WorldWideScience

Sample records for contaminant effects monitoring

  1. Radiation contamination monitors

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Iba, Hiroshi; Sato, Hiroshi

    1999-01-01

    To make sure of no contamination on people, used articles and working uniforms coming out of the radiation controlled area, nuclear power plants are equipped with radioactive contamination monitors. This paper outlines the basic specifications and advantages of our personnel surface contamination monitors to inspect whole-body surface contamination of people coming out, article surface contamination monitors to inspect the surface and inside contamination of used articles brought out, laundry monitors to inspect surface contamination of working uniforms used in the area before and after a wash, and whole-body counters to inspect and measure the internal contamination of a person out of the area. (author)

  2. Radioactive surface contamination monitors

    International Nuclear Information System (INIS)

    Aoyama, Kei; Minagoshi, Atsushi; Hasegawa, Toru

    1994-01-01

    To reduce radiation exposure and prevent contamination from spreading, each nuclear power plant has established a radiation controlled area. People and articles out of the controlled area are checked for the surface contamination of radioactive materials with surface contamination monitors. Fuji Electric has repeatedly improved these monitors on the basis of user's needs. This paper outlines typical of a surface contamination monitor, a personal surface contamination monitor, an article surface contamination monitor and a laundry monitor, and the whole-body counter of an internal contamination monitor. (author)

  3. Application of effective variance method for contamination monitor calibration

    International Nuclear Information System (INIS)

    Goncalez, O.L.; Freitas, I.S.M. de.

    1990-01-01

    In this report, the calibration of a thin window Geiger-Muller type monitor for alpha superficial contamination is presented. The calibration curve is obtained by the method of the least-squares fitting with effective variance. The method and the approach for the calculation are briefly discussed. (author)

  4. Monitoring of transport contamination

    International Nuclear Information System (INIS)

    Turkin, N.F.

    1980-01-01

    Organization of monitoring of transport contamination is considered. A particularly thorough monitoring is recommended to be carried out in loading-unloading operations. The monitoring is performed when leaving loading-unloading site and zone under control and prior to preventive examination, technical service or repair. The method of monitoring of auto transport contamination with high-energy β-emitters by means of a special stand permitting the automation of the monitoring process is described [ru

  5. Monitoring of surface and airborne contamination

    Energy Technology Data Exchange (ETDEWEB)

    Pradeep Kumar, K S [Bhabha Atomic Research Centre, Bombay (India)

    1997-06-01

    Indian nuclear energy programme aims at total safety in all activities involved in the entire fuel cycle for the occupational workers, members of the public and the environment as a whole. Routine radiation monitoring with clearly laid out procedures are followed for ensuring the safety of workers and public. Radiation monitoring carried out for the nuclear installations comprises of process monitoring, monitoring of effluent releases and also of the radiation protection monitoring of the individuals, work place and environment. Regulations like banning of smoking and consumption of food and drink etc. reduces the risk of direct ingestion even if inadvertent spread of contamination takes place. Though limit of transportable surface contamination is prescribed, the health physicists always follow a ``clean on swipe`` philosophy which compensates any error in the measurement of surface contamination. In this paper, the following items are contained: Necessity of contamination monitoring, accuracy required in the calibration of surface contamination monitors, methodology for contamination monitoring, air monitoring, guidelines for unrestricted release of scrap materials, and problems in contamination monitoring. (G.K.)

  6. Contamination monitoring: an overview and its objectives

    International Nuclear Information System (INIS)

    Mangena, S.

    2013-04-01

    The study presents and objectively summarises the aspect of contamination monitoring. This envisages reviewing sources of contamination and evaluating the scientific basis for practice specific courses of action for rehabilitation in a bid to restore pristine conditions wherever possible. The practices considered include nuclear medicine, reprocessing plants, fuel production plants, uranium and thorium mining and milling together with near surface disposal facilities (for radioactive waste). It also deals with monitoring sites contaminated as a consequence of past practices. General issues related to the design and operation of monitoring systems during and in the aftermath of a nuclear or radiological accident are also discussed including monitoring for long lived radionuclides widely dispersed in the environment following an accidental release. Thus the above discourse provides a framework for both quantitative and qualitative measures undertaken to enable effective response in the event of radioactive contamination. (au)

  7. Status on contamination monitoring in China

    Energy Technology Data Exchange (ETDEWEB)

    Quanlu, Gou [China Institute for Radiation Protection, Taiyuan (China)

    1997-06-01

    The air contaminated by radioactive materials in nuclear enterprises and radioactive workplaces and forming radioactive aerosol and the leakage of radioactive materials in operation cause internal exposure damage in workers. It is necessary and important to monitor air and surface contaminations for the health of public and workers, and for protecting environment. At present, many institutes engage in the studies on surface contamination monitoring in China, and the government has formulated the control limits of surface contamination in the Regulations of Radiation Protection. The monitors for surface contamination monitoring are almost home-made. The methods being used often are smear test and placing surface sample test. Scintillation counters, semiconductor detectors and G-M counters have been used for detecting alpha surface contamination. Plastic scintillator meters and thin wall/window G-M counters are used for beta surface contamination. Special detectors have been designed for monitoring low energy nuclides. The status of airborne contamination monitoring in China is reported. As the studies for future, the development of the surface contamination monitor for low energy beta nuclides, especially H-3, the monitoring methods for the special shapes of surfaces, the technology of decontamination and the calibration method and device for on-line radioactive aerosol continuous monitors are taken up. (K.I.)

  8. Development of radioactive surface contamination monitor

    International Nuclear Information System (INIS)

    Hashimoto, Tadao; Hasegawa, Toru; Fukumoto, Keisuke; Ooki, Yasushi

    2008-01-01

    In the radiation facilities such as nuclear power plants, surface contamination of the people accessing or articles conveyed in and out of the radiation controlled areas is detected and monitored by installing contamination monitors at the boundary of controlled areas and uncontrolled areas against the expansion of the radioactive materials to out of the facilities. It is required for the surface contamination of articles to be tightened of control criteria as 'Guidelines for discrimination ways of nonradioactive waste (not classified as radioactive waste) generated from nuclear power plants' (hereinafter referred to as 'the Guideline') was established by the Nuclear and Industrial Safety Agency of the Ministry of Economy, Trade and Industry in August, 2005. It predicts that the control criteria of monitors other than article monitors are also tightened in the future. Fuji electric has been fabricating and delivering surface contamination detecting monitors. Now we are developing the new contamination monitor corresponding to the tightening of the control criteria. 'Large article transfer monitor', 'Clothing monitor' and 'Body surface contamination monitor' are introduced in this article. (author)

  9. Background compensation methodologies for contamination monitoring systems

    International Nuclear Information System (INIS)

    Raman, Anand; Chaudhury, Probal; Pradeepkumar, K.S.

    2014-01-01

    Radiation surveillance program in the various nuclear facilities incorporate contamination monitoring as an important component. Contamination monitoring programs constitute monitoring for alpha and beta contamination of the physical entities associated with the working personnel that include his hands, feet, clothing, shoes as well as the general surface areas in the working environment like floors. All these measurements are fraught with the contribution of the ambient gamma background radiation fields. These inhibit a proper and precise estimation of the contamination concentration being monitored. This paper investigates the efficacy of two methodologies that have been incorporated in two of the contamination monitoring systems developed in the Division. In the first system discussed, a high degree of gamma compensation has been achieved for an uniform exposure of the order of 50 nSv/hr to 100 mSv/hr. In the second system discussed, the degree of gamma compensation achieved is equal to those dictated by the statistical nature of the uncertainties associated with the subtraction of background from the source data. These two methods can be very effectively employed depending on the application requirement. A minimum detection level equivalent to 0.37 Bq/cdm 2 has been achieved in both these cases

  10. Contamination monitoring activities in Kanupp

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, S S [Karachi Nuclear Power Plant (Pakistan)

    1997-06-01

    The Karachi Nuclear Power Plant (Kanupp) is a 137 MWe pressurized heavy water reactor, designed and erected by the Canadian General Electric Company as a turn key project. The plant is in operation since it was commissioned in the year 1972. It is located at the Arabian Sea Coast about 15 miles to the west of Karachi. During its more than two decades of operation, the plant has generated about 8 billion units of electricity with an average life time availability factor of 60%. In Kanupp, radioactive contamination may exit due to the release of fission product, activation products etc., which may somehow escape from its confinement and may contaminate surface or other media such as air, water etc. In this paper, following items are described: main aspects of contamination, status of contamination monitoring, need of contamination monitoring, radiation protection activity, instruments, contamination, current status of contamination survey materials and their disposal, and environmental monitoring. (G.K.)

  11. Automatic personnel contamination monitor

    International Nuclear Information System (INIS)

    Lattin, Kenneth R.

    1978-01-01

    United Nuclear Industries, Inc. (UNI) has developed an automatic personnel contamination monitor (APCM), which uniquely combines the design features of both portal and hand and shoe monitors. In addition, this prototype system also has a number of new features, including: micro computer control and readout, nineteen large area gas flow detectors, real-time background compensation, self-checking for system failures, and card reader identification and control. UNI's experience in operating the Hanford N Reactor, located in Richland, Washington, has shown the necessity of automatically monitoring plant personnel for contamination after they have passed through the procedurally controlled radiation zones. This final check ensures that each radiation zone worker has been properly checked before leaving company controlled boundaries. Investigation of the commercially available portal and hand and shoe monitors indicated that they did not have the sensitivity or sophistication required for UNI's application, therefore, a development program was initiated, resulting in the subject monitor. Field testing shows good sensitivity to personnel contamination with the majority of alarms showing contaminants on clothing, face and head areas. In general, the APCM has sensitivity comparable to portal survey instrumentation. The inherit stand-in, walk-on feature of the APCM not only makes it easy to use, but makes it difficult to bypass. (author)

  12. Hand and foot contamination monitor

    International Nuclear Information System (INIS)

    Jakati, R.K.; Kaptral, R.S.; Ananthkrishnan, T.S.; Pansare, M.G.

    1989-01-01

    In order to make quick measurements of beta and gamma contaminations on hands and feet of personnel working in radioactive environments, hand and foot contamination monitors are widely used. This paper describes such a monitor system designed with Intel 8085 based microcomputer. The monitoring and warning system is designed to perform measurement of activity spread over surface of hands and soles of shoes or feet. Even though the system has many features to aid testing and maintainance operation, it is easy to use for unskilled persons. In order to check the contamination, the person stands on platform and inserts both his hands into detector assemblies thereby actuating the sensing switches. After a preset interval, annunciation of clean or contaminated status is declared by the system. (author)

  13. Calibration of alpha surface contamination monitor

    International Nuclear Information System (INIS)

    Freitas, I.S.M. de; Goncalez, O.L.

    1990-01-01

    In this work, the results, as well as the methodology, of the calibration of an alpha surface contamination monitor are presented. The calibration factors are obtained by least-squares fitting with effective variance. (author)

  14. Biological monitoring of environmental contaminants (plants). Executive summary

    Energy Technology Data Exchange (ETDEWEB)

    Burton, M.A.S.

    1986-01-01

    Knowledge of contaminant concentrations does not necessarily indicate their significance to plant populations and communities within ecosystems. Accumulation within plants facilitates analysis of contaminants which may be present at very low levels in the environment and may show the spatial distribution and changes in the level of contamination with time. Effects on species distribution within plant communities and visible injury to foliage may also be related to contamination. Species can be selected appropriate to the area and the contaminant to be monitored. Species used to investigate the input of contaminants from atmospheric deposition, for example, may differ from those used to assess transfer through food webs. Mosses and lichens have been particularly widely used in many countries to show distribution of metals and radionuclides on local and regional scales and of pesticide contamination. Visible injury to foliage of higher plant species may reflect atmospheric concentrations of gaseous pollutants and monitoring networks of transplanted sensitive species can provide information on contaminant levels on a regional scale. Changes in species composition, especially of lichens, have also been related to the degree of contamination.

  15. Effective radiological contamination control and monitoring techniques in high alpha environments.

    Science.gov (United States)

    Funke, Kevin C

    2003-02-01

    In the decommissioning of a highly contaminated alpha environment, such as the one at Hanford's 233-S Plutonium Concentration Facility, one of the key elements of a successful radiological control program is an integrated safety approach. This approach begins with the job-planning phase where the scope of the work is described. This is followed by a brainstorming session involving engineering and craft to identify how to perform the work in a logical sequence of events. Once the brainstorming session is over, a Job Hazard Analysis is performed to identify any potential problems. Mockups are utilized to enable the craft to get hands on experience and provide feedback and ideas to make the job run smoother. Ideas and experience gained during mockups are incorporated into the task instruction. To assure appropriate data are used in planning and executing the job, our principal evaluation tools included lapel and workplace air sampling, plus continuous air monitors and frequent surveys to effectively monitor job progress. In this highly contaminated alpha environment, with contamination levels ranging from 0.3 Bq cm-2 to approximately 100,000 Bq cm-2 (2,000 dpm per 100 cm2 to approximately 600 million dpm per 100 cm2), with average working levels of 1,600-3,200 Bq cm-2 (10-20 million dpm per 100 cm2) without concomitant ambient radiation levels, control of the spread of contamination is key to keeping airborne levels As Low As Reasonably Achievable.

  16. Unregulated Contaminant Monitoring Program Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA uses the Unregulated Contaminant Monitoring (UCM) program to collect data for contaminants suspected to be present in drinking water, but that do not have...

  17. Development of remote operated floor contamination monitor

    International Nuclear Information System (INIS)

    Sreekumar, K.; Gangamohan, M.; Kannan, R.K.; Rajan, S.

    2005-01-01

    Contamination check of floors and walkways in and around Reactor building areas forms an integral part of Radiation Protection Program in Power Stations. Though random swipe check method is adopted for the detection of loose contamination, this method has the disadvantage of leaving the fixed contamination and hotspots undetected. Hence, scanning the area with a sensitive detector, held close to the surface provides positive means for the detection of contamination. Checking large areas and walkways by holding the detector close to the surface involves physical work. Also, areas which are unapproachable due to congestion of equipment, may go uncovered by contamination monitoring in order to eliminate the physical strain involved in such contamination monitoring and to cover unapproachable areas, a small size prototype device that can be operated remotely was fabricated. This device detects contamination instantaneously and accurately. This paper describes design and fabrication of the device used for floor contamination monitoring. (author)

  18. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  19. Status of contamination monitoring in Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Begum, Aleya [Institute of Nuclear Science and Technology, Savar, Dacca (Bangladesh)

    1997-06-01

    The applications of radioisotopes and radiation sources to the research and development in medicine, food agriculture, industries and others are rapidly increasing in Bangladesh. The existing major nuclear facilites and allied laboratories of the country include 3 MW TRIGA Mark-2 research reactor for training, research and radioisotope production, 14 MeV neutron generator for nuclear data measurement and elemental analysis via neutron activation, 3 MeV Van de Graaff accelerator for the research and application of nuclear physics, and 50,000 Ci and 5,000 Ci Co-60 irradiators. About 10 Co-60 and Cs-137 teletherapy units are in operation in hospitals. The radioactive contamination of working areas, equipment, protective clothing and skin may result from normal operation and accidents, and contamination monitoring and decontamination are the essential part of radiation protection program. Surface contamination is monitored with Berthold survey meters. Hand and foot monitors have been used. Routine systematic search, continuous air monitoring, the examination of silt movement in Chittagong harbor using Sc-46 tracer and the measurement of tritium contamination for the neutron generator are reported. (K.I.)

  20. Monitoring of overalls and personnel skin contamination

    International Nuclear Information System (INIS)

    Turkin, N.F.

    1980-01-01

    Organization of monitoring of overalls and personnel skin contamination wastes is considered. The devices used for this purpose are enumerated. In sanitary sluices through which the personnel leaving the repair zone it is recommended to particularly thoroughly control hand skin contamination and most contaminated parts of overalls (sleeves, breeches lower parts, pockets, stomack region). In sanitary check points during personnel leaving the operator zone monitoring of overalls and skin contamination is performed. The overalls and other individual protective clothing are subjected to control in a special loundry before and after washing (decontamination) [ru

  1. Automated contamination monitoring for hot particles

    International Nuclear Information System (INIS)

    Johnstone, G.; Case, L.

    1987-01-01

    INS Corp., the largest nuclear laundry company in the United States, has recently developed two types of automated contamination monitoring systems: 1) the Automated Laundry Monitor (ALM), which provides quality assurance monitoring for protective clothing contamination and 2) a low-level automated monitoring system for Plastic Volume Reduction Service (PVRS). The presentation details the inaccuracies associated with hand-probe frisking which led to the development of the ALM. The ALM was designed for 100% quality assurance monitoring of garments to the most stringent customer requirements. A review of why the ALM is essential in verifying the absence of hot particles on garments is given. The final topic addresses the expansion of the ALM technology in support of the INS Plastic Volume Reduction Service by monitoring decontaminated plastics to free release levels. This presentation reviews the design and operation of both monitoring systems

  2. Chapter 7. Monitoring of chemical contamination of the environment and analytical-chemical monitoring

    International Nuclear Information System (INIS)

    Sojak, L.

    2006-01-01

    This chapter deals with the monitoring of chemical contamination of the environment and analytical-chemical monitoring. There are presented: the concept o monitoring of the environment of the Slovak Republic; unified monitoring system and complex information about state and development of the environment; analytical methods determination of chemical contaminants in the environment

  3. The design of hands and feet contamination monitor

    International Nuclear Information System (INIS)

    Song Jiangxue; Shen Yang; Deng Changming; Zhang Jia; Hou Lei; Meng Dan

    2011-01-01

    In order to protect the hands and feet of personnel engaged in nuclear, draw on advanced hands and feet contamination monitor, we design a new radiation protection instrumentation. It describes the composition of the hands and feet contamination monitor, and software program design. It describes the hardware monitor software, firmware and computer programming techniques. If device found your hand and foot surface is contamination, it will prompt you to decontamination, to protect your hands and feet of safety. (authors)

  4. Organization of internal contamination monitoring

    International Nuclear Information System (INIS)

    Badreddine, A.

    1986-07-01

    The nuclear energy takes a big part in the world's energy production. The nuclear techniques are used in most fields of life. Nevertheless the use of radioactive materials may cause prejudice to human beings by radiation contamination. The International Commission on Radiological Protection gives the general rules and regulations to avoid this danger. In the publication No. 30, the ICRP gives a metabolic model for the respiratory system and values of Annual Limit of Intake. The ALI for inhalation supposes a standard AMAD (Activity Median Aerodynamic Diameter) of 1 um. We have measured the AMAD in a laboratory under different conditions of functioning in order to show its variation. Then we have analysed the effect of this variation on the internal contamination monitoring. Thus we have calculated the Effective Committed Dose (ECD), the ALI, then the Derived Investigation Level (DIL) for different values of AMAD for Whole-Body Counting (WBC)

  5. Proximal spectral sensing to monitor phytoremediation of metal - contaminated soils

    NARCIS (Netherlands)

    Rathod, P.H.; Rossiter, D.; Noomen, M.; van der Meer, F.D.

    2013-01-01

    Assessment of soil contamination and its long-term monitoring are necessary to evaluate the effectiveness of phytoremediation systems. Spectral sensing-based monitoring methods promise obvious benefits compared to field-based methods: lower cost, faster data acquisition and better spatio-temporal

  6. A Coupled model for ERT monitoring of contaminated sites

    Science.gov (United States)

    Wang, Yuling; Zhang, Bo; Gong, Shulan; Xu, Ya

    2018-02-01

    The performance of electrical resistivity tomography (ERT) system is usually investigated using a fixed resistivity distribution model in numerical simulation study. In this paper, a method to construct a time-varying resistivity model by coupling water transport, solute transport and constant current field is proposed for ERT monitoring of contaminated sites. Using the proposed method, a monitoring model is constructed for a contaminated site with a pollution region on the surface and ERT monitoring results at different time is calculated by the finite element method. The results show that ERT monitoring profiles can effectively reflect the increase of the pollution area caused by the diffusion of pollutants, but the extent of the pollution is not exactly the same as the actual situation. The model can be extended to any other case and can be used to scheme design and results analysis for ERT monitoring.

  7. Radioactive contamination in monitors received for calibration

    International Nuclear Information System (INIS)

    Dias, Paulo S.; Santos, Gilvan C. dos; Brunelo, Maria Antonieta G.; Paula, Tiago C. de; Pires, Marina A.; Borges, Jose C.

    2013-01-01

    The Calibration Laboratory - LABCAL, from the Research Center for Metrology and Testing - METROBRAS, MRA Comercio de Instrumentos Eletronicos Ltda., began activities in October 2008 and, in August 2009, decided to establish a procedure for monitoring tests, external and internal, of all packages received from customers, containing instruments for calibration. The aim was to investigate possible contamination radioactive on these instruments. On July 2011, this procedure was extended to packagings of personal thermoluminescent dosemeters - TLD, received by the newly created Laboratory Laboratorio de Dosimetria Pessoal - LDP . In the monitoring procedure were used monitors with external probe, type pancake, MRA brand, models GP - 500 and MIR 7028. During the 37 months in which this investigation was conducted, were detected 42 cases of radioactive contamination, with the following characteristics: 1) just one case was personal dosimeter, TLD type; 2) just one case was not from a packing from nuclear medicine service - was from a mining company; 3) contamination occurred on packs and instruments, located and/or widespread; 4) contamination values ranged from slightly above the level of background radiation to about a thousand fold. Although METROBRAS has facilities for decontamination, in most cases, especially those of higher contamination, the procedure followed was to store the contaminated material in a room used for storage of radioactive sources. Periodically, each package and/or instrument was monitored, being released when the radiation level matched the background radiation. Every contamination detected, the client and/or owner of the instrument was informed. The Brazilian National Energy Commission - CNEN, was informed, during your public consultation for reviewing the standard for nuclear medicine services, held in mid-2012, having received from METROBRAS the statistical data available at the time. The high frequency of contamination detected and the high

  8. Monitoring of atmospheric contamination by plutonium in laboratories

    International Nuclear Information System (INIS)

    Pomarola, J.; Risselin, A.; Feliers, P.

    1965-02-01

    Immediate detection of atmospheric contamination by plutonium is necessary for warning of operators. A precise estimate of the level of this contamination is also necessary in order to give the Medical Section proper information. Experiments have been carried out at CEN-FAR using atmospheric contamination by plutonium monitors. This paper deals successively with: important problems of monitoring, the carrying out of the experiments and the results yielded. (authors) [fr

  9. Considerations of selection suggested for internal contamination monitoring in Cuba

    International Nuclear Information System (INIS)

    Cruz S, R.; Lopez B, G.; Placeres V, C.; Arado L, J.; Jova S, L.

    1996-01-01

    A method for calculating effective risk of radionuclide intake and hypothetical annual dose that will receive a person who works with unsealed sources is proposed. Calculated committed dose equivalent and metabolic characteristic of radionuclides permit to select the type of monitoring 'in vivo' and/or 'in vitro'. The method was applied to 396 workers from 28 institutions, where 20 radionuclides in 124 different products for 266 applications are used. From this study 62% of the workers had to be monitored for internal contamination, meanly by 'in vitro' monitoring. In practices of Nuclear Medicine and other medical uses 75% of the workers had to be monitored. These results permitted to corroborate the criteria for internal contamination monitoring program carried out by Center for Hygiene and Radiation Protection and permitted to identify needs for control of radionuclides intakes. (authors).5 refs., 3 figs

  10. An overview of existing raptor contaminant monitoring activities in Europe.

    Science.gov (United States)

    Gómez-Ramírez, P; Shore, R F; van den Brink, N W; van Hattum, B; Bustnes, J O; Duke, G; Fritsch, C; García-Fernández, A J; Helander, B O; Jaspers, V; Krone, O; Martínez-López, E; Mateo, R; Movalli, P; Sonne, C

    2014-06-01

    Biomonitoring using raptors as sentinels can provide early warning of the potential impacts of contaminants on humans and the environment and also a means of tracking the success of associated mitigation measures. Examples include detection of heavy metal-induced immune system impairment, PCB-induced altered reproductive impacts, and toxicity associated with lead in shot game. Authorisation of such releases and implementation of mitigation is now increasingly delivered through EU-wide directives but there is little established pan-European monitoring to quantify outcomes. We investigated the potential for EU-wide coordinated contaminant monitoring using raptors as sentinels. We did this using a questionnaire to ascertain the current scale of national activity across 44 European countries. According to this survey, there have been 52 different contaminant monitoring schemes with raptors over the last 50years. There were active schemes in 15 (predominantly western European) countries and 23 schemes have been running for >20years; most monitoring was conducted for >5years. Legacy persistent organic compounds (specifically organochlorine insecticides and PCBs), and metals/metalloids were monitored in most of the 15 countries. Fungicides, flame retardants and anticoagulant rodenticides were also relatively frequently monitored (each in at least 6 countries). Common buzzard (Buteo buteo), common kestrel (Falco tinnunculus), golden eagle (Aquila chrysaetos), white-tailed sea eagle (Haliaeetus albicilla), peregrine falcon (Falco peregrinus), tawny owl (Strix aluco) and barn owl (Tyto alba) were most commonly monitored (each in 6-10 countries). Feathers and eggs were most widely analysed although many schemes also analysed body tissues. Our study reveals an existing capability across multiple European countries for contaminant monitoring using raptors. However, coordination between existing schemes and expansion of monitoring into Eastern Europe is needed. This would enable

  11. Monitoring and evaluation techniques for airborne contamination

    Energy Technology Data Exchange (ETDEWEB)

    Yihua, Xia [China Inst. of Atomic Energy, Beijing (China)

    1997-06-01

    Monitoring and evaluation of airborne contamination are of great importance for the purpose of protection of health and safety of workers in nuclear installations. Because airborne contamination is one of the key sources to cause exposure to individuals by inhalation and digestion, and to cause diffusion of contaminants in the environment. The main objectives of monitoring and evaluation of airborne contamination are: to detect promptly a loss of control of airborne material, to help identify those individuals and predict exposure levels, to assess the intake and dose commitment to the individuals, and to provide sufficient documentation of airborne radioactivity. From the viewpoint of radiation protection, the radioactive contaminants in air can be classified into the following types: airborne aerosol, gas and noble gas, and volatile gas. In this paper, the following items are described: sampling methods and techniques, measurement and evaluation, and particle size analysis. (G.K.)

  12. Monitoring and evaluation techniques for airborne contamination

    International Nuclear Information System (INIS)

    Xia Yihua

    1997-01-01

    Monitoring and evaluation of airborne contamination are of great importance for the purpose of protection of health and safety of workers in nuclear installations. Because airborne contamination is one of the key sources to cause exposure to individuals by inhalation and digestion, and to cause diffusion of contaminants in the environment. The main objectives of monitoring and evaluation of airborne contamination are: to detect promptly a loss of control of airborne material, to help identify those individuals and predict exposure levels, to assess the intake and dose commitment to the individuals, and to provide sufficient documentation of airborne radioactivity. From the viewpoint of radiation protection, the radioactive contaminants in air can be classified into the following types: airborne aerosol, gas and noble gas, and volatile gas. In this paper, the following items are described: sampling methods and techniques, measurement and evaluation, and particle size analysis. (G.K.)

  13. Understanding Fluid and Contaminant Movement in the Unsaturated Zone Using the INEEL Vadose Zone Monitoring System

    International Nuclear Information System (INIS)

    Hubbell, J. M.; Mattson, E. D.; Sisson, J. B.; Magnuson, S. O.

    2002-01-01

    DOE has hundreds of contaminated facilities and waste sites requiring cleanup and/or long-term monitoring. These contaminated sites reside in unsaturated soils (i.e. the vadose zone) above the water table. Some of these sites will require active remediation activities or removal while other sites will be placed under institutional controls. In either case, evaluating the effectiveness of the remediation strategy or institutional controls will require monitoring. Classical monitoring strategies implemented at RCRA/CERCLA sites require ground water sampling for 30 years following closure. The overall effectiveness of ground water sampling is diminished due to the fact that by the time you detect chemical transport from a waste site, a major contamination plume likely exists in the vadose zone and the aquifer. This paper suggests a more effective monitoring strategy through monitoring near the contaminant sites within the vadose zone. Vadose zone monitoring allows for quicker detection of potential contaminant transport. The INEEL Vadose Zone Monitoring System (VZMS) is becoming an accepted, cost effective monitoring technology for assessing contaminant transport at DOE facilities. This paper describes the technologies employed in the VZMS and describes how it was used at several DOE facilities. The INEEL VZMS has provided the information in developing and validating both conceptual and risk assessment models of contaminant transport at the Idaho National Engineering and Environmental Laboratory (INEEL), Oak Ridge National Laboratory (ORNL), Savannah River Site (SRS) and the Hanford site. These DOE sites exhibit a broad range of meteorologic, hydrologic and geologic conditions representative of various common geologic environments. The VZMS is comprised of advanced tensiometers, water content sensors, temperature sensors and soil and gas samplers. These instruments are placed at multiple depths in boreholes and allows for the detection of water movement in the

  14. Belted kingfishers as ecological monitors of contamination: A review

    International Nuclear Information System (INIS)

    Landrum, C.L.

    1993-03-01

    Aquatic systems serve as transport pathways and reservoirs for most of the contaminants known to be present on the Oak Ridge Reservation (ORR). Organisms that live in aquatic systems accumulate some of these contaminants from their food and directly from the water or sediment. A wide array of terrestrial organisms feeds on aquatic organisms and may accumulate contaminants from aquatic prey. The belted kingfisher (Ceryle alcyon) is a piscivorous and territorial avian species that may be a suitable monitor of contaminant accumulation at specific sites on the ORR. A kingfisher collected on White Oak Lake in 1991 had a 137 Cs concentration of 568 pCi/g in muscle tissue, which exceeds levels found in any other waterfowl collected from the lake. An investigation into the efficacy of using the kingfisher as an ecological indicator of aquatic contaminants on the ORR was initiated in late August 1992. The primary objective of this study was to acquire information concerning the ecology of the kingfisher to determine how the species could be used within the framework of the Biological Monitoring and Abatement Program at Oak Ridge National Laboratory (ORNL). A second important objective of the study was to examine the possible somatic and reproductive effects of polychlorinated biphenyls (PCBs), Hg, and various radioactive contaminants on piscivorous birds by reviewing pollution ecology studies conducted on those species

  15. Belted kingfishers as ecological monitors of contamination: A review

    Energy Technology Data Exchange (ETDEWEB)

    Landrum, C.L. [North Texas Univ., Denton, TX (United States). Dept. of Biology; Ashwood, T.L.; Cox, D.K. [Oak Ridge National Lab., TN (United States)

    1993-03-01

    Aquatic systems serve as transport pathways and reservoirs for most of the contaminants known to be present on the Oak Ridge Reservation (ORR). Organisms that live in aquatic systems accumulate some of these contaminants from their food and directly from the water or sediment. A wide array of terrestrial organisms feeds on aquatic organisms and may accumulate contaminants from aquatic prey. The belted kingfisher (Ceryle alcyon) is a piscivorous and territorial avian species that may be a suitable monitor of contaminant accumulation at specific sites on the ORR. A kingfisher collected on White Oak Lake in 1991 had a {sup 137}Cs concentration of 568 pCi/g in muscle tissue, which exceeds levels found in any other waterfowl collected from the lake. An investigation into the efficacy of using the kingfisher as an ecological indicator of aquatic contaminants on the ORR was initiated in late August 1992. The primary objective of this study was to acquire information concerning the ecology of the kingfisher to determine how the species could be used within the framework of the Biological Monitoring and Abatement Program at Oak Ridge National Laboratory (ORNL). A second important objective of the study was to examine the possible somatic and reproductive effects of polychlorinated biphenyls (PCBs), Hg, and various radioactive contaminants on piscivorous birds by reviewing pollution ecology studies conducted on those species.

  16. A new risk and stochastic analysis of monitoring and remediation in subsurface contamination

    Science.gov (United States)

    Papapetridis, K.; Paleologos, E.

    2012-04-01

    Sanitary landfills constitute the most widely used management approach for the disposal of solid wastes because of their simplicity and cost effectiveness. However, historical records indicate that landfills exhibit a high failure rate of groundwater contamination. Successful detection of aquifer contamination via monitoring wells is a complicated problem with many factors, such as the heterogeneity of the geologic environment, the dispersion of contamination into the geologic medium, the quantity and nature of the contaminants, the number and location of the monitoring wells, and the frequency of sampling, all contributing to the uncertainty of early detection. Detection of contaminants, of course, is of value if remedial actions follow as soon as possible, so that the volume of contaminated groundwater to be treated is minimized. Practically, there is always a time lag between contaminant detection and remedial action response. Administrative decisions and arrangements with local contractors initiate remedial procedures introduces a time lag between detection and remediation time. During this time lag a plume continues to move into an aquifer contaminating larger groundwater volumes. In the present study these issues are addressed by investigating the case of instantaneous leakage from a landfill facility into a heterogeneous aquifer. The stochastic Monte Carlo framework was used to address, in two dimensions, the problem of evaluating the effectiveness of contaminant detection in heterogeneous aquifers by linear networks of monitoring wells. Numerical experiments based on the random-walk tracking-particle method were conducted to determine the detection probabilities and to calculate contaminated areas at different time steps. Several cases were studied assuming different levels of geologic heterogeneity, contamination dispersion, detectable contamination limits and monitoring wells' sampling frequencies. A new perspective is introduced for the correction of

  17. [Research on hyperspectral remote sensing in monitoring snow contamination concentration].

    Science.gov (United States)

    Tang, Xu-guang; Liu, Dian-wei; Zhang, Bai; Du, Jia; Lei, Xiao-chun; Zeng, Li-hong; Wang, Yuan-dong; Song, Kai-shan

    2011-05-01

    Contaminants in the snow can be used to reflect regional and global environmental pollution caused by human activities. However, so far, the research on space-time monitoring of snow contamination concentration for a wide range or areas difficult for human to reach is very scarce. In the present paper, based on the simulated atmospheric deposition experiments, the spectroscopy technique method was applied to analyze the effect of different contamination concentration on the snow reflectance spectra. Then an evaluation of snow contamination concentration (SCC) retrieval methods was conducted using characteristic index method (SDI), principal component analysis (PCA), BP neural network and RBF neural network method, and the estimate effects of four methods were compared. The results showed that the neural network model combined with hyperspectral remote sensing data could estimate the SCC well.

  18. Monitoring of plutonium contaminated solid waste streams

    International Nuclear Information System (INIS)

    Birkhoff, G.; Notea, A.

    1977-01-01

    The planning of a system for monitoring Pu contaminated solid waste streams, from the nuclear fuel cycle, is considered on the basis of given facility waste management program. The inter relations between the monitoring system and the waste management objectives are stressed. Selection criteria with pertinent data of available waste monitors are given. Example of monitoring systems planning are presented and discussed

  19. Is the soil quality monitoring an effective tool in consumers' protection of agricultural crops from cadmium soil contamination?-a case of the Silesia region (Poland).

    Science.gov (United States)

    Piekut, Agata; Baranowska, Renata; Marchwińska-Wyrwał, Ewa; Ćwieląg-Drabek, Małgorzata; Hajok, Ilona; Dziubanek, Grzegorz; Grochowska-Niedworok, Elżbieta

    2017-12-16

    The monitoring of soil quality should be a control tool used to reduce the adverse health effects arising from exposure to toxic chemicals in soil through cultivated crop absorption. The aim of the study was to evaluate the effectiveness of the monitoring and control system of soil quality in Poland, in terms of consumer safety, for agricultural plants cultivated in areas with known serious cadmium contamination, such as Silesia Province. To achieve the objective, the contents of cadmium in soils and vegetables in the Silesia administrative area were examined. The obtained results were compared with the results of soil contamination from the quality monitoring of arable soil in Poland. The studies show a significant exceedance of the permissible values of cadmium in soil samples and the vegetables cultivated on that soil. The threat to consumer health is a valid concern, although this threat was not indicated by the results of the national monitoring of soil quality. The results indicated an unequal distribution of risk to consumers resulting from contaminated soil. Moreover, the monitoring systems should be designed at the local or regional scale to guarantee the safety of consumers of edible plants cultivated in the areas contaminated with cadmium.

  20. Subsurface Contaminant Focus Area: Monitored Natural Attenuation (MNA)--Programmatic, Technical, and Regulatory Issues

    Energy Technology Data Exchange (ETDEWEB)

    Krupka, Kenneth M.; Martin, Wayne J.

    2001-07-23

    Natural attenuation processes are commonly used for remediation of contaminated sites. A variety of natural processes occur without human intervention at all sites to varying rates and degrees of effectiveness to attenuate (decrease) the mass, toxicity, mobility, volume, or concentration of organic and inorganic contaminants in soil, groundwater, and surface water systems. The objective of this review is to identify potential technical investments to be incorporated in the Subsurface Contaminant Focus Area Strategic Plan for monitored natural attenuation. When implemented, the technical investments will help evaluate and implement monitored natural attenuation as a remediation option at DOE sites. The outcome of this review is a set of conclusions and general recommendations regarding research needs, programmatic guidance, and stakeholder issues pertaining to monitored natural attenuation for the DOE complex.

  1. Study of monitoring protection of radionuclides contamination in organism by autoradiography

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Kang Baoan; He Guangren

    1987-01-01

    In view of the exceptionally important role of the medical radiation protection in human health, the authors try to study on the monitoring of internal contamination of radionuclides in organism by different autoradiographic methods, such as: monitoring of the body retention of isolated or combined radionuclides by freezing microautoradiography; monitoring of blood, bone marrow and excreta radioactive samples by smear autoradiography; differentiation of two radionuclides contamination by double radionuclide autoradiography; especially, monitoring of low level of radionuclides contamination by fluorescence sensitization autoradiography. The sensitivity of autoradiographic formation was increased by the scintillator by 10 times

  2. A portable contamination monitor with a numerical display

    International Nuclear Information System (INIS)

    Jones, A.R.

    1980-10-01

    A portable contamination monitor, its performance and application are described. The monitor is equipped with two 15.5 cm 2 'pancake' type Geiger-Mueller counters with thin windows ( 2 ). The summed counting rate is displayed in the range 0.2000 counts/s on a liquid crystal digital voltmeter. Every tenth pulse is signaled by flashing an LED and emitting a short (0.1 s) pulse of sound. The efficiencies for detecting a variety of α-, β- and γ- emitters have been measured and are reported. Data on the effects of varying battery voltage and temperature are also reported. (auth)

  3. Modeling, Monitoring and Fault Diagnosis of Spacecraft Air Contaminants

    Science.gov (United States)

    Ramirez, W. Fred; Skliar, Mikhail; Narayan, Anand; Morgenthaler, George W.; Smith, Gerald J.

    1998-01-01

    Control of air contaminants is a crucial factor in the safety considerations of crewed space flight. Indoor air quality needs to be closely monitored during long range missions such as a Mars mission, and also on large complex space structures such as the International Space Station. This work mainly pertains to the detection and simulation of air contaminants in the space station, though much of the work is easily extended to buildings, and issues of ventilation systems. Here we propose a method with which to track the presence of contaminants using an accurate physical model, and also develop a robust procedure that would raise alarms when certain tolerance levels are exceeded. A part of this research concerns the modeling of air flow inside a spacecraft, and the consequent dispersal pattern of contaminants. Our objective is to also monitor the contaminants on-line, so we develop a state estimation procedure that makes use of the measurements from a sensor system and determines an optimal estimate of the contamination in the system as a function of time and space. The real-time optimal estimates in turn are used to detect faults in the system and also offer diagnoses as to their sources. This work is concerned with the monitoring of air contaminants aboard future generation spacecraft and seeks to satisfy NASA's requirements as outlined in their Strategic Plan document (Technology Development Requirements, 1996).

  4. On indoor radon contamination monitoring with SSNTDs: Experimental results concerning plate-out and self-plate-out effects

    International Nuclear Information System (INIS)

    Bigazzi, G.; Hadler, J.C.; Paulo, S.R.

    1989-01-01

    Measurements of the alpha activities of 222 Rn and its daughters were performed, both inside a glass recipient and in closed rooms, employing SSNTDs (CR-39 and nuclear emulsion). The experimental results presented here show that plate-out and self-plate-out effects should be taken into account when SSNTDs are employed in indoor radon contamination monitoring. (orig.)

  5. Total effective dose equivalent associated with fixed uranium surface contamination

    International Nuclear Information System (INIS)

    Bogard, J.S.; Hamm, R.N.; Ashley, J.C.; Turner, J.E.; England, C.A.; Swenson, D.E.; Brown, K.S.

    1997-04-01

    This report provides the technical basis for establishing a uranium fixed-contamination action level, a fixed uranium surface contamination level exceeding the total radioactivity values of Appendix D of Title 10, Code of Federal Regulations, part 835 (10CFR835), but below which the monitoring, posting, and control requirements for Radiological Areas are not required for the area of the contamination. An area of fixed uranium contamination between 1,000 dpm/100 cm 2 and that level corresponding to an annual total effective dose equivalent (TEDE) of 100 mrem requires only routine monitoring, posting to alert personnel of the contamination, and administrative control. The more extensive requirements for monitoring, posting, and control designated by 10CFR835 for Radiological Areas do not have to be applied for these intermediate fixed-contamination levels

  6. Optimization of monitoring sewage with radionuclide contaminants

    International Nuclear Information System (INIS)

    Egorov, V.N.

    1991-01-01

    Recommendations on optimization of monitoring contaminated sewage aimed at enviromental protection agxinst radioactive contamination at minimum cost are presented. The way of selecting water sampling technique depends on water composition stability and flow rate. Depending on the type of radionuclide distribution in the sewage one can estimate minimum frequency of sampling or number of samples sufficient for assuring reliability of the conclusion on the excess or non-excess of permissible radioactive contamination levels, as well as analysis assigned accuracy. By irregular contaminated sewage-discharge and possibility of short-term releases of different form and duration, sampling should be accomplished through automatic devices of continuons or periodic operation

  7. Radioactive contamination in monitors received for calibration; Contaminacao em monitores de radiacao recebidos para calibracao

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Paulo S.; Santos, Gilvan C. dos; Brunelo, Maria Antonieta G.; Paula, Tiago C. de; Pires, Marina A.; Borges, Jose C. [MRA Comercio de Instrumentos Eletronicos Ltda., Jardinopolis, SP (Brazil). Centro de Ensaios e Pesquisas em Metrologia (METROBRAS)

    2013-10-01

    The Calibration Laboratory - LABCAL, from the Research Center for Metrology and Testing - METROBRAS, MRA Comercio de Instrumentos Eletronicos Ltda., began activities in October 2008 and, in August 2009, decided to establish a procedure for monitoring tests, external and internal, of all packages received from customers, containing instruments for calibration. The aim was to investigate possible contamination radioactive on these instruments. On July 2011, this procedure was extended to packagings of personal thermoluminescent dosemeters - TLD, received by the newly created Laboratory Laboratorio de Dosimetria Pessoal - LDP . In the monitoring procedure were used monitors with external probe, type pancake, MRA brand, models GP - 500 and MIR 7028. During the 37 months in which this investigation was conducted, were detected 42 cases of radioactive contamination, with the following characteristics: 1) just one case was personal dosimeter, TLD type; 2) just one case was not from a packing from nuclear medicine service - was from a mining company; 3) contamination occurred on packs and instruments, located and/or widespread; 4) contamination values ranged from slightly above the level of background radiation to about a thousand fold. Although METROBRAS has facilities for decontamination, in most cases, especially those of higher contamination, the procedure followed was to store the contaminated material in a room used for storage of radioactive sources. Periodically, each package and/or instrument was monitored, being released when the radiation level matched the background radiation. Every contamination detected, the client and/or owner of the instrument was informed. The Brazilian National Energy Commission - CNEN, was informed, during your public consultation for reviewing the standard for nuclear medicine services, held in mid-2012, having received from METROBRAS the statistical data available at the time. The high frequency of contamination detected and the high

  8. Testing of portal monitors for personnel contamination control

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Stalker, A.C.; Baker, K.R.; Littleton, M.L.; Rich, B.L.

    1983-04-01

    This is a report of an INPO-funded evaluation of state-of-the-art portal monitors used to detect personnel contamination. The project developed techniques and procedures to evaluate the performance and sensitivity of the portal monitors which provided data for intercomparison. An additional accomplishment was development of a methodology to assist manufacturers and users to optimize the monitor settings, and to provide technical basis for the eventual use of fixed monitors to replace frisking for contamination control. The monitors tested utilize thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: (1) background count rate and the statistical variability, (2) detector efficiency at different distances, (3) moving source sensitivity for various size sources and speeds, and (4) false alarm rates at different background levels. A model has been developed for the moving source measurements to compare the experimental data, and to test whether it is possible to adequately model the behavior of a portal monitor response to a moving source. The model results with the actual test results are compared

  9. Evaluation of targeted and untargeted effects-based monitoring tools to assess impacts of contaminants of emerging concern on fish in the South Platte River, CO

    Science.gov (United States)

    Rivers in the arid Western United States face increasing influences from anthropogenic contaminants due to population growth, urbanization, and drought. To better understand and more effectively track the impacts of these contaminants, biologically-based monitoring tools are incr...

  10. The status on contamination monitoring in Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Sinakhom, Fookiat [Office of Atomic Energy for Peace, Bangkok (Thailand)

    1997-06-01

    Thailand has embarked upon the development of nuclear energy for peaceful utilizations since 1961 when the Atomic Energy for Peace Act was enacted. The Atomic Energy Commission (Thai AEC) was established under section 5 of this Act having power and duty of carrying out matters concerning atomic energy for peace. The applications of nuclear energy in Thailand, at present are exclusively in medicine, education, research and industry. In this paper, the following items are described on contamination monitoring: controllable monitoring, uncontrollable monitoring, standardization of monitoring instruments, and decontamination and waste management. (G.K.)

  11. Evaluation of targeted and untargeted effects-based monitoring tools to assess impacts of contaminants of emerging concern on fish in the South Platte River, CO.

    Science.gov (United States)

    Ekman, Drew R; Keteles, Kristen; Beihoffer, Jon; Cavallin, Jenna E; Dahlin, Kenneth; Davis, John M; Jastrow, Aaron; Lazorchak, James M; Mills, Marc A; Murphy, Mark; Nguyen, David; Vajda, Alan M; Villeneuve, Daniel L; Winkelman, Dana L; Collette, Timothy W

    2018-08-01

    Rivers in the arid Western United States face increasing influences from anthropogenic contaminants due to population growth, urbanization, and drought. To better understand and more effectively track the impacts of these contaminants, biologically-based monitoring tools are increasingly being used to complement routine chemical monitoring. This study was initiated to assess the ability of both targeted and untargeted biologically-based monitoring tools to discriminate impacts of two adjacent wastewater treatment plants (WWTPs) on Colorado's South Platte River. A cell-based estrogen assay (in vitro, targeted) determined that water samples collected downstream of the larger of the two WWTPs displayed considerable estrogenic activity in its two separate effluent streams. Hepatic vitellogenin mRNA expression (in vivo, targeted) and NMR-based metabolomic analyses (in vivo, untargeted) from caged male fathead minnows also suggested estrogenic activity downstream of the larger WWTP, but detected significant differences in responses from its two effluent streams. The metabolomic results suggested that these differences were associated with oxidative stress levels. Finally, partial least squares regression was used to explore linkages between the metabolomics responses and the chemical contaminants that were detected at the sites. This analysis, along with univariate statistical approaches, identified significant covariance between the biological endpoints and estrone concentrations, suggesting the importance of this contaminant and recommending increased focus on its presence in the environment. These results underscore the benefits of a combined targeted and untargeted biologically-based monitoring strategy when used alongside contaminant monitoring to more effectively assess ecological impacts of exposures to complex mixtures in surface waters. Published by Elsevier Ltd.

  12. Long-range alpha detection applied to soil contamination and waste monitoring

    International Nuclear Information System (INIS)

    MacArthur, D.W.; Allander, K.S.; Bounds, J.A.; Close, D.A.; McAtee, J.L.

    1992-01-01

    Alpha contamination monitoring has been traditionally limited by the short range of alpha particles in air and through detector windows. The long-range alpha detector (LRAD) described in this paper circumvents that limitation by detecting alpha-produced ions, rather than alpha particles directly. Since the LRAD is sensitive to all ions, it can monitor all contamination present on a large surface at one time. Because air is the ''detector gas,'' the LRAD can detect contamination on any surface to which air can penetrate. We present data showing the sensitivity of LRAD detectors, as well as documenting their ability to detect alpha sources in previously unmonitorable locations, and verifying the ion lifetime. Specific designs and results for soil contamination and waste monitors are also included

  13. Absorption-Edge-Modulated Transmission Spectra for Water Contaminant Monitoring

    Science.gov (United States)

    2016-03-31

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/6390--16-9675 Absorption- Edge -Modulated Transmission Spectra for Water Contaminant...ABSTRACT c. THIS PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT Absorption- Edge -Modulated Transmission Spectra for Water Contaminant Monitoring...contaminants, within a volume of sampled solution, requires sufficient sensitivity. The present study examines the sensitivity of absorption- edge

  14. Country report on contamination monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Oyuntulkhuur, Navaangalsan [National Centre for Hygiene, Epidemiology and Microbiology (Mongolia). Central Radiological Laboratory

    1997-06-01

    Mongolia is a non-nuclear country and has currently neither nuclear power plants nor research reactors. This country joined the Regional Co-operation Agreement (RCA) for the Asia Pacific region for research, development and training related to nuclear science and technology in 1993. Various measures has been taken for strengthening of radiation protection, cooperated with several international organizations mainly with IAEA. In Mongolia radioactive substances and sources are used for the following purposes: for research work; medical radiotherapy and diagnostic radiology in hospitals; industrial enterprises for technological processes; and for non-destructive testing in industry. Radiation safety inspection is conducted by the CRL. The inspections consist of verification of compliance with radiation safety requirements and with any additional requirements specified in the authorization of accounting records and a physical check on the presence of radiation sources; check on the work carried out by the radiation safety services to monitor radioactive contamination of the environment; and measurements and sampling. CRL should take much attention for improvement and development of the activities in the field of surface contamination monitoring concerning a wide use of radionuclides in different field of economy. (G.K.)

  15. Monitoring of tritium-contaminated surfaces, including skin

    International Nuclear Information System (INIS)

    Surette, R.A.; Wood, M.J.

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation's PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55's susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs

  16. Small mammals as monitors of environmental contaminants

    International Nuclear Information System (INIS)

    Talmage, S.S.; Walton, B.T.

    1991-01-01

    The merit of using small mammals as monitors of environmental contaminants was assessed using data from the published literature. Information was located on 35 species of small mammals from 7 families used to monitor heavy metals, radionuclides, and organic chemicals at mine sites, industrial areas, hazardous and radioactive waste disposal sites, and agricultural and forested land. To document foodchain transfer of chemicals, concentrations in soil, vegetation, and invertebrates, where available, were included. The most commonly trapped North American species were Peromyscus leucopus, Blarina brevicauda, and Microtus pennsylvanicus. In these species, exposure to chemicals was determined from tissue residue analyses, biochemical assays, and cytogenetic assays. Where enough information was available, suitable target tissues, or biological assays for specific chemicals were noted. In general, there was a relationship between concentrations of contaminants in the soil or food, and concentrations in target tissues of several species. This relationship was most obvious for the nonessential heavy metals, cadmium, lead, and mercury and for fluoride. Kidney was the single best tissue for residue analyses of inorganic contaminants. However, bone should be the tissue of choice for both lead and fluorine. Exposure to lead was also successfully documented using biochemical and histopathological endpoints. Bone was the tissue of choice for exposure to 90Sr, whereas muscle was an appropriate tissue for 137Cs. For organic contaminants, exposure endpoints depended on the chemical(s) of concern. Liver and whole-body residue analyses, as well as enzyme changes, organ histology, genotoxicity, and, in one case, population dynamics, were successfully used to document exposure to these contaminants

  17. Design and Development of Hand and Foot Contamination Monitor

    Directory of Open Access Journals (Sweden)

    F. Akter

    2014-08-01

    Full Text Available A hand and foot contamination monitor is a health physics instrument to provide detection and measurement of beta-gamma contamination on the palm of each hand and on the bottom surface of both feet/shoes. There are four channels of detection for two hands and two feet. Four G-M detectors have been used in a single unit to cover the whole area of hand and feet. A regulated high voltage DC power supply (900 V has been designed using the PIC12F675 microcontroller to operate the pancake Geiger-Müller detectors. The reading is displayed on a linearly scaled 0-100 Bq/cm2 analog panel meter. The monitor detects beta–gamma radiation emitted by radioactive materials, and if the detected value exceeds a preset level, the monitor sounds an alarm and displays a reading in the respective panel meter. Indicator lamps are used to show the status of contamination. The performance of the system has been tested by using pulse generator and by flat surface radioactive calibration sources. Electronic linearity, detection efficiency, response to the contamination, calibration factor and percentage of error has been measured. Test results were satisfactory and the present system can be used instead of similar imported instruments.

  18. Monitoring of tritium-contaminated surfaces, including skin

    Energy Technology Data Exchange (ETDEWEB)

    Surette, R A; Wood, M J

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation`s PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55`s susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs.

  19. Evaluation of surface contamination due to alpha using large area contamination monitors

    International Nuclear Information System (INIS)

    Raghavayya, M.

    1998-01-01

    Radioactive contamination at work places is evaluated routinely using either the swipe sampling technique or a contamination monitor. Commercially available alpha probes used for the purpose are usually circular and have a face diameter of 50 or 100 mm. Square faced probes are also available. A thin aluminized mylar membrane of thickness 0.45 to 0.9 mg.cm -2 is used to screen the phosphor in the alpha probe to protect it from external light. The membrane cuts off more alphas from low energy emitters than from higher energy alpha emitters. Moreover the response of the detector for alphas originating at all points under the detector face is not uniform, especially when the large area alpha monitors are used. These factors can introduce errors as high as 40% into the measurements. This paper aims to quantify these errors and describe a procedure to overcome the limitations. (author)

  20. Contaminant monitoring of hydraulic systems. The need for reliable data

    Energy Technology Data Exchange (ETDEWEB)

    Day, M.J. Rinkinen, J. [Pall Europe Ltd., Portsmouth (United Kingdom); Tampere University of Technology, Tampere (Finland)

    1998-12-31

    The need for both reliable operation of hydraulic and lubrication systems and long component lives has focused users to the benefits of controlling the contamination in the hydraulic fluid. Maximum operating (target) levels are being implemented as part of a condition based maintenance regime. If these are exceeded, maintenance effort is directed to correcting the rise in consummation level, and so make optimum use of resources as maintenance effort is only affected when it is necessary to do so. Fundamental to ibis aspect of condition based monitoring is the provision of accurate and reliable data in the shortest possible time. This way, corrective actions can be implemented immediately so minimising the damage to components. On-line monitoring devices are a way of achieving this and are seeing increased use, but some are affected by the condition of the fluid. Hence, there is a potential for giving incorrect data which will waste time and effort by initiating unnecessary corrective actions. A more disturbing aspect is the effect on the user of continual errors. The most likely effect would be a loss of confidence in the technique or even complete rejection of it and hence the potential benefits will be lost. This presentation explains how contaminant monitoring techniques are applied to ensure that the potential benefits of operating with clean fluids is realised. It examines the sources of error and shows how the user can interrogate the data and satisfy himself of its authenticity. (orig.) 14 refs.

  1. Contaminant monitoring of hydraulic systems. The need for reliable data

    Energy Technology Data Exchange (ETDEWEB)

    Day, M.J. [Pall Europe Ltd., Portsmouth (United Kingdom)] Rinkinen, J. [Tampere University of Technology, Tampere (Finland)

    1997-12-31

    The need for both reliable operation of hydraulic and lubrication systems and long component lives has focused users to the benefits of controlling the contamination in the hydraulic fluid. Maximum operating (target) levels are being implemented as part of a condition based maintenance regime. If these are exceeded, maintenance effort is directed to correcting the rise in consummation level, and so make optimum use of resources as maintenance effort is only affected when it is necessary to do so. Fundamental to ibis aspect of condition based monitoring is the provision of accurate and reliable data in the shortest possible time. This way, corrective actions can be implemented immediately so minimising the damage to components. On-line monitoring devices are a way of achieving this and are seeing increased use, but some are affected by the condition of the fluid. Hence, there is a potential for giving incorrect data which will waste time and effort by initiating unnecessary corrective actions. A more disturbing aspect is the effect on the user of continual errors. The most likely effect would be a loss of confidence in the technique or even complete rejection of it and hence the potential benefits will be lost. This presentation explains how contaminant monitoring techniques are applied to ensure that the potential benefits of operating with clean fluids is realised. It examines the sources of error and shows how the user can interrogate the data and satisfy himself of its authenticity. (orig.) 14 refs.

  2. GSFC contamination monitors for Space Station

    Science.gov (United States)

    Carosso, P. A.; Tveekrem, J. L.; Coopersmith, J. D.

    1988-01-01

    This paper describes the Work Package 3 activities in the area of neutral contamination monitoring for the Space Station. Goddard Space Flight Center's responsibilities include the development of the Attached Payload Accommodations Equipment (APAE), the Polar Orbiting Platform (POP), and the Flight Telerobotic Servicer (FTS). GSFC will also develop the Customer Servicing Facility (CSF) in Phase 2 of the Space Station.

  3. Monitoring of organic contaminants in sediments using low field proton nuclear magnetic resonance

    Science.gov (United States)

    Zhang, Chi; Rupert, Yuri

    2016-04-01

    The effective monitoring of soils and groundwater contaminated with organic compounds is an important goal of many environmental restoration efforts. Recent geophysical methods such as electrical resistivity, complex conductivity, and ground penetrating radar have been successfully applied to characterize organic contaminants in the subsurface and to monitor remediation process both in laboratory and in field. Low field proton nuclear magnetic resonance (NMR) is a geophysical tool sensitive to the molecular-scale physical and chemical environment of hydrogen-bearing fluids in geological materials and shows promise as a novel method for monitoring contaminant remediation. This laboratory research focuses on measurements on synthetic samples to determine the sensitivity of NMR to the presence of organic contaminants and improve understanding of relationships between NMR observables, hydrological properties of the sediments, and amount and state of contaminants in porous media. Toluene, a light non-aqueous phase liquid (LNAPL) has been selected as a representative organic contaminant. Three types of porous media (pure silica sands, montmorillonite clay, and various sand-clay mixtures with different sand/clay ratios) were prepared as synthetic sediments. NMR relaxation time (T2) and diffusion-relaxation (D - T2) correlation measurements were performed in each sediment saturated with water and toluene mixed fluid at assorted concentrations (0% toluene and 100% water, 1% toluene and 99% water, 5% toluene and 95% water, 25% toluene and 75% water, and 100% toluene and 0% water) to 1) understand the effect of different porous media on the NMR responses in each fluid mixture, 2) investigate the role of clay content on T2 relaxation of each fluid, 3) quantify the amount hydrocarbons in the presence of water in each sediment, and 4) resolve hydrocarbons from water in D - T2 map. Relationships between the compositions of porous media, hydrocarbon concentration, and hydraulic

  4. Using tree swallows to monitor impacts of aquatic contamination in Great Lakes areas of concern

    International Nuclear Information System (INIS)

    Patnode, K.A.; Bodenstein, B.; Hetzel, R.; Pearson, S.

    1995-01-01

    Tree swallows were used to evaluate movement and potential impacts of contaminants from sediments in Newton Creek (diesel range organics: DROs) and Sheboygan River (PCBs), tributaries to Lake Superior and Lake Michigan, respectively. Contaminated sites occurred along the course of each river, while reference sites were located upstream or on a nearby river. Productivity was monitored and eggs, day 1 nestlings, and day 12 nestlings were collected from each nest. Whole body or egg homogenates were analyzed for PCBs or DROs. EROD activity in livers from day 12 nestlings is being determined for both PCB and DRO exposures. In the Newton Creek study, hatching success was similar for DRO and reference sites. DROs were detected in gastrointestinal tracts of 1 nestling from the reference and 1 from the contaminated site. DROs were not detected in any egg samples. In the Sheboygan River study, hatching success rates differed between 1 reference and 1 contaminated river segment. PCB daily accumulation rates from day 1 to day 12 nestlings were computed for Sheboygan River. All nestlings at reference nests had negative rates due to growth dilution effects. Preliminary analyses indicate the average rate for nestlings from contaminated segments of the river was 220.3 ng/g/day. These 1995 findings will be combined with 1996 data to evaluate the effectiveness of tree swallows for monitoring ecosystem impacts of aquatic contaminants in Wisconsin

  5. Present status of contamination monitoring at the Dalat Nuclear Research Institute (DNRI)

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Hoang Van [Dalat Nuclear Research Inst. (Viet Nam)

    1997-06-01

    The Dalat nuclear research reactor was renovated and upgraded from the previous TRIGA reactor. In Vietnam, it is a unique nuclear device having suitable neutron flux for the radioisotope production and neutron activation analysis. Soon after the reactor reached its initial criticality in November 1983, a programme has been formed to develop the application of nuclear techniques in various fields. In addition, the use of radioisotopes for diagnostic, therapeutic and other research purposes has been in progress. In order to support these activities, the radiation protection, especially the radiation contamination monitoring has been properly paid attention to. In DNRI, the Radiation Protection Department is responsible for controlling and supervising radiation and working safety for all activities. In this paper, the following items are described on radiation contamination monitoring: controlled area, surface contamination monitoring, and airborne concentration monitoring. (G.K.)

  6. Integrating Modeling and Monitoring to Provide Long-Term Control of Contaminants

    International Nuclear Information System (INIS)

    Fogwell, Th.

    2009-01-01

    An introduction is presented of the types of problems that exist for long-term control of radionuclides at DOE sites. A breakdown of the distributions at specific sites is given, together with the associated difficulties. A paradigm for remediation showing the integration of monitoring with modeling is presented. It is based on a feedback system that allows for the monitoring to act as principal sensors in a control system. Currently the establishment of a very prescriptive monitoring program fails to have a mechanism for improving models and improving control of the contaminants. The resulting system can be optimized to improve performance. Optimizing monitoring automatically entails linking the monitoring with modeling. If monitoring designs were required to be more efficient, thus requiring optimization, then the monitoring automatically becomes linked to modeling. Records of decision could be written to accommodate revisions in monitoring as better modeling evolves. The technical pieces of the required paradigm are already available; they just need to be implemented and applied to solve the long-term control of the contaminants. An integration of the various parts of the system is presented. Each part is described, and examples are given. References are given to other projects which bring together similar elements in systems for the control of contaminants. Trends are given for the development of the technical features of a robust system. Examples of monitoring methods for specific sites are given. The examples are used to illustrate how such a system would work. Examples of technology needs are presented. Finally, other examples of integrated modeling-monitoring approaches are presented. (authors)

  7. Unregulated Contaminant Monitoring Rule 2 (UCMR 2), (2008-2010) Occurrence Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Unregulated Contaminant Monitoring Rule supporting the second cycle (UCMR 2) of monitoring, conducted under EPA oversight, was published in the Federal Register...

  8. In Situ Monitoring of Groundwater Contamination Using the Kalman Filter For Sustainable Remediation

    Science.gov (United States)

    Schmidt, F.; Wainwright, H. M.; Faybishenko, B.; Denham, M. E.; Eddy-Dilek, C. A.

    2017-12-01

    Sustainable remediation - based on less intensive passive remediation and natural attenuation - has become a desirable remediation alternative at contaminated sites. Although it has a number of benefits, such as reduced waste and water/energy usage, it carries a significant burden of proof to verify plume stability and to ensure insignificant increase of risk to public health. Modeling of contaminant transport is still challenging despite recent advances in numerical methods. Long-term monitoring has, therefore, become a critical component in sustainable remediation. However, the current approach, which relies on sparse groundwater sampling, is problematic, since it could miss sudden significant changes in plume behavior. A new method is needed to combine existing knowledge about contaminant behavior and latest advances in in situ groundwater sensors. This study presents an example of the effective use of the Kalman filter approach to estimate contaminant concentrations, based on in situ measured water quality parameters (e.g. electrical conductivity and pH) along with the results of sparse groundwater sampling. The Kalman filter can effectively couple physical models and data correlations between the contaminant concentrations and in situ measured variables. We aim (1) to develop a framework capable of integrating different data types to provide accurate contaminant concentration estimates, (2) to demonstrate that these results remain reliable, even when the groundwater sampling frequency is reduced, and (3) to evaluate the future efficacy of this strategy using reactive transport simulations. This framework can also serve as an early warning system for detecting unexpected plume migration. We demonstrate our approach using historical and current groundwater data from the Savannah River Site (SRS) F-Area Seepage Basins to estimate uranium and tritium concentrations. The results show that the developed method can provide reliable estimates of contaminant

  9. History, contamination and monitoring of water bodies at the P/A Mayak

    International Nuclear Information System (INIS)

    Drozhko, E.G.; Sharalapov, V.I.; Posokhov, A.K.; Kuzina, N.V.; Postovalova, G.A.

    1993-01-01

    The facts concerning the history and contamination data of surface water at Mayak Production Association are given in the article. Data about the monitoring of contaminated water are presented. The monitoring program solved three main problems: assessment of the water quality of basins, examination of water quality in accordance with actual specifications, and reception of new data about the migration of the most important radionuclides

  10. Optimisation of internal contamination monitoring programme by integration of uncertainties

    International Nuclear Information System (INIS)

    Davesne, E.; Casanova, P.; Chojnacki, E.; Paquet, F.; Blanchardon, E.

    2011-01-01

    Potential internal contamination of workers is monitored by periodic bioassay measurements interpreted in terms of intake and committed effective dose by the use of biokinetic and dosimetric models. After a prospective evaluation of exposure at a workplace, a suitable monitoring programme can be defined by choosing adequate measurement techniques and frequency. In this study, the sensitivity of a programme is evaluated by the minimum intake and dose, which may be detected with a given level of confidence by taking into account uncertainties on exposure conditions and measurements. This is made for programme optimisation, which is performed by comparing the sensitivities of different alternative programmes. These methods were applied at the AREVA NC reprocessing plant and support the current monitoring programme as the best compromise between the cost of the measurements and the sensitivity of the programme. (authors)

  11. Monitor for alpha beta contamination of hands; Moniteur de contamination alpha beta des mains

    Energy Technology Data Exchange (ETDEWEB)

    Guitton, J

    1958-07-01

    The following specifications of hands alpha beta contamination monitor are presented: the position of the hands, the detection and separation of alpha and beta, the information processing, the programming, the results presentation and general characteristics. (A.L.B.)

  12. Wireless Sensor Network Based Subsurface Contaminant Plume Monitoring

    Science.gov (United States)

    2012-04-16

    Sensor Network (WSN) to monitor contaminant plume movement in naturally heterogeneous subsurface formations to advance the sensor networking based...time to assess the source and predict future plume behavior. This proof-of-concept research aimed at demonstrating the use of an intelligent Wireless

  13. Caresoil: A multidisciplinar Project to characterize, remediate, monitor and evaluate the risk of contaminated soils in Madrid (Spain)

    Science.gov (United States)

    Muñoz-Martín, Alfonso; Antón, Loreto; Granja, Jose Luis; Villarroya, Fermín; Montero, Esperanza; Rodríguez, Vanesa

    2016-04-01

    Soil contamination can come from diffuse sources (air deposition, agriculture, etc.) or local sources, these last being related to anthropogenic activities that are potentially soil contaminating activities. According to data from the EU, in Spain, and particularly for the Autonomous Community of Madrid, it can be considered that heavy metals, toxic organic compounds (including Non Aqueous Phases Liquids, NAPLs) and combinations of both are the main problem of point sources of soil contamination in our community. The five aspects that will be applied in Caresoil Program (S2013/MAE-2739) in the analysis and remediation of a local soil contamination are: 1) the location of the source of contamination and characterization of soil and aquifer concerned, 2) evaluation of the dispersion of the plume, 3) application of effective remediation techniques, 4) monitoring the evolution of the contaminated soil and 5) risk analysis throughout this process. These aspects involve advanced technologies (hydrogeology, geophysics, geochemistry,...) that require new developing of knowledge, being necessary the contribution of several researching groups specialized in the fields previously cited, as they are those integrating CARESOIL Program. Actually two cases concerning hydrocarbon spills, as representative examples of soil local contamination in Madrid area, are being studied. The first is being remediated and we are monitoring this process to evaluate its effectiveness. In the second location we are defining the extent of contamination in soil and aquifer to define the most effective remediation technique.

  14. Evaluation of indigenously developed plastic scintillator sheet detector for surface radioactive contamination monitoring application

    International Nuclear Information System (INIS)

    Sahani, R.M.; Chaudhary, H.S.; Mahala, V.K.; Senwar, K.R.; Meena, J.P.

    2018-01-01

    Radioactive contamination may be caused by release of radioactivity in the environment due to accident at nuclear plant/reactor or spillage of loose radioactive materials in a laboratory. The protection of workers from potentially hazardous radiations emitted by the contaminants is a matter of prime concern. The detection of such radiations requires a monitoring system capable of measuring the level of radioactivity at the contaminated site. Plastic scintillators are widely used for large area radiation monitoring due to the ease of preparation in different shape and sizes. These detectors are sensitive to beta and gamma radiation therefore can be used for monitoring of beta and gamma contamination. In this paper, performance results of indigenously developed plastic scintillator sheet of area 800 cm 2 are reported

  15. Second IRMF comparison of surface contamination monitor calibrations 2001-2002

    CERN Document Server

    Scott, C J

    2002-01-01

    The Ionising Radiations Metrology Forum (IRMF) organised a second comparison of surface contamination monitor calibrations in which twenty establishments in the UK participated. The exercise involved the circulation of three surface contamination monitors for calibration using large area reference sources available in the participants' laboratories. The instruments used were a Mini Instruments EP15, a Berthold LB122 and an Electra ratemeter with DP6AD probe. The instrument responses were calculated by the individual participants and submitted to the for analysis along with details of the reference sources used. Details of the estimated uncertainties were also reported. The results are compared and demonstrate generally satisfactory agreement between the participating establishments.

  16. Osprey: worldwide sentinel species for assessing and monitoring environmental contamination in rivers, lakes, reservoirs, and estuaries.

    Science.gov (United States)

    Grove, Robert A; Henny, Charles J; Kaiser, James L

    2009-01-01

    In the United States, many fish and wildlife species have been used nationwide to monitor environmental contaminant exposure and effects, including carcasses of the bald eagle (Haliaeetus leucocephalus), the only top avian predator regularly used in the past. Unfortunately, bald eagles are sensitive to investigator intrusion at the nest. Thus, the osprey (Pandion haliaetus) is evaluated as a potential sentinel species for aquatic ecosystems. Several characteristics support the choice of the osprey as a sentinel species, including: (1) fish-eating diet atop the aquatic food web, (2) long-lived with strong nest fidelity, (3) adapts to human landscapes (potentially the most contaminated), (4) tolerates short-term nest disturbance, (5) nests spatially distributed at regular intervals, (6) highly visible nests easily located for study, (7) ability to accumulate most, if not all, lipophilic contaminants, (8) known sensitivity to many contaminants, and (9) nearly a worldwide distribution. These osprey traits have been instrumental in successfully using the species to understand population distribution, abundance, and changes over time; the effects of various contaminants on reproductive success; how contaminants in prey (fish on biomass basis) contribute to egg concentrations (i.e., biomagnification factors); and spatial residue patterns. Data summarized include nesting population surveys, detailed nesting studies, and chemical analyses of osprey egg, organ, blood, and feather samples for contaminants that bioaccumulate and/or biomagnify in aquatic food webs; and biochemical evaluations of blood and various organs. Studies in the United States, Canada, Mexico, Europe, and elsewhere have shown the osprey to be a useful sentinel species for monitoring selected environmental contaminants, including some emerging contaminants in lakes, reservoirs, rivers, and estuaries.

  17. Improvement of a device for monitoring the contamination of surfaces

    International Nuclear Information System (INIS)

    Barbier, Albert.

    1981-01-01

    The purpose of this invention is to make it possible to monitor the contamination of surfaces by a light weight portable device and enabling the alpha, beta and gamma radiation contamination to be detected. The detection probe which is connected by a single lead to the box is adapted, in each particular case, to the radiation mode emitted by the contaminated surfaces and the box is provided with a special leak-proof socket for connecting the probe and includes means for assessing the counting rate of the radiation given off, depending on the mode of the radiations emitted by the contaminated surfaces and the intensity of the count rate [fr

  18. ESI nuclear model 271 C contamination monitor

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    This instrument is a general purpose contamination monitor, comprising a GM tube connected by a coiled extensible cable to a ratemeter. The scale is marked quasi-logarithmically from 0 to 600 in 'counts per second'. The report falls under the headings: general description, facilities and controls, radiation performance, electrical characteristics, environmental characteristics, mechanical characteristics, summary of performance, conclusions. (U.K.)

  19. Contamination Control and Monitoring of Tap Water as Fluid in Industrial Tap Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Conrad, Finn; Adelstorp, Anders

    1998-01-01

    Presentation of results and methods addressed to contamination control and monitoring of tap water as fluid in tap water hydraulic systems.......Presentation of results and methods addressed to contamination control and monitoring of tap water as fluid in tap water hydraulic systems....

  20. Evaluation of natural attenuation processes in the groundwater of a tar oil contaminated site: development of a monitoring network

    International Nuclear Information System (INIS)

    Borke, P.; Husers, N.; Werner, P.; Leibenath, C.

    2005-01-01

    related design with at least two control planes is recommended. Based on the experiences at the wood preservation site a three phase monitoring approach is proposed: (1) site characterization monitoring network to describe the disposition of contaminants and the dimension of the plume, (2) stage of testing and enhancing the network to determine whether the NA is occurring, to observe the plume stability and to be able to determine the mass flux and setting the performance goals and (3) long term monitoring of performance goals to make sure that the contaminant plume does not change and performance is achieved. Properly designed monitoring network in conjunction with NA can be an effective alternative or supplementary tool for the remediation of a site contaminated with tar oil. (authors)

  1. Determination of contamination operational value by routine monitoring in research laboratories

    International Nuclear Information System (INIS)

    Salomao, Edeilson; Medeiros, Regina Bitelli; Mattos, Maria Fernanda S.S.; Daros, Kellen Adriana Curci

    2008-01-01

    The radioisotopes have a large spectrum of applicability in many areas of science, as in medicine, agriculture and industry in general. In the biological area, the radioisotopes have brought many benefits to study physiological processes in living organisms and in vitro. The most radioisotopes used in biological research are emitters of radiation of low energy, mainly β, and are used as unsealed sources. The manipulation of these radioisotopes generates radioactive wastes and eventually can cause contamination in the areas of handling or even occasionally in areas to which access is not controlled. According to CNEN-NE-3.02 standard is necessary and mandatory the exposure and contamination levels control in the areas of handling of unsealed sources. The goal of the work is to establish how often the monitoring should be done through the survey of the contamination and exposure levels, in areas designed to manipulate 32 P and how this monitoring can contribute to the improvement the conditions of radiological protection. From the twenty eight research laboratories registered by 'Nucleo de Protecao Radiologica' (NPR) were selected four where the activities are not restrict to 32 P biological assays. The levels of contamination and exposure were evaluated using monitors GM and the layout of laboratories containing the points to be tracker defined based on the researchers' routine. At each point three values were obtained to measure the rate of contamination on the surface and exposure rate. The measures were made twice a week before and after the radioisotope manipulation. Based on these data was possible to establish the range from 0,306 to 0,678 Bq.cm -2 as operational average level to the superficial contamination. The average exposure rate measured was 5.16 n C/Kg.h. The results were important to demonstrating to researchers how they can contribute to the improvement of radiological protection conditions. (author)

  2. Monitoring bacterial faecal contamination in waters using multiplex ...

    African Journals Online (AJOL)

    Monitoring of sanitary quality or faecal pollution in water is currently based on quantifying some bacterial indicators such as Escherichia coli and faecal enterococci. Using a multiplex real-time PCR assay for faecal enterococci and Bacteroides spp., the detection of faecal contamination in non-treated water can be done in a ...

  3. Mobile means for the monitoring of atmospheric contamination in a reactor building

    International Nuclear Information System (INIS)

    Marques, S.; Lestang, M.

    2009-01-01

    After having evoked the context and challenges of contamination monitoring when exploiting nuclear reactors, the authors discuss the representativeness of the atmospheric contamination measurement as it depends on the different physicochemical forms of radionuclides present in the circuits. They indicate the different gaseous or aerosol radioactive elements which are monitored within EDF installations. They discuss the incorporation of monitoring means at the installation design level, briefly present the use of beacons inside and outside the reactor building. They describe how monitoring is organized on the basis of alert threshold adjustments: an investigation threshold and an evacuation threshold. They discuss the beacon (or sensor) selection and indicate recommendations for their implementation for optimization purposes. They indicate where these beacons are installed and evoke the experimentation of networked mobile beacons with data remote transmission

  4. Development of a calibration system for surface contamination monitors

    International Nuclear Information System (INIS)

    Marechal, M.H.H.; Barbosa, M.P.

    1992-01-01

    A calibration system for surface contamination monitors is developed, aiming supply the existence demand of these instruments. A experimental arrangement and a methodology are described. The advantages of use this system for calibration routine optimization are also discussed. (C.G.C.)

  5. Analyses of integrated aircraft cabin contaminant monitoring network based on Kalman consensus filter.

    Science.gov (United States)

    Wang, Rui; Li, Yanxiao; Sun, Hui; Chen, Zengqiang

    2017-11-01

    The modern civil aircrafts use air ventilation pressurized cabins subject to the limited space. In order to monitor multiple contaminants and overcome the hypersensitivity of the single sensor, the paper constructs an output correction integrated sensor configuration using sensors with different measurement theories after comparing to other two different configurations. This proposed configuration works as a node in the contaminant distributed wireless sensor monitoring network. The corresponding measurement error models of integrated sensors are also proposed by using the Kalman consensus filter to estimate states and conduct data fusion in order to regulate the single sensor measurement results. The paper develops the sufficient proof of the Kalman consensus filter stability when considering the system and the observation noises and compares the mean estimation and the mean consensus errors between Kalman consensus filter and local Kalman filter. The numerical example analyses show the effectiveness of the algorithm. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  6. Micro GC's for Contaminant Monitoring in Spacecraft Air, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to create new gas chromatographs (GCs) for contaminant monitoring in spacecraft air that do not require any reagents or special...

  7. Environmental monitoring of Columbia River sediments: Grain-size distribution and contaminant association

    Energy Technology Data Exchange (ETDEWEB)

    Blanton, M.L.; Gardiner, W.W.; Dirkes, R.L.

    1995-04-01

    Based on the results of this study and literature review, the following conclusions can be made: Sediment grain size and TOC (total organic carbon) influence contaminant fate and transport (in general, sediments with higher TOC content and finer grain-size distribution can have higher contaminant burdens than sediments from a given river section that have less TOC and greater amounts of coarse-grained sediments). Physiochemical sediment characteristics are highly variable among monitoring sites along the Columbia River. Sediment grain characterization and TOC analysis should be included in interpretations of sediment-monitoring data.

  8. Environmental monitoring of Columbia River sediments: Grain-size distribution and contaminant association

    International Nuclear Information System (INIS)

    Blanton, M.L.; Gardiner, W.W.; Dirkes, R.L.

    1995-04-01

    Based on the results of this study and literature review, the following conclusions can be made: Sediment grain size and TOC (total organic carbon) influence contaminant fate and transport (in general, sediments with higher TOC content and finer grain-size distribution can have higher contaminant burdens than sediments from a given river section that have less TOC and greater amounts of coarse-grained sediments). Physiochemical sediment characteristics are highly variable among monitoring sites along the Columbia River. Sediment grain characterization and TOC analysis should be included in interpretations of sediment-monitoring data

  9. Monitoring of Water and Contaminant Migration at the Groundwater-Surface Water Interface

    Science.gov (United States)

    2008-08-01

    seepage is occurring in a freshwater lake environment and to map the lateral extent of any subsurface contamination at the groundwater –surface water ...and Contaminant Migration at the Groundwater -Surface Water Interface August 2008 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public...4. TITLE AND SUBTITLE Monitoring of Water and Contaminant Migration at the Groundwater -Surface Water Interface 5a. CONTRACT NUMBER 5b. GRANT NUMBER

  10. HFS-II hands and feet contamination monitor for α, β

    International Nuclear Information System (INIS)

    Du Xiangyang; Han Shuping; Wang Xiaodong; Fan Liya; Zhang Yong; Rao Xianming; Fang Jintu

    1999-11-01

    HFS-II Hands and Feet Contamination Monitor for α, β is a necessary device which monitors the entrance of controlling area of nuclear power plant and nuclear facility, and it consists of nuclear detector, nuclear electronic circuit, computer data processing and controlling divisions, input/output controlling etc. Physical indicators conform to the requirements of relative national standard GB8703-87 and department standard EJ/T586

  11. The Development of a Sub-Surface Monitoring System for Organic Contamination in Soils and Groundwater

    Directory of Open Access Journals (Sweden)

    Sharon L. Huntley

    2002-01-01

    Full Text Available A major problem when dealing with environmental contamination is the early detection and subsequent surveillance of the contamination. This paper describes the potential of sub-surface sensor technology for the early detection of organic contaminants in contaminated soils, sediments, and landfill sites. Rugged, low-power hydrocarbon sensors have been developed, along with a data-logging system, for the early detection of phase hydrocarbons in soil. Through laboratory-based evaluation, the ability of this system to monitor organic contamination in water-based systems is being evaluated. When used in conjunction with specific immunoassays, this can provide a sensitive and low-cost solution for long-term monitoring and analysis, applicable to a wide range of field applications.

  12. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites

  13. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites.

  14. First Results from Contamination Monitoring with the WFC3 UVIS G280 Grism

    Science.gov (United States)

    Rothberg, B.; Pirzkal, N.; Baggett, S.

    2011-11-01

    The presence of contaminants within the optical light path of the instrument or telescope can alter photometric zeropoints and the observed flux levels of imaging and spectra, particularly at UV wavelengths. Regular monitoring of a spectro-photometric standard star using photometric filters has been used in the past to monitor the presence of contaminants and (when necessary) re-calibrate zeropoints. However, the use of the WFC3 UVIS Grism mode (G280 filter) may provide a more robust early alert detection system for the presence of contaminants, in particular, those that are photo-polymerized from the bright Earth. These contaminants may collect on surfaces in the optical light path of the telescope. The G280 grism is sensitive to light at wavelengths below the cutoff of the bluest UV filter (F218W). In this ISR, we present: 1) the first results from G280 monitoring for the period of 2010-November through 2011-August; 2) the discovery of an anomaly in the WCS header information of sub-array exposures; and 3) an outline for reducing standard G280 grism observations and the specialized case of observations obtained in sub-array mode.

  15. Monitoring of raptors and their contamination levels in Norway.

    Science.gov (United States)

    Gjershaug, Jan Ove; Kålås, John Atle; Nygård, Torgeir; Herzke, Dorte; Folkestad, Alv Ottar

    2008-09-01

    This article summarizes results from raptor monitoring and contamination studies in Norway of the golden eagle, gyrfalcon, white-tailed sea eagle, osprey, peregrine, and merlin. Golden eagle and gyrfalcon populations have been monitored since 1990 as part of the "Monitoring Programme for Terrestrial Ecosystems" (TOV). No long-term trend in the population size or productivity of golden eagle has been shown in any of the 5 study areas. The reproductive output of gyrfalcon is monitored in 3 areas. It is positively correlated with the populations of its main prey species, the rock ptarmigan and the willow ptarmigan. The white-tailed sea eagle population has been monitored since 1974 by the Norwegian Ornithological Society, and the population is increasing. The levels of pesticides and polychlorinated biphenyls are low in the eggs of both the golden eagle and the gyrfalcon, but elevated levels and effects on reproduction have been indicated for a coastal subpopulation of golden eagle. The pollutant levels in white-tailed sea eagle are lower than in the Baltic population of sea eagles, and shell thinning was never severe overall, but individual eggs have contained pollutant concentrations above critical levels. The levels of pollutants in the bird-eating falcons, peregrine, and merlin were higher than in other species. New emerging pollutants, like brominated diphenylethers and perfluorinated organic compounds, could be detected in all species. By incorporating available published and unpublished data, we were able to produce time trends for pollutants and shell thickness over 4 decades.

  16. Applicability of monitored natural attenuation at radioactively contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-01-15

    The IAEA attaches great importance to the dissemination of information that can assist Member States with the development, implementation, maintenance and continuous improvement of systems, programmes and activities that support a sustainable nuclear fuel cycle and nuclear applications, including managing the legacy of past practices and accidents. Hence, the IAEA has initiated a comprehensive programme of work covering all aspects of environmental remediation including: - Technical and non-technical factors influencing decision making in environmental remediation; - Site characterization techniques and strategies; - Assessment of remediation technologies; - Assessment of technical options for cleanup of contaminated media; - Post-restoration compliance monitoring; - Assessment of the costs of remediation measures. It has been observed that many measures to remove or contain contamination are inefficient below certain concentrations, in general costly, and of a limited lifetime compared with the half-lives of the radionuclides concerned. Dispersed low level contamination poses a particular challenge to those charged with its remediation. Economic considerations in many Member States also result in constraints being placed on resources available to deal with such contamination. Experience has also shown that many techniques are not efficient below certain concentration thresholds or may entail impacts on certain environmental compartments in addition to those due to the contamination itself. This includes doses received by workers on the remediation project. As a result, the concept of relying on geological media to retain contaminants and/or to 'flatten out' concentration/dose peaks is increasingly being discussed in a remediation context. Technical Reports Series No. 424 (Remediation of Sites with Dispersed Radioactive Contamination) examined a variety of technological options for remediating dispersed contamination and concluded that the approaches can be broadly

  17. Applicability of monitored natural attenuation at radioactively contaminated sites

    International Nuclear Information System (INIS)

    2006-01-01

    The IAEA attaches great importance to the dissemination of information that can assist Member States with the development, implementation, maintenance and continuous improvement of systems, programmes and activities that support a sustainable nuclear fuel cycle and nuclear applications, including managing the legacy of past practices and accidents. Hence, the IAEA has initiated a comprehensive programme of work covering all aspects of environmental remediation including: - Technical and non-technical factors influencing decision making in environmental remediation; - Site characterization techniques and strategies; - Assessment of remediation technologies; - Assessment of technical options for cleanup of contaminated media; - Post-restoration compliance monitoring; - Assessment of the costs of remediation measures. It has been observed that many measures to remove or contain contamination are inefficient below certain concentrations, in general costly, and of a limited lifetime compared with the half-lives of the radionuclides concerned. Dispersed low level contamination poses a particular challenge to those charged with its remediation. Economic considerations in many Member States also result in constraints being placed on resources available to deal with such contamination. Experience has also shown that many techniques are not efficient below certain concentration thresholds or may entail impacts on certain environmental compartments in addition to those due to the contamination itself. This includes doses received by workers on the remediation project. As a result, the concept of relying on geological media to retain contaminants and/or to 'flatten out' concentration/dose peaks is increasingly being discussed in a remediation context. Technical Reports Series No. 424 (Remediation of Sites with Dispersed Radioactive Contamination) examined a variety of technological options for remediating dispersed contamination and concluded that the approaches can be broadly

  18. Evaluation of the RSG-GAS Alpha-Beta Aerosol Contaminant Monitor Performance Under Reactor Operation Condition

    International Nuclear Information System (INIS)

    Hartoyo, Unggul; Setiawanto, Anto; Sumarno, Yulius

    2000-01-01

    Analysis to evaluate the RSG-GAS alpha-beta aerosol contaminant monitor performance was done. The high potential radiation working area such as in RSG-GAS is important to monitored for personal safety. Further it is necessary to assure that the system monitor is reliable enough under normal conditions as well as emergency condition. The method uses in this analysis are monitoring and comparing with the standard source. The standard course indicator and panel in main control room indicate that the result is 1 x 110 exp 9 Ci/m exp 3. Based on data monitor observation, the RSG-GAS alpha-beta aerosol contaminant monitor system under reactor operation condition has a good enough performance

  19. Body-surface contamination monitoring preparatory to monitoring for internal contamination

    International Nuclear Information System (INIS)

    Schlueter, W.; Klucke, H.

    1980-01-01

    Measurements in the whole-body counter of the SAAS are routinely preceded by a thorough inspection of the patients for body-surface contamination to protect the sensitive counting equipment against becoming contaminated and to avoid a falsified indication of incorporated radionuclides. The measuring system employed for these examinations is described. (author)

  20. Nuclear electronic components of surface contamination monitor based on multi-electrode proportional counter

    International Nuclear Information System (INIS)

    Du Xiangyang; Zhang Yong; Han Shuping; Rao Xianming; Fang Jintu

    2001-01-01

    The nuclear electronic components applying in Portal Monitor and Hands and Feet Surface Contamination Monitor were based on modern integrated circuit are introduced. The detailed points in circuit design and manufacturing technique are analyzed

  1. Rapid monitoring for transuranic contaminants during buried waste retrieval

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Shaw, P.G.; Randolph, P.D.; Amaro, C.R.; Pawelko, R.J.; Thompson, D.N.; Loomis, G.G.

    1991-03-01

    This document reports results of research performed in support of possible future transuranic waste retrieval operations at the Idaho National Engineering Laboratory Radioactive Waste Management Complex. The focus of this research was to evaluate various methods of performing rapid and, as much as possible, ''on-line'' quantitative measurements of 239 Pu or 241 Am, either as airborne or loose contamination. Four different alpha continuous air monitors were evaluated for lower levels of detection of airborne 239 Pu. All of the continuous air monitors were evaluated by sampling ambient air. In addition, three of the continuous air monitors were evaluated by sampling air synthetically laden with clean dust and dust spiked with 239 Pu. Six methods for making quantitative measurements of loose contamination were investigated. They were: (1) microwave digestion followed by counting in a photon electron rejecting alpha liquid scintillation spectrometer, (2) rapid radiochemical separation followed by alpha spectrometry, (3) measurement of the 241 Am 59 keV gamma ray using a thin window germanium detector, (4) measurement of uranium L-shell x-rays, (5) gross alpha counting using a large-area Ag activated ZnS scintillator, and (6) direct counting of alpha particles using a large-area ionization chamber. 40 refs., 42 figs., 24 tabs

  2. Quantitative analysis of education effect by the number of contamination in an unsealed radioisotope facility

    International Nuclear Information System (INIS)

    Matsuda, Naoki; Yoshida, Masahiro; Takao, Hideaki; Kaneko, Mamoru; Yamaguchi, Yukiko; Okumura, Yutaka

    2002-01-01

    The educational program for radiation workers is essential for the safety of radiation facility that stands on radiation protection practice by each worker. However, there appears no distinct criterion for quantitative evaluation of the education effect on radiation safety. The effectiveness of education was assessed by the number and the frequency (number of contamination/number of users) of contamination, a major incident involving radioactive materials, based on the long-term contamination surveillance data from 1996 to 2001 in Nagasaki University Radioisotope Center. Facility staffs monitored contamination in the facility every day. In 1996 and 1997, the yearly total number and the frequency of contamination found in a molecular biology room, a most frequently-used laboratory, were 150 and 1.21, respectively. The improvement of education program, including introduction of technical procedures to avoid contamination in molecular biological experiments, pre-entry instruction for fresh workers to demonstrate radiation safety practices on site, and spreading the new concept 'contamination happens by all means' through the radiation workers, markedly reduced both the number and the frequency of contamination to 33 and 0.48, respectively. This reduction seemed to be attributable for two different reasons; improvement of skills to avoid contamination, and thorough execution of monitoring and decontamination. These results suggested that contamination was a possible criterion for evaluating effectiveness of education program for radiation workers. (author)

  3. Radioactivity monitoring and import regulation of the contaminated foodstuffs in Japan following the Chernobyl nuclear power plant accident

    International Nuclear Information System (INIS)

    Izumo, Yoshiro

    1997-01-01

    Radioactivity monitoring and import regulation of the contaminated foodstuffs executed by Minstry of Health and Welfare following the Chernobyl nuclear plant accident were reviewed as follows; 1) background of socio-psychological effects and environmental radioactivity leading to the regulation (to may 3, 1986); 2) intial intervention for imported foodstuffs in Japan (may 8, '86), and 3) in european countries (to may 31, '86), immediately after the Accident, respectively; 4) determination of the interim driven intervention level for radionuclides in imported foodstuffs (( 134 Cs + 137 Cs): 370 Bq/Kg) and activation of the monitoring, 5) outline of the monitoring with elapsed time, number of foodstuffs monitored, number of foodstuffs exceeded radioactivity of the intervention level and re-exported; 6) guideline in international trade of radioactive contaminated foodstuffs adopted by CODEX Alimentarius Commission (FAO/WHO) and the intervention level recommended by ICRP following the Accident; 7) discussion for problems and scopes in future based on the results of monitoring. As the results, a number of imported foodstuffs (about 75,000 samples at present) has been monitored, 55 samples exceeding the interim intervention level were re-exported to each export's country, and socio-psychological doubts for radioactive contamination of imported foodstuffs have been dispersed. In addition, problems for several factors based on calculation of the interim intervention level, radioactivity level of foodstuffs exceeding about 50 Bq/Kg as radiocesiums and necessity of monitoring for the other radionuclides in foods except radiocesiums were also discussed. (author)

  4. Radioactivity monitoring and import regulation of the contaminated foodstuffs in Japan following the Chernobyl nuclear power plant accident

    Energy Technology Data Exchange (ETDEWEB)

    Izumo, Yoshiro [Institute of Public Health, Tokyo (Japan)

    1997-03-01

    Radioactivity monitoring and import regulation of the contaminated foodstuffs executed by Minstry of Health and Welfare following the Chernobyl nuclear plant accident were reviewed as follows; (1) background of socio-psychological effects and environmental radioactivity leading to the regulation (to may 3, 1986); (2) intial intervention for imported foodstuffs in Japan (may 8, `86), and (3) in european countries (to may 31, `86), immediately after the Accident, respectively; (4) determination of the interim driven intervention level for radionuclides in imported foodstuffs (({sup 134}Cs + {sup 137}Cs): 370 Bq/Kg) and activation of the monitoring, (5) outline of the monitoring with elapsed time, number of foodstuffs monitored, number of foodstuffs exceeded radioactivity of the intervention level and re-exported; (6) guideline in international trade of radioactive contaminated foodstuffs adopted by CODEX Alimentarius Commission (FAO/WHO) and the intervention level recommended by ICRP following the Accident; (7) discussion for problems and scopes in future based on the results of monitoring. As the results, a number of imported foodstuffs (about 75,000 samples at present) has been monitored, 55 samples exceeding the interim intervention level were re-exported to each export`s country, and socio-psychological doubts for radioactive contamination of imported foodstuffs have been dispersed. In addition, problems for several factors based on calculation of the interim intervention level, radioactivity level of foodstuffs exceeding about 50 Bq/Kg as radiocesiums and necessity of monitoring for the other radionuclides in foods except radiocesiums were also discussed. (author)

  5. Requirements for internal contamination monitoring units

    International Nuclear Information System (INIS)

    Werner, E.; Beyer, D.; Doerfel, H.; Erlenbach, H.; Fischbach, G.; Henrichs, K.; Keller, K.D.; Koenig, K.; Riedel, W.; Scheler, R.; Schieferdecker, H.

    1994-01-01

    For the evaluation of internal contamination by officially authorized monitoring units according to section 63 (6) of the German radiation protection ordinance, a directive will be prepared in order to define uniform requirements for the laboratories in charge of incorporation monitoring by appointment of the relevant authorities. These requirements refer to equipment, to performance of measurements, to interpretation of measured values, to quality control as well as to documentation and to delivery of results. The duties of such laboratories comprise measurements of radioactivity, evaluation of intakes of radionuclides and of the resulting internal radiation dose, but also transmission of results to the employer, to the central dose registry, and under certain circumstances to the authorities. Among the requirements to be met by the laboratory for incorporation control are a sufficient measuring efficiency, the implementation of in-house checks, and the participation in intercomparison programs. For the accomplishment of such duties the laboratory needs appropriate apparatus, rooms, facilities, and staffing. (orig.) [de

  6. Unregulated Contaminant Monitoring Rule 3 (UCMR 3), (2013-2015) Occurrence Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — The third Unregulated Contaminant Monitoring Rule (UCMR 3), conducted under EPA oversight, was published in the Federal Register on May 2, 2012. UCMR 3 requires...

  7. Radioisotope studies of some effects and interactions of trace contaminants

    International Nuclear Information System (INIS)

    1976-01-01

    The coordinated programme of ''isotopic tracer-aided studies of the biological side-effects of foreign chemical residues in food and agriculture'', initiated in 1973, had involved the participation of 12 scientists from 10 countries. Pesticide residues, toxic metals, atmospheric sulphur dioxide were studied, and the use of radiotracer techniques as monitoring tools for existing contaminant levels or for their biological effects. The programme had been successful in the development and application of selected labelled substrate techniques. Specific aspects studied were the effects of environmental contaminants at the molecular level of the cell nucleus, the development and significance of radioimmunoassay procedure for trace contaminants, action and joint action of toxic elements, and the radiometric analysis of cholinesterase as an index of exposure to organophosphorus and carbamate pesticides. Ten papers were presented and 12 coordinated investigations discussed. A number of recommendations were made

  8. Comparison of two freshwater turtle species as monitors of radionuclide and chemical contamination: DNA damage and residue analysis

    International Nuclear Information System (INIS)

    Meyers-Schoene, L.; Shugart, L.R.; Beauchamp, J.J.; Walton, B.T.

    1993-01-01

    Two species of turtles that occupy different ecological niches were compared for their usefulness as monitors of freshwater ecosystems where both low-level radioactive and nonradioactive contaminants are present. The pond slider (Trachemys scripta) and common snapping turtle (Chelydra serpentina) were analyzed for the presence of 90 Sr, 137 Cs, 60 Co, and Hg, radionuclides and chemicals known to be present at the contaminated site, and single-strand breaks in liver DNA. The integrity of the DNA was examined by the alkaline unwinding assay, a technique that detects strand breaks as a biological marker of possible exposure to genotoxic agents. This measure of DNA damage was significantly increased in both species of turtles at the contaminated site compared with turtles of the same species at a reference site, and shows that contaminant-exposed populations were under more severe genotoxic stress than those at the reference site. The level of strand breaks observed at the contaminated site was high and in the range reported for other aquatic species exposed to deleterious concentrations of genotoxic agents such as chemicals and ionizing radiation. Statistically significantly higher concentrations of radionuclides and Hg were detected in the turtles from the contaminated area. Mercury concentrations were significantly higher in the more carnivorous snapping turtle compared with the slider; however, both species were effective monitors of the contaminants

  9. Statistical considerations in practical contamination monitoring

    International Nuclear Information System (INIS)

    Brodsky, A.; Gallaghar, R.G.

    1991-01-01

    This paper reports on an examination of smear survey practices which indicates that many radiation safety programs are lacking in important aspects of contamination monitoring. In order to satisfy regulatory and potential litigatory requirements, smear surveys should include the measurement and recording of the flowing data: area of each smear and smear procedure (by reference); total counts on smear and counting procedure; total counts on appropriate blanks and description of blank; total counts on standard and specifications of standard; and all counting times. The rationale for these smear survey requirements is obtained by examining the formulation of the minimum detectable amount (MDA) on a smear

  10. Present state of the monitoring for internal contamination at Tokai Research Establishment, Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Akaishi, J.; Fukuda, H.; Mizushita, S.

    1980-01-01

    Results are presented of internal contamination surveys carried out since 1969 at Tokai Research Establishment. Routine monitoring sometimes revealed significant internal contamination for tritium workers, but almost never for others. The number of subjects for special monitoring varied according to the activities. In 1965, the number of subjects for special monitoring was nearly 300, due to a reactor repair that year. In recent years, the number or special monitoring has been several tens or so. With regard to special monitoring, the workers with significant internal contamination were less than 50%. The internal dose (50 years) estimated for the majority of subjects was of mrem order. During the past 15 years, only several cases of exposure of rem order were found. The highest dose experienced was about 4 rems ( 131 I thyroid) (U.K.)

  11. Detection and Monitoring of E-Waste Contamination through Remote Sensing and Image Analysis

    Science.gov (United States)

    Garb, Yaakov; Friedlander, Lonia

    2015-04-01

    Electronic waste (e-waste) is one of today's fastest growing waste streams, and also one of the more problematic, as this end-of-life product contains precious metals mixed with and embedded in a variety of low value and potentially harmful plastic and other materials. This combination creates a powerful incentive for informal value chains that transport, extract from, and dispose of e-waste materials in far-ranging and unregulated ways, and especially in settings where regulation and livelihood alternatives are sparse, most notably in areas of India, China, and Africa. E-waste processing is known to release a variety of contaminants, such as heavy metals and persistent organic pollutants, including flame retardants, dioxins and furans. In several sites, where the livelihoods of entire communities are dependent on e-waste processing, the resulting contaminants have been demonstrated to enter the hydrological system and food chain and have serious health and ecological effects. In this paper we demonstrate for the first time the usefulness of multi-spectral remote sensing imagery to detect and monitor the release and possibly the dispersal of heavy metal contaminants released in e-waste processing. While similar techniques have been used for prospecting or for studying heavy metal contamination from mining and large industrial facilities, we suggest that these techniques are of particular value in detecting contamination from the more dispersed, shifting, and ad-hoc kinds of release typical of e-waste processing. Given the increased resolution and decreased price of multi-spectral imagery, such techniques may offer a remarkably cost-effective and rapidly responsive means of assessing and monitoring this kind of contamination. We will describe the geochemical and multi-spectral image-processing principles underlying our approach, and show how we have applied these to an area in which we have a detailed, multi-temporal, spatially referenced, and ground

  12. Present state of the monitoring for internal contamination at Tokai Research Establishment, Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Akaishi, J.; Fukuda, H.; Mizushita, S.

    1980-01-01

    At Tokai Research Establishment, JAERI, over one thousand people work in hot areas such as reactors, accelerators, chemical laboratories and waste treatment plants. The monitoring for internal contamination of this personnel is presented. Routine and special monitoring are carried out. The object of the former is to check for the presence of significant contamination, and that of the latter is to estimate body burden and committed dose equivalent, if necessary. Heavy shield and shadow shield whole body counters, a low energy lung counter and a wound monitor are used to detect the internal contamination due to γ or chi ray emitters, and bioassay technique is used for α or β emitters and uranium. The results of the monitoring until now are presented. (H.K.)

  13. Response of monitors of surface contamination to internal exposition control from 131I in the 'nuclear medicine services'

    International Nuclear Information System (INIS)

    Puerta, Nancy; Rojo, Ana M.; Villella, Adrian; Gossio, Sebastian; Parada, Ines Gomez; Acosta, Norma; Arenas, German

    2013-01-01

    The IAEA, in its publication RS-G-1.2, proposes individual control of workers occupationally exposed with risk of internal exposure when the potential exposure provided by incorporation leads to a value of annual committed effective dose equal to or greater than 1 mSv. Because the radionuclide 131 I is the most important to control internal exposure in Nuclear Medicine Services, it is evaluated if the surface contamination monitors, commonly used in nuclear medicine centers of Argentina, would implement individual control of internal exposure to 131 I. Selected detectors were calibrated with a dummy neck and thyroid with calibrated sources of 131 I and 133 Ba reference. For each detector is was estimated the detection efficiency for 131 I and its detection limit. Each instrument was evaluated for the lowest effective dose possible to detect compromised by individual routine monitoring with different measurement intervals . We analyzed the response of each team for determining conditions that may be effective for the control of internal exposure of 131 I. Finally , we conclude that the daily individual monitoring surface contamination detectors available in the Nuclear Medicine Services is feasible to implement and ensures detection of significant additions of 131 I

  14. Contaminant monitoring programmes using marine organisms: Quality assurance and good laboratory practice

    International Nuclear Information System (INIS)

    1990-01-01

    This publication provides guidelines for obtaining reliable and relevant data during monitoring programmes in which contaminants are measured in marine organisms. It describes the precautions to be taken in each of the procedural steps from planning and sampling to the publication of data reports. The purpose of this document is to provide general guidance on quality assurance and to outline the approach that could be taken by laboratories to achieve the specific aims(s) for each marine pollution monitoring programme. Since most laboratories are currently focussing on programmes involving marine organisms, this document will be confined to this aspect. Four main aims can be identified for programmes involving the collection and analysis of marine organisms for the three main groups of contaminants (metals, organochlorine compounds and petroleum hydrocarbons), these are: (i) The measurement of contaminant levels in edible marine organisms in relation to public health; (ii) The identification of heavily contaminated areas of the sea (''hot spots'') where levels of contaminants are at least an order of magnitude higher than levels in clean or uncontaminated areas; (iii) The establishment of present levels of contaminants in marine organisms (i.e., a ''baseline''); (iv) The assessment of changes in concentrations of contaminants in organisms over a period of time (trends). The selection of organisms will be dictated by the eating patterns of the population. These can be identified by a survey of the species sold at the market, by obtaining information from colleagues in government departments who deal with such matters or in the absence of such information, by distributing a questionnaire to a representative section of the general public. 9 refs, 4 figs

  15. Contaminant Effects on California Bay–Delta Species and Human Health

    Directory of Open Access Journals (Sweden)

    Stephanie Fong

    2016-12-01

    Full Text Available doi: https://doi.org/10.15447/sfews.2016v14iss4art5Many contaminants in the California Bay–Delta (Bay–Delta exceed regulatory standards, affect aquatic species, and potentially affect human health. Recent studies provide multiple lines of evidence that contaminants affect species of concern in the Bay–Delta (e.g., the decline of several important fish species referred to as the “Pelagic Organism Decline” or POD. Contaminants occur as dynamic complex mixtures and exert effects at multiple levels of biological organization. Multiple chemicals impair processes at cellular and physiological levels (measured as growth, development, and behavior abnormalities, and when viability and reproductive output are affected, populations are affected. As an important example, the population decline of the endangered Delta Smelt (Hypomesus transpacificus is significantly associated with multiple stressors, including insecticide use. New analyses presented in this paper show significant correlations between pyrethroid use and declining abundance of POD fish species. Water sampled from the Bay–Delta causes multiple deleterious effects in fish, and Delta Smelt collected from the Bay–Delta exhibit contaminant effects. Fish prey items are also affected by contaminants; this may have an indirect effect on their populations. Co-occurrence with thermal changes or disease can exacerbate contaminant effects. Contaminants also pose threats to human health via consumption of fish and shellfish, drinking water, and contact recreation, in particular, mercury, cyanobacteria toxins, disinfection byproducts, pathogens, pesticides, and pharmaceuticals and personal care products. The role of contaminants in the decline of Bay–Delta species is difficult to accurately assess in a complex, dynamic system. However, tools and approaches are available to evaluate contaminant effects on Bay–Delta species, and separate the effects of multiple stressors. Integrated

  16. Development and application of techniques for monitoring the bioremediation of petroleum hydrocarbon-contaminated soils

    International Nuclear Information System (INIS)

    Greer, C.; Hawar, J.; Samson, R.

    1994-01-01

    A series of tests was designed to examine bioremediation potential in soil and to monitor performance during the treatment operation. Physical and chemical characterization of the soil provides information on the types of organics, their concentrations, and whether interfering materials are present. Microbiological assessment involves culturing of bacterial populations in the soil and examination of the colonies to determine which have the genetic potential to degrade the soil contaminants. Catabolic gene probes are used to survey viable bacteria from petroleum hydrocarbon contaminated soils. Such soils consistently demonstrate the presence of bacteria possessing the genetic capability to degrade simple straight-chain alkanes and aromatics. Mineralization and respirometric studies are indicators of the biological activity in the soil, and can be directed at microbial activity towards specific substrates. Gene probe monitoring of a petroleum hydrocarbon contaminated soil during biopile treatment demonstrated that hydrocarbon-degrading bacterial numbers and activity were temperature dependent. The results showed that the activity of the indigenous bacteria as measured by hexadecane mineralization also correlated with the disappearance of the oil and grease. The application of this protocol has provided a useful means to screen contaminated soils for bacteria with desirable catabolic properties and to monitor pollutant-degrading bacteria during biotreatment. 15 refs., 10 figs

  17. Monitoring of plutonium contaminated solid waste streams. Chapter IV: Passive neutron assay

    International Nuclear Information System (INIS)

    Birkhoff, G.; Bondar, L.

    1978-01-01

    The fundamentals of the passive neutron technique for the non destructive assay of plutonium bearing materials are summarized. A reference monitor for the passive neutron assay of Pu contaminated solids is described in terms of instrumental design principles and performances. The theoretical model of this reference monitor with pertinent nuclear data and functions for the interpretation of experimental data is given

  18. EFFECT OF DIESEL CONTAMINATION ON CAPACITANCE VALUES OF CRUDE PALM OIL

    Directory of Open Access Journals (Sweden)

    C. H. FIZURA

    2014-06-01

    Full Text Available Measurement of crude palm oil (CPO contamination is a major concern in CPO quality monitoring. In this study, capacitive sensing technique was used to monitor diesel contamination levels in CPO. A low cost capacitive sensing system was developed by using AD7746 capacitance to digital converter. The capacitance value of CPO samples with different contamination levels (v/v% ranged from 0% to 50% was collected at a room temperature (25°C. The objective of this study is to find a relationship between capacitance values and diesel contamination levels in CPO. The results showed that capacitance value decreased as the diesel contamination levels increased. For the 0% to 50% contamination range, the regression equation was y = 0.0002x2 - 0.0125x + 0.936 with R2 value of 0.96. For the 0% to 10% contamination range (where the percentage was the representative of potential contaminations levels found in CPO the correlation equation was y = -0.02x + 0.95 with R2 value of 0.95. These results indicated that capacitive sensing technique has potential for CPO quality monitoring.

  19. Evaluation of sensitivity evaluation of a contamination monitor for use in monitoring of internal exposure of workers in nuclear medicine

    International Nuclear Information System (INIS)

    Dantas, Bernando Maranhao; Assis, Janima Cruz de; Oliveira, Salomao Marques de; Dantas, Ana Leticia Almeida

    2014-01-01

    In practice of nuclear medicine, expert personnel routinely handle radiopharmaceuticals for diagnosis and radiotherapy. The control of intakes of radionuclides by workers can be performed through internal dosimetry techniques, as an integral part of the radiation protection program of the installation. The use of radiopharmaceuticals for diagnostic and therapeutic purposes in vivo and in vitro in Brazil is regulated by CNEN-NE Standards and 3:05 CNEN-NN 3.01. The International Atomic Energy Agency (IAEA) recommends the establishment of an internal monitoring program on workers, especially those subject to possible exposure to annual effective doses greater than 1 mSv. Note that, currently, in Brazil, are not available qualified laboratories to provide internal monitoring services in all regions in the country, if it were applied by CNEN, the requirement for internal monitoring of workers. This paper presents the development of a simple and low-cost methodology for in vivo monitoring of 131 I in the thyroid. The proposed methodology is the use of portable monitor of surface contamination, equipment available and routinely used in all nuclear medicine services in Brazil. The monitor is calibrated with neck-thyroid simulator developed at the Laboratory of In Vivo Monitoring of IRD/CNEN-RJ. The equipment tested is suitable for application in in vivo occupational monitoring thyroid. This conclusion is based on the fact that the detection system has sufficient sensitivity for monitoring up to seven days after the incorporation of the radionuclide and guarantees 131 I detection in values that result in effective doses below 1 mSv for the exposure scenarios adopted

  20. Tritium contamination and monitoring at Frascati Neutron Generator

    Energy Technology Data Exchange (ETDEWEB)

    Lucci, F.; Sandri, S.; Ianni, A. [ENEA, Frascati (Italy). Dipartimento Ambiente; Vasselli, R. [ANPA, Roma (Italy); Pillon, M.; Bettinali, L. [ENEA, Frascati (Italy). Dipartimento Energia

    1994-11-01

    The Frascati Neutron Generator (FGN) is a specialised 300 keV, 3 mA direct electrostatic deuteron accelerator which produces about 5-10{sup 1}1 14 MeV neutrons per second by D-T reactions on a tritium-titanium fixed target. This paper concerns the tritium contamination control and monitoring aspects after some months of testing and a preliminary period of operation of the plant. The tritium monitoring system is composed of both on-line and off-line devices to control the tritium concentration in the atmosphere measured from different parts of the plant: vacuum exhaust clean up (VECU) system, stack, etc. The on-line devices are three flux monitors, that sample continuosly the air from up to eight different points in the plant. The passive sampling system is designed to select the chemical form of tritium and to collect respectively HTO and HT in two different cartridges filled with an appropriate drying material. The response of the on-line tritium monitor system are exposed and discussed: some measurements performed with atmosphere dehumidifying apparatus of this system are described and the relevant results are analysed.

  1. Tritium contamination and monitoring at Frascati Neutron Generator

    International Nuclear Information System (INIS)

    Lucci, F.; Sandri, S.; Ianni, A.; Pillon, M.; Bettinali, L.

    1994-11-01

    The Frascati Neutron Generator (FGN) is a specialised 300 keV, 3 mA direct electrostatic deuteron accelerator which produces about 5-10 1 1 14 MeV neutrons per second by D-T reactions on a tritium-titanium fixed target. This paper concerns the tritium contamination control and monitoring aspects after some months of testing and a preliminary period of operation of the plant. The tritium monitoring system is composed of both on-line and off-line devices to control the tritium concentration in the atmosphere measured from different parts of the plant: vacuum exhaust clean up (VECU) system, stack, etc. The on-line devices are three flux monitors, that sample continuosly the air from up to eight different points in the plant. The passive sampling system is designed to select the chemical form of tritium and to collect respectively HTO and HT in two different cartridges filled with an appropriate drying material. The response of the on-line tritium monitor system are exposed and discussed: some measurements performed with atmosphere dehumidifying apparatus of this system are described and the relevant results are analysed

  2. Optimization of monitoring sewage with radionuclide contaminants. Optimizatsiya kontroya stochnykh vod, zagryaznennykh radionuklidami

    Energy Technology Data Exchange (ETDEWEB)

    Egorov, V N [Vsesoyuznyj Nauchno-Issledovatel' skij Inst. Neorganicheskikh Materialov, Moscow (Russian Federation)

    1991-03-01

    Recommendations on optimization of monitoring contaminated sewage aimed at enviromental protection agxinst radioactive contamination at minimum cost are presented. The way of selecting water sampling technique depends on water composition stability and flow rate. Depending on the type of radionuclide distribution in the sewage one can estimate minimum frequency of sampling or number of samples sufficient for assuring reliability of the conclusion on the excess or non-excess of permissible radioactive contamination levels, as well as analysis assigned accuracy. By irregular contaminated sewage-discharge and possibility of short-term releases of different form and duration, sampling should be accomplished through automatic devices of continuons or periodic operation.

  3. SoilCAM: soil contamination: advanced integrated characterisation and time-lapse monitoring

    NARCIS (Netherlands)

    French, H.K.; Zee, van der S.E.A.T.M.; Meju, M.

    2009-01-01

    The SoilCAM project is aimed at improving current methods for monitoring contaminant distribution and biodegradation in the subsurface. Currently proven methods, based on invasive sampling of soil, soil water and gaseous phase, are unable to provide sufficiently accurate data with high enough

  4. Estimating an appropriate sampling frequency for monitoring ground water well contamination

    International Nuclear Information System (INIS)

    Tuckfield, R.C.

    1994-01-01

    Nearly 1,500 ground water wells at the Savannah River Site (SRS) are sampled quarterly to monitor contamination by radionuclides and other hazardous constituents from nearby waste sites. Some 10,000 water samples were collected in 1993 at a laboratory analysis cost of $10,000,000. No widely accepted statistical method has been developed, to date, for estimating a technically defensible ground water sampling frequency consistent and compliant with federal regulations. Such a method is presented here based on the concept of statistical independence among successively measured contaminant concentrations in time

  5. Thermoexoemission detectors for monitoring radioactive contamination of industrial waste waters

    International Nuclear Information System (INIS)

    Obukhov, V.T.; Sobolev, I.A.; Khomchik, L.M.

    1987-01-01

    Detectors on base of BeO(Na) monocrystals with thermoemission to be used for monitoring radioactive contamination of industrial waste waters are suggested. The detectors advantages are sensitivity to α and low-ehergy β radiations, high mechanical strength and wide range of measurements. The main disadvantage is the necessity of working in red light

  6. Scanning personnel for internal deposition of radioactive material with personnel contamination whole body friskers and portal monitors

    International Nuclear Information System (INIS)

    Lobdell, J.L.

    1996-01-01

    The potential for using personnel contamination devices such as whole body friskers and portal monitors for internal contamination monitoring was evaluated. Internally deposited radioactive material is typically determined with whole body counting systems. Whole body counts have traditionally been performed on personnel when they report for work, on a periodic basis (i.e., annually), when an uptake is suspected, and on termination. These counts incur significant expense. The monitored personnel pass through whole body friskers and portal monitors daily. This investigation was performed to determine if the external contamination monitors could provide an alternative to the more Costly whole body counting. The ability to detect 1% of a DAC for critical radioisotopes was applied as a detection criteria for this investigation. The results of whole body counts were used to identify the typical internal contamination radionuclides. From this list, the radioisotopes that would be the most difficult to measure were identified. From this review, 60 Co and 131 I were determined to be the critical radionuclides. One percent of a DAC for each isotope was placed, one at a time, in a humanoid phantom. The phantom was placed in the whole body frisker and open-quotes countedclose quotes. The phantom was carried through the portal monitor at a speed equivalent to a person walking through the monitor. Frequency of detection was derived for both systems. Practical aspects of integrating this screening system with traditional internal dosimetry programs are discussed

  7. Shuttle on-orbit contamination and environmental effects

    Science.gov (United States)

    Leger, L. J.; Jacobs, S.; Ehlers, H. K. F.; Miller, E.

    1985-01-01

    Ensuring the compatibility of the space shuttle system with payloads and payload measurements is discussed. An extensive set of quantitative requirements and goals was developed and implemented by the space shuttle program management. The performance of the Shuttle system as measured by these requirements and goals was assessed partly through the use of the induced environment contamination monitor on Shuttle flights 2, 3, and 4. Contamination levels are low and generally within the requirements and goals established. Additional data from near-term payloads and already planned contamination measurements will complete the environment definition and allow for the development of contamination avoidance procedures as necessary for any payload.

  8. Rapid monitoring of large groups of internally contaminated people following a radiation accident

    International Nuclear Information System (INIS)

    1994-05-01

    In the management of an emergency, it is necessary to assess the radiation exposures of people in the affected areas. An essential component in the programme is the monitoring of internal contamination. Existing fixed installations for the assessment of incorporated radionuclides may be of limited value in these circumstances because they may be inconveniently sited, oversensitive for the purpose, or inadequately equipped and staffed to cope with the large numbers referred to them. The IAEA considered it important to produce guidance on rapid monitoring of large groups of internally contaminated people. The purpose of this document is to provide Member States with an overview on techniques that can be applied during abnormal or accidental situations. Refs and figs

  9. Contamination monitor as a nuclear stethoscope for community nuclear medicine

    International Nuclear Information System (INIS)

    Rehani, M.M.; Sharma, S.K.; Sharma, R.R.

    1979-01-01

    A portable contamination monitor has been modified for use as an in vivo counting probe. The evaluation by physical parameters and clinical studies shows its suitability for a variety of diagnostic studies. The correlation equations for thyroid uptake measurement have been worked out for whole range of values. Its use as a versatile nuclear stethoscope is envisaged. (author)

  10. Air contamination control as an element of state environmental monitoring

    International Nuclear Information System (INIS)

    Grabowski, D.

    1993-01-01

    The results of air contamination control on the base of gamma and beta radioactivity of aerosols collected on filters and in precipitation samples have been shown. The data have been gathered from 12 monitoring stations in Poland during 1993. No significant differences between actual results and those obtained in previous years have been noticed. 4 figs, 1 tab

  11. Development and Application of Devices for Remote Monitoring of Gamma-Ray Contamination at RECOM Ltd

    International Nuclear Information System (INIS)

    Ivanov, O.P.; Stepanov, V.E.; Chesnokov, A.V.; Sudarkin, A.N.; Urutskoev, L.I.

    1999-01-01

    Devices for remote monitoring of gamma-ray contamination develop at RECOM Ltd. are described and typical examples of their application are show. The following devices are discussed: spectrum-sensitive collimated devices for mapping of radioactivity on contaminated surfaces- scanning collimated Gamma Locator, device for field Cs-137 contamination mapping-CORAD; devices for gamma-ray imaging computer-controlled High-Energy Radiation Visualizer (HERV) and Coded Mask Imager

  12. The Opera Instrument: An Advanced Curation Development for Mars Sample Return Organic Contamination Monitoring

    Science.gov (United States)

    Fries, M. D.; Fries, W. D.; McCubbin, F. M.; Zeigler, R. A.

    2018-01-01

    Mars Sample Return (MSR) requires strict organic contamination control (CC) and contamination knowledge (CK) as outlined by the Mars 2020 Organic Contamination Panel (OCP). This includes a need to monitor surficial organic contamination to a ng/sq. cm sensitivity level. Archiving and maintaining this degree of surface cleanliness may be difficult but has been achieved. MSR's CK effort will be very important because all returned samples will be studied thoroughly and in minute detail. Consequently, accurate CK must be collected and characterized to best interpret scientific results from the returned samples. The CK data are not only required to make accurate measurements and interpretations for carbon-depleted martian samples, but also to strengthen the validity of science investigations performed on the samples. The Opera instrument prototype is intended to fulfill a CC/CK role in the assembly, cleaning, and overall contamination history of hardware used in the MSR effort, from initial hardware assembly through post-flight sample curation. Opera is intended to monitor particulate and organic contamination using quartz crystal microbalances (QCMs), in a self-contained portable package that is cleanroom-compliant. The Opera prototype is in initial development capable of approximately 100 ng/sq. cm organic contamination sensitivity, with additional development planned to achieve 1 ng/sq. cm. The Opera prototype was funded by the 2017 NASA Johnson Space Center Innovation Charge Account (ICA), which provides funding for small, short-term projects.

  13. Theoretical considerations on design and analysis of monitoring systems for Pu-contaminated solid wastes

    International Nuclear Information System (INIS)

    Notea, A.

    1979-01-01

    Monitoring systems for plutonium contaminated wastes refers to both managerial regulations and instrumental hardware. Its design is inseparable from the design of the production line in the fuel handling facility, and depends on the general wastes management program. Characteristic functions of the monitors are discussed and the necessity of reference monitors is stressed. The reference monitor enables the formation of a quality scale. Guidelines for future R and D efforts are suggested

  14. International systems for harmonization and quality control by in vivo monitoring and quality control by in vivo monitoring of internal contamination

    Energy Technology Data Exchange (ETDEWEB)

    Malatova, I [National Radiation Protection Inst., Prague (Czech Republic)

    1996-12-31

    After the Chernobyl accident, whole body counting for the monitoring of internal contamination of the population was widely used. In many cases, great discrepancy occurred between in vivo measured values and predicted ones from model calculations. This situation was very similar to the situation in environmental monitoring, however, by sample measurement, quality assurance and quality control of the measurement procedure is much easier than by whole body counting. In addition to it, unlike in environmental monitoring, use of semiconductor detectors by whole counting was rather limited in this time so there were few laboratories which were able to distinguish up to 20 radionuclides by which people from the vicinity of Chernobyl were internally contaminated. Therefore, effort was undertaken by many international organization to summarize current status of whole body counting and to estimate uncertainty and sensitivity of different devices. In this paper efforts to harmonize an interpretation of measured results is given. Whole body counting laboratory of the National Radiation Protection Institute (NRPI) in Prague participates in the above mentioned intercomparisons with good results and scientists from NRPI have participated in the preparation of 3 international recommendations concerning measurement of internal contamination (author).

  15. Monitoring of radioactive contamination in food and the environment 1986-1998

    International Nuclear Information System (INIS)

    Liland, Astrid; Skuterud, Lavrans; Bergan, Tone; Forseth, Torbjoern; Gaare, Eldar; Hellstroem, Turid

    2001-01-01

    The results from the national monitoring of radioactive contamination in food and the environment 1986-1998 are presented. The average 137Cs concentration is decreasing in cow's and goat's milk, sheep, reindeer and fresh water fish. Pasture and fungi are, on the contrary, not showing a general decreasing trend. The radioactivity in food and humans has been decreasing since 1987. The effective dose from intake is estimated to 0.02 mSv for an average Norwegian in 1998. Vulnerable groups may have received doses up to 0.4 mSv. One cannot rule out the possibility that some individuals in these groups have received doses superior to 1 mSv/year. (Author)

  16. Mussels and sediment as monitoring tools for contaminants: which to use when?

    Science.gov (United States)

    For decades, sediments and mussels have been used to assess the ecological and human health risks associated with concentrations of bioavailable organic and metal contaminants in a variety of coastal-wide and localized monitoring programs. Mussels (Mytilus edulis) bioaccumulate o...

  17. Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2015 and FY2016

    Energy Technology Data Exchange (ETDEWEB)

    Mizell, Steve A [Desert Research Inst. (DRI), Las Vegas, NV (United States); Miller, Julianne J [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, Greg [Desert Research Inst. (DRI), Las Vegas, NV (United States); Campbell, Scott A [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2017-10-01

    The Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Contamination Area (CA) as a result of storm runoff. This activity supports Nevada Nuclear Security Administration (NNSA) efforts to complete regulatory closure of the Soils Corrective Action Unit (CAU) contamination areas. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the appropriate closure design and post-closure monitoring program.

  18. Application Of The SPV-based Surface Lifetime Technique To In-Line Monitoring Of Surface Cu Contamination

    Science.gov (United States)

    D'Amico, John; Savtchouk, Alexandre; Wilson, Matthew; Kim, Chul Hong; Yoo, Hyung Won; Lee, Chang Hwan; Kim, Tae Kyoung; Son, Sang Hoon

    2009-09-01

    Implementation of Cu interconnects into Silicon Integrated Circuits (IC's) has been instrumental in the continuing improvement of IC device performance. Copper as a well known Gate Oxide Integrity (GOI) killer [1, 2] requires extensive protocols to minimize the possibility of cross contamination. Despite such protocols the risk for cross contamination exists, and consequently there is the need for in-line Cu cross-contamination detection metrology. Preferably the metrology will be non-destructive, fast, and capable of mapping on product wafers. Up to now the most common approaches for monitoring Cu contamination in IC fabrication lines either measure Cu in the bulk Si, which is not applicable to Cu cross-contamination monitoring because Back-End-of-the-Line thermal budgets restrict the ability to diffuse the surface Cu into the bulk Si; or the techniques are not optimal for in-line monitoring due to their destructive, time-consuming, or costly nature. In this work we demonstrate for the first time the application of the ac-Surface Photo Voltage (ac-SPV) surface lifetime approach [3] to in-line, full wafer coverage mapping of low level (metrology system. Furthermore, because the metrology is non-contact (utilizing edge-grip handling) and non-destructive, it is directly applicable to measurement of production wafers. In-line fab data acquired using this metrology is presented and compared to data from Inductively Coupled Plasma Mass Spectroscopy (ICP-MS).

  19. Air monitoring data reveal previously unknown contamination at radioactive waste disposal area, Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Kraig, D.H.; Conrad, R.C.

    2000-01-01

    Air monitoring at Area G, the low-level radioactive waste disposal area at Los Alamos National Laboratory, revealed increased air concentrations of 239 Pu and 241 Am at one location along the north boundary. This air monitoring location is a couple of meters north of a dirt road used to access the easternmost part of Area G. Air concentrations of 238 Pu were essentially unaffected which was puzzling because both 238 Pu and 239 Pu are present in the local, slightly contaminated soils. Air concentrations of these radionuclides increased about a factor of ten in early 1995 and remained at those levels until the first quarter of 1996. During the spring of 1996 air concentrations again increased by a factor of about ten. No other radionuclides were elevated, and no other Area G stations showed elevations of these radionuclides. After several formal meetings did not provide an adequate explanation for the elevations, a gamma-survey was performed and showed a small area of significant contamination just south of the monitor location. We found that in February 1995, a trench for a water line had been dug within a meter or so of the air stations. Then, during early 1996, the dirt road was rerouted such that its new path was directly over the unknown contamination. It appears that the trenching brought contaminated material to the surface and caused the firs rise in air concentrations and then the rerouting of the road over the contamination caused the second rise, during 1996. We also found that during 1976 and 1977 contaminated soils from the clean-up of an old processing facility had been spread over the filled pits in the vicinity of the air monitors. These soils, which were probably the source of the air contamination, were very low in 238 Pu which explains why we saw very little 238 Pu in the increased air concentrations. A layer of gravel and sand was spread over the contaminated area. Although air concentrations of 239 Pu and 241 Am dropped considerably, they have

  20. Bringing together raptor collections in Europe for contaminant research and monitoring in relation to chemicals regulations.

    Science.gov (United States)

    Movalli, Paola; Dekker, René; Koschorreck, Jan; Treu, Gabriele

    2017-11-01

    Raptors are good sentinels of environmental contamination and there is good capability for raptor biomonitoring in Europe. Raptor biomonitoring can benefit from natural history museums (NHMs), environmental specimen banks (ESBs) and other collections (e.g. specialist raptor specimen collections). Europe's NHMs, ESBs and other collections hold large numbers of raptor specimens and samples, covering long periods of time. These collections are potentially a valuable resource for contaminant studies over time and space. There are strong needs to monitor contaminants in the environment to support EU and national chemical management. However, data on raptor specimens in NHMs, ESBs and other collections are dispersed, few are digitised, and they are thus not easy to access. Specimen coverage is patchy in terms of species, space and time. Contaminant research with raptors would be facilitated by creating a framework to link relevant collections, digitising all collections, developing a searchable meta-database covering all existing collections, making them more visible and accessible for contaminant research. This would also help identify gaps in coverage and stimulate specimen collection to fill gaps in support of prioritised contaminant monitoring. Collections can further support raptor biomonitoring by making samples available for analysis on request.

  1. Evidence for Legacy Contamination of Nitrate in Groundwater of North Carolina Using Monitoring and Private Well Data Models

    Science.gov (United States)

    Messier, K. P.; Kane, E.; Bolich, R.; Serre, M. L.

    2014-12-01

    Nitrate (NO3-) is a widespread contaminant of groundwater and surface water across the United States that has deleterious effects to human and ecological health. Legacy contamination, or past releases of NO3-, is thought to be impacting current groundwater and surface water of North Carolina. This study develops a model for predicting point-level groundwater NO3- at a state scale for monitoring wells and private wells of North Carolina. A land use regression (LUR) model selection procedure known as constrained forward nonlinear regression and hyperparameter optimization (CFN-RHO) is developed for determining nonlinear model explanatory variables when they are known to be correlated. Bayesian Maximum Entropy (BME) is then used to integrate the LUR model to create a LUR-BME model of spatial/temporal varying groundwater NO3- concentrations. LUR-BME results in a leave-one-out cross-validation r2 of 0.74 and 0.33 for monitoring and private wells, effectively predicting within spatial covariance ranges. The major finding regarding legacy sources NO3- in this study is that the LUR-BME models show the geographical extent of low-level contamination of deeper drinking-water aquifers is beyond that of the shallower monitoring well. Groundwater NO3- in monitoring wells is highly variable with many areas predicted above the current Environmental Protection Agency standard of 10 mg/L. Contrarily, the private well results depict widespread, low-level NO3-concentrations. This evidence supports that in addition to downward transport, there is also a significant outward transport of groundwater NO3- in the drinking water aquifer to areas outside the range of sources. Results indicate that the deeper aquifers are potentially acting as a reservoir that is not only deeper, but also covers a larger geographical area, than the reservoir formed by the shallow aquifers. Results are of interest to agencies that regulate surface water and drinking water sources impacted by the effects of

  2. An assessment of two decades of contaminant monitoring in the Nation’s Coastal Zone.

    OpenAIRE

    Kimbrough, K. L.; Lauenstein, G. G.; Christensen, J. D.; Apeti, D. A.

    2008-01-01

    Executive Summary: Information found in this report covers the years 1986 through 2005. Mussel Watch began monitoring a suite of trace metals and organic contaminants such as DDT, PCBs and PAHs. Through time additional chemicals were added, and today approximately 140 analytes are monitored. The Mussel Watch Program is the longest running estuarine and coastal pollutant monitoring effort conducted in the United States that is national in scope each year. Hundreds of scientific journal art...

  3. Contamination Effects Due to Space Environmental Interactions

    Science.gov (United States)

    Chen, Philip T.; Paquin, Krista C. (Technical Monitor)

    2001-01-01

    Molecular and particulate contaminants are commonly generated from the orbital spacecraft operations that are under the influence of the space environment. Once generated, these contaminants may attach to the surfaces of the spacecraft or may remain in the vicinity of the spacecraft. In the event these contaminants come to rest on the surfaces of the spacecraft or situated in the line-of-sight of the observation path, they will create various degrees of contamination effect which may cause undesirable effects for normal spacecraft operations, There will be circumstances in which the spacecraft may be subjected to special space environment due to operational conditions. Interactions between contaminants and special space environment may alter or greatly increase the contamination effect due to the synergistic effect. This paper will address the various types of contamination generation on orbit, the general effects of the contamination on spacecraft systems, and the typical impacts on the spacecraft operations due to the contamination effect. In addition, this paper will explain the contamination effect induced by the space environment and will discuss the intensified contamination effect resulting from the synergistic effect with the special space environment.

  4. Ecotoxicity monitoring and bioindicator screening of oil-contaminated soil during bioremediation.

    Science.gov (United States)

    Shen, Weihang; Zhu, Nengwu; Cui, Jiaying; Wang, Huajin; Dang, Zhi; Wu, Pingxiao; Luo, Yidan; Shi, Chaohong

    2016-02-01

    A series of toxicity bioassays was conducted to monitor the ecotoxicity of soils in the different phases of bioremediation. Artificially oil-contaminated soil was inoculated with a petroleum hydrocarbon-degrading bacterial consortium containing Burkholderia cepacia GS3C, Sphingomonas GY2B and Pandoraea pnomenusa GP3B strains adapted to crude oil. Soil ecotoxicity in different phases of bioremediation was examined by monitoring total petroleum hydrocarbons, soil enzyme activities, phytotoxicity (inhibition of seed germination and plant growth), malonaldehyde content, superoxide dismutase activity and bacterial luminescence. Although the total petroleum hydrocarbon (TPH) concentration in soil was reduced by 64.4%, forty days after bioremediation, the phytotoxicity and Photobacterium phosphoreum ecotoxicity test results indicated an initial increase in ecotoxicity, suggesting the formation of intermediate metabolites characterized by high toxicity and low bioavailability during bioremediation. The ecotoxicity values are a more valid indicator for evaluating the effectiveness of bioremediation techniques compared with only using the total petroleum hydrocarbon concentrations. Among all of the potential indicators that could be used to evaluate the effectiveness of bioremediation techniques, soil enzyme activities, phytotoxicity (inhibition of plant height, shoot weight and root fresh weight), malonaldehyde content, superoxide dismutase activity and luminescence of P. phosphoreum were the most sensitive. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Workshop 3.5: Closing the gap between exposure and effects in monitoring studies

    Science.gov (United States)

    Tillitt, Donald E.; Papoulias, Diana M.

    2003-01-01

    A major challenge to contaminant monitoring programs is the selection of an appropriate suite of measurements for assessing exposure and effects. Early monitoring programs relied solely on residue analysis to detect the organochlorine compounds that were in use at that time. A shift to the use of more transient, less persistent chemicals required that a new set of tools be developed to determine if an organism had been exposed. This led to the development of cellular and biochemical assays that could indicate the presence of these types of chemicals in biota and the environment. However, it was recognized that measures of contaminant presence alone were insufficient to assess the health of biota. As a result, considerable research began to be directed toward development of diagnostic tools for measuring chemical effects in fish and wildlife. Today, contaminant monitoring programs follow a paradigm for study design that emphasizes not only the use of measures of exposure, but also measures of effect. Using data from our monitoring and research studies for hormonally active substances, we discuss a variety of metrics of exposure and effects and their application to specific chemicals, and the current information gaps. We conclude that although several bioindicators of exposure and effect have been promoted and used, to date there continues to be a poor association between cause and effect for endocrine active substances. In part, this is due to the limited number of diagnostic tools that are available and to a lack of basic toxicological information concerning toxicokinetics and mechanisms of action of hormonally active chemicals in fish and wildlife species. In the foreseeable future, both tissue and environmental residue data, despite the many limitations, will continue to be an important component of monitoring programs for hormonally active chemicals as we continue to develop and validate more specific bioindicators of exposure and effects.

  6. Development of an expert system for the taking into account of uncertainties in the monitoring of internal contaminations

    International Nuclear Information System (INIS)

    Davesne, E.; Blanchardon, E.; Casanova, P.; Chojnacki, E.; Paquet, F.

    2010-01-01

    Internal contaminations may result from professional exposure and they can be monitored by anthropo-radiometric and radio-toxicological measurements which are interpreted in terms of embedded activity and effective dose by means of biokinetic and dosimetric models. In spite of standards, some uncertainties in the dosimetric interpretation of radio-toxicological measurements may remain. The authors report the development of a software (OPSCI code) which takes into account uncertainties related to the worker internal dosimetry, the calculation of the minimum detectable dose related to an exposure, and the development of a data monitoring programme

  7. Strategies for monitoring the emerging polar organic contaminants in water with emphasis on integrative passive sampling.

    Science.gov (United States)

    Söderström, Hanna; Lindberg, Richard H; Fick, Jerker

    2009-01-16

    Although polar organic contaminants (POCs) such as pharmaceuticals are considered as some of today's most emerging contaminants few of them are regulated or included in on-going monitoring programs. However, the growing concern among the public and researchers together with the new legislature within the European Union, the registration, evaluation and authorisation of chemicals (REACH) system will increase the future need of simple, low cost strategies for monitoring and risk assessment of POCs in aquatic environments. In this article, we overview the advantages and shortcomings of traditional and novel sampling techniques available for monitoring the emerging POCs in water. The benefits and drawbacks of using active and biological sampling were discussed and the principles of organic passive samplers (PS) presented. A detailed overview of type of polar organic PS available, and their classes of target compounds and field of applications were given, and the considerations involved in using them such as environmental effects and quality control were discussed. The usefulness of biological sampling of POCs in water was found to be limited. Polar organic PS was considered to be the only available, but nevertheless, an efficient alternative to active water sampling due to its simplicity, low cost, no need of power supply or maintenance, and the ability of collecting time-integrative samples with one sample collection. However, the polar organic PS need to be further developed before they can be used as standard in water quality monitoring programs.

  8. Monitoring for contaminants of emerging concern in drinking water using POCIS passive samplers.

    Science.gov (United States)

    Metcalfe, Chris; Hoque, M Ehsanul; Sultana, Tamanna; Murray, Craig; Helm, Paul; Kleywegt, Sonya

    2014-03-01

    Contaminants of emerging concern (CEC) have been detected in drinking water world-wide. The source of most of these compounds is generally attributed to contamination from municipal wastewater. Traditional water sampling methods (grab or composite) often require the concentration of large amounts of water in order to detect trace levels of these contaminants. The Polar Organic Compounds Integrative Sampler (POCIS) is a passive sampling technology that has been developed to concentrate trace levels of CEC to provide time-weighted average concentrations for individual compounds in water. However, few studies to date have evaluated whether POCIS is suitable for monitoring contaminants in drinking water. In this study, the POCIS was evaluated as a monitoring tool for CEC in drinking water over a period of 2 and 4 weeks with comparisons to typical grab samples. Seven "indicator compounds" which included carbamazepine, trimethoprim, sulfamethoxazole, ibuprofen, gemfibrozil, estrone and sucralose, were monitored in five drinking water treatment plants (DWTPs) in Ontario. All indicator compounds were detected in raw water samples from the POCIS in comparison to six from grab samples. Similarly, four compounds were detected in grab samples of treated drinking water, whereas six were detected in the POCIS. Sucralose was the only compound that was detected consistently at all five plants. The POCIS technique provided integrative exposures of CECs in drinking water at lower detection limits, while episodic events were captured via traditional sampling methods. There was evidence that the accumulation of target compounds by POCIS is a dynamic process, with adsorption and desorption on the sorbent occurring in response to ambient levels of the target compounds in water. CECs in treated drinking water were present at low ng L(-1) concentrations, which are not considered to be a threat to human health.

  9. Detection of microbial contaminations in drinking water using ATP measurements – evaluating potential for online monitoring

    DEFF Research Database (Denmark)

    Vang, Óluva Karin; Corfitzen, Charlotte B.; Albrechtsen, Hans-Jørgen

    2011-01-01

    There is an increasing call for fast and reliable methods for continuous monitoring of microbial drinking water quality in order to protect public health. The potential for Adenosine triphosphate (ATP) measurements as a real-time analysis for continuous monitoring of microbial drinking water...... quality was investigated through simulation of two contamination scenarios, i.e. drinking water contaminated with waste water and surface water at various concentrations. With ATP measurements it was possible to detect waste water diluted 1000-10,000 times in drinking water depending on sensitivity...... of reagent kit. Surface water diluted 100-1000 times was detected in drinking water with ATP measurements. ATP has the potential as an early warning tool, especially in the period when the contamination concentration is high. 2011 © American Water Works Association AWWA WQTC Conference Proceedings All Rights...

  10. Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2013 and FY2014 (revised)

    Energy Technology Data Exchange (ETDEWEB)

    Mizell, Steve A. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Miller, Julianne J. [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, Greg D. [Desert Research Inst. (DRI), Reno, NV (United States); Campbell, Scott A. [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2017-06-01

    The Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Contamination Area (CA) as a result of storm runoff, which supports National Nuclear Security Administration (NNSA) efforts to complete regulatory closure of the Soils Corrective Action Unit (CAU) contamination areas. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the appropriate closure design and post-closure monitoring program.

  11. Economics of place-based monitoring under the safe drinking water act, part I: spatial and temporal patterns of contaminants, and design of screening strategies.

    Science.gov (United States)

    Brands, Edwin; Rajagopal, R

    2008-08-01

    The goals of environmental legislation and associated regulations are to protect public health, natural resources, and ecosystems. In this context, monitoring programs should provide timely and relevant information so that the regulatory community can implement legislation in a cost-effective and efficient manner. The Safe Drinking Water Act (SDWA) of 1974 attempts to ensure that public water systems (PWSs) supply safe water to its consumers. As is the case with many other federal environmental statutes, SDWA monitoring has been implemented in relatively uniform fashion across the USA. In this three part series, spatial and temporal patterns in water quality data are utilized to develop, compare, and evaluate the economic performance of alternative place-based monitoring approaches to current monitoring practice. Under the Safe Drinking Water Act (SDWA), a common list of over 90 contaminants is analyzed nationwide using EPA-authorized laboratory procedures. National and state-level summaries of SDWA data have shown that not all contaminants occur in all places at all times. This hypothesis is confirmed and extended by showing that only a few (less than seven) contaminants are of concern in any one of 19 Iowa surface water systems studied. These systems collectively serve about 350,000 people and their sizes vary between 1,200 and 120,000. The distributions of contaminants found in these systems are positively skewed, with many non-detect measurements. A screening strategy to identify such contaminants in individual systems is presented. These findings have significant implications not only for the design of alternative monitoring programs, but also in multi-billion-dollar decisions that influence the course of future drinking water infrastructure, repair, and maintenance investments.

  12. Contaminant exposure and effects in pinnipeds: implications for Steller sea lion declines in Alaska.

    Science.gov (United States)

    Barron, Mace G; Heintz, Ron; Krahn, Margaret M

    2003-07-20

    After nearly 3 decades of decline, the western stock of Steller sea lions (SSL; Eumetopias jubatus) was listed as an endangered species in 1997. While the cause of the decline in the 1970s and 1980s has been attributed to nutritional stress, recent declines are unexplained and may result from other factors including the presence of environmental contaminants. SSL tissues show accumulation of butyltins, mercury, PCBs, DDTs, chlordanes and hexachlorobenzene. SSL habitats and prey are contaminated with additional chemicals including mirex, endrin, dieldrin, hexachlorocyclohexanes, tetrachlorodibenzo-p-dioxin (TCDD) and related compounds, cadmium and lead. In addition, many SSL haulouts and rookeries are located near other hazards including radioactivity, solvents, ordnance and chemical weapon dumps. PCB and DDT concentrations measured in a few SSL during the 1980s were the highest recorded for any Alaskan pinniped. Some contaminant exposures in SSL appear to be elevated in the Gulf of Alaska and Bering Sea compared to southeast Alaska, but there are insufficient data to evaluate geospatial relationships with any certainty. Based on very limited blubber data, current levels of PCBs may not pose a risk to SSL based on comparison to immunotoxicity tissue benchmarks, but SSL may have been at risk from pre-1990 PCB exposures. While exposure to PCBs and DDTs may be declining, SSL are likely exposed to a multitude of other contaminants that have not been monitored. The impacts of these exposures on SSL remain unknown because causal effects have not been established. Field studies with SSL have been limited in scope and have not yet linked contaminant exposures to adverse animal health or population effects. Several biomarkers may prove useful for monitoring exposure and additional research is needed to evaluate their utility in SSL. We conclude that there are insufficient data to reject the hypothesis that contaminants play a role in the continued decline of SSL, and suggest

  13. Zero-tension lysimeters: An improved design to monitor colloid-facilitated contaminant transport in the vadose zone

    International Nuclear Information System (INIS)

    Thompson, M.L.; Scharf, R.L.; Shang, C.

    1995-01-01

    There is increasing evidence that mobile colloids facilitate the long-distance transport of contaminants. The mobility of fine particles and macromolecules has been linked to the movement of actinides, organic contaminants, and heavy metals through soil. Direct evidence for colloid mobility includes the presence of humic materials in deep aquifers as well as coatings of accumulated clay, organic matter, or sesquioxides on particle or aggregate surfaces in subsoil horizons of many soils. The potential for colloid-facilitated transport of contaminants from hazardous-waste sites requires adequate monitoring before, during, and after in-situ remediation treatments. Zero-tension lysimeters (ZTLs) are especially appropriate for sampling water as it moves through saturated soil, although some unsaturated flow events may be sampled as well. Because no ceramic barrier or fiberglass wick is involved to maintain tension on the water (as is the case with other lysimeters), particles suspended in the water as well as dissolved species may be sampled with ZTLs. In this report, a ZTL design is proposed that is more suitable for monitoring colloid-facilitated contaminant migration. The improved design consists of a cylinder made of polycarbonate or polytetrafluoroethylene (PTFE) that is placed below undisturbed soil material. In many soils, a hydraulically powered tube may be used to extract an undisturbed core of soil before placement of the lysimeter. In those cases, the design has significant advantages over conventional designs with respect to simplicity and speed of installation. Therefore, it will allow colloid-facilitated transport of contaminants to be monitored at more locations at a given site

  14. Geophysical Monitoring of Hydrocarbon-Contaminated Soils Remediated with a Bioelectrochemical System.

    Science.gov (United States)

    Mao, Deqiang; Lu, Lu; Revil, André; Zuo, Yi; Hinton, John; Ren, Zhiyong Jason

    2016-08-02

    Efficient noninvasive techniques are desired for monitoring the remediation process of contaminated soils. We applied the direct current resistivity technique to image conductivity changes in sandbox experiments where two sandy and clayey soils were initially contaminated with diesel hydrocarbon. The experiments were conducted over a 230 day period. The removal of hydrocarbon was enhanced by a bioelectrochemical system (BES) and the electrical potentials of the BES reactors were also monitored during the course of the experiment. We found that the variation in electrical conductivity shown in the tomograms correlate well with diesel removal from the sandy soil, but this is not the case with the clayey soil. The clayey soil is characterized by a larger specific surface area and therefore a larger surface conductivity. In sandy soil, the removal of the diesel and products from degradation leads to an increase in electrical conductivity during the first 69 days. This is expected since diesel is electrically insulating. For both soils, the activity of BES reactors is moderately imaged by the inverted conductivity tomogram of the reactor. An increase in current production by electrochemically active bacteria activity corresponds to an increase in conductivity of the reactor.

  15. Groundwater pumping effects on contaminant loading management in agricultural regions.

    Science.gov (United States)

    Park, Dong Kyu; Bae, Gwang-Ok; Kim, Seong-Kyun; Lee, Kang-Kun

    2014-06-15

    Groundwater pumping changes the behavior of subsurface water, including the location of the water table and characteristics of the flow system, and eventually affects the fate of contaminants, such as nitrate from agricultural fertilizers. The objectives of this study were to demonstrate the importance of considering the existing pumping conditions for contaminant loading management and to develop a management model to obtain a contaminant loading design more appropriate and practical for agricultural regions where groundwater pumping is common. Results from this study found that optimal designs for contaminant loading could be determined differently when the existing pumping conditions were considered. This study also showed that prediction of contamination and contaminant loading management without considering pumping activities might be unrealistic. Motivated by these results, a management model optimizing the permissible on-ground contaminant loading mass together with pumping rates was developed and applied to field investigation and monitoring data from Icheon, Korea. The analytical solution for 1-D unsaturated solute transport was integrated with the 3-D saturated solute transport model in order to approximate the fate of contaminants loaded periodically from on-ground sources. This model was further expanded to manage agricultural contaminant loading in regions where groundwater extraction tends to be concentrated in a specific period of time, such as during the rice-growing season, using a method that approximates contaminant leaching to a fluctuating water table. The results illustrated that the simultaneous management of groundwater quantity and quality was effective and appropriate to the agricultural contaminant loading management and the model developed in this study, which can consider time-variant pumping, could be used to accurately estimate and to reasonably manage contaminant loading in agricultural areas. Copyright © 2014 Elsevier Ltd. All

  16. The Nile monitor (Varanus niloticus; Squamata: Varanidae) as a sentinel species for lead and cadmium contamination in sub-Saharan wetlands

    Energy Technology Data Exchange (ETDEWEB)

    Ciliberti, Alexandre [Universite de Lyon, F-69000, Lyon, Vetagro-Sup, Campus Veterinaire de Lyon, 1 avenue Bourgelat, F-69280 Marcy-l' Etoile, UMR 1233 Mycotoxines et Toxicologie Comparee des Xenobiotiques (France); Berny, Philippe, E-mail: p.berny@vetagro-sup.fr [Universite de Lyon, F-69000, Lyon, Vetagro-Sup, Campus Veterinaire de Lyon, 1 avenue Bourgelat, F-69280 Marcy-l' Etoile, UMR 1233 Mycotoxines et Toxicologie Comparee des Xenobiotiques (France); Delignette-Muller, Marie-Laure [Universite de Lyon, F-69000, Lyon, Vetagro-Sup, Campus Veterinaire de Lyon, 1 avenue Bourgelat, F-69280 Marcy-l' Etoile (France); Universite de Lyon, F-69000, Lyon, Universite Lyon 1, CNRS, UMR5558, Laboratoire de Biometrie et Biologie Evolutive, F-69622, Villeurbanne (France); Buffrenil, Vivian de [Museum National d' Histoire Naturelle, CC 48, 57 rue Cuvier, F-75005 Paris, Departement Histoire de la Terre, UMR 7207 CR2P (France)

    2011-10-15

    Wetland pollution is a matter of concern in sub-Saharan Africa. Though regularly exploited, the Nile monitor (Varanus niloticus), a large amphibious lizard, is not threatened. This work aims at assessing the value of this varanid as a sentinel species in surveys of environmental contamination by metals. Lead and cadmium quantifications were performed by graphite furnace-atomic absorption spectrophotometry in bone, intestine, kidney, liver and muscle in 71 monitors from three unevenly polluted sites in Mali and Niger, plus a reference site. The effects of sex, size and fat reserves as well as factors related to the sampling strategy (tissue sampled, sampling site) were studied with a mixed linear model. Metal contamination is moderate at the four sites but clear differences nevertheless occur. Lead levels are generally maximal in bone, with a gender-independent median value 320 ng.g{sup -1}. Median cadmium concentrations never exceed 70.2 ng.g{sup -1} in females (kidney) and 57.5 ng.g{sup -1} in males (intestine). Such levels should have no detrimental effects on the monitors. Lead and cadmium levels in muscles are generally below 200 and 20 ng.g{sup -1}, respectively, and should provoke no health hazard to occasional consumers of monitor meat. Metal organotropisms are consistent with those observed in other studies about Squamates: for lead: bone > [kidney, intestine, liver] > muscle in males and [bone, kidney] > [intestine, liver] > muscle in females; for cadmium: [liver, intestine, kidney] > [bone, muscle] for both genders. Females are more contaminated, especially in their kidneys. In this tissue, median values in ng.g{sup -1} are 129.7 and 344.0 for lead and 43.0 and 70.2 for cadmium, for males and females, respectively. Nile monitors can reveal subtle differences in local pollution by metals; moreover, the spatial resolution of the pollution indication that they give seems to be very sharp. The practical relevance of this new tool is thus validated.

  17. The Nile monitor (Varanus niloticus; Squamata: Varanidae) as a sentinel species for lead and cadmium contamination in sub-Saharan wetlands

    International Nuclear Information System (INIS)

    Ciliberti, Alexandre; Berny, Philippe; Delignette-Muller, Marie-Laure; Buffrenil, Vivian de

    2011-01-01

    Wetland pollution is a matter of concern in sub-Saharan Africa. Though regularly exploited, the Nile monitor (Varanus niloticus), a large amphibious lizard, is not threatened. This work aims at assessing the value of this varanid as a sentinel species in surveys of environmental contamination by metals. Lead and cadmium quantifications were performed by graphite furnace-atomic absorption spectrophotometry in bone, intestine, kidney, liver and muscle in 71 monitors from three unevenly polluted sites in Mali and Niger, plus a reference site. The effects of sex, size and fat reserves as well as factors related to the sampling strategy (tissue sampled, sampling site) were studied with a mixed linear model. Metal contamination is moderate at the four sites but clear differences nevertheless occur. Lead levels are generally maximal in bone, with a gender-independent median value 320 ng.g -1 . Median cadmium concentrations never exceed 70.2 ng.g -1 in females (kidney) and 57.5 ng.g -1 in males (intestine). Such levels should have no detrimental effects on the monitors. Lead and cadmium levels in muscles are generally below 200 and 20 ng.g -1 , respectively, and should provoke no health hazard to occasional consumers of monitor meat. Metal organotropisms are consistent with those observed in other studies about Squamates: for lead: bone > [kidney, intestine, liver] > muscle in males and [bone, kidney] > [intestine, liver] > muscle in females; for cadmium: [liver, intestine, kidney] > [bone, muscle] for both genders. Females are more contaminated, especially in their kidneys. In this tissue, median values in ng.g -1 are 129.7 and 344.0 for lead and 43.0 and 70.2 for cadmium, for males and females, respectively. Nile monitors can reveal subtle differences in local pollution by metals; moreover, the spatial resolution of the pollution indication that they give seems to be very sharp. The practical relevance of this new tool is thus validated.

  18. Monitoring of Urban Soil Contamination under Various Technogenic Impact: Comparison of the Two Seaside Cities

    Science.gov (United States)

    Miroshnychenko, Mykola; Krivitska, Ivetta; Hladkikh, Yevgenia

    2017-04-01

    of soil contamination in industrial, residential areas and parks has increased by 8-18%. This is caused by the accumulation of zinc, manganese, lead and mineral salts, sometimes in excess of the permitted rate. The contamination of plants in Mariupol is higher than soil contamination due to deposition of heavy metals directly from the atmosphere. Phytotoxicity effect has been discovered on the most of monitoring sites. Conclusions. Due to extremely high heterogeneity and combination of pollution from multiple sources, the changes of urban soil quality can be objectively assessed using observations which are systematic in space and time. The quality of urban soils is improving over five-ten years after reducing the amount of industrial pollution, but heavy metals are continuing to dissipate from the industrial zone to the surrounding land. Soil quality is deteriorating significantly in case of a constant dominance of the steel industry over other activities.

  19. Environmental contaminants in food. Volume II-part a: working papers. I. Priority setting of toxic substances for guiding monitoring programs. II. Five case studies of environmental food contamination

    International Nuclear Information System (INIS)

    1980-01-01

    This volume contains working papers written for Office of Technology Assessment (OTA) to assist in preparation of the report Environmental Contaminants in Food. The contents include: (1) Priority setting of toxic substances for guiding monitoring programs; and (2) Five case studies of environmental food contamination

  20. Borehole Calibration Facilities to Support Gamma Logging for Hanford Subsurface Investigation and Contaminant Monitoring - 13516

    International Nuclear Information System (INIS)

    McCain, R.G.; Henwood, P.D.; Pope, A.D.; Pearson, A.W.

    2013-01-01

    Repeated gamma logging in cased holes represents a cost-effective means to monitor gamma-emitting contamination in the deep vadose zone over time. Careful calibration and standardization of gamma log results are required to track changes and to compare results over time from different detectors and logging systems. This paper provides a summary description of Hanford facilities currently available for calibration of logging equipment. Ideally, all logging organizations conducting borehole gamma measurements at the Hanford Site will take advantage of these facilities to produce standardized and comparable results. (authors)

  1. Borehole Calibration Facilities to Support Gamma Logging for Hanford Subsurface Investigation and Contaminant Monitoring - 13516

    Energy Technology Data Exchange (ETDEWEB)

    McCain, R.G.; Henwood, P.D.; Pope, A.D.; Pearson, A.W. [S M Stoller Corporation, 2439 Robertson Drive, Richland, WA 99354 (United States)

    2013-07-01

    Repeated gamma logging in cased holes represents a cost-effective means to monitor gamma-emitting contamination in the deep vadose zone over time. Careful calibration and standardization of gamma log results are required to track changes and to compare results over time from different detectors and logging systems. This paper provides a summary description of Hanford facilities currently available for calibration of logging equipment. Ideally, all logging organizations conducting borehole gamma measurements at the Hanford Site will take advantage of these facilities to produce standardized and comparable results. (authors)

  2. Certified reference materials for organic contaminants for use in monitoring of the aquatic environment

    NARCIS (Netherlands)

    Boer, de J.; McGovern, E.

    2001-01-01

    Over the last three decades organic contaminants have been of increasing importance in environmental monitoring. Dioxins, furans, polychlorinated biphenyls and organochlorine pesticides have determined the environmental research agenda. This has led to an increasing demand for certified reference

  3. Sensitivity of radiation monitoring systems in Manila Ports in detecting contamination in foodstuff shipments

    International Nuclear Information System (INIS)

    Romallosa, Kristine Marie D.; Caseria, Estrella S.; Piquero, Ronald E.; Agustin, Jan Aldrich A.

    2011-01-01

    During the Fukushima Nuclear Power Plant accident in Japan, one of the Philippines' measures to protect the public from radiological hazards of the accident is by monitoring agricultural and food imports for radioactive contamination. In this study, the sensitivity of the mobile Radiation Monitoring System (RM) in Manila Ports in detecting contamination in incoming foodstuff shipments was determined. Large volume synthetic 137 Cs reference sources were used to determine the minimum detectable concentration (MDC) of the RMS. The reference sources have radioactivity concentrations that are comparable to the PNRI guidance level of 1000 Bg/kg for 137 Cs that is destined for general consumption. Results of the MDC measurements show that the RMS units are sensitive enough to detect radioactivity levels that are within the guidance levels provided that a) the minimum package lot is approximately 200 kg, b) the package is positioned at the detector side, and c) the alarm setting of RMS is as calibrated. It was therefore established that the RMS can be used to initially screen incoming foodstuff shipments of possible contamination and thereby help minimize potential radiation exposures to the public. (author)

  4. Long Term Remote Monitoring of TCE Contaminated Groundwater at Savannah River Site

    International Nuclear Information System (INIS)

    Duran, C.; Gudavalli, R.; Lagos, L.; Tansel, B.; Varona, J.; Allen, M.

    2004-01-01

    The purpose of this study was to develop a mobile self powered remote monitoring system enhanced for field deployment at Savannah River Site (SRS). The system used a localized power source with solar recharging and has wireless data collection, analysis, transmission, and data management capabilities. The prototype was equipped with a Hydrolab's DataSonde 4a multi-sensor array package managed by a Supervisory Control and Data Acquisition (SCADA) system, with an adequate pumping capacity of water samples for sampling and analysis of Trichloroethylene (TCE) in contaminated groundwater wells at SRS. This paper focuses on a study and technology development efforts conducted at the Hemispheric Center for Environmental Technology (HCET) at Florida International University (FIU) to automate the sampling of contaminated wells with a multi-sensor array package developed using COTS (Commercial Off The shelf) parts. Bladder pumps will pump water from different wells to the sensors array, water quality TCE indicator parameters are measured (i.e. pH, redox, ORP, DO, NO3 -, Cl-). In order to increase user access and data management, the system was designed to be accessible over the Internet. Remote users can take sample readings and collect data remotely over a web. Results obtained at Florida International University in-house testing and at a field deployment at the Savannah River Site indicate that this long term monitoring technique can be a feasible solution for the sampling of TCE indicator parameters at remote contaminated sites

  5. The Advanced Monitoring Systems Initiative--Performance Monitoring for DOE Environmental Remediation and Contaminant Containment

    Science.gov (United States)

    Haas, W. J.; Venedam, R. J.; Lohrstorfer, C. F.; Weeks, S. J.

    2005-05-01

    The Advanced Monitoring System Initiative (AMSI) is a new approach to accelerate the development and application of advanced sensors and monitoring systems in support of Department of Energy needs in monitoring the performance of environmental remediation and contaminant containment activities. The Nevada Site Office of the National Nuclear Security Administration (NNSA) and Bechtel Nevada manage AMSI, with funding provided by the DOE Office of Environmental Management (DOE EM). AMSI has easy access to unique facilities and capabilities available at the Nevada Test Site (NTS), including the Hazardous Materials (HazMat) Spill Center, a one-of-a-kind facility built and permitted for releases of hazardous materials for training purposes, field-test detection, plume dispersion experimentation, and equipment and materials testing under controlled conditions. AMSI also has easy access to the facilities and considerable capabilities of the DOE and NNSA National Laboratories, the Special Technologies Laboratory, Remote Sensing Laboratory, Desert Research Institute, and Nevada Universities. AMSI provides rapid prototyping, systems integration, and field-testing, including assistance during initial site deployment. The emphasis is on application. Important features of the AMSI approach are: (1) customer investment, involvement and commitment to use - including definition of needs, desired mode of operation, and performance requirements; and (2) employment of a complete systems engineering approach, which allows the developer to focus maximum attention on the essential new sensing element or elements while AMSI assumes principal responsibility for infrastructure support elements such as power, packaging, and general data acquisition, control, communication, visualization and analysis software for support of decisions. This presentation describes: (1) the needs for sensors and performance monitoring for environmental systems as seen by the DOE Long Term Stewardship Science and

  6. Contamination of estuaries from failing septic tank systems: difficulties in scaling up from monitored individual systems to cumulative impact.

    Science.gov (United States)

    Geary, Phillip; Lucas, Steven

    2018-02-03

    Aquaculture in many coastal estuaries is threatened by diffuse sources of runoff from different land use activities. The poor performance of septic tank systems (STS), as well as runoff from agriculture, may contribute to the movement of contaminants through ground and surface waters to estuaries resulting in oyster contamination, and following their consumption, impacts to human health. In monitoring individual STS in sensitive locations, it is possible to show that nutrients and faecal contaminants are transported through the subsurface in sandy soils off-site with little attenuation. At the catchment scale however, there are always difficulties in discerning direct linkages between failing STS and water contamination due to processes such as effluent dilution, adsorption, precipitation and vegetative uptake. There is often substantial complexity in detecting and tracing effluent pathways from diffuse sources to water bodies in field studies. While source tracking as well as monitoring using tracers may assist in identifying potential pathways from STS to surface waters and estuaries, there are difficulties in scaling up from monitored individual systems to identify their contribution to the cumulative impact which may be apparent at the catchment scale. The processes which may be obvious through monitoring and dominate at the individual scale may be masked and not readily discernible at the catchment scale due to impacts from other land use activities.

  7. Feasibility of using fiber optics for monitoring ground water contaminants

    International Nuclear Information System (INIS)

    Hirschfeld, T.; Deaton, T.; Milanovich, F.; Klainer, S.M.

    1984-06-01

    The report contains the results of the initial feasibility study for a research program undertaken to develop the technology needed to use fiber optics for monitoring groundwater contaminants. The technology appears especially well suited to the requirements of detection monitoring where a few indicator parameters can be measured continuously by sensors placed down small-diameter monitoring wells. Data are generated at a remote, centrally located fluorimeter, connected to the sampling sites by inexpensive optical fibers. The analytical method is laser-induced fluorescence which gives the desired sensitivity. The optrode, a chemical system and/or a mechanical device at the distal end of a fiber optic, furnishes the needed specificity. Various fiber and optrode configurations have been evaluated and their applications to groundwater monitoring are discussed. Feasibility is shown for physical measurements such as temperature, pressure and pH. Chemical detection and quantification of the actinides, inorganic and organic chlorides, sulfates, alcohols, aldehydes, pesticides and tracer materials are presented. Finally, it is shown that the need for smaller diameter wells (as compared to conventional sampling methods), and the ability to make up to 50 unattended in situ measurements, using a reasonably priced centralized fluorometer system connected to the sampling sites by inexpensive optical fibers, results in acceptable economy

  8. Mental contamination: The effects of religiosity.

    Science.gov (United States)

    Bilekli, Ilgun; Inozu, Mujgan

    2018-03-01

    Mental contamination, which occurs in the absence of contact with a contaminant, has a moral element. Previous studies evoked feelings of mental contamination via listening to a scenario, which described a non-consensual kiss. Since mental contamination has a moral element, we tested the effects of the level of religiosity on feelings of mental contamination and related variables in an experimental design. Female undergraduates of high religiosity (n = 48) and low religiosity (n = 44) were randomly assigned to listen to one of two audio recordings involving a consensual or non-consensual kiss from a man described as moral. Mental contamination feelings were evoked successfully in both groups. Effects of scenario condition and religiosity level were seen in mental contamination and related negative feelings. Participants who imagined a non-consensual kiss reported greatest feelings of mental contamination, and internal and external negative feelings. More importantly, high religiosity resulted in greater feelings of mental contamination, internal negative feelings, as well as urges to wash and actual washing behaviors. The current study was conducted on non-clinical Muslim females. This limits the generalization of the findings to the wider population. Mental contamination and related feelings can be seen in different forms at different levels of religiosity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Bulk laundry monitoring system

    International Nuclear Information System (INIS)

    Thakur, Vaishali M.; Jain, Amit; Verma, Amit; Anilkumar, S.; Babu, D.A.R.; Sharma, D.N.; Rande, N.R.; Singh, B.N.

    2012-01-01

    Protective wear (like boiler suits, hand gloves etc.) is essential while handling radioactive material in plants/laboratories. During the course of work, it is quite possible that protective wear may get contaminated. These protective wears are packed in laundry bags and send to Decontamination Centre (DC). There is a need for monitoring the laundry bags at the time of receipt, as well as before dispatch to respective locations to comply with AERB guidelines, To avoid cross contamination during wash cycle, contaminated bags (> 0.5 mR/h on surface) need to be segregated. Present paper describes the development of such system for monitoring surface dose rate on bags at the time of receipt. The system installed at ETP after calibration, effectively segregates the contaminated bags from the rest and prevents from cross contamination during wash cycle. Reduction in man-rem consumption due to semi automatic monitoring. Improved sensitivity due to good geometry, long counting time, background and attenuation corrections. Optimum utilization of decontamination chemicals based on level of contamination and keeping track of its inventory. Generation of decontamination process data base for improvement

  10. Pollution monitoring of puget sound with honey bees.

    Science.gov (United States)

    Bromenshenk, J J; Carlson, S R; Simpson, J C; Thomas, J M

    1985-02-08

    To show that honey bees are effective biological monitors of environmental contaminants over large geographic areas, beekeepers of Puget Sound, Washington, collected pollen and bees for chemical analysis. From these data, kriging maps of arsenic, cadmium, and fluoride were generated. Results, based on actual concentrations of contaminants in bee tissues, show that the greatest concentrations of contaminants occur close to Commencement Bay and that honey bees are effective as large-scale monitors.

  11. Comparison of active and passive sampling strategies for the monitoring of pesticide contamination in streams

    Science.gov (United States)

    Assoumani, Azziz; Margoum, Christelle; Guillemain, Céline; Coquery, Marina

    2014-05-01

    The monitoring of water bodies regarding organic contaminants, and the determination of reliable estimates of concentrations are challenging issues, in particular for the implementation of the Water Framework Directive. Several strategies can be applied to collect water samples for the determination of their contamination level. Grab sampling is fast, easy, and requires little logistical and analytical needs in case of low frequency sampling campaigns. However, this technique lacks of representativeness for streams with high variations of contaminant concentrations, such as pesticides in rivers located in small agricultural watersheds. Increasing the representativeness of this sampling strategy implies greater logistical needs and higher analytical costs. Average automated sampling is therefore a solution as it allows, in a single analysis, the determination of more accurate and more relevant estimates of concentrations. Two types of automatic samplings can be performed: time-related sampling allows the assessment of average concentrations, whereas flow-dependent sampling leads to average flux concentrations. However, the purchase and the maintenance of automatic samplers are quite expensive. Passive sampling has recently been developed as an alternative to grab or average automated sampling, to obtain at lower cost, more realistic estimates of the average concentrations of contaminants in streams. These devices allow the passive accumulation of contaminants from large volumes of water, resulting in ultratrace level detection and smoothed integrative sampling over periods ranging from days to weeks. They allow the determination of time-weighted average (TWA) concentrations of the dissolved fraction of target contaminants, but they need to be calibrated in controlled conditions prior to field applications. In other words, the kinetics of the uptake of the target contaminants into the sampler must be studied in order to determine the corresponding sampling rate

  12. Contamination monitoring of Na 131 I levels in therapy unit of Research Institute for Nuclear Medicine, Tehran University of Medical Sciences by indirect method (Wipe test)

    International Nuclear Information System (INIS)

    Beiki, D.; Shahhosseini, S.; Eftekhari, M.; Takavar, A.; Fard-Esfahani, A.

    2003-01-01

    Contamination with radiopharmaceuticals in nuclear medicine centres in addition to being a health concern requires time consuming decontamination efforts. According to Nuclear Regulatory Commission Contamination should be monitored in nuclear medicine centers where radiopharmaceuticals are prepared and administrated at the end of each working session; otherwise, contamination spread to other areas not only equipment but also personnel and other people will be expected. The wipe test for the presence of radioactivity is accomplished by wiping the surface over an area approximately 100 cm 2 with an absorbent paper, then counting it in an appropriate radiation detector. In this study, contamination monitoring of patient's rooms (4 rooms), entrance corridor, patient's corridor, waiting room, control room (nursing station), radiopharmaceutical storage room in therapy unit of Research Institute for Nuclear Medicine, Shariati hospital was performed by indirect method. Based on the results, some areas including storage room were contaminated. There was also a direct relationship between dose administrated and levels of contamination in patient's rooms. Regarding high uptake of iodine by thyroid gland and damaging effects of Na 131 I, weekly wipe tests are required to determine the level of contamination. Patient's rooms after discharging the patients and before re hospitalization specially should be checked. If these tests reveal contamination over standard levels, appropriate decontamination procedures should be carried out immediately

  13. Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2017

    Energy Technology Data Exchange (ETDEWEB)

    Mizell, Steve A. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Campbell, Scott A. [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, Greg [Desert Research Inst. (DRI), Las Vegas, NV (United States); Miller, Julianne J. [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2018-04-01

    The Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) as a result of storm runoff. This activity supports U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM-NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. Air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content are collected at the meteorological station. The maximum, minimum, and average or total values (as appropriate) for each of these parameters are recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrology station are also recorded for every 10-minute interval. This report presents data collected from these stations during fiscal year (FY) 2017. During the FY2017 reporting period, the warmest months were June, July, and August and the coldest were December and January. Solar radiation showed the same seasonal trend, although the months with the most solar radiation were May and June. Monthly mean wind speeds were highest in the spring (April and May). Winds were generally from the southwest during the summer and from the northwest throughout the remainder of the year. The monthly average

  14. Levels and trends of contaminants in humans of the Arctic.

    Science.gov (United States)

    Gibson, Jennifer; Adlard, Bryan; Olafsdottir, Kristin; Sandanger, Torkjel Manning; Odland, Jon Øyvind

    2016-01-01

    The Arctic Monitoring and Assessment Programme (AMAP) is one of the six working groups established under the Arctic Council. AMAP is tasked with monitoring the levels of contaminants present in the Arctic environment and people as well as assessing their effects on a continuous basis, and reporting these results regularly. Most of the presented data have been collected over the last 20 years and are from all eight Arctic countries. Levels of contaminants appear to be declining in some of the monitored Arctic populations, but it is not consistent across the Arctic. Most Arctic populations continue to experience elevated levels of these contaminants compared to other populations monitored globally. There are certain contaminants, such as perfluorinated compounds and polybrominated diphenyl ethers, which are still increasing in Arctic populations. These contaminants require more investigation to find out the predominant and important sources of exposure, and whether they are being transported to the Arctic through long-range transport in the environment.

  15. Monitoring priority substances, other organic contaminants and heavy metals in a volcanic aquifer from different sources and hydrological processes

    International Nuclear Information System (INIS)

    Estevez, Esmeralda; Cabrera, María del Carmen; Fernández-Vera, Juan Ramón; Molina-Díaz, Antonio; Robles-Molina, José; Palacios-Díaz, María del Pino

    2016-01-01

    Irrigation with reclaimed water (R) is necessary to guarantee the sustainability of semi-arid areas. Results obtained during a two years monitoring network (2009–2011) in Gran Canaria are presented, including the analysis of chemical parameters, N and S isotopes, priority substances (2008/105/EC, 2013/39/EU), other organic contaminants and heavy metals in groundwater and R used to irrigate a golf course. The aims of this work are to evaluate the contamination in a volcanic aquifer, relate the presence of organic contaminants and heavy metals with the hydrogeochemistry and identify pollution sources in the area. No priority substance exceeded the EU thresholds for surface water, although seventeen were detected in R. The most frequent compounds were hexachlorobenzene, chlorpyrifos ethyl, fluorene, phenanthrene and pyrene. These compounds were detected at low concentration, except chlorpyrifos. Chlorpyrifos ethyl, terbuthylazine, diuron, terbutryn, procymidone, atrazine and propazine exceeded the European threshold concentration for pesticides in groundwater (100 ng L"−"1). Therefore, the priority substances chlorpyrifos ethyl and diuron must be included in monitoring studies. The priority pesticides chlorfenvinphos and diazinon were always detected in R but rarely in groundwater. Besides, the existence of contaminants not related to the current R irrigation has been identified. Absence of environmental problems related to heavy metals can be expected. The relationship among contaminant presence, hydrogeochemistry, including the stable isotopic prints of δ"1"8O, δ"1"5N and δ"3"4S and preferential recharge paths has been described. The coastal well shows high values of EC, nitrate, a variable chemistry, and 50% of organic contaminants detected above 100 ng L"−"1. The well located in the recharge area presents a stable hydrochemistry, the lowest value of δ"1"5N and the lowest contaminants occurrence. The area is an example of a complex volcanic media with

  16. Monitoring priority substances, other organic contaminants and heavy metals in a volcanic aquifer from different sources and hydrological processes

    Energy Technology Data Exchange (ETDEWEB)

    Estevez, Esmeralda, E-mail: eestevez@proyinves.ulpgc.es [Dpt. Física (GEOVOL), Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Canary Islands (Spain); Agrifood and Phytopathological Laboratory (Cabildo de Gran Canaria), 35413 Arucas, Canary Islands (Spain); Cabrera, María del Carmen, E-mail: mcarmen.cabrera@ulpgc.es [Dpt. Física (GEOVOL), Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Canary Islands (Spain); IMDEA Water Institute, Alcalá de Henares, Madrid (Spain); Fernández-Vera, Juan Ramón, E-mail: jrfernandezv@grancanaria.com [Agrifood and Phytopathological Laboratory (Cabildo de Gran Canaria), 35413 Arucas, Canary Islands (Spain); Molina-Díaz, Antonio, E-mail: amolina@ujaen.es [Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaen, 23071 Jaen (Spain); Robles-Molina, José, E-mail: jroblesmol@gmail.com [Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaen, 23071 Jaen (Spain); Palacios-Díaz, María del Pino, E-mail: mp.palaciosdiaz@ulpgc.es [Dpt. de Patología Animal, Producción Animal, Bromatología y Tecnología de los Alimentos (GEOVOL), Universidad de Las Palmas de Gran Canaria, 35413 Arucas, Canary Islands (Spain)

    2016-05-01

    Irrigation with reclaimed water (R) is necessary to guarantee the sustainability of semi-arid areas. Results obtained during a two years monitoring network (2009–2011) in Gran Canaria are presented, including the analysis of chemical parameters, N and S isotopes, priority substances (2008/105/EC, 2013/39/EU), other organic contaminants and heavy metals in groundwater and R used to irrigate a golf course. The aims of this work are to evaluate the contamination in a volcanic aquifer, relate the presence of organic contaminants and heavy metals with the hydrogeochemistry and identify pollution sources in the area. No priority substance exceeded the EU thresholds for surface water, although seventeen were detected in R. The most frequent compounds were hexachlorobenzene, chlorpyrifos ethyl, fluorene, phenanthrene and pyrene. These compounds were detected at low concentration, except chlorpyrifos. Chlorpyrifos ethyl, terbuthylazine, diuron, terbutryn, procymidone, atrazine and propazine exceeded the European threshold concentration for pesticides in groundwater (100 ng L{sup −1}). Therefore, the priority substances chlorpyrifos ethyl and diuron must be included in monitoring studies. The priority pesticides chlorfenvinphos and diazinon were always detected in R but rarely in groundwater. Besides, the existence of contaminants not related to the current R irrigation has been identified. Absence of environmental problems related to heavy metals can be expected. The relationship among contaminant presence, hydrogeochemistry, including the stable isotopic prints of δ{sup 18}O, δ{sup 15}N and δ{sup 34}S and preferential recharge paths has been described. The coastal well shows high values of EC, nitrate, a variable chemistry, and 50% of organic contaminants detected above 100 ng L{sup −1}. The well located in the recharge area presents a stable hydrochemistry, the lowest value of δ{sup 15}N and the lowest contaminants occurrence. The area is an example of a complex

  17. Combining Modeling and Monitoring to Produce a New Paradigm of an Integrated Approach to Providing Long-Term Control of Contaminants

    Science.gov (United States)

    Fogwell, T. W.

    2009-12-01

    Sir David King, Chief Science Advisor to the British government and Cambridge University Professor, stated in October 2005, "The scientific community is considerably more capable than it has been in the past to assist governments to avoid and reduce risk to their own populations. Prime ministers and presidents ignore the advice from the science community at the peril of their own populations." Some of these greater capabilities can be found in better monitoring techniques applied to better modeling methods. These modeling methods can be combined with the information derived from monitoring data in order to decrease the risk of population exposure to dangerous substances and to promote efficient control or cleanup of the contaminants. An introduction is presented of the types of problems that exist for long-term control of radionuclides at DOE sites. A breakdown of the distributions at specific sites is given, together with the associated difficulties. A paradigm for remediation showing the integration of monitoring with modeling is presented. It is based on a feedback system that allows for the monitoring to act as principal sensors in a control system. The resulting system can be optimized to improve performance. Optimizing monitoring automatically entails linking the monitoring with modeling. If monitoring designs were required to be more efficient, thus requiring optimization, then the monitoring automatically becomes linked to modeling. Records of decision could be written to accommodate revisions in monitoring as better modeling evolves. Currently the establishment of a very prescriptive monitoring program fails to have a mechanism for improving models and improving control of the contaminants. The technical pieces of the required paradigm are already available; they just need to be implemented and applied to solve the long-term control of the contaminants. An integration of the various parts of the system is presented. Each part is described, and examples are

  18. Experiences in monitoring airborne radioactive contamination in JAERI

    International Nuclear Information System (INIS)

    Ikezawa, Y.; Okamoto, T.; Yabe, A.

    1980-01-01

    The following results were obtained at the Japan Atomic Energy Research Institute (JAERI) from experience in air monitoring at the hot cells for handling highly radioactive materials, the glove box containing plutonium and the cell for producing 99 Mo. (1) The ratios of activities of airborne dust to those of whole dust were of the order of 10 -2 for the semi-volatile form of 125 Sb, and 10 -3 to 10 -4 for the particulate form of 137 Cs, 144 Ce and 144 Pr, when irradiated fuels were cut in the hot cells. (2) The activity median aerodynamic diameter (AMAD) of airborne particle size distributions varied from O.4 to 15 μm with changing geometric standard deviation (sigmasub(g)) 1.7 to 7, depending on types of metallurgical treatment of fuels and on kinds of work in the cells. (3) A resuspension factor (the ratio of the concentration of airborne contamination to the surface contamination) was found to be 4x10 -8 to approximately 2x10 -7 cm -1 for plutonium oxide deposited on the floor surface. (4) The collection efficiency of the charcoal-loaded filter paper for airborne radioiodine, consisting of 60% inorganic and 40% organic iodide, was over 95% under conditions of relative humidity 40 to approximately 80% and face velocity 50 cm/sec, during the production of 99 Mo. (H.K.)

  19. Understanding transport pathways in a river system - Monitoring sediments contaminated by an incident

    Science.gov (United States)

    Dietrich, S.; Kleisinger, C.; Hillebrand, G.; Claus, E.; Schwartz, R.; Carls, I.; Winterscheid, A.; Schubert, B.

    2016-12-01

    Experiments to trace transport of sediments and suspended particulate matter on a river scale are an expensive and difficult venture, since it causes a lot of official requirements. In spring 2015, polychlorinated biphenyls (PCB) were released during restoration works at a bridge in the upper part of the Elbe River, near the Czech-German border. In this study, the particle-bound PCB-transport is applied as a tracer for monitoring transport pathways of suspended solids (SS) along a whole river stretch over 700 km length. The incident was monitored by concentration measurements of seven indicator PCB congeners along the inland part of the Elbe River as well as in the Elbe estuary. Data from 15 monitoring stations (settling tanks) as well as from two longitudinal campaigns (grab samples) along the river in July and August 2015 are considered. The total PCB load is calculated for all stations on the basis of monthly contaminant concentrations and daily suspended sediment concentrations. Monte-Carlo simulations assess the uncertainties of the calculated load. 1D water levels and GIS analysis were used to locate temporal storage areas for the SS. It is shown that the ratio of high versus low chlorinated PCB congeners is a suitable tracer to distinguish the PCB load of the incident from the long-term background signal. Furthermore, the reduction of total PCB load within the upper Elbe indicates that roughly 24% of the SS were transported with the water by wash load. Approximately 600 km downstream of the incident site, the PCB-marked wash load was first identified in July 2015. PCB load transported intermittently in suspension was detected roughly 400 km downstream of the incident site by August 2015. In the Elbe Estuary, PCB-marked SS were only found upstream of the steep slope of water depth (approx. 4 to 15 m) within Hamburg harbor that acts as a major sediment sink. Here, SS from the inland Elbe are mixed with lowly contaminated marine material, which may mask the

  20. A General LC-MS/MS Method for Monitoring Potential β-Lactam Contamination in Drugs and Drug-Manufacturing Surfaces.

    Science.gov (United States)

    Qiu, Chen; Zhu, Hongbin; Ruzicka, Connie; Keire, David; Ye, Hongping

    2018-05-15

    Penicillins and some non-penicillin β-lactams may cause potentially life-threatening allergic reactions. Thus, possible cross contamination of β-lactams in food or drugs can put people at risk. Therefore, when there is a reasonable possibility that a non-penicillin product could be contaminated by penicillin, the drug products are tested for penicillin contamination. Here, a sensitive and rapid method for simultaneous determination of multiple β-lactam antibiotics using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated. Mass spectral acquisition was performed on a Q-Exactive HF mass spectrometer in positive ion mode with parallel reaction monitoring (PRM). The method was validated for seven β-lactam antibiotics including one or two from each class and a synthetic intermediate. The quantification precision and accuracy at 200 ppb were in the range of ± 1.84 to ± 4.56 and - 5.20 to 3.44%, respectively. The limit of detection (LOD) was 0.2 ppb, and the limit of quantitation (LOQ) was 2 ppb with a linear dynamic range (LDR) of 2-2000 ppb for all eight β-lactams. From various drug products, the recoveries of eight β-lactams at 200 and 2 ppb ranged from 93.8 ± 3.2 to 112.1 ± 4.2% and 89.7 ± 4.6 to 110.6 ± 1.9%, respectively. The application of the method for detecting cross contamination of trace β-lactams (0.2 ppb) and for monitoring facility surface cleaning was also investigated. This sensitive and fast method was fit-for-purpose for detecting and quantifying trace amount of β-lactam contamination, monitoring cross contamination in manufacturing processes, and determining potency for regulatory purposes and for quality control.

  1. Monitoring organic contaminants in eggs of glaucous and glaucous-winged gulls (Larus hyperboreus and Larus glaucescens) from Alaska

    International Nuclear Information System (INIS)

    Vander Pol, Stacy S.; Becker, Paul R.; Ellisor, Michael B.; Moors, Amanda J.; Pugh, Rebecca S.; Roseneau, David G.

    2009-01-01

    Gull eggs have been used to monitor contaminants in many parts of the world. The Seabird Tissue Archival and Monitoring Project (STAMP) is a long-term program designed to track trends in pollutants in northern marine environments using seabird eggs. Glaucous and glaucous-winged gull (Larus hyperboreus and Larus glaucescens) eggs collected in 2005 from seven Alaskan colonies were analyzed for organic contaminants. Concentrations ranged from below detection limits to 322 ng g -1 wet mass in one egg for 4,4'-DDE and differed among the samples collected in the Gulf of Alaska and Bering and Chukchi Seas. Chick growth and survival rates may be affected by the contaminant levels found in the eggs, but the eggs should be safe for human consumption if they are eaten in small quantities. STAMP plans to continue collecting and banking gull eggs for future real-time and retrospective analyses. - Organic contaminant concentrations in Alaskan gull eggs could possibly be affecting chick growth and survival rates, but the eggs should be safe for humans to eat in small quantities

  2. Exercise of laboratory comparison for contamination monitor calibration between LNMRI/IRD and LCR/UERJ - 2016

    International Nuclear Information System (INIS)

    Cabral, T.S.; David, M.

    2016-01-01

    This work was motivated by the need to decide on the best methodology to be applied in the next contamination monitor calibration comparisons with the Brazilian network of calibration radiation monitors. The calibration factor was chosen as a response calibration performed in the four monitors used in this comparison because it does not require the detector area or probe thereby reducing an important variable. It was observed that the variation of the positioning system may have an influence up to 10% in calibration. The results obtained for the calibration factor showed a difference of up to 31.2%. (author)

  3. Air Monitoring Leads to Discovery of New Contamination at Radioactive Waste Disposal Site (Area G) at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Kraig, D.H.; Conrad, R.C.

    1999-01-01

    Air monitoring at Area G, the low-level radioactive waste disposal area at Los Alamos National Laboratory, revealed increased air concentrations of 239 Pu and 241 Am at one location along the north boundary. This air monitoring location is a couple of meters north of a dirt road used to access the easternmost part of Area G. Air concentrations of 238 Pu were essentially unaffected, which was puzzling because the 238 Pu and 239 Pu are present in the local, slightly contaminated soils. Air concentrations of these radionuclides increased about a factor of ten in early 1995 and remained at those levels until the first quarter of 1996. During the spring of 1996 air concentrations again increased by a factor of about ten. No other radionuclides were elevated and no other Area G stations showed elevations of these radionuclides. After several formal meetings didn't provide an adequate cause for the elevations, a gamma survey was performed and showed a small area of significant contamination just south of the monitor location. We found in February, 1995, a trench for a water line had been dug within a meter of so of the air stations. Then, during early 1996, the dirt road was rerouted such that its new path was directly over the unknown contamination. It appears that the trenching brought contaminated material to the surface and caused the first rise in air concentrations and then the rerouting of the road over the contamination caused the second rise, during 1996. We also found that during 1976 and 1977 contaminated soils from the clean-up of an old processing facility had been spread over the filled pits in the vicinity of the air monitors. These soils were very low in 238Pu which explains why we saw very little 238 Pu in the increased air concentrations. A layer of gravel and sand was spread over the contaminated area. Although air concentrations of 239 Pu and 241 Am dropped considerably, the y have not returned to pre-1995 levels

  4. PCDDF and pesticides monitoring in a dioxin contaminated area in Rio de Janeiro - Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Carvalhaes, G.; Azevedo, J.A.; Azevedo, G.; Machado, M.; Brooks, P. [Analytical Solutions, Rio de Janeiro (Brazil)

    2004-09-15

    During the 40's and 50's there had been a hexachlorocyclohexane(HCH) industry in Duque de Caxias, state of Rio de Janeiro, Brazil. Duque de Caxias is a very important borough within the state's political and administrative structure. It is located in a strategic point connecting Minas Gerais and Rio de Janeiro. It also holds one of Brazil's greatest petroleum refineries. For 20 years, this factory (which is located next to an orphanage called Cidade dos Meninos, an area belonging to the Ministry of Social Assistance) produced thousands of tons of HCH and also other pesticides, such as DDT, DDD and DDE. In the beginning of the 60's, the industry had its activities stopped1. In 1989, significant amounts of HCH had been found by local inspectors in Duque de Caxias, where it had been being sold for use in agriculture. Once the product's usage had already been prohibited in Brazil, after a investigation authorities found that it would come from the inactive industry. Both environmental and public health institutions decided to use a mixture of lime and soil, in order to destroy the residues and organic compounds found in the old plant. Such procedure would cause a greater problem, for the lime used wouldn't meet the right proportions of the large area and its contaminated soil. In addition, it also affected the water supply and the local population. The consequences have been disastrous. Data referring to breastfeeding and blood revealed alarming pesticide rates that endangered the local people health conditions both in short and long term. After 14 years, monitoring is still necessary in that region so it is possible to control contamination and its damage related to secondary reactions, climatic effects and soil structure. For this reason, a monitoring program has been developed in order to investigate the rates of certain pesticides and PCDD/F in locations near the contamination field.

  5. Remediating and Monitoring White Phosphorus Contamination at Eagle River Flats (Operable Unit C), Fort Richardson, Alaska

    National Research Council Canada - National Science Library

    Walsh, M. E; Racine, C. H; Collins, C. M; Walsh, M. R; Bailey, R. N

    2001-01-01

    .... Army Engineer District, Alaska, and U.S. Army Alaska, Public Works, describing the results of research, monitoring, and remediation efforts addressing the white phosphorus contamination in Eagle River Flats, an 865-ha estuarine salt marsh...

  6. Evaluation of Using Caged Clams to Monitor Contaminated Groundwater Exposure in the Near-Shore Environment of the Hanford Site 300 Area

    Energy Technology Data Exchange (ETDEWEB)

    Larson, Kyle B.; Poston, Ted M.; Tiller, Brett L.

    2008-01-31

    The Asiatic clam (Corbicula fluminea) has been identified as an indicator species for locating and monitoring contaminated groundwater in the Columbia River. Pacific Northwest National Laboratory conducted a field study to explore the use of caged Asiatic clams to monitor contaminated groundwater upwelling in the 300 Area near-shore environment and assess seasonal differences in uranium uptake in relation to seasonal flow regimes of the Columbia River. Additional objectives included examining the potential effects of uranium accumulation on growth, survival, and tissue condition of the clams. This report documents the field conditions and procedures, laboratory procedures, and statistical analyses used in collecting samples and processing the data. Detailed results are presented and illustrated, followed by a discussion comparing uranium concentrations in Asiatic clams collected at the 300 Area and describing the relationship between river discharge, groundwater indicators, and uranium in clams. Growth and survival, histology, and other sources of environmental variation also are discussed.

  7. Exposure assessment of process-related contaminants in food by biomarker monitoring.

    Science.gov (United States)

    Rietjens, Ivonne M C M; Dussort, P; Günther, Helmut; Hanlon, Paul; Honda, Hiroshi; Mally, Angela; O'Hagan, Sue; Scholz, Gabriele; Seidel, Albrecht; Swenberg, James; Teeguarden, Justin; Eisenbrand, Gerhard

    2018-01-01

    Exposure assessment is a fundamental part of the risk assessment paradigm, but can often present a number of challenges and uncertainties. This is especially the case for process contaminants formed during the processing, e.g. heating of food, since they are in part highly reactive and/or volatile, thus making exposure assessment by analysing contents in food unreliable. New approaches are therefore required to accurately assess consumer exposure and thus better inform the risk assessment. Such novel approaches may include the use of biomarkers, physiologically based kinetic (PBK) modelling-facilitated reverse dosimetry, and/or duplicate diet studies. This review focuses on the state of the art with respect to the use of biomarkers of exposure for the process contaminants acrylamide, 3-MCPD esters, glycidyl esters, furan and acrolein. From the overview presented, it becomes clear that the field of assessing human exposure to process-related contaminants in food by biomarker monitoring is promising and strongly developing. The current state of the art as well as the existing data gaps and challenges for the future were defined. They include (1) using PBK modelling and duplicate diet studies to establish, preferably in humans, correlations between external exposure and biomarkers; (2) elucidation of the possible endogenous formation of the process-related contaminants and the resulting biomarker levels; (3) the influence of inter-individual variations and how to include that in the biomarker-based exposure predictions; (4) the correction for confounding factors; (5) the value of the different biomarkers in relation to exposure scenario's and risk assessment, and (6) the possibilities of novel methodologies. In spite of these challenges it can be concluded that biomarker-based exposure assessment provides a unique opportunity to more accurately assess consumer exposure to process-related contaminants in food and thus to better inform risk assessment.

  8. Emergency preparedness and internal contamination monitoring

    International Nuclear Information System (INIS)

    Rahola, T.; Suomela, M.

    2000-01-01

    After the radiation accidents in Chernobyl, Ukraina in 1986 and in Goiania, Brasil in 1987, much resource have been spent on improving emergency preparedness. Especially regarding transfer of information using the most recent techniques and establishment of 24 hour emergency service of radiation safety experts the development has been fast. The very first measures in a possible emergency situation have been trained nationally and internationally. Less attention has been paid to measures in a somewhat later phase. To be able to react fast enough in an emergency situation it is essential to have well documented plans, written instructions and suitable measurement equipment ready for use. Equally important is that there is trained staff prepared to do measurements without delay. In the first phase of a nuclear accident radioactive iodine is of primary concern regarding internal contamination. After the Chernobyl accident the number of childhood thyroidea cancer clearly exceeded the expected number. Reliable direct measurements of I-131 in the thyroidea in Ukraina, Russia and Belarussia were done only to a limited number of children. Many uncertainties are involved in the data used for dose estimation. Later the body burdens of radiocesium or other radionuclides might be of most importance. Normal whole-body counting instruments can be used if only small groups need to be measured. For large groups of people in an emergency situation faster methods are needed. Different types of monitors installed at places where radiation workers are controlled for internal contamination as well as gamma cameras at hospitals can be used. Rapid field measurements of the whole-body and especially of the thyroid can been done with less sophisticated instruments. In the acute phase of a nuclear accident such measurements should be done without delay. Instruments and staff trained to use them should be available and plans for which groups of people to measure prepared. The detection level

  9. Design, construction and monitoring of temporary storage facilities for removed contaminants

    International Nuclear Information System (INIS)

    Saegusa, Hiromitsu; Funaki, Hironori; Kurikami, Hiroshi; Sakamoto, Yoshiaki; Tokizawa, Takayuki

    2013-01-01

    Since the Fukushima Daiichi nuclear power plant accident caused by the Tohoku Region Pacific Coast Earthquake on March 11, 2011, decontamination work has been conducted in the surrounding environment within the Fukushima prefecture. Removed contaminants including soil, grass and trees are to be stored safely at temporary storage facilities for up to three years, after which they will be transferred to a planned interim storage facility. The decontamination pilot project was carried out in both the restricted and planned evacuation areas in order to assess decontamination methods and demonstrate measures for radiation protection of workers. Fourteen temporary storage facilities of different technical specifications were designed and constructed under various topographic conditions and land use. In order to support the design, construction and monitoring of temporary storage facilities for removed contaminants during the full-scale decontamination within the prefecture of Fukushima, technical know-how obtained during the decontamination pilot project has been identified and summarized in this paper. (author)

  10. Evaluating legacy contaminants and emerging chemicals in marine environments using adverse outcome pathways and biological effects-directed analysis.

    Science.gov (United States)

    Hutchinson, Thomas H; Lyons, Brett P; Thain, John E; Law, Robin J

    2013-09-30

    Natural and synthetic chemicals are essential to our daily lives, food supplies, health care, industries and safe sanitation. At the same time protecting marine ecosystems and seafood resources from the adverse effects of chemical contaminants remains an important issue. Since the 1970s, monitoring of persistent, bioaccumulative and toxic (PBT) chemicals using analytical chemistry has provided important spatial and temporal trend data in three important contexts; relating to human health protection from seafood contamination, addressing threats to marine top predators and finally providing essential evidence to better protect the biodiversity of commercial and non-commercial marine species. A number of regional conventions have led to controls on certain PBT chemicals over several years (termed 'legacy contaminants'; e.g. cadmium, lindane, polycyclic aromatic hydrocarbons [PAHs] and polychlorinated biphenyls [PCBs]). Analytical chemistry plays a key role in evaluating to what extent such regulatory steps have been effective in leading to reduced emissions of these legacy contaminants into marine environments. In parallel, the application of biomarkers (e.g. DNA adducts, CYP1A-EROD, vitellogenin) and bioassays integrated with analytical chemistry has strengthened the evidence base to support an ecosystem approach to manage marine pollution problems. In recent years, however,the increased sensitivity of analytical chemistry, toxicity alerts and wider environmental awareness has led to a focus on emerging chemical contaminants (defined as chemicals that have been detected in the environment, but which are currently not included in regulatory monitoring programmes and whose fate and biological impacts are poorly understood). It is also known that natural chemicals (e.g. algal biotoxins) may also pose a threat to marine species and seafood quality. Hence complex mixtures of legacy contaminants, emerging chemicals and natural biotoxins in marine ecosystems represent

  11. Environmental geophysics and geochemistry for contamination mapping and monitoring 1

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tai Sup; Lee, Sang Kyu; Hong, Young Kook [Korea Inst. of Geology Mining and Materials, Taejon (Korea, Republic of); and others

    1995-12-01

    This study aims to provide the technologies which can be practically used for contamination mapping and monitoring. To accomplish this goal, the geophysical and geochemical expertise and techniques commonly used in the mineral resources exploration are employed. In the first year of the three-year-long project, the purpose of the study is to introduce the optimum methodologies among the geophysical and geochemical techniques to tackle the various cases of environmental contamination. To achieve the purpose, case studies of the developed countries were surveyed and analyzed through the various kinds of literatures. The followings are categorized to be solved by geophysical methods: 1) delineation of water system pollution by acid mine drainage and distributions of waste rocks in the closed mine area, 2) defining boundaries of subsurface contamination due to oil seepage, 3) zoning of sea water intrusion in the seashore or subsurface geology highly containing salt, 4) locating of buried metallic wastes such as pipes and drums which can cause the secondary pollution by corrosion, and 5) outlining of the subsurface area polluted by leachate from the landfill. To experiment the above items, various geophysical methods were applied to the corresponding test sites. From these experiments, the applicabilities of the respective geophysical method were analyzed, and the optimum methods were derived for the various pollution types. Furthermore, electric and electromagnetic surveys data processing software were developed to quantitatively interpret and highly resolve the geology. The environmental assignments which can be solved by geochemical methods include: 1) drainage pollution by coal mine effluents, 2)subsurface contamination of oil-spill, 3) sea water intrusion, 4) dispersion of toxic heavy metallic elements in the metal mines, and 5) radon environmental geochemistry. The appropriate test sites for applying the geochemical methods were selected. (Abstract Truncated)

  12. Long-term ERT monitoring of biogeochemical changes of an aged hydrocarbon contamination

    Science.gov (United States)

    Caterina, David; Flores Orozco, Adrian; Nguyen, Frédéric

    2017-06-01

    Adequate management of contaminated sites requires information with improved spatio-temporal resolution, in particular to assess bio-geochemical processes, such as the transformation and degradation of contaminants, precipitation of minerals or changes in groundwater geochemistry occurring during and after remediation procedures. Electrical Resistivity Tomography (ERT), a geophysical method sensitive to pore-fluid and pore-geometry properties, permits to gain quasi-continuous information about subsurface properties in real-time and has been consequently widely used for the characterization of hydrocarbon-impacted sediments. However, its application for the long-term monitoring of processes accompanying natural or engineered bioremediation is still difficult due to the poor understanding of the role that biogeochemical processes play in the electrical signatures. For in-situ studies, the task is further complicated by the variable signal-to-noise ratio and the variations of environmental parameters leading to resolution changes in the electrical images. In this work, we present ERT imaging results for data collected over a period of two years on a site affected by a diesel fuel contamination and undergoing bioremediation. We report low electrical resistivity anomalies in areas associated to the highest contaminant concentrations likely due transformations of the contaminant due to microbial activity and accompanying release of metabolic products. We also report large seasonal variations of the bulk electrical resistivity in the contaminated areas in correlation with temperature and groundwater level fluctuations. However, the amplitude of bulk electrical resistivity variations largely exceeds the amplitude expected given existing petrophysical models. Our results suggest that the variations in electrical properties are mainly controlled by microbial activity which in turn depends on soil temperature and hydrogeological conditions. Therefore, ERT can be suggested as

  13. Contamination effects on fixed-bias Langmuir probes

    Energy Technology Data Exchange (ETDEWEB)

    Steigies, C. T. [Institut fuer Experimentelle und Angewandte Physik, Christian-Albrechts-Universitaet zu Kiel, 24098 Kiel (Germany); Barjatya, A. [Department of Physical Sciences, Embry-Riddle Aeronautical University, Daytona Beach, Florida 32114 (United States)

    2012-11-15

    Langmuir probes are standard instruments for plasma density measurements on many sounding rockets. These probes can be operated in swept-bias as well as in fixed-bias modes. In swept-bias Langmuir probes, contamination effects are frequently visible as a hysteresis between consecutive up and down voltage ramps. This hysteresis, if not corrected, leads to poorly determined plasma densities and temperatures. With a properly chosen sweep function, the contamination parameters can be determined from the measurements and correct plasma parameters can then be determined. In this paper, we study the contamination effects on fixed-bias Langmuir probes, where no hysteresis type effect is seen in the data. Even though the contamination is not evident from the measurements, it does affect the plasma density fluctuation spectrum as measured by the fixed-bias Langmuir probe. We model the contamination as a simple resistor-capacitor circuit between the probe surface and the plasma. We find that measurements of small scale plasma fluctuations (meter to sub-meter scale) along a rocket trajectory are not affected, but the measured amplitude of large scale plasma density variation (tens of meters or larger) is attenuated. From the model calculations, we determine amplitude and cross-over frequency of the contamination effect on fixed-bias probes for different contamination parameters. The model results also show that a fixed bias probe operating in the ion-saturation region is affected less by contamination as compared to a fixed bias probe operating in the electron saturation region.

  14. Mixture effects in samples of multiple contaminants - An inter-laboratory study with manifold bioassays.

    Science.gov (United States)

    Altenburger, Rolf; Scholze, Martin; Busch, Wibke; Escher, Beate I; Jakobs, Gianina; Krauss, Martin; Krüger, Janet; Neale, Peta A; Ait-Aissa, Selim; Almeida, Ana Catarina; Seiler, Thomas-Benjamin; Brion, François; Hilscherová, Klára; Hollert, Henner; Novák, Jiří; Schlichting, Rita; Serra, Hélène; Shao, Ying; Tindall, Andrew; Tolefsen, Knut-Erik; Umbuzeiro, Gisela; Williams, Tim D; Kortenkamp, Andreas

    2018-05-01

    Chemicals in the environment occur in mixtures rather than as individual entities. Environmental quality monitoring thus faces the challenge to comprehensively assess a multitude of contaminants and potential adverse effects. Effect-based methods have been suggested as complements to chemical analytical characterisation of complex pollution patterns. The regularly observed discrepancy between chemical and biological assessments of adverse effects due to contaminants in the field may be either due to unidentified contaminants or result from interactions of compounds in mixtures. Here, we present an interlaboratory study where individual compounds and their mixtures were investigated by extensive concentration-effect analysis using 19 different bioassays. The assay panel consisted of 5 whole organism assays measuring apical effects and 14 cell- and organism-based bioassays with more specific effect observations. Twelve organic water pollutants of diverse structure and unique known modes of action were studied individually and as mixtures mirroring exposure scenarios in freshwaters. We compared the observed mixture effects against component-based mixture effect predictions derived from additivity expectations (assumption of non-interaction). Most of the assays detected the mixture response of the active components as predicted even against a background of other inactive contaminants. When none of the mixture components showed any activity by themselves then the mixture also was without effects. The mixture effects observed using apical endpoints fell in the middle of a prediction window defined by the additivity predictions for concentration addition and independent action, reflecting well the diversity of the anticipated modes of action. In one case, an unexpectedly reduced solubility of one of the mixture components led to mixture responses that fell short of the predictions of both additivity mixture models. The majority of the specific cell- and organism

  15. A proximity effect in adults' contamination intuitions

    Directory of Open Access Journals (Sweden)

    Laura R. Kim

    2011-04-01

    Full Text Available Magical beliefs about contagion via contact (Rozin, Nemeroff, Wane, and Sherrod, 1989 may emerge when people overgeneralize real-world mechanisms of contamination beyond their appropriate boundaries (Lindeman and Aarnio, 2007. Do people similarly overextend knowledge of airborne contamination mechanisms? Previous work has shown that very young children believe merely being close to a contamination source can contaminate an item (Springer and Belk 1994; we asked whether this same hyper-avoidant intuition is also reflected in adults' judgments. In two studies, we measured adults' ratings of the desirability of an object that had made contact with a source of contamination, an object nearby that had made no contact with the contaminant, and an object far away that had also made no contact. Adults showed a clear proximity effect, wherein objects near the contamination source were perceived to be less desirable than those far away, even though a separate group of adults unanimously acknowledged that contaminants could not possibly have made contact with either the nearby or far-away object (Study 1. The proximity effect also remained robust when a third group of adults was explicitly told that no contaminating particles had made contact with the objects at any time (Study 2. We discuss implications of our findings for extending the scope of magical contagion effects beyond the contact principle, for understanding the persistence of intuitive theories despite broad acceptance of science-based theories, and for constraining interpretations of the developmental work on proximity beliefs.

  16. Combining Geoelectrical Measurements and CO2 Analyses to Monitor the Enhanced Bioremediation of Hydrocarbon-Contaminated Soils: A Field Implementation

    Directory of Open Access Journals (Sweden)

    Cécile Noel

    2016-01-01

    Full Text Available Hydrocarbon-contaminated aquifers can be successfully remediated through enhanced biodegradation. However, in situ monitoring of the treatment by piezometers is expensive and invasive and might be insufficient as the information provided is restricted to vertical profiles at discrete locations. An alternative method was tested in order to improve the robustness of the monitoring. Geophysical methods, electrical resistivity (ER and induced polarization (IP, were combined with gas analyses, CO2 concentration, and its carbon isotopic ratio, to develop a less invasive methodology for monitoring enhanced biodegradation of hydrocarbons. The field implementation of this monitoring methodology, which lasted from February 2014 until June 2015, was carried out at a BTEX-polluted site under aerobic biotreatment. Geophysical monitoring shows a more conductive and chargeable area which corresponds to the contaminated zone. In this area, high CO2 emissions have been measured with an isotopic signature demonstrating that the main source of CO2 on this site is the biodegradation of hydrocarbon fuels. Besides, the evolution of geochemical and geophysical data over a year seems to show the seasonal variation of bacterial activity. Combining geophysics with gas analyses is thus promising to provide a new methodology for in situ monitoring.

  17. Comparison of surface contamination monitors for in vivo measurement of 131I in thyroid

    International Nuclear Information System (INIS)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M.

    2015-01-01

    The routine handling of radiopharmaceuticals in nuclear medicine represents a significant risk of internal exposure to the staff. The IAEA recommends the implementation of monitoring plans for all workers subject to a risk of exposures above 1 mSv per year. However, in Brazil, such recommendation is practically unfeasible due to the lack of a sufficient number of qualified internal dosimetry services over the country. This work presents an alternative based on a simple and inexpensive methodology aimed to perform in-vivo monitoring of 131 I in thyroid using portable surface contamination probes. All models evaluated showed suitable sensitivity for such application. (author)

  18. Radioactive sources and contaminated materials in scrap: monitoring, detection and remedial actions

    International Nuclear Information System (INIS)

    Gallini, R.; Berna, V.; Bonora, A.; Santini, M.

    1999-01-01

    The scrap recycling in steel and other metal mills represents one of the most relevant activities in the Province of Brescia (Lombardy, Italy). In our Province more than 20 million tonnes of metal scrap are recycled every year by a melting process. Since 1990, many accidents which took place were caused by the unwanted melting of radioactive sources, that were probably hidden in metal scrap. In 1993, the Italian Government stated directives to monitor metal scrap imported from non-EC countries because of the suspicion of the illegal traffic of radioactive materials. In 1996, a law imposed the control of all metal scrap, regardless of their origins. Since 1993, our staff have controlled thousands of railway wagons and trucks. Approximately a hundred steel mills and foundries of aluminium, cooper, brass, etc. have also been controlled and many samples have been collected (flue dust, slag, finished products). During these controls, contaminated areas have been brought to light in two warehouses (Cs 137), in 6 companies (Cs 137 and Am 241), in two landfills of industrial waste (Cs 137) and in a quarry (Cs 137). Up to now the contaminated areas have been cleaned, except for the last one. About 150 radioactive sources on contaminated materials have been found in metal scrap. We found radioactive sources of Co 60, Ra 226, Ir 192, Kr 85, Am 241, while the contamination of metals was mainly due to Ra 226. The situation described above justifies an accurate control of the amount of scrap to reduce the risk of contamination of the workers in the working areas, in the environment and in the general public. (author)

  19. Development of monitoring system for studying of radionuclide and chemical contamination level in trans boundary river basins of Caspian and Kara Seas at Russian Federation territory

    International Nuclear Information System (INIS)

    Valyaev, A.N.; Stepanets, O.V.

    2006-01-01

    Full text: Intensive and insufficiently controlled human industrial activities, ignoring regional geological and geochemical processes, resulted in considerable chemical pollution and radioactive contamination of these river's basins, where some large nuclear power plants, uranium and chemical enterprises, oil and gas productions are also located. This epidemiological and environmental situation aggravated further after USSR collapse and the establishment of new independent states due to lack of the appropriate environmental monitoring in those countries and on their near-border areas in particular, that contributed to further aggravation of the political tension and economic destabilization between transboundary countries. The environmental situation here is one of most unfavorable among world water ecosystems. In recent years different pollutants (radionuclides, toxins, organic substances and heavy metals) activate reduction processes in bottom sediments, that lead to changes in sulfur and carbon cycles, the oxygen deficit in water, to eutrophication of water reservoirs and their biological degradation. Today the development of total environmental monitoring systems is clearly necessary for operative current control, ensuring preparedness and prediction of any potential emergencies of global and local scales and their long-term effects. The objectives for presented monitoring systems are to: (1)study sources and mechanisms of chemical pollution and radioactive contamination of water basins of Volga (the largest river in Europe and Russia), Terek and Ural rivers flowed into Caspian Sea, and Ob, Irtysh and Tom ones, flowed into Kara Sea in Arctic Ocean within RF territory; (2) develop the well-ground database (DB) on contamination; (3) the using of the obtained results for the operative current trans boundary control, monitoring and protection of freshwater resources; (4) modeling of pollutant's migration. There is no way to provide solution of environmental

  20. Evaluating legacy contaminants and emerging chemicals in marine environments using adverse outcome pathways and biological effects-directed analysis

    International Nuclear Information System (INIS)

    Hutchinson, Thomas H.; Lyons, Brett P.; Thain, John E.; Law, Robin J.

    2013-01-01

    Natural and synthetic chemicals are essential to our daily lives, food supplies, health care, industries and safe sanitation. At the same time protecting marine ecosystems and seafood resources from the adverse effects of chemical contaminants remains an important issue. Since the 1970s, monitoring of persistent, bioaccumulative and toxic (PBT) chemicals using analytical chemistry has provided important spatial and temporal trend data in three important contexts; relating to human health protection from seafood contamination, addressing threats to marine top predators and finally providing essential evidence to better protect the biodiversity of commercial and non-commercial marine species. A number of regional conventions have led to controls on certain PBT chemicals over several years (termed ‘legacy contaminants’; e.g. cadmium, lindane, polycyclic aromatic hydrocarbons [PAHs] and polychlorinated biphenyls [PCBs]). Analytical chemistry plays a key role in evaluating to what extent such regulatory steps have been effective in leading to reduced emissions of these legacy contaminants into marine environments. In parallel, the application of biomarkers (e.g. DNA adducts, CYP1A-EROD, vitellogenin) and bioassays integrated with analytical chemistry has strengthened the evidence base to support an ecosystem approach to manage marine pollution problems. In recent years, however, the increased sensitivity of analytical chemistry, toxicity alerts and wider environmental awareness has led to a focus on emerging chemical contaminants (defined as chemicals that have been detected in the environment, but which are currently not included in regulatory monitoring programmes and whose fate and biological impacts are poorly understood). It is also known that natural chemicals (e.g. algal biotoxins) may also pose a threat to marine species and seafood quality. Hence complex mixtures of legacy contaminants, emerging chemicals and natural biotoxins in marine ecosystems represent

  1. The Hamburg polonium-210 case. Monitoring of internal contaminations in a malevolent act

    International Nuclear Information System (INIS)

    Dalheimer, A.; Koenig, K.; Nosske, D.; Schaefer, I.

    2009-01-01

    The dead of Alexander Litvinenko in London in the late 2006 was linked with the visit of Dimitri Kovtun. So an investigation was started by the Hamburg Police. As the presence of polonium-210 was uncertain, the action was supported by the Federal Defense against Nuclear Hazards (NGA) of the Federal Office for Radiation Protection (BfS). Radiation measurements in some flats in Hamburg confirmed the suspicion of polonium-210 contaminations. As incorporations by ingestion or inhalation could not generally be excluded, the Coordinating Office on Incorporation Monitoring of the BfS (Leitstelle Inkorporationsueberwachung des BfS) was requested to clarify this issue. The BfS office then coordinated the required bioassay analyses of urine samples carried out at four officially appointed in-vitro laboratories for incorporation monitoring. The group of people to be examined included the members of the family involved living in the contaminated flats, the emergency forces, as well as potentially exposed members of the public. The calculation of the internal dose was based on standard assumptions and also conducted by the BfS. The internal radiation doses proved to be within the range of radiation doses due to natural exposures. Retrospectively it should be stressed that the collaboration and cooperation of all institutions involved in the operation in Hamburg was extremely good despite their differing organisational structures. As a result of the incident in Hamburg various middle and long-term measures have been taken since then by the BfS Coordinating Office on Incorporation Monitoring. (orig.)

  2. Evaluating Leaf and Canopy Reflectance of Stressed Rice Plants to Monitor Arsenic Contamination

    Directory of Open Access Journals (Sweden)

    Varaprasad Bandaru

    2016-06-01

    Full Text Available Arsenic contamination is a serious problem in rice cultivated soils of many developing countries. Hence, it is critical to monitor and control arsenic uptake in rice plants to avoid adverse effects on human health. This study evaluated the feasibility of using reflectance spectroscopy to monitor arsenic in rice plants. Four arsenic levels were induced in hydroponically grown rice plants with application of 0, 5, 10 and 20 µmol·L−1 sodium arsenate. Reflectance spectra of upper fully expanded leaves were acquired over visible and infrared (NIR wavelengths. Additionally, canopy reflectance for the four arsenic levels was simulated using SAIL (Scattering by Arbitrarily Inclined Leaves model for various soil moisture conditions and leaf area indices (LAI. Further, sensitivity of various vegetative indices (VIs to arsenic levels was assessed. Results suggest that plants accumulate high arsenic amounts causing plant stress and changes in reflectance characteristics. All leaf spectra based VIs related strongly with arsenic with coefficient of determination (r2 greater than 0.6 while at canopy scale, background reflectance and LAI confounded with spectral signals of arsenic affecting the VIs’ performance. Among studied VIs, combined index, transformed chlorophyll absorption reflectance index (TCARI/optimized soil adjusted vegetation index (OSAVI exhibited higher sensitivity to arsenic levels and better resistance to soil backgrounds and LAI followed by red edge based VIs (modified chlorophyll absorption reflectance index (MCARI and TCARI suggesting that these VIs could prove to be valuable aids for monitoring arsenic in rice fields.

  3. Integrating Individual-Based Indices of Contaminant Effects

    Directory of Open Access Journals (Sweden)

    Christopher L. Rowe

    2001-01-01

    Full Text Available Habitat contamination can alter numerous biological processes in individual organisms. Examining multiple individual-level responses in an integrative fashion is necessary to understand how individual health or fitness reflects environmental contamination. Here we provide an example of such an integrated perspective based upon recent studies of an amphibian (the bullfrog, Rana catesbeiana that experiences several, disparate changes when larval development occurs in a trace element�contaminated habitat. First, we present an overview of studies focused on specific responses of individuals collected from, or transplanted into, a habitat contaminated by coal combustion residues (CCR. These studies have reported morphological, behavioral, and physiological modifications to individuals chronically interacting with sediments in the CCR-contaminated site. Morphological abnormalities in the oral and tail regions in contaminant-exposed individuals influenced other properties such as grazing, growth, and swimming performance. Behavioral changes in swimming activities and responses to stimuli appear to influence predation risk in the contaminant-exposed population. Significant changes in bioenergetics in the contaminated habitat, evident as abnormally high energetic expenditures for survival (maintenance costs, may ultimately influence production pathways (growth, energy storage in individuals. We then present a conceptual model to examine how interactions among the affected systems (morphological, behavioral, physiological may ultimately bring about more severe effects than would be predicted if the responses were considered in isolation. A complex interplay among simultaneously occurring biological changes emerges in which multiple, sublethal effects ultimately can translate into reductions in larval or juvenile survival, and thus reduced recruitment of juveniles into the population. In systems where individuals are exposed to low concentrations of

  4. Effect-directed analysis supporting monitoring of aquatic ...

    Science.gov (United States)

    Aquatic environments are often contaminated with complex mixtures of chemicals that may pose a risk to ecosystems and human health. This contamination cannot be addressed with target analysis alone but tools are required to reduce this complexity and identify those chemicals that might cause adverse effects. Effect-directed analysis (EDA) is designed to meet this challenge and faces increasing interest in water and sediment quality monitoring. Thus, the present paper summarizes current experience with the EDA approach and the tools required,and provides practical advice on their application. The paper highlights the need for proper problem formulation and gives general advice for study design. As the EDA approach is directed by toxicity, basic principles for the selection of bioassays are given as well as a comprehensive compilation of appropriate assays, includingtheir strengths andweaknesses. A specific focus is given to strategies for sampling, extraction and bioassay dosing since they strongly impact prioritization of toxicants in EDA. Reduction of sample complexity mainly relies onfractionation procedures, which are discussed in this paper, including quality assurance and quality control. Automated combinations of fractionation, biotesting and chemical analysis using so-called hyphenated tools can enhance the throughput and might reduce the risk of artifacts in laboratory work. The key to determiningthe chemical structures causing effects is analytical toxi

  5. Effect of biodegradable amendments on uranium solubility in contaminated soils

    Energy Technology Data Exchange (ETDEWEB)

    Duquene, L. [Belgian Nuclear Research Centre, Environment Health and Safety, Biosphere Impact Studies, Boeretang 200, 2400 Mol (Belgium)], E-mail: lduquene@sckcen.be; Tack, F.; Meers, E. [Ghent University, Laboratory for Analytical Chemistry and Applied Ecochemistry, Coupure Links 653, B-9000 Gent (Belgium); Baeten, J. [Katholieke Hogeschool Kempen, Departement of Health-Care and Chemistry, Kleinhoefstraat 4, B-2440 Geel (Belgium); Wannijn, J.; Vandenhove, H. [Belgian Nuclear Research Centre, Environment Health and Safety, Biosphere Impact Studies, Boeretang 200, 2400 Mol (Belgium)

    2008-02-25

    Chelate-assisted phytoextraction has been proposed as a potential tool for phytoremediation of U contaminated sites. In this context, the effects of five biodegradable amendments on U release in contaminated soils were evaluated. Three soils were involved in this study, one with a relatively high background level of U, and two which were contaminated with U from industrial effluents. Soils were treated with 5 mmol kg{sup -1} dry weight of either citric acid, NH{sub 4}-citrate/citric acid, oxalic acid, S,S-ethylenediamine disuccinic acid or nitrilotriacetic acid. Soil solution concentration of U was monitored during 2 weeks. All amendments increased U concentration in soil solution, but citric acid and NH{sub 4}-citrate/citric acid mixture were most effective, with up to 479-fold increase. For oxalic acid, S,S-ethylenediamine disuccinic acid and nitrilotriacetic acid, the increase ranged from 10-to 100-fold. The highest concentrations were observed 1 to 7 days after treatment, after which U levels in soil solution gradually decreased. All amendments induced a temporary increase of soil solution pH and TOC that could not be correlated with the release of U in the soil solution. Thermodynamic stability constants (log K) of complexes did not predict the relative efficiency of the selected biodegradable amendments on U release in soil solution. Amendments efficiency was better predicted by the relative affinity of the chelate for Fe compared to U.

  6. Ecological effects of contaminants and remedial actions in Bear Creek

    Energy Technology Data Exchange (ETDEWEB)

    Southworth, G.R.; Loar, J.M.; Ryon, M.G.; Smith, J.G.; Stewart, A.J. (Oak Ridge National Lab., TN (United States)); Burris, J.A. (C. E. Environmental, Inc., Tallahassee, FL (United States))

    1992-01-01

    Ecological studies of the Bear Creek watershed, which drains the area surrounding several Oak Ridge Y-12 Plant waste disposal facilities, were initiated in May 1984 and are continuing at present. These studies consisted of an initial, detailed characterization of the benthic invertebrate and fish communities in Bear Creek, and they were followed by a presently ongoing monitoring phase that involves reduced sampling intensities. The characterization phase utilized two approaches: (1) instream sampling of benthic invertebrate and fish communities in Bear Creek to identify spatial and temporal patterns in distribution and abundance and (2) laboratory bioassays on water samples from Bear Creek and selected tributaries to identify potential sources of toxicity to biota. The monitoring phase of the ecological program relates to the long-term goals of identifying and prioritizing contaminant sources and assessing the effectiveness of remedial actions. It continues activities of the characterization phase at less frequent intervals. The Bear Greek Valley is a watershed that drains the area surrounding several closed Oak Ridge Y-12 Plant waste disposal facilities. Past waste disposal practices in Bear Creek Valley resulted in contamination of Bear Creek and consequent ecological damage. Extensive remedial actions have been proposed at waste sites, and some of the have been implemented or are now underway. The proposed study plan consists of an initial, detailed characterization of the benthic invertebrate and fish communities in Bear Creek in the first year followed by a reduction in sampling intensity during the monitoring phase of the plan. The results of sampling conducted from May 1984 through early 1989 are presented in this report.

  7. Ecological effects of contaminants and remedial actions in Bear Creek

    International Nuclear Information System (INIS)

    Southworth, G.R.; Loar, J.M.; Ryon, M.G.; Smith, J.G.; Stewart, A.J.; Burris, J.A.

    1992-01-01

    Ecological studies of the Bear Creek watershed, which drains the area surrounding several Oak Ridge Y-12 Plant waste disposal facilities, were initiated in May 1984 and are continuing at present. These studies consisted of an initial, detailed characterization of the benthic invertebrate and fish communities in Bear Creek, and they were followed by a presently ongoing monitoring phase that involves reduced sampling intensities. The characterization phase utilized two approaches: (1) instream sampling of benthic invertebrate and fish communities in Bear Creek to identify spatial and temporal patterns in distribution and abundance and (2) laboratory bioassays on water samples from Bear Creek and selected tributaries to identify potential sources of toxicity to biota. The monitoring phase of the ecological program relates to the long-term goals of identifying and prioritizing contaminant sources and assessing the effectiveness of remedial actions. It continues activities of the characterization phase at less frequent intervals. The Bear Greek Valley is a watershed that drains the area surrounding several closed Oak Ridge Y-12 Plant waste disposal facilities. Past waste disposal practices in Bear Creek Valley resulted in contamination of Bear Creek and consequent ecological damage. Extensive remedial actions have been proposed at waste sites, and some of the have been implemented or are now underway. The proposed study plan consists of an initial, detailed characterization of the benthic invertebrate and fish communities in Bear Creek in the first year followed by a reduction in sampling intensity during the monitoring phase of the plan. The results of sampling conducted from May 1984 through early 1989 are presented in this report

  8. Concentrations of elements in fish fillets, fish muscle plugs, and crayfish from the 2007 Missouri Department of Conservation General Contaminant Monitoring Program

    Science.gov (United States)

    May, Thomas W.; Walther, Michael J.; Brumbaugh, William G.; McKee, Michael J.

    2009-01-01

    This report presents the results of a contaminant monitoring survey conducted annually by the Missouri Department of Conservation to examine the levels of selected elemental contaminants in fish fillets, fish muscle plugs, and crayfish. Fillets of channel catfish (Ictalurus punctatus), bass (Micropterus salmoides, Micropterus dolomieu, Morone chrysops), walleye (Sander vitreus), common carp (Cyprinus carpio), lake sturgeon (Acipenser fulvescens), northern hog sucker (Hypentelium nigricans), and rainbow trout (Oncorhynchus mykiss) were collected from 21 sites as part of the Department's Fish Contaminant Monitoring Program. Long-pincered crayfish (Orconectes longidigitus) were collected from one site to assess trophic transfer of metals to fish. Fish muscle plugs were collected from smallmouth bass (Micropterus dolomieu) at two different locations from one site.

  9. Long-term ERT monitoring of biogeochemical changes of an aged hydrocarbon contamination.

    Science.gov (United States)

    Caterina, David; Flores Orozco, Adrian; Nguyen, Frédéric

    2017-06-01

    Adequate management of contaminated sites requires information with improved spatio-temporal resolution, in particular to assess bio-geochemical processes, such as the transformation and degradation of contaminants, precipitation of minerals or changes in groundwater geochemistry occurring during and after remediation procedures. Electrical Resistivity Tomography (ERT), a geophysical method sensitive to pore-fluid and pore-geometry properties, permits to gain quasi-continuous information about subsurface properties in real-time and has been consequently widely used for the characterization of hydrocarbon-impacted sediments. However, its application for the long-term monitoring of processes accompanying natural or engineered bioremediation is still difficult due to the poor understanding of the role that biogeochemical processes play in the electrical signatures. For in-situ studies, the task is further complicated by the variable signal-to-noise ratio and the variations of environmental parameters leading to resolution changes in the electrical images. In this work, we present ERT imaging results for data collected over a period of two years on a site affected by a diesel fuel contamination and undergoing bioremediation. We report low electrical resistivity anomalies in areas associated to the highest contaminant concentrations likely due transformations of the contaminant due to microbial activity and accompanying release of metabolic products. We also report large seasonal variations of the bulk electrical resistivity in the contaminated areas in correlation with temperature and groundwater level fluctuations. However, the amplitude of bulk electrical resistivity variations largely exceeds the amplitude expected given existing petrophysical models. Our results suggest that the variations in electrical properties are mainly controlled by microbial activity which in turn depends on soil temperature and hydrogeological conditions. Therefore, ERT can be suggested as

  10. Soil moisture effects during bioventing in fuel-contaminated arid soils

    International Nuclear Information System (INIS)

    Zwick, T.C.; Leeson, A.; Hinchee, R.E.; Hoeppel, R.E.; Bowling, L.

    1995-01-01

    This study evaluated the effects of soil moisture addition on microbial activity during bioventing of dry, sandy soils at the Marine Corps Air Ground Combat Center (MCAGCC), Twentynine Palms, California. Soils at the site have been contaminated to a depth of approximately 80 ft (24 m) with gasoline, JP-5 jet fuel, and diesel fuel. Based on the low soil moisture measured at the site (2 to 3% by weight), it was determined that soil moisture may be limiting biodegradation. To evaluate the effect that moisture addition had on microbial activity under field conditions, a subsurface drip irrigation system was installed above the fuel hydrocarbon plume. Irrigation water was obtained from two monitoring wells on the site, where groundwater was approximately 192 ft (59 m) below ground surface. Advancement of the wetting front was monitored. In situ respiration rates increased significantly after moisture addition. The results of this study provide evidence for the potential applicability of moisture addition in conjunction with bioventing for site remediation in arid environments. Further work is planned to investigate optimization of moisture addition

  11. Alpha contamination assessment for D ampersand D activities: Monitoring pipe interiors

    International Nuclear Information System (INIS)

    Rawool-Sullivan, M.W.; Conaway, J.G.; MacArthur, D.W.; Vaccarella, J.

    1996-02-01

    We have developed a prototype instrument capable of assessing alpha-emitting contamination on interior surfaces of ducts, pipes, tanks, and other enclosed volumes without inserting a probe. Air is drawn through the potentially contaminated volume and then through a detection grid, where ions created in the air by alpha particles are collected and the resulting charge measured with a sensitive electrometer. A filter at the intake end of the contaminated volume excludes externally created ions, so only ions generated inside the volume are detected. We have studied the response of this prototype in initial experiments using calibrated alpha sources with various pipe diameters and configurations, air flows, and source locations in the pipes. The results of these experiments indicate that this method can be an effective approach to assessing internal contamination

  12. Nearshore and offshore environmental effects monitoring at the Sable Offshore Energy project

    International Nuclear Information System (INIS)

    Hurley, G. V.

    2000-01-01

    A monitoring program to determine whether any temporary or permanent environmental perturbations may be attributable to the Sable offshore gas pipeline project as it approaches landfall at Goldboro through an outer bay is discussed, This nearshore region is an active fishing region for the residents of Goldboro, hence the concern about possible contamination. The monitoring project began with a baseline study, followed by monitoring the construction and the recovery period following construction, to ensure that any persistent changes to the nearshore aquatic environment were documented. The monitoring study included representatives of the fishing community to ensure that concerns are addressed early and on a continuing basis. At various phases of the project water properties,sediment modelling, the effects of construction on sea bottom conditions, benthic biota and cultivated mussels, water quality, phytoplankton, and resuspension of toxic cysts, terns and other seabirds were studied. Monitoring programs were also established for sea urchins and mussels, two important commercial species. Commercial-sized sea urchins showed a decrease of 60 per cent between 1998 and 1999 (i.e. the construction period). Recovery of sea urchin population in the immediate trench region will be the special focus of the post-construction monitoring phase. Mussel spat settlement and mussel tissue condition, lobster trapping, water properties, and bird behaviour showed no measurable changes during construction monitoring. In addition to these studies there is an ongoing offshore monitoring program in effect by Sable Offshore Energy Inc., put in place as a condition of approval of its Development Plan by the Canada-Nova Scotia Offshore Petroleum Board. This program monitors attributes such as water quality, suspended particulate matter in the benthic boundary layer, sediment quality, the benthic habitat and megafaunal community, shellfish body burden and taint, marine mammals and seabirds

  13. Evaluating Monitoring Strategies to Detect Precipitation-Induced Microbial Contamination Events in Karstic Springs Used for Drinking Water

    Directory of Open Access Journals (Sweden)

    Michael D. Besmer

    2017-11-01

    Full Text Available Monitoring of microbial drinking water quality is a key component for ensuring safety and understanding risk, but conventional monitoring strategies are typically based on low sampling frequencies (e.g., quarterly or monthly. This is of concern because many drinking water sources, such as karstic springs are often subject to changes in bacterial concentrations on much shorter time scales (e.g., hours to days, for example after precipitation events. Microbial contamination events are crucial from a risk assessment perspective and should therefore be targeted by monitoring strategies to establish both the frequency of their occurrence and the magnitude of bacterial peak concentrations. In this study we used monitoring data from two specific karstic springs. We assessed the performance of conventional monitoring based on historical records and tested a number of alternative strategies based on a high-resolution data set of bacterial concentrations in spring water collected with online flow cytometry (FCM. We quantified the effect of increasing sampling frequency and found that for the specific case studied, at least bi-weekly sampling would be needed to detect precipitation events with a probability of >90%. We then proposed an optimized monitoring strategy with three targeted samples per event, triggered by precipitation measurements. This approach is more effective and efficient than simply increasing overall sampling frequency. It would enable the water utility to (1 analyze any relevant event and (2 limit median underestimation of peak concentrations to approximately 10%. We conclude with a generalized perspective on sampling optimization and argue that the assessment of short-term dynamics causing microbial peak loads initially requires increased sampling/analysis efforts, but can be optimized subsequently to account for limited resources. This offers water utilities and public health authorities systematic ways to evaluate and optimize their

  14. Monitoring pesticides residues and contaminants for some leafy vegetables at the market level

    International Nuclear Information System (INIS)

    Ibrahim, A. B. H.

    2004-03-01

    Pesticide residues and contaminants in selected leafy vegetables, namely (lettuce, garden rocket and salad onion) were monitored at market level in Riyadh City in Saudi Arabia, during the period june to july 2001. Fifteen samples of vegetables from the City vegetable market of Riyadh were collected and subjected to multi-pesticide residue detection and analysis by gas chromatography with mass spectrometer and electron capture detectors (GC/MS,ECD). Results of sample extracts analysis showed that the two vegetables of: garden rocket and salad onion contain pesticide residues and contaminants which have no Maximum Residue Limits (MRL) prescribed by Codex Alimentarius Commission (CAC) collaborate with World Health and Food and Agriculture Organizations (WHO/FAO). Whereas lettuce vegetable was found free of any identified pesticide residues or contaminants. Garden rocket was shown to contain dibutyl phthalate (0.04 ppm)-steryl chloride (0.02 ppm) tridecane (0.06 ppm)-hexadecane (0.07 ppm)-BIS (ethylhexyl) phthalate (0.006 ppm) and pyridinium, 1-hexyl chloride (0.01 ppm). The salad onion was found to contain 9-octadecanamide (0.13 ppm)-tridecane (0.15 ppm) and tetradecane (0.16 ppm). There are no established MRL s for these pesticides and contaminants detected in garden rocket and salad onion, although when impacts on human health were reviewed some of them were found probably hazardous. (Author)

  15. Confirmatory research program: effects of atmospheric contaminants on commercial charcoals

    International Nuclear Information System (INIS)

    Bellamy, R.R.; Dietz, V.R.

    1979-01-01

    The increased use of activated charcoals in engineered-safety-feature and normal ventilation systems of nuclear power stations to continually remove radioiodine from flowing air prior to release to the environment has added importance to the question of the effect of atmospheric contaminants on the useful life of the charcoal. In January of 1977 the Naval Research Laboratory (NRL) began an investigation to determine the extent to which atmospheric contaminants in ambient concentrations degrade the efficiency of various commercially-available charcoals for removing methyl iodide. The approach employed by NRL is two-fold. First, charcoal samples are exposed to unmodified outdoor air for periods of one to nine months, then examined for methyl iodide retention, increase in weight, and the pH of water extract. The atmospheric contaminants are identified by the NRL Air Quality Monitoring Station, and concentrations of the various contaminants (ozone, SO 2 , NO 2 , CO 2 , methane and total hydrocarbons) are also available. Second, additional charcoal samples are exposed to the same pollutants under controlled laboratory conditions in various pollutant combinations. Results indicate that the water vapor-charcoal interaction is an important factor in the degradation of the commercial charcoals. Laboratory results indicate the pollutant sulfur dioxide plus water vapor can result in significant charcoal deterioration, as did ozone plus water vapor. Conversely, carbon monoxide did not appear to affect the charcoal. Also, differences were observed for various charcoals

  16. Cholinesterase activities in the scallop Pecten jacobaeus: Characterization and effects of exposure to aquatic contaminants

    International Nuclear Information System (INIS)

    Stefano, Bonacci; Ilaria, Corsi; Silvano, Focardi

    2008-01-01

    Nearshore marine environments of industrialized countries are increasingly threatened by anthropogenic pollution. It is therefore a priority task to investigate the sensitivity of new ecotoxicological warning signals of the occurrence and effects of aquatic pollutants. The main aims of the present study were: 1) to characterize the biochemical properties of ChEs in tissues of the bivalve Pecten jacobaeus, using different specific substrates and selective inhibitors; 2) to measure sensitivity of ChE activities to in vitro exposure to the OPs azamethiphos and DFP and to the heavy metals cadmium and zinc. Our final aim was to carry out a preliminary evaluation of the suitability of ChEs measurement in tissues of the scallop for monitoring marine environmental quality and neurotoxic compounds contamination in the Mediterranean Sea. Responses to specific inhibitors have suggested that ChEs in adductor muscle share many characteristics with vertebrate acetylcholinesterase. Dose-dependent inhibition of ChE was observed in response to in vitro exposure to environmental contaminants such as cadmium and azamethiphos. Sensitivity to zinc and DFP was lower. ChEs in P. jacobaeus might therefore have potential as a sensitive biomarker for monitoring marine pollution. Results of the present study will be useful to focus further experiment of exposure to pollutants under in vivo conditions. Capsule: Cholinesterase activities in scallop Pecten jacobaeus were observed to be sensitive to contaminants in vitro and may therefore have potential as biomarkers for monitoring water pollution

  17. Cholinesterase activities in the scallop Pecten jacobaeus: Characterization and effects of exposure to aquatic contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Stefano, Bonacci [Department of Environmental Sciences ' G. Sarfatti' , University of Siena, Via P.A. Mattioli 4, I-53100 Siena (Italy)], E-mail: bonacci@unisi.it; Ilaria, Corsi [Department of Environmental Sciences ' G. Sarfatti' , University of Siena, Via P.A. Mattioli 4, I-53100 Siena (Italy)], E-mail: corsii@unisi.it; Silvano, Focardi [Department of Environmental Sciences ' G. Sarfatti' , University of Siena, Via P.A. Mattioli 4, I-53100 Siena (Italy)], E-mail: focardi@unisi.it

    2008-03-15

    Nearshore marine environments of industrialized countries are increasingly threatened by anthropogenic pollution. It is therefore a priority task to investigate the sensitivity of new ecotoxicological warning signals of the occurrence and effects of aquatic pollutants. The main aims of the present study were: 1) to characterize the biochemical properties of ChEs in tissues of the bivalve Pecten jacobaeus, using different specific substrates and selective inhibitors; 2) to measure sensitivity of ChE activities to in vitro exposure to the OPs azamethiphos and DFP and to the heavy metals cadmium and zinc. Our final aim was to carry out a preliminary evaluation of the suitability of ChEs measurement in tissues of the scallop for monitoring marine environmental quality and neurotoxic compounds contamination in the Mediterranean Sea. Responses to specific inhibitors have suggested that ChEs in adductor muscle share many characteristics with vertebrate acetylcholinesterase. Dose-dependent inhibition of ChE was observed in response to in vitro exposure to environmental contaminants such as cadmium and azamethiphos. Sensitivity to zinc and DFP was lower. ChEs in P. jacobaeus might therefore have potential as a sensitive biomarker for monitoring marine pollution. Results of the present study will be useful to focus further experiment of exposure to pollutants under in vivo conditions. Capsule: Cholinesterase activities in scallop Pecten jacobaeus were observed to be sensitive to contaminants in vitro and may therefore have potential as biomarkers for monitoring water pollution.

  18. Reference sources for the calibration of surface contamination monitors - Beta-emitters (maximum beta energy greater than MeV) and alpha-emitters (International Standard Publication ISO 8769:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    This International Standard specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters and to beta-emitters of maximum beta energy greater than 0,15 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC Publication 325 and other documents. This International Standard specifies reference radiations for the calibration of surface contamination monitors which take the form of adequately characterized large area sources specified, without exception, in terms of activity and surface emission rate, the evaluation of these quantities being traceable to national standards

  19. Efficacy monitoring of in situ fuel bioremediation

    International Nuclear Information System (INIS)

    Mueller, J.; Borchert, S.; Heard, C.

    1996-01-01

    The wide-scale, multiple-purpose use of fossil fuels throughout the industrialized world has resulted in the inadvertent contamination of myriad environments. Given the scope and magnitude of these environmental contamination problems, bioremediation often represents the only practical and economically feasible solution. This is especially true when depth of contamination, magnitude of the problem, and nature of contaminated material preclude other remedial actions, short of the no-response alternative. From the perspective, the effective, safe and scientifically valid use of in situ bioremediation technologies requires cost-efficient and effective implementation strategies in combination with unequivocal approaches for monitoring efficacy of performance. Accordingly, with support from the SERDP program, the authors are field-testing advanced in situ bioremediation strategies and new approaches in efficacy monitoring that employ techniques instable carbon and nitrogen isotope biogeochemistry. One field demonstration has been initiated at the NEX site in Port Hueneme, CA (US Navy's National Test Site). The objectives are: (1) to use stable isotopes as a biogeochemical monitoring tool for in situ bioremediation of refined petroleum (i.e., BTEX), and (2) to use vertical groundwater circulation technology to effect in situ chemical containment and enhanced in situ bioremediation

  20. Use of liquid nitrogen during storage in a cell and tissue bank: contamination risk and effect on the detectability of potential viral contaminants.

    Science.gov (United States)

    Mirabet, Vicente; Alvarez, Manuel; Solves, Pilar; Ocete, Dolores; Gimeno, Concepción

    2012-04-01

    Cryopreservation is widely used for banking cells and tissues intended for transplantation. Liquid nitrogen provides a very stable ultra-low temperature environment. Thus, it is used for longterm storage. Unlike the exhaustive microbiological monitoring of the environmental conditions during tissue processing, storage is not usually considered as a critical point of potential contamination risk in professional standards for cell and tissue banking. We have analysed the presence of microbial agents inside our nitrogen tanks. We have mainly detected environmental and water-borne bacteria and fungi. In addition, we have studied the effect of liquid nitrogen exposure on virus detectability. Only differences for hepatitis C virus RNA were observed. Measures for contamination risk reduction during storage must be mandatory in cell and tissue banking. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. The radioecological monitoring of the some water ecosystems of the contaminated districts of Belarus

    International Nuclear Information System (INIS)

    Khvalej, O.D.; Dackevich, P.I.; Komissarov, F.D.; Basharina, L.P.

    2002-01-01

    The main results of the long-term radioecological monitoring of the some water ecosystems of the contaminated districts of Belarus are presented. The main components of water ecosystem (water, suspensions, bottom sediments, water vegetation) were observed. The migration of Cs 137 and Sr 90 on the water-collection areas were investigated in detail. The tendency of Sr 90 increasing in the components of the surface water systems is observed

  2. 1998 Comprehensive TNX Area Annual Groundwater and Effectiveness Monitoring Report

    Energy Technology Data Exchange (ETDEWEB)

    Chase, J.

    1999-06-02

    Shallow groundwater beneath the TNX Area at the Savannah River Site has been contaminated with chlorinated volatile organic compounds such as trichloroethylene and carbon tetrachloride. The Interim Action T-1 Air Stripper System began operation on September 16, 1996. A comprehensive groundwater monitoring program was initiated to measure the effectiveness of the system. The Interim Action is meeting its objectives and is capable of continuing to do so until the final groundwater remedial action is in place.

  3. Eco-monitoring of highly contaminated areas: historic heavy metal contamination in tree ring records

    Science.gov (United States)

    Baross, Norbert; Jordán, Győző; Albert, Julianna; Abdaal, Ahmed; Anton, Attila

    2014-05-01

    This study examines and compares tree rings of trees grown in a mining area highly contaminated with heavy metals. Tree rings offers an excellent opportunity for eco-monitoring polluted areas. Contamination dispersion from the source to the receptors can be studied in time and space. The sampled area is located in the eastern part of the Matra Mts. of the Inner-Carpathian calc-alkaline Volcanic Arc (Hungary) with abundant historical ore (Pb, Zn, Cu, etc.) mining in the area. Dense forests are composed of the most typical association of the Turkey oak (Quercus cerris). Scots pine (Pinus sylvestris), European black pine (Pinus nigra), oak (Quercus robur), beech (Fagus sylvatica), and hornbeam (Carpinus betulus) also occurs in the landscape. Sampled trees are located within a 1km radius of the abandoned historic ore mines. Sample sites were located above the old mines and waste rock heaps, under the waste rock heaps and on the floodplain of the Ilona Creek. The sampled trees were selected by the following criteria: the tree should be healthy, showing no signs of thunderbolt or diseases and having a minimum diameter of 50 cm. Samples were taken with a tree borer at the height of 150 cm. At the same time, soil samples were also taken near the trees in a 25 cm depth. Prior to laboratory analysis, the samples measured and air dried. Every fifth years tree ring was taken from the samples under microscope, working backwards from the most recent outer ring (2012, the year of the sampling). Samples were digested with a mixture of H2SO4 and H2O2m in Teflon vessels in a microwave unit. The samples were analyzed by ICP-OES instrument. The results were evaluated with statistical method. Results revealed a consistent picture showing distinct locations and years of the contamination history in the former mining area. Some elements are built into the trees more efficiently than other elements depending on mobility in the soil solution that is influenced by soil chemical properties

  4. ICPP digital wide area portal monitor

    International Nuclear Information System (INIS)

    Nichols, C.E.

    1978-01-01

    A portal montior is described which is used to check personnel for contamination. The monitor is extremely sensitive. In addition to personnel contamination control, it serves as an extremely effective SNM detector capable of detecting U-235 in half the quantities specified in Federal Standards

  5. Immunotoxicological effects of environmental contaminants on marine bivalves.

    Science.gov (United States)

    Renault, T

    2015-09-01

    Coastal areas are complex environments frequently contaminated by numerous pollutants that represent a potential threat to marine organisms, especially bivalves. These pollutants may have major ecological consequences. Although effects of different environmental contaminants on the immune system in marine bivalves have been already reported, a few of reviews summarizes these effects. The main purpose of this chapter relies on summarizing recent body of data on immunotoxicity in bivalves subjected to contaminants. Immune effects of heavy metals, pesticides, HAP, PCB and pharmaceuticals are presented and discussed and a particular section is devoted to nanoparticle effects. A large body of literature is now available on this topic. Finally, the urgent need of a better understanding of complex interactions between contaminants, marine bivalves and infectious diseases is noticed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Monitoring of Radionuclide Contamination in Food Samples in Malaysia due to Daiichi Reactor Accident in Fukushima, Japan

    International Nuclear Information System (INIS)

    Nurrul Assyikeen Mohd Jaffary; Wo, Y.M.; Abdul Kadir Ishak

    2015-01-01

    On March 11, 2011, a serious accident occurred in Daiichi nuclear reactor plant, Fukushima, Japan which caused radioactive materials been released into the atmosphere in the form of aerosols and dust particles. Sea water around the plant was also found contaminated with high radioactivity readings. These radioactive materials could be transported by the winds and ocean current across international borders and cannot be controlled by human. Thus, a continuous monitoring activity of radionuclide content in the air and sea water needs to be conducted by the authorities. In addition to radioactivity monitoring, Malaysia should also control the entry of contaminated food in order to prevent radionuclide ingestion by human. The radionuclide 131 I, 134 Cs and 137 Cs were used as a measure of pollution levels and counted with gamma spectrometry using standard analysis method suggested by AOAC International. In this paper, details description of the role of Radiochemical and Environment Group, Nuclear Malaysia who is responsible in analyzing the radioactivity in the food samples due to Fukushima Daiichi, Japan accident was included. The radioactivity limit adopted and analysis results from this monitoring were discussed. (author)

  7. Instrument evaluation no. 18. Mini instruments contamination meter type 5.10 EL

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1980-04-01

    An evaluation is given of the general purpose contamination monitor, the Mini-Instruments Type 5-10EL which comprises a probe connected by a coiled extensible cable to a ratemeter. The facilities and controls, radiation characteristics, electrical characteristics, environmental effects, mechanical characteristics, and the manual are considered. A summary is given of the instrument's performance showing that it is a useful general-purpose contamination monitor suitable for the monitoring of beta contamination at a level for non-active areas of 1 DL (3.7 Bq cm -2 (10 -4 μCi cm -2 )) for beta emitters of maximum energy at least that of 14 C, given a normal environmental gamma background. (U.K.)

  8. Monitoring of airborne contamination during the handling of technetium-99m and radioiodine

    International Nuclear Information System (INIS)

    Eadie, A.S.; Horton, P.W.; Hilditch, T.E.

    1980-01-01

    Measurements have been made using an air sampler to measure airborne radioactivity produced during the routine handling of large activities of technetium-99m, iodine-125 and iodine-131. The results indicate that 99 Tcsup(m) can be safely handled in environments without direct exhaust of the ventilated air but that 125 I and 131 I should always be handled in a ventilated environment such as a fume cupboard or a down-draught work-station of the total-exhaust type. Monitoring of thyroid uptake proves to be the most reliable means of monitoring airborne contamination by these radionuclides, but burdens and radiation doses for typical procedures are well within the maximum permissible limits of the Code of Practice for the Protection of Persons from Ionizing Radiation arising from Medical and Dental Use. (author)

  9. Pressure monitoring and characterization of external sources of contamination at the site of the payment drinking water epidemiological studies.

    Science.gov (United States)

    Besner, Marie-Claude; Broséus, Romain; Lavoie, Jean; Giovanni, George Di; Payment, Pierre; Prévost, Michèle

    2010-01-01

    The 1990s epidemiological studies by Payment and colleagues suggested that an increase in gastrointestinal illnesses observed in the population consuming tap water from a system meeting all water quality regulations might be associated with distribution system deficiencies. In the current study, the vulnerability of this distribution system to microbial intrusion was assessed by characterizing potential sources of contamination near pipelines and monitoring the frequency and magnitude of negative pressures. Bacterial indicators of fecal contamination were recovered more frequently in the water from flooded air-valve vaults than in the soil or water from pipe trenches. The level of fecal contamination in these various sources was more similar to levels from river water rather than wastewater. Because of its configuration, this distribution system is vulnerable to negative pressures when pressure values out of the treatment plant reach or drop below 172 kPa (25 psi), which occurred nine times during a monitoring period of 17 months. The results from this investigation suggest that this distribution system is vulnerable to contamination by intrusion. Comparison of the frequency of occurrence of negative pressure events and repair rates with data from other distribution systems suggests that the system studied by Payment and colleagues is not atypical.

  10. Surface Contamination Monitor and Survey Information Management System

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    Shonka Research Associates, Inc.`s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East`s (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies.

  11. Surface Contamination Monitor and Survey Information Management System

    International Nuclear Information System (INIS)

    1998-02-01

    Shonka Research Associates, Inc.'s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East's (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies

  12. Gulf of Mexico offshore operations monitoring experiment (GOOMEX), phase I : sublethal responses to contaminant exposure - introduction and overview

    International Nuclear Information System (INIS)

    Kennicutt, M.C.; Green, R.H.; Montagna, P.

    1996-01-01

    The Gulf of Mexico Offshore Operations Monitoring Experiment (GOOMEX) is a three-phase study to test and evaluate a range of biological, biochemical, and chemical methodologies to detect and assess chronic sublethal biological impacts in the vicinity of long-duration activities associated with oil and gas exploration and production. A chronic impact is defined as an effect on the biota caused by exposure to the long-term accumulation of chemicals in the environment. The basic program, comprising four field activities over a 2-yr period, was designed to detect nearfield impacts and contaminant gradients extending out from each site. Five test sites were evaluated and three selected as most appropriate for long-term study: MU-A85, MAI-686, and HI-A389. The sampling design included a radial pattern with stations at 30-50, 100, 200, 500, and 3000 m distance and employed a dose-response model to test the hypotheses that biological, chemical, and biochemical variations are due to platform-derived contaminants. Study components included contaminant (trace metals and hydrocarbons) analysis in sediments, pore waters, and biological tissues; assemblage analysis of benthic meiofauna, infauna, and epifauna, assessment of community health based on life history and reproduction studies; and the induction of detoxification responses. (author). 57 refs., 9 tabs., 5 figs

  13. Comparison of the effectiveness of soil heating prior or during in situ chemical oxidation (ISCO) of aged PAH-contaminated soils.

    Science.gov (United States)

    Ranc, Bérénice; Faure, Pierre; Croze, Véronique; Lorgeoux, Catherine; Simonnot, Marie-Odile

    2017-04-01

    Thermal treatments prior or during chemical oxidation of aged polycyclic aromatic hydrocarbon (PAH)-contaminated soils have already shown their ability to increase oxidation effectiveness. However, they were never compared on the same soil. Furthermore, oxygenated polycyclic aromatic hydrocarbons (O-PACs), by-products of PAH oxidation which may be more toxic and mobile than the parent PAHs, were very little monitored. In this study, two aged PAH-contaminated soils were heated prior (60 or 90 °C under Ar for 1 week) or during oxidation (60 °C for 1 week) with permanganate and persulfate, and 11 O-PACs were monitored in addition to the 16 US Environmental Protection Agency (US EPA) PAHs. Oxidant doses were based on the stoichiometric oxidant demand of the extractable organic fraction of soils by using organic solvents, which is more representative of the actual contamination than only the 16 US EPA PAHs. Higher temperatures actually resulted in more pollutant degradation. Two treatments were about three times more effective than the others: soil heating to 60 °C during persulfate oxidation and soil preheating to 90 °C followed by permanganate oxidation. The results of this study showed that persulfate effectiveness was largely due to its thermal activation, whereas permanganate was more sensitive to PAH availability than persulfate. The technical feasibility of these two treatments will soon be field-tested in the unsaturated zone of one of the studied aged PAH-contaminated soils.

  14. 2017 Update on the WFC3/UVIS Stability and Contamination Monitor

    Science.gov (United States)

    Shanahan, C. E.; Gosmeyer, C. M.; Baggett, S.

    2017-06-01

    The photometric throughput of the UVIS detector on WFC3 is monitored each cycle for its stability as a function of time, wavelength, as well as to check for any evidence of contamination on the CCD windows, which would manifest as a decrease in throughput strongest in the bluest filters. This program has been in place since the installation of WFC3 in 2009, historically making periodic observations of the spectrophotometric standard GRW+70d5824 (GRW70) in several key filters from 200 nm to 600 nm, with red filters acting as a control. This is a follow up report to the last analysis of the temporal stability of UVIS (Gosmeyer et al., 2014), since which several major changes to the program and data analysis have been implemented. Due to recent work suggesting a low-level, long-term variability for GRW70, another spectrophotometric standard star - GD153 - has been added to the program and is now analyzed in conjunction with GRW70. Data are now processed with the latest version of the CALWF3 calibration pipeline (v. 3.4), which has several new features that represent a paradigm shift in calibration methodology. Finally, the data analysis software, which was previously entirely IRAF based, was re-written in Python. We find a steady decline in the count rate for most filters but no evidence for contamination, which would manifest as a wavelength-dependent effect, impacting bluer filters more strongly. These declines range from 0.01% to 0.3% per year, and are stronger in longer wavelength filters. Similar temporal changes are found for both stars, and the long-term trends in throughput agree with previous trends derived in 2014.

  15. Comparison of surface contamination monitors for in vivo measurement of {sup 131}I in thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M., E-mail: salomao.marques@ymail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The routine handling of radiopharmaceuticals in nuclear medicine represents a significant risk of internal exposure to the staff. The IAEA recommends the implementation of monitoring plans for all workers subject to a risk of exposures above 1 mSv per year. However, in Brazil, such recommendation is practically unfeasible due to the lack of a sufficient number of qualified internal dosimetry services over the country. This work presents an alternative based on a simple and inexpensive methodology aimed to perform in-vivo monitoring of {sup 131}I in thyroid using portable surface contamination probes. All models evaluated showed suitable sensitivity for such application. (author)

  16. Optimization of internal contamination monitoring programmes by studying uncertainties linked to dosimetric assessment

    International Nuclear Information System (INIS)

    Davesne, Estelle

    2010-01-01

    To optimise the protection of workers against ionizing radiations, the International Commission on Radiological Protection recommends the use of dose constraint and limits. To verify the compliance of the means of protection with these values when a risk of internal contamination exists, monitoring programmes formed of periodic bioassay measurements are performed. However, uncertainty in the dose evaluation arises from the variability of the activity measurement and from the incomplete knowledge of the exposure conditions. This uncertainty was taken into account by means of classical, Bayesian and possibilist statistics. The developed methodology was applied to the evaluation of the potential exposure during nuclear fuel preparation or mining; and to the analysis of the monitoring programme of workers purifying plutonium in AREVA NC La Hague reprocessing plant. From the measurement decision threshold, the minimum dose detectable (MDD) by the programme with a given confidence level can be calculated through the software OPSCI. It is shown to be a useful support in the optimisation of monitoring programmes when seeking a compromise between their sensitivity and their costs. (author)

  17. Combining Geoelectrical Measurements and CO 2 Analyses to Monitor the Enhanced Bioremediation of Hydrocarbon-Contaminated Soils: A Field Implementation

    OpenAIRE

    Noel , Cécile; Gourry , Jean-Christophe; Deparis , Jacques; Blessing , Michaela; Ignatiadis , Ioannis; Guimbaud , Christophe

    2016-01-01

    International audience; Hydrocarbon-contaminated aquifers can be successfully remediated through enhanced biodegradation. However, in situ monitoring of the treatment by piezometers is expensive and invasive and might be insufficient as the information provided is restricted to vertical profiles at discrete locations. An alternative method was tested in order to improve the robustness of the monitoring. Geophysical methods, electrical resistivity (ER) and induced polarization (IP), were combi...

  18. Effects of predicted climatic changes on distribution of organic contaminants in brackish water mesocosms

    Energy Technology Data Exchange (ETDEWEB)

    Ripszam, M., E-mail: matyas.ripszam@chem.umu.se [Department of Chemistry, Umea University, 901 87 Umeå (Sweden); Gallampois, C.M.J. [Department of Chemistry, Umea University, 901 87 Umeå (Sweden); Berglund, Å. [Department of Ecology and Environmental Sciences, Umeå University, 901 87 Umeå (Sweden); Larsson, H. [Umeå Marine Sciences Centre, Umeå University, Norrbyn, 905 71 Hörnefors (Sweden); Andersson, A. [Department of Ecology and Environmental Sciences, Umeå University, 901 87 Umeå (Sweden); Tysklind, M.; Haglund, P. [Department of Chemistry, Umea University, 901 87 Umeå (Sweden)

    2015-06-01

    Predicted consequences of future climate change in the northern Baltic Sea include increases in sea surface temperatures and terrestrial dissolved organic carbon (DOC) runoff. These changes are expected to alter environmental distribution of anthropogenic organic contaminants (OCs). To assess likely shifts in their distributions, outdoor mesocosms were employed to mimic pelagic ecosystems at two temperatures and two DOC concentrations, current: 15 °C and 4 mg DOC L{sup −1} and, within ranges of predicted increases, 18 °C and 6 mg DOC L{sup −1}, respectively. Selected organic contaminants were added to the mesocosms to monitor changes in their distribution induced by the treatments. OC partitioning to particulate matter and sedimentation were enhanced at the higher DOC concentration, at both temperatures, while higher losses and lower partitioning of OCs to DOC were observed at the higher temperature. No combined effects of higher temperature and DOC on partitioning were observed, possibly because of the balancing nature of these processes. Therefore, changes in OCs' fates may largely depend on whether they are most sensitive to temperature or DOC concentration rises. Bromoanilines, phenanthrene, biphenyl and naphthalene were sensitive to the rise in DOC concentration, whereas organophosphates, chlorobenzenes (PCBz) and polychlorinated biphenyls (PCBs) were more sensitive to temperature. Mitotane and diflufenican were sensitive to both temperature and DOC concentration rises individually, but not in combination. - Highlights: • More contaminants remained in the ecosystem at higher organic carbon levels. • More contaminants were lost in the higher temperature treatments. • The combined effects are competitive with respect to contaminant cycling. • The individual properties of each contaminant determine their respective fate.

  19. Effects of predicted climatic changes on distribution of organic contaminants in brackish water mesocosms

    International Nuclear Information System (INIS)

    Ripszam, M.; Gallampois, C.M.J.; Berglund, Å.; Larsson, H.; Andersson, A.; Tysklind, M.; Haglund, P.

    2015-01-01

    Predicted consequences of future climate change in the northern Baltic Sea include increases in sea surface temperatures and terrestrial dissolved organic carbon (DOC) runoff. These changes are expected to alter environmental distribution of anthropogenic organic contaminants (OCs). To assess likely shifts in their distributions, outdoor mesocosms were employed to mimic pelagic ecosystems at two temperatures and two DOC concentrations, current: 15 °C and 4 mg DOC L −1 and, within ranges of predicted increases, 18 °C and 6 mg DOC L −1 , respectively. Selected organic contaminants were added to the mesocosms to monitor changes in their distribution induced by the treatments. OC partitioning to particulate matter and sedimentation were enhanced at the higher DOC concentration, at both temperatures, while higher losses and lower partitioning of OCs to DOC were observed at the higher temperature. No combined effects of higher temperature and DOC on partitioning were observed, possibly because of the balancing nature of these processes. Therefore, changes in OCs' fates may largely depend on whether they are most sensitive to temperature or DOC concentration rises. Bromoanilines, phenanthrene, biphenyl and naphthalene were sensitive to the rise in DOC concentration, whereas organophosphates, chlorobenzenes (PCBz) and polychlorinated biphenyls (PCBs) were more sensitive to temperature. Mitotane and diflufenican were sensitive to both temperature and DOC concentration rises individually, but not in combination. - Highlights: • More contaminants remained in the ecosystem at higher organic carbon levels. • More contaminants were lost in the higher temperature treatments. • The combined effects are competitive with respect to contaminant cycling. • The individual properties of each contaminant determine their respective fate

  20. Innovative Methods for Integrating Knowledge for Long-Term Monitoring of Contaminated Groundwater Sites: Understanding Microorganism Communities and their Associated Hydrochemical Environment

    Science.gov (United States)

    Mouser, P. J.; Rizzo, D. M.; Druschel, G.; O'Grady, P.; Stevens, L.

    2005-12-01

    This interdisciplinary study integrates hydrochemical and genome-based data to estimate the redox processes occurring at long-term monitoring sites. Groundwater samples have been collected from a well-characterized landfill-leachate contaminated aquifer in northeastern New York. Primers from the 16S rDNA gene were used to amplify Bacteria and Archaea in groundwater taken from monitoring wells located in clean, fringe, and contaminated locations within the aquifer. PCR-amplified rDNA were digested with restriction enzymes to evaluate terminal restriction fragment length polymorphism (T-RFLP) community profiles. The rDNA was cloned, sequenced, and partial sequences were matched against known organisms using the NCBI Blast database. Phylogenetic trees and bootstrapping were used to identify classifications of organisms and compare the communities from clean, fringe, and contaminated locations. We used Artificial Neural Network (ANN) models to incorporate microbial data with hydrochemical information for improving our understanding of subsurface processes.

  1. Demolition and removal of radioactively contaminated concrete soil: Aerosol control and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Newton, G.J.; Hoover, M.D.; Grace, A.C. III

    1995-12-01

    From 1963 to 1985, two concrete-lined ponds were used to reduce the volume of radioactive liquids from the Institute`s research programs. Following withdrawal of the {open_quotes}hot ponds{close_quotes} from active use, the residual sludges and plastic liners of the ponds were removed and shipped to a radioactive waste disposal site. From 1987 to 1994, the concrete structures remained undisturbed pending environmental restoration on the site. Restoration began in 1994 and was completed in 1995. Restoration involved mechanical breakup and removal of the concrete structures and removal of areas of contaminated soils from the site. This report describes the design and results of the aerosol control and monitoring program that was conducted to ensure protection of workers and the environment during the restoration process. The aerosol control and monitoring strategy developed for remediation of the ITRI hot ponds was successful both in preventing dispersion of radioactive dusts and in demonstrating that exposures of workers and offsite releases were within statutory limits.

  2. Monitoring priority substances, other organic contaminants and heavy metals in a volcanic aquifer from different sources and hydrological processes.

    Science.gov (United States)

    Estevez, Esmeralda; Cabrera, María del Carmen; Fernández-Vera, Juan Ramón; Molina-Díaz, Antonio; Robles-Molina, José; Palacios-Díaz, María del Pino

    2016-05-01

    Irrigation with reclaimed water (R) is necessary to guarantee the sustainability of semi-arid areas. Results obtained during a two years monitoring network (2009-2011) in Gran Canaria are presented, including the analysis of chemical parameters, N and S isotopes, priority substances (2008/105/EC, 2013/39/EU), other organic contaminants and heavy metals in groundwater and R used to irrigate a golf course. The aims of this work are to evaluate the contamination in a volcanic aquifer, relate the presence of organic contaminants and heavy metals with the hydrogeochemistry and identify pollution sources in the area. No priority substance exceeded the EU thresholds for surface water, although seventeen were detected in R. The most frequent compounds were hexachlorobenzene, chlorpyrifos ethyl, fluorene, phenanthrene and pyrene. These compounds were detected at low concentration, except chlorpyrifos. Chlorpyrifos ethyl, terbuthylazine, diuron, terbutryn, procymidone, atrazine and propazine exceeded the European threshold concentration for pesticides in groundwater (100ngL(-1)). Therefore, the priority substances chlorpyrifos ethyl and diuron must be included in monitoring studies. The priority pesticides chlorfenvinphos and diazinon were always detected in R but rarely in groundwater. Besides, the existence of contaminants not related to the current R irrigation has been identified. Absence of environmental problems related to heavy metals can be expected. The relationship among contaminant presence, hydrogeochemistry, including the stable isotopic prints of δ(18)O, δ(15)N and δ(34)S and preferential recharge paths has been described. The coastal well shows high values of EC, nitrate, a variable chemistry, and 50% of organic contaminants detected above 100ngL(-1). The well located in the recharge area presents a stable hydrochemistry, the lowest value of δ(15)N and the lowest contaminants occurrence. The area is an example of a complex volcanic media with several

  3. Device for contamination monitoring against radiation contamination of people

    International Nuclear Information System (INIS)

    Rische, U.W.; Gerlach, R.

    1986-01-01

    The monitor has only two detector columns at an angle to one another and possibly divided in height, whose detectors are divided in the vertical direction in a middle range depending on a reference shape. The units formed by the subdivision equal the effect produced by the subdivision in approximation to the reference shape in evaluation. By including the detector columns divided into several detectors in height, a detector of about half the width is produced at a level above the threshold. Underarm boxes are provided at the outer edge of this detector, which are directed obliquely upwards. (orig./HP) [de

  4. Compliance Groundwater Monitoring of Nonpoint Sources - Emerging Approaches

    Science.gov (United States)

    Harter, T.

    2008-12-01

    Groundwater monitoring networks are typically designed for regulatory compliance of discharges from industrial sites. There, the quality of first encountered (shallow-most) groundwater is of key importance. Network design criteria have been developed for purposes of determining whether an actual or potential, permitted or incidental waste discharge has had or will have a degrading effect on groundwater quality. The fundamental underlying paradigm is that such discharge (if it occurs) will form a distinct contamination plume. Networks that guide (post-contamination) mitigation efforts are designed to capture the shape and dynamics of existing, finite-scale plumes. In general, these networks extend over areas less than one to ten hectare. In recent years, regulatory programs such as the EU Nitrate Directive and the U.S. Clean Water Act have forced regulatory agencies to also control groundwater contamination from non-incidental, recharging, non-point sources, particularly agricultural sources (fertilizer, pesticides, animal waste application, biosolids application). Sources and contamination from these sources can stretch over several tens, hundreds, or even thousands of square kilometers with no distinct plumes. A key question in implementing monitoring programs at the local, regional, and national level is, whether groundwater monitoring can be effectively used as a landowner compliance tool, as is currently done at point-source sites. We compare the efficiency of such traditional site-specific compliance networks in nonpoint source regulation with various designs of regional nonpoint source monitoring networks that could be used for compliance monitoring. We discuss advantages and disadvantages of the site vs. regional monitoring approaches with respect to effectively protecting groundwater resources impacted by nonpoint sources: Site-networks provide a tool to enforce compliance by an individual landowner. But the nonpoint source character of the contamination

  5. Response of monitors of surface contamination to internal exposition control from {sup 131}I in the 'nuclear medicine services'; Respuesta de monitores de contaminacion superficial para el control de la exposicion interna a {sup 131}I en servicios de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Puerta, Nancy; Rojo, Ana M.; Villella, Adrian; Gossio, Sebastian; Parada, Ines Gomez, E-mail: info@arn.gov.br [Autoridad Regulatoria Nuclear (ARN), Buenos Aires (Argentina); Acosta, Norma; Arenas, German, E-mail: nacosta@fuesmen.edu.ar [Fundacion Escuela de Medina Nuclear (FUESMEN), Mendoza (Argentina)

    2013-11-01

    The IAEA, in its publication RS-G-1.2, proposes individual control of workers occupationally exposed with risk of internal exposure when the potential exposure provided by incorporation leads to a value of annual committed effective dose equal to or greater than 1 mSv. Because the radionuclide {sup 131}I is the most important to control internal exposure in Nuclear Medicine Services, it is evaluated if the surface contamination monitors, commonly used in nuclear medicine centers of Argentina, would implement individual control of internal exposure to {sup 131}I. Selected detectors were calibrated with a dummy neck and thyroid with calibrated sources of {sup 131}I and {sup 133}Ba reference. For each detector is was estimated the detection efficiency for {sup 131}I and its detection limit. Each instrument was evaluated for the lowest effective dose possible to detect compromised by individual routine monitoring with different measurement intervals . We analyzed the response of each team for determining conditions that may be effective for the control of internal exposure of {sup 131}I. Finally , we conclude that the daily individual monitoring surface contamination detectors available in the Nuclear Medicine Services is feasible to implement and ensures detection of significant additions of {sup 131}I.

  6. Alpha contamination assessment for D ampersand D activities: Monitoring inside glove boxes and vessels

    International Nuclear Information System (INIS)

    Rawool-Sullivan, M.W.; Bolton, R.D.; Conaway, J.G.; MacArthur, D.W.

    1996-02-01

    We have developed a new approach to glove box monitoring that involves drawing air out of one glove port through a detection grid that collects ions created in the air inside the glove box by ionizing radiation, especially alpha radiation. The charge deposited on the detection grid by the ions is measured with a sensitive electrometer. The air can be circulated back to the glove box through the other glove port, preventing contamination from leaving the glove box and detector system. Initial experiments using a mock-up constructed of sheet metal indicate that this technology provides the measurement technique needed to perform a defensible, non-invasive measurement of alpha contamination inside glove boxes destined for waste disposal. This can result in an enormous cost savings if a given glove box can be shown to fall into the catagory of Low-Level Waste rather than Trans-Uranic Waste. Considering that hundreds of glove boxes contaminated with plutonium will be taken out of service at various nuclear facilities over the next few years, the potential cost savings associated with disposal as LLW rather than TRU waste are substantial

  7. Evaluation of decontamination during dismantling of plutonium-contaminated glove boxes

    International Nuclear Information System (INIS)

    Kinugasa, Manabu; Taguchi, Seigi; Ohzeki, Satoru; Inoue, Yoshiaki; Kashima, Sadamitsu

    1981-01-01

    The dismantling work of plutonium-contaminated glove boxes was carried out. These glove boxes had been used for the R and D of plutonium-uranium mixed oxide fuel for 15 years. The work was carried out in a pressure-controlled greenhouse, and the contamination of air in the greenhouse was monitored continuously. In order to reduce the contamination of air during dismantling, the decontamination and fixation of loose contaminants on the surfaces of glove boxes were very important. The correlation between decontamination and the contamination of air regarding dismantling is reported in this paper. The surface contamination density of the glove boxes was measured utilizing the smear method before and after the decontamination, and the decontamination effects were estimated. The contamination of air during dismantling was continuously measured with a plutonium dust monitor. It was found that loose contamination exponentially decreased by the decontamination process. When the so-called wet glove boxes, which contained wet recovery and waste disposal apparatus, were dismantled, the contamination of air did not exceed 500 (MPC) a. However, the contamination of air exceeded 500 (MPC) a several times in the present work of dismantling the so-called dry glove boxes which had been used for the fabrication of plutonium-uranium mixed oxide pellets. (Kato, T.)

  8. Development of custom LCD based portable survey/contamination monitors

    International Nuclear Information System (INIS)

    Reddy, J.D.

    2010-01-01

    Equipments for carrying out radiation survey measurements for alpha, beta and gamma radiations have evolved considerably with the advancements in Electronics overtime. There are 2 major classes of portable instruments available from most manufacturers - (a) Analog indicator type (b) Direct digital readout type. Analog meters give a direct quantifying feel to radiation levels though they are not rich features nor they have smartness like a digital meter. Digital versions have advantages of direct readout numerically and configurable as per users requirements. To achieve best features of both the techniques a dual indicator type LCD module comprising of Analog indicating LCD segments and digital readout indicating 7 segments has been developed. This LCD comprising of LCD glass and its display driver has been deployed across various types of survey meters and contamination monitors manufactured by Nucleonix. This display now facilitates direct readout of dose rate/count rate in various units simultaneously in both analog LCD scale and direct digital indication. (author)

  9. Vadose zone studies at an industrial contaminated site: the vadose zone monitoring system and cross-hole geophysics

    Science.gov (United States)

    Fernandez de Vera, Natalia; Beaujean, Jean; Jamin, Pierre; Nguyen, Frédéric; Dahan, Ofer; Vanclooster, Marnik; Brouyère, Serge

    2014-05-01

    In order to improve risk characterization and remediation measures for soil and groundwater contamination, there is a need to improve in situ vadose zone characterization. However, most available technologies have been developed in the context of agricultural soils. Such methodologies are not applicable at industrial sites, where soils and contamination differ in origin and composition. In addition, most technologies are applicable only in the first meters of soils, leaving deeper vadose zones with lack of information, in particular on field scale heterogeneity. In order to overcome such difficulties, a vadose zone experiment has been setup at a former industrial site in Belgium. Industrial activities carried out on site left a legacy of soil and groundwater contamination in BTEX, PAH, cyanide and heavy metals. The experiment comprises the combination of two techniques: the Vadose Zone Monitoring System (VMS) and cross-hole geophysics. The VMS allows continuous measurements of water content and temperature at different depths of the vadose zone. In addition, it provides the possibility of pore water sampling at different depths. The system is formed by a flexible sleeve containing monitoring units along its depth which is installed in a slanted borehole. The flexible sleeve contains three types of monitoring units in the vadose zone: Time Domain Transmissometry (TDT), which allows water content measurements; Vadose Sampling Ports (VSP), used for collecting water samples coming from the matrix; the Fracture Samplers (FS), which are used for retrieving water samples from the fractures. Cross-hole geophysics techniques consist in the injection of an electrical current using electrodes installed in vertical boreholes. From measured potential differences, detailed spatial patterns about electrical properties of the subsurface can be inferred. Such spatial patterns are related with subsurface heterogeneities, water content and solute concentrations. Two VMS were

  10. Use of dual-head gamma camera in radionuclide internal contamination monitoring on radiation workers from a nuclear medicine department

    International Nuclear Information System (INIS)

    Rodriguez-Laguna, A.; Brandan, M.E.

    2008-01-01

    As a part of an internal dosimetry program that is performed at the Mexican National Institute of Cancerology - Nuclear Medicine Department, in the present work we suggest a procedure for the routinely monitoring of internal contamination on radiation workers and nuclear medicine staff. The procedure is based on the identification and quantification of contaminating radionuclides in human body by using a dual-head whole-body gamma camera. The results have shown that the procedures described in this study can be used to implement a method to quantify minimal accumulated activity in the main human organs to evaluate internal contamination with radionuclides. The high sensitivity of the uncollimated gamma camera is advantageous for the routinely detection and identification of small activities of internal contamination. But, the null spatial resolution makes impossible the definition of contaminated region of interest. Then, the use of collimators is necessary to the quantification of incorporated radionuclides activities in the main human organs and for the internal doses assessment. (author)

  11. Optimization of the control of contamination at nuclear power plants

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.

    1988-05-01

    A methodology is described for the optimization of the actions taken to control contamination. It deals with many aspects of contamination, such as the monetary value assigned to a unit of radiation dose, the treatment of skin and extremity dose, and the inefficiencies introduced from working in a contaminated environemnt. The optimization method is illustrated with two case studies based on cleanup projects at nuclear power plants. Guidelines for the use of protective apparel, and for monitoring radiation and contamination at various levels of contamination are presented. The report concludes that additional research is required to quantify the effect of a contaminated environment on work efficiencies

  12. Contamination control plan for prelaunch operations

    Science.gov (United States)

    Austin, J. D.

    1983-01-01

    A unified, systematic plan is presented for contamination control for space flight systems. Allowable contaminant quantities, or contamination budgets, are determined based on system performance margins and system-level allowable degradations. These contamination budgets are compared to contamination rates in ground environments to establish the controls required in each ground environment. The use of feedback from contamination monitoring and some contamination control procedures are discussed.

  13. Workplace monitoring for radiation and contamination

    International Nuclear Information System (INIS)

    1995-01-01

    Ionizing radiations cannot be seen, felt or sensed by the human body in any way but excessive exposure to them may have adverse health effects. In order to avoid excessive exposure, appropriate and efficient radiation measuring instruments are needed. This Module explains the basic terminology associated with such measuring instruments and describes the principal types, their construction and typical applications in the workplace. It is important to ensure not only that monitoring is carried out where there is a potential radiation exposure but also that the monitoring instrument is appropriate to the task and that the user places correct interpretations on the results obtained. The Manual will be of most benefit if it forms part of more comprehensive training or is supplemented by the advice of a qualified expert in radiation protection. Some of the instrument tests and calibrations described in this Module require the services of a qualified expert

  14. The last generation of contamination and exposure rate meters and monitors designed in Boris Kidric Institute

    International Nuclear Information System (INIS)

    Koturovic, A.M.; Sobajic, M.V.; Smelcerovic, M.A.; Damljanovic, D.D.; Drndarevic, V.R.

    1989-01-01

    The last generation of contamination and exposure rate meters and monitors designed and produced in Boris Kidric Institute, presented in this paper, are digital survey instruments. The common principle of these instruments is the 'simple precision' concept, i.e. predetermined time pulse counting. This principle is discussed and basic structure of these instruments is shown with their possibilities and features (author)

  15. Status of contamination monitoring in radiation activities of National Atomic Energy Agency (NAEA) in Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Suhariyono, Gatot [National Atomic Energy Agency, Jakarta (Indonesia)

    1997-06-01

    National Atomic Energy Agency (NAEA) or Badan Tenaga Atom Nasional (BATAN) is a non departmental governmental agency, headed by a Director General who is directly responsible to the President. Center for Standardization and Radiation Safety Research (CSRSR) is one of the research centers within the deputy for the assessment of nuclear science and technology of the NAEA. The main task of the CSRSR is to implement research and development program, development and services in the field of radiation safety, standardization, dosimetry, radiation health as well as the application of nuclear techniques in medicine, according to the policy confirmed by the director general of BATAN. Task of radiation protection division is to set up programs and to develop radiation protection, personal monitoring system and radiation level of the working areas and their surroundings as well as dose limitation system, to carry out technical up grading of radiation protection officials skill and to help coping with radiation accident. The key factor on contamination monitoring is to reduce human error and mechanical failures. These problems can be achieved to the highest degree by developing knowledge and skill of staffs via trainings or courses on contamination and decontamination, so that they are hoped to become trained and qualified staffs. (G.K.)

  16. Monitoring of metallic contaminants in energy drinks using ICP-MS.

    Science.gov (United States)

    Kilic, Serpil; Cengiz, Mehmet Fatih; Kilic, Murat

    2018-03-09

    In this study, an improved method was validated for the determination of some metallic contaminants (arsenic (As), chromium (Cr), cadmium (Cd), lead (Pb), iron (Fe), nickel (Ni), copper (Cu), Mn, and antimony (Sb)) in energy drinks using inductive coupled plasma mass spectrometry (ICP-MS). The validation procedure was applied for the evaluation of linearity, repeatability, recovery, limit of detection, and quantification. In addition, to verify the trueness of the method, it was participated in an interlaboratory proficiency test for heavy metals in soft drink organized by the LGC (Laboratory of the Government Chemist) Standard. Validated method was used to monitor for the determination of metallic contaminants in commercial energy drink samples. Concentrations of As, Cr, Cd, Pb, Fe, Ni, Cu, Mn, and Sb in the samples were found in the ranges of 0.76-6.73, 13.25-100.96, 0.16-2.11, 9.33-28.96, 334.77-937.12, 35.98-303.97, 23.67-60.48, 5.45-489.93, and 0.01-0.42 μg L -1 , respectively. The results were compared with the provisional guideline or parametric values of the elements for drinking waters set by the WHO (World Health Organization) and EC (European Commission). As, Cd, Cu, and Sb did not exceed the WHO and EC provisional guideline or parametric values. However, the other elements (Cr, Pb, Fe, Ni, and Mn) were found to be higher than their relevant limits at various levels.

  17. Restoration of contaminated ecosystems: adaptive management in a changing climate

    Science.gov (United States)

    Farag, Aida; Larson, Diane L.; Stauber, Jenny; Stahl, Ralph; Isanhart, John; McAbee, Kevin T.; Walsh, Christopher J.

    2017-01-01

    Three case studies illustrate how adaptive management (AM) has been used in ecological restorations that involve contaminants. Contaminants addressed include mercury, selenium, and contaminants and physical disturbances delivered to streams by urban stormwater runoff. All three cases emphasize the importance of broad stakeholder input early and consistently throughout decision analysis for AM. Risk of contaminant exposure provided input to the decision analyses (e.g. selenium exposure to endangered razorback suckers, Stewart Lake; multiple contaminants in urban stormwater runoff, Melbourne) and was balanced with the protection of resources critical for a desired future state (e.g. preservation old growth trees, South River). Monitoring also played a critical role in the ability to conduct the decision analyses necessary for AM plans. For example, newer technologies in the Melbourne case provided a testable situation where contaminant concentrations and flow disturbance were reduced to support a return to good ecological condition. In at least one case (Stewart Lake), long-term monitoring data are being used to document the potential effects of climate change on a restoration trajectory. Decision analysis formalized the process by which stakeholders arrived at the priorities for the sites, which together constituted the desired future condition towards which each restoration is aimed. Alternative models were developed that described in mechanistic terms how restoration can influence the system towards the desired future condition. Including known and anticipated effects of future climate scenarios in these models will make them robust to the long-term exposure and effects of contaminants in restored ecosystems.

  18. Multi-controller based 29 channel whole body portal monitor

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Portal Monitors are an essential part of personnel monitoring programme in any Nuclear Power Plant or Radiochemical/Reprocessing Plant. Compared to conventional Portal Monitors, whole-body Portals are preferred, for effective monitoring of entire body of the person being monitored for radioactive contamination. This is achieved by effectively distributing a large number of detectors on front/back of the person being monitored. The entry and exit for such Portals is usually side ways. The electronic system, designed essentially consists of powerful compact electronic circuits, comprising of three micro-controllers, a host of (32) 12C serial counters, other serial ADCs, DACs etc., apart from pulse processing, HV and LV circuits. Built-in embedded code has powerful fault diagnostics routines to show up failures in detector / detector electronics, HV, LV and other circuits apart from indicating contamination status, through visual and aural indications such as MIMIC, visual LCD display and individual channel counts etc. The Portal structural design consists of four individual SS members integrated, lead shielding assemblies (inside), on hinged support frames facilitate ease of assembling and dismantling of the structure. The detector arrangement is so arranged to have optimal uniform spread out, so as to record contamination of the whole body of the person being monitored. (author)

  19. The Effect of Stellar Contamination on Transmission Spectra of Low-mass Exoplanets

    Science.gov (United States)

    Rackham, Benjamin V.; Apai, Daniel; Giampapa, Mark S.

    2017-10-01

    Transmission spectroscopy offers the exciting possibility of studying terrestrial exoplanet atmospheres in the near-term future. The Transiting Exoplanet Survey Satellite (TESS), scheduled for launch next year, is expected to discover thousands of transiting exoplanets around bright host stars, including an estimated twenty habitable zone super-Earths. The brightness of the TESS host stars, combined with refined observational strategies and near-future facilities, will enable searches for atmospheric signatures from smaller and cooler exoplanets. These observations, however, will be increasingly subject to noise introduced by heterogeneities in the host star photospheres, such as star spots and faculae. In short, the transmission spectroscopy method relies on the assumption that the spectrum of the transit chord does not differ from that of the integrated stellar disk or, if it does, the contribution of photospheric heterogeneities to the transmission spectrum can be constrained by variability monitoring. However, any axisymmetric populations of spots and faculae will strongly affect transmission spectra, and their presence cannot be deduced from monitoring efforts. A clear need exists for a more robust understanding of stellar contamination on transmission spectra. Here we summarize our work on the impact of heterogeneous stellar photospheres on transmission spectra and detail implications for atmospheric characterization efforts. By modeling spot and faculae distributions in stellar photospheres, we find that spot-covering fractions extrapolated from observed variability amplitudes are significantly underestimated. Likewise, corrections based on variability monitoring likely fall short of the actual stellar spectral contamination. We provide examples of contamination spectra for typical levels of stellar activity across a range of spectral types. For M dwarfs, molecular absorption features in spots and faculae can imprint apparent features in transmission spectra

  20. A potential approach for monitoring drinking water quality from groundwater systems using organic matter fluorescence as an early warning for contamination events.

    Science.gov (United States)

    Stedmon, Colin A; Seredyńska-Sobecka, Bożena; Boe-Hansen, Rasmus; Le Tallec, Nicolas; Waul, Christopher K; Arvin, Erik

    2011-11-15

    The fluorescence characteristics of natural organic matter in a groundwater based drinking water supply plant were studied with the aim of applying it as a technique to identify contamination of the water supply. Excitation-emission matrices were measured and modeled using parallel factor analysis (PARAFAC) and used to identify which wavelengths provide the optimal signal for monitoring contamination events. The fluorescence was characterized by four components: three humic-like and one amino acid-like. The results revealed that the relative amounts of two of the humic-like components were very stable within the supply plant and distribution net and changed in a predictable fashion depending on which wells were supplying the water. A third humic-like component and an amino acid-like component did not differ between wells. Laboratory contamination experiments with wastewater revealed that combined they could be used as an indicator of microbial contamination. Their fluorescence spectra did not overlap with the other components and therefore the raw broadband fluorescence at the wavelengths specific to their fluorescence could be used to detect contamination. Contamination could be detected at levels equivalent to the addition of 60 μg C/L in drinking water with a TOC concentration of 3.3 mg C/L. The results of this study suggest that these types of drinking water systems, which are vulnerable to microbial contamination due to the lack of disinfectant treatment, can be easily monitored using online organic matter fluorescence as an early warning system to prompt further intensive sampling and appropriate corrective measures. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Monitoring of Radionuclide Contamination in Food Samples in Malaysia due to Daiichi Reactor Accident in Fukushima, Japan

    International Nuclear Information System (INIS)

    Nurrul Assyikeen Mohd Jaffary; Abdul Kadir Ishak; Wo, Y.M.

    2011-01-01

    On March 11, 2011, a serious accident occurred in Daiichi nuclear reactor plant, Fukushima, Japan which caused radioactive materials been released into the atmosphere in the form of aerosols and dust particles. Sea water around the plant was also found contaminated with high radioactivity readings. These radioactive materials could be transported by the winds and ocean current across international borders and cannot be controlled by human. Besides a continuous monitoring activity of radionuclide content in the air and sea water that need to be conducted by the authorities, Malaysia should also control the entry of radionuclide through contaminated food ingestion by human. Radionuclide I-131, Cs-134 and Cs-137 were used as a counter-measure of pollution levels and counted with gamma spectrometry using standard analysis method suggested by AOAC International. In this paper, details description of the role of Radiochemical and Environment Group, Nuclear Malaysia who's responsible in analyzing the radioactivity in the food samples due to Fukushima Daiichi, Japan accident was included. Also discussed are the radioactivity limit adopted and analysis results from this monitoring. (author)

  2. Drought-induced effects on contaminant distribution

    International Nuclear Information System (INIS)

    Makdisi, R.S.

    1991-01-01

    The drought in California has caused significant redistribution of contaminants, particularly petroleum hydrocarbon and VOCs, at known hazardous waste sites. Free-floating petroleum hydrocarbon on the water table has been particularly susceptible to redistribution because it is easily removed by soil sorption. Sorption of petroleum hydrocarbon and VOCs onto the soil can result in soil hydrocarbon concentrations above the regulatory action levels requiring soil remediation. This phenomenon necessitated a reevaluation of the existing remedial action plans, particularly with respect to groundwater extraction and treatment systems designed to extract free-floating product and/or dissolved hydrocarbon. In this paper, the application of modifying an existing remedial action plan is illustrated by a case study involving the Atwater Elementary School site in Atwater, California. In response to leakage of an estimated 7,000 gallons of gasoline from the underground fuel storage tank, a radial-arm extraction well with a fuel product/water separation system was installed to remove the floating product layer from the unconfined aquifer. Additional extraction wells were installed and seventeen monitoring wells were installed into three discrete aquifers to evaluate the extent of hydrocarbon-contaminated groundwater to be treated after removal of the product layer

  3. Bonding of radioactive contamination. IV. Effect of surface finish

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1983-01-01

    The mechanisms by which radioactive contamination would be bonded to a DWPF canister are being investigated. Previous investigations in this series have examined the effects of temperature, oxidation before contamination, and atmosphere composition control on the bonding of contamination. This memorandum describes the results of tests to determine the effect of special surface finishes on the bonding of contamination to waste glass canisters. Surface pretreatments which produce smoother canister surfaces actually cause radioactive contamination to be more tightly bonded to the metal surface than on an untreated surface. Based on the results of these tests it is recommended that the canister surface finish be specified as having a bright cold rolled mill finish equivalent to ASTM No. 2B. 7 references, 3 figures, 3 tables

  4. Monitored Natural Attenuation of ino9rganic Contaminants Treatability Study Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Crapse, K

    2004-05-19

    The identification and quantification of key natural attenuation processes for inorganic contaminants at D-Area is detailed herein. Two overarching goals of this evaluation of monitored natural attenuation (MNA) as a remediation strategy were (1) to better define the availability of inorganic contaminants as potential sources for transport to groundwater and uptake by environmental receptors and (2) to understand the site-specific mechanisms controlling attenuation of these inorganic contaminants through tandem geochemical and biological characterization. Data collected in this study provides input for more appropriate site groundwater transport models. Significant natural attenuation is occurring at D-Area as evidenced by relatively low aqueous concentrations of constituents of concern (COCs) (Be, Ni, U, and As) at all locations characterized and the decrease in groundwater concentrations with increasing distance from the source. The observed magnitude of decrease in groundwater concentrations of COCs with distance from the D-Area Coal Pile Runoff Basin (DCPRB) could not be accounted for by the modeled physical attenuation processes of dilution/dispersion. This additional attenuation, i.e., the observed difference between the groundwater concentrations of COCs and the modeled physical attenuation, is due to biogeochemical processes occurring at the D-Area. In tandem geochemical and microbiological characterization studies designed to evaluate the mechanisms contributing to natural attenuation, pH was the single parameter found to be most predictive of contaminant attenuation. The increasing pH with distance from the source is likely responsible for increased sorption of COCs to soil surfaces within the aquifer at D-Area. Importantly, because the sediments appear to have a high buffering capacity, the acid emanating from the DCPRB has been neutralized by the soil, and these conditions have led to large Kd values at the site. Two major types of soils are present at

  5. Monitoring of Soil Contamination by Heavy Metals in the Impact Zone of Copper-Nickel Smelter on the Kola Peninsula

    Science.gov (United States)

    Kashulina, G. M.

    2018-04-01

    The results of landscape monitoring of the concentrations of acid-extractable Ni, Cu, Co, Mn, and Zn in soils of the local impact zone of the Severonikel industrial complex on the Kola Peninsula are discussed. The aim of monitoring studies was to reveal the spatial and temporal regularities of variation in the degree of soil contamination by heavy metals. In 2001-2011, the concentrations of acid-extractable compounds of the elements in the upper part of organic soil horizons around this plant exceeded their background concentrations by two orders of magnitude for Cu and Co and by three orders of magnitude for Ni. The degree of topsoil contamination with Ni, Cu, and Co generally corresponded to the distance of the plots from the contamination source and to the modern technogenic load. However, because of the long period of the emissions, their extreme amounts, and complex composition, indirect factors—the degree of technogenic soil degradation, the loss of soil organic matter, saturation of the surface soil layers by the contaminating metals, and competitive relationships between the elements—also affect soil contamination level. The concentrations of all the studied metals in the topsoil are characterized by considerable (1.5 to 7 times) variability in their long-term dynamics. The most important factors of this variability for Ni, Cu, and Co are the organic matter content of the samples and the amount of atmospheric precipitation in the year preceding the sampling. An inverse relationship between element concentrations in the soils and the amount of atmospheric precipitation attests to the dynamic nature and reversible character of the accumulation of heavy metals in the soils.

  6. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    Directory of Open Access Journals (Sweden)

    Jennifer L. Banach

    2015-07-01

    Full Text Available The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water disinfectants during produce processing with the aim to prevent cross-contamination of pathogens. Process wash water disinfection requires short contact times so microorganisms are rapidly inactivated. Free chlorine, chlorine dioxide, ozone, and peracetic acid were considered suitable disinfectants. A disinfectant’s reactivity with the organic matter will determine the disinfectant residual, which is of paramount importance for microbial inactivation and should be monitored in situ. Furthermore, the chemical and worker safety, and the legislative framework will determine the suitability of a disinfection technique. Current research often focuses on produce decontamination and to a lesser extent on preventing cross-contamination. Further research on a sanitizer’s efficacy in the washing water is recommended at the laboratory scale, in particular with experimental designs reflecting industrial conditions. Validation on the industrial scale is warranted to better understand the overall effects of a sanitizer.

  7. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    Science.gov (United States)

    Banach, Jennifer L.; Sampers, Imca; Van Haute, Sam; van der Fels-Klerx, H.J. (Ine)

    2015-01-01

    The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water disinfectants during produce processing with the aim to prevent cross-contamination of pathogens. Process wash water disinfection requires short contact times so microorganisms are rapidly inactivated. Free chlorine, chlorine dioxide, ozone, and peracetic acid were considered suitable disinfectants. A disinfectant’s reactivity with the organic matter will determine the disinfectant residual, which is of paramount importance for microbial inactivation and should be monitored in situ. Furthermore, the chemical and worker safety, and the legislative framework will determine the suitability of a disinfection technique. Current research often focuses on produce decontamination and to a lesser extent on preventing cross-contamination. Further research on a sanitizer’s efficacy in the washing water is recommended at the laboratory scale, in particular with experimental designs reflecting industrial conditions. Validation on the industrial scale is warranted to better understand the overall effects of a sanitizer. PMID:26213953

  8. Soil magnetic susceptibility as indicator of radioactive contamination

    International Nuclear Information System (INIS)

    Curda, S.

    2006-01-01

    Measurement of magnetic susceptibility is a method, which is used in many areas of research. The locality Ak-Tjuz is typical example of old ecological load. One of the negative effects represents radioactive contamination. This situation is caused by environmental disaster in 1964. For useful reparation it is really necessary to determinate the surface range of contamination. And measurement of the magnetic susceptibility could be the suitable method for that kind of monitoring. (author)

  9. 1,4-Dioxane drinking water occurrence data from the third unregulated contaminant monitoring rule.

    Science.gov (United States)

    Adamson, David T; Piña, Elizabeth A; Cartwright, Abigail E; Rauch, Sharon R; Hunter Anderson, R; Mohr, Thomas; Connor, John A

    2017-10-15

    This study examined data collected from U.S. public drinking water supplies in support of the recently-completed third round of the Unregulated Contaminant Monitoring Rule (UCMR3) to better understand the nature and occurrence of 1,4-dioxane and the basis for establishing drinking water standards. The purpose was to evaluate whether the occurrence data for this emerging but federally-unregulated contaminant fit with common conceptual models, including its persistence and the importance of groundwater contamination for potential exposure. 1,4-Dioxane was detected in samples from 21% of 4864 PWSs, and was in exceedance of the health-based reference concentration (0.35μg/L) at 6.9% of these systems. In both measures, it ranked second among the 28 UCMR3 contaminants. Although much of the focus on 1,4-dioxane has been its role as a groundwater contaminant, the detection frequency for 1,4-dioxane in surface water was only marginally lower than in groundwater (by a factor of 1.25; pwater (pwater sources tend to be more dilute. Sampling from large systems increased the likelihood that 1,4-dioxane was detected by a factor of 2.18 times relative to small systems (pwater were highly associated with detections of other chlorinated compounds particularly 1,1-dichlorethane (odds ratio=47; pchlorinated solvent stabilizer. Based on aggregated nationwide data, 1,4-dioxane showed evidence of a decreasing trend in concentration and detection frequency over time. These data suggest that the loading to drinking water supplies may be decreasing. However, in the interim, some water supply systems may need to consider improving their treatment capabilities in response to further regulatory review of this compound. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Tools for monitoring aquatic environments to identify anthropic effects.

    Science.gov (United States)

    da Rocha, Monyque Palagano; Dourado, Priscila Leocadia Rosa; Cardoso, Claudia Andrea Lima; Cândido, Liliam Silva; Pereira, Joelson Gonçalves; de Oliveira, Kelly Mari Pires; Grisolia, Alexeia Barufatti

    2018-01-05

    Anthropic activities are directly related to the contamination of aquatic ecosystems owing to the release of numerous chemicals from agricultural and urban waste. These contaminants cause environmental degradation and a decrease in the availability of water quality. The objective of this search was to evaluate the efficiency of physicochemical, chemical, and microbiological tests; extraction of chlorophyll a; and genetic parameters to identify anthropic activities and weather condition effects on the stream water quality and the consequences of its use by the population. The physicochemical parameters were within the limits allowed by the Brazilian law. However, contamination by metals (Cd 0.510 mg L -1 , Co 0.405 mg L -1 , and Ni 0.316 mg L -1 ) has been found at various collection points to be more than the allowable values. The antibiotic oxytetracycline was detected in stream water in quantities of up to 89 μg L -1 . In relation to microbiological contamination, Escherichia coli and Pseudomonas spp. have been isolated. The averages of chlorophyll a were up to 0.15558 mg cm -2 . Genetic tools identified greater number of micronuclei and DNA damage in periods that showed lower rainfall rates and lower amounts of metals. The analysis used for monitoring was efficient to verify the interference that animal breeding and planting of different cultures have caused on that stream. Thus, the continued use of this water for drinking, irrigation of vegetables, and recreational activities makes the population susceptible to contamination by bacteria and creates conditions for the development of genetic alterations in the long run.

  11. 1997 Comprehensive TNX Area Annual Groundwater and Effectiveness Monitoring Report

    International Nuclear Information System (INIS)

    Chase, J.

    1998-04-01

    Shallow groundwater beneath the TNX Area at the Savannah River Site (SRS) has been contaminated with chlorinated volatile organic compounds (CVOCs) such as trichloroethylene (TCE) and carbon tetrachloride. In November 1994, an Interim Record of Decision (IROD) was agreed to and signed by the U. S. Department of Energy (DOE), the Environmental Protection Agency (EPA), and the South Carolina Department of Health ampersand Environmental Control (SCDHEC). The Interim Record of Decision requires the installation of a hybrid groundwater corrective action (HGCA) to stabilize the plume of groundwater contamination and remove CVOCs dissolved in the groundwater. The hybrid groundwater corrective action included a recovery well network, purge water management facility, air stripper, and an airlift recirculation well. The recirculation well was dropped pursuant to a test that indicated it to be ineffective at the TNX Area. Consequently, the groundwater corrective action was changed from a hybrid to a single action, pump-and-treat approach. The Interim Action (IA) T-1 air stripper system began operation on September 16, 1996. a comprehensive groundwater monitoring program was initiated to measure the effectiveness of the system. As of December 31, 1997, the system has treated 32 million gallons of contaminated groundwater removed 32 pounds of TCE. The recovery well network created a 'capture zone' that stabilized the plume of contaminated groundwater

  12. 1997 Comprehensive TNX Area Annual Groundwater and Effectiveness Monitoring Report

    Energy Technology Data Exchange (ETDEWEB)

    Chase, J.

    1998-04-01

    Shallow groundwater beneath the TNX Area at the Savannah River Site (SRS) has been contaminated with chlorinated volatile organic compounds (CVOCs) such as trichloroethylene (TCE) and carbon tetrachloride. In November 1994, an Interim Record of Decision (IROD) was agreed to and signed by the U. S. Department of Energy (DOE), the Environmental Protection Agency (EPA), and the South Carolina Department of Health {ampersand} Environmental Control (SCDHEC). The Interim Record of Decision requires the installation of a hybrid groundwater corrective action (HGCA) to stabilize the plume of groundwater contamination and remove CVOCs dissolved in the groundwater. The hybrid groundwater corrective action included a recovery well network, purge water management facility, air stripper, and an airlift recirculation well. The recirculation well was dropped pursuant to a test that indicated it to be ineffective at the TNX Area. Consequently, the groundwater corrective action was changed from a hybrid to a single action, pump-and-treat approach. The Interim Action (IA) T-1 air stripper system began operation on September 16, 1996. a comprehensive groundwater monitoring program was initiated to measure the effectiveness of the system. As of December 31, 1997, the system has treated 32 million gallons of contaminated groundwater removed 32 pounds of TCE. The recovery well network created a `capture zone` that stabilized the plume of contaminated groundwater.

  13. Remediating radium contaminated legacy sites: Advances made through machine learning in routine monitoring of “hot” particles

    Energy Technology Data Exchange (ETDEWEB)

    Varley, Adam, E-mail: a.l.varley@stir.ac.uk [Department of Biological and Environmental Sciences, University of Stirling, Stirling FK9 4LA (United Kingdom); Tyler, Andrew, E-mail: a.n.tyler@stir.ac.uk [Department of Biological and Environmental Sciences, University of Stirling, Stirling FK9 4LA (United Kingdom); Smith, Leslie, E-mail: l.s.smith@cs.stir.ac.uk [Department of Computing Science and Mathematics, University of Stirling, Stirling FK9 4LA (United Kingdom); Dale, Paul, E-mail: paul.dale@sepa.org.uk [Scottish Environmental Protection Agency, Radioactive Substances, Strathallan House, Castle Business Park, Stirling FK9 4TZ (United Kingdom); Davies, Mike, E-mail: Mike.Davies@nuvia.co.uk [Nuvia Limited, The Library, Eight Street, Harwell Oxford, Didcot, Oxfordshire OX11 0RL (United Kingdom)

    2015-07-15

    The extensive use of radium during the 20th century for industrial, military and pharmaceutical purposes has led to a large number of contaminated legacy sites across Europe and North America. Sites that pose a high risk to the general public can present expensive and long-term remediation projects. Often the most pragmatic remediation approach is through routine monitoring operating gamma-ray detectors to identify, in real-time, the signal from the most hazardous heterogeneous contamination (hot particles); thus facilitating their removal and safe disposal. However, current detection systems do not fully utilise all spectral information resulting in low detection rates and ultimately an increased risk to the human health. The aim of this study was to establish an optimised detector-algorithm combination. To achieve this, field data was collected using two handheld detectors (sodium iodide and lanthanum bromide) and a number of Monte Carlo simulated hot particles were randomly injected into the field data. This allowed for the detection rate of conventional deterministic (gross counts) and machine learning (neural networks and support vector machines) algorithms to be assessed. The results demonstrated that a Neural Network operated on a sodium iodide detector provided the best detection capability. Compared to deterministic approaches, this optimised detection system could detect a hot particle on average 10 cm deeper into the soil column or with half of the activity at the same depth. It was also found that noise presented by internal contamination restricted lanthanum bromide for this application. - Highlights: • Land contaminated with radium is hazardous to human health. • Routine monitoring permits identification and removal of radioactive hot particles. • Current alarm algorithms do not provide reliable hot particle detection. • Spectral processing using Machine Learning significantly improves detection.

  14. Remediating radium contaminated legacy sites: Advances made through machine learning in routine monitoring of “hot” particles

    International Nuclear Information System (INIS)

    Varley, Adam; Tyler, Andrew; Smith, Leslie; Dale, Paul; Davies, Mike

    2015-01-01

    The extensive use of radium during the 20th century for industrial, military and pharmaceutical purposes has led to a large number of contaminated legacy sites across Europe and North America. Sites that pose a high risk to the general public can present expensive and long-term remediation projects. Often the most pragmatic remediation approach is through routine monitoring operating gamma-ray detectors to identify, in real-time, the signal from the most hazardous heterogeneous contamination (hot particles); thus facilitating their removal and safe disposal. However, current detection systems do not fully utilise all spectral information resulting in low detection rates and ultimately an increased risk to the human health. The aim of this study was to establish an optimised detector-algorithm combination. To achieve this, field data was collected using two handheld detectors (sodium iodide and lanthanum bromide) and a number of Monte Carlo simulated hot particles were randomly injected into the field data. This allowed for the detection rate of conventional deterministic (gross counts) and machine learning (neural networks and support vector machines) algorithms to be assessed. The results demonstrated that a Neural Network operated on a sodium iodide detector provided the best detection capability. Compared to deterministic approaches, this optimised detection system could detect a hot particle on average 10 cm deeper into the soil column or with half of the activity at the same depth. It was also found that noise presented by internal contamination restricted lanthanum bromide for this application. - Highlights: • Land contaminated with radium is hazardous to human health. • Routine monitoring permits identification and removal of radioactive hot particles. • Current alarm algorithms do not provide reliable hot particle detection. • Spectral processing using Machine Learning significantly improves detection

  15. Field sampling for monitoring migration and defining the areal extent of chemical contamination

    International Nuclear Information System (INIS)

    Thomas, J.M.; Skalski, J.R.; Eberhardt, L.L.; Simmons, M.A.

    1984-11-01

    Initial research on compositing, field designs, and site mapping oriented toward detecting spills and migration at commercial low-level radioactive or chemical waste sites is summarized. Results indicate that the significance test developed to detect samples containing high levels of contamination when they are mixed with several other samples below detectable limits (composites), will be highly effective with large sample sizes when contaminant levels frequently or greatly exceed a maximum acceptable level. These conditions of frequent and high contaminant levels are most likely to occur in regions of a commercial waste site where the priors (previous knowledge) about a spill or migration are highest. Conversely, initial investigations of Bayes sampling strategies suggest that field sampling efforts should be inversely proportional to the priors (expressed as probabilities) for the occurrence of contamination

  16. Monitoring of Plutonium Contaminated Solid Waste Streams. A technical guide to design and analysis of monitoring systems

    International Nuclear Information System (INIS)

    Birkhoff, G.

    1985-06-01

    The basic information on the Pu content in Pu Contaminated Materials (PCM) is the measurement of radiation emitted by Pu isotopes either spontaneously or due to irradiation by external neutron or gamma-sources. Requirements on measurement accuracy and detection limits should be defined by the operator of a Pu-handling facility in accordance with monitoring objectives in the very beginning of the planning of a monitoring system. Monitoring objectives reflect nuclear safety and radiological protection regulations and the needs for Pu-accountancy of nuclear materials management and safeguards. On considering the possibilities and limitations of radiometric techniques a solution of the monitoring problem is based on appropriate segregation and packaging procedures and records upon matrix and isotopic composition of PCM-items to be measured. The general interrelations between waste item characteristics and measurement uncertainty and detection limit are outlined in the first chapter which is addressed to the system planner. Chapter 2 is devoted to the attention of instrument developers and analysts. It presents in a general approach the correlations between the observed radiation leakage rate, respectively detection signal, and the generating source, e.g. Pu-isotopic content of the examined PCM item. Some practical measurement methods are reviewed and their limitations are indicated. The possible radiometric techniques based on detection of gamma rays from alpha decay (and 241 Am), neutrons from spontaneous fission and (α,n)-reaction and from induced fission reactions by neutron irradiation of Pu isotopes are presented. The measurement uncertainty of a single PCM item measurement is estimated on the basis of the uncertainty of the spatial distributions of source (Pu) and matrix materials. For the estimation of the cumulative error over a large collection of PCM items from a defined PCM-stream a probabilistic approach is suggested

  17. Dip-strip method for monitoring environmental contamination of aflatoxin in food and feed: use of a portable aflatoxin detection kit.

    Science.gov (United States)

    Sashidhar, R B

    1993-10-01

    Aflatoxin contamination of food and feed have gained global significance due to its deleterious effect on human and animal health and its importance in the international trade. The potential of aflatoxin as a carcinogen, mutagen, teratogen, and immunosuppressive agent is well documented. The problem of aflatoxin contamination of food and feed has led to the enactment of various legislation. However, meaningful strategies for implementation of this legislation is limited by nonavailability of simple, cost-effective method for screening and detection of aflatoxin under field conditions. Keeping in mind the analytical constraints in developing countries, a simple-to-operate, rapid, reliable, and cost-effective portable aflatoxin detection kit has been developed. The important components of the kit include a hand-held UV lamp (365 nm, 4 W output), a solvent blender (12,000 rpm) for toxin extraction, and adsorbent-coated dip-strips (polyester film) for detecting and quantifying aflatoxin. Analysis of variance indicates that there were no significant differences between various batches of dip-strips (p > 0.05). The minimum detection limit for aflatoxin B1 was 10 ppb per spot. The kit may find wide application as a research tool in public health laboratories, environmental monitoring agencies, and in the poultry industry.

  18. Concentration of elements in whole-body fish, fish fillets, fish muscle plugs, and fish eggs from the 2008 Missouri Department of Conservation General Contaminant Monitoring Program

    Science.gov (United States)

    May, Thomas W.; Walther, Michael J.; Brumbaugh, William G.; McKee, Michael J.

    2009-01-01

    This report presents the results of a contaminant monitoring survey conducted annually by the Missouri Department of Conservation to examine the levels of selected elemental contaminants in whole-body fish, fish fillets, fish muscle plugs, and fish eggs. Whole-body, fillet, or egg samples of catfish (Ictalurus punctatus, Ictalurus furcatus, Pylodictis olivaris), largemouth bass (Micropterus salmoides), walleye (Sander vitreus), crappie (Pomoxis annularis, Pomoxis nigromaculatus), shovelnose sturgeon (Scaphirhynchus platorynchus), northern hog sucker (Hypentelium nigricans), and Missouri saddled darter (Etheostoma tetrazonum) were collected from 23 sites as part of the Missouri Department of Conservation's Fish Contaminant Monitoring Program. Fish dorsal muscle plugs also were collected from walleye (Sander vitreus) at one of the sites.

  19. Does modifying personal responsibility moderate the mental contamination effect?

    Science.gov (United States)

    Kennedy, Tinisha S; Simonds, Laura M

    2017-12-01

    Mental contamination is the psychological sense of internal dirtiness that arises in the absence of physical contact with a perceived contaminant. Mental contamination can be evoked through imagining perpetrating a moral transgression. This study experimentally evoked mental contamination by asking men to imagine perpetrating a non-consensual kiss. It explored whether reducing sense of personal responsibility for the kiss moderated the mental contamination effect. Male students (N = 60) imagined giving either a consensual or non-consensual kiss. Personal responsibility for the kiss was manipulated in one of two non-consensual kiss conditions by way of the inclusion of social influence information. Feelings of mental contamination were assessed by self-report and through a behavioural index. Mental contamination was successfully induced in the two non-consensual kiss conditions. There was evidence to support the hypothesis that reducing personal responsibility might moderate specific components of mental contamination (shame, dirtiness and urge to cleanse). The effect of responsibility modification was evident in the self-report measures, but not in the behavioural index. The sample comprised male university students which limits generalizability of the findings. The behavioural assessment of mental contamination was limited to a proxy measure. Imagined moral violations are associated with increases in indices of mental contamination. Further research should investigate whether feelings of shame, dirtiness and urge to cleanse are particularly responsive to responsibility modifications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Workplace monitoring for radiation and contamination

    International Nuclear Information System (INIS)

    2004-01-01

    Ionizing radiations cannot be seen, felt or sensed by the human body in any way but excessive exposure to them may have adverse health effects. Radiation measuring instruments are needed in order to detect the presence of such radiations and avoid excessive exposure. The use of appropriate and efficient instruments enables exposures to be controlled and the doses received to be kept as low as reasonably achievable. This Manual explains the basic terminology associated with such measuring instruments and describes the principal types, their construction and typical applications in the workplace. It is important to ensure not only that monitoring is carried out where there is a potential radiation exposure but also that the monitoring instrument is appropriate to the task and that the user places correct interpretations on the results obtained. The Manual will be of most benefit if it forms part of more comprehensive training or is supplemented by the advice of a qualified expert in radiation protection. Some of the instrument tests and calibrations described in this Manual require the services of a qualified expert

  1. Cost-effective sampling of ground water monitoring wells. Revision 1

    International Nuclear Information System (INIS)

    Ridley, M.; Johnson, V.

    1995-11-01

    CS is a systematic methodology for estimating the lowest-frequency sampling schedule for a given groundwater monitoring location which will still provide needed information for regulatory and remedial decision-making. Increases in frequency dictated by remedial actions are left to the judgement of personnel reviewing the recommendations. To become more applicable throughout the life cycle of a ground water cleanup project or for compliance monitoring, several improvements are envisioned, including: chemical signature analysis to identify minimum suites of contaminants for a well, a simple flow and transport model so that sampling of downgradient wells are increased before movement of contamination, and a sampling cost estimation capability. By blending qualitative and quantitative approaches, we hope to create a defensible system while retaining interpretation ease and relevance to decision making

  2. Phytoremediation of Soils Contaminated by Chlorinnated Hydrocarbons

    Science.gov (United States)

    Cho, C.; Sung, K.; Corapcioglu, M.

    2001-12-01

    In recent years, the possible use of deep rooted plants for phytoremediation of soil contaminants has been offered as a potential alternative for waste management, particularly for in situ remediation of large volumes of contaminated soils. Major objectives of this study are to evaluate the effectiveness of a warm season grass (Eastern Gamagrass) and a cool season prairie grass (Annual Ryegrass) in the phytoremediation of the soil contaminated with volatile organic compounds e.g., trichloroethylene (TCE), tetrachloroethylene (PCE), and 1,1,1-trichloroethane (TCA) and to determine the main mechanisms of target contaminant dissipation. The preliminary tests and laboratory scale tests were conducted to identify the main mechanisms for phytoremediation of the target contaminants, and to apply the technique in green house application under field conditions. The results of microcosm and bioreactor experiments showed that volatilization can be the dominant pathway of the target contaminant mass losses in soils. Toxicity tests, conducted in nutrient solution in the growth room, and in the greenhouse, showed that both Eastern gamagrass and Annual ryegrass could grow without harmful effects at up to 400 ppm each of all three contaminants together. Preliminary greenhouse experimentw were conducted with the 1.5 m long and 0.3 m diameter PVC columns. Soil gas concentrations monitored and microbial biomass in bulk and rhizosphere soil, root properties, and contaminant concentration in soil after 100 days were analyzed. The results showed that the soil gas concentration of contaminants has rapidly decreased especially in the upper soil and the contaminant concentraitons in soil were also significantly decreased to 0.024, 0.228, and 0.002 of C/Co for TCE, PCE and TCA, respectively. Significant plant effects were not found however showed contaminant loss through volatilization and plant contamination by air.

  3. Blast fracturing of bedrock to enhance recovery of contaminated groundwater

    International Nuclear Information System (INIS)

    Holzman, L.R.; Harvey, E.M.; McKee, R.C.E.; Katsabanis, T.

    1992-01-01

    Petroleum hydrocarbons releasd from a pipeline at a site in southern Ontario had contaminated a fractured dolostone bedrock aquifer. To remediate the site, contaminated groundwater was pumped from the downgradient edge of the hydrocarbon plume and injected into an upgradient area after treatment. Contaminant flow pathways in the fractured bedrock aquifer were found to be complex and erratic. It was anticipated that contaminated groundwater could escape the influence of a line of closely spaced recovery wells. In order to capture the migrating contaminants effectively, improve communication between recovery wells, and optimize pumping efficiencies, a rubble zone was created by drilling and blasting the rock. Using 140 blastholes, the bedrock was fractured to a depth of 4 m over a distance of 200 m. Similarly, an additional 80 blastholes were used to blast fracture 100 m of bedrock to a depth of 4 m in the recharge area to enhance injection of treated water to the aquifer. Various blasthole spacings and explosive loadings and patterns were tested to fracture the rock effectively while minimizing the impact on the nearby pipeline and neighboring residences. Vibrations were carefully monitored using several seismographs. Pump tests conducted before and after the blast indicated the hydraulic connection between the naturally occurring fractures had greatly improved. Monitoring conducted after startup of the pump-treat-and-inject system has confirmed the fracturing provides effective capture and injection of the groundwater. 3 refs., 3 figs., 1 tab

  4. Radioactive Contamination of Agricultural Products in Poland

    International Nuclear Information System (INIS)

    Muszynski, W.; Grabowski, D.; Rubel, B.; Kurowski, W.; Swietochowska, J.; Smagala, G.

    2003-01-01

    Radiological contamination of the environment is caused by nuclear activities on the globe: nuclear weapon tests and the Chernobyl accident. The transfer of radionuclides to the organism via ingestion is one of the sources of doses obtained by people. To assess the doses received by humans the intake of isotopes with daily diet was defined. The concentration of radionuclides in foodstuffs was determined. The network of Service for Measurement of Radioactive Contamination systematically controls all kinds of important agricultural products such as milk, meat, vegetables, fruit, cereals and forest products: mushrooms, blueberries etc. Measurement stations involved in food monitoring act within Sanitary-Epidemiological Stations, Veterinary Hygiene Units and Chemical-Agricultural Stations. All activities are co-ordinated by the Central Laboratory for Radiological Protection. The level of activity of caesium isotopes has regularly been monitored in collected samples originating from different administrative districts of Poland. Since 1994 the 134 Cs concentration has been below the detection limit. The activity of 137 Cs has been measured to determine long-term effect of the accident on the contamination of milk, meat and other foodstuffs. (orig.)

  5. Effects of pesticides and contaminants on neotropical migrants

    Science.gov (United States)

    Nicholas W. Gard; Michael J. Hooper; Richard S. Bennett

    1993-01-01

    Many agricultural pesticides and industrial contaminants are capable of adversely affecting birds through direct effects such as elevated mortality rates and decreased reproductive success or indirectly by modifying habitat composition or food availability. Although neotropical migrants are potentially exposed to these contaminants on their breeding, migratory and...

  6. Monitoring in radiological protection scheme; Pemonitoran dalam skim perlindungan radiologi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-12-31

    The chapter briefly discussed the following subjects: function and responsibility of the monitoring, planning of monitoring programme i.e working area for external radiation, monitoring of workers for external radiation, monitoring of working area for surface contamination, monitoring of working area for air contamination, monitoring of workers for internal contamination, and the evaluation of monitoring results.

  7. Effects of sorption behaviour on contaminant migration

    International Nuclear Information System (INIS)

    Melnyk, T.W.

    1985-11-01

    The effects of sorption behaviour on contaminant migration in groundwater systems are varied. Retardation of migration and dispersive effects can vary widely and contaminant concentration profiles can take a number of different shapes. This report examines the nature of some of these effects, especially those due to sorption behaviours that are dependent on the concentration of the contaminant in the groundwater. The effects are calculated using, in most cases, analytical solutions to the chemical equations imbedded in a simple reaction-cell or box-model transport algorithm. The hydrogeological parameters are held constant, and radioactive decay and hydrodynamic dispersion are excluded. A general discussion of the role of sorption equations in transport modelling is followed by presentation of migration results for a number of models of sorption behaviour varying from linear isotherms, Langmuir, Freundlich and ion-exchange isotherms, to precipitation reactions and multiple-site sorption reactions. The results are compared and general conclusions are drawn about the various migration behaviours calculated. The conclusions are that equilibrium sorption of trace contaminants can be modelled with linear isotherms (constant distribution coefficients or constant retardation factors) but the evaluation and extrapolation of the distribution coefficient are not easy. Nonlinear isotherms lead to unsymmetrical migration fronts. A comparison of Freundlich and linear isotherms is made. Sorption/desorption kinetic factors can be significant on the time scale of laboratory experiments and can cause large dispersive effects. Slow but important reactions can be missed altogether. Precipitation or mineralization behaviour cannot be modelled with constant distribution coefficients. Also, mineralization reactions can be kinetically slow even on the geological time scale. 89 refs

  8. Unmanned aerial vehicles for the assessment and monitoring of environmental contamination: An example from coal ash spills.

    Science.gov (United States)

    Messinger, Max; Silman, Miles

    2016-11-01

    Unmanned aerial vehicles (UAVs) offer new opportunities to monitor pollution and provide valuable information to support remediation. Their low-cost, ease of use, and rapid deployment capability make them ideal for environmental emergency response. Here we present a UAV-based study of the third largest coal ash spill in the United States. Coal ash from coal combustion is a toxic industrial waste material present worldwide. Typically stored in settling ponds in close proximity to waterways, coal ash poses significant risk to the environment and drinking water supplies from both chronic contamination of surface and ground water and catastrophic pond failure. We sought to provide an independent estimate of the volume of coal ash and contaminated water lost during the rupture of the primary coal ash pond at the Dan River Steam Station in Eden, NC, USA and to demonstrate the feasibility of using UAVs to rapidly respond to and measure the volume of spills from ponds or containers that are open to the air. Using structure-from-motion (SfM) imagery analysis techniques, we reconstructed the 3D structure of the pond bottom after the spill, used historical imagery to estimate the pre-spill waterline, and calculated the volume of material lost. We estimated a loss of 66,245 ± 5678 m 3 of ash and contaminated water. The technique used here allows rapid response to environmental emergencies and quantification of their impacts at low cost, and these capabilities will make UAVs a central tool in environmental planning, monitoring, and disaster response. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Solidification treatment of thiophene and BTEX contaminated soils

    International Nuclear Information System (INIS)

    Zarlinski, S.J.; Kingham, N.W.; Blevins, J.

    1995-01-01

    Contamination at the McColl Superfund Site, located in Fullerton, California, is due to the disposal, in pits, of spent sulfuric acid sludge from the production of aviation fuel. A treatability study was performed to evaluate the electiveness of in situ solidification treatment of materials contaminated with high concentrations of benzene, toluene, ethylbenzene, and xylenes (BTEX), as well as thiophene and other organic compounds. The contaminated materials were extremely acidic (pH<1) and had high organic and sulfur contents of greater than 70 percent and 10 percent, respectively. A total of 150 mixtures were screened to evaluate the effectiveness of 15 reagents. Based on the preliminary screening results, six mixtures were selected as being the most effective at treating the contaminated materials. Comprehensive evaluations of the candidate mixtures included (1) quantitative glovebag volatilization studies, (2) chemical characterization of the treated materials, (3) strength characterizations at multiple cure times of up to 60 days, (4) emissions monitoring of the treated materials at cure times of 7 and 14 days, and (5) the evaluation of oxidation reagents for treatment of the thiophene contamination. The treatability study demonstrated that solidification treatment is an effective alternative for remediation of the thiophene and BTEX contaminated materials

  10. Resuspended contaminated sediments cause sublethal stress to oysters: A biomarker differentiates total suspended solids and contaminant effects.

    Science.gov (United States)

    Edge, Katelyn J; Dafforn, Katherine A; Simpson, Stuart L; Ringwood, Amy H; Johnston, Emma L

    2015-06-01

    Resuspended contaminated sediments represent an important route of contaminant exposure for aquatic organisms. During resuspension events, filter-feeding organisms are exposed to contaminants, in both the dissolved form (at the gills) and the particulate form (in the digestive system). In addition, these organisms must manage the physical stress associated with an increase in total suspended solids (TSS). To date, few studies have experimentally compared the contributions to biological stress of contaminated and clean suspended solids. The authors mixed field-collected sediments (cellular biomarkers (lysosomal membrane stability, lipid peroxidation, and glutathione) were measured to evaluate sublethal toxicity. Lysosomal membrane stability was the most sensitive biomarker for distinguishing effects from resuspended contaminated sediments, as increasing amounts of contaminated TSS increased lysosomal membrane destabilization. The authors' results illustrate the importance of considering contaminant exposures from resuspended sediments when assessing the toxicity of contaminants to aquatic organisms. © 2015 SETAC.

  11. In-situ protein determination to monitor contamination in a centrifugal partition chromatograph.

    Science.gov (United States)

    Bouiche, Feriel; Faure, Karine

    2017-05-15

    Centrifugal partition chromatography (CPC) works with biphasic liquid systems including aqueous two-phase systems. Metallic rotors are able to retain an aqueous stationary phase able to purify proteins. But the adhesion of proteins to solid surface may pose a cross-contamination risk during downstream processes. So it is of utmost importance to ensure the cleanliness of the equipment and detect possible protein contamination in a timely manner. Thereby, a direct method that allows the determination of the effective presence of proteins and the extent of contamination in the metallic CPC rotors was developed. This in-situ method is derived from the Amino Density Estimation by Colorimetric Assay (ADECA) which is based on the affinity of a dye, Coomassie Brillant Blue (CBB), with protonated N + groups of the proteins. In this paper, the ADECA method was developed dynamically, on a 25 mL stainless-steel rotor with various extents of protein contaminations using bovine serum albumin (BSA) as a fouling model. The eluted CBB dye was quantified and found to respond linearly to BSA contamination up to 70 mg injected. Limits of detection and quantification were recorded as 0.9 mg and 3.1 mg, respectively. While the non-specific interactions between the dye and the rotor cannot currently be neglected, this method allows for in situ determination of proteins contamination and should contribute to the development of CPC as a separation tool in protein purification processes. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Nanomaterial-enabled Rapid Detection of Water Contaminants.

    Science.gov (United States)

    Mao, Shun; Chang, Jingbo; Zhou, Guihua; Chen, Junhong

    2015-10-28

    Water contaminants, e.g., inorganic chemicals and microorganisms, are critical metrics for water quality monitoring and have significant impacts on human health and plants/organisms living in water. The scope and focus of this review is nanomaterial-based optical, electronic, and electrochemical sensors for rapid detection of water contaminants, e.g., heavy metals, anions, and bacteria. These contaminants are commonly found in different water systems. The importance of water quality monitoring and control demands significant advancement in the detection of contaminants in water because current sensing technologies for water contaminants have limitations. The advantages of nanomaterial-based sensing technologies are highlighted and recent progress on nanomaterial-based sensors for rapid water contaminant detection is discussed. An outlook for future research into this rapidly growing field is also provided. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Elimination of quarterly urinalysis of radiation workers based on detection capability of portal monitors for internal contamination

    International Nuclear Information System (INIS)

    Ramanuja, Jayalakshmi

    2012-01-01

    Covidien is a radiopharmaceutical manufacturing company in Missouri, USA. The facility produces radionuclides for diagnostic and therapeutic use. The radionuclides of interest, 123 I, 67 Ga, 99 Mo, 99m Tc, 201 Tl, 111 In, and 131 I are fairly short lived with the exception of 51 Cr. The operating license document for the company mandated quarterly urinalysis (bioassay) of all radiation workers in the facility. This was labor intensive and did not enhance the quality of radiation protection program. Nuclear Regulatory Commission (NRC) required a technical basis to prove that there was no compromise in the radiological safety and accurate dose assessment in the event of internal contamination of radiation workers if quarterly urinalysis was discontinued. Measurements in a phantom, gamma spectroscopy analysis, as well as calculations showed that there was no need to perform quarterly urinalysis and that portal monitors and other radiological controls were sufficient to detect any chronic or acute intake of radioactivity by radiation workers. Technical evaluation showed Portal monitors can detect an Effective Dose Equivalent of 0.1 mSv (10 mrem) in a year. NRC allowed revision of operating license document and operating procedures to discontinue quarterly urinalysis. (author)

  14. Global styrene oligomers monitoring as new chemical contamination from polystyrene plastic marine pollution.

    Science.gov (United States)

    Kwon, Bum Gun; Koizumi, Koshiro; Chung, Seon-Yong; Kodera, Yoichi; Kim, Jong-Oh; Saido, Katsuhiko

    2015-12-30

    Polystyrene (PS) plastic marine pollution is an environmental concern. However, a reliable and objective assessment of the scope of this problem, which can lead to persistent organic contaminants, has yet to be performed. Here, we show that anthropogenic styrene oligomers (SOs), a possible indicator of PS pollution in the ocean, are found globally at concentrations that are higher than those expected based on the stability of PS. SOs appear to persist to varying degrees in the seawater and sand samples collected from beaches around the world. The most persistent forms are styrene monomer, styrene dimer, and styrene trimer. Sand samples from beaches, which are commonly recreation sites, are particularly polluted with these high SOs concentrations. This finding is of interest from both scientific and public perspectives because SOs may pose potential long-term risks to the environment in combination with other endocrine disrupting chemicals. From SOs monitoring results, this study proposes a flow diagram for SOs leaching from PS cycle. Using this flow diagram, we conclude that SOs are global contaminants in sandy beaches around the world due to their broad spatial distribution. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Overview of Emerging Contaminants and Associated Human Health Effects

    Science.gov (United States)

    Lei, Meng; Zhang, Lun; Lei, Jianjun; Zong, Liang; Li, Jiahui; Wu, Zheng; Wang, Zheng

    2015-01-01

    In recent decades, because of significant progress in the analysis and detection of trace pollutants, emerging contaminants have been discovered and quantified in living beings and diverse environmental substances; however, the adverse effects of environmental exposure on the general population are largely unknown. This review summarizes the conclusions of the comprehensive epidemic literature and representative case reports relevant to emerging contaminants and the human body to address concerns about potential harmful health effects in the general population. The most prevalent emerging contaminants include perfluorinated compounds, water disinfection byproducts, gasoline additives, manufactured nanomaterials, human and veterinary pharmaceuticals, and UV-filters. Rare but statistically meaningful connections have been reported for a number of contaminants and cancer and reproductive risks. Because of contradictions in the outcomes of some investigations and the limited number of articles, no significant conclusions regarding the relationship between adverse effects on humans and extents of exposure can be drawn at this time. Here, we report that the current evidence is not conclusive and comprehensive and suggest prospective cohort studies in the future to evaluate the associations between human health outcomes and emerging environmental contaminants. PMID:26713315

  16. Overview of Emerging Contaminants and Associated Human Health Effects

    Directory of Open Access Journals (Sweden)

    Meng Lei

    2015-01-01

    Full Text Available In recent decades, because of significant progress in the analysis and detection of trace pollutants, emerging contaminants have been discovered and quantified in living beings and diverse environmental substances; however, the adverse effects of environmental exposure on the general population are largely unknown. This review summarizes the conclusions of the comprehensive epidemic literature and representative case reports relevant to emerging contaminants and the human body to address concerns about potential harmful health effects in the general population. The most prevalent emerging contaminants include perfluorinated compounds, water disinfection byproducts, gasoline additives, manufactured nanomaterials, human and veterinary pharmaceuticals, and UV-filters. Rare but statistically meaningful connections have been reported for a number of contaminants and cancer and reproductive risks. Because of contradictions in the outcomes of some investigations and the limited number of articles, no significant conclusions regarding the relationship between adverse effects on humans and extents of exposure can be drawn at this time. Here, we report that the current evidence is not conclusive and comprehensive and suggest prospective cohort studies in the future to evaluate the associations between human health outcomes and emerging environmental contaminants.

  17. Development of plastic scintillator based food radioactivity contamination monitoring system

    International Nuclear Information System (INIS)

    Parihar, A.; Sahani, R.M.; Mahala, V.K.; Vaijapurkar, S.G.

    2016-01-01

    Radioactivity is naturally present in soil, water and food stuffs. Food can be contaminated after discharge of radioactivity into the environment from industries that concentrate natural radionuclide and from civil or military nuclear operations. The contamination can be in three ways; by direct deposition, through the food chain and induced radioactivity due to exposure of high neutron flux. The health effects on human depend on the type of radionuclide and the length of time people are exposed to it. The studies of fission product behaviour in the food chain have revealed radionuclide Strontium-90, Caesium 137 and Iodine-131 are of major concern. Plastic scintillator is already developed indigenously at Defence Laboratory, Jodhpur. Efforts has been made to develop a portable field instrument using plastic scintillator for assessment of beta ( 90 Sr) and gamma ( 137 Cs and 131 I) radioactivity in food

  18. A Comparison of growth on mercuric chloride for three Lemnaceae species reveals differences in growth dynamics that effect their suitability for use in either monitoring or remediating ecosystems contaminated with mercury.

    Science.gov (United States)

    Yang, Jingjing; Li, Gaojie; Bishopp, Anthony; Heenatigala, P. P. M.; Hu, Shiqi; Chen, Yan; Wu, Zhigang; Kumar, Sunjeet; Duan, Pengfei; Yao, Lunguang; Hou, Hongwei

    2018-04-01

    Mercury (Hg) is a toxic heavy metal that can alter the ecological balance when it contaminates aquatic ecosystems. Previously, researchers have used various Lemnaceae species either to monitor and/or remove heavy metals from freshwater systems. As Hg contamination is a pressing issue for aquatic systems worldwide, we assessed its impact on the growth of three commonly species of Lemnaceae - Lemna gibba 6745, Lemna minor 6580 and Spirodela polyrhiza 5543. We exposed plants to different concentrations of mercuric chloride (HgCl2) and monitored their growth, including relative growth rate, frond number, and fresh weight. These data were coupled with measurements of starch content, levels of photosynthetic pigment and the activities of antioxidant substances. The growth of all three lines showed significant negative correlations with Hg concentrations, and starch content, photosynthetic pigment, soluble protein and antioxidant enzymes levels were all clearly affected. Our results indicate that the L. gibba line used in this study was the most suitable of the three for biomonitoring of water contaminated with Hg. Accumulation of Hg was highest in the S. polyrhiza line with a bioconcentration factor over 1000, making this line the most suitable of the three tested for use in an Hg bioremediation system.

  19. A Comparison of Growth on Mercuric Chloride for Three Lemnaceae Species Reveals Differences in Growth Dynamics That Effect Their Suitability for Use in Either Monitoring or Remediating Ecosystems Contaminated With Mercury

    Directory of Open Access Journals (Sweden)

    Jingjing Yang

    2018-04-01

    Full Text Available Mercury (Hg is a toxic heavy metal that can alter the ecological balance when it contaminates aquatic ecosystems. Previously, researchers have used various Lemnaceae species either to monitor and/or remove heavy metals from freshwater systems. As Hg contamination is a pressing issue for aquatic systems worldwide, we assessed its impact on the growth of three commonly species of Lemnaceae- Lemna gibba 6745, Lemna minor 6580 and Spirodela polyrhiza 5543. We exposed plants to different concentrations of mercuric chloride (HgCl2 and monitored their growth, including relative growth rate, frond number (FN, and fresh weight (FW. These data were coupled with measurements of starch content, levels of photosynthetic pigment and the activities of antioxidant substances. The growth of all three lines showed significant negative correlations with Hg concentrations, and starch content, photosynthetic pigment, soluble protein and antioxidant enzymes levels were all clearly affected. Our results indicate that the L. gibba line used in this study was the most suitable of the three for biomonitoring of water contaminated with Hg. Accumulation of Hg was highest in the S. polyrhiza line with a bioconcentration factor over 1,000, making this line the most suitable of the three tested for use in an Hg bioremediation system.

  20. Unrestricted release measurements with ambient air ionization monitors

    International Nuclear Information System (INIS)

    MacArthur, D.; Gunn, R.; Dockray, T.; Luff, C.

    1999-01-01

    Radiation monitoring systems based on the long-range alpha detection (LRAD) technique, such as the BNFL Instruments IonSens trademark, provide a single contamination measurement for an entire object rather than the more familiar individual readings for smaller surface areas. The LRAD technique relies on the ionization of ambient air molecules by alpha particles, and the subsequent detection of these ions, rather than direct detection of the alpha particles themselves. A single monitor can detect all of the ions produced over a large object and report a total contamination level for the entire surface of that object. However, both the unrestricted release limits specified in USDOE Order 5400.5 (and similar documents in other countries), and the definitions of radioactive waste categories, are stated in terms of contamination per area. Thus, conversion is required between the total effective contamination as measured by the LRAD-based detector and the allowable release limits. In addition, since the release limits were not written assuming an averaging detector system, the method chosen to average the assumed contamination over the object can have a significant impact on the effective sensitivity of the detector

  1. Effects of chemical contamination on HDPE - thermo-mechanical and characterisation properties

    International Nuclear Information System (INIS)

    Ashraf, G.

    2002-01-01

    Studying the effects of chemical contamination on HDPE is an important precursor in recycling of plastic packaging and polymer reprocessing. This research involves and discusses the results of an in-depth investigation into the effects of chemically contaminating, using various acids, commercial grade high density polyethylene (HDPE) used commonly in packaging applications. An extensive formulation study was conducted and it became obvious that in some cases degradation had occurred to HDPE when chemically contaminated with particular functional group types. The functional groups in contaminated HDPE were successfully identified. A variety of analytical techniques such as Fourier transform Infra-red spectroscopy, X-ray Florescence, x-ray photo electron spectroscopy could identify compounds such as HCl acid, HNO/sub 3/ acid and other related contaminants. Some chemical additives had effects on the mechanical and thermal properties when added in the most appropriate concentration. The results have shown lower tensile modulus and strength tensile elongation, lower modular weight, melt flow index and crystallinity. The amount of contaminant concentration, the type of chemical functional groups used and the type of test selected to affect degradation are important factors in proving the effects of chemical contamination on HDPE in the melt state. (author)

  2. Innovative Strategy For Long Term Monitoring Of Metal And Radionuclide Plumes

    International Nuclear Information System (INIS)

    Eddy-Dilek, Carol; Millings, Margaret R.; Looney, Brian B.; Denham, Miles E.

    2014-01-01

    to improved monitoring while simultaneously reducing costs. This paradigm is being tested at the SRS F-Area where an innovative passive remedial system is being monitored and evaluated over the long term prior to traditional regulatory closure. Contaminants being addressed at this site are uranium, strontium-90, iodine-129, and tritium. We believe that the proposed strategies will be more effective in early identification of potential risks; these strategies will also be cost effective because controlling variables are relatively simple to measure. These variables also directly reflect the evolution of the plume through time, so that the monitoring strategy can be modified as the plume 'ages'. This transformational long-term monitoring paradigm will generate large cost savings to DOE, other federal agencies and industry and will provide improved performance and leading indicators of environmental management performance

  3. Innovative Strategy For Long Term Monitoring Of Metal And Radionuclide Plumes

    Energy Technology Data Exchange (ETDEWEB)

    Eddy-Dilek, Carol; Millings, Margaret R.; Looney, Brian B.; Denham, Miles E.

    2014-01-08

    to improved monitoring while simultaneously reducing costs. This paradigm is being tested at the SRS F-Area where an innovative passive remedial system is being monitored and evaluated over the long term prior to traditional regulatory closure. Contaminants being addressed at this site are uranium, strontium-90, iodine-129, and tritium. We believe that the proposed strategies will be more effective in early identification of potential risks; these strategies will also be cost effective because controlling variables are relatively simple to measure. These variables also directly reflect the evolution of the plume through time, so that the monitoring strategy can be modified as the plume 'ages'. This transformational long-term monitoring paradigm will generate large cost savings to DOE, other federal agencies and industry and will provide improved performance and leading indicators of environmental management performance.

  4. Assisted bioremediation tests on three natural soils contaminated with benzene

    Directory of Open Access Journals (Sweden)

    Maria Manuela Carvalho

    2015-07-01

    Full Text Available Bioremediation is an attractive and useful method of remediation of soils contaminated with petroleum hydrocarbons because it is simple to maintain, applicable in large areas, is economic and enables an effective destruction of the contaminant. Usually, the autochthone microorganisms have no ability to degrade these compounds, and otherwise, the contaminated sites have inappropriate environmental conditions for microorganism’s development. These problems can be overcome by assisted bioremediation (bioaugmentation and/or biostimulation. In this study the assisted bioremediation capacity on the rehabilitation of three natural sub-soils (granite, limestone and schist contaminated with benzene was evaluated. Two different types of assisted bioremediation were used: without and with ventilation (bioventing. The bioaugmentation was held by inoculating the soil with a consortium of microorganisms collected from the protection area of crude oil storage tanks in a refinery. In unventilated trials, biostimulation was accomplished by the addition of a nutrient mineral media, while in bioventing oxygen was also added. The tests were carried out at controlled temperature of 25 ºC in stainless steel columns where the moist soil contaminated with benzene (200 mg per kg of soil occupied about 40% of the column’s volume. The processes were daily monitored in discontinued mode. Benzene concentration in the gas phase was quantified by gas chromatography (GC-FID, oxygen and carbon dioxide concentrations were monitored by respirometry. The results revealed that the three contaminated soils were remediated using both technologies, nevertheless, the bioventing showed faster rates. With this work it was proved that respirometric analysis is an appropriate instrument for monitoring the biological activity.

  5. The Effect of Airborne Contaminants on Fuel Cell Performance and Durability

    Energy Technology Data Exchange (ETDEWEB)

    St-Pierre, Jean [Univ. of Hawaii, Manoa, HI (United States); Pasaogullari, Ugur [Univ. of Connecticut, Storrs, CT (United States); Cheng, Tommy [Ballard Power Systems, Burnaby, BC (Canada); Collins, William [WPCSOL, East Windsor, CT (United States)

    2017-09-18

    The impact of contaminants on fuel cell performance was examined to document air filter specifications (prevention) and devise recovery procedures (maintenance) that are effective at the system level. Eight previously undocumented airborne contaminants were selected for detailed studies and characterization data was used to identify operating conditions that intensifying contamination effects. The use of many and complementary electrochemical, chemical and physical characterization methods and the derivation of several mathematical models supported the formulation of contamination mechanisms and the development of recovery procedures. The complexity of these contamination mechanisms suggests a shift to prevention and generic maintenance measures. Only two of the selected contaminants led to cell voltage losses after injection was interrupted. Proposed recovery procedures for calcium ions, a component of road de-icers, dessicants, fertilizers and soil conditioners, were either ineffective or partly effective, whereas for bromomethane, a fumigant, the cell voltage was recovered to its initial value before contamination by manipulating and sequencing operating conditions. However, implementation for a fuel cell stack and system remains to be demonstrated. Contamination mechanisms also led to the identification of membrane durability stressors. All 8 selected contaminants promote the formation of hydrogen peroxide, a known agent that can produce radicals that attack the ionomer and membrane molecular structure whereas the dehydrating effect of calcium ions on the ionomer and membrane increases their brittleness and favors the creation of pinholes under mechanical stresses. Data related to acetylene, acetonitrile and calcium ions are emphasized in the report.

  6. Design of tool monitor simulator

    International Nuclear Information System (INIS)

    Yao Yonggang; Deng Changming; Zhang Jia; Meng Dan; Zhang Lu; Wang Zhi'ai; Shen Yang

    2011-01-01

    It is based on tool monitor in Qinshan Nuclear Power Plant for the object of study, and manufacture a tool monitor simulator. The device is designed to automatically emulate-monitor the contamination level of objects for training students. Once if the tool monitor reports the contamination, the students can handle properly. The brief introduction of main function and system design of the simulator are presented in the paper. (authors)

  7. Atrazine Contamination and Potential Health Effects on Freshwater Mussel Uniandra contradens Living in Agricultural Catchment at Nan Province, Thailand

    Directory of Open Access Journals (Sweden)

    Tongchai Thitiphuree

    2013-01-01

    Full Text Available Seasonal cultivation in northern part of Thailand leads to widely uses of agrochemicals especially atrazine herbicide. To examine whether an intensive use of atrazine could lead to contamination in aquatic environment, sediment and water were collected from an agricultural catchment in Nan Province during 2010-2011 and subjected to analysis for atrazine by GC-MS. The results showed that detectable levels of atrazine were found in water (0.16 µg/ml and sediment (0.23 µg/g of the catchment. To monitor potential effects of atrazine on aquatic animals, a freshwater mussel Uniandra contradens was used as a sentinel species for bioaccumulation and potential health effects. Mussels collected from the catchment during 2010-2011 were subjected to analysis for atrazine residue in tissue and condition factor based on body weight and shell length. The results showed that detectable levels of atrazine were found in mussel tissue with the highest level (8.40  2.06 ng/g in late wet season when runoff from heavy rain was evidenced. Condition factor, an indicative of overall health, showed a significant negative correlation with atrazine residue in the tissue. This information could be used as part of the monitoring program for herbicide contamination and potential health effects in agricultural environment.

  8. Performance of passive samplers for monitoring estuarine water column concentrations: 2. Emerging contaminants.

    Science.gov (United States)

    Perron, Monique M; Burgess, Robert M; Suuberg, Eric M; Cantwell, Mark G; Pennell, Kelly G

    2013-10-01

    Measuring dissolved concentrations of emerging contaminants, such as polybrominated diphenyl ethers (PBDEs) and triclosan, can be challenging due to their physicochemical properties resulting in low aqueous solubilities and association with particles. Passive sampling methods have been applied to assess dissolved concentrations in water and sediments primarily for legacy contaminants. Although the technology is applicable to some emerging contaminants, the use of passive samplers with emerging contaminants is limited. In the present study, the performance of 3 common passive samplers was evaluated for sampling PBDEs and triclosan. Passive sampling polymers included low-density polyethylene (PE) and polyoxymethylene (POM) sheets, and polydimethylsiloxane (PDMS)-coated solid-phase microextraction (SPME) fibers. Dissolved concentrations were calculated using measured sampler concentrations and laboratory-derived partition coefficients. Dissolved tri-, tetra-, and pentabrominated PBDE congeners were detected at several of the study sites at very low pg/L concentrations using PE and POM. Calculated dissolved water concentrations of triclosan ranged from 1.7 ng/L to 18 ng/L for POM and 8.8 ng/L to 13 ng/L for PE using performance reference compound equilibrium adjustments. Concentrations in SPME were not reported due to lack of detectable chemical in the PDMS polymer deployed. Although both PE and POM were found to effectively accumulate emerging contaminants from the water column, further research is needed to determine their utility as passive sampling devices for emerging contaminants. © 2013 SETAC.

  9. Ground-Water Protection and Monitoring Program

    Energy Technology Data Exchange (ETDEWEB)

    Dresel, P.E.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the ground-water protection and monitoring program strategy for the Hanford Site in 1994. Two of the key elements of this strategy are to (1) protect the unconfined aquifer from further contamination, and (2) conduct a monitoring program to provide early warning when contamination of ground water does occur. The monitoring program at Hanford is designed to document the distribution and movement of existing ground-water contamination and provides a historical baseline for evaluating current and future risk from exposure to the contamination and for deciding on remedial action options.

  10. Ground-Water Protection and Monitoring Program

    International Nuclear Information System (INIS)

    Dresel, P.E.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the ground-water protection and monitoring program strategy for the Hanford Site in 1994. Two of the key elements of this strategy are to (1) protect the unconfined aquifer from further contamination, and (2) conduct a monitoring program to provide early warning when contamination of ground water does occur. The monitoring program at Hanford is designed to document the distribution and movement of existing ground-water contamination and provides a historical baseline for evaluating current and future risk from exposure to the contamination and for deciding on remedial action options

  11. Radioactive Plumes Monitoring Simulator

    International Nuclear Information System (INIS)

    Kapelushnik, I.; Sheinfeld, M.; Avida, R.; Kadmon, Y.; Ellenbogen, M.; Tirosh, D.

    1999-01-01

    The Airborne Radiation Monitoring System (ARMS) monitors air or ground radioactive contamination. The contamination source can be a radioactive plume or an area contaminated with radionuclides. The system is based on two major parts, an airborne unit carried by a helicopter and a ground station carried by a truck. The system enables real time measurement and analysis of radioactive plumes as well as post flight processing. The Radioactive Plumes Monitoring Simulator purpose is to create a virtual space where the trained operators experience full radiation field conditions, without real radiation hazard. The ARMS is based on a flying platform and hence the simulator allows a significant reduction of flight time costs

  12. Environmental Contamination Genetic Consequences Monitoring on the Former Semipalatinsk Test Site: General Approach

    International Nuclear Information System (INIS)

    Seisebaev, A.T.; Bakhtin, M.M.; Zhapbasov, R.Zh.

    1998-01-01

    For an objective assessment of nuclear test consequences for the environment it is necessary, together with the investigation of radiation situation, to study live biological systems, particularly the genetic effects of chronic ionizing radiation. The long staying of plants and animals on the territories with the elevated radiation background level can lead to the change of organism genetic system. In this connection the monitoring of chronically exposed natural populations is of particular interest and can serve as the objective indicator of the scale of natural biota genetic damage. Basing on the results obtained during plant and animal studies one can indirectly assess the hazard of people genetic damage. Besides, studying the mutational process on natural populations exposed to the chronic ionizing radiation one can reveal new regularities, which are impossible to be detected in the laboratory conditions, and new aspects of radiation genetics. The issue of radiation adaptation of organisms affected by the various doses of ionizing radiation is very acute. The prerequisite of organism adaptation to the certain radiation background is genetic heterogeneity of individuals comprising the population and selection of radiation-induced individuals, which are the carriers of the mutation of high radioresistance. The uniqueness of the Semipalatinsk Test site and the necessity of long-term investigations of the nuclear test consequences for the environment demand the elaboration of principles for organization and utilization of natural population genetic monitoring. Radiation-genetic monitoring is the long-term observation of palpitation gene pool conditions, assessment and forecast of their spatial and time alteration, determination of limits of changes admitted under the condition of environmental radioactive contamination. It includes a series of the main research directions and has quite certain methodological peculiarities. In this paper we discuss the tasks of

  13. The field application of an immunoassay-based test for petroleum fuels contamination in groundwater

    International Nuclear Information System (INIS)

    Carter, K.R.

    1994-01-01

    The recent development of low-cost, rapid field analytical tests for petroleum fuels based on immunoassay technology has provided an on-site tool for the cost-effective, accurate assessment of groundwater contamination. The method allows for rapid, direct measurement of contaminant concentration. The method has been used for a variety of applications including surface water runoff testing and groundwater monitoring well siting. The PETRO RISc Water Test can be used to substantially reduce the cost of monitoring well installation. Current, monitoring wells are placed based on knowledge of the location of the source of contamination, the size of the release, the time elapsed since the release began, and the hydrogeology of the site. While the location of the source is generally known with some precision, the hydrogeology of the site and the timing of the release rarely are. This results in the need for an ''educated guess'' regarding the drilling location for monitoring wells that are installed to provide long term feedback on groundwater contamination. The tests have the greatest sensitivity to aliphatic compounds in the range of six to ten carbons and aromatic compounds such as toluene, xylene, and naphthalene

  14. Radiolabelled substrates for studying biological effects of trace contaminants

    International Nuclear Information System (INIS)

    1975-01-01

    A programme of coordinated isotopic tracer-aided investigations of the biological side-effects of foreign chemical residues in food and agriculture, initiated in 1973, was reviewed. The current status of representative investigations from the point of view of techniques and priorities was assessed. Such investigations involved radioactive substrates for studying DNA injury and its repair; 14 C-labelled acetylcholine as substrate for measuring enzyme inhibition due to the presence of, or exposure to, anticholinesteratic contaminants; radioactive substrates as indication of side-effects in non-target organisms and of their comparative susceptibilities; radioactive substrates as indicators of persistence or biodegradability of trace contaminants of soil or water; and labelled pools for studying the biological side-effects of trace contaminants. Priorities were identified

  15. Monitoring the bio-stimulation of hydrocarbon-contaminated soils by measurements of soil electrical properties, and CO2 content and its 13C/12C isotopic signature

    Science.gov (United States)

    Noel, C.; Gourry, J.; Ignatiadis, I.; Colombano, S.; Dictor, M.; Guimbaud, C.; Chartier, M.; Dumestre, A.; Dehez, S.; Naudet, V.

    2013-12-01

    Hydrocarbon contaminated soils represent an environmental issue as it impacts on ecosystems and aquifers. Where significant subsurface heterogeneity exists, conventional intrusive investigations and groundwater sampling can be insufficient to obtain a robust monitoring of hydrocarbon contaminants, as the information they provide is restricted to vertical profiles at discrete locations, with no information between sampling points. In order to obtain wider information in space volume on subsurface modifications, complementary methods can be used like geophysics. Among geophysical methods, geoelectrical techniques such as electrical resistivity (ER) and induced polarization (IP) seem the more promising, especially to study the effects of biodegradation processes. Laboratory and field geoelectrical experiments to characterize soils contaminated by oil products have shown that mature hydrocarbon-contaminated soils are characterized by enhanced electrical conductivity although hydrocarbons are electrically resistive. This high bulk conductivity is due to bacterial impacts on geological media, resulting in changes in the chemical and physical properties and thus, to the geophysical properties of the ground. Moreover, microbial activity induced CO2 production and isotopic deviation of carbon. Indeed, produced CO2 will reflect the pollutant isotopic signature. Thus, the ratio δ13C(CO2) will come closer to δ13C(hydrocarbon). BIOPHY, project supported by the French National Research Agency (ANR), proposes to use electrical methods and gas analyses to develop an operational and non-destructive method for monitoring in situ biodegradation of hydrocarbons in order to optimize soil treatment. Demonstration field is located in the South of Paris (France), where liquid fuels (gasoline and diesel) leaked from some tanks in 1997. In order to stimulate biodegradation, a trench has been dug to supply oxygen to the water table and thus stimulate aerobic metabolic bioprocesses. ER and

  16. Methodology for bioremediation monitoring of oil wastes contaminated soils by using vegetal bio indicators; Metodologia para monitoramento de biorremediacao de solos contaminados com residuos oleosos com bioindicadores vegetais

    Energy Technology Data Exchange (ETDEWEB)

    Nascimento Neto, Durval; Carvalho, Francisco Jose Pereira de Campos [Parana Univ., Curitiba, PR (Brazil). Curso de Pos-Graduacao em Ciencia do Solo]. E-mail: fjcampos@cce.ufpr.br

    1998-07-01

    This work studies the development of a methodology for the evaluation of the bioremediation status of oil waste contaminated soils, by using vegetal bioindicators for the bioremediation process monitoring, and evaluation of the environmental impacts on the contaminated areas.

  17. Redispersion of indoor surface contamination: a review

    International Nuclear Information System (INIS)

    Sansone, E.B.; Slein, M.W.

    1978-01-01

    The importance of surface contamination as a potential source of exposure to hazardous materials is discussed. Data from the literature concerning the resuspension of indoor surface contamination are presented. Reported procedures for quantitating surface contamination are compared. It is suggested that, despite its limitations, surface contamination monitoring may be useful in estimating potential risks from hazardous materials. (Auth.)

  18. Polycyclic aromatic hydrocarbons pollution effect on soil biological activity in the anthropogenic contaminated area

    Science.gov (United States)

    Batukaev, Abdulmalik; Sushkova, Svetlana; Minkina, Tatiana; Antonenko, Elena; Salamova, Anzhelika; Gimp, Alina; Deryabkina, Irina

    2017-04-01

    Polycyclic aromatic hydrocarbons (PAHs) are one of the most significant environmental contaminants with mutagenic and carcinogenic properties to all living organisms. The changes in microbial community structure in technogenic polluted soil may be used as tools for predicting and monitoring natural degradation and for search the most effective and appropriate pathways of bioremediation. The present study is aimed to research the biological activity of the soil in the emission zone of Novocherkassk Power station (NPs) (Russia) polluted by PAHs in 2015. The NPs is one of the largest thermal power stations in the south of Russia burning low-quality coal appurtenant the enterprises of I hazardous class. Monitoring plots were located on virgin or no-till fallow areas and not subject to the sanitary-protection zone of the NPs. Soil samples were taken from a depth of 0- to 20-cm, because the major part of PAHs are accumulated in the surface soil layer. The soils of the plots mainly include Chernozems Calcic (plots 1, 4, 5, 7, 9 and 10), Phaeozems Haplic (plots 3, 6, 8 and 11) Fluvisols Umbric (plots 2 and 12). In the soil of 12 monitoring plots located around NPs there were determined the main enzymes, abundance of soil bacteria and 17 priority PAHs. PAHs extraction from soil was performed by new developed ecologically clean method of subcritical water extraction without organic solvents (Sushkova et al., 2015). The level of PAHs around NPs is high at the nearest to factory monitoring plots situated at distance 1,0-1,2 km and reaches from 1600,1±14,7 up to 373,6±7,1 mkg/kg in the 20-cm soil layer. Gradually decrease of PAHs contamination is observed while increasing the distance from the NPs. The level of highmolecular PAHs (4-6 aromatic rings) exceeds the level of lowmolecular (2-3 aromatic rings) PAHs in all monitoring plots situated though the prevailing wind direction from NPs. The close correlations were found between PAHs content and biological activity parameters

  19. Requirements for internal contamination monitoring units; Anforderungen an Inkorporationsmessstellen

    Energy Technology Data Exchange (ETDEWEB)

    Werner, E. [GSF, Inst. fuer Biophysikalische Strahlenforschung, Frankfurt am Main (Germany); Beyer, D. [Forschungszentrum Juelich, Abt. ASS (Germany); Doerfel, H. [Hauptabteilung Sicherheit, Kernforschungszentrum Karlsruhe (Germany); Erlenbach, H. [Zentralstelle fuer Sicherheitstechnik NRW, Duesseldorf (Germany); Fischbach, G. [Siemens Brennelementewerk, Hanau (Germany); Henrichs, K. [Siemens AG, Muenchen (Germany); Keller, K.D. [Radiologische Universitaetsklinik, Tuebingen (Germany); Koenig, K. [Bundesamt fuer Strahlenschutz, ISH, Neuherberg (Germany); Riedel, W. [Freie Univ. Berlin, Klinikum Steglitz (Germany); Scheler, R. [Bundesamt fuer Strahlenschutz, FB Strahlenschutz, Berlin (Germany); Schieferdecker, H. [Hauptabteilung Sicherheit, Kernforschungszentrum Karlsruhe (Germany)

    1994-12-31

    For the evaluation of internal contamination by officially authorized monitoring units according to section 63 (6) of the German radiation protection ordinance, a directive will be prepared in order to define uniform requirements for the laboratories in charge of incorporation monitoring by appointment of the relevant authorities. These requirements refer to equipment, to performance of measurements, to interpretation of measured values, to quality control as well as to documentation and to delivery of results. The duties of such laboratories comprise measurements of radioactivity, evaluation of intakes of radionuclides and of the resulting internal radiation dose, but also transmission of results to the employer, to the central dose registry, and under certain circumstances to the authorities. Among the requirements to be met by the laboratory for incorporation control are a sufficient measuring efficiency, the implementation of in-house checks, and the participation in intercomparison programs. For the accomplishment of such duties the laboratory needs appropriate apparatus, rooms, facilities, and staffing. (orig.) [Deutsch] Zur Ermittlung der Koerperdosen nach Paragraph 63 StrlSchV sind fuer die gemaess Abs. 6 von der zustaendigen Behoerde zu bestimmenden Messstellen in einer Richtlinie einheitliche Anforderungen festzulegen. Diese beziehen sich auf deren Ausstattung, die Durchfuehrung der Messungen, Auswertungen und Qualitaetskontrollen sowie die Aufzeichnung und Uebermittlung der Ergebnisse. Die Aufgaben der Messstellen umfassen die Messungen der Radioaktivitaet im Koerper bzw. in Koerperausscheidungen, die Ermittlung der Zufuhr an Radionukliden sowie der daraus resultierenden Koerperdosis und die Weiterleitung der Ergebnisse an den Auftraggeber, an das zentrale Dosisregister und in bestimmten Faellen an die Behoerde. Zu den von einer Messstelle zu erfuellenden Anforderungen gehoeren eine ausreichende Messeffektivitaet, die Durchfuehrung von Eigenkontrollen

  20. Atmospheric contamination

    International Nuclear Information System (INIS)

    Gruetter, Juerg

    1997-01-01

    It is about the levels of contamination in center America, the population's perception on the problem, effects of the atmospheric contamination, effects in the environment, causes of the atmospheric contamination, possibilities to reduce the atmospheric contamination and list of Roeco Swisscontac in atmospheric contamination

  1. Fungal contamination in hospital environments.

    Science.gov (United States)

    Perdelli, F; Cristina, M L; Sartini, M; Spagnolo, A M; Dallera, M; Ottria, G; Lombardi, R; Grimaldi, M; Orlando, P

    2006-01-01

    To assess the degree of fungal contamination in hospital environments and to evaluate the ability of air conditioning systems to reduce such contamination. We monitored airborne microbial concentrations in various environments in 10 hospitals equipped with air conditioning. Sampling was performed with a portable Surface Air System impactor with replicate organism detection and counting plates containing a fungus-selective medium. The total fungal concentration was determined 72-120 hours after sampling. The genera most involved in infection were identified by macroscopic and microscopic observation. The mean concentration of airborne fungi in the set of environments examined was 19 +/- 19 colony-forming units (cfu) per cubic meter. Analysis of the fungal concentration in the different types of environments revealed different levels of contamination: the lowest mean values (12 +/- 14 cfu/m(3)) were recorded in operating theaters, and the highest (45 +/- 37 cfu/m(3)) were recorded in kitchens. Analyses revealed statistically significant differences between median values for the various environments. The fungal genus most commonly encountered was Penicillium, which, in kitchens, displayed the highest mean airborne concentration (8 +/- 2.4 cfu/m(3)). The percentage (35%) of Aspergillus documented in the wards was higher than that in any of the other environments monitored. The fungal concentrations recorded in the present study are comparable to those recorded in other studies conducted in hospital environments and are considerably lower than those seen in other indoor environments that are not air conditioned. These findings demonstrate the effectiveness of air-handling systems in reducing fungal contamination.

  2. Current Measures on Radioactive Contamination in Japan: A Policy Situation Analysis.

    Science.gov (United States)

    Gilmour, Stuart; Miyagawa, Shoji; Kasuga, Fumiko; Shibuya, Kenji

    2016-01-01

    radioactive contamination. Monitoring of radioactive materials in food products in the prefectures has been mainly conducted before shipment to restrict the distribution of radio-contaminated foods. Between March 2011 and March 2012, 133,832 tests of non-commercial and commercial products were conducted, and 1,204 tests (0.9%) were found to violate the provisional standards. Since April 2012, 278,275 tests were conducted, and 2,372 tests (0.9%) were found to violate the revised standards. MHLW assessment of representative market baskets of foodstuffs at 15 locations throughout Japan between February and March 2014 found very low estimated dietary intake of radioactive cesium (0.0007-0.019 mSv/year), as did assessments of the contents of an average day's food. Monitoring of fisheries products in coastal areas affected by the nuclear accident found very limited and declining radio-contamination of live fish outside of Fukushima prefecture. Fisheries monitoring is of limited geographical scope and covers only certain fishes. Area-specific bans on production and distribution have been effective in preventing radioactive contamination in the Japanese food market. Currently there is no major concern about radioactive cesium concentrations in retail foodstuffs in Japan, and very low levels of contamination at the production and wholesale stage. However, because the residue limits and food safety policies were revised on an ad hoc, emergency basis after the nuclear accident, the monitoring procedure needs to be reviewed based on objective and scientifically rational criteria. A transparent and objective scientific framework is needed for prioritizing foodstuffs for inspection and revising Prefecture-specific restrictions. Monitoring of fishes and other seafood products in the wild should be regularized and the information made more publicly accessible, and monitoring activities expanded to identify foodstuffs that are no longer a food safety risk. Consultation with producers and

  3. High‐resolution mass spectrometry of skin mucus for monitoring physiological impacts and contaminant biotransformation products in fathead minnows exposed to wastewater effluent

    Science.gov (United States)

    High‐resolution mass spectrometry is advantageous for monitoring physiological impacts and contaminant biotransformation products in fish exposed to complex wastewater effluent. We evaluated this technique using skin mucus from male and female fathead minnows (Pimephales pr...

  4. Use of biological activities to monitor the removal of fuel contaminants - perspective for monitoring hydrocarbon contamination: A review

    CSIR Research Space (South Africa)

    Maila, MP

    2005-01-01

    Full Text Available Soil biological activities are vital for the restoration of soil contaminated with hydrocarbons. Their role includes the biotransformation of petroleum compounds into harmless compounds. In this paper, the use of biological activities as potential...

  5. Climate change increases deoxynivalenol contamination of wheat in north-western Europe

    DEFF Research Database (Denmark)

    van der Fels-Klerx, H J; Olesen, Jørgen E; Madsen, M S

    2012-01-01

    will be earlier in the season because of climate change effects, about 1 to 2 weeks. Deoxynivalenol contamination was found to increase in most of the study region, with an increase of the original concentrations by up to 3 times. The study results may inform governmental and industrial risk managers to underpin...... decision-making and planning processes in north-western Europe. On the local level, deoxynivalenol contamination should be closely monitored to pick out wheat batches with excess levels at the right time. Using predictive models on a more local scale could be helpful to assist other monitoring measures...... to safeguard food safety in the wheat supply chain....

  6. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 1, Operations

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The Monitoring division is primarily responsible for the coordination and direction of: Aerial measurements to delineate the footprint of radioactive contaminants that have been released into the environment. Monitoring of radiation levels in the environment; Sampling to determine the extent of contaminant deposition in soil, water, air and on vegetation; Preliminary field analyses to quantify soil concentrations or depositions; and Environmental and personal dosimetry for FRMAC field personnel, during a Consequence Management Response Team (CMRT) and Federal Radiological Monitoring and Assessment Center (FRMAC) response. Monitoring and sampling techniques used during CM/FRMAC operations are specifically selected for use during radiological emergencies where large numbers of measurements and samples must be acquired, analyzed, and interpreted in the shortest amount of time possible. In addition, techniques and procedures are flexible so that they can be used during a variety of different scenarios; e.g., accidents involving releases from nuclear reactors, contamination by nuclear waste, nuclear weapon accidents, space vehicle reentries, or contamination from a radiological dispersal device. The Monitoring division also provides technicians to support specific Health and Safety Division activities including: The operation of the Hotline; FRMAC facility surveys; Assistance with Health and Safety at Check Points; and Assistance at population assembly areas which require support from the FRMAC. This volume covers deployment activities, initial FRMAC activities, development and implementation of the monitoring and assessment plan, the briefing of field teams, and the transfer of FRMAC to the EPA.

  7. Contamination control engineering design guidelines for the aerospace community

    Science.gov (United States)

    Tribble, A. C. (Principal Investigator); Boyadjian, B.; Davis, J.; Haffner, J.; McCullough, E.

    1996-01-01

    Thermal control surfaces, solar arrays, and optical devices may be adversely affected by a small quantity of molecular and/or particulate contamination. What is rarely discussed is how one: (1) quantifies the level of contamination that must be maintained in order for the system to function properly, and (2) enforces contamination control to ensure compliance with requirements. This document is designed to address these specific issues and is intended to serve as a handbook on contamination control for the reader, illustrating process and methodology while providing direction to more detailed references when needed. The effects of molecular contamination on reflecting and transmitting surfaces are examined and quantified in accordance with MIL STD 1246C. The generation, transportation, and deposition of molecular contamination is reviewed and specific examples are worked to illustrate the process a design engineer can use to estimate end of life cleanliness levels required by solar arrays, thermal control surfaces, and optical surfaces. A similar process is used to describe the effect of particulate contamination as related to percent area coverage (PAC) and bi-directional reflectance distribution function (BRDF). Relationships between PAC and surface cleanliness, which include the effects of submicron sized particles, are developed and BRDF is related to specific sensor design parameters such as Point Source Transmittance (PST). The pros and cons of various methods of preventing, monitoring, and cleaning surfaces are examined and discussed.

  8. Variation of heavy metals within and among feathers of birds of prey: effects of molt and external contamination

    Energy Technology Data Exchange (ETDEWEB)

    Dauwe, T.; Bervoets, L.; Pinxten, R.; Blust, R.; Eens, M

    2003-08-01

    Concentrations of many heavy metals in feathers, except Hg, did not reflect the molting sequence, suggesting external contamination. - In this study we examined the effect of external contamination on the heavy metal (Ag, Al, As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb and Zn) concentration in feathers. We compared the heavy metal content among the 10 primary wing feathers of sparrowhawks (Accipiter nisus), little owls (Athene nocta) and barn owls (Tyto alba) and the variation within the outermost tail feather of sparrowhawks and tawny owls (Strix aluco). The concentration of Hg was significantly higher in feathers molted first, suggesting that levels in feathers reflect levels in the blood during formation. For some other elements (Al, Co, Ni, Pb, Zn) on the other hand, there are strong indications that external contamination may have an important impact on the levels detected in the feathers. This should be taken into account in future monitoring studies.

  9. [Decorporation agents for internal radioactive contamination].

    Science.gov (United States)

    Ohmachi, Yasushi

    2015-01-01

    When radionuclides are accidentally ingested or inhaled, blood circulation or tissue/organ deposition of the radionuclides causes systemic or local radiation effects. In such cases, decorporation therapy is used to reduce the health risks due to their intake. Decorporation therapy includes reduction and/or inhibition of absorption from the gastrointestinal tract, isotopic dilution, and the use of diuretics, adsorbents, and chelating agents. For example, penicillamine is recommended as a chelating agent for copper contamination, and diethylene triamine pentaacetic acid is approved for the treatment of internal contamination with plutonium. During chelation therapy, the removal effect of the drugs should be monitored using a whole-body counter and/or bioassay. Some authorities, such as the National Council on Radiation Protection and Measurements and International Atomic Energy Agency, have reported recommended decorporation agents for each radionuclide. However, few drugs are approved by the US Food and Drug Administration, and many are off-label-use agents. Because many decontamination agents are drugs that have been available for a long time and have limited efficacy, the development of new, higher-efficacy drugs has been carried out mainly in the USA and France. In this article, in addition to an outline of decorporation agents for internal radioactive contamination, an outline of our research on decorporation agents for actinide (uranium and plutonium) contamination and for radio-cesium contamination is also presented.

  10. Effects of biochar and greenwaste compost amendments on mobility, bioavailability and toxicity of inorganic and organic contaminants in a multi-element polluted soil

    Energy Technology Data Exchange (ETDEWEB)

    Beesley, Luke, E-mail: L.Beesley@2007.ljmu.ac.u [Faculty of Science, Liverpool John Moores University, Liverpool L3 3AF (United Kingdom); Moreno-Jimenez, Eduardo [Departamento de Quimica Agricola, Universidad Autonoma de Madrid, 28049 Madrid (Spain); Gomez-Eyles, Jose L. [University of Reading, Department of Soil Science, Whiteknights, Reading RG6 6DW (United Kingdom)

    2010-06-15

    Applying amendments to multi-element contaminated soils can have contradictory effects on the mobility, bioavailability and toxicity of specific elements, depending on the amendment. Trace elements and PAHs were monitored in a contaminated soil amended with biochar and greenwaste compost over 60 days field exposure, after which phytotoxicity was assessed by a simple bio-indicator test. Copper and As concentrations in soil pore water increased more than 30 fold after adding both amendments, associated with significant increases in dissolved organic carbon and pH, whereas Zn and Cd significantly decreased. Biochar was most effective, resulting in a 10 fold decrease of Cd in pore water and a resultant reduction in phytotoxicity. Concentrations of PAHs were also reduced by biochar, with greater than 50% decreases of the heavier, more toxicologically relevant PAHs. The results highlight the potential of biochar for contaminated land remediation. - Biochar was more effective than greenwaste compost at reducing bioavailable fractions of phytotoxic Cd and Zn as well as the heavier, more toxicologically relevant PAHs.

  11. Hybrid monitoring of environmental radioactivity as a perspective approach to rapid control and prediction of environmental contamination due to NPP wastes and effluents

    International Nuclear Information System (INIS)

    Eremeev, I.S.; Eremenko, V.A.; Zhernov, V.S.; Makarov, Yu.A.; Matveev, V.V.; Ryzhov, N.V.; Ryazanov, V.V.; Skatkin, V.M.

    1985-01-01

    Conseptucal model of the system of hybride monitoring of environmental radioactivity due to NPP wastes and effluents is proposed. The model a combination of measuring and simulating monitoring, provides correlation of methods and aims of simulation of environmental contamination spread methods and means of monitoring of its factual distribution in space, methods of separation of technogeneous signals from natural radiation background and provision of the given degree of reliability of results of information processing, in particular periodic coorection, model adaptation according to the factual measurement data

  12. Monitoring of Fasciola Species Contamination in Water Dropwort by cox1 Mitochondrial and ITS-2 rDNA Sequencing Analysis.

    Science.gov (United States)

    Choi, In-Wook; Kim, Hwang-Yong; Quan, Juan-Hua; Ryu, Jae-Gee; Sun, Rubing; Lee, Young-Ha

    2015-10-01

    Fascioliasis, a food-borne trematode zoonosis, is a disease primarily in cattle and sheep and occasionally in humans. Water dropwort (Oenanthe javanica), an aquatic perennial herb, is a common second intermediate host of Fasciola, and the fresh stems and leaves are widely used as a seasoning in the Korean diet. However, no information regarding Fasciola species contamination in water dropwort is available. Here, we collected 500 samples of water dropwort in 3 areas in Korea during February and March 2015, and the water dropwort contamination of Fasciola species was monitored by DNA sequencing analysis of the Fasciola hepatica and Fasciola gigantica specific mitochondrial cytochrome c oxidase subunit 1 (cox1) and nuclear ribosomal internal transcribed spacer 2 (ITS-2). Among the 500 samples assessed, the presence of F. hepatica cox1 and 1TS-2 markers were detected in 2 samples, and F. hepatica contamination was confirmed by sequencing analysis. The nucleotide sequences of cox1 PCR products from the 2 F. hepatica-contaminated samples were 96.5% identical to the F. hepatica cox1 sequences in GenBank, whereas F. gigantica cox1 sequences were 46.8% similar with the sequence detected from the cox1 positive samples. However, F. gigantica cox1 and ITS-2 markers were not detected by PCR in the 500 samples of water dropwort. Collectively, in this survey of the water dropwort contamination with Fasciola species, very low prevalence of F. hepatica contamination was detected in the samples.

  13. Analysis of food contaminants

    National Research Council Canada - National Science Library

    Gilbert, John

    1984-01-01

    ... quantification methods used in the analysis of mycotoxins in foods - Confirmation and quantification of trace organic food contaminants by mass spectrometry-selected ion monitoring - Chemiluminescence...

  14. Soil contamination in south Backa region of Serbia with dangerous and harmful substances

    Directory of Open Access Journals (Sweden)

    Maksimović Livija

    2012-01-01

    Full Text Available Soil samples in disturbed state were taken in order to control fertility and monitor contents of harmful and hazardous substances in Vojvodina soils and possibilities of soil degradation in general. Moderately contaminated soils were selected for examination. Microbial activity in contaminated soil and the impact of harmful and hazardous substances (pesticides on soil microorganisms were observed and most resistant microorganisms were isolated. Vegetation experiments were organized to study the effect of chelating agents EDTA and EDDS on copper adoption and translocation in rapeseed and sunflower. Importance of some ions in the complexation of copper chelators and their undesirable effects on copper uptake were established. Field trials were organized to study the effect of hydrogel on water uptakes by plants, increase in rate and the increase in rate of removal of hazardous and harmful substances from soil solution. At all phases of the project, we monitored the effectiveness of soil bioremediation soils by means of the application of chelating agents, stimulative preparations such as hydrogel and certain microorganisms. It effectiveness was measured in terms of plant growth rate and intensity in removal of hazardous and harmful substances from contaminated soil.

  15. Effects of processing techniques on the radioactive contamination of food

    International Nuclear Information System (INIS)

    Bovard, P.; Delmas, J.; Grauby, A.

    Following contamination of cultures of rice, grapes and various vegetables by 90 Sr and 137 Cs, the effect of processing and cooking techniques on the contamination of the food-stuff was investigated [fr

  16. Contaminants as viral cofactors: assessing indirect population effects

    Science.gov (United States)

    Springman, Katherine R.; Kurath, Gael; Anderson, James J.; Emlen, John M.

    2005-01-01

    Current toxicological methods often miss contaminant effects, particularly when immune suppression is involved. The failure to recognize and evaluate indirect and sublethal effects severely limits the applicability of those methods at the population level. In this study, the Vitality model is used to evaluate the population level effects of a contaminant exerting only indirect, sublethal effects at the individual level. Juvenile rainbow trout (Oncorhynchus mykiss) were injected with 2.5 or 10.0 mg/kg doses of the model CYP1A inducer, β-naphthoflavone (BNF) as a pre-stressor, then exposed to a challenge dose of 102 or 104 pfu/fish of infectious hematopoietic necrosis virus (IHNV), an important viral pathogen of salmonids in North America. At the end of the 28-d challenge, the mortality data were processed according to the Vitality model which indicated that the correlation between the average rate of vitality loss and the pre-stressor dose was strong:R2 = 0.9944. Average time to death and cumulative mortality were dependent on the BNF dose, while no significant difference between the two viral dosages was shown, implying that the history of the organism at the time of stressor exposure is an important factor in determining the virulence or toxicity of the stressor. The conceptual framework of this model permits a smoother transfer of results to a more complex stratum, namely the population level, which allows the immunosuppressive results generated by doses of a CYP1A inducer that more accurately represent the effects elicited by environmentally-relevant contaminant concentrations to be extrapolated to target populations. The indirect effects of other environmental contaminants with similar biotransformation pathways, such as polycyclic aromatic hydrocarbons (PAH), could be assessed and quantified with this model and the results applied to a more complex biological hierarchy.

  17. Bioclogging Effects Relevant to In-Situ Bioremediation of Organic Contaminants

    Science.gov (United States)

    Bielefeldt, A. R.; Illangasekare, T.

    2002-05-01

    This presentation will summarize 5 years of laboratory experiments investigating the effects of biodegradation of organic contaminants on the hydrodynamic properties of saturated sand due to biomass accumulation. The contaminants studied included naphthalene, decane, diesel fuel, propylene glycol, and aircraft de-icing fluid (ADF). Most of the experiments were conducted in columns (~6 cm dia x 15 cm L). A wide range of environmental conditions were simulated including low to high organic loading (1.2 to 38,000 mg C/kg dry sand/d), various nutrient concentrations (C:N 3:1 to 5424:1), seepage velocity (0.5-11 m/d), and sand size (average diameter 0.19, 0.32, 0.49 mm). Changes in the hydraulic conductivity and dispersivity of the media over time and the biomass distribution in the sand at the end of the experiments were measured. In general, the hydraulic conductivity in the columns declined over time until a steady-state minimum was reached when the new biogrowth was balanced by endogenous decay and shear stress losses from the system. The minimum conductivity was generally 2 to 4 orders of magnitude below that of the clean sand. Dispersivity was evaluated using bromide tracer tests and monitoring the break-through curves. Dispersivity after biomass growth was always higher than that of the clean sand (up to 10x), but trends over time did not always consistently increase. Under selected conditions the dispersivity initially increased and then decreased, although never achieving a level below that of the clean sand. Final biomass concentrations in the sand at steady state ranged from 0.1 to 10 mg dry weight/g dry sand. In some experiments the biomass was evenly distributed through the sand while in others significantly more biomass was present at the column inlet. Some experiments were also conducted in larger 2-D tanks (122 cm L x 46 cm H x 6 cm W) which allowed the groundwater flow to route around local areas of bioclogging as would be likely to occur in subsurface

  18. Remote Sensing Combined with Field Spectroscopy for the Detection and Monitoring of Heavy Metal Contamination from Informal E-waste Recycling

    Science.gov (United States)

    Friedlander, L. R.; Garb, Y.

    2017-12-01

    Electronic waste (e-waste) is one of today's fastest growing waste streams. Made up of discarded electronics, e-waste disposal is complex. However, e-waste also provides economic opportunity through the processing and extraction of precious metals. Sometimes referred to as "urban mining," this recycling operates informally or illegally and is characterized by dangerous practices such as, open-pit burning, acid leaching, and burning of low value wastes. Poorly controlled e-waste recycling releases dangerous contaminants, especially heavy metals, directly to the surface environment where they can infiltrate water resources and spread through precipitation events. Despite growing recognition of the prevalence of unregulated e-waste processing, systematic data on the extent and persistence of the released contamination is still limited. In general, contamination is established through techniques that provide only a snapshot in time and in a limited geographic area. Here we present preliminary results from attempts to combine field, laboratory, and remote sensing studies toward a systematic remote sensing methodology for e-waste contamination detection and monitoring. The ongoing work utilizes a tragic "natural experiment," in which over 500 e-waste burn sites were active over more than a decade in a variety of agricultural, residential, and natural contexts. We have collected over 100 soil samples for which we have both XRF and ICP-AES measurements showing soil Pb concentrations as high as 14000 ppm. We have also collected 480 in-situ reflectance spectra with corresponding soil samples over 4 field transects of areas with long-term burn activity. The most heavily contaminated samples come from within the burn sites and are made up of ash. Field spectra of these samples reflect their dark color with low overall reflectance and shallow spectral features. These spectra are challenging to use for image classification due to their similarity with other low-reflectance parts

  19. Contamination monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Alamares, A L [Philippine Nuclear Research Inst., Diliman, Quezon City (Philippines)

    1997-06-01

    By virture of Republic Act 2067, as amended the Philippine Atomic Energy Commission (PAEC), now renamed Philippine Nuclear Research Institute (PNRI) is the government agency charged with the regulations and control of radioactive materials in the Philippines. The protection against the hazards of non-ionizing radiation is being monitored by the Radiological Health Service (RHS) of the Department of Health pursuant to the provision of Presidental Decree 480. The RHS issues licenses for possession, handling, and use of x-ray machines and equipment, both industrial and medical, and provide radiation protection training to x-ray technologists and technicians. As part of its regulatory function, the PNRI is charged with the responsibility of assuring that the radiation workers and the public are protected from the hazards associated with the possession, handling, production, manufacturing, and the use of radioactive materials and atomic energy facilities in the Philippines. The protection of radiation workers from the hazards of ionizing radiation has always been a primary concern of PNRI and by limiting the exposure of radiation workers, the risk to population is kept to within acceptable level. In this paper, the following items are described: radiation protection program, radiation protection services, radiation control, and problems encountered/recommendation. (G.K.)

  20. Exposure and effects assessment of persistent organohalogen contaminants in arctic wildlife and fish.

    Science.gov (United States)

    Letcher, Robert J; Bustnes, Jan Ove; Dietz, Rune; Jenssen, Bjørn M; Jørgensen, Even H; Sonne, Christian; Verreault, Jonathan; Vijayan, Mathilakath M; Gabrielsen, Geir W

    2010-07-01

    Persistent organic pollutants (POPs) encompass an array of anthropogenic organic and elemental substances and their degradation and metabolic byproducts that have been found in the tissues of exposed animals, especially POPs categorized as organohalogen contaminants (OHCs). OHCs have been of concern in the circumpolar arctic for decades. For example, as a consequence of bioaccumulation and in some cases biomagnification of legacy (e.g., chlorinated PCBs, DDTs and CHLs) and emerging (e.g., brominated flame retardants (BFRs) and in particular polybrominated diphenyl ethers (PBDEs) and perfluorinated compounds (PFCs) including perfluorooctane sulfonate (PFOS) and perfluorooctanic acid (PFOA) found in Arctic biota and humans. Of high concern are the potential biological effects of these contaminants in exposed Arctic wildlife and fish. As concluded in the last review in 2004 for the Arctic Monitoring and Assessment Program (AMAP) on the effects of POPs in Arctic wildlife, prior to 1997, biological effects data were minimal and insufficient at any level of biological organization. The present review summarizes recent studies on biological effects in relation to OHC exposure, and attempts to assess known tissue/body compartment concentration data in the context of possible threshold levels of effects to evaluate the risks. This review concentrates mainly on post-2002, new OHC effects data in Arctic wildlife and fish, and is largely based on recently available effects data for populations of several top trophic level species, including seabirds (e.g., glaucous gull (Larus hyperboreus)), polar bears (Ursus maritimus), polar (Arctic) fox (Vulpes lagopus), and Arctic charr (Salvelinus alpinus), as well as semi-captive studies on sled dogs (Canis familiaris). Regardless, there remains a dearth of data on true contaminant exposure, cause-effect relationships with respect to these contaminant exposures in Arctic wildlife and fish. Indications of exposure effects are largely

  1. Internal contamination: what challenges for tomorrow? Proceedings of the Research and Health Section technical day

    International Nuclear Information System (INIS)

    Berard, Philippe; Lecoix, Geraldine; Menetrier, Florence; Menetrier, Florence; Leiterer, Alexandra; Gremy, Olivier; Mougnard, Philippe; Gonin, Michele; Paquet, Francois; Davesne, Estelle; Bertho, Jean-Marc; Metivier, Henri; Abergel, Rebecca

    2015-10-01

    The Research and Health Section of the French Society of Radiation Protection (SFRP) organized a technical meeting on the radiation protection aspects of dismantlement, from the dismantling work to the risk, the measurement of body contamination, the potentially harmful health effects, the available medical treatments, the actual needs and the developments in progress. This document brings together the abstracts and the presentations (slides) of the different talks given at the meeting: 1 - Situation: what radionuclides, what situations? (Philippe BERARD, CEA); 2 - Dismantling workplace experience feedback with internal contamination hazard (Philippe MOUGNARD, AREVA); 3 - Experience feedback on internal exposure monitoring at power plants in France (Michele GONIN, EDF); 4 - Evolution of routine and intervention measurement methods (Geraldine LECOIX, CEA); 5 - Evolution of radiation dose calculation models (Francois PAQUET, IRSN); 6 - Taking uncertainties into account in internal contamination monitoring protocols (Estelle DAVESNE, IRSN); 7 - Radionuclides behaviour and effects in men (Florence MENETRIER, CEA); 8 - The plutonium case (Henri METIVIER, SFRP); 9 - Cesium-137 and internal contamination: status and perspectives (Jean-Marc BERTHO, IRSN); 10 - Iodine and thyroid (Florence MENETRIER, CEA); 11 - Actual treatments and research pathways (Alexandra LEITERER, CEA); 12 - Radionuclide contamination treatment: new developments in the US (Rebecca ABERGEL, Berkeley USA); 13 - Internal contaminations treatment: French recent effort for its improvement (Olivier GREMY, CEA)

  2. Rulison Monitoring Plan

    Energy Technology Data Exchange (ETDEWEB)

    None

    2010-07-01

    radionuclides created by the test are unlikely to migrate appreciable distances (hundreds of feet) from the detonation zone (Cooper et al. 2007, 2009). The Monitoring Plan was developed to provide a cautious and comprehensive approach for detecting any potential contaminant migration from the Rulison test site. It also provides an independent confirmation of results from the industry sampling and analysis plan while effectively increasing the sampling frequency of wells near the site.

  3. Characterisation of contamination migration in the workplace

    International Nuclear Information System (INIS)

    Boulaud, D.; Laborde, J.C.; Pourprix, M.

    1994-01-01

    The Institute for Nuclear Safety and Protection (IPSN) has developed a procedure for characterising airborne contamination between processes and the workplace in nuclear facilities. It was initially intended to use this process to validate operator choices concerning the monitoring of indoor air contamination (personnel monitoring, and environmental detection at fixed locations), but also to optimise the fundamental parameters which have a more or less direct influence on potential exposure of staff in the workplace (at the same time optimising the contamination source, close confinement, process ventilation and general ventilation). In practice, the methods used to obtain these expert appraisals were usually based on experiments carried out in situ: (i) characterisation of aerosol contamination by accurate measurement of the nature, concentration and particle size distribution at various locations; (ii) characterisation of the migration of contamination by precise measurement involving gas and/or particle tracing techniques. In parallel with these experiments, a considerable effort was made to develop and qualify computer codes capable of predicting or estimating the migration of contamination through complex ventilated areas, by means of both fluid mechanics and aerosol science. (Author)

  4. Response of PCB contamination in stream fish to abatement actions at an industrial site

    International Nuclear Information System (INIS)

    Southworth, G.R.; Peterson, M.J.; McCarthy, J.F.; Milne, G.

    1995-01-01

    The Paducah Gaseous Diffusion Plant (PGDP) in Paducah, Kentucky, used large quantities of PCBs in equipment associated with the great electric power requirements of isotopic enrichment of uranium. Historic losses of PCBs in the 1950s and 1960s have left a legacy of contamination at the site. A biological monitoring program implemented in 1987 found PCBs in PGDP effluents and in fish downstream from facility discharges. As a consequence, a fish consumption advisory was posted on Little Bayou Creek by the Commonwealth of Kentucky in 1987, and regulatory discharge limits for PCBs at PGDP were reduced. Monitoring at multiple locations in receiving streams indicated that PGDP discharges were more important than in stream sediment contamination as sources of PCBs to fish. Environmental management and compliance staff at PGDP led an effort to reduce PCB discharges and monitor the effects of those actions. The active discharge of uncontaminated process water to historically PCB-contaminated drainage systems was found to mobilize PCBs into KPDES (Clean Water Act) regulated effluents. Efforts to locate PCB sources within the plant, coupled with improvements in management practices and remedial actions, appear to have been successful in reducing PCB discharges from these sources. Actions included emplacing passive monitors in the plant drainage system to identify this as a chronic source, and consolidating and re-routing effluents to minimize flow through PCB-contaminated channels. As a consequence, PCB contamination in fish in small streams receiving plant discharges decreased 75% over from 1992--1995

  5. Atmospheric air contamination monitoring. Monitoring station ASS-500, GIG Katowice

    International Nuclear Information System (INIS)

    Michalik, B.

    1993-01-01

    The results obtained during the period of 1991-1993 in monitoring station ASS-500 working in Katowice have been presented. The concentration of 137 Cs, 226 Ra, 40 K, 7 Be and dustiness in atmospheric air have been shown. Some proposals about the modifications of monitoring station ASS-500 have been introduced. 3 figs, 5 tabs

  6. Aflatoxin B1 contamination in feed from Puglia and Basilicata regions (Italy): 5 years monitoring data.

    Science.gov (United States)

    Vita, V; Clausi, M T; Franchino, C; De Pace, R

    2016-11-01

    During a 5-year period from 2010 to 2014, n = 919 samples of feed and raw materials were analyzed for aflatoxin B 1 (AFB 1 ) contamination using accredited ELISA screening methods. Only 0.76 % of these samples were non-compliant with maximum levels set by the European Union Regulation 32/2002. Non-compliant samples were mainly from the province of Bari (n = 3 samples, mean AFB 1 value 7.03 μg/kg), although the highest AFB 1 levels were found in two samples from the provinces of Foggia and Brindisi, at 32.6 ± 3.6 μg/kg and 31.0 ± 4.0 μg/kg, respectively. Mean AFB 1 levels in samples contaminated but compliant with the limits ranged from 1.4 to 2.2 μg/kg. Considering the great importance of climate conditions in mycotoxins production, during crops production and during the critical phases of materials storage and/or transport, to better understand the variability in contamination levels, the analytical results were reviewed in term of temperature and relative environmental humidity in the sampling areas. Correlations between aflatoxin B 1 levels in feed and these climate factors might explain seasonal and annual variations in contamination levels. The data from the present study provide useful suggestions for the organization of targeted monitoring plans and the protection of consumers, as well as for improvement in the quality standards of zootechnological activities and feed industry.

  7. Hanford Site ground-water monitoring for 1995

    International Nuclear Information System (INIS)

    Dresel, P.E.; Rieger, J.T.; Webber, W.D.; Thorne, P.D.; Gillespie, B.M.; Luttrell, S.P.; Wurstner, S.K.; Liikala, T.L.

    1996-08-01

    This report presents the results of the Groundwater Surveillance Project monitoring for calendar year 1995 on the Hanford Site, Washington. Hanford Site operations from 1943 onward produced large quantities of radiological and chemical waste that impacted groundwater quality on the site. Monitoring of water levels and groundwater chemistry is performed to track the extent of contamination, to note trends in contaminant concentrations,a nd to identify emerging groundwater quality problems. Data from other monitoring and characterization programs were incorporated to provide an integrated assessment of onsite groundwater quality. A three- dimensional, numerical, groundwater model is being developed to improve predictions of contaminant transport. The existing two- dimensional model was applied to predict contaminant flow paths and the impact of changes on site conditions. These activities were supported by limited hydrogeologic characterization. Water level monitoring was performed to evaluate groundwater flow directions, to track changes in water levels, and to relate such changes to evolving disposal practices. Radiological monitoring results indicated that many radioactive contaminants were above US Environmental Protection Agency or State of Washington drinking water standards at the Hanford Site. Nitrate, fluoride, chromium, cyanide, carbon tetrachloride, chloroform, trichloroethylene, and cis-1,2-dichloroethylene were present in groundwater samples at levels above their US EPA or State of Washington maximum contaminant levels

  8. Improvement of personalized Monte Carlo-aided direct internal contamination monitoring: optimization of calculation times and measurement methodology for the establishment of activity distribution

    International Nuclear Information System (INIS)

    Farah, Jad

    2011-01-01

    To optimize the monitoring of female workers using in vivo spectrometry measurements, it is necessary to correct the typical calibration coefficients obtained with the Livermore male physical phantom. To do so, numerical calibrations based on the use of Monte Carlo simulations combined with anthropomorphic 3D phantoms were used. Such computational calibrations require on the one hand the development of representative female phantoms of different size and morphologies and on the other hand rapid and reliable Monte Carlo calculations. A library of female torso models was hence developed by fitting the weight of internal organs and breasts according to the body height and to relevant plastic surgery recommendations. This library was next used to realize a numerical calibration of the AREVA NC La Hague in vivo counting installation. Moreover, the morphology-induced counting efficiency variations with energy were put into equation and recommendations were given to correct the typical calibration coefficients for any monitored female worker as a function of body height and breast size. Meanwhile, variance reduction techniques and geometry simplification operations were considered to accelerate simulations. Furthermore, to determine the activity mapping in the case of complex contaminations, a method that combines Monte Carlo simulations with in vivo measurements was developed. This method consists of realizing several spectrometry measurements with different detector positioning. Next, the contribution of each contaminated organ to the count is assessed from Monte Carlo calculations. The in vivo measurements realized at LEDI, CIEMAT and KIT have demonstrated the effectiveness of the method and highlighted the valuable contribution of Monte Carlo simulations for a more detailed analysis of spectrometry measurements. Thus, a more precise estimate of the activity distribution is given in the case of an internal contamination. (author)

  9. Current Measures on Radioactive Contamination in Japan: A Policy Situation Analysis.

    Directory of Open Access Journals (Sweden)

    Stuart Gilmour

    areas at risk of radioactive contamination. Monitoring of radioactive materials in food products in the prefectures has been mainly conducted before shipment to restrict the distribution of radio-contaminated foods. Between March 2011 and March 2012, 133,832 tests of non-commercial and commercial products were conducted, and 1,204 tests (0.9% were found to violate the provisional standards. Since April 2012, 278,275 tests were conducted, and 2,372 tests (0.9% were found to violate the revised standards. MHLW assessment of representative market baskets of foodstuffs at 15 locations throughout Japan between February and March 2014 found very low estimated dietary intake of radioactive cesium (0.0007-0.019 mSv/year, as did assessments of the contents of an average day's food. Monitoring of fisheries products in coastal areas affected by the nuclear accident found very limited and declining radio-contamination of live fish outside of Fukushima prefecture. Fisheries monitoring is of limited geographical scope and covers only certain fishes.Area-specific bans on production and distribution have been effective in preventing radioactive contamination in the Japanese food market. Currently there is no major concern about radioactive cesium concentrations in retail foodstuffs in Japan, and very low levels of contamination at the production and wholesale stage. However, because the residue limits and food safety policies were revised on an ad hoc, emergency basis after the nuclear accident, the monitoring procedure needs to be reviewed based on objective and scientifically rational criteria. A transparent and objective scientific framework is needed for prioritizing foodstuffs for inspection and revising Prefecture-specific restrictions. Monitoring of fishes and other seafood products in the wild should be regularized and the information made more publicly accessible, and monitoring activities expanded to identify foodstuffs that are no longer a food safety risk. Consultation with

  10. Concentrations of elements in fish fillets, fish muscle plugs, and crayfish from the 2011 Missouri Department of Conservation general contaminant monitoring program

    Science.gov (United States)

    May, Thomas W.; Walther, Michael J.; Brumbaugh, William G.; McKee, Michael J.

    2013-01-01

    This report presents the results of a contaminant monitoring survey conducted annually by the Missouri Department of Conservation to examine the levels of selected elemental contaminants in fish fillets, fish muscle plugs, and crayfish. Fillet samples of yellow bullhead (Ameiurus natalis), golden redhorse (Moxostoma erythrurum), longear sunfish (Lepomis megalotis), and channel catfish (Ictalurus punctatus) were collected from six sites as part of the Missouri Department of Conservation’s Fish Contaminant Monitoring Program. Fish dorsal muscle plugs were collected from largemouth bass (Micropterus salmoides) at eight of the sites, and crayfish from two sites. Following preparation and analysis of the samples, highlights of the data were as follows: cadmium and lead residues were most elevated in crayfish tissue samples from the Big River at Cherokee Landing, with 1 to 8 micrograms per gram dry weight and 22 to 45 micrograms per gram dry weight, respectively. Some dorsal muscle plugs from largemouth bass collected from Clearwater Lake, Lake St. Louis, Noblett Lake, Hazel Creek Lake, and Harrison County Lake contained mercury residues (1.7 to 4.7 micrograms per gram dry weight) that exceeded the U.S. Environmental Protection Agency Water Quality Criterion of 1.5 micrograms per gram dry weight of fish tissue (equivalent to 0.30 micrograms per gram wet weight).

  11. Thyroid monitoring for residents of disaster-affected and neighboring areas

    International Nuclear Information System (INIS)

    Ito, Shigeki

    2014-01-01

    The devastating environmental contamination caused by the nuclear disaster at the Fukushima Daiichi Nuclear Power Station of The Tokyo Electric Power Company is exposing the residents of the disaster-affected areas to health risks attributable to radiation exposure, and fear of the development of 131 I-induced thyroid cancer, which is a stochastic effect of radiation and is particularly high. As part of the response to nuclear disasters by the government of the municipality where the nuclear power station is located and in operation and by the governments of neighboring municipalities, it is necessary to conduct thyroid monitoring for the purpose of alleviating the fears of residents of the disaster-affected areas as well as those living in the contaminated, even if only slightly, neighboring areas (local residents). This health monitoring needs to be implemented without delay in the case of a disaster along with dissemination of a portable type thyroid monitoring system available at evacuation centers, etc. for assessing thyroid exposure doses. The establishment of a system for developing personnel ready to perform monitoring is also essential. Assessing thyroid exposure doses is indispensable as a means of assuring local residents not only of safety but also of security from the risks of radiation. To date, contamination has not been detected in people, except for residents contaminated by a large amount of iodine, by employing the mobile type of thyroid monitoring system. However, when local residents seeking security desire thyroid monitoring, it is preferable that a portable type simplified thyroid monitoring system be used as a means of ensuring security against radiation. (author)

  12. Effects of different remediation treatments on crude oil contaminated saline soil.

    Science.gov (United States)

    Gao, Yong-Chao; Guo, Shu-Hai; Wang, Jia-Ning; Li, Dan; Wang, Hui; Zeng, De-Hui

    2014-12-01

    Remediation of the petroleum contaminated soil is essential to maintain the sustainable development of soil ecosystem. Bioremediation using microorganisms and plants is a promising method for the degradation of crude oil contaminants. The effects of different remediation treatments, including nitrogen addition, Suaeda salsa planting, and arbuscular mycorrhiza (AM) fungi inoculation individually or combined, on crude oil contaminated saline soil were assessed using a microcosm experiment. The results showed that different remediation treatments significantly affected the physicochemical properties, oil contaminant degradation and bacterial community structure of the oil contaminated saline soil. Nitrogen addition stimulated the degradation of total petroleum hydrocarbon significantly at the initial 30d of remediation. Coupling of different remediation techniques was more effective in degrading crude oil contaminants. Applications of nitrogen, AM fungi and their combination enhanced the phytoremediation efficiency of S. salsa significantly. The main bacterial community composition in the crude oil contaminated saline soil shifted with the remediation processes. γ-Proteobacteria, β-Proteobacteria, and Actinobacteria were the pioneer oil-degraders at the initial stage, and Firmicutes were considered to be able to degrade the recalcitrant components at the later stage. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Surveillance for previously unmonitored organic contaminants in the San Francisco Estuary.

    Science.gov (United States)

    Oros, Daniel R; Jarman, Walter M; Lowe, Theresa; David, Nicole; Lowe, Sarah; Davis, Jay A

    2003-09-01

    The San Francisco Estuary Regional Monitoring Program initiated surveillance monitoring to identify previously unmonitored synthetic organic contaminants in the San Francisco Estuary. Organic extracts of water samples were analyzed using gas chromatography-mass spectrometry in full scan mode. The major contaminant classes identified in the samples were fire retardants, pesticides, personal care product ingredients, and plasticizers. Evidence from the literature suggests that some of these contaminants can persist in the environment, induce toxicity, and accumulate in marine biota and in higher food chain consumers. The major sources of these contaminants into the marine environment are the discharge of municipal and industrial wastewater effluents, urban stormwater, and agricultural runoff. As a proactive effort, it is suggested that surveillance studies be used routinely in monitoring programs to identify and prevent potential problem contaminants from harming the marine environment.

  14. Technologies for remediating radioactively contaminated land

    International Nuclear Information System (INIS)

    Pearl, M.

    2000-01-01

    This paper gives an overview of technologies that can be used for the remediation of radioactively contaminated ground. There are a wide variety of techniques available -most have established track records for contaminated ground, though in general many are only just being adapted to use for radioactively contaminated ground. 1) Remediation techniques for radioactively contaminated ground involve either removal of the contamination and transfer to a controlled/contained facility such as the national LLW repository at Drigg, or 2) immobilization, solidification and stabilization of the contamination where the physical nature of the soil is changed, or an 'agent' is added to the soil, to reduce the migration of the contaminants, or 3) isolation and containment of the contaminated ground to reduce contaminant migration and control potential detrimental effects to human health. Where contamination has to be removed, ex situ and in situ techniques are available which minimize the waste requiring disposal to an LLW repository. These techniques include: 1) detector-based segregation 2) soil washing by particle separations 3) oil washing with chemical leaching agents 4) electro remediation 5) phyto remediation. Although many technologies are potentially applicable, their application to the remediation of a specific contaminated site is dependent on a number of factors and related to detailed site characterization studies, results from development trials and BPEO (best practicable environmental option) studies. Those factors considered of particular importance are: 1) the clean-up target 2) technical feasibility relative to the particular site, soil and contaminant characteristics, and time frame 3) site infrastructure arrangements and needs, the working life of the site and the duration of institutional care 4) long-term monitoring arrangements for slow remedial techniques or for immobilization and containment techniques 5) validation of the remediation 6) health and

  15. Evaluate the use of space monitoring methods for the study of the ecological state of the territory contaminated with heavy metals

    Directory of Open Access Journals (Sweden)

    Kroik G.A.

    2010-06-01

    Full Text Available Possibilities of modern Earth remote sensing systems are investigated in the space environmental monitoring of areas, contaminated with heavy metals, and the best of them are identified. The most informative E-field radiation spectrum zones for remote indication of heavy metals are identified and the special spectral indexes are offered.

  16. Effects of Contamination Upon the Performance of X-Ray Telescopes

    Science.gov (United States)

    O'Dell, Stephen L.; Elsner, Ronald F.; Oosterbroek, Tim

    2010-01-01

    Particulate and molecular contamination can each impact the performance of x-ray telescope systems. Furthermore, any changes in the level of contamination between on-ground calibration and in-space operation can compromise the validity of the calibration. Thus, it is important to understand the sensitivity of telescope performance, especially the net effective area and the wings of the point spread function to contamination. Here, we quantify this sensitivity and discuss the flow-down of science requirements to contamination-control requirements. As an example, we apply this methodology to the International X-ray Observatory (IXO), currently under joint study by ESA, JAXA, and NASA.

  17. Effect of Piriformospora indica inoculation on root development and distribution of maize (Zea mays L.) in the presence of petroleum contaminated soil

    Science.gov (United States)

    Zamani, Javad; Hajabbasi, Mohammad Ali; Alaie, Ebrahim

    2014-05-01

    The root systems of most terrestrial plants are confronted to various abiotic and biotic stresses. One of these abiotic stresses is contamination of soil with petroleum hydrocarbon, which the efficiency of phytoremediation of petroleum hydrocarbons in soils is dependent on the ability of plant roots to development into the contaminated soils. Piriformospora indica represents a recently discovered fungus that transfers considerable beneficial impact to its host plants. A rhizotron experiment was conducted to study the effects of P. Indica inoculation on root distribution and root and shoot development of maize (Zea mays L.) in the presence of three patterns of petroleum contamination in the soil (subsurface contamination, continuous contamination and without contamination (control)). Root distribution and root and shoot development were monitored over time. The final root and shoot biomass and the final TPH concentration in the rhizosphere were determined. Analysis of digitized images which were prepared of the tracing of the appeared roots along the front rhizotrons showed the depth and total length of root network in the contamination treatments were significantly decreased. Although the degradation of TPH in the rhizosphere of maize was significant, but there were no significant differences between degradation of TPH in the rhizosphere of +P. indica plants in comparison to -P. indica plants.

  18. Shifting the Paradigm for Long Term Monitoring at Legacy Sites to Improve Performance while Reducing Cost

    International Nuclear Information System (INIS)

    Eddy-Dilek, Carol A.; Looney, Brian B.; Seaman, John; Kmetz, Thomas

    2013-01-01

    A major issue facing many government and private industry sites that were previously contaminated with radioactive and chemical wastes is that often the sites cannot be cleaned up enough to permit unrestricted human access. These sites will require long-term management, in some cases indefinitely, leaving site owners with the challenge of protecting human health and environmental quality in a cost effective manner. Long-term monitoring of groundwater contamination is one of the largest projected costs in the life cycle of environmental management at the Savannah River Site (SRS), the larger DOE complex, and many large federal and private sites. Currently, most monitoring strategies are focused on laboratory measurements of contaminants measured in groundwater samples collected from wells. This approach is expensive, and provides limited and lagging information about the effectiveness of cleanup activities and the behavior of the residual contamination. Over the last twenty years, DOE and other federal agencies have made significant investments in the development of various types of sensors and strategies that would allow for remote analysis of contaminants in groundwater, but these approaches do not promise significant reductions in risk or cost. Scientists at SRS have developed a new paradigm to simultaneously improve the performance of long term monitoring systems while lowering the overall cost of monitoring. This alternative approach incorporates traditional point measurements of contaminant concentration with measurements of controlling variables including boundary conditions, master variables, and traditional plume/contaminant variables. Boundary conditions are the overall driving forces that control plume movement and therefore provide leading indication to changes in plume stability. These variables include metrics associated with meteorology, hydrology, hydrogeology, and land use. Master variables are the key variables that control the chemistry of the

  19. Biopiles - demonstration of cost effective biological remediation of furnace oil contaminated soils

    International Nuclear Information System (INIS)

    Kirchmair, G.A.

    1998-01-01

    Approximately 900 tonnes of soil was contaminated at a rural manufacturing facility near Collingwood, Ontario, when a 9000 litre underground furnace oil storage tank sprang a leak. The contaminated soil was excavated and stockpiled at the site and the leak was repaired. The Ontario Ministry of the Environment ordered that the owner treat the soil to the proper criteria or have the soil removed from the site and properly disposed of at a licensed landfill facility. Barenco was hired to treat the soil. Bioremediation began in December 1994 with the creation of nine above-ground biopiles which were constructed through the addition of nutrients (manure from a local farmer). Piping for air injection and treatment were located throughout the biopiles. The biopiles were then covered with 6 mil black HDPE plastic. The progress of the bioremediation was monitored regularly through measurement of carbon dioxide and oxygen concentrations in the biopiles. By October 1995, the soil was treated to within the appropriate criteria. In 10 months, the total petroleum hydrocarbon concentrations in the polluted soil were reduced from an average of 2690 ppm to 275 ppm. This simple and cost effective approach can also be used to remediate soils impacted with diesel fuels

  20. Economics of place-based monitoring under the safe drinking water act, part II: design and development of place-based monitoring strategies.

    Science.gov (United States)

    Brands, Edwin; Rajagopal, R

    2008-08-01

    The goals of environmental legislation and associated regulations are to protect public health, natural resources, and ecosystems. In this context, monitoring programs should provide timely and relevant information so that the regulatory community can implement legislation in a cost-effective and efficient manner. The Safe Drinking Water Act (SDWA) of 1974 attempts to ensure that public water systems (PWSs) supply safe water to its consumers. As is the case with many other federal environmental statutes, SDWA monitoring has been implemented in relatively uniform fashion across the United States. In this three part series, spatial and temporal patterns in water quality data are utilized to develop, compare, and evaluate the economic performance of alternative place-based monitoring approaches to current monitoring practice. Part II: Several factors affect the performance of monitoring strategies, including: measurable objectives, required precision in estimates, acceptable confidence levels of such estimates, available budget for sampling. In this paper, we develop place-based monitoring strategies based on extensive analysis of available historical water quality data (1960-1994) of 19 Iowa community water systems. These systems supply potable water to over 350,000 people. In the context of drinking water, the objective is to protect public health by utilizing monitoring resources to characterize contaminants that are detectable, and are close to exceeding health standards. A place-based monitoring strategy was developed in which contaminants were selected based on their historical occurrence, rather than their appearance on the SDWA contaminant list. In a subset of the water systems, the temporal frequency of monitoring for one ubiquitous contaminant, nitrate, was tailored to patterns in its historical occurrence and concentration. Three sampling allocation models (linear, quadratic, and cubic) based on historic patterns in peak occurrence were developed and

  1. Effect-directed analysis supporting monitoring of aquatic environments--An in-depth overview.

    Science.gov (United States)

    Brack, Werner; Ait-Aissa, Selim; Burgess, Robert M; Busch, Wibke; Creusot, Nicolas; Di Paolo, Carolina; Escher, Beate I; Mark Hewitt, L; Hilscherova, Klara; Hollender, Juliane; Hollert, Henner; Jonker, Willem; Kool, Jeroen; Lamoree, Marja; Muschket, Matthias; Neumann, Steffen; Rostkowski, Pawel; Ruttkies, Christoph; Schollee, Jennifer; Schymanski, Emma L; Schulze, Tobias; Seiler, Thomas-Benjamin; Tindall, Andrew J; De Aragão Umbuzeiro, Gisela; Vrana, Branislav; Krauss, Martin

    2016-02-15

    Aquatic environments are often contaminated with complex mixtures of chemicals that may pose a risk to ecosystems and human health. This contamination cannot be addressed with target analysis alone but tools are required to reduce this complexity and identify those chemicals that might cause adverse effects. Effect-directed analysis (EDA) is designed to meet this challenge and faces increasing interest in water and sediment quality monitoring. Thus, the present paper summarizes current experience with the EDA approach and the tools required, and provides practical advice on their application. The paper highlights the need for proper problem formulation and gives general advice for study design. As the EDA approach is directed by toxicity, basic principles for the selection of bioassays are given as well as a comprehensive compilation of appropriate assays, including their strengths and weaknesses. A specific focus is given to strategies for sampling, extraction and bioassay dosing since they strongly impact prioritization of toxicants in EDA. Reduction of sample complexity mainly relies on fractionation procedures, which are discussed in this paper, including quality assurance and quality control. Automated combinations of fractionation, biotesting and chemical analysis using so-called hyphenated tools can enhance the throughput and might reduce the risk of artifacts in laboratory work. The key to determining the chemical structures causing effects is analytical toxicant identification. The latest approaches, tools, software and databases for target-, suspect and non-target screening as well as unknown identification are discussed together with analytical and toxicological confirmation approaches. A better understanding of optimal use and combination of EDA tools will help to design efficient and successful toxicant identification studies in the context of quality monitoring in multiply stressed environments. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Abnormal ''Contamination' Levels On Garden Appliances

    International Nuclear Information System (INIS)

    German, U.; Levinson, S.; Elmelech, V.; Pelled, O.; Tshuva, A.; Laichter, Y.

    1999-01-01

    During routine contamination checks we encountered an abnormal high level of Alpha and Beta emitting radioisotopes on working gloves of employees of the gardening department. It came out that the source was due to ''contamination'' levels on steering wheels of some gardening machines. In order to ensure that no real contamination of these workers was involved , a series of checks was started to identity the source of the abnormal levels found during monitoring

  3. Contamination Event Detection with Multivariate Time-Series Data in Agricultural Water Monitoring

    Directory of Open Access Journals (Sweden)

    Yingchi Mao

    2017-12-01

    Full Text Available Time series data of multiple water quality parameters are obtained from the water sensor networks deployed in the agricultural water supply network. The accurate and efficient detection and warning of contamination events to prevent pollution from spreading is one of the most important issues when pollution occurs. In order to comprehensively reduce the event detection deviation, a spatial–temporal-based event detection approach with multivariate time-series data for water quality monitoring (M-STED was proposed. The M-STED approach includes three parts. The first part is that M-STED adopts a Rule K algorithm to select backbone nodes as the nodes in the CDS, and forward the sensed data of multiple water parameters. The second part is to determine the state of each backbone node with back propagation neural network models and the sequential Bayesian analysis in the current timestamp. The third part is to establish a spatial model with Bayesian networks to estimate the state of the backbones in the next timestamp and trace the “outlier” node to its neighborhoods to detect a contamination event. The experimental results indicate that the average detection rate is more than 80% with M-STED and the false detection rate is lower than 9%, respectively. The M-STED approach can improve the rate of detection by about 40% and reduce the false alarm rate by about 45%, compared with the event detection with a single water parameter algorithm, S-STED. Moreover, the proposed M-STED can exhibit better performance in terms of detection delay and scalability.

  4. Monitoring of Environmental Contamination and Addressing Health Risks Through the Analysis of Teeth by Means of Nuclear Techniques

    International Nuclear Information System (INIS)

    Oliveira, M.C.C.; Arruda-Neto, J.D.T.; Deppman, A.; Likhachev, V.P.; Medero, D.R.; Luzardo, F.M.; Cazorla, L.L.; Dias, J.F.; Yoneama, M.L.

    2003-01-01

    Radionuclides (mostly uranium and thorium) and heavy metals (lead and cadmium) are environmental contaminants produced by agricultural and industrial activities, or are simply the result of soil and water pollution by non regular human activities (e.g. disposal of garbage in rivers and water ponds). Humans incorporate these contaminants via the food chain, where bones are the most important target-organ. The incidence of health risk and hazards would depend, obviously, on the time length and intensity of such incorporation. However, while in vivo monitoring of human bones is difficult, the analysis of teeth is a promising possibility, particularly for the quantification of lead and cadmium in deciduous tooth (milk tooth), and uranium in adult tooth. This study will be focused, initially, on the Guarapiranga dam and on the human settlements located in its surroundings. Their teeth will be collected and classified by age and social-economical status, with the collaboration of the Dentistry School from UNISA, which is developing several social tasks in the Guarapiranga region. Water, plants and fishes will be collected and analyzed too, aiming at biokinetic al study of contaminants, particularly the transfer dynamics among the species of the dam. (Author)

  5. Wind effected redistribution of surface contamination. Progress report, September 1974--August 1975

    International Nuclear Information System (INIS)

    Amato, A.J.

    1975-01-01

    Theoretical resuspension ratios were computed through the extension of a one-dimensional model used to simulate the wind effected movement of surface contaminants. The surface movement of contamination associated with inhalable size particles was considered in relation to time, space, wind velocity, distance from the source, soil resuspension ratios, and other variables. A computer program was developed to calculate the wind effected distribution of surface contaminants. (U.S.)

  6. Nutrients versus emerging contaminants-Or a dynamic match between subsidy and stress effects on stream biofilms.

    Science.gov (United States)

    Aristi, I; Casellas, M; Elosegi, A; Insa, S; Petrovic, M; Sabater, S; Acuña, V

    2016-05-01

    Freshwater ecosystems are threatened by multiple anthropogenic stressors, which might be differentiated into two types: those that reduce biological activity at all concentrations (toxic contaminants), and those that subsidize biological activity at low concentrations and reduce it at high concentrations (assimilable contaminants). When occurring in mixtures, these contaminants can have either antagonistic, neutral or synergistic effects; but little is known on their joint effects. We assessed the interaction effects of a mixture of assimilable and toxic contaminants on stream biofilms in a manipulative experiment using artificial streams, and following a factorial design with three nutrient levels (low, medium or high) and either presence or absence of a mixture of emerging contaminants (ciprofloxacin, erythromycin, diclofenac, methylparaben, and sulfamethoxazole). We measured biofilm biomass, basal fluorescence, gross primary production and community respiration. Our initial hypotheses were that biofilm biomass and activity would: increase with medium nutrient concentrations (subsidy effect), but decrease with high nutrient concentrations (stress effect) (i); decrease with emerging contaminants, with the minimum decrease at medium nutrient concentrations (antagonistic interaction between nutrients subsidy and stress by emerging contaminants) and the maximum decrease at high nutrient concentrations (synergistic interaction between nutrients and emerging contaminants stress) (ii). All the measured variables responded linearly to the available nutrients, with no toxic effect at high nutrient concentrations. Emerging contaminants only caused weak toxic effects in some of the measured variables, and only after 3-4 weeks of exposure. Therefore, only antagonistic interactions were observed between nutrients and emerging contaminants, as medium and high nutrient concentrations partly compensated the harmful effects of emerging contaminants during the first weeks of the

  7. Cumulative health risk assessment: integrated approaches for multiple contaminants, exposures, and effects

    International Nuclear Information System (INIS)

    Rice, Glenn; Teuschler, Linda; MacDonel, Margaret; Butler, Jim; Finster, Molly; Hertzberg, Rick; Harou, Lynne

    2007-01-01

    Available in abstract form only. Full text of publication follows: As information about environmental contamination has increased in recent years, so has public interest in the combined effects of multiple contaminants. This interest has been highlighted by recent tragedies such as the World Trade Center disaster and hurricane Katrina. In fact, assessing multiple contaminants, exposures, and effects has long been an issue for contaminated sites, including U.S. Department of Energy (DOE) legacy waste sites. Local citizens have explicitly asked the federal government to account for cumulative risks, with contaminants moving offsite via groundwater flow, surface runoff, and air dispersal being a common emphasis. Multiple exposures range from ingestion and inhalation to dermal absorption and external gamma irradiation. Three types of concerns can lead to cumulative assessments: (1) specific sources or releases - e.g., industrial facilities or accidental discharges; (2) contaminant levels - in environmental media or human tissues; and (3) elevated rates of disease - e.g., asthma or cancer. The specific initiator frames the assessment strategy, including a determination of appropriate models to be used. Approaches are being developed to better integrate a variety of data, extending from environmental to internal co-location of contaminants and combined effects, to support more practical assessments of cumulative health risks. (authors)

  8. Near-facility environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, J.W.; Johnson, A.R.; Markes, B.M.; McKinney, S.M.; Perkins, C.J.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the routine near-facility environmental monitoring programs which are presently being conducted at the Hanford Site. Several types of environmental media are sampled near nuclear facilities to monitor the effectiveness of waste management and restoration activities, and effluent treatment and control practices. These media include air, surface water and springs, surface contamination, soil and vegetation, investigative sampling (which can include wildlife), and external radiation. Sampling and analysis information and analytical results for 1994 for each of these media are summarized in this section. Additional data and more detailed information may be found in Westinghouse Hanford Company Operational Environmental Monitoring Annual Report, Calendar Year 1994.

  9. Program of individual monitoring of the internal contamination and their implementation in the Republic the Cuba

    International Nuclear Information System (INIS)

    Lopez Bejerano, Gladys M.; Capote Ferrera, Eduardo; Fernandez Gomez, Isis M.; Acosta Rodriguez, Nancy; Carrazana Gonzalez, Jorge A.; Cruz Suarez, Rodolfo

    2008-01-01

    Full text: In different Cuban institutions linked fundamentally to the medical practice of nuclear medicine and the investigations, it is worked with sources open of ionizing radiations, that which makes indispensable the existence of a system of radiological surveillance that includes the control radiological individual of the received doses as a result of the occupational, such exhibition that is guaranteed that the exhibition of the Hard-working Exposed Occupationally, stay inside the recommended limits, in the International Basic Norms of Protection against the Ionizing radiations and safe-deposit of the Sources of Radiation (NBIS) and in turn adopted in the Norma Cuban. From the year 1986 in the Center of Protection and Hygiene of the Radiations is carried out in way centralized this control; but with the inconvenience of not being able to carry out the same one to workers from the domestic interior when not being feasible the transfer of these toward its headquarters, reason why the doses were ignored received in an important number of these. In and of itself the Laboratory of Internal Contamination of this institution in these years has developed managed works to define firstly, for each institution, the program of monitoring of the internal contamination of its workers using for it the methodology recommended by the OIEA where the potential doses are evaluated that for incorporation these they receive and whose results suggested the introduction of a program of individual monitoring as behavior to continue in most of the institutions. In correspondence with it was designed and established a program that included the study of feasibility of the existent equipment in the institutions to carry out the monitoring of the internal contamination using technical of measuring in vivo and in vitro, as it corresponds, their calibration, the establishment of procedures that respond to the requirements of a System of Quality for the Norma ISO/IEC 17025 and

  10. Effect of contaminant concentration on in situ bacterial sulfate reduction and methanogenesis in phenol-contaminated groundwater

    International Nuclear Information System (INIS)

    Baker, Kieran M.; Bottrell, Simon H.; Thornton, Steven F.; Peel, Kate E.; Spence, Michael J.

    2012-01-01

    The availability of dissolved O 2 can limit biodegradation of organic compounds in aquifers. Where O 2 is depleted, biodegradation proceeds via anaerobic processes, including NO 3 -, Mn(IV)-, Fe(III)- and SO 4 -reduction and fermentation/methanogenesis. The environmental controls on these anaerobic processes must be understood to support implementation of management strategies such as monitored natural attenuation (MNA). In this study stable isotope analysis is used to show that the relative significance of two key anaerobic biodegradation processes (bacterial SO 4 reduction (BSR) and methanogenesis) in a phenol-contaminated sandstone aquifer is sensitive to spatial and temporal changes in total dissolved phenols concentration (TPC) (= phenol + cresols + dimethylphenols) over a 5-a period. In general, 34 SO 4 -enrichment (characteristic of bacterial SO 4 reduction) is restricted spatially to locations where TPC −1 . In contrast, 13 C-depleted CH 4 and 13 C-enriched CO 2 isotope compositions (characteristic of methanogenesis) were measured at TPC up to 8000 mg L −1 . This is consistent with previous studies that demonstrate suppression of BSR at TPC of >500 mg L −1 , and suggests that methanogenic microorganisms may have a higher tolerance for TPC in this contaminant plume. It is concluded that isotopic enrichment trends can be used to identify conditions under which in situ biodegradation may be limited by the properties of the biodegradation substrate (in this case TPC). Such data may be used to deduce the performance of MNA for contaminated groundwater in similar settings.

  11. The Thirty Years’ Results of Radiation Hygienic Monitoring of Tula Region territories contaminated due to the Chernobyl NPP accident

    Directory of Open Access Journals (Sweden)

    V. V. Boldyreva

    2016-01-01

    Full Text Available Over 50% of Tula Region areas were contaminated after the Chernobyl NPP accident. The article provides the thirty years’ results of radiation hygienic monitoring of the Chernobyl accidental fallout - affected areas in Tula Region. The radiation situation is assessed at the initial accidental period and at the current stage. The initial levels of gamma - radiation dose intensity (up to 35 mcSv/hr are identified for the period of the “iodine” hazard along with the tabular data on the dose intensity relative stabilization by the beginning of August 1986 due to iodine-131 decay. The information is presented regarding iodine-131 tentative maximum permissible level exceedance in the dairy products of the two most contaminated regional areas - Plavskoye and Arsenievskoye. The article also provides the laboratory data on the total beta - activity in the foodstuffs in 1986-1987 and cesium-137 maximum permissible level exceedence in 1986. The radionuclide maximum permissible level exceedances in foodstuffs were registered only in 1986 due to the plants surface contamination whereas in the forest mushrooms those exceedances were repeatedly found until 2004. The black earths and grey forest soils had a benign impact upon the intensity of the radionuclide transfer into plants which resulted in the formation of internal radiation doses.At the current stage, the content of cesium-137 and strontium- 90 in the foodstuffs can only be quantified by a radiochemical method. The table covers all the districts within the boundaries of radiation contaminated zones. The radiochemical studies indicate the main dose - forming products. The article contains the table of internal and external radiation doses of the population in Plavsk town over 1986-1990 and displays the factors impacting population’s internal and external exposure. The Chernobyl - affected exposure dose of the population is mostly attributed to the external radiation and, for over twenty years, it

  12. LRAD surface monitoring results at TA-21

    International Nuclear Information System (INIS)

    Bounds, J.A.

    1995-01-01

    In August/September 1994, NIS-6 personnel used LRAD soil surface monitor technology to characterize the extent of alpha contamination on the surface of a parking lot adjacent to TA-21, LANL, known as Material Disposal Area B. This report documents that monitoring. Based on this survey, there is no reason for concern about significant contamination in the parking area as a whole, although unexpected small hot spots could exist between the grid points where monitoring was performed. However, the grouping of high readings on the east side of the parking area does point to possible contamination at the level of 100 dpm/100 cm 2 or less (above background). Further monitoring or remediation of this area seems appropriate. In addition, because this was an alpha survey, one cannot rule out contamination under the asphalt or possibly between layers if it was paved more than once

  13. Hanford Site Groundwater Monitoring for Fiscal Year 2003

    Energy Technology Data Exchange (ETDEWEB)

    Hartman, Mary J.; Morasch, Launa F.; Webber, William D.

    2004-04-12

    This report presents the results of groundwater and vadose zone monitoring and remediation for fiscal year 2003 (October 2002 through September 2003) on the U.S. Department of Energy's Hanford Site, Washington. The most extensive contaminant plumes in groundwater are tritium, iodine-129, and nitrate, which all had multiple sources and are very mobile in groundwater. The largest portions of these plumes are migrating from the central Hanford Site to the southeast, toward the Columbia River. Concentrations of tritium, nitrate, and some other contaminants continued to exceed drinking water standards in groundwater discharging to the river in some locations. However, contaminant concentrations in river water remained low and were far below standards. Carbon tetrachloride and associated organic constituents form a relatively large plume beneath the central part of the Hanford Site. Hexavalent chromium is present in smaller plumes beneath the reactor areas along the river and beneath the central part of the site. Strontium-90 exceeds standards beneath all but one of the reactor areas, and technetium-99 and uranium are present in the 200 Areas. Uranium exceeds standards in the 300 Area in the south part of the Hanford Site. Minor contaminant plumes with concentrations greater than standards include carbon-14, cesium-137, cis-1,2-dichloroethene, cyanide, fluoride, plutonium, and trichloroethene. Monitoring for the ''Comprehensive Environmental Response, Compensation, and Liability Act'' is conducted in 11 groundwater operable units. The purpose of this monitoring is to define and track plumes and to monitor the effectiveness of interim remedial actions. Interim groundwater remediation in the 100 Areas continued with the goal of reducing the amount of chromium (100-K, 100-D, and 100-H) and strontium-90 (100-N) reaching the Columbia River. The objective of two interim remediation systems in the 200 West Area is to prevent the spread of carbon

  14. Shifting the Paradigm for Long Term Monitoring at Legacy Sites to Improve Performance while Reducing Costs - 13422

    International Nuclear Information System (INIS)

    Eddy-Dilek, Carol A; Looney, Brian B.; Gaughan, Thomas; Kmetz, Thomas; Seaman, John

    2013-01-01

    A major issue facing many government and private industry sites that were previously contaminated with radioactive and chemical wastes is that often the sites cannot be cleaned up enough to permit unrestricted human access. These sites will require long-term management, in some cases indefinitely, leaving site owners with the challenge of protecting human health and environmental quality in a cost effective manner. Long-term monitoring of groundwater contamination is one of the largest projected costs in the life cycle of environmental management at the Savannah River Site (SRS), the larger DOE complex, and many large federal and private sites. Currently, most monitoring strategies are focused on laboratory measurements of contaminants measured in groundwater samples collected from wells. This approach is expensive, and provides limited and lagging information about the effectiveness of cleanup activities and the behavior of the residual contamination. Over the last twenty years, DOE and other federal agencies have made significant investments in the development of various types of sensors and strategies that would allow for remote analysis of contaminants in groundwater, but these approaches do not promise significant reductions in risk or cost. Scientists at SRS have developed a new paradigm to simultaneously improve the performance of long term monitoring systems while lowering the overall cost of monitoring. This alternative approach incorporates traditional point measurements of contaminant concentration with measurements of controlling variables including boundary conditions, master variables, and traditional plume/contaminant variables. Boundary conditions are the overall driving forces that control plume movement and therefore provide leading indication to changes in plume stability. These variables include metrics associated with meteorology, hydrology, hydrogeology, and land use. Master variables are the key variables that control the chemistry of the

  15. Shifting the Paradigm for Long Term Monitoring at Legacy Sites to Improve Performance while Reducing Costs - 13422

    Energy Technology Data Exchange (ETDEWEB)

    Eddy-Dilek, Carol A; Looney, Brian B. [Savannah River National Laboratory (United States); Gaughan, Thomas; Kmetz, Thomas [Savannah River Nuclear Solutions, LLC (United States); Seaman, John [Savannah River Ecology Laboratory (United States)

    2013-07-01

    A major issue facing many government and private industry sites that were previously contaminated with radioactive and chemical wastes is that often the sites cannot be cleaned up enough to permit unrestricted human access. These sites will require long-term management, in some cases indefinitely, leaving site owners with the challenge of protecting human health and environmental quality in a cost effective manner. Long-term monitoring of groundwater contamination is one of the largest projected costs in the life cycle of environmental management at the Savannah River Site (SRS), the larger DOE complex, and many large federal and private sites. Currently, most monitoring strategies are focused on laboratory measurements of contaminants measured in groundwater samples collected from wells. This approach is expensive, and provides limited and lagging information about the effectiveness of cleanup activities and the behavior of the residual contamination. Over the last twenty years, DOE and other federal agencies have made significant investments in the development of various types of sensors and strategies that would allow for remote analysis of contaminants in groundwater, but these approaches do not promise significant reductions in risk or cost. Scientists at SRS have developed a new paradigm to simultaneously improve the performance of long term monitoring systems while lowering the overall cost of monitoring. This alternative approach incorporates traditional point measurements of contaminant concentration with measurements of controlling variables including boundary conditions, master variables, and traditional plume/contaminant variables. Boundary conditions are the overall driving forces that control plume movement and therefore provide leading indication to changes in plume stability. These variables include metrics associated with meteorology, hydrology, hydrogeology, and land use. Master variables are the key variables that control the chemistry of the

  16. Radiological interference from personal articles in occupational radiation monitoring

    International Nuclear Information System (INIS)

    Krishnakumar, P.; Jayan, M.P; Pawar, V.J; Patil, S.L; Selvamani, N.; Vedram; Sureshkumar, M.K.; Chinnaesakki, S.

    2016-01-01

    This paper discusses the presence of radioactivity in some personal articles worn on sacred thread and the related difficulties faced by health physicists during occupational radiation monitoring in nuclear facilities. In an incident, the portal monitor installed at the exit gate of a nuclear facility indicated contamination on self of a radiation worker while passing through it. The worker was therefore, subjected to thorough check for external contamination by the plant health physicist, using a pan-cake contamination monitor. All the clothing of the person was also checked for contamination. On further detailed examination, a dark brownish personal article hanging on a sacred thread from his neck was found to be the source of contamination. This presentation aims at giving information to the health physics community on the possibility of such interferences during personal monitoring in nuclear facilities

  17. Time-lapse electrical geophysical monitoring of amendment-based biostimulation

    Science.gov (United States)

    Johnson, Timothy C.; Versteeg, Roelof J.; Day-Lewis, Frederick D.; Major, William; Lane, John W.

    2015-01-01

    Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling-based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation.Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation.In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surface-based ERT in conjunction with limited field sampling to improve spatial

  18. Internal contamination monitoring through measurements in vivo at whole body contamination unity of IRD-CNEN, Rio de Janeiro, Brazil; Monitoracao da contaminacao interna atraves de medicoes in vivo na Unidade de Contador de Corpo Inteiro do IRD-CNEN, Rio de Janeiro, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Ana Leticia A.; Lucena, Eder A.; Dantas, Bernardo M., E-mail: adantas@ird.gov.b, E-mail: eder@ird.gov.b, E-mail: bmdantas@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. de Monitoracao In Vivo. Servico de Monitoracao Individual Interna

    2011-10-26

    The present work approaches the internal contamination monitoring capacity through measurements performed at the Whole-body Counter Unity of the in-vivo monitoring laboratory (LABMIV) of the IRD-CNEN, Rio de Janeiro, Brazil, present thr main parameters related to the monitoring techniques developed, and the the available instrumentation for identification and quantification in vivo of photon emitter radionuclides with energy in the range of 10-3000 keV, incorporated by workers and public individuals

  19. Metal and Isotope Analysis of Bird Feathers in a Contaminated Estuary Reveals Bioaccumulation, Biomagnification, and Potential Toxic Effects.

    Science.gov (United States)

    Einoder, L D; MacLeod, C K; Coughanowr, C

    2018-07-01

    The Derwent estuary, in south east Tasmania, is highly contaminated with heavy metals, mainly due to past industrial pollution. This study sought to determine the extent of contamination, bioaccumulation, and biomagnification in the resident bird community and therefore to infer the potential for adverse effects in birds. Thirteen metals were measured from breast feathers (n = 51 individuals) of eight sympatric species of aquatic bird. Stable carbon (δ 13 C) and nitrogen (δ 15 N) isotopes were used to identify dietary sources of contaminants, trophic level, and potential biomagnification through food chains. Generalised linear models revealed that metal burdens were often poorly correlated with δ 13 C, indicating their uptake from a range of freshwater, brackish, and marine carbon sources-not surprising due to widespread contamination across the tidal estuary. Feather mercury increased significantly with trophic level (inferred from δ 15 N). White-bellied Sea-eagle Haliaeetus leucogaster samples contained 240 times more mercury than feral Goose Anser cygnoides. Feather arsenic and copper concentrations were significantly higher in birds feeding lower in the food chain. For several piscivorous species, both chick and adults were sampled revealing significantly higher feather mercury, zinc, and selenium in adults. Feathers from birds found dead along the banks of the estuary had significantly higher lead loads than from live birds, and numerous individuals had levels of mercury, zinc, and lead above toxic thresholds reported in other studies. These results highlight the need to include biota from higher trophic levels in contaminant monitoring programs to understand fully the fate and broader implications of contaminants in the environment.

  20. Title: Effect of abiotic stress on reduction of microbial contamination ...

    African Journals Online (AJOL)

    TERI

    2016-03-30

    Mar 30, 2016 ... Full Length Research Paper. Effect of osmotic stress on in vitro propagation of. Musa sp. ... In vitro propagation of banana preferably use sword sucker as explant source where microbial contamination poses a great problem in ... micropropagation. Endo-bacterial contamination is one of the major problems ...

  1. Analysis and characterization of contamination in EUV reticles

    Science.gov (United States)

    Okoroanyanwu, Uzodinma; Dittmar, Kornelia; Fahr, Torsten; Wallow, Tom; La Fontaine, Bruno; Wood, Obert; Holfeld, Christian; Bubke, Karsten; Peters, Jan-Hendrik

    2010-04-01

    A host of complementary imaging techniques (Scanning Electron Microscopy), surface analytical technique (Auger Electron Spectroscopy, AES), chemical analytical and speciation techniques (Grazing Incidence Reflectance Fourier-Transform Infrared Spectroscopy, GIR-FTIR; and Raman spectroscopy) have been assessed for their sensitivity and effectiveness in analyzing contamination on three EUV reticles that were contaminated to varying degrees. The first reticle was contaminated as a result of its exposure experience on the SEMATECH EUV Micro Exposure Tool (MET) at Lawrence Berkeley National Laboratories, where it was exposed to up to 80 hours of EUV radiation. The second reticle was a full-field reticle, specifically designed to monitor molecular contamination, and exposed to greater than 1600J/cm2 of EUV radiation on the ASML Alpha Demo Tool (ADT) in Albany Nanotech in New York. The third reticle was intentionally contaminated with hydrocarbons in the Microscope for Mask Imaging and Contamination Studies (MIMICS) tool at the College of Nanoscale Sciences of State University of New York at Albany. The EUV reflectivities of some of these reticles were measured on the Advanced Light Source EUV Reflectomer at Lawrence Berkeley National Laboratories and PTB Bessy in Berlin, respectively. Analysis and characterization of thin film contaminants on the two EUV reticles exposed to varying degrees of EUV radiation in both MET and ADT confirm that the two most common contamination types are carbonization and surface oxidation, mostly on the exposed areas of the reticle, and with the MET being significantly more susceptible to carbon contamination than the ADT. While AES in both surface scanning and sputter mode is sensitive and efficient in analyzing thin contaminant films (of a few nanometers), GIRFTIR is sensitive to thick films (of order of a 100 nm or more on non-infra-red reflecting substrates), Raman spectroscopy is not compatible with analyzing such contaminants because of

  2. Bulk monitoring and segregation of radioactive wastes

    Energy Technology Data Exchange (ETDEWEB)

    Beddow, H.; Adsley, I.; Pearman, I.; Sweeney, A.; Davies, M., E-mail: helen.beddow@nuvia.co.uk [Nuvia Limited, Harwell Oxford, Didcot, Oxfordshire (United Kingdom)

    2014-07-01

    Several sites in the UK are contaminated by radioactive legacy wastes. These include; radium luminising sites and more recently the oil, and (potentially) fracking industries; sites contaminated from thorium gas mantle factories; old nuclear research sites; nuclear power sites, and the Sellafield reprocessing site. Nuvia has developed a suite of technologies to map the location of and to recover and process wastes during remedial operations. The main method for delineating contaminated areas in-situ is by use of the Groundhog system, whilst bulk monitoring methods employ the Gamma Excavation Monitor, the High Resolution Assay Monitor, and the Conveyor Active Particle System. (author)

  3. Bulk monitoring and segregation of radioactive wastes

    International Nuclear Information System (INIS)

    Beddow, H.; Adsley, I.; Pearman, I.; Sweeney, A.; Davies, M.

    2014-01-01

    Several sites in the UK are contaminated by radioactive legacy wastes. These include; radium luminising sites and more recently the oil, and (potentially) fracking industries; sites contaminated from thorium gas mantle factories; old nuclear research sites; nuclear power sites, and the Sellafield reprocessing site. Nuvia has developed a suite of technologies to map the location of and to recover and process wastes during remedial operations. The main method for delineating contaminated areas in-situ is by use of the Groundhog system, whilst bulk monitoring methods employ the Gamma Excavation Monitor, the High Resolution Assay Monitor, and the Conveyor Active Particle System. (author)

  4. Europe-wide survey of estrogenicity in wastewater treatment plant effluents: the need for the effect-based monitoring.

    Science.gov (United States)

    Jarošová, Barbora; Erseková, Anita; Hilscherová, Klára; Loos, Robert; Gawlik, Bernd M; Giesy, John P; Bláha, Ludek

    2014-09-01

    A pan-European monitoring campaign of the wastewater treatment plant (WWTP) effluents was conducted to obtain a concise picture on a broad range of pollutants including estrogenic compounds. Snapshot samples from 75 WWTP effluents were collected and analysed for concentrations of 150 polar organic and 20 inorganic compounds as well as estrogenicity using the MVLN reporter gene assay. The effect-based assessment determined estrogenicity in 27 of 75 samples tested with the concentrations ranging from 0.53 to 17.9 ng/L of 17-beta-estradiol equivalents (EEQ). Approximately one third of municipal WWTP effluents contained EEQ greater than 0.5 ng/L EEQ, which confirmed the importance of cities as the major contamination source. Beside municipal WWTPs, some treated industrial wastewaters also exhibited detectable EEQ, indicating the importance to investigate phytoestrogens released from plant processing factories. No steroid estrogens were detected in any of the samples by instrumental methods above their limits of quantification of 10 ng/L, and none of the other analysed classes of chemicals showed correlation with detected EEQs. The study demonstrates the need of effect-based monitoring to assess certain classes of contaminants such as estrogens, which are known to occur at low concentrations being of serious toxicological concern for aquatic biota.

  5. Early-stage bioassay for monitoring radioactive contamination in living livestock.

    Science.gov (United States)

    Yamaguchi, Toshiro; Sawano, Kaita; Kishimoto, Miori; Furuhama, Kazuhisa; Yamada, Kazutaka

    2012-12-01

    Soil samples from the ground surface and feces and blood from a mixed-breed male pig were collected on April 10, 2011 at a farm within 20 km of the Fukushima Daiichi nuclear power plant. The radioactivity of each sample was measured using a Ge semiconductor detector. Despite the fact that the pig had been fed non-contaminated imported feed, (131)I, (134)Cs and (137)Cs were detected in the feces, and (134)Cs and (137)Cs were detected in the blood clots. Because it is considerably difficult to measure radioactive contamination in the edible muscle of living livestock, bioassays are an option for the screening of radioactive contamination in living livestock to ensure food safety.

  6. The time-dependent effect of the biological component of 137Cs soil contamination

    International Nuclear Information System (INIS)

    Dederichs, H.; Pillath, J.; Lennartz, R.; Hill, P.; Hille, R.

    2004-01-01

    In investigations of the long-term development of the population dose in the highly contaminated regions of the Commonwealth of Independence States it was found that the external dose has not decreased as strongly as expected since 1992. Further investigations have shown that, contrary to expectations, no linear correlation can be observed between soil contamination and measured area dose rate. As a contribution towards clarifying these issues, the area dose rate and the soil contamination including the plant fraction were investigated in the Korma district, Belarus. It was found that it is necessary to cover and average over larger areas in order to determine from ground contamination the long-term development of the external dose commitment. This means that for this purpose the introduction of an ''effective'' surface contamination (sum of mineral and organic contamination components) is necessary. The phenomena observed are described in a model, which permits an analytical calculation of the contamination profile in soil taking migration and transfer effects into account. The differences observed between the measured soil contamination and the resulting external doses or the directly measured dose rate can be explained by the proposed model. Moreover, their long-term development can be calculated. The results show that a time decade after the accident the biological part of the ''effective'' soil contamination becomes dominant and cannot be neglected. (orig.)

  7. Obtaining Samples Representative of Contaminant Distribution in an Aquifer

    International Nuclear Information System (INIS)

    Schalla, Ronald; Spane, Frank A.; Narbutovskih, Susan M.; Conley, Scott F.; Webber, William D.

    2002-01-01

    Historically, groundwater samples collected from monitoring wells have been assumed to provide average indications of contaminant concentrations within the aquifer over the well-screen interval. In-well flow circulation, heterogeneity in the surrounding aquifer, and the sampling method utilized, however, can significantly impact the representativeness of samples as contaminant indicators of actual conditions within the surrounding aquifer. This paper identifies the need and approaches essential for providing cost-effective and technically meaningful groundwater-monitoring results. Proper design of the well screen interval is critical. An accurate understanding of ambient (non-pumping) flow conditions within the monitoring well is essential for determining the contaminant distribution within the aquifer. The ambient in-well flow velocity, flow direction and volumetric flux rate are key to this understanding. Not only do the ambient flow conditions need to be identified for preferential flow zones, but also the probable changes that will be imposed under dynamic conditions that occur during groundwater sampling. Once the in-well flow conditions are understood, effective sampling can be conducted to obtain representative samples for specific depth zones or zones of interest. The question of sample representativeness has become an important issue as waste minimization techniques such as low flow purging and sampling are implemented to combat the increasing cost of well purging and sampling at many hazardous waste sites. Several technical approaches (e.g., well tracer techniques and flowmeter surveys) can be used to determine in-well flow conditions, and these are discussed with respect to both their usefulness and limitations. Proper fluid extraction methods using minimal, (low) volume and no purge sampling methods that are used to obtain representative samples of aquifer conditions are presented

  8. False indications of 95Zr-95Nb internal contamination due to contaminated sacred thread

    International Nuclear Information System (INIS)

    Garg, S.P.; Singh, I.S.; Sharma, R.C.

    2000-01-01

    Whole body monitoring of a worker showed an apparent internal contamination with a considerable amount of 95 Zr- 95 Nb. Inhalation exposure was suspected to have taken place about a week earlier when he had last worked in the radioactive area. Unexpected fast clearance indicated by the third periodical weekly follow up monitoring was considered to be an abnormal behaviour. Investigations revealed an external contamination on a sacred thread, which the worker was putting on across his thorax and not removing it at the time of bath due to religious considerations. These studies have underscored that short term follow up measurements data should be critically scrutinized and a caution should be exercised in the interpretation such data particularly in case of such relatively short lived radionuclides. (author)

  9. Implementation of GIS-DSS PRANA within sustainable rehabilitation of radioactive contaminated territories

    International Nuclear Information System (INIS)

    Yatsalo, B.

    2003-01-01

    Full text: Analysis of the current situation in contaminated farms and settlements of Bryansk region is based on the monitoring data and model estimates. Model assessments of agricultural produce contamination, doses to the local population, radiological risk and results of countermeasure (CM) implementation have been carried out with the use of PRANA GIS-DSS. Applied Geographic Information System (GIS) PRANA is a Decision Support System (DSS) for implementation within the rehabilitation of radioactive contaminated territories. PRANA has been introduced for practical use in Bryansk as a GIS-DSS system for monitoring networking support and countermeasure analysis. The main blocks of the PRANA DSS are: libraries of electronic maps, including different layers of vector maps of landuse for all contaminated districts of Bryansk region: Novozybkov, Klintsy, Gordeevsky, Krasnogorsky, Zlynkovsky and Klimovsky (more than 30000 polygons of vector electronic maps); databases (radioecological, ecological, economic, demographic and other monitoring data and model parameters, including attributive information of vector electronic maps); model blocks for assessing: contamination of agricultural production, external and internal doses to the local population, radiological risks and corresponding results of CMs implementation; evaluation of CMs effectiveness and decision-making support an protection of the population and rehabilitation of radioactive contaminated territories both on local and regional/district levels (from separate settlement/field up to group of settlements/farms and region as a whole). The following 'risk indices' are considered within decision-making an Risk Based Land Management (RBLM) with the use of PRANA DSS: surface density contamination of territory with radionuclides ( 137 Cs, 90 Sr); contamination of agricultural production (plant growing and animal husbandry, including farm and private production); external and internal doses to the local population

  10. Electrokinetic remediation of contaminated soils: An update

    International Nuclear Information System (INIS)

    Lindgren, E.R.; Kozak, M.W.; Mattson, E.D.

    1992-01-01

    Electrokinetic remediation of chromium contaminated soil has been demonstrated for unsaturated 50-100 mesh sand with 10% moisture by weight. The initial region of sand contaminated with 100 ppm w chromate ions was completely cleansed of contamination. After 22 hours of treatment, chromate was found near the anode and apparently migrated at a rate of at least 0.40 cm/hr with a pore water current density of 2.26mA/cm 2 . An analogous run was made using the same sand and FD and C Red No. 40 as the contaminant at a molar concentration equivalent to the 100 ppm w Cr run. The position of the migrating dye was monitored photographically. After similar treatment conditions, the visual dye concentration profile exhibited characteristics similar to the chromate. The migration rate of the dye was slower than the chromate but the qualitative similarity of behavior in an electric field suggests the dye is an analog for chromate ions. The slower migration rate of the dye is not unexpected because the dye molecule is larger than chromate. The use of dye as an analog for chromate greatly accelerates the experimentation process in unsaturated soil because destructive sampling is not required to monitor the contaminant location. Experiments were also conducted to determine the effect of soil heterogeneities on the electrokinetic processes. Unsaturated sands in size fractions of 50-100 mesh (medium) and 100-200 mesh (fine) were studied both individually and in layers. The dye migration rate was accelerated in the tine sand and slowed in the medium sand of the layered experiment when compared with the corresponding individual experiments. This discrepancy was explained by estimating the current density in each layer which was proportionally higher in the fine layer and lower in the medium layer. These preliminary experiments illustrate the significant dependence of electromigration rates on current density. (author)

  11. Trust versus confidence: Microprocessors and personnel monitoring

    International Nuclear Information System (INIS)

    Chiaro, P.J. Jr.

    1993-01-01

    Due to recent technological advances, substantial improvements have been made in personnel contamination monitoring. In all likelihood, these advances will close out the days of manually frisking personnel for radioactive contamination. Unfortunately, as microprocessor-based monitors become more widely used, not only at commercial power reactors but also at government facilities, questions concerning their trustworthiness arise. Algorithms make decisions that were previously made by technicians. Trust is placed not in technicians but in machines. In doing this it is assumed that the machine never misses. Inevitably, this trust drops, due largely to ''false alarms''. This is especially true when monitoring for alpha contamination. What is a ''false alarm''? Do these machines and their algorithms that we put our trust in make mistakes? An analysis was performed on half-body and hand-and-foot monitors at Oak Ridge National Laboratory (ORNL) in order to justify the suggested confidence level used for alarm point determination. Sources used in this analysis had activities approximating ORNL's contamination limits

  12. Trust versus confidence: Microprocessors and personnel monitoring

    International Nuclear Information System (INIS)

    Chiaro, P.J. Jr.

    1994-01-01

    Due to recent technological advances, substantial improvements have been made in personnel contamination monitoring. In all likelihood, these advances will close out the days of manually frisking personnel for radioactive contamination. Unfortunately, as microprocessor-based monitors become more widely used, not only at commercial power reactors but also at government facilities, questions concerning their trustworthiness arise. Algorithms make decisions that were previously made by technicians. Trust is placed not in technicians but in machines. In doing this it is assumed that the machine never misses. Inevitably, this trust drops, due largely to ''false alarms''. This is especially true when monitoring for alpha contamination. What is a ''false alarm''? Do these machines and their algorithms that they put their trust in make mistakes? An analysis was performed on half-body and hand-and-foot monitors at Oak Ridge National Laboratory (ORNL) in order to justify the suggested confidence level used for alarm point determination. Sources used in this analysis had activities approximating ORNL's contamination limits

  13. Radiation monitoring network in Poland

    International Nuclear Information System (INIS)

    Grabowski, D.; Kurowski, W.; Muszynski, W.; Rubel, B.; Smagala, G.; Swietochowska, J.

    2001-01-01

    In Poland the radioactive contamination of the environment and food has been controlled since the early sixties by the Service for Measurements of Radioactive Contamination (SPSP). The service comprises a network of measuring stations and the Centre of Radioactive Contamination Measurements (COPSP). Actually, there are 100 measurement stations. The main task of such station is systematic measurement of radioactivity level in samples of environment components and food. Nine stations of SPSP acting within meteorological stations, ten stations of low level air radioactivity measurements (Aerosols Sampling Stations-500) and eleven permanent monitoring stations (PMS) form the radiation monitoring warning system in Poland. (author)

  14. Evaluation of the effectiveness of countermeasures in contaminated forests

    International Nuclear Information System (INIS)

    Fesenko, S.; Voigt, G.; Spiridonov, S.; Gontarenko, I.

    2004-01-01

    In many regions subjected to the contamination forest products play an important role in radiation impact on the population. The contribution of mushrooms and berries to the internal doses varies depending on the time after the accident up to 40-45%. To protect people against additional exposure associated with forest contamination an appropriate system of countermeasures should be applied. The decision making framework to optimise implementation of forest countermeasures in the long term after the ChNPP accident is described. The approach is based on the analysis of the main exposure pathways related to contaminated forest and application of different criteria (reduction of individual dose to population and members of critical groups, cost for countermeasures implementation; cost of averted dose of 1 man-Sv; secondary ecological effect and psycho-social impact) for the selection of optimal countermeasures strategies. Because of diversity of these criteria for selection of optimal countermeasures a decision support technology based on a multi-attributive analysis is applied. Results of the application of the approach proposed for the study area (Novozybkov district, Bryansk region, Russian Federation) are presented. Applicability of twelve forest countermeasure options is evaluated and their effectiveness in terms of cost and dose reduction is estimated for the current period. It has been found that limitation on mushrooms or berries collections to the species with low accumulation of radionuclides and mushrooms processing before consumption (for the population) and combined application of Prussian Blue with limitation of tree harvesting to the area with low doses to decrease exposure of the critical groups members are most justified for the long term after the accident in the most contaminated regions of Russia. The results emphasize the effectiveness of the application of a flexible technique to provide the optimization of forest countermeasures taking into

  15. Evaluation of a hygiene monitor for detection of contamination in dental surgeries.

    Science.gov (United States)

    Douglas, C W; Rothwell, P S

    1991-05-11

    Routines for disinfecting working surfaces in dental surgeries are difficult to monitor without time-consuming and labour-intensive microbiological techniques, yet effective monitoring is a vital part of cross-infection control. Easy to use, on-site methods would be valuable in this context. This study evaluates a portable monitor, the Biotrace Hygiene Monitor, which uses bioluminescence to measure adenosine triphosphate (ATP) on surfaces. Under laboratory conditions, the ability of the monitor to detect whole saliva and Streptococcus sanguis was determined and, in the general practice environment, the level of ATP on surfaces in five dental surgeries was assessed. The minimum amount of saliva detectable was 0.5 microliters and in surgeries, the monitor readily identified numerous surfaces with fairly high levels of ATP. Routine cleaning methods sometimes left ATP on surfaces at levels which represented a cross-infection risk, if it is assumed that the ATP derived from patients' saliva. Modification of cleaning methods resulted in a reduction of ATP levels to within that which could be considered reasonably practicably safe. It is concluded that the Biotrace Hygiene Monitor offers a simple and valuable means of monitoring dental practice cleaning routines.

  16. Ecotoxicological effects of decabromodiphenyl ether and cadmium contamination on soil microbes and enzymes.

    Science.gov (United States)

    Zhang, Wei; Zhang, Meng; An, Shuai; Xiong, Bang; Li, Hui; Cui, Changzheng; Lin, Kuangfei

    2012-08-01

    The ecotoxicological effects of decabromodiphenyl ether (BDE209) and cadmium (Cd) contamination on soil culturable microbial population, enzyme activity and bacterial community structure were investigated. Results of the indoor incubation test runs performed on many series of control and contaminated soil samples have demonstrated some notable toxic effects due to long term exposure to either or both contaminants. The two contaminants produced notable yet different toxic effects on the test microbes; the population of the exposed species generally declined according to certain dose-response relationships. The soil culturable microbial population and enzyme activity data show that the sensitivity to one or both contaminants followed the order of: bacteria>fungi>actinomycete and urease>saccharase, respectively. The interaction between BDE209 and Cd was dependent on both the exposure dose and time and that the joint toxic effects were synergistic, antagonistic or additive. The PCR-DGGE analysis data of species composition and richness suggest the synergistic combined effects on bacterial community structure during the 30d exposure. Pseudomonas tuomuerensis strain CCM 7280 and Pseudomonas alcaliphila strain AL15-21 were enriched, indicating these species might be major functional populations and highly tolerant. Such observations have provided the useful information of potential ecotoxicological effects of BDE209 and Cd contamination in the environment. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Long-range alpha detector for contamination monitoring

    International Nuclear Information System (INIS)

    MacArthur, D.W.; Allander, K.S.; McAtee, J.L.

    1991-01-01

    Historically, alpha detectors have been limited by the very short range of alpha particles in air and by relatively poor sensitivity, even if the particles are intercepted. Of necessity, these detectors are operated in a vacuum or in close proximity to the source if reasonable efficiency is desired. In our new long-range alpha detector (LRAD), alpha particles interact with the ambient air, producing ionization in the air at the rate of about 30,000 ion pairs per MeV of alpha energy. These charges can be transported over significant distances (several meters) in a moving current of air generated by a small fan. An ion chamber located in front of the fan measures the current carried by the moving ions. The LRAD-based monitor is more sensitive and more thorough than conventional monitors. We present current LRAD sensitivity limits and results, practical monitor designs, and proposed uses for LRAD monitors. 4 refs., 6 figs

  18. Contamination monitoring in radiation protection activities in Myanmar

    Energy Technology Data Exchange (ETDEWEB)

    Thin, K T; Htoon, S [Yangon Univ. (Myanmar). Dept. of Physics

    1997-06-01

    The radioactive contamination in rainwater, seawater, air, milk powder and other eatables were measured with low level counter assembly. The measured activities are found to be very low and well within the maximum permissible level. (author)

  19. Inspection and monitoring plan, contaminated groundwater seeps 317/319/ENE Area, Argonne National Laboratory

    International Nuclear Information System (INIS)

    1996-01-01

    During the course of completing the Resource Conservation and Recovery Act (RCRA) Facility Investigation (RFI) in the 317/319/East-Northeast (ENE) Area of Argonne National Laboratory-East (ANL-E), groundwater was discovered moving to the surface through a series of groundwater seeps. The seeps are located in a ravine approximately 600 ft south of the ANL-E fence line in Waterfall Glen Forest Preserve. Samples of the seep water were collected and analyzed for selected parameters. Two of the five seeps sampled were found to contain detectable levels of organic contaminants. Three chemical species were identified: chloroform (14--25 microg/L), carbon tetrachloride (56--340 microg/L), and tetrachloroethylene (3--6 microg/L). The other seeps did not contain detectable levels of volatile organics. The nature of the contaminants in the seeps will also be monitored on a regular basis. Samples of surface water flowing through the bottom of the ravine and groundwater emanating from the seeps will be collected and analyzed for chemical and radioactive constituents. The results of the routine sampling will be compared with the concentrations used in the risk assessment. If the concentrations exceed those used in the risk assessment, the risk calculations will be revised by using the higher numbers. This revised analysis will determine if additional actions are warranted

  20. Self-potential monitoring of a crude oil contaminated site (Trecate, Italy): first results of the modelling.

    Science.gov (United States)

    Giampaolo, V.; Rizzo, E.; Titov, K.; Maineult, A.; Lapenna, V.

    2012-04-01

    The contamination of soils and groundwater by hydrocarbon, due to blow out, leakage from tank or pipe and oil spill, is a heavy environmental problem because infiltrated oil can persist in the ground for a long time. The existing methods used for the remediation of these contaminated sites are invasive, time consuming and expensive. Therefore, in the last years, there was a growing interest in the use of geophysical methods for environmental monitoring (Atekwana et al., 2000; Chambers et al., 2004; Song et al., 2005; French et al., 2009). A particular attention is given to the self-potential (SP) method because SP is sensitive to the contaminant chemistry and redox processes generated by bacteria during the biodegradation (Atekwana et al., 2004; Naudet and Revil, 2005; Revil et al., 2010). Here we show the results of SP investigations carried out at Trecate site (Italy). This site was affected by a crude oil contamination from a well blowout in 1994. Four SP surveys (October 2009, March 2010, October 2010, and March 2011) were conducted at the site, both in the contaminated and uncontaminated regions. Significant changes are observed between SP data collected at different times. In particular, we found mostly negative electrical potential in October surveys and positive electrical potential in March surveys. The SP distributions can be interpreted as the superposition of many components, including a horizontal water-flow in the saturated shallow aquifer toward South-East, the infiltration movement of water in the unsaturated zone and, possibly, the oxidation-reduction phenomena due to bacterial activity. As the groundwater flow usually produces SP linear trends, the data were detrended by linear regression, taking into account the measured piezometric heads in the aquifer. The detrended SP data show that the SP distribution within the contaminated zone is generally bipolar in October: the southern part of the contaminated area is characterized by negative values

  1. Effects of arbuscular mycorrhizal inoculation on plants growing on arsenic contaminated soil.

    Science.gov (United States)

    Jankong, P; Visoottiviseth, P

    2008-07-01

    Arbuscular mycorrhizal fungi (AMF) may play an important role in phytoremediation of As-contaminated soil. In this study the effects of AMF (Glomus mosseae, Glomus intraradices and Glomus etunicatum) on biomass production and arsenic accumulation in Pityrogramma calomelanos, Tagetes erecta and Melastoma malabathricum were investigated. Soil (243 +/- 13 microg As g(-1)) collected from Ron Phibun District, an As-contaminated area in Thailand, was used in a greenhouse experiment. The results showed different effects of AMF on phytoremediation of As-contaminated soil by different plant species. For P. calomelanos and T. erecta, AMF reduced only arsenic accumulation in plants but had no significant effect on plant growth. In contrast, AMF improved growth and arsenic accumulation in M. malabathricum. These findings show the importance of understanding different interactions between AMF and their host plants for enhancing phytoremediation of As-contaminated soils.

  2. Modeling the migration of radioactive contaminants in groundwater of in situ leaching uranium mine

    International Nuclear Information System (INIS)

    Li Chunguang; Tai Kaixuan

    2011-01-01

    The radioactive contamination of groundwater from in situ leaching (ISL) of uranium mining is a widespread environmental problem. This paper analyzed the monitor results of groundwater contaminations for a in situ leaching uranium mine. A dynamic model of contaminants transport in groundwater in ISL well field was established. The processes and mechanisms of contaminant transport in groundwater were simulated numerically for a ISL well field. A small quantity of U and SO 4 2- migrate to outside of well field during ISL production stage. But the migration velocity and distance of contaminations is small, and the concentration is low. Contaminants migrate as anomalistic tooth-shape. The migration trend of U and SO 4 2- is consistent. Numerical modeling can provide an effective approach to analyse the transport mechanism, and forecast and control the migration of contaminants in groundwater in ISL well field. (authors)

  3. Petroleum-related contaminants near a produced water discharge site in the Santa Barbara Channel

    International Nuclear Information System (INIS)

    Jones, A.D.; Witter, A.E.; Higashi, R.M.

    1994-01-01

    Offshore oil production generates substantial quantities of waste water that is frequently discharged into marine waters. Contamination of coastal sediments occurs due to other inputs including natural petroleum seeps, and this complicates assessments of the environmental effects of produced water in marine ecosystems. The current study has focused on characterization of contaminants in sediments near produced water discharge site off the coast of Southern California. First, it was important to address the question: ''What contaminants in sediments should be monitored as indicators of produced water effects?'' Dichloromethane extracts of sediments were analyzed for numerous organic constituents using gas chromatography-mass spectrometry and selected ion monitoring. Though the phenols and fatty acids were not detected in sediment extracts, normal and branched alkanes and other petroleum hydrocarbon biomarkers were quantified. No relationship was evident that related absolute concentrations of organic compounds to distance from the outfall, but patterns of petroleum hydrocarbons exhibited consistent spatial variations that could be related to distance from the produced water out fall. Analysis of chemical fossil ''biomarkers'' provides potentially useful indices of effects of waste discharges upon microbial biodegradation of organic compounds in sediments

  4. The effect of compliance on contact lens case contamination.

    Science.gov (United States)

    Tilia, Daniel; Lazon de la Jara, Percy; Zhu, Hua; Naduvilath, Thomas J; Holden, Brien A

    2014-03-01

    To determine the efficacy of written instructions on contact lens case hygiene and to quantify the effect of noncompliance on contact lens case contamination. Data were retrospectively analyzed from 16 prospective, 3-month daily-wear studies during which six commercially available silicone hydrogel contact lenses and seven lens care solutions (LCS) were tested following a similar protocol. Verbal instructions regarding case hygiene (rinse case with LCS, not tap water) were given in nine studies, while the same instructions were given verbally and in written format in seven studies. A survey on contact lens, LCS, and lens case hygiene was completed at 1- and 3-month visits and compliance with case hygiene instructions was determined. Regular contact lens cases were used for 1 month and collected for microbial analysis at the 1- and 3-month visits. The rate of case contamination and the types of microbes contaminating cases were evaluated. Participants given verbal and written instructions were more likely to be compliant with case hygiene instructions than those just given verbal instructions (odds ratio [OR]: 2.19, p hygiene can be improved by effective communication of instructions. Contact lens wearers should be actively discouraged from rinsing contact lens cases with tap water because of the increased risk of GNB contamination.

  5. Erosion and Soil Contamination Control Using Coconut Flakes And Plantation Of Centella Asiatica And Chrysopogon Zizanioides

    Science.gov (United States)

    Roslan, Rasyikin; Che Omar, Rohayu; Nor Zuliana Baharuddin, Intan; Zulkarnain, M. S.; Hanafiah, M. I. M.

    2016-11-01

    Land degradation in Malaysia due to water erosion and water logging cause of loss of organic matter, biodiversity and slope instability but also land are contaminated with heavy metals. Various alternative such as physical remediation are use but it not showing the sustainability in term of environmental sustainable. Due to that, erosion and soil contamination control using coconut flakes and plantation of Centella asiatica and Chrysopogon zizanioides are use as alternative approach for aid of sophisticated green technology known as phytoremediation and mycoremediation. Soil from cabonaceous phyllite located near to Equine Park, Sri Kembangan are use for monitoring the effect of phytoremediation and mycoremediation in reducing soil contamination and biotechnology for erosion control. Five laboratory scale prototypes were designed to monitor the effect of different proportion of coconut flakes i.e. 10%, 25%, 50% & 100% and plantation of Centella asiatica and Chrysopogon zizanioides to reduce the top soil from eroding and reduce the soil contamination. Prototype have been observe started from first week and ends after 12 weeks. Centella asiatica planted on 10% coconut flakes with 90% soil and Chrysopogon zizanioides planted on 25% coconut flakes with 75% soil are selected proportion to be used as phytoremediation and mycoremediation in reducing soil contamination and biotechnology for erosion control.

  6. The Mobile Surface Contamination Monitor II environmental radiological characterization utilizing GPS/GIS technologies

    International Nuclear Information System (INIS)

    Wendling, M.A.

    1993-05-01

    Time, cost, and most importantly quality of data are the three factors to measure the success of field radiological characterizations. The application of coupling radiation detection instrumentation to a GPS receiver has dramatically increased the data quality achievable compared to traditional environmental radiological survey methods. Improvements in verifying adequate spatial coverage of an area while collecting data and at,the same time reducing field time requirements can be realized. Data acquired during the recent implementation of the Mobile Surface Contamination Monitor 11 (MSCM-11) will be presented to demonstrate the advantages of this system over traditional radiological survey methods. The comparison will include time and manpower requirements. Linking the complimentary GPS, GIS and radiation detection technologies on a mobile tractor based platform has provided a tool to provide radiological characterization data faster, cheaper, and better to assist in the Environmental Restoration Mission of the Hanford Site

  7. Numerical Study of Contaminant Effects on Combustion of Hydrogen, Ethane, and Methane in Air

    Science.gov (United States)

    Lai, H. T.; Thomas, S. R.

    1995-01-01

    A numerical study was performed to assess the effects of vitiated air on the chemical kinetics of hydrogen, ethane, and methane combustion with air. A series of calculations in static reacting systems was performed, where the initial temperature was specified and reactions occurred at constant pressure. Three different types of test flow contaminants were considered: NP, H2O, and a combustion of H2O and CO2. These contaminants are present in the test flows of facilities used for hypersonic propulsion testing. The results were computed using a detailed reaction mechanism and are presented in terms of ignition and reaction times. Calculations were made for a wide range of contaminant concentrations, temperatures and pressures. The results indicate a pronounced kinetic effect over a range of temperatures, especially with NO contamination and, to a lesser degree, with H2O contamination. In all cases studied, CO2 remained kinetically inert, but had a thermodynamic effect on results by acting as a third body. The largest effect is observed with combustion using hydrogen fuel, less effect is seen with combustion of ethane, and little effect of contaminants is shown with methane combustion.

  8. Lyophilization of a triply unsaturated phospholipid: Effects of trace metal contaminants

    Science.gov (United States)

    Payton, N.M.; Wempe, M.F.; Betker, Jamie L.; Randolph, T.W.; Anchordoquy, T.J.

    2013-01-01

    As liquid liposomal formulations are prone to chemical degradation and aggregation, these formulations often require freeze drying (e.g. lyophilization) to achieve sufficient shelf-life. However, liposomal formulations may undergo oxidation during lyophilization and/or during prolonged storage. The goal of the current study was to characterize the degradation of 1, 2-dilinolenoyl-sn-glycero-3-phosphocholine (DLPC) during lyophilization, and to also probe the influence of metal contaminants in promoting the observed degradation. Aqueous sugar formulations containing DLPC (0.01 mg/ml) were lyophilized, and DLPC degradation was monitored using HPLC/UV and GC/MS methods. The effect of ferrous ion and sucrose concentration, as well as lyophilization stage promoting lipid degradation, was investigated. DLPC degradation increased with higher levels of ferrous ion. After lyophilization, 103.1% ± 1.1%, 66.9% ± 0.8%, and 28.7% ± 0.7% DLPC remained in the sucrose samples spiked with 0.0 ppm, 0.2 ppm and 1.0 ppm ferrous ion, respectively. Lipid degradation predominantly occurs during the freezing stage of lyophilization. Sugar concentration and buffer ionic strength also influence the extent of lipid degradation, and DLPC loss correlated with degradation product formation. We conclude that DLPC oxidation during the freezing stage of lyophilization dramatically compromises the stability of lipid-based formulations. In addition, we demonstrate that metal contaminants in sugars can become highly active when lyophilized in the presence of a reducing agent. PMID:23567484

  9. Allee effect in polar bears: a potential consequence of polychlorinated biphenyl contamination.

    Science.gov (United States)

    Pavlova, Viola; Nabe-Nielsen, Jacob; Dietz, Rune; Sonne, Christian; Grimm, Volker

    2016-11-30

    Polar bears (Ursus maritimus) from East Greenland and Svalbard exhibited very high concentrations of polychlorinated biphenyls (PCBs) in the 1980s and 1990s. In Svalbard, slow population growth during that period was suspected to be linked to PCB contamination. In this case study, we explored how PCBs could have impacted polar bear population growth and/or male reproductive success in Svalbard during the mid-1990s by reducing the fertility of contaminated males. A dose-response relationship linking the effects of PCBs to male polar bear fertility was extrapolated from studies of the effects of PCBs on sperm quality in rodents. Based on this relationship, an individual-based model of bear interactions during the breeding season predicted fertilization success under alternative assumptions regarding male-male competition for females. Contamination reduced pregnancy rates by decreasing the availability of fertile males, thus triggering a mate-finding Allee effect, particularly when male-male competition for females was limited or when infertile males were able to compete with fertile males for females. Comparisons of our model predictions on age-dependent reproductive success of males with published empirical observations revealed that the low representation of 10-14-year-old males among breeding males documented in Svalbard in mid-1990s could have resulted from PCB contamination. We conclude that contamination-related male infertility may lead to a reduction in population growth via an Allee effect. The magnitude of the effect is largely dependent on the population-specific mating system. In eco-toxicological risk assessments, appropriate consideration should therefore be given to negative effects of contaminants on male fertility and male mating behaviour. © 2016 The Author(s).

  10. Mussels as bioindicators of diclofenac contamination in coastal environments.

    Science.gov (United States)

    Cunha, S C; Pena, A; Fernandes, J O

    2017-06-01

    Diclofenac a nonsteroidal anti-inflammatory drug (NSAID) has been confirmed as an emerging contaminant in the aquatic environment. Toxicology studies have revealed that harmful effects may emerge from diclofenac presence not only for human health, but also for marine organisms, which implies its monitoring. To overcome the demanding challenges of diclofenac quantification in biotic aquatic species, a novel method for the determination of diclofenac in mussels (Mytilus galloprovincialis and Mytilus edulis) and macroalgae (Laminaria digitata) using high performance liquid chromatography coupled to tandem mass spectrometry was developed and validated according to the EC Decision 2002/657/EC. Additionally, a study was done about diclofenac contamination in mussels collected from 8 sites along the 1115 miles of coastline in Portugal in 2015. The results suggested that levels in mussels are closely related to the environmental contamination. Therefore, mussels can be a potential bioindicator of diclofenac contamination in the coastal environment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. SIMON: A mobile robot for floor contamination surveys

    International Nuclear Information System (INIS)

    Dudar, E.; Teese, G.; Wagner, D.

    1991-01-01

    The Robotics Development group at the Savannah River Site is developing an autonomous robot to perform radiological surveys of potentially contaminated floors. The robot scans floors at a speed of one-inch/second and stops, sounds an alarm, and flashes lights when contamination in a certain area is detected. The contamination of interest here is primarily alpha and beta-gamma. The contamination levels are low to moderate. The robot, a Cybermotion K2A, is radio controlled, uses dead reckoning to determine vehicle position, and docks with a charging station to replenish its batteries and calibrate its position. It has an ultrasonic collision avoidance system as well as two safety bumpers that will stop the robot's motion when they are depressed. Paths for the robot are preprogrammed and the robot's motion can be monitored on a remote screen which shows a graphical map of the environment. The radiation instrument being used is an Eberline RM22A monitor. This monitor is microcomputer based with a serial I/O interface for remote operation. Up to 30 detectors may be configured with the RM22A. For our purposes, two downward-facing gas proportional detectors are used to scan floors, and one upward-facing detector is used for radiation background compensation. SIMON is interfaced with the RM22A in such a way that it scans the floor surface at one-inch/second, and if contamination is detected, the vehicle stops, alarms, and activates a voice synthesizer. Future development includes using the contamination data collected to provide a graphical contour map of a contaminated area. 3 refs

  12. Sampling of suspended particulate matter using particle traps in the Rhône River: Relevance and representativeness for the monitoring of contaminants.

    Science.gov (United States)

    Masson, M; Angot, H; Le Bescond, C; Launay, M; Dabrin, A; Miège, C; Le Coz, J; Coquery, M

    2018-05-10

    Monitoring hydrophobic contaminants in surface freshwaters requires measuring contaminant concentrations in the particulate fraction (sediment or suspended particulate matter, SPM) of the water column. Particle traps (PTs) have been recently developed to sample SPM as cost-efficient, easy to operate and time-integrative tools. But the representativeness of SPM collected with PTs is not fully understood, notably in terms of grain size distribution and particulate organic carbon (POC) content, which could both skew particulate contaminant concentrations. The aim of this study was to evaluate the representativeness of SPM characteristics (i.e. grain size distribution and POC content) and associated contaminants (i.e. polychlorinated biphenyls, PCBs; mercury, Hg) in samples collected in a large river using PTs for differing hydrological conditions. Samples collected using PTs (n = 74) were compared with samples collected during the same time period by continuous flow centrifugation (CFC). The grain size distribution of PT samples shifted with increasing water discharge: the proportion of very fine silts (2-6 μm) decreased while that of coarse silts (27-74 μm) increased. Regardless of water discharge, POC contents were different likely due to integration by PT of high POC-content phytoplankton blooms or low POC-content flood events. Differences in PCBs and Hg concentrations were usually within the range of analytical uncertainties and could not be related to grain size or POC content shifts. Occasional Hg-enriched inputs may have led to higher Hg concentrations in a few PT samples (n = 4) which highlights the time-integrative capacity of the PTs. The differences of annual Hg and PCB fluxes calculated either from PT samples or CFC samples were generally below 20%. Despite some inherent limitations (e.g. grain size distribution bias), our findings suggest that PT sampling is a valuable technique to assess reliable spatial and temporal trends of particulate

  13. Verification of radioactive contamination surveys for practical use in biological research centres

    International Nuclear Information System (INIS)

    Macias, M.T.; Requejo, C.; Ruiz, M.; Pina, R.

    2006-01-01

    Unsealed sources are commonly used in science research laboratories. Their manipulation may imply a radioactive contamination hazard. Therefore, adequate and sensitive survey meters must be available, and must have an effective and accurate response to intensity and type of radiation emitted by the used radionuclides to identify and quantify the possible contamination and then be able to avoid any associated or unwanted consequences that may arise. Periodic surveys are performed to show control, any time, any place radioactive contamination is suspected, and to ensure radioisotopes are being used safely. The immediate work areas must be often checked with portable survey monitors, including the entire lab and particularly bench tops, personnel protective equipment or solely designated equipment for isotope use (micro-fuges, water baths, incubators). These are carried out with portable survey instruments like Geiger-Muller tubes, proportional counters and scintillation detectors that provide direct or indirect measurements capabilities. The Radiation Safety Office (R.S.O.) as well as the radioactive compounds working laboratories at the Instituto de Inv. Biomedicas 'A. Sols' (Madrid-Spain) are provided with an adequate radiation measurement instrument. But, before a portable survey instrument is used, several quality checks should be made (batteries, calibration sticker), and the instrument response should be tested with a check source. This paper aims at determining, with a R.S.O. procedure, these surveys working parameters -detection efficiency, calibration factors and minimum detectable activities-, using reference checking sources ( 14 C, 36 Cl, and 90 Sr/ 90 Y) with known radioactivity covering the energy range of beta emitting isotopes used in biological research. No gamma portable monitors have been tested for the R.S.O. has no gamma checking sources. Therefore, 58 beta monitors were tested, obtaining t he efficiency values, the calibration factors (Bq cm-2 s

  14. Experience during the monitoring of inactive scrap for the detection of inadvertent presence of radioactivity

    International Nuclear Information System (INIS)

    Sharma, Ranjit; Kumar, Anoj; Vikas; Patra, R.P.; Kumar, Vikas; Singh, Rajvir; Pradeepkumar, K.S.

    2012-01-01

    The inspection and certification of scrap material from nuclear facilities is a regulatory requirement to ensure that radioactive material will not reach public domain. Around the world, cases involving radioactive contamination of metallic components have occurred due to radioactive sources/contaminated metal scrap reaching the public domain. Radiological monitoring of inactive scrap material is essential as it may get into various usages in public domain where controls cannot be implemented. The method of detection is measurement of gamma dose rates due to any loose/fixed radioactive contamination in the scrap or presence of any radioactive material/source. In addition prevention of any inadvertent/malicious act leading to radioactive material reaching the public domain through scrap being essential, this monitoring gains further importance. This paper describes the methodology and experience in detection of presence of radioactivity at inactive Scrap monitoring facility. Even though radioactive sources of high strength with potential for serious environmental hazard have not been detected, few cases of contaminated material (MS plate/equipments etc with extremely low level of 137 Cs and Uranium contamination) have been detected and identified using portable gamma spectrometer. If proper monitoring is not carried out the dispersal of radioactivity to the environment can be a matter of concern due to metal scrap reaching recycling industry resulting in huge cost of decontamination and waste disposal. These events may also have negative impact on the export from the country resulting in economic losses. The impact of such events can be ruled out by effective scrap monitoring techniques which ensure that even small quantity of radioactivity escaping into public domain can be prevented. The methodology followed for monitoring of inactive scrap is found to be effective even for detection of presence of very low level of radioactivity

  15. ACTIVE CAPPING TECHNOLOGY - NEW APPROACHES FOR IN SITU REMEDIATION OF CONTAMINATED SEDIMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Knox, A.; Paller, M.; Roberts, J.

    2012-02-13

    This study evaluated pilot-scale active caps composed of apatite, organoclay, biopolymers, and sand for the remediation of metal-contaminated sediments. The active caps were constructed in Steel Creek, at the Savannah River Site near Aiken, South Carolina. Monitoring was conducted for 12 months. Effectiveness of the caps was based on an evaluation of contaminant bioavailability, resistance to erosion, and impacts on benthic organisms. Active caps lowered metal bioavailability in the sediment during the one-year test period. Biopolymers reduced sediment suspension during cap construction, increased the pool of carbon, and lowered the release of metals. This field validation showed that active caps can effectively treat contaminants by changing their speciation, and that caps can be constructed to include more than one type of amendment to achieve multiple goals.

  16. Beyond the bed: Effects of metal contamination on recruitment to bedded sediments and overlying substrata

    International Nuclear Information System (INIS)

    Hill, Nicole A.; Simpson, Stuart L.; Johnston, Emma L.

    2013-01-01

    Metal-contaminated sediments pose a recognised threat to sediment-dwelling fauna. Re-mobilisation of contaminated sediments however, may impact more broadly on benthic ecosystems, including on diverse assemblages living on hard substrata patches immediately above sediments. We used manipulative field experiments to simultaneously test for the effects of metal contamination on recruitment to marine sediments and overlying hard substrata. Recruitment to sediments was strongly and negatively affected by metal contamination. However, while assemblage-level effects on hard-substratum fauna and flora were observed, most functional groups were unaffected or slightly enhanced by exposure to contaminated sediments. Diversity of hard-substratum fauna was also enhanced by metal contamination at one site. Metal-contaminated sediments appear to pose less of a hazard to hard-substratum than sediment-dwelling assemblages, perhaps due to a lower direct contaminant exposure or to indirect effects mediated by contaminant impacts on sediment fauna. Our results indicate that current sediment quality guidelines are protective of hard-substrata organisms. - Highlights: ► Potential for contaminated sediments to exert impacts beyond the sediment communities. ► We examine effects on recruitment to sediments and overlying hard substrata simultaneously. ► Metal-contaminated sediments had a strong negative impact on sediment fauna. ► Metal-contaminated sediments pose less of a hazard to hard-substratum fauna. ► Sediment quality guidelines are likely protective of hard-substrata organisms. - Under natural disturbance regimes, metal-contaminated sediments pose less of a direct risk to hard-substratum fauna than to sediment-dwelling fauna and SQG appear appropriate.

  17. Cuban-Brazilian comparison of the calibration procedures for surface contamination monitors

    International Nuclear Information System (INIS)

    Salas, Gonzalo W.; Garcia, Jose A.T.; Ramos, Manoel M.O.

    2007-01-01

    The calibration laboratory of the CPHR, Centro de Proteccion e Higiene de las Radiaciones, is the only laboratory that performs calibrations of radiation protection instruments in Cuba. Recently they started a cooperation project with IAEA, code number CUB3002-01 with the task title 'Assuring and Demonstrating the safety of radioactive Waste Management'. Within the frame of this project they have a compromise to implement the calibration service for surface contamination monitors, for which they received instruments and sources. In 2006 the Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI) from the Instituto de Radioprotecao e Dosimetria, IRD/CNEN, was invited to perform a mission to CPHR in order to evaluate the level of implementation of the service trough the insertion of the service in the Quality Assurance System of their laboratory, and perform a comparison exercise to test the calibration method implemented. The results were evaluated by the methodology recommended in the ISO/IEC 43-1 standard. These results show that all values from both laboratories are comparable for most radionuclides except for Cl-36. The preliminary investigation about this situation is presented in the paper. (author)

  18. Natural uranium toxicology - evaluation of internal contamination in man

    International Nuclear Information System (INIS)

    Chalabreysse, J.

    1968-01-01

    After reminding the physical and chemical properties of natural uranium which might affect its toxicology, a comprehensive investigation upon natural uranium metabolism and toxicity and after applying occupational exposure standards to this particular poison, it has been determined, from accident reports and human experience reported in the related literature, a series of formulae obtained by theoretical mathematical development giving principles for internal contamination monitoring and disclosure by determining uranium in the urine of occupationally exposed individuals. An assay is performed to determine individual internal contamination according to the various contamination cases. The outlined purposes, mainly practical, required some options and extrapolations. The proposed formula allows a preliminary approach and also to determine shortly a contamination extent or to discuss the systematical urinalysis results as compared with individual radio-toxicology monitoring professional standards. (author) [fr

  19. TECHNICAL BASIS FOR EVALUATING SURFACE BARRIERS TO PROTECT GROUNDWATER FROM DEEP VADOSE ZONE CONTAMINATION

    International Nuclear Information System (INIS)

    Fayer, J.M.; Freedman, V.L.; Ward, A.L.; Chronister, G.B.

    2010-01-01

    The U.S. DOE and its predecessors released nearly 2 trillion liters (450 billion gallons) of contaminated liquid into the vadose zone at the Hanford Site. Some of the contaminants currently reside in the deeper parts of the vadose zone where they are much less accessible to characterization, monitoring, and typical remediation activities. The DOE Richland Operations Office (DOE-RL) prepared a treatability test plan in 2008 to examine remediation options for addressing contaminants in the deep vadose zone; one of the technologies identified was surface barriers (also known as engineered barriers, covers, and caps). In the typical configuration, the contaminants are located relatively close to the surface, generally within 15 m, and thus they are close to the base of the surface barrier. The proximity of the surface barrier under these conditions yielded few concerns about the effectiveness of the barrier at depth, particularly for cases in which the contaminants were in a lined facility. At Hanford, however, some unlined sites have contaminants located well below depths of 15 m. The issue raised about these sites is the degree of effectiveness of a surface barrier in isolating contaminants in the deep vadose zone. Previous studies by Hanford Site and PNNL researchers suggest that surface barriers have the potential to provide a significant degree of isolation of deep vadose zone contaminants. The studies show that the actual degree of isolation is site-specific and depends on many factors, including recharge rates, barrier size, depth of contaminants, geohydrologic properties ofthe sediments, and the geochemical interactions between the contaminants and the sediments. After the DOE-RL treatability test plan was published, Pacific Northwest National Laboratory was contracted to review the information available to support surface barrier evaluation for the deep vadose zone, identify gaps in the information and outcomes necessary to fill the data gaps, and outline

  20. Aquatic mosses as a monitoring tool for 137Cs contamination in streams and rivers--a field study from central southern Norway

    International Nuclear Information System (INIS)

    Hongve, D.; Brittain, J.E.; Bjoernstad, H.E.

    2002-01-01

    Mosses are frequently used as biomonitors for trace element pollution in the aquatic environment. The purpose of this study was to assess their usefulness as a tool in monitoring and in regional surveys of radioactive contamination. Specimens of the aquatic mosses, Fontinalis antipyretica and F. dalecarlica, were transplanted from non-contaminated areas to streams and rivers in the Norwegian Jotunheimen Mountains and neighbouring lowland areas that had received radioactive fallout after the Chernobyl accident. Equilibrium concentrations of 137 Cs in the exposed mosses were reached after a few weeks. Two series from 20 streams in 1994 and 1996 show linear correlations between activities in water and moss samples and biomagnification ratios of 10 4 -10 5 . We conclude that mosses are better suited for monitoring purposes than water samples, because they provide values integrated over weeks while the radioactivity in surface waters can be subject to rapid variations according to hydrological events. The activity concentrations in aquatic mosses can be easily measured with good precision even when aqueous concentrations are below the limit of detection. Use of aquatic mosses also reduces the logistic problems of transporting large volumes of water, especially in areas inaccessible by road

  1. A potential approach for monitoring drinking water quality from groundwater systems using organic matter fluorescence as an early warning for contamination events

    DEFF Research Database (Denmark)

    Stedmon, Colin; Seredyńska-Sobecka, Bożena; Boe-Hansen, Rasmus

    2011-01-01

    at levels equivalent to the addition of 60 μg C/L in drinking water with a TOC concentration of 3.3 mg C/L. The results of this study suggest that these types of drinking water systems, which are vulnerable to microbial contamination due to the lack of disinfectant treatment, can be easily monitored using...

  2. Application of hazard analysis critical control points (HACCP) to organic chemical contaminants in food.

    Science.gov (United States)

    Ropkins, K; Beck, A J

    2002-03-01

    Hazard Analysis Critical Control Points (HACCP) is a systematic approach to the identification, assessment, and control of hazards that was developed as an effective alternative to conventional end-point analysis to control food safety. It has been described as the most effective means of controlling foodborne diseases, and its application to the control of microbiological hazards has been accepted internationally. By contrast, relatively little has been reported relating to the potential use of HACCP, or HACCP-like procedures, to control chemical contaminants of food. This article presents an overview of the implementation of HACCP and discusses its application to the control of organic chemical contaminants in the food chain. Although this is likely to result in many of the advantages previously identified for microbiological HACCP, that is, more effective, efficient, and economical hazard management, a number of areas are identified that require further research and development. These include: (1) a need to refine the methods of chemical contaminant identification and risk assessment employed, (2) develop more cost-effective monitoring and control methods for routine chemical contaminant surveillance of food, and (3) improve the effectiveness of process optimization for the control of chemical contaminants in food.

  3. New ICPP portal monitor

    International Nuclear Information System (INIS)

    Georgeson, M.A.; Nichols, C.E.

    1981-04-01

    A large area gas filled proportional-detector portal monitor mounted in a swinging door frame has been designed and developed at the Idaho Chemical Processing Plant (ICPP). This monitor extends the sensitivity and speed of personnel contamination detection to levels equal to or exceeding that obtained using hand-held portable survey techniques. The new monitor has state-of-the-art electronics which result in rapid response, and use statistical principles in the alarm logic to reduce or eliminate spurious alarms. In addition, the evaluation of this instrument indicates that it will detect small enough quantities of U-235 in shielded containers to meet current special nuclear materials (SNM) detection standards. Simultaneous detection of very low level contamination and small quantities of SNM results in a monitor particularly useful for nuclear installations

  4. IN-SITU, LONG-TERM MONITORING SYSTEM FOR RADIOACTIVE CONTAMINANTS

    International Nuclear Information System (INIS)

    Durham, James S.; McKeever, Stephen W.S.; Akselrod, Mark S.

    2002-01-01

    This report presents the results of the first phase of the project entitled ''In-situ, Long-term Monitoring System for Radioactive Contaminants.'' Phase one of this effort included four objectives, each with specific success criteria. The first objective was to produce dosimetry grade fibers and rods of aluminum oxide. The success criterion for this milestone was the production of aluminum oxide rods and fibers that have a minimum measurable dose (MMD) of 100 mrem or less. This milestone was completed and the MMD for the rods was measured to be 1.53 mrem. Based on the MMD, the ability of the sensor to measure 137 Cs, 90 Sr/ 90 Y, and 99 Tc was evaluated. It was determined that the sensor can measure the release limit of these radionuclides (50 pCi/cm 3 ) in 150 h, 200 h, and 54,000 h, respectively. The monitor is adequate for measuring 137 Cs and 90 Sr/ 90 Y but is unsuitable for measuring 99 Tc in soil. The second objective was to construct a prototype sensor (dosimeter and fiber optic channel). There were three success criteria for this milestone: (1) Perform measurements with the sensor for both gamma and beta radiation with a standard deviation of 10% or less; (2) Demonstrate the ability of the sensor to discriminate between gamma and beta radiation; and (3) Obtain similar or relatable results for differing lengths of fiber optic cable. These milestones were met. The sensor was able to measure gamma radiation repeatedly with a standard deviation of 3.15% and beta radiation with a standard deviation of 2.85%. Data is presented that demonstrates that an end cap can be used to discriminate between beta plus gamma radiation using beta radiation from a 90 Sr/ 90 Y source, and gamma radiation alone. It is shown that some amount of attenuation occurs in longer fiber optic cables, but it is unclear if the attenuation is due to poor alignment of the dosimeter and the cable. This issue will be investigated further when more dosimeters are available so that the dosimeters

  5. IN-SITU, LONG-TERM MONITORING SYSTEM FOR RADIOACTIVE CONTAMINANTS

    International Nuclear Information System (INIS)

    Durham, James S.; McKeever, Stephen W.S.; Akselrod, Mark S.

    2002-01-01

    This report presents the results of the first phase of the project entitled ''In-situ, Long-term Monitoring System for Radioactive Contaminants.'' Phase one of this effort included four objectives, each with specific success criteria. The first objective was to produce dosimetry grade fibers and rods of aluminum oxide. The success criterion for this milestone was the production of aluminum oxide rods and fibers that have a minimum measureable dose (MMD) of 100 mrem or less. This milestone was completed and the MMD for the rods was measured to be 1.53 mrem. Based on the MMD, the ability of the sensor to measure 137 Cs, 90 Sr/ 90 Y, and 99 Tc was evaluated. It was determined that the sensor can measure the release limit of these radionuclides (50 pCi/cm 3 ) in 150 h, 200 h, and 54,000 h, respectively. The monitor is adequate for measuring 137 Cs and 90 Sr/ 90 Y but is unsuitable for measuring 99 Tc in soil. The second objective was to construct a prototype sensor (dosimeter and fiber optic channel). There were three success criteria for this milestone: (1) Perform measurements with the sensor for both gamma and beta radiation with a standard deviation of 10% or less; (2) Demonstrate the ability of the sensor to discriminate between gamma and beta radiation; and (3) Obtain similar or relatable results for differing lengths of fiber optic cable. These milestones were met. The sensor was able to measure gamma radiation repeatedly with a standard deviation of 3.15% and beta radiation with a standard deviation of 2.85%. Data is presented that demonstrates that an end cap can be used to discriminate between beta plus gamma and gamma radiation. It is shown that some amount of attenuation occurs in longer fiber optic cables, but it is unclear if the attenuation is due to poor alignment of the dosimeter and the cable. This issue will be investigated further when more dosimeters are available so that the dosimeters can be permanently attached to the longer cables. The third

  6. Pharmaceutical products as emerging contaminant in water: relevance for developing nations and identification of critical compounds for Indian environment.

    Science.gov (United States)

    Chinnaiyan, Prakash; Thampi, Santosh G; Kumar, Mathava; Mini, K M

    2018-04-17

    Pharmaceuticals and personal care products (PPCPs) are contaminants of emerging concern and have been detected worldwide in water bodies in trace concentrations. Most of these emerging contaminants are not regulated in water quality standards except a few in the developed countries. In the case of developing countries, research in this direction is at a nascent stage. For the effective management of Pharmaceutical contaminants (PC) in developing countries, the relevance of PCs as an emerging contaminant has to be analyzed followed by regular monitoring of the environment. Considering the resource constraints, this could be accomplished by identifying the priority compounds which is again region specific and dependent on consumption behavior and pattern. In this work, relevance of pharmaceutical compound as emerging contaminant in water for a developing country like India is examined by considering the data pertaining to pharmaceutical consumption data. To identify the critical Pharmaceutical Contaminants to be monitored in the Indian environment, priority compounds from selected prioritization methods were screened with the compounds listed in National List of Essential Medicine (NLEM), India. Further, information on the number of publications on the compound as an emerging contaminant, data on monitoring studies in India and the number of brands marketing the compound in India were also analyzed. It is found that out of 195 compounds from different prioritization techniques, only 77 compounds were found relevant to India based on NLEM sorting.

  7. A low cost mid-infrared sensor for on line contamination monitoring of lubricating oils in marine engines

    Science.gov (United States)

    Ben Mohammadi, L.; Kullmann, F.; Holzki, M.; Sigloch, S.; Klotzbuecher, T.; Spiesen, J.; Tommingas, T.; Weismann, P.; Kimber, G.

    2010-04-01

    The chemical and physical condition of oils in marine engines must be monitored to ensure optimum performance of the engine and to avoid damage by degraded oil not adequately lubricating the engine. Routine monitoring requires expensive laboratory testing and highly skilled analysts. This work describes the adaptation and implementation of a mid infrared (MIR) sensor module for continued oil condition monitoring in two-stroke and four-stroke diesel engines. The developed sensor module will help to reduce costs in oil analysis by eliminating the need to collect and send samples to a laboratory for analysis. The online MIR-Sensor module measures the contamination of oil with water, soot, as well as the degradation indicated by the TBN (Total Base Number) value. For the analysis of water, TBN, and soot in marine engine oils, four spectral regions of interest have been identified. The optical absorption in these bands correlating with the contaminations is measured simultaneously by using a four-field thermopile detector, combined with appropriate bandpass filters. Recording of the MIR-absorption was performed in a transmission mode using a flow-through cell with appropriate path length. Since in this case no spectrometer is required, the sensor including the light source, the flowthrough- cell, and the detector can be realised at low cost and in a very compact manner. The optical configuration of the sensor with minimal component number and signal intensity optimisation at the four-field detector was implemented by using non-sequential ray tracing simulation. The used calibration model was robust enough to predict accurately the value for soot, water, and TBN concentration for two-stroke and four-stroke engine oils. The sensor device is designed for direct installation on the host engine or machine and, therefore, becoming an integral part of the lubrication system. It can also be used as a portable stand-alone system for machine fluid analysis in the field.

  8. Light contamination

    International Nuclear Information System (INIS)

    Cepeda Pena, William Enrique

    1998-01-01

    The article tries on the wrong use of the artificial light, of the main problems of the light contamination, dispersion of the light, noxious effects of the light contamination, ecological effects, effects on the man's biological rhythm, economic effects and effects about the civic and vial security, among other topics

  9. Improved management of winter operations to limit subsurface contamination with degradable deicing chemicals in cold regions.

    Science.gov (United States)

    French, Helen K; van der Zee, Sjoerd E A T M

    2014-01-01

    This paper gives an overview of management considerations required for better control of deicing chemicals in the unsaturated zone at sites with winter maintenance operations in cold regions. Degradable organic deicing chemicals are the main focus. The importance of the heterogeneity of both the infiltration process, due to frozen ground and snow melt including the contact between the melting snow cover and the soil, and unsaturated flow is emphasised. In this paper, the applicability of geophysical methods for characterising soil heterogeneity is considered, aimed at modelling and monitoring changes in contamination. To deal with heterogeneity, a stochastic modelling framework may be appropriate, emphasizing the more robust spatial and temporal moments. Examples of a combination of different field techniques for measuring subsoil properties and monitoring contaminants and integration through transport modelling are provided by the SoilCAM project and previous work. Commonly, the results of flow and contaminant fate modelling are quite detailed and complex and require post-processing before communication and advising stakeholders. The managers' perspectives with respect to monitoring strategies and challenges still unresolved have been analysed with basis in experience with research collaboration with one of the case study sites, Oslo airport, Gardermoen, Norway. Both scientific challenges of monitoring subsoil contaminants in cold regions and the effective interaction between investigators and management are illustrated.

  10. Water-quality monitoring at the Hoe Creek test site: review and preliminary conclusions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, F T; Mead, S W; Stuermer, D H

    1982-05-20

    It has been shown that underground coal gasification (UCG) may introduce a broad range of residual gasification products into the groundwater of a coal aquifer. Sorption of many contaminants by the coal itself is an important factor in restricting the migration of these contaminants in the ground water. However, field studies, conducted at Lawrence Livermore National Laboratory's Hoe Creek site, have shown that sorption of organic compounds by coal is not as effective as expected, perhaps because the coal surface area is limited. Furthermore, if severe roof collapse has taken place during gasification, non-coal aquifers located above the gasified coal seam may be interconnected with the coal aquifer, and contaminants may enter these non-coal aquifers, in which sorption is even less effective. The Hoe Creek II and III experiments have provided opportunities to study the contamination of a sand aquifer located above a gasified coal seam in a hydrological recharge area. Preliminary results indicate that the water in the overlying sand aquifer is much less contaminated with organic compounds than the water in the gasified coal aquifer. In conducting these field investigations, valuable lessons ere learned concerning groundwater monitoring. A suggested monitoring strategy is discussed.

  11. Clean Slate 1 revegetation and monitoring plan

    International Nuclear Information System (INIS)

    Anderson, D.C.; Hall, D.B.

    1997-07-01

    This document constitutes a reclamation plan for the short-term and long-term stabilization of land disturbed by activities associated with the cleanup of radionuclide contaminated surface soil at the Clean Slate 1 site. This document has been prepared to provide general reclamation practices and procedures that will be followed during restoration of the cleanup site. The results of reclamation trials at Area 11, Area 19 and more recently the reclamation demonstration plots at the Double Tracks cleanup site, have been summarized and incorporated into this reclamation and monitoring plan. The plan also contains procedures for monitoring both the effectiveness and success of short-term and long-term soil stabilization. The Clean Slate 1 site is located on the Tonopah Test Range. The surface soils were contaminated as a result of the detonation of a device containing plutonium and depleted uranium using chemical explosives. Short-term stabilization consists of the application of a chemical soil stabilizer that is applied immediately following excavation of the contaminated soils to minimize Pu resuspension. Long-term stabilization is accomplished by the establishment of a permanent vegetation

  12. Application of diagnosis and monitoring area contaminated by petroleum derivatives; Aplicacao da tecnica de caminhamento eletrico em area contaminada por derivados de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Cesar Augusto [Pos-graduacao em Geociencias em Meio Ambiente, IGCE - UNESP, Rio Claro, SP (Brazil)], E-mail: cesargeologia@yahoo.com.br; Dourado, Joao Carlos; Braga, Antonio Celso de Oliveira [Dept. de Geologia Aplicada, IGCE - UNESP, Rio Claro, SP (Brazil)], E-mails: jdourado@rc.unesp.br, acobraga@rc.unesp.br

    2006-07-15

    Geophysical methods are useful technic of geological investigation, thoroughly employed to diagnosis and monitoring contaminated areas, in conjunction with direct techniques of investigation such as chemical analyses. Among these, electric resistivity is more usually used in studies of contaminants in soil and groundwater, due to the high contrast of electric properties between the soil and the pollutant types frequently found, essentially constituted of composed organic and inorganic. Geophysical studies in impacted areas by petroleum products may be describe by anomalies of both low resistivity and high resistivities, confirmed as contaminant by chemical analyses. This apparent contradiction can reflect processes of degradation of the contaminants, directly associated with its residence time in the soil, through the generation of by-products that change the physical properties of the soil and groundwater, principally for the mineral dissolution by action of organic acids and by formation of minerals of oxides and hydroxides minerals. Natural attenuation defines a series of physical, chemical and biological processes that allow the degradation, dispersion and dilution of contaminants in a natural form, in other words, free from human intervention. This paper presents the application of electrical profiling technique in a contaminated industrial area for benzene, toluene, xylene, 1,2 dichloroethene and inorganic salts and it discusses the physical alterations of the contaminated soil through the obtained results, under the optics of the Natural Attenuation in course in the area of study. (author)

  13. 4. International Symposium and Exhibition on Environmental Contamination in Central and Eastern Europe. Symposium Program

    International Nuclear Information System (INIS)

    1998-01-01

    The Fourth International Symposium and Exhibition on Environmental Contamination in Central and Eastern Europe was part of an on-going series of symposia which focus on the environmental problems of Central and Eastern Europe. The presentations concerned radiological contamination, hazardous waste management, environmental monitoring, modeling and computer applications for environmental studies, site remediation. Many works presented human health effects of environmental pollution by heavy metals, radionuclides and other xenobiotics

  14. Design and development of food radioactivity contamination monitoring system

    International Nuclear Information System (INIS)

    Narayan, Pradeep; Vaijapurkar, S.G.; Bohra, Dinesh

    2014-01-01

    Radioactivity has been part and parcel of living being since the existence of the earth. It is available everywhere in our environment and being responsible for evolution of life on earth at some extent. However, the radioactivity in excess of the natural radioactive can have harmful effects on living being. The radiation exposure can be of external or internal origin or of both. The main route of internal radiation exposure is through the contaminated food chains. The concentration of natural radioactivity in food varies in range of 40-600 Bq/kg. 40 K being the single major radionuclide of food with typical radioactivity; 50 Bq/kg in milk, 420 Bq/kg in milk powder, 165 Bq/kg in potatoes, and 125 Bq/kg in beef is also the main contributor of natural radiation doses to human being. Measurement of radioactivity in food items and drinks is thus very important in controlling the internal exposure to human being especially in case of nuclear disaster. Though, the methods and techniques for food radioactivity measurement already existing, the need of portable instrument is warranted to measure the radioactivity in food items in raw form. Measurement of radioactivity may help in quick and mass screening of food items in case of nuclear emergencies. Any enhanced level of radioactivity in food items especially in case of nuclear emergency need to be evaluated for controlling its spread and restriction of consumption by the public. This way, it may help in managing internal radioactivity contamination to human being

  15. Modeling for Airborne Contamination

    International Nuclear Information System (INIS)

    F.R. Faillace; Y. Yuan

    2000-01-01

    The objective of Modeling for Airborne Contamination (referred to from now on as ''this report'') is to provide a documented methodology, along with supporting information, for estimating the release, transport, and assessment of dose to workers from airborne radioactive contaminants within the Monitored Geologic Repository (MGR) subsurface during the pre-closure period. Specifically, this report provides engineers and scientists with methodologies for estimating how concentrations of contaminants might be distributed in the air and on the drift surfaces if released from waste packages inside the repository. This report also provides dose conversion factors for inhalation, air submersion, and ground exposure pathways used to derive doses to potentially exposed subsurface workers. The scope of this report is limited to radiological contaminants (particulate, volatile and gaseous) resulting from waste package leaks (if any) and surface contamination and their transport processes. Neutron activation of air, dust in the air and the rock walls of the drift during the preclosure time is not considered within the scope of this report. Any neutrons causing such activation are not themselves considered to be ''contaminants'' released from the waste package. This report: (1) Documents mathematical models and model parameters for evaluating airborne contaminant transport within the MGR subsurface; and (2) Provides tables of dose conversion factors for inhalation, air submersion, and ground exposure pathways for important radionuclides. The dose conversion factors for air submersion and ground exposure pathways are further limited to drift diameters of 7.62 m and 5.5 m, corresponding to the main and emplacement drifts, respectively. If the final repository design significantly deviates from these drift dimensions, the results in this report may require revision. The dose conversion factors are further derived by using concrete of sufficient thickness to simulate the drift

  16. Image Analysis in the Field of Oil Contamination Monitoring

    OpenAIRE

    Ceco, Ema

    2011-01-01

    Monitoring wear particles in lubricating oils allows specialists to evaluate thehealth and functionality of a mechanical system. The main analysis techniquesavailable today are manual particle analysis and automatic optical analysis. Man-ual particle analysis is effective and reliable since the analyst continuously seeswhat is being counted . The drawback is that the technique is quite time demand-ing and dependent of the skills of the analyst. Automatic optical particle countingconstitutes o...

  17. Implementation guide of internal contamination control

    International Nuclear Information System (INIS)

    Balter, Henia; Savio, Eduardo; Souto, Beatriz

    1994-01-01

    A review of current methods of contamination control for radioisotopes 131I, 125I and 99mTc, periodic control of personnel exposed to radiation.Maximum permissible body burden (Mpbb) for each radionuclide,radiotoxicity as danger of internal contamination directly related with Let, type of radiation,Ali values for various radionuclides and external irradiation as an opposed factor.Effective half life,examples, 99mTc in urine,iodine in thyroid caption, 99m Tc absorption by skin and mouth. Procedure of control and calculation by measurement of urine samples in a gamma spectrometer. Iodine thyroid caption by monitoring of thyroid with a solid NaI(TI)scintillator taking as background radiation the activity of upper leg muscle. Standard solutions are prepared to fill a thyroid phantoms.Results must not be higher than Mpbb of corresponding radionuclide.Bibliography

  18. Bioremediation of diesel oil-contaminated soil by composting with biowaste

    International Nuclear Information System (INIS)

    Gestel, Kristin van; Mergaert, Joris; Swings, Jean; Coosemans, Jozef; Ryckeboer, Jaak

    2003-01-01

    Composting of biowaste and diesel contaminated-soil is an efficient bioremediation method, with mature compost as a usable end product. - Soil spiked with diesel oil was mixed with biowaste (vegetable, fruit and garden waste) at a 1:10 ratio (fresh weight) and composted in a monitored composting bin system for 12 weeks. Pure biowaste was composted in parallel. In order to discern the temperature effect from the additional biowaste effect on diesel degradation, one recipient with contaminated soil was hold at room temperature, while another was kept at the actual composting temperature. Measurements of composting parameters together with enumerations and identifications of microorganisms demonstrate that the addition of the contaminated soil had a minor impact on the composting process. The first-order rate constant of diesel degradation in the biowaste mixture was four times higher than in the soil at room temperature, and 1.2 times higher than in the soil at composting temperature

  19. Trust versus confidence: Microprocessors and personnel monitoring

    International Nuclear Information System (INIS)

    Chiaro, P.J. Jr.

    1993-01-01

    Due to recent technological advances, substantial improvements have been made in personnel contamination monitoring. In all likelihood, these advances will close out the days of manually frisking personnel for radioactive contamination. Unfortunately, as microprocessor-based monitors become more widely used, not only at commercial power reactors but also at government facilities, questions concerning their trustworthiness arise. Algorithms make decisions that were previously made by technicians. Trust is placed not in technicians but in machines. In doing this it is assumed that the machine never misses. Inevitably, this trust drops, due largely to open-quotes false alarms.close quotes This is especially true when monitoring for alpha contamination. What is a open-quotes false alarm?close quotes Do these machines and their algorithms that we put our trust in make mistakes? An analysis was performed on half-body and hand-and-foot monitors at Oak Ridge National Laboratory (ORNL) in order to justify the suggested confidence level used for alarm point determination. Sources used in this analysis had activities approximating ORNL's contamination limits

  20. Application of GIS technologies to monitor secondary radioactive contamination in the Delegen mountain massif

    Science.gov (United States)

    Alipbeki, O.; Kabzhanova, G.; Kurmanova, G.; Alipbekova, Ch.

    2016-06-01

    The territory of the Degelen mountain massif is located within territory of the former Semipalatinsk nuclear test site and it is an area of ecological disaster. Currently there is a process of secondary radioactive contamination that is caused by geodynamic processes activated at the Degelen array, violation of underground hydrological cycles and as a consequence, water seepage into the tunnels. One of the methods of monitoring of geodynamic processes is the modern technology of geographic information systems (GIS), methods of satellite radar interferometry and high accuracy satellite navigation system in conjunction with radioecological methods. This paper discusses on the creation of a GIS-project for the Degelen array, facilitated by quality geospatial analysis of the situation and simulation of the phenomena, in order to maximize an objective assessment of the radiation situation in this protected area.

  1. Quantifying the effect of sorption and bioavailability of hydrophobic organic contaminants

    International Nuclear Information System (INIS)

    Zhang, W.; Bouwer, E.; Cunningham, A.

    1994-01-01

    In-situ bioremediation has been applied successfully at a few sites. Several restrictions presently exist which could greatly limit the effectiveness of this promising technology. Hydrophobic organic contaminants tend to sorb onto soil. However, microorganisms are most effective in utilizing substrates from the aqueous phase. Sorption tends to separate the direct contact between microorganisms and contaminants necessary for biodegradation to occur. A series of experiments, which represented scenarios with fast sorption/desorption, slow sorption/desorption, mass transfer across boundary layer and mass transfer within attached microorganisms (biofilm), was conducted to demonstrate the concentration effect and the mass transfer effect. A method has been developed to quantify bioavailability of organic contaminants in aquatic environments. Bioavailability Factor (B f ), a dimensionless parameter derived from mathematical models and verified by experimental results, has been formulated to describe the impact of equilibrium sorption, nonequilibrium sorption, and mass transfer processes on the rate and extent of biodegradation of petroleum hydrocarbons

  2. Evaluation of the homogeneity of reference flat sources used in calibration of surface contamination monitors

    International Nuclear Information System (INIS)

    Silva Junior, I.A.; Xavier, M.; Siqueira, P.T.D.; Potiens, M.P.A.

    2014-01-01

    The aim of this study was to re-evaluate the uniformity of the wide area reference sources of the Calibration Laboratory of Instruments (LCI-IPEN) used in the calibration of surface contamination monitors, according the recommendations of the ISO 8769 standard and the NRPB. In this work used six wide area reference sources of 150 cm 2 of 241 Am, 14 C, 36 Cl, 137 Cs, 90 Sr+ 90 Y and 99 Tc with reference dates between 1996 and 1997 and three sources of 100 cm 2 of 14 C, 137 Cs and 60 Co were used with reference dates 2007. Measurements were performed with a radiation monitor of the Thermo, model FH40GX with a pancake probe, model FHZ732GM. We also made several models on paper with the objective of define each measurement position and an aluminum plate with a square hole (6.25 cm 2 ) in its center, allowing the passage of the radiation only through the hole. Each wide area reference source was positioned in setup and measurements were performed in order to cover the entire surface of the source. The values of the uniformity obtained partially confirm previous data obtained in another study conducted by LCI-IPEN, showing that some wide area reference sources 150 cm 2 in disagree with ISO 8769. In the former work, just the source of 241 Am (7.3%) was within the range specified by the standard, now have sources of 241 Am (5.7%), 137 Cs (8.8%), 90 Sr+ 9 '0Y (8, 8%) and 99 Tc (9.2%) with values within the specified uniformity. The sources of 14 C (53.3%) and 36 Cl (16.6%) were outside the specified. The wide area reference sources of 100 cm 2 , show disagreement in values of uniformity of the sources 14 C (46.7%) and 60 Co (10.4%). The values of the uniformity of the wide area reference sources show that some fonts can not be used in calibrations, because not in accordance with the value of uniformity specified in ISO 8769:2010, this is a conditions to believe a laboratory according to ISO 17025, show the laboratory performs its services with a high quality. The

  3. Adverse effects of salivary contamination for adhesives in restorative dentistry. A literature review.

    Science.gov (United States)

    Nair, Pooja; Hickel, Reinhard; Ilie, Nicoleta

    2017-06-01

    To review and critically analyze the literature concerning the influence of salivary contamination on the bond quality of adhesives used in restorative materials by comparing and contrasting the different adhesive materials. A detailed search on PUBMED, Cochrane Library, Google Scholar and Web of Science was carried out to identify publications on salivary contamination and dental adhesive materials, from 1990-2017 (March) which resulted in a total of 6,202 web-identified publications. After screening titles/abstracts and de-duplicating, 54 publications were selected that matched the requirements for this review. The condition for selection was English literature concerning the effect of salivary contamination on the adhesives used in restorative dentistry. The obtained articles were systematically evaluated. Salivary contamination of adhesives during restorative procedures statistically (64.6%) showed an adverse effect on adhesives, occurring either at one or many stages of restoration. Methodological dissimilarities impeded the direct comparison of the selected studies. Nevertheless, the 2-step etch and rinse adhesives were relatively less vulnerable to salivary contamination than the others. 65% of the evaluated studies for decontamination achieved improved bonding when the contaminated surface was subjected to some kind of decontamination procedure. However, the duration and other specificities were not standard in all the evaluations and need further research to assess the course of action. It is necessary to do long term studies to evaluate the effectiveness of contaminated adhesive over time. Salivary contamination is a potential cause for poor bond quality of adhesive systems during restorative procedures and to provide a successful treatment, proper care must be taken to ensure the operating area is free from contamination. Understanding the properties of the materials and its constituents as well as considering measures to manage the potential

  4. Development of portable and automatic smear sampler for measuring surface contamination

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated.

  5. Development of portable and automatic smear sampler for measuring surface contamination

    International Nuclear Information System (INIS)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W.

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated

  6. System to control contamination during retrieval of buried TRU waste

    Science.gov (United States)

    Menkhaus, Daniel E.; Loomis, Guy G.; Mullen, Carlan K.; Scott, Donald W.; Feldman, Edgar M.; Meyer, Leroy C.

    1993-01-01

    A system to control contamination during the retrieval of hazardous waste comprising an outer containment building, an inner containment building, within the outer containment building, an electrostatic radioactive particle recovery unit connected to and in communication with the inner and outer containment buildings, and a contaminate suppression system including a moisture control subsystem, and a rapid monitoring system having the ability to monitor conditions in the inner and outer containment buildings.

  7. Abstracts of the 7. international conference on contaminants in freezing ground

    International Nuclear Information System (INIS)

    2010-01-01

    This conference presented recent scientific innovations and technologies designed to aid in the responsible management, remediation, and prevention of soil and groundwater contamination in regions with permafrost and seasonal frost. The effects of contaminants and pollutants on marine and terrestrial ecosystems were reviewed. Emerging issues related to Arctic ownership and the impacts of climate change were also discussed. Sessions included bioremediation; plants in cold climates; interception barriers and landfills; the Arctic development and sustainability; risk and toxicity in cold climates; contaminants from mining and oil and gas operations in cold climates; remediation and monitoring; and theoretical aspects. A technical poster session was also included. The conference featured 55 presentations, of which 10 have been catalogued separately for inclusion in this database. tabs., figs.

  8. Device for contamination monitoring against radiation contamination of people

    International Nuclear Information System (INIS)

    Rische, U.W.; Gerlach, R.

    1986-01-01

    The monitor has detector devices at an angle to each other made as a rigid component which can be rotated around a vertical axis in the angle between the joined detector devices. A reset drive which can be tensioned is provided at the axis of rotation. If it is in its rest position, a platform is situated as floor plate with a foot detector between the vertical detector devices. (orig./HP) [de

  9. Initial site characterization and evaluation of radionuclide contaminated soil waste burial grounds

    International Nuclear Information System (INIS)

    Phillips, S.J.; Reisenauer, A.E.; Rickard, W.H.; Sandness, G.A.

    1977-02-01

    A survey of historical records and literature containing information on the contents of 300 Area and North Burial Grounds was completed. Existing records of radioactive waste location, type, and quantity within each burial ground facility were obtained and distributed to cooperating investigators. A study was then initiated to evaluate geophysical exploration techniques for mapping buried waste materials, waste containers, and trench boundaries. Results indicate that a combination of ground penetrating radar, magnetometer, metal detector, and acoustic measurements will be effective but will require further study, hardware development, and field testing. Drilling techniques for recovering radionuclide-contaminated materials and sediment cores were developed and tested. Laboratory sediment characterization and fluid transport and monitoring analyses were begun by installation of in situ transducers at the 300 North Burial Ground site. Biological transport mechanisms that control radionuclide movement at contaminated sites were also studied. Flora and fauna presently inhabiting specific burial ground areas were identified and analyzed. Future monitoring of specific mammal populations will permit determination of dose rate and pathways of contaminated materials contained in and adjacent to burial ground sites

  10. Radiological Monitoring Equipment For Real-Time Quantification Of Area Contamination In Soils And Facility Decommissioning

    International Nuclear Information System (INIS)

    M. V. Carpenter; Jay A. Roach; John R Giles; Lyle G. Roybal

    2005-01-01

    The environmental restoration industry offers several systems that perform scan-type characterization of radiologically contaminated areas. The Idaho National Laboratory (INL) has developed and deployed a suite of field systems that rapidly scan, characterize, and analyze radiological contamination in surface soils. The base system consists of a detector, such as sodium iodide (NaI) spectrometers, a global positioning system (GPS), and an integrated user-friendly computer interface. This mobile concept was initially developed to provide precertification analyses of soils contaminated with uranium, thorium, and radium at the Fernald Closure Project, near Cincinnati, Ohio. INL has expanded the functionality of this basic system to create a suite of integrated field-deployable analytical systems. Using its engineering and radiation measurement expertise, aided by computer hardware and software support, INL has streamlined the data acquisition and analysis process to provide real-time information presented on wireless screens and in the form of coverage maps immediately available to field technicians. In addition, custom software offers a user-friendly interface with user-selectable alarm levels and automated data quality monitoring functions that validate the data. This system is deployed from various platforms, depending on the nature of the survey. The deployment platforms include a small all-terrain vehicle used to survey large, relatively flat areas, a hand-pushed unit for areas where maneuverability is important, an excavator-mounted system used to scan pits and trenches where personnel access is restricted, and backpack- mounted systems to survey rocky shoreline features and other physical settings that preclude vehicle-based deployment. Variants of the base system include sealed proportional counters for measuring actinides (i.e., plutonium-238 and americium-241) in building demolitions, soil areas, roadbeds, and process line routes at the Miamisburg Closure

  11. Biological monitoring and abatement program plan for Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Kszos, L.A.; Anderson, G.E.; Gregory, S.M.; Peterson, M.J.; Ryon, M.G.; Schilling, E.M.; Smith, J.G.; Southworth, G.R.; Phipps, T.L.

    1997-06-01

    The overall purpose of this plan is to evaluate the receiving streams' biological communities for the duration of the permit and meet the objectives for the ORNL BMAP as outlined in the NPDES permit (Appendix). The ORNL BMAP will focus on those streams in the WOC watershed that (1) receive NPDES discharges and (2) have been identified as ecologically impacted. In response to the newly issued NPDES permit, the tasks that are included in this BMAP plan include monitoring biological communities (fish and benthic invertebrates), monitoring mercury contamination in fish and water, monitoring polychlorinated biphenyl (PCB) contamination in fish, and evaluating temperature loading from ORNL outfalls. The ORNL BMAP will evaluate the effects of sediment and oil and grease, as well as the chlorine control strategy through the use of biological community data. Monitoring will be conducted at sites in WOC, First Creek, Fifth Creek, Melton Branch, and WOL

  12. Biological monitoring and abatement program plan for Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Kszos, L.A.; Anderson, G.E.; Gregory, S.M.; Peterson, M.J.; Ryon, M.G.; Schilling, E.M.; Smith, J.G.; Southworth, G.R. [Oak Ridge National Lab., TN (United States); Phipps, T.L. [CKY, Inc., Oak Ridge, TN (United States)

    1997-06-01

    The overall purpose of this plan is to evaluate the receiving streams` biological communities for the duration of the permit and meet the objectives for the ORNL BMAP as outlined in the NPDES permit (Appendix). The ORNL BMAP will focus on those streams in the WOC watershed that (1) receive NPDES discharges and (2) have been identified as ecologically impacted. In response to the newly issued NPDES permit, the tasks that are included in this BMAP plan include monitoring biological communities (fish and benthic invertebrates), monitoring mercury contamination in fish and water, monitoring polychlorinated biphenyl (PCB) contamination in fish, and evaluating temperature loading from ORNL outfalls. The ORNL BMAP will evaluate the effects of sediment and oil and grease, as well as the chlorine control strategy through the use of biological community data. Monitoring will be conducted at sites in WOC, First Creek, Fifth Creek, Melton Branch, and WOL.

  13. In Situ Analytical Characterization of Contaminated Sites Using Nuclear Spectrometry Techniques. Review of Methodologies and Measurements

    International Nuclear Information System (INIS)

    2017-01-01

    Past and current human activities can result in the contamination of sites by radionuclides and heavy metals. The sources of contamination are various. The most important sources for radionuclide release include global fallout from nuclear testing, nuclear and radiological accidents, waste production from nuclear facilities, and activities involving naturally occurring radioactive material (NORM). Contamination of the environment by heavy metals mainly originates from industrial applications and mineralogical background concentration. Contamination of sites by radionuclides and heavy metals can present a risk to people and the environment. Therefore, the estimation of the contamination level and the identification of the source constitute important information for the national authorities with the responsibility to protect people and the environment from adverse health effects. In situ analytical techniques based on nuclear spectrometry are important tools for the characterization of contaminated sites. Much progress has been made in the design and implementation of portable systems for efficient and effective monitoring of radioactivity and heavy metals in the environment directly on-site. Accordingly, the IAEA organized a Technical Meeting to review the current status and trends of various applications of in situ nuclear spectrometry techniques for analytical characterization of contaminated sites and to support Member States in their national environmental monitoring programmes applying portable instrumentation. This publication represents a comprehensive review of the in situ gamma ray spectrometry and field portable X ray fluorescence analysis techniques for the characterization of contaminated sites. It includes papers on the use of these techniques, which provide useful background information for conducting similar studies, in the following Member States: Argentina, Australia, Brazil, Czech Republic, Egypt, France, Greece, Hungary, Italy, Lithuania

  14. Effects of initial nitrogen addition on deep-soils bioventing at a fuel-contaminated site

    International Nuclear Information System (INIS)

    Ratz, J.W.; Guest, P.R.; Downey, D.C.

    1994-01-01

    A ruptured pipe at a Burlington Northern Railroad (BNRR) fueling pump house resulted in over 60,000 gallons of No. 2 diesel fuel spilling onto the surrounding soil. An initial investigation of site conditions indicated that subsurface soils were contaminated with diesel fuel to ground water, which was observed approximately 70 feet below the ground surface. State regulatory agencies requested that BNRR develop and implement a remedial action plan to treat these diesel-contaminated soils and protect local ground waters. Engineering-Science, Inc. (ES) was retained for this work and, after evaluating a variety of remediation technologies recommended using soil venting methods to enhance the immediate volatilization and long-term biodegradation of fuel residuals. ES designed and implemented a ''bioventing'' pilot test to determine soil properties such as air permeability, and to assess the potential for partial volatilization and long-term biodegradation of diesel fuel residuals at the site. Hydrocarbon concentrations, carbon dioxide, and oxygen levels were monitored at a vapor extraction well (VEW) and six vapor monitoring points (VMPs) to determine the rates of volatilization and biological degradation of fuel residuals. Pilot test results confirmed that full-scale bioventing was feasible for the remediation of this site

  15. Behavioral response to contamination risk information in a spatially explicit groundwater environment: Experimental evidence

    Science.gov (United States)

    Li, Jingyuan; Michael, Holly A.; Duke, Joshua M.; Messer, Kent D.; Suter, Jordan F.

    2014-08-01

    This paper assesses the effectiveness of aquifer monitoring information in achieving more sustainable use of a groundwater resource in the absence of management policy. Groundwater user behavior in the face of an irreversible contamination threat is studied by applying methods of experimental economics to scenarios that combine a physics-based, spatially explicit, numerical groundwater model with different representations of information about an aquifer and its risk of contamination. The results suggest that the threat of catastrophic contamination affects pumping decisions: pumping is significantly reduced in experiments where contamination is possible compared to those where pumping cost is the only factor discouraging groundwater use. The level of information about the state of the aquifer also affects extraction behavior. Pumping rates differ when information that synthesizes data on aquifer conditions (a "risk gauge") is provided, despite invariant underlying economic incentives, and this result does not depend on whether the risk information is location-specific or from a whole aquifer perspective. Interestingly, users increase pumping when the risk gauge signals good aquifer status compared to a no-gauge treatment. When the gauge suggests impending contamination, however, pumping declines significantly, resulting in a lower probability of contamination. The study suggests that providing relatively simple aquifer condition guidance derived from monitoring data can lead to more sustainable use of groundwater resources.

  16. Combined Contamination and Space Environmental Effects on Solar Cells and Thermal Control Surfaces

    Science.gov (United States)

    Dever, Joyce A.; Bruckner, Eric J.; Scheiman, David A.; Stidham, Curtis R.

    1994-01-01

    For spacecraft in low Earth orbit (LEO), contamination can occur from thruster fuel, sputter contamination products and from products of silicone degradation. This paper describes laboratory testing in which solar cell materials and thermal control surfaces were exposed to simulated spacecraft environmental effects including contamination, atomic oxygen, ultraviolet radiation and thermal cycling. The objective of these experiments was to determine how the interaction of the natural LEO environmental effects with contaminated spacecraft surfaces impacts the performance of these materials. Optical properties of samples were measured and solar cell performance data was obtained. In general, exposure to contamination by thruster fuel resulted in degradation of solar absorptance for fused silica and various thermal control surfaces and degradation of solar cell performance. Fused silica samples which were subsequently exposed to an atomic oxygen/vacuum ultraviolet radiation environment showed reversal of this degradation. These results imply that solar cells and thermal control surfaces which are susceptible to thruster fuel contamination and which also receive atomic oxygen exposure may not undergo significant performance degradation. Materials which were exposed to only vacuum ultraviolet radiation subsequent to contamination showed slight additional degradation in solar absorptance.

  17. [Monitoring of contamination of foodstuffs with elements noxious to human health. Part I. Wheat cereal products, vegetable products, confectionery and products for infants and children (2004 year)].

    Science.gov (United States)

    Wojciechowska-Mazurek, Maria; Starska, Krystyna; Brulińska-Ostrowska, Elzbieta; Plewa, Monika; Biernat, Urszula; Karłowski, Kazimierz

    2008-01-01

    The testing of products of wheat cereal (310 samples), vegetable (418 samples), confectionery (439 samples) and 952 samples of products for infants and children has initiated the 5-years cycle of monitoring investigations on food contamination with elements noxious to human health planned to perform in 2004-2008. The parties involved in testing were: laboratories of State Sanitary Inspection collecting samples on all over the territory of Poland, both from retail market (of domestic origin as well as imported) and directly from producers; the national reference laboratory of the Department of Food and Consumer Articles Research of National Institute of Public Health - National Institute of Hygiene responsible for elaboration of official food control and monitoring plans to be approved by Chief Sanitary Inspectorate and for the substantive supervising of tests performance. The reported metals contents were not of health concern and generally below the levels set forth in food legislation. The health hazard assessment was performed taking into account the mean contamination obtained and average domestic consumption of these food products groups in Poland. The highest intake expressed as the percentage of provisional tolerable weekly intake (PTWI) was obtained for cadmium, which has reached 9.4% PTWI for cereal based products and 4.7% PTWI for vegetables. The cadmium content in chocolate and derived products due to contamination of cocoa beans and the levels of this element in products for infants and children originated from contamination of cereal and soybeans row materials should not be ignored. The decrease of lead contamination comparing to those reported in 1990 studies was observed.

  18. PCDD/F and WHO-PCB contamination in an industrialized area in Brazil. First results of atmospheric monitoring and the use of Tillandsia usneoides (L) as biomonitor

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, M. de S. [Dept. de Geoquimica, Univ. Federal Fluminense. Niteroi, RJ (Brazil); Waller, U.; Reifenhaeuser, W.; Koerner, W. [Bavarian Environmental Protection Agency, Augsburg (Germany); Torres, J.P.; Malm, O. [Inst. de Biofisica, CCS-UFRJ. Ilha do Fundao, RJ (Brazil)

    2004-09-15

    A major issue of concern in developing countries like Brazil is to conciliate increasing industrialization rates to secure health and environmental standards already required to promote the free market among countries. This was pointed out during the United Nations Conference on Environment and Development in Rio de Janeiro in 1992 (Agenda 21). There it became clear that Brazil needs to develop better methods and techniques for environmental monitoring in order to control pollution sources and promote sustainable development. Among dozens of different kinds of persistent organic pollutants, polychlorinated dibenzodioxins and dibenzofurans (PCDD/PCDF) and polychlorinated biphenyls (PCB) are a matter of great concern due to their persistence, bioaccumulation and toxicological properties. PCDD and PCDF are unwanted by-products from the combustion of organic material containing trace amounts of chlorine set free in both stationary thermal sources and diffuse fuel burning. They can also be present as unwanted by-products of various industrial and metallurgical processes and metal recycling and smelters. PCB are ubiquitous contaminants of the environment and can be produced during thermal processes. In spite of their high environmental persistence and relevance in human health concerns, legal aspects regarding maximum emission limits and control of these contaminants are absent in Brazil at present. Moreover, the absence of adequately equipped laboratories and human resources together with the high costs associated hampers the research and monitoring of these contaminants in Brazil. The present work is a first report of the monitoring of total deposition rates of PCDD/PCDF and PCB in Volta Redonda City, a highly industrialized area in Rio de Janeiro State. Simultaneously, the use of an endemic Bromeliad species, Tillandsia usneoides (L), an epiphytic bromeliad, as a possible bio-monitor for persistent organochlorine compounds was investigated.

  19. Subsurface biogenic gas rations associated with hydrocarbon contamination

    International Nuclear Information System (INIS)

    Marrin, D.L.

    1991-01-01

    Monitoring the in situ bioreclamation of organic chemicals in soil is usually accomplished by collecting samples from selected points during the remediation process. This technique requires the installation and sampling of soil borings and does not allow for continuous monitoring. The analysis of soil vapor overlying hydrocarbon-contaminated soil and groundwater has been used to detect the presence of nonaqueous phase liquids (NAPL) and to locate low-volatility hydrocarbons that are not directly detected by more conventional soil gas methods. Such soil vapor sampling methods are adaptable to monitoring the in situ bioremediation of soil and groundwater contamination. This paper focuses on the use of biogenic gas ratio in detecting the presence of crude oil and gasoline in the subsurface

  20. The effect of organic contaminants on the spectral induced polarization response of porous media - mechanistic approach

    Science.gov (United States)

    Schwartz, N.; Huisman, J. A.; Furman, A.

    2012-12-01

    In recent years, there is a growing interest in using geophysical methods in general and spectral induced polarization (SIP) in particular as a tool to detect and monitor organic contaminants within the subsurface. The general idea of the SIP method is to inject alternating current through a soil volume and to measure the resultant potential in order to obtain the relevant soil electrical properties (e.g. complex impedance, complex conductivity/resistivity). Currently, a complete mechanistic understanding of the effect of organic contaminants on the SIP response of soil is still absent. In this work, we combine laboratory experiments with modeling to reveal the main processes affecting the SIP signature of soil contaminated with organic pollutant. In a first set of experiments, we investigate the effect of non-aqueous phase liquids (NAPL) on the complex conductivity of unsaturated porous media. Our results show that addition of NAPL to the porous media increases the real component of the soil electrical conductivity and decreases the polarization of the soil (imaginary component of the complex conductivity). Furthermore, addition of NAPL to the soil resulted in an increase of the electrical conductivity of the soil solution. Based on these results, we suggest that adsorption of NAPL to the soil surface, and exchange process between polar organic compounds in the NAPL and inorganic ions in the soil are the main processes affecting the SIP signature of the contaminated soil. To further support our hypothesis, the temporal change of the SIP signature of a soil as function of a single organic cation concentration was measured. In addition to the measurements of the soil electrical properties, we also measured the effect of the organic cation on the chemical composition of both the bulk and the surface of the soil. The results of those experiments again showed that the electrical conductivity of the soil increased with increasing contaminant concentration. In addition

  1. Interactive effects of Cd and PAHs on contaminants removal from co-contaminated soil planted with hyperaccumulator plant Sedum alfredii

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Kai; Huang, Huagang; Li, Tingqiang; Yang, Xiaoe [Zhejiang Univ., Hangzhou (China). MOE Key Lab. of Environment Remediation and Ecosystem Health; Zhu, Zhiqiang [Zhejiang Univ., Hangzhou (China). MOE Key Lab. of Environment Remediation and Ecosystem Health; Hainan Univ., Haikou (China). College of Agriculture; He, Zhenli [Florida Univ., Port Pierce, FL (United States). Inst. of Food and Agricultural Sciences; Alva, Ashok [US Department of Agriculture, Prosser, WA (United States). Agricultural Research Service

    2012-04-15

    Purpose: Soil contamination by multiple organic and inorganic contaminants is common but its remediation by hyperaccumulator plants is rarely reported. The growth of a cadmium (Cd) hyperaccumulator Sedum alfredii and removal of contaminants from Cd and polycyclic aromatic hydrocarbons (PAHs) co-contaminated soil were reported in this study. Materials and methods: Soil slightly contaminated by Cd (0.92 mg kg{sup -1} DW) was collected from a vegetable field in Hangzhou and was spiked with two levels (0 and 6 mg kg{sup -1} DW) of Cd and three levels (0, 25, and 150 mg kg{sup -1} DW) of phenanthrene (PHE) or pyrene (PYR). A pot experiment was conducted in a greenhouse using S. alfredii with unplanted controls for 60 days. Shoot and root biomass of plants, dehydrogenase activity (DHA), and microbial biomass carbon in the soil were measured. Concentrations of Cd and PAHs in the plant and soil were determined. Results and discussion: Elevated Cd level (6.38 mg kg{sup -1} DW) increased S. alfredii growth. The presence of PAHs decreased the stimulatory effects of Cd on plant biomass and Cd concentrations in shoots in Cd spiked soil, thus decreasing Cd phytoextraction efficiency. Cadmium removal by S. alfredii after 60 days of growth varied from 5.8% to 6.7% and from 5.7% to 9.6%, in Cd unspiked and spiked soils, respectively. Removal rate of PAHs in the soil was similar with or without the plants. Removal rate of PYR decreased at the elevated Cd level in the soil. This appears to be due to a decrease in soil microbial activity. This is confirmed by a decrease in DHA, which is a good indicator of soil microbial activity. Conclusions: Our results demonstrate that S. alfredii could effectively extract Cd from Cd-contaminated soils in the presence of PHE or PYR; however, both PAHs exhibited negative effects on phytoextraction of Cd from Cd spiked soil (6.38 mg kg{sup -1} DW). S. alfredii is not suitable for remediation of PAHs. The effects of Cd and PAHs concentrations on the

  2. Natural attenuation of diesel aliphatic hydrocarbons in contaminated agricultural soil

    International Nuclear Information System (INIS)

    Serrano, Antonio; Gallego, Mercedes; Gonzalez, Jose Luis; Tejada, Manuel

    2008-01-01

    A diesel fuel spill at a concentration of 1 L m -2 soil was simulated on a 12 m 2 plot of agricultural land, and natural attenuation of aliphatic hydrocarbons was monitored over a period of 400 days following the spill after which the aliphatic hydrocarbon concentrations were found to be below the legal contamination threshold for soil. The main fraction of these compounds (95%) remained at the surface layer (0-10 cm). Shortly after the spill (viz. between days 0 and 18), evaporation was the main origin of the dramatic decrease in pollutant concentrations in the soil. Thereafter, soil microorganisms used aliphatic hydrocarbons as sources of carbon and energy, as confirmed by the degradation ratios found. Soil quality indicators, soil microbial biomass and dehydrogenase activity, regained their original levels about 200 days after the spill. - The effect of aliphatic hydrocarbons contamination on soil quality was monitored over a period of 400 days after a Diesel fuel spill

  3. Monitoring psychrotrophic lactic acid bacteria contamination in a ready-to-eat vegetable salad production environment.

    Science.gov (United States)

    Pothakos, Vasileios; Snauwaert, Cindy; De Vos, Paul; Huys, Geert; Devlieghere, Frank

    2014-08-18

    A study monitoring lactic acid bacteria contamination was conducted in a company producing fresh, minimally processed, packaged and ready-to-eat (RTE) vegetable salads (stored at 4°C) in order to investigate the reason for high psychrotrophic LAB levels in the products at the end of shelf-life. Initially, high microbial counts exceeding the established psychrotrophic thresholds (>10(7)-10(8)CFU/g) and spoilage manifestations before the end of the shelf-life (7days) occurred in products containing an assortment of sliced and diced vegetables, but within a one year period these spoilage defects became prevalent in the entire processing plant. Environmental sampling and microbiological analyses of the raw materials and final products throughout the manufacturing process highlighted the presence of high numbers of Leuconostoc spp. in halved and unseeded, fresh sweet bell peppers provided by the supplier. A combination of two DNA fingerprinting techniques facilitated the assessment of the species diversity of LAB present in the processing environment along with the critical point of their introduction in the production facility. Probably through air mediation and surface adhesion, mainly members of the strictly psychrotrophic species Leuconostoc gelidum subsp. gasicomitatum and L. gelidum subsp. gelidum were responsible for the cross-contamination of every vegetable handled within the plant. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels

    International Nuclear Information System (INIS)

    Miller Julianne J.; Mizell Steve A.; Nikolich George; Campbell Scott A.

    2012-01-01

    The U.S. Department of Energy (DOE) National Nuclear Security Administration (NNSA), Nevada Site Office (NSO), Environmental Restoration Soils Activity has authorized the Desert Research Institute (DRI) to conduct field assessments of potential sediment transport of contaminated soil from Corrective Action Unit (CAU) 550, Area 8 Smoky Contamination Area (CA), during precipitation runoff events. CAU 550 includes Corrective Action Sites (CASs) 08-23-03, 08-23-04, 08-23-06, and 08-23-07; these CASs are associated with tests designated Ceres, Smoky, Oberon, and Titania, respectively.

  5. Time-Lapse Electrical Geophysical Monitoring of Amendment-Based Biostimulation.

    Science.gov (United States)

    Johnson, Timothy C; Versteeg, Roelof J; Day-Lewis, Frederick D; Major, William; Lane, John W

    2015-01-01

    Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling-based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation. Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation. In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surface-based ERT in conjunction with limited field sampling to improve spatial

  6. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    Science.gov (United States)

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  7. Soil monitoring as a part of environment monitoring in Slovakia

    International Nuclear Information System (INIS)

    Kobza, J.

    1997-01-01

    In frame of Soil monitoring system it is going about a lot of methods in advance as follows: methods of soil monitoring sites selection and soil monitoring network construction, as well; methods of soil survey and soil sampling; analytical methods (indicating of chemical, agrochemical and physical properties); soil database and methods of evaluation and interpretation of measured results. The monitoring network was constructed on the base of ecological principles - including the monitoring of all soil types and subtypes, various climatic and emission regions as well as relatively clean regions, lowland and highland. Soil monitoring network in forest land is regular (8 x 8 km) with regard to International monitoring system in Forestry. The soil monitoring network in Slovakia consist of 650 monitoring sites (312 sites in farming land and 338 sites in forest land). In addition soil monitoring network includes also 21 monitoring sites. All monitoring sites are geodesically located and reported on the map at a scale of 1:5000. There are the methods concerning the important soil parameters indication with regard to main soil degradation processes a s follows: soil contamination (heavy metals and organic contaminants); soil acidification; soil salinity; soil erosion (deluometrically by the Cs-137 and remote sensing methods); soil compaction; soil fertility and protection. Analytical control system was elaborated according to Good Laboratory Practice. Evaluation of soil monitoring network results is not simple because it depends on various monitored parameters, on aim of evaluation as well as on the scale of landscape which is object for evaluation. There are used the modern statistical methods in monitoring system which can be: universal; disjunctive; simulated. Used statistical methods are significant for interpretation of measured results as follows: trends in landscape; anisotropy; comparison. The evaluation and interpretation way is very significant with regard not

  8. Air contamination analysis during emergency medical treatment

    International Nuclear Information System (INIS)

    Yamada, Y.; Fukutsu, K.; Yuuki, M.; Akashi, M.

    2009-01-01

    After radiological emergencies, patients contaminated with radioactivity are taken to radiation emergency hospitals for treatment. Numerical simulations using the computer software 'Flow Designer R were made in order to evaluate indoor air contamination caused by the breathing out of contaminated air. The National Inst. of Radiological Sciences facility was used for the numerical evaluation. Results indicate that the dispersion of contaminated air depends on the characteristics of the contaminants, and that the dispersion range was limited and localised. Only medical staff standing in a special position near the patient was exposed to almost un-diluted contaminated air. Highly contaminated air was evacuated with a local exhaust pump system. Room air quality was monitored using a continuous air sampling system, but it was found that the sampling point was not representative for the purpose of radiation protection. From the air-flow analysis, some problems that affect radiological safety were revealed and valuable information and measures for preventing secondary contamination were determined. (authors)

  9. Effect of type of defeathering system on Salmonella cross-contamination during commercial processing.

    Science.gov (United States)

    Clouser, C S; Knabel, S J; Mast, M G; Doores, S

    1995-04-01

    The cross-contamination effects of three commercial defeathering systems were compared using turkeys from a single Salmonella-positive flock (defeathered in each system as the first flock of the day and compared with 30 hand-defeathered (control) birds. Three trials, each using a different common flock, were completed. In Trial 1, the incidence of Salmonella-positive birds decreased following mechanical defeathering at all three processors. The incidence of Salmonella-positive carcasses in test flocks increased following steam-spray (approximately 100%) and kosher (approximately 50%) defeathering in Trials 2 and 3, whereas no increase in Salmonella-positive carcasses resulted from conventional defeathering. The decrease in the number of Salmonella-positive birds as a result of defeathering observed in Trial 1, as compared to increases observed in Trials 2 and 3, may be related to the selection of feather-contaminated (Trial 1) vs intestinal-colonized (Trials 2 and 3) turkeys. Surface temperature of the carcasses and length of time required to defeather were monitored within each system. It is hypothesized that the increases in the number of Salmonella-positive birds following steam-spray and kosher defeathering in Trials 2 and 3 were a result of skin surface changes occurring during the defeathering process, which allowed increased adherence or entrapment of Salmonella spp. on or within remaining skin layers.

  10. Proposal of traceability chain for direct measurements of radioactive contamination in Cuba

    International Nuclear Information System (INIS)

    Walwyn Salas, Gonzalo; Tamayo Garcia, Jose A.; Cornejo Diaz, Nestor

    2008-01-01

    The measurements of the radioactive surface contamination are common used to demonstrate the compliance with safety regulations at national level. It is mandatory that those measurements are traceable to national standards through the suitable calibration of the monitors used for survey. In Cuba, there is not a harmonized methodology for evaluation of contamination from direct measurements and no standardized calibration service for portable monitors is routinely provided to users. The Secondary Standard Dosimetry Laboratory of Cuba has recently established the calibration service of contamination monitors in terms of instrument efficiency using the reference sources of known emission rate per unit area in accordance with international normative ISO 8769. In the present paper, is proposed a traceable scheme of direct measurements of contamination that involve the calibration at the laboratory level using multi-source method and the evaluation of contaminations at user level in terms of activity per unit area. Some improvements from the previous single-source method of calibration are explained in order to support the advantages that offer the new chain for those measurements in the country. (author)

  11. Trace Contaminant Monitor for Air in Spacecraft, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A need exists for analyzers that can measure trace contaminants in air on board spacecraft. Toxic gas buildup can endanger the crew particularly during long...

  12. Microbe and Mineral Mediated Transformation of Heavy Metals, Radionuclides, and Organic Contaminants

    Science.gov (United States)

    Gerlach, R.

    2011-12-01

    Microorganisms influence their surroundings in many ways and humans have utilized microbially catalyzed reactions for benefit for centuries. Over the past few decades, microorganisms have been used for the control of contaminant transport in subsurface environments where many microbe mineral interactions occur. This presentation will discuss microbially influenced mineral formation and transformation as well as their influence on the fate of organic contaminants such as chlorinated aliphatics & 2,4,6-trinitrotoluene (TNT), heavy metals such as chromium, and radionuclides such as uranium & strontium. Both, batch and flow experiments have been performed, which monitor the net effect of microbe mineral interactions on the fate of these contaminants. This invited presentation will place an emphasis on the relative importance of direct microbial (i.e. biotic) transformations, mineral-mediated transformations as well as other abiotic reactions influencing the fate of environmental contaminants. Experiments will be summarized and placed in context of past and future engineered applications for the control of subsurface contaminants.

  13. The Effect of Canal Contamination with Saliva on Apical Sealing

    Directory of Open Access Journals (Sweden)

    S Sabaghi

    2014-08-01

    Full Text Available Introduction: Root canal obturation aims at sealing the root canal system to prevent re-contamination of canal and periapical space. Presence of moisture in canal before obturation may posit a negative effect on the quality of canal sealing. Therefore, this study was conducted to investigate the effect of canal contamination with saliva on apical microleakage. Methods: In this laboratory study, 58 human uni-root teeth were cleaned and shaped for obturation with gutta percha and sealer AH26. In the case group, specimens were contaminated with human saliva immediately before obturation, whereas the teeth in the control group were kept dry. All canals were filled by lateral condensation technique. Moreover, the teeth were placed in methylene blue dye for 3 days. Dye penetration was measured using a stereomicrosope. As a matter of fact, the study data were analyzed via utilizing t-test. Results: A significant difference was found between the two groups in regard with the apical leakage(P<0.001. The microleakage mean of dye in the dry group was 3/48mm, whereas it was 6/36mm in the saliva contaminated group. Conclusion: The study findings revealed that complete drying of canal can improve apical sealing.

  14. Groundwater contamination and its effect on health in Turkey.

    Science.gov (United States)

    Baba, Alper; Tayfur, Gokmen

    2011-12-01

    The sources of groundwater pollution in Turkey are identified, and pathways of contaminants to groundwater are first described. Then, the effects of groundwater quality on health in Turkey are evaluated. In general, sources of groundwater contamination fall into two main categories: natural and anthropogenic sources. Important sources of natural groundwater pollution in Turkey include geological formations, seawater intrusion, and geothermal fluid(s). The major sources of anthropogenic groundwater contamination are agricultural activities, mining waste, industrial waste, on-site septic tank systems, and pollution from imperfect well constructions. The analysis results revealed that natural contamination due to salt and gypsum are mostly found in Central and Mediterranean regions and arsenic in Aegean region. Geothermal fluids which contain fluoride poses a danger for skeleton, dental, and bone problems, especially in the areas of Denizli, Isparta, and Aydın. Discharges from surface water bodies contaminate groundwater by infiltration. Evidence of such contamination is found in Upper Kızılırmak basin, Gediz basin, and Büyük Melen river basin and some drinking water reservoirs in İstanbul. Additionally, seawater intrusion causes groundwater quality problems in coastal regions, especially in the Aegean coast. Industrial wastes are also polluting surface and groundwater in industrialized regions of Turkey. Deterioration of water quality as a result of fertilizers and pesticides is another major problem especially in the regions of Mediterranean, Aegean, Central Anatolia, and Marmara. Abandoned mercury mines in the western regions of Turkey, especially in Çanakkale, İzmir, Muğla, Kütahya, and Balıkesir, cause serious groundwater quality problems.

  15. Refurbishing tritium contaminated ion sources

    International Nuclear Information System (INIS)

    Wright, K.E.; Carnevale, R.H.; McCormack, B.E.; Stevenson, T.; Halle, A. von

    1995-01-01

    Extended tritium experimentation on TFTR has necessitated refurbishing Neutral Beam Long Pulse Ion Sources (LPIS) which developed operational difficulties, both in the TFTR Test Cell and later, in the NB Source Refurbishment Shop. Shipping contaminated sources off-site for repair was not permissible from a transport and safety perspective. Therefore, the NB source repair facility was upgraded by relocating fixtures, tooling, test apparatus, and three-axis coordinate measuring equipment; purchasing and fabricating fume hoods; installing exhaust vents; and providing a controlled negative pressure environment in the source degreaser/decon area. Appropriate air flow monitors, pressure indicators, tritium detectors and safety alarms were also included. The effectiveness of various decontamination methods was explored while the activation was monitored. Procedures and methods were developed to permit complete disassembly and rebuild of an ion source while continuously exhausting the internal volume to the TFTR Stack to avoid concentrations of tritium from outgassing and minimize personnel exposure. This paper presents upgrades made to the LPIS repair facility, various repair tasks performed, and discusses the effectiveness of the decontamination processes utilized

  16. Copper Contamination Impairs Herbivore Initiation of Seaweed Inducible Defenses and Decreases Their Effectiveness.

    Directory of Open Access Journals (Sweden)

    Alexandria M Warneke

    Full Text Available Seaweed-herbivore interactions are often mediated by environmental conditions, yet the roles of emerging anthropogenic stressors on these interactions are poorly understood. For example, chemical contaminants have unknown consequences on seaweed inducible resistance and herbivore response to these defenses despite known deleterious effects of contaminants on animal inducible defenses. Here, we investigated the effect of copper contamination on the interactions between a snail herbivore and a brown seaweed that displays inducible resistance to grazing. We examined seaweed inducible resistance and its effectiveness for organisms exposed to copper at two time points, either during induction or after herbivores had already induced seaweed defenses. Under ambient conditions, non-grazed tissues were more palatable than grazed tissues. However, copper additions negated the preference for non-grazed tissues regardless of the timing of copper exposure, suggesting that copper decreased both how herbivores initiated these inducible defenses and their subsequent effectiveness. Copper decreased stimulation of defenses, at least in part, by suppressing snail grazing pressure-the cue that turns inducible defenses on. Copper decreased effectiveness of defenses by preventing snails from preferentially consuming non-grazed seaweed. Thus, contaminants can potentially stress communities by changing seaweed-herbivore interactions mediated via inducible defenses. Given the ubiquity of seaweed inducible resistance and their potential influence on herbivores, we hypothesize that copper contamination may change the impact of these resistant traits on herbivores.

  17. Cost-effectiveness of monitoring free flaps.

    Science.gov (United States)

    Subramaniam, Shiva; Sharp, David; Jardim, Christopher; Batstone, Martin D

    2016-06-01

    Methods of free flap monitoring have become more sophisticated and expensive. This study aims to determine the cost of free flap monitoring and examine its cost effectiveness. We examined a group of patients who had had free flaps to the head and neck over a two-year period, and combined these results with costs obtained from business managers and staff. There were 132 free flaps with a success rate of 99%. The cost of monitoring was Aus $193/flap. Clinical monitoring during this time period cost Aus$25 476 and did not lead to the salvage of any free flaps. Cost equivalence is reached between monitoring and not monitoring only at a failure rate of 15.8%. This is to our knowledge the first study to calculate the cost of clinical monitoring of free flaps, and to examine its cost-effectiveness. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. All rights reserved.

  18. Sources of electron contamination for the Clinac-35 25-MV photon beam

    International Nuclear Information System (INIS)

    Petti, P.L.; Goodman, M.S.; Sisterson, J.M.; Biggs, P.J.; Gabriel, T.A.; Mohan, R.

    1983-01-01

    A detailed Monte Carlo approach has been employed to investigate the sources of electron contamination for the 25-MV photon beam generated by Varian's Clinac-35. Three sources of contamination were examined: (a) the flattening filter and beam monitor chamber, (b) the fixed primary collimators downstream from the monitor chamber and the adjustable photon jaws, and (c) the air volume separating the treatment head from the observation point. Five source-to-surface distances (SSDs) were considered for a single field size, 28 cm in diameter at 80 cm SSD. It was found that for small SSDs (80-100 cm), the dominant sources of electron contamination were the flattening filter and the beam monitor chamber which accounted for 70% of the unwanted electrons. Thirteen percent of the remaining electrons originated in the downstream primary collimators and the photon jaws, and 17% were produced in air. At larger SSDs, the fraction of unwanted electrons originating in air increased. At 400 cm SSD, 61% of the contaminating electrons present in the beam were produced in air, 34% originated in the flattening filter and beam monitor chamber, and 5% were due to interactions in the fixed collimators downstream from the monitor chamber and the adjustable photon jaws. These calculated results are substantiated by recent experiments

  19. The influence of Triga 2000 reactor operation on the surface contamination at reactor room using smear test method

    International Nuclear Information System (INIS)

    Bintu Khoiriyyah; Budi Purnama; Tri Cahyo Laksono

    2016-01-01

    The monitoring of surface contamination should be conducted to determine the safety of work areas. Surface contamination at the TRIGA 2000 reactor room which is on PSTNT-BATAN Bandung remain to be implemented although reactor not operating. In this research monitoring of surface contamination when TRIGA 2000 in operation of the first time after several years not operating aims to determine the influence on the results of monitoring. The monitoring of surface contamination has been done using smear test method at some predetermined in TRIGA 2000 reactor room. The highest surface contamination activities is obtained 0.32 Bq/cm 2 and there are some points that are not detected. Based on keputusan kepala BAPETEN No.1/Ka BAPETEN/ V/99 the work showed that the TRIGA 2000 reactor in the category of low area contamination, that is <3.7 Bq/cm 2 to gross beta. (author)

  20. Geophysical Signitures From Hydrocarbon Contaminated Aquifers

    Science.gov (United States)

    Abbas, M.; Jardani, A.

    2015-12-01

    The task of delineating the contamination plumes as well as studying their impact on the soil and groundwater biogeochemical properties is needed to support the remediation efforts and plans. Geophysical methods including electrical resistivity tomography (ERT), induced polarization (IP), ground penetrating radar (GPR), and self-potential (SP) have been previously used to characterize contaminant plumes and investigate their impact on soil and groundwater properties (Atekwana et al., 2002, 2004; Benson et al., 1997; Campbell et al., 1996; Cassidy et al., 2001; Revil et al., 2003; Werkema et al., 2000). Our objective was to: estimate the hydrocarbon contamination extent in a contaminated site in northern France, and to adverse the effects of the oil spill on the groundwater properties. We aim to find a good combination of non-intrusive and low cost methods which we can use to follow the bio-remediation process, which is planned to proceed next year. We used four geophysical methods including electrical resistivity tomography, IP, GPR, and SP. The geophysical data was compared to geochemical ones obtained from 30 boreholes installed in the site during the geophysical surveys. Our results have shown: low electrical resistivity values; high chargeability values; negative SP anomalies; and attenuated GPR reflections coincident with groundwater contamination. Laboratory and field geochemical measurements have demonstrated increased groundwater electrical conductivity and increased microbial activity associated with hydrocarbon contamination of groundwater. Our study results support the conductive model suggested by studies such as Sauck (2000) and Atekwana et al., (2004), who suggest that biological alterations of hydrocarbon contamination can substantially modify the chemical and physical properties of the subsurface, producing a dramatic shift in the geo-electrical signature from resistive to conductive. The next stage of the research will include time lapse borehole

  1. Aging effects on oil-contaminated Kuwaiti sand

    International Nuclear Information System (INIS)

    Al-Sanad, H.A.; Ismael, N.F.

    1997-01-01

    Large quantities of oil-contaminated sands resulted from the destruction of oil wells and the formation of oil lakes in Kuwait at the end of the Gulf Wa/r. A laboratory testing program was carried out to determine the geotechnical properties of this material and the effect of aging on their properties. Tests included direct shear, triaxial, and consolidation tests on clean and contaminated sand at the same relative density. The influence of aging was examined by testing uncontaminated sand after aging for one, three, and six months in natural environmental conditions. The results indicated increased strength and stiffness due to aging and a reduction of the oil content due to evaporation of volatile compounds. The factors that influence the depth of oil penetration in compacted sand columns were also examined including the type of oil, relative density, and the amount of fines

  2. Finite element modeling of contaminant transport in soils including the effect of chemical reactions.

    Science.gov (United States)

    Javadi, A A; Al-Najjar, M M

    2007-05-17

    The movement of chemicals through soils to the groundwater is a major cause of degradation of water resources. In many cases, serious human and stock health implications are associated with this form of pollution. Recent studies have shown that the current models and methods are not able to adequately describe the leaching of nutrients through soils, often underestimating the risk of groundwater contamination by surface-applied chemicals, and overestimating the concentration of resident solutes. Furthermore, the effect of chemical reactions on the fate and transport of contaminants is not included in many of the existing numerical models for contaminant transport. In this paper a numerical model is presented for simulation of the flow of water and air and contaminant transport through unsaturated soils with the main focus being on the effects of chemical reactions. The governing equations of miscible contaminant transport including advection, dispersion-diffusion and adsorption effects together with the effect of chemical reactions are presented. The mathematical framework and the numerical implementation of the model are described in detail. The model is validated by application to a number of test cases from the literature and is then applied to the simulation of a physical model test involving transport of contaminants in a block of soil with particular reference to the effects of chemical reactions. Comparison of the results of the numerical model with the experimental results shows that the model is capable of predicting the effects of chemical reactions with very high accuracy. The importance of consideration of the effects of chemical reactions is highlighted.

  3. False indications of {sup 95}Zr-{sup 95}Nb internal contamination due to contaminated sacred thread

    Energy Technology Data Exchange (ETDEWEB)

    Garg, S P; Singh, I S; Sharma, R C [Internal Dosimetry Division, Bhabha Atomic Research Centre, BARC Hospital, Mumbai (India)

    2000-05-01

    Whole body monitoring of a worker showed an apparent internal contamination with a considerable amount of {sup 95}Zr-{sup 95}Nb. Inhalation exposure was suspected to have taken place about a week earlier when he had last worked in the radioactive area. Unexpected fast clearance indicated by the third periodical weekly follow up monitoring was considered to be an abnormal behaviour. Investigations revealed an external contamination on a sacred thread, which the worker was putting on across his thorax and not removing it at the time of bath due to religious considerations. These studies have underscored that short term follow up measurements data should be critically scrutinized and a caution should be exercised in the interpretation such data particularly in case of such relatively short lived radionuclides. (author)

  4. Case studies in organic contaminant hydrogeology

    International Nuclear Information System (INIS)

    Baker, J.A.

    1989-01-01

    The effective management of domestic solid waste and hazardous, toxic, and radioactive waste is a major problem in the area of environmental geology and water sciences throughout the world. A series of case studies is presented of organic contaminants from both solid and hazardous waste disposal facilities to provide examples of these problems. The facilities were investigated to determine risks and liabilities before acquisition, to determine the site hydrogeologic conditions for design of appropriate groundwater monitoring plans, and/or to determine the potential for groundwater contamination. The case studies are of disposal facilities located in glacial tills, carbonaceous weathered clay soils, weathered shale, limestone bedrock, dolomite bedrock, and alluvial and sedimentary deposits. The results of these studies and investigations show certain relationships in the distribution of organic pollutants to the different geologic and hydrogeologic characteristics of each facility. In each of the four case studies, all 129 priority pollutants were analyzed in private wells and/or monitoring wells. The 31 volatile organic compounds (VOCs) of the priority pollutant list were the majority of organic compounds detected. When VOCs are found in groundwater impacted by disposal facilities, they are present in groups and tend to be distributed in patterns based on their relative concentrations. It is rare to find only one or two VOCs from facilities where leakage has been detected. The ethylenes and ethanes appear to be more prevalent and mobile than aromatic VOCs. The aromatics are restricted primarily to leachates and wastes and in monitoring wells located adjacent to facilities. 2 refs., 15 figs

  5. Reconditioning contaminated gravel

    International Nuclear Information System (INIS)

    Walsh, H.; Bowers, J.S.; Cadwell, K.

    1995-02-01

    Lawrence Livermore National Laboratory (LLNL) has developed a portable screening system that will recondition radioactively contaminated gravel in the field. The separation technique employed by this system removes dirt, contaminated debris, and other fine particles from gravel. At LLNL, gravel is used in conjunction with the experimental testing of explosives to reduce shock wave propagation. The gravel surrounds the experimental device and buffers the energy generated from the explosion. During an explosion, some of the gravel is broken down into small particles and mixed with contaminants. Contaminants in the used gravel originate from metal sheathing and other parts comprising, the experimental device. These contaminants may consist of radionuclides and metals that are considered hazardous by the State of California when disposed. This paper describes the process that conveys contaminated material into the screener system, sprays the material with recycled water or other mild cleaning chemicals, and separates particles based on size. Particles greater than a specified size are discharged out of the screener separator and recycled back into use, thereby reducing the amount of mixed waste generated and minimizing the need for new gravel. The fines or silt are flushed out of the separator with the water and are removed from the water and consolidated into a drum with the use of a hydrocyclone separator and drum decant system. Because the water in the spray system is recycled, minimal makeup water is needed. The system monitors pH and total dissolved solids

  6. Two methodologies for optical analysis of contaminated engine lubricants

    International Nuclear Information System (INIS)

    Aghayan, Hamid; Yang, Jun; Bordatchev, Evgueni

    2012-01-01

    The performance, efficiency and lifetime of modern combustion engines significantly depend on the quality of the engine lubricants. However, contaminants, such as gasoline, moisture, coolant and wear particles, reduce the life of engine mechanical components and lubricant quality. Therefore, direct and indirect measurements of engine lubricant properties, such as physical-mechanical, electro-magnetic, chemical and optical properties, are intensively utilized in engine condition monitoring systems and sensors developed within the last decade. Such sensors for the measurement of engine lubricant properties can be used to detect a functional limit of the in-use lubricant, increase drain interval and reduce the environmental impact. This paper proposes two new methodologies for the quantitative and qualitative analysis of the presence of contaminants in the engine lubricants. The methodologies are based on optical analysis of the distortion effect when an object image is obtained through a thin random optical medium (e.g. engine lubricant). The novelty of the proposed methodologies is in the introduction of an object with a known periodic shape behind a thin film of the contaminated lubricant. In this case, an acquired image represents a combined lubricant–object optical appearance, where an a priori known periodic structure of the object is distorted by a contaminated lubricant. In the object shape-based optical analysis, several parameters of an acquired optical image, such as the gray scale intensity of lubricant and object, shape width at object and lubricant levels, object relative intensity and width non-uniformity coefficient are newly proposed. Variations in the contaminant concentration and use of different contaminants lead to the changes of these parameters measured on-line. In the statistical optical analysis methodology, statistical auto- and cross-characteristics (e.g. auto- and cross-correlation functions, auto- and cross-spectrums, transfer function

  7. Effects of two different blends of naturally mycotoxin-contaminated maize meal on growth and metabolic profile in replacement heifers.

    Science.gov (United States)

    Abeni, F; Migliorati, L; Terzano, G M; Capelletti, M; Gallo, A; Masoero, F; Pirlo, G

    2014-10-01

    The aim of this trial was to assess the effects of the administration of different combinations of mycotoxins in naturally contaminated maize grains on dairy heifer growth, blood measurements and puberty onset. A total of 35 Friesian female heifers were randomly allotted to three experimental groups from 18-21 to 42-45 weeks of age. During the 24-week experimental period (EP), heifers were fed the same diet, but with maize meal derived from three differently contaminated lots: very low contamination, as control (C); medium-low aflatoxin-contaminated (A); and mixed aflatoxin-fumonisin contaminated (A-F). At the end of the EP, they returned to a common diet without contaminated maize, and they were monitored for an additional period of 12 weeks (post-experimental period, PEP). BW, wither height, hip height, body length and heart girth were measured every 4 weeks from the beginning of EP to the end of PEP. At the same time, body condition score was evaluated and blood samples were taken from the jugular vein to be analysed for haematological, serum protein and metabolic profiles. Age at puberty was assessed by measuring weekly plasma progesterone levels from 40 to 52 weeks of age. Body growth measurements were processed both by ANOVA of average daily gain of EP and PEP separately, and by the analysis of growth curve parameters. Haematological, serum protein and metabolic profile were evaluated using a mixed model, taking into account the repeated measurements in time on each animal. Heifers' growth was delayed both in A and A-F groups during EP, as evidenced by the different linear coefficients of the BW growth curve in the three groups. Differently contaminated diets did not affect the haematological profile, so that it can be concluded that these levels of mycotoxin contamination do not determine any specific effect on haematopoiesis and immunity in growing heifers. The main blood marker of mycotoxin chronic toxicity was the γ-glutamyl transferase activity level in

  8. MURMoT. Design and Application of Microbial Uranium Reduction Monitoring Tools

    Energy Technology Data Exchange (ETDEWEB)

    Loeffler, Frank E. [Univ. of Tennessee, Knoxville, TN (United States)

    2014-12-31

    Uranium (U) contamination in the subsurface is a major remediation challenge at many DOE sites. Traditional site remedies present enormous costs to DOE; hence, enhanced bioremediation technologies (i.e., biostimulation and bioaugmentation) combined with monitoring efforts are being considered as cost-effective corrective actions to address subsurface contamination. This research effort improved understanding of the microbial U reduction process and developed new tools for monitoring microbial activities. Application of these tools will promote science-based site management decisions that achieve contaminant detoxification, plume control, and long-term stewardship in the most efficient manner. The overarching hypothesis was that the design, validation and application of a suite of new molecular and biogeochemical tools advance process understanding, and improve environmental monitoring regimes to assess and predict in situ U immobilization. Accomplishments: This project (i) advanced nucleic acid-based approaches to elucidate the presence, abundance, dynamics, spatial distribution, and activity of metal- and radionuclide-detoxifying bacteria; (ii) developed proteomics workflows for detection of metal reduction biomarker proteins in laboratory cultures and contaminated site groundwater; (iii) developed and demonstrated the utility of U isotopic fractionation using high precision mass spectrometry to quantify U(VI) reduction for a range of reduction mechanisms and environmental conditions; and (iv) validated the new tools using field samples from U-contaminated IFRC sites, and demonstrated their prognostic and diagnostic capabilities in guiding decision making for environmental remediation and long-term site stewardship.

  9. Effective dielectric mixture model for characterization of diesel contaminated soil

    International Nuclear Information System (INIS)

    Al-Mattarneh, H.M.A.

    2007-01-01

    Human exposure to contaminated soil by diesel isomers can have serious health consequences like neurological diseases or cancer. The potential of dielectric measuring techniques for electromagnetic characterization of contaminated soils was investigated in this paper. The purpose of the research was to develop an empirical dielectric mixture model for soil hydrocarbon contamination application. The paper described the basic theory and elaborated in dielectric mixture theory. The analytical and empirical models were explained in simple algebraic formulas. The experimental study was then described with reference to materials, properties and experimental results. The results of the analytical models were also mathematically explained. The proposed semi-empirical model was also presented. According to the result of the electromagnetic properties of dry soil contaminated with diesel, the diesel presence had no significant effect on the electromagnetic properties of dry soil. It was concluded that diesel had no contribution to the soil electrical conductivity, which confirmed the nonconductive character of diesel. The results of diesel-contaminated soil at saturation condition indicated that both dielectric constant and loss factors of soil were decreased with increasing diesel content. 15 refs., 2 tabs., 9 figs

  10. Advanced dust monitoring system applied to new TRU handling facility of JAERI

    International Nuclear Information System (INIS)

    Yabuta, H.; Shigeta, Y.; Sawahata, K.; Hasegawa, K.

    1993-01-01

    In JAERI, a large, scale multipurpose facility is under construction, which consists of a TRU waste management testing installation, a solution fuel treatment installation and critical assemblies with uranium and/or plutonium solution fuel. The facility is also equipped with a lot of gloveboxes for handling and treatment of solution fuel and hot cells for research on reprocessing process. As there may be a relatively high potential of air contamination, it is important to monitor air contamination effectively and efficiently. An advanced dust monitoring system was introduced for convenience of handling and automatical measurement of filter papers, by developing a filter-holder with an IC memory and a radioactivity measuring device with an automatic filter-holder changing mechanism as a part of a centralized monitoring system with a computer

  11. Bioremediation of oil contaminated soils

    International Nuclear Information System (INIS)

    Beeson, D.L.; Hogue, J.I.; Peterson, J.C.; Guerra, G.W.

    1994-01-01

    The Baldwin Waste Oil Site was an abandoned waste oil recycling facility located in Robstown, Nueces County, Texas. As part of their site assessment activities, the US Environmental Protection Agency (EPA) requested that the Ecology and Environment, Inc., Technical Assistance Team (TAT) investigate the feasibility of using in-situ bioremediation to remediate soils contaminated with oil and grease components, petroleum hydrocarbons, and volatile organic compounds. Bioremediation based on the land treatment concept was tested. The land treatment concept uses techniques to optimize indigenous microbial populations and bring them in contact with the contaminants. The study was designed to collect data upon which to base conclusions on the effectiveness of bioremediation, to demonstrate the effectiveness of bioremediation under field conditions, and to identify potential problems in implementing a full-scale project. Bioremediation effectiveness was monitored through total petroleum hydrocarbons (TPH) and Oil and Grease (O and G) analyses. Site specific treatment goals for the pilot project were concentrations of less than 1% for O and G and less than 10,000 mg/kg for TPH. Based on the reduction of TPH and O and G concentrations and the cost effectiveness of bioremediation based on the land treatment concept, full-scale in-situ bioremediation was initiated by the EPA at the Baldwin Waste Oil Site in February of 1993

  12. Post monitoring of a cyclodextrin remeditated chlorinated solvent contaminated aquifer

    Science.gov (United States)

    Blanford, W. J.

    2006-12-01

    Hydroxypropyl-â-cyclodextrin (HPâCD) has been tested successfully in the laboratory and in the field for enhanced flushing of low-polarity contaminants from aquifers. The cyclodextrin molecule forms a toroidal structure, which has a hydrophobic cavity. Within this cavity, organic compounds of appropriate shape and size can form inclusion complexes, which is the basis for the use of cyclodextrin in groundwater remediation. The hydrophilic exterior of the molecule makes cyclodextrin highly water-soluble. The solubility of cyclodextrins can be further enhanced by adding functional groups, such as hydroxypropyl groups, to the cyclodextrin core. The aqueous solubility of HPâCD exceeds 950 g/L. These high solubilities are advantageous for field applications because they permit relatively high concentrations of the flushing agent. In order for cyclodextrin to become a feasible remediative alternative, it must be demonstrate a short term resistance to biodegradation during field application, but ultimately biodegrade so as not to pose a long term presence in the aquifer. The potential for degradation of cyclodextrin as well as changes in the chlorinated solvents and groundwater geochemistry were examined during the post monitoring of a field demonstration in a shallow aquifer at Little Creek Naval Amphibious Base in Virginia. It was found that a portion of the cyclodextrin remaining in the aquifer after the cessation of field activities biodegraded during the 425 days of post monitoring. This degradation also led to the degradation of the chlorinated solvents trichloroethylene and 1,1-trichloroethane through both biological and chemical processes. The aquifer remained anaerobic with average dissolved oxygen levels below 0.5 mg/L. Dissolved nitrate and sulfate concentrations within the cyclodextrin plume decreased due their being used as terminal electron acceptors during the degradation of the cyclodextrin. The concentrations of total iron at the field site showed no

  13. Effect of photoactivation on the reduction of composite resin contamination.

    Science.gov (United States)

    Pauletti, Natalia A; Girotto, Luiza P S; Leite, Françoise H S; Mario, Débora N

    2017-06-01

    Composite resins are predominantly marketed in developing countries in tube form, and the contents of the tube may be used in numerous procedures for different patients. This represents a problem because of the risk of cross-contamination. This study aimed to evaluate contamination in vitro of the internal contents of composite resin tubes in the dental clinics of a higher-education institution, as well as the effect of photoactivation on the level of contamination. Twenty-five tubes containing composite resin were randomly chosen (by lottery). From each tube, two samples of approximately 2 mm of composite resin were removed, and then one sample, but not the other, was photoactivated. These samples were plated on Brain-Heart Infusion (BHI), Sabouraud and MacConkey agars, and the plates were incubated at 37°C for 24-48 h. Colony counting and Gram staining were performed for subsequent microscopic identification of fungi and bacteria. The non-photoactivated composite resin group presented significantly higher microbial contamination in relation to the photoactivated composite resin group. The photoactivation of camphorquinone present in composite resin produces reactive oxygen species, which might promote cell death of contaminant microorganisms. Thus, although the same tube of composite resin may be used for a number of different patients in the dental clinics of developing countries, the photoactivation process potentially reduces the risk of cross-contamination. © 2017 Eur J Oral Sci.

  14. Effectiveness of alcohol gelin stethoscopes disinfection contaminated with methicillinresistant Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    Arthur Alves Teixeira

    2015-10-01

    Full Text Available Background and Objectives: Although widely used, little attention has been given to basic-care in handling and disinfection of stethoscopes. Methicillin-resistant Staphylococcus aureus is frequently found and a major risk for hospitalized patients. Alcohol gel contains properties admittedly effective to exterminate germs that are frequently involved in infections. This study aims to verify the effectiveness of alcohol gel in stethoscopes disinfection contaminated with MRSA used by healthcare professionals of a University Hospital in Rio de Janeiro State. Methods: Health care professionals were selected randomly from August to November 2012, and collected samples with sterile swab of 105 stethoscopes before and after cleaning with alcohol gel 70% and performed cultures and bacterial identification. Results: Bacterial contamination was present in 87 (82.85% of the analyzed stethoscopes. Gram positive bacteria were identified in 76 (72.38%. S. aureus was present in 7.61% of stethoscopes and MRSA in 87.5% of them. After using the alcohol gel, there was a reduction of 71,44% of the general bacterial contamination and MRSA elimination of 100% of the analyzed stethoscopes. Conclusion: One should improve care in cleaning of stethoscopes due to the risk of carrying pathogenic bacteria involved in hospital infections. The alcohol gel showed to be adequate for disinfection of stethoscopes contaminated with MRSA. KEYWORDS: Stethoscopes. Contamination. Ethanol. Disinfection. Methicillinresistant Staphylococcus aureus.

  15. Fourth report on the Oak Ridge National Laboratory Biological Monitoring and Abatement Program for White Oak Creek Watershed and the Clinch River

    Energy Technology Data Exchange (ETDEWEB)

    Loar, J.M. [ed.

    1994-04-01

    In response to a condition of the National Pollutant Discharge Elimination System (NPDES) permit issued to Oak Ridge National Laboratory (ORNL) on April 1, 1986, a Biological Monitoring and Abatement Program (BMAP) was developed for White Oak Creek (WOC) and selected tributaries. BMAP currently consists of six major tasks that address both radiological and nonradiological contaminants in the aquatic and terrestrial environs on-site and the aquatic environs off-site. These tasks are (1) toxicity monitoring, (2) bioaccumulation monitoring of nonradiological contaminants in aquatic biota, (3) biological indicator studies, (4) instream ecological monitoring, (5) assessment of contaminants in the terrestrial environment, and (6) radioecology of WOC and White Oak Lake. The ecological characterization of the WOC watershed will provide baseline data that can be used to document the ecological effects of the water pollution control program and the remedial action program. The long-term nature of BMAP ensures that the effectiveness of remedial measures will be properly evaluated.

  16. Hydrodebridement of wounds: effectiveness in reducing wound bacterial contamination and potential for air bacterial contamination.

    Science.gov (United States)

    Bowling, Frank L; Stickings, Daryl S; Edwards-Jones, Valerie; Armstrong, David G; Boulton, Andrew Jm

    2009-05-08

    The purpose of this study was to assess the level of air contamination with bacteria after surgical hydrodebridement and to determine the effectiveness of hydro surgery on bacterial reduction of a simulated infected wound. Four porcine samples were scored then infected with a broth culture containing a variety of organisms and incubated at 37 degrees C for 24 hours. The infected samples were then debrided with the hydro surgery tool (Versajet, Smith and Nephew, Largo, Florida, USA). Samples were taken for microbiology, histology and scanning electron microscopy pre-infection, post infection and post debridement. Air bacterial contamination was evaluated before, during and after debridement by using active and passive methods; for active sampling the SAS-Super 90 air sampler was used, for passive sampling settle plates were located at set distances around the clinic room. There was no statistically significant reduction in bacterial contamination of the porcine samples post hydrodebridement. Analysis of the passive sampling showed a significant (p air whilst using hydro surgery equipment compared with a basal count of 582 CFUs/m3. During removal of the wound dressing, a significant increase was observed relative to basal counts (p air samples was still significantly raised 1 hour post-therapy. The results suggest a significant increase in bacterial air contamination both by active sampling and passive sampling. We believe that action might be taken to mitigate fallout in the settings in which this technique is used.

  17. Predicted effects of countermeasures on radiation doses from contaminated food

    International Nuclear Information System (INIS)

    Yamamoto, Hideaki; Nielsen, S.P.; Nielsen, F.

    1993-02-01

    Quantitative assessments of the effects on radiation-dose reductions from nine typical countermeasures against accidental fod contamination have been carried out with dynamic radioecological models. The foodstuffs are assumed to be contaminated with iodine-131, caesium-134 and caesium-137 after a release of radioactive materials from the Ringhals nuclear power station in Sweden resulting from a hypothetical core melt accident. The release of activity of these radionuclides is assumed at 0.07% of the core inventory of the unit 1 reactor (1600 TBq of I-131, 220 TBq of Cs-134 and 190 TBq of Cs-137). Radiation doses are estimated for the 55,000 affected inhabitants along the south-eastern coast of Sweden eating locally produced foodstuffs. The average effective dose equivalent to an individual in the critical group is predicted to be 2.9 mSv from food consumption contaminated with I-131. An accident occurring during winter is estimated to cause average individual doses of 0.32 mSv from Cs-134 and 0.47 mSv from Cs-137, and 9.4 mSv and 6.8 mSv from Cs-134 and Cs-137, respectively, for an accident occurring during summer. Doses from the intake of radioiodine may be reduced by up to a factor of 60 by rejecting contaminated food for 30 days. For the doses from radiocaesium, the largest effect is found form deep ploughing which may reduce the dose by up to a factor of 80. (au) (12 tabs., 6 ills., 19 refs.)

  18. Biochemical markers for the assessment of aquatic environment contamination

    Science.gov (United States)

    Havelková, Marcela; Randák, Tomáš; Blahová, Jana; Slatinská, Iveta; Svobodová, Zdeňka

    2008-01-01

    The need for assessment of aquatic ecosystem contamination and of its impact on water dwelling organisms was developed in response to rising aquatic environmental pollution. In this field study, liver enzymes of phase I and phase II of xenobiotic transformation, namely cytochrome P450, ethoxyresorufin-O-deethylase, glutathione-S-transferase and tripeptide glutathione were used to assess the contamination of the aquatic environment at different rivers in the Czech Republic. The indicator species selected was the male chub (Leuciscus cephalus L.) and male brown trout (Salmo trutta fario). Chemical analyses included also the assessment of the most important inductors of previously mentioned biochemical markers. The major inductors of monitored biomarkers are industrial contaminants which belong to a large group of organic pollutants (PCB, PAH, PCDD/F, DDT, HCH, HCB and OCS), persistent in the environment. Four different groups of river basins were assessed: the River Tichá Orlice and its tributary the Kralický brook; important tributaries of the River Elbe (the rivers Orlice, Chrudimka, Cidlina, Jizera, Vltava, Ohře and Bílina); major rivers in the Czech Republic (the rivers Lužnice, Otava, Sázava, Berounka, Vltava, Labe, Ohře, Svratka, Dyje, Morava and Odra) and the River Vltava. The use of the biochemical markers together with chemical analyses seems to be an effective way to monitor the quality of aquatic environment. PMID:21218108

  19. On predicting monitoring system effectiveness

    Science.gov (United States)

    Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo

    2015-03-01

    While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.

  20. Urban atmospheric contamination

    International Nuclear Information System (INIS)

    Baldasano Jose, M.

    1997-01-01

    The problems of contamination are not only limited to this century, pale pathology evidences of the effects of the contamination of the air exist in interiors in the health of the old ones; the article mention the elements that configure the problem of the atmospheric contamination, atmospheric pollutants and emission sources, orography condition and effects induced by the urbanization process