WorldWideScience

Sample records for control tracheal tube

  1. Comparison of Effectiveness of Betamethasone gel Applied to the Tracheal Tube and IV Dexamethasone on Postoperative Sore Throat: A Randomized Controlled Trial.

    Science.gov (United States)

    Tabari, Masumeh; Soltani, Ghasem; Zirak, Nahid; Alipour, Moammad; Khazaeni, Kamran

    2013-09-01

    Postoperative sore throat is a common complaint in patients with endotracheal intubation and has potentially dangerous complications. This randomized controlled trial study investigated the incidence of postoperative sore throat after general anesthesia when betamethasone gel is applied to a tracheal tube compared with when IV dexamethasone is prescribed. Two hundred and twenty five American Society of Anesthesiologist (ASA)-class I and II patients undergoing elective abdominal surgery with tracheal intubation were randomly divided into three groups: betamethasone gel, intravenous (IV) dexamethasone, and control groups. In the post-anesthesia care unit, a blinded anesthesiologist interviewed all patients regarding postoperative sore throat at 1,6, and 24 hours after surgery. The incidence of sore throat was significantly lower in the betamethasone gel group compared with the IV dexamethasone and control groups, 1, 6, and 24 hours after surgery. In the first day after surgery 10.7% of the betamethasone group had sore throat whereas 26.7% of the IV dexamethasone group and 30.7% of the control group had sore throat. Bucking before extubation was observed in 14(18.4%), 8(10.4%), and 9(12.2%) patients, in the IV dexamethasone, betamethasone gel, and control group, respectively. We concluded that wide spread application of betamethasone gel over tracheal tubes effectively mitigates postoperative sore throat, compared with IV dexamethasone application.

  2. Comparison of Effectiveness of Betamethasone gel Applied to the Tracheal Tube and IV Dexamethasone on Postoperative sore Throat: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Masoomeh Tabari

    2013-10-01

    Full Text Available Introduction: Postoperative sore throat is a common complaint in patients with endotracheal intubation and has potentially dangerous complications. This randomized controlled trial study investigated the incidence of postoperative sore throat after general anesthesia when betamethasone gel is applied to a tracheal tube compared with when IV dexamethasone is prescribed.   Materials and Methods: Two hundred and twenty five American Society of Anesthesiologist (ASA-class I and II patients undergoing elective abdominal surgery with tracheal intubation were randomly divided into three groups: betamethasone gel, intravenous (IV dexamethasone, and control groups. In the post-anesthesia care unit, a blinded anesthesiologist interviewed all patients regarding postoperative sore throat at 1,6, and 24 hours after surgery.   Results: The incidence of sore throat was significantly lower in the betamethasone gel group compared with the IV dexamethasone and control groups, 1, 6, and 24 hours after surgery. In the first day after surgery 10.7% of the betamethasone group had sore throat whereas 26.7% of the IV dexamethasone group and 30.7% of the control group had sore throat. Bucking before extubation was observed in 14(18.4%, 8(10.4%, and 9(12.2% patients, in the IV dexamethasone, betamethasone gel, and control group, respectively.   Conclusion:  We concluded that wide spread application of betamethasone gel over tracheal tubes effectively mitigates postoperative sore throat, compared with IV dexamethasone application.

  3. 21 CFR 868.5795 - Tracheal tube cleaning brush.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheal tube cleaning brush. 868.5795 Section 868.5795 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5795 Tracheal tube cleaning brush. (a...

  4. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    Science.gov (United States)

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  5. Tracheal palpation to assess endotracheal tube depth: an exploratory study.

    Science.gov (United States)

    McKay, William P; Klonarakis, Jim; Pelivanov, Vladko; O'Brien, Jennifer M; Plewes, Chris

    2014-03-01

    Correct placement of the endotracheal tube (ETT) occurs when the distal tip is in mid-trachea. This study compares two techniques used to place the ETT at the correct depth during intubation: tracheal palpation vs placement at a fixed depth at the patient's teeth. With approval of the Research Ethics Board, we recruited American Society of Anesthesiologists physical status I-II patients scheduled for elective surgery with tracheal intubation. Clinicians performing the tracheal intubations were asked to "advance the tube slowly once the tip is through the cords". An investigator palpated the patient's trachea with three fingers spread over the trachea from the larynx to the sternal notch. When the ETT tip was felt in the sternal notch, the ETT was immobilized and its position was determined by fibreoptic bronchoscopy. The position of the ETT tip was compared with our hospital standard, which is a depth at the incisors or gums of 23 cm for men and 21 cm for women. The primary outcome was the incidence of correct placement. Correct placement of the ETT was defined as a tip > 2.5 cm from the carina and > 3.5 cm below the vocal cords. Movement of the ETT tip was readily palpable in 77 of 92 patients studied, and bronchoscopy was performed in 85 patients. Placement by tracheal palpation resulted in more correct placements (71 [77%]; 95% confidence interval [CI] 74 to 81) than hospital standard depth at the incisors or gums (57 [61%]; 95% CI 58 to 66) (P = 0.037). The mean (SD) placement of the ETT tip in palpable subjects was 4.1 (1.7) cm above the carina, 1.9 cm (1.5-2.3 cm) below the ideal mid-tracheal position. Tracheal palpation requires no special equipment, takes only a few seconds to perform, and may improve ETT placement at the correct depth. Further studies are warranted.

  6. Difficulty with cuff deflation of reinforced tracheal tube caused by inflation line occlusion with silk thread ligation and fixation.

    Science.gov (United States)

    Gotoh, Sayoko; Sugiyama, Daisuke; Imai, Eriko; Kawamata, Mikito

    2015-03-05

    A reinforced tracheal tube, ligated with silk threads, was inserted into a tracheostomy orifice and fixed to the skin. The cuff inflation line of the reinforced tracheal tube became occluded. Reinforced 'armoured' tracheal tubes have a spiral of wire embedded into the wall of the tube to give strength and flexibility, and may be sharply bent without compromising the tube lumen. The tracheal cuff attached to the tube is inflated by injecting air through a narrow-diameter tube welded to the outside of the tracheal tube. When a reinforced tracheal tube is ligated and fixed with silk threads, it should be confirmed whether the tracheal tube cuff can be deflated and inflated after fixation. Moreover, because occlusion can be eliminated by removing all silk threads used to ligate a tracheal tube, they should be removed before extubation. 2015 BMJ Publishing Group Ltd.

  7. Drosophila convoluted/dALS is an essential gene required for tracheal tube morphogenesis and apical matrix organization.

    Science.gov (United States)

    Swanson, Lianna E; Yu, Marcus; Nelson, Kevin S; Laprise, Patrick; Tepass, Ulrich; Beitel, Greg J

    2009-04-01

    Insulin-like growth factors (IGFs) control cell and organism growth through evolutionarily conserved signaling pathways. The mammalian acid-labile subunit (ALS) is a secreted protein that complexes with IGFs to modulate their activity. Recent work has shown that a Drosophila homolog of ALS, dALS, can also complex with and modulate the activity of a Drosophila IGF. Here we report the first mutations in the gene encoding dALS. Unexpectedly, we find that these mutations are allelic to a previously described mutation in convoluted (conv), a gene required for epithelial morphogenesis. In conv mutants, the tubes of the Drosophila tracheal system become abnormally elongated without altering tracheal cell number. conv null mutations cause larval lethality, but do not disrupt several processes required for tracheal tube size control, including septate junction formation, deposition of a lumenal/apical extracellular matrix, and lumenal secretion of Vermiform and Serpentine, two putative matrix-modifying proteins. Clearance of lumenal matrix and subcellular localization of clathrin also appear normal in conv mutants. However, we show that Conv/dALS is required for the dynamic organization of the transient lumenal matrix and normal structure of the cuticle that lines the tracheal lumen. These and other data suggest that the Conv/dALS-dependent tube size control mechanism is distinct from other known processes involved in tracheal tube size regulation. Moreover, we present evidence indicating that Conv/dALS has a novel, IGF-signaling independent function in tracheal morphogenesis.

  8. Tracheal tube and laryngeal mask cuff pressure during anaesthesia - mandatory monitoring is in need

    DEFF Research Database (Denmark)

    Rokamp, K.Z.; Secher, N.H.; Møller, Ann

    2010-01-01

    ABSTRACT: BACKGROUND: To prevent endothelium and nerve lesions, tracheal tube and laryngeal mask cuff pressure is to be maintained at a low level and yet be high enough to secure air sealing. METHOD: In a prospective quality-control study, 201 patients undergoing surgery during anaesthesia (without...... the use of nitrous oxide) were included for determination of the cuff pressure of the tracheal tubes and laryngeal masks. RESULTS: In the 119 patients provided with a tracheal tube, the median cuff pressure was 30 (range 8 - 100) cm H2O and the pressure exceeded 30 cm H2O (upper recommended level) for 54...... patients. In the 82 patients provided with a laryngeal mask, the cuff pressure was 95 (10 - 121) cm H2O and above 60 cm H2O (upper recommended level) for 56 patients and in 34 of these patients, the pressure exceeded the upper cuff gauge limit (120 cm H2O). There was no association between cuff pressure...

  9. Long-term outcome of conventional endotracheal tube balloon dilation of tracheal stenosis in a dog

    OpenAIRE

    Kahane, Nili; Segev, Gilad

    2014-01-01

    This report describes a successful dilation of tracheal stenosis in a 16-year-old dog using a conventional endotracheal tube balloon. This technique should be considered as palliative treatment when owners decline other therapeutic options.

  10. Long-term outcome of conventional endotracheal tube balloon dilation of tracheal stenosis in a dog.

    Science.gov (United States)

    Kahane, Nili; Segev, Gilad

    2014-01-01

    This report describes a successful dilation of tracheal stenosis in a 16-year-old dog using a conventional endotracheal tube balloon. This technique should be considered as palliative treatment when owners decline other therapeutic options.

  11. Use of the silicone tracheal T-tube for tracheostenosis or tracheomalacia.

    Science.gov (United States)

    Liu, H C; Wang, L S; Fahn, H J; Lee, Y C; Lu, C C; Chan, K H; Huang, M H

    1996-09-01

    Tracheobtenosib and tracheomalacia are trivial diseases. The conventional choice of managements with tracheostomy, either temporary or long-term usage, can only partially resolve the problems of airway obstruction. Silicone tracheal T-tube presents a substitute for it. We present 5 patients with tracheostenosis or tracheomalacia managed with nine procedures of long silicone Montgomery T-tube prothesis between 1984 and 1994 in VGH-Taipei. The primary diagnosis included tracheal injury (2), postintubation tracheal stenosis (2), and stenosis due to endotracheal tuberculosis (1). Three patients received a long segmental T-tube for permanent endotracheal stenting and the other two patients used T-tube insertion for temporary stenting of the trachea for 7 and 11 months, respectively, with satisfactory results. All patients got immediate benefit from the prothesis in respiration with simple postoperative care. Two patients with temporary T-tube placement had it successfully removed in 7 and 11 months, respectively. Placement of the T-tube for subglottic stenosis also protected the function of phonation. The tracheal T-tube restored airway patency reliably with good long-term results and could be the preferred management of chronic upper airway obstructive disease not amenable to surgical repair. The most common complication was airway obstruction caused by either granulations or sticky mucoid substance. Three patients and six tubes (60%) developed granulation obstruction and the average duration of granuloma formation was 7.7 months. Laser phototherapy or surgical intervention, such as tracheoplasty, with change of the T-tube was carried out for granuloma obstruction. T-tube is a good endoprothesis for tracheostenosis and tracheomalacia with minimal complication for cases of long tracheostenosis or complex tracheal injury.

  12. [Use of the Pentax-AWS videolaryngoscope for bougie-assisted exchange of tracheal tubes].

    Science.gov (United States)

    Kishii, Miki; Asai, Takashi; Nagata, Atsushi; Shingu, Koh

    2009-06-01

    A gum elastic bougie can be useful for tube exchange. One major problem with this technique is that it may not possible to pass a new tube over the bougie into the trachea, because the tip of the tube can collide with tissues around the glottis. We report a case in which tube exchange using the bougie was difficult, but the Pentax-AWS videolaryngoscope enabled tracheal intubation. In a 62-year-old trauma patient with head and neck stabilized using a Halo vest, was scheduled for emergency fixation of the neck. Exchange of a polyvinylchloride tube to a reinforced tube was planned. A bougie was passed through the old tube, removing the tube, and a new tube was advanced over the bougie, but it was impossible to advance the tube into the trachea. Insertion of a Macintosh laryngoscope did not enable intubation. The new tube was removed from the bougie, attached to the Pentax-AWS videolaryngoscope, and the tube (with the Pentax-AWS) was passed over the bougie. Although it was not possible to see the glottis with the Pentax-AWS, the tube was easily advanced over the bougie into the trachea. Operation went on uneventfully. We believe that, when it is difficult to advance a tracheal tube over a tube exchanger, the use of the Pentax-AWS may facilitate intubation.

  13. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation.

    Science.gov (United States)

    Chou, Hao-Chang; Chong, Kah-Meng; Sim, Shyh-Shyong; Ma, Matthew Huei-Ming; Liu, Shih-Hung; Chen, Nai-Chuan; Wu, Meng-Che; Fu, Chia-Ming; Wang, Chih-Hung; Lee, Chien-Chang; Lien, Wan-Ching; Chen, Shyr-Chyr

    2013-12-01

    This study aimed to evaluate the accuracy of tracheal ultrasonography for assessing endotracheal tube position during cardiopulmonary resuscitation (CPR). We performed a prospective observational study of patients undergoing emergency intubation during CPR. Real-time tracheal ultrasonography was performed during the intubation with the transducer placed transversely just above the suprasternal notch, to assess for endotracheal tube positioning and exclude esophageal intubation. The position of trachea was identified by a hyperechoic air-mucosa (A-M) interface with posterior reverberation artifact (comet-tail artifact). The endotracheal tube position was defined as endotracheal if single A-M interface with comet-tail artifact was observed. Endotracheal tube position was defined as intraesophageal if a second A-M interface appeared, suggesting a false second airway (double tract sign). The gold standard of correct endotracheal intubation was the combination of clinical auscultation and quantitative waveform capnography. The main outcome was the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR. Among the 89 patients enrolled, 7 (7.8%) had esophageal intubations. The sensitivity, specificity, positive predictive value, and negative predictive value of tracheal ultrasonography were 100% (95% confidence interval [CI]: 94.4-100%), 85.7% (95% CI: 42.0-99.2%), 98.8% (95% CI: 92.5-99.0%) and 100% (95% CI: 54.7-100%), respectively. Positive and negative likelihood ratios were 7.0 (95% CI: 1.1-43.0) and 0.0, respectively. Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during CPR without the need for interruption of chest compression. Tracheal ultrasonography in resuscitation management may serve as a powerful adjunct in trained hands. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. A visual stethoscope to detect the position of the tracheal tube.

    Science.gov (United States)

    Kato, Hiromi; Suzuki, Akira; Nakajima, Yoshiki; Makino, Hiroshi; Sanjo, Yoshimitsu; Nakai, Takayoshi; Shiraishi, Yoshito; Katoh, Takasumi; Sato, Shigehito

    2009-12-01

    Advancing a tracheal tube into the bronchus produces unilateral breath sounds. We created a Visual Stethoscope that allows real-time fast Fourier transformation of the sound signal and 3-dimensional (frequency-amplitude-time) color rendering of the results on a personal computer with simultaneous processing of 2 individual sound signals. The aim of this study was to evaluate whether the Visual Stethoscope can detect bronchial intubation in comparison with auscultation. After induction of general anesthesia, the trachea was intubated with a tracheal tube. The distance from the incisors to the carina was measured using a fiberoptic bronchoscope. While the anesthesiologist advanced the tracheal tube from the trachea to the bronchus, another anesthesiologist auscultated breath sounds to detect changes of the breath sounds and/or disappearance of bilateral breath sounds for every 1 cm that the tracheal tube was advanced. Two precordial stethoscopes placed at the left and right sides of the chest were used to record breath sounds simultaneously. Subsequently, at a later date, we randomly entered the recorded breath sounds into the Visual Stethoscope. The same anesthesiologist observed the visualized breath sounds on the personal computer screen processed by the Visual Stethoscope to examine changes of breath sounds and/or disappearance of bilateral breath sound. We compared the decision made based on auscultation with that made based on the results of the visualized breath sounds using the Visual Stethoscope. Thirty patients were enrolled in the study. When irregular breath sounds were auscultated, the tip of the tracheal tube was located at 0.6 +/- 1.2 cm on the bronchial side of the carina. Using the Visual Stethoscope, when there were any changes of the shape of the visualized breath sound, the tube was located at 0.4 +/- 0.8 cm on the tracheal side of the carina (P Stethoscope (not significant). During advancement of the tracheal tube, alterations of the shape of the

  15. Management of dogs and cats with endotracheal tube tracheal foreign bodies

    Science.gov (United States)

    Nutt, Laura K.; Webb, Jinelle A.; Prosser, Kirsten J.; Defarges, Alice

    2014-01-01

    Two cats and 3 dogs were treated for an endotracheal tube tracheal foreign body (ETFB) during recovery from general anesthesia. Bronchoscopy was used to remove the ETFB. Animals were clinically normal at discharge. While rare, ETFB can occur upon recovery from anesthesia. Bronchoscopy is an effective way to remove ETFB. PMID:24891640

  16. Complete subglottic tracheal stenosis managed with rigid bronchoscopy and T-tube placement

    Directory of Open Access Journals (Sweden)

    Kuruswamy Thurai Prasad

    2016-01-01

    Full Text Available Surgery is the preferred treatment modality for benign tracheal stenosis. Interventional bronchoscopy is used as a bridge to surgery or in instances when surgery is not feasible or has failed. Stenosis in the subglottic trachea is particularly a treatment challenge, in view of its proximity to the vocal cords. Herein, we describe a patient with complete tracheal stenosis in the subglottic region, which developed after prolonged intubation and mechanical ventilation. The patient developed recurrent stenosis despite multiple surgical and endoscopic procedures. We were able to manage the patient successfully with rigid bronchoscopy and Montgomery T-tube placement.

  17. Engineered cartilaginous tubes for tracheal tissue replacement via self-assembly and fusion of human mesenchymal stem cell constructs.

    Science.gov (United States)

    Dikina, Anna D; Strobel, Hannah A; Lai, Bradley P; Rolle, Marsha W; Alsberg, Eben

    2015-06-01

    There is a critical need to engineer a neotrachea because currently there are no long-term treatments for tracheal stenoses affecting large portions of the airway. In this work, a modular tracheal tissue replacement strategy was developed. High-cell density, scaffold-free human mesenchymal stem cell-derived cartilaginous rings and tubes were successfully generated through employment of custom designed culture wells and a ring-to-tube assembly system. Furthermore, incorporation of transforming growth factor-β1-delivering gelatin microspheres into the engineered tissues enhanced chondrogenesis with regard to tissue size and matrix production and distribution in the ring- and tube-shaped constructs, as well as luminal rigidity of the tubes. Importantly, all engineered tissues had similar or improved biomechanical properties compared to rat tracheas, which suggests they could be transplanted into a small animal model for airway defects. The modular, bottom up approach used to grow stem cell-based cartilaginous tubes in this report is a promising platform to engineer complex organs (e.g., trachea), with control over tissue size and geometry, and has the potential to be used to generate autologous tissue implants for human clinical applications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.

    Science.gov (United States)

    Kumar, R D C; Hirsch, N P

    2011-11-01

    Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  19. Tracheal rupture after misplacement of Sengstaken-Blakemore tube ...

    African Journals Online (AJOL)

    The balloon were immediately deflated and a chest X-ray was performed, showing the tube in the right bronchus airway (A), so it was withdrawn. Right pneumothorax appeared and was treated with an intercostal drainage. The patient required orotracheal intubation and a CT scan was performed to show the rupture level ...

  20. Middle finger length-based tracheal intubation depth improves the rate of appropriate tube placement in children.

    Science.gov (United States)

    Zhou, Qing-he; Xiao, Wang-pin; Zhou, Hong-mei

    2015-11-01

    It is challenging for anesthetists to determine the optimal tracheal intubation depth in children. We hypothesize that a measure three times the length of the middle finger can be used for predicting tracheal tube depth in children. Eighty-six children (4-14 years of age) were included in this study. After the children were anesthetized, a fiberoptic bronchoscope (FOB) was inserted into the trachea, the lengths from the upper incisor teeth to carina and vocal cords were measured, and a suitably sized cuffed tracheal tube was inserted into the trachea. Age-based and middle finger length-based formulas were used to determine the tracheal intubation depth. All 86 children enrolled were included in this study. Compared with the age-based intubation, the rate of appropriate tube placement was higher for middle finger length-based intubation (88.37% vs 66.28%, P = 0.001). The proximal intubation rate was lower in middle finger length-based intubation (4.65% vs 32.56%, P tube depth was larger than that between age and optimal tracheal tube depth (0.883 vs 0.845). Our data indicate that the appropriate tube placement rate can be improved by using three times the middle finger length as the tracheal intubation depth in children. © 2015 John Wiley & Sons Ltd.

  1. Management of Benign Tracheal Stenosis by Small-diameter Tube-assisted Bronchoscopic Balloon Dilatation

    Directory of Open Access Journals (Sweden)

    Yi-Lin Liang

    2015-01-01

    Full Text Available Background: A limitation of bronchoscopic balloon dilatation (BBD is that airflow must be completely blocked for as long as possible during the operation. However, the patient often cannot hold his or her breath for a long period affecting the efficacy of the procedure. In this study, we used an extra-small-diameter tube to provide assisted ventilation to patients undergoing BBD and assessed the efficacy and safety of this technique. Methods: Bronchoscopic balloon dilatation was performed in 26 patients with benign tracheal stenosis using an extra-small-diameter tube. The tracheal diameter, dyspnea index, blood gas analysis results, and complications were evaluated before and after BBD. Statistical analyses were performed by SPSS version 16.0 for Windows (SPSS, Inc., Chicago, IL, USA. Results: Sixty-three BBD procedures were performed in 26 patients. Dyspnea immediately improved in all patients after BBD. The tracheal diameter significantly increased from 5.5 ± 1.5 mm to 13.0 ± 1.3 mm (P < 0.001, and the dyspnea index significantly decreased from 3.4 ± 0.8 to 0.5 ± 0.6 (P < 0.001. There was no significant change in the partial pressure of oxygen during the operation (before, 102.5 ± 27.5 mmHg; during, 96.9 ± 30.4 mmHg; and after, 97.2 ± 21.5 mmHg; P = 0.364, but there was slight temporary retention of carbon dioxide during the operation (before, 43.5 ± 4.2 mmHg; during, 49.4 ± 6.8 mmHg; and after, 40.1 ± 3.9 mmHg; P < 0.001. Conclusion: Small-diameter tube-assisted BBD is an effective and safe method for the management of benign tracheal stenosis.

  2. Subcellular trafficking of FGF controls tracheal invasion of Drosophila flight muscle.

    Science.gov (United States)

    Peterson, Soren J; Krasnow, Mark A

    2015-01-15

    To meet the extreme oxygen demand of insect flight muscle, tracheal (respiratory) tubes ramify not only on its surface, as in other tissues, but also within T-tubules and ultimately surrounding every mitochondrion. Although this remarkable physiological specialization has long been recognized, its cellular and molecular basis is unknown. Here, we show that Drosophila tracheoles invade flight muscle T-tubules through transient surface openings. Like other tracheal branching events, invasion requires the Branchless FGF pathway. However, localization of the FGF chemoattractant changes from all muscle membranes to T-tubules as invasion begins. Core regulators of epithelial basolateral membrane identity localize to T-tubules, and knockdown of AP-1γ, required for basolateral trafficking, redirects FGF from T-tubules to surface, increasing tracheal surface ramification and preventing invasion. We propose that tracheal invasion is controlled by an AP-1-dependent switch in FGF trafficking. Thus, subcellular targeting of a chemoattractant can direct outgrowth to specific domains, including inside the cell. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Cuff depth and continuous chest auscultation method for determination of tracheal tube insertion depth in nasal intubation: observational study.

    Science.gov (United States)

    Ouchi, Kentaro; Sugiyama, Kazuna

    2016-04-01

    Incorrect endobronchial placement of the tracheal tube can lead to serious complications. Hence, it is necessary to determine the accuracy of tracheal tube positioning. Markers are included on tracheal tubes, in the process of their manufacture, as indicators of approximate intubation depth. In addition, continuous chest auscultation has been used for determining the proper position of the tube. We examined insertion depth using the cuff depth and continuous chest auscultation method (CC method), compared with insertion depth determined by the marker method, to assess the accuracy of these methods. After induction of anesthesia, tracheal intubation was performed in each patient. In the CC method, the depth of tube insertion was measured when the cuff had passed through the glottis, and again when breath sounds changed in quality; the depth of tube insertion was determined from these values. In the marker method, the depth of tube insertion was measured and determined when the marker of the tube had reached the glottis, using insertion depth according to the marker as an index. Insertion depth by the marker method was 26.6 ± 1.2 cm and by the CC method was 28.0 ± 1.2 cm (P < 0.0001). The CC method indicated a significantly greater depth than the marker method. This study determined the safe range of tracheal tube placement. Tube positions determined by the CC method were about 1 cm deeper than those determined by the marker. This information is important to prevent accidental one-lung ventilation and accidental extubation. UMIN No. UMIN000011375.

  4. Variation in the mechanical properties of tracheal tubes in the American cockroach

    International Nuclear Information System (INIS)

    Becker, Winston R; Webster, Matthew R; De Vita, Raffaella; Socha, John J

    2014-01-01

    The insect cuticle serves the protective role of skin and the supportive role of the skeleton while being lightweight and flexible to facilitate flight. The smart design of the cuticle confers camouflage, thermo-regulation, communication, self-cleaning, and anti-wetting properties to insects. The mechanical behavior of the internal cuticle of the insect in tracheae remains largely unexplored due to their small size. In order to characterize the material properties of insect tracheae and understand their role during insect respiration, we conducted tensile tests on ring sections of tracheal tubes of American cockroaches (Periplaneta americana). A total of 33 ring specimens collected from 14 tracheae from the upper thorax of the insects were successfully tested. The ultimate tensile strength (22.6 ± 13.3 MPa), ultimate strain (1.57 ± 0.68%), elastic modulus (1740 ± 840 MPa), and toughness (0.175 ± 0.156 MJ m −3 ) were measured. We examined the high variance in mechanical properties statistically and demonstrated that ring sections excised from the same trachea exhibit comparable mechanical properties. Our results will form the basis for future studies aimed at determining the structure–function relationship of insect tracheal tubes, ultimately inspiring the design of multi-functional materials and structures. (technical note)

  5. An evaluation of the retromolar space for oral tracheal tube placement for maxillofacial surgery in children.

    Science.gov (United States)

    Arora, Suman; Rattan, Vidya; Bhardwaj, Neerja

    2006-11-01

    The eruption of the first and second permanent molar teeth may influence the size of the retromolar space. In this study we evaluated the adequacy of the retromolar space for retromolar intubation and any effect of eruption of the first and second permanent molar teeth on this space in children. Children 3-15 yr of age, undergoing surgery other than facial surgery were included for evaluation of the retromolar space. After standard oral tracheal intubation, the endotracheal tube was shifted to the retromolar space and the mandible was slowly closed to achieve centric occlusion. At the same time, any increase in airway resistance or decrease in oxygen saturation was noted. In the second part of the study, the feasibility of retromolar intubation in pediatric patients undergoing maxillofacial surgery with intraoperative maxillomandibular fixation was assessed. There was enough space for endotracheal tube placement in the retromolar region. The eruption of the first and second permanent molar teeth did not affect intubation. It was possible to achieve centric occlusion in 79 of 80 children with the endotracheal tube positioned in the retromolar space. Retromolar intubation was successfully accomplished in six pediatric patients undergoing maxillomandibular fixation and maxillofacial surgery. The retromolar space can be safely used for intubation in children when intraoperative maxillomandibular fixation, and simultaneous access to the nose and oral cavity are needed.

  6. Strategies to prevent ventilation-associated pneumonia: the effect of cuff pressure monitoring techniques and tracheal tube type on aspiration of subglottic secretions: an in-vitro study.

    Science.gov (United States)

    Carter, Eleanor L; Duguid, Alasdair; Ercole, Ari; Matta, Basil; Burnstein, Rowan M; Veenith, Tonny

    2014-03-01

    Ventilation-associated pneumonia (VAP) is the commonest nosocomial infection in intensive care. Implementation of a VAP prevention care bundle is a proven method to reduce its incidence. The UK care bundle recommends maintenance of the tracheal tube cuff pressure at 20 to 30  cmH₂O with 4-hourly pressure checks and use of tracheal tubes with subglottic aspiration ports in patients admitted for more than 72  h. To evaluate the effects of tracheal tube type and cuff pressure monitoring technique on leakage of subglottic secretions past the tracheal tube cuff. Bench-top study. Laboratory. A model adult trachea with simulated subglottic secretions was intubated with a tracheal tube with the cuff inflated to 25  cmH₂O. Experiments were conducted using a Portex Profile Soft Seal tracheal tube with three cuff pressure monitoring strategies and using a Portex SACETT tracheal tube with intermittent cuff pressure checks. Rate of simulated secretion leakage past the tracheal tube cuff. Mean ± SD leakage of fluid past the Profile Soft Seal tracheal tube cuff was 2.25 ± 1.49  ml  min⁻¹ with no monitoring of cuff pressure, 2.98 ± 1.63  ml  min⁻¹ with intermittent cuff pressure monitoring and 3.83 ± 2.17  ml  min⁻¹ with continuous cuff pressure monitoring (P aspiration port and aspirating the simulated secretions prior to intermittent cuff pressure checks reduced the leakage rate to 0.50 ± 0.48  ml  min⁻¹ (P aspiration port. Further evaluation of medical device performance is needed in order to design more effective VAP prevention strategies.

  7. Laryngoscope and a new tracheal tube assist lightwand intubation in difficult airways due to unstable cervical spine.

    Directory of Open Access Journals (Sweden)

    Cai-neng Wu

    Full Text Available The WEI Jet Endotracheal Tube (WEI JET is a new tracheal tube that facilitates both oxygenation and ventilation during the process of intubation and assists tracheal intubation in patients with difficult airway. We evaluated the effectiveness and usefulness of the WEI JET in combination with lightwand under direct laryngoscopy in difficult tracheal intubation due to unstable cervical spine.Ninety patients with unstable cervical spine disorders (ASA I-III with general anaesthesia were included and randomly assigned to three groups, based on the device used for intubation: lightwand only, lightwand under direct laryngoscopy, lightwand with WEI JET under direct laryngoscopy.No statistically significant differences were detected among three groups with respect to demographic characteristics and C/L grade. There were statistically significant differences between three groups for overall intubation success rate (p = 0.015 and first attempt success rate (p = 0.000. The intubation time was significantly longer in the WEI group (110.8±18.3 s than in the LW group (63.3±27.5 s, p = 0.000 and DL group (66.7±29.4 s, p = 0.000, but the lowest SpO2 in WEI group was significantly higher than other two groups (p<0.01. The WEI JET significantly reduced successful tracheal intubation attempts compared to the LW group (p = 0.043. The severity of sore throat was similar in three groups (p = 0.185.The combined use of WEI JET under direct laryngoscopy helps to assist tracheal intubation and improves oxygenation during intubation in patients with difficult airway secondary to unstable spine disorders.Chinese Clinical Trial Registry ChiCTR-TRC-14005141.

  8. Impact of tracheal cuff shape on microaspiration of gastric contents in intubated critically ill patients: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Jaillette, Emmanuelle; Brunin, Guillaume; Girault, Christophe; Zerimech, Farid; Chiche, Arnaud; Broucqsault-Dedrie, Céline; Fayolle, Cyril; Minacori, Franck; Alves, Isabelle; Barrailler, Stephanie; Robriquet, Laurent; Tamion, Fabienne; Delaporte, Emmanuel; Thellier, Damien; Delcourte, Claire; Duhamel, Alain; Nseir, Saad

    2015-09-25

    Ventilator-associated pneumonia (VAP) is the most common infection in intubated critically ill patients. Microaspiration of the contaminated gastric and oropharyngeal secretions is the main mechanism involved in the pathophysiology of VAP. Tracheal cuff plays an important role in stopping the progression of contaminated secretions into the lower respiratory tract. Previous in vitro studies suggested that conical cuff shape might be helpful in improving tracheal sealing. However, clinical studies found conflicting results. The aim of this study is to determine the impact of conical tracheal cuff shape on the microaspiration of gastric contents in critically ill patients. This prospective cluster randomized controlled crossover open-label trial is currently being conducted in ten French intensive care units (ICUs). Patients are allocated to intubation with a polyvinyl chloride (PVC) standard (barrel)-shaped or a PVC conical-shaped tracheal tube. The primary objective is to determine the impact of the conical shaped tracheal cuff on abundant microaspiration of gastric contents. Secondary outcomes include the incidence of microaspiration of oropharyngeal secretions, tracheobronchial colonization, VAP and ventilator-associated events. Abundant microaspiration is defined as the presence of pepsin at significant level (>200 ng/ml) in at least 30 % of the tracheal aspirates. Pepsin and amylase are quantitatively measured in all tracheal aspirates during the 48 h following inclusion. Quantitative tracheal aspirate culture is performed at inclusion and twice weekly. We plan to recruit 312 patients in the participating ICUs. BEST Cuff is the first randomized controlled study evaluating the impact of PVC tracheal-cuff shape on gastric microaspirations in patients receiving invasive mechanical ventilation. Enrollment began in June 2014 and is expected to end in October 2015. ClinicalTrials.gov Identifier: NCT01948635 (registered 31 August 2013).

  9. Interactions between Type III receptor tyrosine phosphatases and growth factor receptor tyrosine kinases regulate tracheal tube formation in Drosophila

    Directory of Open Access Journals (Sweden)

    Mili Jeon

    2012-04-01

    The respiratory (tracheal system of the Drosophila melanogaster larva is an intricate branched network of air-filled tubes. Its developmental logic is similar in some ways to that of the vertebrate vascular system. We previously described a unique embryonic tracheal tubulogenesis phenotype caused by loss of both of the Type III receptor tyrosine phosphatases (RPTPs, Ptp4E and Ptp10D. In Ptp4E Ptp10D double mutants, the linear tubes in unicellular and terminal tracheal branches are converted into bubble-like cysts that incorporate apical cell surface markers. This tube geometry phenotype is modulated by changes in the activity or expression of the epidermal growth factor receptor (Egfr tyrosine kinase (TK. Ptp10D physically interacts with Egfr. Here we demonstrate that the Ptp4E Ptp10D phenotype is the consequence of the loss of negative regulation by the RPTPs of three growth factor receptor TKs: Egfr, Breathless and Pvr. Reducing the activity of any of the three kinases by tracheal expression of dominant-negative mutants suppresses cyst formation. By competing dominant-negative and constitutively active kinase mutants against each other, we show that the three RTKs have partially interchangeable activities, so that increasing the activity of one kinase can compensate for the effects of reducing the activity of another. This implies that SH2-domain downstream effectors that are required for the phenotype are likely to be able to interact with phosphotyrosine sites on all three receptor TKs. We also show that the phenotype involves increases in signaling through the MAP kinase and Rho GTPase pathways.

  10. Morphological findings in the tracheal epithelium of dogs exposed to the inhalation of poorly conditioned gases under use of an endotracheal tube or laryngeal mask airway.

    Science.gov (United States)

    Dias, Norimar Hernandes; Braz, José Reinaldo Cerqueira; Defaveri, Júlio; Carvalho, Lídia Raquel; Martins, Regina Helena Garcia

    2011-10-01

    To study morphological findings in the tracheal epithelium of dogs exposed to the inhalation of poorly conditioned gases under use of an endotracheal tube (ET) or laryngeal mask airway (LMA). Twelve dogs randomly were allocated to two groups: ET group (n-6) and LMA group (n-6), anaesthetized and mechanically ventilated, without CO(2) reabsorption. Haemodynamic and ventilatory parameters, tympanic temperature, temperature, relative and absolute humidity of the ambient and inhaled gases were analyzed during three hours. The animals were submitted to euthanasia and biopsies were carried out along the tracheal segment to morphological study. Three healthy dogs were used to morphological control. Inhaled gas temperature was maintained between 24ºC and 26ºC, relative humidity between 10% and 12%, and absolute humidity between 2 - 3 mg H(2)O.L(-1) with no significant differences between groups. In both groups, histological analysis showed epithelial inflammation and congestion in the corion and scanning electron microscopy showed ciliary grouping and disorganization. Transmission electron microscopy showed higher alterations in ET group than LMA group as widening of cell junctions, ciliary disorientation, cytoplasmic vacuolization, nuclear abnormalities, picnosis and chromatin condensation. LMA determined less pronounced changes in the tracheal epithelium in dogs exposed to the inhalation of poorly conditioned gases.

  11. Three-finger tracheal palpation to guide endotracheal tube depth in children.

    Science.gov (United States)

    Gamble, Jonathan J; McKay, William P; Wang, Andrew F; Yip, Kinsha A; O'Brien, Jennifer M; Plewes, Christopher E

    2014-10-01

    Accurate endotracheal tube (ETT) depth is critical, especially in children. The current tools used to guide appropriate ETT depth have significant limitations. To evaluate the utility of tracheal palpation in the neck to guide appropriate ETT placement in children. A prospective observational study with a convenience sample of 50 children was conducted. During intubation, an investigator palpated the trachea with three fingertips side-by-side extending upward from the suprasternal notch. The anesthesiologist advanced the ETT slowly until palpated at the sternal notch. The investigator stated ETT palpation certainty as 'strongly felt', 'weakly felt', or 'not felt.' Final ETT position was determined by bronchoscopy and categorized as 'ETT too shallow' (tip in proximal ¼ of trachea), 'ETT too deep' (tip in distal ¼ of trachea), or 'ETT placement satisfactory' (between those extremes). Thirty boys and 20 girls undergoing dental surgery with nasal intubation were recruited (median age 4.4 years; range 2.0-10.8). The ETT (all ≥4 mm ID) was palpable at the sternal notch in all patients: 46 of 50 strongly palpable and 4 of 50 weakly palpable. The experimental methods led to satisfactory ETT placement in 49 of 50 patients, too deep in 1 of 50 patients. Compared with the Pediatrics Advanced Life Support (PALS) predictive formula, satisfactory placement would have been 41 of 50 patients (P guide ETT placement has excellent clinical performance and better guides appropriate ETT depth than the PALS formula in our study population. © 2014 John Wiley & Sons Ltd.

  12. Tracheal tube airleak in clinical practice and impact on tidal volume measurement in ventilated neonates.

    Science.gov (United States)

    Mahmoud, Ramadan A; Proquitté, Hans; Fawzy, Naglaa; Bührer, Christoph; Schmalisch, Gerd

    2011-03-01

    To determine the prevalence, size, and factors affecting tracheal tube (TT) leak in clinical practice and their influence on the displayed tidal volume (Vt) in ventilated newborn infants using uncuffed TTs. Monitoring of Vt is important for implementation of lung-protective ventilation strategies but becomes meaningless in the presence of large TT airleaks. Retrospective clinical study. Neonatal intensive care unit. Patient records of 163 neonates ventilated with Babylog 8000 for ≥ 5 hrs with a median (range) gestation age of 31.1 wks (23.3-41.9 wks) and a median birth weight of 1470 g (410-4475 g) were evaluated. : Ventilatory settings, TT leak, and Vt were recorded every 3 hrs. The lowest, median, and highest TT leaks were noted on the day the first TT leak (>5%) occurred, the day on which TT leak peaked, and the day of extubation. A TT leak of >5% was seen in 122 (75%) infants. Neonates with TT leak, compared with those without TT leak, had a longer duration of mechanical ventilation (p 40% commonly seen on the third day of mechanical ventilation. Regression analysis showed that a TT leak of 40% indicated that the displayed Vt was underestimated by 1.2 mL/kg (about 24% of target Vt). TT leak is highly variable, and TT leak of >40% with clinically relevant Vt errors occurred in nearly half of all ventilated neonates. Preterm infants of low birth weight and with small-diameter TTs ventilated for a long period were at greater risk of TT leak.

  13. Comparison between traditional and small-diameter tube-assisted bronchoscopic balloon dilatation in the treatment of benign tracheal stenosis.

    Science.gov (United States)

    Li, Li-Hua; Liang, Yi-Lin; Li, Yu; Xu, Ming-Peng; Li, Wen-Tao; Liu, Guang-Nan

    2018-03-01

    To compare the safety and efficacy between using a small-diameter tube-assisted bronchoscopic balloon dilatation (BBD) and the traditional BBD in the treatment of benign tracheal stenosis. A retrospective study included 58 patients with benign tracheal stenosis from August 2009 to December 2014 was made. The patients who underwent traditional BBD were divided into group A, and who underwent a small-diameter tube-assisted BBD were divided into group B. The tracheal diameter, dyspnea index and blood gas analysis results were detected before and after BBD. Efficacy and complications were evaluated after BBD. There were significant differences in oxygen saturation (PaO 2 ) during the operations comparing with before and after operations in group A (P = .005), while there was no significant difference in group B (P = .079). The tracheal diameter obviously increased (in group A, from 4.16 ± 1.43 mm to 12.47 ± 1.41 mm, P = .000; in group B: from 4.94 ± 1.59 mm to 12.61 ± 1.41 mm, P = .000). Dyspnea index obviously decreased (group A: from 3.21 ± 0.93 to 0.50 ± 0.59, P = .000; group B: from 3.24 ± 0.89 to 0.65 ± 0.69, P = .000). The immediately cure rate in both groups was 100%. Long-term effect was significantly better in group B than that in group A (85.3% vs 59.1%, P = .021), at the end of the follow-up period. Small-diameter tube-assisted BBD obtains better safety and long-term efficacy than the traditional BBD in the treatment of benign tracheal stenosis. However, close attention should be given to the risk of the adverse effects caused by carbon dioxide retention. © 2017 John Wiley & Sons Ltd.

  14. Control rod guide tube assemblies

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1979-01-01

    A nuclear fuel assembly including sleeves telescoped over end portions of control rod guide tubes which bear against internal shoulders of the sleeves. Upper ends of the sleeves protrude beyond a control rod guide tube spider and are locked in place by means of a resilient cellular lattice or lock that is seated in mating grooves in the outer surfaces of the sleeves. A grapple is provided for disengaging the entire lock structure spider and associated washers, springs and a grill from the end of the fuel assembly in order to enable these components to be removed and subsequently replaced on the fuel assembly after inspection and repair. (UK)

  15. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants—the impact of ventilator settings on tracheal pressure swings

    International Nuclear Information System (INIS)

    Hentschel, Roland; Buntzel, Julia; Guttmann, Josef; Schumann, Stefan

    2011-01-01

    Resistive properties of endotracheal tubes (ETTs) are particularly relevant in newborns and small infants who are generally ventilated through ETTs with a small inner diameter. The ventilation rate is also high and the inspiratory time (ti) is short. These conditions effectuate high airway flows with excessive flow acceleration, so airway resistance and inertance play an important role. We carried out a model study to investigate the impact of varying ETT size, lung compliance and ventilator settings, such as peak inspiratory pressure (PIP), positive end expiratory pressure (PEEP) and inspiratory time (ti) on the pressure–flow characteristics with respect to the resistive and inertive properties of the ETT. Pressure at the Y piece was compared to direct measurement of intratracheal pressure (P trach ) at the tip of the ETT, and pressure drop (ΔP ETT ) was calculated. Applying published tube coefficients (Rohrer's constants and inertance), P trach was calculated from ventilator readings and compared to measured P trach using the root-mean-square error. The most relevant for ΔP ETT was the ETT size, followed by (in descending order) PIP, compliance, ti and PEEP, with gas flow velocity being the principle in common for all these parameters. Depending on the ventilator settings ΔP ETT exceeded 8 mbar in the smallest 2.0 mm ETT. Consideration of inertance as an additional effect in this setting yielded a better agreement of calculated versus measured P trach than Rohrer's constants alone. We speculate that exact tracheal pressure tracings calculated from ventilator readings by applying Rohrer's equation and the inertance determination to small size ETTs would be helpful. As an integral part of ventilator software this would (1) allow an estimate of work of breathing and implementation of an automatic tube compensation, and (2) be important for gentle ventilation in respiratory care, especially of small infants, since it enables the physician to

  16. Control rod guide tube assembly

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1982-01-01

    An improved fuel assembly is described as consisting of a sleeve that engages one end of a control rod guide tube essentially fixing the guide tube to one of the fuel assembly end structures. The end of the sleeve protrudes above the surface of the end fitting. The outer surface of the sleeve has a peripheral groove that engages the resilient sides of a cellular grid or lattice shaped lock. This lock fixes the sleeve in position between the various elements that comprise the end fitting, thereby eliminating a profusion of costly and potentially troublesome nuts, threaded studs and the like that are frequently employed in the fuel assemblies that are presently in use

  17. X-ray tube current control

    International Nuclear Information System (INIS)

    Dupuis, W.A.; Resnick, T.A.

    1982-01-01

    A closed loop feedback system for controlling the current output of an x-ray tube. The system has circuitry for improving the transient response and stability of the x-ray tube current over a substantial nonlinear portion of the tube current production characteristic. The system includes a reference generator for applying adjustable step function reference signals representing desired tube currents. The system also includes means for instantaneous sensing of actual tube current. An error detector compares the value of actual and reference tube current and produces an error signal as a function of their difference. The system feedback loop includes amplification circuitry for controlling x-ray tube filament dc voltage to regulate tube current as a function of the error signal value. The system also includes compensation circuitry, between the reference generator and the amplification circuitry, to vary the loop gain of the feedback control system as a function of the reference magnitude

  18. Tracheal stoma necrosis: a case repor

    Directory of Open Access Journals (Sweden)

    Pak S

    2017-04-01

    Full Text Available Acute tracheal dilatation, due to an overinflated cuff, has been reported early in the course of mechanical ventilation through an endotracheal tube. Tracheal stoma necrosis is a rare complication, but such can accompany acute tracheal dilation. Herein, we report a case of tracheal necrosis 9 days following tracheostomy placement in a 71-year old woman associated with overinflation of the tracheal tube cuff. This case report aims to 1 add to the scant body of knowledge about the diagnosis and management for the patients with tracheal stoma necrosis and 2 raise awareness for error-traps in interpreting diagnostic images, specifically satisfaction of search error, inattentional blindness error, and alliterative error.

  19. Prevalence of streptococcus group B in tracheal tube secretions of neonates with respiratory distress: a brief report

    Directory of Open Access Journals (Sweden)

    Khosravi N

    2013-02-01

    Full Text Available Background: Infection with group B streptococcus (GBS can present with respiratory distress, Pneumonia, meningitis and Osteomyelitis in neonates. The aim of this study was to determine the prevalence of GBS colonization in trachea of intubated neonates.Methods: This observational analytic study was performed upon 33 intubated neonates due to respiratory distress in neonatal intensive care unit (NICU Rasoul Hospital in Tehran, Iran during 2010-2012. Tracheal secretions cultured upon TODD-HEWITT BROTH and sheep blood agar 5%., chi-square test was used for compare the qualitative variables. P<0.05 was considered meaningful.Results: Three cases had positive streptococcal culture (9.1% and four cases had posi-tive culture for non-streptococcal organisms. no meaningful relation observed between positive GBS culture and neonatal gender, kind of delivery, PROM.Conclusion: Prevalence of GBS positive results (9% in present study is very close to GBS colonization in pregnant women; although the higher colonization rate of pregnant women are expected.

  20. Tracheal web

    International Nuclear Information System (INIS)

    Legasto, A.C.; Haller, J.O.; Giusti, R.J.

    2004-01-01

    Congenital tracheal web is a rare entity often misdiagnosed as refractory asthma. Clinical suspicion based on patient history, examination, and pulmonary function tests should lead to its consideration. Bronchoscopy combined with CT imaging and multiplanar reconstruction is an accepted, highly sensitive means of diagnosis. (orig.)

  1. Time to tracheal extubation after coronary artery surgery with isoflurane, sevoflurane, or target-controlled propofol anesthesia: a prospective, randomized, controlled trial.

    Science.gov (United States)

    Parker, Francis C; Story, David A; Poustie, Stephanie; Liu, Guoming; McNicol, Larry

    2004-10-01

    To determine if anesthesia with sevoflurane or target-controlled propofol reduced the time to tracheal extubation after coronary artery bypass graft surgery compared with isoflurane anesthesia. A 3-arm (isoflurane, sevoflurane, or propofol), randomized, controlled trial with patients and intensive care staff blinded to the drug allocation. A single, tertiary referral hospital affiliated with the University of Melbourne. Three hundred sixty elective coronary artery surgery patients. Patients received either isoflurane (control group, 0.5%-2% end-tidal concentration), sevoflurane (1%-4% end-tidal concentration), or target-controlled infusion of propofol (1-8 microg/mL plasma target concentration) as part of a balanced, standardized anesthetic technique including 15 microg/kg of fentanyl. The primary outcome was time to tracheal extubation. The median time to tracheal extubation for the propofol group was 10.25 hours (interquartile range [IQR] 8.08-12.75), the sevoflurane group 9.17 hours (IQR 6.25-11.25), and the isoflurane group 7.67 hours (IQR 6.25-9.42). Intraoperatively, the propofol group required less vasopressor (p = 0.002) and more vasodilator therapy (nitroglycerin p = 0.01, nitroprusside p = 0.002). There was no difference among the groups in time to intensive care unit discharge. The median time to tracheal extubation was significantly longer for the target-controlled propofol group. A significantly greater number in this group required the use of a vasodilator to control intraoperative hypertension.

  2. Laryngeal morbidity after tracheal intubation

    DEFF Research Database (Denmark)

    Sørensen, M K; Rasmussen, N; Kristensen, M S

    2013-01-01

    BACKGROUND: Tracheal intubation may cause vocal fold damage. The trial was designed to assess laryngeal morbidity comparing the Endoflex(®) tube with a conventional endotracheal tube with stylet. We hypothesised that laryngeal morbidity within the first 24 h after extubation would be lower...... with the Endoflex tube than with the conventional endotracheal tube with stylet because of less rigidity. METHODS: This randomised trial included 130 elective surgical patients scheduled for general anaesthesia with endotracheal intubation. Pre- and post-operative assessment of hoarseness, vocal fold pathology......% with the Endoflex tube and 55% with the endotracheal tube with stylet at 24 h after extubation (P = 0.44). Post-operative vocal fold injury was present in 23% in the Endoflex tube group and in 36% in the endotracheal tube with stylet group (P = 0.13). The increase in shimmer, the voice analysis variable reflecting...

  3. Control rod guide tube of nuclear reactor

    International Nuclear Information System (INIS)

    Suda, Yoshitaka; Ito, Kenji; Matsumoto, Kunio.

    1994-01-01

    Zr having a residual tensile stress of 3 to 10kg/mm 2 in a circumferential direction is used for the main ingredient of a control guide tube of a nuclear reactor. For this purpose, an appropriate correction method such as a roll-correction, tension-correction and press-correction method is applied to an existent Zr-base alloy tube with no substantial residual stress. If the residual tensile stress in the circumferential direction is smaller than 3kg/mm 2 , an effect sufficient to suppress irradiation growth is not obtainable, if it exceeds 10kg/mm 2 , dimensional changes, cracks or the like occurs locally since the wall thickness of the control rod guide tube is small and, accordingly, this often results in failed products as the control guide tube. (N.H.)

  4. Neutron generator tube ion source control

    International Nuclear Information System (INIS)

    Bridges, J.R.

    1982-01-01

    A system is claimed for controlling the output of a neutron generator tube of the deuterium-tritium accelerator type and having an ion source to produce sharply defined pulses of neutrons for well logging use. It comprises: means for inputting a relatively low voltage input control pulse having a leading edge and a trailing edge; means, responsive to the input control pulse, for producing a relatively high voltage ion source voltage pulse after receipt of the input pulse; and means, responsive to the input control pulse, for quenching, after receipt of the input pulse, the ion source control pulse, thereby providing a sharply time defined neutron output from the generator tube

  5. Low tracheal tumor and airway management: An anesthetic challenge

    Directory of Open Access Journals (Sweden)

    Richa Saroa

    2015-01-01

    Full Text Available We describe a case presenting with tracheal tumor wherein a Microlaryngeal tube was advanced into the trachea distal to the tumor for primary airway control followed by cannulation of both endobronchial lumen with 5.5 mm endotracheal tubes to provide independent lung ventilation post tracheal transection using Y- connector attached to anesthesia machine. The plan was formulated to provide maximal surgical access to the trachea while providing adequate ventilation at the same time. A 32 yrs non smoker male, complaining of cough, progressive dyspnea and hemoptysis was diagnosed to have a broad based mass in the trachea on computed tomography of chest. Bronchoscopy of the upper airway confirmed presence of the mass at a distance of 9 cms from the vocal cords, obstructing the tracheal lumen by three fourth of the diameter. The patient was scheduled to undergo the resection of the mass through anterolateral thoracotomy. We recommend the use of extralong, soft, small sized microlaryngeal surgery tube in tumors proximal to carina, for securing the airway before the transection of trachea and bilateral endobronchial intubation with small sized cuffed endotracheal tubes for maintenance of ventilation after the transection of trachea in patients with mass in the lower trachea.

  6. Non-destructive controls in the steel tube industry

    International Nuclear Information System (INIS)

    Mondot, J.

    1978-01-01

    The main non-destructive control methods in the tube industry are reviewed: eddy currents, particularly well adapted to small tubes; magnetoscopic testing for weldless tubes; ultrasonic waves widely used for thick weldless tubes and weldings; radiography, to examine tube ends and the known questionable zones; measure of diameters by laser [fr

  7. Tube Model Predictive Control with an Auxiliary Sliding Mode Controller

    Directory of Open Access Journals (Sweden)

    Miodrag Spasic

    2016-07-01

    Full Text Available This paper studies Tube Model Predictive Control (MPC with a Sliding Mode Controller (SMC as an auxiliary controller. It is shown how to calculate the tube widths under SMC control, and thus how much the constraints of the nominal MPC have to be tightened in order to achieve robust stability and constraint fulfillment. The analysis avoids the assumption of infinitely fast switching in the SMC controller.

  8. Electroacoustic control of Rijke tube instability

    Science.gov (United States)

    Zhang, Yumin; Huang, Lixi

    2017-11-01

    Unsteady heat release coupled with pressure fluctuation triggers the thermoacoustic instability which may damage a combustion chamber severely. This study demonstrates an electroacoustic control approach of suppressing the thermoacoustic instability in a Rijke tube by altering the wall boundary condition. An electrically shunted loudspeaker driver device is connected as a side-branch to the main tube via a small aperture. Tests in an impedance tube show that this device has sound absorption coefficient up to 40% under normal incidence from 100 Hz to 400 Hz, namely over two octaves. Experimental result demonstrates that such a broadband acoustic performance can effectively eliminate the Rijke-tube instability from 94 Hz to 378 Hz (when the tube length varies from 1.8 m to 0.9 m, the first mode frequency for the former is 94 Hz and the second mode frequency for the latter is 378 Hz). Theoretical investigation reveals that the devices act as a damper draining out sound energy through a tiny hole to eliminate the instability. Finally, it is also estimated based on the experimental data that small amount of sound energy is actually absorbed when the system undergoes a transition from the unstable to stable state if the contrpaol is activated. When the system is actually stabilized, no sound is radiated so no sound energy needs to be absorbed by the control device.

  9. Control rod guide tube cleaning device

    International Nuclear Information System (INIS)

    Tsuji, Tadashi; Shiota, Yoshiaki.

    1990-01-01

    Since there was no exclusive device for cleaning control rods, no effective cleaning could not be conducted and there was a possibility that obstacles may not be recovered. Then, there are disposed a first pump for supplying pressurized water, a spray nozzle for forming a swirling flow in a control rod guide tube, a second pump for pressurizing water introduced by a sucking pipeline and a collecting device for recovering obstacles intruding to water from the second pump. The pressurized water supplied from the first pump is introduced to a head passing through a blowing pipe and jetted from the spray nozzle to the control rod guide tube. In this case, a swirling stream occurs and obstacles in the control guide tube are mixed into water. The water containing the obstacles passes from the sucking port through a pipeline, introduced to the second pump and recovered to the collecting device. Since there is no water staying portion upon cleaning operation, the obstacles accumulating over the entire region of the bottom of the guide tube can be recovered reliably and efficiently. (N.H.)

  10. Efeitos da pressão limite (25 cmH2O e mínima de “selo” do balonete de tubos traqueais sobre a mucosa traqueal do cão Efectos de la presión limite (25 cmH2O y mínima de “sello” del balón de tubos traquéales sobre la mucosa traqueal del can Effects of tracheal tube cuff limit pressure (25 cmH2O and “seal” pressure on tracheal mucosa of dogs

    Directory of Open Access Journals (Sweden)

    Emanuel Celice Castilho

    2003-12-01

    ón del tubo traqueal insuflado con volumen de aire suficiente para obtener presión de “sello” o con la presión limite de 25 cmH2O, abajo de la presión crítica de 30 cm de agua para producción de lesión de la mucosa traqueal. MÉTODO: Diez y seis canes fueron sometidos a anestesia venosa y ventilación artificial. Los canes fueron distribuidos aleatoriamente en dos grupos de acuerdo con la presión en el balón del tubo traqueal (Portex Blue-Line, Inglaterra: Gsello (n = 8 balón con presión mínima de “sello” para impedir vaciamiento de aire durante la respiración artificial; G25 (n = 8 balón insuflado hasta la obtención de la presión de 25 cmH2O. La medida de la presión del balón fue realizada por medio de manómetro digital en el inicio (control y después de 60, 120 y 180 minutos. Después del sacrificio de los canes, fueron hechas biopsias en las áreas de la mucosa traqueal adyacentes al balón y al tubo traqueal para análisis de microscopio electrónico de barredura (MEV. RESULTADOS: La presión media del balón en G25 se mantuvo entre 24,8 y 25 cmH2O y en Gsello entre 11,9 y 12,5 cmH2O durante el experimento. Las alteraciones a la MEV fueron pequeñas y no significantemente diferentes en los grupos (p > 0,30, pero ocurrieron lesiones más intensas en las áreas de contacto de la mucosa traqueal con el balón del tubo traqueal, en los dos grupos, en relación a las áreas de la mucosa adyacentes o no al tubo traqueal (p BACKGROUND AND OBJECTIVES: Injuries of tracheal mucosa in contact with tracheal tube cuff is a function of cuff pressure and exposure time. This study aimed at analyzing injuries of tracheal mucosa in contact with tracheal tube cuff inflated to reach “seal” pressure or limit 25 cmH2O pressure, below critical 30 cmH2O, to prevent tracheal damage. METHODS: This study involved 16 dogs submitted to intravenous anesthesia and artificial ventilation. Dogs were randomly distributed into two experimental groups according to

  11. [Successful One-lung Ventilation with a Right-sided Double-lumen Tube in a Patient with a Right Upper Tracheal Bronchus, who Underwent Left Pneumonectomy for Left Hilar Lung Cancer].

    Science.gov (United States)

    Kawagoe, Izumi; Kohchiyama, Tsukasa; Hayashida, Masakazu; Satoh, Daizoh; Suzuki, Kenji; Inada, Eiichi

    2016-06-01

    A 60-year-old male patient with left hilar lung cancer was scheduled to undergo left pneumonectomy or left sleeve lower lobectomy. Preoperative computer tomographic and bronchoscopic examinations revealed that the bronchus (B1) to the right apical segment (S1) was a tracheal bronchus (TB) originating from the trachea approximately 10 mm above the carina. Because the left main bronchus was to be dissected, a right-sided double-lumen tube (DLT) was selected to completely protect the right lung from spillage of secretions or cancer cells from the left lung. The right-sided DLT was placed so as to fit its lateral opening of the bronchial lumen to normal upper branches (B2, B3), while sacrificing ventilation of S1 with an abnormal branch (B1). However, one-lung ventilation (OLV) of the right lung could not be achieved, since a gas leakage from the opened tracheal lumen occurred, most probably due to intra-lobar micro-airway communications between S1 and S2/S3. The DLT was withdrawn until the blue bronchial cuff occluded the orifice of the TB (B1). Although the upper half of the blue bronchial cuff appeared above the tracheal carina, OLV through the two bronchial lumen openings could be achieved due to a specific, slanted doughnut shape of the blue bronchial cuff and the location of the abnormal branch (B1) approximate to the carina. Left pneumonectomy using successful OLV was completed safely without hypoxemia or hypercapnea. Our experience indicates that management of OLV for patients with a thoracheal bronchus needs special considerations of the exact location of the TB and intra-lobar micro-airway communications, in addition to types of scheduled surgical procedures.

  12. A comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: A randomised, controlled clinical trial.

    LENUS (Irish Health Repository)

    Maharaj, C H

    2006-11-01

    The Airtraq laryngoscope is a novel single use tracheal intubation device. We compared the Airtraq with the Macintosh laryngoscope in patients deemed at low risk for difficult intubation in a randomised, controlled clinical trial. Sixty consenting patients presenting for surgery requiring tracheal intubation were randomly allocated to undergo intubation using a Macintosh (n = 30) or Airtraq (n = 30) laryngoscope. All patients were intubated by one of four anaesthetists experienced in the use of both laryngoscopes. No significant differences in demographic or airway variables were observed between the groups. All but one patient, in the Macintosh group, was successfully intubated on the first attempt. There was no difference between groups in the duration of intubation attempts. In comparison to the Macintosh laryngoscope, the Airtraq resulted in modest improvements in the intubation difficulty score, and in ease of use. Tracheal intubation with the Airtraq resulted in less alterations in heart rate. These findings demonstrate the utility of the Airtraq laryngoscope for tracheal intubation in low risk patients.

  13. Neutron generator tube ion source control apparatus

    International Nuclear Information System (INIS)

    Bridges, J.R.

    1982-01-01

    A pulsed neutron well logging system includes a neutron generator tube of the deuterium-tritium accelerator type and an ion source control apparatus providing extremely sharply time-defined neutron pulses. A low voltage control pulse supplied to an input by timing circuits turns a power FET on via a buffer-driver whereby a 2000 volt pulse is produced in the secondary of a pulse transformer and applied to the ion source of the tube. A rapid fall in this ion source control pulse is ensured by a quenching circuit wherein a one-shot responds to the falling edge of the control pulse and produces a 3 microsecond delay to compensate for the propagation delay. A second one-shot is triggered by the falling edge of the output of the first one-shot and gives an 8 microsecond pulse to turn on the power FET which, via an isolation transformer turns on a series-connected transistor to ground the secondary of the pulse transformer and the ion source. (author)

  14. CT of tracheal agenesis

    International Nuclear Information System (INIS)

    Strouse, Peter J.; Hernandez, Ramiro J.; Newman, Beverley

    2006-01-01

    Tracheal agenesis is a rare and usually lethal anomaly. In the past, opaque contrast medium was injected via the esophagus to demonstrate the anatomy. To demonstrate the utility of helical and multidetector CT in delineating the aberrant anatomy in newborns with tracheal agenesis. Four newborns with tracheal agenesis were identified from three institutions. Imaging studies and medical records were reviewed. Each child was imaged with chest radiography. One child was imaged on a single-detector helical CT scanner and the other three on multidetector scanners. Helical and multidetector CT with 2D and 3D reconstructions clearly delineated the aberrant tracheobronchial and esophageal anatomy in each infant. Minimum intensity projection reformatted CT images were particularly helpful. One infant each had type I and type II tracheal agenesis. Two infants had type III tracheal agenesis. All four infants died. CT is a useful tool for delineating the aberrant anatomy of newborns with tracheal agenesis and thus helps in making rational clinical decisions. (orig.)

  15. and Non-Operable Tracheal Stenosis

    Directory of Open Access Journals (Sweden)

    Reza Bagheri

    2013-05-01

    Full Text Available   Introduction: Tracheal stenosis is normally caused by trauma, infection, benign and malignant tumors, prolonged intubation or tracheostomy. The best treatment for tracheal stenosis is resection and anastomosis of trachea. Yet the major surgical complication of tracheal surgery is postoperative stenosis. The goal of this paper is to study the result of tracheal stenting as a replacement therapy for patients suffering from tracheal stenosis who are not good candidates for surgery.   Materials and Methods: This study presents the results of stenting in patients with: Inoperable tumoral stenosis,Non-tumoral stenosis being complicated due to prior surgeries,Inability to undergo a major surgery.The study was performed between September 2002 and July 2011 and poly flex stents were used by means of rigid bronchoscopy. Results: A total of 25 patients received stents during this study. Among them 15 patients suffered from benign and 10 suffered from malignant tracheal stenosis. The patients were followed up for at most 12 months after the stenting operation. The mean age of the patients was 35 years. The most common cause of stenosis was prolonged intubation (75%. The most common indication for stenting was the history of multiple tracheal operations. The most common complication of stenting and cause of stent removal was formation of granulation tissue. 30% of patients with benign tracheal stenosis were cured and about 10% improved until they could stand a major operation. Ten patients in benign group and 2 patients in malignant group (20% needed T-Tube insertion after stent removal but other patientcure by stenting. Conclusions: In benign cases stenting is associated with recurrence of symptoms which requires other therapeutic techniqus, so the stenting may not be named as a final solution in benign cases. However, this technique is the only method with approved efficacy for malignant cases with indication.

  16. Integrated Computer Controlled Glow Discharge Tube

    Science.gov (United States)

    Kaiser, Erik; Post-Zwicker, Andrew

    2002-11-01

    An "Interactive Plasma Display" was created for the Princeton Plasma Physics Laboratory to demonstrate the characteristics of plasma to various science education outreach programs. From high school students and teachers, to undergraduate students and visitors to the lab, the plasma device will be a key component in advancing the public's basic knowledge of plasma physics. The device is fully computer controlled using LabVIEW, a touchscreen Graphical User Interface [GUI], and a GPIB interface. Utilizing a feedback loop, the display is fully autonomous in controlling pressure, as well as in monitoring the safety aspects of the apparatus. With a digital convectron gauge continuously monitoring pressure, the computer interface analyzes the input signals, while making changes to a digital flow controller. This function works independently of the GUI, allowing the user to simply input and receive a desired pressure; quickly, easily, and intuitively. The discharge tube is a 36" x 4"id glass cylinder with 3" side port. A 3000 volt, 10mA power supply, is used to breakdown the plasma. A 300 turn solenoid was created to demonstrate the magnetic pinching of a plasma. All primary functions of the device are controlled through the GUI digital controllers. This configuration allows for operators to safely control the pressure (100mTorr-1Torr), magnetic field (0-90Gauss, 7amps, 10volts), and finally, the voltage applied across the electrodes (0-3000v, 10mA).

  17. Iatrogenic tracheal tear.

    LENUS (Irish Health Repository)

    Dias, A

    2010-10-01

    Large post intubation tracheal tears are usually detected intra-operatively due to unstable signs namely impaired ventilation and mediastinal emphysema and often require surgical management. Smaller tracheal tears are often missed during anaesthesia and recognized during the postoperative period. Conservative management should be considered in these latter cases.

  18. CO2 driven endotracheal tube cuff control in critically ill patients: A randomized controlled study.

    Science.gov (United States)

    De Pascale, Gennaro; Pennisi, Mariano Alberto; Vallecoccia, Maria Sole; Bello, Giuseppe; Maviglia, Riccardo; Montini, Luca; Di Gravio, Valentina; Cutuli, Salvatore Lucio; Conti, Giorgio; Antonelli, Massimo

    2017-01-01

    To determine the safety and clinical efficacy of an innovative integrated airway system (AnapnoGuard™ 100 system) that continuously monitors and controls the cuff pressure (Pcuff), while facilitating the aspiration of subglottic secretions (SS). This was a prospective, single centre, open-label, randomized, controlled feasibility and safety trial. The primary endpoint of the study was the rate of device related adverse events (AE) and serious AE (SAE) as a result of using AnapnoGuard (AG) 100 during mechanical ventilation. Secondary endpoints were: (1) mechanical complications rate (2) ICU staff satisfaction; (3) VAP occurrence; (4) length of mechanical ventilation; (5) length of Intensive Care Unit stay and mortality; (6) volume of evacuated subglottic secretions. Sixty patients were randomized to be intubated with the AG endotracheal-tube (ETT) and connected to the AG 100 system allowing Pcuff adjustment and SS aspiration; or with an ETT combined with SS drainage and Pcuff controlled manually. No difference in adverse events rate was identified between the groups. The use of AG system was associated with a significantly higher incidence of Pcuff determinations in the safety range (97.3% vs. 71%; paspirated SS secretions: (192.0[64-413] ml vs. 150[50-200], p = 0.19 (total)); (57.8[20-88.7] ml vs. 50[18.7-62] ml, p = 0.11 (daily)). No inter-group difference was detected using AG system vs. controls in terms of post-extubation throat pain level (0 [0-2] vs. 0 [0-3]; p = 0.7), hoarseness (42.9% vs. 75%; p = 0.55) and tracheal mucosa oedema (16.7% vs. 10%; p = 0.65). Patients enrolled in the AG group had a trend to reduced VAP risk of ventilator-associated pneumonia(VAP) (14.8% vs. 40%; p = 0.06), which were more frequently monomicrobial (25% vs. 70%; p = 0.03). No statistically significant difference was observed in duration of mechanical ventilation, ICU stay, and mortality. The use AG 100 system and AG tube in critically ill intubated patients is safe and

  19. CO2 driven endotracheal tube cuff control in critically ill patients: A randomized controlled study.

    Directory of Open Access Journals (Sweden)

    Gennaro De Pascale

    Full Text Available To determine the safety and clinical efficacy of an innovative integrated airway system (AnapnoGuard™ 100 system that continuously monitors and controls the cuff pressure (Pcuff, while facilitating the aspiration of subglottic secretions (SS.This was a prospective, single centre, open-label, randomized, controlled feasibility and safety trial. The primary endpoint of the study was the rate of device related adverse events (AE and serious AE (SAE as a result of using AnapnoGuard (AG 100 during mechanical ventilation. Secondary endpoints were: (1 mechanical complications rate (2 ICU staff satisfaction; (3 VAP occurrence; (4 length of mechanical ventilation; (5 length of Intensive Care Unit stay and mortality; (6 volume of evacuated subglottic secretions. Sixty patients were randomized to be intubated with the AG endotracheal-tube (ETT and connected to the AG 100 system allowing Pcuff adjustment and SS aspiration; or with an ETT combined with SS drainage and Pcuff controlled manually.No difference in adverse events rate was identified between the groups. The use of AG system was associated with a significantly higher incidence of Pcuff determinations in the safety range (97.3% vs. 71%; p<0.01 and a trend to a greater volume of aspirated SS secretions: (192.0[64-413] ml vs. 150[50-200], p = 0.19 (total; (57.8[20-88.7] ml vs. 50[18.7-62] ml, p = 0.11 (daily. No inter-group difference was detected using AG system vs. controls in terms of post-extubation throat pain level (0 [0-2] vs. 0 [0-3]; p = 0.7, hoarseness (42.9% vs. 75%; p = 0.55 and tracheal mucosa oedema (16.7% vs. 10%; p = 0.65. Patients enrolled in the AG group had a trend to reduced VAP risk of ventilator-associated pneumonia(VAP (14.8% vs. 40%; p = 0.06, which were more frequently monomicrobial (25% vs. 70%; p = 0.03. No statistically significant difference was observed in duration of mechanical ventilation, ICU stay, and mortality.The use AG 100 system and AG tube in critically ill

  20. Endoscopically placed nitinol stents for pediatric tracheal obstruction.

    Science.gov (United States)

    Prasad, Mukesh; Bent, John P; Ward, Robert F; April, Max M

    2002-11-11

    To provide preliminary clinical data regarding endoscopically placed nitinol stents for children with tracheal obstruction as a temporizing measure to allow for trach tube decannulation while awaiting growth to allow for tracheal resection. This case series describes the experiences of two children (ages 5 and 15) who were dependent upon tracheotomy because of acquired tracheal obstruction. Both patients had combined tracheomalacia and tracheal stenosis. After failing tracheoplasty with rib graft augmentation both patients suffered from extensive tracheal disease, which was too long to allow for immediate tracheal resection. Endoscopic placement of nitinol stents in the obstructed tracheal segment using fluoroscopic guidance. All tracheotomy tubes were removed immediately after successful stent deployment with the patient still under general anesthesia. Four stents were placed in total. The first patient's initial stent was too narrow and was, therefore, removed and replaced at a later date with a larger diameter stent. The second patient experienced distal migration of his initial stent requiring stent removal and replacement at a later date. Both patients remain successfully decannulated (follow-up, 25 and 26 months) and are currently living more normal lives as they grow and await tracheal resection. Preliminary use of nitinol stents for pediatric tracheal obstruction has enabled successful decannulation in two children with complicated airways. Our results with this series of patients suggest that nitinol stents can be safely used in children as a temporizing measure until tracheal resection can be safely performed. With this approach children can live free from the hassles of trach care, social isolation and peer ridicule. Limited pediatric experience exists in the literature about nitinol stents. Thus, our experience with stent selection and placement will help others avoid problems encountered in this initial series. Copyright 2002 Elsevier Science Ireland

  1. Comparison of Ambu® AuraGain™ laryngeal mask and air-Q™ intubating laryngeal airway for blind tracheal intubation in adults: A randomized controlled trial

    OpenAIRE

    Sameer Sethi; Souvik Maitra; Vikas Saini; Tanvir Samara

    2017-01-01

    Background: This study has been designed to compare the performance of Ambu® AuraGain™ laryngeal mask with the air-Q™ as a conduit for blind tracheal intubation in adult patients. Methods: In this prospective randomized controlled trial blind endotracheal intubation success rates were compared between Ambu® AuraGain™ and air-Q™ intubating laryngeal airway in 90 adult patients. Patients were randomized in two equal groups: Group Ambu® AuraGain™ (n = 45) and Group air-Q™ (n = 45). Results...

  2. EFFECT OF INTRACUFF MEDIA-ALKALINISED LIGNOCAINE, SALINE, AND AIR ON ENDOTRACHEAL TUBE INDUCED EMERGENCE PHENOMENA: A RANDOMIZED CONTROLLED STUDY

    Directory of Open Access Journals (Sweden)

    Indu S

    2016-07-01

    Full Text Available CONTEXT Emergence from general anaesthesia is associated with post extubation cough, hoarseness, sore throat, and dysphagia, which may affect the smoothness of extubation. Prophylactic interventions have been studied to reduce these tracheal morbidities with varying results. AIMS To compare the efficacy of air, alkalinised lignocaine and saline in maintaining intracuff pressure and reducing postoperative cough (PEC and sore throat (POST. SETTINGS AND DESIGN A randomised controlled study conducted in a teaching hospital. METHODS AND MATERIALS 105 patients scheduled for elective surgeries were randomly allocated into groups of 35 each. The endotracheal tube (ETT cuffs were inflated with air, alkalinised lignocaine, or saline. The intracuff pressure (ICP was initially set to 25-30 cm of H2O; measured every 30 minutes and before extubation; the minimum volume for occlusion (MOV noted. The incidence PEC and POST were monitored. STATISTICAL ANALYSIS Data analysed using Chi-square test, Fisher’s exact test; Bonferroni method allowed multiple comparisons. A p value <0.05 was considered significant. RESULTS Pre-lubricated ETT cuff inflation with liquid media maintained an acceptable ICP. Saline and alkalinised lignocaine were effective in reducing PEC and POST. Alkalinised lignocaine provided smoother extubation and fared better in the early postoperative period. CONCLUSIONS Pre-lubricated ETT cuffs with liquid media reduced PEC and POST. Alkalinised lignocaine showed better profile than saline. Optimum ICP reduces tracheal morbidity.

  3. Research on temperature control and influence of the vacuum tubes with inserted tubes solar heater

    Science.gov (United States)

    Xiao, L. X.; He, Y. T.; Hua, J. Q.

    2017-11-01

    A novel snake-shape vacuum tube with inserted tubes solar collector is designed in this paper, the heat transfer characteristics of the collector are analyzed according to its structural characteristics, and the influence of different working temperature on thermal characteristics of the collector is studied. The solar water heater prototype consisting of 14 vacuum tubes with inserted tubes is prepared, and the hot water storage control subsystem is designed by hysteresis comparison algorithm. The heat characteristic of the prototype was experimentally studied under hot water output temperature of 40-45°C, 50-55°C and 60-65°C. The daily thermal efficiency was 64%, 50% and 46%, respectively. The experimental results are basically consistent with the theoretical analysis.

  4. Modeling, Prediction, and Control of Heating Temperature for Tube Billet

    Directory of Open Access Journals (Sweden)

    Yachun Mao

    2015-01-01

    Full Text Available Annular furnaces have multivariate, nonlinear, large time lag, and cross coupling characteristics. The prediction and control of the exit temperature of a tube billet are important but difficult. We establish a prediction model for the final temperature of a tube billet through OS-ELM-DRPLS method. We address the complex production characteristics, integrate the advantages of PLS and ELM algorithms in establishing linear and nonlinear models, and consider model update and data lag. Based on the proposed model, we design a prediction control algorithm for tube billet temperature. The algorithm is validated using the practical production data of Baosteel Co., Ltd. Results show that the model achieves the precision required in industrial applications. The temperature of the tube billet can be controlled within the required temperature range through compensation control method.

  5. Application of internal electrodes to the oesophageal and tracheal tube in an animal trial: evaluation of its clinical and technical potentiality in electrical impedance tomography.

    Science.gov (United States)

    Czaplik, Michael; Antink, Christoph Hoog; Rossaint, Rolf; Leonhardt, Steffen

    2014-06-01

    Electrical impedance tomography (EIT) is of potential medical interest e.g., to optimize ventilator settings during mechanical ventilation. Nevertheless there are still several challenges. Although electrode belts are commonly used and promoted, they are not necessarily adequate for the long-term monitoring of patients in intensive-care units (ICU). ICU patients are usually equipped with breathing tubes and feeding tubes, ideal surfaces to attach EIT electrodes to. The aim of our study was therefore to examine the potentiality of internal electrodes in a porcine animal trial. Following an animal trial protocol studying acute lung injury, additional EIT measurements were obtained both with conventional electrodes set upon a rubber belt and after having moved the electrodes internally in seven pigs. For this reason the two most dorsally located electrodes were selected. An adjacent stimulation and measurement pattern was used, and resulting voltages in the time and frequency domains as well as within reconstructed images were examined to compare perfusion and ventilation data qualitatively and quantitatively. Particularly, lung morphology as well as signal strength for both the mediastinal and lung region were studied. All animals were submitted to the additional protocol without any adverse events. Distinguishability of lungs was improved in reconstructed frames. The resulting sensitivity of measured electrical impedance was enhanced around the mediastinal region and even cardiac-related activity was significantly increased by a factor of up to 6. In conclusion the application of internal electrodes appears to be beneficial for diverse clinical purposes and should be addressed in further studies.

  6. Tracheal collapse in two cats

    International Nuclear Information System (INIS)

    Hendricks, J.C.; O'Brien, J.A.

    1985-01-01

    Two cats examined bronchoscopically to discover the cause of tracheal collapse were found to have tracheal obstruction cranial to the collapse. Cats with this unusual sign should be examined bronchoscopically to ascertain whether there is an obstruction, as the cause in these 2 cats was distinct from the diffuse airway abnormality that causes tracheal collapse in dogs

  7. Primary tracheal adenocystic carcinoma and tracheal tumors during pregnancy

    Directory of Open Access Journals (Sweden)

    Cem Gundogdu

    2011-07-01

    Full Text Available Cancer complicates approximately 0.1% of all pregnancies. Primary tracheal carcinoma is one of very rarely seen tumors and the rate of its being seen makes up approximately % 0,2 of all tumors of respiratory tract. The patient, 28 years old, who has 28-weeks-pregnant, was diagnosed with primary tracheal adenocystic carcinoma. Patient was made operation as thoracotomy and tracheal tumor was removed at the 28th week of pregnancy. Patient was delivered with sectio abdominale at the 39th week of pregnancy. Primary tracheal adenocystic carcinoma is very rarely seen tumors and it is the first tracheal ACC with pregnancy case in literature to have been detected and surgically treated during pregnancy. We discussed primary tracheal adenocystic carcinoma and tracheal tumors during pregnancy with literature.

  8. Sporophytic control of pollen tube growth and guidance in maize

    Science.gov (United States)

    Lausser, Andreas; Kliwer, Irina; Srilunchang, Kanok-orn; Dresselhaus, Thomas

    2010-01-01

    Pollen tube germination, growth, and guidance (progamic phase) culminating in sperm discharge is a multi-stage process including complex interactions between the male gametophyte as well as sporophytic tissues and the female gametophyte (embryo sac), respectively. Inter- and intra-specific crossing barriers in maize and Tripsacum have been studied and a precise description of progamic pollen tube development in maize is reported here. It was found that pollen germination and initial tube growth are rather unspecific, but an early, first crossing barrier was detected before arrival at the transmitting tract. Pollination of maize silks with Tripsacum pollen and incompatible pollination of Ga1s/Ga1s-maize silks with ga1-maize pollen revealed another two incompatibility barriers, namely transmitting tract mistargeting and insufficient growth support. Attraction and growth support by the transmitting tract seem to play key roles for progamic pollen tube growth. After leaving transmitting tracts, pollen tubes have to navigate across the ovule in the ovular cavity. Pollination of an embryo sac-less maize RNAi-line allowed the role of the female gametophyte for pollen tube guidance to be determined in maize. It was found that female gametophyte controlled guidance is restricted to a small region around the micropyle, approximately 50–100 μm in diameter. This area is comparable to the area of influence of previously described ZmEA1-based short-range female gametophyte signalling. In conclusion, the progamic phase is almost completely under sporophytic control in maize. PMID:19926683

  9. Corrugated thimble tube for controlling control rod descent in nuclear reactor

    International Nuclear Information System (INIS)

    Luetzow, H.J.

    1981-01-01

    A thimble tube construction is described which will provide a controlled descent for a control rod while minimizing the reaction forces which must be absorbed by the thimble tube and reducing the possibility that a foreign particle could interfere with the free descent of a control rod. A thimble tube is formed with helically-corrugate internal walls which cooperate with a control rod contained in the tube in an emergency situation to provide a progressively-increasing hydraulic restraining force as each adjacent corrugation is encountered

  10. Circumferential tracheal resection with primary anastomosis for post-intubation tracheal stenosis: study of 24 cases.

    Science.gov (United States)

    Negm, Hesham; Mosleh, Mohamed; Fathy, Hesham

    2013-09-01

    The objective of this study is to evaluate the results of circumferential tracheal and cricotracheal resection with primary anastomosis for the treatment of post-intubation tracheal and cricotracheal stenosis. This is a retrospective analytical study. A total number of 24 patients were included in this study. The relevant preoperative, operative and postoperative records were collected and analyzed. Twenty patients were finally symptom-free reflecting an anastomosis success rate of 83.3 %. Variable grades of anastomotic restenosis occurred in 11 (45.8 %) patients, three patients were symptom-free and eight had airway obstructive symptoms. Four out of the eight patients with symptomatic restenosis were symptom-free with endoscopic dilatation while the remaining four patients required a permanent airway appliance (T-tube, tracheostomy) for the relief of airway obstruction and this group was considered as anastomotic failure. Cricoid involvement, associated cricoid resection and the type of anastomosis were the variables that had statistical impact on the occurrence of restenosis (P = 0.017, 0.017, 0.05; respectively). Tracheal resection with primary anastomosis is a safe effective treatment method for post-intubation tracheal stenosis in carefully selected patients. Restenosis does not always mean failure of the procedure since it may be successfully managed with endoscopic dilatation.

  11. Control of Cell Wall Extensibility during Pollen Tube Growth

    OpenAIRE

    Hepler, Peter K.; Rounds, Caleb M.; Winship, Lawrence J.

    2013-01-01

    Tip-growing pollen tubes achieve rapid elongation while maintaining cell wall integrity by balancing local expansion, controlled by local changes in wall viscosity, against exocytosis, influenced by the activity of the actin cytoskeleton, cellular energetics, and calcium and proton physiology.

  12. Humidity Control System In The Neutron Detector Of Guide Tube

    International Nuclear Information System (INIS)

    Alibasya Harahap, Sentot

    2001-01-01

    The probable symptom neutron detector damage as cause decrease resistivity and corrosion in the electrical terminal, further more occasion to voltage failure and leak current in the isolation. The prevent of voltage failure in detector a needed humidity controller's with dry air supply to guide tube with 2 kg/cm exp.2 air pressure and 7 l/min, air flow as soon as continuity dryer process in the guide tube. Reactor shutdown and operation condition of diffusion rate is 0,476 cm exp.3/year and 6,46 cm exp.3/year

  13. Saline instillation before tracheal suctioning decreases the incidence of ventilator-associated pneumonia.

    Science.gov (United States)

    Caruso, Pedro; Denari, Silvia; Ruiz, Soraia A L; Demarzo, Sergio E; Deheinzelin, Daniel

    2009-01-01

    To compare the incidence of ventilator-associated pneumonia (VAP) with or without isotonic saline instillation before tracheal suctioning. As a secondary objective, we compared the incidence of endotracheal tube occlusion and atelectasis. Randomized clinical trial. The study was conducted in a medical surgical intensive care unit of an oncologic hospital. We selected consecutive patients needing mechanical ventilation for >72 hrs. Patients were allocated into two groups: a saline group that received instillation of 8 mL of saline before tracheal suctioning and a control group which did not. VAP was diagnosed based on clinical suspicion and confirmed by bronchoalveolar lavage quantitative culture. The incidence of atelectasis on daily chest radiography and endotracheal tube occlusions were recorded. The sample size was calculated to a power of 80% and a type I error probability of 5%. One hundred thirty patients were assigned to the saline group and 132 to the control group. The baseline demographic variables were similar between groups. The rate of clinically suspected VAP was similar in both groups. The incidence of microbiological proven VAP was significantly lower in the saline group (23.5% x 10.8%; p = 0.008) (incidence density/1.000 days of ventilation 21.22 x 9.62; p < 0.01). Using the Kaplan-Meier curve analysis, the proportion of patients remaining without VAP was higher in the saline group (p = 0.02, log-rank test). The relative risk reduction of VAP in the saline instillation group was 54% (95% confidence interval, 18%-74%) and the number needed to treat was eight (95% confidence interval, 5-27). The incidence of atelectases and endotracheal tube occlusion were similar between groups. Instillation of isotonic saline before tracheal suctioning decreases the incidence of microbiological proven VAP.

  14. The Role of Tracheal Stenting As an Alternative Treatment in Cicatricial and Non-Operable Tracheal Stenosis

    Directory of Open Access Journals (Sweden)

    Reza Bagheri

    2013-05-01

    Full Text Available Introduction: Tracheal stenosis is normally caused by trauma, infection, benign and malignant tumors, prolonged intubation or tracheostomy. The best treatment for tracheal stenosis is resection and anastomosis of trachea. Yet the major surgical complication of tracheal surgery is postoperative stenosis. The goal of this paper is to study the result of tracheal stenting as a replacement therapy for patients suffering from tracheal stenosis who are not good candidates for surgery. Materials and Methods: This study presents the results of stenting in patients with: Inoperable tumoral stenosis,Non-tumoral stenosis being complicated due to prior surgeries,Inability to undergo a major surgery.The study was performed between September 2002 and July 2011 and poly flex stents were used by means of rigid bronchoscopy. Results: A total of 25 patients received stents during this study. Among them 15 patients suffered from benign and 10 suffered from malignant tracheal stenosis. The patients were followed up for at most 12 months after the stenting operation. The mean age of the patients was 35 years. The most common cause of stenosis was prolonged intubation (75%. The most common indication for stenting was the history of multiple tracheal operations. The most common complication of stenting and cause of stent removal was formation of granulation tissue. 30% of patients with benign tracheal stenosis were cured and about 10% improved until they could stand a major operation. Ten patients in benign group and 2 patients in malignant group (20% needed T-Tube insertion after stent removal but other patientcure by stenting. Conclusions: In benign cases stenting is associated with recurrence of symptoms which requires other therapeutic techniqus, so the stenting may not be named as a final solution in benign cases. However, this technique is the only method with approved efficacy for malignant cases with indication.

  15. Intubação traqueal Tracheal intubation

    Directory of Open Access Journals (Sweden)

    Toshio Matsumoto

    2007-05-01

    keywords intubation, tracheal intubation, child, rapid sequence intubation and pediatric airway. SUMMARY OF THE FINDINGS: Airway management in children is related to their physiology and anatomy, in addition to specific factors (inherent pathological conditions, such as malformations or acquired conditions which have a decisive influence on success. Principal indications are in order to maintain the airway patent and to control ventilation. Laryngoscopy and tracheal intubation cause cardiovascular alterations and affect airway reactivity. The use of tubes with cuffs is not prohibited, as long as the correct size for the child is chosen. A difficult airway can be identified against the Mallampati scale and by direct laryngoscopy. Rapid sequence intubation is being recommended more and more often in pediatrics, since it facilitates the procedure and presents fewer complications. Tracheal intubation should be carried out in an adequate manner in special circumstances (eaten recently, neurological dysfunction, unstable spinal column, upper airway obstruction, laryngotracheal injuries, injuries to the eyeball. Extubation should be meticulously planned, since there is chance of failure and a need for reintubation. CONCLUSIONS: Tracheal intubation of children requires knowledge, skill and experience, since, if the procedure is carried out by inexperienced pediatricians, it can result in life-threatening complications.

  16. Method of reactivity control in pressure tube reactor

    International Nuclear Information System (INIS)

    Fukumura, Nobuo.

    1988-01-01

    Purpose: To provide a method of controlling reactivity in a pressure tube reactor at high conversion ratio intended for high burn-up degree. Method: Control tubes are inserted in heavy water moderator. Light water is filled in the tubes at the initial burning stage. Along with the advance of the burning, the light water is gradually removed and replaced with gases of less reactive nuclear reactivity with neutrons such as air or gaseous carbon dioxide. The tubes are made of less neutron absorbing material such as aluminum. By filling light water, infinite multiplication factor is reduced to suppress the reactivity at the initial burning stage. As light water is gradually removed and replaced with air, etc., it provides an effect like that elimination of heavy water moderator to increase the conversion ratio. Accordingly, nuclear fission materials are produced additionally by so much to extend the burn-up degree. In this way, it can provide excellent effect in realizing high burn-up ratio and high conversion ratio. (Kamimura, M.)

  17. Cryopreserved irradiated tracheal homograft reconstruction for subglottic-tracheal stenosis

    International Nuclear Information System (INIS)

    Somyos Kunachak; Yongyudh Vajaradul; Boonchu Kulapaditharom

    1999-01-01

    Subglottic-tracheal stenosis is a common clinical entity. Handling on severe case is often problematic. Various tracheal replacement techniques have been used with varying degree of success and dispute. In this study we worked on cryopreserved irradiated tracheal homograft, of which its use in human has not been reported. The tracheas were harvested from donor cadavers within 24 hours of death in a sterile condition. After 1-2 weeks of preservation at -70 degree C, the grafts were irradiated at 25 kGy, then stored at -70 degree C until used. Four patients, 2 males and 2 females (aged 2-40 years, mean 16 years) with severe subglottic-tracheal stenosis underwent segmental tracheal graft reconstruction using this graft. Immunosuppressant was not given in any patient. The follow up period ranged from 11-1 5 months. Three patients were successfully decapulated, 1 patient developed local infection and dislodgement of intraluminal stent with subsequent restenosis. Postoperative tracheal lumen appeared near normal with histologic evidence of normal respiratory epithelium at the grafted site. In conclusion, cryopreserved irradiated tracheal homograft is a valuable alternative for tracheal transplant or reconstruction, without the need of immunosuppression

  18. Robust Output Model Predictive Control of an Unstable Rijke Tube

    Directory of Open Access Journals (Sweden)

    Fabian Jarmolowitz

    2012-01-01

    Full Text Available This work investigates the active control of an unstable Rijke tube using robust output model predictive control (RMPC. As internal model a polytopic linear system with constraints is assumed to account for uncertainties. For guaranteed stability, a linear state feedback controller is designed using linear matrix inequalities and used within a feedback formulation of the model predictive controller. For state estimation a robust gain-scheduled observer is developed. It is shown that the proposed RMPC ensures robust stability under constraints over the considered operating range.

  19. Tracheal growth after resection and anastomosis in puppies.

    Science.gov (United States)

    Blanchard, H; Brochu, P; Bensoussan, A L; Lagacé, G; Khan, A H

    1986-09-01

    Tracheal morphology, morphometric changes, and growth and histologic changes were studied in puppies submitted to tracheal resection and anastomosis. Fifteen mongrel puppies about 12 weeks old and weighing on an average 5.5 kg were operated under general anesthesia using fluothane. A median cervicotomy incision was made in ten puppies (experimental group, EG) and the proximal 14 tracheal rings were resected (average length 5.08 cm or about 35% to 38% of total tracheal length). One layer anastomosis was done using vicryl 4.0 maintaining the average tension of 1,450 g. Five puppies (control group, CG) were submitted to tracheal transection and anastomosis and the following parameters were studied. Tracheal morphology the trachea of the EG was a rounded triangle whereas in the CG it was oval in shape, there was increase in the intercartilageneous spaces in the EG, no granulation tissue was present, two mucous webs were seen in the EG and one in the CG. Morphometric changes average tracheal length EG 13 cm, CG 17.7 cm, intercartilagenous space EG 3.08 mm, CG 1.3 mm, intercricothyroid space EG 1.2 cm, CG 0.53 cm, sagittal and transverse tracheal thickness at the anastomosis EG 2.6 and 3.3 mm, CG 2 and 1.5 mm, sagittal and transverse diameter reduced on an average 2 mm in EG. Histology Moderate fibrosis was found at the level of anastomosis with no modification of chondrocytes at the cartilagenous rings in the EG. Even with high anastomotic tension, the dogs had normal tracheal growth without stenosis; the sagittal and transverse growth at the anastomosis in the EG was 90% and 85%, respectively, when compared with the CG.

  20. [The source and factors that influence tracheal pulse oximetry signal].

    Science.gov (United States)

    Fan, Xiao-hua; Wei, Wei; Wang, Jian; Mu, Ling; Wang, Li

    2010-03-01

    To investigate the source and factors that influence tracheal pulse oximetry signal. The adult mongrel dog was intubated after anesthesia. The tracheal tube was modified by attaching a disposable pediatric pulse oximeter to the cuff. The chest of the dog was cut open and a red light from the tracheal oximeter was aligned with the deeper artery. The changes in tracheal pulse oxygen saturation (SptO2) signal were observed after the deeper artery was blocked temporarily. The photoplethysmography (PPG) and readings were recorded at different intracuff pressures. The influence of mechanical ventilation on the signal was also tested and compared with pulse oxygen saturation (SpO2). The SptO2 signal disappeared after deeper artery was blocked. The SptO2 signal changed with different intracuff pressures (P signal appeared under 20-60 cm H2O of intracuff pressure than under 0-10 cm H2O of intracuff pressure(P signal under a condition with mechanical ventilation differed from that without mechanical ventilation (P signal is primarily derived from deeper arteries around the trachea, not from the tracheal wall. Both intracuff pressures and mechanical ventilation can influence SptO2 signal. The SptO2 signal under 20-60 cm H2O of intracuff pressure is stronger than that under 0-10 em H2O of intracuff pressure. Mechanical ventilation mainly changes PPG.

  1. Low-Dose or High-Dose Rocuronium Reversed with Neostigmine or Sugammadex for Cesarean Delivery Anesthesia: A Randomized Controlled Noninferiority Trial of Time to Tracheal Intubation and Extubation.

    Science.gov (United States)

    Stourac, Petr; Adamus, Milan; Seidlova, Dagmar; Pavlik, Tomas; Janku, Petr; Krikava, Ivo; Mrozek, Zdenek; Prochazka, Martin; Klucka, Jozef; Stoudek, Roman; Bartikova, Ivana; Kosinova, Martina; Harazim, Hana; Robotkova, Hana; Hejduk, Karel; Hodicka, Zuzana; Kirchnerova, Martina; Francakova, Jana; Obare Pyszkova, Lenka; Hlozkova, Jarmila; Sevcik, Pavel

    2016-05-01

    Rocuronium for cesarean delivery under general anesthesia is an alternative to succinylcholine for rapid-sequence induction of anesthesia because of the availability of sugammadex for reversal of neuromuscular blockade. However, there are no large well-controlled studies in women undergoing general anesthesia for cesarean delivery. The aim of this noninferiority trial was to determine whether rocuronium and sugammadex confer benefit in time to tracheal intubation (primary outcome) and other neuromuscular blockade outcomes compared with succinylcholine, rocuronium, and neostigmine in women undergoing general anesthesia for cesarean delivery. We aimed to enroll all women undergoing general anesthesia for cesarean delivery in the 2 participating university hospitals (Brno, Olomouc, Czech Republic) in this single-blinded, randomized, controlled study. Women were randomly assigned to the ROC group (muscle relaxation induced with rocuronium 1 mg/kg and reversed with sugammadex 2-4 mg/kg) or the SUX group (succinylcholine 1 mg/kg for induction, rocuronium 0.3 mg/kg for maintenance, and neostigmine 0.03 mg/kg for reversal of the neuromuscular blockade). The interval from the end of propofol administration to tracheal intubation was the primary end point with a noninferiority margin of 20 seconds. We recorded intubating conditions (modified Viby-Mogensen score), neonatal outcome (Apgar score rocuronium for rapid-sequence induction is noninferior for time to tracheal intubation and is accompanied by more frequent absence of laryngoscopy resistance and lower incidence of myalgia in comparison with succinylcholine for cesarean delivery under general anesthesia.

  2. [Tracheal Intubation by Paramedics in a Local Community: Current Situation and Future Challenges].

    Science.gov (United States)

    Takinami, Yoshikazu

    2016-03-01

    As of April 2013, 164 paramedics are certified to perform tracheal intubation in Fukui Prefecture. This study investigated the current situation surrounding tracheal intubation performed by paramedics in prehospital care. Subjects were 58 paramedics who completed practical training at our hospital. Post-training duration, number of tracheal intubation cases, number of attempts before successful tracheal intubation, disease involved, rate of return of spontaneous circulation, and prognosis were examined. Tracheal intubation was successful on the first attempt in 92% of cases. Rate of return of spontaneous circulation was high in paramedics whose post-training duration was short. No return of spontaneous circulation occurred after a second attempt. Four patients survived asphyxia or aspiration. It is important to perform successful tracheal intubation on the first attempt, to recognize the probability of successful resuscitation in patients with exogenous disease, and to strengthen the medical control system.

  3. Randomized controlled trial comparing nasal intermittent positive pressure ventilation and nasal continuous positive airway pressure in premature infants after tracheal extubation

    Directory of Open Access Journals (Sweden)

    Daniela Franco Rizzo Komatsu

    Full Text Available Summary Objective: To analyze the frequency of extubation failure in premature infants using conventional mechanical ventilation (MV after extubation in groups subjected to nasal intermittent positive pressure ventilation (nIPPV and continuous positive airway pressure (nCPAP. Method: Seventy-two premature infants with respiratory failure were studied, with a gestational age (GA ≤ 36 weeks and birth weight (BW > 750 g, who required tracheal intubation and mechanical ventilation. The study was controlled and randomized in order to ensure that the members of the groups used in the research were chosen at random. Randomization was performed at the time of extubation using sealed envelopes. Extubation failure was defined as the need for re-intubation and mechanical ventilation during the first 72 hours after extubation. Results: Among the 36 premature infants randomized to nIPPV, six (16.6% presented extubation failure in comparison to 11 (30.5% of the 36 premature infants randomized to nCPAP. There was no statistical difference between the two study groups regarding BW, GA, classification of the premature infant, and MV time. The main cause of extubation failure was the occurrence of apnea. Gastrointestinal and neurological complications did not occur in the premature infants participating in the study. Conclusion: We found that, despite the extubation failure of the group of premature infants submitted to nIPPV being numerically smaller than in premature infants submitted to nCPAP, there was no statistically significant difference between the two modes of ventilatory support after extubation.

  4. Effectiveness of bait tubes for brown treesnake control on Guam

    Science.gov (United States)

    Lardner, B.; Savidge, J.A.; Rodda, G.H.; Reed, R.N.; Yackel Adams, A.A.; Clark, C.S.

    2011-01-01

    A bait tube is a device with which a toxicant inserted in a dead mouse (Mus musculus) can be delivered to invasive brown treesnakes (Boiga irregularis) with low risk of non-target bait take. We tested two bait tube designs in a 5ha snake enclosure where the identity of virtually every snake is known. Instead of using toxicants, we implanted radio transmitters in small (6.6±1.4 g) and large (21.8±2.9 g) bait mice. Knowing all snakes present in the population allowed us to characterize not only covariates of snakes taking bait, but also those of snakes evading our mock control effort, and if snake covariates interacted with any design variable in determining targeting rate. Tube design had no effect on take rate. Snake snout-vent length was a strong predictor of success: none of the 29 snakes smaller than 843 mm took any bait, while the 126 snakes ≥843 mm were responsible for a total of 164 bait takes. The smallest of these snakes were able to ingest small and large mice, but tended to consume small bait at a higher rate than large bait. The main reason for our failure to target smallest snakes appears not to be gape limitation, but rather that small snakes prefer other prey (lizards). The time it takes a snake to grow from the size threshold observed to the size of maturation has implications for the interval between discrete efforts using toxic bait. Targeting all snakes before reproduction can occur is highly desirable; otherwise, a new cohort of refractory snakes may enter the population.

  5. A bispectral index guided comparison of target-controlled versus manually-controlled infusion of propofol and remifentanil for attenuation of pressor response to laryngoscopy and tracheal intubation in non cardiac surgery

    Directory of Open Access Journals (Sweden)

    Naser Yeganeh

    2006-12-01

    Full Text Available BACKGROUND: Target-controlled infusion is a new delivery system for intravenous anesthetic agents with which the anesthetist targets a plasma or effect-site drug concentration to achieve a predetermined effect. With this system, the tedious task of calculating the amount of administered drug required to achieve the target concentration is left in charge of a microprocessor which commands the infusion device. In this prospective study we compared alterations in blood pressure and heart rate from initiation of induction of anesthesia until 3 minutes after tracheal intubation in two methods of drug infusion, target-controlled infusion (TCI and manually controlled infusion (MCI. Total anesthetic drug used until 3 minutes after intubation and level of produced hypnosis also were compared between two methods. METHODS: 40 patients were enrolled in this clinical trial study and were allocated randomly in two groups, each group consisting of 20 patients. In TCI group, patients received propofol and remifentanil with TCI pump to achieve 7 µg/ml and 4 ng/ml as plasmatic target drug levels, respectively. In MCI group, patients received propofol 2 mg/kg and remifentanil 1 µg/kg of body weight with manually controlled infusion. Both groups received succinylcholine as muscle relaxant to facilitate laryngoscopy and tracheal intubation. Bispectral index (BIS was passively recorded in two groups to compare the level of hypnosis. Blood pressure (BP and heart rate (HR were recorded at 5 different times (T-1, T0, T1, T2 and T3. Independent t-test and paired t-test were used for data analysis. RESULTS: Systolic arterial pressure (SAP was not different at T-1 between two groups but systolic hypotension was seen in MCI group more than TCI group at T0 (P<0.05. Systolic hypertension was more common in MCI group after intubation; i.e. SAP showed significant differences in T1, T2 and T3 between two groups (P<0.05. Mean arterial pressure (MAP showed significant

  6. Computational fluid dynamics model of avian tracheal temperature control as a model for extant and extinct animals.

    Science.gov (United States)

    Sverdlova, N S; Arkali, F; Witzel, U; Perry, S F

    2013-10-01

    Respiratory evaporative cooling is an important mechanism of temperature control in bird. A computational simulation of the breathing cycle, heat and water loss in anatomical avian trachea/air sac model has not previously been conducted. We report a first attempt to simulate a breathing cycle in a three-dimensional model of avian trachea and air sacs (domestic fowl) using transient computational fluid dynamics. The airflow in the trachea of the model is evoked by changing the volume of the air sacs based on the measured tidal volume and inspiratory/expiratory times for the domestic fowl. We compare flow parameters and heat transfer results with in vivo data and with our previously reported results for a two-dimensional model. The total respiratory heat loss corresponds to about 13-19% of the starvation metabolic rate of domestic fowl. The present study can lend insight into a possible thermoregulatory function in species with long necks and/or a very long trachea, as found in swans and birds of paradise. Assuming the structure of the sauropod dinosaur respiratory system was close to avian, the simulation of the respiratory temperature control (using convective and evaporative cooling) in the extensively experimentally studied domestic fowl may also help in making simulations of respiratory heat control in these extinct animals. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Management of tracheal chondrosarcoma almost completely obstructing the airway: a case report.

    Science.gov (United States)

    Andolfi, Marco; Vaccarili, Maurizio; Crisci, Roberto; Puma, Francesco

    2016-07-11

    Primary malignant tracheal tumors account for only 0.2 % of all malignancies of the respiratory tract. Tracheal chondrosarcoma is a rare condition and only 17 cases have been described in the literature from 1965 to date. Herein we report the very unusual case of a patient with a tracheal chondrosarcoma, electively treated by curative surgery despite the virtually complete obstruction of the airway. We present the case of a 79-year old Caucasian man with long-lasting wheezing misdiagnosed as asthma and affected by a tracheal chondrosarcoma almost completely obstructing the airway. Videobronchoscopy and imaging investigations revealed a well-circumscribed mass arising from the cartilaginous rings of the cervical trachea with a posterior residual respiratory space of about 1 mm. Because of the mobility and flaccidity of the uninvolved pars membranacea, the tiny respiratory space slightly expanded during inspiration and expiration allowing the patient to be treated without an essential emergency procedure. Standard tracheal intubation was impossible. Rigid bronchoscopy enabled placement of a small tracheal tube distally to the tumor. Successful cervical tracheal resection and reconstruction was then performed, achieving complete tumor excision. Histologically, the mass was characterized as a low-grade tracheal chondrosarcoma. Videobronchoscopy performed 9 months after surgery showed a wide, well healed tracheal anastomosis. Ten months after surgery, the patient is alive and disease free. Complete surgical resection is the treatment of choice for tracheal chondrosarcoma. Rigid bronchoscopy is an essential tool for diagnostic and therapeutic purposes. It allows the palliative maneuvers for obstruction relief but also, in resectable patients, the intraoperative safe and straightforward management of the obstructed airway.

  8. Snake Envenomation Causing Distant Tracheal Myonecrosis

    Directory of Open Access Journals (Sweden)

    Amina Khimani

    2013-01-01

    Full Text Available Snakebites are often believed to be poisonous. However, this is not always the case. In fact, each bite differs from snake to snake, depending on if the snake is poisonous and if there is envenomation. Venom in pit viper snakebites is often associated with local necrosis. The abundant literature selections and research articles justify local myonecrosis due to envenomation, but there is not much in the literature regarding myonecrosis at a site distant from the snakebite. We hereby present a case of a 42-year-old man who was transferred to our emergency department after a rattlesnake bit him twice. The patient, besides developing local myonecrosis at the site of the snakebite, developed necrosis of the scrotum as well as tracheal pressure myonecrosis at the site of the endotracheal tube balloon. In this review, we will attempt to discuss the myonecrosis pathophysiology and management related to the rattle snakebite.

  9. Morphological findings in the tracheal epithelium of dogs exposed to the inhalation of poorly conditioned gases under use of an endotracheal tube or laryngeal mask airway Alterações morfológicas no epitélio traqueal de cães expostos à inalação de gases pouco condicionados, sob ventilação com tubo traqueal ou máscara laríngea

    Directory of Open Access Journals (Sweden)

    Norimar Hernandes Dias

    2011-10-01

    Full Text Available PURPOSE: To study morphological findings in the tracheal epithelium of dogs exposed to the inhalation of poorly conditioned gases under use of an endotracheal tube (ET or laryngeal mask airway (LMA. METHODS: Twelve dogs randomly were allocated to two groups: ET group (n-6 and LMA group (n-6, anaesthetized and mechanically ventilated, without CO2 reabsorption. Haemodynamic and ventilatory parameters, tympanic temperature, temperature, relative and absolute humidity of the ambient and inhaled gases were analyzed during three hours. The animals were submitted to euthanasia and biopsies were carried out along the tracheal segment to morphological study. Three healthy dogs were used to morphological control. RESULTS: Inhaled gas temperature was maintained between 24ºC and 26ºC, relative humidity between 10% and 12%, and absolute humidity between 2 - 3 mg H2O.L-1 with no significant differences between groups. In both groups, histological analysis showed epithelial inflammation and congestion in the corion and scanning electron microscopy showed ciliary grouping and disorganization. Transmission electron microscopy showed higher alterations in ET group than LMA group as widening of cell junctions, ciliary disorientation, cytoplasmic vacuolization, nuclear abnormalities, picnosis and chromatin condensation. CONCLUSION: LMA determined less pronounced changes in the tracheal epithelium in dogs exposed to the inhalation of poorly conditioned gases.OBJETIVO: Avaliar as alterações morfológicas no epitélio traqueal de cães expostos à inalação de gases pouco condicionados, sob ventilação com tubo traqueal (TT ou máscara laríngea (ML. MÉTODOS: Doze cães adultos foram divididos aleatoriamente em dois grupos: grupo TT (n-6 e grupo ML (n-6, submetidos à anestesia venosa e ventilação mecânica, em sistema sem reabsorção de CO2. Foram registrados parâmetros hemodinâmicos e ventilatórios, temperatura timpânica, temperatura, umidade relativa

  10. [Self-expanding nitinol stents in proximal tracheal stenosis].

    Science.gov (United States)

    Hafner, B; Mann, W; Heussel, C P; Scherhag, A; Schlegel, J; Kauczor, H U

    2000-03-01

    The use of silicone- or metal stents in stenosis of the distal trachea and the bronchial system is a customary procedure [1-4], for example after tumor invasion or cicatricial stenosis after transplantation. In the proximal part of the trachea, on smaller, short and soft strictures we try to stabilise the trachea by the implantation of rings. Other methods are tracheal plasty or transverse tracheal resectomy [5-7]. In the case of longer or nearer subglottal stenoses the positioning of self-expanding nitinol stents has proven a simple, gentle and well-tolerated alternative procedure even in very serious disorders [1, 8, 9]. These stents can be placed in short narcosis under endoscopic control without great strain on the patient. We placed nitinol-stents in the proximal part of the trachea in eleven cases. In five cases dyspnoea caused by a tracheal collapse improved. In two further cases a tracheal stenosis with massive granulation tissue and cicatricial pull under an inlaid tracheal cannula was removed and the tracheostoma was closed. In four cases a solid, scarred and cartilaginous stenosis in the area of the cricoid and the upper tracheal rings was widened with laser and later on stented. Over an observation time of two years no complications showed safe one case in which a directly postoperative dislocation was repositioned quickly. The patients live without restrictions through the tracheal stenosis or a tracheostoma. In the best possible case epithelialization over the metal meshes develops so that a nearly normal mucus transportation is possible [1, 10-12].

  11. Multicentre randomised controlled trial to investigate the usefulness of continuous pneumatic regulation of tracheal cuff pressure for reducing ventilator-associated pneumonia in mechanically ventilated severe trauma patients: the AGATE study protocol.

    Science.gov (United States)

    Marjanovic, Nicolas; Frasca, Denis; Asehnoune, Karim; Paugam, Catherine; Lasocki, Sigismond; Ichai, Carole; Lefrant, Jean-Yves; Leone, Marc; Dahyot-Fizelier, Claire; Pottecher, Julien; Falcon, Dominique; Veber, Benoit; Constantin, Jean-Michel; Seguin, Sabrina; Guénézan, Jérémy; Mimoz, Olivier

    2017-08-07

    Severe trauma represents the leading cause of mortality worldwide. While 80% of deaths occur within the first 24 hours after trauma, 20% occur later and are mainly due to healthcare-associated infections, including ventilator-associated pneumonia (VAP). Preventing underinflation of the tracheal cuff is recommended to reduce microaspiration, which plays a major role in the pathogenesis of VAP. Automatic devices facilitate the regulation of tracheal cuff pressure, and their implementation has the potential to reduce VAP. The objective of this work is to determine whether continuous regulation of tracheal cuff pressure using a pneumatic device reduces the incidence of VAP compared with intermittent control in severe trauma patients. This multicentre randomised controlled and open-label trial will include patients suffering from severe trauma who are admitted within the first 24 hours, who require invasive mechanical ventilation to longer than 48 hours. Their tracheal cuff pressure will be monitored either once every 8 hours (control group) or continuously using a pneumatic device (intervention group). The primary end point is the proportion of patients that develop VAP in the intensive care unit (ICU) at day 28. The secondary end points include the proportion of patients that develop VAP in the ICU, early (≤7 days) or late (>7 days) VAP, time until the first VAP diagnosis, the number of ventilator-free days and antibiotic-free days, the length of stay in the ICU, the proportion of patients with ventilator-associated events and that die during their ICU stay. This protocol has been approved by the ethics committee of Poitiers University Hospital, and will be carried out according to the principles of the Declaration of Helsinki and the Good Clinical Practice guidelines. The results of this study will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals. Clinical Trials NCT02534974. © Article author(s) (or

  12. Wear plates control rod guide tubes top internal reactor vessel C. N. VANDELLOS II

    International Nuclear Information System (INIS)

    2010-01-01

    The guide tubes for control rods forming part of the upper internals of the reactor vessel, its function is to guide the control rod to permit its insertion in the reactor core. These guide tubes are suspended from the upper support plate which are fixed by bolts and extending to the upper core plate which is fastened by clamping bolts (split pin) to prevent lateral displacement of the guide tubes, while allowing axial expansion.

  13. Method of fabricating a poision tube for reactor control rods

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Yasuhiko; Yoshida, Toshimi; Masaoka, Isao; Naruse, Akisuke

    1983-04-28

    A method to unify the neutron absorbing performance, enhance the workability in the insertion of neutron absorber tube and further decrease the stresses acting on the neutron absorber coating tube is described. The neutron absorber coated rod comprising neutron absorbing substance and a metal pipe is fabricated by compressing a metal pipe filled with the neutron absorber. Specifically, neutron absorbing substance such as boron carbide powder or the like is filled in a metal pipe such as made of stainless steel tube by way of vibration packing or the like. Then, after heating the metal pipe, it is applied with compression working such as swaging into a fine tube to increase the packing density of the absorbing substance filled in the pipe to greater than 60% of the theoretical density and completely contacted closely to the inner wall of the pipe. The neutron absorber coated rod thus fabricated can be inserted to an external coating tube with ease at a predetermined gap.

  14. Management of benign dynamic "A-shape" tracheal stenosis: a retrospective study of 60 patients.

    Science.gov (United States)

    Plojoux, Jérôme; Laroumagne, Sophie; Vandemoortele, Thomas; Astoul, Philippe J; Thomas, Pascal A; Dutau, Hervé

    2015-02-01

    Benign tracheal stenosis complicates tracheal intubation or tracheostomy in 0.6% to 65% of cases. Surgical resection is the standard treatment. Endoscopic management is used for inoperable patients with 17% to 69% success. Dynamic "A-shape" tracheal stenosis (DATS) results in a dynamic stenosis with anterior fracture of tracheal cartilage and frequently associated posterior malacia. We report the results of our multidisciplinary management. Sixty patients with DATS were included. Management decision was made during initial bronchoscopy. When suitable, patients were referred to thoracic surgery for tracheal resection. Posterior localized tracheomalacia was treated with laser photocoagulation of the posterior tracheal wall. Tracheal stents were placed if the stenosis persisted after laser treatment. The choice of stent (straight silicone, hour-glass shaped silicone, T-tube, or fully-covered self-expandable metallic stent) was based on operator's judgment. After 12 to 18 months, stents were removed. If the stenosis persisted after stent removal, surgery was reconsidered. If surgery was not possible, a stent was replaced. In case of satisfactory result, a stent was replaced only after recurrence. Stable patients after treatment were considered as success, requirement of long-term tracheostomy or T tube as failure, and long-term stent as partial success. All patients developed DATS after tracheostomy. Thirty-three patients had posterior tracheomalacia. In 13 patients, mild stenosis required only endoscopic surveillance. Two patients were referred to thoracic surgery for tracheal resection surgery. Endoscopic management was the initial therapy in 45 patients (75%) and was considered successful in 23 patients (51%), partially successful in 10 (22%), and failed in 12 (27%). Five patients with successful outcomes required only laser therapy. Overall 70 stents were placed in 35 patients, with a migration rate of 31%. The DATS management was successful in 63%. Stent migration

  15. Securing the airway in a child with tracheal agenesis – an alternative perspective

    Directory of Open Access Journals (Sweden)

    Slavomir Nosal

    2011-03-01

    Full Text Available Tracheal agenesis is an extremely rare, typically fatal congenital anomaly characterised by typical clinical manifestation, failed endotracheal intubation and difficult emergency management. The prognosis and possibility of surgical correction rest on early diagnosis, anatomy, birth weight, and associated anomalies. Tracheal agenesis causes considerable resuscitation difficulties immediately after birth, as tracheal intubation is impossible. Although emergency management, by either bag and mask ventilation or oesophageal intubation, provides some pulmonary gas exchange through tracheo-oesophageal connection, they are associated with overdistension of the stomach and the risk of stomach perforation. We have performed selective intubation of the distal trachea in a child with tracheal agenesis through the tracheo-oesophageal connection with the help of a fibroendoscope. A standard guide wire was passed through the working port of the flexible endoscope and under direct vision was directed through the tracheo-oesophageal connection into the distal trachea. At this point, the endoscope was removed, leaving the guide wire in place. The endotracheal tube size 2 Fr was passed over the guide wire into the distal trachea. The infant showed dramatic improvement and maintained good saturations on mechanical ventilation. The infant was taken for a computed tomography (CT scan, which showed Floyd’s type II tracheal agenesis, the oesophagus connecting with the distal trachea before it bifurcates. The endotracheal tube was seen ending in the carina. Transoesophageal intubation of the short distal segment of the trachea through the tracheo-oesophageal connection might offer a new perspective for short-term securing of the airway in a child with tracheal agenesis and should be considered in any child with suspected tracheal agenesis to buy the time while evaluating the exact anatomy of the anomaly and the possibility of tracheal reconstruction in selected

  16. Tracheal quadrifurcation associated with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, Venkatraman; Gadabanahalli, Karthik; Ahmad, Ozaire [Narayana Multispeciality Hospital and Mazumdar Shaw Cancer Center, Department of Radiology, Bangalore (India)

    2015-08-15

    Tracheal anomalies are known in association with congenital cardiac defects. Some of the well-described anomalies include accessory (displaced) tracheal bronchus with variants, tracheal trifurcation and accessory cardiac bronchus. Here we describe a case of tracheal quadrifurcation associated with complex congenital heart disease. Illustration of complex airway anatomy was simplified by the use of multidetector CT using a variety of image display options. Awareness of this complex anomaly will expand our knowledge of tracheal anomalies and equip the anesthesia and surgical team for better airway management. (orig.)

  17. Rescue patient from tracheal obstruction by dislocated bronchial stent during tracheostomy surgery with readily available tools: A case report.

    Science.gov (United States)

    Chang, Hung-Yu; Man, Kee-Ming; Liao, Kate Hsiurong; Chiang, Yi-Ying; Chen, Kuen-Bao

    2017-09-01

    Airway stenting is a well-established method that relieves symptoms and maintains airway patency in patients with airway obstruction. Serious complications caused by airway stents such as stent dislocation and airway obstruction during surgery are life-threatening. An 80-year-old man was treated with bronchial stent for left bronchus obstruction caused by metastatic esophageal cancer. During tracheostomy surgery, he suffered from acute tracheal obstruction caused by dislocated bronchial stent. Esophageal cancer, left bronchus obstruction, respiratory failure, tracheal obstruction. Threading a 5.0-sized endotracheal tube combined with an Eschmann tracheal tube introducer to prop up the collapsed stent. The bronchial stent was re-expanded and threaded into right main bronchus and ventilation restored. Patient with airway stent undergoing surgery with airway involved should be performed under the support of a backup physician and equipment that are capable of handling potentially life-threatening complications of airway stent. If not, in the emergent situation of tracheal obstruction due to tracheal/bronchial stent, protruding through the stent with a suitable, small-sized endotracheal tube with Eschmann tracheal tube introducer may be an alternative skill for saving life weighted with possible complications.

  18. Surface chemistry interventions to control boiler tube fouling

    International Nuclear Information System (INIS)

    Turner, C.W.; Guzonas, D.A.; Klimas, S.J.

    2000-06-01

    The adsorption of ammonia, morpholine, ethanolamine, and dimethylamine onto the surfaces of colloidal magnetite and hematite was measured at 25 o C. The effect of the adsorption on the surface potential was quantified by measuring the resulting shift in the isoelectric point of the corrosion products and by the direct measurement of the surface interaction force between the corrosion products and Inconel 600. These measurements have served to support the hypothesis that adsorption of amine affects the magnetite deposition rate by lowering the force of repulsion between magnetite and the surface of Inconel 600. The deposition rate of hematite increased as the oxygen concentration increased. A mechanism to account for enhanced deposition rates at high mixture qualities (> 0.35) has been identified and shown to predict behaviour that is consistent with both experimental and plant data. As a result of this investigation, several criteria are proposed to reduce the extent of corrosion product deposition on the tube bundle. Low hematite deposition is favoured by a low concentration of dissolved oxygen, and low magnetite deposition is favoured by choosing an amine for pH control that has little tendency to adsorb onto the surface of magnetite. To minimize adsorption the amine should have a high base strength and a large 'footprint' on the surface of magnetite. To prevent enhanced deposition at high mixture qualities, it is proposed that a modified amine be used that will reduce the surface tension or the elasticity of the steam-water interface or both

  19. Surface chemistry interventions to control boiler tube fouling

    Energy Technology Data Exchange (ETDEWEB)

    Turner, C.W.; Guzonas, D.A.; Klimas, S.J

    2000-06-01

    The adsorption of ammonia, morpholine, ethanolamine, and dimethylamine onto the surfaces of colloidal magnetite and hematite was measured at 25{sup o}C. The effect of the adsorption on the surface potential was quantified by measuring the resulting shift in the isoelectric point of the corrosion products and by the direct measurement of the surface interaction force between the corrosion products and Inconel 600. These measurements have served to support the hypothesis that adsorption of amine affects the magnetite deposition rate by lowering the force of repulsion between magnetite and the surface of Inconel 600. The deposition rate of hematite increased as the oxygen concentration increased. A mechanism to account for enhanced deposition rates at high mixture qualities (> 0.35) has been identified and shown to predict behaviour that is consistent with both experimental and plant data. As a result of this investigation, several criteria are proposed to reduce the extent of corrosion product deposition on the tube bundle. Low hematite deposition is favoured by a low concentration of dissolved oxygen, and low magnetite deposition is favoured by choosing an amine for pH control that has little tendency to adsorb onto the surface of magnetite. To minimize adsorption the amine should have a high base strength and a large 'footprint' on the surface of magnetite. To prevent enhanced deposition at high mixture qualities, it is proposed that a modified amine be used that will reduce the surface tension or the elasticity of the steam-water interface or both.

  20. Analysis of DC control in double-inlet GM type pulse tube refrigerators for detectors

    Science.gov (United States)

    Du, B. Y.

    2016-10-01

    Pulse tube refrigerators have demonstrated many advantages with respect to temperature stability, vibration, reliability and lifetime among cryo-coolers for detectors. Double-inlet type pulse tube refrigerators are popular in GM type pulse tube refrigerators. The single double-inlet valve may introduce DC flow in refrigerator, which deteriorates the performance of pulse tube refrigerator. One new type of DC control mode is introduced in this paper. Two parallel-placed needle valves with opposite direction named double-valve configuration, instead of single double-inlet valve, are used in our experiment to reduce the DC flow. With two double-inlet operating, the lowest cold end temperature of 18.1K and a coolant of 1.2W@20K have been obtained. It has proved that this method is useful for controlling DC flow of the pulse tube refrigerators, which is very important to understand the characters of pulse tube refrigerators for detectors.

  1. Intravenous rocuronium 0.3 mg/kg improves the conditions for tracheal intubation in cats: a randomized, placebo-controlled trial.

    Science.gov (United States)

    Sakai, Daniel M; Zornow, Kailee Anne; Campoy, Luis; Cable, Christina; Appel, Leslie D; Putnam, Holly J; Martin-Flores, Manuel

    2018-01-01

    Objectives We evaluated the use of rocuronium 0.3 mg/kg intravenously (IV) to facilitate tracheal intubation in cats anesthetized for elective ovariohysterectomy. Methods Thirty female cats were randomly allocated to receive rocuronium 0.3 mg/kg IV or an equal volume of normal saline, following induction of anesthesia with ketamine and midazolam. Thirty seconds after induction, a single investigator, unaware of treatment allocation, attempted tracheal intubation. The number of attempts and the time to complete intubation were measured. Intubating conditions were assessed as acceptable or unacceptable based on a composite score consisting of five different components. Duration of apnea after induction was measured and cases of hemoglobin desaturation (SpO 2 rocuronium 12 s [range 8-75 s]; saline 60 s [range 9-120 s]) and with fewer attempts (rocuronium 1 [range 1-2]; saline 2 [range 1-3], both P = 0.006) in cats receiving rocuronium. Unacceptable intubating conditions on the first attempt occurred in 3/15 cats with rocuronium and in 10/15 with saline ( P = 0.01). Apnea lasted 4 ± 1.6 mins with rocuronium and 2.3 ± 0.5 mins with saline ( P = 0.0007). No cases of desaturation were observed. Conclusions and relevance Rocuronium 0.3 mg/kg IV improves intubating conditions compared with saline and reduces the time and number of attempts to intubate with only a short period of apnea in cats.

  2. A prehospital use of ITClamp for haemostatic control and fixation of a chest tube

    DEFF Research Database (Denmark)

    Barnung, S; Steinmetz, J

    2014-01-01

    We here present three cases in which a new device, the ITClamp Hemorrhage Control System (Innovative Trauma Care, Inc., Edmonton, Canada), was used for bleeding control and for securing a chest tube.......We here present three cases in which a new device, the ITClamp Hemorrhage Control System (Innovative Trauma Care, Inc., Edmonton, Canada), was used for bleeding control and for securing a chest tube....

  3. Ultrasonography for Proper Endotracheal Tube Placement Confirmation in Out-of-hospital Cardiac Arrest Patients: Two-center Experience

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Conclusion: Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during cardiopulmonary resuscitation without the need for interruption of chest compression.

  4. Application of radioisotope methods of investigation and control techniques in tube production

    International Nuclear Information System (INIS)

    Chizh, V.A.; Drabkin, L.A.

    1975-01-01

    Various spheres of radioactive isotopes application of closed and open type in tube production are described. Due to the usage of radioactive indicator method in combination with physicochemical methods and metallography new data are obtained in the theory and practice of tube centrifugal casting, rolling and pressing. Adsorption properties of lubricants and element distribution in the joint weld region of the big diameter tubes are investigated. The application of radioactive isotopes as ionizing radiation source made it possible to develop some radioisotope methods and instruments for tube wall thickness and the wall thickness difference control. Short characteristics of such instruments are given

  5. Study of scratch-induced stress corrosion cracking for steam generator tubes and scratch control

    International Nuclear Information System (INIS)

    Meng, F.; Xu, X.; Liu, X.; Wang, J.

    2014-01-01

    This paper introduces field cases for scratch-induced stress corrosion cracking (SISCC) of steam generator tubes in PWR and current studies in laboratories. According to analysis result of broke tubes, scratches caused intergranular stress corrosion cracking (IGSCC) with outburst. The effect of microstructure for nickel-base alloys, residual stresses caused by scratching process and water chemistry on SISCC and possible mechanism of SISCC are discussed. The result shows that scratch-induced microstructure evolution contributes to SISCC significantly. The causes of scratches during steam generator tubing manufacturing and installation process are stated and improved reliability with scratch control is highlighted for steam generator tubes in newly built nuclear power plants. (author)

  6. Study of scratch-induced stress corrosion cracking for steam generator tubes and scratch control

    Energy Technology Data Exchange (ETDEWEB)

    Meng, F.; Xu, X.; Liu, X. [Shanghai Nuclear Engineering Research and Design Institute, Shanghai (China); Wang, J. [Chinese Academy of Sciences, Institute of Metal Research, Shenyang (China)

    2014-07-01

    This paper introduces field cases for scratch-induced stress corrosion cracking (SISCC) of steam generator tubes in PWR and current studies in laboratories. According to analysis result of broke tubes, scratches caused intergranular stress corrosion cracking (IGSCC) with outburst. The effect of microstructure for nickel-base alloys, residual stresses caused by scratching process and water chemistry on SISCC and possible mechanism of SISCC are discussed. The result shows that scratch-induced microstructure evolution contributes to SISCC significantly. The causes of scratches during steam generator tubing manufacturing and installation process are stated and improved reliability with scratch control is highlighted for steam generator tubes in newly built nuclear power plants. (author)

  7. Tracheal replacement by autogenous aorta

    Directory of Open Access Journals (Sweden)

    Anoosh Farhad

    2009-06-01

    Full Text Available Abstract Background Tracheal defects may occur after trauma or prolonged intubation. Resection of tracheal tumors also poses a major challenge for substitution. In an effort to solve this problem, different techniques have been tried with little success. We report on a new animal model which showed acceptable results with fewer complications. Methods We replaced 5 cm of cervical trachea in 10 dogs with harvested infra-renal aorta and repaired the aortic defect with Dacron graft. Results Necropsy of the grafted aorta and anastomotic site revealed well healed anastomosis in all animals together with ciliated columnar epithelium coverage of grafted aorta and neovascularization of aortic wall. Conclusion Aortic graft is preferable to other substitutes because of less antigenicity, less vascularity, and no mucous secretions or peristalsis

  8. Tracheal replacement by autogenous aorta.

    Science.gov (United States)

    Anoosh, Farhad; Hodjati, Hossain; Dehghani, Seifollah; Tanideh, Nader; Kumar, Perikala V

    2009-06-09

    Tracheal defects may occur after trauma or prolonged intubation. Resection of tracheal tumors also poses a major challenge for substitution. In an effort to solve this problem, different techniques have been tried with little success. We report on a new animal model which showed acceptable results with fewer complications. We replaced 5 cm of cervical trachea in 10 dogs with harvested infra-renal aorta and repaired the aortic defect with Dacron graft. Necropsy of the grafted aorta and anastomotic site revealed well healed anastomosis in all animals together with ciliated columnar epithelium coverage of grafted aorta and neovascularization of aortic wall. Aortic graft is preferable to other substitutes because of less antigenicity, less vascularity, and no mucous secretions or peristalsis.

  9. Rechargeable biofilm-controlling tubing materials for use in dental unit water lines.

    Science.gov (United States)

    Luo, Jie; Porteous, Nuala; Sun, Yuyu

    2011-08-01

    A simple and practical surface grafting approach was developed to introduce rechargeable N-halamine-based antimicrobial functionality onto the inner surfaces of continuous small-bore polyurethane (PU) dental unit waterline (DUWL) tubing. In this approach, tetrahydrofuran (THF) solution of a free-radical initiator, dicumyl peroxide (DCP), flowed through the PU tubing (inner diameter of 1/16 in., or 1.6 mm) to diffuse DCP into the tubing's inner walls, which was used as initiator in the subsequent grafting polymerization of methacrylamide (MAA) onto the tubing. Upon chlorine bleach treatment, the amide groups of the grafted MAA side chains were transformed into acyclic N-halamines. The reactions were confirmed with attenuated total reflectance infrared (ATR) spectra and iodometric titration. The mechanical properties of the tubing were not significantly affected by the grafting reactions. The biofilm-controlling function of the new N-halamine-based PU tubing was evaluated with Pseudomonas aeruginosa (P. aeruginosa), one of the most isolated water bacteria from DUWLs, in a continuous bacterial flow model. Bacteria culturing and SEM studies showed that the inner surfaces of the new N-halamine-based PU tubing completely prevented bacterial biofilm formation for at least three to four weeks. After that, bacteria began to colonize the tubing surface. However, the lost function was fully regenerated by exposing the tubing inner surfaces to diluted chlorine bleach. The recharging process could be repeated periodically to further extend the biofilm-controlling duration for long-term applications.

  10. The biofilm-controlling functions of rechargeable antimicrobial N-halamine dental unit waterline tubing.

    Science.gov (United States)

    Porteous, Nuala; Schoolfield, John; Luo, Jie; Sun, Yuyu

    2011-01-01

    A study was conducted to test the biofilm-controlling functions of N-halamine tubing over an eight-month period. A laboratory system, simulating a teaching dental clinic, was used to test rechargeable N-halamine tubing (T) compared to an untreated control (C) using the unit manufacturer's tubing. For the long-term study, a recharged tubing (RC) treated with bleach was used to compare with the test (T) and the control (C) tubing. Source tap water was cycled through the lines at 1.4 mL/minute, five minutes on and 25 minutes off, eight hours/day, five days/week. Every three weeks, samples of effluent, recovered adherent bacteria from inside tubing surfaces, and SEM images were examined for bacterial and biofilm growth. After sampling, a recharging solution of chlorine bleach (1 : 10 dilution) was run through T and RC lines, left overnight, and rinsed out the next morning. One-way ANOVAs and Spearman correlations were performed to detect significant differences for T, RC, and C, and determine significance with time period and source water, respectively. Mean log CFU/mL for C effluent > T (p = 0.028), and C tubing > T (p = 0.035). Spearman correlations were significant between effluent and source water level for T (rho = 0.817), and T tubing (0.750); between RC tubing and source water level (rho = 0.836), and time (rho = 0.745); and between C and time (rho = 0.873). SEM imaging confirmed the presence of biofilm inside RC and C, but not inside T. N-halamine tubing completely inhibited biofilm formation without negatively affecting the physical properties of the effluent water. Further research on N-halamine tubing using a pure water source is recommended, as T effluent bacterial levels reflected the source tap water quality and proliferation of planktonic bacteria with no biofilm activity.

  11. Tracheal reconstruction by re-inforced Gore-Tex in esophageal submuscular tunneling: An experimental study

    Directory of Open Access Journals (Sweden)

    Hodjati Hossein

    2011-01-01

    Full Text Available Background: Tracheal reconstructions are aimed at rearranging or replacing parts of the tracheal tissue by different techniques. Here we introduce a new technique for tracheal reconstruction. Methods: In 10 adult dogs, after intubation with an endotracheal tube, a segment of trachea including seven tracheal rings was resected circumferentially. A submuscular tunnel was induced between mucosal and muscular layers of the adjacent esophagus lying right next to the trachea. The esophageal submuscular tunnel starts and ends exactly at the level of distal and proximal ends of tracheal resection, respectively. Inforced Gore-Tex passed through the esophageal submuscular tunnel the distal segment of trachea and end-to-end anastomosis were made between distal ends of Gore-Tex and trachea, then endotracheal tube removed and the same procedure was made for proximal ends of Gore-Tex and trachea. Afterward, the proximal and distal ends of the esophageal tunnel were approximated to proximal and distal tracheal parts over the anastomosis. Results: All dogs, except one due to anesthetic problem, survived and tolerated the operation; the first two dogs experienced postoperative fever, aspiration pneumonia, and died due to tracheoesophageal fistula. All survived animals were eating and barking well. We started to scarify dogs at least 6 and 12 weeks after operation for microscopy and pathologic examination. The Gore-Texes were patent and supported externally with fibrous connective tissue in esophageal tunneling, with in growth of respiratory epithelium on inner surfaces. Conclusion: Air tightness, good re-epithelialization, and relatively no limitation of esophageal length and no risk of luminal collapse are advantages of tracheal reconstruction by submuscular esophageal tunneling. This new method is worthy of further investigation, as it is technically feasible and easy to implement.

  12. Designing a feedback control algorithm for the tube hydroforming process

    DEFF Research Database (Denmark)

    Endelt, Benny Ørtoft; Cheng, Ming; Zhang, Shihong

    2013-01-01

    Tube hydroforming has a broad industrial appeal as the process enables production of geometrically complex parts within a single forming operation. The process is highly flexible with respect to adjustable process parameters (in the present context trajectories for the internal pressure and axial...

  13. Production and quality control of fuel cladding tubes for LWRs

    International Nuclear Information System (INIS)

    Matsuda, Katsuhiko; Hagi, Shigeki; Anada, Hiroyuki; Abe, Hideaki; Hyodo, Shigetoshi

    1994-01-01

    This paper reviews the recent fabrication technology and corrosion resistance study of fuel cladding tubes for LWRs conducted by Sumitomo Metal Industries Ltd. started the research on zircaloy in 1957. In 1980, the factory exclusively for the production of cladding tubes was founded, and the mass production system on full scale was established. Thereafter, the various improvement of the production technology, the development of new products, and the heightening of the performance mainly on the corrosion resistance have been tested and studied. Recently, the works in the production processes were almost automated, and the installation of the production lines advanced, and the stabilization of product quality and the rationalization of costs are promoted. Moreover, the development of the zircaloy cladding tubes having high corrosion resistance has been advanced to cope with the long term cycle operation of LWRs hereafter. The features of zircaloy cladding tubes, the manufacturing processes, the improvement of the manufacturing technology, the improvement of the corrosion resistance and so on are reported. (K.I.)

  14. An ovine tracheal explant culture model for allergic airway inflammation

    Directory of Open Access Journals (Sweden)

    Abeynaike Latasha

    2010-08-01

    Full Text Available Abstract Background The airway epithelium is thought to play an important role in the pathogenesis of asthmatic disease. However, much of our understanding of airway epithelial cell function in asthma has been derived from in vitro studies that may not accurately reflect the interactive cellular and molecular pathways active between different tissue constituents in vivo. Methods Using a sheep model of allergic asthma, tracheal explants from normal sheep and allergic sheep exposed to house dust mite (HDM allergen were established to investigate airway mucosal responses ex vivo. Explants were cultured for up to 48 h and tissues were stained to identify apoptotic cells, goblet cells, mast cells and eosinophils. The release of cytokines (IL-1α, IL-6 and TNF-α by cultured tracheal explants, was assessed by ELISA. Results The general morphology and epithelial structure of the tracheal explants was well maintained in culture although evidence of advanced apoptosis within the mucosal layer was noted after culture for 48 h. The number of alcian blue/PAS positive mucus-secreting cells within the epithelial layer was reduced in all cultured explants compared with pre-cultured (0 h explants, but the loss of staining was most evident in allergic tissues. Mast cell and eosinophil numbers were elevated in the allergic tracheal tissues compared to naïve controls, and in the allergic tissues there was a significant decline in mast cells after 24 h culture in the presence or absence of HDM allergen. IL-6 was released by allergic tracheal explants in culture but was undetected in cultured control explants. Conclusions Sheep tracheal explants maintain characteristics of the airway mucosa that may not be replicated when studying isolated cell populations in vitro. There were key differences identified in explants from allergic compared to control airways and in their responses in culture for 24 h. Importantly, this study establishes the potential for the

  15. Tracheal and Crico-Tracheal Resection and Anastomosis for Malignancies Involving the Thyroid Gland and the Airway.

    Science.gov (United States)

    Piazza, Cesare; Del Bon, Francesca; Barbieri, Diego; Grazioli, Paola; Paderno, Alberto; Perotti, Pietro; Lombardi, Davide; Peretti, Giorgio; Nicolai, Piero

    2016-02-01

    To evaluate outcomes in different malignancies involving the thyroid and infiltrating the airway submitted to tracheal (TRA) or crico-tracheal resection and anastomosis (CTRA). Retrospective charts review of 27 patients affected by thyroid malignancies involving the airway treated by TRA/CTRA in a single academic institution. Kaplan-Meier curves were used to evaluate the overall (OS) and disease-specific (DSS) survivals and local (LC) and loco-regional control (LRC). Impact on survival of age, comorbidities, previous radiotherapy, types of TRA/CTRA, Shin's stage (II, III, IV), grading (well vs poorly differentiated), and length of airway resected was calculated by the log-rank test. Overall survival and DSS at 3 and 5 years were 82.3% and 71.6%, respectively. Local control and LRC in the entire group were 82.3% at 3 and 5 years. Crico-tracheal resection and anastomosis involving the cricoid arch and plate (type C) and tumor differentiation significantly affected OS and DSS (both P < .001). Type C CTRA and tumor differentiation significantly impacted on LC (P = .002 and P = .009, respectively). Grading and extension of CTRA to the cricoid plate are the most important factors for oncologic outcomes in thyroid malignancies infiltrating the airway. Except for poorly differentiated tumors, TRA/CTRA allows adequate LC even in advanced stage lesions involving the crico-tracheal junction. © The Author(s) 2015.

  16. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    1980-01-01

    A specification is given for an energizing and regulating circuit for a gas filled neutron generator tube consisting of a target, an ion source and a replenisher, the circuit consisting of a power supply to provide a negative high voltage to the target and a target current corresponding to the neutron output of the tube, a constant current source, and control means connected to the power supply and to the constant current source, the control means being responsive to the target current to provide a portion of the constant current to the replenisher substantially to regulate the neutron output of the tube. (author)

  17. Laryngeal Preservation in Managing Advanced Tracheal Adenoid Cystic Carcinoma

    Directory of Open Access Journals (Sweden)

    Thavakumar Subramaniam

    2015-01-01

    Full Text Available A 37-year-old male athlete was diagnosed with primary tracheal adenoid cystic carcinoma following investigation for dyspnea, wheeze, and eventual stridor. Preoperative bronchoscopy revealed a highly vascular tumor 4 cm distal to the cricoid with no gross disease extending to the carina. Imaging revealed circumferential tracheal irregularity immediately inferior to the cricoid, with no definite cricoid invasion. Locoregional extension of disease was noted invading the thyroid and abutment of the carotid approximately 180°. Intraoperative findings identified tracheal mucosal disease extending distal to the carina and proximally at the cricothyroid joints where bilateral functional recurrent nerves were preserved. A decision made to preserve the larynx given the inability to fully resect distal tracheal disease. A 5 cm sleeve resection of the trachea was made with a cricotracheal anastomosis following suprahyoidal muscle release and laryngeal drop-down. The patient was treated with adjuvant radiotherapy including platinum based chemotherapy in an effort to maximise local control. PET scanning three months after therapy revealed no FDG uptake locally or distally.

  18. Rac1 controls epithelial tube length through the apical secretion and polarity pathways

    Directory of Open Access Journals (Sweden)

    Kévin Sollier

    2016-01-01

    Full Text Available The morphometric parameters of epithelial tubes are critical to the physiology and homeostasis of most organs. In addition, many human diseases are associated with tube-size defects. Here, we show that Rac1 limits epithelial tube elongation in the developing fly trachea by promoting Rab5-dependent endocytosis of the apical determinant Crumbs. Rac1 is also involved in a positive feedback loop with the septate junction protein Coracle. Thereby, Rac1 precludes paracellular diffusion and contributes to the septate junction-dependent secretion of the chitin-modifying enzymes Vermiform and Serpentine, which restrict epithelial tube length independently of Crumbs. Thus, Rac1 is a critical component of two important pathways controlling epithelial tube morphogenesis.

  19. Laryngeal mask airway guided tracheal intubation in a neonate with the Pierre Robin syndrome

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; Joensen, Henning; Henneberg, Steen Winther

    1995-01-01

    Endotracheal intubation in infants with the Pierre Robin syndrome may sometimes be impossible to accomplish by conventional means. To aid difficult tracheal intubation many different techniques have been described. We present a case, in which we successfully intubated a small-for-date newborn boy...... with the Pierre Robin syndrome by using a modified laryngeal mask airway (no. 1) as a guide for the endotracheal tube. The technique is easy to perform, less traumatic and less time-consuming than multiple attempts at laryngoscopy or blind tracheal intubation....

  20. A Comfortable Solution To Tracheal Anastomosis Protection: Tracheal Retention Sutures.

    Science.gov (United States)

    Karapolat, Sami; Turkyilmaz, Atila; Seyis, Kubra Nur; Tekinbas, Celal

    2018-04-01

    Fixation of the chin to the anterior chest wall is the most commonly used method of reducing anastomotic tension following a segmental resection of the trachea and reconstruction with primary anastomosis. However, the sutures required for this method may lead to various organic and psychological problems. In five patients who underwent tracheal resection and primary anastomosis, retention sutures were placed on the proximal and distal-lateral edges of the anastomotic line rather than placing a Guardian chin stitch. All patients were mobilised in the early postoperative period and were able to perform their routine daily activities without restrictions. During their average 14.4 months of follow-up, no complications were found in their anastomotic lines during their clinical, radiological, and bronchoscopic assessments. The placement of tracheal retention sutures proved an inexpensive and reliable method to reduce anastomotic tension without additional surgical burden, and was effective in terms of patient comfort. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  1. Controlled chloride cracking of austenitic stainless steel tube samples

    OpenAIRE

    Raseroka, M.S.; Pistorius, P.C.

    2009-01-01

    An experimental rig has been constructed to produce chloride stress corrosion cracks in Type 304L stainless steel tube samples. The samples are to be used to test possible in situ repair methods in future work. The factor which influences the time to failure most strongly is the sample temperature; the distribution of cracks within the sample is affected by local temperature variations and by the position of the water line. Low-frequency oscillations in stress, caused by the on-off temperatur...

  2. Quality assurance and quality control in fabrication of heat exchanger tubes

    International Nuclear Information System (INIS)

    Duennewald, A.

    1980-01-01

    Object of this report is the manufacture of heat exchanger tubes. A comprehensive manufacturing and test program has to be established to assure and prove and equal tube quality. This requires a functionally operating quality assurance system combined with a production exactly planned in advance. A specific continuous production line for heat exchanger tubes has been erected at the Hellenthal plant of the Mannesmannroehren-Werke. All production steps and heat treatments are generally controlled by a quality control department. Non-destructive testing of each tube produced in standard length is performed on several agregates in line using ultrasonic and/or eddy current technique. All tests are generally performed in the presence of quality inspectors or surveyors. For a lot of heat exchangers the straight tubes have to be hairpin bended. To avoid the risk of stress corrosion cracking, it is recommended to procreate defined compression stresses in the outside tube surface. Prior to releasing the tubes to shipment, the completeness of the documentation as to the manufacturing steps and inspection agreed upon is thoroughly checked. (RW)

  3. The Eclipse system for surveying the guide tubes of control rod clusters

    International Nuclear Information System (INIS)

    Pace, Y.M.

    2008-01-01

    Eclipse is a new system developed by Areva to assess the wear of the guide tubes of control rod clusters. This system is based on the projection of a shadow on a light plan in order to record the profile and the internal diameter of a hollow tube. This system allows us to quantify the wear and it can be included in a program dedicated to monitor the wear and master its kinetics. This system has been validated on the guide tubes from the Ringhals units. (A.C.)

  4. Improvements to the power supply and control systems of Geiger-Mueller counter tubes

    International Nuclear Information System (INIS)

    Gavin, Gerard; Amberny, Philippe.

    1977-01-01

    This invention aims to provide a power supply and control system for Geiger-Mueller counter tubes requiring only one high voltage output, corresponding to the 'active' phase voltage. With this in view, the invention proposes, inter alia, a system comprising a high voltage source connected to the anode of the GM tube whose cathode is connected to a determination and counting circuit, featuring a cathode connected to the source via an electronic switch and to earth by a component for holding the potential difference at a given level and by another electronic switch, placed in series. The switches are controlled in turn so as alternately to bring the cathode to a first voltage, enabling the tube to function, and to a second voltage, causing the blocking of the tube, this second voltage being set by the component creating the voltage difference [fr

  5. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    Langford, O.M.; Peelman, H.E.

    1980-01-01

    A gas filled neutron tube in a nuclear well logging tool has a target an ion source voltage and a replenisher connected to ground. A negative high voltage is applied to the target by a power supply also providing a target current corresponding to the neutron output of the neutron generator tube. A constant current source provides a constant current. A network receiving the target current and the constant current provides a portion of the constant current as a replenisher current which is applied to the replenisher in a neutron generating tube. The network controls the magnitude of the replenisher current in accordance with the target current so as to control the neutron output of the neutron generating tube. (auth)

  6. Improvements to the power supply and control systems of Geiger-Mueller counter tubes

    Energy Technology Data Exchange (ETDEWEB)

    Gavin, G; Amberny, P

    1977-10-19

    This invention aims to provide a power supply and control system for Geiger-Mueller counter tubes requiring only one high voltage output, corresponding to the 'active' phase voltage. With this in view, the invention proposes, inter alia, a system comprising a high voltage source connected to the anode of the GM tube whose cathode is connected to a determination and counting circuit, featuring a cathode connected to the source via an electronic switch and to earth by a component for holding the potential difference at a given level and by another electronic switch, placed in series. The switches are controlled in turn so as alternately to bring the cathode to a first voltage, enabling the tube to function, and to a second voltage, causing the blocking of the tube, this second voltage being set by the component creating the voltage difference.

  7. Endoscopic Resection of Tracheal Tumor in an Elderly Woman Under Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Yi-Ying Chiang

    2011-03-01

    Full Text Available Anesthetic management of patients with difficult airway is challenging, especially in patients who present with near total occlusion of the airway. Tracheal tumors occur more frequently in elderly patients who are more prone to hypoxic injury. Reliable ventilation and oxygenation are mandatory for a safe and sound intervention. Herein, we report on a 71-year-old woman with a large tracheal tumor occluding approximately 90% of the tracheal lumen. Extracorporeal membrane oxygenation under local anesthesia was used during electrocautery resection of the tumor because of the possibility of fatal airway collapse due to the degree of occlusion and location of the tumor. After the tumor had been successfully resected by means of bronchoscopy, an endotracheal tube was inserted, and the patient was weaned from extracorporeal membrane oxygenation.

  8. Evaluation of friction forces between control bars and guide tubes of CAREM fuel element

    International Nuclear Information System (INIS)

    Ghiselli, Alberto M.; Fiori, Jose M.; Yedros, Pablo A.

    2003-01-01

    The design of the MSAC (Mecanismo del Sistema de ajuste y control, Mechanism of the Adjustment and control system, MACS) for CAREM reactor shall consider all loads that the reactor shall support during its operation. Several charges are originated by friction forces produced on contact points of the control Bars/Guide tubes assembly against other components. A test facility was designed and manufactured for the determination of friction components and the damping characteristics of the assembly formed by guide tubes fuel element, the control bars and the guide of the bar of the MACS. In this work a description of the test performed and the results obtained is presented. (author)

  9. Modelling of the ultrasonic inspection of steel tubes with longitudinal defects; Modelisation du controle ultrasonore de tubes d`acier presentant des defauts de type ``entaille longitudinale``

    Energy Technology Data Exchange (ETDEWEB)

    Mephane, M

    1998-12-31

    A model has been developed in order to simulate the ultrasonic inspection of steel tubes in the Vallourec control configuration. The model permits to simulate the control of steel tubes showing longitudinal defects located near the internal or external surface of tubes which appear during the rolling process. To detect this kind of defect, the probe is placed in an incident place perpendicular to the tube`s axis. The probe is in front of the external surface of the tube. The main characteristics of the model is to assume that the field radiated in the material does not depend on the probe`s position. This assumption permits to treat separately the field retracted in the material and the interaction between the defect and the ultrasonic beam. The focal plane is located in the material, so the plane waves approximation is applied where the waves front are assumed plane and parallel. The parallel refracted beam becomes divergent after reflection on the internal surface of tube. To treat the beam divergence, an amplitude weighting coefficient is then calculated by mean of the energy conservation of a tube of rays before and after reflection, following the Snell laws. This model can predict the edge diffraction echoes, the echoes issued from the corner effect, and also the mode conversion echoes. It has been validated on artificial notches, and on some natural defects. A comparison between experimental and modelling results shows a good agreement. (author) 39 refs.

  10. First-line tracheal resection and primary anastomosis for postintubation tracheal stenosis.

    Science.gov (United States)

    Elsayed, H; Mostafa, A M; Soliman, S; Shoukry, T; El-Nori, A A; El-Bawab, H Y

    2016-07-01

    Introduction Tracheal stenosis following intubation is the most common indication for tracheal resection and reconstruction. Endoscopic dilation is almost always associated with recurrence. This study investigated first-line surgical resection and anastomosis performed in fit patients presenting with postintubation tracheal stenosis. Methods Between February 2011 and November 2014, a prospective study was performed involving patients who underwent first-line tracheal resection and primary anastomosis after presenting with postintubation tracheal stenosis. Results A total of 30 patients (20 male) were operated on. The median age was 23.5 years (range: 13-77 years). Seventeen patients (56.7%) had had previous endoscopic tracheal dilation, four (13.3%) had had tracheal stents inserted prior to surgery and one (3.3%) had undergone previous tracheal resection. Nineteen patients (63.3%) had had a tracheostomy. Eight patients (26.7%) had had no previous tracheal interventions. The median time of intubation in those developing tracheal stenosis was 20.5 days (range: 0-45 days). The median length of hospital stay was 10.5 days (range: 7-21 days). The success rate for anastomoses was 96.7% (29/30). One patient needed a permanent tracheostomy. The in-hospital mortality rate was 3.3%: 1 patient died from a chest infection 21 days after surgery. There was no mortality or morbidity in the group undergoing first-line surgery for de novo tracheal lesions. Conclusions First-line tracheal resection with primary anastomosis is a safe option for the treatment of tracheal stenosis following intubation and obviates the need for repeated dilations. Endoscopic dilation should be reserved for those patients with significant co-morbidities or as a temporary measure in non-equipped centres.

  11. [Investigation of radiation dose for lower tube voltage CT using automatic exposure control].

    Science.gov (United States)

    Takata, Mitsuo; Matsubara, Kousuke; Koshida, Kichirou; Tarohda, Tohru

    2015-04-01

    The purpose of our study was to investigate radiation dose for lower tube voltage CT using automatic exposure control (AEC). An acrylic body phantom was used, and volume CT dose indices (CTDIvol) for tube voltages of 80, 100, 120, and 135 kV were investigated with combination of AEC. Average absorbed dose in the abdomen for 100 and 120 kV were also measured using thermoluminescence dosimeters. In addition, we examined noise characteristics under the same absorbed doses. As a result, the exposure dose was not decreased even when the tube voltage was lowered, and the organ absorbed dose value became approximately 30% high. And the noise was increased under the radiographic condition to be an equal absorbed dose. Therefore, radiation dose increases when AEC is used for lower tube voltage CT under the same standard deviation (SD) setting with 120 kV, and the optimization of SD setting is crucial.

  12. The therapeutic effects and experience of tracheal stent implantation in managing severe tracheal stenosis

    International Nuclear Information System (INIS)

    Lv Weifu; Zhang Xingming; Zhang Xuebing; Wang Weiyu; Hou Changlong

    2006-01-01

    Objective: To evaluate the therapeutic effects and experience of the tracheal stent implantation for the management of severe tracheal stenosis. Materials: Thirteen patients with severe tracheal stenosis of various causes underwent high kilovoltage radiography and computed tomography for evaluating the site, form and extent of the stenosis including 10 at the trachea, 1 at the right main bronchus and 2 at left main bronchus. The C2 catheter assisted with ultra-slipping guide wire was inserted into the trachea under fluoroscopy and then a replaced high shoring guide wire was pushed through the stenotic segment and retained the stent. Results: All stents were implanted successfully with successful rate 100% together with dyspnoeic improvements. The mean survival time was 6.2 months for patients with malignant neoplasm. One patient with benign tracheal stenosis has been followed-up for 5 years without restenosis. Conclusions: The tracheal stent implantation is an effective means for severe tracheal stenosis. (authors)

  13. Tracheal resection and anastomosis after traumatic tracheal stenosis in a horse.

    Science.gov (United States)

    Barnett, Timothy P; Hawkes, Claire S; Dixon, Padraic M

    2015-02-01

    To report a resection and anastomosis technique to treat trauma-induced tracheal stenosis. Case report. A 9-year-old Warmblood gelding. Endoscopy, radiography, and ultrasonography were used to diagnose a single ring tracheal stenosis; the stenotic region was resected and adjacent tracheal rings anastomosed with an end-to-end technique. The anastomosis healed completely despite formation of a unilateral partial mucosal stenosis "web," which was subsequently removed by transendoscopic laser surgery. During tracheal anastomosis, the left recurrent laryngeal nerve was damaged, causing laryngeal hemiplegia, later treated successfully by laryngoplasty. The horse returned to its previous level of work. This tracheal resection and anastomosis technique successfully provided the horse with a large tracheal lumen, and despite major complications, allowed a return to full athletic work. © Copyright 2014 by The American College of Veterinary Surgeons.

  14. Tracheal resection and anastomosis in dogs.

    Science.gov (United States)

    Lau, R E; Schwartz, A; Buergelt, C D

    1980-01-15

    Resection and end-to-end anastomosis of the trachea is a practical procedure for the correction of various forms of tracheal stenosis. Preplacing retention sutures facilitates manipulation of the trachea and rapid apposition of the tracheal ends. These same sutures then relieve tension on the primary suture line, assuring early epithelialization. Two dogs with tracheal stenosis were treated by use of this technique. Slight narrowing of the trachea was evident postoperatively in both dogs, but neither dyspnea nor coughing occurred during the follow-up period.

  15. Flexible Tube-Based Network Control, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Innovation Laboratory, Inc. builds a control system which controls the topology of an air traffic flow network and the network flow properties which enables Air...

  16. Nitinol memmo-alloy stents for benign and malignant tracheal stensis

    International Nuclear Information System (INIS)

    Wang Zhongmin; Wu Chaoxian; Gong Ju; Zheng Yunfeng; Gu Xuezhang

    2005-01-01

    Objective: To observe the therapeutic and side effects of tracheal stents in tracheal stenosis caused by tracheal malacia and malignant tumours. Methods: Twenty-five patients treated with tracheal stents were retrospectively analyzed. Results: Tracheal stents have been implanted successfully in twenty-five patients through fiberbronchoscope or tracheal intubation, and dyspnoea improved greatly after the procedure. Conclusions: Tracheal stents can relieve symptoms and improve the life quality in patients with tracheal stenosis caused by malignant tumors or tracheal malacia. (authors)

  17. Nut tightening and bolt tension measuring apparatus for control guide tube with ultrasonic probe

    International Nuclear Information System (INIS)

    Lanzoni, M.

    1985-01-01

    Control rods are guided by elements set in the prolongation of the fuel assembly guide-tubes in which the control rods are introduced. These elements are inside guide-tubes fixed on the upper plate of the core by means of pins having a thread on which a nut is screwed bearing on the foot of the guide-tube. The pin is fixed inside the upper core plate by means of its lower part. An insufficient mechanical resistance and even failures have been observed with these pins. These failures have been involved by an unadequate screwing. The present invention proposes to control the pretension during the operation itself with an ultrasonic test [fr

  18. Pediatric cuffed endotracheal tubes

    Directory of Open Access Journals (Sweden)

    Neerja Bhardwaj

    2013-01-01

    Full Text Available Endotracheal intubation in children is usually performed utilizing uncuffed endotracheal tubes for conduct of anesthesia as well as for prolonged ventilation in critical care units. However, uncuffed tubes may require multiple changes to avoid excessive air leak, with subsequent environmental pollution making the technique uneconomical. In addition, monitoring of ventilatory parameters, exhaled volumes, and end-expiratory gases may be unreliable. All these problems can be avoided by use of cuffed endotracheal tubes. Besides, cuffed endotracheal tubes may be of advantage in special situations like laparoscopic surgery and in surgical conditions at risk of aspiration. Magnetic resonance imaging (MRI scans in children have found the narrowest portion of larynx at rima glottides. Cuffed endotracheal tubes, therefore, will form a complete seal with low cuff pressure of <15 cm H 2 O without any increase in airway complications. Till recently, the use of cuffed endotracheal tubes was limited by variations in the tube design marketed by different manufacturers. The introduction of a new cuffed endotracheal tube in the market with improved tracheal sealing characteristics may encourage increased safe use of these tubes in clinical practice. A literature search using search words "cuffed endotracheal tube" and "children" from 1980 to January 2012 in PUBMED was conducted. Based on the search, the advantages and potential benefits of cuffed ETT are reviewed in this article.

  19. Conceptual design of a pressure tube light water reactor with variable moderator control

    International Nuclear Information System (INIS)

    Rachamin, R.; Fridman, E.; Galperin, A.

    2012-01-01

    This paper presents the development of innovative pressure tube light water reactor with variable moderator control. The core layout is derived from a CANDU line of reactors in general, and advanced ACR-1000 design in particular. It should be stressed however, that while some of the ACR-1000 mechanical design features are adopted, the core design basics of the reactor proposed here are completely different. First, the inter fuel channels spacing, surrounded by the calandria tank, contains a low pressure gas instead of heavy water moderator. Second, the fuel channel design features an additional/external tube (designated as moderator tube) connected to a separate moderator management system. The moderator management system is design to vary the moderator tube content from 'dry' (gas) to 'flooded' (light water filled). The dynamic variation of the moderator is a unique and very important feature of the proposed design. The moderator variation allows an implementation of the 'breed and burn' mode of operation. The 'breed and burn' mode of operation is implemented by keeping the moderator tube empty ('dry' filled with gas) during the breed part of the fuel depletion and subsequently introducing the moderator by 'flooding' the moderator tube for the 'burn' part. This paper assesses the conceptual feasibility of the proposed concept from a neutronics point of view. (authors)

  20. Rod cluster control assemblies and rod cluster control guide tubes: wear and drop time

    International Nuclear Information System (INIS)

    Zbinden, M.

    1997-01-01

    The wear of RCCAs and of RCC guide tubes is due to two quite different mechanisms and the remedies to apply for each case might lead to contradictory solutions: - the impact/sliding wear for the seldom moving RCCAs, namely the shutdown RCCAs, under flow-induced vibrations, - the axial sliding wear for the control rods subjected to the stepping movements ordered by the acting load. In this case the hydraulic sticking forces are those which produce an evolution of the surface states that may increase the drop time. The introduction, an historical survey of the encountered difficulties, is followed by short description of the components and then the paper presents contributions of EDF in the R and D field, which take place in two successive multi-annual projects. Lastly, some information is given about the recent evolutions and new problems as well for impact/sliding wear as for drop time under normal or seismic conditions. (author)

  1. 21 CFR 878.3720 - Tracheal prosthesis.

    Science.gov (United States)

    2010-04-01

    ...) Identification. The tracheal prosthesis is a rigid, flexible, or expandable tubular device made of a silicone... of the trachea or trachealbronchial tree. It may be unbranched or contain one or two branches. The...

  2. Post intubation tracheal stenosis in children

    Directory of Open Access Journals (Sweden)

    Marco Caruselli

    2014-12-01

    Full Text Available Many authors have reported that tracheal stenosis is a complication that can follow tracheal intubation in both adults and children. The symptoms, when they do appear, can be confused with asthma, with subsequent treatment providing only mild and inconsistent relief. We report here the case of an 8 year old girl admitted to our hospital for whooping cough that was not responding to therapy.

  3. Volume Threshold for Chest Tube Removal: A Randomized ‎Controlled Trial

    Directory of Open Access Journals (Sweden)

    Sajad Hatami

    2009-07-01

    Full Text Available Background: Despite importance of chest tube insertion in chest trauma, there is no ‎general agreement on the level of daily volume drainage from chest tube. This study ‎was conducted to compare the effectiveness and safety of chest tube removal at the ‎levels of 150 ml/day and 2oo ml/day. Methods: Eligible patients (138 who needed replacement of chest tube (because of ‎trauma or malignancy were randomized into two groups; control (removal of chest tube ‎when drainage reached to 150 ml/day and trial (removal of chest tube at the level of ‎‎200 ml/day. All patients received standard care during hospital admission and a follow-‎up visit after 7days of discharge from hospital. Patients were then compared in terms of ‎major clinical outcomes using chi-squared and t-test. Results: From the total of 138 patients, 70 and 68 patients were randomized to control ‎‎(G150 and trial (G200 group, respectively. Baseline characteristics were comparable ‎between the two groups. Although the trial group had a shorter mean for length of ‎hospital stay (LOS (4.1 compared to 4.8, p=0.04, their differences in drainage time ‎did not reach to the level of statistical significance (p=0.1. Analysis of data showed no ‎statistically significant differences between the rate of radiological reaccumulation, ‎thoracentesis and decrease in pulmonary sounds (auscultatory, one week after ‎discharge from hospital.‎‏ ‏Conclusions: Compared to a daily volume drainage of 150 ml, removal of chest tube ‎when there is 200 ml/day is safe and will even result in a shorter hospital stay. This in ‎turn leads to a lower cost.‎

  4. Inverse heat transfer problem in digital temperature control in plate fin and tube heat exchangers

    Science.gov (United States)

    Taler, Dawid; Sury, Adam

    2011-12-01

    The aim of the paper is a steady-state inverse heat transfer problem for plate-fin and tube heat exchangers. The objective of the process control is to adjust the number of fan revolutions per minute so that the water temperature at the heat exchanger outlet is equal to a preset value. Two control techniques were developed. The first is based on the presented mathematical model of the heat exchanger while the second is a digital proportional-integral-derivative (PID) control. The first procedure is very stable. The digital PID controller becomes unstable if the water volumetric flow rate changes significantly. The developed techniques were implemented in digital control system of the water exit temperature in a plate fin and tube heat exchanger. The measured exit temperature of the water was very close to the set value of the temperature if the first method was used. The experiments showed that the PID controller works also well but becomes frequently unstable.

  5. Severe hypoxaemia in field-anaesthetised white rhinoceros (Ceratotherium simum and effects of using tracheal insufflation of oxygen

    Directory of Open Access Journals (Sweden)

    M. Bush

    2004-06-01

    Full Text Available White rhinoceros anaesthetised with etorphine and azaperone combination develop adverse physiological changes including hypoxia, hypercapnia, acidosis, tachycardia and hypertension. These changes are more marked in field-anaesthetised rhinoceros. This study was designed to develop a technique to improve safety for field-anaesthetised white rhinoceros by tracheal intubation and oxygen insufflation. Twenty-five free-ranging white rhinoceros were anaesthetised with an etorphine and azaperone combination for translocation or placing microchips in their horns. Once anaesthetised the rhinoceros were monitored prior to crating for transportation or during microchip placement. Physiological measurements included heart and respiratory rate, blood pressure and arterial blood gas samples. Eighteen rhinoceros were intubated using an equine nasogastric tube passed nasally into the trachea and monitored before and after tracheal insufflation with oxygen. Seven rhinoceros were not intubated or insufflated with oxygen and served as controls. All anaesthetised rhinoceros were initially hypoxaemic (percentage arterial haemoglobin oxygen saturation (% O2Sa = 49 % + 16 (mean + SD and PaO2 = 4.666 + 1.200 kPa (35 + 9 mm Hg, hypercapnic (PaCO2 = 8.265 + 1.600 kPa (62 + 12 mm Hg and acidaemic (pHa = 7.171 + 0.073 . Base excess was -6.7 + 3.9 mmol/ℓ, indicating a mild to moderate metabolic acidosis. The rhinoceros were also hypertensive (systolic blood pressure = 21.861 + 5.465 kPa (164 + 41 mm Hg and tachycardic (HR = 107 + 31/min. Following nasal tracheal intubation and insufflation, the % O2Sa and PaO2 increased while blood pHa and PaCO2 remained unchanged.Tracheal intubation via the nose is not difficult, and when oxygen is insufflated, the PaO2 and the % O2Sa increases, markedly improving the safety of anaesthesia, but this technique does not correct the hypercapnoea or acidosis. After regaining their feet following reversal of the anaesthesia, the animals

  6. Saccular lung cannulation in a ball python (Python regius) to treat a tracheal obstruction.

    Science.gov (United States)

    Myers, Debbie A; Wellehan, James F X; Isaza, Ramiro

    2009-03-01

    An adult male ball python (Python regius) presented in a state of severe dyspnea characterized by open-mouth breathing and vertical positioning of the head and neck. The animal had copious discharge in the tracheal lumen acting as an obstruction. A tube was placed through the body wall into the caudal saccular aspect of the lung to allow the animal to breathe while treatment was initiated. The ball python's dyspnea immediately improved. Diagnostics confirmed a bacterial respiratory infection with predominantly Providencia rettgeri. The saccular lung (air sac) tube was removed after 13 days. Pulmonary endoscopy before closure showed minimal damage with a small amount of hemorrhage in the surrounding muscle tissue. Respiratory disease is a common occurrence in captive snakes and can be associated with significant morbidity and mortality. Saccular lung cannulation is a relatively simple procedure that can alleviate tracheal narrowing or obstruction, similar to air sac cannulation in birds.

  7. Ultrasonic testing of canning tubes in stainless steel of the EL 4 reactor; Controle par ultrasons des tubes de gaine en acier inoxydable du reacteur EL 4

    Energy Technology Data Exchange (ETDEWEB)

    Prot, A; Monnier, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    From all the methods possible for controlling thin cans the one chosen, for numerous reasons, vas that making use of ultrasonic techniques. A method has been developed which should make it possible to carry out a rapid and efficient industrial control of canning tubes, The reasons for the choice of the ultrasonic method are given in detail, together with the principles of the method and the actual control parameters. In the present state of our research, it should be possible to control at least 50 000 tubes a year. Improvements brought about in the details of the control technique itself should make it possible to increase this rate considerably. (authors) [French] Parmi toutes les methodes possibles de controle des gaines minces, le procede retenu pour de multiples raisons a ete celui faisant appel a la technique des ultrasons. Une methode a ete mise au point qui doit permettre un controle industriel rapide et efficace des tubes de gaine. Sont exposes en detail, les raisons du choix de la methode par ultrasons, les principes de cette methode et les parametres du controle proprement dit. Dans l'etat actuel de nos etudes la cadence devrait permettre le controle de 50000 tubes par an au minimum. Des ameliorations de detail portant sur la technique de controle elle-meme, doivent permettre d'accelerer tres notablement cette cadence. (auteurs)

  8. Patients with cardiac arrest are ventilated two times faster than guidelines recommend : An observational prehospital study using tracheal pressure measurement

    NARCIS (Netherlands)

    Maertens, Vicky L.; De Smedt, Lieven E. G.; Lemoyne, Sabine; Huybrechts, Sofie A. M.; Wouters, Kristien; Kalmar, Alain F.; Monsieurs, Koenraad G.

    Aim: To measure ventilation rate using tracheal airway pressures in prehospitally intubated patients with and without cardiac arrest. Methods: Prospective observational study. In 98 patients (57 with and 41 without cardiac arrest) an air-filled catheter was inserted into the endotracheal tube and

  9. Cutting of Control Rod Guide Tubes and Jet Pumps at Wuergassen NPP/ Germany

    International Nuclear Information System (INIS)

    Ralf Loock

    2006-01-01

    KWW Nuclear Power Plant has been erected and put into operation in the time period 1968 to end of 1971. In 23 years of operation about 73 billions kWh electric power have been generated. The electric rated power was 670 MW. In May 1995 the decommission was started for economical reasons, since April 1997 the demolition is in progress. In autumn 2003 FANP has been called upon to cut the Control Rod Guide Tubes and Jet Pumps. After a 10 months preparatory phase, cutting of the Control Rod Guide Tubes and Jet Pumps was started in September 2004. For radiation protection reasons the Control Rod Guide Tubes and Jet Pumps were cut and packed remote controlled under water. The cutting process had been selected particularly under consideration of radiation protection aspects. A combination of the technologies band sawing and nibbling was assigned for cutting of the Control Rod Guide Tubes and Jet Pumps. The band saw consists of a substructure and of a feed system installed on it. The feed system can be equipped with one or two band saws optionally. A turntable is integrated in the substructure. It is used to support the CRGT respectively the residual piece of the CRGT and to move it out of the cut position after finishing the cutting. After getting the agreement to the specification, the equipment has been designed and manufactured according to the specification preferences. After finishing the internal testing, the factory acceptance test as well as acceptance and functional tests of every facility were carried out. After cold testing being performed successfully, the cutting equipment was installed in the NPP and checked for operational safety additionally. Cutting of the Control Rod Guide Tubes and Jet Pumps has been carried out on two working places inside the fuel element storage pool. During the total project duration on site the processing has been supervised by the radiation protection staff permanently. As a result 110 Control Rod Guide Tubes and 18 Jet Pumps were

  10. Damping-controlled fluidelastic instability forces in multi-span tubes with loose supports

    International Nuclear Information System (INIS)

    Hassan, Marwan A.; Rogers, Robert J.; Gerber, Andrew G.

    2011-01-01

    This paper presents simulations of a loosely supported multi-span tube subjected to turbulence and fluidelastic instability forces in order to compare several time-domain fluid force models simulating the damping-controlled fluidelastic instability mechanism in tube arrays. These models include the negative damping model based on the Connors equation, fluid force coefficient-based models (Chen; Tanaka and Takahara), and two semi-analytical models (Price and Paidoussis; and Lever and Weaver). Time domain modelling challenges for each of these theories are discussed. The implemented models are validated against available experimental data. The linear simulations (without tube/support clearance) show that the Connors-equation based model exhibits the most conservative prediction of the critical flow velocity when the recommended design values for the Connors equation are used. The models are then utilized to simulate the nonlinear response of a three-span cantilever tube in a lattice bar support subjected to air crossflow. The tube is subjected to a single-phase flow passing over the spans where the flow velocity and the support clearance are varied. Special attention is paid to the tube/support interaction parameters that affect wear, such as impact forces, contact ratio, and normal work rate. As was seen for the linear cases, the reduced flow velocity at the instability threshold differs for the fluid force models considered. The investigated models do, however, exhibit similar response characteristics for the impact force, tip lift response, and work rate, except for the Connors-based model that overestimates the response and the tube/support interaction parameters for the loose support case, especially at large clearances.

  11. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    Langford, O.M.; Peelman, H.E.

    1978-01-01

    Means and method are described for energizing and regulating a neutron generator tube having a target, an ion source and a replenisher. It providing a negative high voltage to the target and monitoring the target current. A constant current from a constant current source is divided into a shunt current and a replenisher current in accordence with the target current. The replenisher current is applied to the replenisher in a neutron generator tube so as to control the neutron output in accordance with the target current

  12. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    1977-01-01

    A means and method for energizing and regulating a neutron generator tube is described. It has a target, an ion source and a replenisher. A negative high voltage is applied to the target and the target current monitored. A constant current from a constant current source is divided into a shunt current and a replenisher current in accordance with the target current. The replenisher current is applied to the replenisher in a neutron generator tube so as to control the neutron output in accordance with the target current. (C.F.)

  13. Experimental use of new absorbable tracheal stent.

    Science.gov (United States)

    Schopf, Luciano F; Fraga, José Carlos; Porto, Rodrigo; Santos, Luis A; Marques, Douglas R; Sanchez, Paulo R; Meyer, Fabíola S; Ulbrich, Jane M

    2017-11-16

    Silicone and metallic stents are not effective in children with tracheobronchial stenosis or tracheomalacia. Herein, we aimed to evaluate the clinical manifestations and histological reaction of rabbit trachea to the presence of a new poly(lactic-co-glycolic acid) with polyisoprene (PLGA/PI) polymer absorbable stent. Fourteen adult white rabbits (weight, 3.0-3.5kg) were randomly assigned to three groups: Group I (n=6): PLGA/PI spiral stent; Group II (n=6): PLGA/PI fragment; and Group III (n=2): controls. After a longitudinal incision on three cervical tracheal rings, the stents and fragments were inserted into the trachea and fixed onto the lateral wall with nonabsorbable sutures. The stented group showed significantly more stridor at rest (p=0.0041), agitation (p=0.014), and use of accessory muscles (p=0.0002) and required more emergency endoscopies than the fragment group. Further, it showed significantly more remarkable histological inflammatory damage than the fragment and control groups (p=0.002). The new PLGA/PI polymeric stent implanted into the trachea of rabbits caused more clinical manifestations and histologically verified inflammatory reaction than the PLGA/PI polymeric fragment. Future studies should be aimed at reducing the stent-wall thickness. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Comparison of pulsed fluoroscopy by direct control using a grid-controlled x-ray tube with pulsed fluoroscopy by primary control

    International Nuclear Information System (INIS)

    Chida, Koichi; Zuguchi, Masayuki; Ito, Daisuke; Sato, Kunihiko; Shimura, Hirotaka; Sasaki, Masatoshi

    2001-01-01

    Interventional radiology (IVR) procedures may involve high radiation doses that are potentially harmful to the patient. In IVR procedures, pulsed fluoroscopy can greatly decrease the radiation that the physician and patient receive. There are two types of pulsed fluoroscopy: direct control and primary (indirect) control. The purpose of this study was to compare pulsed fluoroscopy by direct control, using a grid-controlled x-ray tube, with pulsed fluoroscopy using primary control. For both types of pulsed fluoroscopy, we measured the waveforms (x-ray tube voltage, x-ray tube current, and x-ray output) and the relative radiation dose. In addition, we compared the decrease in radiation during pulsed fluoroscopy using a care filter. The studies were performed using a Siemens Bicor Plus x-ray System (direct control) and a Siemens Multistar Plus x-ray System (primary control). Using primary pulse control, a 50% decrease in the x-ray output waveform took approximately 0.5-1.0 msec, or longer with a lower x-ray tube current. Using direct pulse control, a 50% decrease in the x-ray output waveform took approximately 0.1 msec, and was independent of x-ray tube current. The rate of radiation reduction with primary pulse control using the care filter with a lower x-ray tube current had a slope exceeding 10%. Pulsed fluoroscopy by direct control using a grid-controlled x-ray tube permits an optimal radiation dose. To decrease the radiation in primary pulse control, a care filter must be used, particularly with a lower x-ray tube current. (author)

  15. Effects of successive tracheal resection and anastomosis on tracheal diameter and position of lobar bronchi in dogs.

    Science.gov (United States)

    de Mello Souza, Carlos Henrique; Reinero, Carol R

    2016-06-01

    OBJECTIVE To evaluate the effects of successive large-segment tracheal resection and anastomosis on tracheal diameter and position of lobar bronchi in dogs. ANIMALS 5 adult Beagles. PROCEDURES Right lateral radiographs were obtained for all dogs and used to measure tracheal length. Dogs were then euthanized, and successive segmental tracheal resections (intervals of 10% from 20% to 50% of the tracheal length), each of which was followed by anastomosis, were performed in each cadaver. Tracheobronchoscopy was performed before the first tracheal resection and after each of the anastomoses to evaluate tracheal diameter and changes in position of lobar bronchi. RESULTS Tracheal diameter was minimally affected by resections up to 50% of the tracheal length. Diameter of the trachea and position of bronchi were not affected by resection of 20% of the tracheal length. Changes in the position of various lobar bronchi were detected after resection of 30% of the tracheal length. CONCLUSIONS AND CLINCIAL RELEVANCE In this study, tracheal resections of 20% of the tracheal length were accommodated, possibly as a result of stretching of the annular ligament. Resections of ≥ 30% of the tracheal length altered the position of lobar bronchi. Clinical effects, if any, attributable to these changes in bronchial position remain to be elucidated.

  16. Indications and interventional options for non-resectable tracheal stenosis

    Science.gov (United States)

    Bacon, Jenny Louise; Patterson, Caroline Marie

    2014-01-01

    Non-specific presentation and normal examination findings in early disease often result in tracheal obstruction being overlooked as a diagnosis until patients present acutely. Once diagnosed, surgical options should be considered, but often patient co-morbidity necessitates other interventional options. Non-resectable tracheal stenosis can be successfully managed by interventional bronchoscopy, with therapeutic options including airway dilatation, local tissue destruction and airway stenting. There are common aspects to the management of tracheal obstruction, tracheomalacia and tracheal fistulae. This paper reviews the pathogenesis, presentation, investigation and management of tracheal disease, with a focus on tracheal obstruction and the role of endotracheal intervention in management. PMID:24624290

  17. Successful use of a bulk laxative to control the diarrhea of tube feeding.

    Science.gov (United States)

    Frank, H A; Green, L C

    1979-01-01

    The greatly increased nutritional demands of the severely burned patient frequently require the use of tube feeding for enternal hyperalimentation. At a time when general patient morale is low and motivation needs to be maximally maintained, there is nothing so dispiriting as the distress of a painful perianal region and uncontrollable liquid stools. Attempts to control the diarrhea which frequently accompanies tube feeding by changing the formula or the method of administration or a wide variety of constipating drugs have all met with very limited success. Based on the clinical observation of a noted gastroenterologist (Bockus), we have administered a mucilagenous hydrophilic colloid bulk laxative (Metamucil) to patients on tube feeding formulae. The dosage and frequency are adjusted to individual patient needs, but average 7 g per liter of liquid formula. The results have been dramatic; namely, the virtual elimination of the diarrhea problem in our burn patients on enteral hyperalimentation by gastric tube feeding. Colonic transit time increases. The stools become formed but soft, cohesive but not adhesive. Perianal irritation does not occur. Neither does soilage of wound, dressings, or bed. No rebound constipation or obstructive symptoms have been encountered. We attribute this response to the same water binding mechanism that allows these colloids to prevent chronic constipation. Our patients may be given as much as 5,000 to 6,000 calories of tube feeding per day. Our patients are not distressed by diarrhea. Our nursing staff is relieved of the burden that entails.

  18. Quality control results of the drift tubes for the ATLAS MDT-BIS chambers

    International Nuclear Information System (INIS)

    Alexopoulos, T.; Avramidou, R.; Dris, M.; Filippas, T.A.; Gazis, E.N.; Katsoufis, E.; Maltezos, S.; Savva, P.; Tsipolitis, G.; Tzamariudaki, E.

    2006-01-01

    ATLAS (A Toroidal LHC ApparatuS) is a general purpose experiment, which will start its operation at the Large Hadron Collider (LHC) at CERN in 2007. The ATLAS detector is designed to study the products of proton-proton collisions at c.m.s. energies of up to 14 TeV. Three Greek Universities have taken the responsibility to construct 112 BIS-MDT (Barrel Inner Small) chambers using 29 000 drift tubes of 170 cm length and 3 cm diameter that have been quality tested before assembly. This work describes the Quality Assurance and Quality Control (QA Q C) procedures for the drift tubes, followed at the High Energy Physics Laboratory of the National Technical University of Athens, while emphasis is given on the obtained results for the above mentioned number of tubes

  19. A microfluidic tubing method and its application for controlled synthesis of polymeric nanoparticles.

    Science.gov (United States)

    Wang, Jidong; Chen, Wenwen; Sun, Jiashu; Liu, Chao; Yin, Qifang; Zhang, Lu; Xianyu, Yunlei; Shi, Xinghua; Hu, Guoqing; Jiang, Xingyu

    2014-05-21

    This report describes a straightforward but robust tubing method for connecting polydimethylsiloxane (PDMS) microfluidic devices to external equipment. The interconnection is irreversible and can sustain a pressure of up to 4.5 MPa that is characterized experimentally and theoretically. To demonstrate applications of this high-pressure tubing technique, we fabricate a semicircular microfluidic channel to implement a high-throughput, size-controlled synthesis of poly(lactic-co-glycolic acid) (PLGA) nanoparticles ranging from 55 to 135 nm in diameter. This microfluidic device allows for a total flow rate of 410 mL h(-1), resulting in enhanced convective mixing which can be utilized to precipitate small size nanoparticles with a good dispersion. We expect that this tubing technique would be widely used in microfluidic chips for nanoparticle synthesis, cell manipulation, and potentially nanofluidic applications.

  20. Management of complex benign post-tracheostomy tracheal stenosis with bronchoscopic insertion of silicon tracheal stents, in patients with failed or contraindicated surgical reconstruction of trachea.

    Science.gov (United States)

    Tsakiridis, Kosmas; Darwiche, Kaid; Visouli, Aikaterini N; Zarogoulidis, Paul; Machairiotis, Nikolaos; Christofis, Christos; Stylianaki, Aikaterini; Katsikogiannis, Nikolaos; Mpakas, Andreas; Courcoutsakis, Nicolaos; Zarogoulidis, Konstantinos

    2012-11-01

    Tracheal stenosis is a potentially life-threatening condition. Tracheostomy and endotracheal intubation remain the commonest causes of benign stenosis, despite improvements in design and management of tubes. Post-tracheostomy stenosis is more frequently encountered due to earlier performance of tracheostomy in the intensive care units, while the incidence of post-intubation stenosis has decreased with application of high-volume, low-pressure cuffs. In symptomatic benign tracheal stenosis the gold standard is surgical reconstruction (often after interventional bronchoscopy). Stenting is reserved for symptomatic tracheal narrowing deemed inoperable, due to local or general reasons: long strictures, inflammation, poor respiratory, cardiac or neurological status. When stenting is decided, silicone stent insertion is considered the treatment of choice in the presence of inflammation and/or when removal is desirable. We inserted tracheal silicone stents (Dumon) under general anaesthesia through rigid bronchoscopy in two patients with benign post-tracheostomy stenosis: a 39-year old woman with failed initial operation, and continuous relapses with proliferation after multiple bronchscopic interventions, and a 20-year old man in a poor neurological status, with a long tracheal stricture involving the subglottic larynx (lower posterior part), and inflamed tracheostomy site tissues (positive for methicillin resistant staphylococcus aureus). The airway was immediately re-establish, without complications. At 15- and 10-month follow-up (respectively) there was no stent migration, luminal patency was maintained without: adjacent structure erosion, secretion adherence inside the stents, granulation at the ends. Tracheostomy tissue inflammation was resolved (2(nd) patient), new infection was not noted. The patients maintain good respiratory function and will be evaluated for scheduled stent removal. Silicone stents are removable, resistant to microbial colonization and are

  1. Ex vivo tracheomalacia model with 3D-printed external tracheal splint.

    Science.gov (United States)

    Kaye, Rachel; Goldstein, Todd; Aronowitz, Danielle; Grande, Daniel A; Zeltsman, David; Smith, Lee P

    2017-04-01

    To design and evaluate an ex vivo model of tracheomalacia with and without a three-dimensional (3D)-printed external tracheal splint. Prospective, ex vivo animal trial. Three groups of ex vivo porcine tracheas were used: 1) control (unmanipulated trachea), 2) tracheomalacia (tracheal rings partially incised and crushed), and 3) splinted tracheomalacia (external custom tracheal splint fitted onto group 2 trachea). Each end of an ex vivo trachea was sealed with a custom-designed and 3D-printed cap; a transducer was placed through one end to measure the pressure inside the trachea. Although the negative pressure was applied to the tracheal lumen, the tracheal wall collapse was measured externally and internally using a bronchoscope. Each group had at least three recorded trials. Tracheal diameter was evaluated using ImageJ software (National Institutes of Health, Bethesda, MD) and was averaged between two raters. Average tracheal occlusion percentage was compared using Student t test. The average occlusion was 31% for group 1, 87.4% for group 2, and 20% for group 3. Significant differences were found between the control and tracheomalacia groups (P tracheomalacia and splinted tracheomalacia groups (P tracheomalacia groups (P = 0.13). Applied pressure was plotted against occlusion and regression line slope differed between the tracheomalacia (0.91) and control (0.12) or splinted tracheomalacia (0.39) groups. We demonstrate the potential for an ex vivo tracheomalacia model to reproduce airway collapse and show that this collapse can be treated successfully with a 3D-printed external splint. These results are promising and justify further studies. N/A. Laryngoscope, 127:950-955, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  2. Numerical calculation for flow field of servo-tube guided hydraulic control rod driving system

    International Nuclear Information System (INIS)

    He Keyu; Han Weishi

    2010-01-01

    A new-style hydraulic control rod driving mechanism was put forward by using servo-tube control elements for the design of control rod driving mechanism. The results of numerical simulation by CFD program Fluent for flow field of hydraulic driving cylinder indicate that the bigger the outer diameter of servo-tube, the smaller the resistance coefficient of variable throttle orifice. The zero position gap of variable throttle orifice could be determined on 0.2 mm in the design. The pressure difference between the upper and nether surfaces of piston was mainly created by the throttle function of fixed throttle orifice. It can be effectively controlled by changing the gap of variable throttle orifice. And the lift force of driving cylinder is able to meet the requirement on the design load. (authors)

  3. Evaluation of tracheal bronchus in Chinese children using multidetector CT

    International Nuclear Information System (INIS)

    Ming, Zhu; Lin, Zhang

    2007-01-01

    Tracheal bronchus is a congenital bronchial anomaly. The diagnosis should be considered early in intubated patients. Multidetector computed tomography (MDCT) is the newest modality for evaluating tracheal bronchus. To evaluate the utility of 16-slice MDCT in children with tracheal bronchus and to characterize the frequency of tracheal bronchus in children with congenital heart disease. From June 2005 to May 2007, 3,187 consecutive children (1,124 with congenital heart disease and 2,063 without congenital heart disease) underwent MDCT examination. Minimum-intensity projection reconstruction was performed to show the tracheobronchial tree in every case. Tracheal bronchus was found in 42 children (3.74%) with congenital heart disease but in only 6 children (0.29%) without congenital heart disease. Among the 48 children with tracheal bronchus, 45 had right-side tracheal bronchus and 3 had bilateral tracheal bronchi with heterotaxy syndrome. The diagnostic sensitivity of MDCT was 100% (48/48). MDCT is a reliable imaging technique for the diagnosis of tracheal bronchus. Our data showed that right-side tracheal bronchus was more common and bilateral tracheal bronchi usually occurred with heterotaxy syndrome. In addition, tracheal bronchus often occurred with congenital heart disease. The angle between the tracheal bronchus and the trachea is important and should be measured. (orig.)

  4. Management of Tracheal Deformity During Intubation: A Case Report

    Directory of Open Access Journals (Sweden)

    Sheng-Hua Wu

    2007-06-01

    Full Text Available Failure or difficulty in intubating the trachea can be either due to inability to visualize the glottis or some pathology at the level of or below the cords. This report describes a case of difficult intubation suspected of being related to neck scarring from previous surgery. Computed tomography (CT was used to evaluate the patient's airway and revealed upper tracheal angulation. We describe a method to secure the airway in this patient with a two-person technique by rotating an oral endotracheal tube 180° counterclockwise to adjust to the curvature of the trachea. Problems with intubation should be anticipated in patients with scarring of the neck, and equipment for aiding intubation should be on hand. Furthermore, we found that CT contributed to the assessment of the difficulty of intubation in this kind of patient.

  5. Influence of structure improvement of guide tubes and bundles in pressurized water reactor (PWR) on drop of control rods

    International Nuclear Information System (INIS)

    Shen Xiuzhong; Yu Pingan; Yang Guanyue

    1996-01-01

    In order to alleviate the cross hydraulic load on control rod guide tubes and bundles, some protective sleeves are added to those near the upper plenum outlet nozzles (4 symmetric bundles: 02-26, 03-25, 11-29, 12-28). In a 1/4 scale transparent model of the PWR upper plenum of Qinshan Nuclear Power Station, water was chosen as the fluid and hydraulic experiments with improved control rod guide tubes and bundles were carried out. The results were carefully compared with those of the experiments with unimproved control rod guide tubes and bundles. It is concluded that adding protective sleeves to the control rod guide tubes and bundles near the outlet nozzles will help to lighten the hydraulic load on them and make certain of the free movement and rapid dropping of control rods in the tubes and bundles in emergency by order

  6. Support vector regression model based predictive control of water level of U-tube steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Kavaklioglu, Kadir, E-mail: kadir.kavaklioglu@pau.edu.tr

    2014-10-15

    Highlights: • Water level of U-tube steam generators was controlled in a model predictive fashion. • Models for steam generator water level were built using support vector regression. • Cost function minimization for future optimal controls was performed by using the steepest descent method. • The results indicated the feasibility of the proposed method. - Abstract: A predictive control algorithm using support vector regression based models was proposed for controlling the water level of U-tube steam generators of pressurized water reactors. Steam generator data were obtained using a transfer function model of U-tube steam generators. Support vector regression based models were built using a time series type model structure for five different operating powers. Feedwater flow controls were calculated by minimizing a cost function that includes the level error, the feedwater change and the mismatch between feedwater and steam flow rates. Proposed algorithm was applied for a scenario consisting of a level setpoint change and a steam flow disturbance. The results showed that steam generator level can be controlled at all powers effectively by the proposed method.

  7. Intermittent subglottic secretion drainage may cause tracheal damage in patients with few oropharyngeal secretions.

    Science.gov (United States)

    Suys, E; Nieboer, K; Stiers, W; De Regt, J; Huyghens, L; Spapen, H

    2013-12-01

    Injurious prolapse of tracheal mucosa into the suction port has been reported in up to 50% of intubated patients receiving continuous aspiration of subglottic secretions. We investigated whether similar injury could be inflicted by automated intermittent aspiration. Six consecutive patients, intubated with the Mallinckrodt TaperGuard Evac™ endotracheal tube, were studied. A flow sensor was placed between the vacuum regulating system and the mucus collector. Intermittent suctioning was performed at a pressure of -125 mmHg with a 25s interval and duration of 15s. After 24h, a CT scan of the tracheal region was performed. Excessive negative suction pressure, a fast drop in aspiration flow to zero, and important "swinging" movements of secretions in the evacuation line were observed in all patients. Oral instillation of antiseptic mouthwash restored normal aspiration flow and secretion mobility. CT imaging showed marked entrapment of tracheal mucosa into the suction port in all patients. In patients with few oropharyngeal secretions, automated intermittent subglottic aspiration may result in significant and potential harmful invagination of tracheal mucosa into the suction lumen. A critical amount of fluid must be present in the oropharynx to assure adequate and safe aspiration. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Flow mixing inside a control-rod guide tube – Experimental tests and CFD simulations

    International Nuclear Information System (INIS)

    Angele, Kristian; Odemark, Ylva; Cehlin, Mathias; Hemström, Bengt; Högström, Carl-Maikel; Henriksson, Mats; Tinoco, Hernan; Lindqvist, Hans

    2011-01-01

    This paper covers a combined experimental and computational effort carried out at Vattenfall Research and Development AB in order to study the thermal mixing in the annular region between a top tube and a control-rod stem. The low frequency thermal fluctuations in this region can result in problems with thermal fatigue and have caused cracks in the control-rod stems of several nuclear reactors (). The flow in the vertical annular region formed by the top tube and the control-rod stem is characterized by the mixing of hot bypass flow with cold crud-removal flow. The crud-removal flow is flowing upwards along the control-rod stem, and the warmer bypass flow is entering through eight horizontal holes positioned in the lower part of the guide tube and four holes in the upper part of the top tube, forming jets. Two full-scale models of a control rod, including the control-rod stem and the guide tube, were constructed. The first model, designed to work at atmospheric conditions, was made of Plexiglass, in order to be able to visualize the mixing process, whereas the second one was made of steel to allow for a higher temperature difference between the two flows, and the heating of the top tube. CFD simulations of the case at atmospheric conditions were also carried out. Both the experiments and the simulations showed that the mixing region between the cold crud-removal flow and the warm bypass flow is dominated by large flow structures coming from above. The process is characterized by low frequency, high amplitude temperature fluctuations. The process is basically hydrodynamic, caused by the downward transport of flow structures originated at the upper bypass inlets. The damping thermal effects through buoyancy is of secondary importance, as also the scaling analysis shows, however a slight damping of the temperature fluctuations can be seen due to natural convection due to a pre-heating of the cold crud-removal flow. The comparison between numerical and experimental

  9. [Segmental tracheal resection and anastomosis for the treatment of cicatricial stenosis in cervical tracheal].

    Science.gov (United States)

    Cui, P C; Luo, J S; Liu, Z; Bian, K; Guo, Z H; Ma, R N

    2016-02-01

    To evaluate the efficacy of segmental tracheal resection with end-to-end anastomosis for cicatricial cervical tracheal stenosis. The clinical outcomes of 40 patients treated with tracheal resection were retrospectively reviewed. There were 28 male patients and 12 female patients with the age ranged from 6 to 64 years (mean 33.7 years). The degree of stenosis was classified according to Myer-Cotton classification as follows: grade Ⅱ (n=7), grade Ⅲ (n=22) and grade Ⅳ (n=11). The stenosis extension ranged from 1.0 to 4.3 cm (mean 2.5 cm). The causes of the stenosis were postintubation (n=33), cervical trauma (n=6) and resection of tracheal neoplasm (n=1). Thirty-four(85.0%) patients were decannulated and 6 failed. Of the 6 patients failed, 4 were decannulated after reoperation with the sternohyoid myocutaneous flap or thyroid alar cartilage graft. Complications occurred in 10 patients. In 8 patients granulation tissues formed at the site of the tracheal anastomosis, which needed endoscopic resction, and in 2 patients anastomosic dehiscence occurred. No injury to recurrent laryngeal nerve or trachoesophageal fistula occurred. Segmental tracheal resection with end-to-end anastomosis is an effective surgical method for tracheal stenosis, which has a higher successful rate for primary operation and shorter therapeutic period.

  10. Mathematical modeling and control of plate fin and tube heat exchangers

    International Nuclear Information System (INIS)

    Taler, Dawid

    2015-01-01

    Highlights: • A method for numerical modeling of plate fin and tube heat exchangers was proposed. • A numerical model of an automobile radiator was developed. • Numerical models of the radiator were compared with an exact analytical model. • A model-based control system of water outlet temperature was built and tested. • A digital proportional–integral–derivative controller of heat exchanger was tested. - Abstract: The aim of the study is to develop a new method for numerical modeling of tubular cross-flow heat exchangers. Using the method proposed in the paper, a numerical model of a car radiator was developed and implemented in a digital control system of the radiator. To evaluate the accuracy of the numerical method proposed in the paper, the numerical model of the car radiator was compared with an analytic model. The proposed method based on a finite volume method and integral averaging of gas temperature across a tube row is appropriate for modeling of plate fin and tube heat exchangers, especially for exchangers in which substantial gas temperature differences in one tube row occur. The target of control is to regulate the number of fan revolutions per minute so that the water temperature at the heat exchanger outlet is equal to a set value. Two control techniques were developed. The first is based on the numerical model of the heat exchanger developed in the paper while the second is a digital proportional–integral–derivative control. The first control method is very stable. The digital proportional–integral–derivative controller becomes unstable when the water volume flow rate varies considerably. The developed techniques were implemented in digital control system of the water exit temperature in a plate fin and tube heat exchanger. The measured exit temperature of the water was very close to the set value of the temperature if the first method was used. The experiments show that the proportional–integral–derivative controller

  11. Eustachian tube patency

    Science.gov (United States)

    Eustachian tube patency refers to how much the eustachian tube is open. The eustachian tube runs between the middle ear and the throat. It controls the pressure behind the eardrum and middle ear space. This helps keep ...

  12. Freezing controlled penetration of molten metals flowing through stainless steel tubes

    International Nuclear Information System (INIS)

    Sienicki, J.J.; Spencer, B.W.; Vetter, D.L.; Wesel, R.H.

    1985-01-01

    The freezing controlled penetration potential of molten metals flowing within stainless steel structure is important to the safety assessment of hypothetical severe accidents in liquid metal reactors. A series of scoping experiments has been performed in which molten stainless steel and nickel at various initial temperatures and driving pressures were injected downward and upward into 6.4 and 3.3 mm ID stainless steel tubes filled with argon gas and initially at room temperature. In all tests, there was no evidence that the solid tube wall was wetted by the molten metals. The penetration phenomena are markedly different for downward versus upward injections. The dependency upon tube orientation is explained in terms of the absence of wetting. Complete plugs were formed in all experiments halting the continued injection of melt. Calculations with a fluid dynamics/heat transfer computer code show that the injected masses limited by plugging are consistent with freezing through the growth of a stable solidified layer (crust) of metal upon the solid tube wall. 23 refs., 5 figs., 2 tabs

  13. Remote-controlled television for locating leaking tubes in pressurized-water reactor steam generators

    International Nuclear Information System (INIS)

    Cormault, P.; Denis, J.

    1978-01-01

    The Scarabee system is designed for observation of the tubes in water boxes of pressurized-water reactor nuclear-power-station steam generators. It consists essentially of a camera and a projector used as a marker, both of which swivel freely. The whole unit is housed in a water-tight container which can easily be decontaminated. Remote control of camera and marker movement is carried out from a console. (author)

  14. The use of scaning electron microscopy in postvaccinal evaluation of tracheal epithelium of Coturnix coturnix japonica

    Directory of Open Access Journals (Sweden)

    Santin Elizabeth

    2003-01-01

    Full Text Available This study aimed at evaluating the use of scanning electron microscopy in the study of the post-vaccinal respiratory reaction of the tracheal epithelium of quails (Coturnix coturnix japonica immunized against Newcastle disease. A number of 36 quails were distributed into four groups: T1 fraction three-quarters control birds (non-vaccinated; T2 fraction three-quarters birds vaccinated with Ulster 2C strain; t3 fraction three-quarters birds vaccinated with B1 strain; t4 fraction three-quarters birds vaccinated with LaSota strain. Regardless the experimental group, birds did not show detectable clinical signs of post-vaccinal respiratory reaction. However, the analysis of tracheal fragments by scanning electron microscopy showed that birds vaccinated with B1 and LaSota strains developed epithelial sloughing of the trachea, whereas those vaccinated Ulster 2C strain did not develop this change, demonstrating intact tracheal epithelium, similar to the control group.

  15. U-tube steam generator modelling: application to level control and comparison with plant data

    International Nuclear Information System (INIS)

    Gautier, A.; Petetrot, J.F.; Roulet, A.; Ruiz, P.; Zwingelstein, G.

    1979-01-01

    A nonlinear multinode digital model of a recirculating U-tube steam generator is first described. Comparison between the model and Fessenheim and Bugey tests results on power step and full load rejection is given. These transients are of special interest because they provide information on the boiler high frequency response and also insights into steam generator non linear behaviour. An example of steam generator modelling as applied to control system design is then presented. This example demonstrates major improvement of control loop performance at low load following implementation of a non linear gain which allows more efficient control of large perturbations. Results of testing on the Bugey 4 plant are also indicated

  16. Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation.

    LENUS (Irish Health Repository)

    Maharaj, C H

    2008-02-01

    The Airtraq, a novel single use indirect laryngoscope, has demonstrated promise in the normal and simulated difficult airway. We compared the ease of intubation using the Airtraq with the Macintosh laryngoscope, in patients at increased risk for difficult tracheal intubation, in a randomised, controlled clinical trial. Forty consenting patients presenting for surgery requiring tracheal intubation, who were deemed to possess at least three characteristics indicating an increased risk for difficulty in tracheal intubation, were randomly assigned to undergo tracheal intubation using a Macintosh (n = 20) or Airtraq (n = 20) laryngoscope. All patients were intubated by one of three anaesthetists experienced in the use of both laryngoscopes. Four patients were not successfully intubated with the Macintosh laryngoscope, but were intubated successfully with the Airtraq. The Airtraq reduced the duration of intubation attempts (mean (SD); 13.4 (6.3) vs 47.7 (8.5) s), the need for additional manoeuvres, and the intubation difficulty score (0.4 (0.8) vs 7.7 (3.0)). Tracheal intubation with the Airtraq also reduced the degree of haemodynamic stimulation and minor trauma compared to the Macintosh laryngoscope.

  17. Development of a control system for shell and tube heat exchanger in Matlab simulink

    International Nuclear Information System (INIS)

    Zeeshan, H.M.

    2014-01-01

    The main objective of this research is to develop a control system for heat exchanger so that the desired outlet temperature can be achieved by controlling the flow rate. For this purpose, shell and tube heat exchanger was chosen and modeled it by using its mathematical equations in MATLAB (Matrix Laboratory) Simulink and calculated the outlet temperature by NTU (Number of Transfer Units) effectiveness method. For the purpose of Control system, MPC (Model Predictive Controller) was used. This research will open a new way of Modeling Equations instead of transfer functions in MATLAB (Matrix Laboratory) Simulink. Using the model, it was developed; with controller, so as to manipulate the output temperature by simply controlling the flow rate. It can be justified weather the design of a new heat exchanger would be feasible or not for the specific requirements. At last this research is very helpful in Industries for the purpose of designing, development and control of new Heat Exchangers. (author)

  18. Sensing system for detection and control of deposition on pendant tubes in recovery and power boilers

    Science.gov (United States)

    Kychakoff, George [Maple Valley, WA; Afromowitz, Martin A [Mercer Island, WA; Hogle, Richard E [Olympia, WA

    2008-10-14

    A system for detection and control of deposition on pendant tubes in recovery and power boilers includes one or more deposit monitoring sensors operating in infrared regions of about 4 or 8.7 microns and directly producing images of the interior of the boiler, or producing feeding signals to a data processing system for information to enable a distributed control system by which the boilers are operated to operate said boilers more efficiently. The data processing system includes an image pre-processing circuit in which a 2-D image formed by the video data input is captured, and includes a low pass filter for performing noise filtering of said video input. It also includes an image compensation system for array compensation to correct for pixel variation and dead cells, etc., and for correcting geometric distortion. An image segmentation module receives a cleaned image from the image pre-processing circuit for separating the image of the recovery boiler interior into background, pendant tubes, and deposition. It also accomplishes thresholding/clustering on gray scale/texture and makes morphological transforms to smooth regions, and identifies regions by connected components. An image-understanding unit receives a segmented image sent from the image segmentation module and matches derived regions to a 3-D model of said boiler. It derives a 3-D structure the deposition on pendant tubes in the boiler and provides the information about deposits to the plant distributed control system for more efficient operation of the plant pendant tube cleaning and operating systems.

  19. [Cervical tracheal resection with primary anastomosis for benign tracheal stricture in adult].

    Science.gov (United States)

    Ye, Jin; Hu, Yan-Ming; Liu, Hui; Li, Jing-Jia; Wang, Zhi-Yuan; Li, Yuan

    2013-07-01

    To introduce the outcomes of tracheal resection with primary end to end anastomosis for benign cervical tracheal stenosis, and to discuss the strategy for prevention of surgical complications. A retrospective analysis was performed in 12 patients diagnosed as benign cervical tracheal stenosis from October 2009 to June 2012. Laryngo-tracheal endoscopic examination and computed tomography (CT) were used to assess the degree of stenosis, the grade of inflammation and edema of the subglottis and trachea, and the extent of stenosis and the remaining linear amount of normal airway. The Meyer and Cotton grading system was used to categorise the clinical severity of the stenoses. All patients underwent tracheal resection with primary end to end anastomosis. The length of cervical tracheal stenosis ranged from 2.3 to 4.1 cm. Grade II stenosis was present in three patients, Grade III stenosis was present in seven patients and grade IV stenosis in two patients. Successful extubation was achieved in all 12 cases. After surgery, temporary hoarseness occurred in 1 patient (8.3%); unilateral pulmonary atelectasis with pleural effusion occurred in 1 patient (8.3%); subcutaneous emphysema with infection occurred in 1 patient (8.3%); mild dysphagia occurred in 3 patients (25.0%); a slight deepening of the tone of voice occurred in 5 patients (41.7%), granulation tissue growth near the suture occurred in 3 patients (25.0%), and suture dehiscence did not occur in any patient. The follow-up period ranged from 6 months to 38 months, no patient developed restenosis. It presents a high success rate and good functional result of tracheal resection with primary end-to-end anastomosis. Therefore, it is an effective and reliable approach for the management of benign cervical tracheal stenosis. To avoid complications, the preoperative assessment, patients selection and postoperative management should be emphasized.

  20. Tracheal anastomosis using indocyanine green dye enhanced fibrinogen with a near-infrared diode laser

    Science.gov (United States)

    Auteri, Joseph S.; Jeevanandam, Valluvan; Oz, Mehmet C.; Libutti, Steven K.; Kirby, Thomas J.; Smith, Craig R.; Treat, Michael R.

    1990-06-01

    A major obstacle to lung transplantation and combined heart- lung transplantation is dehiscence of the tracheobronchial anastomosis. We explored the possibility of laser welded anastomoses in canine tracheas in vivo. Laser anastomoses were performed on three-quarter circumferential anterior tracheotomies. A continous wave diode laser (808 +1 nm) at a power density of 9.6 watts/cm was used. Human fibrinogen was mixed with indocyanine green dye (ICG, max absorbance 805 nm) and applied to the anastomosis site prior to laser exposure. Animals were sacrificed at 0, 21 and 28 days post-operatively. At sacrifice weld bursting pressures were measured by raising intratracheal pressure using forced ventilation via an endotracheal tube. Sutured and laser welded anastomoses had similar bursting pressures, and exhibited satisfactory histologic evidence of healing. However, compared to polypropylene sutured controls, the laser welded anastomoses exhibited less peritracheal inflammatory reaction and showed visibly smoother luminal surfaces at 21 and 28 days post- operatively. Tracheal anastomosis using ICG dye enhanced fibrinogen combined with the near-infrared diode laser is a promising extension of the technology of laser tissue fusion and deserves further study.

  1. The value of antibody-coated bacteria in tracheal aspirates for the diagnosis of ventilator-associated pneumonia: a case-control study.

    Science.gov (United States)

    Ranzani, Otavio Tavares; Forte, Daniel Neves; Forte, Antonio Carlos; Mimica, Igor; Forte, Wilma Carvalho Neves

    2016-01-01

    Ventilator-associated pneumonia (VAP) is the leading type of hospital-acquired infection in ICU patients. The diagnosis of VAP is challenging, mostly due to limitations of the diagnostic methods available. The aim of this study was to determine whether antibody-coated bacteria (ACB) evaluation can improve the specificity of endotracheal aspirate (EA) culture in VAP diagnosis. We conducted a diagnostic case-control study, enrolling 45 patients undergoing mechanical ventilation. Samples of EA were obtained from patients with and without VAP (cases and controls, respectively), and we assessed the number of bacteria coated with FITC-conjugated monoclonal antibodies (IgA, IgM, or IgG) or an FITC-conjugated polyvalent antibody. Using immunofluorescence microscopy, we determined the proportion of ACB among a fixed number of 80 bacteria. The median proportions of ACB were significantly higher among the cases (n = 22) than among the controls (n = 23)-IgA (60.6% vs. 22.5%), IgM (42.5% vs. 12.5%), IgG (50.6% vs. 17.5%), and polyvalent (75.6% vs. 33.8%)-p 95,0% e > 93,3%, respectivamente. O número de BRA em amostras de AT foi maior nos casos que nos controles. Nossos achados indicam que a avaliação de BRA no AT é uma ferramenta promissora para aumentar a especificidade do diagnóstico de PAVM. A técnica pode ser custo-efetiva e, portanto, útil em locais com poucos recursos, com as vantagens de minimizar resultados falso-positivos e evitar o tratamento excessivo.

  2. A Prospective Observational Study of Technical Difficulty With GlideScope-Guided Tracheal Intubation in Children.

    Science.gov (United States)

    Zhang, Bin; Gurnaney, Harshad G; Stricker, Paul A; Galvez, Jorge A; Isserman, Rebecca S; Fiadjoe, John E

    2018-05-09

    The GlideScope Cobalt is one of the most commonly used videolaryngoscopes in pediatric anesthesia. Although visualization of the airway may be superior to direct laryngoscopy, users need to learn a new indirect way to insert the tracheal tube. Learning this indirect approach requires focused practice and instruction. Identifying the specific points during tube placement, during which clinicians struggle, would help with targeted education. We conducted this prospective observational study to determine the incidence and location of technical difficulties using the GlideScope, the success rates of various corrective maneuvers used, and the impact of technical difficulty on success rate. We conducted this observational study at our quaternary pediatric hospital between February 2014 and August 2014. We observed 200 GlideScope-guided intubations and documented key intubation-related outcomes. Inclusion criteria for patients were the number of advancement maneuvers required to intubate the trachea, the location where technical difficulty occurred, the types of maneuvers used to address difficulties, and the tracheal intubation success rate. We used a bias-corrected bootstrapping method with 300 replicates to determine the 95% confidence interval (CI) around the rate of difficulty with an intubation attempt. After excluding attempts by inexperienced clinicians, there were 225 attempts in 187 patients, 58% (131 of 225; bootstrap CI, 51.6%-64.6%]) of the attempts had technical difficulties. Technical difficulty was most likely to occur when inserting the tracheal tube between the plane of the arytenoid cartilages to just beyond the vocal cords: "zone 3." Clockwise rotation of the tube was the most common successful corrective maneuver in zone 3. The overall tracheal intubation success rate was 98% (CI, 95%-99%); however, the first attempt success rate was only 80% (CI, 74%-86%). Patients with technical difficulty had more attempts (median [interquartile range], 2 [1

  3. Controlled Thermal-Mechanical Processing of Tubes and Pipes for Enhanced Manufacturing and Performance

    Energy Technology Data Exchange (ETDEWEB)

    Kolarik, Robert V.

    2005-11-11

    The Alloy Steel Business of The Timken Company won an award for the controlled thermo-mechanical processing (CTMP) project and assembled a strong international public/private partnership to execute the project. The premise of the CTMP work was to combine Timken's product understanding with its process expertise and knowledge of metallurgical and deformation fundamentals developed during the project to build a predictive process design capability. The CTMP effort succeeded in delivering a pc-based capability in the tube optimization model, with a virtual pilot plant (VPP) feature to represent the desired tube making process to predict the resultant microstructure tailored for the desired application. Additional tasks included a system for direct, online measurement of grain size and demonstration of application of CTMP via robotically enhanced manufacturing.

  4. Results of investigation of spray controlled heat transfer crisis in tubes

    International Nuclear Information System (INIS)

    Sapankevich, A.P.; Kalinina, O.K.; Selivanov, Yu.F.

    1984-01-01

    Coefficient of liquid phase mass transfer is a determining parameter in tubes at crisis controlled with precipitating on heat surface a liquid phase carried in flow. To determine mass transfer coefficients in 4-14 MPa pressure range at 400-2000 kg/m 2 s mass velocities, special experiments were performed in experimental section consisting of two independently heated tubes in-series-connected along the flow. Heat transfer crisis was reached simultaneously in two sections which permitted to eliminate influence of liquid flowing on the wall in the controlsection. A part of heat removed due to forced convection was taken account of during calculation of mass transfer coefficient. Processing results are presented in the criterional form. Mean-square deviation with respect to massive obtained was amounted to 24% during calculation of the mass transfer coefficient and 20% during calculation of critical heat flux

  5. Vicks VapoRub induces mucin secretion, decreases ciliary beat frequency, and increases tracheal mucus transport in the ferret trachea.

    Science.gov (United States)

    Abanses, Juan Carlos; Arima, Shinobu; Rubin, Bruce K

    2009-01-01

    Vicks VapoRub (VVR) [Proctor and Gamble; Cincinnati, OH] is often used to relieve symptoms of chest congestion. We cared for a toddler in whom severe respiratory distress developed after VVR was applied directly under her nose. We hypothesized that VVR induced inflammation and adversely affected mucociliary function, and tested this hypothesis in an animal model of airway inflammation. [1] Trachea specimens excised from 15 healthy ferrets were incubated in culture plates lined with 200 mg of VVR, and the mucin secretion was compared to those from controls without VVR. Tracheal mucociliary transport velocity (MCTV) was measured by timing the movement of 4 microL of mucus across the trachea. Ciliary beat frequency (CBF) was measured using video microscopy. [2] Anesthetized and intubated ferrets inhaled a placebo or VVR that was placed at the proximal end of the endotracheal tube. We evaluated both healthy ferrets and animals in which we first induced tracheal inflammation with bacterial endotoxin (a lipopolysaccharide [LPS]). Mucin secretion was measured using an enzyme-linked lectin assay, and lung water was measured by wet/dry weight ratios. [1] Mucin secretion was increased by 63% over the controls in the VVR in vitro group (p < 0.01). CBF was decreased by 35% (p < 0.05) in the VVR group. [2] Neither LPS nor VVR increased lung water, but LPS decreased MCTV in both normal airways (31%) and VVR-exposed airways (30%; p = 0.03), and VVR increased MCTV by 34% in LPS-inflamed airways (p = 0.002). VVR stimulates mucin secretion and MCTV in the LPS-inflamed ferret airway. This set of findings is similar to the acute inflammatory stimulation observed with exposure to irritants, and may lead to mucus obstruction of small airways and increased nasal resistance.

  6. Avoidance versus use of neuromuscular blocking agents for improving conditions during tracheal intubation or direct laryngoscopy in adults and adolescents

    DEFF Research Database (Denmark)

    Lundstrøm, Lars Hyldborg; Duez, Christophe Hv; Nørskov, Anders Kehlet

    2017-01-01

    ) for adults and adolescents allocated to tracheal intubation with direct laryngoscopy. To look at various outcomes, conduct subgroup and sensitivity analyses, examine the role of bias, and apply trial sequential analysis (TSA) to examine the level of available evidence for this intervention. SEARCH METHODS......: We searched CENTRAL, MEDLINE, Embase, BIOSIS, International Web of Science, LILACS, advanced Google, CINAHL, and the following trial registries: Current Controlled Trials; ClinicalTrials.gov; and www.centerwatch.com, up to January 2017. We checked the reference lists of included trials and reviews...... the best conditions for tracheal intubation and may reduce the risk of upper airway discomfort or injury following tracheal intubation. Study results were characterized by indirectness, heterogeneity, and high or uncertain risk of bias concerning our primary outcome describing difficult tracheal intubation...

  7. Tracheal stenosis after treatment with metallic stent: a situation worse than the initial problem

    International Nuclear Information System (INIS)

    Barreto, Jaime; Mejia, Bibiana; Nino, Federico; Garavito, Carlos

    2008-01-01

    Stens are a tubular device for use in trachea, carina or main bronchus to provide a support and maintain the permeability of these structures. There are two groups: Metallic and Silicone stent. Either metallic and silicone stents has a special properties. Metallic stent are very attractive option due to relative easy in their placement. The accumulated experience in this therapy has allowed to recognize several complications to take into consideration mainly in patients with tracheal benign stenosis. FDA has recommended don't use metallic stents, covered and not covered in benign diseases. We report a case of a tracheal stenosis secondary to prolonged ortho tracheal intubation that required extensive interventions to control symptoms of central airway obstruction, between April and July of 2005.

  8. Management of a case of left tracheal sleeve pneumonectomy under cardiopulmonary bypass: Anesthesia perspectives

    Directory of Open Access Journals (Sweden)

    Aman Jyoti

    2014-01-01

    Full Text Available The lung tumors with carinal involvement are frequently managed with tracheal sleeve pneumonectomy and tracheobronchial anastomosis without use of cardiopulmonary bypass (CPB. Various modes of ventilation have been described during tracheal resection and anastomosis. Use of CPB during this period allows the procedure to be conducted in a more controlled way. We performed tracheal sleeve pneumonectomy for adenoid cystic carcinoma of left lung involving carina. The surgery was performed in two stages. In the first stage, left pneumonectomy was performed and in the second stage after 48 h, tracheobronchial resection and anastomosis was performed under CPB. Second stage was delayed to avoid excessive bleeding (due to heparinization from the extensive vascular raw area left after pneumonectomy. Meticulous peri-operative planning and optimal post-operative care helped in successful management of a complex case, which is associated with high morbidity and mortality.

  9. Viscoelastic Properties of Human Tracheal Tissues.

    Science.gov (United States)

    Safshekan, Farzaneh; Tafazzoli-Shadpour, Mohammad; Abdouss, Majid; Shadmehr, Mohammad B

    2017-01-01

    The physiological performance of trachea is highly dependent on its mechanical behavior, and therefore, the mechanical properties of its components. Mechanical characterization of trachea is key to succeed in new treatments such as tissue engineering, which requires the utilization of scaffolds which are mechanically compatible with the native human trachea. In this study, after isolating human trachea samples from brain-dead cases and proper storage, we assessed the viscoelastic properties of tracheal cartilage, smooth muscle, and connective tissue based on stress relaxation tests (at 5% and 10% strains for cartilage and 20%, 30%, and 40% for smooth muscle and connective tissue). After investigation of viscoelastic linearity, constitutive models including Prony series for linear viscoelasticity and quasi-linear viscoelastic, modified superposition, and Schapery models for nonlinear viscoelasticity were fitted to the experimental data to find the best model for each tissue. We also investigated the effect of age on the viscoelastic behavior of tracheal tissues. Based on the results, all three tissues exhibited a (nonsignificant) decrease in relaxation rate with increasing the strain, indicating viscoelastic nonlinearity which was most evident for cartilage and with the least effect for connective tissue. The three-term Prony model was selected for describing the linear viscoelasticity. Among different models, the modified superposition model was best able to capture the relaxation behavior of the three tracheal components. We observed a general (but not significant) stiffening of tracheal cartilage and connective tissue with aging. No change in the stress relaxation percentage with aging was observed. The results of this study may be useful in the design and fabrication of tracheal tissue engineering scaffolds.

  10. Metallic stent implantation in the treatment of malignant tracheal stenosis under general anaesthesia

    International Nuclear Information System (INIS)

    Bai Xuming; Jin Yong; Xie Hong; Cheng Long; Gu Xingshi; Chang Liuhui

    2012-01-01

    Objective: To evaluate the safety and feasibility of the tracheal stent implantation for treatment of malignant tracheal stenosis under general anaesthesia. Methods: Eighteen patients with malignant tracheal stenosis underwent preoperative 64-slice spiral CT scan and airway reconstruction. The stenotic sites were located in main tracheal trunk (5 patients), in right main bronchus (1 patient), in trachea and left main bronchus (4 patients), in trachea and right main bronchus (3 patients), in main tracheal trunk and bilateral main bronchus (5 patients). The degree of stenosis was rated 51% to 70% in 7 cases, 71% to 90% in 11 cases. All patients, 17 patients of ASA grade Ⅳ and 1 patient of grade Ⅲ, presented with severe dyspnea. Under general anaesthesia, implantation of metallic stent was performed through the sputum aspiration hole of the connecting tubing with DSA guidance. The NBP, ECG, RR, SaO 2 of the patients were recorded and compared with t test during the entire procedure. At the end of the procedure, relief of dyspnea, complications related to anesthesia and operation were recorded. Results: The success rate of stent placement was 18/18, and dyspnea was significantly relived in all patients. Slightly bloody sputum occurred in 7 cases. The stent was obstructed by sputum in 1 case,and the patient was treated with medication. There were no severe complications. The operative course were rated 11 to 9 in 17 cases, and 6 to 8 in 1 case. All 18 patients were cooperative during the procedure. Sixteen patients rated the procedure as very comfortable and 2 rated the procedure as comfortable. Respiratory rate (RR) and heart rate (HR) decreased in all patients after the operation [(37.1 ± 2.8)/min and (106.5 ± 14.2) bpm before the operation respectively, (18.6 ± 1.4)/min and (73.2 ± 7.6) bpm after the operation respectively], t=17.81 and 3.80, P<0.01. Pulse oxygen saturation (SaO 2 ) during the operation [(91.2 ± 1.8)%]increased [(76.3 ± 8.6 )% before the

  11. Tracheal Chondrosarcoma: Systematic Review of Tumor Characteristics, Diagnosis, and Treatment Outcomes with Case Report

    Directory of Open Access Journals (Sweden)

    Emily A. Kutzner

    2017-01-01

    Full Text Available To our knowledge this is the first systematic review of tracheal chondrosarcoma treatment outcomes. Management insights are thoroughly discussed. Men constitute 93.8% of cases, and most of these occur in the distal trachea. The most common symptom, dyspnea, occurs in virtually all patients. Extratracheal extension had occurred in 78.6% of patients. Definitive treatment with tracheal resection showed no recurrences in 10 patients with mean follow-up of 3.1 years. Adjuvant radiotherapy may be utilized for improving local control when open complete resection cannot be performed, but only after endoscopic excision of gross tumor.

  12. Design and fabrication of hafnium tube to control the power of the irradiation test fuel in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Lee, C. B.; Kim, Y. M.; Yang, Y. S.; Jung, Y. H

    2003-05-01

    For the irradiation test at HANARO, non-instrumentation capsule was manufactured and hafnium tube was used to control LHGR of HANARO. Hafnium tube can control the irradiation condition of HANARO similar to that of commercial reactor. Hafnium tube thickness was determined by the LHGR calculated at OR-4 irradiation hole to be installed the non-instrumented capsule. To fabricate the hafnium tube with hafnium plate, the fabrication method was determined by using the hafnium mechanical properties. And the tensile strength of hafnium was confirmed by tensile test. This report is confirmed the LHGR control at the OR-4 and the Hafnium fabrication for in used which the AFPCAP non-instrumented irradiation capsule.

  13. [The cause and efficacy of benign tracheal stenosis].

    Science.gov (United States)

    Su, Zhu-quan; Wei, Xiao-qun; Zhong, Chang-hao; Chen, Xiao-bo; Luo, Wei-zhan; Guo, Wen-liang; Wang, Ying-zhi; Li, Shi-yue

    2013-09-01

    To analysis the causes of benign tracheal stenosis and evaluate the curative effect of intraluminal bronchoscopic treatment. 158 patients with benign tracheal stenosis in our hospital from September 2005 to September 2012 were collected to retrospectively analysis the causes and clinic features of tracheal stenosis. Interventional treatments through bronchoscopy were used to treat the benign tracheal stenosis and the curative effects were evaluated. 158 cases of benign tracheal stenosis were recruited to our study, 69.6% of them were young and middle-aged. The main causes of benign tracheal stenosis were as follows: secondary to postintubation or tracheotomy in 61.4% (97/158), tuberculosis in 16% (26/158), benign tumor in 5.1% (8/158) and other 27 cases. 94.3% patients improved in symptoms with alleviation immediately after bronchoscopic treatment, the average tracheal diameter increased form (4.22 ± 2.06) mm to (10.16 ± 2.99) mm (t = 21.48, P benign tracheal stenosis were increasing year by year. The most common cause of benign tracheal stenosis was postintubation and tracheotomy. Interventional treatments through bronchoscopy is effective in treating benign tracheal stenosis, but repeated interventional procedures may be required to maintain the favorable long-term effects.

  14. Dealing with control rod guide tube support pin cracking in French PWRs

    International Nuclear Information System (INIS)

    Guicherd, L.

    1984-01-01

    Cracking and failure of control rod guide tube support pins has been encountered at a number of PWRs around the world. To deal with the problem, the French embarked on an extremely ambitious backfitting programme, involving the installation of replacement pins at all their operating 900MWe units. This highly successful programme, which will be completed in 1985, has been carried out with very low occupational doses and, in the last two years, has required no extensions to annual refuelling outage periods at the plants concerned. The French approach has involved a number of innovations, which should be of considerable interest to other PWR owners worldwide. (author)

  15. Device and process for controlling the shoot peening efficiency, of a steam generator tube inner surface

    International Nuclear Information System (INIS)

    Isnardon, G.; Jacquier, P.; Voisembert, S.

    1988-01-01

    This device comprises an outer envelope of tubular shape applied on the face of the tubular plate around one end of the tube to be peened. A tool comprising a nozzle for the projection of the peening particles is axially mounted in the outer envelope. The controlling device comprises at least one piezoelectric sensor arranged to be in contact with the wall of the outer envelope and measuring means for the electrical signal generated by the sensor. The projection nozzle is brought into the outer envelope at the level of the sensor after each peening operation and the electrical voltage of the signal produced by the sensor is measured [fr

  16. A content analysis of smoking fetish videos on YouTube: regulatory implications for tobacco control.

    Science.gov (United States)

    Kim, Kyongseok; Paek, Hye-Jin; Lynn, Jordan

    2010-03-01

    This study examined the prevalence, accessibility, and characteristics of eroticized smoking portrayal, also referred to as smoking fetish, on YouTube. The analysis of 200 smoking fetish videos revealed that the smoking fetish videos are prevalent and accessible to adolescents on the website. They featured explicit smoking behavior by sexy, young, and healthy females, with the content corresponding to PG-13 and R movie ratings. We discuss a potential impact of the prosmoking image on youth according to social cognitive theory, and implications for tobacco control.

  17. Demonstration of a Porous Tube Hydroponic System to Control Plant Moisture and Growth

    Science.gov (United States)

    Dreschel, T. W.; Hall, C. R.; Foster, T. E.

    2003-01-01

    Accurate remote detection of plant health indicators such as moisture, plant pigment concentrations, photosynthetic flux, and other biochemicals in canopies is a major goal in plant research. Influencing factors include complex interactions between wavelength dependent absorbing and scattering features from backgrounds as well as canopy biochemical and biophysical constituents. Accurately controlling these factors in outdoor field studies is difficult. Early testing of a porous tube plant culture system has indicated that plant biomass production, biomass partitioning, and leaf moisture of plants can be controlled by precisely managing the root water potential. Managing nutrient solution chemistry can also control plant pigments, biochemical concentrations, plant biomass production, and photosynthetic rates. A test bed was developed which utilized the porous tube technology with the intent of evaluating remote sensing systems, spectral analyses procedures, gas-exchange, and fluorescence measurements for their ability to detect small differences in plant water status. Spectral analysis was able to detect small differences in the mean leaf water content between the treatments. However these small differences were not detectable in the gas-exchange or fluorescence measurements.

  18. Experimental and numerical analysis of heat transfer phenomena in a sensor tube of a mass flow controller

    International Nuclear Information System (INIS)

    Jang, Seok Pil; Kim, Sung Jin; Choi, Do Hyung

    2000-01-01

    As a mass flow controller is widely used in many manufacturing processes for controlling a mass flow rate of gas with accuracy of 1%, several investigators have tried to describe the heat transfer phenomena in a sensor tube of an MFC. They suggested a few analytic solutions and numerical models based on simple assumptions, which are physically unrealistic. In the present work, the heat transfer phenomena in the sensor tube of the MFC are studied by using both experimental and numerical methods. The numerical model is introduced to estimate the temperature profile in the sensor tube as well as in the gas stream. In the numerical model, the conjugate heat transfer problem comprising the tube wall and the gas stream is analyzed to fully understand the heat transfer interaction between the sensor tube and the fluid stream using a single domain approach. This numerical model is further verified by experimental investigation. In order to describe the transport of heat energy in both the flow region and the sensor tube, the Nusselt number at the interface between the tube wall and the gas stream as well as heatlines is presented from the numerical solution

  19. Radiation response of perfused tracheal sections

    International Nuclear Information System (INIS)

    Ford, J.R.; Maslowski, A.J.; Braby, L.A.

    2003-01-01

    Full text: A model of respiratory tissue using a perfusion culture system is being developed. We are using this system to quantify the effects of normal tissue architecture and the interaction of epithelial cells with other cell types on radiation-induced bystander effects. Tracheal tissue taken from young adult male Fischer 344 rats is imbedded in a growth factor enriched agarose matrix. The chamber is designed to allow growth medium to periodically wash the epithelial surface of the tracheal lumen while maintaining the air-interface that is necessary for the normal differentiation of the epithelium. In preliminary experiments with rat trachea we have shown that a differentiated epithelial lining can be maintained for several days. Cells can be obtained for a number of different cell culture assays for endpoints such as survival and preneoplastic transformation after irradiation

  20. Simulated experimental research on flow field near control rod guide tubes

    International Nuclear Information System (INIS)

    Yu Ping'an; Shen Xiuzhong; Yang Guanyue; He Fangzheng; Gao Weiguo; Zhang Zhiyi; Tian Ji'an

    1997-01-01

    The paper presents the velocity measurement in the 1/4 scale transparent model of PWR pressure vessel upper plenum of 300 MW nuclear power plant by employing dynamic resistance strain foil velocity measurement technology and laser Doppler velocity measurement technology which have no effect on the flow field. In the experiment water is chosen as the fluid. As a result of the measurement the hydraulic load on the control rods is clarified and the experimental basis is provided for the analysis of whether the control rods are moving upward and downward freely and drop rapidly in emergency case by order. Meantime it also provides the experimental basis for the optical design of the control rod guide tubes and bundles

  1. Tracheal Constriction In A Growing Dog

    OpenAIRE

    DeArmond, Christina; Niimura del Barrio, Maria Chie; Rosati, Tomasso; McAllister, Hester; Ryan, John

    2017-01-01

    A six-month-old castrated male German Shepherd/Husky cross was presented for investigation of a progressive dyspnoea and regurgitation. A circumferential cervical wound had been identified and closed following debridement by the primary care veterinarian when the dog was three months old. There was an extraluminal tracheal compression on radiographs. Surgical exploration revealed a plastic band tied and embedded in the dorsal musculature of the neck. The band had been increasingly constrictin...

  2. Multi-region fuzzy logic controller with local PID controllers for U-tube steam generator in nuclear power plant

    Directory of Open Access Journals (Sweden)

    Puchalski Bartosz

    2015-12-01

    Full Text Available In the paper, analysis of multi-region fuzzy logic controller with local PID controllers for steam generator of pressurized water reactor (PWR working in wide range of thermal power changes is presented. The U-tube steam generator has a nonlinear dynamics depending on thermal power transferred from coolant of the primary loop of the PWR plant. Control of water level in the steam generator conducted by a traditional PID controller which is designed for nominal power level of the nuclear reactor operates insufficiently well in wide range of operational conditions, especially at the low thermal power level. Thus the steam generator is often controlled manually by operators. Incorrect water level in the steam generator may lead to accidental shutdown of the nuclear reactor and consequently financial losses. In the paper a comparison of proposed multi region fuzzy logic controller and traditional PID controllers designed only for nominal condition is presented. The gains of the local PID controllers have been derived by solving appropriate optimization tasks with the cost function in a form of integrated squared error (ISE criterion. In both cases, a model of steam generator which is readily available in literature was used for control algorithms synthesis purposes. The proposed multi-region fuzzy logic controller and traditional PID controller were subjected to broad-based simulation tests in rapid prototyping software - Matlab/Simulink. These tests proved the advantage of multi-region fuzzy logic controller with local PID controllers over its traditional counterpart.

  3. Recurred Post-intubation Tracheal Stenosis Treated with Bronchoscopic Cryotherapy

    Science.gov (United States)

    Jung, Ye-Ryung; Taek Jeong, Joon; Kyu Lee, Myoung; Kim, Sang-Ha; Joong Yong, Suk; Jeong Lee, Seok; Lee, Won-Yeon

    2016-01-01

    Post-intubation tracheal stenosis accounts for the greatest proportion of whole-cause tracheal stenosis. Treatment of post-intubation tracheal stenosis requires a multidisciplinary approach. Surgery or an endoscopic procedure can be used, depending on the type of stenosis. However, the efficacy of cryotherapy in post-intubation tracheal stenosis has not been validated. Here, we report a case of recurring post-intubation tracheal stenosis successfully treated with bronchoscopic cryotherapy that had previously been treated with surgery. In this case, cryotherapy was effective in treating web-like fibrous stenosis, without requiring more surgery. Cryotherapy can be considered as an alternative or primary treatment for post-intubation tracheal stenosis. PMID:27853078

  4. Successful conservative management of a rare complication of tracheostomy; extensive posterior tracheal false pouch.

    Science.gov (United States)

    Ha, Jennifer F; Ostwani, Waseem; Green, Glenn

    2016-11-01

    With the advent of improved neonatal and pediatric intensive care management, tracheostomy is increasingly performed in children requiring prolonged ventilation. Even though tracheostomy is generally a safe procedure, there remains mortality and morbidity associated with it. We report a rare complication of a tracheostomy tube resulting in extensive erosion and posterior tracheal false pouch secondary to a large tracheostomy tube and high positive end expiratory pressure in a 12-month-old infant. This was managed successfully with conservative treatment. A former 34-week premature infant was transferred to our pediatrics intensive care unit (PICU) with recurrent episodes of cardiopulmonary arrests due to suspected severe tracheobronchomalacia. The patient has bronchopulomonary dysplasia, severe restrictive lung disease and thoracic insufficiency from skeletal dysplasia requiring tracheostomy tube (TT) at two-month-old and mechanical ventilation. The 3.5 NEO TT was gradually upsized to a 5. The PEEP setting at transfer was 18cmH2O. The direct laryngoscopy and bronchoscopy showed moderate tracheomalacia at the innominate artery with a false pouch in the posterior tracheal wall that was 1.1cm below the tracheostomy stoma. A multi-disciplinary discussion including otolaryngology, PICU, Pulmonary Medicine, and Pediatric Surgery decided on conservative management. The false pouch healed and she was transferred back to referring PICU after a 46-day. Tracheal wall erosion resulting in a pouch formation is a rare complication, but it should be considered in patients with long term tracheostomy with difficulty ventilation and oxygenation with positional change. DLB is a useful tool in its diagnosis and conservative management can be successful. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. New insights into controlling tube-bundle fouling using alternative amines

    International Nuclear Information System (INIS)

    Turner, C.W.; Klimas, S.J.; Guzonas, D.A.; Frattini, P.L.; Fruzzetti, K.

    2002-01-01

    A volatile amine is added to the secondary heat-transport system of a nuclear power plant to reduce the rate of corrosion and corrosion product transport in the feedwater and to protect steam generator (SG) crevices and materials exposed to steam condensate. Volatility and base strength of the amine at the SG operating temperature are two important considerations when choosing the optimum amine (or mixture of amines) for corrosion control in the steam cycle. Atomic Energy of Canada Limited (AECL) and Electric Power Research Institute (EPRI) have been collaborating in an extensive investigation of the effectiveness of amines at controlling the rate of tube-bundle fouling under SG operating conditions. Tests have been performed using a radiotracing technique in a high-temperature fouling loop facility at Chalk River Laboratories operated by AECL. This investigation has provided new insights into the role played by the amine in determining the rate of tube-bundle fouling in the SG. These insights are being used by AECL and EPRI to develop criteria for the selection of an amine that has optimum properties for both corrosion control and deposit control in the secondary heat transport system. The investigation has found that the rate of tube-bundle fouling is strongly dependent upon the surface chemistry of the corrosion products. For example, the fouling rates of fully oxidized iron oxides, such as hematite and lepidocrocite, are at least an order of magnitude greater than the fouling rate of magnetite under identical operating conditions. The difference is related to the sign of the surface charge on the corrosion products at temperature. The choice of amine for pH-control also influences the fouling rate. This was originally thought to be a surface-charge effect as well, but recent tests have suggested that it is related to the role that the amine plays in governing the rate of deposit consolidation on the heat-transfer surface. Amines that promote a high rate of

  6. Computer control in nondestructive testing illustrated by an automatic ultrasonic tube inspection system

    International Nuclear Information System (INIS)

    Gundtoft, H.E.; Nielsen, N.

    1976-06-01

    In Risoe's automatic tube inspection system, data (more than half a million per tube) from ultrasonic dimension measurements and defect inspections are fed into a computer that simultaneously calculates and evaluates the results. (author)

  7. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial.

    Science.gov (United States)

    Mirmohammad-Sadeghi, Mohsen; Pourazari, Pejman; Akbari, Mojtaba

    2017-01-01

    Chest tubes are used in every case of coronary artery bypass grafting (CABG) to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group ( P = 0.001), but the trend of pain score between groups was not significantly different ( P = 0.097). The frequency of tamponade and atrial fibrillation (AF) were significantly lower in Jackson-Pratt drain group ( P drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  8. [Vocal cord paralysis associated with tracheal intubation: incidence, risk analysis, and classification of severity].

    Science.gov (United States)

    Kikura, Mutsuhito; Suzuki, Yuji; Itagaki, Taiga; Sato, Tsunehisa; Nishino, Junko

    2015-01-01

    Vocal cord paralysis after tracheal intubation is rare. It causes severe hoarseness and aspiration, and delays recovery and discharge. Arytenoid cartilage dislocation and recurrent nerve paralysis are main causes of vocal cord paralysis. Physical stimulation of the tracheal tube as well as patient and surgical characteristics also contribute. Vocal cord paralysis occurs in 1 (0.07%) of 1,500 general surgery patients and on the left side in 70% of cases. It is associated with surgery/anesthesia time (two-fold, 3-6 hours; 15-fold, over 6 hours), age (three-fold, over 50 years), and diabetes mellitus or hypertension (two-fold). Symptoms resolve in 2-3 months. In adult cardiovascular surgery, vocal cord paralysis occurs in 1 (0.7-2%) of 50-100 cardiac surgery patients and 1 (8.6-32%) of 3-10 thoracic aortic surgery patients. In pediatric cardiac surgery, vocal cord paralysis occurs in 1 (0.1-0.5%) of 200-1,000 patients. We classified the severity of vocal cord paralysis as I, severe hoarseness; II, aspiration or dysphagia; and III, bilateral vocal cord paralysis, aspiration pneumonia, or the need for tracheal re-intubation or tracheotomy. We discuss the importance of informed consent for the patient and family.

  9. Spallation Neutron Source Drift Tube Linac Resonance Control Cooling System Modeling

    CERN Document Server

    Tang, Johnny Y; Champion, Marianne M; Feschenko, Alexander; Gibson, Paul; Kiselev, Yuri; Kovalishin, A S; Kravchuk, Leonid V; Kvasha, Adolf; Schubert, James P

    2005-01-01

    The Resonance Control Cooling System (RCCS) for the warm linac of the Spallation Neutron Source was designed by Los Alamos National Laboratory. The primary design focus was on water cooling of individual component contributions. The sizing the RCCS water skid was accomplished by means of a specially created SINDA/FLUINT model tailored to these system requirements. A new model was developed in Matlab Simulink and incorporates actual operational values and control valve interactions. Included is the dependence of RF input power on system operation, cavity detuning values during transients, time delays that result from water flows through the heat exchanger, the dynamic process of water warm-up in the cooling system due to dissipated RF power on the cavity surface, differing contributions on the cavity detuning due to drift tube and wall heating, and a dynamic model of the heat exchanger with characteristics in close agreement to the real unit. Because of the Matlab Simulink model, investigation of a wide range ...

  10. Iterated non-linear model predictive control based on tubes and contractive constraints.

    Science.gov (United States)

    Murillo, M; Sánchez, G; Giovanini, L

    2016-05-01

    This paper presents a predictive control algorithm for non-linear systems based on successive linearizations of the non-linear dynamic around a given trajectory. A linear time varying model is obtained and the non-convex constrained optimization problem is transformed into a sequence of locally convex ones. The robustness of the proposed algorithm is addressed adding a convex contractive constraint. To account for linearization errors and to obtain more accurate results an inner iteration loop is added to the algorithm. A simple methodology to obtain an outer bounding-tube for state trajectories is also presented. The convergence of the iterative process and the stability of the closed-loop system are analyzed. The simulation results show the effectiveness of the proposed algorithm in controlling a quadcopter type unmanned aerial vehicle. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  11. A system identification approach to the characterization and control of a piezoelectric tube actuator

    International Nuclear Information System (INIS)

    Mohammadzaheri, Morteza; Grainger, Steven; Bazghaleh, Mohsen

    2013-01-01

    This paper addresses the sensorless control of piezoelectric tube actuators to avoid the expense and practical limits of displacement sensors in nanopositioning applications. Three electrical signals have traditionally been used to estimate displacement: the piezoelectric voltage, the voltage induced in sensing electrodes and the voltage across a sensing resistor. In this work, the piezoelectric voltage was employed to estimate displacement; the use of this signal does not necessitate drift removal like the sensing voltage, and its superiority over the induced voltage is shown in this paper. The piezoelectric voltage is the actuating signal, so a feedforward architecture based on an inverse model is used for sensorless control. Inspired by internal model control (IMC), a filter together with the inverted model of the system, derived using system identification techniques, was used as the feedforward controller. The fixed-slope-input effect is illustrated as a prominent source of control error in tracking triangular references, then an additional nonlinear control command is proposed to address this effect and improve the control performance. (paper)

  12. Risk factors for neural tube defects in Riyadh City, Saudi Arabia: Case-control study.

    Science.gov (United States)

    Salih, Mustafa A M; Murshid, Waleed R; Mohamed, Ashry Gad; Ignacio, Lena C; de Jesus, Julie E; Baabbad, Rubana; El Bushra, Hassan M

    2014-01-01

    Both genetic and non-genetic environmental factors are involved in the etiology of neural tube defects (NTD) which affect 0.5-2/1000 pregnancies worldwide. This study aimed to explore the risk factors for the development of NTD in Saudi population, and highlight identifiable and preventable causes. Similar studies are scarce in similar populations ofthe Arabian Peninsula and North Africa. This is an unmatched concurrent case-control study including NTD cases born at King Khalid University Hospital, Riyadh during a 4-year period (2002-2006). The case-control study included 25 cases and 125 controls (case: control ratio of 1:5). Years of formal education, employment, household environment (including availability of air conditioning) and rate of parental consanguinity did not differ between mothers of cases and controls. Significantly higher proportion of mothers of cases had history of stillbirth compared to control mothers (16% vs 4.1%, P=0.02). Also family history of hydrocephalus and congenital anomalies were more prevalent in cases than controls (P values=0.0000 and 0.003, respectively). There was significant protective effect of periconceptional folic acid consumption both prior to conception (OR 0.02, 95% CI 0.00-0.07) and during the first 6 weeks of conception (OR 0.13, 95% CI 0.04-0.39). Further research, including a larger cohort, is required to enable ascertainment of gene-nutrient and gene environment interactions associated with NTD in Saudi Arabia.

  13. The diversity of the pollen tube pathway in plants: towards an increasing control by the sporophyte

    Directory of Open Access Journals (Sweden)

    Jorge eLora

    2016-02-01

    Full Text Available Plants, unlike animals, alternate multicellular diploid and haploid generations in their life cycle. While this is widespread all along the plant kingdom, the size and autonomy of the diploid sporophyte and the haploid gametophyte generations vary along evolution. Vascular plants show an evolutionary trend towards a reduction of the gametophyte, reflected both in size and lifespan, together with an increasing dependence from the sporophyte. This has resulted in an overlooking of the importance of the gametophytic phase in the evolution of higher plants. This reliance on the sporophyte is most notorious along the pollen tube journey, where the male gametophytes have to travel a long way inside the sporophyte to reach the female gametophyte. Along evolution, there is a change in the scenery of the pollen tube pathway that favors pollen competition and selection. This trend, towards apparently making complicated what could be simple, appears to be related to an increasing control of the sporophyte over the gametophyte with implications for understanding plant evolution.

  14. Control and optimization of solute transport in a thin porous tube

    KAUST Repository

    Griffiths, I. M.

    2013-03-01

    Predicting the distribution of solutes or particles in flows within porous-walled tubes is essential to inform the design of devices that rely on cross-flow filtration, such as those used in water purification, irrigation devices, field-flow fractionation, and hollow-fibre bioreactors for tissue-engineering applications. Motivated by these applications, a radially averaged model for fluid and solute transport in a tube with thin porous walls is derived by developing the classical ideas of Taylor dispersion. The model includes solute diffusion and advection via both radial and axial flow components, and the advection, diffusion, and uptake coefficients in the averaged equation are explicitly derived. The effect of wall permeability, slip, and pressure differentials upon the dispersive solute behaviour are investigated. The model is used to explore the control of solute transport across the membrane walls via the membrane permeability, and a parametric expression for the permeability required to generate a given solute distribution is derived. The theory is applied to the specific example of a hollow-fibre membrane bioreactor, where a uniform delivery of nutrient across the membrane walls to the extra-capillary space is required to promote spatially uniform cell growth. © 2013 American Institute of Physics.

  15. Control of biofouling on titanium condenser tubes with the use of electroless copper plating

    International Nuclear Information System (INIS)

    Anandkumar, B.; George, R.P.; Kamachi Mudali, U.; Ramachandran, D.

    2015-01-01

    In sea water environments titanium condenser tubes face serious issues of biofouling and biomineralization. Electroless plating of nanocopper film is attempted inside the tubes for the control of biofilm formation. Using advanced techniques like AFM, SEM, and XPS, electroless copper plated flat Ti specimens were characterized. Examination of Cu coated Ti surfaces using AFM and SEM showed more reduction in the microroughness compared to anodized Ti surface. Cu 2p 3/2 peak in XPS spectral analysis showed the shift in binding energy inferring the reduction of the hydroxide to metallic copper. Tubular specimens were exposed to sea water up to three months and withdrawn at monthly intervals to evaluate antibacterial activity and long term stability of the coating. Total viable counts and epifluorescence microscopy analyses showed two orders decrease in bacterial counts on copper coated Ti specimens when compared to as polished control Ti specimens. Molecular biology techniques like DGGE and protein expression analysis system were done to get insight into the community diversity and copper tolerance of microorganisms. DGGE gel bands clearly showed the difference in the bacterial diversity inferring from the 16S rRNA gene fragments (V3 regions). Protein analysis showed distinct protein spots appearing in electroless copper coated Ti biofilm protein samples in addition to protein spots common to both the biofilms of Cu coated and as polished Ti. The results indicated copper accumulating proteins in copper resistant bacterial species of biofilm. Reduced microroughness of the surface and toxic copper ions resulted in good biofouling control even after three months exposure to sea water. (author)

  16. Effects of tracheal occlusion with retinoic acid administration on normal lung development.

    Science.gov (United States)

    Delabaere, Amélie; Marceau, Geoffroy; Coste, Karen; Blanchon, Loïc; Déchelotte, Pierre-Jean; Blanc, Pierre; Sapin, Vincent; Gallot, Denis

    2017-05-01

    Tracheal occlusion (TO) is an investigational therapy for severe congenital diaphragmatic hernia that decreases pulmonary hypoplasia, but sustained TO also induces deficient surfactant synthesis. Intramuscular maternal administration of retinoic acid (RA) in a surgical rabbit model of congenital diaphragmatic hernia showed a beneficial effect on lung maturation. We evaluated the potential of RA delivery into the trachea and studied the combined effects of TO and RA on normal lung development. Experiments were performed on normal rabbit fetuses. Liposomes and capric triglyceride (Miglyol ® ), alone and with RA, were administered in the trachea just before TO (d26). Lung morphology and surfactant production were studied at term (d30). Tracheal occlusion increased lung weight and enhanced alveolar development but increased apoptotic activity and decreased surfactant expression. Tracheal injection of RA improved surfactant production to levels of normal controls. We established the potential of liposome and Miglyol as RA vehicle for delivering this bioactive molecule in the fetal airways. Tracheal RA injection seems to oppose the effects of TO in fetuses with normal lungs. © 2017 John Wiley & Sons, Ltd. © 2017 John Wiley & Sons, Ltd.

  17. Tracheal morphology and collapse in COPD: Correlation with CT indices and pulmonary function test

    International Nuclear Information System (INIS)

    Lee, Hyun Joo; Seo, Joon Beom; Chae, Eun Jin; Kim, Namkug; Lee, Choong Wook; Oh, Yeon-Mok; Lee, Sang Do

    2011-01-01

    Objectives: To assess the tracheal morphologic changes using CT in COPD (chronic obstructive lung disease) patients and to assess correlation between them and PFT (pulmonary function test) and CT parameters. Materials and methods: Ninety-two healthy individuals and 115 patients with COPD who underwent volumetric inspiration/expiration CT scanning were included. The Lsag, Lcor, and the tLA were measured. The TI was defined as the ratio of Lcor/Lsag. The tracheal morphologic changes (tLA, TI, and collapsibility) were compared in healthy individuals and COPD. In COPD patients, correlation of the tracheal morphologic change with PFT and CT parameters was assessed. Results: The TIs in the COPD patients were significantly lower than those in the control group (0.80 ± 0.15 vs. 0.88 ± 0.11, Mean ± SD) (p 1 (r = 0.29, p = 1 /FVC (r = 0.26, p < 0.01), and the GOLD stage (r = −0.26, p < 0.01). TI showed significant correlation with EI on both inspiration and expiration CT (r = −0.19, p = 0.04 and r = −0.23, p = 0.02), MLD on expiration CT (r = 0.27, p < 0.01), CT–ATI (r = 0.34, p < 0.01), and with LV on expiration CT (r = −0.25, p < 0.01). Conclusion: Among the tracheal morphologic changes, the most significant change in COPD patients compared with that in the control group, was the TI. In COPD patients, the tracheal morphologic change showed clinically significant correlation with severity of emphysema and CT indices.

  18. Graphics and control of the guide tube assembly reinforcement manipulators at Sizewell 'A'

    International Nuclear Information System (INIS)

    Burden, C.

    1996-01-01

    A method was devised to reinforce the lower lug welds of the Guide Tube Assemblies (GTA's) at Sizewell 'A'. A six degree of freedom manipulator was designed to place a clamp around the lugs and tighten it. The manipulator was fitted with the three fixed cameras but required another surveillance manipulator positioned in an adjacent standpipe to provide additional views. The need to prepare two standpipes limited the rate at which reinforcements could be made. Therefore an articulated two arm camera manipulator, which could be used on the existing manipulator mast was designed and built. The two manipulators were driven from separate desks and were controlled by the same supervisory computer linked to online graphics. The camera arm joints were driven on preplanned routes using a single joystick because of the complex moves and tight spaces involved. A large number of GTA sites have now been reinforced including a dropped GTA which had to be raised to carry out clamping. (Author)

  19. Design and Development of a control system for the Drift Tube Chamber High Voltage Power Supply

    CERN Document Server

    Leon Vega, Luis Gerardo

    2017-01-01

    This paper contains information related to the design and development of a control and data acquisition manager implemented in WinCC, a Siemens SCADA system. The goal was to manage a CAEN HV (High Voltage) system for powering a Drift Tube (DT) chamber of the CMS experiment. Basically, this manager consists of two sections: a friendly user interface and powerful scripts to manage the back-end. It is in charge of adjusting the power supply settings to the correct values needed for the DT Chamber operations (ON, OFF, Standby), depending of the requirements of the operator, managing automatically all the transition process. Also, the manager is in charge of configuring the archiving process for acquiring data and providing the history of the system. It also implements the monitoring of the status of each connected channel, alerting in case it is needed.

  20. Airway Management in a Patient With Tracheal Disruption due to Penetrating Neck Trauma With Hollow Point Ammunition: A Case Report.

    Science.gov (United States)

    Johnson, Angela M; Hill, James L; Zagorski, Dave J; McClain, Joseph M; Maronian, Nicole C

    2018-05-01

    Rapid sequence induction and intubation was performed for a patient in respiratory distress after a gunshot wound to the neck. Resistance was noted distal to vocal cords. With a bronchoscope unavailable, the endotracheal tube was advanced with a corkscrew maneuver. Subcutaneous emphysema had developed. The endotracheal tube was advanced into the right mainstem with adequate ventilation. Imaging illustrated tracheoesophageal injury. The patient was emergently explored. An intraluminal bullet was removed, lateral wall tracheal defect was repaired, and a tracheostomy was placed. The intubating provider should secure the airway by the method they are most comfortable, have high suspicion of airway injury, and prepare to manage airway disruption.

  1. Inositol for the prevention of neural tube defects: a pilot randomised controlled trial.

    Science.gov (United States)

    Greene, Nicholas D E; Leung, Kit-Yi; Gay, Victoria; Burren, Katie; Mills, Kevin; Chitty, Lyn S; Copp, Andrew J

    2016-03-28

    Although peri-conceptional folic acid (FA) supplementation can prevent a proportion of neural tube defects (NTD), there is increasing evidence that many NTD are FA non-responsive. The vitamin-like molecule inositol may offer a novel approach to preventing FA-non-responsive NTD. Inositol prevented NTD in a genetic mouse model, and was well tolerated by women in a small study of NTD recurrence. In the present study, we report the Prevention of Neural Tube Defects by Inositol (PONTI) pilot study designed to gain further experience of inositol usage in human pregnancy as a preliminary trial to a future large-scale controlled trial to evaluate efficacy of inositol in NTD prevention. Study subjects were UK women with a previous NTD pregnancy who planned to become pregnant again. Of 117 women who made contact, ninety-nine proved eligible and forty-seven agreed to be randomised (double-blind) to peri-conceptional supplementation with inositol plus FA or placebo plus FA. In total, thirty-three randomised pregnancies produced one NTD recurrence in the placebo plus FA group (n 19) and no recurrences in the inositol plus FA group (n 14). Of fifty-two women who declined randomisation, the peri-conceptional supplementation regimen and outcomes of twenty-two further pregnancies were documented. Two NTD recurred, both in women who took only FA in their next pregnancy. No adverse pregnancy events were associated with inositol supplementation. The findings of the PONTI pilot study encourage a large-scale controlled trial of inositol for NTD prevention, but indicate the need for a careful study design in view of the unwillingness of many high-risk women to be randomised.

  2. Self-propelled in-tube shuttle and control system for automated measurements of magnetic field alignment

    International Nuclear Information System (INIS)

    Boroski, W.N.; Nicol, T.H.; Pidcoe, S.V.

    1990-03-01

    A magnetic field alignment gauge is used to measure the field angle as a function of axial position in each of the magnets for the Superconducting Super Collider (SSC). Present measurements are made by manually pushing the through the magnet bore tube and stopping at intervals to record field measurements. Gauge location is controlled through graduation marks and alignment pins on the push rods. Field measurements are recorded on a logging multimeter with tape output. Described is a computerized control system being developed to replace the manual procedure for field alignment measurements. The automated system employs a pneumatic walking device to move the measurement gauge through the bore tube. Movement of the device, called the Self-Propelled In-Tube Shuttle (SPITS), is accomplished through an integral, gas driven, double-acting cylinder. The motion of the SPITS is transferred to the bore tube by means of a pair of controlled, retractable support feet. Control of the SPITS is accomplished through an RS-422 interface from an IBM-compatible computer to a series of solenoid-actuated air valves. Direction of SPITS travel is determined by the air-valve sequence, and is managed through the control software. Precise axial position of the gauge within the magnet is returned to the control system through an optically-encoded digital position transducer attached to the shuttle. Discussed is the performance of the transport device and control system during preliminary testing of the first prototype shuttle. 1 ref., 7 figs

  3. Endotracheal tube cuff pressure monitoring during neurosurgery - Manual vs. automatic method

    Directory of Open Access Journals (Sweden)

    Mukul Kumar Jain

    2011-01-01

    Full Text Available Background: Inflation and assessment of the endotracheal tube cuff pressure is often not appreciated as a critical aspect of endotracheal intubation. Appropriate endotracheal tube cuff pressure, endotracheal intubation seals the airway to prevent aspiration and provides for positive-pressure ventilation without air leak. Materials and Methods: Correlations between manual methods of assessing the pressure by an experienced anesthesiologists and assessment with maintenance of the pressure within the normal range by the automated pressure controller device were studied in 100 patients divided into two groups. In Group M, endotracheal tube cuff was inflated manually by a trained anesthesiologist and checked for its pressure hourly by cuff pressure monitor till the end of surgery. In Group C, endotracheal tube cuff was inflated by automated cuff pressure controller and pressure was maintained at 25-cm H 2 O throughout the surgeries. Repeated measure ANOVA was applied. Results: Repeated measure ANOVA results showed that average of endotracheal tube cuff pressure of 50 patients taken at seven different points is significantly different (F-value: 171.102, P-value: 0.000. Bonferroni correction test shows that average of endotracheal tube cuff pressure in all six groups are significantly different from constant group (P = 0.000. No case of laryngomalacia, tracheomalacia, tracheal stenosis, tracheoesophageal fistula or aspiration pneumonitis was observed. Conclusions: Endotracheal tube cuff pressure was significantly high when endotracheal tube cuff was inflated manually. The known complications of high endotracheal tube cuff pressure can be avoided if the cuff pressure controller device is used and manual methods cannot be relied upon for keeping the pressure within the recommended levels.

  4. Bronchoscopic Treatment in the Management of Benign Tracheal Stenosis: Choices for Simple and Complex Tracheal Stenosis.

    Science.gov (United States)

    Dalar, Levent; Karasulu, Levent; Abul, Yasin; Özdemir, Cengiz; Sökücü, Sinem Nedime; Tarhan, Merve; Altin, Sedat

    2016-04-01

    Bronchoscopic treatment is 1 of the treatment choices for both palliative and definitive treatment of benign tracheal stenosis. There is no consensus on the management of these patients, however, especially patients having complex stenoses. The aim of the present study was to assess, in the largest group of patients with complex stenoses yet reported, which types of tracheal stenosis are amenable to optimal management by bronchoscopic treatment. The present study was a retrospective cohort study including 132 consecutive patients with benign tracheal stenoses diagnosed between August 2005 and January 2013. The mean age of the study population was 52 ± 18 years; 62 (47%) were women and 70 (53%) were men. Their lesions were classified as simple and complex stenoses. Simple stenoses (n = 6) were treated with 12 rigid and flexible bronchoscopic procedures (mean of 2 per patient); 5 stents were placed. The total success rate was 100%. Among the 124 complex stenoses, 4 were treated directly with surgical intervention. In total, 481 rigid and 487 flexible bronchoscopic procedures were performed in these patients. In this group, the success rate was 69.8%. From the present study, we propose that after accurate classification, interventional bronchoscopic management may have an important role in the treatment of benign tracheal stenosis. Bronchoscopic treatment should be considered as first-line therapy for simple stenoses, whereas complex stenoses need a multidisciplinary approach and often require surgical intervention. However, bronchoscopic treatment may be a valid conservative approach in the management of patients with complex tracheal stenosis who are not eligible for operative treatment. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Synchrotron imaging of the grasshopper tracheal system: morphological and physiological components of tracheal hypermetry

    International Nuclear Information System (INIS)

    Greenlee, K.J.; Henry, J.R.; Kirkton, S.D.; Westneat, M.W.; Fezzaa, K.; Lee, W.; Harrison, J.F.

    2009-01-01

    As grasshoppers increase in size during ontogeny, they have mass specifically greater whole body tracheal and tidal volumes and ventilation than predicted by an isometric relationship with body mass and body volume. However, the morphological and physiological bases to this respiratory hypermetry are unknown. In this study, we use synchrotron imaging to demonstrate that tracheal hypermetry in developing grasshoppers (Schistocerca americana) is due to increases in air sacs and tracheae and occurs in all three body segments, providing evidence against the hypothesis that hypermetry is due to gaining flight ability. We also assessed the scaling of air sac structure and function by assessing volume changes of focal abdominal air sacs. Ventilatory frequencies increased in larger animals during hypoxia (5% O 2 ) but did not scale in normoxia. For grasshoppers in normoxia, inflated and deflated air sac volumes and ventilation scaled hypermetrically. During hypoxia (5% O 2 ), many grasshoppers compressed air sacs nearly completely regardless of body size, and air sac volumes scaled isometrically. Together, these results demonstrate that whole body tracheal hypermetry and enhanced ventilation in larger/older grasshoppers are primarily due to proportionally larger air sacs and higher ventilation frequencies in larger animals during hypoxia. Prior studies showed reduced whole body tracheal volumes and tidal volume in late-stage grasshoppers, suggesting that tissue growth compresses air sacs. In contrast, we found that inflated volumes, percent volume changes, and ventilation were identical in abdominal air sacs of late-stage fifth instar and early-stage animals, suggesting that decreasing volume of the tracheal system later in the instar occurs in other body regions that have harder exoskeleton.

  6. Synchrotron imaging of the grasshopper tracheal system : morphological and physiological components of tracheal hypermetry.

    Energy Technology Data Exchange (ETDEWEB)

    Greenlee, K. J.; Henry, J. R.; Kirkton, S. D.; Westneat, M. W.; Fezzaa, K.; Lee, W.; Harrison, J. F.; North Dakota State Univ.; Arizona State Univ.; Union Coll.; Field Museum of Natural History

    2009-11-01

    As grasshoppers increase in size during ontogeny, they have mass specifically greater whole body tracheal and tidal volumes and ventilation than predicted by an isometric relationship with body mass and body volume. However, the morphological and physiological bases to this respiratory hypermetry are unknown. In this study, we use synchrotron imaging to demonstrate that tracheal hypermetry in developing grasshoppers (Schistocerca americana) is due to increases in air sacs and tracheae and occurs in all three body segments, providing evidence against the hypothesis that hypermetry is due to gaining flight ability. We also assessed the scaling of air sac structure and function by assessing volume changes of focal abdominal air sacs. Ventilatory frequencies increased in larger animals during hypoxia (5% O{sub 2}) but did not scale in normoxia. For grasshoppers in normoxia, inflated and deflated air sac volumes and ventilation scaled hypermetrically. During hypoxia (5% O{sub 2}), many grasshoppers compressed air sacs nearly completely regardless of body size, and air sac volumes scaled isometrically. Together, these results demonstrate that whole body tracheal hypermetry and enhanced ventilation in larger/older grasshoppers are primarily due to proportionally larger air sacs and higher ventilation frequencies in larger animals during hypoxia. Prior studies showed reduced whole body tracheal volumes and tidal volume in late-stage grasshoppers, suggesting that tissue growth compresses air sacs. In contrast, we found that inflated volumes, percent volume changes, and ventilation were identical in abdominal air sacs of late-stage fifth instar and early-stage animals, suggesting that decreasing volume of the tracheal system later in the instar occurs in other body regions that have harder exoskeleton.

  7. Welded tracheal stent removal in a child under cardiopulmonary bypass.

    Science.gov (United States)

    Kao, S C; Chang, W K; Pong, M W; Cheng, K W; Chan, K H; Tsai, S K

    2003-08-01

    Metallic tracheal stents have been used in the treatment of paediatric tracheomalacia for more than a decade. We describe a case in which critical airway obstruction occurred during removal of a welded tracheal stent using a rigid bronchoscope under general anaesthesia. Life-saving cardiopulmonary bypass was instituted urgently, and the welded stent was then removed successfully by directly opening the trachea.

  8. Tracheal schwannoma: Completely resected with therapeutic bronchoscopic techniques

    Directory of Open Access Journals (Sweden)

    Barney Thomas Jesudason Isaac

    2015-01-01

    Full Text Available Tracheal schwannomas are rare benign tumors of the trachea. There are only a few reported cases in the literature. Surgeons have generally resected these tumors, whereas bronchoscopists have attempted to remove them bronchoscopically. We report a case of tracheal schwannoma which was completely resected using bronchoscopic techniques.

  9. Homologous tracheal transplantation with grafts previously exposed to high doses of gamma radiation in dogs without immunosuppressive agents

    International Nuclear Information System (INIS)

    Yokomise, Hiroyasu; Inui, Kenji; Kure, Toshio; Wada, Hiromi; Itomi, Shigeki

    1993-01-01

    The study was designed to determine whether previous high doses irradiation of gamma radiation would contribute to tracheal transplantation with no use of immunosuppressive agents. Twenty mongrel dogs were used as experimental animals. Five rings of thoracic tracheas, which were extracted from recipients, were exposed to 20000, 50000, or 100000 cGy in each 5 dogs. Five other non-irradiated dogs served as controls. Irradiated tracheal grafts were transplanted and covered with pedicled omentum. After transplantation, no immunosuppressive agents were given to dogs. All dogs in the control group died of tracheal stenosis due to graft-host rejection within one month. All but one long-term survivor died of tracheal stenosis, as well, in both the 20000 cGy and 50000 cGy groups. In the 100000 cGy group, grafts became viable in 4 dogs, and three of these survived one year or more. In conclusion, previous irradiation with high doses of 100000 cGy allowed homologous tracheal transplantation even when no immunosuppressive agents are given. (N.K.)

  10. Tracheobronchial Amyloidosis Mimicking Tracheal Tumor

    Directory of Open Access Journals (Sweden)

    Elif Tanrıverdi

    2016-01-01

    Full Text Available Tracheobronchial amyloidosis is a rare presentation and accounts for about 1% of benign tumors in this area. The diagnosis of disease is delayed due to nonspecific pulmonary symptoms. Therapeutic approaches are required to control progressive pulmonary symptoms for most of the patients. Herein, we report a case of a 68-year-old man admitted with progressive dyspnea to our institution for further evaluation and management. He was initially diagnosed with and underwent management for bronchial asthma for two years but had persistent symptoms despite optimal medical therapy. Pulmonary computed tomography scan revealed severe endotracheal stenosis. Bronchoscopy was performed and showed endotracheal mass obstructing 70% of the distal trachea and mimicking a neoplastic lesion. The mass was successfully resected by mechanical resection, argon plasma coagulation (APC, and Nd-YAG laser during rigid bronchoscopy. Biopsy materials showed deposits of amorphous material by hematoxylin and eosin staining and these deposits were selectively stained with Congo Red. Although this is a rare clinical condition, this case indicated that carrying out a bronchoscopy in any patient complaining of atypical bronchial symptoms or with uncontrolled asthma is very important.

  11. What's in a name? Expiratory tracheal narrowing in adults explained

    International Nuclear Information System (INIS)

    Leong, P.; Bardin, P.G.; Lau, K.K.

    2013-01-01

    Tracheomalacia, tracheobronchomalacia, and excessive dynamic airway collapse are all terms used to describe tracheal narrowing in expiration. The first two describe luminal reduction from cartilage softening and the latter refers to luminal reduction from exaggerated posterior membrane movement. Expiratory tracheal narrowing is a frequent occurrence that can cause symptoms of airway obstruction, such as dyspnoea, wheeze, and exercise intolerance. The accurate diagnosis and quantification of expiratory tracheal narrowing has important aetiological, therapeutic, and prognostic implications. The reference standard for diagnosis has traditionally been bronchoscopy; however, this method has significant limitations. Expiratory tracheal disorders are readily detected by four-dimensional dynamic volume multidetector computed tomography (4D-CT), an emerging, non-invasive method that will potentially enable detection and quantification of these conditions. This review discusses the morphological forms of expiratory tracheal narrowing and demonstrates the utility of 4D-CT in the diagnosis, quantification, and treatment of these important conditions

  12. Cellular distribution and function of ion channels involved in transport processes in rat tracheal epithelium.

    Science.gov (United States)

    Hahn, Anne; Faulhaber, Johannes; Srisawang, Lalita; Stortz, Andreas; Salomon, Johanna J; Mall, Marcus A; Frings, Stephan; Möhrlen, Frank

    2017-06-01

    Transport of water and electrolytes in airway epithelia involves chloride-selective ion channels, which are controlled either by cytosolic Ca 2+ or by cAMP The contributions of the two pathways to chloride transport differ among vertebrate species. Because rats are becoming more important as animal model for cystic fibrosis, we have examined how Ca 2+ - dependent and cAMP- dependent Cl - secretion is organized in the rat tracheal epithelium. We examined the expression of the Ca 2+ -gated Cl - channel anoctamin 1 (ANO1), the cystic fibrosis transmembrane conductance regulator (CFTR) Cl - channel, the epithelial Na + channel ENaC, and the water channel aquaporin 5 (AQP5) in rat tracheal epithelium. The contribution of ANO1 channels to nucleotide-stimulated Cl - secretion was determined using the channel blocker Ani9 in short-circuit current recordings obtained from primary cultures of rat tracheal epithelial cells in Ussing chambers. We found that ANO1, CFTR and AQP5 proteins were expressed in nonciliated cells of the tracheal epithelium, whereas ENaC was expressed in ciliated cells. Among nonciliated cells, ANO1 occurred together with CFTR and Muc5b and, in addition, in a different cell type without CFTR and Muc5b. Bioelectrical studies with the ANO1-blocker Ani9 indicated that ANO1 mediated the secretory response to the nucleotide uridine-5'-triphosphate. Our data demonstrate that, in rat tracheal epithelium, Cl - secretion and Na + absorption are routed through different cell types, and that ANO1 channels form the molecular basis of Ca 2+ -dependent Cl - secretion in this tissue. These characteristic features of Cl - -dependent secretion reveal similarities and distinct differences to secretory processes in human airways. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  13. Tracheal resections and anastomosis for benign tracheal stricture. A seven-year experience in a single tertiary institute

    Directory of Open Access Journals (Sweden)

    Ahmed Mostafa

    2017-09-01

    Conclusions: TRA proved to be a safe and reliable solution for post-intubation tracheal stenosis. This procedure should be considered first in developing countries where there is frequent rush for tracheostomies and tracheal stenting. Quality of life improved dramatically following this definitive surgery.

  14. Tracheal anastomosis with the diode laser and fibrin tissue adhesive: an in vitro and in vivo investigation.

    Science.gov (United States)

    Gleich, L L; Wang, Z; Pankratov, M M; Aretz, H T; Shapshay, S M

    1995-05-01

    Absorbable sutures have been advocated for tracheal anastomosis to reduce fibrosis and foreign body reaction leading to recurrent stenosis. Fibrin tissue adhesive (FTA) and diode laser welding with indocyanine green-dyed fibrinogen were evaluated in tracheal anastomosis to reduce the number of sutures and to improve healing. In vitro studies demonstrated strong anastomoses with a combination of laser welding and FTA with minimal tissue damage. In a controlled in vivo study, circumferential resections of canine tracheas were repaired with laser welding and FTA augmented with a few stay sutures. These anastomoses had less fibrosis and tissue damage than anastomoses in control animals repaired with sutures alone. This study supports investigation of laser welding and FTA in human beings for tracheal anastomosis and other procedures in which suturing may be difficult.

  15. Tracheal transplantation for carinal reconstruction in dogs.

    Science.gov (United States)

    Kawahara, K; Inutsuka, K; Hiratsuka, M; Makihata, S; Okabayashi, K; Shiraishi, T; Shirakusa, T

    1998-09-01

    Experimental carinal allotransplantation has been performed with tracheocarinal Y-shaped allografts in dogs. In this study we tried canine carinal reconstruction with cylindrical allografts. Carinal reconstruction was performed with allotransplantation of cylindrical trachea in dogs, and graft healing was evaluated by bronchoscopic observation, mucosal blood flow measurement, and histologic examination. A section of the recipient carina containing five tracheal rings and two main stem bronchi was removed, and a donor trachea seven rings long was inserted between the recipient trachea and the left main stem bronchus; then side-to-end anastomosis was performed between the graft midportion and recipient right main stem bronchus (new carina). The grafts were wrapped with pedicled omentum. Fresh grafts were transplanted into one group of dogs (n=8 ), and grafts cryopreserved for 1 week were transplanted into another group (n=7). No anastomotic leakage occurred in any dog. Excellent healing of grafts and graft anastomoses was observed by fiberoptic bronchoscopy in six dogs (75%) in the fresh graft group and in four dogs (57%) in the cryopreserved graft group. The mucosal blood flow in the new carina decreased remarkably and, although it recovered, mucosal blood flow remained under the preoperative level on day 28 after the operation. Cylindrical tracheal allotransplantation is useful for carinal reconstruction, and the method of side-to-end anastomosis between the donor trachea and recipient bronchus is a feasible and accessible procedure in dogs.

  16. Open Tracheostomy after Aborted Percutaneous Approach due to Tracheoscopy Revealing Occult Tracheal Wall Ulcer

    Directory of Open Access Journals (Sweden)

    John Schweiger

    2013-01-01

    Full Text Available Tracheostomy is a common procedure for intensive care patients requiring prolonged mechanical ventilation. In this case report, we describe a 78-year-old female patient admitted for an aneurysm of the cerebral anterior communicating artery. Following immediate endovascular coiling, she remained ventilated and was transferred to the neurological intensive care unit. On postoperative day ten, a percutaneous tracheostomy (PCT was requested; however, a large ulcer or possible tracheoesophageal fistula was identified on the posterior tracheal wall following bronchoscopic assessment of the trachea. Therefore, the requested PCT procedure was aborted. An open tracheostomy in the operating room was completed; however, due to the position and depth of the ulcer, a reinforced endotracheal tube (ETT was placed via the tracheostomy. Four days later, the reinforced ETT was replaced with a Shiley distal extended tracheostomy tube to bypass the ulceration. Careful inspection and evaluation of the tracheostomy site before PCT prevented a potentially life-threatening issue in our patient.

  17. Fabrication of a pressurized water reactor fuel element prototype with Zy-control rod guide tubes

    International Nuclear Information System (INIS)

    Bezold, H.; Romeiser, H.J.

    1978-10-01

    A prototype fuel assembly with zircaloy guide was fabricated by mass production methods. The fastening of the Inconel spacer grids to the guide tubes and the transition joint for fixing the tubes to the stainless stell upper end-fitting of the assembly were investigated. Tools and welding devices were developed for the construction of the skeleton. (orig.) [de

  18. Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers

    International Nuclear Information System (INIS)

    Kalender, W.A.; Wolf, H.; Suess, C.; Gies, M.; Greess, H.; Bautz, W.A.

    1999-01-01

    We investigated approaches to reducing the dose in CT without impairing image quality. Dose can be reduced for non-circular object cross-sections without a significant increase in noise if X-ray tube current is reduced at angular tube positions where the X-ray attenuation by the patients is small. We investigated different schemes of current modulation during tube rotation by simulation and phantom measurements. Both pre-programmed sinusoidal modulation functions and attenuation-based on-line control of the tube current were evaluated. All relevant scan parameters were varied, including constraints such as the maximum modulation amplitude. A circular, an elliptical and two oval water phantoms were used. Results were validated on six cadavers. Dose reduction of 10-45 % was obtained both in simulations and in measurements for the different non-circular phantom geometries and current modulation algorithms without an increase in pixel noise values. On-line attenuation-based control yielded higher reductions than modulation by a sinusoidal curve. The maximal dose reduction predicted by simulations could not be achieved due to limits in the modulation amplitude. In cadaver studies, a reduction of typically 20-40 % was achieved for the body and about 10 % for the head. Variations of our technique are possible; a slight increase in nominal tube current for high-attenuation projections combined with attenuation-based current modulation still yields significant dose reduction, but also a reduction in the structured noise that may obscure diagnostic details. We conclude that a significant reduction in dose can be achieved by tube current modulation without compromising image quality. Attenuation-based on-line control and a modulation amplitude of at least 90 % should be employed. (orig.)

  19. Time domain models for damping-controlled fluidelastic instability forces in multi-span tubes with loose supports

    International Nuclear Information System (INIS)

    Hassan, M.A.; Rogers, R.J.; Gerber, A.G.

    2009-01-01

    This paper presents simulations of a loosely supported multi-span tube subjected to turbulence and fluidelastic instability forces. Several time-domain fluid force models simulating the damping controlled fluidelastic instability mechanism in tube arrays have been presented. These models include the negative damping model based on the Connors equation, fluid force coefficient-based models (Chen and Tanaka and Takahara), and two semi-analytical models (Price and Paidoussis; and Lever and Weaver) were implemented in an in-house finite code. Time domain modeling challenges for each of these theories were discussed. The implemented models were validated against available experimental data. The linear simulations showed that the Connors-equation based model exhibits the most conservative prediction of the critical flow velocity when the recommended design values for the Connors equation were used. The models were then utilized to simulate the nonlinear response of a three-span cantilever tube in a square lattice bar support subjected to air crossflow. The tube was subjected to a single-phase flow passing over one of the tube's spans. For each of these models the flow velocity and the support clearance were varied. Special attention was paid to the tube/support interaction parameters that affect wear, such as impact forces, contact ratio, and normal work rate. As the prediction of the linear threshold varies depending on the utilized model, the nonlinear response also differs. The investigated models exhibit similar response characteristics for the impact force, tip lift response, and work rate. Simulation results show that the Connors-based model underestimates the response and the tube/support interaction parameters for the loose support case. (author)

  20. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Mohsen Mirmohammad-Sadeghi

    2017-01-01

    Full Text Available Background: Chest tubes are used in every case of coronary artery bypass grafting (CABG to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. Materials and Methods: This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. Results: The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group (P = 0.001, but the trend of pain score between groups was not significantly different (P = 0.097. The frequency of tamponade and atrial fibrillation (AF were significantly lower in Jackson-Pratt drain group (P < 0.05. Conclusion: The Jackson-Pratt drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  1. Temperature control of thermal-gas-dynamical installation in cleaning oil-well tubes

    Science.gov (United States)

    Penner, V. A.; Martemyanov, D. B.; Pshenichnikova, V. V.

    2017-08-01

    The article provides the study results of cleaning oil-well tubes, the oil-well tube failure reasons for service by their types have been considered. The chemical method of cleaning oil-well tubes as the least expensive has been reviewed when acid solution moves to the interptube space mixing up with oil and liquidates paraffin and pitches deposits on the internal pipe surface. Except the chemical method of pipes cleaning the mechanical one was considered as well. Also the disadvantages -such as the low productivity of cleaning and design complexity- of this deposits removal method on the internal oil-well tube surface have been considered. An effective method for cleaning oil-well tubing from paraffin and pitches by the thermodynamic plant based on the aircraft engine has been introduced for the first time. The temperature distribution graph in the gas stream at the engine output has been given.

  2. [Nasogastric tube feeding in bulimia. Controlled study with follow-up at 3 months].

    Science.gov (United States)

    Rigaud, Daniel; Brayer, Véronique; Biton-Jélic, Violaine; Païs, Vanessa; Pennacchio, Hélène; Brun, Jean-Marcel

    2007-10-01

    Few effective treatments are available for severe forms of bulimia nervosa, which are accompanied by malnutrition, anxiety, and depressive mood. We previously showed in an open study that nasogastric tube feeding (TF) reduced binges and purging in patients with anorexia nervosa. This prospective randomized trial compared bulimia patients in two treatment groups: one group received TF at home, together with psychotherapy, nutritional counseling and a support group while the control group received only psychotherapy, nutritional counseling, and a support group. Patients in the first group underwent TF for 8 weeks (exclusively for 10 days and associated with meals thereafter). Assessment was based on clinical examination, laboratory results, and a variety of questionnaires (our in-house instrument for measuring binge and vomiting episodes, eating disorder inventory, Beck's depression inventory and the Hamilton rating scale for anxiety), all performed at the onset of treatment and at 8 days, 8 weeks (i.e., the end of TF), and 3 months after treatment began. Binges and vomiting disappeared faster and more frequently in TF patients than in the control group: 65% versus 29% (pbulimia nervosa, reducing the number of binge and vomiting episodes and improving nutritional status and mood.

  3. Water-filled training tubes increase core muscle activation and somatosensory control of balance during squat.

    Science.gov (United States)

    Ditroilo, Massimiliano; O'Sullivan, Rory; Harnan, Brian; Crossey, Aislinn; Gillmor, Beth; Dardis, William; Grainger, Adam

    2018-09-01

    This study examined trunk muscle activation, balance and proprioception while squatting with a water-filled training tube (WT) and a traditional barbell (BB), with either closed (CE) or open eyes (OE). Eighteen male elite Gaelic footballers performed an isometric squat under the following conditions: BB-OE, BB-CE, WT-OE and WT-CE. The activity of rectus abdominis (RA), external oblique (EO) and multifidus (MF) was measured using electromyography, along with sway of the centre of pressure (CoP) using a force platform. Only the EO and the MF muscles exhibited an increased activity with WT (p velocity and range of the CoP increased significantly with WT (p velocity of the CoP was marginally reduced (d = 0.29). WT elicited a greater level core muscle activation and created a greater challenge to postural stability when compared to a BB. It appears that WT does not benefit from vision but emphasises the somatosensory control of balance. The use of WT may be beneficial in those sports requiring development of somatosensory/proprioceptive contribution to balance control.

  4. Effects of premedication with oral gabapentin on intraocular pressure changes following tracheal intubation in clinically normal dogs.

    Science.gov (United States)

    Trbolova, Alexandra; Ghaffari, Masoud Selk; Capik, Igor

    2017-09-19

    Gabapentin is an antiepileptic drug widely approved as an add-on therapy for epilepsy treatment in human and dogs. There is a clinical impression that gabapentin is a suitable drug which attenuates the IOP elevation associated with tracheal intubation in humans. The present study performed to determine the effects of oral gabapentin on intraocular pressure (IOP) changes following tracheal intubation in dogs. Twenty adult healthy dogs were randomly assigned to treatment (n = 10) and control (n = 10) groups. Dogs in the treatment group received oral gabapentin (50 mg/kg) 2 h before induction of anesthesia and dogs in the control group received oral gelatin capsule placebo at the same time. The dogs were anesthetized with propofol 6 mg/kg, and anesthesia was maintained with a constant infusion of 0.2 mg/kg/min of propofol for 20 min. IOP were measured immediately before induction and then repeated immediately after induction, as well as 5 min, 10 min and 15 min following tracheal intubation in both groups. IOP was significantly higher immediately after induction, and 5 min after tracheal intubation when compared with IOP reading before induction in the control group. There was no statistically significant change in IOPs immediately after induction, and 5 min after tracheal intubation in comparison to the values before induction in the treatment group. Based on the findings of this study, preanesthetic oral administration of gabapentin significantly prevents an increase in the IOP associated with tracheal intubation in dogs anesthetized with propofol.

  5. Treatment of a case of tracheal stenosis in a dog with tracheal resection and anastomosis

    International Nuclear Information System (INIS)

    Mutlu, Z.; Acar, S.E.; Perk, C.

    2003-01-01

    A case of tracheal stenosis in the cervical portion of the trachea was encountered in a 5.5-month-old St. Bernard-Rottweiler cross dog. Breathing difficulty was seen in the clinical examination and presence of an obvious narrowing between the 3rd-5th cervical tracheal rings was determined in the radiological examination. Under general anesthesia the portion with stenosis was resected and the healthy trachea ends were anastomosed using the split cartilage technique. In the postoperative period the breathing difficulty disappeared and there was no development of a new stenosis in the anastomosis region. In the late period check-up the patient was seen to lead a healthy life

  6. Effects of acute respiratory virus infection upon tracheal mucous transport

    International Nuclear Information System (INIS)

    Gerrard, C.S.; Levandowski, R.A.; Gerrity, T.R.; Yeates, D.B.; Klein, E.

    1985-01-01

    Tracheal mucous velocity was measured in 13 healthy non-smokers using an aerosol labelled with /sup 99m/Tc and a multidetector probe during respiratory virus infections. The movement of boluses of tracheal mucous were either absent or reduced in number in five subjects with myxovirus infection (four influenza and one respiratory syncytial virus) within 48 hr of the onset of symptoms and in four subjects 1 wk later. One subject with influenza still had reduced bolus formation 12-16 wk after infection. Frequent coughing was a feature of those subjects with absent tracheal boluses. In contrast, four subjects with rhinovirus infection had normal tracheal mucous velocity at 48 hr after the onset of symptoms (4.1 +/- 1.3 mm/min). Tracheal mucous velocity was also normal (4.6 +/- 1.1 mm/min) in four subjects in whom no specific viral agent could be defined but had typical symptomatology of respiratory viral infection. During health tracheal mucous velocity was normal (4.8 +/- 1.6 mm/min) in the eleven subjects who had measurements made. Disturbances in tracheal mucous transport during virus infection appear to depend upon the type of virus and are most severe in influenza A and respiratory syncytial virus infection

  7. Polyflex stenting of tracheomalacia after surgery for congenital tracheal stenosis.

    Science.gov (United States)

    Tibballs, James; Fasulakis, Stephen; Robertson, Colin F; Berkowitz, Robert G; Massie, John; Brizard, Christian; Rose, Elizabeth; Bekhit, Elhamy; Eyres, Robert; Ragg, Philip

    2007-01-01

    Polyflex self-expanding stents (Rüsch, Germany) were used in three young children who had presented with life-threatening long-segment tracheal stenosis with bronchial stenosis in two cases. Two children had slide tracheoplasties and subsequently aortic homografts and another tracheal resection and autotracheoplasty. However, in all cases persistent lower tracheal malacia necessitated stenting. Complications of granuloma, stent migration or dislodgement occurred in all cases. A fatal tracheo-aortic fistula occurred in one child. Granuloma in one was treated successfully with steroids. One child survives.

  8. Prematurity and fetal lung response after tracheal occlusion in fetuses with severe congenital diaphragmatic hernia.

    Science.gov (United States)

    Sananes, Nicolas; Rodo, Carlota; Peiro, Jose Luis; Britto, Ingrid Schwach Werneck; Sangi-Haghpeykar, Haleh; Favre, Romain; Joal, Arnaud; Gaudineau, Adrien; Silva, Marcos Marques da; Tannuri, Uenis; Zugaib, Marcelo; Carreras, Elena; Ruano, Rodrigo

    2016-09-01

    To evaluate the independent association of fetal pulmonary response and prematurity to postnatal outcomes after fetal tracheal occlusion for congenital diaphragmatic hernia. Fetal pulmonary response, prematurity (prematurity (prematurity was not statistically associated with mortality after controlling for fetal pulmonary response (aOR 0.52, 95% CI 0.12-2.30, p=0.367). Fetal pulmonary response after FETO is the most important factor associated with survival, independently from the gestational age at delivery.

  9. Esophageal trachealization: A feature of eosinophilic esophagitis

    International Nuclear Information System (INIS)

    AlHussaini, Abdulrahman A; Semaan, Toufic; ElHag, Imad A

    2009-01-01

    Eosinophilic esophagitis (EE) is an inflammatory condition characterized by intense eosinophilic infiltration of the esophagus. EE is frequently misdiagnosed as gastroesophageal reflux disease. Here, we present a child with EE and a characteristic endoscopic finding, r inged esophagus . An 11-year-old Saudi boy presented with dysphagia for 1 year. He had experienced an intermittent sensation of solid food sticking in his chest, which was relieved by drinking liquids. A barium swallow excluded anatomical causes of dysphagia, but revealed multiple-ringed esophagus. Endoscopy showed a furrowing and trachealizing appearance of the entire esophagus. Hisologically, extensive eosinophilic infiltration was a feature in biopsies obtained from the esophagus. The child responded well to a 2-month course of inhaled fluticasone. Symptoms recurred 3 months after discontinuation of therapy, which necessitated resumption of inhaled fluticasone. The endoscopic appearance of multiple esophageal rings should raise suspicion of EE and be confirmed by esophageal biopsies. (author)

  10. Control rod guide tube wear in operating reactors; operating experience report. Technical report December 1977-December 1979

    International Nuclear Information System (INIS)

    Riggs, R.

    1980-04-01

    Evidence of control rod guide tube wear has been observed in operating pressurized water reactors. The cause of this wear is identified as flow-induced vibration of the control rods. This report describes the measures being taken by both the industry and the NRC to deal with this matter. The staff also presents its technical positions and requirements to support continued operation of the plants as of December 1979 pending completion of this generic effort

  11. Oral and endotracheal tubes colonization by periodontal bacteria: a case-control ICU study.

    Science.gov (United States)

    Porto, A N; Cortelli, S C; Borges, A H; Matos, F Z; Aquino, D R; Miranda, T B; Oliveira Costa, F; Aranha, A F; Cortelli, J R

    2016-03-01

    Periodontal infection is a possible risk factor for respiratory disorders; however, no studies have assessed the colonization of periodontal pathogens in endotracheal tubes (ET). This case-control study analyzed whether periodontal pathogens are able to colonize ET of dentate and edentulous patients in intensive care units (ICU) and whether oral and ET periodontal pathogen profiles have any correlation between these patients. We selected 18 dentate and 18 edentulous patients from 78 eligible ICU patients. Oral clinical examination including probing depth, clinical attachment level, gingival index , and plaque index was performed by a single examiner, followed by oral and ET sampling and processing by quantitative polymerase chain reaction (total bacterial load, Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and Tannerella forsythia). Data were statistically analyzed by Mann-Whitney U, two-way analysis of variance (p Periodontal pathogens can colonize ET and the oral cavity of ICU patients. Periodontal pathogen profiles tend to be similar between dentate and edentulous ICU patients. In ICU patients, oral cavity represents a source of ET contamination. Although accompanied by higher oral bacterial levels, teeth do not seem to influence ET bacterial profiles.

  12. Oral dextrose for analgesia in neonates during nasogastric tube insertion: a randomised controlled trial.

    Science.gov (United States)

    Ravishankar, Arjun; Thawani, Rajat; Dewan, Pooja; Das, Saurabhi; Kashyap, Archana; Batra, Prerna; Faridi, Moonis Mohammed Akbar

    2014-02-01

    This study aims to determine if oral dextrose solution can mitigate the pain response to nasogastric tube (NGT) insertion in neonates. The study was a double-blinded, placebo-controlled, randomised controlled trial. One hundred and fifty consecutive neonates were randomised into three groups to receive 25% dextrose (D25), or 10% dextrose (D10) or placebo (distilled water). An NGT was inserted after giving 2 mL of one of the solutions orally. Pain response was assessed using the Premature Infant Pain Profile (PIPP), and the duration of cry was noted within 60 s of the intervention. Total PIPP score, duration of cry, change in heart rate and oxygen saturation (SpO2 ) were compared among the three groups. Neonates who received D25 had significantly lesser pain response to NGT insertion in terms of lower PIPP score (P < 0.05) and duration of cry (P = 0.001) compared to D10. There was a significantly smaller increase in heart rate and decrease in SpO2 (P < 0.05). In comparison with placebo, D10 significantly decreased duration of cry (P < 0.05) but not PIPP score. Oral D25 was effective in reducing the pain response during NGT insertion in neonates when compared with oral D10 and placebo. Oral D10 was not found to have a potent analgesic effect for the same. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  13. Testing Placement of Gastric Feeding Tubes in Infants.

    Science.gov (United States)

    Metheny, Norma A; Pawluszka, Ann; Lulic, Melanie; Hinyard, Leslie J; Meert, Kathleen L

    2017-11-01

    Inadvertent positioning of a nasogastric tube in the lung can cause serious complications, so identifying methods to detect improperly inserted tubes is imperative. To compare the sensitivity, specificity, and negative and positive predictive values of 4 pH cut points (< 4.0, < 4.5, < 5.0, and < 5.5) in differentiating gastric and tracheal aspirates under various treatment conditions and to explore the utility of a pepsin assay for distinguishing between gastric and tracheal aspirates. Gastric and tracheal aspirates were collected from critically ill infants undergoing mechanical ventilation who had nasogastric or orogastric feeding tubes. Aspirates were tested with colorimetric pH indicators and a rapid pepsin assay. Information about treatment conditions was obtained from medical records. Two hundred twelve gastric aspirates and 60 tracheal aspirates were collected from 212 patients. Sensitivity was highest and specificity was lowest at the gastric aspirate pH cut point of less than 5.5. Positive predictive values were 100% at all pH cut points less than 5.0. Negative predictive values were higher at the pH cut point of less than 5.0 than at cut points less than 4.5. A higher percentage of pepsin-positive readings was found in gastric aspirates (88.3%) than in tracheal aspirates (5.4%). For a desired positive predictive value of 100%, a pH cut point of less than 5.0 provides the best negative predictive values, regardless of gastric acid inhibitor administration and feeding status. The pepsin assay is promising as an additional marker to distinguish gastric from tracheal aspirates. ©2017 American Association of Critical-Care Nurses.

  14. Reduction in degree of absorber-cladding mechanical interaction by shroud tube in control rods for the fast reactor

    International Nuclear Information System (INIS)

    Donomae, Takako; Katsuyama, Kozo; Tachi, Yoshiaki; Maeda, Koji; Yamamoto, Masaya; Soga, Tomonori

    2011-01-01

    Research and development of a long-life control rod for fast reactors is being conducted at Joyo. One of the challenges in developing a long-life control rod is the restraint of absorber-cladding mechanical interaction (ACMI). First, a helium-bonding rod was selected as a control rod for the experimental fast reactor Joyo, which is the first liquid metal fast reactor in Japan. Its lifetime was limited by ACMI, which is induced by the swelling and relocation of B 4 C pellets. To restrain ACMI, a shroud tube was inserted into the gap between the B 4 C pellets and the cladding tube. However, once B 4 C pellets cracked and broke into small fragments, relocation occurred. After this, the narrow gap closed immediately as the degree of B 4 C pellet swelling increased. To solve this problem, the gap was widened during design, and sodium was selected as the bonding material instead of helium to restrain the increase in pellet temperature. Irradiation testing of the modified sodium-bonding control rod confirmed that ACMI would be restrained by the shroud tube regardless of the occurrence of B 4 C pellet relocation. As a result of these improvements, the estimated lifetime of the control rod at Joyo was doubled. In this paper, the results of postirradiation examination are reported. (author)

  15. The Efficacy of Polydioxanone Monofilament Absorbable Suture for Tracheal Anastomosis

    OpenAIRE

    Kawahara, Katsunobu; Yamasaki, Naoya; Yamamoto, Satoshi; Nagayasu, Takeshi; Kusano, Hiroyuki; Akamine, Shinji; Takahashi, Takao; Tomita, Masao

    1994-01-01

    To evaluate the efficacy of polydioxanon absorbable suture for tracheal anastomoses, we performed an experimental study using dose. Eight adult mongrel dogs underwent sleeve resection of the mediastinal trachea. A length of ten to twelve cartilage rings was resected. An end-to-end anastomosis was performed using either interrupted or continuous running 4-0 polydioxanone (PDS) suture. There was no detectable difference bronchoscopically, microangiografically, or histologically, in tracheal ana...

  16. Relaxant effects of Ocimum basilicum on guinea pig tracheal chains and its possible mechanism(s

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Boskabady

    2005-01-01

    Full Text Available Therapeutic effects of Ocimum basilicum on respiratory diseases especially dyspnea have been reported in Iranian ancient medical books. In the present study, the relaxant effects of macerated and soxhlet extracts of this plant on tracheal chains of guinea pigs were evaluated. The relaxant effects of 4 cumulative concentrations of macerated and soxhlet extracts (0.25, 0.5, 0.75 and 1.0 W/V in comparison with saline as negative control and 4 cumulative concentrations of theophylline (0.25, 0.5, 0.75, and 1.0 mM as positive control were examined on precontracted tracheal chains of two groups of 6 guinea pig by 60 mM KCl (group 1 and 10 µM methacholine (group 2. Decrease in contractile tone of tracheal chains was considered as relaxant effect. In group 1 experiments only the last two higher concentrations of theophylline showed significant relaxant effect compared to that of saline (p<0.001 for both concentrations, which were significantly greater than those of macerated and soxhlet extracts (p<0.001 for all cases and in group 2 experiments both macerated and soxhlet extracts showed concentrationdependent relaxant effects compared to that of saline (p<0.05 to p<0.001 for both extracts. There were significant differences between the relaxant effects of both extracts with those of theophylline in group 2 experiments (p<0.01 to p<0.001. The relaxant effects of macerated and soxhlet extracts in group 1 were significantly lower than those of groups 2. These results showed a potent relaxant effect of Ocimum basilicum on tracheal chains of guinea pigs which were lower than theophylline at concentrations used.

  17. Gastrointestinal tolerance and plasma status of carotenoids, EPA and DHA with a fiber-enriched tube feed in hospitalized patients initiated on tube nutrition: Randomized controlled trial.

    Science.gov (United States)

    Jakobsen, L H; Wirth, R; Smoliner, C; Klebach, M; Hofman, Z; Kondrup, J

    2017-04-01

    During the first days of tube feeding (TF) gastrointestinal (GI) complications are common and administration of sufficient nutrition is a challenge. Not all standard nutritionally complete formulas contain dietary fiber, fish oil or carotenoids, key dietary nutrients for health and wellbeing. The aim of this study was to investigate the effects of a fiber, fish oil and carotenoid enriched TF formula on diarrhea, constipation and nutrient bioavailability. A multi-center randomized, double-blind, controlled, parallel trial compared the effects of a dietary fiber, fish oil and carotenoid-enriched TF formula (test) with an isocaloric non-enriched formula (control) in 51 patients requiring initiation of TF. Incidence of diarrhea and constipation (based on stool frequency and consistency) was recorded daily. Plasma status of EPA, DHA and carotenoids was measured after 7 days. The incidence of diarrhea was lower in patients receiving the test formula compared with the control group (19% vs. 48%, p = 0.034). EPA and DHA status (% of total plasma phospholipids) was higher after 7 days in test compared with control group (EPA: p = 0.002, DHA: p = 0.082). Plasma carotenoid levels were higher after 7 days in the test group compared with control group (lutein: p = 0.024, α-carotene: p = 0.005, lycopene: p = 0.020, β-carotene: p = 0.054). This study suggests that the nutrient-enriched TF formula tested might have a positive effect on GI tolerance with less diarrhea incidence and significantly improved EPA, DHA and carotenoid plasma levels during the initiation of TF in hospitalized patients who are at risk of diarrhea and low nutrient status. This trial was registered at trialregister.nl; registration number 2924. Copyright © 2016. Published by Elsevier Ltd.

  18. New Approaches to Airway Management in Tracheal Resections-A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Schieren, Mark; Böhmer, Andreas; Dusse, Fabian; Koryllos, Aris; Wappler, Frank; Defosse, Jerome

    2017-08-01

    Although endotracheal intubation, surgical crossfield intubation, and jet ventilation are standard techniques for airway management in tracheal resections, there are also reports of new approaches, ranging from regional anesthesia to extracorporeal support. The objective was to outline the entire spectrum of new airway techniques. The literature databases PubMed/Medline and the Cochrane Library were searched systematically for prospective and retrospective trials as well as case reports on tracheal resections. No restrictions applied to hospital types or settings. Adult patients undergoing surgical resections of noncongenital tracheal stenoses with end-to-end anastomoses. Airway management techniques were divided into conventional and new approaches and analyzed regarding their potential risks and benefits. A total of 59 publications (n = 797 patients) were included. The majority of publications (71.2%) describe conventional airway techniques. Endotracheal tube placement after induction of general anesthesia and surgical crossfield intubation after incision of the trachea were used most frequently without major complications. A total of 7 new approaches were identified, including 4 different regional anesthetic techniques (25 cases), supraglottic airways (4 cases), and new forms of extracorporeal support (25 cases). Overall failure rates of new techniques were low (1.8%). Details on patient selection and procedural specifics are provided. New approaches have several theoretical benefits, yet further research is required to establish criteria for patient selection and evaluate procedural safety. Given the low level of evidence, it currently is impossible to compare methods of airway management regarding outcome-related risks and benefits. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Comparison of four techniques of nasogastric tube insertion in anaesthetised, intubated patients: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Mohan Chandra Mandal

    2014-01-01

    Full Text Available Background and Aims: Insertion of nasogastric tubes (NGTs in anaesthetised, intubated patients with a conventional method is sometimes difficult. Different techniques of NGT insertion have been tried with varying degree of success. The aim of this prospective, randomised, open-label study was to evaluate three modified techniques of NGT insertion comparing with the conventional method in respect of success rate, time taken for insertion and the adverse events. Methods: In the operation theatre of general surgery, the patients were randomly allocated into four groups: Group C (control group, n = 54, Group W (ureteral guide wire group, n = 54, Group F (neck flexion with lateral pressure, n = 54 and Group R (reverse Sellick′s manoeuvre, n = 54. The number of attempts for successful NGT insertion, time taken for insertion and adverse events were noted. Results: All the three modified techniques were found more successful than the conventional method on the first attempt. The least time taken for insertion was noted in the reverse Sellick′s method. However, on intergroup analysis, neck flexion and reverse Sellick′s methods were comparable but significantly faster than the other two methods with respect to time taken for insertion. Conclusion: Reverse Sellick′s manoeuver, neck flexion with lateral neck pressure and guide wire-assisted techniques are all better alternatives to the conventional method for successful, quick and reliable NGT insertion with permissible adverse events in anaesthetised, intubated adult patients. Further studies after eliminating major limitations of the present study are warranted to establish the superiority of any one of these modified techniques.

  20. Analysis of Communication between Main Control Room Operators in Decision-making Process in Steam Generator Tube Rupture Accident

    International Nuclear Information System (INIS)

    Petkov, M.; Petkov, G.

    2006-01-01

    The paper presents an investigation results for Main Control Room operators' reliability by Performance Evaluation of Teamwork method, based on FSS-1000 training archives in KNPP in case of Steam Generator Tube Rupture accident. The advantages of operators' teamwork are shown: a) group decision-making vs. individual one: b) positive influence of crew initiated communication consisting of orders and reports that are required by instruction. (authors)

  1. Canine tracheal epithelial cells are more sensitive than rat tracheal epithelial cells to transforming growth factor beta induced growth inhibition

    International Nuclear Information System (INIS)

    Hubbs, A.F.; Hahn, F.F.; Kelly, G.; Thomassen, D.G.

    1988-01-01

    Transforming growth factor beta (TGFβ) markedly inhibited growth of canine tracheal epithelial (CTE) cells. Reduced responsiveness to TGFβ-induced growth inhibition accompanied neoplastic progression of these cells from primary to transformed to neoplastic. This was similar to the relationship between neoplastic progression and increased resistance to TGFβ-induced growth inhibition seen for rat tracheal epithelial (RTE) cells. The canine cells were more sensitive than rat cells to TGFβ-induced growth inhibition at all stages in the neoplastic process. (author)

  2. The Quality Assurance_Quality Control of the Monitored Drift Tubes at the HEP Laboratory of the National Technical University of Athens

    CERN Document Server

    Alexopoulos, T; Dris, M; Filippas, A V; Fokitis, E; Gazis, E N; Katsoufis, E C; Maltezos, A; Maltezos, S; Papadopoulos, E; Papadopoulou, T D; Savva, Panagiota S; Stavropoulos, G D; Tsipolitis, G; Tzamariudaki, E

    2001-01-01

    The description of the Quality Assurance and Quality Control (QA_QC) procedures for the Monitored Drift Tubes (MDT's) followed at the HEP Laboratory of NTUA are presented and results of the tested tubes are given. The MDT's are the elements from which muon chambers for the ATLAS/LHC Muon Spectrometer are built..

  3. New insights into controlling tube-bundle fouling using alternative amines

    Energy Technology Data Exchange (ETDEWEB)

    Turner, C.W.; Klimas, S.J.; Guzonas, D.A.; Fruzzetti, K. [Atomic Energy of Canada Ltd. (Canada); Frattini, P.L. [Electric Power Research Inst. (United States)

    2002-07-01

    A volatile amine is added to the secondary heat-transport system of a nuclear power plant to reduce the rate of corrosion and corrosion product transport in the feedwater and to protect steam generator (SG) crevices and materials exposed to steam condensate. Volatility and base strength of the amine at the SG operating temperature are two important considerations when choosing the optimum amine (or mixture of amines) for corrosion control in the steam cycle. The investigation has found that the rate of tube-bundle fouling is strongly dependent upon the surface chemistry of the corrosion products. For example, the fouling rates of fully oxidized iron oxides, such as hematite and lepidocrocite, are at least an order of magnitude greater than the fouling rate of magnetite under identical operating conditions. The difference is related to the sign of the surface charge on the corrosion products at temperature. The choice of amine for pH-control also influences the fouling rate. This was originally thought to be a surface-charge effect as well, but recent tests have suggested that it is related to the role that the amine plays in governing the rate of deposit consolidation on the heat-transfer surface. Amines that promote a high rate of deposit consolidation result in a low rate of deposit removal and a high fouling rate. Conversely, amines that tend to inhibit deposit consolidation produce a higher rate of deposit removal and a lower fouling rate. Dimethyl-amine and dodecyl-amine have been identified as two amines that inhibit the rate of deposit consolidation and, consequently, result in fouling rates that are up to 5 times lower than rates measured for amines that promote consolidation. A significant difference between morpholine (high fouling rate) and dimethyl-amine (low fouling rate) is that the latter desorbs more slowly from the surface of magnetite. How to account for a correlation between slow desorption kinetics and lower rate constants for deposition and

  4. New insights into controlling tube-bundle fouling using alternative amines

    International Nuclear Information System (INIS)

    Turner, C.W.; Klimas, S.J.; Guzonas, D.A.; Fruzzetti, K.; Frattini, P.L.

    2002-01-01

    A volatile amine is added to the secondary heat-transport system of a nuclear power plant to reduce the rate of corrosion and corrosion product transport in the feedwater and to protect steam generator (SG) crevices and materials exposed to steam condensate. Volatility and base strength of the amine at the SG operating temperature are two important considerations when choosing the optimum amine (or mixture of amines) for corrosion control in the steam cycle. The investigation has found that the rate of tube-bundle fouling is strongly dependent upon the surface chemistry of the corrosion products. For example, the fouling rates of fully oxidized iron oxides, such as hematite and lepidocrocite, are at least an order of magnitude greater than the fouling rate of magnetite under identical operating conditions. The difference is related to the sign of the surface charge on the corrosion products at temperature. The choice of amine for pH-control also influences the fouling rate. This was originally thought to be a surface-charge effect as well, but recent tests have suggested that it is related to the role that the amine plays in governing the rate of deposit consolidation on the heat-transfer surface. Amines that promote a high rate of deposit consolidation result in a low rate of deposit removal and a high fouling rate. Conversely, amines that tend to inhibit deposit consolidation produce a higher rate of deposit removal and a lower fouling rate. Dimethyl-amine and dodecyl-amine have been identified as two amines that inhibit the rate of deposit consolidation and, consequently, result in fouling rates that are up to 5 times lower than rates measured for amines that promote consolidation. A significant difference between morpholine (high fouling rate) and dimethyl-amine (low fouling rate) is that the latter desorbs more slowly from the surface of magnetite. How to account for a correlation between slow desorption kinetics and lower rate constants for deposition and

  5. Randomized Pilot Trial of Two Modified Endotracheal Tubes To Prevent Ventilator-associated Pneumonia.

    Science.gov (United States)

    Deem, Steven; Yanez, David; Sissons-Ross, Laura; Broeckel, Jo Ann Elrod; Daniel, Stephen; Treggiari, Miriam

    2016-01-01

    Ventilator-associated pneumonia (VAP) is a prevalent and costly nosocomial infection related to instrumentation of the airway with an endotracheal tube (ETT), enabling microaspiration of contaminated secretions. Modification of the ETT design to reduce microaspiration and/or biofilm formation may play an important role in VAP prevention. However, there is insufficient evidence to provide strong recommendations regarding the use of modified ETT and unaddressed safety concerns. We performed a pilot randomized controlled trial comparing two modified ETTs designed specifically to prevent VAP, with the standard ETT, to test the feasibility of and inform planning for a large, pivotal, randomized trial. This study was conducted with institutional review board approval under exception from informed consent. We randomized in a blinded fashion patients undergoing emergency endotracheal intubation both out of and in hospital to receive one of three different ETT types: (1) a polyurethane-cuffed tube (PUC-ETT), (2) a polyurethane-cuffed tube equipped with a port for continuous aspiration of subglottic secretions (PUC-CASS-ETT), or a (3) standard polyvinylchloride-cuffed tube (PVC-ETT). In addition to investigating feasibility and safety, the study coprimary end points were tracheal bacterial colonization reaching a cfu count >10(6) cfu per milliliter and the incidence of invasively diagnosed VAP. A total of 102 subjects were randomized and met the eligibility criteria. Randomization procedures performed well and integrity of blinding at randomization was maintained. The majority of intubations occurred in the hospital setting (n = 77), and the remainder occurred out of hospital (n = 25). Compared with the PVC-ETT, there were no significant differences in tracheal colonization for PUC-ETT (odds ratio [OR], 0.98; 95% confidence interval [CI], 0.31-3.09) or for PUC-CASS-ETT (OR, 1.26; 95% CI, 0.42-3.76). There were no differences in the risk of invasively diagnosed VAP

  6. I-gel Laryngeal Mask Airway Combined with Tracheal Intubation Attenuate Systemic Stress Response in Patients Undergoing Posterior Fossa Surgery

    Directory of Open Access Journals (Sweden)

    Chaoliang Tang

    2015-01-01

    patients. In this study, we proposed that I-gel combined with tracheal intubation could reduce the stress response of posterior fossa surgery patients. Methods. Sixty-six posterior fossa surgery patients were randomly allocated to receive either tracheal tube intubation (Group TT or I-gel facilitated endotracheal tube intubation (Group TI. Hemodynamic and respiratory variables, stress and inflammatory response, oxidative stress, anesthesia recovery parameters, and adverse events during emergence were compared. Results. Mean arterial pressure and heart rate were lower in Group TI during intubation and extubation (P<0.05 versus Group TT. Respiratory variables including peak airway pressure and end-tidal carbon dioxide tension were similar intraoperative, while plasma β-endorphin, cortisol, interleukin-6, tumor necrosis factor-alpha, malondialdehyde concentrations, and blood glucose were significantly lower in Group TI during emergence relative to Group TT. Postoperative bucking and serious hypertensions were seen in Group TT but not in Group TI. Conclusion. Utilization of I-gel combined with endotracheal tube in posterior fossa surgery patients is safe which can yield more stable hemodynamic profile during intubation and emergence and lower inflammatory and oxidative response, leading to uneventful recovery.

  7. Fetal MRI in experimental tracheal occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, Ulrike [Department of Diagnostic and Interventional Radiology, Universitaetsklinikum Hamburg-Eppendorf, Martinistrasse 52, 20251 Hamburg (Germany)]. E-mail: wedegaer@uke.uni-hamburg.de; Schroeder, Hobe J. [Experimental Gynecology, Department of Obstetrics and Prenatal Medicine, Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany); Adam, Gerhard [Department of Diagnostic and Interventional Radiology, Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany)

    2006-02-15

    Congenital diaphragmatic hernia (CDH) is associated with a high mortality, which is mainly due to pulmonary hypoplasia and secondary pulmonary hypertension. In severely affected fetuses, tracheal occlusion (TO) is performed prenatally to reverse pulmonary hypoplasia, because TO leads to accelerated lung growth. Prenatal imaging is important to identify fetuses with pulmonary hypoplasia, to diagnose high-risk fetuses who would benefit from TO, and to monitor the effect of TO after surgery. In fetal imaging, ultrasound (US) is the method of choice, because it is widely available, less expensive, and less time-consuming to perform than magnetic resonance imaging (MRI). However, there are some limitations for US in the evaluation of CDH fetuses. In those cases, MRI is helpful because of a better tissue contrast between liver and lung, which enables evaluation of liver herniation for the diagnosis of a high-risk fetus. MRI provides the ability to determine absolute lung volumes to detect lung hypoplasia. In fetal sheep with normal and hyperplastic lungs after TO, lung growth was assessed on the basis of cross-sectional US measurements, after initial lung volume determination by MRI. To monitor fetal lung growth after prenatal TO, both MRI and US seem to be useful methods.

  8. Computerized ultrasonic quality control system in the production of helical welded tubes

    International Nuclear Information System (INIS)

    Tar, J.

    1976-01-01

    The inspection of helical welded steel tubes by means of an ultrasonic automatic equipment is described. This equipment is able to recognize the defects of the weld, to identify them and to continuously report back the informations necessary for their elimination

  9. The control of stainless steel tubes and wires of small diameter by the Eddy current method

    International Nuclear Information System (INIS)

    Stossel, A.; Gallet, G.

    1978-01-01

    Stainless steel tubes and wires with an outer diameter greater than 1 mm were studied by Eddy currents. The sensor characteristics and the detection of defects in function of frequency are presented together with the results obtained in the detection of dimensional and metallurgical defects [fr

  10. Permeation tubes. Their use in the preparation of controlled gas atmospheres

    International Nuclear Information System (INIS)

    Galianos, J. A.; Palomares, F.

    1981-01-01

    In this paper, the state of the art on the nature, construction and properties of the permeation tubes Is reviewed; after describing the main calibration procedures In use, examples of their application in the area of the atmospheric pollution are given, especially in the case of sulfur dioxides. (Author) 38 refs

  11. Design of process parameters for the incremental tube forming (ITF) by FEM to control product properties

    Science.gov (United States)

    Nazari, Esmaeil; Löbbe, Christian; Gallus, Stefan; Izadyar, S. Ahmad; Tekkaya, A. Erman

    2018-05-01

    The incremental tube forming (ITF) is a process combination of the kinematic tube bending and spinning to shape high strength and tailored tubes with variable diameters and thicknesses. In contrast to conventional bending methods, the compressive stress superposition by the spinning process facilitates low bending stresses, so that geometrical errors are avoided and the shape accuracy is improved. The study reveals the interaction of plastic strains of the rolling and bending process through an explicit FEM investigation. For this purpose, the three-dimensional machine set-up is discretized and modeled in terms of the fully disclosed spinning process during the gradual deflection of the tube end for bending. The analysis shows that, depending on the forming tool shape, the stress superposition is accompanied by high plastic strains. Furthermore, this phenomenon is explained by the three dimensional normal and shear strains during the incremental spinning. Analyzing the strains history also shows a nonlinearity between the strains by bending and spinning. It is also shown that process parameters like rotational velocity of the spinning rolls have a huge influence on the deformation pattern. Finally, the method is used for the manufacturing of an example product, which reveals the high process flexibility. In one clamp a component with a graded wall thickness and outside diameter along the longitudinal axis is produced.

  12. Successful Treatment of Anterior Tracheal Necrosis after Total Thyroidectomy Using Vacuum-Assisted Closure Therapy

    Directory of Open Access Journals (Sweden)

    Grégory Philippe

    2012-01-01

    Full Text Available Total thyroidectomy involving the adjacent structures of the trachea can cause tracheal damage such as early tracheal necrosis. The authors describe the first case of anterior tracheal necrosis following total thyroidectomy treated using vacuum-assisted closure device. After two weeks of VAC  therapy, there was no evidence of ongoing infection and the trachea was partially closed around a tracheotomy cannula, removed after 3 months. The use of a VAC  therapy to reduce and close the tracheal rent and to create a rapid granulation tissue over tracheal structure appeared as a good opportunity after anterior tracheal necrosis.

  13. Comparative efficacy of Combination of Propofol or Thiopental with Remifentanil on Tracheal Intubation without Muscle Relaxants

    Directory of Open Access Journals (Sweden)

    k Naseri

    2007-10-01

    Full Text Available Introduction & Objective: In some medical situations administration of muscle relaxants after intravenous anesthetics for tracheal intubation may be unnecessary or sometimes could be hazardous. In such situations, replacing an alternative drug for the facilitation of tracheal intubation is obvious. Remifentanil is a short acting opioid drug which may be useful in solving this problem. The aim of this study was to compare the effects of propofol or thiopental in combination with remifentanil in the absence of muscle relaxants on larengoscopy and intubation conditions in general anesthesia. Materials & Methods: This is a randomized double-blind clinical trial which was performed in 1386 in Be’sat hospital of Sanandaj. Forty two ASA 1 and 2 patients recruited to receive propofol, 2 Mg/Kg, or thiopental, 5Mg/K. All patients received lidocaine, 1.5 Mg/Kg, and remifentanil, 2.5 µg/Kg, 30 seconds before anesthetics administration. larengoscopy and tracheal intubation were done 90 seconds after induction of anesthesia. On the basis of mask ventilation, jaw relaxation, vocal cords position and patient's response to intubations and endotracheal tube cuff inflation the intubation conditions were assessed and recorded as excellent, good ,acceptable or poor. The mean arterial pressure and heart rate were measured before and after anesthetics administration and also 45 seconds and two and five minutes after intubations. Data were analyzed by X2, fisher exact test ant student T-test using SPSS software. Results: Excellent or good larengoscopy and intubation conditions were observed in 9 (%42.9 of thiopental patients and 20 (%95.2 of propofol patients (p<0.05. Mean arterial pressure and heart rate decreased more significantly in propofol group in comparison with the thiopental group (p<0.05. Conclusion: Combination of remifentanil and propofol or thiopental could facilitate ventilation via face mask in all patients. Although combination of propofol and

  14. Wear plates control rod guide tubes top internal reactor vessel C. N. VANDELLOS II; Desgaste placas tubos guia barras de control interno superior vasija del reactor C.N. Vandellos II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    The guide tubes for control rods forming part of the upper internals of the reactor vessel, its function is to guide the control rod to permit its insertion in the reactor core. These guide tubes are suspended from the upper support plate which are fixed by bolts and extending to the upper core plate which is fastened by clamping bolts (split pin) to prevent lateral displacement of the guide tubes, while allowing axial expansion.

  15. Validation study of two-microphone acoustic reflectometry for determination of breathing tube placement in 200 adult patients.

    Science.gov (United States)

    Raphael, David T; Benbassat, Maxim; Arnaudov, Dimiter; Bohorquez, Alex; Nasseri, Bita

    2002-12-01

    Acoustic reflectometry allows the construction of a one-dimensional image of a cavity, such as the airway or the esophagus. The reflectometric area-distance profile consists of a constant cross-sectional area segment (length of endotracheal tube), followed either by a rapid increase in the area beyond the carina (tracheal intubation) or by an immediate decrease in the area (esophageal intubation). Two hundred adult patients were induced and intubated, without restrictions on anesthetic agents or airway adjunct devices. A two-microphone acoustic reflectometer was used to determine whether the breathing tube was placed in the trachea or esophagus. A blinded reflectometer operator, seated a distance away from the patient, interpreted the acoustic area-distance profile alone to decide where the tube was placed. Capnography was used as the gold standard. Of 200 tracheal intubations confirmed by capnography, the reflectometer operator correctly identified 198 (99% correct tracheal intubation identification rate). In two patients there were false-negative results, patients with a tracheal intubation were interpreted as having an esophageal intubation. A total of 14 esophageal intubations resulted, all correctly identified by reflectometry, for a 100% esophageal intubation identification rate. Acoustic reflectometry is a rapid, noninvasive method by which to determine whether breathing tube placement is correct (tracheal) or incorrect (esophageal). Reflectometry determination of tube placement may be useful in airway emergencies, particularly in cases where visualization of the glottic area is not possible and capnography may fail, as in patients with cardiac arrest.

  16. Tube plug

    International Nuclear Information System (INIS)

    Zafred, P. R.

    1985-01-01

    The tube plug comprises a one piece mechanical plug having one open end and one closed end which is capable of being inserted in a heat exchange tube and internally expanded into contact with the inside surface of the heat exchange tube for preventing flow of a coolant through the heat exchange tube. The tube plug also comprises a groove extending around the outside circumference thereof which has an elastomeric material disposed in the groove for enhancing the seal between the tube plug and the tube

  17. Tracheal intubation in the ICU: Life saving or life threatening?

    Directory of Open Access Journals (Sweden)

    Jigeeshu V Divatia

    2011-01-01

    Full Text Available Tracheal intubation (TI is a routine procedure in the intensive care unit (ICU, and is often life saving. However, life-threatening complications occur in a significant proportion of procedures, making TI perhaps one the most common but underappreciated airway emergencies in the ICU. In contrast to the controlled conditions in the operating room (OR, the unstable physiologic state of critically ill patients along with underevaluation of the airways and suboptimal response to pre-oxygenation are the major factors for the high incidence of life-threatening complications like severe hypoxaemia and cardiovascular collapse in the ICU. Studies have shown that strategies planned for TI in the OR can be adapted and extrapolated for use in the ICU. Non-invasive positive-pressure ventilation for pre-oxygenation provides adequate oxygen stores during TI for patients with precarious respiratory pathology. The intubation procedure should include not only airway management but also haemodynamic, gas exchange and neurologic care, which are often crucial in critically ill patients. Hence, there is a necessity for the implementation of an Intubation Bundle during routine airway management in the ICU. Adherence to a plan for difficult airway management incorporating the use of intubation aids and airway rescue devices and strategies is useful.

  18. Effect of Fluticasone and Salmeterol on Tracheal Responsiveness to Ovalbumin and Lung Inflammation, Administrated during and after Sensitization

    Directory of Open Access Journals (Sweden)

    Zahra Gholamnezhad

    2014-01-01

    Full Text Available The effect of duration of administration of fluticasone propionate and salmeterol on tracheal responsiveness to ovalbumin and total and differential white blood cell in sensitized guinea pig was examined. Six groups of guinea pigs (n=7 were sensitized to ovalbumin. Three groups of them were subjected to inhaled fluticasone propionate and salmeterol, one group during sensitization (A, one group after that (for 18 days, B, and the other one during sensitization but with 18 days delay before measurements (C. Three other groups were treated with placebo in the same manner. The tracheal responsiveness to ovalbumin and total and differential white blood cells of three placebo groups were significantly higher than those of control group (P<0.001 for all cases. Tracheal responsiveness to ovalbumin and total and differential white blood cell in treated groups with fluticasone propionate and salmeterol were significantly decreased compared to those of placebo groups (nonsignificant to P<0.001. The improvement in all variables in treatment groups A and C were more pronounced than group B. The results showed that fluticasone propionate and salmeterol had a prevention effect on tracheal hyperresponsiveness to ovalbumin and lung inflammation which was more pronounced when administered during than after sensitization.

  19. Particular treatments in Eddy current technique. Application to the control of corrugated tubes

    International Nuclear Information System (INIS)

    1982-11-01

    When the testing of a given product shows that, owing to a particular shape of this product or to its environment, disturbing effects can hide the presence of harmful defects, use must be made of testing artifices or particular treatments enabling an efficient examination to be made. On this score, many eddy current problems are solved by means of the following processes: - use of specific sensors adapted to the geometry of the product, - spectral analysis of the analog results of analyses, - combination of the results of analyses obtained simultaneously at different frequencies (multifrequency techniques). An example of an application is given for corrugated tubes achieved by hollow and helical milling of smooth tubes [fr

  20. Vardenafil inhibiting parasympathetic function of tracheal smooth muscle.

    Science.gov (United States)

    Lee, Fei-Peng; Chao, Pin-Zhir; Wang, Hsing-Won

    2018-07-01

    Levitra, a phosphodiesterase-5 (PDE5) inhibitor, is the trade name of vardenafil. Nowadays, it is applied to treatment of erectile dysfunction. PDE5 inhibitors are employed to induce dilatation of the vascular smooth muscle. The effect of Levitra on impotency is well known; however, its effect on the tracheal smooth muscle has rarely been explored. When administered for sexual symptoms via oral intake or inhalation, Levitra might affect the trachea. This study assessed the effects of Levitra on isolated rat tracheal smooth muscle by examining its effect on resting tension of tracheal smooth muscle, contraction caused by 10 -6  M methacholine as a parasympathetic mimetic, and electrically induced tracheal smooth muscle contractions. The results showed that adding methacholine to the incubation medium caused the trachea to contract in a dose-dependent manner. Addition of Levitra at doses of 10 -5  M or above elicited a significant relaxation response to 10 -6  M methacholine-induced contraction. Levitra could inhibit electrical field stimulation-induced spike contraction. It alone had minimal effect on the basal tension of the trachea as the concentration increased. High concentrations of Levitra could inhibit parasympathetic function of the trachea. Levitra when administered via oral intake might reduce asthma attacks in impotent patients because it might inhibit parasympathetic function and reduce methacholine-induced contraction of the tracheal smooth muscle. Copyright © 2018. Published by Elsevier Taiwan LLC.

  1. Failed tracheal intubation using a laryngoscope and intubating laryngeal mask.

    Science.gov (United States)

    Asai, T; Hirose, T; Shingu, K

    2000-04-01

    To report unexpected failed tracheal intubation using a laryngoscope and an intubating laryngeal mask, and difficult ventilation via a facemask, laryngeal mask and intubating laryngeal mask, in a patient with an unrecognized lingual tonsillar hypertrophy. A 63-yr-old woman, who had undergone clipping of an aneurysm seven weeks previously, was scheduled for ventriculo-peritoneal shunt. At the previous surgery, there had been no difficulty in ventilation or in tracheal intubation. Her trachea remained intubated nasally for 11 days after surgery. Preoperatively, her consciousness was impaired. There were no restrictions in head and neck movements or mouth opening. The thyromental distance was 7 cm. After induction of anesthesia, manual ventilation via a facemask with a Guedel airway was suboptimal and the chest expanded insufficiently. At laryngoscopy using a Macintosh or McCoy device, only the tip of the epiglottis, but not the glottis, could be seen, and tracheal intubation failed. There was a partial obstruction during manual ventilation through either the intubating laryngeal mask or conventional laryngeal mask; intubation through each device failed. Digital examination of the pharynx, after removal of the laryngeal mask, indicated a mass occupying the vallecula. Lingual tonsillar hypertrophy (1 x 1 x 2 cm) was found to be the cause of the failure. Awake fibrescope-aided tracheal intubation was accomplished. Unexpected lingual tonsillar hypertrophy can cause both ventilation and tracheal intubation difficult, and neither the laryngeal mask nor intubating laryngeal mask may be helpful in the circumstances.

  2. Remote controller for tool moving in tube especially rotopeenig tool in steam generator

    International Nuclear Information System (INIS)

    Tocci, J.L.; Blotas, B.; Francois, D.

    1988-01-01

    To introduce at distance a tool such a rotopeening tool in a tube, the tool is attached to the extremity of a flexible cable which is enclosed in a flexible sheath. The sheath extremity is fixed on the arm of a carrier. The other extremity of the sheath is fixed in translation on a command bed. The tool introduction is made by a motoreduction gear placed on the bed translating the extremity of the sheath by pinion-rack system [fr

  3. Effects of tracheal orientation on development of ventilator-associated pneumonia: an experimental study.

    Science.gov (United States)

    Zanella, Alberto; Cressoni, Massimo; Epp, Myra; Hoffmann, Viktoria; Stylianou, Mario; Kolobow, Theodor

    2012-04-01

    Orientation of the trachea and tracheal tube below horizontal may prevent aspiration of oropharyngeal secretions into the lungs, which is a pivotal pathway in the pathogenesis of ventilator-associated pneumonia (VAP). The incidence of VAP was evaluated in swine with orientation of trachea and tracheal tube above horizontal (model of semirecumbent position, currently recommended in patients) and below horizontal. Twenty-six mini-pigs were randomized into four groups: (A) eight mechanically ventilated with orientation of trachea 45° above horizontal for 72 h. In the remaining groups (B, C, D) the trachea was oriented 10° below horizontal, with (B) six mechanically ventilated for 72 h, (C) six mechanically ventilated for 72 h with enteral feeding, and (D) six mechanically ventilated for 168 h with enteral feeding. At the end of the study period, all pigs were sacrificed and the clinical diagnosis of VAP was microbiologically evaluated. No antibiotics were administered. All eight pigs kept orientated with the trachea 45° above horizontal developed VAP and respiratory failure (PaO(2)/F(i)O(2) = 132 ± 139 mmHg) with a median of 5.5 pulmonary lobes out of 6 colonized with average colonization of 9.3 × 10(7) CFU/g. None of the 18 pigs kept oriented with the trachea below horizontal developed VAP; 16 had sterile lungs, while 2, ventilated for 7 days, developed a low level of colonization. Orientation of the trachea above horizontal was uniformly associated with VAP and respiratory failure; positioning the trachea below horizontal consistently prevented development of VAP.

  4. Operational control and maintenance integrity of typical and atypical coil tube steam generating systems

    Energy Technology Data Exchange (ETDEWEB)

    Beardwood, E.S.

    1999-07-01

    Coil tube steam generators are low water volume to boiler horsepower (bhp) rating, rapid steaming units which occupy substantially less space per boiler horsepower than equivalent conventional tire tube and water tube boilers. These units can be retrofitted into existing steam systems with relative ease and are more efficient than the generators they replace. During the early 1970's they became a popular choice for steam generation in commercial, institutional and light to medium industrial applications. Although these boiler designs do not require skilled or certified operators, an appreciation for a number of the operational conditions that result in lower unscheduled maintenance, increased reliability and availability cycles would be beneficial to facility owners, managers, and operators. Conditions which afford lower operating and maintenance costs will be discussed from a practical point of view. An overview of boiler design and operation is also included. Pitfalls are provided for operational and idle conditions. Water treatment application, as well as steam system operations not conducive to maintaining long term system integrity; with resolutions, will be addressed.

  5. Gastrostomy Tube (G-Tube)

    Science.gov (United States)

    ... any of these problems: a dislodged tube a blocked or clogged tube any signs of infection (including redness, swelling, or warmth at the tube site; discharge that's yellow, green, or foul-smelling; fever) excessive bleeding or drainage from the tube site severe abdominal pain lasting ...

  6. Exploring the use of entertainment-education YouTube videos focused on infection prevention and control.

    Science.gov (United States)

    Lim, Kathryn; Kilpatrick, Claire; Storr, Julie; Seale, Holly

    2018-06-05

    As a communications strategy, education entertainment has been used to inform, influence, and shift societal and individual behaviors. Recently, there has been an increasing number of entertainment-education YouTube videos focused on hand hygiene. However, there is currently no understanding about the quality of these videos; therefore, this study aimed to explore the social media content and user engagement with these videos. The search terms "hand hygiene" and "hand hygiene education" were used to query YouTube. Video content had to be directed at a health care professional audience. Using author designed checklists, each video was systematically evaluated and grouped according to educational usefulness and was subsequently evaluated against the categories of attractiveness, comprehension, and persuasiveness. A total of 400 videos were screened, with 70 videos retained for analysis. Of these, 55.7% (n = 39) were categorized as educationally useful. Overall, educationally useful videos scored higher than noneducationally useful videos across the categories of attractiveness, comprehension, and persuasiveness. Miscommunication of the concept of My 5 Moments for Hand Hygiene was observed in several of the YouTube videos. The availability of educationally useful videos in relation to hand hygiene is evident; however, it is clear that there are opportunities for contributors using this medium to strengthen their alignment with social media best practice principles to maximize the effectiveness, reach, and sustainability of their content. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Evaluation of a smartphone camera system to enable visualization and image transmission to aid tracheal intubation with the Airtraq(®) laryngoscope.

    Science.gov (United States)

    Lee, Delice Weishan; Thampi, Swapna; Yap, Eric Peng Huat; Liu, Eugene Hern Choon

    2016-06-01

    Using three-dimensional printing, we produced adaptors to attach a smartphone with camera to the eyepiece of the Airtraq(®) laryngoscope. This low-cost system enabled a team to simultaneously view the laryngoscopy process on the smartphone screen, and also enabled image transmission. We compared the Airtraq(®) with the smartphone Airtraq(®) system in a crossover study of trainee anesthesiologists performing tracheal intubation in a manikin. We also evaluated the smartphone Airtraq(®) system for laryngoscopy and tracheal intubation in 30 patients, including image transmission to and communication with a remote instructor. In the manikin study, the smartphone Airtraq(®) system enabled instruction where both trainee and instructor could view the larynx simultaneously, and did not substantially increase the time required for intubation. In the patient study, we were able to view the larynx in all 30 patients, and the remote instructor was able to receive the images and to respond on correctness of laryngoscopy and tracheal tube placement. Tracheal intubation was successful within 90s in 19 (63 %) patients. In conclusion, use of a smartphone with the Airtraq(®) may facilitate instruction and communication of laryngoscopy with the Airtraq(®), overcoming some of its limitations.

  8. Effect of rocuronium on the bispectral index under anesthesia and tracheal intubation.

    Science.gov (United States)

    Yue, Hui; Han, Jinyu; Liu, Ling; Wang, Kaiyuan; Li, Jincheng

    2016-12-01

    The aim of the present study was to investigate the effect of various doses of rocuronium on bispectral index (BIS) responses to propofol induction and tracheal intubation, as well as the role of the non-depolarization muscle relaxant rocuronium on the depth of sedation. A total of 72 patients (American Society of Anesthesiologists physical status I-II) were anaesthetized with propofol using a target-controlled infusion, and randomly divided into two sedation level groups (n=36). The patients were divided into 2 groups according to the BIS value: A normal sedation group (group 1), with a stable BIS value at 40-60, and a deep sedation group (group 2), with a BIS value rocuronium (0.3, 0.6, 0.9 and 1.2 mg/kg). Tracheal intubation was performed after 2 min of rocuronium administration. BIS, electromyography (EMG), heart rate (HR) and mean arterial pressure (MAP) were recorded continuously and averaged over 1 min during baseline (T1), steady state (T2), 2 min after rocuronium infusion (T3), and 0, 2 and 5 min after tracheal intubation. The results demonstrated that HR and MAP decreased significantly at T2 and T3 compared with T1. Following tracheal intubation (L0), HR and MAP significantly increased compared with T2 and T3, and returned to levels similar to those prior to intubation after 5 min. In group 1C and 1D, BIS was significantly decreased at T3 compared with T2; BIS was significantly increased at L0 compared with T3 in group 1A and 1B. EMG at earlier stages of anesthesia was significantly higher compared with other points, and was significantly increased at L0 compared with T3 in group 1A and 1B. These results demonstrated that BIS response may be associated with the dosage of rocuronium in the normal sedation group, although no association was observed with the deep sedation group. Tracheal intubation resulted in marked hemodynamic changes under both normal and deep sedation.

  9. http://www.bioline.org.br/js 104 Penetrating Tracheal Injuries – A ...

    African Journals Online (AJOL)

    jen

    airway and prompt repair is the mainstay of management of penetrating tracheal injuries. Introduction ... tracheal injury was made in the 16th century ... Pearson 7 Harrington8 Sheely9 and Hood10 ..... Ed Am Col Surg (Chicago) .p.391. 12.

  10. Airway injury during emergency transcutaneous airway access: a comparison at cricothyroid and tracheal sites.

    LENUS (Irish Health Repository)

    Salah, Nazar

    2009-12-01

    Oxygenation via the cricothyroid membrane (CTM) may be required in emergencies, but inadvertent tracheal cannulation may occur. In this study, we compared airway injury between the tracheal and CTM sites using different techniques for airway access.

  11. Randomized controlled trial of the Pentax AWS, Glidescope, and Macintosh laryngoscopes in predicted difficult intubation.

    LENUS (Irish Health Repository)

    Malik, M A

    2009-11-01

    The purpose of this study was to determine the potential for the Pentax AWS and the Glidescope to reduce the difficulty of tracheal intubation in patients at increased risk for difficult tracheal intubation, in a randomized, controlled clinical trial.

  12. Congenital Complete Tracheal Ring in a Neonate: A Case Report

    Directory of Open Access Journals (Sweden)

    Esra ARUN ÖZER

    2017-09-01

    Full Text Available Abnormalities of the upper airway tract lead to congenital high airway obstruction and may complicate neonatal airway management in the delivery room. Congenital complete tracheal rings are a rare and unusual tracheal anomaly, usually presenting in the neonate or infant as respiratory distress. The clinical presentation can vary from almost asymptomatic patients to near-fatal airway obstruction. It may exist as an isolated entity, or in association with other congenital malformations, in particular, cardiac anomalies along with vascular rings and pulmonary slings. Other associated anomalies have also been reported, for example, chromosomal anomalies, malformation of other parts of the respiratory tract, esophagus and skeletal systems. Here, we report an extreme case of VACTERL/TACRD association presented with congenital complete tracheal ring, encephalocele, bilateral radial agenesis with absent thumbs, equinovalgus deformity on right foot, low-set ears and micrognathia.

  13. Evaluation of the individual tube current setting in electrocardiogram-gated cardiac computed tomography estimated from plain chest computed tomography using computed tomography automatic exposure control

    International Nuclear Information System (INIS)

    Kishimoto, Junichi; Sakou, Toshio; Ohta, Yasutoshi

    2013-01-01

    The aim of this study was to estimate the tube current on a cardiac computed tomography (CT) from a plain chest CT using CT-automatic exposure control (CT-AEC), to obtain consistent image noise, and to optimize the scan tube current by individualizing the tube current. Sixty-five patients (Group A) underwent cardiac CT at fixed tube current. The mAs value for plain chest CT using CT-AEC (AEC value) and cardiac CT image noise were measured. The tube current needed to obtain the intended level of image noise in the cardiac CT was determined from their correlation. Another 65 patients (Group B) underwent cardiac CT with tube currents individually determined from the AEC value. Image noise was compared among Group A and B. Image noise of cardiac CT in Group B was 24.4±3.1 Hounsfield unit (HU) and was more uniform than in Group A (21.2±6.1 HU). The error with the desired image noise of 25 HU was lower in Group B (2.4%) than in Group A (15.2%). Individualized tube current selection based on AEC value thus provided consistent image noise and a scan tube current optimized for cardiac CT. (author)

  14. Two-piece cryopreserved tracheal allotransplantation: an experimental study.

    Science.gov (United States)

    Iyikesici, Tuncel; Tuncozgur, Bulent; Sanli, Maruf; Isik, Ahmet Feridun; Meteroglu, Fatih; Elbeyli, Levent

    2009-10-01

    For successful reconstruction with tracheal allotransplants following long tracheal resections, problems related to the preservation and vascularisation of the tracheal graft have to be solved. In this study, instead of using a long-segment single-piece graft, we used a graft that has been split into two. The aim was to use this graft after cryopreservation in order to ease neo-vascularisation and to maintain tracheal integrity by transplanting it to two separate regions of the dog cervical trachea. This experimental study was conducted in animal laboratories of the medical school on 11 half-blood dogs. The trachea obtained from the first dog was 8 cm in length; it was split into two pieces of 4 cm each and stored in the preservation solution at -80 degrees C for 4 weeks. Following this, the dog was sacrificed. Two 2 cm portions of cervical trachea were excised from the second dog. These parts were then reconstructed with two tracheal grafts of the same length as the cryopreserved ones. Ten dogs that were grouped into five groups of two dogs each underwent the same procedure. The subjects had a bronchoscopic evaluation on the third postoperative week. Anastomosis regions of the test tracheas were resected to be examined histopathologically. Seven subjects were found to have third-degree obstructions during bronchoscopy; two had close to fourth-degree obstructions. In the histopathological examination, contrary to the findings of the bronchoscopies, 75% of the anastomoses had intact epithelium. The cartilage was seen to have well-preserved structural characteristics in all the anastomoses. Twelve anastomoses had moderate, seven mild and one had severe inflammation. All anastomoses had either good or very good level of vascularisation. The integrity of the tracheal epithelium can be maintained with cryopreservation and split anastomosis technique. The cartilage preserves its structural characteristics despite losing its viability, thereby offering an advantage to

  15. Stent placement for tracheal stenosis in patients with esophageal cancer

    International Nuclear Information System (INIS)

    Takagi, Keigo; Hata, Yoshinobu; Sasamoto, Shuichi; Takahashi, Shoji; Sato, Fumitomo; Tamaki, Kazuyoshi; Goto, Hidenori; Yuasa, Rena

    2011-01-01

    Tracheal invasion including tracheal bifurcation due to esophageal cancer can sometimes cause serious complications of the airway, but such cases sometimes improve quickly following chemoradiation treatment. The absolute indications for stent replacement in the airway for this disorder and the optimal choice of stent are herein discussed. Between 1992 and 2010, 28 patients with airway stenosis, including 7 patients with esophago-tracheal fistula, were treated by placement of various stents; namely, 12 patients received Dumon stents, 3 patients had Dynamic stents, 10 patients were given Ultraflex stents, while 3 other patients were treated without the use of stents. Severe dyspnea in the supine position was observed, which mainly originated from invasion to the membranous portion of the trachea. Airway patency was maintained after stent replacement, although the median survival time of such cases was only 4 months. Three patients with severe dyspnea who could lie in a supine position recovered after undergoing chemoradiation treatment without stent replacement. No cases of stent removal were observed after chemoradiation treatment. Chemoradiation treatment for esophageal cancer was found to be effective for the management of airway disturbances, and thus the absolute indications for stent replacement are restricted to patients who cannot lie in a supine position due to severe impairment of ventilation during radiation therapy, as well as patients presenting with tracheobroncho-esophageal fistula. Concerning stent selection, a metal stent should be the first choice for tracheal stenosis due to its ease of insertion, because there is no substantial difference between silicone and metal stents regarding the treatment of tracheal stenosis. However, it is important to note that a silicone Y stent is useful for the treatment of tracheal bifurcation. (author)

  16. Surgery for postintubation tracheal and tracheosubglottic stenotic lesions

    International Nuclear Information System (INIS)

    Ashour, M.; Al-Kattan, K.; Rafay, M.A.; El-Bakry, A.K.; El-Dawlatly, A.; Naguib, M.; Seraj, M.; Joharjy, I.; Al-Serhani, A.

    1996-01-01

    Postintubation tracheal stenosis is a recognized problem. Although its incidence has recently decreased, it is still a difficult complication to treat. We have reviewed our experience with 10 patients with tracheal stenosis over the last five years between 1990 and 1995. There were seven male and three female patients with an average age of 14.2+-4 years (range 6 to 48 years). Resection and reconstruction with primary anastomosis was performed in seven patients, while conservative treatment with dilation was performed in two patients. One patient refused surgery. Operations performed included resection of tracheocricoid segment with tracheothyroid anastomosis (N=3) and tracheal resection with end-to-end anastomosis (N=4). The resected airway ranged from 3 cm to 6 cm. In view of the intense inflammatory and fibrotic process in and around stenotic segment, the practice of tracheostomy for the relief of postintubation acute tracheal obstruction should not be taken lightly, as it adds not only to the severity of the inflammatory process, but also increases the length of the tracheal segment to be resected. Postoperatively, all patients were extubated; this was accomplished by the end of surgery in six patients, while the seventh patient was extubated three weeks later. There was no mortality in this series. When normal functional activity and airway patency were taken as two parameters to judge the outcome of the surgery, results were good in six (86%) patients and satisfactory in one. These results support the validity of the one-stage reconstruction approach as one alternative for the treatment of postintubation tracheal and tracheosubglottic stenotic lesions. (author)

  17. Epigenetic profiles in children with a neural tube defect; a case-control study in two populations.

    Directory of Open Access Journals (Sweden)

    Lisette Stolk

    Full Text Available Folate deficiency is implicated in the causation of neural tube defects (NTDs. The preventive effect of periconceptional folic acid supplement use is partially explained by the treatment of a deranged folate-dependent one carbon metabolism, which provides methyl groups for DNA-methylation as an epigenetic mechanism. Here, we hypothesize that variations in DNA-methylation of genes implicated in the development of NTDs and embryonic growth are part of the underlying mechanism. In 48 children with a neural tube defect and 62 controls from a Dutch case-control study and 34 children with a neural tube defect and 78 controls from a Texan case-control study, we measured the DNA-methylation levels of imprinted candidate genes (IGF2-DMR, H19, KCNQ1OT1 and non-imprinted genes (the LEKR/CCNL gene region associated with birth weight, and MTHFR and VANGL1 associated with NTD. We used the MassARRAY EpiTYPER assay from Sequenom for the assessment of DNA-methylation. Linear mixed model analysis was used to estimate associations between DNA-methylation levels of the genes and a neural tube defect. In the Dutch study group, but not in the Texan study group we found a significant association between the risk of having an NTD and DNA methylation levels of MTHFR (absolute decrease in methylation of -0.33% in cases, P-value = 0.001, and LEKR/CCNL (absolute increase in methylation: 1.36% in cases, P-value = 0.048, and a borderline significant association for VANGL (absolute increase in methylation: 0.17% in cases, P-value = 0.063. Only the association between MTHFR and NTD-risk remained significant after multiple testing correction. The associations in the Dutch study were not replicated in the Texan study. We conclude that the associations between NTDs and the methylation of the MTHFR gene, and maybe VANGL and LEKKR/CNNL, are in line with previous studies showing polymorphisms in the same genes in association with NTDs and embryonic development

  18. Tracheal dimness as a sign of mediastinal pathology

    International Nuclear Information System (INIS)

    Schiavon, F.; Nardini, S.; Giannico, S.

    1987-01-01

    Some cases of mediastinal pathology in which the only pathological pattern was a dimness of the tracheal transparency are described. This sign is not described in previous report and is described as a short break in the aerial tracheogram as seen on the frontal roentgenograph. This sign is produced by an increase in the structures outside the trachea or by a decrease in the air column inside the trachea. Conventional and CT anatomic findings which account for the sign are discussed. A short review of the normal causes of tracheal dimness is presented. This sign may be useful expecially in emergency radiology, since it provides additional information to a simple routine chest roentgenograph

  19. Tracheal Atresia with Segmental Esophageal Duplication: An Unusual Anatomic Arrangement.

    Science.gov (United States)

    Gaerty, Kirsten; Thomas, Joseph T; Petersen, Scott; Tan, Edwin; Kumar, Sailesh; Gardener, Glenn; Armes, Jane

    2016-01-01

    An unusual anatomic configuration of segmental tracheal agenesis/atresia with esophageal duplication on autopsy in a fetus that demised in utero at 29 weeks is reported. The mother was scanned initially for a cardiac anomaly at 20 weeks and on follow-up scan at 27 weeks had polyhydramnios and underwent amnioreduction. The final autopsy diagnosis was vertebral, ano-rectal, cardiac, tracheoesophageal, renal, and limb malformations (VACTERL). We discuss the autopsy findings along with the embryological mechanisms and compare the configuration with Floyd's classification for tracheal agenesis. The difficulties in prenatal diagnosis are discussed.

  20. A new retrograde transillumination technique for videolaryngoscopic tracheal intubation

    DEFF Research Database (Denmark)

    Biro, P; Fried, E; Schlaepfer, M

    2018-01-01

    This single-centre, prospective trial was designed to assess the efficacy of a new retrograde transillumination device called the 'Infrared Red Intubation System' (IRRIS) to aid videolaryngoscopic tracheal intubation. We included 40 adult patients, who were undergoing elective urological surgery......-10])), credibility (10 (8-10 [5-10])) and ease of use (10 (9-10 [8-10])). Tracheal intubation with the system lasted 26 (16-32 [6-89]) s. No alternative technique of securing the airway was necessary. The lowest SpO2 during intubation was 98 (97-99 [91-100])%. We conclude that this method of retrograde...

  1. Congenital tracheal defects: embryonic development and animal models

    Directory of Open Access Journals (Sweden)

    Zenab Arooj Sher

    2016-03-01

    Full Text Available Tracheal anomalies are potentially catastrophic congenital defects. As a newborn begins to breathe, the trachea needs to maintain an appropriate balance of elasticity and rigidity. If the tracheal cartilages are disorganized or structurally weak, the airways can collapse, obstructing breathing. Cartilage rings that are too small or too rigid can also obstruct breathing. These anomalies are frequently associated with craniofacial syndromes, and, despite the importance, are poorly understood. In this review, we summarize the spectrum of pathological phenotypes of the trachea and correlate them with the molecular events uncovered in mouse models.

  2. Tracheal adenoid cystic carcinoma masquerading asthma: A case report

    Directory of Open Access Journals (Sweden)

    Kurul Cuneyt

    2004-10-01

    Full Text Available Abstract Background Tracheal tumors are often misdiagnosed as asthma and are treated with inhaled steroids and bronchodilators without resolution. Case Presentation Here, a patient with tracheal adenoid cystic carcinoma who had been previously diagnosed with difficult asthma was reported. The possibility of the presence of localized airway obstruction was raised when the flow-volume curve suggesting fixed airway obstruction, was obtained. Conclusion The presenting case report emphasizes the fact that not all wheezes are asthma. It is critical to bear in mind that if a patient does not respond to appropriate anti-asthma therapy, localized obstructions should be ruled out before establishing the diagnosis of asthma.

  3. Inhibiting CXCL12 blocks fibrocyte migration and differentiation and attenuates bronchiolitis obliterans in a murine heterotopic tracheal transplant model.

    Science.gov (United States)

    Harris, David A; Zhao, Yunge; LaPar, Damien J; Emaminia, Abbas; Steidle, John F; Stoler, Mark; Linden, Joel; Kron, Irving L; Lau, Christine L

    2013-03-01

    Fibrocytes are integral in the development of fibroproliferative disease after lung transplantation. Undifferentiated fibrocytes (CD45+anti-collagen 1+CXCR4+) preferentially traffic by way of the CXCR4/CXCL12 axis and differentiate into smooth muscle actin-producing (CD45+CXCR4+α-smooth muscle actin+) cells. We postulated that an antibody directed against CXCL12 would attenuate fibrocyte migration and fibro-obliteration of heterotopic tracheal transplant allografts. A total alloantigenic mismatch murine heterotopic tracheal transplant model of obliterative bronchiolitis was used. The mice were treated with either goat-anti-human CXCL12 F(ab')(2) or goat IgG F(ab')(2). Buffy coat, bone marrow, and trachea allografts were collected and analyzed using flow cytometry. Tracheal luminal obliteration was assessed using hematoxylin-eosin and Direct Red 80 collagen stain. Compared with the controls, the anti-CXCL12-treated mice showed a significant decrease in tracheal allograft fibrocyte populations at 7 and 21 days after transplantation. Bone marrow and buffy coat aspirates showed the same trend at 7 days. In the anti-CXCL12-treated mice, there was a 35% decrease in luminal obliteration at 21 days (65% vs 100% obliterated; interquartile range, 38% vs 10%; P = .010) and decreased luminal collagen deposition at 21 and 28 days after transplantation (P = .042 and P = .012, respectively). Understanding the role of fibrocytes in airway fibrosis after lung transplantation could lead to a paradigm shift in treatment strategy. Anti-CXCL12 antibody afforded protection against infiltrating fibrocytes and reduced the deterioration of the tracheal allografts. Thus, the CXCR4/CXCL12 axis is a novel target for the treatment of fibro-obliteration after lung transplantation, and the quantification of fibrocyte populations could provide clinicians with a biomarker of fibrosis, allowing individualized drug therapy. Copyright © 2013 The American Association for Thoracic Surgery. Published

  4. Airflow in Tracheobronchial Tree of Subjects with Tracheal Bronchus Simulated Using CT Image Based Models and CFD Method.

    Science.gov (United States)

    Qi, Shouliang; Zhang, Baihua; Yue, Yong; Shen, Jing; Teng, Yueyang; Qian, Wei; Wu, Jianlin

    2018-03-01

    Tracheal Bronchus (TB) is a rare congenital anomaly characterized by the presence of an abnormal bronchus originating from the trachea or main bronchi and directed toward the upper lobe. The airflow pattern in tracheobronchial trees of TB subjects is critical, but has not been systemically studied. This study proposes to simulate the airflow using CT image based models and the computational fluid dynamics (CFD) method. Six TB subjects and three health controls (HC) are included. After the geometric model of tracheobronchial tree is extracted from CT images, the spatial distribution of velocity, wall pressure, wall shear stress (WSS) is obtained through CFD simulation, and the lobar distribution of air, flow pattern and global pressure drop are investigated. Compared with HC subjects, the main bronchus angle of TB subjects and the variation of volume are large, while the cross-sectional growth rate is small. High airflow velocity, wall pressure, and WSS are observed locally at the tracheal bronchus, but the global patterns of these measures are still similar to those of HC. The ratio of airflow into the tracheal bronchus accounts for 6.6-15.6% of the inhaled airflow, decreasing the ratio to the right upper lobe from 15.7-21.4% (HC) to 4.9-13.6%. The air into tracheal bronchus originates from the right dorsal near-wall region of the trachea. Tracheal bronchus does not change the global pressure drop which is dependent on multiple variables. Though the tracheobronchial trees of TB subjects present individualized features, several commonalities on the structural and airflow characteristics can be revealed. The observed local alternations might provide new insight into the reason of recurrent local infections, cough and acute respiratory distress related to TB.

  5. Nonlinear dynamic analysis and robust controller design for Francis hydraulic turbine regulating system with a straight-tube surge tank

    Science.gov (United States)

    Liang, Ji; Yuan, Xiaohui; Yuan, Yanbin; Chen, Zhihuan; Li, Yuanzheng

    2017-02-01

    The safety and stability of hydraulic turbine regulating system (HTRS) in hydropower plants become increasingly important since the rapid development and the broad application of hydro energy technology. In this paper, a novel mathematical model of Francis hydraulic turbine regulating system with a straight-tube surge tank based on a few state-space equations is introduced to study the dynamic behaviors of the HTRS system, where the existence of possible unstable oscillations of this model is studied extensively and presented in the forms of the bifurcation diagram, time waveform plot, phase trajectories, and power spectrum. To eliminate these undesirable behaviors, a specified fuzzy sliding mode controller is designed. In this hybrid controller, the sliding mode control law makes full use of the proposed model to guarantee the robust control in the presence of system uncertainties, while the fuzzy system is applied to approximate the proper gains of the switching control in sliding mode technique to reduce the chattering effect, and particle swarm optimization is developed to search the optimal gains of the controller. Numerical simulations are presented to verify the effectiveness of the designed controller, and the results show that the performances of the nonlinear HTRS system assisted with the proposed controller is much better than that with the commonly used optimal PID controller.

  6. Human factors related to time-dependent infection control measures: "Scrub the hub" for venous catheters and feeding tubes.

    Science.gov (United States)

    Caspari, Lindsay; Epstein, Elizabeth; Blackman, Amy; Jin, Li; Kaufman, David A

    2017-06-01

    The use of catheter hub decontamination protocols is a common practice to reduce central line-associated bloodstream infections. However, few data exist on the most effective disinfection procedure prior to hub access accounting for human factors and time-dependent practices in real time in the clinical setting. An observational design with a multimodal intervention was used in this study in a neonatal intensive care unit. Direct observations on nurse compliance of scrub times with decontamination when accessing of venous catheter and feeding tube hubs were conducted during 3 phases: (1) baseline period prior to any interventions; (2) during an educational intervention phase; and (3) during a timer intervention period when using a timing device, either an actual timer or music button. Overall, both education and the timing device interventions increased the mean scrub time ± SD of venous catheter hubs. Mean baseline scrub times of 10 ± 5 seconds were lower compared with 23 ± 12 seconds after educational intervention (P music button use (P observed with scrub times of feeding tubes. Time-based infection control measures, such as scrubbing the hub, must be implemented with aids that qualify specific times to account for human factors, to ensure adherence to time-dependent measures aimed at decreasing nosocomial infections. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Tracheoesophageal Fistula due to a Damaged Tracheal Stent

    Directory of Open Access Journals (Sweden)

    Masahiro Kimura

    2014-01-01

    Full Text Available We describe the management of a tracheoesophageal fistula due to a damaged tracheal stent, which was first inserted to treat tracheal stenosis. A 29-year-old woman with a history of treated epilepsy had a seizure and suffered from smoke inhalation during a fire. Breathing difficulties appeared and gradually worsened; consultation was obtained two years afterward. After undergoing a thorough examination, the patient was diagnosed with tracheal strangulation. A noncovered, metallic stent was inserted. When the patient was 37 years old, she was admitted to our hospital for the treatment of a tracheoesophageal fistula. We diagnosed it as a tracheoesophageal fistula due to the collapse of the damaged tracheal stent toward the esophageal side, and we decided to perform a mediastinal tracheostomy. Granulation may be formed in the circumference of a stent that has been present for a prolonged period, and removal of the stent may become difficult. This case suggests that insertion of a noncovered, metallic stent is contraindicated for a benign disease.

  8. Tubeless tracheal resection and reconstruction for management of benign stenosis.

    Science.gov (United States)

    Caronia, Francesco Paolo; Loizzi, Domenico; Nicolosi, Tommaso; Castorina, Sergio; Fiorelli, Alfonso

    2017-12-01

    We reported a tubeless tracheal resection and reconstruction for the management of benign posttracheostomy tracheal stenosis. A 34-year-old man with stridor, severe respiratory distress, and recurrent pneumonia was referred to our attention for treatment of benign posttracheostomy tracheal stenosis. As he refused general anesthesia, the procedure was performed while he was under local anesthesia and spontaneous ventilation. Sedation was started with infusion of dexmedetomidine 0.7 mg/kg/min and of remifentanil 0.5 mg/kg/h; also, 40%-50% oxygen was delivered using a laryngeal mask at a rate of 3.5 mL/min. An additional dose of 2% lidocaine was injected into the surgical site during the operation to achieve an adequate level of anesthesia. A standard resection and reconstruction of trachea was carried out and no recurrence was found in the follow-up of 41 months. Tubeless tracheal surgery seems to be a feasible and safe procedure. Larger prospective series should validate our results. © 2017 Wiley Periodicals, Inc.

  9. The relationships between tracheal index and lung volume parameters in mild-to-moderate COPD

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Jung Seop, E-mail: ejs00@hanmail.net [Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Lee, Geewon, E-mail: rabkingdom@naver.com [Department of Radiology, Pusan National University Hospital, 179 Gudeok-ro, Seo-gu, Busan 602-739 (Korea, Republic of); Lee, Ho Yun, E-mail: hoyunlee96@gmail.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Oh, Jin Young, E-mail: indr71@hanmail.net [Division of Pulmonology, Department of Internal Medicine, Dongguk University Ilsan Medical Center, 814 Siksa-dong, Ilsandong-gu, Goyang-si, Gyeonggi-do 410-773 (Korea, Republic of); Woo, Sook-young, E-mail: sookyoung12.woo@samsung.com [Biostatistics Team, Samsung Biomedical Research Institute, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Jeon, Kyeongman, E-mail: kjeon@skku.edu [Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Um, Sang-Won, E-mail: sangwonum@skku.edu [Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Koh, Won-Jung, E-mail: wjkoh@skku.edu [Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); Suh, Gee Young, E-mail: suhgy@skku.edu [Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 135-710 (Korea, Republic of); and others

    2013-12-01

    Background: Although elongated morphological changes in the trachea are known to be related to lung function in chronic obstructive pulmonary disease (COPD), whether the tracheal morphological changes are associated with airflow limitations or overinflation of the lung in the early stages of COPD has not yet been determined. Thus, our aim was to investigate the association of tracheal index (TI) with lung function parameters, including lung volume parameters, in COPD patients with mild-to-moderate airflow limitations. Materials and methods: A retrospective study was conducted in 193 COPD patients with GOLD grades 1–2 (post-bronchodilator forced expiratory volume in 1 s [FEV{sub 1}] ≥ 50% predicted with FEV{sub 1}/forced vital capacity ratio ≤ 70%; age range, 40–81) and 193 age- and gender-matched subjects with normal lung function as a control group (age range, 40–82). Two independent observers measured TI at three anatomical levels on chest radiographs and CT scans. Results: Compared with the control group, TI was reduced significantly and “saber-sheath trachea” was observed more frequently in COPD patients. Patients with GOLD grade 2 disease had a lower TI than those with GOLD grade 1. TI had apparent inverse correlations with total lung capacity, functional residual capacity, and residual volume, regardless of the anatomical level of the trachea. Even after adjustments for covariates, this association persisted. Conclusions: TI is reduced even in mild-to-moderate COPD patients, and TI measured on chest CT shows significant inverse relationships with all lung volume parameters assessed, suggesting that tracheal morphology may change during the early stages of COPD.

  10. The relationships between tracheal index and lung volume parameters in mild-to-moderate COPD

    International Nuclear Information System (INIS)

    Eom, Jung Seop; Lee, Geewon; Lee, Ho Yun; Oh, Jin Young; Woo, Sook-young; Jeon, Kyeongman; Um, Sang-Won; Koh, Won-Jung; Suh, Gee Young

    2013-01-01

    Background: Although elongated morphological changes in the trachea are known to be related to lung function in chronic obstructive pulmonary disease (COPD), whether the tracheal morphological changes are associated with airflow limitations or overinflation of the lung in the early stages of COPD has not yet been determined. Thus, our aim was to investigate the association of tracheal index (TI) with lung function parameters, including lung volume parameters, in COPD patients with mild-to-moderate airflow limitations. Materials and methods: A retrospective study was conducted in 193 COPD patients with GOLD grades 1–2 (post-bronchodilator forced expiratory volume in 1 s [FEV 1 ] ≥ 50% predicted with FEV 1 /forced vital capacity ratio ≤ 70%; age range, 40–81) and 193 age- and gender-matched subjects with normal lung function as a control group (age range, 40–82). Two independent observers measured TI at three anatomical levels on chest radiographs and CT scans. Results: Compared with the control group, TI was reduced significantly and “saber-sheath trachea” was observed more frequently in COPD patients. Patients with GOLD grade 2 disease had a lower TI than those with GOLD grade 1. TI had apparent inverse correlations with total lung capacity, functional residual capacity, and residual volume, regardless of the anatomical level of the trachea. Even after adjustments for covariates, this association persisted. Conclusions: TI is reduced even in mild-to-moderate COPD patients, and TI measured on chest CT shows significant inverse relationships with all lung volume parameters assessed, suggesting that tracheal morphology may change during the early stages of COPD

  11. Nanostructured polypyrrole for automated and electrochemically controlled in-tube solid-phase microextraction of cationic nitrogen compounds

    International Nuclear Information System (INIS)

    Asiabi, Hamid; Yamini, Yadollah; Rezaei, Fatemeh; Seidi, Shahram

    2015-01-01

    The authors describe an efficient method for microextraction and preconcentration of trace quantities of cationic nitrogen compounds, specifically of anilines. It relies on a combination of electrochemically controlled solid-phase microextraction and on-line in-tube solid-phase microextraction (SPME) using polypyrrole-coated capillaries. Nanostructured polypyrrole was electrically deposited on the inner surface of a stainless steel tube and used as the extraction phase. It also acts as a polypyrrole electrode that was used as a cation exchanger, and a platinum electrode that was used as the anode. The solution to be extracted is passed over the inner surface of the polypyrrole electrode, upon which cations are extracted by applying a negative potential under flow conditions. This method represents an ideal technique for SPME of protonated anilines because it is fast, easily automated, solvent-free, and inexpensive. Under optimal conditions, the limits of detection are in the 0.10–0.30 μg L -1 range. The method works in the 0.10 to 300 μg L -1 concentration range. The inter- and intra-assay precisions (RSD%; for n = 3) range from 5.1 to 7.5 % and from 4.7 to 6.0 % at the concentration levels of 2, 10 and 20 μg L -1 , respectively. The EC-in-tube SPME method was successfully applied to the analysis of methyl-, 4-chloro-, 3-chloro and 3,4-dichloroanilines in (spiked) water samples. (author)

  12. [Circular tracheal resection for cicatrical stenosis and functioning tracheostomy].

    Science.gov (United States)

    Parshin, V D; Titov, V A; Parshin, V V; Parshin, A V; Berikkhanov, Z; Amangeldiev, D M

    To analyze the results of tracheal resection for cicatricial stenosis depending on the presence of tracheostomy. 1128 patients with tracheal cicatricial stenosis were treated for the period 1963-2015. The first group consisted of 297 patients for the period 1963-2000, the second group - 831 patients for the period 2001-2015. Most of them 684 (60.6%) were young and able-bodied (age from 21 to 50 years). In the first group 139 (46.8%) out of 297 patients had functioning tracheostomy. For the period 2001-2015 tracheostomy was made in 430 (51.7%) out of 831 patients with cicatricial stenosis. Time of cannulation varied from a few weeks to 21 years. Re-tracheostomy within various terms after decanulation was performed in 68 (15.8%) patients. Tracheal resection with anastomosis was performed in 59 and 330 in both groups respectively. At present time these operations are performed more often in view of their standard fashion in everyday practice. In the second group tracheal resection followed by anastomosis was observed in 110 (25.6%) out of 430 patients with tracheostomy that is 4.4 times more often than in previous years. In total 2 patients died after 330 circular tracheal resections within 2001-2015 including one patient with and one patient without tracheostomy. Mortality was 0.6%. Moreover, this value was slightly higher in patients operated with a functioning tracheostomy compared with those without it - 0.9 vs. 0.5% respectively. The causes of death were bleeding into tracheobronchial lumen and pulmonary embolism. The source of bleeding after tracheal resection was innominate artery. Overall incidence of postoperative complications was 2 times higher in tracheostomy patients compared with those without it - 22 (20%) vs. 26 (11.8%) cases respectively. Convalescence may be achieved in 89.8% patients after circular tracheal resection. Adverse long-term results are associated with postoperative complications. So their prevention and treatment will improve the

  13. Implantation of Induced Pluripotent Stem Cell-Derived Tracheal Epithelial Cells.

    Science.gov (United States)

    Ikeda, Masakazu; Imaizumi, Mitsuyoshi; Yoshie, Susumu; Nakamura, Ryosuke; Otsuki, Koshi; Murono, Shigeyuki; Omori, Koichi

    2017-07-01

    Compared with using autologous tissue, the use of artificial materials in the regeneration of tracheal defects is minimally invasive. However, this technique requires early epithelialization on the inner side of the artificial trachea. After differentiation from induced pluripotent stem cells (iPSCs), tracheal epithelial tissues may be used to produce artificial tracheas. Herein, we aimed to demonstrate that after differentiation from fluorescent protein-labeled iPSCs, tracheal epithelial tissues survived in nude rats with tracheal defects. Red fluorescent tdTomato protein was electroporated into mouse iPSCs to produce tdTomato-labeled iPSCs. Embryoid bodies derived from these iPSCs were then cultured in differentiation medium supplemented with growth factors, followed by culture on air-liquid interfaces for further differentiation into tracheal epithelium. The cells were implanted with artificial tracheas into nude rats with tracheal defects on day 26 of cultivation. On day 7 after implantation, the tracheas were exposed and examined histologically. Tracheal epithelial tissue derived from tdTomato-labeled iPSCs survived in the tracheal defects. Moreover, immunochemical analyses showed that differentiated tissues had epithelial structures similar to those of proximal tracheal tissues. After differentiation from iPSCs, tracheal epithelial tissues survived in rat bodies, warranting the use of iPSCs for epithelial regeneration in tracheal defects.

  14. Enhancing DC Glow Discharge Tube Museuum Displays using a Theremin Controlled Helmholtz Coil to Demonstrate Magnetic Confinement

    Science.gov (United States)

    Siu, Theodore; Wissel, Stephanie; Guttadora, Larry; Liao, Susan; Zwicker, Andrew

    2010-11-01

    Since their discovery in the mid 1800's, DC glow discharge apparatuses have commonly been used for spectral analysis, the demonstration of the Frank-Hertz experiment, and to study plasma breakdown voltages following from the Paschen Curve. A DC glow discharge tube museum display was outfitted with a Helmholtz Coil electromagnet in order to demonstrate magnetic confinement for a science museum display. A device commonly known as a ``theremin'' was designed and built in order to externally control the Helmholtz Coil current and the plasma current. Originally a musical instrument, a theremin has two variable capacitors connected to two radio frequency oscillators which determine pitch and volume. Using a theremin to control current and ``play'' the plasma adds appeal and durability by providing a new innovative means of interacting with a museum exhibit. Educationally, students can use the display to not only learn about plasma properties but also electronic properties of the human body.

  15. Estimating patient dose from CT exams that use automatic exposure control: Development and validation of methods to accurately estimate tube current values.

    Science.gov (United States)

    McMillan, Kyle; Bostani, Maryam; Cagnon, Christopher H; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H; McNitt-Gray, Michael F

    2017-08-01

    The vast majority of body CT exams are performed with automatic exposure control (AEC), which adapts the mean tube current to the patient size and modulates the tube current either angularly, longitudinally or both. However, most radiation dose estimation tools are based on fixed tube current scans. Accurate estimates of patient dose from AEC scans require knowledge of the tube current values, which is usually unavailable. The purpose of this work was to develop and validate methods to accurately estimate the tube current values prescribed by one manufacturer's AEC system to enable accurate estimates of patient dose. Methods were developed that took into account available patient attenuation information, user selected image quality reference parameters and x-ray system limits to estimate tube current values for patient scans. Methods consistent with AAPM Report 220 were developed that used patient attenuation data that were: (a) supplied by the manufacturer in the CT localizer radiograph and (b) based on a simulated CT localizer radiograph derived from image data. For comparison, actual tube current values were extracted from the projection data of each patient. Validation of each approach was based on data collected from 40 pediatric and adult patients who received clinically indicated chest (n = 20) and abdomen/pelvis (n = 20) scans on a 64 slice multidetector row CT (Sensation 64, Siemens Healthcare, Forchheim, Germany). For each patient dataset, the following were collected with Institutional Review Board (IRB) approval: (a) projection data containing actual tube current values at each projection view, (b) CT localizer radiograph (topogram) and (c) reconstructed image data. Tube current values were estimated based on the actual topogram (actual-topo) as well as the simulated topogram based on image data (sim-topo). Each of these was compared to the actual tube current values from the patient scan. In addition, to assess the accuracy of each method in estimating

  16. Control chart analysis of data regarding 0.2% yield strength (YS) and percent total circumferential elongation (%TCE) for zircaloy clad tubes for PHWR and BWR fuels

    International Nuclear Information System (INIS)

    Yadav, M.B.; Singh, Hari; Vaidyanathan, S.; Sood, D.D.; Raghavan, S.V.; Bandyopadhyay, A.K.; Kulkarni, P.G.

    1992-01-01

    Zircaloy cladding tubes for PHWR and BWR fuels are manufactured and tested at Nuclear Fuel Complex (NFC), Hyderabad. Atomic Fuels Division is carrying out the quality assurance of the fuels on behalf of Nuclear Power Corporation (NPC). In this paper an attempt has been made to assess whether the quality of the clad tubes has met the requirements specified for the two mechanical properties of the tubes namely 0.2% yield strength and percent total circumferential elongation using control chart technique. For this purpose data for about 100 lots in each case were used. Process means and process standard deviations for these properties and the control limits for the corresponding control charts were estimated. The main findings are: (i) In case of PHWR tubes the production quality level with respect to 0.2% YS is higher, while that in case of %TCE is lower causing rejection of lots. On the other hand in the case of BWR tubes the production quality levels with respect to both the properties are higher than the required one. (ii) With respect to 0.2% YS, in case of BWR tubes a change in the pattern of distribution is detected beyond the lot serial no.47. However in case of PHWR tubes, though the data falls into two groups, no such pattern is seen. A modification in the acceptance/rejection criterion of the lot has been suggested. It is also pointed out that to have a correct picture of the total variation it is necessary to study the within tube variation. (author). 4 figs, 2 tabs

  17. Pressure tube reactor

    International Nuclear Information System (INIS)

    Susuki, Akira; Murata, Shigeto; Minato, Akihiko.

    1993-01-01

    In a pressure tube reactor, a reactor core is constituted by arranging more than two units of a minimum unit combination of a moderator sealing pipe containing a calandria tube having moderators there between and a calandria tube and moderators. The upper header and a lower header of the calandria tank containing moderators are communicated by way of the moderator sealing tube. Further, a gravitationally dropping mechanism is disposed for injecting neutron absorbing liquid to a calandria gas injection portion. A ratio between a moderator volume and a fuel volume is defined as a function of the inner diameter of the moderator sealing tube, the outer diameter of the calandria tube and the diameter of fuel pellets, and has no influence to intervals of a pressure tube lattice. The interval of the pressure tube lattice is enlarged without increasing the size of the pressure tube, to improve production efficiency of the reactor and set a coolant void coefficient more negative, thereby enabling to improve self controllability and safety. Further, the reactor scram can be conducted by injecting neutron absorbing liquid. (N.H.)

  18. Fractured tracheostomy tube – A case report of a 3-year old Ghanaian child

    Directory of Open Access Journals (Sweden)

    Akwasi Antwi-Kusi

    2012-09-01

    Discussion: Fracture of a tracheostomy tube is a rare complication, which should be considered as part of the differential diagnosis in a ventilated patient with a tracheostomy. Wound exploration through the tracheal stoma is an alternative technique that can be adopted in a restricted resource setting.

  19. A preliminary study into performing routine tube output and automatic exposure control quality assurance using radiology information system data

    International Nuclear Information System (INIS)

    Charnock, P.; Jones, R.; Fazakerley, J.; Wilde, R.; Dunn, A. F.

    2011-01-01

    Data are currently being collected from hospital radiology information systems in the North West of the UK for the purposes of both clinical audit and patient dose audit. Could these data also be used to satisfy quality assurance (QA) requirements according to UK guidance? From 2008 to 2009, 731 653 records were submitted from 8 hospitals from the North West England. For automatic exposure control QA, the protocol from Inst. of Physics and Engineering in Medicine (IPEM) report 91 recommends that milli amperes per second can be monitored for repeatability and reproducibility using a suitable phantom, at 70-81 kV. Abdomen AP and chest PA examinations were analysed to find the most common kilo voltage used with these records then used to plot average monthly milli amperes per second with time. IPEM report 91 also recommends that a range of commonly used clinical settings is used to check output reproducibility and repeatability. For each tube, the dose area product values were plotted over time for two most common exposure factor sets. Results show that it is possible to do performance checks of AEC systems; however more work is required to be able to monitor tube output performance. Procedurally, the management system requires work and the benefits to the workflow would need to be demonstrated. (authors)

  20. Effect of non-condensable gas on heat transfer in steam turbine condenser and modelling of ejector pump system by controlling the gas extraction rate through extraction tubes

    International Nuclear Information System (INIS)

    Strušnik, Dušan; Golob, Marjan; Avsec, Jurij

    2016-01-01

    Graphical abstract: Control of the amount of the pumped gases through extraction tubes. The connecting locations interconnect the extraction tubes for STC gas pumping. The extraction tubes are fitted with 3 control valves to control the amount of the pumped gas depending on the temperature of the pumped gas. The amount of the pumped gas increases through the extraction tubes, where the pumped gases are cooler and decreases, at the same time, through the extraction tubes, where the pumped gases are warmer. As a result, pumping of a larger amount of NCG is ensured and of a smaller amount of CG, given that the NCG concentration is the highest on the colder places. This way, the total amount of the pumped gases from the STC can be reduced, the SEPS operates more efficiently and consumes less energy for its operation. - Highlights: • Impact of non-condensable gas on heat transfer in a steam turbine condenser. • The ejector system is optimised by selecting a Laval nozzle diameter. • Simulation model of the control of the amount of pumped gases through extraction tubes. • Neural network and fuzzy logic systems used to control gas extraction rate. • Simulation model was designed by using real process data from the thermal power plant. - Abstract: The paper describes the impact of non-condensable gas (NCG) on heat transfer in a steam turbine condenser (STC) and modelling of the steam ejector pump system (SEPS) by controlling the gas extraction rate through extraction tubes. The ideal connection points for the NCG extraction from the STC are identified by analysing the impact of the NCG on the heat transfer and measuring the existing system at a thermal power plant in Slovenia. A simulation model is designed using the Matlab software and Simulink, Neural Net Work, Fuzzy Logic and Curve Fitting Toolboxes, to control gas extraction rate through extraction tubes of the gas pumped from the STC, thus optimising the operation of the steam ejector pump system (SEPS). The

  1. [Anesthetic management of a patient with Creutzfeldt-Jacob disease undergoing tracheal separation].

    Science.gov (United States)

    Kanzaki, Rieko; Hamada, Hiroshi; Fukuda, Hideki; Kawamoto, Masashi

    2012-10-01

    We gave anesthesia for tracheal separation in a patient with Creutzfeldt-Jakob disease. The patient, a 33-year-old woman, was bedridden and unable to communicate, and was going to undergo a tracheal separation procedure for repeated bouts of aspiration pneumonia. After a tracheostomy with local anesthesia and sedation with propofol, general anesthesia was induced and maintained with propofol (1.5-3.0 microg x ml(-1), target controlled infusion) and remifentanil (0.05-0.15 microg x kg(-1) x min(-1)). We did not use an anesthetic apparatus from the standpoint of infection control, and provided manual ventilation with a disposable Jackson-Rees circuit. During the operation, an entropy monitor indicated alternating extremely low (0-10) and high (90-100) values without circulatory change, probably due to a previously existing electroencephalographic abnormality. The surgery was uneventful, and spontaneous breathing and eyelid opening occurred about 10 minutes after discontinuation of remifentanil and propofol. In such infected patients, abnormal prion proteins can exist outside of the central nervous system throughout the period of anesthetic management. Therefore, careful infection control must be undertaken, even if the surgical site is not directly related to the central nervous system.

  2. New CO2 laser waveguide systems: advances in surgery of tracheal stenosis

    Science.gov (United States)

    Stasche, Norbert; Bernecker, Frank; Hoermann, Karl

    1996-01-01

    The carbon dioxide laser is a well established tool in the surgical treatment of laryngeal and tracheal stenosis. Usually the laser beam is applied by a microscope/micromanipulator device. Different types of rigid laryngoscopes and bronchoscopes provide access to nearly every area of larynx, trachea and main bronchi. In order to be treated with this equipment the target tissue has to be in a straight optical axis with the laser beam output at the micromanipulator. We report about one patient who presented with severe dyspnea due to granulation tissue directly below his left vocal cord. He was suffering from tracheomalacia for several years and was successfully treated by tracheostomy and a Montgomery's silicone T-tube as a stent. Then granulation tissue blocked the upper orifice of the Montgomery's T-tube. First removal by a carbon dioxide laser beam through the laryngoscope would have required sacrificing his intact left vocal cord. We removed the obstructing tissue by using the ArthroLaseTM System: the carbon dioxide laser beam was conducted through a 90 degree bent rigid probe, using the tracheostomy as an access. This ArthroLaseTM System was originally designed for arthroscopic surgery. In this special case however it successfully extends the use of the carbon dioxide laser in otolaryngology.

  3. Microstructure control of Zr-Nb-Sn alloy with Mo addition for HWR pressure tube application

    International Nuclear Information System (INIS)

    Hwang, S. K.; Kim, M. H.; Kim, J. H.; Kwon, S. I.; Kim, Y. S.

    1997-01-01

    As a basic research to develop the material for heavy water reactor pressure tube application the effect of Mo addition to Zr-Nb-Sn alloy was studied for the purpose of minimizing the amount of cold working while maintaining a high strength. To select the target alloy system we first designed various alloy compositions and chose Zr-Nb-Sn and Zr-Nb-Mo through multi-regression analysis of the relationship between the basic properties and the compositions. Plasma arc melting was used to produce the alloys and the microstructure change introduced by the processing steps including hot forging, beta-heat treatment, hot rolling, cold rolling and recrystallization heat treatment was investigated. Recrystallization of Zr-Nb-Sn was retarded by adding Mo and this resulted in a fine grain structure in Zr-Nb-Sn-Mo alloy. Beside the retarding effect recrystallization, Mo increased the amount of residual beta phase and showed an indication of precipitation hardening, which added up to the possibility of applying the alloy for the desired usage. (author)

  4. A high-precision X-ray tomograph for quality control of the ATLAS Muon Monitored Drift Tube Chambers

    CERN Document Server

    Schuh, S; Banhidi, Z; Fabjan, Christian Wolfgang; Lampl, W; Marchesotti, M; Rangod, Stephane; Sbrissa, E; Smirnov, Y; Voss, Rüdiger; Woudstra, M; Zhuravlov, V

    2004-01-01

    A dedicated X-ray tomograph has been developed at CERN to control the required wire placement accuracy of better than 20mum of the 1200 Monitored Drift Tube Chambers which make up most of the precision chamber part of the ATLAS Muon Spectrometer. The tomograph allows the chamber wire positions to be measured with a 2mum statistical and 2mum systematic uncertainty over the full chamber cross-section of 2.2 multiplied by 0.6m**2. Consistent chamber production quality over the 4-year construction phase is ensured with a similar to 15% sampling rate. Measurements of about 70 of the 650 MDT chambers so far produced have been essential in assessing the validity and consistency of the various construction procedures.

  5. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  6. A fast position estimation method for a control rod guide tube inspection robot with a single camera

    International Nuclear Information System (INIS)

    Lee, Jae C.; Seop, Jun H.; Choi, Yu R.; Kim, Jae H.

    2004-01-01

    One of the problems in the inspection of control rod guide tubes using a mobile robot is accurate estimation of the robot's position. The problem is usually explained by the question 'Where am I?'. We can solve this question by a method called dead reckoning using odometers. But it has some inherent drawbacks such that the position error grows without bound unless an independent reference is used periodically to reduce the errors. In this paper, we presented one method to overcome this drawback by using a vision sensor. Our method is based on the classical Lucas Kanade algorithm for on image tracking. In this algorithm, an optical flow must be calculated at every image frame, thus it has intensive computing load. In order to handle large motions, it is preferable to use a large integration window. But a small integration window is more preferable to keep the details contained in the images. We used the robot's movement information obtained from the dead reckoning as an input parameter for the feature tracking algorithm in order to restrict the position of an integration window. By means of this method, we could reduce the size of an integration window without any loss of its ability to handle large motions and could avoid the trade off in the accuracy. And we could estimate the position of our robot relatively fast without on intensive computing time and the inherent drawbacks mentioned above. We studied this algorithm for applying it to the control rod guide tubes inspection robot and tried an inspection without on operator's intervention

  7. Method for selecting recurrent controls of the tubes and components of the process systems

    International Nuclear Information System (INIS)

    Oehlin, L.

    1987-01-01

    The existing rules and recommendations for the inspection of the components of nuclear power plants are considered inadequate. Therefore some new directions have been worked out for suitable distribution of controlling actions. The new concept will cover the probability of fractures and the consequences of accidents. Control procedures will stress safety aspects in particular. (G.B)

  8. Model Based Controller Design for a Shell and Tube Heat Exchanger

    Directory of Open Access Journals (Sweden)

    S. Nithya

    2007-10-01

    Full Text Available In all the process industries the process variables like flow, pressure, level and temperature are the main parameters that need to be controlled in both set point and load changes. The transfer of heat is one of the main important operation in the heat exchanger .The transfer of heat may be fluid to fluid, gas to gas i.e. in the same phase or the phase change can occur on either side of the heat exchanger. The control of heat exchanger is complex due to its nonlinear dynamics. For this nonlinear process of a heat exchanger the model is identified to be First Order plus Dead Time (FOPDT.The Internal Model Control (IMC is one of the model predictive control methods based on the predictive output of the process model. The conventional controller tuning is compared with IMC techniques and it found to be suitable for heat exchanger than the conventional PI tuning.

  9. Effect of aging on tracheal mucociliary clearance in Beagle dogs

    International Nuclear Information System (INIS)

    Whaley, S.L.; Muggenburg, B.A.; Wolff, R.K.

    1985-01-01

    Tracheal mucous velocity measurements were made in 24 Beagle dogs, in 5 age groups, using a gamma camera to detect movement on instilled radiolabeled material. Age groups were defined as immature, young adult, middle-aged, mature, and aged dogs. Mean velocities (+/- SE) were 3.6 +/- 0.4 mm/min in the immature dogs, 9.8 +/- 0.7 mm/min in the young adults, 6.9 +/- 0.5 mm/min in the middle-aged dogs, 3.6 +/- 1.1 mm/min in the mature dogs, and 2.8 +/- 0.6 mm/min in the aged dogs. Tracheal mucous velocity was significantly faster in the young adult and middle-aged groups than in the immature, mature, and aged dog groups. 4 references, 1 figure, 1 table

  10. Transoral tracheal intubation of rodents using a fiberoptic laryngoscope.

    Science.gov (United States)

    Costa, D L; Lehmann, J R; Harold, W M; Drew, R T

    1986-06-01

    A fiberoptic laryngoscope which allows direct visualization of the deep pharynx and epiglottis has been developed for transoral tracheal intubation of small laboratory mammals. The device has been employed in the intubation and instillation of a variety of substances into the lungs of rats, and with minor modification, has had similar application in mice, hamsters, and guinea pigs. The simplicity and ease of handling of the laryngoscope permits one person to intubate large numbers of enflurane anesthetized animals either on an open counter top or in a glove-box, as may be required for administration of carcinogenic materials. Instillation of 7Be-labeled carbon particles into the lungs of mice, hamsters, rats, and guinea pigs resulted in reasonably consistent interlobal distribution of particles for each test animal species with minimal tracheal deposition. However, actual lung tissue doses of carbon exhibited some species dependence.

  11. Difficult Tracheal Intubation in Obese Gastric Bypass patients

    DEFF Research Database (Denmark)

    Dohrn, Niclas; Sommer, Thorbjørn; Bisgaard, J.

    2016-01-01

    Endotracheal intubation is commonly perceived to be more difficult in obese patients than in lean patients. Primarily, we investigated the association between difficult tracheal intubation (DTI) and obesity, and secondarily, the association between DTI and validated scoring systems used to assess...... the airways, the association between DTI and quantities of anesthetics used to induce general anesthesia, and the association between DTI and difficulties with venous and arterial cannulation. This is a monocentric prospective observational clinical study of a consecutive series of 539 obese patients...... was 3.5 % and the patients with DTI were more frequently males, had higher CLC, higher American Society of Anesthesiologists physical status classification (ASA), and noticeably, a lower BMI compared to the patients with easy tracheal intubation. After adjustment with multivariable analyses body mass...

  12. Control and optimization of solute transport in a thin porous tube

    KAUST Repository

    Griffiths, I. M.; Howell, P. D.; Shipley, R. J.

    2013-01-01

    differentials upon the dispersive solute behaviour are investigated. The model is used to explore the control of solute transport across the membrane walls via the membrane permeability, and a parametric expression for the permeability required to generate a

  13. Improved transmission of electrostatic accelerator in a wide range of terminal voltages by controlling the focal strength of entrance acceleration tube

    Science.gov (United States)

    Lobanov, Nikolai R.; Tunningley, Thomas; Linardakis, Peter

    2018-04-01

    Tandem electrostatic accelerators often require the flexibility to operate at a variety of terminal voltages to accommodate various user requirements. However, the ion beam transmission will only be optimal for a limited range of terminal voltages. This paper describes the operational performance of a novel focusing system that expands the range of terminal voltages for optimal transmission. This is accomplished by controlling the gradient of the entrance of the low-energy tube, providing an additional focusing element. In this specific case it is achieved by applying up to 150 kV to the fifth electrode of the first unit of the accelerator tube. Numerical simulations and beam transmission tests have been performed to confirm the effectiveness of the lens. An analytical expression has been derived describing its focal properties. These tests demonstrate that the entrance lens control eliminates the need to short out sections of the tube for operation at low terminal voltage.

  14. Evaluation of App-Based Serious Gaming as a Training Method in Teaching Chest Tube Insertion to Medical Students: Randomized Controlled Trial

    Science.gov (United States)

    Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C

    2018-01-01

    Background The insertion of a chest tube should be as quick and accurate as possible to maximize the benefit and minimize possible complications for the patient. Therefore, comprehensive training and assessment before an emergency situation are essential for proficiency in chest tube insertion. Serious games have become more prevalent in surgical training because they enable students to study and train a procedure independently, and errors made have no effect on patients. However, up-to-date evidence regarding the effect of serious games on performance in procedures in emergency medicine remains scarce. Objective The aim of this study was to investigate the serious gaming approach in teaching medical students an emergency procedure (chest tube insertion) using the app Touch Surgery and a modified objective structural assessment of technical skills (OSATS). Methods In a prospective, rater-blinded, randomized controlled trial, medical students were randomized into two groups: intervention group or control group. Touch Surgery has been established as an innovative and cost-free app for mobile devices. The fully automatic software enables users to train medical procedures and afterwards self-assess their training effort. The module chest tube insertion teaches each key step in the insertion of a chest tube and enables users the meticulous application of a chest tube. In contrast, the module “Thoracocentesis” discusses a basic thoracocentesis. All students attended a lecture regarding chest tube insertion (regular curriculum) and afterwards received a Touch Surgery training lesson: intervention group used the module chest tube insertion and the control group used Thoracocentesis as control training. Participants’ performance in chest tube insertion on a porcine model was rated on-site via blinded face-to-face rating and via video recordings using a modified OSATS tool. Afterwards, every participant received an individual questionnaire for self-evaluation. Here

  15. Treatment of Benign Tracheal Stenosis Using Endoluminal Spray Cryotherapy.

    Science.gov (United States)

    Bhora, Faiz Y; Ayub, Adil; Forleiter, Craig M; Huang, Chyun-Yin; Alshehri, Khalid; Rehmani, Sadiq; Al-Ayoubi, Adnan M; Raad, Wissam; Lebovics, Robert S

    2016-11-01

    Tracheal stenosis is a debilitating disorder with heterogeneity in terms of disease characteristics and management. Repeated recurrences substantially alter patients' quality of life. There is limited evidence for the use of spray cryotherapy (SCT) in the management of benign airway disease. To report our early results for the use of SCT in patients with benign tracheal stenosis. Data were extracted from the medical records of a consecutive series of patients with benign airway stenosis secondary to granulomatosis with polyangiitis (GPA) (n = 13), prior tracheotomy or tracheal intubation (n = 8), and idiopathic strictures (n = 5) treated from September 1, 2013, to September 30, 2015, at a tertiary care hospital. Airway narrowing was quantified on a standard quartile grading scale. Response to treatment was assessed by improvement in airway caliber and the time interval for reintervention. Delivery of 4 5-second SCT cycles and 2 balloon dilatations. Twenty-six patients (median [range] age, 53 [16-83] years; 20 [77%] female) underwent 48 SCT sessions. Spray cryotherapy was successfully used without any substantial intraoperative or postoperative complications in all patients. In a median (range) follow-up of 11 (1-26) months, all patients had improvement in symptoms. Before the institution of SCT, 23 patients (88%) had grade III or IV stenosis. At the last evaluation after induction of SCT, 4 (15%) had grade III or IV stenosis, with a mean (SD) change of 1.39 (0.51) (P benign tracheal stenosis. Although efficacy evidence is limited for SCT, it may be useful for patients who have experienced treatment failure with conventional modalities. Further analysis of this cohort will determine the physiologic durability of the reported short-term changes. Additional trials are warranted for further evaluation of this modality.

  16. Mucus glycoprotein secretion by tracheal explants: effects of pollutants

    International Nuclear Information System (INIS)

    Last, J.A.; Kaizu, T.

    1980-01-01

    Tracheal slices incubated with radioactive precursors in tissue culture medium secrete labeled mucus glycoproteins into the culture medium. We have used an in vivtro approach, a combined method utilizing exposure to pneumotoxins in vivo coupled with quantitation of mucus secretion rates in vitro, to study the effects of inhaled pollutants on mucus biosynthesis by rat airways. In addition, we have purified the mucus glycoproteins secreted by rat tracheal explants in order to determine putative structural changes that might by the basis for the observed augmented secretion rates after exposure of rats to H2SO4 aerosols in combination with high ambient levels of ozone. After digestion with papain, mucus glycoproteins secreted by tracheal explants may be separated into five fractions by ion-exchange chromatography, with recovery in high yield, on columns of DEAE-cellulose. Each of these five fractions, one neutral and four acidic, migrates as a single unique spot upon cellulose acetate electrophoresis at pH values of 8.6 and 1.2. The neutral fraction, which is labeled with [3H] glucosamine, does not contain radioactivity when Na2 35SO4 is used as the precursor. Acidic fractions I to IV are all labeled with either 3H-glucosamine or Na2 35SO4 as precursor. Acidic fraction II contains sialic acid as the terminal sugar on its oligosaccharide side chains, based upon its chromatographic behavior on columns of wheat-germ agglutinin-Agarose. Treatment of this fraction with neuraminidase shifts its elution position in the gradient to a lower salt concentration, coincident with acidic fraction I. After removal of terminal sialic acid residues with either neuraminidase or low pH treatment, the resultant terminal sugar on the oligosaccharide side chains is fucose. These results are identical with those observed with mucus glycoproteins secreted by cultured human tracheal explants and purified by these same techniques

  17. Sonographic Findings of Primary Tracheal Lymphoma: Case Report

    International Nuclear Information System (INIS)

    Kim, Min Sung; Ahn, Kook Jin; Kim, Jee Young; Kim, Hyo Lim; Park, Jeong Mi

    2010-01-01

    Primary lymphoma of the trachea is extremely rare and clinical presentation is nonspecific. CT findings are focal tracheal narrowing caused by a solitary mass or polypoid thickening of the tracheobronchial wall caused by diffuse infiltration of the submucosa. However, US finding of primary lymphoma of the trachea has been not reported. We experienced a case of primary lymphoma of the trachea presenting as a homogenous hypoechoic mass, and discuss ultrasonographic and CT findings of the case

  18. Effects of α-particle radiation on rat tracheal epithelial cells

    International Nuclear Information System (INIS)

    Ford, J.R. Jr.

    1992-08-01

    By a combination of methods, which included flow cytometry and magnetic cell sorting, we have demonstrated that the cells of the rat tracheal epithelium which have the greatest proliferative capacity in culture and in vivo are the basal cells. Because of these findings it seems reasonable to suppose that the basal cells are the most likely target for the action of α-particle radiation in pseudostratified respiratory epithelium. This hypothesis is further supported by the finding that the basal cells are the cells which appear to respond to the tumor promoter 12-O-tetradecanoylphorbol-13-acetate. The effects of 210 Po α-particles on the survival and oncogenic transformation of rat tracheal epithelial cells in suspension were investigated. Since these effects were assayed in culture, the results pertain to the reaction of only the basal cells to irradiation. The results indicate that α-particles are extremely cytotoxic in that a track segment of 4 μm, on average, is sufficient to cause the reproductive death of basal cells. This finding is supported by similar results obtained with two cell lines, Mv1Lu and CHO-K1 BH 4 . Production of proliferating epithelial foci by α-particles was not distinguishable from control and sham treatments. These results are in direct conflict with many of the results that have been obtained with C3H 1OT1/2 cells in similar transformation assays. Some possible reasons for these disparities are discussed and supporting evidence is provided

  19. Regeneration of tracheal epithelium using mouse induced pluripotent stem cells.

    Science.gov (United States)

    Ikeda, Masakazu; Imaizumi, Mitsuyoshi; Yoshie, Susumu; Otsuki, Koshi; Miyake, Masao; Hazama, Akihiro; Wada, Ikuo; Omori, Koichi

    2016-01-01

    Conclusion The findings demonstrated the potential use of induced pluripotent stem cells for regeneration of tracheal epithelium. Objective Autologous tissue implantation techniques using skin or cartilage are often applied in cases of tracheal defects with laryngeal inflammatory lesions and malignant tumor invasion. However, these techniques are invasive with an unstable clinical outcome. The purpose of this study was to investigate regeneration in a tracheal defect site of nude rats after implantation of ciliated epithelium that was differentiated from induced pluripotent stem cells. Method Embryoid bodies were formed from mouse induced pluripotent stem cells. They were cultured with growth factors for 5 days, and then cultured at the air-liquid interface. The degree of differentiation achieved prior to implantation was determined by histological findings and the results of real-time polymerase chain reaction. Embryoid bodies including ciliated epithelium were embedded into collagen gel that served as an artificial scaffold, and then implanted into nude rats, creating an 'air-liquid interface model'. Histological evaluation was performed 7 days after implantation. Results The ciliated epithelial structure survived on the lumen side of regenerated tissue. It was demonstrated histologically that the structure was composed of ciliated epithelial cells.

  20. Myosin light chain kinase phosphorylation in tracheal smooth muscle

    International Nuclear Information System (INIS)

    Stull, J.T.; Hsu, L.C.; Tansey, M.G.; Kamm, K.E.

    1990-01-01

    Purified myosin light chain kinase from smooth muscle is phosphorylated by cyclic AMP-dependent protein kinase, protein kinase C, and the multifunctional calmodulin-dependent protein kinase II. Because phosphorylation in a specific site (site A) by any one of these kinases desensitizes myosin light chain kinase to activation by Ca2+/calmodulin, kinase phosphorylation could play an important role in regulating smooth muscle contractility. This possibility was investigated in 32 P-labeled bovine tracheal smooth muscle. Treatment of tissues with carbachol, KCl, isoproterenol, or phorbol 12,13-dibutyrate increased the extent of kinase phosphorylation. Six primary phosphopeptides (A-F) of myosin light chain kinase were identified. Site A was phosphorylated to an appreciable extent only with carbachol or KCl, agents which contract tracheal smooth muscle. The extent of site A phosphorylation correlated to increases in the concentration of Ca2+/calmodulin required for activation. These results show that cyclic AMP-dependent protein kinase and protein kinase C do not affect smooth muscle contractility by phosphorylating site A in myosin light chain kinase. It is proposed that phosphorylation of myosin light chain kinase in site A in contracting tracheal smooth muscle may play a role in the reported desensitization of contractile elements to activation by Ca2+

  1. Efficacy of transoral intraluminal Wallstents for tracheal stenosis or tracheomalacia.

    Science.gov (United States)

    Casiano, R R; Numa, W A; Nurko, Y J

    2000-10-01

    The efficacy and safety of intraluminal Wallstent Endoprosthesis (Boston Scientific/ Medi-Tech, Quincy, MA) placement to restore airway patency in patients with tracheal stenosis or tracheomalacia are unknown. Retrospective review in setting of tertiary, referral, and academic center. A retrospective review of 13 consecutive patients over a 2-year period who underwent transoral resection of tracheal stenosis and immediate transoral Wallstent placement. One patient had tracheomalacia. All of the patients were considered at high risk for transcervical surgery or had failed prior traditional open procedures. The average patient age was 54.2 years, with nine male and four female patients. All had Cotton/Myer stenoses (grades II to IV) with moderate to severe degrees of inspiratory stridor. Four patients were tracheotomy dependent. The length of stenosis varied from 1 to 4 cm. One patient had a 10-cm segment of tracheomalacia. At the time of writing, none of the patients has had a problem with significant migration or extrusion and most of the patients have incorporated the stent well without any short-term obstructive granulation tissue. After a mean follow-up of 15 months (range, 4-24 mo). 10 of the 12 patients with stenosis (83%) have remained free of any inspiratory noise during breathing. The one patient with tracheomalacia also has remained free of symptoms. Transoral Wallstents appear to be safe and may be a reasonable alternative in the restoration of airway patency in select patients with tracheal stenosis or tracheomalacia.

  2. Multimodal non-surgical treatment of a feline tracheal adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Carolina Azevedo

    2017-02-01

    Full Text Available Case summary A 10-year-old, castrated male domestic shorthair cat presented with a 2–3 month history of weight loss, lethargy and coughing. Thoracic radiographs revealed a soft tissue opacity overlying the dorsal trachea from the first rib to second rib and the ventral aspect of the trachea extending from the second rib to approximately the fourth rib. CT confirmed a mass involving the dorsal, right lateral and ventral aspects of the trachea narrowing the lumen and extending from vertebra C7 through T4. Bronchoscopy revealed a partially circumferential irregular and multilobulated tracheal mass, which was biopsied. The histopathological diagnosis was tracheal adenocarcinoma. The cat was treated with a definitive course of external beam radiation therapy (RT; 3 Gy × 18, cytotoxic chemotherapy, a tyrosine kinase inhibitor and palliative RT. The cat remained asymptomatic for 2 months and the mass remained stable radiographically for 11 months after RT. Relevance and novel information With multimodal treatment the cat had a survival time of 755 days. Initial treatment included definitive RT, carboplatin and piroxicam, followed by toceranib phosphate and palliative RT when the mass recurred. This case report describes the first documented use of non-surgical treatment and long-term outcome of tracheal adenocarcinoma in a cat. This case report is an indication that prolonged survival can be achieved with multimodal therapy.

  3. Evaluation of App-Based Serious Gaming as a Training Method in Teaching Chest Tube Insertion to Medical Students: Randomized Controlled Trial.

    Science.gov (United States)

    Haubruck, Patrick; Nickel, Felix; Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C

    2018-05-21

    The insertion of a chest tube should be as quick and accurate as possible to maximize the benefit and minimize possible complications for the patient. Therefore, comprehensive training and assessment before an emergency situation are essential for proficiency in chest tube insertion. Serious games have become more prevalent in surgical training because they enable students to study and train a procedure independently, and errors made have no effect on patients. However, up-to-date evidence regarding the effect of serious games on performance in procedures in emergency medicine remains scarce. The aim of this study was to investigate the serious gaming approach in teaching medical students an emergency procedure (chest tube insertion) using the app Touch Surgery and a modified objective structural assessment of technical skills (OSATS). In a prospective, rater-blinded, randomized controlled trial, medical students were randomized into two groups: intervention group or control group. Touch Surgery has been established as an innovative and cost-free app for mobile devices. The fully automatic software enables users to train medical procedures and afterwards self-assess their training effort. The module chest tube insertion teaches each key step in the insertion of a chest tube and enables users the meticulous application of a chest tube. In contrast, the module "Thoracocentesis" discusses a basic thoracocentesis. All students attended a lecture regarding chest tube insertion (regular curriculum) and afterwards received a Touch Surgery training lesson: intervention group used the module chest tube insertion and the control group used Thoracocentesis as control training. Participants' performance in chest tube insertion on a porcine model was rated on-site via blinded face-to-face rating and via video recordings using a modified OSATS tool. Afterwards, every participant received an individual questionnaire for self-evaluation. Here, trainees gave information about their

  4. trans-Caryophyllene, a Natural Sesquiterpene, Causes Tracheal Smooth Muscle Relaxation through Blockade of Voltage-Dependent Ca2+ Channels

    Directory of Open Access Journals (Sweden)

    Jader Santos Cruz

    2012-10-01

    Full Text Available trans-Caryophyllene is a major component in the essential oils of various species of medicinal plants used in popular medicine in Brazil. It belongs to the chemical class of the sesquiterpenes and has been the subject of a number of studies. Here, we evaluated the effects of this compound in airway smooth muscle. The biological activities of trans-caryophyllene were examined in isolated bath organs to investigate the effect in basal tonus. Electromechanical and pharmacomechanical couplings were evaluated through the responses to K+ depolarization and exposure to acetylcholine (ACh, respectively. Isolated cells of rat tracheal smooth muscle were used to investigate trans-caryophyllene effects on voltage-dependent Ca2+ channels by using the whole-cell voltage-clamp configuration of the patch-clamp technique. trans-Caryophyllene showed more efficiency in the blockade of electromechanical excitation-contraction coupling while it has only minor inhibitory effect on pharmacomechanical coupling. Epithelium removal does not modify tracheal smooth muscle response elicited by trans-caryophyllene in the pharmacomechanical coupling. Under Ca2+-free conditions, pre-exposure to trans-caryophyllene did not reduce the contraction induced by ACh in isolated rat tracheal smooth muscle, regardless of the presence of intact epithelium. In the whole-cell configuration, trans-caryophyllene (3 mM, inhibited the inward Ba2+ current (IBa to approximately 50% of control levels. Altogether, our results demonstrate that trans-caryophyllene has anti-spasmodic activity on rat tracheal smooth muscle which could be explained, at least in part, by the voltage-dependent Ca2+ channels blockade.

  5. Effect of just-in-time simulation training on tracheal intubation procedure safety in the pediatric intensive care unit.

    Science.gov (United States)

    Nishisaki, Akira; Donoghue, Aaron J; Colborn, Shawn; Watson, Christine; Meyer, Andrew; Brown, Calvin A; Helfaer, Mark A; Walls, Ron M; Nadkarni, Vinay M

    2010-07-01

    Tracheal intubation-associated events (TIAEs) are common (20%) and life threatening (4%) in pediatric intensive care units. Physician trainees are required to learn tracheal intubation during intensive care unit rotations. The authors hypothesized that "just-in-time" simulation-based intubation refresher training would improve resident participation, success, and decrease TIAEs. For 14 months, one of two on-call residents, nurses, and respiratory therapists received 20-min multidisciplinary simulation-based tracheal intubation training and 10-min resident skill refresher training at the beginning of their on-call period in addition to routine residency education. The rate of first attempt and overall success between refresher-trained and concurrent non-refresher-trained residents (controls) during the intervention phase was compared. The incidence of TIAEs between preintervention and intervention phase was also compared. Four hundred one consecutive primary orotracheal intubations were evaluated: 220 preintervention and 181 intervention. During intervention phase, neither first-attempt success nor overall success rate differed between refresher-trained residents versus concurrent non-refresher-trained residents: 20 of 40 (50%) versus 15 of 24 (62.5%), P = 0.44 and 23 of 40 (57.5%) versus 18 of 24 (75.0%), P = 0.19, respectively. The resident's first attempt and overall success rate did not differ between preintervention and intervention phases. The incidence of TIAE during preintervention and intervention phases was similar: 22.0% preintervention versus 19.9% intervention, P = 0.62, whereas resident participation increased from 20.9% preintervention to 35.4% intervention, P = 0.002. Resident participation continued to be associated with TIAE even after adjusting for the phase and difficult airway condition: odds ratio 2.22 (95% CI 1.28-3.87, P = 0.005). Brief just-in-time multidisciplinary simulation-based intubation refresher training did not improve the resident

  6. Tracheal Penetration and Tracheoesophageal Fistula Caused by an Esophageal Self-Expanding Metallic Stent

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2014-01-01

    Full Text Available Tracheal penetration of esophageal self-expanding metallic stents (SEMS with/without tracheoesophageal fistula (TEF formation is a rare occurrence. We report the case of a 66-year-old female patient with advanced esophageal squamous cell carcinoma who had undergone palliative esophageal stenting on three occasions for recurrent esophageal stent obstruction. On evaluation of symptoms of breathing difficulty and aspiration following third esophageal stent placement, tracheal erosion and TEF formation due to the tracheal penetration by esophageal stent were diagnosed. The patient was successfully managed by covered tracheal SEMS placement under flexible bronchoscopy.

  7. Two cases of severe tracheal stenosis due to advanced adenoid cystic carcinoma of the trachea

    Energy Technology Data Exchange (ETDEWEB)

    Yuasa, Hiroshi; Akaogi, Eiichi; Morita, Riichiro; Onizuka, Masataka; Mitsui, Kiyofumi [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Tsuji, Hirohiko

    1991-12-01

    Two cases of severe tracheal stenosis due to advanced nonresectable adenoid cystic carcinoma of the trachea were reported. Case 1 was a 38-year-old male who underwent emergency {sup 60}Co irradiation following endoscopic YAG laser irradiation. This approach was quite effective. Proton irradiation was effective against tumor recurrence. Case 2 was a 28-year-old female in whom emergency treatment for tracheal obstruction due to edema after laser therapy necessitated transient tracheal intubation. The tracheal stenosis due to recurrent tumor after {sup 60}Co irradiation was improved by insertion of an intraluminal permanent stent. (author).

  8. Fatal complication from a balloon-expandable tracheal stent in a child: a case report.

    Science.gov (United States)

    Stotz, William H; Berkowitz, Ivor D; Hoehner, Jeff C; Tunkel, David E

    2003-01-01

    The use of airway stents in the pediatric population is uncommon, reflected in the few patient series reported in the literature. We describe a fatal complication of tracheal stent placement in an 18-month-old child with spondylothoracic dysplasia. Case report. Intensive care unit of a tertiary academic pediatric center. An 18-month-old child with spondylothoracic dysplasia who underwent tracheal stent placement for tracheomalacia. Management of an acute upper-airway hemorrhage. The patient died, despite aggressive interventions. Use of tracheal stents in pediatric patients with tracheomalacia is not without risks; tracheal erosion with severe hemoptysis is an infrequent but devastating complication of this intervention.

  9. Static end-expiratory and dynamic forced expiratory tracheal collapse in COPD

    International Nuclear Information System (INIS)

    O'Donnell, C.R.; Bankier, A.A.; O'Donnell, D.H.; Loring, S.H.; Boiselle, P.M.

    2014-01-01

    Aim: To determine the range of tracheal collapse at end-expiration among chronic obstructive pulmonary disease (COPD) patients and to compare the extent of tracheal collapse between static end-expiratory and dynamic forced-expiratory multidetector-row computed tomography (MDCT). Materials and methods: After institutional review board approval and obtaining informed consent, 67 patients meeting the National Heart, Lung, and Blood Institute (NHLBI)/World Health Organization (WHO) Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria for COPD were sequentially imaged using a 64-detector-row CT machine at end-inspiration, during forced expiration, and at end-expiration. Standardized respiratory coaching and spirometric monitoring were employed. Mean percentage tracheal collapse at end-expiration and forced expiration were compared using correlation analysis, and the power of end-expiratory cross-sectional area to predict excessive forced-expiratory tracheal collapse was computed following construction of receiver operating characteristic (ROC) curves. Results: Mean percentage expiratory collapse among COPD patients was 17 ± 18% at end-expiration compared to 62 ± 16% during forced expiration. Over the observed range of end-expiratory tracheal collapse (approximately 10–50%), the positive predictive value of end-expiratory collapse to predict excessive (≥80%) forced expiratory tracheal collapse was <0.3. Conclusion: COPD patients demonstrate a wide range of end-expiratory tracheal collapse. The magnitude of static end-expiratory tracheal collapse does not predict excessive dynamic expiratory tracheal collapse

  10. Preparation and evaluation of a novel molecularly imprinted polymer coating for selective extraction of indomethacin from biological samples by electrochemically controlled in-tube solid phase microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Asiabi, Hamid [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Yamini, Yadollah, E-mail: yyamini@modares.ac.ir [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Seidi, Shahram; Ghahramanifard, Fazel [Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of)

    2016-03-24

    In the present work, an automated on-line electrochemically controlled in-tube solid-phase microextraction (EC-in-tube SPME) coupled with HPLC-UV was developed for the selective extraction and preconcentration of indomethacin as a model analyte in biological samples. Applying an electrical potential can improve the extraction efficiency and provide more convenient manipulation of different properties of the extraction system including selectivity, clean-up, rate, and efficiency. For more enhancement of the selectivity and applicability of this method, a novel molecularly imprinted polymer coated tube was prepared and applied for extraction of indomethacin. For this purpose, nanostructured copolymer coating consisting of polypyrrole doped with ethylene glycol dimethacrylate was prepared on the inner surface of a stainless-steel tube by electrochemical synthesis. The characteristics and application of the tubes were investigated. Electron microscopy provided a cross linked porous surface and the average thickness of the MIP coating was 45 μm. Compared with the non-imprinted polymer coated tubes, the special selectivity for indomethacin was discovered with the molecularly imprinted coated tube. Moreover, stable and reproducible responses were obtained without being considerably influenced by interferences commonly existing in biological samples. Under the optimal conditions, the limits of detection were in the range of 0.07–2.0 μg L{sup −1} in different matrices. This method showed good linearity for indomethacin in the range of 0.1–200 μg L{sup −1}, with coefficients of determination better than 0.996. The inter- and intra-assay precisions (RSD%, n = 3) were respectively in the range of 3.5–8.4% and 2.3–7.6% at three concentration levels of 7, 70 and 150 μg L{sup −1}. The results showed that the proposed method can be successfully applied for selective analysis of indomethacin in biological samples. - Graphical abstract: An automated on

  11. Tracheal stenosis: our experience at a tertiary care centre in India with special regard to cause and management.

    Science.gov (United States)

    Nair, Satish; Mohan, Sharad; Mandal, Ghanashyam; Nilakantan, Ajith

    2014-01-01

    Tracheal stenosis (TS), a challenging problem, is a known complication of prolonged intubation and tracheostomy. The management involves a multidisciplinary approach with multiple complex procedures. In this study we discuss our experience with severe TS with regards to patient characteristics, cause and management. A retrospective analysis of 20 patients of severe TS treated at a tertiary care centre was evaluated. Inclusion criteria were all patients with severe TS who required surgical intervention. Exclusion criteria were patients with associated laryngeal stenosis and TS due to cancer. Demographic data was recorded and findings relating to aetiology, characteristics of stenosis and the various aspects of therapeutic procedures performed are discussed with review of literature. Descriptive analysis of data were performed SPSS 18. Results of the 20 patients, 17 patients (85 %) developed TS post tracheostomy, or post intubation and subsequent tracheostomy. 13 Patients (65 %) had true stenosis of which 7 patients (35 %) had simple web or circumferential fibrosis and 6 patients (30 %) had complex stenosis. Seven patients (35 %) had granulations causing severe TS which were mostly suprastomal (5 patients), stomal (5 patients) and combined stomal and suprastomal (3 patients). The average length of stenosis was 3.57 cm (0.5-8 cm). Montgomery t tube insertion was a common procedure in 18 patients (90 %) pre or post intervention. Each patient underwent an average of 3.4 procedures during their course of treatment which included rigid bronchoscopy and mechanical debulking, Nd YAG laser, KTP laser, balloon dilatation and use of stents. Among the 7 patients with granulations 100 % successful decanulation was noted with endoscopic management whereas in 13 patients with true stenosis, 10 patients (76.9 %) required open surgical management (8 tracheal resection and anastomosis and 2 tracheoplasty) with 80 % successful decanulation, 2 patients (15.4 %) were treated

  12. Expander for Thin-Wall Tubing

    Science.gov (United States)

    Pessin, R.

    1983-01-01

    Tool locally expands small-diameter tubes. Tube expander locally expands and deforms tube: Compressive lateral stress induced in elastomeric sleeve by squeezing axially between two metal tool parts. Adaptable to situations in which tube must have small bulge for mechanical support or flow control.

  13. Hippocrates (ca 460-375 bc), Introducing Thoracotomy Combined With a Tracheal Intubation for the Parapneumonic Pleural Effusions and Empyema Thoracis.

    Science.gov (United States)

    Tsoucalas, Gregory; Sgantzos, Markos

    2016-12-01

    Hippocrates was the first physician to describe in accuracy pleural effusion and pneumonia. To treat empyema thoracis he had introduced a combined method of tracheal intubation with a simultaneously thoracotomy. The surgical incision was used for the pus to be progressively drainaged. If the patient was too weak to eat, he had suggested for nutritional mixtures to be administered through an oral-gastric tube. Thus Hippocrates composed in his operating theatre, an icon similar to modern surgical operations. © The Author(s) 2016.

  14. Feeding Tubes

    Science.gov (United States)

    ... feeding therapies have been exhausted. Please review product brand and method of placement carefully with your physician ... Total Parenteral Nutrition. Resources: Oley Foundation Feeding Tube Awareness Foundation Children’s Medical Nutrition Alliance APFED’s Educational Webinar ...

  15. Immediate, short-, and long-term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome.

    Science.gov (United States)

    Raske, Matthew; Weisse, Chick; Berent, Allyson C; McDougall, Renee; Lamb, Kenneth

    2018-03-01

    Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Identify immediate post-stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate-, short-, and long-term periods, and evaluate inter-observer reliability of radiographic measurements. Fifty client-owned dogs. Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post-stent placement radiographic follow-up times. Radiographs were used to obtain pre-stent tracheal measurements and post-stent placement measurements. Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Ultimate mean follow-up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long-term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short-, or long-term periods. Good inter-observer agreement of radiographic measurements was found among observers of variable experience level. Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  16. Immediate, short‐, and long‐term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome

    Science.gov (United States)

    Raske, Matthew; Berent, Allyson C.; McDougall, Renee; Lamb, Kenneth

    2018-01-01

    Background Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Objectives Identify immediate post‐stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate‐, short‐, and long‐term periods, and evaluate inter‐observer reliability of radiographic measurements. Animals Fifty client‐owned dogs. Methods Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post‐stent placement radiographic follow‐up times. Radiographs were used to obtain pre‐stent tracheal measurements and post‐stent placement measurements. Results Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Ultimate mean follow‐up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long‐term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short‐, or long‐term periods. Good inter‐observer agreement of radiographic measurements was found among observers of variable experience level. Conclusions and Clinical Importance Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. PMID:29460368

  17. Fabrication of seamless calandria tubes

    International Nuclear Information System (INIS)

    Saibaba, N.; Phanibabu, C.; Bhaskara Rao, C.V.; Kalidas, R.; Ganguly, C.

    2002-01-01

    Full text: Calandria tube is a large diameter, thin walled zircaloy-4 tube and is an important structural component of PHWR type of reactors. These tubes are lifetime components and remain during the full life of the reactor. Calandria tubes are classified as extremely thin walled tubes with a diameter to wall thickness ratio of around 96. Such thin walled tubes are conventionally produced by seam welded route comprising of extrusion of slabs followed by a series of hot and rolling passes, shaping into O-shape and eventual welding. An alternative and superior method of fabricating the calandria tubes, the seamless route, has been developed, which involves hot extrusion of mother blanks followed by three successive cold pilger reductions. Eccentricity correction of the extruded blanks is carried out on a special purpose grinding equipment to bring the wall thickness variation within permissible limits. Predominant wall thickness reductions are given during cold pilgering to ensure high Q-factor values. The texture in the finished tubes could be closely, controlled with an average f r value of 0.65. Pilgering parameters and tube guiding system have been specially designed to facilities rolling of thin walled tubes. Seamless calandria tubes have distinct advantages over welded tubes. In addition to the absence of weld, they are dimensionally more stable, lighter in weight and possess uniform grains with superior grain size. The cycle time from billet to finished product is substantially reduced and the product is amenable to high level of quality assurance. The most significant feature of the seamless route is its material recovery over welded route. Residual stresses measured in the tubes indicate that these are negligible and uniform along the length of the tube. In view of their superior quality, the first charge of seamless calandria tubes will be rolled into the first 500 MWe Pressurised Heavy Water Reactor at Tarapur

  18. Fabrication of tubed functionally graded material by slurry dipping process. Thickness control of dip-coated layer

    International Nuclear Information System (INIS)

    Watanabe, Ryuzo

    1997-03-01

    In order to obtain long life fuel cladding tubes for the fast breeder reactor, the concept of functionally graded material was applied for the material combination of Molybdenum/stainless steel/Titanium, in which Titanium and Molybdenum were placed at the inner and outer sides, respectively. Slurry dipping method was employed because of its capability of shape forming and microstructural control. We have hitherto reported the design criteria for the graded layers, preparation of the slurry, and microstructural control of the dip-coated layers. In the present report, the thickness control of the dip-coated layer is described in detail. The thickness of the dip-coated layer depends primarily on the viscosity of the slurry. Nevertheless, for the stable dispersion of the powder in the slurry, which dominates the microstructural homogeneity, an optimum viscosity value is present for the individual slurries. With stable slurries of Ti, Mo, stainless steel powders and their mixtures, the thicknesses of dip-coated layers were controlled in dependence of their viscosities and yield values. For Ti and stainless steel powders and their mixture a PAANa was used as a dispersing agent. A NaHMP was found to be effective for the dispersion of Mo powder and Mo/stainless steel powder mixture. For all slurries tested in the present investigation PVA addition was helpful for the viscosity control. Dip-coating maps have been drawn for the stabilization of the slurries and for the formation of films with a sufficient strength for further manipulation for the slurries with low viscosity (∼10 mPa s). The final film thickness for the low-viscosity slurry with the optimum condition was about 200 μm. The slurries with high viscosities of several hundreds mPa s had a good stability and the yield value was easy to be controlled. The film thickness was able to be adjusted in the size range between several tens and several hundreds μm. The final thickness of the graded layer was determined

  19. Remifentanil vs. Lidocaine on Response to Tracheal Tube during Emergence of General Anesthesia

    Directory of Open Access Journals (Sweden)

    Kambiz Sadegi

    2014-08-01

    Conclusion: we specified Remifentanil reduces cough during the emergence from general anesthesia more effective than Lidocaine in patients undergoing general surgery. In addition, Remifentanil and i.v. lidocaine revealed comparable impact regarding VAS scoring, sedation level and pethidine consumption.

  20. Are new supraglottic airway devices, tracheal tubes and airway viewing devices cost-effective?

    Science.gov (United States)

    Slinn, Simon J; Froom, Stephen R; Stacey, Mark R W; Gildersleve, Christopher D

    2015-01-01

    Over the past two decades, a plethora of new airway devices has become available to the pediatric anesthetist. While all have the laudable intention of improving patient care and some have proven clinical benefits, these devices are often costly and at times claims of an advantage over current equipment and techniques are marginal. Supraglottic airway devices are used in the majority of pediatric anesthetics delivered in the U.K., and airway-viewing devices provide an alternative for routine intubation as well as an option in the management of the difficult airway. Yet hidden beneath the convenience of the former and the technology of the latter, the impact on basic airway skills with a facemask and the lack of opportunities to fine-tune the core skill of intubation represent an unrecognised and unquantifiable cost. A judgement on this value must be factored into the absolute purchase cost and any potential benefits to the quality of patient care, thus blurring any judgement on cost-effectiveness that we might have. An overall value on cost-effectiveness though not in strict monetary terms can then be ascribed. In this review, we evaluate the role of these devices in the care of the pediatric patient and attempt to balance the advantages they offer against the cost they incur, both financial and environmental, and in any quality improvement they might offer in clinical care. © 2014 John Wiley & Sons Ltd.

  1. On-line electrochemically controlled in-tube solid phase microextraction of inorganic selenium followed by hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Asiabi, Hamid [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Yamini, Yadollah, E-mail: yyamini@modares.ac.ir [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Seidi, Shahram [Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of); Shamsayei, Maryam; Safari, Meysam; Rezaei, Fatemeh [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of)

    2016-05-30

    In this work, for the first time, a rapid, simple and sensitive microextraction procedure is demonstrated for the matrix separation, preconcentration and determination of inorganic selenium species in water samples using an electrochemically controlled in-tube solid phase microextraction (EC-in-tube SPME) followed by hydride generation atomic absorption spectrometry (HG-AAS). In this approach, in which EC-in-tube SPME and HG-AAS system were combined, the total analysis time, was decreased and the accuracy, repeatability and sensitivity were increased. In addition, to increases extraction efficiency, a novel nanostructured composite coating consisting of polypyrrole (PPy) doped with ethyleneglycol dimethacrylate (EGDMA) was prepared on the inner surface of a stainless-steel tube by a facile electrodeposition method. To evaluate the offered setup and the new PPy-EGDMA coating, it was used to extract inorganic selenium species in water samples. Extraction of inorganic selenium species was carried out by applying a positive potential through the inner surface of coated in-tube under flow conditions. Under the optimized conditions, selenium was detected in amounts as small as 4.0 parts per trillion. The method showed good linearity in the range of 0.012–200 ng mL{sup −1}, with coefficients of determination better than 0.9996. The intra- and inter-assay precisions (RSD%, n = 5) were in the range of 2.0–2.5% and 2.7–3.2%, respectively. The validated method was successfully applied for the analysis of inorganic selenium species in some water samples and satisfactory results were obtained. - Graphical abstract: An electrochemically controlled in-tube solid phase microextraction followed by hydride generation atomic absorption spectrometry was developed for extraction and determination ultra-trace amounts of Se in aqueous solutions. - Highlights: • A nanostructured composite coating consisting of PPy doped with EGDMA was prepared. • The coating was

  2. Steam generator tube extraction

    International Nuclear Information System (INIS)

    Delorme, H.

    1985-05-01

    To enable tube examination on steam generators in service, Framatome has now developed a process for removing sections of steam generator tubes. Tube sections can be removed without being damaged for treating the tube section expanded in the tube sheet

  3. Fetoscopic tracheal occlusion for severe congenital diaphragmatic hernia: retrospective study

    Directory of Open Access Journals (Sweden)

    Angélica de Fátima de Assunção Braga

    Full Text Available Abstract Background and objectives: The temporary fetal tracheal occlusion performed by fetoscopy accelerates lung development and reduces neonatal mortality. The aim of this paper is to present an anesthetic experience in pregnant women, whose fetuses have diaphragmatic hernia, undergoing fetoscopic tracheal occlusion (FETO. Method: Retrospective, descriptive study, approved by the Institutional Ethics Committee. Data were obtained from medical and anesthetic records. Results: FETO was performed in 28 pregnant women. Demographic characteristics: age 29.8 ± 6.5; weight 68.64 ± 12.26; ASA I and II. Obstetric: IG 26.1 ± 1.10 weeks (in FETO; 32.86 ± 1.58 (reversal of occlusion; 34.96 ± 2.78 (delivery. Delivery: cesarean section, vaginal delivery. Fetal data: Weight (g in the occlusion and delivery times, respectively (1045.82 ± 222.2 and 2294 ± 553; RPC in FETO and reversal of occlusion: 0.7 ± 0.15 and 1.32 ± 0.34, respectively. Preoperative maternal anesthesia included ranitidine and metoclopramide, nifedipine (VO and indomethacin (rectal. Preanesthetic medication with midazolam IV. Anesthetic techniques: combination of 0.5% hyperbaric bupivacaine (5-10 mg and sufentanil; continuous epidural predominantly with 0.5% bupivacaine associated with sufentanil, fentanyl, or morphine; general. In 8 cases, there was need to complement via catheter, with 5 submitted to PC and 3 to BC. Thirteen patients required intraoperative sedation; ephedrine was used in 15 patients. Fetal anesthesia: fentanyl 10-20 mg.kg-1 and pancuronium 0.1-0.2 mg.kg-1 (IM. Neonatal survival rate was 60.7%. Conclusion: FETO is a minimally invasive technique for severe congenital diaphragmatic hernia repair. Combined blockade associated with sedation and fetal anesthesia proved safe and effective for tracheal occlusion.

  4. Tracheal ceramic rings for tracheomalacia: a review after 17 years.

    Science.gov (United States)

    Göbel, Gyula; Karaiskaki, Niki; Gerlinger, Imre; Mann, Wolf J

    2007-10-01

    Despite different support techniques, the surgical management of tracheomalacia is still a challenging problem. Satisfactory results after internal stenting are above 80%, whereas, when performing external stenting using biocompatible ceramic rings, results are reported at over 90%. The purpose of this study was to examine the efficiency of surgical treatment in patients with segmentary tracheomalacia using external ceramic ring grafts. In this retrospective study, we collected data from 12 patients who underwent surgery during the last 17 years for symptomatic segmentary tracheomalacia by use of biocompatible aluminum-oxide ceramic rings. All except one patient had undergone previous tracheostomy, six had a history of long-term intubation, two had previous trauma, and two patients had previous cancer treatment including radiotherapy. One of the patients still had an existing tracheostoma, which was closed when a ceramic ring was implanted. Tracheal wall collapse with pseudoglottis formation or flattened anterior-posterior tracheal diameter was documented with fiberoscopy at rest, and both pre- and postoperative airway resistance measurements were performed in all 12 patients using a spirometer. After malacic segments were found to be expandable using rigid tracheoscopy while the patient was under general anesthesia, preparation of the trachea was performed using a midline vertical incision in the neck. Subsequently, the malacic trachea was expanded by placing and suturing proper-sized ceramic ring(s) around it. In all patients, surgical expansion of the malacic segment using ceramic rings was successfully carried out without major complications while inspiratory stridor was resolved. Airway resistance decreased significantly from an average of 0.62 to 0.385 kPascal. Although the results of applying internal tracheal stents are encouraging, complications such as stent migration, granulation tissue and fistula formation, and mucociliary transport arrest are possible

  5. Complications of ventilation tube insertion in children with and without cleft palate: a nested case-control comparison.

    Science.gov (United States)

    Smillie, Ian; Robertson, Sophie; Yule, Anna; Wynne, David M; Russell, Craig J H

    2014-10-01

    Optimizing hearing in patients with cleft lip and/or palate (CLP) by early recognition and management of otitis media with effusion is essential for speech development. Some evidence has suggested higher complication rates from ventilation tube (VT) insertion in patients with CLP and has led to a trend not to treat these patients surgically. However, studies have failed to match comparison groups for age and sex. To compare complication rates from VT insertion in pediatric patients with and without CLP. The study used a nested case-control design to evaluate 60 pediatric patients with CLP who underwent VT insertion at a children's hospital. The control group of age- and sex-matched patients was selected from a database of 2943 VT insertions. All patients were administered general anesthesia and underwent VT insertion by a pediatric otorhinolaryngology (ENT) team. The primary outcomes were numbers of otorrhea complications. Secondarily, rates of attendance at an ENT clinic specifically for complications were evaluated. Finally, numbers of complications other than otorrhea were assessed but not statistically analyzed owing to the varied types and low numbers in each group. The control cohort had 151 documented cases of otorrhea compared with 121 in the CLP group (ratio 1.25:1); the difference between groups was not statistically significant (P = .52). There was no significant difference in mean ENT clinic visits per patient for complications between groups (0.80 in the CLP group, 0.78 for controls) (P = .66). Regarding complications other than otorrhea, the control group reported more than the CLP group (43 vs 25; ratio, 1.7:1). Complication rates of VT placement among patients with CLP were not higher than those among patients without CLP. Therefore, treatment with VT insertion should be administered to patients with CLP under the same guidelines as for those without CLP. Indeed, there could be an argument for a shift in practice toward more aggressive

  6. Tracheal obstructions in two horses and a donkey

    International Nuclear Information System (INIS)

    Mair, T.S.; Lane, J.G.

    1990-01-01

    The clinical signs associated with intramural tracheal obstructions in two horses and a donkey were respiratory distress and coughing, which were aggravated by exercise and excitement. The obstructions were at the level of the thoracic inlet and consisted either of flattening of the cartilage rings in the dorsoventral plane or of cartilage rings having a scroll-like conformation. They appeared to be developmental in origin and to have been present for a considerable time before the onset of clinical signs. Endoscopy and radiography were helpful in the diagnosis of the condition

  7. Repopulation of denuded tracheal grafts with alveolar type II cells

    International Nuclear Information System (INIS)

    Johnson, N.F.

    1988-01-01

    Repopulation of denuded heterotopic tracheal grafts with populations of specific epithelial cell types is one approach to study the differentiation potential of various cell types. This technique has been adopted to delineate the differentiation pathways of alveolar type II cells isolated from rat lungs. Under the conditions of this experiment, the reestablished epithelial lining was alveolar-like, however, ultrastructural analysis of the cells showed them to be like Clara cells. These preliminary results suggest that the secretary cells of the lung parenchyma and terminal airways may share a common ancestry. (author)

  8. Evaluation of Tracheal and Main Bronchial Diverticula Using Thin-Section MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Jou, Sung Shick; Kim, Young Tong; Bae, Won Kyung; Kim, Il Yung; Kim, Hyung Hwan; Han, Jong Kyu [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of)

    2010-02-15

    To evaluate the characteristics of tracheal and main bronchial diverticula in relation with emphysema. A total of 967 CT images were reconstructed with 1.25 mm axial images over 2 months. The incidence, size, number, and location of the tracheal and main bronchial diverticula were analyzed using 3D medical software (Seoul, Korea). The incidence of emphysema and the relationship between emphysema and the size of the diverticula were analyzed. In total, 50 patients (5.1%) showed tracheal diverticula in the right posterolateral wall. In addition, 51 patients (5.2%) showed 89 (9.4%) main bronchial diverticula in the inferior wall, while 68 (72%) showed diverticula in the left posterolateral wall. Tracheal diverticula (6.4 {+-} 5.0 mm, 1.0 {+-} 0.2) were larger and fewer than the main bronchial diverticula (2.1 {+-} 2.0 mm, 1.8 {+-} 1.6) (p<0.05). Moreover, tracheal diverticula (10.3 {+-} 7.4 mm) with emphysema in 13 patients (26%), were larger than those without emphysema (5.1 {+-} 3.0 mm) (p<0.05). On thin-section MDCT, the rates of incidence for tracheal and main bronchial diverticula are about 5%, respectively. Tracheal diverticula in the right posterolateral wall are smaller and fewer than the main bronchial diverticula, which are located primarily in the inferior wall of the left bronchus. Tracheal diverticula with emphysema are larger than those without emphysema.

  9. Tracheal involvement of bronchus-associated lymphoid tissue lymphoma: a case report

    International Nuclear Information System (INIS)

    Sohn, Kyung Sik; Jeon, Kyung Neough; Kang, Duk Sik

    2002-01-01

    Primary malignant tumors of the trachea are rare, the most prevalent histologies beeing squamous cell and adenoid cystic carcinoma. A review of the literature revealed only ten cases of primary tracheal or bronchial non-Hodgkin's lymphoma. We describe a case in which tracheal involvement of bronchus-associated lymphoid tissue lymphoma, a subtype of non-Hodgkin's lymphoma, occurred

  10. The preventive effects of natural adjuvants, G2 and G2F on tracheal responsiveness and serum IL-4 and IFN-γ (th1/th2 balance in sensitized guinea pigs

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Boskabady

    2014-07-01

    Full Text Available OBJECTIVE:The effects of natural adjuvants on lung inflammation and tracheal responsiveness were examined in sensitized guinea pigs.METHODS:The responses of guinea pig tracheal chains and the serum levels of interleukin-4 and interferon-gamma were examined in control pigs and three other groups of guinea pigs: the sensitized group and two other sensitized groups treated with either adjuvant G2 or adjuvant G2F (n = 7 for each group. Sensitization of the animals was achieved by injection and inhalation of ovalbumin.RESULTS:The results showed that sensitized animals had increased tracheal responsiveness and increased serum levels of interleukin-4 and interferon-gamma compared to controls (p<0.05 to p<0.001. Treatments with either G2 or G2F prevented the increase in tracheal responsiveness and serum interleukin-4 (p<0.01 to p<0.001. However, the serum levels of interferon-gamma and the interleukin-4-to-interferon-gamma ratio was increased in the treated groups (p<0.001 for all cases.CONCLUSIONS:These results indicate important preventive effects of two natural adjuvants, particularly G2, on the changes in tracheal responsiveness, serum cytokines and the interleukin-4-to-interferon-gamma ratio (T helper 1/T helper 2 balance in sensitized guinea pigs.

  11. Influence of diffuse goiter on tracheal width

    International Nuclear Information System (INIS)

    Baik, Sung Mo; Shon, Hyung Sun; Kim, Choon Yul; Bahk, Yong Whee

    1980-01-01

    The radioisotopic scanning of the thyroid gland is well established method of demonstrating morphology of the thyroid gland and is used to measure the size, area and weight of thyroid gland. The purpose of this investigation is to observe the various effects of goiter to the regional trachea. Both radioisotopic scanning and roentgenogram were taken at the same time to evaluate size, area and weight of the thyroid glands, as well as to measure the width of soft tissue structure of the neck and the regional trachea in normal and goitrous patients. The clinical materials consisted of normal thyroid group for control (46 cases), diffuse simple goiter group (76 cases) and Graves' disease group (59 cases). The results were as follows; 1. The goiter causes some narrowing of the regional trachea to various degree which is not necessarily reflective of the size of goiter. 2. The goiter may increase the width of retrotracheal soft tissue space. 3. The lateral roentgenogram of the neck appear very useful in estimating the thyroid gland three dimensionally and the effect of goiter to the regional trachea

  12. Bronchial lumen is the safer route for an airway exchange catheter in double-lumen tube replacement: preventable complication in airway management for thoracic surgery.

    Science.gov (United States)

    Wu, Hsiang-Ling; Tai, Ying-Hsuan; Wei, Ling-Fang; Cheng, Hung-Wei; Ho, Chiu-Ming

    2017-10-01

    There is no current consensus on which lumen an airway exchange catheter (AEC) should be passed through in double-lumen endotracheal tube (DLT) to exchange for a single-lumen endotracheal tube (SLT) after thoracic surgery. We report an unusual case to provide possible solution on this issue. A 71-year-old man with lung adenocarcinoma had an event of a broken exchange catheter used during a DLT replacement with a SLT, after a video-assisted thoracic surgery. The exchange catheter was impinged at the distal tracheal lumen and snapped during manipulation. All three segments of the catheter were retrieved without further airway compromises. Placement of airway tube exchanger into the tracheal lumen of double-lumen tube is a potential contributing factor of the unusual complication. We suggest an exchange catheter be inserted into the bronchial lumen in optimal depth with the adjunct of video laryngoscope, as the safe method for double-lumen tube exchange.

  13. Use of the covered Y-shaped metallic stent in the treatment of airway stenoses involving the lower trachea and the tracheal carina: preliminary clinical study

    International Nuclear Information System (INIS)

    Yang Ruimin; Li Fenbao; Zhang Mingqiu; Wu Gang; Han Xinwei

    2007-01-01

    Objective: To describe a new kind of Y-shaped metallic stent delivery system and evaluate its feasibility and preliminary effect for managing multiple airway stenoses involving the lower trachea and the tracheal carina. Methods: The Y-shaped metallic stent delivery system consisted of three-tier structure. The inner-tier was composed of four parallel guiding tubes, which was used for two guidewires and two threads passing through, the middle-tier was delivery catheter, which contained the four guiding tubes, and the outer-tier was introducer sheath. Under the fluoroscopic guidance, 15 patients with multiple stenoses involving the lower trachea and the tracheal carina were treated with the new covered self-expandable Y-shaped metallic stents. Results: Stent placement in the tracheo-bronchial tree was technically successful in all patients with obliteration of the dyspnea immediately after stent placement, and SaO2 was increased form preoperative 75%-89% to postoperative 96%-99%. During follow-up a period of 3-58 weeks (M 22 weeks), all stenosis were resolved without stent-related complications, and the general physical of all 15 patents was improved with no occurrence of obviously dyspnea and bleeding. Karnofsky performance status (KPS) was improved from preoperative 26%-45% to postoperative 72%-95%. Five patients died of the following causes unrelated to stent insertion: multiple organ failure (n=3), cachexia (n=1) and pulmonary infection caused by gastrobronehial fistula (n=1), and the remaining 10 patients were alive with no evidence of dyspnea at the time of this report. Conclusion: Deployment of the covered Y-shaped metallic stent with the use of Y metallic stent delivery system in the management of airway stenoses involving the lower trachea and the tracheal carina was a simple and safe procedure and with a good short-term clinical efficacy. (authors)

  14. Use of the covered Y-shaped metallic stent in the treatment of airway stenoses involving the lower trachea and the tracheal carina: preliminary clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Ruimin, Yang; Fenbao, Li; Mingqiu, Zhang [Department of Intervention, First Affiliated Hospital, Xinxiang Medical Univ., Xinxiang (China); Gang, Wu; Xinwei, Han

    2007-09-15

    Objective: To describe a new kind of Y-shaped metallic stent delivery system and evaluate its feasibility and preliminary effect for managing multiple airway stenoses involving the lower trachea and the tracheal carina. Methods: The Y-shaped metallic stent delivery system consisted of three-tier structure. The inner-tier was composed of four parallel guiding tubes, which was used for two guidewires and two threads passing through, the middle-tier was delivery catheter, which contained the four guiding tubes, and the outer-tier was introducer sheath. Under the fluoroscopic guidance, 15 patients with multiple stenoses involving the lower trachea and the tracheal carina were treated with the new covered self-expandable Y-shaped metallic stents. Results: Stent placement in the tracheo-bronchial tree was technically successful in all patients with obliteration of the dyspnea immediately after stent placement, and SaO2 was increased form preoperative 75%-89% to postoperative 96%-99%. During follow-up a period of 3-58 weeks (M 22 weeks), all stenosis were resolved without stent-related complications, and the general physical of all 15 patents was improved with no occurrence of obviously dyspnea and bleeding. Karnofsky performance status (KPS) was improved from preoperative 26%-45% to postoperative 72%-95%. Five patients died of the following causes unrelated to stent insertion: multiple organ failure (n=3), cachexia (n=1) and pulmonary infection caused by gastrobronehial fistula (n=1), and the remaining 10 patients were alive with no evidence of dyspnea at the time of this report. Conclusion: Deployment of the covered Y-shaped metallic stent with the use of Y metallic stent delivery system in the management of airway stenoses involving the lower trachea and the tracheal carina was a simple and safe procedure and with a good short-term clinical efficacy. (authors)

  15. Managing a chest tube and drainage system.

    Science.gov (United States)

    Durai, Rajaraman; Hoque, Happy; Davies, Tony W

    2010-02-01

    Intercostal drainage tubes (ie, chest tubes) are inserted to drain the pleural cavity of air, blood, pus, or lymph. The water-seal container connected to the chest tube allows one-way movement of air and liquid from the pleural cavity. The container should not be changed unless it is full, and the chest tube should not be clamped unnecessarily. After a chest tube is inserted, a nurse trained in chest-tube management is responsible for managing the chest tube and drainage system. This entails monitoring the chest-tube position, controlling fluid evacuation, identifying when to change or empty the containers, and caring for the tube and drainage system during patient transport. This article provides an overview of indications, insertion techniques, and management of chest tubes. Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  16. Effects of hydration and physical therapy on tracheal transport velocity

    International Nuclear Information System (INIS)

    Chopra, S.K.; Taplin, G.V.; Simmons, D.H.; Coulson, A.; Elam, D.

    1976-01-01

    A new tracer method for quantitative measurements of tracheal transport velocity (TTV) in mm/min in dogs has been described recently. Using the same technique, the effects of dehydration, hydration, postural drainage and physical therapy on TTV were studied. There was a significant (p < 0.05) reduction in TTV following dehydration and these values reverted to normal with hydration in all ten dogs. Tracheal transport velocity increased on the average of 39.7 percent with a mean change of 7.7 mm/min (p < 0.01) following postural drainage in seven dogs. On the other hand, TTV increased on the average of 51 percent with a mean change of 8.2 mm/min (p <0.01) following chest percussion in six dogs. Postural drainage and chest percussion each increased TTV significantly beyond the base-line values. However, hydration only restored TTV to base-line values when applied to dogs in the hydropenic state. These therapeutic measures have been used empirically in the past. The present study gives objective evidence of their beneficial effects in dogs and suggests that such treatments may have a definite scientific basis for clinical application in chronic obstructive airways disease

  17. A case of tracheal leiomyoma misdiagnosed as asthma.

    Science.gov (United States)

    Öztürk, Ayperi; Aktaş, Zafer; Yılmaz, Aydın; Yeşildağlı, Havva; Memiş, Leyla

    2016-12-01

    Primary benign tumors of trachea are rare. Of them, tracheal leiomyoma, constitutes only 1% of all benign lower respiratory tract tumors. Here, we present a case of tracheal leiomyoma who has been receiving high doses of inhaled corticosteroids and bronchodilators for a year with a misdiagnosis of asthma. As the symptoms did not resolve with an overtreatment, she has been undergone radiologic study to find a possible alternative diagnosis. The chest roentgenogram revealed an opacity in the upper mediastinum. In computed tomography, a lesion has been detected in proximal trachea, arising from the posterior wall and protruding through the lumen and almost obliterating the air column. Rigid bronchoscopy has been performed under general anesthesia due to a high risk of bleeding and the endobronchial lesion, freely moving with respiration, has been removed and cryotherapy was applied to the base of the lesion. Receiving the histopathological diagnosis of leiomyoma, the patient is now on 12th month of the follow-up without any recurrence.

  18. Ear Tubes

    Science.gov (United States)

    ... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...

  19. Management of embedded metallic stents used in the treatment of grades III and IV subglottic, and upper tracheal stenosis in adults.

    Science.gov (United States)

    Sendi, Khalil; Al-Khatib, Talal; Ahmed, Duha G; Tonkul, Al-Baraa

    2014-11-01

    The aim of this study was to evaluate the post-operative complications of using balloon-expandable metallic stents in treatment of benign, major subglottic and tracheal stenosis in adult patients whom conventional therapy has failed and to demonstrate how to deal with these complications in the long run. A retrospective review of five cases; adlut patiets with benign, major subglottic and upper tracheal stenosis whom were treated with balloon expandable metallic stents at King Abdulaziz University Hospital, in the years between 2008 and 2013. Granulation tissue formed in five of the four cases and restenosis occurred. Other complications encountered were stent infection and dislodgment. The complications were managed by removing the stents surgically via a laryngofissure incision and required the placement of a Montgomery T-tube. Managing the restenosis due to granulation tissue formation around the metallic stents is best achieved by removing the embedded metallic stents surgically via open technique and then by placement of a Montgomery T-tube as a bridging option to successful decannulation. Open surgical procedures remain the mainstay treatment for advanced airway stenosis.

  20. Association of tracheal mucus or blood and airway neutrophilia with racing performance in Thoroughbred horses in an Australian racing yard.

    Science.gov (United States)

    Salz, R O; Ahern, B J; Boston, R; Begg, L M

    2016-04-01

    To determine the variation of tracheal mucus scores, tracheal blood scores and transendoscopic tracheal wash (TW) cytology in a population of Thoroughbred (TB) racehorses and assess their association with racing performance. A total of 220 endoscopic examinations were performed and TWs obtained from 155 TB racehorses. Samples were collected 60-120 min following gallop work. Tracheal mucus score, tracheal blood score and TW cytology were analysed and their association with racing performance assessed. Of the total examinations and samples, 194 from 135 horses fitted the criteria for inclusion. The overall prevalence of visible tracheal mucus was 2.5% (5/194) and of increased tracheal mucus was 0%. The prevalence of visible tracheal blood was 8.8% (17/194) and of increased tracheal blood was 4.6% (9/194). A total of 36% (70/194) of TWs contained elevated percentages of neutrophils and of these, 96% (67/70) occurred in the absence of any visible tracheal mucus. There was no significant association between tracheal mucus score or TW cytology and subsequent racing performance. There was a statistically significant association (P = 0.004) between increased tracheal blood scores and poor racing performance. Visible tracheal blood seen after strenuous exercise in clinically normal TB racehorses was a risk factor for poor racing performance, but the presence of airway neutrophilia was not. No horses in this study were found to have increased tracheal mucus, so the association of increased tracheal mucus with racing performance could not be assessed. © 2016 Australian Veterinary Association.

  1. Remotely controlled device for tightening, the nuts on locating pins for guide tubes in pressurized water reactors

    International Nuclear Information System (INIS)

    Styskal, P.

    1991-01-01

    The device has a support having a horizontal guide radial to the guide tube with a trolley moving on the guide and mounted on it a tool carrier. The tightening tool it self consists of a motor and an assembly of reducing gears mounted on the tool carrier. The final gear wheel in the assembly turns about a vertical axis and has a ferrule on its face for tightening the nut of the guide tube locating pin. The force of reaction on the tool carrier may be measured thus allowing the torque applied by the tool to be regulated [fr

  2. In service inspection for steam generator tubes

    International Nuclear Information System (INIS)

    Comby, R.; Eyrolles, Ph.

    1988-01-01

    In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations [fr

  3. Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (''ECG pulsing''): phantom measurements

    International Nuclear Information System (INIS)

    Poll, L.W.; Cohnen, M.; Brachten, S.; Moedder, U.; Ewen, K.

    2002-01-01

    To evaluate the effect of ECG-controlled tube current modulation on radiation exposure in retrospectively-ECG-gated multislice CT (MSCT) of the heart. Material and methods: Three different cardiac MSCT protocols with different slice collimation (4 x 1, and 4 x 2.5 mm), and a pitch-factor of 1.5 and 1.8 were investigated at a multi-slice CT scanner Somatom Volume Zoom, Siemens. An anthropomorphic Alderson-Rando phantom was equipped with LiF-Thermoluminescence dosimeters at several organ sites, and effective doses were calculated using ICRP-weighting factors. Scan protocols were performed with ECG-controlled tube current modulation ('ECG pulsing') at two different heart rates (60 and 80 bpm). These data were compared to previous data from MSCT of the heart without use of 'ECG pulsing'. Results: Radiation exposure with (60 bpm) and without tube current modulation using a 2.5 mm collimation was 1.8 mSv and 2.9 mSv for females, and 1.5 mSv and 2.4 mSv for males, respectively. For protocols using a 1 mm collimation with a pitch-factor of 1.5 (1.8), radiation exposure with and without tube current modulation was 5.6 (6.3) mSv and 9.5 (11.2) mSv for females, and 4.6 (5.2) mSv and 7.7 (9.2) mSv for males, respectively. At higher heart rates (80 bpm) radiation exposure is increased from 1.5-1.8 mSv to 1.8-2.1 mSv, using the 2.5 mm collimation, and from 4.6-5.6 mSv to 5.9-7.2 mSv, for protocols using 1 mm collimation. Conclusions: The ECG-controlled tube current modulation allows a dose reduction of 37% to 44% when retrospectively ECG-gated MSCT of the heart is performed. The tube current - as a function over time - and therefore the radiation exposure is dependent on the heart rate. (orig.) [de

  4. Tracheal relaxation of five medicinal plants used in Mexico for the treatment of several diseases.

    Science.gov (United States)

    Sánchez-Recillas, Amanda; Mantecón-Reyes, Paul; Castillo-España, Patricia; Villalobos-Molina, Rafael; Ibarra-Barajas, Maximiliano; Estrada-Soto, Samuel

    2014-03-01

    To assess the relaxant effect of several organic extracts obtained from Agastache mexicana (A. mexicana), Cochlospermum vitifolium (C. vitifolium), Cordia morelosana (C. morelosana), Lepechinia caulescens (L. caulescens) and Talauma mexicana (T. mexicana) used in Mexican traditional medicine for the treatment of several diseases. Extracts were obtained by maceration at room temperature using hexane, dichloromethane and methanol for each plant material. The organic extracts were evaluated ex vivo to determine their relaxant activity on the contractions induced by carbachol (cholinergic receptor agonist, 1 μ mol/L) in isolated rat tracheal rings. A total of 15 extracts were evaluated (three for each species). All test samples showed significant relaxant effect, in a concentration-dependent manner, on the contractions induced by 1 μ mol/L carbachol, with exception of extracts from C. morelosana. Active extracts were less potent than theophylline [phosphodiesterase inhibitor, EC50: (28.79±0.82) μg/mL] that was used as positive control. Concentration-response curves revealed that the extracts with more significant effects were dichloromethanic extracts of T. mexicana [Emax: (103.03±3.32)% and EC50: (159.39±3.72) μg/mL) and C. vitifolium [Emax: (106.58±2.42)% and EC50: (219.54±7.61) μg/mL]. Finally, hexanic and dichloromethanic extracts from A. mexicana were fully effective but less potent than T. mexicana and C. vitifolium. Less polar extracts obtained from A. mexicana, T. mexicana and C. vitifolium exhibited greater relaxant effect on tracheal rat rings, which allows us to suggest them as sources for the isolation of bioactive molecules with potential therapeutic value in the treatment of asthma. Copyright © 2014 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  5. Improved guide tube bulge tool

    International Nuclear Information System (INIS)

    Vaill, R.E.; Phillips, W.D.

    1979-01-01

    A guide tube bulge tool for securing control rod guide tubes to a fuel assembly grid, includes a cylinder having several flexible tines each of which is equipped with a semispherical radially outwardly extending projection. A tapered ram fits into the cylinder so as to force the tines outwardly when the ram is pulled into the cylinder while supporting the other tines. (UK)

  6. Epigenetic profiles in children with a neural tube defect; a case-control study in two populations

    NARCIS (Netherlands)

    L. Stolk (Lisette); M.I. Both (Marieke); N.H. van Mill (Nina); M.M.P.J. Verbiest (Michael); P.H.C. Eilers (Paul); H. Zhu (Huiping); L. Suarez (Lucina); A.G. Uitterlinden (André); R.P.M. Steegers-Theunissen (Régine)

    2013-01-01

    textabstractFolate deficiency is implicated in the causation of neural tube defects (NTDs). The preventive effect of periconceptional folic acid supplement use is partially explained by the treatment of a deranged folate-dependent one carbon metabolism, which provides methyl groups for

  7. Instrumentation and Control Systems for Sodium thermal hydraulic Experiment Loop for Finned-tube sodium-to-Air heat exchanger (SELFA)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byeong Yeon; Kim, Hyung Mo; Cho, Youn Gil; Kim, Jong Man; Ko, Yung Joo; Kang, Byeong Su; Jung, Min Hwan; Jeong, Ji Young [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    A forced-draft sodium-to-air heat exchanger (FHX) is a part of decay heat removal system (DHRS) in Prototype Gen-IV Sodium-cooled fast reactor (PGSFR), which is being developed at Korea Atomic Energy Research Institute (KAERI). Sodium thermal hydraulic Experiment Loop for Finned-tube sodium-to-Air heat exchanger (SELFA) is a test facility for verification and validation of the design code for a forced-draft sodium-to-air heat exchanger (FHX). In this paper, we have provided design and fabrication features for the instrumentation and control systems of SELFA. In general, the instrumentation systems and control systems are coupled for measurement and control of process variables. Instrumentation systems have been designed for investigating thermal-hydraulic characteristics of FHX and control systems have been designed to control the main components (e.g. electromagnetic pumps, heaters, valves etc.) required for test in SELFA. In this paper, we have provided configurations of instrumentation and control systems for Sodium thermal hydraulic Experiment Loop for Finned-tube sodium-to-Air heat exchanger (SELFA). The instrumentation and control systems of SELFA have been implemented based on the expected operation ranges and lesson learned from operational experience of 'Sodium integral effect test loop for safety simulation and assessment-1' (STELLA-1)

  8. Ciliated cells in vitamin A-deprived cultured hamster tracheal epithelium do divide

    International Nuclear Information System (INIS)

    Rutten, A.A.; Beems, R.B.; Wilmer, J.W.; Feron, V.J.

    1988-01-01

    The pseudostratified tracheal epithelium, composed of a heterogeneous phenotypically varying cell population, was studied with respect to the in vitro cell proliferative activity of differentiated epithelial cells. Ciliated tracheal epithelial cells so far have been considered to be terminally differentiated, nonproliferating cells. Tracheal organ cultures obtained from vitamin A-deprived Syrian Golden hamsters were cultured in a vitamin A-deficient, serum-free, hormone-supplemented medium. In vitamin A-deprived tracheal epithelium treated with physiologically active all-trans retinol and low cigarette-smoke condensate concentrations it is possible to stimulate the cell proliferation of both basal and columnar cells. Therefore, the probability of finding proliferating columnar cells was increased compared with the in vivo and the vitamin A-deprived situation in which cell proliferative activity is relatively low. In the presence of cigarette-smoke condensate in a noncytotoxic concentration, basal, small mucous granule, ciliated, and indifferent tracheal epithelial cells incorporated [methyl-3H]-thymidine into the DNA during the S phase. The finding that ciliated cells were labeled was supported by serial sections showing the same labeled ciliated cell in two section planes separated by 2 to 3 micron, without labeled epithelial cells next to the ciliated cell. Furthermore, a ciliated tracheal epithelial cell incorporating [methyl- 3 H]thymidine into DNA was also seen in tracheal cultures of vitamin A-deprived hamsters treated with all-trans retinol in a physiologic concentration

  9. Tracheal CT morphology: correlation with distribution and extent of thoracic adipose tissue

    Energy Technology Data Exchange (ETDEWEB)

    Ap Dafydd, Derfel [Imperial College Healthcare NHS Trust, Department of Radiology, Charing Cross Hospital, London (United Kingdom); Desai, Sujal R. [King' s College Hospital NHS Foundation Trust, King' s College London, King' s Health Partners, London (United Kingdom); Gordon, Fabiana; Copley, Susan J. [Imperial College, London (United Kingdom)

    2016-10-15

    To evaluate the relationship between adipose tissue measurements and anterior bowing of the posterior tracheal wall in a large nonselected group of patients undergoing CT pulmonary angiography (CTPA). Consecutive patients undergoing CTPA over a 4-month period were analyzed retrospectively. Using an adapted scoring system (posterior bowing, flattening, mild/moderate or severe anterior bowing of the posterior tracheal membrane), the axial morphology and cross-sectional area of the trachea at the narrowest point and 1 cm above the aortic arch were evaluated. Measurements of adipose tissue were taken (anterior mediastinal fat width, sagittal upper abdominal diameter and subcutaneous fat thickness at the level of the costophrenic angle). Relationships between tracheal morphology and measurements of adipose tissue were analyzed. 296 patients were included (120 males, 176 females, mean age 59 years, range 19-90). Severe anterior bowing of the posterior tracheal wall correlated with increasing sagittal upper abdominal diameter (p = 0.002). Mild/moderate and severe anterior bowing of the posterior tracheal wall correlated with increasing mediastinal fat width (p = 0.000 and p = 0.031, respectively). Tracheal cross-sectional area was inversely correlated with increasing subcutaneous fat thickness (p = 0.022). The findings demonstrate a statistically significant relationship between CT tracheal morphology and adipose tissue measurements in a large nonselected population. (orig.)

  10. Tracheal rupture caused by blunt chest trauma: radiological and clinical features

    Energy Technology Data Exchange (ETDEWEB)

    Kunisch-Hoppe, M.; Rauber, K.; Rau, W.S. [Dept. of Diagnostic Radiology, Justus Liebig Univ., Giessen (Germany); Hoppe, M. [Dept. of Diagnostic Radiology, University Hospital, Philipps University, Marburg (Germany); Popella, C. [Dept. of ENT, Justus Liebig University, Giessen (Germany)

    2000-03-01

    The aim of this study was to assess radiomorphologic and clinical features of tracheal rupture due to blunt chest trauma. From 1992 until 1998 the radiomorphologic and clinical key findings of all consecutive tracheal ruptures were retrospectively analyzed. The study included ten patients (7 men and 3 women; mean age 35 years); all had pneumothoraces which were persistent despite suction drainage. Seven patients developed a pneumomediastinum as well as a subcutaneous emphysema on conventional chest X-rays. In five patients, one major hint leading to the diagnosis was a cervical emphysema, discovered on the lateral cervical spine view. Contrast-media-enhanced thoracic CT was obtained in all ten cases and showed additional injuries (atelectasis n = 5; lung contusion n = 4; lung laceration n = 2; hematothorax n = 2 and hematomediastinum n = 4). The definite diagnosis of tracheal rupture was made by bronchoscopy, which was obtained in all patients. Tracheal rupture due to blunt chest trauma occurs rarely. Key findings were all provided by conventional chest X-ray. Tracheal rupture is suspected in front of a pneumothorax, a pneumomediastinum, or a subcutaneous emphysema on lateral cervical spine and chest films. Routine thoracic CT could also demonstrate these findings but could not confirm the definite diagnosis of an tracheal rupture except in one case; in the other 9 cases this was done by bronchoscopy. Thus, bronchoscopy should be mandatory in all suspicious cases of tracheal rupture and remains the gold standard. (orig.)

  11. Tracheal rupture caused by blunt chest trauma: radiological and clinical features

    International Nuclear Information System (INIS)

    Kunisch-Hoppe, M.; Rauber, K.; Rau, W.S.; Hoppe, M.; Popella, C.

    2000-01-01

    The aim of this study was to assess radiomorphologic and clinical features of tracheal rupture due to blunt chest trauma. From 1992 until 1998 the radiomorphologic and clinical key findings of all consecutive tracheal ruptures were retrospectively analyzed. The study included ten patients (7 men and 3 women; mean age 35 years); all had pneumothoraces which were persistent despite suction drainage. Seven patients developed a pneumomediastinum as well as a subcutaneous emphysema on conventional chest X-rays. In five patients, one major hint leading to the diagnosis was a cervical emphysema, discovered on the lateral cervical spine view. Contrast-media-enhanced thoracic CT was obtained in all ten cases and showed additional injuries (atelectasis n = 5; lung contusion n = 4; lung laceration n = 2; hematothorax n = 2 and hematomediastinum n = 4). The definite diagnosis of tracheal rupture was made by bronchoscopy, which was obtained in all patients. Tracheal rupture due to blunt chest trauma occurs rarely. Key findings were all provided by conventional chest X-ray. Tracheal rupture is suspected in front of a pneumothorax, a pneumomediastinum, or a subcutaneous emphysema on lateral cervical spine and chest films. Routine thoracic CT could also demonstrate these findings but could not confirm the definite diagnosis of an tracheal rupture except in one case; in the other 9 cases this was done by bronchoscopy. Thus, bronchoscopy should be mandatory in all suspicious cases of tracheal rupture and remains the gold standard. (orig.)

  12. Awake tracheal intubation using Pentax airway scope in 30 patients: A Case series

    Directory of Open Access Journals (Sweden)

    Payal Kajekar

    2014-01-01

    Full Text Available Background and Aims: Pentax airway scope (AWS has been successfully used for managing difficult intubations. In this case series, we aimed to evaluate the success rate and time taken to complete intubation, when AWS was used for awake tracheal intubation. Methods: We prospectively evaluated the use of AWS for awake tracheal intubation in 30 patients. Indication for awake intubation, intubation time, total time to complete tracheal intubation, laryngoscopic view (Cormack and Lehane grade, total dose of local anaesthetic used, anaesthetists rating and patient′s tolerance of the procedure were recorded. Results: The procedure was successful in 25 out of the 30 patients (83%. The mean (standard deviation intubation time and total time to complete the tracheal intubation was 5.4 (2.4 and 13.9 (3.7 min, respectively in successful cases. The laryngeal view was grade 1 in 24 and grade 2 in one of 25 successful intubations. In three out of the five patients where the AWS failed, awake tracheal intubation was successfully completed with the assistance of flexible fibre optic scope (FOS. Conclusion: Awake tracheal intubation using AWS was successful in 83% of patients. Success rate can be further improved using a combination of AWS and FOS. Anaesthesiologists who do not routinely use FOS may find AWS easier to use for awake tracheal intubation using an oral route.

  13. Electron tube

    Science.gov (United States)

    Suyama, Motohiro [Hamamatsu, JP; Fukasawa, Atsuhito [Hamamatsu, JP; Arisaka, Katsushi [Los Angeles, CA; Wang, Hanguo [North Hills, CA

    2011-12-20

    An electron tube of the present invention includes: a vacuum vessel including a face plate portion made of synthetic silica and having a surface on which a photoelectric surface is provided, a stem portion arranged facing the photoelectric surface and made of synthetic silica, and a side tube portion having one end connected to the face plate portion and the other end connected to the stem portion and made of synthetic silica; a projection portion arranged in the vacuum vessel, extending from the stem portion toward the photoelectric surface, and made of synthetic silica; and an electron detector arranged on the projection portion, for detecting electrons from the photoelectric surface, and made of silicon.

  14. Clinical application of self-expandable metallic stents in the treatment of malignant tracheal stenosis under general anesthesia

    International Nuclear Information System (INIS)

    Wang Weitao; Shi Haibin; Yang Zhengqiang; Liu Sheng; Zhou Chungao; Zhao Linbo; Xia Jinguo; Li Linsun

    2009-01-01

    Objective: To evaluate the safety and efficacy of self-expandable metallic stent placement for the treatment of malignant tracheal stenosis under general anesthesia and fluoroscopic guidance. Methods: Under general anesthesia the placement of self-expandable metallic stent was performed in 10 patients with malignant tracheal stenosis, the procedure was completed under fluoroscopic guidance in all patients. Results: Successful tracheal stenting was achieved in all 10 patients. In one patient, a Y-shaped stent was used as the tracheal carina was involved in the airway stenosis. The symptoms of dyspnea and asthma were markedly improved immediately after the implantation of stent in all patients. Conclusion: Tracheal implantation of self-expandable metallic stent under general anesthesia and fluoroscopic guidance is a safe and effective treatment for malignant tracheal stenosis, it can promptly relieve various symptoms caused by malignant tracheal stenosis and obviously improve patient's living quality, therefore,t his technique is of great value in clinical practice. (authors)

  15. SG tube identification

    International Nuclear Information System (INIS)

    Hoogstraten, P. van

    1994-01-01

    A ''Tracker'' system is described which is designed to identify any tube in a reactor steam generator quickly and safely. Occupational radiation doses to maintenance workers are reduced by using a Tracker and emergency down times are shortened. The system employs a television camera and light source in a stainless steel box with a large window. Both the camera and spotlight can be panned and tilted to reach any point on the tubesheet and are remotely controlled. An operator at a safe working distance can identify any tube visible on a real time video by comparison with the tubesheet pattern stored earlier in the computer memory. The identified tube can then be spotlighted and dealt with quickly by a maintenance worker inside the channel head. (UK)

  16. Use of the peritracheal fold in the dog tracheal transplantation model.

    Science.gov (United States)

    Gannon, P J; Costantino, P D; Lueg, E A; Chaplin, J M; Brandwein, M S; Passalaqua, P J; Fliegelman, L J; Laitman, J T; Marquez, S; Urken, M L

    1999-09-01

    To investigate the technical aspects of the canine model of human tracheal transplantation for potential application to reconstruction of extremely long tracheal defects (> 10 cm). In phase 1, long tracheal segments were skeletonized and pedicled with the thyroid glands, cranial thyroid arteries and veins, and internal jugular vein branches. The segments were elevated completely, attached to the vascular pedicle only, and replaced with primary tracheal anastomoses. In phase 2, long segments were elevated along with a diffuse soft tissue "blanket" that envelops the trachea and thyroid glands. Because this study was designed to primarily address, in situ, tracheal perfusion territories of a cranially located vascular pedicle, microvascular anastomoses were not conducted. Two small-bodied beagles (10-15 kg) and 5 large-bodied mixed-breed dogs (20-30 kg) were humanely killed 2 to 41 days after surgery, and anatomic and histological analyses were conducted. Unlike that of humans, the thyroid gland complex of dogs is not intimately associated with the trachea but is conjoined with a peritracheal soft tissue "fold." Within this fold, blood is transmitted to the trachea via a diffuse, segmental vascular plexus. In phase 1, pronounced tracheal necrosis occurred within 2 to 5 days. In phase 2, extremely long tracheal segments (10-12 cm), based only on a cranially located pedicle, were still viable at 2 to 6 weeks. Preservation of the "peritracheal fold" in the dog model of tracheal transplantation is critical to the onset and maintenance of vascular perfusion in a long tracheal segment. Furthermore, the use of large-bodied dogs is necessary to provide for a usable venous efflux component.

  17. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  18. Parameter optimization through performance analysis of model based control of a batch heat treatment furnace with low NO x radiant tube burner

    International Nuclear Information System (INIS)

    Tiwari, Manish Kumar; Mukhopadhyay, Achintya; Sanyal, Dipankar

    2005-01-01

    A model based control structure for heat treating a 0.5% C steel slab in a batch furnace with low NO x radiant tube burner is designed and tested for performance to yield optimal parameter values using the model developed in the companion paper. Combustion is considered in a highly preheated and product gas diluted mode. Controlled combustion with a proposed arrangement for preheating and diluting the air by recirculating the exhaust gas that can be retrofitted with an existing burner yields satisfactory performance and emission characteristics. Finally, the effect of variable property considerations are presented and critically analyzed

  19. Surgical treatment of benign tracheo-oesophageal fistulas with tracheal resection and oesophageal primary closure: is the muscle flap really necessary?

    Science.gov (United States)

    Camargo, José Jesus; Machuca, Tiago Noguchi; Camargo, Spencer Marcantônio; Lobato, Vivalde F; Medina, Carlos Remolina

    2010-03-01

    Nowadays, despite the advances of the low-pressure high-volume cuffs, post-intubation tracheo-oesophageal fistula (TEF) still poses a major challenge to thoracic surgeons. The original technique includes interposition of muscle flaps between suture lines to avoid recurrence. It is not clear if this manoeuvre is indispensable and, in fact, we and others have faced problems with it. Our aim is to present our experience with TEF management in a consecutive group with no muscle interposition. From June 1992 to November 2007, we evaluated 14 patients presenting with TEF, with a mean age of 44 years (from 18 to 79 years). Thirteen patients had a prolonged intubation history. The remaining case was a 40-year-old male with congenital TEF. Three patients had been previously submitted to failed repairs in other institutions. Ten patients had associated tracheal stenosis, which was subglottic in three of them. Regarding surgical technique, in all cases, we performed a single-staged procedure, which consisted of tracheal resection and anastomosis with double-layer oesophageal closure. In none of our cases was a muscle flap interposed between suture lines. All operations were performed through a cervical incision; however, in one case, an extension with partial sternotomy was required. There was no operative mortality. Thirteen patients were extubated in the first 24h after the procedure, while one patient required 48 h of mechanical ventilation. Four complications were recorded: one each of pneumonia and left vocal cord paralysis and two small tracheal dehiscences managed with a T-tube and a tracheostomy tube. After discharge, three patients returned to their native cities and were lost to follow-up. The remaining 11 patients have been followed up by a mean of 32 months (from three to 108 months), with 10 presenting excellent and one good anatomic and functional results. The single-staged repair with tracheal resection and anastomosis with oesophageal closure provides good

  20. Diagnosis of tracheomalacia using tracheal dynamic respiratory-scan

    International Nuclear Information System (INIS)

    Matsui, Teruo; Watabe, Hideki; Ikeda, Sadao

    1995-01-01

    We performed tracheal-dynamic respiratory scan (T-DRS) in 54 cases which were thought to be tracheomalacia clinically. T-DRS was performed by TOSHIBA TCT-900S at the level of the aortic arch under the condition of 120 kV (140 kV), 100 mA, 5 mm of slice width for 20 seconds when the patient was directed to breath rapidly or slowly. In 19 cases, which underwent both T-DRS and bronchoscopy, could evaluate the results. Only one case was overestimated by T-DRS than bronchoscopic findings, while 9 cases were underestimated and 9 cases were equal. Though T-DRS tended to underestimate the degree of the stenosis of tracheomalacia than bronchoscopic finding. T-DRS can do more objective evaluation than bronchoscopy non-invasively and thought to be useful for the evaluation of tracheomalalcia. (author)

  1. Effects of preoperative irradiation on primary tracheal anastomosis

    International Nuclear Information System (INIS)

    Tsubota, N.; Simpson, W.J.; Van Nostrand, A.W.P.; Pearson, F.G.

    1975-01-01

    Preoperative radiotherapy was used in the management of selected patients with cancer of the lung or trachea who might subsequently require segmental resection of bronchus or trachea and reconstruction by primary anastomosis. This study was designed to determine the effects of varying dosages of preoperative irradiation on anastomotic healing. Two rings were resected from the cervical trachea of 20 dogs following irradiation with varying doses of cesium. There were no important adverse effects on healing of the trachea or adjacent organs in dogs receiving up to 3,500 rads. All dogs receiving a higher dose than this developed some anastomotic stenosis, which was severe in 6 of 8 animals. Similar adverse effects were observed in 2 patients managed by preoperative radiotherapy (4,000 rads in three weeks) and tracheal resection with primary anastomosis

  2. Effects of preoperative irradiation on primary tracheal anastomosis

    Energy Technology Data Exchange (ETDEWEB)

    Tsubota, N.; Simpson, W.J.; Van Nostrand, A.W.P.; Pearson, F.G.

    1975-08-01

    Preoperative radiotherapy was used in the management of selected patients with cancer of the lung or trachea who might subsequently require segmental resection of bronchus or trachea and reconstruction by primary anastomosis. This study was designed to determine the effects of varying dosages of preoperative irradiation on anastomotic healing. Two rings were resected from the cervical trachea of 20 dogs following irradiation with varying doses of cesium. There were no important adverse effects on healing of the trachea or adjacent organs in dogs receiving up to 3,500 rads. All dogs receiving a higher dose than this developed some anastomotic stenosis, which was severe in 6 of 8 animals. Similar adverse effects were observed in 2 patients managed by preoperative radiotherapy (4,000 rads in three weeks) and tracheal resection with primary anastomosis.

  3. Manipulation of gene expression by infrared laser heat shock and its application to the study of tracheal development in Drosophila.

    Science.gov (United States)

    Miao, Guangxia; Hayashi, Shigeo

    2015-03-01

    Induction of gene expression in a specific cell and a defined time window is desirable to investigate gene function at the cellular level during morphogenesis. To achieve this, we attempted to introduce the infrared laser-evoked gene operator system (IR-LEGO, Kamei et al., 2009) in the Drosophila embryo. In this technique, infrared laser light illumination induces genes to be expressed under the control of heat shock promoters at the single cell level. We applied IR-LEGO to a transgenic fly stock, HS-eGFP, in which the enhanced green fluorescent protein (eGFP) gene is placed under the control of heat shock protein 70 promoter, and showed that eGFP expression can be induced in single cells within 1-2 hr after IR illumination. Furthermore, induction of HS-Branchless transgene encoding the Drosophila fibroblast growth factor (FGF) effectively altered the migration and branching patterns of the tracheal system. Our results indicated that IR-LEGO is a promising choice for the timely control of gene expression in a small group of cells in the Drosophila embryo. By using IR-LEGO, we further demonstrated that the tracheal terminal branching program is sensitive to localized expression of exogenous FGF. © 2014 Wiley Periodicals, Inc.

  4. Ethical issues in laryngology: tracheal stenting as palliative care.

    Science.gov (United States)

    Kazi, Aasif A; Flowers, W Jeffrey; Barrett, Jeanna M; O'Rourke, Ashli K; Postma, Gregory N; Weinberger, Paul M

    2014-07-01

    To improve understanding of aspects of end-of-life care that may not be intuitive to the otolaryngology community. A comprehensive review of the literature was performed by searching Medline, Embase, and Google Scholar databases. Primary manuscripts' bibliographies were reviewed to identify any nonindexed references. Prospective consultation by means of one-on-one interviews was sought from nonotolaryngology key stakeholders in the areas of hospice nursing care and patient advocacy in order to identify pertinent issues. We identified over 1,000 articles published from 1965 to 2013 on the topic of tracheal stents, as well as over 40,000 on hospice/end-of-life care. Three articles focusing specifically on palliative care and airway stenting were identified, of which three were case reports and none were definitive reviews. There are a number of significant issues and concepts unique to hospice care. These are likely unfamiliar to all except for head and neck oncology-specialized otolaryngologists. An example is that hospice care focuses on quality of life rather than prolongation of life (such as curative surgery). Patients with nonoperable tracheal obstruction from malignancy face an unpleasant demise from suffocation. For those patients, stenting can relieve suffering by restoring airway patency. Airway stenting can be a valid palliative care option, even for terminal patients receiving hospice care, when performed to relieve airway obstruction and improve quality of life. End-of-life ethics is an underdeveloped area of otolaryngology that should be explored. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Management of postintubation tracheal stenosis: appropriate indications make outcome differences.

    Science.gov (United States)

    Melkane, Antoine E; Matar, Nayla E; Haddad, Amine C; Nassar, Michel N; Almoutran, Homère G; Rohayem, Ziad; Daher, Mohammad; Chalouhy, Georges; Dabar, George

    2010-01-01

    Laryngotracheal stenosis is difficult to treat and its etiologies are multiple; nowadays, the most common ones are postintubation or posttracheostomy stenoses. To provide an algorithm for the management of postintubation laryngotracheal stenoses (PILTS) based on the experience of a tertiary care referral center. A retrospective study was conducted on all patients treated for PILTS over a 10-year period. Patients were divided into a surgically and an endoscopically treated group according to predefined criteria. The characteristics of the two groups were analyzed and the outcomes compared. Thirty-three consecutive patients were included in the study: 14 in the surgically treated group and 19 in the endoscopically treated group. Our candidates for airway surgery were healthy patients presenting with complex tracheal stenoses, subglottic involvement or associated tracheomalacia. The endoscopic candidates were chronically ill patients presenting with simple, strictly tracheal stenoses not exceeding 4 cm in length. Stents were placed if the stenosis was associated with tracheomalacia or exceeded 2 cm in total length. In the surgically treated group, 2/14 patients needed more than one procedure versus 8/19 patients in the endoscopically treated group. At the end of the intervention, 50% of the patients were decannulated in the surgically treated group versus 84.2% in the endoscopically treated group (p = 0.03). However, the decannulation rates at 6 months and the symptomatology at rest and on exertion on the last follow-up visit were comparable in the two groups. Our experience in the management of PILTS demonstrates that both surgery and endoscopy yield excellent functional outcomes if the treatment strategy is based on clear, predefined objective criteria. Copyright 2010 S. Karger AG, Basel.

  6. A comparison of simple continuous versus simple interrupted suture patterns for tracheal anastomosis after large-segment tracheal resection in dogs.

    Science.gov (United States)

    Fingland, R B; Layton, C I; Kennedy, G A; Galland, J C

    1995-01-01

    Two suture techniques for tracheal anastomosis after large-segment tracheal resection were compared. Eight cartilages were resected from the trachea of each of 12 dogs; anastomoses with 4-0 polydioxanone suture were created using a simple continuous suture technique in six dogs and a simple interrupted suture technique in six dogs. Surgical time was shorter but apposition of tracheal segments at the time of surgery was less precise with the simple continuous suture technique. The dogs were evaluated for 150 days after surgery. Clinical abnormalities after tracheal resection and anastomosis were not observed. Percent dorsoventral luminal stenosis was calculated by measuring the tracheal lumen diameter on lateral cervical radiographs. Percent luminal stenosis was calculated planimetrically using a computerized digitizing tablet. Anastomotic stenosis was mild in all dogs; however, the mean percent.luminal stenosis determined planimetrically was significantly greater for dogs that had the simple continuous suture technique. Planimetric measurements of cross-sectional area made before and after formalin fixation were not significantly different. Radiographic determination of percent dorsoventral luminal stenosis was a poor predictor of diminution of cross-sectional area determined planimetrically.

  7. Experimental investigation of vortex control with an axial jet in the draft tube of a model pump-turbine

    International Nuclear Information System (INIS)

    Kirschner, O; Schmidt, H; Ruprecht, A; Mader, R; Meusburger, P

    2010-01-01

    The operation of hydropower plants, especially of pump-storage plants, changes since the deregulation of the energy market. They are increasingly operating at off-design conditions in order to follow the demand in the electrical grid. Therefore the ability of hydropower plants handling the operation in a wide range of off-design conditions has become more important. In this context one problem is the vortex rope in the draft tube, especially for Francis turbines and pump-turbines running in part load. An experimental investigation in mitigation of the vortex rope phenomenon by injecting water axially in the centre of the draft tube on a pump-turbine model was carried out. Also the mitigation by additionally injected air in the centre of the draft tube was analysed. The results of the experimental investigation are focused on the reduction of the pressure fluctuations in the draft tube. In this paper two different part-load operating points were investigated. One of these operating points is a high part load operating point where a vortex rope exists. The other one is a low part load operating point, where the pressure fluctuation is not caused by a vortex rope. The results of the investigation show, that the injection of stabilizing water can mitigate the pressure fluctuation caused by a vortex rope. But the investigation of operating points where the pressure fluctuation is not caused by a vortex rope shows, that there is no significant reduction in the pressure fluctuation by this method. In these operating points the method of injecting additionally air reduces the pressure fluctuation better.

  8. Use of the iTClamp versus standard suturing techniques for securing chest tubes: A randomized controlled cadaver study

    Directory of Open Access Journals (Sweden)

    Jessica Mckee

    2018-03-01

    Full Text Available Objectives: Tube thoracostomy (TT is a common yet potentially life-saving trauma procedure. After successful placement however, securing a TT through suturing is a skillset that requires practice, risking that the TT may become dislodged during prehospital transport. The purpose of this study was to examine if the iTClamp was a simpler technique with equivalent effectiveness for securing TTs. Materials and methods: In a cadaver model, a 1.5 inch incision was utilized along the upper border of the rib below the 5th intercostal space at the anterior axillary line. TTs (sizes 28Fr, 32Fr, 36Fr and 40Fr were inserted and secured with both suturing and iTClamp techniques according to the preset randomization. TT were then functionally tested for positive and negative pressure as well as the force required to remove the TT (pull test-up to 5 lbs. Time to secure the TT was also recorded. Results: When sutured is placed by a trained surgeon, the sutures and iTClamp were functionally equivalent for holding a positive and negative pressure. Mean pull force for both sutures and iTClamp exceeded the 5 lb threshold; there was no significant difference between the groups. Securing the TT with the iTClamp was significantly faster (p < 0.0001 with the iTClamp having a mean application time of 37.0 ± 22.8 s and using a suture had a man application time of 96.3 ± 29.0 s. Conclusion: The iTClamp was effective in securing TTs. The main benefit to the iTClamp is that minimal skill is required to adequately secure a TT to ensure that it does not become dislodged during transport to a trauma center. Keywords: Chest tube, Tube thoracostomy, Securing chest tubes

  9. Experimental investigation of vortex control with an axial jet in the draft tube of a model pump-turbine

    Energy Technology Data Exchange (ETDEWEB)

    Kirschner, O; Schmidt, H; Ruprecht, A [Institute of Fluid Mechanics and Hydraulic Machinery, University of Stuttgart, Pfaffenwaldring 10, 70550 Stuttgart (Germany); Mader, R; Meusburger, P, E-mail: kirschner@ihs.uni-stuttgart.d [Vorarlberger Illwerke A G, atloggstrasse 36, 6780 Schruns (Austria)

    2010-08-15

    The operation of hydropower plants, especially of pump-storage plants, changes since the deregulation of the energy market. They are increasingly operating at off-design conditions in order to follow the demand in the electrical grid. Therefore the ability of hydropower plants handling the operation in a wide range of off-design conditions has become more important. In this context one problem is the vortex rope in the draft tube, especially for Francis turbines and pump-turbines running in part load. An experimental investigation in mitigation of the vortex rope phenomenon by injecting water axially in the centre of the draft tube on a pump-turbine model was carried out. Also the mitigation by additionally injected air in the centre of the draft tube was analysed. The results of the experimental investigation are focused on the reduction of the pressure fluctuations in the draft tube. In this paper two different part-load operating points were investigated. One of these operating points is a high part load operating point where a vortex rope exists. The other one is a low part load operating point, where the pressure fluctuation is not caused by a vortex rope. The results of the investigation show, that the injection of stabilizing water can mitigate the pressure fluctuation caused by a vortex rope. But the investigation of operating points where the pressure fluctuation is not caused by a vortex rope shows, that there is no significant reduction in the pressure fluctuation by this method. In these operating points the method of injecting additionally air reduces the pressure fluctuation better.

  10. photomultiplier tubes

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  11. photomultiplier tube

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  12. Effectiveness of the endotracheal tube cuff on the trachea: physical and mechanical aspects

    Directory of Open Access Journals (Sweden)

    Maira Soliani Del Negro

    2014-12-01

    Full Text Available Introduction: The inflation pressure of the endotracheal tube cuff can cause ischemia of the tracheal mucosa at high pressures; thus, it can cause important tracheal morbidity and tracheal microaspiration of the oropharyngeal secretion, or it can even cause pneumonia associated with mechanical ventilation if the pressure of the cuff is insufficient. Objective: In order to investigate the effectiveness of the RUSCH® 7.5 mm endotracheal tube cuff, this study was designed to investigate the physical and mechanical aspects of the cuff in contact with the trachea. Methods: For this end, we developed an in vitro experimental model to assess the flow of dye (methylene blue by the inflated cuff on the wall of the artificial material. We also designed an in vivo study with 12 Large White pigs under endotracheal intubation. We instilled the same dye in the oral cavity of the animals, and we analyzed the presence or not of leakage in the trachea after the region of the cuff after their deaths (animal sacrifice. All cuffs were inflated at the pressure of 30 cmH2O. Results: We observed the passage of fluids through the cuff in all in vitro and in vivo experimental models. Conclusion: We conclude that, as well as several other cuff models in the literature, the RUSCH® 7.5 mm tube cuffs are also not able to completely seal the trachea and thus prevent aspiration of oropharyngeal secretions. Other prevention measures should be taken.

  13. Strong, corrosion-resistant aluminum tubing

    Science.gov (United States)

    Reed, M. W.; Adams, F. F.

    1980-01-01

    When aluminum tubing having good corrosion resistance and postweld strength is needed, type 5083 alloy should be considered. Chemical composition is carefully controlled and can be drawn into thin-wall tubing with excellent mechanical properties. Uses of tubing are in aircraft, boats, docks, and process equipment.

  14. 21 CFR 872.6570 - Impression tube.

    Science.gov (United States)

    2010-04-01

    ... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6570 Impression tube. (a) Identification. An impression tube is a device consisting of a hollow copper tube intended to take an impression of a single tooth...) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in...

  15. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  16. In vitro pharmacokinetics of sirolimus-coated stent for tracheal stenosis

    African Journals Online (AJOL)

    Further increases in sirolimus: PLGA ratio did not improve stent drug loading. A slow release of ... tracheal stent can damage the airway mucosa, and cause .... Figure 3: Cumulative drug release from sirolimus-coated stents. DISCUSSION.

  17. Tracheal obstruction caused by an expandable metallic stent: a case of successful removal of the stent.

    Science.gov (United States)

    Okuyama, Hiroomi; Kubota, Akio; Kawahara, Hisayoshi; Oue, Takaharu; Nose, Satoko; Ihara, Toshiyuki

    2005-07-01

    We report a case of tracheal obstruction caused by an expandable metallic stent. A 3-month-old girl with severe tracheomalacia had a placement of a Palmaz stent. At 3 years of age, she developed progressive dyspnea. The CT scan showed tracheal obstruction caused by granulation tissue over the stent. At operation, the stent was found to have penetrated the posterior tracheal wall. Under partial cardiopulmonary bypass, the stent was removed along with the membranous wall of the trachea, and the trachea was reconstructed using slide tracheoplasty. Tracheal obstruction is one of the serious complications caused by an expandable metallic stent. Direct open approach to the trachea under cardiopulmonary bypass is thought to be a safe way to manage this problem.

  18. Association of two respiratory congenital anomalies: tracheal diverticulum and cystic adenomatoid malformation of the lung

    International Nuclear Information System (INIS)

    Restrepo, S.; Villamil, M.A.; Rojas, I.C.; Lemos, D.F.; Echeverri, S.; Angarita, M.; Triana, G.

    2004-01-01

    Many associations of congenital anomalies of the respiratory system have been reported, but the combination of tracheal diverticulum and cystic adenomatoid malformation (CCAM) is unique. We present a patient with these two anomalies and analyze their embryological correlation. (orig.)

  19. Heart Sound Localization and Reduction in Tracheal Sounds by Gabor Time-Frequency Masking

    OpenAIRE

    SAATCI, Esra; Akan, Aydın

    2018-01-01

    Background and aim: Respiratorysounds, i.e. tracheal and lung sounds, have been of great interest due to theirdiagnostic values as well as the potential of their use in the estimation ofthe respiratory dynamics (mainly airflow). Thus the aim of the study is topresent a new method to filter the heart sound interference from the trachealsounds. Materials and methods: Trachealsounds and airflow signals were collected by using an accelerometer from 10 healthysubjects. Tracheal sounds were then pr...

  20. Idiopathic tracheal stenosis: a clinicopathologic study of 63 cases and comparison of the pathology with chondromalacia.

    Science.gov (United States)

    Mark, Eugene J; Meng, Fanqing; Kradin, Richard L; Mathisen, Douglas J; Matsubara, Osamu

    2008-08-01

    Tracheal stenosis in adults usually is the result of mechanical injuries either from direct trauma or intubation. Rarely do cases develop in patients without such a precedent history, and there are few reports of the pathology of idiopathic tracheal stenosis (ITS). We reviewed clinicopathologically, 63 tracheal resections for tracheal stenosis in patients who had no antecedent explanation for their stenosis. We contrasted these 63 cases with 34 cases of tracheal stenosis owing to chondromalacia (CM) after mechanical injury. All 63 cases occurred in females, with a mean age of 49 years. The most common symptom was dyspnea on exertion. The average duration of symptoms was greater than 2 years. One-third of the patients gave a history of gastroesophageal reflux. All but one of the cases occurred in the subglottic region and/or upper one-third of the trachea. Pathologically, most cases showed extensive keloidal fibrosis and dilation of mucus glands, a finding that was not obvious in most cases of CM. ITS has relatively normal cartilage with smooth inner and outer perichondrium, whereas CM has extensive degeneration of cartilage with irregular border of inner perichondrium observable at shirt sleeve magnification. Immunohistochemical staining for estrogen receptor and progesterone receptor was positive in fibroblasts cells in most cases. ITS is a rare disease and restricted to females. It may represent some form of fibromatosis. ITS can be distinguished histologically from CM in tracheal resection specimens in most cases.

  1. Comparative study of the Quality Control of x-ray tubes and generators in hospital assistance and primary assistance in Galician autonomous community

    International Nuclear Information System (INIS)

    Pombar Camean, M.; Lobato Busto, R.

    1992-01-01

    The quality guarantee in Diagnostic Radiology is defined as the organized effort of surgical staff to guarantee sufficient quality images, which provide the correct diagnostic information, as cheaply as possible and with the least exposure to radiation for the patient. In this paper a comparative study about the quality control of x-ray tube and generators in hospital assistance and primary assistance is present. In the conclusions, it is confirmed that the antiquity and poor conservation of the primary attendance x-ray equipment, have influence on the studied constants and therefore, influence the doses received by the patients. (author)

  2. The effect of nitroglycerin on response to tracheal intubation. Assessment by radionuclide angiography

    International Nuclear Information System (INIS)

    Hart, A.P.; Camporesi, E.M.; Sell, T.L.; Croughwell, N.; Silva, R.; Jones, R.H.; McIntyre, R.W.; Stanley, T.E.; Reves, J.G.

    1989-01-01

    The effect of intravenous (IV) nitroglycerin (NTG) on perioperative myocardial ischemia as detected by single pass radionuclide angiocardiography was studied in 20 patients scheduled for elective coronary artery bypass grafting (CABG). Ten patients, selected at random, received IV NTG 1 microgram.kg-1.min-1 (NTG group) and 10 others, IV saline (control group). Anesthetic induction consisted of midazolam 0.2 mg.kg-1, vecuronium 0.1 mg.kg-1, and 50% N 2 O in O 2 . ECG leads I, II, and V5 were monitored for ST segment changes. Single pass radionuclide angiocardiography (RNA) was performed at 5 times: prior to induction, prior to tracheal intubation, and at 1, 3.5, and 6 min following intubation. The presence of new regional wall motion abnormalities (RWMA) was determined from each RNA study as compared with the preinduction measurement. Apart from one patient in the control group who developed a new ''v'' wave after intubation, there was no evidence of ischemia by pulmonary capillary wedge pressure. No ECG evidence of ischemia was detected in any patient. Despite this, new regional wall motion abnormalities were observed in 3 patients in the control group and 1 patient in the NTG group. Blood pressure and heart rate responses of patients with new RWMA were not significantly different from other patients. The low incidence of ischemia in this population precludes a definitive statement regarding the efficacy of IV NTG, but the lower incidence of RWMA in the NTG group suggests a protective effect

  3. Design and implementation of a control system to improve the quality of the combustion gases in the fire-tube boiler of 5 BHP

    Directory of Open Access Journals (Sweden)

    Carlos Alfredo Pérez Albán

    2016-06-01

    Full Text Available The goal of this paper is the design and implementation of a system for controlling the quality of the combustion gases in a fire-tube boiler of 5 BHP. Based on the percentage of O2 present in the combustion gases, measured by a lambda sensor, the percentage of CO2 emitted into the atmosphere is determined. PID proportional control is responsible for the automatic regulation of the entry of air to the boiler by an actuator, according to the percentage of the oxygen concentration in the combustion gases. The control system has an HMI display and a modular PLC. The results achieved ensure pollutant gases emissions within the parameters established by current environmental standards, achieving the required quality of combustion gases and reducing the fuel consumption of the boiler.

  4. Recurrent inspection of tubes

    International Nuclear Information System (INIS)

    Andersson, S.

    1984-01-01

    Recommendations concerning the selection of areas for the inspection of tubes have been outlined. The aim is to focus the control on the regions which are important for the safety and where damage is supposed to take place. The number of zones will depend on the risk factors as judged by experts. The localizing will be based upon probable damaging mechanisms. A certain number of areas should be chosen at random. (G.B.)

  5. Cathode ray tube

    International Nuclear Information System (INIS)

    1979-01-01

    A cathode ray tube comprises two electron lens means in combination to crossover the electron beam at a second crossover between the two electron lens means with one of the two lens means having a variable voltage applied thereto to control the location of the beam crossover in order to focus the beam onto a display screen at any location away from the screen center. (Auth.)

  6. Tracheal intubation in critically ill patients: a comprehensive systematic review of randomized trials.

    Science.gov (United States)

    Cabrini, Luca; Landoni, Giovanni; Baiardo Radaelli, Martina; Saleh, Omar; Votta, Carmine D; Fominskiy, Evgeny; Putzu, Alessandro; Snak de Souza, Cézar Daniel; Antonelli, Massimo; Bellomo, Rinaldo; Pelosi, Paolo; Zangrillo, Alberto

    2018-01-20

    We performed a systematic review of randomized controlled studies evaluating any drug, technique or device aimed at improving the success rate or safety of tracheal intubation in the critically ill. We searched PubMed, BioMed Central, Embase and the Cochrane Central Register of Clinical Trials and references of retrieved articles. Finally, pertinent reviews were also scanned to detect further studies until May 2017. The following inclusion criteria were considered: tracheal intubation in adult critically ill patients; randomized controlled trial; study performed in Intensive Care Unit, Emergency Department or ordinary ward; and work published in the last 20 years. Exclusion criteria were pre-hospital or operating theatre settings and simulation-based studies. Two investigators selected studies for the final analysis. Extracted data included first author, publication year, characteristics of patients and clinical settings, intervention details, comparators and relevant outcomes. The risk of bias was assessed with the Cochrane Collaboration's Risk of Bias tool. We identified 22 trials on use of a pre-procedure check-list (1 study), pre-oxygenation or apneic oxygenation (6 studies), sedatives (3 studies), neuromuscular blocking agents (1 study), patient positioning (1 study), video laryngoscopy (9 studies), and post-intubation lung recruitment (1 study). Pre-oxygenation with non-invasive ventilation (NIV) and/or high-flow nasal cannula (HFNC) showed a possible beneficial role. Post-intubation recruitment improved oxygenation , while ramped position increased the number of intubation attempts and thiopental had negative hemodynamic effects. No effect was found for use of a checklist, apneic oxygenation (on oxygenation and hemodynamics), videolaryngoscopy (on number and length of intubation attempts), sedatives and neuromuscular blockers (on hemodynamics). Finally, videolaryngoscopy was associated with severe adverse effects in multiple trials. The limited available

  7. Recurrent airway obstructions in a patient with benign tracheal stenosis and a silicone airway stent: a case report

    OpenAIRE

    Sriram, KB; Robinson, PC

    2008-01-01

    Airway stents (silicone and metal stents) are used to treat patients with benign tracheal stenosis, who are symptomatic and in whom tracheal surgical reconstruction has failed or is not appropriate. However airway stents are often associated with complications such as migration, granuloma formation and mucous hypersecretion, which cause significant morbidity, especially in patients with benign tracheal stenosis and relatively normal life expectancy. We report a patient who had frequent critic...

  8. Traumatic tracheal diverticulum corrected with resection and anastomosis during one-lung ventilation and total intravenous anesthesia in a cat.

    Science.gov (United States)

    Sayre, Rebecca S; Lepiz, Mauricio; Wall, Corey; Thieman-Mankin, Kelley; Dobbin, Jennifer

    2016-11-01

    This report describes the clinical findings and diagnostic images of a traumatic intrathoracic tracheal avulsion with a tracheal diverticulum in a cat. Furthermore, a complete description of the tracheal resection and anastomosis using one-lung ventilation (OLV) with total and partial intravenous anesthesia is made. A 3-year-old neutered male domestic shorthair cat weighing 6.8 kg was presented to the University Teaching Hospital for evaluation of increased respiratory noise 3 months following unknown trauma. Approximately 12 weeks prior to presentation, the cat had been seen by the primary care veterinarian for respiratory distress. At that time, the cat had undergone a tracheal ballooning procedure for a distal tracheal stricture diagnosed by tracheoscopy. The tracheal ballooning had provided only temporary relief. At presentation to our institution, the cat had increased respiratory effort with harsh upper airway noise auscultated during thoracic examination. The remainder of the physical examination was normal. Diagnostics included a tracheoscopy and a thoracic computed tomographic examination. The cat was diagnosed with tracheal avulsion, pseudotrachea with a tracheal diverticulum, and stenosis of the avulsed tracheal ends. Surgical correction of the tracheal stricture via a thoracotomy was performed using OLV with total and partial intravenous anesthesia. The cat recovered uneventfully and at last follow-up was active and doing well. This case report describes OLV using standard anesthesia equipment that is available at most private practices. Furthermore, this case describes the computed tomographic images of the intrathoracic tracheal avulsion and offers a positive outcome for tracheal resection and anastomosis. © Veterinary Emergency and Critical Care Society 2015.

  9. Questioning the wisdom of tubeless percutaneous nephrolithotomy (PCNL): a prospective randomized controlled study of early tube removal vs tubeless PCNL.

    Science.gov (United States)

    Mishra, Shashikant; Sabnis, Ravindra B; Kurien, Abraham; Ganpule, Arvind; Muthu, Veeramani; Desai, Mahesh

    2010-10-01

    To establish the efficacy of early removal of a nephrostomy tube after percutaneous nephrolithotomy (PCNL), to challenge the wisdom of tubeless PCNL, as we hypothesized that it would result in a shorter hospital stay, comparable benefit and safety, while maintaining the option of check nephroscopy ensuring far superior stone clearance. In all, 22 patients were prospectively randomized equally into two groups, group 1 (early nephrostomy removal) or group 2 (tubeless) during a 1-month study period. Inclusion criteria for the study were: a simple stone of Foley catheter were used, while in group 2 only a 6 F retrograde ureteric catheter and Foley catheter were placed at the end of the procedure. Computed tomography (CT) with no contrast medium was done on the first morning after surgery before removing all catheters/tubes, and patients discharged subsequently. The variables assessed were stone clearance, hospital stay, analgesic requirement, postoperative complications and auxiliary procedures. The mean (SD) stone bulk was similar between the groups, at 2737 (946.9) and 2934.2 (2090.7) µL, respectively. Despite an on-table complete clearance, clearance assessed by CT was nine of 11 vs eight of 11 in groups 1 and 2, respectively. CT showed a 6 mm stone in one patient in group 1, while the remaining patients had stones of haematuria in none vs three (P= 0.21), urinoma none vs one, and fever in two vs one, respectively; one patient in group 1 required a check nephroscopy for a residual fragment. Overall clearance including re-treatment was 10/11 vs eight of 11 (P= 0.009), respectively. Early tube removal after PCNL results in an equivalent analgesic requirement, decrease in haemoglobin and hospital stay as tubeless PCNL. It has a significantly lower incidence of early haematuria, better clearance rates and preserves the option of check nephroscopy. It can be considered as an accepted standard of care, with the preserved advantages of tubeless PCNL. © 2010 THE AUTHORS

  10. Effects of perfluorooctane sulfonate on tracheal ciliary beating frequency in mice

    International Nuclear Information System (INIS)

    Matsubara, Eriko; Nakahari, Takashi; Yoshida, Hideyo; Kuroiwa, Toshihiko; Harada, Kouji H.; Inoue, Kayoko; Koizumi, Akio

    2007-01-01

    Perfluorooctane sulfonate (PFOS) is one of the emerging persistent organic pollutants, ubiquitously found in the global environment, even in human serum. PFOS has been reported to perturb Ca 2+ homeostasis in Paramecium, cardiomyocytes and neurons. Since ciliary beat frequency (CBF) in the trachea is known to be increased by cytoplasmic Ca 2+ elevation, the effects of PFOS on CBF were evaluated in a slice preparation using video-enhanced contrast microscopy. PFOS increased CBF by 11% (P 2+ concentration ([Ca 2+ ] i ) in mouse tracheal ciliary cells. In Ca 2+ -free solution, PFOS at 100 μM failed to increase CBF (0.96-fold of vehicle control). The addition of Gd 3+ (1 μM), a store-operated Ca 2+ channel blocker, did not prevent the increase in CBF (1.09-fold (P + concentration (50 mM), which causes depolarization of the plasma membrane potential and a transient increase in [Ca 2+ ] i , increased CBF by 20% (P 2+ channels (VDCCs) in stimulation of CBF. Nifedipine (30 μM), a selective VDCC blocker, antagonized the effects of high K + (0.92-fold of high K + solution) and PFOS (0.96-fold of vehicle control) on CBF. In cells from peroxisome proliferator-activated receptor α (PPARα)-null mice, PFOS still increased CBF (1.12-fold (P 2+ through VDCC

  11. Large-segment tracheal resection and interannular anastomosis with a tension-release technique in the dog.

    Science.gov (United States)

    Dallman, M J; Bojrab, M J

    1982-02-01

    Tracheal resection and anastomosis were done on 7 dogs, and a modified procedure to provide optimum first-intention healing, minimum connective tissue proliferation, and optimum epithelialization was used. To test the integrity of the technique at high incision-line tensile forces, 15 to 17 tracheal rings were excised. Excessive tracheal manipulation resulted in an increased amount of lamina propria and submucosa collagenous tissue, increased size and number of blood vessels, and increased leukocytic invasion. Criteria for a successful anastomosis were minimum postoperative coughing, good mucosal apposition and epithelialization, and tracheal lumen diameters that were at least 80% of the preoperative measurement.

  12. Front-end circuit for position sensitive silicon and vacuum tube photomultipliers with gain control and depth of interaction measurement

    International Nuclear Information System (INIS)

    Herrero, Vicente; Colom, Ricardo; Gadea, Rafael; Lerche, Christoph W.; Cerda, Joaquin; Sebastia, Angel; Benlloch, Jose M.

    2007-01-01

    Silicon Photomultipliers, though still under development for mass production, may be an alternative to traditional Vacuum Photomultipliers Tubes (VPMT). As a consequence, electronic front-ends initially designed for VPMT will need to be modified. In this simulation, an improved architecture is presented which is able to obtain impact position and depth of interaction of a gamma ray within a continuous scintillation crystal, using either kind of PM. A current sensitive preamplifier stage with individual gain adjustment interfaces the multi-anode PM outputs with a current division resistor network. The preamplifier stage allows to improve front-end processing delay and temporal resolution behavior as well as to increase impact position calculation resolution. Depth of interaction (DOI) is calculated from the width of the scintillation light distribution, which is related to the sum of voltages in resistor network input nodes. This operation is done by means of a high-speed current mode scheme

  13. Feeding tube - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007235.htm Feeding tube - infants To use the sharing features on this page, please enable JavaScript. A feeding tube is a small, soft, plastic tube placed ...

  14. Experimental study of different nickel-titanium memory tracheal stents in dogs

    International Nuclear Information System (INIS)

    Lang Xu; He Nengshu; Fan Hailun

    2009-01-01

    Objective: Since membrane -covered metal tracheal stent was applied successfully to treat the airway stenosis, it has been widely used and obtained satisfactory result during the past years. The purpose of our study was provide theoretical rational for treatment with membrane-covered tracheal stent by using animal experiment. Methods: The nickel- titanium memory stents of 22 mm in diameter and 6 cm in length were deployed in 18 dogs. The dogs were grouped into full- length membrane-covered group (n=6), partial-length membrane-covered group (membrane was covered for 4 cm in the medial part of the stent, n=6), and naked stent group (n=6). After the stent placement dysphagia or dysphonia was monitored daily. Twenty-four weeks later, the dogs were executed. Speiments were taken from the cephalic, medial, and caudal trachea under the stent. HE stain and proliferating cell nuclear antigen (PCNA) were evaluated. Results: After the stent placement, no dyspnea, dysphagia or dysphonia but cough was present in each dog. There was no significant difference in symptom between the three groups. Inflammation reaction, metaplasia from low columnar epithelium to spuamous epithelium, and mild granulation tissue hyperplasia in the underlying mucosa were present in each group. However, fibrosis and tracheal straitness were present only in the non-membrane-covered area, but not in the membrane-covered area. More PCNA expression was observed in the non-membrane -covered area than in the membrane-covered area. Conclusion: Both membrane-covered and non-membrane-covered stents can cause similar symptoms. However, the membrane -covered tracheal stent has good biological compatibility and would not induce tracheal straitness. The non-membrane -covered tracheal stent could induce a severe pathologic reaction and tracheal straitness. (authors)

  15. An in vitro comparison of tracheostomy tube cuffs

    Directory of Open Access Journals (Sweden)

    Maguire S

    2015-04-01

    Full Text Available Seamus Maguire,1 Frances Haury,2 Korinne Jew2 1Research and Development, Covidien Respiratory and Monitoring Solutions, Athlone, Ireland; 2Medical Affairs, Covidien Respiratory and Monitoring Solutions, Boulder, CO, USA Introduction: The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT] with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force.Methods: Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O, instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site.Results: The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05. The taper

  16. R+-methanandamide inhibits tracheal response to endogenously released acetylcholine via capsazepine-sensitive receptors.

    Science.gov (United States)

    Nieri, Paola; Martinotti, Enrica; Testai, Lara; Adinolfi, Barbara; Calderone, Vincenzo; Breschi, Maria Cristina

    2003-01-10

    The effects of cannabinoid drugs on the cholinergic response evoked by electrical field stimulation (0.2 ms pulse width, 20 V amplitude, 10 Hz, 7.5 s train duration) in guinea-pig tracheal preparations were investigated. The stable analogue of the endocannabinoid anandamide, R(+)-methanandamide (10(-7)-10(-4) M), produced a dose-dependent inhibition (up to 27+/-5% of control) of electrical field stimulation-mediated atropine-sensitive response. This effect was not blocked by the selective cannabinoid CB(1) receptor antagonist N-(piperidin-1-yl)-5-(4-chlorophenyl)-1-(2,4-dichlorophenyl)-4-methyl-1H-pyrazole-3 carboxamide hydrochloride (SR 141716A; 10(-6) M), and was not reproduced with the cannabinoid CB(1)/CB(2) receptor agonist R(+)-[2,3-dihydro-5-methyl-[(morpholinyl)methyl]pyrrolo [1,2,3-de]-1,4-benzoxazin-6-yl]-(1-naphthalenyl)methanone mesylate) (WIN 55,212-2; 10(-8)-10(-5) M) or the cannabinoid CB(2) receptor selective agonist 1-propyl-2-methyl-3-(1-naphthoyl)indole (JWH-015; 10(-8)-10(-5) M); it was, on the contrary, antagonized by the vanilloid antagonist 2-[2-(4-chlorophenyl)ethyl-amino-thiocarbonyl]-7,8-dihydroxy-2,3,4,5-tetrahydro-1H-2 benzazepine (capsazepine; 10(-6) M). At the postjunctional level, neither R(+)-methanandamide nor WIN 55,212-2 nor JWH-015 did affect tracheal contractions induced by exogenous acetylcholine (10(-6) M). An inhibitory vanilloid receptor-mediated effect on the cholinergic response evoked by electrical stimulation was confirmed with the vanilloid agonist capsaicin, at doses (3-6 x 10(-8) M) which poorly influenced the basal smooth muscle tone of trachea. In conclusion, our data indicate that in guinea-pig trachea (a) neither CB(1) nor CB(2) cannabinoid receptor-mediated modulation of acetylcholine release occurs; (b) vanilloid VR1-like receptors appear involved in R(+)-methanandamide inhibitory activity on the cholinergic response to electrical field stimulation.

  17. Tube holding system

    International Nuclear Information System (INIS)

    Cunningham, R.C.

    1978-01-01

    A tube holding rig is described for the lateral support of tubes arranged in tight parcels in a heat exchanger. This tube holding rig includes not less than two tube supporting assemblies, with a space between them, located crosswise with respect to the tubes, each supporting assembly comprising a first set of parallel components in contact with the tubes, whilst a second set of components is also in contact with the tubes. These two sets of parts together define apertures through which the tubes pass [fr

  18. Alleviating stress response to tracheal extubation in neurosurgical patients: A comparative study of two infusion doses of dexmedetomidine

    Directory of Open Access Journals (Sweden)

    Ankur Luthra

    2017-01-01

    Full Text Available Background: Tracheal extubation is almost always associated with increase in sympathoadrenal activity may result in hypertension, tachycardia, and arrhythmias. Attempts have been made to oppose the pressor response by the use of various drugs. Dexmedetomidine decreases norepinephrine which reduces the blood pressure and the heart rate (HR. We hypothesize that the infusion of dexmedetomidine may produce more stable hemodynamics during extubation as compared to boluses. Materials and Methods: Ninety adult patients aged 18–65 years, the American Society of Anesthesiologists Grade I–II undergoing intracranial surgeries for various neurologic problem at All India Institute of Medical Sciences were enrolled in this randomized controlled trial. Primary Objectives: (1 To observe the hemodynamic changes (HR and mean arterial pressure [MAP] and airway responses during tracheal extubation following two infusion doses of dexmedetomidine. Secondary Objectives: (1 Time to emergence and time to tracheal extubation, (2 Early postoperative complications such as laryngospasm and bronchospasm, and (3 adverse effects of the study drug. Patients were assigned into three groups – (1 Group D0.2 – 0.2 μg/kg/h diluted to 50 ml, (2 Group D0.4 – 0.4 μg/kg/h diluted to 50 ml and Group P (Placebo – 0.9% NS 50 ml. The hemodynamics including the HR and MAP were recorded just before the loading dose of the study drug and then were recorded every 5 min till the infusion was stopped at tracheal extubation and every 1 min till 10 min postextubation. In addition, the airway, respiratory and cardiovascular complications along with postoperative nausea and vomiting, shivering, cough grading, Aldrete score, Ramsay sedation scale, and intraoperative awareness were recorded. Statistical Analysis: Continuous variables such as HR and MAP were analyzed using analysis of variance and categorical variables were analyzed using the Chi-square test. Results: Patient demographics

  19. A portable tube exciting X-ray fluorescence analysis system

    International Nuclear Information System (INIS)

    Yang Qiang; Lai Wanchang; Ge Liangquan

    2009-01-01

    Article introduced a portable tube exciting X-ray fluorescence analysis system which is based on arm architecture. Also, we designed Tube control circuit and finished preliminary application. The energy and the intensity of the photon can be adjusted continuously by using the tube. Experiments show that high excitation efficiency obtained by setting the appropriate parameters of the tube for the various elements. (authors)

  20. A systematic review and meta-regression analysis of mivacurium for tracheal intubation.

    Science.gov (United States)

    Vanlinthout, L E H; Mesfin, S H; Hens, N; Vanacker, B F; Robertson, E N; Booij, L H D J

    2014-12-01

    We systematically reviewed factors associated with intubation conditions in randomised controlled trials of mivacurium, using random-effects meta-regression analysis. We included 29 studies of 1050 healthy participants. Four factors explained 72.9% of the variation in the probability of excellent intubation conditions: mivacurium dose, 24.4%; opioid use, 29.9%; time to intubation and age together, 18.6%. The odds ratio (95% CI) for excellent intubation was 3.14 (1.65-5.73) for doubling the mivacurium dose, 5.99 (2.14-15.18) for adding opioids to the intubation sequence, and 6.55 (6.01-7.74) for increasing the delay between mivacurium injection and airway insertion from 1 to 2 min in subjects aged 25 years and 2.17 (2.01-2.69) for subjects aged 70 years, p < 0.001 for all. We conclude that good conditions for tracheal intubation are more likely by delaying laryngoscopy after injecting a higher dose of mivacurium with an opioid, particularly in older people. © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  1. Effect of Nebivolol on tone of tracheal muscle of guinea pig

    International Nuclear Information System (INIS)

    Shaukat, A.; Sharif, M.; Najmi, M.H.

    2015-01-01

    Background: The use of β-blockers is limited by adverse effects such as bronchospasm in asthmatics. Third generation beta-blockers such as nebivolol may show better tolerability in asthmatic subjects because they lack β-blocker induced bronchoconstriction. Method: Effects of nebivolol on the tracheal muscle strips prepared from ovalbumin-sensitised guinea pigs of both sexes were studied. Two sets of experiments were designed after dividing the animals randomly into two groups. Using oxygenated Krebs-Henseleit solution as the nutrient medium, the trachealis muscle activity was measured with isometric force displacement transducer and recorded on 4-channel Oscillograph. Results: Nebivolol 10(-6) M did not produce significant effect on contractions evoked by histamine in concentrations ranging from 10/su -7/ M to 10/sup -3/ M. The mean of amplitude of contraction for different concentrations of histamine were calculated and compared with the group treated with histamine only. Mean of amplitude of contraction, percent responses and percent deviations when compared with the control group were insignificant (p>0.05). Conclusion: Nebivolol did not affect the tone of airway smooth muscle in ovalbumin-sensitised guinea pigs. Nebivolol may be considered safe in patients with airway disease however, further clinical evaluation and exploratory work is required. (author)

  2. Association between pathogens from tracheal aspirate and oral biofilm of patients on mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Luana Carneiro Diniz SOUZA

    2017-06-01

    Full Text Available Abstract The aim of this study was to detect possible associations between respiratory pathogens from tracheal aspirate and oral biofilm samples in intubated patients in an intensive care unit (ICU, and to identify the most common respiratory pathogens in oral biofilm, particularly in patients that developed ventilator-associated pneumonia (VAP. Two oral biofilm samples were collected from the tongue of intubated patients (at admission and after 48 hours and analyzed by culture with the Antibiotic Sensitivity Test. The results from the tongue biofilm samples were compared with the tracheal secretions samples. A total of 59.37% of patients exhibited the same species of pathogens in their tracheal aspirate and oral biofilm, of which 8 (42.1% developed VAP, 10 (52.63% did not develop pneumonia and one (5.26% had aspiration pneumonia. There was a statistically significant association between presence of microorganisms in the tracheal and mouth samples for the following pathogens: Klebsiella pneumoniae, Candida albicans, Pseudomonas aeruginosa, Enterobacter gergoviae, Streptococcus spp and Serratia marcescens (p < 0.05. Pathogens that are present in tracheal aspirates of intubated patients can be detected in their oral cavity, especially in those who developed VAP or aspiration pneumonia. Thus, the results indicate that an improved oral care in these patients could decrease ICU pneumonia rates.

  3. Fracture of an endoluminal nitinol stent used in the treatment of tracheal collapse in a dog.

    Science.gov (United States)

    Mittleman, Elise; Weisse, Chick; Mehler, Stephen J; Lee, Justine A

    2004-10-15

    A 5-year-old castrated male Pomeranian was evaluated because of severe dyspnea and coughing, and a diagnosis of complete, static collapse of the trachea at the thoracic inlet was made. After failure to improve with medical management alone, an endoluminal tracheal stent was placed, which resulted in resolution of signs. Ten weeks after stent placement, the dog underwent tracheal resection and anastomosis because the stent had fractured at the level of the thoracic inlet. One year after surgery, the dog was doing well and required treatment with hydrocodone infrequently. Compared with other surgical treatment options, placement of an endoluminal tracheal stent is a relatively noninvasive intervention that can provide effective relief from the clinical signs associated with tracheal collapse in dogs. Implantation of endoluminal tracheal stents may be associated with complications; therefore, the procedure may best be regarded as a salvage procedure for dogs with end-stage disease that are refractory to appropriate medical management, have extensive collapse of the intrathoracic portion of the trachea, or are poor candidates for surgery.

  4. Tracheostomy Tube Ignition During Microlaryngeal Surgery Using Diode Laser: A Case Report

    Directory of Open Access Journals (Sweden)

    Hsun-Mo Wang

    2006-04-01

    Full Text Available Ignition of the tracheal tube during laser microlaryngeal surgery under general anesthesia is an uncommon complication with potentially serious consequences. We present here a case of a patient with glottic stenosis following endotracheal intubation, who experienced this potentially catastrophic combustion during endoscopic arytenoidectomy, using a diode laser under general anesthesia via 60% FiO2, with an airway fire occurring at the tracheostomy tube and causing tubal damage and obstruction. The anesthetic connecting tube was immediately disconnected and the tracheostomy tube replaced. No adverse consequences to this patient's upper airway were noted during follow-up visits. Higher oxygen concentrations, the presence of combustibles, and the narrowness of the surgical field during endolaryngeal diode laser surgery are risk factors for airway fires.

  5. An unusual tracheal foreign body in a neonate

    International Nuclear Information System (INIS)

    Horimoto, Y.; Kasuya, T.; Yoshizawa, M.; Okazaki, A.; Ito, H.; Shimura, K.

    1986-01-01

    Tracheobronchial foreign bodies are still a major problem in infancy. Eighty percent of them are observed in children below the age of 3 years, but they are quite rare in neonates. The extraction of the tube tip, which had been used as a means of medical management during respiratory care, is reported. (orig.)

  6. TO STUDY EFFECT OF GABAPENTIN ON ATTENUATION OF PRESSOR RESPONSE TO DIRECT LARYNGOSCOPY AND TRACHEAL INTUBATION AND ON PERIOPERATIVE PAIN

    Directory of Open Access Journals (Sweden)

    Sarita Chandapet

    2017-05-01

    Full Text Available BACKGROUND Endotracheal intubation was first described by Rowbotham and Magill in 1921. 1 In 1940 Reid and Brace first described hemodynamic response to Laryngoscopy and Intubation due to Noxious stimuli. 2 The circulatory responses to laryngeal and tracheal stimulation are due to sympathoadrenal stimulation. 3 Laryngoscopy and Tracheal Intubation induces changes in circulating Catecholamine levels significantly. Norepinephrine, Epinephrine and Dopamine levels rise, but the raise in Norepinephrine levels is consistently associated with elevation of Blood pressure and Heart rate. 4 Even though the elevation in Blood pressure and Heart rate due to Laryngoscopy and Intubation are brief, they may have detrimental effects in high risk patients including Myocardial Infarction, Cardiac failure, Intracranial haemorrhage and increases in Intracranial pressure. 5 Many strategies have been advocated to minimize these hemodynamic adverse responses and aimed at different levels of the reflex arc. 6 Block of the peripheral sensory receptors and afferent input is by topical application and infiltration of Local Anaesthetic to Superior laryngeal nerve. Block of central mechanism of integration and sensory input by drugs like Fentanyl, Morphine etc. Block of efferent pathway and effector sites IV Lignocaine, Beta blockers, Calcium channel blockers, Hydralazine etc. No single drug or technique is satisfactory. The aim of this study is to evaluate the efficacy of Gabapentin in attenuating hemodynamic response to laryngoscopy and intubation in a placebo controlled double blind study. MATERIALS AND METHODS A clinical comparative study of attenuation of sympathetic response to laryngoscopy and intubation was done in 150 patients posted for elective surgery divided into two groups and were randomly allocated Group 1 – placebo capsules with sugar and Group 2 – Gabapentin 300 mg capsules. Heart rate, systolic, diastolic blood pressure, mean arterial pressure were

  7. Inhibitor production by normal rat tracheal epithelial cells influences the frequency of spontaneous and X-ray-induced enhanced growth variants

    International Nuclear Information System (INIS)

    Terzaghi-Howe, M.

    1989-01-01

    A cell culture model was used to assay for the induction of cell populations with enhanced growth capacity in culture in irradiated normal rat tracheal epithelial cells (NTEC). Some growth conditions appear to favor the proliferation of both normal and carcinogen-exposed populations, while others appear to select for populations previously exposed to carcinogen. In the present report we focus on what growth conditions are critical for controlling the emergence of spontaneous and X-ray induced proliferating epithelial foci (PEF) and what factor(s) directly influences the relative frequency of PEF in irradiated and control NTEC cultures. (author)

  8. Effects of Fentanyl-lidocaine-propofol and Dexmedetomidine-lidocaine-propofol on Tracheal Intubation Without Use of Muscle Relaxants

    Directory of Open Access Journals (Sweden)

    Volkan Hancı

    2010-05-01

    Full Text Available The aim of this study was to compare the effects of fentanyl or dexmedetomidine when used in combination with propofol and lidocaine for tracheal intubation without using muscle relaxants. Sixty patients with American Society of Anesthesiologists stage I risk were randomized to receive 1 mg/kg dexmedetomidine (Group D, n = 30 or 2 mg/kg fentanyl (Group F, n = 30, both in combination with 1.5 mg/kg lidocaine and 3 mg/kg propofol. The requirement for intubation was determined based on mask ventilation capability, jaw motility, position of the vocal cords and the patient's response to intubation and inflation of the endotracheal tube cuff. Systolic arterial pressure, mean arterial pressure, heart rate and peripheral oxygen saturation values were also recorded. Rate pressure products were calculated. Jaw relaxation, position of the vocal cords and patient's response to intubation and inflation of the endotracheal tube cuff were significantly better in Group D than in Group F (p < 0.05. The intubation conditions were significantly more satisfactory in Group D than in Group F (p = 0.01. Heart rate was significantly lower in Group D than in Group F after the administration of the study drugs and intubation (p < 0.05. Mean arterial pressure was significantly lower in Group F than in Group D after propofol injection and at 3 and 5 minutes after intubation (p < 0.05. After intubation, the rate pressure product values were significantly lower in Group D than in Group F (p < 0.05. We conclude that endotracheal intubation was better with the dexmedetomidine–lidocaine–propofol combination than with the fentanyl–lidocaine–propofol combination. However, side effects such as bradycardia should be considered when using dexmedetomidine.

  9. RESONANCE CONTROL FOR THE COUPLED CAVITY LINAC AND DRIFT TUBE LINAC STRUCTURES OF THE SPALLATION NEUTRON SOURCE LINAC USING A CLOSED-LOOP WATER COOLING SYSTEM

    International Nuclear Information System (INIS)

    Bernardin, J.D.; Brown, R.L.

    2001-01-01

    The Spallation Neutron Source (SNS) is a facility being designed for scientific and industrial research and development. SNS will generate and use neutrons as a diagnostic tool for medical purposes, material science, etc. The neutrons will be produced by bombarding a heavy metal target with a high-energy beam of protons, generated and accelerated with a linear particle accelerator, or linac. The low energy end of the linac consists of two room temperature copper structures, the drift tube linac (DTL), and the coupled cavity linac (CCL). Both of these accelerating structures use large amounts of electrical energy to accelerate the protons to an energy of 185 MeV. Approximately 60-80% of the electrical energy is dissipated in the copper structure and must be removed. This is done using specifically designed water cooling passages within the linac's copper structure. Cooling water is supplied to these cooling passages by specially designed resonance control and water cooling systems

  10. Combination of helical ferritic-steel inserts and flux-tube-expansion divertor for the heat control in tokamak DEMO reactor

    International Nuclear Information System (INIS)

    Takizuka, T.; Tokunaga, S.; Hoshino, K.; Shimizu, K.; Asakura, N.

    2015-01-01

    Edge localized modes (ELMs) in the H-mode operation of tokamak reactors may be suppressed/mitigated by the resonant magnetic perturbation (RMP), but RMP coils are considered incompatible with DEMO reactors under the strong neutron flux. We propose an innovative concept of the RMP without installing coils but inserting ferritic steels of the helical configuration. Helically perturbed field is naturally formed in the axisymmetric toroidal field through the helical ferritic steel inserts (FSIs). When ELMs are avoided, large stationary heat load on divertor plates can be reduced by adopting a flux-tube-expansion (FTE) divertor like an X divertor. Separatrix shape and divertor-plate inclination are similar to those of a simple long-leg divertor configuration. Combination of the helical FSIs and the FTE divertor is a suitable method for the heat control to avoid transient ELM heat pulse and to reduce stationary divertor heat load in a tokamak DEMO reactor

  11. Tracheal epithelial-myoepithelial carcinoma associated with sarcoid-like reaction: A case report

    Science.gov (United States)

    Dong, Huawei; Tatsuno, Brent K.; Betancourt, Jaime; Oh, Scott S.

    2014-01-01

    Epithelial-myoepithelial carcinomas are rare tumors that primarily originate in the salivary glands but have also been found in the tracheobronchial tree. We report the first case of epithelial-myoepithelial carcinoma associated with sarcoidosis. A 61 year old Hispanic man presented with altered mental status and hypercalcemia. Imaging revealed diffuse intra-thoracic and intra-abdominal lymphadenopathy. A diagnostic bronchoscopy was performed where an incidental tracheal nodule was discovered and biopsied. Pathology was consistent with epithelial-myoepithelial carcinoma. Lymph node biopsy demonstrated non-caseating granulomas consistent with sarcoidosis. Patient underwent tracheal resection of the primary tumor with primary tracheal reconstruction. Hypercalcemia subsequently normalized with clinical improvement. Repeat CT imaging demonstrated complete resolution of lymphadenopathy. Our findings are suggestive of a possible paraneoplastic sarcoid-like reaction to the epithelial-myoepithelial carcinoma with associated lymphadenopathy and symptomatic hypercalcemia. PMID:26029574

  12. Thyroidectomy improves tracheal anatomy and airflow in patients with nodular goiter

    DEFF Research Database (Denmark)

    Sørensen, Jesper Roed; Lauridsen, Jeppe Killerich; Døssing, Helle

    . Effect sizes (ES) were calculated as mean change divided by standard deviation at baseline. ES of 0.2-0.5 were defined as small, 0.5-0.8 as moderate, and values >0.8 as large. Results: Sixty-five patients completed all examinations. Median goiter volume was 58 mL (range, 14-642 mL) before surgery...... resonance images (MRI) of the neck and respiratory flow-volume curves, including both in- and expiration, were performed prior to and six months following surgery. The evaluated tracheal dimensions included the smallest cross-sectional area of the trachea (SCAT), tracheal narrowing, and tracheal deviation...... with surgical removal of median 46 mL (range, 5-642 mL) (pdeviation were diminished by median 26% (ES=0.67), and 33% (ES=0.73), respectively, while SCAT increased by 17% (ES=0.61). Correspondingly, each 10% decrease in goiter volume resulted...

  13. Development of a 3D bellows tracheal graft: mechanical behavior analysis, fabrication and an in vivo feasibility study

    International Nuclear Information System (INIS)

    Park, Jeong Hun; Jung, Jin Woo; Lee, Jung-Seob; Cho, Dong-Woo; Kang, Hyun-Wook; Joo, Young Hoon

    2012-01-01

    Artificial tracheal grafts should have not only enough compressive strength to maintain an open tracheal lumen, but also sufficient flexibility for stable mechanical behavior, similar to the native trachea at the implant site. In this study, we developed a new 3D artificial tracheal graft using a bellows design for considering its mechanical behavior. To investigate the mechanical behavior of the bellows structure, finite element method (FEM) analysis in terms of longitudinal tension/compression, bending and radial compression was conducted. The bellows structure was then compared with the cylinder structure generally used for artificial tracheal grafts. The FEM analysis showed that the bellows had outstanding flexibility in longitudinal tension/compression and bending. Moreover, the bellows kept the lumen open without severe luminal deformation in comparison with the cylinder structure. A three-dimensional artificial tracheal graft with a bellows design was fabricated using indirect solid freeform fabrication technology, and the actual mechanical test was conducted to investigate the actual mechanical behavior of the bellows graft. The fabricated bellows graft was then applied to segmental tracheal reconstruction in a rabbit model to assess its applicability. The bellows graft was completely incorporated into newly regenerated connective tissue and no obstruction at the implanted site was observed for up to 8 weeks after implantation. The data suggested that the developed bellows tracheal graft could be a promising alternative for tracheal reconstruction. (paper)

  14. Percutaneous dilatational tracheostomy using the ETView Tracheoscopic Ventilation Tube®: a teaching course in a pig model.

    Science.gov (United States)

    Fiorelli, Alfonso; Ferraro, Fausto; Frongillo, Elisabetta; Fusco, Pierluigi; Pierdiluca, Matteo; Nagar, Francesca; Iuorio, Angela; Santini, Mario

    2017-10-01

    We planned a training course for trainees of different specialties with the aim of teaching the skills of a new procedure for performing percutaneous dilatational tracheostomy (PDT) with an ETView tracheoscopic ventilation tube instead of standard bronchoscopy in an ex vivo pig model. The endotracheal tube, with a camera-embedded tip, was used as an alternative to standard bronchoscopy for visualization of patient airways. The procedure was performed on a home-made animal model. The participants were asked to perform PDT in three different sessions to improve their dexterity. The primary endpoint was the reduction of complications seen during the different sessions of the training course. The secondary endpoint was the satisfaction of the participants as assessed by an anonymous survey. Thirty-seven residents in anesthesiology and 7 in thoracic surgery in the first 2 years of their training and without any confidence with percutaneous tracheostomy participated in the study. Tracheal cuff lesions and impalement of the tracheal tube were the most observed complications, and were concentrated in the early sessions. A significant reduction in complications and operative time was seen during the ongoing sessions of the course. No lesions of the posterior tracheal wall and only a ring fracture occurred during the last session of the course. All participants were satisfied with the course. Our course seems to confer the technical skills to perform percutaneous tracheostomy to trainees and instill confidence with the procedure. However, the experience acquired on a training course should be evaluated in clinical practice.

  15. Bender/Coiler for Tubing

    Science.gov (United States)

    Stoltzfus, J. M.

    1983-01-01

    Easy-to-use tool makes coils of tubing. Tubing to be bend clamped with stop post. Die positioned snugly against tubing. Operator turns handle to slide die along tubing, pushing tubing into spiral groove on mandrel.

  16. Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Adam N.; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; McKinstry, Robert C. [Barnes Jewish Hospital, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, St. Louis, MO (United States); Vyhmeister, Ross [Washington University School of Medicine, St. Louis, MO (United States); Ramirez-Giraldo, Juan Carlos [Siemens Healthcare, Malvern, PA (United States)

    2015-03-17

    Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality. (orig.)

  17. Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT.

    Science.gov (United States)

    Wallace, Adam N; Vyhmeister, Ross; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; Ramirez-Giraldo, Juan Carlos; McKinstry, Robert C

    2015-06-01

    Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.

  18. Robust self-triggered model predictive control for constrained discrete-time LTI systems based on homothetic tubes

    NARCIS (Netherlands)

    Aydiner, E.; Brunner, F.D.; Heemels, W.P.M.H.; Allgower, F.

    2015-01-01

    In this paper we present a robust self-triggered model predictive control (MPC) scheme for discrete-time linear time-invariant systems subject to input and state constraints and additive disturbances. In self-triggered model predictive control, at every sampling instant an optimization problem based

  19. Is intrathoracic tracheal collapsibility correlated to clinical phenotypes and sex in patients with COPD?

    Directory of Open Access Journals (Sweden)

    Camiciottoli G

    2015-04-01

    Full Text Available Gianna Camiciottoli,1 Stefano Diciotti,2 Francesca Bigazzi,1 Simone Lombardo,3 Maurizio Bartolucci,4 Matteo Paoletti,1 Mario Mascalchi,3 Massimo Pistolesi1 1Section of Respiratory Medicine, Department of Clinical and Experimental Medicine, University of Florence, Florence, Italy; 2Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi,” University of Bologna, Cesena, Italy; 3Radiodiagnostic Section, Department of Clinical and Experimental Biomedical Sciences, University of Florence, Florence, Italy; 4Department of Diagnostic Imaging, Careggi University Hospital, Florence, Italy Abstract: A substantial proportion of patients with chronic obstructive pulmonary disease (COPD develops various degree of intrathoracic tracheal collapsibility. We studied whether the magnitude of intrathoracic tracheal collapsibility could be different across clinical phenotypes and sex in COPD. Intrathoracic tracheal collapsibility measured at paired inspiratory–expiratory low dose computed tomography (CT and its correlation with clinical, functional, and CT-densitometric data were investigated in 69 patients with COPD according to their predominant conductive airway or emphysema phenotypes and according to sex. Intrathoracic tracheal collapsibility was higher in patients with predominant conductive airway disease (n=28 and in females (n=27. Women with a predominant conductive airway phenotype (n=10 showed a significantly greater degree of collapsibility than women with predominant emphysema (28.9%±4% versus 11.6%±2%; P<0.001. Intrathoracic tracheal collapsibility was directly correlated with inspiratory–expiratory volume variation at CT and with forced expiratory volume (1 second, and inversely correlated with reduced CT lung density and functional residual capacity. Intrathoracic tracheal collapsibility was not correlated with cough and wheezing; however, intrathoracic tracheal collapsibility and clinical phenotypes of COPD

  20. Bradykinin B2 receptor-mediated phosphoinositide hydrolysis in bovine cultured tracheal smooth muscle cells.

    OpenAIRE

    Marsh, K. A.; Hill, S. J.

    1992-01-01

    1. Bovine tracheal smooth muscle cells were established in culture to study agonist-induced phosphoinositide (PI) hydrolysis in this tissue. 2. Bradykinin (0.1 nM-10 microM) evoked a concentration-dependent increase (log EC50 (M) = -9.4 +/- 0.2; n = 8) in the accumulation of total [3H]-inositol phosphates in cultured tracheal smooth muscle cells whereas the selective B1 receptor agonist des-Arg9-bradykinin (10 microM) was significantly less effective (16% of bradykinin maximal response; relat...

  1. A retropharyngeal-mediastinal hematoma with supraglottic and tracheal obstruction: The role of multidisciplinary airway management

    Directory of Open Access Journals (Sweden)

    Birkholz Torsten

    2010-01-01

    Full Text Available A 77-year-old man suffered hypoxemic cardiac arrest by supraglottic and tracheal airway obstruction in the emergency department. A previously unknown cervical fracture had caused a traumatic retropharyngeal-mediastinal hematoma. A lifesaving surgical emergency tracheostomy succeeded. Supraglottic and tracheal obstruction by a retropharyngeal-mediastinal hematoma with successful resuscitation via emergency tracheostomy after hypoxemic cardiac arrest has never been reported in a context of trauma. This clinically demanding case outlines the need for multidisciplinary airway management systems with continuous training and well-implemented guidelines. Only multidisciplinary staff preparedness and readily available equipments for the unanticipated difficult airway solved the catastrophic clinical situation.

  2. Endobronchial angiofibroma in the aberrant tracheal bronchus presenting as spontaneous pneumomediastinum.

    Science.gov (United States)

    Kim, Kyung Soo; Moon, Young Kyu; Jeon, Hyun Woo; Park, Chan Beom; Ahn, Myeong Im; Lee, Kyo Young; Park, Jae Kil

    2015-07-22

    Spontaneous pneumomediastinum is a self-limiting benign disease but abnormal bronchial lesions can be rarely found incidentally, and in selected cases will require surgical resection. A 38-year-old man presented with a spontaneous pneumomediastinum. Chest computed tomography revealed an incidental linear endobronchial tumour in the aberrant tracheal bronchus. The tumour was removed surgically and diagnosed with a rare benign tumour of endobronchial angiofibroma. We report a rare case of endobronchial angiofibroma in the aberrant tracheal bronchus which was detected during the evaluation of a spontaneous pneumomediastinum.

  3. Influence of paclitaxel-eluting expandable metallic stent on tissue hyperplasia: an experimental study in a canine tracheal model

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Kim, Jung Sun; Kim, Tae Hyung; Kim, Eun Young; Choi, Won Chan; Woo, Chul Woong; Di, Zhenhai; Song, Ho Young; Yuk, Soon Hong; Lee, Yong Seok

    2005-01-01

    To evaluate the efficacy of a paclitaxel-eluting expandable metallic stent in reducing tissue hyperplasia following stent placement in a canine tracheal model. Nine paclitaxel-eluting stents (drug stent, DS) consisting of a proximal bare part and a distal polyurethane-covered part were placed in the trachea of nine dogs and nine control stents (control stent, CS) were placed in the other nine dogs. The dogs were scheduled to be sacrificed 12 weeks after stent placement. Gross and histological factors, such as epithelial erosion/ulcer, granulation tissue thickness and inflammatory cell infiltration were evaluated after each dog was sacrificed. There were no procedure-related complications or malpositioning of any of the stents. One CS migrated less than eight weeks following stent placement. Four dogs (one DS and three CS dogs) died between three and five weeks following stent placement. Therefore, pathologic specimens were obtained from eight DS and five CS dogs. Epithelial erosion/ulcer or inflammatory cell infiltration was slightly more prominent in the DS cases than in the CS cases, in both the bare part and the covered part. However, the data was not statistically significant. Granulation tissue thickness was lower in the DS cases than in the CS cases in both the bare part (mean, 3.63-mm vs. 4.37-mm) and the covered part (mean, 1.75-mm vs. 2,78 mm), but the data was also statistically insignificant. Although the data was not statistically significant, placement of paclitaxel-eluting expandable metallic stent demonstrates a tendency toward a decrease in granulation tissue thickness in canine tracheal models

  4. Influence of paclitaxel-eluting expandable metallic stent on tissue hyperplasia: an experimental study in a canine tracheal model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Kim, Jung Sun; Kim, Tae Hyung; Kim, Eun Young; Choi, Won Chan; Woo, Chul Woong; Di, Zhenhai; Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yuk, Soon Hong [Hannam University, College of Engineering, Daejeon (Korea, Republic of); Lee, Yong Seok [Wonkwang University College of Medicine, Iksan (Korea, Republic of)

    2005-07-15

    To evaluate the efficacy of a paclitaxel-eluting expandable metallic stent in reducing tissue hyperplasia following stent placement in a canine tracheal model. Nine paclitaxel-eluting stents (drug stent, DS) consisting of a proximal bare part and a distal polyurethane-covered part were placed in the trachea of nine dogs and nine control stents (control stent, CS) were placed in the other nine dogs. The dogs were scheduled to be sacrificed 12 weeks after stent placement. Gross and histological factors, such as epithelial erosion/ulcer, granulation tissue thickness and inflammatory cell infiltration were evaluated after each dog was sacrificed. There were no procedure-related complications or malpositioning of any of the stents. One CS migrated less than eight weeks following stent placement. Four dogs (one DS and three CS dogs) died between three and five weeks following stent placement. Therefore, pathologic specimens were obtained from eight DS and five CS dogs. Epithelial erosion/ulcer or inflammatory cell infiltration was slightly more prominent in the DS cases than in the CS cases, in both the bare part and the covered part. However, the data was not statistically significant. Granulation tissue thickness was lower in the DS cases than in the CS cases in both the bare part (mean, 3.63-mm vs. 4.37-mm) and the covered part (mean, 1.75-mm vs. 2,78 mm), but the data was also statistically insignificant. Although the data was not statistically significant, placement of paclitaxel-eluting expandable metallic stent demonstrates a tendency toward a decrease in granulation tissue thickness in canine tracheal models.

  5. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahrar, Judy U., E-mail: judy.ahrar@mdanderson.org; Gupta, Sanjay [The University of Texas M.D. Anderson Cancer Center, Department of Interventional Radiology (United States); Ensor, Joe E. [Houston Methodist Research Institute, The Houston Methodist Cancer Center (United States); Mahvash, Armeen; Sabir, Sharjeel H.; Steele, Joseph R.; McRae, Stephen E.; Avritscher, Rony; Huang, Steven Y.; Odisio, Bruno C.; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J.; Tam, Alda L. [The University of Texas M.D. Anderson Cancer Center, Department of Interventional Radiology (United States)

    2017-02-15

    PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  6. Use of a Nitinol Wire Stent for Management of Severe Tracheal Stenosis in an Eclectus Parrot (Eclectus roratus).

    Science.gov (United States)

    Mejia-Fava, Johanna; Holmes, Shannon P; Radlinsky, MaryAnn; Johnson, Dan; Ellis, Angela E; Mayer, Jörg; Schnellbacher, Rodney; Divers, Stephen J

    2015-09-01

    A 25-year-old, female eclectus parrot (Eclectus roratus) presented for dyspnea 3 weeks after anesthesia and surgery for egg yolk coelomitis. Radiography, computed tomography, and tracheoscopy revealed multiple tracheal strictures spanning a length of 2.6 cm in the mid to distal trachea. Histopathologic examination revealed mild fibrosis, inflammation, and hyperplasia consistent with acquired tracheal strictures. Tracheal resection was not considered possible because of the length of the affected trachea. The strictures were resected endoscopically, and repeated balloon dilation under fluoroscopic guidance over the course of 10 months resulted in immediate but unsustained improvement. Computed tomography was used to measure the stenotic area. A 4 × 36-mm, custom-made, nitinol wire stent was inserted into the trachea under fluoroscopic guidance. After stent placement, intermittent episodes of mild to moderate dyspnea continued, and these responded to nebulization with a combination of saline, acetylcysteine, and dexamethasone. Multiple attempts to wean the patient off nebulization therapy and to switch to a corticosteroid-free combination were unsuccessful. The parrot eventually developed complications, was euthanatized, and necropsy was performed. Histologically, the tracheal mucosa had widespread erosion to ulceration, with accumulation of intraluminal exudate and bacteria, severe degeneration of skeletal muscle and tracheal rings, prominent fibrosis, and mild to moderate, submucosal inflammation. Clinicopathologic findings in this case suggested tracheomalacia, which has not been previously described in birds. Custom-made tracheal stents can be used for severe tracheal stenosis in birds when tracheal resection and anastomosis is not possible. Complications of tracheal stent placement in birds may include tracheitis and tracheomalacia. To our knowledge, this is the first report of tracheal stent placement in an avian species.

  7. A Peer-Reviewed Instructional Video is as Effective as a Standard Recorded Didactic Lecture in Medical Trainees Performing Chest Tube Insertion: A Randomized Control Trial.

    Science.gov (United States)

    Saun, Tomas J; Odorizzi, Scott; Yeung, Celine; Johnson, Marjorie; Bandiera, Glen; Dev, Shelly P

    Online medical education resources are becoming an increasingly used modality and many studies have demonstrated their efficacy in procedural instruction. This study sought to determine whether a standardized online procedural video is as effective as a standard recorded didactic teaching session for chest tube insertion. A randomized control trial was conducted. Participants were taught how to insert a chest tube with either a recorded didactic teaching session, or a New England Journal of Medicine (NEJM) video. Participants filled out a questionnaire before and after performing the procedure on a cadaver, which was filmed and assessed by 2 blinded evaluators using a standardized tool. Western University, London, Ontario. Level of clinical care: institutional. A total of 30 fourth-year medical students from 2 graduating classes at the Schulich School of Medicine & Dentistry were screened for eligibility. Two students did not complete the study and were excluded. There were 13 students in the NEJM group, and 15 students in the didactic group. The NEJM group׳s average score was 45.2% (±9.56) on the prequestionnaire, 67.7% (±12.9) for the procedure, and 60.1% (±7.65) on the postquestionnaire. The didactic group׳s average score was 42.8% (±10.9) on the prequestionnaire, 73.7% (±9.90) for the procedure, and 46.5% (±7.46) on the postquestionnaire. There was no difference between the groups on the prequestionnaire (Δ + 2.4%; 95% CI: -5.16 to 9.99), or the procedure (Δ -6.0%; 95% CI: -14.6 to 2.65). The NEJM group had better scores on the postquestionnaire (Δ + 11.15%; 95% CI: 3.74-18.6). The NEJM video was as effective as video-recorded didactic training for teaching the knowledge and technical skills essential for chest tube insertion. Participants expressed high satisfaction with this modality. It may prove to be a helpful adjunct to standard instruction on the topic. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc

  8. Control of adverse effects of explosive blasting in mines by using shock tube (non-electric) initiation systems and its future challenges

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, P.D. [Maharashtra Explosives Ltd., Nagpur (India)

    2000-04-01

    Every kind of blasting in mines produces some adverse effects on environment, such as ground vibration, noise, fly rock etc. Presently, for restricting these adverse effects, use of shock tube (non-electric) initiation systems are gaining momentum. There are some inherent shortcomings of this initiation system regarding chances of misfires. This paper discusses the various adverse effects of blasting, advantages of shock tube initiation system and the shortcomings of shock tube initiation system regarding chances of misfire and how misfire arises out of failure of shock tube initiation system is different and more dangerous than the misfire occurring due to failure of conventional system (with detonating fuse and cord relays). 1 tab.

  9. Evaluating remote control and robotics actions in NPPs in an ALARA perspective: lessons from the evolution of steam generator tube plugging technique in France

    International Nuclear Information System (INIS)

    Lefaure, C.; Lochard, J.; Blain, A.

    1989-01-01

    Introducing remote tooling and robotics in NPPs raises many questions. Is it better to develop specific robotic tools for each type of operation, or to conceive more generic multipurpose tool carriers. Does the introduction of remote control and robotics always reduce human involvement and collective doses. What are the impacts on individual doses distribution for the most exposed operators. Under what conditions is robotics justified from an economical point of view. Even if robotics and remote tooling actions can reduce significantly individual and collective exposures, because of their high costs of development, they will be adopted only if simultaneously the potential for operational cost savings is also clearly demonstrated. Integrating operational cost savings in the cost evaluation of the ALARA procedure is important to compare and select among different robotics and remote control actions. This paper presents how to evaluate in a systematic way dose reductions, operational costs savings as well as the conditions under which robotics and remote control actions can effectively improve occupational radiation protection in NPPs. The demonstration is based on an analysis of the evolution of the steam generator tube plugging technique developed in French PWRs

  10. Association of neural tube defects in children of mothers with MTHFR 677TT genotype and abnormal carbohydrate metabolism risk: a case-control study.

    Science.gov (United States)

    Cadenas-Benitez, N M; Yanes-Sosa, F; Gonzalez-Meneses, A; Cerrillos, L; Acosta, D; Praena-Fernandez, J M; Neth, O; Gomez de Terreros, I; Ybot-González, P

    2014-03-26

    Abnormalities in maternal folate and carbohydrate metabolism have both been shown to induce neural tube defects (NTD) in humans and animal models. However, the relationship between these two factors in the development of NTDs remains unclear. Data from mothers of children with spina bifida seen at the Unidad de Espina Bífida del Hospital Infantil Virgen del Rocío (case group) were compared to mothers of healthy children with no NTD (control group) who were randomly selected from patients seen at the outpatient ward in the same hospital. There were 25 individuals in the case group and 41 in the control group. Analysis of genotypes for the methylenetetrahydrofolate reductase (MTHFR) 677CT polymorphism in women with or without risk factors for abnormal carbohydrate metabolism revealed that mothers who were homozygous for the MTHFR 677TT polymorphism and at risk of abnormal carbohydrate metabolism were more likely to have offspring with spina bifida and high levels of homocysteine, compared to the control group. The increased incidence of NTDs in mothers homozygous for the MTHFR 677TT polymorphism and at risk of abnormal carbohydrate metabolism stresses the need for careful metabolic screening in pregnant women, and, if necessary, determination of the MTHFR 677CT genotype in those mothers at risk of developing abnormal carbohydrate metabolism.

  11. Extensive feedwater quality control and monitoring concept for preventing chemistry-related failures of boiler tubes in a subcritical thermal power plant

    International Nuclear Information System (INIS)

    Vidojkovic, Sonja; Onjia, Antonije; Matovic, Branko; Grahovac, Nebojsa; Maksimovic, Vesna; Nastasovic, Aleksandra

    2013-01-01

    Prevention and minimizing corrosion processes on steam generating equipment is highly important in the thermal power industry. The maintenance of feedwater quality at a level corresponding to the standards of technological designing, followed by timely respond to the fluctuation of measured parameters, has a decisive role in corrosion prevention. In this study, the comprehensive chemical control of feedwater quality in 210 MW Thermal Power Plant (TPP) was carried out in order to evaluate its potentiality to assure reliable function of the boiler and discover possible irregularity that might be responsible for frequent boiler tube failures. Sensitive on-line and off-line analytical instruments were used for measuring key and diagnostic parameters considered to be crucial for boiler safety and performances. Obtained results provided evidences for exceeded levels of oxygen, silica, sodium, chloride, sulfate, copper, and conductivity what distinctly demonstrated necessity of feedwater control improvement. Consequently, more effective feedwater quality monitoring concept was recommended. In this paper, the explanation of presumable root causes of corrosive contaminants was given including basic directions for their maintenance in proscribed limits. -- Highlights: • Feedwater quality monitoring practice in a thermal power plant has been evaluated. • The more efficient feedwater quality control have been applied. • Analysis of feedwater quality parameters has been performed. • Exceeded levels of corrosive contaminants were found. • Recommendations for their maintenance at proscribed values were given

  12. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.

    Science.gov (United States)

    Ahrar, Judy U; Gupta, Sanjay; Ensor, Joe E; Mahvash, Armeen; Sabir, Sharjeel H; Steele, Joseph R; McRae, Stephen E; Avritscher, Rony; Huang, Steven Y; Odisio, Bruno C; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J; Tam, Alda L

    2017-02-01

    To evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy. In this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02. Before matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p 30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates. The self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  13. Avian metapneumovirus infection of chicken and turkey tracheal organ cultures: comparison of virus-host interactions.

    Science.gov (United States)

    Hartmann, Sandra; Sid, Hicham; Rautenschlein, Silke

    2015-01-01

    Avian metapneumovirus (aMPV) is a pathogen with worldwide distribution, which can cause high economic losses in infected poultry. aMPV mainly causes infection of the upper respiratory tract in both chickens and turkeys, although turkeys seem to be more susceptible. Little is known about virus-host interactions at epithelial surfaces after aMPV infection. Tracheal organ cultures (TOC) are a suitable model to investigate virus-host interaction in the respiratory epithelium. Therefore, we investigated virus replication rates and lesion development in chicken and turkey TOC after infection with a virulent aMPV subtype A strain. Aspects of the innate immune response, such as interferon-α and inducible nitric oxide synthase mRNA expression, as well as virus-induced apoptosis were determined. The aMPV-replication rate was higher in turkey (TTOC) compared to chicken TOC (CTOC) (P < 0.05), providing circumstantial evidence that indeed turkeys may be more susceptible. The interferon-α response was down-regulated from 2 to 144 hours post infection in both species compared to virus-free controls (P < 0.05); this was more significant for CTOC than TTOC. Inducible nitric oxide synthase expression was significantly up-regulated in aMPV-A-infected TTOC and CTOC compared to virus-free controls (P < 0.05). However, the results suggest that NO may play a different role in aMPV pathogenesis between turkeys and chickens as indicated by differences in apoptosis rate and lesion development between species. Overall, our study reveals differences in innate immune response regulation and therefore may explain differences in aMPV - A replication rates between infected TTOC and CTOC, which subsequently lead to more severe clinical signs and a higher rate of secondary infections in turkeys.

  14. In vitro evaluation of the method effectiveness to limit inflation pressure cuffs of endotracheal tubes

    Directory of Open Access Journals (Sweden)

    Rafael de Macedo Coelho

    2016-04-01

    Full Text Available ABSTRACT BACKGROUND AND OBJECTIVE: Cuffs of tracheal tubes protect the lower airway from aspiration of gastric contents and facilitate ventilation, but may cause many complications, especially when the cuff pressure exceeds 30 cm H2O. This occurs in over 30% of conventional insufflations, so it is recommended to limit this pressure. In this study we evaluated the in vitro effectiveness of a method of limiting the cuff pressure to a range between 20 and 30 cm H2O. METHOD: Using an adapter to connect the tested tube to the anesthesia machine, the relief valve was regulated to 30 cm H2O, inflating the cuff by operating the rapid flow of oxygen button. There were 33 trials for each tube of three manufacturers, of five sizes (6.5-8.5, using three times inflation (10, 15 and 20 s, totaling 1485 tests. After inflation, the pressure obtained was measured with a manometer. Pressure >30 cm H2O or <20 cm H2O were considered failures. RESULTS: There were eight failures (0.5%, 95% CI: 0.1-0.9%, with all by pressures <20 cm H2O and after 10 s inflation (1.6%, 95% CI: 0 5-2.7%. One failure occurred with a 6.5 tube (0.3%, 95% CI: -0.3 to 0.9%, six with 7.0 tubes (2%, 95% CI: 0.4-3.6%, and one with a 7.5 tube (0.3%, 95% CI: -0.3 to 0.9%. CONCLUSION: This method was effective for inflating tracheal tube cuffs of different sizes and manufacturers, limiting its pressure to a range between 20 and 30 cm H2O, with a success rate of 99.5% (95% CI: 99.1-99.9%.

  15. Effects of oral methylprednisolone and inhaled salbutamol in the decrease of wheezing in patients with asthma after tracheal intubation

    Directory of Open Access Journals (Sweden)

    2008-08-01

    Full Text Available Background: Airway instrumentation in patients with bronchial hyperreactivity, may evoke life-threatening asthma attack and a good strategy for the prevention of bronchospasm"nhas not been defined. In a randomized, prospective, placebo-controlled study, it was determined whether prophylaxis with either inhaled salbutamol-or combined inhaled salbutamol and oral methylprednisolone improves lung functions and prevents wheezing after intubation. Methods: Thirty one patients with partially reversible airway obstruction (airway resistance> 180%, forced expiratory volume in 1 second [FEV1] < 70% of predicted value, and FEV1 increase> 12% after two puffs of salbutamol were randomized to receive daily either 3-2 puffs (0.2 mg of salbutamol (n =16 or 3-2 puffs (0.2 mg of salbutamol and 40 mg of methylprednisolone (n = 15 orally for 5 days. In all patients lung function was evaluated daily and wheezing changes was assessed before and 5 minutes after tracheal intubation. Results: Both salbutamol and combined inhaled salbutamol and oral methylprednisolone treatment significantly improved airway resistance and FEV1 to a steady state, with no difference between groups. When a single-dose of salbutamol pre-induction or prolonged salbutamol treatment was employed, most patients (8 of 10 and 7 of 9 experienced wheezing after intubation. In contrast, only one patient of those who received both salbutamol and methylprednisolone experienced wheezing (P = 0.0058. Conclusions: Pretreatment with either salbutamol or combined inhaled salbutamol and oral methylprednisolone significantly improves lung function and decreases the incidence of wheezing after tracheal intubation. Methylprednisolone decreases incidence of wheezing more than salbutamol. Therefore, in patients with bronchial hyper reactivity, preoperative treatment with both methylprednisolone and salbutamol minimizes intubation-evoked broncho-constriction.

  16. The effects of ventilation tubes versus no ventilation tubes for recurrent acute otitis media or chronic otitis media with effusion in 9 to 36 month old Greenlandic children, the SIUTIT trial: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Demant, Malene Nøhr; Jensen, Ramon Gordon; Jakobsen, Janus Christian; Gluud, Christian; Homøe, Preben

    2017-01-19

    The prevalence of otitis media in Greenlandic children is one of the highest in the world. International studies have shown that otitis-prone children may benefit from tubulation of the tympanic membrane. However, it is unknown whether these results can be applied to Greenlandic children and trials on the effects of ventilation tubes in high-risk populations have, to our knowledge, never been conducted. The trial is an investigator-initiated, multicentre, randomized, blinded superiority trial of bilateral ventilation tube insertion versus treatment as usual (no tube) in Greenlandic children aged 9-36 months with chronic otitis media with effusion or recurrent acute otitis media. With randomization stratified by otitis media subtype and trial site, a type 1 error of 5% and a power of 80%, a total of 230 participants are needed to detect a decrease of two visits to a health clinic during 2 years, which is considered the minimal clinical relevant difference. The primary outcome measure will be assessed blindly by investigating medical records. Secondary outcome measures are number of episodes of acute otitis media, quality of life, number of episodes of antibiotics administration and proportion of children with tympanic membrane perforations. This trial will provide evidence-based knowledge of the effects of ventilation tubes in children with middle ear infections from the high-risk Greenlandic population. Furthermore, this trial will improve the understanding of conducting randomized clinical trials in remote areas, where management of logistical aspects is particularly challenging. ClinicalTrials.gov, NCT02490332 . Registered on 14 February 2016.

  17. Groningen Dilatation Tracheoscope in Treatment of Moderate Subglottic and Tracheal Stenosis

    NARCIS (Netherlands)

    Halmos, Gyorgy; van der Laan, Bernard F. A. M.; Dikkers, Frederik G.

    Objectives: We describe our experience with the Groningen Dilatation Tracheoscope (Karl Storz GmbH & Co, Tuttlingen, Germany) in treating benign subglottic and tracheal stenosis. Methods: We performed a retrospective survey from a medical record analysis of 26 patients with different origins of

  18. Expandable metal stents for tracheal obstruction: permanent or temporary? A cautionary tale.

    OpenAIRE

    Hind, C R; Donnelly, R J

    1992-01-01

    An expandable metal stent inserted via a long term tracheostomy successfully relieved life threatening respiratory obstruction due to benign tracheal stenosis. Later the patient's tracheostomy suction catheter became stuck on the stent and dislodged it. The stent was removed electively, without damaging the trachea, with a rigid biopsy forceps.

  19. Awake fiberoptic or awake video laryngoscopic tracheal intubation in patients with anticipated difficult airway management

    DEFF Research Database (Denmark)

    Rosenstock, Charlotte Vallentin; Thøgersen, Bente; Afshari, Arash

    2012-01-01

    Awake flexible fiberoptic intubation (FFI) is the gold standard for management of anticipated difficult tracheal intubation. The purpose of this study was to compare awake FFI to awake McGrath® video laryngoscope, (MVL), (Aircraft Medical, Edinburgh, Scotland, United Kingdom) intubation in patients...... with an anticipated difficult intubation. The authors examined the hypothesis that MVL intubation would be faster than FFI....

  20. Equine tracheal epithelial membrane strips - An alternate method for examining epithelial cell arachidonic acid metabolism

    International Nuclear Information System (INIS)

    Gray, P.R.; Derksen, F.J.; Robinson, N.E.; Peter-Golden, M.L.

    1990-01-01

    Arachidonic acid metabolism by tracheal epithelium can be studied using enzymatically dispersed cell suspensions or cell cultures. Both techniques require considerable tissue disruption and manipulation and may not accurately represent in vivo activity. The authors have developed an alternate method for obtaining strips of equine tracheal epithelium without enzymatic digestion. In the horse, a prominent elastic lamina supports the tracheal epithelium. By physical splitting this lamina, they obtained strips (≤12 x 1.5 cm) of pseudostratified columnar epithelium attached to a layer of elastic tissue 30-100 μm thick. Epithelial strips (1.2 x 0.5 cm) were attached to plexiglass rods and incubated with [ 3 H]arachidonic acid in M199 medium (0.5 μCi/ml) for 24 hours at 37C. The strips incorporated 36±4% (mean ± SEM) of the total radioactivity and released 8.0±1.2% of incorporated radioactivity when stimulated by 5.0 μM calcium ionophore A23187. The extracted supernatant was processed using HPLC, resulting in peaks of radioactivity that co-eluted with authentic PGE 2 , PGF 2 α, and 12-HETE standards. The greatest activity corresponded to the PGE 2 and PGF 2 α standards, which is a similar pattern to that reported for cultured human tracheal epithelium

  1. High frequency components of tracheal sound are emphasized during prolonged flow limitation

    International Nuclear Information System (INIS)

    Tenhunen, M; Huupponen, E; Saastamoinen, A; Kulkas, A; Himanen, S-L; Rauhala, E

    2009-01-01

    A nasal pressure transducer, which is used to study nocturnal airflow, also provides information about the inspiratory flow waveform. A round flow shape is presented during normal breathing. A flattened, non-round shape is found during hypopneas and it can also appear in prolonged episodes. The significance of this prolonged flow limitation is still not established. A tracheal sound spectrum has been analyzed further in order to achieve additional information about breathing during sleep. Increased sound frequencies over 500 Hz have been connected to obstruction of the upper airway. The aim of the present study was to examine the tracheal sound signal content of prolonged flow limitation and to find out whether prolonged flow limitation would consist of abundant high frequency activity. Sleep recordings of 36 consecutive patients were examined. The tracheal sound spectral analysis was performed on 10 min episodes of prolonged flow limitation, normal breathing and periodic apnea-hypopnea breathing. The highest total spectral amplitude, implicating loudest sounds, occurred during flow-limited breathing which also presented loudest sounds in all frequency bands above 100 Hz. In addition, the tracheal sound signal during flow-limited breathing constituted proportionally more high frequency activities compared to normal breathing and even periodic apnea-hypopnea breathing

  2. Association between pathogens from tracheal aspirate and oral biofilm of patients on mechanical ventilation.

    Science.gov (United States)

    Souza, Luana Carneiro Diniz; Mota, Vanise Barros Rodrigues da; Carvalho, Alícia Valéria Dos Santos Zaranza de; Corrêa, Rita da Graça Carvalhal Frazão; Libério, Silvana Amado; Lopes, Fernanda Ferreira

    2017-06-05

    The aim of this study was to detect possible associations between respiratory pathogens from tracheal aspirate and oral biofilm samples in intubated patients in an intensive care unit (ICU), and to identify the most common respiratory pathogens in oral biofilm, particularly in patients that developed ventilator-associated pneumonia (VAP). Two oral biofilm samples were collected from the tongue of intubated patients (at admission and after 48 hours) and analyzed by culture with the Antibiotic Sensitivity Test. The results from the tongue biofilm samples were compared with the tracheal secretions samples. A total of 59.37% of patients exhibited the same species of pathogens in their tracheal aspirate and oral biofilm, of which 8 (42.1%) developed VAP, 10 (52.63%) did not develop pneumonia and one (5.26%) had aspiration pneumonia. There was a statistically significant association between presence of microorganisms in the tracheal and mouth samples for the following pathogens: Klebsiella pneumoniae, Candida albicans, Pseudomonas aeruginosa, Enterobacter gergoviae, Streptococcus spp and Serratia marcescens (p aspirates of intubated patients can be detected in their oral cavity, especially in those who developed VAP or aspiration pneumonia. Thus, the results indicate that an improved oral care in these patients could decrease ICU pneumonia rates.

  3. Using tracheal segments for replacement of cervical oesophagus: an experimental study.

    Science.gov (United States)

    Abbasidezfouli, Azizollah; Sharifi, Davood; Sasani, Farhang; Ansari, Damoon; Abarkar, Mohammad; Rahmanijoo, Nasrin; Abbasidezfouli, Golbahar; Sheikhy, Kambiz

    2012-03-01

    Segmental resection and anastomosis of oesophageal lesions are not performed as a routine clinical practice because of complications and associated problems, whereas tracheal resection and anastomosis are a routine clinical practice. In this experimental study, we resected a segment of cervical oesophagus and replaced it with a tracheal segment. In eight dogs (mixed races), weighing 20-30 kg, ageing 1-2 years, under general anaesthesia, through a cervical incision, 5 cm of cervical trachea was separated while preserving its attachments to surrounding fibroareolar tissues. Afterwards, 5 cm of the oesophagus was resected and replaced with a prepared segment of the trachea. Oral liquids were started at the first post-operative day; the animals were kept for 2 months and then euthanized. Quality of swallowing and voice were evaluated. After an autopsy, anastomoses were examined grossly and histopathologically. No complications occurred during surgery. Swallowing function and voice were normal in all eight dogs after the operation. No sign of aspiration was seen in clinical and radiographic examinations after starting oral diet. In autopsy examination, anastomoses were patent without narrowing or abnormal mucosal changes. Remarkable histopathological findings in replaced tracheal segments were squamous metaplasia, atrophy and degeneration of mucosal glands and degeneration of cartilages. Replacement of a segment of the oesophagus with an autogenous tracheal segment is a practical procedure with low complications and can probably be used for the treatment of cervical oesophageal lesions in human beings.

  4. Relaxing action of adrenergic β2-agonists on guinea-pig skinned tracheal muscle

    Directory of Open Access Journals (Sweden)

    Kayo Nemoto

    1999-01-01

    Full Text Available Although adrenergic β2-agonist-induced smooth muscle relaxation has been attributed to increased intracellular cyclic AMP (cAMP, a relaxation response has been observed at low β2-agonist concentrations that do not cause increased cAMP To elucidate the mechanism of tracheal muscle relaxation induced by low concentrations of β2-agonists, we used a guinea-pig skinned tracheal smooth muscle preparation to examine the effects on the contractile protein system. The isotonic contraction of β-escin-treated skinned tracheal muscle from guinea-pig was measured. When the intracellular Ca2+ concentration was maintained at 1 μmol/L in the presence of guanosine 5′-triphosphate (GTP; 100 μmol/L, neither isoproterenol (10nmol/L nor salbutamol (60 nmol/L affected Ca2+ sensitivity, but a significant decrease in Ca2+ sensitivity was observed in the presence of okadaic acid (1 μmol/L. The decrease in Ca2+ sensitivity was a slow response and was blocked by pretreatment with propranolol (1 μmol/L. Forskolin (1 μmol/L did not affect Ca2+ sensitivity. These results suggest that adrenergic b 2-agonists may activate protein phosphatase through an unknown pathway involving the β2-receptor, which enhances dephosphorylation of the myosin light chain and/or thin filament proteins, resulting in relaxation of the tracheal smooth muscle.

  5. Thyroidectomy improves tracheal anatomy and airflow in patients with nodular goiter. A prospective cohort study

    DEFF Research Database (Denmark)

    Sørensen, Jesper Roed; Lauridsen, Jeppe Killerich; Døssing, Helle

    . Effect sizes (ES) were calculated as mean change divided by standard deviation at baseline. ES of 0.2-0.5 were defined as small, 0.5-0.8 as moderate, and values >0.8 as large.Results: Sixty-five patients completed all examinations. Median goiter volume was 58 mL (range, 14-642 mL) before surgery...... resonance images (MRI) of the neck and respiratory flow-volume curves, including both in- and expiration, were performed prior to and six months following surgery. The evaluated tracheal dimensions included the smallest cross-sectional area of the trachea (SCAT), tracheal narrowing, and tracheal deviation...... with surgical removal of median 43 g (range, 8-607 mL). Six months post-surgery, tracheal narrowing and deviation were diminished by median 26% (ES=0.67), and 33% (ES=0.73), respectively, while SCAT increased by 17% (ES=0.61). Correspondingly, each 10% decrease in goiter volume resulted in an increase of 6...

  6. An approach to tracheostomy in a patient with an expandable metallic tracheal stent.

    Science.gov (United States)

    Madden, Brendan P; Sheth, Abhijat

    2005-09-01

    With increasing use of expandable metallic stents to manage patients with a variety of endobronchial pathologies, some will have a subsequent need for tracheostomy insertion. We describe a successful technique to insert a tracheostomy using rigid and fibre-optic bronchoscopy in a patient who had an 8 cm expandable metallic tracheal stent deployed previously on account of tracheomalacia.

  7. Controlled formation of Ni(DMG)2 microrods/tubes by manipulating the kinetics of chemical reactions and their application in naked-eye sensors.

    Science.gov (United States)

    Qin, Jianli; Wang, Bo; Zhang, Xiujuan; Zhang, Xiaohong

    2012-08-01

    We have demonstrated controlled preparation of Ni(DMG)2 microrods/tubes via chemical reaction method. By manipulating the reaction kinetics via the concentration of reactants, shapes of the resulting microstructures can be easily tuned from microrods to microtubes. Size of the resulting products can also be controlled through changing the reaction temperatures. It was proposed that under high reactants' concentrations, molecules will prefer to grow at corners or edges of nuclei with high free energies, to reduce the total energy in the system, which would lead to partial or complete hollow interiors and eventually resulted in mircotubes. The fact that DMG show high selectivity with Ni2+ and accompanied with obvious color change enable us to fabricate test strip for naked-eye detection of Ni2+. Benefit from the large surface areas of DMG nanoparticles on the test strip, the detection limit is improved by two orders over that of conventional solution method. This strategy is sensitive, simple and easy to handle, thus expected to possess potentials for the practical Ni2+ detection applications.

  8. Tracheal compression due to an elongated aortic arch in patients with congenital heart disease: evaluation using multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Noriko; Hayabuchi, Yasunobu; Inoue, Miki; Sakata, Miho; Nabo, Manal Mohamed Helmy; Nakagawa, Ryuji; Saijo, Takahiko; Kagami, Shoji [University of Tokushima, Department of Pediatrics, Tokushima (Japan)

    2009-10-15

    The airway can become obstructed as a result of compression by an elongated aortic arch. In this study we evaluated tracheal compression using multidetector-row CT in patients with congenital heart disease and an elongated aortic arch. The trachea was measured at the level of the aortic arch in 205 children and young adults and then the severity of tracheal compression was determined by measuring the tracheal diameter ratio (short axis diameter/long axis diameter). Patients were divided as follows: group I (normal aortic arch; n=166), group II (transversely running aortic arch; n=22), and group III (elongated aortic arch; n=17). From the viewpoint of the relationship of the great arteries, group II had D-malposition, and group III had L-malposition. Age, height, weight and body surface area were significantly correlated with the short and long axis diameter in group I. There was a negative correlation between tracheal diameter ratio and the physical size parameters. The tracheal diameter ratio in group III was 0.50{+-}0.13, which was significantly lower than in groups I and II (P<0.01 and 0.05, respectively). Even apparently asymptomatic patients with an elongated aortic arch can have tracheal compression. An elongated aortic arch may be a useful predictor of tracheal compression. (orig.)

  9. An unusual salvage technique for posterior tracheal membranous laceration associated with transhiatal esophagectomy: A transcervical–transsternal approach

    Directory of Open Access Journals (Sweden)

    Seyed Ziaeddin Rasihashemi

    2017-09-01

    Full Text Available Various surgical approaches may be employed for esophageal resection. Major airway injuries due to transhiatal esophagectomy include vertical tears in the membranous trachea. Tracheal injury is an uncommon but potentially fatal complication. This article describes the technique to repair the posterior membranous tracheal tear, extended just over the carina through a transcervical–transsternal approach, thereby avoiding a second thoracotomy. Six patients with posterior membranous tracheal injury underwent this procedure. The laceration ranged from 3 cm to 5 cm in length. Four patients had received neoadjuvant chemoradiation. The management of tracheal laceration added approximately 60 minutes to the total operation time. There was no mortality related to tracheal injury. Patients were followed up for 6 months after surgery, and both posterior tracheal wall and transverse tracheotomy remained intact without stenosis. The transcervical–transsternal approach decreases the need of thoracotomy and its complications in patients with tracheal laceration in any stage, even in cases of an extended tear down to the carina.

  10. Brushless dc motor uses electron beam switching tube as commutator

    Science.gov (United States)

    Studer, P.

    1965-01-01

    Electron beam switching tube eliminates physical contact between rotor and stator in brushless dc motor. The tube and associated circuitry control the output of a dc source to sequentially energize the motor stator windings.

  11. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  12. Pressure tube type reactors

    International Nuclear Information System (INIS)

    Komada, Masaoki.

    1981-01-01

    Purpose: To increase the safety of pressure tube type reactors by providing an additional ECCS system to an ordinary ECCS system and injecting heavy water in the reactor core tank into pressure tubes upon fractures of the tubes. Constitution: Upon fractures of pressure tubes, reduction of the pressure in the fractured tubes to the atmospheric pressure in confirmed and the electromagnetic valve is operated to completely isolate the pressure tubes from the fractured portion. Then, the heavy water in the reactor core tank flows into and spontaneously recycles through the pressure tubes to cool the fuels in the tube to prevent their meltdown. By additionally providing the separate ECCS system to the ordinary ECCS system, fuels can be cooled upon loss of coolant accidents to improve the safety of the reactors. (Moriyama, K.)

  13. Gastrostomy feeding tube - bolus

    Science.gov (United Stat