WorldWideScience

Sample records for contrast enhanced ct

  1. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  2. Contrast enhanced CT of spinal cord angioma

    International Nuclear Information System (INIS)

    Nakamura, Takahiko; Ebitani, Tsutomu; Honma, Takao; Sofue, Muroto; Nakamura, Shigeru

    1982-01-01

    Contrast enhanced CT on 6 patients with spinal cord angioma showed enhancement in 2 of them. The conditions to produce contrast enhancement were the window width of 100 - 200, and the window level of 0 - 50. In spinal cord angioma, contrast enhanced CT is presently only an adjunct to angiography and myelography. Nevertheless, contrast enhanced CT is useful in the screening test for spinal cord angioma, in the patients who are nonindicated to angiography, and in the postoperative follow-up. (Ueda, J.)

  3. Contrast enhancement CT by iopamidol

    International Nuclear Information System (INIS)

    Mori, Masaki; Makita, Nobue; Yanai, Kyoko

    1984-01-01

    In order to evaluate the contrast enhancement effect and safety of iopamidol (IOP) in CT examination, IOP was compared with angiographin (AG). In the liver and abdominal aorta, peak CT values were obtained earlier and were higher in the group with AG than in the group with IOP. However, CT values in the group with IOP decreased a little more slowly than those in the group with AG. There was no significant difference in the effect on contrast enhancement between the groups. Intravenous injection of IOP caused lower degree of burning sensation than that of AG, and some of the patients with IOP did not feel burning sensation at all. Changes in clinical laboratory values were slight before and after intravenous injection of IOP. These results suggest that IOP is satisfactory in terms of safety and effect on contrast enhancement in CT examination. (Namekawa, K.)

  4. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  5. CT of hepatocellular carcinoma. Analysis of contrast-enhanced CT using CT arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Hori, S; Tokunaga, K; Yoshioka, H [Osaka Univ. (Japan). Faculty of Medicine

    1981-02-01

    Although changes in the CT appearance resulting from contrast enhancement (CE) for hepatocellular carcinoma have been considered in association with vascularity of tumors, no detailed studies have yet been made. We analyzed changes in the CT appearance following CE by comparing with hepatic arteriogram and CT arteriogram (CTA) performed during intraarterial infusion of contrast medium. When tumors showing low density in the plain CT were enhanced by contrast, the results were variable, ranging from intensification of the low density to replacement by high density, and the results were classified into L/sub 0/ to L/sub 3/ according to vascularity of tumors. The results after CE could also be classified into I/sub 0/ to I/sub 3/ when tumors showed isodensity in the plain CT. There was a correlation between vascularity presumed from CE and vascularity by CTA. It may be concluded that tumor vascularity could be estimated by the findings of CE which might indicate a possibility of qualitative diagnosis of tumors.

  6. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    Directory of Open Access Journals (Sweden)

    Nicolas D. Prionas, MD, PhD

    2015-01-01

    Full Text Available Dedicated breast computed tomography (bCT generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obtained after diagnosis. Lesion enhancement at contrast-enhanced breast CT matched previously published enhancement values of breast cancer. Contrast-enhanced dedicated bCT provided high-resolution tomographic images and physiologic contrast enhancement data that facilitated the detection of an early breast cancer.

  7. Evaluation of residual hepatocellular carcinoma after transcatheter arterial chemoembolization: Comparison between contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography

    International Nuclear Information System (INIS)

    Kim, Seung Hoon; Lim, Hyo Keun; Lee, Won Jae

    2001-01-01

    To evaluate the effectiveness of contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography (PDUS) in assessing the therapeutic effect of transcatheter arterial chemoembolization (TACE) in hepatocellular carcinomas (HCCs). The follow-up contrast-enhanced helical CT and contrast-enhanced PDUS were performed for twenty-nine nodular HCCs from twelve patients previously treated with TACE. We defined the residual HCCs as intratumoral enhancing area on contrast-enhanced helical CT and color signal on contrast-enhanced PDUS. The interval between two examinations was less than 2 weeks (mean, 9 days). Two radiologists evaluated two examinations by consensus, and the results of these two examination were compared with the findings of other examinations including CT, angiography, and/or pathology to calculate the sensitivity, specificity and accuracy of two examinations. Of the 29 HCCs, 20 had residual HCCs whereas no residual HCCs in 9 HCCs on pathologic examination and/or follow-up radiologic study. The sensitivity, sensitivity and accuracy of contrast-enhanced helical CT were 65 (13/20), 89 (8/9), and 72% (21/29) while those of contrast-enhanced PDUS were 100 (20/20), 89 (8/9) and 97% (28/29), respectively. A microbubble contrast-enhanced PDUS was more effective in the detection of residual tumor in HCCs following TACE than contrast-enhanced helical CT.

  8. Is contrast-enhanced CT indicated in acute head injury

    International Nuclear Information System (INIS)

    Mauser, H.W.; Nieuwenhuizen, O. van; Veiga-Pires, J.A.

    1984-01-01

    The authors discuss the value of intravenous contrast enhancement in CT scanning in acute head injury. In a series of seventy consecutive patients they conclude that no incremental information was obtained by performing contrast-enhanced CT scans in the acute phase of the head injury. (orig.)

  9. Performance of integrated FDG-PET/contrast-enhanced CT in the staging and restaging of colorectal cancer: Comparison with PET and enhanced CT

    International Nuclear Information System (INIS)

    Dirisamer, Albert; Halpern, Benjamin S.; Floery, Daniel; Wolf, Florian; Beheshti, Mohsen; Mayerhoefer, Marius E.; Langsteger, Werner

    2010-01-01

    Objective: The purpose of this study was to assess the diagnostic value of PET/CT as a one step examination in patients with colorectal cancer. Therefore we proved whether diagnostic PET/CT adds information over PET or contrast-enhanced CT alone for staging or restaging of patients with colorectal cancer. Methods: Seventy-three patients (46 males and 27 females; age range: 50-81 years; mean age: 67 years) with known colorectal cancer underwent 18F-FDG-PET/CT for staging or restaging. Results: Of the 73 patients 26 patients underwent PET/CT for staging and 47 for restaging. 266 metastases could be detected in 60 patients. Contrast-enhanced PET/CT had a lesion-based sensitivity of 100%, contrast-enhanced CT of 91% and PET of 85%. PET/CT identified 2 lesions as false positive. PET/CT could also reach a patient-based sensitivity of 100%, which was superior to contrast-enhanced CT and PET. Conclusion: Our study clearly demonstrated the added value of contrast-enhanced PET/CT in staging and restaging patients with colorectal cancer over CT and PET alone.

  10. Evaluation of delayed contrast-enhanced CT scan in diagnosing hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Jianding; Liang Chenyang; Zhang Hua; Zhang Yuezhen; Li Rui

    2001-01-01

    Objective: To assess the diagnostic value of delayed CT contrast enhancement patterns in hilar cholangiocarcinoma based on two-phased dynamic incremental CT scanning. Methods: Fifty-two patients with suspected hilar tumor and bile duct obstruction underwent spiral CT scan. The scan time for one revolution of the X-ray tube was 1 second. To elucidate the delay time for optimal imaging, all proved cholangiocarcinoma with delayed (6, 8, 10, 15, 20, 30 minutes) post-equilibrium-phase contrast-enhanced CT scans were acquired with unenhanced, dynamic contrast-enhanced, and delayed images. Degree of delayed enhancement was compared with that of surrounding liver parenchyma. Results: (1) 8-15 minutes after IV injection of contrast material was the delay time for optimal imaging. (2) Of 29 cholangiocarcinomas, the early CT showed hypo-attenuating (lower than that of liver parenchyma) in 23 tumors, iso-attenuating (equal to that of the liver) in 4 tumors, and hyper-attenuating (higher than that of liver) in 2 tumors. The delayed CT scan showed iso-attenuating in 8 tumors, hyper-attenuating in 21 tumors, and no hypo-attenuating. Most of delay imaging of hilar cholangiocarcinoma may appear hyper-attenuating (U = -4.3073, P 2 = 9.09, P < 0.01). Conclusion: When assessing hilar tumor, delayed CT contrast enhancement patterns based on two-phase dynamic incremental CT scans is useful in the detection and characterization of hilar cholangiocarcinoma

  11. Diagnosis value of dual-phase contrast enhancement CT combined with virtual non-enhanced images by dual-energy CT in clear cell renal cell carcinoma

    International Nuclear Information System (INIS)

    Ma Zhoupeng; Zhou Jianjun; Liu Xueling; Wang Chun; Zhang Shunzhuang

    2012-01-01

    Objective: To explore the diagnostic value of dual-phase contrast enhancement CT combined with virtual non-enhanced images by dual-energy CT in clear cell renal cell carcinoma. Methods: Sixty patients who were suspected of clear cell renal cell carcinoma underwent non-enhanced CT and contrast enhancement CT of early interface-phase between cortex -medulla and parenchymal phase on a dual-energy CT. The true non-enhanced kidney CT (TNCT) was performed in a single-energy acquisition mode, but the dual-phase contrast enhancement CT were performed in a dual-energy mode of 80 kV and 140 kV respectively. The virtual non-enhanced CT (VNCT) images were derived from the data of early interface phase using liver virtual non-contrast software. The diagnose according to VNCT combined dual-phase contrast enhancement CT and dual-phase contrast enhancement CT only were made respectively and compared with χ 2 test. Between the true non-contrast CT and the virtual non-contrast CT, the image quality was compared with Wilcoxon test; The radiation dose of volume CT dose index (CTDIvol) and dose length product(DLP) in a single-phase and total examination, the mean CT HU values of the tumours were compared with t test. Results: The accuracy of VNCT combined dual-phase contrast enhancement CT was higher than that of dual-phase contrast enhancement CT only [93.3% (56/60) vs.78.3% (47/60); χ 2 =5.6, P<0.05]. The detective ability (score) of VNCT was near to that of TNCT and the difference was not obvious (Z=0.00, P>0.05). The radiation dose of volume CT dose index (CTDIvol) and dose length product (DLP) in a single phase and total examination of VNCT [(8.85 ± 1.28) mGy, (196.45 ±21.12) mGy·cm, (17.69±2.35) mGy, (392.90±42.25) mGy · cm] were lower than that of TNCT [(10.20 ± 1.44) mGy,(218.29 ± 29.60) mGy · cm, (30.61 ± 3.27) mGy and (654.86 ± 88.81) mGy ·cm], t=4.21, 3.58, 23.63, 16.12 respectively, P<0.05. The mean CT HU values of tumours on VNCT images was higher than that

  12. Sepsis patients' renal manifestation on contrast-enhanced CT

    International Nuclear Information System (INIS)

    Sasaguri, K.; Yamaguchi, K.; Nakazono, T.; Mizuguchi, M.; Irie, H.

    2016-01-01

    Aim: To evaluate renal volume and attenuation changes in patients with sepsis on contrast-enhanced computed tomography (CT) with respect to the severity of sepsis. Materials and methods: Forty-four patients with sepsis who underwent CT before and after the onset of sepsis were retrospectively analysed. Renal volume and CT attenuation value of the renal cortex on contrast-enhanced CT were measured for each patient and changes in renal volume and CT attenuation value from before to after the onset of sepsis were calculated. The changes were correlated with the severity of sepsis (Sepsis-related Organ Failure Assessment [SOFA] score). The time course of the renal volume and CT attenuation changes were also evaluated. Results: Renal volume increased by 17.6% and CT attenuation value decreased by 19% after the onset of sepsis with statistically significant differences (p<0.001 for both renal volume and CT attenuation changes). The renal volume and CT attenuation changes had significant correlations with the SOFA score (r=0.36, p=0.018 and −0.43, p=0.005, respectively). The time course of the renal volume and CT attenuation changes seemed to be gradual compared to that of the SOFA score and to lag behind the peak of the SOFA score. Conclusion: In patients with sepsis, the renal volume increases and the CT attenuation value decreases in proportion to the severity of sepsis. The changes may lag behind the peak of severity of sepsis and can be observed for a relatively long time after a patient's recovery from sepsis. - Highlights: • The renal volume increases and the renal enhancement on contrast-enhanced CT decreases in patients with sepsis. • The degrees of these changes are correlated with severity of sepsis. • These changes may lag behind the peak of severity of sepsis and last for a long time after a patient's recovery from sepsis.

  13. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Prognostic significance of contrast-enhanced CT attenuation value in extrahepatic cholangiocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Asayama, Yoshiki [Kyushu University, Department of Advanced Imaging and Interventional Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Nishie, Akihiro; Ishigami, Kousei; Ushijima, Yasuhiro; Takayama, Yukihisa; Okamoto, Daisuke; Fujita, Nobuhiro; Honda, Hiroshi [Kyushu University, Departments of Clinical Radiology, Fukuoka (Japan); Ohtsuka, Takao [Kyushu University, Departments of Surgery and Oncology, Fukuoka (Japan); Yoshizumi, Tomoharu [Kyushu University, Departments of Surgery and Sciences, Fukuoka (Japan); Aishima, Shinichi [Saga University, Pathology and Microbiology, Faculty of Medicine, Saga (Japan); Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan); Oda, Yoshinao [Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2017-06-15

    To determine whether washout characteristics of dynamic contrast-enhanced computed tomography (CT) could predict survival in patients with extrahepatic cholangiocarcinoma (EHC). This study collected 46 resected cases. All cases were examined by dynamic contrast study on multidetector-row CT. Region-of-interest measurements were obtained at the non-enhanced, portal venous phase and delayed phase in the tumour and were used to calculate the washout ratio as follows: [(attenuation value at portal venous phase CT - attenuation value at delayed enhanced CT)/(attenuation value at portal venous phase CT - attenuation value at unenhanced CT)] x 100. On the basis of the median washout ratio, we classified the cases into two groups, a high-washout group and low-washout group. Associations between overall survival and various factors including washout rates were analysed. The median washout ratio was 29.4 %. Univariate analysis revealed that a lower washout ratio, venous invasion, lymphatic permeation and lymph node metastasis were associated with shorter survival. Multivariate analysis identified the lower washout ratio as an independent prognostic factor (hazard ratio, 3.768; p value, 0.027). The washout ratio obtained from the contrast-enhanced CT may be a useful imaging biomarker for the prediction of survival of patients with EHC. (orig.)

  15. The value of contrast-enhanced CT scan in prediction of development of contusional hemorrhage

    International Nuclear Information System (INIS)

    Yokoyama, Kazuhiro; Kyoi, Kikuo; Sakaki, Toshisuke; Kinugawa, Kazuhiko; Morimoto, Tetsuya

    1983-01-01

    It is often experienced that even if there are no significant findings on the initial plain CT scan in the patient with cerebral contusion, the patient has thereafter a serious clinical course and requires emergency operation for so-called contusional hemorrhage. In order to predict of the development of contusional hemorrhage we performed contrast-enhanced CT scan at the time of patient's arrival within 12 hours after injury, if there was cerebral contusion on the initial plain CT scan, and repeated plain CT scan 24 hours after the contrast-enhanced CT scan. If enhancement was demonstrated on the contrastenhanced CT scan, we predicted the development of contusional hemorrhage and if not demonstrated, we predicted no more development of contusional hemorrhage and then we studied the correlation between the prediction and the plain CT 24 hours after the contrast-enhanced CT scan. The results were as follows: 1) The prediction was correct in 13 cases out of 16 cases in which the development of contusional hemorrhage was observed. In 18 cases where no development of contusional hemorrhage was observed, the prediction was correct without exception. 2) Most of the cases in which enhancement was demonstrated were ones examined not before 3 hours after injury. 3) The extent of enhancement shown on contrastenhanced CT scan was well consistent with that of contusional hemorrhage on the plain CT scan 24 hours after the contrast-enhanced CT scan. From these results, the contrast-enhanced CT scan in acute stage of head injury was considered to by very useful in prediction of the development of contusional hemorrhage. (author)

  16. CT findings in autoimmune pancreatitis: assessment using multiphase contrast-enhanced multisection CT

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K., E-mail: Kojiro@med.nagoya-u.ac.j [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Itoh, S. [Department of Radiology, Nagoya Hirokoji Clinic, Nagoya (Japan); Nagasaka, T. [Departments of Medical Technology, Nagoya University School of Health Science, Nagoya (Japan); Ogawa, H.; Ota, T.; Naganawa, S. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2010-09-15

    Aim: To assess the spectrum of findings using multiphase contrast-enhanced computed tomography (CT) in patients with autoimmune pancreatitis (AIP). Materials and methods: Fifty patients (four female and 46 male, mean age 65 years) were retrospectively identified from consecutive patients with abnormal CT findings of the pancreas and negative work-up for known causes. These patients had at least one finding supporting the diagnosis of AIP: serological abnormality, histopathological abnormality, or response to steroid. Two radiologists evaluated multiphase contrast-enhanced CT images in consensus. Results: The pancreas showed diffuse enlargement (n = 16; 32%), focal enlargement (n = 18; 36%), or no enlargement (n = 16; 32%). Forty-nine (98%) patients showed abnormal contrast enhancement in the affected pancreatic parenchyma, including hypoattenuation during the pancreatic phase (n = 45; 90%) and hyperattenuation during the delayed phase (n = 39; 87%). The following findings were also seen in the pancreas: a capsule-like rim (n = 24; 48%); no visualization of the main pancreatic duct lumen (n = 48; 96%); ductal enhancement (n = 26; 52%); upstream dilatation of the main pancreatic duct (n = 27; 54%); upstream atrophy of the pancreatic parenchyma (n = 27; 54%); calcification (n = 7; 14%); and cysts (n = 5; 10%). Forty-two (84%) patients showed one or more of the following extrapancreatic findings: biliary duct or gallbladder abnormality (n = 40; 80%); peripancreatic (n = 8; 16%) or para-aortic (n = 10; 20%) soft-tissue proliferation; and renal involvement (n = 15; 30%). Conclusion: Patients with AIP presented with a variety of CT findings in the pancreas and the extrapancreatic organs. The present study highlights pancreatic ductal enhancement in a subset of patients with AIP.

  17. Meta-analysis: Serum creatinine changes following contrast enhanced CT imaging

    International Nuclear Information System (INIS)

    Kooiman, Judith; Pasha, Sharif M.; Zondag, Wendy; Sijpkens, Yvo W.J.; Molen, Aart J. van der; Huisman, Menno V.; Dekkers, Olaf M.

    2012-01-01

    Purpose: Contrast induced nephropathy (CIN) is defined as a decrease in renal function following administration of contrast media. The aim of this meta-analysis was to asses the overall risk of CIN, chronic loss of kidney function and the need for renal replacement therapy (RRT) after intravenous contrast enhanced CT-scan. Secondly, we aimed to identify subgroups at increased risk for CIN. Materials and methods: A literature search in Pubmed, Medline, Embase and Cochrane databases was performed. Data extraction was carried out independently by two reviewers. Meta-analysis and meta-regression were performed using an exact likelihood approach. Results: Forty studies evaluating the incidence of CIN after CT were included. The pooled incidence of CIN was 6.4% (95% CI 5.0–8.1). The risk of RRT after CIN was low, 0.06% (95% CI 0.01–0.4). The decline in renal function persisted in 1.1% of patients (95% CI 0.6–2.1%). Patients with chronic kidney disease (odds ratio 2.26, p < 0.001) or diabetes mellitus (odds ratio 3.10, p < 0.001) were at increased risk for the development of CIN. Conclusion: CIN occurred in 6% of patients after contrast enhanced CT. In 1% of all patients undergoing contrast enhanced CT the decline in renal function persisted

  18. Meta-analysis: Serum creatinine changes following contrast enhanced CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kooiman, Judith, E-mail: j.kooiman@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Pasha, Sharif M., E-mail: s.m.pasha@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Zondag, Wendy, E-mail: w.zondag@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Sijpkens, Yvo W.J., E-mail: ysijpens@bronovo.nl [Department of Nephrology, Bronovo Hospital, The Hague (Netherlands); Molen, Aart J. van der, E-mail: molen@lumc.nl [Department of Radiology, LUMC, Leiden (Netherlands); Huisman, Menno V., E-mail: m.v.huisman@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Dekkers, Olaf M., E-mail: o.m.dekkers@lumc.nl [Department of Clinical Epidemiology and Department of Endocrinology, LUMC, Leiden (Netherlands)

    2012-10-15

    Purpose: Contrast induced nephropathy (CIN) is defined as a decrease in renal function following administration of contrast media. The aim of this meta-analysis was to asses the overall risk of CIN, chronic loss of kidney function and the need for renal replacement therapy (RRT) after intravenous contrast enhanced CT-scan. Secondly, we aimed to identify subgroups at increased risk for CIN. Materials and methods: A literature search in Pubmed, Medline, Embase and Cochrane databases was performed. Data extraction was carried out independently by two reviewers. Meta-analysis and meta-regression were performed using an exact likelihood approach. Results: Forty studies evaluating the incidence of CIN after CT were included. The pooled incidence of CIN was 6.4% (95% CI 5.0–8.1). The risk of RRT after CIN was low, 0.06% (95% CI 0.01–0.4). The decline in renal function persisted in 1.1% of patients (95% CI 0.6–2.1%). Patients with chronic kidney disease (odds ratio 2.26, p < 0.001) or diabetes mellitus (odds ratio 3.10, p < 0.001) were at increased risk for the development of CIN. Conclusion: CIN occurred in 6% of patients after contrast enhanced CT. In 1% of all patients undergoing contrast enhanced CT the decline in renal function persisted.

  19. Differential diagnosis between pulmonary tuberculosis and lung abscess by contrast enhanced CT

    International Nuclear Information System (INIS)

    Kanauchi, Tetsu; Hoshi, Toshiko; Konno, Miyuki; Hando, Yumiko

    2001-01-01

    The contrast enhanced CT findings in 14 patients with active tuberculosis and 26 patients with lung abscess were retrospectively analyzed. Reflecting the difference of pathogenesis between tuberculosis and abscess, the findings are widely different. The findings suggesting pulmonary tuberculosis rather than lung abscess were as follows; multiple and irregular necrotic areas, positive CT angiogram sign, no marginal enhancement surrounding necrosis. Contrast enhanced CT may help to distinguish pulmonary tuberculosis from lung abscess, especially in cases of caseous pneumonia showing broad consolidations or mass-like shadows. (author)

  20. Applications of contrast enhanced CT through external jugular access

    International Nuclear Information System (INIS)

    Xu Qiaolan; Zou Wenxing; Chen Meixia; Xie Hongbo

    2005-01-01

    Objective: A retrospective analysis and evaluation for the effects of contrast enhanced computed tomography through external jugular access. Methods: 1250 cases (male 692 and female 558) underwent CT contrast enhanced examination were retrospectively reviewed from May, 2002 to Oct, 2002. The patients aged from 12 to 86 years, averagely 49 years. Contrast agent (Ultravist) was given through an intravenous catheter placed in the cubital vein. Precise injection rates were ensured by a power injector (Medrad MCT310, USA). Excellent enhancement was achieved with this protocol in most of the patients, while external jugular access was established in 96 cases because it was unable to setup a cubital venous access. Results: Good enhancement were acquired when 96 cases of contrast agent injected through external jugular vein. And the external jugular access was setup successfully with a single puncture. Conclusion: It is a common occasion when patient undergoing contrast enhanced CT scan is in poor conditions: debility, cachexia, or with complication of chemotherapy or radiation therapy, which often results in invalidity of cabital venous access, and consequently, making bolus injection impossible. The external jugular vein is a large and central blood vessel, which is easy to setup an access. In our experience, an external jugular access should be recommended as a substitution if the cubital venous access is not available. (authors)

  1. Applications of contrast enhanced CT through external jugular access

    Energy Technology Data Exchange (ETDEWEB)

    Qiaolan, Xu; Wenxing, Zou; Meixia, Chen; Hongbo, Xie [The First Affiliated Hospital of Sun Yat-sen University, Guangzhou (China). Dept. of Radiology

    2005-09-15

    Objective: A retrospective analysis and evaluation for the effects of contrast enhanced computed tomography through external jugular access. Methods: 1250 cases (male 692 and female 558) underwent CT contrast enhanced examination were retrospectively reviewed from May, 2002 to Oct, 2002. The patients aged from 12 to 86 years, averagely 49 years. Contrast agent (Ultravist) was given through an intravenous catheter placed in the cubital vein. Precise injection rates were ensured by a power injector (Medrad MCT310, USA). Excellent enhancement was achieved with this protocol in most of the patients, while external jugular access was established in 96 cases because it was unable to setup a cubital venous access. Results: Good enhancement were acquired when 96 cases of contrast agent injected through external jugular vein. And the external jugular access was setup successfully with a single puncture. Conclusion: It is a common occasion when patient undergoing contrast enhanced CT scan is in poor conditions: debility, cachexia, or with complication of chemotherapy or radiation therapy, which often results in invalidity of cabital venous access, and consequently, making bolus injection impossible. The external jugular vein is a large and central blood vessel, which is easy to setup an access. In our experience, an external jugular access should be recommended as a substitution if the cubital venous access is not available. (authors)

  2. Prevalence and characteristics of intravertebral enhancement on contrast-enhanced CT scans in cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Rasselet, Benjamin [Medical Imaging Department and Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France); Larbi, Ahmed; Viala, Pierre [Medical Imaging Department, Nimes University Hospital, 4 rue du Professeur Robert Debré, 30029 Nîmes (France); Molinari, Nicolas [Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France); Tetreau, Raphael [Medical Imaging Department, Montpellier Cancer Institute (ICM), 208 Avenue des Apothicaires, 34298 Montpellier Cedex 5 (France); Faruch-Bilfeld, Marie [Medical Imaging Department, Toulouse University Hospital, Place du Docteur Baylac, 31059 Toulouse Cedex 9 (France); Taourel, Patrice [Medical Imaging Department and Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France); Cyteval, Catherine, E-mail: c-cyteval@chu-montpellier.fr [Medical Imaging Department and Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France)

    2017-01-15

    Highlights: • 2.8% of collateral venous circulation seen on CT scan in a cancer population. • 37% of intravertebral enhancement in this population with collateral venous circulation. • 80.8% of intravertebral enhancements are located between C6 and. • 73% of intravertebral enhancements are located ipsilateral to the injection side. -  Abstract: Study design: This was a single center, retrospective observational study. Objective: to investigate—in a cancer population—the prevalence and hallmarks of intravertebral enhancement (IVE) detected on contrast-enhanced CT. Summary of background data: Intravertebral enhancements secondary to iodinated contrast stagnation have been described. Cancer patients have an increased risk of perivertebral venous thrombosis or stenosis secondary to several risk factors (cancer or drug induced hypercoagulability, deterioration of venous flow linked to catheter insertion, prolonged immobilization). In case of a high density lesion identified on CT, the diagnostic choice between metastasis and contrast media within bone marrow vessels may be an issue, especially as oncologic follow-up CT scans are usually performed with contrast medium injection. Methods: 2572 contrast-enhanced body CT scans performed in cancer patients over 3 months in the medical imaging department of a university hospital were retrospectively reviewed. IVE was sought when paravertebral venous collateral circulation was detected and bone metastasis ruled out and classified as linear or nodular. Their locations within vertebra, their relation to the injection side and the predominant collateral venous network side were evaluated. Results: Sixty-seven (2.8%) patients had a collateral paravertebral venous system and among them 21 had IVE (37%). There were 208 IVE locations involving 75 vertebrae. 199 IVE were linear-shaped (95.7%) and 9 nodular-shaped (4.3%). 80.8% were located between C6 and T4. 88.9% were localized in the vertebral body. 73.1% were located

  3. Prevalence and characteristics of intravertebral enhancement on contrast-enhanced CT scans in cancer patients

    International Nuclear Information System (INIS)

    Rasselet, Benjamin; Larbi, Ahmed; Viala, Pierre; Molinari, Nicolas; Tetreau, Raphael; Faruch-Bilfeld, Marie; Taourel, Patrice; Cyteval, Catherine

    2017-01-01

    Highlights: • 2.8% of collateral venous circulation seen on CT scan in a cancer population. • 37% of intravertebral enhancement in this population with collateral venous circulation. • 80.8% of intravertebral enhancements are located between C6 and. • 73% of intravertebral enhancements are located ipsilateral to the injection side. -  Abstract: Study design: This was a single center, retrospective observational study. Objective: to investigate—in a cancer population—the prevalence and hallmarks of intravertebral enhancement (IVE) detected on contrast-enhanced CT. Summary of background data: Intravertebral enhancements secondary to iodinated contrast stagnation have been described. Cancer patients have an increased risk of perivertebral venous thrombosis or stenosis secondary to several risk factors (cancer or drug induced hypercoagulability, deterioration of venous flow linked to catheter insertion, prolonged immobilization). In case of a high density lesion identified on CT, the diagnostic choice between metastasis and contrast media within bone marrow vessels may be an issue, especially as oncologic follow-up CT scans are usually performed with contrast medium injection. Methods: 2572 contrast-enhanced body CT scans performed in cancer patients over 3 months in the medical imaging department of a university hospital were retrospectively reviewed. IVE was sought when paravertebral venous collateral circulation was detected and bone metastasis ruled out and classified as linear or nodular. Their locations within vertebra, their relation to the injection side and the predominant collateral venous network side were evaluated. Results: Sixty-seven (2.8%) patients had a collateral paravertebral venous system and among them 21 had IVE (37%). There were 208 IVE locations involving 75 vertebrae. 199 IVE were linear-shaped (95.7%) and 9 nodular-shaped (4.3%). 80.8% were located between C6 and T4. 88.9% were localized in the vertebral body. 73.1% were located

  4. The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging. Implications for CT dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Perisinakis, Kostas; Damilakis, John [University of Crete, Department of Medical Physics, Medical School, Heraklion, Crete (Greece); University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Tzedakis, Antonis; Papadakis, Antonios E. [University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Spanakis, Kostas [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); Hatzidakis, Adam [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); University of Crete, Department of Radiology, Medical School, Heraklion, Crete (Greece)

    2018-01-15

    To investigate the effect of iodine uptake on tissue/organ absorbed doses from CT exposure and its implications in CT dosimetry. The contrast-induced CT number increase of several radiosensitive tissues was retrospectively determined in 120 CT examinations involving both non-enhanced and contrast-enhanced CT imaging. CT images of a phantom containing aqueous solutions of varying iodine concentration were obtained. Plots of the CT number increase against iodine concentration were produced. The clinically occurring iodine tissue uptake was quantified by attributing recorded CT number increase to a certain concentration of aqueous iodine solution. Clinically occurring iodine uptake was represented in mathematical anthropomorphic phantoms. Standard 120 kV CT exposures were simulated using Monte Carlo methods and resulting organ doses were derived for non-enhanced and iodine contrast-enhanced CT imaging. The mean iodine uptake range during contrast-enhanced CT imaging was found to be 0.02-0.46% w/w for the investigated tissues, while the maximum value recorded was 0.82% w/w. For the same CT exposure, iodinated tissues were found to receive higher radiation dose than non-iodinated tissues, with dose increase exceeding 100% for tissues with high iodine uptake. Administration of iodinated contrast medium considerably increases radiation dose to tissues from CT exposure. (orig.)

  5. Value of contrast enhanced CT scanning in the non-trauma emergency room patient

    International Nuclear Information System (INIS)

    Wood, L.P.; Parisi, M.; Finch, I.J.

    1990-01-01

    To determine the value of performing contrast CT in addition to non-contrast CT in the evaluation of acute non-traumatic central nervous system disorders, we retrospectively reviewed 322 cases originating from the emergency room at our institution. The most common indication for scanning was seizure activity (34% of total), followed by headache (30%), focal neurological deficit (10%), and altered mental status (8%). 75% of the noncontrast scans were normal. The contrast enhanced scan revealed abnormalities not evident on the non-contrast scan in only three of these cases, and the information did not alter patient management. We conclude that in the acute setting, if a non-contrast CT is normal, a contrast study is usually unnecessary. Therefore, given the additional risks of contrast infusion, the contrast study, if needed, is generally best obtained at a later date, after more careful evaluation of the patient's history and medical records. If the non-contrast CT scan is abnormal, a contrast enhanced CT scan may be beneficial, but, again, is often not needed to direct acute patient management. (orig.)

  6. Pulmonary CT angiography: optimization of contrast enhancement technique

    International Nuclear Information System (INIS)

    Ma Lianju; Tang Guangjian; Fu Jiazhen

    2012-01-01

    Objective: To derive and evaluate the formula of exactly calculating the contrast dosage used during pulmonary CT angiography (CTPA). Methods: Time density curves in 27 patients who underwent CTPA were collected and analyzed,the formula for calculating contrast dosage during CTPA was derived. 68 patients suspected of pulmonary embolism (PE) clinically but no PE on CTPA were divided randomly into group A, with bolus tracing technique (n=26), and group B, with small dose injection contrast test (SDCT) (n=42). The CT values of the right main pulmonary artery (RMPA), right upper pulmonary vein (RUPV), right posterior basal PA, right lower PV (RLPV) and the aorta were calculated. The total contrast dosage and the hard beam artifact in the SVC were compared between the two groups.Student's t test, Chi-square test and Mann-Whitney U test were used. Results: The ratio of the time from starting injection to enhancement peak of caudal end of SVC and the time to enhancement peak of the main pulmonary trunk was 0.65 ±0.09 (about 2/3), the formula for contrast dosage calculation was derived as (DTs/3 + STs/2) FR ml/s. The CT values of RMPA and RLPA between the two groups [(301 ±117), (329 ± 122) and (283 ±95), (277 ±98) HU respectively] were not significantly different (t=1.060, P=0.292; t=2.056, P=0.044), but the differences of CT values in the paired PA and PV between the two groups (median were 22.5, 58.0 and 170.5, 166.5 HU respectively) were significant (U=292, P=0.001 and U=325, P=0.005), contrast artifact of the SVC (grade 1-3) in group B (n=34, 7, 1 respectively) was significantly less than in group A (n=11, 10, 5 respectively, χ 2 =10.714, P=0.002), the contrast dosage injected in group A was ( 87.6 ± 7.3) ml, and in group B was (40.0 ±5.4) ml (P<0.01). Conclusion: CTPA with SDCT technique is superior to that with conventional bolus tracing technique regarding contrast dosage and contrast artifact in the SVC. (authors)

  7. Cranial CT revisited: do we really need contrast enhancement?

    International Nuclear Information System (INIS)

    Demaerel, P.; Buelens, C.; Wilms, G.; Baert, A.L.

    1998-01-01

    The aim of this study was to define guidelines for intravenous contrast administration in cranial CT, as currently there are no recent guidelines based on a large series of patients. In 1900 consecutive patients (1480 adults and 420 children) pre- and post-contrast scan was analysed in order to assess the contribution of contrast enhancement to the diagnosis. The findings were grouped according to whether abnormalities were seen on the pre- and/or post-contrast scan, or whether no abnormalities were seen at all. Sensitivity, specificity, positive predictive value, negative predictive value and accurracy of a pre-contrast scan were used to determine validity. Intravenous contrast enhancement only contributes to the diagnosis if a suspicious abnormality is seen on the unenhanced scan or in the appropriate clinical setting (33.6 %). In the remaining patients (65.6 %) there is no diagnostic contribution, except for a small number of abnormalities (0.8 %). These are often anatomical variants and have no therapeutic impact. The number of contrast-enhanced cranial CT examinations can significantly be reduced by using four general guidelines for contrast administration resulting in considerable cost savings without affecting the quality of service to the patient. These guidelines are defined by the clinical findings/presentation or by the findings on the unenhanced scan. The number of contrast-related complications will be reduced, which may have medicolegal implications. These guidelines can be applied in any radiology department. (orig.) (orig.)

  8. Predicting IDH mutation status of intrahepatic cholangiocarcinomas based on contrast-enhanced CT features

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yong [Nanjing Drum Tower Hospital Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Department of Radiology, Nanjing, Jiangsu Province (China); Chen, Jun [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Pathology, Nanjing, Jiangsu Province (China); Kong, Weiwei [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Oncology, Nanjing, Jiangsu Province (China); Mao, Liang; Qiu, Yudong [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Hepatopancreatobiliary Surgery, Nanjing, Jiangsu Province (China); Kong, Wentao [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Ultrasonography, Nanjing, Jiangsu Province (China); Zhou, Qun [Nanjing Drum Tower Hospital Clinical College of Nanjing Medical University, Department of Radiology, Nanjing, Jiangsu Province (China); Zhou, Zhengyang; Zhu, Bin; He, Jian [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Radiology, Nanjing, Jiangsu Province (China); Wang, Zhongqiu [Jiangsu Province Hospital of Traditional Chinese Medicine, the Affiliated Hospital of Nanjing University of Chinese Medicine, Department of Radiology, Nanjing, Jiangsu Province (China)

    2018-01-15

    To explore the difference in contrast-enhanced computed tomography (CT) features of intrahepatic cholangiocarcinomas (ICCs) with different isocitrate dehydrogenase (IDH) mutation status. Clinicopathological and contrast-enhanced CT features of 78 patients with 78 ICCs were retrospectively analysed and compared based on IDH mutation status. There were 11 ICCs with IDH mutation (11/78, 14.1%) and 67 ICCs without IDH mutation (67/78, 85.9%). IDH-mutated ICCs showed intratumoral artery more often than IDH-wild ICCs (p = 0.023). Most ICCs with IDH mutation showed rim and internal enhancement (10/11, 90.9%), while ICCs without IDH mutation often appeared diffuse (26/67, 38.8%) or with no enhancement (4/67, 6.0%) in the arterial phase (p = 0.009). IDH-mutated ICCs showed significantly higher CT values, enhancement degrees and enhancement ratios in arterial and portal venous phases than IDH-wild ICCs (all p < 0.05). The CT value of tumours in the portal venous phase performed best in distinguishing ICCs with and without IDH mutation, with an area under the curve of 0.798 (p = 0.002). ICCs with and without IDH mutation differed significantly in arterial enhancement mode, and the tumour enhancement degree on multiphase contrast-enhanced CT was helpful in predicting IDH mutation status. (orig.)

  9. PET/CT in malignant melanoma: contrast-enhanced CT versus plain low-dose CT

    International Nuclear Information System (INIS)

    Pfluger, Thomas; Schneider, Vera; Fougere, Christian la; Bartenstein, Peter; Weiss, Mayo; Melzer, Henriette Ingrid; Coppenrath, Eva; Berking, Carola

    2011-01-01

    The aim of this study was to evaluate the diagnostic value of contrast-enhanced CT (CECT) versus non-enhanced low-dose CT (NECT) in the staging of advanced malignant melanoma with 18 F-fluordeoxyglucose (FDG) positron emission tomography (PET)/CT. In total, 50 18 F-FDG PET/CT examinations were performed in 50 patients with metastasized melanoma. For attenuation correction, whole-body NECT was performed followed by diagnostic CECT with contrast agent. For the whole-body PET, 18 F-FDG was applied. Criteria for evaluation were signs of vital tumour tissue (extent of lesions, contrast enhancement, maximum standardized uptake value >2.5). Findings suspicious for melanoma were considered lesions. NECT, CECT and 18 F-FDG PET were evaluated separately, followed by combined analysis of PET/NECT and PET/CECT. Findings were verified histologically and/or by follow-up (>6 months). Overall, 232 lesions were analysed, and 151 proved to be metastases. The sensitivity of NECT, CECT, PET, PET/NECT and PET/CECT was 62, 85, 90, 97 and 100%, and specificity was 52, 63, 88, 93 and 93%, respectively. Compared to CECT, NECT obtained additional false-negative results: lymph node (n = 19) and liver/spleen metastases (n = 9). Misinterpreted physiological structures mainly caused additional false-positive findings (n = 17). In combined analysis of PET/NECT, six false-positive [other tumours (n = 2), inflammatory lymph nodes (n = 2), inflammatory lung lesion (n = 1), blood vessel (n = 1)] and five false-negative findings [liver (n = 3), spleen (n = 1), lymph node metastases (n = 1)] remained. On PET/CECT, six false-positive [inflammatory lymph nodes (n = 3), other tumours (n = 2), inflammatory lung lesion (n = 1)] and no false-negative findings occurred. However, additional false findings on PET/NECT (6 of 232) did not change staging compared to PET/CECT. Our results indicate that it is justified to perform PET/NECT instead of PET/CECT for melanoma staging. (orig.)

  10. Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Aschoff, Philip; Plathow, Christian; Lichy, Matthias P.; Claussen, Claus D.; Pfannenberg, Christina; Beyer, Thomas; Erb, Gunter; Oeksuez, Mehmet Oe.

    2012-01-01

    State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of 18 F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications. (orig.)

  11. FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT

    Directory of Open Access Journals (Sweden)

    Canh Nguyen

    2015-01-01

    Full Text Available Objective(s: In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT, complicating hepatocellular carcinoma (HCC in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT, which is a combination of dynamic liver CT scan, multiphase imaging, and whole-body PET scan. PET and CT DICOM images of patients were imported into the PET/CT imaging system for the re-analysis of contrast enhancement and FDG uptake in thrombus, the diameter of the involved portal vein, and characteristics of liver tumors and metastasis. Results: Two patients with previously untreated HCC and 7 cases with previously treated HCC had FDG-avid PVTT in contrast-enhanced FDG PET/CT scan. During the arterial phase of CT scan, portal vein thrombus showed contrast enhancement in 8 out of 9 patients (88.9%. PET scan showed an increased linear FDG uptake along the thrombosed portal vein in all patients. The mean greatest diameter of thrombosed portal veins was 1.8 ± 0.2 cm, which was significantly greater than that observed in normal portal veins (P<0.001. FDG uptake level in portal vein thrombus was significantly higher than that of blood pool in the reference normal portal vein (P=0.001. PVTT was caused by the direct extension of liver tumors. All patients had visible FDG-avid liver tumors in contrast-enhanced images. Five out of 9 patients (55.6% had no extrahepatic metastasis, 3 cases (33.3% had metastasis of regional lymph nodes, and 1 case (11.1% presented with distant metastasis. The median estimated survival time of patients was 5 months. Conclusion: The intraluminal filling defect consistent with thrombous within the portal vein, expansion of the involved portal vein, contrast enhancement, and linear increased FDG uptake of the thrombus extended from liver tumor are

  12. Dual-energy computed tomography for the assessment of early treatment effects of regorafenib in a preclinical tumor model: comparison with dynamic contrast-enhanced CT and conventional contrast-enhanced single-energy CT

    International Nuclear Information System (INIS)

    Knobloch, Gesine; Hamm, Bernd; Jost, Gregor; Pietsch, Hubertus; Huppertz, Alexander

    2014-01-01

    The potential diagnostic value of dual-energy computed tomography (DE-CT) compared to dynamic contrast-enhanced CT (DCE-CT) and conventional contrast-enhanced CT (CE-CT) in the assessment of early regorafenib treatment effects was evaluated in a preclinical setting. A rat GS9L glioma model was examined with contrast-enhanced dynamic DE-CT measurements (80 kV/140 kV) for 4 min before and on days 1 and 4 after the start of daily regorafenib or placebo treatment. Tumour time-density curves (0-240 s, 80 kV), DE-CT (60 s) derived iodine maps and the DCE-CT (0-30 s, 80 kV) based parameters blood flow (BF), blood volume (BV) and permeability (PMB) were calculated and compared to conventional CE-CT (60 s, 80 kV). The regorafenib group showed a marked decrease in the tumour time-density curve, a significantly lower iodine concentration and a significantly lower PMB on day 1 and 4 compared to baseline, which was not observed for the placebo group. CE-CT showed a significant decrease in tumour density on day 4 but not on day 1. The DE-CT-derived iodine concentrations correlated with PMB and BV but not with BF. DE-CT allows early treatment monitoring, which correlates with DCE-CT. Superior performance was observed compared to single-energy CE-CT. circle Regorafenib treatment response was evaluated by CT in a rat tumour model. (orig.)

  13. Dual-energy computed tomography for the assessment of early treatment effects of regorafenib in a preclinical tumor model: comparison with dynamic contrast-enhanced CT and conventional contrast-enhanced single-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Knobloch, Gesine; Hamm, Bernd [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Jost, Gregor; Pietsch, Hubertus [Bayer Healthcare, MR and CT Contrast Media Research, Berlin (Germany); Huppertz, Alexander [Imaging Science Institute Charite - Siemens, Berlin (Germany)

    2014-08-15

    The potential diagnostic value of dual-energy computed tomography (DE-CT) compared to dynamic contrast-enhanced CT (DCE-CT) and conventional contrast-enhanced CT (CE-CT) in the assessment of early regorafenib treatment effects was evaluated in a preclinical setting. A rat GS9L glioma model was examined with contrast-enhanced dynamic DE-CT measurements (80 kV/140 kV) for 4 min before and on days 1 and 4 after the start of daily regorafenib or placebo treatment. Tumour time-density curves (0-240 s, 80 kV), DE-CT (60 s) derived iodine maps and the DCE-CT (0-30 s, 80 kV) based parameters blood flow (BF), blood volume (BV) and permeability (PMB) were calculated and compared to conventional CE-CT (60 s, 80 kV). The regorafenib group showed a marked decrease in the tumour time-density curve, a significantly lower iodine concentration and a significantly lower PMB on day 1 and 4 compared to baseline, which was not observed for the placebo group. CE-CT showed a significant decrease in tumour density on day 4 but not on day 1. The DE-CT-derived iodine concentrations correlated with PMB and BV but not with BF. DE-CT allows early treatment monitoring, which correlates with DCE-CT. Superior performance was observed compared to single-energy CE-CT. circle Regorafenib treatment response was evaluated by CT in a rat tumour model. (orig.)

  14. Experience with contrast-enhanced CT in delayed traumatic intracerebral hematoma

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Shiro; Nakazawa, Shozo; Yokota, Hiroyuki; Isayama, Kazuo; Yajima, Kouzo; Otsuka, Toshibumi [Nippon Medical School, Tokyo

    1984-02-01

    During the four-and-a-half-year period from April, 1976, to September, 1980, out of 257 patients with severe head injuries graded 8 or less by the Glasgow Coma Scale in the Department of Neurosurgery and Critical Care Medicine of the Nippon Medical School, Tokyo, Japan, 33 cases showed the development of delayed traumatic intracerebral hematoma (DTICH) upon the serial computerized tomography (CT). Contrast-enhanced CT was performed in 20 cases of the 33 patients demonstrating DTICH. Among these, 8 cases (40%) indicated the development of DTICH in the lesions of cerebral contusion (a salt-and-pepper appearance in the initial plain CT) which showed a remarkable enhancement, sustaining the extravasation of the contrast medium into the contused brain tissue. The authors discuss the pathogenesis of DTICH and suggest that vasoparalysis in the cerebral contusion might be a factor in the development of DTICH in patients with servere head injuries.

  15. CT angiography. Abdominal CT using intravenous aortography for contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, J; Nakauma, Y; Egawa, J; Kawamura, M [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    1980-04-01

    To obtain imaging effects close to those of abdominal aortography and investigate a technique with little invasion to patients, intravenous aortography was applied to contrast enhancement (CE) in abdominal CT, and its usefulness was discussed. Intravenous aortography could clearly visualize lesions with rich neovascularity such as hepatocellular carcinoma and renal cell carcinoma. Differing from a drip infusion method, this method has complexities in its technique that contrast medium is injected at once, blood circulation time which is represented by the time between the injection and the time when the patients feel bitterness (10 - 12 seconds) must be measured before CE, and scanning begins 2 seconds before the patients feel bitterness. However, the invasion to patients due to this method is slight, and the capacity of this method to visualize neovascularity is superior to CE by a drip infusion method. Therefore, qualitative diagnosis by CT will be improved by using this method together with a drip infusion method.

  16. Contrast between hypervascularized liver lesions and hepatic parenchyma. Early dynamic PET versus contrast-enhanced CT

    International Nuclear Information System (INIS)

    Freesmeyer, M.; Winkens, T.; Schierz, J.-H.

    2014-01-01

    To detect hypervascularized liver lesions, early dynamic (ED) 18 F-FDG PET may be an alternative when contrast-enhanced (CE) imaging is infeasible. This retrospective pilot analysis compared contrast between such lesions and liver parenchyma, an important objective image quality variable, in ED PET versus CE CT. Twenty-eight hypervascularized liver lesions detected by CE CT [21 (75%) hepatocellular carcinomas; mean (range) diameter 4.9 ± 3.5 (1-14) cm] in 20 patients were scanned with ED PET. Using regions of interest, maximum and mean lesional and parenchymal signals at baseline, arterial and venous phases were calculated for ED PET and CE CT. Lesional/parenchymal signal ratio was significantly higher (P < 0.005) with ED PET versus CE CT at the arterial phase and similar between the methods at the venous phase. In liver imaging, ED PET generates greater lesional-parenchymal contrast during the arterial phase than does CE CT; these observations should be formally, prospectively evaluated. (author)

  17. CT colonography: Diagnostic role of contrast enhancement of benign polyps and colorectal carcinoma

    International Nuclear Information System (INIS)

    Stoinova, V.; Nedevska, M.

    2006-01-01

    Full text: The aim of this study was to compare pre- and postcontrast CT attenuation values of benign colorectal polyps and carcinoma lesions detected by CT colonography, and to investigate whether contrast enhancement of these lesions can be potentially used for differentiation from residual fluid and feces. We retrospectively reviewed CT colonographic dataset of 120 patients. 35 benign polyps and 22 colorectal carcinomas were included in our study. All lesions were confirmed by colonoscopic biopsy or surgery. The difference in attenuation value between precontrast and postcontrast studies of polyps was statistically significant; the same was true for colorectal cancers. In the precontrast phase no statistically significant difference was observed between stool, polyps and cancers. The mean attenuation value of solid fecal residuals was 37 HU before and after contrast enhancement. Residual fluid do not take up contrast and the density does not change in the contrast-enhanced phase. The difference between postcontrast density of polyps and cancers with respect to density of stools and residual fluid was significant. The use of contrast medium could be helpful in CT colonography for discriminating polypoid benign lesions and colorectal cancer from fecal and fluid residuals

  18. Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification

    International Nuclear Information System (INIS)

    Heussel, C.P.; Kappes, J.; Hantusch, R.; Hartlieb, S.; Weinheimer, O.; Kauczor, H.-U.; Eberhardt, R.

    2010-01-01

    Systemic, interventional and surgical treatments have gone new ways in treatment of emphysema. For longitudinal therapy monitoring and as end-points for clinical trials, quantification of the disease is necessary. Sensitive, easy to measure, as well as stable and reproducible parameters have to be characterized. One parameter that might affect emphysema quantification is IV contrast enhancement, which might also be indicated. Whether or not the contrast enhanced scan is also suited for emphysema quantification or an additional scan is necessary, a retrospective analysis of 12 adult patients undergoing clinically indicated both, a non-enhanced and enhanced thin section MSCT within a week (median 0 days, range 0-4 days) was done. The in-house YACTA software was used for automatic quantification of lung and emphysema volume, emphysema index, mean lung density, and 5th, 10th, 15th percentile. After IV contrast administration, the median CT derived lung volume decreased mild by 1.1%, while median emphysema volume decreased by relevant 11%. This results in a decrease of median emphysema index by 9%. The median lung density (15th percentile) increased after contrast application by 18 HU (9 HU). CT quantification delivers emphysema values that are clearly affected by IV contrast application. The detected changes after contrast application show the results of higher density in the lung parenchyma. Therefore the amount of quantified emphysema is reduced and the lung density increased after contrast enhancement. In longitudinal analyses, non-enhanced scans should be the reference, while enhanced scans cannot be used.

  19. Diagnostic performance of Contrast-enhanced CT in Pyrrolizidine Alkaloids-induced Hepatic Sinusoidal Obstructive Syndrome

    Science.gov (United States)

    Kan, Xuefeng; Ye, Jin; Rong, Xinxin; Lu, Zhiwen; Li, Xin; Wang, Yong; Yang, Ling; Xu, Keshu; Song, Yuhu; Hou, Xiaohua

    2016-01-01

    Hepatic sinusoidal obstruction syndrome (HSOS) can be caused by pyrrolizidine alkaloids(PAs)-containing herbals. Since PAs exposure is obscure and clinical presentation of HSOS is unspecific, it is challenge to establish the diagnosis of PAs-induced HSOS. Gynura segetum is one of the most wide-use herbals containing PAs. The aim of our study is to describe the features of contrast-enhanced computed tomography (CT) in gynura segetum-induced HSOS, and then determine diagnostic performance of radiological signs. We retrospectively analyzed medical records and CT images of HSOS patients (71 cases) and the controls (222 cases) enrolled from January 1, 2008, to Oct 31, 2015. The common findings of contrast CT in PAs-induced HSOS included: ascites (100%), hepatomegaly (78.87%), gallbladder wall thickening (86.96%), pleural effusion (70.42%), hepatic vein narrowing (87.32%), patchy liver enhancement (92.96%), and heterogeneous hypoattenuation (100%); of these signs, patchy enhancement and heterogeneous hypoattenuation were valuable features. Then, the result of diagnostic performance demonstrated that contrast CT possessed better performance in diagnosing PAs-induced HSOS compared with various parameters of Seattle criteria. In conclusion, the patients with PAs-induced HSOS display distinct radiologic features at CT-scan, which reveals that contrast-enhanced CT provides an effective noninvasive method for diagnosing PAs-induced HSOS. PMID:27897243

  20. Semi-quantitative assessment of tricuspid regurgitation on contrast-enhanced multidetector CT

    International Nuclear Information System (INIS)

    Groves, A.M.; Win, T.; Charman, S.C.; Wisbey, C.; Pepke-Zaba, J.; Coulden, R.A.

    2004-01-01

    AIM: To assess whether the early regurgitation of intravenous contrast medium into the inferior vena cava (IVC) and/or hepatic veins on computed tomography (CT), indicates tricuspid regurgitation (TR), and if so, whether it be used to grade severity. MATERIALS AND METHODS: We identified 86 consecutive patients that had been investigated for possible pulmonary endarterectomy at Papworth Hospital. From these, 61 patients were selected in whom CT, transthoracic echocardiography, and right heart catheterization (RHC) had been performed within 6 weeks. Using an arbitrary visual scale, the degree of TR assessed by intravenous contrast-enhanced CT was compared with echocardiography. Results were analysed using a kappa weighted statistical test. In addition, CT and echocardiographic assessments of TR severity were correlated with pulmonary artery pressure measurements obtained by RHC (Spearman's rank correlation coefficient). RESULTS: CT assessment of TR had a sensitivity of 90.4% and a specificity of 100% in detecting echocardiographic TR. For TR graded as more than trivial by echocardiography, sensitivity of CT was 100%. With respect to RHC data, the correlation between severity assessment of TR between CT and echocardiography using the Kappa weighted coefficient was 0.56 (moderately good agreement). With respect to RHC data, the correlation between mean pulmonary pressure and TR grading on CT and echocardiography was r=0.685 (p<0.001) and r=0.727 (p<0.001), respectively. CONCLUSION: Early opacification of the IVC or hepatic veins on first-pass contrast-enhanced CT almost invariably indicates TR. There is moderately good agreement between CT and echocardiographic assessment of the severity of TR. Both CT and echocardiographic grading of TR correlate well with RHC measurements of pulmonary artery pressure

  1. Experience with contrast-enhanced CT in delayed traumatic intracerebral hematoma

    International Nuclear Information System (INIS)

    Kobayashi, Shiro; Nakazawa, Shozo; Yokota, Hiroyuki; Isayama, Kazuo; Yajima, Kouzo; Otsuka, Toshibumi

    1984-01-01

    During the four-and-a-half-year period from April, 1976, to September, 1980, out of 257 patients with severe head injuries graded 8 or less by the Glasgow Coma Scale in the Department of Neurosurgery and Critical Care Medicine of the Nippon Medical School, Tokyo, Japan, 33 cases showed the development of delayed traumatic intracerebral hematoma (DTICH) upon the serial computerized tomography (CT). Contrast-enhanced CT was performed in 20 cases of the 33 patients demonstrating DTICH. Among these, 8 cases (40%) indicated the development of DTICH in the lesions of cerebral contusion (a salt-and-pepper appearance in the initial plain CT) which showed a remarkable enhancement, sustaining the extravasation of the contrast medium into the contused brain tissue. The authors discuss the pathogenesis of DTICH and suggest that vasoparalysis in the cerebral contusion might be a factor in the development of DTICH in patients with servere head injuries. (author)

  2. Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

    International Nuclear Information System (INIS)

    Jensen, Nikolaj K. G.; Stewart, Errol; Lock, Michael; Fisher, Barbara; Kozak, Roman; Chen, Jeff; Lee, Ting-Yim; Wong, Eugene

    2014-01-01

    Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT

  3. Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Nikolaj K. G., E-mail: nkyj@regionsjaelland.dk [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Stewart, Errol [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Imaging Research Lab, Robarts Research Institute, London, Ontario N6A 5B7 (Canada); Imaging Program, Lawson Health Research Institute, London, Ontario N6C 2R5 (Canada); Lock, Michael; Fisher, Barbara [Radiation Oncology, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Kozak, Roman [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Chen, Jeff [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Lee, Ting-Yim [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Imaging Research Lab, Robarts Research Institute, London, Ontario N6A 5B7 (Canada); Imaging Program, Lawson Health Research Institute, London, Ontario N6C 2R5 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Wong, Eugene [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Department of Physics and Astronomy, University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2014-05-15

    Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT.

  4. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    International Nuclear Information System (INIS)

    Kim, You Sung; Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun; Lee, Soo Rim; Hwang, Seong Su; Lim, Yeon Soo; Park, Jeong Mi

    2017-01-01

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT

  5. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Sung [Dept. of Radiology, Ilsan Paik Hospital, College of Medicine, Inje University, Goyang (Korea, Republic of); Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Lee, Soo Rim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of); Hwang, Seong Su [Dept. of Radiology, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of); Lim, Yeon Soo [Dept. of Radiology, Bucheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Bucheon (Korea, Republic of); Park, Jeong Mi [Dept. of Radiology, Yeouido St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-02-15

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT.

  6. Examination of hepatic contrast-enhanced CT monitored by Smart Prep

    International Nuclear Information System (INIS)

    Kakizaki, Dai; Saito, Kazuhiro; Sakurada, Toru; Abe, Kimihiko; Suzuki, Kenji

    1999-01-01

    The aim of the present study is to obtain the time density curves of the contrast-enhanced CT of hepatic portal vein, hepatic and splenic parenchyma, and to examine the relation with age, body weight, type of liver dysfunction. Subjects were 32 patients with liver tumors or liver diseases. For this purpose, the procedure of hepatic CT was monitored by Smart Prep and the images of whole liver was taken when the level of the contrast at the hepatic portal vein reached to the enhancement threshold. The contrast medium used was Iomeprol 300. The adverse reactions by Iomeprol 300 were mild and any treatment did not need. There was no correlation age and weight with enhancement threshold at the hepatic portal vein and peak time at the splenic parenchyma. The enhancement threshold at the hepatic portal vein was various in patients with chrrhosis and chronic hepatitis, and tended to be delayed in patients with chrrhosis. The peak time of the splenic parenchyma was up to 52 seconds in all patients with chronic hepatitis. The shortage of the enhancement threshold and the increase in blood flow at arterial early phase were observed in the patients with advanced acute hepatitis. This method should be examined more cases with various hepatic diseases. (K.H.)

  7. Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshiyuki; Tsukabe, Akio; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tanaka, Hisashi; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Yoshiya, Kazuhisa; Shimazu, Takeshi [Osaka University Graduate School of Medicine, Department of Traumatology and Acute Critical Medicine, Osaka (Japan)

    2014-04-15

    Our study aimed to elucidate the diagnostic performance of dual-energy CT (DECT) in the detection of contrast enhancement in intracranial haematomas (ICrH) with early phase dual-energy computed tomography angiography (CTA) and compare the results with those obtained by delayed CT enhancement. Thirty-six patients with ICrH were retrospectively included in this study. All patients had undergone single-energy non-contrast CT and contrast-enhanced dual-source DECT. DECT images were post-processed with commercial software, followed by obtaining iodine images and virtual non-contrast images and generating combined images that created the impression of 120-kVp images. Two neuroradiologists, blinded to the patients' data, reviewed two reading sessions: session A (non-contrast CT and combined CT) and session B (non-contrast CT, combined CT, and iodine images) for detection of contrast enhancement in the haematomas. Contrast leakage or enhancement was detected in 23 (57.5 %) out of 40 haemorrhagic lesions in 36 patients on delayed CT. Three enhanced lesions were depicted only in the DECT iodine images. The sensitivity, specificity, positive predictive value, and negative predictive value of session A were 82.6, 94.1, 95.0, and 80.0 %, respectively, and those of session B were 95.7, 94.1, 95.7, and 94.1 %, respectively. DECT emphasised the iodine enhancement and facilitated the detection of contrast enhancement or leakage. (orig.)

  8. Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage.

    Science.gov (United States)

    Watanabe, Yoshiyuki; Tsukabe, Akio; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tanaka, Hisashi; Yoshiya, Kazuhisa; Shimazu, Takeshi; Tomiyama, Noriyuki

    2014-04-01

    Our study aimed to elucidate the diagnostic performance of dual-energy CT (DECT) in the detection of contrast enhancement in intracranial haematomas (ICrH) with early phase dual-energy computed tomography angiography (CTA) and compare the results with those obtained by delayed CT enhancement. Thirty-six patients with ICrH were retrospectively included in this study. All patients had undergone single-energy non-contrast CT and contrast-enhanced dual-source DECT. DECT images were post-processed with commercial software, followed by obtaining iodine images and virtual non-contrast images and generating combined images that created the impression of 120-kVp images. Two neuroradiologists, blinded to the patients' data, reviewed two reading sessions: session A (non-contrast CT and combined CT) and session B (non-contrast CT, combined CT, and iodine images) for detection of contrast enhancement in the haematomas. Contrast leakage or enhancement was detected in 23 (57.5 %) out of 40 haemorrhagic lesions in 36 patients on delayed CT. Three enhanced lesions were depicted only in the DECT iodine images. The sensitivity, specificity, positive predictive value, and negative predictive value of session A were 82.6, 94.1, 95.0, and 80.0 %, respectively, and those of session B were 95.7, 94.1, 95.7, and 94.1 %, respectively. DECT emphasised the iodine enhancement and facilitated the detection of contrast enhancement or leakage.

  9. Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage

    International Nuclear Information System (INIS)

    Watanabe, Yoshiyuki; Tsukabe, Akio; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tanaka, Hisashi; Tomiyama, Noriyuki; Yoshiya, Kazuhisa; Shimazu, Takeshi

    2014-01-01

    Our study aimed to elucidate the diagnostic performance of dual-energy CT (DECT) in the detection of contrast enhancement in intracranial haematomas (ICrH) with early phase dual-energy computed tomography angiography (CTA) and compare the results with those obtained by delayed CT enhancement. Thirty-six patients with ICrH were retrospectively included in this study. All patients had undergone single-energy non-contrast CT and contrast-enhanced dual-source DECT. DECT images were post-processed with commercial software, followed by obtaining iodine images and virtual non-contrast images and generating combined images that created the impression of 120-kVp images. Two neuroradiologists, blinded to the patients' data, reviewed two reading sessions: session A (non-contrast CT and combined CT) and session B (non-contrast CT, combined CT, and iodine images) for detection of contrast enhancement in the haematomas. Contrast leakage or enhancement was detected in 23 (57.5 %) out of 40 haemorrhagic lesions in 36 patients on delayed CT. Three enhanced lesions were depicted only in the DECT iodine images. The sensitivity, specificity, positive predictive value, and negative predictive value of session A were 82.6, 94.1, 95.0, and 80.0 %, respectively, and those of session B were 95.7, 94.1, 95.7, and 94.1 %, respectively. DECT emphasised the iodine enhancement and facilitated the detection of contrast enhancement or leakage. (orig.)

  10. Contrast material-enhanced CT of the abdomen

    International Nuclear Information System (INIS)

    Fishman, E.K.; Kuhlman, J.E.; Garrity, M.; Paris, D.A.

    1988-01-01

    A randomized double-blind comparison of a nonionic contrast agent (Omnipaque) and an ionic contrast agent (Hypaque) was performed to determine any difference between the two agents in the quality and performance of computed body tomography (CT). A total of 40 patient studies were performed on a state-of-the-art CT scanner with similar scanning techniques. The contrast agent was administered intravenously as a rapid infusion in all cases. The image quality of the abdominal CT scans was good to excellent in all cases. There was no difference between the ionic and nonionic agents in terms of study quality. The 20 patients who received nonionic contrast agents had no major or minor reactions. Five of the 20 patients receiving the ionic contrast agent had a total of ten adverse reactions, including nausea and vomiting, nasal congestion, sneezing, and urticaria. The authors conclude that nonionic contrast agents provide high-quality CT scans equal to those provided by ionic agents and also result in fewer reactions and less discomfort

  11. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is an x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  12. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  13. Renal streaky artifact during contrast-enhanced abdominal and pelvic CT: Comparison of high versus low osmolality contrast media

    International Nuclear Information System (INIS)

    Kim, Dae Hong; Kim, Jong Chul; Lee, Chung Keun; Shin, Kyoung Suk

    1994-01-01

    Introduction of low osmolality contrast agent(LOCA) has allowed safer, more comfortable contrast-enhanced CT examination, but there has been significant increase in image degradation when evaluating the kidneys due to streaky artifact. The authors reviewed findings of contrast- enhanced abdominal and pelvic computed tomography(CT) to know the difference of renal streaky artifact between a high osmolality contrast agent (HOCA) and LOCA. This study included two hundred contrast-enhanced CT in 200 patients, 100 performed with HOCA(meglumine ioglicate, 150 ml) and 100 performed with LOCA (iopromide,150 ml). The severity of renal streaky artifact was compared between HOCA and LOCA groups. Of the scans performed with HOCA, 40 had no artifact, 52 had grade I artifact, 6 had grade II artifact, and 2 had grade III artifact. Of the scans preformed with LOCA, 23 had no artifact, 44 had grade I artifact, 29 had grade II artifact, and 4 had grade III artifact. There was significant difference in the degree of the streaky artifact depending upon the osmolality of the contrast media used(by χ 2 -test, P=.0001). The results of this study revealed a statistically significant increased incidence of artifacts and distortions of renal image with LOCA when compared with HOCA

  14. Pathologic contrast enhancement of cerebral lesions: A comparative study using stereotactic CT, stereotactic MR imaging, and stereotactic biopsy

    International Nuclear Information System (INIS)

    Earnest, F. IV; Kelly, P.J.; Scheithauer, B.; Kall, B.; Cascino, T.L.; Ehman, R.L.; Forbes, G.

    1986-01-01

    The author compared the pattern and degree of Gd-DTPA dimeglumine contrast enhancement demonstrated on stereotactic MR images with that seen on stereotactic CT images obtained after conventional iodinated contrast agent enhancement and with histopathologic findings on sequential stereotactic brain biopsies. Stereotactic biopsies of the areas that enhanced on CT or MR imaging revealed tumor tissue with neovascularity. Tumor tissue with no or mild neovascularity did not enhance with contrast agent administration. Isolated tumor cells were frequently found beyond the margins of some primary brain neoplasms defined by contrast agent-enhanced MR imaging and CT. The histopathologic findings associated with pathologic contrast agent enhancement are presented

  15. Multimodality functional imaging of spontaneous canine tumors using 64CU-ATSM and 18FDG PET/CT and dynamic contrast enhanced perfusion CT

    DEFF Research Database (Denmark)

    Hansen, Anders E; Kristensen, Annemarie T; Law, Ian

    2012-01-01

    To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated.......To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated....

  16. Diagnostic value of contrast-enhanced dynamic CT in predicting the malignancy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Song, Koun Sik; Lee, Eun Hye; Kim, Ji Hoon; Lee, Jin Seong; Lim, Tae Hwan

    1997-01-01

    To determine whether the maximal enhancement time in dynamic CT is different between benign and malignant solitary pulmonary nodules (SPN)s, and to evaluate the value of densitometry on dynamic CT in predicting the malignancy of SPN. Fifty-six patients with SPN of less than 4cm in diameter as seen on chest radiograph and SPN without benign pattern of calcification or fat, as seen on pre-enhance-ment spiral CT scans were included in this study. SPN with small cavitation sufficient to measure CT density, were also included. Thirty-four SPNs were diagnosed pathologically or radiologically as 20 malignant nodules and 14 benign nodules. Dynamic CT was performed by two techniques after injection of 50ml of nonionic contrast media at the rate of 2ml/sec. In 28 patients, incremental dynamic CT was performed before and of 15 seconds, 1 minute, 2 minutes, 3 minutes, and 4 minutes after injection of contrast media during shallow respiration. In 28 patients, double spiral CT was performed 2 minutes and 3 minutes after injection of contrast media during single breath hold. CT readings were taken at the central portion of SPNs, with a circular region of interest. The degree and time of maximal enhancement were recorded. In dynamic CT the maximal enhancement time of SPNs was not significantly different between malignant (2.73±1.27 minute) and benign nodules (2.56±1.24 minute). The enhancement of malignant nodules was significantly greater (21.42±12.17 HU) than of benign nodules (5.15±5.25 HU) (p<.0001). In dynamic CT of SPNs, there is no difference in maximal enhancement time between benign and malignant nodules;enhancement of the latter is significantly greater than that of the former. Maximal enhancement greater than 15 HU can be a good predictor of malignancy of SPNs

  17. Histopathologic diversity of gastric cancers: Relationship between enhancement pattern on dynamic contrast-enhanced CT and histological type.

    Science.gov (United States)

    Tsurumaru, Daisuke; Miyasaka, Mitsutoshi; Muraki, Toshio; Nishie, Akihiro; Asayama, Yoshiki; Oki, Eiji; Oda, Yoshinao; Honda, Hiroshi

    2017-12-01

    To evaluate the diagnostic value of contrast-enhanced computed tomography gastrography (CE-CTG) to predict the histological type of gastric cancer. We analyzed 47 consecutive patients with resectable advanced gastric cancer preoperatively evaluated by multiphasic dynamic contrast-enhanced CT. Two radiologists independently reviewed the CT images and they determined the peak enhancement phase, and then measured the CT attenuation value of the gastric lesion for each phase. The histological types of gastric cancers were assigned to three groups as differentiated-type, undifferentiated-type, and mixed-type. We compared the peak enhancement phase of the three types and compared the CT attenuation values in each phase. The peak enhancement was significantly different between the three types of gastric cancers for both readers (reader 1, p=0.001; reader 2, p=0.009); most of the undifferentiated types had peak enhancement in the delayed phase. The CT attenuation values of undifferentiated type were significantly higher than those of differentiated or mixed type in the delayed phase according to both readers (reader 1, p=0.002; reader 2, p=0.004). CE-CTG could provide helpful information in diagnosing the histological type of gastric cancers preoperatively. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Ring-enhancement pattern on contrast-enhanced CT predicts adenosquamous carcinoma of the pancreas: a matched case-control study.

    Science.gov (United States)

    Imaoka, Hiroshi; Shimizu, Yasuhiro; Mizuno, Nobumasa; Hara, Kazuo; Hijioka, Susumu; Tajika, Masahiro; Tanaka, Tsutomu; Ishihara, Makoto; Ogura, Takeshi; Obayashi, Tomohiko; Shinagawa, Akihide; Sakaguchi, Masafumi; Yamaura, Hidekazu; Kato, Mina; Niwa, Yasumasa; Yamao, Kenji

    2014-01-01

    Adenosquamous carcinoma of the pancreas (ASC) is a rare malignant neoplasm of the pancreas, exhibiting both glandular and squamous differentiation. However, little is known about its imaging features. This study examined the imaging features of pancreatic ASC. We evaluated images of contrast-enhanced computed tomography (CT) and endoscopic ultrasonography (EUS). As controls, solid pancreatic neoplasms matched in a 2:1 ratio to ASC cases for age, sex and tumor location were also evaluated. Twenty-three ASC cases were examined, and 46 solid pancreatic neoplasms (43 pancreatic ductal adenocarcinomas, two pancreatic neuroendocrine tumors and one acinar cell carcinoma) were matched as controls. Univariate analysis demonstrated significant differences in the outline and vascularity of tumors on contrast-enhanced CT in the ASC and control groups (P outline, cystic changes, and the ring-enhancement pattern on contrast-enhanced CT were seen to have significant predictive powers by stepwise forward logistic regression analysis (P = 0.044, P = 0.010, and P = 0.001, respectively). Of the three, the ring-enhancement pattern was the most useful, and its predictive diagnostic sensitivity, specificity, positive predictive value and negative predictive value for diagnosis of ASC were 65.2%, 89.6%, 75.0% and 84.3%, respectively. These results demonstrate that presence of the ring-enhancement pattern on contrast-enhanced CT is the most useful predictive factor for ASC. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  19. CT enhancement of acute cerebral infarction following long-term continuous contrast infusion

    International Nuclear Information System (INIS)

    Ito, Umeo; Seida, Mitsuru; Tomida, Shuichi; Inaba, Yutaka.

    1985-01-01

    In this experimental study, we employed a long-term (3 hours) continuous-drip infusion of the contrast medium (200 ml of meglumine amidtrizoate) rather than the conventional bolus injection. On admission, four-vessel angiography was performed on all 14 patients. Within 3 days after the onset of the disease, CT scan was carried out repeatedly just prior to contrast infusion, immediately after the end of the continuous-contrast infusion, and additionally, in 4 cases, 3 hours after the end of the contrast infusion. The Haunsfield number was calculated in 3 regions of interest (Radius 5) in the infarction. Positive enhancement was observed in 10 out of the 14 patients (71 %). Among them, 4 out of 5 patients in whom no vascular obstraction on angiography, but marked low-density areas with a mass effect on CT were observed, showed moderate to marked enhancement. In these 4 patients, a temporary cerebral ischemia due to vascular embolization was considered. From the other 4 patients in whom the additional CT scan was performed 3 hours after the end of the contrast infusion, a blood sample was obtained at each of the 3 CT scannings. The iodine concentrations of the blood samples were measured, and their Haunsfield numbers were calculated in the water phantom. The above two parameters were well correlated in a linear function. Among the 4 patients, Gado's tissue-blood ratio (the Haunsfield number of the CT lesion is divided by that of the blood sample) was more than 17.2 % immediately after, and more than 54.7 % 3 hours after, the contrast infusion. Thus, we could conclude that the break-down of the BBB which was demonstrated by a long-term high-blood-concentration level of the contrast medium is an earlier event in human cerebral infarction than is usually accepted. The findings are compatible with our results in animal experiments. (author)

  20. Comparison of neuroendocrine tumor detection and characterization using DOTATOC-PET in correlation with contrast enhanced CT and delayed contrast enhanced MRI

    International Nuclear Information System (INIS)

    Giesel, F.L.; Kratochwil, C.; Mehndiratta, A.; Wulfert, S.; Moltz, J.H.; Zechmann, C.M.; Kauczor, H.U.; Haberkorn, U.; Ley, S.

    2012-01-01

    Purpose: We evaluated the rate of successful characterization of gastroenteropancreatic neuroendocrine tumors (NETs) present with an increased somatostatin receptor, comparing CE-CT with CE-MRI, each in correlation with DOTATOC-PET. Methods and materials: 8 patients with GEP-NET were imaged using CE-MRI (Gd-EOB-DTPA), CE-CT (Imeron 400) and DOTATOC-PET. Contrast-enhancement of normal liver-tissue and metastasis was quantified with ROI-technique. Tumor delineation was assessed with visual-score in blind-read-analysis by two experienced radiologists. Results: Out of 40 liver metastases in patients with NETs, all were detected by CE-MRI and the lesion extent could be adequately assessed, whereas CT failed to detect 20% of all metastases. The blind-read-score of CT in arterial and portal phase was median −0.65 and −1.4, respectively, and 2.7 for delayed-MRI. The quantitative ROI-analysis presented an improved contrast-enhancement-ratio with a median of 1.2, 1.6 and 3.3 for CE-CT arterial, portal-phase and delayed-MRI respectively. Conclusion: Late CE-MRI was superior to CE-CT in providing additionally morphologic characterization and exact lesion extension of hepatic metastases from neuroendocrine tumor detected with DOTATOC-PET. Therefore, late enhanced Gd-EOB-DTPA-MRI seems to be the adequate imaging modality for combination with DOTATOC-PET to provide complementary (macroscopic and molecular) tumor characterization in hepatic metastasized NETs

  1. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  2. Contrast-enhanced CT and MRI findings of atypical hepatic Echinococcus alveolarisinfestation

    International Nuclear Information System (INIS)

    Etlik, Oemer; Arslan, Halil; Harman, Mustafa; Temizoez, Osman; Bay, Ali; Koesem, Mustafa; Dogan, Ekrem

    2005-01-01

    Diagnosis of liver infestation by Echinococcus alveolaris(EA) is based on serological and radiological findings. In this report, we present a 15-year-old girl with atypical hepatic EA infestation showing central punctate calcifications and contrast enhancement on the portal and late phases of CT and MRI. CT showed a hypodense mass involving more than half of the liver with prominent central calcifications. MRI revealed hypointense signal of the infiltrative mass on both T1- and T2-weighted images. Contrast enhancement is a unique finding in hepatic EA infestation that may cause difficulties with diagnosis. MRI may provide invaluable information in the diagnosis of EA infestation of the liver, either by disclosing the infiltrative pattern of infestation without significant effect to vascular structures, or by the signal characteristics. (orig.)

  3. Contrast-enhanced CT and MRI findings of atypical hepatic Echinococcus alveolarisinfestation

    Energy Technology Data Exchange (ETDEWEB)

    Etlik, Oemer; Arslan, Halil; Harman, Mustafa; Temizoez, Osman [Yuzuncu Yil University Faculty of Medicine, Department of Radiology, Van (Turkey); Bay, Ali [Yuzuncu Yil University Faculty of Medicine, Department of Paediatrics, Van (Turkey); Koesem, Mustafa [Yuzuncu Yil University Faculty of Medicine, Department of Pathology, Van (Turkey); Dogan, Ekrem [Yuzuncu Yil University Faculty of Medicine, Department of Internal Medicine, Van (Turkey)

    2005-05-01

    Diagnosis of liver infestation by Echinococcus alveolaris(EA) is based on serological and radiological findings. In this report, we present a 15-year-old girl with atypical hepatic EA infestation showing central punctate calcifications and contrast enhancement on the portal and late phases of CT and MRI. CT showed a hypodense mass involving more than half of the liver with prominent central calcifications. MRI revealed hypointense signal of the infiltrative mass on both T1- and T2-weighted images. Contrast enhancement is a unique finding in hepatic EA infestation that may cause difficulties with diagnosis. MRI may provide invaluable information in the diagnosis of EA infestation of the liver, either by disclosing the infiltrative pattern of infestation without significant effect to vascular structures, or by the signal characteristics. (orig.)

  4. Invaded depth of extrahepatic bile duct cancer diagnosed on angiographic CT during late contrast enhancement

    International Nuclear Information System (INIS)

    Kikuyama, Masataka; Sasada, Yuzo; Koide, Shigeki; Hirai, Ritsuko; Oota, Yuji

    2006-01-01

    Thirteen patients with extrahepatic bile duct cancer were evaluated for enhancement pattern and tumor feature during late contrast enhancement on angiographic CT (AG-CT), performed before surgery. Eleven patients with late contrast enhancement had advanced cancers with invasion over the subserosal layer. Eight of these patients whose cancer had an irregular outer layer had invasion over the serosal layer (≥panc 1 b, General Rules for Surgical and Pathological Studies on Cancer of the Biliary Tract, Japanese Society of Biliary Surgery). Seven of the 13 patients had intra-pancreatic bile duct cancer. Among them, five had an irregular outer layer of the intra-pancreatic bile duct cancer; one of three with a wall thickness under 5 mm on AG-CT had panc 1 b invasion, and the other two had panc 2 (General Rules for Surgical and Pathological Studies on Cancer of the Biliary Tract, Japanese Society of Biliary Surgery) invasion. Two with a wall thickness over 5 mm on AG-CT had panc 2 invasion. These results suggest that late contrast enhancement on AG-CT is effective for diagnosing the depth of tumor invasion of the bile duct. (author)

  5. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    International Nuclear Information System (INIS)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah

    2014-01-01

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after 18 F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced PET/CT

  6. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced

  7. Iohexol for contrast enhancement of bowel in pediatric abdominal CT

    International Nuclear Information System (INIS)

    Smevik, B.; Westvik, J.

    1990-01-01

    Abdominal CT scans from 160 examinations performed on pediatric patients using iohexol 2 percent as contrast medium for bowel enhancement were evaluated retrospectively. When diluted with a beverage of the child's choice, iohexol has a neutral taste and cannot be detected, and 139 out of 142 patients drank the full amount of dilute contrast offered to them. The enhancement of bowel in the area of interest was graded as good (58%), reasonable (23%), or poor (19%). The contrast medium was prepared from leftovers from our angiocardiography studies. We conclude that the use of water-soluble contrast medium in a low concentration is a safe and cost-effective way of facilitating ingesion of sufficient amounts of the medium in oncologic pediatric patients undergoing cytotoxic and/or radiation treatment. (orig.)

  8. Osteoblastic Metastases Mimickers on Contrast Enhanced CT

    Directory of Open Access Journals (Sweden)

    Fahad Al-Lhedan

    2017-01-01

    Full Text Available Secondary osseous involvement in lymphoma is more common compared to primary bone lymphoma. The finding of osseous lesion can be incidentally discovered during the course of the disease. However, osseous metastases are infrequently silent. Detection of osseous metastases is crucial for accurate staging and optimal treatment planning of lymphoma. The aim of imaging is to identify the presence and extent of osseous disease and to assess for possible complications such as pathological fracture of the load-bearing bones and cord compression if the lesion is spinal. We are presenting two patients with treated lymphoma who were in complete remission. On routine follow-up contrast enhanced CT, there were new osteoblastic lesions in the spine worrisome for metastases. Additional studies were performed for further evaluation of both of them which did not demonstrate any corresponding suspicious osseous lesion. The patients have a prior history of chronic venous occlusive thrombosis that resulted in collaterals formation. Contrast enhancement of the vertebral body marrow secondary to collaterals formation and venous flow through the vertebral venous plexus can mimic the appearance of spinal osteoblastic metastases.

  9. Phase- and size-adjusted CT cut-off for differentiating neoplastic lesions from normal colon in contrast-enhanced CT colonography

    International Nuclear Information System (INIS)

    Luboldt, W.; Kroll, M.; Wetter, A.; Vogl, T.J.; Toussaint, T.L.; Hoepffner, N.; Holzer, K.; Kluge, A.

    2004-01-01

    A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps 0 . The slope m was determined by linear regression in the correlation (lesion ∝[xA + (1 - x)V]//H) and the Y-intercept y 0 by the minimal shift of the line needed to maximize the accuracy of separating the colonic wall from the lesions. The CT value of the lesions correlated best with the intermediate phase: 0.4A+ 0.6V(r=0.8 for polyps ≥10 mm, r=0.6 for carcinomas, r=0.4 for polyps <10 mm). The accuracy in the differentiation between lesions and normal colonic wall increased with the height implemented as divisor, reached 91% and was obtained by the dynamic cut-off described by the formula: cut-off(A,V,H) = 1.1[0.4A + 0.6V]/H + 69.8. The CT value of colonic polyps or carcinomas can be increased extrinsically by scanning in the phase in which 0.4A + 0.6V reaches its maximum. Differentiating lesions from normal colon based on CT values is possible in contrast-enhanced CTC and improves when the cut-off is adjusted (normalized) to the contrast phase and lesion size. (orig.)

  10. Acute appendicitis: sensitivity, specificity and diagnostic accuracy of thin-section contrast-enhanced CT findings

    International Nuclear Information System (INIS)

    Lee, Ji Yon; Choi, Dong Il; Park, Hae Won; Lee, Young Rae; Kook, Shin Ho; Kwang, Hyon Joo; Kim, Seung Kwon; Chung, Eun Chul

    2002-01-01

    To assess the sensitivity, specificity, and diagnostic accuracy of individual contrast-enhanced helical CT findings of acute appendicitis. We retrospectively reviewed the appendiceal helical CT scans, obtained after intravenous contrast administration (abdomen; 7-mm collimation, abdominopelvic junction; 5-mm collimation), of 50 patients with surgically proven acute appendicitis and 112 with alternative diagnoses. The following parameters were analysed by three radiologists: enlarged appendix (>6 mm in diameter), appendiceal wall thickening, appendiceal wall enhancement, no identification of the appendix, appendicolith(s), (appendiceal) intraluminal air, abscess, lymphadenopathy, terminal ileal wall thickening, focal cecal apical thickening, focal colonic wall thickening, and segmental colonic wall thickening. The CT findings of acute appendicitis that statistically distinguished it from alternative diagnoses were an enlarged appendix (sensitivity; 92%, specificity; 93%, diagnostic accuracy; 93%), appendiceal wall thickening (for these three parameters: 68%, 96% and 88%, respectively), periappendiceal fat stranding (90%, 79%, 82%), appendiceal wall enhancement (72%, 86%, 82%), appendicolith (16%, 100%, 74%), and focal cecal apical thickening (14%, 100%, 74%) (for each, p<0305). On thin-section contrast-enhanced helical CT, an enlarged appendix and periappendiceal fat stranding were found in 90% or more patients with acute appendicitis. Appendiceal wall thickening and enhancement were alearly demonstrated and significant findings for diagnosis. Less common but specific findings include appendicolith, focal cecal apical thickening and intramural air, can also help us establish a diagnosis of acute appendicitis

  11. Dynamic contrast-enhanced CT appearances of the intraductal papillary neoplasms of the bile duct

    International Nuclear Information System (INIS)

    Song Fengxiang; Zhou Jianjun; Zeng Mengsu; Zhou Kangrong; Ding Yuqin; He Deming; Shi Yuxin; Zhou Jun

    2013-01-01

    Objective: To analyze the dynamic contrast-enhanced CT appearances of intraductal papillary neoplasms of the bile duct and improve its diagnostic accuracy. Methods: Sixteen patients with intraductal papillary neoplasms of the bile duct confirmed histopathologically after surgical operation underwent dynamic contrast-enhanced multi-detector row CT scans. All imaging data were reviewed and analyzed retrospectively in correlation with surgical and pathological findings. CT values of 38 well-visualized lesions in 12 of the 16 patients at the pre-contrast phase, arterial phase and venous phase were measured. Four of the 12 patients with 17 lesions had benign tumors, and 8 of the 12 patients with 21 lesions had malignant tumors. Comparisons of CT values at the three phases between the two groups were carried out using independent sample t test. The bile CT values were measured in these 12 cases, 40 normal volunteers, and 40 subjects with bile duct stones, and the Wilcoxon signed-rank test was applied to compare the bile CT values between tumor group and the normal group and between tumor group and the bile duct stone group. The diameters of the bile ducts proximal to and distal to tumors were also measured, and Fisher exact method was carried to analyze the data. Results: Lesions located at the left lobe in 8 out of the 16 patients, the right lobe in 1 case, both the left and right lobes in 1 case, the hepatic hilum in 1 case, the common bile duct in 3 cases, and both the right lobe and the common bile duct in 2 cases. Eleven lesions appeared as papillary masses, 3 as flat masses, 1 as mixed papillary and flat masses. In one case, tumor mass could not be definitely visualized, and only dilated bile ducts and stones were demonstrated. The mean CT values of the benign tumors were (25.8 ± 8.0), (37.7 ± 10.3) and (51.7 ± 17.1) HU respectively at pre-contrast phase, arterial phase, and venous phase, and the malignant tumors were (38.4 ± 10.2), (56.6 ± 18.0) and (68.4

  12. A prolapsed cervical disc with diffuse contrast enhancement on CT

    International Nuclear Information System (INIS)

    Goto, Jun; Shinpo, Tomoyuki; Inoue, Kiyoharu; Shigeno, Taku; Ochiai, Chikayuki

    1985-01-01

    A 48-year-old woman with the C5/6 disc herniation was reported. She had noticed vague pains in the left shoulder a half year earlier. Neurological examination showed left lower cervical radicular pains and incomplete Brown-Sequard syndrome of the same side. The disc herniation was diagnosed by myelography and discography. On the CT examination, surprisingly, the prolapsed disc was homogenously enhanced after the administration of intravenous contrast medium. The vertebral angiography showed increased vascularity behind the C5/6 intervertebral space. At operation, a prolapsed nucleus pulposus with proliferated connective tissue was found and curetted. The etiology of contrast enhancement was discussed. (author)

  13. The relationship between contrast enhancement on CT and cerebral vasospasm in patient with subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Tazawa, Toshiaki; Mizukami, Masahiro; Kawase, Takeshi; Usami, Takashi; Togashi, Osamu

    1982-01-01

    Sixty patients with a single rupture of an aneurysm were subjected to study. Contrast enhanced CT (CECT) was performed by intravenous infusion of 100 ml of 60% meglumine iothalamate in 10 minutes. Post-contrast CT scans were repeated serially just after infusion, 15 minutes and 30 minutes later. Prominent increase in density in the region of the circle of Willis and its branches 30 minutes after infusion was considered as remarkable enhancement. In 17 (46%) out of 37 patients who underwent CECT within day 3, the contrast enhancement was remarkable. Transient or permanent symptomatic vasospasm occurred in 13 (76.5%) out of these 17 patients and the remaining 4 patients who underwent the operation with successful removal of subarachnoid clot within day 3 did not develop symptomatic vasospasm. Eight (67%) out of 12 patients operated within day 3, in whom post-operative CT showed incomplete removal of subarachnoid clot, developed transient or permanent symptomatic vasospasm. In only one (5%) out of 20 patients without remarkable enhancement, transient symptomatic vasospasm occurred. The abnormal contrast enhancement in the region of the circle of Willis and its branches within day 3 was closely related to the subsequent occurrence of vasospasm. Contrast enhanced CT was performed in 41 patients after day 3. There was no patient with remarkable enhancement on CECT. There was no relationship between the findings on CECT after day 3 and the occurrence of vasospasm. CECT within day 3 allows prediction of that patient destined for vasospasm and early removal of subarachnoid clot within day 3 may minimize the future development of vasospasm.(J.P.N.)

  14. The significance of delayed contrast-enhanced CT in chronic subdural hematomas

    International Nuclear Information System (INIS)

    Karasawa, Hideharu; Ohya, Shigeru; Ueno, Junji; Watanabe, Saburo; Mikabe, Toshio

    1983-01-01

    We have previously, reported our delayed contrast-enhanced CT (DCECT) findings in traumatic subdural hygromas and chronic subdural hematomas. The purpose of this report is to clarify the relationship between the contrast media within subdural hematomas and the delayed enhancement. The clinical subjects were 35 cases of traumatic subdural hematomas. DCECT examinations were performed in all cases. The concentrations of the contrast media within the hematoma were measured during the operations. DCECT showed that the density of the hematomas increased 3 to 6 hours after the injection of the contrast media. The contrast media were detected within the hematomas a few hours after the injection. The contrast media were still present 24 hours after the injection, but disappeared in 48 hours. These findings suggest that contrast media go in and then come out of the subdural hematomas and that the main factor related to delayed enhancement is the concentration of the contrast media within the hematomas. DCECT examination may be most helpful in evaluating the dynamic changes in subdural collections. (author)

  15. Adaptive radiotherapy based on contrast enhanced cone beam CT imaging

    International Nuclear Information System (INIS)

    Soevik, Aaste; Skogmo, Hege K.; Roedal, Jan; Lervaag, Christoffer; Eilertsen, Karsten; Malinen, Eirik

    2010-01-01

    Cone beam CT (CBCT) imaging has become an integral part of radiation therapy, with images typically used for offline or online patient setup corrections based on bony anatomy co-registration. Ideally, the co-registration should be based on tumor localization. However, soft tissue contrast in CBCT images may be limited. In the present work, contrast enhanced CBCT (CECBCT) images were used for tumor visualization and treatment adaptation. Material and methods. A spontaneous canine maxillary tumor was subjected to repeated cone beam CT imaging during fractionated radiotherapy (10 fractions in total). At five of the treatment fractions, CECBCT images, employing an iodinated contrast agent, were acquired, as well as pre-contrast CBCT images. The tumor was clearly visible in post-contrast minus pre-contrast subtraction images, and these contrast images were used to delineate gross tumor volumes. IMRT dose plans were subsequently generated. Four different strategies were explored: 1) fully adapted planning based on each CECBCT image series, 2) planning based on images acquired at the first treatment fraction and patient repositioning following bony anatomy co-registration, 3) as for 2), but with patient repositioning based on co-registering contrast images, and 4) a strategy with no patient repositioning or treatment adaptation. The equivalent uniform dose (EUD) and tumor control probability (TCP) calculations to estimate treatment outcome for each strategy. Results. Similar translation vectors were found when bony anatomy and contrast enhancement co-registration were compared. Strategy 1 gave EUDs closest to the prescription dose and the highest TCP. Strategies 2 and 3 gave EUDs and TCPs close to that of strategy 1, with strategy 3 being slightly better than strategy 2. Even greater benefits from strategies 1 and 3 are expected with increasing tumor movement or deformation during treatment. The non-adaptive strategy 4 was clearly inferior to all three adaptive strategies

  16. Comparison of 68Ga-DOTANOC PET/CT and contrast-enhanced CT in localisation of tumours in ectopic ACTH syndrome

    Science.gov (United States)

    Jadhav, Swati S; Lila, Anurag R; Kasaliwal, Rajeev; Khare, Shruti; Yerawar, Chaitanya G; Hira, Priya; Phadke, Uday; Shah, Hina; Lele, Vikram R; Malhotra, Gaurav; Bandgar, Tushar; Shah, Nalini S

    2016-01-01

    Background Localising ectopic adrenocorticotrophic hormone (ACTH) syndrome (EAS) tumour source is challenging. Somatostatin receptor-based PET imaging has shown promising results, but the data is limited to case reports and small case series. We reviewed here the performance of 68Ga-DOTANOC positron emission tomography (PET)/computed tomography (CT) and contrast-enhanced CT (CECT) in our cohort of 12 consecutive EAS patients. Materials and methods Retrospective data analysis of 12 consecutive patients of EAS presenting to a single tertiary care centre in a period between January 2013 and December 2014 was done. CECT and 68Ga-DOTANOC PET/CT were reported (blinded) by an experienced radiologist and a nuclear medicine physician, respectively. The performance of CECT and 68Ga-DOTANOC PET/CT was compared. Results Tumours could be localised in 11 out of 12 patients at initial presentation (overt cases), whereas in one patient, tumour remained occult. Thirteen lesions were identified in 11 patients as EAS source (true positives). CECT localised 12 out of these 13 lesions (sensitivity 92.3%) and identified five false-positive lesions (positive predictive value (PPV) 70.5%). Compared with false-positive lesions, true-positive lesions had greater mean contrast enhancement at 60s (33.2 vs 5.6 Hounsfield units (HU)). 68Ga-DOTANOC PET/CT was able to identify 9 out of 13 lesions (sensitivity 69.2%) and reported no false-positive lesions (PPV 100%). Conclusion CECT remains the first-line investigation in localisation of EAS. The contrast enhancement pattern on CECT can further aid in characterisation of the lesions. 68Ga-DOTANOC PET/CT can be added to CECT, to enhance positive prediction of the suggestive lesions. PMID:27006371

  17. Hepatic hemangioma: contrast enhancement patterns on two-phase spiral CT

    International Nuclear Information System (INIS)

    Yun, Eun Joo; Choi, Byung Ihn; Han, Joon Koo; Jang, Hyun Jung; Kim, Tae Kyoung; Kim, Ah Young; Lee, Ki Yeol

    1998-01-01

    To evaluate contrast enhancement patterns of hemangioma according to size, as seen during the arterial and portal venous phase of spiral CT. Overall, the most common enhancement pattern was peripheral high (44/82, 53.7%), during the arterial and portal venous phase. The second and third most common patterns were uniform high (11/82, 13.4%) and peripheral high-uniform high (9/82, 11.0%), also during the arterial and portal venous phase. In tumors smaller than 20 mm, low-low attenuation was seen in eight (9.8%), and iso-low attenuation in two (2.4%), during the arterial and portal venous phase, respectively. On two-phase spiral CT, the most common enhancement pattern of hemangioma was peripheral high, seen during the arterial and portal venous phase. However, a small hemangioma less than 2cm may show atypical patterns, including low and iso attenuation. (author). 23 refs., 1 tab., 4 figs

  18. Hybrid imaging with contrast enhanced CT scan: A nuclear physician's point of view

    International Nuclear Information System (INIS)

    Houzard, C.; Tychyj-Pinel, C.; Defez, D.; Valette, P.J.; Giammarile, F.; Houzard, C.; Valette, P.J.; Giammarile, F.

    2010-01-01

    The ongoing development of hybrid imaging, with physical association of CT scan and PET or SPECT scan, allows integrating morphological and functional information on a single exam. This important technological evolution changes diagnostic and therapeutic strategy in a major manner, essentially in oncology. The possibility to inject intravenously iodinated contrast media in order to enhance CT image contrast is still a controversial question in France. We present our experience in this domain by approaching technical problems and diagnostic advantages. (authors)

  19. Feasibility of contrast-enhanced cone-beam CT for target localization and treatment monitoring

    International Nuclear Information System (INIS)

    Rodal, Jan; Sovik, Aste; Skogmo, Hege Kippenes; Knudtsen, Ingerid Skjei; Malinen, Eirik

    2010-01-01

    A dog with a spontaneous maxillary tumour was given 40 Gy of fractionated radiotherapy. At five out of 10 fractions cone-beam CT (CBCT) imaging before and after administration of an iodinated contrast agent were performed. Contrast enhancement maps were overlaid on the pre-contrast CBCT images. The tumour was clearly visualized in the images thus produced.

  20. Addison's disease due to adrenal tuberculosis: Contrast-enhanced CT features and clinical duration correlation

    International Nuclear Information System (INIS)

    Guo Yingkun; Yang Zhigang; Li Yuan; Ma Ensen; Deng Yuping; Min Pengqiu; Yin Longlin; Hu Jian; Zhang Xiaochun; Chen Tianwu

    2007-01-01

    Purpose: To describe CT morphology of untreated adrenal tuberculosis during the different stages of the natural history of the disease and to evaluate the diagnostic implications of CT features. Materials and methods: We retrospectively evaluated CT features in 42 patients with documented adrenal tuberculosis for the location, size, morphology, and enhancement patterns shown on CT images. The clinical duration were correlated with the CT features. Results: Of the 42 patients with untreated adrenal tuberculosis, bilaterally enlarged adrenal glands were revealed in 38 cases (91%), unilaterally enlarged in 3 cases (7%), and normal size in 1 case (2%). Of the 41 cases (98%) with enlargement, mass-like enlargement was seen in 20 cases (49%) and enlargement with preserved contours in 21 cases (51%). Peripheral rim enhancement presented in 22 cases (52%) on contrast-enhanced CT. Non-enhanced CT scan revealed calcification in 21 cases (50%). As the duration of Addison's disease increased, the presence of calcification and contour preservation increased concomitantly (p < 0.001), whereas peripheral rim enhancement and mass-like enlargement decreased concomitantly on CT images (p < 0.001). Conclusion: CT may be helpful in diagnosing adrenal tuberculosis when clinically suspected, and CT features are correlated to the clinical duration of Addison's disease

  1. Neutral vs positive oral contrast in diagnosing acute appendicitis with contrast-enhanced CT: sensitivity, specificity, reader confidence and interpretation time

    Science.gov (United States)

    Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F

    2011-01-01

    Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365

  2. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  3. Effect of contrast enhancement and its indication for CT studies in geriatric patients

    International Nuclear Information System (INIS)

    Yamada, Hideo

    1979-01-01

    Contrast enhancement CT study after drip infusion of 3 ml of 30% Conray for 15 min proved a safe and effective procedure even in geriatric patients with an avarage age of 72.4 years old. Mild untoward effect by contrast agent was observed in 2.5% of cases examined. Contrast study was considered not necessarily to be needed in cases with cerebral infarction showing well defined low density lesion and for evaluation of degree of ventricle enlargement, cerebral atrophy and so forth. On the contrary, contrast infusion study is indispensable in such cases that show mass effect or edema which is frequently observed in fresh cerebral infarction, haemorrhagic infarction, bleeding or tumor. CT studies of the abdomen and thorax were also discussed. (author)

  4. The use of contrast-enhanced post Mortem CT in the detection of cardiovascular deaths.

    Directory of Open Access Journals (Sweden)

    Jonas Christoph Apitzsch

    Full Text Available OBJECTIVES: To evaluate the diagnostic value of contrast enhanced post mortem computed tomography (PMCT in comparison to non-enhanced post mortem CT in the detection of cardiovascular causes of death (COD. BACKGROUND: As autopsy rates decline, new methods to determine CODs are necessary. So contrast enhanced PMCT shall be evaluated in comparison to established non-enhanced PMCT in order to further improve the method. METHODS: In a prospective study, 20 corpses were examined using a 64-row multisclice CT (MSCT before and after intraarterial perfusion with a newly developed, barium-bearing contrast agent and ventilation of the lungs. The cause of death was determined in enhanced and unenhanced scans and a level of confidence (LOC was given by three experienced radiologists on a scale between 0 and 4. Results were compared to autopsy results as gold standard. Autopsy was performed blinded to PMCT-findings. RESULTS: The method allowed visualization of different types of cause of death. There was a significant improvement in LOC in enhanced scans compared to unenhanced scans as well as an improvement in the detection of COD. The cause of death could be determined in 19 out of 20 patients. CONCLUSIONS: PMCT is feasible and appears to be robust for diagnosing cardiovascular causes of death. When compared with unenhanced post-mortem CT intraarterial perfusion and pulmonary ventilation significantly improve visualization and diagnostic accuracy. These promising results warrant further studies.

  5. Comparison of Oral Contrast-Enhanced Transabdominal Ultrasound Imaging With Transverse Contrast-Enhanced Computed Tomography in Preoperative Tumor Staging of Advanced Gastric Carcinoma.

    Science.gov (United States)

    He, Xuemei; Sun, Jing; Huang, Xiaoling; Zeng, Chun; Ge, Yinggang; Zhang, Jun; Wu, Jingxian

    2017-12-01

    This study assessed the diagnostic performance of transabdominal oral contrast-enhanced ultrasound (US) imaging for preoperative tumor staging of advanced gastric carcinoma by comparing it with transverse contrast-enhanced computed tomography (CT). This retrospective study included 42 patients with advanced gastric cancer who underwent laparoscopy, radical surgery, or palliative surgery because of serious complications and had a body mass index of less than 25 kg/m 2 . A cereal-based oral contrast agent was used for transabdominal oral contrast-enhanced US. Retrospective analyses were conducted using preoperative tumor staging data acquired by either transabdominal oral contrast-enhanced US or transverse contrast-enhanced CT. Both contrast-enhanced US and contrast-enhanced CT examinations were reviewed by 2 experienced radiologists independently for preoperative tumor staging according to the seventh edition of the TNM classification. The accuracy, sensitivity, and specificity were calculated by comparing the results of contrast-enhanced US and contrast-enhanced CT with pathologic findings. The overall accuracies of the imaging modalities were compared by the McNemar test. No significant difference was noted in the overall accuracy of transabdominal oral contrast-enhanced US (86% [36 of 42]) and transverse contrast-enhanced CT (83% [35 of 42] P > .999). For stage T2 to T4 gastric cancer, the accuracies of transabdominal oral contrast-enhanced US were 88%, 86%, and 98%, respectively, and those of transverse contrast-enhanced CT were 93%, 83%, and 90%. The overall accuracy of transabdominal oral contrast-enhanced US was comparable with that of transverse contrast-enhanced CT for preoperative tumor staging of advanced gastric cancer. © 2017 by the American Institute of Ultrasound in Medicine.

  6. [Injection Pressure Evaluation of the New Venous Catheter with Side Holes for Contrast-enhanced CT/MRI].

    Science.gov (United States)

    Fukuda, Junya; Arai, Keisuke; Miyazawa, Hitomi; Kobayashi, Kyouko; Nakamura, Junpei; Suto, Takayuki; Tsushima, Yoshito

    2018-01-01

    The simulation study was conducted for the new venous catheter with side holes of contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) to evaluate the infusion pressure on four contrast media and several injection speeds. All infusion pressure of the new venous catheter with side holes were less than 15 kg/cm 2 as limitation of extension tube and also reduced the infusion pressure by 15% at the maximum compared to the catheter with single hole. The results suggest that the new venous catheter with side holes can reduce the infusion pressure by power injection of contrast-enhanced CT and MRI.

  7. The diagnostic value of contrast-enhanced CT in Acute bilateral renal cortical necrosis: a case report

    International Nuclear Information System (INIS)

    Choi, Pil Youb; Lee, Su Han; Lee, Woo Dong

    1996-01-01

    Acute renal cortical necrosis in which there is destruction of the renal cortex and sparing of the renal medulla, is a relatively rare cause of acute renal failure. A definitive diagnosis of acute renal cortical necrosis is based on renal biopsy, but on CT(computed tomography) the rather specific contrast-enhanced appearance of acute renal cortical necrosis has been described. As renal biopsy is not available, contrast-enhanced CT is a useful, noninvasive investigate modality for the early diagnosis of acute renal cortical necrosis. We report the characteristic CT findings of acute renal cortical necrosis in a patient with acute renal failure following an operation for abdominal trauma

  8. {sup 18}F-FDG PET/CT and contrast-enhanced CT findings of pulmonary cryptococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Si-yun, E-mail: wang_shuxia@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Chen, Gang, E-mail: cgggh@outlook.com [Department of Thoracic Surgery, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Luo, Dong-lan, E-mail: 695532870@qq.com [Department of Pathology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Shao, Dan, E-mail: shaodan501@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Liu, En-tao, E-mail: GDGH2015@gmail.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Sun, Taotao, E-mail: sunmoodsdaisy@bjmu.edu.cn [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Wang, Shu-Xia, E-mail: wsyggh@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China)

    2017-04-15

    Purpose: Pulmonary cryptococcosis is an uncommon cause of pulmonary nodules in non-AIDS patients. This study reports the {sup 18}F-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG PET/CT) and contrast-enhanced CT (CE-CT) findings of 42 patients with pulmonary cryptococcosis. Materials and methods: A retrospective review of the {sup 18}F-FDG PET/CT and CE-CT findings of 42 patients with histologically proven pulmonary cryptococcosis was conducted. All patients underwent PET/CT and CE-CT in the same session. The CT diagnosis was based on the location, morphological features, and enhancement of lesions. The PET/CT findings were recorded, and clinical data and surgical and histopathological findings were collected. Results: The results of the PET scans revealed that 37 (88%) of 42 patients showed higher FDG uptake, and 5 (12%) patients demonstrated lower FDG uptake than the mediastinal blood pool. The maximum standardized uptake value (SUV) of pulmonary cryptococcosis ranged from 1.4 to 13.0 (average: 5.7 ± 3.3, median 4.9). A single nodular pattern was the most prevalent pattern observed and was found in 29 (69%) patients. This pattern was followed by scattered nodular (n = 4, 10%), clustered nodular (n = 3, 7%), mass-like (n = 3, 7%), and bronchopneumonic (n = 3, 7%) patterns. The most frequent pattern of immunocompetent patients was the single nodular pattern (29 of 33, 88%). Immunocompromised patients most frequently pattern exhibited mass-like (3 of 9, 33%) and bronchopneumonic (3 of 9, 33%) patterns. Conclusion: Pulmonary cryptococcosis most commonly appears as single nodules in immunocompetent patients. Mass-like and bronchopneumonic patterns were common in immunocompromised patients. In 88% of patients, lung lesions showed high FDG uptake, thus mimicking a possible malignant condition.

  9. Primary pulmonary low-grade angiosarcoma characterized by mismatch between {sup 18}F-FDG FET and dynamic contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Eun Young; Lee, Ho Yun; Han, Joung Ho; Choi, Joon Young [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    We report a rare case of primary pulmonary low-grade angiosarcoma on dynamic contrast-enhanced CT and {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT imaging. A 38-year-old, asymptomatic woman was hospitalized because of an abnormality on chest radiography. A dynamic contrast-enhanced chest CT showed a 1.2 cm-sized irregular-margined nodule with strong and persistent enhancement in the right lower lobe. The lesion had low metabolic activity on an {sup 18}F-FDG PET/CT scan. The patient underwent a wedge resection for the lesion, and pathology revealed a primary pulmonary low-grade angiosarcoma.

  10. Usefulness of percentage enhancement washout value calculated on unenhanced, contrast-enhanced, and delayed enhanced CT in adrenal masses: adenoma versus metastasis

    International Nuclear Information System (INIS)

    Sohn, Kyung Myung; Lee, Sung Yong; Lee, Keun Ho

    2003-01-01

    To determine the usefulness of percentage enhancement washout value calculated on unenhanced, enhanced and delayed enhanced CT scans for the characterization of adrenal masses. Forty adrenal masses less than 5 cm in size were assessed using a protocol consisting of unenhanced CT, enhanced CT 60 seconds after intravenous administration of contrast material, and delayed enhanced CT at 10 minutes. The CT attenuation value of adrenal tumors was estimated on each scan, and percentage enhancement washout value was calculated as follows:[(attenuation value at enhanced CT-attenuation value at delayed CT)/ (attenuation value at enhanced CT-attenuation value at unenhanced CT)x100]. An adrenal mass was considered benign if its percentage enhancement washout value was at the threshold value, set to 60% and 50%, or higher. The accuracy of the procedure was determined by comparing its findings with the final clinical diagnosis. Twenty-nine massess were benign and 11 were malignant. The mean percentage enhancement washout value of the former was significantly higher than that of the latter (66.7% vs. 21.8%; p<0.01). All adenomas except one had a washout value of more than 50%. With a percentage washout threshold of 60%, 35 of 40 lesions were correctly characterized as benign or malignant [sensitivity 82.7% (24/29), specificity 100% (11/11), accuracy 87.5% (35/40)]; with a threshold of 50%, 39 of 40 lesions were correctly characterized [(sensitivity 96.5% (28/29), specificity 100% (11/11), accuracy 97.5% (39/40)]. Percentage enhancement washout values are useful for characterizing an adrenal mass as benign or malignant. For characterization, a threshold value of 50% was more accurate than one of 60%

  11. Initial staging of Hodgkin's disease: role of contrast-enhanced 18F FDG PET/CT.

    Science.gov (United States)

    Chiaravalloti, Agostino; Danieli, Roberta; Caracciolo, Cristiana Ragano; Travascio, Laura; Cantonetti, Maria; Gallamini, Andrea; Guazzaroni, Manlio; Orlacchio, Antonio; Simonetti, Giovanni; Schillaci, Orazio

    2014-08-01

    The objective of this study was to compare the diagnostic accuracy of positron emission tomography/low-dose computed tomography (PET/ldCT) versus the same technique implemented by contrast-enhanced computed tomography (ceCT) in staging Hodgkin's disease (HD).Forty patients (18 men and 22 women, mean age 30 ± 9.6) with biopsy-proven HD underwent a PET/ldCT study for initial staging including an unenhanced low-dose computed tomography for attenuation correction with positron emission tomography acquisition and a ceCT, performed at the end of the PET/ldCT scan, in the same exam session. A detailed datasheet was generated for illness locations for separate imaging modality comparison and then merged in order to compare the separate imaging method results (PET/ldCT and ceCT) versus merged results positron emission tomography/contrast-enhanced computed tomography (PET/ceCT). The nodal and extranodal lesions detected by each technique were then compared with follow-up data that served as the reference standard.No significant differences were found at staging between PET/ldCT and PET/ceCT in our series. One hundred and eighty four stations of nodal involvement have been found with no differences in both modalities. Extranodal involvement was identified in 26 sites by PET/ldCT and in 28 by PET/ceCT. We did not find significant differences concerning the stage (Ann Arbor).Our study shows a good concordance and conjunction between PET/ldCT and ceCT in both nodal and extranodal sites in the initial staging of HD, suggesting that PET/ldCT could suffice in most of these patients.

  12. Delayed contrast enhancement imaging of a murine model for ischemia reperfusion with carbon nanotube micro-CT.

    Directory of Open Access Journals (Sweden)

    Laurel M Burk

    Full Text Available We aim to demonstrate the application of free-breathing prospectively gated carbon nanotube (CNT micro-CT by evaluating a myocardial infarction model with a delayed contrast enhancement technique. Evaluation of murine cardiac models using micro-CT imaging has historically been limited by extreme imaging requirements. Newly-developed CNT-based x-ray sources offer precise temporal resolution, allowing elimination of physiological motion through prospective gating. Using free-breathing, cardiac-gated CNT micro-CT, a myocardial infarction model can be studied non-invasively and with high resolution. Myocardial infarction was induced in eight male C57BL/6 mice aged 8-12 weeks. The ischemia reperfusion model was achieved by surgically occluding the LAD artery for 30 minutes followed by 24 hours of reperfusion. Tail vein catheters were placed for contrast administration. Iohexol 300 mgI/mL was administered followed by images obtained in diastole. Iodinated lipid blood pool contrast agent was then administered, followed with images at systole and diastole. Respiratory and cardiac signals were monitored externally and used to gate the scans of free-breathing subjects. Seven control animals were scanned using the same imaging protocol. After imaging, the heart was harvested, cut into 1mm slices and stained with TTC. Post-processing analysis was performed using ITK-Snap and MATLAB. All animals demonstrated obvious delayed contrast enhancement in the left ventricular wall following the Iohexol injection. The blood pool contrast agent revealed significant changes in cardiac function quantified by 3-D volume ejection fractions. All subjects demonstrated areas of myocardial infarct in the LAD distribution on both TTC staining and micro-CT imaging. The CNT micro-CT system aids straightforward, free-breathing, prospectively-gated 3-D murine cardiac imaging. Delayed contrast enhancement allows identification of infarcted myocardium after a myocardial ischemic

  13. The added value of 68Ga-DOTA-TATE-PET to contrast-enhanced CT for primary site detection in CUP of neuroendocrine origin.

    Science.gov (United States)

    Kazmierczak, Philipp M; Rominger, Axel; Wenter, Vera; Spitzweg, Christine; Auernhammer, Christoph; Angele, Martin K; Rist, Carsten; Cyran, Clemens C

    2017-04-01

    To quantify the additional value of 68 Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced 68 Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and 68 Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up 68 Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. • 68 Ga-DOTA-TATE PET augments the sensitivity of contrast-enhanced CT by 50 % • 68 Ga-DOTA-TATE PET augments the accuracy of contrast-enhanced CT by 30 % • Somatostatin receptor-targeted hybrid imaging optimizes primary tumour detection in CUP-NET.

  14. Contrast enhancement of focal hepatic lesions in CT: effect of size and histology

    International Nuclear Information System (INIS)

    Burgener, F.A.; Hamlin, D.J.

    1983-01-01

    The effect of size and histology on the contrast enhancement of hepatic lesions has been analyzed in this clinical and experimental investigation yielding the following results: (1) The attenuation values of hepatic cysts in patients increase significantly and inversely with their size after contrast enhancement when the cysts measure less than twice the CT-slice thickness. This seems to be caused by partial-volume effect. (2) Experimental tumors of identical sizes and originating from the same cell line can demonstrate different contrast-enhancement patterns. (3) Peak contrast uptake in both experimental and human tumors seems to be inversely related to their size. (4) Compared to liver, contrast washout from experimental and human tumors (presumably the extravascular space) is delayed. The delay in the contrast washout from a tumor seems to correlate with tumor size. These findings suggest that in general, it is not possible to differentiate reliably among various hepatic neoplasms on the basis of their contrast enhancement patterns for the following reasons: (1) Attenuation values of small hepatic neoplasms are distorted by partial volume effect. (2) Tumors of different histologies can demonstrate the same enhancement pattern. (3) Tumors of identical histology and size can demonstrate different enhancement patterns. (4) The enhancement pattern of a tumor changes with growth or size

  15. Value of fusion of PET and MRI for staging of endometrial cancer: Comparison with 18F-FDG contrast-enhanced PET/CT and dynamic contrast-enhanced pelvic MRI

    International Nuclear Information System (INIS)

    Kitajima, Kazuhiro; Suenaga, Yuko; Ueno, Yoshiko; Kanda, Tomonori; Maeda, Tetsuo; Takahashi, Satoru; Ebina, Yasuhiko; Miyahara, Yoshiya; Yamada, Hideto; Sugimura, Kazuro

    2013-01-01

    Purpose: To investigate the diagnostic value of retrospective fusion of pelvic MRI and 18 F-fluorodeoxyglucose ( 18 F-FDG) PET images for assessment of locoregional extension and nodal staging of endometrial cancer. Materials and methods: Thirty patients with biopsy-proven endometrial cancer underwent preoperative contrast-enhanced PET/CT (PET/ceCT) and pelvic dynamic contrast-enhanced MRI for initial staging. Diagnostic performance of PET/ceCT, contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) for assessing the extent of the primary tumor (T stage) and metastasis to regional LNs (N stage) was evaluated by two experienced readers. Histopathological and follow-up imaging results were used as the gold standard. The McNemar test was employed for statistical analysis. Results: Fused PET/MRI and MRI detected 96.7% of the primary tumors, whereas PET/ceCT detected 93.3%. Accuracy for T status was 80.0% for fused PET/MRI, and MRI proved significantly more accurate than PET/ceCT, which had an accuracy of 60.0% (p = 0.041). Patient-based sensitivity, specificity and accuracy for detecting pelvic nodal metastasis were 100%, 96.3% and 96.7% for both fused PET/MRI and PET/ceCT, and 66.7%, 100% and 96.7% for MRI, respectively. These three parameters were not statistically significant (p = 1). Conclusion: Fused PET/MRI, which complements the individual advantages of MRI and PET, is a valuable technique for assessment of the primary tumor and nodal staging in patients with endometrial cancer

  16. Contrast bolus technique with rapid CT scanning

    International Nuclear Information System (INIS)

    Arnold, H.; Kuehne, D.; Rohr, W.; Heller, M.

    1981-01-01

    Twenty-three patients complying with the clinical criteria for brain death were studied by contrast-enhanced CT. In all but one, the great intracranial vessels escaped visualization; accordingly, angiography demonstrated cerebral circulatory arrest. In the remaining case, faint enhancement of the circle of Willis corresponded to angiographic demonstration of the proximal segments of cerebral arteris. Neither in normal brain nor in dead brain did slow CT scanning disclose any postcontrast increase in parenchymal attenuation. An improved technique is proposed to demonstrate the transit of the contrast bolus by rapid CT with image splitting. If cerebral blood flow is preserved, the grey and white matter will enhance significantly following administration of contrast medium. Vice versa, the absence of enhancement confirms brain death, even in instances in which the great cerebral vessels are obscured by hemorrhage or other extensive lesions. Two additional cases of brain death were evaluated by rapid CT scanning. As to brain death, the technique obviates the need for angiography or radionuclide angiography, usually applied in prospective organ donors, because its informative content is superior to that of either method. The CT technique described affords a reliable and safe diagnosis of brain death, and can be interpreted easily. (orig.)

  17. The influence of upper limb position on the effect of a contrast agent in chest CT enhancement

    International Nuclear Information System (INIS)

    Feng, Shi-Ting; Wang, Meng; Gao, Zhenhua; Tan, Guosheng; Cai, Huasong; Hu, Xiaoshu; Yang, Jianyong; Li, Zi-Ping

    2013-01-01

    Purpose: To compare the influence of two different upper limb positions on contrast agent effects in chest CT enhancement. Materials and methods: In 142 patients undergoing contrast-enhanced CT chest scanning, an indwelling venous catheter was placed in the right hand and iodinated contrast agent was injected through a high-pressure single syringe pump. The patients were divided into three age groups (<40 years; 40–60 years; and >60 years) and randomly assigned to one of two upper limb position groups: (1) supine position, both upper limbs extended and raised above head in the same horizontal plane as the body; and (2) supine position, both upper limbs raised and crossed on the forehead, with the right arm on top. Differences in mean CT values on the two sides of the thoracic inlet along the right subclavian vein were used to evaluate the effects of the contrast agent. Results: Although contrast agent effects were not significantly different among the three age groups with either limb position, there was a significant difference between patients adopting the second limb positions (Chi-square value was 5.936, P < 0.05). An excellent or good contrast agent effect was observed in 63.08% of patients assuming the first limb position, as compared with 81.69% assuming the second position. Conclusion: For contrast-enhanced CT chest scans, use of the second limb position can reduce retention of the contrast agent in the right axillary vein and the right subclavian vein outside the thorax, increase contrast agent utilization, and decrease artifacts caused by high-density, local retention of the contrast agent

  18. {sup 18}F-FDG PET/CT imaging versus dynamic contrast-enhanced CT for staging and prognosis of inflammatory breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Champion, Laurence; Edeline, Veronique; Giraudet, Anne-Laure; Wartski, Myriam [Service de Medecine Nucleaire, Saint-Cloud (France); Lerebours, Florence [Service d' Oncologie Medicale, Saint-Cloud (France); Cherel, Pascal [Institut Curie, Hopital Rene Huguenin, Service de Radiologie, Saint-Cloud (France); Bellet, Dominique [Service de Medecine Nucleaire, Saint-Cloud (France); Universite Paris Descartes, Pharmacologie Chimique et Genetique and Imagerie, Inserm U1022 CNRS UMR 8151, Faculte des sciences pharmaceutiques et biologiques, Paris (France); Alberini, Jean-Louis [Service de Medecine Nucleaire, Saint-Cloud (France); Universite Versailles Saint-Quentin, Faculte de medecine, Saint-Quentin-en-Yvelines (France)

    2013-08-15

    Inflammatory breast cancer (IBC) is the most aggressive type of breast cancer with a poor prognosis. Locoregional staging is based on dynamic contrast-enhanced (DCE) CT or MRI. The aim of this study was to compare the performances of FDG PET/CT and DCE CT in locoregional staging of IBC and to assess their respective prognostic values. The study group comprised 50 women (median age: 51 {+-} 11 years) followed in our institution for IBC who underwent FDG PET/CT and DCE CT scans (median interval 5 {+-} 9 days). CT enhancement parameters were net maximal enhancement, net early enhancement and perfusion. The PET/CT scans showed intense FDG uptake in all primary tumours. Concordance rate between PET/CT and DCE CT for breast tumour localization was 92 %. No significant correlation was found between SUVmax and CT enhancement parameters in primary tumours (p > 0.6). PET/CT and DCE CT results were poorly correlated for skin infiltration (kappa = 0.19). Ipsilateral foci of increased axillary FDG uptake were found in 47 patients (median SUV: 7.9 {+-} 5.4), whereas enlarged axillary lymph nodes were observed on DCE CT in 43 patients. Results for axillary node involvement were fairly well correlated (kappa = 0.55). Nineteen patients (38 %) were found to be metastatic on PET/CT scan with a significant shorter progression-free survival than patients without distant lesions (p = 0.01). In the primary tumour, no statistically significant difference was observed between high and moderate tumour FDG uptake on survival, using an SUVmax cut-off of 5 (p = 0.7 and 0.9), or between high and low tumour enhancement on DCE CT (p > 0.8). FDG PET/CT imaging provided additional information concerning locoregional involvement to that provided by DCE CT on and allowed detection of distant metastases in the same whole-body procedure. Tumour FDG uptake or CT enhancement parameters were not correlated and were not found to have any prognostic value. (orig.)

  19. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Saitama (Japan). Advanced Research Laboratory; Takeda, Tohoru; Itai, Yuji

    1995-12-01

    Phase-contrast X-ray computed tomography (CT) enabling the observation of biological soft tissues without contrast enhancement has been developed. The X-ray phase shift caused by an object is measured and input to a standard CT reconstruction algorithm. A thousand times increase in the image sensitivity to soft tissues is achieved compared with the conventional CT using absorption contrast. This is because the X-ray phase shift cross section of light elements is about a thousand times larger than the absorption cross section. The phase shift is detected using an X-ray interferometer and computer analyses of interference patterns. Experiments were performed using a synchrotron X-ray source. Excellent image sensitivity is demonstrated in the observation of cancerous rabbit liver. The CT images distinguish cancer lesion from normal liver tissue and, moreover, visualize the pathological condition in the lesion. Although the X-ray energy employed and the present observation area size are not suitable for medical applications as they are, phase-contrast X-ray CT is promising for investigating the internal structure of soft tissue which is almost transparent for X-rays. The high sensitivity also provides the advantage of reducing X-ray doses. (author).

  20. Prospective evaluation of MRI, 11C-acetate PET/CT and contrast-enhanced CT for staging of bladder cancer

    International Nuclear Information System (INIS)

    Vargas, H.A.; Akin, O.; Schöder, H.; Olgac, S.; Dalbagni, G.; Hricak, H.; Bochner, B.H.

    2012-01-01

    Purpose: To prospectively evaluate the diagnostic performance of magnetic resonance imaging (MRI), 11 C-acetate positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT for bladder cancer staging, using whole-mount pathologic review of radical cystectomy and pelvic lymph node specimens as the reference standard. Materials and methods: The institutional review board approved this prospective study, which was compliant with the Health Insurance Portability and Accountability Act. Written informed consent was obtained from 16 patients with histologically confirmed bladder cancer who underwent MRI, 11 C-acetate PET/CT and contrast-enhanced CT before radical cystectomy and pelvic lymph node dissection. Before imaging 4/16 patients had received intravesical Bacillus Calmette-Guérin treatment, 6 had received systemic chemotherapy, 3 had received both and 3 had received neither. Measures of diagnostic performance including accuracy, sensitivity and specificity were estimated separately for each imaging modality. Results: MRI correctly staged 56% of patients (9/16), overstaged 38% (6/16) and understaged 6% (1/16). CT correctly staged 50% of patients (8/16), overstaged 44% (7/16) and understaged 6% (1/16). In 9 patients, 11 C-acetate PET/CT showed uptake within the bladder wall; the uptake was true-positive in 7 patients and false-positive in 2 patients. Of the remaining 7 patients, 5 had true-negative and 2 had false-negative PET/CT results for cancer in the bladder wall. For all modalities, staging accuracy was reduced in patients with a history of prior intravesical and/or systemic chemotherapy. Conclusion: In staging bladder cancer, MRI, 11 C-acetate PET/CT and CT displayed similar levels of accuracy. For all modalities, a history of intravesical and/or systemic chemotherapy affected staging accuracy.

  1. Triphasic contrast enhanced CT simulation with bolus tracking for pancreas SBRT target delineation.

    Science.gov (United States)

    Godfrey, Devon J; Patel, Bhavik N; Adamson, Justus D; Subashi, Ergys; Salama, Joseph K; Palta, Manisha

    Bolus-tracked multiphasic contrast computed tomography (CT) is often used in diagnostic radiology to enhance the visibility of pancreas tumors, but is uncommon in radiation therapy pancreas CT simulation, and its impact on gross tumor volume (GTV) delineation is unknown. This study evaluates the lesion conspicuity and consistency of pancreas stereotactic body radiation therapy (SBRT) GTVs contoured in the different contrast phases of triphasic CT simulation scans. Triphasic, bolus-tracked planning CT simulation scans of 10 consecutive pancreas SBRT patients were acquired, yielding images of the pancreas during the late arterial (LA), portal venous (PV), and either the early arterial or delayed phase. GTVs were contoured on each phase by a gastrointestinal-specialized radiation oncologist and reviewed by a fellowship-trained abdominal radiologist who specializes in pancreatic imaging. The volumes of the registered GTVs, their overlap ratio, and the 3-dimensional margin expansions necessary for each GTV to fully encompass GTVs from the other phases were calculated. The contrast difference between tumor and normal pancreas was measured, and 2 radiation oncologists rank-ordered the phases according to their value for the lesion-contouring task. Tumor-to-pancreas enhancement was on average much larger for the LA and PV than the delayed phase or early arterial phases; the LA and PV phases were also consistently preferred by the radiation oncologists. Enhancement differences among the phases resulted in highly variable GTV volumes with no observed trends. Overlap ratios ranged from 18% to 75% across all 3 phases, improving to 43% to 91% when considering only the preferred LA and PV phases. GTV expansions necessary to encompass all GTVs ranged from 0.3 to 1.8 cm for all 3 phases, improving slightly to 0.1 to 1.4 cm when considering just the LA and PV phases. For pancreas SBRT, we recommend combining the GTVs from a multiphasic CT simulation with bolus-tracking, including

  2. Accuracy and role of contrast-enhanced CT in diagnosis and surgical planning in 88 soft tissue tumours of extremities

    International Nuclear Information System (INIS)

    Verga, Lucia; Robiati, Sara; De Marchi, Armanda; Martorano, Domenico; Faletti, Carlo; Brach del Prever, Elena Maria; Linari, Alessandra; Boffano, Michele; Piana, Raimondo

    2016-01-01

    Soft tissue tumours (STT) require accurate diagnosis in order to identify potential malignancies. Preoperative planning is fundamental to avoid inadequate treatments. The role of contrast-enhanced computed tomography (CT) for local staging remains incompletely assessed. Aims of the study were to evaluate CT accuracy in discriminating active from aggressive tumours compared to histology and evaluate the role of CT angiography (CTA) in surgical planning. This retrospective cohort series of 88 cases from 1200 patients (7 %) was locally studied by contrast-enhanced CT and CTA in a referral centre: 74 malignant tumours, 14 benign lesions. Contrast-enhancement patterns and relationship of the mass with major vessels and bone were compared with histology on surgically excised samples. Sensitivity, specificity, positive and negative predictive values (PPV, NPV) were evaluated in discriminating active from aggressive tumours. Sensitivity in differentiating aggressive tumours from active lesions was 89 %, specificity 84 %, PPV 90 %, NPV 82 %. The relationship between mass and major vessels/bone was fundamental for surgical strategy respectively in 40 % and in 58 % of malignant tumours. Contrast-enhanced CT and CTA are effective in differentiating aggressive masses from active lesions in soft tissue and in depicting the relationship between tumour and adjacent bones and major vessels. (orig.)

  3. SU-F-J-71: Improving CT Quality for Radiation Therapy Planning and Delivery Guidance Using a Non-Linear Contrast Enhancement Technique

    Energy Technology Data Exchange (ETDEWEB)

    Noid, G; Tai, A; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States)

    2016-06-15

    Purpose: Advanced image post-processing techniques which enhance soft-tissue contrast in CT have not been widely employed for RT planning or delivery guidance. The purpose of this work is to assess the soft-tissue contrast enhancement from non-linear contrast enhancing filters and its impact in RT. The contrast enhancement reduces patient alignment uncertainties. Methods: Non-linear contrast enhancing methods, such as Best Contrast (Siemens), amplify small differences in X-ray attenuation between two adjacent structure without significantly increasing noise. Best Contrast (BC) separates a CT into two frequency bands. The low frequency band is modified by a non-linear scaling function before recombination with the high frequency band. CT data collected using a CT-on-rails (Definition AS Open, Siemens) during daily CT-guided RT for 6 prostate cancer patients and an image quality phantom (The Phantom Laboratory) were analyzed. Images acquired with a standard protocol (120 kVp, 0.6 pitch, 18 mGy CTDIvol) were processed before comparison to the unaltered images. Contrast and noise were measured in the the phantom. Inter-observer variation was assessed by placing prostate contours on the 12 CT study sets, 6 enhanced and 6 unaltered, in a blinded study involving 8 observers. Results: The phantom data demonstrate that BC increased the contrast between the 1.0% supra-slice element and the background substrate by 46.5 HU while noise increased by only 2.3 HU. Thus the contrast to noise ratio increased from 1.28 to 6.71. Furthermore, the variation in centroid position of the prostate contours was decreased from 1.3±0.4 mm to 0.8±0.3 mm. Thus the CTV-to-PTV margin was reduced by 1.1 mm. The uncertainty in delineation of the prostate/rectum edge decreased by 0.5 mm. Conclusion: As demonstrated in phantom and patient scans the BC filter accentuates soft-tissue contrast. This enhancement leads to reduced inter-observer variation, which should improve RT planning and delivery

  4. The value of contrast-enhanced 64-row CT in differentiating benign from malignant serous ovarian neoplasms

    International Nuclear Information System (INIS)

    Dong Tianfa; Wu Meixian; Zhang Jiayun; Song Ting

    2009-01-01

    Objective: To assess the diagnostic value of contrast-enhanced 64-row CT scanning in deciding benign or malignant serous ovarian tumors. Methods: Fifty-eight cases of serous ovarian tumors proved pathologically were reviewed, including 25 malignant tumors, 25 benign, 8 borderline tumors. All patients underwent 64-row CT scanning, including plain scanning and contrast-enhance scanning. The tumors' shape, density, blood supply and enhancement features were evaluated. Results: Twenty-five cases of benign serous cystic adenoma were mostly unicameral, and showed a moderate mural enhancement only in 4 cases (16%) due to chronic pelvic infection and the others (21/25, 84%) had no of slight enhancement. Malignant tumors were cystic-solid mass with unclear margin, irregular shape and septa. Twenty-two cases of serous cystadenocarcinoma out of 25 cases (88%) appeared obvious enhancement and other 3 cases no enhancement. And 7 cases out of 8 (87.5%) borderlined serous cystadenomas showed different enhancement patterns. Conclusion: Benign ovarian serous neoplasms were mostly unicameral and no strong mural enhancement, suggesting a lack of blood supply. While, there were obvious enhancement in the ovarian serous cystadenocarcinoma and borderline serous cystadenoma with malignant potential. The 64-row CT is helpful for differentiating the nature of the serous ovarian neoplasm. (authors)

  5. Value of fusion of PET and MRI for staging of endometrial cancer: Comparison with {sup 18}F-FDG contrast-enhanced PET/CT and dynamic contrast-enhanced pelvic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Suenaga, Yuko; Ueno, Yoshiko [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Kanda, Tomonori [Department of Obsterics and Gynecology of Kobe University School of Medicine, Kobe (Japan); Department of Radiology, Hyogo Cancer Center, Hyogo (Japan); Maeda, Tetsuo; Takahashi, Satoru [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Ebina, Yasuhiko; Miyahara, Yoshiya; Yamada, Hideto [Department of Obsterics and Gynecology of Kobe University School of Medicine, Kobe (Japan); Department of Radiology, Hyogo Cancer Center, Hyogo (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University School of Medicine, Kobe (Japan)

    2013-10-01

    Purpose: To investigate the diagnostic value of retrospective fusion of pelvic MRI and {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET images for assessment of locoregional extension and nodal staging of endometrial cancer. Materials and methods: Thirty patients with biopsy-proven endometrial cancer underwent preoperative contrast-enhanced PET/CT (PET/ceCT) and pelvic dynamic contrast-enhanced MRI for initial staging. Diagnostic performance of PET/ceCT, contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) for assessing the extent of the primary tumor (T stage) and metastasis to regional LNs (N stage) was evaluated by two experienced readers. Histopathological and follow-up imaging results were used as the gold standard. The McNemar test was employed for statistical analysis. Results: Fused PET/MRI and MRI detected 96.7% of the primary tumors, whereas PET/ceCT detected 93.3%. Accuracy for T status was 80.0% for fused PET/MRI, and MRI proved significantly more accurate than PET/ceCT, which had an accuracy of 60.0% (p = 0.041). Patient-based sensitivity, specificity and accuracy for detecting pelvic nodal metastasis were 100%, 96.3% and 96.7% for both fused PET/MRI and PET/ceCT, and 66.7%, 100% and 96.7% for MRI, respectively. These three parameters were not statistically significant (p = 1). Conclusion: Fused PET/MRI, which complements the individual advantages of MRI and PET, is a valuable technique for assessment of the primary tumor and nodal staging in patients with endometrial cancer.

  6. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fukukura, Yoshihiko, E-mail: fukukura@m.kufm.kagoshima-u.ac.jp [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Takumi, Koji [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Higashi, Michiyo [Department of Human Pathology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Shinchi, Hiroyuki [Department of Surgical Oncology and Digestive Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan)

    2014-04-15

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival.

  7. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    International Nuclear Information System (INIS)

    Fukukura, Yoshihiko; Takumi, Koji; Higashi, Michiyo; Shinchi, Hiroyuki; Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro

    2014-01-01

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival

  8. Low-Dose Contrast-Enhanced Breast CT Using Spectral Shaping Filters: An Experimental Study.

    Science.gov (United States)

    Makeev, Andrey; Glick, Stephen J

    2017-12-01

    Iodinated contrast-enhanced X-ray imaging of the breast has been studied with various modalities, including full-field digital mammography (FFDM), digital breast tomosynthesis (DBT), and dedicated breast CT. Contrast imaging with breast CT has a number of advantages over FFDM and DBT, including the lack of breast compression, and generation of fully isotropic 3-D reconstructions. Nonetheless, for breast CT to be considered as a viable tool for routine clinical use, it would be desirable to reduce radiation dose. One approach for dose reduction in breast CT is spectral shaping using X-ray filters. In this paper, two high atomic number filter materials are studied, namely, gadolinium (Gd) and erbium (Er), and compared with Al and Cu filters currently used in breast CT systems. Task-based performance is assessed by imaging a cylindrical poly(methyl methacrylate) phantom with iodine inserts on a benchtop breast CT system that emulates clinical breast CT. To evaluate detectability, a channelized hoteling observer (CHO) is used with sums of Laguerre-Gauss channels. It was observed that spectral shaping using Er and Gd filters substantially increased the dose efficiency (defined as signal-to-noise ratio of the CHO divided by mean glandular dose) as compared with kilovolt peak and filter settings used in commercial and prototype breast CT systems. These experimental phantom study results are encouraging for reducing dose of breast CT, however, further evaluation involving patients is needed.

  9. Prospective evaluation of MRI, {sup 11}C-acetate PET/CT and contrast-enhanced CT for staging of bladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, H.A., E-mail: vargasah@mskcc.org [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Akin, O.; Schöder, H. [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Olgac, S. [Department of Pathology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Dalbagni, G. [Department of Surgery, Urology Service, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Hricak, H. [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Bochner, B.H. [Department of Surgery, Urology Service, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2012-12-15

    Purpose: To prospectively evaluate the diagnostic performance of magnetic resonance imaging (MRI), {sup 11}C-acetate positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT for bladder cancer staging, using whole-mount pathologic review of radical cystectomy and pelvic lymph node specimens as the reference standard. Materials and methods: The institutional review board approved this prospective study, which was compliant with the Health Insurance Portability and Accountability Act. Written informed consent was obtained from 16 patients with histologically confirmed bladder cancer who underwent MRI, {sup 11}C-acetate PET/CT and contrast-enhanced CT before radical cystectomy and pelvic lymph node dissection. Before imaging 4/16 patients had received intravesical Bacillus Calmette-Guérin treatment, 6 had received systemic chemotherapy, 3 had received both and 3 had received neither. Measures of diagnostic performance including accuracy, sensitivity and specificity were estimated separately for each imaging modality. Results: MRI correctly staged 56% of patients (9/16), overstaged 38% (6/16) and understaged 6% (1/16). CT correctly staged 50% of patients (8/16), overstaged 44% (7/16) and understaged 6% (1/16). In 9 patients, {sup 11}C-acetate PET/CT showed uptake within the bladder wall; the uptake was true-positive in 7 patients and false-positive in 2 patients. Of the remaining 7 patients, 5 had true-negative and 2 had false-negative PET/CT results for cancer in the bladder wall. For all modalities, staging accuracy was reduced in patients with a history of prior intravesical and/or systemic chemotherapy. Conclusion: In staging bladder cancer, MRI, {sup 11}C-acetate PET/CT and CT displayed similar levels of accuracy. For all modalities, a history of intravesical and/or systemic chemotherapy affected staging accuracy.

  10. Differentiation between tuberculosis and primary tumors in the adrenal gland: evaluation with contrast-enhanced CT

    International Nuclear Information System (INIS)

    Yang, Zhi-Gang; Guo, Ying-Kun; Li, Yuan; Min, Peng-Qiu; Yu, Jian-Qun; Ma, En-Sen

    2006-01-01

    The aim of the present study is to determine imaging criteria for differentiating tuberculosis from primary tumors in the adrenal gland on contrast-enhanced CT. Non-contrast and contrast-enhanced CT features in 108 patients with adrenal tuberculosis (n=34) and primary tumor (n=74) were retrospectively assessed for the location, size, calcification and enhancement patterns. The primary tumors included 41 adenomas, 11 pheochromocytomas, 4 carcinomas, 3 lymphomas, 6 myelolipomas, 6 ganglioneuromas, 2 neurilemmomas and 1 ganglioneuroblastoma. Biochemical investigation was performed for all patients. Of the tuberculosis cases, 31 (91%) invaded with bilateral involvement, while 7 (9%) of the primary tumors invaded with bilateral involvement (P<0.001). Tuberculosis often showed calcification (20 of 34; 59%), whereas primary tumors infrequently showed calcification (6 of 74; 8%; P<0.001). Low attenuation in the center with peripheral rim enhancement was more commonly seen in tuberculosis (16 of 34; 47%) than in primary tumors (7 of 74; 9%; P<0.001). In the determination of tuberculosis, the highest sensitivity (91%) and accuracy (91%) were obtained with bilateral involvement, and the highest specificity (99%) was obtained with the contour preserved. In the determination of primary tumors using a combination of having unilateral involvement and being mass-like, the outcome was a sensitivity of 91%, specificity of 94% and accuracy of 92%. CT findings can differentiate tuberculosis from a primary tumor of the adrenal glands with high sensitivity and an acceptable specificity when combined with the endocrinological examination. (orig.)

  11. The Effect of the Degree of Luminal Contrast-Enhancement on CT Measurement of Plaque Size: A Comparison with T1-weighted Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Hur, Jin; Lee, Hye Jeong; Kim, Young Jin; Choe, Kyu Ok; Kim, Tae Hoon

    2010-01-01

    We studied early and delayed contrast-enhanced CT to determine the effects of the degree of luminal enhancement on the measurement of plaque size compared to T1-weighted MRI. T1-weighted MRI and a two-phase contrast-enhanced CT was performed in 5 New Zealand white rabbits with atherosclerosis. Early-phase images were acquired during an expected peak enhancement period of the lumen; delayed-phase images were acquired 240 sec after administration of the contrast media. Anteroposterior and lateral luminal diameters (APD, LD), luminal area (LA), total vessel area (TVA), and plaque area (PA) of the aorta were measured on MRI and CT, respectively and compared to each other. A total of 78 slices of the aorta were analyzed. PA, measured on T1-weighted MR images, was significantly greater than PA for both early-phase and delayed-phase CT (p 2 (p 2 (p 2 (p = 0.159) for MRI vs. early-phase CT, MRI vs. delayed-phase CT, and early-phase CT vs. delayed-phase CT, respectively. Different luminal densities by contrast enhancement do not affect the CT measurement of plaque area for the detection of obstructive coronary artery disease

  12. Gadolinium-DTPA and gadodiamide as an alternative contrast medium for CT

    International Nuclear Information System (INIS)

    Engelbrecht, V.; Koch, J.A.; Rassek, M.; Moedder, U.

    1996-01-01

    To evaluate the effect of intravenously applied gadolinium-based contrast medium in computed tomographic (CT) studies. Serial dilutions of iohexol 300, Gd-DTPA and gadodiamide were scanned with CT in a phantom study using water filled tubes. For quantification of X-ray attenuation, the mean Hounsfield units (HU) were calculated from the CT scans. Five patients with contraindications against iodine contrast agents were examined with abdominal or thoracic CT before and after application of 0.2 mmol/kg body weight of a gadolinium-based contrast agent. In these patients attenuation values were obtained in ROI from unenhanced and enhanced CT scans. The phantom study revealed a 38,4% enhancement for Gd-DTPA and a 35.7% enhancement for gadodiamide scaled on the reference measurements with iohexol 300. Thus, 130.2 ml Gd-DTPA or 140.1 ml gadodiamide are needed to achieve the same attenuation as an i.v. injection of 50 ml iohexol 300. Consequently the corresponding dose of 1 mmol/kg body weight would exceed the manufacturer's recommended dose. In four patients with complete thoracic or abdominal CT, i.v. applied gadolinium-based contrast medium (0.2 mmol/kg) yielded no visible advantage. In these patients parenchymal enhancement did not exceed 25%. Dynamic CT of a patient with focal liver lesion revealed an arterial enhancement peak of 75%. Sufficient parenchymal enhancement in CT studies cannot be achieved with the available gadolinium-based contrast mediums. They might be helpful if only short time vascular enhancement is required. (orig.) [de

  13. Multiphasic contrast-enhanced CT and MRI findings of adult mesoblastic nephroma: A report of two cases

    Directory of Open Access Journals (Sweden)

    Yuqin Ding

    2013-01-01

    Full Text Available Mesoblastic nephroma (MN presenting in an adult is extremely rare. The computed tomography (CT and magnetic resonance imaging (MRI features of this tumor in adulthood have not been widely reported. We present two additional cases of adult MN and describe the multiphasic contrast-enhanced CT and MRI findings.

  14. How to reduce nephropathy following contrast-enhanced CT: A lesson in policy implementation

    International Nuclear Information System (INIS)

    Richenberg, J.

    2012-01-01

    In excess of 50 contrast-enhanced computed tomography (CT) examinations are typically undertaken in our tertiary hospital NHS Trust each weekday, approximately 13,000 each year. In the Department of Radiology alone, we inject more than 1300 l of iodinated contrast medium per annum. There is a real need to devise a policy to anticipate contrast medium-induced nephropathy (CIN) and minimize its effects, without disrupting the high-intensity CT service. Having written a comprehensive yet pragmatic policy to reduce the incidence of this iatrogenic condition, it seemed sensible to share it with the wider radiology community and share the experience and lessons learnt in engaging all the stakeholders, ushering in the change with as little fuss as possible. The ramifications on primary and secondary care had to be anticipated, resource implications managed, and staff trained. This review is therefore presented in four sections: framing the problem, assessing its size and nature; a succeeding section on the available guidelines and their uptake; the policy itself to reduce CIN in CT is presented in the third section; and crucially, a description of the policy introduction process in the last section.

  15. Prognostic criteria in acute pancreatitis: importance of assessment of pancreatic necrosis by contrast-enhanced CT

    International Nuclear Information System (INIS)

    Echevarria, F.; Martinez, B.; Lopez, F.; Vuelta, R.V.

    1997-01-01

    To compare the value of the clinical criteria of Ranson, the classical tomographic criteria of Balthzar and the severity of illness index according to CT in predicting the development of complications of acute pancreatitis. A retrospective study was performed in 100 patients with clinical and analytical evidence of acute pancreatitis. All patients were assessed according to Ranson score at admission and 48 hours later, and contrast-enhanced abdominal CT was carried out. The tomographic images were analyzed on the basis of the classical criteria of Balthazar and the new CT severity of illness index, which includes the assessment of pancreatic necrosis, identified as the areas of the pancreas that are not enhanced by the administration of the contrast material. These three criteria were then correlated with onset of medical and surgical implications. Our findings show that, of the three criteria analyzed, the CT severity of illness index presents the greatest specificity, sensitivity and positive and negative predictive values in the prediction of complications of acute pancreatitis. We conclude that the inclusion of pancreatic necrosis in the tomographic study improves the early assessment of the prognosis of acute pancreatitis. (Author) 20 refs

  16. Multiphase CT scanning and different intravenous contrast media concentrations in combined F-18-FDG PET/CT: Effect on quantitative and clinical assessment

    Energy Technology Data Exchange (ETDEWEB)

    Rebiere, Marilou, E-mail: Marilou.Rebiere@rwth-aachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Verburg, Frederik A., E-mail: fverburg@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Nuclear Medicine, Maastricht University Medical Center, P. Debeylaan 25, 6202 AZ Maastricht (Netherlands); Palmowski, Moritz, E-mail: mpalmowski@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Radiology, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Experimental Molecular Imaging, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Krohn, Thomas, E-mail: tkrohn@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Pietsch, Hubertus, E-mail: hubertus.pietsch@bayer.com [Contrast Media Research, Bayer Pharma AG, Muellerstr. 178, 13353 Berlin (Germany); Kuhl, Christiane K., E-mail: ckuhl@ukaachen.de [Department of Radiology, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Mottaghy, Felix M., E-mail: fmottaghy@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Nuclear Medicine, Maastricht University Medical Center, P. Debeylaan 25, 6202 AZ Maastricht (Netherlands); Behrendt, Florian F., E-mail: fbehrendt@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany)

    2012-08-15

    Purpose: To evaluate the influence of multiphase CT scanning and different intravenous contrast media on contrast enhancement, attenuation correction and image quality in combined PET/CT. Material and methods: 140 patients were prospectively enrolled for F-18-FDG-PET/CT including a low-dose unenhanced, arterial and venous contrast enhanced CT. The first (second) 70 patients, received contrast medium with 370 (300) mg iodine/ml. The iodine delivery rate (1.3 mg/s) and total iodine load (44.4 g) were identical for both groups. Contrast enhancement and maximum and mean standardized FDG uptake values (SUVmax and SUVmean) were determined for the un-enhanced, arterial and venous PET/CT at multiple anatomic sites and PET reconstructions were visually evaluated. Results: Arterial contrast enhancement was significantly higher for the 300 mg/ml contrast medium compared to 370 mg I/ml at all anatomic sites. Venous enhancement was not different between the two contrast media. SUVmean and SUVmax were significantly higher for the contrast enhanced compared to the non-enhanced PET/CT at all anatomic sites (all P < 0.001). Tracer uptake was significantly higher in the arterial than in the venous PET/CT in the arteries using both contrast media (all P < 0.001). No differences in tracer uptake were found between the contrast media (all P > 0.05). Visual assessment revealed no relevant differences between the different PET reconstructions. Conclusions: There is no relevant qualitative influence on the PET scan from the use of different intravenous contrast media in its various phases in combined multiphase PET/CT. For quantitative analysis of tracer uptake it is required to use an identical PET/CT protocol.

  17. Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT

    International Nuclear Information System (INIS)

    Driscoll, B.; Keller, H.; Coolens, C.

    2011-01-01

    Purpose: Dynamic contrast enhanced CT (DCE-CT) studies with modeling of blood flow and tissue perfusion are becoming more prevalent in the clinic, with advances in wide volume CT scanners allowing the imaging of an entire organ with sub-second image frequency and sub-millimeter accuracy. Wide-spread implementation of perfusion DCE-CT, however, is pending fundamental validation of the quantitative parameters that result from dynamic contrast imaging and perfusion modeling. Therefore, the goal of this work was to design and construct a novel dynamic flow imaging phantom capable of producing typical clinical time-attenuation curves (TACs) with the purpose of developing a framework for the quantification and validation of DCE-CT measurements and kinetic modeling under realistic flow conditions. Methods: The phantom is based on a simple two-compartment model and was printed using a 3D printer. Initial analysis of the phantom involved simple flow measurements and progressed to DCE-CT experiments in order to test the phantoms range and reproducibility. The phantom was then utilized to generate realistic input TACs. A phantom prediction model was developed to compute the input and output TACs based on a given set of five experimental (control) parameters: pump flow rate, injection pump flow rate, injection contrast concentration, and both control valve positions. The prediction model is then inversely applied to determine the control parameters necessary to generate a set of desired input and output TACs. A protocol was developed and performed using the phantom to investigate image noise, partial volume effects and CT number accuracy under realistic flow conditionsResults: This phantom and its surrounding flow system are capable of creating a wide range of physiologically relevant TACs, which are reproducible with minimal error between experiments (σ/μ 2 ) for the input function between 0.95 and 0.98, while the maximum enhancement differed by no more than 3.3%. The

  18. Benign pulmonary nodule. Morphological features and contrast enhancement evaluated with contiguous thin-section CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Hisayasu; Murata, Kiyoshi; Takahashi, Masashi; Morita, Rikushi [Shiga Univ. of Medical Science, Otsu (Japan)

    1998-10-01

    The morphological changes in 54 benign lung nodules, including 8 histologically proven nodules of tuberculoma, 10 of focal organizing pneumonia (FOP), 1 of lung abscess and 35 other benign nodules, were evaluated with contiguous thin-section (3 mm) CT. In addition, incremental dynamic studies were carried out in 25 of these nodules. The three-dimensional shapes of the nodules were found to be quite varied and were classified into four types: round mass (n=18), polygonal mass with concave or straight margins (n=20), oval or band-like mass extending along the bronchovascular bundle (n=7), and oval mass attached to the pleura with broad contact (n=9). Forty-two (78%) of the 54 nodules were located along the bronchovascular bundle. The maximum increments in CT values over 20 HU were observed after contrast enhancement in 18 (72%) of the 25 benign nodules, among which all tuberculomas showed little or no contrast enhancement. The number of small vessels quantified microscopically in the center of the nodules were minimal in tuberculomas with little enhancement and plentiful in lesions of FOP and abscess which showed marked enhancement. Our results suggest that the differentiation between benign and malignant pulmonary nodules is not possible simply on the basis of the degree of contrast enhancement. Therefore, morphological features and the anatomical relation to the bronchovascular bundles should also be taken into consideration in the diagnosis of pulmonary nodules. (author)

  19. Benign pulmonary nodule. Morphological features and contrast enhancement evaluated with contiguous thin-section CT

    International Nuclear Information System (INIS)

    Matsuo, Hisayasu; Murata, Kiyoshi; Takahashi, Masashi; Morita, Rikushi

    1998-01-01

    The morphological changes in 54 benign lung nodules, including 8 histologically proven nodules of tuberculoma, 10 of focal organizing pneumonia (FOP), 1 of lung abscess and 35 other benign nodules, were evaluated with contiguous thin-section (3 mm) CT. In addition, incremental dynamic studies were carried out in 25 of these nodules. The three-dimensional shapes of the nodules were found to be quite varied and were classified into four types: round mass (n=18), polygonal mass with concave or straight margins (n=20), oval or band-like mass extending along the bronchovascular bundle (n=7), and oval mass attached to the pleura with broad contact (n=9). Forty-two (78%) of the 54 nodules were located along the bronchovascular bundle. The maximum increments in CT values over 20 HU were observed after contrast enhancement in 18 (72%) of the 25 benign nodules, among which all tuberculomas showed little or no contrast enhancement. The number of small vessels quantified microscopically in the center of the nodules were minimal in tuberculomas with little enhancement and plentiful in lesions of FOP and abscess which showed marked enhancement. Our results suggest that the differentiation between benign and malignant pulmonary nodules is not possible simply on the basis of the degree of contrast enhancement. Therefore, morphological features and the anatomical relation to the bronchovascular bundles should also be taken into consideration in the diagnosis of pulmonary nodules. (author)

  20. Effects of computed tomography contrast medium factors on contrast enhancement

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi; Okuda, Itsuko

    2011-01-01

    The various nonionic iodinated contrast media used in contrast computed tomography (CT) studies differ in terms of their composition, characteristics, and iodine concentration (mgI/ml), as well as the volume injected (ml). Compared with ionic iodinated contrast media, nonionic iodinated contrast media are low-osmolar agents, with different agents having different osmotic pressures. Using a custom-made phantom incorporating a semipermeable membrane, the osmotic flow rate (hounsfield unit (HU)/s) could easily be measured based on the observed increase in CT numbers, and the relationship between the osmotic pressure and the osmotic flow rate could be obtained (r 2 =0.84). In addition, taking the effects of patient size into consideration, the levels of contrast enhancement in the abdominal aorta (AA) and inferior vena cava (IVC) were compared among four types of CT contrast medium. The results showed differences in contrast enhancement in the IVC during the equilibrium phase depending on the type of contrast medium used. It was found that the factors responsible for the differences observed in enhancement in the IVC were the osmotic flow rate and the volume of the blood flow pathways in the circulatory system. It is therefore considered that the reproducibility of contrast enhancement is likely to be reduced in the examination of parenchymal organs, in which scanning must be performed during the equilibrium phase, even if the amount of iodine injected per unit body weight (mgI/kg) is maintained at a specified level. (author)

  1. Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantoms.

    Science.gov (United States)

    Shimonobo, Toshiaki; Funama, Yoshinori; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, Kazuo

    2016-01-01

    We used pediatric and adult anthropomorphic phantoms to compare the radiation dose of low- and standard tube voltage chest and abdominal non-contrast-enhanced computed tomography (CT) scans. We also discuss the optimal low tube voltage for non-contrast-enhanced CT. Using a female adult- and three differently-sized pediatric anthropomorphic phantoms we acquired chest and abdominal non-contrast-enhanced scans on a 320-multidetector CT volume scanner. The tube voltage was set at 80-, 100-, and 120 kVp. The tube current was automatically assigned on the CT scanner in response to the set image noise level. On each phantom and at each tube voltage we measured the surface and center dose using high-sensitivity metal-oxide-semiconductor field-effect transistor detectors. The mean surface dose of chest and abdominal CT scans in 5-year olds was 4.4 and 5.3 mGy at 80 kVp, 4.5 and 5.4 mGy at 100 kV, and 4.0 and 5.0 mGy at 120 kVp, respectively. These values were similar in our 3-pediatric phantoms (p > 0.05). The mean surface dose in the adult phantom increased from 14.7 to 19.4 mGy for chest- and from 18.7 to 24.8 mGy for abdominal CT as the tube voltage decreased from 120 to 80 kVp (p voltage and the low tube voltage technique can be used for non-contrast-enhanced chest- and abdominal scanning. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Utility of bolus dynamic CT for the detection of hypervascular malignant hepatic tumors. Mainly referring to the comparison with delayed phase contrast-enhanced CT

    International Nuclear Information System (INIS)

    Matsuda, Hiromichi; Abe, Kimihiko; Freeny, P.C.

    1996-01-01

    In order to analyze the usefulness of dynamic contrast-enhanced CT, 84 patients who had hepatocellular carcinoma or suspected hypervascular metastases were studied with conventional incremental dynamic CT (CID-CT) or double helical CT (DH-CT). Delayed phase contrast-enhanced CT studies were consecutively performed in all patients. Thirty-six of 84 patients had malignant hepatic neoplasms; six had hepatocellular carcinoma and 30 had metastatic tumors. At first, the detectability of hepatic lesions was evaluated with bolus dynamic CT and delayed phase CT. Dynamic CT has detected more lesions than delayed CT. Some hepatic lesions described as isodensity were missed on CID-CT. Therefore, delayed phase CT cannot be eliminated when CID-CT is performed. Secondly, hepatic lesion detectability with CID-CT was compared with that of DH-CT. DH-CT did not miss the hepatic lesions picked up by delayed phase CT and was expected to provide excellent detectability of hypervascular hepatic neoplasms. In addition, first helical CT showed most hepatic lesions as areas of obvious hyperdensity, while CID-CT did not show their correct vascularities. So-called hypervascular hepatic tumors, however, were not always hypervascular and were demonstrated as areas of iso-hypodensity even on initial helical scanning. Second helical CT was useful to detect these so-called hypervascular, but actually hypovascular lesions. In conclusion, dynamic CT was helpful in detecting hypervascular hepatic malignant neoplasms, and DH-CT was more accurate than-CID-CT for the detection of hepatic lesions and the evaluation of vascular lesion. (author)

  3. In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT

    Science.gov (United States)

    Mongan, John; Rathnayake, Samira; Fu, Yanjun; Wang, Runtang; Jones, Ella F.; Gao, Dong-Wei

    2012-01-01

    Purpose: To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios. Materials and Methods: Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium. Results: Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase–enhanced CT scan simultaneously in a single examination. Conclusion: Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo. © RSNA, 2012 PMID:22778447

  4. The added value of {sup 68}Ga-DOTA-TATE-PET to contrast-enhanced CT for primary site detection in CUP of neuroendocrine origin

    Energy Technology Data Exchange (ETDEWEB)

    Kazmierczak, Philipp M. [Klinikum der Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Muenchen (Germany); Rominger, Axel; Wenter, Vera [Ludwig-Maximilians-University Hospital Munich, Department of Nuclear Medicine, Muenchen (Germany); Spitzweg, Christine; Auernhammer, Christoph [Ludwig-Maximilians-University Hospital Munich, Department of Internal Medicine II, Muenchen (Germany); Angele, Martin K. [Ludwig-Maximilians-University Hospital Munich, Department of General, Visceral, Transplantation, Vascular and Thoracic Surgery, Muenchen (Germany); Rist, Carsten; Cyran, Clemens C. [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Muenchen (Germany)

    2017-04-15

    To quantify the additional value of {sup 68}Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced {sup 68}Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and {sup 68}Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up {sup 68}Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p < 0.001). {sup 68}Ga-DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. (orig.)

  5. A New Adaptive Gamma Correction Based Algorithm Using DWT-SVD for Non-Contrast CT Image Enhancement.

    Science.gov (United States)

    Kallel, Fathi; Ben Hamida, Ahmed

    2017-12-01

    The performances of medical image processing techniques, in particular CT scans, are usually affected by poor contrast quality introduced by some medical imaging devices. This suggests the use of contrast enhancement methods as a solution to adjust the intensity distribution of the dark image. In this paper, an advanced adaptive and simple algorithm for dark medical image enhancement is proposed. This approach is principally based on adaptive gamma correction using discrete wavelet transform with singular-value decomposition (DWT-SVD). In a first step, the technique decomposes the input medical image into four frequency sub-bands by using DWT and then estimates the singular-value matrix of the low-low (LL) sub-band image. In a second step, an enhanced LL component is generated using an adequate correction factor and inverse singular value decomposition (SVD). In a third step, for an additional improvement of LL component, obtained LL sub-band image from SVD enhancement stage is classified into two main classes (low contrast and moderate contrast classes) based on their statistical information and therefore processed using an adaptive dynamic gamma correction function. In fact, an adaptive gamma correction factor is calculated for each image according to its class. Finally, the obtained LL sub-band image undergoes inverse DWT together with the unprocessed low-high (LH), high-low (HL), and high-high (HH) sub-bands for enhanced image generation. Different types of non-contrast CT medical images are considered for performance evaluation of the proposed contrast enhancement algorithm based on adaptive gamma correction using DWT-SVD (DWT-SVD-AGC). Results show that our proposed algorithm performs better than other state-of-the-art techniques.

  6. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  7. Nephrogenic systemic fibrosis versus contrast-induced nephropathy: risks and benefits of contrast-enhanced MR and CT in renally impaired patients

    DEFF Research Database (Denmark)

    Martin, Diego R; Semelka, Richard C; Chapman, Arlene

    2009-01-01

    -sectional imaging modality. Factors to consider include the relative risks of the contrast agent. Other factors include the relative procedural risks, including radiation risks and the relative expected diagnostic yield of the examination technique (12). In this review we describe both nephrogenic systemic fibrosis...... and contrast-induced nephropathy to compare the implications with regard to relative risks and benefits of contrast-enhanced MRI or CT in patients with impaired renal function. J. Magn. Reson. Imaging 2009;30:1350-1356. (c) 2009 Wiley-Liss, Inc....

  8. Complex cystic renal masses: characterization with contrast-enhanced US.

    Science.gov (United States)

    Ascenti, Giorgio; Mazziotti, Silvio; Zimbaro, Giovanni; Settineri, Nicola; Magno, Carlo; Melloni, Darwin; Caruso, Rosario; Scribano, Emanuele

    2007-04-01

    To prospectively compare contrast material-enhanced ultrasonography (US) with computed tomography (CT) in the classification of complex cystic renal masses with the Bosniak system. Ethics committee approval and written informed consent were obtained. Forty patients (17 women, 23 men; age range, 31-77 years) with 44 complex cystic renal masses detected with conventional US were prospectively examined by using second-harmonic US with a second-generation contrast agent and multiphasic helical CT. Thirty-six patients had one lesion, and four patients had two lesions. Surgical resection in nine patients and imaging follow-up in 31 patients were used to determine the outcome. On contrast-enhanced US images, masses were classified as Bosniak category II (n = 18), IIF (ie, lesions were classified as category II and follow-up was needed) (n = 16), III (n = 7), or IV (n = 3) lesions. On CT images, masses were classified as Bosniak category II (n = 24), IIF (n = 10), III (n = 7), or IV (n = 3) lesions. Interobserver agreement was high (kappa = 0.86, P < .001) for classification with US. Complete concordance between the readers was found for classification with CT. Complete concordance between contrast-enhanced US and CT was observed in the differentiation of surgical and nonsurgical complex cysts. Complete concordance among the three readers in the assessment of vascularity with contrast-enhanced US was found. Interobserver agreement in the evaluation of enhancement on CT images was high (kappa = 0.88, P < .001). Concordance between contrast-enhanced US and CT in the evaluation of vascularization was high (kappa = 0.77, P < .001). The study data suggest that contrast-enhanced second-harmonic US is appropriate for renal cyst classification with the Bosniak system.

  9. Role of contrast-enhanced helical CT in the evaluation of acute thoracic aortic injuries after blunt chest trauma

    International Nuclear Information System (INIS)

    Scaglione, M.; Pinto, A.; Pinto, F.; Romano, L.; Ragozzino, A.; Grassi, R.

    2001-01-01

    The purpose of this retrospective study was to determine the value of contrast-enhanced helical CT for detecting and managing acute thoracic aortic injury (ATAI). Between June 1995 and February 2000, 1419 consecutive chest CT examinations were performed in the setting of major blunt trauma. The following CT findings were considered indicative of ATAI: intimal flap; pseudoaneurysm; contour irregularity; lumen abnormality; and extravasation of contrast material. On the basis of these direct findings no further diagnostic investigations were performed. Isolated mediastinal hematoma on CT scans was considered an indirect sign of ATAI: In these cases, thoracic aortography was performed even if CT indicated normal aorta. Seventy-seven patients had abnormal CT scans: Among the 23 patients with direct CT signs, acute thoracic aortic injuries was confirmed at thoracotomy in 21. Two false-positive cases were observed. The 54 remaining patients had isolated mediastinal hematoma without aortic injuries at CT and corresponding negative angiograms. The 1342 patients with negative CT scans were included in the 8-month follow-up program and did not show any adverse sequela based on clinical and radiographic criteria. Contrast-enhanced helical CT has a critical role in the exclusion of thoracic aortic injuries in patient with major blunt chest trauma and prevents unnecessary thoracic aortography. Direct CT signs of ATAI do not require further diagnostic investigations to confirm the diagnosis: Isolated aortic bands or contour vessel abnormalities should be first considered as possible artifacts or related to non-traumatic etiologies especially when mediastinal hematoma is absent. In cases of isolated mediastinal hematoma other possible sources of bleeding should be considered before directing patients to thoracic aortography. (orig.)

  10. Dynamic contrast-enhanced CT in advanced lung cancer after chemotherapy with/within radiation therapy: Can it predict treatment responsiveness of the tumor?

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Mi Ri; Whang, Sung Ho; Park, Chul Hwan; Kim, Sang Jin; Kim, Tae Hoon [Dept. of Radiology and Research Institute of Radiological Science, Yonsei University Health System, Seoul (Korea, Republic of)

    2013-08-15

    To evaluate the contrast enhancement patterns of lung cancer after chemotherapy using a dynamic contrast-enhanced (DCE) CT and to determine whether the enhancement patterns of tumors at early stages of treatment can predict treatment responses. Forty-two patients with advanced lung cancers underwent DCE-CT and follow-up CT after chemotherapy. We evaluated peak and net enhancement (PE and NE, respectively) and time-density curves (TDCs) (type A, B, C, and D) on DCE-CT images. Treatment responses were evaluated using revised Response Evaluation Criteria in Solid Tumor criteria. NE and PE values were significantly higher in the progressive disease (PD) groups than in the stable disease (SD) or partial response (PR) groups (p < 0.05). Types B, C, and D on TDCs were observed mostly in the PR and SD groups (96.0%), whereas type A was most frequent in the SD and PD groups (97.2%), which were significantly different in terms of PE and NE. Contrast enhancement pattern regarding the response of treatment on DCE-CT images could be helpful in predicting treatment response of advanced lung cancer after treatment.

  11. Virtual Non-Contrast CT Using Dual-Energy Spectral CT: Feasibility of Coronary Artery Calcium Scoring

    OpenAIRE

    Song, Inyoung; Yi, Jeong Geun; Park, Jeong Hee; Kim, Sung Mok; Lee, Kyung Soo; Chung, Myung Jin

    2016-01-01

    Objective To evaluate the feasibility of coronary artery calcium scoring based on three virtual noncontrast-enhanced (VNC) images derived from single-source spectral dual-energy CT (DECT) as compared with true noncontrast-enhanced (TNC) images. Materials and Methods This prospective study was conducted with the approval of our Institutional Review Board. Ninety-seven patients underwent noncontrast CT followed by contrast-enhanced chest CT using single-source spectral DECT. Iodine eliminated V...

  12. Blunt renal trauma: comparison of contrast-enhanced CT and angiographic findings and the usefulness of transcatheter arterial embolization

    International Nuclear Information System (INIS)

    Kitase, M.; Mizutani, M.; Tomita, H.; Kono, T.; Sugie, C.; Shibamoto, Y.

    2007-01-01

    Full text: Background: The purpose of this study was to evaluate the role of contrast-enhanced CT and the usefulness of super selective embolization therapy in the management of arterial damage in patients with severe blunt renal trauma. Patients and Methods: Nine cases of severe renal trauma were evaluated. In all cases, we compared contrast enhanced CT findings with angiographic findings, and performed transcatheter arterial embolization (TAE) in six of them with microcoils and gelatin sponge particles. Morphological changes in the kidney and site of infarction after TAE were evaluated on follow-up CT Chronological changes in blood biochemistry findings after injury, degree of anemia and renal function were investigated. Adverse effects or complications such as duration of hematuria, fever, abdominal pain, renovascular hypertension and abscess formation were also evaluated. Results: The CT finding of extravasation was a reliable sign of active bleeding and useful for determining the indication of TAE. In all cases, bleeding was effectively controlled with super selective embolization. There was minimal procedure-related loss of renal tissue. None of the patients developed abscess, hypertension or other complications. Conclusions: In blunt renal injury, contrast-enhanced CT was useful for diagnosing arterial hemorrhage. Arterial bleeding may produce massive hematoma and TAE was a useful treatment for such cases. By using selective TAE for a bleeding artery, it was possible to minimize renal parenchymal damage, with complications of TAE rarely seen. (author)

  13. Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

    Science.gov (United States)

    Yeh, Benjamin M; FitzGerald, Paul F; Edic, Peter M; Lambert, Jack W; Colborn, Robert E; Marino, Michael E; Evans, Paul M; Roberts, Jeannette C; Wang, Zhen J; Wong, Margaret J; Bonitatibus, Peter J

    2017-04-01

    The introduction of spectral CT imaging in the form of fast clinical dual-energy CT enabled contrast material to be differentiated from other radiodense materials, improved lesion detection in contrast-enhanced scans, and changed the way that existing iodine and barium contrast materials are used in clinical practice. More profoundly, spectral CT can differentiate between individual contrast materials that have different reporter elements such that high-resolution CT imaging of multiple contrast agents can be obtained in a single pass of the CT scanner. These spectral CT capabilities would be even more impactful with the development of contrast materials designed to complement the existing clinical iodine- and barium-based agents. New biocompatible high-atomic number contrast materials with different biodistribution and X-ray attenuation properties than existing agents will expand the diagnostic power of spectral CT imaging without penalties in radiation dose or scan time. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Arterio-venous anastomoses in mice affect perfusion measurements with dynamic contrast enhanced CT

    International Nuclear Information System (INIS)

    Gabra, Peter; Lee, Ting-Yim; Shen, Gang; Xuan, Jim

    2010-01-01

    Accurate measurement of perfusion with dynamic contrast enhanced CT requires an arterial input curve (AIC) uncontaminated by venous sources. Arterio-venous anastomoses (AVAs) are sources of contamination if contrast is injected intravenously. We seek to identify AVAs in mice and associated errors in perfusion measurements. Six transgenic mice with spontaneous prostate tumor were scanned with a micro-CT scanner (GE Healthcare (GE)) using a high resolution anatomical and a lower resolution perfusion protocol. For the anatomical protocol, a CT scan was performed during injection of an iodinated contrast agent (Hypaque) into a tail vein. Images covering the thoracic, abdominal and pelvic regions at an isotropic resolution of 175 µm were reconstructed and rendered in 3D to show the arterial and venous tree (Advantage Window, GE). For the perfusion protocol, each mouse was continuously scanned for 40 s and the contrast agent (Hypaque) was injected via a tail vein 5 s into scanning. Tumor images were reconstructed every second. Tumor blood flow (BF) and volume (BV) maps were calculated with CT perfusion software (GE) using AIC measured either from abdominal aorta (AA) or tail (caudal) artery (TA). In all mice, there was an AVA from the bifurcation of the inferior vena cava to the tail artery shunting venous blood and portion of the contrast agent injected into the tail vein into the TA. Contrast arrival time at the TA preceded that at the AA by 3.3 ± 0.5 s (P < 0.05). Mean tumor BV and BF values calculated with AA versus TA were 10.0 ± 1.8 versus 4.8 ± 2.1 ml (100 g) −1 (P < 0.05) and 108.8 ± 26.5 versus 33.0 ± 8.5 ml min −1 100 g −1 (P < 0.05), respectively. AVA in the murine pelvic region can result in inaccurate and more variable measurements of pelvic organ/tissue perfusion when the tail artery is used as the AIC

  15. Dynamic multidetector CT and non-contrast-enhanced MR for right adrenal vein imaging: comparison with catheter venography in adrenal venous sampling

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideki; Seiji, Kazumasa; Kawabata, Masahiro; Satani, Nozomi; Matsuura, Tomonori; Tominaga, Junya; Takase, Kei [Tohoku University Hospital, Department of Diagnostic Radiology, Sendai (Japan); Omata, Kei; Ono, Yoshikiyo; Iwakura, Yoshitsugu; Morimoto, Ryo; Kudo, Masataka; Satoh, Fumitoshi; Ito, Sadayoshi [Tohoku University Hospital, Division of Nephrology, Endocrinology and Vascular Medicine, Sendai (Japan)

    2016-03-15

    To evaluate visualization of the right adrenal vein (RAV) with multidetector CT and non-contrast-enhanced MR imaging in patients with primary aldosteronism. A total of 125 patients (67 men) scheduled for adrenal venous sampling (AVS) were included. Dynamic 64-detector-row CT and balanced steady-state free precession-based non-contrast-enhanced 3-T MR imaging were performed. RAV visualization based on a four-point score was documented. Both anatomical location and variation on cross-sectional imaging were evaluated, and the findings were compared with catheter venography as the gold standard. The RAV was visualized in 93.2 % by CT and 84.8 % by MR imaging (p = 0.02). Positive predictive values of RAV visualization were 100 % for CT and 95.2 % for MR imaging. Imaging score was significantly higher in CT than MR imaging (p < 0.01). The RAV formed a common trunk with an accessory hepatic vein in 16 % of patients. The RAV orifice level on cross-sectional imaging was concordant with catheter venography within the range of 1/3 vertebral height in >70 % of subjects. Success rate of AVS was 99.2 %. Dynamic CT is a reliable way to map the RAV prior to AVS. Non-contrast-enhanced MR imaging is an alternative when there is a risk of complication from contrast media or radiation exposure. (orig.)

  16. Baseline incidence and severity of renal insufficiency evaluated by estimated glomerular filtration rates in patients scheduled for contrast-enhanced CT

    International Nuclear Information System (INIS)

    Utsunomiya, Daisuke; Yanaga, Yumi; Oda, Seitaro; Namimoto, Tomohiro; Yamashita, Yasuyuki; Awai, Kazuo; Funama, Yoshinori

    2011-01-01

    Background Although pre-existing renal insufficiency (RI) is the most important risk factor for contrast-induced nephropathy (CIN), the background distribution of baseline renal function has not been investigated thoroughly in patients scheduled for contrast-enhanced CT. Purpose To investigate the incidence and severity of baseline RI evaluated by estimated glomerular filtration rates (eGFR) in patients who underwent contrast-enhanced CT at an academic center. Material and Methods A total of 6586 patients (3630 men and 2956 women; mean age 57.0 ± 11.9 years) who underwent contrast-enhanced CT between January and December 2008 were retrospectively studied. Of these, 829 had cardiovascular diseases (CVD), 5116 had oncologic diseases, 178 had diabetes mellitus (DM), and 1572 had chronic liver disease (CLD). The eGFR (mL/min/1.73 m 2 ) was calculated from their serum creatinine level. Mild, moderate-a, moderate-b, and severe RI were recorded at 60 2 at baseline was high in patients with advanced age, CVD and DM and in patients without oncologic disease

  17. Computer-aided diagnosis in contrast-enhanced CT colonography: an approach based on contrast

    International Nuclear Information System (INIS)

    Luboldt, Wolfgang; Kroll, Manuela; Vogl, Thomas J.; Mann, Carolin; Vonthein, Reinhard; Stueker, Dietmar; Luz, Oliver; Claussen, Claus D.; Tryon, Cathy L.

    2002-01-01

    Automation in colorectal mass detection is achieved as soon as the voxels representing colorectal masses can be automatically segmented. We tested the Hounsfield (HU) value in intensely contrast enhanced high-resolution CT colonography for automated segmentation of colorectal masses in 18 patients with 35 polyps (28<10 mm, 7 ≥10 mm) and 7 carcinomas. Mean HU values of the colonic wall and masses were determined to deduce a gradient threshold for a segmentation process, which encodes the voxels bordering the colonic lumen with a colour ranging in intensity from 0 to 100% according to the selected gradient threshold range in the volume rendering. The results of the automated segmentation process were superimposed on a virtual double contrast and endoscopic display and validated through correlation with morphology. Mean HU values and their standard deviations for the colonic wall, polyps <10 mm, polyps ≥10 mm and carcinomas were 63±24, 154±38, 116±41 and 108±29 HU, respectively. A gradient threshold ranging from 90 to 160 HU resulted in colour pools in 6 of 7 of polyps ≥10 mm, and 6 of 7 carcinomas that were significant enough to prospectively guide the reader's attention to these masses. Due to the superposition of ''false-positive'' voxels in the projection view, the virtual endoscopic perspective was superior to the virtual double contrast display for controlling the segmentation results. The HU value is promising for automated segmentation of colorectal masses but needs to be combined with morphological parameters to render automated colorectal mass detection more accurate. Further refinements of the method with subsequent analysis of its accuracy, as well as analogue studies with contrast-enhanced MRI, appear warranted. More information at http://www.multiorganscreening.org (orig.)

  18. PET/CT and contrast enhanced CT in single vs. two separate sessions: a cost analysis study.

    Science.gov (United States)

    Picchio, M; Mansueto, M; Crivellaro, C; Guerra, L; Marcelli, S; Arosio, M; Sironi, S; Gianolli, L; Grimaldi, A; Messa, C

    2012-06-01

    Aim of the study was to quantify the economic impact of PET/CT and contrast enhanced (c.e.) CT performed in a single session examination vs. stand-alone modalities in oncological patients. One-hundred-forty-five cancer patients referred to both PET/CT and c.e. CT, to either stage (N.=46) or re-stage (N.=99) the disease, were included. Seventy-two/145 performed both studies in a single session (innovative method) and 73/145 in two different sessions (traditional method). The cost-minimization analysis was performed by evaluating: 1) institutional costs, data obtained by hospital accountability (staff, medical materials, equipment maintenance and depreciation, departments utilities); 2) patients costs, data obtained by a specific survey provided to patients (travel, food, accommodation costs, productivity loss). Economic data analysis showed that the costs for innovative method was lower than those of traditional method, both for Institution (106 € less per test) and for patient (21 € less per patient). The loss of productivity for patient and caregivers resulted lower for the innovative method than the traditional method (3 work-hour less per person). PET/CT and c.e. CT performed in a single session is more cost-effective than stand-alone modalities, by reducing both Institutional and patients costs. These advantages are mainly due to lower Institutional cost (single procedure) and to lower cost related to travel and housing.

  19. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  20. Multislice CT of the liver. Effects of contrast material pushed with saline solution on hepatic enhancement

    International Nuclear Information System (INIS)

    Sekiguchi, Ryuzo; Hayashi, Takayuki; Tsukamoto, Tatsuaki; Kuroki, Yoshinori; Nasu, Katsuhiro; Murakami, Koji; Nawano, Shigeru

    2004-01-01

    The purpose of this study was to evaluate the usefulness of a method of power injection of contrast material pushed with saline solution for hepatic multislice CT using a dual-head power injector. One hundred twenty-one patients who underwent multislice CT to detect liver metastases were divided into two groups, depending on the protocol of contrast material administration: 100 mL of non-ionic contrast material (370 mgI/mL) or 100 mL of the same contrast material pushed with 30 mL of saline solution. Both contrast material and saline solution were administered at a rate of 2.5 mL/sec using a dual-head power injector. Attenuation values for the two protocols were obtained from the liver, portal vein, and descending aorta. Hepatic enhancement above 50 Hounsfield unit (HU), which is needed for the diagnosis of liver metastases, was achieved in 76.5% of patients given 100 mL of contrast material and 92.5% of those given 100 mL of contrast material pushed with a 30 mL saline solution. In contingency-table analysis, the CT attenuation value of liver categorized as less than 50 HU or more than 50 HU, showed a good relation between the categorized group and the protocol (p=0.0437). In patients with a body weight of 50 kg or more, 100 mL of contrast material pushed with saline solution provided significantly better CT attenuation values in the liver (p=0.0113), portal vein (p=0.0094), and descending aorta (p=0.0394) than those provided by the injection of 100 mL of contrast material alone. When contrast material pushed with saline solution was used, CT attenuation values in the liver were significantly increased, especially in patients with a body weight of 50 kg or more. This technique will provide a decrease in the volume of contrast material administered and a potential decrease in the side effects of contrast material. (author)

  1. Isoattenuating insulinomas at biphasic contrast-enhanced CT: frequency, clinicopathologic features and perfusion characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Liang; Xue, Hua-dan; Sun, Hao; Wang, Xuan; He, Yong-lan; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)

    2016-10-15

    We aimed to determine the frequency of isoattenuating insulinomas, to investigate their clinicopathological features and to assess their regional pancreatic perfusion characteristics. Institutional review board approval was obtained, and patient informed consent was waived. From July 2010 to June 2014, 170 patients (66 male, 104 female) with endogenous hyperinsulinemic hypoglycemia underwent biphasic contrast-enhanced CT before surgery, and 129 of those patients also received preoperative whole-pancreas CT perfusion. A total of 181 tumours were proved histopathologically after surgery. Enhancement pattern and regional pancreatic perfusion characteristics were analyzed. Clinical features, tumour size and pathological grading were investigated. The frequency of isoattenuating tumours was 24.9 %. Tumour size and WHO grading was not significantly different between isoattenuating and hyperattenuating tumours. Tumour-free regions had identical blood flow (BF) regardless of their location (p = 0.35). Isoattenuating tumour-harbouring regions had lower BF compared with hyperattenuating tumour-harbouring regions; both showed higher BF compared with tumour-free neighbourhood regions (all p < 0.01). For patients with isoattenuating tumours, the overall hospital stay was longer (p < 0.01). A substantial subset of insulinomas were isoattenuating on biphasic CT. CT perfusion showed higher BF in tumour-harbouring regions compared to tumour-free regions, providing a clue for tumour regionalization. (orig.)

  2. Detection of parenchymal abnormalities in experimentally induced acute pyelonephritis in rabbits using contrast-enhanced ultrasonography, CT, and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Ah; Kim, Bo Hyun; Kim, Seung Kwon; Seo, Jin Won [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Jong Sung [Laboratory Animal Research Center, Samsung Biomedical Research Institute, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    We evaluated the efficacy of contrast-enhanced ultrasonography (CEUS) in detecting acute pyelonephritis (APN) using the rabbit kidney model and compared it with CT and MRI. This study was approved by the Institutional Review Board. In a total of 20 New Zealand White rabbits, APN was induced experimentally. CEUS, CT, and MRI were performed on the first, third, and seventh postoperative days. After imaging studies, the subjects were sacrificed and the pathological diagnosis of APN was confirmed in each animal by a pathologist. Imaging studies were obtained in eight animals, including eight CEUS, four computed tomography (CT), and four magnetic resonance imaging (MRI) images. CEUS depicted diffuse renal enlargement (7), diffuse heterogeneous parenchymal enhancement (6), and focal areas of decreased parenchymal enhancement (6). These findings were well correlated with the CT and MRI findings in five cases in which these studies were available. CT and MRI showed diffuse renal enlargement, diffuse heterogeneous parenchymal enhancement, focal areas of decreased parenchymal enhancement, focal contour bulging, and the finding of perinephric spread of infection. In a rabbit model, CEUS could depict the parenchymal lesions of APN similar to CT or MRI; however, it was limited in depicting the perinephric extension of inflammation.

  3. Multiple renal aspergillus abscesses in an AIDS patient: contrast-enhanced helical CT and MRI findings

    International Nuclear Information System (INIS)

    Heussel, C.P.; Kauczor, H.U.; Thelen, M.; Heussel, G.; Jahn, B.

    1999-01-01

    Renal insufficiency or allergic reactions for X-ray contrast agents are frequent limitations in immunocompromised hosts such as neutropenic or AIDS patients. Due to a better tolerance of contrast agents in MRI, this technique is well suited for investigation of parenchymal organs. We demonstrate an allergic AIDS patient who presented with fever and flank pain. At sonography, anechoic renal lesions were supposed to be non-complicated cysts; however, on T2-weighted MRI, the center was of high signal. Dynamic contrast-enhanced MRI of the kidneys demonstrated an enhancing rim with ill-defined margins. The lesions were supposed to be multiple bilateral abscesses. Due to the multiple dynamic contrast series, a delayed enhancement of renal parenchyma was detectable adjacent to the lesion. This was suggested as accompanying local pyelonephritis and an infectious etiology became more reliable. Aspergillus fumigatus was identified by CT-guided biopsy as the underlying microorganism. The MR appearance of this manifestation has not been described previously. (orig.)

  4. Differentiation of focal-type autoimmune pancreatitis from pancreatic carcinoma: assessment by multiphase contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Furuhashi, Naohiro; Suzuki, Kojiro; Sakurai, Yusuke; Naganawa, Shinji [Nagoya University Graduate School of Medicine, Department of Radiology, Nagoya (Japan); Ikeda, Mitsuru [Nagoya University Graduate School of Medicine, Department of Radiological Technology, Nagoya (Japan); Kawai, Yuichi [Japanese Red Cross Nagoya Daiichi Hospital, Department of Diagnostic Radiology, Nagoya (Japan)

    2015-05-01

    To evaluate the utility of multiphase contrast-enhanced computed tomography (CT) findings alone and in combination for differentiating focal-type autoimmune pancreatitis (f-AIP) from pancreatic carcinoma (PC). The study group comprised 22 f-AIP lesions and 61 PC lesions. Two radiologists independently evaluated CT findings. Frequencies of findings were compared between f-AIP and PC. Statistical, univariate and multivariate analyses were performed. Homogeneous enhancement during the portal phase (AIP, 59 % vs. PC, 3 %; P < 0.001), dotted enhancement during the pancreatic phase (50 % vs. 7 %; P < 0.001), duct-penetrating sign (46 % vs. 2 %; P < 0.001), enhanced duct sign (36 % vs. 2 %; P < 0.001) and capsule-like rim (46 % vs. 3 %; P < 0.001) were more frequently observed in AIP. Ring-like enhancement during the delayed phase (5 % vs. 46 %; P < 0.001) and peripancreatic strands with a length of at least 10 mm (5 % vs. 39 %; P = 0.001) were more frequently observed in PC. AIP was identified with 82 % sensitivity and 98 % specificity using four of these seven findings. Multivariate analysis revealed significant differences in dotted enhancement (P = 0.004), duct-penetrating sign (P < 0.001) and capsule-like rim (P = 0.007). The combination of CT findings may allow improvements in differentiating f-AIP from PC. (orig.)

  5. Peripancreatic vascular abnormalities complicating acute pancreatitis: contrast-enhanced helical CT findings

    International Nuclear Information System (INIS)

    Mortele, Koenraad J.; Mergo, Patricia J.; Taylor, Helena M.; Wiesner, Walter; Cantisani, Vito; Ernst, Michael D.; Kalantari, Babak N.; Ros, Pablo R.

    2004-01-01

    Objective: To determine the prevalence and morphologic helical computed tomography (CT) features of peripancreatic vascular abnormalities in patients with acute pancreatic inflammatory disease in correlation with the severity of the pancreatitis. Materials and methods: One hundred and fifty-nine contrast-enhanced helical CT scans of 100 consecutive patients with acute pancreatitis were retrospectively and independently reviewed by three observers. CT scans were scored using the CT severity index (CTSI): pancreatitis was graded as mild (0-2 points), moderate (3-6 points), and severe (7-10 points). Interobserver agreement for both the CT severity index and the presence of peripancreatic vascular abnormalities was calculated (K-statistic). Correlation between the prevalence of complications and the degree of pancreatitis was estimated using Fisher's exact test. Results: The severity of pancreatitis was graded as mild (n=59 scans), moderate (n=82 scans), and severe (n=18 scans). Venous abnormalities detected included splenic vein (SV) thrombosis (31 scans, 19 patients), superior mesenteric vein (SMV) thrombosis (20 scans, 14 patients), and portal vein (PV) thrombosis (17 scans, 13 patients). Arterial hemorrhage occurred in five patients (6 scans). In our series, no cases of arterial pseudoaneurysm formation were detected. The interobserver agreement range for scoring the degree of pancreatitis and the overall presence of major vascular abnormalities was 75.5-79.2 and 86.2-98.8%, respectively. The presence of the vascular abnormalities in correlation with the severity of pancreatitis was variable. Conclusion: Vascular abnormalities are relatively common CT findings in association with acute pancreatitis. The CT severity index is insufficiently accurate in predicting some of these complications since no statistically significant correlation between their prevalence and the severity of pancreatitis could be established

  6. Change in contrast enhancement of HCC on 1-month follow-up CT after local radiotherapy: An early predictor of final treatment response

    International Nuclear Information System (INIS)

    Kim, Eun Young; Choi, Dongil; Lim, Do Hoon; Lee, Won Jae; Yoo, Byung Chul; Paik, Seung Woon

    2009-01-01

    Background: The purpose of this study was to evaluate the change in contrast enhancement of HCC on 1-month follow-up CT after local radiotherapy (RT) as an early predictor of final treatment response. Materials: Fifty patients who underwent local RT for HCCs had both pre-RT and post-RT CT scans including 1-month follow-up CT. We assessed the final treatment response by using the change in maximal tumor size on 6-12-month follow-up CT scan after RT. We also evaluated the change in tumor enhancement between pre-RT and 1-month follow-up CT scans. Results: A final treatment response was achieved in 27 (54%) of 50 patients, who showed either a complete response (n = 11) or a partial response (n = 16). Compared with non-responsive patients (n = 23), responsive patients showed a significant decrease in tumor enhancement on 1-month follow-up CT after RT in both objective and subjective analyses (each P < 0.001). Conclusion: The change in contrast enhancement of HCC seen on the 1-month follow-up CT in patients after local RT may be used as an early predictor of final treatment response.

  7. Quantitative analysis of contrast enhancement of transplanted kidneys under computed tomography

    International Nuclear Information System (INIS)

    Fujita, Tamio; Asano, Haruyoshi; Yanaoka, Masanori; Moriguchi, Ryuichiro; Okishio, Norihiko

    1981-01-01

    Using Hitachi CT-3, the changes in CT numbers of the kidney were calculated in 10 normal and 12 transplanted kidneys. Two mililiters per kg of meglumine diatrizoate (Angiografin) was given intravenously in bolus fashion. Kidneys were scanned before injection, at termination of injection and correctly 10 minutes after injection. In control group, the CT numbers of the cortex, the medulla and the aorta showed rapid increase after contrast administration. Ten minutes after administration of medium, the CT numbers of the medulla remained a little higher than the cortex, though that of the aorta showed rapid decrease. In contrast to control group, in transplanted kidneys the CT numbers of the cortex and medulla showed less increase than the control group just after contrast administration. Moreover, in the recipients who have had good graft function the CT numbers of the cortex and medulla showed gradual increase, in the recipients who have had poor graft function the CT numbers showed gradual decrease 10 minutes after injection. Enhancing indices calculated from the formula: CT numbers 10 minutes after contrast enhancement CT numbers before contrast enhancement were inversely proportional to the serum creatinine. These results lead to the conclusion that the CT scans employing contrast enhancement method after kidney transplantation has the diagnostic value of graft function in addition to diagnostic usefulness for post-transplantation complications such as hematoma, urinoma or lymphocele. (author)

  8. CT findings of intraductal papillary neoplasm of the bile duct: Assessment with multiphase contrast-enhanced examination using multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, H., E-mail: ogawa.hiroshi@h.mbox.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Itoh, S. [Department of Radiology, Japanese Red Cross Nagoya Daiichi Hospital, Nagoya (Japan); Nagasaka, T. [Department of Medical Technology, Nagoya University School of Health Sciences, Nagoya (Japan); Suzuki, K. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Ota, T. [Department of Radiology, Aichi Medical University Hospital, Nagakute Aichi (Japan); Naganawa, S. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2012-03-15

    Aim: To evaluate multi-detector computed tomography (MDCT) findings of intraductal papillary neoplasm of the bile duct (IPNB), a neoplasm that is considered to be the biliary counterpart of pancreatic intraductal papillary mucinous neoplasm. Materials and methods: Two radiologists retrospectively evaluated multiphase contrast-enhanced CT images with 0.5 or 1 mm collimation in 37 consecutive patients with resected IPNB diagnosed by a single pathologist. The CT findings were correlated with the pathological findings concerning invasion of the surrounding organs and vessels. Results: All patients showed bile duct dilatation. An intraductal mass was detected in 36 patients and the following findings were observed: extensive infiltration along the bile duct more than 20 mm (n = 32), compared with normal hepatic parenchyma, isodense or hyperdense during the late arterial phase (n = 31), not hyperdense during the portal-venous and delayed phases (n = 36), and intense enhancement rim at the base of the mass during the portal-venous or delayed phase (n = 27). Parenchymal invasion of the surrounding organs was seen in eight of 16 tumours showing irregular or bulging margins. Vascular invasion was false positive in four of eight tumours. Conclusions: IPNB exhibits relatively characteristic findings with multiphase contrast-enhanced examination using MDCT. A tendency to overestimate invasion of the surrounding organs and vessels was seen.

  9. Rheumatoid arthritis of the craniocervical region: assessment and characterization of inflammatory soft tissue proliferations with unenhanced and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Czerny, C.; Grampp, S.; Henk, C.B. [University Hospital Vienna (Austria). Dept. of Radiology; Neuhold, A. [Institute for Diagnostic Imaging, Hospital Rudolfinerhaus, Vienna (Austria); Stiskal, M. [Institute for Diagnostic Imaging, Hospital Lainz, Vienna (Austria); Smolen, J. [Department of Rheumatology, University Hospital Vienna (Austria)

    2000-09-01

    The aim of this study was to depict and characterize inflammatory soft tissue proliferations caused by rheumatoid arthritis (RA) in the craniocervical region by unenhanced and contrast-enhanced CT. Computed tomography of the craniocervical region was performed in 35 patients in the axial plane before and after the i. v. administration of contrast material. According to the densities and contrast enhancement of the inflammatory soft tissue proliferations, four groups were classified. Ancillary findings, such as a compression of the dural sac or spinal cord, erosions of the bony structures, and atlantoaxial subluxation, were also evaluated. Inflammatory soft tissue proliferations were depicted in 28 of 35 patients and could be differentiated by unenhanced and contrast-enhanced CT according to the above defined criteria: effusion in 6 patients (17 %); hypervascular pannus in 8 (23 %); hypovascular pannus in 5 (14 %); and fibrous tissue in 9 patients (26 %). A compression of the dural sac was seen in 11 (31 %) patients; 3 of these had neurological symptoms. Erosions of the odontoid process were found in 20 (57 %) patients; 16 (80 %) of these also showed erosions of the atlas. Atlantoaxial subluxation was seen in 11 (31 %) patients. Inflammatory soft tissue proliferations in the craniocervical region caused by RA can be reliably demonstrated and classified by unenhanced and contrast-enhanced CT, which can differentiate between joint effusion and various forms of pannus and depict ancillary findings. Computed tomography is an alternative method for patients unable to undergo an MRI examination. (orig.)

  10. Rheumatoid arthritis of the craniocervical region: assessment and characterization of inflammatory soft tissue proliferations with unenhanced and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Czerny, C.; Grampp, S.; Henk, C.B.; Stiskal, M.; Smolen, J.

    2000-01-01

    The aim of this study was to depict and characterize inflammatory soft tissue proliferations caused by rheumatoid arthritis (RA) in the craniocervical region by unenhanced and contrast-enhanced CT. Computed tomography of the craniocervical region was performed in 35 patients in the axial plane before and after the i. v. administration of contrast material. According to the densities and contrast enhancement of the inflammatory soft tissue proliferations, four groups were classified. Ancillary findings, such as a compression of the dural sac or spinal cord, erosions of the bony structures, and atlantoaxial subluxation, were also evaluated. Inflammatory soft tissue proliferations were depicted in 28 of 35 patients and could be differentiated by unenhanced and contrast-enhanced CT according to the above defined criteria: effusion in 6 patients (17 %); hypervascular pannus in 8 (23 %); hypovascular pannus in 5 (14 %); and fibrous tissue in 9 patients (26 %). A compression of the dural sac was seen in 11 (31 %) patients; 3 of these had neurological symptoms. Erosions of the odontoid process were found in 20 (57 %) patients; 16 (80 %) of these also showed erosions of the atlas. Atlantoaxial subluxation was seen in 11 (31 %) patients. Inflammatory soft tissue proliferations in the craniocervical region caused by RA can be reliably demonstrated and classified by unenhanced and contrast-enhanced CT, which can differentiate between joint effusion and various forms of pannus and depict ancillary findings. Computed tomography is an alternative method for patients unable to undergo an MRI examination. (orig.)

  11. Contrast-enhanced computed tomography does not improve the diagnostic value of parathyroid dual-phase MIBI SPECT/CT

    DEFF Research Database (Denmark)

    Andersen, Trine B; Aleksyniene, Ramune; Boldsen, Søren K

    2018-01-01

    OBJECTIVE: The aim of this study was to investigate the contribution of contrast-enhanced computed tomography (CE-CT) to the localization of parathyroid adenomas compared with the dual-phase Tc-99m MIBI SPECT with low-dose CT (LD-CT). PATIENTS AND METHODS: This retrospective study included...... consecutive patients with primary hyperparathyroidism who underwent a preoperative dual-phase MIBI SPECT/CT followed by surgical resection. The standard of care was dual-phase MIBI SPECT/CT, acquired with LD-CT in the early phase and CE-CT in the late phase (SPECT/CE-CT). The presence and localization...... of positive sites were extracted from study reports. To examine the role of CE-CT, patient cases were independently re-reviewed, with the early LD-CT fused with early and late SPECT (SPECT/LD-CT). The two SPECT/CT methods were compared for sensitivity, and the positive predictive value and histopathology were...

  12. Intravenous contrast injection significantly affects bone mineral density measured on CT

    Energy Technology Data Exchange (ETDEWEB)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J.J.; Hoesein, Firdaus A.A.M.; Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology and Internal Medicine-Geriatrics, Postbus 85500, Postbox: E.03.511, GA, Utrecht (Netherlands)

    2014-09-05

    The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. One hundred and fifty-two patients (99 without and 53 with malignant neoplasm) who underwent both unenhanced and two contrast-enhanced (arterial and portal venous phase) abdominal CT examinations in a single session between June 2011 and July 2013 were included. BMD was evaluated on the three examinations as CT-attenuation values in Hounsfield Units (HU) in the first lumbar vertebra (L1). CT-attenuation values were significantly higher in both contrast-enhanced phases, compared to the unenhanced phase (p < 0.01). In patients without malignancies, mean ± standard deviation (SD) HU-values increased from 128.8 ± 48.6 HU for the unenhanced phase to 142.3 ± 47.2 HU for the arterial phase and 147.0 ± 47.4 HU for the portal phase (p < 0.01). In patients with malignancies, HU-values increased from 112.1 ± 38.1 HU to 126.2 ± 38.4 HU and 130.1 ± 37.3 HU (p < 0.02), respectively. With different thresholds to define osteoporosis, measurements in the arterial and portal phase resulted in 7-25 % false negatives. Our study showed that intravenous contrast injection substantially affects BMD-assessment on CT and taking this into account may improve routine assessment of low BMD in nonquantitative CT. (orig.)

  13. Intravenous contrast injection significantly affects bone mineral density measured on CT

    International Nuclear Information System (INIS)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J.J.; Hoesein, Firdaus A.A.M.; Jong, Pim A. de

    2015-01-01

    The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. One hundred and fifty-two patients (99 without and 53 with malignant neoplasm) who underwent both unenhanced and two contrast-enhanced (arterial and portal venous phase) abdominal CT examinations in a single session between June 2011 and July 2013 were included. BMD was evaluated on the three examinations as CT-attenuation values in Hounsfield Units (HU) in the first lumbar vertebra (L1). CT-attenuation values were significantly higher in both contrast-enhanced phases, compared to the unenhanced phase (p < 0.01). In patients without malignancies, mean ± standard deviation (SD) HU-values increased from 128.8 ± 48.6 HU for the unenhanced phase to 142.3 ± 47.2 HU for the arterial phase and 147.0 ± 47.4 HU for the portal phase (p < 0.01). In patients with malignancies, HU-values increased from 112.1 ± 38.1 HU to 126.2 ± 38.4 HU and 130.1 ± 37.3 HU (p < 0.02), respectively. With different thresholds to define osteoporosis, measurements in the arterial and portal phase resulted in 7-25 % false negatives. Our study showed that intravenous contrast injection substantially affects BMD-assessment on CT and taking this into account may improve routine assessment of low BMD in nonquantitative CT. (orig.)

  14. TH-EF-207A-04: A Dynamic Contrast Enhanced Cone Beam CT Technique for Evaluation of Renal Functions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Z; Shi, J; Yang, Y [University of Miami School of Medicine, Miami, FL (United States)

    2016-06-15

    Purpose: To develop a simple but robust method for the early detection and evaluation of renal functions using dynamic contrast enhanced cone beam CT technique. Methods: Experiments were performed on an integrated imaging and radiation research platform developed by our lab. Animals (n=3) were anesthetized with 20uL Ketamine/Xylazine cocktail, and then received 200uL injection of iodinated contrast agent Iopamidol via tail vein. Cone beam CT was acquired following contrast injection once per minute and up to 25 minutes. The cone beam CT was reconstructed with a dimension of 300×300×800 voxels of 130×130×130um voxel resolution. The middle kidney slices in the transvers and coronal planes were selected for image analysis. A double exponential function was used to fit the contrast enhanced signal intensity versus the time after contrast injection. Both pixel-based and region of interest (ROI)-based curve fitting were performed. Four parameters obtained from the curve fitting, namely the amplitude and flow constant for both contrast wash in and wash out phases, were investigated for further analysis. Results: Robust curve fitting was demonstrated for both pixel based (with R{sup 2}>0.8 for >85% pixels within the kidney contour) and ROI based (R{sup 2}>0.9 for all regions) analysis. Three different functional regions: renal pelvis, medulla and cortex, were clearly differentiated in the functional parameter map in the pixel based analysis. ROI based analysis showed the half-life T1/2 for contrast wash in and wash out phases were 0.98±0.15 and 17.04±7.16, 0.63±0.07 and 17.88±4.51, and 1.48±0.40 and 10.79±3.88 minutes for the renal pelvis, medulla and cortex, respectively. Conclusion: A robust method based on dynamic contrast enhanced cone beam CT and double exponential curve fitting has been developed to analyze the renal functions for different functional regions. Future study will be performed to investigate the sensitivity of this technique in the detection

  15. Diagnostic performance of fluorodeoxyglucose-positron emission tomography/computed tomography of breast cancer in detecting axillary lymph node metastasis. Comparison with ultrasonography and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Monzawa, Shuichi; Adachi, Shuji; Suzuki, Kayo; Hirokaga, Koichi; Takao, Shintaro; Sakuma, Toshiko; Hanioka, Keisuke

    2009-01-01

    The purpose of this retrospective study was to evaluate the diagnostic performance of positron emission tomography/computed tomography (PET/CT) with fluorine-18-labeled 2-fluoro-2-deoxy-D-glucose (FDG) in comparison with that of ultrasonography and contrast-enhanced computed tomography (CT) in detecting axillary lymph node metastasis in patients with breast cancer. Fifty patients with invasive breast cancer were recruited. They had received no neoadjuvant chemotherapy and underwent PET/CT, ultrasonography and contrast-enhanced CT before mastectomy. The clinical stage was I in 34 patients, II in 15 patients, and III in one patient. The images of these modalities were interpreted in usual practice before surgery and the diagnostic reports were reviewed for analysis. Sensitivity, specificity, positive predictive value, and negative predictive value of each modality were obtained taking histopathological results of axillary lymph node dissection or sentinel lymph node biopsy as the reference standard. Axillary lymph node metastasis was confirmed in 15 of 50 patients by histopathological studies. PET/CT identified lymph node metastasis in three of these 15 patients. The overall sensitivity and specificity, positive predictive value, and negative predictive value of PET/CT in the diagnosis of axillary lymph node metastasis were 20, 97, 75, and 74%, and those of ultrasonography were 33, 94, 71, and 77% and those of contrast-enhanced CT were 27, 97, 80, and 76%, respectively. PET/CT showed poor sensitivity and high specificity in the detection of axillary lymph node metastasis of breast cancer. Diagnostic performance of PET/CT was not superior to that of ultrasonography and contrast-enhanced CT. (author)

  16. 18F-Fluorodeoxyglucose PET/CT and dynamic contrast-enhanced MRI as imaging biomarkers in malignant pleural mesothelioma

    OpenAIRE

    Hall, D. O.; Hooper, C. E.; Searle, J.; Darby, M.; White, P.; Harvey, J. E.; Braybrooke, J. P.; Maskell, N. A.; Masani, V.; Lyburn, I. D.

    2018-01-01

    Purpose\\ud \\ud The purpose of this study was to compare the use of fluorine-18-fluorodeoxyglucose (18F-FDG) PET with computed tomography (CT) and dynamic contrast-enhanced (DCE) MRI to predict prognosis and monitor treatment in malignant pleural mesothelioma.\\ud \\ud Patients and methods\\ud \\ud 18F-FDG PET/CT and DCE-MRI studies carried out as part of the South West Area Mesothelioma Pemetrexed trial were used. 18F-FDG PET/CT and DCE-MRI studies were carried out before treatment, and after two...

  17. Sporadic insulinomas on volume perfusion CT: dynamic enhancement patterns and timing of optimal tumour-parenchyma contrast

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Liang; Xue, Hua-dan; Liu, Wei; Wang, Xuan; Sun, Hao; Li, Ping; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Wu, Wen-ming; Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)

    2017-08-15

    To assess enhancement patterns of sporadic insulinomas on volume perfusion CT (VPCT), and to identify timing of optimal tumour-parenchyma contrast. Consecutive patients who underwent VPCT for clinically suspected insulinomas were retrospectively identified. Patients with insulinomas confirmed by surgery were included, and patients with familial syndromes were excluded. Two radiologists evaluated VPCT images in consensus. Tumour-parenchyma contrast at each time point was measured, and timing of optimal contrast was determined. Time duration of hyperenhancement (tumour-parenchyma contrast >20 Hounsfield units, HU) was recorded. Perfusion parameters were evaluated. Three dynamic enhancement patterns were observed in 63 tumours: persistent hyperenhancement (hyperenhancement time window ≥10 s) in 39 (61.9%), transient hyperenhancement (hyperenhancement <10 s) in 19 (30.2%) and non-hyperenhancement in 5 (7.9%). Timing of optimal contrast was 9 s after abdominal aorta threshold (AAT) of 200 HU, with tumour-parenchyma contrast of 77.6 ± 57.2 HU. At 9 s after AAT, 14 (22.2%) tumours were non-hyperenhancing, nine of which had missed transient hyperenhancement. Insulinomas with transient and persistent hyperenhancement patterns had significantly increased perfusion. Insulinomas have variable enhancement patterns. Tumour-parenchyma contrast is time-dependent. Optimal timing of enhancement is 9 s after AAT. VPCT enables tumour detection even if the hyperenhancement is transient. (orig.)

  18. Application of low dose radiation and low concentration contrast media in enhanced CT scans in children with congenital heart disease.

    Science.gov (United States)

    Liu, Zhimin; Song, Lei; Yu, Tong; Gao, Jun; Zhang, Qifeng; Jiang, Ling; Liu, Yong; Peng, Yun

    2016-09-01

    The aim of this study was to explore the feasibility of using low dose radiation and low concentration contrast media in enhanced CT examinations in children with congenital heart disease. Ninety patients with congenital heart disease were randomly divided into three groups of 30 patients each who underwent contrast-enhanced cardiac scans on a Discovery CT750 HD scanner. Group A received 270 mg I/mL iodixanol, and group B received 320 mg I/mL iodixanol contrast media and was scanned with prospective ECG triggering mode. Group C received 320 mg I/mL iodixanol and was scanned with conventional retrospective ECG gating mode. The same weight-based contrast injection protocol was used for all three groups. Images were reconstructed using a 30% adaptive statistical iterative reconstruction (ASIR) algorithm and a 50% ASIR in groups A and B and a 30% ASIR in group C. The subjective and objective image quality evaluations, diagnostic accuracies, radiation doses and amounts of contrast media in the three groups were measured and compared. All images in the three groups met the diagnostic requirements, with the same diagnostic accuracy and image quality scores greater than 3 in a 4-point scoring system. However, ventricular enhancement and the objective noise, signal-to-noise ratio, contrast-to-noise ratio and subjective image quality scores in group C were better than those in groups A and B (all Pcontrast dose (14% lower than that of groups B and C). Enhanced CT scan images with low dose radiation and low concentration contrast media can meet the diagnostic requirements for examining children with congenital heart disease while reducing the potential risk of radiation damage and contrast-induced nephropathy. © 2016 John Wiley & Sons Ltd.

  19. Use of high concentration contrast media (HCCM): principles and rationale--body CT

    International Nuclear Information System (INIS)

    Brink, James A.

    2003-01-01

    Numerous complex pharmacokinetic interrelationships affect the use of contrast media for computed tomography (CT) imaging. The volume, concentration, and rate of injection, all affect the degree of enhancement that is achieved with an injection of contrast material. In addition, the injection technique, whether the contrast is infused with a constant injection rate (uniphasic injection) or whether the rate is altered during the injection (multiphasic injection) also affect the magnitude and duration of contrast enhancement. In body CT imaging, the liver poses unique challenges in managing the use of intravenous contrast material because of its dual blood supply and the need to complete imaging before equilibrium occurs between the intravascular and extravascular compartments. The magnitude of hepatic enhancement that is ultimately achieved is related primarily to the amount of iodinated contrast material that accumulates in the extravascular space within the target organ, independent of the speed of the CT scanner. The key determinant of the onset of the equilibrium phase is the injection duration. Given that a high injection flow rate (4-5 ml/s) is desirable for arterial phase imaging, the injection duration is maintained with use of an appropriate contrast volume. Thus, modifications of total iodine dose are best done with alterations in contrast concentration. The magnitude of arterial enhancement that is achieved is related to both the concentration and rate of contrast administration. The speed of the scanner determines its ability to record image data during the most advantageous time period, the peak of arterial enhancement. Thus, rapid imaging is particularly advantageous for optimal contrast use in CT angiography as well as in multiphasic imaging of the parenchymal organs

  20. Feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in lung cancer treatment planning

    International Nuclear Information System (INIS)

    Xiao Jianghong; Zhang Hong; Gong Youling; Fu Yuchuan; Tang Bin; Wang Shichao; Jiang Qingfeng; Li Ping

    2010-01-01

    Background and purpose: To investigate the feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in 3-dimensional conformal radiotherapy (3D-CRT), stereotactic body radiation therapy (SBRT) and intensity-modulated radiotherapy (IMRT) treatment planning for lung cancers, respectively. Materials and methods: Twelve patients with bulky lung tumors and 14 patients with small lung tumors were retrospectively analyzed. Each patient took two sets of CT in the same position with active breathing control (ABC) technique before and after intravenous contrast agent (CA) injections. Bulky tumors were planned with 3D-CRT, while SBRT plans were generated for patients with small tumors based on CT scans with intravenous CA. In addition, IMRT plans were generated for patients with bulky tumors to continue on a planning study. All plans were copied and replaced on the scans without intravenous CA. The radiation doses calculated from the two sets of CTs were compared with regard to planning volumes (PTV), the organ at-risk (OAR) and the lungs using Wilcoxon's signed rank test. Results: In comparisons for 3D-CRT plans, CT scans with intravenous CA reduced the mean dose and the maximum dose of PTV with significant differences (p 95 ) for targets, respectively (p < 0.05). There was no statistical significance for lung parameters between two sets of scans in SBRT plans and IMRT plans. Conclusions: The enhanced CT scans can be used for both target delineation and treatment planning in 3D-CRT. The dose difference caused by intravenous CA is small. But for SBRT and IMRT, the minimum irradiation dose in targets may be estimated to be increased up to 2.71% while the maximum dose may be estimated to be decreased up to 1.36%. However, the difference in dose distribution in most cases were found to be clinical tolerable.

  1. Preliminary study of single contrast enhanced dual energy heart imaging using dual-source CT

    International Nuclear Information System (INIS)

    Peng Jin; Zhang Longjiang; Zhou Changsheng; Lu Guangming; Ma Yan; Gu Haifeng

    2009-01-01

    Objective: To evaluate the feasibility and preliminary applications of single contrast enhanced dual energy heart imaging using dual-source CT (DSCT). Methods: Thirty patients underwent dual energy heart imaging with DSCT, of which 6 cases underwent SPECT or DSA within one week. Two experienced radiologists assessed image quality of coronary arteries and iodine map of myocardium. and correlated the coronary artery stenosis with the perfusion distribution of iodine map. Results: l00% (300/300) segments reached diagnostic standards. The mean score of image for all patients was 4.68±0.57. Mural coronary artery was present in 10 segments in S cases, atherosclerotic plaques in 32 segments in 12 cases, of which 20 segments having ≥50% stenosis, 12 segments ≤50% stenosis; dual energy CT coronary angiography was consistent with the DSA in 3 patients. 37 segmental perfusion abnormalities on iodine map were found in 15 cases, including 28 coronary blood supply segment narrow segment and 9 no coronary stenosis (including three negative segments in SPECD. Conclusion: Single contrast enhanced dual energy heart imaging can provide good coronary artery and myocardium perfusion images in the patients with appropriate heart rate, which has a potential to be used in the clinic and further studies are needed. (authors)

  2. 18F-FDG-PET/CT parameters as imaging biomarkers in oral cavity squamous cell carcinoma, is visual analysis of PET and contrast enhanced CT better than the numbers?

    Energy Technology Data Exchange (ETDEWEB)

    Kendi, A.Tuba, E-mail: ayse.kendi@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Corey, Amanda [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Magliocca, Kelly R. [Department of Pathology, Emory University, Atlanta, GA (United States); Nickleach, Dana C. [Biostatistics & Bioinformatics Shared Resource at Winship Cancer Institute of Emory University, Atlanta, GA (United States); Galt, James [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Switchenko, Jeffrey M. [Biostatistics & Bioinformatics Shared Resource at Winship Cancer Institute of Emory University, Atlanta, GA (United States); El-Deiry, Mark W.; Wadsworth, J. Trad [Otolaryngology Head and Neck Surgery, Emory University, Atlanta, GA (United States); Hudgins, Patricia A. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States); Saba, Nabil F. [Hematology Oncology, Winship Cancer Institute of Emory University, Atlanta, GA (United States); Schuster, David M. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA (United States)

    2015-06-15

    Highlights: • Highlights of our study were the significant association of higher T stage of oral cavity squamous cell carcinoma with PET/CT parameters. • This could be an important finding in cases where it is difficult to decide on T stage by CT only. • We found a significant association between ring/heterogeneous enhancement pattern of (either primary or nodal or both) oral cavity squamous cell carcinoma at contrast enhanced CT and poor prognosis. • This could be related to hypoxia, which is a known reason for therapy resistance. Hence therapies can be tailored in the feature depending on enhancement pattern on contrast enhanced CT. - Abstract: Purpose: This study was designed to seek associations between positron emission tomography/computed tomography (PET/CT) parameters, contrast enhanced neck computed tomography (CECT) and pathological findings, and to determine the potential prognostic value of PET/CT and CECT parameters in oral cavity squamous cell carcinoma (OCSCC). Materials and method: 36 OCSCC patients underwent staging PET/CT and 30/36 of patients had CECT. PET/CT parameters were measured for the primary tumor and the hottest involved node, including maximum, mean, and peak standardized uptake values (SUV max, SUV mean, and SUV peak), metabolic tumor volume (MTV), total lesion glycolysis (TLG), standardized added metabolic activity (SAM), and normalized standardized added metabolic activity (N SAM). Qualitative assessment of PET/CT and CECT were also performed. Pathological outcomes included: perineural invasion, lymphovascular invasion, nodal extracapsular spread, grade, pathologic T and N stages. Multivariable logistic regression models were fit for each parameter and outcome adjusting for potentially confounding variables. Multivariable Cox proportional hazards models were used for progression free survival (PFS), locoregional recurrence free survival (LRFS), overall survival (OS) and distant metastasis free survival (DMFS). Results: In

  3. 18F-FDG-PET/CT parameters as imaging biomarkers in oral cavity squamous cell carcinoma, is visual analysis of PET and contrast enhanced CT better than the numbers?

    International Nuclear Information System (INIS)

    Kendi, A.Tuba; Corey, Amanda; Magliocca, Kelly R.; Nickleach, Dana C.; Galt, James; Switchenko, Jeffrey M.; El-Deiry, Mark W.; Wadsworth, J. Trad; Hudgins, Patricia A.; Saba, Nabil F.; Schuster, David M.

    2015-01-01

    Highlights: • Highlights of our study were the significant association of higher T stage of oral cavity squamous cell carcinoma with PET/CT parameters. • This could be an important finding in cases where it is difficult to decide on T stage by CT only. • We found a significant association between ring/heterogeneous enhancement pattern of (either primary or nodal or both) oral cavity squamous cell carcinoma at contrast enhanced CT and poor prognosis. • This could be related to hypoxia, which is a known reason for therapy resistance. Hence therapies can be tailored in the feature depending on enhancement pattern on contrast enhanced CT. - Abstract: Purpose: This study was designed to seek associations between positron emission tomography/computed tomography (PET/CT) parameters, contrast enhanced neck computed tomography (CECT) and pathological findings, and to determine the potential prognostic value of PET/CT and CECT parameters in oral cavity squamous cell carcinoma (OCSCC). Materials and method: 36 OCSCC patients underwent staging PET/CT and 30/36 of patients had CECT. PET/CT parameters were measured for the primary tumor and the hottest involved node, including maximum, mean, and peak standardized uptake values (SUV max, SUV mean, and SUV peak), metabolic tumor volume (MTV), total lesion glycolysis (TLG), standardized added metabolic activity (SAM), and normalized standardized added metabolic activity (N SAM). Qualitative assessment of PET/CT and CECT were also performed. Pathological outcomes included: perineural invasion, lymphovascular invasion, nodal extracapsular spread, grade, pathologic T and N stages. Multivariable logistic regression models were fit for each parameter and outcome adjusting for potentially confounding variables. Multivariable Cox proportional hazards models were used for progression free survival (PFS), locoregional recurrence free survival (LRFS), overall survival (OS) and distant metastasis free survival (DMFS). Results: In

  4. TH-EF-BRA-04: Individually Optimized Contrast-Enhanced 4D-CT for Radiotherapy Simulation in Pancreatic Ductal Adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Choi, W; Xue, M; Lane, B; Patel, K; Regine, W; Wang, J; Chen, S; D’souza, W; Lu, W [University of Maryland School of Medicine, Baltimore, MD (United States); Kang, M [Kyungpook National University School of Medicine, Daegu (Korea, Republic of); Klahr, P [Philips Healthcare, Highland Heights, OH (United States)

    2016-06-15

    Purpose: To develop an individually optimized contrast-enhanced (CE) 4D-CT for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). Methods: Ten PDA patients were enrolled. Each underwent 3 CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT using test injection. Three physicians contoured the tumor and pancreatic tissues. We compared image quality scores, tumor volume, motion, tumor-to-pancreas contrast, and contrast-to-noise ratio (CNR) in the 3 CTs. We also evaluated interobserver variations in contouring the tumor using simultaneous truth and performance level estimation (STAPLE). Results: Average image quality scores for CE 3DCT and CE 4D-CT were comparable (4.0 and 3.8, respectively; P=0.47), and both were significantly better than that for 4D-CT (2.6, P<0.001). Tumor-to-pancreas contrast results were comparable in CE 3D-CT and CE 4D-CT (15.5 and 16.7 HU, respectively; P=0.71), and the latter was significantly higher than in 4D-CT (9.2 HU, P=0.03). Image noise in CE 3D-CT (12.5 HU) was significantly lower than in CE 4D-CT (22.1 HU, P<0.001) and 4D-CT (19.4 HU, P=0.005). CNRs were comparable in CE 3D-CT and CE 4DCT (1.4 and 0.8, respectively; P=0.23), and the former was significantly better than in 4D-CT (0.6, P = 0.04). Mean tumor volumes were smaller in CE 3D-CT (29.8 cm{sup 3}) and CE 4D-CT (22.8 cm{sup 3}) than in 4D-CT (42.0 cm{sup 3}), although these differences were not statistically significant. Mean tumor motion was comparable in 4D-CT and CE 4D-CT (7.2 and 6.2 mm, P=0.23). Interobserver variations were comparable in CE 3D-CT and CE 4D-CT (Jaccard index 66.0% and 61.9%, respectively) and were worse for 4D-CT (55.6%) than CE 3D-CT. Conclusion: CE 4D-CT demonstrated characteristics comparable to CE 3D-CT, with high potential for simultaneously delineating the tumor and quantifying tumor motion with a single scan. Supported in part by Philips Healthcare.

  5. {sup 18}F-FDG PET/contrast enhanced CT in the standard surveillance of high risk colorectal cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Jiménez Londoño, Germán Andrés, E-mail: gjimenez91@yahoo.com [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); García Vicente, Ana María [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Sánchez Pérez, Victoria [Department of Oncology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Jiménez Aragón, Fátima [Department of Radiology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); León Martin, Alberto [Investigation Unit, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Cano Cano, Juana María [Department of Oncology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Domínguez Ferreras, Esther [Department of Radiology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Gómez López, Ober Van [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Espinosa Arranz, Javier [Department of Oncology, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain); Soriano Castrejón, Ángel María [Department of Nuclear Medicine, Hospital General Universitario de Ciudad Real, Ciudad Real (Spain)

    2014-12-15

    Highlights: • We assessed the accuracy of FDG-PET/contrast enhanced CT (FDG-PET/ceCT) in the detection of unsuspected recurrence of colorectal cancer. In regard to our knowledge, no previous experience has been reported about the combined acquisition and interpretation of a FDG-PET/ceCT in the surveillance of colorectal cancer. • We designed a prospective study and performed an individual and combined assessment of both techniques (PET and ceCT), in a patient-based analysis and a lesion-based analysis. • The value of PET and ceCT was found to be similar in the detection of unsuspected recurrence of CRC in a patient-based analysis. The most interesting of our result, is that the combined assessment of PET/ceCT improves the accuracy in the lesion-based analysis. - Abstract: Objective: To assess the accuracy of FDG-PET/contrast enhanced CT (FDG-PET/ceCT) in the detection of unsuspected recurrence of colorectal cancer (CRC) in patients with high risk of relapse. Methods: Thirty-three patients (14 females and 19 males, mean age: 62, range: 41–78), with CRC in complete remission, were prospectively included. All patients underwent FDG-PET/ceCT (58 studies). FDG-PET/ceCT was requested in the surveillance setting, and performed following a standardized protocol. A portal venous phase CT scan was performed after the injection of iodinated contrast agent. An individual and combined assessment of both techniques (PET and ceCT) was performed. Concordant and discordant findings of PET, ceCT and FDG-PET/ceCT were compared in a patient-based and a lesion-based analysis. The final diagnosis, recurrence or disease free status (DFS), were established by histopathology or clinical/radiological follow-up of at least 6 months. Results: Seven out of 33 patients had a confirmed recurrence and the rest of patients had a DFS. In a patient-based analysis the sensitivity and specificity of PET, ceCT and PET/ceCT was of 86% and 88%, 86% and 92%, 86% and 85%, respectively. Attending to

  6. VALIDITY OF CONTRAST ENHANCED CT IN THE ASSESSMENT OF ACUTE PANCREATITIS AND ITS RELATED COMPLICATIONS

    Directory of Open Access Journals (Sweden)

    Mannivanan

    2016-03-01

    Full Text Available BACKGROUND In the earlier days, ultrasonogram was considered as one of the most important investigation for pancreatitis, later the clinicians started using cholangiography in acute pancreatitis, but today CT is considered as a gold standard test in the diagnosis of acute pancreatitis. Though the sensitivity of CT in diagnosing acute pancreatitis was not studied much particularly in a mild case, but a good-quality contrast enhanced CT demonstrates distinct pancreatic and peri-pancreatic abnormalities. AIM To assess the importance of computed tomography in diagnosing acute pancreatitis and its related complications. MATERIALS AND METHODS A prospective study was conducted on 150 patients with clinically suspected pancreatitis. CT was performed on all the patients with Siemens Spiral CT scanner Sensation 16 slice. Oral contrast of was 1000 mL given one hour prior to the scan in the form of taking 250 mL every 15 mins. The CT severity index (CTSI and the necrosis point scoring was used to assess the severity of acute pancreatitis. All the complications related to acute pancreatitis were also assessed. RESULTS The CT analysis in the detection of acute pancreatitis showed the sensitivity of 100% and the positive predictive value of 97.3%. The severity index of acute pancreatitis based on the CT imaging had shown that majority of the patients are with moderate (60.6% level of acute pancreatitis. The necrosis point scoring showed that 54.6% of the patients had necrosis involving less than 30% of the pancreas. Among the various complications detected by CECT the commonest were pleural effusion and ascites. CONCLUSION CECT is the most important gold standard technique both for diagnosis as well as for predicting the prognosis in acute pancreatitis. The clinicians should routinely send the patient for the CT imaging whenever there is a suspicion of pancreatitis clinically.

  7. Dynamic contrast-enhanced MR imaging in osteoid osteoma: relationships with clinical and CT characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Pottecher, P. [Hopital Lariboisiere, AP-HP, Department of Osteoarticular Radiology, Paris (France); Hopital du Bocage, Department of Vascular, Oncologic and Interventional Radiology, Dijon (France); Sibileau, E.; Hamze, B.; Parlier, C.; Laredo, J.D.; Bousson, V. [Hopital Lariboisiere, AP-HP, Department of Osteoarticular Radiology, Paris (France); Aho, S. [Hopital du Bocage, Hospital Hygiene and Epidemiology unit, Dijon (France)

    2017-07-15

    To correlate dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) features to clinical and computed tomography (CT) morphological features of osteoid osteoma (OO). Our institutional review board approved this retrospective study, waiving the need for informed consent. We included the 102 patients treated with interstitial laser ablation for histologically documented OO at our institution in 2008-2013. DCE-MRI variables were the time-enhancement pattern and rising slope (Slope{sub rise}) and CT variables were the bone and segment involved (OO{sub bone} and OO{sub segment,} respectively), OO location relative to the native cortex (OO{sub cortex}), nidus surface area, vessel sign, and largest neighboring-vessel diameter (Dmax{sub vessel}). Descriptive statistics and correlations linking DCE-MRI findings to clinical and CT characteristics were computed. DCE-MRI showed early arterial peak enhancement in 95 (93%) cases, with a mean Slope{sub rise} of 9.30 ± 8.10. CT visualized a vessel sign in 84 (82%) cases with a mean Dmax{sub vessel} of 1.10 ± 0.60 mm. By univariate analysis, Slope{sub rise} correlated significantly with pain duration and Dmax{sub vessel} (r = 0.30, P = 0.003; and r = 0.22, P = 0.03; respectively). Analysis of variance showed that Slope{sub rise} correlated significantly with OO{sub bone} (P < 0.001), with a steeper slope for OOs located in short or flat bones. This study suggests more abundant vascularization of OOs with long-lasting pain and location on short or flat bones. (orig.)

  8. Quantitative contrast-enhanced CT attenuation evaluation of osseous metastases following chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Simeone, F.J.; Torriani, Martin; Bredella, Miriam A. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States)

    2017-10-15

    Osseous metastases often undergo an osteoblastic healing response following chemotherapy. The purpose of our study was to demonstrate the quantitative CT changes in attenuation of osseous metastases before and after chemotherapy. Our study was IRB approved and HIPAA compliant. Our cohort consisted of 86 consecutive cancer patients with contrast-enhanced CTs before and 14 ± 2 (12-25) months after initiation of chemotherapy (60 ± 11 years, 36 males, 50 females). The average and maximum metastasis attenuations were measured in Hounsfield units (HU) by two readers. Treatment effects were assessed using paired t-tests and Fisher exact tests. Intraclass correlation coefficients (ICCs) were calculated. Patient records were reviewed to determine the patient's clinical status (worse, unchanged, or improved) at the time of follow-up CT. The distribution of lesion types was as follows: lytic (30/86, 35%), blastic (43/86, 50%), and mixed lytic-blastic (13/86, 15%). There was a significant increase in average and maximum CT attenuation of metastases following chemotherapy for all patients, which remained statistically significant when stratified by lesion type, clinical status (worsening or improving/stable), cancer type (breast, lung), and radiation therapy (P < 0.05). In a subgroup of patients whose osseous metastases decreased in average attenuation (14/86, 16%), more patients had a worse clinical status (11/14, 79%) (P = 0.02). ICC was almost perfect for average attenuation and substantial for maximum attenuation. Quantitative assessment of osseous metastatic disease using CT attenuation measurements demonstrated a statistically significant increase in attenuation more than 12 months after initiation of chemotherapy. (orig.)

  9. Patterns of uterine enhancement with helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, H.; Loyer, E.M.; Charnsangavej, C. [Department of Diagnostic Radiology, Box 57, The University of Texas, M.D. Anderson Cancer Center, 1515 Holcombe Blvd. Houston, TX 77030 (United States); Minami, M. [Department of Radiology, Faculty of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo 113 (Japan)

    1998-10-01

    Objective: The purpose of this study was to evaluate the enhancement characteristics of the normal uterine body and cervix using dynamic contrast-enhanced helical CT. Methods: Thirty-eight women scheduled for pelvic CT for non-gynecologic malignancies underwent dynamic contrast-enhanced helical CT of the pelvis. Data acquisition was during the arterial phase (30-45 s after the start of injection), the parenchymal phase (90-120 s after the start of injection), and delayed phase (3-9 min after the start of injection). The images were evaluated by four radiologists for the pattern of myometrial and cervical enhancement. Correlation was made with the age and menstrual status of the patients. Results: In the uterine body, three types of enhancement were observed. Type 1 enhancement, seen in 16 patients (42%), was characterized by the visualization of a subendometrial zone of enhancement, 30-120 s after the start of injection. Eight of these patients also showed an enhancing zone in the outer myometrium. Both zones were transitory, and in all cases, the uterus became homogeneous in the delayed phase. This pattern was seen predominantly in premenopausal women with a mean age of 34 years. Type 2 enhancement, seen in 17 cases (45%), was defined by the absence of subendometrial enhancement in the early phase. Enhancement was either diffuse from the outset or originated in the outer myometrium. This pattern was seen nearly equally in premenopausal and postmenopausal women with a mean age of 40 years. Type 3 enhancement was seen in five postmenopausal patients (13%) with a mean age of 53 years and was characterized by faint diffuse enhancement. In the cervix, a zonal pattern of enhancement defining inner and outer stroma was seen in 23 patients (61%). Fifteen patients were premenopausal and eight were postmenopausal. Conclusion: In this study, we have shown a transitory zonal distribution of the contrast in the myometrium and cervix using dynamic contrast-enhanced helical CT

  10. Patterns of uterine enhancement with helical CT

    International Nuclear Information System (INIS)

    Kaur, H.; Loyer, E.M.; Charnsangavej, C.; Minami, M.

    1998-01-01

    Objective: The purpose of this study was to evaluate the enhancement characteristics of the normal uterine body and cervix using dynamic contrast-enhanced helical CT. Methods: Thirty-eight women scheduled for pelvic CT for non-gynecologic malignancies underwent dynamic contrast-enhanced helical CT of the pelvis. Data acquisition was during the arterial phase (30-45 s after the start of injection), the parenchymal phase (90-120 s after the start of injection), and delayed phase (3-9 min after the start of injection). The images were evaluated by four radiologists for the pattern of myometrial and cervical enhancement. Correlation was made with the age and menstrual status of the patients. Results: In the uterine body, three types of enhancement were observed. Type 1 enhancement, seen in 16 patients (42%), was characterized by the visualization of a subendometrial zone of enhancement, 30-120 s after the start of injection. Eight of these patients also showed an enhancing zone in the outer myometrium. Both zones were transitory, and in all cases, the uterus became homogeneous in the delayed phase. This pattern was seen predominantly in premenopausal women with a mean age of 34 years. Type 2 enhancement, seen in 17 cases (45%), was defined by the absence of subendometrial enhancement in the early phase. Enhancement was either diffuse from the outset or originated in the outer myometrium. This pattern was seen nearly equally in premenopausal and postmenopausal women with a mean age of 40 years. Type 3 enhancement was seen in five postmenopausal patients (13%) with a mean age of 53 years and was characterized by faint diffuse enhancement. In the cervix, a zonal pattern of enhancement defining inner and outer stroma was seen in 23 patients (61%). Fifteen patients were premenopausal and eight were postmenopausal. Conclusion: In this study, we have shown a transitory zonal distribution of the contrast in the myometrium and cervix using dynamic contrast-enhanced helical CT

  11. Is hepatotropic contrast enhanced MR a more effective method in differential diagnosis of hemangioma than multi-phase CT and unenhanced MR?

    Directory of Open Access Journals (Sweden)

    Markiet Karolina

    2011-04-01

    Full Text Available Abstract Background Cavernous hemangiomas are the most frequent neoplasms of the liver and in routine clinical practice they often need to be differentiated from malignant tumors and other benign focal lesions. The purpose of this study is to evaluate whether diagnostic accuracy of magnetic resonance imaging (MRI of hepatic hemangiomas, showing atypical pattern on US, improves with the use of Gd-BOPTA in comparison with contrast-enhanced multi-phase computed tomography (CT. Methods 178 consecutive patients with ambiguous hepatic masses showing atypical hyperechoic pattern on grey-scale US, underwent unenhanced and contrast-enhanced multi-phase multi-detector CT and MR (1.5T with the use of liver-specific contrast medium gadobenate dimeglumine (Gd-BOPTA. After intravenous contrast administration arterial (HAP, venous-portal (PVP, equilibrium phases (EP both in CT and MR and additionally hepatobiliary phase (HBP in MR were obtained. 398 lesions have been detected including 99 hemangiomas and 299 other lesions. Results In non-enhanced MDCT examination detection of hemangiomas was characterized by sensitivity of 76%, specificity of 90%, PPV of 71%, NPV of 92% and accuracy of 86%. Non-enhanced MR examination showed sensitivity of 98%, specificity of 99%, PPV of 99%, NPV of 99% and accuracy of 99%. After intravenous administration of contrast medium in MR the mentioned above parameters did not increase significantly. Conclusion Gd-BOPTA-enhanced MR in comparison with unenhanced MRI does not improve diagnostic accuracy in discriminating hemangiomas that show non-specific appearance in ultrasound examination. Unenhanced MR as a method of choice should directly follow US in course of diagnostic algorithm in differentiation of hemangiomas from other liver tumors.

  12. Value of fusion of PET and MRI in the detection of intra-pelvic recurrence of gynecological tumor: comparison with 18F-FDG contrast-enhanced PET/CT and pelvic MRI.

    Science.gov (United States)

    Kitajima, Kazuhiro; Suenaga, Yuko; Ueno, Yoshiko; Kanda, Tomonori; Maeda, Tetsuo; Makihara, Natsuko; Ebina, Yasuhiko; Yamada, Hideto; Takahashi, Satoru; Sugimura, Kazuro

    2014-01-01

    To evaluate the diagnostic value of retrospective image fusion from pelvic magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose positron emission tomography (PET) in detecting intra-pelvic recurrence of gynecological tumor. Thirty patients with a suspicion of recurrence of gynecological malignancy underwent inline contrast-enhanced PET/computed tomography (CT) and pelvic contrast-enhanced MRI for restaging. Diagnostic performance about the local recurrence, pelvic lymph node and bone metastasis and peritoneal lesion of PET/low-dose non-enhanced CT (PET/ldCT), PET/full-dose contrast-enhanced CT (PET/ceCT), contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) were evaluated by two experienced readers. Final diagnoses were obtained by histopathological examinations, radiological imaging and clinical follow-up for at least 6 months. McNemar test was employed for statistical analysis. Documented positive locally recurrent disease, pelvic lymph node and bone metastases, and peritoneal dissemination were present in 53.3, 26.7, 10.0, and 16.7%, respectively. Patient-based sensitivity for detecting local recurrence, pelvic lymph node and bone metastasis and peritoneal lesion were 87.5, 87.5, 100 and 80.0%, respectively, for fused PET/MRI, 87.5, 62.5, 66.7 and 60.0%, respectively, for contrast-enhanced MRI, 62.5, 87.5, 66.7 and 80.0%, respectively, for PET/ceCT, and 50.0, 87.5, 66.7 and 60.0%, respectively, for PET/ldCT. The sensitivity of diagnosing local recurrence by fused PET/MRI was significantly better than that of PET/ldCT (p=0.041). The patient-based sensitivity, specificity and accuracy for the detection of intra-pelvic recurrence/metastasis were 91.3, 100 and 93.3% for fused PET/MRI, 82.6, 100 and 86.7% for contrast-enhanced MRI, 82.6, 100 and 86.7% for PET/ceCT and 78.3, 85.7 and 80.0% for PET/ldCT. Fused PET/MRI combines the individual advantages of MRI and PET, and is a valuable technique for assessment of intra

  13. Relationship between the natural history of chronic subdural hematoma and enhancement of the inner membrane on post-contrast CT scan

    International Nuclear Information System (INIS)

    Nakaguchi, Hiroshi; Yoshimasu, Norio; Tanishima, Takeo

    2003-01-01

    The purpose of this study was to determine the features and natural history of the inner membrane in CSDH (chronic subdural hematoma) patients using pre- and post-contrast CT scans. Twenty-four patients with CSDH (28 hematomas) who underwent pre- and post-contrast CT scanning prior to surgery ware studied. CSDH was classified according to the internal architecture as the homogeneous (HM) type, the laminar (LM) type, the separated (SP) type, and the trabecular (TR) type. For each type, the enhancement of the inner membrane, the outer membrane, and trabeculae was evaluated. Enhancement of the inner membrane develops as the stage of CSDH progresses. Although the inner membrane was not enhanced in the HM type, it was enhanced in almost all of the patients with the other types (p <0.0001). In 13% of patients with the LM type, 29% with the SP type, and 40% with the TR type, the inner membrane was moderately or markedly enhanced. The outer membrane was not thickened in any patient. In 88% of the patients who had contralateral hemiparesis on admission and 42% of those who did not have hemiparesis, the inner membrane was clearly enhanced (p=0.0166). This indicated that blood flow to the inner membrane from the pia matter induced hypoperfusion of the brain parenchyma beneath the hematoma in addition to the effect of direct compression. Contrast CT scanning may be useful for diagnosing the extent of enlargement of the inner membrane, predicting the risk of local brain damage, and evaluating the stage in the natural history of CSDH. (author)

  14. Relationship between the natural history of chronic subdural hematoma and enhancement of the inner membrane on post-contrast CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Nakaguchi, Hiroshi; Yoshimasu, Norio [Teraoka Memorial Hospital, Shinichi, Hiroshima (Japan); Tanishima, Takeo [Tokyo Kosei Nenkin Hospital (Japan)

    2003-02-01

    The purpose of this study was to determine the features and natural history of the inner membrane in CSDH (chronic subdural hemotoma) patients using pre- and post-contrast CT scans. Twenty-four patients with CSDH (28 hematomas) who underwent pre- and post-contrast CT scanning prior to surgery ware studied. CSDH was classified according to the internal architecture as the homogeneous (HM) type, the laminar (LM) type, the separated (SP) type, and the trabecular (TR) type. For each type, the enhancement of the inner membrane, the outer membrane, and trabeculae was evaluated. Enhancement of the inner membrane develops as the stage of CSDH progresses. Although the inner membrane was not enhanced in the HM type, it was enhanced in almost all of the patients with the other types (p <0.0001). In 13% of patients with the LM type, 29% with the SP type, and 40% with the TR type, the inner membrane was moderately or markedly enhanced. The outer membrane was not thickened in any patient. In 88% of the patients who had contralateral hemiparesis on admission and 42% of those who did not have hemiparesis, the inner membrane was clearly enhanced (p=0.0166). This indicated that blood flow to the inner membrane from the pia matter induced hypoperfusion of the brain parenchyma beneath the hematoma in addition to the effect of direct compression. Contrast CT scanning may be useful for diagnosing the extent of enlargement of the inner membrane, predicting the risk of local brain damage, and evaluating the stage in the natural history of CSDH. (author)

  15. The impact of the PET/CT in comparison with the same day contrast enhanced CT in breast cancer management

    International Nuclear Information System (INIS)

    Piperkova, E.; Raphael, B.; Altinyay, M.; Castellon, I.; Libes, R.; Abdel-Dayem, H.

    2006-01-01

    Full text: The aim of this study is to evaluate the impact of 18F-fluorodeoxyglucose FDG positron emission tomography with fused computerized tomography (PET/CT) in comparison with the same day contrast enhanced CT (CE-CT) in the breast cancer (BC) management. 68 studies in 48 BC patients, 8 for initial and 60 for restaging disease, after surgery, radiation/chemotherapy, for radiation therapy planning or evaluating treatment response were included. All patients underwent whole body PET/CT for diagnostic purposes followed by CE-CT diagnostic scans of selected body regions. PET/CT was performed approximately 90 minutes following 10-15 mCi of 18F-FDG on a GE Discovery PET/CT system. CT part acquired with low dose X-ray for localization and attenuation correction. The CE-CT was performed according to departmental protocol. Out of a total of 235 lesions in 68 PET/CT and CE-CT studies, 189 were concordant between PET/CT and CE-CT. However, there were 46 discordant lesions, which were verified by either follow-up or biopsy. PET/CT correctly identified 25 (True Positive-TP). CE-CT identified 2 TP lesions missed by PET/CT (False negative): one liver metastasis with necrosis, which is a known non-avid FDG, the other was a missed abdominal metastatic node, which did not change staging or treatment. PET/CT incorrectly identified 2 lesions (False Positive) while CE-CT incorrectly identified 17 FP. For evaluating treatment response in 40 follow up studies PET/CT reported complete response in 15, partial response in 11, stable disease in 2, progression in 5, and free of disease following surgery - in 7. The CE-CT described progression of the disease in 1 PET/CT true negative study and no progression in 2 TP PET/CT studies. In this study, PET/CT played more important role than CECT scans alone and provided an impact on the management of BC patients

  16. Volumetric dynamic contrast enhanced Computed Tomography (DCE-CT) for preoperative assessment of the vascularity of spinal metastases

    DEFF Research Database (Denmark)

    Lauridsen, Carsten Ammitzbøl

    Purpose To investigate the feasibility of measuring and grading the vascularity of spinal metastases using dynamic contrast enhanced CT (DCE-CT). Materials and methods Prior to surgical treatment of symptomatic metastatic spinal cord compression, 20 patients were examined using DCE-CT. The 320......–detector row CT scanner allowed a volumetric acquisition over a range of 16 cm, covering three to four vertebrae. Image analysis was performed at a dedicated workstation, encompassing quantitative and qualitative measurement of the arterial flow (AF) in mL/min/100mL of the vertebrae. The perfusion values...... were analysed using a single input, maximum slope model. The AF assessed by DCE-CT of affected and non-affected vertebrae will be compared, and furthermore, the correlation between AF and intraoperative blood loss will be examined. Results Preliminary results for 5 patients: In two patients the AF...

  17. Additional value of FDG PET/CT to contrast-enhanced CT in the differentiation between benign and malignant intraductal papillary mucinous neoplasms of the pancreas with mural nodules

    International Nuclear Information System (INIS)

    Takanami, Kentaro; Hiraide, Tomomichi; Tsuda, Masashi; Nakamura, Yausuhiro; Kaneta, Tomohiro; Takase, Kei; Takahashi, Shoki; Fukuda, Hiroshi

    2011-01-01

    This study aimed at determining the additional value of F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT to contrast-enhanced CT in the differentiation between benign and malignant intraductal papillary mucinous neoplasms (IPMNs) of the pancreas with mural nodules. This retrospective review of medical records was approved by our institutional review board. The preoperative PET/CT images of 16 non-diabetic patients with surgically proven IPMN, where mural nodules of 3 mm or larger were shown by preoperative contrast-enhanced CT, were retrospectively evaluated. The 16 patients were divided into two groups: 7 patients with benign IPMN [adenoma (n=1) and borderline tumor (n=6)] and 9 patients with malignant IPMN [carcinoma in situ (CIS) (n=8) and invasive carcinoma (n=1)]. Nuclear medicine physician blinded to the pathologic assessment of malignancy of IPMN set a spherical volume of interest (VOI) over the mural nodules on PET/CT images and recorded the peak standardized uptake value (SUV max ) in the VOI, referring the contrast-enhanced CT images. Statistical differences in the size of mural nodule, the diameter of main pancreatic duct (MPD), and SUV max of the tumors between benign IPMNs and malignant IPMNs were compared using the Mann-Whitney U test. Statistical significance was set at p max of the malignant IPMNs with mural nodules of 3 mm or larger was higher than that of benign IPMNs (2.7±0.6 vs. 1.9±0.3, p<0.01). Meanwhile, there was no significant difference in mural nodule diameter and MPD diameter between the two groups. FDG PET/CT showed an excellent diagnostic accuracy for the differentiation between malignant and benign IPMNs with mural nodules: the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy in malignant IPMN with mural nodule of FDG PET/CT were 77.8, 100, 100, 77.8, and 87.5 for the cutoff value of 2.3; and 100, 57.1, 75.0, 100, and 81.3 for the cutoff value of 2

  18. A contrast enhancement and scanning techniques for CT angiography of head and neck. One phase injection method for simultaneous imaging of vessels and tumor

    International Nuclear Information System (INIS)

    Morita, Yasuhiko; Indo, Hiroko; Noikura, Takenori

    1999-01-01

    We report on a method of CT-Angiography useful for examining lesion of the head and neck using three-dimensional images and measured CT value. This study focused on some of the important blood vessels in the head and neck. The aim of this method was to obtain high-contrast enhancement for both vessels and tumors at same time. A total amount of 100 ml nonionic contrast media (Omnipaque 240, 240 mg iodine per milliliter, Daiichi seiyaku, Tokyo, Japan) was injected intravenously with a flow of 1.5 ml/sec. Spiral scans, 24 rotations with 24 seconds, were started at a time when remaining amount of contrast media had become 30 to 20 ml. All CT scans were performed using double speed spiral scan technique with a slice thickness of 2 to 3 mm and table speeds from 3 to 5 mm/rotation. The patients populations consisted of 9 men and 6 women who ranged in age from 37 to 85 years. Sixteen CT-angiography were performed according to this method. Mean CT values of major blood vessels were measured in order to find out threshold at the level of submandibular gland in 13 examinations for 12 subjects. Important vessels like the common, internal, and the external artery, internal and external jugular vein were clearly visible in all subjects. Three dimensional images of these vessels could also be reconstructed for 15 of the subjects. Mean CT values were 211 Hounsfield units (HU) and 209 HU for the right and left internal carotid artery, respectively, and 204 HU and 206 HU for the right and left external carotid artery, respectively. Mean CT values for right and left internal jugular vein were 195 HU and 194 HU respectively. Measured CT values at each important blood vessels showed this method could yields acceptable enhancements. Good enhancement effect of tumor and blood vessels in the same scan seems to be mutually incompatible. One very important trade-off is the early enhancement effect at blood vessels versus the late enhancement effect at tumors. The other important trade

  19. Unusual presentation of a pancreatic insulinoma in helical CT and dynamic contrast-enhanced MR imaging: case report

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias, A.; Arias, M.; Brasa, J. [Unidad de Resonancia Magnetica (Medtec), Hospital Xeral-Cies, Vigo (Spain); Casal, M. [Unidad de Radiologia Intervencionista, Hospital Xeral-Cies, Vigo (Spain); Paramo, C. [Servicio de Endocrinologia, Hospital Xeral-Cies, Vigo (Spain); Fiano, C. [Servicio de Anatomia Patologica, Hospital Xeral-Cies, Vigo (Spain)

    2001-06-01

    Insulinomas are pancreatic neoplasms that can be radiologically characterized typically because of their tendency to present intense and early contrast enhancement with a wash-out phenomenon. In this sense, we report an unusual case of a hypovascular solid pancreatic insulinoma confirmed with surgery and pathologic analysis, in a patient with normal serum insulin levels. In the two-phase helical CT, the mass behaved as a hypodense lesion with respect to the surrounding pancreatic parenchyma during the arterial phase and as a hypointense lesion during the dynamic contrast-enhanced MR imaging. Pathologic examination demonstrated a hypercellular tumor with poor vascularization of intervening stroma which showed prominent amyloid deposits. (orig.)

  20. Unusual presentation of a pancreatic insulinoma in helical CT and dynamic contrast-enhanced MR imaging: case report

    International Nuclear Information System (INIS)

    Iglesias, A.; Arias, M.; Brasa, J.; Casal, M.; Paramo, C.; Fiano, C.

    2001-01-01

    Insulinomas are pancreatic neoplasms that can be radiologically characterized typically because of their tendency to present intense and early contrast enhancement with a wash-out phenomenon. In this sense, we report an unusual case of a hypovascular solid pancreatic insulinoma confirmed with surgery and pathologic analysis, in a patient with normal serum insulin levels. In the two-phase helical CT, the mass behaved as a hypodense lesion with respect to the surrounding pancreatic parenchyma during the arterial phase and as a hypointense lesion during the dynamic contrast-enhanced MR imaging. Pathologic examination demonstrated a hypercellular tumor with poor vascularization of intervening stroma which showed prominent amyloid deposits. (orig.)

  1. SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, W; Xue, M; Patel, K; Regine, W; Wang, J; D’Souza, W; Lu, W [University of Maryland School of Medicine, Baltimore, MD (United States); Kang, M [University of Maryland School of Medicine, Baltimore, MD (United States); Yeungnam University Medical Center, Daegu, Daegu (Korea, Republic of); Klahr, P [Philips Healthcare, Highland Heights, OH (United States)

    2015-06-15

    Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.

  2. A study of plaque vascularization and inflammation using quantitative contrast-enhanced US and PET/CT

    International Nuclear Information System (INIS)

    Hjelmgren, Ola; Johansson, Lars; Prahl, Ulrica; Schmidt, Caroline; Fredén-Lindqvist, Johan; Bergström, Göran M.L.

    2014-01-01

    Background: Contrast-enhanced ultrasound (CEUS) is an in vivo methodology to quantify carotid plaque vascularization. Increased metabolism in plaques, measured as FDG uptake in PET/CT examination, has been associated with markers of inflammation in histological samples. In this study, we tested the association between FDG uptake and vascularization measured by CEUS to assess whether CEUS can be used as an in vivo marker of plaque vulnerability. Methods: After informed consent, subjects aged >60 years with carotid plaque height exceeding 2.5 mm were recruited. CEUS was performed and analyzed using earlier described protocol and software, Contrast Quantification Program, which calculates the fraction of the plaque being contrast positive (CQP value). PET/CT examination was performed within 3 months of CEUS (median time 7 days). PET/CT images were acquired 90 min after FDG injection (2.7 MBq/kg). FDG uptake was measured as tissue background index (TBI), calculated using Spearman's rho as mean standard uptake value (SUV) of the plaque divided by mean SUV in the jugular vein (mean of 7 measuring points). Local ethics committee approved the study. Results: We recruited 13 subjects (5 women) with a mean age of 71 years, 6 had a history of stroke or TIA, 1 had a history of ipsilateral stroke. CQP values showed a significant, positive correlation with TBI of carotid plaques, r = 0.67, p < 0.02. Conclusions: Plaque vascularization measured by CEUS correlates positively with FDG uptake measured by PET/CT in humans. This indicates an association between vascularization and inflammation and/or hypoxia, supporting the use of CEUS as a non-invasive method to detect plaque vulnerability

  3. A study of plaque vascularization and inflammation using quantitative contrast-enhanced US and PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hjelmgren, Ola, E-mail: ola.hjelmgren@wlab.gu.se [Institute of Medicine, Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Clinical Physiology, Gothenburg (Sweden); Sahlgrenska University Hospital, Department of Clinical Physiology, Gothenburg (Sweden); Johansson, Lars, E-mail: lars.johansson@radiol.uu.se [Uppsala University, Department of Radiology, Uppsala (Sweden); Prahl, Ulrica, E-mail: ulrica-prahl-gullberg@wlab.gu.se [Institute of Medicine, Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Clinical Physiology, Gothenburg (Sweden); Schmidt, Caroline, E-mail: caroline.schmidt@wlab.gu.se [Institute of Medicine, Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Clinical Physiology, Gothenburg (Sweden); Fredén-Lindqvist, Johan, E-mail: johan.freden-lindqvist@vgregion.se [Sahlgrenska University Hospital, Department of Clinical Physiology, Gothenburg (Sweden); Bergström, Göran M.L., E-mail: goran.bergstrom@hjl.gu.se [Institute of Medicine, Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Clinical Physiology, Gothenburg (Sweden); Sahlgrenska University Hospital, Department of Clinical Physiology, Gothenburg (Sweden)

    2014-07-15

    Background: Contrast-enhanced ultrasound (CEUS) is an in vivo methodology to quantify carotid plaque vascularization. Increased metabolism in plaques, measured as FDG uptake in PET/CT examination, has been associated with markers of inflammation in histological samples. In this study, we tested the association between FDG uptake and vascularization measured by CEUS to assess whether CEUS can be used as an in vivo marker of plaque vulnerability. Methods: After informed consent, subjects aged >60 years with carotid plaque height exceeding 2.5 mm were recruited. CEUS was performed and analyzed using earlier described protocol and software, Contrast Quantification Program, which calculates the fraction of the plaque being contrast positive (CQP value). PET/CT examination was performed within 3 months of CEUS (median time 7 days). PET/CT images were acquired 90 min after FDG injection (2.7 MBq/kg). FDG uptake was measured as tissue background index (TBI), calculated using Spearman's rho as mean standard uptake value (SUV) of the plaque divided by mean SUV in the jugular vein (mean of 7 measuring points). Local ethics committee approved the study. Results: We recruited 13 subjects (5 women) with a mean age of 71 years, 6 had a history of stroke or TIA, 1 had a history of ipsilateral stroke. CQP values showed a significant, positive correlation with TBI of carotid plaques, r = 0.67, p < 0.02. Conclusions: Plaque vascularization measured by CEUS correlates positively with FDG uptake measured by PET/CT in humans. This indicates an association between vascularization and inflammation and/or hypoxia, supporting the use of CEUS as a non-invasive method to detect plaque vulnerability.

  4. Diffusible iodine-based contrast-enhanced computed tomography (diceCT): an emerging tool for rapid, high-resolution, 3-D imaging of metazoan soft tissues.

    Science.gov (United States)

    Gignac, Paul M; Kley, Nathan J; Clarke, Julia A; Colbert, Matthew W; Morhardt, Ashley C; Cerio, Donald; Cost, Ian N; Cox, Philip G; Daza, Juan D; Early, Catherine M; Echols, M Scott; Henkelman, R Mark; Herdina, A Nele; Holliday, Casey M; Li, Zhiheng; Mahlow, Kristin; Merchant, Samer; Müller, Johannes; Orsbon, Courtney P; Paluh, Daniel J; Thies, Monte L; Tsai, Henry P; Witmer, Lawrence M

    2016-06-01

    Morphologists have historically had to rely on destructive procedures to visualize the three-dimensional (3-D) anatomy of animals. More recently, however, non-destructive techniques have come to the forefront. These include X-ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard-tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT-based research is the use of chemical agents to render visible, and differentiate between, soft-tissue structures in X-ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine-based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine-based, contrast-enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting-edge applications of diffusible iodine-based contrast-enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward. © 2016 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  5. Dual-energy CT in the assessment of mediastinal lymph nodes: Comparative study of virtual non-contrast and true non-contrast images

    International Nuclear Information System (INIS)

    Yoo, Seon Young; Kim, Yoo Kyung; Cho, Hyun Hae; Choi, Mi Joo; Shim, Sung Shine; Lee, Jeong Kyong; Baek, Seung Yon

    2013-01-01

    To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation ≤ the aorta; 1, > the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0.612). The mean absolute difference was 7.8 ± 7.6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65.2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (κ value, 0.335). Five of 16 nodes (31.3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0.455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0.245). VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.

  6. Dual-energy CT in the assessment of mediastinal lymph nodes: Comparative study of virtual non-contrast and true non-contrast images

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seon Young; Kim, Yoo Kyung; Cho, Hyun Hae; Choi, Mi Joo; Shim, Sung Shine; Lee, Jeong Kyong; Baek, Seung Yon [School of Medicine, Ewha Womans University, Seou (Korea, Republic of)

    2013-06-15

    To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation ≤ the aorta; 1, > the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0.612). The mean absolute difference was 7.8 ± 7.6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65.2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (κ value, 0.335). Five of 16 nodes (31.3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0.455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0.245). VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.

  7. Dual-energy CT in the assessment of mediastinal lymph nodes: comparative study of virtual non-contrast and true non-contrast images.

    Science.gov (United States)

    Yoo, Seon Young; Kim, Yookyung; Cho, Hyun Hae; Choi, Mi Joo; Shim, Sung Shine; Lee, Jeong Kyong; Baek, Seung Yon

    2013-01-01

    To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation ≤ the aorta; 1, > the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0.612). The mean absolute difference was 7.8 ± 7.6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65.2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (κ value, 0.335). Five of 16 nodes (31.3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0.455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0.245). VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.

  8. Malignant focal hepatic lesions complicating underlying liver disease: dual-phase contrast-enhanced spiral CT sensitivity and specificity in orthotopic liver transplant patients

    International Nuclear Information System (INIS)

    Mortele, K.J.; De Keukeleire, K.; Praet, M.; Van Vlierberghe, H.; Hemptinne, B. de; Ros, P.R.

    2001-01-01

    The aim of this study was to determine the accuracy of contrast-enhanced biphasic spiral CT as a screening tool in the preoperative evaluation of orthotopic liver transplant (OLT) patients. Spiral-CT examinations were performed before liver transplantation in 53 patients. Scans were retrospectively reviewed and compared with pathologic findings in fresh-sectioned livers. When findings between spiral CT and pathology were discordant, formalized livers were reexamined with lesion-by lesion evaluation. Fresh pathologic evaluation revealed 23 liver lesions (16 HCC, 7 macro-regenerative nodules). Malignancy was identified in 13 of 53 patients (24.5%). Pre-transplantation spiral CT depicted 27 liver lesions (23 HCC, 4 macro-regenerative nodules). Malignancy was suspected in 14 patients (26.4%). In 10 of 53 (18.9%), spiral CT and pathologic evaluation were discordant. Subsequent retrospective pathologic evaluation showed malignancy in 4 additional patients. Spiral CT compared with the retrospective pathologic findings revealed 36 real-negative, 14 real-positive, 0 false-positive, and 3 false-negative patients with malignancy. Sensitivity and specificity of spiral CT in detection of malignancy was 82 and 100%, respectively. Contrast-enhanced biphasic spiral CT is an accurate technique in the evaluation of patients preceding OLT. Routine fresh-sectioned liver pathologic findings are not as sensitive as previously estimated. (orig.)

  9. The analysis of the contrast enhanced lesions on cerebro-vascular diseases

    International Nuclear Information System (INIS)

    Terada, Tomoaki; Nishiguchi, Takashi; Hyoutani, Genhachi; Miyamoto, Kazuki; Komai, Norihiko

    1989-01-01

    The contrast enhancement of cerebro-vascular diseases on CT is thought to be due to the increase of the cerebral blood volume (CBV) and/or the disruption of the blood brain barrier (BBB). However, it is difficult to differentiate these two conditions only by contrast enhanced CT. We employed dynamic CT (DCT) to analyse these lesions with respect to the patterns of time-density curve and peak height (PH) of the curve upon the theoretical basis that flattening of the latter part of the time-density curve reflected the degree of BBB disruption and PH reflected the CBV. In all cases of hypertensive intracerebral hemorrhage (11 cases), the contrast enhanced lesion around the hematoma showed marked BBB disruption according to the results of DCT. In 11 cases of cerebral infarction, patterns of BBB disruption and CBV varied at the contrast enhanced lesions according to the result of DCT. However, all contrast enhanced lesions with increased PH were associated with hemorrhagic infarction. Thus, the precise analysis of DCT provides appropriate therapeutic schedules by predicting the occurrence of hemorrhagic infarction. (author)

  10. Contrast-enhanced multislice pneumo-CT-cystography in the evaluation of urinary bladder neoplasms

    Energy Technology Data Exchange (ETDEWEB)

    Scardapane, Arnaldo [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy)], E-mail: scardapane@aruba.it; Pagliarulo, Vincenzo [Institute of Urology, University Hospital ' Policlinico' , Bari (Italy); Ianora, Amato A. Stabile [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy); Pagliarulo, Arcangelo [Institute of Urology, University Hospital ' Policlinico' , Bari (Italy); Angelelli, Giuseppe [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy)

    2008-05-15

    Purpose: To evaluate the accuracy of contrast-enhanced multislice CT (MSCT) in the study of urothelial tumors after distension of the bladder with air. Materials and methods: We evaluated 43 consecutive patients with endoscopically proven bladder lesions. After air distension of the bladder, unenhanced pelvic and enhanced abdomino-pelvic scans were obtained with the following protocol: thickness 2.5 mm x 4 mm, increment 1 mm, scan delay 40'' and 7-10 min. For each patient we considered the number, size, aspect (papillary or sessile) and contrast enhancement of lesions. Ureteral involvement and the presence of synchronous lesions in the excretory scan were also evaluated. MPR and virtual endoscopy images were reviewed in all cases. Results: Bladder lesions were visualized in 39/43 cases. Compared to conventional cystoscopy, MSCT recognized single lesions in 31/33 patients, two lesions in 4/6, three in 2/2 and more than five foci in 2/2 patients. A papillary aspect was described in 44 cases while 11 lesions were sessile. Conventional Cystoscopy recognized six more lesions as compared with MSCT (four flat and two small papillary lesions). The detection rate for protruding lesions was 100% (52/52) for lesions > 5 mm and 60% (3/5%) for lesions < 5 mm. In four patients hydronephrosis was present, while in one case a synchronous lesion was evident in the renal pelvis. Conclusion: Contrast-enhanced MSCT with air distension of the urinary bladder is a safe and complete investigation to evaluate the local stage of bladder cancer and to evaluate the ureteral extension of the tumor, as well as the presence of synchronous lesions.

  11. Comparison of FDG-PET/CT and contrast-enhanced CT for monitoring therapy response in patients with metastatic breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Riedl, Christopher C.; Ulaner, Gary A.; Jochelson, Maxine S.; Weber, Wolfgang A. [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Weill Cornell Medical College, Department of Radiology, New York, NY (United States); Pinker, Katja [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ong, Leonard T. [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Baltzer, Pascal [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); McArthur, Heather L. [Cedars-Sinai Medical Center, Department of Medicine, Breast Oncology, Los Angeles, CA (United States); Goenen, Mithat [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Dickler, Maura [Memorial Sloan Kettering Cancer Center, Department of Medicine, New York, NY (United States)

    2017-08-15

    The aim of this study was to compare fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) and contrast-enhanced computed tomography (CE-CT) for the prediction of progression-free survival (PFS) and disease-specific survival (DSS) in patients with stage IV breast cancer undergoing systemic therapy. Sixty-five patients with metastatic breast cancer treated with first- or second-line systemic therapy in prospective clinical trials were included. Response to treatment was evaluated by Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 for CE-CT and by PET Response Criteria in Solid Tumors (PERCIST), respectively. All responders by RECIST (n = 22) were also responders by PERCIST, but 40% (17/43) of non-responders by RECIST were responders by PERCIST. Responses according to RECIST and PERCIST both correlated with PFS, but PERCIST showed a significantly higher predictive accuracy (concordance index for PFS: 0.70 vs. 0.60). One-year PFS for responders vs. non-responders by RECIST was 59% vs. 27%, compared to 63% vs. 0% by PERCIST. Four-year DSS of responders and non-responders by RECIST was 50% and 38%, respectively (p = 0.2, concordance index: 0.55) as compared to 58% vs. 18% for PERCIST (p < 0.001, concordance index: 0.65). Response on PET/CT was also a significantly better predictor for DSS than disease control on CE-CT. In patients with metastatic breast cancer, tumor response on PET/CT appears to be a superior predictor of PFS and DSS than response on CE-CT. Monitoring tumor response by PET/CT may increase the power of clinical trials using tumor response as an endpoint, and may improve patient management in clinical routine. (orig.)

  12. The benefits of folic acid-modified gold nanoparticles in CT-based molecular imaging: radiation dose reduction and image contrast enhancement.

    Science.gov (United States)

    Beik, Jaber; Jafariyan, Maryam; Montazerabadi, Alireza; Ghadimi-Daresajini, Ali; Tarighi, Parastoo; Mahmoudabadi, Alireza; Ghaznavi, Habib; Shakeri-Zadeh, Ali

    2017-12-12

    X-ray computed tomography (CT) requires an optimal compromise between image quality and patient dose. While high image quality is an important requirement in CT, the radiation dose must be kept minimal to protect the patients from ionizing radiation-associated risks. The use of probes based on gold nanoparticles (AuNPs) along with active targeting ligands for specific recognition of cancer cells may be one of the balanced solutions. Herein, we report the effect of folic acid (FA)-modified AuNP as a targeted nanoprobe on the contrast enhancement of CT images as well as its potential for patient dose reduction. For this purpose, nasopharyngeal KB cancer cells overexpressing FA receptors were incubated with AuNPs with and without FA modification and imaged in a CT scanner with the following X-ray tube parameters: peak tube voltage of 130 KVp, and tube current-time products of 60, 90, 120, 160 and 250 mAs. Moreover, in order to estimate the radiation dose to which the patient was exposed during a head CT protocol, the CT dose index (CTDI) value was measured by an X-ray electrometer by changing the tube current-time product. Raising the tube current-time product from 60 to 250 mAs significantly increased the absorbed dose from 18 mGy to 75 mGy. This increase was not associated with a significant enhancement of the image quality of the KB cells. However, an obvious increase in image brightness and CT signal intensity (quantified by Hounsfield units [HU]) were observed in cells exposed to nanoparticles without any increase in the mAs product or radiation dose. Under the same Au concentration, KB cells exposed to FA-modified AuNPs had significantly higher HU and brighter CT images than those of the cells exposed to AuNPs without FA modification. In conclusion, FA-modified AuNP can be considered as a targeted CT nanoprobe with the potential for dose reduction by keeping the required mAs product as low as possible while enhancing image contrast.

  13. Virtual Non-Contrast CT Using Dual-Energy Spectral CT: Feasibility of Coronary Artery Calcium Scoring.

    Science.gov (United States)

    Song, Inyoung; Yi, Jeong Geun; Park, Jeong Hee; Kim, Sung Mok; Lee, Kyung Soo; Chung, Myung Jin

    2016-01-01

    To evaluate the feasibility of coronary artery calcium scoring based on three virtual noncontrast-enhanced (VNC) images derived from single-source spectral dual-energy CT (DECT) as compared with true noncontrast-enhanced (TNC) images. This prospective study was conducted with the approval of our Institutional Review Board. Ninety-seven patients underwent noncontrast CT followed by contrast-enhanced chest CT using single-source spectral DECT. Iodine eliminated VNC images were reconstructed using two kinds of 2-material decomposition algorithms (material density iodine-water pair [MDW], material density iodine-calcium pair [MDC]) and a material suppressed algorithm (material suppressed iodine [MSI]). Two readers independently quantified calcium on VNC and TNC images. The Spearman correlation coefficient test and Bland-Altman method were used for statistical analyses. Coronary artery calcium scores from all three VNC images showed excellent correlation with those from the TNC images (Spearman's correlation coefficient [ρ] = 0.94, 0.88, and 0.89 for MDW, MDC, and MSI, respectively; p VNC images also correlated well with those from TNC images (ρ = 0.92, 0.87, and 0.91 for MDW, MDC, and MSI, respectively; p VNC images, coronary calcium from MDW correlated best with that from TNC. The coronary artery calcium scores and volumes were significantly lower from the VNC images than from the TNC images (p VNC images from contrast-enhanced CT using dual-energy material decomposition/suppression is feasible for coronary calcium scoring. The absolute value from VNC tends to be smaller than that from TNC.

  14. Apparition of iodinated contrast agents in twin neonatal gastrointestinal tracts after maternal contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Kato, Hiroki; Kanematsu, Masayuki; Kato, Zenichiro; Kondo, Naomi; Orii, Kenji E.; Morimoto, Masahiro

    2011-01-01

    We describe a case of the appearance of iodinated contrast agents in the same locations of twins' neonatal gastrointestinal tracts 1 day after maternal contrast-enhanced computed tomography (CT). The CT examination had been performed on the expectant mother for suspected deep venous thrombosis on the day previous to the twin delivery. At 23 h after the CT examination and after cesarean section, iodinated contrast agents appeared in the same place in the twins' neonatal gastrointestinal tracts, mainly in the ascending colon, on plain abdominal radiographs. Radiologists, obstetricians, and pediatricians should understand the mechanism of appearance of iodinated contrast agents in fetal gastrointestinal tracts when the expectant mother had been given iodinated contrast agents intravenously shortly before delivery. (author)

  15. Virtual non-contrast computer tomography (CT) with spectral CT as an alternative to conventional unenhanced CT in the assessment of gastric cancer.

    Science.gov (United States)

    Tian, Shi-Feng; Liu, Ai-Lian; Wang, He-Qing; Liu, Jing-Hong; Sun, Mei-Yu; Liu, Yi-Jun

    2015-01-01

    The purpose of this study was to evaluate computed tomography (CT) virtual non-contrast (VNC) spectral imaging for gastric carcinoma. Fifty-two patients with histologically proven gastric carcinomas underwent gemstone spectral imaging (GSI) including non-contrast and contrast-enhanced hepatic arterial, portal venous, and equilibrium phase acquisitions prior to surgery. VNC arterial phase (VNCa), VNC venous phase (VNCv), and VNC equilibrium phase (VNCe) images were obtained by subtracting iodine from iodine/water images. Images were analyzed with respect to image quality, gastric carcinoma-intragastric water contrast-to-noise ratio (CNR), gastric carcinoma-perigastric fat CNR, serosal invasion, and enlarged lymph nodes around the lesions. Carcinoma-water CNR values were significantly higher in VNCa, VNCv, and VNCe images than in normal CT images (2.72, 2.60, 2.61, respectively, vs 2.35, p≤0.008). Carcinoma- perigastric fat CNR values were significantly lower in VNCa, VNCv, and VNCe images than in normal CT images (7.63, 7.49, 7.32, respectively, vs 8.48, pVNC arterial phase images may be a surrogate for conventional non-contrast CT images in gastric carcinoma evaluation.

  16. Predicting tumor hypoxia in non-small cell lung cancer by combining CT, FDG PET and dynamic contrast-enhanced CT.

    Science.gov (United States)

    Even, Aniek J G; Reymen, Bart; La Fontaine, Matthew D; Das, Marco; Jochems, Arthur; Mottaghy, Felix M; Belderbos, José S A; De Ruysscher, Dirk; Lambin, Philippe; van Elmpt, Wouter

    2017-11-01

    Most solid tumors contain inadequately oxygenated (i.e., hypoxic) regions, which tend to be more aggressive and treatment resistant. Hypoxia PET allows visualization of hypoxia and may enable treatment adaptation. However, hypoxia PET imaging is expensive, time-consuming and not widely available. We aimed to predict hypoxia levels in non-small cell lung cancer (NSCLC) using more easily available imaging modalities: FDG-PET/CT and dynamic contrast-enhanced CT (DCE-CT). For 34 NSCLC patients, included in two clinical trials, hypoxia HX4-PET/CT, planning FDG-PET/CT and DCE-CT scans were acquired before radiotherapy. Scans were non-rigidly registered to the planning CT. Tumor blood flow (BF) and blood volume (BV) were calculated by kinetic analysis of DCE-CT images. Within the gross tumor volume, independent clusters, i.e., supervoxels, were created based on FDG-PET/CT. For each supervoxel, tumor-to-background ratios (TBR) were calculated (median SUV/aorta SUV mean ) for HX4-PET/CT and supervoxel features (median, SD, entropy) for the other modalities. Two random forest models (cross-validated: 10 folds, five repeats) were trained to predict the hypoxia TBR; one based on CT, FDG, BF and BV, and one with only CT and FDG features. Patients were split in a training (trial NCT01024829) and independent test set (trial NCT01210378). For each patient, predicted, and observed hypoxic volumes (HV) (TBR > 1.2) were compared. Fifteen patients (3291 supervoxels) were used for training and 19 patients (1502 supervoxels) for testing. The model with all features (RMSE training: 0.19 ± 0.01, test: 0.27) outperformed the model with only CT and FDG-PET features (RMSE training: 0.20 ± 0.01, test: 0.29). All tumors of the test set were correctly classified as normoxic or hypoxic (HV > 1 cm 3 ) by the best performing model. We created a data-driven methodology to predict hypoxia levels and hypoxia spatial patterns using CT, FDG-PET and DCE-CT features in NSCLC. The

  17. Intravenous contrast injection significantly affects bone mineral density measured on CT

    NARCIS (Netherlands)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J. J.; Mohamed Hoesein, Firdaus A A; de Jong, Pim A.

    OBJECTIVE: The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. METHODS: One hundred and fifty-two patients (99 without and

  18. Correlation between image quality of CT scan and amount of intravenous contrast media

    International Nuclear Information System (INIS)

    Yoon, Dae Young; Choi, Dae Seob; Kim, Seung Hyup; Han, Joon Koo; Choi, Byung Ihn; Im, Jung Gi; Han, Moon Hee; Chang, Kee Hyun; Kim, Jong Hyo; Han, Man Chung

    1993-01-01

    A blind, comparative clinical study was performed prospectively to examine the correlation between image quality of CT scan in terms of contrast enhancement effect and amount of intravenous contrast media. A total of 357 patients were randomized into two groups. Ionic high-osmolality contrast media (68% meglumine ioglicate) was administered intravenously as 100 ml bolus in one group and as 50 ml bolus in the other group. Statistically significant differences of image quality were found in CT scans of the brain, head and neck, chest and abdomen (p 0.05). We suggest that amount of contrast media may be reduced in pelvis CT without significant degradation of image quality

  19. Indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced computed tomography: Assessment of the additional diagnostic value of contrast-enhanced ultrasound in the non-cirrhotic liver

    International Nuclear Information System (INIS)

    Quaia, Emilio; De Paoli, Luca; Angileri, Roberta; Cabibbo, Biagio; Cova, Maria Assunta

    2014-01-01

    Objective: To assess the additional diagnostic value of contrast-enhanced ultrasound (CEUS) in the characterization of indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced computed tomography (CT). Methods: Fifty-five solid hepatic lesions (1–4 cm in diameter) in 46 non-cirrhotic patients (26 female, 20 male; age ± SD, 55 ± 10 years) underwent CEUS after being detected on contrast-enhanced CT which was considered as non-diagnostic after on-site analysis. Two blinded independent readers assessed CT and CEUS scans and were asked to classify retrospectively each lesion as a malignant or benign based on reference diagnostic criteria for the different hepatic lesion histotypes. Diagnostic accuracy and confidence (area – A z – under ROC curve) were assessed by using gadobenate dimeglumine-enhanced magnetic resonance (MR) imaging (n = 30 lesions), histology (n = 7 lesions), or US follow-up (n = 18 lesions) as the reference standards. Results: Final diagnoses included 29 hemangiomas, 3 focal nodular hyperplasias, 1 hepatocellular adenoma, and 22 metastases. The additional review of CEUS after CT images improved significantly (P < .05) the diagnostic accuracy (before vs after CEUS review = 49% [20/55] vs 89% [49/55] – reader 1 and 43% [24/55] vs 92% [51/55] – reader 2) and confidence (A z , 95% Confidence Intervals before vs after CEUS review = .773 [.652–.895] vs .997 [.987–1] – reader 1 and .831 [.724–.938] vs .998 [.992–1] – reader 2). Conclusions: CEUS improved the characterization of indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced CT by identifying some specific contrast enhancement patterns.

  20. Solitary pulmonary nodules: Comparison of dynamic first-pass contrast-enhanced perfusion area-detector CT, dynamic first-pass contrast-enhanced MR imaging, and FDG PET/CT.

    Science.gov (United States)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Seki, Shinichiro; Tsubakimoto, Maho; Fujisawa, Yasuko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2015-02-01

    To prospectively compare the capabilities of dynamic perfusion area-detector computed tomography (CT), dynamic magnetic resonance (MR) imaging, and positron emission tomography (PET) combined with CT (PET/CT) with use of fluorine 18 fluorodeoxyglucose (FDG) for the diagnosis of solitary pulmonary nodules. The institutional review board approved this study, and written informed consent was obtained from each subject. A total of 198 consecutive patients with 218 nodules prospectively underwent dynamic perfusion area-detector CT, dynamic MR imaging, FDG PET/CT, and microbacterial and/or pathologic examinations. Nodules were classified into three groups: malignant nodules (n = 133) and benign nodules with low (n = 53) or high (n = 32) biologic activity. Total perfusion was determined with dual-input maximum slope models at area-detector CT, maximum and slope of enhancement ratio at MR imaging, and maximum standardized uptake value (SUVmax) at PET/CT. Next, all indexes for malignant and benign nodules were compared with the Tukey honest significant difference test. Then, receiver operating characteristic analysis was performed for each index. Finally, sensitivity, specificity, and accuracy were compared with the McNemar test. All indexes showed significant differences between malignant nodules and benign nodules with low biologic activity (P Dynamic perfusion area-detector CT is more specific and accurate than dynamic MR imaging and FDG PET/CT in the diagnosis of solitary pulmonary nodules in routine clinical practice. © RSNA, 2014.

  1. Impact of the use of contrast-enhancement multidetector CT for acute appendicitis: a prospective comparison with the Alvarado score

    International Nuclear Information System (INIS)

    Choi, Mi Young; Yoon, Seong Eon; Lee, Young Hwan; Choi, Shi Sung; Park, Seong Hoon; Juhng, Seong Kwan; Yoon, Kwon Ha; Park, Seong Ho

    2007-01-01

    To determine the diagnostic performance of contrast-enhanced multidetector CT (MDCT) and the Alvarado score for acute appendicitis. MDCT and determination of the Alvarado score were prospectively performed in 282 patients with 146 pathologically proven cases of acute appendicitis and 136 pathologically proven or clinically diagnosed cases of non-acute appendicitis. To compare the diagnostic performance of MDCT and the Alvarado score, the patients were subdivided according to age and sex, and receiver operating characteristics (ROC) analysis and Spearman rank correlation were performed. ROC analysis revealed that the optimal cut off value of the CT appendicitis grades was 2 in all patients, resulting in a sensitivity of 96.6% and a specificity of 94.9%. The optimal cut off values of the Alvarado score was different according to age and sex, resulting in a sensitivity of 85.6% and a specificity of 48.5%. There was a significant correlation between the CT appendicitis grades and the surgical-pathological grades (r = 0.496, ρ < .0001). However, no significant correlation was observed between the Alvarado score and the surgical-pathological grades. Contrast-enhanced MDCT has a higher diagnostic accuracy and significant correlation with pathological findings than those of the Alvarado score in patients with acute appendicitis

  2. Impact of the use of contrast-enhancement multidetector CT for acute appendicitis: a prospective comparison with the Alvarado score

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Mi Young; Yoon, Seong Eon; Lee, Young Hwan; Choi, Shi Sung; Park, Seong Hoon; Juhng, Seong Kwan; Yoon, Kwon Ha [Wonkwang University School of Medicine, Iksan (Korea, Republic of); Park, Seong Ho [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-12-15

    To determine the diagnostic performance of contrast-enhanced multidetector CT (MDCT) and the Alvarado score for acute appendicitis. MDCT and determination of the Alvarado score were prospectively performed in 282 patients with 146 pathologically proven cases of acute appendicitis and 136 pathologically proven or clinically diagnosed cases of non-acute appendicitis. To compare the diagnostic performance of MDCT and the Alvarado score, the patients were subdivided according to age and sex, and receiver operating characteristics (ROC) analysis and Spearman rank correlation were performed. ROC analysis revealed that the optimal cut off value of the CT appendicitis grades was 2 in all patients, resulting in a sensitivity of 96.6% and a specificity of 94.9%. The optimal cut off values of the Alvarado score was different according to age and sex, resulting in a sensitivity of 85.6% and a specificity of 48.5%. There was a significant correlation between the CT appendicitis grades and the surgical-pathological grades (r = 0.496, {rho} < .0001). However, no significant correlation was observed between the Alvarado score and the surgical-pathological grades. Contrast-enhanced MDCT has a higher diagnostic accuracy and significant correlation with pathological findings than those of the Alvarado score in patients with acute appendicitis.

  3. Weight-adapted iodinated contrast media administration in abdomino-pelvic CT: Can image quality be maintained?

    Science.gov (United States)

    Perrin, E; Jackson, M; Grant, R; Lloyd, C; Chinaka, F; Goh, V

    2018-02-01

    In many centres, a fixed method of contrast-media administration is used for CT regardless of patient body habitus. The aim of this trial was to assess contrast enhancement of the aorta, portal vein, liver and spleen during abdomino-pelvic CT imaging using a weight-adapted contrast media protocol compared to the current fixed dose method. Thirty-nine oncology patients, who had previously undergone CT abdomino-pelvic imaging at the institution using a fixed contrast media dose, were prospectively imaged using a weight-adapted contrast media dose (1.4 ml/kg). The two sets of images were assessed for contrast enhancement levels (HU) at locations in the liver, aorta, portal vein and spleen during portal-venous enhancement phase. The t-test was used to compare the difference in results using a non-inferiority margin of 10 HU. When the contrast dose was tailored to patient weight, contrast enhancement levels were shown to be non-inferior to the fixed dose method (liver p contrast dose reduction of 165 ml using the weight-adapted method compared to the fixed dose method, with a mean cost per patient of £6.81 and £7.19 respectively. Using a weight-adapted method of contrast media administration was shown to be non-inferior to a fixed dose method of contrast media administration. Patients weighing 76 kg, or less, received a lower contrast dose which may have associated cost savings. A weight-adapted contrast media protocol should be implemented for portal-venous phase abdomino-pelvic CT for oncology patients with adequate renal function (>70 ml/min/1.73 m 2 ). Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  4. Dual-energy MDCT: Comparison of pulmonary artery enhancement on dedicated CT pulmonary angiography, routine and low contrast volume studies

    Energy Technology Data Exchange (ETDEWEB)

    Godoy, Myrna C.B., E-mail: migbarco@gmail.com [New York University Langone Medical Center, Department of Radiology, New York, NY (United States); University of Texas M.D. Anderson Cancer Center, Department of Diagnostic Radiology, Houston, TX (United States); Heller, Samantha L.; Naidich, David P.; Assadourian, Bernard [New York University Langone Medical Center, Department of Radiology, New York, NY (United States); Leidecker, Christianne [Siemens Medical Solutions, Malvern, PA (United States); Schmidt, Bernhard [Siemens Healthcare, Forchheim (Germany); Vlahos, Ioannis [New York University Langone Medical Center, Department of Radiology, New York, NY (United States); St. George' s Hospital NHS Trust, London (United Kingdom)

    2011-08-15

    Purpose: The aim of this study was (a) to compare arterial enhancement in simultaneously acquired high- and low-kilovoltage images; and (b) to determine whether low tube-voltage imaging would permit PE evaluation on routine chest CT studies or CTPA studies performed with a low volume of contrast media. Materials and methods: We compared 20 CTPA studies (CTPA group), 20 routine thoracic CT studies (RT group) and 10 CTPA studies performed with reduced volume of contrast media (RC group). HU values were measured in all groups at 80 kVp and 140 kVp images in multiple pulmonary arterial segments bilaterally. The diagnostic quality of the central and peripheral vascular enhancement and the image noise were evaluated at both energies using a five-point scale. Results: For all patients, the mean CT attenuation values were greater at 80 kVp than 140 kVp images (p < 0.001). At 80 kVp, CTPA group attenuation values were greater than RT group (p = 0.03) with a similar trend at 140 kVp (p = 0.08). At both 140 kVp and 80 kVp, CTPA group attenuation values were greater than RC group (p = 0.02 and p = 0.03, respectively). Qualitative analysis showed that at 140 kVp CTPA studies had better global image quality scores than RT (p = 0.003) and RC (p = 0.001) groups. However, at 80 kVp, there was no significant difference of global image quality between CTPA and the other groups (p = 0.4 and p = 0.5, respectively). Although measurable image noise was greater at 80 kVp than 140 kVp (p < 0.001), qualitative analysis revealed lower image noise at 80 kVp images. Conclusion: DECT at 80 kVp increases arterial enhancement in both CTPA and routine studies. For routine studies this results in central and peripheral enhancement quality equivalent to that of CTPA studies. Low tube-voltage imaging allows marked contrast volume reduction for CTPA. In selected cases, satisfactory lower radiation dose CT might be achievable using lower kVp imaging alone.

  5. Assessing Tumor Response to Treatment in Patients with Lung Cancer Using Dynamic Contrast-Enhanced CT

    DEFF Research Database (Denmark)

    Strauch, Louise S; Eriksen, Rie Ø; Sandgaard, Michael

    2016-01-01

    Reviews and Meta-Analyses (PRISMA) guidelines. Only original research articles concerning treatment response in patients with lung cancer assessed with DCE-CT were included. To assess the validity of each study we implemented Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). The initial search......The aim of this study was to provide an overview of the literature available on dynamic contrast-enhanced computed tomography (DCE-CT) as a tool to evaluate treatment response in patients with lung cancer. This systematic review was compiled according to Preferred Reporting Items for Systematic...... yielded 651 publications, and 16 articles were included in this study. The articles were divided into groups of treatment. In studies where patients were treated with systemic chemotherapy with or without anti-angiogenic drugs, four out of the seven studies found a significant decrease in permeability...

  6. Highly sensitive detection of the soft tissues based on refraction contrast by in-plane diffraction-enhanced imaging CT

    International Nuclear Information System (INIS)

    Yuasa, Tetsuya; Hashimoto, Eiko; Maksimenko, Anton; Sugiyama, Hiroshi; Arai, Yoshinori; Shimao, Daisuke; Ichihara, Shu; Ando, Masami

    2008-01-01

    We discuss the recently proposed computed tomography (CT) technique based on refractive effects for biomedical use, which reconstructs the in-plane refractive-index gradient vector field in a cross-sectional plane of interest by detecting the angular deviation of the beam, refracted by a sample, from the incident beam, using the diffraction-enhanced imaging (DEI) method. The CT has advantages for delineating biological weakly absorbing soft tissues over the conventional absorption-contrast CT because of the use of phase sensitive detection. The paper aims to define the imaging scheme rigidly and to demonstrate its efficacy for non-destructive measurement of biomedical soft-tissue samples without imaging agent. We first describe the imaging principle of in-plane DEI-CT from the physico-mathematical viewpoints in detail, and investigate what physical quantities are extracted from the reconstructed images. Then, we introduce the imaging system using the synchrotron radiation as a light source, constructed at beamline BL-14B in KEK, Japan. Finally, we demonstrate the advantage of the refraction-based image for non-destructive analysis of biological sample by investigating the image of human breast cancer tumors obtained using the imaging system. Here, the refraction- and the apparent absorption-based images obtained simultaneously by the in-plane DEI-CT are compared. Also, the conventional absorption-based image obtained using micro-computed tomography (μCT) imaging system is compared with them. Thereby, it is shown that the refraction contrast much more sensitively delineates the soft tissues than the absorption contrast. In addition, the radiologic-histologic correlation study not only validates the efficacy for imaging soft tissues, but also produces the potential that the pathological inspection for the breast cancer tumors may be feasible non-destructively

  7. Characterization of tumor heterogeneity using dynamic contrast enhanced CT and FDG-PET in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Elmpt, Wouter van; Das, Marco; Hüllner, Martin; Sharifi, Hoda; Zegers, Catharina M.L.; Reymen, Bart; Lambin, Philippe; Wildberger, Joachim E.; Troost, Esther G.C.; Veit-Haibach, Patrick; De Ruysscher, Dirk

    2013-01-01

    Purpose: Dynamic contrast-enhanced CT (DCE-CT) quantifies vasculature properties of tumors, whereas static FDG-PET/CT defines metabolic activity. Both imaging modalities are capable of showing intra-tumor heterogeneity. We investigated differences in vasculature properties within primary non-small cell lung cancer (NSCLC) tumors measured by DCE-CT and metabolic activity from FDG-PET/CT. Methods: Thirty three NSCLC patients were analyzed prior to treatment. FDG-PET/CT and DCE-CT were co-registered. The tumor was delineated and metabolic activity was segmented on the FDG-PET/CT in two regions: low (<50% maximum SUV) and high (⩾50% maximum SUV) metabolic uptake. Blood flow, blood volume and permeability were calculated using a maximum slope, deconvolution algorithm and a Patlak model. Correlations were assessed between perfusion parameters for the regions of interest. Results: DCE-CT provided additional information on vasculature and tumor heterogeneity that was not correlated to metabolic tumor activity. There was no significant difference between low and high metabolic active regions for any of the DCE-CT parameters. Furthermore, only moderate correlations between maximum SUV and DCE-CT parameters were observed. Conclusions: No direct correlation was observed between FDG-uptake and parameters extracted from DCE-CT. DCE-CT may provide complementary information to the characterization of primary NSCLC tumors over FDG-PET/CT imaging

  8. Contrast enhanced ultrasound in liver imaging

    International Nuclear Information System (INIS)

    Nielsen, Michael Bachmann; Bang, Nanna

    2004-01-01

    Ultrasound contrast agents were originally introduced to enhance the Doppler signals when detecting vessels with low velocity flow or when imaging conditions were sub-optimal. Contrast agents showed additional properties, it was discovered that a parenchymal enhancement phase in the liver followed the enhancement of the blood pool. Contrast agents have made ultrasound scanning more accurate in detection and characterization of focal hepatic lesions and the sensitivity is now comparable with CT and MRI scanning. Further, analysis of the transit time of contrast agent through the liver seems to give information on possible hepatic involvement, not only from focal lesions but also from diffuse benign parenchymal disease. The first ultrasound contrast agents were easily destroyed by the energy from the sound waves but newer agents have proved to last for longer time and hereby enable real-time scanning and make contrast enhancement suitable for interventional procedures such as biopsies and tissue ablation. Also, in monitoring the effect of tumour treatment contrast agents have been useful. A brief overview is given on some possible applications and on different techniques using ultrasound contrast agents in liver imaging. At present, the use of an ultrasound contrast agent that allows real-time scanning with low mechanical index is to be preferred

  9. Bladder transitional cell carcinoma: correlation of contrast enhancement on computed tomography with histological grade and tumour angiogenesis

    International Nuclear Information System (INIS)

    Xie, Q.; Zhang, J.; Wu, P.-H.; Jiang, X.-Q.; Chen, S.-L.; Wang, Q.-L.; Xu, J.; Chen, G.-D.; Deng, J.-H.

    2005-01-01

    AIM: To investigate the correlation between the degree of contrast enhancement of bladder cancer in the early enhanced phase of helical computed tomography (CT) and microvessel density (MVD), vascular endothelial growth factor (VEGF) and histological grade. MATERIALS AND METHODS: Sixty-five patients with transitional cell carcinoma of the bladder were examined by incremental unenhanced CT and helical CT at 40-45 s after initiation of intravenous administration of contrast medium before surgery. The CT density in Hounsfield units of bladder carcinomas were measured in the middle of the maximum diameter section of the cancer lesions on unenhanced and enhanced CT. The degree of contrast enhancement of the tumour was determined as the absolute increase in Hounsfield units. Histological grade, VEGF and MVD were analysed for each cancer. The Pearson and Spearman correlation tests were used to determine the strength of the relationships between CT enhancement and histological grade, VEGF expression and MVD. RESULTS: Different degrees of enhancement were observed in 91 cancers during the early enhanced phase of helical CT. Mean MVDs and mean CT enhancing values of different histological grade groups were statistically different (p<0.001). A positive correlation was found in the CT-enhancing value of bladder cancer and MVD (Pearson correlation test; r=0.938, p<0.001) and histological grade (Spearman rank correlation; r=0.734, p<0.001). VEGF of bladder cancer did not correlate with the change in CT attenuation (Spearman rank correlation; r=0.087, p=0.410) and MVD (Spearman rank correlation, r=0.103, p=0.330). CONCLUSION: In bladder cancer, the degree of contrast enhancement during the early enhanced helical CT is correlated with the MVD and histological grade of tumour. It is possible that MVD is the histopathological basis of early contrast enhancement of bladder cancer

  10. Contrast enhancement of cerebral infarcts. Incidence and clinical value in different states of cerebral infarction

    International Nuclear Information System (INIS)

    Skriver, E.B.; Olsen, T.S.

    1982-01-01

    Information obtained from CT scan after contrast administration was evaluated in 59 consecutive stroke patients. CT scans before and after contrast administration were performed 3 days and 2 1/2 weeks after stroke. A plain CT scan was repeated 6 months later. Contrast enhancement was practically not seen on the first examination, but was seen in 46% on the second examination. There was a close relationship between the occurrence of contrast enhancement and the so called fogging effect. Contrast scanning gave additional information only when this effect was present. Plain CT scans 3 days after stroke were superior to contrast scans taken at any time for detecting and visualizing cerebral infarcts. (orig.)

  11. No increase in kidney injury molecule-1 and neutrophil gelatinase-associated lipocalin excretion following intravenous contrast enhanced-CT

    Energy Technology Data Exchange (ETDEWEB)

    Kooiman, Judith [Leiden University Medical Center, Department of Thrombosis and Haemostasis, Leiden (Netherlands); Leiden University Medical Center, Department of Nephrology, Leiden (Netherlands); Peppel, Wilke R. van de; Huisman, Menno V. [Leiden University Medical Center, Department of Thrombosis and Haemostasis, Leiden (Netherlands); Sijpkens, Yvo W.J. [Bronovo Hospital, Department of Nephrology, The Hague (Netherlands); Brulez, Harald F.H. [Sint Lucas Andreas Hospital, Department of Nephrology, Amsterdam (Netherlands); Vries, P.M. de [St. Antonius Hospital, Department of Vascular Surgery, Nieuwegein (Netherlands); Nicolaie, Mioara A.; Putter, H. [Leiden University Medical Center, Department of Medical Statistics and Bioinformatics, Leiden (Netherlands); Kooij, W. van der; Kooten, Cees van; Rabelink, Ton J. [Leiden University Medical Center, Department of Nephrology, Leiden (Netherlands)

    2015-07-15

    To analyze kidney injury molecule-1 (KIM-1) and neutrophil gelatinase-associated lipocalin (N-GAL) excretion post-intravenous contrast enhanced-CT (CE-CT) in patients with chronic kidney disease (CKD). Patients were enrolled in a trial on hydration regimes to prevent contrast-induced acute kidney injury (CI-AKI). Blood and urine samples were taken at baseline, 4 - 6, and 48 - 96 h post CE-CT. Urinary KIM-1 and N-GAL values were normalized for urinary creatinine levels, presented as medians with 2.5 - 97.5 percentiles. Of the enrolled 511 patients, 10 (2 %) were lost to follow-up. CI-AKI occurred in 3.9 % of patients (20/501). Median KIM-1 values were 1.2 (0.1 - 7.7) at baseline, 1.3 (0.1 - 8.6) at 4 - 6 h, and 1.3 ng/mg (0.1 - 8.1) at 48 - 96 h post CE-CT (P = 0.39). Median N-GAL values were 41.0 (4.4 - 3,174.4), 48.9 (5.7 - 3,406.1), and 37.8 μg/mg (3.5 - 3,200.4), respectively (P = 0.07). The amount of KIM-1 and N-GAL excretion in follow-up was similar for patients with and without CI-AKI (P-value KIM-1 0.08, P-value N-GAL 0.73). Neither patient characteristics at baseline including severe CKD, medication use, nor contrast dose were associated with increased excretion of KIM-1 or N-GAL during follow-up. KIM-1 and N-GAL excretion were unaffected by CE-CT both in patients with and without CI-AKI, suggesting that CI-AKI was not accompanied by tubular injury. (orig.)

  12. Contrast enhancement technique in brain 3D-CTA studies. Optimizing the amount of contrast medium according to scan time based on TDC

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi

    2008-01-01

    In three-dimensional CT angiography (3D-CTA), good reproducibility can be obtained by maintaining the maximum CT numbers (HU) at a specified level. However, the correlation between the scan time and the injection time showed that the maximum CT numbers increased and varied due to the additional contrast enhancement effect from recirculation of the injected contrast medium for longer injection times when the dose of iodinated contrast medium per unit time (mgI/s) was maintained at a specified level based on the time-density curve (TDC) of the phantom. The amount of contrast medium employed at our hospital has been optimized based on an iodinated contrast medium dose per unit time providing a contrast enhancement effect of 300 HU in the middle cerebral artery. Using this standard, a TDC phantom was employed to obtain an iodinated contrast medium dose per unit time, permitting equivalent maximum CT values (used as standard values) to be obtained by changing the injection time. A contrast-enhancement technique that accounts for the variation in the scan time was evaluated. Strong correlations were observed between the scan time and the injection time (R 2 =0.969) and between the injection time and the dose of iodinated contrast medium per unit body weight (R 2 =0.994). We conclude that adjusting the dose of iodinated contrast medium per unit body weight per unit time according to the scan time permits optimization of the contrast-enhancement technique. (author)

  13. Usefulness of contrast-enhanced transabdominal ultrasound for tumor classification and tumor staging in the pancreatic head

    DEFF Research Database (Denmark)

    Grossjohann, Hanne Sønder; Rappeport, Eli David; Jensen, Claus Verner

    2010-01-01

    To evaluate contrast-enhanced ultrasound (CEUS) and compare it to ultrasound (US) and 64-slice-CT (64-CT) for diagnosing, staging and evaluation of resectability of pancreatic cancer.......To evaluate contrast-enhanced ultrasound (CEUS) and compare it to ultrasound (US) and 64-slice-CT (64-CT) for diagnosing, staging and evaluation of resectability of pancreatic cancer....

  14. CT urography of urinary diversions with enhanced CT digital radiography: preliminary experience.

    Science.gov (United States)

    Sudakoff, Gary S; Guralnick, Michael; Langenstroer, Peter; Foley, W Dennis; Cihlar, Krista L; Shakespear, Jonathan S; See, William A

    2005-01-01

    The purpose of this study was to determine if 3D-rendered CT urography (CTU) depicts both normal and abnormal findings in patients with urinary diversions and if the addition of contrast-enhanced CT digital radiography (CTDR) improves opacification of the urinary collecting system. Thirty CTU and contrast-enhanced CTDR examinations were performed in 24 patients who underwent cystectomy for bladder cancer. Indications for evaluation included hematuria, tumor surveillance, or suspected diversion malfunction. All examinations were evaluated without knowledge of the stage or grade of a patient's tumor and were compared with the clinical records. Opacification of the urinary collecting system was evaluated with 3D CTU alone, contrast-enhanced CTDR alone, and combined CTU and CTDR. Nine abnormalities were identified including distal ureteral strictures (n = 4), vascular compression of the mid left ureter (n = 1), scarring of the mid right pole infundibulum (n = 1), bilateral hydronephrosis and hydroureter (n = 1), urinary reservoir calculus (n = 1), and tumor recurrence invading the afferent limb of the neobladder (n = 1). Eight of the nine detected abnormalities were surgically or pathologically confirmed. All abnormalities were identified on all three imaging techniques but were best seen on 3D CTU and enhanced CTDR images. Incomplete opacification of the urinary collecting system occurred in 17 patients with CTU alone, 12 patients with contrast-enhanced CTDR alone, and nine patients with combined CTU and contrast-enhanced CTDR. Compared with CTU alone, the combined technique of 3D CTU and contrast-enhanced CTDR improved opacification by a statistically significant difference (p = 0.037). CTU with 3D rendering can accurately depict both normal and abnormal postoperative findings in patients with urinary diversions. Adding enhanced CTDR can improve visualization of the urinary collecting system.

  15. Virtual non-contrast CT using dual energy spectral CT: Feasibility of coronary artery calcium scoring

    International Nuclear Information System (INIS)

    Song, In Young; Yi, Jeong Geun; Park, Jeong Hee; Lee, Sung Mok; Lee, Kyung Soo; Chung, Myung Jin

    2016-01-01

    To evaluate the feasibility of coronary artery calcium scoring based on three virtual noncontrast-enhanced (VNC) images derived from single-source spectral dual-energy CT (DECT) as compared with true noncontrast-enhanced (TNC) images. This prospective study was conducted with the approval of our Institutional Review Board. Ninety-seven patients underwent noncontrast CT followed by contrast-enhanced chest CT using single-source spectral DECT. Iodine eliminated VNC images were reconstructed using two kinds of 2-material decomposition algorithms (material density iodine-water pair [MDW], material density iodine-calcium pair [MDC]) and a material suppressed algorithm (material suppressed iodine [MSI]). Two readers independently quantified calcium on VNC and TNC images. The Spearman correlation coefficient test and Bland-Altman method were used for statistical analyses. Coronary artery calcium scores from all three VNC images showed excellent correlation with those from the TNC images (Spearman's correlation coefficient [ρ] = 0.94, 0.88, and 0.89 for MDW, MDC, and MSI, respectively; p < 0.001 for all pairs). Measured coronary calcium volumes from VNC images also correlated well with those from TNC images (ρ = 0.92, 0.87, and 0.91 for MDW, MDC, and MSI, respectively; p < 0.001 for all pairs). Among the three VNC images, coronary calcium from MDW correlated best with that from TNC. The coronary artery calcium scores and volumes were significantly lower from the VNC images than from the TNC images (p < 0.001 for all pairs). The use of VNC images from contrast-enhanced CT using dual-energy material decomposition/suppression is feasible for coronary calcium scoring. The absolute value from VNC tends to be smaller than that from TNC

  16. Virtual non-contrast CT using dual energy spectral CT: Feasibility of coronary artery calcium scoring

    Energy Technology Data Exchange (ETDEWEB)

    Song, In Young; Yi, Jeong Geun; Park, Jeong Hee [Dept. of Radiology, Konkuk University School of Medicine, Seoul (Korea, Republic of); Lee, Sung Mok; Lee, Kyung Soo; Chung, Myung Jin [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-06-15

    To evaluate the feasibility of coronary artery calcium scoring based on three virtual noncontrast-enhanced (VNC) images derived from single-source spectral dual-energy CT (DECT) as compared with true noncontrast-enhanced (TNC) images. This prospective study was conducted with the approval of our Institutional Review Board. Ninety-seven patients underwent noncontrast CT followed by contrast-enhanced chest CT using single-source spectral DECT. Iodine eliminated VNC images were reconstructed using two kinds of 2-material decomposition algorithms (material density iodine-water pair [MDW], material density iodine-calcium pair [MDC]) and a material suppressed algorithm (material suppressed iodine [MSI]). Two readers independently quantified calcium on VNC and TNC images. The Spearman correlation coefficient test and Bland-Altman method were used for statistical analyses. Coronary artery calcium scores from all three VNC images showed excellent correlation with those from the TNC images (Spearman's correlation coefficient [ρ] = 0.94, 0.88, and 0.89 for MDW, MDC, and MSI, respectively; p < 0.001 for all pairs). Measured coronary calcium volumes from VNC images also correlated well with those from TNC images (ρ = 0.92, 0.87, and 0.91 for MDW, MDC, and MSI, respectively; p < 0.001 for all pairs). Among the three VNC images, coronary calcium from MDW correlated best with that from TNC. The coronary artery calcium scores and volumes were significantly lower from the VNC images than from the TNC images (p < 0.001 for all pairs). The use of VNC images from contrast-enhanced CT using dual-energy material decomposition/suppression is feasible for coronary calcium scoring. The absolute value from VNC tends to be smaller than that from TNC.

  17. Contrast-Enhanced Proton Radiography for Patient Set-up by Using X-Ray CT Prior Knowledge

    Energy Technology Data Exchange (ETDEWEB)

    Spadea, Maria Francesca, E-mail: mfspadea@unicz.it [Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro (Italy); Fassi, Aurora [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano (Italy); Zaffino, Paolo [Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro (Italy); Riboldi, Marco; Baroni, Guido [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano (Italy); Bioengineering Unit—CNAO Foundation, Pavia (Italy); Depauw, Nicolas [Department of Radiation Oncology, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts (United States); Centre for Medical Radiation Physics, University of Wollongong, Wollongong (Australia); Seco, Joao [Department of Radiation Oncology, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts (United States)

    2014-11-01

    Purpose: To obtain a contrasted image of the tumor region during the setup for proton therapy in lung patients, by using proton radiography and x-ray computed tomography (CT) prior knowledge. Methods and Materials: Six lung cancer patients' CT scans were preprocessed by masking out the gross tumor volume (GTV), and digitally reconstructed radiographs along the planned beam's eye view (BEV) were generated, for a total of 27 projections. Proton radiographies (PR) were also computed for the same BEV through Monte Carlo simulations. The digitally reconstructed radiograph was subtracted from the corresponding proton image, resulting in a contrast-enhanced proton radiography (CEPR). Michelson contrast analysis was performed both on PR and CEPR. The tumor region was then automatically segmented on CEPR and compared to the ground truth (GT) provided by physicians in terms of Dice coefficient, accuracy, precision, sensitivity, and specificity. Results: Contrast on CEPR was, on average, 4 times better than on PR. For 10 lateral projections (±45° off of 90° or 270°), although it was not possible to distinguish the tumor region in the PR, CEPR offers excellent GTV visibility. The median ± quartile values of Dice, precision, and accuracy indexes were 0.86 ± 0.03, 0.86 ± 0.06, and 0.88 ± 0.02, respectively, thus confirming the reliability of the method in highlighting tumor boundaries. Sensitivity and specificity analysis demonstrated that there is no systematic over- or underestimation of the tumor region. Identification of the tumor boundaries using CEPR resulted in a more accurate and precise definition of GTV compared to that obtained from pretreatment CT. Conclusions: In most proton centers, the current clinical protocol is to align the patient using kV imaging with bony anatomy as a reference. We demonstrated that CEPR can significantly improve tumor visualization, allowing better patient set-up and permitting image guided proton therapy (IGPT)

  18. Diagnostic performance of contrast enhanced CT and 18F-FDG PET/CT in suspicious recurrence of biliary tract cancer after curative resection

    International Nuclear Information System (INIS)

    Lee, Yun-Gyoo; Bang, Yung-Jue; Han, Sae-Won; Oh, Do-Youn; Chie, Eui Kyu; Jang, Jin-Young; Im, Seock-Ah; Kim, Tae-You; Kim, Sun-Whe; Ha, Sung Whan

    2011-01-01

    Because of the late clinical presentation of biliary tract cancer (BTC), only 10% of patients are eligible for curative surgery. Even among those patients who have undergone curative surgery, most patients develop recurrent cancer. This study is to determine the clinical role of 18 F-FDG PET/CT during post-operative surveillance of suspected recurrent BTC based on symptoms, laboratory findings and contrast-enhanced CT (ceCT) findings. We consecutively enrolled 50 patients with BTC who underwent curative surgery. An 18 F-FDG PET/CT was obtained for assessment of recurrence based on clinical suspicion during post-operative surveillance. The final confirmation of recurrence was determined pathologically or clinically. When a pathologic confirmation was impossible or inconclusive, a clinical confirmation was used by radiologic correlation with subsequent follow-up ceCT at a minimum of 3-month intervals. Diagnostic efficacy was evaluated by comparing the results of ceCT and 18 F-FDG PET/CT with the final diagnosis. Among the 50 patients, 34(68%) were confirmed to have a recurrence. PET/CT showed higher sensitivity (88% vs. 76%, p = 0.16) and accuracy (82% vs. 66%, p = 0.11) for recurrence compared to ceCT, even though the difference was not significant. The positive (86% vs. 74%, p = 0.72) and negative predictive values for recurrence (73% vs. 47%, p = 0.55) were not significantly different between PET/CT and ceCT. However, an additional PET/CT on ceCT significantly improved the sensitivity than did a ceCT alone (94% [32/34] for PET/CT on ceCT vs. 76% [26/34] for ceCT alone, p = 0.03) without increasing the specificity, positive predictive value, and negative predictive value. 18 F-FDG PET/CT alone is not more sensitive or specific than ceCT in the detection of recurrent BTC after curative surgery. These results do not reach statistical significance, probably due to the low number of patients. However, an additional 18 F-FDG PET/CT on ceCT significantly improves the

  19. Therapeutic response assessment of percutaneous radiofrequency ablation for hepatocellular carcinoma: Utility of contrast-enhanced agent detection imaging

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Choi, Dongil; Lim, Hyo K.; Kim, Seung Hoon; Lee, Won Jae; Kim, Min Ju; Lee, Ji Yeon; Jeon, Yong Hwan; Lee, Jongmee; Lee, Soon Jin; Lim, Jae Hoon

    2005-01-01

    Purpose: To assess the utility of contrast-enhanced agent detection imaging (ADI) in the assessment of the therapeutic response to percutaneous radiofrequency (RF) ablation in patients with hepatocellular carcinoma (HCC). Materials and methods: Ninety patients with a total of 97 nodular HCCs (mean, 2.1 ± 1.3 cm; range, 1.0-5.0 cm) treated with percutaneous RF ablation under the ultrasound guidance were evaluated with contrast-enhanced ADI after receiving an intravenous bolus injection of a microbubble contrast agent (SH U 508A). We obtained serial contrast-enhanced ADI images during the time period from 15 to 90 s after the initiation of the bolus contrast injection. All of the patients underwent a follow-up four-phase helical CT at 1 month after RF ablation, which was then repeated at 2-4 month intervals during a period of at least 12 months. The results of the contrast-enhanced ADI were compared with those of the follow-up CT in terms of the presence or absence of residual unablated tumor and local tumor progression in the treated lesions. Results: On contrast-enhanced ADI, technical success was obtained in 94 (97%) of the 97 HCCs, while residual unablated tumors were found in three HCCs (3%). Two of the three tumors that were suspicious (was not proven) for incomplete ablation were subjected to additional RF ablation. The remaining one enhancing lesion that was suspicious of a residual tumor on contrast-enhanced ADI was revealed to be reactive hyperemia at the 1-month follow-up CT. Therefore; the diagnostic concordance between the contrast-enhanced ADI and 1-month follow-up CT was 99%. Of the 94 ablated HCCs without residual tumors on both the contrast-enhanced ADI and 1-month follow-up CT after the initial RF ablation, five (5%) had CT findings of local tumor progression at a subsequent follow-up CT. Conclusion: Despite its limitations in predicting local tumor progression in the treated tumors, contrast-enhanced ADI is potentially useful for evaluating the

  20. Multimodality functional imaging of spontaneous canine tumors using 64Cu-ATSM and 18FDG PET/CT and dynamic contrast enhanced perfusion CT

    International Nuclear Information System (INIS)

    Hansen, Anders E.; Kristensen, Annemarie T.; Law, Ian; McEvoy, Fintan J.; Kjær, Andreas; Engelholm, Svend A.

    2012-01-01

    Purpose: To compare the distribution and uptake of the hypoxia tracer 64 Cu-diacetyl-bis(N 4 -methylthiosemicarbazone) ( 64 Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition 64 Cu-ATSM distribution over time was evaluated. Methods and materials: Nine spontaneous cancer-bearing dogs were prospectively enrolled. FDG (1 h pi.) and 64 Cu-ATSM (3 and 24 h pi.) PET/CT were performed over three consecutive days. DCE-pCT was performed on day 2. Tumor uptake of FDG and 64 Cu-ATSM was assessed semi-quantitatively and the distribution of FDG, 64 Cu-ATSM and CT perfusion parameters correlated. Results: 64 Cu-ATSM distribution on scans performed 24 h apart displayed moderate to strong correlation; however, temporal changes were observed. The spatial distribution pattern of 64 Cu-ATSM between scans was moderately to strongly positively correlated to FDG, whereas the correlation of CT perfusion parameters to FDG and to 64 Cu-ATSM yielded more varying results. Conclusions: 64 Cu-ATSM uptake was positively correlated to FDG. 64 Cu-ATSM was found to be relatively stable between PET scans performed at different time points, important temporal changes were however observed in hypo-perfused regions. These findings potentially indicate that prolonged uptake periods for 64 Cu-ATSM imaging may be needed. Although a moderate to strong correlation between 64 Cu-ATSM and FDG PET/CT is observed, the two tracers provide different biological information with an overlapping spatial distribution.

  1. Automated Detection of Healthy and Diseased Aortae from Images Obtained by Contrast-Enhanced CT Scan

    Directory of Open Access Journals (Sweden)

    Michael Gayhart

    2013-01-01

    Full Text Available Purpose. We developed the next stage of our computer assisted diagnosis (CAD system to aid radiologists in evaluating CT images for aortic disease by removing innocuous images and highlighting signs of aortic disease. Materials and Methods. Segmented data of patient’s contrast-enhanced CT scan was analyzed for aortic dissection and penetrating aortic ulcer (PAU. Aortic dissection was detected by checking for an abnormal shape of the aorta using edge oriented methods. PAU was recognized through abnormally high intensities with interest point operators. Results. The aortic dissection detection process had a sensitivity of 0.8218 and a specificity of 0.9907. The PAU detection process scored a sensitivity of 0.7587 and a specificity of 0.9700. Conclusion. The aortic dissection detection process and the PAU detection process were successful in removing innocuous images, but additional methods are necessary for improving recognition of images with aortic disease.

  2. Investigating the use of texture features for analysis of breast lesions on contrast-enhanced cone beam CT

    Science.gov (United States)

    Wang, Xixi; Nagarajan, Mahesh B.; Conover, David; Ning, Ruola; O'Connell, Avice; Wismueller, Axel

    2014-04-01

    Cone beam computed tomography (CBCT) has found use in mammography for imaging the entire breast with sufficient spatial resolution at a radiation dose within the range of that of conventional mammography. Recently, enhancement of lesion tissue through the use of contrast agents has been proposed for cone beam CT. This study investigates whether the use of such contrast agents improves the ability of texture features to differentiate lesion texture from healthy tissue on CBCT in an automated manner. For this purpose, 9 lesions were annotated by an experienced radiologist on both regular and contrast-enhanced CBCT images using two-dimensional (2D) square ROIs. These lesions were then segmented, and each pixel within the lesion ROI was assigned a label - lesion or non-lesion, based on the segmentation mask. On both sets of CBCT images, four three-dimensional (3D) Minkowski Functionals were used to characterize the local topology at each pixel. The resulting feature vectors were then used in a machine learning task involving support vector regression with a linear kernel (SVRlin) to classify each pixel as belonging to the lesion or non-lesion region of the ROI. Classification performance was assessed using the area under the receiver-operating characteristic (ROC) curve (AUC). Minkowski Functionals derived from contrastenhanced CBCT images were found to exhibit significantly better performance at distinguishing between lesion and non-lesion areas within the ROI when compared to those extracted from CBCT images without contrast enhancement (p < 0.05). Thus, contrast enhancement in CBCT can improve the ability of texture features to distinguish lesions from surrounding healthy tissue.

  3. The influence of different contrast medium concentrations and injection protocols on quantitative and clinical assessment of FDG–PET/CT in lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Verburg, Frederik A., E-mail: fverburg@ukaachen.de [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Kuhl, Christiane K. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Pietsch, Hubertus [Bayer Pharma AG, Berlin, Müllerstrasse 178, 13353 Berlin (Germany); Palmowski, Moritz [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Mottaghy, Felix M. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Behrendt, Florian F. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany)

    2013-10-01

    Objectives: To compare the effects of two different contrast medium concentrations for use in computed X-ray tomography (CT) employing two different injection protocols on positron emission tomography (PET) reconstruction in combined 2-{sup 18}F-desoxyglucose (FDG) PET/CT in patients with a suspicion of lung cancer. Methods: 120 patients with a suspicion of lung cancer were enrolled prospectively. PET images were reconstructed with the non-enhanced and venous phase contrast CT obtained after injection of iopromide 300 mg/ml or 370 mg/ml using either a fixed-dose or a body surface area adapted injection protocol. Maximum and mean standardized uptake values (SUVmax and SUVmean) and contrast enhancement (HU) were determined in the subclavian vein, ascending aorta, abdominal aorta, inferior vena cava, portal vein, liver and kidney and in the suspicious lung lesion. PET data were evaluated visually for the presence of malignancy and image quality. Results: At none of the sites a significant difference in the extent of the contrast enhancement between the four different protocols was found. However, the variability of the contrast enhancement at several anatomical sites was significantly greater in the fixed dose groups than in the BSA groups for both contrast medium concentrations. At none of the sites a significant difference was found in the extent of the SUVmax and SUVmean increase as a result of the use of the venous phase contrast enhanced CT for attenuation. Visual clinical evaluation of lesions showed no differences between contrast and non-contrast PET/CT (P = 0.32). Conclusions: Contrast enhanced CT for attenuation correction in combined PET/CT in lung cancer affects neither the clinical assessment nor image quality of the PET-images. A body surface adapted contrast medium protocol reduces the interpatient variability in contrast enhancement.

  4. Gastric stromal tumor: two-phase dynamic CT findings with water as oral contrast agents

    International Nuclear Information System (INIS)

    Lee, Se Hyo; Cho, June Sik; Shin, Kyung Sook; Jeong, Ki Ho; Park, Jin Yong; Yu, Ho Jun; Kim, Young Min; Jeon, Kwang Jin

    2000-01-01

    To evaluate two-phase dynamic CT with water as oral contrast agents in the CT diagnosis of gastric stromal tumors. We retrospectively reviewed the CT findings in 21 patients with pathologically proven gastric stromal tumors. Six were found to be benign, twelve were malignant, and there were three cases of STUMP (stromal tumor uncertain malignant potential). Two-phase dynamic CT scans with water as oral contrast agents were obtained 60-70 secs (portal phase) and 3 mins (equilibrium phase) after the start of IV contrast administration. We determined the size, growth pattern, and enhancement pattern of the tumors and overlying mucosa, the presence or absence of ulceration and necrosis, tumor extent, and lymph nod and distant metastasis. The CT and pathologic findings were correlated. All six benign tumors and three STUMP were less than 5.5 cm in size, and during the portal phase showed round endogastric masses with highly enhanced, intact overlying mucosa. Twelve malignant tumors were 4.5-15.5 cm in size (mean, 11.5 cm); an endogastric mass was seen in three cases, an exogastric mass in one, and a mixed pattern in eight. On portal phase images the tumors were not significantly enhanced, but highly enhanced feeding vessels were noted in five larger tumors (greater than 10 cm). All 12 malignant tumors showed ulceration and necrosis, and interruption of overlying mucosa was clearly seen during the portal phase. We were readily able to evaluate tumor extent during this phase, and in ten malignant tumors there was no invasion of adjacent organs. Seven malignant tumors showed air density within their necrotic portion (p less than 0.05). On equilibrium phase images, all malignant tumors showed heterogeneous enhancement due to necrosis, and poorly enhanced overlying mucosa. Dynamic CT during the portal phase with water as oral contrast agents was useful for depicting the submucosal origin of gastric stromal tumors and for evaluating the extent of malignant stromal tumors. Our

  5. Analysis of peritumoral edema and contrast enhancement by computerized axial tomography

    International Nuclear Information System (INIS)

    Oi, Shizuo; Szper, I.; Wetzel, N.; Kim, Kwang-S.

    1980-01-01

    For the purpose of treating brain tumors satisfactorily with steroids, CT findings of brain tumors were analyzed, and pathogenesis of peritumoral edema and supposed effects of steroids were investigated. The degree of peritumoral edema and contrast enhancement and their relationship were analyzed in total 201 patients with brain tumors (gliomas, meningiomas, and metastatic brain tumors). As a result, significant peritumoral edema was recognized in 59% of patients with metastatic brain tumors, 46% of patients with glioma, and 34% of patients with meningioma. As a rule, there was a relationship between peritumoral edema and malignancy or localization of braiin tumors. Severe peritumoral edema was observed in malignant supratentorial tumors (over 60%), but peritumoral edema which was found in infratentorial tumors benign gliomas was mild. The degree of contrast enhancement differed according to tumors, and there was not always a relationship between the degree of contrast enhancement and malignancy or localization of brain tumors. CT findings of brain tumors after the administration of steroids showed decrease in the degree of contrast enhancement. Judging from the effect of steroids to inhibit increased vascular permeability associated with brain edema, like CT findings of peritumoral edema, the degree of contrast enhancement which probably expressed vascularity or vascular permeability seemed to be important in deciding the indications for steroid administration. (Tsunoda, M.)

  6. Dynamic contrast enhanced CT measurement of blood flow during interstitial laser photocoagulation: comparison with an Arrhenius damage model

    International Nuclear Information System (INIS)

    Purdie, T.J.; Lee, T.J.; Iizuka, M.; Sherar, M.D.

    2000-01-01

    One effect of heating during interstitial laser photocoagulation (ILP) is to directly destroy the tumour vasculature resulting in a loss of viable blood supply. Therefore, blood flow measured during and after treatment can be a useful indicator of tissue thermal damage. In this study, the effect of ILP treatment on rabbit thigh tumours was investigated by measuring blood flow changes using dynamic contrast enhanced computed tomography (CT). The CT measured changes in blood flow of treated tumour tissue were fitted to an Arrhenius model assuming first order rate kinetics. Our results show that changes in blood flow of tumour tissue distant from surrounding normal tissue are well described by an Arrhenius model. By contrast, the temperature profile of tumour tissue adjacent to normal tissue must be modified to account for heat dissipation by the latter. Finally, the Arrhenius parameters derived in the study are similar to those derived by heating tumour tissue to a lower temperature (<47 deg. C) than the current study. In conclusion, CT can be used to monitor blood flow changes during ILP and these measurements are related to the thermal damage predicted by the Arrhenius model. (author)

  7. Streak artifacts on Kidney CT: Ionic vs nonionic contrast media

    International Nuclear Information System (INIS)

    Cho, Eun Ok; Kim, Won Hong; Jung, Myung Suk; Kim, Yong Hoon; Hur, Gham

    1993-01-01

    The authors reviewed findings of enhanced abdominal computed tomography (CT) scans to know the difference between a higher dose of conventional ionic contrast media(iothalamate meglumine) and a lower dose of a new, nonionic contrast material(ioversol). One hundred adult patients were divided into two groups. Each group consisted of 50 patients. Iothalamate meglumine and ioversol were intravenously administered in each group. The radio of the male to female in the former was 28:22, and the latter 29:21. We examine the degree of renal streak artifact and measure the Hounsfield number of urine in renal collecting system. There were significant differences of the degree of the streak artifact depending upon the osmolality of contrast media used and that was related with urine CT number(P value<0.005). We authors conclude that nonionic low osmolar contrast media is prone to cause streak artifacts and distortions of renal image than conventional ionic high osmolar contrast media

  8. Synthesis of PEG-Iodine-Capped Gold Nanoparticles and Their Contrast Enhancement in In Vitro and In Vivo for X-Ray/CT

    International Nuclear Information System (INIS)

    Sun-Hee, K.; Eun-Mi, K.; Chang-Moon, L.; Dong, W.K.; Seok, T.L.; Myung-Hee, S.; Hwan-Jeong, J.

    2012-01-01

    We designed gold nanoparticles (AuNPs) capped with iodine and polyethylene glycol (PEG) to provide effective enhancement for X-ray CT imaging. The methoxy PEG-iodine-capped AuNPs were prepared through the chemisorption of iodine and substitution of methoxy PEG-SH onto the surface of gold nanoparticles, and severe aggregation in TEM was not observed. The binding energies of Au 4f 7/2 and I 3d 5/2 of the methoxy PEG-iodine-capped AuNPs were obtained as 84.1 eV and 619.3 eV, respectively. The binding energy shift of methoxy PEG-iodine-capped AuNPs would be resulted from the chemisorption between gold nanoparticles and iodine atoms. The methoxy PEG-iodine-capped AuNPs have higher enhancement compared to PEG-capped gold nanoparticles in the same amount of gold in vitro. After postinjection of methoxy PEG-iodine-capped AuNPs into the mice, dramatic contrast enhancement at the heart, aorta, liver, and kidney was observed, this was maintained up to 5 days, and there was no evidence of apparent toxicity. In conclusion, methoxy PEG-iodine-capped AuNPs might be a good candidate as a CT contrast agent for blood pool imaging, and this will also contribute to the prolongation of a blood circulation time for X-ray CT imaging.

  9. 18F-FDG PET/contrast enhanced CT in the standard follow-up of patients with lymphoma.

    Science.gov (United States)

    García Vicente, A M; Talavera Rubio, M P; Dominguez Ferreras, E; Calle Primo, C; Amo-Salas, M; Tello Galán, M J; Jiménez Londoño, G A; Jiménez Aragón, F; Hernández Ruiz, B; Soriano Castrejón, Á

    To assess the diagnostic accuracy of 18 F-FDG PET/contrast enhanced computed tomography (ceCT) in the detection of asymptomatic recurrences in patients with lymphoma. Patients with lymphoma and clinical complete remission underwent 18 F-FDG PET/ceCT for standard follow-up. 18 F-FDG PET and ceCT were evaluated blindly by two independent observers, and classified as positive or negative for recurrence. Additionally a combined evaluation of both techniques was performed. The final diagnosis was established by histopathological analysis or a clinical follow-up longer than 6 months. Statistical diagnostic parameters and concordance levels between both diagnostic techniques were calculated. A total of 114 explorations on 90 patients were analyzed. Only 4 patients were diagnosed as asymptomatic recurrence during the follow-up. 18 F-FDG PET/ceCT, 18 F-FDG PET and ceCT showed an association with the final diagnosis (p=0.002 and χ 2 =11.96; p<0.001 and χ 2 =15.60; p=0.001 and χ 2 =11.96, respectively). The concordance between 18 F-FDG PET and ceCT was moderate/high and significant (kappa=0.672; p<0.001). A sensitivity and specificity of 50% and 88% was obtained for the 18 F-FDG PET/ceCT civ, 50% and 93% for the 18 F-FDG PET, and 50% and 91% for the ceCT. The combined use of 18 F-FDG PET/ceCT did not offer any advantage compared to any isolated diagnostic technique in the detection of asymptomatic lymphoma recurrence. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  10. Clinical courses and CT findings in the patients with contrast media-associated seizures

    International Nuclear Information System (INIS)

    Onda, Kiyoshi; Takeda, Norio; Tanaka, Ryuichi

    1987-01-01

    From February 1976 through March 1985, 12,479 patients underwent cranial computed tomography (CT) examinations with 65 % Angiografin (100 ml/kg for adults and 2 ml/kg for children). Among them, five patients experienced contrast media-associated seizures. The present study analyzed (1) the time of occurrence of seizures, (2) CT appearances at the time of seizures, (3) epileptogenecity, and (4) clinical features of seizures. Two patients had malignant gliomas, 2 metastatic brain tumors, and one hemangioendothelioma. Seizures occurred at CT examinations performed after the initial treatment, such as radiation or surgery, with the incidence for each patient varing from 2 to 5. There were lesions near the motor cortex on CT scans, and enhancement was observed in most cases. Three patients had experienced epilepsy attacks due to their underlying diseases. In the other two, contrast media-associated seizures preceded the occasional onset of epilepsy attacks. This strongly suggested the influence of their underlying diseases in the occurrence of contrast media-associated seizures. A careful use of contrast media for cranial CT examination is emphasized. (Namekawa, K.)

  11. Neuro-Behcet's syndrome with contrast enhancement on brain computed tomography

    International Nuclear Information System (INIS)

    Yamada, Takeshi; Tobimatsu, Shozo; Itoyama, Yasuto; Goto, Ikuo; Kuroiwa, Yoshigoro

    1986-01-01

    Two cases of neuro-Behcet's syndrome (N-B) with contrast enhancement (enhancement) on brain computed tomography (CT) are reported. Case 1. A 34-year-old man, who had a history of recurrent aphthous stomatitis, developed a left inferior homonymous quadrantanopsia. CT scans showed a large lucent area with a ring-like enhancement (3 cm in diameter) lesion in the right parietooccipital region. When he developed a left hemiplegia, CT scans showed a irregular lucent area with heterogenous enhancement lesions in the right basal ganglia and midbrain. Case 2. A 38-year-old woman, who had a history of recurrent aphthous stomatitis and genital ulcer, developed mental confusion. CT scans showed a large lucent area with a homogenous marked round enhancement lesion in the left basal ganglia. When she developed generalized convulsion, CT scans showed a large lucent area with a heterogenous irregular enhancement lesion in the right occipital lobe. Enhancement lesions were observed in the area corresponded to their neurological symptoms during acute exacerbations and disappeared within three months. Our cases suggest that N-B with acute exacerbations could show transient enhancement on CT. (author)

  12. Advanced imaging of the musculoskeletal system: Standard, three-dimensional, and contrast-enhanced CT and MR imaging, and quantitative bone densitometry

    International Nuclear Information System (INIS)

    Resnick, D.; Sartoris, D.J.

    1987-01-01

    This course reviews the application of advanced imaging techniques to a broad spectrum of musculoskeletal disorders. The indications for and utility of standard CT in both the axial and the appendicular skeleton is explored. The combined use of CT with air and contrast arthrography at sites including the hip, knee, and shoulder is discussed. A summary of the proved and potential applications of MR imaging in osseous, articular, bone marrow, and soft-tissue disorders is provided. The utility of intraarticular contrast agents in enhancing the diagnostic capabilities of MR imaging for disorders of hyaline cartilage and and fibrocartilage is demonstrated. The advantages of multiplanar reformation and three-dimensional image reconstruction of cross-sectional imaging data are described in conjunction with the fundamental technological principles of these strategies. Accepted methods as well as investigative techniques for the diagnosis and follow-up of metabolic bone disease are contrasted with regard to relative indications, advantages, and limitations

  13. 18F-Fluorodeoxyglucose PET/CT and dynamic contrast-enhanced MRI as imaging biomarkers in malignant pleural mesothelioma.

    Science.gov (United States)

    Hall, David O; Hooper, Clare E; Searle, Julie; Darby, Michael; White, Paul; Harvey, John E; Braybrooke, Jeremy P; Maskell, Nick A; Masani, Vidan; Lyburn, Iain D

    2018-02-01

    The purpose of this study was to compare the use of fluorine-18-fluorodeoxyglucose (F-FDG) PET with computed tomography (CT) and dynamic contrast-enhanced (DCE) MRI to predict prognosis and monitor treatment in malignant pleural mesothelioma. F-FDG PET/CT and DCE-MRI studies carried out as part of the South West Area Mesothelioma Pemetrexed trial were used. F-FDG PET/CT and DCE-MRI studies were carried out before treatment, and after two cycles of chemotherapy, on patients treated with pemetrexed and cisplatin. A total of 73 patients were recruited, of whom 65 had PET/CT and DCE-MRI scans. Baseline measurements from F-FDG PET/CT (maximum standardized uptake value, metabolic tumour volume and total lesion glycolysis) and DCE-MRI (integrated area under the first 90s of the curve and washout slope) were compared with overall survival (OS) using Kaplan-Meier and Cox regression analyses, and changes in imaging measurements were compared with disease progression. PET/CT and DCE-MRI measurements were not correlated with each other. Maximum standardized uptake value, metabolic tumour volume and total lesion glycolysis were significantly related to OS with Cox regression analysis and Kaplan-Meir analysis, and DCE-MRI washout curve shape was significantly related to OS. DCE-MRI curve shape can be combined with F-FDG PET/CT to give additional prognostic information. Changes in measurements were not related to progression-free survival. F-FDG PET/CT and DCE-MRI give prognostic information in malignant pleural mesothelioma. Neither PET/CT nor DCE-MRI is useful for monitoring disease progression.

  14. Radiofrequency ablation of liver cancer: early evaluation of therapeutic response with contrast-enhanced ultrasonography

    International Nuclear Information System (INIS)

    Choi, Dong Gil; Lim, Hyo K.; Lee, Won Jae; Kim, Seung Hoon; Kim, Min Ju; Kim, Seung Kwon; Jang, Kyung Mi; Lee, Ji Yeon; Lim, Jae Hoon

    2004-01-01

    The early assessment of the therapeutic response after percutaneous radiofrequency (RF) ablation is important, in order to correctly decide whether further treatment is necessary. The residual unablated tumor is usually depicted on contrast-enhanced multiphase helical computed tomography (CT) as a focal enhancing structure during the arterial and portal venous phases. Contrast-enhanced color Doppler and power Doppler ultrasonography (US) have also been used to detect residual tumors. Contrast-enhanced gray-scale US, using a harmonic technology which has recently been introduced, allows for the detection of residual tumors after ablation, without any of the blooming or motion artifacts usually seen on contrast-enhanced color or power Doppler US. Based on our experience and reports in the literature, we consider that contrast-enhanced gray-scale harmonic US constitutes a reliable alternative to contrast-enhanced multiphase CT for the early evaluation of the therapeutic response to RF ablation for liver cancer. This technique was also useful in targeting any residual unablated tumors encountered during additional ablation

  15. Solitary pulmonary nodules: Impact of quantitative contrast-enhanced CT on the cost-effectiveness of FDG-PET

    International Nuclear Information System (INIS)

    Comber, L.A.; Keith, C.J.; Griffiths, M.; Miles, K.A.

    2003-01-01

    AIM: To determine the impact of quantitative contrast-enhanced computed tomography (QECT) on the cost-effectiveness of diagnostic strategies for the assessment of solitary pulmonary nodules (SPNs). MATERIALS AND METHODS: Four diagnostic strategies were evaluated using decision tree analysis: conventional CT alone; conventional CT followed by QECT; conventional CT followed positron emission tomography (PET); and conventional CT followed by QECT and PET (QECT+PET). The average cost per patient, accuracy of management and incremental cost:accuracy ratio (ICAR) were determined for each strategy. Although baseline assumptions reflected the Australian setting, sensitivity analysis was used to extrapolate the results to the UK. RESULTS: At the baseline prevalence of malignancy (54%) and cost of PET relative to surgery (16%), the QECT strategy incurs the least cost ($5560/patient) but the QECT+PET strategy is the most cost-effective (ICAR $12059/patient). At reported levels of disease prevalence (68.5%) and cost of PET relative to surgery (29.9%) in the UK, the QECT strategy is the most cost-effective. CONCLUSION: QECT offers a cost-effective approach to evaluation of SPNs. Whether QECT is used alone or in combination with PET will depend upon local availability and regional values for prior probability of malignancy within SPNs and the cost of PET relative to surgery

  16. Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Coche, E.E.; Hammer, F.D.; Goffette, P.P. [Dept. of Radiology, St. Luc University Hospital, Brussels (Belgium)

    2001-11-01

    The authors report a case of successful detection of pulmonary embolism using gadolinium-enhanced spiral CT (Gadodiamide, 0.4 mmol/kg, 2 ml/s, delay 18 s) in a 77-year-old woman, with previous allergy to iodinated contrast medium, and renal failure, who presented with pulmonary arterial hypertension. Doppler ultrasound of the lower limbs was first performed and revealed a deep venous thrombosis of the right lower limb. To establish if venous thrombosis was the cause of pulmonary hypertension and to confirm that pulmonary endarterectomy was not indicated in this situation, several imaging modalities were performed. Lung scintigraphy and MRI were non-diagnostic. Gadolinium-enhanced spiral CT demonstrated a large thrombus located proximally and in a segmental artery of the right lower lobe. This case illustrates the potential usefulness of gadolinium as alternative contrast agent with spiral CT to diagnose pulmonary embolism and elucidate the cause of pulmonary arterial hypertension in a patient with some contraindications for iodinated contrast medium injection. (orig.)

  17. Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT

    International Nuclear Information System (INIS)

    Coche, E.E.; Hammer, F.D.; Goffette, P.P.

    2001-01-01

    The authors report a case of successful detection of pulmonary embolism using gadolinium-enhanced spiral CT (Gadodiamide, 0.4 mmol/kg, 2 ml/s, delay 18 s) in a 77-year-old woman, with previous allergy to iodinated contrast medium, and renal failure, who presented with pulmonary arterial hypertension. Doppler ultrasound of the lower limbs was first performed and revealed a deep venous thrombosis of the right lower limb. To establish if venous thrombosis was the cause of pulmonary hypertension and to confirm that pulmonary endarterectomy was not indicated in this situation, several imaging modalities were performed. Lung scintigraphy and MRI were non-diagnostic. Gadolinium-enhanced spiral CT demonstrated a large thrombus located proximally and in a segmental artery of the right lower lobe. This case illustrates the potential usefulness of gadolinium as alternative contrast agent with spiral CT to diagnose pulmonary embolism and elucidate the cause of pulmonary arterial hypertension in a patient with some contraindications for iodinated contrast medium injection. (orig.)

  18. Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2011-01-01

    A practical body-size adaptive protocol providing uniform image noise at various kV levels is not available for pediatric CT. To develop a practical contrast-enhanced pediatric chest CT protocol providing uniform image noise by using an individualized volume CT dose index (CTDIvol) determined by the cross-sectional area and density of the body at variable kV levels and with combined tube current modulation. A total of 137 patients (mean age, 7.6 years) underwent contrast-enhanced pediatric chest CT based on body weight. From the CTDIvol, image noise, and area and mean density of the cross-section at the lung base in the weight-based group, the best fit equation was estimated with a very high correlation coefficient (γ 2 = 0.86, P 2 vs. 326.3 ± 124.8 cm 2 ), mean density (-212.9 ± 53.1 HU vs. -221.1 ± 56.3 HU), and image noise (13.8 ± 2.3 vs. 13.6 ± 1.7 HU) between the weight-based and the CTDIvol groups (P > 0.05). Contrast-enhanced pediatric chest CT with the CTDIvol determined individually by the cross-sectional area and density of the body provides more uniform noise and better dose adaptation to body habitus than does weight-based CT at variable kV levels and with combined tube current modulation. (orig.)

  19. Comparison of arterial input functions measured from ultra-fast dynamic contrast enhanced MRI and dynamic contrast enhanced computed tomography in prostate cancer patients

    Science.gov (United States)

    Wang, Shiyang; Lu, Zhengfeng; Fan, Xiaobing; Medved, Milica; Jiang, Xia; Sammet, Steffen; Yousuf, Ambereen; Pineda, Federico; Oto, Aytekin; Karczmar, Gregory S.

    2018-02-01

    The purpose of this study was to evaluate the accuracy of arterial input functions (AIFs) measured from dynamic contrast enhanced (DCE) MRI following a low dose of contrast media injection. The AIFs measured from DCE computed tomography (CT) were used as ‘gold standard’. A total of twenty patients received CT and MRI scans on the same day. Patients received 120 ml Iohexol in DCE-CT and a low dose of (0.015 mM kg-1) of gadobenate dimeglumine in DCE-MRI. The AIFs were measured in the iliac artery and normalized to the CT and MRI contrast agent doses. To correct for different temporal resolution and sampling periods of CT and MRI, an empirical mathematical model (EMM) was used to fit the AIFs first. Then numerical AIFs (AIFCT and AIFMRI) were calculated based on fitting parameters. The AIFMRI was convolved with a ‘contrast agent injection’ function (AIFMRICON ) to correct for the difference between MRI and CT contrast agent injection times (~1.5 s versus 30 s). The results show that the EMMs accurately fitted AIFs measured from CT and MRI. There was no significant difference (p  >  0.05) between the maximum peak amplitude of AIFs from CT (22.1  ±  4.1 mM/dose) and MRI after convolution (22.3  ±  5.2 mM/dose). The shapes of the AIFCT and AIFMRICON were very similar. Our results demonstrated that AIFs can be accurately measured by MRI following low dose contrast agent injection.

  20. Oral contrast medium in PET/CT: should you or shouldn't you?

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Dickson, John C.; Townsend, Caroline; Croasdale, Ian; Syed, Rizwan; Nagabushan, Nagesh; Hain, Sharon F.; Ell, Peter J.; Bomanji, Jamshed B.

    2005-01-01

    It has been suggested that the use of computed tomography (CT) positive contrast agents has led to attenuation-induced artefacts on 18 F-fluorodeoxyglucose positron emission tomography ( 18 F-FDG PET/CT) systems. Consequently, centres may withhold the use of such agents. Whilst there is theoretical evidence to support the aforementioned claim, the clinical relevance of the induced artefacts has not been widely established. Moreover, the potential benefits of bowel enhancement on PET/CT have yet to be formally evaluated. We therefore prospectively examined PET/CT studies to assess whether the use of oral contrast medium induces clinically relevant artefacts and whether the use of these agents is diagnostically helpful. Over a 2-month period, 18 F-FDG PET/CT images were prospectively reviewed from 200 patients following Gastrografin administration 2 h prior to examination. Both a radiologist and a nuclear medicine physician reviewed the images for contrast medium-mediated clinically relevant artefacts. Artefacts were sought on the CT attenuation-corrected images and were compared with the appearance on non-attenuated-corrected images. The number of examinations in which the oral contrast aided image interpretation was also noted. There were no oral contrast medium-induced clinically significant artefacts. In 38 of the 200 patients, oral contrast aided image interpretation (owing to differentiation of mass/node from bowel, discrimination of intestinal wall from lumen or definition of the anatomy of a relevant site). In 33 of these 38 patients, the anatomical site of interest was the abdomen/pelvis. The use of oral contrast medium in 18 F-FDG PET studies should not be withheld as it improves image interpretation and does not produce clinically significant artefacts. (orig.)

  1. The 'humble' bubble: Contrast-enhanced ultrasound

    International Nuclear Information System (INIS)

    Marshall, Gill; Sykes, Anne; Berry, Jonathan; Jonker, Leon

    2011-01-01

    The use of contrast-enhanced ultrasound (CEUS) is increasing within the field of medical imaging. Ultrasonic contrast agent (UCA) contain gas microbubbles similar in size to red corpuscles which provide highly reflective interfaces, enabling dynamic demonstration of echogenic streams of the contrast within the anatomical area of interest on real-time grey scale ultrasound. Longevity of the microbubbles has been improved by changing their composition. The application of CEUS in the UK continues to grow, bringing it into territories historically occupied by computerised tomography (CT) scanning and magnetic resonance imaging (MRI). Hence, the role of CEUS may be of interest to all diagnostic imaging practitioners. Here we summarise the mode of action and use of CEUS, and its role within a range of applications. The potential risks of CEUS are compared to other contrast-enhanced imaging techniques. The benefits of CEUS and its implications for diagnostic imaging practice are also covered.

  2. Dual-phase contrast enhancement multi-slice CT in grading pancreatic neuroendocrine tumors

    International Nuclear Information System (INIS)

    Zhou Yan; Liu Jianyu; Zhu Xiang

    2013-01-01

    Objective: To evaluate characteristic clinical and imaging findings of pancreatic neuroendocrine tumors (NET) in dual-phase contrast enhancement MSCT. Methods: The dual-phase contrast enhancement MSCT images of 23 lesions in 20 patients with histologically confirmed pancreatic NET were studied retrospectively. Their clinical presentations, imaging characters as well as the intensities of lesions and normal pancreas in each phase were measured, and the following indices were calculated. First, the absolute enhancement of lesions, including the increasing of CT value of the maximum enhancement area within a tumor in arterial phase, that was named A1 in short, and that of the minimum enhancement area was labeled as A2. The same ROI measured increasing CT values in portal venous phase was labeled as V1 and V2 respectively. Secondly, the relatively enhancement indices comparing with the normal pancreas in the same patient within the same phase were calculated. This included the differences between the maximum, as well as the minimum, enhancement areas of tumors and the normal pancreas in arterial phase, which was named as AP1 and AP2 respectively, and those differences in portal venous phase, which were labeled as VP1 and VP2 respectively. All of the tumors were graded as G1 to G3 according to the WHO classification in 2010. A Kruskal Wallis test were performed to compare differences of tumor diameters and the enhancement indices. The change trend of enhancement indices varying with pathology grading were described. Fisher exact test was used to find differences of clinical and imaging characters. Results: Twenty-three lesions in 20 patients included 13 lesions in grade 1 (G1), 8 in G2, and 2 in G3. Among the 10 patients with G1 NET, 7 of them had no endocrine symptoms, while the other 3 had endocrine symptoms. Six of them had no abdominal pain, while 4 of them complained of it. All of the 10 patients with G1 NET had no hepatic metastasis. Among 8 patients with G2 NET

  3. Dual Contrast CT Method Enables Diagnostics of Cartilage Injuries and Degeneration Using a Single CT Image.

    Science.gov (United States)

    Saukko, Annina E A; Honkanen, Juuso T J; Xu, Wujun; Väänänen, Sami P; Jurvelin, Jukka S; Lehto, Vesa-Pekka; Töyräs, Juha

    2017-12-01

    Cartilage injuries may be detected using contrast-enhanced computed tomography (CECT) by observing variations in distribution of anionic contrast agent within cartilage. Currently, clinical CECT enables detection of injuries and related post-traumatic degeneration based on two subsequent CT scans. The first scan allows segmentation of articular surfaces and lesions while the latter scan allows evaluation of tissue properties. Segmentation of articular surfaces from the latter scan is difficult since the contrast agent diffusion diminishes the image contrast at surfaces. We hypothesize that this can be overcome by mixing anionic contrast agent (ioxaglate) with bismuth oxide nanoparticles (BINPs) too large to diffuse into cartilage, inducing a high contrast at the surfaces. Here, a dual contrast method employing this mixture is evaluated by determining the depth-wise X-ray attenuation profiles in intact, enzymatically degraded, and mechanically injured osteochondral samples (n = 3 × 10) using a microCT immediately and at 45 min after immersion in contrast agent. BiNPs were unable to diffuse into cartilage, producing high contrast at articular surfaces. Ioxaglate enabled the detection of enzymatic and mechanical degeneration. In conclusion, the dual contrast method allowed detection of injuries and degeneration simultaneously with accurate cartilage segmentation using a single scan conducted at 45 min after contrast agent administration.

  4. Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2011-07-15

    A practical body-size adaptive protocol providing uniform image noise at various kV levels is not available for pediatric CT. To develop a practical contrast-enhanced pediatric chest CT protocol providing uniform image noise by using an individualized volume CT dose index (CTDIvol) determined by the cross-sectional area and density of the body at variable kV levels and with combined tube current modulation. A total of 137 patients (mean age, 7.6 years) underwent contrast-enhanced pediatric chest CT based on body weight. From the CTDIvol, image noise, and area and mean density of the cross-section at the lung base in the weight-based group, the best fit equation was estimated with a very high correlation coefficient ({gamma}{sup 2} = 0.86, P < 0.001). For the next study, 177 patients (mean age, 7.9 years; the CTDIvol group) underwent contrast-enhanced pediatric chest CT with the CTDIvol determined individually by the best fit equation. CTDIvol values on the dose report after CT scanning, noise differences from the target noise, areas, and mean densities were compared between these two groups. The CTDIvol values (mean{+-}standard deviation, 1.6 {+-} 0.7 mGy) and the noise differences from the target noise (1.1 {+-} 0.9 HU) of the CTDIvol group were significantly lower than those of the weight-based group (2.0 {+-} 1.0 mGy, 1.8 {+-} 1.4 HU) (P < 0.001). In contrast, no statistically significant difference was found in area (317.0 {+-} 136.8 cm{sup 2} vs. 326.3 {+-} 124.8 cm{sup 2}), mean density (-212.9 {+-} 53.1 HU vs. -221.1 {+-} 56.3 HU), and image noise (13.8 {+-} 2.3 vs. 13.6 {+-} 1.7 HU) between the weight-based and the CTDIvol groups (P > 0.05). Contrast-enhanced pediatric chest CT with the CTDIvol determined individually by the cross-sectional area and density of the body provides more uniform noise and better dose adaptation to body habitus than does weight-based CT at variable kV levels and with combined tube current modulation. (orig.)

  5. The optimal dose of the contrast media for spiral CT portography

    International Nuclear Information System (INIS)

    Zhang Jiansheng; Xiao Peiyu; Meng Xiaochun; Xu Chuan

    2007-01-01

    Objective: To investigate the optimal dose of the contrast media in SCTP. Methods: 40 healthy patients were divided into 2 groups according to their body weight (20 cases in group A with weight below 60kg, 20 cases in group B with weight over 70kg). They all received 90ml contrast media at a rate of 4.0 ml/sec in the contrast-enhanced CT ex- amination. And non-cirrhosis cases, liver cirrhosis without ascites cases and liver cirrhosis with ascites cases were selected respectively, 60 patients in each group. Then, the patients of each group were randomly divided into 3 sub-groups, 20 cases in each of them, which respectively received 1.5ml/kg, 2.0ml/kg, 2.5ml/kg contrast media at a rate of 4.0 ml/sec in the contrast-enhanced CT examination. The effect of the dose of the contrast material on the imaging quality of portal vein system in patients with different weight and different state of illness was analyzed. Results: In 40 healthy patients, the density difference between portal vein and hepatic parenchyma was significantly higher in Group A than in Group B (P 0.05), and both of them showed significant difference while using 1.5ml/kg contrast media (P 0.05), and they both had significant difference when using 1.5ml/kg contrast media (P< 0.05). Besides these, the imaging quality of portal vein branches and collateral vessels were better in 2.0ml/kg group than others. Conclusion: The patient's body weight and the state of liver disease influenced the extent of portal vein enhancement. To calculate the dose of contrast media according to patient's weight is crucial for ensuring the imaging quality of portal vein system. 2.0ml/kg contrast media can provide a better effect. (authors)

  6. A method to evaluate the dose increase in CT with iodinated contrast medium

    International Nuclear Information System (INIS)

    Amato, Ernesto; Lizio, Domenico; Settineri, Nicola; Di Pasquale, Andrea; Salamone, Ignazio; Pandolfo, Ignazio

    2010-01-01

    Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical protocols

  7. A method to evaluate the dose increase in CT with iodinated contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Amato, Ernesto; Lizio, Domenico; Settineri, Nicola; Di Pasquale, Andrea; Salamone, Ignazio; Pandolfo, Ignazio [Department of Radiological Sciences, University of Messina, Messina 98125 (Italy); Department of Physics, University of Messina, Messina 98166 (Italy); University Hospital ' ' G. Martino' ' , Messina 98125 (Italy); Department of Radiological Sciences, University of Messina, Messina 98125 (Italy) and University Hospital ' ' G. Martino' ' , Messina 98125 (Italy)

    2010-08-15

    Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical

  8. Utility of intravenous nonionic contrast media for abdominal CT in patients with renal dysfunction

    International Nuclear Information System (INIS)

    Craig, B.M.; Alpern, M.B.; Sandler, M.A.; Pearlberg, J.L.; Swanson, D.P.

    1987-01-01

    The safety and efficacy of a nonionic contrast medium (NICM) for CT enhancements in patients with renal dysfunction were evaluated. Thirty consecutive patients referred for abdominal CT with a serum creatinine (SCr) level over 5 mg/dL or a SCr level of 2-5 mg/dL and another risk factor (e.g., diabetes, single kidney) received NICM. Each was matched with a control who received the same 150-mL bolus of a conventional medium. No adverse reactions or significant alterations in SCr values were found in the NICM patients. No significant differences between the patient groups were found in blinded subjective image quality ratings or measured attenuation values of a parenchymal organs and vascular structures (with the exception of less renal enhancement in the NICM patients, reflecting their renal dysfunction). Use of an NICM is a safe and effective method for contrast medium-enhanced CT in patients with renal dysfunction

  9. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, Pierre-Alexandre, E-mail: Pierre-Alexandre.Poletti@hcuge.ch [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Buchs, Nicolas [Department of Surgery, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Shanmuganathan, Kathirkamanathan [Department of Diagnostic Radiology and Nuclear Medicine, 22 S. Greene Street, Baltimore, MD 21201 (United States); Platon, Alexandra [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland)

    2013-11-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT.

  10. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    International Nuclear Information System (INIS)

    Poletti, Pierre-Alexandre; Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain; Buchs, Nicolas; Shanmuganathan, Kathirkamanathan; Platon, Alexandra

    2013-01-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT

  11. Clinical observation of the adverse drug reactions caused by non-ionic iodinated contrast media: results from 109,255 cases who underwent enhanced CT examination in Chongqing, China.

    Science.gov (United States)

    Li, X; Chen, J; Zhang, L; Liu, H; Wang, S; Chen, X; Fang, J; Wang, S; Zhang, W

    2015-03-01

    To analyse the pattern and factors that influence the incidence of adverse drug reactions (ADRs) induced by non-ionic iodinated contrast media and to evaluate their safety profiles. Data from 109,255 cases who underwent enhanced CT examination from 1 January 2008 to 31 August 2013 were analysed. ADRs were classified according to the criteria issued by the American College of Radiology and the Chinese Society of Radiology. A total of 375 (0.34%) patients had ADRs, including 281 mild (0.26%); 80 moderate (0.07%); and 14 severe (0.01%) ADRs; no death was found. 302 (80.53%) of the ADRs occurred within 15 min after examination. Patients aged 40-49 years (204 cases, 0.43%; p contrast media are mainly mild ones, while moderate or severe ADRs are relatively rare, suggesting that enhanced CT examination with non-ionic iodinated contrast media is highly safe, and severe adverse events will seldom occur under appropriate care. The study included 109,255 patients enrolled in various types of enhanced CT examinations, which could reflect ADR conditions and regulations in Chinese population accurately and reliably.

  12. The effect of intravenous contrast on SUV value in 18F-FDG PET/CT using diagnostic high energy CT

    International Nuclear Information System (INIS)

    Jeong, Young Jin; Kang, Do Young

    2006-01-01

    According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT - 120 kVp, 130 mAs) scan. Than contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET emission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in all patients. Also pathologic lesions were investigated. There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p < 0.001). The maxSUV was 1.1 ± 0.5 in PET images with CECT-corrected attenuation and 1.0 ± 0.5 in PET images with NCCT-corrected attenuation. The limit of agreement was 0.1 ± 0.3 in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 and segment 8 of the liver and spleen (p <0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p < 0.001). The maxSUV was 4.7 ± 2.0 in PET images with CECT-corrected attenuation and 4.4 ± 2.0 in PET images with NCCT- corrected attenuation. The limit of agreement was 0.4 ± 0.8 in Bland-Altman analysis. Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of

  13. Acute anterior myocardial infarction seen on conventional iodine-contrast CT

    Directory of Open Access Journals (Sweden)

    Christian Hagdrup, MD

    2017-09-01

    Full Text Available Diagnosis of acute myocardial infarction (AMI is based on clinical symptoms of chest pain and dyspnea in combination with electrocardiographic changes and a raise in myocardial-specific biomarkers. Imaging is by echocardiography and magnetic resonance. The preferred technique for identification of previous myocardial infarction (MI is magnetic resonance imaging with late gadolinium technique, but in the acute patient echocardiography is applied. In selected cases, important information can be obtained from other imaging modalities. We describe a case of a patient first suspected of an abdominal catastrophe in whom acute MI was diagnosed from a computerized tomography (CT scan with iodine contrast. Our case together with a few other cases reported in the literature demonstrate that contrast enhancement of the myocardium can be important to follow in the acute patient because the CT scans sometimes give a unique opportunity to recognize findings consistent with MI even though the CT scan was performed for another reason.

  14. Experiences of using a single post-contrast CT scan of the urinary tract after triphasic contrast injection

    Directory of Open Access Journals (Sweden)

    Phillip Carl Pretorius

    2011-12-01

    Full Text Available I was alerted to an article in Radiology Vol. 255 No. 2 (May 20101 by a colleague. The article, entitled ‘Kidney and urinary tract imaging: Triple-bolus multidetector CT urography as a one-stop shop – Protocol design, opacification, and image quality analysis’, clearly describes the technique, while the quotation below, from the article, summarises the findings: ‘We have shown that triple-bolus multidetector CT urography allowed visualization of renal parenchymal, excretory, and vascular contrast-enhancement phases in a single dose-efficient acquisition and provided sufficient opacification of the UUT, with simultaneous and adequate image quality of renal parenchyma and vascular anatomy.’ The main emphasis on this technique is to reduce the number of unnecessary CT scans when assessing the urinary tract. Our previous protocol for scanning the urinary tract for pathology included four phases: a pre-contrast, corticomedullary, nephrographic and delay excretory phase.

  15. Hepatic blood perfusion estimated by dynamic contrast-enhanced computed tomography in pigs

    DEFF Research Database (Denmark)

    Winterdahl, Michael; Sørensen, Michael; Keiding, Inger Susanne

    2012-01-01

    The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates.......The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates....

  16. Myocardial enhancement pattern in patients with acute myocardial infarction on two-phase contrast-enhanced Ecg-gated multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Ko, S.M.; Seo, J.B.; Hong, M.K.; Do, K.H.; Lee, S.H.; Lee, J.S.; Song, J.W.; Park, S.J.; Park, S.W.; Lim, T.H.

    2006-01-01

    Aim: To evaluate the myocardial enhancement pattern of the left ventricle on two-phase contrast-enhanced electrocardiogram (ECG)-gated multidetector computed tomography (MDCT) images in patients with acute myocardial infarction (AMI). METHODS: Two-phase contrast-enhanced ECG-gated MDCT examinations were performed in 16 patients with AMI. The presence, location and pattern of myocardial enhancement were evaluated. MDCT findings were compared with the catheter angiographic results. RESULTS: Subendocardial (n=9) or transmural (n=6) area of early perfusion defects of the myocardium was detected in 15 of 16 patients (94%) on early-phase CT images. Variable delayed myocardial enhancement patterns on late-phase CT images were observed in 12 patients (75%): (1) subendocardial residual perfusion defect and subepicardial late enhancement (n=6); (2) transmural late enhancement (n=1); (3) isolated subendocardial late enhancement (n=1); and (4) isolated subendocardial residual perfusion defect (n=2). On catheter angiography, 14 of 15 corresponding coronary arteries showed significant stenosis. CONCLUSION: Variable abnormal myocardial enhancement pattern was seen on two-phase, contrast-enhanced ECG-gated MDCT in patients with AMI. Assessment of myocardial attenuation on CT angiography gives additional information of the location and extent of infarction

  17. Effect of different saline chaser volumes and flow rates on intravascular contrast enhancement in CT using a circulation phantom

    International Nuclear Information System (INIS)

    Behrendt, Florian F.; Bruners, Philipp; Keil, Sebastian; Plumhans, Cedric; Mahnken, Andreas H.; Das, Marco; Ackermann, Diana; Guenther, Rolf W.; Muehlenbruch, Georg

    2010-01-01

    Purpose: To evaluate the influence of different saline chaser volumes and different saline chaser flow rates on the intravascular contrast enhancement in MDCT. Materials and methods: In a physiological flow phantom contrast medium (120 ml, 300 mgI/ml, Ultravist 300) was administered at a flow rate of 6 ml/s followed by different saline chaser volumes (0, 30, 60 and 90 ml) at the same injection rate or followed by a 30-ml saline chaser at different injection rates (2, 4, 6 and 8 ml/s). Serial CT-scans at a level covering the pulmonary artery, the ascending and the descending aorta replica were obtained. Time-enhancement curves were computed and both pulmonary and aortic peak enhancement and peak time were determined. Results: Compared to contrast medium injection without a saline chaser the pushing with a saline chaser (30, 60, and 90 ml) resulted in a statistically significant increased pulmonary peak enhancement (all p = 0.008) and prolonged peak time (p = 0.032, p = 0.024 and p = 0.008, respectively). Highest aortic peak enhancement values were detected for a saline chaser volume of 30 ml. A saline chaser flow rate of 8 ml/s resulted in the highest pulmonary peak enhancement values compared to flow rates of 2, 4 and 6 ml/s (all p = 0.008). Aortic peak enhancement showed the highest values for a flow rate of 6 ml/s. Conclusion: A saline chaser volume of 30 ml and an injection rate of 6 ml/s are sufficient to best improve vascular contrast enhancement in the pulmonary artery and the aorta in MDCT.

  18. MRI and CT contrast media extravasation

    Science.gov (United States)

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H.; Prince, Martin R.

    2018-01-01

    Abstract Background: This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Methods: Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Results: Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Conclusion: Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT. PMID:29489663

  19. Comparison of post contrast CT urography phases in bladder cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Helenius, Malin; Dahlman, Par; Lonnemark, Maria; Magnusson, Anders [Uppsala University Hospital, Department of Surgical Sciences, Section of Radiology, Uppsala (Sweden); Brekkan, Einar [Uppsala University Hospital, Department of Surgical Sciences, Section of Urology, Uppsala (Sweden); Wernroth, Lisa [Uppsala University Hospital, Uppsala Clinical Research Center, Uppsala (Sweden)

    2016-02-15

    The aim of this study was to investigate which post-contrast phase(s) in a four-phase CT urography protocol is (are) most suitable for bladder cancer detection. The medical records of 106 patients with visible haematuria who underwent a CT urography examination, including unenhanced, enhancement-triggered corticomedullary (CMP), nephrographic (NP) and excretory (EP) phases, were reviewed. The post-contrast phases (n = 318 different phases) were randomized into an evaluation order and blindly reviewed by two uroradiologists. Twenty-one patients were diagnosed with bladder cancer. Sensitivity for bladder cancer detection was 0.95 in CMP, 0.83 in NP and 0.81 in EP. Negative predictive value (NPV) was 0.99 in CMP, 0.96 in NP and 0.95 in EP. The sensitivity was higher in CMP than in both NP (p-value 0.016) and EP (p-value 0.0003). NPV was higher in CMP than in NP (p-value 0.024) and EP (p-value 0.002). In the CT urography protocol with enhancement-triggered scan, sensitivity and NPV were highest in the corticomedullary phase, and this phase should be used for bladder assessment. (orig.)

  20. Comparison of post contrast CT urography phases in bladder cancer detection

    International Nuclear Information System (INIS)

    Helenius, Malin; Dahlman, Par; Lonnemark, Maria; Magnusson, Anders; Brekkan, Einar; Wernroth, Lisa

    2016-01-01

    The aim of this study was to investigate which post-contrast phase(s) in a four-phase CT urography protocol is (are) most suitable for bladder cancer detection. The medical records of 106 patients with visible haematuria who underwent a CT urography examination, including unenhanced, enhancement-triggered corticomedullary (CMP), nephrographic (NP) and excretory (EP) phases, were reviewed. The post-contrast phases (n = 318 different phases) were randomized into an evaluation order and blindly reviewed by two uroradiologists. Twenty-one patients were diagnosed with bladder cancer. Sensitivity for bladder cancer detection was 0.95 in CMP, 0.83 in NP and 0.81 in EP. Negative predictive value (NPV) was 0.99 in CMP, 0.96 in NP and 0.95 in EP. The sensitivity was higher in CMP than in both NP (p-value 0.016) and EP (p-value 0.0003). NPV was higher in CMP than in NP (p-value 0.024) and EP (p-value 0.002). In the CT urography protocol with enhancement-triggered scan, sensitivity and NPV were highest in the corticomedullary phase, and this phase should be used for bladder assessment. (orig.)

  1. Baseline incidence and severity of renal insufficiency evaluated by estimated glomerular filtration rates in patients scheduled for contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Utsunomiya, Daisuke; Yanaga, Yumi; Oda, Seitaro; Namimoto, Tomohiro; Yamashita, Yasuyuki (Dept. of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto Univ., Kumamoto (Japan)), email: utsunomi@kumamoto-u.ac.jp; Awai, Kazuo (Dept. of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima Univ., Hiroshima (Japan)); Funama, Yoshinori (Dept. of Medical Physics, Faculty of Life Sciences, Kumamoto Univ., Kumamoto (Japan))

    2011-06-15

    Background Although pre-existing renal insufficiency (RI) is the most important risk factor for contrast-induced nephropathy (CIN), the background distribution of baseline renal function has not been investigated thoroughly in patients scheduled for contrast-enhanced CT. Purpose To investigate the incidence and severity of baseline RI evaluated by estimated glomerular filtration rates (eGFR) in patients who underwent contrast-enhanced CT at an academic center. Material and Methods A total of 6586 patients (3630 men and 2956 women; mean age 57.0 +- 11.9 years) who underwent contrast-enhanced CT between January and December 2008 were retrospectively studied. Of these, 829 had cardiovascular diseases (CVD), 5116 had oncologic diseases, 178 had diabetes mellitus (DM), and 1572 had chronic liver disease (CLD). The eGFR (mL/min/1.73 m2) was calculated from their serum creatinine level. Mild, moderate-a, moderate-b, and severe RI were recorded at 60 < =eGFR < 90, 45 < =eGFR < 60, 30 < =eGFR < 45 and eGFR < 30, respectively. Results Of the 6586 patients, 1.6%, 3.7%, 13.7%, and 54.2% were judged to present with severe, moderate-b, moderate-a, and mild RI, respectively. While moderate-b-to-severe RI was recorded in 133 (3.2%) of 4161 patients aged 70 years or less, it was observed in 218 (9.0%) of the 2425 patients who were 71 years or older. Among the 829 CVD patients, 9.9% manifested moderate-b-to-severe- and 73.0% mild-to-moderate-a RI. The corresponding rates were 4.4% and 68.9% for oncologic disease, 16.9% and 61.2% for DM, and 4.8% and 71.5% for CLD patients. By univariate analysis, there was a significant association between moderate-b-to-severe RI and the advanced age, CVD, DM, and non-oncologic disease. Multivariate analysis showed that the advanced age, DM, and non-oncologic disease were statistically associated with moderate-b-to-severe RI. Conclusion The incidence of RI of eGFR < 45mL/min/1.73 m2 at baseline was high in patients with advanced age, CVD and DM and

  2. Contrast Enhancement Method Based on Gray and Its Distance Double-Weighting Histogram Equalization for 3D CT Images of PCBs

    Directory of Open Access Journals (Sweden)

    Lei Zeng

    2016-01-01

    Full Text Available Cone beam computed tomography (CBCT is a new detection method for 3D nondestructive testing of printed circuit boards (PCBs. However, the obtained 3D image of PCBs exhibits low contrast because of several factors, such as the occurrence of metal artifacts and beam hardening, during the process of CBCT imaging. Histogram equalization (HE algorithms cannot effectively extend the gray difference between a substrate and a metal in 3D CT images of PCBs, and the reinforcing effects are insignificant. To address this shortcoming, this study proposes an image enhancement algorithm based on gray and its distance double-weighting HE. Considering the characteristics of 3D CT images of PCBs, the proposed algorithm uses gray and its distance double-weighting strategy to change the form of the original image histogram distribution, suppresses the grayscale of a nonmetallic substrate, and expands the grayscale of wires and other metals. The proposed algorithm also enhances the gray difference between a substrate and a metal and highlights metallic materials. The proposed algorithm can enhance the gray value of wires and other metals in 3D CT images of PCBs. It applies enhancement strategies of changing gray and its distance double-weighting mechanism to adapt to this particular purpose. The flexibility and advantages of the proposed algorithm are confirmed by analyses and experimental results.

  3. Bosniak classification system: a prospective comparison of CT, contrast-enhanced US, and MR for categorizing complex renal cystic masses.

    Science.gov (United States)

    Graumann, Ole; Osther, Susanne Sloth; Karstoft, Jens; Hørlyck, Arne; Osther, Palle Jörn Sloth

    2016-11-01

    Background The Bosniak classification was originally based on computed tomographic (CT) findings. Magnetic resonance (MR) and contrast-enhanced ultrasonography (CEUS) imaging may demonstrate findings that are not depicted at CT, and there may not always be a clear correlation between the findings at MR and CEUS imaging and those at CT. Purpose To compare diagnostic accuracy of MR, CEUS, and CT when categorizing complex renal cystic masses according to the Bosniak classification. Material and Methods From February 2011 to June 2012, 46 complex renal cysts were prospectively evaluated by three readers. Each mass was categorized according to the Bosniak classification and CT was chosen as gold standard. Kappa was calculated for diagnostic accuracy and data was compared with pathological results. Results CT images found 27 BII, six BIIF, seven BIII, and six BIV. Forty-three cysts could be characterized by CEUS, 79% were in agreement with CT (κ = 0.86). Five BII lesions were upgraded to BIIF and four lesions were categorized lower with CEUS. Forty-one lesions were examined with MR; 78% were in agreement with CT (κ = 0.91). Three BII lesions were upgraded to BIIF and six lesions were categorized one category lower. Pathologic correlation in six lesions revealed four malignant and two benign lesions. Conclusion CEUS and MR both up- and downgraded renal cysts compared to CT, and until these non-radiation modalities have been refined and adjusted, CT should remain the gold standard of the Bosniak classification.

  4. Preliminary study on the differentiation between parapelvic cyst and hydronephrosis with non-calculous using only pre-contrast dual-energy spectral CT scans

    Science.gov (United States)

    Han, Dong; Ma, Guangming; Wei, Lequn; Ren, Chenglong; Zhou, Jieli; Shen, Chen

    2017-01-01

    Objective: To investigate the value of using the quantitative parameters from only the pre-contrast dual-energy spectral CT imaging for distinguishing between parapelvic cyst and hydronephrosis with non-calculous (HNC). Methods: This retrospective study was approved by the institutional review board. 28 patients with parapelvic cyst and 24 patients with HNC who underwent standard pre-contrast and multiphase contrast-enhanced dual-energy spectral CT imaging were retrospectively identified. The parapelvic cyst and HNC were identified using the contrast-enhanced scans, and their CT number in the 70-keV monochromatic images, effective atomic number (Zeff), iodine concentration (IC) and water concentration in the pre-contrast images were measured. The slope of the spectral curve (λ) was calculated. The difference in the measurements between parapelvic cyst and HNC was statistically analyzed using SPSS® v. 19.0 (IBM Corp., New York, NY; formerly SPSS Inc., Chicago, IL) statistical software. Receiver-operating characteristic analysis was performed to assess the diagnostic performance. Results: The CT numbers in the 70-keV images, Zeff and IC values were statistically different between parapelvic cyst and HNC (all p  0.05). Conclusion: The quantitative parameters obtained in the pre-contrast dual-energy spectral CT imaging may be used to differentiate between parapelvic cyst and HNC. Advances in knowledge: The pre-contrast dual-energy spectral CT scans may be used to screen parapelvic cysts for patients who are asymptomatic, thereby avoiding contrast-enhanced CT or CT urography examination for these patients to reduce ionizing radiation dose and contrast dose. PMID:28281789

  5. Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver?

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hiroto; Okada, Masahiro; Hyodo, Tomoko; Hidaka, Syojiro; Kagawa, Yuki; Matsuki, Mitsuru; Tsurusaki, Masakatsu; Murakami, Takamichi, E-mail: murakami@med.kindai.ac.jp

    2014-04-15

    Purpose: To investigate whether low-dose dynamic CT of the liver with iterative reconstruction can reduce both the radiation dose and the amount of contrast medium. Materials and methods: This study was approved by our institutional review board. 113 patients were randomly assigned to one of two groups. Group A/group B (fifty-eight/fifty-five patients) underwent liver dynamic CT at 120/100 kV, with 0/40% adaptive statistical iterative reconstruction (ASIR), with a contrast dose of 600/480 mg I/kg, respectively. Radiation exposure was estimated based on the manufacturer's phantom data. The enhancement value of the hepatic parenchyma, vessels and the tumor-to-liver contrast of hepatocellular carcinomas (HCCs) were compared between two groups. Two readers independently assessed the CT images of the hepatic parenchyma and HCCs. Results: The mean CT dose indices: 6.38/4.04 mGy, the dose-length products: 194.54/124.57 mGy cm, for group A/group B. The mean enhancement value of the hepatic parenchyma and the tumor-to-liver contrast of HCCs with diameters greater than 1 cm in the post-contrast all phases did not differ significantly between two groups (P > 0.05). The enhancement values of vessels in group B were significantly higher than that in group A in the delayed phases (P < 0.05). Two reader's confidence levels for the hepatic parenchyma in the delayed phases and HCCs did not differ significantly between the groups (P > 0.05). Conclusions: Low-dose dynamic CT with ASIR can reduce both the radiation dose and the amount of contrast medium without image quality degradation, compared to conventional dynamic CT without ASIR.

  6. Myocardial delayed-enhancement CT: initial experience in children and young adults

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2017-10-15

    Clinical utility of myocardial delayed enhancement CT has not been reported in children and young adults. To describe initial experience of myocardial delayed enhancement CT regarding image quality, radiation dose and identification of myocardial lesions in children and young adults. Between August 2013 and November 2016, 29 consecutive children and young adults (median age 16 months) with suspected coronary artery or myocardial abnormality underwent arterial- and delayed-phase cardiac CT at our institution. We measured CT densities in normal myocardium, left ventricular cavity, and arterial and delayed hypo-enhancing and delayed hyperenhancing myocardial lesions. We then compared the extent of delayed hyperenhancing lesions with delayed-enhancement MRI or thallium single-photon emission CT. Normal myocardium and left ventricular cavity showed significantly higher CT numbers on arterial-phase CT than on delayed-phase CT (t-test, P<0.0001). Contrast-to-noise ratios of the arterial and delayed hypo-enhancing and delayed hyperenhancing lesions on CT were 26.7, 17.6 and 18.7, respectively. Delayed-phase CT findings were equivalent to those of delayed-enhancement MRI in all cases (7/7) and to those of thallium single-photon emission CT in 70% (7/10). Myocardial delayed-enhancement CT can be added to evaluate myocardial lesions in select children and young adults with suspected coronary artery or myocardial abnormality. (orig.)

  7. Myocardial delayed-enhancement CT: initial experience in children and young adults

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2017-01-01

    Clinical utility of myocardial delayed enhancement CT has not been reported in children and young adults. To describe initial experience of myocardial delayed enhancement CT regarding image quality, radiation dose and identification of myocardial lesions in children and young adults. Between August 2013 and November 2016, 29 consecutive children and young adults (median age 16 months) with suspected coronary artery or myocardial abnormality underwent arterial- and delayed-phase cardiac CT at our institution. We measured CT densities in normal myocardium, left ventricular cavity, and arterial and delayed hypo-enhancing and delayed hyperenhancing myocardial lesions. We then compared the extent of delayed hyperenhancing lesions with delayed-enhancement MRI or thallium single-photon emission CT. Normal myocardium and left ventricular cavity showed significantly higher CT numbers on arterial-phase CT than on delayed-phase CT (t-test, P<0.0001). Contrast-to-noise ratios of the arterial and delayed hypo-enhancing and delayed hyperenhancing lesions on CT were 26.7, 17.6 and 18.7, respectively. Delayed-phase CT findings were equivalent to those of delayed-enhancement MRI in all cases (7/7) and to those of thallium single-photon emission CT in 70% (7/10). Myocardial delayed-enhancement CT can be added to evaluate myocardial lesions in select children and young adults with suspected coronary artery or myocardial abnormality. (orig.)

  8. Fat-saturated, contrast-enhanced spin echo sequences in magnetic resonance tomographic diagnosis of peritoneal carcinosis

    International Nuclear Information System (INIS)

    Ricke, J.; Hosten, N.; Stroszczynski, C.; Amthauer, H.; Felix, R.; Sehouli, J.; Buchmann, E.; Rieger, J.

    1999-01-01

    Purpose: To evaluate contrast-enhanced, fat-saturated spin echo sequences for the detection of peritoneal carcinosis with MRI. Material and Methods: 61 patients, 35 with and 26 without peritoneal carcinosis, were examined with abdominal MRI. Fat-saturated, T 1 -weighted spin echo sequences were performed before and after administration of Gd-DTPA. In addition, 22 patients with peritoneal carcinosis were examined with contrast-enhanced abdominal CT. Results: 32 of 35 patients with peritoneal carcinosis demonstrated contrast enhancement of the visceral and 30 to 35 enhancement of the parietal peritoneum (91 and 86%, respectively). Wall thickening of the intestine or parietal peritoneum were noted in 21 and 20 of 35 patients (60 and 57%, respectively), ascites in 18 of 35 patients (51%). False positive contrast enhancement of the peritoneum was noted in 4 of 26 patients (15%). In the direct comparison of MRI and CT, 22 of 22 patients versus 7 of 22 patients showed contrast enhancement of the visceral peritoneum (100 and 32%, respectively). For other signs of peritoneal carcinosis (e.g., ascites, peritoneal seedings), no differences in diagnostic reliability were demonstrated. Conclusions: The use of fat-saturated, spin echo sequences facilitates the diagnosis of peritoneal carcinosis by artifact reduction and improved detection of peritoneal contrast enhancement. MRI with fat-saturated sequences was superior to CT. (orig.) [de

  9. Polymer Assembly Encapsulation of Lanthanide Nanoparticles as Contrast Agents for In Vivo Micro-CT.

    Science.gov (United States)

    Cruje, Charmainne; Dunmore-Buyze, Joy; MacDonald, Jarret P; Holdsworth, David W; Drangova, Maria; Gillies, Elizabeth R

    2018-03-12

    Despite recent technological advancements in microcomputed tomography (micro-CT) and contrast agent development, preclinical contrast agents are still predominantly iodine-based. Higher contrast can be achieved when using elements with higher atomic numbers, such as lanthanides; lanthanides also have X-ray attenuation properties that are ideal for spectral CT. However, the formulation of lanthanide-based contrast agents at the high concentrations required for vascular imaging presents a significant challenge. In this work, we developed an erbium-based contrast agent that meets micro-CT imaging requirements, which include colloidal stability upon redispersion at high concentrations, evasion of rapid renal clearance, and circulation times of tens of minutes in small animals. Through systematic studies with poly(ethylene glycol) (PEG)-poly(propylene glycol), PEG-polycaprolactone, and PEG-poly(l-lactide) (PLA) block copolymers, the amphiphilic block copolymer PEG 114 -PLA 53 was identified to be ideal for encapsulating oleate-coated lanthanide-based nanoparticles for in vivo intravenous administration. We were able to synthesize a contrast agent containing 100 mg/mL of erbium that could be redispersed into colloidally stable particles in saline after lyophilization. Contrast enhancement of over 250 HU was achieved in the blood pool for up to an hour, thereby meeting the requirements of live animal micro-CT.

  10. Abnormal contrast enhancement after the removal of meningioma

    Energy Technology Data Exchange (ETDEWEB)

    Soutsu, M; Hashimoto, T; Yamaguchi, Y; Sekino, H; Nakamura, N [Jikei Univ., Tokyo (Japan). School of Medicine

    1980-12-01

    Since the introduction of Computerized Tomography (CT) in August, 1976, we have had experience with 20 patients with meningioma. In 10 patients out of the 20, the tumors were removed totally and examined by contrast-enhanced CT pre- and postoperatively. In spite of the total removal of the tumor, however, 5 patients showed an unexpected abnormal enhancement at the operated site after the infusion of a contrast material. These changes were relatively intense, so it was suspected that there were residual tumors. Comparing these 5 cases with the remaining 5 that had no postoperative enhancement, the former cases were shown by operative and angiographical findings to have more adhesion and connecting vessels between tumor and cortex. Since such a postoperative abnormal enhancement is seen along the corticotomy or retracted area after operations for and aneurysm or another lesion, damaged brain tissue was though to be the probable reason for this enhancement. Moreover, the circulatory change caused by cutting the connecting vessels between tumor and cortex was considered to be another reason for the enhancement. This mechanism was also considered to be one reason for the post-meningioma syndrome by El-Banhawy. These postoperative enhancements decreased in density and became obscure within 4 or 8 weeks. Any reappearance of such changes after that period should be examined, carefully to determine whether or not it marks a recurrent tumor.

  11. Tracer kinetic modelling of tumour angiogenesis based on dynamic contrast-enhanced CT and MRI measurements

    Energy Technology Data Exchange (ETDEWEB)

    Brix, Gunnar [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany); Bundesamt fuer Strahlenschutz (BfS), Abteilung fuer medizinischen und beruflichen Strahlenschutz, Oberschleissheim (Germany); Griebel, Juergen [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany); Kiessling, Fabian [RWTH-Aachen University, Department of Experimental Molecular Imaging, Aachen (Germany); Wenz, Frederik [University Medical Center Mannheim, University of Heidelberg, Department of Radiation Oncology, Mannheim (Germany)

    2010-08-15

    Technical developments in both magnetic resonance imaging (MRI) and computed tomography (CT) have helped to reduce scan times and expedited the development of dynamic contrast-enhanced (DCE) imaging techniques. Since the temporal change of the image signal following the administration of a diffusible, extracellular contrast agent (CA) is related to the local blood supply and the extravasation of the CA into the interstitial space, DCE imaging can be used to assess tissue microvasculature and microcirculation. It is the aim of this review to summarize the biophysical and tracer kinetic principles underlying this emerging imaging technique offering great potential for non-invasive characterization of tumour angiogenesis. In the first part, the relevant contrast mechanisms are presented that form the basis to relate signal variations measured by serial CT and MRI to local tissue concentrations of the administered CA. In the second part, the concepts most widely used for tracer kinetic modelling of concentration-time courses derived from measured DCE image data sets are described in a consistent and unified manner to highlight their particular structure and assumptions as well as the relationships among them. Finally, the concepts presented are exemplified by the analysis of representative DCE data as well as discussed with respect to present and future applications in cancer diagnosis and therapy. Depending on the specific protocol used for the acquisition of DCE image data and the particular model applied for tracer kinetic analysis of the derived concentration-time courses, different aspects of tumour angiogenesis can be quantified in terms of well-defined physiological tissue parameters. DCE imaging offers promising prospects for improved tumour diagnosis, individualization of cancer treatment as well as the evaluation of novel therapeutic concepts in preclinical and early-stage clinical trials. (orig.)

  12. Abdominal vascular and visceral parenchymal contrast enhancement in MDCT: Effects of injection duration

    Energy Technology Data Exchange (ETDEWEB)

    Tsuge, Yusuke, E-mail: tsugeu@cup.ocn.ne.jp [Department of Radiology, Kizawa Memorial Hospital, 590 Kobityo Shimokobi, Minokamo City, Gifu 505-8503 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University Hospital, Gifu (Japan); Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Goshima, Satoshi; Kondo, Hiroshi [Department of Radiology, Gifu University Hospital, Gifu (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka (Japan); Moriyama, Noriyuki [Research Center for Cancer Prevention and Screening, National Cancer Center Hospital, Tsukiji (Japan); Bae, Kyongtae T. [Radiology and Biomedical Engineering, University of Pittsburgh, Pittsburgh, PA (United States)

    2011-11-15

    Purpose: To evaluate and compare the effect of short and long injection durations on aortic, pancreatic and hepatic enhancement in abdominal MDCT. Methods and materials: Triphasic contrast-enhanced CT images (16-MDCT, 1.25-mm collimation, 5-mm thickness, 6.1-s acquisition time for each phase) were obtained with 2 mL/kg injection of 300 mgI/mL iodine contrast material in 116 patients. Patients were prospectively randomized into two groups: one receiving contrast medium for 25-s injection duration and the other for 35-s injection duration. In both groups, triphasic scans were initiated 5, 15, and 40 s after the completion of contrast injection for the first, second and third phases, respectively. CT values (HU) in the abdominal aorta, liver, spleen, pancreas, splenic and superior mesenteric arteries, and veins (splenic, superior mesenteric, portal, and hepatic) were measured. Quantitative and qualitative analysis for the degree of contrast enhancement between the two groups in various organs was compared at each scan phase. Results: The aortic and arterial enhancements in the first-phase scan were higher for the 25-s group than those of the 35-s group (P < .001). Hepatic enhancement was higher for the 35-s group in the first (P < .001) and second (P < .01) phases, but no difference in the third-phase. No difference was found between the groups for the pancreatic enhancement at any phases. Qualitative results were in good agreement with quantitative results. Conclusion: Contrast administration with shorter injection duration increased peak aortic and arterial enhancement and contributed to improvement in the quality of CT angiograms, but for the solid abdominal organs 35-s protocol is recommended.

  13. Dual-time point scanning of integrated FDG PET/CT for the evaluation of mediastinal and hilar lymph nodes in non-small cell lung cancer diagnosed as operable by contrast-enhanced CT

    International Nuclear Information System (INIS)

    Kasai, Takami; Motoori, Ken; Horikoshi, Takuro; Uchiyama, Katsuhiro; Yasufuku, Kazuhiro; Takiguchi, Yuichi; Takahashi, Fumiaki; Kuniyasu, Yoshio; Ito, Hisao

    2010-01-01

    Purpose: To evaluate whether dual-time point scanning with integrated fluorine-18 fluorodeoxyglucose ( 18 F-FDG) positron emission tomography and computed tomography (PET/CT) is useful for evaluation of mediastinal and hilar lymph nodes in non-small cell lung cancer diagnosed as operable by contrast-enhanced CT. Materials and methods: PET/CT data and pathological findings of 560 nodal stations in 129 patients with pathologically proven non-small cell lung cancer diagnosed as operable by contrast-enhanced CT were reviewed retrospectively. Standardized uptake values (SUVs) on early scans (SUVe) 1 h, and on delayed scans (SUVd) 2 h after FDG injection of each nodal station were measured. Retention index (RI) (%) was calculated by subtracting SUVe from SUVd and dividing by SUVe. Logistic regression analysis was performed with seven kinds of models, consisting of (1) SUVe, (2) SUVd, (3) RI, (4) SUVe and SUVd, (5) SUVe and RI, (6) SUVd and RI, and (7) SUVe, SUVd and RI. The seven derived models were compared by receiver-operating characteristic (ROC) analysis. k-Fold cross-validation was performed with k values of 5 and 10. p < 0.05 was considered statistically significant. Results: Model (1) including the term of SUVe showed the largest area under the ROC curve among the seven models. The cut-off probability of metastasis of 3.5% with SUVe of 2.5 revealed a sensitivity of 78% and a specificity of 81% on ROC analysis, and approximately 60% and 80% on k-fold cross-validation. Conclusion: Single scanning of PET/CT is sufficiently useful for evaluating mediastinal and hilar nodes for metastasis.

  14. Comparison of Allergic Adverse Effects and Contrast Enhancement Between Iodixanol and Iopromide

    International Nuclear Information System (INIS)

    Gharekhanloo, Farideh; Torabian, Saadat

    2012-01-01

    Iodinated X-ray contrast media are the most commonly used contrast agents in the world with an annual application of 40-50 million. New non-ionic contrast agents are subdivided into low osmolar agents such as iopromide and iso-osmolar agents such as iodixanol. Regarding different biochemical characteristics, these agents are different in the allergic reactions and contrast enhancement and final lesion conspicuity. This study was carried out to compare allergic adverse effects and contrast enhancement between iodixanol and iopromide. One-hundred and twenty patients who were referred for abdominal CT scan to Besat Hospital were included in this study. Patients were randomly divided into two groups (A and B). Group A received 100 cc iodixanol (300 mgI/mL) and group B received 100 cc iopromide (300 mgI/ml) by power injector. CT examination was performed using Helical CT Scanner (Somatom, Siemens, Germany). Sixty seconds after injection, images were obtained and enhancement of port, liver and aorta were determined. Allergic adverse effects were recorded one hour and up to one week after injection. Iodixanol produced a significantly greater enhancement of the hepatic, aorta and portal vein than iopromide (P < 0.01). Sixty seconds after injection, associated pain and heat sensation were less frequent in iodixanol in comparison with iopromide (P = 0.03). Immediate reactions such as nausea and vomiting were less frequent in iodixanol (P = 0.01). Late skin reactions such as rash was more frequent in iodixanol (P < 0.01). Iodixanol is safe and is better tolerated in the early phase of injection with better contrast enhancement and lesion conspicuity. Mild late skin rash is its disadvantage

  15. Contrast-enhanced CT in determining resectability in patients with pancreatic carcinoma: a meta-analysis of the positive predictive values of CT

    Energy Technology Data Exchange (ETDEWEB)

    Somers, Inne; Bipat, Shandra [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands)

    2017-08-15

    To obtain a summary positive predictive value (sPPV) of contrast-enhanced CT in determining resectability. The MEDLINE and EMBASE databases from JAN2005 to DEC2015 were searched and checked for inclusion criteria. Data on study design, patient characteristics, imaging techniques, image evaluation, reference standard, time interval between CT and reference standard, and data on resectability/unresectablity were extracted by two reviewers. We used a fixed-effects or random-effects approach to obtain sPPV for resectability. Several subgroups were defined: 1) bolus-triggering versus fixed-timing; 2) pancreatic and portal phases versus portal phase alone; 3) all criteria (liver metastases/lymphnode involvement/local advanced/vascular invasion) versus only vascular invasion as criteria for unresectability. Twenty-nine articles were included (2171 patients). Most studies were performed in multicentre settings, initiated by the department of radiology and retrospectively performed. The I{sup 2}-value was 68%, indicating heterogeneity of data. The sPPV was 81% (95%CI: 75-86%). False positives were mostly liver, peritoneal, or lymphnode metastases. Bolus-triggering had a slightly higher sPPV compared to fixed-timing, 87% (95%CI: 81-91%) versus 78% (95%CI: 66-86%) (p = 0.077). No differences were observed in other subgroups. This meta-analysis showed a sPPV of 81% for predicting resectability by CT, meaning that 19% of patients falsely undergo surgical exploration. (orig.)

  16. Contrast-enhanced ultrasound imaging of active bleeding associated with hepatic and splenic trauma.

    Science.gov (United States)

    Lv, F; Tang, J; Luo, Y; Li, Z; Meng, X; Zhu, Z; Li, T

    2011-10-01

    The aim of this study was to evaluate contrast-enhanced ultrasound (CEUS) imaging of active bleeding from hepatic and splenic trauma. Three hundred and ninety-two patients with liver or/and spleen trauma (179 liver and 217 spleen injuries), who underwent CEUS examinations following contrast-enhanced computed tomography (CT), were enrolled in this retrospective study over a period of >4 years. CEUS detected contrast medium extravasation or pooling in 16% (63/396) of liver or spleen lesions in 61 patients, which was confirmed by contrast-enhanced CT. Special attention was paid to observing the presence, location, and characteristics of the extravasated or pooled contrast medium. The CEUS detection rate for active bleeding was not different from that of contrast-enhanced CT (p=0.333). Information from surgery, minimally invasive treatment and conservative treatment was used as reference standard, and the sensitivities of the two techniques were not different (p=0.122). Of 63 lesions in 61 patients, CEUS showed that 74.6% (47/63) (21 liver lesions and 26 spleen lesions) presented contrast medium extravasation or pooling, both in the organ and out the capsule, in 14.3% (9/63) and only outside the capsule in 11.1% (7/63). CEUS imaging of active bleeding from hepatic and splenic trauma presented various characteristics, and the sizes and shapes of the active bleeding due to contrast medium extravasation or pooling were variable. CEUS can show the active bleeding associated with hepatic and splenic trauma with various imaging characteristics, thus making it possible to diagnose active bleeding using CEUS.

  17. Gadolinium as a CT contrast agent: an experimental study for the effects of injection parameters in the rabbit brain model

    International Nuclear Information System (INIS)

    Kim, Hyun Jin; Choi, Hye Young; Lee, Sun Wha; Hwang, Ji Young

    2005-01-01

    We wanted to investigate the use of gadolinium based contrast agent (Gd-DTPA) for computed tomography (CT), and we also wanted to assess the effects of valuable injection parameters on enhancement in an experimental rabbit brain model. In vitro, attenuation measurements of serial dilutions of Gd-DTPA and iopromide were compared. In five rabbits, single level dynamic gadolinium-enhanced brain CT studies were obtained using different injection parameters. A comparision CT scan after iopromide administration was performed. The time-attenuation curves of the brain vessel and parenchyma were obtained and the magnitude of enhancement (Hmax) and the time to peak enhancement (Tmax) were analyzed. In vitro, the attenuation coefficient of undiluted Gd-DTPA (2,578 HU) was higher than that of iopromide (1,761 HU) at equimolar concentrations. In 5 rabbits, the time-attenuation curve demonstrated a distinct pattern with peak enhancement only in the brain vessel, but not in the brain parenchyma. There was increasing linear relationship between the injection rate of Gd-DTPA and Hmax, and a declining linear relationship with Tmax. The higher the concentration of Gd-DTPA, the higher Hmax was, but no significant difference was found for the Tmax. Higher volumes of Gd-DTPA revealed a higher Hmax and a delayed Tmax. Enhancement of the brain parenchyma on gadolinium-enhanced CT is minimal, while enhancement of the brain vessels is distinctive. The most important factor affecting Hmax of the vessel is the concentration of the contrast medium and the most important factor affecting Tmax of the vessel is volume of the contrast medium. The gadolinium-based contrast agent may be an reasonable alternative contrast agent for brain CT, and especially in cerebral vessels, and it may also be advantageous for brain parenchyma of those patients with BBB dysfunction

  18. The use of 3D contrast-enhanced CT reconstructions to project images of vascular rings and coarctation of the aorta.

    Science.gov (United States)

    Di Sessa, Thomas G; Di Sessa, Peter; Gregory, Bill; Vranicar, Mark

    2009-01-01

    Aortic arch and pulmonary artery anomalies make up a group of vascular structures that have complex three-dimensional (3D) shapes. Tortuosity as well as hypoplasia or atresia of segments of the aortic arch or pulmonary artery makes the conventional two-dimensional (2D) imaging difficult. Nine patients with native coarctation or recoarctation and 4 patients with a vascular ring had a CT scan as a part of their clinical evaluation. There were 7 males. The mean age was 11.7 years. (range 19 days to 29 years) The mean weight was 22.7 kg (range 3.3-139.0 kg). The dicom data from contrast CT scans were converted by the Amira software package into a 3D image. The areas of interest were selected. The images were then projected in 3D on a standard video monitor and could be rotated 360 degrees in any dimension. Adequate CT scans and 3D reconstructions were obtained in 12 of 13 patients. There were 85-1,044 slices obtained in the adequate studies. We could not reconstruct a 3D image from a patient's CT scan that had only 22 slices. The anatomy defined by 3D was compared to 2D CT imaging and confirmed by cardiac catheterization or direct visualization in the operating room in the 12 patients with adequate 3D reconstructions. In 5 of 12 patients, 3D reconstructions provided valuable spatial information not observed in the conventional 2D scans. We believe that 3D reconstruction of contrast-enhanced CT scans of these complex structures provides additional valuable information that is helpful in the decision-making process.

  19. Contrast-enhanced magnetic resonance imaging for the detection of acute haemorrhagic necrotizing pancreatitis

    International Nuclear Information System (INIS)

    Piironen, A.; Kivisaari, R.; Pitkaeranta, P.; Poutanen, V.P.; Laippala, P.; Laurila, P.; Kivisaari, L.

    1997-01-01

    Eleven piglets with haemorrhagic necrotizing pancreatitis and nine piglets with oedematous pancreatitis were imaged using a multi-breath-hold TurboFLASH (TR 6.5 ms, TE 3 ms, TI 300 ms, flip angle 8 , three slices) pre-excited T1-weighted sequence with an IV bolus injection of gadopentetate dimeglumine (Gd-DTPA, 0.3 mmol/kg) as a contrast agent to show dynamic contrast enhancement of the pancreas by MRI. All piglets were imaged according to the same protocol before inducing the disease. Following the IV Gd-DTPA bolus, time-enhancement curve of the pancreas during haemorrhagic necrotizing pancreatitis was significantly lower than during oedematous pancreatitis. The enhancement curves for the healthy piglets and piglets with oedematous pancreatitis did not differ significantly. Each piglet served as its own control. Because the results of this initial study are similar to those obtained with contrast-enhanced CT, we conclude that our results may encourage further clinical trials, and contrast-enhanced dynamic MRI may be an alternative to the established method of CT for diagnosing acute haemorrhagic necrotizing pancreatitis. (orig.). With 3 figs

  20. CT findings of pancreatic carcinoma. Evaluation with the combined method of early enhancement CT and high dose enhancement CT

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Endo, Tokiko; Isomura, Takayuki; Ishigaki, Takeo; Ikeda, Mitsuru; Senda, Kouhei.

    1995-01-01

    Computed tomographic (CT) findings of pancreatic ductal adenocarcinoma were studied with the combined method of early enhancement CT and high dose enhancement CT in 72 carcinomas. Common Findings were change in pancreatic contour, abnormal attenuation in a tumor and dilatation of the main pancreatic duct. The incidence of abnormal attenuation and dilatation of the main pancreatic duct and bile duct was constant regardless of tumor size. The finding of hypoattenuation at early enhancement CT was most useful for demonstrating a carcinoma. However, this finding was negative in ten cases, five of which showed inhomogenous hyperattenuation at high dose enhancement CT. The detection of change in pancreatic contour and dilatation of the main pancreatic duct was most frequent at high dose enhancement CT. The finding of change in pancreatic contour and/or abnormal attenuation in a tumor could be detected in 47 cases at plain CT, 66 at early enhancement CT and 65 at high dose enhancement CT. Since the four cases in which neither finding was detected by any CT method showed dilatated main pancreatic duct, there was no case without abnormal CT findings. This combined CT method will be a reliable diagnostic technique in the imaging of pancreatic carcinoma. (author)

  1. Contrast-enhanced computed tomographic colonography in the follow-up of colorectal cancer patients: a feasibility study

    International Nuclear Information System (INIS)

    Laghi, Andrea; Iannaccone, Riccardo; Carbone, Iacopo; Piacentini, Francesca; Passariello, Roberto; Bria, Emilio; Trasatti, Luciana; Lauro, Salvatore; Vecchione, Aldo

    2003-01-01

    The aim of our study was to assess whether contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up program of colorectal cancer patients. Thirty-five patients, surgically treated for colorectal cancer, underwent a follow-up program that included physical examination, carcinoembryonic antigen serum assay, conventional colonoscopy, liver ultrasonography, and chest X-ray. For these patients, we added a yearly contrast-enhanced CT colonography. All CT examinations were performed with a high-resolution protocol using a multidetector spiral CT scanner (Siemens, Erlangen, Germany) prior to and after the administration of 130 ml of i.v. contrast material. Images were directly analyzed on a dedicated workstation by two radiologists to determine colonic evaluation, visualization of colonic anastomosis, presence of polyps, and extra-colonic findings. Colonic evaluation was judged as optimal in 91.7% of all colonic segments. All mechanical surgical anastomoses were visualized with CT colonography. There was no evidence of anastomotic recurrence. Seven polyps were detected in five different patients with CT colonography, with two false-positive and no false-negative examinations. Three liver metastases and two basal pulmonary nodules were also identified. Contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up of patients operated on for colorectal cancer. (orig.)

  2. Three-dimensional contrasted visualization of pancreas in rats using clinical MRI and CT scanners.

    Science.gov (United States)

    Yin, Ting; Coudyzer, Walter; Peeters, Ronald; Liu, Yewei; Cona, Marlein Miranda; Feng, Yuanbo; Xia, Qian; Yu, Jie; Jiang, Yansheng; Dymarkowski, Steven; Huang, Gang; Chen, Feng; Oyen, Raymond; Ni, Yicheng

    2015-01-01

    The purpose of this work was to visualize the pancreas in post-mortem rats with local contrast medium infusion by three-dimensional (3D) magnetic resonance imaging (MRI) and computed tomography (CT) using clinical imagers. A total of 16 Sprague Dawley rats of about 300 g were used for the pancreas visualization. Following the baseline imaging, a mixed contrast medium dye called GadoIodo-EB containing optimized concentrations of Gd-DOTA, iomeprol and Evens blue was infused into the distally obstructed common bile duct (CBD) for post-contrast imaging with 3.0 T MRI and 128-slice CT scanners. Images were post-processed with the MeVisLab software package. MRI findings were co-registered with CT scans and validated with histomorphology, with relative contrast ratios quantified. Without contrast enhancement, the pancreas was indiscernible. After infusion of GadoIodo-EB solution, only the pancreatic region became outstandingly visible, as shown by 3D rendering MRI and CT and proven by colored dissection and histological examinations. The measured volume of the pancreas averaged 1.12 ± 0.04 cm(3) after standardization. Relative contrast ratios were 93.28 ± 34.61% and 26.45 ± 5.29% for MRI and CT respectively. We have developed a multifunctional contrast medium dye to help clearly visualize and delineate rat pancreas in situ using clinical MRI and CT scanners. The topographic landmarks thus created with 3D demonstration may help to provide guidelines for the next in vivo pancreatic MRI research in rodents. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Local ablation therapy with contrast-enhanced ultrasonography for hepatocellular carcinoma: a practical review

    Directory of Open Access Journals (Sweden)

    Tae Kyoung Kim

    2015-10-01

    Full Text Available A successful program for local ablation therapy for hepatocellular carcinoma (HCC requires extensive imaging support for diagnosis and localization of HCC, imaging guidance for the ablation procedures, and post-treatment monitoring. Contrast-enhanced ultrasonography (CEUS has several advantages over computed tomography/magnetic resonance imaging (CT/MRI, including real-time imaging capability, sensitive detection of arterial-phase hypervascularity and washout, no renal excretion, no ionizing radiation, repeatability, excellent patient compliance, and relatively low cost. CEUS is useful for image guidance for isoechoic lesions. While contrast-enhanced CT/MRI is the standard method for the diagnosis of HCC and post-ablation monitoring, CEUS is useful when CT/MRI findings are indeterminate or CT/MRI is contraindicated. This article provides a practical review of the role of CEUS in imaging algorithms for pre- and post-ablation therapy for HCC.

  4. Dual-time point scanning of integrated FDG PET/CT for the evaluation of mediastinal and hilar lymph nodes in non-small cell lung cancer diagnosed as operable by contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Kasai, Takami, E-mail: takaby@hotmail.co [Department of Radiology, Chiba University Hospital, 1-8-1 Inohana, Chuo-ku, Chiba City, Chiba-ken 260-8677 (Japan); Motoori, Ken, E-mail: motoorik@faculty.chiba-u.j [Department of Radiology, Chiba University Hospital, 1-8-1 Inohana, Chuo-ku, Chiba City, Chiba-ken 260-8677 (Japan); Horikoshi, Takuro, E-mail: taku_steelfish@yahoo.co.j [Department of Radiology, Chiba University Hospital, 1-8-1 Inohana, Chuo-ku, Chiba City, Chiba-ken 260-8677 (Japan); Uchiyama, Katsuhiro, E-mail: ka-uchiyama@nifty.co [Diagnostic PET Imaging Center, Department of Radiology, Sannoh Medical Center, 166-2 Sannohcho, Inage-ku, Chiba City, Chiba-ken 263-0002 (Japan); Yasufuku, Kazuhiro, E-mail: kyasufuku@faculty.chiba-u.j [Department of Thoracic Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba City, Chiba-ken 260-8670 (Japan); Takiguchi, Yuichi, E-mail: takiguchi@faculty.chiba-u.j [Department of Respirology, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba City, Chiba-ken 260-8670 (Japan); Takahashi, Fumiaki, E-mail: takahashifu@pharm.kitasato-u.ac.j [Division of Biostatistics, Graduate School of Pharmaceutical Sciences, Kitasato University, 5-9-1 Shirokane, Minato-ku, Tokyo 108-8641 (Japan); Kuniyasu, Yoshio, E-mail: kuniyasu@ace.ocn.ne.j [Diagnostic PET Imaging Center, Department of Radiology, Sannoh Medical Center, 166-2 Sannohcho, Inage-ku, Chiba City, Chiba-ken 263-0002 (Japan); Ito, Hisao, E-mail: hisao@faculty.chiba-u.j [Department of Radiology, Chiba University Hospital, 1-8-1 Inohana, Chuo-ku, Chiba City, Chiba-ken 260-8677 (Japan)

    2010-08-15

    Purpose: To evaluate whether dual-time point scanning with integrated fluorine-18 fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography and computed tomography (PET/CT) is useful for evaluation of mediastinal and hilar lymph nodes in non-small cell lung cancer diagnosed as operable by contrast-enhanced CT. Materials and methods: PET/CT data and pathological findings of 560 nodal stations in 129 patients with pathologically proven non-small cell lung cancer diagnosed as operable by contrast-enhanced CT were reviewed retrospectively. Standardized uptake values (SUVs) on early scans (SUVe) 1 h, and on delayed scans (SUVd) 2 h after FDG injection of each nodal station were measured. Retention index (RI) (%) was calculated by subtracting SUVe from SUVd and dividing by SUVe. Logistic regression analysis was performed with seven kinds of models, consisting of (1) SUVe, (2) SUVd, (3) RI, (4) SUVe and SUVd, (5) SUVe and RI, (6) SUVd and RI, and (7) SUVe, SUVd and RI. The seven derived models were compared by receiver-operating characteristic (ROC) analysis. k-Fold cross-validation was performed with k values of 5 and 10. p < 0.05 was considered statistically significant. Results: Model (1) including the term of SUVe showed the largest area under the ROC curve among the seven models. The cut-off probability of metastasis of 3.5% with SUVe of 2.5 revealed a sensitivity of 78% and a specificity of 81% on ROC analysis, and approximately 60% and 80% on k-fold cross-validation. Conclusion: Single scanning of PET/CT is sufficiently useful for evaluating mediastinal and hilar nodes for metastasis.

  5. Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response

    Energy Technology Data Exchange (ETDEWEB)

    Eisa, Fabian [University of Erlangen-Nuremberg, Institute of Medical Physics, Erlangen (Germany); University of Erlangen-Nuremberg, Graduate School in Advanced Optical Technologies (SAOT), Erlangen (Germany); Brauweiler, Robert; Hupfer, Martin; Nowak, Tristan; Kalender, Willi A. [University of Erlangen-Nuremberg, Institute of Medical Physics, Erlangen (Germany); Lotz, Laura; Hoffmann, Inge; Dittrich, Ralf; Beckmann, Matthias W. [University of Erlangen-Nuremberg, OB/GYN, University Hospital Erlangen, Erlangen (Germany); Wachter, David [University Hospital Erlangen, Institute of Pathology, Erlangen (Germany); Jost, Gregor; Pietsch, Hubertus [Bayer Pharma AG, Berlin (Germany)

    2012-04-15

    To evaluate the potential of in vivo dynamic contrast-enhanced micro-computed tomography (DCE micro-CT) for the assessment of antiangiogenic drug therapy response of mice with mammary carcinoma. 20 female mice with implanted MCF7 tumours were split into control group and therapy group treated with a known effective antiangiogenic drug. All mice underwent DCE micro-CT for the 3D analysis of functional parameters (relative blood volume [rBV], vascular permeability [K], area under the time-enhancement curve [AUC]) and morphology. All parameters were determined for total, peripheral and central tumour volumes of interest (VOIs). Immunohistochemistry was performed to characterise tumour vascularisation. 3D dose distributions were determined. The mean AUCs were significantly lower in therapy with P values of 0.012, 0.007 and 0.023 for total, peripheral and central tumour VOIs. K and rBV showed significant differences for the peripheral (P{sub per}{sup K} = 0.032, P{sub per}{sup rBV} = 0.029), but not for the total and central tumour VOIs (P{sub total}{sup K} = 0.108, P{sub central}{sup K} = 0.246, P{sub total}{sup rBV} = 0.093, P{sub central}{sup rBV} = 0.136). Mean tumour volume was significantly smaller in therapy (P{sub in} {sub vivo} = 0.001, P{sub ex} {sub vivo} = 0.005). Histology revealed greater vascularisation in the controls and central tumour necrosis. Doses ranged from 150 to 300 mGy. This study indicates the great potential of DCE micro-CT for early in vivo assessment of antiangiogenic drug therapy response. (orig.)

  6. Enhancement pattern of small hepatic hemangioma: findings on multiphase spiral CT and dynamic MRI

    International Nuclear Information System (INIS)

    Choi, Byung In; Lee, Seung Koo; Kim, Myeong Jin; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To compare the enhancement characteristics of small hemangiomas seen on multiphase spiral CT and dynamic MR imaging. Thirteen patients with 20 hepatic hemangiomas less than 25mm in diameter underwent both multiphase spiral CT and dynamic MR imaging. All lesions were assigned to one of three classified into 3 categories according to the enhancement pattern seen on multiphase spiral CT : typical delayed pooling, atypical early enhancement, or continuous low attenuation. The enhancement patterns seen on spiral CT and on dynamic MRI were correlated. On CT scans, ten lesions (50%) showed delayed pooling. Six (30%) showed early arterial enhancement and four (20%) showed continuous low attenuation. On delayed-phase MRI, all lesions showed delayed high signal intensity compared to adjacent liver parenchyma. Four of six lesions with early enhancement on CT showed peripheral globular enhancement on early arterial-phase MRI. On multiphase spiral CT scans, small hemangiomas can show variable atypical enhancement features. In this situation, contrast-enhanced dynamic MRI is helpful for the diagnosis of hemangiomas

  7. Contrast-enhanced ultrasound features of histologically proven focal nodular hyperplasia: diagnostic performance compared with contrast-enhanced CT

    International Nuclear Information System (INIS)

    Wang, Wei; Chen, Li-Da; Liu, Guang-Jian; Xu, Zuo-Feng; Xie, Xiao-Yan; Wang, Yan; Zhou, Lu-Yao; Lu, Ming-De; Shen, Shun-Li

    2013-01-01

    To investigate and compare contrast-enhanced ultrasound (CEUS) in the characterisation of histologically proven focal nodular hyperplasia (FNH) with contrast-enhanced computed tomography (CECT). CEUS was performed in 85 patients with 85 histologically proven FNHs. Enhancement, centrifugal filling, spoke-wheel arteries, feeding artery and central scarring were reviewed and correlated with lesion size or liver background. Independent factors for predicting FNH from other focal liver lesions (FLLs) were evaluated. Forty-seven FLLs with CECT were randomly selected for comparison of diagnostic performance with CEUS. Centrifugal filling was more common (P = 0.002) and the significant predictor (P = 0.003) in FNHs ≤3 cm. Lesion size or liver background has no significant influence on the detection rate of the spoke-wheel arteries and feeding artery (P > 0.05). Central scarring was found in 42.6 % of FNHs ≥3 cm (P = 0.000). The area under the ROC curve, sensitivity and specificity showed no significant differences between CEUS and CECT (P > 0.05), except that the sensitivity of CEUS was better for reader 1 (P = 0.041). CEUS is valuable in characterising centrifugal filling signs or spoke wheels in small FNHs and should be employed as the first-line imaging technique for diagnosis of FNH. (orig.)

  8. An albumin-based gold nanocomposites as potential dual mode CT/MRI contrast agent

    Science.gov (United States)

    Zhao, Wenjing; Chen, Lina; Wang, Zhiming; Huang, Yuankui; Jia, Nengqin

    2018-02-01

    In pursuit of the biological detection applications, recent years have witnessed the prosperity of novel multi-modal nanoprobes. In this study, biocompatible bovine serum albumin (BSA)-coated gold nanoparticles (Au NPs) containing Gd (III) as the contrast agent for both X-ray CT and T1-weighted MR imaging is reported. Firstly, the Au NPs with BSA coating (Au@BSA) was prepared through a moderate one-pot reduction route in the presence of hydrazine hydrate as reducer. Sequentially, the BSA coating enables modification of diethylenetriaminepentaacetic acid (DTPA) as well as targeting reagent hyaluronic acid (HA), and further chelation of Gd (III) ions led to the formation of biomimetic nanoagent HA-targeted Gd-Au NPs (HA-targeted Au@BSA-Gd-DTPA). Several techniques were used to thoroughly characterize the formed HA-targeted Gd-Au NPs. As expected, the as-prepared nanoagent with mean diameter of 13.82 nm exhibits not only good colloid stablility and water dispersibility, but also satisfying low cytotoxicity and hemocompatibility in the tested concentration range. Additionally, for the CT phantoms, the obtained nanocomplex shows an improved contrast in CT scanning than that of Au@BSA as well as small molecule iodine-based CT contrast agents such as iopromide. Meanwhile, for the T1-weighted MRI images, there is a linear increase of contrast with concentration of Gd for the two cases of HA-targeted Gd-Au NPs and Magnevist. Strikingly, the nanoagent we explored displays a relatively higher r1 relaxivity than that of commercial MR contrast agents. Therefore, this newly constructed nanoagent could be used as contrast agents for synergistically enhanced X-ray CT and MR phantoms, holding promising potential for future biomedical applications.

  9. Detection of underlying malignancy in patients with paraneoplastic neurological syndromes: comparison of {sup 18}F-FDG PET/CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, N.; Schmid-Tannwald, C.; Meinel, F.G.; Reiser, M.F.; Rist, C. [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Rominger, A. [Ludwig-Maximilians-University Hospital Munich, Department of Nuclear Medicine, Munich (Germany); Schmidt, C. [Ludwig-Maximilians-University Hospital Munich, Department of Neurology, Munich (Germany); Morelli, J.N. [Texas A and M Health Sciences Center, Department of Radiology, Temple, TX (United States)

    2013-07-15

    To determine the value of combined {sup 18}F-FDG PET/CT with diagnostic contrast-enhanced CT (CECT) in detecting primary malignancies and metastases in patients with paraneoplastic neurological syndromes (PNS) and to compare this with CECT alone. PET/CT scans from 66 patients with PNS were retrospectively evaluated. Two blinded readers initially reviewed the CECT portion of each PET/CT scan. In a second session 3 months later, the readers analysed the combined PET/CT scans. Findings on each study were assessed using a four-point-scale (1 normal/benign; 2 inconclusive, further diagnostic work-up may be necessary; 3 malignant; 4 inflammatory). Sensitivity and specificity for malignant findings were calculated for PET/CT and CECT. Interreader agreement was determined by calculating Cohen's kappa. Pooled data from clinical follow-up (including histopathology and follow-up imaging, median follow-up 20.0 months) served as the reference gold standard. Both readers classified 12 findings in ten patients (15 %) as malignant on the PET/CT scans (two patients had two primary tumours). One such imaging finding (suspected thymic cancer) was false-positive (i.e. benign histology). The most common tumours were bronchial carcinoma (n = 3), lymph node metastases of gynaecological tumours (n = 3) and tonsillar carcinoma (n = 2). Three of 12 findings (25 %) were not detected by CECT alone (cervical carcinoma, lymph node metastasis and tonsillar carcinoma). In a per-patient analysis, sensitivity and specificity for malignant findings were 100 % and 90 % for PET/CT and 78 % and 88 % for CECT. In 24 % (reader 1) and 21 % (reader 2) of the patients, the PET/CT findings were inconclusive. Of these findings, 57 % (reader 1) and 56 % (reader 2) were only diagnosed with PET (e.g. focal FDG uptake of the thyroid, gastrointestinal tract and ovaries). On follow-up, none of these findings corresponded to malignancy. Overall agreement between the two readers was excellent with a Cohen

  10. Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Mo, E-mail: Sunmo.Kim@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9 (Canada); Haider, Masoom A. [Department of Medical Imaging, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5, Canada and Department of Medical Imaging, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Yeung, Ivan W. T. [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9 (Canada); Department of Medical Physics, Stronach Regional Cancer Centre, Southlake Regional Health Centre, Newmarket, Ontario L3Y 2P9 (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada)

    2016-01-15

    Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the

  11. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-02-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author).

  12. Ct enterography/ct abdomen and pelvis using neutral oral contrast. a new combination of natural products

    International Nuclear Information System (INIS)

    Aslam, M.O.

    2014-01-01

    Our purpose was to assess the performance of a new combination of neutral oral contrast for CT abdomen and CT Enterography in comparison with commercially available neutral oral contrast VoLumen. Seventy three consecutive patients were given sorbitol/CMC (Carboxy Methyl Cellulose) solution or VoLumen as oral contrast agent for abdominal computed tomography (CT) scan. 23 patients were male and 37 females. Age range was between 16 and 67 years. Since the use of CT scan for abdominal pathologies, there was need to separate bowel loops to localize the pathology. Three types of oral contrast can be used in CT-Scan abdomen; Positive, Neutral and negative. The above used contrasts are Neutral contrast these refers to agents that have an attenuation value similar to that of water (0-30 H).Our results show this new combination of Cc and Sorbitol to be equally good as VoLumen, for luminal distension and mural details, in duodenum and jejunum. While better than VoLumen for Ileal distension. (author)

  13. Adverse drug reactions to CT contrast media in south Korea: Incidence and risk factors

    International Nuclear Information System (INIS)

    Bae, Kyung Soo; Jeon, Kyung Nyeo; Moon, Jin Il; Choi, Bo Hwa; Baek, Hye Jin; Cho, Soo Buem; Lee, Sang Min; Ha, Ji Young; Choi, Dae Seob; Cho, Jae Min; Na, Jae Beom

    2016-01-01

    To evaluate the incidence, severity, and risk factors of adverse drug reactions (ADR) to intravenous administration of nonionic iodinated contrast media in computed tomography (CT), and to determine the recurrence rate after premedication in patients with a previous history of ADR. We prospectively recorded all ADR to intravenous CT contrast media in 32313 consecutive outpatients (54572 cases) who underwent contrast enhanced CT examinations. Clinical report forms and electronic medical records were reviewed to search for the incidence of ADR, treatment, and clinical outcome of patients. The risk factors of ADR to CT contrast media (age, sex, history of previous ADR, season) were evaluated using statistical analysis. Of the 54572 cases, a total of 191 (0.35%) had adverse reactions. Of the 191 cases, 157 (82%) were categorized as mild reactions, 29 (15%) were moderate, and 5 (3%) were severe. A total of 165 (86.4%) cases had acute adverse reactions (which occurred within 1 hour after administration), while 26 (13.6%) had delayed adverse reactions (occurred 1 hour after the administration). The rate of ADR was significantly higher in females [relative risk (RR) = 2.05, 95% confidence interval (CI) 1.53-2.75], patients under the age of 60 years (RR = 1.45, 95% CI 1.07-1.98), patients with a history of previous ADR (RR = 6.51, 95% CI 3.13-13.57), and in the spring season (RR = 1.44, 95% CI 1.07-1.95). The recurrence rate after premedication in patients with previous ADR to CT contrast media was 3.2% (8/247). No deaths occurred that were attributed to the contrast media. The incidence of ADR to nonionic CT contrast media was 0.35%; most of which were mild reactions. Risk factors for ADR included female gender, an age of under 60 years, a history of previous ADR, and spring season

  14. Adverse drug reactions to CT contrast media in south Korea: Incidence and risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Kyung Soo; Jeon, Kyung Nyeo; Moon, Jin Il; Choi, Bo Hwa; Baek, Hye Jin; Cho, Soo Buem [Dept. of Radiology, Gyeongsang National University Changwon Hospital, Gyeongsang National University School of Medicine, Changwon (Korea, Republic of); Lee, Sang Min; Ha, Ji Young; Choi, Dae Seob; Cho, Jae Min; Na, Jae Beom [Dept. of Radiology, Gyeongsang National University Hospital, Gyeongsang National University School of Medicine, Jinju (Korea, Republic of)

    2016-07-15

    To evaluate the incidence, severity, and risk factors of adverse drug reactions (ADR) to intravenous administration of nonionic iodinated contrast media in computed tomography (CT), and to determine the recurrence rate after premedication in patients with a previous history of ADR. We prospectively recorded all ADR to intravenous CT contrast media in 32313 consecutive outpatients (54572 cases) who underwent contrast enhanced CT examinations. Clinical report forms and electronic medical records were reviewed to search for the incidence of ADR, treatment, and clinical outcome of patients. The risk factors of ADR to CT contrast media (age, sex, history of previous ADR, season) were evaluated using statistical analysis. Of the 54572 cases, a total of 191 (0.35%) had adverse reactions. Of the 191 cases, 157 (82%) were categorized as mild reactions, 29 (15%) were moderate, and 5 (3%) were severe. A total of 165 (86.4%) cases had acute adverse reactions (which occurred within 1 hour after administration), while 26 (13.6%) had delayed adverse reactions (occurred 1 hour after the administration). The rate of ADR was significantly higher in females [relative risk (RR) = 2.05, 95% confidence interval (CI) 1.53-2.75], patients under the age of 60 years (RR = 1.45, 95% CI 1.07-1.98), patients with a history of previous ADR (RR = 6.51, 95% CI 3.13-13.57), and in the spring season (RR = 1.44, 95% CI 1.07-1.95). The recurrence rate after premedication in patients with previous ADR to CT contrast media was 3.2% (8/247). No deaths occurred that were attributed to the contrast media. The incidence of ADR to nonionic CT contrast media was 0.35%; most of which were mild reactions. Risk factors for ADR included female gender, an age of under 60 years, a history of previous ADR, and spring season.

  15. Multi-detector row helical CT of the liver. Quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT. A prospective randomized study

    International Nuclear Information System (INIS)

    Tsurusaki, Masakatsu; Sugimoto, Koji; Fujii, Masahiko; Sugimura, Kazuro

    2004-01-01

    The purpose of this study was to assess the quantitative effects of contrast material concentration on hepatic parenchymal and vascular enhancement in multiphasic computed tomography (CT), using multi-detector row helical CT. We designed a prospective randomized study to test two different concentrations of contrast material on five phasic scans of the liver. One hundred patients were randomly assigned to two groups: an iodine concentration of 300 mg/mL in group A and 370 mg/mL in group B. All patients received a fixed volume of 100 mL at a 4 mL/sec injection rate. Enhancement values for the hepatic parenchyma and aorta at three levels (upper, middle, and lower level of the liver), and values for portal and hepatic veins were statistically compared between the two groups. Hepatic parenchymal enhancement values at all levels of the liver in portal phase (PP) and equilibrium phase (EP) were significantly higher in group B than in group A (p<0.01). Aortic enhancement values at two levels of the liver (middle and lower) in early hepatic arterial phase (EAP) were significantly higher in group B than in group A (p<0.05), however, there was no significant difference between groups A and B in aortic enhancement during the delayed hepatic arterial phase (DAP). Portal and hepatic venous enhancement values in PP and EP were significantly higher in group B than in group A (p<0.01). On multiphasic dynamic CT, the use of a higher iodine concentration of contrast material results in higher hepatic parenchymal enhancement and aortic enhancement, as well as higher portal and hepatic venous enhancement. (author)

  16. Value of contrast enhancement with Gd-DTPA in MRI of brain tumors. A comparison with X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Tsuji, Takehisa; Kishikawa, Takashi; Ikezaki, Kiyonobu; Fujii, Kiyotaka; Matsumoto, Shunichi; Koga, Toshihiko.

    1987-12-01

    Value of administration of Gadolinium-DTPA dimeglumine (Gd-DTPA), a magnetic resonance contrast agent, in MRI was evaluated in 17 patients of primary brain tumors and 3 metastatic tumors with known pathology, comparing with CT findings. MRI was performed with T/sub 1/-weighted spin echo pulse sequence (SE 50030) prior to and following the intravenous injection of 0.10 mmolkg Gd-DTPA. All, but one pituitary microadenoma, the tumors including meningiomas, pituitary adenomas, gliomas, intraventricular craniopharyngioma and acoustic neurinoma and metastatic lung adenocarcinomas, were enhanced by Gd-DTPA on T/sub 1/-weighted images. Good definition of the exact boundaries and extent of the mass to the surrounding structures were obtained in all these cases. Especially, the invasion of meningioma to the dura mater or to the venous sinus, and that of cerebellopontine angle tumor to the internal auditory meatus or to the jugular foramen, were better delineated on MRI as compared with CT. The anatomical relationship to the surrounding structures in the sellar or parasellar tumors were also clearly demonstrated on MRI. Thus, MRI with Gd-DTPA administration was useful for the preoperative assessment and Gd-DTPA appears to be a safe contrast agent for MRI since there were no significant untoward reactions in our series.

  17. In-line phase contrast micro-CT reconstruction for biomedical specimens.

    Science.gov (United States)

    Fu, Jian; Tan, Renbo

    2014-01-01

    X-ray phase contrast micro computed tomography (micro-CT) can non-destructively provide the internal structure information of soft tissues and low atomic number materials. It has become an invaluable analysis tool for biomedical specimens. Here an in-line phase contrast micro-CT reconstruction technique is reported, which consists of a projection extraction method and the conventional filter back-projection (FBP) reconstruction algorithm. The projection extraction is implemented by applying the Fourier transform to the forward projections of in-line phase contrast micro-CT. This work comprises a numerical study of the method and its experimental verification using a biomedical specimen dataset measured at an X-ray tube source micro-CT setup. The numerical and experimental results demonstrate that the presented technique can improve the imaging contrast of biomedical specimens. It will be of interest for a wide range of in-line phase contrast micro-CT applications in medicine and biology.

  18. Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease

    International Nuclear Information System (INIS)

    Helmberger, T.; Gregor, M.; Holzknecht, N.; Scheidler, J.; Reiser, M.; Rau, H.

    2000-01-01

    Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 hemangioma, 1 regenerative nodule) all modalities failed, causing unnecessary surgery in one patient. Discussion: In this problem-oriented scenario unenhanced and SPIO-enhanced MRI proved to be superior to CT regarding diagnostic efficacy. The cost-benefit resulted mainly due to preserving patients from unnecessary surgical procedures. (orig./AJ) [de

  19. CT manifestations of liver abscess

    International Nuclear Information System (INIS)

    Yan Jianfeng; Peng Yongjun

    2006-01-01

    Objective: To study CT findings of hepatic abscess. Methods: CT findings and clinical materials of 38 patients with liver abscess verified by aspiration were retrospectively viewed. All patients were examined by non-enhanced and contrast enhanced CT. Results: In 25 cases, inhomogeneous hypodense lesions with unclear demarcation were found on non-enhanced CT. On contrast enhanced CT scan, target or cluster enhancement was found Additionally, air was found within some lesions. In the rest 13 cases with early stage liver abscess, no typical sign was found on non-enhanced CT, while rosette sign and continued enhancement sign were demonstrated after the contrast agent was given. Conclusion: Various CT findings are found in different stages of liver abscess. The diagnosis and differential diagnosis should be based on CT manifestations and clinical history as well. (authors)

  20. Contrast-enhanced multidetector computerized tomography for odontogenic cysts and cystic-appearing tumors of the jaws: is it useful?

    Science.gov (United States)

    Kakimoto, Naoya; Chindasombatjaroen, Jira; Tomita, Seiki; Shimamoto, Hiroaki; Uchiyama, Yuka; Hasegawa, Yoko; Kishino, Mitsunobu; Murakami, Shumei; Furukawa, Souhei

    2013-01-01

    The purpose of this study was to investigate the usefulness of computerized tomography (CT), particularly contrast-enhanced CT, in differentiation of jaw cysts and cystic-appearing tumors. We retrospectively analyzed contrast-enhanced CT images of 90 patients with odontogenic jaw cysts or cystic-appearing tumors. The lesion size and CT values were measured and the short axis to long axis (S/L) ratio, contrast enhancement (CE) ratio, and standard deviation ratio were calculated. The lesion size and the S/L ratio of keratocystic odontogenic tumors were significantly different from those of radicular cysts and follicular cysts. There were no significant differences in the CE ratio among the lesions. Multidetector CT provided diagnostic information about the size of odontogenic cysts and cystic-appearing tumors of the jaws that was related to the lesion type, but showed no relation between CE ratio and the type of these lesions. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Non-small cell lung cancer: evaluation of the relationship between fibrosis and washout feature at dynamic contrast enhanced CT

    International Nuclear Information System (INIS)

    Ye Xiaodan; Yuan Zheng; Ye Jianding; Li Huimin; Zhu Yuzhao; Zhang Shunmin; Liu Shiyuan; Xiao Xiangsheng

    2010-01-01

    Objective: To correlate dynamic parameters at contrast enhanced CT and interstitial fibrosis grade of' non-small cell lung cancer (NSCLC). Methods: Twenty-nine patients with NSCLC were evaluated by multi-slice CT. Images were obtained before and at 20, 30, 45, 60, 75, 90, 120, 180, 300, 540, 720, 900 and 1200 s after the injection of contrast media, which was administered at a rate of 4 ml/s for a total of 420 mg I/kg body weight. Washout parameters were calculated. Lung cancer specimens were stained with hematoxylin-eosin stain and collagen and elastic double stain. Spearman test was made to analyze correlation between dynamic parameters and interstitial fibrosis grade of tumor. Results: Twenty- nine NSCLC demonstrated washout at 20 min 12.1 (0.32-58.0) HU, washout ratio at 20 minutes 15.3% (0.3%-39.2%), slope of washout at 20 minutes 0.0152%/s (0.0007%/s-0.0561%/s). Interstitial fibrosis of 29 lesions was graded as grade Ⅰ (10), grade Ⅱ (14) and grade Ⅲ (5). There were significant correlation between washout at 20 min (r=-0.402, P<0.05), washout ratio at 20 min (r= -0.372, P<0.05), slope of washout ratio (r=-0.459, P<0.05) and interstitial fibrosis grade in tumors. Conclusion: NSCLC washout features at dynamic multi-detector CT correlates with interstitial fibrosis in the tumor. (authors)

  2. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    International Nuclear Information System (INIS)

    Moselewski, Fabian; Ferencik, Maros; Achenbach, Stephan; Abbara, Suhny; Cury, Ricardo C.; Booth, Sarah L.; Jang, Ik-Kyung; Brady, Thomas J.; Hoffmann, Udo

    2006-01-01

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT

  3. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moselewski, Fabian [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Ferencik, Maros [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Achenbach, Stephan [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Internal Medicine II (Cardiology), University of Erlangen (Germany); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Booth, Sarah L. [Jean Mayer USDA Human Nutrition Research Center on Aging, 711 Washington St., Boston, MA 02114 (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)]. E-mail: uhoffman@partners.org

    2006-03-15

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM] at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 {+-} 68.7 HU versus 295 {+-} 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

  4. Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT.

    Science.gov (United States)

    Ananthakrishnan, Lakshmi; Rajiah, Prabhakar; Ahn, Richard; Rassouli, Negin; Xi, Yin; Soesbe, Todd C; Lewis, Matthew A; Lenkinski, Robert E; Leyendecker, John R; Abbara, Suhny

    2017-03-01

    To assess virtual non-contrast (VNC) images obtained on a detection-based spectral detector CT scanner and determine how attenuation on VNC images derived from various phases of enhanced CT compare to those obtained from true unenhanced images. In this HIPAA compliant, IRB approved prospective multi-institutional study, 46 patients underwent pre- and post-contrast imaging on a prototype dual-layer spectral detector CT between October 2013 and November 2015, yielding 84 unenhanced and VNC pairs (25 arterial, 39 portal venous/nephrographic, 20 urographic). Mean attenuation was measured by one of three readers in the liver, spleen, kidneys, psoas muscle, abdominal aorta, and subcutaneous fat. Equivalence testing was used to determine if the mean difference between unenhanced and VNC attenuation was less than 5, 10, or 15 HU. VNC image quality was assessed on a 5 point scale. Mean difference between unenhanced and VNC attenuation was VNC attenuation were equivalent in all tissues except fat using a threshold of VNC overestimated the HU relative to unenhanced images. VNC image quality was rated as excellent or good in 84% of arterial phase and 85% of nephrographic phase cases, but only 40% of urographic phase. VNC images derived from novel dual layer spectral detector CT demonstrate attenuation values similar to unenhanced images in all tissues evaluated except for subcutaneous fat. Further study is needed to determine if attenuation thresholds currently used clinically for common pathology should be adjusted, particularly for lesions containing fat.

  5. The characterization of small hypoattenuating renal masses on contrast-enhanced CT☆

    Science.gov (United States)

    Patel, Neesha S.; Poder, Liina; Wang, Zhen J.; Yeh, Benjamin M.; Qayyum, Aliya; Jin, Hua; Coakley, Fergus V.

    2011-01-01

    Purpose To determine if small hypoattenuating renal masses can be characterized as simple cysts or renal cell carcinomas on contrast-enhanced computed tomography (CT). Materials and methods We retrospectively identified 20 small (≤1.5 cm) hypoattenuating renal masses seen on contrast enhanced CT, consisting of 14 simple cysts and six renal cell carcinomas. Three independent readers recorded subjective visual impression (five-point scale from 1=definitely fluid to 5=definitely solid), CT attenuation, border (well circumscribed or ill defined), and shape (ovoid or irregular) for each lesion. Results The overall area under the receiver operator characteristic curves for subjective visual impression, CT attenuation, border, and shape were 0.97, 0.82, 0.59, and 0.55, respectively. Using dichotomized ratings (1–2=cyst and 3–5=carcinoma), subjective impression had a sensitivity and specificity of 100% and 79–100%, respectively, for the diagnosis of renal cell carcinoma. Using a threshold of 50 Hounsfield Units (HU) or more, CT attenuation had a sensitivity and specificity of 100% and 43–64%, respectively. Conclusion Small hypoattenuating renal masses can be characterized with reasonable accuracy by subjective impression and CT attenuation; lesions that appear solid on visual inspection or have an attenuation value of 50 HU or more are likely to be renal cell carcinoma. © 2009 Elsevier Inc. All rights reserved. PMID:19559352

  6. Contrast-enhanced ultrasound for extrahepatic lesions: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Thorelius, Lars E-mail: lars@thorelius.com

    2004-06-01

    Ultrasound imaging (US) is a convenient, inexpensive and non-invasive investigation. Its use is limited by low sensitivity in the detection of a number of parenchymal lesions, especially those produced by trauma, such as infarctions. Contrast enhancement with SonoVue{sup [reg]} improves the sensitivity of ultrasound in the detection and characterization of focal liver lesions to such an extent, that it may replace computed tomography (CT) and magnetic resonance imaging (MRI). Preliminary experience suggests that SonoVue-enhanced sonography may be useful in the detection of lesions in which blood flow is severely reduced as compared to surrounding parenchyma, such as infarctions, lacerations, hematomas, necrotic tissue and non-vascular cysts, especially in the spleen, kidney and pancreas. This technique can also rule out occlusion of the superior mesenteric, splenic and portal veins, and dilation of the biliary tree. Clinical trials comparing contrast-enhanced sonography with contrast-enhanced computed tomography are warranted to establish the role of this inexpensive and non-invasive technique in the routine work-up of patients with abdominal trauma or presenting with sudden flank pain.

  7. Additional value of FDG-PET to contrast enhanced-computed tomography (CT) for the diagnosis of mediastinal lymph node metastasis in non-small cell lung cancer. A Japanese multicenter clinical study

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Murakami, Koji; Inoue, Tomio; Itoh, Harumi; Saga, Tsuneo; Shiomi, Susumu; Hatazawa, Jun

    2011-01-01

    This study was a controlled multicenter clinical study to verify the diagnostic effects of additional fluorodeoxyglucose-positron emission tomography (FDG-PET) to contrast-enhanced CT for mediastinal lymph node metastasis in patients with operable non-small cell lung cancer (NSCLC). NSCLC patients with enlarged mediastinal lymph nodes (short diameter, 7-20 mm), confirmed using contrast-enhanced CT, were examined using FDG-PET to detect metastases prior to surgery. The primary endpoint was the accuracy for concomitantly used CT and FDG-PET showing the additional effects of FDG, compared with CT alone. The secondary endpoints were the clinical impact of FDG-PET on therapeutic decisions and adverse reaction from FDG administration. The images were interpreted by investigators at each institution. Moreover, blinded readings were performed by an image interpretation committee independent of the institutions. The gold standard was the pathological diagnosis determined by surgery or biopsy after PET, and patients in whom a pathological diagnosis was not obtained were excluded from the analysis. Among 99 subjects, the results for 81 subjects eligible for analysis showed that the accuracy improved from 69.1% (56/81) for CT alone to 75.3% (61/81) for CT + PET (p=0.404). These findings contributed to treatment decisions in 63.0% (51/81) of the cases, mainly with regard to the selection of the operative procedure. The results of the image interpretation committee showed that the accuracy improved from 64.2% (52/81) (95% confidence interval (CI) 52.8-74.6) for CT to 75.3% (61/81) (95% CI 64.5-84.2) for CT + PET. The accuracy for 106 mediastinal lymph nodes improved significantly from 62.3% (66/106) (95% CI 52.3-71.5) for CT to 79.2% (84/106) (95% CI 70.3-86.5) for CT + PET (p<0.05). We found that no serious adverse drug reactions appeared in any of the 99 patients who received FDG, except for transient mild outliers in the laboratory data for two patients. The addition of FDG

  8. Application of contrast-enhanced ultrasound in the diagnosis of solid pancreatic lesions—A comparison of conventional ultrasound and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Fan, Zhihui; Li, Ying; Yan, Kun; Wu, Wei; Yin, Shanshan; Yang, Wei; Xing, Baocai

    2013-01-01

    Objective: To explore the diagnostic value of contrast-enhanced ultrasound (CEUS) by comparison with conventional ultrasound (US) and contrast-enhanced CT (CECT) in solid pancreatic lesions. Method: Ninety patients with solid pancreatic focal lesions were enrolled, including 36 cases of pancreatic carcinoma, 28 cases of pancreatitis, 6 cases of pancreatic neuroendocrine tumor, 12 cases of solid pseudopapillary tumor of the pancreas, 6 cases of pancreatic metastases, 1 case of cavernous hemolymphangioma and 1 case of lymphoma. US and CEUS were applied respectively for the diagnosis of a total of 90 cases of solid pancreatic lesions. The diagnostic results were scored on a 5-point scale. Results of CEUS were compared with CECT. Results: (1) 3-score cases (undetermined) diagnosed by CEUS were obviously fewer than that of US, while the number of 1-score (definitely benign) and 5-score (definitely malignant) cases diagnosed by CEUS was significantly more than that of US. There was a significant difference in the distribution of final scores using the two methods (p < 0.001). The overall diagnostic accuracies of the 90 cases for CEUS and US were 83.33% and 44.44%, respectively, which indicated an obvious advantage for CEUS (p < 0.001). (2) The diagnostic consistency among three ultrasound doctors: the kappa values calculated for US were 0.537, 0.444 and 0.525, compared with 0.748, 0.645 and 0.795 for CEUS. The interobserver agreement for CEUS was higher than that for US. (3) The sensitivity, specificity and accuracy of the diagnosis of pancreatic carcinoma with CEUS and CECT were 91.7% and 97.2%, 87.0% and 88.9%, and 88.9% and 92.2%, respectively, while for the diagnosis of pancreatitis, the corresponding indices were 82.1% and 67.9%, 91.9% and 100%, and 88.9% and 90%, respectively, showing no significant differences (p > 0.05). Conclusion: CEUS has obvious superiority over conventional US in the general diagnostic accuracy of solid pancreatic lesions and in the

  9. Application of contrast-enhanced ultrasound in the diagnosis of solid pancreatic lesions—A comparison of conventional ultrasound and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Zhihui, E-mail: fanzhihui_1026@163.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Li, Ying, E-mail: 18901033676@126.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Radiology, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yan, Kun, E-mail: ydbz@sina.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Wu, Wei, E-mail: wuwei@163.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yin, Shanshan, E-mail: yshshmd@yahoo.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yang, Wei, E-mail: weiwei02032001@gmail.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Xing, Baocai, E-mail: xinbaocai88@sina.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Hepatic Biliary and Pancreatic Surgery, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); and others

    2013-09-15

    Objective: To explore the diagnostic value of contrast-enhanced ultrasound (CEUS) by comparison with conventional ultrasound (US) and contrast-enhanced CT (CECT) in solid pancreatic lesions. Method: Ninety patients with solid pancreatic focal lesions were enrolled, including 36 cases of pancreatic carcinoma, 28 cases of pancreatitis, 6 cases of pancreatic neuroendocrine tumor, 12 cases of solid pseudopapillary tumor of the pancreas, 6 cases of pancreatic metastases, 1 case of cavernous hemolymphangioma and 1 case of lymphoma. US and CEUS were applied respectively for the diagnosis of a total of 90 cases of solid pancreatic lesions. The diagnostic results were scored on a 5-point scale. Results of CEUS were compared with CECT. Results: (1) 3-score cases (undetermined) diagnosed by CEUS were obviously fewer than that of US, while the number of 1-score (definitely benign) and 5-score (definitely malignant) cases diagnosed by CEUS was significantly more than that of US. There was a significant difference in the distribution of final scores using the two methods (p < 0.001). The overall diagnostic accuracies of the 90 cases for CEUS and US were 83.33% and 44.44%, respectively, which indicated an obvious advantage for CEUS (p < 0.001). (2) The diagnostic consistency among three ultrasound doctors: the kappa values calculated for US were 0.537, 0.444 and 0.525, compared with 0.748, 0.645 and 0.795 for CEUS. The interobserver agreement for CEUS was higher than that for US. (3) The sensitivity, specificity and accuracy of the diagnosis of pancreatic carcinoma with CEUS and CECT were 91.7% and 97.2%, 87.0% and 88.9%, and 88.9% and 92.2%, respectively, while for the diagnosis of pancreatitis, the corresponding indices were 82.1% and 67.9%, 91.9% and 100%, and 88.9% and 90%, respectively, showing no significant differences (p > 0.05). Conclusion: CEUS has obvious superiority over conventional US in the general diagnostic accuracy of solid pancreatic lesions and in the

  10. Efficacy of high iodine concentration contrast medium with saline pushing in hepatic CT in patients with chronic liver disease. Comparison of high doses-standard contrast medium concentration

    International Nuclear Information System (INIS)

    Matoba, Munetaka; Kondo, Tamaki; Nishikawa, Takahiro; Kuginuki, Yasuaki; Yokota, Hajime; Higashi, Kotaro; Tonami, Hisao

    2006-01-01

    The aim of this study was to compare the enhancement of liver parenchyama with high iodine concentration contrast medium with saline pushing to that with high doses standard iodine concentration in hepatic CT in patients with chronic liver disease. There was no statistically significant difference regarding to the enhancement of liver parenchyama between the 370 mgI/ml of contrast medium with saline pushing and high doses standard iodine concentration contrast medium. (author)

  11. Multicenter Comparison of Contrast-Enhanced FDG PET/CT and 64-Slice Multi-Detector-Row CT for Initial Staging and Response Evaluation at the End of Treatment in Patients With Lymphoma.

    Science.gov (United States)

    Gómez León, Nieves; Delgado-Bolton, Roberto C; Del Campo Del Val, Lourdes; Cabezas, Beatriz; Arranz, Reyes; García, Marta; Cannata, Jimena; González Ortega, Saturnino; Pérez Sáez, Mª Ángeles; López-Botet, Begoña; Rodríguez-Vigil, Beatriz; Mateo, Marta; Colletti, Patrick M; Rubello, Domenico; Carreras, José L

    2017-08-01

    To compare staging correctness between contrast-enhanced FDG PET/ceCT and 64-slice multi-detector-row CT (ceCT64) for initial staging and response evaluation at the end of treatment (EOT) in patients with Hodgkin lymphoma, diffuse large B cell lymphoma (DLBCL), and follicular lymphoma. This prospective study compared initial staging and response evaluation at EOT. One hundred eighty-one patients were randomly assigned to either ceCT64 or FDG PET/ceCT. A nuclear medicine physician and a radiologist read FDG PET/ceCT scans independently and achieved post hoc consensus, whereas another independent radiologist interpreted ceCT64 separately. The reference standard included all clinical information, all tests, and follow-up. Ethics committees of the participating centers approved the study, and all participants provided written consent. Ninety-one patients were randomized to ceCT64 and 90 to FDG PET/ceCT; 72 had Hodgkin lymphoma, 72 had DLBCL, and 37 had follicular lymphoma. There was excellent correlation between the reference standard and initial staging for both FDG PET/ceCT (κ = 0.96) and ceCT64 (κ = 0.84), although evaluation of the response at EOT was excellent only for FDG PET/ceCT (κ = 0.91). Our study demonstrated satisfactory agreement between FDG PET/ceCT (κ = 0.96) and ceCT64 (κ = 0.84) in initial staging compared with the reference standard (P = 0.16). Response evaluation at EOT with FDG PET/ceCT (κ = 0.91) was superior compared with ceCT64 (κ = 0.307) (P < 0.001).

  12. Contrast-enhanced ultrasound in the diagnosis of nodules in liver cirrhosis.

    Science.gov (United States)

    Kim, Tae Kyoung; Jang, Hyun-Jung

    2014-04-07

    Contrast-enhanced ultrasound (CEUS) using microbubble contrast agents are useful for the diagnosis of the nodules in liver cirrhosis. CEUS can be used as a problem-solving method for indeterminate nodules on computed tomography (CT) or magnetic resonance imaging (MRI) or as an initial diagnostic test for small newly detected liver nodules. CEUS has unique advantages over CT and MRI including no renal excretion of contrast, real-time imaging capability, and purely intravascular contrast. Hepatocellular carcinoma (HCC) is characterized by arterial-phase hypervascularity and later washout (negative enhancement). Benign nodules such as regenerative nodules or dysplastic nodules are usually isoechoic or slightly hypoechoic in the arterial phase and isoechoic in the late phase. However, there are occasional HCC lesions with atypical enhancement including hypovascular HCC and hypervascular HCC without washout. Cholangiocarcinomas are infrequently detected during HCC surveillance and mostly show rim-like or diffuse hypervascularity followed by rapid washout. Hemangiomas are often found at HCC surveillance and are easily diagnosed by CEUS. CEUS can be effectively used in the diagnostic work-up of small nodules detected at HCC surveillance. CEUS is also useful to differentiate malignant and benign venous thrombosis and to guide and monitor the local ablation therapy for HCC.

  13. Multi-detector CT urography: effect of oral hydration and contrast medium volume on renal parenchymal enhancement and urinary tract opacification - a quantitative and qualitative analysis

    International Nuclear Information System (INIS)

    Szolar, Dieter H.; Tillich, Manfred; Preidler, Klaus W.

    2010-01-01

    To assess the effect of oral hydration and contrast-medium volume on renal enhancement and urinary tract opacification in multi-detector CT urography. A total of 192 patients were assigned to different protocols with varying doses of contrast agent with and without oral hydration. The attenuation was measured in the renal parenchyma in the unenhanced, nephrographic and excretory phase, and in the urinary tract in excretory phase imaging, respectively. Opacification of the urinary tract was graded on volume rendered images. Oral hydration did not significantly alter renal parenchymal enhancement in both the nephrographic and the excretory phase (p > 0.001), but significantly decreased mean attenuation of the urinary tract in the excretory phase (p ≤ 0.001), and improved continuous opacification of all ureter segments (p < 0.01). Higher volumes of contrast medium improved renal parenchymal enhancement (p ≤ 0.001) and continuous opacification of the urinary tract (p ≤ 0.01). Oral hydration leads to lower attenuation values in the urinary tract but improves the continuous opacification of the tract. Increase in contrast medium volume leads to higher renal parenchymal enhancement as well as to an increased continuous opacification of the urinary tract. Decrease in contrast medium volume cannot be compensated for by oral hydration in terms of parenchymal enhancement. (orig.)

  14. Contrast-enhanced ultrasonography for the determination of Crohn's disease activity - preliminary experience.

    Science.gov (United States)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Kłopocka, Maria; Liebert, Ariel; Lemanowicz, Adam; Serafin, Zbigniew

    2014-01-01

    Contrast-enhanced ultrasound (CEUS) is a recent non-invasive modality, which may partially replace currently used techniques (endoscopy, CT enterography and MR enterography) in the diagnostics and assessment of Crohn's disease (CD). The aim of the study was to analyze early experience in the use of CEUS for the measurement of activity and staging of CD. Eleven patients previously diagnosed with CD were included in the study. They underwent contrast-enhanced ultrasonography (SonoVue, Bracco), low-dose CT enterography (LDCTE), assessment of laboratory markers of inflammation and clinical CD activity index (CDAI). Contrast enhancement was evaluated using a semi-quantitative method and a quantitative method that included measurement of peak enhancement (PE), enhancement curve rise time (RT) and wash-in-rate (WiR). Ileal wall thickening was observed in all patients. Semi-quantitative method was used to observe CD activity in CEUS in 10 cases that perfectly matched LDCTE findings. There was a moderate positive correlation between PE and CDAI (r=0.65, p<0.001). There was no significant relationship between perfusion parameters and laboratory markers of inflammation. CEUS is a promising modality for non-invasive assessment of pathologic ileal vascularization in the course of Crohn's disease. Intensity of enhancement in CEUS reflects activity of the disease detected in LDCTE and correlates with CDAI.

  15. Hepatic entropy and uniformity: additional parameters that can potentially increase the effectiveness of contrast enhancement during abdominal CT

    International Nuclear Information System (INIS)

    Ganeshan, B.; Miles, K.A.; Young, R.C.D.; Chatwin, C.R.

    2007-01-01

    Aim: To determine how hepatic entropy and uniformity of computed tomography (CT) images of the liver change after the administration of contrast material and to assess whether these additional parameters are more sensitive to tumour-related changes in the liver than measurements of hepatic attenuation or perfusion. Materials and methods: Hepatic attenuation, entropy, uniformity, and perfusion were measured using multi-phase CT following resection of colorectal cancer. Based on conventional CT and fluorodeoxyglucose positron emission tomography, 12 patients were classified as having no evidence of malignancy, eight with extra-hepatic tumours only, and eight with metastatic liver disease. Results: Hepatic attenuation and entropy increased after CM administration whereas uniformity decreased. Unlike hepatic attenuation, entropy and uniformity changed maximally in the arterial phase. No significant differences in hepatic perfusion or attenuation were found between patient groups, whereas arterial-phase entropy was lower (p = 0.034) and arterial-phase uniformity was higher (p = 0.034) in apparently disease-free areas of liver in patients with hepatic metastases compared with those with no metastases. Conclusion: Temporal changes in hepatic entropy and uniformity differ from those for hepatic attenuation. By reflecting the distribution of hepatic enhancement, these additional parameters are more sensitive to tumour-related changes in the liver than measurements of hepatic attenuation or perfusion

  16. Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm

    International Nuclear Information System (INIS)

    Ahmadian, Alireza; Ay, Mohammad R.; Sarkar, Saeed; Bidgoli, Javad H.; Zaidi, Habib

    2008-01-01

    Oral contrast is usually administered in most X-ray computed tomography (CT) examinations of the abdomen and the pelvis as it allows more accurate identification of the bowel and facilitates the interpretation of abdominal and pelvic CT studies. However, the misclassification of contrast medium with high-density bone in CT-based attenuation correction (CTAC) is known to generate artifacts in the attenuation map (μmap), thus resulting in overcorrection for attenuation of positron emission tomography (PET) images. In this study, we developed an automated algorithm for segmentation and classification of regions containing oral contrast medium to correct for artifacts in CT-attenuation-corrected PET images using the segmented contrast correction (SCC) algorithm. The proposed algorithm consists of two steps: first, high CT number object segmentation using combined region- and boundary-based segmentation and second, object classification to bone and contrast agent using a knowledge-based nonlinear fuzzy classifier. Thereafter, the CT numbers of pixels belonging to the region classified as contrast medium are substituted with their equivalent effective bone CT numbers using the SCC algorithm. The generated CT images are then down-sampled followed by Gaussian smoothing to match the resolution of PET images. A piecewise calibration curve was then used to convert CT pixel values to linear attenuation coefficients at 511 keV. The visual assessment of segmented regions performed by an experienced radiologist confirmed the accuracy of the segmentation and classification algorithms for delineation of contrast-enhanced regions in clinical CT images. The quantitative analysis of generated μmaps of 21 clinical CT colonoscopy datasets showed an overestimation ranging between 24.4% and 37.3% in the 3D-classified regions depending on their volume and the concentration of contrast medium. Two PET/CT studies known to be problematic demonstrated the applicability of the technique in

  17. Recurrent postoperative sciatica: Evaluation with MR imaging and enhanced CT

    International Nuclear Information System (INIS)

    Duoauferrier, R.; Frocrain, L.; Husson, J.L.

    1987-01-01

    The authors prospectively compared surface coil MR (SCMR) imaging and CT with iodinate contrast enhancement in 50 patients with recurrent postoperative sciatica. Of the 50 patients enrolled in the study, surgical treatment was elected in 27 patients after independent examination of SCMR imaging and enhanced CT. All predictions made with the 27 SCMR images were surgically confirmed. The surgical findings were 20 recurrent disk herniations, five recurrent disk herniations with scar tissue, one disk herniation above the level of diskectomy, and one disk herniation below the level of diskectomy. The surgical findings of the 12 patients who had scar tissue on CT were seven recurrent disk herniations, four recurrent disk herniations with scar tissue, and one disk herniation below the operated level. SCMR imaging was more sensitive and more specific than CT to differentiate scar tissue from recurrent disk herniation

  18. Detectability index of differential phase contrast CT compared with conventional CT: a preliminary channelized Hotelling observer study

    Science.gov (United States)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2013-03-01

    Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.

  19. Three-dimensional contrast-enhanced MRI using an intravascular contrast agent for detection of traumatic intra-abdominal hemorrhage and abdominal parenchymal injuries: an experimental study

    International Nuclear Information System (INIS)

    Weishaupt, D.; Ruehm, S.G.; Patak, M.A.; Schmidt, M.; Debatin, J.F.; Hetzer, F.H.

    2000-01-01

    The aim of this study was to compare the performance of 3D MRI in conjunction with an intravascular contrast agent to spiral contrast-enhanced CT, regarding the detection of abdominal parenchymal injuries as well as peritoneal hemorrhage in an animal model. Liver and kidney injuries were created surgically in six female pigs under general anesthesia. All pigs underwent contrast-enhanced spiral CT and 3D MR imaging following administration of an intravascular contrast agent (NC100150 Injection). Two readers rated their confidence independently on MR and CT data sets using a five-point scale for the presence of organ injury and hemoperitoneum. Autopsy findings served as standard of reference. Sensitivity and specificity for MR in detecting hepatic and renal injuries as well as hemoperitoneum was 100 %. Computed tomography was less accurate with sensitivity and specificity values of 90 and 94 %, respectively. Receiver operating characteristics (ROC) analysis revealed a higher confidence when interpretation was based on MR images. In an animal model 3D MR imaging in conjunction with an intravascular contrast agent proved highly accurate in detecting and localizing parenchymal injuries to the upper abdomen as well as in detecting intraperitoneal blood collections. (orig.)

  20. [18F]Fluorodeoxyglucose (FDG)-Positron Emission Tomography (PET)/Computed Tomography (CT) in Suspected Recurrent Breast Cancer: A Prospective Comparative Study of Dual-Time-Point FDG-PET/CT, Contrast-Enhanced CT, and Bone Scintigraphy.

    Science.gov (United States)

    Hildebrandt, Malene Grubbe; Gerke, Oke; Baun, Christina; Falch, Kirsten; Hansen, Jeanette Ansholm; Farahani, Ziba Ahangarani; Petersen, Henrik; Larsen, Lisbet Brønsro; Duvnjak, Sandra; Buskevica, Inguna; Bektas, Selma; Søe, Katrine; Jylling, Anne Marie Bak; Ewertz, Marianne; Alavi, Abass; Høilund-Carlsen, Poul Flemming

    2016-06-01

    To prospectively investigate the diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) with dual-time-point imaging, contrast-enhanced CT (ceCT), and bone scintigraphy (BS) in patients with suspected breast cancer recurrence. One hundred women with suspected recurrence of breast cancer underwent 1-hour and 3-hour FDG-PET/CT, ceCT, and BS within approximately 10 days. The study was powered to estimate the precision of the individual imaging tests. Images were visually interpreted using a four-point assessment scale, and readers were blinded to other test results. The reference standard was biopsy along with treatment decisions and clinical follow-up (median, 17 months). FDG-PET/CT resulted in no false negatives and fewer false positives than the other imaging techniques. Accuracy of results were similar for 1-hour and 3-hour FDG-PET/CT. For distant recurrence, the area under the receiver operating curve was 0.99 (95% CI, 0.97 to 1) for FDG-PET/CT, 0.84 (95% CI, 0.73 to 0.94) for ceCT, and 0.86 (95% CI, 0.77 to 0.94) for the combined ceCT+BS. Of 100 patients, 22 (22%) were verified with distant recurrence, and 18 of these had bone involvement. Nineteen patients (19%) had local recurrence only. In exploratory analyses, diagnostic accuracy of FDG-PET/CT was better than ceCT alone or ceCT combined with BS in diagnosing distant, bone, and local recurrence, shown by a greater area under the receiver operating curve and higher sensitivity, specificity, and superior likelihood ratios. FDG-PET/CT was accurate in diagnosing recurrence in breast cancer patients. It allowed for distant recurrence to be correctly ruled out and resulted in only a small number of false-positive cases. Exploratory findings suggest that FDG-PET/CT has greater accuracy than conventional imaging technologies in this patient group. © 2016 by American Society of Clinical Oncology.

  1. Synchrotron-based DEI for bio-imaging and DEI-CT to image phantoms with contrast agents

    International Nuclear Information System (INIS)

    Rao, Donepudi V.; Swapna, Medasani; Cesareo, Roberto; Brunetti, Antonio; Akatsuka, Tako; Yuasa, Tetsuya; Zhong, Zhong; Takeda, Tohoru; Gigante, Giovanni E.

    2012-01-01

    The introduction of water, physiological, or iodine as contrast agents is shown to enhance minute image features in synchrotron-based X-ray diffraction radiographic and tomographic imaging. Anatomical features of rat kidney, such as papillary ducts, ureter, renal artery and renal vein are clearly distinguishable. Olfactory bulb, olfactory tact, and descending bundles of the rat brain are visible with improved contrast. - Highlights: ► Distinguishable anatomical structures features of rat kidney and rat brain are acquired with Sy-DEI in planar mode. ► Images of a small brain phantom and cylindrical phantom are acquired in tomography mode (Sy-DEI-CT) with contrast agents. ► Sy-DEI and Sy-DEI-CT techniques provide new source of information related to biological microanatomy.

  2. Quantitative evaluation in enhancement of pancreas and adjacent vessels during spiral CT

    International Nuclear Information System (INIS)

    Kim, Hyoung Seuk; Shin, Kue Hee; Park, Cheol Min; Cha, Sang Hoon; Chung, Kyoo Byung

    1997-01-01

    To determine by quantitative evaluation of pancreatic and adjacent vascular enhancement during spiral CT, the ideal scan delay for examination of the pancreas. Dual(n=3D90) and triple(n=3D90) phase spiral CT scans of patients whose pancreas showed no pathologic condition were retrospectively evaluated. Dual-phase scans were performed at 43 seconds(early), and 5-6 minutes(delayed) after the injection of 120ml of contrast material at an injection rate of 3ml/sec;triple-phase scans were performed at 25 seconds(arterial),60-65 seconds (portal) and 5-6 minutes (delayed) after the injection of 120-140ml of contrast material at an injection rate of 2-4ml/sec, and ten patients also underwent precontrast scanning. CT attenuation values(HU) were measured in the head, body and tail of the pancreas, aorta, and main portal vein during each phase of all scans. Triple-phase protocol was used to measure the effect of different total volumes and injection rates on enhancement of the pancreas and adjacent vessels. There was no significant difference in the degree of enhancement of the pancreas head, body and tail during each phase(p>0.05). The pancreas was maximally enhanced on 43 second delayed scan(132±20HU)(p 0.05). The main portal vein showed maximum enhancement on 43-second delayed scan(207±44HU)(p<0.05). Different total volume of contrast material did not change the enhancement of the pancreas and adjacent vessels. At an injection rate of 2ml/sec, peak enhancement of the pancreas, aorta and portal vein was obtained on 60-65 second delayed scan, and at 4ml/sec, peak enhancement was obtained on 25 second delayed scan(p<0.05). Observing the usual protocols for abdominal spiral CT scanning, the pancreas was most effectively evaluated using a 43-second delayed scan. An increased injection rate resulted in earlier enhancement of the pancreas, aorta and portal vein

  3. A study of the indication for conservative surgery in adult hydronephrosis based on presurgery post-contrast computed tomography (CT) finding

    International Nuclear Information System (INIS)

    Kawai, Noriyasu; Tsugaya, Masayuki; Sakagami, Hiroshi; Sasaki, Shoichi; Kohri, Kenjiro

    1997-01-01

    The cases with adult hydronephrosis are usually performed either conservative surgery or nephrectomy according to the grade of residual renal function. The residual renal function of adult hydronephrosis are usually suspected with analysis of concentration and/or clearance of the renal urine content after percutaneous nephrostomy. However, percutaneous nephrostomy is invasive and risky. On the other hand, post-contrast computed tomography (CT) is non-invasive. We studied whether post-contrast CT is available for the assessment of residual renal function of adult hydronephrosis and also studied the indication for conservative surgery of adult hydronephrosis on post-contrast CT. Conservative surgery or nephrectomy was performed in 14 patients with adult hydronephrosis in the duration from April, 1986 to March, 1995. All of 14 patients (14 kidneys) hydronephrosis were retrospectively studied of the character in the indication for conservative surgery by post-contrast CT before surgery. The indication for conservative surgery of adult hydronephrosis on post-contrast CT are well enhanced renal parenchyma exist round the kidney, even if it is very thin, and excretion of contrast medium to renal calyx are showed. It was concluded that post-contrast CT might be useful for the assessment of residual renal function of adult hydronephrosis. (author)

  4. Monte Carlo dosimetry of iodine contrast objects in a small animal microCT

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Villafuerte, M., E-mail: mercedes@fisica.unam.mx [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico); Martinez-Davalos, A. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico)

    2011-08-21

    Small animal microcomputed tomography (microCT) studies with iodine-based contrast media are commonly used in preclinical research. While the use of contrast media improves the quality of the images, it can also result in an increase in the absorbed dose to organs with high concentration of the contrast agent, which might cause radiation damage to the animal. In this work we present the results of a Monte Carlo investigation of a microCT dosimetry study using mouse-sized cylindrical water phantoms with iodine contrast insets for different X-ray spectra (Mo and W targets, 30-80 kVp), iodine concentrations (0, 5, 10 and 15 mg mL{sup -1}) and contrast object sizes (3 and 10 mm diameter). Our results indicate an absorbed dose increase in the contrast-inset regions with respect to the absorbed dose distribution within a reference uniform water phantom. The calculated spatial absorbed dose distributions show large gradients due to beam hardening effects, and large absorbed dose enhancement as the mean energy of the beam and iodine concentration increase. We have found that absorbed doses in iodine contrast objects can increase by a factor of up to 12 for a realistic 80 kVp X-ray spectra and an iodine concentration of 15 mg mL{sup -1}.

  5. Different contrast injection protocols for 64-slice spiral CT coronary angiography

    International Nuclear Information System (INIS)

    Lu Jinguo; Lv Bing; Bai Hua; Tang Xiang; Yang Xinling; Jiang Shiliang; Dai Ruiping; Qiu Jinhai; Chen Tao

    2008-01-01

    Objective: To determine the optimal contrast protocols for 64-slice spiral CT coronary angiography in order to reduce the volume of contrast injection. Methods: One hundred fifty patients scheduled to undergo 64-slice spiral CT coronary angiography were prospectively randomized into the following five groups with different injection protocols: group 1: uniphasic injection without a flush; group 2: biphasic injection with a flush; group 3, group 4 and group 5 : triphasic injection with a diluted contrast material with 3:7, 5:5, 7:3 contrast/saline ratio respectively. Attenuation was measured in the right atrium, right ventricle, left atrium, left ventricle, ascending aorta, right coronary artery and left coronary artery and analyzed with single factor variance test (ANOVA). The quality of the coronary artery images was evaluated and compared using person Chi-Square. Results: The total contrast material volume were (67.0±5.3) ml, (59.9±4.9) ml, (62.9±3.2) ml, (69.2±5.7) ml and (70.9±4.6) ml in five groups respectively (F=27.43, P 2 =18.81, P 2 =31.44, P<0.01). The artifacts in the superior vena cava in group 1 was the most, and in group 2 was the least. The mean enhancement values of right and left coronary arteries in group 2 were significantly greater than those in other groups (F=2.47 and 4.10, P<0.05). The visualization of both left ventricle and right ventricle cavities was the best in group 3. Conclusion: Biphasic injection and triphasic injection are better than uniphasic injection for 64-slice spiral CT coronary angiography and triphasic injection is better than biphasic injection for the visualization of both left ventricle and right ventricle cavities. (authors)

  6. Diagnostic Accuracy of Detecting Hashimoto's Thyroiditis in Thyroid Cancer Patients Who Underwent Thyroid Surgery: Comparison of Ultrasonography, Positron Emission Tomography/CT, Contrast Enhanced CT, and Anti-Thyroid Antibody

    International Nuclear Information System (INIS)

    Kim, Young Gyun; Lee, Tae Hyun; Park, Dong Hee; Nam, Sang Been

    2012-01-01

    To compare the diagnostic accuracy of ultrasonography (US), F18-fluorodeoxyglucose positron emission tomography/CT (PET/CT), contrast enhanced CT (CECT), serum anti-thyroid antibody for detecting Hashimoto's thyroiditis in thyroid cancer patients who underwent neck surgery. A total of 150 patients with suspicious for thyroid cancer, who had previously undergone US guided needle aspiration of thyroid, were evaluated with the use of US, PET/CT, CECT and serum anti-thyroid antibody. The four studies were performed within two months before neck surgery. Hashimoto's thyroiditis was confirmed by histopathological results. The diagnostic accuracy of US, PET/CT, CECT and serum anti-thyroid antibody were calculated statistically. Hashimoto's thyroiditis was diagnosed in 51 out of the 150 patients, following neck surgery. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of US were 76.5%, 92.9%, 84.8%, 88.5%, and 87.3%, respectively. The corresponding values of PET/CT were 37.3%, 96.0%, 82.6%, 74.8%, and 76.0%, and CECT were 62.7%, 89.9%, 76.2%, 82.4%, and 80.7%, and serum anti-thyroid antibody level were 90.2%, 93.9%, 88.5%, 94.9%, and 92.7%, respectively. McNemar test revealed significant difference among PET/CT and others, but no significant differences among US, CECT and serum anti-thyroid antibody. Overall, serum anti-thyroid antibody showed most accurate diagnostic performance. In detecting Hashimoto's thyroiditis, serum anti-thyroid antibody showed higher diagnostic accuracy than others. US also showed relatively high diagnostic accuracy.

  7. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  8. Studies on the consistency of internally taken contrast medium for pancreas CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Kishio; Mimura, Seiichi; Tahara, Seiji; Kitayama, Takuichi; Inamura, Keiji; Mikami, Yasutaka; Hashimoto, Keiji; Hiraki, Yoshio; Aono, Kaname

    1985-02-01

    A problem of Pancreatic CT scanning is the discrimination between the pancreas and the adjacent gastrointestinal tract. Generally we administer a dilution of gastrografin internally to make the discrimination. The degree of dilution has been decided by experience at each hospital. When the consistency of the contrast medium is low in density, an enhancement effect cannot be expected, but when the consistency is high, artifacts appear. We have experimented on the degree of the dilution and CT-No to decide the optimum consistency of gastrografin for the diagnosis of pancreatic disease. Statistical analysis of the results show the optimum dilution of gastrografin to be 1.5%.

  9. Dual-Energy CT in Enhancing Subdural Effusions that Masquerade as Subdural Hematomas: Diagnosis with Virtual High-Monochromatic (190-keV) Images.

    Science.gov (United States)

    Bodanapally, U K; Dreizin, D; Issa, G; Archer-Arroyo, K L; Sudini, K; Fleiter, T R

    2017-10-01

    Extravasation of iodinated contrast into subdural space following contrast-enhanced radiographic studies results in hyperdense subdural effusions, which can be mistaken as acute subdural hematomas on follow-up noncontrast head CTs. Our aim was to identify the factors associated with contrast-enhancing subdural effusion, characterize diffusion and washout kinetics of iodine in enhancing subdural effusion, and assess the utility of dual-energy CT in differentiating enhancing subdural effusion from subdural hematoma. We retrospectively analyzed follow-up head dual-energy CT studies in 423 patients with polytrauma who had undergone contrast-enhanced whole-body CT. Twenty-four patients with enhancing subdural effusion composed the study group, and 24 randomly selected patients with subdural hematoma were enrolled in the comparison group. Postprocessing with syngo.via was performed to determine the diffusion and washout kinetics of iodine. The sensitivity and specificity of dual-energy CT for the diagnosis of enhancing subdural effusion were determined with 120-kV, virtual monochromatic energy (190-keV) and virtual noncontrast images. Patients with enhancing subdural effusion were significantly older (mean, 69 years; 95% CI, 60-78 years; P subdural effusions was reached within the first 8 hours of contrast administration with a mean of 0.98 mg/mL (95% CI, 0.81-1.13 mg/mL), and complete washout was achieved at 38 hours. For the presence of a hyperdense subdural collection on 120-kV images with a loss of hyperattenuation on 190-keV and virtual noncontrast images, when considered as a true-positive for enhancing subdural effusion, the sensitivity was 100% (95% CI, 85.75%-100%) and the specificity was 91.67% (95% CI, 73%-99%). Dual-energy CT has a high sensitivity and specificity in differentiating enhancing subdural effusion from subdural hematoma. Hence, dual-energy CT has a potential to obviate follow-up studies. © 2017 by American Journal of Neuroradiology.

  10. MRI and CT contrast media extravasation: A systematic review.

    Science.gov (United States)

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H; Prince, Martin R

    2018-03-01

    This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT.

  11. Comparison of Accuracy of Contrast Enhanced Computed Tomography with Accuracy of Non-Contrast Magnetic Resonance Imaging in Evaluation of Local Extension of Base of Tongue Malignancies

    Directory of Open Access Journals (Sweden)

    Ketan Rathod

    2018-01-01

    Full Text Available Diagnosis of base of tongue malignancy can be obtained through clinical examination and biopsy. Magnetic Resonance Imaging (MRI and Computed Tomography (CT are used to detect its local extension, nodal spread and distant metastases. The main aim of study was to compare the accuracy of MRI and contrast enhanced CT in determining the local extent of base of tongue malignancy. Twenty five patients, biopsy proven cases of squamous cell carcinoma of base of tongue were taken. 1.5 Tesla Magnetic Resonance Unit with T2 weighted axial, coronal image; T1 weighted axial, coronal image; and STIR (Short tau inversion recovery axial and coronal images were used. 16 slice Computed Tomography unit with non-contrast and contrast enhanced images were used. Accuracy of CT to detect midline crossing: 50%; accuracy of MRI to detect midline crossing: 100%; accuracy of CT to detect anterior extension: 92%; accuracy of MRI to detect anterior extension: 100%; accuracy of CT to detect tonsillar fossa invasion: 83%; accuracy of MRI to detect tonsillar fossa invasion: 100%; accuracy of CT to detect oro pharyngeal spread: 83%; accuracy of MRI to detect oro pharyngeal spread: 100%; accuracy of CT to detect bone involvement: 20%; accuracy of MRI to detect bone involvement: 100%. MRI proved to be a better investigation than CT, in terms of evaluation of depth of invasion, presence of bony involvement, extension to opposite side, anterior half of tongue, tonsillar fossa, floor of mouth or oropharynx.

  12. Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface area

    International Nuclear Information System (INIS)

    Onishi, Hiromitsu; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Osuga, Keigo; Tatsumi, Mitsuaki; Higashihara, Hiroki; Maeda, Noboru; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tomoda, Kaname; Tomiyama, Noriyuki

    2011-01-01

    Purpose: To investigate the validity of determining the contrast medium dose based on body surface area (BSA) for the abdominal contrast-enhanced multi-detector row CT comparing with determining based on body weight (BW). Materials and methods: Institutional review committee approval was obtained. In this retrospective study, 191 patients those underwent abdominal contrast-enhanced multi-detector row CT were enrolled. All patients received 96 mL of 320 mg I/mL contrast medium at the rate of 3.2 mL. The iodine dose required to enhance 1 HU of the aorta at the arterial phase and that of liver parenchyma at portal venous phase per BSA were calculated (EU BSA ) and evaluated the relationship with BSA. Those per BW were also calculated (EU BW ) and evaluated. Estimated enhancement values (EEVs) of the aorta and liver parenchyma with two protocols for dose decision based on BSA and BW were calculated and patient-to-patient variability was compared between two protocols using the Levene test. Results: The mean of EU BSA and EU BW were 0.0621 g I/m 2 /HU and 0.00178 g I/kg/HU for the aorta, and 0.342 g I/m 2 /HU and 0.00978 g I/kg/HU for the liver parenchyma, respectively. In the aortic enhancement, EU BSA was almost constant regardless of BSA, and the mean absolute deviation of the EEV with the BSA protocol was significantly lower than that with the BW protocol (P < .001), although there was no significant difference between two protocols in the hepatic parenchymal enhancement (P = .92). Conclusion: For the aortic enhancement, determining the contrast medium dose based on BSA was considered to improve patient-to-patient enhancement variability.

  13. Influence of PSA, PSA velocity and PSA doubling time on contrast-enhanced 18F-choline PET/CT detection rate in patients with rising PSA after radical prostatectomy

    International Nuclear Information System (INIS)

    Schillaci, Orazio; Calabria, Ferdinando; Tavolozza, Mario; Caracciolo, Cristiana Ragano; Orlacchio, Antonio; Danieli, Roberta; Simonetti, Giovanni; Agro, Enrico Finazzi; Miano, Roberto

    2012-01-01

    To evaluate the accuracy of contrast-enhanced 18 F-choline PET/CT in restaging patients with prostate cancer after radical prostatectomy in relation to PSA, PSA velocity (PSAve) and PSA doubling time (PSAdt). PET/CT was performed in 49 patients (age range 58-87 years) with rising PSA (mean 4.13 ng/ml) who were divided in four groups according to PSA level: ≤1 ng/ml, 1 to ≤2 ng/ml, 2 to ≤4 ng/ml, and >4 ng/ml. PSAve and PSAdt were measured. PET and CT scans were interpreted separately and then together. PET/CT diagnosed relapse in 33 of the 49 patients (67%). The detection rates were 20%, 55%, 80% and 87% in the PSA groups ≤1, 1 to ≤2, 2 to ≤4 and >4 ng/ml, respectively. PET/CT was positive in 7 of 18 patients (38.9%) with a PSA ≤2 ng/ml, and in 26 of 31 (83.9%) with a PSA >2 ng/ml. PET/CT was positive in 7 of 25 patients (84%) with PSAdt ≤6 months, and in 12 of 24 patients (50%) with PSAdt >6 months, and was positive in 26 of 30 patients (86%) with a PSAve >2 ng/ml per year, and in 7 of 19 patients (36.8%) with PSAve ≤2 ng/ml per year. PET alone was positive in 31 of 49 patients (63.3%), and of these 31 patients, CT was negative in 14 but diagnosed bone lesions in 2 patients in whom PET alone was negative. CT with the administration of intravenous contrast medium did not provide any further information. Detection rate of 18 F-choline imaging is closely related to PSA and PSA kinetics. In particular, 18 F-choline PET/CT is recommended in patients with PSA >2 ng/ml, PSAdt ≤6 months and PSAve >2 ng/ml per year. CT is useful for detecting bone metastases that are not 18 F-choline-avid. The use of intravenous contrast agent seems unnecessary. (orig.)

  14. Intracranial ring enhancing lesions in dogs: a correlative CT scanning and neuropathologic study

    International Nuclear Information System (INIS)

    Wolf, Michael; Pedroia, Vince; Higgins, Robert J.; Koblik, Philip D.; Turrel, Jane M.; Owens, Jerry M.

    1995-01-01

    This retrospective analysis of 15 dogs with postcontrast ring enhancing brain lesions, each detected by a single Computed Tomography (CT) examination, searched for any association between their CT appearance and the pathologic diagnosis. In a subgroup of these dogs (n = 71) necropsied within 2 days of the last CT scan, we evaluated whether there was any anatomic correlation between the ring zone and the histopathologic features of the lesions. Our study consisted of eight dogs with primary brain tumors (3 meningiomas, 3 astrocytomas, 1 mixed glioma, 1 oligodendroglioma), 4 with metastatic brain tumors (2 fibrosarcomas, 1 mammary carcinoma, 1 melanoma) and 3 with non-neoplastic brain lesions (2 intraparenchymal hemorrhages, 1 pyogranulomatous meningoencephalitis). The overall size and shape of the contrast enhancing CT lesions, as well as the thickness, surface texture and degree of enhancement of the ring were subjectively evaluated. No association was found between the CT lesion characteristics and the pathologic diagnosis. In the sub-group of dogs euthanatized within 2 days of the CT examination, distinct histologic features which anatomically correlated with the zone of ring enhancement were found in 3 of 7 lesions. The findings of this study are consistent with those of ring-enhancing lesions in people, and indicates that CT ring enhancement is a nonspecific phenomenon which can occur in a variety of neoplastic and non-neoplastic lesions in the dog

  15. Prevalence of first-pass myocardial perfusion defects detected by contrast-enhanced dual-source CT in patients with non-ST segment elevation acute coronary syndromes

    Energy Technology Data Exchange (ETDEWEB)

    Schepis, Tiziano; Achenbach, Stephan; Marwan, Mohamed; Muschiol, Gerd; Ropers, Dieter; Daniel, Werner G.; Pflederer, Tobias [University of Erlangen, Department of Internal Medicine 2 (Cardiology), Erlangen (Germany)

    2010-07-15

    To investigate the prevalence and diagnostic value of first-pass myocardial perfusion defects (PD) visualised by contrast-enhanced multidetector computed tomography (MDCT) in patients admitted for a first acute coronary syndrome (ACS). Thirty-eight patients with non-ST segment elevation myocardial infarction (NSTEMI) or unstable angina (UA) and scheduled for percutaneous coronary intervention underwent dual-source CT immediately before catheterisation. CT images were analysed for the presence of any PD by using a 17-segment model. Results were compared with peak cardiac troponin-I (cTnI) and angiography findings. PD were seen in 21 of the 24 patients with NSTEMI (median peak cTnI level 7.07 ng/mL; range 0.72-37.07 ng/mL) and in 2 of 14 patients with UA. PD corresponded with the territory of the infarct-related artery in 20 out of 22 patients. In a patient-based analysis, sensitivity, specificity, negative and positive predictive values of any PD for predicting NSTEMI were 88%, 86%, 80% and 91%. Per culprit artery, the respective values were 86%, 75%, 80% and 83%. In patients with non-ST segment elevation ACS, first-pass myocardial PD in contrast-enhanced MDCT correlate closely with the presence of myocardial necrosis, as determined by increases in cTnI levels. (orig.)

  16. A theranostic dental pulp capping agent with improved MRI and CT contrast and biological properties.

    Science.gov (United States)

    Mastrogiacomo, S; Güvener, N; Dou, W; Alghamdi, H S; Camargo, W A; Cremers, J G O; Borm, P J A; Heerschap, A; Oosterwijk, E; Jansen, J A; Walboomers, X F

    2017-10-15

    Different materials have been used for vital dental pulp treatment. Preferably a pulp capping agent should show appropriate biological performance, excellent handling properties, and a good imaging contrast. These features can be delivered into a single material through the combination of therapeutic and diagnostic agents (i.e. theranostic). Calcium phosphate based composites (CPCs) are potentially ideal candidate for pulp treatment, although poor imaging contrast and poor dentino-inductive properties are limiting their clinical use. In this study, a theranostic dental pulp capping agent was developed. First, imaging properties of the CPC were improved by using a core-shell structured dual contrast agent (csDCA) consisting of superparamagnetic iron oxide (SPIO) and colloidal gold, as MRI and CT contrast agent respectively. Second, biological properties were implemented by using a dentinogenic factor (i.e. bone morphogenetic protein 2, BMP-2). The obtained CPC/csDCA/BMP-2 composite was tested in vivo, as direct pulp capping agent, in a male Habsi goat incisor model. Our outcomes showed no relevant alteration of the handling and mechanical properties (e.g. setting time, injectability, and compressive strength) by the incorporation of csDCA particles. In vivo results proved MRI contrast enhancement up to 7weeks. Incisors treated with BMP-2 showed improved tertiary dentin deposition as well as faster cement degradation as measured by µCT assessment. In conclusion, the presented theranostic agent matches the imaging and regenerative requirements for pulp capping applications. In this study, we combined diagnostic and therapeutic agents in order to developed a theranostic pulp capping agent with enhanced MRI and CT contrast and improved dentin regeneration ability. In our study we cover all the steps from material preparation, mechanical and in vitro characterization, to in vivo study in a goat dental model. To the best of our knowledge, this is the first time that a

  17. A prospective study on the risk of contrast induced nephropathy in the patients who underwent contrast-enhanced CT examination

    International Nuclear Information System (INIS)

    Zhang Baocui; Zhang Yudong; Zhao Kai; Wang Xiaoying; Jiang Xuexiang

    2013-01-01

    Objective: To investigate the incidence of contrast induced nephropathy (CIN) among different patient groups after contrast agent injection. Methods: A total of 1243 patients were included in this study (male = 694, female = 549). The SCr level one week before and 72 hours after the CT examination and the incidence of CIN were recorded and comparison was made among groups according to sex, age, body mass index (BMI), the history of high blood pressure (HBP), diabetes mellitus (DM), chronic kidney disease (CKD), chronic heart failure (CHF), tumor, nephrotoxicity drug (NTD) usage. The frequency, type, dose and injection velocity of the contrast media (CM) were also recorded. Multivariate predictors of CIN were identified by Logistic regression using step-wise selection with entry and exit criteria of P 1). Conclusion: Women, age ≥ 75 years, LOCM, NTD, tumor, and the frequency of using CM more than once per month were more likely to develop CIN. (authors)

  18. Multi-organ segmentation from multi-phase abdominal CT via 4D graphs using enhancement, shape and location optimization.

    Science.gov (United States)

    Linguraru, Marius George; Pura, John A; Chowdhury, Ananda S; Summers, Ronald M

    2010-01-01

    The interpretation of medical images benefits from anatomical and physiological priors to optimize computer-aided diagnosis (CAD) applications. Diagnosis also relies on the comprehensive analysis of multiple organs and quantitative measures of soft tissue. An automated method optimized for medical image data is presented for the simultaneous segmentation of four abdominal organs from 4D CT data using graph cuts. Contrast-enhanced CT scans were obtained at two phases: non-contrast and portal venous. Intra-patient data were spatially normalized by non-linear registration. Then 4D erosion using population historic information of contrast-enhanced liver, spleen, and kidneys was applied to multi-phase data to initialize the 4D graph and adapt to patient specific data. CT enhancement information and constraints on shape, from Parzen windows, and location, from a probabilistic atlas, were input into a new formulation of a 4D graph. Comparative results demonstrate the effects of appearance and enhancement, and shape and location on organ segmentation.

  19. Optimized enhancement in helical CT: Experiences with a real-time bolus tracking system in 628 patients

    International Nuclear Information System (INIS)

    Kirchner, J.; Kickuth, R.; Laufer, U.; Noack, M.; Liermann, D.

    2000-01-01

    AIMS: Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. MATERIALS AND METHODS: In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. RESULTS: There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). CONCLUSION: Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Kirchner, J. (2000). Clinical Radiology 55, 368-373

  20. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients.

    Science.gov (United States)

    Kirchner, J; Kickuth, R; Laufer, U; Noack, M; Liermann, D

    2000-05-01

    Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Copyright 2000 The Royal College of Radiologists.

  1. Evaluation of a low-dose CT protocol with oral contrast for assessment of acute appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Platon, Alexandra; Jlassi, Helmi; Becker, Christoph D.; Poletti, Pierre-Alexandre [University Hospital of Geneva, Department of Radiology, Geneva 14 (Switzerland); Rutschmann, Olivier T. [University Hospital of Geneva, Emergency Center, Geneva (Switzerland); Verdun, Francis R. [University Institute for Radiation Physics, Lausanne (Switzerland); Gervaz, Pascal [University Hospital of Geneva, Clinic of Digestive Surgery, Geneva (Switzerland)

    2009-02-15

    The aim of this study was to evaluate a low-dose CT with oral contrast medium (LDCT) for the diagnosis of acute appendicitis and compare its performance with standard-dose i.v. contrast-enhanced CT (standard CT) according to patients' BMIs. Eighty-six consecutive patients admitted with suspicion of acute appendicitis underwent LDCT (30 mAs), followed by standard CT (180 mAs). Both examinations were reviewed by two experienced radiologists for direct and indirect signs of appendicitis. Clinical and surgical follow-up was considered as the reference standard. Appendicitis was confirmed by surgery in 37 (43%) of the 86 patients. Twenty-nine (34%) patients eventually had an alternative discharge diagnosis to explain their abdominal pain. Clinical and biological follow-up was uneventful in 20 (23%) patients. LDCT and standard CT had the same sensitivity (100%, 33/33) and specificity (98%, 45/46) to diagnose appendicitis in patients with a body mass index (BMI) {>=} 18.5. In slim patients (BMI < 18.5), sensitivity to diagnose appendicitis was 50% (2/4) for LDCT and 100% (4/4) for standard CT, while specificity was identical for both techniques (67%, 2/3). LDCT may play a role in the diagnostic workup of patients with a BMI {>=} 18.5. (orig.)

  2. Evaluation of a low-dose CT protocol with oral contrast for assessment of acute appendicitis

    International Nuclear Information System (INIS)

    Platon, Alexandra; Jlassi, Helmi; Becker, Christoph D.; Poletti, Pierre-Alexandre; Rutschmann, Olivier T.; Verdun, Francis R.; Gervaz, Pascal

    2009-01-01

    The aim of this study was to evaluate a low-dose CT with oral contrast medium (LDCT) for the diagnosis of acute appendicitis and compare its performance with standard-dose i.v. contrast-enhanced CT (standard CT) according to patients' BMIs. Eighty-six consecutive patients admitted with suspicion of acute appendicitis underwent LDCT (30 mAs), followed by standard CT (180 mAs). Both examinations were reviewed by two experienced radiologists for direct and indirect signs of appendicitis. Clinical and surgical follow-up was considered as the reference standard. Appendicitis was confirmed by surgery in 37 (43%) of the 86 patients. Twenty-nine (34%) patients eventually had an alternative discharge diagnosis to explain their abdominal pain. Clinical and biological follow-up was uneventful in 20 (23%) patients. LDCT and standard CT had the same sensitivity (100%, 33/33) and specificity (98%, 45/46) to diagnose appendicitis in patients with a body mass index (BMI) ≥ 18.5. In slim patients (BMI < 18.5), sensitivity to diagnose appendicitis was 50% (2/4) for LDCT and 100% (4/4) for standard CT, while specificity was identical for both techniques (67%, 2/3). LDCT may play a role in the diagnostic workup of patients with a BMI ≥ 18.5. (orig.)

  3. Diagnostic accuracy of magnetic resonance, computed tomography and contrast enhanced ultrasound in radiological multimodality assessment of peribiliary liver metastases.

    Directory of Open Access Journals (Sweden)

    Vincenza Granata

    Full Text Available We compared diagnostic performance of Magnetic Resonance (MR, Computed Tomography (CT and Ultrasound (US with (CEUS and without contrast medium to identify peribiliary metastasis.We identified 35 subjects with histological proven peribiliary metastases who underwent CEUS, CT and MR study. Four radiologists evaluated the presence of peribiliary lesions, using a 4-point confidence scale. Echogenicity, density and T1-Weigthed (T1-W, T2-W and Diffusion Weighted Imaging (DWI signal intensity as well as the enhancement pattern during contrast studies on CEUS, CT and MR so as hepatobiliary-phase on MRI was assessed.All lesions were detected by MR. CT detected 8 lesions, while US/CEUS detected one lesion. According to the site of the lesion, respect to the bile duct and hepatic parenchyma: 19 (54.3% were periductal, 15 (42.8% were intra-periductal and 1 (2.8% was periductal-intrahepatic. According to the confidence scale MRI had the best diagnostic performance to assess the lesion. CT obtained lower diagnostic performance. There was no significant difference in MR signal intensity and contrast enhancement among all metastases (p>0.05. There was no significant difference in CT density and contrast enhancement among all metastases (p>0.05.MRI is the method of choice for biliary tract tumors but it does not allow a correct differential diagnosis among different histological types of metastasis. The presence of biliary tree dilatation without hepatic lesions on CT and US/CEUS study may be an indirect sign of peribiliary metastases and for this reason the patient should be evaluated by MRI.

  4. Contrast-enhanced helical CT of the pancreas. Optimal timing of imaging for pancreatic tumor evaluation

    International Nuclear Information System (INIS)

    Koide, Kazuki; Sekiguchi, Ryuzo

    2001-01-01

    We performed three-phase helical CT in patients suspected pancreatic tumors and investigated the optimal timing of imaging for evaluation of the pancreatic mass. The pancreatic-phase was superior in detecting pancreatic tumors, including islet cell tumors that may show strong enhancement. However, portal vein-phase imaging was also superior in 16.7% of our patients. Taking into account examination for hepatic metastasis, helical CT of any pancreatic tumor should include images obtained in the pancreatic and portal vein phases. (author)

  5. Body surface area adapted iopromide 300 mg/ml versus 370 mg/ml contrast medium injection protocol: Influence on quantitative and clinical assessment in combined PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Verburg, Frederik A., E-mail: fverburg@ukaachen.de [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Apitzsch, Jonas [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Lensing, Carina [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Kuhl, Christiane K. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Pietsch, Hubertus [Bayer Pharma AG, Müllerstrasse 178, 13353 Berlin (Germany); Mottaghy, Felix M. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Behrendt, Florian F. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany)

    2013-12-01

    Purpose: To investigate the quantitative and qualitative differences between combined positron emission tomography and computed X-ray tomography (PET/CT) enhanced with contrast medium with either an iodine concentration 300 mg/ml or 370 mg/ml. Materials and methods: 120 consecutive patients scheduled for F-18-Fluorodeoxyglucose (FDG) PET/CT were included. The first (second) 60 patients received contrast medium with 300 (370) mg iodine/ml. Intravenous injection protocols were adapted for an identical iodine delivery rate (1.3 mg/s) and body surface area (BSA) adapted iodine dose (22.26 g I/m{sup 2}). Maximum and mean standardized uptake values (SUV{sub max}; SUV{sub mean}) and contrast enhancement (HU) were determined in the ascending aorta, the abdominal aorta, the inferior vena cava, the portal vein, the liver and the right kidney in the venous contrast medium phase. PET data were evaluated visually for the presence of malignancy and image quality. Results: Both media caused significantly higher values for HU, SUV{sub mean} and SUV{sub max} for the enhanced PET/CT than the non-enhanced one (all p < 0.01). There were no significant differences in the degree of increase of HU, SUV{sub mean} and SUV{sub max} between the two contrast media at any anatomic site (all p > 0.05). Visual evaluation of lesions showed no differences between contrast and non-contrast PET/CT or between the two different contrast media (p = 0.77). Conclusion: When using a constant iodine delivery rate and total iodine dose in a BSA adapted injection protocol, there are no quantitative or qualitative differences in either CT or PET between contrast media with an iodine concentration of 300 mg/ml and 370 mg/ml, respectively.

  6. Contrast enhanced magnetic resonance imaging of the brain using gadolinium-DTPA

    International Nuclear Information System (INIS)

    Valk, J.; Slegte, R.G.M. de; Crezee, F.C.; Hazenberg, G.J.; Thjaha, S.I.; Nauta, J.J.P.; Vrije Univ., Amsterdam; Vrije Univ., Amsterdam; Vrije Univ., Amsterdam

    1987-01-01

    This report concerns a clinical trial with gadolinium-DTPA (Gd-DTPA) as an intravenous contrast medium for magnetic resonance imaging (MRI) in patients with disorders of the central nervous system. Fifty patients, 30 females and 20 males, were examined without and with Gd-GTPA. The contrast medium was well tolerated by all patients. The results of MRI scanning without and with Gd-DTPA and those obtained with computed tomography (CT) using intravenous contrast enhancement were compared. This investigation comprised mainly patients with intracranial tumors, multiple sclerosis, and nasopharyngeal tumors. The results may be summarized as follows: 1) MRI with Gd-DTPA (MRI+) gave better results than MRI without Gd as regards delineation of the lesion, blood vessels and edema in cerebral tumors, pituitary adenomas and acute forms of multiple sclerosis (MS). MRI+ was better than CT in 32 of the 50 cases examined; with intracerebral tumors it was better in 15 out of 18 cases. 3) MRI+ was always better than CT in patients with MS. In 3 out of 7 cases MRI demonstrated the acute MS lesions. 4) MRI+ seemed to have advantages also in nasopharyngeal tumors as ascertained from this limited experience. (orig.)

  7. Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Lundin, Margareta; Liden, Mats; Geijer, Haakan; Andersson, Torbjoern [Dept. of Radiology, Oerebro Univ. Hospital, Oerebro Univ., Oerebro (Sweden)], E-mail: margareta.lundin@orebroll.se; Magnuson, Anders [Clinical Epidemiology and Biostatistic Unit, Oerebro Univ. Hospital, Oerebro (Sweden); Mohammed, Ahmed Abdulilah [Dept. of Radiology, Linkoeping Univ. Hospital, Linkoeping (Sweden); Persson, Anders [CMIV Center for Medical Image Science and Visualization, Linkoeping (Sweden)

    2012-07-15

    Background. Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation. Purpose. To compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model. Material and Methods. Thirty patients referred for evaluation of hematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard. Results. The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition. Conclusion. Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However, the difference is smaller with the new compared to the older system.

  8. Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study.

    Science.gov (United States)

    Lundin, Margareta; Lidén, Mats; Magnuson, Anders; Mohammed, Ahmed Abdulilah; Geijer, Håkan; Andersson, Torbjörn; Persson, Anders

    2012-07-01

    Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation. To compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model. Thirty patients referred for evaluation of hematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard. The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition. Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However, the difference is smaller with the new compared to the older system.

  9. Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study

    International Nuclear Information System (INIS)

    Lundin, Margareta; Liden, Mats; Geijer, Haakan; Andersson, Torbjoern; Magnuson, Anders; Mohammed, Ahmed Abdulilah; Persson, Anders

    2012-01-01

    Background. Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation. Purpose. To compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model. Material and Methods. Thirty patients referred for evaluation of hematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard. Results. The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition. Conclusion. Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However, the difference is smaller with the new compared to the older system

  10. Influence of PSA, PSA velocity and PSA doubling time on contrast-enhanced {sup 18}F-choline PET/CT detection rate in patients with rising PSA after radical prostatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio [University ' ' Tor Vergata' ' , Department of Biopathology and Diagnostic Imaging, Interventional, Rome (Italy); IRCCS Neuromed, Department of Nuclear Medicine and Molecular Imaging, Pozzilli (Italy); Calabria, Ferdinando [IRCCS Neuromed, Department of Nuclear Medicine and Molecular Imaging, Pozzilli (Italy); Tavolozza, Mario; Caracciolo, Cristiana Ragano; Orlacchio, Antonio; Danieli, Roberta; Simonetti, Giovanni [University ' ' Tor Vergata' ' , Department of Biopathology and Diagnostic Imaging, Interventional, Rome (Italy); Agro, Enrico Finazzi; Miano, Roberto [University Hospital ' ' Tor Vergata' ' , Department of Urology, Rome (Italy)

    2012-04-15

    To evaluate the accuracy of contrast-enhanced {sup 18}F-choline PET/CT in restaging patients with prostate cancer after radical prostatectomy in relation to PSA, PSA velocity (PSAve) and PSA doubling time (PSAdt). PET/CT was performed in 49 patients (age range 58-87 years) with rising PSA (mean 4.13 ng/ml) who were divided in four groups according to PSA level: {<=}1 ng/ml, 1 to {<=}2 ng/ml, 2 to {<=}4 ng/ml, and >4 ng/ml. PSAve and PSAdt were measured. PET and CT scans were interpreted separately and then together. PET/CT diagnosed relapse in 33 of the 49 patients (67%). The detection rates were 20%, 55%, 80% and 87% in the PSA groups {<=}1, 1 to {<=}2, 2 to {<=}4 and >4 ng/ml, respectively. PET/CT was positive in 7 of 18 patients (38.9%) with a PSA {<=}2 ng/ml, and in 26 of 31 (83.9%) with a PSA >2 ng/ml. PET/CT was positive in 7 of 25 patients (84%) with PSAdt {<=}6 months, and in 12 of 24 patients (50%) with PSAdt >6 months, and was positive in 26 of 30 patients (86%) with a PSAve >2 ng/ml per year, and in 7 of 19 patients (36.8%) with PSAve {<=}2 ng/ml per year. PET alone was positive in 31 of 49 patients (63.3%), and of these 31 patients, CT was negative in 14 but diagnosed bone lesions in 2 patients in whom PET alone was negative. CT with the administration of intravenous contrast medium did not provide any further information. Detection rate of {sup 18}F-choline imaging is closely related to PSA and PSA kinetics. In particular, {sup 18}F-choline PET/CT is recommended in patients with PSA >2 ng/ml, PSAdt {<=}6 months and PSAve >2 ng/ml per year. CT is useful for detecting bone metastases that are not {sup 18}F-choline-avid. The use of intravenous contrast agent seems unnecessary. (orig.)

  11. Diagnostic Accuracy of Detecting Hashimoto's Thyroiditis in Thyroid Cancer Patients Who Underwent Thyroid Surgery: Comparison of Ultrasonography, Positron Emission Tomography/CT, Contrast Enhanced CT, and Anti-Thyroid Antibody

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Gyun; Lee, Tae Hyun; Park, Dong Hee; Nam, Sang Been [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To compare the diagnostic accuracy of ultrasonography (US), F18-fluorodeoxyglucose positron emission tomography/CT (PET/CT), contrast enhanced CT (CECT), serum anti-thyroid antibody for detecting Hashimoto's thyroiditis in thyroid cancer patients who underwent neck surgery. A total of 150 patients with suspicious for thyroid cancer, who had previously undergone US guided needle aspiration of thyroid, were evaluated with the use of US, PET/CT, CECT and serum anti-thyroid antibody. The four studies were performed within two months before neck surgery. Hashimoto's thyroiditis was confirmed by histopathological results. The diagnostic accuracy of US, PET/CT, CECT and serum anti-thyroid antibody were calculated statistically. Hashimoto's thyroiditis was diagnosed in 51 out of the 150 patients, following neck surgery. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of US were 76.5%, 92.9%, 84.8%, 88.5%, and 87.3%, respectively. The corresponding values of PET/CT were 37.3%, 96.0%, 82.6%, 74.8%, and 76.0%, and CECT were 62.7%, 89.9%, 76.2%, 82.4%, and 80.7%, and serum anti-thyroid antibody level were 90.2%, 93.9%, 88.5%, 94.9%, and 92.7%, respectively. McNemar test revealed significant difference among PET/CT and others, but no significant differences among US, CECT and serum anti-thyroid antibody. Overall, serum anti-thyroid antibody showed most accurate diagnostic performance. In detecting Hashimoto's thyroiditis, serum anti-thyroid antibody showed higher diagnostic accuracy than others. US also showed relatively high diagnostic accuracy.

  12. Low-dose quantitative phase contrast medical CT

    Science.gov (United States)

    Mittone, A.; Bravin, A.; Coan, P.

    2018-02-01

    X-ray computed tomography (CT) is a powerful and routinely used clinical diagnostic technique, which is well tolerated by patients, and which provides high-resolution images and volumetric information about the body. However, two important limitations still affect this examination procedure: (1) its low sensitivity with respect to soft tissues, and (2) the hazards associated with x-ray exposure. Conventional radiology is based on the detection of the different photon absorption properties that characterize biological tissues, and thus the obtainable image contrast from soft and/or similar tissues is intrinsically limited. In this scenario, x-ray phase contrast imaging (XPCI) has been extensively tested and proven to overcome some of the main issues surrounding standard x-ray imaging. In addition to the absorption signal, XPCI relies on detecting the phase shifts induced by an object. Interestingly, as the order of magnitude of the phase contrast is higher than that of absorption, XPCI can, in principle, offer higher sensitivity at lower radiation doses. However, other technical aspects may counterbalance this gain, and an optimized setup and image processing solutions need to be implemented. The work presented here describes the strategies and developments we have realized, with the aim of controlling the radiation dose for the highly sensitive and quantitative XPCI-CT. Different algorithms for the phase retrieval and CT reconstruction of the XPCI data are presented. The CT algorithms we have implemented, namely the equally sloped tomography and the dictionary learning method, allow the image quality to be preserved while reducing the number of angular projections required by a factor of five. The results applied to breast imaging report accurate reconstructions at clinically compatible doses of the 3D distribution of the refractive properties of full human organs obtained by using three different phase retrieval methods. The described methodologies and the

  13. PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients

    DEFF Research Database (Denmark)

    Berthelsen, A K; Holm, S; Loft, A

    2005-01-01

    PURPOSE: If the CT scan of a combined PET/CT study is performed as a full diagnostic quality CT scan including intravenous (IV) contrast agent, the quality of the joint PET/CT procedure is improved and a separate diagnostic CT scan can be avoided. CT with IV contrast can be used for PET attenuation...... correction, but this may result in a bias in the attenuation factors. The clinical significance of this bias has not been established. Our aim was to perform a prospective clinical study where each patient had CT performed with and without IV contrast agent to establish whether PET/CT with IV contrast can...... scans without, and then with contrast agent, followed by an 18F-fluorodeoxyglucose whole-body PET scan. The CT examinations were performed with identical parameters on a GE Discovery LS scanner. The PET data were reconstructed with attenuation correction based on the two CT data sets. A global...

  14. Contrast-enhanced ultrasonography for the determination of Crohn’s disease activity – preliminary experience

    Science.gov (United States)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Kłopocka, Maria; Liebert, Ariel; Lemanowicz, Adam; Serafin, Zbigniew

    2014-01-01

    Summary Background Contrast-enhanced ultrasound (CEUS) is a recent non-invasive modality, which may partially replace currently used techniques (endoscopy, CT enterography and MR enterography) in the diagnostics and assessment of Crohn’s disease (CD). The aim of the study was to analyze early experience in the use of CEUS for the measurement of activity and staging of CD. Material/Methods Eleven patients previously diagnosed with CD were included in the study. They underwent contrast-enhanced ultrasonography (SonoVue, Bracco), low-dose CT enterography (LDCTE), assessment of laboratory markers of inflammation and clinical CD activity index (CDAI). Contrast enhancement was evaluated using a semi-quantitative method and a quantitative method that included measurement of peak enhancement (PE), enhancement curve rise time (RT) and wash-in-rate (WiR). Results Ileal wall thickening was observed in all patients. Semi-quantitative method was used to observe CD activity in CEUS in 10 cases that perfectly matched LDCTE findings. There was a moderate positive correlation between PE and CDAI (r=0.65, p<0.001). There was no significant relationship between perfusion parameters and laboratory markers of inflammation. Conclusions CEUS is a promising modality for non-invasive assessment of pathologic ileal vascularization in the course of Crohn’s disease. Intensity of enhancement in CEUS reflects activity of the disease detected in LDCTE and correlates with CDAI. PMID:24723988

  15. Contrast-enhanced ultrasonography for the determination of Crohn’s disease activity – preliminary experience

    International Nuclear Information System (INIS)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Kłopocka, Maria; Liebert, Ariel; Lemanowicz, Adam; Serafin, Zbigniew

    2014-01-01

    Contrast-enhanced ultrasound (CEUS) is a recent non-invasive modality, which may partially replace currently used techniques (endoscopy, CT enterography and MR enterography) in the diagnostics and assessment of Crohn’s disease (CD). The aim of the study was to analyze early experience in the use of CEUS for the measurement of activity and staging of CD. Eleven patients previously diagnosed with CD were included in the study. They underwent contrast-enhanced ultrasonography (SonoVue, Bracco), low-dose CT enterography (LDCTE), assessment of laboratory markers of inflammation and clinical CD activity index (CDAI). Contrast enhancement was evaluated using a semi-quantitative method and a quantitative method that included measurement of peak enhancement (PE), enhancement curve rise time (RT) and wash-in-rate (WiR). Ileal wall thickening was observed in all patients. Semi-quantitative method was used to observe CD activity in CEUS in 10 cases that perfectly matched LDCTE findings. There was a moderate positive correlation between PE and CDAI (r=0.65, p<0.001). There was no significant relationship between perfusion parameters and laboratory markers of inflammation. CEUS is a promising modality for non-invasive assessment of pathologic ileal vascularization in the course of Crohn’s disease. Intensity of enhancement in CEUS reflects activity of the disease detected in LDCTE and correlates with CDAI

  16. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    Science.gov (United States)

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  17. Abdominal and pelvic CT: is positive enteric contrast still necessary? Results of a retrospective observational study.

    Science.gov (United States)

    Kammerer, S; Höink, A J; Wessling, J; Heinzow, H; Koch, R; Schuelke, C; Heindel, W; Buerke, B

    2015-03-01

    Evaluation of diagnostic accuracy of abdominal CT depending on the type of enteric contrast agent. Multislice CTs of 2,008 patients with different types of oral preparation (positive with barium, n = 576; neutral with water, n = 716; and no enteric contrast, n = 716) were retrospectively evaluated by two radiologists including delineation of intestinal segments and influence on diagnosis and diagnostic reliability exerted by the enteric contrast, using a three-point scale. Furthermore, diagnostic reliability of the delineation of selected enteric pathologies was noted. CT data were assigned into groups: oncology, inflammation, vascular, pathology, trauma and gastrointestinal pathology. Delineation of the bowel was clearly practicable across all segments irrespective of the type of enteric contrast, though a slight impairment was observed without enteric contrast. Although delineation of intestinal pathologies was mostly classified "clearly delimitable" more difficulties occurred without oral contrast (neutral/positive/no contrast, 0.8 %/3.8 %/6.5 %). Compared to examinations without enteric contrast, there was a significant improvement in diagnosis that was even increased regarding the reader's diagnostic reliability. Positive opacification impaired detection of mucosal enhancement or intestinal bleeding. Water can replace positive enteric contrast agents in abdominal CTs. However, selected clinical questions require individual enteric contrast preparations. Pathology detection is noticeably impaired without any enteric contrast.

  18. Multislice CT cholangiography without biliary contrast agent: technique and initial clinical results in the assessment of patients with biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Zandrino, F.; Benzi, L.; Ferretti, M.L.; Ferrando, R.; Reggiani, G.; Musante, F. [Department of Radiology, Azienda Ospedaliera ' ' SS Antonio e Biagio e C. Arrigo' ' , Alessandria (Italy)

    2002-05-01

    Our objective was to describe our technique for multislice CT cholangiography without cholangiographic contrast agent, and to present our preliminary clinical results. Thirty-seven patients with suspected biliary obstruction were studied. A multislice CT unit was used with the following technical parameters: 2.5-mm collimation; 7.5-mm/s table speed; pitch 6; 0.8-s rotation time; 300 mA; 120 kVp; 18- to 24-s scan time; scan volume ranging from the hepatic dome to below the pancreatic head; 70-s delay after injection of 150 ml of iodinated contrast agent at 4 ml/s. No biliary contrast material was given; oral iodinated contrast agent was administered to opacify bowel loops. Axial, multiplanar reformatted, and minimum intensity projection images were evaluated. The CT findings were compared with the gold standard techniques: endoscopic retrograde cholangiography (ERCP) in 30 patients, percutaneous transhepatic cholangiography in 5, and intraoperative cholangiography in 2. In 5 patients with ampullary lesions biopsy was made during ERCP, 9 underwent surgery, and 11 US-guided fine-needle aspiration. Bile ducts appeared hypodense within the surrounding enhanced structures. Regarding the site of obstruction, agreement between multislice CT and conventional cholangiography was observed in all cases. One patient presented negative findings on both CT and ERCP. In 31 of 36 (86%) patients, multislice CT cholangiography without cholangiographic contrast agent correctly assessed the cause of bile duct obstruction. Multislice CT cholangiography without cholangiographic contrast agent seems to be a promising diagnostic tool in the assessment of patients with bile duct obstruction. (orig.)

  19. Multislice CT cholangiography without biliary contrast agent: technique and initial clinical results in the assessment of patients with biliary obstruction

    International Nuclear Information System (INIS)

    Zandrino, F.; Benzi, L.; Ferretti, M.L.; Ferrando, R.; Reggiani, G.; Musante, F.

    2002-01-01

    Our objective was to describe our technique for multislice CT cholangiography without cholangiographic contrast agent, and to present our preliminary clinical results. Thirty-seven patients with suspected biliary obstruction were studied. A multislice CT unit was used with the following technical parameters: 2.5-mm collimation; 7.5-mm/s table speed; pitch 6; 0.8-s rotation time; 300 mA; 120 kVp; 18- to 24-s scan time; scan volume ranging from the hepatic dome to below the pancreatic head; 70-s delay after injection of 150 ml of iodinated contrast agent at 4 ml/s. No biliary contrast material was given; oral iodinated contrast agent was administered to opacify bowel loops. Axial, multiplanar reformatted, and minimum intensity projection images were evaluated. The CT findings were compared with the gold standard techniques: endoscopic retrograde cholangiography (ERCP) in 30 patients, percutaneous transhepatic cholangiography in 5, and intraoperative cholangiography in 2. In 5 patients with ampullary lesions biopsy was made during ERCP, 9 underwent surgery, and 11 US-guided fine-needle aspiration. Bile ducts appeared hypodense within the surrounding enhanced structures. Regarding the site of obstruction, agreement between multislice CT and conventional cholangiography was observed in all cases. One patient presented negative findings on both CT and ERCP. In 31 of 36 (86%) patients, multislice CT cholangiography without cholangiographic contrast agent correctly assessed the cause of bile duct obstruction. Multislice CT cholangiography without cholangiographic contrast agent seems to be a promising diagnostic tool in the assessment of patients with bile duct obstruction. (orig.)

  20. Choice of intravenous contrast material for CT

    International Nuclear Information System (INIS)

    Cohen, M.D.; Herman, E.; Herron, D.; White, S.T.; Smith, J.A.; Cory, D.A.

    1989-01-01

    For CT, minor side effects (e.g., nausea, vomiting, pain) following intravenous administration of contrast medium may degrade image quality by causing patient motion or by delaying scanning. The objective of this study was to see if nonionic contrast agents offer advantages in reducing the incidence of such side effects. One hundred five pediatric patients randomly received iohexol (Omnipaque), Iopamidol (Isovue), or diatrizoate sodium (Hypaque). Contrast medium was given in doses of 2 mL/kg body weight (300 mg of iodine per milliliter). The results are presented in the paper

  1. PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients

    International Nuclear Information System (INIS)

    Berthelsen, A.K.; Holm, S.; Loft, A.; Klausen, T.L.; Andersen, F.; Hoejgaard, L.

    2005-01-01

    If the CT scan of a combined PET/CT study is performed as a full diagnostic quality CT scan including intravenous (IV) contrast agent, the quality of the joint PET/CT procedure is improved and a separate diagnostic CT scan can be avoided. CT with IV contrast can be used for PET attenuation correction, but this may result in a bias in the attenuation factors. The clinical significance of this bias has not been established. Our aim was to perform a prospective clinical study where each patient had CT performed with and without IV contrast agent to establish whether PET/CT with IV contrast can be used for PET attenuation without reducing the clinical value of the PET scan. A uniform phantom study was used to document that the PET acquisition itself is not significantly influenced by the presence of IV contrast medium. Then, 19 patients referred to PET/CT with IV contrast underwent CT scans without, and then with contrast agent, followed by an 18 F-fluorodeoxyglucose whole-body PET scan. The CT examinations were performed with identical parameters on a GE Discovery LS scanner. The PET data were reconstructed with attenuation correction based on the two CT data sets. A global comparison of standard uptake value (SUV) was performed, and SUVs in tumour, in non-tumour tissue and in the subclavian vein were calculated. Clinical evaluation of the number and location of lesions on all PET/CT scans was performed twice, blinded and in a different random order, by two independent nuclear medicine specialists. In all patients, the measured global SUV of PET images based on CT with IV contrast agent was higher than the global activity using non-contrast correction. The overall increase in the mean SUV (for two different conversion tables tested) was 4.5±2.3% and 1.6±0.5%, respectively. In 11/19 patients, focal uptake was identified corresponding to malignant tumours. Eight out of 11 tumours showed an increased SUV max (2.9±3.1%) on the PET images reconstructed using IV contrast

  2. Autoimmune pancreatitis: Assessment of the enhanced duct sign on multiphase contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Kawai, Yuichi; Suzuki, Kojiro; Itoh, Shigeki; Takada, Akira; Mori, Yoshine; Naganawa, Shinji

    2012-01-01

    Purpose: To assess the usefulness of the computed tomography (CT) finding of main pancreatic duct (MPD) wall enhancement, termed the “enhanced duct sign”, for diagnosis of autoimmune pancreatitis (AIP) in comparison with diagnosis of pancreatic carcinoma and chronic pancreatitis. Materials and methods: Two radiologists independently evaluated the presence or absence of the enhanced duct sign on multiphase contrast-enhanced CT in patients with AIP (n = 55), pancreatic carcinoma (n = 50), and chronic pancreatitis (n = 50). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of AIP were calculated. In patients demonstrating the enhanced duct sign, additional findings were evaluated by consensus. Results: The enhanced duct sign was more frequently observed in patients with AIP (37/55, 67%) than in patients with pancreatic carcinoma (5/50, 10%) or chronic pancreatitis (0/50, 0%) (P < 0.05). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the finding were 0.67, 0.95, 0.85, 0.88, and 0.84, respectively. In AIP, the lumen within the enhanced duct was completely or partially invisible in 29 of 37 (78%) patients, and the enhanced duct was observed within the affected pancreatic parenchyma in 35 of 37 (95%) patients. In pancreatic carcinoma, the lumen within the enhanced duct was visible in all patients (5/5, 100%), and the enhanced duct was observed downstream of the tumor (5/5, 100%). Conclusion: The enhanced duct sign is highly specific of AIP.

  3. Autoimmune pancreatitis: Assessment of the enhanced duct sign on multiphase contrast-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Yuichi, E-mail: kawai.yuichi@a.mbox.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Suzuki, Kojiro, E-mail: kojiro@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Itoh, Shigeki, E-mail: shigeito@nagoya-1st.jrc.or.jp [Department of Diagnostic Radiology, Japan Red Cross Nagoya Daiichi Hospital, 3-35 Michishita-cho, Nakamura-ku, Nagoya 453-8511 (Japan); Takada, Akira, E-mail: takadaa@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Mori, Yoshine, E-mail: yoshine@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan); Naganawa, Shinji, E-mail: naganawa@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan)

    2012-11-15

    Purpose: To assess the usefulness of the computed tomography (CT) finding of main pancreatic duct (MPD) wall enhancement, termed the 'enhanced duct sign', for diagnosis of autoimmune pancreatitis (AIP) in comparison with diagnosis of pancreatic carcinoma and chronic pancreatitis. Materials and methods: Two radiologists independently evaluated the presence or absence of the enhanced duct sign on multiphase contrast-enhanced CT in patients with AIP (n = 55), pancreatic carcinoma (n = 50), and chronic pancreatitis (n = 50). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of AIP were calculated. In patients demonstrating the enhanced duct sign, additional findings were evaluated by consensus. Results: The enhanced duct sign was more frequently observed in patients with AIP (37/55, 67%) than in patients with pancreatic carcinoma (5/50, 10%) or chronic pancreatitis (0/50, 0%) (P < 0.05). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the finding were 0.67, 0.95, 0.85, 0.88, and 0.84, respectively. In AIP, the lumen within the enhanced duct was completely or partially invisible in 29 of 37 (78%) patients, and the enhanced duct was observed within the affected pancreatic parenchyma in 35 of 37 (95%) patients. In pancreatic carcinoma, the lumen within the enhanced duct was visible in all patients (5/5, 100%), and the enhanced duct was observed downstream of the tumor (5/5, 100%). Conclusion: The enhanced duct sign is highly specific of AIP.

  4. Contrast enhancement in the craniopharyngioma cyst wall caused by irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Eldevik, O.P.; Gabrielsen, T.O.; Altinok, D. [Univ. of Michigan Medical Center, Ann Arbor, MI (United States). Div. of Neuroradiology

    1998-03-01

    Purpose: To report the occurrence, degree, frequency, and duration of contrast enhancement in the craniopharyngioma cyst wall as caused by irradiation. Material and Methods: Eight patients with cystic craniopharyngiomas had comparable CT or MR studies before and after either external irradiation of the cyst (n=5) or {sup 32}P instillation into the cyst (n=3). Results: A minimal to marked increase in cyst-wall enhancement was seen at 66-157 days after {sup 32}P instillation in 3/3 cases and at 112-495 days after external irradiation in 3/5 cases. The increased enhancement was always associated with a variable interim increase in the thickness of the enhanced cyst wall. Conclusion: CT or MR imaging after the irradiation of cystic craniopharyngiomas usually demonstrated an increase in thickness and enhancement in the cyst wall. Such changes may be due to the irradiation alone and do not necessarily represent infection or increased neoplastic activity. The timing is uncertain as to the earliest possible development of such changes and their maximum duration, but they were seen as early as 66 days post-irradiation and as late as 495 days post-irradiation. (orig.).

  5. Contrast enhancement in the craniopharyngioma cyst wall caused by irradiation

    International Nuclear Information System (INIS)

    Eldevik, O.P.; Gabrielsen, T.O.; Altinok, D.

    1998-01-01

    Purpose: To report the occurrence, degree, frequency, and duration of contrast enhancement in the craniopharyngioma cyst wall as caused by irradiation. Material and Methods: Eight patients with cystic craniopharyngiomas had comparable CT or MR studies before and after either external irradiation of the cyst (n=5) or 32 P instillation into the cyst (n=3). Results: A minimal to marked increase in cyst-wall enhancement was seen at 66-157 days after 32 P instillation in 3/3 cases and at 112-495 days after external irradiation in 3/5 cases. The increased enhancement was always associated with a variable interim increase in the thickness of the enhanced cyst wall. Conclusion: CT or MR imaging after the irradiation of cystic craniopharyngiomas usually demonstrated an increase in thickness and enhancement in the cyst wall. Such changes may be due to the irradiation alone and do not necessarily represent infection or increased neoplastic activity. The timing is uncertain as to the earliest possible development of such changes and their maximum duration, but they were seen as early as 66 days post-irradiation and as late as 495 days post-irradiation. (orig.)

  6. Automated detection of acute haemorrhagic stroke in non-contrasted CT images

    International Nuclear Information System (INIS)

    Meetz, K.; Buelow, T.

    2007-01-01

    An efficient treatment of stroke patients implies a profound differential diagnosis that includes the detection of acute haematoma. The proposed approach provides an automated detection of acute haematoma, assisting the non-stroke expert in interpreting non-contrasted CT images. It consists of two steps: First, haematoma candidates are detected applying multilevel region growing approach based on a typical grey value characteristic. Second, true haematomas are differentiated from partial volume artefacts, relying on spatial features derived from distance-based histograms. This approach achieves a specificity of 77% and a sensitivity of 89.7% in detecting acute haematoma in non-contrasted CT images when applied to a set of 25 non-contrasted CT images. (orig.)

  7. Attenuation changes of the normal and ischemic canine kidney. Dynamic CT scanning after intravenous contrast medium bolus

    Energy Technology Data Exchange (ETDEWEB)

    Jaschke, W.; Lipton, M.J.; Boyd, D.P.; Cann, C.; Strauss, L.; Sievers, R.S.

    The potential of CT scanning to explore total and regional renal blood flow was evaluated in a dog model with unilateral renal artery stenosis (n=7, reduction of renal blood flow: 32-75% of base line flow). Attenuation versus time curves were generated for the renal cortex and medulla, as well as for the aorta and renal vein. A fast CT scanner was used which allowed for up to 24 scans/minute at the same level (slice thickness: 10 mm). A total of 10 ml contrast medim was injected into a peripheral vein for each scan series taken. During baseline conditions, the curve of the renal cortex and medulla demonstrated 2 peaks. The first peak was mainly related to early vascular enhancement, whereas the second peak corresponded mainly to the appearance of contrast medium in the distal convolutes and collecting ducts. Ischemia of the kidney resulted in a reduction of the first peak and a flattening of the leading edge slope. Transport of contrast medium through the extravascular compartments of the kidney was delayed during ischemia. Relative renal blood flow was obtained from the CT data by dividing peak enhancement by rise-time as assessed from the cortical curve. All measurements were related to baseline flow and validated by flow measurements using radioactive labeled microspheres (n=5). Correlation was found to be r=0.97. (orig.).

  8. Dynamic Contrast-Enhanced Perfusion Area-Detector CT: Preliminary Comparison of Diagnostic Performance for N Stage Assessment With FDG PET/CT in Non-Small Cell Lung Cancer.

    Science.gov (United States)

    Ohno, Yoshiharu; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Yoshikawa, Takeshi

    2017-11-01

    The objective of our study was to directly compare the capability of dynamic first-pass contrast-enhanced (CE) perfusion area-detector CT (ADCT) and FDG PET/CT for differentiation of metastatic from nonmetastatic lymph nodes and assessment of N stage in patients with non-small cell lung carcinoma (NSCLC). Seventy-seven consecutive patients, 45 men (mean age ± SD, 70.4 ± 5.9 years) and 32 women (71.2 ± 7.7 years), underwent dynamic first-pass CE-perfusion ADCT at two or three different positions for covering the entire thorax, FDG PET/CT, surgical treatment, and pathologic examination. From all ADCT data for each of the subjects, a whole-chest perfusion map was computationally generated using the dual- and single-input maximum slope and Patlak plot methods. For quantitative N stage assessment, perfusion parameters and the maximum standardized uptake value (SUV max ) for each lymph node were determined by measuring the relevant ROI. ROC curve analyses were performed for comparing the diagnostic capability of each of the methods on a per-node basis. N stages evaluated by each of the indexes were then statistically compared with the final pathologic diagnosis by means of chi-square and kappa statistics. The area under the ROC curve (A z ) values of systemic arterial perfusion (A z = 0.89), permeability surface (A z = 0.78), and SUV max (A z = 0.85) were significantly larger than the A z values of total perfusion (A z = 0.70, p Dynamic first-pass CE-perfusion ADCT is as useful as FDG PET/CT for the differentiation of metastatic from nonmetastatic lymph nodes and assessment of N stage in patients with NSCLC.

  9. Influence of hyperosmotic agent (glycerol) in contrast enhancement

    International Nuclear Information System (INIS)

    Moriyama, Takashi; Suzuki, Shigeharu; Nakaoka, Tsutomu

    1981-01-01

    For getting a better contrast enhancement (CE) of computed tomography (CT) in brain tumors, we tried to increase the extravascular iodine concentration. A vailing ourselves of the period of returning water following intravenously administered glycerol, a drip injection of the contrast medium gave a better CE effect than the usual CE. In two benign gliomas, CE with glycerol was much better than CE without glycerol, and in two malignant gliomas and two metastatic tumors, CE with glycerol was better, but not so much better as with the benign tumors. In general, the CE effect in primary brain tumors showed a decreasing pattern, whereas in metastatic brain tumors the best time was 60 minutes after the injection of the contrast material (increasing and decreasing pattern), suggesting an increase in the extravascular iodine and a severe failure of the blood brain barrier. Two cystic malignant gliomas allowed the intravenously injected contrast medium to enter the cysts. It appears that the contrast medium passes through and/or is secreted from the wall of the cyst. (author)

  10. Osmotic blood-brain barrier modification: clinical documentation by enhanced CT scanning and/or radionuclide brain scanning

    International Nuclear Information System (INIS)

    Neuwelt, E.A.; Specht, H.D.; Howieson, J.; Haines, J.E.; Bennett, M.J.; Hill, S.A.; Frenkel, E.P.

    1983-01-01

    Results of initial clinical trials of brain tumor chemotherapy after osmotic blood-brain barrier disruption are promising. In general, the procedure is well tolerated. The major complication has been seizures. In this report, data are presented which indicate that the etiology of these seizures is related to the use of contrast agent (meglumine iothalamate) to monitor barrier modification. A series of 19 patients underwent a total of 85 barrier modification procedures. Documentation of barrier disruption was monitored by contrast-enhanced computed tomographic (CT) scanning, radionuclide brain scanning, or a combination of both techniques. In 56 procedures (19 patients) monitored by enhanced CT, seizures occurred a total of 10 times in eight patients. Twenty-three barrier modification procedures (in nine of these 19 patients) documented by nuclear brain scans alone, however, resulted in only one focal motor seizure in each of two patients. In eight of the 19 patients who had seizures after barrier disruption and enhanced CT scan, four subsequently had repeat procedures monitored by radionuclide scan alone. In only one of these patients was further seizure activity noted; a single focal motor seizure was observed. Clearly, the radionuclide brain scan does not have the sensitivity and spatial resolution of enhanced CT, but at present it appears safer to monitor barrier modification by this method and to follow tumor growth between barrier modifications by enhanced CT. Four illustrative cases showing methods, problems, and promising results are presented

  11. Virtual non-contrast of liver from dual energy CT: a clinical application

    International Nuclear Information System (INIS)

    Qian Yu'e; Hu Hongjie; Zhang Qiaowei; Hu Peng; Shen Guohui

    2011-01-01

    Objective: To assess the virtual non-contrast liver CT from dual-energy CT for the clinical application. Methods: In total, 51 patients were included in the study, and all patients underwent multi-phase liver CT on a dual-source CT. The True non-contrast liver CT (TNCT) was performed in a single-energy acquisition mode, but the arterial and portovenous liver CT (VNCT) were performed in a dual- energy mode of 110 kV and 140 kV respectively. The virtual non-contrast CT images were derived from the arterial data using liver virtual non-contrast software. Between the true non-contrast CT and the virtual non- contrast CT, the image quality, mean CT HU values in the liver and muscle, signal to noise (SNR), the radiation dose of volume CT dose index (CTDIvol) and dose length product (DLP) in a single phase and total examination were compared with t test. Results: There was no significant difference in the detection of' liver lesions between TNCT and VNCT. The CT Hu values of muscle on both TNCT and VNCT images were almost equal. The CT HU values of liver on VNCT images were higher than that on TNCT images and the difference was significant [61.32±6.04 vs. (56.85±4.80) HU, t=-3.927, P<0.01]. There was also significant difference of SNR between TNCT (11.28±2.78) and VNCT (8.65±1.56) images (t=-5.590, P<0.01). The CTDIvol and DLP of single phase were (7.07±0.85) mGy and (155.11± 22.52) mGy · cm respectively in TNCT, and (7.05±0.87) mGy and (154.48±23.12) mGy · cm in VNCT. The total CTDIvol and DLP in VNCT were (14.35±1.66) mGy and (313.91±45.08) mGy · cm respectively, but in TNCT the total CTDIvol and DLP reached (21.43±2.46) mGy and (469.02± 66.22) mGy · cm. The difference of CTDIvol and DLP in single phase between TNCT and VNCT showed no significance, but the total CTDIvol and DLP were significantly different (t=16.168 and 13.132, P< 0.01). Conclusion: With the consequent reduction in radiation dose, the VNCT can replace TNCT as an imaging protocol in multi

  12. Diagnostic accuracy of C-arm CT during selective transcatheter angiography for hepatocellular carcinoma: comparison with intravenous contrast-enhanced, biphasic, dynamic MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Higashihara, Hiroki; Osuga, Keigo; Onishi, Hiromitsu; Nakamoto, Atsushi; Tsuboyama, Takahiro; Maeda, Noboru; Hori, Masatoshi; Kim, Tonsok; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan)

    2012-04-15

    This study was aimed to compare the accuracy, sensitivity, and positive predictive value of C-arm CT (CACT) during selective transcatheter angiography with those of multidetector CT (MDCT) in the detection of hepatocellular carcinoma (HCC). In this prospective study, 30 patients (mean age, 73 years) with unresectable HCC were examined with CACT before chemoembolisation. Images of a combination of CACT during arterial portography (CACTAP) and dual-phase CACT during hepatic arteriography (CACTHA) was obtained and images of intravenous contrast-enhanced, biphasic, dynamic, MDCT was also obtained beforehand. Three blinded observers independently reviewed CACT and MDCT. Diagnostic accuracy was evaluated by the alternative free-response receiver operating characteristic (AFROC) method. Sensitivities and positive predictive values (PPV) were analyzed with the paired t-test. In the mean area under the AFROC curve (Az), there was no significant difference between MDCT and CACT (MDCT, mean Az value, 0.83; CACT, 0.85, respectively) (P = 0.32). There was also no significant difference between the two techniques in sensitivity (MDCT, mean 0.65; CACT, 0.60) and PPV (MDCT, mean 0.98; CACT, 0.97) (P = 0.40, P = 0.68, respectively). The diagnostic accuracy of CACT was equivalent to that of biphasic CT in the diagnosis of HCC. (orig.)

  13. Posterior Urethra Rupture: Contrast-Enhanced Computed Tomography Scan and Urethrocystography Demonstrations

    Directory of Open Access Journals (Sweden)

    Wojciech Marks

    2012-01-01

    Full Text Available In the follow-up study of patients with pelvic fractures, rupture of the posterior urethra is registered in 3–25% of cases (Koraitim et al., 1996. The diagnostic gold standard for the assessment of hemodynamically stable trauma patients is contrast-enhanced CT scan, especially helical CT. Nevertheless, simultaneous suprapubic cystography and ascending urethrograms (the so-called up-and-downogram are the investigation of choice in assessing the site, severity, and length of urethral injuries. (Carlin and Resnick, 1995 This paper discusses the evaluation and diagnosis of urethral injury in multiple-trauma patient.

  14. Clinical application of multislice CT enterography with hypertonic mannitol saline as oral contrast

    International Nuclear Information System (INIS)

    Yan Guixin; Wang Haitao; Chen Wenjing; Liu Wenya

    2011-01-01

    Objective: To assess the feasibility and value of multislice CT enterography (MSCTE) with large dose economy and convenience orally administered hypertonic mannitol salt water (2.5% mannitol and 1.5% NaCl salt water) as negative contrast in demonstrating normal and abnormal small bowel. Methods: 81 patients suffered from digestive disease and suspected of various kinds of small intestinal diseases were examined (male/female=47/34, 26-81 years old, average 57.8 years). About 1500 ml∼3000 ml hypertonic mannitol saline was oral administered within 90 minutes and 20 mg of raceanisodamine hydrochloride injection was injected intramuscularly. CT scanning was performed 20 minutes later. Imaging data were post processed with coronal, sagittal and oblique reconstruction, multiplanar reformation (MPR), maximum intensity projection (MIP), and volumer rendering technique (VRT). The filling degree of stomach, intestine and colon was classified as satisfactory, better and unsatisfactory. The length and superposition of small intestine was classified as dense-type, uniformity-type and straggling-type. The maximum outer diameters of duodenum, jejunum, and ileum were measured respectively in different segments. The degree of bowel wall enhancement in arterial phase and venous phase was classified as obvious enhancement (>90 HU), medium enhancement (60-90 HU) and mild enhancement (<60 HU). CT features of various kinds of small bowel diseases were analyzed. Results: The hypertonic mannitol saline was acceptable by patients, except 5 patients with diarrhea. The filling degree of stomach, intestine and and colon was classified as satisfactory in 46 cases, better in 23 cases and unsatisfactory in 12 cases. The maximum outer diameters of small bowel in different segments were 24 mm ± 4.5 mm at duodenum, 24 mm ±3.9 mm at jejunum and 23 mm ±3.3 mm at ileum respectively. The length and superposition of small intestine were classified as dense-type in 7 cases, uniformity-type in 58

  15. Vascular Structure Identification in Intraoperative 3D Contrast-Enhanced Ultrasound Data

    Directory of Open Access Journals (Sweden)

    Elisee Ilunga-Mbuyamba

    2016-04-01

    Full Text Available In this paper, a method of vascular structure identification in intraoperative 3D Contrast-Enhanced Ultrasound (CEUS data is presented. Ultrasound imaging is commonly used in brain tumor surgery to investigate in real time the current status of cerebral structures. The use of an ultrasound contrast agent enables to highlight tumor tissue, but also surrounding blood vessels. However, these structures can be used as landmarks to estimate and correct the brain shift. This work proposes an alternative method for extracting small vascular segments close to the tumor as landmark. The patient image dataset involved in brain tumor operations includes preoperative contrast T1MR (cT1MR data and 3D intraoperative contrast enhanced ultrasound data acquired before (3D-iCEUS s t a r t and after (3D-iCEUS e n d tumor resection. Based on rigid registration techniques, a preselected vascular segment in cT1MR is searched in 3D-iCEUS s t a r t and 3D-iCEUS e n d data. The method was validated by using three similarity measures (Normalized Gradient Field, Normalized Mutual Information and Normalized Cross Correlation. Tests were performed on data obtained from ten patients overcoming a brain tumor operation and it succeeded in nine cases. Despite the small size of the vascular structures, the artifacts in the ultrasound images and the brain tissue deformations, blood vessels were successfully identified.

  16. Abdominal and pelvic CT: is positive enteric contrast still necessary? Results of a retrospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kammerer, S.; Hoeink, A.J.; Wessling, J.; Schuelke, C.; Heindel, W.; Buerke, B. [University Hospital Muenster, Department of Clinical Radiology, Muenster (Germany); Heinzow, H. [University Hospital Muenster, Department of Gastroenterology and Metabolic Diseases, Muenster (Germany); Koch, R. [University Muenster, Institute of Biostatistics and Clinical Research, Muenster (Germany)

    2014-10-15

    Evaluation of diagnostic accuracy of abdominal CT depending on the type of enteric contrast agent. Multislice CTs of 2,008 patients with different types of oral preparation (positive with barium, n = 576; neutral with water, n = 716; and no enteric contrast, n = 716) were retrospectively evaluated by two radiologists including delineation of intestinal segments and influence on diagnosis and diagnostic reliability exerted by the enteric contrast, using a three-point scale. Furthermore, diagnostic reliability of the delineation of selected enteric pathologies was noted. CT data were assigned into groups: oncology, inflammation, vascular, pathology, trauma and gastrointestinal pathology. Delineation of the bowel was clearly practicable across all segments irrespective of the type of enteric contrast, though a slight impairment was observed without enteric contrast. Although delineation of intestinal pathologies was mostly classified ''clearly delimitable'' more difficulties occurred without oral contrast (neutral/positive/no contrast, 0.8 %/3.8 %/6.5 %). Compared to examinations without enteric contrast, there was a significant improvement in diagnosis that was even increased regarding the reader's diagnostic reliability. Positive opacification impaired detection of mucosal enhancement or intestinal bleeding. Water can replace positive enteric contrast agents in abdominal CTs. However, selected clinical questions require individual enteric contrast preparations. Pathology detection is noticeably impaired without any enteric contrast. circle Neutral oral contrast ensures an equivalent delineation of the bowel. (orig.)

  17. Dynamic contrast-enhanced MRI versus 18F-FDG PET/CT: Which is better in differentiation between malignant and benign solitary pulmonary nodules?

    Science.gov (United States)

    Feng, Feng; Qiang, Fulin; Shen, Aijun; Shi, Donghui; Fu, Aiyan; Li, Haiming; Zhang, Mingzhu; Xia, Ganlin; Cao, Peng

    2018-02-01

    To prospectively compare the discriminative capacity of dynamic contrast enhanced-magnetic resonance imaging (DCE-MRI) with that of 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in the differentiation of malignant and benign solitary pulmonary nodules (SPNs). Forty-nine patients with SPNs were included in this prospective study. Thirty-two of the patients had malignant SPNs, while the other 17 had benign SPNs. All these patients underwent DCE-MRI and 18 F-FDG PET/CT examinations. The quantitative MRI pharmacokinetic parameters, including the trans-endothelial transfer constant (K trans ), redistribution rate constant (K ep ), and fractional volume (V e ), were calculated using the Extended-Tofts Linear two-compartment model. The 18 F-FDG PET/CT parameter, maximum standardized uptake value (SUV max ), was also measured. Spearman's correlations were calculated between the MRI pharmacokinetic parameters and the SUV max of each SPN. These parameters were statistically compared between the malignant and benign nodules. Receiver operating characteristic (ROC) analyses were used to compare the diagnostic capability between the DCE-MRI and 18 F-FDG PET/CT indexes. Positive correlations were found between K trans and SUV max , and between K ep and SUV max (P0.05). DCE-MRI can be used to differentiate between benign and malignant SPNs and has the advantage of being radiation free.

  18. Dynamic contrast-enhanced MRI versus 18F-FDG PET/CT: Which is better in differentiation between malignant and benign solitary pulmonary nodules?

    Science.gov (United States)

    Feng, Feng; Qiang, Fulin; Shen, Aijun; Shi, Donghui; Fu, Aiyan; Li, Haiming; Zhang, Mingzhu; Xia, Ganlin; Cao, Peng

    2018-01-01

    Objective To prospectively compare the discriminative capacity of dynamic contrast enhanced-magnetic resonance imaging (DCE-MRI) with that of 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in the differentiation of malignant and benign solitary pulmonary nodules (SPNs). Methods Forty-nine patients with SPNs were included in this prospective study. Thirty-two of the patients had malignant SPNs, while the other 17 had benign SPNs. All these patients underwent DCE-MRI and 18F-FDG PET/CT examinations. The quantitative MRI pharmacokinetic parameters, including the trans-endothelial transfer constant (Ktrans), redistribution rate constant (Kep), and fractional volume (Ve), were calculated using the Extended-Tofts Linear two-compartment model. The 18F-FDG PET/CT parameter, maximum standardized uptake value (SUVmax), was also measured. Spearman’s correlations were calculated between the MRI pharmacokinetic parameters and the SUVmax of each SPN. These parameters were statistically compared between the malignant and benign nodules. Receiver operating characteristic (ROC) analyses were used to compare the diagnostic capability between the DCE-MRI and 18F-FDG PET/CT indexes. Results Positive correlations were found between Ktrans and SUVmax, and between Kep and SUVmax (P0.05). Conclusions DCE-MRI can be used to differentiate between benign and malignant SPNs and has the advantage of being radiation free. PMID:29545716

  19. Using 80 kVp on a 320-row scanner for hepatic multiphasic CT reduces the contrast dose by 50 % in patients at risk for contrast-induced nephropathy

    Energy Technology Data Exchange (ETDEWEB)

    Taguchi, Narumi; Oda, Seitaro; Utsunomiya, Daisuke; Nakaura, Takeshi; Imuta, Masanori; Yamamura, Sadahiro; Yuki, Hideaki; Kidoh, Masafumi; Hirata, Kenichiro; Namimoto, Tomohiro; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto (Japan); Funama, Yoshinori [Kumamoto University, Department of Medical Physics, Faculty of Life Sciences, Kumamoto (Japan); Hatemura, Masahiro; Kai, Noriyuki [Kumamoto University Hospital, Department of Central Radiology, Kumamoto (Japan)

    2017-02-15

    We evaluated the effects of a low contrast material (CM) dose protocol using 80-kVp on the image quality of hepatic multiphasic CT scans acquired on a 320-row CT scanner. We scanned 30 patients with renal insufficiency (eGFR < 45 mL/min/1.73 m{sup 2}) using 80-kVp and a CM dose of 300mgI/kg. Another 30 patients without renal insufficiency (eGFR > 60 mL/min/1.73 m{sup 2}) were scanned with the conventional 120-kVp protocol and the standard CM dose of 600mgI/kg. Quantitative image quality parameters, i.e. CT attenuation, image noise, and the contrast-to-noise ratio (CNR) were compared and the visual image quality was scored on a four-point scale. The volume CT dose index (CTDI{sub vol}) and the size-specific dose estimate (SSDE) recorded with the 80- and the 120-kVp protocols were also compared. Image noise and contrast enhancement were equivalent for the two protocols. There was no significant difference in the CNR of all anatomic sites and in the visual scores for overall image quality. The CTDI{sub vol} and SSDE were approximately 25-30 % lower under the 80-kVp protocol. Hepatic multiphase CT using 80-kVp on a 320-row CT scanner allowed for a decrease in the CM dose and a reduction in the radiation dose without image quality degradation in patients with renal insufficiency. (orig.)

  20. Neoadjuvant chemotherapy in breast cancer: prediction of pathologic response with PET/CT and dynamic contrast-enhanced MR imaging--prospective assessment.

    Science.gov (United States)

    Tateishi, Ukihide; Miyake, Mototaka; Nagaoka, Tomoaki; Terauchi, Takashi; Kubota, Kazunori; Kinoshita, Takayuki; Daisaki, Hiromitsu; Macapinlac, Homer A

    2012-04-01

    To clarify whether fluorine 18 ((18)F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging performed after two cycles of neoadjuvant chemotherapy (NAC) can be used to predict pathologic response in breast cancer. Institutional human research committee approval and written informed consent were obtained. Accuracy after two cycles of NAC for predicting pathologic complete response (pCR) was examined in 142 women (mean age, 57 years: range, 43-72 years) with histologically proved breast cancer between December 2005 and February 2009. Quantitative PET/CT and DCE MR imaging were performed at baseline and after two cycles of NAC. Parameters of PET/CT and of blood flow and microvascular permeability at DCE MR were compared with pathologic response. Patients were also evaluated after NAC by using Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 based on DCE MR measurements and European Organization for Research and Treatment of Cancer (EORTC) criteria and PET Response Criteria in Solid Tumors (PERCIST) 1.0 based on PET/CT measurements. Multiple logistic regression analyses were performed to examine continuous variables at PET/CT and DCE MR to predict pCR, and diagnostic accuracies were compared with the McNemar test. Significant decrease from baseline of all parameters at PET/CT and DCE MR was observed after NAC. Therapeutic response was obtained in 24 patients (17%) with pCR and 118 (83%) without pCR. Sensitivity, specificity, and accuracy to predict pCR were 45.5%, 85.5%, and 82.4%, respectively, with RECIST and 70.4%, 95.7%, and 90.8%, respectively, with EORTC and PERCIST. Multiple logistic regression revealed three significant independent predictors of pCR: percentage maximum standardized uptake value (%SUV(max)) (odds ratio [OR], 1.22; 95% confidence interval [CI]: 1.11, 1.34; P PET/CT is superior to DCE MR for the prediction of pCR (%SUV(max) [90.1%] vs %κ

  1. Role of 18F-FDG PET/CT in diagnosing peritoneal carcinomatosis in the restaging of patient with ovarian cancer as compared to contrast enhanced CT and tumor marker Ca-125.

    Science.gov (United States)

    Rubini, G; Altini, C; Notaristefano, A; Merenda, N; Rubini, D; Ianora, A A Stabile; Asabella, A Niccoli

    2014-01-01

    To investigate the role of whole-body fluorine-18-2-deoxy-2-fluoro-d-glucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) in the identification of peritoneal carcinomatosis in patients with ovarian cancer (OC). Seventy-nine patients with histologically proven stages III-IV OC who underwent (18)F-FDG PET/CT were studied retrospectively. We considered group A as 51 patients who also underwent computed-tomography with contrast-enhancement (CECT), and group B as 35 patients who had also been tested for biomarker Ca-125. Sensitivity, specificity, accuracy, positive predictive values (PPV) and negative predictive values (NPV) of (18)F-FDG PET/CT as compared to CECT and to Ca-125 were evaluated. (18)F-FDG PET/CT' sensitivity, specificity, accuracy, PPV and NPV for all 79 patients were: 85%, 92.31%, 88.61%, 91.89% and 85.71%, respectively. (18)F-FDG PET/CT sensitivity in group A was 78.6%, while it was 53.6% for CECT. (18)F-FDG PET/CT specificity, calculated in the same group, was 91.3%, while that of CECT was 60.9% (statistically significant difference, McNemar 4, P=0.039). Accuracy was 84.3% and 56.9%, respectively. (18)F-FDG PET/CT' sensitivity in group B was 86.4%, while that of Ca-125 was 81.8% (no statistical difference, McNemar 0, P=1). (18)F-FDG PET/CT specificity in group B was 84.6% while that of Ca-125 was 38.5% (clear but not statistically significant difference, McNemar 3.12, P=0.070). Accuracy calculated in the same group was 85.7% for (18)F-FDG PET/CT and 65.7% for Ca-125. (18)F-FDG PET/CT is a useful diagnostic tool when peritoneal biopsy cannot be performed and it can better select those who are candidates for adjuvant chemotherapy. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  2. Visualizing Typical Features of Breast Fibroadenomas Using Phase-Contrast CT: An Ex-Vivo Study

    Science.gov (United States)

    Grandl, Susanne; Willner, Marian; Herzen, Julia; Sztrókay-Gaul, Anikó; Mayr, Doris; Auweter, Sigrid D.; Hipp, Alexander; Birnbacher, Lorenz; Marschner, Mathias; Chabior, Michael; Reiser, Maximilian; Pfeiffer, Franz; Bamberg, Fabian; Hellerhoff, Karin

    2014-01-01

    Background Fibroadenoma is the most common benign solid breast lesion type and a very common cause for histologic assessment. To justify a conservative therapy, a highly specific discrimination between fibroadenomas and other breast lesions is crucial. Phase-contrast imaging offers improved soft-tissue contrast and differentiability of fine structures combined with the potential of 3-dimensional imaging. In this study we assessed the potential of grating-based phase-contrast CT imaging for visualizing diagnostically relevant features of fibroadenomas. Materials and Methods Grating-based phase-contrast CT was performed on six ex-vivo formalin-fixed breast specimens containing a fibroadenoma and three samples containing benign changes that resemble fibroadenomas using Talbot Lau interferometry and a polychromatic X-ray source. Phase-contrast and simultaneously acquired absorption-based 3D-datasets were manually matched with corresponding histological slices. The visibility of diagnostically valuable features was assessed in comparison with histology as the gold-standard. Results In all cases, matching of grating-based phase-contrast CT images and histology was successfully completed. Grating-based phase-contrast CT showed greatly improved differentiation of fine structures and provided accurate depiction of strands of fibrous tissue within the fibroadenomas as well as of the diagnostically valuable dilated, branched ductuli of the fibroadenomas. A clear demarcation of tumor boundaries in all cases was provided by phase- but not absorption-contrast CT. Conclusions Pending successful translation of the technology to a clinical setting and considerable reduction of the required dose, the data presented here suggest that grating-based phase-contrast CT may be used as a supplementary non-invasive diagnostic tool in breast diagnostics. Phase-contrast CT may thus contribute to the reduction of false positive findings and reduce the recall and core biopsy rate in population

  3. Clinical evaluation of contrast-enhanced digital mammography and contrast enhanced tomosynthesis--Comparison to contrast-enhanced breast MRI.

    Science.gov (United States)

    Chou, Chen-Pin; Lewin, John M; Chiang, Chia-Ling; Hung, Bao-Hui; Yang, Tsung-Lung; Huang, Jer-Shyung; Liao, Jia-Bin; Pan, Huay-Ben

    2015-12-01

    To compare the diagnostic accuracy of contrast-enhanced digital mammography (CEDM) and contrast-enhanced tomosynthesis (CET) to dynamic contrast enhanced breast MRI (DCE-MRI) using a multireader-multicase study. Institutional review board approval and informed consents were obtained. Total 185 patients (mean age 51.3) with BI-RADS 4 or 5 lesions were evaluated before biopsy with mammography, tomosynthesis, CEDM, CET and DCE-MRI. Mediolateral-oblique and cranio-caudal views of the target breast CEDM and CET were acquired at 2 and 4 min after contrast agent injection. A mediolateral-oblique view of the non-target breast was taken at 6 min. Each lesion was scored with forced BI-RADS categories by three readers. Each reader interpreted lesions in the following order: mammography, tomosynthesis, CEDM, CET, and DCE-MRI during a single reading session. Histology showed 81 cancers and 144 benign lesions in the study. Of the 81 malignant lesions, 44% (36/81) were invasive and 56% (45/81) were non-invasive. Areas under the ROC curve, averaged for the 3 readers, were as follows: 0.897 for DCE-MRI, 0.892 for CET, 0.878 for CEDM, 0.784 for tomosynthesis and 0.740 for mammography. Significant differences in AUC were found between the group of contrast enhanced modalities (CEDM, CET, DCE-MRI) and the unenhanced modalities (all p0.05). CET and CEDM may be considered as an alternative modality to MRI for following up women with abnormal mammography. All three contrast modalities were superior in accuracy to conventional digital mammography with or without tomosynthesis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Contrast-enhanced computed tomography of the primary tumor in muscle invasive carcinoma of the urinary bladder

    International Nuclear Information System (INIS)

    Sager, E.M.

    1991-01-01

    Patients with muscle invasive carcinoma of the urinary bladder were examined with contrast-enhanced CT of the primary tumor. A specially designed technique was developed to increase the diagnostic potential of CT. The most important points about the technique were controlled filling of the bladder, the use of thin slices, series of scans before and after intravenous injection of contrast medium, and long scanning times in the precontrast series. The absorbed dose to the patient resulting from the new technique was found to be within the range of the dose from urography or barium enema. This dose was considered to be acceptable given the diagnostic gain of the procedure. Features of irradiated bladder tumors were analysed to find which parameter correlated with persistent malignancy. High contrast enhancement of a tumor relative to the bladder wall was found to be the best indicator of a malignant tumour after irradiation. 127 refs

  5. A prospective study about an imaging quality of low dosage of contrast media with single-detector CT

    International Nuclear Information System (INIS)

    Saku, Madoka

    2004-01-01

    The steadily elevating cost of the contrast-enhanced CT has been a problem in last decade. One approach to curtail the cost is to reduce the amount of contrast media (CM). The purpose of this study was to examine the possibility of reducing the volume of CM in single-detector CT (SDCT) without compromising diagnostic ability. One hundred ml of Iohexol 300 and 75 ml of Ioversol 320 were compared in a prospective CT study about their imaging quality. One hundred patients were randomly divided into two parallel groups (A and B). The former agent was used for group A and the latter for B. CT attenuations of the aorta, central vein, spleen and kidney were measured and each imaging quality was reviewed by three radiologists. CT attenuations and the imaging quality were significantly superior (p<0.05) in A group, however, comparing in the condition under 50 kg patients, they showed no significant differences and the quality was tolerable for diagnosis in both group. This demonstrates the difficulty to perform the high-quality CT with a reduced CM in SDCT. However, this does not negate the diagnostic ability of low dose of CM, but reflects the importance of determining the acceptable lowest doze of CM for diagnosis. (author)

  6. Patterns of appearance and risk of misdiagnosis of intrahepatic cholangiocarcinoma in cirrhosis at contrast enhanced ultrasound.

    Science.gov (United States)

    Galassi, Marzia; Iavarone, Massimo; Rossi, Sandro; Bota, Simona; Vavassori, Sara; Rosa, Laura; Leoni, Simona; Venerandi, Laura; Marinelli, Sara; Sangiovanni, Angelo; Veronese, Letizia; Fraquelli, Mirella; Granito, Alessandro; Golfieri, Rita; Colombo, Massimo; Bolondi, Luigi; Piscaglia, Fabio

    2013-05-01

    Primary aim was to validate the percentage of intrahepatic cholangiocarcinomas (ICC) which have a contrast vascular pattern at contrast enhanced ultrasound (CEUS) at risk of misdiagnosis with hepatocellular carcinoma (HCC) and, secondary aim, to verify if any characteristics in the CEUS pattern helps to identify ICC. All ICC on cirrhosis seen in three Italian centres (Bologna, Milan and Pavia) between 2003 and 2011, in which CEUS and at least another imaging technique (CT or MRI) had been performed, were retrospectively identified. Those patients with ICC size comparable to the early HCC stage (Milan criteria, considered as small ICC) were enrolled for this study. The enhancement pattern at CEUS was analysed and compared with CT or MRI. A total of 25 small ICC made this study group. CEUS was at risk of misdiagnosis of ICC for HCC in a significantly higher number of cases than in CT (performed in 24 ICC) (52% vs. 4.2%, P = 0.009) and MRI (11 ICC) (52% vs. 9.1%, P = 0.02). A different contrast pattern among all techniques was found in 6 of 10 ICC lesions submitted to the three imaging methods. In the arterial phase, ICC lacked global hyperenhacement in approximately 50% of cases at CEUS and the degree of intensity of wash-out in the late phase was marked in 24% of nodules. CEUS misdiagnosed as HCC a significantly higher number of ICC lesions in cirrhotic patients than CT and MRI. However, some CEUS contrast features can help suspect ICC, especially in some cases with inconclusive CT or MRI. © 2013 John Wiley & Sons A/S.

  7. Preliminary study of the scan-delay-time during the combined examation of CT perfusion and CT angiography after contrast media administration in cerebral and cervical CT angiography

    International Nuclear Information System (INIS)

    Cai Wu; Gong Jianping; Zhu Jiangtao; Qiao Fang; Chen Guangqiang; Zhang Bo; Yi Bixing; Qian Minghui

    2010-01-01

    Objective: To discuss the feasibility of the time to peak of cerebral CT perfusion (CTP) in predicting the scan-delay-time after contrast media administration in cerebral and cervical CT angiography (CTA). Methods: Retrospective Analysis was performed in eighty patients who had been examined with cerebral and cervical CTA, they were divided randomly into two groups. Group A:40 patients were performed by the method of experience of 20 seconds as scan-delay-time. Group B:the other 40 patients were examined with the combination scanning technology of CTP-CTA. They were all measured with enhancement value of CT in the M1 segment of left middle cerebral artery, superior sagittal sinus , left common carotid artery adjacent to the fourth cervical vertebrace and internal jugular vein, and then calculate the difference between the arterys and the veins in the same layer. Statistical significance was determined with t test. Results: (1)The enhancement value of CT in the cerebral and cervical artery vessels and the resolving power between the arterys and the veins in the same layer of group B were higher than that in group A. (2) Group B whose cerebral and cervical artery vessels rescontructed from the raw CT data set showed clearly; There were an advance in 3 cases (7.5%), a delay in 5 cases (12.5%) in group A whose cerebral and cervical artery vessels rescontructed from the raw CT data set didn't show clearly.Conclusion It's a satisfactory method based on successful cerebral and cervical CTA study to take the time to peak in CT perfusion as the scan-delay-time during the combined examination of CTP and CTA with 64-detector spiral CT. (authors)

  8. Prevalence of latent and manifest hyperthyroidism in an iodine-deficient area: non-selected patient population admitted for CT studies with iodine-containing contrast agents

    International Nuclear Information System (INIS)

    Saam, T.; Hess, T.; Kasperk, C.; Kauffmann, G.W.; Duex, M.

    2005-01-01

    Purpose: to evaluate the prevalence of latent and manifest hyperthyroidism in a non-selected group of patients admitted for contrast enhanced CT studies blood samples were tested for the levels of thyroid-stimulating hormone (TSH). Material and methods: TSH blood levels were obtained in 548 consecutive patients who were scheduled for contrast-enhanced (Iopromide; 300 mg iodine/ml) CT scanning. In case of TSH levels registered (sodium perchlorate) was commenced before scanning. In case of TSH levels < 0.1 mU/l, CT scanning was not performed but further evaluation of the thyroid function was initiated. Results: TSH blood levels ranged from 0.4 to 7.5 mU/l in 512 patients, and 36 patients (6.6%) had TSH blood levels < 0.4 mU/l and 9 patients blood levels < 0.1 mU/l, with 32 of those patients (5.8%) having regular T3 and T4 blood levels consistent with latent hyperthyroidism. In 4 patients (0.8%), T3 or T4 blood levels were increased consistent with manifest hyperthyroidism. Conclusion: in South Germany, the prevalence of latent or manifest hyperthyroidism in a non-selected patient group is high. Therefore TSH blood levels should be obtained prior to contrast-enhanced CT studies. (orig.)

  9. Fluctuations in eGFR in relation to unenhanced and enhanced MRI and CT outpatients

    DEFF Research Database (Denmark)

    Azzouz, Manal; Rømsing, Janne; Thomsen, Henrik S

    2014-01-01

    OBJECTIVE: To study fluctuations in estimated glomerular filtration rate (eGFR) in relation to contrast medium (CM) enhanced magnetic resonance imaging (MRI) and computed tomography (CT) compared to control groups in outpatients. MATERIALS AND METHODS: eGFR was determined right before the imaging......-induced nephropathy (CIN) requirement when the definition s-creatinine ≥44μmol/l (0.5mg/dl) was used. CONCLUSIONS: eGFR in outpatients undergoing MRI or CT did vary independently of whether the patient received contrast or not. The findings probably reflect the natural variations in s-creatinine levels. This should...

  10. Usefulness of low dose oral contrast media in 18F-FDG PET/CT

    International Nuclear Information System (INIS)

    An, Young Sil; Yoon, Joon Kee; Hong, Seon Pyo; Joh, Chul Woo; Yoon, Seok Nam

    2006-01-01

    The standard protocol using large volume of oral contrast media may cause gastrointestinal discomfort and contrast-related artifacts in PET/CT. The aim of this study was to evaluate the usefulness of low dose oral contrast in 18 F-FDG PET/CT. We retrospectively reviewed the whole-body PET/CT images in a total of 435 patients. About 200 ml of oral contrast agent (barium sulfate) was administered immediately before injection of 18 F-FDG. The FDG uptake of intestines was analyzed by visual and semi-quantitative method on transaxial, coronal and saggital planes. Seventy (16%, 113 sites) of 435 images showed high FDG uptake (peak SUV > 4); 50 (74%, 84 sites) with diffuse and 20 (26%, 29 sites) with focal uptake. The most commonly delivered site of oral contrast media was small bowel (n = 27, 39%). On PET/CT images, FDG uptake coexisted with oral contrast media in 26 patients (54%, 38 sites) with diffuse pattern and 9 (45%, 9 sites) with focal pattern, and by sites, those were 38 (45%) and 9 (31%), respectively. In small bowel regions, the proportion of coexistence reached as high as 61% (29/47 sites). A visual analysis of available non-attenuation corrected PET images of 27 matched regions revealed no contrast-related artifact. We concluded that the application of low dose contrast media could be helpful in the evaluation of abdominal uptake in the FDG PET/CT image

  11. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    International Nuclear Information System (INIS)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun; Kim, Tae Kyoung; Khalili, Korosh; Bae, Mi Hyun; Lee, Joo Yeon; Lee, Sung-Gyu; Yu, Eun Sil

    2010-01-01

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ( pre L-S) and contrast-enhanced ( post L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ( post L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for pre L-S, post L-S and post L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of pre L-S and post L-S did not differ (P ≥ 0.054), despite a trend towards a lower accuracy with post L-S. post L-B yielded higher accuracy than pre L-S at threshold levels of 5% and 10% (P ≤ 0.002) and similar accuracy to pre L-S at the other threshold levels (P ≥ 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  12. Deep Learning with Convolutional Neural Network for Differentiation of Liver Masses at Dynamic Contrast-enhanced CT: A Preliminary Study.

    Science.gov (United States)

    Yasaka, Koichiro; Akai, Hiroyuki; Abe, Osamu; Kiryu, Shigeru

    2018-03-01

    Purpose To investigate diagnostic performance by using a deep learning method with a convolutional neural network (CNN) for the differentiation of liver masses at dynamic contrast agent-enhanced computed tomography (CT). Materials and Methods This clinical retrospective study used CT image sets of liver masses over three phases (noncontrast-agent enhanced, arterial, and delayed). Masses were diagnosed according to five categories (category A, classic hepatocellular carcinomas [HCCs]; category B, malignant liver tumors other than classic and early HCCs; category C, indeterminate masses or mass-like lesions [including early HCCs and dysplastic nodules] and rare benign liver masses other than hemangiomas and cysts; category D, hemangiomas; and category E, cysts). Supervised training was performed by using 55 536 image sets obtained in 2013 (from 460 patients, 1068 sets were obtained and they were augmented by a factor of 52 [rotated, parallel-shifted, strongly enlarged, and noise-added images were generated from the original images]). The CNN was composed of six convolutional, three maximum pooling, and three fully connected layers. The CNN was tested with 100 liver mass image sets obtained in 2016 (74 men and 26 women; mean age, 66.4 years ± 10.6 [standard deviation]; mean mass size, 26.9 mm ± 25.9; 21, nine, 35, 20, and 15 liver masses for categories A, B, C, D, and E, respectively). Training and testing were performed five times. Accuracy for categorizing liver masses with CNN model and the area under receiver operating characteristic curve for differentiating categories A-B versus categories C-E were calculated. Results Median accuracy of differential diagnosis of liver masses for test data were 0.84. Median area under the receiver operating characteristic curve for differentiating categories A-B from C-E was 0.92. Conclusion Deep learning with CNN showed high diagnostic performance in differentiation of liver masses at dynamic CT. © RSNA, 2017 Online

  13. Contrast opacification for CT from iodine, gadolinium and ytterbium

    International Nuclear Information System (INIS)

    Zwicker, C.; Langer, M.; Ullrich, V.; Felix, R.

    1993-01-01

    The absorption of the elements iodine, gadolinium und ytterbium in various dilutions was studied in relation to CT. Regression analysis and specific CT density measurements showed that absorption decreases from gadolinium to ytterbium and iodine. These results were confirmed by experiments using ten dogs. Boli of 0.5 molar gadolinium used for angio-CT without table movement showed the largest increase in density in the aorta and liver with an average of 190 HU and 21 HU respectively compared with iodine which gave 157 HU and 12 HU respectively. The animal experimental studies suggest that gadolinium and ytterbium are suitable contrast media for dynamic CT investigations. (orig.) [de

  14. Automated extraction of metastatic liver cancer regions from abdominal contrast CT images

    International Nuclear Information System (INIS)

    Yamakawa, Junki; Matsubara, Hiroaki; Kimura, Shouta; Hasegawa, Junichi; Shinozaki, Kenji; Nawano, Shigeru

    2010-01-01

    In this paper, automated extraction of metastatic liver cancer regions from abdominal contrast X-ray CT images is investigated. Because even in Japan, cases of metastatic liver cancers are increased due to recent Europeanization and/or Americanization of Japanese eating habits, development of a system for computer aided diagnosis of them is strongly expected. Our automated extraction procedure consists of following four steps; liver region extraction, density transformation for enhancement of cancer regions, segmentation for obtaining candidate cancer regions, and reduction of false positives by shape feature. Parameter values used in each step of the procedure are decided based on density and shape features of typical metastatic liver cancers. In experiments using practical 20 cases of metastatic liver tumors, it is shown that 56% of true cancers can be detected successfully from CT images by the proposed procedure. (author)

  15. Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: A systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Connolly, Michael J.; McInnes, Matthew D.F.; Schieda, Nicola [University of Ottawa Department of Radiology, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, ON (United States); El-Khodary, Mohamed [McMaster University Department of Radiology, Hamilton, ON (Canada); McGrath, Trevor A. [University of Ottawa, Faculty of Medicine, Ottawa, Ontario (Canada)

    2017-10-15

    To compare the diagnostic accuracy of dual-energy (DE) virtual non-contrast computed tomography (vNCT) to non-contrast CT (NCT) for the diagnosis of adrenal adenomas. Search of multiple databases and grey literature was performed. Two reviewers independently applied inclusion criteria and extracted data. Risk of bias was assessed using QUADAS-2. Summary estimates of diagnostic accuracy were generated and sources of heterogeneity were assessed. Five studies (170 patients; 192 adrenal masses) were included for diagnostic accuracy assessment; all used dual-source dual-energy CT. Pooled sensitivity for adrenal adenoma on vNCT was 54% (95% CI: 47-62%). Pooled sensitivity for NCT was 57% (95% CI: 45-69%). Pooling of specificity was not performed since no false positives were reported. There was a trend for overestimation of HU density on vNCT as compared to NCT which appeared related to contrast timing. Potential sources of bias were seen regarding the index test and reference standard for the included studies. Potential sources of heterogeneity between studies were seen in adenoma prevalence and intravenous contrast timing. vNCT images generated from dual-energy CT demonstrated comparable sensitivity to NCT for the diagnosis of adenomas; however the included studies are heterogeneous and at high risk for some types of bias. (orig.)

  16. Recurrent postoperative sciatica: Evaluation with MR imaging and enhanced CT

    International Nuclear Information System (INIS)

    Duvauferrier, R.; Frocain, L.; Husson, J.L.

    1987-01-01

    The authors prospectively compared MR imaging performed with a surface coil and CT performed with iodinated contrast agent enhancement in 50 patients with recurrent postoperative sciatica. Surgical decision was an objective measure of accuracy. Surgical treatment was selected for 27 patients. All 27 underwent MR imaging. The 15 patients who underwent CT/surgical treatment were included in the 27 indications of SCMR. All predictions based on MR imaging findings were confirmed at surgery. There were 25 recurrent disk herniations, including five with scar tissue, and two disk herniations above or below the level of the diskectomy. In the 12 patients with scar tissue detected on CT there were seven recurrent disk hernitions, four recurrent disk herniations with scar tissue, and one disk herniation below the level of the diskectomy

  17. The role of routine preoperative EUS when performed after contrast enhanced CT in the diagnostic work-up in patients suspected of pancreatic or periampullary cancer.

    Science.gov (United States)

    Cieslak, Kasia P; van Santvoort, Hjalmar C; Vleggaar, Frank P; van Leeuwen, Maarten S; ten Kate, Fibo J; Besselink, Marc G; Molenaar, I Quintus

    2014-01-01

    In patients suspected of pancreatic or periampullary cancer, abdominal contrast-enhanced computed tomography (CT) is the standard diagnostic modality. A supplementary endoscopic ultrasonography (EUS) is often performed, although there is only limited evidence of its additional diagnostic value. The aim of the study is to evaluate the additional diagnostic value of EUS over CT in deciding on exploratory laparotomy in patients suspected of pancreatic or periampullary cancer. We retrospectively analyzed 86 consecutive patients who routinely underwent CT and EUS before exploratory laparotomy with or without pancreatoduodenectomy for suspected pancreatic or periampullary carcinoma between 2007 and 2010. Primary outcomes were visibility of a mass, resectability on CT/EUS and resection with curative intent. A mass was visible on CT in 72/86 (84%) patients. In these 72 patients, EUS demonstrated a mass in 64/72 (89%) patients. Resectability was accurately predicted by CT in 65/72 (90%) and by EUS in 58/72 (81%) patients. In 14/86 (16%) patients no mass was seen on CT. EUS showed a mass in 12/14 (86%) of these patients. A malignant lesion was histological proven in 11/12 (92%) of these patients. Overall, resectability was accurately predicted by CT and EUS in 90% (77/86) and 84% (72/86), respectively. In patients with a visible mass on CT, suspected for pancreatic or periampullary cancer, EUS has no additional diagnostic value, does not influence the decision to perform laparotomy and should therefore not be performed routinely. In patients without a visible mass on CT, EUS is useful to confirm the presence of a tumor. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  18. Contrast enhancement pattern on multidetector CT predicts malignancy in pancreatic endocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Cappelli, Carla [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Azienda Ospedaliero-Universitaria Pisana-Radiodiagnostica I, Pisa (Italy); Boggi, Ugo [University of Pisa, General and Transplant Surgery, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Mazzeo, Salvatore; Cervelli, Rosa; Contillo, Benedetta Pontillo; Bartolozzi, Carlo [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Campani, Daniela; Funel, Niccola [University of Pisa, Pathology, Department of Surgical, Medical, Molecular and Critical Area Pathology, Pisa (Italy)

    2014-12-02

    Preoperative suspicion of malignancy in pancreatic neuroendocrine tumours (pNETs) is mostly based on tumour size. We retrospectively reviewed the contrast enhancement pattern (CEP) of a series of pNETs on multiphasic multidetector computed tomography (MDCT), to identify further imaging features predictive of lesion aggressiveness. Sixty pNETs, diagnosed in 52 patients, were classified based on CEP as: type A showing early contrast enhancement and rapid wash-out; type B presenting even (B1) or only (B2) late enhancement. All tumours were resected allowing pathologic correlations. Nineteen pNETs showed type A CEP (5-20 mm), 29 type B1 CEP (5-80 mm) and 12 type B2 (15-100 mm). All tumours were classified as well differentiated tumours, 19 were benign (WDt-b), 15 with uncertain behaviour (WDt-u) and 26 carcinomas (WDC). None of A lesions were malignant (12 WDt-b; 7 WDt-u), all B2 lesions were WDC, 7 B1 lesions were WDt-b, 8 WDt-u and 14 WDC; 4/34 (12 %) lesions ≤2cm were WDC. CEP showed correlation with all histological prognostic indicators. Correlating with the lesion grading and other histological prognostic predictors, CEP may preoperatively suggest the behaviour of pNETs, assisting decisions about treatment. Moreover CEP allows recognition of malignant small tumours, incorrectly classified on the basis of their dimension. (orig.)

  19. Contrast enhancement pattern on multidetector CT predicts malignancy in pancreatic endocrine tumours

    International Nuclear Information System (INIS)

    Cappelli, Carla; Boggi, Ugo; Mazzeo, Salvatore; Cervelli, Rosa; Contillo, Benedetta Pontillo; Bartolozzi, Carlo; Campani, Daniela; Funel, Niccola

    2015-01-01

    Preoperative suspicion of malignancy in pancreatic neuroendocrine tumours (pNETs) is mostly based on tumour size. We retrospectively reviewed the contrast enhancement pattern (CEP) of a series of pNETs on multiphasic multidetector computed tomography (MDCT), to identify further imaging features predictive of lesion aggressiveness. Sixty pNETs, diagnosed in 52 patients, were classified based on CEP as: type A showing early contrast enhancement and rapid wash-out; type B presenting even (B1) or only (B2) late enhancement. All tumours were resected allowing pathologic correlations. Nineteen pNETs showed type A CEP (5-20 mm), 29 type B1 CEP (5-80 mm) and 12 type B2 (15-100 mm). All tumours were classified as well differentiated tumours, 19 were benign (WDt-b), 15 with uncertain behaviour (WDt-u) and 26 carcinomas (WDC). None of A lesions were malignant (12 WDt-b; 7 WDt-u), all B2 lesions were WDC, 7 B1 lesions were WDt-b, 8 WDt-u and 14 WDC; 4/34 (12 %) lesions ≤2cm were WDC. CEP showed correlation with all histological prognostic indicators. Correlating with the lesion grading and other histological prognostic predictors, CEP may preoperatively suggest the behaviour of pNETs, assisting decisions about treatment. Moreover CEP allows recognition of malignant small tumours, incorrectly classified on the basis of their dimension. (orig.)

  20. Contrast-enhanced magnetic resonance imaging of tumours of the central nervous systems: a clinical review

    International Nuclear Information System (INIS)

    Graif, M.; Steiner, R.E.

    1986-01-01

    The clinical application of the intravascular paramagnetic contrast agent gadolinium-DTPA for magnetic resonance imaging (MRI) imaging of tumours of the central nervous system (CNS) has been assessed over the past 3 years. Various patterns of contrast enhancement were observed, and situations in MRI where the administration of contrast medium may be useful have been defined. These include lesions which are isointense with normal brain matter, the separation of tumour from surrounding oedema, evaluation of the degree of blood-brain barrier breakdown, delineation of tumours obscured by overlying calcification on computed tomography (CT) and in the investigation of lesions in anatomical areas where CT has known limitations (brain, stem, cervical spine). Changes in relaxation times in normal and abnormal tissues following contrast medium, toxicity and dosage of gadolinium-DTPA, and MRI pulse sequence techniques are reviewed. (author)

  1. Patients with liver FNH and HCC patients with negative AFP: plain and dynamic enhanced MRI and CT findings

    Directory of Open Access Journals (Sweden)

    LI Mingtong

    2015-05-01

    Full Text Available ObjectiveTo investigate plain and dynamic enhanced magnetic resonance imaging (MRI and computed tomography (CT findings in patients with focal nodular hyperplasia (FNH of the liver and hepatocellular carcinoma (HCC patients with negative alpha-fetoprotein (AFP. MethodsA statistical analysis was performed on the clinical data of 124 cases of liver tumor admitted to Beijing Miyun County Hospital from April 2012 to April 2014. ResultsFifty-five of the 74 patients with FNH underwent CT examination, among whom 38 patients received three-phase dynamic enhanced scan and 16 received only plain scan; 62 cases had plain and enhanced MRI with the application of contrast agent Gd-BOPTA in 42 patients. Among the 50 HCC patients with negative AFP, CT examination was performed in 40 and 10 only had plain scan; 46 patients received plain and enhanced MRI with the use of contrast agent Gd-BOPTA in 30. Delayed scan after 1-2 h demonstrated low signal in 30 lesions of the 30 cases. ConclusionFor patients with liver FNH and AFP-negative HCC patients, their plain and dynamic enhanced MRI and CT scan have respective characteristics. A combination of multiple examination methods can significantly improve diagnostic yield of the two diseases.

  2. Contrast-enhanced turbo spin-echo(TSE) T1-weighted imaging: improved contrast of enhancing lesions

    International Nuclear Information System (INIS)

    Choi, Sung Wook; Lee, Ghi Jai; Shim, Jae Chan; Lee, Young Ju; Jeong, Se Hyung; Kim, Ho kyun

    1997-01-01

    The purpose of this study was to evaluate the effect of contrast improvement of enhancing brain lesions by inherent magnetization transfer effect in turbo spin-echo(TSE)T1-weighted MR imaging. Twenty-six enhancing lesions of 19 patients were included in this study. Using a 1.0T superconductive MR unit, contrast-enhanced SE T1-weighted images(TR=3D600 msec, TE=3D12 msec, NEX=3D2, acquistition time=3D4min 27sec) and contrast-enhanced TSE T1-weighted images(TR=3D600 msec, TE=3D12, acquistition time=3D1min 44sec) were obtained. Signal intensities at enhancing lesions and adjacent white matter were measured in the same regions of both images. Signal-to-noise ratio(SNR) of enhancing lesions and adjacent white matter, and con-trast-to-noise ratio(CNR) and lesion-to-background contrast (LBC) of enhancing lesions were calculated and statistically analysed using the paired t-test. On contrast-enhanced TSE T1-weighted images, SNR of enhancing lesions and adjacent white matter decreased by 18%(p<0.01) and 32%(p<0.01), respectively, compared to contrast-enhanced SE T1-weighted images. CNR and LBC of enhancing lesions increased by 16%(p<0.05) and 66%(p<0.01), respectively. Due to the proposed inherent magnetization transfer effects in TSE imaging, con-trast-enhanced T1-weighted TSE images demonstrated a statistically significant improvement in CNR and LBC, compared to conventional contrast-enhanced T1-weighted SE images, and scan time was much shorter

  3. Automatic coronary calcium scoring using noncontrast and contrast CT images

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Guanyu, E-mail: yang.list@seu.edu.cn; Chen, Yang; Shu, Huazhong [Laboratory of Image Science and Technology, School of Computer Science and Engineering, Southeast University, No. 2, Si Pai Lou, Nanjing 210096 (China); Centre de Recherche en Information Biomédicale Sino-Français (LIA CRIBs), Nanjing 210096 (China); Key Laboratory of Computer Network and Information Integration, Southeast University, Ministry of Education, Nanjing 210096 (China); Ning, Xiufang; Sun, Qiaoyu [Laboratory of Image Science and Technology, School of Computer Science and Engineering, Southeast University, No. 2, Si Pai Lou, Nanjing 210096 (China); Key Laboratory of Computer Network and Information Integration, Southeast University, Ministry of Education, Nanjing 210096 (China); Coatrieux, Jean-Louis [INSERM-U1099, Rennes F-35000 (France); Labotatoire Traitement du Signal et de l’Image (LTSI), Université de Rennes 1, Campus de Beaulieu, Bat. 22, Rennes 35042 Cedex (France); Centre de Recherche en Information Biomédicale Sino-Français (LIA CRIBs), Nanjing 210096 (China)

    2016-05-15

    Purpose: Calcium scoring is widely used to assess the risk of coronary heart disease (CHD). Accurate coronary artery calcification detection in noncontrast CT image is a prerequisite step for coronary calcium scoring. Currently, calcified lesions in the coronary arteries are manually identified by radiologists in clinical practice. Thus, in this paper, a fully automatic calcium scoring method was developed to alleviate the work load of the radiologists or cardiologists. Methods: The challenge of automatic coronary calcification detection is to discriminate the calcification in the coronary arteries from the calcification in the other tissues. Since the anatomy of coronary arteries is difficult to be observed in the noncontrast CT images, the contrast CT image of the same patient is used to extract the regions of the aorta, heart, and coronary arteries. Then, a patient-specific region-of-interest (ROI) is generated in the noncontrast CT image according to the segmentation results in the contrast CT image. This patient-specific ROI focuses on the regions in the neighborhood of coronary arteries for calcification detection, which can eliminate the calcifications in the surrounding tissues. A support vector machine classifier is applied finally to refine the results by removing possible image noise. Furthermore, the calcified lesions in the noncontrast images belonging to the different main coronary arteries are identified automatically using the labeling results of the extracted coronary arteries. Results: Forty datasets from four different CT machine vendors were used to evaluate their algorithm, which were provided by the MICCAI 2014 Coronary Calcium Scoring (orCaScore) Challenge. The sensitivity and positive predictive value for the volume of detected calcifications are 0.989 and 0.948. Only one patient out of 40 patients had been assigned to the wrong risk category defined according to Agatston scores (0, 1–100, 101–300, >300) by comparing with the ground

  4. Usefulness of low dose oral contrast media in FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    An, Y. S.; Yun, J. G.; Lee, M. H.; Cho, C. W.; Yun, S. N [Ajou University Medical Center, Suwon (Korea, Republic of)

    2004-07-01

    Oral contrast media might help in interpreting PET/CT images, allowing better discrimination between physiologic and pathologic abdominal uptake. The aim of this study was to evaluate the usefulness of low dose oral contrast on FDG PET/CT. A total of 435 cancer patients received 200mL of oral Barium with water(200mL) immediately before FDG injection. PET images were reconstructed using attenuation correction and iterative reconstruction. The FDG uptake in gastrointestinal(GI) tract were analyzed by visual and semiquantitative method in transaxial, coronal and sagittal planes. Seventy patients(16%, 113 sites) of 435 images showed high FDG uptake(pSUV>4.0) : 50(74%, 84 sites) with diffuse uptake and 20(26%, 29sites) with focal uptake. The most common distribution site of oral contrast media was small bowel (n=27, 39%) and others were small bowel with transverse colon(n=6, 8%), small bowel with ascending and sigmoid colon(n=6, 8%) and etc. In PET/CT images, FDG uptake coexisted with oral contrast was showed in 26 patients(54%) with diffuse pattern and 9(45%) with focal pattern, and by sites, those were 38(45%) and 9(31%), respectively. In small bowel regions, the most common distribution site, the proportion of coexistence reached as high as 61% (29 in the total 47 sites). Application of low dose contrast agent can be helpful in the evaluation of intestinal uptake in FDG PET/CT image.

  5. Usefulness of low dose oral contrast media in FDG PET/CT

    International Nuclear Information System (INIS)

    An, Y. S.; Yun, J. G.; Lee, M. H.; Cho, C. W.; Yun, S. N

    2004-01-01

    Oral contrast media might help in interpreting PET/CT images, allowing better discrimination between physiologic and pathologic abdominal uptake. The aim of this study was to evaluate the usefulness of low dose oral contrast on FDG PET/CT. A total of 435 cancer patients received 200mL of oral Barium with water(200mL) immediately before FDG injection. PET images were reconstructed using attenuation correction and iterative reconstruction. The FDG uptake in gastrointestinal(GI) tract were analyzed by visual and semiquantitative method in transaxial, coronal and sagittal planes. Seventy patients(16%, 113 sites) of 435 images showed high FDG uptake(pSUV>4.0) : 50(74%, 84 sites) with diffuse uptake and 20(26%, 29sites) with focal uptake. The most common distribution site of oral contrast media was small bowel (n=27, 39%) and others were small bowel with transverse colon(n=6, 8%), small bowel with ascending and sigmoid colon(n=6, 8%) and etc. In PET/CT images, FDG uptake coexisted with oral contrast was showed in 26 patients(54%) with diffuse pattern and 9(45%) with focal pattern, and by sites, those were 38(45%) and 9(31%), respectively. In small bowel regions, the most common distribution site, the proportion of coexistence reached as high as 61% (29 in the total 47 sites). Application of low dose contrast agent can be helpful in the evaluation of intestinal uptake in FDG PET/CT image

  6. X-ray phase-contrast CT of a pancreatic ductal adenocarcinoma mouse model.

    Directory of Open Access Journals (Sweden)

    Arne Tapfer

    Full Text Available To explore the potential of grating-based x-ray phase-contrast computed tomography (CT for preclinical research, a genetically engineered mouse model of pancreatic ductal adenocarcinoma (PDAC was investigated. One ex-vivo mouse specimen was scanned with different grating-based phase-contrast CT imaging setups covering two different settings: i high-resolution synchrotron radiation (SR imaging and ii dose-reduced imaging using either synchrotron radiation or a conventional x-ray tube source. These experimental settings were chosen to assess the potential of phase-contrast imaging for two different types of application: i high-performance imaging for virtual microscopy applications and ii biomedical imaging with increased soft-tissue contrast for in-vivo applications. For validation and as a reference, histological slicing and magnetic resonance imaging (MRI were performed on the same mouse specimen. For each x-ray imaging setup, attenuation and phase-contrast images were compared visually with regard to contrast in general, and specifically concerning the recognizability of lesions and cancerous tissue. To quantitatively assess contrast, the contrast-to-noise ratios (CNR of selected regions of interest (ROI in the attenuation images and the phase images were analyzed and compared. It was found that both for virtual microscopy and for in-vivo applications, there is great potential for phase-contrast imaging: in the SR-based benchmarking data, fine details about tissue composition are accessible in the phase images and the visibility of solid tumor tissue under dose-reduced conditions is markedly superior in the phase images. The present study hence demonstrates improved diagnostic value with phase-contrast CT in a mouse model of a complex endogenous cancer, promoting the use and further development of grating-based phase-contrast CT for biomedical imaging applications.

  7. Feasibility of low contrast media volume in CT angiography of the aorta

    International Nuclear Information System (INIS)

    Seehofnerová, Anna; Kok, Madeleine; Mihl, Casper; Douwes, Dave; Sailer, Anni; Nijssen, Estelle; Haan, Michiel J.W. de; Wildberger, Joachim E.; Das, Marco

    2015-01-01

    Using smaller volumes of contrast media (CM) in CT angiography (CTA) is desirable in terms of cost reduction and prevention of contrast-induced nephropathy (CIN). The purpose was to evaluate the feasibility of low CM volume in CTA of the aorta. 77 patients referred for CTA of the aorta were scanned using a standard MDCT protocol at 100 kV. A bolus of 50 ml CM (Iopromide 300 mg Iodine/ml) at a flow rate of 6 ml/s was applied (Iodine delivery rate IDR = 1.8 g/s; Iodine load 15 g) followed by a saline bolus of 40 ml at the same flow rate. Scan delay was determined by the test bolus method. Subjective image quality was assessed and contrast enhancement was measured at 10 anatomical levels of the aorta. Diagnostic quality images were obtained for all patients, reaching a mean overall contrast enhancement of 324 ± 28 HU. Mean attenuation was 350 ± 60 HU at the thoracic aorta and 315 ± 83 HU at the abdominal aorta. A straightforward low volume CM protocol proved to be technically feasible and led to CTA examinations reaching diagnostic image quality of the aorta at 100 kV. Based on these findings, the use of a relatively small CM bolus can be incorporated into routine clinical imaging

  8. Pulmonary nodule characterization: A comparison of conventional with quantitative and visual semi-quantitative analyses using contrast enhancement maps

    International Nuclear Information System (INIS)

    Petkovska, Iva; Shah, Sumit K.; McNitt-Gray, Michael F.; Goldin, Jonathan G.; Brown, Matthew S.; Kim, Hyun J.; Brown, Kathleen; Aberle, Denise R.

    2006-01-01

    Purpose: To determine whether conventional nodule densitometry or analysis based on contrast enhancement maps of indeterminate lung nodules imaged with contrast-enhanced CT can distinguish benign from malignant lung nodules. Materials and method: Thin section, contrast-enhanced CT (baseline, and post-contrast series acquired at 45, 90,180, and 360 s) was performed on 29 patients with indeterminate lung nodules (14 benign, 15 malignant). A thoracic radiologist identified the boundary of each nodule using semi-automated contouring to form a 3D region-of-interest (ROI) on each image series. The post-contrast series having the maximum mean enhancement was then volumetrically registered to the baseline series. The two series were subtracted volumetrically and the subtracted voxels were quantized into seven color-coded bins, forming a contrast enhancement map (CEM). Conventional nodule densitometry was performed to obtain the maximum difference in mean enhancement values for each nodule from a circular ROI. Three thoracic radiologists performed visual semi-quantitative analysis of each nodule, scoring each map for: (a) magnitude and (b) heterogeneity of enhancement throughout the entire volume of the nodule on a five-point scale. Receiver operator characteristic (ROC) analysis was conducted on these features to evaluate their diagnostic efficacy. Finally, 14 quantitative texture features were calculated for each map. A statistical analysis was performed to combine the 14 texture features to a single factor. ROC analysis of the derived aggregate factor was done as an indicator of malignancy. All features were analyzed for differences between benign and malignant nodules. Results: Using 15 HU as a threshold, 93% (14/15) of malignant and 79% (11/14) of benign nodules demonstrated enhancement. The ROC curve when higher values of enhancement indicate malignancy was generated and area under the curve (AUC) was 0.76. The visually scored magnitude of enhancement was found to be

  9. Craniopharyngioma identification by CT and MR imaging at 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Hald, J.K. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States); Eldevik, O.P. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States); Skalpe, I.O. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States)

    1995-03-01

    To compare the detectability of craniopharyngiomas by CT and MR imaging, preoperative CT and MR studies obtained within 16 days of each other were evaluated retrospectively in 9 patients. MR imaging demonstrated cystic and solid tumor components in all 9 tumors, and enhancement in the 7 tumors that were studied after contrast medium injection. MR imaging demonstrated a signal void consistent with calcification in 4 patients. Combining unenhanced and contrast medium-enhanced studies, CT also identified all the tumors. CT demonstrated cysts in 7 lesions, calcification in 7 and enhancement in 6 of the 7 lesions that received i.v. contrast medium. Calcification was better seen by CT than MR imaging, while MR imaging identified cystic tumor components not seen on CT. The contrast medium enhancement pattern was the same with the 2 modalities. MR imaging of the sellar region, including at least one contrast medium-enhanced sequence, should be sufficient in most instances to establish a preoperative diagnosis of craniopharyngioma. (orig.).

  10. Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors.

    Science.gov (United States)

    Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun

    2017-04-05

    Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0.36 and -1.716 for liver, -0.153 and -1.546 for pancreas, and 2.427 and 0.866 for renal cortex, all P> 0.05). Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t = -8.11 for liver, -7.83 for pancreas, and -5.38 for renal cortex, all P 3, indicating clinically acceptable image quality. Single-phase, dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality.

  11. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Kim, Tae Kyoung; Khalili, Korosh [University of Toronto, Department of Medical Imaging, University Health Network, Toronto, ON (Canada); Bae, Mi Hyun; Lee, Joo Yeon [University of Ulsan College of Medicine, Seoul (Korea); Lee, Sung-Gyu [University of Ulsan College of Medicine, Asan Medical Center, Division of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, Seoul (Korea); Yu, Eun Sil [University of Ulsan College of Medicine, Asan Medical Center, Department of Diagnostic Pathology, Seoul (Korea)

    2010-02-15

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ({sub pre} L-S) and contrast-enhanced ({sub post} L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ({sub post} L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for{sub pre} L-S,{sub post} L-S and{sub post} L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of{sub pre} L-S and{sub post} L-S did not differ (P {>=} 0.054), despite a trend towards a lower accuracy with{sub post} L-S.{sub post} L-B yielded higher accuracy than{sub pre} L-S at threshold levels of 5% and 10% (P {<=} 0.002) and similar accuracy to{sub pre} L-S at the other threshold levels (P {>=} 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  12. Local recurrence of rectal cancer: MR imaging before and after oral superparamagnetic particles vs contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Blomqvist, L.; Ohlsen, H.; Holm, T.

    2000-01-01

    The aim of this study was to compare three imaging strategies for the diagnosis of local recurrence of rectal cancer: (a) MR imaging; (b) MR imaging after administration of enteral superparamagnetic particles (Ferristene); and (c) contrast-enhanced CT. Seventeen patients with previous surgery for rectal cancer were examined, 12 patients with local tumour recurrence in the pelvis and 5 patients with postoperative changes. Pelvic multi-coil MR imaging before and after oral administration of superparamagnetic contrast medium [Abdoscan (Ferristene USAN), Nycomed-Amersham, Lidingoe, Sweden] as well as abdominal and pelvic CT was performed in all patients. The examinations were independently evaluated by three different radiologists. The general effect of the oral MR contrast medium, the delineation of normal and pathological structures as well as confidence in the diagnosis were registered on a visual analog scale (VAS). The diagnosis according to MR before and after oral contrast medium, and CT, was compared, in 16 patients, with the final diagnosis which was verified by biopsy (n = 3), surgery (n = 6), clinical follow-up (n = 4) and by follow-up with MR or CT (n = 3). No significant improvement in MR image quality was found after enteral contrast medium. The post-contrast MR diagnosis was not changed in any of the patients. The diagnosis on MR correlated with the final diagnosis in 12 of 16 patients (sensitivity 91 %, accuracy 62 %) and the diagnosis on CT in 11 of 16 patients (sensitivity 82 %, accuracy 56 %). The radiologists' ''confidence'' in the diagnosis and the degree of accordance with the final diagnosis did not score higher on MR after than before oral contrast administration; however, the accordance with the final diagnosis scored better on MR than on CT. No advantages of orally administered superparamagnetic contrast medium were observed in the examined patient group. Magnetic resonance is preferable to CT in diagnosing local tumour recurrence. (orig.)

  13. Initial Experience of Using Dual-Energy CT with an Iodine Overlay Image for Hand Psoriatic Arthritis: Comparison Study with Contrast-enhanced MR Imaging.

    Science.gov (United States)

    Fukuda, Takeshi; Umezawa, Yoshinori; Tojo, Shinjiro; Yonenaga, Takenori; Asahina, Akihiko; Nakagawa, Hidemi; Fukuda, Kunihiko

    2017-07-01

    Purpose To determine the feasibility of dual-energy (DE) computed tomography (CT) with an iodine overlay image (IOI) for evaluation of psoriatic arthritis in the hand. Materials and Methods Approval from the institutional ethics committee and written informed consent from all patients were obtained. This prospective study included 16 patients who had psoriasis with finger joint symptoms from January 2015 to January 2016. Contrast material-enhanced (CE) DE CT and 1.5-T CE magnetic resonance (MR) imaging were performed within 1 month of each other. DE CT was performed with a tube voltage of 80 kV and 140 kV with use of a 0.4-mm tin filter. Images acquired with both modalities were evaluated by two radiologists independently by using a semiquantitative scoring system. Interreader agreement was calculated for each modality: Weighted κ values were calculated for synovitis, flexor tenosynovitis, and extensor peritendonitis, and κ values were calculated for periarticular inflammation. With consensus scores and CE MR images as the reference, the sensitivity and specificity of IOI DE CT for inflammatory lesions were calculated. Statistical analysis of discordant readings was performed by using the McNemar test. Results Interreader agreement for inflammatory lesions was excellent or good (weighted κ = 0.83 and κ = 0.75 in IOI DE CT; weighted κ = 0.81 and κ = 0.87 in CE MR imaging). The sensitivity and specificity of IOI DE CT were 0.78 and 0.87, respectively. Total agreement was 86.3%; however, there were significantly more lesions detected with IOI DE CT than with CE MR imaging alone (134 vs 20 lesions in 1120 evaluated items; P the abnormalities detected with IOI DE CT alone were located in distal interphalangeal joints. Conclusion IOI DE CT is a new imaging modality that may be useful for evaluating psoriatic arthritis in the hand, particularly in the detection of inflammatory lesions in small joints, and may be more useful than CE MR imaging, within the limitation

  14. Examination of hepatic dynamic CT images following infusion of high-concentration contrast media

    International Nuclear Information System (INIS)

    Takeyama, Nobuyuki; Hayashi, Takaki; Kinebuchi, Yuko; Kitahara, Tadashi; Ohbuchi, Masao; Shinjyo, Hidenori; Ohgiya, Yoshimitsu

    2008-01-01

    There are scarce examinations on the integrated effects of given iodine weight (mgI) and its rate (mgI/sec) on the quality and diagnostic accuracy in the hepatic contrast CT imaging while the former is known to affect the image of parenchyma and the latter, of arterial systems. The purpose of this study is to analyze and evaluate the effects qualitatively and quantitatively in hepatic dynamic CT images of patients with moderate body weight in whom different concentrations of I are given at the same flux rate and total weight. Patients having chronic hepatitis suspicious of carcinoma, or cirrhosis were 52-84 years old (M 50/F 55, b. wt. 50-65 kg) and were randomly divided in A and B group. A group received infusion of 25 sec in the right elbow vein of iopamidol, 300 mgI/100 mL, and B group, 370 mgI/80 mL: the I flux of ca. 1.2 gI/sec and total I of ca. 30 gI. Before and at 25 (early arterial phase), 40 (late art. phase), 70 (portal vein) and 180 (equilibrium) sec after infusion, CT images were obtained with the machine Light Speed select (GE Healthcare), Housfield Units before and after enhancing were used for quantitative evaluation, three experts qualitatively read images, and PACS system in Synapse 3.1.0 (Fuji Film Med.) was used for observation of tumor nodules if present. Neither qualitative nor quantitative differences were found in these CT images of the 4 phases and use of high-concentration contrast media was confirmed to be possible for lowered infusion rate. Authors also pointed out the importance of care for radiation exposure in this CT technique. (R.T.)

  15. Helical CT finding of carotid-cavernous fistula: a sign of early enhancing superior ophthalmic vein

    International Nuclear Information System (INIS)

    Kim, Jae Hyung; Na, Dong Gyu; Byun, Hong Sik; Ryoo, Jae Wook

    2000-01-01

    The purpose of this study was to determine the diagnostic value of a sign of early enhancing superior ophthalmic vein (SOV), as seen on helical CT images in patients with carotid-cavernous fistula (CCF). This study involved 16 patients with CCF and 28 control patients. Axial CT images with scanning delays of 30 seconds following bolus injection of contrast material (90 mL, 3 mL/sec) were obtained, and this procedure was followed by coronal CT imaging. To determine the presence or absence of early enhancement or, dilatation of the SOV, bulging of the cavernous sinus, and enlargement of extraocular muscle, CT images were analysed by three observers in a blinded, random manner. Early enhancement of SOV was determined to be present where enhancement of the SOV was similar to or stronger than that of the ipsilateral posterior cerebral artery. A sign of early enhancing SOV was seen in 14 of the 16 patients with CCF but in no control patients (88% sensitivity and 100% specificity). The respective sensitivity and specificity of other CT features were 71% and 100% (dilatation of the SOV, as seen on axial images), 60% and 83% (dilatation of the SOV, as seen on coronal images), 71% and 89% (dilatation of the cavernous sinus), and 65% and 98% (enlargement of extraocular muscle). A sign of early enhancing SOV is a characteristic and specific CT finding of CCF, and is useful for the diagnosis of CCF. (author)

  16. CT Image Contrast of High-Z Elements: Phantom Imaging Studies and Clinical Implications.

    Science.gov (United States)

    FitzGerald, Paul F; Colborn, Robert E; Edic, Peter M; Lambert, Jack W; Torres, Andrew S; Bonitatibus, Peter J; Yeh, Benjamin M

    2016-03-01

    To quantify the computed tomographic (CT) image contrast produced by potentially useful contrast material elements in clinically relevant imaging conditions. Equal mass concentrations (grams of active element per milliliter of solution) of seven radiodense elements, including iodine, barium, gadolinium, tantalum, ytterbium, gold, and bismuth, were formulated as compounds in aqueous solutions. The compounds were chosen such that the active element dominated the x-ray attenuation of the solution. The solutions were imaged within a modified 32-cm CT dose index phantom at 80, 100, 120, and 140 kVp at CT. To simulate larger body sizes, 0.2-, 0.5-, and 1.0-mm-thick copper filters were applied. CT image contrast was measured and corrected for measured concentrations and presence of chlorine in some compounds. Each element tested provided higher image contrast than iodine at some tube potential levels. Over the range of tube potentials that are clinically practical for average-sized and larger adults-that is, 100 kVp and higher-barium, gadolinium, ytterbium, and tantalum provided consistently increased image contrast compared with iodine, respectively demonstrating 39%, 56%, 34%, and 24% increases at 100 kVp; 39%, 66%, 53%, and 46% increases at 120 kVp; and 40%, 72%, 65%, and 60% increases at 140 kVp, with no added x-ray filter. The consistently high image contrast produced with 100-140 kVp by tantalum compared with bismuth and iodine at equal mass concentration suggests that tantalum could potentially be favorable for use as a clinical CT contrast agent.

  17. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, N.G. [University of Otago, Department of Radiology, Christchurch (New Zealand); Butler, A.P. [University of Otago, Department of Radiology, Christchurch (New Zealand); University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Scott, N.J.A. [University of Otago, Department of Medicine, Christchurch (New Zealand); Cook, N.J. [Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Butzer, J.S. [Karlsruhe Institute of Technology, Physics Department, Karlsruhe (Germany); Schleich, N. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Firsching, M. [Friedrich Alexander University, Physics Department, Erlangen (Germany); Grasset, R.; Ruiter, N. de [University of Canterbury, Hitlab NZ, Christchurch (New Zealand); Campbell, M. [European Organisation for Nuclear Research, Physics Section, Geneva (Switzerland); Butler, P.H. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand)

    2010-09-15

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 {mu}A). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at <55 {mu}m isotropic voxels. Spectral CT distinguishes contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications. (orig.)

  18. High contrast enhancement aspect of dynamic computed tomography with arterial infusion - DCT-AI

    International Nuclear Information System (INIS)

    Kato, Seishi; Iwasaki, Naoya; Matsumura, Yoshimitsu; Kuramae, Shigeru; Mishiro, Tadashi

    1983-01-01

    Dynamic computed tomography was performed on 112 cases possibly having hepatic tumors with intraarterial infusion of undiluted contrast into a selectively placed catheter following angiographies. Our dynamic program could evaluate not only early phase of enhancement but also late phase up to 120 sec. Reconstructed views from early scans and magnified views were very useful to evaluate minute sequential changes. Hepatic masses less than 5 cm in size were found in thirty-one cases. Patterns of tumor enhancement and time-density curves have been analysed to correlate them with histology. Four types of tumor enhancement were noted: (1) homogeneous (2) patchy (3) mottled (4) ringed. Characteristic changes were observed in hepatocellular carcinoma - HCC - (mostly mottled) and haemangioma (mostly patchy). The former was divided in two groups reflecting the cellular maturity. The metastatic tumor could be enhanced in a ringed form with dendritic pattern of supplying vascularities in some cases. To support the use of undiluted contrast and to investigate the diagnostic efficacy of high contrast enhancement, experiments were performed by taking transaxial views of an acrylic phantom immersed in different concentrations of contrast. Analysis of CT images taken at different HU values ranging from 0 to 450 demonstrated that the higher the concentration of contrast, the better the spatial resolution was. Also larger magnification could be expected by using higher concentration of contrast. Although our Dynamic Computed Tomography with Arterial Infusion of Contrast still has drawbacks and limited indications, we advocate it as a better way of enhancement to detect and evaluate the hepatic masses, which sometimes elude the examiner's grasp with conventional way of enhancement. (author)

  19. Diagnostic value of contrast-enhanced ultrasonography in the characterization of ovarian tumors().

    Science.gov (United States)

    Sconfienza, L M; Perrone, N; Delnevo, A; Lacelli, F; Murolo, C; Gandolfo, N; Serafini, G

    2010-03-01

    Vascularity influences the characteristics of gynecologic tumors observed with direct imaging techniques that reveal the macrovascular component of these lesions (color and power Doppler) and with indirect imaging involving the administration of contrast agents to examine the microcirculation and interstitial perfusion (contrast-enhanced computed tomography [CT] and magnetic resonance [MR] imaging). The purpose of this study was to determine whether contrast-enhanced ultrasonography (CEUS) of ovarian lesions provides useful information that cannot be obtained with conventional US. We used CEUS to assess 72 nonspecific adnexal lesions in 61 patients. CEUS was performed with a 4.8-ml bolus of a second-generation ultrasonographic contrast agent and dedicated imaging algorithms. For each lesion, B-mode morphology, CEUS morphology, and time/intensity curves were evaluated. In 8/61 cases (13.1%) CEUS offered no additional morphovascular information. In 38/61 cases (62.3%), it provided additional information that did not modify the management of the lesion, and in 15/61 cases (24.6%) it gave additional information that modified the management of the lesion. Malignant lesions were characterized by significantly shorter times to peak enhancement (11.9 ± 3.1 s vs 19.8 ± 4.0 s p < 0.01) and significantly higher peak intensity (24.7 ± 4.2 dB vs 17.8 ± 3.3 dB p < 0.01) compared with benign lesions. CEUS improves diagnostic confidence in the characterization of liquid-corpuscular lesions where conventional US is inconclusive. CEUS can be proposed as a valid alternative to CT and MR. However, information obtained by CEUS influences the therapy in a limited percentage of cases (24.6%).

  20. Wedge-shaped parenchymal enhancement peripheral to the hepatic hemangioma : two-phase spiral CT findings

    International Nuclear Information System (INIS)

    Kim, Kyoung Won; Kim, Tae Kyoung; Han, Joon Koo; Kim, Ah Young; Lee, Hyun Ju; Song, Chi Sung; Choi, Byung Ihn

    2000-01-01

    To determine the incidence of hepatic hemangiomas associated with wedge-shaped parenchymal enhancements adjacent to the tumors as seen on two-phase spiral CT images obtained during the hepatic arterial phase and to characterize the two-phase spiral CT findings of those hemangiomas. One hundred and eight consecutive hepatic hemangiomas in 63 patients who underwent two-phase spiral CT scanning during an 11-month period were included in this study. Two-phase spiral CT scans were obtained during the hepatic arterial phase (30-second delay) and portal venous phase (65-second delay) after injection of 120 mL of contrast material at a rate of 3 mL/sec. We evaluated the frequency with which wedge-shaped parenchymal enhancement was adjacent to the hemangiomas during the hepatic arterial phase and divided hemangiomas into two groups according to whether or not wedge-shaped parenchymal enhancement was noted (Group A and Group B). The presence of such enhancement in hemangiomas was correlated with tumor size and the grade of intratumoral enhancement. In 24 of 108 hemangiomas, wedge-shaped parenchymal enhancement adjacent to hepatic tumors was seen on two-phase CT images obtained during the hepatic arterial phase. Mean hemangioma size was 22mm in group A and 24mm in group B. There was no statistically significant relationship between lesion size and the presence of wedge-shaped parenchymal enhancement adjacent to a hemangioma. In 91.7% and 100% of tumors in Group A, and in 9.6% and 17.8% in Group B, hemangiomas showed more than 50% intratumoral enhancement during the arterial and portal venous phase, respectively. Wedge-shaped parenchymal enhancements peripheral to hepatic hemangiomas was more frequently found in tumors showing more than 50% intratumoral enhancement during these two phases (p less than 0.01). Wedge-shaped parenchymal enhancements is not uncommonly seen adjacent to hepatic hemangiomas on two-phase spiral CT images obtained during the hepatic arterial phase. A

  1. Extravasation of contrast medium during CT examination: An ...

    African Journals Online (AJOL)

    2013-03-31

    Extravasation of contrast medium during CT examination: An observational casecontrol study. ... Methods: every incident of extravasation which occurred between March 2012 and March 31, 2013 was recorded in an extravasation form. Ethics Committee approval was obtained and the patients gave their consent to ...

  2. CT contrasting theory. Effects of the concentration, volume and infusion rate of iodine contrast medium on TDC

    International Nuclear Information System (INIS)

    Yamachi, Jun

    2007-01-01

    This study was performed to evaluate the effects in the title on TDC (time-density curve) using a phantom. CT machine used was Toshiba Aquilion Multi 64, TDC phantom was the product of Nemoto-Kyorindo Co., and the contrast medium was Eisai iomeprol, in syringe-sealed formulations of 300 and 350 mg I/mL. The medium was infused at 1-5 mL/sec in the phantom equivalent to body weight of 78 kg (total water volume=1 min circulation=6,000 mL, 800 mL/heart) to obtain 30 TDCs. Evaluated were the relationships of the infusion rate (mL/sec), volume (mL) or time (sec) with TDC parameters of the detection time of the medium, slope, time to reach the maximum CT value, the maximum CT value, time to keep the CT concentration and its actual concentration. Results revealed that, regardless to the difference of formulations of the contrast medium, TDC with high reproducibility can be obtainable by making the infusion rate of I per unit time and body weight (mgI/sec/kg) constant when the infusion time is made identical for CT of the same diagnostic purpose. (R.T.)

  3. Non-contrast thin-section helical CT of urinary tract calculi in children

    International Nuclear Information System (INIS)

    Strouse, Peter J.; Bates, Gregory D.; Bloom, David A.; Goodsitt, Mitchell M.

    2002-01-01

    Background: Non-contrast thin-section helical CT has gained acceptance for the diagnosis of urinary tract calculi in adults, but experience with the technique in children is limited. Purpose: To evaluate the utility of non-contrast thin section helical CT for the diagnosis of urinary tract calculi in children. Materials and methods: Radiology databases at three pediatric institutions were searched to identify all pediatric patients evaluated by ''renal stone'' protocol CT scans (no oral or intravenous contrast, scans covering the entire urinary tract obtained in helical mode with narrow collimation (< 5 mm)). CT scans were reviewed for the primary finding of urinary tract calculi, for secondary signs of acute urinary tract obstruction and for evidence of alternative diagnoses. Medical records were reviewed to determine clinical presentation and to confirm the eventual diagnosis. Results: One hundred thirty-seven scans of 113 children (mean age: 11.2 years) were studied. Thirty-eight of 94 examinations (40%) performed on 82 children for acute pain and/or hematuria showed ureteral calculi. Alternative diagnoses were suggested by CT on 16 scans (17%). Twenty-eight scans were performed on 10 asymptomatic children with known calculus disease confirming renal stone burden on 21 scans (75%) and persistent ureteral calculi on 6 scans (21%). Upper tract calculi were demonstrated on 10 of 15 scans (67%) performed to evaluate for calculi in patients with known non-calculus genitourinary tract abnormalities. Conclusions: Non-contrast thin section helical CT is a useful method to diagnose urinary tract calculi in children. Radiation dose in this retrospective study may exceed the lowest possible radiation dose for diagnostic accuracy. Further research is needed to optimize CT imaging parameters, while maintaining diagnostic accuracy and minimizing radiation dose. (orig.)

  4. Comparison of renal toxicity after injection of CT contrast medium and MR contrast medium: change of renal function in acute renal failure rat models

    International Nuclear Information System (INIS)

    Han, Young min; Lee, Young Hwan; Kim, Sang Won; Jin, Kong Young; Kim, Won; Chung, Gyung Ho

    2002-01-01

    To determine renal toxicity through changes in renal function after the injection of CT and MRI contrast media into rats in which acute renal failure (ARF) was induced. To cause acute renal failure, the abdominal cavity of 110 male rats each weighing 250-300 gm was opened via a midline incision under anesthesia. Microvascular clamps were placed on both renal arteries and veins to completely block renal blood flow for 45 minutes, and were then removed, allowing blood flow to return to the kidneys. ARF, defined as a two-fold difference in the creatinine level before ARF and 48 hours after, was successfully induced in 60 of the rats. These were divided into two groups: one was injected with CT contrast medium and the other with MRI contrast medium. Each CT and MRI group was divided into a low dose (0.5 cc/kg, 0.2 ml/kg), standard dose (2 cc/kg, 0.8 ml/kg), and high dose (8 cc/kg, 3.2 ml/kg) sub-group; thus, there was a total of six groups with ten rats in each. Blood samples were obtained before ARF, 48 hours after, and 48 hours after contrast injection, and CT scanning and MRI were performed after blood sampling at 48 hours. In each group, creatinine levels 48 hours after contrast injection were compared by means of the ANOVA test. There were no significant differences in creatinine levels between the CT and MRI contrast medium groups (p=0.116), nor between the animals to which different doses of CT and MRI contrast medium, were administered. After both standard and high doses, CT and MRI provided good images. In rats in which acute renal failure was induced, renal function did not change according to whether CT or MRI contrast medium was injected. Thus, the two media induce similar levels of toxicity

  5. Regions of low density in the contrast-enhanced pituitary gland: normal and pathologic processes

    International Nuclear Information System (INIS)

    Chambers, E.F.; Turski, P.A.; LaMasters, D.; Newton, T.H.

    1982-01-01

    The incidence of low-density regions in the contrast-enhanced pituitary gland and the possible causes of these regions were investigated by a retrospective review of computed tomographic (CT) scans of the head in 50 patients and autopsy specimens of the pituitary in 100 other patients. It was found that focal areas of low density within the contrast enhanced pituitary gland can be caused by various normal and pathologic conditions such as pituitary microadenomas, pars intermedia cysts, foci of metastasis, infarcts, epidermoid cysts, and abscesses. Although most focal low-density regions probably represent pituitary microadenomas, careful clinical correlation is needed to establish a diagnosis

  6. Pancreatic neuroendocrine tumors containing areas of iso- or hypoattenuation in dynamic contrast-enhanced computed tomography: Spectrum of imaging findings and pathological grading.

    Science.gov (United States)

    Hyodo, Ryota; Suzuki, Kojiro; Ogawa, Hiroshi; Komada, Tomohiro; Naganawa, Shinji

    2015-11-01

    To evaluate dynamic contrast-enhanced computed tomography (CT) features of pancreatic neuroendocrine tumors (PNETs) containing areas of iso- or hypoattenuation and the relationship with pathological grading. Between June 2006 and March 2014, 61 PNETs in 58 consecutive patients (29 male, 29 female; median-age 55 years), which were surgically diagnosed, underwent preoperative dynamic contrast-enhanced CT. PNETs were classified based on contrast enhancement patterns in the pancreatic phase: iso/hypo-PNETs were defined as tumors containing areas of iso- or hypoattenuation except for cystic components, and hyper-PNETs were tumors showing hyperattenuation over the whole area. CT findings and contrast-enhancement patterns of the tumors were evaluated retrospectively by two radiologists and compared with the pathological grading. Iso/hypo-PNETs comprised 26 tumors, and hyper-PNETs comprised 35 tumors. Not only hyper-PNETs but also most iso/hypo-PNETs showed peak enhancement in the pancreatic phase and a washout from the portal venous phase to the delayed phase. Iso/hypo-PNETs showed larger tumor size than the hyper-PNETs (mean, 3.7 cm vs. 1.6 cm; PIso/hypo-PNETs also showed significantly higher pathological grading (WHO 2010 classification; iso/hypo, G1=14, G2=11, G3=1; hyper, G1=34, G2=1; Piso/hypo-areas showed a rapid enhancement pattern as well as hyper-PNETs, various radiological features and higher malignant potential. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Chondroitin sulfate iron colloid-enhanced MR imaging in patients with hepatocellular carcinoma. Comparison with CT during arterial portography

    Energy Technology Data Exchange (ETDEWEB)

    Kamba, Masayuki [Dept. of Radiology, Tottori Univ., Yonago (Japan); Suto, Y. [Dept. of Radiology, Tottori Univ., Yonago (Japan); Kato, T. [Dept. of Radiology, Tottori Univ., Yonago (Japan)

    1994-11-01

    Chondroitin sulfate iron colloid (CSIC) was used as an MR contrast agent for the detection of hepatocellular carcinoma (HCC). The findings of 25 surgically confirmed HCCs in 19 patients were retrospectively analyzed. T1-, T2- and proton density-weighted spin echo MR images were obtained before and after i.v. injection of 23.6 {mu}M Fe/kg of CSIC. Unenhanced and CSIC-enhanced MR images and images obtained by CT during arterial protography (CT-AP) were correlated with surgical pathology findings. The sensitivities of CSIC-enhanced and unenhanced MR imaging, and CT-AP were 92%, 80%, and 88%, respectively. No significant differences were noted. Portal flow abnormalities demonstrated by CT-AP did not affect the detection of HCC by CSIC-enhanced MR imaging. CSIC-enhancement at MR imaging was a disadvantage in the detection of lesions less than 1 cm in diameter. CSIC-enhanced MR imaging is a supplemental method for the detection of HCC. (orig.).

  8. Castleman disease of the neck: CT and MR imaging findings

    International Nuclear Information System (INIS)

    Jiang, Xin-hua; Song, Hao-ming; Liu, Qing-yu; Cao, Yun; Li, Guo-hong; Zhang, Wei-dong

    2014-01-01

    Objective: To characterize the computed tomography (CT) and magnetic resonance imaging (MRI) findings of Castleman disease of the neck. Methods: The imaging findings of 21 patients with Castleman disease of the neck were reviewed retrospectively. Of the 21 patients, 16 underwent unenhanced and contrast-enhanced CT scans; 5 underwent unenhanced and contrast-enhanced MRI scans. Results: The unenhanced CT images showed isolated or multiple well-defined homogenous mild hypodensity lesions in fifteen cases, and a heterogeneous nodule with central areas of mild hypodensity in one case. Calcification was not observed in any of the patients. In five patients, MR T1-weighted images revealed well-defined, homogeneous isointense or mild hyperintense lesions to the muscle; T2-weighted images showed these as intermediate hyperintense. Sixteen cases showed intermediate to marked homogeneous enhancement on contrast-enhanced CT or MR T1-weighted images. Of the other five cases that underwent double-phase CT scans, four showed mild or intermediate heterogeneous enhancement at the arterial phase, and homogeneous intermediate or marked enhancement at the venous phase; the remaining case showed mild and intermediate ring-enhancement with a central non-enhanced area at the arterial and venous phases, respectively. Conclusion: Castleman disease of the neck can be characterized as solitary or multiple well-defined, mild hypodensity or homogeneous intense lesions on plain CT/MR scans, and demonstrates intermediate and marked enhancement on contrast-enhanced CT/MR scans. On double-phase CT scans, Castleman disease often demonstrates mild enhancement at the arterial phase, and gradually uniform enhancement at venous phase. Double-phase enhanced CT or MRI may help to differentiate Castleman disease from other diseases

  9. Castleman disease of the neck: CT and MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xin-hua [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Song, Hao-ming [Department of Cardiology, Shanghai Tongji Hospital, Shanghai 200065 (China); Liu, Qing-yu [Department of Radiology, The Second Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510120 (China); Cao, Yun [Department of Pathology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Li, Guo-hong [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Zhang, Wei-dong, E-mail: dongw.z@163.com [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China)

    2014-11-15

    Objective: To characterize the computed tomography (CT) and magnetic resonance imaging (MRI) findings of Castleman disease of the neck. Methods: The imaging findings of 21 patients with Castleman disease of the neck were reviewed retrospectively. Of the 21 patients, 16 underwent unenhanced and contrast-enhanced CT scans; 5 underwent unenhanced and contrast-enhanced MRI scans. Results: The unenhanced CT images showed isolated or multiple well-defined homogenous mild hypodensity lesions in fifteen cases, and a heterogeneous nodule with central areas of mild hypodensity in one case. Calcification was not observed in any of the patients. In five patients, MR T1-weighted images revealed well-defined, homogeneous isointense or mild hyperintense lesions to the muscle; T2-weighted images showed these as intermediate hyperintense. Sixteen cases showed intermediate to marked homogeneous enhancement on contrast-enhanced CT or MR T1-weighted images. Of the other five cases that underwent double-phase CT scans, four showed mild or intermediate heterogeneous enhancement at the arterial phase, and homogeneous intermediate or marked enhancement at the venous phase; the remaining case showed mild and intermediate ring-enhancement with a central non-enhanced area at the arterial and venous phases, respectively. Conclusion: Castleman disease of the neck can be characterized as solitary or multiple well-defined, mild hypodensity or homogeneous intense lesions on plain CT/MR scans, and demonstrates intermediate and marked enhancement on contrast-enhanced CT/MR scans. On double-phase CT scans, Castleman disease often demonstrates mild enhancement at the arterial phase, and gradually uniform enhancement at venous phase. Double-phase enhanced CT or MRI may help to differentiate Castleman disease from other diseases.

  10. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... initially used as Doppler signal enhancers, second-generation microbubble contrast agents are now used with specific contrast harmonic imaging techniques, which benefit from the highly nonlinear behavior of the microbubbles. Contrast-specific modes based on multi-pulse technology are used to perform...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  11. Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jia; Qu, Mingliang; Duan, Xinhui; Takahashi, Naoki; Kawashima, Akira; Leng, Shuai; McCollough, Cynthia H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2012-12-15

    To develop a dual-energy CT (DECT) method for differentiating uric acid (UA) from non-UA stones in the presence of iodinated contrast medium. Thirty UA and 45 non-UA stones were selected after infra-red spectroscopic analysis and independently placed in a 1.5-ml vial, which was filled first with saline and then with increasing concentrations of iodine. For each condition, tubes were put in a 35-cm water phantom and examined using a dual-source CT system at 100 and 140 kV. Virtual unenhanced images created from CT data sets of the stones in iodine-containing solutions provided position and volume information. This map was used to calculate a CT number ratio to differentiate stone type. A region-growing method was developed to improve the ability to differentiate between UA and non-UA stones with iodinated contrast medium. The sensitivity for detecting UA stones was 100 % for unenhanced images but fell to 18 % with 20 mgI/ml iodine solution and 0 % for higher concentrations. With region growing, the sensitivity for detecting UA stones was increased to 100 %, 82 %, 57 %, 50 % and 21 % for iodine solutions of 20, 40, 60, 80 and 100 mgI/ml. The region-growing method improves differentiation of UA from non-UA stones on contrast-enhanced DECT urograms. (orig.)

  12. Contrast Enhanced US in the Abdomen

    International Nuclear Information System (INIS)

    Chung, Yong Eun; Kim, Ki Whang

    2012-01-01

    Contrast enhanced ultrasound, which was introduced in 1996, has been widely used in Europe and Eastern Asia. Ultrasound contrast agent can be classified as first generation and second generation, depending on the gas within the microbubble. With the first generation contrast agent, the high MI technique was used, and only intermittent scanning was possible due to destruction of the microbubble during scanning. Use of the second generation contrast agent with the low MI technique makes continuous scanning possible. Contrast enhanced US can be used in detection and differentiation of focal liver lesions. It is also helpful for monitoring of radiofrequency ablation and for targeting of US guided biopsy. Currently, because morphologic criteria alone may not reflect the response of the tumor to treatment, new criteria are needed for treatment evaluation after administration of anti-angiogenic agents. Contrast enhanced US could provide quantitative markers for evaluation of the response to treatment via use of dynamic contrast enhanced US. Due to cost-effectiveness, contrast enhanced US is not yet widely used in Korea; however, considering recent issues regarding contrast agent related adverse reaction, such as contrast induced nephropathy and nephrogenic systemic fibrosis, and radiation exposure, contrast enhanced US might be more widely used in Korea, as an alternative imaging modality in the future.

  13. Contrast enhancement by arterial perfusion during computed tomography (computed tomographic arteriography) of the pancreatic disease

    International Nuclear Information System (INIS)

    Takaki, Yukiari

    1983-01-01

    Computed tomographic arteriography (CTA) was performed on 52 cases of pancreatic disease in which was suspected clinically, and in which other method failed to yield a definitive diagnosis. For CTA, 65% meglumine diatrizoate 20 ml, diluted 1:3, was injected via a catherter inserted in an artery connected with the pancreas and the change with time of the pacreas CT number was studied. The normal pancreas stains deeply and the best contrast enhancement was obtained between 17 to 21 seconds after instillation of contrast medium. In the CTA findings in pancreatic cancer, low density areas with irregular internal structures are characteristic, and these characteristics were seen even in minute pancreatic cancers which could not be recognized by CT or the intravenous bolus injection method. On the other hand, in chronic pancreatitis, even when differentiation from pancreatic cancer is difficult with arterial and venous encasement in angiography, as long as the chronic pancreatitis is not very advanced ischemic changes are not seen, and this permits differentiation form normal pancreas. This also facilitates differentiation between pancreatitis and pancreatic cancer. In the intravenous bolus injection method, the chronological change of contrast enhancement in the pancreas was studied and the best contrast enhancement was obtained after 60 to 120 seconds. This method revealed no findings peculiar to pancreatic cancer. Based on the above, CTA was found to be useful for making in contributing to establishing a definitive diagnosis, detecting minute pancreatic cancer and to differentiate pancreatic cancer from chronic pancreatitis. (author)

  14. Gynecological applications of helical CT using SmartPrep

    Energy Technology Data Exchange (ETDEWEB)

    Sakurada, Akira; Kakizaki, Dai; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1999-11-01

    SmartPrep is software program for scanning a given region of interest (ROI) at optimal contrast density. An operator can arbitrarily define ROI and preset the CT value at which scanning should be started. After the injection of a contrast medium, system conducts continuous monitoring of the ROI and the operator starts helical scanning of the planned region when the present CT value has been reached. In comparison with conventional helical CT that requires a period of time from the beginning of contrast medium injection to the beginning of scanning, SmartPrep minimizes personal error and better depicts the artery-predominant phase under optimal conditions. In this study we examine the usefulness of contrast-enhanced helical CT using SmartPrep in the evaluation of gynecological disease. When the contrast medium was injected into the dorsal vein of the hand at a rate of 3 ml/sec, strong staining of pelvic arteries was observed in the CT images started at 17 to 23 sec after injection. The early-phase helical CT obtained under these conditions provided good depiction of lesions in cases of placenta accreta and invasive mole, as well as clear demonstration of tumor angiogenesis and evaluation of laterality in cases of cervical cancer. Comparison of the early and delayed phase also facilitated easier evaluation of lymph nodes than conventional comparison of simple and contrast-enhanced CT. The results thus suggest the usefulness of contrast-enhanced helical CT using SmartPrep in gynecology. (author)

  15. Diagnostic accuracy of {sup 18}F-FDG PET/CT compared with that of contrast-enhanced MRI of the breast at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Magometschnigg, Heinrich F.; Baltzer, Pascal A.; Fueger, Barbara; Helbich, Thomas H.; Weber, Michael [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Vienna (Austria); Karanikas, Georgios [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Vienna (Austria); Dubsky, Peter [Medical University of Vienna, Department of Surgery, Vienna (Austria); Rudas, Margaretha [Medical University of Vienna, Department of Pathology, Vienna (Austria); Pinker, Katja [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Vienna (Austria); Molecular Imaging and Therapy Service, Memorial Sloan Kettering Cancer Center, New York (United States)

    2015-10-15

    To compare the diagnostic accuracy of prone {sup 18}F-FDG PET/CT with that of contrast-enhanced MRI (CE-MRI) at 3 T in suspicious breast lesions. To evaluate the influence of tumour size on diagnostic accuracy and the use of maximum standardized uptake value (SUV{sub MAX}) thresholds to differentiate malignant from benign breast lesions. A total of 172 consecutive patients with an imaging abnormality were included in this IRB-approved prospective study. All patients underwent {sup 18}F-FDG PET/CT and CE-MRI of the breast at 3 T in the prone position. Two reader teams independently evaluated the likelihood of malignancy as determined by {sup 18}F-FDG PET/CT and CE-MRI independently. {sup 18}F-FDG PET/CT data were qualitatively evaluated by visual interpretation. Quantitative assessment was performed by calculation of SUV{sub MAX}. Sensitivity, specificity, diagnostic accuracy, area under the curve and interreader agreement were calculated for all lesions and for lesions <10 mm. Histopathology was used as the standard of reference. There were 132 malignant and 40 benign lesions; 23 lesions (13.4 %) were <10 mm. Both {sup 18}F-FDG PET/CT and CE-MRI achieved an overall diagnostic accuracy of 93 %. There were no significant differences in sensitivity (p = 0.125), specificity (p = 0.344) or diagnostic accuracy (p = 1). For lesions <10 mm, diagnostic accuracy deteriorated to 91 % with both {sup 18}F-FDG PET/CT and CE-MRI. Although no significant difference was found for lesions <10 mm, CE-MRI at 3 T seemed to be more sensitive but less specific than {sup 18}F-FDG PET/CT. Interreader agreement was excellent (κ = 0.85 and κ = 0.92). SUV{sub MAX} threshold was not helpful in differentiating benign from malignant lesions. {sup 18}F-FDG PET/CT and CE-MRI at 3 T showed equal diagnostic accuracies in breast cancer diagnosis. For lesions <10 mm, diagnostic accuracy deteriorated, but was equal for {sup 18}F-FDG PET/CT and CE-MRI at 3 T. For lesions <10 mm, CE-MRI at 3 T seemed

  16. Topical contrast agents to improve soft-tissue contrast in the upper airway using cone beam CT: a pilot study.

    Science.gov (United States)

    Alsufyani, N A; Noga, M L; Finlay, W H; Major, P W

    2013-01-01

    The purpose of this study is to explore the topical use of radiographic contrast agents to enhance soft-tissue contrast on cone beam CT (CBCT) images. Different barium sulphate concentrations were first tested using an airway phantom. Different methods of barium sulphate application (nasal drops, syringe, spray and sinus wash) were then tested on four volunteers, and nebulized iodine was tested in one volunteer. CBCT images were performed and then assessed subjectively by two examiners for contrast agent uniformity and lack of streak artefact. 25.0% barium sulphate presented adequate viscosity and radiodensity. Barium sulphate administered via nasal drops and sprays showed non-uniform collection at the nostrils, along the inferior and/or middle nasal meatuses and posterior nasal choana. The syringe and sinus wash showed similar results with larger volumes collecting in the naso-oropharynx. Nebulized iodine failed to distribute into the nasal cavity and scarcely collected at the nostrils. All methods of nasal application failed to adequately reach or uniformly coat the nasal cavity beyond the inferior nasal meatuses. The key factors to consider for optimum topical radiographic contrast in the nasal airway are particle size, flow velocity and radio-opacity.

  17. Dynamic Contrast-Enhanced Magnetic Resonance Enterography and Dynamic Contrast-Enhanced Ultrasonography in Crohn's Disease

    DEFF Research Database (Denmark)

    Wilkens, Rune; Peters, David A; Nielsen, Agnete Hedemann

    2017-01-01

    Purpose e Cross-sectional imaging methods are important for objective evaluationof small intestinal inflammationinCrohn'sdisease(CD).The primary aim was to compare relative parameters of intestinal perfusion between contrast-enhanced ultrasonography (CEUS) and dynamic contrast-enhanced magnetic...

  18. Optimization of the Contrast Mixture Ratio for Simultaneous Direct MR and CT Arthrography: an in Vitro Study

    International Nuclear Information System (INIS)

    Choi, Ja Young; Hong, Sung Hwan; Kim, Na Ra; Jun, Woo Sun; Moon, Sung Gyu; Kang, Heung Sik; Lee, Joon Woo; Choi, Jung Ah

    2008-01-01

    This study was designed to determine the optimal mixture ratio of gadolinium and iodinated contrast agent for simultaneous direct MR arthrography and CT arthrography. An in vitro study was performed utilizing mixtures of gadolinium at six different concentrations (0.625, 1.25, 2.5, 5.0, 10 and 20 mmol/L) and iodinated contrast agent at seven different concentrations (0, 12.5, 25, 37.5, 50, 75 and 92-99.9%). These mixtures were placed in tissue culture plates, and were then imaged with CT and MR (with T1-weighted sequences, proton-density sequences and T2-weighted sequences). CT numbers and signal intensities were measured. Pearson's correlation coefficients were used to assess the correlations between the gadolinium/iodinated contrast agent mixtures and the CT numbers/MR signal intensities. Scatter diagrams were plotted for all gadolinium/iodinated contrast agent combinations and two radiologists in consensus identified the mixtures that yielded the optimal CT numbers and MR signal intensities. The CT numbers showed significant correlation with iodinated contrast concentrations (r = 0.976, p < 0.001), whereas the signal intensities as measured on MR images showed a significant correlation with both gadolinium and iodinated contrast agent concentrations (r = -484 to -0.719, p < 0.001). A review of the CT and MR images, graphs, and scatter diagram of 42 combinations of the contrast agent showed that a concentration of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was the best combination for simultaneous CT and MR imaging. A mixture of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was found to be optimal for simultaneous direct MR arthrography and CT arthrography

  19. A prospective evaluation of the contrast, radiation dose and image quality of contrast-enhanced CT scans of paediatric abdomens using a low-concentration iodinated contrast agent and low tube voltage combined with 70% ASIR algorithm.

    Science.gov (United States)

    Wang, Xiaoxia; Zhong, Yumin; Hu, Liwei; Xue, Lianyan; Shi, Meihua; Qiu, Haisheng; Li, Jianying

    2016-09-01

    To quantitatively and subjectively assess the image quality of and radiation dose for an abdominal enhanced computed tomography (CT) scan with a low tube voltage and a low concentration of iodinated contrast agent in children. Forty-eight patients were randomised to one of the two following protocols: Group A (n=24, mean age 46.96±44.65 months, mean weight 15.71±9.11 kg, BMI 16.48±2.40 kg/m(2) ) and Group B (n=24, mean age 41.33±44.59 months, mean weight 18.15±17.67 kg, BMI 17.50±3.73 kg/m(2) ). Group A: 80 kVp tube voltage, 270 mg iodine (I)/mL contrast agent (Visipaque, GE Healthcare) and images were reconstructed using 70% adaptive statistical iterative reconstruction (ASIR). Group B: 100 kVp tube voltage, 370 mg I/mL contrast agent (Iopamiro, Bracco) and images were reconstructed using 50% ASIR. The volume of the contrast agent was 1.30 mL/kg in both Groups A and B. The degree of enhancement and noise in the abdominal aorta (AO) in the arterial phase (AP) and the portal vein (PV) in the portal venous phase (PVP) was measured; while the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the AO and PV were calculated. A 5-point scale was used to subjectively evaluate the image quality and image noise by two radiologists with more than 10 years of experience. Dose-length product (DLP) (mGy-cm) and CTDIvol (mGy) were calculated. Objective measurements and subjective quality scores for the two groups were compared using paired t-tests and Mann-Whitney U tests, respectively. There was no significant difference in age, weight or body mass index (BMI) between the two groups (all P>.5). The iodine load in Group A (5517.3±3197.2 mg I) was 37% lower than that in Group B (8772.1±8474.6 mg I), although there was no significant difference between them (P=.111). The DLP and the CT dose index (CTDIvol ) for Group A were also lower than for Group B, but were not statistically significantly different (DLP, 104 mGy-cm±45.81 vs 224.5

  20. Evaluation of the diagnosis on staging of the bladder cancers by contrast-enhanced ultrasound

    International Nuclear Information System (INIS)

    Gao Yong; Xu Haiyan; Huan Haiming; Chen Yane

    2010-01-01

    Objective: To study the value of the staging of the bladder cancers with the contrast-enhanced ultrasound. Methods: After rapid injection of the contrast agent SonoVue through the elbow vein, the staging of images was completed in 18 cases of bladder cancer. Results: The results of contrast-enhanced ultrasound were compared with post-operative pathological analysis, the rate of accuracy of diagnosis on T1, T2, T3 and T4 stage was 100%, 80%, 83% and 100% respectively. The accuracy made by new methods higher than those of other imaging examinations in T1 stage; the other stages were similar to those of other imaging examinations. Conclusion: The evaluation of Contrast-enhanced ultrasound on the staging of the bladder cancer is higher than that of the conventional ultrasound examination, while the observation of blood flow in the tumor can make accurate diagnosis and differential diagnosis, this method can be complement each other with CT and MRI to improve the rate of accuracy on the staging of bladder cancer. (authors)

  1. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience.

    Science.gov (United States)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80 each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. • Automatic spectral imaging protocol selection provides appropriate scan protocols. • Abdominal CT is feasible using spectral imaging and 300 mgI/kg contrast agent. • 50-keV monochromatic images with 50 % ASIR provide optimal image quality.

  2. Computed tomography of the cervical spine with iv injection of contrast medium

    International Nuclear Information System (INIS)

    Magnaldi, S.; Pozzi-Mucelli, R.S.; Cova, M.A.; De Morpurgo, P.

    1989-01-01

    Computed Tomography (CT) without contrast medium is largely applied to the study of intervertebral disk pathology in the lumbar spine, but has not been widely accepted in cervical spine, due to technical and anatomical limitations. For these reasons many neuroradiologists still prefer myelography or myelo-CT. CT may yield better results if combined with iv contrast medium injection, which allows a better visualization of disk herniation. This technique is aimed at enhancing the density of the venous plexus which is located close to the intervertebral disk the vertebral bodies and the neural foramina. A better contrast enhancement is thus obtained between the disk and the spinal cord. The authors' experience is based on 61 patients who underwent contrast enhanced CT; in 22 cases myelography and myelo-CT were also performed. The authors describe their technique and the most frequent CT findings of disk hernation: the typical finding includes a focal hypodensity surrounded by a linear blush, due to a posteriorly dislocated epidural vein. The posterior linear blush alone may be present in few cases. Contrast enhanced CT is very useful in the study of disk pathology of the cervical spine, even when compared with myelography and myelo-CT, due the increase in the density of epidural plexus it allows. However, the technique must be very accurate if the same results as those of myelo-CT are to be obtained

  3. Dynamic Contrast-Enhanced Ultrasound of Colorectal Liver Metastases as an Imaging Modality for Early Response Prediction to Chemotherapy

    DEFF Research Database (Denmark)

    Mogensen, Marie Benzon; Hansen, Martin Lundsgaard; Henriksen, Birthe Merete

    2017-01-01

    Our aim was to investigate whether dynamic contrast-enhanced ultrasound (DCE-US) can detect early changes in perfusion of colorectal liver metastases after initiation of chemotherapy. Newly diagnosed patients with colorectal cancer with liver metastases were enrolled in this explorative prospective...... study. Patients were treated with capecitabine or 5-fluorouracil-based chemotherapy with or without bevacizumab. DCE-US was performed before therapy (baseline) and again 10 days after initiation of treatment. Change in contrast-enhancement in one liver metastasis (indicator lesion) was measured....... Treatment response was evaluated with a computed tomography (CT) scan after three cycles of treatment and the initially observed DCE-US change of the indicator lesion was related to the observed CT response. Eighteen patients were included. Six did not complete three series of chemotherapy...

  4. Contrast-enhanced voiding urosonography phantom study: intravenous iodinated and gadolinium-based contrast agents may cause false-negative results in assessment of vesicoureteral reflux in children

    International Nuclear Information System (INIS)

    Veldhoen, Simon; Sauer, Alexander; Gassenmaier, Tobias; Petritsch, Bernhard; Herz, Stefan; Blanke, Philipp; Bley, Thorsten A.; Wirth, Clemens; Derlin, Thorsten

    2015-01-01

    Contrast-enhanced voiding urosonography (ce-VUS) is commonly requested simultaneously to other diagnostic imaging necessitating intravenous contrast agents. To date there is limited knowldedge about intravesical interactions between different types of contrast agents. To assess the effect of excreted intravenous iodinated and gadolinium-based contrast agents on the intravesical distribution of ultrasound contrast within contrast-enhanced voiding urosonography. Iodinated (iomeprol, iopamidol) and gadolinium-based (gadoterate meglumine) contrast agents were diluted to bladder concentration and injected into balloons filled with saline solution. CT scans were performed to assess the contrast distribution in these phantoms. Regions of interest were placed at the top and bottom side of each balloon and Hounsfield units (HU) were measured. Three other balloons were filled with saline solution and contrast media likewise. The ultrasound contrast agent sulphur hexafluoride was added and its distribution was assessed using sonography. MDCT scans showed a separation of two liquid layers in all bladder phantoms with the contrast layers located at the bottom and the saline solution at the top. Significant differences of the HU measurements at the top and bottom side were observed (P < 0.001-0.007). Following injection of ultrasound contrast agent, US showed its distribution exclusively among the saline solution. False-negative results of contrast-enhanced voiding urosonography may occur if it is performed shortly after imaging procedures requiring intravenous contrast. (orig.)

  5. In vivo microCT imaging of rodent cerebral vasculature

    International Nuclear Information System (INIS)

    Seo, Youngho; Hasegawa, Bruce H; Hashimoto, Tomoki; Nuki, Yoshitsugu

    2008-01-01

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I tube x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml -1 at 1.2 ml min -1 ) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel (∼85 μm) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid arteries and major cerebral blood vessels

  6. In vivo microCT imaging of rodent cerebral vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Youngho; Hasegawa, Bruce H [Center for Molecular and Functional Imaging, Department of Radiology, University of California, San Francisco, CA 94143 (United States); Hashimoto, Tomoki; Nuki, Yoshitsugu [Center for Cerebrovascular Research, Department of Anesthesia and Perioperative Care, University of California, San Francisco, CA 94143 (United States)], E-mail: youngho.seo@radiology.ucsf.edu

    2008-04-07

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I{sub tube} x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml{sup -1} at 1.2 ml min{sup -1}) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel ({approx}85 {mu}m) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid

  7. Localized Castleman's disease: CT and MRI findings

    International Nuclear Information System (INIS)

    Chen Zuhua; Yang Guangzhao

    2008-01-01

    Objective: To study the CT and MRI findings of localized Castleman's disease (LCD). Methods: The CT (n=7) and MRI (n=2) appearance of LCD (n=7) confirmed by pathology and operation were retrospectively analyzed. Results Hyaline-vascular type(n=6) and plasma cell type (n=1) were confirmed by pathology in LCD (n=7). They were located in middle mediastinum (n=2), hilum pulmonis (n=l), posterior mediastinum (n=3), retro-peritoneum (n=1). Hyaline-vascular type focuses in CT scanning were manifested as round shape soft tissue masses, with homogeneous density, integrity envelope, distinct margin, and chaperonage arborizing and spot calcification. Marked persistent enhancement was apparent on contrast CT. MRI findings of hyaline-vascular type (n=2) was slightly isointense or hyperintense on T 1 WI, homogeneous hyperintense on T 2 WI, similar enhancement with CT after contrast. Plasma cell type focus were unhomogeneous density with abnormity necrosis, media and unhomogeneous enhancement after contrast. Conclusion: Marked persistent enhancement of LCD would be helpful to diagnosis and differential diagnosis in Castleman's disease. (authors)

  8. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.

    Science.gov (United States)

    Anderson, N G; Butler, A P; Scott, N J A; Cook, N J; Butzer, J S; Schleich, N; Firsching, M; Grasset, R; de Ruiter, N; Campbell, M; Butler, P H

    2010-09-01

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 microA). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications.

  9. Automated Voxel-Based Analysis of Volumetric Dynamic Contrast-Enhanced CT Data Improves Measurement of Serial Changes in Tumor Vascular Biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Coolens, Catherine, E-mail: catherine.coolens@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Cancer Center and University Health Network, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario (Canada); Driscoll, Brandon [Radiation Medicine Program, Princess Margaret Cancer Center and University Health Network, Toronto, Ontario (Canada); Chung, Caroline [Radiation Medicine Program, Princess Margaret Cancer Center and University Health Network, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Shek, Tina; Gorjizadeh, Alborz [Radiation Medicine Program, Princess Margaret Cancer Center and University Health Network, Toronto, Ontario (Canada); Ménard, Cynthia [Radiation Medicine Program, Princess Margaret Cancer Center and University Health Network, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Jaffray, David [Radiation Medicine Program, Princess Margaret Cancer Center and University Health Network, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario (Canada)

    2015-01-01

    Objectives: Development of perfusion imaging as a biomarker requires more robust methodologies for quantification of tumor physiology that allow assessment of volumetric tumor heterogeneity over time. This study proposes a parametric method for automatically analyzing perfused tissue from volumetric dynamic contrast-enhanced (DCE) computed tomography (CT) scans and assesses whether this 4-dimensional (4D) DCE approach is more robust and accurate than conventional, region-of-interest (ROI)-based CT methods in quantifying tumor perfusion with preliminary evaluation in metastatic brain cancer. Methods and Materials: Functional parameter reproducibility and analysis of sensitivity to imaging resolution and arterial input function were evaluated in image sets acquired from a 320-slice CT with a controlled flow phantom and patients with brain metastases, whose treatments were planned for stereotactic radiation surgery and who consented to a research ethics board-approved prospective imaging biomarker study. A voxel-based temporal dynamic analysis (TDA) methodology was used at baseline, at day 7, and at day 20 after treatment. The ability to detect changes in kinetic parameter maps in clinical data sets was investigated for both 4D TDA and conventional 2D ROI-based analysis methods. Results: A total of 7 brain metastases in 3 patients were evaluated over the 3 time points. The 4D TDA method showed improved spatial efficacy and accuracy of perfusion parameters compared to ROI-based DCE analysis (P<.005), with a reproducibility error of less than 2% when tested with DCE phantom data. Clinically, changes in transfer constant from the blood plasma into the extracellular extravascular space (K{sub trans}) were seen when using TDA, with substantially smaller errors than the 2D method on both day 7 post radiation surgery (±13%; P<.05) and by day 20 (±12%; P<.04). Standard methods showed a decrease in K{sub trans} but with large uncertainty (111.6 ± 150.5) %. Conclusions

  10. Automated Voxel-Based Analysis of Volumetric Dynamic Contrast-Enhanced CT Data Improves Measurement of Serial Changes in Tumor Vascular Biomarkers

    International Nuclear Information System (INIS)

    Coolens, Catherine; Driscoll, Brandon; Chung, Caroline; Shek, Tina; Gorjizadeh, Alborz; Ménard, Cynthia; Jaffray, David

    2015-01-01

    Objectives: Development of perfusion imaging as a biomarker requires more robust methodologies for quantification of tumor physiology that allow assessment of volumetric tumor heterogeneity over time. This study proposes a parametric method for automatically analyzing perfused tissue from volumetric dynamic contrast-enhanced (DCE) computed tomography (CT) scans and assesses whether this 4-dimensional (4D) DCE approach is more robust and accurate than conventional, region-of-interest (ROI)-based CT methods in quantifying tumor perfusion with preliminary evaluation in metastatic brain cancer. Methods and Materials: Functional parameter reproducibility and analysis of sensitivity to imaging resolution and arterial input function were evaluated in image sets acquired from a 320-slice CT with a controlled flow phantom and patients with brain metastases, whose treatments were planned for stereotactic radiation surgery and who consented to a research ethics board-approved prospective imaging biomarker study. A voxel-based temporal dynamic analysis (TDA) methodology was used at baseline, at day 7, and at day 20 after treatment. The ability to detect changes in kinetic parameter maps in clinical data sets was investigated for both 4D TDA and conventional 2D ROI-based analysis methods. Results: A total of 7 brain metastases in 3 patients were evaluated over the 3 time points. The 4D TDA method showed improved spatial efficacy and accuracy of perfusion parameters compared to ROI-based DCE analysis (P<.005), with a reproducibility error of less than 2% when tested with DCE phantom data. Clinically, changes in transfer constant from the blood plasma into the extracellular extravascular space (K trans ) were seen when using TDA, with substantially smaller errors than the 2D method on both day 7 post radiation surgery (±13%; P<.05) and by day 20 (±12%; P<.04). Standard methods showed a decrease in K trans but with large uncertainty (111.6 ± 150.5) %. Conclusions: Parametric

  11. The Incidence, Classification, and Management of Acute Adverse Reactions to the Low-Osmolar Iodinated Contrast Media Isovue and Ultravist in Contrast-Enhanced Computed Tomography Scanning.

    Science.gov (United States)

    Zhang, Bin; Dong, Yuhao; Liang, Long; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Chen, Wenbo; Li, Xinyu; Liang, Changhong; Zhang, Shuixing

    2016-03-01

    Some epidemiologic surveillance studies have recorded adverse drug reactions to radiocontrast agents. We aimed to investigate the incidence and management of acute adverse reactions (AARs) to Ultravist-370 and Isovue-370 in patients who underwent contrast-enhanced computed tomography (CT) scanning.Data from 137,473 patients were analyzed. They had undergone enhanced CT scanning with intravenous injection of Ultravist-370 or Isovue-370 during the period of January 1, 2006 to December 31, 2012 in our hospital. We investigated and classified AARs according to the American College of Radiology and the Chinese Society of Radiology (CSR) guidelines for iodinated contrast media. We analyzed risk factors for AARs and compared the AARs induced by Ultravist-370 and Isovue-370.Four hundred and twenty-eight (0.31%) patients experienced AARs, which included 330 (0.24%) patients with mild AARs, 82 (0.06%) patients with moderate AARs, and 16 (0.01%) patients with severe AARs (including 3 cases of cardiac arrest and one case of death). The incidence of AARs was higher with Ultravist-370 than with Isovue-370 (0.38% vs 0.24%, P management, the symptoms and signs of 96.5% of the AARs resolved within 24 hours without sequelae.Ultravist-370 and Isovue-370 are safe for patients undergoing enhanced CT scanning. The incidence of AARs is higher with Ultravist-370 than with Isovue-370, but this difference is limited only to the mild AARs. The incidence of AARs could be affected by multiple factors.

  12. Image fusion in dual energy computed tomography for detection of various anatomic structures - Effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Jijo, E-mail: jijopaul1980@gmail.com [Department of Diagnostic Radiology, Goethe University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Department of Biophysics, Goethe University, Max von Laue-Str.1, 60438 Frankfurt am Main (Germany); Bauer, Ralf W. [Department of Diagnostic Radiology, Goethe University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Maentele, Werner [Department of Biophysics, Goethe University, Max von Laue-Str.1, 60438 Frankfurt am Main (Germany); Vogl, Thomas J. [Department of Diagnostic Radiology, Goethe University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany)

    2011-11-15

    Objective: The purpose of this study was to evaluate image fusion in dual energy computed tomography for detecting various anatomic structures based on the effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality. Material and methods: Forty patients underwent a CT neck with dual energy mode (DECT under a Somatom Definition flash Dual Source CT scanner (Siemens, Forchheim, Germany)). Tube voltage: 80-kV and Sn140-kV; tube current: 110 and 290 mA s; collimation-2 x 32 x 0.6 mm. Raw data were reconstructed using a soft convolution kernel (D30f). Fused images were calculated using a spectrum of weighting factors (0.0, 0.3, 0.6 0.8 and 1.0) generating different ratios between the 80- and Sn140-kV images (e.g. factor 0.6 corresponds to 60% of their information from the 80-kV image, and 40% from the Sn140-kV image). CT values and SNRs measured in the ascending aorta, thyroid gland, fat, muscle, CSF, spinal cord, bone marrow and brain. In addition, CNR values calculated for aorta, thyroid, muscle and brain. Subjective image quality evaluated using a 5-point grading scale. Results compared using paired t-tests and nonparametric-paired Wilcoxon-Wilcox-test. Results: Statistically significant increases in mean CT values noted in anatomic structures when increasing weighting factors used (all P {<=} 0.001). For example, mean CT values derived from the contrast enhanced aorta were 149.2 {+-} 12.8 Hounsfield Units (HU), 204.8 {+-} 14.4 HU, 267.5 {+-} 18.6 HU, 311.9 {+-} 22.3 HU, 347.3 {+-} 24.7 HU, when the weighting factors 0.0, 0.3, 0.6, 0.8 and 1.0 were used. The highest SNR and CNR values were found in materials when the weighting factor 0.6 used. The difference CNR between the weighting factors 0.6 and 0.3 was statistically significant in the contrast enhanced aorta and thyroid gland (P = 0.012 and P = 0.016, respectively). Visual image assessment for image quality showed the highest score for the data reconstructed using the

  13. Image fusion in dual energy computed tomography for detection of various anatomic structures - Effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality

    International Nuclear Information System (INIS)

    Paul, Jijo; Bauer, Ralf W.; Maentele, Werner; Vogl, Thomas J.

    2011-01-01

    Objective: The purpose of this study was to evaluate image fusion in dual energy computed tomography for detecting various anatomic structures based on the effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality. Material and methods: Forty patients underwent a CT neck with dual energy mode (DECT under a Somatom Definition flash Dual Source CT scanner (Siemens, Forchheim, Germany)). Tube voltage: 80-kV and Sn140-kV; tube current: 110 and 290 mA s; collimation-2 x 32 x 0.6 mm. Raw data were reconstructed using a soft convolution kernel (D30f). Fused images were calculated using a spectrum of weighting factors (0.0, 0.3, 0.6 0.8 and 1.0) generating different ratios between the 80- and Sn140-kV images (e.g. factor 0.6 corresponds to 60% of their information from the 80-kV image, and 40% from the Sn140-kV image). CT values and SNRs measured in the ascending aorta, thyroid gland, fat, muscle, CSF, spinal cord, bone marrow and brain. In addition, CNR values calculated for aorta, thyroid, muscle and brain. Subjective image quality evaluated using a 5-point grading scale. Results compared using paired t-tests and nonparametric-paired Wilcoxon-Wilcox-test. Results: Statistically significant increases in mean CT values noted in anatomic structures when increasing weighting factors used (all P ≤ 0.001). For example, mean CT values derived from the contrast enhanced aorta were 149.2 ± 12.8 Hounsfield Units (HU), 204.8 ± 14.4 HU, 267.5 ± 18.6 HU, 311.9 ± 22.3 HU, 347.3 ± 24.7 HU, when the weighting factors 0.0, 0.3, 0.6, 0.8 and 1.0 were used. The highest SNR and CNR values were found in materials when the weighting factor 0.6 used. The difference CNR between the weighting factors 0.6 and 0.3 was statistically significant in the contrast enhanced aorta and thyroid gland (P = 0.012 and P = 0.016, respectively). Visual image assessment for image quality showed the highest score for the data reconstructed using the weighting factor 0

  14. Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications

    International Nuclear Information System (INIS)

    Reimer, Peter; Schneider, Guenter; Schima, Wolfgang

    2004-01-01

    Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd-EOB-DTPA, is under consideration. The purpose of this review is to provide an overview on the properties, clinical development and application of these three hepatobiliary contrast agents. Bolus injectable paramagnetic hepatobiliary contrast agents combine established features of extracellular agents with the advantages of hepatocyte specificity. The detection and characterisation of focal liver disease appears to be improved compared to unenhanced MRI, MRI with unspecific contrast agents and contrast-enhanced CT. To decrease the total time spent by a patient in the MR scanner, it is advisable to administer the agent immediately after acquisition of unenhanced T1-w MRI. After infusion or bolus injection (with dynamic FS-T1-w 2D or 3D GRE) of the contrast agent, moderately and heavily T2w images are acquired. Post-contrast T1-w MRI is started upon completion of T2-w MRI for mangafodipir trisodium and Gd-EOB-DTPA as early as 20 min following injection, while gadobenate dimeglumine scans are obtained >60 min following injection. Post-contrast acquisition techniques with near isotropic 3D pulse sequences with fat saturation parallel the technical progress made by MSCT combined with an unparalleled improvement in tumour-liver contrast. The individual decision that hepatobiliary contrast agent one uses is partly based on personal preferences. No comparative studies have been conducted comparing the advantages or disadvantages of all three agents directly against each other. (orig.)

  15. Contrast enhanced ultrasound in CT-undetermined focal liver lesions

    DEFF Research Database (Denmark)

    Sandrose, Sebastian; Karstrup, S.; Gerke, Oke

    2016-01-01

    , surgical resection, PET/CT and clinical follow-up. Results: The 78 included patients had 163 undetermined focal liver lesions, mean size 1.1 cm, range 0.1–5.3 cm. There were 18 malignant and 145 benign liver lesions, as defined by the standard of reference. In differentiating between benign vs. malignant...

  16. Contrast-Enhanced MR Imaging of Lymph Nodes in Cancer Patients

    International Nuclear Information System (INIS)

    Choi, Seung Hong; Moon, Woo Kyung

    2010-01-01

    The accurate identification and characterization of lymph nodes by modern imaging modalities has important therapeutic and prognostic significance for patients with newly diagnosed cancers. The presence of nodal metastases limits the therapeutic options, and it generally indicates a worse prognosis for the patients with nodal metastases. Yet anatomic imaging (CT and MR imaging) is of limited value for depicting small metastatic deposits in normal-sized nodes, and nodal size is a poor criterion when there is no extracapsular extension or focal nodal necrosis to rely on for diagnosing nodal metastases. Thus, there is a need for functional methods that can be reliably used to identify small metastases. Contrast-enhanced MR imaging of lymph nodes is a non-invasive method for the analysis of the lymphatic system after the interstitial or intravenous administration of contrast media. Moreover, some lymphotrophic contrast media have been developed and used for detecting lymph node metastases, and this detection is independent of the nodal size. This article will review the basic principles, the imaging protocols, the interpretation and the accuracies of contrast-enhanced MR imaging of lymph nodes in patients with malignancies, and we also focus on the recent issues cited in the literature. In addition, we discuss the results of several pre-clinical studies and animal studies that were conducted in our institution

  17. VEGFR-2 expression in HCC, dysplastic and regenerative liver nodules, and correlation with pre-biopsy Dynamic Contrast Enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Thaiss, W.M., E-mail: wolfgang.thaiss@med.uni-tuebingen.de [Eberhard Karls University, Department of Radiology, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, D-72076 Tuebingen (Germany); Kaufmann, S., E-mail: sascha.kaufmann@med.uni-tuebingen.de [Eberhard Karls University, Department of Radiology, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, D-72076 Tuebingen (Germany); Kloth, C., E-mail: christopher.kloth@med.uni-tuebingen.de [Eberhard Karls University, Department of Radiology, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, D-72076 Tuebingen (Germany); Nikolaou, K., E-mail: konstantin.nikolaou@med.uni-tuebingen.de [Eberhard Karls University, Department of Radiology, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, D-72076 Tuebingen (Germany); Bösmüller, H., E-mail: hans.boesmueller@med.uni-tuebingen.de [Eberhard Karls University, Department of Pathology, Liebermeisterstraße 8, D-72076 Tuebingen (Germany); Horger, M., E-mail: Marius.Horger@med.uni-tuebingen.de [Eberhard Karls University, Department of Radiology, Diagnostic and Interventional Radiology, Hoppe-Seyler-Str. 3, D-72076 Tuebingen (Germany)

    2016-11-15

    Highlights: • VEGFR-2-expression levels vary between HCC, dysplastic and regenerative liver nodules. • Perfusion parameters vary between these groups in blood flow, blood volume and HPI. • Strong correlations were observed between perfusion parameters and VEGFR-2-expression. • The results might influence diagnosis and therapy of anti-vascular therapeutic regimes. - Abstract: Purpose: To evaluate whether VEGFR-2-expression in hepatocellular carcinoma (HCC), dysplastic (DLN) and regenerative liver nodules (RLN) correlates with pre-histology, in vivo Dynamic Contrast Enhanced-Computed Tomography (DCE-CT) data as VEGFR-2-expression affects prognosis and therapeutic options. Materials and methods: 34 patients (63.6 ± 8.9 years, 7 females) underwent liver biopsy or surgery due to suspected HCC or dysplastic nodules after DCE-CT between 2009 and 2015 with no previous chemo- or interventional therapy. Immunohistochemistry staining for VEGFR-2 was performed using Immunoreactive-Remmele-Stegner-Score (IRS) for quantification. A 128-row CT-scanner was used for DCE-CT with assessment of perfusion parameters blood flow (BF), blood volume (BV), arterial liver perfusion (ALP), portal venous perfusion (PVP), and hepatic perfusion index (HPI). Results: Histology confirmed HCC (n = 10), DLN (n = 7) and RLN (n = 34). Mean IRS for VEGFR-2 in HCCs was 9.1 ± 3.0, 7.3 ± 1.6 for DLN and 5.2 ± 2.8 for RLN (p = 0.0004 for HCC vs. RLN). Perfusion values varied significantly between all three groups for BF and HPI (p < 0.001 and p < 0.0001) and for BV in HCC vs. RLN (p < 0.0001) and DLN vs. RLN (p = 0.0019). Strong correlations between VEGFR-2-IRS and perfusion parameters were observed for BF in HCC (r = 0.88, p < 0.01) and HPI in HCC and DLN (r = 0.85, p < 0.04; r = 0.9, p < 0.01). Conclusion: Immunostaining revealed different VEGFR-2-expression levels in HCC, dysplastic and regenerative liver nodules. Perfusion markers blood flow, blood volume and hepatic perfusion index

  18. Liposomes loaded with contrast material for image enhancement in computed tomography: work in progress

    International Nuclear Information System (INIS)

    Ryan, P.J.; Davis, M.A.; DeGaeta, L.R.; Woda, B.; Melchior, D.L.

    1984-01-01

    Large unilamellar phospholipid vesicles were prepared and loaded with various radiographic contrast media. Body CT following in vivo adminstration of these vesicles in the rat demonstrated opacification of organs associated with the reticuloendothelial system. Image enhancement in the spleen and liver was dose dependent and was linearly related within the dose range investigated. Clearance of the radiographic contrast material was complete within 24 hours. Diffuse splenic lymphoma following intraperitoneal or intrasplenic injection of lymphoma cells, and solitary lymphoma nodules following intrahepatic injection were readily detected as nonenhanced areas following injection of liposomes

  19. CT diagnosis of occipital bone pacchionian depression

    International Nuclear Information System (INIS)

    Zhu Jianguo; Xu Xiaolin

    2004-01-01

    Objective: To improve the recognition of the CT findings of occipital bone pacchionian depression, in order to avoid misdiagnosis. Methods: occipital bone pacchionian depression underwent CT with plain scan and intravenous contrast enhancement in 11 cases, and then the CT findings were analyzed. Results: Occipital bone pacchionian depression situated beside the torcular herophilia in 11 cases. The depression or bone defect were found at occipital bone inner plate, they can reach diploe or outer plate and had no enhancement after contrast injection. Conclusions: CT scans play an important role in diagnosis and differential diagnosis of occipital bone pacchionian depression

  20. Association of aortic wall thickness on contrast-enhanced chest CT with major cerebro-cardiac events.

    Science.gov (United States)

    Tresoldi, Silvia; Di Leo, Giovanni; Zoffoli, Elena; Munari, Alice; Primolevo, Alessandra; Cornalba, Gianpaolo; Sardanelli, Francesco

    2014-11-01

    There is a significant association between aortic atherosclerosis and previous major cardiovascular events. Particularly, thoracic aortic atherosclerosis is closely related to the degree of coronary and carotid artery disease. Thus, there is a rationale for screening the thoracic aorta in patients who undergo a chest computed tomography (CT) for any clinical question, in order to detect patients at increased risk of cerebro-cardiovascular (CCV) events. To estimate the association between either thoracic aortic wall thickness (AWT) or aortic total calcium score (ATCS) and CCV events. One hundred and forty-eight non-cardiac patients (78 men; 67 ± 12 years) underwent chest contrast-enhanced multidetector CT (MDCT). The AWT was measured at the level of the left atrium (AWTref) and at the maximum AWT (AWTmax). Correlation with clinical CCV patients' history was estimated. The value of AWTmax and of a semi-quantitative ATCS as a marker for CCV events was assessed using receiver-operating characteristic curve (ROC) analysis and multivariate regression analysis. Out of 148 patients, 59% reported sedentary lifestyle, 44% hypertension, 32% smoking, 23% hypercholesterolemia, 13% family history of cardiac disease, 12% diabetes, and 10% BMI ≥ 30 kg/m(2); 9% reported myocardial infarction, 8% aortic aneurism, 8% myocardial revascularization, and 2% ischemic stroke. Twenty-six percent of patients had a medium-to-high ATCS. Both AWTmax and AWTref correlated with hypertension and age (P < 0.002). At the ROC analysis, a 4.8 mm threshold was associated to a 90% specificity and an odds ratio of 6.3 (AUC = 0.735). Assuming as threshold the AWTmax median value (4.3 mm) of patients who suffered from at least one CCV event in their history, a negative predictive value of 90%, a RR of 3.6 and an OR of 6.3 were found. At the multivariate regression analysis, AWTmax was the only independent variable associated to the frequency of CCV events. Patients with increased thoracic

  1. Sensation of smell and taste during intravenous injection of iodinated contrast media in CT examinations

    Science.gov (United States)

    Yamaguchi, Naoto; Yamaguchi, Aiko; Nagasawa, Naoki; Taketomi-Takahashi, Ayako; Suto, Takayuki; Tsushima, Yoshito

    2017-01-01

    Objective: To assess the incidence and types of sensation of smell and taste during i.v. injection of five kinds of contrast media (CM) in CT examinations. Methods: 735 patients who underwent contrast-enhanced CT (CE-CT) between 14 March 2016 and 5 April 2016 were enrolled. Medical staff asked patients whether they felt heat sensation and sensation of smell and taste during i.v. injection of CM (one of the following: iopromide, iomeprol, iopamidol, iohexol and ioversol) after their CE-CT. If the patients stated having felt the sensation of smell or taste, they were also asked what kind of smell or taste they sensed. Next, 30 ml of each CM was poured into high-purity pet cups for radiological technologists to smell directly. Radiological technologists were asked whether or not each CM had any smell. Results: The sensations of smell and taste incidence for iopromide were 24.3% and 18.9%, respectively, which were significantly higher than those for other CM (p < 0.05). The highest incidence of the sensation of smell was medicine-ish, and the most frequently noted taste was bitterness. All radiological technologists could directly smell only iopromide, which has an ether group on a side chain and fewer hydroxyl groups. Conclusion: Iopromide showed a higher incidence of sensation of smell and taste than other CM. Advances in knowledge: This was the first investigation of sensation of smell and taste during i.v. injection of CM, and a specific CM showed a higher incidence, which is suspected to be due to its chemical structure. PMID:27805431

  2. CT findings of medulloblastoma

    International Nuclear Information System (INIS)

    Tsuchida, Tadashi; Fukuda, Mitsunori; Takeda, Norio; Tanaka, Ryuichi; Ito, Jusuke.

    1982-01-01

    Computed tomography (CT) of ten patients with medulloblastomas was evaluated. Six of them showed solid, nearly homogeneous lesions and a definite enhancement after the infusion of the contrast medium. However, 4 cases showed heterogenous mass lesions composed of areas of a low density and an iso- or slightly high density which was attenuated by contrast enhancement. Histological examinations revealed differentiated medulloblastomas in two of them, but the other two cases were typical medulloblastomas. It should be remembered that medulloblastomas can reveal heterogenous cerebellar midline mass lesions in CT scans. (author)

  3. Contrast-enhanced computed tomography of the gastrointestinal tract in clinically normal alpacas and llamas.

    Science.gov (United States)

    Stieger-Vanegas, Susanne M; Cebra, Christopher K

    2013-01-15

    To assess the feasibility and usefulness of CT enterography to evaluate the gastrointestinal tract in clinically normal llamas and alpacas. Prospective observational study. 7 clinically normal alpacas and 8 clinically normal llamas. The imaging protocol included orogastric administration of iodinated contrast material mixed with water. Three hours later, helical CT scanning was performed of the entire abdomen with transverse and multiplanar sagittal and dorsal projections before and after IV iodinated contrast agent injection. Both oral and IV contrast agents were well tolerated, and no adverse reactions were observed. Transverse images depicted the gastrointestinal tract and pancreas in the short axis; however, dorsal and sagittal projections aided in localizing and differentiating the various gastrointestinal segments, including the pancreas. In all camelids, the wall of the gastrointestinal tract was well differentiated. In all but 2 camelids, all gastrointestinal segments were well visualized and differentiated. In those 2 animals, the cecum was difficult to identify. Good distention of the small intestine was achieved by use of the oral contrast agent. The dorsal projections were useful to identify the pancreas in its entire length. The present study supplied new information about gastrointestinal wall thickness, intestinal diameter, and location of the pancreas and ileocecocolic junction in alpacas and llamas. Multiplanar contrast-enhanced CT was useful to reveal the various segments of the gastrointestinal tract, pancreas, and abdominal lymph nodes. The shorter time delay before imaging, compared with the delay with conventional barium studies, makes this technique complementary or superior to conventional radiographic or ultrasonographic studies for evaluation of the gastrointestinal tract.

  4. CT findings of adrenal schwannoma

    International Nuclear Information System (INIS)

    Zhang, Y.-M.; Lei, P.-F.; Chen, M.-N.; Lv, X.-F.; Ling, Y.-H.; Cai, P.-Q.; Gao, J.-M.

    2016-01-01

    Aim: To analyse the computed tomography (CT) imaging features of patients with adrenal schwannoma. Materials and methods: Eight cases of adrenal schwannoma confirmed by histopathology were included in this study. All eight patients had undergone multiphase CT examinations. The features of the adrenal schwannoma in the CT images were analysed retrospectively in detail, including size, shape, margin, radiodensity, calcification, and enhancement pattern. Results: There were six male and two female patients, with a median age of 44.5 years (range, 25–52 years). Two patients complained of right flank pain, and two with left upper abdominal discomfort, while the remaining patients were diagnosed by routine ultrasound examinations. On unenhanced CT images, all cases of adrenal schwannoma were well circumscribed, rounded or oval, heterogeneous masses with cystic components, with two cases exhibiting calcification, and three cases with septa. On enhanced CT images, all cases displayed mild heterogeneous enhancement of the tumour during the arterial phase, and progressive enhancement during the portal venous phase and equilibrium phase. Conclusion: Adrenal schwannoma commonly presents as a well-defined unilateral mass with cystic degeneration, septa, and a characteristic progressive contrast-enhancement pattern on multiphase enhanced scans. - Highlights: • Adrenal schwannomas were extremely rare, and eight cases' medical data of this disease were collected in this study. • They usually presented a well-defined unilateral mass with cystic degeneration and sepations. • They manifested characteristic progressive contrast enhancement pattern on enhanced CT images.

  5. Contrast-enhanced ultrasound and computed tomography findings of recurrent ovarian steroid cell tumor presenting with peritoneal seeding: A case report

    International Nuclear Information System (INIS)

    Im, A Lan; Lee, Young Hwan; Kim, Hye Won; Lee, Han Ah; Choi, Keum Ha

    2013-01-01

    We present ultrasonography and computed tomography (CT) findings of a case of recurrent ovarian steroid cell tumor presenting with peritoneal seeding in a 45-year-old woman. On abdominal ultrasonography, there were multiple hypoechoic round masses in the peritoneal cavity including the perihepatic area. Contrast-enhanced ultrasonography showed intense homogenous enhancement on the arterial phase and delayed prolonged enhancement of the masses. CT revealed multiple peritoneal solid masses with strong enhancement. Five years ago, the patient had been diagnosed with a steroid cell tumor of the left ovary. At that time, the CT showed a well-enhancing, lobulating, large solid mass at the left adnexa. Imaging findings of the peritoneal masses suggested peritoneal seeding from the preexisting ovarian steroid cell tumor. For treatment of the metastatic lesions in the perihepatic area, ultrasonography-guided radiofrequency ablation (RFA) was performed, and debulking surgery for the peritoneal masses was done. Six months later, complete ablation of the perihepatic metastases by RFA and a marked decrease in the peritoneal metastases by surgery were found on the follow-up CT.

  6. Multi-modality PET-CT imaging of breast cancer in an animal model using nanoparticle x-ray contrast agent and 18F-FDG

    Science.gov (United States)

    Badea, C. T.; Ghaghada, K.; Espinosa, G.; Strong, L.; Annapragada, A.

    2011-03-01

    Multi-modality PET-CT imaging is playing an important role in the field of oncology. While PET imaging facilitates functional interrogation of tumor status, the use of CT imaging is primarily limited to anatomical reference. In an attempt to extract comprehensive information about tumor cells and its microenvironment, we used a nanoparticle xray contrast agent to image tumor vasculature and vessel 'leakiness' and 18F-FDG to investigate the metabolic status of tumor cells. In vivo PET/CT studies were performed in mice implanted with 4T1 mammary breast cancer cells.Early-phase micro-CT imaging enabled visualization 3D vascular architecture of the tumors whereas delayedphase micro-CT demonstrated highly permeable vessels as evident by nanoparticle accumulation within the tumor. Both imaging modalities demonstrated the presence of a necrotic core as indicated by a hypo-enhanced region in the center of the tumor. At early time-points, the CT-derived fractional blood volume did not correlate with 18F-FDG uptake. At delayed time-points, the tumor enhancement in 18F-FDG micro-PET images correlated with the delayed signal enhanced due to nanoparticle extravasation seen in CT images. The proposed hybrid imaging approach could be used to better understand tumor angiogenesis and to be the basis for monitoring and evaluating anti-angiogenic and nano-chemotherapies.

  7. Budd-Chiari syndrome: dynamic enhancement findings with multi-slice helical CT and CT angiography analysis

    International Nuclear Information System (INIS)

    Meng Xiaochun; Shan Hong; Zhu Kangshun; Xu Chuan; Zhang Jiansheng; Liu Lingyun; Ye Binbin

    2005-01-01

    Objective: To investigate the dynamic enhancement regulations of liver and their mechanism in Budd-Chiari syndrome (BCS) by using multi-slice CT and evaluate the value of CT angiography in the diagnosis of BCS. Methods: 28 cases with BCS confirmed by digital subtraction angiography (DSA) were retrospectively analyzed. All patients underwent dynamic enhancement examinations with multi-slice CT within 1 week before DSA. The relevant vessels were reconstructed respectively with MIP, VR and MPR. Compared with the results of DSA, we analyzed the dynamic enhancement regulations of liver in BCS, estimated the value of dynamic enhancement CT exams and CTA techniques in judging the obstruction level and showing collateral vessels. Results: Of all 28 cases, CT correctly showed the obstruction level in 26 cases, and 2 had incorrect results which proved to be membranous obstruction of the inferior vena cava superior to diaphragm. In 22 cases with hepatic vein obstructions, hepatic parenchyma displayed typical patchy enhancement in 19, atypical patchy enhancement in 3.8 cases among these showed benign nodules. Simultaneously, CT showed stenosis and rigidity of portal vein branches in 20, enlargement of hepatic artery in 14, hepatic collateral vessels in 20 out of 22 cases. In 6 cases with simple obstruction of inferior vena cava, hepatic changes were not found. Collateral circulations in or out of liver corresponded to the obstruction level. Conclusion: Dynamic enhancement examinations with multi-slice CT can correctly reflect the hepatic hemodynamic changes. Transverse images, combined with CTA, can explicitly display the obstruction level of vascular lesions and collateral circulations in BCS. (authors)

  8. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang [The First Affiliated Hospital of Zhengzhou University, Department of Radiology, Zhengzhou, Henan Province (China)

    2017-01-15

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80) each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. (orig.)

  9. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

    International Nuclear Information System (INIS)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80) each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. (orig.)

  10. Enhanced transbuccal salmon calcitonin (sCT) delivery: effect of chemical enhancers and electrical assistance on in vitro sCT buccal permeation.

    Science.gov (United States)

    Oh, Dong-Ho; Chun, Kyeung-Hwa; Jeon, Sang-Ok; Kang, Jeong-Won; Lee, Sangkil

    2011-10-01

    This study investigates the combined effect of absorption enhancers and electrical assistance on transbuccal salmon calcitonin (sCT) delivery, using fresh swine buccal tissue. We placed 200 IU (40 μg/mL) of each sCT formulation--containing various concentrations of ethanol, N-acetyl-L-cysteine (NAC), and sodium deoxyglycocholate (SDGC)--onto the donor part of a Franz diffusion cell. Then, 0.5 mA/cm(2) of fixed anodal current was applied alone or combined with chemical enhancers. The amount of permeated sCT was analyzed using an ELISA kit, and biophysical changes of the buccal mucosa were investigated using FT-IR spectroscopy, and hematoxylin-eosin staining methods were used to evaluate histological alteration of the buccal tissues. The flux (J(s)) of sCT increased with the addition of absorption enhancer groups, but it was significantly enhanced by the application of anodal iontophoresis (ITP). FT-IR study revealed that all groups caused an increase in lipid fluidity but only the groups containing SDGC showed statistically significant difference. Although the histological data of SDGC groups showed a possibility for tissue damage, the present enhancing methods appear to be safe. In conclusion, the combination of absorption enhancers and electrical assistance is a potential strategy for the enhancement of transbuccal sCT delivery. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. An investigation into current protocols and radiographer opinions on contrast extravasation in Irish CT departments

    International Nuclear Information System (INIS)

    Cleary, N.; McNulty, J.P.; Foley, S.J.; Kelly, E.

    2017-01-01

    Background: Iodinated contrast extravasation is a serious complication associated with intravenous administration in radiology. Departmental protocols and the radiographer's approach on both prevention techniques and treatment will affect the prevalence of extravasation, and the eventual outcome for the patient when it does occur. Aims: To examine contrast extravasation protocols in place in Irish CT departments for alignment with European Society of Urogenital Radiology (ESUR) Guidelines (2014); to establish radiographer's opinions on contrast extravasation; and to examine radiographer adherence to protocols. Methods: Contrast extravasation protocols from a purposively selected sample of CT departments across Ireland (n = 6) were compared to ESUR guidelines, followed by an online survey of CT radiographers practicing in the participating centres. Results: All participating CT departments (n = 5) had written protocols in place. High risk patients, such as elderly or unconscious, were identified in most protocols, however, children were mentioned in just one protocol and obese patients were not specified in any. The response rate of CT radiographers was 23% (n = 24). 58% (n = 14) of respondents indicated that contrast extravasation was more likely during CTA examinations. While high levels of confidence in managing extravasation were reported, suggested treatment approaches, and confidence in same, was more variable. Clinical workload in CT departments was also identified as a factor impacting on patient care and management. Conclusion: While contrast extravasation protocols were generally in line with ESUR Guidelines, high risk patients may not be getting sufficient attention. More radiographer awareness of patient monitoring needs, particularly in busy departments with a heavy workload may also reduce extravasation risk, and improve management of same. - Highlights: • Irish protocols on contrast extravasation are generally in line with

  12. Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study

    International Nuclear Information System (INIS)

    Karlo, Christoph; Lauber, Arno; Goetti, Robert Paul; Baumueller, Stephan; Stolzmann, Paul; Scheffel, Hans; Desbiolles, Lotus; Marincek, Borut; Leschka, Sebastian; Schmidt, Bernhard; Alkadhi, Hatem

    2011-01-01

    To differentiate proxy renal cystic lesions containing protein, blood, iodine contrast or saline solutions using dual-energy CT (DECT) equipped with a new tin filter technology (TFT). 70 proxies (saline, protein, blood and contrast agent) were placed in unenhanced and contrast-enhanced kidney phantoms. DECT was performed at 80/140 kV with and without tin filtering. Two readers measured the CT attenuation values in all proxies twice. An 80/140 kV ratio was calculated. All intra- and interobserver agreements were excellent (r = 0.93-0.97; p 0.05). The CT attenuation of protein, blood and contrast agent solution differed significantly with tin filtering (p < 0.01-0.05). Significant differences were found between the ratios of protein and blood compared to contrast medium solution (each, p < 0.05) and between the ratios of protein and blood in both phantoms with tin filtering (each, p < 0.05). DECT allows discrimination between a proxy renal lesion containing contrast agent and lesions containing protein and blood through their different attenuation at 80 kV and 140 kV. Further discrimination between protein and blood containing proxies is possible when using a tin filter. (orig.)

  13. The study of two methods for high pressure injection in CT enhancement to display the aortic dissecting aneurysm

    International Nuclear Information System (INIS)

    Wang Yang; Zhu Bin; Zhang Zhen

    2008-01-01

    Objective: To discuss the consequences of two different methods of high pressure injection in CT contrast enhancement to display the aortic dissecting aneurysm. Methods: 100 patients underwent Lightspeed 16 MS CT with contrast enhancement of Stellant D high pressure injector (Medrad), injecting speed of 4.0 mL/s and 80 ml dosage of contrast medium. All patients were divided into A and B groups with 50 in each. The single high pressure injection was applied to A group without isotonic Na chloride flush. B group underwent the same high pressure injection and followed by isotonic Na chloride flush. The method of evaluation was carried out by double blind observation. Results: A group revealed radiologic artifact up to 40 cases with positive rate of 80%. B group demonstrated the same kind of radiologic artifact in 26 cases with positive rate of 52%. Conclusions: Using normal saline (sodium chloride solution)flush after high pressure injection of contrast medium during MSCT angiography is obviously better to demonstrate the internal structures of treatvessels. (authors)

  14. Use of contrast-enhanced ultrasonography in hepatosplenic sarcoidosis: Report of 2 cases

    International Nuclear Information System (INIS)

    Grzelak, Piotr; Augsburg, Lukasz; Majos, Agata; Stefanczyk, Ludomir; Gorski, Paweł; Piotrowski, Wojciech; Antczak, Adam

    2012-01-01

    Sarcoidosis is a multisystemic granulomatous disease of unknown etiology that predominantly affects lungs and intrathoracic lymph nodes; in rare cases (approx. 10%), infiltration of the spleen and liver may be observed. In order to identify hepatosplenic infiltration, MRI/CT of the abdomen and different ultrasound techniques (PD US, US D) are usually performed. Contrast enhanced ultrasound (CEUS) is a new technique in this diagnostic algorithm, but the fact that this is a safe, accurate, and widely available method opens a new perspective for the detection of abdominal lesions in sarcoidosis. We report 2 cases of hepatosplenic sarcoidosis – a 41-year-old woman with splenic lesions and a 46-year-old man with liver infiltration. On the basis of these 2 cases we intended to show the diagnostic potential of contrast enhanced ultrasound for the recognition of focal lesions of the spleen and liver in patients suffering from sarcoidosis

  15. Dual-contrast agent photon-counting computed tomography of the heart: initial experience.

    Science.gov (United States)

    Symons, Rolf; Cork, Tyler E; Lakshmanan, Manu N; Evers, Robert; Davies-Venn, Cynthia; Rice, Kelly A; Thomas, Marvin L; Liu, Chia-Ying; Kappler, Steffen; Ulzheimer, Stefan; Sandfort, Veit; Bluemke, David A; Pourmorteza, Amir

    2017-08-01

    To determine the feasibility of dual-contrast agent imaging of the heart using photon-counting detector (PCD) computed tomography (CT) to simultaneously assess both first-pass and late enhancement of the myocardium. An occlusion-reperfusion canine model of myocardial infarction was used. Gadolinium-based contrast was injected 10 min prior to PCD CT. Iodinated contrast was infused immediately prior to PCD CT, thus capturing late gadolinium enhancement as well as first-pass iodine enhancement. Gadolinium and iodine maps were calculated using a linear material decomposition technique and compared to single-energy (conventional) images. PCD images were compared to in vivo and ex vivo magnetic resonance imaging (MRI) and histology. For infarct versus remote myocardium, contrast-to-noise ratio (CNR) was maximal on late enhancement gadolinium maps (CNR 9.0 ± 0.8, 6.6 ± 0.7, and 0.4 ± 0.4, p contrast agent cardiac imaging is feasible with photon-counting detector CT. These initial proof-of-concept results may provide incentives to develop new k-edge contrast agents, to investigate possible interactions between multiple simultaneously administered contrast agents, and to ultimately bring them to clinical practice.

  16. Long Distance Endovascular Growth of Jugulotympanic Paraganglioma Evident in 68Ga-DOTATATE PET but Concealed on CT.

    Science.gov (United States)

    Avramovic, Nemanja; Weckesser, Matthias; Velasco, Aglaé; Stenner, Markus; Noto, Benjamin

    2017-02-01

    A 60-year-old woman was referred to contrast-enhanced CT for evaluation of jugular vein thrombosis incidentally detected by ultrasound. Contrast-enhanced CT showed an enhanced tumor of the right skull base highly suspicious of jugulotympanic paraganglioma. However, the jugular veins showed a nearly symmetric contrast enhancement without clear evidence of thrombosis. Consecutive Ga-DOTATATE PET/CT depicted high tumor uptake, which comprised the entire internal jugular vein. Endovascular growth of paraganglioma might be missed on contrast-enhanced CT because of high vascularization of the lesion. Ga-DOTATATE PET is suited for accurate determination of tumor extent.

  17. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Rajaram, Smitha [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Academic Unit of Radiology, C Floor, Royal Hallamshire Hospital, Sheffield (United Kingdom); Swift, Andrew J.; Wild, Jim M. [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Capener, David; Telfer, Adam [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Davies, Christine; Hill, Catherine [Sheffield Teaching Hospitals Trust, Department of Radiology, Sheffield (United Kingdom); Condliffe, Robin; Elliot, Charles; Kiely, David G. [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Hurdman, Judith [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom)

    2012-02-15

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  18. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Rajaram, Smitha; Swift, Andrew J.; Wild, Jim M.; Capener, David; Telfer, Adam; Davies, Christine; Hill, Catherine; Condliffe, Robin; Elliot, Charles; Kiely, David G.; Hurdman, Judith

    2012-01-01

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  19. CT fogging effect with ischemic cerebral infarcts

    International Nuclear Information System (INIS)

    Becker, H.; Desch, H.; Hacker, H.; Pencz, A.; Frankfurt Univ.

    1979-01-01

    Systematic CT studies on ten patients with persistent ischemic cerebral infarct revealed a constant phenomenon, the fogging effect. The hypodense infarct at the beginning will be isodense, or close to isodense, on the plain CT during the second or third week and at a later stage will be hypodense again. The fogging infarcted area shows homogeneous intensive contrast enhancement. Knowledge of the fogging effect is important for correct interpretation of the CT image and the indication for contrast medium CT. CT without contrast medium may lead to misinterpretation during the second and third week after the onset of cerebral infarction. (orig.) [de

  20. CT fogging effect with ischemic cerebral infarcts

    Energy Technology Data Exchange (ETDEWEB)

    Becker, H; Desch, H; Hacker, H; Pencz, A [Frankfurt Univ. (Germany, F.R.). Abt. fuer Neurologie; Frankfurt Univ. (Germany, F.R.). Abt. fuer Neuroradiologie)

    1979-01-01

    Systematic CT studies on ten patients with persistent ischemic cerebral infarct revealed a constant phenomenon, the fogging effect. The hypodense infarct at the beginning will be isodense, or close to isodense, on the plain CT during the second or third week and at a later stage will be hypodense again. The fogging infarcted area shows homogeneous intensive contrast enhancement. Knowledge of the fogging effect is important for correct interpretation of the CT image and the indication for contrast medium CT. CT without contrast medium may lead to misinterpretation during the second and third week after the onset of cerebral infarction.

  1. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    International Nuclear Information System (INIS)

    Hausegger, K.; Reinprecht, P.; Kau, T.; Igerc, I.; Lind, P.

    2005-01-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk registered , which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk registered can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  2. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, K.; Reinprecht, P. [Roentgendiagnostisches Zentralinstitut, LKH Klagenfurt (Austria); Kau, T. [Roentgendiagnostisches Zentral Inst., Klagenfurt (Austria); Igerc, I.; Lind, P. [Abt. fuer Nuklearmedizin und Spezielle Endokrinologie, LKH Klagenfurt (Austria)

    2005-06-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk {sup registered}, which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk {sup registered} can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  3. Diagnostic value of delayed washout rate of contrast-enhanced multi ...

    African Journals Online (AJOL)

    Rania Essameldein Mohamed

    2013-12-18

    Dec 18, 2013 ... On the other hand, CT contrast washout rate tests are more useful ..... with multidetector CT: pathologic conditions, pearls, and pitfalls. RadioGraphics 2009 ... advances in genetics, diagnosis, localization and treatment.

  4. The Application of Contrast Media for In Vivo Feature Enhancement in X-Ray Computed Tomography of Soil-Grown Plant Roots.

    Science.gov (United States)

    Keyes, Samuel D; Gostling, Neil J; Cheung, Jessica H; Roose, Tiina; Sinclair, Ian; Marchant, Alan

    2017-06-01

    The use of in vivo X-ray microcomputed tomography (μCT) to study plant root systems has become routine, but is often hampered by poor contrast between roots, soil, soil water, and soil organic matter. In clinical radiology, imaging of poorly contrasting regions is frequently aided by the use of radio-opaque contrast media. In this study, we present evidence for the utility of iodinated contrast media (ICM) in the study of plant root systems using μCT. Different dilutions of an ionic and nonionic ICM (Gastrografin 370 and Niopam 300) were perfused into the aerial vasculature of juvenile pea plants via a leaf flap (Pisum sativum). The root systems were imaged via μCT, and a variety of image-processing approaches used to quantify and compare the magnitude of the contrast enhancement between different regions. Though the treatment did not appear to significantly aid extraction of full root system architectures from the surrounding soil, it did allow the xylem and phloem units of seminal roots and the vascular morphology within rhizobial nodules to be clearly visualized. The nonionic, low-osmolality contrast agent Niopam appeared to be well tolerated by the plant, whereas Gastrografin showed evidence of toxicity. In summary, the use of iodine-based contrast media allows usually poorly contrasting root structures to be visualized nondestructively using X-ray μCT. In particular, the vascular structures of roots and rhizobial nodules can be clearly visualized in situ.

  5. Intraarterial CT Angiography Using Ultra Low Volume of Iodine Contrast – Own Experiences

    International Nuclear Information System (INIS)

    Garcarek, Jerzy; Kurcz, Jacek; Guziński, Maciej; Banasik, Mirosław; Miś, Marcin; Gołębiowski, Tomasz

    2015-01-01

    High volume of intravenous contrast in CT-angiography may result in contrast-induced nephropathy. Intraarterial ultra-low volume of contrast medium results in its satisfactory blood concentration with potentially good image quality. The first main purpose was to assess the influence of the method on function of transplanted kidney in patients with impaired graft function. The second main purpose of the study was to evaluate the usefulness of this method for detection of gastrointestinal and head-and-neck haemorrhages. Between 2010 and 2013 intraarterial CT-angiography was performed in 56 patients, including 28 with chronic kidney disease (CKD). There were three main subgroups: 18 patients after kidney transplantation, 10 patients with gastrointestinal hemorrhage, 8 patients with head-and-neck hemorrhage. Contralateral or ipsilateral inguinal arterial approach was performed. The 4-French vascular sheaths and 4F-catheters were introduced under fluoroscopy. Intraarterial CT was performed using 64-slice scanner. The scanning protocol was as follows: slice thickness 0.625 mm, pitch 1.3, gantry rotation 0.6 sec., scanning delay 1–2 sec. The extent of the study was established on the basis of scout image. In patients with CKD 6–8 mL of Iodixanol (320 mg/mL) diluted with saline to 18–24 mL was administered at a speed of 4–5 mL/s. Vasculature was properly visualized in all patients. In patients with impaired renal function creatinine/eGFR levels remained stable in all but one case. Traditional arteriography failed and CT-angiography demonstrated the site of bleeding in 3 of 10 patients with symptoms of gastrointestinal bleeding (30%). In 8 patients with head-and-neck bleeding CT-angiography did not prove beneficial when compared to traditional arteriography. 1. Ultra-low contrast intraarterial CT-angiography does not deteriorate the function of transplanted kidneys in patients with impaired graft function. 2. 3D reconstructions allow for excellent visualization of

  6. Low tube voltage and low contrast material volume cerebral CT angiography

    International Nuclear Information System (INIS)

    Luo, Song; Zhang, Long Jiang; Lu, Guang Ming; Meinel, Felix G.; McQuiston, Andrew D.; Zhou, Chang Sheng; Qi, Li; Schoepf, U.J.

    2014-01-01

    To evaluate the image quality, radiation dose and diagnostic accuracy of low kVp and low contrast material volume cerebral CT angiography (CTA) in intracranial aneurysm detection. One hundred twenty patients were randomly divided into three groups (n = 40 for each): Group A, 70 ml iodinated contrast agent/120 kVp; group B, 30 ml/100 kVp; group C, 30 ml/80 kVp. The CT numbers, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured in the internal carotid artery (ICA) and middle cerebral artery (MCA). Subjective image quality was evaluated. For patients undergoing DSA, diagnostic accuracy of CTA was calculated with DSA as reference standard and compared. CT numbers of ICA and MCA were higher in groups B and C than in group A (P < 0.01). SNR and CNR in groups A and B were higher than in group C (both P < 0.05). There was no difference in subjective image quality among the three groups (P = 0.939). Diagnostic accuracy for aneurysm detection among these groups had no statistical difference (P = 1.00). Compared with group A, the radiation dose of groups B and C was decreased by 45 % and 74 %. Cerebral CTA at 100 or 80 kVp using 30 ml contrast agent can obtain diagnostic image quality with a low radiation dose while maintaining the same diagnostic accuracy for aneurysm detection. (orig.)

  7. CT imaging features of anaplastic thyroid carcinoma

    International Nuclear Information System (INIS)

    Shi Zhenshan; You Ruixiong; Cao Dairong; Li Yueming; Zhuang Qian

    2013-01-01

    Objective: To investigate the CT characteristics of anaplastic thyroid carcinoma and evaluate the diagnostic value of CT in this disease. Methods: The CT findings of 10 patients with pathologically proved anaplastic thyroid carcinoma were retrospectively reviewed. The patients included 7 females and 3 males. Their age ranged from 25.0 to 78 years with median of 61 years. Multi-slices plain and post contrast CT scans were performed in all patients. Results: Unilateral thyroid was involved in 6 patients. Unilateral thyroid and thyroid isthmus were both involved in 2 patients due to big size. Bilateral thyroid were involved in 2 patients. The maximum diameter of anaplastic thyroid carcinoma ranged from 2.9-12.8 cm with mean of (4.5 ± 1.4) cm. All lesions demonstrated unclear margins and envelope invasion. The densities of all lesions were heterogeneous and obvious necrosis areas were noted on precontrast images. Seven lesions showed varied calcifications, and coarse granular calcifications were found in 5 lesions among them. All lesions showed remarkable heterogenous enhancement on post-contrast CT. The CT value of solid portion of the tumor increased 40 HU after contrast media administration. The ratios of CT value which comparing of the tumor with contralateral sternocleidomastoid muscle were 0.69-0.82 (0.76 ± 0.18) and 1.25-1.41 (1.33 ± 0.28) on pre and post CT, respectively. Enlarged cervical lymph nodes were found in 6 cases (60.0%). It showed obvious homogeneous enhancement or irregular ring-like enhancement on post-contrast images and dot calcifications were seen in 1 case. Conclusions: Relative larger single thyroid masses with coarse granular calcifications, necrosis,envelope invasion, remarkable heterogeneous enhancing and enlarged lymph nodes on CT are suggestive of anaplastic thyroid carcinoma. (authors)

  8. Characterizing EPR-mediated passive drug targeting using contrast-enhanced functional ultrasound imaging.

    Science.gov (United States)

    Theek, Benjamin; Gremse, Felix; Kunjachan, Sijumon; Fokong, Stanley; Pola, Robert; Pechar, Michal; Deckers, Roel; Storm, Gert; Ehling, Josef; Kiessling, Fabian; Lammers, Twan

    2014-05-28

    The Enhanced Permeability and Retention (EPR) effect is extensively used in drug delivery research. Taking into account that EPR is a highly variable phenomenon, we have here set out to evaluate if contrast-enhanced functional ultrasound (ceUS) imaging can be employed to characterize EPR-mediated passive drug targeting to tumors. Using standard fluorescence molecular tomography (FMT) and two different protocols for hybrid computed tomography-fluorescence molecular tomography (CT-FMT), the tumor accumulation of a ~10 nm-sized near-infrared-fluorophore-labeled polymeric drug carrier (pHPMA-Dy750) was evaluated in CT26 tumor-bearing mice. In the same set of animals, two different ceUS techniques (2D MIOT and 3D B-mode imaging) were employed to assess tumor vascularization. Subsequently, the degree of tumor vascularization was correlated with the degree of EPR-mediated drug targeting. Depending on the optical imaging protocol used, the tumor accumulation of the polymeric drug carrier ranged from 5 to 12% of the injected dose. The degree of tumor vascularization, determined using ceUS, varied from 4 to 11%. For both hybrid CT-FMT protocols, a good correlation between the degree of tumor vascularization and the degree of tumor accumulation was observed, within the case of reconstructed CT-FMT, correlation coefficients of ~0.8 and p-values of EPR, and potentially also to pre-select patients likely to respond to passively tumor-targeted nanomedicine treatments. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. CT features of renal epithelioid angiomyolipomas

    International Nuclear Information System (INIS)

    Hu Xiaoyun; Fang Xiangming; Hu Chunhong; Chen Hongwei; Cui Lei; Bao Jian; Yao Xuanjun

    2010-01-01

    Objective: To explore the CT and pathological features of renal epithelioid angiomyolipoma (EAML). Methods: Clinical data and CT images from ten cases with EAML proved by surgery and pathology were retrospectively analyzed. All cases were performed with plain and contrast enhanced CT scans. Results: CT features: higher pre-contrasted density than kidney, bulging from kidney, absent of fat, markedly heterogeneous enhancement (quick wash-in and slow wash-out), big size without lobular sign, complete capsule with clear margin and mild necrostic area. Pathological features: diffuse sheets of epithelioid cells were found under microscopy with immunohistochemistrical findings including positivity for HMB-45 and negativity for EMA. Conclusion: Some specific CT features, which is correlated well with the pathological findings, provide helpful information in the primary diagnosis of EAML. (authors)

  10. Delayed contrast-enhanced computed tomography in patients with known or suspected cardiac sarcoidosis: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Aikawa, Tadao; Naya, Masanao; Obara, Masahiko [Hokkaido University Graduate School of Medicine, Sapporo (Japan); Oyama-Manabe, Noriko; Kudo, Kohsuke [Hokkaido University Hospital, Department of Diagnostic and Interventional Radiology, Sapporo (Japan); Ohira, Hiroshi; Sugimoto, Ayako; Tsujino, Ichizo [Hokkaido University Graduate School of Medicine, First Department of Medicine, Sapporo (Japan); Manabe, Osamu; Tamaki, Nagara [Hokkaido University Graduate School of Medicine, Department of Nuclear Medicine, Sapporo (Japan); Tsutsui, Hiroyuki [Kyushu University, Department of Cardiovascular Medicine, Fukuoka (Japan)

    2017-10-15

    To evaluate the diagnostic value of delayed contrast-enhanced computed tomography (DE-CT) for cardiac sarcoidosis (CS) in patients with or without implantable devices, including a quantitative comparison with late gadolinium enhancement cardiac magnetic resonance (LGE-CMR). Twenty-four patients (mean age, 64 ± 9 years; 17 women) with known or suspected CS underwent retrospective electrocardiogram-gated DE-CT at 80 kV with knowledge-based iterative model reconstruction. Fourteen patients without implantable devices also underwent LGE-CMR, while ten with pacemakers or implantable cardioverter-defibrillators did not. The presence of hyperenhanced myocardium was assessed visually and quantitatively using a 5-standard deviation threshold above the mean of remote myocardium. Inter-observer agreement for visual detection of hyperenhanced segments on DE-CT was excellent in patients with implantable devices and in those without (κ = 0.91 and κ = 0.94, respectively). Comparisons of the percent area of hyperenhanced myocardium between DE-CT and LGE-CMR on both per-patient and per-segment analyses showed good correlations (r = 0.96 and r = 0.83, respectively; p < 0.001). The sensitivity and specificity of DE-CT for the diagnosis of CS were 94% and 33%. The extent of hyperenhanced lesion with DE-CT showed good agreement with LGE-CMR results. DE-CT showed high sensitivity for detecting CS and may be useful particularly in patients with contraindications to CMR. (orig.)

  11. Vascular patterns in nodules of intraductal papillary mucinous neoplasms depicted under contrast-enhanced ultrasonography are helpful for evaluating malignant potential

    International Nuclear Information System (INIS)

    Kurihara, Naoko; Kawamoto, Hirofumi; Kobayashi, Yoshiyuki; Okamoto, Yuko; Yamamoto, Naoki; Tsutsumi, Koichiro; Fujii, Masakuni; Kato, Hironari; Yamamoto, Kazuhide

    2012-01-01

    Objectives: The purpose of this study is to evaluate the feasibility of contrast-enhanced ultrasonography (CE-US) to differentiate between benign and malignant intraductal papillary mucinous neoplasms (IPMN). Patients and methods: Contrast-enhanced ultrasonography with a contrast agent was performed on 22 consecutive patients with IPMN suspected of being malignant. This revealed 10 carcinomas, 1 borderline lesion and 11 adenomas. All patients underwent surgery, and the histological diagnosis was confirmed by examination of resected specimens. CE-US was performed using a contrast agent. The detection rates of mural nodules were compared between CE-US and contrast-enhanced computed tomography (CE-CT), and the imaging of mural nodules depicted under CE-US was analyzed. Results: Seventeen of 22 resected specimens (77.3%) had mural nodules. There was no significant difference in the detection rate between CE-US (n = 15; 88.2%) and CE-CT (n = 12; 70.6%). In 12 (80.0%) of these patients, CE-US revealed small vessels in the mural nodule. The spotty or linear-shaped pattern was detected in 4 patients and the branch-shaped pattern in 8. The branch-shaped pattern lesion was associated with carcinoma. These mural nodules were 10 mm or more in height. In the perfusion image phase, cystic walls and mural nodules were also enhanced in all cases. Conclusion: The vessel shapes of the mural nodules depicted under CE-US were associated with size and pathological findings. These results suggested that CE-US with a contrast agent is a powerful modality with which to evaluate the malignant potential of IPMN.

  12. Contrast-enhanced MR angiography in Leriche's syndrome

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Brossmann, J.; Heller, M.; Loose, R.

    1998-01-01

    Purpose: To determine the usefulness of contrast-enhanced MR angiography for the diagnosis of Leriche's syndrome. Material and methods: Leriche's syndrome was seen in 7 patients via DSA. In [dition, contrast-enhanced MR angiography was performed (T R 7.8 ms/T E 2.1 ms, flip angle 30 , slab thickness 116 mm, slice thickness 1.82 mm, 64 partitions, FOV 500x438 mm, matrix 224x512). Results: Diagnosis of Leriche's syndrome was possible by contrast-enhanced MR angiography in each case. Visualisation of the femoral arteries was not possible in two patients by intraarterial DSA, in three other patients there was an insufficient contrast in the femoral arteries with DSA. Contrast-enhanced MR angiography revealed good visualisation of the femoral arteries in these patients. In [dition, contrast-enhanced MR angiography allowed complete visualisation of the patent lower limb arteries. In intraarterial DSA visualisation of the lower limb arteries was achieved reached in only one patient, but was incomplete. Conclusion: Contrast-enhanced MR angiography yielded the correct diagnosis of Leriche's syndrome in all 7 patients. Contrast-enhanced MR angiography was superior to DSA in the assessment of the distal run-off vessels in five of seven patients. (orig.) [de

  13. Comparison of Dynamic Contrast-Enhanced MRI and PET/CT in the Evaluation of Laryngeal Cancer After Inadequate CT Results

    International Nuclear Information System (INIS)

    Citil, Serdal; Dogan, Serap; Atilgan, Hasan Ikbal; Menzilcioglu, Mehmet Sait; Sahin, Tuna; Abdulrezzak, Ummuhan; Duymus, Mahmut; Ozturk, Mustafa

    2015-01-01

    To investigate the diagnostic value of dynamic magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) for laryngeal cancers after inadequate CT results. The study comprised 45 patients investigated for primary laryngeal cancer or recurrence-residue in which CT was considered inadequate. A mass was found in 20 patients. Dynamic MRI and PET/CT were compared for diagnosis of mass, lymph node involvement, recurrence and residue. The dynamic curves formed in dynamic MRI were investigated for diagnostic contributions. The sensitivity and specificity of the dynamic MRI, for supraglottic, glottic and subglottic location, was 100%, 80%, and 92%; 100%, 85%, and 100%, respectively. In PET/CT the sensitivity and specificity were 100% for all of those localizations. For lymph node involvement, the sensitivity of dynamic MRI and PET/CT was 100%, the specificity was 100% and 93%, respectively. For recurrence-residue, the sensitivity and specificity of dynamic MRI were 86% and 67%, respectively, with 100% sensitivity and specificity in PET/CT. The sensitivity of type A curve for detection of malignancy was 40%, and specificity was 100%. When type A and B curves were included, the sensitivity was 100%. For patients investigated for laryngeal cancer in which CT is considered inadequate, dynamic MRI or PET/CT is useful

  14. Comparison of Dynamic Contrast-Enhanced MRI and PET/CT in the Evaluation of Laryngeal Cancer After Inadequate CT Results.

    Science.gov (United States)

    Citil, Serdal; Dogan, Serap; Atilgan, Hasan Ikbal; Menzilcioglu, Mehmet Sait; Sahin, Tuna; Abdulrezzak, Ummuhan; Duymus, Mahmut; Ozturk, Mustafa

    2015-01-01

    To investigate the diagnostic value of dynamic magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) for laryngeal cancers after inadequate CT results. The study comprised 45 patients investigated for primary laryngeal cancer or recurrence-residue in which CT was considered inadequate. A mass was found in 20 patients. Dynamic MRI and PET/CT were compared for diagnosis of mass, lymph node involvement, recurrence and residue. The dynamic curves formed in dynamic MRI were investigated for diagnostic contributions. The sensitivity and specificity of the dynamic MRI, for supraglottic, glottic and subglottic location, was 100%, 80%, and 92%; 100%, 85%, and 100%, respectively. In PET/CT the sensitivity and specificity were 100% for all of those localizations. For lymph node involvement, the sensitivity of dynamic MRI and PET/CT was 100%, the specificity was 100% and 93%, respectively. For recurrence-residue, the sensitivity and specificity of dynamic MRI were 86% and 67%, respectively, with 100% sensitivity and specificity in PET/CT. The sensitivity of type A curve for detection of malignancy was 40%, and specificity was 100%. When type A and B curves were included, the sensitivity was 100%. For patients investigated for laryngeal cancer in which CT is considered inadequate, dynamic MRI or PET/CT is useful.

  15. Selection of nonessential intravenous contrast enhanced-computed tomography for diagnosing acute appendicitis

    International Nuclear Information System (INIS)

    Kondo, Naoko; Kitagawa, Yoshimi; Satake, Tatsunari; Mayumi, Toshihiko; Kohno, Hiroshi

    2007-01-01

    Since computed tomography (CT) has made acute appendicitis increasingly easy to diagnose correctly, intravenous contrast-enhanced CT (IV-CT) is increasingly used for this diagnosis. The purpose of this study is to clarify an indication of IV-CT and to eliminate unnecessary IV-CT. We studied whether IV-CT is necessary in all patients suspected of acute appendicitis, given the interval between onset and clinical diagnosis. IV-CT was performed in patient who had right lower quadrant abdominal pain or who had no pain but physical findings at right lower quadrant abdomen. We reviewed detailed medical records of 171 consecutive patients who underwent IV-CT followed by appendectomy within 24 hr. We compared Blumberg's sign, muscle guarding, body temperature, white blood cell count, and C reaction protein, dividing patients into 3 groups-half a day, in which the interval between onset and initial diagnosis was shorter than half a day; 1-day, in which the interval was longer than half a day but shorter than 1 day; and multiple-day, in which the interval exceeded 1 day. We also analyzed IV-CT findings for the abnormal appendix and the number of positive individual CT findings including abnormal appendix, calcified appendicolith, ascites, cecal wall thickening, and dilated intestines. Muscle guarding was significantly common in the patients who had appendicitis among 1-day and multiple-day patients. In IV-CT, enlarged appendix was observed more frequently in those with appendicitis in all 3 groups. Positive individual CT findings were detected more often in multiple-day patients who had appendicitis. We found no significant difference among the other items. A patient diagnosed clinically later than half a day after onset and having muscle guarding should be strongly suspected having acute appendicitis, indicating that IV-CT is not needed in such patients. (author)

  16. NMR characteristics of low-grade glioma. Comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Asato, Reinin; Tokuriki, Yasuhiko; Nakano, Yoshihisa; Itoh, Harumi; Torizuka, Kanji; Ueda, Tohru; Yamashita, Junkoh; Handa, Hajime

    1985-08-01

    Sixteen low-grade gliomas were evaluated both with nuclear magnetic resonance (NMR) imaging and with computed tomography (CT). In 13 cases (81%), the NMR images were much better in tissue contrast than the contrast-enhanced CT images. The tumors were shown as well-circumscribed oval lesions in the NMR, though they appeared as ill-defined, irregular, low-attenuation areas in the CT. The extent of the lesion, which was supposed to represent the active tumor tissue, was greater in the NMR than in the CT, because NMR tissue parameters (T/sub 1/, T/sub 2/) are more sensitive to pathological changes in brain tissue than is the X-ray attenuation coefficient. Though, in an optic glioma and a brain-stem astrocytoma, the CT with contrast enhancement displayed the contour of the mass as well as did NMR, it was inferior to the NMR in showing the cephalocaudal extension of the tumors. Calcification does not give a proton NMR signal under the present measuring conditions; thus the calcified cystic wall of a hypothalamic astrocytoma was displayed only in the CT images. In conclusion, the NMR imaging was apparently superior to contrast-enhanced CT in demonstrating the lesions due to low-grade glioma.

  17. The validity and findings of superselective angio-CT of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tomura, Noriaki; Kusaka, Kazuya; Kato, Koki; Sato, Kimihiko; Watarai, Jiro; Sasajima, Hiroyasu; Kowada, Masayoshi [Akita Univ. (Japan). School of Medicine; Hatayama, Takashi

    1995-09-01

    Superselective angio-CT (SSA-CT) was performed on 12 patients with malignant astrocytomas who had been treated with superselective intra-arterial infusions of ACNU. SSA-CT was done at the time of super-selective intra-arterial infusion. Following conventional intra-arterial DSA for which a 6-F catheter was used, a microcatheter (Tracker-18) was passed coaxially inside the guiding catheter, and advanced into the feeding arteries of the tumor. After the microcatheter was placed in the proper position, a dynamic CT was performed with contrast administration into the feeding arteries. A GE CT/T 9800 scanner was used; the contrast medium was iopamidol which was administered diluted with 5 volumes of saline. There was representation of tumor stains by SSA-CT in all 12 patients, and of the medullary veins in three. In contrast, DSA or conventional enhanced CT represented tumor stain/enhancement in only 10 patients, and the medullary veins in one. In two patients who had no contrast tumor enhancement on the CT with contrast, SSA-CT could represent tumor stain. SSA-CT was also superior to DSA and conventional CT for the visualization of medullary veins The feeding artery in a patient with a posterior frontal astrocytoma was unclear on DSA. However, SSA-CT with contrast administration in the anterior cerebral artery revealed tumor stain; this modality was also useful for identifying the artery to be used for ACNU infusion. In another patient with a tumor in the parahippocampal gyrus, SSA-CT with contrast administration in the posterior cerebral artery could provide the proper position of the catheter for the infusion of ACNU. None of the patients experienced complications due to catheterization nor any systemic side-effects. (H.O.).

  18. Assessment of arterial hypervascularity of hepatocellular carcinoma: comparison of contrast-enhanced US and gadoxetate disodium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Sugimoto, Katsutoshi; Moriyasu, Fuminori; Taira, Junichi; Imai, Yasuharu; Shiraishi, Junji; Saito, Kazuhiro; Saguchi, Toru

    2012-01-01

    To compare contrast-enhanced (CE) ultrasound with gadoxetate disodium-enhanced magnetic resonance (MR) imaging in the assessment of arterial hypervascularity of hepatocellular carcinoma (HCC) and dysplastic nodule (DN), with CT during hepatic arteriography (CTHA) as the reference standard. This study included 54 consecutively diagnosed patients, with 57 histologically confirmed HCCs and 3 DNs (high-grade). All patients underwent CE ultrasound, gadoxetate disodium-enhanced MR imaging and CTHA. Two trained diagnostic radiologists interpreted the CTHA images and rated the degree of intratumoral arterial vascularity by consensus using a five-point confidence scale as the reference standard. In the observer study, the degrees of vascularity on CE ultrasound and gadoxetate disodium-enhanced MR images were qualitatively analysed by four independent readers using a five-point confidence scale. Diagnostic accuracy was analysed by receiver-operating characteristic (ROC) analysis. The diagnostic accuracies of the average area under the ROC curve (AUC) were significantly greater with CE ultrasound (average AUC: 0.94; 95% confidence interval [CI]: 0.88-1.00) than with gadoxetate disodium-enhanced MR imaging (average AUC 0.84, 95% CI 0.74-0.93, P = 0.0014). Contrast-enhanced ultrasound yields a significantly higher AUC value than gadoxetate disodium-enhanced MR imaging in the assessment of arterial hypervascularity of HCC and DN. Key Points circle Arterial hypervascularity is an important feature determining treatment options in hepatocellular carcinoma. circle It can be assessed by contrast-enhanced (CE) ultrasound or magnetic resonance (MR) imaging. circle CE ultrasound was more accurate than Gd-EOB-DTPA MRI in assessing intratumoral vascularity. circle Hypovascular hepatic nodules should be further investigated using CE ultrasound. (orig.)

  19. Carotid artery dissection on non-contrast CT: Does color improve the diagnostic confidence?

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca, E-mail: lucasaba@tiscali.it [Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari – Polo di Monserrato, s.s. 554 Monserrato, Cagliari 09045 (Italy); Argiolas, Giovanni Maria [Department of Radiology, Azienda Ospedaliero Brotzu (A.O.B.), di Cagliari, Cagliari 09100 (Italy); Raz, Eytan [Department of Radiology, New York University School of Medicine, New York (United States); Department of Neurology and Psychiatry, Sapienza University of Rome (Italy); Sannia, Stefano [Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari – Polo di Monserrato, s.s. 554 Monserrato, Cagliari 09045 (Italy); Suri, Jasjit S. [Diagnostic and Monitoring Division, AtheroPointTM LLC, Roseville, CA (United States); Electrical Engineering Department (Aff.), Idaho State University, ID (United States); Siotto, Paolo [Department of Radiology, Azienda Ospedaliero Brotzu (A.O.B.), di Cagliari, Cagliari 09100 (Italy); Sanfilippo, Roberto; Montisci, Roberto [Department of Vascular Surgery, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari – Polo di Monserrato, s.s. 554 Monserrato, Cagliari 09045 (Italy); Piga, Mario [Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari – Polo di Monserrato, s.s. 554 Monserrato, Cagliari 09045 (Italy); Wintermark, Max [Department of Radiology, Neuroradiology Division, University of Virginia, Box 800170, Charlottesville, VA, 22908 (United States)

    2014-12-15

    Highlights: • The use of a color scale to display the non-contrast CT images in lieu of the classic grayscale improves the diagnostic confidence of the readers. • Radiologists should consider the use of a color scale, rather than the conventional grayscale, to assess non-contrast CT studies for possible carotid artery dissection. - Abstract: Purpose: The purpose of this work was to evaluate if the use of color maps, instead of conventional grayscale images, would improve the observer's diagnostic confidence in the non-contrast CT evaluation of internal carotid artery dissection (ICAD). Materials and methods: One hundred patients (61 men, 39 women; mean age, 51 years; range, 25–78 years), 40 with and 60 without ICAD, underwent non-contrast CT and were included in this the retrospective study. In this study, three groups of patients were considered: patients with MR confirmation of ICAD, n = 40; patients with MR confirmation of ICAD absence, n = 20; patients who underwent CT of the carotid arteries because of atherosclerotic disease, n = 40. Four blinded observers with different levels of expertise (expert, intermediate A, intermediate B and trainee) analyzed the non-contrast CT datasets using a cross model (one case grayscale and the following case using the color scale). The presence of ICAD was scored on a 5-point scale in order to assess the observer's diagnostic confidence. After 3 months the four observers evaluated the same datasets by using the same cross-model for the alternate readings (one case color scale and the following case using the grayscale). Statistical analysis included receiver operating characteristics (ROC) curve analysis, the Cohen weighted test and sensitivity, specificity, PPV, NPV, accuracy, LR+ and LR−. Results: The ROC curve analysis showed that, for all observers, the use of color scale resulted in an improved diagnostic confidence with AUC values increasing from 0.896 to 0.936, 0.823 to 0.849, 0.84 to 0.909 and 0

  20. CT and MR imaging characteristics of infantile hepatic hemangioendothelioma

    International Nuclear Information System (INIS)

    Feng Shiting; Chan Tao; Ching, A.S.C.; Sun Canhui; Guo Huanyi; Fan Miao; Meng Quanfei; Li Ziping

    2010-01-01

    Aim: This study aims to analyze computed tomography (CT) and magnetic resonance (MR) imaging features of infantile hepatic hemangioendotheliomas before and after treatment. Materials and methods: CT and MR examinations of seven infants with biopsy proven hepatic hemangioendotheliomas were retrospectively analyzed. The distribution, number, size, imaging appearance, enhancement pattern and post-treatment changes of the tumors were evaluated. Results: A total of 153 hepatic hemangioendotheliomas were detected on CT (111) and MR (42) imaging. In six infants, 109/111 (98.2%) tumors were hypodense and 2/111 (1.8%) lesions contained calcification on unenhanced CT. On MR imaging, all 42 lesions in one infant were heterogeneously T1-hypointense and T2-hyperintense compared to the normal liver parenchyma. Contrast-enhanced CT and MRI showed peripheral rim (51.6%), uniform (48.4%), fibrillary (33.3%), and nodular (28.8%) contrast enhancement in the hepatic arterial phase. Homogeneous (100%), rim (98.2%) and mixed enhancement patterns were noted in tumors 2.0 cm and 1.0-2.0 cm in diameter respectively in the hepatic arterial phase. In three patients who underwent steroid therapy, follow-up CT examination demonstrated tumor size reduction and increased intra-tumoral calcification in two patients. Conclusion: Infantile hepatic hemangioendotheliomas show some typical imaging features and size-dependent pattern of contrast enhancement on CT and MR imaging, which allow accurate imaging diagnosis and post-treatment evaluation.