Sample records for continuous pneumatic nebulization

  1. A comparison of continuous pneumatic nebulization and flow injection-direct injection nebulization for sample introduction in inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Crain, J.S.; Kiely, J.T.

    1995-08-01

    Dilute nitric acid blanks and solutions containing Ni, Cd, Pb, and U (including two laboratory waste samples) were analyzed eighteen times over a two-month period using inductively coupled plasma-mass spectrometry (ICP-MS). Two different sample introduction techniques were employed: flow injection-direct injection nebulization (FI-DIN) and continuous pneumatic nebulization (CPN). Using comparable instrumental measurement procedures, FI-DIN analyses were 33% faster and generated 52% less waste than CPN analyses. Instrumental limits of detection obtained with FI-DIN and CPN were comparable but not equivalent (except in the case of Pb) because of nebulizer-related differences in sensitivity (i.e., signal per unit analyte concentration) and background. Substantial and statistically significant differences were found between FI-DIN and CPN Ni determinations, and in the case of the laboratory waste samples, there were also small but statistically significant differences between Cd determinations. These small (2 to 3%) differences were not related to polyatomic ion interference (e.g., 95 Mo 16 O + ), but in light of the time savings and waste reduction to be realized, they should not preclude the use of FI-DIN in place of CPN for determination of Cd, Pb, U and chemically

  2. Pneumatically Modulated Liquid Delivery System for Nebulizers

    Science.gov (United States)

    2011-12-02

    passing a high-velocity sheath gas over the orifice of a liquid filled capillary. Due to the Venturi effect , liquid is pulled from the capillary orifice... pump , or through self-aspiration. Each nebulizer is calibrated to a specific gas flow for self-aspiration, eliminating the need for an external pump ...the components in a single box. Flow rates with less than 0.5% relative standard deviation are possible, and results are compared with a syringe pump

  3. Multielement detection limits and sample nebulization efficiencies of an improved ultrasonic nebulizer and a conventional pneumatic nebulizer in inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Olson, K.W.; Haas, W.J. Jr.; Fassel, V.A.

    1977-01-01

    Two important aspects of the analytical performance of a newly developed ultrasonic nebulizer and a specially designed pneumatic nebulizer have been compared for use in inductively coupled plasma--atomic emission spectroscopy (ICP-AES). The ultrasonic nebulizer, when combined with a conventional aerosol desolvation apparatus, provided an order of magnitude or more improvement in simultaneous multielement detection limits as compared to those obtained when the pneumatic nebulizer was used either with or without desolvation. Application of a novel method for direct measurement of the overall efficiency of nebulization to the two systems showed that an approximately tenfold greater rate of sample delivery to the plasma torch was primarily responsible for the superior detection limits afforded by the ultrasonic nebulizer. A unique feature of the ultrasonic nebulizer described is the protection against chemical attack which is achieved by completely enclosing the transducer in an acoustically coupled borosilicate glass cylinder. Direct sample introduction, convenient sample change, and rapid cleanout are other important characteristics of the system which make it an attractive alternate to pneumatic nebulizer systems

  4. Simulation-based design of a microfabricated pneumatic electrospray nebulizer

    Czech Academy of Sciences Publication Activity Database

    Járvás, G.; Grym, Jakub; Foret, František; Guttman, A.

    2015-01-01

    Roč. 36, č. 3 (2015), s. 386-392 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GBP206/12/G014 Institutional support: RVO:68081715 Keywords : CFD * microfabrication * modeling * electrospray * nebulizer Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.482, year: 2015

  5. Simulation-based design of a microfabricated pneumatic electrospray nebulizer

    Czech Academy of Sciences Publication Activity Database

    Járvás, G.; Grym, Jakub; Foret, František; Guttman, A.

    2015-01-01

    Roč. 36, č. 3 (2015), s. 386-392 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GBP206/12/G014 Institutional support: RVO:68081715 Keywords : CFD * microfabrication * modeling * electrospray * nebulizer Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 2.482, year: 2015

  6. Comparison of the samples injection systems with ultrasonic nebulizer and with pneumatic nebulizer for the metal determination in water by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Marin, Sergio R; Pismante, Paola A

    2005-01-01

    The natural waters, depending on their use, must fulfill the exigencies and requirements that fix national and international norms. These establish conditions with respect to the concentration levels that must be some metals. In this work the development of inductively coupled plasma emission optical spectrometry with ultrasonic injection system is presented. The determination of aluminum, arsenic, barium, cadmium, zinc, cobalt, chromium, copper, iron, manganese, molybdenum, nickel, lead, strontium and vanadium, at levels of ultra-trace in water samples is studied by this technique. The wavelengths that represented better sensitivity and minors spectral interferences, were selected from the Literature specialized in the analysis of this type of material. Also the conditions of work for the ultrasonic nebulization: temperature, pressure, flow speed of argon, and flow speed of sample was determined. The greater sensitivity of the injection system by ultrasonic nebulization forehead to the injection system by pneumatic nebulization, is verified when comparing the spectral intensity of the selected wavelengths. Also the limits of detection and quantification was obtained by both systems. The validity of the results obtained in this method is verified applying the test of Fisher, who determines the degree of homogeneity of the variances, and the test of Student, to determine the trazability obtained with these values. For these studies, the certified material of reference TM-24.2 of National Water Research Institute Environment Canada (NWRI), was used. The positive answer to the criteria of evaluation E and Z-Score, obtained by this technique, allows to verify that it fulfills the exigencies to be used in the determination of metals at the required levels (au)

  7. Pneumatic Muscle Actuated Equipment for Continuous Passive Motion

    Science.gov (United States)

    Deaconescu, Tudor T.; Deaconescu, Andrea I.

    2009-10-01

    Applying continuous passive rehabilitation movements as part of the recovery programme of patients with post-traumatic disabilities of the bearing joints of the inferior limbs requires the development of new high performance equipment. This chapter discusses a study of the kinematics and performance of such a new, continuous passive motion based rehabilitation system actuated by pneumatic muscles. The utilized energy source is compressed air ensuring complete absorption of the end of stroke shocks, thus minimizing user discomfort.

  8. In vitro evaluation of aerosol delivery by different nebulization modes in pediatric and adult mechanical ventilators.

    Science.gov (United States)

    Wan, Gwo-Hwa; Lin, Hui-Ling; Fink, James B; Chen, Yen-Hey; Wang, Wei-Jhen; Chiu, Yu-Chun; Kao, Yu-Yao; Liu, Chia-Jung

    2014-10-01

    Aerosol delivery through mechanical ventilation is influenced by the type of aerosol generator, pattern of nebulization, and a patient's breathing pattern. This study compares the efficiency of pneumatic nebulization modes provided by a ventilator with adult and pediatric in vitro lung models. Three pneumatic nebulization modes (inspiratory intermittent [IIM], continuous [CM], and expiratory intermittent [EIM]) provided by the Galileo Gold ventilator delivered medical aerosol to collection filters distal to an endotracheal tube with adult and pediatric test lungs. A unit dose of 5 mg/2.5 mL albuterol was diluted into 4 mL with distilled water and added to a jet nebulizer. The nebulizer was placed proximal to the ventilator, 15 cm from the inlet of the heated humidifier chamber with a T-piece and corrugated aerosol tubing and powered by gas from the ventilator in each of the 3 modes. Time for nebulization was recorded in minutes. Albuterol samples collected in the inhalation filter, nebulizer, T-piece, and corrugated tubing were eluted with distilled water and analyzed with a spectrophotometer. The inhaled drug, as a percentage of total dose in both lung models, was 5.1-7.5%, without statistical significance among the 3 modes. Median nebulization times for IIM, CM, and EIM were 38.9, 14.3, and 17.7 min, respectively, and nebulization time for the 3 modes significantly differed (P ventilator was not dependent on nebulization mode during simulated pediatric and adult conventional mechanical ventilation. Use of expiratory intermittent mode and continuous nebulization should be considered to reduce treatment time. Copyright © 2014 by Daedalus Enterprises.

  9. Investigations on the use of pneumatic cross-flow nebulizers with dual solution loading including the correction of matrix effects in elemental determinations by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Bauer, Mathieu; Broekaert, Jose A.C.

    2007-01-01

    The use of a so-called trihedral and a T-shaped cross-flow pneumatic nebulizer with dual solution loading for inductively coupled plasma optical emission spectrometry has been studied. By these devices analyte clouds from two solutions can be mixed during the aerosol generation step. For both nebulizers the correction of matrix effects using internal standardization and standard addition calibration in an on-line way was investigated and compared to elemental determinations using a conventional cross-flow nebulizer and calibration with synthetic standard solutions without matrix matching. A significant improvement of accuracy, both for calibration with internal standardization and standard addition, was obtained in the case of four synthetic solutions containing each 40 mmol L -1 Na, K, Rb and Ba as matrix elements and 300 μg L -1 Cd, Co, Cr, Cu, Fe, Mn, Ni and Pb as analytes. Calibration by standard addition in the case of dual solution loading has been shown to be very useful in the determination of elements at minor and trace levels in steel and alumina reference materials. The results of analysis for minor concentrations of Cr, Cu and Ni in steel as well as for Ca, Fe, Ga, Li, Mg, Mn, Na, Si and Zn in alumina powder certified reference materials subsequent to sample dissolution were found to be in good agreement with the certificates. Limits of detection were found to be only slightly above those for a conventional cross-flow nebulizer and a precision better than 3% was realized with both novel nebulizers

  10. High efficiency nebulization for helium inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Jorabchi, Kaveh; McCormick, Ryan; Levine, Jonathan A.; Liu Huiying; Nam, S.-H.; Montaser, Akbar

    2006-01-01

    A pneumatically-driven, high efficiency nebulizer is explored for helium inductively coupled plasma mass spectrometry. The aerosol characteristics and analyte transport efficiencies of the high efficiency nebulizer for nebulization with helium are measured and compared to the results obtained with argon. Analytical performance indices of the helium inductively coupled plasma mass spectrometry are evaluated in terms of detection limits and precision. The helium inductively coupled plasma mass spectrometry detection limits obtained with the high efficiency nebulizer at 200 μL/min are higher than those achieved with the ultrasonic nebulizer consuming 2 mL/min solution, however, precision is generally better with high efficiency nebulizer (1-4% vs. 3-8% with ultrasonic nebulizer). Detection limits with the high efficiency nebulizer at 200 μL/min solution uptake rate approach those using ultrasonic nebulizer upon efficient desolvation with a heated spray chamber followed by a Peltier-cooled multipass condenser

  11. Experimental Study of Paddy Grain Drying in Continuous Recirculation System Pneumatic Conveyor

    Directory of Open Access Journals (Sweden)

    Prasetyo Totok

    2018-01-01

    Full Text Available Nowadays, paddy drying using conventional method is irrelevant to used. The increasing need of grain each year is one of the main factor that pushes scientist to invent new methods of drying paddy grain. The old method is unusefull since it takes up space, needed the sun as the drying media which causes a long drying time. One of the alternative of drying paddy grain is by using mechanic dryer. By using this dryer type, the process of drying takes faster comparing to the old method and the distribution of grain is supplied continuously. The dryer which uses pneumatic conveyor can be one of the solution due to its less energy consumption, a better drying result, and high drying capacity. The variable used to identify drying performance is temperature and loading weight. From the experiment, it is resulted that the best temperature for drying paddy grain is 60°C with the weight loading of 150 gram.

  12. 21 CFR 868.5640 - Medicinal nonventilatory nebulizer (atomizer).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medicinal nonventilatory nebulizer (atomizer). 868... SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5640 Medicinal nonventilatory nebulizer (atomizer). (a) Identification. A medicinal nonventilatory nebulizer (atomizer) is a...

  13. Effects of Nebulizer Position, Gas Flow, and CPAP on Aerosol Bronchodilator Delivery: An In Vitro Study.

    Science.gov (United States)

    Ball, Lorenzo; Sutherasan, Yuda; Caratto, Valentina; Sanguineti, Elisa; Marsili, Maria; Raimondo, Pasquale; Ferretti, Maurizio; Kacmarek, Robert M; Pelosi, Paolo

    2016-03-01

    The aim of this study was to investigate the effects of different delivery circuit configurations, nebulizer positions, CPAP levels, and gas flow on the amount of aerosol bronchodilator delivered during simulated spontaneous breathing in an in vitro model. A pneumatic lung simulator was connected to 5 different circuits for aerosol delivery, 2 delivering CPAP through a high-flow generator tested at 30, 60, and 90 L/min supplementary flow and 5, 10, and 15 cm H2O CPAP and 3 with no CPAP: a T-piece configuration with one extremity closed with a cap, a T-piece configuration without cap and nebulizer positioned proximally, and a T-piece configuration without cap and nebulizer positioned distally. Albuterol was collected with a filter, and the percentage amount delivered was measured by infrared spectrophotometry. Configurations with continuous high-flow CPAP delivered higher percentage amounts of albuterol compared with the configurations without CPAP (9.1 ± 6.0% vs 6.2 ± 2.8%, P = .03). Among configurations without CPAP, the best performance was obtained with a T-piece with one extremity closed with a cap. In CPAP configurations, the highest delivery (13.8 ± 4.4%) was obtained with the nebulizer placed proximal to the lung simulator, independent of flow. CPAP at 15 cm H2O resulted in the highest albuterol delivery (P = .02). Based on our in vitro study, without CPAP, a T-piece with a cap at one extremity maximizes albuterol delivery. During high-flow CPAP, the nebulizer should always be placed proximal to the patient, after the T-piece, using the highest CPAP clinically indicated. Copyright © 2016 by Daedalus Enterprises.

  14. Feedback mechanism for smart nozzles and nebulizers

    Science.gov (United States)

    Montaser, Akbar [Potomac, MD; Jorabchi, Kaveh [Arlington, VA; Kahen, Kaveh [Kleinburg, CA

    2009-01-27

    Nozzles and nebulizers able to produce aerosol with optimum and reproducible quality based on feedback information obtained using laser imaging techniques. Two laser-based imaging techniques based on particle image velocimetry (PTV) and optical patternation map and contrast size and velocity distributions for indirect and direct pneumatic nebulizations in plasma spectrometry. Two pulses from thin laser sheet with known time difference illuminate droplets flow field. Charge coupled device (CCL)) captures scattering of laser light from droplets, providing two instantaneous particle images. Pointwise cross-correlation of corresponding images yields two-dimensional velocity map of aerosol velocity field. For droplet size distribution studies, solution is doped with fluorescent dye and both laser induced florescence (LIF) and Mie scattering images are captured simultaneously by two CCDs with the same field of view. Ratio of LIF/Mie images provides relative droplet size information, then scaled by point calibration method via phase Doppler particle analyzer.

  15. Apparatus for ultrasonic nebulization

    International Nuclear Information System (INIS)

    Olson, K.W.; Haas, W.J. Jr.; Fassel, V.A.

    1978-01-01

    An improved apparatus is described for ultrasonic nebulization of liquid samples or suspensions in which the piezoelectric transducer is protected from chemical attack and erosion. The transducer is protected by being bonded to the inner surface of a glass plate which forms one end wall of a first hollow body provided with apparatus for circulating a fluid for cooling and stabilizing the transducer. The glass plate, which is one-half wavelength in thickness to provide an acoustically coupled outer nebulizing surface, seals an opening in a second hollow body which encloses an aerosol mixing chamber. The second body includes apparatus for delivering the sample solution to the nebulizing surface, a gas inlet for providing a flow of carrier gas for transporting the aerosol of the nebulized sample and an aerosol outlet

  16. Nebulized therapy. SEPAR year.

    Science.gov (United States)

    Olveira, Casilda; Muñoz, Ana; Domenech, Adolfo

    2014-12-01

    Inhaled drugs are deposited directly in the respiratory tract. They therefore achieve higher concentrations with faster onset of action and fewer side effects than when used systemically. Nebulized drugs are mainly recommended for patients that require high doses of bronchodilators, when they need to inhale drugs that only exist in this form (antibiotics or dornase alfa) or when they are unable to use other inhalation devices. Technological development in recent years has led to new devices that optimize pulmonary deposits and reduce the time needed for treatment. In this review we focus solely on drugs currently used, or under investigation, for nebulization in adult patients; basically bronchodilators, inhaled steroids, antibiotics, antifungals, mucolytics and others such as anticoagulants, prostanoids and lidocaine. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  17. Direct solution introduction using conventional nebulizers with a short torch for plasma mass spectrometry

    International Nuclear Information System (INIS)

    Westphal, Craig S.; Montaser, Akbar

    2006-01-01

    A new torch, a shortened version of a standard demountable torch, is proposed for facilitating direct injection of liquid samples into an inductively coupled plasma mass spectrometer using conventional and micro-pneumatic nebulizers. The proposed arrangement reduces the cost of the direct injector nebulizer by a factor of 5, typically from $2000 to $400, although a different torch is required. The analytical performance of the high efficiency nebulizer-short torch arrangement is compared to that obtained with the direct injection high efficiency nebulizer interfaced to the conventional torch. Optimum operating conditions for the high efficiency nebulizer-short torch arrangement are generally similar to those of the direct injection high efficiency nebulizer: high RF power (1500 W), low nebulizer gas flow rates (0.09 L/min) and low solution uptake rates (5-85 μL/min). Sensitivity with the high efficiency nebulizer-short torch system at 85 μL/min is improved by a factor of 2.4 on average compared to the direct injection high efficiency nebulizer, while precision values (%RSD) and detection limits are generally comparable or slightly degraded (on average by a factor of 1.7), respectively. Sensitivity is also better at lower solution uptake rates (5 μL/min) by factors ranging from 2 ( 82 Se) to 7 ( 59 Co) compared to the direct injection high efficiency nebulizer. Additionally, the %RSD values are better at 5 μL/min, ranging from 3.5% to 6.0% for the high efficiency nebulizer-short torch combination compared to 4.7 to 9.1% for the direct injection high efficiency nebulizer. The utility of the high efficiency nebulizer-short torch arrangement is demonstrated through the microscale flow injection analysis of Cr-DNA adducts and the analysis of four certified reference materials (Lyphochek urine metals control, SRM 1515: Apple Leaves, SRM 1570a: Spinach Leaves, SRM 1577b: Bovine Liver). Peak to peak precision values (N = 3) for the microscale flow injection analysis

  18. Pneumatic control technology

    International Nuclear Information System (INIS)

    Tae, Seong Gil; Kim, Won Hoe; Nam, Dae Hyun

    1993-03-01

    This book contains property of pneumatic pressure drive, pneumatic pressure device like air cleaning, pressure control, lubricators, air pressure pipe, kinds and function of pneumatic pressure equipment like pneumatic cylinders, pneumatic motor, flow control valve, direction control valve, design of pneumatic control circuit, pneumatic system design, cause and measurement of pneumatic circuit failure, PLC and pneumatic control like introduction and system application and method of PLC programing.

  19. Practical pneumatics

    CERN Document Server

    Stacey, Chris

    2012-01-01

    Pneumatic power is ideal for the ever increasing range of 'light' applications in which a cheap, clean, adaptable source of power is needed. Used in conjunction with microprocessor control it forms the basis of manufacturing automation from basic conveying and handling lines to complex robotic assembly systems. Training courses and books aimed at the technician have not kept pace with these developments. This book is written to cover the British Fluid Power Association Pneumatics Certificate, which is also awarded as part of CGLI scheme 2340, and is in the process of NVQ accreditation at level

  20. Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation

    DEFF Research Database (Denmark)

    Bendahl, Lars; Gammelgaard, Bente; Jons, O.

    2001-01-01

    A demountable direct injection high efficiency nebulizer operating at low sample uptake rates was developed and used for coupling of capillary electrophoresis (CE) with inductively coupled plasma mass spectrometry (ICP-MS). When the nebulizer was used for continuous sample introduction, detection...

  1. COPD -- how to use a nebulizer

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000699.htm COPD - how to use a nebulizer To use the ... page, please enable JavaScript. A nebulizer turns your COPD medicine into a mist. It is easier to ...

  2. Nebulized magnesium sulphate versus nebulized salbutamol in acute bronchial asthma

    Directory of Open Access Journals (Sweden)

    E.A. Abdelnabi

    2012-07-01

    Conclusion: The use of MgSO4 by nebulization in patients with acute asthma attacks results in improvement of clinical condition, increase in peak expiratory flow rate (PEFR, reduction in heart rate (HR, reduction in respiratory rate (RR and improvement in oxygen saturation (SO2. The increase in PEFR (bronchodilatory effect was significantly less than that achieved in patients receiving the usual treatment with Short acting β2 agonists, e.g. salbutamol, when either agents were used alone.

  3. Continuing versus discontinuing antiplatelet drugs, vasodilators, and/or cerebral ameliorators on perioperative total blood loss in total knee arthroplasty without pneumatic tourniquet

    Directory of Open Access Journals (Sweden)

    Sachiyuki Tsukada, MD

    2018-03-01

    Full Text Available Background: Although studies have supported the utility of perioperative continuation of antiplatelet drugs, vasodilators, and cerebral ameliorators in most procedures, no study compared total volume of blood loss after total knee arthroplasty (TKA in patients continuing and discontinuing these drugs. Methods: We retrospectively reviewed 266 consecutive patients undergoing TKA, and included 67 patients (25.2% taking antiplatelet drugs, vasodilators, or cerebral ameliorators in this study. All TKAs were performed without a pneumatic tourniquet. The primary outcome was perioperative total blood loss calculated from blood volume and change in hemoglobin. As subgroup analysis, we compared perioperative total blood loss in patients taking antiplatelet drugs. Results: There was no significant difference between the continuing group (n = 38 and discontinuing group (n = 29 in terms of the perioperative total blood loss (1025 ± 364 vs 1151 ± 327 mL, respectively; mean difference 126 mL; 95% confidence interval −45 to 298 mL; P = .15. No major bleeding or thrombotic events occurred in either group until postoperative 3-month follow-up. In patients taking antiplatelet drugs (n = 51, no significant difference was observed in the total blood loss between the continuing group (n = 30 and discontinuing group (n = 21 (1056 ± 287 vs 1151 ± 305 mL, respectively; mean difference 95 mL; 95% confidence interval −75 to 264 mL; P = .27. Conclusions: No significant differences in terms of perioperative total blood loss were observed between patients continuing and discontinuing study drugs. Continuing these drugs may be preferable in the perioperative period of TKA. Keywords: Knee, Primary arthroplasty, Bleeding events, Thrombotic events, Noncardiac surgery

  4. Electrostatic charge characteristics of jet nebulized aerosols.

    Science.gov (United States)

    Kwok, Philip Chi Lip; Trietsch, Sebastiaan J; Kumon, Michiko; Chan, Hak-Kim

    2010-06-01

    Liquid droplets can be spontaneously charged in the absence of applied electric fields by spraying. It has been shown by computational simulation that charges may influence particle deposition in the airways. The electrostatic properties of jet nebulized aerosols and their potential effects on lung deposition have hardly been studied. A modified electrical low pressure impactor (ELPI) was employed to characterize the aerosol charges generated from jet nebulized commercial products. The charge and size measurements were conducted at 50% RH and 22 degrees C with a modified ELPI. Ventolin, Bricanyl, and Atrovent were nebulized using PARI LC Plus jet nebulizers coupled to a DeVilbiss Pulmo-Aide compressor. The aerosols were sampled in 30-sec durations. The drug deposits on the impactor stages were assayed chemically using high-performance liquid chromatography (HPLC). The charges of nebulized deionized water, isotonic saline, and the three commercial products diluted with saline were also measured to analyze the contributions of the major nebule ingredients on charging. No mass assays were performed on these runs. All three commercial nebules generated net negative charges. The magnitude of the charges reduced over the period of nebulization. Ventolin and Bricanyl yielded similar charge profiles. Highly variable charges were produced from deionized water. On the other hand, nebulized saline reproducibly generated net positive charges. Diluted commercial nebules showed charge polarity inversion. The charge profiles of diluted salbutamol and terbutaline solutions resembled those of saline, while the charges from diluted ipratropium solutions fluctuated near neutrality. The charge profiles were shown to be influenced by the concentration and physicochemical properties of the drugs, as well as the history of nebulization. The drugs may have unique isoelectric concentrations in saline at which the nebulized droplets would carry near-zero charges. According to results from

  5. Nebulized hypertonic saline via positive expiratory pressure versus via jet nebulizer in patients with severe cystic fibrosis.

    LENUS (Irish Health Repository)

    O'Connell, Oisin J

    2011-06-01

    Nebulized hypertonic saline is a highly effective therapy for patients with cystic fibrosis (CF), yet 10% of patients are intolerant of hypertonic saline administered via jet nebulizer. Positive expiratory pressure (PEP) nebulizers splint open the airways and offers a more controlled rate of nebulization.

  6. Linear pneumatic actuator

    Directory of Open Access Journals (Sweden)

    Avram Mihai

    2017-01-01

    Full Text Available The paper presents a linear pneumatic actuator with short working stroke. It consists of a pneumatic motor (a simple stroke cylinder or a membrane chamber, two 2/2 pneumatic distributors “all or nothing” electrically commanded for controlling the intake/outtake flow to/from the active chamber of the motor, a position transducer and a microcontroller. There is also presented the theoretical analysis (mathematical modelling and numerical simulation accomplished.

  7. Linear pneumatic actuator

    OpenAIRE

    Avram Mihai; Niţu Constantin; Bucşan Constantin; Grămescu Bogdan

    2017-01-01

    The paper presents a linear pneumatic actuator with short working stroke. It consists of a pneumatic motor (a simple stroke cylinder or a membrane chamber), two 2/2 pneumatic distributors “all or nothing” electrically commanded for controlling the intake/outtake flow to/from the active chamber of the motor, a position transducer and a microcontroller. There is also presented the theoretical analysis (mathematical modelling and numerical simulation) accomplished.

  8. Laser-cutting pneumatics

    OpenAIRE

    Groenhuis, Vincent; Stramigioli, Stefano

    2016-01-01

    Pneumatic devices require tight tolerances to keep them leak-free. Specialized companies offer various off-the-shelf devices, while these work well for many applications, there are also situations where custom design and production of pneumatic parts are desired. Cost efficiency, design flexibility, rapid prototyping, and MRI compatibility requirements are reasons why we investigated a method to design and produce different pneumatic devices using a laser cutter from acrylic, acetal, and rubb...

  9. Lactic acidosis and diastolic hypotension after intermittent albuterol nebulization in a pediatric patient

    Directory of Open Access Journals (Sweden)

    Tehila A. Saadia

    2015-01-01

    Full Text Available We describe a case of 13-year-old female with intermittent asthma who developed lactic acidosis and diastolic hypotension after receiving intermittent albuterol nebulizer treatment. She presented to the emergency department (ED with sudden onset of shortness of breath and chest pain. She received two albuterol nebulizer treatments at home without symptomatic relief. She was treated in the ED with intermittent albuterol nebulization for a total of 22.5 mg over the next 5 hours. A decrease in diastolic blood pressure from 60 mmHg to 40 mmHg was noted after the treatment. Blood lactate level was 5.9 mmol/L. She recovered from it and was discharged to home but she had recurrence of shortness of breath and presented to the ED two days later. She was treated with albuterol nebulization for a total of 17.5 mg over the next two and half hours and developed diastolic hypotension again, as low as 30 mm Hg. After discontinuation of albuterol nebulization, her BP normalized. Cardiopulmonary and metabolic side effects of continuous albuterol therapy have been reported in the recent medical literature. Our patient, however, developed these adverse effects on intermittent albuterol nebulizer treatment. It is important for the pediatrician to recognize the adverse effects of β2-agonist therapy to avoid carrying out extensive workup for hypotension and hyperlactatemia prolonging hospital stay.

  10. Pneumatic and hydraulic microactuators: a review

    International Nuclear Information System (INIS)

    De Volder, Michaël; Reynaerts, Dominiek

    2010-01-01

    The development of MEMS actuators is rapidly evolving and continuously new progress in terms of efficiency, power and force output is reported. Pneumatic and hydraulic are an interesting class of microactuators that are easily overlooked. Despite the 20 years of research, and hundreds of publications on this topic, these actuators are only popular in microfluidic systems. In other MEMS applications, pneumatic and hydraulic actuators are rare in comparison with electrostatic, thermal or piezo-electric actuators. However, several studies have shown that hydraulic and pneumatic actuators deliver among the highest force and power densities at microscale. It is believed that this asset is particularly important in modern industrial and medical microsystems, and therefore, pneumatic and hydraulic actuators could start playing an increasingly important role. This paper shows an in-depth overview of the developments in this field ranging from the classic inflatable membrane actuators to more complex piston–cylinder and drag-based microdevices. (topical review)

  11. Chemical breakdown of radioaerosols during nebulization

    International Nuclear Information System (INIS)

    Waldman, D.L.; Weber, D.A.; Oberdrster, G.; Drago, S.R.; Utell, M.S.; Hyde, R.W.; Morrow, P.E.

    1985-01-01

    The diagnostic utility of radioaerosols for lung ventilation and lung permeability procedures requires a strong, stable coordinate covalent bond between a radionuclide and a ligand. The stability of the radiopharmaceutical before and after nebulization and hence its molecular size, are an absolute prerequisite for the method to be reproducible. To examine the possible effects of aerosolization on radiopharmaceuticals used for pulmonary imaging, the authors examined the radiochemical purity of Tc-99m DTPA following ultrasonic nebulization, jet nebulization (Dautrebande D-31), and inhalation with subsequent appearance in plasma and urine of dogs. Paper and liquid chromatographic methods were applied to determine radiochemical purity. Chromatographic assays showed a binding efficiency of less than 50% for ultrasonicly aerosolized Tc-99m DTPA. Cooling of the ultrasonic coupling fluid increased the binding efficiency to greater than 95% following nebulization and inhalation. Jet nebulization did not affect the radiochemical purity of the radiopharmaceutical. Ultrasonic nebulization will partially destroy the Tc-99m DTPA complex; cooling the ultrasonic connecting fluid and constant aerosol monitoring are required for consistent, reproducible results

  12. Rotary pneumatic valve

    Science.gov (United States)

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  13. Laser-cutting pneumatics

    NARCIS (Netherlands)

    Groenhuis, Vincent; Stramigioli, Stefano

    Pneumatic devices require tight tolerances to keep them leak-free. Specialized companies offer various off-the-shelf devices, while these work well for many applications, there are also situations where custom design and production of pneumatic parts are desired. Cost efficiency, design flexibility,

  14. Pneumatic conveying design guide

    CERN Document Server

    Mills, David

    1990-01-01

    Pneumatic Conveying Design Guide is a guide for the design of pneumatic conveying systems and includes detailed data and information on the conveying characteristics of a number of materials with a wide range of properties. This book includes logic diagrams for design procedures and scaling parameters for the conveying line configuration. It also explains how to improve the performance of pneumatic conveyors by optimizing, uprating, and extending the system or adapting it for a change of material. This book consists of 15 chapters divided into three sections and opens with an overview of the s

  15. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Science.gov (United States)

    2010-10-01

    ... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... exposed in the space. (c) A pneumatic fire detection system must be set to activate after approximately a...

  16. Pneumatic Muscle Actuator Control

    National Research Council Canada - National Science Library

    Lilly, John

    2000-01-01

    This research is relevant to the Air Fore mission because pneumatic muscle actuation devices arc advantageous for certain types of robotics as well as for strength and/or mobility assistance for humans...

  17. Pneumatic transfer systems

    International Nuclear Information System (INIS)

    Bichler, H.; Boeck, H.; Hammer, J.; Buchtela, K.

    1988-11-01

    A pneumatic transfer system for research reactors, including a sample changer system and to be used for neutron activation analysis, is described. The system can be obtained commercially from the Atominstitut. 2 figs. (qui)

  18. Impact of constant and breath-synchronized nebulization on inhaled mass of nebulized budesonide in infants and children

    DEFF Research Database (Denmark)

    Nikander, K; Bisgaard, H

    1999-01-01

    The aim of the present study was to compare the output of a breath-synchronized jet nebulizer to a conventional constant output nebulizer over a fixed period of time in terms of inhaled mass of budesonide, i.e., the amount of budesonide deposited on a filter interposed between the nebulizer and t...... resulted in reduced waste of drug during expiration....

  19. The function profile of compressed-air and ultrasonic nebulizers.

    Science.gov (United States)

    Wu, Hsin-Lin; Lin, Yung-Zen; Wu, Wei-Fong; Huang, Fu-Yuan

    2003-01-01

    In order to study the detailed function of two kinds of nebulizers commonly used in clinical asthma treatment, compressed-air and ultrasonic, this study was conducted. At the beginning, various flow rates were adjusted, paired with different volumes of solutions in the container. The changes of temperature, pH, and osmolality during the course of nebulization were examined. Normal saline, terbutaline, and fenoterol solutions were used as the nebulized solutions. The study was performed in an environment in ambient temperature around 20 degrees C and relative humidity around 70%. The results showed a minimal 6 L/min flow rate was required to nebulize the solution when using the compressed-air nebulizer. The dead volume was about 0.8 ml for compressed-air and 8.5 ml for the ultrasonic nebulizer. When using the compressed-air nebulizer, the temperature, both in the solution and at the mouthpiece site, dropped gradually. On the contrary, the temperatures at both sites increased a little bit when using the ultrasonic nebulizer. The pH values of pure terbutaline and fenoterol nebulized solutions were acidic (3.58 and 3.00 respectively). The osmolality of terbutaline and fenoterol nebulized solutions were isotonic. The osmolality increased gradually during the course of nebulization, to a greater extent in the compressed-air nebulizer. In conclusion, both types of nebulizers have their special features. The ultrasonic nebulizer displays less extent in change of temperature and osmolality during nebulization and is expected to be a better device in treating asthmatic patients in terms of lesser effect on cooling and changing the osmolality of airway mucosa.

  20. Residual gravimetric method to measure nebulizer output.

    Science.gov (United States)

    Vecellio None, Laurent; Grimbert, Daniel; Bordenave, Joelle; Benoit, Guy; Furet, Yves; Fauroux, Brigitte; Boissinot, Eric; De Monte, Michele; Lemarié, Etienne; Diot, Patrice

    2004-01-01

    The aim of this study was to assess a residual gravimetric method based on weighing dry filters to measure the aerosol output of nebulizers. This residual gravimetric method was compared to assay methods based on spectrophotometric measurement of terbutaline (Bricanyl, Astra Zeneca, France), high-performance liquid chromatography (HPLC) measurement of tobramycin (Tobi, Chiron, U.S.A.), and electrochemical measurements of NaF (as defined by the European standard). Two breath-enhanced jet nebulizers, one standard jet nebulizer, and one ultrasonic nebulizer were tested. Output produced by the residual gravimetric method was calculated by weighing the filters both before and after aerosol collection and by filter drying corrected by the proportion of drug contained in total solute mass. Output produced by the electrochemical, spectrophotometric, and HPLC methods was determined after assaying the drug extraction filter. The results demonstrated a strong correlation between the residual gravimetric method (x axis) and assay methods (y axis) in terms of drug mass output (y = 1.00 x -0.02, r(2) = 0.99, n = 27). We conclude that a residual gravimetric method based on dry filters, when validated for a particular agent, is an accurate way of measuring aerosol output.

  1. The relationship between presbycusis and mastoid pneumatization.

    Science.gov (United States)

    Pata, Yavuz Selim; Akbaş, Yucel; Unal, Murat; Duce, Meltem Nass; Akbaş, Tugana; Micozkadioğlu, Deniz

    2004-02-29

    Presbycusis is defined as the natural hearing loss accompanying aging, caused by degenerative changes in the inner ear. The etiology of presbycusis is uncertain. However, it would appear that a complex genetic cause is most likely. The determinants of mastoid size continue to be controversial. One of the pneumatization theories is the hereditary theory. In this study, the possible relationship between presbycusis and the extent of mastoid pneumatization was investigated. This study was carried out on 21 patients with presbycusis and 21 normal subjects of similar ages. The pneumatized volume was measured by computerized tomography. The temporal bone was scanned at 2 mm thickness intervals. Exposure (kV 130, mA105). The scan plane was parallel to the orbitomeatal line and the CT images covered the entire mastoid region. The average mastoid pneumatization in presbycusis group was 6.08 +/- 2.52 cm(3) in the right ear and 6.19 +/- 2.93 cm(3) in the left ear. However, in the control group it was 4.69 +/- 3.17 cm(3) in the right ear (p=0.12) and 5.10 +/- 3.49 cm(3) in the left ear (p=0.28). No significant difference was found between the presbycusis patients and normal subjects in terms of the volume of mastoid pneumatization.

  2. Comparison of numerical simulations to experiments for atomization in a jet nebulizer.

    Science.gov (United States)

    Lelong, Nicolas; Vecellio, Laurent; Sommer de Gélicourt, Yann; Tanguy, Christian; Diot, Patrice; Junqua-Moullet, Alexandra

    2013-01-01

    The development of jet nebulizers for medical purposes is an important challenge of aerosol therapy. The performance of a nebulizer is characterized by its output rate of droplets with a diameter under 5 µm. However the optimization of this parameter through experiments has reached a plateau. The purpose of this study is to design a numerical model simulating the nebulization process and to compare it with experimental data. Such a model could provide a better understanding of the atomization process and the parameters influencing the nebulizer output. A model based on the Updraft nebulizer (Hudson) was designed with ANSYS Workbench. Boundary conditions were set with experimental data then transient 3D calculations were run on a 4 µm mesh with ANSYS Fluent. Two air flow rate (2 L/min and 8 L/min, limits of the operating range) were considered to account for different turbulence regimes. Numerical and experimental results were compared according to phenomenology and droplet size. The behavior of the liquid was compared to images acquired through shadowgraphy with a CCD Camera. Three experimental methods, laser diffractometry, phase Doppler anemometry (PDA) and shadowgraphy were used to characterize the droplet size distributions. Camera images showed similar patterns as numerical results. Droplet sizes obtained numerically are overestimated in relation to PDA and diffractometry, which only consider spherical droplets. However, at both flow rates, size distributions extracted from numerical image processing were similar to distributions obtained from shadowgraphy image processing. The simulation then provides a good understanding and prediction of the phenomena involved in the fragmentation of droplets over 10 µm. The laws of dynamics apply to droplets down to 1 µm, so we can assume the continuity of the distribution and extrapolate the results for droplets between 1 and 10 µm. So, this model could help predicting nebulizer output with defined geometrical and

  3. Comparison of numerical simulations to experiments for atomization in a jet nebulizer.

    Directory of Open Access Journals (Sweden)

    Nicolas Lelong

    Full Text Available The development of jet nebulizers for medical purposes is an important challenge of aerosol therapy. The performance of a nebulizer is characterized by its output rate of droplets with a diameter under 5 µm. However the optimization of this parameter through experiments has reached a plateau. The purpose of this study is to design a numerical model simulating the nebulization process and to compare it with experimental data. Such a model could provide a better understanding of the atomization process and the parameters influencing the nebulizer output. A model based on the Updraft nebulizer (Hudson was designed with ANSYS Workbench. Boundary conditions were set with experimental data then transient 3D calculations were run on a 4 µm mesh with ANSYS Fluent. Two air flow rate (2 L/min and 8 L/min, limits of the operating range were considered to account for different turbulence regimes. Numerical and experimental results were compared according to phenomenology and droplet size. The behavior of the liquid was compared to images acquired through shadowgraphy with a CCD Camera. Three experimental methods, laser diffractometry, phase Doppler anemometry (PDA and shadowgraphy were used to characterize the droplet size distributions. Camera images showed similar patterns as numerical results. Droplet sizes obtained numerically are overestimated in relation to PDA and diffractometry, which only consider spherical droplets. However, at both flow rates, size distributions extracted from numerical image processing were similar to distributions obtained from shadowgraphy image processing. The simulation then provides a good understanding and prediction of the phenomena involved in the fragmentation of droplets over 10 µm. The laws of dynamics apply to droplets down to 1 µm, so we can assume the continuity of the distribution and extrapolate the results for droplets between 1 and 10 µm. So, this model could help predicting nebulizer output with defined

  4. Impact of humidification and nebulization during expiratory limb protection: an experimental bench study.

    Science.gov (United States)

    Tonnelier, Alexandre; Lellouche, François; Bouchard, Pierre Alexandre; L'Her, Erwan

    2013-08-01

    Different filtering devices are used during mechanical ventilation to avoid dysfunction of flow and pressure transducers or for airborne microorganisms containment. Water condensates, resulting from the use of humidifiers, but also residual nebulization particles may have a major influence on expiratory limb resistance. To evaluate the influence of nebulization and active humidification on the resistance of expiratory filters. A respiratory system analog was constructed using a test lung, an ICU ventilator, heated humidifiers, and a piezoelectric nebulizer. Humidifiers were connected to different types of circuits (unheated, mono-heated, new-generation and old-generation bi-heated). Five filter types were evaluated: electrostatic, heat-and-moisture exchanger, standard, specific, and internal heated high-efficiency particulate air [HEPA] filter. Baseline characteristics were obtained from each dry filter. Differential pressure measurements were carried out after 24 hours of continuous in vitro use for each condition, and after 24 hours of use with an old-generation bi-heated circuit without nebulization. While using unheated circuits, measurements had to be interrupted before 24 hours for all the filtering devices except the internal heated HEPA filter. The heat-and-moisture exchangers occluded before 24 hours with the unheated and mono-heated circuits. The circuit type, nebulization practice, and duration of use did not influence the internal heated HEPA filter resistance. Expiratory limb filtration is likely to induce several major adverse events. Expiratory filter resistance increase is due mainly to the humidification circuit type, rather than to nebulization. If filtration is mandatory while using an unheated circuit, a dedicated filter should be used for ≤ 24 hours, or a heated HEPA for a longer duration.

  5. Pneumatic soil removal tool

    International Nuclear Information System (INIS)

    Neuhaus, J.E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs

  6. Pneumatic soil removal tool

    Science.gov (United States)

    Neuhaus, John E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.

  7. Hydraulics and pneumatics

    CERN Document Server

    Parr, Andrew

    2006-01-01

    Nearly all industrial processes require objects to be moved, manipulated or subjected to some sort of force. This is frequently accomplished by means of electrical equipment (such as motors or solenoids), or via devices driven by air (pneumatics) or liquids (hydraulics).This book has been written by a process control engineer as a guide to the operation of hydraulic and pneumatic systems for all engineers and technicians who wish to have an insight into the components and operation of such a system.This second edition has been fully updated to include all recent developments su

  8. Multicentre randomised controlled trial to investigate the usefulness of continuous pneumatic regulation of tracheal cuff pressure for reducing ventilator-associated pneumonia in mechanically ventilated severe trauma patients: the AGATE study protocol.

    Science.gov (United States)

    Marjanovic, Nicolas; Frasca, Denis; Asehnoune, Karim; Paugam, Catherine; Lasocki, Sigismond; Ichai, Carole; Lefrant, Jean-Yves; Leone, Marc; Dahyot-Fizelier, Claire; Pottecher, Julien; Falcon, Dominique; Veber, Benoit; Constantin, Jean-Michel; Seguin, Sabrina; Guénézan, Jérémy; Mimoz, Olivier

    2017-08-07

    Severe trauma represents the leading cause of mortality worldwide. While 80% of deaths occur within the first 24 hours after trauma, 20% occur later and are mainly due to healthcare-associated infections, including ventilator-associated pneumonia (VAP). Preventing underinflation of the tracheal cuff is recommended to reduce microaspiration, which plays a major role in the pathogenesis of VAP. Automatic devices facilitate the regulation of tracheal cuff pressure, and their implementation has the potential to reduce VAP. The objective of this work is to determine whether continuous regulation of tracheal cuff pressure using a pneumatic device reduces the incidence of VAP compared with intermittent control in severe trauma patients. This multicentre randomised controlled and open-label trial will include patients suffering from severe trauma who are admitted within the first 24 hours, who require invasive mechanical ventilation to longer than 48 hours. Their tracheal cuff pressure will be monitored either once every 8 hours (control group) or continuously using a pneumatic device (intervention group). The primary end point is the proportion of patients that develop VAP in the intensive care unit (ICU) at day 28. The secondary end points include the proportion of patients that develop VAP in the ICU, early (≤7 days) or late (>7 days) VAP, time until the first VAP diagnosis, the number of ventilator-free days and antibiotic-free days, the length of stay in the ICU, the proportion of patients with ventilator-associated events and that die during their ICU stay. This protocol has been approved by the ethics committee of Poitiers University Hospital, and will be carried out according to the principles of the Declaration of Helsinki and the Good Clinical Practice guidelines. The results of this study will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals. Clinical Trials NCT02534974. © Article author(s) (or

  9. Pharmacokinetics of nebulized terbinafine in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Emery, Lee C; Cox, Sherry K; Souza, Marcy J

    2012-09-01

    Aspergillosis is one of the most difficult diseases to treat successfully in avian species. Terbinafine hydrochloride offers numerous potential benefits over traditionally used antifungals for treatment of this disease. Adding nebulized antifungals to treatment strategies is thought to improve clinical outcomes in lung diseases. To determine plasma concentrations of terbinafine after nebulization, 6 adult Hispaniolan Amazon parrots were randomly divided into 2 groups of 3. Each bird was nebulized for 15 minutes with 1 of 2 terbinafine solutions, one made with a crushed tablet and the second with raw drug powder. Blood samples were collected at baseline and at multiple time points up to 720 minutes after completing nebulization. Plasma and nebulization solutions were analyzed by high-performance liquid chromatography. The terbinafine concentration of the solution made with a crushed tablet (0.87 +/- 0.05 mg/mL) was significantly lower than was that made with raw powder (1.02 +/- 0.09 mg/mL). Plasma concentrations of terbinafine did not differ significantly between birds in the 2 groups. Plasma terbinafine concentrations in birds were maintained above in vitro minimum inhibitory concentrations for approximately 1 hour in birds nebulized with the crushed tablet solution and 4 hours in birds nebulized with the raw powder solution. Higher concentrations of solution, longer nebulization periods, or more frequent administration are likely needed to reach therapeutic plasma concentrations of terbinafine for clinically relevant periods in Hispaniolan Amazon parrots.

  10. TOPICAL REVIEW: Pneumatic and hydraulic microactuators: a review

    Science.gov (United States)

    De Volder, Michaël; Reynaerts, Dominiek

    2010-04-01

    The development of MEMS actuators is rapidly evolving and continuously new progress in terms of efficiency, power and force output is reported. Pneumatic and hydraulic are an interesting class of microactuators that are easily overlooked. Despite the 20 years of research, and hundreds of publications on this topic, these actuators are only popular in microfluidic systems. In other MEMS applications, pneumatic and hydraulic actuators are rare in comparison with electrostatic, thermal or piezo-electric actuators. However, several studies have shown that hydraulic and pneumatic actuators deliver among the highest force and power densities at microscale. It is believed that this asset is particularly important in modern industrial and medical microsystems, and therefore, pneumatic and hydraulic actuators could start playing an increasingly important role. This paper shows an in-depth overview of the developments in this field ranging from the classic inflatable membrane actuators to more complex piston-cylinder and drag-based microdevices.

  11. Nebulized corticosteroids in the management of acute exacerbation of COPD

    Directory of Open Access Journals (Sweden)

    Gaude G

    2010-01-01

    Full Text Available Acute exacerbations in chronic onstructive pulmonary disease (COPD are common and systemic steroids play an important role in the management of these cases along with the bronchodilators. Nebulized budesonide is being used in the acute attacks of bronchial asthma either in children or in adults. But the role of nebulized steroids in acute exacerbation of COPD is not much studied in the literature. In this clinical review we have evaluated the role of nebulized corticosteroids in the management of acute exacerbation of COPD (AECOPD. Through Medline, Pubmed and Embase we analyzed the various studies that has been done to study the role of nebulized corticosteroids in the management of acute exacerbation of COPD. The key words used for the search criteria were: acute exacerbation, COPD, nebulized corticosteroids, budesonide, fluticasone. Only eight studies were found which had evaluated the role of nebulized corticosteroids in acute exacerbations of COPD. All these studies had used nebulized budesonide in AECOPD in different dosages, and had been compared with both either parental or oral steroids, and standard bronchodilator therapy. All the studies had found the clinical efficacy of nebulized budesonide to be of similar extent to that of either parental or oral steroids in AECOPD. Side effects profile of nebulized budesonide was minimal and acceptable as compared to systemic steroids. Nebulized budesonide may be an alternative to parental/oral prednisolone in the treatment of acute exacerbations of COPD but further studies should be done to evaluate its long-term impact on clinical outcomes after an initial episode of COPD exacerbation.

  12. Rigidified pneumatic composites

    Science.gov (United States)

    van Dessel, Steven

    2000-10-01

    The overall objective of the research presented in this dissertation was to address global issues of adequate housing for all and the need for more sustainable human settlement. In order to address these, the emerging technology of rigidified pneumatic composites was investigated. Rigidified pneumatic composites (RPC) are defined as thin flexible membrane structures that are pneumatically deployed. After deployment, these structures harden due to chemical or physical change of the membrane. Because of this change, these structures do no longer require pneumatic pressure to maintain their shape. For the first time, a systematic listing of the various means available to develop polymeric materials useful in RPC technology is presented. With the aim to reduce the cost of RPC structures, a new material was proposed, developed, and evaluated. This material involved the formation of a semi-interpenetrating polymer network based on poly vinyl chloride and an acrylate based reactive plasticizer. The economical and environmental performances of RPC structures using this new material were assessed by means of a case study. In this study, the performance of RPC technology was compared with that of a typical wood light frame structure in the application of a small single-family house. The study indicated that the cost of ownership in present day value for the RPC structure was approximately 33% less than the cost of a comparable wood light frame structure. The study also indicated that significant environmental benefits exist with the use of RPC structures. It was found that the RPC structure used significantly less resources compared to the wood light frame structure. About 3.5 times less materials coming from non-renewable fossil resources, about 2.5 times less materials coming from trees, and about 19 times less materials coming from inorganic resources was used in the RPC structure relative to the wood light frame structure. The study concluded with pointing out various

  13. Immunological and physical properties of allergen solutions. Effects of nebulization

    DEFF Research Database (Denmark)

    Frølund, L; Poulsen, L K; Heinig, J H

    1991-01-01

    activity was measured by IgG4 RAST inhibition technique and allergen quality was analysed by crossed immunoelectrophoresis (CIE). The distribution of particle sizes of aerosols of different allergen solutions was determined by a TSI Aerodynamic Particle Sizer. A significant difference (P less than 0.......05) in allergen activity was found between the AD and H2O diluents before and after using a Sandoz nebulizer and a Wright nebulizer equipped with a small chamber. This suggested greater allergen activity in AD-diluted solutions, and the pattern was repeated with the other two nebulizers, but was not statistically...

  14. Soft, Rotating Pneumatic Actuator.

    Science.gov (United States)

    Ainla, Alar; Verma, Mohit S; Yang, Dian; Whitesides, George M

    2017-09-01

    This article describes a soft pneumatic actuator that generates cyclical motion. The actuator consists of several (three, four, or five) chambers (arranged around the circumference of a circle surrounding a central rod) that can be actuated independently using negative pressure (or partial vacuum). Sequential actuation of the four-chamber device using reduced pressure moves the central rod cyclically in an approximately square path. We characterize the trajectory of the actuator and the force exerted by it, as we vary the material used for fabrication, the number of chambers, and the size of the actuator. We demonstrate two applications of this actuator: to deliver fluid while stirring (by replacing the central rod with a needle) and for locomotion that mimics a reptilian gait (by combining four actuators together).

  15. Induced tolerance to nebulized colistin after severe reaction to the drug.

    Science.gov (United States)

    Domínguez-Ortega, J; Manteiga, E; Abad-Schilling, C; Juretzcke, M A; Sánchez-Rubio, J; Kindelan, C

    2007-01-01

    Daily nebulized colistin therapy has been used as maintenance therapy for patients with chronic Pseudomonas aeruginosa infection and in treatment protocols aimed at eradicating early P aeruginosa infection. Colistin-induced nephrotoxicity and mild neurotoxic effects have been described but hypersensitivity reactions are rare. However, bronchial constriction has been reported associated with the inhalation of the antibiotic. We report the case of a 63-year-old man who had been diagnosed with bronchiectasis and bronchopleural fistula and who developed severe bronchospasm when using nebulized colistin. A skin prick test (80 mg/mL) with colistin was performed and was negative. An intradermal test was not performed due to its possible irritant effect. As our patient suffered from a tobramycin-resistant P aeruginosa infection, we started a procedure to induce tolerance to 80 mg colistin (8 mg, 16 mg, 24 mg, 32 mg, 40 mg, 80 mg) nebulized in 30-minutes-intervals. No changes in forced expiratory volume in 1 second values were observed and the patient continues on treatment twice daily after the tolerance induction with no new episodes of bronchospasm. We report the first successful procedure to induce tolerance to colistin after escalating doses of inhaled colistin.

  16. Nebulized antibiotics in mechanically ventilated patients: roadmap and challenges.

    Science.gov (United States)

    Poulakou, G; Siakallis, G; Tsiodras, S; Arfaras-Melainis, A; Dimopoulos, G

    2017-03-01

    Nebulized antibiotics use has become common practice in the therapeutics of pneumonia in cystic fibrosis patients. There is an increasing interest in their use for respiratory infections in mechanically ventilated (MV) patients in order to a) overcome pharmacokinetic issues in the lung compartment with traditional systemic antibiotic use and b) prevent the emergence of multi-drug-resistant (MDR) pathogens. Areas covered: The beneficial effects of antibiotic nebulization in MV patients e.g. increasing efficacy, reduced toxicity and prevention of resistance are described. Physicochemical parameters of optimal lung deposition, characteristics of currently available nebulizers, practical aspects of the procedure, including drug preparation and adjustments of ventilator and circuit parameter are presented. Antibiotics used in nebulized route, along with efficacy in various clinical indications and safety issues are reviewed. Expert commentary: The safety of nebulization of antibiotics has been proven in numerous studies; efficacy as adjunctive treatment to intravenous regimens or as monotherapy has been demonstrated in ventilator-associated pneumonia or ventilator-associated tracheobronchitis due to MDR or susceptible pathogens. However, due to the heterogeneity of studies, multiple meta-analyses fail to demonstrate a clear effect. Clarification of indications, standardization of technique and implementation of clinical practice guidelines, based on new large-scale trials will lead to the optimal use of nebulized antibiotics.

  17. Soft Pneumatic Actuators for Rehabilitation

    Directory of Open Access Journals (Sweden)

    Guido Belforte

    2014-05-01

    Full Text Available Pneumatic artificial muscles are pneumatic devices with practical and various applications as common actuators. They, as human muscles, work in agonistic-antagonistic way, giving a traction force only when supplied by compressed air. The state of the art of soft pneumatic actuators is here analyzed: different models of pneumatic muscles are considered and evolution lines are presented. Then, the use of Pneumatic Muscles (PAM in rehabilitation apparatus is described and the general characteristics required in different applications are considered, analyzing the use of proper soft actuators with various technical properties. Therefore, research activity carried out in the Department of Mechanical and Aerospace Engineering in the field of soft and textile actuators is presented here. In particular, pneumatic textile muscles useful for active suits design are described. These components are made of a tubular structure, with an inner layer of latex coated with a deformable outer fabric sewn along the edge. In order to increase pneumatic muscles forces and contractions Braided Pneumatic Muscles are studied. In this paper, new prototypes are presented, based on a fabric construction and various kinds of geometry. Pressure-force-deformation tests results are carried out and analyzed. These actuators are useful for rehabilitation applications. In order to reproduce the whole upper limb movements, new kind of soft actuators are studied, based on the same principle of planar membranes deformation. As an example, the bellows muscle model and worm muscle model are developed and described. In both cases, wide deformations are expected. Another issue for soft actuators is the pressure therapy. Some textile sleeve prototypes developed for massage therapy on patients suffering of lymph edema are analyzed. Different types of fabric and assembly techniques have been tested. In general, these Pressure Soft Actuators are useful for upper/lower limbs treatments

  18. A new method for measuring aerosol nebulizers output using radioactive tracers

    International Nuclear Information System (INIS)

    Gatnash, A.A.; Connolly, C.K.; Chandler, S.T.

    1998-01-01

    Reproducibility and comparability of bronchial challenge tests depends critically on accurate assessment of nebulizers output. Evaporation during nebulization means that simple weighing is inaccurate, overestimating the delivered dose of active ingredient. We wanted to quantify this effect in the context of intermittent nebulization, using a dosimeter as used in bronchial provocation tests. Output of three types of nebulizers, from the MEFAR dosimeter, was measured by radioactive tracer, using a standard solution of technetium-99m-pertechnetate (1.5 kBq x mL -1 ) in 4 mL of normal saline. The aerosol was impacted by suction onto a micro filter, and the radioactivity measured. Nebulizers were weighed before and after nebulization. Ratio of nebulized volume calculated from the radioactivity on the filter, to the total volume loss by weight, was expressed as nebulized ratio. The effect on output of two concentrations of methacholine, two tracers of different weights, and change in temperature, were assessed. Nebulized ratio varied between 44.1-71.6%. Results were more consistent within the same type of nebulizer than between different makes. Neither changes in molar concentration nor molecular weight affected nebulizer output or nebulized ratio. Mean nebulized ratio was 58.5%, showing that calibration by weighing, overestimates the delivered dose by a factor of approximately two. Measuring radioactivity eluted from a micro filter, onto which nebulized output had been impacted proved to be a satisfactory method of calibration. (au)

  19. Development of repeating pneumatic pellet injector

    Energy Technology Data Exchange (ETDEWEB)

    Oda, Y.; Onozuka, M.; Shimomura, T. (Mitsubishi Heavy Industries Ltd., Kobe (Japan)) (and others)

    1990-01-01

    A repeating pneumatic pellet injector has been constructed to experiment with the technique of continuous injection for fueling fusion reactors. This device is composed of a cryogenic extruder and a gun assembly in (among others) a high-vacuum vessel, diagnostic vessels, LHe, fuel-gas and propellant-gas supply systems, control and data acquisition systems, etc. The performance tests, using hydrogen, have proved that the device provides the function of extruding frozen hydrogen ribbons at the speed of 6 mm s{sup -1}, chambering pellet at the rate of 5 Hz, and injecting pellet at the speed of 900 m s{sup -1}, as planned. (author).

  20. Development of repeating pneumatic pellet injector

    International Nuclear Information System (INIS)

    Oda, Y.; Onozuka, M.; Shimomura, T.

    1990-01-01

    A repeating pneumatic pellet injector has been constructed to experiment with the technique of continuous injection for fueling fusion reactors. This device is composed of a cryogenic extruder and a gun assembly in (among others) a high-vacuum vessel, diagnostic vessels, LHe, fuel-gas and propellant-gas supply systems, control and data acquisition systems, etc. The performance tests, using hydrogen, have proved that the device provides the function of extruding frozen hydrogen ribbons at the speed of 6 mm s -1 , chambering pellet at the rate of 5 Hz, and injecting pellet at the speed of 900 m s -1 , as planned. (author)

  1. Effect of mask dead space and occlusion of mask holes on delivery of nebulized albuterol.

    Science.gov (United States)

    Berlinski, Ariel

    2014-08-01

    Infants and children with respiratory conditions are often prescribed bronchodilators. Face masks are used to facilitate the administration of nebulized therapy in patients unable to use a mouthpiece. Masks incorporate holes into their design, and their occlusion during aerosol delivery has been a common practice. Masks are available in different sizes and different dead volumes. The aim of this study was to compare the effect of different degrees of occlusion of the mask holes and different mask dead space on the amount of nebulized albuterol available at the mouth opening in a model of a spontaneously breathing child. A breathing simulator mimicking infant (tidal volume [VT] = 50 mL, breathing frequency = 30 breaths/min, inspiratory-expiratory ratio [I:E] = 1:3), child (VT = 155 mL, breathing frequency = 25 breaths/min, I:E = 1:2), and adult (VT = 500 mL, breathing frequency = 15 breaths/min, I:E = 1:2) breathing patterns was connected to a collection filter hidden behind a face plate. A pediatric size mask and an adult size mask connected to a continuous output jet nebulizer were sealed to the face plate. Three nebulizers were loaded with albuterol sulfate (2.5 mg/3 mL) and operated with 6 L/min compressed air for 5 min. Experiments were repeated with different degrees of occlusion (0%, 50%, and 90%). Albuterol was extracted from the filter and measured with a spectrophotometer at 276 nm. Occlusion of the holes in the large mask did not increase the amount of albuterol in any of the breathing patterns. The amount of albuterol captured at the mouth opening did not change when the small mask was switched to the large mask, except with the breathing pattern of a child, and when the holes in the mask were 50% occluded (P = .02). Neither decreasing the dead space of the mask nor occluding the mask holes increased the amount of nebulized albuterol captured at the mouth opening.

  2. Anti-Tuberculosis Bacteriophage D29 Delivery with a Vibrating Mesh Nebulizer, Jet Nebulizer, and Soft Mist Inhaler.

    Science.gov (United States)

    Carrigy, Nicholas B; Chang, Rachel Y; Leung, Sharon S Y; Harrison, Melissa; Petrova, Zaritza; Pope, Welkin H; Hatfull, Graham F; Britton, Warwick J; Chan, Hak-Kim; Sauvageau, Dominic; Finlay, Warren H; Vehring, Reinhard

    2017-10-01

    To compare titer reduction and delivery rate of active anti-tuberculosis bacteriophage (phage) D29 with three inhalation devices. Phage D29 lysate was amplified to a titer of 11.8 ± 0.3 log 10 (pfu/mL) and diluted 1:100 in isotonic saline. Filters captured the aerosolized saline D29 preparation emitted from three types of inhalation devices: 1) vibrating mesh nebulizer; 2) jet nebulizer; 3) soft mist inhaler. Full-plate plaque assays, performed in triplicate at multiple dilution levels with the surrogate host Mycobacterium smegmatis, were used to quantify phage titer. Respective titer reductions for the vibrating mesh nebulizer, jet nebulizer, and soft mist inhaler were 0.4 ± 0.1, 3.7 ± 0.1, and 0.6 ± 0.3 log 10 (pfu/mL). Active phage delivery rate was significantly greater (p pfu/min) than for the jet nebulizer (5.4x10 4  ± 1.3x10 4 pfu/min). The soft mist inhaler delivered 4.6x10 6  ± 2.0x10 6 pfu per 11.6 ± 1.6 μL ex-actuator dose. Delivering active phage requires a prudent choice of inhalation device. The jet nebulizer was not a good choice for aerosolizing phage D29 under the tested conditions, due to substantial titer reduction likely occurring during droplet production. The vibrating mesh nebulizer is recommended for animal inhalation studies requiring large amounts of D29 aerosol, whereas the soft mist inhaler may be useful for self-administration of D29 aerosol.

  3. Microbiological evaluation of ultrasonic nebulization for disinfecting dental impressions.

    Science.gov (United States)

    Mendonca, Marcio Jose; Rafael, Renata Santos; Camilotti, Veridiana; Menolli, Rafael Andrade; Sicoli, Eliseu Augusto; Teixeira, Nancielli; Sinhoreti, Mario Alexandre Coelho

    2013-07-01

    Disinfecting dental impressions is necessary to decrease the risk of cross-contamination in dental offices. Ultrasonic nebulization has been mentioned as a microbicidal technique that can be used to disinfect contaminated dental impressions. This study compared the microbicidal effect of 2% glutaraldehyde and 0.2% peracetic acid for the disinfection of dental impressions made with vinyl polysiloxane, using 2 disinfection methods: immersion and ultrasonic nebulization. Bactericial efficacy was examined using Staphylococcus aureus and Bacillus atrophaeus as indicators. Thirty impressions were obtained and distributed randomly in 5 groups (n = 6). Group 1 was immersed in 2% glutaraldehyde immersion for 10 minutes, Group 2 was immersed in 0.2% peracetic acid for 10 minutes, Group 3 underwent ultrasonic nebulization for 10 minutes in 2% glutaraldehyde solution, Group 4 underwent ultrasonic nebulization for 10 minutes in 0.2% peracetic acid solution, and Group 5 was a control group that received no disinfectant. Both solutions experienced a 100% reduction in microorganisms following ultrasonic nebulization, as did peracetic acid following immersion; however, immersion in glutaraldehyde demonstrated lower values of reduction in B atrophaeus group, with a statistically significant difference compared with the other experimental groups.

  4. The characteristics of a pneumatic muscle

    OpenAIRE

    Pietrala Dawid

    2017-01-01

    The article presents static and dynamic characteristics of pneumatic muscles. It presents the structure of the laboratory stand used to test pneumatic muscles. It discusses the methodology for determination of static and dynamic characteristics. The paper also illustrates characteristics showing the relationship of pneumatic muscles length and operating pressure, at a constant loading force (isotonic characteristics). It presents characteristics showing the relationship of pneumatic muscles s...

  5. Jet and ultrasonic nebulization of single chain urokinase plasminogen activator (scu-PA)

    DEFF Research Database (Denmark)

    Münster, Anna-Marie; Bendstrup, E; Jensen, J.I.

    2000-01-01

    locally by nebulization in a recombinant zymogen form as single chain urokinase plasminogen activator (scu-PA). We aimed to characterize the particle size distribution, drug output, and enzymatic activity of scu-PA after nebulization with a Ventstream jet nebulizer (Medic-Aid, Bognor Regis, UK) and a Syst...

  6. Nebulized naloxone gently and effectively reverses methadone intoxication.

    Science.gov (United States)

    Mycyk, Mark B; Szyszko, Amy L; Aks, Steven E

    2003-02-01

    A 46-year-old woman presented to the Emergency Department with lethargy and respiratory depression after ingesting methadone. Initial oxygen saturation of 61% on room air did not improve with supplemental oxygenation. As venous access was initially unobtainable, naloxone was administered by nebulizer. Within 5 min oxygen saturation was 100% and mental status was normal. The patient did not develop severe withdrawal symptoms. Naloxone hydrochloride has been administered by various routes to treat opioid toxicity. Our report describes the successful use of nebulized naloxone for methadone toxicity.

  7. Complications of occipital bone pneumatization

    International Nuclear Information System (INIS)

    Moss, Mary; Roche, Jim; Biggs, Michael; Forer, Martin; Fagan, Paul; Davis, Martin

    2004-01-01

    Four cases of occipital bone pneumatization and subsequent complications are described, which include a pathological fracture of C 1 and the occipital bone, spontaneous subcutaneous emphysema and pneumatocele formation. Reviews of the published literature and possible aetiological factors have been discussed Copyright (2004) Blackwell Publishing Asia Pty Ltd

  8. The characteristics of a pneumatic muscle

    Directory of Open Access Journals (Sweden)

    Pietrala Dawid

    2017-01-01

    Full Text Available The article presents static and dynamic characteristics of pneumatic muscles. It presents the structure of the laboratory stand used to test pneumatic muscles. It discusses the methodology for determination of static and dynamic characteristics. The paper also illustrates characteristics showing the relationship of pneumatic muscles length and operating pressure, at a constant loading force (isotonic characteristics. It presents characteristics showing the relationship of pneumatic muscles shortening and values of loading forces, at a constant operational pressure (isobaric characteristics. It also shows the dependence of force generated by the muscle on the operating pressure, at a constant value of pneumatic muscles shortening (isometric characteristics. The paper also presents dynamic characteristics of a pneumatic muscle showing the response of an object to a gradual change in the operating pressure, at a constant loading force acting on the pneumatic muscle.

  9. The characteristics of a pneumatic muscle

    Science.gov (United States)

    Pietrala, Dawid

    The article presents static and dynamic characteristics of pneumatic muscles. It presents the structure of the laboratory stand used to test pneumatic muscles. It discusses the methodology for determination of static and dynamic characteristics. The paper also illustrates characteristics showing the relationship of pneumatic muscles length and operating pressure, at a constant loading force (isotonic characteristics). It presents characteristics showing the relationship of pneumatic muscles shortening and values of loading forces, at a constant operational pressure (isobaric characteristics). It also shows the dependence of force generated by the muscle on the operating pressure, at a constant value of pneumatic muscles shortening (isometric characteristics). The paper also presents dynamic characteristics of a pneumatic muscle showing the response of an object to a gradual change in the operating pressure, at a constant loading force acting on the pneumatic muscle.

  10. Orthopaedic Rehabilitation Device Actuated with Pneumatic Muscles

    Directory of Open Access Journals (Sweden)

    Ioana Petre

    2014-07-01

    Full Text Available Year after year recovery clinics worldwide report significant numbers of lower limb bearing joint disabilities. An effective method for the speedy rehabilitation of patients with such afflictions is Continuous Passive Motion (CPM, drawing upon a range of specific equipment. This paper presents an innovative constructive solution for such orthopaedic rehabilitation equipment, designed to ensure a swift reintegration of patients at as low a cost as possible. The absolute novelty consists in the utilization of the linear pneumatic muscle as actuator of the orthopaedic rehabilitation equipment, thus achieving a light and highly compliant construction that satisfies safety requirements related to man-machine interaction. Pneumatic muscles are bio-inspired actuation systems characterized by a passive variable compliant behaviour. This property, deployed in rehabilitation systems, enables the development of human friendly devices, which are comfortable for the patients, and capable of safe interaction. This paper presents the constructive schematic of the orthopaedic rehabilitation equipment, the structure of the actuation and positioning system, and several of its functional characteristics.

  11. Efficacy of nebulized furosemide in children with moderate attack of ...

    African Journals Online (AJOL)

    Efficacy of nebulized furosemide in children with moderate attack of asthma. M Alshehri, T Almegamesi, A Alfrayh. Abstract. No Abstract. West African Journal of Medicine Vol. 24(3) 2005: 246-251. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT.

  12. Optimization of nebulized delivery of linezolid, daptomycin, and vancomycin aerosol

    Directory of Open Access Journals (Sweden)

    Zarogoulidis P

    2014-08-01

    Full Text Available Paul Zarogoulidis,1 Ioannis Kioumis,1 Sofia Lampaki,1 John Organtzis,1 Konstantinos Porpodis,1 Dionysios Spyratos,1 Georgia Pitsiou,1 Dimitris Petridis,2 Athanasia Pataka,1 Haidong Huang,3 Qiang Li,3 Lonny Yarmus,4 Wolfgang Hohenforst-Schmidt,5 Nikolaos Pezirkianidis,6 Konstantinos Zarogoulidis1 1Pulmonary Department-Oncology Unit, “G Papanikolaou” General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece; 2Department of Food Technology, School of Food Technology and Nutrition, Alexander Technological Educational Institute, Thessaloniki, Greece; 3Department of Respiratory Diseases, Shanghai Hospital, II Military University Hospital, Shanghai, People’s Republic of China; 4Division of Pulmonary and Critical Care Medicine, Johns Hopkins University, Baltimore, MD, USA; 5II Medical Department, “Coburg” Regional Hospital, Coburg, Germany; 6Surgery Department, Private Cabinet, Serres, Greece Background: At this time, several antibiotics have been investigated as possibilities for aerosol administration, but local therapy has been found to be more efficient in several diseases. Materials and methods: The drugs linezolid (Zyvox, vancomycin (Voncon, and daptomycin (Cubicin were tested with three jet nebulizers with seven different residual cups and different loadings. Moreover, three ultrasound nebulizers were again tested with these drugs, with different loadings and mouthpiece attachments. Results: When drugs are combined with particular cup designs, they significantly lower the droplet size to 1.60 and 1.80 µm, which represents the best combination of Zyvox and cup G and Cubicin and cup D, respectively. Cup design D is suggested as the most effective cup for lowering the droplet size (2.30 µm when considering a higher loading level (8 mL. Conclusion: Modification of current drugs from dry powder to solution is possible, and the residual cup design plays the most important role in droplet size production when the

  13. Sliding pressure control valve for pneumatic hammer drill

    Science.gov (United States)

    Polsky, Yarom [Albuquerque, NM

    2011-08-30

    A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.

  14. Efficacy of nebulized fluticasone propionate in adult patients admitted to the emergency department due to bronchial asthma attack.

    Science.gov (United States)

    Starobin, Daniel; Bolotinsky, Ludmila; Or, Jack; Fink, Gershon; Shtoeger, Zev

    2008-01-01

    Locally delivered steroids by inhalers or nebulizers have been shown in small trials to be effective in acute asthma attack, but evidence-based data are insufficient to establish their place as routine management of adult asthma attacks. To determine the efficacy of nebulized compared to systemic steroids in adult asthmatics admitted to the emergency department following an acute attack. Adult asthmatics admitted to the ED were assigned in random consecutive case fashion to one of three protocol groups: group 1--nebulized steroid fluticasone (Flixotide Nebules), group 2--intravenous methylprednisolone, group 3--combined treatment by both routes. Objective and subjective parameters, such as peak expiratory flow, oxygen saturation, heart rate and dyspnea score, were registered before and 2 hours after ED treatment was initiated. Steroids were continued for 1 week following the ED visit according to the protocol arm. Data on hospital admission/discharge rate, ED readmissions in the week after enrollment and other major events related to asthma were registered. Altogether, 73 adult asthmatics were assigned to receive treatment: 24 patients in group 1, 23 in group 2 and 26 in group 3. Mean age was 44.4 +/- 16.8 years (range 17-75 years). Peak expiratory flow and dyspnea score significantly improved in group 1 patients compared with patients in the other groups after 2 hours of ED treatment (P = 0.021 and 0.009, respectively). The discharge rate after ED treatment was significantly higher in groups 1 and 3 than in group 2 (P = 0.05). All 73 patients were alive a week after enrollment. Five patients (20.8%) in the Flixotide treatment arm were hospitalized and required additional systemic steroids. Multivariate analysis of factors affecting hospitalization rate demonstrated that severity of asthma (odds ratio 8.11) and group 2 (OD 4.17) had a negative effect, whereas adherence to chronic anti-asthma therapy (OD 0.49) reduced the hospitalization rate. Our study cohort

  15. Pneumatic tourniquets in extremity surgery.

    LENUS (Irish Health Repository)

    Wakai, A

    2012-02-03

    Pneumatic tourniquets maintain a relatively bloodless field during extremity surgery, minimize blood loss, aid identification of vital structures, and expedite the procedure. However, they may induce an ischemia-reperfusion injury with potentially harmful local and systemic consequences. Modern pneumatic tourniquets are designed with mechanisms to regulate and maintain pressure. Routine maintenance helps ensure that these systems are working properly. The complications of tourniquet use include postoperative swelling, delay of recovery of muscle power, compression neurapraxia, wound hematoma with the potential for infection, vascular injury, tissue necrosis, and compartment syndrome. Systemic complications can also occur. The incidence of complications can be minimized by use of wider tourniquets, careful preoperative patient evaluation, and adherence to accepted principles of tourniquet use.

  16. Model for pneumatic pellet injection

    International Nuclear Information System (INIS)

    Hogan, J.T.; Milora, S.L.; Schuresko, D.D.

    1983-07-01

    A hydrodynamic code has been developed to model the performance of pneumatic pellet injection systems. The code describes one dimensional, unsteady compressible gas dynamics, including gas friction and heat transfer to the walls in a system with variable area. The mass, momentum, and energy equations are solved with an iterated Lax-Wendroff scheme with additional numerical viscosity. The code is described and comparisons with experimental data are presented

  17. Bipolar Mass Spectrometry of Labile Coordination Complexes, Redox Active Inorganic Compounds, and Proteins Using a Glass Nebulizer for Sonic-Spray Ionization

    Science.gov (United States)

    Antonakis, Manolis M.; Tsirigotaki, Alexandra; Kanaki, Katerina; Milios, Constantinos J.; Pergantis, Spiros A.

    2013-08-01

    In this study, we report on the development of a novel nebulizer configuration for sonic-spray ionization (SSI) mass spectrometry (MS), more specifically for a version of SSI that is referred to as Venturi easy ambient sonic-spray ionization (V-EASI) MS. The developed nebulizer configuration is based on a commercially available pneumatic glass nebulizer that has been used extensively for aerosol formation in atomic spectrometry. In the present study, the nebulizer was modified in order to achieve efficient V-EASI-MS operation. Upon evaluating this system, it has been demonstrated that V-EASI-MS offers some distinct advantages for the analysis of coordination compounds and redox active inorganic compounds over the predominantly used electrospray ionization (ESI) technique. Such advantages, for this type of compounds, are demonstrated here for the first time. More specifically, a series of labile heptanuclear heterometallic [CuII 6LnIII] clusters held together with artificial amino acid ligands, in addition to easily oxidized inorganic oxyanions of selenium and arsenic, were analyzed. The observed advantages pertain to V-EASI appearing to be a "milder" ionization source than ESI, not requiring electrical potentials for gas phase ion formation, thus eliminating the possibility of unwanted redox transformations, allowing for the "simultaneous" detection of negative and positive ions (bipolar analysis) without the need to change source ionization conditions, and also not requiring the use of syringes and delivery pumps. Because of such features, especially because of the absence of ionization potentials, EASI can be operated with minimal requirements for source parameter optimization. We observed that source temperature and accelerating voltage do not seem to affect labile compounds to the extent they do in ESI-MS. In addition, bipolar analysis of proteins was demonstrated here by acquiring both positive and negative ion mass spectra from the same protein solutions

  18. Linear pneumatic motors – a comparative study

    Directory of Open Access Journals (Sweden)

    Deaconescu Tudor

    2017-01-01

    Full Text Available The paper presents a comparative study of the performance of single-acting cylinders, diaphragm cylinders and pneumatic muscles, and offers users information that allows the selection of an optimum technical solution. Such a study was necessary, in view of the numerous papers on pneumatic muscle applications found in literature, that assert the superiority of pneumatic muscles over other pneumatic linear motors in relation to quantities like dimensions, mass, developed force or energy-to-mass ratios, however without offering concrete data.

  19. Protein stability in pulmonary drug delivery via nebulization.

    Science.gov (United States)

    Hertel, Sebastian P; Winter, Gerhard; Friess, Wolfgang

    2015-10-01

    Protein inhalation is a delivery route which offers high potential for direct local lung application of proteins. Liquid formulations are usually available in early stages of biopharmaceutical development and nebulizers are the device of choice for atomization avoiding additional process steps like drying and enabling fast progression to clinical trials. While some proteins were proven to remain stable throughout aerosolization e.g. DNase, many biopharmaceuticals are more susceptible towards the stresses encountered during nebulization. The main reason for protein instability is unfolding and aggregation at the air-liquid interface, a problem which is of particular challenge in the case of ultrasound and jet nebulizers due to recirculation of much of the generated droplets. Surfactants are an important formulation component to protect the sensitive biomolecules. A second important challenge is warming of ultrasound and vibrating mesh devices, which can be overcome by overfilling, precooled solutions or cooling of the reservoir. Ultimately, formulation development has to go hand in hand with device evaluation. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Determination of low cadmium concentrations in wine by on-line preconcentration in a knotted reactor coupled to an inductively coupled plasma optical emission spectrometer with ultrasonic nebulization

    Energy Technology Data Exchange (ETDEWEB)

    Lara, R.F. [Inst. de Investigaciones Mineras, Universidad Nacional de San Juan (Argentina); Wuilloud, R.G.; Salonia, J.A. [Dept. of Analytical Chemistry, National University of San Luis (Argentina); Olsina, R.A.; Martinez, L.D. [Dept. of Analytical Chemistry, National University of San Luis (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) (Argentina)

    2001-12-01

    An on-line cadmium preconcentration and determination system implemented with inductively coupled plasma optical emission spectrometry (ICP-OES) associated to flow injection (FI) with ultrasonic nebulization system (USN) was studied. The cadmium was retained as the cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol, Cd-(5-Br-PADAP), complex, at pH 9.5. The cadmium complex was removed from the knotted reactor (KR) with 3.0 mol/L nitric acid. A total enhancement factor of 216 was obtained with respect to ICP-OES using pneumatic nebulization (12 for USN and 18 for KR) with a preconcentration time of 60 s. The value of the detection limit for the preconcentration of 5 mL of sample solution was 5 ng/L. The precision for 10 replicate determinations at the 5 {mu}g/L Cd level was 2.9% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for cadmium was linear with a correlation coefficient of 0.9998 at levels near the detection limits up to at least 1000 {mu}g/L. The method was successfully applied to the determination of cadmium in wine samples. (orig.)

  1. Buckling Pneumatic Linear Actuators Inspired by Muscle

    OpenAIRE

    Yang, Dian; Verma, Mohit Singh; So, Ju-Hee; Mosadegh, Bobak; Keplinger, Christoph; Lee, Benjamin; Khashai, Fatemeh; Lossner, Elton Garret; Suo, Zhigang; Whitesides, George McClelland

    2016-01-01

    The mechanical features of biological muscles are difficult to reproduce completely in synthetic systems. A new class of soft pneumatic structures (vacuum-actuated muscle-inspired pneumatic structures) is described that combines actuation by negative pressure (vacuum), with cooperative buckling of beams fabricated in a slab of elastomer, to achieve motion and demonstrate many features that are similar to that of mammalian muscle.

  2. Pneumatic pellet injector for JET

    International Nuclear Information System (INIS)

    Andelfinger, C.; Buechl, K.; Jacobi, D.; Sandmann, W.; Schiedeck, J.; Schilling, H.B.; Weber, G.

    1983-07-01

    Pellet injection is a useful tool for plasma diagnostics of tokamaks. Pellets can be applied for investigation of particle, energy and impurity transport, fueling efficiency and magnetic surfaces. Design, operation and control of a single shot pneumatic pellet gun is described in detail including all supplies, the vacuum system and the diagnostics of the pellet. The arrangement of this injector in the torus hall and the interfaces to the JET system and CODAS are considered. A guide tube system for pellet injection is discussed but it will not be recommended for JET. (orig.)

  3. The role of osmolality in saline fluid nebulization after tracheostomy: time for changing?

    Science.gov (United States)

    Wen, Zunjia; Wu, Chao; Cui, Feifei; Zhang, Haiying; Mei, Binbin; Shen, Meifen

    2016-12-09

    Saline fluid nebulization is highly recommend to combat the complications following tracheostomy, yet the understandings on the role of osmolality in saline solution for nebulization remain unclear. To investigate the biological changes in the early stage after tracheostomy, to verify the efficacy of saline fluid nebulization and explore the potential role of osmolality of saline nebulization after tracheostomy. Sprague-Dawley rats undergone tracheostomy were taken for study model, the sputum viscosity was detected by rotational viscometer, the expressions of TNF-α, AQP4 in bronchoalveolar lavage fluid were assessed by western blot analysis, and the histological changes in endothelium were evaluated by HE staining and scanning electron microscopy (SEM). Study results revealed that tracheostomy gave rise to the increase of sputum viscosity, TNF-α and AQP4 expression, mucosa and cilia damage, yet the saline fluid nebulization could significantly decrease the changes of those indicators, besides, the hypertonic, isotonic and hypertonic saline nebulization produced different efficacy. Osmolality plays an important role in the saline fluid nebulization after tracheostomy, and 3% saline fluid nebulization seems to be more beneficial, further studies on the role of osmolality in saline fluid nebulization are warranted.

  4. A Study of Gas Economizing Pneumatic Cylinder

    International Nuclear Information System (INIS)

    Li, T C; Wu, H W; Kuo, M J

    2006-01-01

    The pneumatic cylinder is the most typical actuator in the pneumatic equipment, and its mechanism is so simple that it is often used to operate point to point driving without the feedback loop in various automatic machines. But, the energy efficiency of pneumatic system is very poor compared with electrical systems and hydraulic systems. So, it is very important to discuss the energy saving for the pneumatic cylinder systems. In this thesis, we proposed three methods to apply the reduction in the air consumed for pneumatic cylinder systems. An air charge accumulator is used to absorb the exhausted compress air and a boost valve boosted the air to the higher pressure for used again. From the experiments, the direct used cylinder exhaust air may save about 40% of compress air

  5. Pneumatic automation systems in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Shmatkov, N.A.; Kiklevich, Yu.N.

    1981-04-01

    Giprougleavtomatizatsiya, Avtomatgormash, Dongiprouglemash, VNIIGD and other plants develop 30 new pneumatic systems for mine machines and equipment control each year. The plants produce about 200 types of pneumatic systems. Major pneumatic systems for face systems, machines and equipment are reviewed: Sirena system for remote control of ANShch and AShchM face systems for steep coal seams, UPS control systems for pump stations, PAUZA control system for stowing machines, remote control system of B100-200 drilling machines, PUSK control system for coal cutter loaders with pneumatic drive (A-70, Temp), PUVSh control system for ventilation barriers activated from moving electric locomotives, PAZ control system for skip hoist loading. Specifications of the systems are given. Economic benefit produced by the pneumatic control systems are evaluated (from 1,500 to 40,000 rubles/year). Using the systems increases productivity of face machines and other machines used in black coal mines by 5 to 30%.

  6. Surface acoustic wave nebulization of peptides as a microfluidic interface for mass spectrometry.

    Science.gov (United States)

    Heron, Scott R; Wilson, Rab; Shaffer, Scott A; Goodlett, David R; Cooper, Jonathan M

    2010-05-15

    We describe the fabrication of a surface acoustic wave (SAW) device on a LiNbO(3) piezoelectric transducer for the transfer of nonvolatile analytes to the gas phase at atmospheric pressure (a process referred to as nebulization or atomization). We subsequently show how such a device can be used in the field of mass spectrometry (MS) detection, demonstrating that SAW nebulization (SAWN) can be performed either in a discontinuous or pulsed mode, similar to that for matrix assisted laser desorption ionization (MALDI) or in a continuous mode like electrospray ionization (ESI). We present data showing the transfer of peptides to the gas phase, where ions are detected by MS. These peptide ions were subsequently fragmented by collision-induced dissociation, from which the sequence was assigned. Unlike MALDI mass spectra, which are typically contaminated with matrix ions at low m/z, the SAWN generated spectra had no such interference. In continuous mode, the SAWN plume was sampled on a microsecond time scale by a linear ion trap mass spectrometer and produced multiply charged peptide precursor ions with a charge state distribution shifted to higher m/z compared to an identical sample analyzed by ESI. The SAWN technology also provides the opportunity to re-examine a sample from a flat surface, repeatedly. The process can be performed without the need for capillaries, which can clog, reservoirs, which dilute the sample, and electrodes, which when in direct contact with sample, cause unwanted electrochemical oxidation. In both continuous and pulsed sampling modes, the quality of precursor ion scans and tandem mass spectra of peptides was consistent across the plume's lifetime.

  7. Elbow joint rehabilitation equipment actuated by pneumatic muscles

    Directory of Open Access Journals (Sweden)

    Vetrice Georgiana

    2017-01-01

    Full Text Available The mobility of the limbs is an essential prerequisite for the individual’s physical autonomy. For persons suffering from post-traumatic affections of the elbow joint such limited mobility results in barriers in fulfilling personal or professional tasks. Passive motion has certain specific advantages and beneficial effects, thus being highly recommended for the recovery of injured joints. The paper presents a model of rehabilitation equipment that induces continuous passive motion of the elbow, as part of a recovery programme. The equipment is actuated by pneumatic muscles, using compressed air as the source of energy that generates force and motion. The main benefits of the pneumatic actuation system compared to other driving systems are its low cost, simple and robust construction and swift response to commands. Its constructive simplicity and reduced cost adds to the system’s eligibility for deployment in medical units.

  8. Synthesis of pneumatic controll systems

    Directory of Open Access Journals (Sweden)

    D. Nowak

    2011-04-01

    Full Text Available Currently, the basic tool for automating the production processes are the PLCs. However, in many areas application of the pneumaticcontrol systems may be more reasonable. The main factor determining choice of the control technology are costs. In the case of pneumaticsystems, the costs shall be determined by the number of elements used. Therefore, during the design works it is important to choose anappropriate method for the pneumatic control systems synthesis. The article presents the MTS method, which may be used for a discretetechnological processes modeling and PLC programming, as well as for a pneumatic control systems designing. An important element ofthe MTS method is the network of actions, which graphically presents an algorithm of the implemented process. Based on the actionnetwork and operating machine’s functional diagram, the diagram of different states is determinated, which graphically shows changes ofthe control system’s input and output signals. Analysis of the diagram of different states, makes it easy to determine a schematic equation, which shall be the basis for the control system implementation. Advantage of the MTS method is the lack of restrictions on the number of the control system’s input and output signals. The resulting solution is characterized by a minimum number of elements needed to implement the control system.

  9. Pneumatic Variable Series Elastic Actuator.

    Science.gov (United States)

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-08-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on-off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator.

  10. Caudal pneumaticity and pneumatic hiatuses in the sauropod dinosaurs Giraffatitan and Apatosaurus.

    Directory of Open Access Journals (Sweden)

    Mathew J Wedel

    Full Text Available Skeletal pneumaticity is found in the presacral vertebrae of most sauropod dinosaurs, but pneumaticity is much less common in the vertebrae of the tail. We describe previously unrecognized pneumatic fossae in the mid-caudal vertebrae of specimens of Giraffatitan and Apatosaurus. In both taxa, the most distal pneumatic vertebrae are separated from other pneumatic vertebrae by sequences of three to seven apneumatic vertebrae. Caudal pneumaticity is not prominent in most individuals of either of these taxa, and its unpredictable development means that it may be more widespread than previously recognised within Sauropoda and elsewhere in Saurischia. The erratic patterns of caudal pneumatization in Giraffatitan and Apatosaurus, including the pneumatic hiatuses, show that pneumatic diverticula were more broadly distributed in the bodies of the living animals than are their traces in the skeleton. Together with recently published evidence of cryptic diverticula--those that leave few or no skeletal traces--in basal sauropodomorphs and in pterosaurs, this is further evidence that pneumatic diverticula were widespread in ornithodirans, both across phylogeny and throughout anatomy.

  11. History of aerosol therapy: liquid nebulization to MDIs to DPIs.

    Science.gov (United States)

    Anderson, Paula J

    2005-09-01

    Inhaled therapies have been used since ancient times and may have had their origins with the smoking of datura preparations in India 4,000 years ago. In the late 18th and in the 19th century, earthenware inhalers were popular for the inhalation of air drawn through infusions of plants and other ingredients. Atomizers and nebulizers were developed in the mid-1800s in France and were thought to be an outgrowth of the perfume industry as well as a response to the fashion of inhaling thermal waters at spas. Around the turn of the 20th century, combustible powders and cigarettes containing stramonium were popular for asthma and other lung complaints. Following the discovery of the utility of epinephrine for treating asthma, hand-bulb nebulizers were developed, as well as early compressor nebulizers. The marketing of the first pressurized metered-dose inhaler for epinephrine and isoproterenol, by Riker Laboratories in 1956, was a milestone in the development of inhaled drugs. There have been remarkable advances in the technology of devices and formulations for inhaled drugs in the past 50 years. These have been influenced greatly by scientific developments in several areas: theoretical modeling and indirect measures of lung deposition, particle sizing techniques and in vitro deposition studies, scintigraphic deposition studies, pharmacokinetics and pharmacodynamics, and the 1987 Montreal Protocol, which banned chlorofluorocarbon propellants. We are now in an era of rapid technologic progress in inhaled drug delivery and applications of aerosol science, with the use of the aerosolized route for drugs for systemic therapy and for gene replacement therapy, use of aerosolized antimicrobials and immunosuppressants, and interest in specific targeting of inhaled drugs.

  12. Synthesis of Servo Pneumatic/Hydraulic Drive

    Directory of Open Access Journals (Sweden)

    K D. Efremova

    2017-01-01

    Full Text Available Servo pneumatic and / or hydraulic drives are widely used in modern engineering and process control. The efficiency of using pneumatic / hydraulic drives depends on their parameters and characteristics. To select the optimal drive parameters, various methods are used, based on finding the minimum of the target (target or criteria function.The objective of this paper was to apply one crucial criterion (target function that provides determination of optimal parameters of the pneumatic / hydraulic drive with the translational motion of the end-effector as well as its use in the synthesis of the servo pneumatic cylinder. The article shows the form of the target function representing a set of drive parameters that do not have direct relationships with each other in a dimensionless form for the pneumatic / hydraulic drive with the translational motion of the end-effector. To calculate the parameters of the servo drive close to the optimal ones, a two-criteria LPτ search was used. As criteria, were used the decisive criterion - the proposed target function, and the power developed by the actuator of the pneumatic / hydraulic drive, which were presented in a dimensionless form. It is shown that the criterion for solution optimality is the minimum distance of the selected point in the space of the normalized criteria from the origin. This point was determined. In addition to the proposed criteria, non-formalised requirements were taken into account: actual and mass-produced components of drive, in terms of which its parameters close to the optimal ones were determined, and the maximum relative error of the obtained useful power value of the servo pneumatic drive was estimated. The paper presents design features of two types of the servo pneumatic drive created, taking into account the proposed target function, implemented according to the schemes "hidden" and "spaced apart". The experimental static characteristic of the servo pneumatic drive is

  13. Nebulized hyaluronan ameliorates lung inflammation in cystic fibrosis mice.

    Science.gov (United States)

    Gavina, Manuela; Luciani, Alessandro; Villella, Valeria R; Esposito, Speranza; Ferrari, Eleonora; Bressani, Ilaria; Casale, Alida; Bruscia, Emanuela M; Maiuri, Luigi; Raia, Valeria

    2013-08-01

    Chronic lung inflammation with increased susceptibility to bacterial infections cause much of the morbidity and mortality in patients with cystic fibrosis (CF), the most common severe, autosomal recessively inherited disease in the Caucasian population. Exogenous inhaled hyaluronan (HA) can exert a protective effect against injury and beneficial effects of HA have been shown in experimental models of chronic respiratory diseases. Our objective was to examine whether exogenous administration of nebulized HA might interfere with lung inflammation in CF. F508del homozygous mice (Cftr(F508del) ) and transgenic mice overexpressing the ENaC channel β-subunit (Scnn1b-Tg) were treated with nebulized HA (0.5 mg/mouse/day for 7 days). Tumor necrosis factor-alpha (TNFα), macrophage inflammatory protein-2 (MIP-2), myeloperoxidase (MPO) levels, and macrophage infiltration were assessed on lung tissues. IB3-1 and CFBE41o-epithelial cell lines were cultured with HA (24 hr, 100 µg/ml) and Reactive Oxygen Species (ROS), Tissue Transglutaminase (TG2) SUMOylation and Peroxisome Proliferator Activated Receptor gamma (PPARγ) and phospho-p42/p44 levels were measured by dichlorodihydrofluorescein assay, or fluorescence resonance energy transfer (FRET) microscopy or immunoblots. Nebulized HA reduced TNFα expression (P < 0.005); TNFα, MIP-2, and MPO protein levels (P < 0.05); MPO activity (P < 0.05); and CD68+ cells counts (P < 0.005) in lung tissues of Cftr(F508del) and Scnn1b-Tg mice, compared with saline-treated mice. HA reduced ROS, TG2 SUMOylation, TG2 activity, phospho-p42-44, and increased PPARγ protein in both IB3-1 and CFBE41o cells (P < 0.05). Nebulized HA is effective in controlling inflammation in vivo in mice CF airways and in vitro in human airway epithelial cells. We provide the proof of concept for the use of inhaled HA as a potential anti-inflammatory drug in CF therapy. Copyright © 2012 Wiley Periodicals, Inc.

  14. Magnetic core-shell nanoparticles for drug delivery by nebulization

    LENUS (Irish Health Repository)

    Verma, Navin Kumar

    2013-01-23

    AbstractBackgroundAerosolized therapeutics hold great potential for effective treatment of various diseases including lung cancer. In this context, there is an urgent need to develop novel nanocarriers suitable for drug delivery by nebulization. To address this need, we synthesized and characterized a biocompatible drug delivery vehicle following surface coating of Fe3O4 magnetic nanoparticles (MNPs) with a polymer poly(lactic-co-glycolic acid) (PLGA). The polymeric shell of these engineered nanoparticles was loaded with a potential anti-cancer drug quercetin and their suitability for targeting lung cancer cells via nebulization was evaluated.ResultsAverage particle size of the developed MNPs and PLGA-MNPs as measured by electron microscopy was 9.6 and 53.2 nm, whereas their hydrodynamic swelling as determined using dynamic light scattering was 54.3 nm and 293.4 nm respectively. Utilizing a series of standardized biological tests incorporating a cell-based automated image acquisition and analysis procedure in combination with real-time impedance sensing, we confirmed that the developed MNP-based nanocarrier system was biocompatible, as no cytotoxicity was observed when up to 100 mug\\/ml PLGA-MNP was applied to the cultured human lung epithelial cells. Moreover, the PLGA-MNP preparation was well-tolerated in vivo in mice when applied intranasally as measured by glutathione and IL-6 secretion assays after 1, 4, or 7 days post-treatment. To imitate aerosol formation for drug delivery to the lungs, we applied quercitin loaded PLGA-MNPs to the human lung carcinoma cell line A549 following a single round of nebulization. The drug-loaded PLGA-MNPs significantly reduced the number of viable A549 cells, which was comparable when applied either by nebulization or by direct pipetting.ConclusionWe have developed a magnetic core-shell nanoparticle-based nanocarrier system and evaluated the feasibility of its drug delivery capability via aerosol administration. This study has

  15. New Form of Hypertonic Solution for Nebulization Therapy

    Directory of Open Access Journals (Sweden)

    Olga I. Simonova

    2016-01-01

    Full Text Available Mucolytic, expectorative and antitussive drugs are traditionally used in acute or chronic respiratory episodes affected by acute respiratory infections. Today, preference is given to drugs in a form of solutions for nebulization therapy. The article presents data on the new dosage form of 7% inhalation hypertonic solution in combination with hyaluronic acid used in mucostasis therapy for chronic respiratory diseases. The information on the properties and the favorable effect of hyaluronic acid is provided. We discuss the evidence base of inhalation of the hypertonic solution in combination with hyaluronic acid in cystic fibrosis.

  16. Surfactant nebulization versus instillation during high frequency ventilation in surfactant-deficient rabbits

    NARCIS (Netherlands)

    Dijk, Peter H.; Heikamp, A; Bambang Oetomo, Sidarto

    Surfactant nebulization improves lung function at low alveolar doses of surfactant. However, efficiency of nebulization is low, and lung deposition seems to depend on lung aeration. High frequency ventilation (HFV) has been shown to improve lung aeration. We hypothesize that the combination of HFV

  17. Disposition of nebulized pentamidine measured using the direct radiolabel 123I-iodopentamidine

    International Nuclear Information System (INIS)

    O'Doherty, M.J.; Nunan, T.O.; Bateman, N.T.; Thomas, S.H.L.; Page, C.J.; Blower, P.J.

    1993-01-01

    The pulmonary deposition of nebulized pentamidine (300 mg, Respirgard II nebulizer) was measured in seven human immunodeficiency virus (HIV)-positive men using a new radiopharmaceutical, 123 I-iodopentamidine. Mean total pulmonary deposition was 15.3 mg or 5.1% of the initial nebulizer dose. Further studies in two of the patients showed that at 24h, 87% of deposited 123 I was retained in the lungs. Small amounts of activity (expressed as a percentage of the initial nebulizer activity) were also detected over the thyroid (0.4%), bladder (1%) and gut (0.7%). The ratio of 123 I activity to pentamidine concentration was similar in the nebulizer solution and urine. These results suggest that 123 I-pentamidine may be sufficiently stable in vivo to be used to study the biodistribution of inhaled and parenteral pentamidine in humans. (author)

  18. Baby bottle steam sterilizers for disinfecting home nebulizers inoculated with non-tuberculous mycobacteria.

    Science.gov (United States)

    Towle, D; Callan, D A; Lamprea, C; Murray, T S

    2016-03-01

    Non-tuberculous mycobacteria (NTMb), present in environmental water sources, can contribute to respiratory infection in patients with chronic pulmonary disease. Contaminated nebulizers are a potential source of respiratory infection. Treatment with baby bottle steam sterilizers disinfects home nebulizers inoculated with bacterial pathogens but whether this method works for disinfection of NTMb is unclear. Baby bottle steam sterilization was compared with vigorous water washing for disinfecting home nebulizers inoculated with NTMb mixed with cystic fibrosis sputum. No NTMb was recovered from any nebulizers after steam treatment whereas viable NTMb grew after water washing, demonstrating that steam sterilization effectively disinfects NTMb-inoculated nebulizers. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  19. Baby bottle steam sterilizers disinfect home nebulizers inoculated with bacterial respiratory pathogens.

    Science.gov (United States)

    Towle, Dana; Callan, Deborah A; Farrel, Patricia A; Egan, Marie E; Murray, Thomas S

    2013-09-01

    Contaminated nebulizers are a potential source of bacterial infection but no single method is universally accepted for disinfection. We hypothesized that baby-bottle steam sterilizers effectively disinfect home nebulizers. Home nebulizers were inoculated with the common CF respiratory pathogens methicillin resistant Staphylococcus aureus, Burkholderia cepacia, Haemophilus influenzae, mucoid and non mucoid Pseudomonas aeruginosa, and Stenotrophomonas maltophilia. The nebulizers were swabbed for bacterial growth, treated with either the AVENT (Philips), the NUK Quick & Ready (Gerber) or DRY-POD (Camera Baby) baby bottle steam sterilizer and reswabbed for bacterial growth. All steam sterilizers were effective at disinfecting all home nebulizers. Viable bacteria were not recovered from any inoculated site after steam treatment, under any conditions tested. Steam treatment is an effective disinfection method. Additional studies are needed to confirm whether these results are applicable to the clinical setting. Copyright © 2012 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  20. Effect of Dead Volume on the Efficiency and the Cost to Deliver Medications in Cystic Fibrosis with Four Disposable Nebulizers

    Directory of Open Access Journals (Sweden)

    Sharon L Ho

    1999-01-01

    Full Text Available OBJECTIVES: To evaluate the factors that affect nebulizer efficiency and to compare the relative cost effectiveness of nebulized medications used in the treatment of cystic fibrosis (CF, delivered by four types of disposable jet nebulizers that are widely used in hospitals.

  1. Noise distribution of an incubator with nebulizer at a neonatal intensive care unit in southern Taiwan.

    Science.gov (United States)

    Chen, H F; Chang, Y J

    2001-06-01

    The purpose of this study was to investigate the noise distribution and sources of peak noise inside an incubator with a nebulizer at a neonatal intensive care unit of a medical center in Southern Taiwan. Sound levels were monitored continuously with an electronic sound-meter for 24 hours daily over a one-week period. Three working hours (day, evening, and night hours) in the weekday and weekend (total 48 hours) were selected randomly from the one-week period of noise survey to observe peak noise at levels > or = 65 dBA. Results revealed that 24.8% of the total monitoring period had sound levels at or = 70 dBA. Furthermore, a total of 947 peak noises > or = 65 dBA were found within the 48 hours, of which 61.5% were in a range of 65-69 dBA, 24% of 70-74 dBA, 9.8% of 75-79 dBA, and 4.8% > or = 80 dBA. Human-related sources, equaling 79%, were the dominant peak noises. These noises included opening and closing doors, banging the incubator hood, conversation among staff, nursing activity inside the incubator, tearing and opening paper or bags, opening and closing trash can lids, and bumping metal carts or other apparatus. Nonhuman-related sources were 21% including alarms of monitors and running of the incubator motor. Results of this study showed that the noise distribution in the incubator with nebulizer was far above a protective limitation of 58 dBA, suggested by the American Academy of Pediatrics in 1974. However, most peak noises could be reduced by modification of staff behavior. Therefore, determinations of noise distribution and sources of peak noise in this study are useful for further noise reduction programs.

  2. A retrospective analysis of nebulized versus intravenous fentanyl for renal colic.

    Science.gov (United States)

    Imamoglu, Melih; Aygun, Ali; Bekar, Omer; Erdem, Erkan; Cicek, Mustafa; Tatli, Ozgur; Karaca, Yunus; Sahin, Aynur; Turkmen, Suha; Turedi, Suleyman

    2017-05-01

    To assess the effectiveness of nebulized fentanyl used for analgesia in renal colic. This research was planned as a randomized, blinded study in which prospectively collected data were analyzed retrospectively to compare nebulized and intravenous (iv) fentanyl therapies. Patients with renal colic with 'moderate' or worse pain on a four-point verbal pain score (VPS) or with pain of 20mm or above on a 100-mm visual analogue score (VAS) at time of presentation were randomized into iv fentanyl (n=62) or nebulized fentanyl (n=53) study groups. Decreases in VAS and VPS scores at 15 and 30min compared to baseline, rescue analgesia requirements and side-effects between the groups were compared. Both iv fentanyl and nebulized fentanyl provided effective analgesia in renal colic patients at the end of 30min. However, iv fentanyl provided more rapid and more effective analgesia than nebulized fentanyl. Patients receiving iv fentanyl had lower rescue analgesia requirements than those receiving nebulized fentanyl (37.1% vs 54.7%), although the difference was not statistically significant (p=0.058). In addition, side-effects were more common in the iv fentanyl group compared to the nebulized fentanyl group (22.1% vs 9.4%), although the difference was also not significant (p=0.058). Nebulized fentanyl provides effective analgesia in patients with renal colic. However, iv fentanyl exhibits more rapid and more powerful analgesic effects than nebulized fentanyl. Nonetheless, due to its ease of use and few potential risks and side-effects the nebulized form can be used as an alternative in renal colic. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. A survey on pneumatic muscle actuators modeling

    OpenAIRE

    Kelasidi, Eleni; Andrikopoulos, Georgios; Nikolakopoulos, George; Manesis, Stamatis

    2012-01-01

    The aim of this article is to provide a survey on the most popular modeling approaches for Pneumatic Muscle Actuators (PMAs). PMAs are highly non-linear pneumatic actuators where their elongation is proportional to the interval pressure. During the last decade, there has been an increase in the industrial and scientific utilization of PMAs, due to their advantages such as high strength and small weight, while various types of PMAs with different technical characteristics have been appeared in...

  4. Dust emissions eliminated in pneumatic harvesting

    International Nuclear Information System (INIS)

    Kallio, M.

    1998-01-01

    Pneumatic harvesting is the most efficient milled peat production method in unsteady weather conditions. In good summers, the best contractors harvest more than 1 000 m 3 /ha milled peat from suitable production fields. The greatest problem of the method is caused by dust emissions, in particular in fields close to settled areas. About 15 % of Finland's present peat production is collected using pneumatic harvesters. A pneumatic harvester with smaller dust emissions has been developed by VTT Energy and Vapo Oy. The wagon is based on two-stage separation of peat. The main part of the coarser milled peat is first separated, e.g. in a settling chamber, and fine dry peat dust in correctly dimensioned side by side cyclones. The first series of pneumatic harvesters based on the new separation technology was employed in summer 1996. Besides decreasing the dust emissions the harvesting capacity of the new equipment was increased. The collection capacity of the pneumatic harvester can be made more effective by enlarging the container size, be decreasing the weight, by increasing the driving speed and by developing the suction capacity. Using lighter and durable construction materials combined with advanced design lighter and stronger pneumatic harvesters have been constructed. Nozzles and their mounting have also been developed. In the improvement of nozzles, the former studies with pneumatic simulator of VTT Energy, have been of great help. Studies with the pneumatic simulator and field conditions have been made in collaboration with Turveruukki Oy, Turvemetalli Oy, Raussin Metalli Oy and Vapo Oy, as well as VNIITP of St. Petersburg, Russia

  5. Fractional Order Models of Industrial Pneumatic Controllers

    Directory of Open Access Journals (Sweden)

    Abolhassan Razminia

    2014-01-01

    Full Text Available This paper addresses a new approach for modeling of versatile controllers in industrial automation and process control systems such as pneumatic controllers. Some fractional order dynamical models are developed for pressure and pneumatic systems with bellows-nozzle-flapper configuration. In the light of fractional calculus, a fractional order derivative-derivative (FrDD controller and integral-derivative (FrID are remodeled. Numerical simulations illustrate the application of the obtained theoretical results in simple examples.

  6. High-pressure portable pneumatic drive unit.

    Science.gov (United States)

    Hete, B F; Savage, M; Batur, C; Smith, W A; Golding, L A; Nosé, Y

    1989-12-01

    The left ventricular assist device (LVAD) of the Cleveland Clinic Foundation (CCF) is a single-chamber assist pump, driven by a high-pressure pneumatic cylinder. A low-cost, portable driver that will allow cardiac care patients, with a high-pressure pneumatic ventricle assist, more freedom of movement has been developed. The compact and light-weight configuration can provide periods of 2 h of freedom from a fixed position driver and does not use exotic technology.

  7. Pneumatic pellet injectors for TFTR and JET

    International Nuclear Information System (INIS)

    Combs, S.K.; Milora, S.L.

    1986-01-01

    This paper describes the development of pneumatic hydrogen pellet injectors for plasma fueling applications on the Tokamak Fusion Test Reactor (TFTR) and the Joint European Torus (JET). The performance parameters of these injectors represent an extension of previous experience and include pellet sizes in the range 2-6 mm in diameter and speeds approaching 2 km/s. Design features and operating characteristics of these pneumatic injectors are presented

  8. A comparison of sputum induction methods: ultrasonic vs compressed-air nebulizer and hypertonic vs isotonic saline inhalation.

    Science.gov (United States)

    Loh, L C; Eg, K P; Puspanathan, P; Tang, S P; Yip, K S; Vijayasingham, P; Thayaparan, T; Kumar, S

    2004-03-01

    Airway inflammation can be demonstrated by the modem method of sputum induction using ultrasonic nebulizer and hypertonic saline. We studied whether compressed-air nebulizer and isotonic saline which are commonly available and cost less, are as effective in inducing sputum in normal adult subjects as the above mentioned tools. Sixteen subjects underwent weekly sputum induction in the following manner: ultrasonic nebulizer (Medix Sonix 2000, Clement Clarke, UK) using hypertonic saline, ultrasonic nebulizer using isotonic saline, compressed-air nebulizer (BestNeb, Taiwan) using hypertonic saline, and compressed-air nebulizer using isotonic saline. Overall, the use of an ultrasonic nebulizer and hypertonic saline yielded significantly higher total sputum cell counts and a higher percentage of cell viability than compressed-air nebulizers and isotonic saline. With the latter, there was a trend towards squamous cell contaminations. The proportion of various sputum cell types was not significantly different between the groups, and the reproducibility in sputum macrophages and neutrophils was high (Intraclass correlation coefficient, r [95%CI]: 0.65 [0.30-0.91] and 0.58 [0.22-0.89], p compressed-air nebulizers and isotonic saline. We conclude that in normal subjects, although both nebulizers and saline types can induce sputum with reproducible cellular profile, ultrasonic nebulizers and hypertonic saline are more effective but less well tolerated.

  9. Effect that an educational program for cystic fibrosis patients and caregivers has on the contamination of home nebulizers

    Directory of Open Access Journals (Sweden)

    Adriana Della Zuana

    2014-04-01

    Full Text Available OBJECTIVE: To describe the pathogens found in home nebulizers and in respiratory samples of cystic fibrosis (CF patients, and to evaluate the effect that a standardized instruction regarding cleaning and disinfection of nebulizers has on the frequency of nebulizer contamination. METHODS: We included 40 CF patients (22 males, all of whom used the same model of nebulizer. The median patient age was 11.2 ± 3.74 years. We collected samples from the nebulizer mouthpiece and cup, using a sterile swab moistened with sterile saline. Respiratory samples were collected by asking patients to expectorate into a sterile container or with oropharyngeal swabs after cough stimulation. Cultures were performed on selective media, and bacteria were identified by classical biochemical tests. Patients received oral and written instructions regarding the cleaning and disinfection of nebulizers. All determinations were repeated an average of two months later. RESULTS: Contamination of the nebulizer (any part was detected in 23 cases (57.5%. The nebulizer mouthpiece and cup were found to be contaminated in 16 (40.0% and 19 (47.5%, respectively. After the standardized instruction had been given, there was a significant decrease in the proportion of contaminated nebulizers (43.5%. CONCLUSIONS: In our sample of CF patients, nebulizer contamination was common, indicating the need for improvement in patient practices regarding the cleaning and disinfection of their nebulizers. A one-time educational intervention could have a significant positive impact.

  10. Enhancing Mass Lesion of the Sphenoid: Atypical Presentation of Ongoing Pneumatization

    Directory of Open Access Journals (Sweden)

    Deepak Vallabhaneni

    2016-01-01

    Full Text Available Sinus pneumatization is a complex variable process that begins in early life and continues for many years. We present a case of a 6-year-old boy with progressive headaches and neurologic symptoms suggestive of intracranial pathology. The presence of enhancing tissue within the sphenoid sinus created a diagnostic dilemma which leads to a transsphenoidal biopsy. Knowledge of imaging characteristics associated with incomplete pneumatization can help differentiate it from more ominous skull base pathology and prevent unnecessary testing. We describe four-year imaging follow-up in a patient with incomplete pneumatization of the sphenoid sinus presenting as an enhancing mass lesion with subsequent follow-up imaging demonstrating gradual regression and increased aeration of the sphenoid sinus.

  11. Pneumatic wrench retains or discharges nuts or bolts as desired

    Science.gov (United States)

    Bouille, J. R.

    1966-01-01

    Pneumatic wrench grips, screws or unscrews, and discharges a nut or bolt as desired. The device consists of a standard pneumatic wrench modified with a special hex bolt head socket assembly and a diaphragm air cylinder.

  12. A pneumatic Bionic Voice prosthesis-Pre-clinical trials of controlling the voice onset and offset.

    Directory of Open Access Journals (Sweden)

    Farzaneh Ahmadi

    Full Text Available Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech.

  13. A pneumatic Bionic Voice prosthesis-Pre-clinical trials of controlling the voice onset and offset.

    Science.gov (United States)

    Ahmadi, Farzaneh; Noorian, Farzad; Novakovic, Daniel; van Schaik, André

    2018-01-01

    Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech.

  14. A pneumatic Bionic Voice prosthesis—Pre-clinical trials of controlling the voice onset and offset

    Science.gov (United States)

    Noorian, Farzad; Novakovic, Daniel; van Schaik, André

    2018-01-01

    Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech. PMID:29466455

  15. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power...

  16. Comparison of direct injection nebulizer and desolvating microconcentric nebulizer for analysis of chlorine-, bromine- and iodine-containing compounds by reversed phase HPLC with ICP-MS detection

    DEFF Research Database (Denmark)

    Jensen, B.P.; Gammelgaard, Bente; Hansen, S.H.

    2003-01-01

    the direct injection nebulizer at flow rates of 25 and 50 mul min(-1), the influence of 0-50% methanol and 0-25% acetonitrile on the sensitivity was studied. For chlorine and bromine, the relative sensitivity decreased with increasing amounts of organic solvent. For iodine, the relative sensitivity reached...... structure. Many chlorine-, bromine-, and iodine-containing compounds were partially lost in the desolvating unit. For those chlorine- and iodine-containing compounds that were not lost, the sensitivity was independent of methanol concentration in the solvent when a 0-100% methanol gradient was applied......With the purpose of finding ways to combine micro-bore reversed phase HPLC with ICP-MS detection for analysis of drug substances containing chlorine, bromine and iodine, the suitability of a direct injection nebulizer and an Aridus desolvating microconcentric nebulizer was compared. Using...

  17. Peritoneal Nebulization of Ropivacaine during Laparoscopic Cholecystectomy: Dose Finding and Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Massimo Allegri

    2017-01-01

    Full Text Available Background. Intraperitoneal nebulization of ropivacaine reduces postoperative pain and morphine consumption after laparoscopic surgery. The aim of this multicenter double-blind randomized controlled trial was to assess the efficacy of different doses and dose-related absorption of ropivacaine when nebulized in the peritoneal cavity during laparoscopic cholecystectomy. Methods. Patients were randomized to receive 50, 100, or 150 mg of ropivacaine 1% by peritoneal nebulization through a nebulizer. Morphine consumption, pain intensity in the abdomen, wound and shoulder, time to unassisted ambulation, discharge time, and adverse effects were collected during the first 48 hours after surgery. The pharmacokinetics of ropivacaine was evaluated using high performance liquid chromatography. Results. Nebulization of 50 mg of ropivacaine had the same effect of 100 or 150 mg in terms of postoperative morphine consumption, shoulder pain, postoperative nausea and vomiting, activity resumption, and hospital discharge timing (>0.05. Plasma concentrations did not reach toxic levels in any patient, and no significant differences were observed between groups (P>0.05. Conclusions. There is no enhancement in analgesic efficacy with higher doses of nebulized ropivacaine during laparoscopic cholecystectomy. When administered with a microvibration-based aerosol humidification system, the pharmacokinetics of ropivacaine is constant and maintains an adequate safety profile for each dosage tested.

  18. Toward modern inhalational bacteriophage therapy: nebulization of bacteriophages of Burkholderia cepacia complex.

    Science.gov (United States)

    Golshahi, Laleh; Seed, Kimberley D; Dennis, Jonathan J; Finlay, Warren H

    2008-12-01

    Antibiotic-resistant bacterial infections have renewed interest in finding substitute methods of treatment. The purpose of the present in vitro study was to investigate the possibility of respiratory delivery of a Burkholderia cepacia complex (BCC) bacteriophage by nebulized aerosol administration. Bacteriophages in isotonic saline were aerosolized with Pari LC star and eFlow nebulizers, at titers with mean value (standard deviation) of 2.15 x 10(8) (1.63 x 10(8)) plaque-forming unit (PFU)/mL in 2.5-mL nebulizer fills. The breathing pattern of an adult was simulated using a pulmonary waveform generator. During breath simulation, the size distributions of the nebulized aerosol were measured using phase doppler anemometry (PDA). Efficiency of nebulizer delivery was subsequently determined by collection of aerosol on low resistance filters and measurement of bacteriophage titers. These filter titers were used as input data to a mathematical lung deposition model to predict regional deposition of bacteriophages in the lung and initial bacteriophage titers in the liquid surface layer of each conducting airway generation. The results suggest that BCC bacteriophages can be nebulized successfully within a reasonable delivery time and predicted titers in the lung indicate that this method may hold potential for treatment of bacterial lung infections common among cystic fibrosis patients.

  19. Muscle- and pneumatic-powered counterpulsating LVADs: a pilot study.

    Science.gov (United States)

    Wilde, J C; van Loon, J; Bishop, N D; Shelton, A D; Marten, C; Kolff, W J; Stephenson, L; Baciewicz, F; Nakajima, H; Thomas, G

    1994-03-01

    There is a worldwide interest in supporting the failing heart with a skeletal muscle by either wrapping it around the natural heart (dynamic cardiomyoplasty) or by constructing a skeletal muscle ventricle (SMV) used for counterpulsation. Conventional cardiomyoplasty in many clinics carries an operative mortality rate of 15-20% partly because it requires 6 weeks to train the muscle to contract continually. A flexible, pear-shaped blood pump with an inflatable air chamber was designed and made around which a muscle can be wrapped. The advantage of our design is that it can also be driven by pneumatic power, immediately supporting the circulation of a seriously ill patient while that patient is still on the operating table. After a period of time to allow for revascularization and the subsequent training of the muscle, the external pneumatic power can be gradually discontinued. Then the assisted patient becomes tether-free. If, at any time, the muscle power fails, the pneumatic-powered mechanism can be reactivated. In the preferred approach, the blood pump is connected to the aorta for diastolic counterpulsation. A muscle can either be wrapped around the blood pump directly, or around one of two separate muscle pouches connected to the blood pump. To facilitate surgery, a large pouch is inserted under the musculus latissimus dorsi, which is connected to a blood pump. When stimulated, the muscle will contract over the pouch compressing it and providing power to the blood pump. If it is found that the pressure generated in the pouch cannot meet the aortic blood pressure, it can be augmented by using a pressure amplifier.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Analytical evaluation of nebulizers for the introduction of acetic acid extracts aiming at the determination of trace elements by inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gois, Jefferson S. de; Maranhao, Tatiane de A. [Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-970, Florianopolis, SC (Brazil); Oliveira, Fernando J.S. [Petroleo Brasileiro S.A., Gerencia de Meio Ambiente, Rio de Janeiro, RJ (Brazil); Frescura, Vera L.A.; Curtius, Adilson J. [Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-970, Florianopolis, SC (Brazil); Borges, Daniel L.G., E-mail: daniel.borges@ufsc.br [Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-970, Florianopolis, SC (Brazil)

    2012-11-15

    , with the exception of Hg, after continuous aspiration for 70 min. The nebulization efficiency ranged from 4.6% to 64% for CF and MM nebulizers, respectively. Leaching solution from a solid waste residue was analyzed using all the studied systems in three different calibration media. In general, the results indicate that calibration solutions should be prepared in the same medium as the leachate, although for USN and MMN a reasonable agreement among the results was obtained regardless of the calibration solution used. Detection limits ranging from 0.01 {mu}g L{sup -1} to 2 {mu}g L{sup -1} were obtained, with little discrepancy among the different nebulizers used. - Highlights: Black-Right-Pointing-Pointer Four distinct nebulizers were evaluated for analysis of acetic acid extracts at two pH. Black-Right-Pointing-Pointer Tolerance to low concentrations of acetic acid was observed in all systems. Black-Right-Pointing-Pointer Trace element determination in acetic acid requires specific calibration approaches.

  1. Modeling and Analysis of a Novel Pneumatic Artificial Muscle and Pneumatic Arm Exoskeleton

    OpenAIRE

    Yang, Hee Doo

    2017-01-01

    The soft robotics field is developing rapidly and is poised to have a wide impact in a variety of applications. Soft robots have intrinsic compliance, offering a number of benefits as compared to traditional rigid robots. Compliance can provide compatibility with biological systems such as the human body and can provide some benefits for human safety and control. Further research into soft robots can be advanced by further development of pneumatic actuators. Pneumatic actuators are a ...

  2. Efficacy and safety of glycopyrrolate/eFlow® CS (nebulized glycopyrrolate) in moderate-to-very-severe COPD: Results from the glycopyrrolate for obstructive lung disease via electronic nebulizer (GOLDEN) 3 and 4 randomized controlled trials.

    Science.gov (United States)

    Kerwin, Edward; Donohue, James F; Goodin, Thomas; Tosiello, Robert; Wheeler, Alistair; Ferguson, Gary T

    2017-11-01

    SUN-101 is a combination of glycopyrrolate delivered through an innovative, electronic nebulizer, intended for the treatment of patients with COPD. The objective of this study was to assess the efficacy and safety of this new drug device combination. Replicate Phase III randomized, double-blind, placebo-controlled studies were conducted to evaluate the efficacy and safety of glycopyrrolate solution administered by an investigational eFlow ® Closed System (eFlow ® CS) nebulizer in subjects with moderate-to-very-severe COPD, including those with continued background use of a long-acting beta 2 -agonist ± inhaled corticosteroid and/or history of cardiovascular (CV) disease. Subjects were randomized in a 1:1:1 ratio to receive placebo or glycopyrrolate (25 μg or 50 μg twice daily [BID]) for 12 weeks. The primary efficacy endpoint was the change from baseline in trough forced expiratory volume in 1 s (FEV 1 ) at Week 12 compared with placebo. Secondary endpoints included change from baseline in forced vital capacity (FVC) after 12 weeks, change from baseline in health status measured by St George's Respiratory Questionnaire (SGRQ) at 12 weeks/end of study (EOS), and change in rescue medication use, as well as change from baseline in FEV 1 area under the curve from 0 to 12 h after 12 weeks in the GOLDEN 3 sub-study. Daytime and night-time symptoms were recorded using an electronic diary. Safety was monitored throughout the study, including major adverse cardiovascular events. A total of 653 subjects were randomized in GOLDEN 3 and 641 in GOLDEN 4. Treatment with glycopyrrolate 25 μg BID and 50 μg BID resulted in statistically significant and clinically important changes from baseline in trough FEV 1 compared with placebo at Week 12 (GOLDEN 3: 0.105 L and 0.126 L; p ≤ 0.0001; GOLDEN 4: 0.084 L and 0.082 L; p ≤ 0.0001). Nebulized glycopyrrolate 25 μg BID and 50 μg BID also resulted in improvements in FVC change from baseline versus placebo at

  3. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria.

    Directory of Open Access Journals (Sweden)

    Akinobu Watanabe

    Full Text Available Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT imaging. Complementary examination of external and internal osteology reveals (1 highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2 anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3 apneumatic sacral vertebrae; and (4 a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  4. Enhancing in situ bioremediation with pneumatic fracturing

    International Nuclear Information System (INIS)

    Anderson, D.B.; Peyton, B.M.; Liskowitz, J.L.; Fitzgerald, C.; Schuring, J.R.

    1994-04-01

    A major technical obstacle affecting the application of in situ bioremediation is the effective distribution of nutrients to the subsurface media. Pneumatic fracturing can increase the permeability of subsurface formations through the injection of high pressure air to create horizontal fracture planes, thus enhancing macro-scale mass-transfer processes. Pneumatic fracturing technology was demonstrated at two field sites at Tinker Air Force Base, Oklahoma City, Oklahoma. Tests were performed to increase the permeability for more effective bioventing, and evaluated the potential to increase permeability and recovery of free product in low permeability soils consisting of fine grain silts, clays, and sedimentary rock. Pneumatic fracturing significantly improved formation permeability by enhancing secondary permeability and by promoting removal of excess soil moisture from the unsaturated zone. Postfracture airflows were 500% to 1,700% higher than prefracture airflows for specific fractured intervals in the formation. This corresponds to an average prefracturing permeability of 0.017 Darcy, increasing to an average of 0.32 Darcy after fracturing. Pneumatic fracturing also increased free-product recovery rates of number 2 fuel from an average of 587 L (155 gal) per month before fracturing to 1,647 L (435 gal) per month after fracturing

  5. Endoscopic Pneumatic Dilation for Esophageal Achalasia.

    Science.gov (United States)

    Markar, Sheraz; Zaninotto, Giovanni

    2018-04-01

    Pneumatic dilation is a well-established treatment modality that has withstood the test of time. Prospective and randomized trials have shown that in expert hands, it provides results similar to a laparoscopic Heller myotomy with fundoplication. In addition, it should be considered the primary form of treatment in patients who experience recurrence of symptoms after a surgical myotomy.

  6. Pneumatic pellet injector for JT-60

    International Nuclear Information System (INIS)

    Onozuka, Masanori; Hiratsuka, Hajime; Kawasaki, Kouzo.

    1990-01-01

    The pneumatic 4-shot pellet injector has been installed and operated for JT-60 (JAERI Tokamak-60). The performance tests have proven that the device provides high speed pellets as planned. The maximum pellet velocity obtained in the hydrogen pellet tests is greater than 2.3km/s at 100 bar propellant gas. (author)

  7. Pneumatic pellet injector for JT-60

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, Masanori (Mitsubishi Heavy Industries Ltd., Tokyo (Japan)); Hiratsuka, Hajime; Kawasaki, Kouzo

    1990-11-01

    The pneumatic 4-shot pellet injector has been installed and operated for JT-60 (JAERI Tokamak-60). The performance tests have proven that the device provides high speed pellets as planned. The maximum pellet velocity obtained in the hydrogen pellet tests is greater than 2.3km/s at 100 bar propellant gas. (author).

  8. Pneumatic devices in isotope technology. Pt. 1

    International Nuclear Information System (INIS)

    Egri, B.; Csoeke, A.

    1974-01-01

    A detailed survey has been given about the following pneumatic devices used in the isotope technology: working cylinders, membrane motors, valves, detectors, hydropneumatic units. The characteristics of the units of various control systems have been described in tables. (K.A.)

  9. Soft pneumatic grippers embedded with stretchable electroadhesion

    Science.gov (United States)

    Guo, J.; Elgeneidy, K.; Xiang, C.; Lohse, N.; Justham, L.; Rossiter, J.

    2018-05-01

    Current soft pneumatic grippers cannot robustly grasp flat materials and flexible objects on curved surfaces without distorting them. Current electroadhesive grippers, on the other hand, are difficult to actively deform to complex shapes to pick up free-form surfaces or objects. An easy-to-implement PneuEA gripper is proposed by the integration of an electroadhesive gripper and a two-fingered soft pneumatic gripper. The electroadhesive gripper was fabricated by segmenting a soft conductive silicon sheet into a two-part electrode design and embedding it in a soft dielectric elastomer. The two-fingered soft pneumatic gripper was manufactured using a standard soft lithography approach. This novel integration has combined the benefits of both the electroadhesive and soft pneumatic grippers. As a result, the proposed PneuEA gripper was not only able to pick-and-place flat and flexible materials such as a porous cloth but also delicate objects such as a light bulb. By combining two soft touch sensors with the electroadhesive, an intelligent and shape-adaptive PneuEA material handling system has been developed. This work is expected to widen the applications of both soft gripper and electroadhesion technologies.

  10. Improving dynamic performances of PWM-driven servo-pneumatic systems via a novel pneumatic circuit.

    Science.gov (United States)

    Taghizadeh, Mostafa; Ghaffari, Ali; Najafi, Farid

    2009-10-01

    In this paper, the effect of pneumatic circuit design on the input-output behavior of PWM-driven servo-pneumatic systems is investigated and their control performances are improved using linear controllers instead of complex and costly nonlinear ones. Generally, servo-pneumatic systems are well known for their nonlinear behavior. However, PWM-driven servo-pneumatic systems have the advantage of flexibility in the design of pneumatic circuits which affects the input-output linearity of the whole system. A simple pneumatic circuit with only one fast switching valve is designed which leads to a quasi-linear input-output relation. The quasi-linear behavior of the proposed circuit is verified both experimentally and by simulations. Closed loop position control experiments are then carried out using linear P- and PD-controllers. Since the output position is noisy and cannot be directly differentiated, a Kalman filter is designed to estimate the velocity of the cylinder. Highly improved tracking performances are obtained using these linear controllers, compared to previous works with nonlinear controllers.

  11. Short torch design for direct liquid sample introduction using conventional and micro-nebulizers for plasma spectrometry

    Science.gov (United States)

    Montaser, Akbar [Potomac, MD; Westphal, Craig S [Landenberg, PA; Kahen, Kaveh [Montgomery Village, MD; Rutkowski, William F [Arlington, VA

    2008-01-08

    An apparatus and method for providing direct liquid sample introduction using a nebulizer are provided. The apparatus and method include a short torch having an inner tube and an outer tube, and an elongated adapter having a cavity for receiving the nebulizer and positioning a nozzle tip of the nebulizer a predetermined distance from a tip of the outer tube of the short torch. The predetermined distance is preferably about 2-5 mm.

  12. Minimizing variability of cascade impaction measurements in inhalers and nebulizers.

    Science.gov (United States)

    Bonam, Matthew; Christopher, David; Cipolla, David; Donovan, Brent; Goodwin, David; Holmes, Susan; Lyapustina, Svetlana; Mitchell, Jolyon; Nichols, Steve; Pettersson, Gunilla; Quale, Chris; Rao, Nagaraja; Singh, Dilraj; Tougas, Terrence; Van Oort, Mike; Walther, Bernd; Wyka, Bruce

    2008-01-01

    The purpose of this article is to catalogue in a systematic way the available information about factors that may influence the outcome and variability of cascade impactor (CI) measurements of pharmaceutical aerosols for inhalation, such as those obtained from metered dose inhalers (MDIs), dry powder inhalers (DPIs) or products for nebulization; and to suggest ways to minimize the influence of such factors. To accomplish this task, the authors constructed a cause-and-effect Ishikawa diagram for a CI measurement and considered the influence of each root cause based on industry experience and thorough literature review. The results illustrate the intricate network of underlying causes of CI variability, with the potential for several multi-way statistical interactions. It was also found that significantly more quantitative information exists about impactor-related causes than about operator-derived influences, the contribution of drug assay methodology and product-related causes, suggesting a need for further research in those areas. The understanding and awareness of all these factors should aid in the development of optimized CI methods and appropriate quality control measures for aerodynamic particle size distribution (APSD) of pharmaceutical aerosols, in line with the current regulatory initiatives involving quality-by-design (QbD).

  13. Surface acoustic wave nebulization facilitating lipid mass spectrometric analysis.

    Science.gov (United States)

    Yoon, Sung Hwan; Huang, Yue; Edgar, J Scott; Ting, Ying S; Heron, Scott R; Kao, Yuchieh; Li, Yanyan; Masselon, Christophe D; Ernst, Robert K; Goodlett, David R

    2012-08-07

    Surface acoustic wave nebulization (SAWN) is a novel method to transfer nonvolatile analytes directly from the aqueous phase to the gas phase for mass spectrometric analysis. The lower ion energetics of SAWN and its planar nature make it appealing for analytically challenging lipid samples. This challenge is a result of their amphipathic nature, labile nature, and tendency to form aggregates, which readily precipitate clogging capillaries used for electrospray ionization (ESI). Here, we report the use of SAWN to characterize the complex glycolipid, lipid A, which serves as the membrane anchor component of lipopolysaccharide (LPS) and has a pronounced tendency to clog nano-ESI capillaries. We also show that unlike ESI SAWN is capable of ionizing labile phospholipids without fragmentation. Lastly, we compare the ease of use of SAWN to the more conventional infusion-based ESI methods and demonstrate the ability to generate higher order tandem mass spectral data of lipid A for automated structure assignment using our previously reported hierarchical tandem mass spectrometry (HiTMS) algorithm. The ease of generating SAWN-MS(n) data combined with HiTMS interpretation offers the potential for high throughput lipid A structure analysis.

  14. Bubble inductors: Pneumatic tuning of a stretchable inductor

    Science.gov (United States)

    Lazarus, Nathan; Bedair, Sarah S.

    2018-05-01

    From adaptive matching networks in power systems to channel selectable RF filters and circuitry, tunable inductors are fundamental components for circuits requiring reconfigurability. Here we demonstrate a new continuously tunable inductor based on physically stretching the inductor traces themselves. Liquid-metal-based stretchable conductors are wrapped around a pneumatic bubble actuator, allowing the inductor to be collapsed or expanded by application of pressure. In vacuum the bubble collapses, bringing the loop area to nearly zero, while positive pressure brings a dramatic increase in area and loop inductance. Using this approach, the inductor demonstrated in this work was able to achieve a tuning ratio of 2.6 with 1-2 second response time. With conductors available that can stretch by hundreds of percent, this technique is promising for very large tuning ratios in continuously tunable inductors.

  15. 3-D pneumatic seismic isolation of nuclear power plants

    International Nuclear Information System (INIS)

    Beliaev, V.S.; Vinogradov, V.V.; Kostarev, V.V.; Kuzmitchev, V.P.; Privalov, S.A.; Siro, V.A.; Krylova, I.N.; Dolgaya, A.A.; Uzdin, A.M.; Vasiliev, A.V.

    2002-01-01

    This paper describes the work carried at the Russian Federation Research Center of Fundamental Engineering (RCFE), in development of innovative pneumatic multicomponent low-frequency seismic isolation bearings for advanced nuclear power plants.This device incorporates both supporting spherical elements, which provide displacements in the horizontal direction, and pneumatic dampers with rubber diaphragms for displacement in the vertical direction. To decrease the relative displacements of the isolated object the system uses viscoelastic dampers. Damping devices had been specially elaborated for the reactor building seismic isolation system as a result of substantial advances in the design and operation of the HD-type hydrodampers, created at the CKTI VIBROSEISM. The procedures developed have been used for comparison of the test and computer data on model isolated steel structure (MISS) and isolated rigid mass (IRM) isolators produced by ENEA and KAERI. Most recent work has concentrated on the development of mathematical models of isolators and isolated nuclear structures. Force-deformation characteristics of the HDRB model had been calculated on the basis of a special method of non-linear elastic theory using the continual transformations method. (author)

  16. Repeating pneumatic hydrogen pellet injector for plasma fueling

    International Nuclear Information System (INIS)

    Combs, S.K.; Milora, S.L.; Foust, C.R.; Foster, C.A.; Schuresko, D.D.

    1985-01-01

    A repeating pneumatic pellet injector has been developed for plasma fueling applications. The repetitive device extends pneumatic injector operation to steady state. The active mechanism consists of an extruder and a gun assembly that are cooled by flowing liquid-helium refrigerant. The extruder provides a continuous supply of solid hydrogen to the gun assembly, where a reciprocating gun barrel forms and chambers cylindrical pellet from the extrusion; pellets are then accelerated with compressed hydrogen gas (pressures up to 125 bar) to velocities -1 have been obtained with 2.1- , 3.4- , and 4.0-mm-diameter pellets. The present apparatus operates at higher firing rates in short bursts; for example, a rate of 6 s -1 for 2 s with the larger pellets. These pellet parameters are in the range applicable for fueling large present-day fusion devices such as the Tokamak Fusion Test Reactor (TFTR). Experimental results are presented, including effects of propellant pressure and barrel length on gun performance

  17. Key considerations on nebulization of antimicrobial agents to mechanically ventilated patients.

    Science.gov (United States)

    Rello, J; Rouby, J J; Sole-Lleonart, C; Chastre, J; Blot, S; Luyt, C E; Riera, J; Vos, M C; Monsel, A; Dhanani, J; Roberts, J A

    2017-09-01

    Nebulized antibiotics have an established role in patients with cystic fibrosis or bronchiectasis. Their potential benefit to treat respiratory infections in mechanically ventilated patients is receiving increasing interest. In this consensus statement of the European Society of Clinical Microbiology and Infectious Diseases, the body of evidence of the therapeutic utility of aerosolized antibiotics in mechanically ventilated patients was reviewed and resulted in the following recommendations: Vibrating-mesh nebulizers should be preferred to jet or ultrasonic nebulizers. To decrease turbulence and limit circuit and tracheobronchial deposition, we recommend: (a) the use of specifically designed respiratory circuits avoiding sharp angles and characterized by smooth inner surfaces, (b) the use of specific ventilator settings during nebulization including use of a volume controlled mode using constant inspiratory flow, tidal volume 8 mL/kg, respiratory frequency 12 to 15 bpm, inspiratory:expiratory ratio 50%, inspiratory pause 20% and positive end-expiratory pressure 5 to 10 cm H 2 O and (c) the administration of a short-acting sedative agent if coordination between the patient and the ventilator is not obtained, to avoid patient's flow triggering and episodes of peak decelerating inspiratory flow. A filter should be inserted on the expiratory limb to protect the ventilator flow device and changed between each nebulization to avoid expiratory flow obstruction. A heat and moisture exchanger and/or conventional heated humidifier should be stopped during the nebulization period to avoid a massive loss of aerosolized particles through trapping and condensation. If these technical requirements are not followed, there is a high risk of treatment failure and adverse events in mechanically ventilated patients receiving nebulized antibiotics for pneumonia. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights

  18. The efficacy of nebulized magnesium sulfate alone and in combination with salbutamol in acute asthma

    Directory of Open Access Journals (Sweden)

    Sarhan HA

    2016-06-01

    Full Text Available Hatem A Sarhan,1 Omar H EL-Garhy,1 Mohamed A Ali,2 Nouran A Youssef1 1Department of Pharmaceutics, Faculty of Pharmacy, 2Department of Chest Diseases, Faculty of Medicine, Minia University, Minia, Egypt Objective: Evaluation of the efficacy of nebulized magnesium sulfate (MgSO4 alone and in combination with salbutamol in acute asthma.Methods: A double-blind randomized controlled study was conducted in Chest and Emergency Departments. Thirty patients of acute attack of bronchial asthma were randomized into three groups: MgSO4 nebulization (group A, salbutamol nebulization (group B, and their combination (group C. All patients were monitored before and after nebulization (each 20 minutes for peak expiratory flow rate (PEFR, respiratory rate (RR, heart rate (HR, blood pressure, pulsus paradoxus, oxygen saturation, clinical examination, and Fischl index.Results: A highly significant improvement in PEFR, PEFR percentage, and Fischl index and significant decrease in RR and HR was observed in all groups. A similar improvement in PEFR was observed in group A and group B (P=0.389. The difference in peak expiratory flow (PEF improvement was insignificant between group B and group C (P=0.101, while there was a significant differ­ence between group A and group C (P=0.014 in favor of group C.Conclusion: Nebulized MgSO4 alone or combined with salbutamol has a clinically significant bronchodilator effect in acute asthma and leads to clinical improvement, increase in PEFR, reduction in HR, and reduction in RR. The response to nebulized MgSO4 alone (PEFR improvement 54±35.6 L/min, P=0.001 is comparable (P=0.389 to that of nebulized salbutamol (PEFR improvement 67.0±41.9 L/min, P=0.001 and is significantly less than (P=0.014 that of nebulized combination (PEFR improvement 92.0±26.9 L/min, P=0.000. Keywords: nebulized magnesium sulfate, salbutamol, acute asthma, peak expiratory flow rate, Fischl index

  19. Pharmacokinetics of nebulized and subcutaneously implanted terbinafine in cottonmouths (Agkistrodon piscivorus).

    Science.gov (United States)

    Kane, L P; Allender, M C; Archer, G; Leister, K; Rzadkowska, M; Boers, K; Souza, M; Cox, S

    2017-10-01

    Ophidiomyces ophiodiicola, the causative agent of snake fungal disease, is proposed as a serious threat to the conservation of several snake populations. The objective of this study was to determine the pharmacokinetic parameters of terbinafine administered through nebulization and a sustained subcutaneous implant as potential treatments of Ophidiomyces in reptiles. Seven adult cottonmouths (Agkistrodon piscivorus) were used in single-dose trials. Each snake was nebulized with terbinafine (2 mg/ml) for 30 min and had blood collected before nebulization and up to 12 hr after nebulization. Following a 5-month washout, the same snakes were administered a subcutaneous implant containing 24.5 mg terbinafine; blood was collected at baseline, 1 day postimplant placement, and then once weekly for 9 weeks. Plasma for both studies was analyzed by high-performance liquid chromatography. The mean plasma concentrations of nebulized terbinafine peaked between 0.5 and 4 hr. The subcutaneously implanted terbinafine reached therapeutic concentrations on day 1 and maintained therapeutic for over 6 weeks. These methods and doses are recommended as potential treatment options for snake fungal disease in reptiles. © 2017 John Wiley & Sons Ltd.

  20. Slit Tubes for Semisoft Pneumatic Actuators.

    Science.gov (United States)

    Belding, Lee; Baytekin, Bilge; Baytekin, Hasan Tarik; Rothemund, Philipp; Verma, Mohit S; Nemiroski, Alex; Sameoto, Dan; Grzybowski, Bartosz A; Whitesides, George M

    2018-03-01

    This article describes a new principle for designing soft or 'semisoft' pneumatic actuators: SLiT (for SLit-in-Tube) actuators. Inflating an elastomeric balloon, when enclosed by an external shell (a material with higher Young's modulus) containing slits of different directions and lengths, produces a variety of motions, including bending, twisting, contraction, and elongation. The requisite pressure for actuation depends on the length of the slits, and this dependence allows sequential actuation by controlling the applied pressure. Different actuators can also be controlled using external "sliders" that act as reprogrammable "on-off" switches. A pneumatic arm and a walker constructed from SLiT actuators demonstrate their ease of fabrication and the range of motions they can achieve. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  2. A pneumatic cylinder driving polyhedron mobile mechanism

    Science.gov (United States)

    Ding, Wan; Kim, Sung-Chan; Yao, Yan-An

    2012-03-01

    A novel pneumatic cylinder driving polyhedron mobile mechanism is proposed in this paper. The mechanism is comprised of 5 tetrahedrons which includes a pneumatic cylinder in each edge. It locomotes by rolling and the rolling principle refers to the center of mass (CM) of the mechanism moved out of the supporting area and let it tip over through the controlling of the motion sequence of these cylinders. Firstly, the mathematical model is built to analysis the relation between the configuration and the CM of the mechanism. Then, a binary control strategy is developed to simplify and improve the control of this mobile mechanism. After that, dynamic simulation is performed to testify the analytical validity and feasibility of the rolling gaits. At last, a prototype is fabricated to achieve the rolling successfully to demonstrate the proposed concept.

  3. Pneumatic Muscle Actuated Compliant Gripper Systems

    Directory of Open Access Journals (Sweden)

    Deaconescu Andrea

    2016-01-01

    Full Text Available The paper presents the stages of developing new, light, eco-friendly and bionic gripper systems. Gripping is achieved by means of original, self adaptive, bio-inspired systems, with a pneumatic muscle as motion generator. The method underlying the development of these new gripping systems is based on the creation of concepts by analogy, an instrument aimed at widening the inspiration horizon in designing by using models from nature.

  4. Pneumatic Muscle Actuated Compliant Gripper Systems

    OpenAIRE

    Deaconescu Andrea

    2016-01-01

    The paper presents the stages of developing new, light, eco-friendly and bionic gripper systems. Gripping is achieved by means of original, self adaptive, bio-inspired systems, with a pneumatic muscle as motion generator. The method underlying the development of these new gripping systems is based on the creation of concepts by analogy, an instrument aimed at widening the inspiration horizon in designing by using models from nature.

  5. Design evaluaion: pneumatic transport and classification

    International Nuclear Information System (INIS)

    McNair, J.M.

    1979-10-01

    This report describes the evaluation of selected design features of the cold engineering scale pneumatic transport and classification subsystems used in the development of the head-end equipment for HTGR fuel reprocessing. The report identifies areas that require further design effort and evaluation of alternatives prior to the design of the HTGR reference recycle facility (HRRF). Seven areas in the transport subsystem and three in the classification subsystem were selected for evaluation. Seventeen specific recommendations are presented for further design effort

  6. Predictors of treatment failure for pneumatic retinopexy.

    Science.gov (United States)

    Rootman, Dan B; Luu, Shelly; M Conti, Stephen; Mandell, Mark; Devenyi, Robert; Lam, Wai-Ching; Kertes, Peter J

    2013-12-01

    The purpose of this study was to define the overall anatomic success rate in pneumatic retinopexy and to identify morphologic features that may be predictive of treatment failure in pneumatic retinopexy. Prospective consecutive interventional case series of patients with new-onset primary rhegmatogenous retinal detachments treated with pneumatic retinopexy. In this interventional case series, consecutive patients with new-onset primary rhegmatogenous retinal detachments were treated with pneumatic retinopexy and followed prospectively. Morphologic data were collected on 3-colour fundus drawings. The primary outcome measure was treatment failure, defined as requirement for scleral buckle or vitrectomy within the follow-up period. Rates of failure for each morphologic feature were compared and a logistic regression model was fit. A total of 113 eyes were included in the study. Anatomic success was achieved in 69.6% of patients. Morphologic criteria including the position and number of breaks, position and extent of lattice degeneration, size of the detached area, and macular status were all found not to be significantly related to failure. In multivariate analysis, only 3 predictors, pseudophakic status (p < 0.05, odds ratio [OR] 2.9, 95% CI, 1.06-7.88), presence of retinal break greater than 1 clock-hour (p < 0.05, OR 3.41, 1.06-11.02), and presence of grade C or D proliferative vitreoretinopathy (PVR) (p < 0.01, OR 31.83, 95% CI, 3.59-282.24), gained statistical significance. Only pseudophakia, a large retinal break, and/or PVR was associated with an increased likelihood of failure. Copyright © 2013 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  7. Microcolumn high pressure liquid chromatography with a glass-frit nebulizer interface for plasma emission detection

    International Nuclear Information System (INIS)

    Ibrahim, M.; Nisamaneepong, W.; Caruso, J.

    1985-01-01

    Microcolumn high pressure liquid chromatography (micro-HPLC) is rapidly gaining recognition as a practical separation tool for organometallic compounds. The use of the inductively coupled plasma (ICP) as a detector for micro-HPLC is studied. Several miniaturized glass-frit nebulizers are investigated as interfaces between the output of the microbore column and the ICP torch. Their performance with aqueous and methanolic solutions is evaluated by direct nebulization and flow injection analysis. The most efficient of these nebulizers is used in the micro-HPLC/ICP study of some Cd, Pb, and Zn organometallic compounds. Detection limits of 1.92 ng of Pb for tetramethyllead and 5.01 ng of Pb for tetraethyllead are obtained and compared with regular HPLC/ICP of these same compounds. Approximately equivalent detection limits were obtained when using a microwave induced plasma as an alternate plasma source

  8. Deep sedation during pneumatic reduction of intussusception.

    Science.gov (United States)

    Ilivitzki, Anat; Shtark, Luda Glozman; Arish, Karin; Engel, Ahuva

    2012-05-01

    Pneumatic reduction of intussusception under fluoroscopic guidance is a routine procedure. The unsedated child may resist the procedure, which may lengthen its duration and increase the radiation dose. We use deep sedation during the procedure to overcome these difficulties. The purpose of this study was to summarize our experience with deep sedation during fluoroscopic reduction of intussusception and assess the added value and complication rate of deep sedation. All children with intussusception who underwent pneumatic reduction in our hospital between January 2004 and June 2011 were included in this retrospective study. Anesthetists sedated the children using propofol. The fluoroscopic studies, ultrasound (US) studies and the childrens' charts were reviewed. One hundred thirty-one attempted reductions were performed in 119 children, of which 121 (92%) were successful and 10 (8%) failed. Two perforations (1.5%) occurred during attempted reduction. Average fluoroscopic time was 1.5 minutes. No complication to sedation was recorded. Deep sedation with propofol did not add any complication to the pneumatic reduction. The fluoroscopic time was short. The success rate of reduction was high,raising the possibility that sedation is beneficial, possibly by smooth muscle relaxation.

  9. ICP-MS nebulizer performance for analysis of SRS high salt simulated radioactive waste tank solutions (number-sign 3053)

    International Nuclear Information System (INIS)

    Jones, V.D.

    1997-01-01

    High Level Radioactive Waste Tanks at the Savannah River Site are high in salt content. The cross-flow nebulizer provided the most stable signal for all salt matrices with the smallest signal loss/suppression due to this matrix. The DIN exhibited a serious lack of tolerance for TDS; possibly due to physical de-tuning of the nebulizer efficiency

  10. Fractional-Order Control of Pneumatic Position Servosystems

    OpenAIRE

    Junyi, Cao; Binggang, Cao

    2011-01-01

    A fractional-order control strategy for pneumatic position servosystem is presented in this paper. The idea of the fractional calculus application to control theory was introduced in many works, and its advantages were proved. However, the realization of fractional-order controllers for pneumatic position servosystems has not been investigated. Based on the relationship between the pressure in cylinder and the rate of mass flow into the cylinder, the dynamic model of pneumatic position servo ...

  11. Effects of peritoneal ropivacaine nebulization for pain control after laparoscopic gynecologic surgery.

    Science.gov (United States)

    Somaini, Marta; Brambillasca, Pietro; Ingelmo, Pablo Mauricio; Lovisari, Federica; Catenacci, Stefano Scalia; Rossini, Valeria; Bucciero, Mario; Sahillioglu, Emre; Buda, Alessandro; Signorelli, Mauro; Gili, Mauro; Joshi, Girish; Fumagalli, Roberto; Ferland, Catherine E; Diemunsch, Pierre

    2014-01-01

    To evaluate the effects of peritoneal cold nebulization of ropivacaine on pain control after gynecologic laparoscopy. Evidence obtained from a properly designed, randomized, double-blind, placebo-controlled trial (Canadian Task Force classification I). Tertiary care center. One hundred thirty-five women with American Society of Anesthesiologists disease classified as ASA I-III who were scheduled to undergo operative laparoscopy. Patients were randomized to receive either nebulization of 30 mg ropivacaine before surgery (preoperative group), nebulization of 30 mg ropivacaine after surgery (postoperative group), instillation of 100 mg ropivacaine before surgery (instillation group), or instillation of saline solution (control group). Nebulization was performed using the Aeroneb Pro device. Pain scores, morphine consumption, and ambulation time were collected in the post-anesthesia care unit and at 4, 6, and 24 hours postoperatively. One hundred eighteen patients completed the study. Patients in the preoperative group reported lower pain Numeric Ranking Scale values compared with those in the control group (net difference 2 points; 95% confidence interval [CI], 0.3-3.1 at 4 hours, 1-3 at 6 hours, and 0.7-3 at 24 hours; p = .01) Patients in the preoperative group consumed significantly less morphine than did those in the control group (net difference 7 mg; 95% CI, 0.7-13; p = .02). More patients who received nebulization walked without assistance within 12 hours after awakening than did those in the instillation and control groups (net difference 15%; 95% CI, 6%-24%; p = .001). Cold nebulization of ropivacaine before surgery reduced postoperative pain and morphine consumption and was associated with earlier walking without assistance. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  12. Comparison of Pneumatic Dilation with Pneumatic Dilation Plus Botulinum Toxin for Treatment of Achalasia

    Directory of Open Access Journals (Sweden)

    Alireza Bakhshipour

    2010-03-01

    Full Text Available Among the therapeutic options for achalasia are pneumatic dilatation (PD, an appropriate long-term therapy, and botulinum toxin injection (BT that is a relatively short-term therapy. This study aimed to compare therapeutic effect of repetitive pneumatic dilation with a combined method (botulinum toxin injection and pneumatic dilation in a group of achalasia patients who are low responder to two initial pneumatic dilations. Thirty- four patients with documented primary achalasia that had low response to two times PD (<50% decrease in symptom score and barium height at 5 minute in timed esophagogram after 3month of late PD were randomized to receive pneumatic dilation (n=18 or botulinum toxin injection and pneumatic dilation by four weeks interval (n=16, PD and BT+PD groups respectively. Symptom scores were evaluated before and at 1, 6 and 12 months after treatment. Clinical remission was defined as a decrease in symptom score ≥ 50% of baseline. There were no significant differences between the two groups in gender, age and achalasia type. Remission rate of patients in BT-PD group in comparison with PD group were 87.5% vs. 67.1% (P = 0.7, 87.5% vs. 61.1% (P = 0.59 and 87.5% vs. 55.5% (P = 0.53 at 1, 6 and 12 months respectively .There were no major complications in either group. The mean symptom score decreased by 62.71% in the BT-PD group (P < 0.002 and 50.77% in the PD group (P < 0.01 at the end of the first year. Despite a better response rate in BT+PD group, a difference was not statistically significant. A difference may be meaningful if a large numbers of patients are included in the study.

  13. Physics-Based Pneumatic Hammer Instability Model, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Florida Turbine Technologies (FTT) proposes to conduct research necessary to develop a physics-based pneumatic hammer instability model for hydrostatic bearings...

  14. Measurement of elemental speciation by liquid chromatography -- inductively coupled plasma mass spectrometry (LC-ICP-MS) with the direct injection nebulizer (DIN)

    Energy Technology Data Exchange (ETDEWEB)

    Shum, Sam [Iowa State Univ., Ames, IA (United States)

    1993-05-01

    This thesis is divided into 4 parts: elemental speciation, speciation of mercury and lead compounds by microbore column LC-ICP-MS with direct injection nebulization, spatially resolved measurements of size and velocity distributions of aerosol droplets from a direct injection nebulizer, and elemental speciation by anion exchange and size exclusion chromatography with detection by ICP-MS with direct injection nebulization.

  15. Role of nebulized glycopyrrolate in the treatment of chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Santus P

    2017-11-01

    Full Text Available Pierachille Santus,1 Dejan Radovanovic,1 Andrea Cristiano,1 Vincenzo Valenti,2 Maurizio Rizzi1 1Department of Biomedical and Clinical Sciences (DIBIC, University of Milan, Division of Respiratory Diseases, “L. Sacco” Hospital, ASST Fatebenefratelli Sacco, Milan, Italy; 2Department of Health Bioscience, University of Milan – Respiratory Unit, Policlinico di San Donato, IRCCS – San Donato Milanese, Milan, Italy Abstract: In the upcoming years, the proportion of elderly patients with chronic obstructive pulmonary disease (COPD will increase, according to the progressively aging population and the increased efficacy of the pharmacological treatments, especially considering the management of chronic comorbidities. The issue to prescribe an appropriate inhalation therapy to COPD patients with significant handling or coordination difficulties represents a common clinical experience; in the latter case, the choice of an inadequate inhalation device may jeopardize the adherence to the treatment and eventually lead to its ineffectiveness. Treatment options that do not require particular timing for coordination between activation and/or inhalation or require high flow thresholds to be activated should represent the best treatment option for these patients. Nebulized bronchodilators, usually used only in acute conditions such as COPD exacerbations, could fulfill this gap, enabling an adequate drug administration during tidal breathing and without the need for patients’ cooperation. However, so far, only short-acting muscarinic antagonists have been available for nebulization. Recently, a nebulized formulation of the inhaled long-acting muscarinic antagonist glycopyrrolate, delivered by means of a novel proprietary vibrating mesh nebulizer closed system (SUN-101/eFlow®, has progressed to Phase III trials and is currently in late-stage development as an option for maintenance treatment in COPD. The present critical review describes the current

  16. Pneumatic stepper motor and device comprising at least one such pneumatic stepper motor

    NARCIS (Netherlands)

    Groenhuis, Vincent; Siepel, Françoise Jeanette; Stramigioli, Stefano

    2018-01-01

    The invention relates to a pneumatic stepper motor, comprising: - a housing, said housing accommodating at least part of: - a rack or geared axle comprising a plurality of gear elements; and - two pistons, each comprising at least two teeth, said pistons being arranged to cooperate with said rack or

  17. ULTRASONIC NEBULIZATION AND ARSENIC VALENCE STATE CONSIDERATIONS PRIOR TO DETERMINATION VIA INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

    Science.gov (United States)

    An ultrasonic nebulizer (USN) was utilized as a sample introduction device for an inductively coupled plasma mass spectrometer in an attempt to increase the sensitivity for As. The USN produced a valence state response difference for As. The As response was suppressed approximate...

  18. Promoting adherence to nebulized therapy in cystic fibrosis: poster development and a qualitative exploration of adherence.

    Science.gov (United States)

    Jones, Stephen; Babiker, Nathan; Gardner, Emma; Royle, Jane; Curley, Rachael; Hoo, Zhe Hui; Wildman, Martin J

    2015-01-01

    Cystic fibrosis (CF) health care professionals recognize the need to motivate people with CF to adhere to nebulizer treatments, yet little is known about how best to achieve this. We aimed to produce motivational posters to support nebulizer adherence by using social marketing involving people with CF in the development of those posters. The Sheffield CF multidisciplinary team produced preliminary ideas that were elaborated upon with semi-structured interviews among people with CF to explore barriers and facilitators to the use of nebulized therapy. Initial themes and poster designs were refined using an online focus group to finalize the poster designs. People with CF preferred aspirational posters describing what could be achieved through adherence in contrast to posters that highlighted the adverse consequences of nonadherence. A total of 14 posters were produced through this process. People with CF can be engaged to develop promotional material to support adherence, providing a unique perspective differing from that of the CF multidisciplinary team. Further research is needed to evaluate the effectiveness of these posters to support nebulizer adherence.

  19. Sinuclean Nebules treatment in children suffering from otitis media with effusion.

    Science.gov (United States)

    Varricchio, A; De Lucia, A; Varricchio, A M; Della Volpe, A; Mansi, N; Pastore, V; Ciprandi, G

    2017-03-01

    Otitis media with effusion (OME) is an ear disorder defined by the presence of fluid in the middle ear without signs or symptoms of acute infection. The current randomized, double-blind, controlled study aimed to evaluate whether Sinuclean Nebules treatment, administered by nasal douche (Rinowash), could induce ear healing better than isotonic saline in children with OME. The study was randomized, double-blind, and controlled. Group A (30 children) was treated with Sinuclean Nebules 45 and Group B (31 children) was treated with isotonic saline; both compounds were administered by nasal nebulization with Rinowash nasal douche twice/day in the morning and in the evening for 10 days, followed by a one-week suspension, and after by a second course as the first. Tympanogram and audiometry were performed at baseline and after treatment. Considering the global evaluation of the treatment: in Group A, 28 (93.3%) patients had complete resolution and 2 (6.7%) had partial resolution; in Group B, all patients had failure of treatment. There was a significant difference between groups (p < 0.0001). The current randomized-controlled study demonstrated that Sinuclean Nebules was effective and in the treatment of children with OME. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Characterization of the radioaerosol sup(99m)Tc-DTPA produced by different nebulizers

    International Nuclear Information System (INIS)

    Medeiros, R.B.; Nery, L.E.; Tabacniks, M.H.

    1991-01-01

    Our aim was to characterize the aerosol produced by different nebulizers through the use of sup(99m)Tc-DTPA normally applied in pulmonar ventilation studies in nuclear medicine. We have found the mass distribution's MMD and the geometric standard deviation for this type of radioaerosol. (author)

  1. Droplet size prediction in ultrasonic nebulization for non-oxide ceramic powder synthesis.

    Science.gov (United States)

    Muñoz, Mariana; Goutier, Simon; Foucaud, Sylvie; Mariaux, Gilles; Poirier, Thierry

    2018-03-01

    Spray pyrolysis process has been used for the synthesis of non-oxide ceramic powders from liquid precursors in the Si/C/N system. Particles with a high thermal stability and with variable composition and size distribution have been obtained. In this process, the mechanisms involved in precursor decomposition and gas phase recombination of species are still unknown. The final aim of this work consists in improving the whole process comprehension by an experimental/modelling approach that helps to connect the synthesized particles characteristics to the precursor properties and process operating parameters. It includes the following steps: aerosol formation by a piezoelectric nebulizer, its transport and the chemical-physical phenomena involved in the reaction processes. This paper focuses on the aerosol characterization to understand the relationship between the liquid precursor properties and the liquid droplet diameter distribution. Liquids with properties close to the precursor of interest (hexamethyldisilazane) have been used. Experiments have been performed using a shadowgraphy technique to determine the drop size distribution of the aerosol. For all operating parameters of the nebulizer device and liquids used, bimodal droplet size distributions have been obtained. Correlations proposed in the literature for the droplet size prediction by ultrasonic nebulization were used and adapted to the specific nebulizer device used in this study, showing rather good agreement with experimental values. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Pneumatic Artificial Muscle Actuation and Modeling

    Science.gov (United States)

    Leephakpreeda, Thananchai; Wickramatunge, Kanchana C.

    2009-10-01

    A Pneumatic Artificial Muscle (PAM) yields a natural muscle-like actuator with a high force to weight ratio, a soft and flexible structure, and adaptable compliance for a humanoid robot, rehabilitation and prosthetic appliances to the disabled, etc. To obtain optimum design and usage, the mechanical behavior of the PAM need to be understood. In this study, observations of experimental results reveal an empirical model for relations of physical variables, contraction and air pressure within the PAM, as compared to mechanical characteristics, such as stiffness or/and pulling forces of the PAM available now in market.

  3. A pneumatic muscle hand therapy device.

    Science.gov (United States)

    Koeneman, E J; Schultz, R S; Wolf, S L; Herring, D E; Koeneman, J B

    2004-01-01

    Intensive repetitive therapy improves function and quality of life for stroke patients. Intense therapies to overcome upper extremity impairment are beneficial, however, they are expensive because, in part, they rely on individualized interaction between the patient and rehabilitation specialist. The development of a pneumatic muscle driven hand therapy device, the Mentortrade mark, reinforces the need for volitional activation of joint movement while concurrently offering knowledge of results about range of motion, muscle activity or resistance to movement. The device is well tolerated and has received favorable comments from stroke survivors, their caregivers, and therapists.

  4. Blood Sample Transportation by Pneumatic Transportation Systems

    DEFF Research Database (Denmark)

    Nybo, Mads; Lund, Merete E; Titlestad, Kjell

    2018-01-01

    BACKGROUND: Pneumatic transportation systems (PTSs) are increasingly used for transportation of blood samples to the core laboratory. Many studies have investigated the impact of these systems on different types of analyses, but to elucidate whether PTSs in general are safe for transportation...... analysis, and the hemolysis index). CONCLUSIONS: Owing to their high degree of heterogeneity, the retrieved studies were unable to supply evidence for the safety of using PTSs for blood sample transportation. In consequence, laboratories need to measure and document the actual acceleration forces...

  5. Repeating pneumatic pellet injector in JAERI

    International Nuclear Information System (INIS)

    Kasai, Satoshi; Hasegawa, Kouichi; Suzuki, Sadaaki; Miura, Yukitoshi; Oda, Yasushi; Onozuka, Masanori; Tsujimura, Seiichi.

    1992-09-01

    A repeating pneumatic pellet injector has been developed and constructed at Japan Atomic Energy Research Institute. This injector can provide repetitive pellet injection to fuel tokamak plasmas for an extended period of time, aiming at the improvement of plasma performance. The pellets with nearly identical speed and mass can be repeatedly injected with a repetition rate of 2-3.3 Hz and a speed of up to 1.7 km/s by controlling the temperature of the cryogenic system, the piston speed and the pressure of the propellant gas. (author)

  6. Particle segregation in pneumatic conveying lines

    Energy Technology Data Exchange (ETDEWEB)

    McGlinchey, D.; Marjanovic, P.; Cook, S.; Jones, M.G. [Glasgow Caledonian University, Glasgow (United Kingdom). Centre for Industrial Bulk Solids Handling

    2000-07-01

    This investigation studied segregation of particles during pneumatic transport from a theoretical and experimental perspective. Dilute phase or suspension flow and dense phase (non-suspension flow) were both considered. A computer model was generated based on the conservation equations to investigate dilute phase conditions; an initial qualitative investigation of material behaviour being conveyed in dense phase was made with plastic pellets and salt as a segregating mixture in a small test rig and the results from a full scale test rig conveying two grades of coal of different size distributions are discussed. 11 refs., 9 figs., 1 tab.

  7. Robust PID Controller for a Pneumatic Actuator

    Directory of Open Access Journals (Sweden)

    Skarpetis Michael G.

    2016-01-01

    Full Text Available In this paper the position control pneumatic actuator using a robust PID controller is presented. The parameters of the PID controller are computed using a Hurwitz invariability technique enriched with a Simulated Annealing Algorithm. The nonlinear model involves uncertain parameters due to linearization of the servo valve, variations of the initial volume of the cylinder and variation of the external load. The problem is proven to be solvable and the controller parameters are chosen to provide a suboptimal solution for tracking error minimization. Simulation results are presented for the nonlinear model.

  8. Repeating pneumatic pellet injector in JAERI

    Energy Technology Data Exchange (ETDEWEB)

    Kasai, Satoshi; Hasegawa, Kouichi; Suzuki, Sadaaki; Miura, Yukitoshi (Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment); Oda, Yasushi; Onozuka, Masanori; Tsujimura, Seiichi.

    1992-09-01

    A repeating pneumatic pellet injector has been developed and constructed at Japan Atomic Energy Research Institute. This injector can provide repetitive pellet injection to fuel tokamak plasmas for an extended period of time, aiming at the improvement of plasma performance. The pellets with nearly identical speed and mass can be repeatedly injected with a repetition rate of 2-3.3 Hz and a speed of up to 1.7 km/s by controlling the temperature of the cryogenic system, the piston speed and the pressure of the propellant gas. (author).

  9. Mathematical Modeling of Diaphragm Pneumatic Motors

    Directory of Open Access Journals (Sweden)

    Fojtášek Kamil

    2014-03-01

    Full Text Available Pneumatic diaphragm motors belong to the group of motors with elastic working parts. This part is usually made of rubber with a textile insert and it is deformed under the pressure of a compressed air or from the external mass load. This is resulting in a final working effect. In this type of motors are in contact two different elastic environments – the compressed air and the esaltic part. These motors are mainly the low-stroke and working with relatively large forces. This paper presents mathematical modeling static properties of diaphragm motors.

  10. Delivery of albuterol and ipratropium bromide from two nebulizer systems in chronic stable asthma. Efficacy and pulmonary deposition

    International Nuclear Information System (INIS)

    Johnson, M.A.; Newman, S.P.; Bloom, R.; Talaee, N.; Clarke, S.W.

    1989-01-01

    Bronchodilator responses to both nebulized albuterol (salbutamol) and ipratropium bromide and aerosol delivery to the tracheobronchial tree have been assessed in eight patients with chronic stable asthma (mean baseline FEV1, 50 percent; reversibility greater than 20 percent). Two commercially available nebulizer systems were used, namely, a Turret nebulizer operated at a compressed gas flow rate of 12 L/min (droplet MMD, 3.3 mu) and an Inspiron nebulizer driven at 6 L/min (MMD, 7.7 mu). Albuterol was given as doses of 250 micrograms, 250 micrograms, 500 micrograms, and 1,000 micrograms (cumulative dose, 2 mg) and ipratropium bromide as doses of 50 micrograms, 50 micrograms, 100 micrograms, and 200 micrograms (cumulative dose, 400 micrograms) at intervals of 35 minutes. For albuterol, bronchodilatation was significantly (p less than 0.05) greater at all dosage levels with the Turret. For ipratropium, bronchodilatation was similar for both nebulizers. Measurements of aerosol deposition using 99m Tc-labelled pentetic acid (diethylenetriamine pentaacetic acid; DTPA) showed that 9.1 +/- 1.1 percent and 2.7 +/- 0.2 percent of the dose reached the lungs during nebulization to dryness for Turret and Inspiron, respectively (p less than 0.01); distribution within the lungs was similar for the two aerosols. Selection of nebulizer apparatus can influence delivery of aerosol and subsequent bronchodilator response to albuterol in patients with chronic stable asthma but is less important for aerosol delivery of ipratropium bromide in these patients

  11. Variable camber wing based on pneumatic artificial muscles

    Science.gov (United States)

    Yin, Weilong; Liu, Libo; Chen, Yijin; Leng, Jinsong

    2009-07-01

    As a novel bionic actuator, pneumatic artificial muscle has high power to weight ratio. In this paper, a variable camber wing with the pneumatic artificial muscle is developed. Firstly, the experimental setup to measure the static output force of pneumatic artificial muscle is designed. The relationship between the static output force and the air pressure is investigated. Experimental result shows the static output force of pneumatic artificial muscle decreases nonlinearly with increasing contraction ratio. Secondly, the finite element model of the variable camber wing is developed. Numerical results show that the tip displacement of the trailing-edge increases linearly with increasing external load and limited with the maximum static output force of pneumatic artificial muscles. Finally, the variable camber wing model is manufactured to validate the variable camber concept. Experimental result shows that the wing camber increases with increasing air pressure and that it compare very well with the FEM result.

  12. Development of the pneumatic service robot with a hybrid type

    International Nuclear Information System (INIS)

    Choi, Cheol U; Choi, Hyeun Seok; Han, Chang Soo

    2001-01-01

    In this paper, the pneumatic service robot with a hybrid type is developed. A pneumatic has the advantage of good compliance, high payload-to-weight and payload-to-volume ratios, high speed and force capabilities. Using pneumatic actuators which have low stiffness, the service robot can guarantee safety. By suggesting a new serial-parallel hybrid type for the service robot which separates into positioning motion and orienting motion, we can achieve large workspace and high strength-to-moving-weight ratio at the same time. A sliding mode controller can be designed for tracking the desired output using the Lyapunov stability theory and structural properties of pneumatic servo systems. Through many experiments of circular trajectory, the pneumatic service robot is evaluated and verified

  13. Fractional-Order Control of Pneumatic Position Servosystems

    Directory of Open Access Journals (Sweden)

    Cao Junyi

    2011-01-01

    Full Text Available A fractional-order control strategy for pneumatic position servosystem is presented in this paper. The idea of the fractional calculus application to control theory was introduced in many works, and its advantages were proved. However, the realization of fractional-order controllers for pneumatic position servosystems has not been investigated. Based on the relationship between the pressure in cylinder and the rate of mass flow into the cylinder, the dynamic model of pneumatic position servo system is established. The fractional-order controller for pneumatic position servo and its implementation in industrial computer is designed. The experiments with fractional-order controller are carried out under various conditions, which include sine position signal with different frequency and amplitude, step position signal, and variety inertial load. The results show the effectiveness of the proposed scheme and verify their fine control performance for pneumatic position servo system.

  14. Simultaneous electrothermal vaporization and nebulizer sample introduction system for inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Arnquist, Isaac J.; Kreschollek, Thomas E.; Holcombe, James A.

    2011-01-01

    The novel analytical application of the combination of an inline electrothermal vaporization (ETV) and nebulization source for inductively coupled plasma mass spectrometry (ICP-MS) has been studied. Wet plasma conditions are sustained during ETV introduction by 200 mL/min gas flow through the nebulizer, which is merged with the ETV transport line at the torch. The use of a wet plasma with ETV introduction avoided the need to change power settings and torch positions that normally accompany a change from wet to dry plasma operating conditions. This inline-ETV source is shown to have good detection limits for a variety of elements in both HNO 3 and HCl matrices. Using the inline-ETV source, improved limits of detection (LOD) were obtained for elements typically suppressed by polyatomic interferences using a nebulizer. Specifically, improved LODs for 51 V and 53 Cr suffering from Cl interferences ( 51 ClO + and 53 ClO + respectively) in a 1% HCl matrix were obtained using the inline-ETV source. LODs were improved by factors of 65 and 22 for 51 V and 53 Cr, respectively, using the inline-ETV source compared to a conventional concentric glass nebulizer. For elements without polyatomic interferences, LODs from the inline-ETV were comparable to conventional dry plasma ETV-ICP time-of-flight mass spectrometry results. Lastly, the inline-ETV source offers a simple means of changing from nebulizer introduction to inline-ETV introduction without extinguishing the plasma. This permits, for example, the use of the time-resolved ETV-ICP-MS signals to distinguish between an analyte ion and polyatomic isobar.

  15. Accurate assessment of adherence: self-report and clinician report vs electronic monitoring of nebulizers.

    Science.gov (United States)

    Daniels, Tracey; Goodacre, Lynne; Sutton, Chris; Pollard, Kim; Conway, Steven; Peckham, Daniel

    2011-08-01

    People with cystic fibrosis have a high treatment burden. While uncertainty remains about individual patient level of adherence to medication, treatment regimens are difficult to tailor, and interventions are difficult to evaluate. Self- and clinician-reported measures are routinely used despite criticism that they overestimate adherence. This study assessed agreement between rates of adherence to prescribed nebulizer treatments when measured by self-report, clinician report, and electronic monitoring suitable for long-term use. Seventy-eight adults with cystic fibrosis were questioned about their adherence to prescribed nebulizer treatments over the previous 3 months. Self-report was compared with clinician report and stored adherence data downloaded from the I-Neb nebulizer system. Adherence measures were expressed as a percentage of the prescribed regimen, bias was estimated by the paired difference in mean (95% CI) patient and clinician reported and actual adherence. Agreement between adherence measures was calculated using intraclass correlation coefficients (95% CI), and disagreements for individuals were displayed using Bland-Altman plots. Patient-identified prescriptions matched the medical record prescription. Median self-reported adherence was 80% (interquartile range, 60%-95%), whereas median adherence measured by nebulizer download was 36% (interquartile range, 5%-84.5%). Nine participants overmedicated and underreported adherence. Median clinician report ranged from 50% to 60%, depending on profession. Extensive discrepancies between self-report and clinician report compared with nebulizer download were identified for individuals. Self- and clinician-reporting of adherence does not provide accurate measurement of adherence when compared with electronic monitoring. Using inaccurate measures has implications for treatment burden, clinician prescribing practices, cost, and accuracy of trial data.

  16. Transforming insect electromyograms into pneumatic muscle control

    Science.gov (United States)

    Rutter, Brandon; Mu, Laiyong; Ritzmann, Roy; Quinn, Roger

    2006-05-01

    Robots can serve as hardware models for testing biological hypotheses. Both for this reason and to improve the state of the art of robotics, we strive to incorporate biological principles of insect locomotion into robotic designs. Previous research has resulted in a line of robots with leg designs based on walking and climbing movements of the cockroach Blaberus discoidalis. The current version, Robot V, uses muscle-like Braided Pneumatic Actuators (BPAs). In this paper, we use recorded electromyograms (EMGs) to drive robot joint motion. A muscle activation model was developed that transforms EMGs recorded from behaving cockroaches into appropriate commands for the robot. The transform is implemented by multiplying the EMG by an input gain thus generating an input pressure signal, which is used to drive a one-way closed loop pressure controller. The actuator then can be modeled as a capacitance with input rectification. The actuator exhaust valve is given a leak rate, making the transform a leaky integrator for air pressure, which drives the output force of the actuator. We find parameters of this transform by minimizing the difference between the robot motion produced and that observed in the cockroach. Although we have not reproduced full-amplitude cockroach motion using this robot, results from evaluation on reduced-amplitude cockroach angle data strongly suggest that braided pneumatic actuators can be used as part of a physical model of a biological system.

  17. Pneumatic load compensating or controlling system

    Science.gov (United States)

    Rogers, J. R. (Inventor)

    1975-01-01

    A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

  18. Flowfield Analysis of a Pneumatic Solenoid Valve

    Directory of Open Access Journals (Sweden)

    Sheam-Chyun Lin

    2018-07-01

    Full Text Available Pneumatic solenoid valve has been widely used in the vehicle control systems for meeting the rapid-reaction demand triggered by the dynamic conditions encountered during the driving course of vehicle. For ensuring the safety of human being, the reliable and effective solenoid valve is in great demand to shorten the reaction time and thus becomes the topic of this research. This numerical study chooses a commercial 3/2-way solenoid valve as the reference valve for analysing its performance. At first, CFD software Fluent is adopted to simulate the flow field associated with the valve configuration. Then, the comprehensive flow visualization is implemented to identify the locations of adverse flow patterns. Accordingly, it is found that a high-pressure region exists in the zone between the nozzle exit and the top of iron core. Thereafter, the nozzle diameter and the distance between nozzle and spool are identified as the important design parameters for improving the pressure response characteristics of valve. In conclusion, this work establishes a rigorous and systematic CFD scheme to evaluate the performance of pneumatic solenoid valve.

  19. Development and implementation of a dustfree and efficient pneumatic harvesting method; Poelyttoemaen ja tehokkaan imukokoamismenetelmaen kehittaeminen ja kaeyttoeoenotto

    Energy Technology Data Exchange (ETDEWEB)

    Nurminen, T; Ruokolainen, O; Rytkoenen, P.; Saastamoinen, V. [Vapo Oy, Jyvaeskylae (Finland); Kallio, M.; Aalto, J.; Leinonen, A.; Mehto, M. [VTT Energy, Jyvaeskylae (Finland)

    1997-12-01

    The overall aim of the research work (1995 - 1998) is to develop dust separators of the pneumatic harvester, to eliminate dust emissions and to plan and implement a more efficient pneumatic harvesting method. New JIK-35/96 pneumatic harvesters equipped with four secondary separating cyclones (17 units) were taken into use in spring 1996. In addition, 15 JIK-35 pneumatic harvesters constructed earlier were modified dustfree. The mechanical strength of the harvesters was improved by after-installations and by changing the drive method during harvesting. JIK-35/96 pneumatic harvester (test unit) was developed further during summertime. The greatest modification was testing of three secondary cyclones with a larger diameter. Dust separation of the larger cyclones was poorer than that of cyclones with a smaller diameter. In test runs, the test unit collected peat about 10 % more than the other harvesters of JIK-35 type. The fuel consumption of the test unit was about a fifth higher than that of the conventional JIK-35 harvester (20 vs 25 l/h). The larger pneumatic harvester, a prototype of 45 m{sup 3}, operated as a whole as expected. Exhaust air from the settling chamber of the harvester, and dust distributed well to the four parallel cyclones. Problems were high power demand and low pressure in the harvesting bin compared to those of JIK-35/96. The peat harvesting efficiency of the prototype was less than 2 kg/s m(m = nozzle of 1 m width), while the corresponding value of JIK-35/96 ranged 2.5 - 4 kg/s m. In continuation, the aim is to eliminate problems of the prototype and to construct a more efficient version, i.e., by enlarging the width

  20. Experience and prospects of using the pneumatic designs in underground mining

    Energy Technology Data Exchange (ETDEWEB)

    Rakhutin, V.S. [National Mining University of Ukraine, Dnipropetrovsk (Ukraine)

    1999-07-01

    The article reviews the experience of application of pneumatic designs ('flexible shells') in coal mines (pneumatic cogs and supports), ore mines (pneumatic cofferdams and partitions in filling), and in the construction of mines and underground constructions (pneumatic casings, temporary (pilot) supports). 2 refs.

  1. The effect of pneumatic dilation in management of postfundoplication dysphagia.

    Science.gov (United States)

    Sunjaya, D; Podboy, A; Blackmon, S H; Katzka, D; Halland, M

    2017-06-01

    Fundoplication surgery is a commonly performed procedure for gastro-esophageal reflux disease or hiatal hernia repair. Up to 10% of patients develop persistent postoperative dysphagia after surgery. Data on the effectiveness of pneumatic dilation for treatment are limited. The aim of this study was to evaluate clinical outcomes and identify clinical factors associated with successful response to pneumatic dilation among patients with persistent postfundoplication dysphagia (PPFD). We retrospectively evaluated patients who had undergone pneumatic dilation for PPFD between 1999 and 2016. Patients with dysphagia or achalasia prior to fundoplication were excluded. Demographic information, surgical history, severity of dysphagia, and clinical outcomes were collected. Data pertaining to esophagram, manometry, endoscopy, and pneumatic dilation were also collected. We identified 38 patients (82% female, 95% Caucasian, and median age 59 years) with PPFD who completed pneumatic dilation. The median postfundoplication dysphagia score was 2. Eleven patients had abnormal peristalsis on manometry. Seventeen patients reported response (seven complete) with an average decrease of 1 in their dysphagia score. Fifteen patients underwent reoperation due to PPFD. Hiatal hernia repair was the only factor that predicts a higher response rate to pneumatic dilation. Only one patient in our study developed complication (pneumoperitoneum) from pneumatic dilation. We found that pneumatic dilation to be a safe treatment option for PPFD with moderate efficacy. Patients who developed PPFD after a hiatal hernia repair may gain the greatest benefit after pneumatic dilation. We were not able to identify additional clinical, radiological, endoscopic, or manometric parameters that were predictive of response. © 2017 John Wiley & Sons Ltd.

  2. Effect of extended infusion of meropenem and nebulized amikacin on Gram-negative multidrug-resistant ventilator-associated pneumonia

    Directory of Open Access Journals (Sweden)

    Mona Ahmed Ammar

    2018-01-01

    Conclusions: Adding nebulized amikacin to systemic antibiotics in patients with VAP caused by Gram-negative MDRO may offer efficacy benefits, and the use of extended infusions of meropenem could improve the clinical outcomes in critically ill populations.

  3. Comparison of the Bronchodilative Effects of Salbutamol Delivered via Three Mesh Nebulizers in Children with Bronchial Asthma

    Directory of Open Access Journals (Sweden)

    Fumitake Kurosaka

    2009-01-01

    Conclusions: Overall, all 3 mesh nebulizers were useful devices in treating bronchial asthma, although some differences in lung function improvement were evident. The limitation of this study is that subjects did not include patients with severe asthma attacks.

  4. Designed pneumatic valve actuators for controlled droplet breakup and generation.

    Science.gov (United States)

    Choi, Jae-Hoon; Lee, Seung-Kon; Lim, Jong-Min; Yang, Seung-Man; Yi, Gi-Ra

    2010-02-21

    The dynamic breakup of emulsion droplets was demonstrated in double-layered microfluidic devices equipped with designed pneumatic actuators. Uniform emulsion droplets, produced by shearing at a T-junction, were broken into smaller droplets when they passed downstream through constrictions formed by a pneumatically actuated valve in the upper control layer. The valve-assisted droplet breakup was significantly affected by the shape and layout of the control valves on the emulsion flow channel. Interestingly, by actuating the pneumatic valve immediately above the T-junction, the sizes of the emulsion droplets were controlled precisely in a programmatic manner that produced arrays of uniform emulsion droplets in various sizes and dynamic patterns.

  5. Hydraulics and pneumatics a technician's and engineer's guide

    CERN Document Server

    Parr, Andrew

    1991-01-01

    Hydraulics and Pneumatics: A Technician's and Engineer's Guide provides an introduction to the components and operation of a hydraulic or pneumatic system. This book discusses the main advantages and disadvantages of pneumatic or hydraulic systems.Organized into eight chapters, this book begins with an overview of industrial prime movers. This text then examines the three different types of positive displacement pump used in hydraulic systems, namely, gear pumps, vane pumps, and piston pumps. Other chapters consider the pressure in a hydraulic system, which can be quickly and easily controlled

  6. Hydraulics and pneumatics a technician's and engineer's guide

    CERN Document Server

    Parr, Andrew

    2011-01-01

    Nearly all industrial processes require objects to be moved, manipulated or subjected to some sort of force. Such movements and manipulations are frequently accomplished by means of devices driven by liquids (hydraulics) or air (pneumatics), the subject of this book. Hydraulics and Pneumatics is written by a practicing process control engineer as a guide to the successful operation of hydraulic and pneumatic systems for all engineers and technicians working with them. Keeping mathematics and theory to a minimum, this practical guide is thorough but accessible to technicians without a

  7. Fueling of magnetically confined plasmas by single- and two-stage repeating pneumatic pellet injectors

    International Nuclear Information System (INIS)

    Gouge, M.J.; Combs, S.K.; Foust, C.R.; Milora, S.L.

    1990-01-01

    Advanced plasma fueling systems for magnetic fusion confinement experiments are under development at Oak Ridge National Laboratory (ORNL). The general approach is that of producing and accelerating frozen hydrogenic pellets to speeds in the kilometer-per-second range using single shot and repetitive pneumatic (light-gas gun) pellet injectors. The millimeter-to-centimeter size pellets enter the plasma and continuously ablate because of the plasma electron heat flux, depositing fuel atoms along the pellet trajectory. This fueling method allows direct fueling in the interior of the hot plasma and is more efficient than the alternative method of injecting room temperature fuel gas at the wall of the plasma vacuum chamber. Single-stage pneumatic injectors based on the light-gas gun concept have provided hydrogenic fuel pellets in the speed range of 1--2 km/s in single-shot injector designs. Repetition rates up to 5 Hz have been demonstrated in repetitive injector designs. Future fusion reactor-scale devices may need higher pellet velocities because of the larger plasma size and higher plasma temperatures. Repetitive two-stage pneumatic injectors are under development at ORNL to provide long-pulse plasma fueling in the 3--5 km/s speed range. Recently, a repeating, two-stage light-gas gun achieved repetitive operation at 1 Hz with speeds in the range of 2--3 km/s

  8. Position Control of Pneumatic Actuator Using Self-Regulation Nonlinear PID

    Directory of Open Access Journals (Sweden)

    Syed Najib Syed Salim

    2014-01-01

    Full Text Available The enhancement of nonlinear PID (N-PID controller for a pneumatic positioning system is proposed to improve the performance of this controller. This is executed by utilizing the characteristic of rate variation of the nonlinear gain that is readily available in N-PID controller. The proposed equation, namely, self-regulation nonlinear function (SNF, is used to reprocess the error signal with the purpose of generating the value of the rate variation, continuously. With the addition of this function, a new self-regulation nonlinear PID (SN-PID controller is proposed. The proposed controller is then implemented to a variably loaded pneumatic actuator. Simulation and experimental tests are conducted with different inputs, namely, step, multistep, and random waveforms, to evaluate the performance of the proposed technique. The results obtained have been proven as a novel initiative at examining and identifying the characteristic based on a new proposal controller resulting from N-PID controller. The transient response is improved by a factor of 2.2 times greater than previous N-PID technique. Moreover, the performance of pneumatic positioning system is remarkably good under various loads.

  9. An instrumented object for hand exercise and assessment using a pneumatic pressure sensor

    Science.gov (United States)

    Mohan, A.; Tharion, G.; Kumar, R. K.; Devasahayam, S. R.

    2018-05-01

    Measurement of grip force is important for both exercise training and assessment of the hand during physical rehabilitation. The standard method uses a grip dynamometer which measures the force between the fingers and opposing thumb. The primary limitation of the grip dynamometer is the restriction of measurement to cylindrical grasps. Any deformation of the hand due to muscular or skeletal disease makes the grip dynamometer difficult or impossible to use. An alternative to the grip dynamometer is a sealed pneumatic object that can be gripped by the hand. Measurement of the internal pressure in the object can be related to the grip force. In this paper, we analyze such a pneumatic pressure sensing object for hand grip assessment and also describe an easy fabrication of the grip sensor. The instrumented object presented in this paper is designed to assess both the maximal voluntary grip forces and continuous grip force to monitor control of hand function during exercise under instruction from a therapist. Potential uses of such a pneumatic pressure sensing object for hand grip are in physical rehabilitation of patients following paralysing illnesses like stroke and spinal cord injury.

  10. Static and dynamic stability of pneumatic vibration isolators and systems of isolators

    Science.gov (United States)

    Ryaboy, Vyacheslav M.

    2014-01-01

    Pneumatic vibration isolation is the most widespread effective method for creating vibration-free environments that are vital for precise experiments and manufacturing operations in optoelectronics, life sciences, microelectronics, nanotechnology and other areas. The modeling and design principles of a dual-chamber pneumatic vibration isolator, basically established a few decades ago, continue to attract attention of researchers. On the other hand, behavior of systems of such isolators was never explained in the literature in sufficient detail. This paper covers a range of questions essential for understanding the mechanics of pneumatic isolation systems from both design and application perspectives. The theory and a model of a single standalone isolator are presented in concise form necessary for subsequent analysis. Then the dynamics of a system of isolators supporting a payload is considered with main attention directed to two aspects of their behavior: first, the static stability of payloads with high positions of the center of gravity; second, dynamic stability of the feedback system formed by mechanical leveling valves. The direct method of calculating the maximum stable position of the center of gravity is presented and illustrated by three-dimensional stability domains; analytic formulas are given that delineate these domains. A numerical method for feedback stability analysis of self-leveling valve systems is given, and the results are compared with the analytical estimates for a single isolator. The relation between the static and dynamic phenomena is discussed.

  11. A durability study of a paracorporeal pulsatile electro-mechanical pneumatic biventricular assist device.

    Science.gov (United States)

    Choi, Hyuk; Lee, Heung-Man; Nam, Kyoung Won; Choi, Jaesoon; Lee, Jung-Joo; Kim, Ho Chul; Song, Seung Joon; Ahn, Chi Bum; Son, Ho Sung; Lim, Choon Hak; Son, Kuk Hui; Park, Yong Doo; Jeong, Gi Seok; Sun, Kyung

    2011-06-01

    In 2002, the paracorporeal pulsatile electro-mechanical pneumatic ventricular assist device (VAD) began to be developed by the Korea Artificial Organ Center at Korea University under a Health & Medical Technology Research and Development program which finished in 2008. In vitro durability testing was conducted on the paracorporeal pulsatile pneumatic VAD to determine device durability and to evaluate device failures. The 1- and 2-year reliability of the paracorporeal pulsatile pneumatic VAD was shown to be 91.2% and 54.9%, respectively, with an 80% confidence level. Failure modes were analyzed using fault tree analysis, with customized software continuously acquiring data during the test period. After this period, 21 in vivo animal tests were done, with 14 cases of left atrium to left ventricle (LV) inflow cannulation (36Fr)/outflow grafting to descending aorta, and seven cases of apex cannulation of LV to descending aorta (12 mm). The longest postoperative day (182 days) in Korea was recently recorded in in vivo animal testing (bovine, 90 kg, male, 3.5-4.0 L/min flow rate, and 55 bpm). © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Revisiting the Closed-Loop Pneumatic Drive Design

    Directory of Open Access Journals (Sweden)

    K D. Efremova

    2017-01-01

    Full Text Available Compressibility of air used as a working medium in pneumatic control systems raise certain difficulties in calculating dynamic characteristics of the pneumatic drive and solving problems of its regulation. These difficulties are due to a number of factors:   - flow of compressed air through the narrow working splits of distributive and throttling devices of pneumatic control;   - filling in and discharging the pneumatic actuator cavities of variable volume (piston and rod cavities of the air-cylinder under conditions of heat and mass transfer;   - simultaneous filling in and discharging a pneumatic cavity of permanent volume (receiver;   - pneumatic cylinder piston end positioning alteration under variable loading and at the moment of shutdown;A number of factors have a significant impact on the piston end positioning alteration value, namely an initial positioning of the piston at the moment of its shutdown, which determines the volume of the pneumatic cylinder cavity; a value of the permanent component of the load at the moment the piston shuts down and its change during keeping time period; transmission coefficient of the positioning component of the load; a working area of the air-cylinder piston and also an atmospheric pressure reduction, which can significantly affect the operation of control systems of a small aircraft at high altitudes.With a view to deepening the problem of calculation and design of pneumatic actuators, it is shown that the relationship between the parameters of compressed air and their changes is determined by the properties of thermodynamic processes under conditions of heat and mass transfer. In pneumatic actuators for general industrial use, the pressure of compressed air does not exceed a value equal to 1 MPa. In this case, the working medium can be regarded as an ideal gas in simplified calculations.Based on the general equation of thermodynamics, the paper considers the particular cases of a changing gas

  13. Control performance of pneumatic artificial muscle

    Science.gov (United States)

    Saga, Norihiko; Chonan, Seiji

    2007-01-01

    The robot in the future will be lightened and, in addition, the complex tasks will be done by the consumption of less energy. To achieve this, the development of an artificial muscle actuator which is as soft as a human-being becomes indispensable. At present, the artificial muscle actuator used is the McKibben type, but the heat and mechanical loss of this actuator are large because of the friction caused by the expansion and contraction of the sleeve. Therefore, we developed the artificial muscle tube where the Carbon fiber of the high intensity had been built into the silicon tube. In this report, the results of the examined the mechanical property of silicone rubber is reported, and the shrinking characteristics, response characteristics, and control performance as a pneumatic actuator are reported.

  14. A fluidic/pneumatic interface amplifier

    Science.gov (United States)

    Limbert, D. E.; Kegel, T. M.

    The development of a low cost, reliable, linear pressure amplifier to interface Laminar Proportional Amplifiers (LPA) to pneumatic controllers is presented. The amplifier consists of an LPA input stage and an output stage consisting of a venturi in series with a bellows nozzle valve. The LPA output drives the bellows nozzle valve thereby altering the flowrate through the venturi. The pressure within the venturi throat region, which is the amplifier output, changes with the flowrate. Non-linear characteristics, due to supersonic flow within the venturi, are altered through the use of feedback to the LPA input. A computer based model, to aid in optimizing the amplifier design, is developed. This model incorporates the effects of shock waves and boundary layers within the venturi. Good correspondence between the model and an experimental prototype is shown.

  15. Inductance position sensor for pneumatic cylinder

    Directory of Open Access Journals (Sweden)

    Pavel Ripka

    2018-04-01

    Full Text Available The position of the piston in pneumatic cylinder with aluminum wall can be measured by external inductance sensor without modifications of the aluminum piston and massive iron piston rod. For frequencies below 20 Hz the inductance is increasing with inserting rod due to the rod permeability. This mode has disadvantage of slow response to piston movement and also high temperature sensitivity. At the frequency of 45 Hz the inductance is position independent, as the permeability effect is compensated by the eddy current effect. At higher frequencies eddy current effects in the rod prevail, the inductance is decreasing with inserting rod. In this mode the sensitivity is smaller but the sensor response is fast and temperature stability is better. We show that FEM simulation of this sensor using measured material properties gives accurate results, which is important for the sensor optimization such as designing the winding geometry for the best linearity.

  16. Inductance position sensor for pneumatic cylinder

    Science.gov (United States)

    Ripka, Pavel; Chirtsov, Andrey; Mirzaei, Mehran; Vyhnanek, Jan

    2018-04-01

    The position of the piston in pneumatic cylinder with aluminum wall can be measured by external inductance sensor without modifications of the aluminum piston and massive iron piston rod. For frequencies below 20 Hz the inductance is increasing with inserting rod due to the rod permeability. This mode has disadvantage of slow response to piston movement and also high temperature sensitivity. At the frequency of 45 Hz the inductance is position independent, as the permeability effect is compensated by the eddy current effect. At higher frequencies eddy current effects in the rod prevail, the inductance is decreasing with inserting rod. In this mode the sensitivity is smaller but the sensor response is fast and temperature stability is better. We show that FEM simulation of this sensor using measured material properties gives accurate results, which is important for the sensor optimization such as designing the winding geometry for the best linearity.

  17. Pneumatic transport systems for TRIGA reactors

    International Nuclear Information System (INIS)

    Bolton, John A.

    1970-01-01

    Main parameters and advantages of pneumatically operated systems, primarily those operated by gas pressure are discussed. The special irradiation ends for the TRIGA reactor are described. To give some idea of the complexity of some modern systems, the author presents the large system currently operating at the National Bureau of Standards in Washington. In this system, 13 stations are located throughout the radiochemistry laboratories and three irradiation ends are located in the reactor, which is a 14-megawatt unit. The system incorporates practically every fail-safe device possible, including ball valves located on all capsule lines entering the reactor area, designed to close automatically in the event of a reactor scram, and at that time capsules within the reactor would be diverted by means of switches located on the inside of the reactor wall. The whole system is under final control of a permission control panel located in the reactor control room. Many other safety accessories of the system are described

  18. Combined discrete nebulization and microextraction process for molybdenum determination by flame atomic absorption spectrometry (FAAS)

    International Nuclear Information System (INIS)

    Oviedo, Jenny A.; Jesus, Amanda M.D. de; Fialho, Lucimar L.; Pereira-Filho, Edenir R.

    2014-01-01

    Simple and sensitive procedures for the extraction/preconcentration of molybdenum based on vortex-assisted solidified floating organic drop microextraction (VA-SFODME) and cloud point combined with flame absorption atomic spectrometry (FAAS) and discrete nebulization were developed. The influence of the discrete nebulization on the sensitivity of the molybdenum preconcentration processes was studied. An injection volume of 200 μ resulted in a lower relative standard deviation with both preconcentration procedures. Enrichment factors of 31 and 67 and limits of detection of 25 and 5 μ L -1 were obtained for cloud point and VA-SFODME, respectively. The developed procedures were applied to the determination of Mo in mineral water and multivitamin samples. (author)

  19. Production of amorphous nanoparticles by supersonic spray-drying with a microfluidic nebulator

    Science.gov (United States)

    Amstad, Esther; Gopinadhan, Manesh; Holtze, Christian; Osuji, Chinedum O.; Brenner, Michael P.; Spaepen, Frans; Weitz, David A.

    2015-08-01

    Amorphous nanoparticles (a-NPs) have physicochemical properties distinctly different from those of the corresponding bulk crystals; for example, their solubility is much higher. However, many materials have a high propensity to crystallize and are difficult to formulate in an amorphous structure without stabilizers. We fabricated a microfluidic nebulator that can produce amorphous NPs from a wide range of materials, even including pure table salt (NaCl). By using supersonic air flow, the nebulator produces drops that are so small that they dry before crystal nuclei can form. The small size of the resulting spray-dried a-NPs limits the probability of crystal nucleation in any given particle during storage. The kinetic stability of the a-NPs—on the order of months—is advantageous for hydrophobic drug molecules.

  20. Nebulization of the acidified sodium nitrite formulation attenuates acute hypoxic pulmonary vasoconstriction

    Directory of Open Access Journals (Sweden)

    Surber Mark W

    2010-06-01

    Full Text Available Abstract Background Generalized hypoxic pulmonary vasoconstriction (HPV occurring during exposure to hypoxia is a detrimental process resulting in an increase in lung vascular resistance. Nebulization of sodium nitrite has been shown to inhibit HPV. The aim of this project was to investigate and compare the effects of nebulization of nitrite and different formulations of acidified sodium nitrite on acute HPV. Methods Ex vivo isolated rabbit lungs perfused with erythrocytes in Krebs-Henseleit buffer (adjusted to 10% hematocrit and in vivo anesthetized catheterized rabbits were challenged with periods of hypoxic ventilation alternating with periods of normoxic ventilation. After baseline hypoxic challenges, vehicle, sodium nitrite or acidified sodium nitrite was delivered via nebulization. In the ex vivo model, pulmonary arterial pressure and nitric oxide concentrations in exhaled gas were monitored. Nitrite and nitrite/nitrate were measured in samples of perfusion buffer. Pulmonary arterial pressure, systemic arterial pressure, cardiac output and blood gases were monitored in the in vivo model. Results In the ex vivo model, nitrite nebulization attenuated HPV and increased nitric oxide concentrations in exhaled gas and nitrite concentrations in the perfusate. The acidified forms of sodium nitrite induced higher levels of nitric oxide in exhaled gas and had longer vasodilating effects compared to nitrite alone. All nitrite formulations increased concentrations of circulating nitrite to the same degree. In the in vivo model, inhaled nitrite inhibited HPV, while pulmonary arterial pressure, cardiac output and blood gases were not affected. All nitrite formulations had similar potency to inhibit HPV. The tested concentration of appeared tolerable. Conclusion Nitrite alone and in acidified forms effectively and similarly attenuates HPV. However, acidified nitrite formulations induce a more pronounced increase in nitric oxide exhalation.

  1. Nebulizer calibration using lithium chloride: an accurate, reproducible and user-friendly method.

    Science.gov (United States)

    Ward, R J; Reid, D W; Leonard, R F; Johns, D P; Walters, E H

    1998-04-01

    Conventional gravimetric (weight loss) calibration of jet nebulizers overestimates their aerosol output by up to 80% due to unaccounted evaporative loss. We examined two methods of measuring true aerosol output from jet nebulizers. A new adaptation of a widely available clinical assay for lithium (determined by flame photometry, LiCl method) was compared to an existing electrochemical method based on fluoride detection (NaF method). The agreement between the two methods and the repeatability of each method were examined. Ten Mefar jet nebulizers were studied using a Mefar MK3 inhalation dosimeter. There was no significant difference between the two methods (p=0.76) with mean aerosol output of the 10 nebulizers being 7.40 mg x s(-1) (SD 1.06; range 5.86-9.36 mg x s(-1)) for the NaF method and 7.27 mg x s(-1) (SD 0.82; range 5.52-8.26 mg x s(-1)) for the LiCl method. The LiCl method had a coefficient of repeatability of 13 mg x s(-1) compared with 3.7 mg x s(-1) for the NaF method. The LiCl method accurately measured true aerosol output and was considerably easier to use. It was also more repeatable, and hence more precise, than the NaF method. Because the LiCl method uses an assay that is routinely available from hospital biochemistry laboratories, it is easy to use and, thus, can readily be adopted by busy respiratory function departments.

  2. Ultrasonic nebulization extraction/low pressure photoionization mass spectrometry for direct analysis of chemicals in matrices.

    Science.gov (United States)

    Liu, Chengyuan; Zhu, Yanan; Zhou, Zhongyue; Yang, Jiuzhong; Qi, Fei; Pan, Yang

    2015-09-03

    A novel ultrasonic nebulization extraction/low-pressure photoionization (UNE-LPPI) system has been designed and employed for the rapid mass spectrometric analysis of chemicals in matrices. An ultrasonic nebulizer was used to extract the chemicals in solid sample and nebulize the solvent in the nebulization cell. Aerosols formed by ultrasonic were evaporated by passing through a transferring tube, and desolvated chemicals were ionized by the emitted light (10.6 eV) from a Krypton discharge lamp at low pressure (∼68 Pa). First, a series of semi/non-volatile compounds with different polarities, such as polycyclic aromatic hydrocarbons (PAHs), amino acids, dipeptides, drugs, nucleic acids, alkaloids, and steroids were used to test the system. Then, the quantification capability of UNE-LPPI was checked with: 1) pure chemicals, such as 9,10-phenanthrenequinone and 1,4-naphthoquinone dissolved in solvent; 2) soil powder spiked with different amounts of phenanthrene and pyrene. For pure chemicals, the correlation coefficient (R(2)) for the standard curve of 9,10-phenanthrenequinone in the range of 3 ng-20 μg mL(-1) was 0.9922, and the measured limits of detection (LOD) was 1 ng ml(-1). In the case of soil powder, linear relationships for phenanthrene and pyrene from 10 to 400 ng mg(-1) were obtained with correlation coefficients of 0.9889 and 0.9893, respectively. At last, the feasibility of UNE-LPPI for the detection of chemicals in real matrices such as tablets and biological tissues (tea, Citrus aurantium peel and sage (Salvia officinalis) leaf) were successfully demonstrated. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Physics-Based Pneumatic Hammer Instability Model, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this project is to develop a physics-based pneumatic hammer instability model that accurately predicts the stability of hydrostatic bearings...

  4. The Photo-Pneumatic CO2 Analyzer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We are proposing to build a new technology, the photo-pneumatic analyzer. It is small, solid-state, inexpensive, and appropriate for observations of atmospheric...

  5. Design and experiment of pneumatic EPB test platform

    Directory of Open Access Journals (Sweden)

    Jianshi GONG

    2017-02-01

    Full Text Available In order to verify the accuracy and reliability of the function and control strategy of the pneumatic electronic parking brake(EPB system, a test platform of the pneumatic EPB system is designed. The working principle of the air pressure type EPB test platform is introduced, the composition of the platform is confirmed, including air press storage module, braking module, man-machine interaction module, signal imitation module, data collection module, and fault diagnosis module, and the function of rapid charging and discharging of the pneumatic EPB system is carried out. The results show that, compared with manual control valve, the air pressure EPB braking process is more sensitive, and the test platform can meet the test requirements of the pneumatic electronic brake system.

  6. Spot-Welding Gun With Adjustable Pneumatic Spring

    Science.gov (United States)

    Burley, Richard K.

    1990-01-01

    Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

  7. Analytical Solution to the Pneumatic Transient Rod System at ACRR

    International Nuclear Information System (INIS)

    Fehr, Brandon Michael

    2016-01-01

    The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validated against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.

  8. Analytical Solution to the Pneumatic Transient Rod System at ACRR

    Energy Technology Data Exchange (ETDEWEB)

    Fehr, Brandon Michael [Georgia Inst. of Technology, Atlanta, GA (United States)

    2016-01-08

    The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validated against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.

  9. Intelligent Switching Control of Pneumatic Artificial Muscle Manipulator

    Science.gov (United States)

    Ahn, Kyoung Kwan; Thanh, Tu Diep Cong; Ahn, Young Kong

    Problems with the control, oscillatory motion and compliance of pneumatic systems have prevented their widespread use in advanced robotics. However, their compactness, power/weight ratio, ease of maintenance and inherent safety are the factors that could potentially be exploited in sophisticated dexterous manipulator designs. These advantages have led to the development of novel actuators such as the McKibben Muscle, Rubber Actuator and Pneumatic Artificial Muscle Manipulators. However, some limitations still exist, such as deterioration of the performance of transient response due to the change of the external inertia load in the pneumatic artificial muscle manipulator. To overcome this problem, switching algorithm of control parameter using learning vector quantization neural network (LVQNN) is newly proposed, which estimates the external inertia load of the pneumatic artificial muscle manipulator. The effectiveness of the proposed control algorithm is demonstrated through experiments with different external inertia loads.

  10. Orange Houses and Tape Babies Temporary and Nebulous Art in Urban Spaces

    Directory of Open Access Journals (Sweden)

    Carmen L. McClish

    2010-12-01

    Full Text Available This essay argues that the disruption of the routine ways we engage with our cities is necessary for democratic activity and public participation. Building on research that examines the relationship between public spaces and democratic action, I explore temporary forms of creative street installation as interrupting the market-ing pleas that have become the only authorized forms of visual art in our cities. I argue that tactics in urban spaces that are temporary and provide nebulous mean-ings are necessary to grab our attention and make us linger. I propose that these forms of engagement act in the same way as people performing or playing in pub-lic spaces. I specifically employ Yi-Fu Tuan’s theoretical notions of space and movement and Margaret Kohn’s discussion of the significance of presence in pub-lic spaces to examine the creative ways we engage with and experience our cities. I examine two activist/artist projects: Mark Jenkins’ tape installations and Detroit Demolition. My analysis of these two sites demonstrates the importance of citi-zens engaging in their urban spaces. By creating temporary artwork that is nebul-ous in meaning, activists/artists are interrupting the routine ways we experience our cities.

  11. Compatibility and osmolality of inhaled N-acetylcysteine nebulizing solution with fenoterol and ipratropium.

    Science.gov (United States)

    Lee, Tzung-Yi; Chen, Chi-Ming; Lee, Chun-Nin; Chiang, Yi-Chun; Chen, Hsiang-Yin

    2005-04-15

    The compatibility, pH, and osmolality of N-acetylcysteine (NAC) nebulizing solution in the presence of ipratropium bromide or fenoterol hydrobromide were studied. Portions (400 microL) of each mixture were sampled immediately upon mixing and one, two, three, four, five, six, and seven hours after mixing and assayed by high-performance liquid chromatography. Osmolality was measured by sampling 100 microL from the filling cup at a five-minute interval during nebulization and by the freezing-point-depression method. Adding NAC solution to fenoterol solution raised the pH from 3.20 to 7.90 and the osmolality to a mean +/- S.D. of 1400.67 +/- 4.51 mOsm/kg. Fenoterol concentrations decreased to 93.71% and NAC concentrations to 92.54% of initial concentrations after seven hours. Mixing ipratropium with NAC solution raised the pH from 3.74 to 7.95 and the osmolality to a mean +/- S.D. of 1413 +/- 11.79 mOsm/kg. The initial ipratropium concentration declined 7.39% and 10.91% one and two hours after mixing with NAC solution, respectively. NAC and ipratropium were stable in nebulizing solution within one hour of mixing. NAC and fenoterol were compatible for at least seven hours.

  12. Epinephrine Improves the Efficacy of Nebulized Hypertonic Saline in Moderate Bronchiolitis: A Randomised Clinical Trial.

    Directory of Open Access Journals (Sweden)

    J Carlos Flores-González

    Full Text Available There is no evidence that the epinephrine-3% hypertonic saline combination is more effective than 3% hypertonic saline alone for treating infants hospitalized with acute bronchiolitis. We evaluated the efficacy of nebulized epinephrine in 3% hypertonic saline.We performed a randomized, double-blind, placebo-controlled clinical trial in 208 infants hospitalized with acute moderate bronchiolitis. Infants were randomly assigned to receive nebulized 3% hypertonic saline with either 3 mL of epinephrine or 3 mL of placebo, administered every four hours. The primary outcome measure was the length of hospital stay.A total of 185 infants were analyzed: 94 in the epinephrine plus 3% hypertonic saline group and 91 in the placebo plus 3% hypertonic saline group. Baseline demographic and clinical characteristics were similar in both groups. Length of hospital stay was significantly reduced in the epinephrine group as compared with the placebo group (3.94 ±1.88 days vs. 4.82 ±2.30 days, P = 0.011. Disease severity also decreased significantly earlier in the epinephrine group (P = 0.029 and P = 0.036 on days 3 and 5, respectively.In our setting, nebulized epinephrine in 3% hypertonic saline significantly shortens hospital stay in hospitalized infants with acute moderate bronchiolitis compared to 3% hypertonic saline alone, and improves the clinical scores of severity from the third day of treatment, but not before.EudraCT 2009-016042-57.

  13. Heated air humidification versus cold air nebulization in newly tracheostomized patients.

    Science.gov (United States)

    Birk, Richard; Händel, Alexander; Wenzel, Angela; Kramer, Benedikt; Aderhold, Christoph; Hörmann, Karl; Stuck, Boris A; Sommer, J Ulrich

    2017-12-01

    After tracheostomy, the airway lacks an essential mechanism for warming and humidifying the inspired air with the consequent functional impairment and discomfort. The purpose of this study was to compare airway hydration with cold-air nebulization versus heated high-flow humidification on medical interventions and tracheal ciliary beat frequency (CBF). Newly tracheostomized patients (n = 20) were treated either with cold-air nebulization or heated humidification. The number of required tracheal suctioning procedures to clean the trachea and tracheal CBF were assessed. The number of required suctions per day was significantly lower in the heated humidification group with medians 3 versus 5 times per day. Mean CBF was significantly higher in the heated humidification group (6.36 ± 1.49 Hz) compared to the cold-air nebulization group (3.99 ± 1.39 Hz). The data suggest that heated humidification enhanced mucociliary transport leading to a reduced number of required suctioning procedures in the trachea, which may improve postoperative patient care. © 2017 The Authors Head & Neck Published by Wiley Periodicals, Inc.

  14. Second Order Sliding Mode Controller Design for Pneumatic Artificial Muscle

    OpenAIRE

    Ammar Al-Jodah; Laith Khames

    2018-01-01

    In this paper, first and second order sliding mode controllers are designed for a single link robotic arm actuated by two Pneumatic Artificial Muscles (PAMs). A new mathematical model for the arm has been developed based on the model of large scale pneumatic muscle actuator model. Uncertainty in parameters has been presented and tested for the two controllers. The simulation results of the second-order sliding mode controller proves to have a low tracking error and chattering effect as compar...

  15. Electric-Pneumatic Actuator: A New Muscle for Locomotion

    OpenAIRE

    Ahmad Sharbafi, Maziar; Shin, Hirofumi; Zhao, Guoping; Hosoda, Koh; Seyfarth, Andre

    2017-01-01

    A better understanding of how actuator design supports locomotor function may help develop novel and more functional powered assistive devices or robotic legged systems. Legged robots comprise passive parts (e.g., segments, joints and connections) which are moved in a coordinated manner by actuators. In this study, we propose a novel concept of a hybrid electric-pneumatic actuator (EPA) as an enhanced variable impedance actuator (VIA). EPA is consisted of a pneumatic artificial muscle (PAM) a...

  16. Design and experiment of pneumatic EPB test platform

    OpenAIRE

    Jianshi GONG; Tianle JIA; Dali TIAN; Hongliang WANG; Di HUANG

    2017-01-01

    In order to verify the accuracy and reliability of the function and control strategy of the pneumatic electronic parking brake(EPB) system, a test platform of the pneumatic EPB system is designed. The working principle of the air pressure type EPB test platform is introduced, the composition of the platform is confirmed, including air press storage module, braking module, man-machine interaction module, signal imitation module, data collection module, and fault diagnosis module, and the funct...

  17. Safe-geometry pneumatic nuclear fuel powder blender

    International Nuclear Information System (INIS)

    Lyon, W.L.

    1980-01-01

    A safe geometry nuclear fuel powder is claimed blender of a pneumatic type having a plurality of narrow flat-walled blending chambers or ''slab tanks'' extending radially outward from a pneumatic spouting tube having an inlet and an outlet at bottom and top, respectively, open to each slab tank or blending chamber and contained within a cylindrical cone-bottomed shell filled with neutron-absorbing material between the blending chambers

  18. Design and Experiment of 1LFQ-325 Pneumatic Reversible Plough

    OpenAIRE

    Zheng, Xuan; Chen, Xuefeng; Qin, Chaomin; Jia, Libo

    2013-01-01

    A pneumatic reversible plough is developed, which complements to the tractor of 25.7-36.8 kW. The plough adopts the cylinder as reversing mechanism between the right and left plough bodies, and the cylinder can substitute the mechanical reversing mechanism. The pneumatic turnover allows the plough to be operated easily and turned over flexibly. Field experiment results show that indicators of plough performance meet the requirements of the relevant national standards.

  19. Development of pneumatic actuator with low-wave reflection characteristics

    Science.gov (United States)

    Chang, H.; Tsung, T. T.; Jwo, C. S.; Chiang, J. C.

    2010-08-01

    This study aims at the development of a less reflective electromagnetic pneumatic actuator often used in the anechoic chamber. Because a pneumatic actuator on the market is not appropriate for use in such a chamber and a metallic one has high dielectric constant which generates reflective electromagnetic waves to influence test parameters in the chamber. The newly developed pneumatic actuator is made from low dielectric constant plastics with less reflective of electromagnetic. A turbine-type air motor is used to develop the pneumatic actuator and a employ Prony tester is used to run the brake horsepower test for the performance test of pneumatic actuator. Test results indicate that the pneumatic actuator in the minimal starting flow is 17 l/min, and it generates a brake horsepower of 48 mW; in the maximum flow is 26 l/min, it generates a brake horsepower of 108 mW. Therefore, it works with a torque between 0.24 N-m and 0.55 N-m, and such a torque will be sufficient to drive the target button.

  20. Treatments for pediatric achalasia: Heller myotomy or pneumatic dilatation?

    Science.gov (United States)

    Jung, C; Michaud, L; Mougenot, J-F; Lamblin, M-D; Philippe-Chomette, P; Cargill, G; Bonnevalle, M; Boige, N; Bellaïche, M; Viala, J; Hugot, J-P; Gottrand, F; Cezard, J-P

    2010-03-01

    The treatment of achalasia consists of reducing distal esophageal obstruction by either Heller myotomy surgery or endoscopic pneumatic dilatation. The aim of the present study was to evaluate the short- and middle-term results of these procedures in children. For technical reasons, children under six years old (n=8) were treated by surgery only, whereas patients over six years old (n=14) were treated by either Heller myotomy or pneumatic dilatation. Of the children aged under six years, 75% were symptom-free at six months and 83% at 24 months of follow-up. Of the patients aged over six years, complete remission was achieved by Heller myotomy in 44.5% vs. 55.5% by pneumatic dilatation after six months, and in 40% vs. 65%, respectively, after 24 months. Both pneumatic dilatation and Heller myotomy showed significant rates of failure. These results suggest that pneumatic dilatation may be considered a primary treatment in children over six years old. Also, where necessary, Heller myotomy and pneumatic dilatation may be used as complementary treatments.

  1. Method of sections in analytical calculations of pneumatic tires

    Science.gov (United States)

    Tarasov, V. N.; Boyarkina, I. V.

    2018-01-01

    Analytical calculations in the pneumatic tire theory are more preferable in comparison with experimental methods. The method of section of a pneumatic tire shell allows to obtain equations of intensities of internal forces in carcass elements and bead rings. Analytical dependencies of intensity of distributed forces have been obtained in tire equator points, on side walls (poles) and pneumatic tire bead rings. Along with planes in the capacity of secant surfaces cylindrical surfaces are used for the first time together with secant planes. The tire capacity equation has been obtained using the method of section, by means of which a contact body is cut off from the tire carcass along the contact perimeter by the surface which is normal to the bearing surface. It has been established that the Laplace equation for the solution of tasks of this class of pneumatic tires contains two unknown values that requires the generation of additional equations. The developed computational schemes of pneumatic tire sections and new equations allow to accelerate the pneumatic tire structure improvement process during engineering.

  2. [Morphine self-administration by rats using a pneumatic syringe].

    Science.gov (United States)

    Akiyama, Y; Takayama, S

    1988-06-01

    An apparatus for drug self-administration by rats using a pneumatic syringe was developed by Weeks. A microliter syringe operated by a pneumatic cylinder supplies an accurate volume of drug solution within one second. When coefficient of variation of infusion volume was compared among pneumatic syringe, infusion pump, and peristaltic pump, pneumatic syringe showed higher accuracy in infusion volume than the other two pumps. Since the infusion speed by a pneumatic syringe is very rapid (less than one second per infusion), the effect of infusion speed on reinforcing property of morphine was investigated. When rats self-administered 0.1, 0.3, 1.0, and 3.0 mg/kg/infusion of morphine by pneumatic syringes, the patterns of self-infusion were more stable, the number of self-infusions and the amount self-administered were larger, and a dose-response relationship was clearer in comparison with those self-infused the same doses of morphine for 5.6 seconds by infusion pumps or peristaltic pumps.

  3. Key issues in theoretical and functional pneumatic design

    Science.gov (United States)

    Xu, Z. G.; Yang, D. Y.; Liu, W. M.; Liu, T. T.

    2017-10-01

    This paper studies the energy release of the pneumatic engine in different thermodynamic processes, the isothermal process is the highest power output process, while adiabatic process is the lowest energy output process, and the energy release of the pneumatic engine is a multi-state thermodynamic process between them. Therefore heat exchanging should be increased between the pneumatic engine and the outer space, the gas expansion process in the cylinder should be as close as possible to the isothermal process. Heat exchange should be increased between the cylinder and the external spaces. Secondly, the fin structure is studied to increase the heat exchanging between the cylinder body and the outside space. The upper part has fin structures and the lower cylinder has no fin structure, this structure improved the working efficiency of pneumatic engine. Finally the cam and the hydraulic bottle of pneumatic engines are designed. Simulation and theoretical calculation are used to the analysis of the whole structure, which lay the foundation for the manufacturing and design of the pneumatic engines.

  4. A high resolution pneumatic stepping actuator for harsh reactor environments

    Science.gov (United States)

    Tippetts, Thomas B.; Evans, Paul S.; Riffle, George K.

    1993-01-01

    A reactivity control actuator for a high-power density nuclear propulsion reactor must be installed in close proximity to the reactor core. The energy input from radiation to the actuator structure could exceed hundreds of W/cc unless low-cross section, low-absorptivity materials are chosen. Also, for post-test handling and subsequent storage, materials should not be used that are activated into long half-life isotopes. Pneumatic actuators can be constructed from various reactor-compatible materials, but conventional pneumatic piston actuators generally lack the stiffness required for high resolution reactivity control unless electrical position sensors and compensated electronic control systems are used. To overcome these limitations, a pneumatic actuator is under development that positions an output shaft in response to a series of pneumatic pulses, comprising a pneumatic analog of an electrical stepping motor. The pneumatic pulses are generated remotely, beyond the strong radiation environment, and transmitted to the actuator through tubing. The mechanically simple actuator uses a nutating gear harmonic drive to convert motion of small pistons directly to high-resolution angular motion of the output shaft. The digital nature of this actuator is suitable for various reactor control algorithms but is especially compatible with the three bean salad algorithm discussed by Ball et al. (1991).

  5. Characteristic analysis and experiment of pneumatic servo valve

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Lee, Won Hee; Choi, Byung Oh

    2004-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  6. Monitoring the Inhalation Flow Rate of Nebulized Aerosols Using an Ultrasonic Flow Meter: In Vitro Assessment.

    Science.gov (United States)

    Yang, Michael Y; Chan, Hak-Kim

    2017-06-01

    The measurement of aerosol flow rates without obscuration of the flow is of particular concern with in vivo lung deposition studies, where precise knowledge of aerosol particle size distributions is a necessary requirement for the development of predictive correlations. This study examines the utility of an ultrasonic flow meter for such measurements and determines if a valved system can be attached to the flow meter for sampling exhaled aerosols. The flow rate across a D-30 flow meter was compared with and without nebulization of 0.9% saline aerosols from a PARI LC Sprint nebulizer. Particle size distributions of the nebulized aerosol before and after adding the D-30 flow meter and duckbill valve were measured using a Spraytec laser diffraction system. Finally, the ability of the Thor D-30 to capture a realistic breathing profile was assessed. The mean ± standard error flow rates measured by the D-30 flow meter with and without nebulization were 10.4 ± 0.1 versus 10.4 ± 0.1 L/min, 66.4 ± 0.1 versus 67.2 ± 0.1 L/min, and 89.9 ± 0.1 versus 91.4 ± 0.1 L/min. The D-30 flow meter did not considerably affect the volumetric median diameter (VMD) of the aerosols, while the VMD reduced slightly by 0.65 μm at 10 L/min and 0.69 μm at 72 L/min upon the inclusion of a duckbill valve. Time-weighted average inhalation flow rates measured by D-30 flow meters placed upstream and downstream of the one-way valve agreed well, 31.9 versus 32.6 L/min, respectively. The D-30 flow meter can be used to accurately measure inhalation flow rates of nebulized aerosols without significantly impacting particle size distributions, and one-way duckbill valves can be used to isolate the inhalation portion of a breathing pattern to facilitate collection of exhaled doses.

  7. Electro-Pneumatic Control System with Hydraulically Positioning Actuator Motor

    Directory of Open Access Journals (Sweden)

    V. N. Pilgunov

    2016-01-01

    Full Text Available A compressibility of the actuating fluid of a pneumatic drive (compressed air leads to significant landing of the pneumatic cylinder piston at the time of stop and hold of the load, a constant component of which can fluctuate significantly for the holding period.There are a lot of factors, which have a significant impact on the landing value of piston. Those are: an initial position of the piston at its stop, which determines the volume of the an active area of the piston, a value of the constant load component at the time of stop and its variation for the holding period, a transfer coefficient of the position component of the load, an active area of the pneumatic cylinder piston, as well as reduction in atmospheric pressure, which can significantly affect the operation of the control systems of small aircrafts flying at high altitudes.To reduce the landing value of piston due to changing value of the constant load component for its holding period, it is proposed to use a hydraulic positioner, which comprises a hydraulic cylinder the rod of which is rigidly connected to the rod of the pneumatic cylinder through the traverse, a cross-feed valve of the hydro-cylinder cavities with discrete electro-magnetic control, and adjustable chokes.A programmable logic controller provides the hydraulic positioner control. At the moment the piston stops and the load is held the cross-feed valve overlaps the hydro-cylinder cavities thereby locking the pneumatic cylinder piston and preventing its landing. With available pneumatic cylinder-controlled signal the cross-feed valve connects the piston and rod cavities of the positioner hydro-cylinder, the pneumatic cylinder piston is released and becomes capable of moving.A numerical estimate of landing of the pneumatic cylinder piston and its positioning quality is of essential interest. For this purpose, a technique to calculate the landing of piston has been developed taking into consideration that different

  8. Experimental Investigation on The Electromagnetic Clutch Water pump and Pneumatic Compressor for Improving the Efficiency of an Engine

    Science.gov (United States)

    Kumarasubramanian, R.; Xavier, Goldwin; Nishanthi, W. Mary; Rajasekar, R.

    2017-05-01

    Considering the fuel crises today many work and research were conducted to reduce the fuel consumption of the internal combustion engine. The fuel consumption of an internal combustion engine can be relatively reduced by use of the electromagnetic clutch water pump and pneumatic compressor. Normally in an engine, the water pump is driven by the crankshaft, with an aid of belt, for the circulation of the water for the cooling process. The circulation of coolant is resisted by the thermostat valve, while the temperature inside the coolant jacket of the engine is below 375K the thermostat is closed only above 375K it tends to open. But water pump run continuously even when thermostat is closed. In pneumatic braking system, pneumatic or air compressor purpose is to compress the air and stored into the storage tank for the brake operation. When the air pressure of the storage tanks gets increases above its storage capacity pressure is regulated by governor, by passing them to atmosphere. Such unnecessary work of this water pump and air compressor can be minimized by use of the electromagnetic clutch water pump and air compressor. The European Driving Cycle is used to evaluate the performance of this water pump and air compressor when used in an engine. The result shows that the fuel economy of the engine while using electromagnetic water pump and pneumatic compressor were improved by 8.0% compared with conventional types which already exist. The application of these electromagnetic water pump and pneumatic compressor are expected to contribute for the improvement of engine performance because of their effect in reduction of the rate of fuel consumption.

  9. Dynamic contraction behaviour of pneumatic artificial muscle

    Science.gov (United States)

    Doumit, Marc D.; Pardoel, Scott

    2017-07-01

    The development of a dynamic model for the Pneumatic Artificial Muscle (PAM) is an imperative undertaking for understanding and analyzing the behaviour of the PAM as a function of time. This paper proposes a Newtonian based dynamic PAM model that includes the modeling of the muscle geometry, force, inertia, fluid dynamic, static and dynamic friction, heat transfer and valve flow while ignoring the effect of bladder elasticity. This modeling contribution allows the designer to predict, analyze and optimize PAM performance prior to its development. Thus advancing successful implementations of PAM based powered exoskeletons and medical systems. To date, most muscle dynamic properties are determined experimentally, furthermore, no analytical models that can accurately predict the muscle's dynamic behaviour are found in the literature. Most developed analytical models adequately predict the muscle force in static cases but neglect the behaviour of the system in the transient response. This could be attributed to the highly challenging task of deriving such a dynamic model given the number of system elements that need to be identified and the system's highly non-linear properties. The proposed dynamic model in this paper is successfully simulated through MATLAB programing and validated the pressure, contraction distance and muscle temperature with experimental testing that is conducted with in-house built prototype PAM's.

  10. Design of flat pneumatic artificial muscles

    Science.gov (United States)

    Wirekoh, Jackson; Park, Yong-Lae

    2017-03-01

    Pneumatic artificial muscles (PAMs) have gained wide use in the field of robotics due to their ability to generate linear forces and motions with a simple mechanism, while remaining lightweight and compact. However, PAMs are limited by their traditional cylindrical form factors, which must increase radially to improve contraction force generation. Additionally, this form factor results in overly complicated fabrication processes when embedded fibers and sensor elements are required to provide efficient actuation and control of the PAMs while minimizing the bulkiness of the overall robotic system. In order to overcome these limitations, a flat two-dimensional PAM capable of being fabricated using a simple layered manufacturing process was created. Furthermore, a theoretical model was developed using Von Karman’s formulation for large deformations and the energy methods. Experimental characterizations of two different types of PAMs, a single-cell unit and a multi-cell unit, were performed to measure the maximum contraction lengths and forces at input pressures ranging from 0 to 150 kPa. Experimental data were then used to verify the fidelity of the theoretical model.

  11. Thermo-pneumatic canning; Le gainage thermopneumatique

    Energy Technology Data Exchange (ETDEWEB)

    Gauthron, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    In the thermo-pneumatic canning, the fuel is enclosed in its can with a clearance that must be reduced by external heated gas pressure. The principal applications are: a) binding magnesium cans on to uranium in fuel elements of reactors cooled by CO{sub 2} under pressure, b) application of a can to a hollow bar of uranium too thin to resist the pressure of cold hydraulic canning, c) application of an aluminium can to a bar, with an initial diametrical clearance between uranium and can too great to sustain cold hydraulic canning without buckling, d) detection of major leakage in the slugs. (author) [French] Ce procede consiste a appliquer une gaine sur une barre d'uranium par pression hydrostatique d'un gaz chaud. Les principales applications sont: a) le frettage des gaines de magnesium des elements combustibles des piles refroidies au CO{sub 2} sous pression, b) le gainage d'un barreau creux qui serait ecrase a froid, c) le gainage avec un jeu initial trop fort pour etre effectue a froid sans plisser, d) la detection des fuites de cartouches. (auteur)

  12. Achalasia: pneumatic Dilation. Experience in a reference hospital

    International Nuclear Information System (INIS)

    Garzon, Martin; Farfan, Yezid; Molano, Juan; Rey, Mario; Martinez, Julian; Marulanda, Juan

    2005-01-01

    Chalasia has an incidence of 1:100.000. The therapy for achalasia, focus on reducing the pressure gradient across the LES, which can be achieved by forceful pneumatic dilation of the gastroesophageal junction, surgical myotomy or by pharmacological agents, injected endoscopically or taken orally. Pneumatic balloon dilation is regarded as the first-Line treatment, with an initial success rate of 85% to 90%. The objective of this study is to show our experience with pneumatic balloon dilation in the patients with diagnosis of achalasia from the hospital La Samaritana during a period from February 2002 to February 2005. Patients diagnosed with achalasia from the department of gastroenterology and endoscopy of the Hospital La Samaritana during period of February 2002 to February 2005 was included. Procedures were made in fluoroscopy room. The patients received intravenous sedation and analgesia. We used a Regiflex balloon, 3.5 cm diameter. Balloons were inflated with saline water and water-soluble contrast during one minute. We diagnosed 19 patients with achalasia during period from February 2002 to February 2005, 14 were females and 5 males (26%); we made pneumatic dilation in 11 patients (60%), 9 were females (82%) with mean age 38.9 years (ranged from 16 to 13 years). Three patients (21%) underwent once pneumatic dilation and the rest (8 patients) underwent twice (73%). We don't report any perforation. So far we have followed the patients ambulatory during period from 6 months to 2 years. We find recurrence one year after of the pneumatic dilation in a female patient 22 years old (9%). The pneumatic dilation as cost-effective therapy, with a good initial success, but in the longer the follow-up lower the success rate and low morbidity (4). We suggest making only two pneumatic dilations. Today, there isn't consensus on the optimal endoscopic dilation technique and we believe that the sedation must be included in this procedure. In the future, we need more comparative

  13. Mechanical implications of pneumatic neck vertebrae in sauropod dinosaurs

    Science.gov (United States)

    Schwarz-Wings, Daniela; Meyer, Christian A.; Frey, Eberhard; Manz-Steiner, Hans-Rudolf; Schumacher, Ralf

    2010-01-01

    The pre-sacral vertebrae of most sauropod dinosaurs were surrounded by interconnected, air-filled diverticula, penetrating into the bones and creating an intricate internal cavity system within the vertebrae. Computational finite-element models of two sauropod cervical vertebrae now demonstrate the mechanical reason for vertebral pneumaticity. The analyses show that the structure of the cervical vertebrae leads to an even distribution of all occurring stress fields along the vertebrae, concentrated mainly on their external surface and the vertebral laminae. The regions between vertebral laminae and the interior part of the vertebral body including thin bony struts and septa are mostly unloaded and pneumatic structures are positioned in these regions of minimal stress. The morphology of sauropod cervical vertebrae was influenced by strongly segmented axial neck muscles, which require only small attachment areas on each vertebra, and pneumatic epithelia that are able to resorb bone that is not mechanically loaded. The interaction of these soft tissues with the bony tissue of the vertebrae produced lightweight, air-filled vertebrae in which most stresses were borne by the external cortical bone. Cervical pneumaticity was therefore an important prerequisite for neck enlargement in sauropods. Thus, we expect that vertebral pneumaticity in other parts of the body to have a similar role in enabling gigantism. PMID:19801376

  14. A new pneumatic suspension system with independent stiffness and ride height tuning capabilities

    Science.gov (United States)

    Yin, Zhihong; Khajepour, Amir; Cao, Dongpu; Ebrahimi, Babak; Guo, Konghui

    2012-12-01

    This paper introduces a new pneumatic spring for vehicle suspension systems, allowing independent tuning of stiffness and ride height according to different vehicle operating conditions and driver preferences. The proposed pneumatic spring comprises a double-acting pneumatic cylinder, two accumulators and a tuning subsystem. This paper presents a detailed description of the pneumatic spring and its working principle. The mathematical model is established based on principles of thermo and fluid dynamics. An experimental setup has been designed and fabricated for testing and evaluating the proposed pneumatic spring. The analytical and experimental results confirm the capability of the new pneumatic spring system for independent tuning of stiffness and ride height. The mathematical model is verified and the capabilities of the pneumatic spring are further proved. It is concluded that this new pneumatic spring provides a more flexible suspension design alternative for meeting various conflicting suspension requirements for ride comfort and performance.

  15. Nebulized formoterol: a review of clinical efficacy and safety in COPD

    Directory of Open Access Journals (Sweden)

    Nicholas J Gross

    2010-06-01

    Full Text Available Nicholas J Gross1, James F Donohue21Hines VA Hospital, Stritch Loyola School of Medicine, Hines, IL, USA; 2University of North Carolina School of Medicine, Chapel Hill, NC, USAAbstract: A nebulized formulation of formoterol, Perforomist®, 20 μg/2 ml, has been available since 2007 for the maintenance treatment of chronic obstructive pulmonary disease (COPD. We review the safety and efficacy data obtained during its development. In a dose-finding study, formoterol inhalation solution (FFIS was similar to the formoterol originator, Foradil® 12 μg DPI (FA in patients with COPD. In a 12-week efficacy study, FFIS manifested a rapid onset of action and FEV1 peak, AUC0–12, and trough levels similar to FA. No loss of efficacy, tachyphylaxis, was observed over 12 weeks of regular administration. In placebo-controlled studies in COPD patients receiving maintenance tiotropium, the addition of FFIS significantly augmented bronchodilation over the 6-week treatment duration, signifying that nebulized formoterol can further improve lung function in patients who are receiving tiotropium without an observed increase in adverse reactions. The safety profile of FFIS during 12-week and 1-year studies revealed adverse events that were similar to those of placebo and FA. Cardiac rhythm studies, including frequent ECGs and Holter monitoring, did not indicate any increase in rate or rhythm disturbances greater than placebo or FA. We conclude that maintenance use of Perforomist® is appropriate for patients with COPD who require or prefer a nebulizer for management of their disease.Keywords: long-acting bronchodilator, β-agonist, chronic bronchitis, pulmonary emphysema, Perforomist®, chronic obstructive pulmonary disease

  16. Formulation, Characterization and Pulmonary Deposition of Nebulized Celecoxib Encapsulated Nanostructured Lipid Carriers

    Science.gov (United States)

    Patlolla, Ram R.; Chougule, Mahavir; Patel, Apurva R.; Jackson, Tanise; Tata, Prasad NV; Singh, Mandip

    2010-01-01

    The aim of the current study was to encapsulate celecoxib (Cxb) in the Nanostructured Lipid Carrier (Cxb-NLC) nanoparticles and evaluate the lung disposition of nanoparticles following nebulization in Balb/c mice. Cxb-NLC nanoparticles were prepared with Cxb, Compritol, Miglyol and sodium taurocholate using high-pressure homogenization. Cxb-NLC nanoparticles were characterized for physical and aerosol properties. In-vitro cytotoxicity studies were performed with A549 cells. The lung deposition and pharmacokinetic parameters of Cxb-NLC and Cxb solution (Cxb-Soln) formulations were determined using Inexpose™ system and Pari LC star jet nebulizer. The particle size and entrapment efficiency of Cxb-NLC formulation were 217 ± 20 nm and > 90%, respectively. The Cxb-NLC released the drug in controlled fashion, and in vitro aersolization of Cxb-NLC formulation showed FPF of 75.6 ± 4.6 %, MMAD of 1.6 ±0.13 μm and GSD of 1.2 ± 0.21. Cxb-NLC showed dose and time dependent cytotoxicity against A549 cells. Nebulization of Cxb-NLC demonstrated 4 fold higher AUCt/D in lung tissues compared to Cxb-Soln. The systemic clearance of Cxb-NLC was slower (0.93 L/h) compared to Cxb-Soln (20.03 L/h). Cxb encapsulated NLC were found to be stable and aerodynamic properties were within the respirable limits. Aerosolization of Cxb-NLC improved the Cxb pulmonary bioavailability compared to solution formulation which will potentially lead to better patient compliance with minimal dosing intervals. PMID:20153385

  17. Comparative study of budesonide as a nebulized suspension vs pressurized metered-dose inhaler in adult asthmatics

    DEFF Research Database (Denmark)

    Bisgaard, H; Nikander, K; Munch, E

    1998-01-01

    The study objective was to compare the effect of budesonide administered as a nebulized suspension as compared to a spray with a spacer in adult asthmatics. In a double-blind, double-dummy crossover study, 26 adult patients with moderately severe unstable asthma were randomized to three 4-week...... treatment periods with budesonide 0.8 mg b.i.d. administered by a pressurized metered-dose inhaler (pMDI) with spacer (Nebuhaler) and budesonide 1 mg and 4 mg b.i.d. administered by a Pari Inhalier Boy jet nebulizer. The nebulizer was activated only during inspiration. The total mass output was similar from...... the two devices but their fraction of small particles differed by a factor of 2 in favour of pMDI. Effect was evaluated from daily home measurements of peak expiratory flow (PEF), need of beta 2-agonist and symptom scores. Plasma cortisol and budesonide levels were measured in a subgroup of 10 patients...

  18. Modeling the dynamic characteristics of pneumatic muscle.

    Science.gov (United States)

    Reynolds, D B; Repperger, D W; Phillips, C A; Bandry, G

    2003-03-01

    A pneumatic muscle (PM) system was studied to determine whether a three-element model could describe its dynamics. As far as the authors are aware, this model has not been used to describe the dynamics of PM. A new phenomenological model consists of a contractile (force-generating) element, spring element, and damping element in parallel. The PM system was investigated using an apparatus that allowed precise and accurate actuation pressure (P) control by a linear servo-valve. Length change of the PM was measured by a linear potentiometer. Spring and damping element functions of P were determined by a static perturbation method at several constant P values. These results indicate that at constant P, PM behaves as a spring and damper in parallel. The contractile element function of P was determined by the response to a step input in P, using values of spring and damping elements from the perturbation study. The study showed that the resulting coefficient functions of the three-element model describe the dynamic response to the step input of P accurately, indicating that the static perturbation results can be applied to the dynamic case. This model is further validated by accurately predicting the contraction response to a triangular P waveform. All three elements have pressure-dependent coefficients for pressure P in the range 207 < or = P < or = 621 kPa (30 < or = P < or = 90 psi). Studies with a step decrease in P (relaxation of the PM) indicate that the damping element coefficient is smaller during relaxation than contraction.

  19. A Pneumatic Actuated Microfluidic Beads-Trapping Device

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Guocheng; Cai, Ziliang; Wang, Jun; Wang, Wanjun; Lin, Yuehe

    2011-08-20

    The development of a polydimethylsiloxane (PDMS) microfluidic microbeads trapping device is reported in this paper. Besides fluid channels, the proposed device includes a pneumatic control chamber and a beads-trapping chamber with a filter array structure. The pneumatic flow control chamber and the beads-trapping chamber are vertically stacked and separated by a thin membrane. By adjusting the pressure in the pneumatic control chamber, the membrane can either be pushed against the filter array to set the device in trapping mode or be released to set the device in releasing mode. In this paper, a computational fluid dynamics simulation was conducted to optimize the geometry design of the filter array structure; the device fabrication was also carried out. The prototype device was tested and the preliminary experimental results showed that it can be used as a beads-trapping unit for various biochemistry and analytical chemistry applications, especially for flow injection analysis systems.

  20. An ankle-foot orthosis powered by artificial pneumatic muscles.

    Science.gov (United States)

    Ferris, Daniel P; Czerniecki, Joseph M; Hannaford, Blake

    2005-05-01

    We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury.

  1. Model analysis of mechanisms controlling pneumatic soil vapor extraction

    DEFF Research Database (Denmark)

    Høier, Camilla Kruse; Sonnenborg, Torben Obel; Jensen, Karsten Høgh

    2009-01-01

    of heterogeneous soils by enforcing large fluctuating pressure fronts through the contaminated area. Laboratory experiments have suggested that pneumatic SVE considerably improves the recovery rate from low-permeable units. We have analyzed the experimental results using a numerical code and quantified......The efficiency of traditional soil venting or soil vapor extraction (SVE) highly depends on the architecture of the subsurface because imposed advective air flow tends to bypass low-permeable contaminated areas. Pneumatic SVE is a technique developed to enhance remediation efficiency...... level the pneumatic venting technology is superior to the traditional technique, and that the method is particularly efficient in cases where large permeability contrasts exist between soil units in the subsurface....

  2. Parallel path nebulizer: Critical parameters for use with microseparation techniques combined with inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Yanes, Enrique G.; Miller-Ihli, Nancy J.

    2005-01-01

    Four different, low flow parallel path Mira Mist CE nebulizers were evaluated and compared in support of an ongoing project related to the use of microseparation techniques interfaced to inductively coupled plasma mass spectrometry for the quantification of cobalamin species (Vitamin B12). For the characterization of the different Mira Mist CE nebulizers, the nebulizer orientation as well as the effect of methanol on analytical response was the focus of the study. The position of the gas outlet on the nebulizer which consistently provided the maximum signal was when it was rotated to the 11 o'clock position when the nebulizer is viewed end-on. With this orientation the increased signal may be explained by the fact that the cone angle of the aerosol is such that the largest percentage of the aerosol is directed to the center of the spray chamber and consequently into the plasma. To characterize the nebulizer's performance, the signal response of a multielement solution containing elements with a variety of ionization potentials was used. The selection of elements with varying ionization energies and degrees of ionization was essential for a better understanding of observed increases in signal enhancement when methanol was used. Two different phenomena contribute to signal enhancement when using methanol: the first is improved transport efficiency and the second is the 'carbon enhancement effect'. The net result was that as much as a 30-fold increase in signal was observed for As and Mg when using a make-up solution of 20% methanol at a 15 μL/min flow rate which is equivalent to a net volume of 3 μL/min of pure methanol

  3. Development of a direct hydride generation nebulizer for the determination of selenium by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Carrion, Nereida; Murillo, Miguel; Montiel, Edie; Diaz, Dorfe

    2003-01-01

    A study was conducted to evaluate the performance of a new direct hydride generation nebulizer system for determination of hydride forming elements by inductively coupled plasma optical emission spectroscopy. This system was designed and optimized to obtain the highest sensitivity. Several experimental designs were used for these purposes. To optimize the individual parameters of the system, and to study the interaction between these parameters for both direct hydride generation nebulizers, a central composite orthogonal design with eight factors was set up. Significant behavioral differences were observed in the two direct hydride generation nebulizers studied. Finally, a 70 μm gas orifice nebulizer exhibits a better detection limit than the 120 μm nebulizer. Generally, for determination of selenium, this new direct hydride generation nebulizer system exhibits a linear dynamic range and detection limit (3σb) of 3 orders of magnitude and 0.2 μg l -1 for selenium, respectively. This new hydride generator is much simpler system that conventional hydride generation systems, which does not need to be changed to work in normal mode with the inductively coupled plasma, since this system may be used for hydride forming elements and those that do not form them. It produces a rapid response with low memory effect. It reduces the interference level of Ni, Co and Cu to 600, 500 and 5 mg l -1 , respectively. The accuracy of the system was verified by the determination of selenium in several standard reference materials of ambient, food and clinical sample matrices. No statistically significant differences (95 confidence level) were obtained between our method and the reference values

  4. Second Order Sliding Mode Controller Design for Pneumatic Artificial Muscle

    Directory of Open Access Journals (Sweden)

    Ammar Al-Jodah

    2018-01-01

    Full Text Available In this paper, first and second order sliding mode controllers are designed for a single link robotic arm actuated by two Pneumatic Artificial Muscles (PAMs. A new mathematical model for the arm has been developed based on the model of large scale pneumatic muscle actuator model. Uncertainty in parameters has been presented and tested for the two controllers. The simulation results of the second-order sliding mode controller proves to have a low tracking error and chattering effect as compared to the first order one. The verification has been done by using MATLAB and Simulink software.

  5. Nonlinear Disturbance Observer Based Robust Tracking Control of Pneumatic Muscle

    Directory of Open Access Journals (Sweden)

    Youssif Mohamed Toum Elobaid

    2014-01-01

    Full Text Available Presently pneumatic muscles (PMs are used in various applications due to their simple construction, lightweight, and high force-to-weight ratio. However, pneumatic muscles are facing various problems due to their nonlinear characteristics and various uncertainties in real applications. To cope with the uncertainties and strong nonlinearity of a PM model, a nonlinear disturbance observer (NDO is designed to estimate the lumped disturbance. Based on the disturbance observer, the tracking control of PM is studied. Stability analysis based on Lyapunov method with respect to our proposed control law is discussed. The simulation results show the validity, effectiveness, and enhancing robustness of the proposed methods.

  6. An artificial flexible robot arm based on pneumatic muscle actuators

    Directory of Open Access Journals (Sweden)

    Renn Jyh-Chyang

    2017-01-01

    Full Text Available The purpose of this paper is to develop a novel human-friendly artificial flexible robot arm using four parallel-connected pneumatic muscle actuators (PMAs. The PMA is a flexible silicone rubber actuator which has some behaviors nearest to the real biological muscle including translational and rotational motions. An inverse kinematic model for the motion control is also developed. Finally, from experiment results, it is proved that not only the axial contraction control of a single PMA but also the attitude control of the whole pneumatic flexible robot arm using PID controller are satisfactory.

  7. Control of pneumatic transfer system for neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jung, H. S.; Chung, Y. S.; Wu, J. S.; Kim, H. K.; Choi, Y. S.; Kim, S. H.; Moon, J. H.; Baek, S. Y

    2000-06-01

    Pneumatic transfer system(PTS) is one of the facilities to be used in irradiation of target materials for neutron activation analysis(NAA) in the research reactor. There are two systems the manual and the automatic system in PTS of HANARO research reactor. The pneumatic transfer system consists of many devices, sends and loads the capsules from NAA laboratory into three holes in the reflector tank of reactor and retrieves irradiated capsules after irradiation. This report describes the part's design, control system and the operation procedures. All the algorithm described in the text will be used for maintenance and upgrading.

  8. Empirical Analysis of Pneumatic Tire Friction on Ice

    OpenAIRE

    Holley, Troy Nigel

    2010-01-01

    Pneumatic tire friction on ice is an under-researched area of tire mechanics. This study covers the design and analysis of a series of pneumatic tire tests on a flat-level ice road surface. The terramechanics rig of the Advanced Vehicle Dynamics Lab (AVDL) is a single-wheel test rig that allows for the experimental analysis of the forces and moments on a tire, providing directly the data for the drawbar pull of said tire, thus supporting the calculation of friction based on this data. This...

  9. Electro-Pneumatic Control System with Hydraulically Positioning Actuator Motor

    OpenAIRE

    V. N. Pilgunov; K. D. Efremova

    2016-01-01

    A compressibility of the actuating fluid of a pneumatic drive (compressed air) leads to significant landing of the pneumatic cylinder piston at the time of stop and hold of the load, a constant component of which can fluctuate significantly for the holding period.There are a lot of factors, which have a significant impact on the landing value of piston. Those are: an initial position of the piston at its stop, which determines the volume of the an active area of the piston, a value of the con...

  10. Control of pneumatic transfer system for neutron activation analysis

    International Nuclear Information System (INIS)

    Jung, H. S.; Chung, Y. S.; Wu, J. S.; Kim, H. K.; Choi, Y. S.; Kim, S. H.; Moon, J. H.; Baek, S. Y.

    2000-06-01

    Pneumatic transfer system(PTS) is one of the facilities to be used in irradiation of target materials for neutron activation analysis(NAA) in the research reactor. There are two systems the manual and the automatic system in PTS of HANARO research reactor. The pneumatic transfer system consists of many devices, sends and loads the capsules from NAA laboratory into three holes in the reflector tank of reactor and retrieves irradiated capsules after irradiation. This report describes the part's design, control system and the operation procedures. All the algorithm described in the text will be used for maintenance and upgrading

  11. On the sample transport time of a pneumatic transfer system

    International Nuclear Information System (INIS)

    Kondo, Yoshihide

    1983-01-01

    The counts accumulated in measuring system are affected by the variations in transport time of the sample on cyclic activation experiments with a mechanical sample transfer system. In use of the pneumatic transfer system, which has been set up, the transport time is variable according to the differences as follows: The form, size and weight of samples, the pneumatic pressure and so on. Comprehending the relationships between the transpot time and these variable factors is essentially important to make experiments with this transfer system. (author)

  12. Placebo-controlled trial of nebulization with adrenaline in acute bronchiolitis: a quasi-experimental study

    International Nuclear Information System (INIS)

    Afzal, M.F.; Iqbal, S.M.; Sultan, M.A.

    2012-01-01

    Background: Bronchiolitis is an acute inflammatory obstruction. of small In children that occurs In first two years of life and is by fever, rhinitis, cough, tachypnoea, expiratory wheeze and increased respiratory effort To study efficacy of nebulized adrenaline compared with placebo in acute bronchiolitis. Quasi-experimental study carried out at Department of aediatrics, King Edward Medical University/ Mayo Hospital, Lahore from October 2006 through March 2007. After consent from parents, sixty children of age between 2 months to 2 years with the first episode consistent with clinical case definition of bronchiolitis were included by using convenient sampling. clinical scoring system was used to grade the severity of disease as well as to monitor the efficacy of intervention. Those having score = 8 were randomly allocated to the two study groups. The information was recorded at 0 minute and effect of each method of treatment was followed for 90 minutes. Results: Our study population was 60 children. The mean age was 11:1:6 Months. Male to female ratio was 1.2: 1. Mean weight of the Children was 9:1:3 kg. Improvement in clinical score, oxygen saturation, and length of hospital at 0 and 90 minutes was noted in both groups but when compared with placebo, there was no Statistically significant difference. Conclusion: There is no difference in the efficacy of nebulization with adrenaline compared with placebo in the management of acute bronchiolitis. (author)

  13. Ultrasonic Nebulizer Assisted LIBS: a Promising Metal Elements Detection Method for Aqueous Sample Analysis

    International Nuclear Information System (INIS)

    Zhong Shilei; Zheng Ronger; Lu Yuan; Cheng Kai; Xiu Junshan

    2015-01-01

    A newly developed approach for trace metal elements detection for aqueous samples analysis is presented in this paper. The idea of this approach is to improve ablation efficiency by transforming the liquid sample into a dense cloud of droplets using an ultrasonic nebulizer. The resulting droplets are then subjected to analysis by laser induced breakdown spectroscopy (LIBS). A purpose-built ultrasonic nebulizer assisted LIBS (UN-LIBS) system has been applied to the analysis of aqueous samples at trace levels of concentration. Experimental investigations of solution samples were carried out with various dissolved trace metal elements (Mn, Zn, Cu, Pb, Fe, Mg and Na) using this approach. The characteristics of UN-LIBS signal of the elements were investigated regarding the lifetime and S/B ratio and the calibration curves for trace metal elements analyses. The obtained LODs are comparable or much better than the LODS of the reported signal enhancement approaches when the laser pulse energy was as low as 30 mJ. The good linearity of calibration curves and the low LODs shows the potential ability of this method for metal elements analysis application. The density of the electrons was calculated by measuring the Stark width of the line of H α . The possible mechanism of the LIBS signal enhancement of this approach was briefly discussed. (paper)

  14. Nebulized hypertonic saline decreases IL-8 in sputum of patients with cystic fibrosis.

    LENUS (Irish Health Repository)

    Reeves, Emer P

    2012-02-01

    RATIONALE: Inflammation within the cystic fibrosis (CF) lung is mediated by inflammatory chemokines, such as IL-8. IL-8 is protected from proteolytic degradation in the airways by binding to glycosaminoglycans, while remaining active. Evidence that increased hypertonicity of airway secretions induced by hypertonic saline treatment alters levels of IL-8 is lacking. OBJECTIVES: To investigate the antiinflammatory effect of hypertonic saline (HTS) treatment within the CF lung by focusing on IL-8. METHODS: Degradation of IL-8 in CF lung secretions after treatment with glycosaminoglycan lyases and HTS was analyzed by Western blot analysis and ELISA. The ex vivo chemotactic activity of purified neutrophils in response to CF airway secretions was evaluated post nebulization of HTS (7% saline). MEASUREMENTS AND MAIN RESULTS: In vivo CF bronchoalveolar lavage fluid (BALF) IL-8 levels were significantly higher than the control group (P < 0.05). Digesting glycosaminoglycans in CF BALF displaced IL-8 from glycosaminoglycan matrices, rendering the chemokine susceptible to proteolytic cleavage. High sodium concentrations also liberate IL-8 in CF BALF in vitro, and in vivo in CF sputum from patients receiving aerosolized HTS, resulting in degradation of IL-8 and decreased neutrophil chemotactic efficiency. CONCLUSIONS: Glycosaminoglycans possess the ability to influence the chemokine profile of the CF lung by binding and stabilizing IL-8, which promotes neutrophil chemotaxis and activation. Nebulized hypertonic saline treatment disrupts the interaction between glycosaminoglycans and IL-8, rendering IL-8 susceptible to proteolytic degradation with subsequent decrease in neutrophil chemotaxis, thereby facilitating resolution of inflammation.

  15. Comparison of aerosol inhalation lung images using BARC and other nebulizers

    International Nuclear Information System (INIS)

    Isawa, Toyoharu; Teshima, Takeo; Anazawa, Yoshiki; Miki, Makoto

    1994-01-01

    Various factors determine the site of inhaled aerosol deposition in the lungs. They are the size of aerosol the composition of carrier gas of the aerosol, the airflow rate, physico-chemical properties of the carrier gas or the aerosol, the shape and structure of the airways, and the body position during inhalation. Aerosol inhalation lung images were obtained in the same subjects using 99m Tc-human serum albumin aerosol generated by 3 different aerosol generators each producing different-sized aerosol and 2 or 3 days apart from each study. The size of aerosol produced by an ultrasonic nebulizer (Mistogen) was 1.93 Micron in activity median aerodynamic diameter (AMAD) with its geometric standard deviation (σg) of 1.73, that by a jet nebulizer (Ultra Vent) was 1.04 micron in AMAD with its σg of 1.71, and that by our BARC nebulizer, a type of a jet nebulizer, was 0.84 micron in AMAD with its σg of 1.73. In addition Technegas was also applied to selected patients. The latter produced aerosol of less than 0.2 micron in size at the largest and the majority, say, 95% or more of the generated aerosol was less than 0.1 micron in size by electron Microscopy. Each subject inhaled aerosol in resting tidal breathing through a mouth-piece with a one way double J valve with the nose clipped in the sitting position. After inhaling approximately 2-3 mCi (74 to 111 MBq) in the thorax, four view lung images were taken: anterior, posterior, and right and left laterals. 300 K counts per view were collected. They were not only pictured on polaroid films as analogue data but also recorded and stored in a computer as digital data. In case of Technegas breathing it for the RV (residual volume) to the TLC (total lung capacity) level followed by breath-holding for 5 to 10 sec in duration was repeated 2 to 3 times as a breathing maneuver instead of tidal breathing. Otherwise deposition efficiency of Technegas is very little because of the small size of the Technegas. Representative 10

  16. Design considerations for single-stage and two-stage pneumatic pellet injectors

    International Nuclear Information System (INIS)

    Gouge, M.J.; Combs, S.K.; Fisher, P.W.; Milora, S.L.

    1988-09-01

    Performance of single-stage pneumatic pellet injectors is compared with several models for one-dimensional, compressible fluid flow. Agreement is quite good for models that reflect actual breech chamber geometry and incorporate nonideal effects such as gas friction. Several methods of improving the performance of single-stage pneumatic pellet injectors in the near term are outlined. The design and performance of two-stage pneumatic pellet injectors are discussed, and initial data from the two-stage pneumatic pellet injector test facility at Oak Ridge National Laboratory are presented. Finally, a concept for a repeating two-stage pneumatic pellet injector is described. 27 refs., 8 figs., 3 tabs

  17. Controlling pneumatic artificial muscles in exoskeletons with surface electromyography

    NARCIS (Netherlands)

    Groenhuis, Vincent; Chandrapal, Mervin; Stramigioli, Stefano; Chen, XiaoQi

    2014-01-01

    Powered exoskeletons are gaining more interest in the last few years, as useful devices to provide assistance to elderly and disabled people. Many different types of powered exoskeletons have been studied in the past. In this research paper, a soft lower limb exoskeleton driven by pneumatic

  18. Pneumatic conveying of sensitive compounds during nuclear fuel fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Sielck, Franz-Christian; Braehler, Georg [NUKEM Technologies GmbH (Germany)

    2009-07-01

    Any transport of nuclear material is associated with the risk of contamination after release into working areas or environment. stationary installed safe geometry vessels with pneumatic transfer between them offer unique safety features and reduce operating costs. The article describes the case of HTR fuel spheres, where a specially designed conveying system has been developed and the prototype conveyor has been tested.

  19. Pneumatic conveying of sensitive compounds during nuclear fuel fabrication

    International Nuclear Information System (INIS)

    Sielck, Franz-Christian; Braehler, Georg

    2009-01-01

    Any transport of nuclear material is associated with the risk of contamination after release into working areas or environment. stationary installed safe geometry vessels with pneumatic transfer between them offer unique safety features and reduce operating costs. The article describes the case of HTR fuel spheres, where a specially designed conveying system has been developed and the prototype conveyor has been tested.

  20. Systems of pneumatic transportation of cement and other fine ...

    African Journals Online (AJOL)

    Therefore, the operational reliability of such equipment decreases and the process of cleaning of the exhaust air becomes complicated. The solution of the problem of ... of the air expense and pressure during the design of the systems. Keywords: pneumatic transportation, fine materials. dust removal equipment, pape line.

  1. Rapid Prototyping High-Performance MR Safe Pneumatic Stepper Motors

    NARCIS (Netherlands)

    Groenhuis, Vincent; Stramigioli, Stefano

    2018-01-01

    In this paper we show that pneumatic stepper motors for MR safe robots can be constructed using rapid prototyping techniques such as 3-D printing and laser-cutting. The designs are lightweight, completely metal-free and fully customizable. Besides MR safe robotic systems, other potential

  2. Considerations of several real effects in pneumatic pellet injection processes

    International Nuclear Information System (INIS)

    Ming-Lun Xue.

    1987-10-01

    Several real effects that take place in a pneumatic pellet injector are examined. These are the heat transfer between a high-temperature propellent gas and the metal wall of the injector, and the frictional loss between the propellent and wall. (author)

  3. Pneumatic Dilation versus Laparoscopic Heller's Myotomy for Idiopathic Achalasia

    NARCIS (Netherlands)

    Boeckxstaens, Guy E.; Annese, Vito; des Varannes, Stanislas Bruley; Chaussade, Stanislas; Costantini, Mario; Cuttitta, Antonello; Elizalde, J. Ignasi; Fumagalli, Uberto; Gaudric, Marianne; Rohof, Wout O.; Smout, André J.; Tack, Jan; Zwinderman, Aeilko H.; Zaninotto, Giovanni; Busch, Olivier R.; Lei, A.; Bartelsman, J.; Hirsch, D.; Klinkenberg-Knol, E. C.; Cuesta, M. A.; Simmermacher, R. K. J.; Kuipers, E. J.; Bonjer, H. J.; Masclee, A. A. M.; Ringers, J.; Lerut, A.; Metman, E. H.; Huten, N.; Letessier, E.; Dousset, B.; Pera, M.; Perez de la Serna, J.; Malesci, Alberto; Andriulli, A.; Scaramuzzi, G.; de Santo, E.

    2011-01-01

    Background Many experts consider laparoscopic Heller's myotomy (LHM) to be superior to pneumatic dilation for the treatment of achalasia, and LHM is increasingly considered to be the treatment of choice for this disorder. Methods We randomly assigned patients with newly diagnosed achalasia to

  4. Intra-operative pneumatic tourniquet - perceptions of use and ...

    African Journals Online (AJOL)

    applied pressure alone or excessive applied pressure caused by use of faulty equipment. It needs to be emphasised to these surgeons that regular checking of the pneumatic tourniquet apparatus is necessary in order. MRC/UCT Bioenergetics of Exercise Research Unit, Department of. Physiology. University of Cape Town.

  5. Intra-operative pneumatic tourniquet - perceptions of use and ...

    African Journals Online (AJOL)

    Fifty-four per cent of respondents personally checked the calibration of the pneumatic tourniquet, although 76% of respondents believe that the apparatus needs to be checked at least once per month. More respondents who did not check the tourniquet apparatus than respondents who did check it believe that applied ...

  6. Pneumatic Actuation of a 2-Link Robotic System

    African Journals Online (AJOL)

    2012r

    2014-10-16

    Oct 16, 2014 ... are appropriate for “mixing, dumping, intermittent feeding, screw clamping ..... Let Aext be Area on which air is applied for extension. Let Aret ... Fext and Fret are the forces provided by the source of the pneumatic compressor.

  7. Transport Velocities of Different Particulate Materials in Pneumatic Conveying

    Czech Academy of Sciences Publication Activity Database

    Hartman, Miloslav; Pohořelý, Michael; Trnka, Otakar

    2006-01-01

    Roč. 60, č. 1 (2006), s. 74-77 ISSN 0366-6352 R&D Projects: GA AV ČR(CZ) IAA4072201 Institutional research plan: CEZ:AV0Z40720504 Keywords : fluidization * particle processing * pneumatic conveying Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 0.360, year: 2006

  8. Embedded Triboelectric Active Sensors for Real-Time Pneumatic Monitoring.

    Science.gov (United States)

    Fu, Xian Peng; Bu, Tian Zhao; Xi, Feng Ben; Cheng, Ting Hai; Zhang, Chi; Wang, Zhong Lin

    2017-09-20

    Pneumatic monitoring sensors have great demands for power supply in cylinder systems. Here, we present an embedded sliding triboelectric nanogenerator (TENG) in air cylinder as active sensors for position and velocity monitoring. The embedded TENG is composed of a circular poly(tetrafluoroethylene) polymer and a triangular copper electrode. The working mechanism as triboelectric active sensors and electric output performance are systematically investigated. By integrating into the pneumatic system, the embedded triboelectric active sensors have been used for real-time air pressure/flow monitoring and energy storage. Air pressures are measured from 0.04 to 0.12 MPa at a step of 0.02 MPa with a sensitivity of 49.235 V/MPa, as well as airflow from 50 to 250 L/min at a step of 50 L/min with a sensitivity of 0.002 μA·min/L. This work has first demonstrated triboelectric active sensors for pneumatic monitoring and may promote the development of TENG in intelligent pneumatic system.

  9. High Efficiency Pneumatic Systems Compressors Hydrodynamics and Termodynamics Process Research

    Directory of Open Access Journals (Sweden)

    Paulius Bogdevičius

    2016-12-01

    Full Text Available The paper analyzes pneumatic system, which consists of three piston compressors, pipes and reciever. Designed two cylinder piston compressor with an asynchronous electric motor mathematical model. In the mathematical model has been estimated rod mechanism geometry and kinematic parameters also hudrodynamics and thermodynamic processes going in the cylinders. Also there were made mathematical experiment and presented the results of it.

  10. Pneumatic motor speed control by trajectory tracking fuzzy logic

    Indian Academy of Sciences (India)

    In this study, trajectory tracking fuzzy logic controller (TTFLC) is proposed for the speed control of a pneumatic motor (PM). A third order trajectory is defined to determine the trajectory function that has to be tracked by the PM speed. Genetic algorithm (GA) is used to find the TTFLC boundary values of membership functions ...

  11. Progress in ultrasonic spray pyrolysis for condensed matter sciences developed from ultrasonic nebulization theories since Michael Faraday

    CSIR Research Space (South Africa)

    Mwakikunga, BW

    2014-01-01

    Full Text Available This review outlines, in great detail, the history of the phenomenon of ultrasonic nebulization of liquids since the discovery of such an effect by Michael Faraday and the explanation of the phenomenon by capillary wave mechanism and “cavitation...

  12. Integration of Pneumatic Technology in Powered Mobility Devices.

    Science.gov (United States)

    Daveler, Brandon; Wang, Hongwu; Gebrosky, Benjamin; Grindle, Garrett G; Schneider, Urs; Cooper, Rory A

    2017-01-01

    Advances in electric motors, electronics, and control systems have enhanced the capability and drivability of electric power mobility devices over the last 60 years. Yet, battery technologies used in powered mobility devices (PMDs) have not kept pace. Recent advances in pneumatic technology, primarily the high torque, low speed design of rotary piston air motors, directly align with the needs of PMD. Pneumatic technology has advantages over battery-powered technology, including lighter weight, lower operating costs, decreased environmental impact, better reliability, and increased safety. Two prototypes were created that incorporated rotary piston air motors, high-pressure air tanks, and air-pressure regulators. Prototype 1 was created by modifying an existing electric PMD. Range tests were performed to determine the feasibility of pneumatic technology and the optimal combination of components to allow the longest range possible at acceptable speeds over ideal conditions. Using a 1.44 L air tank for feasibility testing, prototype 1 was capable of traveling 800 m, which confirmed the feasibility of pneumatic technology usage in PMDs. Prototype 2 was designed based on the testing results from prototype 1. After further optimization of prototype 2, the average maximum range was 3,150 m. Prototype 2 is up to 28.3% lighter than an equivalent size electric PMD and can be fully recharged in approximately 2 minutes. It decreases the cost of PMDs by approximately $1,500, because batteries do not need to be replaced over the lifetime of the device. The results provide justification for the use of pneumatic technology in PMDs.

  13. Preventive nebulization of mucolytic agents and bronchodilating drugs in invasively ventilated intensive care unit patients (NEBULAE): study protocol for a randomized controlled trial.

    Science.gov (United States)

    van der Hoeven, Sophia M; Binnekade, Jan M; de Borgie, Corianne A J M; Bosch, Frank H; Endeman, Henrik; Horn, Janneke; Juffermans, Nicole P; van der Meer, Nardo J M; Merkus, Maruschka P; Moeniralam, Hazra S; van Silfhout, Bart; Slabbekoorn, Mathilde; Stilma, Willemke; Wijnhoven, Jan Willem; Schultz, Marcus J; Paulus, Frederique

    2015-09-02

    Preventive nebulization of mucolytic agents and bronchodilating drugs is a strategy aimed at the prevention of sputum plugging, and therefore atelectasis and pneumonia, in intubated and ventilated intensive care unit (ICU) patients. The present trial aims to compare a strategy using the preventive nebulization of acetylcysteine and salbutamol with nebulization on indication in intubated and ventilated ICU patients. The preventive nebulization of mucolytic agents and bronchodilating drugs in invasively ventilated intensive care unit patients (NEBULAE) trial is a national multicenter open-label, two-armed, randomized controlled non-inferiority trial in the Netherlands. Nine hundred and fifty intubated and ventilated ICU patients with an anticipated duration of invasive ventilation of more than 24 hours will be randomly assigned to receive either a strategy consisting of preventive nebulization of acetylcysteine and salbutamol or a strategy consisting of nebulization of acetylcysteine and/or salbutamol on indication. The primary endpoint is the number of ventilator-free days and surviving on day 28. Secondary endpoints include ICU and hospital length of stay, ICU and hospital mortality, the occurrence of predefined pulmonary complications (acute respiratory distress syndrome, pneumonia, large atelectasis and pneumothorax), and the occurrence of predefined side effects of the intervention. Related healthcare costs will be estimated in a cost-benefit and budget-impact analysis. The NEBULAE trial is the first randomized controlled trial powered to investigate whether preventive nebulization of acetylcysteine and salbutamol shortens the duration of ventilation in critically ill patients. NCT02159196, registered on 6 June 2014.

  14. Practical controller design for ultra-precision positioning of stages with a pneumatic artificial muscle actuator

    Science.gov (United States)

    Tang, T. F.; Chong, S. H.

    2017-06-01

    This paper presents a practical controller design method for ultra-precision positioning of pneumatic artificial muscle actuator stages. Pneumatic artificial muscle (PAM) actuators are safe to use and have numerous advantages which have brought these actuators to wide applications. However, PAM exhibits strong non-linear characteristics, and these limitations lead to low controllability and limit its application. In practice, the non-linear characteristics of PAM mechanism are difficult to be precisely modeled, and time consuming to model them accurately. The purpose of the present study is to clarify a practical controller design method that emphasizes a simple design procedure that does not acquire plants parameters modeling, and yet is able to demonstrate ultra-precision positioning performance for a PAM driven stage. The practical control approach adopts continuous motion nominal characteristic trajectory following (CM NCTF) control as the feedback controller. The constructed PAM driven stage is in low damping characteristic and causes severe residual vibration that deteriorates motion accuracy of the system. Therefore, the idea to increase the damping characteristic by having an acceleration feedback compensation to the plant has been proposed. The effectiveness of the proposed controller was verified experimentally and compared with a classical PI controller in point-to-point motion. The experiment results proved that the CM NCTF controller demonstrates better positioning performance in smaller motion error than the PI controller. Overall, the CM NCTF controller has successfully to reduce motion error to 3µm, which is 88.7% smaller than the PI controller.

  15. Intramuscular pressures in antigravity muscles using gravity-independent, pneumatic hardware.

    Science.gov (United States)

    Macias, Brandon R; Minocha, Ranjeet; Cutuk, Adnan A; Hill, James; Shiau, Jonathon; Hargens, Alan R

    2008-08-01

    Resistive exercise helps prevent muscle atrophy in microgravity, but better exercise equipment is needed. Therefore, the purpose of this study was to determine if a pneumatic, gravity-independent leg-press device (LPD) provides sufficient force to leg musculature. We hypothesized that intramuscular pressure (IMP), a quantitative index of muscle force, is greater in the antigravity superficial posterior and deep posterior compartments than in the non-antigravity anterior compartment during bilateral leg-press exercise. Millar pressure transducers were inserted into the anterior, lateral, superficial posterior, and deep posterior muscle compartments of the left leg of eight healthy subjects (three women, five men). Subjects were supine on the Keiser SX-1, a pneumatic LPD. Then maximal voluntary contraction (MVC) was determined; each subject performed three consecutive voluntary contractions at approximately 18%, 50%, and 100% MVC while continuously measuring IMP. Repeated measures ANOVA were used to determine differences of IMPs between compartments and loads. The magnitudes of IMP (mean +/- SEM) at 18 - 3% (abbreviated approximately 18%), 50%, and 100% MVC in the superficial and deep posterior compartments were significantly greater than that in the anterior compartment during exercise (P antigravity compartments as compared to the non-antigravity compartment. Since antigravity muscles of the leg are contained primarily in the superficial and deep posterior compartments, the LPD may help prevent muscle atrophy associated with microgravity.

  16. Pneumatic fractures in Confined Granular Media

    Science.gov (United States)

    Eriksen, Fredrik K.; Toussaint, Renaud; Jørgen Måløy, Knut; Grude Flekkøy, Eirik; Turkaya, Semih

    2016-04-01

    We will present our ongoing study of the patterns formed when air flows into a dry, non-cohesive porous medium confined in a horizontal Hele-Shaw cell. This is an optically transparent system consisting of two glass plates separated by 0.5 to 1 mm, containing a packing of dry 80 micron beads in between. The cell is rectangular and has an air-permeable boundary (blocking beads) at one short edge, while the other three edges are completely sealed. The granular medium is loosely packed against the semi-permeable boundary and fills about 80 % of the cell volume. This leaves an empty region at the sealed side, where an inlet allows us to set and maintain the air at a constant overpressure (0.1 - 2 bar). For the air trapped inside the cell to relax its overpressure it has to move through the deformable granular medium. Depending on the applied overpressure and initial density of the medium, we observe a range of different behaviors such as seepage through the pore-network with or without an initial compaction of the solid, formation of low density bubbles with rearrangement of particles, granular fingering/fracturing, and erosion inside formed channels/fractures. The experiments are recorded with a high-speed camera at a framerate of 1000 images/s and a resolution of 1024x1024 pixels. We use various image processing techniques to characterize the evolution of the air invasion patterns and the deformations in the surrounding material. The experiments are similar to deformation processes in porous media which are driven by pore fluid overpressure, such as mud volcanoes and hydraulic or pneumatic (gas-induced) fracturing, and the motivation is to increase the understanding of such processes by optical observations. In addition, this setup is an experimental version of the numerical models analyzed by Niebling et al. [1,2], and is useful for comparison with their results. In a directly related project [3], acoustic emissions from the cell plate are recorded during

  17. Promoting adherence to nebulized therapy in cystic fibrosis: poster development and a qualitative exploration of adherence

    Directory of Open Access Journals (Sweden)

    Jones S

    2015-08-01

    Full Text Available Stephen Jones,1 Nathan Babiker,2 Emma Gardner,2,3 Jane Royle,2 Rachael Curley,3,4 Zhe Hui Hoo,3,4 Martin J Wildman3,4 1Psychology Department, University of Sheffield, 2Psychological Services, Sheffield Teaching Hospitals NHS Foundation Trust, 3Adult Cystic Fibrosis Unit, Northern General Hospital, 4School of Health and Related Research (ScHARR, University of Sheffield, Sheffield, UK Background: Cystic fibrosis (CF health care professionals recognize the need to motivate people with CF to adhere to nebulizer treatments, yet little is known about how best to achieve this. We aimed to produce motivational posters to support nebulizer adherence by using social marketing involving people with CF in the development of those posters. Methods: The Sheffield CF multidisciplinary team produced preliminary ideas that were elaborated upon with semi-structured interviews among people with CF to explore barriers and facilitators to the use of nebulized therapy. Initial themes and poster designs were refined using an online focus group to finalize the poster designs. Results: People with CF preferred aspirational posters describing what could be achieved through adherence in contrast to posters that highlighted the adverse consequences of nonadherence. A total of 14 posters were produced through this process. Conclusion: People with CF can be engaged to develop promotional material to support adherence, providing a unique perspective differing from that of the CF multidisciplinary team. Further research is needed to evaluate the effectiveness of these posters to support nebulizer adherence. Keywords: behavior change, social marketing, patient participation, nebulizers, medication adherence

  18. JHKL photometry of three Herbig-Haro jet sources and a nebulous T Tauri star

    International Nuclear Information System (INIS)

    Vrba, F.J.; Rydgren, A.E.; Zak, D.S.; Computer Sciences Corp., Baltimore, MD; Rensselaer Polytechnic Institute, Troy, NY)

    1985-01-01

    Infrared sources have been detected at the positions of the Herbig-Haro jet sources HH 30, DG Tau B, and Haro 6-5 B in the Taurus dark cloud complex. The colors of these Herbig-Haro jet sources in the 1-4 micron wavelength range are comparable to those of the dustiest T Tauri stars, while the K magnitudes corrected for likely interstellar extinction are actually somewhat fainter than those oftypical T Tauri stars in this region. These observations are consistent with the view that these Herbig-Haro jet sources are low-mass premain-sequence stars. The nebulous T Tauri star Haro 6-5 was also observed and found to show both a large infrared excess and an intrinsic-polarization of about 3 percent in visible light. Thus this star seems to resemble HL Tau and DG Tau, which have been suggested as examples of young stars with circumstellar disks. 17 references

  19. An Application of a Pneumatic Muscles Actuator for a Delta Pneumatic Manipulator

    Directory of Open Access Journals (Sweden)

    Pawel A. LASKI

    2014-12-01

    Full Text Available The main aim of this study was to use pneumatic muscle actuators in the construction of the delta manipulator with a closed kinematic chain. The paper presents a solid models of the manipulator and the kinematic diagram. Based on the kinematic diagram and using DH notation (Denavit-Hartenberg manipulator kinematic models was determined. On the basis of developed solid model simulation studies were conducted and the shape and size of the workspace determined. On the basis of 3D models prototype of the manipulator was constructed. Experimental studies were performed to select the regulators settings P, PI, PID for one of the pair of BMDS (Bi-Muscular Driving System muscle-type drives. Based on integral quality indicators the used types of regulators were compared and proposed final controller. Performed experimental studies confirm the possibility of muscle control in the BMDS (Bi-Muscular Driving System type system drives and tuning controller settings using the Ziegler-Nichols method.

  20. Experimental induction of malignant catarrhal fever in pigs with ovine herpesvirus 2 by intranasal nebulization.

    Science.gov (United States)

    Li, Hong; Brooking, Angela; Cunha, Cristina W; Highland, Margaret A; O'Toole, Donal; Knowles, Donald P; Taus, Naomi S

    2012-10-12

    Malignant catarrhal fever (MCF), a frequently fatal herpesviral disease primarily of ruminant species, has been sporadically reported in pigs. All cases of naturally occurring porcine MCF reported to date have been linked to ovine herpesvirus 2 (OvHV-2), a gammaherpesvirus in the genus Macavirus carried by sheep. Experimental induction of MCF by aerosolization of the virus in nasal secretions collected from infected sheep has been successful in bison, cattle and rabbits. The goals of this study were to determine the susceptibility of pigs to MCF following experimental intranasal inoculation of OvHV-2, and to characterize the disease. Twelve pigs in four groups were nebulized with 10(5), 10(6), 10(7), or 10(8) DNA copies of OvHV-2 from sheep nasal secretions. Three control pigs were nebulized with nasal secretions from uninfected sheep. Three additional pigs were inoculated intravenously with 10(7) DNA copies of OvHV-2 to evaluate this route of infection with cell-free virus. Seven of twelve intranasally challenged pigs became infected with OvHV-2. Five of these seven, all in higher dose groups, developed MCF. Lesions resembled those reported in natural cases of porcine MCF. The most striking and consistent histological lesions were in trachea, lung, kidney and brain. These comprised mucopurulent tracheitis, interstitial pneumonia, necrotizing arteritis-periarteritis, and nonpurulent meningoencephalitis. No infection was established in the intravenously challenged or control groups. The study showed that MCF can be experimentally induced in pigs by aerosol challenge using sheep nasal secretions containing OvHV-2. Domestic pigs are a natural clinically susceptible host for sheep-associated MCF. They represent a useful, cost-effective model for MCF research. Published by Elsevier B.V.

  1. Design and Dynamic Model of a Frog-inspired Swimming Robot Powered by Pneumatic Muscles

    Science.gov (United States)

    Fan, Ji-Zhuang; Zhang, Wei; Kong, Peng-Cheng; Cai, He-Gao; Liu, Gang-Feng

    2017-09-01

    Pneumatic muscles with similar characteristics to biological muscles have been widely used in robots, and thus are promising drivers for frog inspired robots. However, the application and nonlinearity of the pneumatic system limit the advance. On the basis of the swimming mechanism of the frog, a frog-inspired robot based on pneumatic muscles is developed. To realize the independent tasks by the robot, a pneumatic system with internal chambers, micro air pump, and valves is implemented. The micro pump is used to maintain the pressure difference between the source and exhaust chambers. The pneumatic muscles are controlled by high-speed switch valves which can reduce the robot cost, volume, and mass. A dynamic model of the pneumatic system is established for the simulation to estimate the system, including the chamber, muscle, and pneumatic circuit models. The robot design is verified by the robot swimming experiments and the dynamic model is verified through the experiments and simulations of the pneumatic system. The simulation results are compared to analyze the functions of the source pressure, internal volume of the muscle, and circuit flow rate which is proved the main factor that limits the response of muscle pressure. The proposed research provides the application of the pneumatic muscles in the frog inspired robot and the pneumatic model to study muscle controller.

  2. Simulation of biomass pneumatic drying with ascending swirling movement

    International Nuclear Information System (INIS)

    Bombino Matos, Eugenio F.; Pineda Revilla, Edel

    2017-01-01

    Considering the layer form acquired by the particles during the studying process it was necessary to define the relation cheap between the heat and mass transfer area and particles flow to simulate with more precision this kind of drying. The simulations results were compared, by a statistical analysis based in Statgraphics-Centurion V15 program, with the results obtained in others pneumatic bagasse dryers studies and were similar and for that reason it was categorical that is correct the definition made about the relation cheap area/material flow defined in this work and it’s possible to reduce pneumatic dryer height by using this method. This reduction that can be seen by the Height Reduction Sing (HRS) of the drying column, defined in the work, will permit more compact dryers. (author)

  3. Performance characterization of pneumatic single pellet injection system

    International Nuclear Information System (INIS)

    Schuresko, D.D.; Milora, S.L.; Hogan, J.T.; Foster, C.A.; Combs, S.K.

    1983-01-01

    The Oak Ridge National Laboratory single-shot pellet injector, which has been used in plasma fueling experiments on ISX and PDX, has been upgraded and extensively instrumented in order to study the gas dyamics of pneumatic pellet injection. An improved pellet transport line was developed which utilizes a 0.3-cm-diam by 100-cm-long guide tube. Pellet gun performance was characterized by measurements of breech and muzzle dynamic pressures and by pellet velocity and mass determinations. Velocities of up to 1.4 km/s were achieved for intact hydrogen pellets using hydrogen propellant at 5-MPa breech pressure. These data have been compared with new pellet acceleration calculations which include the effects of propellant friction, heat transfer, time-dependent boundary conditions, and finite gun geometry. These results provide a basis for the extrapolation of present-day pneumatic injection system performance to velocities in excess of 2 km/s

  4. The Influence of Shaping Air Pressure of Pneumatic Spray Gun

    Science.gov (United States)

    Chen, Wenzhuo; Chen, Yan; Pan, Haiwei; Zhang, Weiming; Li, Bo

    2018-02-01

    The shaping air pressure is a very important parameter in the application of pneumatic spray gun, and studying its influence on spray flow field and film thickness distribution has practical values. In this paper, Euler-Lagrangian method is adopted to describe the two-phase spray flow of pneumatic painting process, and the air flow fields, spray patterns and dynamic film thickness distributions were obtained with the help of the computational fluid dynamics code—ANSYS Fluent. Results show that with the increase of the shaping air pressure, the air phase flow field spreads in the plane perpendicular to the shaping air hole plane, the spray pattern becomes narrower and flatter, and the width of the dynamic film increases with the reduced maximum value of the film thickness. But the film thickness distribution seems to change little with the shaping air pressure decreasing from 0.6bar to 0.9bar.

  5. Liquid-metal dip seal with pneumatic spring

    International Nuclear Information System (INIS)

    Poindexter, A.M.

    1977-01-01

    An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal

  6. Performance characterization of pneumatic single pellet injection system

    International Nuclear Information System (INIS)

    Schuresko, D.D.; Milora, S.L.; Hogan, J.T.; Foster, C.A.; Combs, S.K.

    1982-01-01

    The Oak Ridge National Laboratory single-shot pellet injector, which has been used in plasma fueling experiments on ISX and PDX, has been upgraded and extensively instrumented in order to study the gas dynamics of pneumatic pellet injection. An improved pellet transport line was developed which utilizes a 0.3-cm-diam by 100-cm-long guide tube. Pellet gun performance was characterized by measurements of breech and muzzle dynamic pressures and by pellet velocity and mass determinations. Velocities up to 1.4 km/s were achieved for intact hydrogen pellets using hydrogen propellant at 5-MPa breech pressure. These data have been compared with new pellet acceleration calculations which include the effects of propellant friction, heat transfer, time-dependent boundary conditions, and finite gun geometry. These results provide a basis for the extrapolation of present-day pneumatic injection system performance to velocities in excess of 2 km/s

  7. Research of pneumatic control transmission system for small irradiation samples

    International Nuclear Information System (INIS)

    Bai Zhongxiong; Zhang Haibing; Rong Ru; Zhang Tao

    2008-01-01

    In order to reduce the absorbed dose damage for the operator, pneumatic control has been adopted to realize the rapid transmission of small irradiation samples. On/off of pneumatic circuit and directions for the rapid transmission system are controlled by the electrical control part. The main program initializes the system and detects the location of the manual/automatic change-over switch, and call for the corresponding subprogram to achieve the automatic or manual operation. Automatic subprogram achieves the automatic sample transmission; Manual subprogram completes the deflation, and back and forth movement of the radiation samples. This paper introduces in detail the implementation of the system, in terms of both hardware and software design. (authors)

  8. Dielectric elastomer actuators used for pneumatic valve technology

    International Nuclear Information System (INIS)

    Giousouf, Metin; Kovacs, Gabor

    2013-01-01

    Dielectric elastomer actuators have been investigated for applications in the field of pneumatic automation technology. We have developed different valve designs with stacked dielectric elastomer actuators and with integrated high voltage converters. The actuators were made using VHB-4910 material and a stacker machine for automated fabrication of the cylindrical actuators. Typical characteristics of pneumatic valves such as flow rate, power consumption and dynamic behaviour are presented. For valve construction the force and stroke parameters of the dielectric elastomer actuator have been measured. Further, benefits for valve applications using dielectric elastomers are shown as well as their potential operational area. Finally, challenges are discussed that are relevant for the use of elastomer actuators in valves for industrial applications. (paper)

  9. Microcomputer-based pneumatic controller for neutron activation analysis

    International Nuclear Information System (INIS)

    Byrd, J.S.; Sand, R.J.

    1976-10-01

    A microcomputer-based pneumatic controller for neutron activation analysis was designed and built at the Savannah River Laboratory for analysis of large numbers of geologic samples for locating potential supplies of uranium ore for the National Uranium Resource Evaluation program. In this system, commercially available microcomputer logic modules are used to transport sample capsules through a network of pressurized air lines. The logic modules are interfaced to pneumatic valves, solenoids, and photo-optical detectors. The system operates from programs stored in firmware (permanent software). It also commands a minicomputer and a hard-wired pulse height analyzer for data collection and bookkeeping tasks. The advantage of the system is that major system changes can be implemented in the firmware with no hardware changes. This report describes the hardware, firmware, and software for the electronics system

  10. Pneumatic dilatation in achalasia cardia results and follow-up.

    Directory of Open Access Journals (Sweden)

    Supe A

    1990-10-01

    Full Text Available Pneumatic dilatation is one of the more recent methods in the management of achalasia cardia. Fifty dilatations were done in 42 patients with achalasia cardia over 5 years. There was a significant decrease in the maximum diameter of the oesophagus and a significant increase in diameter in the narrowed lower oesophageal segment in all the patients. Of the patients studied, 95.23% were relieved of their symptoms after only one to two sessions. There were no immediate complications. Out of the 38 patients on long term follow up, 8 (21.05% had recurrence of symptoms. On repeat dilatations, 4 (50% of them had good response. Late complication like reflux oesophagitis was observed in only 1 patient over a median follow up period of 22 months. It was thus concluded that pneumatic dilatation is a safe, simple and effective procedure in managing patients with achalasia cardia.

  11. Pneumatic Muscle Actuated Rehabilitation Equipment of the Upper Limb Joints

    Science.gov (United States)

    Deaconescu dr. eng. habil., Andrea, Prof.

    2017-06-01

    Rehabilitation equipment of the upper limb joints holds a key role in passive physical therapy. Within this framework, the paper presents two such pieces of equipment developed for the rehabilitation of elbow and of wrist and knuckles, respectively. The presented and discussed equipment is actuated by pneumatic muscles, its benefits being a low cost, simple and robust construction, as well as short response time to commands.

  12. Measurement of Static Characteristics Pneumatic Motors with Elastic Working Elements

    Directory of Open Access Journals (Sweden)

    Kamil FOJTÁŠEK

    2012-06-01

    Full Text Available Into a category of pneumatic motors with elastic working parts belong air bellows, diaphragm motors and fluid muscles. All three types of these motors have some elastic part usually made of rubber. This part is deformed under the pressure of a compressed air or a mass load resulting in a final working effect. This paper deals with measuring of static characteristics of these motors.

  13. Dynamic Analysis of Sounding Rocket Pneumatic System Revision

    Science.gov (United States)

    Armen, Jerald

    2010-01-01

    The recent fusion of decades of advancements in mathematical models, numerical algorithms and curve fitting techniques marked the beginning of a new era in the science of simulation. It is becoming indispensable to the study of rockets and aerospace analysis. In pneumatic system, which is the main focus of this paper, particular emphasis will be placed on the efforts of compressible flow in Attitude Control System of sounding rocket.

  14. Quantification of dynamic property of pneumatic muscle actuator for design of therapeutic robot control.

    Science.gov (United States)

    Balasubramanian, Sivakumar; Huang, He; He, Jiping

    2006-01-01

    Robot-assisted therapy has shown potential in neuromotor rehabilitation. A therapeutic robot driven by pneumatic muscle actuators has been developed in our research group. However, the design of fine and real-time feedback robot control is a challenge. One of the difficulties is the lack of a general dynamic model of the pneumatic muscle actuator. In this study, a phenomenological model has been developed to quantify the dynamic behavior of pneumatic muscle actuator by fitting the experimental length response of the pneumatic muscle, to a step pressure input. In addition, comparison of the dynamic responses of two pneumatic muscles of different dimensions has also been studied. Several control strategies for the pneumatic muscle actuator are discussed based on the results from this study.

  15. A study on the design of a low-friction, high-speed pneumatic cylinder

    International Nuclear Information System (INIS)

    Kim, Do Tae; Kim, Dong Soo; Ju, Min Jin

    2008-01-01

    Of all of pneumatic components utilized in the make up of pneumatic circuits on either automatic assembly machine or industrial equipment, the pneumatic cylinder is more oriented toward being a structural as well as a pneumatic member. The structural design must be based to a large degree on the end of application of the cylinder on the equipment it is operating. In this paper, design studies of a double-acting pneumatic cushion type cylinder with low-friction and high-speed driving have been developed. Of interest here is to investigate the structural analysis of cylinder tube, piston rod, end cover, and to analyze the buckling of piston rod. Also, a relief valve type cushion mechanism is considered. This cushion mechanism is found to be adequate under a high-speed driving of pneumatic cylinders

  16. Electric-Pneumatic Actuator: A New Muscle for Locomotion

    Directory of Open Access Journals (Sweden)

    Maziar Ahmad Sharbafi

    2017-10-01

    Full Text Available A better understanding of how actuator design supports locomotor function may help develop novel and more functional powered assistive devices or robotic legged systems. Legged robots comprise passive parts (e.g., segments, joints and connections which are moved in a coordinated manner by actuators. In this study, we propose a novel concept of a hybrid electric-pneumatic actuator (EPA as an enhanced variable impedance actuator (VIA. EPA is consisted of a pneumatic artificial muscle (PAM and an electric motor (EM. In contrast to other VIAs, the pneumatic artificial muscle (PAM within the EPA provides not only adaptable compliance, but also an additional powerful actuator with muscle-like properties, which can be arranged in different combinations (e.g., in series or parallel to the EM. The novel hybrid actuator shares the advantages of both integrated actuator types combining precise control of EM with compliant energy storage of PAM, which are required for efficient and adjustable locomotion. Experimental and simulation results based on the new dynamic model of PAM support the hypothesis that combination of the two actuators can improve efficiency (energy and peak power and performance, while does not increase control complexity and weight, considerably. Finally, the experiments on EPA adapted bipedal robot (knee joint of the BioBiped3 robot show improved efficiency of the actuator at different frequencies.

  17. Design and control of a pneumatic musculoskeletal biped robot.

    Science.gov (United States)

    Zang, Xizhe; Liu, Yixiang; Liu, Xinyu; Zhao, Jie

    2016-04-29

    Pneumatic artificial muscles are quite promising actuators for humanoid robots owing to their similar characteristics with human muscles. Moreover, biologically inspired musculoskeletal systems are particularly important for humanoid robots to perform versatile dynamic tasks. This study aims to develop a pneumatic musculoskeletal biped robot, and its controller, to realize human-like walking. According to the simplified musculoskeletal structure of human lower limbs, each leg of the biped robot is driven by nine muscles, including three pairs of monoarticular muscles which are arranged in the flexor-extensor form, as well as three biarticular muscles which span two joints. To lower cost, high-speed on/off solenoid valves rather than proportional valves are used to control the muscles. The joint trajectory tracking controller based on PID control method is designed to achieve the desired motion. Considering the complex characteristics of pneumatic artificial muscles, the control model is obtained through parameter identification experiments. Preliminary experimental results demonstrate that the biped robot is able to walk with this control strategy. The proposed musculoskeletal structure and control strategy are effective for the biped robot to achieve human-like walking.

  18. Soft Pneumatic Bending Actuator with Integrated Carbon Nanotube Displacement Sensor

    Directory of Open Access Journals (Sweden)

    Tim Giffney

    2016-02-01

    Full Text Available The excellent compliance and large range of motion of soft actuators controlled by fluid pressure has lead to strong interest in applying devices of this type for biomimetic and human-robot interaction applications. However, in contrast to soft actuators fabricated from stretchable silicone materials, conventional technologies for position sensing are typically rigid or bulky and are not ideal for integration into soft robotic devices. Therefore, in order to facilitate the use of soft pneumatic actuators in applications where position sensing or closed loop control is required, a soft pneumatic bending actuator with an integrated carbon nanotube position sensor has been developed. The integrated carbon nanotube position sensor presented in this work is flexible and well suited to measuring the large displacements frequently encountered in soft robotics. The sensor is produced by a simple soft lithography process during the fabrication of the soft pneumatic actuator, with a greater than 30% resistance change between the relaxed state and the maximum displacement position. It is anticipated that integrated resistive position sensors using a similar design will be useful in a wide range of soft robotic systems.

  19. Design and Control of a Pneumatically Actuated Transtibial Prosthesis.

    Science.gov (United States)

    Zheng, Hao; Shen, Xiangrong

    2015-04-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors' design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user.

  20. Homogeneity of blended nuclear fuel powders after pneumatic transport

    International Nuclear Information System (INIS)

    Smeltzer, E.E.; Skriba, M.C.; Lyon, W.L.

    1982-01-01

    A study of the pneumatic transport of fine (approx. 1μm) cohesive nuclear fuel powders was conducted for the U.S. Department of Energy to demonstrate the feasibility of this method of transport and to develop a design data base for use in a large scale nuclear fuel production facility. As part of this program, a considerable effort was directed at following the homogeneity of blended powders. Since different reactors require different enrichments, blending and subsequent transport are critical parts of the fabrication sequence. The various materials used represented analogs of a wide range of powders and blends that could be expected in a commercial mixed oxide fabrication facility. All UO 2 powders used were depleted and a co-precipitated master mix of (U, Th)O 2 was made specifically for this program, using thorium as an analog for plutonium. In order to determine the effect of pneumatic transport on a blended powder, samples were taken from a feeder vessel before each test, and from a receiver vessel and a few line sections after each transfer test. The average difference between the before and after degree of non-homogeneity was < 1%, for the 21 tests considered. This shows that overall, the pneumatic transport of blended, fine nuclear fuel powders is possible, with only minor unblending occurring

  1. Force Control for a Pneumatic Cylinder Using Generalized Predictive Controller Approach

    OpenAIRE

    Mohd Faudzi, Ahmad ’Athif; Mustafa, Nu’man Din; Osman, Khairuddin

    2014-01-01

    Pneumatic cylinder is a well-known device because of its high power to weight ratio, easy use, and environmental safety. Pneumatic cylinder uses air as its power source and converts it to a possible movement such as linear and rotary movement. In order to control the pneumatic cylinder, controller algorithm is needed to control the on-off solenoid valve with encoder and pressure sensor as the feedback inputs. In this paper, generalized predictive controller (GPC) is proposed as the control st...

  2. Vibration and recoil control of pneumatic hammers. [by air flow pressure regulation

    Science.gov (United States)

    Constantinescu, I. N.; Darabont, A. V.

    1974-01-01

    Vibration sources are described for pneumatic hammers used in the mining industry (pick hammers), in boiler shops (riveting hammers), etc., bringing to light the fact that the principal vibration source is the variation in air pressure inside the cylinder. The present state of the art of vibration control of pneumatic hammers as it is practiced abroad, and the solutions adopted for this purpose, are discussed. A new type of pneumatic hammer with a low noise and vibration level is presented.

  3. Pneumatic artificial muscle and its application on driving variable trailing-edge camber wing

    Science.gov (United States)

    Yin, Weilong; Liu, Libo; Chen, Yijin; Liu, Yanju; Leng, Jinsong

    2010-04-01

    As a novel bionic actuator, pneumatic artificial muscle has high power to weight ratio. In this paper, the experimental setup to measure the static output force of pneumatic artificial muscle was designed and the relationship between the static output force and the air pressure was investigated. Experimental result shows the static output force of pneumatic artificial muscle decreases nonlinearly with increasing contraction ratio. A variable camber wing based on the pneumatic artificial muscle was developed and the variable camber wing model was manufactured to validate the variable camber concept. Wind tunnel tests were conducted in the low speed wind tunnel. Experimental result shows that the wing camber increases with increasing air pressure.

  4. Development of a pneumatic transfer system for HTGR recycle fuel particles

    International Nuclear Information System (INIS)

    Mack, J.E.; Johnson, D.R.

    1978-02-01

    In support of the High-Temperature Gas-Cooled Reactor (HTGR) Fuel Refabrication Development Program, an experimental pneumatic transfer system was constructed to determine the feasibility of pneumatically conveying pyrocarbon-coated fuel particles of Triso and Biso designs. Tests were conducted with these particles in each of their nonpyrophoric forms to determine pressure drops, particle velocities, and gas flow requirements during pneumatic transfer as well as to evaluate particle wear and breakage. Results indicated that the material can be pneumatically conveyed at low pressures without excessive damage to the particles or their coatings

  5. Radionuclide esophageal emptying study before and after pneumatic dilatation in achalasia

    Energy Technology Data Exchange (ETDEWEB)

    Ujiie, Hiroaki; Hongo, Michio; Lin, Yih-Fong; Satake, Kenzo; Asaki, Shigeru; Goto, Yoshio; Okuyama, Shinichi

    1987-11-01

    The therapeutic effect of pneumatic dilatation was evaluated quantitatively by radionuclide transit study in 11 achalasia patients. Before pneumatic dilatation, marked retention with more than 80 % of isotope in the esophagus at 15 minutes after ingestion was noted in all patients. Marked improvement in emptying was shown after pneumatic dilatation. Pneumatic dilatation is a safe and effective therapeutic aid for achalasia treatment, and radionuclide transit study is not only noninvasive and physiologic but also its procedure is easily performed. We conclude that radionuclide transit study is a good method to evaluate the result of the treatment quantitatively in achalasia patients.

  6. Application of Model Based Prognostics to Pneumatic Valves in a Cryogenic Propellant Loading Testbed

    Data.gov (United States)

    National Aeronautics and Space Administration — Pneumatic-actuated valves are critical components in many applications, including cryogenic propellant loading for space operations. For these components, failures...

  7. Utilization of pneumatic energy in industries and Nuclear Energy Unit - a brief review

    International Nuclear Information System (INIS)

    Muhd Noor Muhd Yunus

    1984-01-01

    The purpose of this paper is to evaluate the extent of utilisation of pneumatic energy in UTN, besides depicting the capabilities of pneumatics in various field, especially in nuclear industry. Thus, a few examples of the usage of this energy in industry and UTN are explained and listed briefly. Comparisons and advantages of the pneumatics with respect to other forms of energy also discussed briefly. It is hoped that this pneumatic technology will advanced in UTN and becoming one of the alternatives of offered apart from other form of energy like hyrdaulics and electricity. (author)

  8. DETERMINATION OF CHARACTERISTICS OF THROTTLING DEVICE FOR PNEUMATIC SPRING

    Directory of Open Access Journals (Sweden)

    O. H. Reidemeister

    2018-02-01

    Full Text Available Purpose. This paper focuses on determination of the dependence of the working medium flow on the capacity of the throttling device, its geometric features and the pressure difference in the pneumatic spring cylinder and in the auxiliary reservoir. Methodology. Calculation of the dependence of the working medium and pressure drop is performed in two ways: 1 by numerical simulation of a stationary gas flow through a throttling element; 2 its analytical calculation expression using empirical relationships (control calculation to evaluate the reliability of numerical simulation results. For the calculation, three models of throttling devices were chosen. Dependence of the flow rate of the working medium on the capacity of the throttling device and its geometric features was determined based on the approximation of the dependency graphs of the pressure drop against the mass flow rate of the working medium. Findings. We obtained graphical dependencies between the pressure drop and the mass flow rate of the working medium from the two calculation options. Based on the results of calculations performed with the help of a software package with visualization of the results, we calculated a proportionality coefficient that describes the dependence of the working medium flow on the throttling device capacity and its geometric features for each of the throttling elements considered, with three degrees of closure. The air flow values, obtained by numerical simulation, are greater than the flow rates obtained from semi-empirical formulas. At the same time, they are in good qualitative agreement, and the quantitative difference averages 25%, which can be regarded as confirmation of the reliability of the nu-merical model. Based on the calculation results, we plotted the proportionality coefficient graphs against the degree of closure of the throttling device. Originality. The work allows determining the degree of influence of the frictio-nal component on the

  9. Comparison of Initial Response of Nebulized Salbutamol and Adrenaline in Infants and young Children Admitted with Acute Bronchiolitis.

    Science.gov (United States)

    Adhikari, S; Thapa, P; Rao, K S; Bk, G

    2016-01-01

    Background Acute bronchiolitis is common cause of hospitalization in infants and young children. There are widespread variations in the diagnosis and management. Despite the use of bronchodilators for decades, there is lack of consensus for the benefit of one above another. Objective To compare initial response of nebulized adrenaline and salbutamol. Method Children aged two months to two years admitted with acute bronchiolitis in the department of Paediatrics of Manipal teaching hospital, Pokhara, Nepal, from 1st March 2014 to 28th February 2015 were enrolled. Patients fulfilling inclusion criteria received either adrenaline or salbutamol nebulization. Data were collected in a predesigned proforma. Respiratory distress assessment instrument (RDAI) scores were considered primary outcome measure and respiratory rate at 48 hours, duration of hospital stay, requirement of supplemental oxygen and intravenous fluid were considered secondary outcome measure. Result A total of 40 patients were enrolled in each study group. Mean RDAI scores at admission was in 9.75 with (CI- 9.01, 10.49) in adrenaline and 9.77 (CI- 9.05, 10.50) in salbutamol group. There was gradual decline in mean RDAI scores in both the groups over 48 hours to 4.15 (CI- 3.57,4.73) and 4.13 (CI- 3.69,4.56) in adrenaline and salbutamol group respectively. Hospital stay was 5.32 days in adrenaline and 5.68 days in salbutamol group. Patients nebulized with adrenaline required oxygen for 33.30 hours compared with 36.45 hours in salbutamol. Intravenous fluid duration was also less in adrenaline group compared to salbutamol group (33.15 vs 37.80 hours). Conclusion Patients of acute bronchiolitis nebulized with either salbutamol or adrenaline experienced similar decline in RDAI scores in the first 48 hours. Duration of supplementary oxygen and intravenous fluid was less in adrenaline group compared with salbutamol group.

  10. EFFECT OF NEBULIZED COLISTIN ON THE VENTILATOR CIRCUIT: A PROSPECTIVE PILOT CASE-CONTROL STUDY FROM A SINGLE CANCER CENTER

    Directory of Open Access Journals (Sweden)

    Iyad M Ghonimat

    2015-04-01

    Full Text Available Nebulized colistin (NC is used for the treatment of pneumonia due to multidrug-resistant Gram-negative bacteria. In this one-year case-control study, our objective was to evaluate the effect of NC on the ventilator circuit (VC components. The case group consisted of 25 mechanically-ventilated patients who received NC, while the control group was 25 mechanically-ventilated patients who did not receive NC. Respiratory therapists inspected the VC every 4 hrs and whenever a ventilator alarm was reported. The VC component was changed if the alarm did not subside after necessary measures were performed. Patients from both groups were treated at the adult ICU in King Hussein Cancer Center (KHCC. In the case group, 22(88% patients required changing at least one of the circuit components (flow sensor, exhalation membrane, or nebulizer kit. The median number of changes (range per patient of the flow sensor, exhalation membrane, and nebulizer kit were: 2(1-3, 2(1-6, and 1(1-2, respectively. Large amounts of white crystals, which resembled the colistin powder, were reported on the replaced VC components. The flow sensor was changed in 2 control patients, but white crystals were absent. Crystals obtained from one case subject were confirmed to be colistin by chromatographic mass spectroscopy. Further studies are needed to evaluate the effect of crystal formation on the efficacy of NC and clinical outcomes.

  11. Pneumatic hybridization of a diesel engine using compressed air storage for wind-diesel energy generation

    International Nuclear Information System (INIS)

    Basbous, Tammam; Younes, Rafic; Ilinca, Adrian; Perron, Jean

    2012-01-01

    In this paper, we are studying an innovative solution to reduce fuel consumption and production cost for electricity production by Diesel generators. The solution is particularly suitable for remote areas where the cost of energy is very high not only because of inherent cost of technology but also due to transportation costs. It has significant environmental benefits as the use of fossil fuels for electricity generation is a significant source of GHG (Greenhouse Gas) emissions. The use of hybrid systems that combine renewable sources, especially wind, and Diesel generators, reduces fuel consumption and operation cost and has environmental benefits. Adding a storage element to the hybrid system increases the penetration level of the renewable sources, that is the percentage of renewable energy in the overall production, and further improves fuel savings. In a previous work, we demonstrated that CAES (Compressed Air Energy Storage) has numerous advantages for hybrid wind-diesel systems due to its low cost, high power density and reliability. The pneumatic hybridization of the Diesel engine consists to introduce the CAES through the admission valve. We have proven that we can improve the combustion efficiency and therefore the fuel consumption by optimizing Air/Fuel ratio thanks to the CAES assistance. As a continuation of these previous analyses, we studied the effect of the intake pressure and temperature and the exhaust pressure on the thermodynamic cycle of the diesel engine and determined the values of these parameters that will optimize fuel consumption. -- Highlights: ► Fuel economy analysis of a simple pneumatic hybridization of the Diesel engine using stored compressed air. ► Thermodynamic analysis of the pneumatic hybridization of diesel engines for hybrid wind-diesel energy systems. ► Analysis of intake pressure and temperature of compressed air and exhaust pressure on pressure/temperature during Diesel thermodynamic cycle. ► Direct admission of

  12. Different Nebulized Budesonide Dosing Regimens in a Mouse Model of Chronic Asthma

    Directory of Open Access Journals (Sweden)

    Pınar Uysal

    2016-12-01

    Full Text Available Objective: The aim of this study was to compare the effectiveness of different inhaled steroid regimens on the lungs and their potential side effects on the bone tissues in chronic asthma model. Materials and Methods: Thirty-five specific pathogen-free BALB/c mice were divided into five groups. The mice in all of the study groups except the control group were sensitized with chicken egg albumin. After sensitization, the mice in group 2 were treated with saline modeling twice daily, the mice in group 3 were treated with 250 mcg of nebulized budesonide twice daily, the mice in group 4 were treated with 500 mcg of budesonide once daily, and the mice in group 5 were treated with 1000 mcg of budesonide every other day for the last 14 days of the challenge period. After challenge, the mice were sacrificed and lung and tibia samples were histologically examined. Results: Pulmonary parameters, including subepithelial smooth muscle thickness, goblet cell count, mast cell count and epithelial thickness, were the lowest in group 5 compared to other groups (p0.01. Conclusion: The beneficial effect on lung tissue was highest in the treatment group receiving budesonide every other day (group 5 and no further measureable side effects on bone mineralization were observed in this group compared with the other treatment groups. Every-other-day treatment application seems to be the most effective regimen in chronic asthma model.

  13. Quantitative analysis of lead in aqueous solutions by ultrasonic nebulizer assisted laser induced breakdown spectroscopy

    Science.gov (United States)

    Zhong, Shi-Lei; Lu, Yuan; Kong, Wei-Jin; Cheng, Kai; Zheng, Ronger

    2016-08-01

    In this study, an ultrasonic nebulizer unit was established to improve the quantitative analysis ability of laser-induced breakdown spectroscopy (LIBS) for liquid samples detection, using solutions of the heavy metal element Pb as an example. An analytical procedure was designed to guarantee the stability and repeatability of the LIBS signal. A series of experiments were carried out strictly according to the procedure. The experimental parameters were optimized based on studies of the pulse energy influence and temporal evolution of the emission features. The plasma temperature and electron density were calculated to confirm the LTE state of the plasma. Normalizing the intensities by background was demonstrated to be an appropriate method in this work. The linear range of this system for Pb analysis was confirmed over a concentration range of 0-4,150ppm by measuring 12 samples with different concentrations. The correlation coefficient of the fitted calibration curve was as high as 99.94% in the linear range, and the LOD of Pb was confirmed as 2.93ppm. Concentration prediction experiments were performed on a further six samples. The excellent quantitative ability of the system was demonstrated by comparison of the real and predicted concentrations of the samples. The lowest relative error was 0.043% and the highest was no more than 7.1%.

  14. Elemental speciation via high-performance liquid chromatography combined with inductively coupled plasma atomic emission spectroscopic detection: application of a direct injection nebulizer

    International Nuclear Information System (INIS)

    LaFreniere, K.E; Fassel, V.A.; Eckels, D.E.

    1987-01-01

    An evaluation is presented of a direct injection nebulizer (DIN) interfaced to a high-performance liquid chromatograph (HPLC) with inductively coupled plasma atomic emission spectroscopic (ICP-AES) detection for simultaneous multielement speciation. The limits of detection (LODs) obtained with the DIN interface in the HPLC mode were found to be comparable to those obtained by continuous-flow sample introduction into the ICP, or inferior by up to only a factor of 4. In addition, the DIN allowed for the direct injection into the ICP of a variety of common HPLC solvents (up to 100% methanol, acetonitrile, methyl isobutyl ketone, pyridine, and water). The HPLC-DIN-ICP-AES system was compared to other HPLC-atomic spectroscopic detection techniques and was found to offer substantial improvement over the alternative on-line, detection methods in terms of LODs. Representative applications of the HPLC-DIN-ICP-AES system to the elemental speciation of coal process streams, shale oil, solvent refined coal, and crude oil are presented

  15. Statistical model estimating the occurrence of otitis media from temporal bone pneumatization

    DEFF Research Database (Denmark)

    Homøe, P; Lynnerup, N; Rasmussen, N

    1994-01-01

    In order to investigate the relationship between the pneumatization of temporal bones and the occurrence of otitis media in Greenlandic Inuit, 36 Greenlandic Inuit were examined by radiography of the temporal bones. The pneumatized cell area was measured planimetrically. All subjects answered...

  16. Pneumatization of the Temporal Bones in a Greenlandic Inuit Anthropological Material

    DEFF Research Database (Denmark)

    Homøe, P; Lynnerup, N

    1991-01-01

    The degree of pneumatization of the temporal bones correlates with exposure during childhood and adolescence to infectious middle ear diseases (IMED), both acute and chronic. The pneumatized area as seen on cranial X-rays can be measured. This was applied to an anthropological material in order...

  17. Electric and pneumatic drives in an exact comparison; Elektrische und pneumatische Antriebe im exakten Vergleich

    Energy Technology Data Exchange (ETDEWEB)

    Volk, Roland [Festo AG und Co. KG, Esslingen (Germany)

    2013-04-01

    The question, whether a pneumatic drive is more energy efficient than an electric drive, is very difficult to answer straightaway. In the automation technology, the energy efficiency always depends on the respective industrial application. Only the direct comparison of an electric and pneumatic drive having the same dimension in different conceptual formulations clears up with prejudices.

  18. Efficient control of servo pneumatic actuator system utilizing by-pass ...

    Indian Academy of Sciences (India)

    The issue of energy saving nowadays is very crucial. Pneumatic systems, constituting an important segment of almost every industry, represent large energy consumers. Also, a significant problem with servo pneumatic actuators is achieving accuracy in positioning. The higher the positioning accuracy, the higher the ...

  19. Introducing PneuAct: Parametrically-Designed MRI-Compatible Pneumatic Stepper Actuator

    NARCIS (Netherlands)

    Sojoodi Farimani, F.; Misra, Sarthak

    2018-01-01

    Pneumatic stepper motors are one of the promising alternative actuation methods for motion control in environments where electromagnetic (EM) motors cannot be used. Due to the lack of commercial off-the-shelf products, researchers working on MR compatible robotics have to develop their own pneumatic

  20. Static Modeling for Commercial Braided Pneumatic Muscle Actuators

    Directory of Open Access Journals (Sweden)

    Jun Zhong

    2014-05-01

    Full Text Available An enhanced model is proposed to describe static property of commercial braided pneumatic muscle actuators by including several important influencing factors. Elasticity of elastomer tube is considered and Ogden strain energy function is employed to describe its strain energy density. During pressurized process, small deformation of fiber occurs and is calculated using force balancing principle. Frictional forces within muscles are studied, which consist of friction within braid and that between bladder and braid. Isobaric experiments are performed and results verify the validity of the model.

  1. Comparison of contractile and extensile pneumatic artificial muscles

    Science.gov (United States)

    Pillsbury, Thomas E.; Wereley, Norman M.; Guan, Qinghua

    2017-09-01

    Pneumatic artificial muscles (PAMs) are used in robotic and prosthetic applications due to their high power to weight ratio, controllable compliance, and simple design. Contractile PAMs are typically used in traditional hard robotics in place of heavy electric motors. As the field of soft robotics grows, extensile PAMs are beginning to have increased usage. This work experimentally tests, models, and compares contractile and extensile PAMs to demonstrate the advantages and disadvantages of each type of PAM and applications for which they are best suited.

  2. Investigating the grindability effect of loose material conveyed pneumatically

    Energy Technology Data Exchange (ETDEWEB)

    Bandrowski, J.; Fitka, H.; Krajzel, J.; Raczek, J.; Kaczmarzyk, G.

    1979-10-01

    Presents a mathematical analysis of the grindability effect during pneumatic conveying of coal, coke breeze and ash. Mathematical grindability models are shown. The dependence of the grindability effect of the transported material on the following factors is analyzed: diameter of the grains, speed of their flow, concentration of grains in the air within the conveying system and the conveying time. It is noted that the results of the analysis are identical with the results of investigations described in the literature. (7 refs.) (In Polish)

  3. Adaptive Tracking Control of an Electro-Pneumatic Clutch Actuator

    Directory of Open Access Journals (Sweden)

    Glenn-Ole Kaasa

    2003-10-01

    Full Text Available This paper deals with the application of a simple adaptive algorithm for robust tracking control of an electro-pneumatic clutch actuator with output feedback. We present a mathematical model of the strongly nonlinear system, and implement an adaptive algorithm, based on a parallel feedforward compensator (PFC to remove the relative-degree-1 restriction. We propose a practical method of constructing the PFC, and introduce a simple modification that removes an inherent restriction on bandwidth of the nonlinear system. We show that the adaptive algorithm deals well with nonlinearities, and we achieve tracking corresponding to a settling-time of 150 ms.

  4. Micro Tools with Pneumatic Actuators for Desktop Factories

    Directory of Open Access Journals (Sweden)

    Björn HOXHOLD

    2009-10-01

    Full Text Available This paper presents the design, the simulation and the fabrication process of two novel pneumatically driven auxiliary micro tools that can be used to improve and to speed up assembling processes in desktop factories. The described micro systems are designed to function as centrifugal feeders for small glass balls or active clamping devices with small external dimensions. They are able to deliver more than six balls per second on demand to a gripper and align and clamp single chips in a fixed position.

  5. Pneumatic rupture of the esophagus caused by carbonated drinks

    International Nuclear Information System (INIS)

    Meyerovitch, J.; Barzilay, Z.; Tel Aviv Univ.; Ben Ami, T.; Rozenman, J.; Tel Aviv Univ.

    1988-01-01

    Pneumatic rupture of the esophagus occurs when gas under pressure is accidentally delivered into the oral cavity. To the 4 cases previously described we add 2 pediatric patients and in both the source of the offending gas was a bottle of carbonated drink. The mild initial symptoms were followed in both by physical and radiographic findings suggesting pharyngoesophageal perforation. Early radiologic findings included free subcutaneous and mediastinal air, followed later by hydropneumothorax and mediastinal widening as well as leak of contrast material on gastrografin swallow. CT findings contributed to patient evaluation and management. (orig.)

  6. Flow Rate Analysis of 3/2 Directional Pneumatic Valve by Means Of Ansys Cfx Software

    Directory of Open Access Journals (Sweden)

    Slawomir BLASIAK

    2014-12-01

    Full Text Available The main purpose of this paper was to develop a selection method of the pneumatic connectors for directional 3/2 valve. The method was established to minimize resistance and loss of pressure in the valve with mounted pneumatic connections for the selected pipe diameters. Directional valve was modeled in 3D CAD software SolidWorks while 3D models of the air connections have been downloaded from the website of one of the leading suppliers of pneumatic. Based on developed solid model the simulation of compressed air flow in the software for computational fluid dynamics Ansys CFX was conducted. The studies using CFD methods helped to determine which air connections best meet the assumptions. Performed numerical tests enable proper selection of items to the newly designed pneumatic systems for a particular group of valves. As a consequence, this translates into a reduction in energy consumption and improve the efficiency of the entire pneumatic complex system.

  7. Frictional properties of lubrication greases with the addition of nickel nanoparticles in pneumatic cylinder

    Science.gov (United States)

    Chang, Ho; Lan, Chou-Wei; Guo, Jia-Bin

    2011-12-01

    This paper studies the influence of addition of 100 nm diameter nickel nano-particles on the friction properties of synthetic grease (Li base, VG100) in pneumatic cylinder. The friction force test of pneumatic cylinder equipment measures the frictional force between seal and cylinder bore in pneumatic cylinders. The lubricants with addition of nickel nano-particles were used for lubricating the contact interface between seal and cylinder bore. The friction force test equipment employ a load cell force sensor to measure the friction force between seals and cylinder bores. Results obtained from experimental tests are compared to determine the friction force between seals and cylinder bore in pneumatic cylinders. The study leads to the conclusion that the addition of nickel nano-particles to synthetic grease results in a decrease in friction force between seals and cylinder bores in pneumatic cylinder. This tribological behavior is closely related to the deposition of nano-particles on the rubbing surfaces

  8. Pneumatic dilation and botulinum toxin: when and why?

    Science.gov (United States)

    Bozzi, Rosamaria; Di Martino, Vincenzo; Inzirillo, Antonio; D'Avenia, Eugenio; Inzirillo, Maurizio; Cattaneo, Fabio; Cattaneo, Domenico

    2013-01-01

    Pneumatic dilation and botulinum toxin:when and why? The endoscopic treatment options of achalasia include botulinum toxin (BT) injection and pneumatic dilation (PD) of the lower esophageal sphincter (LES). BT can reduce the LES pressure by blocking the release of acetylcoline from presynaptic cholinergic nerve terminals in the myenteric plexus. Although the procedure is safe and good initial response is reported, there is a wide variability in the duration of the response and the effect tends to decrease over time. BT is usually recommended for elderly patients or patients with comorbid illnesses, who are poor candidates for more invasive procedures. PD aims at tearing the muscle fibers of the LES and is considered the most effective nonsurgical treatment for achalasia. Technical details of the procedure vary in different institutions and in many clinical settings the choice between PD or minimally invasive surgical myotomy depends upon local expertise in the procedures. Further endoscopic treatment options such as submucosal esophageal myotomy or self-expanding metallic stents are being studied.

  9. Empirical modeling of dynamic behaviors of pneumatic artificial muscle actuators.

    Science.gov (United States)

    Wickramatunge, Kanchana Crishan; Leephakpreeda, Thananchai

    2013-11-01

    Pneumatic Artificial Muscle (PAM) actuators yield muscle-like mechanical actuation with high force to weight ratio, soft and flexible structure, and adaptable compliance for rehabilitation and prosthetic appliances to the disabled as well as humanoid robots or machines. The present study is to develop empirical models of the PAM actuators, that is, a PAM coupled with pneumatic control valves, in order to describe their dynamic behaviors for practical control design and usage. Empirical modeling is an efficient approach to computer-based modeling with observations of real behaviors. Different characteristics of dynamic behaviors of each PAM actuator are due not only to the structures of the PAM actuators themselves, but also to the variations of their material properties in manufacturing processes. To overcome the difficulties, the proposed empirical models are experimentally derived from real physical behaviors of the PAM actuators, which are being implemented. In case studies, the simulated results with good agreement to experimental results, show that the proposed methodology can be applied to describe the dynamic behaviors of the real PAM actuators. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Development of an Air Pneumatic Suspension System for Transtibial Prostheses

    Directory of Open Access Journals (Sweden)

    Gholamhossein Pirouzi

    2014-09-01

    Full Text Available The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded.

  11. MarsVac: Pneumatic Sampling System for Planetary Exploration

    Science.gov (United States)

    Zacny, K.; Mungas, G.; Chu, P.; Craft, J.; Davis, K.

    2008-12-01

    We are proposing a Mars Sample Return scheme whereby a sample of regolith is acquired directly into a Mars Ascent Vehicle using a pneumatic system. Unlike prior developments that used suction to collect fines, the proposed system uses positive pressure to move the regolith. We envisage 3 pneumatic tubes to be embedded inside the 3 legs of the lander. Upon landing, the legs will burry themselves into the regolith and the tubes will fill up with regolith. With one puff of gas, the regolith can be lifted into a sampling chamber onboard of the Mars Ascent Vehicle. An additional chamber can be opened to acquire atmospheric gas and dust. The entire MSR will require 1) an actuator to open/close sampling chamber and 2) a valve to open gas cylinder. In the most recent study related to lunar excavation and funded under the NASA SBIR program we have shown that it is possible lift over 3000 grams of soil with only 1 gram of gas at 1atm. Tests conducted under Mars atmospheric pressure conditions (5 torr). In September of 2008, we will be performing tests at 1/6thg (Moon) and 1/3g (Mars) to determine mass lifting efficiencies in reduced gravities.

  12. Pneumatic oscillator circuits for timing and control of integrated microfluidics.

    Science.gov (United States)

    Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E

    2013-11-05

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices.

  13. Multi Objective Optimization Using Genetic Algorithm of a Pneumatic Connector

    Science.gov (United States)

    Salaam, HA; Taha, Zahari; Ya, TMYS Tuan

    2018-03-01

    The concept of sustainability was first introduced by Dr Harlem Brutland in the 1980’s promoting the need to preserve today’s natural environment for the sake of future generations. Based on this concept, John Elkington proposed an approach to measure sustainability known as Triple Bottom Line (TBL). There are three evaluation criteria’s involved in the TBL approach; namely economics, environmental integrity and social equity. In manufacturing industry the manufacturing costs measure the economic sustainability of a company in a long term. Environmental integrity is a measure of the impact of manufacturing activities on the environment. Social equity is complicated to evaluate; but when the focus is at the production floor level, the production operator health can be considered. In this paper, the TBL approach is applied in the manufacturing of a pneumatic nipple hose. The evaluation criteria used are manufacturing costs, environmental impact, ergonomics impact and also energy used for manufacturing. This study involves multi objective optimization by using genetic algorithm of several possible alternatives for material used in the manufacturing of the pneumatic nipple.

  14. Pneumatic distension of ventricular mural architecture validated histologically

    Energy Technology Data Exchange (ETDEWEB)

    Burg, M.C.; Heindel, W. [University Hospital Muenster (Germany). Dept. of Clinical Radiology; Lunkenheimer, P. [University Hospital Muenster (Germany). Dept. of Experimental Thoraco-vascular Surgery; Niederer, P. [ETH and University of Zuerich (Switzerland). Inst. for Biomedical Engineering; Brune, C. [Twente Univ. (Netherlands). Dept. of Applied Mathematics; Redmann, K. [University Hospital Muenster (Germany). Center for Reproductive Medicine and Andrology; Smerup, M. [Aarhus University Hospital (Denmark). Dept. of Cardiothoracic and Vascular Surgery; Spiegel, U.; Becker, F. [University Hospital Muenster (Germany). Dept. Surgical Research; Maintz, D. [University Hospital Muenster (Germany). Dept. of Clinical Radiology; Cologne Univ. (Germany). Dept. of Radiology; Anderson, R.H. [Newcastle Univ., London (United Kingdom). Inst. of Genetic Medicine

    2016-11-15

    There are ongoing arguments as to how cardiomyocytes are aggregated together within the ventricular walls. We used pneumatic distension through the coronary arteries to exaggerate the gaps between the aggregated cardiomyocytes, analyzing the pattern revealed using computed tomography, and validating our findings by histology. We distended 10 porcine hearts, arresting 4 in diastole by infusion of cardioplegic solutions, and 4 in systole by injection of barium chloride. Mural architecture was revealed by computed tomography, measuring also the angulations of the long chains of cardiomyocytes. We prepared the remaining 2 hearts for histology by perfusion with formaldehyde. Increasing pressures of pneumatic distension elongated the ventricular walls, but produced insignificant changes in mural thickness. The distension exaggerated the spaces between the aggregated cardiomyocytes, compartmenting the walls into epicardial, central, and endocardial regions, with a feathered arrangement of transitions between them. Marked variation was noted in the thicknesses of the parts in the different ventricular segments, with no visible anatomical boundaries between them. Measurements of angulations revealed intruding and extruding populations of cardiomyocytes that deviated from a surface-parallel alignment. Scrolling through the stacks of tomographic images revealed marked spiraling of the aggregated cardiomyocytes when traced from base to apex. Our findings call into question the current assumption that cardiomyocytes are uniformly aggregated together in a tangential fashion. There is marked heterogeneity in the architecture of the different ventricular segments, with the aggregated units never extending in a fully transmural fashion.

  15. Pneumatic distension of ventricular mural architecture validated histologically

    International Nuclear Information System (INIS)

    Burg, M.C.; Heindel, W.; Lunkenheimer, P.; Niederer, P.; Brune, C.; Redmann, K.; Smerup, M.; Spiegel, U.; Becker, F.; Maintz, D.; Cologne Univ.; Anderson, R.H.

    2016-01-01

    There are ongoing arguments as to how cardiomyocytes are aggregated together within the ventricular walls. We used pneumatic distension through the coronary arteries to exaggerate the gaps between the aggregated cardiomyocytes, analyzing the pattern revealed using computed tomography, and validating our findings by histology. We distended 10 porcine hearts, arresting 4 in diastole by infusion of cardioplegic solutions, and 4 in systole by injection of barium chloride. Mural architecture was revealed by computed tomography, measuring also the angulations of the long chains of cardiomyocytes. We prepared the remaining 2 hearts for histology by perfusion with formaldehyde. Increasing pressures of pneumatic distension elongated the ventricular walls, but produced insignificant changes in mural thickness. The distension exaggerated the spaces between the aggregated cardiomyocytes, compartmenting the walls into epicardial, central, and endocardial regions, with a feathered arrangement of transitions between them. Marked variation was noted in the thicknesses of the parts in the different ventricular segments, with no visible anatomical boundaries between them. Measurements of angulations revealed intruding and extruding populations of cardiomyocytes that deviated from a surface-parallel alignment. Scrolling through the stacks of tomographic images revealed marked spiraling of the aggregated cardiomyocytes when traced from base to apex. Our findings call into question the current assumption that cardiomyocytes are uniformly aggregated together in a tangential fashion. There is marked heterogeneity in the architecture of the different ventricular segments, with the aggregated units never extending in a fully transmural fashion.

  16. CFD simulation of aerosol delivery to a human lung via surface acoustic wave nebulization.

    Science.gov (United States)

    Yousefi, Morteza; Pourmehran, Oveis; Gorji-Bandpy, Mofid; Inthavong, Kiao; Yeo, Leslie; Tu, Jiyuan

    2017-12-01

    Administration of drug in the form of particles through inhalation is generally preferable in the treatment of respiratory disorders. Conventional inhalation therapy devices such as inhalers and nebulizers, nevertheless, suffer from low delivery efficiencies, wherein only a small fraction of the inhaled drug reaches the lower respiratory tract. This is primarily because these devices are not able to produce a sufficiently fine drug mist that has aerodynamic diameters on the order of a few microns. This study employs computational fluid dynamics to investigate the transport and deposition of the drug particles produced by a new aerosolization technique driven by surface acoustic waves (SAWs) into an in silico lung model geometrically reconstructed using computed tomography scanning. The particles generated by the SAW are released in different locations in a spacer chamber attached to a lung model extending from the mouth to the 6th generation of the lung bronchial tree. An Eulerian approach is used to solve the Navier-Stokes equations that govern the airflow within the respiratory tract, and a Lagrangian approach is adopted to track the particles, which are assumed to be spherical and inert. Due to the complexity of the lung geometry, the airflow patterns vary as it penetrates deeper into the lung. High inertia particles tend to deposit at locations where the geometry experiences a significant reduction in cross section. Our findings, nevertheless, show that the injection location can influence the delivery efficiency: Injection points close to the spacer centerline result in deeper penetration into the lung. Additionally, we found that the ratio of drug particles entering the right lung is significantly higher than the left lung, independent of the injection location. This is in good agreement with this fact that the most of airflow enters to the right lobes.

  17. Evaluation of the Effect of Nebulized N-Acetylcysteine on Respiratory Secretions in Mechanically Ventilated Patients: Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Seyed Masoom Masoompour

    2015-07-01

    Full Text Available Background: The purpose of our study was to evaluate an inexpensive and available method to reduce mucous impactions in mechanically ventilated patients. Methods: This randomized clinical trial was conducted on 40 mechanically ventilated patients aged 15-90 years. The patients were randomly allocated into two arms; 20 cases and 20 controls. The cases received N-acetylcysteine via their nebulizers, and the control group received normal saline three times a day for one day. We measured the density of respiratory secretion, plateau and peak airway pressures, and O2 saturation at baseline, 12 and 24 hours later. Results: Although the mean secretion density was significantly lower in the NAC group (F (1, 38=8.61, P=0.006, but a repeated measures ANOVA with a Greenhouse-Geisser correction determined that the effect of NAC on mean secretion density did not differ significantly between time points (F (1, 38=3.08, P=0.087. NAC increased O2 saturation significantly between time points (F (1.92, 73.1=4.6, P=0.014. The plateau airway pressures were relatively stable throughout the study in the normal saline and NAC groups (F (1.95, 37.1=0.67, P=0.513. The peak airway pressure did not change significantly during the study in the normal saline and NAC groups (F (1.52, 56.4=0.91, P=0.384. Conclusion: Considering the limitations of the study, nebulized NAC in mechanically ventilated patients was not effective more than normal saline nebulization in reducing the density of mucous plugs. The peak and plateau airway pressures were relatively stable throughout the study in both groups. Trial Registration Number: IRCT201104276312N1.

  18. Numerical investigation of influence on heat transfer characteristics to pneumatically conveyed dense phase flow by selecting models and boundary conditions

    Science.gov (United States)

    Zheng, Y.; Liu, Q.; Li, Y.

    2012-03-01

    Solids moving with a gas stream in a pipeline can be found in many industrial processes, such as power generation, chemical, pharmaceutical, food and commodity transfer processes. A mass flow rate of the solids is important characteristic that is often required to be measured (and controlled) to achieve efficient utilization of energy and raw materials in pneumatic conveying systems. The methods of measuring the mass flow rate of solids in a pneumatic pipeline can be divided into direct and indirect (inferential) measurements. A thermal solids' mass flow-meter, in principle, should ideally provide a direct measurement of solids flow rate, regardless of inhomogeneities in solids' distribution and environmental impacts. One key issue in developing a thermal solids' mass flow-meter is to characterize the heat transfer between the hot pipe wall and the gas-solids dense phase flow. The Eulerian continuum modeling with gas-solid two phases is the most common method for pneumatic transport. To model a gas-solid dense phase flow passing through a heated region, the gas phase is described as a continuous phase and the particles as the second phase. This study aims to describe the heat transfer characteristics between the hot wall and the gas-solids dense phase flow in pneumatic pipelines by modeling a turbulence gas-solid plug passing through the heated region which involves several actual and crucial issues: selections of interphase exchange coefficient, near-wall region functions and different wall surface temperatures. A sensitivity analysis was discussed to identify the influence on the heat transfer characteristics by selecting different interphase exchange coefficient models and different boundary conditions. Simulation results suggest that sensitivity analysis in the choice of models is very significant. The simulation results appear to show that a combination of choosing the Syamlal-O'Brien interphase exchange coefficient model and the standard k-ɛ model along with

  19. Humidity control of an incubator using the microcontroller-based active humidifier system employing an ultrasonic nebulizer.

    Science.gov (United States)

    Güler, I; Burunkaya, M

    2002-01-01

    Relative humidity levels of an incubator were measured and controlled. An ultrasonic nebulizer system as an active humidifier was used to humidify the incubator environment. An integrated circuit-type humidity sensor was used to measure the humidity level of the incubator environment. Measurement and control processes were achieved by a PIC microcontroller. The high-performance and high-speed PIC provided the flexibility of the system. The developed system can be used effectively for the intensive care of newborns and/or premature babies. Since the humidifier generates an aerosol in ambient conditions, it is possible to provide the high relative humidity level for therapeutic and diagnostic purposes in medicine.

  20. Cranial base morphology and temporal bone pneumatization in Asian Homo erectus.

    Science.gov (United States)

    Balzeau, Antoine; Grimaud-Hervé, Dominique

    2006-10-01

    The external morphological features of the temporal bone are used frequently to determine taxonomic affinities of fossils of the genus Homo. Temporal bone pneumatization has been widely studied in great apes and in early hominids. However, this feature is rarely examined in the later hominids, particularly in Asian Homo erectus. We provide a comparative morphological and quantitative analysis of Asian Homo erectus from the sites of Ngandong, Sambungmacan, and Zhoukoudian, and of Neandertals and anatomically modern Homo sapiens in order to discuss causes and modalities of temporal bone pneumatization during hominid evolution. The evolution of temporal bone pneumatization in the genus Homo is more complex than previously described. Indeed, the Zhoukoudian fossils have a unique pattern of temporal bone pneumatization, whereas Ngandong and Sambungmacan fossils, as well as the Neandertals, more closely resemble the modern human pattern. Moreover, these Chinese fossils are characterized by a wide midvault and a relatively narrow occipital bone. Our results support the point of view that cell development does not play an active role in determining cranial base morphology. Instead, pneumatization is related to available space and to temporal bone morphology, and its development is related to correlated morphology and the relative disposition of the bones and cerebral lobes. Because variation in pneumatization is extensive within the same species, the phyletic implications of pneumatization are limited in the taxa considered here.

  1. Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.

    Science.gov (United States)

    Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian

    2015-11-01

    A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved.

  2. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback.

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.

  3. An MRI-Guided Telesurgery System Using a Fabry-Perot Interferometry Force Sensor and a Pneumatic Haptic Device.

    Science.gov (United States)

    Su, Hao; Shang, Weijian; Li, Gang; Patel, Niravkumar; Fischer, Gregory S

    2017-08-01

    This paper presents a surgical master-slave teleoperation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. The slave robot consists of a piezoelectrically actuated 6-degree-of-freedom (DOF) robot for needle placement with an integrated fiber optic force sensor (1-DOF axial force measurement) using the Fabry-Perot interferometry (FPI) sensing principle; it is configured to operate inside the bore of the MRI scanner during imaging. By leveraging the advantages of pneumatic and piezoelectric actuation in force and position control respectively, we have designed a pneumatically actuated master robot (haptic device) with strain gauge based force sensing that is configured to operate the slave from within the scanner room during imaging. The slave robot follows the insertion motion of the haptic device while the haptic device displays the needle insertion force as measured by the FPI sensor. Image interference evaluation demonstrates that the telesurgery system presents a signal to noise ratio reduction of less than 17% and less than 1% geometric distortion during simultaneous robot motion and imaging. Teleoperated needle insertion and rotation experiments were performed to reach 10 targets in a soft tissue-mimicking phantom with 0.70 ± 0.35 mm Cartesian space error.

  4. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2014-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446

  5. The qualitative assessment of pneumatic actuators operation in terms of vibration criteria

    Science.gov (United States)

    Hetmanczyk, M. P.; Michalski, P.

    2015-11-01

    The work quality of pneumatic actuators can be assessed in terms of multiple criteria. In the case of complex systems with pneumatic actuators retained at end positions (with occurrence of piston impact in cylinder covers) the vibration criteria constitute the most reliable indicators. The paper presents an impact assessment on the operating condition of the rodless pneumatic cylinder regarding to selected vibrational symptoms. On the basis of performed analysis the authors had shown meaningful premises allowing an evaluation of the performance and tuning of end position damping piston movement with usage the most common diagnostic tools (portable vibration analyzers). The presented method is useful in tuning of parameters in industrial conditions.

  6. Nebulized fluticasone propionate, a viable alternative to systemic route in the management of childhood moderate asthma attack: A double-blind, double-dummy study.

    Science.gov (United States)

    Demirca, Beyza Poplata; Cagan, Hasret; Kiykim, Ayca; Arig, Ulku; Arpa, Medeni; Tulunay, Aysin; Ozen, Ahmet; Karakoc-Aydiner, Elif; Baris, Safa; Barlan, I B

    2015-09-01

    In this study, we compared the clinical and immunological efficacy of nebulized corticosteroid (CS) to systemic route during treatment of moderate asthma attack in children. In this randomized, placebo-controlled, double-blind, double-dummy, prospective study, 81 children aged 12 months to 16 years experiencing asthma attack randomized into two treatment groups to receive, either; nebulized fluticasone propionate (n = 39, 2000 mcg/day) or oral methylprednisolone (n = 41, 1 mg/kg/day). Pulmonary index scores (PIS) were assessed at admission and at 1st, 4th, 8th, 12th, 24th, 48th hours, as well as, on day 7 and peak expiratory flow (PEF) at baseline and at the 7th day. Daily symptom and medication scores were recorded for all subjects. Immunological studies included phytohemagglutinin induced peripheral blood mononuclear cells culture supernatant for cytokine responses and CD4(+) CD25(+) FOXP3(+) T regulatory cell (T reg) percentage at baseline and day 7. The changes in PIS and PEF were similar in both treatment groups, with a significant improvement in both values at the 7th day, when compared to baseline. In both groups, significant reductions in symptom and medication scores were observed during the treatment period with no significant difference between the groups. At day 7 of intervention, phytohemagglutinin induced IL-4 level was significantly decreased only in the nebulized group compared to baseline (p = 0.01). Evaluation of cytokine responses by means of fold increase (stimulated (S)/unstimulated (US) ratio) revealed a significant reduction in IL-4, IL-5 and IL-17 only in nebulized group (p = 0.01, 0.01, 0.02; respectively). The fold increase value of IL-5 was significantly lower at 7th day in nebulized group when compared to systemic one (p = 0.02). At 7th day, although in both treatment groups the percentage of T reg cells was suppressed, it remained significantly higher in the nebule one when compared to systemic route (p = 0.04). In the management of

  7. A novel dynamic cardiac simulator utilizing pneumatic artificial muscle.

    Science.gov (United States)

    Liu, Hao; Yan, Jie; Zhou, Yuanyuan; Li, Hongyi; Li, Changji

    2013-01-01

    With the development of methods and skills of minimally invasive surgeries, equipments for doctors' training and practicing are in high demands. Especially for the cardiovascular surgeries, operators are requested to be familiar with the surgical environment of a beating heart. In this paper, we present a new dynamic cardiac simulator utilizing pneumatic artificial muscle to realize heartbeat. It's an artificial left ventricular of which the inner chamber is made of thermoplastic elastomers (TPE) with an anatomical structure of the real human heart. It is covered by another layer of material forming the artificial muscle which actuates the systole and diastole uniformly and omnidirectionally as the cardiac muscle does. Preliminary experiments were conducted to evaluate the performance of the simulator. The results indicated that the pressure at the terminal of the aorta could be controlled within the range of normal human systolic pressure, which quantitatively validated the new actuating mode of the heart-beating is effective.

  8. Design of a biped robot actuated by pneumatic artificial muscles.

    Science.gov (United States)

    Liu, Yixiang; Zang, Xizhe; Liu, Xinyu; Wang, Lin

    2015-01-01

    High compliant legs are essential for the efficient versatile locomotion and shock absorbency of humans. This study proposes a biped robot actuated by pneumatic artificial muscles to mimic human locomotion. On the basis of the musculoskeletal architecture of human lower limbs, each leg of the biped robot is modeled as a system of three segments, namely, hip joint, knee joint, and ankle joint, and eleven muscles, including both monoarticular and biarticular muscles. Each rotational joint is driven by a pair of antagonistic muscles, enabling joint compliance to be tuned by operating the pressure inside the muscles. Biarticular muscles play an important role in transferring power between joints. Walking simulations verify that biarticular muscles contribute to joint compliance and can absorb impact energy when the robot makes an impact upon ground contact.

  9. Research on Dynamic Parameters and Position Accuracy of Pneumatics Muscles

    Directory of Open Access Journals (Sweden)

    Edvard Sadovskij

    2012-12-01

    Full Text Available The article deals with pneumatic muscle MAS-20-200N-AA-MC-O, its dynamic properties and positioning accuracy as well as overviews experimental and theoretical works. The paper introduces the diagrams of vibration acceleration, discusses displacement dependence on pressure and load and presents a diagram of speed dependence on operating pressure. Vibroacceleration has been measured employing two accelerometers. Measurements have been carried out in three mutually perpendicular directions: x, y and z. The most important one is direction z, because this way the muscle performs a valuable displacement along the axis of the muscle, since this direction is the movement of the working muscle.Article in Lithuanian

  10. Research on Dynamic Parameters and Position Accuracy of Pneumatics Muscles

    Directory of Open Access Journals (Sweden)

    Edvard Sadovskij

    2013-02-01

    Full Text Available The article deals with pneumatic muscle MAS-20-200N-AA-MC-O, its dynamic properties and positioning accuracy as well as overviews experimental and theoretical works. The paper introduces the diagrams of vibration acceleration, discusses displacement dependence on pressure and load and presents a diagram of speed dependence on operating pressure. Vibroacceleration has been measured employing two accelerometers. Measurements have been carried out in three mutually perpendicular directions: x, y and z. The most important one is direction z, because this way the muscle performs a valuable displacement along the axis of the muscle, since this direction is the movement of the working muscle.Article in Lithuanian

  11. Preliminary measurements on heat balance in pneumatic tires

    Science.gov (United States)

    Nybakken, G. H.; Collart, D. Y.; Staples, R. J.; Lackey, J. I.; Clark, S. K.; Dodge, R. N.

    1973-01-01

    A variety of tests was undertaken to determine the nature of heat generation associated with a pneumatic tire operating under various conditions. Tests were conducted to determine the magnitude and distribution of internally generated heat caused by hysteresis in the rubber and ply fabric in an automobile tire operating under conditions of load, pressure, and velocity representative of normal operating conditions. These included tests at various yaw angles and tests with braking applied. In other tests, temperature sensors were mounted on a road to measure the effect of a tire rolling over and an attempt was made to deduce the magnitude and nature of interfacial friction from the resulting information. In addition, tests were performed using the scratch plate technique to determine the nature of the motion between the tire and road. Finally, a model tire was tested on a roadwheel, the surface covering which could be changed, and an optical pyrometer was used to measure rubber surface temperatures.

  12. Endoscope-guided pneumatic dilation for treatment of esophageal achalasia

    Science.gov (United States)

    Chuah, Seng-Kee; Wu, Keng-Liang; Hu, Tsung-Hui; Tai, Wei-Chen; Changchien, Chi-Sin

    2010-01-01

    Pneumatic dilation (PD) is considered to be the first line nonsurgical therapy for achalasia. The principle of the procedure is to weaken the lower esophageal sphincter by tearing its muscle fibers by generating radial force. The endoscope-guided procedure is done without fluoroscopic control. Clinicians usually use a low-compliance balloon such as Rigiflex dilator to perform endoscope-guided PD for the treatment of esophageal achalasia. It has the advantage of determining mucosal injury during the dilation process, so that a repeat endoscopy is not needed to assess the mucosal tearing. Previous studies have shown that endoscope-guided PD is an efficient and safe nonsurgical therapy with results that compare well with other treatment modalities. Although the results may be promising, long-term follow-up is required in the near future. PMID:20101764

  13. Design of pneumatic proportional flow valve type 5/3

    Science.gov (United States)

    Laski, P. A.; Pietrala, D. S.; Zwierzchowski, J.; Czarnogorski, K.

    2017-08-01

    In this paper the 5/3-way pneumatic, proportional flow valve was designed and made. Stepper linear actuator was used to move the spool. The valve is controlled by the controlled based on a AVR microcontroller. Virtual model of the valve was created in CAD. The real element was made based on a standard 5/3-way manually actuated valve with hand lever, which was dismounted and replaced by linear stepper motor. All the elements was mounted in a specially made housing. The controller consists of microcontroller Atmega16, integrated circuit L293D, display, two potentiometers, three LEDs and six buttons. Series of research was also conducted. Simulation research were performed using CFD by the Flow Simulation addition to SolidWorks. During the experiments the valve characteristics of flow and pressure was determined.

  14. Functional design of heat exchange for pneumatic vehicles

    Science.gov (United States)

    Xu, Z. G.; Yang, D. Y.; Shen, W. D.; Liu, T. T.

    2017-10-01

    With the increasingly serious environmental problems, especially the impact of fog and haze, the development of air powered vehicles has become an important research direction of new energy vehicles. Quadrature test was done with different materials, i.e. stainless steel and aluminum alloy, at different inlet pressures, using different expansion gases, i.e. air, CO2, for heat exchanging properties for pneumatic vehicles. The mathematics as well as simulation methods are used to analyze the different heat exchanging effects in the multistage cylinder. The research results showed that the stainless steel has better effects in heat exchanging than Aluminum Alloy; the intake pressure has little effect on CO2 than the air in heat exchanging effect. CO2 is better in heat exchanging than air.

  15. Pneumatic injector of deuterium macroparticles for TORE-SUPRA tokamak

    International Nuclear Information System (INIS)

    Vinyar, I.V.; Umov, A.P.; Lukin, A.Ya.; Skoblikov, S.V.; Reznichenko, P.V.; Krasil'nikov, I.A.

    2006-01-01

    The pneumatic injector for periodic injection of fuel-solid-deuterium pellets into the plasma of the TORE-SUPRA tokamak in a steady-state mode is described. The deuterium pellet injection with an unlimited duration is ensured by a screw extruder in which gaseous deuterium is frozen and squeezed outwards in the form of a rod with a rectangular cross section. A cutter installed on the injector's barrel cuts a cylinder with a diameter of 2 mm and a length of 1.0-3.5 mm out from this rod. The movement of the cutter is controlled by a pulsed electromagnetic drive at a pulse repetition rate of 10 Hz. In the injector's barrel, a compressed gas accelerates a deuterium pellet to a velocity of 100-650 m/s [ru

  16. Evaluation of Effective Diaphragm Area for Pneumatic Actuator

    International Nuclear Information System (INIS)

    Ryu, Hogeun; Han, Bongsub; Seon, Juhyoung

    2016-01-01

    The purpose of this study is to develop a methodology to calculate the exact effective diaphragm area using the results of diagnostic test to be performed in the evaluation of air operated valve performance. By using this developed methodology in pneumatic actuator performance evaluation, it can be reduce the possible errors arising from effective diaphragm area in the evaluation of performance of air operated valves. The performance assessment for the operability and structural integrity of air operated valves for the domestic nuclear power plant is in progress. One of the important parameters that determine the performance of the air operated valves is the effective diaphragm area of diaphragm type actuator. The effective diaphragm area is the actual area which the air pressure acting on the diaphragm. In general, the effective diaphragm area used for the performance evaluation of pneumatic actuator is provided by the manufacture or the actuator drawing. Flat type diaphragm was showed the difference between the measured value of EDA and the manufacture’s value, in the case of convoluted type diaphragm has showed that the measured value of EDA and manufacture’s value is almost the same. When evaluate a performance of a diaphragm actuator, accurate EDA is to be used because it is an important variable affecting the actuator performance. Particularly in the case of flat type diaphragm which EDA is changed in accordance with the stroke position, by using the EDA evaluation methodology developed in this study to minimize a possible error due to EDA when evaluating the performance of the air actuator

  17. Analysis of nonlinear elastic behavior in miniature pneumatic artificial muscles

    Science.gov (United States)

    Hocking, Erica G.; Wereley, Norman M.

    2013-01-01

    Pneumatic artificial muscles (PAMs) are well known for their excellent actuator characteristics, including high specific work, specific power, and power density. Recent research has focused on miniaturizing this pneumatic actuator technology in order to develop PAMs for use in small-scale mechanical systems, such as those found in robotic or aerospace applications. The first step in implementing these miniature PAMs was to design and characterize the actuator. To that end, this study presents the manufacturing process, experimental characterization, and analytical modeling of PAMs with millimeter-scale diameters. A fabrication method was developed to consistently produce low-cost, high performance, miniature PAMs using commercially available materials. The quasi-static behavior of these PAMs was determined through experimentation on a single actuator with an active length of 39.16 mm (1.54 in) and a diameter of 4.13 mm (0.1625 in). Testing revealed the PAM’s full evolution of force with displacement for operating pressures ranging from 207 to 552 kPa (30-80 psi in 10 psi increments), as well as the blocked force and free contraction at each pressure. Three key nonlinear phenomena were observed: nonlinear PAM stiffness, hysteresis of the force versus displacement response for a given pressure, and a pressure deadband. To address the analysis of the nonlinear response of these miniature PAMs, a nonlinear stress versus strain model, a hysteresis model, and a pressure bias are introduced into a previously developed force balance analysis. Parameters of these nonlinear model refinements are identified from the measured force versus displacement data. This improved nonlinear force balance model is shown to capture the full actuation behavior of the miniature PAMs at each operating pressure and reconstruct miniature PAM response with much more accuracy than previously possible.

  18. Analysis of nonlinear elastic behavior in miniature pneumatic artificial muscles

    International Nuclear Information System (INIS)

    Hocking, Erica G; Wereley, Norman M

    2013-01-01

    Pneumatic artificial muscles (PAMs) are well known for their excellent actuator characteristics, including high specific work, specific power, and power density. Recent research has focused on miniaturizing this pneumatic actuator technology in order to develop PAMs for use in small-scale mechanical systems, such as those found in robotic or aerospace applications. The first step in implementing these miniature PAMs was to design and characterize the actuator. To that end, this study presents the manufacturing process, experimental characterization, and analytical modeling of PAMs with millimeter-scale diameters. A fabrication method was developed to consistently produce low-cost, high performance, miniature PAMs using commercially available materials. The quasi-static behavior of these PAMs was determined through experimentation on a single actuator with an active length of 39.16 mm (1.54 in) and a diameter of 4.13 mm (0.1625 in). Testing revealed the PAM’s full evolution of force with displacement for operating pressures ranging from 207 to 552 kPa (30–80 psi in 10 psi increments), as well as the blocked force and free contraction at each pressure. Three key nonlinear phenomena were observed: nonlinear PAM stiffness, hysteresis of the force versus displacement response for a given pressure, and a pressure deadband. To address the analysis of the nonlinear response of these miniature PAMs, a nonlinear stress versus strain model, a hysteresis model, and a pressure bias are introduced into a previously developed force balance analysis. Parameters of these nonlinear model refinements are identified from the measured force versus displacement data. This improved nonlinear force balance model is shown to capture the full actuation behavior of the miniature PAMs at each operating pressure and reconstruct miniature PAM response with much more accuracy than previously possible. (paper)

  19. Comparison of Pneumatic, Ultrasonic and Combination Lithotripters in Percutaneous Nephrolithotripsy

    Directory of Open Access Journals (Sweden)

    Kursad Zengin

    2014-10-01

    Full Text Available Purpose We aimed to compare the outcomes of pneumatic (PL, ultrasonic (UL and combined (PL/UL lithotripsy performed in percutaneous lithotripsy (PNL according to success rates and stone clearence. Materials and Methods The medical records of 512 patients treated with PNL between April 2010 and April 2013 were evaluated. Postoperative stone analysis revealed as calcium oxalate in 408 of these patients. The operation notes of 355 patients recorded in detail with complete parameters were reviewed. According to stone disintegration method, patients were divided into three groups: PL only in Group I, UL only in Group II, and UL/PL combination in Group III. Number of patients was 155, 110 and 90, respectively. Results Fluoroscopy screening time was significantly shorter in group II, and III compared to group I (p<0.001. The failure rates were 13.5% (21 patients for group I, 3.6% (4 patients for group II, and 3.3% (3 patients for group III. There was a significant statistical difference in favor of group II and III by means of success (p=0.023. Group II and III had larger FSA, and this was statistically significant (p=0.032. Stone disintegration time (SDT was 64.0±41.92 minutes for group I, 49.5±34.63 for group II, and 37.7±16.89 for group III. Group III has a statistically significant shorter SDT (p=0.011. Conclusions We concluded that, in cases with high stone burden, where faster and efficient lithotripsy is needed, combined ultrasonic / pneumatic lithotripter may be the ideal choice and in suitable cases ultrasonic lithotripter usage provides important advantages to the surgeon.

  20. A pneumatic transfer system for special form 252Cf

    International Nuclear Information System (INIS)

    Gehrke, R.J.; Berry, S.M.; Grafwallner, E.G.; Hoggan, J.M.

    1996-09-01

    A pneumatic transfer system has been developed for use with series 100 Special Form 252 Cf. It was developed to reduce the exposure to personnel handling sources of 252 Cf with masses up to 150 microg by permitting remotely activated two-way transfer between the storage container and the irradiation position. The pneumatic transfer system also permits transfers for reproducible repetitive irradiation periods. In addition to the storage container equipped with quick-release fittings, the transfer system consists of an irradiation station, a control box with momentary contact switches to activate the air-pressure control valves and indicators to identify the location of the source, and connecting air hose and electrical wire. A source of 20 psig air and 110 volt electrical power are required for operation of the transfer system which can be easily moved and set up by one individual in 5 to 10 minutes. Tests have shown that rarely does a source become lodged in the transfer tubing, but two methods have been developed to handle incomplete transfers of the 252 Cf source. The first method consists of closing one air vent to allow a pressure impulse to propel the source to the opposite side. The second method applies to those 252 Cf capsules with a threaded or tapped end to which a small ferromagnetic piece can be attached; an incompletely transferred source in the transfer tube can then be guided to a position of safety by surrounding the transfer tubing containing the capsule with a horseshoe magnet attached to the end of a long pole

  1. Validity and reliability of a controlled pneumatic resistance exercise device.

    Science.gov (United States)

    Paulus, David C; Reynolds, Michael C; Schilling, Brian K

    2008-01-01

    During the concentric portion of the free-weight squat exercise, accelerating the mass from rest results in a fluctuation in ground reaction force. It is characterized by an initial period of force greater than the load while accelerating from rest followed by a period of force lower than the external load during negative acceleration. During the deceleration phase, less force is exerted and muscles are loaded sub-optimally. Thus, using a reduced inertia form of resistance such as pneumatics has the capability to minimize these inertial effects as well as control the force in real time to maximize the force exerted over the exercise cycle. To improve the system response of a preliminary design, a squat device was designed with a reduced mass barbell and two smaller pneumatic cylinders. The resistance was controlled by regulating cylinder pressure such that it is capable of adjusting force within a repetition to maximize force exerted during the lift. The resistance force production of the machine was statically validated with the input voltage and output force R2 =0.9997 for at four increments of the range of motion, and the intraclass correlation coefficient (ICC) between trials at the different heights equaled 0.999. The slew rate at three forces was 749.3 N/s +/- 252.3. Dynamic human subject testing showed the desired input force correlated with average and peak ground reaction force with R2 = 0.9981 and R2 = 0.9315, respectively. The ICC between desired force and average and peak ground reaction force was 0.963. Thus, the system is able to deliver constant levels of static and dynamic force with validity and reliability. Future work will be required to develop the control strategy required for real-time control, and performance testing is required to determine its efficacy.

  2. Pneumatic strength assessment device: design and isometric measurement.

    Science.gov (United States)

    Paulus, David C; Reiser, Raoul F; Troxell, Wade O

    2004-01-01

    In order to load a muscle optimally during resistance exercise, it should be heavily taxed throughout the entire range of motion for that exercise. However, traditional constant resistance squats only tax the lower-extremity muscles to their limits at the "sticking region" or a critical joint configuration of the exercise cycle. Therefore, a linear motion (Smith) exercise machine was modified with pneumatics and appropriate computer control so that it could be capable of adjusting force to control velocity within a repetition of the squat exercise or other exercise performed with the device. Prior to application of this device in a dynamic squat setting, the maximum voluntary isometric force (MVIF) produced over a spectrum of knee angles is needed. This would reveal the sticking region and overall variation in strength capacity. Five incremental knee angles (90, 110, 130, 150, and 170 degrees, where 180 degrees defined full extension) were examined. After obtaining university-approved informed consent, 12 men and 12 women participated in the study. The knee angle was set, and the pneumatic cylinder was pressurized such that the subject could move the barbell slightly but no more than two-centimeters. The peak pressure exerted over a five-second maximum effort interval was recorded at each knee angle in random order and then repeated. The average of both efforts was then utilized for further analysis. The sticking region occurred consistently at a 90 degrees knee angle, however, the maximum force produced varied between 110 degrees and 170 degrees with the greatest frequency at 150 degrees for both men and women. The percent difference between the maximum and minimum MVIF was 46% for men and 57% for women.

  3. Characterization of graphite dust produced by pneumatic lift

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Ke [Guangdong Provincial Key Laboratory of Thermal Management Engineering and Materials, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong (China); Peng, Wei; Liu, Bing [Institute of Nuclear and New Energy Technology of Tsinghua University, Advanced Nuclear Energy Technology Cooperation Innovation Center, The Key Laboratory of Advanced Nuclear Engineering and Safety, Ministry of Education, Beijing 100084 (China); Kang, Feiyu [Guangdong Provincial Key Laboratory of Thermal Management Engineering and Materials, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong (China); Yang, Xiaoyong; Li, Weihua [Institute of Nuclear and New Energy Technology of Tsinghua University, Advanced Nuclear Energy Technology Cooperation Innovation Center, The Key Laboratory of Advanced Nuclear Engineering and Safety, Ministry of Education, Beijing 100084 (China); Yu, Suyuan, E-mail: suyuan@tsinghua.edu.cn [Center for Combustion Energy, The Key Laboratory for Thermal Science and Power Engineering, Ministry of Educations, Tsinghua University, Beijing 100084 (China)

    2016-08-15

    Highlights: • Generation of graphite dust by pneumatic lift. • Determination of morphology and particle size distribution of graphite dust. • The size of graphite dust in this study is compared to AVR and THTR-300 results. • Graphite dust originates from both filler and binder of the matrix graphite. - Abstract: Graphite dust is an important safety concern of high-temperature gas-cooled reactor (HTR). The graphite dust could adsorb fission products, and the radioactive dust is transported by the coolant gas and deposited on the surface of the primary loop. The simulation of coagulation, aggregation, deposition, and resuspension behavior of graphite dust requires parameters such as particle size distribution and particle shape, but currently very limited data on graphite dust is available. The only data we have are from AVR and THTR-300, however, the AVR result is likely to be prejudiced by the oil ingress. In pebble-bed HTR, graphite dust is generally produced by mechanical abrasion, in particular, by the abrasion of graphite pebbles in the lifting pipe of the fuel handling system. Here we demonstrate the generation and characterization of graphite dust that were produced by pneumatic lift. This graphite dust could substitute the real dust in HTR for characterization. The dust, exhibiting a lamellar morphology, showed a number-weighted average particle size of 2.38 μm and a volume-weighted average size of 14.62 μm. These two sizes were larger than the AVR and THTR results. The discrepancy is possibly due to the irradiation effect and prejudice caused by the oil ingress accident. It is also confirmed by the Raman spectrum that both the filler particle and binder contribute to the dust generation.

  4. Effective dose at pneumatic reduction of paediatric intussusception

    International Nuclear Information System (INIS)

    Heenan, S.D.; Kyriou, J.; Fitzgerald, M.; Adam, E.J.

    2000-01-01

    AIM: The purpose of this study was to assess screening times and resulting dose implication at pneumatic reduction of intussusception in the paediatric age group and to examine the relationship with the outcome of the procedure. MATERIALS AND METHODS: We retrospectively reviewed the case notes and departmental records of 143 children who had undergone a total of 153 pneumatic reductions in our department over a 4-year period. Success rates, screening times and available dose-area products (DAP) were recorded. The DAPs were converted to effective dose (ED) for 77 procedures. RESULTS: A 76.5% (117/153) success rate was achieved with a recurrence rate of 6.5% and only one complication: a perforation. Screening times were recorded in 137 reductions and ranged from 15 s to 22.6 min. Although the longest screening time was associated with an unsuccessful outcome, the second longest time of 21 min was successful. This gave a DAP of 1278 cGy cm 2 and an ED of 12.73 mSv, which is equivalent to approximately 400 abdominal films for a 1-year-old. A lifetime risk of fatal cancer of one in 1000 was achieved, assuming the worst case, after a screening time of 30 min on our conventional fluoroscopy unit. CONCLUSION: Our success rate compares well with other centres. Our institution is a tertiary referral centre and the occasional long screening time may reflect the delay and complex nature of the patients referred. Persistence at air reduction may be successful and the success rate increases with delayed attempts but the risks of the increasing radiation burden must be weighed against the risks of emergency surgery and anaesthesia. Heenan, S.D. (2000)

  5. Evaluation of Effective Diaphragm Area for Pneumatic Actuator

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Hogeun; Han, Bongsub; Seon, Juhyoung [SOOSAN INDUSTRIES, Seoul (Korea, Republic of)

    2016-10-15

    The purpose of this study is to develop a methodology to calculate the exact effective diaphragm area using the results of diagnostic test to be performed in the evaluation of air operated valve performance. By using this developed methodology in pneumatic actuator performance evaluation, it can be reduce the possible errors arising from effective diaphragm area in the evaluation of performance of air operated valves. The performance assessment for the operability and structural integrity of air operated valves for the domestic nuclear power plant is in progress. One of the important parameters that determine the performance of the air operated valves is the effective diaphragm area of diaphragm type actuator. The effective diaphragm area is the actual area which the air pressure acting on the diaphragm. In general, the effective diaphragm area used for the performance evaluation of pneumatic actuator is provided by the manufacture or the actuator drawing. Flat type diaphragm was showed the difference between the measured value of EDA and the manufacture’s value, in the case of convoluted type diaphragm has showed that the measured value of EDA and manufacture’s value is almost the same. When evaluate a performance of a diaphragm actuator, accurate EDA is to be used because it is an important variable affecting the actuator performance. Particularly in the case of flat type diaphragm which EDA is changed in accordance with the stroke position, by using the EDA evaluation methodology developed in this study to minimize a possible error due to EDA when evaluating the performance of the air actuator.

  6. Experimental human-like model to assess the part of viable Legionella reaching the thoracic region after nebulization.

    Directory of Open Access Journals (Sweden)

    Jérémie Pourchez

    Full Text Available The incidence of Legionnaires' disease (LD in European countries and the USA has been constantly increasing since 1998. Infection of humans occurs through aerosol inhalation. To bridge the existing gap between the concentration of Legionella in a water network and the deposition of bacteria within the thoracic region (assessment of the number of viable Legionella, we validated a model mimicking realistic exposure through the use of (i recent technology for aerosol generation and (ii a 3D replicate of the human upper respiratory tract. The model's sensitivity was determined by monitoring the deposition of (i aerosolized water and Tc99m radio-aerosol as controls, and (ii bioaerosols generated from both Escherichia coli and Legionella pneumophila sg 1 suspensions. The numbers of viable Legionella prior to and after nebulization were provided by culture, flow cytometry and qPCR. This study was designed to obtain more realistic data on aerosol inhalation (vs. animal experimentation and deposition at the thoracic region in the context of LD. Upon nebulization, 40% and 48% of the initial Legionella inoculum was made of cultivable and non-cultivable cells, respectively; 0.7% of both populations reached the filter holder mimicking the thoracic region in this setup. These results are in agreement with experimental data based on quantitative microbial risk assessment methods and bring new methods that may be useful for preventing LD.

  7. Size distribution of salbutamol/ipratropium aerosols produced by different nebulizers in the absence and presence of heat and humidification.

    Science.gov (United States)

    Yang, Ssu-Han; Yang, Tsung-Ming; Lin, Hui-Ling; Tsai, Ying-Huang; Fang, Tien-Pei; Wan, Gwo-Hwa

    2018-02-01

    Few studies have evaluated the size distribution of inhaled and exhaled aerosolized drugs, or the effect of heated humidification on particle size and lung deposition. The present study evaluated these aspects of bronchodilator (salbutamol/ipratropium) delivery using a lung model in the absence and presence of heat and humidification. We positioned filters to collect and measure the initial drug, inhaled drug, and exhaled drug. Particle size distribution was evaluated using an 8-stage Marple personal cascade impactor with 0.2-μm polycarbonate filters. A greater inhaled drug mass was delivered using a vibrating mesh nebulizer (VMN) than by using a small volume nebulizer (SVN), when heated humidifiers were not employed. When heated and humidified medical gas was used, there was no significant difference between the inhaled drug mass delivered by the VMN and that delivered by the SVN. A significantly greater mass of inhaled 1.55-μm drug particles was produced by the VMN than with the SVN, under heated and humidified conditions. However, the mass median aerodynamic diameters (MMADs) of the aerosolized drug produced by the SVN and VMN did not differ significantly under the same conditions. The VMN produced more fine particles of salbutamol/ipratropium, and the drug particle size clearly increased in the presence of heat and humidification. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Application of slurry nebulization to trace elemental analysis of some biological samples by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Mochizuki, T.; Sakashita, A.; Iwata, H.; Ishibashi, Y.; Gunji, N.

    1991-01-01

    The application of slurry nebulization/inductively coupled plasma mass spectrometry (ICP-MS) to trace elemental analysis of biological samples has been investigated. Three standard samples of the National Institute of Standards and Technology (NIST) were dispersed in 1% aqueous Triton X-100 solution by grinding with a planetary micronizing mill. The resulting slurries were nebulized into an ICP without any additional treatments. The 1% (m/v) slurry of the NIST bovine liver showed no significant influence on cone blockage and signal suppression/enhancement. Detection limit, precision and accuracy were discussed for the determination of 24 elements of interest in bovine liver, rice flour and pine needles. Detection limits ranged from 0.0001 μg g -1 for U to 0.52 μg g -1 for Zn at the effective integrating time of 10 s. For high mass elements, low blank values were obtained, yielding excellent limits ( -1 ). Acceptable accuracy and precision were obtained for most of the elements in the NIST bovine liver and rice flour, even for the volatile elements, such as As, Se and Br. However, relatively poor accuracy was obtained for the analysis of pine needles. (orig.)

  9. An investigation of the effects of pneumatic actuator design on slip control for heavy vehicles

    Science.gov (United States)

    Miller, Jonathan I.; Cebon, David

    2013-01-01

    Progress in reducing actuator delays in pneumatic brake systems is opening the door for advanced anti-lock braking algorithms to be used on heavy goods vehicles. However, little has been published on slip controllers for air-braked heavy vehicles, or the effects of slow pneumatic actuation on their design and performance. This paper introduces a sliding mode slip controller for air-braked heavy vehicles. The effects of pneumatic actuator delays and flow rates on stopping performance and air (energy) consumption are presented through vehicle simulations. Finally, the simulations are validated with experiments using a hardware-in-the-loop rig. It is shown that for each wheel, pneumatic valves with delays smaller than 3 ms and orifice diameters around 8 mm provide the best performance.

  10. Analysis of vibroprotection characteristics of pneumatic relaxation seat suspension with capability of vibration energy recuperation

    Directory of Open Access Journals (Sweden)

    Lyashenko Mikhail

    2017-01-01

    Full Text Available This paper proposes mechanism and control algorithm for pneumatic relaxation system of suspension with vibration energy recuperation applied to standard vehicle operator seat (“Sibeko” company. Mathematical model of the seat pneumatic relaxation suspension with two additional air volumes was created. Pneumatic motor – recuperator activated by means of air flow from the one additional volume to another is installed in air piping between additional volumes. Computational research was made in Matlab/Simulink. Amplitude-frequency characteristics of transmission coefficient for standard and proposed suspensions were plotted for preliminary evaluation of vibration protection properties of seat suspension. Performed comparative analysis of amplitude-frequency characteristics shows that noticeable improvement of vibration protection properties of pneumatic relaxation suspension system with vibration energy recuperation in comparison with standard system both in region of resonance disturbances and in above-resonance region. Main ways for further improvement of vibration protection properties of proposed system were marked out.

  11. Pneumatic pressure wave generator provides economical, simple testing of pressure transducers

    Science.gov (United States)

    Gaal, A. E.; Weldon, T. P.

    1967-01-01

    Testing device utilizes the change in pressure about a bias or reference pressure level produced by displacement of a center-driven piston in a closed cylinder. Closely controlled pneumatic pressure waves allow testing under dynamic conditions.

  12. Force Control for a Pneumatic Cylinder Using Generalized Predictive Controller Approach

    Directory of Open Access Journals (Sweden)

    Ahmad ’Athif Mohd Faudzi

    2014-01-01

    Full Text Available Pneumatic cylinder is a well-known device because of its high power to weight ratio, easy use, and environmental safety. Pneumatic cylinder uses air as its power source and converts it to a possible movement such as linear and rotary movement. In order to control the pneumatic cylinder, controller algorithm is needed to control the on-off solenoid valve with encoder and pressure sensor as the feedback inputs. In this paper, generalized predictive controller (GPC is proposed as the control strategy for the pneumatic cylinder force control. To validate and compare the performance, proportional-integral (PI controller is also presented. Both controllers algorithms GPC and PI are developed using existing linear model of the cylinder from previous research. Results are presented in simulation and experimental approach using MATLAB-Simulink as the platform. The results show that the GPC is capable of fast response with low steady state error and percentage overshoot compared to PI.

  13. Costs and benefits of pneumatic collection in three specific New York City cases

    International Nuclear Information System (INIS)

    Miller, Benjamin; Spertus, Juliette; Kamga, Camille

    2014-01-01

    Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of

  14. Costs and benefits of pneumatic collection in three specific New York City cases

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Benjamin, E-mail: BenjaminMiller@nyc.rr.com [University Transportation Research Center, Region 2, 910 Marshak Hall, The City College of New York, New York, NY 10031 (United States); Spertus, Juliette, E-mail: Juliette.Spertus@gmail.com [19 Clifton Place, Brooklyn, NY 11238 (United States); Kamga, Camille, E-mail: CKamga@UTRC2.org [University Transportation Research Center, Region 2, 910 Marshak Hall, The City College of New York, New York, NY 10031 (United States)

    2014-11-15

    Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of

  15. Intermittent pneumatic compression of legs increases microcirculation in distant skeletal muscle.

    Science.gov (United States)

    Liu, K; Chen, L E; Seaber, A V; Johnson, G W; Urbaniak, J R

    1999-01-01

    Intermittent pneumatic compression has been established as a method of clinically preventing deep vein thrombosis, but the mechanism has not been documented. This study observed the effects of intermittent pneumatic compression of legs on the microcirculation of distant skeletal muscle. The cremaster muscles of 80 male rats were exposed, a specially designed intermittent pneumatic-compression device was applied to both legs for 60 minutes, and the microcirculation of the muscles was assessed by measurement of the vessel diameter in three categories (10-20, 21-40, and 41-70 microm) for 120 minutes. The results showed significant vasodilation in arterial and venous vessels during the application of intermittent pneumatic compression, which disappeared after termination of the compression. The vasodilation reached a maximum 30 minutes after initiation of the compression and could be completely blocked by an inhibitor of nitric oxide synthase, NG-monomethyl-L-arginine (10 micromol/min). A 120-minute infusion of NG-monomethyl-L-arginine, beginning coincident with 60 minutes of intermittent pneumatic compression, resulted in a significant decrease in arterial diameter that remained at almost the same level after termination of the compression. The magnitude of the decrease in diameter in the group treated with intermittent pneumatic compression and NG-monomethyl-L-arginine was comparable with that in the group treated with NG-monomethyl-L-arginine alone. The results imply that the production of nitric oxide is involved in the positive influence of intermittent pneumatic compression on circulation. It is postulated that the rapid increase in venous velocity induced by intermittent pneumatic compression produces strong shear stress on the vascular endothelium, which stimulates an increased release of nitric oxide and thereby causes systemic vasodilation.

  16. Sliding mode control of a "Soft" 2-DOF Planar Pneumatic Manipulator

    Science.gov (United States)

    Van Damme, M.; Vanderborght, B.; Beyl, P.; Versluys, R.; Vanderniepen, I.; Van Ham, R.; Cherelle, P.; Daerden, F.; Lefeber, D.

    2008-10-01

    This paper presents a sliding mode controller for a "Soft" 2-DOF Planar Pneumatic Manipulator actuated by pleated pneumatic artificial muscle actuators. Since actuator dynamics is not negligible, an approximate model for pressure dynamics was taken into account, which made it necessary to perform full input-output feedback linearization in order to design a sliding mode controller. The design of the controller is presented in detail, and experimental results obtained by implementing the controller are discussed

  17. Pneumatic control system for rapid vertical rectangular movements of heavy loads

    Energy Technology Data Exchange (ETDEWEB)

    Huettel, G; Krause, H [Zentralinstitut fuer Kernforschung, Rossendorf bei Dresden (German Democratic Republic)

    1975-01-01

    A new control system has been developed in order to realize the physically necessary short transition times between the dead points of a pneumatic oscillator even for heavy loads and high working speeds. Integral element of this system is the external control of braking process provided for in addition to the end position brake installed in the working cylinder. This control system is applicable not only to pile oscillators, but also universally applicable to pneumatic apparatuses.

  18. Testing the plant pneumatic method to estimate xylem embolism resistance in stems of temperate trees

    OpenAIRE

    Zhang, Ya; Lamarque, Laurent J.; Torres-Ruiz, José Manuel; Schuldt, Bernhard; Karimi, Zohreh; Li, Shan; Qin, De-Wen; Bittencourt, Paulo; Burlett, Régis; Cao, Kun-Fang; Delzon, Sylvain; Oliveira, Rafael; Pereira, Luciano; Jansen, Steven

    2018-01-01

    Methods to estimate xylem embolism resistance generally rely on hydraulic measurements, which can be far from straightforward. Recently, a pneumatic method based on air flow measurements of terminal branch ends was proposed to construct vulnerability curves by linking the amount of air extracted from a branch with the degree of embolism. We applied this novel technique for 10 temperate tree species, including six diffuse, two ring-porous and two gymnosperm species, and compared the pneumatic ...

  19. Study of a Pneumatic Hybrid aided by a FPGA Controlled Free Valve Technology System

    OpenAIRE

    Trajkovic, Sasa

    2008-01-01

    Urban traffic involves frequent acceleration and deceleration. During deceleration, the energy previously used to accelerate the vehicle is mainly wasted on heat generated by the friction brakes. If this energy that is wasted in traditional IC engines could be saved, the fuel economy would improve. Today there are several solutions to meet the demand for better fuel economy and one of them is the pneumatic hybrids. The idea with pneumatic hybridization is to reduce the fuel con...

  20. Pneumatic Compression, But Not Exercise, Can Avoid Intradialytic Hypotension: A Randomized Trial.

    Science.gov (United States)

    Álvares, Valeria R C; Ramos, Camila D; Pereira, Benedito J; Pinto, Ana Lucia; Moysés, Rosa M A; Gualano, Bruno; Elias, Rosilene M

    2017-01-01

    Conventional hemodialysis (HD) is associated with dialysis-induced hypotension (DIH) and ineffective phosphate removal. As the main source of extracellular fluid removed during HD are the legs, we sought to reduce DIH and increase phosphate removal by using cycling and pneumatic compression, which would potentially provide higher venous return, preserving central blood flow and also offering more phosphate to the dialyzer. We evaluated 21 patients in a randomized crossover fashion in which each patient underwent 3 different HD: control; cycling exercise during the first 60 min; and pneumatic compression during the first 60 min. Data obtained included bioelectrical impedance, hourly blood pressure measurement, biochemical parameters, and direct quantification of phosphate through the dialysate. DIH was defined as a drop in mean arterial pressure (MAP) ≥20 mm Hg. There was no difference in the ultrafiltration rate (p = 0.628), delta weight (p = 0.415), delta of total, intra and extracellular body water among the control, cycling, and pneumatic compression (p = 0.209, p = 0.348, and p = 0.467 respectively). Delta MAP was less changed by pneumatic compression when compared to control, cycling, and pneumatic compression respectively (-4.7 [-17.2, 8.2], -4.7 [-20.5, -0.2], and -2.3 [-8.1, 9.0] mm Hg; p = 0.021). DIH occurred in 43, 38, and 24% of patients in control, cycling, and pneumatic compression respectively (p = 0.014). Phosphate removal did not increase in any intervention (p = 0.486). Higher phosphate removal was dependent on ultrafiltration, pre dialysis serum phosphate, and higher parathyroid hormone. Pneumatic compression during the first hour of dialysis was associated with less DIH, albeit there was no effect on fluid parameters. Neither exercise nor pneumatic compression increased phosphate removal. © 2017 S. Karger AG, Basel.

  1. A study on modelling of a butterfly-type control valve by a pneumatic actuator

    International Nuclear Information System (INIS)

    Hwang, I Cheol; Park, Cheol Jae

    2009-01-01

    This paper studies on the modelling of a butterfly-type control valve actuating by an on-off pneumatic solenoid valve. The mathematical model is composed of nonlinear differential equations three parts: (i) a solenoid valve, (ii) a pneumatic cylinder, (iii) a rotary-type butterfly valve. The flow characteristics of the butterfly control valve is analysed by a computer simulator, then its simple transfer function is identified from the step responses.

  2. Innovation-Prototype. Making hydraulic and/or pneumatic plates using 3D printing technology

    Science.gov (United States)

    Alexa, V.; Rațiu, S. A.; Kiss, I.; Cioată, V. G.; Rackov, M.

    2018-01-01

    Start 3D printing allows hydraulic and/or pneumatic plates to be obtained from a single technological process without requiring further post-production operations. 3D printing with innovative materials in a rich colour range has several advantages such as: time-saving, cost is the same for any type of plate and its reported just to volume, fast and impossible realization of hydraulic and/or pneumatic links compared to traditional and high accuracy technologies.

  3. A pneumatic control system for rapid vertical rectangular movements of heavy loads

    International Nuclear Information System (INIS)

    Huettel, G.; Krause, H.

    1975-01-01

    A new control system has been developed in order to realize the physically necessary short transition times between the dead points of a pneumatic oscillator even for heavy loads and high working speeds. Integral element of this system is the external control of braking process provided for in addition to the end position brake installed in the working cylinder. This control system is applicable not only to pile oscillators, but also universally applicable to pneumatic apparatuses working like that. (author)

  4. Evaluation of Models of Pneumatic Tourniquet in Simulated Out-of-Hospital Use.

    Science.gov (United States)

    Kragh, John F; Aden, James K; Dubick, Michael A

    2016-01-01

    Pneumatic field tourniquets have been recommended for Military medics to stop bleeding from limb wounds, but no comparison of commercially available pneumatic models of tourniquet has been reported. The purpose of this study is to provide laboratory data on the differential performance of models of pneumatic tourniquets to inform decision-making of potential field assessment by military users. Models included the Emergency and Military Tourniquet (EMT), Tactical Pneumatic Tourniquet 2-inch (TPT2), and Tactical Pneumatic Tourniquet 3-inch (TPT3). One user tested the three tourniquet models 30 times each on a manikin to collect data on effectiveness (yes-no bleeding control), pulse cessation, time to stop bleeding, total time of application, after time (after bleeding was stopped), pressure applied, blood loss volume, composite outcome (whether all individual outcomes were good or not), and pump count of the bulb used to inflate the tourniquet. Neither tourniquet effectiveness nor pulse cessation (ρ = 1; likelihood ratio, 0 for both) differed among tourniquet models: all three models had 100% (30 of 30 tests) for both outcomes. The EMT had the best or tied for best performance in time to stop bleeding, total time, after time, pressure blood loss, composite outcome, and pump count. Each of the three models of pneumatic field tourniquet was 100% effective in stopping simulated bleeding. Among the three models, the EMT showed the best or tied for best performance in time to stop bleeding, blood loss, and composite outcomes. All models are suitable for future field assessment among military users. 2016.

  5. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    Science.gov (United States)

    Legin, G A; Bondarchuk, A O; Perebetjuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.

  6. Development of Pneumatic Robot Hand and Construction of Master-Slave System

    Science.gov (United States)

    Tsujiuchi, Nobutaka; Koizumi, Takayuki; Nishino, Shinya; Komatsubara, Hiroyuki; Kudawara, Tatsuwo; Hirano, Masanori

    Recently, research and development has focused on robots that work in place of people. It is necessary for robots to perform the same flexible motions as people. Additionally, such robots need to incorporate high-level safety features in order not to injure people. For creation of such robots, we need to develop a robot hand that functions like a human hand. At the same time, this type of robot hand can be used as an artificial hand. Here, we present artificial muscle-type pneumatic actuators as the driving source of a robot hand that is both safe and flexible. Some development of robot hands using pneumatic actuators has already taken place. But, until now, when a pneumatic actuator is used, a big compressor is needed. So, the driving system also needs to be big; enlargement of the driving system is a major problem. Consequently, in this research, we develop a low-pressure, low-volume pneumatic actuator for driving a robot hand that works flexibly and safely on the assumption that it will be in contact with people. We develop a five-fingered robot hand with pneumatic actuators. And, we construct a master-slave system to enable the robot hand to perform the same operations as a human hand. We make a 1-link arm that has one degree of freedom using a pneumatic actuator, and construct a control system for the 1-link arm and verify its control performance.

  7. Development of myopia as a hazard for workers in pneumatic caissons

    Science.gov (United States)

    Onoo, A; Kiyosawa, M; Takase, H; Mano, Y

    2002-01-01

    Background/aim: Pneumatic caisson engineering has been developed for large civil engineering constructions. Because of complaints of blurred vision by personnel working in pneumatic caissons, the development of myopia was suspected. The aim of this study was to determine the cause of the blurred vision and the mechanism underlying the changes. Methods: 12 caisson workers underwent a complete ophthalmological examination after completing up to 11 weeks of work (4 days/week) in a pneumatic caisson. Six months later, nine of the workers were examined again. Results: Nine subjects were myopic at the initial examination, and seven of these were considered to have developed the myopia after starting to work in the pneumatic caisson. Six months after completion of the work, the mean refractive change was significantly towards hyperopia. Conclusions: The blurred vision in pneumatic caisson workers was in all likelihood due to the development of myopia. The refractive shift towards hyperopia after completion of work in the pneumatic caisson supports this and demonstrates that the changes were temporary. The myopia is similar to the myopia seen in patients treated by hyperbaric oxygen. Careful monitoring of the refraction of caisson workers should be performed for industrial health control. PMID:12386088

  8. Use of the PZK system for pneumatic stowing along mine workings

    Energy Technology Data Exchange (ETDEWEB)

    Makarevich, Yu S; Buzhin, N K; Churakov, V N

    1983-07-01

    The utilization of waste rock for pneumatic stowing in the Komsomolets Donbassa mine with coal seams to 1 m thick and dip angles from 3 to 11/sup 0/ is evaluated. Gate roads used for mine haulage by belt conveyors are controlled by cribbings made of timber and of concrete blocks, particularly at junction of working facese by belt conveyors are controlled by cribbings made of timber and of concrete blocks, particularly at junction of working faces with gate goads. Effects of pneumatic stowing on strata control cost and environmental protection are analyzed. Waste rock which has been dumped at spoil banks on the ground surface is crushed by the PZK system developed by Dongiproshakht. The PZK system is installed underground close to haulage roadways. Crushed rock material with size from 0 to 80 mm and compression strength coefficient from 3 to 5 degrees on the Protod'yakonov scale is hauled by mine cars to working faces and stowed by the DZM-2 pneumatic system. Strips of pneumatic stowing at each side of a gate road are from 12 to 15 m wide. Design of the PZM system and of a rock hopper used for accumulation of crushed rock as well as design of the DZM-2 system are shown in schemes. Economic analysis shows that use of pneumatic stowing reduces roof subsidence in the haulage gate road to 20% and eliminates cribbings. Use of pneumatic stowing for strata control in haulage gate roads economizes 65 rubles per 1 m of gate road.

  9. The Effects of Smartphone-based Nebulizer Therapy Education on Parents' Knowledge and Confidence of Performance in Caring for Children with Respiratory Disease.

    Science.gov (United States)

    Lee, Jung Min; Kim, Shin-Jeong; Min, Hae Young

    This study aimed to identify the effects of smartphone-based nebulizer therapy education on the knowledge and confidence of parents while performing care for their children with respiratory disease. This quasi-experimental study employed a pretest-posttest design using a nonequivalent control group. Data were collected from children's parents who had not used nebulizer therapy for their children previously. Both the groups were given nebulizer therapy education using the same content but different learning methods. The experimental group (n=36) was taught using smartphones, while the control group (n=36) was taught using verbal and paper-based methods. The data were analyzed using the Chi Square test, repeated measures analysis of variance, and t-test. The mean scores on knowledge improvement (F=100.949, psmartphone-based education on nebulizer therapy might be effective in improving parents' knowledge and confidence in performing care for their children. This study suggests that smartphone-based education needs to be considered as an effective educational intervention in providing nursing support for parents of children with respiratory disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. THE DEVELOPMENT OF IODINE BASED IMPINGER SOLUTIONS FOR THE EFFICIENT CAPTURE OF HG USING DIRECT INJECTION NEBULIZATION - INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY ANALYSIS

    Science.gov (United States)

    Inductively coupled plasma mass spectrometry (ICP/MS) with direct injection nebulization (DIN) was used to evaluate novel impinger solution compositions capable of capturing elemental mercury (Hgo) in EPA Method 5 type sampling. An iodine based impinger solutoin proved to be ver...

  11. Design of a repeating pneumatic pellet injector for the Joint European Torus

    International Nuclear Information System (INIS)

    Milora, S.L.; Combs, S.K.; Baylor, L.R.; Sparks, D.O.; Foust, C.R.; Gethers, F.E.

    1987-01-01

    A three-barrel pneumatic pellet injector has been developed for plasma fueling of the Joint European Torus (JET). The versatile device consists of three independent machine-gun-like mechanisms that operate at cryogenic temperatures (14 0 K to 20 0 K). Individual high speed extruders provide a continuous supply of solid deuterium to each gun assembly, where a reciprocating breech-side cutting mechanism forms and chambers cylindrical pellets from the extrusion; deuterium pellets are then accelerated in the gun barrels with controlled amounts of compressed hydrogen gas (pressures up to 100 bars) to velocities ≤ 1.5 km/s. The injector features three nominal pellet sizes (2.7 mm, 4.0 mm, and 6.0 mm) and has been tested at repetition rates of 5 Hz, 2.5 Hz, and 1 Hz, respectively. Each gun is capable of operating (individually or simultaneously) at the design repetition rate for 15-second duration pulses (limited only by the capacity of the extruder feed system). A remote, stand-alone control and data acquisition system is used for injector operation. 7 refs

  12. Design, construction and characterization of pneumatic system for measurement of roughness

    Directory of Open Access Journals (Sweden)

    Germán A. Bacca-Bastidas

    2015-07-01

    Full Text Available This article aims to present the results obtained from the design, construction and characterization of a pneumatic flapper-nozzle amplifier, employed in the measurement of average surface roughness. In the construction of the sensor, low cost materials were used and most pieces were obtained by machining. The data acquisition was performed through PC, using an Arduino interface board. The nonlinear mathematical model of the sensor is based on equations of perfect gas flow through an orifice and the continuity law for a control volume. The characterization of physical parameters obtained through laboratory techniques based on the transient response of the gas pressure in the pressurization and depressurization processes of constant volume chambers, using computational tools for adjusting experimental curves. The validation of the model was based on the specifications of transient response that presents a dynamic system for a step input. For the measurement of the roughness, the mathematical model of average roughness, Ra, was used, and the measured data by the sensor were obtained in sandpapers from P1000 to P2000 size, with reference for validation values of average roughness indicated by the FEPA standard.

  13. Design of a repeating pneumatic pellet injector for the Joint European Torus

    International Nuclear Information System (INIS)

    Milora, S.L.; Combs, S.K.; Baylor, L.R.; Foust, C.R.; Gethers, F.E.; Sparks, D.O.

    1987-01-01

    A three-barrel pneumatic pellet launcher developed at Oak Ridge National Laboratory (ORNL) serves as the principal component of a plasma fueling system for the Joint European Torus (JET). The versatile device consists of three independent machine gun-like mechanisms that operate at cryogenic temperatures (14-20K). Individual high-speed extruders provide a continuous supply of solid deuterium to each gun assembly, where a reciprocating breech-side cutting mechanism forms and chambers cylindrical pellets from the extrusion; the deuterium pellets are then accelerated in the gun barrels with controlled amounts of compressed hydrogen gas (pressures up to 100 bar) to velocities of ≤1.5 km/s. The injector features three nominal pellet sizes (2.7,4.0, and 6.0 mm) and has been tested at pellet repetition rates of 5,2.5, and 1 Hz, respectively. Each gun can operate (individually or simultaneously) at the design repetition rate for 15-s pulses (limited only by the capacity of the extruder feed system). A remote, stand-alone control and data acquisition system is used for injector operation

  14. Particle transport in a He-microchip plasma atomic emission system with an ultrasonic nebulizer for aqueous sample introduction

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Joosuck [Department of Chemistry, Dankook University, 126 Jukjeon-dong, Suji-gu, Yongin-si, Gyeonggi-do, 448-701 (Korea, Republic of); Lim, H.B. [Department of Chemistry, Dankook University, 126 Jukjeon-dong, Suji-gu, Yongin-si, Gyeonggi-do, 448-701 (Korea, Republic of)], E-mail: plasma@dankook.ac.kr

    2008-11-15

    The transport efficiency of dried particles generated from an ultrasonic nebulizer (USN) was studied to improve the analytical performance of a lab-made, He-microchip plasma system, in which a quartz tube ({approx} 1 mm i.d.) was positioned inside the central channel of a poly(dimethylsiloxane) (PDMS) polymer chip. The polymer microchip plasma has the advantages of low cost, small size, easy handling and design, and self-ignition with long stabilization (> 24 h). However, direct introduction of aqueous solution into the microplasma for the detection of metals remains problematic due to plasma instability. In addition, the much smaller size of the system can cause signal suppression due to low transport efficiency. Therefore, knowledge of particle transport efficiency in this microplasma system is required to enhance the sensitivity and stability. The weight of transported particles in the range of 0.02 to 10 mg m{sup -3} was measured using a piezobalance with a precision of 0.4-17.8%, depending on the operating conditions. The significant effects of the USN operating conditions and the physical properties of the tubing, namely, length, inner diameter and surface characteristics, on the number of particles transported from the nebulizer to the microplasma were studied. When selected metals, such as Na, Mg and Pb, at a concentration of 5 mg L{sup -1} were nebulized, transported particles were obtained with a mass range of 0.5-5 mg m{sup -3}, depending on atomic weights. For application of the He-rf-microplasma, the atomic emission system was optimized by changing both the radio frequency (rf) power (60-200 W) and cooling temperature of the USN (- 12-9 deg. C). The limits of detection obtained for K, Na and Cu were 0.26, 0.22, and 0.28 mg L{sup -1}, respectively. These results confirmed the suitable stability and sensitivity of the He-rf-PDMS microchip plasma for application as an atomization source.

  15. Impact of airborne particle size, acoustic airflow and breathing pattern on delivery of nebulized antibiotic into the maxillary sinuses using a realistic human nasal replica.

    Science.gov (United States)

    Leclerc, Lara; Pourchez, Jérémie; Aubert, Gérald; Leguellec, Sandrine; Vecellio, Laurent; Cottier, Michèle; Durand, Marc

    2014-09-01

    Improvement of clinical outcome in patients with sinuses disorders involves targeting delivery of nebulized drug into the maxillary sinuses. We investigated the impact of nebulization conditions (with and without 100 Hz acoustic airflow), particle size (9.9 μm, 2.8 μm, 550 nm and 230 nm) and breathing pattern (nasal vs. no nasal breathing) on enhancement of aerosol delivery into the sinuses using a realistic nasal replica developed by our team. After segmentation of the airways by means of high-resolution computed tomography scans, a well-characterized nasal replica was created using a rapid prototyping technology. A total of 168 intrasinus aerosol depositions were performed with changes of aerosol particle size and breathing patterns under different nebulization conditions using gentamicin as a marker. The results demonstrate that the fraction of aerosol deposited in the maxillary sinuses is enhanced by use of submicrometric aerosols, e.g. 8.155 ± 1.476 mg/L of gentamicin in the left maxillary sinus for the 2.8 μm particles vs. 2.056 ± 0.0474 for the 550 nm particles. Utilization of 100-Hz acoustic airflow nebulization also produced a 2- to 3-fold increase in drug deposition in the maxillary sinuses (e.g. 8.155 ± 1.476 vs. 3.990 ± 1.690 for the 2.8 μm particles). Our study clearly shows that optimum deposition was achieved using submicrometric particles and 100-Hz acoustic airflow nebulization with no nasal breathing. It is hoped that our new respiratory nasal replica will greatly facilitate the development of more effective delivery systems in the future.

  16. Pneumatic artificial muscle actuators for compliant robotic manipulators

    Science.gov (United States)

    Robinson, Ryan Michael

    Robotic systems are increasingly being utilized in applications that require interaction with humans. In order to enable safe physical human-robot interaction, light weight and compliant manipulation are desirable. These requirements are problematic for many conventional actuation systems, which are often heavy, and typically use high stiffness to achieve high performance, leading to large impact forces upon collision. However, pneumatic artificial muscles (PAMs) are actuators that can satisfy these safety requirements while offering power-to-weight ratios comparable to those of conventional actuators. PAMs are extremely lightweight actuators that produce force in response to pressurization. These muscles demonstrate natural compliance, but have a nonlinear force-contraction profile that complicates modeling and control. This body of research presents solutions to the challenges associated with the implementation of PAMs as actuators in robotic manipulators, particularly with regard to modeling, design, and control. An existing PAM force balance model was modified to incorporate elliptic end geometry and a hyper-elastic constitutive relationship, dramatically improving predictions of PAM behavior at high contraction. Utilizing this improved model, two proof-of-concept PAM-driven manipulators were designed and constructed; design features included parallel placement of actuators and a tendon-link joint design. Genetic algorithm search heuristics were employed to determine an optimal joint geometry; allowing a manipulator to achieve a desired torque profile while minimizing the required PAM pressure. Performance of the manipulators was evaluated in both simulation and experiment employing various linear and nonlinear control strategies. These included output feedback techniques, such as proportional-integral-derivative (PID) and fuzzy logic, a model-based control for computed torque, and more advanced controllers, such as sliding mode, adaptive sliding mode, and

  17. Object-Oriented Approach to Modeling Units of Pneumatic Systems

    Directory of Open Access Journals (Sweden)

    Yu. V. Kyurdzhiev

    2014-01-01

    Full Text Available The article shows the relevance of the approaches to the object-oriented programming when modeling the pneumatic units (PU.Based on the analysis of the calculation schemes of aggregates pneumatic systems two basic objects, namely a cavity flow and a material point were highlighted.Basic interactions of objects are defined. Cavity-cavity interaction: ex-change of matter and energy with the flows of mass. Cavity-point interaction: force interaction, exchange of energy in the form of operation. Point-point in-teraction: force interaction, elastic interaction, inelastic interaction, and inter-vals of displacement.The authors have developed mathematical models of basic objects and interactions. Models and interaction of elements are implemented in the object-oriented programming.Mathematical models of elements of PU design scheme are implemented in derived from the base class. These classes implement the models of flow cavity, piston, diaphragm, short channel, diaphragm to be open by a given law, spring, bellows, elastic collision, inelastic collision, friction, PU stages with a limited movement, etc.A numerical integration of differential equations for the mathematical models of PU design scheme elements is based on the Runge-Kutta method of the fourth order. On request each class performs a tact of integration i.e. calcu-lation of the coefficient method.The paper presents an integration algorithm of the system of differential equations. All objects of the PU design scheme are placed in a unidirectional class list. Iterator loop cycle initiates the integration tact of all the objects in the list. One in four iteration makes a transition to the next step of integration. Calculation process stops when any object shows a shutdowns flag.The proposed approach was tested in the calculation of a number of PU designs. With regard to traditional approaches to modeling, the authors-proposed method features in easy enhancement, code reuse, high reliability

  18. Reversible thermo-pneumatic valves on centrifugal microfluidic platforms.

    Science.gov (United States)

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Harun, Sulaiman Wadi; Kazemzadeh, Amin; Rothan, Hussin A; Yusof, Rohana; Madou, Marc

    2015-08-21

    Centrifugal microfluidic systems utilize a conventional spindle motor to automate parallel biochemical assays on a single microfluidic disk. The integration of complex, sequential microfluidic procedures on these platforms relies on robust valving techniques that allow for the precise control and manipulation of fluid flow. The ability of valves to consistently return to their former conditions after each actuation plays a significant role in the real-time manipulation of fluidic operations. In this paper, we introduce an active valving technique that operates based on the deflection of a latex film with the potential for real-time flow manipulation in a wide range of operational spinning speeds. The reversible thermo-pneumatic valve (RTPV) seals or reopens an inlet when a trapped air volume is heated or cooled, respectively. The RTPV is a gas-impermeable valve composed of an air chamber enclosed by a latex membrane and a specially designed liquid transition chamber that enables the efficient usage of the applied thermal energy. Inputting thermo-pneumatic (TP) energy into the air chamber deflects the membrane into the liquid transition chamber against an inlet, sealing it and thus preventing fluid flow. From this point, a centrifugal pressure higher than the induced TP pressure in the air chamber reopens the fluid pathway. The behaviour of this newly introduced reversible valving system on a microfluidic disk is studied experimentally and theoretically over a range of rotational frequencies from 700 RPM to 2500 RPM. Furthermore, adding a physical component (e.g., a hemispherical rubber element) to induce initial flow resistance shifts the operational range of rotational frequencies of the RTPV to more than 6000 RPM. An analytical solution for the cooling of a heated RTPV on a spinning disk is also presented, which highlights the need for the future development of time-programmable RTPVs. Moreover, the reversibility and gas impermeability of the RTPV in the

  19. Modelling of pneumatic muscle actuator using Hill's model with different approximations of static characteristics of artificial muscle

    OpenAIRE

    Piteľ Ján; Tóthová Mária

    2016-01-01

    For modelling and simulation of pneumatic muscle actuators the mathematical dependence of the muscle force on the muscle contraction at different pressures in the muscles is necessary to know. For this purpose the static characteristics of the pneumatic artificial muscle type FESTO MAS-20-250N used in the experiments were approximated. In the paper there are shown some simulation results of the pneumatic muscle actuator dynamics using modified Hill's muscle model, in which four different appr...

  20. Dreams of pneumatic servo and rail way cars in 2010; 2010 nen noyume kukiatsu servo to tetsudo sharyo

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, K. [Tokyo Precision Instruments Co. Ltd., Kanagawa (Japan)

    2000-01-15

    This paper describes pneumatic servo and railway cars. The comfort of railway cars is improved by reducing excess transverse centrifugal force, and longitudinal, transverse and vertical vibration. Pneumatic system plays a large role in the comfort. Pneumatic system is used for doors because of certain open/shut operation and protecting a hand caught in a door from excess tightening pressure. Pneumatic system is also used for mechanical brakes. Pneumatic spring for car suspensions improves the comfort considerably. The orifice and auxiliary tank of a pneumatic spring reduce a spring constant, and give damping to the vibration system of car bodies and springs. To reduce an outward excess centrifugal force by tilting a car body inward at curve, a body tilting equipment is used which is adopted for a pendulum car with pneumatic servo control, and a tilting car with height control of both side pneumatic springs. For transverse damping, semi-active equipment using oil damper is in wide use, while that using pneumatic servo is also in rial use. (NEDO)

  1. Pneumatic Adaptive Absorber: Mathematical Modelling with Experimental Verification

    Directory of Open Access Journals (Sweden)

    Grzegorz Mikułowski

    2016-01-01

    Full Text Available Many of mechanical energy absorbers utilized in engineering structures are hydraulic dampers, since they are simple and highly efficient and have favourable volume to load capacity ratio. However, there exist fields of applications where a threat of toxic contamination with the hydraulic fluid contents must be avoided, for example, food or pharmacy industries. A solution here can be a Pneumatic Adaptive Absorber (PAA, which is characterized by a high dissipation efficiency and an inactive medium. In order to properly analyse the characteristics of a PAA, an adequate mathematical model is required. This paper proposes a concept for mathematical modelling of a PAA with experimental verification. The PAA is considered as a piston-cylinder device with a controllable valve incorporated inside the piston. The objective of this paper is to describe a thermodynamic model of a double chamber cylinder with gas migration between the inner volumes of the device. The specific situation considered here is that the process cannot be defined as polytropic, characterized by constant in time thermodynamic coefficients. Instead, the coefficients of the proposed model are updated during the analysis. The results of the experimental research reveal that the proposed mathematical model is able to accurately reflect the physical behaviour of the fabricated demonstrator of the shock absorber.

  2. Characterisation of a phenomenological model for commercial pneumatic muscle actuators.

    Science.gov (United States)

    Serres, J L; Reynolds, D B; Phillips, C A; Gerschutz, M J; Repperger, D W

    2009-08-01

    This study focuses on the parameter characterisation of a three-element phenomenological model for commercially available pneumatic muscle actuators (PMAs). This model consists of a spring, damping and contractile element arranged in parallel. Data collected from static loading, contraction and relaxation experiments were fitted to theoretical solutions of the governing equation for the three-element model resulting in prediction profiles for the spring, damping and contractile force coefficient. For the spring coefficient, K N/mm, the following relationships were found: K = 32.7 - 0.0321P for 150 < or = P < or = 314 kPa and K = 17 + 0.0179P for 314 < or = P < or = 550 kPa. For the damping coefficient, B Ns/mm, the following relationship was found during contraction: B = 2.90 for 150 < or = P < or = 550 kPa. During relaxation, B = 1.57 for 150 < or = P < or = 372 kPa and B = 0.311 + 0.00338P for 372 < or = P < or = 550. The following relationship for the contractile force coefficient, F(ce) N, was also determined: F(ce) = 2.91P+44.6 for 150 < or = P < or = 550 kPa. The model was then validated by reasonably predicting the response of the PMA to a triangular wave input in pressure under a constant load on a dynamic test station.

  3. The effect of pneumatic tourniquets on skeletal muscle physiology.

    Science.gov (United States)

    Patterson, S; Klenerman, L; Biswas, M; Rhodes, A

    1981-01-01

    The effect of 3- and 5-hour pneumatic tourniquets on skeletal muscle physiology was investigated. Maximum isometric tension development, contraction and half relaxation times were measured in the muscles lying immediately under and distal to the tourniquet. On release of the tourniquet no consistent difference between control and experimental muscles was observed with respect to contraction and half relaxation times; however, there was a marked reduction in maximum isometric tension development. On the sixth day after release of a 5-hour tourniquet, isometric tension was reduced to 2--20 per cent of the control value in the distal muscle and to 40--60 per cent of the control value in the compressed muscle. Six days after a 3-hour tourniquet the compressed muscle tension was reduced to approximately 80 per cent of the control value whilst in the distal muscle, tension development varied from normal to 64 per cent of the control value. Thus it is shown that the effect on muscle contraction after a 3-hour tourniquet is not immediately reversed by the restoration of the blood supply. A reduction in muscle strength follows which may take a week or more to recover.

  4. Variable recruitment in bundles of miniature pneumatic artificial muscles.

    Science.gov (United States)

    DeLaHunt, Sylvie A; Pillsbury, Thomas E; Wereley, Norman M

    2016-09-13

    The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these standard manipulators can experience significant efficiency losses when operated outside their target performance ranges at low actuation pressures. This study considers the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle. Bundles of miniature PAMs are experimentally characterized, their actuation behavior is modeled, and the efficiency gains and losses associated with the application of a variable recruitment control strategy are assessed. This bio-inspired control strategy allows muscle bundles to operate the fewest miniature PAMs necessary to achieve a desired performance objective, improving the muscle bundle's operating efficiency over larger ranges of force generation and displacement. The study also highlights the need for improved PAM fabrication techniques to facilitate the production of identical miniature PAMs for inclusion in muscle bundles.

  5. Design and analysis of coiled fiber reinforced soft pneumatic actuator.

    Science.gov (United States)

    Singh, Gaurav; Xiao, Chenzhang; Hsiao-Wecksler, Elizabeth T; Krishnan, Girish

    2018-04-18

    Fiber reinforced elastomeric enclosures (FREEs) are soft pneumatic actuators that can contract and generate forces upon pressurization. Typical engineering applications utilize FREEs in their straight cylindrical configuration and derive actuation displacement and forces from their ends. However, there are several instances in nature, such as an elephant trunk, snakes and grapevine tendrils, where a spiral configuration of muscle systems is used for gripping, thereby establishing a mechanical connection with uniform force distribution. Inspired by these examples, this paper investigates the constricting behavior of a contracting FREE actuator deployed in a spiral or coiled configuration around a cylindrical object. Force balance is used to model the blocked force of the FREE, which is then related to the constriction force using a string model. The modeling and experimental findings reveal an attenuation in the blocked force, and thus the constriction force caused by the coupling of peripheral contact forces acting in the spiral configuration. The usefulness of the coiled FREE configuration is demonstrated in a soft arm orthosis for crutch users that provides a constriction force around the forearm. This design minimizes injury risk by reducing wrist load and improving wrist posture.

  6. Pneumatic Artificial Muscles Based on Biomechanical Characteristics of Human Muscles

    Directory of Open Access Journals (Sweden)

    N. Saga

    2006-01-01

    Full Text Available This article reports the pneumatic artificial muscles based on biomechanical characteristics of human muscles. A wearable device and a rehabilitation robot that assist a human muscle should have characteristics similar to those of human muscle. In addition, since the wearable device and the rehabilitation robot should be light, an actuator with a high power to weight ratio is needed. At present, the McKibben type is widely used as an artificial muscle, but in fact its physical model is highly nonlinear. Therefore, an artificial muscle actuator has been developed in which high-strength carbon fibres have been built into the silicone tube. However, its contraction rate is smaller than the actual biological muscles. On the other hand, if an artificial muscle that contracts axially is installed in a robot as compactly as the robot hand, big installing space is required. Therefore, an artificial muscle with a high contraction rate and a tendon-driven system as a compact actuator were developed, respectively. In this study, we report on the basic structure and basic characteristics of two types of actuators.

  7. Development of a hybrid pneumatic-power vehicle

    International Nuclear Information System (INIS)

    Huang, K. David; Tzeng, S.-C.

    2005-01-01

    Many complex technologies have been developed and applied to improve the energy efficiency and exhaust emission of an engine under different driving conditions. The overall thermal efficiency of an internal-combustion engine, however, can be maintained at only about 20-30%, with aggravated problems in the design and development, such as overall difficulty, excessive time consumption or excessively high cost. For electric cars, there is still no major technological breakthrough for the rapid recharging of a large capacity battery and detection of remaining power in it. Although all currently available hybrid-power engines are able to lower the amount of exhaust emissions and the fuel consumption of the engine, they are still unable to achieve a stable and optimal running condition immediately after ignition; hence the engine's thermal-efficiency remains low. To solve the aforementioned problems, an innovative concept - a hybrid pneumatic power-system (HPPS), which stores 'flow work' instead of storing electrochemical energy of the battery - is introduced. This innovative power system not only ensures that the internal-combustion ensures optimally but also recycles the exhaust flow to propel the vehicle. The optimization of the internal-combustion and recycling of the exhaust energy can increase the vehicle's efficiency from an original 15% to 33%, an overall increase of 18%

  8. Soft pneumatic actuator skin with piezoelectric sensors for vibrotactile feedback

    Directory of Open Access Journals (Sweden)

    Harshal Arun Sonar

    2016-01-01

    Full Text Available The latest wearable technologies demand more intuitive and sophisticated interfaces for communication, sensing, and feedback closer to the body. Evidently, such interfaces require flexibility and conformity without losing their functionality even on rigid surfaces. Although there has been various research efforts in creating tactile feedback to improve various haptic interfaces and master-slave manipulators, we are yet to see a comprehensive device that can both supply vibratory actuation and tactile sensing. This paper describes a soft pneumatic actuator (SPA based, SPA-skin prototype that allows bidirectional tactile information transfer to facilitate simpler and responsive wearable interface. We describe the design and fabrication of a 1.4 mm-thick vibratory SPA - skin that is integrated with piezoelectric sensors. We examine in detail the mechanical performance compared to the SPA model and the sensitivity of the sensors for the application in vibrotactile feedback. Experimental findings show that this ultra-thin SPA and the unique integration process of the discrete lead zirconate titanate (PZT based piezoelectric sensors achieve high resolution of soft contact sensing as well as accurate control on vibrotactile feedback by closing the control loop.

  9. Perceptual evaluation and acoustic analysis of pneumatic artificial larynx.

    Science.gov (United States)

    Xu, Jie Jie; Chen, Xi; Lu, Mei Ping; Qiao, Ming Zhe

    2009-12-01

    To investigate the perceptual and acoustic characteristics of the pneumatic artificial larynx (PAL) and evaluate its speech ability and clinical value. Prospective study. The study was conducted in the Voice Lab, Department of Otorhinolaryngology, The First Affiliated Hospital of Nanjing Medical University. Forty-six laryngectomy patients using the PAL were rated for intelligibility and fluency of speech. The voice signals of sustained vowel /a/ for 40 healthy controls and 42 successful patients using the PAL were measured by a computer system. The acoustic parameters and sound spectrographs were analyzed and compared between the two groups. Forty-two of 46 patients using the PAL (91.3%) acquired successful speech capability. The intelligibility scores of 42 successful PAL speakers ranged from 71 to 95 percent, and the intelligibility range of four unsuccessful speakers was 30 to 50 percent. The fluency was judged as good or excellent in 42 successful patients, and poor or fair in four unsuccessful patients. There was no significant difference in average fundamental frequency, maximum intensity, jitter, shimmer, and normalized noise energy (NNE) between 42 successful PAL speakers and 40 healthy controls, while the maximum phonation time (MPT) of PAL speakers was slightly lower than that of the controls. The sound spectrographs of the patients using the PAL approximated those of the healthy controls. The PAL has the advantage of a high percentage of successful vocal rehabilitation. PAL speech is fluent and intelligible. The acoustic characteristics of the PAL are similar to those of a normal voice.

  10. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement

    Science.gov (United States)

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2010-01-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system. PMID:21057608

  11. Paper-based Pneumatic Locomotive Robot with Sticky Actuator

    Directory of Open Access Journals (Sweden)

    Du Xiaohan

    2016-01-01

    Full Text Available Demands for small-scale and low-cost robots have witnessed a great increase in recent years [1–5]. This paper introduces the design and fabrication of a novel, simple, low-cost and designer-friendly locomotive robot. The materials and tools to build the robot originate from everyday life. The robot is pneumatically powered and manually controlled by simply pumping and vacuuming the syringe repeatedly, which realizes reliable locomotion by folding and opening of the planes. In order to realize this complicated motion, a “3D Sticky Actuator” is developed. The motion and force analysis of actuator are then modelled by the numerical method to develop the relations between design parameters. This suggests a systematic and user interactive way of manufacturing various shapes of the actuator, depending on user-defined road condition (e.g. obstacles and slopes and other constraints. One key advantage of the paper-based robot is suggested by its high feasibility.

  12. Rapid Pneumatic Transport of Radioactive Samples - RaPToRS

    Science.gov (United States)

    Padalino, S.; Barrios, M.; Sangster, C.

    2005-10-01

    Some ICF neutron activation diagnostics require quick retrieval of the activated sample. Minimizing retrieval times is particularly important when the half-life of the activated material is on the order of the transport time or the degree of radioactivity is close to the background counting level. These restrictions exist in current experiments performed at the Laboratory for Laser Energetics, thus motivating the development of the RaPToRS system. The system has been designed to minimize transportation time while requiring no human intervention during transport or counting. These factors will be important if the system is to be used at the NIF where radiological hazards will be present during post activation. The sample carrier is pneumatically transported via a 4 inch ID PVC pipe to a remote location in excess of 100 meters from the activation site at a speed of approximately 7 m/s. It arrives at an end station where it is dismounted robotically from the carrier and removed from its hermetic package. The sample is then placed by the robot in a counting station. This system is currently being developed to measure back-to-back gamma rays produced by positron annihilation which were emitted by activated graphite. Funded in part by the U.S. DOE under sub contract with LLE at the University of Rochester.

  13. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement.

    Science.gov (United States)

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Dimaio, Simon P; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system.

  14. Characterization of California Central Coast Aquifers using Pneumatic Slug Tests

    Science.gov (United States)

    Aurelius, S.; Platt, D.; Whetsler, B.; Malama, B.

    2017-12-01

    The recent prolonged drought in California, where about 75% of the population depends to some extent ongroundwater, has led to increased stresses on the state's groundwater resources due to reduced recharge andincreased abstraction to supplement dwindling surface water supplies for irrigation and other urban uses.These factors have conspired to cause historic lows in groundwater levels, lost aquifer storage capacity dueincreased potential for land subsidence, and degraded water quality in coastal aquifers faced with increasedrates of seawater intrusion. Groundwater accounts for about a third of the total water uses in California,with some coastal communities being 100% dependent on groundwater. Irrigation accounts for over 60%of all state groundwater withdrawals in California. In light of this, the state of California recently passedthe Sustainable Groundwater Management Act (SGMA) aimed at bringing the State's groundwater basinsinto sustainable regimes of abstraction, recharge and storage. Groundwater ow models are critical to thesuccessful implementation of the SGMA legislation. However, the usefulness of the models is severely limitedby a lack of detailed knowledge of aquifer properties at spatial scales that allow for accurate projections tobe made about groundwater basin sustainability by resource managers. We report here the results of highresolution pneumatic slug tests performed in two shallow aquifers in San Luis Obispo County on the CaliforniaCentral Coast to obtain detailed information about aquifer properties, including permeability and storage,and their spatial variability.

  15. External pneumatic intermittent compression for treatment of dependent pregnancy edema.

    Science.gov (United States)

    Jacobs, M K; McCance, K L; Stewart, M L

    1982-01-01

    A portable external pneumatic intermittent compression (EPIC) device has been successful in reducing peripheral edema. This study explored the effectiveness of EPIC for treating dependent pregnancy edema. In the study, 42 healthy pregnant women received EPIC for 30 minutes at 40 torr while in the left lateral recumbent position: Group One with mid-thigh boots, and Group Two with below-knee boots. Prior to compression, descriptive data were gathered, leg circumference measurements made, and surface skin temperatures recorded for three sites per leg. Vital signs were taken and pedal edema subjectively indexed. Following compression, circumferences, skin temperatures, vital signs, and edema indices were rerecorded. Three volumes were calculated for each leg using a mathematical model of leg segments as conical frustum units. Mean volume reductions for each leg were significant. The mid-thigh-length boots produced greater mean volume decreases. The volume decrease for calf, lower leg, and foot frustum units were significant. EPIC holds promise as a useful treatment for dependent pregnancy edema.

  16. Rod-based Fabrication of Customizable Soft Robotic Pneumatic Gripper Devices for Delicate Tissue Manipulation.

    Science.gov (United States)

    Low, Jin-Huat; Yeow, Chen-Hua

    2016-08-02

    Soft compliant gripping is essential in delicate surgical manipulation for minimizing the risk of tissue grip damage caused by high stress concentrations at the point of contact. It can be achieved by complementing traditional rigid grippers with soft robotic pneumatic gripper devices. This manuscript describes a rod-based approach that combined both 3D-printing and a modified soft lithography technique to fabricate the soft pneumatic gripper. In brief, the pneumatic featureless mold with chamber component is 3D-printed and the rods were used to create the pneumatic channels that connect to the chamber. This protocol eliminates the risk of channels occluding during the sealing process and the need for external air source or related control circuit. The soft gripper consists of a chamber filled with air, and one or more gripper arms with a pneumatic channel in each arm connected to the chamber. The pneumatic channel is positioned close to the outer wall to create different stiffness in the gripper arm. Upon compression of the chamber which generates pressure on the pneumatic channel, the gripper arm will bend inward to form a close grip posture because the outer wall area is more compliant. The soft gripper can be inserted into a 3D-printed handling tool with two different control modes for chamber compression: manual gripper mode with a movable piston, and robotic gripper mode with a linear actuator. The double-arm gripper with two actuatable arms was able to pick up objects of sizes up to 2 mm and yet generate lower compressive forces as compared to elastomer-coated and non-coated rigid grippers. The feasibility of having other designs, such as single-arm or hook gripper, was also demonstrated, which further highlighted the customizability of the soft gripper device, and it's potential to be used in delicate surgical manipulation to reduce the risk of tissue grip damage.

  17. A randomized trial of pneumatic reduction versus hydrostatic reduction for intussusception in pediatric patients.

    Science.gov (United States)

    Xie, Xiaolong; Wu, Yang; Wang, Qi; Zhao, Yiyang; Chen, Guobin; Xiang, Bo

    2017-08-08

    Data of randomly controlled trials comparing the hydrostatic and pneumatic reduction for intussusception in pediatric patients as initial therapy are lacking. The aim of this study was to conduct a randomly controlled trial to compare the effectiveness and safety of the hydrostatic and pneumatic reduction techniques. All intussusception patients who visited West China Hospital of Sichuan University from January 2014 to December 2015 were enrolled in this study in which they underwent pneumatic reduction or hydrostatic reduction. Patients were randomized into ultrasound-guided hydrostatic or X-ray-guided pneumatic reduction group. The data collected includes demographic data, symptoms, signs, and investigations. The primary outcome of the study was the success rate of reduction. And the secondary outcomes of the study were the rates of intestinal perforations and recurrence. A total of 124 children with intussusception who had met the inclusion criteria were enrolled. The overall success rate of this study was 90.32%. Univariable analysis showed that the success rate of hydrostatic reduction with normal saline (96.77%) was significantly higher than that of pneumatic reduction with air (83.87%) (p=0.015). Perforation after reduction was found in only one of the pneumatic reduction group. The recurrence rate of intussusception in the hydrostatic reduction group was 4.84% compared with 3.23% of pneumatic reduction group. Our study found that ultrasound-guided hydrostatic reduction is a simple, safe and effective nonoperative treatment for pediatric patients suffering from intussusceptions, and should be firstly adopted in the treatment of qualified patients. Therapeutic study TYPE OF STUDY: Prospective study. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Aerosol delivery and humidification with the Boussignac continuous positive airway pressure device.

    Science.gov (United States)

    Thille, Arnaud W; Bertholon, Jean-François; Becquemin, Marie-Hélène; Roy, Monique; Lyazidi, Aissam; Lellouche, François; Pertusini, Esther; Boussignac, Georges; Maître, Bernard; Brochard, Laurent

    2011-10-01

    A simple method for effective bronchodilator aerosol delivery while administering continuing continuous positive airway pressure (CPAP) would be useful in patients with severe bronchial obstruction. To assess the effectiveness of bronchodilator aerosol delivery during CPAP generated by the Boussignac CPAP system and its optimal humidification system. First we assessed the relationship between flow and pressure generated in the mask with the Boussignac CPAP system. Next we measured the inspired-gas humidity during CPAP, with several humidification strategies, in 9 healthy volunteers. We then measured the bronchodilator aerosol particle size during CPAP, with and without heat-and-moisture exchanger, in a bench study. Finally, in 7 patients with acute respiratory failure and airway obstruction, we measured work of breathing and gas exchange after a β(2)-agonist bronchodilator aerosol (terbutaline) delivered during CPAP or via standard nebulization. Optimal humidity was obtained only with the heat-and-moisture exchanger or heated humidifier. The heat-and-moisture exchanger had no influence on bronchodilator aerosol particle size. Work of breathing decreased similarly after bronchodilator via either standard nebulization or CPAP, but P(aO(2)) increased significantly only after CPAP aerosol delivery. CPAP bronchodilator delivery decreases the work of breathing as effectively as does standard nebulization, but produces a greater oxygenation improvement in patients with airway obstruction. To optimize airway humidification, a heat-and-moisture exchanger could be used with the Boussignac CPAP system, without modifying aerosol delivery.

  19. Surgical stabilization of internal pneumatic stabilization? A prospective randomized study of management of severe flail chest patients.

    Science.gov (United States)

    Tanaka, Hideharu; Yukioka, Tetsuo; Yamaguti, Yoshihiro; Shimizu, Syoichiro; Goto, Hideaki; Matsuda, Hiroharu; Shimazaki, Syuji

    2002-04-01

    We compared the clinical efficacy of surgical stabilization and internal pneumatic stabilization in severe flail chest patients who required prolonged ventilatory support. Thirty-seven consecutive severe flail chest patients who required mechanical ventilation were enrolled in this study. All the patients received identical respiratory management, including end-tracheal intubation, mechanical ventilation, continuous epidural anesthesia, analgesia, bronchoscopic aspiration, postural drainage, and pulmonary hygiene. At 5 days after injury, surgical stabilization with Judet struts (S group, n = 18) or internal pneumatic stabilization (I group, n = 19) was randomly assigned. Most respiratory management was identical between the two groups except the surgical procedure. Statistical analysis using two-way analysis of variance and Tukey's test was used to compare the groups. Age, sex, Injury Severity Score, chest Abbreviated Injury Score, number of rib fractures, severity of lung contusion, and Pao2/Fio2 ratio at admission were all equivalent in the two groups. The S group showed a shorter ventilatory period (10.8 +/- 3.4 days) than the I group (18.3 +/- 7.4 days) (p < 0.05), shorter intensive care unit stay (S group, 16.5 +/- 7.4 days; I group, 26.8 +/- 13.2 days; p < 0.05), and lower incidence of pneumonia (S group, 24%; I group, 77%; p < 0.05). Percent forced vital capacity was higher in the S group at 1 month and thereafter (p < 0.05). The percentage of patients who had returned to full-time employment at 6 months was significantly higher in the S group (11 of 18) than in the I group (1 of 19). This study proved that in severe flail chest patients, surgical stabilization using Judet struts has beneficial effects with respect to less ventilatory support, lower incidence of pneumonia, shorter trauma intensive care unit stay, and reduced medical cost than internal fixation. Moreover, surgical stabilization with Judet struts improved percent forced vital capacity from the

  20. Levels of muscle enzymes in the serum after esophageal pneumatic dilation in patients with achalasia.

    Science.gov (United States)

    Kimchi, N A; Ron, Y; Abramowich, D; Shirin, H; Scapa, E; Avni, Y

    2005-01-01

    The success rate of pneumatic dilation of the esophagus in patients with achalasia is variable. We aim to assess whether levels of muscle enzymes in the serum are useful for predicting the efficacy of this procedure. Consecutive adults with symptomatic achalasia treated with pneumatic dilation were included. Blood samples were taken immediately before the procedure and after 12, 24 and 32 h. Clinical efficacy of the pneumatic dilation was evaluated on the basis of a symptom score defined prior to, and 2 months after the procedure. Eleven patients underwent 13 pneumatic dilations. In nine patients this was the first dilation attempt. Ten dilations were clinically effective. The study was discontinued after enzyme levels did not show a trend of increase in any of our patients. Moreover, a statistically significant unexpected decrease in creatine phosphokinase values was found 12 h after the procedure, among the 10 successful dilations. We believe that levels of muscle enzymes in the serum cannot predict the efficacy of pneumatic dilation in patients with achalasia.

  1. A Study on the Bandwidth Characteristics of Pleated Pneumatic Artificial Muscles

    Directory of Open Access Journals (Sweden)

    Rino Versluys

    2009-01-01

    Full Text Available Pleated pneumatic artificial muscles have interesting properties that can be of considerable significance in robotics and automation. With a view to the potential use of pleated pneumatic artificial muscles as actuators for a fatigue test bench (high forces and small displacements, the bandwidth characteristics of a muscle-valve system were investigated. Bandwidth is commonly used for linear systems, as the Bode plot is independent of the amplitude of the input signal. However, due to the non-linear behaviour of pleated pneumatic artificial muscles, the system's gain becomes dependent on the amplitude of the input sine wave. As a result, only one Bode plot is insufficient to clearly describe or identify a non-linear system. In this study, the bandwidth of a muscle-valve system was assessed from two perspectives: a varying amplitude and a varying offset of the input sine wave. A brief introduction to pneumatic artificial muscles is given. The concept of pleated pneumatic artificial muscles is explained. Furthermore, the different test methods and experimental results are presented.

  2. Comparison of a pneumatic conveyor and bucket elevator on an energy and economic basis

    Energy Technology Data Exchange (ETDEWEB)

    Rothwell, T.M.; Southwell, P.H. (Agricultural and Energy Engineering Ltd., Moorefield, ON (Canada)); Vigneault, C. (Agricultural Canada Research Station, St-Jean-sur-Richelieu, PQ (Canada))

    1991-07-01

    Tests were performed at a commercial feed mill which was replacing an existing pneumatic conveyor with a bucket elevator, in order to compare the performance of the two types of conveyor on an energy and cost basis. The conveyors were used to transport ground corn from a hammermill at an average grinding rate of 8.5 tonnes/h. At the same conveying rate of ground product, the pneumatic conveyor required a power of 27.5 kW and an energy of 4.77 kWh/tonne while the bucket elevator required a power of 4.7 kW and an energy of 0.88 kWh/tonne. The financial costs of conveying energy were $8,350/y for the pneumatic system and $1,540/y for the bucket elevator, excluding peak demand charges for electricity. The tests therefore demonstrated that a bucket elevator is far more efficient than a pneumatic conveyor and should be considered in the design of new feed mills. For existing mills, a bucket elevator should be considered if there are problems with the pneumatic system already in place or if the capacity of the mill needs to be increased. 2 refs., 2 tabs.

  3. Adaptive robust trajectory tracking control of a parallel manipulator driven by pneumatic cylinders

    Directory of Open Access Journals (Sweden)

    Ce Shang

    2016-04-01

    Full Text Available Due to the compressibility of air, non-linear characteristics, and parameter uncertainties of pneumatic elements, the position control of a pneumatic cylinder or parallel platform is still very difficult while comparing with the systems driven by electric or hydraulic power. In this article, based on the basic dynamic model and descriptions of thermal processes, a controller integrated with online parameter estimation is proposed to improve the performance of a pneumatic cylinder controlled by a proportional valve. The trajectory tracking error is significantly decreased by applying this method. Moreover, the algorithm is expanded to the problem of posture trajectory tracking for the three-revolute prismatic spherical pneumatic parallel manipulator. Lyapunov’s method is used to give the proof of stability of the controller. Using NI-CompactRio, NI-PXI, and Veristand platform as the realistic controller hardware and data interactive environment, the adaptive robust control algorithm is applied to the physical system successfully. Experimental results and data analysis showed that the posture error of the platform could be about 0.5%–0.7% of the desired trajectory amplitude. By integrating this method to the mechatronic system, the pneumatic servo solutions can be much more competitive in the industrial market of position and posture control.

  4. Study of Pneumatic Servo Loading System in Double-Sided Polishing

    International Nuclear Information System (INIS)

    Qian, N; Ruan, J; Li, W

    2006-01-01

    The precise double-sided polishing process is one of the main methods to get the ultra-smooth surface of workpiece. In double-sided polishing machine, a loading system is required to be able to precisely control the load superimposed on the workpiece, while the polishing is being carried out. A pneumatic servo loading system is proposed for this purpose. In the pneumatic servo system, the servo valve, which acts both the electrical to mechanical converter and the power amplifier, has a substantial influence on the performance of the loading system. Therefore a specially designed pneumatic digital servo valve is applied in the control system. In this paper, the construction of the pneumatic servo loading system in double-sided polishing machine and control strategy associated with the digital servo valve are first addressed. The mathematical model of the system established and the hardware of the pneumatic servo system is designed. Finally, the experiments are carried out by measuring the practical load on the workpiece and the quality of the surface finish. It is demonstrated that the error rate of load is less than 5% and a super-smooth surface of silicon wafer with roughness Ra 0.401 nm can be obtained

  5. Variable modulus cellular structures using pneumatic artificial muscles

    Science.gov (United States)

    Pontecorvo, Michael E.; Niemiec, Robert J.; Gandhi, Farhan S.

    2014-04-01

    This paper presents a novel variable modulus cellular structure based on a hexagonal unit cell with pneumatic artificial muscle (PAM) inclusions. The cell considered is pin-jointed, loaded in the horizontal direction, with three PAMs (one vertical PAM and two horizontal PAMs) oriented in an "H" configuration between the vertices of the cell. A method for calculation of the hexagonal cell modulus is introduced, as is an expression for the balance of tensile forces between the horizontal and vertical PAMs. An aluminum hexagonal unit cell is fabricated and simulation of the hexagonal cell with PAM inclusions is then compared to experimental measurement of the unit cell modulus in the horizontal direction with all three muscles pressurized to the same value over a pressure range up to 758 kPa. A change in cell modulus by a factor of 1.33 and a corresponding change in cell angle of 0.41° are demonstrated experimentally. A design study via simulation predicts that differential pressurization of the PAMs up to 2068 kPa can change the cell modulus in the horizontal direction by a factor of 6.83 with a change in cell angle of only 2.75°. Both experiment and simulation show that this concept provides a way to decouple the length change of a PAM from the change in modulus to create a structural unit cell whose in-plane modulus in a given direction can be tuned based on the orientation of PAMs within the cell and the pressure supplied to the individual muscles.

  6. Variable gearing in a biologically inspired pneumatic actuator array

    International Nuclear Information System (INIS)

    Azizi, Emanuel; Roberts, Thomas J

    2013-01-01

    A fundamental feature of pennate muscles is that muscle fibers are oriented at an angle to the line of action and rotate as they shorten, becoming more oblique throughout a contraction. This change in fiber orientation (pennation angle) can amplify the shortening velocity of a fiber and increase output velocity of the muscle. The velocity advantage resulting from dynamic changes in pennation angle can be characterized as a gear ratio (muscle velocity/fiber velocity). A recent study has shown that a pennate muscle's gear ratio varies automatically depending on the load such that a muscle operates with a high gear during rapid contractions and low gear during forceful contractions. We examined whether this variable gearing behavior can be replicated in a pennate array of artificial muscles. We used McKibben type pneumatic actuators, which shorten in tension when filled with compressed gas. Similar to muscle fibers, the actuators expand radially during shortening, a feature thought to be a critical part of the variable gearing mechanism in pennate muscles. We arranged McKibben actuators in an array oriented to mimic a pennate muscle, and quantified the system's gear ratio during contraction against a range of loads. Video was used to measure the gear ratio during each contraction. We find that similar to pennate muscles, the gear ratio decreases significantly with increasing load and that variable gearing results from load-dependent variation in the amount of actuator rotation. These results support the idea that variable gearing in pennate muscles is mediated by difference is fiber rotation and the direction of muscle bulging. The behavior of our artificial muscle array also highlights the potential benefits of bio-inspired architectures in artificial muscle arrays, including the ability to vary force and speed automatically in response to variable loading conditions. (paper)

  7. Soft Pneumatic Actuator Fascicles for High Force and Reliability.

    Science.gov (United States)

    Robertson, Matthew A; Sadeghi, Hamed; Florez, Juan Manuel; Paik, Jamie

    2017-03-01

    Soft pneumatic actuators (SPAs) are found in mobile robots, assistive wearable devices, and rehabilitative technologies. While soft actuators have been one of the most crucial elements of technology leading the development of the soft robotics field, they fall short of force output and bandwidth requirements for many tasks. In addition, other general problems remain open, including robustness, controllability, and repeatability. The SPA-pack architecture presented here aims to satisfy these standards of reliability crucial to the field of soft robotics, while also improving the basic performance capabilities of SPAs by borrowing advantages leveraged ubiquitously in biology; namely, the structured parallel arrangement of lower power actuators to form the basis of a larger and more powerful actuator module. An SPA-pack module consisting of a number of smaller SPAs will be studied using an analytical model and physical prototype. Experimental measurements show an SPA pack to generate over 112 N linear force, while the model indicates the benefit of parallel actuator grouping over a geometrically equivalent single SPA scale as an increasing function of the number of individual actuators in the group. For a module of four actuators, a 23% increase in force production over a volumetrically equivalent single SPA is predicted and validated, while further gains appear possible up to 50%. These findings affirm the advantage of utilizing a fascicle structure for high-performance soft robotic applications over existing monolithic SPA designs. An example of high-performance soft robotic platform will be presented to demonstrate the capability of SPA-pack modules in a complete and functional system.

  8. Variable gearing in a biologically inspired pneumatic actuator array.

    Science.gov (United States)

    Azizi, Emanuel; Roberts, Thomas J

    2013-06-01

    A fundamental feature of pennate muscles is that muscle fibers are oriented at an angle to the line of action and rotate as they shorten, becoming more oblique throughout a contraction. This change in fiber orientation (pennation angle) can amplify the shortening velocity of a fiber and increase output velocity of the muscle. The velocity advantage resulting from dynamic changes in pennation angle can be characterized as a gear ratio (muscle velocity/fiber velocity). A recent study has shown that a pennate muscle's gear ratio varies automatically depending on the load such that a muscle operates with a high gear during rapid contractions and low gear during forceful contractions. We examined whether this variable gearing behavior can be replicated in a pennate array of artificial muscles. We used McKibben type pneumatic actuators, which shorten in tension when filled with compressed gas. Similar to muscle fibers, the actuators expand radially during shortening, a feature thought to be a critical part of the variable gearing mechanism in pennate muscles. We arranged McKibben actuators in an array oriented to mimic a pennate muscle, and quantified the system's gear ratio during contraction against a range of loads. Video was used to measure the gear ratio during each contraction. We find that similar to pennate muscles, the gear ratio decreases significantly with increasing load and that variable gearing results from load-dependent variation in the amount of actuator rotation. These results support the idea that variable gearing in pennate muscles is mediated by difference is fiber rotation and the direction of muscle bulging. The behavior of our artificial muscle array also highlights the potential benefits of bio-inspired architectures in artificial muscle arrays, including the ability to vary force and speed automatically in response to variable loading conditions.

  9. VARIABLE GEARING IN A BIOLOGICALLY-INSPIRED PNEUMATIC ACTUATOR ARRAY

    Science.gov (United States)

    Azizi, Emanuel; Roberts, Thomas J.

    2013-01-01

    A fundamental feature of pennate muscles is that muscle fibers are oriented at an angle to the line of action and rotate as they shorten, becoming more oblique throughout a contraction. This change in fiber orientation (pennation angle) can amplify the shortening velocity of a fiber and increase output velocity of the muscle. The velocity advantage resulting from dynamic changes in pennation angle can be characterized as a gear ratio (muscle velocity/fiber velocity). A recent study has shown that a pennate muscle’s gear ratio varies automatically depending on the load such that a muscle operates with a high gear during rapid contractions and low gear during forceful contractions. We examined whether this variable gearing behavior can be replicated in a pennate array of artificial muscles. We used McKibben type pneumatic actuators, which shorten in tension when filled with compressed gas. Similar to muscle fibers, the actuators expand radially during shortening, a feature thought to be a critical part of the variable gearing mechanism in pennate muscles. We arranged McKibben actuators in an array oriented to mimic a pennate muscle, and quantified the system’s gear ratio during contraction against a range of loads. Video was used to measure the gear ratio during each contraction. We find that similar to pennate muscles, the gear ratio decreases significantly with increasing load and that variable gearing results from load-dependent variation in the amount of actuator rotation. These results support the idea that variable gearing in pennate muscles is mediated by difference is fiber rotation and the direction of muscle bulging. The behavior of our artificial muscle array also highlights the potential benefits of bio-inspired architectures in artificial muscle arrays, including the ability to vary force and speed automatically in response to variable loading conditions. PMID:23462288

  10. Soft Pneumatic Actuator Fascicles for High Force and Reliability

    Science.gov (United States)

    Robertson, Matthew A.; Sadeghi, Hamed; Florez, Juan Manuel

    2017-01-01

    Abstract Soft pneumatic actuators (SPAs) are found in mobile robots, assistive wearable devices, and rehabilitative technologies. While soft actuators have been one of the most crucial elements of technology leading the development of the soft robotics field, they fall short of force output and bandwidth requirements for many tasks. In addition, other general problems remain open, including robustness, controllability, and repeatability. The SPA-pack architecture presented here aims to satisfy these standards of reliability crucial to the field of soft robotics, while also improving the basic performance capabilities of SPAs by borrowing advantages leveraged ubiquitously in biology; namely, the structured parallel arrangement of lower power actuators to form the basis of a larger and more powerful actuator module. An SPA-pack module consisting of a number of smaller SPAs will be studied using an analytical model and physical prototype. Experimental measurements show an SPA pack to generate over 112 N linear force, while the model indicates the benefit of parallel actuator grouping over a geometrically equivalent single SPA scale as an increasing function of the number of individual actuators in the group. For a module of four actuators, a 23% increase in force production over a volumetrically equivalent single SPA is predicted and validated, while further gains appear possible up to 50%. These findings affirm the advantage of utilizing a fascicle structure for high-performance soft robotic applications over existing monolithic SPA designs. An example of high-performance soft robotic platform will be presented to demonstrate the capability of SPA-pack modules in a complete and functional system. PMID:28289573

  11. Initial Design and Experimental Evaluation of a Pneumatic Interference Actuator.

    Science.gov (United States)

    Nesler, Christopher R; Swift, Tim A; Rouse, Elliott J

    2018-04-01

    Substantial device mass and control complexity can hinder the impact of wearable robotic technologies, such as exoskeletons. Thus, despite promising previous research, the development of a simple, lightweight actuator for these systems has not yet been fully realized. The purpose of this study was to derive and demonstrate a proof-of-concept for a pneumatic interference actuator (PIA)-a lightweight, soft actuator able to produce torque by the self-intersection of a fabric balloon that arises from changes in physical geometry. General closed-form equations are derived to express the expected actuator torque and mechanical work as functions of the balloon geometry, pressure, and deflection angle. Hard and soft cylindrical physical prototypes were constructed to assess the accuracy of the mathematical models. The proposed mathematical model was found to agree with the pressure-volume relationship and successfully predict the maximum torque as a function of geometry, pressure, and deflection at nonzero deflection angles. Peak powers up to 122.1 ± 10.0 W (mean ± standard deviation), with a resting internal pressure of 158.0 ± 0.2 kPa, were observed from the hard actuator prototype. For the soft actuator prototype, peak powers of 97.9 ± 21.1 W were observed at a resting pressure of 166.8 kPa. The work performed was within 3.2% ± 3.4% and 14.4% ± 8.2% of theoretical values across all trials, and within 19.1% ± 4.4% of theoretical values when compared to the torque-angle relationship. This study highlights the promise of utilizing the self-intersection of a PIA to perform human-scale mechanical work, and future research will focus on implementations for wearable robotic systems.

  12. Clinical characteristics affecting the outcome of pneumatic retinopexy.

    Science.gov (United States)

    Davis, Michael J; Mudvari, Sachin S; Shott, Susan; Rezaei, Kourous A

    2011-02-01

    To review characteristics and outcomes of patients who underwent primary pneumatic retinopexy (PR) for repair of rhegmatogenous retinal detachment in a multioffice retina practice and to determine what preoperative characteristics were associated with success or failure of PR. A retrospective medical record review was conducted of patients who underwent primary PR from September 2001 to March 2009. Patients with less than 6 months of follow-up were excluded. Data collected on each patient included age, sex, affected eye, preoperative visual acuity, lens status, presence of posterior vitreous detachment, presence of vitreous hemorrhage, macular status, presence of lattice degeneration, number and location of retinal breaks, clock hour extent of detachment, final visual acuity, final retinal status, number of procedures to reattach retina, and duration of follow-up. Two hundred thirteen patients were included. The mean age was 59.3 years and 53.5% were male. Mean follow-up was 24.6 months, and 64.8% of patients had a successful PR. Vitreous hemorrhage and retinal detachment greater than 4.5 clock hours were the 2 factors that significantly affected successful outcome (P = .04 and .01, respectively). The overall mean final visual acuity was 20/40, with a mean of 20/30 in the success group and a mean of 20/60 in the failure group (P treatment option for certain types of rhegmatogenous retinal detachment. In patients with vitreous hemorrhage and detachments greater than 4.5 clock hours, the success rate may be lower. Final visual acuity is better with successful reattachment with a single procedure.

  13. Current visual and anatomic outcomes of pneumatic retinopexy.

    Science.gov (United States)

    Kulkarni, Kaushal M; Roth, Daniel B; Prenner, Jonathan L

    2007-10-01

    To assess current visual and anatomic outcomes of pneumatic retinopexy (PR) for the repair of rhegmatogenous retinal detachment (RD). Retrospective chart review of 150 patients who underwent PR for RD between January 2000 and February 2005. Patients with a history of scleral buckling, Lincoff balloon, or proliferative diabetic retinopathy in the same eye were excluded. Successful reattachment was achieved in 76.7% with a single procedure and 98.7% after additional procedures. A total of 17.3% underwent a subsequent procedure for a new or persistent tear. The success rate remained consistent in pseudophakic and aphakic eyes, and eyes with traumatic detachments, macular detachment, multiple breaks, poor preoperative visual acuity (VA) (lattice degeneration, >or=6 clock hours of detachment, and prior pars plana vitrectomy. A total of 2.7% of eyes underwent a second additional procedure for RD. A total of 32% of males versus 15.3% of females underwent an additional procedure for RD (P = 0.07). Final VA >or=20/50 was achieved in 80.8% of macula-on and 73.6% of macula-off RDs. Of eyes that underwent an additional procedure, final VA >or=20/50 was achieved in 63.2% of macula-on and 43.8% of macula-off RDs, and those with macula-on RD lost a mean of 1.79 (+/-4.9) lines of Snellen VA, while those with macula-off RD gained a mean of 5.6 (+/-4.6) lines (P = 0.00006). : PR had a high anatomic success rate in eyes with a wide variety of complicated RDs. Male sex may be a risk factor for failed PR. Careful monitoring and treatment of postoperative tears is important in preventing redetachment.

  14. Design and analysis of adaptive honeycomb structure with pneumatic muscle fibers

    Science.gov (United States)

    Yin, Weilong; Tian, Dongkui; Chen, Yijin

    2012-04-01

    The adaptive honeycomb structure actuated by pneumatic muscle fibers is proposed in this paper. The FE model of adaptive honeycomb structure is developed by use of ANSYS software. The elastics modulus of the developed pneumatic muscle fibers is experimentally determined and their output force is tested. The results show that the contraction ratio of the pneumatic muscle fibers with inner diameter of 2mm could reach up to 26.8% and the force could reach to a value of 27N when the applied pressure is 0.4MPa and the contraction ratio is zero. When the adaptive honeycomb has a certain load and an effective output displacement, the applied force must be greater than a certain value. The adaptive honeycomb must be consumed extra energy when the output displacement and force are produced.

  15. Transient Torsional Analysis of a Belt Conveyor Drive with Pneumatic Flexible Shaft Coupling

    Directory of Open Access Journals (Sweden)

    Kaššay Peter

    2017-03-01

    Full Text Available Development and application of pneumatic flexible shaft couplings have been in the center of our department research activities for a long time. These couplings are able to change torsional stiffness by changing pressure in their flexible elements – air bellows. Until now we have dealt with the use of pneumatic flexible shaft couplings for tuning mechanical systems working with periodically alternating load torque at steady state. Some mechanical systems, however, operate with a static load torque at constant speed (e.g. hoists, elevators, etc., where it is necessary to consider the suitability of shaft coupling in terms of load torque at transient conditions (run-up and braking. Therefore we decided to analyze the use of pneumatic flexible shaft couplings also in this type of mechanical systems on an example of conveyor belt drive.

  16. Comparation of the impact of selected technical gases on properties of a pneumatic flexible coupling

    Directory of Open Access Journals (Sweden)

    Grega Robert

    2018-01-01

    Full Text Available An important part of the oscillating mechanical drives are flexible shaft couplings. The special use of the pneumatic flexible coupling is possibility to serve as mechanical drives tuners. Being examined in tuners mechanical drives there is also a research focus on the impact of industrial gases on the change of dynamic characteristics of pneumatic couplings. The paper investigates five different industrial gases, namely: air, helium (He-4.6, a mixture of propane and butane gas (C3H8+C4H10, argon (Ar and nitrogen (N2 to see how these gases affect the dynamic characteristics of pneumatic flexible shaft coupling with marking 4-2/70 T-C.

  17. Characterization of a piezoelectric valve for an adaptive pneumatic shock absorber

    International Nuclear Information System (INIS)

    Mikułowski, Grzegorz; Wiszowaty, Rafał; Holnicki-Szulc, Jan

    2013-01-01

    This paper describes a pneumatic valve based on a multilayer piezoelectric actuator and Hörbiger plates. The device was designed to operate in an adaptive pneumatic shock absorber. The adaptive pneumatic shock absorber was considered as a piston–cylinder device and the valve was intended to be installed inside the piston. The main objective for the valve application was regulating the gas flow between the cylinder’s chambers in order to maintain the desired value of the reaction force generated by the shock absorber. The paper describes the design constraints and requirements, together with results of analytical modelling of fluid flow verified versus experimentally obtained data. The presented results indicate that the desired performance characteristics of the valve were obtained. The geometrical constraints of the flow ducts were studied and the actuator’s functional features analysed. (paper)

  18. Arrested pneumatization of the sphenoid sinus mimicking intraosseous lesions of the skull base

    Energy Technology Data Exchange (ETDEWEB)

    Jalali, Elnaz; Tadinada, Aditya [Dept. of Oral and Maxillofacial Radiology, University of Connecticut School of Dental Medicine, Farmington (United States)

    2015-03-15

    Arrested pneumatization of the sphenoid sinus is a developmental variant that is not always well recognized and is often confused with other pathologies associated with the skull base. This report describes the case of a patient referred for cone-beam computed tomography (CBCT) imaging for dental implant therapy. CBCT demonstrated a well-defined incidental lesion in the left sphenoid sinus with soft tissue-like density and sclerotic borders with internal curvilinear opacifications. The differential diagnoses included intraosseous lipoma, arrested pneumatization of the sphenoid sinus, chondrosarcoma, chondroid chordoma, and ossifying fibroma. The radiographic diagnosis of arrested pneumatization was based on the location of the lesion, its well-defined nature, the presence of internal opacifications, and lack of expansion. Gray-scale CBCT imaging of the area demonstrated values similar to fatty tissue. This case highlighted the fact that benign developmental variants associated with the skull base share similar radiographic features with more serious pathological entities.

  19. Development of a pneumatic transport system for bulk transfer of metal grade uranium oxide powder

    International Nuclear Information System (INIS)

    Manna, S.; Satpati, S.K.; Roy, S.B.

    2010-01-01

    Uranium oxide powder is a commonly handled ceramic powder in nuclear industries. Design of the powder transfer system is an important aspect because of some of its typical characteristics. Pneumatic transport system has been widely used in transferring powder from one place to another. A pneumatic transport system using vacuum has been presented in the paper. This is used for bulk transfer of UO 3 powder. The system consists of a cyclone separator and filter cloth at the top of the cyclone separator. The pneumatic transfer system provides high efficiency with sustainable performance and it is a compact, robust, handy and moveable unit. No degradation of the powder quality has been observed during transfer. The system provides highly efficient, easy and safe transfer of radioactive powder, better working environment for the operator. (author)

  20. Pneumatic Rotary Actuator Position Servo System Based on ADE-PD Control

    Directory of Open Access Journals (Sweden)

    Yeming Zhang

    2018-03-01

    Full Text Available In order to accurately control the rotation position of a pneumatic rotary actuator, the flow state of the gas and the motion state of the pneumatic rotary actuator in the pneumatic rotary actuator position servo system are analyzed in this paper. The mathematical model of the system and the experiment platform are established after that. An Adaptive Differential Evolution (ADE algorithm which adaptively ameliorates the scaling factor and crossover probability in the process of individual evolution is proposed and applied to the parameter optimization of PD controller. The experimental platform is used to compare the controller with Differential Evolution (DE algorithm and NCD-PID controller. Finally, the characteristics of the system are tested by increasing the inertial load. The experimental results illustrate that system using ADE-PD control strategy has greater position precision and faster response than using DE-PD and NCD-PID strategies, and shows great robustness.

  1. Novel Design of a Soft Lightweight Pneumatic Continuum Robot Arm with Decoupled Variable Stiffness and Positioning.

    Science.gov (United States)

    Giannaccini, Maria Elena; Xiang, Chaoqun; Atyabi, Adham; Theodoridis, Theo; Nefti-Meziani, Samia; Davis, Steve

    2018-02-01

    Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally.

  2. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide

    International Nuclear Information System (INIS)

    Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun

    2014-01-01

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass

  3. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide

    Science.gov (United States)

    Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun

    2014-07-01

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  4. Powered Upper Limb Orthosis Actuation System Based on Pneumatic Artificial Muscles

    Science.gov (United States)

    Chakarov, Dimitar; Veneva, Ivanka; Tsveov, Mihail; Venev, Pavel

    2018-03-01

    The actuation system of a powered upper limb orthosis is studied in the work. To create natural safety in the mutual "man-robot" interaction, an actuation system based on pneumatic artificial muscles (PAM) is selected. Experimentally obtained force/contraction diagrams for bundles, consisting of different number of muscles are shown in the paper. The pooling force and the stiffness of the pneumatic actuators is assessed as a function of the number of muscles in the bundle and the supply pressure. Joint motion and torque is achieved by antagonistic actions through pulleys, driven by bundles of pneumatic muscles. Joint stiffness and joint torques are determined on condition of a power balance, as a function of the joint position, pressure, number of muscles and muscles

  5. The use of automation with the new pneumatic irradiation facility of the ORNL HFIR

    International Nuclear Information System (INIS)

    Dyer, F.F.; Robinson, L.; Emery, J.F.

    1988-01-01

    The High Flux Isotope Reactor at Oak Ridge National Laboratory has two pneumatic irradiation systems: PT-1 installed in 1970 and PT-2 installed in 1987, which are used for neutron activation analysis. Both systems have been described in the literature. By means of a Gould programmable controller, considerable progress has been made in a cost-effective manner to operate and automate the features of the new facility. A neutron counter is an integral part of the new pneumatic tube, and all of the hardware is present to enable automated delayed neutron counting. Some automation of the old system has also been accomplished by the use of a Zymark general purpose programmable robot. This paper describes the automated features of both systems. The reactor has been shut down for safety evaluation since November 1986, so that no irradiations have been made in the new pneumatic tube

  6. Expediency of using pneumatic balloons at the junction of a working face and gate roads

    Energy Technology Data Exchange (ETDEWEB)

    Kolokolov, O V; Litvinov, Yu G; Ozerova, A S

    1983-02-01

    The paper discusses strata control at longwall faces in thin coal seams. Use of pneumatic balloons instead of timber cribbing at the junction of the face and ventilation road is evaluated. The seam is 0.68 m thick at a depth of 980 m and has gradients from 60 to 63 degrees. The face mined by the Poisk coal cutter is 126 m long. The ventilation road is protected by strips of stowing. Use of pneumatic balloons with an initial pressure of 150 kN instead of timber cribbing with an initial pressure of 30 kN reduces convergence of the roof and the floor at the working face by 39%. Damage to hydraulic props at the working face caused by roof subsidence decreases by 10 to 15%. Convergence rate (measured in mm/d) decreases by 41%. Use of pneumatic balloons for strata control at working faces in thin coal seams is recommended.

  7. Characterization of a piezoelectric valve for an adaptive pneumatic shock absorber

    Science.gov (United States)

    Mikułowski, Grzegorz; Wiszowaty, Rafał; Holnicki-Szulc, Jan

    2013-12-01

    This paper describes a pneumatic valve based on a multilayer piezoelectric actuator and Hörbiger plates. The device was designed to operate in an adaptive pneumatic shock absorber. The adaptive pneumatic shock absorber was considered as a piston-cylinder device and the valve was intended to be installed inside the piston. The main objective for the valve application was regulating the gas flow between the cylinder’s chambers in order to maintain the desired value of the reaction force generated by the shock absorber. The paper describes the design constraints and requirements, together with results of analytical modelling of fluid flow verified versus experimentally obtained data. The presented results indicate that the desired performance characteristics of the valve were obtained. The geometrical constraints of the flow ducts were studied and the actuator’s functional features analysed.

  8. Torque characteristics of a 122-centimeter butterfly valve with a hydro/pneumatic actuator

    Science.gov (United States)

    Lin, F. N.; Moore, W. I.; Lundy, F. E.

    1981-01-01

    Actuating torque data from field testing of a 122-centimeter (48 in.) butterfly valve with a hydro/pneumatic actuator is presented. The hydraulic cylinder functions as either a forward or a reverse brake. Its resistance torque increases when the valve speeds up and decreases when the valve slows down. A reduction of flow resistance in the hydraulic flow path from one end of the hydraulic cylinder to the other will effectively reduce the hydraulic resistance torque and hence increase the actuating torque. The sum of hydrodynamic and friction torques (combined resistance torque) of a butterfly valve is a function of valve opening time. An increase in the pneumatic actuating pressure will result in a decrease in both the combined resistance torque and the actuator opening torque; however, it does shorten the valve opening time. As the pneumatic pressure increases, the valve opening time for a given configuration approaches an asymptotical value.

  9. Design and use of the ORNL HFIR [High Flux Isotope Reactor] pneumatic tube irradiation systems

    International Nuclear Information System (INIS)

    Dyer, F.F.; Emery, J.F.; Robinson, L.; Teasley, N.A.

    1987-01-01

    A second pneumatic tube that was recently installed in the High Flux Isotope Reactor for neutron activation analysis is described. Although not yet tested, the system is expected to have a thermal neutron flux of about 1.5 x 10 14 cm -2 s -1 . A delayed neutron counter is an integral part of the pneumatic tube, and all of the hardware is present to enable automated use of the counter. The system is operated with a Gould programmable controller that is programmed with an IBM personal computer. Automation of any mode of operation, including the delayed neutron counter, will only require a nominal amount of software development. Except for the lack of a hot cell, the irradiation facility has all of the advantageous features of an older pneumatic tube that has been in operation for 17 years. The design of the system and some applications and methods of operation are described

  10. Development of Hybrid Type Flexible Pneumatic Cylinder for Considering Less Air Consumption

    Directory of Open Access Journals (Sweden)

    Tamaki Hiroaki

    2016-01-01

    Full Text Available Inexpensive rehabilitation devices that can be used at home are required because of a lack of PT and welfare workers. In the previous study, the low-cost portable rehabilitation device using a flexible spherical actuator that consists of flexible pneumatic cylinder was proposed and tested. However, a compact and high power compressor that supplies air pressure to pneumatic actuator has not been developed yet. In particular, the heat generated by compressing air prevents to miniaturize it. To realize a home rehabilitation, the small-sized compressors or less air consuming flexible actuators are required. In this study, a hybrid type flexible pneumatic cylinder driven by electric motors and air pressure is proposed and tested. The concept, the construction and the operating principle of the proposed actuator were described. The position control using the tested actuator is also carried out.

  11. System Identification and Embedded Controller Design for Pneumatic Actuator with Stiffness Characteristic

    Directory of Open Access Journals (Sweden)

    Khairuddin Osman

    2014-01-01

    Full Text Available This paper presents model and controller design applications to pneumatic actuator embedded system. Two model strategies of position and force are proposed to realize compliance control for stiffness characteristic. Model of the pneumatic actuator system (transfer function is obtained from system identification (SI method. Next, combination of predictive functional control with observer (PFC-O design is selected as a new control strategy for pneumatic system. Performance assessment of the controller is performed in MATLAB and validated through real-time experiments using national instrument (NI devices and programmable system on chip (PSoC microcontroller. Result shows that the new controller is adapted to the system and able to successfully control both simulation and real-time experiments.

  12. Dosing Accuracy of Insulin Aspart FlexPens After Transport Through the Pneumatic Tube System.

    Science.gov (United States)

    Ward, Leah G; Heckman, Michael G; Warren, Amy I; Tran, Kimberly

    2013-01-01

    The purpose of this study was to evaluate whether transporting insulin aspart FlexPens via a pneumatic tube system affects the dosing accuracy of the pens. A total of 115 Novo Nordisk FlexPens containing insulin aspart were randomly assigned to be transported via a pneumatic tube system (n = 92) or to serve as the control (n = 23). Each pen was then randomized to 10 international unit (IU) doses (n = 25) or 30 IU doses (n = 67), providing 600 and 603 doses, respectively, for the pneumatic tube group. The control group also received random assignment to 10 IU doses (n = 6) or 30 IU doses (n = 17), providing 144 and 153 doses, respectively. Each dose was expelled using manufacturer instructions. Weights were recorded, corrected for specific gravity, and evaluated based on acceptable International Organization for Standardization (ISO) dosing limits. In the group of pens transported through the pneumatic tube system, none of the 600 doses of 10 IU (0.0%; 95% CI, 0.0 to 0.6) and none of the 603 doses of 30 IU (0.0%; 95% CI, 0.0 to 0.6) fell outside of the range of acceptable weights. Correspondingly, in the control group, none of the 144 doses at 10 IU (0.0%; 95% CI, 0.0 to 2.5) and none of the 153 doses at 30 IU (0.0%; 95% CI, 0.0 to 2.4) were outside of acceptable ISO limits. Transportation via pneumatic tube system does not appear to compromise dosing accuracy. Hospital pharmacies may rely on the pneumatic tube system for timely and accurate transport of insulin aspart FlexPens.

  13. Enema reduction of intussusception: the success rate of hydrostatic and pneumatic reduction.

    Science.gov (United States)

    Khorana, Jiraporn; Singhavejsakul, Jesda; Ukarapol, Nuthapong; Laohapensang, Mongkol; Wakhanrittee, Junsujee; Patumanond, Jayanton

    2015-01-01

    Intussusception is a common surgical emergency in infants and children. The incidence of intussusception is from one to four per 2,000 infants and children. If there is no peritonitis, perforation sign on abdominal radiographic studies, and nonresponsive shock, nonoperative reduction by pneumatic or hydrostatic enema can be performed. The purpose of this study was to compare the success rates of both the methods. Two institutional retrospective cohort studies were performed. All intussusception patients (ICD-10 code K56.1) who had visited Chiang Mai University Hospital and Siriraj Hospital from January 2006 to December 2012 were included in the study. The data were obtained by chart reviews and electronic databases, which included demographic data, symptoms, signs, and investigations. The patients were grouped according to the method of reduction followed into pneumatic reduction and hydrostatic reduction groups with the outcome being the success of the reduction technique. One hundred and seventy episodes of intussusception occurring in the patients of Chiang Mai University Hospital and Siriraj Hospital were included in this study. The success rate of pneumatic reduction was 61% and that of hydrostatic reduction was 44% (P=0.036). Multivariable analysis and adjusting of the factors by propensity scores were performed; the success rate of pneumatic reduction was 1.48 times more than that of hydrostatic reduction (P=0.036, 95% confidence interval [CI] =1.03-2.13). Both pneumatic and hydrostatic reduction can be performed safely according to the experience of the radiologist or pediatric surgeon and hospital setting. This study showed that pneumatic reduction had a higher success rate than hydrostatic reduction.

  14. Increased tissue oxygenation explains the attenuation of hyperemia upon repetitive pneumatic compression of the lower leg.

    Science.gov (United States)

    Messere, Alessandro; Ceravolo, Gianluca; Franco, Walter; Maffiodo, Daniela; Ferraresi, Carlo; Roatta, Silvestro

    2017-12-01

    The rapid hyperemia evoked by muscle compression is short lived and was recently shown to undergo a rapid decrease even in spite of continuing mechanical stimulation. The present study aims at investigating the mechanisms underlying this attenuation, which include local metabolic mechanisms, desensitization of mechanosensitive pathways, and reduced efficacy of the muscle pump. In 10 healthy subjects, short sequences of mechanical compressions ( n = 3-6; 150 mmHg) of the lower leg were delivered at different interstimulus intervals (ranging from 20 to 160 s) through a customized pneumatic device. Hemodynamic monitoring included near-infrared spectroscopy, detecting tissue oxygenation and blood volume in calf muscles, and simultaneous echo-Doppler measurement of arterial (superficial femoral artery) and venous (femoral vein) blood flow. The results indicate that 1 ) a long-lasting (>100 s) increase in local tissue oxygenation follows compression-induced hyperemia, 2 ) compression-induced hyperemia exhibits different patterns of attenuation depending on the interstimulus interval, 3 ) the amplitude of the hyperemia is not correlated with the amount of blood volume displaced by the compression, and 4 ) the extent of attenuation negatively correlates with tissue oxygenation ( r  = -0,78, P < 0.05). Increased tissue oxygenation appears to be the key factor for the attenuation of hyperemia upon repetitive compressive stimulation. Tissue oxygenation monitoring is suggested as a useful integration in medical treatments aimed at improving local circulation by repetitive tissue compression. NEW & NOTEWORTHY This study shows that 1 ) the hyperemia induced by muscle compression produces a long-lasting increase in tissue oxygenation, 2 ) the hyperemia produced by subsequent muscle compressions exhibits different patterns of attenuation at different interstimulus intervals, and 3 ) the extent of attenuation of the compression-induced hyperemia is proportional to the level of

  15. Feasibility Analysis of a Type of Soft Firing Technology with Pneumatic Transmission

    Institute of Scientific and Technical Information of China (English)

    YANG Jun-rong; MI Liang-chuan; ZHAO Hua

    2006-01-01

    Aimed at solving the conflict between the requirements of reducing gun recoil and increasing muzzle velocity, a new type of soft firing technology with pneumatic transmission is put forward. By mathematical model and instance simulation, the feasibility analysis of this technique is made. The result shows that the soft firing technology with pneumatic transmission can reduce the maximum pressure on the breechblock by 27 % and increase the muzzle velocity by 20 %. The proposed new approach has the significance to the compatibility of power and flexibility.

  16. Study of the effect of temperature on the positioning accuracy of the pneumatic muscles

    Science.gov (United States)

    Laski, Pawel Andrzej; Blasiak, Slawomir; Takosoglu, Jakub Emanuel; Pietrala, Dawid Sebastian; Bracha, Gabriel Filip; Zwierzchowski, Jaroslaw; Nowakowski, Lukasz; Borkowski, Krzysztof; Blasiak, Malgorzata

    The article concerns experimental studies of the effect of temperature on the positioning accuracy of pneumatic muscles. It presents results of experimental studies in the form of thermal images from thermal imaging camera. Pneumatic artificial muscles have unique operational characteristics and because of that they are used in industrial production processes, where classic drives do not work. During operation of muscles with large frequencies above 60 Hz, one can observe a significant increase in temperatures on the bladder surface. The article concerns a study aimed at the determination of the maximum temperature which can be achieved and whether it affects the accuracy of their positioning.

  17. [Development of an automatic pneumatic tourniquet system that determines pressures in synchrony with systolic blood pressure].

    Science.gov (United States)

    Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong

    2012-11-01

    The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.

  18. On-line automatic detection of wood pellets in pneumatically conveyed wood dust flow

    Science.gov (United States)

    Sun, Duo; Yan, Yong; Carter, Robert M.; Gao, Lingjun; Qian, Xiangchen; Lu, Gang

    2014-04-01

    This paper presents a piezoelectric transducer based system for on-line automatic detection of wood pellets in wood dust flow in pneumatic conveying pipelines. The piezoelectric transducer senses non-intrusively the collisions between wood pellets and the pipe wall. Wavelet-based denoising is adopted to eliminate environmental noise and recover the collision events. Then the wood pellets are identified by sliding a time window through the denoised signal with a suitable threshold. Experiments were carried out on a laboratory test rig and on an industrial pneumatic conveying pipeline to assess the effectiveness and operability of the system.

  19. Design of a pneumatic system for the development of skills among aeronautics maintenance technology students

    OpenAIRE

    Calderón Pérez, Jorge Luis; Cruz Rico, Oliver; Ospina Martínez, Darwin

    2016-01-01

    Introduction: This article is the result of the “Design and installation of a pneumatic system for Aeronautics Maintenance Technology students’ instruction (TMA)”. The research was conducted during 2014 and 2015 by the Police Aviation School research group (esavi), attached to the National Directorate of Schools (DINAE). Methodology: design and construction of a lab with a pneumatic system for handling aviation materials and structures by the Aeronautics Maintenance Technology students. The p...

  20. Development of Pipe Holding Mechanism for Pipe Inspection Robot Using Flexible Pneumatic Cylinder

    Directory of Open Access Journals (Sweden)

    Choi Kyujun

    2016-01-01

    Full Text Available A pipe inspection robot is useful to reduce the inspection cost. In the previous study, a novel pipe inspection robot using a flexible pneumatic cylinder that can move forward along to the pipe by changing the robot’s body naturally was proposed and tested. In this paper, to improve its mobility for a corner of a pipe, the thin pipe holding mechanism using pneumatic bellows was proposed and tested. As a result of its driving test, the holding performance of the mechanism was confirmed.

  1. Operating a pneumatic-mechanical flotation machine for coal-slurry flotation

    Energy Technology Data Exchange (ETDEWEB)

    Shmaenok, N M; Bedran, N G; Konstantinov, V K; Kochetkov, Yu I; Sysoev, V S

    1976-01-01

    The FPM-GMO-1.6 pneumatic-mechanical flotation machine is easy to operate and regulate and maintains a high throughput at a low energy consumption. The flotation process is stable, the quality of the concentrate and tailings satisfactory, and the selectivity of separation high. The machine cannot handle coal slurries at higher throughputs because the rate of froth removal is too low across the entire flotation front. Experience on the pneumatic-mechanical flotation machine at the ''Kolosnikovskaya'' Central Washery indicates that a similar machine should be developed for a throughput of 1000 m/sup 3//hr.

  2. Comparison of efficacy combination of inhaled phormoterol / budesonide turbuhaler vs. combination of nebulized salbutamol / ipratropium bromide on moderate asthma acute exacerbation in Persahabatan Hospital

    Directory of Open Access Journals (Sweden)

    Zulkarnain Barasila

    2006-03-01

    Full Text Available The aim of this study was to compare efficacy combination of phormoterol/budesonide turbuhaler vs. salbutamol/ipratropium bromide nebulization. Main therapy for acute asthma is inhaled short acting β2-agonist. Asthma patients are using two drugs, controller and reliever. Recently there is device-containing combination of long-acting β2-agonist with rapid onset and corticosteroid. This combination can act as reliever and controller. An opened randomized clinical trial of 76 patients between the ages of 12 and 60 years presenting to Persahabatan Hospital with asthma score between 8-12 participated in this study. After initial evaluation, patients were divided into two groups. Thirty-eight patients were administered combination of formoterol/budesonide 4.5/160 µg via turbuhaler (T-group every 20 minutes, total of three doses, and another 38 of salbutamol/ipratropium bromide 2.5/0.25 mg via nebulizer (N-group also with the same manner. There were no statistical difference in sex, mean age, high, weight, initial PEFR, and asthma score between two groups. The significant increased of PEFR and decreased of asthma score were observed in both groups. However, there were no significant difference of PEFR and asthma score between the two groups within every time-interval. Adverse events were mild including hoarseness, tremor and palpitation. Of T-group, 1 subject was suffered from 3 adverse events simultaneously (hoarseness, tremor and palpitation, 5 subjects were only tremor. Of N-group, all 6 subjects were only suffered from tremor. A combination of formoterol/budesonide turbuhaler and a combination of nebulized salbutamol/ipratropium bromide are clinically equivalent for treatment moderate acute asthma. However, nebulized salbutamol/ipratropium bromide had less adverse effects. (Med J Indones 2006; 15:34-42Keywords: phormoterol, budesonide, salbutamol, ipratropium bromide, acute asthma

  3. Lung diseases caused by /sup 60/Co irradiation combined by nebulizer therapy with Dexa-Scheroson after the operation of cancer of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Saima, S; Oshiro, H; Yamamoto, Y; Naka, K; Asahara, T [Hiroshima Prefectural Hospital, Hiroshima (Japan)

    1975-11-01

    In 29 cases in which the operation had been carried out for cancer of the breast, nebulizer therapy with Dexa-Scheroson was performed 30 minutes before /sup 60/Co irradiation. Radiation pneumonitis was observed in 17.2% of them, but there was no combination of pulmonary fibrosis. Thus, this method showed no serious side effects, and seemed effective for preventing the roentgenographic changes of the lung caused by /sup 60/Co irradiation.

  4. Modulation of sugar cane bagasse pneumatic drying in a vortex; Modelación del secado neumático vortiginoso del bagazo de la caña de azúcar

    Energy Technology Data Exchange (ETDEWEB)

    Bombino Matos, Eugenio F.; Roca Alarcón, Guillermo A. [Universidad de Oriente. Facultad de Ingeniería Mecánica. Santiago de Cuba (Cuba); Marín Morán, Jorge E. [Universidad de Oriente. Facultad de Ciencias Naturales. Santiago de Cuba (Cuba)

    2013-07-01

    Taking in account the studies carried out about the vortex movement of bagasse particles, the study of pneumatic drying of this important biomass was carried out considering the heat and mass transfer. The drying process was modeled through the fundamentals equations which describe the kinetic of it and the obtained results were compared with results reported in the specialized literature on drying measurements in others kinds of bagasse pneumatics dryers under the same conditions of operation. This modulation permitted to made simulations of this process which produced acceptable results about the decrease humidity values of bagasse and it will permit to continue in the development of next studies about this topic because it is evident that it is possible to reduce bagasse dryer dimensions. (author)

  5. Nebulized fentanyl vs intravenous morphine for ED patients with acute abdominal pain: a randomized double-blinded, placebo-controlled clinical trial.

    Science.gov (United States)

    Deaton, Travis; Auten, Jonathan D; Darracq, Michael A

    2015-06-01

    Patients with acute abdominal pain commonly present to emergency departments. The safe and effective relief of discomfort is a concern to patients and physicians. Intravenous opioids are the traditional method used to provide pain relief in this setting, but intravenous access is time consuming and not always achievable. Alternative methods of pain control may therefore be necessary for the acute management of painful conditions without adding to the overall physical or psychological discomfort. The purpose of this study was to evaluate the feasibility of nebulized fentanyl (NF) in the alleviation of acute and undifferentiated abdominal pain. We also sought to compare NF with intravenous morphine (IVM) and to assess patient and provider satisfaction with NF. Nebulized fentanyl (2 μg/kg) was compared to IVM (0.1 mg/kg) at 10, 20, 30, and 40 minutes; and patient and physician satisfaction was recorded. The NF group experienced more rapid pain relief and more sustained and clinically significant pain relief over the 40-minute study interval. There were no adverse effects noted in the NF group. Both patient and physician satisfaction scores were higher in the NF group. Fentanyl citrate at a dose of 2 μg/kg through a breath-actuated nebulizer appears to be a feasible and safe alternative to IVM (0.1 mg/kg) in the treatment of acute abdominal pain. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Rehydrated sterically stabilized phospholipid nanomicelles of budesonide for nebulization: physicochemical characterization and in vitro, in vivo evaluations

    Directory of Open Access Journals (Sweden)

    Sahib MN

    2011-10-01

    Full Text Available Mohanad Naji Sahib, Yusrida Darwis, Kok Khiang Peh, Shaymaa Abdalwahed Abdulameer, Yvonne Tze Fung TanSchool of Pharmaceutical Sciences, Universiti Sains Malaysia, Penang, MalaysiaBackground: Inhaled corticosteroids provide unique systems for local treatment of asthma or chronic obstructive pulmonary disease. However, the use of poorly soluble drugs for nebulization has been inadequate, and many patients rely on large doses to achieve optimal control of their disease. Theoretically, nanotechnology with a sustained-release formulation may provide a favorable therapeutic index. The aim of this study was to determine the feasibility of using sterically stabilized phospholipid nanomicelles of budesonide for pulmonary delivery via nebulization.Methods: PEG5000-DSPE polymeric micelles containing budesonide (BUD-SSMs were prepared by the coprecipitation and reconstitution method, and the physicochemical and pharmacodynamic characteristics of BUD-SSMs were investigated.Results: The optimal concentration of solubilized budesonide at 5 mM PEG5000-DSPE was 605.71 ± 6.38 µg/mL, with a single-sized peak population determined by photon correlation spectroscopy and a particle size distribution of 21.51 ± 1.5 nm. The zeta potential of BUD-SSMs was -28.43 ± 1.98 mV. The percent entrapment efficiency, percent yield, and percent drug loading of the lyophilized formulations were 100.13% ± 1.09%, 97.98% ± 1.95%, and 2.01% ± 0.02%, respectively. Budesonide was found to be amorphous by differential scanning calorimetry, and had no chemical interaction with PEGylated polymer according to Fourier transform infrared spectroscopy. Transmission electron microscopic images of BUD-SSMs revealed spherical nanoparticles. BUD-SSMs exhibited prolonged dissolution behavior compared with Pulmicort Respules® (P , 0.05. Aerodynamic characteristics indicated significantly higher deposition in the lungs compared with Pulmicort Respules®. The mass median aerodynamic, geometric

  7. Structure, optical and electrical properties of indium tin oxide ultra thin films prepared by jet nebulizer spray pyrolysis technique

    Directory of Open Access Journals (Sweden)

    M. Thirumoorthi

    2016-03-01

    Full Text Available Indium tin oxide (ITO thin films have been prepared by jet nebulizer spray pyrolysis technique for different Sn concentrations on glass substrates. X-ray diffraction patterns reveal that all the films are polycrystalline of cubic structure with preferentially oriented along (222 plane. SEM images show that films exhibit uniform surface morphology with well-defined spherical particles. The EDX spectrum confirms the presence of In, Sn and O elements in prepared films. AFM result indicates that the surface roughness of the films is reduced as Sn doping. The optical transmittance of ITO thin films is improved from 77% to 87% in visible region and optical band gap is increased from 3.59 to 4.07 eV. Photoluminescence spectra show mainly three emissions peaks (UV, blue and green and a shift observed in UV emission peak. The presence of functional groups and chemical bonding was analyzed by FTIR. Hall effect measurements show prepared films having n-type conductivity with low resistivity (3.9 × 10−4 Ω-cm and high carrier concentrations (6.1 × 1020 cm−3.

  8. Effect of precursor concentration on physical properties of nebulized spray deposited In2S3 thin films

    Directory of Open Access Journals (Sweden)

    J. Raj Mohamed

    2016-09-01

    Full Text Available The present work investigates the effect of precursor concentration (mc on the structural, optical, morphological and electrical conductivity properties of In2S3 thin films grown on amorphous glass substrates by nebulized spray pyrolysis (NSP technique. The mixed phase of cubic and tetragonal structure of In2S3 thin films at higher concentration has been observed by X-ray diffraction pattern. The reduced strain by increasing the precursor concentration increased the average crystallite from 17.8 to 28.9 nm. The energy dispersive analysis by X-ray (EDAX studies confirmed the presence of In and S. The transmittance, optical direct band gap energy, Urbach energy and skin depth of In2S3 films have been analyzed by optical absorption spectra. The better conductivity and mobility noticed at mc = 0.15 M are explained by carrier concentration and crystallite. Better optical and electrical conductivity behaviour of In2S3 thin film sample proposes for effective solar cell fabrication.

  9. Finite-element analysis of some pneumatically-actuated wrist-rehabilitation equipment

    Directory of Open Access Journals (Sweden)

    Filip Ovidiu

    2017-01-01

    Full Text Available The paper presents some wrist-rehabilitation equipment, actuated by a pneumatic muscle. This one drives, through a rack-pinion mechanism, a Fin Ray-type mechanism, with a view to mobilizing the injured palm. Unlike other rehabilitation equipments, the one presented in this paper, ensures the movement of both palm and fingers.

  10. Complex modeling of technological processes in pneumatic mixers for production of dry construction mixtures

    Science.gov (United States)

    Orekhova, T. N.; Nosov, O. A.; Prokopenko, V. S.; Kachaev, A. E.

    2018-03-01

    The improvement of the design of the pneumatic mixers aimed at the possibility of obtaining homogeneous disperse systems, while the resource and energy saving issues play an important role in the conditions of enterprises that use this type of equipment in their technological chain, is described in the article.

  11. Novel Use of a Pneumatic Compression Device for Haemostasis of Haemodialysis Fistula Access Catheterisation Sites

    Energy Technology Data Exchange (ETDEWEB)

    O’Reilly, Michael K., E-mail: moreilly1@mater.ie; Ryan, David; Sugrue, Gavin; Geoghegan, Tony; Lawler, Leo P.; Farrelly, Cormac T. [Mater Misericordiae University Hospital, Department of Interventional Radiology (Ireland)

    2016-12-15

    PurposeTransradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device.Materials and MethodsA retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complications were recorded.ResultsTwo diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15–20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded.ConclusionsHaemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.

  12. On the estimation method of compressed air consumption during pneumatic caisson sinking

    OpenAIRE

    平川, 修治; ヒラカワ, シュウジ; Shuji, HIRAKAWA

    1990-01-01

    There are several methods in estimation of compressed air consumption during pneumatic caisson sinking. It is re uired in the estimation of compressed air consumption by the methods under the same conditions. In this paper, it is proposed the methods which is able to estimate accurately the compressed air consumption during pnbumatic caissons sinking at this moment.

  13. Computed tomography in the evaluation of the lower leg oedema treated by intermittent pneumatic compression

    International Nuclear Information System (INIS)

    Airaksinen, O.; Partanen, K.; Kolari, P.J.; Soimakallio, S.

    1990-01-01

    The intermittent pneumatic compression (IPC) therapy has been used in post-traumatic rehabilitation of fractures of crusis, and it has reduced the oedema as measured immediately after the treatment. The purpose of the present study was to assess the amount of oedema, and its distribution with CT in lower leg fracture patients before and after IPC treatment (author). 6 refs. 2 tabs

  14. Present status and prospect of the pneumatics; Kukiatsu gijutsu no ayumi to kongono kenkyu no kadai

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, S. [Waseda University, Tokyo (Japan). School of Science and Engineering

    2000-05-15

    This paper describes course of pneumatic technologies and problems in future researches. Pneumatic systems are inferior to electric and hydraulic systems in terms of efficiency. It is because electric power is converted into fluidized energy by using a compressor, and then converted to mechanical energy by using an actuator. When theses published from 1990 through 1999 are put in order, the research objects are accounted for half by control related technologies, and researches related to elements account for only one third. This paper enumerates assignments to be tackled positively in the future by utilizing compressibility of air in pneumatic systems, and features of high speed drive utilizing the stored energy instantaneously. Application of air pressure to robotics from the demand of the aging society, and pneumatic tools having intelligent functions must be subjected to new contrivances. These will serve for work assistance systems to enable aged people to perform works, and for activating industries including organic agriculture. Tools in this sense may include impact wrench, and others. Furthermore, development of fundamental studies for 'why air pressure?' is demanded strongly, including the viewpoint of LCA in the recycling type society. (NEDO)

  15. Aircraft Fuel, Hydraulic and Pneumatic Systems (Course Outlines), Aviation Mechanics 3 (Air Frame): 9067.01.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This document presents an outline for a 135-hour course designed to familiarize the student with the operation, inspection, and repair of aircraft fuel, hydraulic, and pneumatic systems. It is designed to help the trainee master the knowledge and skills necessary to become an aviation airframe mechanic. The aviation airframe maintenance technician…

  16. Integrated DEM-CFD modeling of the contact charging of pneumatically conveyed powders

    NARCIS (Netherlands)

    Korevaar, M.W.; Padding, J.T.; Hoef, van der M.A.; Kuipers, J.A.M.

    2014-01-01

    A model is proposed that incorporates contact charging (also known as triboelectric charging) of pneumatically conveyed powders in a DEM–CFD framework, which accounts for the electrostatic interactions, both between particles and between the particles and conducting walls. The simulation results

  17. Integrated DEM–CFD modeling of the contact charging of pneumatically conveyed powders

    NARCIS (Netherlands)

    Korevaar, M.W.; Padding, J.T.; van der Hoef, Martin Anton; Kuipers, J.A.M.

    2014-01-01

    A model is proposed that incorporates contact charging (also known as triboelectric charging) of pneumatically conveyed powders in a DEM–CFD framework, which accounts for the electrostatic interactions, both between particles and between the particles and conducting walls. The simulation results

  18. Pneumatically-powered hand tool used for cutting bolts during bone-fixing in surgery

    NARCIS (Netherlands)

    Cool, J.C.; Rijnsaardt, K.A.

    1996-01-01

    Abstract of NL 1000849 (C2) The tool has at least one pneumatic motor (1a, 1b), transmission (2) and regulator. The motor(s) can be of the piston and cylinder type producing reciprocating motion or of the rotary type. The tool is powered by a commercially-available gas cylinder containing 16g of CO2

  19. STUDY OF ELABORATION OF CONSTRUCTION CRANKSHAFT PISTON OF AUTOMOBILE PNEUMATIC ENGINE

    Directory of Open Access Journals (Sweden)

    Voronkov, А.

    2013-01-01

    Full Text Available Expound are the results of study of elaration of construction of crankshaft 4-cylinder V-evocative piston pneumatic engine, which is made by conversion of serial internal-combustion engine 4Ч 7,6x6,6.

  20. Design of a Soft Robot with Multiple Motion Patterns Using Soft Pneumatic Actuators

    Science.gov (United States)

    Miao, Yu; Dong, Wei; Du, Zhijiang

    2017-11-01

    Soft robots are made of soft materials and have good flexibility and infinite degrees of freedom in theory. These properties enable soft robots to work in narrow space and adapt to external environment. In this paper, a 2-DOF soft pneumatic actuator is introduced, with two chambers symmetrically distributed on both sides and a jamming cylinder along the axis. Fibers are used to constrain the expansion of the soft actuator. Experiments are carried out to test the performance of the soft actuator, including bending and elongation characteristics. A soft robot is designed and fabricated by connecting four soft pneumatic actuators to a 3D-printed board. The soft robotic system is then established. The pneumatic circuit is built by pumps and solenoid valves. The control system is based on the control board Arduino Mega 2560. Relay modules are used to control valves and pressure sensors are used to measure pressure in the pneumatic circuit. Experiments are conducted to test the performance of the proposed soft robot.

  1. Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.

    Science.gov (United States)

    Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J

    2017-07-01

    The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.

  2. The pneumatic syringe: a simple apparatus for self-administration of drugs by rats.

    Science.gov (United States)

    Weeks, J R

    1977-12-01

    Drug solution is delivered by a syringe operated by a pneumatic cylinder. Recommended delivery volumes are from 10 to 200 microliter. A solid-state control unit is described which can operate two syringes (drug injection and flush), has outputs for recording responses and injections, and can be programmed to provide several schedules of reinforcement. All components are readily commercially available.

  3. Design Methodology of Camshaft Driven Charge Valves for Pneumatic Engine Starts

    Directory of Open Access Journals (Sweden)

    Moser Michael M.

    2015-01-01

    Full Text Available Idling losses constitute a significant amount of the fuel consumption of internal combustion engines. Therefore, shutting down the engine during idling phases can improve its overall efficiency. For driver acceptance a fast restart of the engine must be guaranteed. A fast engine start can be performed using a powerful electric starter and an appropriate battery which are found in hybrid electric vehicles, for example. However, these devices involve additional cost and weight. An alternative method is to use a tank with pressurized air that can be injected directly into the cylinders to start the engine pneumatically. In this paper, pneumatic engine starts using camshaft driven charge valves are discussed. A general methodology for an air-optimal charge valve design is presented which can deal with various requirements. The proposed design methodology is based on a process model representing pneumatic engine operation. A design example for a two-cylinder engine is shown, and the resulting optimized pneumatic start is experimentally verified on a test bench engine. The engine’s idling speed of 1200 rpm can be reached within 350 ms for an initial pressure in the air tank of 10 bar. A detailed system analysis highlights the characteristics of the optimal design found.

  4. Assessment of Uinta Basin Oil and Natural Gas Well Pad Pneumatic Controller Emissions

    Science.gov (United States)

    In the fall of 2016, a field study was conducted in the Uinta Basin Utah to improve information on oil and natural gas well pad pneumatic controllers (PCs) and emission measurement methods. A total of 80 PC systems at five oil sites (supporting six wells) and three gas sites (sup...

  5. [Study of the degree of pneumatization of the viscerocranium in man and pongidae].

    Science.gov (United States)

    Koppe, T; Schumacher, K U

    1992-12-01

    The volumes of the paranasal sinuses of 41 adult skulls of humans, gorillas, chimpanzees and orangutans, were examined with use of a Computertomograph type SOMATOM DR. The percentage distribution of the volumes of the different paranasal sinuses showed that the maxillary sinus always had the greatest volume. The maxillary sinus of the humans showed the smallest volume percentage in comparison with the pongids. The typical differences between humans and pongids were observed in the ethmoidal cells and the sphenoidal sinus. The ethmoidal cells of the gorilla and the orangutan have to be defined as rudimentary. Those of the humans come to more than 20% of the total volume of the paranasal sinuses of all hominoids. Differing from the humans, the sphenoidal sinus of the pongids pneumatizes almost the whole sphenoid bone. This volume percentage of the pongids is twice as high as that of the humans. In addition, an index was calculated from the volume of the facial skeleton volume and the total volume of the paranasal sinuses and defined as the degree of pneumatization. We found that the gorilla has the highest degree of pneumatization followed by the chimpanzee, the orangutan, and the humans. The lowest degree of pneumatization of the humans may be related to the reduction of the jaws.

  6. Pulse width modulation based pneumatic frequency tuner of the superconducting resonators at IUAC

    International Nuclear Information System (INIS)

    Pandey, A.; Suman, S.K.; Mathuria, D.S.

    2015-01-01

    The existing phase locking scheme of the quarter wave resonators (QWR) used in superconducting linear accelerator (LINAC) of IUAC consists of a fast time (electronic) and a slow time (pneumatic) control. Presently, piezo based mechanical tuners are being used to phase lock the resonators installed in the second and third accelerating modules of LINAC. However, due to space constraint, the piezo tuner can't be implemented on the resonators of the first accelerating module. Therefore, helium gas operated mechanical tuners are being used to phase lock the resonators against the master oscillator (MO) frequency. The present pneumatic frequency tuner has limitations of non-linearity, hysteresis and slow response time. To overcome these problems and to improve the dynamics of the existing tuner, a new pulse width modulation (PWM) based pneumatic frequency tuning system was adopted and successfully tested. After successful test, the PWM based pneumatic frequency tuner was installed in four QWR of the first accelerating module of LINAC. During beam run the PWM based frequency tuner performed well and the cavities could be phase locked at comparatively higher accelerating fields. A comparison of the existing tuning mechanism and the PWM based tuning system along with the test results will be presented in the paper. (author)

  7. Variability in sphenoid sinus pneumatization and its impact upon reduction of complications following sellar region surgeries

    Directory of Open Access Journals (Sweden)

    Tarek H. ELKammash

    2014-09-01

    Conclusion: Pre-intervention assessment of sphenoid sinus pneumatization is mandatory in approaching the sella and skull base structures either via the nose or open skull base surgery to avoid injury of the nearby structures and reduce the possibility of CSF leakage.

  8. Asymmetric Fuzzy Control of a Positive and Negative Pneumatic Pressure Servo System

    Science.gov (United States)

    Yang, Gang; Du, Jing-Min; Fu, Xiao-Yun; Li, Bao-Ren

    2017-11-01

    The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mechanisms employing the error and change in error of the controlled variable as input parameters, the current chamber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the proposed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consistent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.

  9. Education for hydraulics and pneumatics in Nihon University; Nihon Daigaku ni okeru yukuatsu kyoiku

    Energy Technology Data Exchange (ETDEWEB)

    Ouchi, M. [Nihon Univ., Chiba (Japan). Coll. of Industrial Technology

    2000-03-15

    Described herein is education of hydraulics and pneumatics in Nihon University. Department of Mechanical Engineering of Faculty of Production Engineering has been holding up the educational aims of bringing up engineers and researchers who have ability and intelligence to cope with internationalization and contribute to society, and of bringing about creativity, among others. Control equipment is an optional subject for the sophomore class in the second semester, and is centered by mechatronics, including hydraulic and pneumatic control systems and equipment. The related subjects include fluid dynamics, control engineering, system controlling, hydraulic machines, robotics and automobile engineering. The drill course includes disassembling and assembling gear pumps, drills on pneumatic devices, system behavior and mechatronics, experiments on fan and hydraulic control circuits and on servo mechanisms, and machinery designs and drawings. Seminars are led by full-time or part-time lecturers for the themes related to hydraulic power. Many students are interested in hydraulic and pneumatic themes for their graduation theses, because of their relations with control, environments, energy saving and so on. We are now in the age of composite technologies, and hydraulic power basics are prerequisite for engineers, and important for education of students. (NEDO)

  10. Position control of a single pneumatic artificial muscle with hysteresis compensation based on modified Prandtl-Ishlinskii model.

    Science.gov (United States)

    Zang, Xizhe; Liu, Yixiang; Heng, Shuai; Lin, Zhenkun; Zhao, Jie

    2017-01-01

    High-performance position control of pneumatic artificial muscles is limited by their inherent nonlinearity and hysteresis. This study aims to model the length/pressure hysteresis of a single pneumatic artificial muscle and to realize its accurate position tracking control with forward hysteresis compensation. The classical Prandtl-Ishlinskii model is widely used in hysteresis modelling and compensation. But it is only effective for symmetric hysteresis. Therefore, a modified Prandtl-Ishlinskii model is built to characterize the asymmetric length/pressure hysteresis of a single pneumatic artificial muscle, by replacing the classical play operators with two more flexible elementary operators to independently describe the ascending branch and descending branch of hysteresis loops. On the basis, a position tracking controller, which is composed of cascade forward hysteresis compensation and simple proportional pressure controller, is designed for the pneumatic artificial muscle. Experiment results show that the MPI model can reproduce the length/pressure hysteresis of the pneumatic artificial muscle, and the proposed controller for the pneumatic artificial muscle can track the reference position signals with high accuracy. By modelling the length/pressure hysteresis with the modified Prandtl-Ishlinskii model and using its inversion for compensation, precise position control of a single pneumatic artificial muscle is achieved.

  11. Electro pneumatic trainer embedded with programmable integrated circuit (PIC) microcontroller and graphical user interface platform for aviation industries training purposes

    Science.gov (United States)

    Burhan, I.; Azman, A. A.; Othman, R.

    2016-10-01

    An electro pneumatic trainer embedded with programmable integrated circuit (PIC) microcontroller and Visual Basic (VB) platform is fabricated as a supporting tool to existing teaching and learning process, and to achieve the objectives and learning outcomes towards enhancing the student's knowledge and hands-on skill, especially in electro pneumatic devices. The existing learning process for electro pneumatic courses conducted in the classroom does not emphasize on simulation and complex practical aspects. VB is used as the platform for graphical user interface (GUI) while PIC as the interface circuit between the GUI and hardware of electro pneumatic apparatus. Fabrication of electro pneumatic trainer interfacing between PIC and VB has been designed and improved by involving multiple types of electro pneumatic apparatus such as linear drive, air motor, semi rotary motor, double acting cylinder and single acting cylinder. Newly fabricated electro pneumatic trainer microcontroller interface can be programmed and re-programmed for numerous combination of tasks. Based on the survey to 175 student participants, 97% of the respondents agreed that the newly fabricated trainer is user friendly, safe and attractive, and 96.8% of the respondents strongly agreed that there is improvement in knowledge development and also hands-on skill in their learning process. Furthermore, the Lab Practical Evaluation record has indicated that the respondents have improved their academic performance (hands-on skills) by an average of 23.5%.

  12. Prevalence and characteristics of pneumatized articular tubercle: First large series in Iranian people

    Energy Technology Data Exchange (ETDEWEB)

    Shokri, Abbas; Noruzi-Gangachin, Marruf [Dept. of Oral and Maxillofacial Radiology, Dental School, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of); Baharvand, Maryam; Mortazavi, Hamed [Dept. of Oral and Maxillofacial Medicine, Dental School, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2013-12-15

    This study was performed to determine the prevalence and characteristics of pneumatized articular tubercle or eminence among a defined group of Iranian people. Digital panoramic radiographs of 1694 patients in the Department of Oral and Maxillofacial Radiology, Hamadan Dental School, Iran were evaluated retrospectively to detect the above lesion. Finally, 1563 radiographs were selected according to inclusion criteria. Then, a review was done of 10 large case series found using a MEDLINE search of the literature. Chi-squared test was used to analyze the differences in variables such as age, gender, laterality, and locularity in our case series. The average age of our samples was 32.6±7.63 years. Pneumatized articular tubercle was found in 98 cases, representing a prevalence of 6.2% with a mean age of 22.8±7.9 and a range of 8 to 60 years. Sixty-four (65.3%) pneumatized articular tubercles were unilateral, with 30 lesions on the right and 34 on the left side. Bilateral lesions were found in 34 (34.7%) patients. 52 (53.06%) of the pneumatized articular tubercles were of the unilocular type and 46 (46.94%) were multilocular. The results showed no statistically significant differences regarding age (p=0.454), gender (p=0.634), laterality (p=0.252), or locularity (p=0.807) among the samples. Among ten large case series from other countries, the prevalence of pneumatized articular tubercle (6.2%) in Iranian patients was higher than that of all eight of the case series that used the same detection method as the present study of panoramic radiography.

  13. Influence of Isoinertial-Pneumatic Mixed Resistances on Force-Velocity Relationship.

    Science.gov (United States)

    Avrillon, Simon; Jidovtseff, Boris; Hug, François; Guilhem, Gaël

    2017-03-01

    Muscle strengthening is commonly based on the use of isoinertial loading, whereas variable resistances such as pneumatic loading may be implemented to optimize training stimulus. The purpose of the current study was to determine the effect of the ratio between pneumatic and isoinertial resistance on the force-velocity relationship during ballistic movements. A total of 15 participants performed 2 concentric repetitions of ballistic bench-press movements with intention to throw the bar at 30%, 45%, 60%, 75%, and 90% of the maximal concentric repetition with 5 resistance ratios including 100%, 75%, 50%, 25%, or 0% of pneumatic resistance, the additional load being isoinertial. Force-, velocity-, and power-time patterns were assessed and averaged over the concentric phase to determine the force-velocity and power-velocity relationships for each resistance ratio. Each 25% increase in the pneumatic part in the resistance ratio elicited higher movement velocity (+0.11 ± 0.03 m/s from 0% to 80% of the concentric phase) associated with lower force levels (-43.6 ± 15.2 N). Increased isoinertial part in the resistance ratio resulted in higher velocity toward the end of the movement (+0.23 ± 0.01 m/s from 90% to 100%). The findings show that the resistance ratio could be modulated to develop the acceleration phase and force toward the end of the concentric phase (pneumatic-oriented resistance). Inversely, isoinertial-oriented resistance should be used to develop maximal force and maximal power. Resistance modality could, therefore, be considered an innovative variable to modulate the training stimulus according to athletic purposes.

  14. Additional Development and Systems Analyses of Pneumatic Technology for High Speed Civil Transport Aircraft

    Science.gov (United States)

    Englar, Robert J.; Willie, F. Scott; Lee, Warren J.

    1999-01-01

    In the Task I portion of this NASA research grant, configuration development and experimental investigations have been conducted on a series of pneumatic high-lift and control surface devices applied to a generic High Speed Civil Transport (HSCT) model configuration to determine their potential for improved aerodynamic performance, plus stability and control of higher performance aircraft. These investigations were intended to optimize pneumatic lift and drag performance; provide adequate control and longitudinal stability; reduce separation flowfields at high angle of attack; increase takeoff/climbout lift-to-drag ratios; and reduce system complexity and weight. Experimental aerodynamic evaluations were performed on a semi-span HSCT generic model with improved fuselage fineness ratio and with interchangeable plain flaps, blown flaps, pneumatic Circulation Control Wing (CCW) high-lift configurations, plain and blown canards, a novel Circulation Control (CC) cylinder blown canard, and a clean cruise wing for reference. Conventional tail power was also investigated for longitudinal trim capability. Also evaluated was unsteady pulsed blowing of the wing high-lift system to determine if reduced pulsed mass flow rates and blowing requirements could be made to yield the same lift as that resulting from steady-state blowing. Depending on the pulsing frequency applied, reduced mass flow rates were indeed found able to provide lift augmentation at lesser blowing values than for the steady conditions. Significant improvements in the aerodynamic characteristics leading to improved performance and stability/control were identified, and the various components were compared to evaluate the pneumatic potential of each. Aerodynamic results were provided to the Georgia Tech Aerospace System Design Lab. to conduct the companion system analyses and feasibility study (Task 2) of theses concepts applied to an operational advanced HSCT aircraft. Results and conclusions from these

  15. Pneumatic transport system development: residuals and releases program at Westinghouse Cheswick site

    International Nuclear Information System (INIS)

    Larouere, P.J.; Shoulders, J.L.

    1979-01-01

    Plutonium oxide and uranium oxide powders are processed within glove boxes or within confinement systems during the fabrication of mixed oxide (MOX) pellets for recycle fuel. The release of these powders to the glove box or to the confinement results in some airborne material that is deposited in the enclosure or is carried in the air streams to the effluent air filtration system. Release tests on simulated leaks in pneumatic transport equipment and release tests on simulated failures with powder blending equipment were conducted. A task to develop pneumatic transport for the movement of powders within an MOX fabrication plant has been underway at the Westinghouse Research Laboratories. While testing and evaluating selected pneumatic transport components on a full scale were in progress, it was deemed necessary that final verification of the technology would have to be performed with plutonium-bearing powders because of the marked differences in certain properties of plutonium from those of uranium oxides. A smaller was designed and constructed for the planned installation in glove boxes at the Westinghouse Plutonium Fuel Development Laboratory. However, prior to use with plutonium it was agreed that this system be set up and tested with uranium oxide powder. The test program conducted at the Westinghouse Cheswick site was divided into two major parts. The first of these examined the residuals left as a result of the pneumatic transport of nuclear fuel powders and verified the operability of this one-third scale system. The second part of the program studied the amount of powder released to the air when off-standard process procedures or maintenance operations were conducted on the pneumatic transport system. Air samplers located within the walk-in box housing the transport loop were used to measure the solids concentration in the air. From this information, the total amount of airborne powder was determined

  16. Modelling of pneumatic muscle actuator using Hill's model with different approximations of static characteristics of artificial muscle

    Directory of Open Access Journals (Sweden)

    Piteľ Ján

    2016-01-01

    Full Text Available For modelling and simulation of pneumatic muscle actuators the mathematical dependence of the muscle force on the muscle contraction at different pressures in the muscles is necessary to know. For this purpose the static characteristics of the pneumatic artificial muscle type FESTO MAS-20-250N used in the experiments were approximated. In the paper there are shown some simulation results of the pneumatic muscle actuator dynamics using modified Hill's muscle model, in which four different approximations of static characteristics of artificial muscle were used.

  17. APPLICATIONS OF PNEUMATIC MUSCLES DEVELOPED AT THE FESTO REGIONAL RESEARCH AND TRAINING CENTRE OF BRAŞOV

    Directory of Open Access Journals (Sweden)

    Tudor DEACONESCU

    2013-05-01

    Full Text Available Compressed air is one of the most important sources of energy in industry, pneumatic actuations tending to hold an increasing share in the conception of modern industrial systems. At present, due to the development of new pneumatic components and systems assemblies of high complexity can be achieved, many of them with applicability in robotics. Such a component is the pneumatic muscle, increasingly deployed in actuation systems, particularly in the field of industrial robots. The paper presents some of the results of research conducted at the Festo Regional Research and Training Centre (FRRTC at Transilvania University of Braşov.

  18. Continuous auditing & continuous monitoring : Continuous value?

    NARCIS (Netherlands)

    van Hillo, Rutger; Weigand, Hans; Espana, S; Ralyte, J; Souveyet, C

    2016-01-01

    Advancements in information technology, new laws and regulations and rapidly changing business conditions have led to a need for more timely and ongoing assurance with effectively working controls. Continuous Auditing (CA) and Continuous Monitoring (CM) technologies have made this possible by

  19. High-throughput continuous cryopump

    International Nuclear Information System (INIS)

    Foster, C.A.

    1986-01-01

    A cryopump with a unique method of regeneration which allows continuous operation at high throughput has been constructed and tested. Deuterium was pumped continuously at a throughput of 30 Torr.L/s at a speed of 2000 L/s and a compression ratio of 200. Argon was pumped at a throughput of 60 Torr.L/s at a speed of 1275 L/s. To produce continuous operation of the pump, a method of regeneration that does not thermally cycle the pump is employed. A small chamber (the ''snail'') passes over the pumping surface and removes the frost from it either by mechanical action with a scraper or by local heating. The material removed is topologically in a secondary vacuum system with low conductance into the primary vacuum; thus, the exhaust can be pumped at pressures up to an effective compression ratio determined by the ratio of the pumping speed to the leakage conductance of the snail. The pump, which is all-metal-sealed and dry and which regenerates every 60 s, would be an ideal system for pumping tritium. Potential fusion applications are for mpmp limiters, for repeating pneumatic pellet injection lines, and for the centrifuge pellet injector spin tank, all of which will require pumping tritium at high throughput. Industrial applications requiring ultraclean pumping of corrosive gases at high throughput, such as the reactive ion etch semiconductor process, may also be feasible

  20. Trace element determination in seawater by ICP-SFMS coupled with a microflow nebulization/desolvation system

    International Nuclear Information System (INIS)

    Turetta, Clara; Cozzi, Giulio; Barbante, Carlo; Capodaglio, Gabriele; Cescon, Paolo

    2004-01-01

    Direct and simultaneous determination of Al, Ag, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Pb, Sb, U, V and Zn in diluted (1:10 v:v) seawater from the Antarctic Ocean and the Venice Lagoon at the ng mL -1 and pg mL -1 level has been performed by using an inductively coupled plasma sector field mass spectrometer (ICP-SFMS). Samples were analysed by using a PFA microflow nebulizer coupled with a desolvation system or a PFA microflow nebulizer coupled with a Teflon spray chamber, respectively. Measurements were carried out at low (LR, m/Δm=300), medium (MR, m/Δm=3,000) and high (HR, m/Δm=7,500) resolutions depending on the studied isotope. To avoid contamination, sample pre-treatment was carried out in a clean laboratory equipped with a Class 100 vertical laminar flow hood. Concentration ranges (minimum-maximum in ng mL -1 ) found in the Antarctic seawater samples (in depth profiles) were: Ag 0.0004-0.0018, As 0.69-1.32, Cd 0.031-0.096, Co 0.018-0.065, Cr 0.18-0.46, Cu 0.04-1.58, Fe 0.13-1.63, Mn 0.02-0.12, Mo 5.97-12.46, Pb 0.007-0.074, Sb 0.033-0.088, U 0.5-1.9, V 0.6-2.5 and Zn 0.16-0.80. Concentration ranges (min-max in ng mL -1 ) found in the Venice Lagoon water samples (temporal profile from a benthic chamber experiment) were: Al 0.24-0.61, Ag 0.007-0.031, As 1.42-2.27, Cd 0.050-0.182, Co 0.440-1.461, Cr 0.15-0.34, Cu 0.81-2.46, Fe 0.25-1.66, Mn 11.6-31.7, Mo 6.50-10.6, Pb 0.047-0.225, Sb 0.240-0.492, U 1.7-3.3, V 1.3-2.8 and Zn 5.20-21.5. The detection limits range between 0.06 pg mL -1 for Ag and U to 15 pg mL -1 for Fe. In order to check the accuracy of the analytical procedure, measurements of the trace elements in a certified reference material (coastal Atlantic seawater, CASS-4-NRCC) were compared with the certified values. In addition, the results from the Antarctic and Venice Lagoon samples were compared with those obtained by using different analytical techniques. (orig.)