WorldWideScience

Sample records for contrast barium enema

  1. A new double contrast barium enema

    International Nuclear Information System (INIS)

    Park, Jun Sang; Cho, Won Sik; Lee, Sung Woo; Lee, Mun Gyu; Jeon, Jeong Dong; Jaun, Woo Ki; Han, Chung Yul

    1987-01-01

    A new technic of the barium enema was proposed for the better colonic double contrast study with the average 204ml of 50w/v% barium, applied to 109 serial patients. The barium was introduced to sigmoid colon, and then pushed to a mid transverse colon by the air insufflation through an enema syringe, a new device. An advance to cecum is accomplished by the air insufflation and/or the position change of the patient. The barium transfer method was developed for the best spot film exposure, through colon, by the position change of the patient, the tilting of the x-ray table and the air insufflation with the enema syringe. The mean angle of the x-ray table tilted was -10 .deg. at the beginning the barium enema till the barium sent past the splenic flexure, -15 . deg. for the best lateral view of rectum and -18 .deg. for the bet prone PA view of rectosigmoid colon. This was a simple, better and economic double contrast barium enema for the cooperative patients

  2. Barium enema (image)

    Science.gov (United States)

    A barium enema is performed to examine the walls of the colon. During the procedure, a well lubricated enema tube is inserted gently into the rectum. The barium, a radiopaque (shows up on X-ray) contrast ...

  3. Complications from radiographer-performed double contrast barium enemas

    Energy Technology Data Exchange (ETDEWEB)

    Vora, P.; Chapman, A. E-mail: anthony.chapman@leedsth.nhs.uk

    2004-04-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted.

  4. Complications from radiographer-performed double contrast barium enemas

    International Nuclear Information System (INIS)

    Vora, P.; Chapman, A.

    2004-01-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted

  5. Prospective comparison of air-contrast barium enema and colonoscopy in patients with fecal occult blood: a pilot study.

    Science.gov (United States)

    Rockey, Don C; Koch, Johannes; Yee, Judy; McQuaid, Kenneth R; Halvorsen, Robert A

    2004-12-01

    The utility of air-contrast barium enema and colonoscopy for evaluation of the colon has been debated. Air-contrast barium enema is less expensive and invasive than colonoscopy, but it also is less sensitive and specific. Further, although air-contrast barium enema may be less painful than colonoscopy, it often is poorly tolerated by patients. Thus, this study compared the sensitivity and the specificity of air-contrast barium enema and colonoscopy for detection of colonic lesions in patients with fecal occult blood. Over a 30-month period, patients with fecal occult blood were recruited. Patients underwent standard air-contrast barium enema, followed by colonoscopy 7 to 14 days later. Colonoscopists were blinded to the results of air-contrast barium enema until the colonoscopy was completed, after which the results were disclosed. If the findings were discrepant, colonoscopy was repeated. A total of 100 patients were evaluated. Nine air-contrast barium enemas were reported to be inadequate, and the cecum was not intubated at colonoscopy in two patients. In the remaining patients, 5 cancers were identified (1 each cecum, transverse colon, descending colon, sigmoid colon, and rectum) by both studies. Sixty-six polypoid lesions were identified in 30 patients. Diverticula were identified in 42 patients by air-contrast barium enema and in 18 patients by colonoscopy. Air-contrast barium enema detected 3 of 36 polypoid lesions 5 mm or less in diameter, 5 of 15 adenomas 6 to 9 mm in size, and 4 of 15 adenomas 10 mm or greater in diameter (sensitivity 8%, 33%, and 27%, respectively). After excluding patients with diverticula, air-contrast barium enema detected 3 of 7 adenomas 10 mm or greater in size. Overall, 12 polypoid lesions or filling defects were identified by air-contrast barium enema that could not be verified by colonoscopy. The specificity of air-contrast barium enema for lesions 1.0 cm or greater in size was 100%; for those 6 mm or greater, it was 97%. Air-contrast

  6. Granulomatous colitis: findings on double contrast barium enema and follow-up studies

    International Nuclear Information System (INIS)

    Song, Jong Gi; Han, Joon Koo; Kim, Seung Hoon; Choo, Sung Wook; Kim, Seung Cheol; Choi, Byung Ihn

    1995-01-01

    To evaluate the radiologic findings of granulomatous colitis on double contrast barium enema and changes on follow-up studies. Serial double contrast barium enema of six patients with granulomatous colitis confirmed by endoscopic biopsy were reviewed. We analyzed the radiologic findings and their follow-up changes, including aphthous ulcers, lymphoid hyperplasia, deep ulcers, cobble stone appearance, geographic ulcers, asymmetric involvement of ulcers, skip lesions, sinus tract, fistula formation, pseudosacculation, focal stricture, and small bowel involvement. Pretreatment double contrast barium enema findings were aphthous ulcers in five patients, deep ulcer in six, cobble stone appearance in five, longitudinal geographic ulcers in two, fistulas in one, pseudosacculations in two, focal stricture in one, and pseudopolyps in six. Also, anal ulcers were observed in two patients, asymmetric involvement of ulcers in three, skip lesions in four, and small bowel involvement in five in five patients proved to have inactive disease after treatment, aphthous ulcers and deep ulcers disappeared. Geographic ulcers of two patients and anal ulcer of one patients decreased in size or depth. Pseudosacculation in one patient disappeared. Pseudopolyps decreased in two patients, increased in one, and decreased after increase in two. One patient whose disease remained active after treatment showed maintenance or increase of ulcers or fistula. And their pseudosacculation or focal stricture unchanged and pseudopolyps decreased. The major radiologic findings of chronic granulomatous colitis on double contrast barium enema are aphthous ulcer, deep ulcer, cobble stone appearance, discontinuity of the lesion and coexistence of ulcers and pseudopolyps. And, double contrast barium enema is good follow-up modality because its findings correlate with clinical course of the granulomatous colitis after treatment

  7. Sensitivity of single and double contrast barium enema in the detection of colorectal carcinoma

    International Nuclear Information System (INIS)

    Myllylae, V.; Paeivansalo, M.; Laitinen, S.; Oulu Univ.

    1984-01-01

    The preoperative barium enema of the 188 colorectal carcinoma patients operated at the Oulu University Central Hospital (Finland) during 1977-1982 were examined retrospectively. Altogether 112 single contrast studies and 87 double contrast studies had been made on these patients. The single contrast barium enemas had resulted in a correct diagnosis of colorectal carcinoma in 93 cases (sensitivity 83%). The correct diagnosis in the double contrast studies numbered 71 (sensitivity 82%). Most of the overlooked carcinomas were located in the caecum, in the sigmoid or the rectum. Most of the errors made in the single contrast studies were due to detection errors and poor evacuation. The most common failures in double contrast enemas were detection errors and nonvisualisation of the sigmoid. The authors recommend use of the double contrast technique and suggest that the two methods of barium enema be used to complement each other. A false negative diagnosis delayed the operation of the colorectal carcinoma patients by 2.2 months (median). (orig.) [de

  8. Prospective comparison of double contrast barium enema plus flexible sigmoidoscopy v colonoscopy in rectal bleeding: barium enema v colonoscopy in rectal bleeding.

    OpenAIRE

    Irvine, E J; O'Connor, J; Frost, R A; Shorvon, P; Somers, S; Stevenson, G W; Hunt, R H

    1988-01-01

    Rectal bleeding often heralds serious colonic disease. The literature suggests that colonoscopy is superior to barium enema plus sigmoidoscopy, although no good comparative studies exist. Seventy one patients with overt rectal bleeding had prospectively flexible sigmoidoscopy, double contrast barium enema and colonoscopy completed independently. Against the gold standard, the sensitivity and specificity of colonoscopy were 0.69 and 0.78 respectively for a spectrum of colonic lesions, while fo...

  9. Early colon cancer : findings on double contrast barium enema

    International Nuclear Information System (INIS)

    Kim, Seung Kwon; Lim, Jae Hoon; Lee, Soon Jin; Lim, Hyo Keun

    1998-01-01

    The purpose of this study is to describe the radiologic findings of early colon cancer on double-contrast barium enema. We retrospectively reviewed the double-contrast barium enemas of eight patients (M:F = 6:2; mean age : 67 yrs; range : 48-77 yrs) who were pathologically proven to be early colon cancer. The location, size and gross morphology of lesions was evaluated using double-contrast barium enema, while depth of invasion, degree of differentiation, precancerous lesions and lymph node metastasis were evaluated histopathologically. Early colon cancer was found in the rectum (n=4), sigmoid colon (n=3) and ascending colon (n=1). The size of mass ranged from 2.3 ∼ 8.3 (mean, 4.6) cm. And the polypoid type was most common (n=7); this was subdivided into sessile (Is, n=5), semipedunculated (Isp, n=1) and pedunculated type (Ip, n=1). Another mass was a sessile polypoid combined with a flat depressed lesion. In eight cases, four cancers were confined to the mucosa, while the remaining four had infiltrated the submucosa. Most cancers arose from villous and villotubular adenoma. All cases were well-differentiated adenocarcinoma and no metastasis to lymph nodes had occurred. In early colon cancer, lesions were mainly polypoid and large. Most arose from villous and villotubular adenoma. (author). 19 refs., 1 tab., 3 figs

  10. Sensitivity of single contrast barium enema with regard to colorectal disease as diagnosed by colonoscopy

    International Nuclear Information System (INIS)

    Kaude, J.V.; Harty, R.F.

    1982-01-01

    The results of single contrast barium enema were retrospectively correlated with colonoscopically diagnosed colorectal disease in 54 patients (75 lesions). Altogether 66 lesions (88%) were correctly diagnosed. The sensitivity of barium enema for polyps was 81% (26/32). There were three perceptive errors and three polyps 5 mm or less in size were not demonstrated by barium enema. Twenty-nine cases of inflammatory disorders were all correctly diagnosed. One of 12 malignancies was missed by perceptive error. In two cases with vascular malformations the barium enema was normal. 4/9 (44%) of missed lesions were perceptive errors and could have been probably avoided by a second independent reading of films. (orig.)

  11. Barium enema

    Science.gov (United States)

    ... series; Colorectal cancer - lower GI series; Colorectal cancer - barium enema; Crohn disease - lower GI series; Crohn disease - barium enema; Intestinal blockage - lower GI series; Intestinal blockage - ...

  12. Routine filtration for decubitus radiography during double contrast barium enema examinations

    International Nuclear Information System (INIS)

    Camellini, V.; Abelli, P.; Marconi, G.

    1987-01-01

    A wedge-shaped plexiglass compensation filter for use in lateral decubitus radiographs of double contrast barium enema examinations has been designed. This filter, which has been used since February 1985, was compared with a second plexiglass filter, made by E-Z-EM. Voltage and amperage were kept contrast. Two different experiments were conducted in order to demonstrate the benefits of routine use of this compensation filter. First, the changes in skin dose were assessed using an ionization chamber on phantom. Secondly, three radiologists examined a series of 80 consecutive barium enemas without knowing which had been performed using the new filter. Out of the 70 examinations they considered excellent, as many as 45 had been performed with the new filter. Personal experience and the studies described show that the use of a compensation filter improves the accuracy and thus the diagnostic quality of the examinations as it enhances the detail of the anatomic structure of the colon; moreover the filter reduces skin exposure by up to 73.1% (EZ-E-EM filter 47.3%) and, at the same time, less radiographic films are needed. Routine use of a plexiglass compensation filter in lateral decubitus radiographs while performing a double contrast barium enema examination, is strongly recommended especially in obese patients

  13. Imaging assessment of the modified double contrast barium enema using carboxymethylcellulose on radiography and ultrasonography in dogs.

    Science.gov (United States)

    Choi, Mihyun; Lee, Namsoon; Kim, Junyoung; Yi, Kangjae; Jung, Joohyun; Yoon, Junghee; Choi, Mincheol

    2011-01-01

    A modified double contrast barium enema using carboxymethylcellulose was evaluated in beagle dogs and compared with dogs receiving a conventional barium enema. The experimental group was divided into three groups (1, 2, and 3) and given 30 ml/kg of different volume ratios of a barium vs. carboxymethylcellulose mixture. Each group underwent sonography following radiography. The volume ratio of one part barium to three parts carboxymethylcellulose was judged to be the optimal mixture, resulting in a general distribution of contrast and bowel radiolucency on radiographs and adequate postradiography sonography. The modified barium enema using carboxymethylcellulose is useful for assessing the general morphology and mucosal layers of the colon simultaneously on radiographs and ultrasonographs.

  14. Detection of colonic polyps in the elderly: Optimization of the single-contrast barium enema examination

    International Nuclear Information System (INIS)

    Gelfand, D.W.; Chen, Y.M.; Ott, D.J.; Munitz, H.A.

    1986-01-01

    Single-contrast studies account for 75% of barium enema examinations and are often performed in the elderly. By optimizing all factors, the following results were obtained: for polyps of less than 1 cm, 40 of 57 were detected (sensitivity, 70.2%); for polyps of 1 cm or larger, 33 of 35 were detected (sensitivity, 94%). Overall, 73 of 92 polyps were detected (sensitivity, 79.3%). These sensitivities result from meticulous preparation and the use of compression filming, low-density barium, moderate kilovoltages, high-resolution screens, remote control apparatus, and high-bandpass TV fluoroscopy. The authors conclude that an optimal single-contrast barium enema examination detects colonic polyps with a sensitivity approaching that of the double-contrast study and may be employed in elderly patients who cannot undergo the double-contrast study

  15. Barium sulfate aspiration: Severe chemical pneumonia induced by a massive reflux of contrast medium during small bowel barium enema.

    Science.gov (United States)

    Zhang, Lin; Yang, Yi; Zhang, Ji; Zhou, Xiaowei; Dong, Hongmei; Zhou, Yiwu

    2015-08-01

    Barium contrast radiography is a conventional procedure aimed at revealing lesions of the alimentary tract using barium sulfate on X-ray irradiation. Although it is widely used in clinics, adverse effects and complications are observed, such as anaphylaxis, granuloma, fecalithes, abdomen-leaking, embolism, bacterial contamination, and aspiration. We report a case of death due to a massive barium sulfate aspiration resulted from an air-barium double contrast enema radiography. A 25-year-old female patient was hospitalized with symptoms of abdominal distention, nausea, vomiting and diarrhea for three days. A progressive respiratory distress presented only 1h after a small bowel air-barium double contrast enema. The patient died 11h later. The result of autopsy revealed the cause of death to be severe chemical pneumonitis induced by gastric fluid which was aspirated into her lungs. Barium sulfate is generally recognized to be chemically inert for the respiratory system, but a mixture of barium sulfate with gastric contents is fatal. Here we intend to suggest that, when determining the potential cause of death, medical examiners should consider a patient's status quo as well as the possible adverse effects and complications caused by the barium sulfate preparation during gastrointestinal radiography. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Radiographer and radiologist perception error in reporting double contrast barium enemas: A pilot study

    International Nuclear Information System (INIS)

    Booth, Alison M.; Mannion, Richard A.J.

    2005-01-01

    Purpose: The practice of radiographers performing double contrast barium enemas (DCBE) is now widespread and in many centres the radiographer's opinion is, at least, contributing to a dual reporting system [Bewell J, Chapman AH. Radiographer performed barium enemas - results of a survey to assess progress. Radiography 1996;2:199-205; Leslie A, Virjee JP. Detection of colorectal carcinoma on double contrast barium enema when double reporting is routinely performed: an audit of current practice. Clin Radiol 2001;57:184-7; Culpan DG, Mitchell AJ, Hughes S, Nutman M, Chapman AH. Double contrast barium enema sensitivity: a comparison of studies by radiographers and radiologists. Clin Radiol 2002;57:604-7]. To ensure this change in practice does not lead to an increase in reporting errors, this study aimed to compare the perception abilities of radiographers with those of radiologists. Methods: Three gastro-intestinal (GI) radiographers and three consultant radiologists independently reported on a selection of 50 DCBE examinations, including the level of certainty in their comments for each examination. A blinded comparison of the results with an independent 'standard report' was recorded. Results: The results demonstrate there was no significant difference in perception error for any of the levels of certainty, for single reporting, for double reading by a radiographer/radiologist or by two radiologists. Conclusions: The study shows that radiographers can perceive abnormalities on DCBE at similar sensitivities and specificities as radiologists. While the participants in the study may be typical of a district general hospital, the nature of the study gives it limited external validity. As a pilot, the results demonstrate that, with slight modification, the methodology could be used for a larger study

  17. Compensation filtration for decubitus radiography during double-contrast barium enema examinations

    International Nuclear Information System (INIS)

    Feczko, P.J.; Haggar, A.M.; Rauch, P.L.; Halpert, R.D.; Simms, S.M.

    1983-01-01

    Lateral decubitus images obtained during double-contrast barium enema examinations may be difficult to interpret because of the large difference in density between the various parts of the radiographs. Several types of filters are described which can be used to rectify this problem, thus improving the quality of the decubitus radiographs and achieving a slight reduction in radiation exposure

  18. Outcome of barium enema in patients with colorectal symptoms ...

    African Journals Online (AJOL)

    Background: For many years, double contrast barium enema has been an effective way to evaluate the large bowel. With the development of the colonoscope, the role of barium enema has been questioned. However it is still useful in investigating patients with colorectal symptoms especially in the developing world where ...

  19. Colorectal cancer: screening double-contrast barium enema examination in average-risk adults older than 50 years.

    Science.gov (United States)

    Kung, Justin W; Levine, Marc S; Glick, Seth N; Lakhani, Paras; Rubesin, Stephen E; Laufer, Igor

    2006-09-01

    To retrospectively determine the diagnostic yield of double-contrast barium enema examinations performed for colorectal cancer screening of neoplasms 1 cm or larger or advanced neoplastic lesions of any size in average-risk adults older than 50 years. The Institutional Review Board at the affiliated Veterans Affairs Medical Center approved this HIPAA-compliant study protocol and did not require informed consent from patients. Computerized databases revealed 276 double-contrast barium enema examinations performed for colorectal cancer screening in average-risk adults older than 50 years. Radiographic and pathologic reports were reviewed to determine the number of patients who had polypoid lesions 1 cm or larger, polyps smaller than 1 cm, or advanced neoplastic lesions of any size. Forty-five (16.3%) of the 276 patients underwent follow-up sigmoidoscopy or colonoscopy. Medical, endoscopic, and pathologic records were reviewed and compared with radiographic findings. The results of double-contrast barium enema examination revealed 74 (26.8%) of 276 patients with 104 polypoid lesions in the colon, including 32 patients (11.6%) with 41 polypoid lesions 1 cm or larger, 15 patients (5.4%) with 19 polyps 6-9 mm, and 27 patients (9.8%) with 44 polyps 5 mm or smaller. Endoscopy was performed in 24 (75%) of 32 patients, the results of which confirmed 23 (72%) of 32 radiographically diagnosed lesions 1 cm or larger in 16 (67%) of 24 patients. In two of these individuals, the polyps were hyperplastic. The remaining 14 patients had a total of 21 neoplastic lesions 1 cm or larger, including 11 tubular adenomas, seven tubulovillous adenomas, one villous adenoma with marked dysplasia, and two cancers. The diagnostic yield of screening double-contrast barium enema examination was 5.1% (14 of 276 patients) for neoplastic lesions 1 cm or larger and 6.2% (17 of 276 patients) for advanced neoplastic lesions of any size. Double-contrast barium enema examinations performed in average

  20. Diagnostic role of barium enema in carcinoma rectum

    International Nuclear Information System (INIS)

    Asghar, M.

    2003-01-01

    Objective: The main aim of this barium enema study was to evaluate its role in patients suspected to have rectal pathologies with complaints of change in bowel habit, anorexia/weight loss, bleeding per rectum and acute/sub-acute colonic obstruction. Results: barium enema study as screening test for colo-rectal carcinoma was undertaken. Contrast outlined the colonic growth in 35 cases, out of which the cases of carcinoma colon were 24 including 13 patients suffering from carcinoma rectum. The percentage of carcinoma colon to total colonic growth was 68% while, carcinoma rectum to total carcinoma colon was 54%. Conclusion: On the basis of these investigations, it is concluded that patient's compliance is important factor in the early detection of colonic neoplasia. Though results of colonoscopy are more reliable but in practice, barium enema (double contrast) is performed initially to outline the lesion and then colonoscopy for biopsy purpose. (author)

  1. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Burling, D.; Bassett, P.; Bartram, C.I.

    2005-01-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients

  2. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.A. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)]. E-mail: csytaylor@yahoo.co.uk; Halligan, S. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Burling, D. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bassett, P. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bartram, C.I. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)

    2005-02-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients.

  3. Rectal water contrast transvaginal ultrasound versus double-contrast barium enema in the diagnosis of bowel endometriosis

    OpenAIRE

    Jiang, Jipeng; Liu, Ying; Wang, Kun; Wu, Xixiang; Tang, Ying

    2017-01-01

    Objectives The aim of study was to compare the accuracy between rectal water contrast transvaginal ultrasound (RWC-TVS) and double-contrast barium enema (DCBE) in evaluating the bowel endometriosis presence as well as its extent. Design and setting 198 patients at reproductive age with suspicious bowel endometriosis were included. Physicians in two groups specialised at endometriosis performed RWC-TVS as well as DCBE before laparoscopy and both groups were blinded to other groups’ results. Fi...

  4. Perforations during contrast enema

    International Nuclear Information System (INIS)

    Vogel, H.; Steinkamp, U.; Grabbe, E.; Allgemeines Krankenhaus Ochsenzoll, Hamburg

    1983-01-01

    During contrast enema, perforation into the retroperitoneal space can be differentiated from perforation into the peritoneum and perforation into the intestinal wall associated with formation of barium granulomas or submucosal spreading of the contrast medium. Other special forms are perforation with contrast medium embolism of diverticula; of the processus vermiformis; penetration of contrast medium into fistulous systems and from the operated areas. Risk factors are: balloon catheter, intestinal tubes with a hard tip, preternatural anus, excessive enema pressure, contrast medium additions, preceding manipulations, intestinal diseases, advanced age and delegation of manipulations to assistants and unskilled staff. Children are particularly at risk. (orig.) [de

  5. Cost-effectiveness of barium enemas performed by radiographers

    International Nuclear Information System (INIS)

    Brown, Lorraine; Desai, Sharad

    2002-01-01

    AIM: To assess the cost-effectiveness of barium enemas performed by radiographers compared to those performed by consultant radiologists. METHOD: Prospective study of 200 barium enemas carried out by a senior radiographer and a consultant radiologist. The sample was a consecutive sample of adult out-patients over a 3-month period, with no exclusion. The length of time of the enema and the numbers and grades of staff involved in the procedure were recorded. This was translated into staffing costs using the appropriate pay scales. RESULTS: The barium enemas performed by the superintendent radiographer were more cost-effective than those performed by the consultant radiologist (1406 pounds for 100 radiographer-performed barium enemas compared to 1787 pounds for 100 carried out by the consultant radiologist). CONCLUSION: In terms of staffing costs, radiographers performing barium enemas not only liberates radiologist time, it is also a cost-effective method of providing an out-patient barium enema service. Brown, L. and Desai, S. (2002)

  6. Effectiveness of therapeutic barium enema for diverticular hemorrhage.

    Science.gov (United States)

    Matsuura, Mizue; Inamori, Masahiko; Nakajima, Atsushi; Komiya, Yasuhiko; Inoh, Yumi; Kawasima, Keigo; Naitoh, Mai; Fujita, Yuji; Eduka, Akiko; Kanazawa, Noriyoshi; Uchiyama, Shiori; Tani, Rie; Kawana, Kennichi; Ohtani, Setsuya; Nagase, Hajime

    2015-05-14

    To evaluate the effectiveness of barium impaction therapy for patients with colonic diverticular bleeding. We reviewed the clinical charts of patients in whom therapeutic barium enema was performed for the control of diverticular bleeding between August 2010 and March 2012 at Yokohama Rosai Hospital. Twenty patients were included in the review, consisting of 14 men and 6 women. The median age of the patients was 73.5 years. The duration of the follow-up period ranged from 1 to 19 mo (median: 9.8 mo). Among the 20 patients were 11 patients who required the procedure for re-bleeding during hospitalization, 6 patients who required it for re-bleeding that developed after the patient left the hospital, and 3 patients who required the procedure for the prevention of re-bleeding. Barium (concentration: 150 w%/v%) was administered per the rectum, and the leading edge of the contrast medium was followed up to the cecum by fluoroscopy. After confirmation that the ascending colon and cecum were filled with barium, the enema tube was withdrawn, and the patient's position was changed every 20 min for 3 h. Twelve patients remained free of re-bleeding during the follow-up period (range: 1-19 mo) after the therapeutic barium enema, including 9 men and 3 women with a median age of 72.0 years. Re-bleeding occurred in 8 patients including 5 men and 3 women with a median age of 68.5 years: 4 developed early re-bleeding, defined as re-bleeding that occurs within one week after the procedure, and the remaining 4 developed late re-bleeding. The DFI (disease-free interval) decreased 0.4 for 12 mo. Only one patient developed a complication from therapeutic barium enema (colonic perforation). Therapeutic barium enema is effective for the control of diverticular hemorrhage in cases where the active bleeding site cannot be identified by colonoscopy.

  7. An oral modified-release nifedipine tablet (Adalat LA) and its appearance on double contrast barium enema

    International Nuclear Information System (INIS)

    Bleehen, Robert E.

    2000-01-01

    Adalat LA 30 mg and 60 mg tablets are widely prescribed oral modified release nifedipine preparations with a porous, non-digestible plastic tablet coating which is required in order to effect the osmotically driven slow release mechanism. These tablets may therefore be seen anywhere along the gastrointestinal tract and are passed apparently whole in the faeces. An example of the appearance within the rectum of Adalat LA 30 (Bayer) on double contrast barium enema is shown and the main features described. A review of the literature is given. Recognition of the appearances during the barium enema examination will prompt those performing the procedure to question the drug history where relevant and will reduce the incidence of false-positive reporting. Bleehen, R.E. (2000)

  8. Effectiveness of therapeutic barium enema for diverticular hemorrhage

    Science.gov (United States)

    Matsuura, Mizue; Inamori, Masahiko; Nakajima, Atsushi; Komiya, Yasuhiko; Inoh, Yumi; Kawasima, Keigo; Naitoh, Mai; Fujita, Yuji; Eduka, Akiko; Kanazawa, Noriyoshi; Uchiyama, Shiori; Tani, Rie; Kawana, Kennichi; Ohtani, Setsuya; Nagase, Hajime

    2015-01-01

    AIM: To evaluate the effectiveness of barium impaction therapy for patients with colonic diverticular bleeding. METHODS: We reviewed the clinical charts of patients in whom therapeutic barium enema was performed for the control of diverticular bleeding between August 2010 and March 2012 at Yokohama Rosai Hospital. Twenty patients were included in the review, consisting of 14 men and 6 women. The median age of the patients was 73.5 years. The duration of the follow-up period ranged from 1 to 19 mo (median: 9.8 mo). Among the 20 patients were 11 patients who required the procedure for re-bleeding during hospitalization, 6 patients who required it for re-bleeding that developed after the patient left the hospital, and 3 patients who required the procedure for the prevention of re-bleeding. Barium (concentration: 150 w%/v%) was administered per the rectum, and the leading edge of the contrast medium was followed up to the cecum by fluoroscopy. After confirmation that the ascending colon and cecum were filled with barium, the enema tube was withdrawn, and the patient’s position was changed every 20 min for 3 h. RESULTS: Twelve patients remained free of re-bleeding during the follow-up period (range: 1-19 mo) after the therapeutic barium enema, including 9 men and 3 women with a median age of 72.0 years. Re-bleeding occurred in 8 patients including 5 men and 3 women with a median age of 68.5 years: 4 developed early re-bleeding, defined as re-bleeding that occurs within one week after the procedure, and the remaining 4 developed late re-bleeding. The DFI (disease-free interval) decreased 0.4 for 12 mo. Only one patient developed a complication from therapeutic barium enema (colonic perforation). CONCLUSION: Therapeutic barium enema is effective for the control of diverticular hemorrhage in cases where the active bleeding site cannot be identified by colonoscopy. PMID:25987779

  9. Blood pressure changes during barium enema

    International Nuclear Information System (INIS)

    Roach, S.C.; Martin, O.J.D.; Owen, A.; Martin, D.F.

    2001-01-01

    AIMS: To document blood pressure changes during barium enema examination and to determine at what point in the examination changes are likely to occur. METHODS AND RESULTS: Blood pressure measurements were taken at seven points during the course of barium enema examination in 107 consecutive patients. We found that patients over the age of 60 years had statistically significant decreases in blood pressure when they were stood up during the course of the examination. Many of these patients were asymptomatic. Patients who had symptoms (15/107, 14%) when standing up had a degree of hypotension. The duration of barium enema examination is longer in those patients who experience symptoms. CONCLUSION: During a barium enema examination hypotension occurs at the point of standing up more frequently in patients over 60 years and in those who suffer symptoms at this time. Patients who fall into one of these groups should be considered at risk of fainting at this point in the examination. A modified technique to avoid standing should be considered in at-risk patients. Roach, S.C. et al. (2001)

  10. Barium enema findings of milk allergy in infants

    International Nuclear Information System (INIS)

    Kim, Gyoung Ju; Kim, Mi Jeong; Lee, Hee Jung

    2006-01-01

    We wanted to evaluate the barium enema findings of milk allergy in infants. Retrospective evaluation of the plain abdominal radiography and barium enema findings was performed in fifteen young infants suffering with milk allergy. The presence of gaseous distension, rectal gas, paralytic ileus and mechanical obstruction was evaluated on the plain radiography. The presence of spasm, a transitional zone, a reversed rectosigmoid index and mucosal irregularity was analyzed on the barium enema; the presence of barium retention was also evaluated on 24-hour-delayed plain radiography. Paralytic ileus was the most common finding on the plain radiography (93%). On the barium enema, continuous spasm of the colon, ranging from the rectum to the descending colon, was revealed in ten infants (67%). A transitional zone was observed in one infant and a reversed rectosigmoid index was revealed in four. Mucosal irregularity was observed in two infants. Barium retention was demonstrated in 11 of fifteen cases: throughout the entire colon (n = 3), from the rectum to the descending colon (n = 7), and up to the transverse colon (n = 1). The most common barium enema finding of milk allergy in infants was spasm of the distal colon. The other findings were a transitional zone, a reversed rectosigmoid index, mucosal irregularity and barium retention

  11. Patient dose variation investigated in four Irish hospitals for barium meal and barium enema examinations

    International Nuclear Information System (INIS)

    Carroll, E.; Brennan, P.C.

    2001-01-01

    Four hospitals have been studied, intra- and inter-hospital variations examined and the mean DAP values recorded for barium enemas and barium meals. Mean DAP values for barium meals and barium enemas at 11.4 Gy.cm 2 and 20.1 Gy.cm 2 respectively have been shown. Differences between individual examinations for barium meals varied by up to a factor of 185 and for barium enemas, up to a factor of 19, with hospital means for barium meal and enema examinations each differing by up to a factor of 3. The data provided by this study have suggested that large variations in patient dose do exist in Ireland for barium meal and barium enema examinations. Fluoroscopy time was shown to be a major contributor to the variations reported, with number of images playing a minor role. Results have demonstrated the need for standardisation of technique throughout the country for these examinations. (author)

  12. Early manifestation of Yersinia colitis demonstrated by the double-contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Aspestrand, F.

    1986-11-01

    A 19-year old female with a bloody, diarrheal illness of acute onset where Crohn's disease primarly was suspected is presented. The double-contrast barium enema revealed multiple, diffusely scattered aphthous erosions of the colonic mucosa: the rectum was scarcely affected. Biopsies taken by endoscopy demonstrated nonspecific inflammatory changes of the mucous membrane. However, routinely taken stool cultures revealed an infectious colitis due to Yersinia enterocolitica. Our case demonstrates the necessity to consider Yersinia enterocolitis in the radiographic differential diagnosis when the diagnosis of Crohn's disease or ulcerative colitis seems obvious.

  13. Correlation of double-contrast high-density barium enema, colonoscopy, and histology in children with special attention to disparities

    International Nuclear Information System (INIS)

    Stringer, D.A.; Sherman, P.M.; Jakowenko, N.

    1986-01-01

    Colonscopic and double-contrast high-density barium enema (DCBE) findings were correlated in 68 patients (39 boys and 29 girls) aged 6 months to 18 years (mean 11.6 years) evaluated over a 24-month period. There was excellent correlation in 53 patients (78.0%) and good correlation in another 3 (4.4%) who had identical diagnoses and only slightly differing extent of disease reported. In 2 of these, DCBE showed more extensive disease, confirmed histologically in 1. Distal colitis seen on colonoscopy as reddening and neovascularity was missed on DCBE in 6 patients. Colonoscopy and DEBE failed to show a polyp in 1 patient each. One patient who had a normal DCBE and colonoscopy demonstrated a histological abnormality, and 1 patient with an abnormality on histology and DCBE was normal on colonscopy. A disparity resulted from the time between procedures in 1 patient and observer error in another. This high correlation is far better than any previously reported in children, supporting the use of high-density barium sulfate and double-contrast barium enemas in pediatric patients. (orig.)

  14. Enterogastroesophageal reflux during barium enema: Report of a case

    International Nuclear Information System (INIS)

    Shin, Hyoun Ja; Rhee, Hak Song

    1972-01-01

    Enterogastric reflux during barium enema examination has been ascribed to various causes including incompetence of the ilepcecal valve, shunt, fistula, excessive barium etc. Recently we have encountered a case of complete enterogastroesphageal regurgitation during barium enema examination performed for the reduction of the ileocolic intuosusception in 6 months old baby. The regurgitation occurred only in the first of two barium enema examinations conducted at one month interval for recurring intussusception. The barium-saline solution used in the present study was not more than 350 ml in quantity. No organic or physical causes of such a complete regurgitation could be determined

  15. 21 CFR 201.304 - Tannic acid and barium enema preparations.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Tannic acid and barium enema preparations. 201.304... Tannic acid and barium enema preparations. (a) It has become a widespread practice for tannic acid to be added to barium enemas to improve X-ray pictures. Tannic acid is capable of causing diminished liver...

  16. The early manifestation of Yersinia colitis demonstrated by the double-contrast barium enema

    International Nuclear Information System (INIS)

    Aspestrand, F.

    1986-01-01

    A 19-year old female with a bloody, diarrheal illness of acute onset where Crohn's disease primarly was suspected is presented. The double-contrast barium enema revealed multiple, diffusely scattered aphthous erosions of the colonic mucosa: the rectum was scarcely affected. Biopsies taken by endoscopy demonstrated nonspecific inflammatory changes of the mucous membrane. However, routinely taken stool cultures revealed an infectious colitis due to Yersinia enterocolitica. Our case demonstrates the necessity to consider Yersinia enterocolitis in the radiographic differential diagnosis when the diagnosis of Crohn's disease or ulcerative colitis seems obvious. (orig.) [de

  17. Benefits of Barium Enema in Patients with Incomplete Colonoscopy. Prospective Study of 45 Cases

    International Nuclear Information System (INIS)

    Gispert, S.; Mayolas, N.; Hidalgo, A.

    2003-01-01

    To evaluate the usefulness of barium enema in patients with incomplete colonoscopy. There was carried out a prospective 10-month study of 45 patients with incomplete colonoscopy (27 men and 18 women), who were later examined by means of barium enema (33 conventional, 12 double-contrast) in order to check for additional pathology in portions of the colon not visualized by colonoscopy. Barium enema diagnosed six possible additional lesions (13.3%) in portions of the colon not visualized by incomplete colonoscopy (four neoplasia and two non-neoplasia). Regarding the neoplasia two were true positives and two false positives. Both true positives were adenocarcinomas (one synchronous caecum, and another in splenic angle). The two false positives corresponded to fecal matter stuck to the intestinal wall. Regarding the non-neoplasia, multiple stenosis was detected in a patient with Crohn's disease and an enterocolic fistula was found in a patient with sigmoid colon neoplasia. The diagnostic yield of barium enema in the detection of additional pathology in colon portions not visualized by colonoscopy was of 9%. Barium enema following incomplete colonoscopy permits a complete colon evaluation in most cases, and it offers additional diagnostic information. (Author) 21 refs

  18. Double contrast barium enema combined with non-invasive imaging in peritoneal mesothelioma

    International Nuclear Information System (INIS)

    Cozzi, G.; Bellomi, M.; Frigerio, L.F.; Ostinelli, C.; Marchiano, A.; Petrillo, R.; Severini, A.; Milan Univ.

    1989-01-01

    Mesotheliomas are rare tumors arising from serosal linings of the major serous cavities. Five patients with peritoneal mesothelioma underwent a double contrast barium enema (DCBE) and ultrasonography (US) (2 patients), computed tomography (CT) (3 patients) and/or magnetic resonance imaging (MRI) (3 patients). The diagnosis was confirmed at laparotomy. The radiologic pattern at DCBE is unspecific and consists of compression and dislocation of bowel loops by extrinsic masses. Mesenteric retraction and segmental stenosis may be present. In one patient DCBE was normal. US, CT and MRI findings are also unspecific but when combined with information obtained from DCBE the site and abdominal extension of the disease are well defined. (orig.)

  19. Double contrast barium enema: technique, indications, results and limitations of a conventional imaging methodology in the MDCT virtual endoscopy era.

    Science.gov (United States)

    Rollandi, Gian Andrea; Biscaldi, Ennio; DeCicco, Enzo

    2007-03-01

    The double contrast barium enema of the colon continues to be a diffused conventional radiological technique and allows for the diagnosis of neoplastic and inflammatory pathology. After the '70s, a massive initiative is undertaken to simplify, perfect and encode the method of the double contrast barium enema: Altaras from Germany, Miller from USA and Cittadini from Italy are responsible for the perfection of this technique in the last 30 years. The tailored patient preparation, a perfect technique of execution and a precise radiological documentation are essentials steps to obtain a reliable examination. The main limit of double contrast enema is that it considers the pathology only from the mucosal surface. In neoplastic pathology evaluation the main limit is the "T" parameter staging, but more limited are the "N" and "M" parameters evaluation. Today the double contrast technique continues to be a refined, sensitive and specific diagnostic method, moreover, diagnostic results cannot compete with the new CT multislice techniques (CT-enteroclysis and virtual colonoscopy) which can examine both the lumen and the wall of the colon. The double contrast is a cheap and simple examination but in the next future is predictably a progressive substitution of conventional radiology from new multislice techniques, because the cross sectional imaging is more frequently able to detect causes of the symptoms whether resulting both from colonic or non colonic origin.

  20. Double contrast barium enema: Technique, indications, results and limitations of a conventional imaging methodology in the MDCT virtual endoscopy era

    International Nuclear Information System (INIS)

    Rollandi, Gian Andrea; Biscaldi, Ennio; DeCicco, Enzo

    2007-01-01

    The double contrast barium enema of the colon continues to be a diffused conventional radiological technique and allows for the diagnosis of neoplastic and inflammatory pathology. After the '70s, a massive initiative is undertaken to simplify, perfect and encode the method of the double contrast barium enema: Altaras from Germany, Miller from USA and Cittadini from Italy are responsible for the perfection of this technique in the last 30 years. The tailored patient preparation, a perfect technique of execution and a precise radiological documentation are essentials steps to obtain a reliable examination. The main limit of double contrast enema is that it considers the pathology only from the mucosal surface. In neoplastic pathology evaluation the main limit is the 'T' parameter staging, but more limited are the 'N' and 'M' parameters evaluation. Today the double contrast technique continues to be a refined, sensitive and specific diagnostic method, moreover, diagnostic results cannot compete with the new CT multislice techniques (CT-enteroclysis and virtual colonoscopy) which can examine both the lumen and the wall of the colon. The double contrast is a cheap and simple examination but in the next future is predictably a progressive substitution of conventional radiology from new multislice techniques, because the cross sectional imaging is more frequently able to detect causes of the symptoms whether resulting both from colonic or non colonic origin

  1. The diagnostic value of barium enema in acute appendicitis

    International Nuclear Information System (INIS)

    Kim, Yong Ga; Chung, Duck Soo; Kim, Ok Dong

    1986-01-01

    Acute appendicitis is the most common acute surgical condition of the abdomen. When the clinical presentation is atypical, barium enema has proven to be safe and useful in confirming the diagnosis and reducing the negative surgical exploration. However, the performance of barium enema in acute appendicitis has known contraindication primarily because of fear of leakage by perforation of the inflamed appendix. This study using barium enema as a diagnostic aid in acute appendicitis with atypical clinical presentation was performed to further support the previously noted efficacy and safety of this procedure. The results were as followings: 1. In case of acute appendicitis with atypical clinical presentation, the use of barium enema as a diagnostic aid increased the accuracy of diagnosis and decreased the negative surgical exploration. In women between 11 to 50 years old age, especially, it played important role differentiating appendicitis from nonsurgical acute abdomen. 2. The results of the study were 92.31% in sensitivity, 7.69% in false positive, 6.9% in false negative, and 10.26% in negative appendectomy. 3. None of case of leakage of barium by perforation of the inflamed appendix was noted, therefore, barium enema was thought to be safe as a diagnostic aid in acute appendicitis. 4. A simple partial or non filling of appendix without other associated positive finding could not exclude appendicitis, therefore, close clinical observation was necessary. 5. The positive findings of barium enema and their sensitivity were as followings: 1. Non filling of appendix: 90% 2. Partial filling of appendix: 91.7% 3. Displacement or a local impression on terminal ileum: 100%

  2. Is a Double Contrast Barium Enema Necessary in Patients who Undergo a CT Colonography as a Preoperative Work-up?

    International Nuclear Information System (INIS)

    Lee, Ji Won; Lee, Soon Jin; Choi, Dong Il; Kim, Hee Jung; Chun, Ho Kyung; Yun, Seong Hyeon; Jeon, Yong Hwan; Park, Seung Bae; Kim, Min Ju

    2009-01-01

    To determine the efficiency of CT colonography (CTC), as compared with the double contrast barium enema (DCBE) for the preoperative work-up of colorectal neoplasms. A total of 39 patients underwent both a CTC and DCBE before surgery. Three abdominal radiologists and three colorectal surgeons retrospectively reviewed virtual double contrast (VDC) and DCBE images, regarding each examination for localization, conspicuity, extent and morphology of neoplasms. We reviewed the radiological reports of the CTC and DCBE for the polyps. In the case of both VDC and DCBE, 40 cancers were detected in 39 patients. According to abdominal radiologists, VDC showed the same ability to identify DCBE for localization of neoplasms (p 0.05). The performance of the CTC is comparable to the DCBE for the localization of main mass and polyps in patients with colorectal neoplasm. Barium enema don't seem to be necessary for patients who undergo a CTC as preoperative work-up

  3. Double contrast barium enema sensitivity: A comparison of studies by radiographers and radiologists

    International Nuclear Information System (INIS)

    Culpan, D.G.; Mitchell, A.J.; Hughes, S.; Nutman, M.; Chapman, A.H.

    2002-01-01

    PURPOSE: A retrospective study of histologically proven cases of colorectal cancer (CRC) was performed to assess whether the sensitivity of the radiographer-performed double contrast barium enema (DCBE) differed from that of the radiologist-performed study. MATERIALS AND METHODS: Histologically proven cases of CRC were reviewed over a 3-year period to ascertain whether: the diagnosis had been made by DCBE in the 3 years before histological diagnosis; the lesion had been correctly diagnosed; the examination had been performed by a radiologist or radiographer. RESULTS: In the 3-year period there were 478 cases with histologically proven CRC. Of these, 239 (50%) had undergone DCBE as the initial radiological investigation of the colon. Sixty-four examinations had been performed by radiographers. A correct diagnosis was made in 58 cases (90.6%), the report was equivocal in one case (1.6%), there were four false-negatives (6.25%), and one case was abandoned (1.6%). One hundred and seventy-five examinations were performed by radiologists. A correct diagnosis was made in 157 cases (89.7%), the report was equivocal in one case (0.6%), there were 16 false-negatives (9.1%), and one case was abandoned (0.6%). CONCLUSION: A sensitivity of 90.6% for radiographer-performed studies compared favourably with 89.7% for radiologist-performed studies and supports the practice of radiographers undertaking barium enemas. Culpan, D.G. et al. (2002)

  4. Virtual colonoscopy with electron beam CT: correlation with barium enema, colonoscopy and pathology

    International Nuclear Information System (INIS)

    Hong, Hye Suk; Kim, Min Jung; Chung, Jae Joon; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1998-01-01

    To perform virtual colonoscopy using electron beam tomography(EBT) in patients in whom a colonic mass was present, and to compare the results with those obtained using barium enema, colonoscopy and gross pathologic specimens. Materials and Methods : Ten patients in whom colonic masses were diagnosed by either barium enema or colonoscopy were involved in this study. There were nine cases of adenocarcinoma and one of tubulovillous adenoma. Using EBT preoperative abdominopelvic CT scans were performed. Axial scans were then three-dimensionally reconstructed to produce virtual colonoscopic images and were compared with barium enema, colonoscopy and gross pathologic specimens. Virtual colonoscopic images of the masses were classified as either 1)polyploid, 2)sessile,3)fungating, or 4)annular constrictive. We also determined whether ulcers were present within the lesions and whether there was obstruction. Results : After virtual colonoscopy, two lesions were classified as polyploid, one as sessile, five as fungating and two as annular constrictive. Virtual colonoscopic images showed good correlation with the findings of barium enema, colonoscopy and gross pathologic specimens. Three of six ulcerative lesions were observed on colonoscopy; in seven adenocarcinomas with partial or total luminal obstruction, virtual colonoscopy visualized the colon beyond the obstructed sites. In one case, barium contrast failed to pass through the obstructed portion and in six cases, the colonoscope similarly failed. Conclusion : Virtual colonoscopies correlated well with barium enema, colonoscopy and gross pathologic specimens. They provide three dimensional images of colonic masses and are helpful for the evaluation of obstructive lesions

  5. The effect of timing of intravenous muscle relaxant on the quality of double-contrast barium enema

    International Nuclear Information System (INIS)

    Elson, E.M.; Elson, E.M.; Campbell, D.M.; Halligan, S.; Shaikh, I.; Davitt, S.; Bartram, C.I.

    2000-01-01

    AIM: To determine whether the timing of buscopan administration during double-contrast barium enema examination (DCBE) affects diagnostic quality. MATERIALS AND METHODS: In a prospective setting, 100 consecutive adult out-patients referred for DCBE received 20 mg buscopan (hyoscine-N-butylbromide) intravenously, either before infusion of barium suspension (Group A) or after barium infusion and gas insufflation (Group B). A subjective assessment of ease of contrast medium infusion was made at the time of examination and the films subsequently analysed by two radiologists unaware of the mode of relaxant administration, who noted the quality of mucosal coating and made subjective and objective measurements of segmental distension. RESULTS: There was no significant difference in screening times, infusion difficulty or colonic contrast medium coating between the two groups. Subjective assessment of distension of the caecum, ascending colon, transverse colon and rectum were not significantly different. Patients receiving intravenous relaxant after barium and gas infusion had less subjective descending (P = 0.05) and sigmoid (P = 0.04) colon distension, but there was no significant difference with respect to maximal bowel diameter in any of the segments measured. CONCLUSION: The timing of intravenous administration during DCBE is likely to have no significant effect on the diagnostic quality of the study. Elson, E.M. (2000)

  6. Role of the double-contrast barium enema in rectal stenosis due to suppositories containing paracetamol and acetylsalicylic acid

    International Nuclear Information System (INIS)

    Tannouri, F.; Lalmand, B.; Zalcman, M.; Gansbeke, D. van; Gevenois, P.A.; Struyven, J.; Peny, M.O.; Gossum, A. van

    1998-01-01

    Self-treatment of chronic headache with suppositories containing paracetamol and acetylsalaicylic acid may lead to serious complications. We report the radiological features of five cases of rectal stenosis following the use of such suppositories. The role of the double-contrast barium enema in suggesting the diagnosis of this complication of a chronic and often unrecognized self-treatment is emphasized. (orig.)

  7. Limitations of combined flexible sigmoidoscopy and double contrast barium enema in patients with rectal bleeding

    International Nuclear Information System (INIS)

    Hixson, L.J.; Sampliner, R.E.; Chernin, M.; Amberg, J.; Kogan, F.; Veterans Administration Medical Center, Tucson, AZ

    1989-01-01

    Eighty-seven outpatients with non-massive rectal bleeding or asymptomatic positive fecal occult blood were evaluated with 35 cm flexible sigmoidoscopy, double contrast barium enema (DBCE) and colonoscopy. 82% had hemorrhoids and 35% harbored colorectal neoplasia. The combination of flexible sigmoidoscopy and DCBE missed none of 7 malignant lesions. However, 35% of benign polyps ≥ 1 cm and 60.5% of those < 1 cm were not detected by this combination. The presence of hemorrhoids should not prevent a search for colon neoplasia and colonoscopy is the preferred method. (orig.)

  8. Role of the double-contrast barium enema in rectal stenosis due to suppositories containing paracetamol and acetylsalicylic acid

    Energy Technology Data Exchange (ETDEWEB)

    Tannouri, F.; Lalmand, B.; Zalcman, M.; Gansbeke, D. van; Gevenois, P.A.; Struyven, J. [Department of Radiology, Hopital Erasme, University of Brussels (Belgium); Peny, M.O. [Department of Pathology, University of Brussels (Belgium); Gossum, A. van [Department of Gastroenterology, University of Brussels (Belgium)

    1998-09-01

    Self-treatment of chronic headache with suppositories containing paracetamol and acetylsalaicylic acid may lead to serious complications. We report the radiological features of five cases of rectal stenosis following the use of such suppositories. The role of the double-contrast barium enema in suggesting the diagnosis of this complication of a chronic and often unrecognized self-treatment is emphasized. (orig.) With 6 figs., 20 refs.

  9. A randomized prospective triaI comparing oral sodium phosphate with magnesium citrate in preparing of patients for double contrast barium enema

    International Nuclear Information System (INIS)

    Lee, Eun Joo; Lee, Sung Woo; Lee, Hyeon Kyeong; Yang, Chang Hun; Kim, Soon; Oh, Yoen Hee; Kim, Seung Hyeon

    2004-01-01

    The purpose of this study was to compare two bowel preparation agents, sodium phosphate solution with magnesium citrate solution. A total of 94 subjects that underwent a double-contrast barium enema were included in this study. Bowel preparation before performing the barium study was done by using a sodium phosphate solution in 47 subjects and by using a magnesium citrate solution in the other 47 subjects. We evaluated the presence or absence of side effects when using these bowel preparation agents. Two radiologist who were blinded to the type of bowel preparation evaluated the quality of bowel preparation at the colonic segments (ascending, descending, and sigmoid colon) on the radiographs obtained by double-contrast barium enema, with regard to stool cleansing, water retention, barium coating and bubble formation. The side effects, such as abdominal clamping pain, nausea, hunger pain and chill occurred more frequently in the sodium phosphate group than in the magnesium citrate group (p< 0.001). Stool retention was more frequently found in the magnesium citrate group (p< 0.001). However, no statistical difference was noted on the status of water retention and barium coating between two groups. Gas bubble formation was more commonly seen in the sodium phosphate group (p< 0.001). The sodium phosphate solution appeared to be more effective in cleansing the right colon (p=0.001). Sodium phosphate solution appears to be more effective for colonic cleansing, with a lower incidence of side effects, than when using magnesium citrate solution

  10. Assessment of patient exposure for barium enema examinations

    International Nuclear Information System (INIS)

    Bednarek, D.R.; Rudin, S.; Wong, R.

    1983-01-01

    Methods are described for the assessment of patient exposure during clinical fluoroscopic procedures. Values of the roentgen-area-product (RAP) and their distribution throughout the examination are presented for both single-contrast and double-contrast barium enema studies. The double-contrast procedure was measured to give 50% more radiation to the patient than the single-contrast procedure when the same size optical aperture is used between the intensifier and TV pick-up tube. However, it was possible to decrease the fluoroscopic RAP value by over a factor of two for the double-contrast procedure without an adverse clinical effect by increasing the area of the aperture diaphragm

  11. Benefits of Barium Enema in Patients with Incomplete Colonoscopy. Prospective Study of 45 Cases; Valor del enema de bario en pacientes con colonoscopia incompleta. Estudio prospectivo de 45 casos

    Energy Technology Data Exchange (ETDEWEB)

    Gispert, S.; Mayolas, N.; Hidalgo, A. [Hospital General Universitario Vall de Hebron. Barcelona (Spain)

    2003-07-01

    To evaluate the usefulness of barium enema in patients with incomplete colonoscopy. There was carried out a prospective 10-month study of 45 patients with incomplete colonoscopy (27 men and 18 women), who were later examined by means of barium enema (33 conventional, 12 double-contrast) in order to check for additional pathology in portions of the colon not visualized by colonoscopy. Barium enema diagnosed six possible additional lesions (13.3%) in portions of the colon not visualized by incomplete colonoscopy (four neoplasia and two non-neoplasia). Regarding the neoplasia two were true positives and two false positives. Both true positives were adenocarcinomas (one synchronous caecum, and another in splenic angle). The two false positives corresponded to fecal matter stuck to the intestinal wall. Regarding the non-neoplasia, multiple stenosis was detected in a patient with Crohn's disease and an enterocolic fistula was found in a patient with sigmoid colon neoplasia. The diagnostic yield of barium enema in the detection of additional pathology in colon portions not visualized by colonoscopy was of 9%. Barium enema following incomplete colonoscopy permits a complete colon evaluation in most cases, and it offers additional diagnostic information. (Author) 21 refs.

  12. Colonoscopy can miss diverticula of the left colon identified by barium enema.

    Science.gov (United States)

    Niikura, Ryota; Nagata, Naoyoshi; Shimbo, Takuro; Akiyama, Junichi; Uemura, Naomi

    2013-04-21

    To identify the diagnostic value of colonoscopy for diverticulosis as determined by barium enema. A total of 65 patients with hematochezia who underwent colonoscopy and barium enema were analyzed, and the diagnostic value of colonoscopy for diverticula was assessed. The receiver operating characteristic area under the curve was compared in relation to age (barium enema. Colonoscopy had a sensitivity of 91% and specificity of 90%. No significant differences were found in the receiver operating characteristic area under the curve (ROC-AUC) for age group or sex. The ROC-AUC of the left colon was significantly lower than that of the right colon (0.81 vs 0.96, P = 0.02). Colonoscopy identified 486 colonic diverticula, while barium enema identified 1186. The detection ratio for the entire colon was therefore 0.41 (486/1186). The detection ratio in the left colon (0.32, 189/588) was significantly lower than that of the right colon (0.50, 297/598) (P barium enema, only half the number of colonic diverticula can be detected by colonoscopy in the entire colon and even less in the left colon.

  13. Colonic diverticulosis: evaluation with double contrast barium enema

    International Nuclear Information System (INIS)

    Ko, Jae Kook; Lee, Jong Koo; Yun, Eun Joo; Moon, Hee Jung; Shin, Hyun Ja

    1997-01-01

    To evaluate the pattern of colonic diverticulosis according to age and sex, and recent trend. The authors retrospectively reviewed 120 cases of colonic diverticulosis in 1,020 patients who had undergone a double contrast barium enema examination between January 1st, 1993, and December 31st, 1995, and analyzed the frequency, size, multiplicity and anatomical site, according to age and sex. Diverticulum size was classified into one of three groups : less than 5mm, 5-10mm, over 10mm in diameter. The overall incidence of colonic diverticulosis was 120 cases among 1,020 patients(11.8%) with an incidence 5.3 times higher in males than in females. Peak incidence was in the fifth decade, with 19 cases (15.8%) among males, and after the sixth decade, with four cases(3.3%) among females. Mean age was 57.7 years. Diverticulum size of 5-10mm in diameter was predominant (2% of cases); average diameter was 5-6mm. The incidence of colonic diverticulosis was 5.1 times more frequent in the right colon (101 cases) than in the left (20 cases). The overall incidence of colonic diverticulosis has continually increased; in addition it has also recently increased slightly in left-sided colon. This is thought to be due to various factors, both congenital and acquired, including longer life with good health care, constipation, irritable bowel syndrome, stress and the tendency of eating patterns to more closely resemble those of the west

  14. Colonic diverticulosis: evaluation with double contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Jae Kook; Lee, Jong Koo; Yun, Eun Joo; Moon, Hee Jung; Shin, Hyun Ja [Korea Veterans Hospital, Seoul (Korea, Republic of)

    1997-02-01

    To evaluate the pattern of colonic diverticulosis according to age and sex, and recent trend. The authors retrospectively reviewed 120 cases of colonic diverticulosis in 1,020 patients who had undergone a double contrast barium enema examination between January 1st, 1993, and December 31st, 1995, and analyzed the frequency, size, multiplicity and anatomical site, according to age and sex. Diverticulum size was classified into one of three groups : less than 5mm, 5-10mm, over 10mm in diameter. The overall incidence of colonic diverticulosis was 120 cases among 1,020 patients(11.8%) with an incidence 5.3 times higher in males than in females. Peak incidence was in the fifth decade, with 19 cases (15.8%) among males, and after the sixth decade, with four cases(3.3%) among females. Mean age was 57.7 years. Diverticulum size of 5-10mm in diameter was predominant (2% of cases); average diameter was 5-6mm. The incidence of colonic diverticulosis was 5.1 times more frequent in the right colon (101 cases) than in the left (20 cases). The overall incidence of colonic diverticulosis has continually increased; in addition it has also recently increased slightly in left-sided colon. This is thought to be due to various factors, both congenital and acquired, including longer life with good health care, constipation, irritable bowel syndrome, stress and the tendency of eating patterns to more closely resemble those of the west.

  15. Is CT effective in diagnosing the acute appendicitis?: Focus on comparison of unenhanced CT with barium enema

    International Nuclear Information System (INIS)

    Choi, Seong Hee; Hahm, So Hee; Kang Jin Hwa; Moon, Jeong Hwa

    1994-01-01

    To evaluate the role of unenhanced CT in diagnosing the acute appendicitis. We retrospectively analyzed conventional contrast-enhanced abdominal CT scans of 197 normal patients and barium enemas of 26 out of the 197 patients. Additional unenhanced CT scans of right lower abdomen were performed on 30 patients who were suspected of having acute appendicitis; barium enema was performed in 26 patients. In the analysis of the conventional CT scans, we could detect 132 (67%) normal appendices. On barium enema of 26 out of 197 patients, abruptly narrowed appendix was visualized in 5 cases and luminal irregularity in 4 cases but all 26 cases showed normal appendix on CT. In the 30 cases of unenhanced CT, all appendices were visualized. Among 12 cases which were proved as acute appendicitis, barium enema was done in 10 cases; abruptly narrowed appendix was shown in 3 and luminal irregularity in 1. Among 18 cases which were diagnosed as normal appendix, nonvisualization of appendix was in 1 case, abruptly narrowed lumen in 3, and luminal irregularity in 9. Unenhanced CT in the area of the cecum may be an effective and safe diagnostic tool acute appendicitis

  16. Barium enema and CT volumetry for predicting pathologic response to preoperative chemoradiotherapy in rectal cancer patients.

    Science.gov (United States)

    Murono, Koji; Kawai, Kazushige; Tsuno, Nelson H; Ishihara, Soichiro; Yamaguchi, Hironori; Sunami, Eiji; Kitayama, Joji; Watanabe, Toshiaki

    2014-06-01

    Preoperative chemoradiotherapy has been widely used for the prevention of local recurrence of locally advanced rectal cancer, and the effect of chemoradiotherapy is known to be associated with overall survival. We aimed to evaluate the association of the pathologic response grade with tumor recurrence rate after chemoradiotherapy, using radiographic analysis and the Response Evaluation Criteria in Solid Tumors as the parameters. This study was conducted at a single tertiary care institution in Japan. This was a retrospective cohort study of patients undergoing preoperative chemoradiotherapy. A total of 101 low rectal cancer patients receiving preoperative chemoradiotherapy from July 2004 to August 2012 were enrolled. The tumor reduction rate was measured with the use of traditional Response Evaluation Criteria in Solid Tumors, barium enema, and CT volumetry, and the correlation between the reduction rate and the pathologic response grade was examined. The tumor reduction rate assessed according to Response Evaluation Criteria in Solid Tumors showed no association with the pathologic response grade (p =0.61). In contrast, the radiographic response rate by both barium enema and CT volumetry strongly correlated with the pathologic response grade (p volumetry had a lower recurrence rate (p =0.03, p =0.03, p =0.0002, and p =0.001). The difference between high responders and low responders was especially prominent by barium enema and CT volumetry. The study is limited by its retrospective nature. Double-contrast barium enema and CT volumetry were superior to Response Evaluation Criteria in Solid Tumors in evaluating the effect of chemoradiotherapy and predicting the likelihood of tumor recurrence.

  17. Barium enema and endoscopy for the detection of colorectal neoplasia: Sensitivity, specificity, complications and its determinants

    International Nuclear Information System (INIS)

    Zwart, Ingrid M. de; Griffioen, Gerrit; Shaw, M. Pertaap Chandie; Lamers, Cornelis B.H.W.; Roos, Albert de

    2001-01-01

    AIM: To analyse sensitivity, specificity and complication rate of endoscopy, and barium enema for the detection of colorectal neoplasia. MATERIALS AND METHODS: A MEDLINE search was performed (1980-2000) directed at the endoscopic and radiologic literature on barium enema. Articles were selected based on the type of study, availability of sensitivity and specificity values in sizeable patient groups, and reports on complications. Sixty articles were included in the analysis. RESULTS: Endoscopy proved to have superior sensitivity for polyps in patients at high-risk for colorectal neoplasia. The role of endoscopy and radiology in average-risk screening populations is not known. Sensitivity and specificity rates ranged widely, probably due to bias. For the detection of small polyps endoscopy has superior performance, whereas sensitivity is similar for endoscopy and barium enema for the detection of larger (>1 cm) polyps and tumours. Overall, endoscopy is associated with a higher complication rate. CONCLUSION: Endoscopy is the preferred detection method in high-risk patients. The role of endoscopy and radiology in a screening setting requires evaluation. This review provides the test characteristics of endoscopy and radiology which are relevant for a cost-effectiveness analysis. Double-contrast barium enema may play an important role for screening purposes, owing to its good sensitivity for detecting larger (>1 cm) polyps and its lack of major complications. Zwart, I.M. de et al. (2001)

  18. Selective use of the biphasic-contrast barium enema study for evaluation of colonic lesions: Results of a prospective study

    International Nuclear Information System (INIS)

    De Lange, E.E.; Shaffer, H.A. Jr.; Riddervold, H.O.

    1987-01-01

    The authors performed a prospective study to determine the value of selective use of the biphasic contrast technique for a variety of indications. In a series of 571 double-contrast barium enema examinations, the examination was immediately followed by a single-contrast study in 85 cases. The biphasic procedure was performed to reexamine a colonic segment that was poorly evaluated initially because of diverticulosis (eta = 35), incomplete filling (eta = 28), or poor mucosal coating (eta = 26); or to verify or exclude a possible lesion identified during the double-contrast examination (eta = 22). The single-contrast study confirmed five polyps and excluded lesions in 17 cases with suspected polyps (eta = 5), strictures (eta = 4), and spasm (eta = 8). Six polyps not visualized on the double-contrast examination were detected with the single-contrast procedure

  19. Small bowel volvulus in children. Its appearance on the barium enema examination

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, M.J.; Shackelford, G.D.; McAlister, W.H.

    1980-01-01

    Two children with small bowel volvulus diagnosed on barium enema examination are reported. In one patient the volvulus was associated with malrotation and in the other patient there was a post-operative peritoneal adhesion. In both cases the diagnosis was based on beaking of the head of the barium column at the site of volvulus. Radiographic demonstration of a beak sign in the small bowel on barium enema examination should suggest a diagnosis of small bowel volvulus, and indicates the need for immediate surgery.

  20. Degree of mucosal coating on double contrast barium enema : comparison of distilled water and normal saline as a suspension

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Lee, Dong Ho; Ko, Young Tae; Lim, Joo Won; Han, Tae Il; Kim, Hyoung Jung

    1997-01-01

    To evaluate the degree of mucosal coating on double contrast barium enema (DCBE), using barium suspension made with distilled water or normal saline Between June 1 and July 30, 1996, fifty-four patients prospectively underwent DCBE using 83% w/v(weight-to-volume) of barium suspension (room temperature, 24 deg C), which was made with 1,200mL of distilled water (Group 1;29cases) and normal saline (Group 2;25cases) per 1Kg of Solotop (Taejoon Pharmacy, Seoul, Korea). Bowel preparation and examination methods were the same in both groups, and four projections(erect view, supine view, both decubitus views) were taken. The mucosal coating was graded as excellent, good, ordinary, or poor by three radiologists working independently, and scored from 3 to 0. Significance was analyzed by t-test. Mean grading scores were 2.33±0.70 in group 1 and 1.56±0.99 in group 2 (P<0.003). When barium suspension made with distilled water was used, the degree of mucosal coating on DCBE was better than when the suspension was made with normal saline

  1. Lower GI Series (Barium Enema)

    Science.gov (United States)

    ... uses x-rays and a chalky liquid called barium to view your large intestine . The barium will make your large intestine more visible on ... single-contrast lower GI series, which uses only barium a double-contrast or air-contrast lower GI ...

  2. Assessing colonic anatomy normal values based on air contrast enemas in children younger than 6 years

    NARCIS (Netherlands)

    Koppen, Ilan J. N.; Yacob, Desale; Di Lorenzo, Carlo; Saps, Miguel; Benninga, Marc A.; Cooper, Jennifer N.; Minneci, Peter C.; Deans, Katherine J.; Bates, D. Gregory; Thompson, Benjamin P.

    2017-01-01

    Contrast enemas with barium or water-soluble contrast agents are sometimes performed in children with severe intractable constipation to identify anatomical abnormalities. However there are no clear definitions for normal colonic size or abnormalities such as colonic dilation or sigmoid redundancy

  3. DIAGNOSTIC ACCURACY OF BARIUM ENEMA FINDINGS IN HIRSCHSPRUNG'S DISEASE.

    Science.gov (United States)

    Peyvasteh, Mehran; Askarpour, Shahnam; Ostadian, Nasrollah; Moghimi, Mohammad-Reza; Javaherizadeh, Hazhir

    2016-01-01

    Hirschsprung's disease is the most common cause of pediatric intestinal obstruction. Contrast enema is used for evaluation of the patients with its diagnosis. To evaluate sensitivity, specificity, positive predictive value, and negative predictive value of radiologic findings for diagnosis of Hirschsprung in patients underwent barium enema. This cross sectional study was carried out in Imam Khomeini Hospital for one year starting from 2012, April. Sixty patients were enrolled. Inclusion criteria were: neonates with failure to pass meconium, abdominal distention, and refractory constipation who failed to respond with medical treatment. Transitional zone, delay in barium evacuation after 24 h, rectosigmoid index (maximum with of the rectum divided by maximum with of the sigmoid; abnormal if de Hirschsprung é a causa mais comum de obstrução intestinal pediátrica. Enema baritado é usado para a avaliação dos pacientes com o diagnóstico . Avaliar a sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo de achados radiológicos para diagnóstico de Hirschsprung em pacientes submetidos ao enema opaco. Este estudo transversal foi realizado em Imam Khomeini Hospital por um ano a partir de abril de 2012. Sessenta pacientes foram incluídos. Os critérios de inclusão foram: recém-nascidos com insuficiência de passagem de mecônio, distensão abdominal, e constipação refratária sem resposta ao tratamento médico. Foram avaliadas no enema zona de transição, atraso na evacuação de bário após 24 h, índice retossigmoide (máximo do diâmetro do reto dividido pelo máximo do sigmóide; anormal se casos com a doença de Hirschsprung e sem foi 17,90±18,29 meses e 17,8±18,34 meses, respectivamente (p=0,983). Confirmou-se em 30 (M=20, F=10) dos casos. Falha no mecônio foi encontrada em 21 (70%) casos. Sensibilidade, especificidade, VPP e VPN foram de 90%, 80%, 81,8% e 88,8%, respectivamente, para a zona de transição no enema

  4. Dose optimisation of double-contrast barium enema examinations.

    Science.gov (United States)

    Berner, K; Båth, M; Jonasson, P; Cappelen-Smith, J; Fogelstam, P; Söderberg, J

    2010-01-01

    The purpose of the present work was to optimise the filtration and dose setting for double-contrast barium enema examinations using a Philips MultiDiagnost Eleva FD system. A phantom study was performed prior to a patient study. A CDRAD phantom was used in a study where copper and aluminium filtration, different detector doses and tube potentials were examined. The image quality was evaluated using the software CDRAD Analyser and the phantom dose was determined using the Monte Carlo-based software PCXMC. The original setting [100 % detector dose (660 nGy air kerma) and a total filtration of 3.5 mm Al, at 81 kVp] and two other settings identified by the phantom study (100 % detector dose and additional filtration of 1 mm Al and 0.2 mm Cu as well as 80 % detector dose and added filtration of 1 mm Al and 0.2 mm Cu) were included in the patient study. The patient study included 60 patients and up to 8 images from each patient. Six radiologists performed a visual grading characteristics study to evaluate the image quality. A four-step scale was used to judge the fulfillment of three image quality criteria. No overall statistical significant difference in image quality was found between the three settings (P > 0.05). The decrease in the effective dose for the settings in the patient study was 15 % when filtration was added and 34 % when both filtrations was added and detector dose was reduced. The study indicates that additional filtration of 1 mm Al and 0.2 mm Cu and a decrease in detector dose by 20 % from the original setting can be used in colon examinations with Philips MultiDiagnost Eleva FD to reduce the patient dose by 30 % without significantly affecting the image quality. For 20 exposures, this corresponds to a decrease in the effective dose from 1.6 to 1.1 mSv.

  5. [Practical usage of a quality management system according to ISO 9001 : 2000 focusing on the double contrast (barium) enema].

    Science.gov (United States)

    Heinzle, G; Hergan, K; Fleisch, M; Hubmann, M; Oser, W

    2001-12-01

    We describe the implementation of quality improvement measures in a quality management system. With questionnaires for radiologists and patients, we investigated the relations between patient preparation and diagnostic quality serving the main purpose, to improve diagnostic quality with the help of more detailed patient information (e.g., changing preparation sheets and handling out "peri-med" information sheets to the patients). Furthermore, a comparative data ascertainment at other institutes was integrated. For the group of outpatients, increasing process quality (patient information) and outcome (diagnostic quality) could be achieved. Taking aspects of quality costs into consideration, a decrease in costs due to failures was achieved. More detailed patient information has positive effects on diagnostic quality of the double contrast (barium) enema.

  6. Rectal water contrast transvaginal ultrasound versus double-contrast barium enema in the diagnosis of bowel endometriosis.

    Science.gov (United States)

    Jiang, Jipeng; Liu, Ying; Wang, Kun; Wu, Xixiang; Tang, Ying

    2017-09-07

    The aim of study was to compare the accuracy between rectal water contrast transvaginal ultrasound (RWC-TVS) and double-contrast barium enema (DCBE) in evaluating the bowel endometriosis presence as well as its extent. 198 patients at reproductive age with suspicious bowel endometriosis were included. Physicians in two groups specialised at endometriosis performed RWC-TVS as well as DCBE before laparoscopy and both groups were blinded to other groups' results. Findings from RWC-TVS or DCBE were compared with histological results. The severity of experienced pain severity through RWC-TVS or DCBE was assessed by an analogue scale of 10 cm. In total, 110 in 198 women were confirmed to have endometriosis nodules in the bowel by laparoscopy as well as histopathology. For bowel endometriosis diagnosis, DCBE and RWC-TVS demonstrated sensitivities of 96.4% and 88.2%, specificities of 100% and 97.3%, positive prediction values of 100% and 98.0%, negative prediction values of 98.0% and 88.0%, accuracies of 98.0% and 92.4%, respectively. DCBE was related to more tolerance than RWC-TVS. RWC-TVS and DCBE demonstrated similar accuracies in the bowel endometriosis diagnosis; however, patients showed more tolerance for RWC-TVS than those with DCBE. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Iatrogen perforation of the rectum following barium enema

    International Nuclear Information System (INIS)

    Eggum, R.; Kressner, U.; Haffner, J.

    1998-01-01

    Perforation of the rectum following barium enema is relatively rare, occurring in 1 of 3,000 procedures. Colorectal perforation is a serious condition and early diagnosis is of paramount importance in order to avoid any delay in treating the patient. Direct suture of the perforation, lavage, presacral drainage and stomia are the preferred methods of primary surgical treatment. 10 refs., 1 fig

  8. Revaluation on detection of metastatic cancer of the colorectum with barium enema. Comparison with computed tomography and colonoscopy

    International Nuclear Information System (INIS)

    Watari, Jiro; Mizukami, Yusuke; Tanabe, Hirotaka

    1996-01-01

    The findings with barium enema were analyzed and compared to those with computed tomography and colonoscopy in 15 patients with metastatic cancer of the colorectum, which were from 8 gastric, 2 colonic, 2 ovarian, 1 pancreatic, 1 prostatic carcinomas and 1 unknown origin. Primary cancers of intra-abdominal cavity origin tended to make multiple colorectal metastases (91.7%). With barium enema colonic and rectal involvement was mostly expressed as the tethered type and the diffuse type by Ishikawa's classification, respectively. Computed tomography detected direct tumor invasion to the colorectum in 4 cases. Of the other 11 cases, 8 patients (72.3%) showed abnormally thickened colorectal wall. Colonoscopy detected only 3 (37.5%) out of 8 lesions seen in 4 patients who had undergone colonoscopy before barium enema. Many of the lesions missed were the tethered type involvement. Barium enema is the most sensitive method to detect metastatic cancer of the colorectum. (author)

  9. Evaluation of colonic involvement in endometriosis: double-contrast barium enema vs. magnetic resonance imaging.

    Science.gov (United States)

    Faccioli, N; Foti, G; Manfredi, R; Mainardi, P; Spoto, E; Ruffo, G; Minelli, L; Mucelli, R Pozzi

    2010-08-01

    The purpose of the study was to compare the accuracy of double-contrast barium enema (DCBE) and magnetic resonance imaging (MRI) in the diagnosis of intestinal endometriosis using the histological examination on resected specimen as comparative standard. Eighty-three consecutive patients with suspected intestinal endometriosis, resected between 2005 and 2007, were prospectively evaluated. All of the women underwent preoperative DCBE and MRI on the same day. We evaluated number, site (rectum, sigmoid, cecum), and size of the lesions. The imaging findings were correlated with those resulting at pathology. Among the 65 women who underwent surgery, 50/65 (76.9%) were found to have bowel endometriosis, with 9/50 (18%) patients presenting two lesions; DCBE allowed to detect 50/59 (84.7%) lesions. MRI allowed to detect 42/59 (71.1%) lesions. DCBE showed sensibility, specificity, PPV, NPV, and accuracy of respectively 84.7, 93.7, 98.0, 62.5, and 86.6%, MRI of 71.1, 83.3, 93.3, 46.8, and 74.6%. DCBE is more accurate than unenhanced MRI in the diagnosis of bowel endometriosis, and should be preferred in the preoperative management of this disease, since it usually enables a proper surgical planning.

  10. Radiation doses to patients undergoing barium meal and barium enema examinations

    International Nuclear Information System (INIS)

    Delichas, M. G.; Hatziioannou, K.; Papanastassiou, E.; Albanopoulou, P.; Chatzi, E.; Sioundas, A.; Psarrakos, K.

    2004-01-01

    The radiation doses received by patients during 41 barium meal (BM) and 42 barium enema (BE) examinations in two Greek hospitals are presented. Radiation dose was measured in terms of the dose area product (DAP). The effective dose and doses to certain organs were estimated using the ODS-60 software. Mean total DAP values were found to be 25 ± 11 Gy cm 2 for BM and 60 ± 35 Gy cm 2 for BE examinations, whereas the estimated mean values of effective dose were 8.6 ± 4.0 and 24 ± 16 mSv respectively. DAP to effective dose conversion coefficients were estimated to be 0.34 mSv per Gy cm 2 for BM and 0.41 mSv per Gy cm 2 for BE. (authors)

  11. Choice of double contrast barium enema (DCBE) method based on patient exposure dose

    Energy Technology Data Exchange (ETDEWEB)

    Bartal, G; Ben Hasid, I [Hillel Yaffe Medical Center, Hadera (Israel)

    1997-11-16

    Morbidity of colon cancer continues to increase, taking second and third places in malignant tumors. The incidence of colorectal cancer (CRC) increases exponentially with age; those over 50 years of age represent 37% of general population, yet account for 95% of the cases, and more than 96% of the deaths from colon malignancies For a long time radiologic examinations were considered as a main pre-operative diagnostic method for cancer of the colon. The sensitivity of the barium enema with regard to diagnosis of the carcinoma and polyps ranges from 92-98.5%. Sigmoidoscopy for detection and removal of polyps has been shown to decrease the incidence of subsequent CRC`s by 70-80% in distal colon. However, the sigmoid colon is often difficult to examine because of associated diverticular disease, and about 15% of tumors in the sigmoid colon are overlooked. (Authors)

  12. Choice of double contrast barium enema (DCBE) method based on patient exposure dose

    International Nuclear Information System (INIS)

    Bartal, G.; Ben Hasid, I.

    1997-01-01

    Morbidity of colon cancer continues to increase, taking second and third places in malignant tumors. The incidence of colorectal cancer (CRC) increases exponentially with age; those over 50 years of age represent 37% of general population, yet account for 95% of the cases, and more than 96% of the deaths from colon malignancies For a long time radiologic examinations were considered as a main pre-operative diagnostic method for cancer of the colon. The sensitivity of the barium enema with regard to diagnosis of the carcinoma and polyps ranges from 92-98.5%. Sigmoidoscopy for detection and removal of polyps has been shown to decrease the incidence of subsequent CRC's by 70-80% in distal colon. However, the sigmoid colon is often difficult to examine because of associated diverticular disease, and about 15% of tumors in the sigmoid colon are overlooked. Authors)

  13. Randomized clinical trial on the use of antispasmodic drugs in barium enema: impact on radiological practice

    International Nuclear Information System (INIS)

    Goei, Reginald; Kessels, Alphons H.; Nix, Maarten; Knipschild, Paul G.

    2000-01-01

    Purpose: To assess the willingness of radiologists to change their practice when the results of a randomized clinical trial (RCT) on the use of antispasmodic drugs in barium enema are presented. Materials and Methods: During the years 1994 and 1995 two postal questionnaires were sent to 481 practicing radiologists who were all members of the Netherlands Society of Radiology. In the first questionnaire the respondents were asked to give the characteristics of their practices in performing daily barium enema. The data from this questionnaire was used as a reference. The second questionnaire was sent to the respondents together with an abstract on the randomized clinical trial supporting the use of antispasmodic drugs in barium enema. We also indicated a preference for Buscopan over Glucagon as the antispasmodic drug. The willingness to change prescription habits was measured by comparing the data of the two questionnaires. Results: Of 481 practicing radiologists, 312 responded to the first questionnaire and gave information of their prescription habits (response rate 64%). These 312 responders were sent an abstract of the RCT and were asked to fill out a second questionnaire to determine their willingness to change their practice. Two hundred and sixty-seven radiologists responded (response rate 86%). A significant number of 119 (51%) were willing to increase the use of antispasmodic drugs. A significant number of 128 (55%) chose to increase the use of Buscopan, while a significant number of 81 (32%) were willing to decrease the use of Glucagon. Conclusion: Direct exposure to the results of an RCT recommending the use of antispasmodic drugs in barium enema, especially Buscopan, is likely to increase its use by practicing radiologists

  14. How changes in a radiologist's technique can reduce patient dose in barium enema studies

    International Nuclear Information System (INIS)

    Corbett, R.H.

    2001-01-01

    Changes in a radiologist's technique, especially utilising digital technology, can lead to substantial dose savings in barium enema examinations. Data will be provided showing a 20% saving with only minimal change in technique. (author)

  15. Barium enema and CT findings of Douglas pouch metastasis

    International Nuclear Information System (INIS)

    Miyakawa, Kunihisa; Uchiyama, Nachiko; Iinuma, Hajime; Moriyama, Noriyuki

    1999-01-01

    We retrospectively reviewed barium enema and CT findings of Douglas pouch metastasis in 170 patients. The findings were divided into three types: Anterior compression type, anterior fixed folds type, and stenosis type. Patients with gastric cancer usually showed a stenosis type, especially in those with poorly differentiated adenocarcinoma. Patients with colon and ovary cancer usually showed an anterior compression type. In patients with gastric cancer, those who showed a stenosis type had the most favorable prognosis among these three types. (author)

  16. Double-contrast barium enema in the diagnosis of intestinal deeply infiltrating endometriosis

    OpenAIRE

    Ribeiro, Helizabet Salomão Abdalla Ayroza; Ribeiro, Paulo Augusto Ayroza Galvão; Rodrigues, Francisco César; Donadio, Nilson; Auge, Antônio Pedro Flores; Aoki, Tsutomu

    2008-01-01

    OBJETIVO: avaliar a sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo do enema de bário com duplo contraste (EBDC) para o diagnóstico da endometriose do reto e sigmóide. MÉTODOS: estudo transversal prospectivo que incluiu 37 pacientes com quadro clínico suspeito de endometriose profunda. As pacientes foram submetidas ao EBDC de acordo com a técnica padrão descrita na literatura. Em seguida, foram submetidas à laparoscopia. Os exames foram realizados e seus res...

  17. CT colonography versus double-contrast barium enema for screening of colorectal cancer: comparison of radiation burden.

    Science.gov (United States)

    Neri, Emanuele; Faggioni, Lorenzo; Cerri, Francesca; Turini, Francesca; Angeli, Simone; Cini, Lorenzo; Perrone, Franco; Paolicchi, Fabio; Bartolozzi, Carlo

    2010-10-01

    Our aim is to compare the radiation dose associated with a low-dose CT colonography (CTC) protocol for colorectal cancer screening with that delivered by double-contrast barium enema (DCBE). CTC of twenty asymptomatic individuals (M:F = 10:10) participating to a colorectal cancer screening program and DCBE of fifteen patients (M:F = 6:9) were evaluated. For CTC, absorbed dose was determined by calculating the dose-length product for each CTC examination from measurements on a CT dose phantom equipped with a CT ion chamber. For DCBE, the free-in-air Kerma at the patient's X-ray entry surface and the Kerma-area product during fluoroscopy and fluorography were measured with a Barracuda system, with fluoroscopy times being recorded blinded to the performing operator. Effective dose at CTC was 2.17 ± 0.12 mSv, with good and excellent image quality in 14/20 (70%) and 6/20 cases (30%), respectively. With DCBE, effective patient dose was 4.12 ± 0.17 mSv, 1.9 times greater than CTC (P < 0.0001). Our results show that effective dose from screening CTC is substantially lower than that from DCBE, suggesting that CTC is the radiological imaging technique of the large bowel with the lowest risk of stochastic radiation effects.

  18. Barium granuloma of the rectum: case report

    International Nuclear Information System (INIS)

    Kim, Dae Jin; Kim, Se Hyung; Jeoung, Ah Young; Lee, Kyoung Ho; Choi, Byung Ihn; Han, Joon Koo

    2003-01-01

    Barium granulomas usually occur after barium enema within 8 cm of the anal verge probably due to minute laceration of rectal wall by enema tip and extravasation of barium during barium enema. We report a case of barium granuloma of rectum in a 47-year-old man, who did not have history of barium enema. In rare instance, barium granuloma can occur without a history of barium enema and careful interpretation of radiologic image is essential to make a correct diagnosis

  19. Barium enema in frail elderly patients.

    Science.gov (United States)

    Segal, R; Khahil, A; Leibovitz, A; Gil, I; Annuar, M; Habot, B

    2000-01-01

    Barium enema (BE) examinations for the investigation of suspected colonic disease are often unsuccessful in elderly patients. The purpose of this study was to evaluate the success rate of BE in hospitalized frail elderly patients. Four hundred and seventy-two elderly patients hospitalized for different reasons underwent BE examinations. The medical charts and radiological reports were retrospectively reviewed. One hundred and ninety-two (41%) BE examinations were considered inadequate; mostly (32%) because of inappropriate preparation. Sixty-seven patients (14%) were not cooperative and could not retain the contrast material, and in 25 patients (5%), the examination failed due to both these reasons. The characteristics associated with unsuccessful BE examination were the mean number of medical problems (p < 0.001), the mean number of scheduled medications (p < 0.05) and in particular the long-term use of laxatives (p < 0.01) or antiparkinsonian drugs (p < 0.01). Of great significance in predicting an inadequate BE were the patient's functional status (p < 0.001) and the presence of dementia (p < 0.001). The high percentage of unsuccessful BEs in the frail elderly suggests that clinicians should carefully consider the need for that examination in these patients. We suggest that only in patients where there is a clear suspicion of a bleeding or obstructing tumor should a BE examination be performed, and even in these cases, colonoscopy or CT may be preferable as the initial examination in the frail elderly. Copyright 2000 S. Karger AG, Basel

  20. Assessing colonic anatomy normal values based on air contrast enemas in children younger than 6 years.

    Science.gov (United States)

    Koppen, Ilan J N; Yacob, Desale; Di Lorenzo, Carlo; Saps, Miguel; Benninga, Marc A; Cooper, Jennifer N; Minneci, Peter C; Deans, Katherine J; Bates, D Gregory; Thompson, Benjamin P

    2017-03-01

    Contrast enemas with barium or water-soluble contrast agents are sometimes performed in children with severe intractable constipation to identify anatomical abnormalities. However there are no clear definitions for normal colonic size or abnormalities such as colonic dilation or sigmoid redundancy in children. To describe characteristics of colonic anatomy on air contrast enemas in children without constipation to provide normal values for colonic size ratios in children. We performed a retrospective chart review of children aged 0-5 years who had undergone air contrast enemas for intussusception. The primary outcome measures were the ratios of the diameters and lengths of predetermined colonic segments (lengths of rectosigmoid and descending colon; diameters of rectum, sigmoid, descending colon, transverse colon and ascending colon) in relation to the L2 vertebral body width. We included 119 children (median age 2.0 years, range 0-5 years, 68% boys). Colonic segment length ratios did not change significantly with age, although the differences for the rectosigmoid/L2 ratio were borderline significant (P = 0.05). The ratios that involved the rectal and ascending colon diameters increased significantly with age, while diameter ratios involving the other colonic segments did not. Differences by gender and race were not significant. These data can be used for reference purposes in young children undergoing contrast studies of the colon.

  1. An evaluation of a radiographer-led barium enema service in the diagnosis of colorectal cancer

    International Nuclear Information System (INIS)

    Law, R.L.; Slack, N.F.; Harvey, R.F.

    2008-01-01

    Purpose: This study was undertaken to assess the sensitivity and efficacy of a radiographer-led double contrast barium enema (DCBE) service in the diagnosis of colorectal cancer (CRC). Methods: All patients on the CRC database from its inception in 1997 until the end of 2004 were cross-referenced with the radiology database. Details were recorded of any patient who had undergone a DCBE examination at any time prior to histological confirmation of colorectal cancer. All the DCBE in this review were performed and reported by radiographers as part of a protocol of double reporting with a consultant radiologist. The radiographers and radiologists reports were reviewed for each patient. Notes and X-rays were also reviewed when necessary. Reporting sensitivity was compared with the Royal College of Radiologists (RCR) barium enema examination targets for the diagnosis of colorectal carcinoma. Results: 362 of the 1005 patients on the CRC database had undergone a DCBE. Combined radiographer and radiologist reporting demonstrated a diagnostic sensitivity of 98% for CRC and were cancer specific in 93% of cases. These results compared favourably with the referenced RCR sensitivity targets for colorectal cancer. Reporting discord only occurred with the terminology of reporting 13 equivocal polyps. None of these polyps were neoplastic and thus did not affect CRC sensitivity. Conclusion: Radiographer reporting compares favourably with published CRC sensitivity data of more expensive techniques such as CT colonography. A protocol of radiographer/radiographer double reporting is now used at this hospital with radiological second opinion being acquired for more complex abnormal DCBE examination appearances. This service is a safe, cost-effective option that should not be overlooked with the increasing demand for CRC screening

  2. Preliminary evaluation of helical CT colonography in detection of colonic diseases compared with double contrast barium enema

    International Nuclear Information System (INIS)

    Zhai Xiaoli; Zhang Lei; Zhai Renyou; Li Jie; Wang Yajie; Ding Yi

    2000-01-01

    Objective: To evaluate helical CT colonography in regard to technology principles, limitations, and clinical applications. Methods: Fifty-six patients underwent volume scanning using helical CT. The diseases included adenocarcinoma 39, adenomatous polyp 3, multiple diverticular 7, mucocele of appendix 1, and normal colon 6. All cases had been compared with double contrast barium enema (DCBE), proved by histology except the 6 normal colon and the 7 multiple diverticular. All CTC images were reconstructed using shaded surface display (SSD) on workstation. Then, perspective images such as the ones from DCBE were generated via ray sum. The images could clearly demonstrate the extent and detail of the disorder by using 'CUT' software, 'revolve' function, and zoom. Results: CTC correctly demonstrated 3-5 mm diverticulum, 3 mm ulcer, and 6 mm polyps. Not only show colon straitness clearly, CTC is also very sensitive to demonstrate the stenotic end of masses. In these cases, discovery rate of CTC is 100.0%, the rate of DCBE is 88.6%; CTC is more sensitive than DCBE in cases of tumor nodules. Ray sum can show the boundary of colonic mass extending to both proximal and distal ends, its discovery rate is 62.6%. Accuracy of localization for CTC is 100.0%. Conclusion: CTC is a novel technique for detecting colonic diseases. It is a safe, accurate, and non-invasive means for detection of lesions and is an efficient complement for DCBE. Further development in CTC technique is expected in the future

  3. Polysorbate 80 and low-osmolality water-soluble contrast medium enema in diagnosis and treatment of faecal obstruction in malignant phaeochromocytoma

    International Nuclear Information System (INIS)

    Ratcliffe, J.F.

    1986-01-01

    Stercoral obstruction in a young woman with disseminated phaeochromocytoma was diagnosed and treated successfully using an enema of isosmolar iohexol (Omnipaque) and 1% polysorbate 80 (Tween 80) without complication. Surgical intervention was thus avoided. A low osmolality water-soluble contrast medium (iohexol 150 mg I/ml) with a wetting agent (1% Tween 80) was used because a barium suspension would have inspissated, exacerbating the constipation and a hyperosmolar contrast medium might have precipitated a hypertensive crisis and destablished her critical salt and water balance. (orig.)

  4. Iatrogen perforation of the rectum following barium enema; Iatrogen perforasjon av rectum ved roentgen colon

    Energy Technology Data Exchange (ETDEWEB)

    Eggum, R.; Kressner, U.; Haffner, J. [Buskerud Central Hospital, Drammen (Norway)

    1998-05-01

    Perforation of the rectum following barium enema is relatively rare, occurring in 1 of 3,000 procedures. Colorectal perforation is a serious condition and early diagnosis is of paramount importance in order to avoid any delay in treating the patient. Direct suture of the perforation, lavage, presacral drainage and stomia are the preferred methods of primary surgical treatment. 10 refs., 1 fig.

  5. Comparison between CT Colonography and Double-Contrast Barium Enema for Colonic Evaluation in Patients with Renal Insufficiency

    International Nuclear Information System (INIS)

    Chung, Sun Young; Park, Seong Ho; Lee, Seung Soo; Lee, Ju Hee; Kim, Ah Young; Park, Su Ki; Han, Duck Jong; Ha, Hyun Kwon

    2012-01-01

    To compare the CT colonography (CTC) and double-contrast barium enema (DCBE) for colonic evaluation in patients with renal insufficiency. Two sequential groups of consecutive patients with renal insufficiency who had a similar risk for colorectal cancer, were examined by DCBE (n = 182; mean ± SD in age, 51 ± 6.4 years) and CTC (n = 176; 50 ± 6.7 years), respectively. CTC was performed after colon cleansing with 250-mL magnesium citrate (n = 87) or 4-L polyethylene glycol (n = 89) and fecal tagging. DCBE was performed after preparation with 250-mL magnesium citrate. Patients with colonic polyps/masses of ≥ 6 mm were subsequently recommended to undergo a colonoscopy. Diagnostic yield and positive predictive value (PPV) for colonic polyps/masses, examination quality, and examination-related serum electrolyte change were retrospectively compared between the two groups. Both the CTC and DCBE were positive for colonic polyps/masses in 28 (16%) of 176 and 11 (6%) of 182 patients, respectively (p = 0.004). Among patients with positive findings, 17 CTC and six DCBE patients subsequently underwent a colonoscopy and yielded a PPV of 88% (15 of 17 patients) and 50% (3 of 6 patients), respectively (p = 0.089). Thirteen patients with adenomatous lesions were detected in the CTC group (adenocarcinoma [n = 1], advanced adenoma [n = 6], and non-advanced adenoma [n = 6]), as compared with two patients (each with adenocarcinoma and advanced adenoma) in the DCBE group (p = 0.003). Six (3%) of 176 CTC and 16 (9%) of 182 DCBE examinations deemed to be inadequate (p 0.046). Electrolyte changes were similar in the two groups. In patients with renal insufficiency, CTC has a higher diagnostic yield and a marginally higher PPV for detecting colorectal neoplasia, despite a similar diagnostic yield for adenocarcinoma, and a lower rate of inadequate examinations as compared with DCBE.

  6. Comparison between CT colonography and double-contrast barium enema for colonic evaluation in patients with renal insufficiency.

    Science.gov (United States)

    Chung, Sun-Young; Park, Seong Ho; Lee, Seung Soo; Lee, Ju Hee; Kim, Ah Young; Park, Su-Kil; Han, Duck Jong; Ha, Hyun Kwon

    2012-01-01

    To compare the CT colonography (CTC) and double-contrast barium enema (DCBE) for colonic evaluation in patients with renal insufficiency. Two sequential groups of consecutive patients with renal insufficiency who had a similar risk for colorectal cancer, were examined by DCBE (n = 182; mean ± SD in age, 51 ± 6.4 years) and CTC (n = 176; 50 ± 6.7 years), respectively. CTC was performed after colon cleansing with 250-mL magnesium citrate (n = 87) or 4-L polyethylene glycol (n = 89) and fecal tagging. DCBE was performed after preparation with 250-mL magnesium citrate. Patients with colonic polyps/masses of ≥ 6 mm were subsequently recommended to undergo a colonoscopy. Diagnostic yield and positive predictive value (PPV) for colonic polyps/masses, examination quality, and examination-related serum electrolyte change were retrospectively compared between the two groups. Both the CTC and DCBE were positive for colonic polyps/masses in 28 (16%) of 176 and 11 (6%) of 182 patients, respectively (p = 0.004). Among patients with positive findings, 17 CTC and six DCBE patients subsequently underwent a colonoscopy and yielded a PPV of 88% (15 of 17 patients) and 50% (3 of 6 patients), respectively (p = 0.089). Thirteen patients with adenomatous lesions were detected in the CTC group (adenocarcinoma [n = 1], advanced adenoma [n = 6], and non-advanced adenoma [n = 6]), as compared with two patients (each with adenocarcinoma and advanced adenoma) in the DCBE group (p = 0.003). Six (3%) of 176 CTC and 16 (9%) of 182 DCBE examinations deemed to be inadequate (p = 0.046). Electrolyte changes were similar in the two groups. In patients with renal insufficiency, CTC has a higher diagnostic yield and a marginally higher PPV for detecting colorectal neoplasia, despite a similar diagnostic yield for adenocarcinoma, and a lower rate of inadequate examinations as compared with DCBE.

  7. Comparison of transvaginal sonography and double-contrast barium enema for diagnosing deep infiltrating endometriosis of the posterior compartment.

    Science.gov (United States)

    Savelli, L; Manuzzi, L; Coe, M; Mabrouk, M; Di Donato, N; Venturoli, S; Seracchioli, R

    2011-10-01

    To compare the diagnostic accuracy of transvaginal sonography (TVS) and double-contrast barium enema (DCBE) in the preoperative detection of deep infiltrating endometriosis (DIE) of the posterior compartment. This was a prospective study of 69 consecutive patients with results of pelvic examination or symptoms suggestive of DIE of the posterior compartment. TVS and DCBE were performed before surgery by two groups of physicians specialized in endometriosis, each blinded to the results of the other technique. Imaging data were compared with histopathologic analysis of the resected specimen (gold standard). Sensitivity, specificity, positive and negative predictive values and test accuracies were calculated for both imaging modalities. Sixty seven of the 69 women had a nodule of DIE confirmed at laparoscopy and histopathologic examination. TVS diagnosed DIE in 57 (85%) of these patients, while DCBE revealed the presence of the lesion in 24 (36%) women. For the diagnosis of posterior DIE, TVS and DCBE had, respectively, a sensitivity of 85% and 36%, specificity of 100% and 100%, positive predictive value of 100% and 100%, negative predictive value of 17% and 4% and accuracy of 85.5% and 38%. In patients with pure bowel DIE the sensitivity was 91% and 43%, specificity was 100% and 100%, positive predictive value was 100% and 100%, negative predictive value was 29% and 6% and accuracy was 91% and 45%, respectively. TVS has a much higher sensitivity than does DCBE in detecting the presence of posterior DIE and should thus be regarded as the imaging modality of choice when there is clinical suspicion of the disease. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  8. Aspiration of Barium Contrast

    Directory of Open Access Journals (Sweden)

    Cristina Fuentes Santos

    2014-01-01

    Full Text Available The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical file was reviewed, images were found of a barium swallow study that the patient had undergone months earlier, and we were able to observe the exact moment of the aspiration of the contrast material. The patient had been asymptomatic since the test.

  9. Comparison of three contrast radiographic techniques in the dog large intestine

    International Nuclear Information System (INIS)

    Vargas, L.; Thibaut, J.; Olhaberry, E.; Born, R.; Deppe, R.

    1994-01-01

    In order to compare three radiographic techniques -pneumocolon, barium enema and double contrast- in the large intestine of the dog, three radiographic series in ventrodorsal and right lateral projections were taken. Six healthy adult dogs of both sexes with an approximate weight between 5 to 10 kg were used. Three enemas were administered 24, 12 and 2 hrs. before the series of radiographs were taken. Then dogs were anaesthetized with sodium tiopental (20 mg/kg iv) and the contrast media were introduced. Pneumocolon was carried out in the first series introducing air (20 cc/kg) in the large intestine through a Foley rectal catheter. Radiographs were taken in both projections, after 5 and 15min. respectively. Barium enema was performed in the second series introducing barium sulfate (18%) in the large intestine through a Foley rectal catheter (25 cc/kg); 5 and 15 min. later, the radiographs were taken. In the third series -double contrast- the barium sulfate, which was obtained from each dog using a catheter, was substituted by a volume of air equal to that obtained from the contrast medium. Later the radiographs were taken in both projections. The radiographic plates of each series were analized comparing the characteristics of: radiographic density, outline and volume. With the pneumocolon barium enema and double contrast, the radiographic density was, in most cases, low, high and inter-mediate respectively. The radiographic outline was, in most cases, regular for the three techniques. Thee radiographic volume was similar in all of the series. From the results obtained, it is concluded that double contrast best outlines the intestinal mucosa and more information can be obtained from it [es

  10. Prevention of crackle in double contrast examinations of the colon

    International Nuclear Information System (INIS)

    Carvalho, A. de; Madsen, B.

    1981-01-01

    Crackle of the barium contrast during double contrast examinations of the colon probably results from a drying effect due to resoption of water. The duration of the examination should therefore be kept as short as possible and the patient should be well hydrated. The tendency to crackle can be decreased by increasing the molality of the barium enema by suspending barium contrast in 0.4% saline. (Auth.)

  11. Post double-contrast sigmoid flush: An adjuvant technique in imaging diverticular disease

    International Nuclear Information System (INIS)

    Lappas, J.C.; Maglinte, D.D.T.; Kopecky, K.K.; Cockerill, E.M.; Lehman, G.A.

    1987-01-01

    In a prospective study, the effect of a low-density contrast medium infusion was evaluated as an adjunct to high-density double-contrast medium sigmoid imaging. Following a double-contrast medium barium enema (DCBE), 52 consecutive patients with sigmoid diverticulosis received an additional 500-700-mL enema with either water or a 1.5%CT barium suspension. Rectosigmoid films were evaluated for luminal distention, visualization of the interhaustral space, definition of diverticula, and interpretation of polypoid defects. While double-contrast medium views were excellent in 21%, improvement in multiple factors by water or 1.5% barium flush resulted in improved sigmoid images in 65% and 73% of patients, respectively. Polyps may be confirmed and artifactual defects confidently excluded. Sigmoid flush, particularly with low-density barium, is a simple adjunct to DCBE that improves visualization of the diverticular sigmoid

  12. Post-double-contrast sigmoid flush: An adjuvant technique in imaging diverticular disease

    International Nuclear Information System (INIS)

    Lappas, J.C.; Maglinte, D.D.T.; Kopecky, K.K.; Cockerill, E.M.; Lehman, G.A.

    1987-01-01

    The sigmoid colon is the most difficult colonic segment to examine radiographically, especially when it is involved by diverticular disease. In a prospective study, infusion of a low-density contrast agent was evaluated as an adjuvant technique to high-density double-contrast sigmoid imaging. After a double-contrast barium enema, 52 consecutive patients with sigmoid diverticulosis received an additional 500-ml enema either with water or with a 1.5% CT barium suspension. Rectosigmoid films were compared and evaluated for luminal distention, visualization of the interhaustral space, definition of diverticula, and display of polypoid defects. Sigmoid flush, particularly with the 1.5% CT barium suspension, is a simple adjunct to the double-contrast examination that improves visualization of the diverticular sigmoid and increases diagnostic specificity

  13. Renal excretion of water-soluble contrast media after enema in the neonatal period.

    Science.gov (United States)

    Kim, Hee Sun; Je, Bo-Kyung; Cha, Sang Hoon; Choi, Byung Min; Lee, Ki Yeol; Lee, Seung Hwa

    2014-08-01

    When abdominal distention occurs or bowel obstruction is suspected in the neonatal period, a water-soluble contrast enema is helpful for diagnostic and therapeutic purposes. The water-soluble contrast medium is evacuated through the anus as well as excreted via the kidneys in some babies. This study was designed to evaluate the incidence of renal excretion after enemas using water-soluble contrast media and presume the causes. Contrast enemas using diluted water-soluble contrast media were performed in 23 patients under 2 months of age. After the enema, patients were followed with simple abdominal radiographs to assess the improvement in bowel distention, and we could also detect the presence of renal excretion of contrast media on the radiographs. Reviewing the medical records and imaging studies, including enemas and consecutive abdominal radiographs, we evaluated the incidence of renal excretion of water-soluble contrast media and counted the stay duration of contrast media in urinary tract, bladder, and colon. Among 23 patients, 12 patients (52%) experienced the renal excretion of water-soluble contrast media. In these patients, stay-in-bladder durations of contrast media were 1-3 days and stay-in-colon durations of contrast media were 1-10 days, while stay-in-colon durations of contrast media were 1-3 days in the patients not showing renal excretion of contrast media. The Mann-Whitney test for stay-in-colon durations demonstrated the later evacuation of contrast media in the patients with renal excretion of contrast media (p = 0.07). The review of the medical records showed that 19 patients were finally diagnosed as intestinal diseases, including Hirschsprung's disease, meconium ileum, meconium plug syndrome, and small bowel atresia or stenosis. Fisher's exact test between the presence of urinary excretion and intestinal diseases indicated a statistically significant difference (p = 0.04). The intestinal diseases causing bowel obstruction may increase the

  14. Preoperative assessment of intestinal endometriosis: A comparison of transvaginal sonography with water-contrast in the rectum, transrectal sonography, and barium enema.

    Science.gov (United States)

    Bergamini, Valentino; Ghezzi, Fabio; Scarperi, Stefano; Raffaelli, Ricciarda; Cromi, Antonella; Franchi, Massimo

    2010-12-01

    To evaluate the accuracy of Transrectal Sonography (TRS) and a new technique, Transvaginal Sonography with Water-Contrast in the Rectum (RWC-TVS), in the diagnosis of rectosigmoid endometriosis, and the accuracy of Barium Enema (BE) and RWC-TVS in the detection of intestinal stenosis due to endometriosis. In a prospective study, we compared the findings of TRS and RWC-TVS performed before surgery with the operative and pathologic findings in 61 consecutive patients who underwent laparoscopy or laparotomy for suspected rectosigmoid endometriosis. The accuracy of BE and RWC-TVS in the detection of intestinal stenosis was evaluated comparing the radiologic and ultrasonographic results with the macroscopic findings at surgery and pathology. RWC-TVS diagnosed rectosigmoid endometriosis with the same accuracy of TRS and was equally efficient as BE in the detection of a significant intestinal lumen stenosis. For the diagnosis of rectosigmoid endometriosis the sensitivity, specificity, positive and negative predictive values of TRS and RWC-TVS were 88.2% and 96%, 80%, and 90%, 95.7%, and 98%, and 57.1% and 81.8%, respectively. For the detection of intestinal stenosis the sensitivity, specificity, positive and negative predictive values of BE and RWC-TVS were 93.7% and 87.5%, 94.2% and 91.4%, 88.2% and 82.3%, and 97% and 94.1%, respectively. RWC-TVS is a new, simple technique for a single-step and accurate preoperative assessment of rectosigmoid endometriosis.

  15. Aspiration of Barium Contrast

    OpenAIRE

    Fuentes Santos, Cristina; Steen, Bárbara

    2014-01-01

    The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical fil...

  16. The change of radiation doses to the patient when switching from conventional technique to digital technique without films in barium enema and IVU examinations. Final report SSI research project P933

    CERN Document Server

    Sjöholm, B

    2003-01-01

    X-ray examinations of the colon (barium enema) and the kidneys (IVU) are combined with rather high radiation doses to the patients when using analogue technique with film-screen systems. It is therefore of great interest to see if the change from analogue to digital technique involves a reduction of doses. Barium enema and IVU examinations were monitored with DAP-meters before and after the X-ray department changed to digital techniques. For IVU also the change from storage phosphor plates to a Direct Digital detector is included. The study comprises between 53 and 87 patients for each modality of the two examinations. A considerable dose reduction was observed. In barium enema the overview images with large field sizes were omitted when using digital technique. On the other hand the number of spot images was increased from 6 to 22. The fluoroscopy time was increased from 4 minutes to 6 minutes. The DAP value was reduced from 54,3 Gy cm sup 2 to 21,9 Gy cm sup 2. For IVU a dose reduction from 44,5 Gy cm sup 2...

  17. Double contrast barium meal and acetylcysteine

    International Nuclear Information System (INIS)

    Kinnunen, J.; Pietilae, J.; Ahovuo, J.; Mankinen, P.; Tervahartiala, P.

    1989-01-01

    In a prospective double blind study, acetylcysteine, a local and systemic respiratory tract mucolytic agent, or a placebo, were given to 100 patients prior to a double contrast barium meal to decrease the gastric mucus viscosity and to make the mucus layer thinner, in order to permit barium to outline the furrows surrounding the areae gastricae instead of the overlying thick mucus. However, acetylcysteine failed to improve either visualization of the areae gastricae or the general quality of the double contrast barium meal. (orig.)

  18. Comparison of three contrast radiographic techniques in the dog large intestine; Comparacion de tres tecnicas radiograficas de contraste en el intestino grueso del perro

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, L.; Thibaut, J.; Olhaberry, E.; Born, R.; Deppe, R. [Universidad Austral de Chile, Valdivia (Chile)

    1994-07-01

    In order to compare three radiographic techniques -pneumocolon, barium enema and double contrast- in the large intestine of the dog, three radiographic series in ventrodorsal and right lateral projections were taken. Six healthy adult dogs of both sexes with an approximate weight between 5 to 10 kg were used. Three enemas were administered 24, 12 and 2 hrs. before the series of radiographs were taken. Then dogs were anaesthetized with sodium tiopental (20 mg/kg iv) and the contrast media were introduced. Pneumocolon was carried out in the first series introducing air (20 cc/kg) in the large intestine through a Foley rectal catheter. Radiographs were taken in both projections, after 5 and 15min. respectively. Barium enema was performed in the second series introducing barium sulfate (18%) in the large intestine through a Foley rectal catheter (25 cc/kg); 5 and 15 min. later, the radiographs were taken. In the third series -double contrast- the barium sulfate, which was obtained from each dog using a catheter, was substituted by a volume of air equal to that obtained from the contrast medium. Later the radiographs were taken in both projections. The radiographic plates of each series were analized comparing the characteristics of: radiographic density, outline and volume. With the pneumocolon barium enema and double contrast, the radiographic density was, in most cases, low, high and inter-mediate respectively. The radiographic outline was, in most cases, regular for the three techniques. Thee radiographic volume was similar in all of the series. From the results obtained, it is concluded that double contrast best outlines the intestinal mucosa and more information can be obtained from it [Spanish] Con la finalidad de comparar tres tecnicas radiograficas del intestino grueso del perro -neumocolon, enema baritado y doble contraste-, se tomaron tres series radiograficas en proyeccion ventrodorsal y lateral derecha en 6 perros adultos, de 5 a 10 kg de peso, que

  19. Design of a multicentre randomized trial to evaluate CT colonography versus colonoscopy or barium enema for diagnosis of colonic cancer in older symptomatic patients: The SIGGAR study

    Directory of Open Access Journals (Sweden)

    Edwards Rob

    2007-10-01

    Full Text Available Abstract Background and Aims The standard whole-colon tests used to investigate patients with symptoms of colorectal cancer are barium enema and colonoscopy. Colonoscopy is the reference test but is technically difficult, resource intensive, and associated with adverse events, especially in the elderly. Barium enema is safer but has reduced sensitivity for cancer. CT colonography ("virtual colonoscopy" is a newer alternative that may combine high sensitivity for cancer with safety and patient acceptability. The SIGGAR trial aims to determine the diagnostic efficacy, acceptability, and economic costs associated with this new technology. Methods The SIGGAR trial is a multi-centre randomised comparison of CT colonography versus standard investigation (barium enema or colonoscopy, the latter determined by individual clinician preference. Diagnostic efficacy for colorectal cancer and colonic polyps measuring 1 cm or larger will be determined, as will the physical and psychological morbidity associated with each diagnostic test, the latter via questionnaires developed from qualitative interviews. The economic costs of making or excluding a diagnosis will be determined for each diagnostic test and information from the trial and other data from the literature will be used to populate models framed to summarise the health effects and costs of alternative approaches to detection of significant colonic neoplasia in patients of different ages, prior risks and preferences. This analysis will focus particularly on the frequency, clinical relevance, costs, and psychological and physical morbidity associated with detection of extracolonic lesions by CT colonography. Results Recruitment commenced in March 2004 and at the time of writing (July 2007 5025 patients have been randomised. A lower than expected prevalence of end-points in the barium enema sub-trial has caused an increase in sample size. In addition to the study protocol, we describe our approach to

  20. Air (CO2) double-contrast barium enteroclysis.

    Science.gov (United States)

    Maglinte, Dean D T; Kohli, Marc D; Romano, Stefania; Lappas, John C

    2009-09-01

    In the 1980s and 1990s in North America and Europe, air (CO(2)) double-contrast barium enteroclysis took a back seat to biphasic methylcellulose double-contrast enteroclysis in the investigation of small-bowel diseases. The widespread application of capsule endoscopy in the 21st century has identified a number of limitations of radiologic examinations in the investigation of mucosal diseases of the small intestine. Evidence-based studies comparing barium, computed tomographic (CT), and magnetic resonance (MR) enteroclysis have shown that in spite of improvements in small-bowel examination methods using CT and MR, barium examinations remain superior in the depiction of mucosal abnormalities, particularly the apthoid lesions of early Crohn disease. Barium small-bowel examinations have been recommended in the patient with a negative CT or MR enteroclysis study where the pretest probability of Crohn disease is high. A recent prospective comparison of methylcellulose double-contrast barium enteroclysis to capsule endoscopy with review of the literature has shown that air enteroclysis depicts mucosal details better than does methylcellulose double-contrast enteroclysis because of the "washout" effect of methylcellulose on superficial mucosal features. Recent articles have shown that air enteroclysis compares favorably with wireless capsule endoscopy and double-balloon endoscopy in the diagnosis of mucosal abnormalities of the small bowel. This article describes the authors' technique of performing air double-contrast enteroclysis, its clinical indications, and its pitfalls.

  1. Valor do enema de bário com duplo contraste no diagnóstico da endometriose do reto e sigmóide Double-contrast barium enema in the diagnosis of intestinal deeply infiltrating endometriosis

    Directory of Open Access Journals (Sweden)

    Helizabet Salomão Abdalla Ayroza Ribeiro

    2008-08-01

    Full Text Available OBJETIVO: avaliar a sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo do enema de bário com duplo contraste (EBDC para o diagnóstico da endometriose do reto e sigmóide. MÉTODOS: estudo transversal prospectivo que incluiu 37 pacientes com quadro clínico suspeito de endometriose profunda. As pacientes foram submetidas ao EBDC de acordo com a técnica padrão descrita na literatura. Em seguida, foram submetidas à laparoscopia. Os exames foram realizados e seus resultados e imagens foram interpretados e comparados com base na avaliação histológica. A análise estatística foi realizada pela análise de associação (teste do χ2 e análise de concordância (teste de Kappa. RESULTADOS: a média de idade das pacientes estudadas foi de 35,8±4,4 anos (faixa de 28 a 48 anos, sendo 85,6% brancas e 14,4% negras. A endometriose profunda foi confirmada por laparoscopia e pelo exame histológico em todas as pacientes estudadas. A endometriose intestinal foi confirmada histologicamente em 27 mulheres (72,9%. O EBDC demonstrou sinais radiológicos sugestivos de infiltração intestinal por endometriose em 24 mulheres (64,9% e ausência de sinais em 13 mulheres (35,1%. A sensibilidade do método foi de 87,5%, especificidade de 53,8%, valor preditivo positivo de 77,8% e valor preditivo negativo de 70%. Dentre os 24 exames anormais, 16 (43,2% apresentaram imagem radiológica do tipo espícula, 16 (43,2% apresentavam imagem compatível com estenose e quatro (10,8% o duplo contorno. CONCLUSÕES: o EBDC apresenta elevada sensibilidade e elevado valor preditivo positivo no diagnóstico da endometriose do reto e sigmóide. As imagens radiológicas do tipo espícula e estenose apresentam elevada sensibilidade e valor preditivo positivo para a infiltração intestinal por endometriose.PURPOSE: to evaluate the sensitivity, specificity, positive and negative predictive value of double contrast barium enema (DCBE for the diagnoses

  2. Contrast enema depiction of small-bowel volvulus in complicated neonatal bowel obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, Oscar M.; Daneman, Alan; Miller, Stephen F. [Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, ON (Canada)

    2004-12-01

    About one-half of patients with meconium ileus (MI) present with a complication such as volvulus, atresia, meconium peritonitis or giant cystic meconium peritonitis. The treatment of these complications requires surgery. However, the preoperative diagnosis of complicated MI is difficult. We describe two neonates with complicated small-bowel obstruction, one with MI related to cystic fibrosis and the other not related to cystic fibrosis. In both, contrast enema depicted a spiral appearance of the distal small bowel, which at surgery proved to be the result of volvulus associated with antenatal bowel perforation. This appearance of the small bowel on contrast enema in this clinical setting has not been previously described. The recognition of this spiral appearance of the distal small bowel suggests the need for surgery. (orig.)

  3. Contrast enema depiction of small-bowel volvulus in complicated neonatal bowel obstruction

    International Nuclear Information System (INIS)

    Navarro, Oscar M.; Daneman, Alan; Miller, Stephen F.

    2004-01-01

    About one-half of patients with meconium ileus (MI) present with a complication such as volvulus, atresia, meconium peritonitis or giant cystic meconium peritonitis. The treatment of these complications requires surgery. However, the preoperative diagnosis of complicated MI is difficult. We describe two neonates with complicated small-bowel obstruction, one with MI related to cystic fibrosis and the other not related to cystic fibrosis. In both, contrast enema depicted a spiral appearance of the distal small bowel, which at surgery proved to be the result of volvulus associated with antenatal bowel perforation. This appearance of the small bowel on contrast enema in this clinical setting has not been previously described. The recognition of this spiral appearance of the distal small bowel suggests the need for surgery. (orig.)

  4. Complications encountered in contrast roentgenography of the colon

    International Nuclear Information System (INIS)

    Vogel, H.; Steinkamp, U.

    1983-01-01

    The following problems are analysed referring to the literature and to practical experience of the authors: - Types of complications encountered in contrast roentgenography or in endoscopy of the colon, and their frequency. - Risk factors and secondary injuries. Intestinal perforation is the most frequent complication experienced as a consequence of contrast barium enema. The main risk factors are to be seen in the use of balloon-tipped catheters, or of intestinal tubes with hard tips, in a rise of hydrostatic pressure above 80 cm water column, and in an excessively strong air insufflation. Frequency of complications for contrast barium enema is stated to be 0.002 p.c. (Welin and Welin, 1980) or 0.08 p.c. (Clark et al. 1961). The frequency of perforations in rectoscopy is shown to be in the same order of magnitude. For diagnostic colonoscopy, the frequency of complications is about one per mil. Existing diseases such as carcinoma, diverticulosis, diverticulitis, colitis ulcerosa, or morbus Crohn are factors enhancing the risk. Also, patients of advanced age are running a higher risk due to decreasing intestine wall elasticity with age. Previous biopsy or excision forbids contrast barium enema for the next two weeks. Injuries and sequelae to be expected after perforation are abscesses, phlegmon, peritonitis including formation of adhesion and bands, retroperitoneal fibrosis with formation of hydronephrosis, and anus praeter, the latter being temporary or permanent. An extensive literature survey covering 200 publications has been prepared and is available from the authors upon request. (orig.) [de

  5. An assessment of the accuracy of contrast enema for the diagnosis ...

    African Journals Online (AJOL)

    Diagnostic accuracy levels were calculated by comparing radiological results with histology results, which is the gold standard. Results: Diagnostic accuracy of contrast enema was 78%, sensitivity was 94.4% and the negative predictive value was 95.7%. Specificity (68.8%) and positive predictive values (63%) were ...

  6. Contrast characteristics of barium preparations and the timing of exposure

    OpenAIRE

    渋谷, 光一; 中桐, 義忠; 東, 義晴; 杉田, 勝彦; 小橋, 高郎; 大倉, 保彦; 丹谷, 延義; 三上, 泰隆; 平木, 祥夫

    1995-01-01

    We studied the relationship between the contrast characteristics of barium suspension and timing of exposure. We poured several kinds of barium preparations on the phantom manufactured by ourselves, and took X-ray pictures continuously by a DSA system. We analyzed each of the characteris-tics of the contrast. The time which was reguired for the contrast to reach the peak (Contrast Peak Time ; CPT) was unrelated with the kind of barium preparations used. It depended on the viscosity of the con...

  7. The novel appearance of low rectal anastomosis on contrast enema following laparoscopic anterior resection: discriminating anastomotic leaks from "dog-ears" on water-soluble contrast enema and flexible sigmoidoscopy.

    Science.gov (United States)

    Katory, Mark; McLean, Ross; Osman, Khalid; Ahmad, Mukhtar; Hughes, Tracey; Newby, Mike; Dennison, Christopher; O'Loughlin, Paul

    2017-02-01

    Interpretation of water-soluble contrast enema following laparoscopic low anterior resection can be very challenging for both radiologists and colorectal surgeons. Discriminating the radiological appearances secondary to anastomotic configuration from those caused by actual anastomotic dehiscence is a common problem and may be made worse with the advent of laparoscopic surgery. The aim of this study is to identify potential novel appearances of the water-soluble contrast enema (WSCE) images of rectal anastomosis following laparoscopic low anterior resection to radiologists and surgeons. We enrolled 45 patients who underwent laparoscopic low anterior resection with proximal de-functioning loop ileostomy within a specialized colorectal unit. The water-soluble contrast enema reports were reviewed. Two blinded colorectal radiologists independently reviewed the images of patients suspected of anastomotic leak. All of these patients also underwent a flexible sigmoidoscopy to confirm or exclude anastomotic leak before reversal of loop ileostomy. Inter-observer concordance was calculated. Seven out of eighteen patients (38.9%) were found to have true anastomotic leaks on flexible sigmoidoscopy (15% overall leak rate). In the remaining eleven patients the image appearances were attributed to the appearance of the anastomotic 'dog-ear effect', created by the anastomotic configuration due to multiple firing of the intra-corporeal laparoscopic stapling device. Radiologist inter-observer concordance was 83%. Sensitivity was 100%, specificity 71%, positive-predictive value (38.9%) and negative-predictive value (100%). The novel appearances of laparoscopic-stapled rectal anastomoses in WSCE can be mistaken for anastomotic leak. To avoid delay in reversal of ileostomy, a flexible sigmoidoscopy can be used to confirm or exclude a leak.

  8. Effect of sodium bicarbonate pretreatment on barium coating of mucosa during double contrast barium meal

    International Nuclear Information System (INIS)

    Kinnunen, J.; Toetterman, S.; Kaila, R.; Pietilae, J.; Linden, H.; Tervahartiala, P.

    1983-01-01

    The radiographic pattern of the areae gastricae is produced by barium lying in the intersecting furrows of the gastric mucosal surface. However, if the mucus layer on the gastric mucosa is thick, it interferes with the barium coating of the areae gastricae during double contrast barium meal. As sodium bicarbonate decreases the viscosity of mucus and thus may make the gastric mucus layer thinner, it was evaluated as a pretreatment agent in a routine double contrast upper-gastrointestinal study to improve the visualization of the areae gastricae. In a single blind study, 53 of 106 patients took sodium bicarbonate water mixtures at bedtime the day before and on the morning of the examination. According to the results of the present study mucolysis induced by the used doses of sodium bicarbonate does not significantly affect micromucosal visualization during double-contrast barium meal. (orig.) [de

  9. Effect of sodium bicarbonate pretreatment on barium coating of mucosa during double contrast barium meal

    Energy Technology Data Exchange (ETDEWEB)

    Kinnunen, J.; Toetterman, S.; Kaila, R.; Pietilae, J.; Linden, H.; Tervahartiala, P.

    1983-08-01

    The radiographic pattern of the areae gastricae is produced by barium lying in the intersecting furrows of the gastric mucosal surface. However, if the mucus layer on the gastric mucosa is thick, it interferes with the barium coating of the areae gastricae during double contrast barium meal. As sodium bicarbonate decreases the viscosity of mucus and thus may make the gastric mucus layer thinner, it was evaluated as a pretreatment agent in a routine double contrast upper-gastrointestinal study to improve the visualization of the areae gastricae. In a single blind study, 53 of 106 patients took sodium bicarbonate water mixtures at bedtime the day before and on the morning of the examination. According to the results of the present study mucolysis induced by the used doses of sodium bicarbonate does not significantly affect micromucosal visualization during double-contrast barium meal.

  10. A modified per os double contrast examination of the colon in the elderly

    International Nuclear Information System (INIS)

    Papadaki, P.J.; Vassiliou, P.M.; Zavras, G.M.; Kounis, N.G.; Hadjioannou, N.; Fezoulidis, I.B.; Manolakis, P.; Kelekis, D.

    1993-01-01

    A modified per os double contrast examination of the colon was used in 62 elderly patients in whom conventional barium enema had been unsuccessful. We created endogenous gas generation instead of air insufflation by per os administration of a special mixture containing barium sulftate, lactulose and gastrographin. Good quality double contrast images of the colon were obtained after 12 hours in 59 of the 62 patients. The sensitivity of the method was 100% in 6 patients suffering from carcinoma and in 15 patients suffering from diverticular disease. However, the method failed to demonstrate small solitary polyps in 5 patients and it was also negative in another 27 patients. 7 of these had negative endoscopy and in the remaining a definite diagnosis was not established by any other method. It seems that this method may become an alternative for investigation of suspected colonic pathology in the elderly patients with difficulty in retaining the barium enema. (orig.) [de

  11. A modified per os double contrast examination of the colon in the elderly

    Energy Technology Data Exchange (ETDEWEB)

    Papadaki, P J [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Vassiliou, P M [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Zavras, G M [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Kounis, N G [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Hadjioannou, N [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Fezoulidis, I B [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patras (Greece); Manolakis, P [Radiology Department, NIMTS General Hospital, Athens, and Radiology Department, Medical School, University of Patra

    1993-04-01

    A modified per os double contrast examination of the colon was used in 62 elderly patients in whom conventional barium enema had been unsuccessful. We created endogenous gas generation instead of air insufflation by per os administration of a special mixture containing barium sulftate, lactulose and gastrographin. Good quality double contrast images of the colon were obtained after 12 hours in 59 of the 62 patients. The sensitivity of the method was 100% in 6 patients suffering from carcinoma and in 15 patients suffering from diverticular disease. However, the method failed to demonstrate small solitary polyps in 5 patients and it was also negative in another 27 patients. 7 of these had negative endoscopy and in the remaining a definite diagnosis was not established by any other method. It seems that this method may become an alternative for investigation of suspected colonic pathology in the elderly patients with difficulty in retaining the barium enema. (orig.)

  12. BARIUM REDUCTION OF INTUSSUSCEPTION IN INFANCY

    Science.gov (United States)

    Denenholz, Edward J.; Feher, George. S.

    1955-01-01

    Barium enema reduction was used as the initial routine treatment in 29 infants with intussusception. In 22 of them the intussusception was reduced by this means. In three of eight patients operated upon the intussusception was found to be reduced. Four of the remaining five patients had clinical or x-ray evidence of complications before reduction by barium enema was attempted. Twenty-one of the patients, all of whom were observed in private practice, were treated without admission to the hospital. After reduction, these patients were observed closely by the clinician. None of these patients showed clinical or x-ray signs of complications before reduction. Certain clinical and roentgen criteria must be satisfied before it can be concluded that reduction by barium enema is complete. If there are clinical signs of complications with x-ray evidence of small bowel obstruction, only a very cautious attempt at hydrostatic reduction should be made. As the time factor is generally a reliable clinical guide to reducibility, the late cases should be viewed with greater caution. Long duration of symptoms, however, is not per se a contraindication to an attempt at hydrostatic reduction. PMID:13230908

  13. Patient acceptability of CT colonography compared with double contrast barium enema: results from a multicentre randomised controlled trial of symptomatic patients

    International Nuclear Information System (INIS)

    Wagner, Christian von; Smith, Samuel; Ghanouni, Alex; Power, Emily; Wardle, Jane; Halligan, Steve; Lilford, Richard J.; Morton, Dion; Dadswell, Edward; Atkin, Wendy

    2011-01-01

    To determine patient acceptability of barium enema (BE) or CT colonography (CTC). After ethical approval, 921 consenting patients with symptoms suggestive of colorectal cancer who had been randomly assigned and completed either BE (N = 606) or CTC (N = 315) received a questionnaire to assess experience of the clinical episode including bowel preparation, procedure and complications. Satisfaction, worry and physical discomfort were assessed using an adapted version of a validated acceptability scale. Non-parametric methods assessed differences between the randomised tests and the effect of patient characteristics. Patients undergoing BE were significantly less satisfied (median 61, interquartile range [IQR] 54-67 vs. median 64, IQR 56-69; p = 0.003) and experienced more physical discomfort (median 40, IQR 29-52 vs. median 35.5, IQR 25-47; p < 0.001) than those undergoing CTC. Post-test, BE patients were significantly more likely to experience 'abdominal pain/cramps' (68% vs. 57%; p = 0.007), 'soreness' (57% vs. 37%; p < 0.001), 'nausea/vomiting' (16% vs. 8%; p = 0.009), 'soiling' (31% vs. 23%; p = 0.034) and 'wind' (92% vs. 84%; p = 0.001) and in the case of 'wind' to also rate it as severe (27% vs. 15%; p < 0.001). CTC is associated with significant improvements in patient experience. These data support the case for CTC to replace BE. (orig.)

  14. Patient acceptability of CT colonography compared with double contrast barium enema: results from a multicentre randomised controlled trial of symptomatic patients.

    Science.gov (United States)

    von Wagner, Christian; Smith, Samuel; Halligan, Steve; Ghanouni, Alex; Power, Emily; Lilford, Richard J; Morton, Dion; Dadswell, Edward; Atkin, Wendy; Wardle, Jane

    2011-10-01

    To determine patient acceptability of barium enema (BE) or CT colonography (CTC). After ethical approval, 921 consenting patients with symptoms suggestive of colorectal cancer who had been randomly assigned and completed either BE (N = 606) or CTC (N = 315) received a questionnaire to assess experience of the clinical episode including bowel preparation, procedure and complications. Satisfaction, worry and physical discomfort were assessed using an adapted version of a validated acceptability scale. Non-parametric methods assessed differences between the randomised tests and the effect of patient characteristics. Patients undergoing BE were significantly less satisfied (median 61, interquartile range [IQR] 54-67 vs. median 64, IQR 56-69; p = 0.003) and experienced more physical discomfort (median 40, IQR 29-52 vs. median 35.5, IQR 25-47; p < 0.001) than those undergoing CTC. Post-test, BE patients were significantly more likely to experience 'abdominal pain/cramps' (68% vs. 57%; p = 0.007), 'soreness' (57% vs. 37%; p < 0.001), 'nausea/vomiting' (16% vs. 8%; p = 0.009), 'soiling' (31% vs. 23%; p = 0.034) and 'wind' (92% vs. 84%; p = 0.001) and in the case of 'wind' to also rate it as severe (27% vs. 15%; p < 0.001). CTC is associated with significant improvements in patient experience. These data support the case for CTC to replace BE.

  15. Barium sulfate suspension as a negative oral contrast agent for MR imaging

    International Nuclear Information System (INIS)

    Li, K.C.P.; Tart, R.P.; Fitzsimmons, J.R.; Storm, B.; Mao, J.

    1989-01-01

    Proton spectroscopy with linewidth measurements and MR imaging were performed on various commercially available barium sulfate suspensions as well as inorganic sulfates and barium salts. Approximately 500 mL of 20%, 40%, 60%, and 70% wt/wt single-contrast oral barium sulfate suspensions were administered to four normal volunteers, and MR imaging was performed with both a 1.5-T and a 0.15-T MR imager. As much as 80% of the small bowel and the entire colon were well visualized with the 60% or 70% wt/wt single-contrast barium sulfate suspensions. The authors conclude that barium sulfate suspensions are useful as oral MR contrast agents

  16. Patient acceptability of CT colonography compared with double contrast barium enema: results from a multicentre randomised controlled trial of symptomatic patients

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Christian von; Smith, Samuel; Ghanouni, Alex; Power, Emily; Wardle, Jane [University College London, Department of Epidemiology and Public Health, London (United Kingdom); Halligan, Steve [University College London, Centre for Medical Imaging, London (United Kingdom); University College Hospital, Centre for Medical Imaging, London (United Kingdom); Lilford, Richard J. [Birmingham University, Department of Epidemiology, Birmingham (United Kingdom); Morton, Dion [Birmingham University, Department of Surgery, Birmingham (United Kingdom); Dadswell, Edward; Atkin, Wendy [Imperial College London, Department of Surgery and Cancer, London (United Kingdom)

    2011-10-15

    To determine patient acceptability of barium enema (BE) or CT colonography (CTC). After ethical approval, 921 consenting patients with symptoms suggestive of colorectal cancer who had been randomly assigned and completed either BE (N = 606) or CTC (N = 315) received a questionnaire to assess experience of the clinical episode including bowel preparation, procedure and complications. Satisfaction, worry and physical discomfort were assessed using an adapted version of a validated acceptability scale. Non-parametric methods assessed differences between the randomised tests and the effect of patient characteristics. Patients undergoing BE were significantly less satisfied (median 61, interquartile range [IQR] 54-67 vs. median 64, IQR 56-69; p = 0.003) and experienced more physical discomfort (median 40, IQR 29-52 vs. median 35.5, IQR 25-47; p < 0.001) than those undergoing CTC. Post-test, BE patients were significantly more likely to experience 'abdominal pain/cramps' (68% vs. 57%; p = 0.007), 'soreness' (57% vs. 37%; p < 0.001), 'nausea/vomiting' (16% vs. 8%; p = 0.009), 'soiling' (31% vs. 23%; p = 0.034) and 'wind' (92% vs. 84%; p = 0.001) and in the case of 'wind' to also rate it as severe (27% vs. 15%; p < 0.001). CTC is associated with significant improvements in patient experience. These data support the case for CTC to replace BE. (orig.)

  17. Aspiration of barium contrast medium in an elderly man with disordered swallowing

    OpenAIRE

    Bağcı Ceyhan, B.; Çelikel, T.; Koç, M.; Ahıskalı, R.; Biren, T.; Ataizi Çelikel, Ç.

    1995-01-01

    The aspiration of contrast medium during the investigation of gastrointestinal diseases is a well recognized hazard, particularly in patients with swallowing disorders. A case is reported in which accidental aspiration of contrast barium occurred owing to disordered swallowing in an elderly man. The infiltration on chest x-ray persisted 2 years after barium contrast aspiration. Inflammatory reaction and retractile, granular material observed in lung biopsy specimens suggested barium-induced p...

  18. On film quality in barium-air double contrast colon study

    International Nuclear Information System (INIS)

    Rhu, Sang Hyung; Rhee, Jae Ho; Kim, Hai Sung; Cheung, Hwan

    1984-01-01

    The colon double contrast study provides valuable diagnostic information by means of appropriate control of Kvp and mAa when making double contrast image by injecting air into the colon after coating the colon wall by appropriately diluted Barium solution. The following experiments were performed the results of which allowed to improve the quality of film in barium-air double contrast colon study: (1) Do the pictures have uniform density when measured with a densitometer from three measuring points established in the picture by changing Kvp and mAs depending on the thickness of the patient? (2) Is the quality of the picture improved by being compensated from the adjacent area when using a wedge filter in routine check lateral decubitus and erect view? (3) What is the optimum dilution of barium solution which gives the best result for colon wall coating? The above experiments revealed that as the patient's thickness increased, it should be considered to increase mAs as well as Kvp and a wedge filter could give diagnostically very informative pictures in routine-check lateral decubitus and erect view. And 70-80% solution of Barium-water mixture provided the best quality of double contrast image

  19. Contrast enema findings in patients presenting with poor functional outcome after primary repair for Hirschsprung disease.

    Science.gov (United States)

    Garrett, Kevin M; Levitt, Marc A; Peña, Alberto; Kraus, Steven J

    2012-09-01

    The radiologic evaluation of Hirschsprung disease is well described in the literature. However, there is a paucity of literature describing the appearance of the neo-rectum and colon after repair, specifically describing findings in patients with poor functional outcome, which would suggest the need for reoperation. We describe findings on contrast enema and correlate them with surgical findings at reoperation in children with poor functional outcome after primary repair for Hirschsprung disease who suffer from bowel dysfunction that can manifest with either soiling or obstructive symptoms such as enterocolitis. Children were identified from our colorectal surgery database. At the time of abstract submission, 35 children had contrast enemas prior to reoperation. Additional children continue to present for evaluation. The majority of children included in the study had their primary repair performed elsewhere. The initial procedures included: Duhamel (n = 11), Soave (n = 20) or Swenson (n = 3). One child had undergone a primary Soave repair and subsequently had a Swenson-type reoperation but continued to have a poor outcome. One child's initial surgical repair could not be determined. Images were reviewed by a staff pediatric radiologist and a pediatric radiology fellow. Findings encountered on contrast enema in these children include a distal narrowed segment due to stricture or aganglionic/transitional zone segment (8), dilated/hypomotile distal segment (7), thickened presacral space due to compressing Soave cuff (11), dilated Duhamel pouch (8), active enterocolitis (3) and partially obstructing twist of the pull-through segment (1). Multiple anatomical and pathological complications exist that can lead to bowel dysfunction in children after repair of Hirschsprung disease. Little recent literature exists regarding the radiographic findings in children. We had the opportunity to review a substantial series of these children, describe the contrast enema

  20. Carcinoma of the colon: Diagnosis by ultrasound and enema

    International Nuclear Information System (INIS)

    Cremin, B.J.; Brown, R.A.

    1987-01-01

    Carcinoma of the colon presenting before puberty is rare and few cases have been recorded in radiological literature. The symptomatology is usually vague but may be similar to the classical presentation of adults. The barium enema will also show the same constricting lesions. Two cases are reported, in one of which the initial diagnosis was made by ultrasound. (orig.)

  1. Carcinoma of the colon: Diagnosis by ultrasound and enema

    Energy Technology Data Exchange (ETDEWEB)

    Cremin, B.J.; Brown, R.A.

    1987-05-01

    Carcinoma of the colon presenting before puberty is rare and few cases have been recorded in radiological literature. The symptomatology is usually vague but may be similar to the classical presentation of adults. The barium enema will also show the same constricting lesions. Two cases are reported, in one of which the initial diagnosis was made by ultrasound.

  2. Radiologic diagnosis of gastro-oesophageal reflux. Comparison of barium and low-density contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, S.G.; Soekjer, H.; Johansson, K.E.; Tibbling, L.

    It has been proposed that the high density of ordinary barium suspension may complicate the radiologic diagnosis of gastro-oesophageal reflux. For this reason P-contrast was developed (Ferring AB); a contrast medium with the same density as water (1 g/cm/sup 3/). A comparison of P-contrast and barium (Mixobar Ventrikel 400 mg/ml) was performed in 82 patients. All patients were examined with both contrast media and the findings were compared with those at reflux test at manometry, endoscopy and 24-hour pH monitoring. Another 40 patients and 15 symptom-free controls were examined with two different amounts of barium, 100 ml and 200 ml, to study if the radiologic diagnosis of reflux varied with the volume of contrast medium administered. P-contrast was found to have no advantages over barium for the diagnosis of gastro-oesophageal reflux. The outcome of the radiologic examination was not influenced by the different volumes of barium used.

  3. A double-blind randomised, placebo-controlled trial evaluating the influence of oral long-acting muscle relaxant (Mebeverine MR), and insufflation with CO{sub 2} on pain associated with barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, A.S.; Chapman, A.H.; Wilson, D.; Culpan, A.G. [Department of Radiology, St. James' s University Hospital, Beckett Street, LS9 7TF, Leeds (United Kingdom)

    2003-07-01

    Previous investigators have shown significant benefit using CO{sub 2} for bowel insufflation. Others have suggested that the long-acting smooth muscle relaxant, Mebeverine, may be of benefit. We subjected this to a randomised double-blind trial. A total of 181 outpatients were randomised to receive either Mebeverine or placebo as pre-medication, and either air or CO{sub 2} for bowel insufflation, thus creating four treatment groups. Visual-analogue lines were used to record pain scores before, during, and up to 8 h following the enema. All groups showed increased pain scores during the enema, with peak pain scores at the end of the examination, falling to baseline scores by 8 h. Patients receiving the combination of C0{sub 2} and placebo had significantly lower pain scores at 1 and 4 h (P=0.00 and P=0.014, respectively; Kruskal-Wallis test) compared with all other groups. Having Mebeverine as a pre-medication did not significantly lower pain scores compared with placebo, and decreased the amount of benefit received from the CO{sub 2}. We confirm that CO{sub 2} is of benefit in decreasing pain during barium enema, and we recommend its routine use to improve the comfort of patients. Mebeverine is not of benefit, and its use as a pre-medication for enemas is not recommended. (orig.)

  4. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.

    Science.gov (United States)

    Anderson, N G; Butler, A P; Scott, N J A; Cook, N J; Butzer, J S; Schleich, N; Firsching, M; Grasset, R; de Ruiter, N; Campbell, M; Butler, P H

    2010-09-01

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 microA). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications.

  5. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, N.G. [University of Otago, Department of Radiology, Christchurch (New Zealand); Butler, A.P. [University of Otago, Department of Radiology, Christchurch (New Zealand); University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Scott, N.J.A. [University of Otago, Department of Medicine, Christchurch (New Zealand); Cook, N.J. [Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Butzer, J.S. [Karlsruhe Institute of Technology, Physics Department, Karlsruhe (Germany); Schleich, N. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Firsching, M. [Friedrich Alexander University, Physics Department, Erlangen (Germany); Grasset, R.; Ruiter, N. de [University of Canterbury, Hitlab NZ, Christchurch (New Zealand); Campbell, M. [European Organisation for Nuclear Research, Physics Section, Geneva (Switzerland); Butler, P.H. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand)

    2010-09-15

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 {mu}A). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at <55 {mu}m isotropic voxels. Spectral CT distinguishes contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications. (orig.)

  6. [Value of preoperative barium contrast examination for the diagnosis and operative planning in gastric cancer].

    Science.gov (United States)

    Wang, Chang-jian; Zhao, Guang-fa; Li, Qing-guo; Chen, Jing-gui; Zhu, Kai; Shi, Ying-qiang; Fu, Hong

    2010-04-01

    To investigate the value of preoperative barium contrast examination for the diagnosis and operative planning in gastric cancer. Clinical data of 229 gastric cancer patients were analyzed retrospectively. Lesions were divided into three parts: the cardiac, the body, and the antrum. The diagnostic accuracy of localization and the extent of tumor between gastroscopy alone and gastroscopy plus barium contrast were compared with the results of surgical findings. The diagnostic accuracy of localization and the extent of tumor for gastroscopy in the cardiac, the body and the antrum cancers were 100% and 78.4%, 94.6% and 86.5%, 98.1% and 84.6%, respectively, while for gastroscopy plus barium contrast were 100% and 84.8%, 100% and 91.9%, 99.0% and 90.4%, respectively. The diagnostic accuracy of both the localization and the extent of tumor were not significantly different between gastroscopy alone and gastroscopy plus barium contrast (P>0.05). Diagnostic accuracy of the length of esophagus infiltrated by cardiac cancer in gastroscopy was 60.6%, while in gastroscopy plus barium contrast was 90.9%, which was significantly different (Pbarium contrast was more accurate in predicting the possibility of thoracotomy in cardiac cancer infiltrating the lower esophagus. It is necessary to perform preoperative barium contrast examination in cardiac cancer patients, so as to identify whether the lower esophagus is infiltrated and to measure the length of lesion, which can provide evidences for making a decision of thoracotomy. For gastric body and antrum cancer, there is no indication for barium contrast examination if gastroscopy findings are satisfied.

  7. [Comparison of iodinated and barium-containing contrast media of different viscosity in the detection of pharyngeal perforation].

    Science.gov (United States)

    Keberle, M; Wittenberg, G; Trusen, A; Baumgartner, W; Hahn, D

    2001-08-01

    In contrast to esophageal perforations, the more radiopaque barium-suspensions are not as important as iodinated aqueous contrast agents for the detection of pharyngeal perforations. This study was performed to find out whether the highly different viscosities (of iodinated and barium-containing contrast agents with comparable radiopacities) are a reason for this. Viscosity, subjective difference in contrast, and CT-density of an iodinated aqueous (Telebrix) and a 50 wt/vol% barium-containing contrast agent (Micropaque) were determined. Moreover, to exclude postoperative perforation, 104 patients were prospectively examined by pharyngography using both contrast media. Pharyngographies of patients with perforation were later compared by two independent readers. All patients with perforation were followed up clinically to exclude complications due to barium administration. In-vitro comparison showed comparable radiopacity but the 50 wt/vol% barium-suspension was much more viscous than the iodinated contrast agent. During pharyngography, totally, 14 perforations were clearly delineated with the iodinated aqueous contrast agent. However, two of them were not detected with the barium-suspension. All the other perforations presented equally. Given a sufficient radiopacity, a low viscosity appears to be essential for a contrast agent to detect especially pharyngeal perforations. Thus, we recommend the sole use of an iodinated contrast agent (at suspicion of aspiration as isoosmolar variant) for this purpose.

  8. Water-soluble contrast media compared with barium in enteric follow-through

    International Nuclear Information System (INIS)

    Laerum, F.; Stordahl, A.; Aase, S.

    1988-01-01

    The local effects and radiographic efficacy of 4 water-soluble contrast media, barium and saline were evaluated in 86 anaesthetized rats with the distal ileum ligated. The rats were observed for 8 hours after instillation of 3 ml of the test substance via orogastric tube. Radiographs were taken after 1, 4 and 8 hours of observation. After 8 hours the intestines were weighed and biopsied for light microscopy, and blood and urine were sampled for testing. Sodium diatrizoate caused increased fluid influx to the bowel lumen and, like barium, provided poorer radiographic images as compared with iohexol, ioxaglate or iodixanol. Barium showed slower progression through the small bowel than the other agents, while sodium diatrizoate was the most rapidly progressing contrast medium and caused the greatest distension. Correlation to osmolality was obvious. No significant morphologic effects on the small bowel mucosa were seen in any of the groups. Low-osmolar, water-soluble contrast media may have prospects for clinical use in patients with suspected small bowel obstruction. (orig.)

  9. Double contrast with technique of Insufflated Barium Meal in the radiological study of the esophagus

    International Nuclear Information System (INIS)

    Gallina, F.; Piga, V.; Gallina, M.S.

    1985-01-01

    The results are reported of the esophagus double contrast examination with Insufflated Barium Meal technique as first part of the routine upper digestive system radiological examination. This technique gives good double contrast without those artifacts using effervescent powders and without modifying the normal radiological alimentary tract examination established way. The double contrast is administered by a special container with a built-in mouthpiece which allows the simultaneous ingestion of barium suspension and air. The esophageal mucosa can be examined as far as the distal tract where frequently the barium contrast stops using different techniques. Good results in 90% of patients have been obtained. The early detection of inflammatory and tumoral lesions has taken particular advantage in patients sometimes asymptomatic

  10. Double contrast with technique of Insufflated Barium Meal in the radiological study of the esophagus

    Energy Technology Data Exchange (ETDEWEB)

    Gallina, F; Piga, V; Gallina, M.S. and others

    1985-01-01

    The results are reported of the esophagus double contrast examination with Insufflated Barium Meal technique as first part of the routine upper digestive system radiological examination. This technique gives good double contrast without those artifacts using effervescent powders and without modifying the normal radiological alimentary tract examination established way. The double contrast is administered by a special container with a built-in mouthpiece which allows the simultaneous ingestion of barium suspension and air. The esophageal mucosa can be examined as far as the distal tract where frequently the barium contrast stops using different techniques. Good results in 90% of patients have been obtained. The early detection of inflammatory and tumoral lesions has taken particular advantage in patients sometimes asymptomatic.

  11. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE

    CERN Document Server

    Anderson, NG; Firsching, M; de Ruiter, N; Schleich, N; Butzer, J S; Cook, N J; Grasset, R; Campbell, M; Scott, N J A; Anderson, N G

    2010-01-01

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 A mu A). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct f...

  12. Massive rectal bleeding from colonic diverticulosis

    African Journals Online (AJOL)

    ABEOLUGBENGAS

    barium enema studies have indicated increasing world prevalence ... Other diagnostic modalities include barium enema, computerised ... This is in contrast to the findings in our patient when colonoscopy was carried out, in which the diverticula were more at the descending colon-left sided, and were found to be bleeding.

  13. [Progress in the early diagnosis of cancer of the colon and rectum].

    Science.gov (United States)

    Canessa, N; Roset, J; Boffi, A; Ferrara, J B; Galano, A; Albertengo, J C

    1978-09-01

    Our experience with the air contrast examination in the cancer of colon and rectum diagnoses is showed. The colaboration among radiologist, endoscopist, pathologist and surgeon is important. In the large bowel tumors diagnosis, the radiologic and endoscopic prodedures should be evaluated together. The double colonic contrast has showed in our experience, better results than with the barium enema. Over 31 patients with both studies, we obtained 13 false negatives (with barium enema, doing then the double colonic contrast became positive 12 (92.4%).

  14. Radiation dose measurement in gastrointestinal studies

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Kappas, C.; Theodorou, K.

    2011-01-01

    Barium studies investigations (barium swallow, barium meal and barium enema) are the basic routine radiological examination, where barium sulphate suspension is introduced to enhance image contrast of gastrointestinal tracts. The aim of this study was to quantify the patients' radiation doses during barium studies and to estimate the organ equivalent dose and effective dose with those procedures. A total of 33 investigations of barium studies were measured by using thermoluminescence dosemeters. The result showed that the patient entrance surface doses were 12.6±10, 44.5±49 and 35.7±50 mGy for barium swallow, barium meal, follow through and enema, respectively. Effective doses were 0.2, 0.35 and 1.4 mSv per procedure for barium swallow, meal and enema respectively. Radiation doses were comparable with the previous studies. A written protocol for each procedure will reduce the inter-operator variations and will help to reduce unnecessary exposure. (authors)

  15. Figure 3a," 3b

    African Journals Online (AJOL)

    2005-06-28

    Jun 28, 2005 ... Barium enema may show the caecum in a normal position or it may be incompletely rotated. A Barium follow-thru enema may give the same findings. More recently CT scans without and then with contrast has been shown to be useful. All these investigations may be performed without any diagnostic yield ...

  16. Hereditary nonpolyposis colorectal cancer: not just a barium enema{exclamation_point} Radiographic manifestations and screening tools

    Energy Technology Data Exchange (ETDEWEB)

    Foster, L.; Jeon, P. [Health Sciences Center, Diagnostic Imaging, St. John' s, Newfoundland (Canada)]. E-mail: u43dlb@mun.ca; Green, J. [Health Sciences Center, Discipline of Genetics, Faculty of Medicine, St. John' s, Newfoundland (Canada)

    2007-10-15

    Hereditary nonpolyposis colorectal cancer (HNPCC) is an autosomal dominant trait characterized by presentation of colorectal cancer (CRC) at an early age and by an increased risk of other primary malignancies, including those of the endometrium. ovaries, stomach, small bowel, upper biliary tract, skin, and brain, as well as by transitional cell carcinoma (TCC) that especially involves the renal pelvis and ureter. Because specific genetic mutations causing HNPCC have been recently discovered, genetic screening options have been developed for some families. Subsequently, radiology has an increasing role in surveillance for and management of these HNPCC-associated tumours. Although colonoscopy is the mainstay of a screening regimen for colon cancer, the barium enema has been a standard radiologic investigation. Further, computed tomography (CT) colonography (now practised in various centres) will, with further refinement, prove to be of increasing value. Ultrasonography is a standard investigation for endometrial and ovarian cancer, with CT and magnetic resonance (MR) imaging often playing a central role. As for TCC, intravenous urography (IVU) had been a standard investigation tool. However, with continued evolution of multidetector row CT with postprocessing manipulation (CT urography [CTU]), the role of IVU is diminishing in most centres. Newfoundland has a high prevalence of HNPCC exhibiting a broad range of manifestations. In this article, radiologic images of various tumours from individuals with HNPCC demonstrate a radiologic spectrum of this fascinating hereditary disease. Screening implications and specific screening methods are reviewed. (author)

  17. The impact of digital imaging on patient doses during barium studies

    International Nuclear Information System (INIS)

    Broadhead, D.A.; Chapple, C.-L.; Faulkner, K.

    1995-01-01

    Barium studies performed on 10 digital and four non-digital fluoroscopic systems were monitored with dose-area product meters as part of a Regional Patient Dosimetry Audit programme. The data have been collected using a computer to read and reset the dose-area product meter and also to collect patient and examination details. A comparison of dose-area product measurements from digital and non-digital fluoroscopy units on over 10 000 barium studies is presented. The data have been corrected according to patient size. The mean size corrected dose-area product for a barium meal examination was found to be 7.62 Gy cm -2 for a digital set compared with 15.45 Gy cm -2 for a non-digital set with 2462 and 1308 patients included in each measurement series, respectively. Dose-area products were also a factor of approximately two lower for barium enema, barium swallow and barium follow-through examinations performed on digital systems. (author)

  18. Computed tomography of the colo-rectal cancer using the olive oil enema

    International Nuclear Information System (INIS)

    Katayama, Hiroshi; Hori, Shinichi; Ohkawa, Motoomi; Fujikawa, Koichi; Mori, Masaki; Katsuta, Shizutomo.

    1983-01-01

    The recent widespread use of the double contrast Ba enema method has allowed considerable progress to be made in the diagnosis of colo-rectal cancer. However, the double contrast Ba enema technique has been found to be inadequate in the detection of the extra-luminal extensions of cancer in its early stage. CT can be utilized as an accurate non-invasive technique for evaluating colon tumors, particularly in the rectum and sigmoid colon which are adjacent to many organs. It is possible to apply CT for evaluating whether the cancer's extra-luminal extensions are at a preoperative stage or not. Due to the many limitations inherent in the Ba enema study. We developed a new olive oil enema technique to make it possible to more accurately differentiate the intra-luminal lesion, the intestinal wall and the extra-luminal extension. (author)

  19. MR Colonography with fecal tagging: Barium vs. barium ferumoxsil

    DEFF Research Database (Denmark)

    Achiam, M.P.; Chabanova, E.; Logager, V.B.

    2008-01-01

    and Methods. Twenty patients referred to CC underwent dark lumen MRC prior to the colonoscopy. Two groups of patients received two different oral contrast agents (barium sulfate and barium sulfate/ferumoxsil) as a laxative-free fecal tagging prior to the MRC. After MRC, the contrast agent was rated...... qualitatively (with the standard method using contrast-to-wall ratio) and subjectively (using a visual analog scale [VAS]) by three different blinded observers. Results. Evaluated both qualitatively and subjectively, the tagging efficiency of barium sulfate/ferumoxsil was significantly better (P ... barium sulfate alone. The VAS method for evaluating the tagging efficiency of contrast agents showed a high correlation (observer 11, r = 0.91) to the standard method using contrast-to-wall ratio and also a high interclass correlation (observer 11 and III = 0.89/0.85). MRC found I of 22 (5%) polyps

  20. Intussusception reduction: Effect of air vs. liquid enema on radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, Summer L.; Edgar, J.C.; Anupindi, Sudha A.; Zhu, Xiaowei [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); University of Pennsylvania, Perelman School of Medicine, Philadelphia, PA (United States); Magill, Dennise; Felice, Marc A. [University of Pennsylvania, Environmental Health and Radiation Safety, Philadelphia, PA (United States)

    2017-10-15

    Both air and radiopaque liquid contrast are used to reduce ileocolic intussusception under fluoroscopy. Some suggest air lowers radiation dose due to shorter procedure times. However, air enema likely lowers radiation dose regardless of fluoroscopy time due to less density over the automatic exposure control cells. We test the hypothesis that air enema reduction of ileocolic intussusception results in lower radiation dose than liquid contrast enema independent of fluoroscopy time. We describe a role for automatic exposure control in this dose difference. We retrospectively evaluated air and liquid intussusception reductions performed on a single digital fluoroscopic unit during a 26-month period. We compared patient age, weight, gender, exam time of day and year, performing radiologist(s), radiographic image acquisitions, grid and magnification use, fluoroscopy time and dose area product. We compared categorical and continuous variables statistically using chi-square and Mann-Whitney U tests, respectively. The mean dose area product was 2.7-fold lower for air enema, 1.3 ± 0.9 dGy.cm{sup 2}, than for liquid, 3.5 ± 2.5 dGy.cm{sup 2} (P<0.005). The mean fluoroscopy time was similar between techniques. The mean dose area product/min was 2.3-fold lower for air, 0.6 ± 0.2 dGy.cm{sup 2}/min, than for liquid, 1.4 ± 0.5 dGy.cm{sup 2}/min (P<0.001). No group differences were identified in other measured dose parameters. Fluoroscopic intussusception reduction using air enema uses less than half the radiation dose of liquid contrast enema. Dose savings are independent of fluoroscopy time and are likely due to automatic exposure control interaction. (orig.)

  1. Follow-up barium study after a negative water-soluble contrast examination for suspected esophageal leak: is it necessary?

    Science.gov (United States)

    Sanchez, Thomas R; Holz, Grant S; Corwin, Michael T; Wood, Robert J; Wootton-Gorges, Sandra L

    2015-10-01

    The purpose of this study was to determine the value of follow-up barium esophogram in diagnosing esophageal injury or leak if the initial water-soluble contrast examination of the esophagus is normal. An institutional review board (IRB)-approved retrospective review of all pediatric patients less than 18 years old referred to the radiology department for evaluation of esophageal injury or leak was performed for a 9-year period from 2005 to 2014. The majority of patients had unexplained pneumomediastinum, chest trauma (gunshot or puncture wound), or foreign body ingestion as the reason for the referral. Forty-nine patients (age range 10 days to 17 years) underwent an initial water-soluble esophogram immediately followed by a barium esophogram. Forty-six studies were negative on both water-soluble contrast and barium studies. Two studies were both positive on the initial water-soluble contrast and subsequent barium studies. A single study showed the esophageal leak only in the water-soluble study, with the follow-up barium exam being normal. The result of this study indicates that a single-contrast water-soluble esophogram alone is sensitive in the diagnosis of esophageal injury or leak. It has a 100 % sensitivity and negative predictive value. A follow-up barium esophogram only increases the study time and radiation dose to the patient.

  2. MDCT appearance of the appendix: how does the low-density barium sulfate oral contrast agent affect it?

    Science.gov (United States)

    Yaghmai, Vahid; Aghaei-Lasboo, Anahita; Brandwein, Warren M; Tochetto, Sandra; Mafi, John N; Miller, Frank H; Nikolaidis, Paul

    2011-01-01

    We compared the effect of low-density barium sulfate neutral oral contrast agent on the diameter of normal appendix and its luminal content versus that of water on multidetector-row CT. CT scans of 24 patients who had been imaged on two separate occasions for the evaluation of pancreatic pathology, once with water and subsequently with low-density barium sulfate as the neutral oral contrast agent were evaluated (total of 48 scans). Studies were randomized and reviewed in consensus on a workstation in the stack mode by two radiologists blinded to the type of oral contrast. The appendix was measured at baseline and 10 days later to obtain an average diameter. Results of the water and low-density barium sulfate groups were compared using paired t test. Contents of the appendiceal lumen were also noted (gas, fluid, mixed, and collapsed appendix). The average diameter of the appendix for scans obtained with water and low-density barium sulfate was 4.09 ± 0.87 mm (median, 4.22 mm; range, 2.50-5.65 mm) and 4.13 ± 0.93 mm (median, 4 mm, range, 2.2-5.65 mm), respectively. This difference was not statistically significant (P = 0.69). There was no statistically significant difference in the appendiceal content when water or low-density barium sulfate were used as oral contrast (χ (2) = 4.25, P = 0.89). Low-density barium sulfate does not affect appendiceal content or diameter and, therefore, should not adversely affect evaluation of the appendix on multidetector row CT.

  3. A radiologic evaluation of bladder tumors on barium air double contrast cystography and triple-fractionated cystography

    International Nuclear Information System (INIS)

    Hur, W. J.; Jang, H. Y.; Sol, C. H.; Kim, B. S.

    1984-01-01

    Clinically bladder tumors can be easily diagnosed on cystoscopic examination and biopsy in the patients with silent hematuria, terminal dribbling and dysuria. But for the evaluation of the extent of tumor invasion, the authors performed both barium-air double contrast and triple-fractionated cystography on 16 patients suspected to be bladder tumor on cystoscopic examination in the radiologic department of B.N.U.H. from September 1982 to August 1983. The obtained results were summarized as follows. 1. On barium-air double contrast cystography and triple-fractionated cystography, 13 cases were concluded as bladder tumor, and 3 cases were consistent with the findings of chronic inflammation out of the total 16 cases. 2. After operation of 15 cases, 12 cases were confirmed pathologically as transitional cell carcinoma, 1 case as prostatic hypertrophy, and 2 cases as chronic inflammation. Remaining one was biopsied on cystoscopic examination, and confirmed as chronic inflammation. 3. Among 9 cases of transitional cell carcinoma having the evidence of muscle invasion on triple- fractionated cystography, 8 cases were confirmed as more than stage B 1 on pathologic study, and the other as chronic inflammation. 4. In detecting multiplicity, presence of ulceration, and evaluation of nature of tumor surface, barium- air double contrast cystogrpahy was more excellent than cystoscopic results. 5. Cases presenting both ulceration and cauliflower appearance on barium- air double contrast cystography was more than grade III on microscopic evaluation. 6. In conclusion, the authors considers the barium-air double contrast and triple-fractionated cystography are easy to perform, reasonable in price and have relatively high accuracy in tumor detection, staging and grading.

  4. Peripheral blood eosinophilia associated with gastrointestinal administration of iodinated contrast media.

    Science.gov (United States)

    Plavsic, Branko M; Newman, Alan C; Reuther, Warren L; Terry, James A; Drnovsek, Valerie H

    2003-03-01

    This study was designed to assess whether gastrointestinal administration of iodinated contrast media results in peripheral blood eosinophilia. We studied 110 patients in a retrospective review. Diatrizoate meglumine and diatrizoate sodium for abdominal CT were administered to 98 of these patients; 22 of the 98 had also been given the same contrast medium administered by enema. The remaining 12 patients were given diatrizoate sodium for gastrointestinal fluoroscopy. A control group of 65 patients underwent single-contrast barium upper gastrointestinal or enema examinations. WBC and eosinophil counts were determined approximately 24 hr before the examination and every 24 hr thereafter, through the ninth day. Eosinophilia was detected in 17 (15.5%) of 110 patients after gastrointestinal administration of iodinated contrast media. The prevalence of eosinophilia after administration of iodinated contrast media was statistically significantly different compared with that in the control group, in which none of the 65 patients had eosinophilia (p contrast agents and lasted through the sixth day, with a peak on the fifth day. The prevalence of eosinophilia was independent of route of application, dose, or type of iodinated contrast medium. Eosinophilia in all cases was clinically asymptomatic. Eosinophilia that is caused by gastrointestinal administration of iodinated contrast media is a transient, clinically silent phenomenon. It may lead to unnecessary workup for known conditions associated with eosinophilia.

  5. Effect of barium sulfate contrast medium on rheology and sensory texture attributes in a model food.

    Science.gov (United States)

    Ekberg, O; Bulow, M; Ekman, S; Hall, G; Stading, M; Wendin, K

    2009-03-01

    The swallowing process can be visualized using videoradiography, by mixing food with contrast medium, e.g., barium sulfate (BaSO(4)), making it radiopaque. The sensory properties of foods may be affected by adding this medium. To evaluate if and to what extent sensory and rheological characteristics of mango purée were altered by adding barium sulfate to the food. This study evaluated four food samples based on mango purée, with no or added barium sulfate contrast medium (0%, 12.5%, 25.0%, and 37.5%), by a radiographic method, and measured sensory texture properties and rheological characteristics. The sensory evaluation was performed by an external trained panel using quantitative descriptive analysis. The ease of swallowing the foods was also evaluated. The sensory texture properties of mango purée were significantly affected by the added barium in all evaluated attributes, as was the perception of particles. Moreover, ease of swallowing was significantly higher in the sample without added contrast medium. All samples decreased in extensional viscosity with increasing extension rate, i.e., all samples were tension thinning. Shear viscosity was not as dependent on the concentration of BaSO(4) as extensional viscosity. Addition of barium sulfate to a model food of mango purée has a major impact on perceived sensory texture attributes as well as on rheological parameters.

  6. Water soluble contrast enema examination of the integrity of the rectal anastomosis prior to loop ileostomy reversal may be superfluous.

    Science.gov (United States)

    Larsson, Anna; Lindmark, Gudrun; Syk, Ingvar; Buchwald, Pamela

    2015-03-01

    Defunctioning loop ileostomy in low anterior resection (LAR) is routinely used to reduce consequences of anastomotic leakage. The purpose of this study was to analyze which examination technique is optimal for evaluating the integrity of the anastomosis prior to loop ileostomy reversal. Retrospective analysis of 95 patients who had been subjected to LAR at Helsingborg Hospital and Skåne University Hospital, Sweden, was undertaken between January 2007 and June 2009. The examination techniques of the rectal anastomosis prior to reversal and the clinical outcome after reversal were studied. Radiologic anastomosis control using water soluble contrast enema, digital rectal examination (DRE), and rectoscopy were performed in 53 % (50/95), 98 % (93/95), and 69 % (66/95), respectively. In two patients, no control of the anastomosis was performed before reversal. Fifty-two percent (49/95) of the patients were examined using all techniques. Six patients demonstrated leakage detected before reversal of which two were only radiological leakages. These two patients underwent loop ileostomy reversal after delay without complications. They were the only ones where the three examination techniques did not prove coherence. Four patients had symptomatic leakage; these were detected with rectoscopy and DRE and verified with enema. Three patients developed anastomotic leakage after loop ileostomy reversal despite normal preoperative examinations. Two of these patients had rectovaginal fistulas (AVFs). This retrospective study indicates that contrast enema does not provide additional information if rectoscopy and DRE are normal. Despite negative examinations, three of nine leakages were diagnosed after loop ileostomy reversal. Especially, AVFs seem difficult to diagnose.

  7. Effect of barium-coated halloysite nanotube addition on the cytocompatibility, mechanical and contrast properties of poly(methyl methacrylate) cement.

    Science.gov (United States)

    Jammalamadaka, Uday; Tappa, Karthik; Weisman, Jeffery A; Nicholson, James Connor; Mills, David K

    2017-01-01

    Halloysite nanotubes (HNTs) were investigated as a platform for tunable nanoparticle composition and enhanced opacity in poly(methyl methacrylate) (PMMA) bone cement. Halloysite has been widely used to increase the mechanical properties of various polymer matrices, in stark contrast to other fillers such as barium sulfate that provide opacity but also decrease mechanical strength. The present work describes a dry deposition method for successively fabricating barium sulfate nanoparticles onto the exterior surface of HNTs. A sintering process was used to coat the HNTs in barium sulfate. Barium sulfate-coated HNTs were then added to PMMA bone cement and the samples were tested for mechanical strength and tailored opacity correlated with the fabrication ratio and the amount of barium sulfate-coated HNTs added. The potential cytotoxic effect of barium-coated HNTs in PMMA cement was also tested on osteosarcoma cells. Barium-coated HNTs were found to be completely cytocompatible, and cell proliferation was not inhibited after exposure to the barium-coated HNTs embedded in PMMA cement. We demonstrate a simple method for the creation of barium-coated nanoparticles that imparted improved contrast and material properties to native PMMA. An easy and efficient method for coating clay nanotubes offers the potential for enhanced imaging by radiologists or orthopedic surgeons.

  8. In vitro experiments for the development of a high density (HD) barium sulfate contrast medium

    International Nuclear Information System (INIS)

    Klein, J.

    1986-01-01

    In vitro experiments with the high-density (HD) barium meal Falibaryt HD are described. Several charges of BaSO 4 were tested together with certain additives influencing dispersion, stability of the suspension, flowability, surface tension etc. Particle size spectra were measured by the manufacturer, VEB Fahlberg-List. With a simple PVC test plate containing several grooves simulating small details (areae gastricae) the diagnostic capabilities of the HD contrast medium were evaluated in an in vitro test. The developed barium meal Falibaryt HD is in its physical and chemical parameters comparable with Prontobario-HD, one of the best HD barium meals. (author)

  9. Effect of barium-coated halloysite nanotube addition on the cytocompatibility, mechanical and contrast properties of poly(methyl methacrylate cement

    Directory of Open Access Journals (Sweden)

    Jammalamadaka U

    2017-06-01

    Full Text Available Uday Jammalamadaka,1 Karthik Tappa,1 Jeffery A Weisman,1 James Connor Nicholson,2 David K Mills1,3 1Center for Biomedical Engineering and Rehabilitation Science, 2Nanosystems Engineering, 3The School of Biological Sciences, Louisiana Tech University, Ruston, LA, USA Abstract: Halloysite nanotubes (HNTs were investigated as a platform for tunable nanoparticle composition and enhanced opacity in poly(methyl methacrylate (PMMA bone cement. Halloysite has been widely used to increase the mechanical properties of various polymer matrices, in stark contrast to other fillers such as barium sulfate that provide opacity but also decrease mechanical strength. The present work describes a dry deposition method for successively fabricating barium sulfate nanoparticles onto the exterior surface of HNTs. A sintering process was used to coat the HNTs in barium sulfate. Barium sulfate-coated HNTs were then added to PMMA bone cement and the samples were tested for mechanical strength and tailored opacity correlated with the fabrication ratio and the amount of barium sulfate-coated HNTs added. The potential cytotoxic effect of barium-coated HNTs in PMMA cement was also tested on osteosarcoma cells. Barium-coated HNTs were found to be completely cytocompatible, and cell proliferation was not inhibited after exposure to the barium-coated HNTs embedded in PMMA cement. We demonstrate a simple method for the creation of barium-coated nanoparticles that imparted improved contrast and material properties to native PMMA. An easy and efficient method for coating clay nanotubes offers the potential for enhanced imaging by radiologists or orthopedic surgeons. Keywords: barium, bone cement, halloysite, imaging, PMMA, sintering

  10. Elevated Z line: a new sign of Barrett's esophagus on double-contrast barium esophagograms.

    Science.gov (United States)

    Levine, Marc S; Ahmad, Nuzhat A; Rubesin, Stephen E

    2015-01-01

    We describe an elevated Z line as a new radiographic sign of Barrett's esophagus characterized by a transversely oriented, zigzagging, barium-etched line extending completely across the circumference of the midesophagus. An elevated Z line is rarely seen in other patients, so this finding should be highly suggestive of Barrett's esophagus on double-contrast barium esophagograms. If the patient is a potential candidate for surveillance, endoscopy and biopsy should be performed to confirm the presence of Barrett's esophagus. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Evaluation of Patient Skin Effective Dose Due to Diagnostic ...

    African Journals Online (AJOL)

    The common procedures are the plain radiographs of the chest, skull, cervical spine, sinus, lumbosacral spine, pelvis, abdomen, shoulder and foot and hysterosalpingography (HSG), intravenous urography, barium meal and barium enema are the special or contrast procedures. 1977 procedures were monitored in some ...

  12. Technical quality of lower intestinal tract contrast examination

    International Nuclear Information System (INIS)

    Araujo, Antonio L.E. de; Rodrigues, Rosana S.; Brasil, Flavio A.; Carmo, Maria L.R. do; Quinonez, Mireya D.; Peli, Ling Pei Huang; Moraes, Monica M. de; Pereira, Abercio A.; Koch, Hilton A.

    1996-01-01

    This work is an investigation of the quality of a barium enema examination release on the Hospital Universitario Clementino Fraga Filho radiodiagnostic service. A sectional study was carried out from March 1994 and will continue till February 1995. The elaboration of a questionary was originated by the necessity of establishing quality control, evaluate their diagnosis usefulness and cost analysis. Data was obtained from patient's dossiers as well as from careful radiological examination analysis. A quantification formulary allowed standardization of the results and also the construction of a data bank. Finally, the authors analyze the several variables like preliminary cleansing of the colon, contrast media characters, techniques of examination performance and other factors that influence the final quality of the examination. (author)

  13. Effects of barium sulfate as a contrast medium to enterocutaneous fistulas

    International Nuclear Information System (INIS)

    Pelster, F.W.; Reichelt, S.; Arndt, M.; Eising, E.G.

    1989-01-01

    Fistulation following thoracic and epigastric interventions are conservatively treated, as a rule, because of the high rate of complications expected from reoperation. With properly functioning anastomotic transit, insufficiencies usually undergo spontaneous healing, within four to six weeks. Enterocutaneous fistulae developed in 29 of 271 patients with intrathoracic oesophagastric or oesophagojejunal anastomosis. Syringeal ramification into pleural or abdominal cavities were eliminated by means of an absorbable contrast medium, before barium sulphate was orally administered to all patients. Thoracic fistulae were closed after 21.8 days on average, while 20.3 days was the average period required for closure of epigastric fistulae. Barium sulphate was found to stimulate fistular tissue granulation, so that obliteration of the fistular system occurred much sooner, as compared to conservative treatment. The patient's quality of life can thus be improved, and hospitalisation can be shortened. Neither locally delimited nor systemic complications were observed in any of the cases described. (author)

  14. Colonic motility and enema spreading

    International Nuclear Information System (INIS)

    Hardy, J.G.; Wood, E.; Clark, A.G.; Reynolds, J.R.; Queen's Medical Centre, Nottingham

    1986-01-01

    Radiolabelled enema solution was administered to eight healthy subjects, both in fasted and fed states. Enema spreading was monitored over a 4-h period using gamma scintigraphy and colonic motility was recorded simultaneously using a pressure sensitive radiotelemetry capsule. The rate and extent of enema dispersion were unaffected by eating. Spreading could be correlated with colonic motility and was inhibited by aboral propulsion of the colonic contents. (orig.)

  15. Comparative evaluation of positive contrast and double contrast gastrography in dogs

    International Nuclear Information System (INIS)

    Dileepkumar, K.M.; Rajankutty, K.; Sarada, Amma T.; Devanand, C.B.; Vijayan, N.

    2012-01-01

    A contrast radiography of stomach with oral barium sulphate suspension 25% (5 mL/kg b.wt positive contrast) and double contrast with oral barium sulphate 25% (3 mL/kg b.wt) followed by air (2 to 10 mL/kg b.wt, negative contrast) was done on six dogs to study the affections of stomach. Contrast radiography using barium sulphate alone was found satisfactory to identify most of the lesions of the stomach. Double contrast radiography using barium sulphate and air, required sedation to control the animals for proper administration. For the diagnosis of mucosal lesions, double contrast radiography was better than barium sulphate alone. Key words: Barium, Contrast radiography, Dog, Double contrast, Stomach

  16. Barium sulphate preparations for use in double contrast examination of the upper gastrointestinal tract

    International Nuclear Information System (INIS)

    Anderson, W.; Harthill, J.E.; James, W.B.; Montgomery, D.

    1980-01-01

    Physical properties relevant to upper gastrointestinal radiology have been compared for five barium sulphate preparations and related to radiographic results. Evaluation of particles (size and stability) and whole suspension (dispersibility and fluidity) resulted in ranking of the preparations generally in accord with that based on radiological experience in double contrast examinations of the stomach. Experiments with extirpated pig stomach revealed a tendency for large particles in a low viscosity barium sulphate suspension to settle in mucosal grooves. This is believed to contribute to good radiographic definition of both the areae gastricae and small lesions. Particle size is therefore important and susceptibility to flocculation, a possible cause of random change in size during use, was assessed by measuring particle electrophoretic mobility under varying conditions; quantitative differences in suspension flow and dispersibility were also demonstrated. Fluidity and dispersibility together with rapid sedimentation of suitably sized particles resistant to flocculation underlie the successful use of low viscosity high density barium sulphate suspensions. (U.K.)

  17. Adverse effects and complications related to the use of barium sulphate contrast media for radiological examinations of the gastrointestinal tract - a literature review

    International Nuclear Information System (INIS)

    Periard, M.A.

    2003-01-01

    Barium sulphate is considered a safe and efficacious contrast medium that is routinely used for radiologic examinations of the gastrointestinal tract. Although the examinations rarely result in complications, the technique is moderately invasive and not entirely innocuous. Complications resulting from the procedures, and adverse reactions from the barium itself, have ranged from mild to severe and in rare instances have led to patient death. This paper reviews the clinical application, biological requirements and clinical properties of barium sulphate contrast media used in diagnostic x-ray imaging. It also outlines the risk factors and associated adverse reactions and complications involved with the use of barium sulphate, and presents documented cases where iatrogenic injuries have resulted. (author)

  18. Use of negative contrast computed tomography for diagnosis of a colonic duplication in a dog.

    Science.gov (United States)

    de Battisti, A; Harran, N; Chanoit, G; Warren-Smith, C

    2013-10-01

    A 24-week-old dog was presented with recurrent rectal prolapse because of colonic duplication. Colonic duplication is an extremely uncommon congenital abnormality, with only six cases reported in veterinary medicine, one diagnosed at necropsy and five after barium enema, colonoscopy, abdominal ultrasound, exploratory laparotomy either alone or in combination. In this case, these techniques failed to identify the abnormality and diagnosis was ultimately achieved via negative contrast computed tomography. The evaluation generated by the computed tomography images allowed a refined surgical approach. To the authors' knowledge, negative contrast computed tomography has not yet been reported in the veterinary literature to diagnose gastrointestinal pathologies. Colonic duplication in this case was treated by removal of the intercolonic septum via colotomy. © 2013 British Small Animal Veterinary Association.

  19. Effects of high volume saline enemas vs no enema during labour – The N-Ma Randomised Controlled Trial [ISRCTN43153145

    Directory of Open Access Journals (Sweden)

    Bernal María

    2006-03-01

    Full Text Available Abstract Background Enemas are used during labour in obstetric settings with the belief that they reduce puerperal and neonatal infections, shorten labour duration, and make delivery cleaner for attending personnel. However, a systematic review of the literature found insufficient evidence to support the use of enemas. The objective of this RCT was to address an identified knowledge gap by determining the effect of routine enemas used during the first stage of labour on puerperal and neonatal infection rates. Methods Design: RCT (randomised controlled trial; randomized clinical trial. Outcomes: Clinical diagnosis of maternal or neonatal infections, labour duration, delivery types, episiotomy rates, and prescription of antibiotics Setting: Tertiary care referral hospital at the Javeriana University (Bogotá, Colombia that attended 3170 births during study period with a caesarean section rate of 26%. Participants: 443 women admitted for delivery to the obstetrics service (February 1997 to February 1998 and followed for a month after delivery. Inclusion criteria were women with: low risk pregnancy and expected to remain in Bogotá during follow up; gestational age ≥ 36 weeks; no pelvic or systemic bacterial infection; intact membranes; cervix dilatation ≤7 cm. Intervention: 1 litre saline enema, versus no enema, allocated following a block random allocation sequence and using sealed opaque envelopes. Results Allocation provided balanced groups and 86% of the participants were followed up for one month. The overall infection rate for newborns was 21%, and 18% for women. We found no significant differences in puerperal or neonatal infection rates (Puerperal infection: 41/190 [22%] with enema v 26/182 [14%] without enema; RR 0.66 CI 95%: 0.43 to 1.03; neonatal infection 38/191 [20%] with enema v 40/179 [22%] without enema; RR 1.12, 95% CI 95% 0.76 to 1.66, and median labour time was similar between groups (515 min. with enema v 585 min. without

  20. The utility of the contrast enema in neonates with suspected Hirschsprung disease.

    Science.gov (United States)

    Putnam, Luke R; John, Susan D; Greenfield, Susan A; Kellagher, Caroline M; Austin, Mary T; Lally, Kevin P; Tsao, Kuojen

    2015-06-01

    The contrast enema (CE) is commonly utilized for suspected Hirschsprung disease (HD) patients. We set out to determine the utility of the CE in the newborn for clinically suspicious HD. All CEs performed for suspicion of HD in neonates from January 2004 to December 2013 were reviewed by two pediatric radiologists who were blinded to the original interpretations and final diagnoses. A standardized scoring sheet was utilized to document essential radiographic findings. Definitive diagnoses were determined by pathology. Descriptive statistics, likelihood ratios, and interrater agreement were determined. 158 CEs were reviewed. Interrater agreement was 89% with kappa (95% CI) of 0.63 (0.47-0.76). Common indications for CE were similar between non-HD and HD groups. The positive, inconclusive, and negative likelihood ratios (95% CI) were 38 (10-172), 3.2 (1.3-9.1), and 0.15 (0.06-0.47), respectively, leading to posttest probabilities for positive, inconclusive, and negative tests of 83%, 32%, and 2.5%, respectively. Although radiographic positive CE for HD portends a high probability of HD, inconclusive studies still represent a significant increased risk. In clinically suspicious infants for HD, those with inconclusive studies may benefit from a lower threshold to perform follow-up rectal biopsy. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Development of a new high density (HD) barium meal (Falibaryt HD) for double contrast investigation of the stomach

    International Nuclear Information System (INIS)

    Dietze, R.

    1986-01-01

    During the development of a new double contrast barium meal barium sulfate preparations with various densities, additives and particle size distributions were tested. Phantoms made of leather, rubber and the opened stomachs of cows and pigs were used. A HD bariumsulfate suspension (200 - 250% W/V) of low viscosity and suitable grain size spectrum containing additives improving the adherence (e.g. natrium citrate) showed the best quality parameters for an optimal imaging of the fine mucosal relief. (author)

  2. Comparison of pressure between barium reduction and air reduction of the intussusception in children

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Park, Sang Gyu; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1989-08-15

    There are many method of treatment of the intussusception in children, including surgery, barium reduction, air reduction, and saline enema under ultrasonographic monitoring. Among them, barium reduction and air reduction have been used widely as nonsurgical method of treatment in radiologic department. During barium reduction, the bottle filled with barium solution must not be elevated over a 3 feet from the operating table. In air reduction, diagnostic pressure is about 60 mmHg and pressure during reduction usually is maintained between 90 mmHg and 130 mmHg. The authors have studied about pressure difference of barium solution by changing height of the bottle filled with barium solution, and have compared with pressure in air reduction. The results are as follows; 1. Pressure of 20 w/v % barium solution at the 60 cm height is 44.4 mmHg, and 69.6 mmHg at the 90 cm height. 2. Pressure of 40 w/v % barium solution at the 60 cm height is 51.4 mmHg, and 80.1 mmHg at the 90 cm height. 3. Pressure of 40 w/v % barium solution at the 90cm height is much lower than the pressure maintained during air reduction, and this difference in pressure may be one of the causes of low reduction rate in barium reduction then air reduction. 4. The pressure gradient per 10 cm height is about 8.45 mmHg in 20 w/v % barium solution, about 9.21 mmHg in 30 w/v % barium solution, and about 9.72 mmHg 40 w/v % barium solution. 5. Intraluminal pressure difference between the barium reduction and the air reduction is probably of the major causes of rapid diagnosis and high reduction rate in the air reduction.

  3. Comparison of pressure between barium reduction and air reduction of the intussusception in children

    International Nuclear Information System (INIS)

    Lee, Kyung Hwan; Park, Sang Gyu; Park, Choong Ki; Yoon, Jong Sup

    1989-01-01

    There are many method of treatment of the intussusception in children, including surgery, barium reduction, air reduction, and saline enema under ultrasonographic monitoring. Among them, barium reduction and air reduction have been used widely as nonsurgical method of treatment in radiologic department. During barium reduction, the bottle filled with barium solution must not be elevated over a 3 feet from the operating table. In air reduction, diagnostic pressure is about 60 mmHg and pressure during reduction usually is maintained between 90 mmHg and 130 mmHg. The authors have studied about pressure difference of barium solution by changing height of the bottle filled with barium solution, and have compared with pressure in air reduction. The results are as follows; 1. Pressure of 20 w/v % barium solution at the 60 cm height is 44.4 mmHg, and 69.6 mmHg at the 90 cm height. 2. Pressure of 40 w/v % barium solution at the 60 cm height is 51.4 mmHg, and 80.1 mmHg at the 90 cm height. 3. Pressure of 40 w/v % barium solution at the 90cm height is much lower than the pressure maintained during air reduction, and this difference in pressure may be one of the causes of low reduction rate in barium reduction then air reduction. 4. The pressure gradient per 10 cm height is about 8.45 mmHg in 20 w/v % barium solution, about 9.21 mmHg in 30 w/v % barium solution, and about 9.72 mmHg 40 w/v % barium solution. 5. Intraluminal pressure difference between the barium reduction and the air reduction is probably of the major causes of rapid diagnosis and high reduction rate in the air reduction

  4. In vitro tests of barium sulphate suspensions for double contrast examinations of the stomach

    International Nuclear Information System (INIS)

    Treugut, H.; Huebener, K.H.

    1980-01-01

    Four barium sulphate suspensions were investigated with respect to their adhesion and contrast following standard means of spreading the contrast over a model stomach, which corresponds in its detailed structure with the surface of the gastric mucosa. By this means various factors, which make a true comparison in vivo impossible, could be eliminated and a comparison of the suspensions became possible. Using similar mechanical and chemical situations, the radiographs of the artificial mucosa showed very different results from the use of the different preparations. These corresponded well with the findings in vivo. (orig.) [de

  5. The review of 134 cases colon and rectal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chung Kyu; Choi, Byung Sook [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1971-10-15

    Barium Enema study for colon examination is of great importance in the health care of our people and its value can be increased by a wide understanding of the attendant difficulties and limitation. Since the incidence of the colon and rectal carcinoma is increasing, the barium enema examination is more valuable. Radiologically diagnosed 134 cases of colon and rectal carcinoma from January 1964 to June 1970 have been reviewed at Yensei Univ., College of Medicine. Among the total admission during these years, the ratio of the colon and rectal carcinoma was 0.29 percent, and the incidence among barium enema examination was 5.3%. The peak age range was between 40 and 50 years. The average age of the patients was 46 years. It was more common in male. The clinical picture was rather vague in some cases, especially in the lesions of right colon. The large number of cases has bowel habit change, tarry or bloody stool and abdominal pain. About 60% of the lesions were located in rectum and 40% was proximal portion from the rectum, which could not be completely diagnosed only by digital examination and proctosigmoidoscopy. On roentgenogram, the most common form was encircling type, next was fungating. The positivity for accuracy of the barium enema examination was 90%. Majority of cancers of the colon, particularly those that produce symptoms are relative gross lesions. In daily practise we have to eager to find out small lesions by repeat and complete barium enema examination, including double contrast study. Early diagnosis is an aid immediate, logical objective in attempts to decrease the morbidity and mortality from carcinoma of colon.

  6. The review of 134 cases colon and rectal carcinoma

    International Nuclear Information System (INIS)

    Kim, Chung Kyu; Choi, Byung Sook

    1971-01-01

    Barium Enema study for colon examination is of great importance in the health care of our people and its value can be increased by a wide understanding of the attendant difficulties and limitation. Since the incidence of the colon and rectal carcinoma is increasing, the barium enema examination is more valuable. Radiologically diagnosed 134 cases of colon and rectal carcinoma from January 1964 to June 1970 have been reviewed at Yensei Univ., College of Medicine. Among the total admission during these years, the ratio of the colon and rectal carcinoma was 0.29 percent, and the incidence among barium enema examination was 5.3%. The peak age range was between 40 and 50 years. The average age of the patients was 46 years. It was more common in male. The clinical picture was rather vague in some cases, especially in the lesions of right colon. The large number of cases has bowel habit change, tarry or bloody stool and abdominal pain. About 60% of the lesions were located in rectum and 40% was proximal portion from the rectum, which could not be completely diagnosed only by digital examination and proctosigmoidoscopy. On roentgenogram, the most common form was encircling type, next was fungating. The positivity for accuracy of the barium enema examination was 90%. Majority of cancers of the colon, particularly those that produce symptoms are relative gross lesions. In daily practise we have to eager to find out small lesions by repeat and complete barium enema examination, including double contrast study. Early diagnosis is an aid immediate, logical objective in attempts to decrease the morbidity and mortality from carcinoma of colon

  7. Isoosmolar enemas demonstrate preferential gastrointestinal distribution, safety, and acceptability compared with hyperosmolar and hypoosmolar enemas as a potential delivery vehicle for rectal microbicides.

    Science.gov (United States)

    Leyva, Francisco J; Bakshi, Rahul P; Fuchs, Edward J; Li, Liye; Caffo, Brian S; Goldsmith, Arthur J; Ventuneac, Ana; Carballo-Diéguez, Alex; Du, Yong; Leal, Jeffrey P; Lee, Linda A; Torbenson, Michael S; Hendrix, Craig W

    2013-11-01

    Rectally applied antiretroviral microbicides for preexposure prophylaxis (PrEP) of HIV infection are currently in development. Since enemas (rectal douches) are commonly used by men who have sex with men prior to receptive anal intercourse, a microbicide enema could enhance PrEP adherence by fitting seamlessly within the usual sexual practices. We assessed the distribution, safety, and acceptability of three enema types-hyperosmolar (Fleet), hypoosmolar (distilled water), and isoosmolar (Normosol-R)-in a crossover design. Nine men received each enema type in random order. Enemas were radiolabeled [(99m)Tc-diethylene triamine pentaacetic acid (DTPA)] to assess enema distribution in the colon using single photon emission computed tomography/computed tomography (SPECT/CT) imaging. Plasma (99m)Tc-DTPA indicated mucosal permeability. Sigmoidoscopic colon tissue biopsies were taken to assess injury as well as tissue penetration of the (99m)Tc-DTPA. Acceptability was assessed after each product use and at the end of the study. SPECT/CT imaging showed that the isoosmolar enema had greater proximal colonic distribution (up to the splenic flexure) and greater luminal and colon tissue concentrations of (99m)Tc-DTPA when compared to the other enemas (pgood with no clear preferences among the three enema types. The isoosmolar enema was superior or similar to the other enemas in all categories and is a good candidate for further development as a rectal microbicide vehicle.

  8. Primary double contrast study of the colon with citrate-sorbitol-barium suspension in the diagnosis of chronic colitis

    International Nuclear Information System (INIS)

    Sidorov, V.S.

    1991-01-01

    X-ray investigation of the colon was conducted in 292 patients with clinically diagnosed chronic colitis: standard 3-phase irrigoscopy-in 189 patients and a primary double contrast study of the colon with citrate-sorbitol-barium suspenzion - in 103. Basing on X-ray and morphological findings, the diagnosis was confirmed in 128 patients of the 1st group (68.2 %) and in 89 patients of the 2nd group (86 %). The primary double contrast study of the colon was found more effective as it permitted the detection of elements of the mucosal microcontours: transversal strips, not coinciding with haustration, focal granularity, diffuse granularity, small barium suspension depots or niches, nodular granularity. It permitted the recommendation of the method for a wide clinical use

  9. Survey of effective doses to patients undergoing contrast-based X-ray fluoroscopy procedures in Tanzania

    International Nuclear Information System (INIS)

    Ngaile, J.E.; Msaki, P.K.; Kazema, R.R.

    2017-01-01

    The aim of this study was to assess the radiation burden imparted to patients from contrast-based X-ray fluoroscopy procedures in Tanzania. The effective doses (EDs) to patients from five contrast-based fluoroscopy procedures were obtained from four hospitals. The ED was estimated using the knowledge of the patient characteristics, patient-related exposure parameters, measurements of air kerma area product and PCXCM software. The median EDs for the barium swallow (BS), barium meal (BM), barium enema (BE), hysterosalpingography (HSG) and retrograde urethrography (RUG) were 0.50, 1.43, 2.83, 0.65 and 0.59 mSv, respectively. The median ED per hospital for the BS and BM procedures varied by factors of up to 9.9 and 4.2, respectively, while for the BE, HSG and RUG varied by factors of up to 2.3, 2.4 and 4.3, respectively. The overall differences between individual EDs across the four hospitals varied by factors of up to 53, 58.9 and 11.4 for the BS, BM and BE, respectively, while for the HSG and RUG differed by factors of up to 22 and 46.7, respectively. The mean EDs in this study were mostly lower than reported values from Spain, the UK, Ghana and Greece, while slightly higher than those reported from India. The observed wide variations of procedural protocols and patient doses within and across the hospitals; and the observed high patient doses in this study relative to those from the literature call for the need to standardize procedural protocols and optimize contrast-based fluoroscopy procedures. (authors)

  10. Acquired Salpingo-Enteric Fistula – A Case Report

    African Journals Online (AJOL)

    Erah

    The result showed evidence of opacification of the right fallopian tube with contrast outlining the adjacent large bowels.Asymptomatic pelvic ... barium enema, vaginography, colpography, ultrasonography, computerized axial ... Figure 1: Initial HSG film showing contrast loculation in the right fallopian tube. to a suspicion of ...

  11. Understanding Antegrade Colonic Enema (ACE) Surgery

    Science.gov (United States)

    ... Enema (ACE) Surgery Menu Overview Procedure Details Risks / Benefits What is antegrade colonic enema (ACE) surgery? Antegrade ... Accepted Insurance Make a Donation Refer a Patient Phone Directory Blog, News & Mobile Apps Consult QD Health Essentials Newsroom Mobile Apps ...

  12. Contrast-enhanced computed tomography of the primary tumor in muscle invasive carcinoma of the urinary bladder

    International Nuclear Information System (INIS)

    Sager, E.M.

    1991-01-01

    Patients with muscle invasive carcinoma of the urinary bladder were examined with contrast-enhanced CT of the primary tumor. A specially designed technique was developed to increase the diagnostic potential of CT. The most important points about the technique were controlled filling of the bladder, the use of thin slices, series of scans before and after intravenous injection of contrast medium, and long scanning times in the precontrast series. The absorbed dose to the patient resulting from the new technique was found to be within the range of the dose from urography or barium enema. This dose was considered to be acceptable given the diagnostic gain of the procedure. Features of irradiated bladder tumors were analysed to find which parameter correlated with persistent malignancy. High contrast enhancement of a tumor relative to the bladder wall was found to be the best indicator of a malignant tumour after irradiation. 127 refs

  13. Comparison of Gastrografin to barium sulfate as a gastrointestinal contrast agent in red-eared slider turtles (Trachemys scripta elegans).

    Science.gov (United States)

    Long, Charles Tyler; Page, Richard B; Howard, Antwain M; McKeon, Gabriel P; Felt, Stephen A

    2010-01-01

    Red-eared slider turtles (Trachemys scripta elegans) commonly develop intestinal obstruction. The gastrointestinal transit time in turtles tends to be longer than in other animals, making a rapid diagnosis of obstruction difficult. Fifteen red-eared sliders were given either Gastrografin or 30% w/v barium sulfate orally to compare ease of administration, transit time, and image quality. Each contrast medium was easy to administer but barium sulfate had to be administered more slowly (mean = 40s) than Gastrografin (mean = 20s) to prevent regurgitation. The mean transit and emptying time of Gastrografin was at least 9 h faster than barium sulfate at all time points except gastric transit. Both contrast media had a smooth, uniform appearance that outlined the mucosa with well-defined margins within the stomach and proximal small intestine. Dilution of Gastrografin occurred as it progressed through the intestines, resulting in decreased opacity in the distal small intestine and colon. Pre-administration packed cell volume and total serum protein levels of four turtles receiving Gastrografin were compared with levels at 24-, 96-, and 168-hours postadministration as well as to four control turtles not receiving contrast medium. Packed cell volume and total serum protein levels did not significantly differ among the Gastrografin and control group. From a clinical perspective, administration of Gastrografin allows for quicker results with only minor hematologic changes in red-eared sliders, but visualization of this contrast medium in the lower gastrointestinal tract may be insufficient for an accurate diagnosis.

  14. Multidetector computerized tomography enema versus magnetic resonance enema in the diagnosis of rectosigmoid endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Biscaldi, Ennio, E-mail: ennio.biscaldi@gmail.com [Department of Radiology, Galliera Hospital, via Mura delle Capuccine 14, 16128 Genoa (Italy); Ferrero, Simone, E-mail: simone.ferrero@unige.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Leone Roberti Maggiore, Umberto, E-mail: ulrm@libero.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Remorgida, Valentino, E-mail: vremorgida@yahoo.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Venturini, Pier Luigi, E-mail: venturini@unige.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Rollandi, Gian Andrea, E-mail: rollandi@galliera.it [Department of Radiology, Galliera Hospital, via Mura delle Capuccine 14, 16128 Genoa (Italy)

    2014-02-15

    Purpose: To compare the accuracy of multidetector computerized tomography enema (MDCT-e) and magnetic resonance enema (MRI-e) in determining the presence of sigmoid and rectal endometriotic nodules. Materials and methods: 260 women (32.6 ± 4.3 years) with symptoms suggestive of rectosigmoid endometriosis underwent MDCT-e and MRI-e prior to laparoscopy. After retrograde colonic distention and injection of intravenous contrast medium, patients were scanned on a 64-row MDCT scanner. MRI-e was performed on a 1.5 T magnet using an 8 channels phased array coil; intestinal distention was achieved by introducing in the rectum 250–300 ml of ultrasonographic gel diluted with saline solution. Radiological findings were compared with surgical and histological results. Results: 176 women had rectosigmoid endometriosis at surgery. There was no significant difference in the accuracy of MDCT-e (98.5%) and MRI-e (96.9%) in the diagnosis of sigmoid and rectal endometriosis (p = 0.248). The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of MDCT-e and MRI-e were respectively 98.3%, 98.8%, 99.4%, 96.5%, 81.59, 0.02 and 97.2%, 96.4%, 98.3%, 94.1%, 26.89, 0.03. Conclusions: Both MDCT-e and MRI-e are accurate in the diagnosis of rectal and sigmoid endometriosis.

  15. Multidetector computerized tomography enema versus magnetic resonance enema in the diagnosis of rectosigmoid endometriosis

    International Nuclear Information System (INIS)

    Biscaldi, Ennio; Ferrero, Simone; Leone Roberti Maggiore, Umberto; Remorgida, Valentino; Venturini, Pier Luigi; Rollandi, Gian Andrea

    2014-01-01

    Purpose: To compare the accuracy of multidetector computerized tomography enema (MDCT-e) and magnetic resonance enema (MRI-e) in determining the presence of sigmoid and rectal endometriotic nodules. Materials and methods: 260 women (32.6 ± 4.3 years) with symptoms suggestive of rectosigmoid endometriosis underwent MDCT-e and MRI-e prior to laparoscopy. After retrograde colonic distention and injection of intravenous contrast medium, patients were scanned on a 64-row MDCT scanner. MRI-e was performed on a 1.5 T magnet using an 8 channels phased array coil; intestinal distention was achieved by introducing in the rectum 250–300 ml of ultrasonographic gel diluted with saline solution. Radiological findings were compared with surgical and histological results. Results: 176 women had rectosigmoid endometriosis at surgery. There was no significant difference in the accuracy of MDCT-e (98.5%) and MRI-e (96.9%) in the diagnosis of sigmoid and rectal endometriosis (p = 0.248). The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of MDCT-e and MRI-e were respectively 98.3%, 98.8%, 99.4%, 96.5%, 81.59, 0.02 and 97.2%, 96.4%, 98.3%, 94.1%, 26.89, 0.03. Conclusions: Both MDCT-e and MRI-e are accurate in the diagnosis of rectal and sigmoid endometriosis

  16. Pregnancy outcome after 1st-trimester inadvertent exposure to barium sulphate as a contrast media for upper gastrointestinal tract radiography.

    Science.gov (United States)

    Han, B H; Lee, K S; Han, J Y; Choi, J S; Ahn, H K; Ryu, H M; Yang, J H; Han, H W; Nava-Ocampo, A A

    2011-10-01

    Despite barium being used as a contrast media for decades, the specific assessment of its safety in pregnant women is scarce. We are reporting the favourable pregnancy outcome in women who were inadvertently exposed to barium swallow and associated ionising radiation, early in pregnancy. A control group of age- and gravidity-matched unexposed pregnant women was also included. There were 32 live-born babies in the exposed group and 94 in the control group. Women had undergone diagnostic upper gastrointestinal tract (UGT) fluoroscopic examination at 3.3 ± 1.5 weeks' gestation. Estimated maternal radiation dose secondary to barium swallow varied widely, the maximum dose was estimated to be 2.45 mSv. Similar pregnancy outcomes were observed between the groups. The number of babies born with major malformations was not significantly different (p = 1.0) between cases and controls: one (3.1%) vs three (3.2%), respectively. In conclusion, our small prospective cohort study of women suggests no association between inadvertent exposure to ionising radiation and barium sulphate during fluoroscopic barium swallow and adverse fetal outcomes.

  17. Barium peritonitis following upper gastrointestinal series: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Su Jin; Hwang, Ji Young; Kim, Yong Jin; Hong, Seong Sook [Soonchunhyang University College of Medicine, Seoul Hospital, Seoul (Korea, Republic of)

    2017-06-15

    We report a rare case of barium peritonitis following an upper gastrointestinal (GI) series and its imaging findings in a 74-year-old female. Barium peritonitis is a rare but life-threatening complication of GI contrast investigation. Therefore, clinical awareness of barium peritonitis as a complication of GI tract contrast investigation would help to prevent such a complication and manage the patients properly.

  18. Barium peritonitis following upper gastrointestinal series: A case report

    International Nuclear Information System (INIS)

    Ko, Su Jin; Hwang, Ji Young; Kim, Yong Jin; Hong, Seong Sook

    2017-01-01

    We report a rare case of barium peritonitis following an upper gastrointestinal (GI) series and its imaging findings in a 74-year-old female. Barium peritonitis is a rare but life-threatening complication of GI contrast investigation. Therefore, clinical awareness of barium peritonitis as a complication of GI tract contrast investigation would help to prevent such a complication and manage the patients properly

  19. Radiographic anatomy and barium sulfate contrast transit time of the gastrointestinal tract of bearded dragons (Pogona vitticeps).

    Science.gov (United States)

    Grosset, Claire; Daniaux, Lise; Guzman, David Sanchez-Migallon; Weber, Ernest Scott; Zwingenberger, Allison; Paul-Murphy, Joanne

    2014-01-01

    The positive contrast gastrointestinal study is a common non-invasive diagnostic technique that does not require anesthesia and enables good visualization of the digestive tract. Radiographic anatomy and reference intervals for gastrointestinal contrast transit time in inland bearded dragons (Pogona vitticeps) were established using seven animals administered 15 ml/kg of a 35% w/v suspension of barium by esophageal gavage. Dorso-ventral and lateral radiographic views were performed at 0, 15, 30 min, 1, 2, 4, 6, 8, 12 h, and then every 12 h up to 96 h after barium administration. Gastric emptying was complete at a median time of 10 h (range 4-24 h). Median jejunum and small intestinal emptying times were 1 h (range 30 min-2 h) and 29 h (range 24-48 h), respectively. Median transit time for cecum was 10 h (range 8-12 h). Median time for contrast to reach the colon was 31 h (range 12-72 h) after administration. Results were compared to those obtained in other reptilian species. This technique appeared safe in fasted bearded dragons and would be clinically applicable in other lizard species.

  20. Ultrasound guided reduction of childhood intussusception

    International Nuclear Information System (INIS)

    Yoon, Chong Hyun; Kim, Han Suk

    1986-01-01

    Following on from diagnosis using ultrasound, hydrostatic reduction using saline enema under ultrasound guidance was tried in 20 cases of childhood intussusception. The conclusions were as follows: 1. Success rates of saline enema under ultrasound guidance during a first-8 month period (P1) and a second-10 month period (P2) were 55.6% (5/9) and 54.5% (6/11) respectively. Average success rate was 55% (11/20). 2. During the periods of P1 and P2, no case was reduced by barium enema in 6 cases of failed reduction with saline enema. 3. During the period of P2, 5 cases of successful reduction with saline enema were confirmed by clinical follow-up without barium enema. 4. During the periods of P1 and P2, 9 cases of failed reduction with saline enema were operated, resulting in 6 cases of segmental resection and 3 cases of manual reduction. 5. The obvious advantages of this method are: 1. No radiation hazard. 2. No fear of barium peritonitis. 3. Detection of leading point. 6. With above results, this method could completely replace barium enema. And ultrasonography should be the initial study in the evaluation of intussusception in children and then if necessary, saline enema under ultrasound guidance should be done.

  1. [Tetany secondary to phosphate enema toxicity, case report].

    Science.gov (United States)

    Núñez Sánchez, María José; Leighton Swaneck, Sofía; Díaz, Franco

    2017-06-01

    Phosphate enemas are frequently used in the treatment of constipation. Errors in dosage and administration can lead to severe complications. To report a case of severe toxicity of phosphate enemas in a child with no risk factors. 2 years old female, with functional constipation, was brought to emergency department because abdominal pain. She was diagnosed with fecal impaction and received half a bottle of Fleet Adult® (Laboratorio Synthon, Chile) two times, with no clinical resolution, deciding to start proctoclisis in pediatric ward. Soon after admission, she presented painful tetany, but alert and oriented. Patient was transferred to PICU where severe hyperphosphatemia and secondary hypocalcemia were confirmed. Her treatment included electrolyte correction; removal of residual phosphate enema and hyperhydration. Tetany resolved over 2 hours after admission and no other complications. Proctoclisis was performed and patient was discharged three days after admission with pharmacological management of constipation. Phosphate enemas may cause serious complications in children with no risk factors. Errors in dosage, administration and removal of the enema are causes of toxicity in this group. Pediatricians and health personnel must be aware of risks and signs of toxicity of phosphate enema.

  2. Experimental studies on the development of Falibaryt HD, a new high density barium meal for double contrast examination of the stomach

    International Nuclear Information System (INIS)

    Dietze, R.

    1985-01-01

    During the development of a new double contrast barium meal barium sulfate preparations with different densities, additives and particle size distributions were tested. Phantoms made of leather, rubber and dissected stomachs of cows and pigs. High density bariumsulfat suspension (200 - 250 % weight/volume) of low viscosity and suitable particle size spectrum containing additives improving the adherence (e.g. natrium citrate) displayed the best quality parameters for optimal imaging of the fine mucosal relief. (author)

  3. Indications for repeated enema reduction of intussusception in children

    Directory of Open Access Journals (Sweden)

    Vujović Dragana

    2014-01-01

    Full Text Available Introduction. Intussusception is a common abdominal emergency in early childhood. It is idiopathic in more than 90% of cases with incidence of 1.5-4 per 1,000 live births. The treatment of choice is nonoperative hydrostatic or air enema reduction. Objective. The aim of the study was to evaluate the influence of clinical presentation and symptom duration in non-operative treatment, considering the indications for delayed enema reduction and its efficacy. Methods. From the total number of 107 patients with intusussception, aged from 2 months to 14 years (median 9 months, 102 (95% patients with ileo-colic intussusceptions were treated initially by ultrasound guided saline enema. Records were reviewed for patients with failed initial treatment and delayed repeated enemas or operative procedure. The predictor variable included duration of presenting symptoms. Results. Successful treatment by hydrostatic saline enemas had 58/102 (57% patients. Success in reduction was greater if symptom duration was 24 hours, (4/45 cases; 9%. Despite failed initial attempts, enema reduction was reattempted in 12 patients, with success in 7/12 (60% patients. Children with symptom duration >24 hours had a greater risk of requiring surgery (41/45 cases; 91%, p<0.001, including 5 (5% patients with ileo-ileal intussusceptions. Conclusion. The accuracy of ultrasound guided saline enema in intussusception reduction is high. Delay in presentation decreases success of non-operative treatment. Delayed enema reduction is important therapeutic option for intussusceptions. Surgical treatment is indicated in cases of complications.

  4. Radiological observations of the thorax and abdomen of the piglet

    International Nuclear Information System (INIS)

    Wood, A.K.W.

    1985-01-01

    A contrast radiographic study of the urinary and gastrointestinal system was carried out in 43 animals, with the aid of barium sulfate, orally for esophageal, stomach, small intestine and large intestine studies; barium sulfate as an enema to complete the large intestine studies; sodium and meglumine diatrizoate intravenously for urography and iodipamide meglumine intravenously for cholecystography. Both unanesthetized and anesthetized or tranquilized animals were used in the study. The results of the study are illustrated, and contrasted with studies of a similar nature in other animals

  5. Barium Sulfate

    Science.gov (United States)

    ... uses a computer to put together x-ray images to create cross-sectional or three dimensional pictures of the inside of the body). Barium sulfate is in a class of medications called radiopaque contrast media. It works by coating the esophagus, stomach, or ...

  6. Prognostic model for patients treated for colorectal adenomas with regard to development of recurrent adenomas and carcinoma

    DEFF Research Database (Denmark)

    Jensen, P; Krogsgaard, M R; Christiansen, J

    1996-01-01

    -80. INTERVENTIONS: All patients were followed up by rectoscopy and double contrast barium enema. The survival data were analysed by Cox's proportional hazards model. MAIN OUTCOME MEASURES: Variables of significant prognostic importance for recurrence of adenomas and the development of cancer were identified...

  7. Therapeutic High-Density Barium Enema in a Case of Presumed Diverticular Hemorrhage

    Directory of Open Access Journals (Sweden)

    Nonthalee Pausawasdi

    2011-02-01

    Full Text Available Many patients with lower gastrointestinal bleeding do not have an identifiable source of bleeding at colonoscopy. A significant percentage of these patients will have recurrent bleeding. In many patients, the presence of multiple diverticula leads to a diagnosis of presumed diverticular bleeding. Current treatment options include therapeutic endoscopy, angiography, or surgical resection, all of which depend on the identification of the diverticular source of bleeding. This report describes a case of recurrent bleeding in an elderly patient with diverticula but no identifiable source treated successfully with barium impaction therapy. This therapeutic modality does not depend on the identification of the bleeding diverticular lesion and was well tolerated by our 86-year-old patient.

  8. Water enema CT examination of rectum cancer by reduced amount of water

    International Nuclear Information System (INIS)

    Palko, A.; Gyulai, Cs.; Fedinecz, N.; Balogh, A.; Nagy, F.

    2000-01-01

    To define whether volume of water, administered during water enema CT (WE-CT) for local staging of rectal cancer, may be reduced without compromising the diagnostic value of the examination. Materials and Methods: 29 patients with rectum cancer underwent preoperative WE-CT. Contrast-enhanced CT (equilibrium phase) measurements were performed after i.v. injection of smooth muscle relaxant and rectal administration of 400 - 500 ml lukewarm tap water. Quality of the obtained scans was evaluated and the images were analyzed for depth of tumor invasion. Results of the CT examinations were compared to findings at surgery. Results: Despite reduced dose of water enema, 19/29 examinations were of excellent quality, 6/29 good, and 4/29 poor, but still diagnostic. We achieved sensitivity (90.1), specificity (70.1) and accuracy (86.2) in differentiating tumors confined to the bowel wall from those extending beyond it. Conclusion: Large volume of water enema administered during CT examination of the rectum may cause complaints and increases the risk of complications. Our results prove that using lower amount of water does not impair the quality of examination and accuracy of local staging of rectum carcinomas. (orig.) [de

  9. Enema abuse by mothers of children presenting to the emergency ...

    African Journals Online (AJOL)

    Enema is largely used and widely abused in our community for various ailments including fever, constipation; abdominal pains vomiting and even diarrhoea. Objectives: To describe the abuse of enema at home in the Calabar area, and the associated findings among children who received enema. Method: Children ...

  10. Use of mucolytic agents and guaran HEPART (HP-7000) for the detection of mucosal villi in double contrast barium studies of the small intestine

    International Nuclear Information System (INIS)

    Desaga, J.F.

    1987-01-01

    It was the aim of this study to enhance the visualisation of mucosal villi by double contrast barium studies of the small bowel. Prior to the radiological examination a 2-day pretreatment with the mucolytic agents acetylcysteine or carbocisteine was effected. Double contrast studies were performed with a high-molecular fraction of guaran HEPART (HP-7000), a hydrocolloidal isolated from the seed endosperm of C. tetragonolobus added into contrast-medium and distention medium. Compared to double contrast studies without mucolytic therapy, this procedure results in a better transparency and demonstration of the mucosal villi shown by a granular pattern in the radiographs. High quality visualisation of intestinal villi was achieved in all patients studied. A 2-day pretreatment with carbocisteine or acetylcysteine and the use of guaran in the double contrast barium study of the small bowel results in a greatly enhanced visualisation of mucosal villi. (orig.) [de

  11. Gastrointestinal tract wall visualization and distention during abdominal and pelvic multidetector CT with a neutral barium sulphate suspension: comparison with positive barium sulphate suspension and with water.

    Science.gov (United States)

    Oliva, M R; Erturk, S M; Ichikawa, T; Rocha, T; Ros, P R; Silverman, S G; Mortele, K J

    2012-01-01

    When examining patients with contrast-enhanced multidetector-row CT, we determined if the stomach and small bowel were visualized and distended better with a neutral barium sulphate suspension than with positive barium sulphate suspension or water. After obtaining approval from our institutional review board, 156 patients (women: 84; mean age: 54 yrs) with no history of gastrointestinal tract disease were randomized prospectively to receive orally either 900 ml of neutral (0.1% w/v) barium sulphate suspension (n = 53), 900 ml of positive (2.1% w/v) barium sulphate suspension (n = 53), or 900 ml of water (n = 50), prior to undergoing contrast-enhanced abdominal and pelvic multidetector-row CT. Two independent radiologists evaluated the stomach, and small bowel, for luminal distension and wall visualization, using a five point scale. Results were compared using Kruskal-Wallis and Mann-Whitney U tests. The walls of the stomach, and small bowel were visualized better in patients who were administered neutral barium sulphate suspension than those who were administered either positive barium sulphate suspension (p barium sulphate suspension, the stomach and small bowel were distended better compared to patients administered water (p barium sulphate suspension (p contrast-enhanced abdominal and pelvic multidetector-row CT, orally administered neutral barium sulphate suspension allows the gastrointestinal tract to be visualized and distended better than either positive barium sulphate suspension, or water.

  12. An experimental study on barium peritonitis in rats

    International Nuclear Information System (INIS)

    Kang, Heung Sik; Han, Man Chung; Kim, Chu Wan

    1985-01-01

    Barium sulfate is universally used contrast media in gastrointestinal roentgenology, and spillage of barium into peritoneal cavity can occur. The references on effect of barium sulfate in the peritoneal cavity have been scattered and the results are varied. In 80 rats, body weight of 130 gm to 150 gm, sterile pure barium, sterile commercial barium, intestinal content, and mixed pure barium and intestinal content were experimentally injected into the peritoneal cavity. Consecutive weekly laparotomy and microscopic examination were done for 4 weeks. The results are as followings: 1. Mind inflammatory reaction and mild adhesion after sterile pure barium injection. 2. Mild inflammatory reaction and moderate adhesion after sterile commercial barium injection. 3. Acute peritonitis and abscess formation after intestinal content injection. 4. High mortality due to severe acute peritonitis, and severe adhesion in survivors after injection of both pure barium and intestinal content.

  13. Gastrointestinal fistula

    Science.gov (United States)

    ... to look in the stomach or small bowel Barium enema to look in the colon CT scan of the abdomen to look for fistulas between loops of the intestines or areas of infection Fistulogram, in which contrast dye is injected into the opening of the ...

  14. Extreme hyperphosphatemia and hypocalcemic coma associated with phosphate enema.

    Science.gov (United States)

    Hsu, Heng Jung; Wu, Mai-Szu

    2008-01-01

    Fleet enema (sodium phosphate, C.B. Fleet Co., Inc., Lynchburg, Virginia) is widely used for bowel preparation or constipation relief in the hospital and over the counter. The potential risks, including hyperphosphatemia and hypocalcemic coma should be kept in mind of primary care physician. The patients with older age, bowel obstruction, small intestinal disorders, poor gut motility, and renal disease are contraindicated or should be administered with caution. We present a patient with old age and chronic renal failure who developed severe hyperphosphatemia and hypocalcemic tetany with coma after sodium phosphate enema. We recommend the use of alternative enema preparations, such as simple tap water or saline solution enemas, which can prevent fatal complications in high risk patients.

  15. Early diagnosis and screening for colorectal cancer

    International Nuclear Information System (INIS)

    Laufer, I.

    1986-01-01

    The barium enema has been a neglected tool in the diagnosis of early colon cancer. With appropriate attention to technical detail, the double contrast enema is capable of detecting the smallest malignant and pre-malignant lesions. Many of these early colon cancers are found in asymptomatic patients and these lesions are curable. The goal of a screening program should be to identify by history or by fecal occult blood testing patients at high risk for the development of colon cancer. These patients should be examined by high-quality double contrast enema in the search for these potentially lethal but curable lesions. In addition, we believe that any patient undergoing radiologic examination of the colon for whatever reason, should receive an examination of adequate quality to rule out an early colon cancer. (Author)

  16. Examination of the gastrointestinal tract using the tussian X-ray contrast substance BAR-VIPS based on barium sulfate

    International Nuclear Information System (INIS)

    Ratobyl'skij, G.V.; Kaluzhskij, A.A.

    1997-01-01

    Results of X-ray studies of gastrointestinal tract using domestic X-ray contrast preparation based on barium sulfate BAR-VIPS developed by VIPS-MED company (t. Fryazino, Moscow region). Testing of the preparation has shown that BAR-VIPS permits to diagnose every pathological changes in esophagus, stomach, rectum, small intestine as well as to diagnose successfully large intestine diseases

  17. Iopamidol as an oral contrast media for computed tomography: a taste comparison to iohexol, diatrizoate sodium, and barium sulfate.

    Science.gov (United States)

    Rogers, Douglas; Sheth, Chandni; Eisenmenger, Laura; Mignogna, Eugene; Winter, Thomas

    2017-12-01

    The objective of this study is to compare the palatability of iopamidol and iohexol. This was a blinded and randomized trial in which fifty healthy subjects taste tested iopamidol (Isovue, Bracco Diagnostics), iohexol (Omnipaque, GE Healthcare), diatrizoate meglumine and diatrizoate sodium solution (Gastrografin, Bracco Diagnostics), and barium sulfate suspension 2.1% w/v, 2.0% w/w (READI-CAT2, E-Z-EM). Participants scored palatability on a continuous scale from 0 to 40 (0 = intolerable, 10 = unpleasant but tolerable, 20 = neutral, 30 = kind of like, 40 = strongly like). Mean scores (SD/SEM) for the contrast agents (n = 50) were iopamidol = 21.0 (8.4/1.2); iohexol = 21.8 (7.1/1.0); Gastrografin = 16.8 (9.6/1.4); and barium = 23.7 (9.1/1.3). One-way ANOVA equality of means test shows rejection of the hypothesis that the means are equal (F* = 6.550, p = .000). Post hoc testing demonstrates Gastrografin to be significantly less preferred to barium (p = .000) and iohexol (p = .012). No difference was found between iopamidol and iohexol (p = .959). One-way ANOVA equality of means test of just iopamidol, iohexol, and barium does not reject the hypothesis that means are equal (F* = 1.778 and p = .174). There is no significant difference in palatability between iopamidol and iohexol, supporting the use of iopamidol as a viable alternative to iohexol as an oral contrast agent.

  18. Minimal preparation computed tomography instead of barium enema/colonoscopy for suspected colon cancer in frail elderly patients: an outcome analysis study

    Energy Technology Data Exchange (ETDEWEB)

    Kealey, S.M.; Dodd, J.D.; MacEneaney, P.M.; Gibney, R.G.; Malone, D.E. E-mail: d.malone@st-vincents.ie

    2004-01-01

    .18 [0.43], negative predictive value 0.97 [0.96], positive likelihood ratio result 1.6 [5.63], negative likelihood ratio result 0.27 [0.29], kappa 0.31 [0.43]. Tumour prevalence was 12%. A graph of conditional probabilities was generated and analysed. A variety of unsuspected pathology was also found in this series of patients. CONCLUSIONS: MPCT should be double-reported, at least initially. 'Possible' lesions should be ignored. Analysis of the graph of conditional probability applied to a group of frail, elderly patients with a high mortality from all causes (33% in our study) suggests: (1) if MPCT suggests definite or probable carcinoma, regardless of the pre-test probability, the post-test probability is high enough to warrant further action, (2) frail, elderly patients with a low pre-test probability for CRC and a negative MPCT should not have further investigation, (3) frail, elderly patients with a higher pre-test probability of CRC (such as those presenting with rectal bleeding) and a negative MPCT should have either double contrast barium enema (DCBE) or colonoscopy as further investigations or be followed clinically for 3-6 months. MPCT was acceptable to patients and clinicians and may reveal significant extra-colonic pathology.

  19. Primary non-Hodgkin lymphoma of the cecum. A case report

    International Nuclear Information System (INIS)

    Kropivnik, M.; Jamar, B.; Cernelc, B.

    2002-01-01

    Background. Primary lymphoma of the colon is rare, constituting 0.4% of primary colonic malignancies and usually involves cecum or rectum. The aim of this paper is to present the role and the importance of double contrast barium enema (DCBE) in the diagnostic process. Case report. A 77 years old male was admitted because of suspected inflammation in the area of total endoprosthesis of the left hip, inserted ten years before. Listeria monocytogenes was isolated from the aspirate and the patient treated with antibiotics. Twenty years ago the patient underwent nephrectomy because of hypernephroma of left kidney. At the time of admission he had sideropenic anaemia and he was febrile. Conclusion. The patient underwent many diagnostic procedures: ultrasound (US), computed tomography (CT), double contrast barium enema, which showed a tumour in the cecum, small bowel follow-through and scintigraphy. The diagnosis of primary non-Hodgkin lymphoma was established by histology after biopsy at colonoscopy. (author)

  20. Gluten content of barium sulfate suspensions used for barium swallows in patients with celiac disease.

    Science.gov (United States)

    Chiu, Jennifer G; Shin, Yoona; Patel, Priti N; Mangione, Robert A

    2014-01-01

    To determine the availability and accuracy of information provided by hospitals, imaging centers, and manufacturers regarding gluten in barium sulfate suspensions. A total of 105 facilities were contacted via telephone to determine the gluten content of the contrast media used in those facilities. Manufacturers were contacted and their Web sites reviewed to determine the gluten content of their barium products. Thirty-nine percent of the hospitals and 52% of the imaging centers were not aware of the gluten content of the contrast media they used. Twenty-nine-and-a-half percent of the respondents provided the correct gluten content. The manufacturers noted that 5 products were tested and confirmed gluten free, 1 product was not tested but described as gluten free, 1 product's gluten content depended upon its flavor, and 1 product was reported to contain gluten. Clinicians caring for patients with celiac disease or patients who choose to restrict their gluten consumption must ensure that the barium sulfate suspension ingested is gluten free. It can be difficult to determine the gluten content of barium sulfate, as a majority of radiology departments and imaging centers did not know whether the product they use is gluten free. Educating staff members and improving product labeling would benefit the quality of care provided to patients with celiac disease.

  1. SYMPTOMS AND DIAGNOSIS OF HIRSCHSPRUNG’S DISEASE

    Directory of Open Access Journals (Sweden)

    Putu Ayu Ines Lassiyani Surya

    2014-02-01

    Full Text Available Hirschsprung disease is a disease that attacks the human digestive system, mainly in the largeintestine (colon. In this disease, found enlargement of the colon (megacolon, due to the absenceof ganglion cells in the distal intestine. Hirschsprung disease often affects neonates and evenchildren, are often characterized by delays in spending the first meconium, bilious vomiting,abdominal distension. Methods diagnois do for Hirschsprung's disease was confirmed by biopsy,barium enema or contrast enema, and anorectal manometry. Early diagnosis is crucial to conductrapid and appropriate treatment and to prevent complications.

  2. Thermal injury of the colon due to colostomy irrigation

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, F.R.; Ott, D.J.; Gelfand, D.W.

    1981-07-15

    A case of thermal burn and stricture of the colon following colostomy irrigation with hot water is described. The initial radiographic features on barium enema simulated nonspecific segmental colitis. Colonic stricture and enterolith formation developed subsequently. This case emphasizes that care should be taken in preparing irrigating and barium enema solutions.

  3. Thermal injury of the colon due to colostomy irrigation

    International Nuclear Information System (INIS)

    Jackson, F.R.; Ott, D.J.; Gelfand, D.W.

    1981-01-01

    A case of thermal burn and stricture of the colon following colostomy irrigation with hot water is described. The initial radiographic features on barium enema simulated nonspecific segmental colitis. Colonic stricture and enterolith formation developed subsequently. This case emphasizes that care should be taken in preparing irrigating and barium enema solutions. (orig.)

  4. Clinical application of entire gastrointestinal barium meal combined with multi-temporal abdominal films in patients with intestinal neuronal dysplasia type B.

    Science.gov (United States)

    Li, Xiao-Yun; Li, Xiao-Gang; Du, Ming-Guo; Chen, Zhi-Dan; Tao, Zheng-Gui; Liao, Xiao-Feng

    2013-01-01

    To report and evaluate the application of entire gastrointestinal barium meal combined with multi-temporal abdominal films in the diagnosis of patients with intestinal neuronal dysplasia type B (IND type B). Thirty-six patients with symptoms of long-standing constipation were enrolled in this study. The study took place at the Department of General Surgery, Xiangyang Central Hospital, Hubei Province, China from July 2007 to October 2012. All of them had already been subjected to the tests of barium enema and anorectal manometry and were suspected to be IND type B, but were not confirmed by mucous membrane acetylcholinesterase determination. All underwent the entire gastrointestinal barium meal combined with multi-temporal abdominal films. The data was collected and then analyzed retrospectively. After entire gastrointestinal barium meal combined with multi-temporal abdominal films, 30 out of 36 cases in this group were diagnosed with intestinal neuronal diseases, and then were treated with appropriate surgical treatment. The postoperative pathological diagnosis was IND type B. The other 6 patients in this group still could not be diagnosed explicitly after the test; thus, we treated them with conservative treatment. Entire gastrointestinal barium meal combined with multi-temporal abdominal films has the advantage of being able to test the gastrointestinal transfer capabilities and to find physiological and pathological changes simultaneously. It could provide important proof for the diagnosis of patients with intestinal neuronal dysplasia type B.

  5. Effect of rectal enemas on rectal dosimetric parameters during high-dose-rate vaginal cuff brachytherapy. A prospective trial

    International Nuclear Information System (INIS)

    Sabater, Sebastia; Andres, Ignacio; Sevillano, Marimar; Berenguer, Roberto; Aguayo, Manuel; Villas, Maria Victoria; Gascon, Marina; Arenas, Meritxell; Rovirosa, Angeles; Camacho-Lopez, Cristina

    2016-01-01

    To evaluate the effects of rectal enemas on rectal doses during postoperative high-dose-rate (HDR) vaginal cuff brachytherapy (VCB). This prospective trial included 59 patients. Two rectal cleansing enemas were self-administered before the second fraction, and fraction 1 was considered the basal status. Dose-volume histogram (DVH) values were generated for the rectum and correlated with rectal volume variation. Statistical analyses used paired and unpaired t-tests. Despite a significant 15 % reduction in mean rectal volume (44.07 vs. 52.15 cc, p = 0.0018), 35.6 % of patients had larger rectums after rectal enemas. No significant rectal enema-related DVH differences were observed compared to the basal data. Although not statistically significant, rectal cleansing-associated increases in mean rectal DVH values were observed: D 0.1 cc : 6.6 vs. 7.21 Gy; D 1 cc : 5.35 vs. 5.52 Gy; D 2 cc : 4.67 vs. 4.72 Gy, before and after rectal cleaning, respectively (where D x cc is the dose to the most exposed x cm 3 ). No differences were observed in DVH parameters according to rectal volume increase or decrease after the enema. Patients whose rectal volume increased also had significantly larger DVH parameters, except for D 5 % , D 25 % , and D 50 % . In contrast, in patients whose rectal volume decreased, significance was only seen for D 25 % and D 50 % (D x % dose covering x % of the volume). In the latter patients, nonsignificant reductions in D 2 cc , D 5 cc and V 5 Gy (volume receiving at least 5 Gy) were observed. The current rectal enemas protocol was ineffective in significantly modifying rectal DVH parameters for HDR-VCB. (orig.) [de

  6. Effects of Barium Concentration on Oropharyngeal Swallow Timing Measures

    OpenAIRE

    Stokely, Shauna L.; Molfenter, Sonja M.; Steele, Catriona M.

    2013-01-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between “thin” (40 % w/v concentration) and “ultrathin” (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; ...

  7. Coffee Enema for Preparation for Small Bowel Video Capsule Endoscopy: A Pilot Study

    Science.gov (United States)

    Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck; Ryu, Ho Sang

    2014-01-01

    Coffee enemas are believed to cause dilatation of bile ducts and excretion of bile through the colon wall. Proponents of coffee enemas claim that the cafestol palmitate in coffee enhances the activity of glutathione S-transferase, an enzyme that stimulates bile excretion. During video capsule endoscopy (VCE), excreted bile is one of the causes of poor preparation of the small bowel. This study aimed to evaluate the feasibility and effect of coffee enema for preparation of the small bowel during VCE. In this pilot study, 17 of 34 patients were assigned to the coffee enema plus polyethylene glycol (PEG) 2 L ingestion group, whereas the 17 remaining control patients received 2 L of PEG only. The quality of bowel preparation was evaluated in the two patient groups. Bowel preparations in the proximal segments of small bowel were not differ between two groups. In the mid and distal segments of the small intestine, bowel preparations tend to be better in patients who received coffee enemas plus PEG than in patients who received PEG only. The coffee enema group did not experience any complications or side effects. Coffee enemas may be a feasible option, and there were no clinically significant adverse events related to coffee enemas. More prospective randomized studies are warranted to improve small bowel preparation for VCE. PMID:25136541

  8. Left-colon antegrade continence enema (LACE) procedure for fecal incontinence.

    Science.gov (United States)

    Churchill, Bernard M; De Ugarte, Daniel A; Atkinson, James B

    2003-12-01

    Antegrade continence enemas (ACE) are an efficacious therapeutic option for patients with fecal incontinence. The authors review their institution's experience with a variation of the Monti-Malone ACE procedure using the left colon as a source of an intestinal conduit and enema reservoir. From 2000 to 2002, 18 patients with fecal incontinence or intractable constipation underwent left-colon ACE (LACE) procedure. Concomitant Mitrofanoff appendicovesicostomy was performed in 15 patients and bladder augmentation in 9. The majority of patients had neural tube defects. A segment of left colon was tubularized, tunneled into the muscular wall of the distal colon, and exteriorized through the left upper quadrant or midabdomen. Stomal catherization and enema installation were started one month postoperatively. Fifteen patients (83%) achieved fecal continence, 2 remain incontinent of stool, and 1 experienced stomal closure (mean follow-up was 24 +/- 9 months). Two patients had stomal stenosis that required revision. The mean enema volume in patient's achieving continence was 360 +/- 216 mL, and the mean transit time was 18 +/- 12 minutes. LACE is an efficacious procedure for fecal incontinence that can be performed safely at the time of major urologic reconstruction. Administration of enemas into the left colon has several physiologic advantages that result in predictable bowel evacuation.

  9. Anastomotic stenosis of the descending colon caused by barium granuloma formation following barium peritonitis: report of a case.

    Science.gov (United States)

    Kitajima, Toshihiro; Tomizawa, Kenji; Hanaoka, Yutaka; Toda, Shigeo; Matoba, Shuichiro; Kuroyanagi, Hiroya; Oota, Yasunori

    2014-11-01

    Anastomotic stricture reportedly often recurs following barium peritonitis, regardless of whether the anastomotic diameter is initially sufficient. However, the causes of repetitive stricture have not been clarified. We report a case that suggests the pathophysiology of recurrent anastomotic strictures following barium peritonitis. The patient was a 39-year-old Japanese man with idiopathic perforation of the descending colon after undergoing an upper gastrointestinal barium contrast study. After emergency peritoneal lavage and diverting colostomy, created using the perforated region, the patient recovered uneventfully and 3 months later, the colostomy was closed and the perforated colon was resected. However, 7 months after colostomy closure, abdominal distention gradually developed, and colonoscopy revealed an anastomotic stricture. The patient was referred to our hospital where he underwent resection of the anastomotic stricture. The surgical specimen exhibited barium granulomas not only in the subserosa of the entire specimen, but also in the submucosa and lamina propria localized in the anastomotic site. These findings suggest that barium was embedded in the submucosa and lamina propria with manipulation of the stapled anastomosis and that the barium trapped in the anastomotic site caused persistent inflammation, resulting in an anastomotic stricture.

  10. Comparative evaluation of the fecal-tagging quality in CT colonography: barium vs. iodinated oral contrast agent.

    Science.gov (United States)

    Nagata, Koichi; Singh, Anand Kumar; Sangwaiya, Minal Jagtiani; Näppi, Janne; Zalis, Michael E; Cai, Wenli; Yoshida, Hiroyuki

    2009-11-01

    The purpose of this evaluation was to compare the tagging quality of a barium-based regimen with that of iodine-based regimens for computed tomographic (CT) colonography. Tagging quality was assessed retrospectively in three different types of fecal-tagging CT colonographic cases: 24 barium-based cases, 22 nonionic iodine-based cases, and 24 ionic iodine-based cases. For the purpose of evaluation, the large intestine was divided into six segments, and the tagging homogeneity of a total of 420 segments (70 patients) was graded by three blinded readers from 0 (heterogeneous) to 4 (homogeneous). For barium-based cases, the average score for the three readers was 2.4, whereas it was 3.4 for nonionic iodine and 3.6 for ionic iodine. The percentages of segments that were assigned scores of 4 (excellent tagging [100%]) were 11.6%, 61.9%, and 72.9% for the barium-based, nonionic iodine-based, and ionic iodine-based regimens, respectively. The homogeneity scores of iodine-based fecal-tagging regimens were significantly higher than those of the barium-based fecal-tagging regimen (P barium-based regimen (P barium-based fecal-tagging regimen. Iodine-based fecal-tagging regimens can provide an appropriate method for use in nonlaxative or minimum-laxative CT colonography.

  11. Effects of barium concentration on oropharyngeal swallow timing measures.

    Science.gov (United States)

    Stokely, Shauna L; Molfenter, Sonja M; Steele, Catriona M

    2014-02-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

  12. The Quebec Association of Gastroenterology Position Paper on Colorectal Cancer Screening - 2003

    Directory of Open Access Journals (Sweden)

    AN Barkun

    2004-01-01

    Full Text Available Colorectal cancer is a leading cause of death and the third most common cancer in Canada. Evidence suggests that screening can reduce mortality rates and the cost effectiveness of a program compares favourably with initiatives for breast and cervical cancer. The objectives of the Association des gastro-entérologues du Québec Task Force were to determine the need for a policy on screening for colorectal cancer in Quebec, to evaluate the testing methods available and to propose one or more of these alternatives as part of a formal screening program, if indicated. Fecal occult blood testing (FOBT, endoscopy (including sigmoidoscopy and colonoscopy, barium enema and virtual colonoscopy were considered. Although most clinical efficacy data are available for FOBT and sigmoidoscopy, there are limitations to programs based on these strategies. FOBT has a high false positive rate and a low detection yield, and even a combination of these strategies will miss 24% of cancers. Colonoscopy is the best strategy to both detect and remove polyps and to diagnose colorectal cancer, with double contrast barium enema also being a sensitive detection method. The Task Force recommended the establishment, in Quebec, of a screening program with five- to 10-yearly double contrast barium enema or 10-yearly colonoscopy for individuals aged 50 years or older at low risk. The program should include outcome monitoring, public and professional education to increase awareness and promote compliance, and central coordination with other provincial programs. The program should be evaluated; specific billing codes for screening for colorectal cancer would help facilitate this. Formal feasibility, effectiveness and cost-effectiveness studies in Quebec are now warranted.

  13. Lower rectal cancer. Preoperative staging with CT air enema technique

    International Nuclear Information System (INIS)

    Kanazawa, Amane; Fujii, Shouichi; Iwata, Seiichirou

    2009-01-01

    Preoperative assessment of rectal cancer wall invasion is an important indication of the need for lateral side wall dissection. The purpose of this study was to determine the accuracy rates and clinical usefulness of air-enema CT in preoperative staging of lower rectal cancer. A total of 88 patients diagnosed with lower rectal cancer were examined with an air-enema CT preoperatively and had surgical resection performed. One group was T1-T2 while the other was T3-T4. Forty-two patients were T1-T2, and 46 patients were T3-T4. In univariate and multivariate analysis, irregularities of the rectal wall and spiculated appearance of the rectal wall were significant predictive factors in T3-T4. In patients with air-enema CT findings of rectal wall irregularities and speculated appearance, the accuracy rate for detecting T3-T4 was 85.2-86.45 percent. These results show that air-enema CT is useful for determining the preoperative staging of lower rectal cancer and indication of the need for lateral side wall dissection. (author)

  14. Small bowel volvulus in children

    International Nuclear Information System (INIS)

    Siegel, M.J.; Shackelford, G.D.; McAlister, W.H.

    1980-01-01

    Two children with small bowel volvulus diagnosed on barium enema examination are reported. In one patient the volvulus was associated with malrotation and in the other patient there was a post-operative peritoneal adhesion. In both cases the diagnosis was based on beaking of the head of the barium column at the site of volvulus. Radiographic demonstration of a beak sign in the small bowel on barium enema examination should suggest a diagnosis of small bowel volvulus, and indicates the need for immediate surgery. (orig.) [de

  15. Virtual colonoscopy training and accreditation: a national survey of radiologist experience and attitudes in the UK

    International Nuclear Information System (INIS)

    Burling, D.; Moore, A.; Taylor, S.; La Porte, S.; Marshall, M.

    2007-01-01

    Aim: Expert consensus recommends directed training and possibly in the future, formal accreditation before independent virtual colonoscopy (VC) reporting. We surveyed radiologists' experience of VC training, compared with barium enema, and assessed attitudes towards accreditation. Materials and methods: A questionnaire was sent to 78 consultant radiologists from 72 centres (65 National Health Service hospitals; seven independent primary screening centres) offering a VC service. Results: Fifty-four (69%) eligible radiologists responded. They had interpreted 18,152 examinations (range 3-1500) in total versus 232,350 (13 times more) barium enemas. Twenty-two (41%) deemed their VC training as inadequate [including five (45%) of screening centre radiologists], and only 14 (26%) had attended a training workshop due to lack of availability (54%) or financial/study leave constraints (24%). Eleven (20%) radiologists routinely double-reported VC examinations versus 37 (69%) barium enemas, yet 21 (39%) considered requirements for VC training were greater than barium enema. Thirty-eight (70%) favoured accreditation beyond internal audit for VC versus 15(28%) for barium enema. Of these 38, seven (18%) favoured 'one-off,' and 18 (47%) periodic testing, with 16 (42%) favouring external audit alone or in combination with testing. Overall, 42 (78%) considered specific accreditation for reporting screening examinations appropriate and 45 (83%) respondents preferred a national radiological organization to regulate such a scheme. Conclusion: There is wide variability in reporting experience and recommendations for VC training have not been widely adopted, in part due to limited access to dedicated workshops. UK radiologists are generally in favour of VC accreditation, governed by a national radiology organization

  16. Contrast Materials

    Science.gov (United States)

    ... is mixed with water before administration liquid paste tablet When iodine-based and barium-sulfate contrast materials ... for patients with kidney failure or allergies to MRI and/or computed tomography (CT) contrast material. Microbubble ...

  17. ORIGINAL ARTICLE ORIG ORIG Comparison of barium and ...

    African Journals Online (AJOL)

    SA JOURNAL OF RADIOLOGY • June 2007. ORIG. Abstract. Background. Simulation of patients with carcinoma of the oesophagus using radio-opaque contrast is a standard step in treatment planning prior to delivering radiation therapy. Various contrast mediums such as barium, gastrograffin and hexabrix have been used ...

  18. The impact of high-density barium use in double contrast radiographic methods for gastric cancer screening in Niigata, Japan.

    Science.gov (United States)

    Wakai, Shizuko; Tanabe, Naohito; Suzuki, Hiroshi

    2005-04-01

    Use of high-density barium (= or > 180 w/v%) has been widely spread in community-based mass screening for gastric cancer in Japan. However, the impact on outcomes of the screening has not been fully evaluated. Then, we investigated the advantage of high-density barium use by comparing the outcomes between a period with high-density barium and that with low-density barium (barium decreases the positive finding rate in initial mass screening x-ray examinations by 12% (odds ratio, 0.88; 95% confidence interval, 0.86 - 0.90) and increase the gastric cancer detection rate by diagnostic examination by 15% (odds ratio, 1.15; 95% confidence interval, 1.01-1.31). We conclude that introduction of high-density barium has improved the efficiency of mass screening for gastric cancer by decreasing unnecessary diagnostic examinations and reducing the total personal and public health costs. Thus, nationwide use of high-density barium is recommended for mass gastric cancer screening in Japan.

  19. Glycerin enemas and suppositories in premature infants: a meta-analysis.

    Science.gov (United States)

    Livingston, Michael H; Shawyer, Anna C; Rosenbaum, Peter L; Williams, Connie; Jones, Sarah A; Walton, J Mark

    2015-06-01

    Premature infants are often given glycerin enemas or suppositories to facilitate meconium evacuation and transition to enteral feeding. The purpose of this study was to assess the available evidence for this treatment strategy. We conducted a systematic search of Medline, Embase, Central, and trial registries for randomized controlled trials of premature infants treated with glycerin enemas or suppositories. Data were extracted in duplicate and meta-analyzed using a random effects model. We identified 185 premature infants treated prophylactically with glycerin enemas in one trial (n = 81) and suppositories in two other trials (n = 104). All infants were less than 32 weeks gestation and had no congenital malformations. Treatment was associated with earlier initiation of stooling in one trial (2 vs 4 days, P = .02) and a trend towards earlier meconium evacuation in another (6.5 vs 9 days, P = .11). Meta-analysis demonstrated no effect on transition to enteral feeding (0.7 days faster, P = .43) or mortality (P = 0.50). There were no reports of rectal bleeding or perforation but there was a trend towards increased risk of necrotizing enterocolitis with glycerin enemas or suppositories (risk ratio = 2.72, P = .13). These three trials are underpowered and affected by one or more major methodological issues. As a result, the quality of evidence is low to very low. Three other trials are underway. The evidence for the use glycerin enemas or suppositories in premature infants in inconclusive. Meta-analyzed data suggest that treatment may be associated with increased risk of necrotizing enterocolitis. Careful monitoring of ongoing trials is required. Copyright © 2015 by the American Academy of Pediatrics.

  20. Functionalized synchrotron in-line phase-contrast computed tomography: a novel approach for simultaneous quantification of structural alterations and localization of barium-labelled alveolar macrophages within mouse lung samples

    Energy Technology Data Exchange (ETDEWEB)

    Dullin, Christian, E-mail: christian.dullin@med.uni-goettingen.de [University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Monego, Simeone dal [Cluster in Biomedicine, AREA Science Park Basovizza, Trieste (Italy); Larsson, Emanuel [Elettra Sincrotrone Trieste, Strada Statale 14, km 163.5 in AREA Science Park, 34149 Basovizza (Trieste) (Italy); University of Trieste, Trieste (Italy); Linköping University, SE-581 83 Linkoeping (Sweden); Mohammadi, Sara [Elettra Sincrotrone Trieste, Strada Statale 14, km 163.5 in AREA Science Park, 34149 Basovizza (Trieste) (Italy); Krenkel, Martin [University of Göttingen, Göttingen (Germany); Garrovo, Chiara; Biffi, Stefania [IRCCS Burlo Garofolo, Trieste (Italy); Lorenzon, Andrea [Cluster in Biomedicine, AREA Science Park Basovizza, Trieste (Italy); Markus, Andrea [University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Napp, Joanna [University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Max Planck Institute for Experimental Medicine, Hermann-Rein-Strasse 3, 37075 Göttingen (Germany); University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Salditt, Tim [University of Göttingen, Göttingen (Germany); Accardo, Agostino [University of Trieste, Trieste (Italy); Alves, Frauke [University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Max Planck Institute for Experimental Medicine, Hermann-Rein-Strasse 3, 37075 Göttingen (Germany); University Medical Center Göttingen, Robert Koch Strasse 40, 37075 Göttingen (Germany); Tromba, Giuliana [Elettra Sincrotrone Trieste, Strada Statale 14, km 163.5 in AREA Science Park, 34149 Basovizza (Trieste) (Italy)

    2015-01-01

    This study presents an approach to increase the sensitivity of lung computed tomography (CT) imaging by utilizing in-line phase contrast CT in combination with single-distance phase-retrieval algorithms and a dedicated image-processing regime. As demonstrated here, functional CT imaging can be achieved for the assessment of both structural alterations in asthmatic mouse lung tissue and the accumulation pattern of instilled barium-sulfate-labelled macrophages in comparison with healthy controls. Functionalized computed tomography (CT) in combination with labelled cells is virtually non-existent due to the limited sensitivity of X-ray-absorption-based imaging, but would be highly desirable to realise cell tracking studies in entire organisms. In this study we applied in-line free propagation X-ray phase-contrast CT (XPCT) in an allergic asthma mouse model to assess structural changes as well as the biodistribution of barium-labelled macrophages in lung tissue. Alveolar macrophages that were barium-sulfate-loaded and fluorescent-labelled were instilled intratracheally into asthmatic and control mice. Mice were sacrificed after 24 h, lungs were kept in situ, inflated with air and scanned utilizing XPCT at the SYRMEP beamline (Elettra Synchrotron Light Source, Italy). Single-distance phase retrieval was used to generate data sets with ten times greater contrast-to-noise ratio than absorption-based CT (in our setup), thus allowing to depict and quantify structural hallmarks of asthmatic lungs such as reduced air volume, obstruction of airways and increased soft-tissue content. Furthermore, we found a higher concentration as well as a specific accumulation of the barium-labelled macrophages in asthmatic lung tissue. It is believe that XPCT will be beneficial in preclinical asthma research for both the assessment of therapeutic response as well as the analysis of the role of the recruitment of macrophages to inflammatory sites.

  1. The Malone antegrade continence enema for neurogenic and structural fecal incontinence and constipation.

    Science.gov (United States)

    Koyle, M A; Kaji, D M; Duque, M; Wild, J; Galansky, S H

    1995-08-01

    Problems of fecal elimination are commonly encountered by the pediatric urologist and surgeon. The Malone antegrade continence enema has been described as a means to administer a large volume enema via a continent catheterizable appendicocecostomy, resulting in reliable fecal elimination. Of 22 patients undergoing this procedure 16 reported total continence 4 months or longer after surgery. Complications are relatively minor and tap water appears to be a safe solution for the antegrade continence enema. A nonrefluxing, imbricated appendicocecostomy is preferable to prevent cutaneous fecal or gas leaks.

  2. Patient radiation doses from enteroclysis examinations

    International Nuclear Information System (INIS)

    Hart, D.; Wall, B.F.; Haggett, P.J.; Boardman, P.; Nolan, D.J.

    1994-01-01

    Data relating to patient dose have been acquired for enteroclysis examinations (small bowel enemas) performed at the John Radcliffe Hospital, Oxford, on 23 adult patients. Dose-area products, fluoroscopy times and the number of radiographs taken are used to compare the examination procedure at the Hospital with enteroclysis and barium follow-throughs performed elsewhere. The mean dose-area product for the 23 examinations was 6.8 Gy cm 2 and the mean effective dose was estimated to be 1.5 mSv. These doses are intermediate between those arising from barium meals and barium enemas performed in the same room. (author)

  3. A controlled trial of colostomy management by natural evacuation, irrigation and foam enema.

    Science.gov (United States)

    Doran, J; Hardcastle, J D

    1981-10-01

    Twenty patients entered a prospective controlled trial of colostomy management by three techniques--natural evacuation, colostomy irrigation and foam enema. Every patient spent 2 months using each technique. The mean number of colostomy actions weekly was 17 during natural evacuation, 6 during irrigation and 10 with the enema. There was no significant difference in the time taken to manage the colostomy by each technique. Eighteen patients considered that both irrigation and the foam enema improved the quality of their life, and opted to continue with irrigation on completion of the study. There were no major complications during the trial but leakage of foam and an increase in flatus were problems with the foam enema. It is concluded that patients should be made aware of the alternative methods available for colostomy management and be encouraged to use the method of their choice.

  4. Atresia coli in a Japanese black calf diagnosed by a barium sulphate enema contrast radiograph in the standing position: a case report

    International Nuclear Information System (INIS)

    Abouelnasr, K.; Ishii, M.; Inokuma, H.; Kobayashi, Y.; Lee, K.; Yamada, K.

    2012-01-01

    A three day-old Japanese black calf was admitted with a history of abdominal distension and absence of defecation. Dilated loops of the small intestine and hypoplasia of the colon and rectum was observed upon a contrast radiographic examination in the standing position. At necropsy atresia coli with undeveloped rectum and patent anal opening was found. We conclude that a contrast radiograph in the standing position is useful for diagnosing atresia coli in such cases

  5. Perforation and mortality after cleansing enema for acute constipation are not rare but are preventable

    Directory of Open Access Journals (Sweden)

    Niv G

    2013-04-01

    Full Text Available Galia Niv,1 Tamar Grinberg,2 Ram Dickman,3 Nir Wasserberg,4 Yaron Niv1,3 1Risk Management and Quality Assurance, 2Emergency Department, 3Department of Gastroenterology, 4Department of Surgery B, Rabin Medical Center, Beilinson Hospital and Tel Aviv University, Tel Aviv, Israel Objectives: Constipation is a common complaint, frequently treated with cleansing enema. Enemas can be very effective but may cause serious adverse events, such as perforation or metabolic derangement. Our aim was to evaluate the outcome of the use of cleansing enema for acute constipation and to assess adverse events within 30 days of therapy. Methods: We performed a two-phase study: an initial retrospective and descriptive study in 2010, followed by a prospective study after intervention, in 2011. According to the results of the first phase we established guidelines for the treatment of constipation in the Emergency Department and then used these in the second phase. Results: There were 269 and 286 cases of severe constipation in the first and second periods of the study, respectively. In the first study period, only Fleet® Enema was used, and in the second, this was changed to Easy Go enema (free of sodium phosphate. There was a 19.2% decrease in the total use of enema, in the second period of the study (P < 0.0001. Adverse events and especially, the perforation rate and the 30-day mortality in patients with constipation decreased significantly in the second phase: 3 (1.4% versus 0 (P = 0.0001 and 8 (3.9% versus 2 (0.7% (P = 0.0001, for perforation and death in the first and second period of the study, respectively. Conclusion: Enema for the treatment of acute constipation is not without adverse events, especially in the elderly, and should be applied carefully. Perforation, hyperphosphatemia (after Fleet Enema, and sepsis may cause death in up to 4% of cases. Guidelines for the treatment of acute constipation and for enema administration are urgently needed. Keywords

  6. Rectal Fecal Impaction Treatment in Childhood Constipation: Enemas Versus High Doses Oral PEG

    NARCIS (Netherlands)

    Bekkali, Noor-L.-Houda; van den Berg, Maartje-Maria; Dijkgraaf, Marcel G. W.; van Wijk, Michiel P.; Bongers, Marloes E. J.; Liem, Olivia; Benninga, Marc A.

    2009-01-01

    OBJECTIVE: We hypothesized that enemas and polyethylene glycol (PEG) would be equally effective in treating rectal fecal impaction (RFI) but enemas would be less well tolerated and colonic transit time (CTT) would improve during disimpaction. METHODS: Children (4-16 years) with functional

  7. Acute respiratory failure caused by aspiration of high density barium: A case report

    International Nuclear Information System (INIS)

    Park, Ki Soon; Jung, Eun A; Yang, Ik; Lee, Yul; Chung, Soo Young

    1994-01-01

    Accidental aspiration of barium contrast medium during the upper gastrointestinal study can occur in patients with swallowing disorder, especially in the elderly patients. We experienced a case of respiratory failure followed by death within a few hours in 85 year-old patient after barium aspiration

  8. Results of a cooperative study for the evaluation of the barium meal Falibaryt HD

    International Nuclear Information System (INIS)

    Reisinger, W.; Liess, G.; Beckmann, D.; Block, H.G.; Dietze, R.; Grosche, N.; Hall, E.; Lasch, G.; Knoth, H.J.; Kroeger, W.

    1986-01-01

    The diagnostic capabilities of radiologic investigations of the stomach in double contrast can be significantly improved with high-density low-viscosity barium meals. In the GDR the barium meal Falibaryt HD with a barium sulfate content of 215 g per 100 ml suspension has been developed. In nearly 1,000 radiologic investigations of the stomach (81% in relaxation with spasmolytics, 66% without hypotony) all fine structures were well imaged and the preparation therefore is comparable with the best barium meals presently on the market. (author)

  9. Radiation exposure to the patient during X-ray fluoroscopy and radiography

    International Nuclear Information System (INIS)

    Dimov, A.; Vassileva, J.

    2006-01-01

    Full text: The aim of this study is to assess the patient doses received during conventional and digital X-ray radiography, conventional fluoroscopy of the lungs, and one of the highest dose X-ray procedures - contrast examination of the large intestine (Barium enema examination). The measured quantity is Kerma area product (KAP), registered with a clinical dosimeter DRK-1 (Doza, Russia). A total number of 89 patients are included in the study. The Organ doses and Effective doses were assessed using Monte Carlo calculation code (PCXMC 1.4 (Finland). The measurements took place at the following X-ray units: a CGR (Koch and Sterzel) with two working posts - for radiography and fluoroscopy, a Philips Telediagnost (for barium enema) and an Oldelft N800HF Digidelca (for digital radiography of the chest). The typical KAP per procedure at digital radiography, conventional X-ray radiography and fluoroscopy and Barium enema examination are: 17; 95; 928 and 3630 cGy.cm 2 respectively; the average effective doses are: 0.022; 0.053; 0.728 and 8.0 mSv respectively. Doses to the lungs at digital radiography, conventional radiography and fluoroscopy are: 0.066; 0.136 and 2.412 mSv respectively and the dose to the upper and lower large intestine are: 11.7 and 8.6 mSv respectively. Conclusion: The approach used is applicable for assessment of radiation exposure to the patient during X-ray radiography and fluoroscopy. It needs registration of KAP meter readings when this device is installed on the stationary X-ray units

  10. BARIUM RECOVERY PROCESS

    Science.gov (United States)

    Blanco, R.E.

    1959-07-21

    A method of separating barium from nuclear fission products is described. In accordance with the invention, barium may be recovered from an acidic solution of neutron-irradiated fissionable material by carrying ihe barium cut of solution as a sulfate with lead as a carrier and then dissolving the barium-containing precipitate in an aqueous solution of an aliphatic diamine chelating reagent. The barium values together with certain other metallic values present in the diamine solution are then absorbed onto a cation exchange resin and the barium is selectively eluted from the resin bed with concentrated nitric acid.

  11. Improving Quality and Efficiency for Intussusception Management After Successful Enema Reduction.

    Science.gov (United States)

    Raval, Mehul V; Minneci, Peter C; Deans, Katherine J; Kurtovic, Kelli J; Dietrich, Ann; Bates, D Gregory; Rangel, Shawn J; Moss, R Lawrence; Kenney, Brian D

    2015-11-01

    The purpose of this project was to implement a protocol facilitating discharge from the emergency department (ED) after successful radiologic ileocolic intussusception reduction in a pediatric referral center. A multidisciplinary team identified drivers for successful quality improvement including educational brochures, a standardized radiologic report, an observation period in the ER with oral hydration challenges, and follow-up phone calls the day after discharge. Patient outcomes were tracked, and quarterly feedback was provided. Of 80 patients identified over a 24-month period, 34 (42.5%) did not qualify for discharge home due to need for surgical intervention (n = 9), specific radiologic findings (n = 11), need for additional intravenous hydration (n = 4), or other reasons (n = 7). Of 46 patients who qualified for discharge, 30 (65.2%) were successfully sent home from the ED. One patient returned with recurrent symptoms that required repeat enema reduction. Sixteen patients were observed and discharged within 23 hours. Adherence with discharge from the ED improved over time. Discharge from the ED was associated with cost savings and improved net margins at the hospital level for each encounter. A sustainable multidisciplinary quality improvement project to discharge intussusception patients from the ED after air-contrast enema reduction was successfully integrated in a high-volume referral center through education, standardized radiologic reporting, and protocoled follow-up. Copyright © 2015 by the American Academy of Pediatrics.

  12. Effect of mucolytic pretreatment on gastric mucosal coating with barium sulfate in the rat

    International Nuclear Information System (INIS)

    Lindgren, I.; Nevalainen, T.; Maeki, J.; Soederstroem, K.-O.

    1980-01-01

    Freshly prepared isolated rat stomachs were used to examine the adherence of barium sulfate particles to the mucosal surface by scanning electron microscopy. The stomachs were pretreated with sodium bicarbonate alone or in connection with N-acetyl-L-cysteine and then treated with barium sulfate specially designed for double contrast examination of the stomach. The best adhesion of the contrast medium was obtained when the mucosa was pretreated with both the alkaline and mucolytic agent indicating that, for the optimum adherence of the contrast medium, the mucosal surface must be as clean as possible. (Auth.)

  13. Epidermal growth factor enemas for induction of remission in left-sided ulcerative colitis

    Directory of Open Access Journals (Sweden)

    Hugo Nodarse-Cuní

    2013-03-01

    Full Text Available Introduction: ulcerative colitis is a little known chronic inflammatory disease in colonic mucosa. The positive effect of epidermal growth factor was shown in a previous report, with enema use for treatment of mild to moderate left-sided manifestation of the disease. This evidence provided the basis for evaluating the efficacy and safety profile of a viscous solution of this product. Methods: thirty-one patients were randomized to three groups for daily medications during 14 days. Twelve received one 10 mg enema of epidermal growth factor dissolved in 100 mL of viscous solution whereas nine were treated with placebo enema; both groups also received 1.2 g of oral mesalamine per day. The other group included ten patients with 3 g / 100 mL of mesalamine enema. Primary end point was clinical responses after two weeks of treatment, defined as a decreased of, at least three points from baseline, the Disease Activity Index and endoscopic or histological evidences of improvement. Results: remission of disease was observed in all patients in the epidermal growth factor group, and six in both, mesalamine enema and placebo group. All the comparisons between groups showed statistically significant superiority for epidermal growth factor, the only product with significant reduction in disease activity index as well as the presence and intensity of digestive symptoms in patients after treatment. None adverse event was reported. Conclusions: the results agree with previous molecular and clinical evidences, indicating that the epidermal growth factor is effective to reduce disease activity and to induce remission. A new study involving more patients should be conducted to confirm the efficacy of the epidermal growth factor enemas.

  14. The radiographic findings of adult congenital megacolon disease

    International Nuclear Information System (INIS)

    Deng Xiaotao; Yu Jingying; Zhang Yongchun

    2000-01-01

    Objective: To describe the radiographic findings of adult megacolon. Methods: Barium enema examination was performed in 6 patients with megacolon proved by operation. Results: The principal radiographic findings were a markedly dilated colon, the largest diameter was 22 cm, and a narrowed rectum, its length was 3-7 cm; with a cone or funnel shaped transitional segment, it is about 2-6 cm long. Conclusion: The barium enema examination is the most reliable and simple method in diagnosing adult congenital megacolon

  15. Clinical efficacy of a new barium sulfate for abdominal CT

    International Nuclear Information System (INIS)

    Yamada, Tatuya; Kohno, Mitio; Uematsu, Sadao; Nisitani, Hiromu; Tanaka, Takao.

    1988-01-01

    Computed Tomography of the abdomen requires that the intestines are filled with contrast medium so that the gut is not misinterpreted as a pathologic process. Besides, normal structures may be difficult to delimit in patients with scanty intra-abdominal fat. In Japan, up to date, only a single contrast medium has been available for this purpose, Gastrografin and thus identical with the intravasculaly used Urografin or Angiografin. A new Barium Sulfate suspention (Fusimi Seiyaku, Kagawa) for computed tomographic use has been dilute solution (4.77 %) and with suspending agents that prevent a rapid sedimentation of the Barium Sulfate. The aim of this investigation was to compare Gastrografin with a new barium regarding patients tolerance, side effects and diagnostic information. The investigation comprised 146 patients who were reffered for abdominal CT and was carried out by 5 facilities; National Cancer Center, Kobe University, Chiba University, Kyushu University and Juntendo University. Diagnostic information was judged with respect to the filling of the stomach and intestines, the presence of imaging artifacts and finally clinical estimation. Patients tolerance was investigated as regards taste and side effects. Good filling of the stomach and intestines was obtained in this investigation. However, imaging artifacts occured in only a few cases. The imaging artifacts appeared almost exclusively to arise in the boundary layer between the bowel gas and contrast medium, and were most common in the stomach. However, the contrasting effect of this medium did not in itself appear to cause any imaging artifacts. Fushimi's new barium seems to be preffered because of its lesser tendency to arise artifacts and better tendency to make good filling of the stomach and intestines. Moreover, this investigation did not have any side effects. (J.P.N.)

  16. Low-dose CT colonography in children: initial experience, technical feasibility and utility

    International Nuclear Information System (INIS)

    Anupindi, Sudha; Perumpillichira, James; Zalis, Michael E.; Jaramillo, Diego; Israel, Esther J.

    2005-01-01

    CT colonography (CTC) is utilized as a diagnostic tool in the detection of colon polyps and early colorectal cancer in adults. Large studies in the literature, although focused on adult populations, have shown CTC to be a safe, accurate, non-invasive technique. We evaluated the technical feasibility of CTC in children using a low-dose technique. From November 2001 to April 2004 we evaluated eight patients (3-17 years) with non-contrast CTC. Seven of the patients had CTC, followed by standard colonoscopy (SC) the same day; in one patient, CTC followed a failed SC. CTC results were compared to results of SC. The estimated effective dose from each CTC was calculated and compared to that of standard barium enema. CTC results were consistent with those of SC. Sensitivity for polyps 5-10 mm was 100%, and sensitivity for polyps 10 mm and larger was 66.7%. The estimated mean effective dose was 2.17 mSv for CTC, compared to the 5-6 mSv for a standard air-contrast barium enema in a small child. Our initial experience shows CTC in children is well-tolerated, safe, and useful. The procedure can be performed successfully with a low radiation dose, and preliminary results compare well with SC. (orig.)

  17. Topical contrast agents to improve soft-tissue contrast in the upper airway using cone beam CT: a pilot study.

    Science.gov (United States)

    Alsufyani, N A; Noga, M L; Finlay, W H; Major, P W

    2013-01-01

    The purpose of this study is to explore the topical use of radiographic contrast agents to enhance soft-tissue contrast on cone beam CT (CBCT) images. Different barium sulphate concentrations were first tested using an airway phantom. Different methods of barium sulphate application (nasal drops, syringe, spray and sinus wash) were then tested on four volunteers, and nebulized iodine was tested in one volunteer. CBCT images were performed and then assessed subjectively by two examiners for contrast agent uniformity and lack of streak artefact. 25.0% barium sulphate presented adequate viscosity and radiodensity. Barium sulphate administered via nasal drops and sprays showed non-uniform collection at the nostrils, along the inferior and/or middle nasal meatuses and posterior nasal choana. The syringe and sinus wash showed similar results with larger volumes collecting in the naso-oropharynx. Nebulized iodine failed to distribute into the nasal cavity and scarcely collected at the nostrils. All methods of nasal application failed to adequately reach or uniformly coat the nasal cavity beyond the inferior nasal meatuses. The key factors to consider for optimum topical radiographic contrast in the nasal airway are particle size, flow velocity and radio-opacity.

  18. The use of low-osmolar water-soluble contrast in videofluoroscopic swallowing exams.

    Science.gov (United States)

    Harris, Julie A; Bartelt, Detlef; Campion, Molly; Gayler, Bob W; Jones, Bronwyn; Hayes, Andrea; Haynos, Judith; Herbick, Seanne; Kling, Therese; Lingaraj, Arpana; Singer, Michele; Starmer, Heather; Smith, Christine; Webster, Kim

    2013-12-01

    The selection of the contrast agent used during fluoroscopic exams is an important clinical decision. The purpose of this article is to document the usage of a nonionic, water-soluble contrast (iohexol) and barium contrast in adult patients undergoing fluoroscopic exams of the pharynx and/or esophagus and provide clinical indications for the use of each. For 1 year, data were collected on the use of iohexol and barium during fluoroscopic exams. The contrast agent used was selected by the speech language pathologist (SLP) or the radiologist based on the exam's indications. A total of 1,978 fluoroscopic exams were completed in the 12-month period of documentation. Of these exams, 60.6 % were completed for medical reasons and 39.4 % for surgical reasons. Fifty-five percent of the exams were performed jointly by a SLP and a radiologist and 45 % were performed by a radiologist alone. Aspiration was present in 22 % of the exams, vestibular penetration occurred in 38 %, extraluminal leakage of contrast was observed in 4.6 %, and both aspiration and leakage were seen in 1 % of the exams. In cases with aspiration, iohexol was used alone in 8 %, iohexol and barium were both used in 45 %, and barium was used alone in 47 %. In cases with extraluminal leakage, iohexol was used alone in 58 %, iohexol and barium were both used in 31 %, and barium was used alone in 11 %. No adverse effects were seen with the use of iohexol. When barium was used in cases of aspiration and extraluminal leakage, the amount of aspirated barium was small and the extraluminal barium in the instances of leakage was small. Iohexol is a useful screening contrast agent and can safely provide information, and its use reduces the risk of aspiration and the chance of leakage of large amounts of barium.

  19. Functionalized synchrotron in-line phase-contrast computed tomography: a novel approach for simultaneous quantification of structural alterations and localization of barium-labelled alveolar macrophages within mouse lung samples.

    Science.gov (United States)

    Dullin, Christian; dal Monego, Simeone; Larsson, Emanuel; Mohammadi, Sara; Krenkel, Martin; Garrovo, Chiara; Biffi, Stefania; Lorenzon, Andrea; Markus, Andrea; Napp, Joanna; Salditt, Tim; Accardo, Agostino; Alves, Frauke; Tromba, Giuliana

    2015-01-01

    Functionalized computed tomography (CT) in combination with labelled cells is virtually non-existent due to the limited sensitivity of X-ray-absorption-based imaging, but would be highly desirable to realise cell tracking studies in entire organisms. In this study we applied in-line free propagation X-ray phase-contrast CT (XPCT) in an allergic asthma mouse model to assess structural changes as well as the biodistribution of barium-labelled macrophages in lung tissue. Alveolar macrophages that were barium-sulfate-loaded and fluorescent-labelled were instilled intratracheally into asthmatic and control mice. Mice were sacrificed after 24 h, lungs were kept in situ, inflated with air and scanned utilizing XPCT at the SYRMEP beamline (Elettra Synchrotron Light Source, Italy). Single-distance phase retrieval was used to generate data sets with ten times greater contrast-to-noise ratio than absorption-based CT (in our setup), thus allowing to depict and quantify structural hallmarks of asthmatic lungs such as reduced air volume, obstruction of airways and increased soft-tissue content. Furthermore, we found a higher concentration as well as a specific accumulation of the barium-labelled macrophages in asthmatic lung tissue. It is believe that XPCT will be beneficial in preclinical asthma research for both the assessment of therapeutic response as well as the analysis of the role of the recruitment of macrophages to inflammatory sites.

  20. Evaluation of potential gastrointestinal contrast agents for echoplanar MR imaging

    International Nuclear Information System (INIS)

    Reimer, P.; Schmitt, F.; Ladebeck, R.; Graessner, J.; Schaffer, B.

    1993-01-01

    The purpose of this study was to investigate approved aqueous gastrointestinal contrast agents for use in abdominal EPI. Conventional and echoplanar MR imaging experiments were performed with 1.0 Tesla whole body systems. Phantom measurements of Gastrografin, barium sulfate suspension, oral gadopentetate dimeglumine, water, and saline were performed. Signal intensity (SI) of aqueous oral barium sulfate and iodine based CT contrast agents was lower on conventional spin-echo (SE), Flash, and Turbo-Flush images than on EP images. The contrast agents exhibited higher SI on T2-weighted SE PE images and TI-time dependence on inversion recovery EP-images. The barium sulfate suspension was administered in volunteers to obtain information about bowel lumen enhancement and susceptibility artifacts. Oral administration of the aqueous barium sulfate suspension increased bowel lumen signal and reduced susceptibility artifacts. (orig.)

  1. Comparison of differently viscous iodinated and bariumcontaining contrast agents in the detection of pharyngeal perforation

    International Nuclear Information System (INIS)

    Keberle, M.; Wittenberg, G.; Trusen, A.; Hahn, D.; Baumgartner, W.

    2001-01-01

    Purpose: In contrast to esophageal perforations, the more radiopaque barium-suspensions are not as important as iodinated aqueous contrast agents for the detection of pharyngeal perforations. This study was performed to find out whether the highly different viscosities (of iodinated and barium-containing contrast agents with comparable radiopacities) are a reason for this. Methods: Viscosity, subjective difference in contrast, and CT-density of an iodinated aqueous (Telebrix) and a 50 wt/vol% barium-containing contrast agent (Micropaque) were determined. Moreover, to exclude postoperative perforation, 104 patients were prospectively examined by pharyngography using both contrast media. Pharyngographies of patients with perforation were later compared by two independent readers. All patients with perforation were followed up clinically to exclude complications due to barium administration. Results: In-vitro comparison showed comparable radiopacity but the 50 wt/vol% barium-suspension was much more viscous that the iodinated contrast agent. During pharyngography, totally, 14 perforations were clearly delineated with the iodinated aqueous contrast agent. However, two of them were not detected with the barium-suspension. All the other perforations presented equally. Conclusions: Given a sufficient radiopacity, a low viscosity appears to be essential for a contrast agent to detect especially pharyngeal perforations. Thus, we recommend the sole use of an iodinated contrast agent (at suspicion of aspiration as isoosmolar variant) for this purpose. (orig.) [de

  2. Epidermal growth factor enemas for induction of remission in left-sided ulcerative colitis Enemas de factor de crecimiento epidérmico para inducir la remisión de la colitis ulcerosa izquierda

    Directory of Open Access Journals (Sweden)

    Hugo Nodarse-Cuní

    2013-03-01

    Full Text Available Introduction: ulcerative colitis is a little known chronic inflammatory disease in colonic mucosa. The positive effect of epidermal growth factor was shown in a previous report, with enema use for treatment of mild to moderate left-sided manifestation of the disease. This evidence provided the basis for evaluating the efficacy and safety profile of a viscous solution of this product. Methods: thirty-one patients were randomized to three groups for daily medications during 14 days. Twelve received one 10 mg enema of epidermal growth factor dissolved in 100 mL of viscous solution whereas nine were treated with placebo enema; both groups also received 1.2 g of oral mesalamine per day. The other group included ten patients with 3 g / 100 mL of mesalamine enema. Primary end point was clinical responses after two weeks of treatment, defined as a decreased of, at least three points from baseline, the Disease Activity Index and endoscopic or histological evidences of improvement. Results: remission of disease was observed in all patients in the epidermal growth factor group, and six in both, mesalamine enema and placebo group. All the comparisons between groups showed statistically significant superiority for epidermal growth factor, the only product with significant reduction in disease activity index as well as the presence and intensity of digestive symptoms in patients after treatment. None adverse event was reported. Conclusions: the results agree with previous molecular and clinical evidences, indicating that the epidermal growth factor is effective to reduce disease activity and to induce remission. A new study involving more patients should be conducted to confirm the efficacy of the epidermal growth factor enemas.Introducción: la colitis ulcerosa es una enfermedad inflamatoria crónica de etiología poco conocida, que afecta la mucosa del colon. El efecto positivo del factor de crecimiento epidérmico fue reportado en estudio previo con uso de

  3. Effect of rectal enema on intrafraction prostate movement during image-guided radiotherapy.

    Science.gov (United States)

    Choi, Youngmin; Kwak, Dong-Won; Lee, Hyung-Sik; Hur, Won-Joo; Cho, Won-Yeol; Sung, Gyung Tak; Kim, Tae-Hyo; Kim, Soo-Dong; Yun, Seong-Guk

    2015-04-01

    Rectal volume and movement are major factors that influence prostate location. The aim of this study was to assess the effect of a rectal enema on intrafraction prostate motion. The data from 12 patients with localised prostate cancer were analysed. Each patient underwent image-guided radiotherapy (RT), receiving a total dose of 70 Gy in 28 fractions. Rectal enemas were administered to all of the patients before each RT fraction. The location of the prostate was determined by implanting three fiducial markers under the guidance of transrectal ultrasound. Each patient underwent preparation for IGRT twice before an RT fraction and in the middle of the fraction. The intrafraction displacement of the prostate was calculated by comparing fiducial marker locations before and in the middle of an RT fraction. The rectal enemas were well tolerated by patients. The mean intrafraction prostate movement in 336 RT fractions was 1.11 ± 0.77 mm (range 0.08-7.20 mm). Intrafraction motions of 1, 2 and 3 mm were observed in 56.0%, 89.0% and 97.6% of all RT fractions, respectively. The intrafraction movements on supero-inferior and anteroposterior axes were larger than on the right-to-left axes (P movement, calculated using the van Herk formula (2.5Σ + 0.7σ), was 1.50 mm. A daily rectal enema before each RT fraction was tolerable and yielded little intrafraction prostate displacement. We think the use of rectal enemas is a feasible method to reduce prostate movement during RT. © 2014 The Royal Australian and New Zealand College of Radiologists.

  4. Effect of rectal enema on intrafraction prostate movement during image-guided radiotherapy

    International Nuclear Information System (INIS)

    Choi, Youngmin; Kwak, Dong-Won; Lee, Hyung-Sik; Hur, Won-Jooh; Cho, Won-Yeol; Sung, Gyung Tak; Kim, Tae-Hyo; Kim, Soo-Dong; Yun, Seong-Guk

    2015-01-01

    Rectal volume and movement are major factors that influence prostate location. The aim of this study was to assess the effect of a rectal enema on intrafraction prostate motion. The data from 12 patients with localised prostate cancer were analysed. Each patient underwent image-guided radiotherapy (RT), receiving a total dose of 70 Gy in 28 fractions. Rectal enemas were administered to all of the patients before each RT fraction. The location of the prostate was determined by implanting three fiducial markers under the guidance of transrectal ultrasound. Each patient underwent preparation for IGRT twice before an RT fraction and in the middle of the fraction. The intrafraction displacement of the prostate was calculated by comparing fiducial marker locations before and in the middle of an RT fraction. The rectal enemas were well tolerated by patients. The mean intrafraction prostate movement in 336 RT fractions was 1.11 ± 0.77 mm (range 0.08–7.20 mm). Intrafraction motions of 1, 2 and 3 mm were observed in 56.0%, 89.0% and 97.6% of all RT fractions, respectively. The intrafraction movements on supero-inferior and anteroposterior axes were larger than on the right-to-left axes (P < 0.05). The CTV-to-PTV margin necessary to allow for movement, calculated using the van Herk formula (2.5Σ + 0.7σ), was 1.50 mm. A daily rectal enema before each RT fraction was tolerable and yielded little intrafraction prostate displacement. We think the use of rectal enemas is a feasible method to reduce prostate movement during RT.

  5. Accelerating the transit time of barium sulphate suspensions in small bowel examinations

    International Nuclear Information System (INIS)

    Summers, David S.; Roger, Mark D.; Allan, Paul L.; Murchison, John T.

    2007-01-01

    Purpose: To determine whether hyperosmolar and effervescent agents proven individually to accelerate transit time in the barium small bowel examination have an additive effect when combined, surpassing that of either agent alone. Materials and methods: One hundred and forty-nine patients were randomised to four groups. Three hundred milliliters of barium sulphate alone was given to the first group. Fifteen milliliters of iodinated hyperosmolar contrast agent (Gastrografin, meglumine/sodium diatrizoate, Schering) was given in addition to barium sulphate to the second group while six packets of effervescent granules (Carbex, Ferring) were added for the third group. The final group was given a combination of both additives and barium sulphate. The time taken following ingestion for the contrast column to reach the caecum, as assessed by frequent interval fluoroscopy, was recorded. A subgroup of 32 patients were selected randomly from the four groups, 8 from each and assessed for quality of examination. Statistical assessments were made using Kruskal-Wallis and Mann-Whitney tests. Results: One hundred and nineteen patients were analysed after exclusions. The addition of accelerant to barium sulphate, both individually and in combination significantly reduced the small bowel transit time (p < 0.001). No significant difference existed between the additives when used with barium alone. The combined group had significantly faster transit times compared to the hyperosmolar group (p = 0.02). Differences between combined and effervescent groups tended towards significance (p = 0.09). No significant difference existed between groups when examination quality was assessed. Conclusion: These results suggest that the addition of combined effervescent and hyperosmolar agents to the barium suspension may significantly shorten the small bowel transit time without adversely affecting examination quality. This has implications for patient acceptability of the examination as well as

  6. Synthesis of barium mercaptides and application of antimony/barium mercaptides

    Institute of Scientific and Technical Information of China (English)

    瞿龙; 张露露; 舒万艮

    2001-01-01

    Mercaptoacetic acid, isooctyl thioglycolate and barium hydroxide used as start materials, barium bis (2-ethylhexyl thioglycolate) (Ba(2EHTG)2), barium thioglycolate (Ba(TG)) and barium bisthioglycolate (Ba(TG)2) were synthesized. Their optimum synthetic techniques were discussed, and some physicochemical data were reported. Infrared spectroscopy and elemental analysis methods were used to identify the structures. They were put into PVC plastic products together with antimony tris (2-ethylhexyl thioglycolate) (Sb(2EHTG)3) under the suitable compounding, and their heat stability to PVC was studied. It is shown that these barium mercaptides have remarkable synergisms with antimony mercaptides and the long-term stabilizing effect of organoantimony stabilizer can be effectively improved, reducing the amount of antimony compounds so as to avoid the decrease of its stabilizing effect.

  7. Experimental antegrade enema: effects on water, electrolyte and acid-base balances with different solutions Enema anterógrado experimental: equilíbrio hídrico eletrolítico e ácido-base em coelhos submetidos a enema com diferentes soluções

    Directory of Open Access Journals (Sweden)

    Laura Helman

    2007-10-01

    Full Text Available PURPOSE: To study the effects on the water, electrolyte, and acid-base balances in rabbits submitted to antegrade enema with different solutions through appendicostomy. METHODS: Forty male New Zealand rabbits were submitted to appendicostomy, and distributed in 4 groups, according to the antegrade enema solution: PEG group, polyethylene glycol electrolyte solution (n=10; ISS group, isotonic saline solution (n=10; GS group, glycerin solution (n=10; SPS group, sodium phosphate solution (n=10. After being weighed, arterial blood gas analysis, red blood count, creatinine and electrolytes were measured at 4 times: preoperatively (T1; day 6 postop, before enema (T2; 4h after enema (T3; and 24h after T3 (T4. RESULTS: In PEG group occurred Na retention after 4h, causing alkalemia, sustained for 24h with HCO3 retention. In ISS group occurred isotonic water retention and hyperchloremic acidosis after 4h, which was partially compensated in 24h. GS group showed metabolic acidosis after 4h, compensated in 24h. In SPS group occurred hypernatremic dehydration, metabolic acidosis in 4h, and hypokalemia, hypocalcemia, hypomagnesemia, and metabolic alkalosis with partially compensated dehydration in 24h. CONCLUSIONS: All solutions used in this study caused minor alterations on water, electrolyte or acid-base balances. The most intense ones were caused by hypertonic sodium phosphate solution (SPS and isotonic saline solution (ISS and the least by polyethyleneglycol electrolyte solution (PEG and glycerin solution 12% (GS.OBJETIVO: Estudar os efeitos no equilíbrio hídrico, eletrolítico e ácido-base, do enema anterógrado com diferentes soluções em coelhos através de apendicostomia. MÉTODOS: 40 coelhos Nova Zelândia, machos, submetidos a apendicostomia, distribuídos em quatro grupos segundo a solução de enema: grupo PEG (n = 10 solução de polietilenoglicol com eletrólitos; grupo SF (n = 10 solução fisiológica; grupo SG (n = 10 solução glicerinada

  8. Allergic colitis: a mimic of Hirschsprung disease

    International Nuclear Information System (INIS)

    Bloom, D.A.; Buonomo, C.; Fishman, S.J.; Furuta, G.; Nurko, S.

    1999-01-01

    Background. Allergy to cow milk protein is a common cause of gastrointestinal symptoms in infancy. Milk allergy is usually a clinical diagnosis, and thus there have been few reports of the radiographic findings. Objective. To describe the barium enema findings of allergic colitis and differentiate them from Hirschsprung disease. Materials and methods. Four infants (age range 7 days-5 weeks) with constipation underwent barium enema to exclude Hirschsprung disease. Radiographic findings were correlated with the pathologic specimens from suction rectal biopsy. Results. All enemas revealed irregular narrowing of the rectum and a transition zone. Rectal biopsies in each case demonstrated ganglion cells and evidence of an allergic colitis, with inflammatory infiltrates in the lamina propria. A diagnosis of milk allergy colitis was made and symptoms resolved after removal of milk from the diet. Conclusions. Milk allergy is common in infancy. The rectum is a primary target organ, with allergic colitis often diagnosed on clinical grounds alone. However, a child with allergic colitis may be referred to radiology for barium enema, especially if constipation is present. The radiologist should be aware of the unique imaging findings of allergic colitis, so as to avoid confusion with Hirschsprung disease and perhaps an unnecessary rectal biopsy. (orig.)

  9. Sulphate removal from sodium sulphate-rich brine and recovery of barium as a barium salt mixture.

    Science.gov (United States)

    Vadapalli, Viswanath R K; Zvimba, John N; Mulopo, Jean; Motaung, Solly

    2013-01-01

    Sulphate removal from sodium sulphate-rich brine using barium hydroxide and recovery of the barium salts has been investigated. The sodium sulphate-rich brine treated with different dosages of barium hydroxide to precipitate barium sulphate showed sulphate removal from 13.5 g/L to less than 400 mg/L over 60 min using a barium to sulphate molar ratio of 1.1. The thermal conversion of precipitated barium sulphate to barium sulphide achieved a conversion yield of 85% using coal as both a reducing agent and an energy source. The recovery of a pure mixture of barium salts from barium sulphide, which involved dissolution of barium sulphide and reaction with ammonium hydroxide resulted in recovery of a mixture of barium carbonate (62%) and barium hydroxide (38%), which is a critical input raw material for barium salts based acid mine drainage (AMD) desalination technologies. Under alkaline conditions of this barium salt mixture recovery process, ammonia gas is given off, while hydrogen sulfide is retained in solution as bisulfide species, and this provides basis for ammonium hydroxide separation and recovery for reuse, with hydrogen sulfide also recoverable for further industrial applications such as sulfur production by subsequent stripping.

  10. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough.

    Science.gov (United States)

    Nin, Carlos Shuler; Marchiori, Edson; Irion, Klaus Loureiro; Paludo, Artur de Oliveira; Alves, Giordano Rafael Tronco; Hochhegger, Daniela Reis; Hochhegger, Bruno

    2013-01-01

    To assess the routine use of barium swallow study in patients with chronic cough. Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks) were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological changes. Fisher's exact test and the chi-square test for categorical data were used in the comparisons. The images taken immediately after barium swallow revealed significant pathological conditions that were potentially related to chronic cough in 12 (12.6%) of the 95 patients. These conditions, which included diaphragmatic hiatal hernia, esophageal neoplasm, achalasia, esophageal diverticulum, and abnormal esophageal dilatation, were not detected on the images taken without contrast. After appropriate treatment, the symptoms disappeared in 11 (91.6%) of the patients, whereas the treatment was ineffective in 1 (8.4%). We observed no complications related to barium swallow, such as contrast aspiration. Barium swallow improved the detection of significant radiographic findings related to chronic cough in 11.5% of patients. These initial findings suggest that the routine use of barium swallow can significantly increase the sensitivity of chest X-rays in the detection of chronic cough-related etiologies.

  11. Rectosigmoid endometriosis: Comparison between CT water enema and video laparoscopy

    International Nuclear Information System (INIS)

    Stabile Ianora, A.A.; Moschetta, M.; Lorusso, F.; Lattarulo, S.; Telegrafo, M.; Rella, L.; Scardapane, A.

    2013-01-01

    Aim: To evaluate the accuracy of water enema computed tomography (CT) for predicting the location of endometriosis in patients with contraindications to magnetic resonance imaging (MRI), focusing on rectosigmoid lesions and having laparoscopic and histological data as the reference standard. Materials and methods: Thirty-three women (mean age 33.4 ± 3.1 years) suspected of having deep pelvic endometriosis underwent 64-row CT and video laparoscopy within 4 weeks. Two radiologists blinded to the clinical data evaluated the CT images obtained after colonic retrograde distension using water as the contrast medium, and a comparison with laparoscopic and histological findings was performed. CT sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. The radiation dose to patients was estimated. Cohen's weighted kappa (κ) test was used to evaluate the interobserver agreement. Results: In 23 out of 33 patients (69%) intestinal implants were found at surgery and pathological examinations. CT confirmed the diagnosis of rectosigmoid endometriosis in 20 out of 23 implants. Three nodules located on the proximal sigmoid colon (two serosal lesions and one infiltrating the muscularis layer) with a diameter of less than 1 cm were not diagnosed. CT sensitivity, specificity, PPV, NPV, and accuracy values were 87, 100, 100, 77, and 91%, respectively. The mean effective dose estimate was 6.30 ± 1.7 mSv. Almost perfect agreement between the two readers was found (k = 0.84). Conclusion: Water enema CT can play a role in the diagnosis of bowel endometriosis and represents another accurate potential tool for video laparoscopic approaches, especially in patients for whom MRI is contraindicated

  12. Comparison of Sucralfate and Hydrocortisone Enemas in Treatment of Active Ulcerative Proctitis; A Double-Blind Randomized ClinicalL Trial

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Javadi

    2003-08-01

    Full Text Available Sucralfate enema has been proposed and investigated in treatment of ulcerative proctitis, but its efficacy is still a matter of debate. Hydrocortisone enema is still an established drug in treatment of ulcerative proctitis. This study was designed to compare the effect of sucralfate enema with hydrocortisone enema. Patients with active sigmoidoscopic and histologic features of ulcerative proctitis were included. All patients had clinical manifestations of proctitis for at least four weeks prior to the study and had negative parasitic stool culture. The total of 25 patients entered the study. They were randomly divided in two groups; group I (n =14 and group II (n = 11 who received sucralfate and hydrocortisone enemas respectively for 4 weeks. Both groups had a significant improvement in clinical features, histologic activity and sigmoidoscopic evaluation in comparison with the baseline. Furthermore there was no significant differences between the two groups concerning mean changes of clinical, sigmoidoscopic, and histologic grading, after treatment. Considering the low cost and minimal adverse effects of sucralfate, and almost equal efficacy in comparison with hydrocortisone enema, its usage can be recommended.

  13. Isotopic exchange reaction between barium ion and tri barium phosphate

    International Nuclear Information System (INIS)

    Bilgin, G.B.; Cetin, I.

    1982-01-01

    Heterogeneous exchange reaction of tri barium phosphate in barium chloride solution has been studied using 133 Ba as a tracer. The results show that the exchange fraction increases as barium chloride concentration increases for different mole ratio of the exchange ion on the solid surface and in the solution. The phenomenon was studied with respect to the previous treatment of the precipitate leading to different crystal sizes and the effect of reaction time. (author)

  14. On barium oxide solubility in barium-containing chloride melts

    International Nuclear Information System (INIS)

    Nikolaeva, Elena V.; Zakiryanova, Irina D.; Bovet, Andrey L.; Korzun, Iraida V.

    2016-01-01

    Oxide solubility in chloride melts depends on temperature and composition of molten solvent. The solubility of barium oxide in the solvents with barium chloride content is essentially higher than that in molten alkali chlorides. Spectral data demonstrate the existence of oxychloride ionic groupings in such melts. This work presents the results of the BaO solubility in two molten BaCl 2 -NaCl systems with different barium chloride content. The received data together with earlier published results revealed the main regularities of BaO solubility in molten BaO-BaCl 2 -MCl systems.

  15. Intestinal preparation for colon enema with fosfo-soda fleet versus the conventional method

    International Nuclear Information System (INIS)

    Vecchioli Caldazza, A.; Celi, G.; De Franco, A.; Parrella, A.; Minordi, L.M.; Marano, P.

    1999-01-01

    The authors evaluate the possible optimization of a well-tolerated and versatile method of intestinal preparation able to adequately free the lumen and consequently improve diagnostic results with a lower risk of prolonged hospital stay for incorrectly prepared patients. They examined 40 patients, namely 20 men and 20 women referred to the Institute of radiology of the 'Sacro Cuore' Catholic University of Rome (Italy), Gastrointestinal tract unit, to undergo double contrast colonic enema. The statistical analysis of all data was performed with Wilcoxon test. Intestinal preparation with fosfo-soda fleet appeared to be definitely better than the conventional method relative to tolerance, while providing similarly satisfactory data relative to the other parameters [it

  16. Patient dose assessment from fluoroscopic procedures at Korle-Bu Teaching Hospital

    International Nuclear Information System (INIS)

    Gyekye, P. K.

    2008-06-01

    Organ and effective dose to ninety (90) patients undergoing myelogram, urethrogram, barium swallow, barium meal and barium enema examinations at the KorIe-Bu Teaching Hospital was estimated using the Monte Carlo Code (PCXMC). Free in air measurements were made with a calibrated ionisation chamber to estimate the entrance surface air kerma for each examination. Evaluation of fluoroscopy beam on time and number of radiographs taken per patient was done for all the examinations considered and studies were done on how they affect patient dose. Dose area product (DAP) was calculated from the entrance surface air kerma and the area of the beam on the surface of the patient and compared with internationally accepted reference levels. Excess relative risk of site specific solid cancer and all solid cancers excluding thyroid and Non-melanoma skin cancers incidences were estimated for the various examinations using Biological Effects of Ionising Radiation VII Committee risk model from the knowledge of the mean effective doses for each examination. The mean effective dose was found to be 0.29 :±: 0.07 mSv for urethrogram, 0.84:±: 0.13 mSv for barium swallow, 3.15 :±: 0.44 mSv for barium meal, 6.24 :±: 0.7 mSv for barium enema and 0.38 :I: 0.05 mSv for myelogram examinations. The estimated mean dose area product (DAP) was found to be 3.55 :±: 0.95 Gycm2 for urethrogram, 16.44:1: 2.60 Gycm2 for barium swallow, 50.81 :±: 7.04 Gycm2 for barium meal, 99.69 :±: 10.85 Gycm2 for barium enema and 9.32 :±: 0.99 Gycm2 for myelogram examinations. The estimated excess relative risk for the occurrence of all solid cancer was found to be 9.5700E-S and 1.6530E-4 for males and females respectively undergoing urethrogram examination, 2.7720E-4 and 4.7880E-4 for males and females respectively undergoing barium swallow examination, 1.0395E-3 and 1.7955E-3 for males and females respectively undergoing barium meal examination, 2.0592E-3 and 3.5568E-3 for males and females respectively

  17. Double-contrast barium enteroclysis as a patency tool for nonsteroidal anti-inflammatory drug-induced enteropathy.

    Science.gov (United States)

    Matsumoto, Takayuki; Esaki, Motohiro; Kurahara, Koichi; Hirai, Fumihito; Fuchigami, Tadahiko; Matsui, Toshiyuki; Iida, Mitsuo

    2011-11-01

    Evaluating small bowel patency is recommended for capsule endoscopy in patients suspected of nonsteroidal anti-inflammatory drug-induced (NSAID) enteropathy. The aim of this investigation was to examine whether radiography is a candidate of patency tool in NSAID enteropathy. We reviewed double-contrast barium enteroclysis in 21 patients with NSAID enteropathy diagnosed either by capsule endoscopy or balloon-assisted endoscopy. The endoscopic findings were classified into circular ulcers, linear ulcers and small mucosal defects. The radiographic signs of the corresponding endoscopic findings were retrieved and the depiction rate was calculated. Of the 21 patients, endoscopy detected circular ulcers, linear ulcers, and small ulcers in 12, 3 and 12 patients, respectively. Small bowel radiography depicted circular narrowing as pseudo-folds in 10 patients (83%) and linear ulcers as eccentric rigidity in 2 patients (67%). However, radiography was able to depict small mucosal defects in only 3 patients (17%). Two of 5 patients with pseudo-folds experienced retention of the capsule. "Pseudo-folds" is a sign corresponding to circular ulcer in NSAID enteropathy, which may be predictive of capsule retention.

  18. A randomized trial of enema versus polyethylene glycol 3350 for fecal disimpaction in children presenting to an emergency department.

    Science.gov (United States)

    Miller, Melissa K; Dowd, Mary Denise; Friesen, Craig A; Walsh-Kelly, Christine M

    2012-02-01

    This study aimed to compare efficacy of enema versus polyethylene glycol (PEG) 3350 for pediatric fecal impaction treatment. We conducted a prospective, randomized comparison of treatments of fecal impaction in children in a pediatric emergency department (ED). Treatment arms were a single milk and molasses enema in the ED or PEG 3350 for 3 days outpatient. Telephone follow-up was done on days 1, 3, and 5. The primary outcome was main symptom improvement. Additional outcomes were stool frequency, consistency, and ease of stool passage. Treatment failures (home enema, ED return, or hospital admission) were tracked. Seventy-nine subjects participated (39 PEG; 40 enema). At day 1, PEG subjects were less likely to have improved main symptom (odds ratio [OR], 0.3; 95% confidence interval [CI], 0.1-0.8) but no difference in other outcomes. Half (54%) in enema arm were reported as upset by ED therapy, whereas no children in PEG arm were upset (P PEG arm (83%; P = 0.08). This pilot study suggests that disimpaction by enema may be superior to PEG for immediate relief of symptoms. Larger trials are needed to assess any advantage.

  19. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough

    Directory of Open Access Journals (Sweden)

    Carlos Shuler Nin

    2013-12-01

    Full Text Available OBJECTIVE: To assess the routine use of barium swallow study in patients with chronic cough.METHODS: Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological changes. Fisher's exact test and the chi-square test for categorical data were used in the comparisons.RESULTS: The images taken immediately after barium swallow revealed significant pathological conditions that were potentially related to chronic cough in 12 (12.6% of the 95 patients. These conditions, which included diaphragmatic hiatal hernia, esophageal neoplasm, achalasia, esophageal diverticulum, and abnormal esophageal dilatation, were not detected on the images taken without contrast. After appropriate treatment, the symptoms disappeared in 11 (91.6% of the patients, whereas the treatment was ineffective in 1 (8.4%. We observed no complications related to barium swallow, such as contrast aspiration.CONCLUSIONS: Barium swallow improved the detection of significant radiographic findings related to chronic cough in 11.5% of patients. These initial findings suggest that the routine use of barium swallow can significantly increase the sensitivity of chest X-rays in the detection of chronic cough-related etiologies.

  20. Rectosigmoid endometriosis: comparison between CT water enema and video laparoscopy.

    Science.gov (United States)

    Stabile Ianora, A A; Moschetta, M; Lorusso, F; Lattarulo, S; Telegrafo, M; Rella, L; Scardapane, A

    2013-09-01

    To evaluate the accuracy of water enema computed tomography (CT) for predicting the location of endometriosis in patients with contraindications to magnetic resonance imaging (MRI), focusing on rectosigmoid lesions and having laparoscopic and histological data as the reference standard. Thirty-three women (mean age 33.4 ± 3.1 years) suspected of having deep pelvic endometriosis underwent 64-row CT and video laparoscopy within 4 weeks. Two radiologists blinded to the clinical data evaluated the CT images obtained after colonic retrograde distension using water as the contrast medium, and a comparison with laparoscopic and histological findings was performed. CT sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. The radiation dose to patients was estimated. Cohen's weighted kappa (κ) test was used to evaluate the interobserver agreement. In 23 out of 33 patients (69%) intestinal implants were found at surgery and pathological examinations. CT confirmed the diagnosis of rectosigmoid endometriosis in 20 out of 23 implants. Three nodules located on the proximal sigmoid colon (two serosal lesions and one infiltrating the muscularis layer) with a diameter of less than 1 cm were not diagnosed. CT sensitivity, specificity, PPV, NPV, and accuracy values were 87, 100, 100, 77, and 91%, respectively. The mean effective dose estimate was 6.30 ± 1.7 mSv. Almost perfect agreement between the two readers was found (k = 0.84). Water enema CT can play a role in the diagnosis of bowel endometriosis and represents another accurate potential tool for video laparoscopic approaches, especially in patients for whom MRI is contraindicated. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Exposure to radiologic contrast media and an increased risk of treated end-stage renal disease.

    Science.gov (United States)

    Muntner, Paul; Coresh, Josef; Klag, Michael J; Whelton, Paul K; Perneger, Thomas V

    2003-12-01

    Radiologic contrast media can cause acute renal failure, but whether their repeated use is associated with end-stage renal disease (ESRD) is unknown. We compared 716 incident case subjects of treated ESRD with 361 control subjects, frequency matched on age, drawn from the general population (age, 20-65 years). Participants were interviewed by telephone regarding their previous exposure (before initiation of dialysis for case subjects and the study interview for control subject) to various imaging procedures. As expected, the case subjects reported having more imaging procedures of the kidneys than did control subjects. Excluding persons who had been subjected to examinations of their kidney from the analysis and adjusting for ultrasound examinations and several possible confounders, persons who had a history of one [odds ratio (OR), 2.0; 95% confidence interval (CI), 1.0, 4.0], 2 or 3 (OR, 2.6; 95% CI, 1.2,5.9), or 4 or more (OR, 3.6; 95% CI, 1.0, 12.5) radiocontrast examinations were at higher risk of treated ESRD than persons who reported not having had such procedures. Ultrasound examinations and a history of barium enema were not associated with an increased risk of treated ESRD. In the current study, a graded association was present between increasing exposure to radiologic contrast media and higher risk of treated ESRD. Whether exposure to contrast media accelerates progression to ESRD or is merely a noncausal accompaniment to multiple disease processes occurring concurrently cannot be determined from our observational data. However, if these results are confirmed in future prospective studies, they will have important clinical implications.

  2. Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

    Science.gov (United States)

    Kingston, Mitchell J; Perriman, Diana M; Neeman, Teresa; Smith, Paul N; Webb, Alexandra L

    2016-07-01

    Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra- and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Lithium in the barium stars

    International Nuclear Information System (INIS)

    Pinsonneault, M.H.; Sneden, C.

    1984-01-01

    New high-resolution spectra of the lithium resonance doublet have provided lithium abundances or upper limits for 26 classical and mild barium stars. The lithium lines always are present in the classical barium stars. Lithium abundances in these stars obey a trend with stellar masses consistent with that previously derived for ordinary K giants. This supports the notion that classical barium stars are post-core-He-flash or core-He-burning stars. Lithium contents in the mild barium stars, however, often are much smaller than those of the classical barium stars sometimes only upper limits may be determined. The cause for this difference is not easily understood, but may be related to more extensive mass loss by the mild barium stars. 45 references

  4. Qualitative analysis of barium particles coated in small intestinal mucosa of rabbit by using scanning electron microscopy

    International Nuclear Information System (INIS)

    Lee, Yong Suk; Ha, Hyun Kwon; Lee, Yang Seob; Kim, Jae Kyun; Yoon, Seong Eon; Kim, Jung Hoon; Chung, Dong Jin; Auh, Yong Ho

    1998-01-01

    To qualitatively analysed barium coating status in the intestinal mucosa, we used scanning electron microscopy to observe barium particles coated in the small intestinal mucosa of rabbit, and we attempted to assess the relationship between electron microscopic findings and radiographic densities. Six different combination of barium and methylcellulose suspensions were infused into the resected small intestines of 15 rabbits. Barium powders were mixed with water to make 40% and 70% w/v barium solutions, and also mixed with 0.5% methylcellulose solutions were used as a double contrast agent. After the infusion of barium suspensions, a mammography unit was used to obtain radiographs of the small intestine, and their optical densities were measured by a densitometer. Thereafter, photographs of barium-coated small intestinal mucosa were obtained using a scanning electron microscope (x 8,000), and the number of barium particles in the unit area were measured. To compare the relationship between the electron microscopic findings and optical densities, statistical analysis using Spearman correlation was performed. This study shows that by using scanning electron microscopy, barium particles coated on the small intestinal mucosa can be qualitatively analysed. It also shows that the number of small barium particles measured by scanning electron microscopy is related to optical densities. (author). 14 refs., 2 figs

  5. Evaluation of contrast media for bronchography

    International Nuclear Information System (INIS)

    Thompson, I.M.; Whittlesey, G.C.; Slovis, T.L.; Chang, C.H.; Cullen, M.L.; Philippart, A.I.; Stockmann, P.S.; Adkins, E.S.; Klein, M.D.

    1997-01-01

    Background. Bronchography is occasionally needed for the evaluation and management of some congenital pulmonary anomalies as well as some acquired diseases, usually of the tracheo- bronchial tree. There is currently no effective, approved contrast agent for this imaging tech- nique. Objective. We evaluated five agents (barium sulfate, iohexol, propyliodone oily, propyliodone aqueous, and perflubron) in terms of image quality, histologic changes, and effects on hemodynamics, blood gases, and standard laboratory tests in New Zealand White rabbits. Materials and methods. Animals were anesthetized and intubated. Each contrast agent (0.25 ml/kg) was administered intratracheally. Three animals in each group had intravenous lines placed for blood sampling and blood pressure monitoring and were sacrificed at 1 h. An additional three animals for each agent were sacrificed at 24 h and 1 week after imaging. Blood samples were taken immediately before contrast instillation and at 1 h postbronchography. Fluoroscopic images were recorded on standard VHS video tape and evaluated in blind fashion. Segments of lung tissue and bronchi were obtained for histologic examination. Results. Necrosis and/or inflammatory infiltrates were noted in 78 % of the bronchograms performed with propyliodone aqueous, 67 % with propyliodone oily, 55 % with perflubron, and 33 % with iohexol 120, 240 and 350. No histologic damage was observed with barium. The propyliodones gave the best-quality imaging results and the most histologic changes. Iohexol, in any concentration, gave the least acceptable images and a moderate number of histologic changes. Barium sulfate demonstrated acceptable images with virtually no histologic changes. Conclusion. From the histologic and imaging results, barium is the best available contrast material for bronchography. (orig.). With 6 figs., 4 tabs

  6. Sucralfate paste enema: a new method of topical treatment for haemorrhagic radiation proctitis.

    Science.gov (United States)

    McElvanna, K; Wilson, A; Irwin, T

    2014-04-01

    Rectal sucralfate has been reported to deliver clinical improvement in haemorrhagic radiation proctitis, but patients with active proctitis find the enema suspension difficult to retain thus reducing compliance and effectiveness. We describe a novel method of rectal administration via a low-volume sucralfate paste and report its results in a series of 23 patients. Patients with rectal bleeding occurring more than 6 months after radiotherapy were shown how to prepare and self-administer sucralfate paste enemas (SPEs) twice daily for 6 weeks. The SPE was prepared using two sucralfate 1-g tablets mixed with 4.5 ml of water in an enema applicator producing a low-volume paste. The clinical response was evaluated by comparison of pre- and posttreatment clinical proctitis scores (Radiation Therapy Oncology Group/European Organisation for Research and Treatment of Cancer). Eighteen male (postprostatic radiotherapy) and five female (postcervical radiotherapy) patients with a median age of 67 (32-75) years were included. The median interval between pelvic irradiation and SPE treatment was 24 (7-69) months. Twenty-two patients had full clinical scoring, of whom 16 (73%) demonstrated clinical improvement. Six (27%) had neither clinical improvement nor deterioration. Seven (32%) had resolution of all symptoms. Most patients demonstrated clinical improvement. This initial experience of the sucralfate paste enema may provide the basis for a prospective study of its effectiveness in the treatment of haemorrhagic radiation proctitis. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  7. Barium light source method and apparatus

    Science.gov (United States)

    Curry, John J. (Inventor); MacDonagh-Dumler, Jeffrey (Inventor); Anderson, Heidi M. (Inventor); Lawler, James E. (Inventor)

    2002-01-01

    Visible light emission is obtained from a plasma containing elemental barium including neutral barium atoms and barium ion species. Neutral barium provides a strong green light emission in the center of the visible spectrum with a highly efficient conversion of electrical energy into visible light. By the selective excitation of barium ionic species, emission of visible light at longer and shorter wavelengths can be obtained simultaneously with the green emission from neutral barium, effectively providing light that is visually perceived as white. A discharge vessel contains the elemental barium and a buffer gas fill therein, and a discharge inducer is utilized to induce a desired discharge temperature and barium vapor pressure therein to produce from the barium vapor a visible light emission. The discharge can be induced utilizing a glow discharge between electrodes in the discharge vessel as well as by inductively or capacitively coupling RF energy into the plasma within the discharge vessel.

  8. A prospective randomized single blind trial of Fleet phosphate enema versus glycerin suppositories as preparation for flexible sigmoidoscopy.

    Science.gov (United States)

    Underwood, D; Makar, R R; Gidwani, A L; Najfi, S M; Neilly, P; Gilliland, R

    2010-03-01

    This study compared the efficacy and patient acceptability of two methods of bowel preparation for flexible sigmoidoscopy. Patients attending for outpatient flexible sigmoidoscopy were prospectively randomized to receive one Fleet ready-to-use enema or 2 x 4 g glycerin suppositories, 2 h preprocedure. Patient and endoscopist questionnaires were used to compare the outcomes. From November 2000 to August 2001, 203 (male = 95; female = 108) patients were randomized. Patient data available for 163 patients (enema = 93; suppository = 70) revealed: ease of use (enema = 52; suppository = 25; P suppositories.

  9. High-Dose Barium Impaction Therapy Is Useful for the Initial Hemostasis and for Preventing the Recurrence of Colonic Diverticular Bleeding Unresponsive to Endoscopic Clipping

    Directory of Open Access Journals (Sweden)

    Ryota Niikura

    2013-01-01

    Full Text Available Most cases of colonic diverticular bleeding stop spontaneously, but some patients experience massive bleeding that requires emergency treatment. Endoscopy can be useful when the bleeding source is identified. However, bleeding sometimes recurs within a short period despite the successful endoscopic treatment. Under such conditions, more invasive therapy such as interventional angiography or surgery is required and can prolong hospitalization and involve frequent blood transfusions. We report the case of a 68-year-old woman who presented with massive hematochezia. The patient was in hemorrhagic shock and required 16 units of blood transfusion to recover to general condition. We performed multidetector row computed tomography, but it showed no sites of bleeding. We conducted colonoscopy and identified the source of bleeding as colonic diverticula. We treated the bleeding with endoscopic hemoclips and achieved hemostasis, but bleeding recurred the next day. Four units of blood transfusion were required. We tried high-dose barium impaction therapy to avoid further blood transfusion and surgery. No complications or recurrent bleeding was observed for an 18-month period. Therapeutic barium enema is an option for colonic diverticular bleeding unresponsive to endoscopic clipping and may be effective for preventing recurrent bleeding.

  10. Barium toxicosis in a dog.

    Science.gov (United States)

    Adam, Fiona H; Noble, Peter J M; Swift, Simon T; Higgins, Brent M; Sieniawska, Christine E

    2010-09-01

    A 2-year-old 14.9-kg (32.8-lb) neutered female Shetland Sheepdog was admitted to the University of Liverpool Small Animal Teaching Hospital for evaluation of acute collapse. At admission, the dog was tachypneic and had reduced limb reflexes and muscle tone in all limbs consistent with diffuse lower motor neuron dysfunction. The dog was severely hypokalemic (1.7 mEq/L; reference range, 3.5 to 5.8 mEq/L). Clinical status of the dog deteriorated; there was muscle twitching, flaccid paralysis, and respiratory failure, which was considered a result of respiratory muscle weakness. Ventricular arrhythmias and severe acidemia (pH, 7.18; reference range, 7.35 to 7.45) developed. Intoxication was suspected, and plasma and urine samples submitted for barium analysis had barium concentrations comparable with those reported in humans with barium toxicosis. Analysis of barium concentrations in 5 control dogs supported the diagnosis of barium toxicosis in the dog. Fluids and potassium supplementation were administered IV. The dog recovered rapidly. Electrolyte concentrations measured after recovery were consistently unremarkable. Quantification of plasma barium concentration 56 days after the presumed episode of intoxication revealed a large decrease; however, the plasma barium concentration remained elevated, compared with that in control dogs. To our knowledge, this case represented the first description of barium toxicosis in the veterinary literature. Barium toxicosis can cause life-threatening hypokalemia; however, prompt supportive treatment can yield excellent outcomes. Barium toxicosis is a rare but important differential diagnosis in animals with hypokalemia and appropriate clinical signs.

  11. Failure of 5-aminosalicylic acid enemas to improve chronic radiation proctitis

    International Nuclear Information System (INIS)

    Baum, C.A.; Biddle, W.L.; Miner, P.B. Jr.

    1989-01-01

    Radiation proctitis is a well-known complication of abdominal and pelvic radiation. Conventional medical and surgical treatment often is disappointing. 5-Aminosalicylic acid (5-ASA) is the active component in sulfasalazine and is effective in the treatment of distal ulcerative colitis. Four patients with radiation proctitis were treated with 4 g 5-ASA by enema nightly for two to six months. Patients were seen monthly, interviewed, and a sigmoidoscopic exam performed. No change was seen in the degree of mucosal inflammation on follow-up sigmoidoscopic exams. Three patients noted no change in their symptoms of bleeding, pain, or tenesmus. One patient noted initial improvement, but this was not sustained. 5-ASA enemas do not appear to be effective in the treatment of radiation proctitis

  12. Improved X-ray diagnosis of stomach by progress in the development of contrast media and examination techniques

    International Nuclear Information System (INIS)

    Lotz, W.

    1982-01-01

    Three factors have been responsible for the advances during the past few years in X-ray examination of the stomach: Improvement of the contrast media used; introduction of the rare-earth foils; and examination techniques imaging all sections of the stomach and of the duodenal bulb under hypotension in double-contrast technique, in complete filling, and imaging the accessible sections by means of proper compression. An interesting technique employs a combination of two different barium sulphate suspension used at the same time, e.g. Bubbly Barium or some other barium sulphate preparation with a small amount of High-Density Barium yielding excellent image of the gastric mucosa (technique with two contrast media). (orig.) [de

  13. Modeling and minimization of barium sulfate scale

    Science.gov (United States)

    Alan W. Rudie; Peter W. Hart

    2006-01-01

    The majority of the barium present in the pulping process exits the digester as barium carbonate. Barium carbonate dissolves in the bleach plant when the pH drops below 7 and, if barium and sulfate concentrations are too high, begins to precipitate as barium sulfate. Barium is difficult to control because a mill cannot avoid this carbonate-to-sulfate transition using...

  14. Observation of a barium xenon exciplex within a large argon cluster.

    Science.gov (United States)

    Briant, M; Gaveau, M-A; Mestdagh, J-M

    2010-07-21

    Spectroscopic measurements provide fluorescence and excitation spectra of a single barium atom codeposited with xenon atoms on argon clusters of average size approximately 2000. The spectra are studied as a function of the number of xenon atoms per cluster. The excitation spectrum with approximately 10 xenon atoms per cluster is qualitatively similar to that observed when no xenon atom is present on the cluster. It consists of two bands located on each side of the 6s6p (1)P-6s(2) (1)S resonance line of the free barium. In contrast, the fluorescence spectrum differs qualitatively since a barium-xenon exciplex is observed, which has no counterpart in xenon free clusters. In particular an emission is observed, which is redshifted by 729 cm(-1) with respect to the Ba(6s6p (1)P-6s(2) (1)S) resonance line.

  15. A Brief Review of Therapeutic and Diagnostic Applications of Enema in Iranian Traditional Medicine and Other Complementary Medicines

    Directory of Open Access Journals (Sweden)

    Hamideh khorrampazouh

    2018-02-01

    Full Text Available Introduction: Enema or ‘hoqne’ is a therapeutic approach used for a wide range of diseases in the Iranian traditional medicine. The use of this method dates back to thousands of years to Hippocrates and Galen. The aim of this study was to review the history of enema and its methods and indices in the Iranian medicine and other complementary medicine.Methods: This review study was conducted on the Iranian medicine textbooks and articles published in the international databases, including Google Scholar, PubMed, Embase, and Scopus, as well as the Iranian databases, such as SID and Magiran. The searching process was performed using the following keywords: ‘Hoqne’, ‘Enema’, ‘Vasta’, ‘Basta’, and ‘Complementary and Alternative Medicine (CAM’. There was no limitation regarding the publication data of the included studies.Result: In the Iranian medicine, the term “hoqne” is equivalent to enema. Enema is used in various diseases of the brain, respiratory system, digestive system, urogenital system, and musculoskeletal system, as well as systemic diseases. Enema is one of the five main therapies in the Indian medicine or Ayurveda. In other types of complementary medicine, including Chinese medicine, this procedure has therapeutic applications. Although enema has been recognized as a diagnostic method in modern medicine, it has been considered as a therapeutic approach in the recent years.Conclusion: According to the findings of the reviewed studies, enema is a major therapeutic focus in complementary medicine, part of which has been confirmed in the recent studies. Given the low side effects and high success rate of this treatment, it can be used as a supplemental therapy for the management of poisoning, febrile seizures, prolonged functional constipation, and chronic kidney disease, as well as the prevention of swelling. However, this theory requires further investigation and targeted clinical trials. This method has been

  16. Evaluation of sucralfate enema in experimental diversion colitis

    Directory of Open Access Journals (Sweden)

    José Aires Pereira

    2013-10-01

    Full Text Available Diversion colitis (DC is an inflammatory disease that develops in segments with fecal di- version. Sucralfate (SCF complex, which consists of sucrose octasulfate and polyaluminum hydroxide, has been demonstrated to be effective in the treatment of different forms of colitis. However, until now, the effects of SCF have not been evaluated in DC. Objective: to evaluate whether the use of enemas containing SFC improves histological find- ings in experimental DC. Methods: Thirty-six rats underwent right colon bypass procedure through the creation of a proximal colostomy and a distal mucous fistula. The animals were divided into two groups according to the euthanization procedure to be performed two to four weeks after sur- gery. Each experimental group was divided into three subgroups of six animals, which were submitted to daily application of enemas containing saline solution 0.9% or SCF at con- centrations of 1.0 g/kg/day or 2.0 g/kg/day, respectively. The diagnosis of DC in segments with fecal diversion was established by histopathological study considering the following variables: epithelial loss, formation of crypt abscesses, the population of goblet cells, in- flammatory infiltrate and presence of fibrosis. For statistical analysis, the nonparametric Mann-Whitney and Kruskal-Wallis tests were used, with a significance level of 5% (p <0.05. Results: It was observed that the daily application of SCF enemas decreased epithelial loss, formation of colon crypt abscesses, inflammatory infiltrate and tissue fibrosis (p <0.05, un- related to time of intervention. The intervention with SCF preserves the goblet cell popula- tion. The effects of the substance on the preservation of colonic epithelium; the decrease in the inflammatory process and subsequent abscess formation in the colon crypts are associated with the concentration used, whereas tissue fibrosis decrease is associated with the concentration and time of intervention. Conclusion

  17. Barium Depletion in Hollow Cathode Emitters

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2009-01-01

    The effect of tungsten erosion, transport and redeposition on the operation of dispenser hollow cathodes was investigated in detailed examinations of the discharge cathode inserts from an 8200 hour and a 30,352 hour ion engine wear test. Erosion and subsequent re-deposition of tungsten in the electron emission zone at the downstream end of the insert reduces the porosity of the tungsten matrix, preventing the ow of barium from the interior. This inhibits the interfacial reactions of the barium-calcium-aluminate impregnant with the tungsten in the pores. A numerical model of barium transport in the internal xenon discharge plasma shows that the barium required to reduce the work function in the emission zone can be supplied from upstream through the gas phase. Barium that flows out of the pores of the tungsten insert is rapidly ionized in the xenon discharge and pushed back to the emitter surface by the electric field and drag from the xenon ion flow. This barium ion flux is sufficient to maintain a barium surface coverage at the downstream end greater than 0.6, even if local barium production at that point is inhibited by tungsten deposits. The model also shows that the neutral barium pressure exceeds the equilibrium vapor pressure of the impregnant decomposition reaction over much of the insert length, so the reactions are suppressed. Only a small region upstream of the zone blocked by tungsten deposits is active and supplies the required barium. These results indicate that hollow cathode failure models based on barium depletion rates in vacuum dispenser cathodes are very conservative.

  18. An experimental study on tissue reaction of various contrast agents on mediastinum

    International Nuclear Information System (INIS)

    Chung, Jin Wook; Kim, Hyung Jin; Kim, Seung Hyup; Park, Jae Hyung; Chang, Kee Hyun

    1989-01-01

    Till now, there is no consensus about appropriate contrast agents for use in clinical investigation in suspected perforation of the esophagus. Gastrografin, most widely used water soluble contrast agent, is less sensitive in detection of fistulous tract and can induce pulmonary edema, leading to death occasionally, if aspirated. Barium sulphate has been contraindicated without actual evaluation of its effect on mediastinum by experimental and clinical study. The purpose of this experimental study is to evaluate the type of tissue reaction and its severity in mediastinum and, as a result, to propose appropriate contrast agents in various clinical situations of suspected esophageal leakage. Barium sulphate, Hytrat, Gastrografin, Telebrix, Hexabrix, Amipaque, Niopam, and Ultravist were injected into mediastinum of 20 rats in each. The tissue reaction of injection sites were examined microscopically and graded according severity of inflammatory reaction with serial follow up from 1 day to 8 weeks after injection. The results are as follows, 1. Barium sulphate and Hytrast produced highly significant (p<0.01) tissue reaction compared to saline group and early inflammatory reaction was more severe in Hytrast. 2. Water soluble agents produced no significant reaction in mediastinum compared to saline control group and proved to be safe in the situation of leakage into mediastinum. 3. Injected barium caused no death during 8 week follow up in spite of large injected amount and histologically produced localized indolent granuloma after 4 weeks which is expected not to cause any delayed complications. In consideration of above results, superior physical characteristics of barium sulphate and drawbacks of Gastrografin, we concluded as follows. 1. For postoperative assessment of esophageal anastomosis, Barium sulphate is the contrast agent of choice

  19. Colonic Tuberculosis Clinically Misdiagnosed as Anorexia Nervosa and Radiologically and Histopathologically as Crohn’s Disease

    Directory of Open Access Journals (Sweden)

    Tariq A Madani

    2002-01-01

    Full Text Available A case of colonic tuberculosis presenting with severe wasting was misdiagnosed as anorexia nervosa at another institution. Double contrast barium enema showed strictures, and ulcerations of the cecum and ascending colon with a skip area. The radiologist believed that these findings were due to Crohn's disease. Colonoscopic biopsies from the involved area revealed histopathological changes typical of Crohn's disease and not tuberculosis. The patient completely recovered with antituberculous therapy without steroids. The case demonstrated the clinical, radiological and histopathological difficulties and misdiagnoses that may be associated with the diagnosis of colonic tuberculosis.

  20. Beer as colon lavage preparation

    International Nuclear Information System (INIS)

    Kinnunen, J.; Linden, H.; Pietilae, J.; Juutilainen, T.

    1987-01-01

    Six patients received beer preparation prior to double contrast barium enema. The beer group scored slightly better (though not statistically significantly) both in the cleanliness and in the mucosal coating of the bowel than the control group with standard preparation. The fluid balance was unaltered. The patients in the beer group felt surprisingly well, likely due to the good fluid and energy balance provided by the beer. The beer preparation could be used in cases, when the patients are ready to intake beer and want to maintain a good nutritional status. (orig.) [de

  1. Improvements in gastric diagnosis by using high density contrast media with low viscosity

    International Nuclear Information System (INIS)

    Toischer, H.P.

    1983-01-01

    In a retrospective clinical study, 150 unselected double contrast examinations of the stomach using conventional contrast media (100 g/100 ml barium sulphate) were compared with a similar number of examinations using a high density contrast medium of flow viscosity (250 g/100 ml barium sulphate). The high density contrast medium was distinctly better for demonstrating detail of the gastric mucosa. The uneveness of coating and instability of the older high density contrast media was observed in 15.5% of cases and, in no instance, did this make it impossible to reach a diagnosis. (orig.) [de

  2. Advanced method of double contrast examination of the stomach

    International Nuclear Information System (INIS)

    Vlasov, P.V.; Yakimenko, V.F.

    1981-01-01

    An advanced method of double contrast examination of the stomach with the use of high concentrated barium suspension is described. It is shown that concentration of barium suspension must be not less than 200 mass/volume per cent to obtain the sharp image of the mucosal microrelief 6 standard position are recommended for the double contrast examination of all stomach walls. 200 patients with different digestive system diseases are examined with the help of developed methods. The sharp image of the mucosal microrelief is obtained in 70% cases [ru

  3. Colo-colic intussusception associated with pneumatosis cystoides intestinalis

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, O.; Daneman, A.; Alton, D.J. [Department of Diagnostic Imaging, Hospital for Sick Children and the University of Toronto, 555 University Avenue, Toronto, Ontario M5G 1X8 (Canada); Thorner, P. [The Division of Pathology, Hospital for Sick Children and the University of Toronto, Toronto (Canada)

    1998-07-01

    This paper describes pneumatosis cystoides intestinalis in association with colo-colic intussusception in a young teenager. The intussusception was easily reduced at barium enema. The recognition of the characteristic filling defects in the barium column facilitates a correct diagnosis. This association has only been reported previously in six adults. (orig.) With 2 figs., 9 refs.

  4. Radiologic diagnosis of Hirschsprung's disease utilizing rectosphincteric reflex

    Energy Technology Data Exchange (ETDEWEB)

    Nagasaki, A.; Ikeda, K.; Hayashida, Y.

    1984-09-01

    Artificial balloon distension of the rectum caused a reflex opening of the anal canal as seen during barium enema in 10 out of 10 normal children and in 7 of 7 children with idiopathic constipation. Reflex opening of the anal canal was not observed in any of 15 children with proven Hirschsprung's disease. This lack of response was independent of the length of aganglionosis or previous diverting colostomy and corresponded to the fact that on manometric study the intraluminal pressure of the anal canal fell in normal children but not in the children with Hirschsprung's disease. This finding greatly improves the reliability of barium enema in the diagnosis of Hirschsprung's disease.

  5. Fluoroscopy-guided hydrostatic reduction of intussusception in infancy: role of pharmacological premedication.

    Science.gov (United States)

    Esposito, Francesco; Ambrosio, Concetta; De Fronzo, Simona; Panico, Maria Rita; D'Aprano, Marilena; Giugliano, Anna Marcella; Noviello, Domenico; Oresta, Patrizia

    2015-06-01

    Intussusception is one of the most common causes of paediatric emergency. Fluoroscopy-guided hydrostatic reduction is a common nonoperative management strategy for the treatment of intussusception. The role of pharmacological premedication in increasing the success rate of hydrostatic reduction is still controversial. The purpose of this study was to verify the presence of a possible correlation between pharmacological premedication and the percentage of hydrostatic reduction of intussusception in paediatric patients. This study considered children with a diagnosis of idiopathic intussusception treated at our hospital between January 2007 and June 2013. One group of patients underwent hydrostatic reduction by barium enema without any preliminary therapy. A second group of patients received pharmacological premedication with both a sedative and an anti-oedematous agent before the procedure. A total of 398 patients were treated with barium enema for therapeutic purposes. In the group of patients who received no premedication (n = 254), 165 (65 %) children achieved hydrostatic reduction of the intussusception. Among the patients who received pharmacological premedication prior to barium enema (n = 144), 122 (85 %) children achieved resolution of the intussusception. Our study shows that the use of pharmacological premedication is effective for the reduction of the intussusception, as its limit patient stress, fluoroscopic time and radiation dose.

  6. Imagenological behaviour in view of intestinal invagination in children under two years of age

    International Nuclear Information System (INIS)

    Morffi Gonzalez, Barbara Evelyn; Gonzalez Coba, Maria Isabel; Quintas Santana, Maria; Lopez Gonzalez, Saray Maria

    2010-01-01

    We performed an observational study with the aim of imaging to determine the behavior of intussusception in children under 2 years at the Provincial Teaching Hospital, Dr. Antonio Luaces Iraola 'Ciego de Avila', in the time period from January 1, 2006 to January 1, 2009. The sample consisted of 18 patients under 2 years with clinical and imaging diagnosis of intussusception treated at the Imaging department. Predominant age group younger than 4 months and the male was predominant topographic presentation ileocolic and idiopathic, ultrasound and radiographic examination was performed at 100% of the patients demonstrated decreased intestinal gas pattern as a dominant sign in simple test, the arrest of Contrast 'crab claws' in the colon by enema and the sign of the 'target' or 'pseudo kidney' in the abdominal ultrasonography, there were 12 surgical and 6 reductions reductions permanent imaging, 4 hydro colonic, with a recurrence and 2 for barium enema

  7. Studies on the usefulness of negative contrast medium for CT-fatty emulsion-in diseases of the gastrointestinal tract

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Tsuneo; Kameda, Kyoko; Tanaka, Koji; Nishimura, Shigeru; Higashide, Toshiaki [Osaka Police Hospital (Japan)

    1983-09-01

    Investigation was made on the usefulness of negative contrast medium for CT-fatty emulsion-, which is applicable to the whole area of the gastrointestinal tract, in diagnoses of diseases of the stomach, pancreas, colon and the organs adjacent to the three. After the administration of the drug, CT was performed and the thickness of the walls were measured for the normal upper gastrointestinal tract in 50 patients and for the normal colon in 25. The normal gastric walls did not exceed 5 mm and the walls of the colon measured about 2.1 mm. Gastric tumors were projected at 80.4%. Especially, the drug was useful for the early diagnosis of schirrus. The pancreas was more clearly projected in 88.4% of the patients. The reconstruction method using the present drug was useful for the investigation of the relationship between the two organs, the stomach and the duodenum, and the pancreas. When CT was performed on a patient laying this right side on the bed, invasion of pancreatic cancer and gastric antrum cancer into the circumferntial organs could be diagnosed. The drug was useful for the identification of tumors in the colon and intrapelvic lesions. The medium was also given to four patients with colitis ulcerosa and the obtained findings on the wall features were same as those obtained by barium enema. The present drug was little associated with side effects and is considered to be an excellent negative contrast medium for all the gastrointestinal tracts.

  8. Barium and iron abundances in red giants

    International Nuclear Information System (INIS)

    Fernandez-Villacanas, J.L.; Rego, M.; Cornide, M.

    1990-01-01

    An intermediate-dispersion abundance analysis has been carried out on a sample of 21 barium and 14 comparison stars. The excess of barium over iron has been used as the most representative indicator of peculiarity. These excesses are higher in the peculiar stars than in the nonpeculiar stars. Particularly interesting is the case of HD 67447, included in the comparison stars, with an excess Ba/Fe abundance = 1.61, probably a new barium star. A trend indicating a possible anticorrelation between barium overabundance and metallicity favors the suggestion that the barium strong group is older than the barium weak one. 36 refs

  9. Radioactive Barium Ion Trap Based on Metal-Organic Framework for Efficient and Irreversible Removal of Barium from Nuclear Wastewater.

    Science.gov (United States)

    Peng, Yaguang; Huang, Hongliang; Liu, Dahuan; Zhong, Chongli

    2016-04-06

    Highly efficient and irreversible capture of radioactive barium from aqueous media remains a serious task for nuclear waste disposal and environmental protection. To address this task, here we propose a concept of barium ion trap based on metal-organic framework (MOF) with a strong barium-chelating group (sulfate and sulfonic acid group) in the pore structures of MOFs. The functionalized MOF-based ion traps can remove >90% of the barium within the first 5 min, and the removal efficiency reaches 99% after equilibrium. Remarkably, the sulfate-group-functionalized ion trap demonstrates a high barium uptake capacity of 131.1 mg g(-1), which surpasses most of the reported sorbents and can selectively capture barium from nuclear wastewater, whereas the sulfonic-acid-group-functionalized ion trap exhibits ultrafast kinetics with a kinetic rate constant k2 of 27.77 g mg(-1) min(-1), which is 1-3 orders of magnitude higher than existing sorbents. Both of the two MOF-based ion traps can capture barium irreversibly. Our work proposes a new strategy to design barium adsorbent materials and provides a new perspective for removing radioactive barium and other radionuclides from nuclear wastewater for environment remediation. Besides, the concrete mechanisms of barium-sorbent interactions are also demonstrated in this contribution.

  10. Radiologic and histopathologic evaluation of various contrast media for bronchography

    International Nuclear Information System (INIS)

    Kang, Eun Young; Hong, Ki Taek; Kim, Jin Hyung; Kim, Hyung Rae; Shin, Bong Kyung; Oh, Yu Whan; Kim, Han Kyeom; Park, Cheol Min; Seol, Hae Young; Cha, In Ho

    1999-01-01

    To determine which contrast media are both efficient and safe for the imaging of airways. We evaluated five contrast media (barium, gastrografin, iotrolan, ioxaglate, iopentol) in terms of image quality and their effects on the lungs of 25 white rabbits. For bronchography 0.5ml of contrast media was used. In each contrast group, HRCT scans were obtained immediately (n=5), 12 hours (n=4), 1 day (n=3), 2 days (n=2), and 1 week (n=1) after bronchography. Histopathologic specimens were obtained immediately, 12 hours, 1 day, 2 days, and 1 week later. Bronchograms were evaluated for image quality by three radiologists working independently, and were scored as 1(poor), 2(moderate), or 3(good) in terms of contrast quality and bronchial coating. HRCT was evaluated by two radiologists who reached a concensus;they determined the presence of contrast media, and then the pattern and extent of pulmonary opacity, and any related changes. Histopatholgic specimens were evaluated by two pathologists who sought consensus as to the extent of inflammation, pulmonary edema, and hemorrhage, and any changes in these aspects. Bronchography indicated that the sum of scores for contrast quality was 45 for barium, 33 for gastrografin, 28 for iotrolan, 30 for ioxaglate, and 28 for iopentol, while for each of these media, the sum of scores for bronchial coating was 39, 19, 25, 23, and 21, respectively. Barium showed the best image quality. In all rabbits, HRCT demonstrated the variable extent of ground-glass attenuation and/or consolidation. Lesions were most extensive at 1-2days and then regressed at 1 week;these HRCT findings correlated well with histologic findings. In histologic studies of all five contrast media groups, variable severe inflammatory reactions were observed, with or without necrosis, congesion, edema, and hemorrhage. It was noted that ioxaglate appeared to cause least tissue reaction. The imaging results of this experimental study indicate that for bronchography, barium is

  11. Ultrasound guided reduction of an ileocolic intussusception by a hydrostatic method by using normal saline enema in paediatric patients: a study of 30 cases.

    Science.gov (United States)

    Digant, Shastri Mona; Rucha, Seth; Eke, Dessai

    2012-12-01

    The conventional hydrostatic reduction of an intussusception with barium enema or the pneumatic reduction of an intussusception is associated with considerable ionizing radiations and a risk of perforation; while the hydrostatic reduction of an intussusception under ultrasound guidance is a very safe method because the whole procedure is visualized with real time ultrasound. Also, being a non-invasive method with a high success rate, this procedure has emerged as a useful alternative to a surgical intervention. The aim of this study was to evaluate the role of ultrasound and colour Doppler studies for the guidance of the hydrostatic reduction of a childhood intussusception by using normal saline. Among 41 children who were evaluated with ultrasonography for the confirmation of the presence of intussusceptions, hydrostatic reduction of intussusception were performed under a sonographic guidance in 30 patients, whereas 11 patients were excluded due to clinical contraindications. This disease was observed mostly at the ages of 6 months to 24 months. In 80% of the patients, there was a recent history of gastroenteritis and 40 % had a history of common cold. The most common site of the intussusception was the transverse colon near the hepatic flexor of the colon (90%), with a mean duration of 22.1±17.3 hours. The overall rate of a successful reduction was 87% and the mean reduction time was 14 minutes. None of the cases showed recurrence within 24 hrs. No complications were observed. We conclude that ultrasound with colour Doppler study is very useful for the diagnosis of intussusceptions, as well as for guided hydrostatic reductions by using normal saline enema. This is an optimal, simple, and a safe procedure for the treatment of intussusceptions in paediatric patients.

  12. Barium inhibits arsenic-mediated apoptotic cell death in human squamous cell carcinoma cells.

    Science.gov (United States)

    Yajima, Ichiro; Uemura, Noriyuki; Nizam, Saika; Khalequzzaman, Md; Thang, Nguyen D; Kumasaka, Mayuko Y; Akhand, Anwarul A; Shekhar, Hossain U; Nakajima, Tamie; Kato, Masashi

    2012-06-01

    Our fieldwork showed more than 1 μM (145.1 μg/L) barium in about 3 μM (210.7 μg/L) arsenic-polluted drinking well water (n = 72) in cancer-prone areas in Bangladesh, while the mean concentrations of nine other elements in the water were less than 3 μg/L. The types of cancer include squamous cell carcinomas (SCC). We hypothesized that barium modulates arsenic-mediated biological effects, and we examined the effect of barium (1 μM) on arsenic (3 μM)-mediated apoptotic cell death of human HSC-5 and A431 SCC cells in vitro. Arsenic promoted SCC apoptosis with increased reactive oxygen species (ROS) production and JNK1/2 and caspase-3 activation (apoptotic pathway). In contrast, arsenic also inhibited SCC apoptosis with increased NF-κB activity and X-linked inhibitor of apoptosis protein (XIAP) expression level and decreased JNK activity (antiapoptotic pathway). These results suggest that arsenic bidirectionally promotes apoptotic and antiapoptotic pathways in SCC cells. Interestingly, barium in the presence of arsenic increased NF-κB activity and XIAP expression and decreased JNK activity without affecting ROS production, resulting in the inhibition of the arsenic-mediated apoptotic pathway. Since the anticancer effect of arsenic is mainly dependent on cancer apoptosis, barium-mediated inhibition of arsenic-induced apoptosis may promote progression of SCC in patients in Bangladesh who keep drinking barium and arsenic-polluted water after the development of cancer. Thus, we newly showed that barium in the presence of arsenic might inhibit arsenic-mediated cancer apoptosis with the modulation of the balance between arsenic-mediated promotive and suppressive apoptotic pathways.

  13. Barium carbonate as an agent to improve the electrical properties of neodymium-barium-copper system at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, J.P. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Duarte, G.W. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Research Group in Technology and Information, Centro Universitário Barriga Verde (UNIBAVE), Santa Catarina, SC (Brazil); Caldart, C. [Post-Graduate Program in Science and Materials Engineering, Universidade do Extremo Sul Catarinense (UNESC), Criciúma, SC, 88806-000 (Brazil); Kniess, C.T. [Post-Graduate Program in Professional Master in Management, Universidade Nove de Julho, São Paulo, SP (Brazil); Montedo, O.R.K.; Rocha, M.R. [Post-Graduate Program in Science and Materials Engineering, Universidade do Extremo Sul Catarinense (UNESC), Criciúma, SC, 88806-000 (Brazil); Riella, H.G. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Fiori, M.A., E-mail: fiori@unochapeco.edu.br [Post-Graduate Program in Environmental Science, Universidade Comunitária da Região de Chapecó (UNOCHAPECÓ), Chapecó, SC, 89809-000 (Brazil); Post-Graduate Program in Technology and Management of the Innovation, Universidade Comunitária da Região de Chapecó (UNOCHAPECÓ), Chapecó, SC, 89809-000 (Brazil)

    2015-11-15

    Specialized ceramics are manufactured under special conditions and contain specific elements. They possess unique electrical and thermal properties and are frequently used by the electronics industry. Ceramics containing neodymium-barium-copper (NBC) exhibit high conductivities at low temperatures. NBC-based ceramics are typically combined with oxides, i.e., NBCo produced from neodymium oxide, barium oxide and copper oxide. This study presents NBC ceramics that were produced with barium carbonate, copper oxide and neodymium oxide (NBCa) as starting materials. These ceramics have good electrical conductivities at room temperature. Their conductivities are temperature dependent and related to the starting amount of barium carbonate (w%). - Highlights: • The new crystalline structure were obtained due presence of the barium carbonate. • The NBCa compound has excellent electrical conductivity at room temperature. • The grain crystalline morphology was modified by presence of the barium carbonate. • New Phases α and β were introduced by carbonate barium in the NBC compound.

  14. Barium carbonate as an agent to improve the electrical properties of neodymium-barium-copper system at high temperature

    International Nuclear Information System (INIS)

    Fernandes, J.P.; Duarte, G.W.; Caldart, C.; Kniess, C.T.; Montedo, O.R.K.; Rocha, M.R.; Riella, H.G.; Fiori, M.A.

    2015-01-01

    Specialized ceramics are manufactured under special conditions and contain specific elements. They possess unique electrical and thermal properties and are frequently used by the electronics industry. Ceramics containing neodymium-barium-copper (NBC) exhibit high conductivities at low temperatures. NBC-based ceramics are typically combined with oxides, i.e., NBCo produced from neodymium oxide, barium oxide and copper oxide. This study presents NBC ceramics that were produced with barium carbonate, copper oxide and neodymium oxide (NBCa) as starting materials. These ceramics have good electrical conductivities at room temperature. Their conductivities are temperature dependent and related to the starting amount of barium carbonate (w%). - Highlights: • The new crystalline structure were obtained due presence of the barium carbonate. • The NBCa compound has excellent electrical conductivity at room temperature. • The grain crystalline morphology was modified by presence of the barium carbonate. • New Phases α and β were introduced by carbonate barium in the NBC compound

  15. Effect of rectal enemas on rectal dosimetric parameters during high-dose-rate vaginal cuff brachytherapy. A prospective trial

    Energy Technology Data Exchange (ETDEWEB)

    Sabater, Sebastia; Andres, Ignacio; Sevillano, Marimar; Berenguer, Roberto; Aguayo, Manuel; Villas, Maria Victoria [Complejo Hospitalario Universitario de Albacete (CHUA), Department of Radiation Oncology, Albacete (Spain); Gascon, Marina; Arenas, Meritxell [Hospital Universitari Sant Joan, Department of Radiation Oncology, Reus (Spain); Rovirosa, Angeles; Camacho-Lopez, Cristina [University of Barcelona, IDIBAPS, Gynecological Cancer Unit, Radiation Oncology Department, ICMHO, Hospital Clinic, Barcelona (Spain)

    2016-04-15

    To evaluate the effects of rectal enemas on rectal doses during postoperative high-dose-rate (HDR) vaginal cuff brachytherapy (VCB). This prospective trial included 59 patients. Two rectal cleansing enemas were self-administered before the second fraction, and fraction 1 was considered the basal status. Dose-volume histogram (DVH) values were generated for the rectum and correlated with rectal volume variation. Statistical analyses used paired and unpaired t-tests. Despite a significant 15 % reduction in mean rectal volume (44.07 vs. 52.15 cc, p = 0.0018), 35.6 % of patients had larger rectums after rectal enemas. No significant rectal enema-related DVH differences were observed compared to the basal data. Although not statistically significant, rectal cleansing-associated increases in mean rectal DVH values were observed: D{sub 0.1} {sub cc}: 6.6 vs. 7.21 Gy; D{sub 1} {sub cc}: 5.35 vs. 5.52 Gy; D{sub 2} {sub cc}: 4.67 vs. 4.72 Gy, before and after rectal cleaning, respectively (where D{sub x} {sub cc} is the dose to the most exposed x cm {sup 3}). No differences were observed in DVH parameters according to rectal volume increase or decrease after the enema. Patients whose rectal volume increased also had significantly larger DVH parameters, except for D{sub 5} {sub %}, D{sub 25} {sub %}, and D{sub 50} {sub %}. In contrast, in patients whose rectal volume decreased, significance was only seen for D{sub 25} {sub %} and D{sub 50} {sub %} (D{sub x} {sub %} dose covering x % of the volume). In the latter patients, nonsignificant reductions in D{sub 2} {sub cc}, D{sub 5} {sub cc} and V{sub 5} {sub Gy} (volume receiving at least 5 Gy) were observed. The current rectal enemas protocol was ineffective in significantly modifying rectal DVH parameters for HDR-VCB. (orig.) [German] Beurteilung der Auswirkungen von rektalen Dosen waehrend postoperativer High-Dose-Rate-(HDR-)Brachytherapie an der Scheidenmanschette (''vaginal cuff brachytherapy'', VCB). An

  16. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  17. Barium aspiration and alveolarisation of barium in an infant: A case report and review of management

    Directory of Open Access Journals (Sweden)

    Alan F. Isles

    2014-05-01

    Full Text Available We describe a case of bilateral inhalation and alveolarisation of barium in an infant following a barium swallow for investigation of dusky spells associated with feeds. A bronchoscopy subsequently revealed the presence of a mid-tracheal tracheo-oesophageal cleft. We review the literature on barium aspiration, its consequences and make recommendations for management.

  18. CBED contrast in the lower order Laue zone

    International Nuclear Information System (INIS)

    Rossouw, C.J.; Maunders, C.J.; Whitfield, H.J.; Etheridge, J.

    2006-01-01

    Contrast in a systematic arrangement of lower order Laue zone (LOLZ) beams is reported and analysed using a Bloch wave description. Observations are reported for hexagonal barium ruthenium zirconate (Ba 4 Ru 3 ZrO 12 ) and barium ruthenium titanate (Ba 3 Ti 2 RuO 9 ), both near the c -axis orientation. The specific scattering dynamics invoked by this diffraction geometry may have novel uses in the exploration of crystallographic parameters

  19. Assessment of radiation dose due to fluoroscopic procedures in patients at some selected facilities in the Greater Accra Region, Ghana

    International Nuclear Information System (INIS)

    Gyasi, E.

    2013-07-01

    Radiation doses to 182 adults patients who underwent barium enema, barium meal, barium swallow, myelogram, hysterosalpingography and urethrogram examination collectively at facilities A and B were investigated. Radiation dose was measured using kerma-area-product (KAP) meter. From the KAP readings, patient's data and other relevant information from the control console, effective dose and selective organ doses were estimated using Monte Carlo program software (PCXMC version 1.5). Quality control tests performed on the two fluoroscopy machines were found to be within the acceptance criteria. Mean effective doses were found to be 8.45 ± 0.38mSv, 7.628 ± 0.42 mSv, 1.46 ± 0.13 mSv, 2.02 ± 0.16 mSv, 0.32 ± 0.03 mSv for barium enema, barium meal, barium swallow, myelogram and urethrogram examinations respectively at Facility A. At Facility B the mean effective dose were found to be 4.12 ± 0.15 mSv, 1.83 ± 0.10 mSv, 0.81 ± 0.04 mSv, 0.53 ± 0.036 mSv and 0.27 ± 0.01 mSv for barium enema, barium meal, barium swallow, myelogram, hysterosalpingography and urethrogram examination respectively. Thymus received the highest organ dose of 29.19± 2.07mGy during barium meal studies at Facility A of all the procedures in the two hospitals. Magnitude of organ doses was observed to to be in relation with the closeness to or in the direction of the primary beam of radiation. Organ and effective doses from Facility A were relatively higher than those from Facility B in comparison by a factor of a about 2 with the exception of the barium meal examination at Facility A which was by a factor of about 4. The measured KAP readings fro the two facilities were below the international accepted reference levels with the exception of barium meal examination at Facility A which recorded a higher value of 25.96 ± 1.83 Gy.cm 2 as compared to ICRP (2001) reference value of 25 Gy.cm 2 . Longer radiation beam on time, high number of radiographs taken per patient, wide exposure beam area on

  20. Radiographic, Hematologic and Biochemical Alterations in Peritoneal Fluid after Intraperitoneal Injection of Barium Sulfate and Gastrografin in Rabbit

    Directory of Open Access Journals (Sweden)

    Sardar Jafari-Shoorijeh

    2012-07-01

    Full Text Available Background: Evaluation of contrast-induced changes in the peritoneal area may reveal the effects of their permeation followed by gastrointestinal perforation. This study aims to compare the radiographic changes and hematological and biochemical parameters of peritoneal fluid and blood after intraperitoneal injection of barium sulfate and gastrografin to the rabbit.Materials and Methods: In this clinical trial, 15 healthy male rabbits were randomly divided into 3 groups. Respectively to each group 10 ml/kg barium sulfate 30%, 10 ml/kg gastrografin, and 10 ml/kg saline was intraperitoneally injected. Before injection and 24 hours after injection, blood samples and peritoneal fluid were collected to measure glucose, total protein, WBC count and pH. Lateral and dorsal-ventral radiography was provided 20 min and 24 hours after contrast injection.Results: After injection of barium sulfate, serum glucose decreased, cell count and blood neutrophil percentage increased, glucose and the percentage of peritoneal fluid lymphocytes decreased (p<0.05. The amount of total protein, cell count and peritoneal fluid neutrophil percentage increased (p<0.05. Gastrografin injection only increased peritoneal fluid total protein (p=0.04. Other blood factors and peritoneal fluid showed no significant changes. In radiographies, barium sulfate remained in abdominal area and rapid absorption of gastrografin was observed.Conclusion: The use of gastrografin has fewer side effects than barium sulfate and is recommended in patients suspected with gastrointestinal perforation.

  1. Statistical properties of barium stars

    International Nuclear Information System (INIS)

    Hakkila, J.E.

    1986-01-01

    Barium stars are G- and K-giant stars with atmospheric excesses of s-process elements, and a broadband spectral depression in the blue portion of the spectrum. The strength of the λ4554 Ball line is used as a classification parameter known as the Barium Intensity. They have a mean absolute magnitude of 1.0 and a dispersion of 1.2 magnitudes (assuming a Gaussian distribution in absolute magnitude) as measured from secular and statistical parallaxes. These stars apparently belong to a young-disk population from analyses of both the solar reflex motion and their residual velocity distribution, which implies that they have an upper mass limit of around three solar masses. There is no apparent correlation of barium intensity with either luminosity or kinematic properties. The barium stars appear to be preferentially distributed in the direction of the local spiral arm, but show no preference to associate with or avoid the direction of the galactic center. They do not appear related to either the carbon or S-stars because of these tendencies and because of the stellar population to which each type of star belongs. The distribution in absolute magnitude combined with star count analyses implies that these stars are slightly less numerous than previously believed. Barium stars show infrared excesses that correlate with their barium intensities

  2. 6-year-old girl with anorectal malformation: what is more important – anatomy or function?

    Directory of Open Access Journals (Sweden)

    Dmitry A. Morozov

    2018-02-01

    Full Text Available 6-year-old girl with first revealed anorectal malformation with perineal fistula was investigate. She did not have any complaints or history of constipation/soiling. Resting and squeeze anal pressure by anorectal manometry was normal. Recto-anal inhibitory reflex registered. There was no signs of dyssynergic defecation. The diameter of the colon by contrast enema was normal, megarectum did not detect, barium all came out after defecation. Muscles electro-identification confirmed external anal sphincter located posterior to the anus. After examination, council for Pediatric Surgery decided not to perform the surgery. Monitoring of the patient continued.

  3. Investigation of X-ray permeability of surgical gloves coated with different contrast agents

    Science.gov (United States)

    Kayan, Mustafa; Yaşar, Selçuk; Saygın, Mustafa; Yılmaz, Ömer; Aktaş, Aykut Recep; Kayan, Fatmanur; Türker, Yasin; Çetinkaya, Gürsel

    2016-01-01

    Objective: We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. Methods: The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL), 10% povidone–iodine (PV–I), 240/240 g/mL barium sulphate and a mixture of equal amounts of all contrast agents. A radiation dose detector was placed in coated latex gloves for each one. The absorption values of radiation from latex gloves coated with various contrast agents were measured and compared with the absorption of radiation from lead gloves. This study was designed as an ‘experimental study’. Results: The mean absorption value of X-ray from lead gloves was 3.0±0.08 µG/s. The mean absorption values of X-ray from latex gloves coated with various contrast agents were 3.7±0.09 µG/s (iopromide 370/100 mg I/mL), 3.6±0.09 µG/s (iomeprol 400/100 mg I/mL), 3.7±0.04 µG/s (PV–I), 3.1±0.07 µG/s (barium sulphate) and 3.8±0.05 µG/s (mixture of all contrast agents). Latex gloves coated with barium sulphate provided the best radiation absorption compared with latex gloves coated with other radiodense contrast agents. Conclusion: Latex gloves coated with barium sulphate may provide protection equivalent to lead gloves. PMID:26680548

  4. An experimental study on radiological examination of obstructed small bowel with various contrast media

    International Nuclear Information System (INIS)

    Lee, Yong; Kim, Sung Jin; Han, Moon Hee; Park, Jae Hyung

    1991-01-01

    For the evaluation of the level and cause of small bowel obstruction, an oral barium study is usually chosen. When perforation is whether barium or a water-soluble contrast agent should be used, because barium causes from foreign body reactions as well as adhesions in the extraluminal tissues. Water-soluble contrast agent, on the other hand, are less satisfactory but in general have no untoward effects in the extraluminal tissues. Because of hyperosomolarity, water-soluble contrast agents attract large amounts of fluid with subsequent dilution and loss of contrast and pose a risk of pulmonary edema if aspirated. The use of the newer non-ionic and low-osmolarity water-soluble contrast will likely avoid pulmonary complications due to aspiration. The author performed this experimental study to compare the radiological efficacy of different contrast media in enteric follow-through examinations of obstructed small bowel. Rate had a ligature applied to the distal ileum via laparotomy. Four contrast media were subjected to testing by instillation via oro-gastric tube immediately after laparotomy. Radiographs were exposed at 1, 4 and 8 hours and evaluated later. After 24 hours the animals were sacrificed and the stomach and small bowels, free from mesentery and omental tissue, were weighted with contrasts. The progression in the bowel was proportionate to the osmolarity of the contrast media. After 1 hour, the observations indicated sodium diatrizoate (Gastrografin, Schering) to be the least favorable medium with respect to sharpness of the mucosal border. After 8 hours, barium gave a poorer delineation compared to Ioxaglate (Hexabric, Guerbet) and Iopromide (Ultravist, Schering). Early deaths were noted in the sodium diatrizoate and ioxaglate groups. So we conclude that when using a rather high-volume bolus, low-osmolar non-ionic contrast media seem to have significant prospects for general diagnostic use in patients with suspected intestinal obstruction

  5. A scintigraphic study of colostomy irrigation

    Energy Technology Data Exchange (ETDEWEB)

    Yasuda, Shinji; Fujii, Hisao; Nakano, Hiroshige (Nara Medical Univ., Kashihara (Japan))

    1991-09-01

    Colostomy irrigation was investigated by colonoscintigraphy. Twelve rectal cancer and one sigmoid colon cancer patients were examined. The tepid water whose volume was determined by barium enema was mixed with {sup 99m}Tc-DTPA. Dynamic scanning was started on commencement of colostomy irrigation. The sampling time was 3 seconds and scanning was performed for 30 minutes. The mean volume of remnant colon as measured by barium enema was 650 ml. The mean number of mass movements was 4.3. The mean evacuation time was 11 minutes 56 seconds and the mean half emptying time was calculated to be 9.5 minutes. The evacuation time in the patients who underwent colostomy irrigation for more than 2 years was greater than that in the patients who underwent irrigation for less than 2 years. Colonic motility was thought to have weakened. The half emptying time and the number of mass movements in the patients whose irrigation water went into the terminal ileum was more than that in the patients whose irrigation water was within the colon and cecum. Irrigation water which went into the terminal ileum was caused evacuation after the contents of the remnant colon were washed out. In conclusion, patients should have their colostomy irrigated with the tepid water, volume is determined by barium enema. Furthermore single infusion of the water is recommended. (author).

  6. A scintigraphic study of colostomy irrigation

    International Nuclear Information System (INIS)

    Yasuda, Shinji; Fujii, Hisao; Nakano, Hiroshige

    1991-01-01

    Colostomy irrigation was investigated by colonoscintigraphy. Twelve rectal cancer and one sigmoid colon cancer patients were examined. The tepid water whose volume was determined by barium enema was mixed with 99m Tc-DTPA. Dynamic scanning was started on commencement of colostomy irrigation. The sampling time was 3 seconds and scanning was performed for 30 minutes. The mean volume of remnant colon as measured by barium enema was 650 ml. The mean number of mass movements was 4.3. The mean evacuation time was 11 minutes 56 seconds and the mean half emptying time was calculated to be 9.5 minutes. The evacuation time in the patients who underwent colostomy irrigation for more than 2 years was greater than that in the patients who underwent irrigation for less than 2 years. Colonic motility was thought to have weakened. The half emptying time and the number of mass movements in the patients whose irrigation water went into the terminal ileum was more than that in the patients whose irrigation water was within the colon and cecum. Irrigation water which went into the terminal ileum was caused evacuation after the contents of the remnant colon were washed out. In conclusion, patients should have their colostomy irrigated with the tepid water, volume is determined by barium enema. Furthermore single infusion of the water is recommended. (author)

  7. [Elective laparoscopic right colectomy for caecal volvulus: case report and literature review].

    Science.gov (United States)

    Ramírez-Ramírez, Moisés Marino; Villanueva-Sáenz, Eduardo; Ramírez-Wiella-Schwuchow, Gustavo

    Caecal volvulus is an uncommon cause of intestinal obstruction. Its clinical presentation is non-specific, with the diagnosis usually confirmed by barium enema and abdominal computed tomography. Treatment depends on many factors, and minimally invasive approaches are becoming the treatment of choice. A 54 years old female, admitted to the Emergency Department with clinical symptoms of intestinal obstruction. On physical examination she had a palpable, firm, and tympanitic mass in the right abdomen, with peritoneal irritation. The radiographs of the abdomen, barium enema and abdominal computed tomography showed caecal volvulus. As she showed a full remission after the barium enema, with no clinical or biochemical data of systemic inflammatory response syndrome or peritoneal irritation, she was discharged to her home. Two weeks later, a laparoscopic right hemicolectomy was performed with an ileo-transverse extracorporeal anastomosis. Her progress was satisfactory, and she was discharged 4 days after surgery due to improvement. Caecal volvulus is a rare cause of intestinal obstruction, with high mortality rates, and is caused by excessive mobility of the caecum. Its incidence is increasing. Treatment depends on many factors. Early non-surgical untwisting, followed by an elective laparoscopic surgical procedure offers several advantages and reduces mortality. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  8. Self-Administered Ethanol Enema Causing Accidental Death

    Directory of Open Access Journals (Sweden)

    Thomas Peterson

    2014-01-01

    Full Text Available Excessive ethanol consumption is a leading preventable cause of death in the United States. Much of the harm from ethanol comes from those who engage in excessive or hazardous drinking. Rectal absorption of ethanol bypasses the first pass metabolic effect, allowing for a higher concentration of blood ethanol to occur for a given volume of solution and, consequently, greater potential for central nervous system depression. However, accidental death is extremely rare with rectal administration. This case report describes an individual with klismaphilia whose death resulted from acute ethanol intoxication by rectal absorption of a wine enema.

  9. Costs of Finding an Advanced Adenoma in Colorectal Screening

    Directory of Open Access Journals (Sweden)

    Jerome B Simon

    2004-01-01

    Full Text Available The authors used computerized decision analysis to estimate the costs of finding and removing an advanced colonic adenoma in patients referred because of a positive fecal occult blood test. An advanced adenoma was defined as a villous adenoma, a tubular adenoma 10 mm or more in size, or a lesion that harboured highgrade dysplasia or cancer. Four strategies were compared: flexible sigmoidoscopy, flexible sigmoidoscopy plus air contrast barium enema, virtual colonoscopy (CT colography and colonoscopy. Colonoscopy with polypectomy was undertaken if any of the methods detected a polyp. Probabilities and test characteristics were determined from the literature, and costs were estimated from the provincial fee schedule (Ontario and local hospital sources. With an assumed 17% probability of an advanced adenoma being present, sigmoidoscopy was the most cost effective strategy at $1930 to find and clear an advanced lesion, but the procredure missed between one-third and almost one-half of the lesions, depending on the depth of insertion. At $2290, colonoscopy was slightly more expensive than sigmoidoscopy and more cost effective than either sigmoidoscopy plus barium enema ($2840 or virtual colonoscopy ($3681, neither of which detected as many advanced adenomas. The authors concluded that colonoscopy is the preferred investigative strategy and that improved access to colonoscopy is an important goal for occult blood screening programs.

  10. Improved radiological diagnosis in the stomach by means of an improved contrast material

    International Nuclear Information System (INIS)

    Lotz, W.; Liebenow, S.

    1979-01-01

    Our experience with a cheap contrast medium, which we prepare ourselves, is described, stretching over a period of 18 months. It is based on the bubbly barium first described by Op den Orth and is made by means of carbone dioxide in a soda water syphon. It is better for detailed contrast examination of the stomach than the commercially available contrast media. It is thought that this is due to optimal viscosity for wetting of the mucosa, optimal size of the barium sulphate particles, which are larger than one micron, and greater distension of the stomach due to greater quantities of CO 2 . The use of bubbly barium for routine examination of the stomach, using double contrast and hypotonia with graded compresseion, almost always results in demonstration of the areae gastricae in large parts of the stomach. We regard this as a sign of a good examination, since we are then able to demonstrate small lesions such as complete or incomplete erosions, ulcer scars of flat ulcers. (orig.) [de

  11. Bacterial Reduction Of Barium Sulphate By Sulphate-Reducing Bacteria

    Directory of Open Access Journals (Sweden)

    Luptáková Alena

    2015-12-01

    Full Text Available Acid mine drainage (AMD is a worldwide problem leading to contamination of water sources. AMD are characterized by low pH and high content of heavy metals and sulphates. The barium salts application presents one of the methods for the sulphates removing from AMD. Barium chloride, barium hydroxide and barium sulphide are used for the sulphates precipitation in the form of barium sulphate. Because of high investment costs of barium salts, barium sulphide is recycled from barium sulphate precipitates. It can be recycled by thermic or bacterial reduction of barium sulphate. The aim of our study was to verify experimentally the possibility of the bacterial transformation of BaSO4 to BaS by sulphate-reducing bacteria. Applied BaSO4 came from experiments of sulphates removal from Smolnik AMD using BaCl2.

  12. Barium aluminate cement: its application

    International Nuclear Information System (INIS)

    Drozdz, M.; Wolek, W.

    1975-01-01

    The technology of manufacturing barium aluminate cement from barium sulfate and alumina, using a rotary kiln for firing the clinker is described. The method of granulation of the homogenized charge was used. Conditions of using the ''to mud'' method in industry were indicated. The physical and chemical properties of barium aluminate cement are determined and the quality of several batches of cement prepared on a semi-industrial scale and their suitability for making highly refractory concretes are tested. The optimal composition of the concretes is determined as a function of the mixing water and barium aluminate cement contents. Several experimental batches of concretes were used in the linings of furnaces in the steel industry. The suitability of these cements for use in fields other than steelmaking is examined. It is established that calcium aluminate cement has certain limited applications [fr

  13. Edge detection of barium-filled stomach picture by one-dimensional collation method

    International Nuclear Information System (INIS)

    Nakamura, Shizuo

    1983-01-01

    The method for the contour edge detection of barium- filled stomach pictures by X-ray for the automatic screening is described using computer technique. It is necessary for the automatic screening of barium- filling pictures to detect accurately the outline of stomachs because the analysis of repletion pictures is performed by checking the disorder of marginal contours and abnormal stomach shapes. However, the detection of the coutour lines is difficult to be successful for the reason that the contrast of stomach pictures to background is low, a stomach is not necessarily filled completely with barium and the shadow of barium flowing into intestines is superimposed on stomach images and the shading is likely to occur. The engineering processing against these problems is not yet solved. In order to reduce the noise due to differential operator, the proposed method determines the boundary of a thing generally by the threshold value of density, and defines the edge of the thing from the differential waveform of density in the vicinity of the boundary. In addition, the method corrects the detection error caused by the local nonconformity of parameters by comparing the edges between the adjacent lines. As a result, in spite of its simple algorithm, the edges with good continuity and less noise can be detected, and the method is not much affected by shading. This method was found to be applicable to the images of others than stomachs. The extraction of the contour of barium- filling pictures requires the high level recognition processing instead of the simple conditioning. (Wakatsuki, Y.)

  14. Analysis of barium by isotope mass spectrometry

    International Nuclear Information System (INIS)

    Long Kaiming; Jia Baoting; Liu Xuemei

    2004-01-01

    The isotopic abundance ratios for barium at sub-microgram level are analyzed by thermal surface ionization mass spectrometry (TIMS). Rhenium trips used for sample preparation are firstly treated to eliminate possible barium background interference. During the preparation of barium samples phosphoric acid is added as an emitting and stabilizing reagent. The addition of phosphoric acid increases the collection efficiency and ion current strength and stability for barium. A relative standard deviation of 0.02% for the isotopic abundance ratio of 137 Ba to 138 Ba is achieved when the 138 Ba ion current is (1-3) x 10 -12 A. The experimental results also demonstrate that the isotope fractionation effect is negligibly small in the isotopic analysis of barium

  15. Oesophageal motility disorders - diagnosis with a barium-rice study

    International Nuclear Information System (INIS)

    Schwickert, H.C.; Schadmand-Fischer, S.; Klose, P.; Staritz, M.; Ueberschaer, B.; Thelen, M.

    1993-01-01

    The purpose of this study was to evaluate the role of a 'barium-rice' study for diagnosis of dysphagia and oesophageal motility disorders. Material and methods: 203 patients with oesophageal motility disorders of various aetiologies were examined by both conventional barium study and a 'barium-rice' study. During the latter, oesophageal clearance of a defined mixture of barium sulfate and boiled rice was measured. Results: The conventional barium study revealed prolonged transit time in only 15.8% (32 of 203 cases), whereas barium-rice study was pathological in 50.8% (103 of 203 cases). In 71 of 171 patients (41.5%) with a normal barium study, barium-rice passage was prolonged. In 23 patients, radiological results were confirmed by manometric measurements. Conclusion: Oesophageal motility disorders are detected by a barim-rice study with high sensitivity independent of the underlying disease. The barium-rice study offers a simple diagnostic tool revealing quantitative and reliable results. The barium-rice study is a suitable method for screening and follow-up of patients with dysphagia and oesophageal motility disorders. (orig.) [de

  16. Use of 3-dimensional computed tomography to detect a barium-masked fish bone causing esophageal perforation.

    Science.gov (United States)

    Tsukiyama, Atsushi; Tagami, Takashi; Kim, Shiei; Yokota, Hiroyuki

    2014-01-01

    Computed tomography (CT) is useful for evaluating esophageal foreign bodies and detecting perforation. However, when evaluation is difficult owing to the previous use of barium as a contrast medium, 3-dimensional CT may facilitate accurate diagnosis. A 49-year-old man was transferred to our hospital with the diagnosis of esophageal perforation. Because barium had been used as a contrast medium for an esophagram performed at a previous hospital, horizontal CT and esophageal endoscopy could not be able to identify the foreign body or characterize the lesion. However, 3-dimensional CT clearly revealed an L-shaped foreign body and its anatomical relationships in the mediastinum. Accordingly, we removed the foreign body using an upper gastrointestinal endoscope. The foreign body was the premaxillary bone of a sea bream. The patient was discharged without complications.

  17. Barite (Barium)

    Science.gov (United States)

    Johnson, Craig A.; Piatak, Nadine M.; Miller, M. Michael; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Barite (barium sulfate, BaSO4) is vital to the oil and gas industry because it is a key constituent of the mud used to drill oil and gas wells. Elemental barium is an additive in optical glass, ceramic glazes, and other products. Within the United States, barite is produced mainly from mines in Nevada. Imports in 2011 (the latest year for which complete data were available) accounted for 78 percent of domestic consumption and came mostly from China.Barite deposits can be divided into the following four main types: bedded-sedimentary; bedded-volcanic; vein, cavity-fill, and metasomatic; and residual. Bedded-sedimentary deposits, which are found in sedimentary rocks with characteristics of high biological productivity during sediment accumulation, are the major sources of barite production and account for the majority of reserves, both in the United States and worldwide. In 2013, China and India were the leading producers of barite, and they have large identified resources that position them to be significant producers for the foreseeable future. The potential for undiscovered barite resources in the United States and in many other countries is considerable, however. The expected tight supply and rising costs in the coming years will likely be met by increased production from such countries as Kazakhstan, Mexico, Morocco, and Vietnam.Barium has limited mobility in the environment and exposed barium in the vicinity of barite mines poses minimal risk to human or ecosystem health. Of greater concern is the potential for acidic metal-bearing drainage at sites where the barite ores or waste rocks contain abundant sulfide minerals. This risk is lessened naturally if the host rocks at the site are acid-neutralizing, and the risk can also be lessened by engineering measures.

  18. Binding and leakage of barium in alginate microbeads.

    Science.gov (United States)

    Mørch, Yrr A; Qi, Meirigeng; Gundersen, Per Ole M; Formo, Kjetil; Lacik, Igor; Skjåk-Braek, Gudmund; Oberholzer, Jose; Strand, Berit L

    2012-11-01

    Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. Copyright © 2012 Wiley Periodicals, Inc.

  19. Time of fluoroscopy and number of gastrointestinal tract by doctors in the ten years. On the annual transition of patients, age groups and risks

    International Nuclear Information System (INIS)

    Iba, Shozo; Hirose, Kouichi; Hirano, Masato; Kawarada, Akira; Futami, Tsutomu.

    1997-01-01

    On the period ranging from May, 1986 to March, 1996. We investigated the actual conditions by doctors on the time while examining by X-ray fluoroscopy and the number of radiograph for the gastrointestinal tract examination using barium contrast medium. The time of fluoroscopy and the number of radiograph per X-ray examination of the stomach were about 8.5 minutes, 25 radiographs. On the patients of examination of barium enema were about 11 minutes, 19 radiographs. The time of fluoroscopy and the number of radiograph for diagnosis, there are observed the difference in the average value of several years. The time of fluoroscopy and the number of radiograph for X-ray examination of stomach by doctors have not always seen decreasing in proportion to their experience. We were estimated somatic individual risks from X-ray examination of gastrointestinal tract using a human body phantom. (author)

  20. Efficacy and Safety of Combined Oral and Enema Therapy Using Polyethylene Glycol 3350-Electrolyte for Disimpaction in Pediatric Constipation.

    Science.gov (United States)

    Yoo, Taeyeon; Bae, Sun Hwan

    2017-12-01

    We evaluated the efficacy and safety of combined oral and enema therapy using polyethylene glycol (PEG) 3350 with electrolyte solution for disimpaction in hospitalized children. We retrospectively studied 28 children having functional constipation who received inpatient treatment between 2008 and 2016. The amount of oral PEG 3350 electrolyte solution administered was 50-70 mL/kg/d (PEG 3350, 3-4.1 g/kg/d), and an enema solution was administered 1-2 times a day as a single dose of 15-25 mL/kg (PEG 3350, 0.975-1.625 g/kg/d). A colon transit time (CTT) test based on the Metcalf protocol was performed in some patients. Administration of oral and enema doses of PEG 3350 electrolyte solution showed 2.1±0.3 times and 2.9±0.4 times, respectively. After disimpaction, the frequency of defecation increased from 2.2±0.3 per week to once a day (1.1±0.1 per day). The number of patients who complained of abdominal pain was reduced from 15 (53.6%) to 4 (14.3%). Before hospitalization, nine patients underwent a CTT test, and 5 of 9 patients (55.6%) were classified as belonging to a group showing abnormalities. And in some patients, mild adverse effects were noted. We examined electrolytes and osmolality before and after disimpaction in 16 of 28 patients, and no abnormalities were noted. In terms of therapeutic efficacy and safety, combined oral and enema therapy using high-dose PEG 3350 with electrolytes is considered superior to conventional oral monotherapy or combined oral and enema therapy on an outpatient basis.

  1. Enemas, suppositories and rectal stimulation are not effective in accelerating enteral feeding or meconium evacuation in low-birthweight infants: a systematic review.

    Science.gov (United States)

    Kamphorst, Kim; Sietsma, Ydelette; Brouwer, Annemieke J; Rood, Paul J T; van den Hoogen, Agnes

    2016-11-01

    Early full enteral feeding in preterm infants decreases morbidity and mortality. Our systematic review covered the effectiveness of rectal stimulation, suppositories and enemas on stooling patterns and feeding tolerance in low-birthweight infants born at up to 32 weeks. It comprised seven studies published between 2007 and 2014 and covered 495 infants. Suppositories were ineffective in shortening the time to reach full enteral feeding, and the evidence on enemas was contradictory. Enemas and rectal stimulation did not shorten the time until complete meconium evacuation was reached. Further research into safe, effective interventions to accelerate meconium excretion is needed. ©2016 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  2. Bronchography in dogs. Comparative study with two barium sulphate solutions

    International Nuclear Information System (INIS)

    Thibaut, J.; Gallardo, P.; Vargas, L.; Deppe, R.; Born, R.

    1998-01-01

    Two solutions of barium sulphate, 60 and 30% w/v, were compared with the ''overflow'' Bronchographic method. Two groups of eight healthy adult does of both sexes, weighing 7 to 18 kg were used for the study. The dogs were anaesthetised with thiopentone sodium 2% (20 mg/kg iv). After intubation, each dog received contrast medium by a catheter connected to a syringe, in a 9 mi dose. Two series of two x-rays plates were taken in left lateral recumbent, 3 and 6 min after administering the contrast medium and in ventrodorsal projection, 30 sec. later. The x-ray plates obtained were analysed and compared intra and inter group considering the advance speed of the contrast medium, the radiographic density and outlines. Adverse reactions were controlled

  3. 'Twisted tape sign': Its significance in recurrent sigmoid volvulus

    Energy Technology Data Exchange (ETDEWEB)

    Gopal, K. [Tameside and Glossop Acute Services NHS Trust, Fountain Street, Ashton-under-Lyne OL6 9RW (United Kingdom)]. E-mail: karthikgopal73@yahoo.co.uk; Lim, Y. [Tameside and Glossop Acute Services NHS Trust, Fountain Street, Ashton-under-Lyne OL6 9RW (United Kingdom); Banerjee, B. [Tameside and Glossop Acute Services NHS Trust, Fountain Street, Ashton-under-Lyne OL6 9RW (United Kingdom)

    2005-11-01

    Aim: Sigmoid volvulus is a common cause of intestinal obstruction in the elderly. Mild attacks of sigmoid volvulus may be more difficult to diagnose due to the lack of severity of symptoms which may resolve spontaneously only to recur after an interval. This study was a review of patients to assess the incidence of the 'twisted tape sign' and to evaluate the significance of its presence in cases of recurrent sigmoid volvulus. Methods and materials: A retrospective study over eight years revealed six cases of surgically confirmed recurrent sigmoid volvulus. Case records and barium enemas of all patients were reviewed. Results: Six patients were identified, including four men and two women, with a median age of 56 years. Diagnostic difficulties were encountered in four (67%) patients with a delay ranging between 10 and 37 months with a mean 17.3 months. Twisted tape sign was confirmed on all barium examinations retrospectively. Conclusion: Recognition of twisted tape sign on barium enema examination along with an appropriate clinical history would suggest a diagnosis of recurrent sigmoid volvulus.

  4. 'Twisted tape sign': Its significance in recurrent sigmoid volvulus

    International Nuclear Information System (INIS)

    Gopal, K.; Lim, Y.; Banerjee, B.

    2005-01-01

    Aim: Sigmoid volvulus is a common cause of intestinal obstruction in the elderly. Mild attacks of sigmoid volvulus may be more difficult to diagnose due to the lack of severity of symptoms which may resolve spontaneously only to recur after an interval. This study was a review of patients to assess the incidence of the 'twisted tape sign' and to evaluate the significance of its presence in cases of recurrent sigmoid volvulus. Methods and materials: A retrospective study over eight years revealed six cases of surgically confirmed recurrent sigmoid volvulus. Case records and barium enemas of all patients were reviewed. Results: Six patients were identified, including four men and two women, with a median age of 56 years. Diagnostic difficulties were encountered in four (67%) patients with a delay ranging between 10 and 37 months with a mean 17.3 months. Twisted tape sign was confirmed on all barium examinations retrospectively. Conclusion: Recognition of twisted tape sign on barium enema examination along with an appropriate clinical history would suggest a diagnosis of recurrent sigmoid volvulus

  5. Efficacy and Safety of Gwakhyangjeonggi-San Retention Enema in Normal Rats and Spontaneously Hypertensive Rats

    Directory of Open Access Journals (Sweden)

    Eunyoung Song

    2013-01-01

    Full Text Available The purpose of this study is to establish a protocol of retention-enema experiments and evaluate the antihypertensive effect and the safety of Gwakhyangjeonggi-san retention enema. Normal and spontaneously hypertensive rats (SHRs were divided into treatment and control groups, respectively. We applied the Gwakhyangjeonggi-san extract by decoction and 0.9% NaCl in each group, estimated the blood pressure and body weight, and performed HPLC analysis. ALT, AST, BUN, and creatinine were examined. The systolic blood pressure within each group in normal rats differed significantly in time effect, and so did the diastolic blood pressure in the treatment group of normal rats. The systolic, diastolic, and mean blood pressure showed significant differences in group effect in the treatment group of the SHRs. The time effect of the body weight in both groups of normal rats differed significantly, so did group × time and time effects in both groups of SHRs. AST, ALT, BUN, and creatinine showed no significant difference between groups. We concluded that the Gwakhyangjeonggi-san retention enema has a hypotensive effect in normal rats within the regular range of blood pressure, but an antihypertensive effect in SHRs. Also, the intervention is safe and does not affect the liver and kidney functions in normal rats.

  6. INFLUENCE OF BARIUM OXIDE ADDITIONS ON PORTLAND CLINKER

    Directory of Open Access Journals (Sweden)

    Anezka Zezulova

    2016-12-01

    Full Text Available Nowadays, nuclear power plants are widespread around the world and research is of great interest. Together with nuclear research, shielding of different types of radiation is an important current topic of research aiming at their safety. Portland cement has been an elementary building material for centuries. Since barium is very efficient in shielding different types of radiation, it can be assumed that the radiation shielding capability of cement can be improved by incorporation of barium. This work deals with the influence of barium oxide, added in the form of barium carbonate and sulphate, on the formation and properties of Portland clinker. The structure of burnt clinkers and the ratio of clinker phases were studied by polarizing microscopy and by X-ray diffraction. With increasing barium content, the alite-belite ratio decreases and the content of free lime gradually increases. Moreover, sulphates induce the growth of alite crystals. The ability of barium to be a part of the clinker minerals was observed by scanning electron microscopy. Belite and clinker melt contain the highest amount of barium, but aggregates of barium oxide are formed in the clinker melt. Furthermore, the rate of alite crystallization was studied under isothermal conditions.

  7. Observed Barium Emission Rates

    Science.gov (United States)

    Stenbaek-Nielsen, H. C.; Wescott, E. M.; Hallinan, T. J.

    1993-01-01

    The barium releases from the CRRES satellite have provided an opportunity for verifying theoretically calculated barium ion and neutral emission rates. Spectra of the five Caribbean releases in the summer of 1991 were taken with a spectrograph on board a U.S. Air Force jet aircraft. Because the line of sight release densities are not known, only relative rates could be obtained. The observed relative rates agree well with the theoretically calculated rates and, together with other observations, confirm the earlier detailed theoretical emission rates. The calculated emission rates can thus with good accuracy be used with photometric observations. It has been postulated that charge exchange between neutral barium and oxygen ions represents a significant source for ionization. If so. it should be associated with emissions at 4957.15 A and 5013.00 A, but these emissions were not detected.

  8. Comparison between two positive and one negative oral contrast medium for abdominal CT diagnosis

    International Nuclear Information System (INIS)

    Zwaan, M.; Gmelin, E.

    1989-01-01

    In a prospective randomised study three groups of 30 patients each were subjected to CT of the entire abdomen. The oral intestinal contrast media used were iodine solution (2%), barium suspension (1.5%) and paraffin emulsion (25%). The results were evaluated according to imaging, artifacts, assessability of the intestinal wall, taste and side effects. All three contrast media are suitable for marking the gastrointestinal tract; paraffin shows advantages in the upper part of the tract and is the only medium that enables assessment of the wall, while causing the lowest rate of artifacts. Barium has a high acceptance and the best tolerance of all contrast agents. (orig.) [de

  9. Atomization mechanisms for barium in furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Styris, D.L.

    1984-01-01

    Atomic absorption spectrometry and mass spectrometry are used simultaneously in order to elucidate atomization mechanisms of barium dichloride in pyrolytic graphite, vitreous carbon, and tantalum furnaces. Gas-phase barium dicarbide is observed to appear concurrently with the free barium. Barium oxide and barium dihydroxide precursors appear with the chlorides. Surface reactions involving species that are absorbed on the various furnaces are postulated to explain the appearances of the species that are observed in the gas phase. 49 references, 4 figures, 1 table

  10. Pre-procedural scout radiographs are unnecessary for routine pediatric fluoroscopic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Creeden, Sean G.; Rao, Anil G.; Eklund, Meryle J.; Hill, Jeanne G.; Thacker, Paul G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2017-03-15

    Although practice patterns vary, scout radiographs are often routinely performed with pediatric fluoroscopic studies. However few studies have evaluated their utility in routine pediatric fluoroscopy. To evaluate the value of scout abdomen radiographs in routine barium or water-soluble enema, upper gastrointestinal (GI) series, and voiding cystourethrogram pediatric fluoroscopic procedures. We retrospectively evaluated 723 barium or water-soluble enema, upper GI series, and voiding cystourethrogram fluoroscopic procedures performed at our institution. We assessed patient history and demographics, clinical indication for the examination, prior imaging findings and impressions, scout radiograph findings, additional findings provided by the scout radiograph that were previously unknown, and whether the scout radiograph contributed any findings that significantly changed management. We retrospectively evaluated 723 fluoroscopic studies (368 males and 355 females) in pediatric patients. Of these, 700 (96.8%) had a preliminary scout radiograph. Twenty-three (3.2%) had a same-day radiograph substituted as a scout radiograph. Preliminary scout abdomen radiographs/same-day radiographs showed no new significant findings in 719 (99.4%) studies. New but clinically insignificant findings were seen in 4 (0.6%) studies and included umbilical hernia, inguinal hernia and hip dysplasia. No findings were found on the scout radiographs that would either alter the examination performed or change management with regard to the exam. Pre-procedural scout abdomen radiographs are unnecessary in routine barium and water-soluble enema, upper GI series, and voiding cystourethrogram pediatric fluoroscopic procedures and can be substituted with a spot fluoroscopic last-image hold. (orig.)

  11. Nanoparticles of barium induce apoptosis in human phagocytes.

    Science.gov (United States)

    Mores, Luana; França, Eduardo Luzia; Silva, Núbia Andrade; Suchara, Eliane Aparecida; Honorio-França, Adenilda Cristina

    2015-01-01

    Nutrients and immunological factors of breast milk are essential for newborn growth and the development of their immune system, but this secretion can contain organic and inorganic toxins such as barium. Colostrum contamination with barium is an important issue to investigate because this naturally occurring element is also associated with human activity and industrial pollution. The study evaluated the administration of barium nanoparticles to colostrum, assessing the viability and functional activity of colostral mononuclear phagocytes. Colostrum was collected from 24 clinically healthy women (aged 18-35 years). Cell viability, superoxide release, intracellular Ca(2+) release, and phagocyte apoptosis were analyzed in the samples. Treatment with barium lowered mononuclear phagocyte viability, increased superoxide release, and reduced intracellular calcium release. In addition, barium increased cell death by apoptosis. These data suggest that nanoparticles of barium in colostrum are toxic to cells, showing the importance of avoiding exposure to this element.

  12. Micro-computed tomography of fatigue microdamage in cortical bone using a barium sulfate contrast agent.

    Science.gov (United States)

    Leng, Huijie; Wang, Xiang; Ross, Ryan D; Niebur, Glen L; Roeder, Ryan K

    2008-01-01

    Accumulation of microdamage during fatigue can lead to increased fracture susceptibility in bone. Current techniques for imaging microdamage in bone are inherently destructive and two-dimensional. Therefore, the objective of this study was to image the accumulation of fatigue microdamage in cortical bone using micro-computed tomography (micro-CT) with a barium sulfate (BaSO(4)) contrast agent. Two symmetric notches were machined on the tensile surface of bovine cortical bone beams in order to generate damage ahead of the stress concentrations during four-point bending fatigue. Specimens were loaded to a specified number of cycles or until one notch fractured, such that the other notch exhibited the accumulation of microdamage prior to fracture. Microdamage ahead of the notch was stained in vitro by precipitation of BaSO(4) and imaged using micro-CT. Reconstructed images showed a distinct region of bright voxels around the notch tip or along propagating cracks due to the presence of BaSO(4), which was verified by backscattered electron imaging and energy dispersive spectroscopy. The shape of the stained region ahead of the notch tip was consistent with principal strain contours calculated by finite element analysis. The relative volume of the stained region was correlated with the number of loading cycles by non-linear regression using a power-law. This study demonstrates new methods for the non-destructive and three-dimensional detection of fatigue microdamage accumulation in cortical bone in vitro, which may be useful to gain further understanding into the role of microdamage in bone fragility.

  13. Internal hemorrhoids - their typical radiological appearance and differential diagnosis to carcinoma of rectum and anus

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, V.; Koester, R.

    1984-11-01

    The main indication for colon barium enema examination is occult bleeding or bleeding noticed by the patient himself. The radiologist has to take into account all clinical details that could lead to bleeding and to document them. The most frequent causes of rectal bleeding are hemorrhoids and diverticulosis/itis which in marked cases may have a tumor-like appearance. A good double-contrast examination of the colon must not only exclude tumors, polyps or inflammatary diseases but also demonstrate other causes of bleeding. The presented paper describes typical roentgen signs and gives criteria to differentiate hemorrhoids from deeply situated cancer of the rectum or anus.

  14. Internal hemorrhoids - their typical radiological appearance and differential diagnosis to carcinoma of rectum and anus

    International Nuclear Information System (INIS)

    Fiedler, V.; Koester, R.

    1984-01-01

    The main indication for colon barium enema examination is occult bleeding or bleeding noticed by the patient himself. The radiologist has to take into account all clinical details that could lead to bleeding and to document them. The most frequent causes of rectal bleeding are hemorrhoids and diverticulosis/itis which in marked cases may have a tumor-like appearence. A good double-contrast examination of the colon must not only exclude tumors, polyps or inflammotary diseases but also demonstrate other causes of bleeding. The presented paper describes typical roentgen signs and gives criteria to differentiate hemorrhoids from deeply situated cancer of the rectum or anus. (orig.) [de

  15. CT colonography combined with fistulography - a case of periannal fistula of a 6 months old child

    International Nuclear Information System (INIS)

    Sirakov, N.; Velkova, K.; Sirakov, V.; Tashev, P.

    2007-01-01

    We present a 6 months old child with perianal fistula with repeated secretion from it. The child was examined by double contrast barium enema and transrectal ultrasonography that gave suggestions of perianal fistula with no communication to the rectum and suspicion of a anal duplication of the rectum. The child was examined by CT colonography combined with fistulography. The exam was carried out on a axial CT Somatom Emotion by Siemens. The purpose of our report is to present the results of the combination of CT colonography and fistulography, applied to a 6-month-old child, as well as to present the specific protocol that we used for this examination. (authors)

  16. Barium appendicitis after upper gastrointestinal imaging.

    Science.gov (United States)

    Novotny, Nathan M; Lillemoe, Keith D; Falimirski, Mark E

    2010-02-01

    Barium appendicitis (BA) is a rarely seen entity with fewer than 30 reports in the literature. However, it is a known complication of barium imaging. To report a case of BA in a patient whose computed tomography (CT) scan was initially read as foreign body ingestion. An 18-year-old man presented with right lower quadrant pain after upper gastrointestinal imaging 2 weeks prior. A CT scan was obtained of his abdomen and pelvis that revealed a finding that was interpreted as a foreign body at the area of the terminal ileum. A plain X-ray study of the abdomen revealed radiopaque appendicoliths. Pathology confirmed the diagnosis of barium appendicitis. BA is a rare entity and the pathogenesis is unclear. Shorter intervals between barium study and presentation with appendicitis usually correlate with fewer complications. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  17. Comparison of contrast media for visualization of the colon of healthy dogs during computed tomography and ultrasonography.

    Science.gov (United States)

    Cheon, Byunggyu; Moon, Sohyeon; Park, Seungjo; Lee, Sang-Kwon; Hong, Sunghwa; Cho, Hyun; Choi, Jihye

    2016-11-01

    OBJECTIVE To evaluate contrast agents for their ability to improve visualization of the colon wall and lumen during CT and ultrasonography. ANIMALS 10 healthy adult Beagles. PROCEDURES Food was withheld from dogs for 36 hours, after which dogs consumed 250 mL of polyethylene glycol solution. Dogs were then anesthetized, a contrast agent (tap water, diluted barium, or air; order randomly assigned) was administered rectally, iodine contrast medium (880 mg of I/kg) was administered IV, and CT and ultrasonography of the colon were performed. After a 1-week washout period, this process was repeated with a different contrast agent until all agents had been evaluated. Two investigators reviewed the CT and ultrasonographic images for colon wall thickness, conspicuity, artifacts, wall layering, and degree of lumen dilation at 4 sites. RESULTS Thickness of the colon wall was greatest in CT and ultrasonographic images with water used as contrast agent, followed by barium and then air. The CT images obtained after water administration had a smooth appearance that outlined the colonic mucosa and had the highest score of the 3 contrast agents for wall conspicuity. Although no substantial artifacts related to any of the contrast agents were identified on CT images, barium- and gas-induced shadowing and reverberation artifacts hindered wall evaluation during ultrasonography. For ultrasonography, the degree of conspicuity was highest with barium in the near-field wall and with water in the far-field wall. In contrast to CT, ultrasonography could be used to distinguish wall layering, and the mucosal and muscular layers were distinct with all contrast agents. CONCLUSIONS AND CLINICAL RELEVANCE Use of water as a contrast agent for both CT and ultrasonography of the colon in dogs compensated for each imaging modality's disadvantages and could be beneficial in the diagnosis of colon disease.

  18. Kinematic and spatial distributions of barium stars - are the barium stars and Am stars related?

    International Nuclear Information System (INIS)

    Hakkila, J.

    1989-01-01

    The possibility of an evolutionary link between Am stars and barium stars is considered, and an examination of previous data suggests that barium star precursors are main-sequence stars of intermediate mass, are most likely A and/or F dwarfs, and are intermediate-mass binaries with close to intermediate orbital separations. The possible role of mass transfer in the later development of Am systems is explored. Mass transfer and loss from systems with a range of masses and orbital separations may explain such statistical peculiarities of barium stars as the large dispersion in absolute magnitude, the large range of elemental abundances from star to star, and the small number of stars with large peculiar velocities. 93 refs

  19. In-line X-ray phase-contrast imaging of murine liver microvasculature ex vivo

    International Nuclear Information System (INIS)

    Li Beilei; Xu Min; Shi Hongcheng; Chen Shaoliang; Wu Weizhong; Peng Guanyun; Zhang Xi; Peng Yifeng

    2012-01-01

    Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors. Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method. Visualizing murine liver microvasculature ex vivo with phase-contrast X-ray imaging was performed at Shanghai Synchrotron Radiation Facility. Barium sulfate and physiological saline were used as contrast agents for the blood vessels. Blood vessels of <Φ20 μm could be detected by replacing resident blood with physiological saline or barium sulfate. An entire branch of the portal vein (from the main axial portal vein to the ninth generation of branching) could be captured in a single phase-contrast image. It is demonstrated that selective angiography based on phase contrast X-ray imaging, with a physiological material of low Z elements (such as saline) being the contrast agent, is a viable imaging strategy. Further efforts will be focused on using the technique to image tumor angiogenesis. (authors)

  20. Efficacy and Safety of Combined Oral and Enema Therapy Using Polyethylene Glycol 3350-Electrolyte for Disimpaction in Pediatric Constipation

    OpenAIRE

    Yoo, Taeyeon; Bae, Sun Hwan

    2017-01-01

    Purpose We evaluated the efficacy and safety of combined oral and enema therapy using polyethylene glycol (PEG) 3350 with electrolyte solution for disimpaction in hospitalized children. Methods We retrospectively studied 28 children having functional constipation who received inpatient treatment between 2008 and 2016. The amount of oral PEG 3350 electrolyte solution administered was 50–70 mL/kg/d (PEG 3350, 3–4.1 g/kg/d), and an enema solution was administered 1–2 times a day as a single dose...

  1. Biofilm imaging in porous media by laboratory X-Ray tomography: Combining a non-destructive contrast agent with propagation-based phase-contrast imaging tools.

    Science.gov (United States)

    Carrel, Maxence; Beltran, Mario A; Morales, Verónica L; Derlon, Nicolas; Morgenroth, Eberhard; Kaufmann, Rolf; Holzner, Markus

    2017-01-01

    X-ray tomography is a powerful tool giving access to the morphology of biofilms, in 3D porous media, at the mesoscale. Due to the high water content of biofilms, the attenuation coefficient of biofilms and water are very close, hindering the distinction between biofilms and water without the use of contrast agents. Until now, the use of contrast agents such as barium sulfate, silver-coated micro-particles or 1-chloronaphtalene added to the liquid phase allowed imaging the biofilm 3D morphology. However, these contrast agents are not passive and potentially interact with the biofilm when injected into the sample. Here, we use a natural inorganic compound, namely iron sulfate, as a contrast agent progressively bounded in dilute or colloidal form into the EPS matrix during biofilm growth. By combining a very long source-to-detector distance on a X-ray laboratory source with a Lorentzian filter implemented prior to tomographic reconstruction, we substantially increase the contrast between the biofilm and the surrounding liquid, which allows revealing the 3D biofilm morphology. A comparison of this new method with the method proposed by Davit et al (Davit et al., 2011), which uses barium sulfate as a contrast agent to mark the liquid phase was performed. Quantitative evaluations between the methods revealed substantial differences for the volumetric fractions obtained from both methods. Namely, contrast agent-biofilm interactions (e.g. biofilm detachment) occurring during barium sulfate injection caused a reduction of the biofilm volumetric fraction of more than 50% and displacement of biofilm patches elsewhere in the column. Two key advantages of the newly proposed method are that passive addition of iron sulfate maintains the integrity of the biofilm prior to imaging, and that the biofilm itself is marked by the contrast agent, rather than the liquid phase as in other available methods. The iron sulfate method presented can be applied to understand biofilm development

  2. Radiological imaging of rectal cancer

    Directory of Open Access Journals (Sweden)

    Lidija Lincender-Cvijetić

    2012-11-01

    Full Text Available This article discusses the possibilities of diagnosing abdominal imaging in patients with rectal cancer, detecting lesions and assessing the stage of the lesions, in order to select the appropriate therapy. Before the introduction of imaging technologies, the diagnosis of colorectal pathology was based on conventional methods of inspecting intestines with a barium enema, with either a single or double contrast barium enema. Following the development of endoscopic methods and the wide use of colonoscopy, colonoscopy became the method of choice for diagnosing colorectal diseases. The improvement of Computerized Tomography (CT and Magnetic Resonance Imaging (MRI, gave us new possibilities for diagnosing colorectal cancer. For rectal cancer, trans-rectal US (TRUS or endo-anal US (EAUS have a significant role. For staging rectal cancer, the Multi Slice Computed Tomography (MSCT is not the method of choice, but Magnetic Resonance Imaging (MRI is preferred when it comes to monitoring the rectum. Therole of the MRI in the T staging of rectal cancer is crucial in preoperative assessment of: thickness – the width of the tumor, the extramural invasion, the circumference of resection margin (CRM, andthe assessment of the inclusion of mesorectal fascia. For successful execution of surgical techniques, good diagnostic imaging of the cancer is necessary in order to have a low level of recurrence. According to medical studies, the sensitivity of FDG-PET in diagnosing metastatic nodals is low, but for now it is not recommended in routine diagnosis of metastatic colorectal carcinoma.

  3. Audit of the introduction of CT colonography for detection of colorectal carcinoma in a non-academic environment and its implications for the national bowel cancer screening programme

    International Nuclear Information System (INIS)

    Thomas, S.; Atchley, J.; Higginson, A.

    2009-01-01

    Aim: To compare the sensitivity of double-contrast barium enema (DCBE) with computed tomography colonography (CTC) to determine whether CTC is superior for the detection of colorectal cancer (CRC) locally, and to compare the results to those of a national barium enema audit. Materials and methods: All patients undergoing diagnostic DCBE or CTC between January 2003 and December 2005 were identified from the picture archiving communication system (PACS). Patients with a confirmed diagnosis of CRC were identified from the local cancer registry. Patients who were not diagnosed as having CRC on imaging were assumed true negatives if they were not listed in the cancer registry by December 2007, giving a minimum of 2 years follow-up. DCBE and CTC reports of all patients with CRC were analysed, and cancer detection was considered to have occurred (positive test result) if the report stated the definite presence of CRC or possible CRC requiring further investigation. Results: 2520 DCBEs and 604 CTCs were included. Twenty-one of 33 patients with CRC were detected using DCBE (incidence 1.31%, sensitivity 63.7%). Thirty-two of 33 patients with CRC were -detected using CTC (incidence 5.46%, sensitivity 97.7%). Conclusion: CTC is more sensitive for the detection of CRC, and its introduction in a district general hospital is justified. However, there has been a consequent decline in DCBE sensitivity, which, if reflected nationally, suggests CTC is the preferential screening test for CRC

  4. Audit of the introduction of CT colonography for detection of colorectal carcinoma in a non-academic environment and its implications for the national bowel cancer screening programme

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, S. [Department of Radiology, Queen Alexandra Hospital, Southwick Hill Road, Cosham, Portsmouth PO3 6AD (United Kingdom)], E-mail: Susan.Thomas@porthosp.nhs.uk; Atchley, J.; Higginson, A. [Department of Radiology, Queen Alexandra Hospital, Southwick Hill Road, Cosham, Portsmouth PO3 6AD (United Kingdom)

    2009-02-15

    Aim: To compare the sensitivity of double-contrast barium enema (DCBE) with computed tomography colonography (CTC) to determine whether CTC is superior for the detection of colorectal cancer (CRC) locally, and to compare the results to those of a national barium enema audit. Materials and methods: All patients undergoing diagnostic DCBE or CTC between January 2003 and December 2005 were identified from the picture archiving communication system (PACS). Patients with a confirmed diagnosis of CRC were identified from the local cancer registry. Patients who were not diagnosed as having CRC on imaging were assumed true negatives if they were not listed in the cancer registry by December 2007, giving a minimum of 2 years follow-up. DCBE and CTC reports of all patients with CRC were analysed, and cancer detection was considered to have occurred (positive test result) if the report stated the definite presence of CRC or possible CRC requiring further investigation. Results: 2520 DCBEs and 604 CTCs were included. Twenty-one of 33 patients with CRC were detected using DCBE (incidence 1.31%, sensitivity 63.7%). Thirty-two of 33 patients with CRC were -detected using CTC (incidence 5.46%, sensitivity 97.7%). Conclusion: CTC is more sensitive for the detection of CRC, and its introduction in a district general hospital is justified. However, there has been a consequent decline in DCBE sensitivity, which, if reflected nationally, suggests CTC is the preferential screening test for CRC.

  5. Laser cooling and trapping of barium

    NARCIS (Netherlands)

    De, Subhadeep

    2008-01-01

    Laser cooling and trapping of heavy alkaline-earth element barium have been demonstrated for the first time ever. For any possible cycling transition in barium that could provide strong cooling forces, the excited state has a very large branching probability to metastable states. Additional lasers

  6. Contrast media for radiological examination in gastrointestinal tract leakage

    International Nuclear Information System (INIS)

    Ginai-Karamat, A.Z.

    1987-01-01

    The aim of this investigation has been to find a safe and suitable contrast medium (CM) for radiological evaluation of the gastrointestinal tract (GIT) in cases where leakage outside the GIT can be suspected. An experimental study was carried out to evaluate the reactions of various available CM in the bronchi and lungs, mediastinum, pleura and peritoneum of rats. The CM evaluated in the experimental study were, pure barium sulphate (without any additives), commercial barium sulphate (Micropaque, with additives), Dionosil, Hytrast, Gastrografin, Amipaque (in pleura Omnipaque) and Hexabrix. (Auth.)

  7. Bioadhesive agents in addition to oral contrast media - evaluation in an animal model

    International Nuclear Information System (INIS)

    Conrad, R.; Schneider, G.; Textor, J.; Schild, H.H.; Fimmers, R.

    1998-01-01

    Purpose: To evaluate the additional effect of bioadhesives in combination with iotrolan and barium as oral contrast media in an animal model. Method: The bioadhesives Noveon, CMC, Tylose and Carbopol 934 were added to iotrolan and barium. The solutions were administered to rabbits by a feeding tube. The animals were investigated by computed tomography (CT) and radiography after 0,5, 4, 12, 24 and in part after 48 hours. Mucosal coating and contrast filling of the bowel were evaluated. Results: Addition of bioadhesives to oral contrast media effected long-term contrast in the small intestine and colon, but no improvement in continuous filling and coating of the gastrointestinal tract was detected. Mucosal coating was seen only in short regions of the caecum and small intestine. In CT the best results for coating were observed with tylose and CMC, in radiography additionally with carbopol and noveon. All contrast medium solutions were well tolerated. Conclusion: The evaluated contrast medium solutions with bioadhesives have shown long-term contrast but no improvement in coating in comparison to conventional oral contrast media. (orig.) [de

  8. Large bowel leiomyosarcoma - a case report

    International Nuclear Information System (INIS)

    Lopes, Simone Goncalves; Marchiori, Edson; Brick, Julieta Figueiredo; Curty Neto, Eduardo; Scherman, Alexandre; Silva, Ana Carina Gamboa da; Machado, Bruno Beber

    2001-01-01

    The authors report a case of a 49-year-old male patient with leiomyosarcoma of the ascending colon. The patient presented with anemia and an abdominal mass, and the symptoms progressed until a final diagnosis was made nine months later. A plain abdominal x-ray showed the presence of gas outside the bowel, in the right hypochondrium. The double contrast barium enema showed a sublevel displacement of the hepatic flexure and diverticula. An abdominal ultrasound revealed a heterogeneous expansive lesion below the liver containing gas, and a computed tomography of the abdomen revealed an excavated mass below the liver containing liquid, that was not filled by contrast medium. The patient was submitted to a right hemicolectomy with ileocoloanastomosis and the histopathological analysis of the excised material revealed a leiomyosarcoma of the ascending colon. (author)

  9. Barium determination in gastric contents, blood and urine by inductively coupled plasma mass spectrometry in the case of oral barium chloride poisoning.

    Science.gov (United States)

    Łukasik-Głębocka, Magdalena; Sommerfeld, Karina; Hanć, Anetta; Grzegorowski, Adam; Barałkiewicz, Danuta; Gaca, Michał; Zielińska-Psuja, Barbara

    2014-01-01

    A serious case of barium intoxication from suicidal ingestion is reported. Oral barium chloride poisoning with hypokalemia, neuromuscular and cardiac toxicity, treated with intravenous potassium supplementation and hemodialysis, was confirmed by the determination of barium concentrations in gastric contents, blood, serum and urine using the inductively coupled plasma mass spectrometry method. Barium concentrations in the analyzed specimens were 20.45 µg/L in serum, 150 µg/L in blood, 10,500 µg/L in urine and 63,500 µg/L in gastric contents. Results were compared with barium levels obtained from a non-intoxicated person. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Coprecipitation of iron and silver with barium fluoride

    International Nuclear Information System (INIS)

    Kopilova, N.V.; Khamidov, B.O.; Kashina, Z.A.; Ikrami, D.D.

    1986-01-01

    Distribution of trace contaminants of iron and silver at coprecipitation of barium fluoride is studied in present work. It is defined that iron almost completely coprecipitated with barium fluoride in wide range of ph 5.5-12. Silver coprecipitated with barium fluoride in ph range 4-7. The value of coprecipitation varies from 94% to 100%.

  11. Minimal preparation CT for the diagnosis of suspected colorectal cancer in the frail and elderly patient

    International Nuclear Information System (INIS)

    Koo, B.C.; Ng, C.S.; U-King-Im, J.; Prevost, A.T.; Freeman, A.H.

    2006-01-01

    Colorectal cancer is a common malignancy with an increased incidence in the elderly population. Traditional methods of evaluating this disease have included double contrast barium enema and colonoscopy. Unfortunately, in the frail and elderly patient, these investigations can be difficult to perform and are often not tolerated. Minimal preparation computed tomography (MPCT) of the colon has been suggested as an alternative in this patient population. In this technique, no bowel preparation is used apart from the administration of oral contrast medium. The patient is imaged only in the supine position, without per rectal insufflation of gas or barium. This article reviews the experience to date of MPCT in detecting colonic tumours, and compares its efficacy to the traditional methods. A meta-analysis of the studies allowed estimation of the pooled sensitivity of MPCT to be 83% (95% confidence interval: 76-89%), and pooled specificity to be 90% (95% CI: 85-94%). An added advantage of MPCT is the ability to identify extra-colonic pathology, and this aspect is also reviewed. In addition, the common radiological features and pitfalls in identifying colonic tumours by MPCT are discussed

  12. Minimal preparation CT for the diagnosis of suspected colorectal cancer in the frail and elderly patient

    Energy Technology Data Exchange (ETDEWEB)

    Koo, B.C. [Department of Radiology, Addenbrooke' s NHS Trust, Cambridge (United Kingdom)]. E-mail: bkoo@doctors.org.uk; Ng, C.S. [Division of Diagnostic Imaging, Department of Radiology, The University of Texas, M.D. Anderson Cancer Center, Houston, TX (United States); U-King-Im, J. [Department of Radiology, Addenbrooke' s NHS Trust, Cambridge (United Kingdom); Prevost, A.T. [Department of Public Health and Primary Care, Centre of Applied Medical Statistics, Univeristy of Cambridge, Institute of Public Health, Cambridge (United Kingdom); Freeman, A.H. [Department of Radiology, Addenbrooke' s NHS Trust, Cambridge (United Kingdom)

    2006-02-15

    Colorectal cancer is a common malignancy with an increased incidence in the elderly population. Traditional methods of evaluating this disease have included double contrast barium enema and colonoscopy. Unfortunately, in the frail and elderly patient, these investigations can be difficult to perform and are often not tolerated. Minimal preparation computed tomography (MPCT) of the colon has been suggested as an alternative in this patient population. In this technique, no bowel preparation is used apart from the administration of oral contrast medium. The patient is imaged only in the supine position, without per rectal insufflation of gas or barium. This article reviews the experience to date of MPCT in detecting colonic tumours, and compares its efficacy to the traditional methods. A meta-analysis of the studies allowed estimation of the pooled sensitivity of MPCT to be 83% (95% confidence interval: 76-89%), and pooled specificity to be 90% (95% CI: 85-94%). An added advantage of MPCT is the ability to identify extra-colonic pathology, and this aspect is also reviewed. In addition, the common radiological features and pitfalls in identifying colonic tumours by MPCT are discussed.

  13. Synthesis, photoluminescence and magnetic properties of barium vanadate nanoflowers

    International Nuclear Information System (INIS)

    Xu, Jing; Hu, Chenguo; Xi, Yi; Peng, Chen; Wan, Buyong; He, Xiaoshan

    2011-01-01

    Graphical abstract: The flower-shaped barium vanadate was obtained for the first time. The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. Research highlights: → In the paper, the flower-shaped barium vanadate were obtained for the first time. The CHM method used here is new and simple for preparation of barium vanadate. → The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. The strong bluish-green emission was observed. → The ferromagnetic behavior of the barium vanadate nanoflowers was found with saturation magnetization of about 83.50 x 10 -3 emu/g, coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10 -3 emu/g. → The mechanisms of PL and magnetic property of barium vanadate nanoflowers have been discussed. -- Abstract: The flower-shaped barium vanadate has been obtained by the composite hydroxide mediated (CHM) method from V 2 O 5 and BaCl 2 at 200 o C for 13 h. XRD and XPS spectrum of the as-synthesized sample indicate it is hexagonal Ba 3 V 2 O 8 with small amount of Ba 3 VO 4.8 coexistence. Scan electron microscope and transmission electron microscope display that the flower-shaped crystals are composed of nanosheets with thickness of ∼20 nm. The UV-visible spectrum shows that the barium vanadate sample has two optical gaps (3.85 eV and 3.12 eV). Photoluminescence spectrum of the barium vanadate flowers exhibits a visible light emission centered at 492 and 525 nm which might be attributed to VO 4 tetrahedron with T d symmetry in Ba 3 V 2 O 8 . The ferromagnetic behavior of the barium vanadate nanoflowers has been found with saturation magnetization of about 83.50 x 10 -3 emu/g, coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10 -3 emu/g, which is mainly due to the presence of a non-orthovanadate phase with spin S = 1/2.

  14. Limited utility of preoperative studies in preparation for colostomy closure.

    Science.gov (United States)

    Pokorny, R M; Heniford, T; Allen, J W; Tuckson, W B; Galandiuk, S

    1999-04-01

    Numerous diagnostic and therapeutic practices are used in an attempt to reduce the morbidity of colostomy closures. Our principal aim was to evaluate the role of preoperative studies, specifically barium enemas and endoscopic examinations, performed before colostomy closures. Additionally, we wished to identify other practices involved in the perioperative management of patients undergoing colostomy closure that influenced morbidity. The records of 100 consecutive patients who underwent elective colostomy closure at University of Louisville Hospital between January 1989 and July 1995 were reviewed. Wound infection was the most common complication (12%). Various bowel preparations were equivalent in efficacy and did not influence the complication rate. Intermittent wound irrigation with antibiotics for 3 days postoperatively, via subcutaneous drains, was associated with a low incidence of incision infection. Preoperative barium enema or sigmoidoscopy were often performed but rarely useful. Performing these examinations merely increased hospital cost without a corresponding decline in morbidity.

  15. The radiographic examination of the colon

    International Nuclear Information System (INIS)

    Hendrix, T.R.; Saba, G.P. II.

    1980-01-01

    To provide medical and scientific background on certain selected technologies generally considered to be of particular significance, the National Center for Health Care Technology commissioned a series of overview papers, one of which is entitled 'The Radiographic Examination of the Colon.' These overviews are likely to be of most immediate interest to clinicians and biomedical scientists; they also may provide valuable background for assessments undertaken by the Center and for exploring the broad societal implications of health care technologies. Barium enema is the most available and widely used technique for examining the colon. It is often a routine part of the gastrointestinal work-up regardless of the suspected basis, anatomical or functional, of the patient's symptoms. Indeed, common practice is not to entertain a diagnosis of functional disorder before excluding all reasonable possibility of an anatomical abnormality. Barium enema is one of the most frequently ordered radiographic examinations

  16. 40 CFR 721.10011 - Barium calcium manganese strontium oxide.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Barium calcium manganese strontium... Specific Chemical Substances § 721.10011 Barium calcium manganese strontium oxide. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium calcium...

  17. History and challenges of barium titanate: Part I

    Directory of Open Access Journals (Sweden)

    Vijatović M.M.

    2008-01-01

    Full Text Available Barium titanate is the first ferroelectric ceramics and a good candidate for a variety of applications due to its excellent dielectric, ferroelectric and piezoelectric properties. Barium titanate is a member of a large family of compounds with the general formula ABO3 called perovskites. Barium titanate can be prepared using different methods. The synthesis method depends on the desired characteristics for the end application. The used method has a significant influence on the structure and properties of barium titanate materials. In this review paper, Part I contains a study of the BaTiO3 structure and frequently used synthesis methods.

  18. Microcapsules with intrinsic barium radiopacity for immunoprotection and X-ray/CT imaging of pancreatic islet cells.

    Science.gov (United States)

    Arifin, Dian R; Manek, Sameer; Call, Emma; Arepally, Aravind; Bulte, Jeff W M

    2012-06-01

    Microencapsulation is a commonly used technique for immunoprotection of engrafted therapeutic cells. We investigated a library of capsule formulations to determine the most optimal formulation for pancreatic beta islet cell transplantation, using barium as the gelating ion and clinical-grade protamine sulfate (PS) as a new cationic capsule cross-linker. Barium-gelated alginate/PS/alginate microcapsules (APSA, diameter = 444 ± 21 μm) proved to be mechanically stronger and supported a higher cell viability as compared to conventional alginate/poly-l-lysine/alginate (APLLA) capsules. Human pancreatic islets encapsulated inside APSA capsules, gelated with 20 mm barium as optimal concentration, exhibited a sustained morphological integrity, viability, and functionality for at least 3-4 weeks in vitro, with secreted human C-peptide levels of 0.2-160 pg/ml/islet. Unlike APLLA capsules that are gelled with calcium, barium-APSA capsules are intrinsically radiopaque and, when engrafted into mice, could be readily imaged in vivo with micro-computed tomography (CT). Without the need of adding contrast agents, these capsules offer a clinically applicable alternative for simultaneous immunoprotection and real-time, non-invasive X-ray/CT monitoring of engrafted cells during and after in vivo administration. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Double-contrast examination of the gastric antrum without Duodenal superposition

    International Nuclear Information System (INIS)

    Treugut, H.; Isper, J.

    1980-01-01

    By using a modified technique of double-contrast examination of the stomach it was possible in 75% to perform a study without superposition of the duodenum and jejunum on the distal stomach compared to 36% with the usual method. In this technique a small amount (50 ml) of Barium-suspension is given to the patient in left decubitus position by a straw or gastric tube after antiperistaltic medication. There was no difference in the quality of mucosa-coating compared to the technique using higher volumes of Barium. (orig.) [de

  20. Clinical Diagnosis of Achalasia: How Reliable is the Barium X-Ray?

    Directory of Open Access Journals (Sweden)

    I El-Takli

    2006-01-01

    Full Text Available Manometry is considered to be the gold standard for the diagnosis of achalasia. However, many physicians believe that contrast radiography, classically showing esophageal dilation with bird-beak narrowing of the gastroesophageal junction, is also accurate in either diagnosing or excluding the disorder. The aim of the current study was to determine the accuracy of barium x-ray in the diagnosis of achalasia. The radiological diagnosis of all patients manometrically diagnosed with achalasia (using conventional criteria between January 1994 and June 1998 were reviewed. A total of 51 cases of achalasia were identified. Thirteen patients were excluded because they either did not have contrast radiography before a manometric diagnosis or had their x-rays performed more than six months previously. Of the remaining 38 patients, achalasia was stated as a diagnostic possibility in the radiologists report in only 22 (58% of those patients. Achalasia was not considered in the remaining 16 patients: two were reported as normal, four as having stenosis/narrowing in distal esophagus, two as having presbyesophagus, one as having mild gastroesophageal reflux and seven as having nonspecific dysmotility. To determine the reason for the diagnostic failure of the barium x-ray, an expert gastrointestinal radiologist reviewed 12 of the nondiagnostic x-rays in a blinded fashion, interspersed with 10 randomly selected esophageal-contrast radiographs from control subjects to avoid bias. Of these initially nondiagnostic x-rays in achalasia patients, typical radiological features of achalasia were deemed to be present in 50%. The present study indicates that contrast radiography lacks sensitivity in the diagnosis of achalasia. This is not only due to radiologist oversight but also because of the absence of the characteristic radiological features in many cases. This reinforces the important role of esophageal manometry in patients with persistent nonstructural dysphagia.

  1. Comparative study of pneumocystography, positive contrast cystography and double contrast cystography in dogs; Estudio comparativo entre la neumocistografia, la cistografia de contraste positivo y la cistografia de doble contraste en perros

    Energy Technology Data Exchange (ETDEWEB)

    Thibaut, J.; Parada, E. [Universidad Austral de Chile, Valdivia (Chile); Vargas, L.; Deppe, R.; Born, R.

    1997-07-01

    In order to compare three radiographic techniques: pneumocystography, positive contrast cystography and double contrast cystography, three series of 24 radiographs each in lateral and ventrodorsal projections were made. Six healthy adult male dogs with weight ranging between 7 and 16 kg were used. Food was withheld for 24 hours and two enemas were made before the series of radiographs were taken. Dogs were anaesthetized with sodium thiopental (20 mg/kg i.v.). The contrast medium was introduced through a urethral catheter. Pneumocystography was performed in the first series introducing air (10 ml/kg) in the bladder. Positive contrast cystography was performed in the second series introducing Hypaque M-60% diluted, contributing 100 mg of iodine per ml (10 ml/kg). In the double contrast cystography Hypaque M-60% diluted (10 ml) was introduced, in concentration of 150 mg of iodine per ml. Then air was introduced (10 ml/kg) through a catheter. Plates were taken in both projections at 1 and 10 minutes for each technique. The radiographic plates of each series were analized comparing the characteristics of radiographic density, outline and size. In neumocystography, positive contrast and double contrast cystography, the radiographic density was predominantly low, high and intermediate, respectively. The radiographic outline was mainly regular for the three techniques. With respect to bladder size, there was a decrease of height and an increase of length and width at 10 minutes. Comparing these three radiographic techniques, it can be concluded that the one that best outlines the bladder mucosa is double contrast. Pneumocystography provides the best image for opaque structures and cystography best shows the position of the urinary bladder [Spanish] Se tomaron 3 series de 24 radiografias cada una, en proyeccion lateral y ventrodorsal. Se trabajo en cada serie con 6 perros machos clinicamente sanos 5 con un peso que vario entre los 7 y 16 kg. Previo a cada serie se efectuo

  2. Barium transport in the hot spot region of fluorescent lamps

    International Nuclear Information System (INIS)

    Sigeneger, F; Rackow, K; Uhrlandt, D; Ehlbeck, J; Lieder, G

    2010-01-01

    The transport of barium atoms and ions in the vicinity of the hot spot in fluorescent lamps operating at 25 kHz is investigated by a combined experimental and theoretical approach. By laser-induced fluorescence, the particle densities of barium atoms and ions were measured time-resolved at different distances from the spot centre. In addition, the time-dependent cathode fall voltage was measured using an improved band method. The model combines a kinetic part for the electrons with a fluid part for the barium atoms and ions. Both parts are spatially resolved in spherically symmetric geometry. The space-dependent electron Boltzmann equation yields the electron density and the ionization rate coefficient of barium as functions of the cathode fall voltage. These results are used to solve the time-dependent particle balance equations of barium atoms and ions which include the ionization of barium as gain and loss terms, respectively. Good agreement between the measured and calculated particle densities of barium atoms is obtained. A sensitive dependence of the ionization frequency and of the barium particle densities on the cathode fall voltage was found.

  3. Creating unstable velocity-space distributions with barium injections

    International Nuclear Information System (INIS)

    Pongratz, M.B.

    1983-01-01

    Large Debye lengths relative to detector dimensions and the absence of confining walls makes space an attractive laboratory for studying fundamental theories of plasma instabilities. However, natural space plasmas are rarely found displaced from equilibrium enough to permit isolation and diagnosis of the controlling parameters and driving conditions. Furthermore, any plasma or field response to the departure from equilibrium can be masked by noise in the natural system. Active experiments provide a technique for addressing the chicken or egg dilemma. Early thermite barium releases were generally conducted at low altitudes from sounding rockets to trace electric fields passively or to study configuration-space instabilities. One can also study velocity-space instabilities with barium releases. Neutral barium vapor releases wherein a typical speed greatly exceeds the thermal speed can be used to produce barium ion velocity-space distributions that should be subject to a number of microinstabilities. We examine the ion velocity-space distributions resulting from barium injections from orbiting spacecraft and shaped-charges

  4. An Investigation into the Relationship between Cigarette Smoking and Diverticular Disease of the Colon

    OpenAIRE

    Christopher G Jamieson; Michael J Weinberg; Joanne Lorraine

    1990-01-01

    A retrospective study was conducted to determine the relationship between cigarette smoking and diverticular disease of the colon. One hundred and two patients undergoing barium enema were assessed for diverticular disease and smoking history. No significant positive association between smoking and diverticular disease was found.

  5. PAINFUL IRRITABLE-BOWEL-SYNDROME AND SIGMOID CONTRACTIONS

    NARCIS (Netherlands)

    RITSEMA, GH; THIJN, CJP

    Fifteen patients with abdominal pain compatible with the irritable bowel syndrome (IBS) were examined by barium enema and pressure recording. Strong circular contractions of the sigmoid colon and pressure recordings correlated with the characteristic pain in 13 of the 15 patients. In 15 control

  6. Evaluation of gastrointestinal tract transit times using barium-impregnated polyethylene spheres and barium sulfate suspension in a domestic pigeon (Columba livia) model.

    Science.gov (United States)

    Bloch, Rebecca A; Cronin, Kimberly; Hoover, John P; Pechman, Robert D; Payton, Mark E

    2010-03-01

    Barium impregnated polyethylene spheres (BIPS) are used in small animal medicine as an alternative to barium sulfate for radiographic studies of the gastrointestinal tract. To determine the usefulness of BIPS as an alternative to barium suspension in measuring gastrointestinal (GI) transit time for avian species, ventrodorsal radiographs were used to follow the passage of BIPS and 30% barium sulfate suspension through the GI tracts of domestic pigeons (Columba livia). Gastrointestinal transit times of thirty 1.5-mm BIPS administered in moistened gelatin capsules and 30% barium sulfate suspension gavaged into the crop were compared in 6 pigeons. Although the barium suspension passed out of the GI tract of all pigeons within 24 hours, the 1.5-mm BIPS remained in the ventriculus for 368.0 +/- 176.8 hours and did not clear the GI tract for 424.0 +/- 204.6 hours. Although the times for passage of BIPS and 30% barium sulfate suspension from the crop into the ventriculus were not significantly different (P = .14), the times for passage of BIPS from the ventriculus into the large intestine-cloaca and for clearance from the GI tract of the pigeons were significantly longer (P barium sulfate suspension. From the results of this study, we conclude that BIPS are not useful for radiographically evaluating GI transit times in pigeons and are unlikely to be useful in other avian species that have a muscular ventriculus. BIPS may or may not be useful for evaluating GI transit times in species that lack a muscular ventriculus.

  7. Estudo comparativo dos meios de contraste baritado e iodado-iônico e não-iônico no trato respiratório de ratos Comparative study of barium and iodine agents - ionic and nonionic on the respiratory tract of the rats

    Directory of Open Access Journals (Sweden)

    Maria de Lourdes Pessole Biondo-Simões

    2003-10-01

    determine the changes in the respiratory tract triggered by the presence of contrast medium. METHODS: Ninety-one rats were divided at random into 5 groups, i.e., an intact control group of 7 animals and 4 groups of 21 rats each. The manipulated control group received physiological saline and the experimental groups respectively received barium, ionic iodine and non-ionic iodine. Under anesthesia and direct visualization of the trachea, 0.75 ml/kg (0.25 ml of the contrast medium was injected into the animals of each group. The effects of the procedure were determined after 1 hour, 1 day and 1 week, with the animals being sacrificed at each time point by drawing lots. Radiographic documentation was obtained, followed by resection and histopathologic examination of the lungs. RESULTS: After 1 hour, the middle fields and the right upper field were involved in the group injected with barium. In the groups injected with ionic iodine and non-ionic iodine, the entire right lung was found to be opacified. After 1 day and 1 week, the groups injected with iodine were normal, whereas the group injected with barium showed involvement of the middle fields. After 1 week, histopathologic examination revealed that the group injected with barium exhibited large amounts of intra-alveolar, perivascular and peribronchial macrophages CONCLUSION: The ionic and non-ionic iodine contrast media led to temporary changes, whereas barium promoted a chronic inflammatory reaction with maintenance of radiographic translation.

  8. Dynamical symmetry breaking in barium isotopes

    International Nuclear Information System (INIS)

    Rawat, Bir Singh; Chattopadhyay, P.K.

    1997-01-01

    The isotopes of Xe with mass numbers 124, 126, 128, 130 and the isotopes of barium with mass numbers 128, 130, 132, 134 were shown to correspond to the O(6) dynamical symmetry of IBM. In the investigation of the dynamical symmetry breaking in this region, the barium isotopes for departures from O(6) symmetry have been studied

  9. Late changes in barium sulfate aspiration: HRCT features

    International Nuclear Information System (INIS)

    Voloudaki, A.; Ergazakis, N.; Gourtsoyiannis, N.

    2003-01-01

    Aspiration of barium sulfate occurs accidentally. Lung reaction is usually mild in the early phase due to inert character of the substance and long-term reactions or late toxicities are not expected. Little if any fibrotic response is speculated. We present a case with barium aspiration, studied by high-resolution computed tomography (HRCT) 1 year after the event, as late pulmonary sequelae studied by CT have not been described yet, to the best of our knowledge. The HRCT revealed thickened interlobular septa, subpleural lines, subpleural cysts, and centrilobular micronodules along with barium particles in a subpleural distribution. Those findings indicated that barium is capable of producing mild though silent clinically fibrosis. (orig.)

  10. History and Evolution of the Barium Swallow for Evaluation of the Pharynx and Esophagus.

    Science.gov (United States)

    Levine, Marc S; Rubesin, Stephen E

    2017-02-01

    This article reviews the history of the barium swallow from its early role in radiology to its current status as an important diagnostic test in modern radiology practice. Though a variety of diagnostic procedures can be performed to evaluate patients with dysphagia or other pharyngeal or esophageal symptoms, the barium study has evolved into a readily available, non-invasive, and cost-effective technique that can facilitate the selection of additional diagnostic tests and guide decisions about medical, endoscopic, or surgical management. This article focuses on the evolution of fluoroscopic equipment, radiography, and contrast media for evaluating the pharynx and esophagus, the importance of understanding pharyngoesophageal relationships, and major advances that have occurred in the radiologic diagnosis of select esophageal diseases, including gastroesophageal reflux disease, infectious esophagitis, eosinophilic esophagitis, esophageal carcinoma, and esophageal motility disorders.

  11. Safety of Contrast Material Use During Pregnancy and Lactation.

    Science.gov (United States)

    Puac, Paulo; Rodríguez, Andrés; Vallejo, Carina; Zamora, Carlos A; Castillo, Mauricio

    2017-11-01

    The use of contrast media to image patients who are pregnant has increased during the past decades worldwide. Their use in pregnancy and in patients who are lactating remains a challenging issue for radiologists and other physicians. This article addresses the different types of contrast media that may be used in such patients according to the imaging modality (iodinated contrast media, barium, gadolinium-based, and ultrasound contrast agents), focusing on their adverse effects, potential teratogenic effects, strategies to minimize risks, and current clinical recommendation. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

    Science.gov (United States)

    Yeh, Benjamin M; FitzGerald, Paul F; Edic, Peter M; Lambert, Jack W; Colborn, Robert E; Marino, Michael E; Evans, Paul M; Roberts, Jeannette C; Wang, Zhen J; Wong, Margaret J; Bonitatibus, Peter J

    2017-04-01

    The introduction of spectral CT imaging in the form of fast clinical dual-energy CT enabled contrast material to be differentiated from other radiodense materials, improved lesion detection in contrast-enhanced scans, and changed the way that existing iodine and barium contrast materials are used in clinical practice. More profoundly, spectral CT can differentiate between individual contrast materials that have different reporter elements such that high-resolution CT imaging of multiple contrast agents can be obtained in a single pass of the CT scanner. These spectral CT capabilities would be even more impactful with the development of contrast materials designed to complement the existing clinical iodine- and barium-based agents. New biocompatible high-atomic number contrast materials with different biodistribution and X-ray attenuation properties than existing agents will expand the diagnostic power of spectral CT imaging without penalties in radiation dose or scan time. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. SALT reveals the barium central star of the planetary nebula Hen 2-39

    Science.gov (United States)

    Miszalski, B.; Boffin, H. M. J.; Jones, D.; Karakas, A. I.; Köppen, J.; Tyndall, A. A.; Mohamed, S. S.; Rodríguez-Gil, P.; Santander-García, M.

    2013-12-01

    Classical barium stars are binary systems which consist of a late-type giant enriched in carbon and slow neutron capture (s-process) elements and an evolved white dwarf (WD) that is invisible at optical wavelengths. The youngest observed barium stars are surrounded by planetary nebulae (PNe), ejected soon after the wind accretion of polluted material when the WD was in its preceding asymptotic giant branch (AGB) phase. Such systems are rare but powerful laboratories for studying AGB nucleosynthesis as we can measure the chemical abundances of both the polluted star and the nebula ejected by the polluter. Here, we present evidence for a barium star in the PN Hen 2-39 (PN G283.8-04.2) as one of only a few known systems. The polluted giant is very similar to that found in WeBo 1 (PN G135.6+01.0). It is a cool (Teff = 4250 ± 150 K) giant enhanced in carbon ([C/H] = 0.42 ± 0.02 dex) and barium ([Ba/Fe] = 1.50 ± 0.25 dex). A spectral type of C-R3 C24 nominally places Hen 2-39 amongst the peculiar early R-type carbon stars; however, the barium enhancement and likely binary status mean that it is more likely to be a barium star with similar properties, rather than a true member of this class. An AGB star model of initial mass 1.8 M⊙ and a relatively large carbon pocket size can reproduce the observed abundances well, provided mass is transferred in a highly conservative way from the AGB star to the polluted star (e.g. wind Roche lobe overflow). It also shows signs of chromospheric activity and photometric variability with a possible rotation period of ˜5.5 d likely induced by wind accretion. The nebula exhibits an apparent ring morphology in keeping with the other PNe around barium stars (WeBo 1 and A 70) and shows a high degree of ionization implying the presence of an invisible hot pre-WD companion that will require confirmation with UV observations. In contrast to A 70, the nebular chemical abundance pattern is consistent with non-Type I PNe, in keeping with the

  14. Barium low concentration determination in solutions using X rays energy spectrometry

    International Nuclear Information System (INIS)

    Barbosa, Joao Batista Santos; Pereira, Jose dos Santos Jorge

    1999-01-01

    This work was proposed to establish an analytical methodology for barium determination in samples from the Waste Supervision of CDTN. Barium is the focus here because it has the same chemical behaviour as radium. Therefore, barium can replace it as an inactive tracer in contention matrix studies. The methodology is made up of two phases; physical concentration and barium determination by an Energy Dispersive Spectrometer using an Am 241 photon excitation system. A very good set of results is found when Am 241 is used in fluorescing barium atoms. This fact, in addition to the physical concentration process, allows to detect up 12 ppb of elementary barium. (author)

  15. Electrooptic and piezoelectric measurements in photorefractive barium titanate and strontium barium niobate

    International Nuclear Information System (INIS)

    Ducharme, S.; Feinberg, J.; Neurgaonkar, R.R.

    1987-01-01

    The authors measured the low-frequency (''unclamped'') electrooptic and piezoelectric coefficients in undoped BaTiO/sub 3/ and Sr/sub x/Ba/sub 1-x/Nb/sub 2/O/sub 6/ (chi - 0.61) crystals using interferometric techniques. The contribution of the piezoelectric effect to the Pockels measurement is discussed. For an applied ac electric field in the range 0.1-200 V/cm, the electrooptic and piezoelectric effects are linear in the magnitude of of the applied field and independent of its frequency in the range of 10 Hz-100 kHz. The unclamped electrooptic coefficients of poled BaTiO/sub 3/ single crystals are r/sub 13/ = 19.5 +- 1 pm/V and r/sub 33/ = 97 +- 7 pm/V, and for strontium barium niobate are r/sub 13/ = 47 +- 5 pm/V and r/sub 33/ = 235 +- 21 pm/V, all measured at a wavelength of 514.5 nm and at T = 23 0 C. For the barium titanate samples the measured Pockels coefficient r/sub c/ identical to r/sub 33/ - (n/sub 1//n/sub 3/)/sup 3/r/sub 13/ = 79 +- 6 pm/V in good agreement with the value r/sub c/ = 76 +- 7 pm/V computed from the above values of r/sub 13/ and r/sub 33/, where n/sub 1/ and n/sub 3/ are the ordinary and extraordinary indexes of refraction, respectively. The measured piezoelectric coefficient is d/sub 23/ = +28.7 +- 2 pm/V for barium titanate, and is d/sub 23/ = +24.6 +- 2 pm/V for strontium barium niobate. They also measured the photoreflective coupling of two optical beams in the crystals, and they show that the dependence of the coupling strength on beam polarization is in fair agreement with the measured values of the Pockels coefficients

  16. Complementary contrast media for metal artifact reduction in dual-energy computed tomography.

    Science.gov (United States)

    Lambert, Jack W; Edic, Peter M; FitzGerald, Paul F; Torres, Andrew S; Yeh, Benjamin M

    2015-07-01

    Metal artifacts have been a problem associated with computed tomography (CT) since its introduction. Recent techniques to mitigate this problem have included utilization of high-energy (keV) virtual monochromatic spectral (VMS) images, produced via dual-energy CT (DECT). A problem with these high-keV images is that contrast enhancement provided by all commercially available contrast media is severely reduced. Contrast agents based on higher atomic number elements can maintain contrast at the higher energy levels where artifacts are reduced. This study evaluated three such candidate elements: bismuth, tantalum, and tungsten, as well as two conventional contrast elements: iodine and barium. A water-based phantom with vials containing these five elements in solution, as well as different artifact-producing metal structures, was scanned with a DECT scanner capable of rapid operating voltage switching. In the VMS datasets, substantial reductions in the contrast were observed for iodine and barium, which suffered from contrast reductions of 97% and 91%, respectively, at 140 versus 40 keV. In comparison under the same conditions, the candidate agents demonstrated contrast enhancement reductions of only 20%, 29%, and 32% for tungsten, tantalum, and bismuth, respectively. At 140 versus 40 keV, metal artifact severity was reduced by 57% to 85% depending on the phantom configuration.

  17. Rectal Lipoma Associated with Genital Prolapse

    African Journals Online (AJOL)

    female genital prolapse. In the present case, as the patient is post‑menopausal and with co‑existing partial rectal prolapse, vaginal hysterectomy was carried out. Diagnostic approaches usually include endoscopy, contrast‑enhanced CT scan of the abdomen, and barium enema. Endoscopic biopsies usually fail to diagnose ...

  18. Barium and radium migration in unconsolidated Canadian geological materials

    International Nuclear Information System (INIS)

    Gillham, R.W.; Sharma, H.D.; Reddy, M.R.; Cooper, E.L.; Cherry, J.A.

    1981-05-01

    This report describes the results of laboratory studies on the distribution coefficients of radium and barium in samples of unconsolidated geologic materials. Graphs of Ksub(d) versus solution concentration for the respective elements showed constant Ksub(d) values in the low concentration range suggesting that, at low concentrations, a distribution coefficient is a valid means of representing the geochemical reactions of both barium and radium. The Ksub(d) values for barium range between 60 and 3500 ml/g. The values appear to be influenced by the amount of barium occurring naturally in the soil materials and thus there is little possiblility of using barium as an analog of radium in laboratory experiments. The Ksub(d) values of radium vary from 50 to 1000 ml/g indicating that a wide range of geological materials have a substantial capacity to retard the migration of radium

  19. Time requirement for barium reduction in intussusception

    International Nuclear Information System (INIS)

    Hwang, Hye Eun; Kim, Seung Ho; Kang, In Young; Park, Byoung Lan; Kim, Byoung Geun

    1988-01-01

    During the period between January 1985 and December 1987, barium reduction was performed in 146 cases of intussusception who were admitted to Kwangju Christian Hospital. The results were as follows: 1. Success rate to the symptom duration is relatively constant. 2. The success rate in infants with severe dehydration was 50% but it was gradually increased in infants with moderate dehydration and in infants with mild dehydration, 83.3% and 100% respectively. 3. The success rate of 12 cases in severely dehydrated infants with positive dissection sign was 16.7%. 4. The success rate of 15 cases in moderately dehydrated infants with positive dissection sign was 66.7%. 5. The average time requirement for barium reduction was 58.3 minutes. No serious complications were noted during barium reduction, except mild vomiting. 6. With above results, it is desirable that barium reduction should be performed according to the patient's physical status and radiologic findings.

  20. The value of sonography, CT and air enema for detection of complicated Meckel diverticulum in children with nonspecific clinical presentation

    International Nuclear Information System (INIS)

    Daneman, A.; Lobo, E.; Alton, D.J.; Shuckett, B.

    1998-01-01

    Background. Complicated Meckel diverticulum (MD) in children does not always present with painless rectal bleeding and its presentation can then produce a difficult diagnostic dilemma. In this clinical setting, sonography (US), CT or even air enema may be the first modality chosen to evaluate these children rather than the radionuclide Meckel scan (RNMS). Purpose. To assess the value of US, CT and air enema for detection of complicated MD. Materials and methods. Review of clinical, imaging, surgical and pathological findings in 64 children (55 males, 9 females) aged 4 days -14 years (mean = 3.7 years) with MD seen during an 8-year period, 1990-1997. Results. (a) In 33 patients with rectal bleeding, MD was detected on RNMS in 32. Ten of these 32 had other imaging studies, all of which were negative. (b) The other 31 patients, with varied clinical presentations, did not undergo RNMS. In these 31 and the 1 with a negative RNMS, 14 (44 %) had imaging features highly suggestive for the diagnosis of MD on US in all 14, on CT in 1, and on air enema in 3. The radiological spectrum of the inflamed, hemorrhagic MD is illustrated. Conclusion. The inflamed, hemorrhagic and the inverted, intussuscepted MD have a spectrum of features recognizable on US, CT and air enema. Some of these appearances are specific, others are not. Knowledge of and recognition of these features will facilitate detection of complicated MD in larger numbers of children presenting with symptoms other than the classic history of painless rectal bleeding and also in those with normal RNMS. (orig.)

  1. Location and activity of ulcerative and Crohn's colitis by 111In leukocyte scan. A prospective comparison study

    International Nuclear Information System (INIS)

    Stein, D.T.; Gray, G.M.; Gregory, P.B.; Anderson, M.; Goodwin, D.A.; McDougall, I.R.

    1983-01-01

    A prospective blinded study comparing the 111 In leukocyte scan to barium enema, colonoscopy, or surgery or a combination of these, was carried out in 15 patients (10 with active ulcerative colitis and 5 with active Crohn's colitis). Correlation of disease location to colonic regions between indium scan and other diagnostic studies was excellent in 11 instances, good in 2, and poor in 3. In 2 of the 3 studies where major disagreement occurred, the comparative barium enema was performed greater than 2 mo after the indium scan. Disease activity, estimated by the intensity of radionuclide uptake, was compared to clinical disease activity assessed by the Crohn's Disease Activity Index for both forms of colitis. The relative degree of inflammation estimated by the indium scan correlated well with the independent clinical assessment (correlation coefficient . 0.81). The indium 111 leukocyte scan appears to be an accurate, noninvasive method for assessing the extent and the severity of the inflammation in patients with acute ulcerative or Crohn's colitis

  2. Idiopathic incapacitates in infancy and childhood

    International Nuclear Information System (INIS)

    Crankson, Stanley J.; Al-Rabeeh, Abdulla A.; Fischer, James D.; Al-Jaddan, Saud A.

    2003-01-01

    Idiopathic intussusception is an important cause of abdominal pain, bleeding per rectum and intestinal obstruction in infancy and childhood. The main aim of this study was to undertake a retrospective review of all chidren who presented with idiopathic intussusception over a 17-year period. The medical record of children who presented idiopathic intussusception from January 1984 to December 2000 at King Fahad National Guard Hospital ,Riyadh, Kingdom of Saudi Arabia were reviewed. The data obtained included age, sex clincal presentation, diagonstic investigations, mode of treatment, length of hospital stay and results. Thirty-three chidren (21 male, 12female) presented with 37 episodes of intussusception.Their mean age was 8.4 months (range 5 hours to 36 months ). Clinical features included rectal bleeding (81%), vomiting (78%), abdominal colic/pain (65%) and abdominal mass (62%) .All cases were ileocolic intussusception with no leading point. Barium enema was attempted in 36 cases with success in 20 (56%). Laparotomy was required in 16 csaes, manual reduction being successful in 11(30%) and 6 (16%) had bowel resection. At surgery, after attempted Barium reduction, 9(56%) cases had the intussusception already reduced to cecum. Seventy percent of the cases presented within 24 hours of onset of the symptoms.The 4 recurrences in 3 children had successful enema reduction. There was no mortality but 3 operative cases of this type required late surgery for adhesive intestinal obstruction including one requiring bowel resection. Idiopathic indussusception commonly presents as an ileo-colic type but is uncommon in our institution. The clinical features are classical, rectal bleeding being the most common. The majority presented within 24 hours of onset of symptoms and Barium enema reduction was sucessfull in 20 out of 36 cases in which it was attempted . Since most intussusception were already in the cecum at surgey after failed enema reduction could be considerd in stable

  3. Diagnostic miss rate for colorectal cancer: an audit.

    Science.gov (United States)

    Than, Mary; Witherspoon, Jolene; Shami, Javed; Patil, Prachi; Saklani, Avanish

    2015-01-01

    Colorectal cancer (CRC) is a common cancer worldwide. While screening improves survival, avoiding delayed diagnosis in symptomatic patients is crucial. Computed tomographic colonography (CTC) or colonoscopy is recommended as first-line investigation and most societies recommend counseling patients undergoing colonoscopy about a miss rate of 5%. This audit evaluates "miss rate" of colorectal investigations, which have led to diagnostic delay in symptomatic cases in a district general hospital in the United Kingdom. This is a retrospective review of 150 consecutive CRC cases presenting between August 2010 and July 2011. Evidence of bowel investigations done in the 3 years prior to diagnosis was obtained from computerized health records. Data regarding previous bowel investigations such as colonoscopy, CTC, double contrast barium enema (DCBE), and CT abdomen/pelvis were collected. 6.7% cases were identified via screening pathway while 93% were identified through symptomatic pathway. 17% (26/150) of newly diagnosed CRC had been investigated in the preceding 3 years. Of these, 8% (12/150) had false negative results. The false negative rate for CRC diagnosis was 3.5% for colonoscopy (3/85), 6.7% for CTC (1/17), 9.4% for CT (5/53), and 26.7% for DCBE (4/15). Some patients had a missed diagnosis despite more than one diagnostic test. Time delay to diagnosis ranged from 21-456 days. 17% of patients diagnosed with CRC had been investigated in the previous 3 years. Higher miss rate of barium enema should preclude its use as a first-line modality to investigate CRC.

  4. Comparative study of pneumocystography, positive contrast cystography and double contrast cystography in dogs

    International Nuclear Information System (INIS)

    Thibaut, J.; Parada, E.; Vargas, L.; Deppe, R.; Born, R.

    1997-01-01

    In order to compare three radiographic techniques: pneumocystography, positive contrast cystography and double contrast cystography, three series of 24 radiographs each in lateral and ventrodorsal projections were made. Six healthy adult male dogs with weight ranging between 7 and 16 kg were used. Food was withheld for 24 hours and two enemas were made before the series of radiographs were taken. Dogs were anaesthetized with sodium thiopental (20 mg/kg i.v.). The contrast medium was introduced through a urethral catheter. Pneumocystography was performed in the first series introducing air (10 ml/kg) in the bladder. Positive contrast cystography was performed in the second series introducing Hypaque M-60% diluted, contributing 100 mg of iodine per ml (10 ml/kg). In the double contrast cystography Hypaque M-60% diluted (10 ml) was introduced, in concentration of 150 mg of iodine per ml. Then air was introduced (10 ml/kg) through a catheter. Plates were taken in both projections at 1 and 10 minutes for each technique. The radiographic plates of each series were analized comparing the characteristics of radiographic density, outline and size. In neumocystography, positive contrast and double contrast cystography, the radiographic density was predominantly low, high and intermediate, respectively. The radiographic outline was mainly regular for the three techniques. With respect to bladder size, there was a decrease of height and an increase of length and width at 10 minutes. Comparing these three radiographic techniques, it can be concluded that the one that best outlines the bladder mucosa is double contrast. Pneumocystography provides the best image for opaque structures and cystography best shows the position of the urinary bladder [es

  5. Surface studies of barium and barium oxide on tungsten and its application to understanding the mechanism of operation of an impregnated tungsten cathode

    Science.gov (United States)

    Forman, R.

    1976-01-01

    Surface studies have been made of multilayer and monolayer films of barium and barium oxide on a tungsten substrate. The purpose of the investigation was to synthesize the surface conditions that exist on an activated impregnated tungsten cathode and obtain a better understanding of the mechanism of operation of such cathodes. The techniques employed in these measurements were Auger spectroscopy and work-function measurements. The results of this study show that the surface of an impregnated cathode is identical to that observed for a synthesized monolayer or partial monolayer of barium on oxidized tungsten by evaluating Auger spectra and work-function measurements. Data obtained from desorption studies of barium monolayers on a tungsten substrate in conjunction with Auger and work-function results have been interpreted to show that throughout most of its life an impreganated cathode has a partial monolayer, rather than a monolayer, of barium on its surface.

  6. Primary lymphoma of appendix: Ultrasound finding

    International Nuclear Information System (INIS)

    Sotillos Parra, V.E.; Belda Serrano, J.; Mota Castilla, A.; Falomir Gil, G.; Abreu Maqueda, V.; Trigueris Sanchez, M.; Hernandez Barcelo, J.E.; Martinez Diaz, F.

    1994-01-01

    We present an uncommon case of primary lymphoma of the appendix in a patient who complained of discomfort in lower right quadrant. The findings revealed by ultrasound, barium enema and CT scan are reported and the diagnostic aspects of this appendiceal tumor and others are discussed. (Author) 6 refs

  7. Colonic duplication in an adult

    International Nuclear Information System (INIS)

    Baro, P.; Dario Casas, J.; Sanchez, D.

    1988-01-01

    A case of colonic duplication that was diagnosed radiologically in an adult is reported. A long duplicated segment below the normal transverse colon, with a wide anastomosis at the hepatic flexure level, was observed on barium enema. The rarity of this anomaly unassociated with other malformations is emphasized. (orig.)

  8. Colonileus som komplikation til spontant diafragmahernie

    DEFF Research Database (Denmark)

    Svolgaard, Olivia; Burcharth, Flemming

    2009-01-01

    is made clinically by means of thoracic X-ray, computer tomography or magnetic resonance imagining of the abdomen. In this patient, barium enema showed a tumor-like stenosis of the left colonic flexure, but intraoperative findings demonstrated a defect in the left diaphragm with herniation of the left...

  9. Effects of chemesthetic stimuli mixtures with barium on swallowing apnea duration.

    Science.gov (United States)

    Todd, J Tee; Butler, Susan G; Plonk, Drew P; Grace-Martin, Karen; Pelletier, Cathy A

    2012-10-01

    This study tested the hypotheses that swallowing apnea duration (SAD) will increase given barium versus water, chemesthetic stimuli (i.e., water barium, age (older > younger), and genetic taste differences (supertasters > nontasters). Prospective group design. University Medical Center. Eighty healthy women were identified as nontasters and supertasters, equally comprising two age groups: 18 to 35 years and 60+ years. The KayPentax Swallowing Signals Lab was used to acquire SAD via nasal cannula during individually randomized swallows of 5 mL barium, 2.7% w/v citric acid with barium, carbonation with barium, and 50:50 diluted ethanol with barium. Data were analyzed using path analysis, with the mediator of chemesthetic perception, adjusted for repeated measures. Significant main effects of age (P = .012) and chemesthetic stimuli (P = .014) were found, as well as a significant interaction between chemesthetic stimuli and age (P = .028). Older women had a significantly longer SAD than younger women. Post hoc analyses revealed that barium mixed with ethanol elicited a significantly longer SAD than other bolus conditions, regardless of age group. There were no significant differences in SAD between barium and water conditions, and no significant effect of chemesthetic perception (P > .05). Ethanol added to barium elicited longer SAD compared to plain barium, but not the other chemesthetic conditions. Older women had a longer SAD than younger women in all conditions. These findings may influence design of future studies examining effects of various stimuli on SAD. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  10. Post-mortem computed tomography angiography utilizing barium sulfate to identify microvascular structures : a preliminary phantom model and case study

    NARCIS (Netherlands)

    Haakma, Wieke; Rohde, Marianne; Kuster, Lidy; Uhrenholt, Lars; Pedersen, Michael; Boel, Lene Warner Thorup

    2016-01-01

    We investigated the use of computer tomography angiography (CTA) to visualize microvascular structures in a vessel-mimicking phantom and post-mortem (PM) bodies. A contrast agent was used based on 22% barium sulfate, 20% polyethylene glycol and 58% distilled water. A vessel-mimicking phantom

  11. Contrast Agents for Micro-Computed Tomography of Microdamage in Bone

    National Research Council Canada - National Science Library

    Roeder, Ryan K

    2008-01-01

    ...) and contrast agents with higher x-ray attenuation than bone. The ability to detect the presence and to a limited extent the morphology of microdamage in cortical and trabecular bone using micro-CT was demonstrated using a barium sulfate (BaSO4) stain...

  12. Regeneration of barium carbonate from barium sulphide in a pilot-scale bubbling column reactor and utilization for acid mine drainage

    CSIR Research Space (South Africa)

    Mulopo, J

    2012-01-01

    Full Text Available Batch regeneration of barium carbonate (BaCO3) from barium sulphide (BaS) slurries by passing CO2 gas into a pilot-scale bubbling column reactor under ambient conditions was used to assess the technical feasibility of BaCO3 recovery in the Alkali...

  13. Use of carbon dioxide as an intravascular contrast agent: A review of current literature

    OpenAIRE

    Ali, Fahad; Mangi, Muhammad Asif; Rehman, Hiba; Kaluski, Edo

    2017-01-01

    Use of X-ray contrast allows us to differentiate between two or more adjacent structures on radiographic studies. The X-ray contrast agent can be the one with increase X-ray absorption, like iodine and a barium X-ray contrast agent or the one with decrease X-ray absorption like air and carbon dioxide contrast agent. Each contrast agent possesses different risks and benefits in various ways. Carbon dioxide as an intravascular contrast agent can be used as an alternative intravascular contrast ...

  14. Evaluation of radiation dose to pediatric patients during certain special procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Alzimami, K.; Elhag, B.; Babikir, E.; Alsafi, K.

    2014-01-01

    This study was intended to measure pediatric entrance surface air kerma (ESAK) and effective dose during micturating cystourethrography (MCU), intravenous urography (IVU) and barium studies (barium meal, enema, and swallow) and to propose a local diagnostic reference level (DRL). ESAK was measured for patients using calibrated thermoluminescent dosimeters (TLDs, GR200A). Effective doses (E) were calculated using the National Radiological Protection Board (NRPB) software. A total of 236 special pediatric procedures were investigated. 21.7% of the sample comprised barium procedures, 18.6% were MCU procedures while 59.5% of the sample were IVU procedures. The mean ESAK measurements (mGy) were 2.1±0.8, 3.0±23 and 1.2±0.2 for barium meal, enema and swallow in the same order. The mean patient dose for IVU procedures was 12.4±8.7 mGy per procedure and the mean patient dose per MCU procedure was 5.8±7 mGy. Local DRLs were proposed for all procedures. The patient doses in this study are within the reported values, suggesting that pediatric patients are adequately protected. - Highlights: • Pediatric radiation dose has been evaluated for three of the most common fluoroscopic procedures. • Radiation doses were measured using calibrated TLD GR200A. • Pediatric patients of concern and ESAK doses showed large variations. • The patient doses in this study are within the reported studies suggesting that the pediatric patients are adequately protected

  15. Computerized tomography - its validity in the diagnosis of gastroenterologic disease

    International Nuclear Information System (INIS)

    Schoppe, W.D.; Jungblut, R.M.

    1982-01-01

    The development of faster CT-machines with scantimes below five seconds and the introduction of different techniques for CT examinations (e.g. application of oral and intravenous contrast material) have influenced diagnostic procedures in medicine. On the other hand there are only a few procedures that have been replaced by CT, e.g. pneumoventriculography, pneumoretroperitoneum. In gastronenterology well established diagnostic methods as ultrasound, ERCP, PTC, barium meal and barium enema are known to have a high accuracy. CT has to be compared with these techniques and therefore its value in the diagnostic spectrum is still under investigation. So far every single method has primary or secondary indications. But it should be the aim of further studies to minimize risk and radiation dose of diagnostic procedures. Using CT this is possible, especially in intraabdominal diseases. From the present knowledge the validity of CT in the diagnosis of gastroenterologic diseases is discussed. The given recommendations might change in the future as result of ongoing investigations, technical improvements, wider distribution of CT machines and broader experiences of physicians. (orig.) [de

  16. Radiological evaluation of surgical emergencies in neonate

    International Nuclear Information System (INIS)

    Suh, C. O.; Oh, K. K.; Park, C. Y.

    1980-01-01

    Most pathologic conditions requiring emergent operation in neonate are congenital anomalies and delayed diagnosis and associated anomaly are important factors which have contributed to the high mortality rate of congenital anomalies. To prevent this delay, early recognition of the danger signals, adequate roentagenologic examination and accurate diagnosis should be made. Furthermore radiologists should be aware of developing mechanism, clinical manifestations and roentgenographic findings of those neonatal emergencies. 135 cases of neonatal emergencies were analyzed at this point of view, which verified by surgery and pathologic examination at Yonsei University College of Medicine, Severance Hospital since 1968. Embryology and characteristic roentgenographic pictures of each disease were discussed. The conclusions are as follows; 1. Most cases (110/135) presented intestinal obstruction. Imperforate anus (29 cases) was most common disease which followed by infantile hypertrophic pyloric stenosis (25 cases), small bowel atresia and stenosis (18 cases), congenital megacolon (15 cases) and esophageal atresia (14 cases). 2. Clinical Type and time of occurrence of symptoms and signs were so characteristic that these were helpful for differential diagnosis. 3. In infantile hypertrophic pyloric stenosis, confirmative diagnosis could be made in plain abdominal film, when 'Caterpillar sign' was seen. 4. When small bowel obstruction was suspected in plain abdominal film, barium enema examination was more helpful than upper G-I study. When microcolon was found, lower small bowel obstruction was highly suggested. 5. Diagnosis of midgut malrotation was possible in larger cases (4/7). Upper G-I examination was more valuable than barium enema study, because duodenal obstruction due to Ladd's band was common problem in neonate. 6. In neonatal period, diagnosis of aganglionosis could be made with the finding of barium stasis on 24-48 hours delay film, even though no demonstration of

  17. Influence of barium sulfate X-ray imaging contrast material on properties of floating drug delivery tablets.

    Science.gov (United States)

    Diós, Péter; Szigeti, Krisztián; Budán, Ferenc; Pócsik, Márta; Veres, Dániel S; Máthé, Domokos; Pál, Szilárd; Dévay, Attila; Nagy, Sándor

    2016-12-01

    The objective of the study was to reveal the influence of necessarily added barium sulfate (BaSO 4 ) X-ray contrast material on floating drug delivery tablets. Based on literature survey, a chosen floating tablet composition was determined containing HPMC and carbopol 943P as matrix polymers. One-factor factorial design with five levels was created for evaluation of BaSO 4 (X 1 ) effects on experimental parameters of tablets including: floating lag time, total floating time, swelling-, erosion-, dissolution-, release kinetics parameters and X-ray detected volume changes of tablets. Applied concentrations of BaSO 4 were between 0 and 20.0% resulting in remarkable alteration of experimental parameters related especially to flotation. Drastic deterioration of floating lag time and total floating time could be observed above 15.0% BaSO 4 . Furthermore, BaSO 4 showed to increase the integrity of tablet matrix by reducing eroding properties. A novel evaluation of dissolutions from floating drug delivery systems was introduced, which could assess the quantity of drug dissolved from dosage form in floating state. In the cases of tablets containing 20.0% BaSO 4 , only the 40% of total API amount could be dissolved in floating state. In vitro fine resolution X-ray CT imagings were performed to study the volume change and the voxel distributions as a function of HU attenuations by histogram analysis of the images. X-ray detected relative volume change results did not show significant difference between samples. After 24h, all tablets containing BaSO 4 could be segmented, which highlighted the fact that enough BaSO 4 remained in the tablets for their identification. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Barium Depletion in the NSTAR Discharge Cathode After 30,000 Hours of Operation

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2010-01-01

    Dispenser hollow cathodes rely on a consumable supply of barium released by impregnant materials in the pores of a tungsten matrix to maintain a low work function surface. Examinations of cathode inserts from long duration ion engine tests show deposits of tungsten at the downstream end that appear to block the flow of barium from the interior. In addition, a numerical model of barium transport in the insert plasma indicates that the barium partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant barium-producing reaction, and it was postulated previously that this would suppress barium loss in the upstream part of the insert. New measurements of the depth of barium depletion from a cathode insert operated for 30,352 hours reveal that barium loss is confined to a narrow region near the downstream end, confirming this hypothesis.

  19. Evaluation of barium hydroxide treatment efficacy on a dolomitic marble.

    Science.gov (United States)

    Toniolo, L; Colombo, C; Realini, M; Peraio, A; Positano, M

    2001-01-01

    The Arch of Peace, by Luigi Cagnola, is one of the most famous neoclassical monuments in Milan. It has been subjected to conservative intervention in 1998. In the present paper the efficacy of the consolidation by means of barium hydroxide has been evaluated. The stone material showed severe degradation phenomena as: erosion, pulverisation, exfoliation. The analytical data acquired through X-ray diffraction (XRD), infrared spectrophotometry (FTIR) and scanning electron microscopy (SEM-EDX), allowed to compare the conditions of stone before and after the treatment with barium hydroxide. The presence of barium has been put in evidence mainly on the surface as barium sulphate, whereas barium is only sporadically present within the thickness of the decayed material. The treatment was judged not satisfying and its inefficacy is, most probably, due to a not suitable cleaning procedure carried out before the consolidation.

  20. EVALUATION OF ENEMAS CONTAINING SUCRALFATE IN TISSUE CONTENT OF MUC-2 PROTEIN IN EXPERIMENTAL MODEL OF DIVERSION COLITIS.

    Science.gov (United States)

    Fernandez, Oscar Orlando Araya; Pereira, José Aires; Campos, Fábio Guilherme; Araya, Carolina Mardegan; Marinho, Gabriele Escocia; Novo, Rafaela de Souza; Oliveira, Thais Silva de; Franceschi, Yara Tinoco; Martinez, Carlos Augusto Real

    2017-01-01

    The effects of topical application of sucralfate (SCF) on the tissue content of MUC-2 protein have not yet been evaluated in experimental models of diversion colitis. To measure the tissue content of MUC-2 protein in the colonic mucosa diverted from fecal stream submitted to the SCF intervention. Thirty-six rats underwent derivation of intestinal transit through proximal colostomy and distal mucous fistula. The animals were divided into three groups which were submitted application of enemas with saline, SCF 1 g/kg/day and SCF 2 g/kg/day. Each group was divided into two subgroups, according to euthanasia was done after two or four weeks. The colitis diagnosis was established by histopathological study and the inflammatory intensity was evaluated by previously validated scale. The MUC-2 protein was identified by immunohistochemistry and the tissue content was measured computerized morphometry). The application of enemas with SCF in the concentration of 2 g/kg/day reduced inflammatory score of the segments that were diverted from fecal stream. The content of MUC-2 in diverted colon of the animals submitted to the intervention with SCF, independently of intervention period and the used concentration, was significantly greater than animals submitted to the application of enemas containing saline (p< 0.01). The content of MUC-2 after the intervention with SCF in the concentration of 2 g/kg/day was significantly higher when compared to the animals submitted to the application containing SCF at concentration of 1.0 g/kg/day (p<0.01). The tissue content of MUC-2 reached the highest values after intervention with SCF in the concentration of 2 g/kg/day for four weeks (p<0.01). Conclusion: The preventive application of enemas containing SCF reduces the inflammatory score and avoids the reduction of tissue content of MUC-2, suggesting that the substance is a valid therapeutic strategy to preserve the mucus layer that covers the intestinal epithelium.

  1. Initial experience with magnetic resonance fluoroscopy in the evaluation of oesophageal motility disorders. Comparison with manometry and barium fluoroscopy

    International Nuclear Information System (INIS)

    Panebianco, Valeria; Anzidei, Michele; Catalano, Carlo; Passariello, Roberto; Habib, Fortunee I.; Tomei, Ernesto; Paolantonio, Pasquale; Laghi, Andrea

    2006-01-01

    The aim of this paper was to assess the diagnostic value of magnetic resonance (MR) fluoroscopy in the study of oesophageal motility disorders and to compare MR fluoroscopy results with those of manometry and barium contrast radiography. Twenty-five subjects referred for dysphagia and three patients in follow-up after pneumatic dilatation of the lower oesophageal sphincter to treat severe achalasia underwent esophageal manometry, barium contrast radiography and MR fluoroscopy. Examinations were performed on a 1.5 T scanner. Dynamic turbo- fast low angle shot (turbo-FLASH) sequences acquired during oral contrast agent administration were used to perform MR fluoroscopy. MR fluoroscopy correctly diagnosed achalasia in nine patients, uncoordination of esophageal body motility in ten and scleroderma oesophagus in one. Diagnostic performance was satisfactory, with a sensitivity of 87.5% and a specificity of 100% in the general depiction of motility alterations. Our work demonstrates that MR fluoroscopic examination in subject affected by oesophageal motility disorders is feasible and can properly depict motility and morphology alterations, achieving correct diagnosis in the majority of cases. Studies on larger populations are necessary to obtain statistically significant results. (orig.)

  2. Initial experience with magnetic resonance fluoroscopy in the evaluation of oesophageal motility disorders. Comparison with manometry and barium fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Panebianco, Valeria; Anzidei, Michele; Catalano, Carlo; Passariello, Roberto [University of Rome ' ' La Sapienza' ' , Department of Radiological Sciences, Rome (Italy); Habib, Fortunee I.; Tomei, Ernesto [University of Rome ' ' La Sapienza' ' , Division of Gastroenterology, Rome (Italy); Paolantonio, Pasquale; Laghi, Andrea [University of Rome ' ' La Sapienza' ' , Department of Radiological Sciences - Polo Didattico Pontino I.C.O.T, Rome (Italy)

    2006-09-15

    The aim of this paper was to assess the diagnostic value of magnetic resonance (MR) fluoroscopy in the study of oesophageal motility disorders and to compare MR fluoroscopy results with those of manometry and barium contrast radiography. Twenty-five subjects referred for dysphagia and three patients in follow-up after pneumatic dilatation of the lower oesophageal sphincter to treat severe achalasia underwent esophageal manometry, barium contrast radiography and MR fluoroscopy. Examinations were performed on a 1.5 T scanner. Dynamic turbo- fast low angle shot (turbo-FLASH) sequences acquired during oral contrast agent administration were used to perform MR fluoroscopy. MR fluoroscopy correctly diagnosed achalasia in nine patients, uncoordination of esophageal body motility in ten and scleroderma oesophagus in one. Diagnostic performance was satisfactory, with a sensitivity of 87.5% and a specificity of 100% in the general depiction of motility alterations. Our work demonstrates that MR fluoroscopic examination in subject affected by oesophageal motility disorders is feasible and can properly depict motility and morphology alterations, achieving correct diagnosis in the majority of cases. Studies on larger populations are necessary to obtain statistically significant results. (orig.)

  3. SEPARATION OF BARIUM VALUES FROM URANYL NITRATE SOLUTIONS

    Science.gov (United States)

    Tompkins, E.R.

    1959-02-24

    The separation of radioactive barium values from a uranyl nitrate solution of neutron-irradiated uranium is described. The 10 to 20% uranyl nitrate solution is passed through a flrst column of a cation exchange resin under conditions favoring the adsorption of barium and certain other cations. The loaded resin is first washed with dilute sulfuric acid to remove a portion of the other cations, and then wash with a citric acid solution at pH of 5 to 7 to recover the barium along with a lesser amount of the other cations. The PH of the resulting eluate is adjusted to about 2.3 to 3.5 and diluted prior to passing through a smaller second column of exchange resin. The loaded resin is first washed with a citric acid solution at a pH of 3 to elute undesired cations and then with citric acid solution at a pH of 6 to eluts the barium, which is substantially free of undesired cations.

  4. Prompt striations observed in a barium thermite release at 335 km

    International Nuclear Information System (INIS)

    Simons, D.J.; Pongratz, M.B.; Smith, G.M.; Barasch, G.E.; Fitzgerald, T.J.

    1981-01-01

    Three barium clouds have been released from a single rocket at altitudes of 335, 443, and 535 km. The releases were by means of barium thermite injection. Adding the different cross-field velocity components of the rocket at each of the releases resulted in barium clouds with different kinetic velocity distributions. The barium cloud with the most peaked velocity distribution striated promptly, in good agreement with theoretical predictions based on a kinetic plasma instability. Details of the data analysis and experiment are discussed

  5. Colonic angiodysplasia on CT colonography: case report and characteristic imaging findings

    Directory of Open Access Journals (Sweden)

    Laura Filograna, MD

    2017-12-01

    Full Text Available Gastrointestinal angiodysplasia represents the cause of 6% of lower gastrointestinal tract bleeding, particularly in the elderly. Because of the common presentation and age range of affected patients, often patients with occult or massive gastrointestinal bleedings are investigated with colonoscopy, in the suspect of colonic cancer. Other methods are capsule enteroscopy, angiography, double-contrast barium enema, computed tomography angiography, and radionuclide scanning. In this contribution, we describe a case of colonic angiodysplasia first suspected during computed tomography colonography performed after an incomplete colonoscopy in a patient with recent anemization. The purpose is to highlight the computed tomography colonography imaging characteristics of this rare finding during such examination performed due to suspected colon carcinoma as a complementary or substitutive method of colonoscopy.

  6. Absorbed dose to the skin in radiological examinations of upper and lower gastrointestinal tract

    International Nuclear Information System (INIS)

    Zonca, G.; Brusa, A.; Somigliana, A.; Pasqualotto, C.; Sichirollo, A.E.; Bellomi, M.; Cozzi, G.; Severini, A.

    1995-01-01

    Absorbed doses to the skin in radiological examinations of the upper and lower gastronintestinal tract in conventional and digital radiology are evaluated and compared. Absorbed doses were measured with LiF thermoluminescence dosemeters placed on the lower pelvis, umbilicus and forehead of the patient to evaluate the absorbed dose in and outside the primary beam. On 10 patients a reduction in absorbed dose of about 34% for double contrast barium enema and of 66% for upper gastrointestinal tract examinations was revealed with digital radiography equipment. In our working conditions the lower dose requirement for digital radiography is mainly due to image intensifiers and television chains and also, due to our equipment settings, to the dose reduction with digital spot fluorography compared with conventional spot film radiography. (Author)

  7. Exposure to low-dose barium by drinking water causes hearing loss in mice.

    Science.gov (United States)

    Ohgami, Nobutaka; Hori, Sohjiro; Ohgami, Kyoko; Tamura, Haruka; Tsuzuki, Toyonori; Ohnuma, Shoko; Kato, Masashi

    2012-10-01

    We continuously ingest barium as a general element by drinking water and foods in our daily life. Exposure to high-dose barium (>100mg/kg/day) has been shown to cause physiological impairments. Direct administration of barium to inner ears by vascular perfusion has been shown to cause physiological impairments in inner ears. However, the toxic influence of oral exposure to low-dose barium on hearing levels has not been clarified in vivo. We analyzed the toxic influence of oral exposure to low-dose barium on hearing levels and inner ears in mice. We orally administered barium at low doses of 0.14 and 1.4 mg/kg/day to wild-type ICR mice by drinking water. The doses are equivalent to and 10-fold higher than the limit level (0.7 mg/l) of WHO health-based guidelines for drinking water, respectively. After 2-week exposure, hearing levels were measured by auditory brain stem responses and inner ears were morphologically analyzed. After 2-month exposure, tissue distribution of barium was measured by inductively coupled plasma mass spectrometry. Low-dose barium in drinking water caused severe hearing loss in mice. Inner ears including inner and outer hair cells, stria vascularis and spiral ganglion neurons showed severe degeneration. The Barium-administered group showed significantly higher levels of barium in inner ears than those in the control group, while barium levels in bone did not show a significant difference between the two groups. Barium levels in other tissues including the cerebrum, cerebellum, heart, liver and kidney were undetectably low in both groups. Our results demonstrate for the first time that low-dose barium administered by drinking water specifically distributes to inner ears resulting in severe ototoxicity with degeneration of inner ears in mice. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Barium Titanate Nanoparticles for Biomarker Applications

    International Nuclear Information System (INIS)

    Matar, O; Hondow, N S; Brydson, R M D; Milne, S J; Brown, A P; Posada, O M; Wälti, C; Saunders, M; Murray, C A

    2015-01-01

    A tetragonal crystal structure is required for barium titanate nanoparticles to exhibit the nonlinear optical effect of second harmonic light generation (SHG) for use as a biomarker when illuminated by a near-infrared source. Here we use synchrotron XRD to elucidate the tetragonal phase of commercially purchased tetragonal, cubic and hydrothermally prepared barium titanate (BaTiO 3 ) nanoparticles by peak fitting with reference patterns. The local phase of individual nanoparticles is determined by STEM electron energy loss spectroscopy (EELS), measuring the core-loss O K-edge and the Ti L 3 -edge energy separation of the t 2g , e g peaks. The results show a change in energy separation between the t 2g and e g peak from the surface and core of the particles, suggesting an intraparticle phase mixture of the barium titanate nanoparticles. HAADF-STEM and bright field TEM-EDX show cellular uptake of the hydrothermally prepared BaTiO 3 nanoparticles, highlighting the potential for application as biomarkers. (paper)

  9. Neutral barium cloud evolution at different altitudes

    International Nuclear Information System (INIS)

    Li Lei; Xu Ronglan

    2002-01-01

    Considering the joint effects of diffusion, collision, oxidation and photoionization, the authors study the evolution of the barium cloud at different altitudes in the space plasma active experiment. The results present the variation of the loss rate, number density distribution and brightness of the barium cloud over the range from 120 to 260 km. This can be divided into oxidation, oxidation plus photoionization and photoionization regions

  10. Fabrication and properties of yttrium doped barium titanate film by RF sputtering

    International Nuclear Information System (INIS)

    Igarashi, H.; Yuasa, M.; Okazaki, K.

    1985-01-01

    Semiconductive barium titanate films were fabricated by RF sputtering on fused quartz, alumina and barium titanate ceramic substrates using barium titanate ceramic with a small amount of yttria as a target. The films on the barium titanate substrates turned blue color and showed a small PTC effect by heat-treating at 1000 0 C in the air after deposition at the substrate temperature of 600 0 C

  11. Gastrointestinal digital fluoroscopy: Comparison of digital pulsed progressive readout images with 100-mm spot films

    International Nuclear Information System (INIS)

    Steiner, E.; Ferrucci, J.T.; Mueller, P.R.; Hahn, P.F.

    1987-01-01

    New developments in pulsed progressive readout (PPR) techniques allow short, extremely intense pulses of radiation to be used to produce a latent image which is then progressively read off the video camera and placed in 1,024 x 1,024-pixel digital storage. The resulting image is produced by a 10-20-msec pulse, reducing motion artifact to below that achievable with conventional spot film techniques, with a potential for 50%-95% dose reduction. This technique of reducing motion artifact is ideal for digital applications in gastrointestinal radiology. The authors compared 10-mm spot films and PPR digital radiographs of 86 anatomic regions in 43 patients undergoing routine barium enema and cholangiographic examinations. Parameters evaluated included display of normal and pathologic features, image contrast, and resolution. The benefits of the PPR technique include postprocessing to evaluate low contrast region and the potential for significant dose reduction

  12. Barium and Tc-poor S stars: Binary masqueraders among carbon stars

    OpenAIRE

    Jorissen, A.; Van Eck, S.

    1997-01-01

    The current understanding of the origin of barium and S stars is reviewed, based on new orbital elements and binary frequencies. The following questions are addressed: (i) Is binarity a necessary condition to produce a barium star? (ii) What is the mass transfer mode (wind accretion or RLOF?) responsible for their formation? (iii) Do barium stars form as dwarfs or as giants? (iv) Do barium stars evolve into Tc-poor S stars? (v) What is the relative frequency of Tc-rich and Tc-poor S stars?

  13. Freeze cast porous barium titanate for enhanced piezoelectric energy harvesting

    Science.gov (United States)

    Roscow, J. I.; Zhang, Y.; Kraśny, M. J.; Lewis, R. W. C.; Taylor, J.; Bowen, C. R.

    2018-06-01

    Energy harvesting is an important developing technology for a new generation of self-powered sensor networks. This paper demonstrates the significant improvement in the piezoelectric energy harvesting performance of barium titanate by forming highly aligned porosity using freeze casting. Firstly, a finite element model demonstrating the effect of pore morphology and angle with respect to poling field on the poling behaviour of porous ferroelectrics was developed. A second model was then developed to understand the influence of microstructure-property relationships on the poling behaviour of porous freeze cast ferroelectric materials and their resultant piezoelectric and energy harvesting properties. To compare with model predictions, porous barium titanate was fabricated using freeze casting to form highly aligned microstructures with excellent longitudinal piezoelectric strain coefficients, d 33. The freeze cast barium titanate with 45 vol.% porosity had a d 33  =  134.5 pC N‑1 compared to d 33  =  144.5 pC N‑1 for dense barium titanate. The d 33 coefficients of the freeze cast materials were also higher than materials with uniformly distributed spherical porosity due to improved poling of the aligned microstructures, as predicted by the models. Both model and experimental data indicated that introducing porosity provides a large reduction in the permittivity () of barium titanate, which leads to a substantial increase in energy harvesting figure of merit, , with a maximum of 3.79 pm2 N‑1 for barium titanate with 45 vol.% porosity, compared to only 1.40 pm2 N‑1 for dense barium titanate. Dense and porous barium titanate materials were then used to harvest energy from a mechanical excitation by rectification and storage of the piezoelectric charge on a capacitor. The porous barium titanate charged the capacitor to a voltage of 234 mV compared to 96 mV for the dense material, indicating a 2.4-fold increase that was similar to that

  14. Radiation losses in microwave K_u region by conducting pyrrole/barium titanate and barium hexaferrite based nanocomposites

    International Nuclear Information System (INIS)

    Kaur, Talwinder; Kumar, Sachin; Narang, S.B.; Srivastava, A.K.

    2016-01-01

    Nanocomposites of substituted barium hexaferrite and barium titanate embedded in a polymer were synthesized via emulsion polymerization. The study was performed by using X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy, electron spin resonance spectroscopy, a vibrating sample magnetometer and a vector network analyzer. It is found that maximum radiation loss occur at 16.09 GHz (−14.23 dB) frequency owing to the combined effect of conducting polymer, suitable dielectric and magnetic material. This suggests that prepared material is suitable for radiation losses. Micro structural study reveals the presence of all the phases of the compounds comprises composite. Benzene ring absorption band (at 1183 cm"−"1) in FT-IR spectra illustrates the presence of polymer. Surface morphology reveals the presence of array of particles encapsulated by the polymer. - Highlights: • Composites having polymer, barium titanate and hexaferrite have been successfully prepared. • Effective radiation absorption and losses have been achieved. • Magnetic properties have made an impact on shielding effectiveness.

  15. Barium uranyl diphosphonates

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Anna-Gay D., E-mail: nelsoa@umich.edu [Department of Civil Engineering and Geological Sciences and Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556 (United States); Department of Earth and Environmental Sciences, University of Michigan, Ann Arbor, MI 48109-1005 (United States); Alekseev, Evgeny V. [Institute of Energy and Climate Research (IEK-6), Forschungszentrum Juelich Wilhelm-Johnen-Strasse, Juelich 52428 (Germany); Ewing, Rodney C. [Department of Earth and Environmental Sciences, University of Michigan, Ann Arbor, MI 48109-1005 (United States); Albrecht-Schmitt, Thomas E. [Department of Civil Engineering and Geological Sciences and Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556 (United States)

    2012-08-15

    Three Ba{sup 2+}/UO{sub 2}{sup 2+} methylenediphosphonates have been prepared from mild hydrothermal treatment of uranium trioxide, methylendiphosphonic acid (C1P2) with barium hydroxide octahydrate, barium iodate monohydrate, and small aliquots of HF at 200 Degree-Sign C. These compounds, Ba[UO{sub 2}[CH{sub 2}(PO{sub 3}){sub 2}]{center_dot}1.4H{sub 2}O (Ba-1), Ba{sub 3}[(UO{sub 2}){sub 4}(CH{sub 2}(PO{sub 3}){sub 2}){sub 2}F{sub 6}]{center_dot}6H{sub 2}O (Ba-2), and Ba{sub 2}[(UO{sub 2}){sub 2}(CH{sub 2}(PO{sub 3}){sub 2})F{sub 4}]{center_dot}5.75H{sub 2}O (Ba-3) all adopt layered structures based upon linear uranyl groups and disphosphonate molecules. Ba-2 and Ba-3 are similar in that they both have UO{sub 5}F{sub 2} pentagonal bipyramids that are bridged and chelated by the diphosphonate moiety into a two-dimensional zigzag anionic sheet (Ba-2) and a one-dimensional ribbon anionic chain (Ba-3). Ba-1, has a single crystallographically unique uranium metal center where the C1P2 ligand solely bridges to form [UO{sub 2}[CH{sub 2}(PO{sub 3}){sub 2}]{sup 2-} sheets. The interlayer space of the structures is occupied by Ba{sup 2+}, which, along with the fluoride ion, mediates the structure formed and maintains overall charge balance. - Graphical abstract: Illustration of the stacking of the layers in Ba{sub 3}[(UO{sub 2}){sub 4}(CH{sub 2}(PO{sub 3}){sub 2}){sub 2})F{sub 6}]{center_dot}6H{sub 2}O viewed along the c-axis. The structure is constructed from UO{sub 7} pentagonal bipyramidal units, U(1)O{sub 7}=gray, U(2)O{sub 7}=yellow, barium=blue, phosphorus=magenta, fluorine=green, oxygen=red, carbon=black, and hydrogen=light peach. Highlights: Black-Right-Pointing-Pointer The polymerization of the UO{sub 2}{sup 2+} sites to form uranyl dimers leads to structural variations in compounds. Black-Right-Pointing-Pointer Barium cations stitch uranyl diphosphonate anionic layers together, and help mediate structure formation. Black-Right-Pointing-Pointer HF acts as both a

  16. The effect of aspirated barium sulfate, iodixanol, and diatrizoic acid on survival and lung injury in a lagomorph model.

    Science.gov (United States)

    Siddiqui, M Tausif; Litts, Juliana K; Cheney, Diane M; Kuhn, Maggie A; Nativ-Zeltzer, Nogah; Belafsky, Peter C

    2017-05-01

    Contrast agents are an integral component of the video fluoroscopic swallow study. Agents commonly used include barium sulfate (E-Z Paque), iodixanol (Visipaque), and diatrizoic acid (Gastrografin). Barium is water insoluble, whereas iodixanol and diatrizoic acid are water-soluble iodine-based agents. The detrimental effect of these agents on the lungs has not been systematically evaluated. Our aim was to evaluate and compare the effects of aspirated barium, iodixanol, and diatrizoic acid on pulmonary injury in a lagomorph model. Animal model. Twenty adult male New Zealand White rabbits were divided into four groups (n = 5). Group 1 received 3 mL of barium sulfate injected into the trachea for 3 consecutive days. Group 2 received 3 mL of iodixanol injected into the trachea for 3 consecutive days. Group 3 received 3 mL of diatrizoic acid injected into the trachea for 3 consecutive days. A control group received 3 mL of air injected into the trachea under an identical protocol. All animals were euthanized on day 4, and the lung and trachea were harvested for blinded histopathologic analysis. The primary outcome measure was survival. The secondary endpoint was a blinded, histologic grading system of lung injury. Two animals in the barium group, one in the diatrizoic acid group, and 0 animals in the iodixanol and control groups died. The overall lung injury score for the barium (60.60 ± 6.34) and iodixanol groups (52.30 ± 3.11) were significantly higher (worse) than the diatrizoic acid (49.60 ± 7.64) and control groups (37.80 ± 3.56) (P barium sulfate (E-Z Paque) over 3 consecutive days causes more severe lung injury in a lagomorph model than 3 mL of aspirated iodixanol (Visipaque) and diatrizoic acid (Gastrografin). Diatrizoic acid caused the least histologic evidence of lung injury. NA Laryngoscope, 127:E148-E152, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Fabry-Perot measurements of barium temperature in fluorescent lamps

    International Nuclear Information System (INIS)

    Hadrath, S; Garner, R

    2010-01-01

    A scanning Fabry-Perot interferometer (FPI) is used to determine the temperature of barium atoms that are liberated from the electrodes of fluorescent lamps during their steady-state operation. Barium, a constituent of the work function lowering emitter material that is placed on the tungsten coil that forms the electrode, is liberated primarily by evaporation from the hot (∼1300 K) thermionic electrode. However, there may be situations or modes of operation in which barium is, in addition, sputtered, a condition which may lead to increased end-darkening, shortened life and increased mercury consumption in the lamp. Using the FPI diagnostic, the occurrence of sputtering is inferred when barium temperatures are much greater than the electrode temperature. The FPI diagnostic senses resonance radiation (λ = 553 nm) emitted by barium atoms excited in the low pressure discharge environment, and infers temperature from the Doppler broadened linewidth. The diagnostic has proven to be successful in a number of situations. Measurements have been made on rare gas discharges and on Hg-argon discharges for different discharge currents, gas pressures and auxiliary coil currents. Measurements are phase resolved for ac-driven discharges.

  18. Contrast media. Safety issues and ESUR guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, H.S. (ed.) [Copenhagen Univ. Hospital, Herlev (Denmark). Dept. of Diagnostic Radiology 54E2

    2006-07-01

    In 1994 the European Society of Urogenital Radiology (ESUR) set up a committee to consider the safety of the contrast media used in radiology departments. Since then, the committee has questioned members, reviewed the literature, proposed guidelines, and discussed these proposals with participants at the annual symposia on urogenital radiology. This book represents the end result of this hard work. It contains all of the agreed guidelines, updated when necessary, and thereby comprehensively covers the many different safety issues relating to the diverse contrast media: barium contrast media, iodinated contrast media, MR contrast media (both gadolinium-based extracellular and organ-specific) and ultrasound contrast media. The prevention and treatment of both acute and delayed non-renal adverse reactions as well as the renal adverse reactions are covered in detail. The inclusion of all the ESUR guidelines within one book will offer an invaluable, unique and unparalleled resource. (orig.)

  19. Contrast media. Safety issues and ESUR guidelines

    International Nuclear Information System (INIS)

    Thomsen, H.S.

    2006-01-01

    In 1994 the European Society of Urogenital Radiology (ESUR) set up a committee to consider the safety of the contrast media used in radiology departments. Since then, the committee has questioned members, reviewed the literature, proposed guidelines, and discussed these proposals with participants at the annual symposia on urogenital radiology. This book represents the end result of this hard work. It contains all of the agreed guidelines, updated when necessary, and thereby comprehensively covers the many different safety issues relating to the diverse contrast media: barium contrast media, iodinated contrast media, MR contrast media (both gadolinium-based extracellular and organ-specific) and ultrasound contrast media. The prevention and treatment of both acute and delayed non-renal adverse reactions as well as the renal adverse reactions are covered in detail. The inclusion of all the ESUR guidelines within one book will offer an invaluable, unique and unparalleled resource. (orig.)

  20. A randomized controlled trial of enemas in combination with oral laxative therapy for children with chronic constipation

    NARCIS (Netherlands)

    Bongers, Marloes E. J.; van den Berg, Maartje M.; Reitsma, Johannes B.; Voskuijl, Wieger P.; Benninga, Marc A.

    2009-01-01

    After 5 years of intensive oral laxative use, up to 30% of constipated children still have an unsuccessful outcome. Children refractory to oral laxatives might benefit from regular rectal evacuation by enemas. This randomized controlled trial compared the effects of additional treatment with rectal

  1. Simplified assessment of segmental gastrointestinal transit time with orally small amount of barium

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Weitang; Zhang, Zhiyong; Liu, Jinbo; Li, Zhen; Song, Junmin; Wu, Changcai [Department of Colorectal Surgery, The First Affiliated Hospital and Institute of Clinical Medicine, Zhengzhou University, 450052 Zhengzhou (China); Wang, Guixian, E-mail: guixianwang@hotmail.com [Department of Colorectal Surgery, The First Affiliated Hospital and Institute of Clinical Medicine, Zhengzhou University, 450052 Zhengzhou (China)

    2012-09-15

    Objective: To determine the effectiveness and advantage of small amount of barium in the measurement of gastrointestinal transmission function in comparison with radio-opaque pallets. Methods: Protocal 1: 8 healthy volunteers (male 6, female 2) with average age 40 ± 6.1 were subjected to the examination of radio-opaque pellets and small amount of barium with the interval of 1 week. Protocol 2: 30 healthy volunteers in group 1 (male 8, female 22) with average age 42.5 ± 8.1 and 50 patients with chronic functional constipation in group 2 (male 11, female 39) with average age 45.7 ± 7.8 were subjected to the small amount of barium examination. The small amount of barium was made by 30 g barium dissolved in 200 ml breakfast. After taking breakfast which contains barium, objectives were followed with abdominal X-ray at 4, 8, 12, 24, 48, 72, 96 h until the barium was evacuated totally. Results: Small amount of barium presented actual chyme or stool transit. The transit time of radio-opaque pallets through the whole gastrointestinal tract was significantly shorter than that of barium (37 ± 8 h vs. 47 ± 10 h, P < 0.05) in healthy people. The transit times of barium in constipation patients were markedly prolonged in colon (61.1 ± 22 vs. 37.3 ± 11, P < 0.01) and rectum (10.8 ± 3.7 vs. 2.3 ± 0.8 h, P < 0.01) compared with unconstipated volunteers. Transit times in individual gastrointestinal segments were also recorded by using small amount of barium, which allowed identifying the subtypes of constipation. Conclusion: The small amount barium examination is a convenient and low cost method to provide the most useful and reliable information on the transmission function of different gastrointestinal segments and able to classify the subtypes of slow transit constipation.

  2. Simplified assessment of segmental gastrointestinal transit time with orally small amount of barium

    International Nuclear Information System (INIS)

    Yuan, Weitang; Zhang, Zhiyong; Liu, Jinbo; Li, Zhen; Song, Junmin; Wu, Changcai; Wang, Guixian

    2012-01-01

    Objective: To determine the effectiveness and advantage of small amount of barium in the measurement of gastrointestinal transmission function in comparison with radio-opaque pallets. Methods: Protocal 1: 8 healthy volunteers (male 6, female 2) with average age 40 ± 6.1 were subjected to the examination of radio-opaque pellets and small amount of barium with the interval of 1 week. Protocol 2: 30 healthy volunteers in group 1 (male 8, female 22) with average age 42.5 ± 8.1 and 50 patients with chronic functional constipation in group 2 (male 11, female 39) with average age 45.7 ± 7.8 were subjected to the small amount of barium examination. The small amount of barium was made by 30 g barium dissolved in 200 ml breakfast. After taking breakfast which contains barium, objectives were followed with abdominal X-ray at 4, 8, 12, 24, 48, 72, 96 h until the barium was evacuated totally. Results: Small amount of barium presented actual chyme or stool transit. The transit time of radio-opaque pallets through the whole gastrointestinal tract was significantly shorter than that of barium (37 ± 8 h vs. 47 ± 10 h, P < 0.05) in healthy people. The transit times of barium in constipation patients were markedly prolonged in colon (61.1 ± 22 vs. 37.3 ± 11, P < 0.01) and rectum (10.8 ± 3.7 vs. 2.3 ± 0.8 h, P < 0.01) compared with unconstipated volunteers. Transit times in individual gastrointestinal segments were also recorded by using small amount of barium, which allowed identifying the subtypes of constipation. Conclusion: The small amount barium examination is a convenient and low cost method to provide the most useful and reliable information on the transmission function of different gastrointestinal segments and able to classify the subtypes of slow transit constipation

  3. Effects of detomidine on equine oesophageal function as studied by contrast radiography

    International Nuclear Information System (INIS)

    Watson, T.D.G.; Sullivan, M.

    1991-01-01

    The effects of sedation with detomidine on oesophageal function were assessed by contrast radiography in 10 healthy adult thoroughbred horses. Barium swallows were monitored by means of image intensification, first without sedation and then after the intravenous administration of detomidine at doses of 10 and 20 micrograms/kg bodyweight. The transit time of contrast agent to the oesophageal hiatus was recorded and each swallow was scored for markers of oesophageal dysfunction. Analysis of the data indicated that there were highly significant dose dependent increases in the transit time, the retention of barium within the longitudinal mucosal folds, and retrograde peristalsis and pooling of contrast agent within the oesophagus at both the thoracic inlet and caudal to the base of the heart. The degree of gastrooesophageal reflux was not affected at either dosage. These changes in oesophageal function were similar to those recorded from cases of grass sickness and indicate that care should be taken in the interpretation of studies of swallowing in animals that have been given detomidine before a radiographic examination

  4. Easier to swallow: pictorial review of structural findings of the pharynx at barium pharyngography.

    Science.gov (United States)

    Tao, Ting Y; Menias, Christine O; Herman, Thomas E; McAlister, William H; Balfe, Dennis M

    2013-01-01

    Barium pharyngography remains an important diagnostic tool in the evaluation of patients with dysphagia. Pharyngography can not only help detect functional abnormalities but also help identify a wide spectrum of structural abnormalities in children and adults. These structural abnormalities may reflect malignant or nonmalignant oropharyngeal, hypopharyngeal, or laryngeal processes that deform or alter normal coated mucosal surfaces. Therefore, an understanding of the normal appearance of the pharynx at contrast material-enhanced imaging is necessary for accurate detection and interpretation of abnormal findings. Congenital malformations are more typically identified in the younger population; inflammatory and infiltrative diseases, trauma, foreign bodies, and laryngeal cysts can be seen in all age groups; and Zenker and Killian-Jamieson diverticula tend to occur in the older population. Squamous cell carcinoma is by far the most common malignant process, with contrast-enhanced imaging findings that depend on tumor location and morphology. Treatments of head and neck cancers include total laryngectomy and radiation therapy, both of which alter normal anatomy. Patients are usually evaluated immediately after laryngectomy to detect complications such as fistulas; later, pharyngography is useful for identifying and characterizing strictures. Deviation from the expected posttreatment appearance, such as irregular narrowing or mucosal nodularity, should prompt direct visualization to evaluate for recurrence. Contrast-enhanced imaging of the pharynx is commonly used in patients who present with dysphagia, and radiologists should be familiar with the barium pharyngographic appearance of the normal pharyngeal anatomy and of some of the processes that alter normal anatomy. © RSNA, 2013.

  5. Barium ion beam. Annual progress report

    International Nuclear Information System (INIS)

    Lazar, N.; Dandl, R.; Rynn, N.; Wickham, M.

    1985-01-01

    The barium ion beam Zeeman diagnostic is an in situ nonperturbing diagnostic designed to measure both the plasma electric and magnetic fields in devices such as STM and EBT. The diagnostic satisfies the requirements of high precision, spatial resolution and nonperturbation of the plasma. The technique uses resonance absorption of light from a single moded laser in a beam of energetic barium ions to measure the Zeeman effect in the absorption spectrum (to measure changes in the magnetic field) and to observe the changes in beam velocity by the Doppler shift of the absorption lines

  6. Longitudinal changes in extended roles in radiography

    International Nuclear Information System (INIS)

    Price, R.C.; Miller, L.R.; Mellor, F.

    2002-01-01

    Purpose: The purpose of this research was to identify the extent and scope of changes to radiography practice. Method: Questionnaires were sent to radiology managers at acute National Health Service (NHS) hospitals in 2000 as a follow-up to an initial survey conducted in 1998. Information was sought on region, teaching/non-teaching status, the nature of extended role tasks undertaken and the year in which these tasks were first undertaken. Results: Some 172 questionnaires were returned from a total of 253 dispatched (68%). In 161 hospitals radiographers administered intravenous injections and performed barium enemas in 119 hospitals, while a red-dot system was in operation in 141 hospitals. Reporting by radiographers had increased since 1998. Replies indicated that, at 124 hospitals, radiographers were reporting in ultrasound. Skeletal reporting was the second most-frequently-reported activity, with 63 hospitals indicating that radiographers reported in this modality, while barium enemas were reported by radiographers in 34 hospitals. Reporting was also undertaken by radiographers in mammography, nuclear medicine, paediatrics and chest radiography in a small minority of hospitals. There was no statistically significant difference between the adoption of tasks in non-teaching and teaching hospitals with the exception of radiographer-performed barium enemas (P=0.014) and red-dot systems (P=0.05). Radiographers were more likely to undertake both of these activities at non-teaching hospitals than in teaching hospitals. Regional differences were apparent in reporting, with a greater prevalence in the English regions than Northern Ireland, Scotland and Wales. Conclusion: The study provided data that demonstrated the extent to which hospitals are utilizing the developing skills of radiographers. This has important implications for future education and training needs for radiographers and for delivery of imaging services

  7. Radiologic evaluation of colorectal cancer

    International Nuclear Information System (INIS)

    Lee, Young Joong; Kang, Hee Tae; Kim, Jong Deok; Rhee, Hak Song

    1984-01-01

    The incidence of colorectal cancer of Korea is much lower than that of Western countries, but has shown a tendency to a slight increase recently. Barium enema is the most valuable, noninvasive and inexpensive method available to evaluate the size, shape and site of colorectal cancer. The authors reviewed and radiologically classified barium enema studies of 232 cases of colorectal cancer from Aug. 1967 to July 1982 at Presbyterian Medical Center, Jeonju, Confirmed clinically, operatively and pathologically. The results were as follows; 1. The ratio of male and female was 1.3:1, and youngest was 13 year-old and the oldest 86 year-old. 2. The peak incidence occurred from 5th to 7th decades, accounting for 78% of all cases (181/232), and there was a relatively high incidence of the disease in patients below 30 years of age at 7.8% (18/232). 3. Rectum and rectosigmoid region are the most frequently involved regions (127/232:54.8%). 4. The positivity of barium enema examination was 4.0% (232/5807), and its accuracy was 96.5% (224/232). 5. The radiologic findings were classified into 4 groups, and they were annular encircling 62.9% (146/232). polypoid fungating 26.8% (62/232), infiltrating 8.6% (20/232), and primary ulcerating 1.7% (4/232) in order of frequency. 6. The linear length of the cancer ranged from 1.5 Cm to 15 Cm, and the average length was 5.5 Cm. 7. There was no statistical correlation between the length of lesion, the site, and the radiologic findings, and stages of the lesion (P:0.750-0.250). 8. The majority of colorectal cancers was adenocarcinoma (217/232:93.6%)

  8. Characterization of Barium Borate Frameworks Using Raman Spectroscopy.

    Science.gov (United States)

    Gharavi-Naeini, Jafar; Yoo, Kyung W; Stump, Nathan A

    2018-04-01

    Systematic micro-Raman scattering investigations have been carried out on Sm +2 doped 2(BaO)-n(B 2 O 3 ) matrices for n = 4, 5, 8, and 2(BaO)-(Na 2 O)-9(B 2 O 3 ) using the 364 nm excitation of an Ar + laser. The Raman results have been compared with the known structures of barium tetraborate, barium pentaborate, barium octaborate, and barium sodium nonaborate. An excellent correlation has been found between the BO 4 /BO 3 composition ratios for each product and intensity ratios of the designated BO 4 and BO 3 Raman peaks. Furthermore, the Raman frequencies of both BO 4 and BO 3 groups undergo a systematic blueshift as n increases from four to nine. The shift results from a decrease of the B-O bond lengths for both BO 4 and BO 3 groups as the samples transition from the tetraborate to nonaborate structures. Linear relations (with negative slopes) have been determined between the measured Raman frequencies and B-O bond lengths in the frameworks.

  9. 40 CFR 721.10010 - Barium manganese oxide (BaMnO3).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Barium manganese oxide (BaMnO3). 721... Substances § 721.10010 Barium manganese oxide (BaMnO3). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium manganese oxide (BaMnO3) (PMN P-00...

  10. Computed tomography of intussusception in adult

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Ahn, Byeong Yeob; Cha, Soon Joo; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuck

    1984-01-01

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  11. Two cases of colorectal cancer complicating radiation enterocolitis

    International Nuclear Information System (INIS)

    Honma, Kaneatsu; Muto, Yoshihiro; Kusano, Toshiomi; Tokumine, Akio; Okushima, Norihiko; Tamashiro, Tetsuo

    1993-01-01

    A 74-year-old woman presented with bowel movement disorder. She had received radiation therapy with 60 Gy for uterine cervical cancer approximately 20 years before. Barium enema and colonofiberscopy revealed radiation enterocolitis. Thereafter, the patient was admitted to the hospital due to stricture of the sigmoid colon and an increased CEA and was diagnosed as having Borrmann II type colorectal well differentiated adenocarcinoma. Histological examination revealed stage I with no associated lymph node metastases. She is alive 3 years and 10 month after surgery. The other patient was a 65 year-old woman with a history of cervical cancer. Twenty-one years after combined hysterectomy and postoperative external irradiation of 45 Gy, the patient presented with melena. Detailed examination revealed colorectal adenocarcinoma. Simultaneously, barium enema revealed radiation enterocolitis. At surgery, intrapelvic area was found to be frozen due to irradiation. She has no evidence of metastasis 2 years after surgery. As can be shown in the two patients, patients developing radiation enterocolitis should be followed up periodically for the early detection of coexistent colorectal cancer. (N.K.)

  12. Postoperative MR evaluation of the neorectum in patients with congenital anorectal malformations

    International Nuclear Information System (INIS)

    Hedlund, G.L.; Bisset, G.S.

    1989-01-01

    Five patients with an original diagnosis of supralevator anal atresia had fecal incontinence following pull-through procedures. The imaging evaluation initially included barium enema and MR studies. Perineal electrostimulation data were also obtained. MR imaging was performed with a 1.5-T system. A tuberculin syringe filled with chloral hydrate was inserted into the neorectum to serve as a high-signal-intensity lumen marker. T1-weighted images were obtained in the sagittal, coronal, and axial planes with a spin-echo pulse sequence 60/20 (repetition time msec). The neorectum was determined to be centrally positioned or eccentrically placed within the external anal sphincter and puborectalis muscles. Prospectively, MR imaging accurately indicated the position of the neorectum relative to the sphincteric muscular complex. Perineal electrostimulation data were concordant with MR findings in all patients. Barium enema was helpful in one patient with rectal stricture at the pull-through site. The authors discuss how MR imaging of the postoperative neorectum in patients with fecal incontinence provides useful information in planning the surgical revision

  13. Three-dimensional-CT imaging of colorectal disease with thin collimation helical CT scanning

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Koizumi, Koichi; Sakai, Tatsuya; Kai, Shunkichi; Takatsu, Kazuaki; Maruyama, Masakazu

    1998-01-01

    We have conducted research on three-dimensional (3D)-CT-colonoscopy with thin collimation helical CT scanning over the past three years. This has lately become a subject of special interest. 3D-CT-colonoscopy has three kinds of visualizing methods depending on the threshold setting of CT values. The first one is the virtual endoscopy method which is displayed in a similar fashion to colonoscopic images. The second one is the air image method using the air in the digestive tract as a contrast medium. The third one is the pseudo-tract method which has characteristics of both virtual endoscopy and the air image method and visualizes in a shape of the digestive tract. The image visualized by 3D-CT-colonoscopy is similar to that of conventional colonoscopy and barium enema study, which is obtained with minimal invasion to patients. Obvious advanced carcinomas were easily visualized, and even a small flat polyp measuring 5 mm in size, was able to be observed retrospectively. The characteristics of our method are that we can easily make an examination in a short time and with little dependence on expert technique. Also patients have little discomfort compared to that experienced during colonoscopy and barium enema study. Important features are as follows; long calculation time, insufficient air insufflation, fecal material in the patient''s bowel, whole abdominal scan, and spatial resolution. In the near future, a multislice CT scanner system will have ability to overcome these problems. Therefore, 3D-CT-colonoscopy might be applied in the future for first line examination as a mass screening for colorectal carcinoma. (author)

  14. Radiation losses in microwave K{sub u} region by conducting pyrrole/barium titanate and barium hexaferrite based nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Talwinder [Department of Physics, Lovely Professional University, Phagwara 144411 (India); Kumar, Sachin [Department of Chemistry, Guru Nanak Dev University, Amritsar 143005 (India); Narang, S.B. [Department of Electronics Technology, Guru Nanak Dev University, Amritsar 143005 (India); Srivastava, A.K., E-mail: srivastava_phy@yahoo.co.in [Department of Physics, Lovely Professional University, Phagwara 144411 (India)

    2016-12-15

    Nanocomposites of substituted barium hexaferrite and barium titanate embedded in a polymer were synthesized via emulsion polymerization. The study was performed by using X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy, electron spin resonance spectroscopy, a vibrating sample magnetometer and a vector network analyzer. It is found that maximum radiation loss occur at 16.09 GHz (−14.23 dB) frequency owing to the combined effect of conducting polymer, suitable dielectric and magnetic material. This suggests that prepared material is suitable for radiation losses. Micro structural study reveals the presence of all the phases of the compounds comprises composite. Benzene ring absorption band (at 1183 cm{sup −1}) in FT-IR spectra illustrates the presence of polymer. Surface morphology reveals the presence of array of particles encapsulated by the polymer. - Highlights: • Composites having polymer, barium titanate and hexaferrite have been successfully prepared. • Effective radiation absorption and losses have been achieved. • Magnetic properties have made an impact on shielding effectiveness.

  15. Radium-226 and barium as tracers of water masses in the North Atlantic (GA01-GEOTRACES)

    Science.gov (United States)

    Le Roy, Emilie; Sanial, Virginie; Charette, Matthew; Henderson, Paul; Jacquet, Stéphanie; García-Ibáñez, Maribel; Pérez, Fiz; Lherminer, Pascale; Souhaut, Marc; Jeandel, Catherine; Lacan, François; van Beek, Pieter

    2017-04-01

    In this study, we report concentrations of radium-226 (226Ra, t1/2=1602 y) and barium determined along the GEOVIDE section conducted in the North Atlantic (May-July 2014; Portugal-Greenland-Canda) in the framework of the international GEOTRACES program. A high vertical resolution (up to 22 depths per station) was achieved by analyzing small volumes (˜10 L) of seawater for 226Ra using a radon emanation technique. We will present the distribution of 226Ra activities and barium concentrations in contrasting biogeochemical regions of the North Atlantic (Iberian margin, West European Basin, Reykjanes Ridge, Irminger Sea, Greenland margin and Labrador Sea). These regions strongly differ in terms of boundary inputs, biogeochemistry and deep water formation. We observe a linear correlation between 226Ra and barium along the GEOVIDE section, which results from the dominantly conservative behavior of the two tracers. However, deviations from the linear correlation between 226Ra and Ba are found in several places. The potential causes for such deviations are investigated. Optimum multi-parameter (OMP) analysis was thus used to distinguish the relative importance of physical transport (i.e., water mass mixing) from non-conservative processes (sedimentary, river or hydrothermal inputs; uptake by particles) on the 226Ra and Ba distribution in the North Atlantic.

  16. Preparation of porous nano barium ferrite and its adsorption properties on uranium

    International Nuclear Information System (INIS)

    Xiong Guoxuan; Huang Haiqing; Zhang Zhibin

    2012-01-01

    The porous nano barium ferrite was made of Fe(NO 3 ) 3 and Ba(NO 3 ) 2 as raw materials, CTAB as surfactant by method of sol-gel and self-propagating combustion. The composition, morphology and magnetic properties of nano-rod barium ferrite were characterized by XRD, SEM and vibrating sample magnetometer. The adsorption properties of porous nano barium ferrite on uranium were studied with static adsorption and the effects of pH, adsorption temperature and oscillation time on adsorption properties were discussed. The results indicate that the average particle size of porous nano barium ferrite is 45-65 nm, the saturation magnetization and coercivity are 62.83 emu/g and 5481.0 Oe, respectively. Under the condition of the porous nano barium ferrite amount of 0.02 g, pH of 6, adsorption temperature of 25℃ and oscillation time of 30 min, the adsorption capacity of uranium on the porous nano barium ferrite reaches 921 μg/g. (authors)

  17. A review of the health impacts of barium from natural and anthropogenic exposure.

    Science.gov (United States)

    Kravchenko, Julia; Darrah, Thomas H; Miller, Richard K; Lyerly, H Kim; Vengosh, Avner

    2014-08-01

    There is an increasing public awareness of the relatively new and expanded industrial barium uses which are potential sources of human exposure (e.g., a shale gas development that causes an increased awareness of environmental exposures to barium). However, absorption of barium in exposed humans and a full spectrum of its health effects, especially among chronically exposed to moderate and low doses of barium populations, remain unclear. We suggest a systematic literature review (from 1875 to 2014) on environmental distribution of barium, its bioaccumulation, and potential and proven health impacts (in animal models and humans) to provide the information that can be used for optimization of future experimental and epidemiological studies and developing of mitigative and preventive strategies to minimize negative health effects in exposed populations. The potential health effects of barium exposure are largely based on animal studies, while epidemiological data for humans, specifically for chronic low-level exposures, are sparse. The reported health effects include cardiovascular and kidney diseases, metabolic, neurological, and mental disorders. Age, race, dietary patterns, behavioral risks (e.g., smoking), use of medications (those that interfere with absorbed barium in human organism), and specific physiological status (e.g., pregnancy) can modify barium effects on human health. Identifying, evaluating, and predicting the health effects of chronic low-level and moderate-level barium exposures in humans is challenging: Future research is needed to develop an understanding of barium bioaccumulation in order to mitigate its potential health impacts in various exposured populations. Further, while occupationally exposed at-risk populations exist, it is also important to identify potentially vulnerable subgroups among non-occupationally exposed populations (e.g., elderly, pregnant women, children) who are at higher risk of barium exposure from drinking water and food.

  18. The diagnosis of gastro-esophageal reflux disease cannot be made with barium esophagograms.

    Science.gov (United States)

    Saleh, C M G; Smout, A J P M; Bredenoord, A J

    2015-02-01

    For over 50 years, barium studies have been used to diagnose gastro-esophageal reflux disease (GERD), but the value of this test is controversial. Our study aimed to determine if barium esophagograms can be used to diagnose GERD. Barium esophagograms and pH-impedance measurement were performed in 20 subjects with reflux symptoms. pH-impedance measurements were used as gold standard for the diagnosis of GERD. Gastro-esophageal reflux measured with the barium study was defined as a positive outcome. 50% of patients presented gastro-esophageal reflux on the barium esophagogram. No significant differences were observed in acid exposure time between subjects with (median: 7.4%; interquartile range, IQR: 8.4%) or without reflux at barium esophagography (median: 5.95%; IQR: 13.05%; p > 0.05). Nor did we find differences in median proximal extent of reflux measured with impedance monitoring between patients with a positive (median: 6.7%; IQR: 1.95%) and negative barium study (median: 7.1%; IQR: 0.68%; p > 0.05). Patients with reflux on barium esophagogram did not have a positive symptom association probability more often than those who did not have reflux at barium esophagography. Lastly, there were no differences in numbers of acid, weakly acidic or total reflux episodes between those with positive or negative barium esophagogram (p > 0.05). No correlations were found between the maximum proximal extent of gastro-esophageal reflux during esophagography and pH-impedance parameters. Presence or absence of gastro-esophageal reflux during barium esophagography does not correlate with incidence or extent of reflux observed during 24-h pH-impedance monitoring and is not of value for the diagnosis of GERD. © 2014 John Wiley & Sons Ltd.

  19. Is knowing believing? The role of event plausibility and background knowledge in planting false beliefs about the personal past.

    Science.gov (United States)

    Pezdek, Kathy; Blandon-Gitlin, Iris; Lam, Shirley; Hart, Rhiannon Ellis; Schooler, Jonathan W

    2006-12-01

    False memories are more likely to be planted for plausible than for implausible events, but does just knowing about an implausible event make individuals more likely to think that the event happened to them? Two experiments assessed the independent contributions o f plausibility a nd background knowledge to planting false beliefs. In Experiment 1, subjects rated 20 childhood events as to the likelihood of each event having happened to them. The list included the implausible target event "received an enema," a critical target event of Pezdek, Finger, and Hodge (1997). Two weeks later, subjects were presented with (1) information regarding the high prevalence rate of enemas; (2) background information on how to administer an enema; (3) neither type of information; or (4) both. Immediately or 2 weeks later, they rated the 20 childhood events again. Only plausibility significantly increased occurrence ratings. In Experiment 2, the target event was changed from "barium enema administered in a hospital" to "home enema for constipation"; significant effects of both plausibility and background knowledge resulted. The results suggest that providing background knowledge can increase beliefs about personal events, but that its impact is limited by the extent of the individual's familiarity with the context of the suggested target event.

  20. [Iatrogen perforation of the rectum after colon radiography].

    Science.gov (United States)

    Eggum, R; Kressner, U; Haffner, J

    1998-05-10

    Perforation of the rectum following barium enema is relatively rare, occurring in 1 of 3,000 procedures. Colorectal perforation is a serious condition and early diagnosis is of paramount importance in order to avoid any delay in treating the patient. Direct suture of the perforation, lavage, presacral drainage and stomia are the preferred methods of primary surgical treatment.

  1. Colonic polyps: inheritance, susceptibility, risk evaluation, and diagnostic management

    Directory of Open Access Journals (Sweden)

    Emanuele Neri

    2010-12-01

    Full Text Available Emanuele Neri, Lorenzo Faggioni, Lorenzo Cini, Carlo BartolozziDiagnostic and Interventional Radiology, University of Pisa, Pisa, ItalyAbstract: Colorectal cancer (CRC is the third-ranked neoplasm in order of incidence and mortality, worldwide, and the second cause of cancer death in industrialized countries. One of the most important environmental risk factors for CRC is a Western-type diet, which is characterized by a low-fiber and high-fat content. Up to 25% of patients with CRC have a family history for CRC, and a fraction of these patients are affected by hereditary syndromes, such as familial adenomatous polyposis, Gardner or Turcot syndromes, or hereditary nonpolyposis colorectal cancer. The onset of CRC is triggered by a well-defined combination of genetic alterations, which form the bases of the adenoma-carcinoma sequence hypothesis and justify the set-up of CRC screening techniques. Several screening and diagnostic tests for CRC are illustrated, including rectosigmoidoscopy, optical colonoscopy (OC, double contrast barium enema (DCBE, and computed tomography colonography (CTC. The strengths and weaknesses of each technique are discussed. Particular attention is paid to CTC, which has evolved from an experimental technique to an accurate and mature diagnostic approach, and gained wide acceptance and clinical validation for CRC screening. This success of CTC is due mainly to its ability to provide cross-sectional analytical images of the entire colon and secondarily detect extracolonic findings, with minimal invasiveness and lower cost than OC, and with greater detail and diagnostic accuracy than DCBE. Moreover, especially with the advent and widespread availability of modern multidetector CT scanners, excellent quality 2D and 3D reconstructions of the large bowel can be obtained routinely with a relatively low radiation dose. Computer-aided detection systems have also been developed to assist radiologists in reading CTC examinations

  2. Selective blockade of leukotriene production by a single dose of the FPL 64170XX 0.5% enema in active ulcerative colitis

    DEFF Research Database (Denmark)

    Kjeldsen, J; Laursen, L S; Hillingsø, Jens

    1995-01-01

    5-Lipoxygenase products of arachidonic acid metabolism are thought to play a central role in the secondary amplification of the inflammatory response of several inflammatory diseases, including ulcerative colitis. FPL 64170XX is a selective inhibitor of the enzyme 5-lipoxygenase. Concentrations...... containing 0.5% of FPL 64170XX. Repeated measures analysis of leukotriene B4, after adjusting for baseline, showed a significant treatment effect (P = 0.0014). The concentration of leukotriene B4 from rectal dialysates in patients receiving the active drug dropped to 15% (95% confidence interval 5......-40%) of the placebo level in the second dialysis following administration of FPL 64170XX 0.5%. By contrast, prostaglanding E2 concentrations doubled (P = 0.0068) in patients receiving FPL 64170XX 0.5% with no change in the placebo group. These findings demonstrate that a single dose of FPL 64170XX 0.5% enema...

  3. Application of magnesium hydroxide and barium hydroxide for the ...

    African Journals Online (AJOL)

    Application of magnesium hydroxide and barium hydroxide for the removal of metals and sulphate from mine water. ... equivalent to the Ba(OH)2 dosage. During CO2-dosing, CaCO3 is precipitated to the saturation level of CaCO3. Keywords: Magnesium hydroxide; barium hydroxide; sulphate removal; water treatment ...

  4. 49 CFR 173.182 - Barium azide-50 percent or more water wet.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Barium azide-50 percent or more water wet. 173.182 Section 173.182 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... Class 1 and Class 7 § 173.182 Barium azide—50 percent or more water wet. Barium azide—50 percent or more...

  5. Barium-borate-flyash glasses: As radiation shielding materials

    International Nuclear Information System (INIS)

    Singh, Sukhpal; Kumar, Ashok; Singh, Devinder; Thind, Kulwant Singh; Mudahar, Gurmel S.

    2008-01-01

    The attenuation coefficients of barium-borate-flyash glasses have been measured for γ-ray photon energies of 356, 662, 1173 and 1332 keV using narrow beam transmission geometry. The photon beam was highly collimated and overall scatter acceptance angle was less than 3 o . Our results have an uncertainty of less than 3%. These coefficients were then used to obtain the values of mean free path (mfp), effective atomic number and electron density. Good agreements have been observed between experimental and theoretical values of these parameters. From the studies of the obtained results it is reported here that from the shielding point of view the barium-borate-flyash glasses are better shields to γ-radiations in comparison to the standard radiation shielding concretes and also to the ordinary barium-borate glasses

  6. Charge distributions of barium isotopes from muonic X-rays

    International Nuclear Information System (INIS)

    Shera, E.B.; Wohlfahrt, H.D.; Hoehn, M.V.; Tanaka, Y.

    1982-01-01

    The results of a muonic X-ray study of the charge radii of stable barium isotopes are presented and compared with optical isotope shifts. The isotope shifts Δ 2 > of a wide range of barium isotopes are found to be in good agreement with the droplet model and with IBA calculations. (orig.)

  7. HIRSCHSPRUNG'S DISEASE—The Clinical Differentiation and Treatment of Children with Hirschsprung's Disease and Pseudo-Hirschsprung's Disease

    Science.gov (United States)

    Ravitch, Mark M.

    1958-01-01

    Hirschsprung's disease is marked by constipation from the time of birth, with the development, if uncorrected, of a protuberant abdomen and flared costal margins. The rectal ampulla is empty and the abdomen is filled with fecal masses. Pain is not prominent. Flatus is passed in large amounts. Encopresis does not occur. Barium enema shows the characteristic narrowed distal rectal segment and biopsy of the rectum shows absence of the ganglion cells of the myenteric plexus. Treatment is operative resection of the distal narrow segment and a primary anastomosis. Hirschsprung's disease may be mimicked in children with: 1. Psychogenic constipation—pseudo-Hirschsprung's disease. Unlike Hirschsprung's disease, symptoms do not appear at birth, encopresis is common, and the barium enema shows no narrow distal segment. 2. Mental retardation and cerebral defect. 3. Corrected imperforate anus—on the basis of stenosis, imperfect innervation or poor habit training. 4. Cretinism—with severe constipation and intestinal dilatation perhaps the presenting symptoms. Treatment of these four groups of children with severe constipation not due to Hirschsprung's disease is: For Group 1, open discussion with parent and child. Assumption by the physician of full control of the details of treatment, and relegation of parent to the role of the physician's agent in following the prescribed regimen. For Group 2, an enema regimen. Whereas fairly rapid restoration (and then persistence) of normal bowel habit can be expected in Group 1, the basic defects in Group 2 may require indefinite continuation of treatment. For Group 3, regular enema regimen, in the less severe cases—one identical with that used in Group 1, and dilatation of strictures or anoplasty. In Group 4, thyroid hormone therapy relieves the constipation of hypothyroidism and causes reversion of radiographic changes in the colon and rectum. PMID:13561108

  8. Chronic appendicitis and complete appendiceal invagination: UC, CT and MRI findings

    International Nuclear Information System (INIS)

    Diaz, Gabriel; Seehaus, Alberto; Ocantos, Jorge; Diaz, Claudia; Coccaro, Nicolas; Piccioni, Hector

    2003-01-01

    The appendiceal intussusception is a rare entity. Usually there is a predisposing factor such as a tumor, mucocele, etc. We report the case of a 61 years old female patient, with recurrent abdominal pain, localized in the right lower quadrant. We performed different diagnostic imaging exams including: double-contrast barium enema, enteroclysis, ultrasonography, computed tomography and magnetic resonance. After endoscopy a surgical procedure removed the appendix. The pathological anatomy confirmed the diagnosis of an appendiceal intussusception, complicated with a chronic inflammatory process. Appendiceal intussusception and chronic appendicitis are infrequent; it is even more uncommon the association of both entities. In addition, it was not found a predisposing cause to intussusception. For the reasons described above, we conclude that this case is an unusual presentation of appendiceal intussusception, not previously reported. (author)

  9. Assessment of the efficacy of the education of radiographers who interpret CT-colonography examinations

    DEFF Research Database (Denmark)

    Lauridsen, Carsten Ammitzbøl; Jeppesen, Lau; Westphal, Lena

    2014-01-01

    could increase the interpretation time and create significant logistical challenges in busy diagnostic imaging departments. The shortage of radiologists makes this an impractical long‐term solution; therefore diagnostic imaging departments should ensure efficient work routines and assess...... diagnostic modalities are used for colonic evaluation including rectoscopy, flexible sigmoideoscopy, OC, fecal occult blood test, double contrast barium enema, magnetic resonance colonography and CTC. However, OC is considered to be the gold standard due to a high diagnostic accuracy and the option......‐center trial reported excellent sensitivity for large adenomas and cancers.17 A further study by Kim et al., compared the diagnostic yield from parallel OC and CTC screening programs and found similar detection rates of advanced neoplasia in the two groups.18 Some studies have documented wide inter...

  10. Making of Magnet Barium Ferit Anisotropic

    International Nuclear Information System (INIS)

    Idayati, Novrita; Dedi

    2003-01-01

    Barium Hexa ferrite (BaFe 12 O 19 ) is ceramic and materials which usually used for making of permanent magnet. In this research Barium Hexa ferrite were made Anisotropic, and applied for loudspeaker, electro motors, dynamo, KWh metre, etc. this Magnet is commonly used due to its high Induction of Remanen (Br) and coercivity (high Hc). Besides it applies a more simple and easier process technology, cheaper raw material, and easy to find it, hence the magnetic component is much cheaper. Powder Metallurgy was used for the process technology, by reacting all materials in the powder (oxide), with a certain size distribution and a tight preparation step. The next step was mixing ferrite and Barium Carbonate (in the form of oxide), calcination, compaction, cantering and characterisation. The Anisotropic particle effects a high Induce Remanen (Br) and of koersifitas (high Hc). All the process steps will is determine physical and chemical characteristics of the magnet. The best Magnet characteristic of the magnet produced in this research is Induction of Remanen (Br) = 4,27 kg, Coercivity (Hc) = 1,745 kOe, Energy Product max (BHmaks) = 2,31 MGOe

  11. Evaluation of the application of enemas containing sucralfate in tissue content of neutral and acid mucins in experimental model of diversion colitis.

    Science.gov (United States)

    Chaim, Felipe Mendonça; Sato, Daniela Tiemi; Rodrigues, Murilo Rocha; Dias, Alice Moreira; Silveira Júnior, Paulo Pedroso; Pereira, José Aires; Martinez, Carlos Augusto Real

    2014-09-01

    To evaluate the effects of sucralfate on tissue content of neutral and acids mucins in rats with diversion colitis. Thirty-six rats were submitted to a proximal right colostomy and a distal mucous fistula. They were divided into two groups according to sacrifice to be performed two or four weeks after intervention. Each group was divided into three subgroups according daily application of enemas containing saline, sucralfate at 1.0 g/kg/day or 2.0 g/kg/day. Colitis was diagnosed by histological analysis and neutral and acid mucins by Periodic Acid Schiff and Alcian Blue techniques, respectively. The contents of mucins were quantified by computer-assisted image analysis. Student's t paired and ANOVA test were used to compare the contents of both types of mucins among groups, and to verify the variance with time, establishing level of signification of 5% for both (p<0.05). Enemas containing sucralfate improves the inflammation and increases the tissue contents of neutral and acid mucins. The content of neutral mucins does not change with the time or concentration of sucralfate used, while acid mucins increases with concentration and time of intervention. Sucralfate enemas improve the inflammatory process and increase the tissue content of neutral and acid mucins in colon without fecal stream.

  12. Thermal reactions of some calcium, strontium, and barium chromates

    International Nuclear Information System (INIS)

    Piekarska-Piesse, B.; Gontarz, Z.; Ostrowski, A.; Kucharski, R.

    2000-01-01

    Thermal decomposition of calcium chromates and solid state reactions of barium and strontium chromates(VI) with barium and strontium hydroxides and carbonates, as well as the reduction of chromates by carbon and hydrogen, have been investigated. The mechanisms of individual stages of the thermal decomposition have been proposed on the basis of morphological classification. (author)

  13. Radiological diagnostics of the early gastric carcinoma by means of the double-contrast technique

    Energy Technology Data Exchange (ETDEWEB)

    Faust, H

    1981-05-01

    Radiological efforts to detect early gastric cancer have been intensified by three facts: 1) the prognostic importance, 2) the world-wide accepted classification of early cancer, 3) by comparison with the findings of gastrocamera and endoscopy. Main factors in double-contrast barium meal are: distention of the stomach by at least 200 cc gas, gastric atony (Glucagon or anticholinergica), visualization of the total gastric mucosa by high density, low viscosity barium after washing out the mucus from the mucosal relief. Radiological symptoms of early cancer are demonstrated, the urgency of en-face documentation of gastric ulcers is stressed.

  14. Depiction of normal gastrointestinal anatomy with MDCT: comparison of low- and high-attenuation oral contrast media.

    Science.gov (United States)

    Erturk, Sukru Mehmet; Mortelé, Koenraad J; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R

    2008-04-01

    To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Duodenal, jejunal and ileal distention (pcontrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (pcontrast medium, for reader 2. Interobserver agreement was fair to good for both distention (kappa-range: 0.41-0.74) and wall visualization (kappa-range: 0.48-0.71). MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium.

  15. Comparison of the X-ray features between child Hirschsprung alied disease and Hirschsprung disease

    International Nuclear Information System (INIS)

    Wu Shuochun; Yuan Xinyu; Bai Fengsen; Ma Lishuang; Li Long

    2010-01-01

    Objective: To compare the X-ray features between Hirschsprung alied disease (HAD) and Hirschsprung disease (HD), and analyze the differentiations. Methods: From December 2004 to December 2009, nineteen cases of HAD, aged from 30 days to 10 years (median, 14 months), received barium enema examinations in our institution. Other 19 cases with HD, also received barium enema examinations, were chosen randomly. They were aged from 42 days to 8 years (median, 8 months). The imaging features of HAD and HD were analyzed retrospectively. The incidence rate of colon stenosis, 'truncation sign' and spasm notch and R/C ratio (the longest diameter of rectum/colon) were calculated and compared between these two groups. In all these cases, diagnosis was confirmed by postoperative histopathology. The position of barium retained was also evaluated. These parameters of both groups were compared by χ 2 and Fisher test. Results: There was statistical significance in the incidence rate of' colon stenosis between HAD (9/19) and HD (18/19) (χ 2 =10.364, P 0.05 for both). R/C ratio was 0.42±0.15 in HAD group and 0.29±0.12 in HD group, and there was statistical significance between them (t=2.892, P<0.01). In HAD group, barium retained in distal sigmoid colon in 1 case (1/19), in distal descending colon in 7 cases (7/19), in distal transverse colon in 1 case (1/19), in total colon in 6 cases (6/19); However, in HD group, barium retained in distal rectum in 3 cases (3/19), in distal sigmoid colon in 13 cases (13/19), in distal descending colon in 3 cases (3/19). Conclusions: There were some differences in the imaging features between HAD and HD though they presented similar clinic experience. HAD cases presented a lower incidence rate of colon stenosis and a higher R/C ratio than HD cases. In HAD cases, the most common site of barium retained is distal descending colon, while in HD cases, it is distal sigmoid colon. (authors)

  16. Barium and radium radiopolarography

    International Nuclear Information System (INIS)

    Fourest, B.

    1979-01-01

    Radiopolarography has been applied to the study of two elements (barium and radium) which is difficult by classical polarography because of their strong electropositivity. Various parameters have been considered: nature, concentration and pH of supporting electrolyte. In any case of investigated mediums, the reduction to the metallic state reaction appeared to be reversible. An important variation of the barium half-wave potential E 1/2 with the ionic strength μ of the solution, imposed by LiCl used as supporting electrolyte, has been observed. It gives the possibility to estimate, for μ = 0, E 1/2 (Ba) = - 1.916 V/S.C.E. and E 1/2(Ra) = - 1.852 V/S.C.E. The values of barium and radium half wave potentials, obtained with a good accuracy in LiCl (or LiClO 4 ) 0.1 M medium, have been used to establish the amalgamation energy Δ 2 (M) of these elements. A linear variation of Δ 2 (M) with the metallic radius of the 2a elements has been obtained. On the other hand, by making the concentration of the complex forming agent (Cit 3- ) vary in the solution, we have a shift in the half wave potential from which we can deduce the stability constant of the complexe and its composition (BaCit - ; pK 1 =2). At last, nature and concentration of the supporting electrolyte (between 5.10 -2 M and 5M) have a determining influence on the extent of the polarogram plateau. This plateau is limited by an 'hollow effect' preceding the supporting electrolyte discharge. An interpretation of this effect is suggested which is based on the Stern model [fr

  17. Radiological demonstration of gastroesophageal reflux. Diagnostic value of barium and bread studies compared with 24-hour pH monitoring

    International Nuclear Information System (INIS)

    Aksglaede, K.; Funch-Jensen, P.; Thommesen, P.

    1999-01-01

    To correlate gastroesophageal reflux (GER), demonstrated by a radiological method using food, with the reflux events, as determined by 24-h pH monitoring. One hundred and seventeen patients with a median age of 47 years (86 male and 31 female) were examined. In the supine left position, the patient consumed 360 ml of barium contrast. Fluoroscopy was performed with the patient in the supine right oblique position during mastication and swallowing a piece of rye bread with liver pate and barium. The test was positive if barium was observed >= 5 cm proximal to the gastroesophageal junction. An antimony pH-probe was placed 5 cm above the lower esophageal sphincter, previously determined by manometry. The position was controlled by radiography after positioning and before removal. The total time of esophageal pH<4 exceeding 5.0% was considered pathological. The radiological method had a specificity of 100% and a sensitivity of 52% compared to 24-h pH monitoring. The high specificity of this radiological method justify direct therapeutic consequence of a positive test. However, a negative test still renders the problem unsolved

  18. Radiological demonstration of gastroesophageal reflux. Diagnostic value of barium and bread studies compared with 24-hour pH monitoring

    International Nuclear Information System (INIS)

    Aksglaede, K.; Thommesen, P.; Funch-Jensen, P.

    1999-01-01

    Purpose: To correlate gastroesophageal reflux (GER), demonstrated by a radiological method using food, with the reflux events, as determined by 24-h pH monitoring. Material and Methods: One hundred and seventeen patients with a median age of 47 years (86 male and 31 female) were examinated. In the supine left position, the patient consumed 360 ml of barium contrast. Fluoroscopy was performed with the patient in the supine right oblique position during mastication and swallowing a piece of rye bread with liver pate and barium. The test was positive if barium was observed ≥5 cm proximal to the gastroesophageal junction. An antimony pH-probe was placed 5 cm above the lower esophageal sphincter, previously determined by manometry. The position was controlled by radiography after positioning and before removal. The total time of esophageal pH<4 exceeding 5.0% was considered pathological. Results: The radiological method had a specificity of 100% and a sensitivity of 52% compared to 24-h pH monitoring. Conclusion: The high specificity of this radiological method justify direct therapeutic consequence of a positive test. However, a negative test still renders the problem unsolved. (orig.)

  19. Radiological demonstration of gastroesophageal reflux. Diagnostic value of barium and bread studies compared with 24-hour pH monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Aksglaede, K.; Thommesen, P. [Dept. of Diagnostic Radiology R, Aarhus Univ. Hospital, Aarhus (Denmark); Funch-Jensen, P. [Surgical Gastroenterology L, Aarhus Univ. Hospital, Aarhus (Denmark)

    1999-11-01

    Purpose: To correlate gastroesophageal reflux (GER), demonstrated by a radiological method using food, with the reflux events, as determined by 24-h pH monitoring. Material and Methods: One hundred and seventeen patients with a median age of 47 years (86 male and 31 female) were examinated. In the supine left position, the patient consumed 360 ml of barium contrast. Fluoroscopy was performed with the patient in the supine right oblique position during mastication and swallowing a piece of rye bread with liver pate and barium. The test was positive if barium was observed {>=}5 cm proximal to the gastroesophageal junction. An antimony pH-probe was placed 5 cm above the lower esophageal sphincter, previously determined by manometry. The position was controlled by radiography after positioning and before removal. The total time of esophageal pH<4 exceeding 5.0% was considered pathological. Results: The radiological method had a specificity of 100% and a sensitivity of 52% compared to 24-h pH monitoring. Conclusion: The high specificity of this radiological method justify direct therapeutic consequence of a positive test. However, a negative test still renders the problem unsolved. (orig.)

  20. Status of barium studies in the present era of oncology: Are they a history?

    Science.gov (United States)

    Mahajan, Abhishek; Desai, Subash; Sable, Nilesh Pandurang; Thakur, Meenakshi Haresh

    2016-01-01

    With the advent of the modern imaging technologies, the present era of oncology is seeing steady decline in requests for barium studies due to the many reasons. It is prudent to mention here, that, barium examinations cannot be made obsolete! Our aim to preserve the age old technique of barium studies not only to keep it going on but also for the betterment and appropriate management of the patient. Our goal is not to "save" barium studies simply to keep this technology alive, per se, but rather to preserve barium radiology for the quality in patient care.

  1. Role of Barium Swallow in Diagnosing Clinically Significant Anastomotic Leak following Esophagectomy

    Directory of Open Access Journals (Sweden)

    Simon Roh

    2016-04-01

    Full Text Available Background: Barium swallow is performed following esophagectomy to evaluate the anastomosis for detection of leaks and to assess the emptying of the gastric conduit. The aim of this study was to evaluate the reliability of the barium swallow study in diagnosing anastomotic leaks following esophagectomy. Methods: Patients who underwent esophagectomy from January 2000 to December 2013 at our institution were investigated. Barium swallow was routinely done between days 5–7 to detect a leak. These results were compared to clinically determined leaks (defined by neck wound infection requiring jejunal feeds and or parenteral nutrition during the postoperative period. The sensitivity and specificity of barium swallow in diagnosing clinically significant anastomotic leaks was determined. Results: A total of 395 esophagectomies were performed (mean age, 62.2 years. The indications for the esophagectomy were as follows: malignancy (n=320, high-grade dysplasia (n=14, perforation (n=27, benign stricture (n=7, achalasia (n=16, and other (n=11. A variety of techniques were used including transhiatal (n=351, McKeown (n=35, and Ivor Lewis (n=9 esophagectomies. Operative mortality was 2.8% (n=11. Three hundred and sixty-eight patients (93% underwent barium swallow study after esophagectomy. Clinically significant anastomotic leak was identified in 36 patients (9.8%. Barium swallow was able to detect only 13/36 clinically significant leaks. The sensitivity of the swallow in diagnosing a leak was 36% and specificity was 97%. The positive and negative predictive values of barium swallow study in detecting leaks were 59% and 93%, respectively. Conclusion: Barium swallow is an insensitive but specific test for detecting leaks at the cervical anastomotic site after esophagectomy.

  2. Studies on phase evolution and electrical conductivity of barium doped gadolinium aluminate

    International Nuclear Information System (INIS)

    Sinha, Amit; Sharma, B.P.; Gopalan, P.

    2012-01-01

    Highlights: ► Barium doped GdAlO 3 compositions were prepared from citrate gel derived powders. ► The solid solubility of barium in GdAlO 3 was less than 4 mol%. ► The un-dissolved barium precipitated in the form of BaAl 2 O 4 phase. ► The conductivity of Ba-doped GdAlO 3 increased with increasing amounts of Ba. ► In Gd 1−x Ba x AlO 3−δ system, specimen with x = 0.02 exhibited maximum conductivity. - Abstract: The phase evolution and electrical conductivity of barium doped GdAlO 3 samples have been investigated. The Ba- doped compositions of GdAlO 3 were prepared through citrate gel process. Analysis of the phases was carried out using X-ray diffraction (XRD). The morphology of the calcined powders was studied by scanning electron microscopy. The electrical conductivity of Gd 1−x Ba x AlO 3−δ (x = 0–0.04) was measured using ac impedance spectroscopy as a function of temperature ranging from 300 to 1000 °C under air. The solid solubility of barium in GdAlO 3 was found to be less than 4 mol%. The undissolved barium precipitated in the form of BaAl 2 O 4 phase. The barium doped GdAlO 3 powders obtained after calcination at 1000 °C was found to be porous agglomerate composed of nanocrystalline grains. The total electrical conductivity of Ba-doped GdAlO 3 increased with increasing amounts of barium up to 2 mol% doping.

  3. The diagnosis of gastro-esophageal reflux disease cannot be made with barium esophagograms

    NARCIS (Netherlands)

    Saleh, C. M. G.; Smout, A. J. P. M.; Bredenoord, A. J.

    2015-01-01

    For over 50 years, barium studies have been used to diagnose gastro-esophageal reflux disease (GERD), but the value of this test is controversial. Our study aimed to determine if barium esophagograms can be used to diagnose GERD. Barium esophagograms and pH-impedance measurement were performed in 20

  4. Rectosigmoid tubular duplication presenting as perineal sepsis in a neonate.

    Science.gov (United States)

    Zhang, Zhibo; Huang, Ying; Wang, Dajia; Su, Pengjun

    2010-03-01

    Tubular rectal duplication is a very rare congenital anomaly. We report a case of tubular rectal duplication in a newborn baby who presented with perianal sepsis. The diagnosis was confirmed by barium enema, magnetic resonance imaging, and at operation. We performed total mucosectomy through a posterior sagittal incision combined with laparotomy. The patient was doing quite well at 17-month follow-up examination.

  5. Prevalence of occult inflammatory bowel disease in ankylosing spondylitis.

    Science.gov (United States)

    Costello, P B; Alea, J A; Kennedy, A C; McCluskey, R T; Green, F A

    1980-10-01

    Fifty-five patients with ankylosing spondylitis and 16 control patients matched for sex and age were examined for evidence of occult inflammatory bowel disease. In all patients evaluation included history and physical examination, barium enema, sigmoidoscopy, and rectal biopsy. The results of this study suggest that there is no increased prevalence of occult inflammatory bowel disease in patients with ankylosing spondylitis.

  6. Low residual diet and hydration improving double contrast examination of the colon

    International Nuclear Information System (INIS)

    Virkki, R.; Maekelae, P.

    1983-01-01

    Light food diet and low residual diet with hydration, both combined with Proctosal and Bisacodyl cleansing, were compared in 268 patients in the preparation of the colon for double contrast examination. Low residual diet with hydration resulted in significantly less residual fecal material, no flocculation of the barium coating and significantly denser mucosal coating. The examination had to be repeated more often (8.6%) after light food diet than after low residual diet with hydration (1.7%), but there was no statistically significant difference in the diagnostic accuracy. The hydration is important in avoiding patient discomforts and flocculation of the barium coating. Despite the use of laxatives, a strict diet restriction is needed to obtain consistently clean colon. (orig.)

  7. Barium contributions to the valence electronic structure of YBa2Cu3O7-δ, PrBa2Cu3O7-δ, and other barium-containing compounds

    International Nuclear Information System (INIS)

    Mueller, D.R.; Wallace, J.S.; Jia, J.J.; O'Brien, W.L.; Dong, Q.; Callcott, T.A.; Miyano, K.E.; Ederer, D.L.

    1995-01-01

    Monochromatic photon beams were used to excite barium N IV,V soft x-ray emission spectra from YBa 2 Cu 3 O 7-δ , PrBa 2 Cu 3 O 7-δ , BaF 2 , and BaTiO 3 . Near threshold excitation was used to demonstrate that small contributions to the barium N V and N IV emission spectra in the energy region above the 5p→4d core-core transitions do not arise as satellite emission from transitions in multiply excited atoms but rather occur as a result of transitions from the valence states. The emission spectrum of YBa 2 Cu 3 O 7-δ and PrBa 2 Cu 3 O 7-δ reveals a contribution to the electronic density of states at the barium site in the region near the Fermi level. The YBa 2 Cu 3 O 7-δ compound is a superconductor and PrBa 2 Cu 3 O 7-δ is an insulator. It has been proposed that the difference between them is due to mixing of praseodymium and barium among the sites occupied by yttrium and barium, with an accompanying change in electronic structure. However, our measurements indicate that the barium partial density of states for the two compounds are essentially identical

  8. Synthesis and properties of barium diketonates as precursors for MOCVD

    Energy Technology Data Exchange (ETDEWEB)

    Drozdov, A.A. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Troyanov, S.I. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Kuzmina, N.P. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Martynenko, L.I. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Alikhanyan, A.S. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Malkerova, I.P. (Dept. of Chemistry, Moscow State Univ. (Russian Federation))

    1993-08-01

    The structures of barium diketonates depend on the way in which they are synthesized. It is shown that there is a correlation between the volatility of these compounds and their crystal structures. A new volatile mononuclear adduct of barium dipivaloylmethanate suitable for MOCVD is suggested. (orig.).

  9. Synthesis and properties of barium diketonates as precursors for MOCVD

    International Nuclear Information System (INIS)

    Drozdov, A.A.; Troyanov, S.I.; Kuzmina, N.P.; Martynenko, L.I.; Alikhanyan, A.S.; Malkerova, I.P.

    1993-01-01

    The structures of barium diketonates depend on the way in which they are synthesized. It is shown that there is a correlation between the volatility of these compounds and their crystal structures. A new volatile mononuclear adduct of barium dipivaloylmethanate suitable for MOCVD is suggested. (orig.)

  10. Barium hexaferrite nanoparticles: Synthesis and magnetic properties

    International Nuclear Information System (INIS)

    Martirosyan, K.S.; Galstyan, E.; Hossain, S.M.; Wang Yiju; Litvinov, D.

    2011-01-01

    Carbon combustion synthesis is applied to rapid and energy efficient fabrication of crystalline barium hexaferrite nanoparticles with the average particle size of 50-100 nm. In this method, the exothermic oxidation of carbon nanoparticles with an average size of 5 nm with a surface area of 80 m 2 /g generates a self-propagating thermal wave with maximum temperatures of up to 1000 deg. C. The thermal front rapidly propagates through the mixture of solid reactants converting it to the hexagonal barium ferrite. Carbon is not incorporated in the product and is emitted from the reaction zone as a gaseous CO 2 . The activation energy for carbon combustion synthesis of BaFe 12 O 19 was estimated to be 98 kJ/mol. A complete conversion to hexagonal barium ferrite is obtained for carbon concentration exceeding 11 wt.%. The magnetic properties H c ∼3000 Oe and M s ∼50.3 emu/g of the compact sintered ferrites compare well with those produced by other synthesis methods.

  11. Atomization of magnesium, strontium, barium and lead nitrates on surface of graphite atomizers

    International Nuclear Information System (INIS)

    Nagdaev, V.K.; Pupyshev, A.A.

    1982-01-01

    Modelling of the processes on graphite surface using differential-thermal analysis and graphite core with identification of decomposition products of magnesium, strontium, barium and lead nitrates by X-ray analysis has shown that carbon promotes the formation of strontium, barium and lead carbonates. The obtained temperatures of strontium and barium carbonate decomposition to oxides agree satisfactorily with calculation ones. Magnesium nitrate does not react with carbon. Formation of strontium and barium carbonates results in considerable slowing down of the process of gaseous oxide dissociation. Lead carbonate is unstable and rapidly decomposes to oxide with subsequent reduction to free metal. Formation of magnesium, strontium and barium free atoms is connected with appearance of gaseous oxides in analytical zone. Oxide and free metal lead are present on graphite surface simultaneously

  12. Accuracy of the double contrast technique in the detection of small lesions of the colon

    Energy Technology Data Exchange (ETDEWEB)

    Muzzio, P C; Pomerri, F; Feltrin, G P; Biondetti, P R; Di Maggio, C [Padua Univ. (Italy). Istituto di Radiologia e Fisioterapia

    1979-02-01

    Double contrast enema has become an indispensible aid in early lesions of the colon, in particular for small lesions. According to the authors' opinion, the method provides so much additional information that it ought to be applied at all rates in such cases. It is neither expensive nor time-consuming and can easily be carried out in any X-ray department, especially where a fibroscope is not available. The results are reliable if the technique is applied correctly, if the patient is well-prepared, and if the radiologist has enough technical and semiological experience.

  13. Oral contrast agents for small bowel distension in MRI: influence of the osmolarity for small bowel distention

    International Nuclear Information System (INIS)

    Ajaj, Waleed; Kuehle, Christiane; Nuefer, Michael; Goehde, Susanne C.; Lauenstein, Thomas C.; Goyen, Mathias; Schneemann, Hubert; Ruehm, Stefan G.

    2005-01-01

    To assess the effect of the osmolarity for small bowel distension in MRI, ten volunteers ingested at two separate occasions negative oral contrast agents with different quantity and osmolarity: (1) a water solution combined with 2.0% sorbitol and 0.2% locus bean gum (LBG) with a quantity of 1500 ml and an osmolarity of 148 mOsmol/l, (2) a water solution combined with 2.0% sorbitol and 2.0% barium sulphate with a quantity of 1000 ml and an osmolarity of 194 mOsmol/l. Small bowel distension was quantified on coronal 2D-TrueFISP images by measuring the small bowel diameters. There were no statistically significant differences in mean small bowel diameter between both contrast agents. The mean small bowel distension was 19.2 mm after ingestion of 1500 ml of sorbitol-LBG solution and 19.0 mm after ingestion of 1000-ml sorbitol-barium sulphate solution. Furthermore, all volunteers found the ingestion of 1000-ml solution more pleasant than the 1500-ml solution. The ingestion of 1000 ml of sorbitol-barium sulphate solution led to a sufficient small bowel distension compared to 1500 ml of sorbitol-LBG solution. The side effect rate of both solutions was low. Based on these data, we recommend a quantity of 1000 ml of sorbitol-barium sulphate solution as an alternative for 1500-ml sorbitol-LBG solution for optimal bowel distension. (orig.)

  14. Synthesis and surface properties of submicron barium sulfate particles

    International Nuclear Information System (INIS)

    Zhang Ming; Zhang Bao; Li Xinhai; Yin Zhoulan; Guo Xueyi

    2011-01-01

    Barium sulfate particles were synthesized in the presence of EDTA at room temperature. X-ray diffractometry (XRD), Fourier transform infrared resonance (FTIR) and scanning electron microscopy (SEM) were used to characterize the structure and morphology of BaSO 4 particles. The effect of the preparation parameters on the particle size distribution and morphology was investigated. The conditional formation constants of Ba-EDTA at different pH values were calculated. The results show that the size and morphology of BaSO 4 particles can be effectively controlled by adding EDTA in the precipitation process. Among all the operation conditions, the pH value has significant effect on the particle size. The obtained barium sulfate particles are spherical and well dispersed at pH = 9-10. Zeta potentials of BaSO 4 were measured at different pH. The isoelectric point (IEP) of barium sulfate colloid appears at pH 6.92. The model of the solid-solution interface at a particle of BaSO 4 was presented. The FTIR result indicates that the surface of the prepared BaSO 4 absorbs the functional groups of EDTA, which lower the IEP of the barium sulfate particles.

  15. Synthesis and surface properties of submicron barium sulfate particles

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Ming, E-mail: csu.light@yahoo.com.cn [College of Chemistry and Chemical Engineering, Zhaoqing University, Zhaoqing 526061 (China); School of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); Zhang Bao; Li Xinhai [School of Metallurgical Science and Engineering, Central South University, Changsha 410083 (China); Yin Zhoulan [School of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); Guo Xueyi [School of Metallurgical Science and Engineering, Central South University, Changsha 410083 (China)

    2011-10-15

    Barium sulfate particles were synthesized in the presence of EDTA at room temperature. X-ray diffractometry (XRD), Fourier transform infrared resonance (FTIR) and scanning electron microscopy (SEM) were used to characterize the structure and morphology of BaSO{sub 4} particles. The effect of the preparation parameters on the particle size distribution and morphology was investigated. The conditional formation constants of Ba-EDTA at different pH values were calculated. The results show that the size and morphology of BaSO{sub 4} particles can be effectively controlled by adding EDTA in the precipitation process. Among all the operation conditions, the pH value has significant effect on the particle size. The obtained barium sulfate particles are spherical and well dispersed at pH = 9-10. Zeta potentials of BaSO{sub 4} were measured at different pH. The isoelectric point (IEP) of barium sulfate colloid appears at pH 6.92. The model of the solid-solution interface at a particle of BaSO{sub 4} was presented. The FTIR result indicates that the surface of the prepared BaSO{sub 4} absorbs the functional groups of EDTA, which lower the IEP of the barium sulfate particles.

  16. Printed Barium Strontium Titanate capacitors on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Sette, Daniele [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Luxembourg Institute of Science and Technology LIST, Materials Research and Technology Department, L-4422 Belvaux (Luxembourg); Kovacova, Veronika [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Defay, Emmanuel, E-mail: emmanuel.defay@list.lu [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Luxembourg Institute of Science and Technology LIST, Materials Research and Technology Department, L-4422 Belvaux (Luxembourg)

    2015-08-31

    In this paper, we show that Barium Strontium Titanate (BST) films can be prepared by inkjet printing of sol–gel precursors on platinized silicon substrate. Moreover, a functional variable capacitor working in the GHz range has been made without any lithography or etching steps. Finally, this technology requires 40 times less precursors than the standard sol–gel spin-coating technique. - Highlights: • Inkjet printing of Barium Strontium Titanate films • Deposition on silicon substrate • Inkjet printed silver top electrode • First ever BST films thinner than 1 μm RF functional variable capacitor that has required no lithography.

  17. Rapid and accurate determination of barium by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Armelin, Maria Jose A.; Maihara, Vera A.; Saiki, Mitiko; Trevizam, Anderson R.

    2013-01-01

    Barium is an alkaline earth metal naturally present in soils. When available at a high level in the soil it can cause toxicity to plants and animals. Not all the barium is readily available to living organisms. Inorganic and organic barium compounds can be presented as soluble or insoluble forms in the soil. The soluble form of BaS is extremely toxic to humans, animals and plants. Researchers have noted a decrease of K absorption in the plant when Ba concentrations are increased and a change in overall plant growth. In case of animals, Ba tends to be concentrated in the bones which may compete with calcium, although only about 2% barium ingested in dietary is absorbed by the body. Another effect is that the Ba can interfere with the availability of sulfur in the soil due to the sulphate formation of low solubility. Barium and some other elements are considered palioclimatic proxies. For some researchers, barite is perhaps the most appropriate indicator of paleoproductivity because of a high resistance to dissolution. As explained about the barium effects in various situations, it was considered important to study the more appropriated experimental conditions for determination of this element by INAA. Conditions established for this analysis were: a) Irradiation time, 15 and 40 seconds, under thermal flux neutron about 4 x 10 12 n cm -2 s -1 , for determining barium in geological and biological matrices, respectively; b) Decay time, approximately of 4 minutes; c) Counting time of 30 minutes; d) Radionuclide measured 139 Ba. The quality of Ba results was evaluated from the analysis of certified reference materials. The performance of the method was satisfactory, according to the criterion of E.ζ score. Results obtained in this study indicate INAA is a good alternative for Ba determination in geological and biological samples. (author)

  18. Congenital retrosternal hernias of Morgagni: Manifestation and treatment in children

    Directory of Open Access Journals (Sweden)

    Oleksii Slepov

    2016-01-01

    Full Text Available Background: Due to scarcity of congenital diaphragmatic hearnias of Morgagni (CDHM, non-specific clinical presentation in the pediatric age group, we aimed to investigate the incidence, clinical manifestations, anatomical characteristics, and develop diagnostic algorithm and treatment of CDHM in children. Materials and Methods: The patients′ records of children with CDHM treated in our hospital during past 20 years were retrospectively reviewed for the age at diagnosis, gender, clinical findings, anatomical features, operative details and outcome. Results: Since 1995 to 2014 we observed 6 (3 boys, 3 girls patients with CDHM, that comprise 3.2% of all congenital diaphragmatic hernia cases (n = 185. Age at diagnosis varied from 3 mo. to 10y.o. Failure to thrive was main symptom in 4 patients, followed by recurrent respiratory infections (n = 3, dyspnea (n = 3, and gastrointestinal manifestations: constipation (n = 2, abdominal pain (n = 1. Work-up consisted of plain X-ray for all (n = 6, upper GI (n = 3, barium enema (n = 2, sonography (n = 6 and CT (n = 2. Abdominal approach used in 5 patients, and thoracotomy in one. Herniated contents were: liver lobes (n = 4, transverse colon (n = 3 and greater omentum (n = 1. 5 had right-sided lesion, 1- left-sided. Defect repaired using local tissues. Post-operative course was uneventful; all patients appeared well during follow-up. Conclusion: CDHM is very uncommon anomaly, very occasionally diagnosed at the early age. Failure to thrive and recurrent respiratory infections are most frequent clinical manifestations. In suspected CDHM we advocate the following work-up: plain chest and abdominal X-ray, contrast study (upper GI series or barium enema, ultrasonographic screen and CT scan. Surgical repair via abdominal approach, using local tissues and hernia sac removal is preferred.

  19. Persistent demographic differences in colorectal cancer screening utilization despite Medicare reimbursement

    Directory of Open Access Journals (Sweden)

    Kreuter William

    2005-03-01

    Full Text Available Abstract Background Colorectal cancer screening is widely recommended, but often under-utilized. In addition, significant demographic differences in screening utilization exist. Insurance coverage may be one factor influencing utilization of colorectal cancer screening tests. Methods We conducted a retrospective analysis of claims for outpatient services for Washington state Medicare beneficiaries in calendar year 2000. We determined the proportion of beneficiaries utilizing screening fecal occult blood tests, flexible sigmoidoscopy, colonoscopy, or double contrast barium enema in the overall population and various demographic subgroups. Multiple logistic regression analysis was used to determine the relative odds of screening in different demographic groups. Results Approximately 9.2% of beneficiaries had fecal occult blood tests, 7.2% had any colonoscopy, flexible sigmoidoscopy, or barium enema (invasive colon tests, and 3.5% had invasive tests for screening indications. Colonoscopy accounted for 41% of all invasive tests for screening indications. Women were more likely to receive fecal occult blood test screening (OR 1.18; 95%CI 1.15, 1.21 and less likely to receive invasive tests for screening indications than men (OR 0.80, 95%CI 0.77, 0.83. Whites were more likely than other racial groups to receive any type of screening. Rural residents were more likely than urban residents to have fecal occult blood tests (OR 1.20, 95%CI 1.17, 1.23 but less likely to receive invasive tests for screening indications (OR 0.89; 95%CI 0.85, 0.93. Conclusion Reported use of fecal occult blood testing remains modest. Overall use of the more invasive tests for screening indications remains essentially unchanged, but there has been a shift toward increased use of screening colonoscopy. Significant demographic differences in screening utilization persist despite consistent insurance coverage.

  20. CT Image Contrast of High-Z Elements: Phantom Imaging Studies and Clinical Implications.

    Science.gov (United States)

    FitzGerald, Paul F; Colborn, Robert E; Edic, Peter M; Lambert, Jack W; Torres, Andrew S; Bonitatibus, Peter J; Yeh, Benjamin M

    2016-03-01

    To quantify the computed tomographic (CT) image contrast produced by potentially useful contrast material elements in clinically relevant imaging conditions. Equal mass concentrations (grams of active element per milliliter of solution) of seven radiodense elements, including iodine, barium, gadolinium, tantalum, ytterbium, gold, and bismuth, were formulated as compounds in aqueous solutions. The compounds were chosen such that the active element dominated the x-ray attenuation of the solution. The solutions were imaged within a modified 32-cm CT dose index phantom at 80, 100, 120, and 140 kVp at CT. To simulate larger body sizes, 0.2-, 0.5-, and 1.0-mm-thick copper filters were applied. CT image contrast was measured and corrected for measured concentrations and presence of chlorine in some compounds. Each element tested provided higher image contrast than iodine at some tube potential levels. Over the range of tube potentials that are clinically practical for average-sized and larger adults-that is, 100 kVp and higher-barium, gadolinium, ytterbium, and tantalum provided consistently increased image contrast compared with iodine, respectively demonstrating 39%, 56%, 34%, and 24% increases at 100 kVp; 39%, 66%, 53%, and 46% increases at 120 kVp; and 40%, 72%, 65%, and 60% increases at 140 kVp, with no added x-ray filter. The consistently high image contrast produced with 100-140 kVp by tantalum compared with bismuth and iodine at equal mass concentration suggests that tantalum could potentially be favorable for use as a clinical CT contrast agent.

  1. Measurement of microbic contamination rate in the dispensing process making suspension of barium sulfate powder

    International Nuclear Information System (INIS)

    Kim, Young Keun; Lee, Yang Sub; Cho, Cheong Chan; Ryu, Meung Sun; Lee, Kyung Sup

    2001-01-01

    The purpose of this study is to investigate the contamination rate of barium sulfate suspension made in the exposed state in usual circumstances. This study was performed in four university hospital using the contrast media by barium sulfate powder. The specimen were detected at dispensing water, agitator and mixing tank. We also classified the suspension into general bacteria, mycete and Bacillus coli infection. The tap water were used to dispense water in the all hospitals. Bacillus coli were not detected in the all. General bacteria and mycete were not detected in the one specimen, but detected in two specimen over defined value. In the contamination rate of agitator, mixing tank, and the manufactured. Bacillus coli were not detected in all. However, general bacteria and mycete were detected too numberous to count. In conclusion, the refined water must be used in dispensing water in manufacturing suspension. The disinfectant is also used in washing the agitator and mixing tank for sterilization. Hand washing is indispensable to manufacturing suspension for preventing from infection

  2. TV observations of the Barium-GEOS ion jet experiment

    International Nuclear Information System (INIS)

    Hapgood, M.A.; Collin, H.L.; Rothwell, P.

    1980-01-01

    The barium jet released by the Barium-GEOS rocket was observed by low light television cameras at Skibotn, Norway and Esrange, Sweden. The release produced a single well-defined jet containing barium ions with initial velocities between 7 and 12 km s -1 systematically slower than the velocities reported in previous experiments. Accurate data on the motion of the jet has been obtained for the first two minutes after release (up to a height of 2000 km). The orientation of the jet was close to that of an IGRF1975 model field line but was significantly different from that predicted by the Barraclough and Olson field model. The motion of the jet across the field lines was southwards with a velocity of about 150 m s -1 . (Auth.)

  3. Barium titanate thick films prepared by screen printing technique

    Directory of Open Access Journals (Sweden)

    Mirjana M. Vijatović

    2010-06-01

    Full Text Available The barium titanate (BaTiO3 thick films were prepared by screen printing technique using powders obtained by soft chemical route, modified Pechini process. Three different barium titanate powders were prepared: i pure, ii doped with lanthanum and iii doped with antimony. Pastes for screen printing were prepared using previously obtained powders. The thick films were deposited onto Al2O3 substrates and fired at 850°C together with electrode material (silver/palladium in the moving belt furnace in the air atmosphere. Measurements of thickness and roughness of barium titanate thick films were performed. The electrical properties of thick films such as dielectric constant, dielectric losses, Curie temperature, hysteresis loop were reported. The influence of different factors on electrical properties values was analyzed.

  4. Effects of powdered versus liquid barium on the viscosity of fluids used in modified swallow studies

    International Nuclear Information System (INIS)

    Baron, J.; Alexander, T.

    2003-01-01

    To determine if the viscosity of thickened juice mixtures used in modified barium swallow studies significantly changes with the addition of powdered barium. We also describe a test formulation created using liquid barium, which has a negligible effect on juice viscosity. The viscosities of water and standardized honey- and nectar-consistency juices mixed with different amounts of powdered barium were measured by timing the laminar flow of a given initial hydrostatic head of fluid under gravity though an orifice of fixed diameter. Standardized juices were then mixed with a liquid formulation of barium and with measured quantities of water to produce viscosities that more closely equated with those of the standardized juices. With the addition of powdered barium, viscosity increased in all fluids, most markedly with the nectar-consistency juice. Liquid barium formulations maintained the viscosities of the original thickened juices. Rendering juices radio-opaque with barium powder results in dramatic increases in the viscosity of the resulting mixture and compromises diagnostic accuracy. Liquid barium preparations have the advantage that they can be rapidly and accurately dispensed by syringe, and their use does not significantly increase the viscosity of the preparation. (author)

  5. Effects of powdered versus liquid barium on the viscosity of fluids used in modified swallow studies

    Energy Technology Data Exchange (ETDEWEB)

    Baron, J.; Alexander, T. [Univ. of Alberta, Dept. of Radiology, Edmonton, Alberta (Canada)

    2003-06-01

    To determine if the viscosity of thickened juice mixtures used in modified barium swallow studies significantly changes with the addition of powdered barium. We also describe a test formulation created using liquid barium, which has a negligible effect on juice viscosity. The viscosities of water and standardized honey- and nectar-consistency juices mixed with different amounts of powdered barium were measured by timing the laminar flow of a given initial hydrostatic head of fluid under gravity though an orifice of fixed diameter. Standardized juices were then mixed with a liquid formulation of barium and with measured quantities of water to produce viscosities that more closely equated with those of the standardized juices. With the addition of powdered barium, viscosity increased in all fluids, most markedly with the nectar-consistency juice. Liquid barium formulations maintained the viscosities of the original thickened juices. Rendering juices radio-opaque with barium powder results in dramatic increases in the viscosity of the resulting mixture and compromises diagnostic accuracy. Liquid barium preparations have the advantage that they can be rapidly and accurately dispensed by syringe, and their use does not significantly increase the viscosity of the preparation. (author)

  6. Barium fluoride surface preparation, analysis and UV reflective coatings at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Wuest, C.R.

    1992-01-01

    Lawrence Livermore National Laboratory (LLNL) has begun a program of study on barium fluoride scintillating crystals for the Barium Fluoride Electromagnetic Calorimeter Collaboration. This program has resulted in a number of significant improvements in the mechanical processing, polishing and coating of barium fluoride crystals. Techniques have been developed using diamond-loaded pitch lapping that can produce 15 angstrom RMS surface finishes over large areas. These lapped surfaces have been shown to be crystalline using Rutherford Back-scattering (RBS). Also, special polishing fixtures have been designed based on mounting technology developed for the 1.1 m diameter optics used in LLNL's Nova Laser. These fixtures allow as many as five 25--50 cm long barium fluoride crystals to be polished and lapped at a time with the necessary tolerances for the 16,000 crystal Barium Fluoride Calorimeter. In addition, results will be presented on coating barium fluoride with UV reflective layers of magnesium fluoride and aluminum

  7. Experimental studies on 3D printing of barium titanate ceramics for medical applications

    Directory of Open Access Journals (Sweden)

    Schult Mark

    2016-09-01

    Full Text Available The present work deals with the 3D printing of porous barium titanate ceramics. Barium titanate is a biocompatible material with piezoelectric properties. Due to insufficient flowability of the starting material for 3D printing, the barium titanate raw material has been modified in three different ways. Firstly, barium titanate powder has been calcined. Secondly, flow additives have been added to the powder. And thirdly, flow additives have been added to the calcined powder. Finally, a polymer has been added to the three materials and specimens have been printed from these three material mixtures. The 3D printed parts were then sintered at 1320°C. The sintering leads to shrinkage which differs between 29.51–71.53% for the tested material mixtures. The porosity of the parts is beneficial for cell growth which is relevant for future medical applications. The results reported in this study demonstrate the possibility to fabricate porous piezoelectric barium titanate parts with a 3D printer that can be used for medical applications. 3D printed porous barium titanate ceramics can especially be used as scaffold for bone tissue engineering, where the bone formation can be promoted by electrical stimulation.

  8. Barium ionization mechanisms in the CRRES G-1 and G-11b releases

    International Nuclear Information System (INIS)

    Hunton, D.E.

    1993-01-01

    The G-11b chemical release experiment form the Combined Release and Radiation Effects Satellite (CRRES) was conducted in darkness below the solar UV terminator to test the Critical Ionization Velocity (CIV) hypothesis. The Quadrupole Ion Mass Spectrometer (QIMS) aboard CRRES measured fluxes of barium ions from this darkness release that were only a factor of ten smaller than the G-1 release measurements in full sunlight. Possible mechanisms for this significant barium ionization in darkness include CIV, charge exchange with O + , collisional ionization and associative ionization. The authors have evaluated the relative contributions of the collisional mechanisms by constructing a simple model of barium ions from the darkness release seem to be consistent with recent measurements of the charge transfer cross section. A collective plasma ionization mechanism such as CIV does not seem to necessary in order to explain the large barium ion fluxes observed. However, QIMS could only detect barium ions formed several seconds after the initial detonation of the release canister. A CIV process could still have occurred very early in the expansion of the barium neutral cloud and the mass spectrometer would not have detected these ions

  9. Técnicas y procedimientos: Sondaje rectal. Administración de un enema de limpieza. Extracción de fecalomas

    OpenAIRE

    Luis Rodrigo, María Teresa; Giménez Maroto, Ana Ma

    2001-01-01

    Sondaje rectal. Definición: Introducción de una sonda flexible a través de los esfínteres anales externo e interno. Objetivo: Administrar un enema o ayudar a reducir la flatulencia. Material: Sonda rectal, lubricante, empapador, guantes limpios, esparadrapo antialérgico y bolsa colectora (opcional)...

  10. Gas thermodesorption study of barium and strontium cerates

    International Nuclear Information System (INIS)

    Aksenova, T.I.; Khromushin, I.V.; Zhotabaev, Zh.R.; Bukenov, K.D.; Medvedeva, Z.V.; Berdauletov, A.K.

    2002-01-01

    Kinetic of water, oxygen, hydrogen and carbon dioxide molecules release from doped and undoped samples of barium cerates and doped strontium cerates during vacuum heating was studied. The samples were prepared by inductive melting method. The following two kinds of preliminary samples treatments were used: annealing in air (650-750 deg. C) and wet nitrogen atmosphere (625 deg.C). Main results of thermodesorption studies of barium and strontium cerates are represented in the table. The samples of doped LaSrMnO were investigated also. It was found that the initial doped samples (without preliminary annealing) did not show any gas release in temperature range of 20-1100 deg. C. This fact indicates on high stability of compositions and strong bond of 'host' oxygen in their lattice. A significant amount of water and oxygen molecules were released from BaCe 0.9 Nd 0.1 O 3 samples whereas water and hydrogen molecules desorption from SrCe 0.95 Y 0.05 O 3 samples took place. Hydrogen molecules desorption was found for strontium cerates samples; no hydrogen molecules release was observed for doped and pure barium cerate samples.Intensive water molecules release from doped samples confirms the necessity of oxygen vacancies creation in these compounds to get properties of proton conductivity, since it was not found any water molecules release from annealed undoped samples of BaCeO 3 It is necessary to notice that oxygen molecules release from these samples took place at ∼1000 deg. C that is significantly higher then from BaCeNdO samples. Forms of high temperatures part of oxygen and low temperature part of water spectra indicate that phase transformations are responsible for oxygen and water molecules desorption in this cases. These results are in good agreement with literature data. Desorption of water molecules from barium and strontium cerates took place. Oxygen desorption took place only from barium cerates. It can be explained as the following: doped barium cerates have

  11. Complete sulphate removal from neutralised acidic mine drainage with barium carbonate

    CSIR Research Space (South Africa)

    Swanepoel, H

    2012-03-01

    Full Text Available -barium-calcium) Desalination process which uses barium salts to further reduce the sulphate concentration to acceptable levels with the added advantage that sulphate removal can be controlled due to the low solubility of BaSO4. This paper reports on the results...

  12. Barium titanate coated with magnesium titanate via fused salt method and its dielectric property

    International Nuclear Information System (INIS)

    Chen Renzheng; Cui Aili; Wang Xiaohui; Li Longtu

    2003-01-01

    Barium titanate fine particles were coated homogeneously with magnesium titanate via the fused salt method. The thickness of the magnesium titanate film is 20 nm, as verified by TEM and XRD. The mechanism of the coating is that: when magnesium chloride is liquated in 800 deg. C, magnesium will replace barium in barium titanate, and form magnesium titanate film on the surface of barium titanate particles. Ceramics sintered from the coated particles show improved high frequency ability. The dielectric constant is about 130 at the frequency from 1 to 800 MHz

  13. Barium in produced water: Is it a toxicological hazard to the marine environment?

    International Nuclear Information System (INIS)

    Neff, J.M.

    1993-01-01

    Produced water is a complex aqueous mixture of organic and inorganic chemicals that often is generated in large volumes as a by-product of production of oil and gas. Produced water from offshore oil production platforms sometimes is treated to remove particulate oil and then discharged to the ocean. Barium often is the most abundant inorganic chemical, other than the dominant sea salts, in produced water. Some concern has been expressed that the large amounts of barium discharged to the ocean in produced water may have adverse effects on marine biological communities. The ecological risks associated with discharge to the ocean in produced water may have adverse effects on marine biological communities. The ecological risks associated with discharge to the ocean of barium in produced water were evaluated. Concentrations of barium in produced water from different sources range from less than 1.0 to about 2,000 mg/L, and are inversely correlated with concentrations of sulfate. Concentrations of barium in the ocean usually are in the range of 10 to 20 μg/L; the ocean is undersaturated with respect to barite (BaSO 4 ). During mixing and dilution of a produced water plume in the ocean, barium reacts with the abundant sulfate in seawater and precipitates as barite. Barite is completely nontoxic to marine organisms. Because of the high concentration of sulfate in the ocean, ionic barium can not reach concentrations high enough to be toxic to marine organisms

  14. Look Out before Polypectomy in Patients with Diverticular Disease – A Case of a Large, Inverted Diverticulum of the Colon Resembling a Pedunculated Polyp

    Directory of Open Access Journals (Sweden)

    Omero Alessandro Paoluzi

    2010-01-01

    Full Text Available Diverticular disease of the colon may be responsible for abdominal symptoms requiring colonoscopy, which may reveal the presence of concomitant polyps. A polyp found during colonoscopy in patients with colonic diverticular disease may be removed by endoscopic polypectomy with electrosurgical snare, a procedure associated with an incidence of perforation of less than 0.05%. The risk of such a complication may be higher in the event of an inverted colonic diverticulum, which may be misinterpreted as a polypoid lesion at colonoscopy. To date, fewer than 20 cases of inverted colonic diverticula, diagnosed at colonoscopy or following air contrast barium enema, have been reported in the literature. The present report describes a 68-year-old woman who underwent a screening colonoscopy, which revealed a voluminous pedunculated polyp that was recognized to be an inverted giant colonic diverticulum before endoscopic polypectomy.

  15. Formation of barium strontium titanate powder by solid state reaction using different calcination temperatures

    International Nuclear Information System (INIS)

    Teoh Wah Tzu; Ahmad Fauzi Mohd Noor; Zainal Arifin Ahmad

    2002-01-01

    The unique electrical properties of large permittivity in Barium Strontium Titanate have been widely used to make capacitors; it can be produced by solid state reaction. In this study, the mixture of Barium Carbonate, Strontium Carbonate and Titanium Dioxide was calcined at 500 degree C, 1000 degree C, 1100 degree C , 1150 degree C, 1200 degree C, 1250 degree C and 1300 degree C. The results of the phases change in each stage were investigated via X ay Diffraction. The results show that the formation of Barium Strontium Titanate started at 1100 degree C with the presence of other phases. The mixture is fully reacted to form Barium Strontium Titanate at 1150 degree C. Only Barium Strontium Titanate was formed as the calcination temperature was set higher. (Author)

  16. Influence of fuel ratios on auto combustion synthesis of barium ferrite ...

    Indian Academy of Sciences (India)

    Unknown

    Influence of fuel ratios on auto combustion synthesis of barium ferrite nano particles. D BAHADUR*, S RAJAKUMAR and ANKIT KUMAR. Department of Metallurgical Engineering and Materials Science, Indian Institute of Technology,. Mumbai 400 076 e-mail: dhirenb@iitb.ac.in. Abstract. Single-domain barium ferrite nano ...

  17. Strontium-90 sorption from fresh waters in the process of barium manganite modification

    International Nuclear Information System (INIS)

    Ryzhen'kov, A.P.; Egorov, Yu.V.

    1995-01-01

    Strontium-90 extraction by barium manganite from fresh water (natural non-salty water in open ponds) may be increased adding to the solution the sulfate anion containing reagents that modify a sorbent and chemically bind a sorbate. Heterogeneous anion-exchanging reaction of barium manganite transformation into barium sulfate-manganese dioxide and simultaneous coprecipitation of strontium sulfate (microelement) occur as a result of it. 9 refs., 4 figs., 1 tab

  18. Characterization of barium titanate powder doped with sodium and potassium ions by using Rietveld refining

    International Nuclear Information System (INIS)

    Andrade, M.C.; Assis, J.T.; Pereira, F.R.

    2009-01-01

    A solid-reaction synthesis of doped barium titanate was done by employing barium carbonates, sodium, potassium and titanium oxides with classic procedures. Rietveld refining of X ray diffraction data of perovskite samples with tetragonal symmetry was applying and show good agreement. Besides, the treatment performed from 600 deg C produces nanocrystals of barium titanate with average size of 33 nm. The presence of endothermic peaks related to BaTiO 3 formation at relatively low temperatures was determined by thermal analysis. A pseudo-Voigt Thompson-Cox-Hastings function was used to fit the standard samples of barium titanate. The Rietveld method has showed be efficient to detect the influences of temperature and doping on barium titanate microstructures. (author)

  19. How does esophagus look on barium esophagram in pediatric eosinophilic esophagitis?

    Science.gov (United States)

    Al-Hussaini, Abdulrahman; AboZeid, Amany; Hai, Abdul

    2016-08-01

    The clinical, endoscopic, and histologic findings of eosinophilic esophagitis (EoE) are well characterized; however, there have been very limited data regarding the radiologic findings of pediatric EoE. We report on the radiologic findings of pediatric EoE observed on barium esophagram and correlate them with the endoscopic findings. We identified children diagnosed with EoE in our center from 2004 to 2015. Two pediatric radiologists met after their independent evaluations of each fluoroscopic study to reach a consensus on each case. Clinical and endoscopic data were collected by retrospective chart review. Twenty-six pediatric EoE cases (age range 2-13 years; median 7.5 years) had barium esophagram done as part of the diagnostic approach for dysphagia. Thirteen children had abnormal radiologic findings of esophagus (50%): rings formation (n = 4), diffuse irregularity of mucosa (n = 8), fixed stricture formation (n = 3), and narrow-caliber esophagus (n = 10). Barium esophagram failed to show one of 10 cases of narrow-caliber esophagus and 10 of 14 cases of rings formation visualized endoscopically. The mean duration of symptoms prior to diagnosis of EoE was longer (3.7 vs. 1.7 year; p value 0.019), and the presentation with intermittent food impaction was commoner in the group with abnormal barium esophagram as compared to the group with normal barium esophagram (69% vs. 8%; p value 0.04). Barium swallow study is frequently normal in pediatric EoE. With the exception of narrow-caliber esophagus, our data show poor correlation between radiologic and endoscopic findings.

  20. Tunable ferromagnetic resonance in La-Co substituted barium hexaferrites at millimeter wave frequencies

    Science.gov (United States)

    Korolev, Konstantin A.; Wu, Chuanjian; Yu, Zhong; Sun, Ke; Afsar, Mohammed N.; Harris, Vincent G.

    2018-05-01

    Transmittance measurements have been performed on La-Co substituted barium hexaferrites in millimeter waves. Broadband millimeter-wave measurements have been carried out using the free space quasi-optical spectrometer, equipped with a set of high power backward wave oscillators covering the frequency range of 30 - 120 GHz. Strong absorption zones have been observed in the millimeter-wave transmittance spectra of all La-Co substituted barium hexaferrites due to the ferromagnetic resonance. Linear shift of ferromagnetic resonance frequency as functions of La-Co substitutions have been found. Real and imaginary parts of dielectric permittivity of La-Co substituted barium hexaferrites have been calculated using the analysis of recorded high precision transmittance spectra. Frequency dependences of magnetic permeability of La-Co substituted barium hexaferrites, as well as saturation magnetization and anisotropy field have been determined based on Schlömann's theory for partially magnetized ferrites. La-Co substituted barium hexaferrites have been further investigated by DC magnetization to assess magnetic behavior and compare with millimeter wave data. Consistency of saturation magnetization determined independently by both millimeter wave absorption and DC magnetization have been found for all La-Co substituted barium hexaferrites. These materials seem to be quite promising as tunable millimeter wave absorbers, filters, circulators, based on the adjusting of their substitution parameters.