tube cuffs of different sizes and manufacturers, limiting its pressure to a range between 20 and 30 cm H2O, with a success rate of 99.5% (95% CI: 99.1-99.9%.

  11. Avoidance versus use of neuromuscular blocking agents for improving conditions during tracheal intubation or direct laryngoscopy in adults and adolescents

    DEFF Research Database (Denmark)

    Lundstrøm, Lars Hyldborg; Duez, Christophe Hv; Nørskov, Anders Kehlet

    2017-01-01

    ) for adults and adolescents allocated to tracheal intubation with direct laryngoscopy. To look at various outcomes, conduct subgroup and sensitivity analyses, examine the role of bias, and apply trial sequential analysis (TSA) to examine the level of available evidence for this intervention. SEARCH METHODS......: We searched CENTRAL, MEDLINE, Embase, BIOSIS, International Web of Science, LILACS, advanced Google, CINAHL, and the following trial registries: Current Controlled Trials; ClinicalTrials.gov; and www.centerwatch.com, up to January 2017. We checked the reference lists of included trials and reviews...... the best conditions for tracheal intubation and may reduce the risk of upper airway discomfort or injury following tracheal intubation. Study results were characterized by indirectness, heterogeneity, and high or uncertain risk of bias concerning our primary outcome describing difficult tracheal intubation...

  12. Comparison of pulsed fluoroscopy by direct control using a grid-controlled x-ray tube with pulsed fluoroscopy by primary control

    International Nuclear Information System (INIS)

    Chida, Koichi; Zuguchi, Masayuki; Ito, Daisuke; Sato, Kunihiko; Shimura, Hirotaka; Sasaki, Masatoshi

    2001-01-01

    Interventional radiology (IVR) procedures may involve high radiation doses that are potentially harmful to the patient. In IVR procedures, pulsed fluoroscopy can greatly decrease the radiation that the physician and patient receive. There are two types of pulsed fluoroscopy: direct control and primary (indirect) control. The purpose of this study was to compare pulsed fluoroscopy by direct control, using a grid-controlled x-ray tube, with pulsed fluoroscopy using primary control. For both types of pulsed fluoroscopy, we measured the waveforms (x-ray tube voltage, x-ray tube current, and x-ray output) and the relative radiation dose. In addition, we compared the decrease in radiation during pulsed fluoroscopy using a care filter. The studies were performed using a Siemens Bicor Plus x-ray System (direct control) and a Siemens Multistar Plus x-ray System (primary control). Using primary pulse control, a 50% decrease in the x-ray output waveform took approximately 0.5-1.0 msec, or longer with a lower x-ray tube current. Using direct pulse control, a 50% decrease in the x-ray output waveform took approximately 0.1 msec, and was independent of x-ray tube current. The rate of radiation reduction with primary pulse control using the care filter with a lower x-ray tube current had a slope exceeding 10%. Pulsed fluoroscopy by direct control using a grid-controlled x-ray tube permits an optimal radiation dose. To decrease the radiation in primary pulse control, a care filter must be used, particularly with a lower x-ray tube current. (author)

  13. Tubeless tracheal resection and reconstruction for management of benign stenosis.

    Science.gov (United States)

    Caronia, Francesco Paolo; Loizzi, Domenico; Nicolosi, Tommaso; Castorina, Sergio; Fiorelli, Alfonso

    2017-12-01

    We reported a tubeless tracheal resection and reconstruction for the management of benign posttracheostomy tracheal stenosis. A 34-year-old man with stridor, severe respiratory distress, and recurrent pneumonia was referred to our attention for treatment of benign posttracheostomy tracheal stenosis. As he refused general anesthesia, the procedure was performed while he was under local anesthesia and spontaneous ventilation. Sedation was started with infusion of dexmedetomidine 0.7 mg/kg/min and of remifentanil 0.5 mg/kg/h; also, 40%-50% oxygen was delivered using a laryngeal mask at a rate of 3.5 mL/min. An additional dose of 2% lidocaine was injected into the surgical site during the operation to achieve an adequate level of anesthesia. A standard resection and reconstruction of trachea was carried out and no recurrence was found in the follow-up of 41 months. Tubeless tracheal surgery seems to be a feasible and safe procedure. Larger prospective series should validate our results. © 2017 Wiley Periodicals, Inc.

  14. Modeling, Prediction, and Control of Heating Temperature for Tube Billet

    Directory of Open Access Journals (Sweden)

    Yachun Mao

    2015-01-01

    Full Text Available Annular furnaces have multivariate, nonlinear, large time lag, and cross coupling characteristics. The prediction and control of the exit temperature of a tube billet are important but difficult. We establish a prediction model for the final temperature of a tube billet through OS-ELM-DRPLS method. We address the complex production characteristics, integrate the advantages of PLS and ELM algorithms in establishing linear and nonlinear models, and consider model update and data lag. Based on the proposed model, we design a prediction control algorithm for tube billet temperature. The algorithm is validated using the practical production data of Baosteel Co., Ltd. Results show that the model achieves the precision required in industrial applications. The temperature of the tube billet can be controlled within the required temperature range through compensation control method.

  15. Tracheal Penetration and Tracheoesophageal Fistula Caused by an Esophageal Self-Expanding Metallic Stent

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2014-01-01

    Full Text Available Tracheal penetration of esophageal self-expanding metallic stents (SEMS with/without tracheoesophageal fistula (TEF formation is a rare occurrence. We report the case of a 66-year-old female patient with advanced esophageal squamous cell carcinoma who had undergone palliative esophageal stenting on three occasions for recurrent esophageal stent obstruction. On evaluation of symptoms of breathing difficulty and aspiration following third esophageal stent placement, tracheal erosion and TEF formation due to the tracheal penetration by esophageal stent were diagnosed. The patient was successfully managed by covered tracheal SEMS placement under flexible bronchoscopy.

  16. Stent placement for tracheal stenosis in patients with esophageal cancer

    International Nuclear Information System (INIS)

    Takagi, Keigo; Hata, Yoshinobu; Sasamoto, Shuichi; Takahashi, Shoji; Sato, Fumitomo; Tamaki, Kazuyoshi; Goto, Hidenori; Yuasa, Rena

    2011-01-01

    Tracheal invasion including tracheal bifurcation due to esophageal cancer can sometimes cause serious complications of the airway, but such cases sometimes improve quickly following chemoradiation treatment. The absolute indications for stent replacement in the airway for this disorder and the optimal choice of stent are herein discussed. Between 1992 and 2010, 28 patients with airway stenosis, including 7 patients with esophago-tracheal fistula, were treated by placement of various stents; namely, 12 patients received Dumon stents, 3 patients had Dynamic stents, 10 patients were given Ultraflex stents, while 3 other patients were treated without the use of stents. Severe dyspnea in the supine position was observed, which mainly originated from invasion to the membranous portion of the trachea. Airway patency was maintained after stent replacement, although the median survival time of such cases was only 4 months. Three patients with severe dyspnea who could lie in a supine position recovered after undergoing chemoradiation treatment without stent replacement. No cases of stent removal were observed after chemoradiation treatment. Chemoradiation treatment for esophageal cancer was found to be effective for the management of airway disturbances, and thus the absolute indications for stent replacement are restricted to patients who cannot lie in a supine position due to severe impairment of ventilation during radiation therapy, as well as patients presenting with tracheobroncho-esophageal fistula. Concerning stent selection, a metal stent should be the first choice for tracheal stenosis due to its ease of insertion, because there is no substantial difference between silicone and metal stents regarding the treatment of tracheal stenosis. However, it is important to note that a silicone Y stent is useful for the treatment of tracheal bifurcation. (author)

  17. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  18. Experimental study of different nickel-titanium memory tracheal stents in dogs

    International Nuclear Information System (INIS)

    Lang Xu; He Nengshu; Fan Hailun

    2009-01-01

    Objective: Since membrane -covered metal tracheal stent was applied successfully to treat the airway stenosis, it has been widely used and obtained satisfactory result during the past years. The purpose of our study was provide theoretical rational for treatment with membrane-covered tracheal stent by using animal experiment. Methods: The nickel- titanium memory stents of 22 mm in diameter and 6 cm in length were deployed in 18 dogs. The dogs were grouped into full- length membrane-covered group (n=6), partial-length membrane-covered group (membrane was covered for 4 cm in the medial part of the stent, n=6), and naked stent group (n=6). After the stent placement dysphagia or dysphonia was monitored daily. Twenty-four weeks later, the dogs were executed. Speiments were taken from the cephalic, medial, and caudal trachea under the stent. HE stain and proliferating cell nuclear antigen (PCNA) were evaluated. Results: After the stent placement, no dyspnea, dysphagia or dysphonia but cough was present in each dog. There was no significant difference in symptom between the three groups. Inflammation reaction, metaplasia from low columnar epithelium to spuamous epithelium, and mild granulation tissue hyperplasia in the underlying mucosa were present in each group. However, fibrosis and tracheal straitness were present only in the non-membrane-covered area, but not in the membrane-covered area. More PCNA expression was observed in the non-membrane -covered area than in the membrane-covered area. Conclusion: Both membrane-covered and non-membrane-covered stents can cause similar symptoms. However, the membrane -covered tracheal stent has good biological compatibility and would not induce tracheal straitness. The non-membrane -covered tracheal stent could induce a severe pathologic reaction and tracheal straitness. (authors)

  19. Effect of rocuronium on the bispectral index under anesthesia and tracheal intubation.

    Science.gov (United States)

    Yue, Hui; Han, Jinyu; Liu, Ling; Wang, Kaiyuan; Li, Jincheng

    2016-12-01

    The aim of the present study was to investigate the effect of various doses of rocuronium on bispectral index (BIS) responses to propofol induction and tracheal intubation, as well as the role of the non-depolarization muscle relaxant rocuronium on the depth of sedation. A total of 72 patients (American Society of Anesthesiologists physical status I-II) were anaesthetized with propofol using a target-controlled infusion, and randomly divided into two sedation level groups (n=36). The patients were divided into 2 groups according to the BIS value: A normal sedation group (group 1), with a stable BIS value at 40-60, and a deep sedation group (group 2), with a BIS value rocuronium (0.3, 0.6, 0.9 and 1.2 mg/kg). Tracheal intubation was performed after 2 min of rocuronium administration. BIS, electromyography (EMG), heart rate (HR) and mean arterial pressure (MAP) were recorded continuously and averaged over 1 min during baseline (T1), steady state (T2), 2 min after rocuronium infusion (T3), and 0, 2 and 5 min after tracheal intubation. The results demonstrated that HR and MAP decreased significantly at T2 and T3 compared with T1. Following tracheal intubation (L0), HR and MAP significantly increased compared with T2 and T3, and returned to levels similar to those prior to intubation after 5 min. In group 1C and 1D, BIS was significantly decreased at T3 compared with T2; BIS was significantly increased at L0 compared with T3 in group 1A and 1B. EMG at earlier stages of anesthesia was significantly higher compared with other points, and was significantly increased at L0 compared with T3 in group 1A and 1B. These results demonstrated that BIS response may be associated with the dosage of rocuronium in the normal sedation group, although no association was observed with the deep sedation group. Tracheal intubation resulted in marked hemodynamic changes under both normal and deep sedation.

  20. Control rod guide tube assembly

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1982-01-01

    An improved fuel assembly is described as consisting of a sleeve that engages one end of a control rod guide tube essentially fixing the guide tube to one of the fuel assembly end structures. The end of the sleeve protrudes above the surface of the end fitting. The outer surface of the sleeve has a peripheral groove that engages the resilient sides of a cellular grid or lattice shaped lock. This lock fixes the sleeve in position between the various elements that comprise the end fitting, thereby eliminating a profusion of costly and potentially troublesome nuts, threaded studs and the like that are frequently employed in the fuel assemblies that are presently in use

  1. Awake tracheal intubation using Pentax airway scope in 30 patients: A Case series

    Directory of Open Access Journals (Sweden)

    Payal Kajekar

    2014-01-01

    Full Text Available Background and Aims: Pentax airway scope (AWS has been successfully used for managing difficult intubations. In this case series, we aimed to evaluate the success rate and time taken to complete intubation, when AWS was used for awake tracheal intubation. Methods: We prospectively evaluated the use of AWS for awake tracheal intubation in 30 patients. Indication for awake intubation, intubation time, total time to complete tracheal intubation, laryngoscopic view (Cormack and Lehane grade, total dose of local anaesthetic used, anaesthetists rating and patient′s tolerance of the procedure were recorded. Results: The procedure was successful in 25 out of the 30 patients (83%. The mean (standard deviation intubation time and total time to complete the tracheal intubation was 5.4 (2.4 and 13.9 (3.7 min, respectively in successful cases. The laryngeal view was grade 1 in 24 and grade 2 in one of 25 successful intubations. In three out of the five patients where the AWS failed, awake tracheal intubation was successfully completed with the assistance of flexible fibre optic scope (FOS. Conclusion: Awake tracheal intubation using AWS was successful in 83% of patients. Success rate can be further improved using a combination of AWS and FOS. Anaesthesiologists who do not routinely use FOS may find AWS easier to use for awake tracheal intubation using an oral route.

  2. Gastric Tube Reconstruction with Superdrainage Using Indocyanine Green Fluorescence During Esophagectomy.

    Science.gov (United States)

    Kitagawa, Hiroyuki; Namikawa, Tsutomu; Iwabu, Jun; Hanazaki, Kazuhiro

    2017-01-01

    We report a case of gastric tube reconstruction with superdrainage using indocyanine green fluorescence during esophagectomy for esophageal cancer. A 53-year-old man with a history of early esophageal cancer treated with endoscopic mucosal dissection experienced esophageal cancer recurrence. There was no evidence of lymph node involvement or distant metastasis on computed tomography; therefore, we performed thoracoscopic esophagectomy. After thoracoscopic esophagectomy, we created a gastric tube. When pulling up the gastric tube through the post-mediastinum route, a root of the right gastroepiploic vein was injured. We subsequently performed superdrainage to avoid congestion of the gastric tube with omental vein and pre-tracheal vein anastomosis at the neck, and confirmed venous flow using the indocyanine green fluorescence method. No postoperative anastomotic leakage was observed, and the patient was discharged 22 days after surgery. Thus, we recommend the indocyanine green fluorescence method in cases involving superdrainage during esophagectomy. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  3. Tracheal anastomosis using indocyanine green dye enhanced fibrinogen with a near-infrared diode laser

    Science.gov (United States)

    Auteri, Joseph S.; Jeevanandam, Valluvan; Oz, Mehmet C.; Libutti, Steven K.; Kirby, Thomas J.; Smith, Craig R.; Treat, Michael R.

    1990-06-01

    A major obstacle to lung transplantation and combined heart- lung transplantation is dehiscence of the tracheobronchial anastomosis. We explored the possibility of laser welded anastomoses in canine tracheas in vivo. Laser anastomoses were performed on three-quarter circumferential anterior tracheotomies. A continous wave diode laser (808 +1 nm) at a power density of 9.6 watts/cm was used. Human fibrinogen was mixed with indocyanine green dye (ICG, max absorbance 805 nm) and applied to the anastomosis site prior to laser exposure. Animals were sacrificed at 0, 21 and 28 days post-operatively. At sacrifice weld bursting pressures were measured by raising intratracheal pressure using forced ventilation via an endotracheal tube. Sutured and laser welded anastomoses had similar bursting pressures, and exhibited satisfactory histologic evidence of healing. However, compared to polypropylene sutured controls, the laser welded anastomoses exhibited less peritracheal inflammatory reaction and showed visibly smoother luminal surfaces at 21 and 28 days post- operatively. Tracheal anastomosis using ICG dye enhanced fibrinogen combined with the near-infrared diode laser is a promising extension of the technology of laser tissue fusion and deserves further study.

  4. 21 CFR 878.3720 - Tracheal prosthesis.

    Science.gov (United States)

    2010-04-01

    ...) Identification. The tracheal prosthesis is a rigid, flexible, or expandable tubular device made of a silicone... of the trachea or trachealbronchial tree. It may be unbranched or contain one or two branches. The...

  5. Failed tracheal intubation using a laryngoscope and intubating laryngeal mask.

    Science.gov (United States)

    Asai, T; Hirose, T; Shingu, K

    2000-04-01

    To report unexpected failed tracheal intubation using a laryngoscope and an intubating laryngeal mask, and difficult ventilation via a facemask, laryngeal mask and intubating laryngeal mask, in a patient with an unrecognized lingual tonsillar hypertrophy. A 63-yr-old woman, who had undergone clipping of an aneurysm seven weeks previously, was scheduled for ventriculo-peritoneal shunt. At the previous surgery, there had been no difficulty in ventilation or in tracheal intubation. Her trachea remained intubated nasally for 11 days after surgery. Preoperatively, her consciousness was impaired. There were no restrictions in head and neck movements or mouth opening. The thyromental distance was 7 cm. After induction of anesthesia, manual ventilation via a facemask with a Guedel airway was suboptimal and the chest expanded insufficiently. At laryngoscopy using a Macintosh or McCoy device, only the tip of the epiglottis, but not the glottis, could be seen, and tracheal intubation failed. There was a partial obstruction during manual ventilation through either the intubating laryngeal mask or conventional laryngeal mask; intubation through each device failed. Digital examination of the pharynx, after removal of the laryngeal mask, indicated a mass occupying the vallecula. Lingual tonsillar hypertrophy (1 x 1 x 2 cm) was found to be the cause of the failure. Awake fibrescope-aided tracheal intubation was accomplished. Unexpected lingual tonsillar hypertrophy can cause both ventilation and tracheal intubation difficult, and neither the laryngeal mask nor intubating laryngeal mask may be helpful in the circumstances.

  6. Congenital tracheal defects: embryonic development and animal models

    Directory of Open Access Journals (Sweden)

    Zenab Arooj Sher

    2016-03-01

    Full Text Available Tracheal anomalies are potentially catastrophic congenital defects. As a newborn begins to breathe, the trachea needs to maintain an appropriate balance of elasticity and rigidity. If the tracheal cartilages are disorganized or structurally weak, the airways can collapse, obstructing breathing. Cartilage rings that are too small or too rigid can also obstruct breathing. These anomalies are frequently associated with craniofacial syndromes, and, despite the importance, are poorly understood. In this review, we summarize the spectrum of pathological phenotypes of the trachea and correlate them with the molecular events uncovered in mouse models.

  7. Vicks VapoRub induces mucin secretion, decreases ciliary beat frequency, and increases tracheal mucus transport in the ferret trachea.

    Science.gov (United States)

    Abanses, Juan Carlos; Arima, Shinobu; Rubin, Bruce K

    2009-01-01

    Vicks VapoRub (VVR) [Proctor and Gamble; Cincinnati, OH] is often used to relieve symptoms of chest congestion. We cared for a toddler in whom severe respiratory distress developed after VVR was applied directly under her nose. We hypothesized that VVR induced inflammation and adversely affected mucociliary function, and tested this hypothesis in an animal model of airway inflammation. [1] Trachea specimens excised from 15 healthy ferrets were incubated in culture plates lined with 200 mg of VVR, and the mucin secretion was compared to those from controls without VVR. Tracheal mucociliary transport velocity (MCTV) was measured by timing the movement of 4 microL of mucus across the trachea. Ciliary beat frequency (CBF) was measured using video microscopy. [2] Anesthetized and intubated ferrets inhaled a placebo or VVR that was placed at the proximal end of the endotracheal tube. We evaluated both healthy ferrets and animals in which we first induced tracheal inflammation with bacterial endotoxin (a lipopolysaccharide [LPS]). Mucin secretion was measured using an enzyme-linked lectin assay, and lung water was measured by wet/dry weight ratios. [1] Mucin secretion was increased by 63% over the controls in the VVR in vitro group (p < 0.01). CBF was decreased by 35% (p < 0.05) in the VVR group. [2] Neither LPS nor VVR increased lung water, but LPS decreased MCTV in both normal airways (31%) and VVR-exposed airways (30%; p = 0.03), and VVR increased MCTV by 34% in LPS-inflamed airways (p = 0.002). VVR stimulates mucin secretion and MCTV in the LPS-inflamed ferret airway. This set of findings is similar to the acute inflammatory stimulation observed with exposure to irritants, and may lead to mucus obstruction of small airways and increased nasal resistance.

  8. Relaxant effects of Ocimum basilicum on guinea pig tracheal chains and its possible mechanism(s

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Boskabady

    2005-01-01

    Full Text Available Therapeutic effects of Ocimum basilicum on respiratory diseases especially dyspnea have been reported in Iranian ancient medical books. In the present study, the relaxant effects of macerated and soxhlet extracts of this plant on tracheal chains of guinea pigs were evaluated. The relaxant effects of 4 cumulative concentrations of macerated and soxhlet extracts (0.25, 0.5, 0.75 and 1.0 W/V in comparison with saline as negative control and 4 cumulative concentrations of theophylline (0.25, 0.5, 0.75, and 1.0 mM as positive control were examined on precontracted tracheal chains of two groups of 6 guinea pig by 60 mM KCl (group 1 and 10 µM methacholine (group 2. Decrease in contractile tone of tracheal chains was considered as relaxant effect. In group 1 experiments only the last two higher concentrations of theophylline showed significant relaxant effect compared to that of saline (p<0.001 for both concentrations, which were significantly greater than those of macerated and soxhlet extracts (p<0.001 for all cases and in group 2 experiments both macerated and soxhlet extracts showed concentrationdependent relaxant effects compared to that of saline (p<0.05 to p<0.001 for both extracts. There were significant differences between the relaxant effects of both extracts with those of theophylline in group 2 experiments (p<0.01 to p<0.001. The relaxant effects of macerated and soxhlet extracts in group 1 were significantly lower than those of groups 2. These results showed a potent relaxant effect of Ocimum basilicum on tracheal chains of guinea pigs which were lower than theophylline at concentrations used.

  9. [Anesthetic management of a patient with Creutzfeldt-Jacob disease undergoing tracheal separation].

    Science.gov (United States)

    Kanzaki, Rieko; Hamada, Hiroshi; Fukuda, Hideki; Kawamoto, Masashi

    2012-10-01

    We gave anesthesia for tracheal separation in a patient with Creutzfeldt-Jakob disease. The patient, a 33-year-old woman, was bedridden and unable to communicate, and was going to undergo a tracheal separation procedure for repeated bouts of aspiration pneumonia. After a tracheostomy with local anesthesia and sedation with propofol, general anesthesia was induced and maintained with propofol (1.5-3.0 microg x ml(-1), target controlled infusion) and remifentanil (0.05-0.15 microg x kg(-1) x min(-1)). We did not use an anesthetic apparatus from the standpoint of infection control, and provided manual ventilation with a disposable Jackson-Rees circuit. During the operation, an entropy monitor indicated alternating extremely low (0-10) and high (90-100) values without circulatory change, probably due to a previously existing electroencephalographic abnormality. The surgery was uneventful, and spontaneous breathing and eyelid opening occurred about 10 minutes after discontinuation of remifentanil and propofol. In such infected patients, abnormal prion proteins can exist outside of the central nervous system throughout the period of anesthetic management. Therefore, careful infection control must be undertaken, even if the surgical site is not directly related to the central nervous system.

  10. Method of reactivity control in pressure tube reactor

    International Nuclear Information System (INIS)

    Fukumura, Nobuo.

    1988-01-01

    Purpose: To provide a method of controlling reactivity in a pressure tube reactor at high conversion ratio intended for high burn-up degree. Method: Control tubes are inserted in heavy water moderator. Light water is filled in the tubes at the initial burning stage. Along with the advance of the burning, the light water is gradually removed and replaced with gases of less reactive nuclear reactivity with neutrons such as air or gaseous carbon dioxide. The tubes are made of less neutron absorbing material such as aluminum. By filling light water, infinite multiplication factor is reduced to suppress the reactivity at the initial burning stage. As light water is gradually removed and replaced with air, etc., it provides an effect like that elimination of heavy water moderator to increase the conversion ratio. Accordingly, nuclear fission materials are produced additionally by so much to extend the burn-up degree. In this way, it can provide excellent effect in realizing high burn-up ratio and high conversion ratio. (Kamimura, M.)

  11. New CO2 laser waveguide systems: advances in surgery of tracheal stenosis

    Science.gov (United States)

    Stasche, Norbert; Bernecker, Frank; Hoermann, Karl

    1996-01-01

    The carbon dioxide laser is a well established tool in the surgical treatment of laryngeal and tracheal stenosis. Usually the laser beam is applied by a microscope/micromanipulator device. Different types of rigid laryngoscopes and bronchoscopes provide access to nearly every area of larynx, trachea and main bronchi. In order to be treated with this equipment the target tissue has to be in a straight optical axis with the laser beam output at the micromanipulator. We report about one patient who presented with severe dyspnea due to granulation tissue directly below his left vocal cord. He was suffering from tracheomalacia for several years and was successfully treated by tracheostomy and a Montgomery's silicone T-tube as a stent. Then granulation tissue blocked the upper orifice of the Montgomery's T-tube. First removal by a carbon dioxide laser beam through the laryngoscope would have required sacrificing his intact left vocal cord. We removed the obstructing tissue by using the ArthroLaseTM System: the carbon dioxide laser beam was conducted through a 90 degree bent rigid probe, using the tracheostomy as an access. This ArthroLaseTM System was originally designed for arthroscopic surgery. In this special case however it successfully extends the use of the carbon dioxide laser in otolaryngology.

  12. Use of the covered Y-shaped metallic stent in the treatment of airway stenoses involving the lower trachea and the tracheal carina: preliminary clinical study

    International Nuclear Information System (INIS)

    Yang Ruimin; Li Fenbao; Zhang Mingqiu; Wu Gang; Han Xinwei

    2007-01-01

    Objective: To describe a new kind of Y-shaped metallic stent delivery system and evaluate its feasibility and preliminary effect for managing multiple airway stenoses involving the lower trachea and the tracheal carina. Methods: The Y-shaped metallic stent delivery system consisted of three-tier structure. The inner-tier was composed of four parallel guiding tubes, which was used for two guidewires and two threads passing through, the middle-tier was delivery catheter, which contained the four guiding tubes, and the outer-tier was introducer sheath. Under the fluoroscopic guidance, 15 patients with multiple stenoses involving the lower trachea and the tracheal carina were treated with the new covered self-expandable Y-shaped metallic stents. Results: Stent placement in the tracheo-bronchial tree was technically successful in all patients with obliteration of the dyspnea immediately after stent placement, and SaO2 was increased form preoperative 75%-89% to postoperative 96%-99%. During follow-up a period of 3-58 weeks (M 22 weeks), all stenosis were resolved without stent-related complications, and the general physical of all 15 patents was improved with no occurrence of obviously dyspnea and bleeding. Karnofsky performance status (KPS) was improved from preoperative 26%-45% to postoperative 72%-95%. Five patients died of the following causes unrelated to stent insertion: multiple organ failure (n=3), cachexia (n=1) and pulmonary infection caused by gastrobronehial fistula (n=1), and the remaining 10 patients were alive with no evidence of dyspnea at the time of this report. Conclusion: Deployment of the covered Y-shaped metallic stent with the use of Y metallic stent delivery system in the management of airway stenoses involving the lower trachea and the tracheal carina was a simple and safe procedure and with a good short-term clinical efficacy. (authors)

  13. Use of the covered Y-shaped metallic stent in the treatment of airway stenoses involving the lower trachea and the tracheal carina: preliminary clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Ruimin, Yang; Fenbao, Li; Mingqiu, Zhang [Department of Intervention, First Affiliated Hospital, Xinxiang Medical Univ., Xinxiang (China); Gang, Wu; Xinwei, Han

    2007-09-15

    Objective: To describe a new kind of Y-shaped metallic stent delivery system and evaluate its feasibility and preliminary effect for managing multiple airway stenoses involving the lower trachea and the tracheal carina. Methods: The Y-shaped metallic stent delivery system consisted of three-tier structure. The inner-tier was composed of four parallel guiding tubes, which was used for two guidewires and two threads passing through, the middle-tier was delivery catheter, which contained the four guiding tubes, and the outer-tier was introducer sheath. Under the fluoroscopic guidance, 15 patients with multiple stenoses involving the lower trachea and the tracheal carina were treated with the new covered self-expandable Y-shaped metallic stents. Results: Stent placement in the tracheo-bronchial tree was technically successful in all patients with obliteration of the dyspnea immediately after stent placement, and SaO2 was increased form preoperative 75%-89% to postoperative 96%-99%. During follow-up a period of 3-58 weeks (M 22 weeks), all stenosis were resolved without stent-related complications, and the general physical of all 15 patents was improved with no occurrence of obviously dyspnea and bleeding. Karnofsky performance status (KPS) was improved from preoperative 26%-45% to postoperative 72%-95%. Five patients died of the following causes unrelated to stent insertion: multiple organ failure (n=3), cachexia (n=1) and pulmonary infection caused by gastrobronehial fistula (n=1), and the remaining 10 patients were alive with no evidence of dyspnea at the time of this report. Conclusion: Deployment of the covered Y-shaped metallic stent with the use of Y metallic stent delivery system in the management of airway stenoses involving the lower trachea and the tracheal carina was a simple and safe procedure and with a good short-term clinical efficacy. (authors)

  14. Welded tracheal stent removal in a child under cardiopulmonary bypass.

    Science.gov (United States)

    Kao, S C; Chang, W K; Pong, M W; Cheng, K W; Chan, K H; Tsai, S K

    2003-08-01

    Metallic tracheal stents have been used in the treatment of paediatric tracheomalacia for more than a decade. We describe a case in which critical airway obstruction occurred during removal of a welded tracheal stent using a rigid bronchoscope under general anaesthesia. Life-saving cardiopulmonary bypass was instituted urgently, and the welded stent was then removed successfully by directly opening the trachea.

  15. Low-Dose or High-Dose Rocuronium Reversed with Neostigmine or Sugammadex for Cesarean Delivery Anesthesia: A Randomized Controlled Noninferiority Trial of Time to Tracheal Intubation and Extubation.

    Science.gov (United States)

    Stourac, Petr; Adamus, Milan; Seidlova, Dagmar; Pavlik, Tomas; Janku, Petr; Krikava, Ivo; Mrozek, Zdenek; Prochazka, Martin; Klucka, Jozef; Stoudek, Roman; Bartikova, Ivana; Kosinova, Martina; Harazim, Hana; Robotkova, Hana; Hejduk, Karel; Hodicka, Zuzana; Kirchnerova, Martina; Francakova, Jana; Obare Pyszkova, Lenka; Hlozkova, Jarmila; Sevcik, Pavel

    2016-05-01

    Rocuronium for cesarean delivery under general anesthesia is an alternative to succinylcholine for rapid-sequence induction of anesthesia because of the availability of sugammadex for reversal of neuromuscular blockade. However, there are no large well-controlled studies in women undergoing general anesthesia for cesarean delivery. The aim of this noninferiority trial was to determine whether rocuronium and sugammadex confer benefit in time to tracheal intubation (primary outcome) and other neuromuscular blockade outcomes compared with succinylcholine, rocuronium, and neostigmine in women undergoing general anesthesia for cesarean delivery. We aimed to enroll all women undergoing general anesthesia for cesarean delivery in the 2 participating university hospitals (Brno, Olomouc, Czech Republic) in this single-blinded, randomized, controlled study. Women were randomly assigned to the ROC group (muscle relaxation induced with rocuronium 1 mg/kg and reversed with sugammadex 2-4 mg/kg) or the SUX group (succinylcholine 1 mg/kg for induction, rocuronium 0.3 mg/kg for maintenance, and neostigmine 0.03 mg/kg for reversal of the neuromuscular blockade). The interval from the end of propofol administration to tracheal intubation was the primary end point with a noninferiority margin of 20 seconds. We recorded intubating conditions (modified Viby-Mogensen score), neonatal outcome (Apgar score rocuronium for rapid-sequence induction is noninferior for time to tracheal intubation and is accompanied by more frequent absence of laryngoscopy resistance and lower incidence of myalgia in comparison with succinylcholine for cesarean delivery under general anesthesia.

  16. Research on temperature control and influence of the vacuum tubes with inserted tubes solar heater

    Science.gov (United States)

    Xiao, L. X.; He, Y. T.; Hua, J. Q.

    2017-11-01

    A novel snake-shape vacuum tube with inserted tubes solar collector is designed in this paper, the heat transfer characteristics of the collector are analyzed according to its structural characteristics, and the influence of different working temperature on thermal characteristics of the collector is studied. The solar water heater prototype consisting of 14 vacuum tubes with inserted tubes is prepared, and the hot water storage control subsystem is designed by hysteresis comparison algorithm. The heat characteristic of the prototype was experimentally studied under hot water output temperature of 40-45°C, 50-55°C and 60-65°C. The daily thermal efficiency was 64%, 50% and 46%, respectively. The experimental results are basically consistent with the theoretical analysis.

  17. http://www.bioline.org.br/js 104 Penetrating Tracheal Injuries – A ...

    African Journals Online (AJOL)

    jen

    airway and prompt repair is the mainstay of management of penetrating tracheal injuries. Introduction ... tracheal injury was made in the 16th century ... Pearson 7 Harrington8 Sheely9 and Hood10 ..... Ed Am Col Surg (Chicago) .p.391. 12.

  18. Radiation response of perfused tracheal sections

    International Nuclear Information System (INIS)

    Ford, J.R.; Maslowski, A.J.; Braby, L.A.

    2003-01-01

    Full text: A model of respiratory tissue using a perfusion culture system is being developed. We are using this system to quantify the effects of normal tissue architecture and the interaction of epithelial cells with other cell types on radiation-induced bystander effects. Tracheal tissue taken from young adult male Fischer 344 rats is imbedded in a growth factor enriched agarose matrix. The chamber is designed to allow growth medium to periodically wash the epithelial surface of the tracheal lumen while maintaining the air-interface that is necessary for the normal differentiation of the epithelium. In preliminary experiments with rat trachea we have shown that a differentiated epithelial lining can be maintained for several days. Cells can be obtained for a number of different cell culture assays for endpoints such as survival and preneoplastic transformation after irradiation

  19. Fatal complication from a balloon-expandable tracheal stent in a child: a case report.

    Science.gov (United States)

    Stotz, William H; Berkowitz, Ivor D; Hoehner, Jeff C; Tunkel, David E

    2003-01-01

    The use of airway stents in the pediatric population is uncommon, reflected in the few patient series reported in the literature. We describe a fatal complication of tracheal stent placement in an 18-month-old child with spondylothoracic dysplasia. Case report. Intensive care unit of a tertiary academic pediatric center. An 18-month-old child with spondylothoracic dysplasia who underwent tracheal stent placement for tracheomalacia. Management of an acute upper-airway hemorrhage. The patient died, despite aggressive interventions. Use of tracheal stents in pediatric patients with tracheomalacia is not without risks; tracheal erosion with severe hemoptysis is an infrequent but devastating complication of this intervention.

  20. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    Directory of Open Access Journals (Sweden)

    Thomas Berlet

    2016-01-01

    Full Text Available This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema.

  1. Cellular distribution and function of ion channels involved in transport processes in rat tracheal epithelium.

    Science.gov (United States)

    Hahn, Anne; Faulhaber, Johannes; Srisawang, Lalita; Stortz, Andreas; Salomon, Johanna J; Mall, Marcus A; Frings, Stephan; Möhrlen, Frank

    2017-06-01

    Transport of water and electrolytes in airway epithelia involves chloride-selective ion channels, which are controlled either by cytosolic Ca 2+ or by cAMP The contributions of the two pathways to chloride transport differ among vertebrate species. Because rats are becoming more important as animal model for cystic fibrosis, we have examined how Ca 2+ - dependent and cAMP- dependent Cl - secretion is organized in the rat tracheal epithelium. We examined the expression of the Ca 2+ -gated Cl - channel anoctamin 1 (ANO1), the cystic fibrosis transmembrane conductance regulator (CFTR) Cl - channel, the epithelial Na + channel ENaC, and the water channel aquaporin 5 (AQP5) in rat tracheal epithelium. The contribution of ANO1 channels to nucleotide-stimulated Cl - secretion was determined using the channel blocker Ani9 in short-circuit current recordings obtained from primary cultures of rat tracheal epithelial cells in Ussing chambers. We found that ANO1, CFTR and AQP5 proteins were expressed in nonciliated cells of the tracheal epithelium, whereas ENaC was expressed in ciliated cells. Among nonciliated cells, ANO1 occurred together with CFTR and Muc5b and, in addition, in a different cell type without CFTR and Muc5b. Bioelectrical studies with the ANO1-blocker Ani9 indicated that ANO1 mediated the secretory response to the nucleotide uridine-5'-triphosphate. Our data demonstrate that, in rat tracheal epithelium, Cl - secretion and Na + absorption are routed through different cell types, and that ANO1 channels form the molecular basis of Ca 2+ -dependent Cl - secretion in this tissue. These characteristic features of Cl - -dependent secretion reveal similarities and distinct differences to secretory processes in human airways. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  2. The Efficacy of Polydioxanone Monofilament Absorbable Suture for Tracheal Anastomosis

    OpenAIRE

    Kawahara, Katsunobu; Yamasaki, Naoya; Yamamoto, Satoshi; Nagayasu, Takeshi; Kusano, Hiroyuki; Akamine, Shinji; Takahashi, Takao; Tomita, Masao

    1994-01-01

    To evaluate the efficacy of polydioxanon absorbable suture for tracheal anastomoses, we performed an experimental study using dose. Eight adult mongrel dogs underwent sleeve resection of the mediastinal trachea. A length of ten to twelve cartilage rings was resected. An end-to-end anastomosis was performed using either interrupted or continuous running 4-0 polydioxanone (PDS) suture. There was no detectable difference bronchoscopically, microangiografically, or histologically, in tracheal ana...

  3. Association of tracheal mucus or blood and airway neutrophilia with racing performance in Thoroughbred horses in an Australian racing yard.

    Science.gov (United States)

    Salz, R O; Ahern, B J; Boston, R; Begg, L M

    2016-04-01

    To determine the variation of tracheal mucus scores, tracheal blood scores and transendoscopic tracheal wash (TW) cytology in a population of Thoroughbred (TB) racehorses and assess their association with racing performance. A total of 220 endoscopic examinations were performed and TWs obtained from 155 TB racehorses. Samples were collected 60-120 min following gallop work. Tracheal mucus score, tracheal blood score and TW cytology were analysed and their association with racing performance assessed. Of the total examinations and samples, 194 from 135 horses fitted the criteria for inclusion. The overall prevalence of visible tracheal mucus was 2.5% (5/194) and of increased tracheal mucus was 0%. The prevalence of visible tracheal blood was 8.8% (17/194) and of increased tracheal blood was 4.6% (9/194). A total of 36% (70/194) of TWs contained elevated percentages of neutrophils and of these, 96% (67/70) occurred in the absence of any visible tracheal mucus. There was no significant association between tracheal mucus score or TW cytology and subsequent racing performance. There was a statistically significant association (P = 0.004) between increased tracheal blood scores and poor racing performance. Visible tracheal blood seen after strenuous exercise in clinically normal TB racehorses was a risk factor for poor racing performance, but the presence of airway neutrophilia was not. No horses in this study were found to have increased tracheal mucus, so the association of increased tracheal mucus with racing performance could not be assessed. © 2016 Australian Veterinary Association.

  4. A bispectral index guided comparison of target-controlled versus manually-controlled infusion of propofol and remifentanil for attenuation of pressor response to laryngoscopy and tracheal intubation in non cardiac surgery

    Directory of Open Access Journals (Sweden)

    Naser Yeganeh

    2006-12-01

    Full Text Available BACKGROUND: Target-controlled infusion is a new delivery system for intravenous anesthetic agents with which the anesthetist targets a plasma or effect-site drug concentration to achieve a predetermined effect. With this system, the tedious task of calculating the amount of administered drug required to achieve the target concentration is left in charge of a microprocessor which commands the infusion device. In this prospective study we compared alterations in blood pressure and heart rate from initiation of induction of anesthesia until 3 minutes after tracheal intubation in two methods of drug infusion, target-controlled infusion (TCI and manually controlled infusion (MCI. Total anesthetic drug used until 3 minutes after intubation and level of produced hypnosis also were compared between two methods. METHODS: 40 patients were enrolled in this clinical trial study and were allocated randomly in two groups, each group consisting of 20 patients. In TCI group, patients received propofol and remifentanil with TCI pump to achieve 7 µg/ml and 4 ng/ml as plasmatic target drug levels, respectively. In MCI group, patients received propofol 2 mg/kg and remifentanil 1 µg/kg of body weight with manually controlled infusion. Both groups received succinylcholine as muscle relaxant to facilitate laryngoscopy and tracheal intubation. Bispectral index (BIS was passively recorded in two groups to compare the level of hypnosis. Blood pressure (BP and heart rate (HR were recorded at 5 different times (T-1, T0, T1, T2 and T3. Independent t-test and paired t-test were used for data analysis. RESULTS: Systolic arterial pressure (SAP was not different at T-1 between two groups but systolic hypotension was seen in MCI group more than TCI group at T0 (P<0.05. Systolic hypertension was more common in MCI group after intubation; i.e. SAP showed significant differences in T1, T2 and T3 between two groups (P<0.05. Mean arterial pressure (MAP showed significant

  5. Tracheal involvement of bronchus-associated lymphoid tissue lymphoma: a case report

    International Nuclear Information System (INIS)

    Sohn, Kyung Sik; Jeon, Kyung Neough; Kang, Duk Sik

    2002-01-01

    Primary malignant tumors of the trachea are rare, the most prevalent histologies beeing squamous cell and adenoid cystic carcinoma. A review of the literature revealed only ten cases of primary tracheal or bronchial non-Hodgkin's lymphoma. We describe a case in which tracheal involvement of bronchus-associated lymphoid tissue lymphoma, a subtype of non-Hodgkin's lymphoma, occurred

  6. Clinical application of self-expandable metallic stents in the treatment of malignant tracheal stenosis under general anesthesia

    International Nuclear Information System (INIS)

    Wang Weitao; Shi Haibin; Yang Zhengqiang; Liu Sheng; Zhou Chungao; Zhao Linbo; Xia Jinguo; Li Linsun

    2009-01-01

    Objective: To evaluate the safety and efficacy of self-expandable metallic stent placement for the treatment of malignant tracheal stenosis under general anesthesia and fluoroscopic guidance. Methods: Under general anesthesia the placement of self-expandable metallic stent was performed in 10 patients with malignant tracheal stenosis, the procedure was completed under fluoroscopic guidance in all patients. Results: Successful tracheal stenting was achieved in all 10 patients. In one patient, a Y-shaped stent was used as the tracheal carina was involved in the airway stenosis. The symptoms of dyspnea and asthma were markedly improved immediately after the implantation of stent in all patients. Conclusion: Tracheal implantation of self-expandable metallic stent under general anesthesia and fluoroscopic guidance is a safe and effective treatment for malignant tracheal stenosis, it can promptly relieve various symptoms caused by malignant tracheal stenosis and obviously improve patient's living quality, therefore,t his technique is of great value in clinical practice. (authors)

  7. An unusual salvage technique for posterior tracheal membranous laceration associated with transhiatal esophagectomy: A transcervical–transsternal approach

    Directory of Open Access Journals (Sweden)

    Seyed Ziaeddin Rasihashemi

    2017-09-01

    Full Text Available Various surgical approaches may be employed for esophageal resection. Major airway injuries due to transhiatal esophagectomy include vertical tears in the membranous trachea. Tracheal injury is an uncommon but potentially fatal complication. This article describes the technique to repair the posterior membranous tracheal tear, extended just over the carina through a transcervical–transsternal approach, thereby avoiding a second thoracotomy. Six patients with posterior membranous tracheal injury underwent this procedure. The laceration ranged from 3 cm to 5 cm in length. Four patients had received neoadjuvant chemoradiation. The management of tracheal laceration added approximately 60 minutes to the total operation time. There was no mortality related to tracheal injury. Patients were followed up for 6 months after surgery, and both posterior tracheal wall and transverse tracheotomy remained intact without stenosis. The transcervical–transsternal approach decreases the need of thoracotomy and its complications in patients with tracheal laceration in any stage, even in cases of an extended tear down to the carina.

  8. Congenital Complete Tracheal Ring in a Neonate: A Case Report

    Directory of Open Access Journals (Sweden)

    Esra ARUN ÖZER

    2017-09-01

    Full Text Available Abnormalities of the upper airway tract lead to congenital high airway obstruction and may complicate neonatal airway management in the delivery room. Congenital complete tracheal rings are a rare and unusual tracheal anomaly, usually presenting in the neonate or infant as respiratory distress. The clinical presentation can vary from almost asymptomatic patients to near-fatal airway obstruction. It may exist as an isolated entity, or in association with other congenital malformations, in particular, cardiac anomalies along with vascular rings and pulmonary slings. Other associated anomalies have also been reported, for example, chromosomal anomalies, malformation of other parts of the respiratory tract, esophagus and skeletal systems. Here, we report an extreme case of VACTERL/TACRD association presented with congenital complete tracheal ring, encephalocele, bilateral radial agenesis with absent thumbs, equinovalgus deformity on right foot, low-set ears and micrognathia.

  9. Quality assurance and quality control in fabrication of heat exchanger tubes

    International Nuclear Information System (INIS)

    Duennewald, A.

    1980-01-01

    Object of this report is the manufacture of heat exchanger tubes. A comprehensive manufacturing and test program has to be established to assure and prove and equal tube quality. This requires a functionally operating quality assurance system combined with a production exactly planned in advance. A specific continuous production line for heat exchanger tubes has been erected at the Hellenthal plant of the Mannesmannroehren-Werke. All production steps and heat treatments are generally controlled by a quality control department. Non-destructive testing of each tube produced in standard length is performed on several agregates in line using ultrasonic and/or eddy current technique. All tests are generally performed in the presence of quality inspectors or surveyors. For a lot of heat exchangers the straight tubes have to be hairpin bended. To avoid the risk of stress corrosion cracking, it is recommended to procreate defined compression stresses in the outside tube surface. Prior to releasing the tubes to shipment, the completeness of the documentation as to the manufacturing steps and inspection agreed upon is thoroughly checked. (RW)

  10. Two cases of severe tracheal stenosis due to advanced adenoid cystic carcinoma of the trachea

    Energy Technology Data Exchange (ETDEWEB)

    Yuasa, Hiroshi; Akaogi, Eiichi; Morita, Riichiro; Onizuka, Masataka; Mitsui, Kiyofumi [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Tsuji, Hirohiko

    1991-12-01

    Two cases of severe tracheal stenosis due to advanced nonresectable adenoid cystic carcinoma of the trachea were reported. Case 1 was a 38-year-old male who underwent emergency {sup 60}Co irradiation following endoscopic YAG laser irradiation. This approach was quite effective. Proton irradiation was effective against tumor recurrence. Case 2 was a 28-year-old female in whom emergency treatment for tracheal obstruction due to edema after laser therapy necessitated transient tracheal intubation. The tracheal stenosis due to recurrent tumor after {sup 60}Co irradiation was improved by insertion of an intraluminal permanent stent. (author).

  11. Large-segment tracheal resection and interannular anastomosis with a tension-release technique in the dog.

    Science.gov (United States)

    Dallman, M J; Bojrab, M J

    1982-02-01

    Tracheal resection and anastomosis were done on 7 dogs, and a modified procedure to provide optimum first-intention healing, minimum connective tissue proliferation, and optimum epithelialization was used. To test the integrity of the technique at high incision-line tensile forces, 15 to 17 tracheal rings were excised. Excessive tracheal manipulation resulted in an increased amount of lamina propria and submucosa collagenous tissue, increased size and number of blood vessels, and increased leukocytic invasion. Criteria for a successful anastomosis were minimum postoperative coughing, good mucosal apposition and epithelialization, and tracheal lumen diameters that were at least 80% of the preoperative measurement.

  12. Neutron generator tube ion source control apparatus

    International Nuclear Information System (INIS)

    Bridges, J.R.

    1982-01-01

    A pulsed neutron well logging system includes a neutron generator tube of the deuterium-tritium accelerator type and an ion source control apparatus providing extremely sharply time-defined neutron pulses. A low voltage control pulse supplied to an input by timing circuits turns a power FET on via a buffer-driver whereby a 2000 volt pulse is produced in the secondary of a pulse transformer and applied to the ion source of the tube. A rapid fall in this ion source control pulse is ensured by a quenching circuit wherein a one-shot responds to the falling edge of the control pulse and produces a 3 microsecond delay to compensate for the propagation delay. A second one-shot is triggered by the falling edge of the output of the first one-shot and gives an 8 microsecond pulse to turn on the power FET which, via an isolation transformer turns on a series-connected transistor to ground the secondary of the pulse transformer and the ion source. (author)

  13. Traumatic tracheal diverticulum corrected with resection and anastomosis during one-lung ventilation and total intravenous anesthesia in a cat.

    Science.gov (United States)

    Sayre, Rebecca S; Lepiz, Mauricio; Wall, Corey; Thieman-Mankin, Kelley; Dobbin, Jennifer

    2016-11-01

    This report describes the clinical findings and diagnostic images of a traumatic intrathoracic tracheal avulsion with a tracheal diverticulum in a cat. Furthermore, a complete description of the tracheal resection and anastomosis using one-lung ventilation (OLV) with total and partial intravenous anesthesia is made. A 3-year-old neutered male domestic shorthair cat weighing 6.8 kg was presented to the University Teaching Hospital for evaluation of increased respiratory noise 3 months following unknown trauma. Approximately 12 weeks prior to presentation, the cat had been seen by the primary care veterinarian for respiratory distress. At that time, the cat had undergone a tracheal ballooning procedure for a distal tracheal stricture diagnosed by tracheoscopy. The tracheal ballooning had provided only temporary relief. At presentation to our institution, the cat had increased respiratory effort with harsh upper airway noise auscultated during thoracic examination. The remainder of the physical examination was normal. Diagnostics included a tracheoscopy and a thoracic computed tomographic examination. The cat was diagnosed with tracheal avulsion, pseudotrachea with a tracheal diverticulum, and stenosis of the avulsed tracheal ends. Surgical correction of the tracheal stricture via a thoracotomy was performed using OLV with total and partial intravenous anesthesia. The cat recovered uneventfully and at last follow-up was active and doing well. This case report describes OLV using standard anesthesia equipment that is available at most private practices. Furthermore, this case describes the computed tomographic images of the intrathoracic tracheal avulsion and offers a positive outcome for tracheal resection and anastomosis. © Veterinary Emergency and Critical Care Society 2015.

  14. Multicentre randomised controlled trial to investigate the usefulness of continuous pneumatic regulation of tracheal cuff pressure for reducing ventilator-associated pneumonia in mechanically ventilated severe trauma patients: the AGATE study protocol.

    Science.gov (United States)

    Marjanovic, Nicolas; Frasca, Denis; Asehnoune, Karim; Paugam, Catherine; Lasocki, Sigismond; Ichai, Carole; Lefrant, Jean-Yves; Leone, Marc; Dahyot-Fizelier, Claire; Pottecher, Julien; Falcon, Dominique; Veber, Benoit; Constantin, Jean-Michel; Seguin, Sabrina; Guénézan, Jérémy; Mimoz, Olivier

    2017-08-07

    Severe trauma represents the leading cause of mortality worldwide. While 80% of deaths occur within the first 24 hours after trauma, 20% occur later and are mainly due to healthcare-associated infections, including ventilator-associated pneumonia (VAP). Preventing underinflation of the tracheal cuff is recommended to reduce microaspiration, which plays a major role in the pathogenesis of VAP. Automatic devices facilitate the regulation of tracheal cuff pressure, and their implementation has the potential to reduce VAP. The objective of this work is to determine whether continuous regulation of tracheal cuff pressure using a pneumatic device reduces the incidence of VAP compared with intermittent control in severe trauma patients. This multicentre randomised controlled and open-label trial will include patients suffering from severe trauma who are admitted within the first 24 hours, who require invasive mechanical ventilation to longer than 48 hours. Their tracheal cuff pressure will be monitored either once every 8 hours (control group) or continuously using a pneumatic device (intervention group). The primary end point is the proportion of patients that develop VAP in the intensive care unit (ICU) at day 28. The secondary end points include the proportion of patients that develop VAP in the ICU, early (≤7 days) or late (>7 days) VAP, time until the first VAP diagnosis, the number of ventilator-free days and antibiotic-free days, the length of stay in the ICU, the proportion of patients with ventilator-associated events and that die during their ICU stay. This protocol has been approved by the ethics committee of Poitiers University Hospital, and will be carried out according to the principles of the Declaration of Helsinki and the Good Clinical Practice guidelines. The results of this study will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals. Clinical Trials NCT02534974. © Article author(s) (or

  15. Effect of Fluticasone and Salmeterol on Tracheal Responsiveness to Ovalbumin and Lung Inflammation, Administrated during and after Sensitization

    Directory of Open Access Journals (Sweden)

    Zahra Gholamnezhad

    2014-01-01

    Full Text Available The effect of duration of administration of fluticasone propionate and salmeterol on tracheal responsiveness to ovalbumin and total and differential white blood cell in sensitized guinea pig was examined. Six groups of guinea pigs (n=7 were sensitized to ovalbumin. Three groups of them were subjected to inhaled fluticasone propionate and salmeterol, one group during sensitization (A, one group after that (for 18 days, B, and the other one during sensitization but with 18 days delay before measurements (C. Three other groups were treated with placebo in the same manner. The tracheal responsiveness to ovalbumin and total and differential white blood cells of three placebo groups were significantly higher than those of control group (P<0.001 for all cases. Tracheal responsiveness to ovalbumin and total and differential white blood cell in treated groups with fluticasone propionate and salmeterol were significantly decreased compared to those of placebo groups (nonsignificant to P<0.001. The improvement in all variables in treatment groups A and C were more pronounced than group B. The results showed that fluticasone propionate and salmeterol had a prevention effect on tracheal hyperresponsiveness to ovalbumin and lung inflammation which was more pronounced when administered during than after sensitization.

  16. Tracheal dimness as a sign of mediastinal pathology

    International Nuclear Information System (INIS)

    Schiavon, F.; Nardini, S.; Giannico, S.

    1987-01-01

    Some cases of mediastinal pathology in which the only pathological pattern was a dimness of the tracheal transparency are described. This sign is not described in previous report and is described as a short break in the aerial tracheogram as seen on the frontal roentgenograph. This sign is produced by an increase in the structures outside the trachea or by a decrease in the air column inside the trachea. Conventional and CT anatomic findings which account for the sign are discussed. A short review of the normal causes of tracheal dimness is presented. This sign may be useful expecially in emergency radiology, since it provides additional information to a simple routine chest roentgenograph

  17. A new retrograde transillumination technique for videolaryngoscopic tracheal intubation

    DEFF Research Database (Denmark)

    Biro, P; Fried, E; Schlaepfer, M

    2018-01-01

    This single-centre, prospective trial was designed to assess the efficacy of a new retrograde transillumination device called the 'Infrared Red Intubation System' (IRRIS) to aid videolaryngoscopic tracheal intubation. We included 40 adult patients, who were undergoing elective urological surgery......-10])), credibility (10 (8-10 [5-10])) and ease of use (10 (9-10 [8-10])). Tracheal intubation with the system lasted 26 (16-32 [6-89]) s. No alternative technique of securing the airway was necessary. The lowest SpO2 during intubation was 98 (97-99 [91-100])%. We conclude that this method of retrograde...

  18. Airway injury during emergency transcutaneous airway access: a comparison at cricothyroid and tracheal sites.

    LENUS (Irish Health Repository)

    Salah, Nazar

    2009-12-01

    Oxygenation via the cricothyroid membrane (CTM) may be required in emergencies, but inadvertent tracheal cannulation may occur. In this study, we compared airway injury between the tracheal and CTM sites using different techniques for airway access.

  19. Use of a Nitinol Wire Stent for Management of Severe Tracheal Stenosis in an Eclectus Parrot (Eclectus roratus).

    Science.gov (United States)

    Mejia-Fava, Johanna; Holmes, Shannon P; Radlinsky, MaryAnn; Johnson, Dan; Ellis, Angela E; Mayer, Jörg; Schnellbacher, Rodney; Divers, Stephen J

    2015-09-01

    A 25-year-old, female eclectus parrot (Eclectus roratus) presented for dyspnea 3 weeks after anesthesia and surgery for egg yolk coelomitis. Radiography, computed tomography, and tracheoscopy revealed multiple tracheal strictures spanning a length of 2.6 cm in the mid to distal trachea. Histopathologic examination revealed mild fibrosis, inflammation, and hyperplasia consistent with acquired tracheal strictures. Tracheal resection was not considered possible because of the length of the affected trachea. The strictures were resected endoscopically, and repeated balloon dilation under fluoroscopic guidance over the course of 10 months resulted in immediate but unsustained improvement. Computed tomography was used to measure the stenotic area. A 4 × 36-mm, custom-made, nitinol wire stent was inserted into the trachea under fluoroscopic guidance. After stent placement, intermittent episodes of mild to moderate dyspnea continued, and these responded to nebulization with a combination of saline, acetylcysteine, and dexamethasone. Multiple attempts to wean the patient off nebulization therapy and to switch to a corticosteroid-free combination were unsuccessful. The parrot eventually developed complications, was euthanatized, and necropsy was performed. Histologically, the tracheal mucosa had widespread erosion to ulceration, with accumulation of intraluminal exudate and bacteria, severe degeneration of skeletal muscle and tracheal rings, prominent fibrosis, and mild to moderate, submucosal inflammation. Clinicopathologic findings in this case suggested tracheomalacia, which has not been previously described in birds. Custom-made tracheal stents can be used for severe tracheal stenosis in birds when tracheal resection and anastomosis is not possible. Complications of tracheal stent placement in birds may include tracheitis and tracheomalacia. To our knowledge, this is the first report of tracheal stent placement in an avian species.

  20. Tracheal Atresia with Segmental Esophageal Duplication: An Unusual Anatomic Arrangement.

    Science.gov (United States)

    Gaerty, Kirsten; Thomas, Joseph T; Petersen, Scott; Tan, Edwin; Kumar, Sailesh; Gardener, Glenn; Armes, Jane

    2016-01-01

    An unusual anatomic configuration of segmental tracheal agenesis/atresia with esophageal duplication on autopsy in a fetus that demised in utero at 29 weeks is reported. The mother was scanned initially for a cardiac anomaly at 20 weeks and on follow-up scan at 27 weeks had polyhydramnios and underwent amnioreduction. The final autopsy diagnosis was vertebral, ano-rectal, cardiac, tracheoesophageal, renal, and limb malformations (VACTERL). We discuss the autopsy findings along with the embryological mechanisms and compare the configuration with Floyd's classification for tracheal agenesis. The difficulties in prenatal diagnosis are discussed.

  1. Tracheal adenoid cystic carcinoma masquerading asthma: A case report

    Directory of Open Access Journals (Sweden)

    Kurul Cuneyt

    2004-10-01

    Full Text Available Abstract Background Tracheal tumors are often misdiagnosed as asthma and are treated with inhaled steroids and bronchodilators without resolution. Case Presentation Here, a patient with tracheal adenoid cystic carcinoma who had been previously diagnosed with difficult asthma was reported. The possibility of the presence of localized airway obstruction was raised when the flow-volume curve suggesting fixed airway obstruction, was obtained. Conclusion The presenting case report emphasizes the fact that not all wheezes are asthma. It is critical to bear in mind that if a patient does not respond to appropriate anti-asthma therapy, localized obstructions should be ruled out before establishing the diagnosis of asthma.

  2. Is intrathoracic tracheal collapsibility correlated to clinical phenotypes and sex in patients with COPD?

    Directory of Open Access Journals (Sweden)

    Camiciottoli G

    2015-04-01

    Full Text Available Gianna Camiciottoli,1 Stefano Diciotti,2 Francesca Bigazzi,1 Simone Lombardo,3 Maurizio Bartolucci,4 Matteo Paoletti,1 Mario Mascalchi,3 Massimo Pistolesi1 1Section of Respiratory Medicine, Department of Clinical and Experimental Medicine, University of Florence, Florence, Italy; 2Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi,” University of Bologna, Cesena, Italy; 3Radiodiagnostic Section, Department of Clinical and Experimental Biomedical Sciences, University of Florence, Florence, Italy; 4Department of Diagnostic Imaging, Careggi University Hospital, Florence, Italy Abstract: A substantial proportion of patients with chronic obstructive pulmonary disease (COPD develops various degree of intrathoracic tracheal collapsibility. We studied whether the magnitude of intrathoracic tracheal collapsibility could be different across clinical phenotypes and sex in COPD. Intrathoracic tracheal collapsibility measured at paired inspiratory–expiratory low dose computed tomography (CT and its correlation with clinical, functional, and CT-densitometric data were investigated in 69 patients with COPD according to their predominant conductive airway or emphysema phenotypes and according to sex. Intrathoracic tracheal collapsibility was higher in patients with predominant conductive airway disease (n=28 and in females (n=27. Women with a predominant conductive airway phenotype (n=10 showed a significantly greater degree of collapsibility than women with predominant emphysema (28.9%±4% versus 11.6%±2%; P<0.001. Intrathoracic tracheal collapsibility was directly correlated with inspiratory–expiratory volume variation at CT and with forced expiratory volume (1 second, and inversely correlated with reduced CT lung density and functional residual capacity. Intrathoracic tracheal collapsibility was not correlated with cough and wheezing; however, intrathoracic tracheal collapsibility and clinical phenotypes of COPD

  3. Mathematical modeling and control of plate fin and tube heat exchangers

    International Nuclear Information System (INIS)

    Taler, Dawid

    2015-01-01

    Highlights: • A method for numerical modeling of plate fin and tube heat exchangers was proposed. • A numerical model of an automobile radiator was developed. • Numerical models of the radiator were compared with an exact analytical model. • A model-based control system of water outlet temperature was built and tested. • A digital proportional–integral–derivative controller of heat exchanger was tested. - Abstract: The aim of the study is to develop a new method for numerical modeling of tubular cross-flow heat exchangers. Using the method proposed in the paper, a numerical model of a car radiator was developed and implemented in a digital control system of the radiator. To evaluate the accuracy of the numerical method proposed in the paper, the numerical model of the car radiator was compared with an analytic model. The proposed method based on a finite volume method and integral averaging of gas temperature across a tube row is appropriate for modeling of plate fin and tube heat exchangers, especially for exchangers in which substantial gas temperature differences in one tube row occur. The target of control is to regulate the number of fan revolutions per minute so that the water temperature at the heat exchanger outlet is equal to a set value. Two control techniques were developed. The first is based on the numerical model of the heat exchanger developed in the paper while the second is a digital proportional–integral–derivative control. The first control method is very stable. The digital proportional–integral–derivative controller becomes unstable when the water volume flow rate varies considerably. The developed techniques were implemented in digital control system of the water exit temperature in a plate fin and tube heat exchanger. The measured exit temperature of the water was very close to the set value of the temperature if the first method was used. The experiments show that the proportional–integral–derivative controller

  4. Thyroidectomy improves tracheal anatomy and airflow in patients with nodular goiter

    DEFF Research Database (Denmark)

    Sørensen, Jesper Roed; Lauridsen, Jeppe Killerich; Døssing, Helle

    . Effect sizes (ES) were calculated as mean change divided by standard deviation at baseline. ES of 0.2-0.5 were defined as small, 0.5-0.8 as moderate, and values >0.8 as large. Results: Sixty-five patients completed all examinations. Median goiter volume was 58 mL (range, 14-642 mL) before surgery...... resonance images (MRI) of the neck and respiratory flow-volume curves, including both in- and expiration, were performed prior to and six months following surgery. The evaluated tracheal dimensions included the smallest cross-sectional area of the trachea (SCAT), tracheal narrowing, and tracheal deviation...... with surgical removal of median 46 mL (range, 5-642 mL) (pdeviation were diminished by median 26% (ES=0.67), and 33% (ES=0.73), respectively, while SCAT increased by 17% (ES=0.61). Correspondingly, each 10% decrease in goiter volume resulted...

  5. Development of a 3D bellows tracheal graft: mechanical behavior analysis, fabrication and an in vivo feasibility study

    International Nuclear Information System (INIS)

    Park, Jeong Hun; Jung, Jin Woo; Lee, Jung-Seob; Cho, Dong-Woo; Kang, Hyun-Wook; Joo, Young Hoon

    2012-01-01

    Artificial tracheal grafts should have not only enough compressive strength to maintain an open tracheal lumen, but also sufficient flexibility for stable mechanical behavior, similar to the native trachea at the implant site. In this study, we developed a new 3D artificial tracheal graft using a bellows design for considering its mechanical behavior. To investigate the mechanical behavior of the bellows structure, finite element method (FEM) analysis in terms of longitudinal tension/compression, bending and radial compression was conducted. The bellows structure was then compared with the cylinder structure generally used for artificial tracheal grafts. The FEM analysis showed that the bellows had outstanding flexibility in longitudinal tension/compression and bending. Moreover, the bellows kept the lumen open without severe luminal deformation in comparison with the cylinder structure. A three-dimensional artificial tracheal graft with a bellows design was fabricated using indirect solid freeform fabrication technology, and the actual mechanical test was conducted to investigate the actual mechanical behavior of the bellows graft. The fabricated bellows graft was then applied to segmental tracheal reconstruction in a rabbit model to assess its applicability. The bellows graft was completely incorporated into newly regenerated connective tissue and no obstruction at the implanted site was observed for up to 8 weeks after implantation. The data suggested that the developed bellows tracheal graft could be a promising alternative for tracheal reconstruction. (paper)

  6. The relationships between tracheal index and lung volume parameters in mild-to-moderate COPD

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Jung Seop, E-mail: ejs00@hanmail.net [Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Lee, Geewon, E-mail: rabkingdom@naver.com [Department of Radiology, Pusan National University Hospital, 179 Gudeok-ro, Seo-gu, Busan 602-739 (Korea, Republic of); Lee, Ho Yun, E-mail: hoyunlee96@gmail.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Oh, Jin Young, E-mail: indr71@hanmail.net [Division of Pulmonology, Department of Internal Medicine, Dongguk University Ilsan Medical Center, 814 Siksa-dong, Ilsandong-gu, Goyang-si, Gyeonggi-do 410-773 (Korea, Republic of); Woo, Sook-young, E-mail: sookyoung12.woo@samsung.com [Biostatistics Team, Samsung Biomedical Research Institute, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Jeon, Kyeongman, E-mail: kjeon@skku.edu [Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Um, Sang-Won, E-mail: sangwonum@skku.edu [Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Koh, Won-Jung, E-mail: wjkoh@skku.edu [Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Suh, Gee Young, E-mail: suhgy@skku.edu [Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); and others

    2013-12-01

    Background: Although elongated morphological changes in the trachea are known to be related to lung function in chronic obstructive pulmonary disease (COPD), whether the tracheal morphological changes are associated with airflow limitations or overinflation of the lung in the early stages of COPD has not yet been determined. Thus, our aim was to investigate the association of tracheal index (TI) with lung function parameters, including lung volume parameters, in COPD patients with mild-to-moderate airflow limitations. Materials and methods: A retrospective study was conducted in 193 COPD patients with GOLD grades 1–2 (post-bronchodilator forced expiratory volume in 1 s [FEV{sub 1}] ≥ 50% predicted with FEV{sub 1}/forced vital capacity ratio ≤ 70%; age range, 40–81) and 193 age- and gender-matched subjects with normal lung function as a control group (age range, 40–82). Two independent observers measured TI at three anatomical levels on chest radiographs and CT scans. Results: Compared with the control group, TI was reduced significantly and “saber-sheath trachea” was observed more frequently in COPD patients. Patients with GOLD grade 2 disease had a lower TI than those with GOLD grade 1. TI had apparent inverse correlations with total lung capacity, functional residual capacity, and residual volume, regardless of the anatomical level of the trachea. Even after adjustments for covariates, this association persisted. Conclusions: TI is reduced even in mild-to-moderate COPD patients, and TI measured on chest CT shows significant inverse relationships with all lung volume parameters assessed, suggesting that tracheal morphology may change during the early stages of COPD.

  7. The relationships between tracheal index and lung volume parameters in mild-to-moderate COPD

    International Nuclear Information System (INIS)

    Eom, Jung Seop; Lee, Geewon; Lee, Ho Yun; Oh, Jin Young; Woo, Sook-young; Jeon, Kyeongman; Um, Sang-Won; Koh, Won-Jung; Suh, Gee Young

    2013-01-01

    Background: Although elongated morphological changes in the trachea are known to be related to lung function in chronic obstructive pulmonary disease (COPD), whether the tracheal morphological changes are associated with airflow limitations or overinflation of the lung in the early stages of COPD has not yet been determined. Thus, our aim was to investigate the association of tracheal index (TI) with lung function parameters, including lung volume parameters, in COPD patients with mild-to-moderate airflow limitations. Materials and methods: A retrospective study was conducted in 193 COPD patients with GOLD grades 1–2 (post-bronchodilator forced expiratory volume in 1 s [FEV 1 ] ≥ 50% predicted with FEV 1 /forced vital capacity ratio ≤ 70%; age range, 40–81) and 193 age- and gender-matched subjects with normal lung function as a control group (age range, 40–82). Two independent observers measured TI at three anatomical levels on chest radiographs and CT scans. Results: Compared with the control group, TI was reduced significantly and “saber-sheath trachea” was observed more frequently in COPD patients. Patients with GOLD grade 2 disease had a lower TI than those with GOLD grade 1. TI had apparent inverse correlations with total lung capacity, functional residual capacity, and residual volume, regardless of the anatomical level of the trachea. Even after adjustments for covariates, this association persisted. Conclusions: TI is reduced even in mild-to-moderate COPD patients, and TI measured on chest CT shows significant inverse relationships with all lung volume parameters assessed, suggesting that tracheal morphology may change during the early stages of COPD

  8. Sporophytic control of pollen tube growth and guidance in maize

    Science.gov (United States)

    Lausser, Andreas; Kliwer, Irina; Srilunchang, Kanok-orn; Dresselhaus, Thomas

    2010-01-01

    Pollen tube germination, growth, and guidance (progamic phase) culminating in sperm discharge is a multi-stage process including complex interactions between the male gametophyte as well as sporophytic tissues and the female gametophyte (embryo sac), respectively. Inter- and intra-specific crossing barriers in maize and Tripsacum have been studied and a precise description of progamic pollen tube development in maize is reported here. It was found that pollen germination and initial tube growth are rather unspecific, but an early, first crossing barrier was detected before arrival at the transmitting tract. Pollination of maize silks with Tripsacum pollen and incompatible pollination of Ga1s/Ga1s-maize silks with ga1-maize pollen revealed another two incompatibility barriers, namely transmitting tract mistargeting and insufficient growth support. Attraction and growth support by the transmitting tract seem to play key roles for progamic pollen tube growth. After leaving transmitting tracts, pollen tubes have to navigate across the ovule in the ovular cavity. Pollination of an embryo sac-less maize RNAi-line allowed the role of the female gametophyte for pollen tube guidance to be determined in maize. It was found that female gametophyte controlled guidance is restricted to a small region around the micropyle, approximately 50–100 μm in diameter. This area is comparable to the area of influence of previously described ZmEA1-based short-range female gametophyte signalling. In conclusion, the progamic phase is almost completely under sporophytic control in maize. PMID:19926683

  9. Treatment of Benign Tracheal Stenosis Utilizing Self-Expanding Nitinol Stents

    International Nuclear Information System (INIS)

    Sesterhenn, Andreas M.; Wagner, Hans-Joachim; Alfke, Heiko; Werner, Jochen A.; Lippert, Burkard M.

    2004-01-01

    We assessed the results of self-expanding metallic stent insertion into benign proximal tracheal stenosis in patients not appropriate or unfit for surgical repair. Proximal benign tracheal stenoses had occurred in 11 patients (7 men, 4 women, mean age 68.8 years) after long-time intubation (n = 6), tracheostomy (n = 4), or chondropathia (n = 1). Fourteen self-expanding nitinol stents were placed in the patients under general anesthesia with endoscopical and fluoroscopical guidance. Stent insertion was successful in all cases and led to immediate relief of the morphological and functional airway obstruction. No immediate complications were noted. During the mean follow-up period of 67.5 weeks we observed one recurrent dyspnea 3 months after implantation and granuloma formation at the stent insertion site in another patient. Both complications were successfully treated with additional stent insertion in one case and laser resection of granulomas in the other. Self-expanding nitinol stents should be considered for the treatment of benign proximal tracheal obstruction in selected patients for whom surgical repair is contraindicated

  10. Association between pathogens from tracheal aspirate and oral biofilm of patients on mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Luana Carneiro Diniz SOUZA

    2017-06-01

    Full Text Available Abstract The aim of this study was to detect possible associations between respiratory pathogens from tracheal aspirate and oral biofilm samples in intubated patients in an intensive care unit (ICU, and to identify the most common respiratory pathogens in oral biofilm, particularly in patients that developed ventilator-associated pneumonia (VAP. Two oral biofilm samples were collected from the tongue of intubated patients (at admission and after 48 hours and analyzed by culture with the Antibiotic Sensitivity Test. The results from the tongue biofilm samples were compared with the tracheal secretions samples. A total of 59.37% of patients exhibited the same species of pathogens in their tracheal aspirate and oral biofilm, of which 8 (42.1% developed VAP, 10 (52.63% did not develop pneumonia and one (5.26% had aspiration pneumonia. There was a statistically significant association between presence of microorganisms in the tracheal and mouth samples for the following pathogens: Klebsiella pneumoniae, Candida albicans, Pseudomonas aeruginosa, Enterobacter gergoviae, Streptococcus spp and Serratia marcescens (p < 0.05. Pathogens that are present in tracheal aspirates of intubated patients can be detected in their oral cavity, especially in those who developed VAP or aspiration pneumonia. Thus, the results indicate that an improved oral care in these patients could decrease ICU pneumonia rates.

  11. Difficult Tracheal Intubation in Obese Gastric Bypass patients

    DEFF Research Database (Denmark)

    Dohrn, Niclas; Sommer, Thorbjørn; Bisgaard, J.

    2016-01-01

    Endotracheal intubation is commonly perceived to be more difficult in obese patients than in lean patients. Primarily, we investigated the association between difficult tracheal intubation (DTI) and obesity, and secondarily, the association between DTI and validated scoring systems used to assess...... the airways, the association between DTI and quantities of anesthetics used to induce general anesthesia, and the association between DTI and difficulties with venous and arterial cannulation. This is a monocentric prospective observational clinical study of a consecutive series of 539 obese patients...... was 3.5 % and the patients with DTI were more frequently males, had higher CLC, higher American Society of Anesthesiologists physical status classification (ASA), and noticeably, a lower BMI compared to the patients with easy tracheal intubation. After adjustment with multivariable analyses body mass...

  12. Mucus glycoprotein secretion by tracheal explants: effects of pollutants

    International Nuclear Information System (INIS)

    Last, J.A.; Kaizu, T.

    1980-01-01

    Tracheal slices incubated with radioactive precursors in tissue culture medium secrete labeled mucus glycoproteins into the culture medium. We have used an in vivtro approach, a combined method utilizing exposure to pneumotoxins in vivo coupled with quantitation of mucus secretion rates in vitro, to study the effects of inhaled pollutants on mucus biosynthesis by rat airways. In addition, we have purified the mucus glycoproteins secreted by rat tracheal explants in order to determine putative structural changes that might by the basis for the observed augmented secretion rates after exposure of rats to H2SO4 aerosols in combination with high ambient levels of ozone. After digestion with papain, mucus glycoproteins secreted by tracheal explants may be separated into five fractions by ion-exchange chromatography, with recovery in high yield, on columns of DEAE-cellulose. Each of these five fractions, one neutral and four acidic, migrates as a single unique spot upon cellulose acetate electrophoresis at pH values of 8.6 and 1.2. The neutral fraction, which is labeled with [3H] glucosamine, does not contain radioactivity when Na2 35SO4 is used as the precursor. Acidic fractions I to IV are all labeled with either 3H-glucosamine or Na2 35SO4 as precursor. Acidic fraction II contains sialic acid as the terminal sugar on its oligosaccharide side chains, based upon its chromatographic behavior on columns of wheat-germ agglutinin-Agarose. Treatment of this fraction with neuraminidase shifts its elution position in the gradient to a lower salt concentration, coincident with acidic fraction I. After removal of terminal sialic acid residues with either neuraminidase or low pH treatment, the resultant terminal sugar on the oligosaccharide side chains is fucose. These results are identical with those observed with mucus glycoproteins secreted by cultured human tracheal explants and purified by these same techniques

  13. Treatment of Benign Tracheal Stenosis Using Endoluminal Spray Cryotherapy.

    Science.gov (United States)

    Bhora, Faiz Y; Ayub, Adil; Forleiter, Craig M; Huang, Chyun-Yin; Alshehri, Khalid; Rehmani, Sadiq; Al-Ayoubi, Adnan M; Raad, Wissam; Lebovics, Robert S

    2016-11-01

    Tracheal stenosis is a debilitating disorder with heterogeneity in terms of disease characteristics and management. Repeated recurrences substantially alter patients' quality of life. There is limited evidence for the use of spray cryotherapy (SCT) in the management of benign airway disease. To report our early results for the use of SCT in patients with benign tracheal stenosis. Data were extracted from the medical records of a consecutive series of patients with benign airway stenosis secondary to granulomatosis with polyangiitis (GPA) (n = 13), prior tracheotomy or tracheal intubation (n = 8), and idiopathic strictures (n = 5) treated from September 1, 2013, to September 30, 2015, at a tertiary care hospital. Airway narrowing was quantified on a standard quartile grading scale. Response to treatment was assessed by improvement in airway caliber and the time interval for reintervention. Delivery of 4 5-second SCT cycles and 2 balloon dilatations. Twenty-six patients (median [range] age, 53 [16-83] years; 20 [77%] female) underwent 48 SCT sessions. Spray cryotherapy was successfully used without any substantial intraoperative or postoperative complications in all patients. In a median (range) follow-up of 11 (1-26) months, all patients had improvement in symptoms. Before the institution of SCT, 23 patients (88%) had grade III or IV stenosis. At the last evaluation after induction of SCT, 4 (15%) had grade III or IV stenosis, with a mean (SD) change of 1.39 (0.51) (P benign tracheal stenosis. Although efficacy evidence is limited for SCT, it may be useful for patients who have experienced treatment failure with conventional modalities. Further analysis of this cohort will determine the physiologic durability of the reported short-term changes. Additional trials are warranted for further evaluation of this modality.

  14. Prevalence of streptococcus group B in tracheal tube secretions of neonates with respiratory distress: a brief report

    Directory of Open Access Journals (Sweden)

    Khosravi N

    2013-02-01

    Full Text Available Background: Infection with group B streptococcus (GBS can present with respiratory distress, Pneumonia, meningitis and Osteomyelitis in neonates. The aim of this study was to determine the prevalence of GBS colonization in trachea of intubated neonates.Methods: This observational analytic study was performed upon 33 intubated neonates due to respiratory distress in neonatal intensive care unit (NICU Rasoul Hospital in Tehran, Iran during 2010-2012. Tracheal secretions cultured upon TODD-HEWITT BROTH and sheep blood agar 5%., chi-square test was used for compare the qualitative variables. P<0.05 was considered meaningful.Results: Three cases had positive streptococcal culture (9.1% and four cases had posi-tive culture for non-streptococcal organisms. no meaningful relation observed between positive GBS culture and neonatal gender, kind of delivery, PROM.Conclusion: Prevalence of GBS positive results (9% in present study is very close to GBS colonization in pregnant women; although the higher colonization rate of pregnant women are expected.

  15. The biofilm-controlling functions of rechargeable antimicrobial N-halamine dental unit waterline tubing.

    Science.gov (United States)

    Porteous, Nuala; Schoolfield, John; Luo, Jie; Sun, Yuyu

    2011-01-01

    A study was conducted to test the biofilm-controlling functions of N-halamine tubing over an eight-month period. A laboratory system, simulating a teaching dental clinic, was used to test rechargeable N-halamine tubing (T) compared to an untreated control (C) using the unit manufacturer's tubing. For the long-term study, a recharged tubing (RC) treated with bleach was used to compare with the test (T) and the control (C) tubing. Source tap water was cycled through the lines at 1.4 mL/minute, five minutes on and 25 minutes off, eight hours/day, five days/week. Every three weeks, samples of effluent, recovered adherent bacteria from inside tubing surfaces, and SEM images were examined for bacterial and biofilm growth. After sampling, a recharging solution of chlorine bleach (1 : 10 dilution) was run through T and RC lines, left overnight, and rinsed out the next morning. One-way ANOVAs and Spearman correlations were performed to detect significant differences for T, RC, and C, and determine significance with time period and source water, respectively. Mean log CFU/mL for C effluent > T (p = 0.028), and C tubing > T (p = 0.035). Spearman correlations were significant between effluent and source water level for T (rho = 0.817), and T tubing (0.750); between RC tubing and source water level (rho = 0.836), and time (rho = 0.745); and between C and time (rho = 0.873). SEM imaging confirmed the presence of biofilm inside RC and C, but not inside T. N-halamine tubing completely inhibited biofilm formation without negatively affecting the physical properties of the effluent water. Further research on N-halamine tubing using a pure water source is recommended, as T effluent bacterial levels reflected the source tap water quality and proliferation of planktonic bacteria with no biofilm activity.

  16. Myosin light chain kinase phosphorylation in tracheal smooth muscle

    International Nuclear Information System (INIS)

    Stull, J.T.; Hsu, L.C.; Tansey, M.G.; Kamm, K.E.

    1990-01-01

    Purified myosin light chain kinase from smooth muscle is phosphorylated by cyclic AMP-dependent protein kinase, protein kinase C, and the multifunctional calmodulin-dependent protein kinase II. Because phosphorylation in a specific site (site A) by any one of these kinases desensitizes myosin light chain kinase to activation by Ca2+/calmodulin, kinase phosphorylation could play an important role in regulating smooth muscle contractility. This possibility was investigated in 32 P-labeled bovine tracheal smooth muscle. Treatment of tissues with carbachol, KCl, isoproterenol, or phorbol 12,13-dibutyrate increased the extent of kinase phosphorylation. Six primary phosphopeptides (A-F) of myosin light chain kinase were identified. Site A was phosphorylated to an appreciable extent only with carbachol or KCl, agents which contract tracheal smooth muscle. The extent of site A phosphorylation correlated to increases in the concentration of Ca2+/calmodulin required for activation. These results show that cyclic AMP-dependent protein kinase and protein kinase C do not affect smooth muscle contractility by phosphorylating site A in myosin light chain kinase. It is proposed that phosphorylation of myosin light chain kinase in site A in contracting tracheal smooth muscle may play a role in the reported desensitization of contractile elements to activation by Ca2+

  17. Rechargeable biofilm-controlling tubing materials for use in dental unit water lines.

    Science.gov (United States)

    Luo, Jie; Porteous, Nuala; Sun, Yuyu

    2011-08-01

    A simple and practical surface grafting approach was developed to introduce rechargeable N-halamine-based antimicrobial functionality onto the inner surfaces of continuous small-bore polyurethane (PU) dental unit waterline (DUWL) tubing. In this approach, tetrahydrofuran (THF) solution of a free-radical initiator, dicumyl peroxide (DCP), flowed through the PU tubing (inner diameter of 1/16 in., or 1.6 mm) to diffuse DCP into the tubing's inner walls, which was used as initiator in the subsequent grafting polymerization of methacrylamide (MAA) onto the tubing. Upon chlorine bleach treatment, the amide groups of the grafted MAA side chains were transformed into acyclic N-halamines. The reactions were confirmed with attenuated total reflectance infrared (ATR) spectra and iodometric titration. The mechanical properties of the tubing were not significantly affected by the grafting reactions. The biofilm-controlling function of the new N-halamine-based PU tubing was evaluated with Pseudomonas aeruginosa (P. aeruginosa), one of the most isolated water bacteria from DUWLs, in a continuous bacterial flow model. Bacteria culturing and SEM studies showed that the inner surfaces of the new N-halamine-based PU tubing completely prevented bacterial biofilm formation for at least three to four weeks. After that, bacteria began to colonize the tubing surface. However, the lost function was fully regenerated by exposing the tubing inner surfaces to diluted chlorine bleach. The recharging process could be repeated periodically to further extend the biofilm-controlling duration for long-term applications.

  18. Airflow in Tracheobronchial Tree of Subjects with Tracheal Bronchus Simulated Using CT Image Based Models and CFD Method.

    Science.gov (United States)

    Qi, Shouliang; Zhang, Baihua; Yue, Yong; Shen, Jing; Teng, Yueyang; Qian, Wei; Wu, Jianlin

    2018-03-01

    Tracheal Bronchus (TB) is a rare congenital anomaly characterized by the presence of an abnormal bronchus originating from the trachea or main bronchi and directed toward the upper lobe. The airflow pattern in tracheobronchial trees of TB subjects is critical, but has not been systemically studied. This study proposes to simulate the airflow using CT image based models and the computational fluid dynamics (CFD) method. Six TB subjects and three health controls (HC) are included. After the geometric model of tracheobronchial tree is extracted from CT images, the spatial distribution of velocity, wall pressure, wall shear stress (WSS) is obtained through CFD simulation, and the lobar distribution of air, flow pattern and global pressure drop are investigated. Compared with HC subjects, the main bronchus angle of TB subjects and the variation of volume are large, while the cross-sectional growth rate is small. High airflow velocity, wall pressure, and WSS are observed locally at the tracheal bronchus, but the global patterns of these measures are still similar to those of HC. The ratio of airflow into the tracheal bronchus accounts for 6.6-15.6% of the inhaled airflow, decreasing the ratio to the right upper lobe from 15.7-21.4% (HC) to 4.9-13.6%. The air into tracheal bronchus originates from the right dorsal near-wall region of the trachea. Tracheal bronchus does not change the global pressure drop which is dependent on multiple variables. Though the tracheobronchial trees of TB subjects present individualized features, several commonalities on the structural and airflow characteristics can be revealed. The observed local alternations might provide new insight into the reason of recurrent local infections, cough and acute respiratory distress related to TB.

  19. High frequency components of tracheal sound are emphasized during prolonged flow limitation

    International Nuclear Information System (INIS)

    Tenhunen, M; Huupponen, E; Saastamoinen, A; Kulkas, A; Himanen, S-L; Rauhala, E

    2009-01-01

    A nasal pressure transducer, which is used to study nocturnal airflow, also provides information about the inspiratory flow waveform. A round flow shape is presented during normal breathing. A flattened, non-round shape is found during hypopneas and it can also appear in prolonged episodes. The significance of this prolonged flow limitation is still not established. A tracheal sound spectrum has been analyzed further in order to achieve additional information about breathing during sleep. Increased sound frequencies over 500 Hz have been connected to obstruction of the upper airway. The aim of the present study was to examine the tracheal sound signal content of prolonged flow limitation and to find out whether prolonged flow limitation would consist of abundant high frequency activity. Sleep recordings of 36 consecutive patients were examined. The tracheal sound spectral analysis was performed on 10 min episodes of prolonged flow limitation, normal breathing and periodic apnea-hypopnea breathing. The highest total spectral amplitude, implicating loudest sounds, occurred during flow-limited breathing which also presented loudest sounds in all frequency bands above 100 Hz. In addition, the tracheal sound signal during flow-limited breathing constituted proportionally more high frequency activities compared to normal breathing and even periodic apnea-hypopnea breathing

  20. Comparison of Ambu® AuraGain™ laryngeal mask and air-Q™ intubating laryngeal airway for blind tracheal intubation in adults: A randomized controlled trial

    OpenAIRE

    Sameer Sethi; Souvik Maitra; Vikas Saini; Tanvir Samara

    2017-01-01

    Background: This study has been designed to compare the performance of Ambu® AuraGain™ laryngeal mask with the air-Q™ as a conduit for blind tracheal intubation in adult patients. Methods: In this prospective randomized controlled trial blind endotracheal intubation success rates were compared between Ambu® AuraGain™ and air-Q™ intubating laryngeal airway in 90 adult patients. Patients were randomized in two equal groups: Group Ambu® AuraGain™ (n = 45) and Group air-Q™ (n = 45). Results...

  1. Tracheal obstruction caused by an expandable metallic stent: a case of successful removal of the stent.

    Science.gov (United States)

    Okuyama, Hiroomi; Kubota, Akio; Kawahara, Hisayoshi; Oue, Takaharu; Nose, Satoko; Ihara, Toshiyuki

    2005-07-01

    We report a case of tracheal obstruction caused by an expandable metallic stent. A 3-month-old girl with severe tracheomalacia had a placement of a Palmaz stent. At 3 years of age, she developed progressive dyspnea. The CT scan showed tracheal obstruction caused by granulation tissue over the stent. At operation, the stent was found to have penetrated the posterior tracheal wall. Under partial cardiopulmonary bypass, the stent was removed along with the membranous wall of the trachea, and the trachea was reconstructed using slide tracheoplasty. Tracheal obstruction is one of the serious complications caused by an expandable metallic stent. Direct open approach to the trachea under cardiopulmonary bypass is thought to be a safe way to manage this problem.

  2. Tracheal epithelial-myoepithelial carcinoma associated with sarcoid-like reaction: A case report

    Science.gov (United States)

    Dong, Huawei; Tatsuno, Brent K.; Betancourt, Jaime; Oh, Scott S.

    2014-01-01

    Epithelial-myoepithelial carcinomas are rare tumors that primarily originate in the salivary glands but have also been found in the tracheobronchial tree. We report the first case of epithelial-myoepithelial carcinoma associated with sarcoidosis. A 61 year old Hispanic man presented with altered mental status and hypercalcemia. Imaging revealed diffuse intra-thoracic and intra-abdominal lymphadenopathy. A diagnostic bronchoscopy was performed where an incidental tracheal nodule was discovered and biopsied. Pathology was consistent with epithelial-myoepithelial carcinoma. Lymph node biopsy demonstrated non-caseating granulomas consistent with sarcoidosis. Patient underwent tracheal resection of the primary tumor with primary tracheal reconstruction. Hypercalcemia subsequently normalized with clinical improvement. Repeat CT imaging demonstrated complete resolution of lymphadenopathy. Our findings are suggestive of a possible paraneoplastic sarcoid-like reaction to the epithelial-myoepithelial carcinoma with associated lymphadenopathy and symptomatic hypercalcemia. PMID:26029574

  3. Endobronchial angiofibroma in the aberrant tracheal bronchus presenting as spontaneous pneumomediastinum.

    Science.gov (United States)

    Kim, Kyung Soo; Moon, Young Kyu; Jeon, Hyun Woo; Park, Chan Beom; Ahn, Myeong Im; Lee, Kyo Young; Park, Jae Kil

    2015-07-22

    Spontaneous pneumomediastinum is a self-limiting benign disease but abnormal bronchial lesions can be rarely found incidentally, and in selected cases will require surgical resection. A 38-year-old man presented with a spontaneous pneumomediastinum. Chest computed tomography revealed an incidental linear endobronchial tumour in the aberrant tracheal bronchus. The tumour was removed surgically and diagnosed with a rare benign tumour of endobronchial angiofibroma. We report a rare case of endobronchial angiofibroma in the aberrant tracheal bronchus which was detected during the evaluation of a spontaneous pneumomediastinum.

  4. Fracture of an endoluminal nitinol stent used in the treatment of tracheal collapse in a dog.

    Science.gov (United States)

    Mittleman, Elise; Weisse, Chick; Mehler, Stephen J; Lee, Justine A

    2004-10-15

    A 5-year-old castrated male Pomeranian was evaluated because of severe dyspnea and coughing, and a diagnosis of complete, static collapse of the trachea at the thoracic inlet was made. After failure to improve with medical management alone, an endoluminal tracheal stent was placed, which resulted in resolution of signs. Ten weeks after stent placement, the dog underwent tracheal resection and anastomosis because the stent had fractured at the level of the thoracic inlet. One year after surgery, the dog was doing well and required treatment with hydrocodone infrequently. Compared with other surgical treatment options, placement of an endoluminal tracheal stent is a relatively noninvasive intervention that can provide effective relief from the clinical signs associated with tracheal collapse in dogs. Implantation of endoluminal tracheal stents may be associated with complications; therefore, the procedure may best be regarded as a salvage procedure for dogs with end-stage disease that are refractory to appropriate medical management, have extensive collapse of the intrathoracic portion of the trachea, or are poor candidates for surgery.

  5. Trypsin as enhancement in cyclical tracheal decellularization: Morphological and biophysical characterization

    Energy Technology Data Exchange (ETDEWEB)

    Giraldo-Gomez, D.M., E-mail: davidmauro2008@gmail.com [Posgrado en Ciencia e Ingeniería de Materiales, Universidad Nacional Autónoma de México (UNAM), Unidad de Posgrado Edificio “C” 1er Piso, Circuito de Posgrados, Avenida Universidad 3000, Ciudad Universitaria, Coyoacán, C.P. 04510, México D. F., México (Mexico); Instituto de Investigaciones en Materiales, Universidad Nacional Autónoma de México (UNAM), Circuito Exterior, Avenida Universidad 3000, Ciudad Universitaria, Coyoacán, C.P. 04510, México D.F., México (Mexico); Leon-Mancilla, B. [Departamento de Cirugía, Facultad de Medicina, Universidad Nacional Autónoma de México (UNAM), Edificio “D” Planta Baja, Circuito Interior, Avenida Universidad 3000, Ciudad Universitaria, Coyoacán, C.P. 04510, México D.F., México (Mexico); Del Prado-Audelo, M.L. [Instituto de Investigaciones en Materiales, Universidad Nacional Autónoma de México (UNAM), Circuito Exterior, Avenida Universidad 3000, Ciudad Universitaria, Coyoacán, C.P. 04510, México D.F., México (Mexico); and others

    2016-02-01

    There are different types of tracheal disorders (e.g. cancer, stenosis and fractures). These can cause respiratory failure and lead to death of patients. Several attempts have been made for trachea replacement in order to restore the airway, including anastomosis and implants made from synthetic or natural materials. Tracheal allotransplantation has shown high rejection rates, and decellularization has emerged as a possible solution. Decellularization involves the removal of antigens from cells in the organ or tissue, leaving a matrix that can be used as 3D cell-scaffold. Although this process has been used for tracheal replacement, it usually takes at least two months and time is critical for patients with tracheal disorders. Therefore, there is necessary to develop a tracheal replacement process, which is not only effective, but also quick to prepare. The aim of this research was to develop a faster trachea decellularization protocol using Trypsin enzyme and Ethylenediaminetetraacetic acid (EDTA) as decellularization agents. Three protocols of cyclic trachea decellularization (Protocols A, B, and C) were compared. Following Protocol A (previously described in the literature), 15 consecutive cycles were performed over 32 days. Protocol B (a variation of Protocol A) — EDTA being added — with 15 consecutive cycles performed over 60 days. Finally, Protocol C, with the addition of Trypsin as a decellularization agent, 5 consecutive cycles being performed over 10 days. For the three protocols, hematoxylin–eosin (H&E) staining and DNA residual content quantification were performed to establish the effectiveness of the decellularization process. Scanning Electron Microscopy (SEM) was used to observe the changes in porosity and microarrays. To evaluate the structural matrices integrity, Thermogravimetric Analysis (TGA) and biomechanical test were used. None of the protocols showed significant alteration or degradation in the components of the extracellular matrix

  6. Using tracheal segments for replacement of cervical oesophagus: an experimental study.

    Science.gov (United States)

    Abbasidezfouli, Azizollah; Sharifi, Davood; Sasani, Farhang; Ansari, Damoon; Abarkar, Mohammad; Rahmanijoo, Nasrin; Abbasidezfouli, Golbahar; Sheikhy, Kambiz

    2012-03-01

    Segmental resection and anastomosis of oesophageal lesions are not performed as a routine clinical practice because of complications and associated problems, whereas tracheal resection and anastomosis are a routine clinical practice. In this experimental study, we resected a segment of cervical oesophagus and replaced it with a tracheal segment. In eight dogs (mixed races), weighing 20-30 kg, ageing 1-2 years, under general anaesthesia, through a cervical incision, 5 cm of cervical trachea was separated while preserving its attachments to surrounding fibroareolar tissues. Afterwards, 5 cm of the oesophagus was resected and replaced with a prepared segment of the trachea. Oral liquids were started at the first post-operative day; the animals were kept for 2 months and then euthanized. Quality of swallowing and voice were evaluated. After an autopsy, anastomoses were examined grossly and histopathologically. No complications occurred during surgery. Swallowing function and voice were normal in all eight dogs after the operation. No sign of aspiration was seen in clinical and radiographic examinations after starting oral diet. In autopsy examination, anastomoses were patent without narrowing or abnormal mucosal changes. Remarkable histopathological findings in replaced tracheal segments were squamous metaplasia, atrophy and degeneration of mucosal glands and degeneration of cartilages. Replacement of a segment of the oesophagus with an autogenous tracheal segment is a practical procedure with low complications and can probably be used for the treatment of cervical oesophageal lesions in human beings.

  7. Regeneration of tracheal epithelium using mouse induced pluripotent stem cells.

    Science.gov (United States)

    Ikeda, Masakazu; Imaizumi, Mitsuyoshi; Yoshie, Susumu; Otsuki, Koshi; Miyake, Masao; Hazama, Akihiro; Wada, Ikuo; Omori, Koichi

    2016-01-01

    Conclusion The findings demonstrated the potential use of induced pluripotent stem cells for regeneration of tracheal epithelium. Objective Autologous tissue implantation techniques using skin or cartilage are often applied in cases of tracheal defects with laryngeal inflammatory lesions and malignant tumor invasion. However, these techniques are invasive with an unstable clinical outcome. The purpose of this study was to investigate regeneration in a tracheal defect site of nude rats after implantation of ciliated epithelium that was differentiated from induced pluripotent stem cells. Method Embryoid bodies were formed from mouse induced pluripotent stem cells. They were cultured with growth factors for 5 days, and then cultured at the air-liquid interface. The degree of differentiation achieved prior to implantation was determined by histological findings and the results of real-time polymerase chain reaction. Embryoid bodies including ciliated epithelium were embedded into collagen gel that served as an artificial scaffold, and then implanted into nude rats, creating an 'air-liquid interface model'. Histological evaluation was performed 7 days after implantation. Results The ciliated epithelial structure survived on the lumen side of regenerated tissue. It was demonstrated histologically that the structure was composed of ciliated epithelial cells.

  8. Resection and anastomosis for benign tracheal stenosis: Single institution experience of 18 cases.

    Science.gov (United States)

    Kumar, Arvind; Asaf, Belal Bin; Puri, Harsh Vardhan; Abdellateef, Amr

    2017-01-01

    Tracheal stenosis is a complex condition caused by altered inflammatory response to injury and subsequent excessive circumferential scar formation. Surgical resection, wherever possible, offers the best long-term results. Nonsurgical methods provide immediate relief to all can be curative in few but mostly serve as an excellent bridge to surgery in majority. The purpose of this study is to retrospectively evaluate the outcome following surgery for benign tracheal stenosis at our center. This retrospective analysis was conducted on 18 patients who underwent resection and anastomosis for tracheal stenosis at our center between March 2012 and December 2015. Their records were analyzed for demography, history, clinical presentation, computed tomography, bronchoscopy details, preoperative interventions, indications for and details of surgery, the procedure performed, postoperative complications, and course during 6 months follow-up. The patients had a varied list of pathologies for which they were either intubated or tracheostomized. The length of stenosis ranged between 1 cm and 4 cm. The diameter of stenotic segment ranged between 0 mm and 10 mm. Average length of resected segment was 3 cm, and number of tracheal rings resected ranged from 2 to 9. Postoperative complications occurred in four patients (22.22%). All our patients were in the "excellent outcome" category at discharge as well as at 3 months follow-up. Surgical management of tracheal stenosis is challenging and requires multidisciplinary team approach. Thorough preoperative preparation and multidisciplinary planning regarding need for and timing of surgery, meticulous intraoperative technique, and aggressive postoperative care is key to successful surgery, which can provide long-lasting cure to these patients.

  9. A simple method for accurate endotracheal placement of an intubation tube in Guinea pigs to assess lung injury following chemical exposure.

    Science.gov (United States)

    Nambiar, M P; Gordon, R K; Moran, T S; Richards, S M; Sciuto, A M

    2007-01-01

    ABSTRACT Guinea pigs are considered as the animal model of choice for toxicology and medical countermeasure studies against chemical warfare agents (CWAs) and toxic organophosphate pesticides because of the low levels of carboxylesterase compared to rats and mice. However, it is difficult to intubate guinea pigs without damaging the larynx to perform CWA inhalation experiments. We describe an easy technique of intubation of guinea pigs for accurate endotracheal placement of the intubation tube. The technique involves a speculum made by cutting the medium-size ear speculum in the midline leaving behind the intact circular connector to the otoscope. Guinea pigs were anesthetized with Telazol/meditomidine, the tongue was pulled using blunt forceps, and an otoscope attached with the specially prepared speculum was inserted gently. Insertion of the speculum raises the epiglottis and restrains the movements of vocal cord, which allows smooth insertion of the metal stylet-reinforced intubation tube. Accurate endotracheal placement of the intubation tube was achieved by measuring the length from the tracheal bifurcation to vocal cord and vocal cord to the upper front teeth. The average length of the trachea in guinea pigs (275 +/- 25 g) was 5.5 +/- 0.2 cm and the distance from the vocal cord to the front teeth was typically 3 cm. Coinciding an intubation tube marked at 6 cm with the upper front teeth accurately places the intubation tube 2.5 cm above the tracheal bifurcation. This simple method of intubation does not disturb the natural flora of the mouth and causes minimum laryngeal damage. It is rapid and reliable, and will be very valuable in inhalation exposure to chemical/biological warfare agents or toxic chemicals to assess respiratory toxicity and develop medical countermeasures.

  10. The preventive effects of natural adjuvants, G2 and G2F on tracheal responsiveness and serum IL-4 and IFN-γ (th1/th2 balance in sensitized guinea pigs

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Boskabady

    2014-07-01

    Full Text Available OBJECTIVE:The effects of natural adjuvants on lung inflammation and tracheal responsiveness were examined in sensitized guinea pigs.METHODS:The responses of guinea pig tracheal chains and the serum levels of interleukin-4 and interferon-gamma were examined in control pigs and three other groups of guinea pigs: the sensitized group and two other sensitized groups treated with either adjuvant G2 or adjuvant G2F (n = 7 for each group. Sensitization of the animals was achieved by injection and inhalation of ovalbumin.RESULTS:The results showed that sensitized animals had increased tracheal responsiveness and increased serum levels of interleukin-4 and interferon-gamma compared to controls (p<0.05 to p<0.001. Treatments with either G2 or G2F prevented the increase in tracheal responsiveness and serum interleukin-4 (p<0.01 to p<0.001. However, the serum levels of interferon-gamma and the interleukin-4-to-interferon-gamma ratio was increased in the treated groups (p<0.001 for all cases.CONCLUSIONS:These results indicate important preventive effects of two natural adjuvants, particularly G2, on the changes in tracheal responsiveness, serum cytokines and the interleukin-4-to-interferon-gamma ratio (T helper 1/T helper 2 balance in sensitized guinea pigs.

  11. Inhibiting CXCL12 blocks fibrocyte migration and differentiation and attenuates bronchiolitis obliterans in a murine heterotopic tracheal transplant model.

    Science.gov (United States)

    Harris, David A; Zhao, Yunge; LaPar, Damien J; Emaminia, Abbas; Steidle, John F; Stoler, Mark; Linden, Joel; Kron, Irving L; Lau, Christine L

    2013-03-01

    Fibrocytes are integral in the development of fibroproliferative disease after lung transplantation. Undifferentiated fibrocytes (CD45+anti-collagen 1+CXCR4+) preferentially traffic by way of the CXCR4/CXCL12 axis and differentiate into smooth muscle actin-producing (CD45+CXCR4+α-smooth muscle actin+) cells. We postulated that an antibody directed against CXCL12 would attenuate fibrocyte migration and fibro-obliteration of heterotopic tracheal transplant allografts. A total alloantigenic mismatch murine heterotopic tracheal transplant model of obliterative bronchiolitis was used. The mice were treated with either goat-anti-human CXCL12 F(ab')(2) or goat IgG F(ab')(2). Buffy coat, bone marrow, and trachea allografts were collected and analyzed using flow cytometry. Tracheal luminal obliteration was assessed using hematoxylin-eosin and Direct Red 80 collagen stain. Compared with the controls, the anti-CXCL12-treated mice showed a significant decrease in tracheal allograft fibrocyte populations at 7 and 21 days after transplantation. Bone marrow and buffy coat aspirates showed the same trend at 7 days. In the anti-CXCL12-treated mice, there was a 35% decrease in luminal obliteration at 21 days (65% vs 100% obliterated; interquartile range, 38% vs 10%; P = .010) and decreased luminal collagen deposition at 21 and 28 days after transplantation (P = .042 and P = .012, respectively). Understanding the role of fibrocytes in airway fibrosis after lung transplantation could lead to a paradigm shift in treatment strategy. Anti-CXCL12 antibody afforded protection against infiltrating fibrocytes and reduced the deterioration of the tracheal allografts. Thus, the CXCR4/CXCL12 axis is a novel target for the treatment of fibro-obliteration after lung transplantation, and the quantification of fibrocyte populations could provide clinicians with a biomarker of fibrosis, allowing individualized drug therapy. Copyright © 2013 The American Association for Thoracic Surgery. Published

  12. Tracheal compression due to an elongated aortic arch in patients with congenital heart disease: evaluation using multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Noriko; Hayabuchi, Yasunobu; Inoue, Miki; Sakata, Miho; Nabo, Manal Mohamed Helmy; Nakagawa, Ryuji; Saijo, Takahiko; Kagami, Shoji [University of Tokushima, Department of Pediatrics, Tokushima (Japan)

    2009-10-15

    The airway can become obstructed as a result of compression by an elongated aortic arch. In this study we evaluated tracheal compression using multidetector-row CT in patients with congenital heart disease and an elongated aortic arch. The trachea was measured at the level of the aortic arch in 205 children and young adults and then the severity of tracheal compression was determined by measuring the tracheal diameter ratio (short axis diameter/long axis diameter). Patients were divided as follows: group I (normal aortic arch; n=166), group II (transversely running aortic arch; n=22), and group III (elongated aortic arch; n=17). From the viewpoint of the relationship of the great arteries, group II had D-malposition, and group III had L-malposition. Age, height, weight and body surface area were significantly correlated with the short and long axis diameter in group I. There was a negative correlation between tracheal diameter ratio and the physical size parameters. The tracheal diameter ratio in group III was 0.50{+-}0.13, which was significantly lower than in groups I and II (P<0.01 and 0.05, respectively). Even apparently asymptomatic patients with an elongated aortic arch can have tracheal compression. An elongated aortic arch may be a useful predictor of tracheal compression. (orig.)

  13. Multimodal non-surgical treatment of a feline tracheal adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Carolina Azevedo

    2017-02-01

    Full Text Available Case summary A 10-year-old, castrated male domestic shorthair cat presented with a 2–3 month history of weight loss, lethargy and coughing. Thoracic radiographs revealed a soft tissue opacity overlying the dorsal trachea from the first rib to second rib and the ventral aspect of the trachea extending from the second rib to approximately the fourth rib. CT confirmed a mass involving the dorsal, right lateral and ventral aspects of the trachea narrowing the lumen and extending from vertebra C7 through T4. Bronchoscopy revealed a partially circumferential irregular and multilobulated tracheal mass, which was biopsied. The histopathological diagnosis was tracheal adenocarcinoma. The cat was treated with a definitive course of external beam radiation therapy (RT; 3 Gy × 18, cytotoxic chemotherapy, a tyrosine kinase inhibitor and palliative RT. The cat remained asymptomatic for 2 months and the mass remained stable radiographically for 11 months after RT. Relevance and novel information With multimodal treatment the cat had a survival time of 755 days. Initial treatment included definitive RT, carboplatin and piroxicam, followed by toceranib phosphate and palliative RT when the mass recurred. This case report describes the first documented use of non-surgical treatment and long-term outcome of tracheal adenocarcinoma in a cat. This case report is an indication that prolonged survival can be achieved with multimodal therapy.

  14. Thyroidectomy improves tracheal anatomy and airflow in patients with nodular goiter. A prospective cohort study

    DEFF Research Database (Denmark)

    Sørensen, Jesper Roed; Lauridsen, Jeppe Killerich; Døssing, Helle

    . Effect sizes (ES) were calculated as mean change divided by standard deviation at baseline. ES of 0.2-0.5 were defined as small, 0.5-0.8 as moderate, and values >0.8 as large.Results: Sixty-five patients completed all examinations. Median goiter volume was 58 mL (range, 14-642 mL) before surgery...... resonance images (MRI) of the neck and respiratory flow-volume curves, including both in- and expiration, were performed prior to and six months following surgery. The evaluated tracheal dimensions included the smallest cross-sectional area of the trachea (SCAT), tracheal narrowing, and tracheal deviation...... with surgical removal of median 43 g (range, 8-607 mL). Six months post-surgery, tracheal narrowing and deviation were diminished by median 26% (ES=0.67), and 33% (ES=0.73), respectively, while SCAT increased by 17% (ES=0.61). Correspondingly, each 10% decrease in goiter volume resulted in an increase of 6...

  15. Idiopathic tracheal stenosis: a clinicopathologic study of 63 cases and comparison of the pathology with chondromalacia.

    Science.gov (United States)

    Mark, Eugene J; Meng, Fanqing; Kradin, Richard L; Mathisen, Douglas J; Matsubara, Osamu

    2008-08-01

    Tracheal stenosis in adults usually is the result of mechanical injuries either from direct trauma or intubation. Rarely do cases develop in patients without such a precedent history, and there are few reports of the pathology of idiopathic tracheal stenosis (ITS). We reviewed clinicopathologically, 63 tracheal resections for tracheal stenosis in patients who had no antecedent explanation for their stenosis. We contrasted these 63 cases with 34 cases of tracheal stenosis owing to chondromalacia (CM) after mechanical injury. All 63 cases occurred in females, with a mean age of 49 years. The most common symptom was dyspnea on exertion. The average duration of symptoms was greater than 2 years. One-third of the patients gave a history of gastroesophageal reflux. All but one of the cases occurred in the subglottic region and/or upper one-third of the trachea. Pathologically, most cases showed extensive keloidal fibrosis and dilation of mucus glands, a finding that was not obvious in most cases of CM. ITS has relatively normal cartilage with smooth inner and outer perichondrium, whereas CM has extensive degeneration of cartilage with irregular border of inner perichondrium observable at shirt sleeve magnification. Immunohistochemical staining for estrogen receptor and progesterone receptor was positive in fibroblasts cells in most cases. ITS is a rare disease and restricted to females. It may represent some form of fibromatosis. ITS can be distinguished histologically from CM in tracheal resection specimens in most cases.

  16. Wear plates control rod guide tubes top internal reactor vessel C. N. VANDELLOS II

    International Nuclear Information System (INIS)

    2010-01-01

    The guide tubes for control rods forming part of the upper internals of the reactor vessel, its function is to guide the control rod to permit its insertion in the reactor core. These guide tubes are suspended from the upper support plate which are fixed by bolts and extending to the upper core plate which is fastened by clamping bolts (split pin) to prevent lateral displacement of the guide tubes, while allowing axial expansion.

  17. Balloon dilation and airway stenting for benign and malignant tracheal stenosis

    International Nuclear Information System (INIS)

    Guo Jianhai; Yang Renjie; Zhang Hongzhi

    2009-01-01

    Objective: To assess the effectiveness of balloon dilation and airway stenting performed under fluoroscopic guidance for the treatment of benign and malignant tracheal stenosis. Methods: Under fluoroscopic guidance, balloon dilation and airway stenting were performed in 45 patients with tracheobronchial stricture. Of the 45 patients,malignant tracheal stenosis was seen in 37, including mediastinal nodal metastases (n=14), esophageal carcinoma (n=13), lung carcinoma (n= 4), adenocarcinoma of bronchus (n=3), lymphoma (n=2) and laryngocarcinoma (n=1), and benign tracheal stenosis was seen in 8, including endobronchial tuberculosis (n=6), retrosternal thyroid adenoma (n=1) and endotracheal intubation (n=1). Airway stenting with self-expandable metal stent was employed in 38 patients and balloon dilation in 7 patients. All the procedures were performed under fluoroscopic guidance. Results: A total of 53 self-expandable metal stents was implanted in 38 patients. The clinical symptoms were immediately relived after the procedure in all patients except for one patient who died from choking of sputum. No stent migration was observed. Restenosis developed in 4 patients, which was successfully treated with repeated stenting and balloon dilation. Nineteen times of balloon dilation procedure were accomplished in 7 patients. Marked remission of clinical symptoms was seen in most cases. During a follow-up period (ranged from 0 to 124 months with a mean of 24.5 months) 31 patients died. Conclusion: For both benign and malignant tracheal stenosis, balloon dilation with airway stenting performed under fluoroscopic guidance is a safe and efficient therapy with instant curative effect in relieving clinical symptoms. (authors)

  18. Predictive value of α-amylase in tracheal aspirates for ventilator-associated pneumonia in elderly patients.

    Science.gov (United States)

    Qu, Ge-Ping; Fang, Xiang-Qun; Xu, Ya-Ping; Shi, Min; Wang, Yang; Gong, Mei-Liang; Fang, Hao-Ming

    2018-04-01

    This study aims to investigate the correlation between α-amylase in tracheal aspirates and risk factors of aspiration, as well as ventilator-associated pneumonia (VAP), in elderly patients undergoing mechanical ventilation and explore the clinical value of α-amylase for predicting VAP. Tracheal aspirates were collected from elderly patients within 2 weeks after tracheal intubation in mechanical ventilation, and α-amylase was detected. Patients were grouped according to the presence of VAP. The correlation between α-amylase and risk factors of aspiration before intubation, as well as VAP, were analyzed. The sample of this study comprised 147 patients. The average age of these patients was 86.9 years. The incidence of VAP was 21% during the study period. Tracheal aspirate α-amylase level increased with the increase in the number of risk factors for aspiration before intubation, α-amylase level was significantly higher in the VAP group than in the non-VAP group, the area under the receiver operating characteristic curve (ROC) of the diagnostic value of α-amylase for VAP was 0.813 (95% CI: 0.721-0.896), threshold value was 4,681.5 U/L, sensitivity was 0.801 and specificity was 0.793. Logistic multivariate analysis revealed the following risk factors for VAP: a number of risk factors before intubation of ≥3, a Glasgow score of aspiration of subglottic secretion and a tracheal aspirate α-amylase level of >4681.5 U/L. Tracheal aspirate α-amylase can serve as a biomarker for predicting VAP in elderly patients undergoing mechanical ventilation. © 2017 John Wiley & Sons Ltd.

  19. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    Langford, O.M.; Peelman, H.E.

    1980-01-01

    A gas filled neutron tube in a nuclear well logging tool has a target an ion source voltage and a replenisher connected to ground. A negative high voltage is applied to the target by a power supply also providing a target current corresponding to the neutron output of the neutron generator tube. A constant current source provides a constant current. A network receiving the target current and the constant current provides a portion of the constant current as a replenisher current which is applied to the replenisher in a neutron generating tube. The network controls the magnitude of the replenisher current in accordance with the target current so as to control the neutron output of the neutron generating tube. (auth)

  20. Resection and anastomosis for benign tracheal stenosis: Single institution experience of 18 cases

    Directory of Open Access Journals (Sweden)

    Arvind Kumar

    2017-01-01

    Full Text Available Introduction: Tracheal stenosis is a complex condition caused by altered inflammatory response to injury and subsequent excessive circumferential scar formation. Surgical resection, wherever possible, offers the best long-term results. Nonsurgical methods provide immediate relief to all can be curative in few but mostly serve as an excellent bridge to surgery in majority. The purpose of this study is to retrospectively evaluate the outcome following surgery for benign tracheal stenosis at our center. Materials and Methods: This retrospective analysis was conducted on 18 patients who underwent resection and anastomosis for tracheal stenosis at our center between March 2012 and December 2015. Their records were analyzed for demography, history, clinical presentation, computed tomography, bronchoscopy details, preoperative interventions, indications for and details of surgery, the procedure performed, postoperative complications, and course during 6 months follow-up. Results: The patients had a varied list of pathologies for which they were either intubated or tracheostomized. The length of stenosis ranged between 1 cm and 4 cm. The diameter of stenotic segment ranged between 0 mm and 10 mm. Average length of resected segment was 3 cm, and number of tracheal rings resected ranged from 2 to 9. Postoperative complications occurred in four patients (22.22%. All our patients were in the “excellent outcome” category at discharge as well as at 3 months follow-up. Conclusions: Surgical management of tracheal stenosis is challenging and requires multidisciplinary team approach. Thorough preoperative preparation and multidisciplinary planning regarding need for and timing of surgery, meticulous intraoperative technique, and aggressive postoperative care is key to successful surgery, which can provide long-lasting cure to these patients.

  1. Analysis of DC control in double-inlet GM type pulse tube refrigerators for detectors

    Science.gov (United States)

    Du, B. Y.

    2016-10-01

    Pulse tube refrigerators have demonstrated many advantages with respect to temperature stability, vibration, reliability and lifetime among cryo-coolers for detectors. Double-inlet type pulse tube refrigerators are popular in GM type pulse tube refrigerators. The single double-inlet valve may introduce DC flow in refrigerator, which deteriorates the performance of pulse tube refrigerator. One new type of DC control mode is introduced in this paper. Two parallel-placed needle valves with opposite direction named double-valve configuration, instead of single double-inlet valve, are used in our experiment to reduce the DC flow. With two double-inlet operating, the lowest cold end temperature of 18.1K and a coolant of 1.2W@20K have been obtained. It has proved that this method is useful for controlling DC flow of the pulse tube refrigerators, which is very important to understand the characters of pulse tube refrigerators for detectors.

  2. trans-Caryophyllene, a Natural Sesquiterpene, Causes Tracheal Smooth Muscle Relaxation through Blockade of Voltage-Dependent Ca2+ Channels

    Directory of Open Access Journals (Sweden)

    Jader Santos Cruz

    2012-10-01

    Full Text Available trans-Caryophyllene is a major component in the essential oils of various species of medicinal plants used in popular medicine in Brazil. It belongs to the chemical class of the sesquiterpenes and has been the subject of a number of studies. Here, we evaluated the effects of this compound in airway smooth muscle. The biological activities of trans-caryophyllene were examined in isolated bath organs to investigate the effect in basal tonus. Electromechanical and pharmacomechanical couplings were evaluated through the responses to K+ depolarization and exposure to acetylcholine (ACh, respectively. Isolated cells of rat tracheal smooth muscle were used to investigate trans-caryophyllene effects on voltage-dependent Ca2+ channels by using the whole-cell voltage-clamp configuration of the patch-clamp technique. trans-Caryophyllene showed more efficiency in the blockade of electromechanical excitation-contraction coupling while it has only minor inhibitory effect on pharmacomechanical coupling. Epithelium removal does not modify tracheal smooth muscle response elicited by trans-caryophyllene in the pharmacomechanical coupling. Under Ca2+-free conditions, pre-exposure to trans-caryophyllene did not reduce the contraction induced by ACh in isolated rat tracheal smooth muscle, regardless of the presence of intact epithelium. In the whole-cell configuration, trans-caryophyllene (3 mM, inhibited the inward Ba2+ current (IBa to approximately 50% of control levels. Altogether, our results demonstrate that trans-caryophyllene has anti-spasmodic activity on rat tracheal smooth muscle which could be explained, at least in part, by the voltage-dependent Ca2+ channels blockade.

  3. Application of radioisotope methods of investigation and control techniques in tube production

    International Nuclear Information System (INIS)

    Chizh, V.A.; Drabkin, L.A.

    1975-01-01

    Various spheres of radioactive isotopes application of closed and open type in tube production are described. Due to the usage of radioactive indicator method in combination with physicochemical methods and metallography new data are obtained in the theory and practice of tube centrifugal casting, rolling and pressing. Adsorption properties of lubricants and element distribution in the joint weld region of the big diameter tubes are investigated. The application of radioactive isotopes as ionizing radiation source made it possible to develop some radioisotope methods and instruments for tube wall thickness and the wall thickness difference control. Short characteristics of such instruments are given

  4. Recurrent airway obstructions in a patient with benign tracheal stenosis and a silicone airway stent: a case report

    OpenAIRE

    Sriram, KB; Robinson, PC

    2008-01-01

    Airway stents (silicone and metal stents) are used to treat patients with benign tracheal stenosis, who are symptomatic and in whom tracheal surgical reconstruction has failed or is not appropriate. However airway stents are often associated with complications such as migration, granuloma formation and mucous hypersecretion, which cause significant morbidity, especially in patients with benign tracheal stenosis and relatively normal life expectancy. We report a patient who had frequent critic...

  5. A prehospital use of ITClamp for haemostatic control and fixation of a chest tube

    DEFF Research Database (Denmark)

    Barnung, S; Steinmetz, J

    2014-01-01

    We here present three cases in which a new device, the ITClamp Hemorrhage Control System (Innovative Trauma Care, Inc., Edmonton, Canada), was used for bleeding control and for securing a chest tube.......We here present three cases in which a new device, the ITClamp Hemorrhage Control System (Innovative Trauma Care, Inc., Edmonton, Canada), was used for bleeding control and for securing a chest tube....

  6. A case of tracheal leiomyoma misdiagnosed as asthma.

    Science.gov (United States)

    Öztürk, Ayperi; Aktaş, Zafer; Yılmaz, Aydın; Yeşildağlı, Havva; Memiş, Leyla

    2016-12-01

    Primary benign tumors of trachea are rare. Of them, tracheal leiomyoma, constitutes only 1% of all benign lower respiratory tract tumors. Here, we present a case of tracheal leiomyoma who has been receiving high doses of inhaled corticosteroids and bronchodilators for a year with a misdiagnosis of asthma. As the symptoms did not resolve with an overtreatment, she has been undergone radiologic study to find a possible alternative diagnosis. The chest roentgenogram revealed an opacity in the upper mediastinum. In computed tomography, a lesion has been detected in proximal trachea, arising from the posterior wall and protruding through the lumen and almost obliterating the air column. Rigid bronchoscopy has been performed under general anesthesia due to a high risk of bleeding and the endobronchial lesion, freely moving with respiration, has been removed and cryotherapy was applied to the base of the lesion. Receiving the histopathological diagnosis of leiomyoma, the patient is now on 12th month of the follow-up without any recurrence.

  7. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    1980-01-01

    A specification is given for an energizing and regulating circuit for a gas filled neutron generator tube consisting of a target, an ion source and a replenisher, the circuit consisting of a power supply to provide a negative high voltage to the target and a target current corresponding to the neutron output of the tube, a constant current source, and control means connected to the power supply and to the constant current source, the control means being responsive to the target current to provide a portion of the constant current to the replenisher substantially to regulate the neutron output of the tube. (author)

  8. Complication following primary repair of a penetrating bull horn injury to the trachea

    Directory of Open Access Journals (Sweden)

    Khan Mozaffar

    2008-01-01

    Full Text Available A 22-year-old male patient was admitted to the casualty with a bull horn injury in the lower zone of the neck in the midline. The patient was conscious and distressed but hemodynamically stable. Local examination revealed a lacerated wound. He underwent emergency primary repair of the wound under halothane anesthesia; intubation was done keeping in readiness all preparations for difficult airway management. Postoperatively, elective controlled ventilation was performed with continuous infusion of muscle relaxant. After approximately 8 hours of controlled ventilation, the syringe pump failed; this initially went unnoticed and made the patient cough and buck on the tube. Infusion was restarted after a bolus dose of vecuronium bromide intravenously but, meanwhile, the patient developed subcutaneous emphysema in the neck. He was immediately transferred to the operating room, where exploration of the surgical site revealed dehiscence of the tracheal wound; this had led to the subcutaneous emphysema. Repair of the tracheal wound dehiscence was not possible due to both lack of space and lack of tissue for apposition. Hence, a tracheostomy tube was inserted through the tracheal wound and the patient was transferred to the intensive care unit for elective controlled ventilation. The patient was weaned off the ventilator within 24 h and transferred to the surgical ward on spontaneous ventilation with the tracheostomy tube in situ. The size of the patient′s tracheostomy tube was reduced gradually by the serial exchange method. The wound ultimately healed with minimal scarring.

  9. Tracheal Constriction In A Growing Dog

    OpenAIRE

    DeArmond, Christina; Niimura del Barrio, Maria Chie; Rosati, Tomasso; McAllister, Hester; Ryan, John

    2017-01-01

    A six-month-old castrated male German Shepherd/Husky cross was presented for investigation of a progressive dyspnoea and regurgitation. A circumferential cervical wound had been identified and closed following debridement by the primary care veterinarian when the dog was three months old. There was an extraluminal tracheal compression on radiographs. Surgical exploration revealed a plastic band tied and embedded in the dorsal musculature of the neck. The band had been increasingly constrictin...

  10. Volume Threshold for Chest Tube Removal: A Randomized ‎Controlled Trial

    Directory of Open Access Journals (Sweden)

    Sajad Hatami

    2009-07-01

    Full Text Available Background: Despite importance of chest tube insertion in chest trauma, there is no ‎general agreement on the level of daily volume drainage from chest tube. This study ‎was conducted to compare the effectiveness and safety of chest tube removal at the ‎levels of 150 ml/day and 2oo ml/day. Methods: Eligible patients (138 who needed replacement of chest tube (because of ‎trauma or malignancy were randomized into two groups; control (removal of chest tube ‎when drainage reached to 150 ml/day and trial (removal of chest tube at the level of ‎‎200 ml/day. All patients received standard care during hospital admission and a follow-‎up visit after 7days of discharge from hospital. Patients were then compared in terms of ‎major clinical outcomes using chi-squared and t-test. Results: From the total of 138 patients, 70 and 68 patients were randomized to control ‎‎(G150 and trial (G200 group, respectively. Baseline characteristics were comparable ‎between the two groups. Although the trial group had a shorter mean for length of ‎hospital stay (LOS (4.1 compared to 4.8, p=0.04, their differences in drainage time ‎did not reach to the level of statistical significance (p=0.1. Analysis of data showed no ‎statistically significant differences between the rate of radiological reaccumulation, ‎thoracentesis and decrease in pulmonary sounds (auscultatory, one week after ‎discharge from hospital.‎‏ ‏Conclusions: Compared to a daily volume drainage of 150 ml, removal of chest tube ‎when there is 200 ml/day is safe and will even result in a shorter hospital stay. This in ‎turn leads to a lower cost.‎

  11. Heart Sound Localization and Reduction in Tracheal Sounds by Gabor Time-Frequency Masking

    OpenAIRE

    SAATCI, Esra; Akan, Aydın

    2018-01-01

    Background and aim: Respiratorysounds, i.e. tracheal and lung sounds, have been of great interest due to theirdiagnostic values as well as the potential of their use in the estimation ofthe respiratory dynamics (mainly airflow). Thus the aim of the study is topresent a new method to filter the heart sound interference from the trachealsounds. Materials and methods: Trachealsounds and airflow signals were collected by using an accelerometer from 10 healthysubjects. Tracheal sounds were then pr...

  12. [Use of Airwayscope with pediatric intlock in a patient with first and second branchial arch syndrome].

    Science.gov (United States)

    Kubota, Aiko; Takeda, Akiko; Arai, Toshimi; Murozono, Michihiro

    2013-12-01

    First and second branchial arch syndrome is a congenital anomaly of craniofacial dysplasia involving organs derived from the second branchial arch. The main characteristics are microtia and mandibular hypoplasia. A 6-year-old boy was scheduled for adenoidectomy and bilateral myringotomy and tube placement. Slow induction was performed with oxygen, nitrous oxide, and sevoflurane. No difficulties were encountered during mask ventilation, and rocuronium was administered intravenously. His epiglottis was not visible during laryngoscopy. Therefore, we used the Airwayscope (AWS). His glottis was visible after application of cricold pressure from the left side. However, we could not closely conform his epiglottis to the mark on the AWS. Therefore, we passed a fiberoptic bronchoscope through a tracheal tube and placed it in the AWS. We attempted to intubate the trachea, but could not guide the bronchoscope to his glottis. We then attempted to pull the tracheal tube to improve the mobility of the bronchoscope. Control of the bronchoscope consequently became easy We successfully guided it to his glottis and performed tracheal intubation. His condition was stable during the procedure. In conclusion, we safely performed tracheal intubation in a patient with first and second branchial arch syndrome using the AWS and a fiberoptic bronchoscope.

  13. Transoral tracheal intubation of rodents using a fiberoptic laryngoscope.

    Science.gov (United States)

    Costa, D L; Lehmann, J R; Harold, W M; Drew, R T

    1986-06-01

    A fiberoptic laryngoscope which allows direct visualization of the deep pharynx and epiglottis has been developed for transoral tracheal intubation of small laboratory mammals. The device has been employed in the intubation and instillation of a variety of substances into the lungs of rats, and with minor modification, has had similar application in mice, hamsters, and guinea pigs. The simplicity and ease of handling of the laryngoscope permits one person to intubate large numbers of enflurane anesthetized animals either on an open counter top or in a glove-box, as may be required for administration of carcinogenic materials. Instillation of 7Be-labeled carbon particles into the lungs of mice, hamsters, rats, and guinea pigs resulted in reasonably consistent interlobal distribution of particles for each test animal species with minimal tracheal deposition. However, actual lung tissue doses of carbon exhibited some species dependence.

  14. Effect of aging on tracheal mucociliary clearance in Beagle dogs

    International Nuclear Information System (INIS)

    Whaley, S.L.; Muggenburg, B.A.; Wolff, R.K.

    1985-01-01

    Tracheal mucous velocity measurements were made in 24 Beagle dogs, in 5 age groups, using a gamma camera to detect movement on instilled radiolabeled material. Age groups were defined as immature, young adult, middle-aged, mature, and aged dogs. Mean velocities (+/- SE) were 3.6 +/- 0.4 mm/min in the immature dogs, 9.8 +/- 0.7 mm/min in the young adults, 6.9 +/- 0.5 mm/min in the middle-aged dogs, 3.6 +/- 1.1 mm/min in the mature dogs, and 2.8 +/- 0.6 mm/min in the aged dogs. Tracheal mucous velocity was significantly faster in the young adult and middle-aged groups than in the immature, mature, and aged dog groups. 4 references, 1 figure, 1 table

  15. Relaxing action of adrenergic β2-agonists on guinea-pig skinned tracheal muscle

    Directory of Open Access Journals (Sweden)

    Kayo Nemoto

    1999-01-01

    Full Text Available Although adrenergic β2-agonist-induced smooth muscle relaxation has been attributed to increased intracellular cyclic AMP (cAMP, a relaxation response has been observed at low β2-agonist concentrations that do not cause increased cAMP To elucidate the mechanism of tracheal muscle relaxation induced by low concentrations of β2-agonists, we used a guinea-pig skinned tracheal smooth muscle preparation to examine the effects on the contractile protein system. The isotonic contraction of β-escin-treated skinned tracheal muscle from guinea-pig was measured. When the intracellular Ca2+ concentration was maintained at 1 μmol/L in the presence of guanosine 5′-triphosphate (GTP; 100 μmol/L, neither isoproterenol (10nmol/L nor salbutamol (60 nmol/L affected Ca2+ sensitivity, but a significant decrease in Ca2+ sensitivity was observed in the presence of okadaic acid (1 μmol/L. The decrease in Ca2+ sensitivity was a slow response and was blocked by pretreatment with propranolol (1 μmol/L. Forskolin (1 μmol/L did not affect Ca2+ sensitivity. These results suggest that adrenergic b 2-agonists may activate protein phosphatase through an unknown pathway involving the β2-receptor, which enhances dephosphorylation of the myosin light chain and/or thin filament proteins, resulting in relaxation of the tracheal smooth muscle.

  16. Improvements to the power supply and control systems of Geiger-Mueller counter tubes

    International Nuclear Information System (INIS)

    Gavin, Gerard; Amberny, Philippe.

    1977-01-01

    This invention aims to provide a power supply and control system for Geiger-Mueller counter tubes requiring only one high voltage output, corresponding to the 'active' phase voltage. With this in view, the invention proposes, inter alia, a system comprising a high voltage source connected to the anode of the GM tube whose cathode is connected to a determination and counting circuit, featuring a cathode connected to the source via an electronic switch and to earth by a component for holding the potential difference at a given level and by another electronic switch, placed in series. The switches are controlled in turn so as alternately to bring the cathode to a first voltage, enabling the tube to function, and to a second voltage, causing the blocking of the tube, this second voltage being set by the component creating the voltage difference [fr

  17. Improvements to the power supply and control systems of Geiger-Mueller counter tubes

    Energy Technology Data Exchange (ETDEWEB)

    Gavin, G; Amberny, P

    1977-10-19

    This invention aims to provide a power supply and control system for Geiger-Mueller counter tubes requiring only one high voltage output, corresponding to the 'active' phase voltage. With this in view, the invention proposes, inter alia, a system comprising a high voltage source connected to the anode of the GM tube whose cathode is connected to a determination and counting circuit, featuring a cathode connected to the source via an electronic switch and to earth by a component for holding the potential difference at a given level and by another electronic switch, placed in series. The switches are controlled in turn so as alternately to bring the cathode to a first voltage, enabling the tube to function, and to a second voltage, causing the blocking of the tube, this second voltage being set by the component creating the voltage difference.

  18. Tracheal stenosis: our experience at a tertiary care centre in India with special regard to cause and management.

    Science.gov (United States)

    Nair, Satish; Mohan, Sharad; Mandal, Ghanashyam; Nilakantan, Ajith

    2014-01-01

    Tracheal stenosis (TS), a challenging problem, is a known complication of prolonged intubation and tracheostomy. The management involves a multidisciplinary approach with multiple complex procedures. In this study we discuss our experience with severe TS with regards to patient characteristics, cause and management. A retrospective analysis of 20 patients of severe TS treated at a tertiary care centre was evaluated. Inclusion criteria were all patients with severe TS who required surgical intervention. Exclusion criteria were patients with associated laryngeal stenosis and TS due to cancer. Demographic data was recorded and findings relating to aetiology, characteristics of stenosis and the various aspects of therapeutic procedures performed are discussed with review of literature. Descriptive analysis of data were performed SPSS 18. Results of the 20 patients, 17 patients (85 %) developed TS post tracheostomy, or post intubation and subsequent tracheostomy. 13 Patients (65 %) had true stenosis of which 7 patients (35 %) had simple web or circumferential fibrosis and 6 patients (30 %) had complex stenosis. Seven patients (35 %) had granulations causing severe TS which were mostly suprastomal (5 patients), stomal (5 patients) and combined stomal and suprastomal (3 patients). The average length of stenosis was 3.57 cm (0.5-8 cm). Montgomery t tube insertion was a common procedure in 18 patients (90 %) pre or post intervention. Each patient underwent an average of 3.4 procedures during their course of treatment which included rigid bronchoscopy and mechanical debulking, Nd YAG laser, KTP laser, balloon dilatation and use of stents. Among the 7 patients with granulations 100 % successful decanulation was noted with endoscopic management whereas in 13 patients with true stenosis, 10 patients (76.9 %) required open surgical management (8 tracheal resection and anastomosis and 2 tracheoplasty) with 80 % successful decanulation, 2 patients (15.4 %) were treated

  19. Control of Cell Wall Extensibility during Pollen Tube Growth

    OpenAIRE

    Hepler, Peter K.; Rounds, Caleb M.; Winship, Lawrence J.

    2013-01-01

    Tip-growing pollen tubes achieve rapid elongation while maintaining cell wall integrity by balancing local expansion, controlled by local changes in wall viscosity, against exocytosis, influenced by the activity of the actin cytoskeleton, cellular energetics, and calcium and proton physiology.

  20. Effects of α-particle radiation on rat tracheal epithelial cells

    International Nuclear Information System (INIS)

    Ford, J.R. Jr.

    1992-08-01

    By a combination of methods, which included flow cytometry and magnetic cell sorting, we have demonstrated that the cells of the rat tracheal epithelium which have the greatest proliferative capacity in culture and in vivo are the basal cells. Because of these findings it seems reasonable to suppose that the basal cells are the most likely target for the action of α-particle radiation in pseudostratified respiratory epithelium. This hypothesis is further supported by the finding that the basal cells are the cells which appear to respond to the tumor promoter 12-O-tetradecanoylphorbol-13-acetate. The effects of 210 Po α-particles on the survival and oncogenic transformation of rat tracheal epithelial cells in suspension were investigated. Since these effects were assayed in culture, the results pertain to the reaction of only the basal cells to irradiation. The results indicate that α-particles are extremely cytotoxic in that a track segment of 4 μm, on average, is sufficient to cause the reproductive death of basal cells. This finding is supported by similar results obtained with two cell lines, Mv1Lu and CHO-K1 BH 4 . Production of proliferating epithelial foci by α-particles was not distinguishable from control and sham treatments. These results are in direct conflict with many of the results that have been obtained with C3H 1OT1/2 cells in similar transformation assays. Some possible reasons for these disparities are discussed and supporting evidence is provided

  1. Acquired tracheoesophageal fistula due to high intracuff pressure

    Directory of Open Access Journals (Sweden)

    Hameed Akmal

    2008-01-01

    Full Text Available High-compliance endotracheal tube cuffs are used to prevent gas leak and also pulmonary aspiration in mechanically ventilated patients. However, the use of the usual cuff inflation volumes may cause tracheal damage and lead to tracheoesophageal fistula. Tracheostomy tube cuffs seal against the tracheal wall and prevent leakage of air around the tube, assuring that the tidal volume is delivered to the lungs. In the past, high-pressure cuffs were used, but these contributed to tracheal injury and have been replaced by high-volume, low-pressure cuffs. For long-term applications, some newer tubes have low-profile (tight to shaft cuffs that facilitate the tracheostomy tube changes by eliminating the lip that forms when standard cuffs are deflated.

  2. Learning From Experience: Improving Early Tracheal Extubation Success After Congenital Cardiac Surgery.

    Science.gov (United States)

    Winch, Peter D; Staudt, Anna M; Sebastian, Roby; Corridore, Marco; Tumin, Dmitry; Simsic, Janet; Galantowicz, Mark; Naguib, Aymen; Tobias, Joseph D

    2016-07-01

    The many advantages of early tracheal extubation following congenital cardiac surgery in young infants and children are now widely recognized. Benefits include avoiding the morbidity associated with prolonged intubation and the consequences of sedation and positive pressure ventilation in the setting of altered cardiopulmonary physiology. Our practice of tracheal extubation of young infants in the operating room following cardiac surgery has evolved and new challenges in the arena of postoperative sedation and pain management have appeared. Review our institutional outcomes associated with early tracheal extubation following congenital cardiac surgery. Inclusion criteria included all children less than 1 year old who underwent congenital cardiac surgery between October 1, 2010, and October 24, 2013. A total of 416 patients less than 1 year old were included. Of the 416 patients, 234 underwent tracheal extubation in the operating room (56%) with 25 requiring reintubation (10.7%), either immediately or following admission to the cardiothoracic ICU. Of the 25 patients extubated in the operating room who required reintubation, 22 failed within 24 hours of cardiothoracic ICU admission; 10 failures were directly related to narcotic doses that resulted in respiratory depression. As a result of this review, we have instituted changes in our cardiothoracic ICU postoperative care plans. We have developed a neonatal delirium score, and have adopted the "Kangaroo Care" approach that was first popularized in neonatal ICUs. This provision allows for the early parental holding of infants following admission to the cardiothoracic ICU and allows for appropriately selected parents to sleep in the same beds alongside their postoperative children.

  3. Association between pathogens from tracheal aspirate and oral biofilm of patients on mechanical ventilation.

    Science.gov (United States)

    Souza, Luana Carneiro Diniz; Mota, Vanise Barros Rodrigues da; Carvalho, Alícia Valéria Dos Santos Zaranza de; Corrêa, Rita da Graça Carvalhal Frazão; Libério, Silvana Amado; Lopes, Fernanda Ferreira

    2017-06-05

    The aim of this study was to detect possible associations between respiratory pathogens from tracheal aspirate and oral biofilm samples in intubated patients in an intensive care unit (ICU), and to identify the most common respiratory pathogens in oral biofilm, particularly in patients that developed ventilator-associated pneumonia (VAP). Two oral biofilm samples were collected from the tongue of intubated patients (at admission and after 48 hours) and analyzed by culture with the Antibiotic Sensitivity Test. The results from the tongue biofilm samples were compared with the tracheal secretions samples. A total of 59.37% of patients exhibited the same species of pathogens in their tracheal aspirate and oral biofilm, of which 8 (42.1%) developed VAP, 10 (52.63%) did not develop pneumonia and one (5.26%) had aspiration pneumonia. There was a statistically significant association between presence of microorganisms in the tracheal and mouth samples for the following pathogens: Klebsiella pneumoniae, Candida albicans, Pseudomonas aeruginosa, Enterobacter gergoviae, Streptococcus spp and Serratia marcescens (p aspirates of intubated patients can be detected in their oral cavity, especially in those who developed VAP or aspiration pneumonia. Thus, the results indicate that an improved oral care in these patients could decrease ICU pneumonia rates.

  4. Rac1 controls epithelial tube length through the apical secretion and polarity pathways

    Directory of Open Access Journals (Sweden)

    Kévin Sollier

    2016-01-01

    Full Text Available The morphometric parameters of epithelial tubes are critical to the physiology and homeostasis of most organs. In addition, many human diseases are associated with tube-size defects. Here, we show that Rac1 limits epithelial tube elongation in the developing fly trachea by promoting Rab5-dependent endocytosis of the apical determinant Crumbs. Rac1 is also involved in a positive feedback loop with the septate junction protein Coracle. Thereby, Rac1 precludes paracellular diffusion and contributes to the septate junction-dependent secretion of the chitin-modifying enzymes Vermiform and Serpentine, which restrict epithelial tube length independently of Crumbs. Thus, Rac1 is a critical component of two important pathways controlling epithelial tube morphogenesis.

  5. Nut tightening and bolt tension measuring apparatus for control guide tube with ultrasonic probe

    International Nuclear Information System (INIS)

    Lanzoni, M.

    1985-01-01

    Control rods are guided by elements set in the prolongation of the fuel assembly guide-tubes in which the control rods are introduced. These elements are inside guide-tubes fixed on the upper plate of the core by means of pins having a thread on which a nut is screwed bearing on the foot of the guide-tube. The pin is fixed inside the upper core plate by means of its lower part. An insufficient mechanical resistance and even failures have been observed with these pins. These failures have been involved by an unadequate screwing. The present invention proposes to control the pretension during the operation itself with an ultrasonic test [fr

  6. Changes in Tracheostomy- and Intubation-Related Tracheal Stenosis: Implications for Surgery.

    Science.gov (United States)

    Kim, Samuel S; Khalpey, Zain; Hsu, Charles; Little, Alex G

    2017-09-01

    This study sought to identify the changing characteristic patterns and locations of stenosis after tracheostomy or intubation and to assess the risk factors associated with perioperative complication and restenosis after primary resection and reconstruction. A retrospective review was performed (January /2012 to March 2015) on patients treated at the University of Arizona Medical Center (Tucson, Arizona) who had symptomatic tracheal stenosis secondary to prolonged intubation or tracheostomy. Data on demographics, surgical approach, and outcome were obtained. Analysis was performed using the χ 2 test, Kaplan-Meier estimate of survival, Cox proportional hazards survival analysis, and univariate and multivariate logistic regression. Forty-eight patients were referred for surgical resection, and 36 patients underwent primary resection and reconstruction; 72% of patients had previous endobronchial treatments for stenosis. Fourteen patients had postintubation tracheal stenosis, and 22 had tracheostomy-related stenosis (16 percutaneous, 6 open tracheostomy). Among all patients, 52.8% had stenosis proximal to or involving the cricoid; 72.7% of patients with tracheostomy-related stenosis had stenosis at or proximal to the cricoid, whereas only 21.4% of the patients with intubation-related stenosis had a similar location. Nineteen patients underwent laryngotracheal resection, and 17 patients had tracheal resection. The mean length of resection was 3.6 cm. A body mass index greater than 35 was associated with increased perioperative complications (p = 0.012). In multivariate analysis, patients younger than 30 years of age at operation had an increased relative risk of recurrence. Recent advances in percutaneous tracheostomy have increased the numbers of patients presenting with proximal tracheal stenosis, thus necessitating more complex subglottic resection and reconstruction. The anastomotic and overall complication rate remains low despite these more complex operations

  7. Cutting of Control Rod Guide Tubes and Jet Pumps at Wuergassen NPP/ Germany

    International Nuclear Information System (INIS)

    Ralf Loock

    2006-01-01

    KWW Nuclear Power Plant has been erected and put into operation in the time period 1968 to end of 1971. In 23 years of operation about 73 billions kWh electric power have been generated. The electric rated power was 670 MW. In May 1995 the decommission was started for economical reasons, since April 1997 the demolition is in progress. In autumn 2003 FANP has been called upon to cut the Control Rod Guide Tubes and Jet Pumps. After a 10 months preparatory phase, cutting of the Control Rod Guide Tubes and Jet Pumps was started in September 2004. For radiation protection reasons the Control Rod Guide Tubes and Jet Pumps were cut and packed remote controlled under water. The cutting process had been selected particularly under consideration of radiation protection aspects. A combination of the technologies band sawing and nibbling was assigned for cutting of the Control Rod Guide Tubes and Jet Pumps. The band saw consists of a substructure and of a feed system installed on it. The feed system can be equipped with one or two band saws optionally. A turntable is integrated in the substructure. It is used to support the CRGT respectively the residual piece of the CRGT and to move it out of the cut position after finishing the cutting. After getting the agreement to the specification, the equipment has been designed and manufactured according to the specification preferences. After finishing the internal testing, the factory acceptance test as well as acceptance and functional tests of every facility were carried out. After cold testing being performed successfully, the cutting equipment was installed in the NPP and checked for operational safety additionally. Cutting of the Control Rod Guide Tubes and Jet Pumps has been carried out on two working places inside the fuel element storage pool. During the total project duration on site the processing has been supervised by the radiation protection staff permanently. As a result 110 Control Rod Guide Tubes and 18 Jet Pumps were

  8. The Eclipse system for surveying the guide tubes of control rod clusters

    International Nuclear Information System (INIS)

    Pace, Y.M.

    2008-01-01

    Eclipse is a new system developed by Areva to assess the wear of the guide tubes of control rod clusters. This system is based on the projection of a shadow on a light plan in order to record the profile and the internal diameter of a hollow tube. This system allows us to quantify the wear and it can be included in a program dedicated to monitor the wear and master its kinetics. This system has been validated on the guide tubes from the Ringhals units. (A.C.)

  9. Increase in tracheal investment with beetle size supports hypothesis of oxygen limitation on insect gigantism.

    Science.gov (United States)

    Kaiser, Alexander; Klok, C Jaco; Socha, John J; Lee, Wah-Keat; Quinlan, Michael C; Harrison, Jon F

    2007-08-07

    Recent studies have suggested that Paleozoic hyperoxia enabled animal gigantism, and the subsequent hypoxia drove a reduction in animal size. This evolutionary hypothesis depends on the argument that gas exchange in many invertebrates and skin-breathing vertebrates becomes compromised at large sizes because of distance effects on diffusion. In contrast to vertebrates, which use respiratory and circulatory systems in series, gas exchange in insects is almost exclusively determined by the tracheal system, providing a particularly suitable model to investigate possible limitations of oxygen delivery on size. In this study, we used synchrotron x-ray phase-contrast imaging to visualize the tracheal system and quantify its dimensions in four species of darkling beetles varying in mass by 3 orders of magnitude. We document that, in striking contrast to the pattern observed in vertebrates, larger insects devote a greater fraction of their body to the respiratory system, as tracheal volume scaled with mass1.29. The trend is greatest in the legs; the cross-sectional area of the trachea penetrating the leg orifice scaled with mass1.02, whereas the cross-sectional area of the leg orifice scaled with mass0.77. These trends suggest the space available for tracheae within the leg may ultimately limit the maximum size of extant beetles. Because the size of the tracheal system can be reduced when oxygen supply is increased, hyperoxia, as occurred during late Carboniferous and early Permian, may have facilitated the evolution of giant insects by allowing limbs to reach larger sizes before the tracheal system became limited by spatial constraints.

  10. In vitro pharmacokinetics of sirolimus-coated stent for tracheal stenosis

    African Journals Online (AJOL)

    Further increases in sirolimus: PLGA ratio did not improve stent drug loading. A slow release of ... tracheal stent can damage the airway mucosa, and cause .... Figure 3: Cumulative drug release from sirolimus-coated stents. DISCUSSION.

  11. Aspergillus Tracheobronchitis Causing Subtotal Tracheal Stenosis in a Liver Transplant Recipient

    Directory of Open Access Journals (Sweden)

    Sonia Radunz

    2013-01-01

    Full Text Available Invasive aspergillosis is recognized as one of the most significant opportunistic infections after liver transplantation. Diagnosis of invasive aspergillosis in transplant recipients has been proven to be challenging, and optimal approach to the treatment of invasive aspergillosis is still controversial. We here present an unusual case of Aspergillus tracheobronchitis in the setting of liver transplantation. A 47-year-old female patient with persistent dry cough after liver transplantation developed respiratory insufficiency and was readmitted to the intensive care unit 55 days after liver transplantation. A CT scan revealed subtotal tracheal stenosis; bronchoscopy was performed, and extended white mucus coverings causative of the tracheal stenosis were removed. Microbiological assessment isolated Aspergillus fumigatus. The diagnosis was obstructive Aspergillus tracheobronchitis. The patient was started on a treatment of voriconazole 200 mg orally twice daily, adjusted to a trough level of 1–4 mg/L. For further airway management, a tracheal stent had to be implanted. The patient is alive and well 28 months after liver transplantation. Invasive aspergillosis should be considered a possible etiology in liver transplant patients presenting with unspecific symptoms such as persistent dry cough. Optimal strategies for improved and early diagnosis as well as prophylaxis need to be defined.

  12. Treatment of tracheal mucoepidermoid carcinoma by argon plasma coagulation during pregnancy.

    Science.gov (United States)

    Kesrouani, Assaad; Dabar, Georges; Rahal, Samir; Ghorra, Claude

    2015-05-01

    Mucoepidermoid carcinoma of the tracheobronchial tree is a rare airway tumor (cesarean section. We report the first case to be treated by Argon-Plasma Coagulation (APC) in pregnancy. A 35-year-old Caucasian woman G1P0, at 27 weeks of gestation was admitted to the emergency department because of hemoptysis and severe dyspnea. Bronchoscopy and biopsies diagnosed primary tracheal mucoepidermoid carcinoma. Following an episode of tracheal bleeding, she was intubated. After thorough explanations to the family and obtaining informed consent, therapeutic bronchoscopy, under general anesthesia using a rigid bronchoscope, was performed. The tumor was cored out with the tip of the bronchoscope and removed with an alligator forceps. The tumor bed was coagulated with APC. The obstetrical team was ready to intervene in case of maternal emergency. Immediate follow-up was good, and she left the hospital 4 days later. She delivered at 39 weeks of gestation by cesarean section because of dystocia. Five years later, the patient is doing well without any signs or symptoms of recurrence. Pediatric follow-up is normal. Argon Plasma Coagulation for treatment of mucoepidermoid tracheal carcinoma is feasible during pregnancy. Reporting this case could lead to less aggressive management of mucoepidermoid carcinoma in pregnant patients.

  13. Humidity Control System In The Neutron Detector Of Guide Tube

    International Nuclear Information System (INIS)

    Alibasya Harahap, Sentot

    2001-01-01

    The probable symptom neutron detector damage as cause decrease resistivity and corrosion in the electrical terminal, further more occasion to voltage failure and leak current in the isolation. The prevent of voltage failure in detector a needed humidity controller's with dry air supply to guide tube with 2 kg/cm exp.2 air pressure and 7 l/min, air flow as soon as continuity dryer process in the guide tube. Reactor shutdown and operation condition of diffusion rate is 0,476 cm exp.3/year and 6,46 cm exp.3/year

  14. Prematurity and fetal lung response after tracheal occlusion in fetuses with severe congenital diaphragmatic hernia.

    Science.gov (United States)

    Sananes, Nicolas; Rodo, Carlota; Peiro, Jose Luis; Britto, Ingrid Schwach Werneck; Sangi-Haghpeykar, Haleh; Favre, Romain; Joal, Arnaud; Gaudineau, Adrien; Silva, Marcos Marques da; Tannuri, Uenis; Zugaib, Marcelo; Carreras, Elena; Ruano, Rodrigo

    2016-09-01

    To evaluate the independent association of fetal pulmonary response and prematurity to postnatal outcomes after fetal tracheal occlusion for congenital diaphragmatic hernia. Fetal pulmonary response, prematurity (prematurity (prematurity was not statistically associated with mortality after controlling for fetal pulmonary response (aOR 0.52, 95% CI 0.12-2.30, p=0.367). Fetal pulmonary response after FETO is the most important factor associated with survival, independently from the gestational age at delivery.

  15. Effect of just-in-time simulation training on tracheal intubation procedure safety in the pediatric intensive care unit.

    Science.gov (United States)

    Nishisaki, Akira; Donoghue, Aaron J; Colborn, Shawn; Watson, Christine; Meyer, Andrew; Brown, Calvin A; Helfaer, Mark A; Walls, Ron M; Nadkarni, Vinay M

    2010-07-01

    Tracheal intubation-associated events (TIAEs) are common (20%) and life threatening (4%) in pediatric intensive care units. Physician trainees are required to learn tracheal intubation during intensive care unit rotations. The authors hypothesized that "just-in-time" simulation-based intubation refresher training would improve resident participation, success, and decrease TIAEs. For 14 months, one of two on-call residents, nurses, and respiratory therapists received 20-min multidisciplinary simulation-based tracheal intubation training and 10-min resident skill refresher training at the beginning of their on-call period in addition to routine residency education. The rate of first attempt and overall success between refresher-trained and concurrent non-refresher-trained residents (controls) during the intervention phase was compared. The incidence of TIAEs between preintervention and intervention phase was also compared. Four hundred one consecutive primary orotracheal intubations were evaluated: 220 preintervention and 181 intervention. During intervention phase, neither first-attempt success nor overall success rate differed between refresher-trained residents versus concurrent non-refresher-trained residents: 20 of 40 (50%) versus 15 of 24 (62.5%), P = 0.44 and 23 of 40 (57.5%) versus 18 of 24 (75.0%), P = 0.19, respectively. The resident's first attempt and overall success rate did not differ between preintervention and intervention phases. The incidence of TIAE during preintervention and intervention phases was similar: 22.0% preintervention versus 19.9% intervention, P = 0.62, whereas resident participation increased from 20.9% preintervention to 35.4% intervention, P = 0.002. Resident participation continued to be associated with TIAE even after adjusting for the phase and difficult airway condition: odds ratio 2.22 (95% CI 1.28-3.87, P = 0.005). Brief just-in-time multidisciplinary simulation-based intubation refresher training did not improve the resident

  16. Efficacy of transoral intraluminal Wallstents for tracheal stenosis or tracheomalacia.

    Science.gov (United States)

    Casiano, R R; Numa, W A; Nurko, Y J

    2000-10-01

    The efficacy and safety of intraluminal Wallstent Endoprosthesis (Boston Scientific/ Medi-Tech, Quincy, MA) placement to restore airway patency in patients with tracheal stenosis or tracheomalacia are unknown. Retrospective review in setting of tertiary, referral, and academic center. A retrospective review of 13 consecutive patients over a 2-year period who underwent transoral resection of tracheal stenosis and immediate transoral Wallstent placement. One patient had tracheomalacia. All of the patients were considered at high risk for transcervical surgery or had failed prior traditional open procedures. The average patient age was 54.2 years, with nine male and four female patients. All had Cotton/Myer stenoses (grades II to IV) with moderate to severe degrees of inspiratory stridor. Four patients were tracheotomy dependent. The length of stenosis varied from 1 to 4 cm. One patient had a 10-cm segment of tracheomalacia. At the time of writing, none of the patients has had a problem with significant migration or extrusion and most of the patients have incorporated the stent well without any short-term obstructive granulation tissue. After a mean follow-up of 15 months (range, 4-24 mo). 10 of the 12 patients with stenosis (83%) have remained free of any inspiratory noise during breathing. The one patient with tracheomalacia also has remained free of symptoms. Transoral Wallstents appear to be safe and may be a reasonable alternative in the restoration of airway patency in select patients with tracheal stenosis or tracheomalacia.

  17. Bradykinin B2 receptor-mediated phosphoinositide hydrolysis in bovine cultured tracheal smooth muscle cells.

    OpenAIRE

    Marsh, K. A.; Hill, S. J.

    1992-01-01

    1. Bovine tracheal smooth muscle cells were established in culture to study agonist-induced phosphoinositide (PI) hydrolysis in this tissue. 2. Bradykinin (0.1 nM-10 microM) evoked a concentration-dependent increase (log EC50 (M) = -9.4 +/- 0.2; n = 8) in the accumulation of total [3H]-inositol phosphates in cultured tracheal smooth muscle cells whereas the selective B1 receptor agonist des-Arg9-bradykinin (10 microM) was significantly less effective (16% of bradykinin maximal response; relat...

  18. Evidence that CFTR is expressed in rat tracheal smooth muscle cells and contributes to bronchodilation

    Directory of Open Access Journals (Sweden)

    Mettey Yvette

    2006-08-01

    Full Text Available Abstract Background The airway functions are profoundly affected in many diseases including asthma, chronic obstructive pulmonary disease (COPD and cystic fibrosis (CF. CF the most common lethal autosomal recessive genetic disease is caused by mutations of the CFTR gene, which normally encodes a multifunctional and integral membrane protein, the CF transmembrane conductance regulator (CFTR expressed in airway epithelial cells. Methods To demonstrate that CFTR is also expressed in tracheal smooth muscle cells (TSMC, we used iodide efflux assay to analyse the chloride transports in organ culture of rat TSMC, immunofluorescence study to localize CFTR proteins and isometric contraction measurement on isolated tracheal rings to observe the implication of CFTR in the bronchodilation. Results We characterized three different pathways stimulated by the cAMP agonist forskolin and the isoflavone agent genistein, by the calcium ionophore A23187 and by hypo-osmotic challenge. The pharmacology of the cAMP-dependent iodide efflux was investigated in detail. We demonstrated in rat TSMC that it is remarkably similar to that of the epithelial CFTR, both for activation (using three benzo [c]quinolizinium derivatives and for inhibition (glibenclamide, DPC and CFTRinh-172. Using rat tracheal rings, we observed that the activation of CFTR by benzoquinolizinium derivatives in TSMC leads to CFTRinh-172-sensitive bronchodilation after constriction with carbachol. An immunolocalisation study confirmed expression of CFTR in tracheal myocytes. Conclusion Altogether, these observations revealed that CFTR in the airways of rat is expressed not only in the epithelial cells but also in tracheal smooth muscle cells leading to the hypothesis that this ionic channel could contribute to bronchodilation.

  19. Equine tracheal epithelial membrane strips - An alternate method for examining epithelial cell arachidonic acid metabolism

    International Nuclear Information System (INIS)

    Gray, P.R.; Derksen, F.J.; Robinson, N.E.; Peter-Golden, M.L.

    1990-01-01

    Arachidonic acid metabolism by tracheal epithelium can be studied using enzymatically dispersed cell suspensions or cell cultures. Both techniques require considerable tissue disruption and manipulation and may not accurately represent in vivo activity. The authors have developed an alternate method for obtaining strips of equine tracheal epithelium without enzymatic digestion. In the horse, a prominent elastic lamina supports the tracheal epithelium. By physical splitting this lamina, they obtained strips (≤12 x 1.5 cm) of pseudostratified columnar epithelium attached to a layer of elastic tissue 30-100 μm thick. Epithelial strips (1.2 x 0.5 cm) were attached to plexiglass rods and incubated with [ 3 H]arachidonic acid in M199 medium (0.5 μCi/ml) for 24 hours at 37C. The strips incorporated 36±4% (mean ± SEM) of the total radioactivity and released 8.0±1.2% of incorporated radioactivity when stimulated by 5.0 μM calcium ionophore A23187. The extracted supernatant was processed using HPLC, resulting in peaks of radioactivity that co-eluted with authentic PGE 2 , PGF 2 α, and 12-HETE standards. The greatest activity corresponded to the PGE 2 and PGF 2 α standards, which is a similar pattern to that reported for cultured human tracheal epithelium

  20. Design and fabrication of hafnium tube to control the power of the irradiation test fuel in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Lee, C. B.; Kim, Y. M.; Yang, Y. S.; Jung, Y. H

    2003-05-01

    For the irradiation test at HANARO, non-instrumentation capsule was manufactured and hafnium tube was used to control LHGR of HANARO. Hafnium tube can control the irradiation condition of HANARO similar to that of commercial reactor. Hafnium tube thickness was determined by the LHGR calculated at OR-4 irradiation hole to be installed the non-instrumented capsule. To fabricate the hafnium tube with hafnium plate, the fabrication method was determined by using the hafnium mechanical properties. And the tensile strength of hafnium was confirmed by tensile test. This report is confirmed the LHGR control at the OR-4 and the Hafnium fabrication for in used which the AFPCAP non-instrumented irradiation capsule.

  1. Eustachian tube patency

    Science.gov (United States)

    Eustachian tube patency refers to how much the eustachian tube is open. The eustachian tube runs between the middle ear and the throat. It controls the pressure behind the eardrum and middle ear space. This helps keep ...

  2. Ultrasonic testing of canning tubes in stainless steel of the EL 4 reactor; Controle par ultrasons des tubes de gaine en acier inoxydable du reacteur EL 4

    Energy Technology Data Exchange (ETDEWEB)

    Prot, A; Monnier, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    From all the methods possible for controlling thin cans the one chosen, for numerous reasons, vas that making use of ultrasonic techniques. A method has been developed which should make it possible to carry out a rapid and efficient industrial control of canning tubes, The reasons for the choice of the ultrasonic method are given in detail, together with the principles of the method and the actual control parameters. In the present state of our research, it should be possible to control at least 50 000 tubes a year. Improvements brought about in the details of the control technique itself should make it possible to increase this rate considerably. (authors) [French] Parmi toutes les methodes possibles de controle des gaines minces, le procede retenu pour de multiples raisons a ete celui faisant appel a la technique des ultrasons. Une methode a ete mise au point qui doit permettre un controle industriel rapide et efficace des tubes de gaine. Sont exposes en detail, les raisons du choix de la methode par ultrasons, les principes de cette methode et les parametres du controle proprement dit. Dans l'etat actuel de nos etudes la cadence devrait permettre le controle de 50000 tubes par an au minimum. Des ameliorations de detail portant sur la technique de controle elle-meme, doivent permettre d'accelerer tres notablement cette cadence. (auteurs)

  3. Experimental use of new absorbable tracheal stent.

    Science.gov (United States)

    Schopf, Luciano F; Fraga, José Carlos; Porto, Rodrigo; Santos, Luis A; Marques, Douglas R; Sanchez, Paulo R; Meyer, Fabíola S; Ulbrich, Jane M

    2017-11-16

    Silicone and metallic stents are not effective in children with tracheobronchial stenosis or tracheomalacia. Herein, we aimed to evaluate the clinical manifestations and histological reaction of rabbit trachea to the presence of a new poly(lactic-co-glycolic acid) with polyisoprene (PLGA/PI) polymer absorbable stent. Fourteen adult white rabbits (weight, 3.0-3.5kg) were randomly assigned to three groups: Group I (n=6): PLGA/PI spiral stent; Group II (n=6): PLGA/PI fragment; and Group III (n=2): controls. After a longitudinal incision on three cervical tracheal rings, the stents and fragments were inserted into the trachea and fixed onto the lateral wall with nonabsorbable sutures. The stented group showed significantly more stridor at rest (p=0.0041), agitation (p=0.014), and use of accessory muscles (p=0.0002) and required more emergency endoscopies than the fragment group. Further, it showed significantly more remarkable histological inflammatory damage than the fragment and control groups (p=0.002). The new PLGA/PI polymeric stent implanted into the trachea of rabbits caused more clinical manifestations and histologically verified inflammatory reaction than the PLGA/PI polymeric fragment. Future studies should be aimed at reducing the stent-wall thickness. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Tracheal and laryngeal tumors in the dog and cat: literature review and 13 additional patients

    International Nuclear Information System (INIS)

    Carlisle, C.H.; Biery, D.N.; Thrall, D.E.

    1991-01-01

    Primary tumors of the larynx or trachea are uncommon in the dog and cat. In a review of the English language literature, description of 65 such patients were found. In a search of the Veterinary Teaching Hospitals of the University of Pennsylvania and North Carolina State University, an additional 13 previously unreported patients were identified, bringing the total to at least 78. Of these 78, there have been 16 canine tracheal, 7 feline tracheal, 34 canine laryngeal and 21 feline laryngeal tumors. In the canine and feline trachea, osteochondroma and epithelial malignancies, respectively, appear to be the most common. Epithelial malignancies appear to be the most common tumor of the canine larynx whereas lymphosarcoma appears to be the most common feline laryngeal tumor. In patients described herein, tumors produced clinical signs consistent with airway obstruction. Voice alteration was common in patients with laryngeal tumors. Patients were middle-aged to older, except for dogs with osteochondroma. This compares favorably to historical data. All tumors in this study were readily seen radiographically, with most laryngeal and tracheal tumors appearing as masses within the lumen of the airway. Mineralization was uncommon except for canine osteochondromas. Feline laryngeal tumors in this study appeared as generalized laryngeal thickening rather than as a distinct mass. Response of canine and feline tracheal and laryngeal thickening rather than as a distinct mass. Response of canine and feline tracheal and laryngeal tumors to treatment can not be adequately assessed from available data. Benign tumors of the larynx or trachea may be amenable to complete excision. Neoplastic lesions must be differentiated from polyps or abscesses within the upper airway as these may appear radiographically identical to primary tumors. This can be achieved by endoscopic evaluation and biopsy of airway masses before formulating a prognosis

  5. Recurrent airway obstructions in a patient with benign tracheal stenosis and a silicone airway stent: a case report

    Science.gov (United States)

    Sriram, KB; Robinson, PC

    2008-01-01

    Airway stents (silicone and metal stents) are used to treat patients with benign tracheal stenosis, who are symptomatic and in whom tracheal surgical reconstruction has failed or is not appropriate. However airway stents are often associated with complications such as migration, granuloma formation and mucous hypersecretion, which cause significant morbidity, especially in patients with benign tracheal stenosis and relatively normal life expectancy. We report a patient who had frequent critical airway obstructions over 8 years due to granuloma and mucus hypersecretion in a silicone airway stent. The problem was resolved when the silicone stent was removed and replaced with a covered self expanding metal stent. PMID:18840299

  6. Immobilization of pseudorabies virus in porcine tracheal respiratory mucus revealed by single particle tracking.

    Directory of Open Access Journals (Sweden)

    Xiaoyun Yang

    Full Text Available Pseudorabies virus (PRV initially replicates in the porcine upper respiratory tract. It easily invades the mucosae and submucosae for subsequent spread throughout the body via blood vessels and nervous system. In this context, PRV developed ingenious processes to overcome different barriers such as epithelial cells and the basement membrane. Another important but often overlooked barrier is the substantial mucus layer which coats the mucosae. However, little is known about how PRV particles interact with porcine respiratory mucus. We therefore measured the barrier properties of porcine tracheal respiratory mucus, and investigated the mobility of nanoparticles including PRV in this mucus. We developed an in vitro model utilizing single particle tracking microscopy. Firstly, the mucus pore size was evaluated with polyethylene glycol coupled (PEGylated nanoparticles and atomic force microscope. Secondly, the mobility of PRV in porcine tracheal respiratory mucus was examined and compared with that of negative, positive and PEGylated nanoparticles. The pore size of porcine tracheal respiratory mucus ranged from 80 to 1500 nm, with an average diameter of 455±240 nm. PRV (zeta potential: -31.8±1.5 mV experienced a severe obstruction in porcine tracheal respiratory mucus, diffusing 59-fold more slowly than in water. Similarly, the highly negatively (-49.8±0.6 mV and positively (36.7±1.1 mV charged nanoparticles were significantly trapped. In contrast, the nearly neutral, hydrophilic PEGylated nanoparticles (-9.6±0.8 mV diffused rapidly, with the majority of particles moving 50-fold faster than PRV. The mobility of the particles measured was found to be related but not correlated to their surface charge. Furthermore, PEGylated PRV (-13.8±0.9 mV was observed to diffuse 13-fold faster than native PRV. These findings clearly show that the mobility of PRV was significantly hindered in porcine tracheal respiratory mucus, and that the obstruction of PRV

  7. Freezing controlled penetration of molten metals flowing through stainless steel tubes

    International Nuclear Information System (INIS)

    Sienicki, J.J.; Spencer, B.W.; Vetter, D.L.; Wesel, R.H.

    1985-01-01

    The freezing controlled penetration potential of molten metals flowing within stainless steel structure is important to the safety assessment of hypothetical severe accidents in liquid metal reactors. A series of scoping experiments has been performed in which molten stainless steel and nickel at various initial temperatures and driving pressures were injected downward and upward into 6.4 and 3.3 mm ID stainless steel tubes filled with argon gas and initially at room temperature. In all tests, there was no evidence that the solid tube wall was wetted by the molten metals. The penetration phenomena are markedly different for downward versus upward injections. The dependency upon tube orientation is explained in terms of the absence of wetting. Complete plugs were formed in all experiments halting the continued injection of melt. Calculations with a fluid dynamics/heat transfer computer code show that the injected masses limited by plugging are consistent with freezing through the growth of a stable solidified layer (crust) of metal upon the solid tube wall. 23 refs., 5 figs., 2 tabs

  8. Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats

    Directory of Open Access Journals (Sweden)

    Olavo Ribeiro Rodrigues

    2013-01-01

    Full Text Available PURPOSE: To investigate the compatibility of a new model of self-expandable tracheal stent in rats. METHODS: A new device of polyurethane covered and non - covered stent was placed in the trachea of Wistar rats. Animals were distributed in two groups: the polyurethane covered and non-covered group. Macroscopic parameters included position within the tracheal lumen, adherence to the mucosa, degree of dilatation, permeability and internal diameter. Microscopic findings evaluated were: incorporation, inflammatory activity, granulation tissue and epithelial revetment injuries. The observation follow-up was six weeks. All parameters were quantified based on determined score values. Incorporation of the stents was evaluated based on the observation if the stent was fixed into the trachea or if it could be removed. Degree of dilatation was performed by external diameter measurements. Granulation tissue was evaluated by measurements of height of the tissue growing into the tracheal lumen. RESULTS: 100% of non-covered stents had total attachment to mucosa and 100% of polyurethane covered type had adherence only. Regarding dilatation, granulation tissue, inflammatory activity and internal diameter measurements, there were no significant differences between the groups. Pathological tracheal wall injuries were present in both groups. CONCLUSION: Both models of stent demonstrated biocompatibility with the trachea. Rats are suitable for an experimental model of tracheal stent study.

  9. Beta2-adrenoceptor-mediated tracheal relaxation induced by higenamine from Nandina domestica Thunberg.

    Science.gov (United States)

    Tsukiyama, Muneo; Ueki, Takuro; Yasuda, Yoichi; Kikuchi, Hiroko; Akaishi, Tatsuhiro; Okumura, Hidenobu; Abe, Kazuho

    2009-10-01

    The fruit of Nandina domestica Thunberg (ND, Berberidaceae) has been used to improve cough and breathing difficulties in Japan for many years, but very little is known about the constituent of ND responsible for this effect. We have recently reported that the crude extract from ND (NDE) inhibits histamine- and serotonin-induced contraction of isolated guinea pig trachea, and the inhibitory activity was not explained by nantenine, a well-known alkaloid isolated from ND. To explore other constituent(s) of NDE with tracheal smooth muscle relaxant activity, we fractionated NDE and assessed the pharmacological effects of the fractions using isolated guinea pig tracheal ring preparations. NDE was introduced into a polyaromatic absorbent resin column and stepwise eluted to yield five fractions, among which only the 40 % methanol fraction was active in relaxing tracheal smooth muscle precontracted with histamine. Further separation of the 40 % methanol fraction with high-performance liquid chromatography yielded multiple subfractions, one of which was remarkably active in relaxing histamine-precontracted trachea. Chemical analysis with a time-of-flight mass spectrometer and nuclear magnetic resonance spectrometer identified the constituent of the most active subfraction as higenamine, a benzyltetrahydroisoquinoline alkaloid. The potency and efficacy of the active constituent from NDE in relaxing trachea were almost equivalent to synthetic higenamine. In addition, the effect of the active constituent from NDE was competitively inhibited by the selective beta (2)-adrenoceptor antagonist ICI 118,551. These results indicate that the major constituent responsible for the effect of NDE is higenamine, which probably causes the tracheal relaxation through stimulation of beta (2) adrenoceptors. Georg Thieme Verlag KG Stuttgart-New York.

  10. Modelling of the ultrasonic inspection of steel tubes with longitudinal defects; Modelisation du controle ultrasonore de tubes d`acier presentant des defauts de type ``entaille longitudinale``

    Energy Technology Data Exchange (ETDEWEB)

    Mephane, M

    1998-12-31

    A model has been developed in order to simulate the ultrasonic inspection of steel tubes in the Vallourec control configuration. The model permits to simulate the control of steel tubes showing longitudinal defects located near the internal or external surface of tubes which appear during the rolling process. To detect this kind of defect, the probe is placed in an incident place perpendicular to the tube`s axis. The probe is in front of the external surface of the tube. The main characteristics of the model is to assume that the field radiated in the material does not depend on the probe`s position. This assumption permits to treat separately the field retracted in the material and the interaction between the defect and the ultrasonic beam. The focal plane is located in the material, so the plane waves approximation is applied where the waves front are assumed plane and parallel. The parallel refracted beam becomes divergent after reflection on the internal surface of tube. To treat the beam divergence, an amplitude weighting coefficient is then calculated by mean of the energy conservation of a tube of rays before and after reflection, following the Snell laws. This model can predict the edge diffraction echoes, the echoes issued from the corner effect, and also the mode conversion echoes. It has been validated on artificial notches, and on some natural defects. A comparison between experimental and modelling results shows a good agreement. (author) 39 refs.

  11. Study of scratch-induced stress corrosion cracking for steam generator tubes and scratch control

    International Nuclear Information System (INIS)

    Meng, F.; Xu, X.; Liu, X.; Wang, J.

    2014-01-01

    This paper introduces field cases for scratch-induced stress corrosion cracking (SISCC) of steam generator tubes in PWR and current studies in laboratories. According to analysis result of broke tubes, scratches caused intergranular stress corrosion cracking (IGSCC) with outburst. The effect of microstructure for nickel-base alloys, residual stresses caused by scratching process and water chemistry on SISCC and possible mechanism of SISCC are discussed. The result shows that scratch-induced microstructure evolution contributes to SISCC significantly. The causes of scratches during steam generator tubing manufacturing and installation process are stated and improved reliability with scratch control is highlighted for steam generator tubes in newly built nuclear power plants. (author)

  12. Study of scratch-induced stress corrosion cracking for steam generator tubes and scratch control

    Energy Technology Data Exchange (ETDEWEB)

    Meng, F.; Xu, X.; Liu, X. [Shanghai Nuclear Engineering Research and Design Institute, Shanghai (China); Wang, J. [Chinese Academy of Sciences, Institute of Metal Research, Shenyang (China)

    2014-07-01

    This paper introduces field cases for scratch-induced stress corrosion cracking (SISCC) of steam generator tubes in PWR and current studies in laboratories. According to analysis result of broke tubes, scratches caused intergranular stress corrosion cracking (IGSCC) with outburst. The effect of microstructure for nickel-base alloys, residual stresses caused by scratching process and water chemistry on SISCC and possible mechanism of SISCC are discussed. The result shows that scratch-induced microstructure evolution contributes to SISCC significantly. The causes of scratches during steam generator tubing manufacturing and installation process are stated and improved reliability with scratch control is highlighted for steam generator tubes in newly built nuclear power plants. (author)

  13. Evaluation of friction forces between control bars and guide tubes of CAREM fuel element

    International Nuclear Information System (INIS)

    Ghiselli, Alberto M.; Fiori, Jose M.; Yedros, Pablo A.

    2003-01-01

    The design of the MSAC (Mecanismo del Sistema de ajuste y control, Mechanism of the Adjustment and control system, MACS) for CAREM reactor shall consider all loads that the reactor shall support during its operation. Several charges are originated by friction forces produced on contact points of the control Bars/Guide tubes assembly against other components. A test facility was designed and manufactured for the determination of friction components and the damping characteristics of the assembly formed by guide tubes fuel element, the control bars and the guide of the bar of the MACS. In this work a description of the test performed and the results obtained is presented. (author)

  14. Influence of structure improvement of guide tubes and bundles in pressurized water reactor (PWR) on drop of control rods

    International Nuclear Information System (INIS)

    Shen Xiuzhong; Yu Pingan; Yang Guanyue

    1996-01-01

    In order to alleviate the cross hydraulic load on control rod guide tubes and bundles, some protective sleeves are added to those near the upper plenum outlet nozzles (4 symmetric bundles: 02-26, 03-25, 11-29, 12-28). In a 1/4 scale transparent model of the PWR upper plenum of Qinshan Nuclear Power Station, water was chosen as the fluid and hydraulic experiments with improved control rod guide tubes and bundles were carried out. The results were carefully compared with those of the experiments with unimproved control rod guide tubes and bundles. It is concluded that adding protective sleeves to the control rod guide tubes and bundles near the outlet nozzles will help to lighten the hydraulic load on them and make certain of the free movement and rapid dropping of control rods in the tubes and bundles in emergency by order

  15. Robust Output Model Predictive Control of an Unstable Rijke Tube

    Directory of Open Access Journals (Sweden)

    Fabian Jarmolowitz

    2012-01-01

    Full Text Available This work investigates the active control of an unstable Rijke tube using robust output model predictive control (RMPC. As internal model a polytopic linear system with constraints is assumed to account for uncertainties. For guaranteed stability, a linear state feedback controller is designed using linear matrix inequalities and used within a feedback formulation of the model predictive controller. For state estimation a robust gain-scheduled observer is developed. It is shown that the proposed RMPC ensures robust stability under constraints over the considered operating range.

  16. Ho:YAG laser in reshaping tracheal cartilage: a pilot investigation using ex vivo porcine and rabbit cartilage

    Science.gov (United States)

    Lam, Anthony; Protsenko, Dmitry E.; Carbone, Nicholas; Li, Chao; Jackson, Ryan; Wong, Brian J.

    2004-07-01

    Stenotic, collapsed, and flow-restricted tracheal airways may result from blunt trauma, chronic infection, and the prolonged endotracheal intubation. This pilot investigation characterizes the degree of shape change produced by Ho:YAG laser (λ=2.12 μm) irradiation of rabbit and pig trachea tissue as a function of laser dosimetry and application protocol. Force displacement curves were generated using fresh lagomorph and porcine tracheal cartilage rings secured in a modified single beam cantilever geometry. These specimens were then irradiated for varying amounts of time and power with the objective of straightening these curved specimens. The degree of shape change was documented photographically. Force and surface temperature were monitored. Confocal microscopy was then used in combination a vital staine ("live-dead assay") to determine the level of viability of straightened cartilage for selected exposure time-power pairs. Laser Cartilage Reshaping of the trachea may provide a new method to treat severe tracheal injuries without the need for classic open surgical techniques. This pilot investigation is the first step toward demonstrating the feasibility of this technique. Long-term, the design of stents combined with laser irradiation may provide a means to alter tracheal shape.

  17. Biodegradable SX-ELLA tracheal stent as a new minimally invasive solution for severe tracheomalacia in newborns

    OpenAIRE

    Sztanó, B; Rácz, G; Szegesdi, I; Rovó, L

    2015-01-01

    Introduction: The solution of severe tracheomalacia in early childhood means a great challenge even nowadays. The dyspnea often requires an immediate surgical investigation. Unfortunately, tracheal segmentresection and replacement of the tracheal wall, which methods are widely used in adults, are really hard to be performed at this age because of the patients' small size. The babies' tissues are so thin and mild, so the application of classical airway stents has a high risk of intrathoracal ...

  18. Self-propelled in-tube shuttle and control system for automated measurements of magnetic field alignment

    International Nuclear Information System (INIS)

    Boroski, W.N.; Nicol, T.H.; Pidcoe, S.V.

    1990-03-01

    A magnetic field alignment gauge is used to measure the field angle as a function of axial position in each of the magnets for the Superconducting Super Collider (SSC). Present measurements are made by manually pushing the through the magnet bore tube and stopping at intervals to record field measurements. Gauge location is controlled through graduation marks and alignment pins on the push rods. Field measurements are recorded on a logging multimeter with tape output. Described is a computerized control system being developed to replace the manual procedure for field alignment measurements. The automated system employs a pneumatic walking device to move the measurement gauge through the bore tube. Movement of the device, called the Self-Propelled In-Tube Shuttle (SPITS), is accomplished through an integral, gas driven, double-acting cylinder. The motion of the SPITS is transferred to the bore tube by means of a pair of controlled, retractable support feet. Control of the SPITS is accomplished through an RS-422 interface from an IBM-compatible computer to a series of solenoid-actuated air valves. Direction of SPITS travel is determined by the air-valve sequence, and is managed through the control software. Precise axial position of the gauge within the magnet is returned to the control system through an optically-encoded digital position transducer attached to the shuttle. Discussed is the performance of the transport device and control system during preliminary testing of the first prototype shuttle. 1 ref., 7 figs

  19. Support vector regression model based predictive control of water level of U-tube steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Kavaklioglu, Kadir, E-mail: kadir.kavaklioglu@pau.edu.tr

    2014-10-15

    Highlights: • Water level of U-tube steam generators was controlled in a model predictive fashion. • Models for steam generator water level were built using support vector regression. • Cost function minimization for future optimal controls was performed by using the steepest descent method. • The results indicated the feasibility of the proposed method. - Abstract: A predictive control algorithm using support vector regression based models was proposed for controlling the water level of U-tube steam generators of pressurized water reactors. Steam generator data were obtained using a transfer function model of U-tube steam generators. Support vector regression based models were built using a time series type model structure for five different operating powers. Feedwater flow controls were calculated by minimizing a cost function that includes the level error, the feedwater change and the mismatch between feedwater and steam flow rates. Proposed algorithm was applied for a scenario consisting of a level setpoint change and a steam flow disturbance. The results showed that steam generator level can be controlled at all powers effectively by the proposed method.

  20. Pilot Study Comparing Closed Versus Open Tracheal Suctioning in Postoperative Neonates and Infants With Complex Congenital Heart Disease.

    Science.gov (United States)

    Tume, Lyvonne N; Baines, Paul B; Guerrero, Rafael; Hurley, Margaret A; Johnson, Robert; Kalantre, Atul; Ramaraj, Ram; Ritson, Paul C; Walsh, Laura; Arnold, Philip D

    2017-07-01

    To determine the hemodynamic effect of tracheal suction method in the first 36 hours after high-risk infant heart surgery on the PICU and to compare open and closed suctioning techniques. Pilot randomized crossover study. Single PICU in United Kingdom. Infants undergoing surgical palliation with Norwood Sano, modified Blalock-Taussig shunt, or pulmonary artery banding in the first 36 hours postoperatively. Infants were randomized to receive open or closed (in-line) tracheal suctioning either for their first or second study tracheal suction in the first 36 hours postoperatively. Twenty-four infants were enrolled over 18 months, 11 after modified Blalock-Taussig shunt, seven after Norwood Sano, and six after pulmonary artery banding. Thirteen patients received the open suction method first followed by the closed suction method second, and 11 patients received the closed suction method first followed by the open suction method second in the first 36 hours after their surgery. There were statistically significant larger changes in heart rate (p = 0.002), systolic blood pressure (p = 0.022), diastolic blood pressure (p = 0.009), mean blood pressure (p = 0.007), and arterial saturation (p = 0.040) using the open suction method, compared with closed suctioning, although none were clinically significant (defined as requiring any intervention). There were no clinically significant differences between closed and open tracheal suction methods; however, there were statistically significant greater changes in some hemodynamic variables with open tracheal suctioning, suggesting that closed technique may be safer in children with more precarious physiology.

  1. Tracheal collapse diagnosed by multidetector computed tomography: evaluation of different image analysis methods

    DEFF Research Database (Denmark)

    Nygaard, Mette; Bendstrup, Elisabeth; Dahl, Ronald

    2017-01-01

    diseases when using an expiratory collapse of = 50% as a threshold. The four methods were comparable with highly significant Pearsons correlation coefficients (0.764-0.856). However, the four methods identified different patients with collapse of = 50 There was no correlation between symptoms...... and the degree of collapse. Conclusion: The different methods identify tracheal collapse in different patients. Hence, the diagnosis of excessive tracheal collapse can not rely solely on MDCT images. Generally, there is a poor correlation between symptoms and the degree of collapse in the different methods....... However, when using the maximal collapse, there is some correlation with symptoms. When in doubt regarding the diagnosis, further investigations, such as bronchoscopy, should be carried out....

  2. [Unexpected treatable dyspnea caused by intratracheal granuloma in an amyotrophic lateral sclerosis patient with mechanical ventilation].

    Science.gov (United States)

    Ishida, Shimon; Kimura, Fumiharu; Hosokawa, Takafumi; Satoh, Toshihiko; Furutama, Daisuke; Sugino, Masakazu

    2007-09-01

    Respiratory insufficiency is a problem that develops in nearly all people diagnosed with amyotrophic lateral sclerosis (ALS). A 46-year-old man with ALS, who had been in a bedridden state with tracheal ventilation support, complained of faintness and dyspnea. The airway pressure of the ventilator had increased, and bleeding from the trachea had occurred several times. A fiberoptic bronchoscopy showed granulation located on the anterior wall of the trachea and severe airway obstruction of the tracheostomy tube. Although a long tracheostomy tube had been intubated for the initial management of the tracheal granulation, a tumor on the posterior tracheal wall had relapsed and occluded the tracheal lumen. A self-expandable metallic airway stent was placed into the tracheal stenosis. After stenting, his symptoms of dyspnea and syncope imploved, and the increased airway pressure of the ventilator was normalized. We speculated that the tracheal granuloma had occurred due to a tracheal mucosal injury related to endotracheal suctioning. We should pay attention to complaints of dyspnea in ALS patients with tracheostomy and make a careful consideration to airway care including suction management.

  3. Fluoroscopic guidance for placing a double lumen endotracheal tube in adults.

    Science.gov (United States)

    Calenda, Emile; Baste, Jean Marc; Hajjej, Ridha; Rezig, Najiba; Moriceau, Jerome; Diallo, Yaya; Sghaeir, Slim; Danielou, Eric; Peillon, Christophe

    2014-09-01

    The aim of this study was to assess the right placement of the double lumen endotracheal tube with fluoroscopic guidance, which is used in first intention prior to the fiberscope in our institution. This was a prospective observational study. The study was conducted in vascular and thoracic operating rooms. We enrolled 205 patients scheduled for thoracic surgery, with ASA physical statuses of I (n = 37), II (n = 84), III (n = 80), and IV (n = 4). Thoracic procedures were biopsy (n = 20), wedge (n = 34), culminectomy (n = 6), lobectomy (n = 82), pneumonectomy (n = 4), sympathectomy (n = 9), symphysis (n = 47), and thymectomy (n = 3). The intubation with a double lumen tube was performed with the help of a laryngoscope. Tracheal and bronchial balloons were inflated and auscultation was performed after right and left exclusions. One shot was performed to locate the position of the bronchial tube and the hook. Fluoroscopic guidance was used to relocate the tube in case of a wrong position. When the fluoroscopic guidance failed to position the tube, a fiberscope was used. Perioperative collapse of the lung was assessed by the surgeon during the surgery. Correct fluoroscopic image was obtained after the first attempt in 58.5% of patients therefore a misplaced position was encountered in 41.5%. The fluoroscopic guidance allowed an exact repositioning in 99.5% of cases, and the mean duration of the procedure was 8 minutes. A fiberscope was required to move the hook for one patient. We did not notice a moving of the double lumen endotracheal tube during the surgery. The surgeon satisfaction was 100%. The fluoroscopy evidenced the right position of the double lumen tube and allowed a right repositioning in 99.5% of patients with a very simple implementation. Copyright © 2014. Published by Elsevier B.V.

  4. Tracheal transplantation for carinal reconstruction in dogs.

    Science.gov (United States)

    Kawahara, K; Inutsuka, K; Hiratsuka, M; Makihata, S; Okabayashi, K; Shiraishi, T; Shirakusa, T

    1998-09-01

    Experimental carinal allotransplantation has been performed with tracheocarinal Y-shaped allografts in dogs. In this study we tried canine carinal reconstruction with cylindrical allografts. Carinal reconstruction was performed with allotransplantation of cylindrical trachea in dogs, and graft healing was evaluated by bronchoscopic observation, mucosal blood flow measurement, and histologic examination. A section of the recipient carina containing five tracheal rings and two main stem bronchi was removed, and a donor trachea seven rings long was inserted between the recipient trachea and the left main stem bronchus; then side-to-end anastomosis was performed between the graft midportion and recipient right main stem bronchus (new carina). The grafts were wrapped with pedicled omentum. Fresh grafts were transplanted into one group of dogs (n=8 ), and grafts cryopreserved for 1 week were transplanted into another group (n=7). No anastomotic leakage occurred in any dog. Excellent healing of grafts and graft anastomoses was observed by fiberoptic bronchoscopy in six dogs (75%) in the fresh graft group and in four dogs (57%) in the cryopreserved graft group. The mucosal blood flow in the new carina decreased remarkably and, although it recovered, mucosal blood flow remained under the preoperative level on day 28 after the operation. Cylindrical tracheal allotransplantation is useful for carinal reconstruction, and the method of side-to-end anastomosis between the donor trachea and recipient bronchus is a feasible and accessible procedure in dogs.

  5. Groningen Dilatation Tracheoscope in Treatment of Moderate Subglottic and Tracheal Stenosis

    NARCIS (Netherlands)

    Halmos, Gyorgy; van der Laan, Bernard F. A. M.; Dikkers, Frederik G.

    Objectives: We describe our experience with the Groningen Dilatation Tracheoscope (Karl Storz GmbH & Co, Tuttlingen, Germany) in treating benign subglottic and tracheal stenosis. Methods: We performed a retrospective survey from a medical record analysis of 26 patients with different origins of

  6. Damping-controlled fluidelastic instability forces in multi-span tubes with loose supports

    International Nuclear Information System (INIS)

    Hassan, Marwan A.; Rogers, Robert J.; Gerber, Andrew G.

    2011-01-01

    This paper presents simulations of a loosely supported multi-span tube subjected to turbulence and fluidelastic instability forces in order to compare several time-domain fluid force models simulating the damping-controlled fluidelastic instability mechanism in tube arrays. These models include the negative damping model based on the Connors equation, fluid force coefficient-based models (Chen; Tanaka and Takahara), and two semi-analytical models (Price and Paidoussis; and Lever and Weaver). Time domain modelling challenges for each of these theories are discussed. The implemented models are validated against available experimental data. The linear simulations (without tube/support clearance) show that the Connors-equation based model exhibits the most conservative prediction of the critical flow velocity when the recommended design values for the Connors equation are used. The models are then utilized to simulate the nonlinear response of a three-span cantilever tube in a lattice bar support subjected to air crossflow. The tube is subjected to a single-phase flow passing over the spans where the flow velocity and the support clearance are varied. Special attention is paid to the tube/support interaction parameters that affect wear, such as impact forces, contact ratio, and normal work rate. As was seen for the linear cases, the reduced flow velocity at the instability threshold differs for the fluid force models considered. The investigated models do, however, exhibit similar response characteristics for the impact force, tip lift response, and work rate, except for the Connors-based model that overestimates the response and the tube/support interaction parameters for the loose support case, especially at large clearances.

  7. Bronchial intubation could be detected by the visual stethoscope techniques in pediatric patients.

    Science.gov (United States)

    Kimura, Tetsuro; Suzuki, Akira; Mimuro, Soichiro; Makino, Hiroshi; Sato, Shigehito

    2012-12-01

    We created a system that allows the visualization of breath sounds (visual stethoscope). We compared the visual stethoscope technique with auscultation for the detection of bronchial intubation in pediatric patients. In the auscultation group, an anesthesiologist advanced the tracheal tube, while another anesthesiologist auscultated bilateral breath sounds to detect the change and/or disappearance of unilateral breath sounds. In the visualization group, the stethoscope was used to detect changes in breath sounds and/or disappearance of unilateral breath sounds. The distance from the edge of the mouth to the carina was measured using a fiberoptic bronchoscope. Forty pediatric patients were enrolled in the study. At the point at which irregular breath sounds were auscultated, the tracheal tube was located at 0.5 ± 0.8 cm on the bronchial side from the carina. When a detectable change of shape of the visualized breath sound was observed, the tracheal tube was located 0.1 ± 1.2 cm on the bronchial side (not significant). At the point at which unilateral breath sounds were auscultated or a unilateral shape of the visualized breath sound was observed, the tracheal tube was 1.5 ± 0.8 or 1.2 ± 1.0 cm on the bronchial side, respectively (not significant). The visual stethoscope allowed to display the left and the right lung sound simultaneously and detected changes of breath sounds and unilateral breath sound as a tracheal tube was advanced. © 2012 Blackwell Publishing Ltd.

  8. [POSTRESUSCITATION CICATRICIAL TRACHEAL STENOSIS. CURRENT STATE OF THE PROBLEM - THE SUCCESSES, THE HOPES AND DISAPPOINTMENTS.

    Science.gov (United States)

    Parshin, V D; Vyzhigina, M A; Rusakov, M A; Parshin, V V; Titov, V A; Starostin, A V

    2016-09-01

    Currently, the trend continues to increase the number ofpatients with cicatricial tracheal stenosis (CTS). Therefore, prevention and treatment ofthis disease remains topical. The main cause ofcicatricial tracheal stenosis is damaging the trachea during mechanical ventilation. The scheme ofprevention of this disease in Russia hasn't brought the desired results. to clarify the modern etiology of cicatricial tracheal stenosis, to identify the trend in incidence rates, to determine whether there is an optimal safe alternative to tracheostomy including the use of minimally invasive techniques, to improve diagnostic and therapeutic algorithm at various stages of assistance, and also to study the results of innovative operations and new ways of maintaining gas exchange. 1128 patients with cicatricial tracheal stenosis was treated from 1963 to 2015 in Petrovsky National Research Centre of Surgery and IMSechenov First Moscow State Medical University. Over time methods of di- agnosis, methods of anesthesia and operations have been varied. In this regard all patients were divided into two groups depending on the period of time from 1963 to 2000 (297 patients) andfrom 2001 to 2015 (831 patients). In recent decades there is a steady increase in the number of treated patients. So, if in the first group during the year operational treatment about the CTS 8,0 patients were underwent, in the second - to 55.4. Cicatricial tracheal stenosis appeared after lung mechanical ventilation at 1025 (for 90.9%) patients. They have undergone both radical one-stage treatment and multi-stage and sequential intraluminal procedures. In general there is a clear trend towards more aggressive surgical tactics. So, if in thefirst group, the tracheal resection with anastomosis was performedin 59 patients only, the second-330. Thefrequency ofpostoperative complications and mortality in the second group ofpatients was 12.9 and 0.7 %, respectively. Only a reasonable combination of all treatment methods

  9. Tracheal cuff pressure monitoring in the ICU: a literature review and survey of current practice in Queensland.

    Science.gov (United States)

    Talekar, C R; Udy, A A; Boots, R J; Lipman, J; Cook, D

    2014-11-01

    The application of tracheal cuff pressure monitoring is likely to vary between institutions. The aim of this study was therefore to review current evidence concerning this intervention in the intensive care unit (ICU) and to appraise regional practice by performing a state-wide survey. Publications for review were identified through searches of PubMed, EMBASE and Cochrane (1977 to 2014). All studies in English relevant to critical care and with complete data were included. Survey questions were developed by small-group consensus. Public and private ICUs across Queensland were contacted, with responses obtained from a representative member of the medical or nursing staff. Existing literature suggests significant variability in tracheal cuff pressure monitoring in the ICU, particularly in the applied technique, frequency of assessment and optimal intra-cuff pressures. Twenty-nine respondents completed the survey, representing 80.5% (29/36) of ICUs in Queensland. Twenty-eight out of twenty-nine respondents reported routinely monitoring tracheal cuff function, primarily employing cuff pressure measurement (26/28). Target cuff pressures varied, with 3/26 respondents aiming for 10 to 20 cmH2O, 10/26 for 21 to 25 cmH2O, and 13/26 for 26 to 30 cmH2O. Fifteen out of twenty-nine reported they had no current guideline or protocol for tracheal cuff management and only 16/29 indicated there was a dedicated area in the clinical record for reporting cuff intervention. Our results indicate that many ICUs across Queensland routinely measure tracheal cuff function, with most utilising pressure monitoring devices. Consistent with existing literature, the optimum cuff pressure remains uncertain. Most, however, considered that this should be a routine part of ICU care.

  10. Integrated Computer Controlled Glow Discharge Tube

    Science.gov (United States)

    Kaiser, Erik; Post-Zwicker, Andrew

    2002-11-01

    An "Interactive Plasma Display" was created for the Princeton Plasma Physics Laboratory to demonstrate the characteristics of plasma to various science education outreach programs. From high school students and teachers, to undergraduate students and visitors to the lab, the plasma device will be a key component in advancing the public's basic knowledge of plasma physics. The device is fully computer controlled using LabVIEW, a touchscreen Graphical User Interface [GUI], and a GPIB interface. Utilizing a feedback loop, the display is fully autonomous in controlling pressure, as well as in monitoring the safety aspects of the apparatus. With a digital convectron gauge continuously monitoring pressure, the computer interface analyzes the input signals, while making changes to a digital flow controller. This function works independently of the GUI, allowing the user to simply input and receive a desired pressure; quickly, easily, and intuitively. The discharge tube is a 36" x 4"id glass cylinder with 3" side port. A 3000 volt, 10mA power supply, is used to breakdown the plasma. A 300 turn solenoid was created to demonstrate the magnetic pinching of a plasma. All primary functions of the device are controlled through the GUI digital controllers. This configuration allows for operators to safely control the pressure (100mTorr-1Torr), magnetic field (0-90Gauss, 7amps, 10volts), and finally, the voltage applied across the electrodes (0-3000v, 10mA).

  11. Interventional bronchoscopy for treatment of tracheal obstruction secondary to benign or malignant thyroid disease.

    Science.gov (United States)

    Noppen, Marc; Poppe, Kris; D'Haese, Jan; Meysman, Marc; Velkeniers, Brigitte; Vincken, Walter

    2004-02-01

    Surgery is the treatment of choice for symptomatic tracheal obstruction due to benign or malignant thyroid disease. In case of inoperability, or when surgery is refused, few therapeutic alternatives are available. Interventional bronchoscopic procedures have only been reported anecdotally. The objective of this study is to evaluate the results of interventional bronchoscopic procedures in the treatment of severe tracheal obstruction due to thyroid disease. Retrospective cohort analysis. University hospital, tertiary referral center. Thirty consecutive patients referred for bronchoscopic treatment of benign (n = 17) or malignant (n = 13) thyroid-related upper airway obstruction due to tracheomalacia, extrinsic compression, and/or tracheal ingrowth. Indications for bronchoscopic treatment were medical or surgical inoperability, prevention or treatment of tracheomalacia, and refusal of surgery. There were no procedure-related complications. Rigid bronchoscopy with dilatation, stenting and/or Nd-YAG laser treatment, and clinical follow-up. Subjective improvement, pulmonary function tests, early and late complications, and survival. In the benign group, immediate (100% relief of dyspnea) and long-term (88% relief of dyspnea) results were excellent after airway stenting (21 stents used in 17 patients). There was one unrelated death 1 week after stenting in a 98-year-old patient. There were 6% and 30% short-term and long-term complications, respectively, that could be managed endoscopically. In the malignant group, Nd-YAG laser treatment (n = 3) and stenting (n = 13) yielded immediate and long-term success in 92% of patients. There were 15% short-term and 8% long-term complications. Median survival time was 540 days. Interventional bronchoscopic procedures including Nd-YAG laser treatment and stenting are valuable alternatives to surgery in inoperable thyroid-induced tracheal obstruction, or when surgery is refused.

  12. Manipulation of gene expression by infrared laser heat shock and its application to the study of tracheal development in Drosophila.

    Science.gov (United States)

    Miao, Guangxia; Hayashi, Shigeo

    2015-03-01

    Induction of gene expression in a specific cell and a defined time window is desirable to investigate gene function at the cellular level during morphogenesis. To achieve this, we attempted to introduce the infrared laser-evoked gene operator system (IR-LEGO, Kamei et al., 2009) in the Drosophila embryo. In this technique, infrared laser light illumination induces genes to be expressed under the control of heat shock promoters at the single cell level. We applied IR-LEGO to a transgenic fly stock, HS-eGFP, in which the enhanced green fluorescent protein (eGFP) gene is placed under the control of heat shock protein 70 promoter, and showed that eGFP expression can be induced in single cells within 1-2 hr after IR illumination. Furthermore, induction of HS-Branchless transgene encoding the Drosophila fibroblast growth factor (FGF) effectively altered the migration and branching patterns of the tracheal system. Our results indicated that IR-LEGO is a promising choice for the timely control of gene expression in a small group of cells in the Drosophila embryo. By using IR-LEGO, we further demonstrated that the tracheal terminal branching program is sensitive to localized expression of exogenous FGF. © 2014 Wiley Periodicals, Inc.

  13. Tracheal intubation by inexperienced medical residents using the Airtraq and Macintosh laryngoscopes--a manikin study.

    LENUS (Irish Health Repository)

    Maharaj, Chrisen H

    2006-11-01

    The Airtraq laryngoscope is a novel intubation device that may possess advantages over conventional direct laryngoscopes for use by personnel that are infrequently required to perform tracheal intubation. We conducted a prospective study in 20 medical residents with little prior airway management experience. After brief didactic instruction, each participant took turns performing laryngoscopy and intubation using the Macintosh (Welch Allyn, Welch Allyn, NY) and Airtraq (Prodol Ltd. Vizcaya, Spain) devices, in 3 laryngoscopy scenarios in a Laerdal Intubation Trainer (Laerdal, Stavanger, Norway) and 1 scenario in a Laerdal SimMan manikin (Laerdal, Kent, UK). They then performed tracheal intubation of the normal airway a second time to characterize the learning curve. In all scenarios tested, the Airtraq decreased the duration of intubation attempts, reduced the number of optimization maneuvers required, and reduced the potential for dental trauma. The residents found the Airtraq easier to use in all scenarios compared with the Macintosh laryngoscope. The Airtraq may constitute a superior device for use by personnel infrequently required to perform tracheal intubation.

  14. [Pain assessment of tracheal suctioning on brain injury patients by pain behavioral indicator scale (ESCID)].

    Science.gov (United States)

    López-López, C; Murillo-Pérez, M A; Morales-Sánchez, C; Torrente-Vela, S; Orejana-Martín, M; García-Iglesias, M; Cuenca-Solanas, M; Alted-López, E

    2014-01-01

    To assess pain response on patients with moderate to severe head injury before a common nursing procedure: tracheal suctioning. An observational longitudinal pilot study with consecutive sampling performed from September to December of 2012. Pain was assessed by a pain behavioral indicator scale 5 minutes before, meanwhile and 15 minutes after tracheal suctioning the days 1, 3 and 6 of their intensive care unit (ICU) stay, as well as a non-painful procedure: rubbing with gauze the forearm of the patient. Pseudo-analgesia and hemodynamic variables were also recorded. Descriptive analysis of the variables, inferential statistics with t-student and Anova with SPSS 17.0; statistical tests were considered significant if the critical level observed was less than 5% (P.05) were shown. Data for the painless procedure were significantly different on day 6 (P<.05) CONCLUSION: During tracheal suctioning in patients with head injury in the first 6 days in the ICU, objective mild-moderate pain according to ESCID scale has been detected. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  15. Experimental and numerical analysis of heat transfer phenomena in a sensor tube of a mass flow controller

    International Nuclear Information System (INIS)

    Jang, Seok Pil; Kim, Sung Jin; Choi, Do Hyung

    2000-01-01

    As a mass flow controller is widely used in many manufacturing processes for controlling a mass flow rate of gas with accuracy of 1%, several investigators have tried to describe the heat transfer phenomena in a sensor tube of an MFC. They suggested a few analytic solutions and numerical models based on simple assumptions, which are physically unrealistic. In the present work, the heat transfer phenomena in the sensor tube of the MFC are studied by using both experimental and numerical methods. The numerical model is introduced to estimate the temperature profile in the sensor tube as well as in the gas stream. In the numerical model, the conjugate heat transfer problem comprising the tube wall and the gas stream is analyzed to fully understand the heat transfer interaction between the sensor tube and the fluid stream using a single domain approach. This numerical model is further verified by experimental investigation. In order to describe the transport of heat energy in both the flow region and the sensor tube, the Nusselt number at the interface between the tube wall and the gas stream as well as heatlines is presented from the numerical solution

  16. Dose response of tracheal epithelial cells to ionizing radiation in air-liquid interface cultures

    International Nuclear Information System (INIS)

    Fukutsu, K.; Yamada, Y.; Shimo, M.

    2002-01-01

    The dose-response relationships of tracheal epithelial cells to ionizing radiation was examined in air-liquid interface cultures, which were developed for the purpose of simulating in vivo conditions. The cultures investigated in this study were expected to be advantageous for the performance of irradiation experiments using short-range α rays. The level of dose response of air-liquid interface cultures to ionizing radiation proved to be the same as that for in vivo conditions. This result indicates that air-liquid interface cultures will prove most useful, to facilitate future studies for the investigation of the biological effects induced in tracheal epithelial cells by ionizing radiation, especially by α-rays. (orig.)

  17. Sonographic Findings of Primary Tracheal Lymphoma: Case Report

    International Nuclear Information System (INIS)

    Kim, Min Sung; Ahn, Kook Jin; Kim, Jee Young; Kim, Hyo Lim; Park, Jeong Mi

    2010-01-01

    Primary lymphoma of the trachea is extremely rare and clinical presentation is nonspecific. CT findings are focal tracheal narrowing caused by a solitary mass or polypoid thickening of the tracheobronchial wall caused by diffuse infiltration of the submucosa. However, US finding of primary lymphoma of the trachea has been not reported. We experienced a case of primary lymphoma of the trachea presenting as a homogenous hypoechoic mass, and discuss ultrasonographic and CT findings of the case

  18. Muscarinic receptors, nitric oxide formation and cyclooxygenase pathway involved in tracheal smooth muscle relaxant effect of hydro-ethanolic extract of Lavandula angustifolia flowers.

    Science.gov (United States)

    Naghdi, Farzaneh; Gholamnezhad, Zahra; Boskabady, Mohammad Hossein; Bakhshesh, Morteza

    2018-06-01

    Lavandula angustifolia (L. angustifolia) Mill. (Common name Lavender) is used in traditional and folk medicines for the treatment of various diseases including respiratory disorders worldwide. The relaxant effect of the plant on the smooth muscle of some tissues was shown previously. The present study has investigated the role of different receptors and pathways in the relaxant effect of L. angustifolia on tracheal smooth muscle. Cumulative concentrations of the hydro-ethanolic extract of L. angustifolia flowers (0.5, 1, 2 and 4 mg/ml) were added on pre-contracted tracheal smooth muscle by methacholine (10 μM) or KCl (60 mM) on non-preincubated or preincubated tissues with atropine, chlorpheniramine, propranolol, diltiazem, glibenclamide, indomethacin, ω-nitro-L-arginine methyl ester (L-NAME) and papaverine. The results compared with of theophylline (0.2, 0.4, 0.6 and 0.8 mM) as positive control and saline (1 ml) as negative control. The extract showed concentration-dependent relaxant effects in non-preincubated tracheal smooth muscle contracted by KCl and methacholine (p effect ofL. angustifolia was not significantly different between non-preincubated and preincubated tissues with chlorpheniramine, propranolol, diltiazem, glibenclamide, and papaverine. However, two higher concentrations of L. angustifolia in preincubated tissues with L-NAME (p effects than non-preincubated tissues. The EC 50 values of L. angustifolia in tissues preincubated with indomethacin was significantly higher than non-preincubated trachea (p effects of three first concentrations of the extract on KCl and methacholine-induced muscle contraction were significantly lower than those of theophylline (p effect ofL. angustifolia that was lower than the effect of theophylline. The possible mechanisms of relaxant effect of this plant on tracheal smooth muscle are muscarinic receptors blockade, inhibition of cyclooxygenase pathways and/or involvement of nitric oxide production

  19. Fetoscopic tracheal occlusion for severe congenital diaphragmatic hernia: retrospective study

    Directory of Open Access Journals (Sweden)

    Angélica de Fátima de Assunção Braga

    Full Text Available Abstract Background and objectives: The temporary fetal tracheal occlusion performed by fetoscopy accelerates lung development and reduces neonatal mortality. The aim of this paper is to present an anesthetic experience in pregnant women, whose fetuses have diaphragmatic hernia, undergoing fetoscopic tracheal occlusion (FETO. Method: Retrospective, descriptive study, approved by the Institutional Ethics Committee. Data were obtained from medical and anesthetic records. Results: FETO was performed in 28 pregnant women. Demographic characteristics: age 29.8 ± 6.5; weight 68.64 ± 12.26; ASA I and II. Obstetric: IG 26.1 ± 1.10 weeks (in FETO; 32.86 ± 1.58 (reversal of occlusion; 34.96 ± 2.78 (delivery. Delivery: cesarean section, vaginal delivery. Fetal data: Weight (g in the occlusion and delivery times, respectively (1045.82 ± 222.2 and 2294 ± 553; RPC in FETO and reversal of occlusion: 0.7 ± 0.15 and 1.32 ± 0.34, respectively. Preoperative maternal anesthesia included ranitidine and metoclopramide, nifedipine (VO and indomethacin (rectal. Preanesthetic medication with midazolam IV. Anesthetic techniques: combination of 0.5% hyperbaric bupivacaine (5-10 mg and sufentanil; continuous epidural predominantly with 0.5% bupivacaine associated with sufentanil, fentanyl, or morphine; general. In 8 cases, there was need to complement via catheter, with 5 submitted to PC and 3 to BC. Thirteen patients required intraoperative sedation; ephedrine was used in 15 patients. Fetal anesthesia: fentanyl 10-20 mg.kg-1 and pancuronium 0.1-0.2 mg.kg-1 (IM. Neonatal survival rate was 60.7%. Conclusion: FETO is a minimally invasive technique for severe congenital diaphragmatic hernia repair. Combined blockade associated with sedation and fetal anesthesia proved safe and effective for tracheal occlusion.

  20. Tracheal ceramic rings for tracheomalacia: a review after 17 years.

    Science.gov (United States)

    Göbel, Gyula; Karaiskaki, Niki; Gerlinger, Imre; Mann, Wolf J

    2007-10-01

    Despite different support techniques, the surgical management of tracheomalacia is still a challenging problem. Satisfactory results after internal stenting are above 80%, whereas, when performing external stenting using biocompatible ceramic rings, results are reported at over 90%. The purpose of this study was to examine the efficiency of surgical treatment in patients with segmentary tracheomalacia using external ceramic ring grafts. In this retrospective study, we collected data from 12 patients who underwent surgery during the last 17 years for symptomatic segmentary tracheomalacia by use of biocompatible aluminum-oxide ceramic rings. All except one patient had undergone previous tracheostomy, six had a history of long-term intubation, two had previous trauma, and two patients had previous cancer treatment including radiotherapy. One of the patients still had an existing tracheostoma, which was closed when a ceramic ring was implanted. Tracheal wall collapse with pseudoglottis formation or flattened anterior-posterior tracheal diameter was documented with fiberoscopy at rest, and both pre- and postoperative airway resistance measurements were performed in all 12 patients using a spirometer. After malacic segments were found to be expandable using rigid tracheoscopy while the patient was under general anesthesia, preparation of the trachea was performed using a midline vertical incision in the neck. Subsequently, the malacic trachea was expanded by placing and suturing proper-sized ceramic ring(s) around it. In all patients, surgical expansion of the malacic segment using ceramic rings was successfully carried out without major complications while inspiratory stridor was resolved. Airway resistance decreased significantly from an average of 0.62 to 0.385 kPascal. Although the results of applying internal tracheal stents are encouraging, complications such as stent migration, granulation tissue and fistula formation, and mucociliary transport arrest are possible

  1. [Investigation of radiation dose for lower tube voltage CT using automatic exposure control].

    Science.gov (United States)

    Takata, Mitsuo; Matsubara, Kousuke; Koshida, Kichirou; Tarohda, Tohru

    2015-04-01

    The purpose of our study was to investigate radiation dose for lower tube voltage CT using automatic exposure control (AEC). An acrylic body phantom was used, and volume CT dose indices (CTDIvol) for tube voltages of 80, 100, 120, and 135 kV were investigated with combination of AEC. Average absorbed dose in the abdomen for 100 and 120 kV were also measured using thermoluminescence dosimeters. In addition, we examined noise characteristics under the same absorbed doses. As a result, the exposure dose was not decreased even when the tube voltage was lowered, and the organ absorbed dose value became approximately 30% high. And the noise was increased under the radiographic condition to be an equal absorbed dose. Therefore, radiation dose increases when AEC is used for lower tube voltage CT under the same standard deviation (SD) setting with 120 kV, and the optimization of SD setting is crucial.

  2. Endotracheal tube cufi pressures in adult patients undergoing ...

    African Journals Online (AJOL)

    obstructing tracheal mucosal blood flow but high enough to form an effective seal when delivering PPV. Tracheal ... the capillary blood pressure supplying the trachea and is followed by ischaemia with inflammation. ... The aim of this study was to determine the ETT cuff pressures of patients receiving general anaesthesia at ...

  3. Tracheal reaction to three different intraluminal stents in an animal model of tracheomalacia.

    Science.gov (United States)

    Weinberg, Mark; Sandbank, Judith; Flumenblit, Yoseph; Klin, Baruch; Vinograd, Itzhak

    2005-06-01

    Three different internal airway stents were studied in an animal model of tracheomalacia: the Palmaz stent (Johnson & Johnson, Warren, New Jersey) and the NIR stent (Medinol Ltd., Tel Aviv, Israel)--both made of stainless steel in the form of tubular mesh--and the Nitinol stent, made of nickel-titanium formed into a spiral shape. All three stents could be adequately stabilized in the malacic tracheal segment. The Nitinol stent (Medinol Ltd., Tel Aviv, Israel) proved to be less reactive to the tracheal mucosa, demonstrated higher biocompatibility with significantly less granulation tissue formation, and showed superior radial resistance. Extraction of the Nitinol stent also proved to be much smoother. This stent may be the stent of choice in the treatment of tracheo- and bronchomalacia.

  4. Composite cervical skin and cartilage flap provides a novel large airway substitute after long-segment tracheal resection.

    Science.gov (United States)

    Fabre, Dominique; Singhal, Sunil; De Montpreville, Vincent; Decante, Benoit; Mussot, Sacha; Chataigner, Olivier; Mercier, Olaf; Kolb, Frederic; Dartevelle, Philippe G; Fadel, Elie

    2009-07-01

    Airway replacement after long-segment tracheal resection for benign and malignant disease remains a challenging problem because of the lack of a substitute conduit. Ideally, an airway substitute should be well vascularized, rigid, and autologous to avoid infections, airway stenosis, and the need for immunosuppression. We report the development of an autologous tracheal substitute for long-segment tracheal resection that satisfies these criteria and demonstrates excellent short-term functional results in a large-animal study. Twelve adult pigs underwent long-segment (6 cm, 60% of total length) tracheal resection. Autologous costal cartilage strips measuring 6 cm x 2 mm were harvested from the chest wall and inserted at regular 0.5-cm intervals between dermal layers of a cervical skin flap. The neotrachea was then scaffolded by rotating the composite cartilage skin flap around a silicone stent measuring 6 cm in length and 1.4 cm in diameter. The neotrachea replaced the long segment of tracheal resection, and the donor flap site was closed with a double-Z plasty. Animals were killed at 1 week (group I, n = 4), 2 weeks (group II, n = 4), and 5 weeks (group III, n = 4). In group III the stent was removed 1 week before death. Viability of the neotrachea was monitored by means of daily flexible bronchoscopy and histologic examination at autopsy. Long-term morbidity and mortality were determined by monitoring weight gain, respiratory distress, and survival. There was no mortality during the study period. Weight gain was appropriate in all animals. Daily bronchoscopy and postmortem histologic evaluation confirmed excellent viability of the neotrachea. There was no evidence of suture-line dehiscence. Five animals had distal granulomas that were removed by using rigid bronchoscopy. In group III 1 animal had tracheomalacia, which was successfully managed by means of insertion of a silicon stent. Airway reconstruction with autologous cervical skin flaps scaffolded with costal

  5. Application of Electrocautery Needle Knife Combined with Balloon Dilatation versus Balloon Dilatation in the Treatment of Tracheal Fibrotic Scar Stenosis.

    Science.gov (United States)

    Bo, Liyan; Li, Congcong; Chen, Min; Mu, Deguang; Jin, Faguang

    Electrocautery needle knives can largely reduce scar and granulation tissue hyperplasia and play an important role in treating patients with benign stricture. The aim of this retrospective study was to evaluate the efficacy and safety of electrocautery needle knife combined with balloon dilatation versus balloon dilatation alone in the treatment of tracheal stenosis caused by tracheal intubation or tracheotomy. We retrospectively analysed the clinical data of 43 patients with tracheal stenosis caused by tracheotomy or tracheal intubation in our department from January 2013 to January 2016. Among these 43 patients, 23 had simple web-like stenosis and 20 had complex steno sis. All patients were treated under general anaesthesia, and the treatment methods were (1) balloon dilatation alone, (2) needle knife excision of fibrotic tissue combined with balloon dilatation, and (3) needle knife radial incision of fibrotic tissue combined with balloon dilatation. After treatment the symptoms, such as shortness of breath, were markedly improved immediately in all cases. The stenosis degree of patients who were treated with the elec-trocautery needle knife combined with balloon dilatation had better improvement compared with that of those treated with balloon dilatation treatment alone after 3 months (0.45 ± 0.04 vs. 0.67 ± 0.05, p knife combined with balloon dilatation is an effective and safe treatment for tracheal fibrotic stenosis compared with balloon dilatation alone. © 2017 S. Karger AG, Basel.

  6. Intravenous rocuronium 0.3 mg/kg improves the conditions for tracheal intubation in cats: a randomized, placebo-controlled trial.

    Science.gov (United States)

    Sakai, Daniel M; Zornow, Kailee Anne; Campoy, Luis; Cable, Christina; Appel, Leslie D; Putnam, Holly J; Martin-Flores, Manuel

    2018-01-01

    Objectives We evaluated the use of rocuronium 0.3 mg/kg intravenously (IV) to facilitate tracheal intubation in cats anesthetized for elective ovariohysterectomy. Methods Thirty female cats were randomly allocated to receive rocuronium 0.3 mg/kg IV or an equal volume of normal saline, following induction of anesthesia with ketamine and midazolam. Thirty seconds after induction, a single investigator, unaware of treatment allocation, attempted tracheal intubation. The number of attempts and the time to complete intubation were measured. Intubating conditions were assessed as acceptable or unacceptable based on a composite score consisting of five different components. Duration of apnea after induction was measured and cases of hemoglobin desaturation (SpO 2 rocuronium 12 s [range 8-75 s]; saline 60 s [range 9-120 s]) and with fewer attempts (rocuronium 1 [range 1-2]; saline 2 [range 1-3], both P = 0.006) in cats receiving rocuronium. Unacceptable intubating conditions on the first attempt occurred in 3/15 cats with rocuronium and in 10/15 with saline ( P = 0.01). Apnea lasted 4 ± 1.6 mins with rocuronium and 2.3 ± 0.5 mins with saline ( P = 0.0007). No cases of desaturation were observed. Conclusions and relevance Rocuronium 0.3 mg/kg IV improves intubating conditions compared with saline and reduces the time and number of attempts to intubate with only a short period of apnea in cats.

  7. The effect of lidocaine on neutrophil respiratory burst during induction of general anaesthesia and tracheal intubation.

    LENUS (Irish Health Repository)

    Swanton, B J

    2012-02-03

    BACKGROUND AND OBJECTIVE: Respiratory burst is an essential component of the neutrophil\\'s biocidal function. In vitro, sodium thiopental, isoflurane and lidocaine each inhibit neutrophil respiratory burst. The objectives of this study were (a) to determine the effect of a standard clinical induction\\/tracheal intubation sequence on neutrophil respiratory burst and (b) to determine the effect of intravenous lidocaine administration during induction of anaesthesia on neutrophil respiratory burst. METHODS: Twenty ASA I and II patients, aged 18-60 years, undergoing elective surgery were studied. After induction of anaesthesia [fentanyl (2 microg kg-1), thiopental (4-6 mg kg-1), isoflurane (end-tidal concentration 0.5-1.5%) in nitrous oxide (66%) and oxygen], patients randomly received either lidocaine 1.5 mg kg-1 (group L) or 0.9% saline (group S) prior to tracheal intubation. Neutrophil respiratory burst was measured immediately prior to induction of anaesthesia, immediately before and 1 and 5 min after lidocaine\\/saline. RESULTS: Neutrophil respiratory burst decreased significantly after induction of anaesthesia in both groups [87.4 +\\/- 8.2% (group L) and 88.5 +\\/- 13.4% (group S) of preinduction level (P < 0.01 both groups)]. After intravenous lidocaine (but not saline) administration, neutrophil respiratory burst returned towards preinduction levels, both before (97.1 +\\/- 23.6%) and after (94.4 +\\/- 16.6%) tracheal intubation. CONCLUSION: Induction of anaesthesia and tracheal intubation using thiopentone and isoflurane, inhibit neutrophil respiratory burst. This effect may be diminished by the administration of lidocaine.

  8. Numerical calculation for flow field of servo-tube guided hydraulic control rod driving system

    International Nuclear Information System (INIS)

    He Keyu; Han Weishi

    2010-01-01

    A new-style hydraulic control rod driving mechanism was put forward by using servo-tube control elements for the design of control rod driving mechanism. The results of numerical simulation by CFD program Fluent for flow field of hydraulic driving cylinder indicate that the bigger the outer diameter of servo-tube, the smaller the resistance coefficient of variable throttle orifice. The zero position gap of variable throttle orifice could be determined on 0.2 mm in the design. The pressure difference between the upper and nether surfaces of piston was mainly created by the throttle function of fixed throttle orifice. It can be effectively controlled by changing the gap of variable throttle orifice. And the lift force of driving cylinder is able to meet the requirement on the design load. (authors)

  9. Flow mixing inside a control-rod guide tube – Experimental tests and CFD simulations

    International Nuclear Information System (INIS)

    Angele, Kristian; Odemark, Ylva; Cehlin, Mathias; Hemström, Bengt; Högström, Carl-Maikel; Henriksson, Mats; Tinoco, Hernan; Lindqvist, Hans

    2011-01-01

    This paper covers a combined experimental and computational effort carried out at Vattenfall Research and Development AB in order to study the thermal mixing in the annular region between a top tube and a control-rod stem. The low frequency thermal fluctuations in this region can result in problems with thermal fatigue and have caused cracks in the control-rod stems of several nuclear reactors (). The flow in the vertical annular region formed by the top tube and the control-rod stem is characterized by the mixing of hot bypass flow with cold crud-removal flow. The crud-removal flow is flowing upwards along the control-rod stem, and the warmer bypass flow is entering through eight horizontal holes positioned in the lower part of the guide tube and four holes in the upper part of the top tube, forming jets. Two full-scale models of a control rod, including the control-rod stem and the guide tube, were constructed. The first model, designed to work at atmospheric conditions, was made of Plexiglass, in order to be able to visualize the mixing process, whereas the second one was made of steel to allow for a higher temperature difference between the two flows, and the heating of the top tube. CFD simulations of the case at atmospheric conditions were also carried out. Both the experiments and the simulations showed that the mixing region between the cold crud-removal flow and the warm bypass flow is dominated by large flow structures coming from above. The process is characterized by low frequency, high amplitude temperature fluctuations. The process is basically hydrodynamic, caused by the downward transport of flow structures originated at the upper bypass inlets. The damping thermal effects through buoyancy is of secondary importance, as also the scaling analysis shows, however a slight damping of the temperature fluctuations can be seen due to natural convection due to a pre-heating of the cold crud-removal flow. The comparison between numerical and experimental

  10. [Anesthetic Management of Right Lower Lobectomy in a Patient with Marfan Syndrome].

    Science.gov (United States)

    Deguchi, Shiho; Komasawa, Nobuyasu; Matsunami, Sayuri; Kusaka, Yusuke; Ohchi, Fumihiro; Minami, Toshiaki

    2015-05-01

    We report a case of partial lobectomy in a patient with Marfan syndrome. A 56-year-old woman with Marfan syndrome was scheduled for partial lobectomy for suspected lung cancer under general anesthesia. She underwent a Bentall operation and mitral valve replacement 10 months before and strict blood pressure management was required. After induction of general anesthesia with propofol and fentanyl, topical intratracheal lidocaine anesthesia was performed using the Pentax-AWS Airwayscope (AWS) for visualization, allowing for the Soft-tipped Tube Exchanger (TE-Soft) to be inserted into the trachea. Next, a double-lumen tracheal tube was uneventfully intubated via the TE-Soft with minimal change in vital signs. During the operation, pressure-controlled ventilation was performed to minimize the risk of pneumothorax. After the operation, under continuous administration of landiorol and dexmedetomidine, the double-lumen tracheal tube was extubated uneventfully. Strict airway and circulation management is needed for lung or vessel preservation in patients whose conditions are complicated by Marfan syndrome.

  11. Expander for Thin-Wall Tubing

    Science.gov (United States)

    Pessin, R.

    1983-01-01

    Tool locally expands small-diameter tubes. Tube expander locally expands and deforms tube: Compressive lateral stress induced in elastomeric sleeve by squeezing axially between two metal tool parts. Adaptable to situations in which tube must have small bulge for mechanical support or flow control.

  12. Influence of periodic heartbeat reversal and abdominal movements on hemocoelic and tracheal pressure in resting blowflies Calliphora vicina.

    Science.gov (United States)

    Wasserthal, Lutz Thilo

    2012-01-15

    In Calliphoridae and Drosophilidae, the dorsal vessel (heart and aorta with associated venous channels) is the only connection between the thorax and the abdomen. Hemolymph oscillates between the compartments by periodic heartbeat reversal, but both the mechanism and its influence on hemocoelic and tracheal pressure have remained unclear. The pumping direction of the heart regularly reverses, with a higher pulse rate during backward compared with forward pumping. A sequence of forward and backward pulse periods lasts approximately 34 s. Pulse rate, direction, velocity and the duration of heartbeat periods were determined by thermistor and electrophysiological measurements. For the first time, heartbeat-induced pressure changes were measured in the hemocoel and in the tracheal system of the thorax and the abdomen. The tracheal pressure changed from sub-atmospheric during backward heartbeat to supra-atmospheric during forward heartbeat in the thorax and inversely in the abdomen. The heartbeat reversals were coordinated with slow abdominal movements with a pumping stroke at the beginning of the forward pulse period. The pressure effect of the pumping stroke was visible only in the abdomen. Periodic hemolymph shift and abdominal movements resulted in pressure changes in the hemocoel and tracheal system alternating in the thorax and abdomen, suggesting an effect on respiratory gas exchange.

  13. Repair of tracheal epithelium by basal cells after chlorine-induced injury

    Directory of Open Access Journals (Sweden)

    Musah Sadiatu

    2012-11-01

    Full Text Available Abstract Background Chlorine is a widely used toxic compound that is considered a chemical threat agent. Chlorine inhalation injures airway epithelial cells, leading to pulmonary abnormalities. Efficient repair of injured epithelium is necessary to restore normal lung structure and function. The objective of the current study was to characterize repair of the tracheal epithelium after acute chlorine injury. Methods C57BL/6 mice were exposed to chlorine and injected with 5-ethynyl-2′-deoxyuridine (EdU to label proliferating cells prior to sacrifice and collection of tracheas on days 2, 4, 7, and 10 after exposure. Airway repair and restoration of a differentiated epithelium were examined by co-localization of EdU labeling with markers for the three major tracheal epithelial cell types [keratin 5 (K5 and keratin 14 (K14 for basal cells, Clara cell secretory protein (CCSP for Clara cells, and acetylated tubulin (AcTub for ciliated cells]. Morphometric analysis was used to measure proliferation and restoration of a pseudostratified epithelium. Results Epithelial repair was fastest and most extensive in proximal trachea compared with middle and distal trachea. In unexposed mice, cell proliferation was minimal, all basal cells expressed K5, and K14-expressing basal cells were absent from most sections. Chlorine exposure resulted in the sloughing of Clara and ciliated cells from the tracheal epithelium. Two to four days after chlorine exposure, cell proliferation occurred in K5- and K14-expressing basal cells, and the number of K14 cells was dramatically increased. In the period of peak cell proliferation, few if any ciliated or Clara cells were detected in repairing trachea. Expression of ciliated and Clara cell markers was detected at later times (days 7–10, but cell proliferation was not detected in areas in which these differentiated markers were re-expressed. Fibrotic lesions were observed at days 7–10 primarily in distal trachea. Conclusion

  14. Conceptual design of a pressure tube light water reactor with variable moderator control

    International Nuclear Information System (INIS)

    Rachamin, R.; Fridman, E.; Galperin, A.

    2012-01-01

    This paper presents the development of innovative pressure tube light water reactor with variable moderator control. The core layout is derived from a CANDU line of reactors in general, and advanced ACR-1000 design in particular. It should be stressed however, that while some of the ACR-1000 mechanical design features are adopted, the core design basics of the reactor proposed here are completely different. First, the inter fuel channels spacing, surrounded by the calandria tank, contains a low pressure gas instead of heavy water moderator. Second, the fuel channel design features an additional/external tube (designated as moderator tube) connected to a separate moderator management system. The moderator management system is design to vary the moderator tube content from 'dry' (gas) to 'flooded' (light water filled). The dynamic variation of the moderator is a unique and very important feature of the proposed design. The moderator variation allows an implementation of the 'breed and burn' mode of operation. The 'breed and burn' mode of operation is implemented by keeping the moderator tube empty ('dry' filled with gas) during the breed part of the fuel depletion and subsequently introducing the moderator by 'flooding' the moderator tube for the 'burn' part. This paper assesses the conceptual feasibility of the proposed concept from a neutronics point of view. (authors)

  15. Hydro-ethanolic Extract of Portulaca oleracea Affects Beta-adrenoceptors of Guinea Pig Tracheal Smooth Muscle

    Science.gov (United States)

    Boskabady, Mohammad Hossein; Hashemzehi, Milad; Khazdair, Mohammad Reza; Askari, Vahid Reza

    2016-01-01

    Thestimulatory effect of the extract of Portulaca oleracea (P. olerace) on β-adrenoceptor of tracheal smooth muscle was examined.To examine β-adrenoceptor stimulatory effect, concentration response curve to isoprenaline was obtained in pre-contracted tracheal smooth muscle in the presence of three concentrations of aqueous-ethanolic extract, propranolol, and saline. Values of EC50 (the effective concentration of isoprenaline, causing 50% of maximum response) and dose ratio-1(CR-1) were measured. This effect was tested innon-incubated tracheal smooth muscle (group 1) and incubated tissues with chlorpheniramine (group 2). Concentration-response curves to isoprenaline in the presence of two higher concentrations of the extract in group 1 and all three concentrations in group 2 showed leftward shifts compared to isoprenaline curves produced in the presence of saline in both groups. EC50 obtained in the presence of propranolol was significantly higher than that of saline in both groups of experiments (p<0.05 for both cases). However, the EC50 obtained in the presence of two higher concentrations of the extract in group 1 and lower concentration in group 2 were non-significantly but those obtained of medium and high extract concentrations in the group 2 were significantly (p<0.05 for both cases)lower than those of saline. The values of (CR-1) obtained in the presence of all concentrations of the extract in groups1 and 2 were significantly lower than that of propranolol (p<0.05 to p<0.001).The results indicated a stimulatory effect of the P. olerace extract on ß 2-adrenoceptors of tracheal smooth muscle. PMID:28243284

  16. Treatment of primary tracheal carcinoma. The role of external and endoluminal radiotherapy

    International Nuclear Information System (INIS)

    Harms, W.; Wannenmacher, M.; Becker, H.; Herth, F.; Gagel, B.

    2000-01-01

    Background and Purpose: In a retrospective study the role of radiation therapy for the treatment of primary tracheal carcinoma was investigated. Patients and Methods: Between 1984 and 1997, 25 patients with primary tracheal carcinoma were treated with external beam radiotherapy (17 squamous-cell carcinoma [SCC], 8 adenoid cystic carcinoma [ACC], median dose SCC 60 Gy, ACC 55 Gy). An additional brachytherapy boost was carried out in 10/25 patients (median dose SCC 18 Gy, ACC 15 Gy). Ten patients underwent operative treatment. Results: The median survival (Kaplan-Meier) for patients with SCC was 33 months (ACC 94.2). The 1-, 2- and 5-year survival rates (Kaplan-Meier) for patients with SCC were 64.7% (ACC 85.7%), 64.7% (ACC 85.7%), and 26% (ACC 85.7%). Patients with ACC and patients with a complete remission after treatment had a significantly better survival probability (log rank test, p [de

  17. A retropharyngeal-mediastinal hematoma with supraglottic and tracheal obstruction: The role of multidisciplinary airway management

    Directory of Open Access Journals (Sweden)

    Birkholz Torsten

    2010-01-01

    Full Text Available A 77-year-old man suffered hypoxemic cardiac arrest by supraglottic and tracheal airway obstruction in the emergency department. A previously unknown cervical fracture had caused a traumatic retropharyngeal-mediastinal hematoma. A lifesaving surgical emergency tracheostomy succeeded. Supraglottic and tracheal obstruction by a retropharyngeal-mediastinal hematoma with successful resuscitation via emergency tracheostomy after hypoxemic cardiac arrest has never been reported in a context of trauma. This clinically demanding case outlines the need for multidisciplinary airway management systems with continuous training and well-implemented guidelines. Only multidisciplinary staff preparedness and readily available equipments for the unanticipated difficult airway solved the catastrophic clinical situation.

  18. Pressure tube reactor

    International Nuclear Information System (INIS)

    Susuki, Akira; Murata, Shigeto; Minato, Akihiko.

    1993-01-01

    In a pressure tube reactor, a reactor core is constituted by arranging more than two units of a minimum unit combination of a moderator sealing pipe containing a calandria tube having moderators there between and a calandria tube and moderators. The upper header and a lower header of the calandria tank containing moderators are communicated by way of the moderator sealing tube. Further, a gravitationally dropping mechanism is disposed for injecting neutron absorbing liquid to a calandria gas injection portion. A ratio between a moderator volume and a fuel volume is defined as a function of the inner diameter of the moderator sealing tube, the outer diameter of the calandria tube and the diameter of fuel pellets, and has no influence to intervals of a pressure tube lattice. The interval of the pressure tube lattice is enlarged without increasing the size of the pressure tube, to improve production efficiency of the reactor and set a coolant void coefficient more negative, thereby enabling to improve self controllability and safety. Further, the reactor scram can be conducted by injecting neutron absorbing liquid. (N.H.)

  19. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    Langford, O.M.; Peelman, H.E.

    1978-01-01

    Means and method are described for energizing and regulating a neutron generator tube having a target, an ion source and a replenisher. It providing a negative high voltage to the target and monitoring the target current. A constant current from a constant current source is divided into a shunt current and a replenisher current in accordence with the target current. The replenisher current is applied to the replenisher in a neutron generator tube so as to control the neutron output in accordance with the target current

  20. Quality control results of the drift tubes for the ATLAS MDT-BIS chambers

    International Nuclear Information System (INIS)

    Alexopoulos, T.; Avramidou, R.; Dris, M.; Filippas, T.A.; Gazis, E.N.; Katsoufis, E.; Maltezos, S.; Savva, P.; Tsipolitis, G.; Tzamariudaki, E.

    2006-01-01

    ATLAS (A Toroidal LHC ApparatuS) is a general purpose experiment, which will start its operation at the Large Hadron Collider (LHC) at CERN in 2007. The ATLAS detector is designed to study the products of proton-proton collisions at c.m.s. energies of up to 14 TeV. Three Greek Universities have taken the responsibility to construct 112 BIS-MDT (Barrel Inner Small) chambers using 29 000 drift tubes of 170 cm length and 3 cm diameter that have been quality tested before assembly. This work describes the Quality Assurance and Quality Control (QA Q C) procedures for the drift tubes, followed at the High Energy Physics Laboratory of the National Technical University of Athens, while emphasis is given on the obtained results for the above mentioned number of tubes

  1. A microfluidic tubing method and its application for controlled synthesis of polymeric nanoparticles.

    Science.gov (United States)

    Wang, Jidong; Chen, Wenwen; Sun, Jiashu; Liu, Chao; Yin, Qifang; Zhang, Lu; Xianyu, Yunlei; Shi, Xinghua; Hu, Guoqing; Jiang, Xingyu

    2014-05-21

    This report describes a straightforward but robust tubing method for connecting polydimethylsiloxane (PDMS) microfluidic devices to external equipment. The interconnection is irreversible and can sustain a pressure of up to 4.5 MPa that is characterized experimentally and theoretically. To demonstrate applications of this high-pressure tubing technique, we fabricate a semicircular microfluidic channel to implement a high-throughput, size-controlled synthesis of poly(lactic-co-glycolic acid) (PLGA) nanoparticles ranging from 55 to 135 nm in diameter. This microfluidic device allows for a total flow rate of 410 mL h(-1), resulting in enhanced convective mixing which can be utilized to precipitate small size nanoparticles with a good dispersion. We expect that this tubing technique would be widely used in microfluidic chips for nanoparticle synthesis, cell manipulation, and potentially nanofluidic applications.

  2. Effects of hydration and physical therapy on tracheal transport velocity

    International Nuclear Information System (INIS)

    Chopra, S.K.; Taplin, G.V.; Simmons, D.H.; Coulson, A.; Elam, D.

    1976-01-01

    A new tracer method for quantitative measurements of tracheal transport velocity (TTV) in mm/min in dogs has been described recently. Using the same technique, the effects of dehydration, hydration, postural drainage and physical therapy on TTV were studied. There was a significant (p < 0.05) reduction in TTV following dehydration and these values reverted to normal with hydration in all ten dogs. Tracheal transport velocity increased on the average of 39.7 percent with a mean change of 7.7 mm/min (p < 0.01) following postural drainage in seven dogs. On the other hand, TTV increased on the average of 51 percent with a mean change of 8.2 mm/min (p <0.01) following chest percussion in six dogs. Postural drainage and chest percussion each increased TTV significantly beyond the base-line values. However, hydration only restored TTV to base-line values when applied to dogs in the hydropenic state. These therapeutic measures have been used empirically in the past. The present study gives objective evidence of their beneficial effects in dogs and suggests that such treatments may have a definite scientific basis for clinical application in chronic obstructive airways disease

  3. Marital status is an independent prognostic factor for tracheal cancer patients: an analysis of the SEER database.

    Science.gov (United States)

    Li, Mu; Dai, Chen-Yang; Wang, Yu-Ning; Chen, Tao; Wang, Long; Yang, Ping; Xie, Dong; Mao, Rui; Chen, Chang

    2016-11-22

    Although marital status is an independent prognostic factor in many cancers, its prognostic impact on tracheal cancer has not yet been determined. The goal of this study was to examine the relationship between marital status and survival in patients with tracheal cancer. Compared with unmarried patients (42.67%), married patients (57.33%) had better 5-year OS (25.64% vs. 35.89%, p = 0.009) and 5-year TCSS (44.58% vs. 58.75%, p = 0.004). Results of multivariate analysis indicated that marital status is an independent prognostic factor, with married patients showing better OS (hazard ratio [HR] = 0.78, 95% confidence interval [CI] 0.64-0.95, p = 0.015) and TCSS (HR = 0.70, 95% CI 0.54-0.91, p = 0.008). In addition, subgroup analysis suggested that marital status plays a more important role in the TCSS of patients with non-low-grade malignant tumors (HR = 0.71, 95% CI 0.53-0.93, p = 0.015). We extracted 600 cases from the Surveillance, Epidemiology, and End Results (SEER) database. Variables were compared by Pearson chi-squared test, t-test, log-rank test, and multivariate Cox regression analysis. Overall survival (OS) and tracheal cancer-specific survival (TCSS) were compared between subgroups with different pathologic features and tumor stages. Marital status is an independent prognostic factor for survival in patients with tracheal cancer. For that reason, additional social support may be needed for unmarried patients, especially those with non-low-grade malignant tumors.

  4. Fabrication of Chitosan Silk-based Tracheal Scaffold Using Freeze-Casting Method

    Science.gov (United States)

    Nematollahi, Zeinab; Tafazzoli-Shadpour, Mohammad; Zamanian, Ali; Seyedsalehi, Amir; Mohammad-Behgam, Shadmehr; Ghorbani, Fariba; Mirahmadi, Fereshte

    2017-01-01

    Background: Since the treatments of long tracheal lesions are associated with some limitations, tissue engineered trachea is considered as an alternative option. This study aimed at preparing a composite scaffold, based on natural and synthetic materials for tracheal tissue engineering. Methods: Nine chitosan silk-based scaffolds were fabricated using three freezing rates (0.5, 1, and 2°C/min) and glutaraldehyde (GA) concentrations (0, 0.4, and 0.8 wt%). Samples were characterized, and scaffolds having mechanical properties compatible with those of human trachea and proper biodegradability were selected for chondrocyte cell seeding and subsequent biological assessments. Results: The pore sizes were highly influenced by the freezing rate and varied from 135.3×372.1 to 37.8×83.4 µm. Swelling and biodegradability behaviors were more affected by GA rather than freezing rate. Tensile strength raised from 120 kPa to 350 kPa by an increment of freezing rate and GA concentration. In addition, marked stiffening was demonstrated by increasing elastic modulus from 1.5 MPa to 12.2 MPa. Samples having 1 and 2°C/min of freezing rate and 0.8 wt% GA concentration made a non-toxic, porous structure with tensile strength and elastic modulus in the range of human trachea, facilitating the chondrocyte proliferation. The results of 21-day cell culture indicated that glycosaminoglycans content was significantly higher for the rate of 2°C/min (12.04 µg/min) rather than the other (9.6 µg/min). Conclusion: A homogenous porous structure was created by freeze drying. This allows the fabrication of a chitosan silk scaffold cross-linked by GA for cartilage tissue regeneration with application in tracheal regeneration. PMID:28131109

  5. Tracheal obstructions in two horses and a donkey

    International Nuclear Information System (INIS)

    Mair, T.S.; Lane, J.G.

    1990-01-01

    The clinical signs associated with intramural tracheal obstructions in two horses and a donkey were respiratory distress and coughing, which were aggravated by exercise and excitement. The obstructions were at the level of the thoracic inlet and consisted either of flattening of the cartilage rings in the dorsoventral plane or of cartilage rings having a scroll-like conformation. They appeared to be developmental in origin and to have been present for a considerable time before the onset of clinical signs. Endoscopy and radiography were helpful in the diagnosis of the condition

  6. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    1977-01-01

    A means and method for energizing and regulating a neutron generator tube is described. It has a target, an ion source and a replenisher. A negative high voltage is applied to the target and the target current monitored. A constant current from a constant current source is divided into a shunt current and a replenisher current in accordance with the target current. The replenisher current is applied to the replenisher in a neutron generator tube so as to control the neutron output in accordance with the target current. (C.F.)

  7. Case Report of Multiple Tracheostomy Revisions due to Persistent, Recurrent Cuff Leak

    Directory of Open Access Journals (Sweden)

    Jian P. Azimi-Bolourian

    2015-01-01

    Full Text Available This case is a patient with amyotrophic lateral sclerosis who was unable to be separated from mechanical ventilator support and required a tracheostomy. The patient underwent an initial open tracheostomy utilizing flexible fiberoptic tracheoscopy (FFT in the operating room (OR. Subsequently, he developed recurrent leaks in the tracheal tube cuff requiring multiple trips back to the operating room. The recurrent cuff leak occurred following each tube placement until the etiology of the leak was discovered during the fourth procedure. In the fourth procedure, the wound was explored more extensively, and it was found that there was a sharp, calcified, aberrant fragment of a tracheal cartilage ring protruding into the tracheal lumen, which was damaging the cuff of each tube. This fragment was not visible by multiple FFTs, nor was it visible in the wound by the surgeons until wider exploration of the wound occurred. The cartilage fragment was ultimately excised and the patient had no further cuff leaks. Aberrant tracheal cartilage should be on the differential diagnosis for cuff leaks subsequent to surgical tracheostomy (ST or percutaneous dilatational tracheostomy (PDT.

  8. Nitinol stents in the treatment of benign proximal tracheal stenosis or tracheomalacia.

    Science.gov (United States)

    Isa, A Y; Macandie, C; Irvine, B W

    2006-01-01

    Nitinol stents have been used in the treatment of benign tracheal stenosis. A retrospective review of five patients treated at Stobhill Hospital over the last six and a half years is presented. Age at presentation ranged from 17 to 76 years. The minimum follow-up period was 23 months and the maximum was 78 months. All our patients were successfully decannulated, with none requiring recannulation. Four patients developed granulation tissue related to the stent at intervals ranging from three weeks to 41 months post stenting. Topical mitomycin C application has been useful after resection of granulations using the carbon dioxide (CO2) laser. Stent migration occurred in one patient three weeks after insertion. Nitinol stents are easy to insert and effective in the treatment of tracheal stenosis, but can have associated morbidity. Their use should be considered carefully, as insertion should be regarded as permanent. Publications reporting experience and outcome with the use of Nitinol stents in the trachea are reviewed.

  9. A comparison of adenine and some derivatives on pig isolated tracheal muscle.

    Science.gov (United States)

    Bach-Dieterle, Y.; Holden, W. E.; Junod, A. F.

    1983-01-01

    We studied the muscle relaxation induced by adenine and several adenine derivatives in strips of tracheal smooth muscle from pigs; in addition their metabolism by the tissue was examined. Adenine relaxed tissue which was contracted by carbachol, histamine, or KCl. Adenine's potency was similar to that of adenosine and ATP (threshold about 4 X 10(-5)M). In tissues with carbachol-induced tone, the adenine effect differed from adenosine and ATP by being slower in onset and in 'washout' time. Furthermore, neither dipyridamole nor theophylline modified the response to adenine. The relationship was examined between pharmacological effects and the metabolism of [3H]-adenosine and [3H]-adenine. Both substrates were taken up by the tissue and converted to nucleotides, but relaxation correlated with nucleotide accumulation only in the case of [3H]-adenine. We conclude that the site and mechanism of adenine-induced relaxation is different from that of adenosine and ATP in porcine tracheal muscle. PMID:6571222

  10. Comparison of prophylactic effects of polyurethane cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes on ventilator-associated pneumonia.

    Directory of Open Access Journals (Sweden)

    Ata Mahmoodpoor

    2013-07-01

    Full Text Available Because microaspiration of contaminated supraglottic secretions past the endotracheal tube cuff is considered to be central in the pathogenesis of pneumonia, improved design of tracheal tubes with new cuff material and shape have reduced the size and number of folds, which together with the addition of suction ports above the cuff to drain pooled subglottic secretions leads to reduced aspiration of oropharyngeal secretions. So we conducted a study to compare the prophylactic effects of polyurethane-cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes (ETT on ventilator-associated pneumonia. This randomized clinical trial was carried out in a 12 bed surgical intensive care unit. 96 patients expected to require mechanical ventilation more than 96 hours were randomly allocated to one of three following groups: Polyvinyl chloride cuff (PCV ETT, Polyurethane (PU cylindrical Sealguard ETT and PU Taperguard ETT. Cuff pressure monitored every three hours 3 days in all patients. Mean cuff pressure didn't have significant difference between three groups during 72 hours. Pneumonia was seen in 11 patients (34% in group PVC, 8 (25% in Sealguard and 7 (21% in Taperguard group. Changes in mean cuff pressure between Sealguard and PVC tubes and also between Taperguard and PVC tubes did not show any significant difference. There was no significant difference in overinflation between three groups. The use of ETT with PU material results in reducing ventilator-associated pneumonia compared to ETT with PVC cuff. In PU tubes Taperguard has less incidence of ventilator-associated pneumonia compared to Sealguard tubes.

  11. Expandable metal stents for tracheal obstruction: permanent or temporary? A cautionary tale.

    OpenAIRE

    Hind, C R; Donnelly, R J

    1992-01-01

    An expandable metal stent inserted via a long term tracheostomy successfully relieved life threatening respiratory obstruction due to benign tracheal stenosis. Later the patient's tracheostomy suction catheter became stuck on the stent and dislodged it. The stent was removed electively, without damaging the trachea, with a rigid biopsy forceps.

  12. Gastro-tracheal fistula - unusual and life threatening complication after esophagectomy for cancer: a case report

    Directory of Open Access Journals (Sweden)

    Droissart Raphaël

    2009-11-01

    Full Text Available Abstract Background A gastro-tracheal fistula following esophagectomy for cancer is a rare but potentially lethal complication. We report the successful surgical closure after failed endoscopic treatment, of a gastro-tracheal fistula following esophago-gastrectomy for cancer after induction chemo-radiotherapy. Case presentation A 58 year-old male patient presented with a distal third uT3N1 carcinoma of the esophagus. After induction chemo-radiotherapy, he underwent an esophago-gastrectomy with radical lymphadenectomy and reconstruction by gastric pull-up. Immediate postoperative outcome was uneventful. On the 15th postoperative day however, our patient was readmitted in the Intensive Care Unit with severe bilateral basal pneumonia. Three days later a gastro-tracheal fistula was diagnosed upon gastroscopy and bronchoscopy. His good general condition allowed for an endoscopic primary approach which consisted in the insertion of a covered stent in the trachea along with clipping and glueing of the gastric fistular orifice. Two attempts proved unsuccessful. Conclusion After several weeks of conservative measures, surgical re-intervention through a right thoracotomy with transection of the fistula and closure by primary interrupted sutures of both fistular orifices along with intercostal muscle flap interposition led to excellent patient outcome. Oral feeding was started and our patient was discharged.

  13. Tidal volume estimation using the blanket fractal dimension of the tracheal sounds acquired by smartphone.

    Science.gov (United States)

    Reljin, Natasa; Reyes, Bersain A; Chon, Ki H

    2015-04-27

    In this paper, we propose the use of blanket fractal dimension (BFD) to estimate the tidal volume from smartphone-acquired tracheal sounds. We collected tracheal sounds with a Samsung Galaxy S4 smartphone, from five (N = 5) healthy volunteers. Each volunteer performed the experiment six times; first to obtain linear and exponential fitting models, and then to fit new data onto the existing models. Thus, the total number of recordings was 30. The estimated volumes were compared to the true values, obtained with a Respitrace system, which was considered as a reference. Since Shannon entropy (SE) is frequently used as a feature in tracheal sound analyses, we estimated the tidal volume from the same sounds by using SE as well. The evaluation of the performed estimation, using BFD and SE methods, was quantified by the normalized root-mean-squared error (NRMSE). The results show that the BFD outperformed the SE (at least twice smaller NRMSE was obtained). The smallest NRMSE error of 15.877% ± 9.246% (mean ± standard deviation) was obtained with the BFD and exponential model. In addition, it was shown that the fitting curves calculated during the first day of experiments could be successfully used for at least the five following days.

  14. Tidal Volume Estimation Using the Blanket Fractal Dimension of the Tracheal Sounds Acquired by Smartphone

    Directory of Open Access Journals (Sweden)

    Natasa Reljin

    2015-04-01

    Full Text Available In this paper, we propose the use of blanket fractal dimension (BFD to estimate the tidal volume from smartphone-acquired tracheal sounds. We collected tracheal sounds with a Samsung Galaxy S4 smartphone, from five (N = 5 healthy volunteers. Each volunteer performed the experiment six times; first to obtain linear and exponential fitting models, and then to fit new data onto the existing models. Thus, the total number of recordings was 30. The estimated volumes were compared to the true values, obtained with a Respitrace system, which was considered as a reference. Since Shannon entropy (SE is frequently used as a feature in tracheal sound analyses, we estimated the tidal volume from the same sounds by using SE as well. The evaluation of the performed estimation, using BFD and SE methods, was quantified by the normalized root-mean-squared error (NRMSE. The results show that the BFD outperformed the SE (at least twice smaller NRMSE was obtained. The smallest NRMSE error of 15.877% ± 9.246% (mean ± standard deviation was obtained with the BFD and exponential model. In addition, it was shown that the fitting curves calculated during the first day of experiments could be successfully used for at least the five following days.

  15. Impact of Cardiopulmonary Bypass on Respiratory Mucociliary Function in an Experimental Porcine Model.

    Directory of Open Access Journals (Sweden)

    Rodrigo Sánchez-Véliz

    Full Text Available The impact of cardiac surgery using cardiopulmonary bypass (CPB on the respiratory mucociliary function is unknown. This study evaluated the effects of CPB and interruption of mechanical ventilation on the respiratory mucociliary system.Twenty-two pigs were randomly assigned to the control (n = 10 or CPB group (n = 12. After the induction of anesthesia, a tracheostomy was performed, and tracheal tissue samples were excised (T0 from both groups. All animals underwent thoracotomy. In the CPB group, an aorto-bicaval CPB was installed and maintained for 90 minutes. During the CPB, mechanical ventilation was interrupted, and the tracheal tube was disconnected. A second tracheal tissue sample was obtained 180 minutes after the tracheostomy (T180. Mucus samples were collected from the trachea using a bronchoscope at T0, T90 and T180. Ciliary beat frequency (CBF and in situ mucociliary transport (MCT were studied in ex vivo tracheal epithelium. Mucus viscosity (MV was assessed using a cone-plate viscometer. Qualitative tracheal histological analysis was performed at T180 tissue samples.CBF decreased in the CPB group (13.1 ± 1.9 Hz vs. 11.1 ± 2.1 Hz, p < 0.05 but not in the control group (13.1 ± 1 Hz vs. 13 ± 2.9 Hz. At T90, viscosity was increased in the CPB group compared to the control (p < 0.05. No significant differences were observed in in situ MCT. Tracheal histology in the CPB group showed areas of ciliated epithelium loss, submucosal edema and infiltration of inflammatory cells.CPB acutely contributed to alterations in tracheal mucocilliary function.

  16. Inverse heat transfer problem in digital temperature control in plate fin and tube heat exchangers

    Science.gov (United States)

    Taler, Dawid; Sury, Adam

    2011-12-01

    The aim of the paper is a steady-state inverse heat transfer problem for plate-fin and tube heat exchangers. The objective of the process control is to adjust the number of fan revolutions per minute so that the water temperature at the heat exchanger outlet is equal to a preset value. Two control techniques were developed. The first is based on the presented mathematical model of the heat exchanger while the second is a digital proportional-integral-derivative (PID) control. The first procedure is very stable. The digital PID controller becomes unstable if the water volumetric flow rate changes significantly. The developed techniques were implemented in digital control system of the water exit temperature in a plate fin and tube heat exchanger. The measured exit temperature of the water was very close to the set value of the temperature if the first method was used. The experiments showed that the PID controller works also well but becomes frequently unstable.

  17. Strong, corrosion-resistant aluminum tubing

    Science.gov (United States)

    Reed, M. W.; Adams, F. F.

    1980-01-01

    When aluminum tubing having good corrosion resistance and postweld strength is needed, type 5083 alloy should be considered. Chemical composition is carefully controlled and can be drawn into thin-wall tubing with excellent mechanical properties. Uses of tubing are in aircraft, boats, docks, and process equipment.

  18. Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers

    International Nuclear Information System (INIS)

    Kalender, W.A.; Wolf, H.; Suess, C.; Gies, M.; Greess, H.; Bautz, W.A.

    1999-01-01

    We investigated approaches to reducing the dose in CT without impairing image quality. Dose can be reduced for non-circular object cross-sections without a significant increase in noise if X-ray tube current is reduced at angular tube positions where the X-ray attenuation by the patients is small. We investigated different schemes of current modulation during tube rotation by simulation and phantom measurements. Both pre-programmed sinusoidal modulation functions and attenuation-based on-line control of the tube current were evaluated. All relevant scan parameters were varied, including constraints such as the maximum modulation amplitude. A circular, an elliptical and two oval water phantoms were used. Results were validated on six cadavers. Dose reduction of 10-45 % was obtained both in simulations and in measurements for the different non-circular phantom geometries and current modulation algorithms without an increase in pixel noise values. On-line attenuation-based control yielded higher reductions than modulation by a sinusoidal curve. The maximal dose reduction predicted by simulations could not be achieved due to limits in the modulation amplitude. In cadaver studies, a reduction of typically 20-40 % was achieved for the body and about 10 % for the head. Variations of our technique are possible; a slight increase in nominal tube current for high-attenuation projections combined with attenuation-based current modulation still yields significant dose reduction, but also a reduction in the structured noise that may obscure diagnostic details. We conclude that a significant reduction in dose can be achieved by tube current modulation without compromising image quality. Attenuation-based on-line control and a modulation amplitude of at least 90 % should be employed. (orig.)

  19. A decade of using intraluminal tracheal/bronchial stents in the management of tracheomalacia and/or bronchomalacia: is it better than aortopexy?

    Science.gov (United States)

    Valerie, Evans P; Durrant, Audrey C; Forte, Vito; Wales, Paul; Chait, Peter; Kim, Peter C W

    2005-06-01

    We compared the efficacy and clinical outcomes of aortopexy versus tracheal stents in the management of tracheomalacia. A retrospective analysis of 25 consecutive patients undergoing aortopexy (n = 11; 8 boys, 3 girls) or tracheal stents (n = 14; 9 boys, 5 girls) between 1993 and 2003 was performed. Both treatment groups, aortopexy versus stents, were comparable in their mean age of diagnosis, timing of intervention, surgical indications ("dying spell" or failed extubation), and previous underlying conditions. The operative time (190 vs 72 minutes) and blood loss (26 vs 0 mL) were significantly greater in aortopexy group (P stents in place for a mean of 15 (range 2-41) months, 3 of 8 patients with stent removal had significant granulation tissue requiring further dilatation. No death was observed in aortopexy group, whereas 1 stent-related death and 1 cardiac arrest requiring median sternotomy occurred during stent removal in 44 and 32 months' follow-up, respectively. Both aortopexy and tracheal stents are effective treatment modalities in the management of tracheomalacia. However, although aortopexy is associated with early perioperative complications, tracheal stents are associated with higher failure rate and more severe stent-related morbidity and mortality.

  20. Inhibitor production by normal rat tracheal epithelial cells influences the frequency of spontaneous and X-ray-induced enhanced growth variants

    International Nuclear Information System (INIS)

    Terzaghi-Howe, M.

    1989-01-01

    A cell culture model was used to assay for the induction of cell populations with enhanced growth capacity in culture in irradiated normal rat tracheal epithelial cells (NTEC). Some growth conditions appear to favor the proliferation of both normal and carcinogen-exposed populations, while others appear to select for populations previously exposed to carcinogen. In the present report we focus on what growth conditions are critical for controlling the emergence of spontaneous and X-ray induced proliferating epithelial foci (PEF) and what factor(s) directly influences the relative frequency of PEF in irradiated and control NTEC cultures. (author)

  1. Determination of the optimal stylet strategy for the C-MAC videolaryngoscope.

    LENUS (Irish Health Repository)

    McElwain, J

    2010-04-01

    The C-MAC videolaryngoscope is a novel intubation device that incorporates a camera system at the end of its blade, thereby facilitating obtaining a view of the glottis without alignment of the oral, pharyngeal and tracheal axes. It retains the traditional Macintosh blade shape and can be used as a direct or indirect laryngoscope. We wished to determine the optimal stylet strategy for use with the C-MAC. Ten anaesthetists were allowed up to three attempts to intubate the trachea in one easy and three progressively more difficult laryngoscopy scenarios in a SimMan manikin with four tracheal tube stylet strategies: no stylet; stylet; directional stylet (Parker Flex-It); and hockey-stick stylet. The use of a stylet conferred no advantage in the easy laryngoscopy scenario. In the difficult scenarios, the directional and hockey-stick stylets performed best. In the most difficult scenario, the median (IQR [range]) duration of the successful intubation attempt was lowest with the hockey-stick stylet; 18 s (15-22 [12-43]) s, highest with the unstyletted tracheal tube; 60 s (60-60 [60, 60]) s and styletted tracheal tube 60 s (29-60 [18-60]) s, and intermediate with the directional stylet 21 s (15-60 [8-60]) s. The use of a stylet alone does not confer benefit in the setting of easy laryngoscopy. However, in more difficult laryngoscopy scenarios, the C-MAC videolaryngoscope performs best when used with a stylet that angulates the distal tracheal tube. The hockey-stick stylet configuration performed best in the scenarios tested.

  2. Results of investigation of spray controlled heat transfer crisis in tubes

    International Nuclear Information System (INIS)

    Sapankevich, A.P.; Kalinina, O.K.; Selivanov, Yu.F.

    1984-01-01

    Coefficient of liquid phase mass transfer is a determining parameter in tubes at crisis controlled with precipitating on heat surface a liquid phase carried in flow. To determine mass transfer coefficients in 4-14 MPa pressure range at 400-2000 kg/m 2 s mass velocities, special experiments were performed in experimental section consisting of two independently heated tubes in-series-connected along the flow. Heat transfer crisis was reached simultaneously in two sections which permitted to eliminate influence of liquid flowing on the wall in the controlsection. A part of heat removed due to forced convection was taken account of during calculation of mass transfer coefficient. Processing results are presented in the criterional form. Mean-square deviation with respect to massive obtained was amounted to 24% during calculation of the mass transfer coefficient and 20% during calculation of critical heat flux

  3. Tracheal intubation in critically ill patients: a comprehensive systematic review of randomized trials.

    Science.gov (United States)

    Cabrini, Luca; Landoni, Giovanni; Baiardo Radaelli, Martina; Saleh, Omar; Votta, Carmine D; Fominskiy, Evgeny; Putzu, Alessandro; Snak de Souza, Cézar Daniel; Antonelli, Massimo; Bellomo, Rinaldo; Pelosi, Paolo; Zangrillo, Alberto

    2018-01-20

    We performed a systematic review of randomized controlled studies evaluating any drug, technique or device aimed at improving the success rate or safety of tracheal intubation in the critically ill. We searched PubMed, BioMed Central, Embase and the Cochrane Central Register of Clinical Trials and references of retrieved articles. Finally, pertinent reviews were also scanned to detect further studies until May 2017. The following inclusion criteria were considered: tracheal intubation in adult critically ill patients; randomized controlled trial; study performed in Intensive Care Unit, Emergency Department or ordinary ward; and work published in the last 20 years. Exclusion criteria were pre-hospital or operating theatre settings and simulation-based studies. Two investigators selected studies for the final analysis. Extracted data included first author, publication year, characteristics of patients and clinical settings, intervention details, comparators and relevant outcomes. The risk of bias was assessed with the Cochrane Collaboration's Risk of Bias tool. We identified 22 trials on use of a pre-procedure check-list (1 study), pre-oxygenation or apneic oxygenation (6 studies), sedatives (3 studies), neuromuscular blocking agents (1 study), patient positioning (1 study), video laryngoscopy (9 studies), and post-intubation lung recruitment (1 study). Pre-oxygenation with non-invasive ventilation (NIV) and/or high-flow nasal cannula (HFNC) showed a possible beneficial role. Post-intubation recruitment improved oxygenation , while ramped position increased the number of intubation attempts and thiopental had negative hemodynamic effects. No effect was found for use of a checklist, apneic oxygenation (on oxygenation and hemodynamics), videolaryngoscopy (on number and length of intubation attempts), sedatives and neuromuscular blockers (on hemodynamics). Finally, videolaryngoscopy was associated with severe adverse effects in multiple trials. The limited available

  4. Successful use of a bulk laxative to control the diarrhea of tube feeding.

    Science.gov (United States)

    Frank, H A; Green, L C

    1979-01-01

    The greatly increased nutritional demands of the severely burned patient frequently require the use of tube feeding for enternal hyperalimentation. At a time when general patient morale is low and motivation needs to be maximally maintained, there is nothing so dispiriting as the distress of a painful perianal region and uncontrollable liquid stools. Attempts to control the diarrhea which frequently accompanies tube feeding by changing the formula or the method of administration or a wide variety of constipating drugs have all met with very limited success. Based on the clinical observation of a noted gastroenterologist (Bockus), we have administered a mucilagenous hydrophilic colloid bulk laxative (Metamucil) to patients on tube feeding formulae. The dosage and frequency are adjusted to individual patient needs, but average 7 g per liter of liquid formula. The results have been dramatic; namely, the virtual elimination of the diarrhea problem in our burn patients on enteral hyperalimentation by gastric tube feeding. Colonic transit time increases. The stools become formed but soft, cohesive but not adhesive. Perianal irritation does not occur. Neither does soilage of wound, dressings, or bed. No rebound constipation or obstructive symptoms have been encountered. We attribute this response to the same water binding mechanism that allows these colloids to prevent chronic constipation. Our patients may be given as much as 5,000 to 6,000 calories of tube feeding per day. Our patients are not distressed by diarrhea. Our nursing staff is relieved of the burden that entails.

  5. Demonstration of a Porous Tube Hydroponic System to Control Plant Moisture and Growth

    Science.gov (United States)

    Dreschel, T. W.; Hall, C. R.; Foster, T. E.

    2003-01-01

    Accurate remote detection of plant health indicators such as moisture, plant pigment concentrations, photosynthetic flux, and other biochemicals in canopies is a major goal in plant research. Influencing factors include complex interactions between wavelength dependent absorbing and scattering features from backgrounds as well as canopy biochemical and biophysical constituents. Accurately controlling these factors in outdoor field studies is difficult. Early testing of a porous tube plant culture system has indicated that plant biomass production, biomass partitioning, and leaf moisture of plants can be controlled by precisely managing the root water potential. Managing nutrient solution chemistry can also control plant pigments, biochemical concentrations, plant biomass production, and photosynthetic rates. A test bed was developed which utilized the porous tube technology with the intent of evaluating remote sensing systems, spectral analyses procedures, gas-exchange, and fluorescence measurements for their ability to detect small differences in plant water status. Spectral analysis was able to detect small differences in the mean leaf water content between the treatments. However these small differences were not detectable in the gas-exchange or fluorescence measurements.

  6. Tracheal volume in the pupa of the Saturniid moth Hyalophora cecropia determined with inert gases.

    Science.gov (United States)

    Bridges, C R; Kestler, P; Scheid, P

    1980-06-01

    Tracheal volume (VTr) was measured in pupae of the Giant silkworm moth Hyalophora cecropia (Saturniidae, Lepidoptera, Insecta) using inert gas wash-out techniques. The animal was placed in a small vessel that was continuously ventilated (rate, V) by a gas mixture containing 20% O2 in N2; the inflowing (F1) and outflowing gas fractions (FE) of the vessel could be continuously measured by a respiratory mass spectrometer. At the onset of a spiracular constriction period, which was evidenced from the FECO2 trace, the mixture was rapidly replaced by pure Ar. At the subsequent burst, the amount of N2 emerging from the animal, MN2, was calculated from V and the difference (FE--F1)N2. VTr was calculated from MN2 and the N2 concentration in the tracheal system before constriction (assumed to equal that in the ventilating gas before replacement by Ar). Measurements were repeated with N2 and Ar replacing each other. VTr average 48 microliter . g-1 (range 39 to 59) for animals of 5.8 g average body weight (range 3.4 to 9.9), when inert gas solubility in body fluids was accounted for. Both size and stage in pupal development appear to affect VTr. These values show reasonable agreement with literature data, mostly obtained by emptying the tracheal gas space by mechanical compression.

  7. Anesthetic considerations for a pediatric patient with Wolf-Hirschhorn syndrome: a case report.

    Science.gov (United States)

    Tsukamoto, Masanori; Yamanaka, Hitoshi; Yokoyama, Takeshi

    2017-09-01

    Wolf-Hirschhorn syndrome is a rare hereditary disease that results from a 4p chromosome deletion. Patients with this syndrome are characterized by craniofacial dysgenesis, seizures, growth delay, intellectual disability, and congenital heart disease. Although several cases have been reported, very little information is available on anesthetic management for patients with Wolf-Hirschhorn syndrome. We encountered a case requiring anesthetic management for a 2-year-old girl with Wolf-Hirschhorn syndrome. The selection of an appropriately sized tracheal tube and maintaining intraoperatively stable hemodynamics might be critical problems for anesthetic management. In patients with short stature, the tracheal tube size may differ from what may be predicted based on age. The appropriate size ( internal diameter ) of tracheal tubes for children has been investigated. Congenital heart disease is frequently associated with Wolf-Hirschhorn syndrome. Depending on the degree and type of heart disease, careful monitoring of hemodynamics is important.

  8. Silicone Stent Placement for Primary Tracheal Amyloidosis Accompanied by Cartilage Destruction

    OpenAIRE

    Ryu, Duck Hyun; Eom, Jung Seop; Jeong, Ho Jung; Kim, Jung Hoon; Lee, Ji Eun; Jun, Ji Eun; Song, Dae Hyun; Han, Joungho; Kim, Hojoong

    2014-01-01

    Primary tracheal amyloidosis (PTA) can lead to airway obstructions, and patients with severe PTA should undergo bronchoscopic interventions in order to maintain airway patency. Focal airway involvements with amyloidosis can only be treated with mechanical dilatation. However, the PTA with diffused airway involvements and concomitant cartilage destructions requires stent placement. Limited information regarding the usefulness of silicone stents in patients with PTA has been released. Therefore...

  9. Alleviating stress response to tracheal extubation in neurosurgical patients: A comparative study of two infusion doses of dexmedetomidine

    Directory of Open Access Journals (Sweden)

    Ankur Luthra

    2017-01-01

    Full Text Available Background: Tracheal extubation is almost always associated with increase in sympathoadrenal activity may result in hypertension, tachycardia, and arrhythmias. Attempts have been made to oppose the pressor response by the use of various drugs. Dexmedetomidine decreases norepinephrine which reduces the blood pressure and the heart rate (HR. We hypothesize that the infusion of dexmedetomidine may produce more stable hemodynamics during extubation as compared to boluses. Materials and Methods: Ninety adult patients aged 18–65 years, the American Society of Anesthesiologists Grade I–II undergoing intracranial surgeries for various neurologic problem at All India Institute of Medical Sciences were enrolled in this randomized controlled trial. Primary Objectives: (1 To observe the hemodynamic changes (HR and mean arterial pressure [MAP] and airway responses during tracheal extubation following two infusion doses of dexmedetomidine. Secondary Objectives: (1 Time to emergence and time to tracheal extubation, (2 Early postoperative complications such as laryngospasm and bronchospasm, and (3 adverse effects of the study drug. Patients were assigned into three groups – (1 Group D0.2 – 0.2 μg/kg/h diluted to 50 ml, (2 Group D0.4 – 0.4 μg/kg/h diluted to 50 ml and Group P (Placebo – 0.9% NS 50 ml. The hemodynamics including the HR and MAP were recorded just before the loading dose of the study drug and then were recorded every 5 min till the infusion was stopped at tracheal extubation and every 1 min till 10 min postextubation. In addition, the airway, respiratory and cardiovascular complications along with postoperative nausea and vomiting, shivering, cough grading, Aldrete score, Ramsay sedation scale, and intraoperative awareness were recorded. Statistical Analysis: Continuous variables such as HR and MAP were analyzed using analysis of variance and categorical variables were analyzed using the Chi-square test. Results: Patient demographics

  10. The infection of chicken tracheal epithelial cells with a H6N1 avian influenza virus.

    Directory of Open Access Journals (Sweden)

    Ching-I Shen

    Full Text Available Sialic acids (SAs linked to galactose (Gal in α2,3- and α2,6-configurations are the receptors for avian and human influenza viruses, respectively. We demonstrate that chicken tracheal ciliated cells express α2,3-linked SA, while goblet cells mainly express α2,6-linked SA. In addition, the plant lectin MAL-II, but not MAA/MAL-I, is bound to the surface of goblet cells, suggesting that SA2,3-linked oligosaccharides with Galβ1-3GalNAc subterminal residues are specifically present on the goblet cells. Moreover, both α2,3- and α2,6-linked SAs are detected on single tracheal basal cells. At a low multiplicity of infection (MOI avian influenza virus H6N1 is exclusively detected in the ciliated cells, suggesting that the ciliated cell is the major target cell of the H6N1 virus. At a MOI of 1, ciliated, goblet and basal cells are all permissive to the AIV infection. This result clearly elucidates the receptor distribution for the avian influenza virus among chicken tracheal epithelial cells and illustrates a primary cell model for evaluating the cell tropisms of respiratory viruses in poultry.

  11. Perioperative management of gastrostomy tube placement in Duchenne muscular dystrophy adolescent and young adult patients: A role for a perioperative surgical home.

    Science.gov (United States)

    Boivin, Ariane; Antonelli, Richard; Sethna, Navil F

    2018-02-01

    In past decades, Duchenne muscular dystrophy patients have been living longer and as the disease advances, patients experience multisystemic deterioration. Older patients often require gastrostomy tube placement for nutritional support. For optimizing the perioperative care, a practice of multidisciplinary team can better anticipate, prevent, and manage possible complications and reduce the overall perioperative morbidity and mortality. The aim of this study was to review our experience with perioperative care of adolescent and young adults with Duchenne muscular dystrophy undergoing gastrostomy by various surgical approaches in order to identify challenges and improve future perioperative care coordination to reduce morbidity. We retrospectively examined cases of gastrostomy tube placement in patients of ages 15 years and older between 2005 and 2016. We reviewed preoperative evaluation, anesthetic and surgical management, and postoperative complications. Twelve patients were identified; 1 had open gastrostomy, 3 laparoscopic gastrostomies, 5 percutaneous endoscopic guided, and 3 radiologically inserted gastrostomy tubes. All patients had preoperative cardiac evaluation with 6 patients demonstrating cardiomyopathy. Nine patients had preoperative pulmonary consultations and the pulmonary function tests reported forced vital capacity of ≤36% of predicted. Eight patients were noninvasive positive pressure ventilation dependent. General anesthesia with tracheal intubation was administered in 8 patients, and intravenous sedation in 4 patients; 1 received sedation supplemented with regional anesthesia and 3 received deep sedation. One patient had a difficult intubation that resulted in trauma and prolonged tracheal intubation. Three patients developed postoperative respiratory complications. Two patients' procedures were postponed due to inadequate preoperative evaluation and 1 because of disagreement between anesthesia and procedural services as to the optimal

  12. Wear plates control rod guide tubes top internal reactor vessel C. N. VANDELLOS II; Desgaste placas tubos guia barras de control interno superior vasija del reactor C.N. Vandellos II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    The guide tubes for control rods forming part of the upper internals of the reactor vessel, its function is to guide the control rod to permit its insertion in the reactor core. These guide tubes are suspended from the upper support plate which are fixed by bolts and extending to the upper core plate which is fastened by clamping bolts (split pin) to prevent lateral displacement of the guide tubes, while allowing axial expansion.

  13. Simulated experimental research on flow field near control rod guide tubes

    International Nuclear Information System (INIS)

    Yu Ping'an; Shen Xiuzhong; Yang Guanyue; He Fangzheng; Gao Weiguo; Zhang Zhiyi; Tian Ji'an

    1997-01-01

    The paper presents the velocity measurement in the 1/4 scale transparent model of PWR pressure vessel upper plenum of 300 MW nuclear power plant by employing dynamic resistance strain foil velocity measurement technology and laser Doppler velocity measurement technology which have no effect on the flow field. In the experiment water is chosen as the fluid. As a result of the measurement the hydraulic load on the control rods is clarified and the experimental basis is provided for the analysis of whether the control rods are moving upward and downward freely and drop rapidly in emergency case by order. Meantime it also provides the experimental basis for the optical design of the control rod guide tubes and bundles

  14. Evaluation of magnesium-yttrium alloy as an extraluminal tracheal stent.

    Science.gov (United States)

    Luffy, Sarah A; Chou, Da-Tren; Waterman, Jenora; Wearden, Peter D; Kumta, Prashant N; Gilbert, Thomas W

    2014-03-01

    Tracheomalacia is a relatively rare problem, but can be challenging to treat, particularly in pediatric patients. Due to the presence of mechanically deficient cartilage, the trachea is unable to resist collapse under physiologic pressures of respiration, which can lead to acute death if left untreated. However, if treated, the outcome for patients with congenital tracheomalacia is quite good because the cartilage tends to spontaneously mature over a period of 12 to 18 months. The present study investigated the potential for the use of degradable magnesium-3% yttrium alloy (W3) to serve as an extraluminal tracheal stent in a canine model. The host response to the scaffold included the formation of a thin, vascularized capsule consisting of collagenous tissue and primarily mononuclear cells. The adjacent cartilage structure was not adversely affected as observed by bronchoscopic, gross, histologic, and mechanical analysis. The W3 stents showed reproducible spatial and temporal fracture patterns, but otherwise tended to corrode quite slowly, with a mix of Ca and P rich corrosion product formed on the surface and observed focal regions of pitting. The study showed that the approach to use degradable magnesium alloys as an extraluminal tracheal stent is promising, although further development of the alloys is required to improve the resistance to stress corrosion cracking and improve the ductility. Copyright © 2013 Wiley Periodicals, Inc.

  15. Gastrostomy Tube (G-Tube)

    Science.gov (United States)

    ... any of these problems: a dislodged tube a blocked or clogged tube any signs of infection (including redness, swelling, or warmth at the tube site; discharge that's yellow, green, or foul-smelling; fever) excessive bleeding or drainage from the tube site severe abdominal pain lasting ...

  16. Evaluation of App-Based Serious Gaming as a Training Method in Teaching Chest Tube Insertion to Medical Students: Randomized Controlled Trial

    Science.gov (United States)

    Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C

    2018-01-01

    Background The insertion of a chest tube should be as quick and accurate as possible to maximize the benefit and minimize possible complications for the patient. Therefore, comprehensive training and assessment before an emergency situation are essential for proficiency in chest tube insertion. Serious games have become more prevalent in surgical training because they enable students to study and train a procedure independently, and errors made have no effect on patients. However, up-to-date evidence regarding the effect of serious games on performance in procedures in emergency medicine remains scarce. Objective The aim of this study was to investigate the serious gaming approach in teaching medical students an emergency procedure (chest tube insertion) using the app Touch Surgery and a modified objective structural assessment of technical skills (OSATS). Methods In a prospective, rater-blinded, randomized controlled trial, medical students were randomized into two groups: intervention group or control group. Touch Surgery has been established as an innovative and cost-free app for mobile devices. The fully automatic software enables users to train medical procedures and afterwards self-assess their training effort. The module chest tube insertion teaches each key step in the insertion of a chest tube and enables users the meticulous application of a chest tube. In contrast, the module “Thoracocentesis” discusses a basic thoracocentesis. All students attended a lecture regarding chest tube insertion (regular curriculum) and afterwards received a Touch Surgery training lesson: intervention group used the module chest tube insertion and the control group used Thoracocentesis as control training. Participants’ performance in chest tube insertion on a porcine model was rated on-site via blinded face-to-face rating and via video recordings using a modified OSATS tool. Afterwards, every participant received an individual questionnaire for self-evaluation. Here

  17. Ventilation via the 2.4 mm internal diameter Tritube® with cuff – new possibilities in airway management

    DEFF Research Database (Denmark)

    Kristensen, M S; de Wolf, M W P; Rasmussen, L S

    2017-01-01

    BACKGROUND: A small tube may facilitate tracheal intubation and improve surgical access. We describe our initial experience with the Tritube®that is a novel cuffed endotracheal tube with a 2.4 mm internal diameter. METHODS: The Tritube®was used in seven adult Ear-Nose-and Throat surgical patients...... of the intubated airway during oral, pharyngeal, laryngeal or tracheal procedures in adults. This technique has the potential to replace temporary tracheostomy, jet-ventilation or extra-corporal membrane oxygenation in selected patients....

  18. Effects of Fentanyl-lidocaine-propofol and Dexmedetomidine-lidocaine-propofol on Tracheal Intubation Without Use of Muscle Relaxants

    Directory of Open Access Journals (Sweden)

    Volkan Hancı

    2010-05-01

    Full Text Available The aim of this study was to compare the effects of fentanyl or dexmedetomidine when used in combination with propofol and lidocaine for tracheal intubation without using muscle relaxants. Sixty patients with American Society of Anesthesiologists stage I risk were randomized to receive 1 mg/kg dexmedetomidine (Group D, n = 30 or 2 mg/kg fentanyl (Group F, n = 30, both in combination with 1.5 mg/kg lidocaine and 3 mg/kg propofol. The requirement for intubation was determined based on mask ventilation capability, jaw motility, position of the vocal cords and the patient's response to intubation and inflation of the endotracheal tube cuff. Systolic arterial pressure, mean arterial pressure, heart rate and peripheral oxygen saturation values were also recorded. Rate pressure products were calculated. Jaw relaxation, position of the vocal cords and patient's response to intubation and inflation of the endotracheal tube cuff were significantly better in Group D than in Group F (p < 0.05. The intubation conditions were significantly more satisfactory in Group D than in Group F (p = 0.01. Heart rate was significantly lower in Group D than in Group F after the administration of the study drugs and intubation (p < 0.05. Mean arterial pressure was significantly lower in Group F than in Group D after propofol injection and at 3 and 5 minutes after intubation (p < 0.05. After intubation, the rate pressure product values were significantly lower in Group D than in Group F (p < 0.05. We conclude that endotracheal intubation was better with the dexmedetomidine–lidocaine–propofol combination than with the fentanyl–lidocaine–propofol combination. However, side effects such as bradycardia should be considered when using dexmedetomidine.

  19. Randomized controlled trial of the Pentax AWS, Glidescope, and Macintosh laryngoscopes in predicted difficult intubation.

    LENUS (Irish Health Repository)

    Malik, M A

    2009-11-01

    The purpose of this study was to determine the potential for the Pentax AWS and the Glidescope to reduce the difficulty of tracheal intubation in patients at increased risk for difficult tracheal intubation, in a randomized, controlled clinical trial.

  20. Influence of paclitaxel-eluting expandable metallic stent on tissue hyperplasia: an experimental study in a canine tracheal model

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Kim, Jung Sun; Kim, Tae Hyung; Kim, Eun Young; Choi, Won Chan; Woo, Chul Woong; Di, Zhenhai; Song, Ho Young; Yuk, Soon Hong; Lee, Yong Seok

    2005-01-01

    To evaluate the efficacy of a paclitaxel-eluting expandable metallic stent in reducing tissue hyperplasia following stent placement in a canine tracheal model. Nine paclitaxel-eluting stents (drug stent, DS) consisting of a proximal bare part and a distal polyurethane-covered part were placed in the trachea of nine dogs and nine control stents (control stent, CS) were placed in the other nine dogs. The dogs were scheduled to be sacrificed 12 weeks after stent placement. Gross and histological factors, such as epithelial erosion/ulcer, granulation tissue thickness and inflammatory cell infiltration were evaluated after each dog was sacrificed. There were no procedure-related complications or malpositioning of any of the stents. One CS migrated less than eight weeks following stent placement. Four dogs (one DS and three CS dogs) died between three and five weeks following stent placement. Therefore, pathologic specimens were obtained from eight DS and five CS dogs. Epithelial erosion/ulcer or inflammatory cell infiltration was slightly more prominent in the DS cases than in the CS cases, in both the bare part and the covered part. However, the data was not statistically significant. Granulation tissue thickness was lower in the DS cases than in the CS cases in both the bare part (mean, 3.63-mm vs. 4.37-mm) and the covered part (mean, 1.75-mm vs. 2,78 mm), but the data was also statistically insignificant. Although the data was not statistically significant, placement of paclitaxel-eluting expandable metallic stent demonstrates a tendency toward a decrease in granulation tissue thickness in canine tracheal models

  1. Influence of paclitaxel-eluting expandable metallic stent on tissue hyperplasia: an experimental study in a canine tracheal model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Kim, Jung Sun; Kim, Tae Hyung; Kim, Eun Young; Choi, Won Chan; Woo, Chul Woong; Di, Zhenhai; Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yuk, Soon Hong [Hannam University, College of Engineering, Daejeon (Korea, Republic of); Lee, Yong Seok [Wonkwang University College of Medicine, Iksan (Korea, Republic of)

    2005-07-15

    To evaluate the efficacy of a paclitaxel-eluting expandable metallic stent in reducing tissue hyperplasia following stent placement in a canine tracheal model. Nine paclitaxel-eluting stents (drug stent, DS) consisting of a proximal bare part and a distal polyurethane-covered part were placed in the trachea of nine dogs and nine control stents (control stent, CS) were placed in the other nine dogs. The dogs were scheduled to be sacrificed 12 weeks after stent placement. Gross and histological factors, such as epithelial erosion/ulcer, granulation tissue thickness and inflammatory cell infiltration were evaluated after each dog was sacrificed. There were no procedure-related complications or malpositioning of any of the stents. One CS migrated less than eight weeks following stent placement. Four dogs (one DS and three CS dogs) died between three and five weeks following stent placement. Therefore, pathologic specimens were obtained from eight DS and five CS dogs. Epithelial erosion/ulcer or inflammatory cell infiltration was slightly more prominent in the DS cases than in the CS cases, in both the bare part and the covered part. However, the data was not statistically significant. Granulation tissue thickness was lower in the DS cases than in the CS cases in both the bare part (mean, 3.63-mm vs. 4.37-mm) and the covered part (mean, 1.75-mm vs. 2,78 mm), but the data was also statistically insignificant. Although the data was not statistically significant, placement of paclitaxel-eluting expandable metallic stent demonstrates a tendency toward a decrease in granulation tissue thickness in canine tracheal models.

  2. New insights into controlling tube-bundle fouling using alternative amines

    International Nuclear Information System (INIS)

    Turner, C.W.; Klimas, S.J.; Guzonas, D.A.; Frattini, P.L.; Fruzzetti, K.

    2002-01-01

    A volatile amine is added to the secondary heat-transport system of a nuclear power plant to reduce the rate of corrosion and corrosion product transport in the feedwater and to protect steam generator (SG) crevices and materials exposed to steam condensate. Volatility and base strength of the amine at the SG operating temperature are two important considerations when choosing the optimum amine (or mixture of amines) for corrosion control in the steam cycle. Atomic Energy of Canada Limited (AECL) and Electric Power Research Institute (EPRI) have been collaborating in an extensive investigation of the effectiveness of amines at controlling the rate of tube-bundle fouling under SG operating conditions. Tests have been performed using a radiotracing technique in a high-temperature fouling loop facility at Chalk River Laboratories operated by AECL. This investigation has provided new insights into the role played by the amine in determining the rate of tube-bundle fouling in the SG. These insights are being used by AECL and EPRI to develop criteria for the selection of an amine that has optimum properties for both corrosion control and deposit control in the secondary heat transport system. The investigation has found that the rate of tube-bundle fouling is strongly dependent upon the surface chemistry of the corrosion products. For example, the fouling rates of fully oxidized iron oxides, such as hematite and lepidocrocite, are at least an order of magnitude greater than the fouling rate of magnetite under identical operating conditions. The difference is related to the sign of the surface charge on the corrosion products at temperature. The choice of amine for pH-control also influences the fouling rate. This was originally thought to be a surface-charge effect as well, but recent tests have suggested that it is related to the role that the amine plays in governing the rate of deposit consolidation on the heat-transfer surface. Amines that promote a high rate of

  3. Ethical issues in laryngology: tracheal stenting as palliative care.

    Science.gov (United States)

    Kazi, Aasif A; Flowers, W Jeffrey; Barrett, Jeanna M; O'Rourke, Ashli K; Postma, Gregory N; Weinberger, Paul M

    2014-07-01

    To improve understanding of aspects of end-of-life care that may not be intuitive to the otolaryngology community. A comprehensive review of the literature was performed by searching Medline, Embase, and Google Scholar databases. Primary manuscripts' bibliographies were reviewed to identify any nonindexed references. Prospective consultation by means of one-on-one interviews was sought from nonotolaryngology key stakeholders in the areas of hospice nursing care and patient advocacy in order to identify pertinent issues. We identified over 1,000 articles published from 1965 to 2013 on the topic of tracheal stents, as well as over 40,000 on hospice/end-of-life care. Three articles focusing specifically on palliative care and airway stenting were identified, of which three were case reports and none were definitive reviews. There are a number of significant issues and concepts unique to hospice care. These are likely unfamiliar to all except for head and neck oncology-specialized otolaryngologists. An example is that hospice care focuses on quality of life rather than prolongation of life (such as curative surgery). Patients with nonoperable tracheal obstruction from malignancy face an unpleasant demise from suffocation. For those patients, stenting can relieve suffering by restoring airway patency. Airway stenting can be a valid palliative care option, even for terminal patients receiving hospice care, when performed to relieve airway obstruction and improve quality of life. End-of-life ethics is an underdeveloped area of otolaryngology that should be explored. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  4. 21 CFR 872.6570 - Impression tube.

    Science.gov (United States)

    2010-04-01

    ... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6570 Impression tube. (a) Identification. An impression tube is a device consisting of a hollow copper tube intended to take an impression of a single tooth...) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in...

  5. Method of fabricating a poision tube for reactor control rods

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Yasuhiko; Yoshida, Toshimi; Masaoka, Isao; Naruse, Akisuke

    1983-04-28

    A method to unify the neutron absorbing performance, enhance the workability in the insertion of neutron absorber tube and further decrease the stresses acting on the neutron absorber coating tube is described. The neutron absorber coated rod comprising neutron absorbing substance and a metal pipe is fabricated by compressing a metal pipe filled with the neutron absorber. Specifically, neutron absorbing substance such as boron carbide powder or the like is filled in a metal pipe such as made of stainless steel tube by way of vibration packing or the like. Then, after heating the metal pipe, it is applied with compression working such as swaging into a fine tube to increase the packing density of the absorbing substance filled in the pipe to greater than 60% of the theoretical density and completely contacted closely to the inner wall of the pipe. The neutron absorber coated rod thus fabricated can be inserted to an external coating tube with ease at a predetermined gap.

  6. Association of two respiratory congenital anomalies: tracheal diverticulum and cystic adenomatoid malformation of the lung

    International Nuclear Information System (INIS)

    Restrepo, S.; Villamil, M.A.; Rojas, I.C.; Lemos, D.F.; Echeverri, S.; Angarita, M.; Triana, G.

    2004-01-01

    Many associations of congenital anomalies of the respiratory system have been reported, but the combination of tracheal diverticulum and cystic adenomatoid malformation (CCAM) is unique. We present a patient with these two anomalies and analyze their embryological correlation. (orig.)

  7. Sensing system for detection and control of deposition on pendant tubes in recovery and power boilers

    Science.gov (United States)

    Kychakoff, George [Maple Valley, WA; Afromowitz, Martin A [Mercer Island, WA; Hogle, Richard E [Olympia, WA

    2008-10-14

    A system for detection and control of deposition on pendant tubes in recovery and power boilers includes one or more deposit monitoring sensors operating in infrared regions of about 4 or 8.7 microns and directly producing images of the interior of the boiler, or producing feeding signals to a data processing system for information to enable a distributed control system by which the boilers are operated to operate said boilers more efficiently. The data processing system includes an image pre-processing circuit in which a 2-D image formed by the video data input is captured, and includes a low pass filter for performing noise filtering of said video input. It also includes an image compensation system for array compensation to correct for pixel variation and dead cells, etc., and for correcting geometric distortion. An image segmentation module receives a cleaned image from the image pre-processing circuit for separating the image of the recovery boiler interior into background, pendant tubes, and deposition. It also accomplishes thresholding/clustering on gray scale/texture and makes morphological transforms to smooth regions, and identifies regions by connected components. An image-understanding unit receives a segmented image sent from the image segmentation module and matches derived regions to a 3-D model of said boiler. It derives a 3-D structure the deposition on pendant tubes in the boiler and provides the information about deposits to the plant distributed control system for more efficient operation of the plant pendant tube cleaning and operating systems.

  8. Induction of biotransformation enzymes by the carcinogenic air-pollutant 3-nitrobenzanthrone in liver, kidney and lung, after intra-tracheal instillation in rats.

    Science.gov (United States)

    Mizerovská, Jana; Dračínská, Helena; Frei, Eva; Schmeiser, Heinz H; Arlt, Volker M; Stiborová, Marie

    2011-02-28

    3-Nitrobenzanthrone (3-NBA), a carcinogenic air pollutant, was investigated for its ability to induce cytochrome P450 (CYP) 1A1/2 and NAD(P)H:quinone oxidoreductase (NQO1) in liver, kidney and lung of rats treated by intra-tracheal instillation. The organs used were from a previous study performed to determine the persistence of 3-NBA-derived DNA adducts in target and non-target tissues (Bieler et al., Carcinogenesis 28 (2007) 1117-1121, [22]). NQO1 is the enzyme reducing 3-NBA to N-hydroxy-3-aminobenzanthrone (N-OH-3-ABA) and CYP1A enzymes oxidize a human metabolite of 3-NBA, 3-aminobenzanthrone (3-ABA), to yield the same reactive intermediate. 3-NBA and 3-ABA are both activated to species forming DNA adducts by cytosols and/or microsomes isolated from rat lung, the target organ for 3-NBA carcinogenicity, and from liver and kidney. Each compound generated the same five DNA adducts detectable by (32)P-postlabelling. When hepatic cytosols from rats treated with 0.2 or 2mg/kg body weight of 3-NBA were incubated with 3-NBA, DNA adduct formation was 3.2- and 8.6-fold higher, respectively, than in incubations with cytosols from control animals. Likewise, cytosols isolated from lungs and kidneys of rats exposed to 3-NBA more efficiently activated 3-NBA than those of control rats. This increase corresponded to an increase in protein levels and enzymatic activities of NQO1. Incubations of hepatic, pulmonary or renal microsomes of 3-NBA-treated rats with 3-ABA led to an 9.6-fold increase in DNA-adduct formation relative to controls. The highest induction in DNA-adduct levels was found in lung. The stimulation of DNA-adduct formation correlated with expression of CYP1A1/2 induced by the intra-tracheal instillation of 3-NBA. The results demonstrate that 3-NBA induces NQO1 and CYP1A1/2 in livers, lungs and kidneys of rats after intra-tracheal instillation, thereby enhancing its own genotoxic and carcinogenic potential. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Evaluation of App-Based Serious Gaming as a Training Method in Teaching Chest Tube Insertion to Medical Students: Randomized Controlled Trial.

    Science.gov (United States)

    Haubruck, Patrick; Nickel, Felix; Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C

    2018-05-21

    The insertion of a chest tube should be as quick and accurate as possible to maximize the benefit and minimize possible complications for the patient. Therefore, comprehensive training and assessment before an emergency situation are essential for proficiency in chest tube insertion. Serious games have become more prevalent in surgical training because they enable students to study and train a procedure independently, and errors made have no effect on patients. However, up-to-date evidence regarding the effect of serious games on performance in procedures in emergency medicine remains scarce. The aim of this study was to investigate the serious gaming approach in teaching medical students an emergency procedure (chest tube insertion) using the app Touch Surgery and a modified objective structural assessment of technical skills (OSATS). In a prospective, rater-blinded, randomized controlled trial, medical students were randomized into two groups: intervention group or control group. Touch Surgery has been established as an innovative and cost-free app for mobile devices. The fully automatic software enables users to train medical procedures and afterwards self-assess their training effort. The module chest tube insertion teaches each key step in the insertion of a chest tube and enables users the meticulous application of a chest tube. In contrast, the module "Thoracocentesis" discusses a basic thoracocentesis. All students attended a lecture regarding chest tube insertion (regular curriculum) and afterwards received a Touch Surgery training lesson: intervention group used the module chest tube insertion and the control group used Thoracocentesis as control training. Participants' performance in chest tube insertion on a porcine model was rated on-site via blinded face-to-face rating and via video recordings using a modified OSATS tool. Afterwards, every participant received an individual questionnaire for self-evaluation. Here, trainees gave information about their

  10. Disinfection of Biofilms in Tubes with Ultraviolet Light

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja

    2009-01-01

    Bacterial biofilms on long-term catheters are a major source of infection. We demonstrate here the potential of UVC light emitting diodes (LED) for disinfection purposes in catheter like tubes contaminated with biofilm. We show that UVC Light propagation is possible through teflon tubes using...... to a flow system and biofilms were produced during a three day period. Tubes in lengths of 10 cm (FEP teflon) were contaminated. Tubes for control and for UVC treatment were contaminated in parallel. The control and UVC treated tubes were both filled with a 20 % NaCl solution during the UVC treatment time...

  11. An approach to tracheostomy in a patient with an expandable metallic tracheal stent.

    Science.gov (United States)

    Madden, Brendan P; Sheth, Abhijat

    2005-09-01

    With increasing use of expandable metallic stents to manage patients with a variety of endobronchial pathologies, some will have a subsequent need for tracheostomy insertion. We describe a successful technique to insert a tracheostomy using rigid and fibre-optic bronchoscopy in a patient who had an 8 cm expandable metallic tracheal stent deployed previously on account of tracheomalacia.

  12. Simultaneous Chronic Invasive Fungal Infection and Tracheal Fungus Ball Mimicking Cancer in an Immunocompetent Patient

    Directory of Open Access Journals (Sweden)

    Erdoğan Çetinkaya

    2016-01-01

    Full Text Available Fungal infections of the lung are uncommon and mainly affect people with immune deficiency. There are crucial problems in the diagnosis and treatment of this condition. Invasive pulmonary aspergillosis and candidiasis are the most common opportunistic fungal infections. Aspergillus species (spp. are saprophytes molds that exist in nature as spores and rarely cause disease in immunocompetent individuals. In patients with immune deficiency or chronic lung disease, such as cavitary lung disease or bronchiectasis, Aspergillus may cause a variety of aspergillosis infections. Here we present a case of a 57-year-old patient without immunodeficiency or chronic lung disease who was diagnosed with endotracheal fungus ball and chronic fungal infection, possibly due to Aspergillus. Bronchoscopic examination showed a paralyzed right vocal cord and vegetating mass that was yellow in color, at the posterior wall of tracheal lumen. After 3 months, both the parenchymal and tracheal lesions were completely resolved.

  13. Effectiveness of bait tubes for brown treesnake control on Guam

    Science.gov (United States)

    Lardner, B.; Savidge, J.A.; Rodda, G.H.; Reed, R.N.; Yackel Adams, A.A.; Clark, C.S.

    2011-01-01

    A bait tube is a device with which a toxicant inserted in a dead mouse (Mus musculus) can be delivered to invasive brown treesnakes (Boiga irregularis) with low risk of non-target bait take. We tested two bait tube designs in a 5ha snake enclosure where the identity of virtually every snake is known. Instead of using toxicants, we implanted radio transmitters in small (6.6±1.4 g) and large (21.8±2.9 g) bait mice. Knowing all snakes present in the population allowed us to characterize not only covariates of snakes taking bait, but also those of snakes evading our mock control effort, and if snake covariates interacted with any design variable in determining targeting rate. Tube design had no effect on take rate. Snake snout-vent length was a strong predictor of success: none of the 29 snakes smaller than 843 mm took any bait, while the 126 snakes ≥843 mm were responsible for a total of 164 bait takes. The smallest of these snakes were able to ingest small and large mice, but tended to consume small bait at a higher rate than large bait. The main reason for our failure to target smallest snakes appears not to be gape limitation, but rather that small snakes prefer other prey (lizards). The time it takes a snake to grow from the size threshold observed to the size of maturation has implications for the interval between discrete efforts using toxic bait. Targeting all snakes before reproduction can occur is highly desirable; otherwise, a new cohort of refractory snakes may enter the population.

  14. The Effect of Endotracheal Inflation Technique on Endotracheal Cuff Pressure

    Science.gov (United States)

    1999-10-01

    had upon tracheal wall blood flow of anesthetized dogs . This study found that low-volume, high-pressure cuffs required 320 to 360 mm Hg of pressure to...Som, P., Khilnani, M., Keller, R., & Som, M. (1972). Tracheal stenosis secondary to cuffed tubes. Mount Siai Journal of Medicine, 40, 652-665

  15. Gel spinning of silk tubes for tissue engineering

    Science.gov (United States)

    Lovett, Michael; Cannizzaro, Christopher; Vunjak-Novakovic, Gordana; Kaplan, David L.

    2011-01-01

    Tubular vessels for tissue engineering are typically fabricated using a molding, dipping, or electrospinning technique. While these techniques provide some control over inner and outer diameters of the tube, they lack the ability to align the polymers or fibers of interest throughout the tube. This is an important aspect of biomaterial composite structure and function for mechanical and biological impact of tissue outcomes. We present a novel aqueous process system to spin tubes from biopolymers and proteins such as silk fibroin. Using silk as an example, this method of winding an aqueous solution around a reciprocating rotating mandrel offers substantial improvement in the control of the tube properties, specifically with regard to winding pattern, tube porosity, and composite features. Silk tube properties are further controlled via different post-spinning processing mechanisms such as methanol-treatment, air-drying, and lyophilization. This approach to tubular scaffold manufacture offers numerous tissue engineering applications such as complex composite biomaterial matrices, blood vessel grafts and nerve guides, among others. PMID:18801570

  16. Repopulation of denuded tracheal grafts with alveolar type II cells

    International Nuclear Information System (INIS)

    Johnson, N.F.

    1988-01-01

    Repopulation of denuded heterotopic tracheal grafts with populations of specific epithelial cell types is one approach to study the differentiation potential of various cell types. This technique has been adopted to delineate the differentiation pathways of alveolar type II cells isolated from rat lungs. Under the conditions of this experiment, the reestablished epithelial lining was alveolar-like, however, ultrastructural analysis of the cells showed them to be like Clara cells. These preliminary results suggest that the secretary cells of the lung parenchyma and terminal airways may share a common ancestry. (author)

  17. On the Morphological Description of Tracheal and Esophageal Displacement and Its Phylogenetic Distribution in Avialae

    Science.gov (United States)

    Klingler, Jeremy J.

    2016-01-01

    This research examines the evolution and phylogenetic distribution of a peculiar and often overlooked character seen in birds, herein called tracheal and esophageal displacement. Tracheal and esophageal displacement refers to an asymmetrically situated trachea and/or esophagus along the length of the neck. This contrasts with what would be perceived as the “normal” (midsagittal) placement of these organs, wherein the two organs are situated along the ventral midline of the neck with no deviation. A total of forty-two bird species were examined (thirty-six of which came from dissections whereas six came from comments from previous literature or personal observations), as well as turtles, lizards, crocodylians, and mammals. This study found that essentially all birds have a laterally displaced trachea and/or esophagus. Lizards and mammals were seen to have normal, midsagittally placed tracheae and esophagi. Crocodylians were interesting in that alligators were defined by a normally situated trachea and esophagus whereas some crocodiles were characterized by displacement. In birds, the displacement may occur gradually along the neck, or it may happen immediately upon exiting the oropharynx. Displacement of these organs in birds is the result of a heavily modified neck wherein muscles that restrict mobility of the trachea and esophagus in lizards, alligators, and mammals (e.g., m. episternocleidomastoideus, m. omohyoideus, and m. sternohyoideus) no longer substantially restrict positions of the trachea and esophagus in birds. Rather, these muscles are modified in ways which may assist with making tracheal movements. The implications of this study may provide interesting insights for future comparisons in extinct taxa. PMID:27648952

  18. On the Morphological Description of Tracheal and Esophageal Displacement and Its Phylogenetic Distribution in Avialae.

    Directory of Open Access Journals (Sweden)

    Jeremy J Klingler

    Full Text Available This research examines the evolution and phylogenetic distribution of a peculiar and often overlooked character seen in birds, herein called tracheal and esophageal displacement. Tracheal and esophageal displacement refers to an asymmetrically situated trachea and/or esophagus along the length of the neck. This contrasts with what would be perceived as the "normal" (midsagittal placement of these organs, wherein the two organs are situated along the ventral midline of the neck with no deviation. A total of forty-two bird species were examined (thirty-six of which came from dissections whereas six came from comments from previous literature or personal observations, as well as turtles, lizards, crocodylians, and mammals. This study found that essentially all birds have a laterally displaced trachea and/or esophagus. Lizards and mammals were seen to have normal, midsagittally placed tracheae and esophagi. Crocodylians were interesting in that alligators were defined by a normally situated trachea and esophagus whereas some crocodiles were characterized by displacement. In birds, the displacement may occur gradually along the neck, or it may happen immediately upon exiting the oropharynx. Displacement of these organs in birds is the result of a heavily modified neck wherein muscles that restrict mobility of the trachea and esophagus in lizards, alligators, and mammals (e.g., m. episternocleidomastoideus, m. omohyoideus, and m. sternohyoideus no longer substantially restrict positions of the trachea and esophagus in birds. Rather, these muscles are modified in ways which may assist with making tracheal movements. The implications of this study may provide interesting insights for future comparisons in extinct taxa.

  19. [Complications and the management of fully covered retrievable metal stent placement in benign tracheal stenosis].

    Science.gov (United States)

    Wang, Zheng-yu; Wang, Yong-li; Chen, Guang-li; Liang, Xi-hong; Wang, Zhen-chang; Ma, Jian-zhong; Wu, Guang-zhong; Zhang, Xiao-ping

    2012-11-01

    To study complications and the management of the use of covered retrievable expandable metallic stents in the treatment of benign tracheal stenosis. Fully covered retrievable metal stents were placed in 21 patients with benign tracheal stenosis. Stent-related complications and the management were reviewed and analysed. Twenty-eight fully covered retrievable metallic stents were successfully placed fluoroscopically in 21 patients. Stents were removed 4 - 12 months [mean (5.5 ± 2.2) mouths] after placement in all patients. Stent-related complications included granulation tissue (n = 18), stent migration (n = 4), stent expectoration (n = 2), halitosis (n = 8), mucous retention (n = 21) and mucus plugging (n = 1). Granulation tissue was removed with a carbon dioxide laser in 2 patients. Stents were replaced for 2 times and 3 times respectively in 2 patients after stent migration and stent expectoration. An additional stent was placed in 2 patients after stent migration. Symptom of halitosis was relieved after prolonged course of systemic antibiotics treatment in 8 patients. Symptom of mucous retention was relieved with nebulized saline and N-acetylcysteine saline inhalation. Mucous plug was expelled after severe coughing after suctioning using an aspirator in one patient. There were statistically significant differences in stricture diameter, rank of tachypnea and pulmonary function (FEV(1)) in all 21 patients before stent insertion and after stents removal. No patient has experienced recurrence during the follow-up period of 1 - 36 months [mean (23.2 ± 8.0) months]. Fully covered retrievable metallic stent may be a safe and effective in benign tracheal stenosis. Stent-related complications may be effectively managed.

  20. Incidence of tracheal aspiration in tracheotomized patients in use of mechanical ventilation Incidência de aspiração traqueal em pacientes traqueostomizados em uso de ventilação mecânica

    Directory of Open Access Journals (Sweden)

    Mariana de Almeida Simão

    2009-12-01

    Full Text Available CONTEXT: Many patients in use of mechanical ventilation show clinical complications due to tracheal aspiration. Assessment and early methods are necessary, so that preventive and safety measures apply to this patients OBJECTIVE: To study the incidence of tracheal aspiration of saliva in tracheotomized patients treated in intensive care unit using two modes of mechanical ventilation and with different sedation levels. METHOD: Prospective study with 14 tracheotomized non-neurological patients using mechanical ventilation. The sample was divided into two groups based on ventilation mode: pressure support ventilation and pressure controlled ventilation. Those two groups were subdivided into two others according to sedation level. The speech pathology evaluation was completed via the blue dye test in order to analyze the incidence of tracheal aspiration of saliva. RESULTS: Sedation levels and mechanical ventilation time related to tracheal aspiration were not statistically significant in this study. On the other hand, ventilation mode and tracheal aspiration showed statistical significance, and there was a higher incidence of tracheal aspiration in the pressure controlled ventilation mode. CONCLUSION: It was possible to observe a significant relationship between tracheal aspiration incidence and pressure controlled ventilation mode, which means the inclusion of those patients in the risk group for oropharyngeal dysphagia and their insertion in prevention protocols. The relationship between tracheal aspiration and sedation level, as well as tracheal aspiration and mechanical ventilation, were not statistically significant in this sample, needing further research.CONTEXTO: Muitos pacientes em uso de ventilação mecânica apresentam complicações clínicas por apresentarem aspiração traqueal. Métodos de avaliação e detecção precoce são necessários para que medidas preventivas e de segurança se estabeleçam nessa população. OBJETIVO

  1. Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq and Macintosh laryngoscope.

    LENUS (Irish Health Repository)

    Maharaj, C H

    2006-07-01

    Direct laryngoscopic tracheal intubation is taught to many healthcare professionals as it is a potentially lifesaving procedure. However, it is a difficult skill to acquire and maintain, and, of concern, the consequences of poorly performed intubation attempts are potentially serious. The Airtraq Laryngoscope is a novel intubation device which may possess advantages over conventional direct laryngoscopes for use by novice personnel. We conducted a prospective trial with 40 medical students who had no prior airway management experience. Following brief didactic instruction, each participant took turns in performing laryngoscopy and intubation using the Macintosh and Airtraq devices under direct supervision. Each student was allowed up to three attempts to intubate in three laryngoscopy scenarios using a Laerdal Intubation Trainer and one scenario in a Laerdal SimMan Manikin. They then performed tracheal intubation of the normal airway a second time to characterise the learning curve for each device. The Airtraq provided superior intubating conditions, resulting in greater success of intubation, particularly in the difficult laryngoscopy scenarios. In both easy and simulated difficult laryngoscopy scenarios, the Airtraq decreased the duration of intubation attempts, reduced the number of optimisation manoeuvres required, and reduced the potential for dental trauma. The Airtraq device showed a rapid learning curve and the students found it significantly easier to use. The Airtraq appears to be a superior device for novice personnel to acquire the skills of tracheal intubation.

  2. Controlled Thermal-Mechanical Processing of Tubes and Pipes for Enhanced Manufacturing and Performance

    Energy Technology Data Exchange (ETDEWEB)

    Kolarik, Robert V.

    2005-11-11

    The Alloy Steel Business of The Timken Company won an award for the controlled thermo-mechanical processing (CTMP) project and assembled a strong international public/private partnership to execute the project. The premise of the CTMP work was to combine Timken's product understanding with its process expertise and knowledge of metallurgical and deformation fundamentals developed during the project to build a predictive process design capability. The CTMP effort succeeded in delivering a pc-based capability in the tube optimization model, with a virtual pilot plant (VPP) feature to represent the desired tube making process to predict the resultant microstructure tailored for the desired application. Additional tasks included a system for direct, online measurement of grain size and demonstration of application of CTMP via robotically enhanced manufacturing.

  3. Use of nitinol self-expandable stents in 26 dogs with tracheal collapse.

    Science.gov (United States)

    Beranek, J; Jaresova, H; Rytz, U

    2014-02-01

    A study was designed to describe a novel approach to the treatment of tracheal collapse (TC) in dogs using self-expandable nitinol stents. Medical records were reviewed retrospectively for 26 client owned dogs in which nitinol stents were deployed. The entire length of trachea was supported independently of the extent of TC. Two overlapping stents were used instead of one in cases where one stent was not spanning the entire trachea adequately. The diameter of the cranial radiolucent portion of trachea, just behind the cricoid cartilage, was measured as a specific landmark to select the appropriate size of the stent. Two self-expandable nitinol stents were inserted in 9 of 26 dogs; the trachea in the rest of the cases was supported with only one stent. A follow up tracheoscopy was performed in 10 of 26 cases with recurrent clinical signs. Secondary tracheal stenosis in these cases was caused by stent fracture, granuloma or excessive stent shortening. Additional stents were placed successfully to expand the stenotic lumen. A support of the entire trachea may decrease risk of nitinol fracture at the end of the implant. Long term clinical improvement (25 of 26 dogs, 96 %) is comparable with the results of other studies.

  4. Anesthetic and Airways Management of a Dog with Severe Tracheal Collapse during Intraluminal Stent Placement

    Directory of Open Access Journals (Sweden)

    M. Argano

    2013-01-01

    Full Text Available This case report describes the anesthetic and airways management of a dog affected by 4th degree tracheal collapse and undergoing endoscope-guided intraluminal stent placement. After premedication with acepromazine and butorphanol, general anesthesia was induced with propofol and maintained with intravenous propofol and butorphanol in constant rate infusion. During intraluminal stent placement, oxygen was supplemented by means of a simple and inexpensive handmade device, namely, a ureteral catheter inserted into the trachea and connected to an oxygen source, which allowed for the maintenance of airways’ patency and adequate patient’s oxygenation, without decreasing visibility in the surgical field or interfering with the procedure. The use of the technique described in the present paper was the main determinant of the successful anesthetic management and may be proposed for similar critical cases in which surgical manipulation of the tracheal lumen, which may potentially result in hypoxia by compromising airways patency, is required.

  5. Managing a chest tube and drainage system.

    Science.gov (United States)

    Durai, Rajaraman; Hoque, Happy; Davies, Tony W

    2010-02-01

    Intercostal drainage tubes (ie, chest tubes) are inserted to drain the pleural cavity of air, blood, pus, or lymph. The water-seal container connected to the chest tube allows one-way movement of air and liquid from the pleural cavity. The container should not be changed unless it is full, and the chest tube should not be clamped unnecessarily. After a chest tube is inserted, a nurse trained in chest-tube management is responsible for managing the chest tube and drainage system. This entails monitoring the chest-tube position, controlling fluid evacuation, identifying when to change or empty the containers, and caring for the tube and drainage system during patient transport. This article provides an overview of indications, insertion techniques, and management of chest tubes. Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  6. Extrinsic tracheal compression caused by scoliosis of the thoracic spine and chest wall degormity: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Kyong min Sarah; Lee, Bae Young; Kim, Hyeon Sook; Song, Kyung Sup; Kang, Hyeon Hul; Lee, Sang Haak; Moon, Hwa Sik [St. Paul' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2014-05-15

    Extrinsic airway compression due to chest wall deformity is not commonly observed. Although this condition can be diagnosed more easily with the help of multidetector CT, the standard treatment method has not yet been definitely established. We report a case of an eighteen-year-old male who suffered from severe extrinsic tracheal compression due to scoliosis and straightening of the thoracic spine, confirmed on CT and bronchoscopy. The patient underwent successful placement of tracheal stent but later died of bleeding from the tracheostomy site probably due to tracheo-brachiocephalic artery fistula. We describe the CT and bronchoscopic findings of extrinsic airway compression due to chest wall deformity as well as the optimal treatment method, and discuss the possible explanation for bleeding in the patient along with review of the literature.

  7. Extrinsic tracheal compression caused by scoliosis of the thoracic spine and chest wall degormity: A case report

    International Nuclear Information System (INIS)

    Baek, Kyong min Sarah; Lee, Bae Young; Kim, Hyeon Sook; Song, Kyung Sup; Kang, Hyeon Hul; Lee, Sang Haak; Moon, Hwa Sik

    2014-01-01

    Extrinsic airway compression due to chest wall deformity is not commonly observed. Although this condition can be diagnosed more easily with the help of multidetector CT, the standard treatment method has not yet been definitely established. We report a case of an eighteen-year-old male who suffered from severe extrinsic tracheal compression due to scoliosis and straightening of the thoracic spine, confirmed on CT and bronchoscopy. The patient underwent successful placement of tracheal stent but later died of bleeding from the tracheostomy site probably due to tracheo-brachiocephalic artery fistula. We describe the CT and bronchoscopic findings of extrinsic airway compression due to chest wall deformity as well as the optimal treatment method, and discuss the possible explanation for bleeding in the patient along with review of the literature.

  8. Comparison of Pentax-AWS Airwayscope and Glidescope for Infant Tracheal Intubation by Anesthesiologists during Cardiopulmonary Arrest Simulation: A Randomized Crossover Trial

    Directory of Open Access Journals (Sweden)

    Shunsuke Fujiwara

    2015-01-01

    Full Text Available Background. Recent guidelines for infant cardiopulmonary resuscitation emphasize that all rescuers should minimize interruption of chest compressions, even for endotracheal intubation. We compared the utility of the Pentax-AWS Airwayscope (AWS with the Glidescope (GS during chest compressions on an infant manikin. Methods. Twenty-four anesthesiologists with more than two years of experience performed tracheal intubation on an infant manikin using the AWS and GS, with or without chest compressions. Results. In GS trials, none of the participants failed without compressions, while three failed with compressions. In AWS trials, all participants succeeded regardless of chest compressions. Intubation time was significantly longer with chest compressions with the GS (P<0.05, but not with the AWS. Difficulty of operation on a visual analog scale (VAS for laryngoscopy did not increase significantly with chest compressions with either the GS or the AWS, while the VAS for tube passage through the glottis increased with compressions with the GS, but not with the AWS. Conclusion. We conclude that in infant simulations managed by anesthesiologists, the AWS performed better than the GS for endotracheal intubation with chest compressions.

  9. Time domain models for damping-controlled fluidelastic instability forces in multi-span tubes with loose supports

    International Nuclear Information System (INIS)

    Hassan, M.A.; Rogers, R.J.; Gerber, A.G.

    2009-01-01

    This paper presents simulations of a loosely supported multi-span tube subjected to turbulence and fluidelastic instability forces. Several time-domain fluid force models simulating the damping controlled fluidelastic instability mechanism in tube arrays have been presented. These models include the negative damping model based on the Connors equation, fluid force coefficient-based models (Chen and Tanaka and Takahara), and two semi-analytical models (Price and Paidoussis; and Lever and Weaver) were implemented in an in-house finite code. Time domain modeling challenges for each of these theories were discussed. The implemented models were validated against available experimental data. The linear simulations showed that the Connors-equation based model exhibits the most conservative prediction of the critical flow velocity when the recommended design values for the Connors equation were used. The models were then utilized to simulate the nonlinear response of a three-span cantilever tube in a square lattice bar support subjected to air crossflow. The tube was subjected to a single-phase flow passing over one of the tube's spans. For each of these models the flow velocity and the support clearance were varied. Special attention was paid to the tube/support interaction parameters that affect wear, such as impact forces, contact ratio, and normal work rate. As the prediction of the linear threshold varies depending on the utilized model, the nonlinear response also differs. The investigated models exhibit similar response characteristics for the impact force, tip lift response, and work rate. Simulation results show that the Connors-based model underestimates the response and the tube/support interaction parameters for the loose support case. (author)

  10. SG tube identification

    International Nuclear Information System (INIS)

    Hoogstraten, P. van

    1994-01-01

    A ''Tracker'' system is described which is designed to identify any tube in a reactor steam generator quickly and safely. Occupational radiation doses to maintenance workers are reduced by using a Tracker and emergency down times are shortened. The system employs a television camera and light source in a stainless steel box with a large window. Both the camera and spotlight can be panned and tilted to reach any point on the tubesheet and are remotely controlled. An operator at a safe working distance can identify any tube visible on a real time video by comparison with the tubesheet pattern stored earlier in the computer memory. The identified tube can then be spotlighted and dealt with quickly by a maintenance worker inside the channel head. (UK)

  11. Epigenetic profiles in children with a neural tube defect; a case-control study in two populations.

    Directory of Open Access Journals (Sweden)

    Lisette Stolk

    Full Text Available Folate deficiency is implicated in the causation of neural tube defects (NTDs. The preventive effect of periconceptional folic acid supplement use is partially explained by the treatment of a deranged folate-dependent one carbon metabolism, which provides methyl groups for DNA-methylation as an epigenetic mechanism. Here, we hypothesize that variations in DNA-methylation of genes implicated in the development of NTDs and embryonic growth are part of the underlying mechanism. In 48 children with a neural tube defect and 62 controls from a Dutch case-control study and 34 children with a neural tube defect and 78 controls from a Texan case-control study, we measured the DNA-methylation levels of imprinted candidate genes (IGF2-DMR, H19, KCNQ1OT1 and non-imprinted genes (the LEKR/CCNL gene region associated with birth weight, and MTHFR and VANGL1 associated with NTD. We used the MassARRAY EpiTYPER assay from Sequenom for the assessment of DNA-methylation. Linear mixed model analysis was used to estimate associations between DNA-methylation levels of the genes and a neural tube defect. In the Dutch study group, but not in the Texan study group we found a significant association between the risk of having an NTD and DNA methylation levels of MTHFR (absolute decrease in methylation of -0.33% in cases, P-value = 0.001, and LEKR/CCNL (absolute increase in methylation: 1.36% in cases, P-value = 0.048, and a borderline significant association for VANGL (absolute increase in methylation: 0.17% in cases, P-value = 0.063. Only the association between MTHFR and NTD-risk remained significant after multiple testing correction. The associations in the Dutch study were not replicated in the Texan study. We conclude that the associations between NTDs and the methylation of the MTHFR gene, and maybe VANGL and LEKKR/CNNL, are in line with previous studies showing polymorphisms in the same genes in association with NTDs and embryonic development

  12. Reduction in degree of absorber-cladding mechanical interaction by shroud tube in control rods for the fast reactor

    International Nuclear Information System (INIS)

    Donomae, Takako; Katsuyama, Kozo; Tachi, Yoshiaki; Maeda, Koji; Yamamoto, Masaya; Soga, Tomonori

    2011-01-01

    Research and development of a long-life control rod for fast reactors is being conducted at Joyo. One of the challenges in developing a long-life control rod is the restraint of absorber-cladding mechanical interaction (ACMI). First, a helium-bonding rod was selected as a control rod for the experimental fast reactor Joyo, which is the first liquid metal fast reactor in Japan. Its lifetime was limited by ACMI, which is induced by the swelling and relocation of B 4 C pellets. To restrain ACMI, a shroud tube was inserted into the gap between the B 4 C pellets and the cladding tube. However, once B 4 C pellets cracked and broke into small fragments, relocation occurred. After this, the narrow gap closed immediately as the degree of B 4 C pellet swelling increased. To solve this problem, the gap was widened during design, and sodium was selected as the bonding material instead of helium to restrain the increase in pellet temperature. Irradiation testing of the modified sodium-bonding control rod confirmed that ACMI would be restrained by the shroud tube regardless of the occurrence of B 4 C pellet relocation. As a result of these improvements, the estimated lifetime of the control rod at Joyo was doubled. In this paper, the results of postirradiation examination are reported. (author)

  13. Successful Management of Airway Emergency in a Patient with Esophageal Cancer

    Directory of Open Access Journals (Sweden)

    Samina Park

    2015-05-01

    Full Text Available A 60-year-old man with advanced esophageal cancer was admitted for surgical placement of a feeding jejunostomy tube before commencement of chemoradiotherapy. His esophageal cancer had directly invaded the posterior tracheal wall, inducing a nearly total obstruction of the distal trachea. On the day before the surgery, respiratory failure developed due to tumor progression and tracheal edema. Tracheal intubation and mechanical ventilation were attempted without success. Application of veno-venous extracorporeal membrane oxygenation (ECMO corrected the patient’s respiratory acidosis and relieved his dyspnea. With full ECMO support, he underwent tracheal stent insertion. Two hours later, he was weaned from ECMO support uneventfully. This was a successful case of tracheal stenting for airway obstruction under rescue veno-venous ECMO.

  14. Production and quality control of fuel cladding tubes for LWRs

    International Nuclear Information System (INIS)

    Matsuda, Katsuhiko; Hagi, Shigeki; Anada, Hiroyuki; Abe, Hideaki; Hyodo, Shigetoshi

    1994-01-01

    This paper reviews the recent fabrication technology and corrosion resistance study of fuel cladding tubes for LWRs conducted by Sumitomo Metal Industries Ltd. started the research on zircaloy in 1957. In 1980, the factory exclusively for the production of cladding tubes was founded, and the mass production system on full scale was established. Thereafter, the various improvement of the production technology, the development of new products, and the heightening of the performance mainly on the corrosion resistance have been tested and studied. Recently, the works in the production processes were almost automated, and the installation of the production lines advanced, and the stabilization of product quality and the rationalization of costs are promoted. Moreover, the development of the zircaloy cladding tubes having high corrosion resistance has been advanced to cope with the long term cycle operation of LWRs hereafter. The features of zircaloy cladding tubes, the manufacturing processes, the improvement of the manufacturing technology, the improvement of the corrosion resistance and so on are reported. (K.I.)

  15. The single chest tube versus double chest tube application after pulmonary lobectomy: A systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Xuefei Zhang

    2016-01-01

    Conclusion: Compared with the double chest tube, the single chest tube significantly decreases amount of drainage, duration of chest tube drainage, pain score, the number of patients who need thoracentesis, and cost. Although there is convincing evidence to confirm the results mentioned herein, they still need to be confirmed by large-sample, multicenter, randomized, controlled trials.

  16. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  17. Esophageal trachealization: A feature of eosinophilic esophagitis

    International Nuclear Information System (INIS)

    AlHussaini, Abdulrahman A; Semaan, Toufic; ElHag, Imad A

    2009-01-01

    Eosinophilic esophagitis (EE) is an inflammatory condition characterized by intense eosinophilic infiltration of the esophagus. EE is frequently misdiagnosed as gastroesophageal reflux disease. Here, we present a child with EE and a characteristic endoscopic finding, r inged esophagus . An 11-year-old Saudi boy presented with dysphagia for 1 year. He had experienced an intermittent sensation of solid food sticking in his chest, which was relieved by drinking liquids. A barium swallow excluded anatomical causes of dysphagia, but revealed multiple-ringed esophagus. Endoscopy showed a furrowing and trachealizing appearance of the entire esophagus. Hisologically, extensive eosinophilic infiltration was a feature in biopsies obtained from the esophagus. The child responded well to a 2-month course of inhaled fluticasone. Symptoms recurred 3 months after discontinuation of therapy, which necessitated resumption of inhaled fluticasone. The endoscopic appearance of multiple esophageal rings should raise suspicion of EE and be confirmed by esophageal biopsies. (author)

  18. Fabrication of seamless calandria tubes

    International Nuclear Information System (INIS)

    Saibaba, N.; Phanibabu, C.; Bhaskara Rao, C.V.; Kalidas, R.; Ganguly, C.

    2002-01-01

    Full text: Calandria tube is a large diameter, thin walled zircaloy-4 tube and is an important structural component of PHWR type of reactors. These tubes are lifetime components and remain during the full life of the reactor. Calandria tubes are classified as extremely thin walled tubes with a diameter to wall thickness ratio of around 96. Such thin walled tubes are conventionally produced by seam welded route comprising of extrusion of slabs followed by a series of hot and rolling passes, shaping into O-shape and eventual welding. An alternative and superior method of fabricating the calandria tubes, the seamless route, has been developed, which involves hot extrusion of mother blanks followed by three successive cold pilger reductions. Eccentricity correction of the extruded blanks is carried out on a special purpose grinding equipment to bring the wall thickness variation within permissible limits. Predominant wall thickness reductions are given during cold pilgering to ensure high Q-factor values. The texture in the finished tubes could be closely, controlled with an average f r value of 0.65. Pilgering parameters and tube guiding system have been specially designed to facilities rolling of thin walled tubes. Seamless calandria tubes have distinct advantages over welded tubes. In addition to the absence of weld, they are dimensionally more stable, lighter in weight and possess uniform grains with superior grain size. The cycle time from billet to finished product is substantially reduced and the product is amenable to high level of quality assurance. The most significant feature of the seamless route is its material recovery over welded route. Residual stresses measured in the tubes indicate that these are negligible and uniform along the length of the tube. In view of their superior quality, the first charge of seamless calandria tubes will be rolled into the first 500 MWe Pressurised Heavy Water Reactor at Tarapur

  19. Clinical tube weaning supported by hunger provocation in fully-tube-fed children.

    Science.gov (United States)

    Hartdorff, Caroline M; Kneepkens, C M Frank; Stok-Akerboom, Anita M; van Dijk-Lokkart, Elisabeth M; Engels, Michelle A H; Kindermann, Angelika

    2015-04-01

    Children with congenital malformations, mental retardation, and complex early medical history frequently have feeding problems. Although tube feeding is effective in providing the necessary energy and nutrients, it decreases the child's motivation to eat and may lead to oral aversion. In this study, we sought to confirm our previous results, showing that a multidisciplinary clinical hunger provocation program may lead to quick resumption of oral feeding. In a crossover study, 22 children of 9 to 24 months of age who were fully dependent on tube feeding were randomly assigned to one of two groups: group A, intervention group (2-week multidisciplinary clinical hunger provocation program); and group B, control group (4-week outpatient treatment by the same multidisciplinary team). Patients failing one treatment were reassigned to the other treatment group. Primary outcome measures were at least 75% orally fed at the conclusion of the intervention and fully orally fed and gaining weight 6 months after the intervention. In group A, 9/11 patients were successfully weaned from tube feeding (2 failures: 1 developed ulcerative colitis, 1 drop-out). In group B, only 1 patient was weaned successfully; 10/11 were reassigned to the clinical hunger provocation program, all being weaned successfully. Six months after the intervention, 1 patient had to resume tube feeding. In total, in the control group, 1/11 (9%) was weaned successfully as compared with 18/21 (86%) in the hunger provocation group (P hunger provocation is an effective short-term intervention for weaning young children from tube feeding.

  20. Effects of preoperative irradiation on primary tracheal anastomosis

    International Nuclear Information System (INIS)

    Tsubota, N.; Simpson, W.J.; Van Nostrand, A.W.P.; Pearson, F.G.

    1975-01-01

    Preoperative radiotherapy was used in the management of selected patients with cancer of the lung or trachea who might subsequently require segmental resection of bronchus or trachea and reconstruction by primary anastomosis. This study was designed to determine the effects of varying dosages of preoperative irradiation on anastomotic healing. Two rings were resected from the cervical trachea of 20 dogs following irradiation with varying doses of cesium. There were no important adverse effects on healing of the trachea or adjacent organs in dogs receiving up to 3,500 rads. All dogs receiving a higher dose than this developed some anastomotic stenosis, which was severe in 6 of 8 animals. Similar adverse effects were observed in 2 patients managed by preoperative radiotherapy (4,000 rads in three weeks) and tracheal resection with primary anastomosis

  1. Effects of preoperative irradiation on primary tracheal anastomosis

    Energy Technology Data Exchange (ETDEWEB)

    Tsubota, N.; Simpson, W.J.; Van Nostrand, A.W.P.; Pearson, F.G.

    1975-08-01

    Preoperative radiotherapy was used in the management of selected patients with cancer of the lung or trachea who might subsequently require segmental resection of bronchus or trachea and reconstruction by primary anastomosis. This study was designed to determine the effects of varying dosages of preoperative irradiation on anastomotic healing. Two rings were resected from the cervical trachea of 20 dogs following irradiation with varying doses of cesium. There were no important adverse effects on healing of the trachea or adjacent organs in dogs receiving up to 3,500 rads. All dogs receiving a higher dose than this developed some anastomotic stenosis, which was severe in 6 of 8 animals. Similar adverse effects were observed in 2 patients managed by preoperative radiotherapy (4,000 rads in three weeks) and tracheal resection with primary anastomosis.

  2. Effects of perfluorooctane sulfonate on tracheal ciliary beating frequency in mice

    International Nuclear Information System (INIS)

    Matsubara, Eriko; Nakahari, Takashi; Yoshida, Hideyo; Kuroiwa, Toshihiko; Harada, Kouji H.; Inoue, Kayoko; Koizumi, Akio

    2007-01-01

    Perfluorooctane sulfonate (PFOS) is one of the emerging persistent organic pollutants, ubiquitously found in the global environment, even in human serum. PFOS has been reported to perturb Ca 2+ homeostasis in Paramecium, cardiomyocytes and neurons. Since ciliary beat frequency (CBF) in the trachea is known to be increased by cytoplasmic Ca 2+ elevation, the effects of PFOS on CBF were evaluated in a slice preparation using video-enhanced contrast microscopy. PFOS increased CBF by 11% (P 2+ concentration ([Ca 2+ ] i ) in mouse tracheal ciliary cells. In Ca 2+ -free solution, PFOS at 100 μM failed to increase CBF (0.96-fold of vehicle control). The addition of Gd 3+ (1 μM), a store-operated Ca 2+ channel blocker, did not prevent the increase in CBF (1.09-fold (P + concentration (50 mM), which causes depolarization of the plasma membrane potential and a transient increase in [Ca 2+ ] i , increased CBF by 20% (P 2+ channels (VDCCs) in stimulation of CBF. Nifedipine (30 μM), a selective VDCC blocker, antagonized the effects of high K + (0.92-fold of high K + solution) and PFOS (0.96-fold of vehicle control) on CBF. In cells from peroxisome proliferator-activated receptor α (PPARα)-null mice, PFOS still increased CBF (1.12-fold (P 2+ through VDCC

  3. Self-shielding flex-circuit drift tube, drift tube assembly and method of making

    Science.gov (United States)

    Jones, David Alexander

    2016-04-26

    The present disclosure is directed to an ion mobility drift tube fabricated using flex-circuit technology in which every other drift electrode is on a different layer of the flex-circuit and each drift electrode partially overlaps the adjacent electrodes on the other layer. This results in a self-shielding effect where the drift electrodes themselves shield the interior of the drift tube from unwanted electro-magnetic noise. In addition, this drift tube can be manufactured with an integral flex-heater for temperature control. This design will significantly improve the noise immunity, size, weight, and power requirements of hand-held ion mobility systems such as those used for explosive detection.

  4. R+-methanandamide inhibits tracheal response to endogenously released acetylcholine via capsazepine-sensitive receptors.

    Science.gov (United States)

    Nieri, Paola; Martinotti, Enrica; Testai, Lara; Adinolfi, Barbara; Calderone, Vincenzo; Breschi, Maria Cristina

    2003-01-10

    The effects of cannabinoid drugs on the cholinergic response evoked by electrical field stimulation (0.2 ms pulse width, 20 V amplitude, 10 Hz, 7.5 s train duration) in guinea-pig tracheal preparations were investigated. The stable analogue of the endocannabinoid anandamide, R(+)-methanandamide (10(-7)-10(-4) M), produced a dose-dependent inhibition (up to 27+/-5% of control) of electrical field stimulation-mediated atropine-sensitive response. This effect was not blocked by the selective cannabinoid CB(1) receptor antagonist N-(piperidin-1-yl)-5-(4-chlorophenyl)-1-(2,4-dichlorophenyl)-4-methyl-1H-pyrazole-3 carboxamide hydrochloride (SR 141716A; 10(-6) M), and was not reproduced with the cannabinoid CB(1)/CB(2) receptor agonist R(+)-[2,3-dihydro-5-methyl-[(morpholinyl)methyl]pyrrolo [1,2,3-de]-1,4-benzoxazin-6-yl]-(1-naphthalenyl)methanone mesylate) (WIN 55,212-2; 10(-8)-10(-5) M) or the cannabinoid CB(2) receptor selective agonist 1-propyl-2-methyl-3-(1-naphthoyl)indole (JWH-015; 10(-8)-10(-5) M); it was, on the contrary, antagonized by the vanilloid antagonist 2-[2-(4-chlorophenyl)ethyl-amino-thiocarbonyl]-7,8-dihydroxy-2,3,4,5-tetrahydro-1H-2 benzazepine (capsazepine; 10(-6) M). At the postjunctional level, neither R(+)-methanandamide nor WIN 55,212-2 nor JWH-015 did affect tracheal contractions induced by exogenous acetylcholine (10(-6) M). An inhibitory vanilloid receptor-mediated effect on the cholinergic response evoked by electrical stimulation was confirmed with the vanilloid agonist capsaicin, at doses (3-6 x 10(-8) M) which poorly influenced the basal smooth muscle tone of trachea. In conclusion, our data indicate that in guinea-pig trachea (a) neither CB(1) nor CB(2) cannabinoid receptor-mediated modulation of acetylcholine release occurs; (b) vanilloid VR1-like receptors appear involved in R(+)-methanandamide inhibitory activity on the cholinergic response to electrical field stimulation.

  5. Silicone stent placement for primary tracheal amyloidosis accompanied by cartilage destruction.

    Science.gov (United States)

    Ryu, Duck Hyun; Eom, Jung Seop; Jeong, Ho Jung; Kim, Jung Hoon; Lee, Ji Eun; Jun, Ji Eun; Song, Dae Hyun; Han, Joungho; Kim, Hojoong

    2014-06-01

    Primary tracheal amyloidosis (PTA) can lead to airway obstructions, and patients with severe PTA should undergo bronchoscopic interventions in order to maintain airway patency. Focal airway involvements with amyloidosis can only be treated with mechanical dilatation. However, the PTA with diffused airway involvements and concomitant cartilage destructions requires stent placement. Limited information regarding the usefulness of silicone stents in patients with PTA has been released. Therefore, we report a case of diffused PTA with tracheomalacia causing severe cartilage destruction, which is being successfully managed with bronchoscopic interventions and silicone stent placements.

  6. Control and optimization of solute transport in a thin porous tube

    KAUST Repository

    Griffiths, I. M.

    2013-03-01

    Predicting the distribution of solutes or particles in flows within porous-walled tubes is essential to inform the design of devices that rely on cross-flow filtration, such as those used in water purification, irrigation devices, field-flow fractionation, and hollow-fibre bioreactors for tissue-engineering applications. Motivated by these applications, a radially averaged model for fluid and solute transport in a tube with thin porous walls is derived by developing the classical ideas of Taylor dispersion. The model includes solute diffusion and advection via both radial and axial flow components, and the advection, diffusion, and uptake coefficients in the averaged equation are explicitly derived. The effect of wall permeability, slip, and pressure differentials upon the dispersive solute behaviour are investigated. The model is used to explore the control of solute transport across the membrane walls via the membrane permeability, and a parametric expression for the permeability required to generate a given solute distribution is derived. The theory is applied to the specific example of a hollow-fibre membrane bioreactor, where a uniform delivery of nutrient across the membrane walls to the extra-capillary space is required to promote spatially uniform cell growth. © 2013 American Institute of Physics.

  7. Set-up for steam generator tube bundle washing after explosion expanding the tubes

    International Nuclear Information System (INIS)

    Osipov, S.I.; Kal'nin, A.Ya.; Mazanenko, M.F.

    1985-01-01

    Set-up for steam generator tube bundle washing after the explosion expanding of tubes is described. Washing is accomplished by distillate. Steam is added to distillate for heating, and compersed air for preventing hydraulic shock. The set-up is equiped by control equipment. Set-up performances are presented. Time for one steam generator washing constitutes 8-12 h. High economic efficiency is realized due to the set-up introduction

  8. TO STUDY EFFECT OF GABAPENTIN ON ATTENUATION OF PRESSOR RESPONSE TO DIRECT LARYNGOSCOPY AND TRACHEAL INTUBATION AND ON PERIOPERATIVE PAIN

    Directory of Open Access Journals (Sweden)

    Sarita Chandapet

    2017-05-01

    Full Text Available BACKGROUND Endotracheal intubation was first described by Rowbotham and Magill in 1921. 1 In 1940 Reid and Brace first described hemodynamic response to Laryngoscopy and Intubation due to Noxious stimuli. 2 The circulatory responses to laryngeal and tracheal stimulation are due to sympathoadrenal stimulation. 3 Laryngoscopy and Tracheal Intubation induces changes in circulating Catecholamine levels significantly. Norepinephrine, Epinephrine and Dopamine levels rise, but the raise in Norepinephrine levels is consistently associated with elevation of Blood pressure and Heart rate. 4 Even though the elevation in Blood pressure and Heart rate due to Laryngoscopy and Intubation are brief, they may have detrimental effects in high risk patients including Myocardial Infarction, Cardiac failure, Intracranial haemorrhage and increases in Intracranial pressure. 5 Many strategies have been advocated to minimize these hemodynamic adverse responses and aimed at different levels of the reflex arc. 6 Block of the peripheral sensory receptors and afferent input is by topical application and infiltration of Local Anaesthetic to Superior laryngeal nerve. Block of central mechanism of integration and sensory input by drugs like Fentanyl, Morphine etc. Block of efferent pathway and effector sites IV Lignocaine, Beta blockers, Calcium channel blockers, Hydralazine etc. No single drug or technique is satisfactory. The aim of this study is to evaluate the efficacy of Gabapentin in attenuating hemodynamic response to laryngoscopy and intubation in a placebo controlled double blind study. MATERIALS AND METHODS A clinical comparative study of attenuation of sympathetic response to laryngoscopy and intubation was done in 150 patients posted for elective surgery divided into two groups and were randomly allocated Group 1 – placebo capsules with sugar and Group 2 – Gabapentin 300 mg capsules. Heart rate, systolic, diastolic blood pressure, mean arterial pressure were

  9. Testing and analysis of tube voltage and tube current in the radiation generator for mammography

    International Nuclear Information System (INIS)

    Jung, Hong Ryang; Hong, Dong Hee; Han, Beom Hui

    2014-01-01

    Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant , manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration 'about the safety of diagnostic radiation generator rule' specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected

  10. A systematic review and meta-regression analysis of mivacurium for tracheal intubation.

    Science.gov (United States)

    Vanlinthout, L E H; Mesfin, S H; Hens, N; Vanacker, B F; Robertson, E N; Booij, L H D J

    2014-12-01

    We systematically reviewed factors associated with intubation conditions in randomised controlled trials of mivacurium, using random-effects meta-regression analysis. We included 29 studies of 1050 healthy participants. Four factors explained 72.9% of the variation in the probability of excellent intubation conditions: mivacurium dose, 24.4%; opioid use, 29.9%; time to intubation and age together, 18.6%. The odds ratio (95% CI) for excellent intubation was 3.14 (1.65-5.73) for doubling the mivacurium dose, 5.99 (2.14-15.18) for adding opioids to the intubation sequence, and 6.55 (6.01-7.74) for increasing the delay between mivacurium injection and airway insertion from 1 to 2 min in subjects aged 25 years and 2.17 (2.01-2.69) for subjects aged 70 years, p < 0.001 for all. We conclude that good conditions for tracheal intubation are more likely by delaying laryngoscopy after injecting a higher dose of mivacurium with an opioid, particularly in older people. © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  11. Tracheal relaxation of five medicinal plants used in Mexico for the treatment of several diseases.

    Science.gov (United States)

    Sánchez-Recillas, Amanda; Mantecón-Reyes, Paul; Castillo-España, Patricia; Villalobos-Molina, Rafael; Ibarra-Barajas, Maximiliano; Estrada-Soto, Samuel

    2014-03-01

    To assess the relaxant effect of several organic extracts obtained from Agastache mexicana (A. mexicana), Cochlospermum vitifolium (C. vitifolium), Cordia morelosana (C. morelosana), Lepechinia caulescens (L. caulescens) and Talauma mexicana (T. mexicana) used in Mexican traditional medicine for the treatment of several diseases. Extracts were obtained by maceration at room temperature using hexane, dichloromethane and methanol for each plant material. The organic extracts were evaluated ex vivo to determine their relaxant activity on the contractions induced by carbachol (cholinergic receptor agonist, 1 μ mol/L) in isolated rat tracheal rings. A total of 15 extracts were evaluated (three for each species). All test samples showed significant relaxant effect, in a concentration-dependent manner, on the contractions induced by 1 μ mol/L carbachol, with exception of extracts from C. morelosana. Active extracts were less potent than theophylline [phosphodiesterase inhibitor, EC50: (28.79±0.82) μg/mL] that was used as positive control. Concentration-response curves revealed that the extracts with more significant effects were dichloromethanic extracts of T. mexicana [Emax: (103.03±3.32)% and EC50: (159.39±3.72) μg/mL) and C. vitifolium [Emax: (106.58±2.42)% and EC50: (219.54±7.61) μg/mL]. Finally, hexanic and dichloromethanic extracts from A. mexicana were fully effective but less potent than T. mexicana and C. vitifolium. Less polar extracts obtained from A. mexicana, T. mexicana and C. vitifolium exhibited greater relaxant effect on tracheal rat rings, which allows us to suggest them as sources for the isolation of bioactive molecules with potential therapeutic value in the treatment of asthma. Copyright © 2014 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  12. Remote-controlled television for locating leaking tubes in pressurized-water reactor steam generators

    International Nuclear Information System (INIS)

    Cormault, P.; Denis, J.

    1978-01-01

    The Scarabee system is designed for observation of the tubes in water boxes of pressurized-water reactor nuclear-power-station steam generators. It consists essentially of a camera and a projector used as a marker, both of which swivel freely. The whole unit is housed in a water-tight container which can easily be decontaminated. Remote control of camera and marker movement is carried out from a console. (author)

  13. The diagnostic value of multi-slice spiral CT virtual bronchoscopy in tracheal and bronchial disease

    International Nuclear Information System (INIS)

    Han Ying; Ma Daqing

    2006-01-01

    Objective: To assess the diagnostic value of multi-slice spiral CT virtual bronchoscopy (CTVB) in tracheal and bronchial disease. Methods: Forty-two patients including central lung cancer (n=35), endobronchial tuberculosis (n=3), intrabronchial benign tumor (n=3), and intrabronchial foreign body (n=1) were examined by using multi-slice spiral CT examinations. All the final diagnosis were proved by pathology except 1 patient with endoluminal foreign body was proved by clinic. All patients were scanned on GE Lightspeed 99 scanner, using 10 mm collimation, pitch of 1.35, and reconstructed at 1 mm intervals and 1.25 mm thickness. The chest images of transverse CT and virtual bronchoscopy were viewed by two separate radiologists who were familiar with the tracheal and bronchial anatomy. Results: Among the 42 patients, the tumor of trachea and bronchial lumen appeared as masses in 22 of 35 patients with central lung cancer and bronchial stenosis was found in 13 of 35 patients with central lung cancer, and bronchial wall thickening was revealed on transverse CT in all 35 cases. 3 patients of endobronchial tuberculosis showed bronchial lumen narrowing on CTVB, the bronchial wall thickening was revealed on transverse CT, and the length of the wall thickening was long. 3 patients with intrabronchial benign tumor showed nodules in trachea and bronchial lumen on CTVB, and without wall thickening on transverse CT. CTVB could detect the occlusion of bronchial lumen in 1 patient with intrabronchial foreign body and CTVB was able to visualize the areas beyond stenosis, and the bronchial wall was without thickening on transverse CT. Conclusion: Multi- slice spiral CTVB could reflect the morphology of tracheal and bronchial disease. Combined with transverse CT, it could provide diagnostic reference value for bronchial disease. (authors)

  14. Management of postintubation tracheal stenosis: appropriate indications make outcome differences.

    Science.gov (United States)

    Melkane, Antoine E; Matar, Nayla E; Haddad, Amine C; Nassar, Michel N; Almoutran, Homère G; Rohayem, Ziad; Daher, Mohammad; Chalouhy, Georges; Dabar, George

    2010-01-01

    Laryngotracheal stenosis is difficult to treat and its etiologies are multiple; nowadays, the most common ones are postintubation or posttracheostomy stenoses. To provide an algorithm for the management of postintubation laryngotracheal stenoses (PILTS) based on the experience of a tertiary care referral center. A retrospective study was conducted on all patients treated for PILTS over a 10-year period. Patients were divided into a surgically and an endoscopically treated group according to predefined criteria. The characteristics of the two groups were analyzed and the outcomes compared. Thirty-three consecutive patients were included in the study: 14 in the surgically treated group and 19 in the endoscopically treated group. Our candidates for airway surgery were healthy patients presenting with complex tracheal stenoses, subglottic involvement or associated tracheomalacia. The endoscopic candidates were chronically ill patients presenting with simple, strictly tracheal stenoses not exceeding 4 cm in length. Stents were placed if the stenosis was associated with tracheomalacia or exceeded 2 cm in total length. In the surgically treated group, 2/14 patients needed more than one procedure versus 8/19 patients in the endoscopically treated group. At the end of the intervention, 50% of the patients were decannulated in the surgically treated group versus 84.2% in the endoscopically treated group (p = 0.03). However, the decannulation rates at 6 months and the symptomatology at rest and on exertion on the last follow-up visit were comparable in the two groups. Our experience in the management of PILTS demonstrates that both surgery and endoscopy yield excellent functional outcomes if the treatment strategy is based on clear, predefined objective criteria. Copyright 2010 S. Karger AG, Basel.

  15. Pirenzepine block of ACh-induced mucus secretion in tracheal submucosal gland cells

    International Nuclear Information System (INIS)

    Farley, J.M.; Dwyer, T.M.

    1991-01-01

    Muscarinic stimulation of mucus secretion, as measured by the release of [ 3 H]glycoprotein, was studied in explants from the tracheal epithelium of weanling swine. The mucus glycoprotein secretion was transient, ceasing within the first 10 min of a continuous exposure to 100 μM ACh. Increasing the solutions' osmotic pressure did not alter basal mucus glycoprotein secretion. Mucus glycoprotein secretion was inhibited by 2-10 μM PZP, indicting that the M 3 muscarinic receptors mediate cholinergic stimulation of mucus production

  16. [Argon plasma coagulation combined with cryotherapy via bronchoscopy for the treatment of one child with severe post-intubation tracheal stenosis and literature review].

    Science.gov (United States)

    Zhou, Kuo; Liang, Jun; Cui, Ai-hua; Fu, Ai-xia; Yang, Qiao-zhi

    2013-10-01

    To observe the short term effect of argon plasma coagulation (APC) combined with cryotherapy via bronchoscopy for treatment of severe post-intubation tracheal stenosis in a child. A 3-year old boy was admitted for cephalothorax abdominal compound trauma and dyspnea, who had severe post-incubation tracheal stenosis. The agreement about the operation risk was signed by the parents. Endotracheal APC procedure was performed with a bronchoscope under general anesthesia. The APC probe was put into the working channel of the bronchoscope. The stenotic lesion was endoscopically visualized and then coagulated by argon plasma. Such coagulation was carried out several times at the stenotic site until it gradually became dilated. The devitalized tissue was mechanically removed with grasping forceps. Thereafter, bronchoscopic cryosurgery was repeatedly performed at the stenotic site. Clinical symptoms, signs and bronchoscopic manifestations were observed right after operation, after 1 day, 10 days, 1 month and 6 months separately. Tracheal tissue hyperplasia and cyanosis disappeared, laryngeal stridor and dyspnea improved obviously right after the operation. General condition of the patient was well, there was no laryngeal stridor and dyspnea 10 days after operation. The mucosa of the surgical site was smooth and no tracheostenosis was seen under bronchoscope at 1 month and 6 months after the operation. Argon plasma coagulation combined with cryotherapy via bronchoscope is an effective method to treat tracheal stenosis of children, which needs further exploration for the application.

  17. Influenza A infection attenuates relaxation responses of mouse tracheal smooth muscle evoked by acrolein.

    Science.gov (United States)

    Cheah, Esther Y; Mann, Tracy S; Burcham, Philip C; Henry, Peter J

    2015-02-15

    The airway epithelium is an important source of relaxant mediators, and damage to the epithelium caused by respiratory tract viruses may contribute to airway hyperreactivity. The aim of this study was to determine whether influenza A-induced epithelial damage would modulate relaxation responses evoked by acrolein, a toxic and prevalent component of smoke. Male BALB/c mice were inoculated intranasally with influenza A/PR-8/34 (VIRUS-infected) or allantoic fluid (SHAM-infected). On day 4 post-inoculation, isometric tension recording studies were conducted on carbachol pre-contracted tracheal segments isolated from VIRUS and SHAM mice. Relaxant responses to acrolein (30 μM) were markedly smaller in VIRUS segments compared to SHAM segments (2 ± 1% relaxation vs. 28 ± 5%, n=14, pacrolein and SP were reduced in VIRUS segments (>35% reduction, n=6, pacrolein were profoundly diminished in tracheal segments isolated from influenza A-infected mice. The mechanism through which influenza A infection attenuates this response appears to involve reduced production of PGE2 in response to SP due to epithelial cell loss, and may provide insight into the airway hyperreactivity observed with influenza A infection. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Tracheal intubation in the ICU: Life saving or life threatening?

    Directory of Open Access Journals (Sweden)

    Jigeeshu V Divatia

    2011-01-01

    Full Text Available Tracheal intubation (TI is a routine procedure in the intensive care unit (ICU, and is often life saving. However, life-threatening complications occur in a significant proportion of procedures, making TI perhaps one the most common but underappreciated airway emergencies in the ICU. In contrast to the controlled conditions in the operating room (OR, the unstable physiologic state of critically ill patients along with underevaluation of the airways and suboptimal response to pre-oxygenation are the major factors for the high incidence of life-threatening complications like severe hypoxaemia and cardiovascular collapse in the ICU. Studies have shown that strategies planned for TI in the OR can be adapted and extrapolated for use in the ICU. Non-invasive positive-pressure ventilation for pre-oxygenation provides adequate oxygen stores during TI for patients with precarious respiratory pathology. The intubation procedure should include not only airway management but also haemodynamic, gas exchange and neurologic care, which are often crucial in critically ill patients. Hence, there is a necessity for the implementation of an Intubation Bundle during routine airway management in the ICU. Adherence to a plan for difficult airway management incorporating the use of intubation aids and airway rescue devices and strategies is useful.

  19. A new and simple method of fabrication of tracheostomal prosthesis

    Directory of Open Access Journals (Sweden)

    N Vidya Sankari

    2015-01-01

    Full Text Available Patients with a tracheostomy stoma experience compromised speech and function due to the associated changes in airflow patterns. Rehabilitation of a patient with tracheal stoma is a highly challenging task. The main objective is to design an inexpensive, easily fabricated stomal prosthesis for postlaryngectomy patients who require prolonged tracheotomy. This clinical case report describes a 29-year-old male patient who underwent for tracheotomy 3 months before for respiratory distress following a suicidal attempt. Hence tracheotomy was done, and the patient has been with the tracheostomal tube since surgery for the past 3 months. Laryngoscopy examination reported as restricted bilateral vocal cord movements, and the cords were in the adducted position with minimal glottic chink. No history of difficulty in swallowing. On examination, no scar or ulceration is seen around the stoma. The skin around the stoma is healthy. The patient was referred to the oral and maxillofacial Prosthodontics Department from the Department of ENT. The patient′s old tracheostomal tube was used as the dimensions of the custom made tracheal prosthesis without making a functional impression of the mature stoma. A tracheal button was made with 2 mm polyethylene urethane sheet to maintain the airway patency of the mature stoma. Width and length of the old tracheostomal tube were measured and customized with polyurethane sheet by directly flaming over heat. The finished product was thin, flexible, maintains enhanced tear strength, require no tapes or adhesives and less technique sensitive. These properties of the prosthesis make more advantageous than the commercially available tracheal buttons. The result in this patient was excellent with no postoperative complications. An innovative approach for fabrication of tracheostomal prosthesis was discussed to increase its successful use in tracheostomal patients. The patient′s old tracheostomal tube was used as the dimensions

  20. Improved guide tube bulge tool

    International Nuclear Information System (INIS)

    Vaill, R.E.; Phillips, W.D.

    1979-01-01

    A guide tube bulge tool for securing control rod guide tubes to a fuel assembly grid, includes a cylinder having several flexible tines each of which is equipped with a semispherical radially outwardly extending projection. A tapered ram fits into the cylinder so as to force the tines outwardly when the ram is pulled into the cylinder while supporting the other tines. (UK)

  1. TRACHEAL AND BRONCHIAL ABNORMALITIES IN PATIENTS WITH SIGNIFICANT OBSTRUCTIVE SYNDROME: ACCORDING TO BRONCHOSCOPIC

    OpenAIRE

    M. L. Shteiner

    2014-01-01

    The endobronchial pattern of significant bronchial obstructive syndrome of various etiologies was analyzed in 4,000 patients with this condition. At the same time, bronchial malformations were encountered as supplementary bronchi of the left and right basal pyramids, axillary left bronchi, supplementary and displaced tracheal bronchi, and a single case of distal transposition of the right proximal bronchus in 1.58% of cases. According to the bronchoscopic findings, supplementary bronchi and t...

  2. Replication of avian influenza viruses in equine tracheal epithelium but not in horses

    OpenAIRE

    Chambers, Thomas M.; Balasuriya, Udeni B. R.; Reedy, Stephanie E.; Tiwari, Ashish

    2013-01-01

    We evaluated a hypothesis that horses are susceptible to avian influenza viruses by in vitro testing, using explanted equine tracheal epithelial cultures, and in vivo testing by aerosol inoculation of ponies. Results showed that several subtypes of avian influenza viruses detectably replicated in vitro. Three viruses with high in vitro replication competence were administered to ponies. None of the three demonstrably replicated or caused disease signs in ponies. While these results do not exh...

  3. The Quality Assurance_Quality Control of the Monitored Drift Tubes at the HEP Laboratory of the National Technical University of Athens

    CERN Document Server

    Alexopoulos, T; Dris, M; Filippas, A V; Fokitis, E; Gazis, E N; Katsoufis, E C; Maltezos, A; Maltezos, S; Papadopoulos, E; Papadopoulou, T D; Savva, Panagiota S; Stavropoulos, G D; Tsipolitis, G; Tzamariudaki, E

    2001-01-01

    The description of the Quality Assurance and Quality Control (QA_QC) procedures for the Monitored Drift Tubes (MDT's) followed at the HEP Laboratory of NTUA are presented and results of the tested tubes are given. The MDT's are the elements from which muon chambers for the ATLAS/LHC Muon Spectrometer are built..

  4. Diagnosis of tracheomalacia using tracheal dynamic respiratory-scan

    International Nuclear Information System (INIS)

    Matsui, Teruo; Watabe, Hideki; Ikeda, Sadao

    1995-01-01

    We performed tracheal-dynamic respiratory scan (T-DRS) in 54 cases which were thought to be tracheomalacia clinically. T-DRS was performed by TOSHIBA TCT-900S at the level of the aortic arch under the condition of 120 kV (140 kV), 100 mA, 5 mm of slice width for 20 seconds when the patient was directed to breath rapidly or slowly. In 19 cases, which underwent both T-DRS and bronchoscopy, could evaluate the results. Only one case was overestimated by T-DRS than bronchoscopic findings, while 9 cases were underestimated and 9 cases were equal. Though T-DRS tended to underestimate the degree of the stenosis of tracheomalacia than bronchoscopic finding. T-DRS can do more objective evaluation than bronchoscopy non-invasively and thought to be useful for the evaluation of tracheomalalcia. (author)

  5. Fabrication characteristics of zircaloy tubes for nuclear reactors

    International Nuclear Information System (INIS)

    Haydt, H.M.

    1980-11-01

    The production sequence for zircaloy cladding tubes to be used in nuclear reactors is described, with emphasis on the texture after reduction and on the variation in the hydrides orientation. The qualities requested for the cladding tubes are presented and reference is made to the quality control applied in the process. The destructive tests as well as the final inspection to which those tubes are subjected are related. A Fabrication Quality Project is requested from the manufacturers by reason of what Quality Control Plans are submitted to be clients. At last an evaluation of the quality to be obtained and of the control performed is mentioned. (Author) [pt

  6. All India Difficult Airway Association 2016 guidelines for the management of unanticipated difficult tracheal intubation in obstetrics

    Directory of Open Access Journals (Sweden)

    Venkateswaran Ramkumar

    2016-01-01

    Full Text Available The various physiological changes in pregnancy make the parturient vulnerable for early and rapid desaturation. Severe hypoxaemia during intubation can potentially compromise two lives (mother and foetus. Thus tracheal intubation in the pregnant patient poses unique challenges, and necessitates meticulous planning, ready availability of equipment and expertise to ensure maternal and foetal safety. The All India Difficult Airway Association (AIDAA proposes a stepwise plan for the safe management of the airway in obstetric patients. These guidelines have been developed based on available evidence; wherever robust evidence was lacking, recommendations were arrived at by consensus opinion of airway experts, incorporating the responses to a questionnaire sent to members of the AIDAA and the Indian Society of Anaesthesiologists (ISA. Modified rapid sequence induction using gentle intermittent positive pressure ventilation with pressure limited to ≤20 cm H 2 O is acceptable. Partial or complete release of cricoid pressure is recommended when face mask ventilation, placement of supraglottic airway device (SAD or tracheal intubation prove difficult. One should call for early expert assistance. Maternal SpO 2 should be maintained ≥95%. Apnoeic oxygenation with nasal insufflation of 15 L/min oxygen during apnoea should be performed in all patients. If tracheal intubation fails, a second- generation SAD should be inserted. The decision to continue anaesthesia and surgery via the SAD, or perform fibreoptic-guided intubation via the SAD or wake up the patient depends on the urgency of surgery, foeto-maternal status and availability of resources and expertise. Emergency cricothyroidotomy must be performed if complete ventilation failure occurs.

  7. Temperature control of thermal-gas-dynamical installation in cleaning oil-well tubes

    Science.gov (United States)

    Penner, V. A.; Martemyanov, D. B.; Pshenichnikova, V. V.

    2017-08-01

    The article provides the study results of cleaning oil-well tubes, the oil-well tube failure reasons for service by their types have been considered. The chemical method of cleaning oil-well tubes as the least expensive has been reviewed when acid solution moves to the interptube space mixing up with oil and liquidates paraffin and pitches deposits on the internal pipe surface. Except the chemical method of pipes cleaning the mechanical one was considered as well. Also the disadvantages -such as the low productivity of cleaning and design complexity- of this deposits removal method on the internal oil-well tube surface have been considered. An effective method for cleaning oil-well tubing from paraffin and pitches by the thermodynamic plant based on the aircraft engine has been introduced for the first time. The temperature distribution graph in the gas stream at the engine output has been given.

  8. On-line electrochemically controlled in-tube solid phase microextraction of inorganic selenium followed by hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Asiabi, Hamid [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Yamini, Yadollah, E-mail: yyamini@modares.ac.ir [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Seidi, Shahram [Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of); Shamsayei, Maryam; Safari, Meysam; Rezaei, Fatemeh [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of)

    2016-05-30

    In this work, for the first time, a rapid, simple and sensitive microextraction procedure is demonstrated for the matrix separation, preconcentration and determination of inorganic selenium species in water samples using an electrochemically controlled in-tube solid phase microextraction (EC-in-tube SPME) followed by hydride generation atomic absorption spectrometry (HG-AAS). In this approach, in which EC-in-tube SPME and HG-AAS system were combined, the total analysis time, was decreased and the accuracy, repeatability and sensitivity were increased. In addition, to increases extraction efficiency, a novel nanostructured composite coating consisting of polypyrrole (PPy) doped with ethyleneglycol dimethacrylate (EGDMA) was prepared on the inner surface of a stainless-steel tube by a facile electrodeposition method. To evaluate the offered setup and the new PPy-EGDMA coating, it was used to extract inorganic selenium species in water samples. Extraction of inorganic selenium species was carried out by applying a positive potential through the inner surface of coated in-tube under flow conditions. Under the optimized conditions, selenium was detected in amounts as small as 4.0 parts per trillion. The method showed good linearity in the range of 0.012–200 ng mL{sup −1}, with coefficients of determination better than 0.9996. The intra- and inter-assay precisions (RSD%, n = 5) were in the range of 2.0–2.5% and 2.7–3.2%, respectively. The validated method was successfully applied for the analysis of inorganic selenium species in some water samples and satisfactory results were obtained. - Graphical abstract: An electrochemically controlled in-tube solid phase microextraction followed by hydride generation atomic absorption spectrometry was developed for extraction and determination ultra-trace amounts of Se in aqueous solutions. - Highlights: • A nanostructured composite coating consisting of PPy doped with EGDMA was prepared. • The coating was

  9. Effect of retinol and cigarette-smoke and condensate on dye-coupled intercellular communication between hamster tracheal epithelial cells

    NARCIS (Netherlands)

    Rutten, A.A.J.J.L.; Jongen, W.M.F.; Haan, L.H.J.de; Hendriksen, E.G.J.; Koeman, J.H.

    1988-01-01

    The dye-coupled intercellular communication across gap junctions in primary hamster tracheal epithelial cells has been studied in serum-free, hormone-supplemented medium. In the absence of vitamin A, non-cytotoxic concentrations of cigarette-smoke condensate (CSC) inhibited intercellular

  10. Comparison of the effects of oxycodone versus fentanyl on airway reflex to tracheal extubation and postoperative pain during anesthesia recovery after laparoscopic cholecystectomy: A double-blind, randomized clinical consort study.

    Science.gov (United States)

    Choi, Eun Kyung; Kwon, Nyeongkeon; Park, Sang-Jin

    2018-03-01

    Fentanyl has been suggested to be effective for controlling airway and hemodynamic responses to tracheal extubation. This study was performed to compare the effects of oxycodone and fentanyl on airway and hemodynamic responses and postoperative pain during the recovery period in patients undergoing laparoscopic cholecystectomy. Ninety patients aged 18 to 65 years were randomly allocated to 1 of 3 groups: fentanyl, oxycodone, and control. Coughing responses (incidence and severity), hemodynamic responses during the recovery period, and acute postoperative pain were assessed. The incidence of cough was decreased in the fentanyl and oxycodone groups compared with that in the control group at the points of awareness and extubation, and no significant difference was observed between the 2 treatment groups. Severe cough response was decreased in the fentanyl and oxycodone groups compared with that in the control group at the point of extubation, and no significant change was observed in cough severity between the 2 treatment groups. Postoperative pain scores were lower in the fentanyl and oxycodone groups than those in the control group at 5 and 30 minutes postoperatively, and no significant difference was observed between the 2 treatment groups. Hemodynamic responses did not differ among the 3 groups during the recovery period. Oxycodone treatment before tracheal extubation reduced cough response and was as effective as fentanyl treatment for improving extubation quality. Furthermore, single boluses of fentanyl and oxycodone showed equal effectiveness in attenuating acute postoperative pain in patients undergoing laparoscopic cholecystectomy.

  11. Oncogene-induced progression of preneoplastic rat tracheal epithelial cells to neoplasia

    International Nuclear Information System (INIS)

    Thomassen, D.G.; Kelly, G.

    1988-01-01

    N-methyl-N'-nitro-N-nitrosoguanidine (MNNG) induced preneoplastic variants of rat tracheal epithelial (RTE) cells can be neo plastically transformed following transfection with oncogenic DNA. Variants differ with respect to the oncogenes required for neoplastic conversion. Polyma virus DNA transformed each of four variants neo plastically, whereas viral ras DNA only transformed two of four variants. These data demonstrate that preneoplastic variants of RTE cells differ with respect to the changes needed for conversion to neoplastic cells and that the variants tested are either at different stages or on different pathways of progression to neoplasia. (author)

  12. The results of surgical treatment of proximal long segment tracheal stenosis using bilateral hyoid bone cutting with suprahyoid release

    Directory of Open Access Journals (Sweden)

    khadivi E

    2009-10-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Post-intubation tracheal stenosis is a serious problem and surgical resection is the method of choice in long segment tracheal stenosis treatment. The aim of this study was to review the results of surgical treatment of long segment post intubation tracheal stenosis and the role of bilateral hyoid bone cutting in supra- hyoid release technique."n"nMethods: Between 2004 to 2008, 14 patients with proximal long segment tracheal stenosis with resection of more than 40% of trachea length were evaluated regarding surgical technique and post-operative results."n"nResults: The mean age of patients was 22.2±0.4 years. Etiology in all patients were head trauma and prolonged intubation and all patients had tracheostomy at the time of trearment. Average time between surgery and first admission was 4.5±0.5 months. Average length of stenosis and resected segment were 3.6±0.5 and 4.3±0.5cm respectively. Average increased length of trachea after bilateral hyoid bone cutting was 1.1±0.3cm. Postoperative complications occurred in one patient with wound infection, and 4 patients had stenosis recurrence which was treated in 3 patients using multiple dilation. Quality of life 2 years after surgery in 71% of patients were

  13. In service inspection for steam generator tubes

    International Nuclear Information System (INIS)

    Comby, R.; Eyrolles, Ph.

    1988-01-01

    In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations [fr

  14. A portable tube exciting X-ray fluorescence analysis system

    International Nuclear Information System (INIS)

    Yang Qiang; Lai Wanchang; Ge Liangquan

    2009-01-01

    Article introduced a portable tube exciting X-ray fluorescence analysis system which is based on arm architecture. Also, we designed Tube control circuit and finished preliminary application. The energy and the intensity of the photon can be adjusted continuously by using the tube. Experiments show that high excitation efficiency obtained by setting the appropriate parameters of the tube for the various elements. (authors)

  15. Tracheal intubation with a flexible fibreoptic scope or the McGrath videolaryngoscope in simulated difficult airway scenarios

    DEFF Research Database (Denmark)

    Jepsen, Cecilie H; Gätke, Mona R; Thøgersen, Bente

    2014-01-01

    Grath videolaryngoscope and FFE. The participants then performed tracheal intubation on a SimMan manikin once with the McGrath videolaryngoscope and once with the FFE in three difficult airway scenarios: (1) pharyngeal obstruction; (2) pharyngeal obstruction and cervical rigidity; (3) tongue oedema. MAIN OUTCOME MEASURES...

  16. Electron emission regulator for an x-ray tube filament

    International Nuclear Information System (INIS)

    Daniels, H.E.; Randall, H.G.

    1982-01-01

    An x-ray tube ma regulator has an scr phase shift voltage regulator supplying the primary winding of a transformer whose secondary is coupled to the x-ray tube filament. Prior to initiation of an x-ray exposure, the filament is preheated to a temperature corresponding substantially to the electron emissivity needed for obtaining the desired tube ma during an exposure. During the preexposure interval, the phase shift regulator is controlled by a signal corresponding to the sum of signals representative of the voltage applied to the filament transformer, the desired filament voltage and the space charge compensation needed for the selected x-ray tube anode to cathode voltage. When an exposure is initiated, control of the voltage regulator is switched to a circuit that responds to the tube current by controlling the amount of phase shift and, hence, the voltage supplied to the transformer. Transformer leakage current compensation is provided during the exposure interval with a circuit that includes an element whose impedance is varied in accordance with the anode-to-cathode voltage setting so the element drains off tube current as required to cancel the effect of leakage current variations

  17. Awake fiberoptic or awake video laryngoscopic tracheal intubation in patients with anticipated difficult airway management

    DEFF Research Database (Denmark)

    Rosenstock, Charlotte Vallentin; Thøgersen, Bente; Afshari, Arash

    2012-01-01

    Awake flexible fiberoptic intubation (FFI) is the gold standard for management of anticipated difficult tracheal intubation. The purpose of this study was to compare awake FFI to awake McGrath® video laryngoscope, (MVL), (Aircraft Medical, Edinburgh, Scotland, United Kingdom) intubation in patients...... with an anticipated difficult intubation. The authors examined the hypothesis that MVL intubation would be faster than FFI....

  18. The use of the laryngeal tube disposable (LT-D) by paramedics during out-of-hospital resuscitation-an observational study concerning ERC guidelines 2005.

    Science.gov (United States)

    Wiese, C H R; Semmel, T; Müller, J U; Bahr, J; Ocker, H; Graf, B M

    2009-02-01

    In the current guidelines of the European Resuscitation Council (ERC), tracheal intubation, as an instrument for securing the airway during resuscitation, has become less important for persons not trained in this method. For those persons, different supraglottic airway devices are recommended by the ERC. The present investigation deals with the application of the laryngeal tube disposable (LT-D) during pre-hospital resuscitation by paramedics. During a period of 2 years (2006-2008), we registered all cardiac arrest situations in which the LT-D had been applied according to the ERC guidelines 2005. Therefore, we investigated one emergency medical system in Germany. During the defined period, 92 resuscitation attempts, recorded on standardised data sheets, were included. The LT-D was used in 46% of all cardiac arrest situations. Overall, the LT-D was successfully inserted in more than 90% of all cases on first attempt. In 95% of all cases, no problems concerning ventilation of the patient were described. As an alternative airway device recommended by the ERC in 2005, the LT-D may enable airway control rapidly and effectively. Additionally, by using the LT-D, a reduced "no-flow-time" and a better outcome may be possible.

  19. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial.

    Science.gov (United States)

    Mirmohammad-Sadeghi, Mohsen; Pourazari, Pejman; Akbari, Mojtaba

    2017-01-01

    Chest tubes are used in every case of coronary artery bypass grafting (CABG) to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group ( P = 0.001), but the trend of pain score between groups was not significantly different ( P = 0.097). The frequency of tamponade and atrial fibrillation (AF) were significantly lower in Jackson-Pratt drain group ( P drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  20. 21 CFR 868.5800 - Tracheostomy tube and tube cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheostomy tube and tube cuff. 868.5800 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5800 Tracheostomy tube and tube cuff. (a) Identification. A tracheostomy tube and tube cuff is a device intended to be placed into a...

  1. A Novel Device for Accurate Chest Tube Insertion

    DEFF Research Database (Denmark)

    Katballe, Niels; Moeller, Lars B; Olesen, Winnie H

    2016-01-01

    BACKGROUND: Optimal positioning of a large-bore chest tube is in the part of the pleural cavity that needs drainage. It is recommended that the chest tube be positioned apically in pneumothorax and basally for fluids. However, targeted chest tube positioning to a specific part of the pleural cavity...... can be a challenge. METHODS: A new medical device, the KatGuide, was developed for accurate guiding of a chest tube (28F) to an intended part of the pleural cavity. The primary end point of this randomized, controlled trial was optimal position of the chest tube. The optimal position in pneumothorax...

  2. Hydrogen isotope exchange in a metal hydride tube

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, David B. [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2014-09-01

    This report describes a model of the displacement of one hydrogen isotope within a metal hydride tube by a different isotope in the gas phase that is blown through the tube. The model incorporates only the most basic parameters to make a clear connection to the theory of open-tube gas chromatography, and to provide a simple description of how the behavior of the system scales with controllable parameters such as gas velocity and tube radius. A single tube can be seen as a building block for more complex architectures that provide higher molar flow rates or other advanced design goals.

  3. Tube plug

    International Nuclear Information System (INIS)

    Zafred, P. R.

    1985-01-01

    The tube plug comprises a one piece mechanical plug having one open end and one closed end which is capable of being inserted in a heat exchange tube and internally expanded into contact with the inside surface of the heat exchange tube for preventing flow of a coolant through the heat exchange tube. The tube plug also comprises a groove extending around the outside circumference thereof which has an elastomeric material disposed in the groove for enhancing the seal between the tube plug and the tube

  4. Ultrasonic inspection of tube to tube plate welds

    International Nuclear Information System (INIS)

    Telford, D.W.; Peat, T.S.

    1985-01-01

    To monitor the deterioration of a weld between a tube and tube plate which has been repaired by a repair sleeve inside the tube and brazed at one end to the tube, ultrasound from a crystal at the end of a rod is launched, in the form of Lamb-type waves, into the tube through the braze and allowed to travel along the tube to the weld and be reflected back along the tube. The technique may also be used for the type of heat exchanger in which, during construction, the tubes are welded to the tube plate via external sleeves in which case the ultrasound is used in a similar manner to inspect the sleeve/tube plate weld. an electromagnetic transducer may be used to generate the ultrasound. The ultrasonic head comprising the crystal and an acoustic baffle is mounted on a Perspex (RTM) rod which may be rotated by a stepping motor. Echo signals from the region of deterioration may be isolated by use of a time gate in the receiver. The device primarily detects circumferentially orientated cracks, and may be used in heat exchangers in nuclear power plants. (author)

  5. Variable-energy drift-tube linear accelerator

    Science.gov (United States)

    Swenson, Donald A.; Boyd, Jr., Thomas J.; Potter, James M.; Stovall, James E.

    1984-01-01

    A linear accelerator system includes a plurality of post-coupled drift-tubes wherein each post coupler is bistably positionable to either of two positions which result in different field distributions. With binary control over a plurality of post couplers, a significant accumlative effect in the resulting field distribution is achieved yielding a variable-energy drift-tube linear accelerator.

  6. Tracheomegaly: a complication of fetal endoscopic tracheal occlusion in the treatment of congenital diaphragmatic hernia

    Energy Technology Data Exchange (ETDEWEB)

    McHugh, Kieran; Afaq, Asim; Roebuck, Derek J. [Great Ormond Street Hospital for Children, Radiology Department, London (United Kingdom); Broderick, Nigel [Nottingham University Hospitals, Radiology Department, Nottingham (United Kingdom); Gabra, Hany O.; Elliott, Martin J. [Great Ormond Street Hospital for Children, Department of Cardiothoracic Surgery, London (United Kingdom)

    2010-05-15

    Fetal endoscopic tracheal occlusion (FETO) is a promising treatment for severe congenital diaphragmatic hernia, a condition that carries significant morbidity and mortality. It is hypothesised that balloon occlusion of the fetal trachea leads to an improvement in lung growth and development. The major documented complications of FETO to date are related to preterm delivery. To report a series of five infants who developed tracheomegaly following FETO. Review of all children referred with tracheomegaly to the paediatric intensive care and tracheal service at two referral centres. Five neonates presented with features of respiratory distress shortly after birth and were subsequently found to have marked tracheomegaly. Two neonates had tracheomalacia in addition. There are no previous reports in the literature describing tracheomalacia, or more specifically, tracheomegaly, as a consequence of FETO. We propose that the particularly compliant fetal airway is at risk of mechanical damage from in utero balloon occlusion. This observation of a new problem in this cohort suggests a thorough evaluation of the trachea should be performed in children who have had FETO in utero. It may be that balloon occlusion of the trachea earlier in utero (before 26 weeks' gestation) predisposes to this condition. (orig.)

  7. Pseudomonas aeruginosa lipopolysaccharide induces CF-like alteration of protein secretion by human tracheal gland cells.

    Science.gov (United States)

    Kammouni, W; Figarella, C; Baeza, N; Marchand, S; Merten, M D

    1997-12-18

    Human tracheal gland (HTG) serous cells are now believed to play a major role in the physiopathology of cystic fibrosis. Because of the persistent inflammation and the specific infection by Pseudomonas aeruginosa in the lung, we looked for the action of the lipopolysaccharide (LPS) of this bacteria on human tracheal gland cells in culture by studying the secretion of the secretory leukocyte proteinase inhibitor (SLPI) which is a specific serous secretory marker of these cells. Treatment with Pseudomonas aeruginosa LPS resulted in a significant dose-dependent increase in the basal production of SLPI (+ 250 +/- 25%) whilst the SLPI transcript mRNA levels remained unchanged. This LPS-induced increase in secretion was inhibited by glucocorticoides. Furthermore, LPS treatment of HTG cells induces a loss of responsiveness to carbachol and isoproterenol but not to adenosine triphosphate. These findings indicate that HTG cells treated by Pseudomonas aeruginosa LPS have the same behavior as those previously observed with CF-HTG cells. Exploration by using reverse transcriptase polymerase chain reaction amplification showed that LPS downregulated cystic fibrosis transmembrane conductance regulator (CFTR) mRNA expression in HTG cells indicative of a link between CFTR function and consequent CF-like alteration in protein secretory process.

  8. Tracheomegaly: a complication of fetal endoscopic tracheal occlusion in the treatment of congenital diaphragmatic hernia

    International Nuclear Information System (INIS)

    McHugh, Kieran; Afaq, Asim; Roebuck, Derek J.; Broderick, Nigel; Gabra, Hany O.; Elliott, Martin J.

    2010-01-01

    Fetal endoscopic tracheal occlusion (FETO) is a promising treatment for severe congenital diaphragmatic hernia, a condition that carries significant morbidity and mortality. It is hypothesised that balloon occlusion of the fetal trachea leads to an improvement in lung growth and development. The major documented complications of FETO to date are related to preterm delivery. To report a series of five infants who developed tracheomegaly following FETO. Review of all children referred with tracheomegaly to the paediatric intensive care and tracheal service at two referral centres. Five neonates presented with features of respiratory distress shortly after birth and were subsequently found to have marked tracheomegaly. Two neonates had tracheomalacia in addition. There are no previous reports in the literature describing tracheomalacia, or more specifically, tracheomegaly, as a consequence of FETO. We propose that the particularly compliant fetal airway is at risk of mechanical damage from in utero balloon occlusion. This observation of a new problem in this cohort suggests a thorough evaluation of the trachea should be performed in children who have had FETO in utero. It may be that balloon occlusion of the trachea earlier in utero (before 26 weeks' gestation) predisposes to this condition. (orig.)

  9. Tracheomegaly: a complication of fetal endoscopic tracheal occlusion in the treatment of congenital diaphragmatic hernia

    Energy Technology Data Exchange (ETDEWEB)

    McHugh, Kieran; Afaq, Asim; Roebuck, Derek J [Great Ormond Street Hospital for Children, Radiology Department, London (United Kingdom); Broderick, Nigel [Nottingham University Hospitals, Radiology Department, Nottingham (United Kingdom); Gabra, Hany O; Elliott, Martin J [Great Ormond Street Hospital for Children, Department of Cardiothoracic Surgery, London (United Kingdom)

    2010-05-15

    Fetal endoscopic tracheal occlusion (FETO) is a promising treatment for severe congenital diaphragmatic hernia, a condition that carries significant morbidity and mortality. It is hypothesised that balloon occlusion of the fetal trachea leads to an improvement in lung growth and development. The major documented complications of FETO to date are related to preterm delivery. To report a series of five infants who developed tracheomegaly following FETO. Review of all children referred with tracheomegaly to the paediatric intensive care and tracheal service at two referral centres. Five neonates presented with features of respiratory distress shortly after birth and were subsequently found to have marked tracheomegaly. Two neonates had tracheomalacia in addition. There are no previous reports in the literature describing tracheomalacia, or more specifically, tracheomegaly, as a consequence of FETO. We propose that the particularly compliant fetal airway is at risk of mechanical damage from in utero balloon occlusion. This observation of a new problem in this cohort suggests a thorough evaluation of the trachea should be performed in children who have had FETO in utero. It may be that balloon occlusion of the trachea earlier in utero (before 26 weeks' gestation) predisposes to this condition. (orig.)

  10. Control chart analysis of data regarding 0.2% yield strength (YS) and percent total circumferential elongation (%TCE) for zircaloy clad tubes for PHWR and BWR fuels

    International Nuclear Information System (INIS)

    Yadav, M.B.; Singh, Hari; Vaidyanathan, S.; Sood, D.D.; Raghavan, S.V.; Bandyopadhyay, A.K.; Kulkarni, P.G.

    1992-01-01

    Zircaloy cladding tubes for PHWR and BWR fuels are manufactured and tested at Nuclear Fuel Complex (NFC), Hyderabad. Atomic Fuels Division is carrying out the quality assurance of the fuels on behalf of Nuclear Power Corporation (NPC). In this paper an attempt has been made to assess whether the quality of the clad tubes has met the requirements specified for the two mechanical properties of the tubes namely 0.2% yield strength and percent total circumferential elongation using control chart technique. For this purpose data for about 100 lots in each case were used. Process means and process standard deviations for these properties and the control limits for the corresponding control charts were estimated. The main findings are: (i) In case of PHWR tubes the production quality level with respect to 0.2% YS is higher, while that in case of %TCE is lower causing rejection of lots. On the other hand in the case of BWR tubes the production quality levels with respect to both the properties are higher than the required one. (ii) With respect to 0.2% YS, in case of BWR tubes a change in the pattern of distribution is detected beyond the lot serial no.47. However in case of PHWR tubes, though the data falls into two groups, no such pattern is seen. A modification in the acceptance/rejection criterion of the lot has been suggested. It is also pointed out that to have a correct picture of the total variation it is necessary to study the within tube variation. (author). 4 figs, 2 tabs

  11. Un nuevo caso de pseudotumor inflamatorio de la tráquea A new case of inflammatory tracheal tumor

    Directory of Open Access Journals (Sweden)

    Edelberto Fuentes Valdés

    2008-12-01

    Full Text Available El pseudotumor inflamatorio de tráquea es poco frecuente y puede simular un tumor cuando se localiza en la luz traqueal o bronquial. El objetivo del presente artículo fue presentar un nuevo caso y revisar la literatura especializada. Se trató de una paciente de 23 años de edad, con cuadro de disnea de varios años de evolución, tratada con el diagnóstico de asma bronquial. Fue intervenida de urgencia por empeoramiento de la disnea y diagnóstico de tumor intratraqueal, según estudio broncoscópico. Se practicó la resección de 5 anillos traqueales con anastomosis término-terminal. La evolución posoperatoria fue satisfactoria y la paciente se encuentra libre de recidiva 5 años después de la operación.The inflammatory tracheal pseudotumor is rare and it may mimic a tumor when it is located in the tracheal or bronchial light. The objective of this article was to present a new case and to review the specialized literature. The case of a 23-year-old patient with a picture of dyspnea of several years of evolution treated with diagnosis of bronchial asthma was reported. She underwent emergency surgery due the worsening of dypsnea and to the diagnosis of intratracheal tumor according to a bronchoscopic study. The resection of 5 tracheal rings was performed with termino-terminal anastomosis. The postoperative evolution was satisfactory and the patient has been free of relapse five years after the operation.

  12. U-tube steam generator modelling: application to level control and comparison with plant data

    International Nuclear Information System (INIS)

    Gautier, A.; Petetrot, J.F.; Roulet, A.; Ruiz, P.; Zwingelstein, G.

    1979-01-01

    A nonlinear multinode digital model of a recirculating U-tube steam generator is first described. Comparison between the model and Fessenheim and Bugey tests results on power step and full load rejection is given. These transients are of special interest because they provide information on the boiler high frequency response and also insights into steam generator non linear behaviour. An example of steam generator modelling as applied to control system design is then presented. This example demonstrates major improvement of control loop performance at low load following implementation of a non linear gain which allows more efficient control of large perturbations. Results of testing on the Bugey 4 plant are also indicated

  13. Inhibition by TNF-alpha and IL-4 of cationic lipid mediated gene transfer in cystic fibrosis tracheal gland cells.

    Science.gov (United States)

    Bastonero, Sonia; Gargouri, Myriem; Ortiou, Sandrine; Guéant, Jean-Louis; Merten, Marc D

    2005-11-01

    In vivo, tracheal gland serous cells highly express the cystic fibrosis transmembrane conductance regulator (cftr) gene. This gene is mutated in the lethal monogenic disease cystic fibrosis (CF). Clinical trials in which the human CFTR cDNA was delivered to the respiratory epithelia of CF patients have resulted in weak and transient gene expression. As CF is characterized by mucus inspissation, airway infection, and severe inflammation, we tested the hypothesis that inflammation and especially two cytokines involved in the Th1/Th2 inflammatory response, interleukin 4 (IL-4) and TNFalpha, could inhibit gene transfer efficiency using a model of human CF tracheal gland cells (CF-KM4) and Lipofectamine reagent as a transfection reagent. The specific secretory defects of CF-KM4 cells were corrected by Lipofectamine-mediated human CFTR gene transfer. However, this was altered when cells were pre-treated with IL-4 and TNFalpha. Inhibition of luciferase reporter gene expression by IL-4 and TNFalpha pre-treated CF-KM4 cells was measured by activity and real-time RT-PCR. Both cytokines induced similar and synergistic inhibition of transgene expression and activity. This cytokine-mediated inhibition could be prevented by anti-inflammatory agents such as glucocorticoids but not by non-steroidal (NSAI) agents. This data suggests that an inflammatory context generated by IL-4 and TNFalpha can inhibit human CFTR gene transfer in CF tracheal gland cells and that glucocorticoids may have a protecting action. Copyright (c) 2005 John Wiley & Sons, Ltd.

  14. Operative behaviour of a condenser tube under ETA chemistry

    International Nuclear Information System (INIS)

    Chocron, Mauricio; Burkart, Arturo; Rodriguez, Ivanna; Raul, Manera; Diego, Quinteros

    2012-09-01

    Among the various recommendations for the surveillance of the integrity of the materials of the Secondary Cycle (Balance of Plant) it is the periodic removal of a steam generator tube and a condenser tube and their analysis. It considers assessment of the water chemistry, corrosion and the reciprocal effect on or from other components of the cycle. Embalse N.P.P. is a CANDU 6 type, Pressurized Heavy Water Reactor, located in Cordoba Province, Argentina. Previous papers have shown results on tubes removed from the steam generators (Bordoni et al., NPC'08, September 15-18, 2008, Berlin, Germany; 6 th Canadian Nuclear Society - Steam Generators Conference, November 8-11, 2009, Toronto, Canada). Considering that the Embalse BOP has mixed metallurgy, i.e., steam generator tubes made of A800, piping made of ferrous alloys and condenser tubes made of Admiralty Brass and also taking into account that the chemistry has been modified from Morpholine control to ETA control (Fernandez et. al, NPC'2010, October 3-7, Quebec City, Canada), it has been decided to remove and analyze a condenser tube that has been placed in operation coincidently with the establishment of the ETA chemical control. The extraction is dated along with the November 2011 Plant Programmed Outage. Objectives are assessing the operative behavior of the tube performing visual and optical microscope inspection, SEM analysis of the oxides and deposits in exposed surfaces and occluded locations like tube sheet and other tests as well. Results are compared to the same analysis performed on a new tube in storage and integrated with the chemical operative figures of the cycle during the period: chemical data and corrosion products transport. (authors)

  15. Predicting the need for nonstandard tracheostomy tubes in critically ill patients.

    Science.gov (United States)

    Pandian, Vinciya; Hutchinson, Christoph T; Schiavi, Adam J; Feller-Kopman, David J; Haut, Elliott R; Parsons, Nicole A; Lin, Jessica S; Gorbatkin, Chad; Angamuthu, Priya G; Miller, Christina R; Mirski, Marek A; Bhatti, Nasir I; Yarmus, Lonny B

    2017-02-01

    Few guidelines exist regarding the selection of a particular type or size of tracheostomy tube. Although nonstandard tubes can be placed over the percutaneous kit dilator, clinicians often place standard tracheostomy tubes and change to nonstandard tubes only after problems arise. This practice risks early tracheostomy tube change, possible bleeding, or loss of the airway. We sought to identify predictors of nonstandard tracheostomy tubes. In this matched case-control study at an urban, academic, tertiary care medical center, we reviewed 1220 records of patients who received a tracheostomy. Seventy-seven patients received nonstandard tracheostomy tubes (cases), and 154 received standard tracheostomy tubes (controls). Sex, endotracheal tube size, severity of illness, and computed tomography scan measurement of the distance from the trachea to the skin at the level of the superior aspect of the anterior clavicle were significant predictors of nonstandard tracheostomy tubes. Specifically, trachea-to-skin distance >4.4 cm and endotracheal tube sizes ≥8.0 were associated with nonstandard tracheostomy. The findings suggest that clinicians should consider using nonstandard tracheostomy tubes as the first choice if the patient is male with an endotracheal tube size ≥8.0 and has a trachea-to-skin distance >4.4 cm on the computed tomography scan. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Cell Wall Composition, Biosynthesis and Remodeling during Pollen Tube Growth

    Directory of Open Access Journals (Sweden)

    Jean-Claude Mollet

    2013-03-01

    Full Text Available The pollen tube is a fast tip-growing cell carrying the two sperm cells to the ovule allowing the double fertilization process and seed setting. To succeed in this process, the spatial and temporal controls of pollen tube growth within the female organ are critical. It requires a massive cell wall deposition to promote fast pollen tube elongation and a tight control of the cell wall remodeling to modify the mechanical properties. In addition, during its journey, the pollen tube interacts with the pistil, which plays key roles in pollen tube nutrition, guidance and in the rejection of the self-incompatible pollen. This review focuses on our current knowledge in the biochemistry and localization of the main cell wall polymers including pectin, hemicellulose, cellulose and callose from several pollen tube species. Moreover, based on transcriptomic data and functional genomic studies, the possible enzymes involved in the cell wall remodeling during pollen tube growth and their impact on the cell wall mechanics are also described. Finally, mutant analyses have permitted to gain insight in the function of several genes involved in the pollen tube cell wall biosynthesis and their roles in pollen tube growth are further discussed.

  17. Heat Exchanger Tube to Tube Sheet Joints Corrosion Behavior

    Directory of Open Access Journals (Sweden)

    M. Iancu

    2013-03-01

    Full Text Available Paper presents the studies made by the authors above the tube to tube sheet fittings of heat exchanger with fixed covers from hydrofining oil reforming unit. Tube fittings are critical zones for heat exchangers failures. On a device made from material tube and tube sheet at real joints dimensions were establish axial compression force and traction force at which tube is extracted from expanded joint. Were used two shapes joints with two types of fittings surfaces, one with smooth hole of tube sheet and other in which on boring surface we made a groove. From extracted expanded tube zones were made samples for corrosion tests in order to establish the corrosion rate, corrosion potential and corrosion current in working mediums such as hydrofining oil and industrial water at different temperatures. The corrosion rate values and the temperature influence are important to evaluate joints durability and also the results obtained shows that the boring tube sheet shape with a groove on hole tube shape presents a better corrosion behavior then the shape with smooth hole tube sheet.

  18. Tube spacer grid for a heat-exchanger tube bundle

    International Nuclear Information System (INIS)

    Scheidl, H.

    1976-01-01

    A tube spacer grid for a heat-exchanger tube bundle is formed by an annular grid frame having a groove formed in its inner surface in which the interspaced grid bars have their ends positioned and held in interspaced relationship by short sections of tubes passed through holes axially formed in the grid frame so that the tubes are positioned between the ends of the grid bars in the grooves. The tube sections may be cut from the same tubes used to form the tube bundle. 5 claims, 3 drawing figures

  19. Effect of Nebivolol on tone of tracheal muscle of guinea pig

    International Nuclear Information System (INIS)

    Shaukat, A.; Sharif, M.; Najmi, M.H.

    2015-01-01

    Background: The use of β-blockers is limited by adverse effects such as bronchospasm in asthmatics. Third generation beta-blockers such as nebivolol may show better tolerability in asthmatic subjects because they lack β-blocker induced bronchoconstriction. Method: Effects of nebivolol on the tracheal muscle strips prepared from ovalbumin-sensitised guinea pigs of both sexes were studied. Two sets of experiments were designed after dividing the animals randomly into two groups. Using oxygenated Krebs-Henseleit solution as the nutrient medium, the trachealis muscle activity was measured with isometric force displacement transducer and recorded on 4-channel Oscillograph. Results: Nebivolol 10(-6) M did not produce significant effect on contractions evoked by histamine in concentrations ranging from 10/su -7/ M to 10/sup -3/ M. The mean of amplitude of contraction for different concentrations of histamine were calculated and compared with the group treated with histamine only. Mean of amplitude of contraction, percent responses and percent deviations when compared with the control group were insignificant (p>0.05). Conclusion: Nebivolol did not affect the tone of airway smooth muscle in ovalbumin-sensitised guinea pigs. Nebivolol may be considered safe in patients with airway disease however, further clinical evaluation and exploratory work is required. (author)

  20. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Mohsen Mirmohammad-Sadeghi

    2017-01-01

    Full Text Available Background: Chest tubes are used in every case of coronary artery bypass grafting (CABG to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. Materials and Methods: This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. Results: The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group (P = 0.001, but the trend of pain score between groups was not significantly different (P = 0.097. The frequency of tamponade and atrial fibrillation (AF were significantly lower in Jackson-Pratt drain group (P < 0.05. Conclusion: The Jackson-Pratt drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.