WorldWideScience

Sample records for constant illumination rats

  1. Effect constant and natural illumination on physiological state in rats

    Directory of Open Access Journals (Sweden)

    Ilyukha Viktor Alexandrovitch

    2012-03-01

    Full Text Available The influences of constant and natural illumination on antioxidant system, leukocytes differential count, speed of pubescence and life span of male laboratory rats was investigated. The changes of melatonin level secretion by constant and natural illumination leads to connected reorganization in physiological systems functioning and speed of ageing.

  2. Effects of Melatonin on Morphological and Functional Parameters of the Pineal Gland and Organs of Immune System in Rats During Natural Light Cycle and Constant Illumination.

    Science.gov (United States)

    Litvinenko, G I; Shurlygina, A V; Gritsyk, O B; Mel'nikova, E V; Tenditnik, M V; Avrorov, P A; Trufakin, V A

    2015-10-01

    We studied the response of the pineal gland and organs of the immune system to melatonin treatment in Wistar rats kept under conditions of abnormal illumination regimen. The animals were kept under natural light regimen or continuous illumination for 14 days and then received daily injections of melatonin (once a day in the evening) for 7 days. Administration of melatonin to rats kept at natural light cycle was followed by a decrease in percent ratio of CD4+8+ splenocytes and CD4-8+ thymocytes. In 24-h light with the following melatonin injections were accompanied by an increase in percent rate and absolute amount of CD4+8+ cells in the spleen, and a decrease in percent rate of CD11b/c and CD4-8+ splenocytes. In the thymus amount of CD4-8+ cells increased, and absolute number of CD4+25+ cells reduced. Melatonin significantly decreased lipofuscin concentration in the pineal gland during continuous light. Direction and intensity of effects of melatonin on parameters of cell immunity and state of the pineal gland were different under normal and continuous light conditions. It should be taken into account during using of this hormone for correction of immune and endocrine impairments developing during change in light/dark rhythm.

  3. Constant illumination reduces circulating melatonin and impairs immune function in the cricket Teleogryllus commodus

    Directory of Open Access Journals (Sweden)

    Joanna Durrant

    2015-07-01

    Full Text Available Exposure to constant light has a range of negative effects on behaviour and physiology, including reduced immune function in both vertebrates and invertebrates. It is proposed that the associated suppression of melatonin (a ubiquitous hormone and powerful antioxidant in response to the presence of light at night could be an underlying mechanistic link driving the changes to immune function. Here, we investigated the relationship between constant illumination, melatonin and immune function, using a model invertebrate species, the Australian black field cricket, Teleogryllus commodus. Crickets were reared under either a 12 h light: 12 h dark regimen or a constant 24 h light regimen. Circulating melatonin concentration and immune function (haemocyte concentration, lytic activity and phenoloxidase (PO activity were assessed in individual adult crickets through the analysis of haemolymph. Constant illumination reduced melatonin and had a negative impact on haemocyte concentrations and lytic activity, but its effect on PO activity was less apparent. Our data provide the first evidence, to our knowledge, of a link between exposure to constant illumination and variation in haemocyte concentration in an invertebrate model, while also highlighting the potential complexity of the immune response following exposure to constant illumination. This study provides insight into the possible negative effect of artificial night-time lighting on the physiology of invertebrates, but whether lower and potentially more ecologically relevant levels of light at night produce comparable results, as has been reported in several vertebrate taxa, remains to be tested.

  4. Preservation of rat skeletal muscle energy metabolism by illumination.

    Science.gov (United States)

    Lindgård, Ann; Lundberg, Jonas; Rakotonirainy, Olivier; Elander, Anna; Soussi, Bassam

    2003-04-25

    Skeletal muscle viability is crucially dependent on the tissue levels of its high energy phosphates. In this study we investigated the effect of the preservation medium Perfadex and illumination with Singlet Oxygen Energy (SOE). Singlet oxygen can be produced photochemically by energy transfer from an excited photosensitizer. The energy emitted from singlet oxygen upon relaxation to its triplet state is captured as photons at 634 nm and is here referred to as SOE. Rat hind limb rectus femoris muscles were preserved for five hours at 22 degrees C in Perfadex, saline, SOE illuminated Perfadex or SOE illuminated saline. Extracts of the muscles were analysed by 31P NMR. Data were analysed using two-way analysis of variance and are given as mean values micromol/g dry weight) +/- SEM. The ATP concentration was higher (p = 0.006) in saline groups (4.52) compared with Perfadex groups (2.82). There was no statistically significant difference in PCr between the saline groups (1.25) and Perfadex groups (0.82). However, there were higher (p = 0.003) ATP in the SOE illuminated groups (4.61) compared with the non-illuminated groups (2.73). The PCr was also higher (p < 0.0001) in the SOE illuminated groups (1.89) compared with the non-illuminated groups (0.18). In conclusion, Perfadex in this experimental model was incapable of preserving the high energy phosphates in skeletal muscle during 5 hours of ischemia. Illumination with SOE at 634 nm improved the preservation potential, in terms of a positive effect on the energy status of the muscle cell.

  5. APTZ Adjustment Based on LFPL Under Constant Illumination Condition%恒定光照下基于LFPL的APTZ调节

    Institute of Scientific and Technical Information of China (English)

    苏洁; 印桂生; 魏振华; 刘亚辉

    2011-01-01

    为提高光照恒定情况下视觉系统中PTZ调节的主动性和稳定性,提出恒定光照下基于LFPL的APTZ调节方法.采用基于局部粒子滤波的目标预定位方法,对运动目标实现自动估计的标定,提高系统调节的主动性,解决非线性跟踪问题.动态选取光照不变特征滤波粒子克服了光照变化和噪声等因素对目标预定位方法的影响,增强视觉系统的鲁棒性.对水平角和抑角采用Fuzzy控制方法,提高视觉跟踪系统的稳定性.实验结果表明,该方法是正确有效的,使用该系统对变速运动目标的长距离跟踪结果较传统方法更稳定,在光照变化和噪声条件下的运动目标跟踪实验也取得较好的结果.%To improve the initivative and stability of Pan-Tilt-Zoom(PTZ) adjustment in visual system under constant illumination condition,Active Pan-Tilt-Zoom(APTZ) adjustment method based on Local particle Filtering Pre-Location(LFPL) under constant illumination condition is proposed. Target pre-location mehtod based on local particle filter is used to realize automatic estimation calibratiing for moving target. Initivative of PTZ adjusting is improved and nonlinear tracking problem can be settled. Dynamic selecting illumination-inviarants as filtering particles can overcome the affect of illumination varying and noise in target pre-location algorithm and robust of visual system is improved. Fuzzy control method is used to control pan and tilt to improve the stability of visual tracking system. The correctness and accuracy are tested by experiments. Long distance tracking for varying speed moving target using this method shows it is more stabile than the traditional method. Moving target racking under varying illumination and noise conditions shows ideal result.

  6. Design of LED Driver with Constant Illumination Adjusting%恒照度调光的LED驱动器设计

    Institute of Scientific and Technical Information of China (English)

    刘珊; 宫杰; 鲍建宇

    2014-01-01

    With the development of lighting technology and the increasing requirements of energy,green lighting becomes the main re-search issues.Aiming at the problems of traditional lighting such as low efficency and huge electric power consumption,a kind of LED constant illumination adjusting driver is designed.It uses constant current LED control IC NCL30160 as the driving circuit of LED light sources,uses the illuminance sensor TSL2561 to collect indoor illuminance,and realizes the closed-loop control through the corresponding algorithm of the controller,so that indoor constant illumination adj usting is realized.The algorithm makes the PWM wave change smooth so as to avoid the flash of light cased by unexpected PWM changes.Meanwhile,the system increases the human motion control and uses different programs when people come in or not,so that the design becomes more power-frugal and intelligent.%随着照明技术的不断发展以及能源的日益紧张,绿色照明成为主要的研究方向。本文针对传统照明能效低、耗电量大等问题,设计了 LED恒照度调光驱动器。系统使用恒流 LED控制芯片 NCL30160作为 LED光源驱动电路,采用TSL2561光照度传感器采集室内光照度,通过处理器相应算法进行闭环控制,实现室内的恒照度调光。该算法实现了PWM波形平滑变化,避免因PWM突变造成闪光。同时,系统增加了人体运动控制,实现无人、有人时的不同调光方案,使设计进一步节能和智能化。

  7. Investigating the influence of chromatic aberration and optical illumination bandwidth on fundus imaging in rats

    Science.gov (United States)

    Li, Hao; Liu, Wenzhong; Zhang, Hao F.

    2015-10-01

    Rodent models are indispensable in studying various retinal diseases. Noninvasive, high-resolution retinal imaging of rodent models is highly desired for longitudinally investigating the pathogenesis and therapeutic strategies. However, due to severe aberrations, the retinal image quality in rodents can be much worse than that in humans. We numerically and experimentally investigated the influence of chromatic aberration and optical illumination bandwidth on retinal imaging. We confirmed that the rat retinal image quality decreased with increasing illumination bandwidth. We achieved the retinal image resolution of 10 μm using a 19 nm illumination bandwidth centered at 580 nm in a home-built fundus camera. Furthermore, we observed higher chromatic aberration in albino rat eyes than in pigmented rat eyes. This study provides a design guide for high-resolution fundus camera for rodents. Our method is also beneficial to dispersion compensation in multiwavelength retinal imaging applications.

  8. Effects of continuous environmental illumination on the albino rat hypothalamo-neurohypophysial system.

    Science.gov (United States)

    Weiss, M L; Smith, J E; Sokhansanj, A; Rusch, P; Landis, C; Hatton, G I

    1995-01-01

    Continuous environmental illumination or constant light (LL) exposure causes a suppression of daily water intake, and long-term exposure of greater than 19 days produces a hypertrophy of magnocellular neuroendocrine cells (MNCs) in the hypothalamus. These findings led Glantz to hypothesize that LL increases the secretion of vasopressin (VP). We wanted to determine whether LL could trigger morphological changes within the hypothalamo-neurohypophysial system (HNS) seen with other manipulations that result in enhanced hormone release. The posterior pituitary of male albino rats that were exposed to LL for 24 or 48 h were examined ultrastructurally for evidence of enhanced hormone release. In addition, water intake, plasma VP levels, and MNC size within the supraoptic nucleus (SON) were measured. After LL exposure, the posterior pituitary morphology was different, suggesting enhanced hormone release. LL exposure did not affect plasma VP or the size of SON MNCs, but did suppress drinking behavior. These data show that posterior pituitary morphology is affected rapidly by LL exposure. The HNS response to LL exposure may consist of changes within the first 24 h of LL found within the posterior pituitary followed later by hypertrophy of the SON MNCs.

  9. Revealing a circadian clock in captive arctic-breeding songbirds, lapland longspurs (Calcarius lapponicus), under constant illumination.

    Science.gov (United States)

    Ashley, Noah T; Ubuka, Takayoshi; Schwabl, Ingrid; Goymann, Wolfgang; Salli, Brady M; Bentley, George E; Buck, C Loren

    2014-12-01

    Most organisms in temperate or tropic regions employ the light-dark (LD) cycle as the primary Zeitgeber to synchronize circadian rhythms. At higher latitudes (>66°33'), continuous illumination during the summer presents a significant time-keeping dilemma for polar-adapted species. Lapland longspurs (Calcarius lapponicus), arctic-breeding migratory songbirds, are one of the few recorded species maintaining an intact diel rhythm in activity and plasma melatonin titers during polar summer. However, it is unknown whether rhythms are endogenous and entrain to low-amplitude polar Zeitgeber signals, such as daily variations in light intensity and the spectral composition of the sun (as measured by color temperature). Wild-caught male and female longspurs were brought into captivity, and locomotor activity was assessed using infrared detection. To examine if rhythms were endogenous, birds were exposed to constant bright light (LL; 1300 lux) or constant darkness (DD; 0.1 lux). All birds exhibited free-running activity rhythms in LL and DD, suggesting the presence of a functional circadian clock. Mean periods in LL (22.86 h) were significantly shorter than those in DD (23.5 h), in accordance with Aschoff's rule. No birds entrained to diel changes in light intensity, color temperature, or both. To examine endogenous molecular clock function, the Per2 gene was partially cloned in longspurs (llPer2) and transcripts were measured in hypothalamic tissue punches, eye, and liver using competitive polymerase chain reaction. Ocular llPer2 gene expression was periodic in LL and elevated at ZT24 (CT24) for LD or constant conditions (LL and DD), but llPer2 rhythmicity was not detected in hypothalamus or liver. Plasma melatonin was significantly lower in LL compared with LD or DD. In conclusion, rhythmic ocular Per2 expression and melatonin secretion may maintain the circadian activity rhythm across the polar day.

  10. Online feedback-controlled renal constant infusion clearances in rats.

    Science.gov (United States)

    Schock-Kusch, Daniel; Shulhevich, Yury; Xie, Qing; Hesser, Juergen; Stsepankou, Dzmitry; Neudecker, Sabine; Friedemann, Jochen; Koenig, Stefan; Heinrich, Ralf; Hoecklin, Friederike; Pill, Johannes; Gretz, Norbert

    2012-08-01

    Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique.

  11. Daily pattern of melatonin secretion in an antarctic bird, the emperor penguin, Aptenodytes forsteri: seasonal variations, effect of constant illumination and of administration of isoproterenol or propranolol.

    Science.gov (United States)

    Miché, F; Vivien-Roels, B; Pévet, P; Spehner, C; Robin, J P; Le Maho, Y

    1991-11-01

    Daily variations in circulating melatonin concentrations have been measured at monthly intervals from April to December 1986 in an Antarctic bird, the emperor penguin, Aptenodytes forsteri, maintained under natural conditions. Both duration of the elevated nighttime melatonin levels and amplitude of the day-night rhythm displays an annual variation closely related to variations in the daylength. Duration of the nocturnal peak of melatonin secretion depended upon the duration of the darkness, decreasing with increasing daylength and disappearing completely during the summer solstice. The duration of the nighttime melatonin peak melatonin increased inversely with decreasing daylength. The amplitude of the day-night rhythm decreased in such a way that the nocturnal peak of melatonin completely disappeared during the winter solstice. Three days of constant illumination in September did not suppress the nighttime peak of melatonin secretion. The response of melatonin secretion, decreasing after beta-adrenergic agonist treatment and increasing after antagonist treatment, reinforces the hypothesis that in birds the regulation of melatonin synthesis differs from that of the rat. Receptors other than beta receptors may be involved.

  12. Lactate dehydrogenase activity of rat epididymis and spermatozoa: Effect of constant light

    Directory of Open Access Journals (Sweden)

    RH Ponce

    2009-12-01

    Full Text Available During its passage through the epididymis, the gamete undergoes a process of “maturation” leading to the acquisition of its fertilizing ability. The epididymis displays regional variations in the morphology and metabolic properties of its epithelium which are relevant for the progressive development of mature sperm characteristics. The epididymis has spontaneous peristaltic contractions and receives sympathetic innervation that is modulated by melatonin, a hormone synthesized and released by the pineal gland. Constant lighting disrupts melatonin synthesis and secretion. We have studied the effect of constant light on lactate dehydrogenase (LDH; EC 1.1.1.27 and its isozyme C4 activities and protein content in whole epididymis, epididymal tissue and in spermatozoa from caput and cauda segments. Animals were exposed from birth to an illumination schedule of 14 h light: 10 h dark (group L:D. At 60 days of age one group of animals was submitted to constant light over 50 days (group L:L. In order to test the fertilizing ability, the rats of each group were mated with soliciting estrous females. The percentage of pregnancies in females mated with males maintained in L:L was remarkably lower than those in females mated with males maintained in the L:D photoperiod (44% and 88% respectively. Constant light increased protein concentration and LDH activity in caput as well as in cauda of total epididymis. On the contrary, in epididymal tissue, the protein content decreased in both epididymal sections compared with controls. When enzymatic activity was expressed in Units per spermatozoa, constant light induced a significant reduction of total LDH and LDHC4 in caput and cauda spermatozoa while LDH activity of epididymal tissue was not affected. In spite of the decrease in LDH per sperm cell when rats were exposed to constant light, in total epididymis (epididymis tissue plus sperm cells content and in spermatozoa, values of enzyme activities expressed per

  13. [Interrelations of pineal gland morpho-functional indices and immune system organs in rats exposed to natural illumination regime and continuous illumination].

    Science.gov (United States)

    Litvinenko, G I; Shurlygina, A V; Gritsyk, O B; Mel'nikova, E V; Avrorov, P A; Tendinitnik, M V; Trufakin, V A

    2014-01-01

    The objective of this investigation was to determine the complex response of the pineal gland (PG) and of the organs of the immune system in Wistar rats in response to a violation of the illumination regime in the experiment. Animals were kept under natural light regime and continuous illumination for 14 days. After that rats were sacrificed and the mass of the body, PG, gonads, thymus and spleen was measured. Thymus and spleen cell subpopulations were determined by flow cytometry. The lipofuscin content in PG was determined by measuring an autofluorescence intensity in frozen tissue sections in the wavelength range of 505-545 nm using a confocal laser scanning microscope LSM 510 META (Carl Zeiss). The correlation analysis showed an increase in the amount and the change of sign and direction of relations between the indices of the state of PG and the immune system. This indicates the up-regulation of the intensity of inter-system relationships and the change of migration and differentiation vector of immunocompetent cells.

  14. Restoration of self-sustained circadian rhythmicity by the mutant Clock allele in mice in constant illumination

    NARCIS (Netherlands)

    Spoelstra, K; Oklejewicz, M; Daan, S

    2002-01-01

    Mice mutant for the Clock gene display abnormal circadian behavior characterized by long circadian periods and a tendency to become rapidly arrhythmic in constant darkness (DID). To investigate whether this result is contingent on the absence of light, the authors studied the circadian behavior of

  15. Restoration of self-sustained circadian rhythmicity by the mutant Clock allele in mice in constant illumination

    NARCIS (Netherlands)

    Spoelstra, K; Oklejewicz, M; Daan, S

    2002-01-01

    Mice mutant for the Clock gene display abnormal circadian behavior characterized by long circadian periods and a tendency to become rapidly arrhythmic in constant darkness (DID). To investigate whether this result is contingent on the absence of light, the authors studied the circadian behavior of h

  16. A remote constant current stimulator designed for rat-robot navigation.

    Science.gov (United States)

    Chen, Xi; Xu, Kedi; Ye, Shuming; Guo, Songchao; Zheng, Xiaoxiang

    2013-01-01

    In this paper, a remote stimulator is developed for rat-robot navigation based on the technique of Brain-Computer-Interface (BCI). The stimulator can output constant current from 0 to 1000 µA, which overcome several shortages of our previous constant voltage stimulator. The constant current stimulator consists of four major components, including power supply, micro control unit (MCU), constant current source and bluetooth transceiver for downloading stimulation commands. The stimulator has a weight of about 20 g and size of 32 mm*25 mm*6mm. It has five channels of stimulation, which are connected with implanted microelectrodes in rat brain. The electrical parameters were characterized on three rats with different recovery time after brain surgery. Increasing current stimulations were applied on the dorsolateral periaqueductal gray (dlPAG) area to prove the effect of current stimulation on rat behavior.

  17. Induction of abnormal oocyte division under the constant light in the young adult rat

    Institute of Scientific and Technical Information of China (English)

    Wei Wang; Fangxiong Shi

    2012-01-01

    In order to study the effect of constant light on the ovary, 12 young adult female rats were exposed to constant light for 37 days and their estrous cycles were recorded by daily examination and the ovaries were examined histologically. The results showed that constant light induced in an abnormal and uncontrolled division of oocytes. In these divided-oocyte follicles (DOFs), two or more divided-oocytes shared one zona pellucida and usually floated freely in the follicular antrum. This fantastic phenomenon was discovered for the first time, and it was different from multioocyte follicles (MOFs) and polyovular follicles (POFs) founded in rats, humans, rabbits, mice and dogs.

  18. Effects of the infrared lamp illumination during the process of muscle fatigue in rats

    Directory of Open Access Journals (Sweden)

    Andréia Zarzour Abou-Hala

    2007-05-01

    Full Text Available In this study the effects of infrared lamp illumination during the muscle fatigue process was studied. Three different groups (n=5 were used: one control group and two treated (Infrared Lamp 780-1400nm, with the energy densities of 0.5 and 1.0 J/cm² and time of illumination of 300 seconds. The treated animals were illuminated in one point directly in the tibialis muscle, after the first tetanic contraction out of six, with an interval between each tetany. The results were registered in an electrophysiograph and the intensity of the force of contraction in grams was analysed. It was observed that the control group presented a reduction in the intensity of the force of contraction, while the treated group managed to maintain it, which was clearly evident in the energy density of 0.5 J/cm². It was concluded that the use of the infrared lamp illumination was efficient concerning resistance to muscle fatigue.Neste estudo investigamos o efeito da irradiação da lâmpada infravermelha durante o processo de fadiga muscular. Foram utilizados 3 grupos diferentes (n=5, sendo 1 grupo controle e 2 irradiados (Lâmpada de Infravermelho 780-1400nm, nas densidades de energia 0,5 e 1,0J/cm² e tempo de irradiação 300 segundos. Os animais irradiados receberam 1 irradiação em 1 ponto, diretamente no músculo tibial, após a primeira contração tetânica de um total de seis, com um intervalo entre cada tetania. Os resultados foram registrados em eletrofisiógrafo e analisado a intensidade da força de contração em gramas. Foi observado que o grupo controle apresentou uma redução na intensidade da força de contração, já os grupos irradiados conseguiram mantê-la, sendo mais evidente quando irradiado com densidade de energia (DE de 0,5J/cm². Conclui-se que a utilização da irradiação da lâmpada infravermelha é eficaz na resistência a fadiga muscular.

  19. Decreased daytime illumination leads to anxiety-like behaviors and HPA axis dysregulation in the diurnal grass rat (Arvicanthis niloticus)

    Science.gov (United States)

    Ikeno, Tomoko; Deats, Sean P.; Soler, Joel; Lonstein, Joseph S.; Yan, Lily

    2016-01-01

    The impact of ambient light on mood and anxiety is best exemplified in seasonal affective disorder, in which patients experience depression and anxiety in winter when there is less light in the environment. However, the brain mechanisms underlying light-dependent changes in affective state remain unclear. Our previous work revealed increased depression-like behaviors in the diurnal Nile grass rat (Arvicanthis niloticus) housed in a dim light-dark (dim-LD) cycle as compared to the controls housed in a bright light-dark (bright-LD) condition. As depression is often comorbid with anxiety and is associated with dysregulation of the body's stress response system, the present study examined the anxiety-like behaviors as well as indicators of the hypothalamic-pituitary-adrenal (HPA) axis functioning in the grass rats. Animals housed in dim-LD showed increased anxiety-like behaviors compared to bright-LD controls, as revealed by fewer entries and less time spent at the center in the open field test and more marbles buried during the marble-burying test. Following the marble-burying test, dim-LD animals showed higher plasma corticosterone (CORT) levels and hippocampal Fos expression. Although the daily CORT rhythm was comparable between bright-LD and dim-LD groups, the day/night variation of corticotropin-releasing hormone mRNA expression in the paraventricular nucleus was diminished in dim-LD animals. In addition, glucocorticoid receptor and mineralocorticoid receptor mRNA expression were higher in the hippocampus of dim-LD animals. The results suggest that in diurnal species, reduced daytime illumination can lead to increased anxiety-like behaviors and altered HPA axis functioning, providing insights into the link between decreased environmental illumination and negative emotion. PMID:26684510

  20. Decreased daytime illumination leads to anxiety-like behaviors and HPA axis dysregulation in the diurnal grass rat (Arvicanthis niloticus).

    Science.gov (United States)

    Ikeno, Tomoko; Deats, Sean P; Soler, Joel; Lonstein, Joseph S; Yan, Lily

    2016-03-01

    The impact of ambient light on mood and anxiety is best exemplified in seasonal affective disorder, in which patients experience depression and anxiety in winter when there is less light in the environment. However, the brain mechanisms underlying light-dependent changes in affective state remain unclear. Our previous work revealed increased depression-like behaviors in the diurnal Nile grass rat (Arvicanthis niloticus) housed in a dim light-dark (dim-LD) cycle as compared to the controls housed in a bright light-dark (bright-LD) condition. As depression is often comorbid with anxiety and is associated with dysregulation of the body's stress response system, the present study examined the anxiety-like behaviors as well as indicators of the hypothalamic-pituitary-adrenal (HPA) axis functioning in the grass rats. Animals housed in dim-LD showed increased anxiety-like behaviors compared to bright-LD controls, as revealed by fewer entries and less time spent at the center in the open field test and more marbles buried during the marble-burying test. Following the marble-burying test, dim-LD animals showed higher plasma corticosterone (CORT) levels and hippocampal Fos expression. Although the daily CORT rhythm was comparable between bright-LD and dim-LD groups, the day/night variation of corticotropin-releasing hormone mRNA expression in the paraventricular nucleus was diminished in dim-LD animals. In addition, glucocorticoid receptor and mineralocorticoid receptor mRNA expression were higher in the hippocampus of dim-LD animals. The results suggest that in diurnal species, reduced daytime illumination can lead to increased anxiety-like behaviors and altered HPA axis functioning, providing insights into the link between decreased environmental illumination and negative emotion.

  1. Social interaction and sex differences influence rat temperature circadian rhythm under LD cycles and constant light.

    Science.gov (United States)

    Cambras, T; Castejón, L; Díez-Noguera, A

    2011-06-01

    Circadian rhythms produce an efficient organization of animal behaviour over the 24h day. In some species, social cues have been found to have a role as synchronizers of these rhythms. Here, the influence of social interaction on rat circadian behaviour was investigated, addressing the question of whether cohabitation would produce a delay in the appearance of arrhythmicity under constant light conditions. To this end, the circadian rhythms of male and female rat body temperature were studied for 10days under light-dark conditions, followed by 33days under constant bright light. Half of the animals were maintained in individual cages, whilst the others were maintained in larger cages in groups of three rats of the same sex. Results showed that individual circadian rhythms under 24hour light-dark (LD) cycles were more stable and with higher amplitude in grouped than in isolated animals, and higher in males than in females. During the first days under constant light (LL), the stability of the rhythm was also higher in males than in females, but there were no differences according to the group. Moreover, we did not find significant differences in the time of circadian rhythm loss under LL, since high individual variability was found for this variable. On the other hand, female rats living in isolation showed a delayed acrophase in the circadian rhythm under LD conditions compared with those living in groups. These results suggest that cohabitation increases the internal coherence of circadian behaviour, and could be interpreted as indicating that living in isolation may induce a level of stress that disturbs manifestation of the circadian rhythm, especially in females, which are also more reactive than males to external signals.

  2. Particular features of conditioned electrodefensive reflex in white rats on background of constant magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Shust, I.V.; Galantyuk, S.I.; Cheretyanko, Yu.V.

    Study of the influence of magnetic fields upon the higher nervous activity of man and animals has long been attracting the attention of researchers. It is indicated in the literature that magnetic fields inhibit development of conditioned reflexes in planarians, fishes, and mammals. However, there are data of opposite nature as well, indicating accelerated development of the avoidance reflex in animals exposed previously to a magnetic field. Researchers studied formation of a conditioned electrodefensive reflex (CER) in white rats exposed to a constant magnetic field (CMF), and the influence of a vitamin preparation - galascorbin - on formation of the CER in animals exposed to a CMF.

  3. Imaging dendritic spines of rat primary hippocampal neurons using structured illumination microscopy.

    Science.gov (United States)

    Schouten, Marijn; De Luca, Giulia M R; Alatriste González, Diana K; de Jong, Babette E; Timmermans, Wendy; Xiong, Hui; Krugers, Harm; Manders, Erik M M; Fitzsimons, Carlos P

    2014-05-04

    Dendritic spines are protrusions emerging from the dendrite of a neuron and represent the primary postsynaptic targets of excitatory inputs in the brain. Technological advances have identified these structures as key elements in neuron connectivity and synaptic plasticity. The quantitative analysis of spine morphology using light microscopy remains an essential problem due to technical limitations associated with light's intrinsic refraction limit. Dendritic spines can be readily identified by confocal laser-scanning fluorescence microscopy. However, measuring subtle changes in the shape and size of spines is difficult because spine dimensions other than length are usually smaller than conventional optical resolution fixed by light microscopy's theoretical resolution limit of 200 nm. Several recently developed super resolution techniques have been used to image cellular structures smaller than the 200 nm, including dendritic spines. These techniques are based on classical far-field operations and therefore allow the use of existing sample preparation methods and to image beyond the surface of a specimen. Described here is a working protocol to apply super resolution structured illumination microscopy (SIM) to the imaging of dendritic spines in primary hippocampal neuron cultures. Possible applications of SIM overlap with those of confocal microscopy. However, the two techniques present different applicability. SIM offers higher effective lateral resolution, while confocal microscopy, due to the usage of a physical pinhole, achieves resolution improvement at the expense of removal of out of focus light. In this protocol, primary neurons are cultured on glass coverslips using a standard protocol, transfected with DNA plasmids encoding fluorescent proteins and imaged using SIM. The whole protocol described herein takes approximately 2 weeks, because dendritic spines are imaged after 16-17 days in vitro, when dendritic development is optimal. After completion of the

  4. [The influence of constant lightening on physiological parameters of rats homeostasis depending on time beginning of exposure].

    Science.gov (United States)

    Lotosh, T A; Vinogradova, I A; Iliukha, V A; Khizhkin, E A

    2013-06-01

    The influence of constant lightening on biomarkers of ageing and rates of male rats aging was studied. It was revealed that the maintenance of rats in the constant lightening regime starting from the age of one month results in accelerated ageing of the organism, the reduction of the phases progressive and stable growth, early occurrence of presenile and senile periods, to the earlier occurrence of water-and-salt metabolism imbalance, accelerate the process of "aging" of the antioxidant system in comparison with the rates of the control group. On the contrary, the maintenance of rats in the constant lightening regime starting from the age of fourteen months slows ageing of the organism, increases body growth, delays appearance of pathological changes in the urine, slows down the "aging" of the enzymatic components of the antioxidant system.

  5. Constant pressure fluid infusion into rat neocortex from implantable microfluidic devices

    Science.gov (United States)

    Retterer, S. T.; Smith, K. L.; Bjornsson, C. S.; Turner, J. N.; Isaacson, M. S.; Shain, W.

    2008-12-01

    Implantable electrode arrays capable of recording and stimulating neural activity with high spatial and temporal resolution will provide a foundation for future brain computer interface technology. Currently, their clinical impact has been curtailed by a general lack of functional stability, which can be attributed to the acute and chronic reactive tissue responses to devices implanted in the brain. Control of the tissue environment surrounding implanted devices through local drug delivery could significantly alter both the acute and chronic reactive responses, and thus enhance device stability. Here, we characterize pressure-mediated release of test compounds into rat cortex using an implantable microfluidic platform. A fixed volume of fluorescent cell marker cocktail was delivered using constant pressure infusion at reservoir backpressures of 0, 5 and 10 psi. Affected tissue volumes were imaged and analyzed using epifluorescence and confocal microscropies and quantitative image analysis techniques. The addressable tissue volume for the 5 and 10 psi infusions, defined by fluorescent staining with Hoescht 33342 dye, was significantly larger than the tissue volume addressed by simple diffusion (0 psi) and the tissue volume exhibiting insertion-related cell damage (stained by propidium iodide). The results demonstrate the potential for using constant pressure infusion to address relevant tissue volumes with appropriate pharmacologies to alleviate reactive biological responses around inserted neuroprosthetic devices.

  6. Successive Generations in a Rat Model Respond Differently to a Constant Obesogenic Environment.

    Science.gov (United States)

    Tait, Alice H; Raubenheimer, David; Green, Mark P; Cupido, Cinda L; Gluckman, Peter D; Vickers, Mark H

    2015-01-01

    Research has shown that if a mother experiences a transitory perturbation to her environment during pregnancy or lactation, there are transgenerational consequences often involving a disordered metabolic phenotype in first generation offspring with recovery across subsequent generations. In contrast, little is known about the nature of the transgenerational response of offspring when a mother experiences a perturbation that is not transitory but instead persists across generations. Our study, using a rat model, subjected the parental generation to a change in environment and concomitant shift from a grain-based to obesogenic diets to generate an adipose phenotype in first generation offspring emulating a common scenario in human urbanisation and migration. We then investigated whether the obese phenotype was stable across generations when maintained in the transitioned environment, and whether dietary macronutrient balance affected the response. We found that second and third generation offspring had a reduced body fat to lean mass ratio and a reduced appetite relative to first generation offspring, irrespective of dietary macronutrient balance. The trajectory of this response is suggestive of a reduction in chronic disease risk across generations. This is one of the first studies, to our knowledge, to investigate the transgenerational response following parental transition to a persistent obesogenic environment, and to demonstrate that successive generations respond differently to this constant environment.

  7. Successive Generations in a Rat Model Respond Differently to a Constant Obesogenic Environment.

    Directory of Open Access Journals (Sweden)

    Alice H Tait

    Full Text Available Research has shown that if a mother experiences a transitory perturbation to her environment during pregnancy or lactation, there are transgenerational consequences often involving a disordered metabolic phenotype in first generation offspring with recovery across subsequent generations. In contrast, little is known about the nature of the transgenerational response of offspring when a mother experiences a perturbation that is not transitory but instead persists across generations. Our study, using a rat model, subjected the parental generation to a change in environment and concomitant shift from a grain-based to obesogenic diets to generate an adipose phenotype in first generation offspring emulating a common scenario in human urbanisation and migration. We then investigated whether the obese phenotype was stable across generations when maintained in the transitioned environment, and whether dietary macronutrient balance affected the response. We found that second and third generation offspring had a reduced body fat to lean mass ratio and a reduced appetite relative to first generation offspring, irrespective of dietary macronutrient balance. The trajectory of this response is suggestive of a reduction in chronic disease risk across generations. This is one of the first studies, to our knowledge, to investigate the transgenerational response following parental transition to a persistent obesogenic environment, and to demonstrate that successive generations respond differently to this constant environment.

  8. Synchrotron microbeam radiation therapy for rat brain tumor palliation—influence of the microbeam width at constant valley dose

    Science.gov (United States)

    Serduc, Raphaël; Bouchet, Audrey; Bräuer-Krisch, Elke; Laissue, Jean A.; Spiga, Jenny; Sarun, Sukhéna; Bravin, Alberto; Fonta, Caroline; Renaud, Luc; Boutonnat, Jean; Siegbahn, Erik Albert; Estève, François; Le Duc, Géraldine

    2009-11-01

    To analyze the effects of the microbeam width (25, 50 and 75 µm) on the survival of 9L gliosarcoma tumor-bearing rats and on toxicity in normal tissues in normal rats after microbeam radiation therapy (MRT), 9L gliosarcomas implanted in rat brains, as well as in normal rat brains, were irradiated in the MRT mode. Three configurations (MRT25, MRT50, MRT75), each using two orthogonally intersecting arrays of either 25, 50 or 75 µm wide microbeams, all spaced 211 µm on center, were tested. For each configuration, peak entrance doses of 860, 480 and 320 Gy, respectively, were calculated to produce an identical valley dose of 18 Gy per individual array at the center of the tumor. Two, 7 and 14 days after radiation treatment, 42 rats were killed to evaluate histopathologically the extent of tumor necrosis, and the presence of proliferating tumors cells and tumor vessels. The median survival times of the normal rats were 4.5, 68 and 48 days for MRT25, 50 and 75, respectively. The combination of the highest entrance doses (860 Gy per array) with 25 µm wide beams (MRT25) resulted in a cumulative valley dose of 36 Gy and was excessively toxic, as it led to early death of all normal rats and of ~50% of tumor-bearing rats. The short survival times, particularly of rats in the MRT25 group, restricted adequate observance of the therapeutic effect of the method on tumor-bearing rats. However, microbeams of 50 µm width led to the best median survival time after 9L gliosarcoma MRT treatment and appeared as the better compromise between tumor control and normal brain toxicity compared with 75 µm or 25 µm widths when used with a 211 µm on-center distance. Despite very high radiation doses, the tumors were not sterilized; viable proliferating tumor cells remained present at the tumor margin. This study shows that microbeam width and peak entrance doses strongly influence tumor responses and normal brain toxicity, even if valley doses are kept constant in all groups. The use of

  9. Synchrotron microbeam radiation therapy for rat brain tumor palliation-influence of the microbeam width at constant valley dose

    Energy Technology Data Exchange (ETDEWEB)

    Serduc, Raphael; Fonta, Caroline; Renaud, Luc [Universite de Toulouse, UPS, Centre de Recherche Cerveau et Cognition (France); Bouchet, Audrey; Braeuer-Krisch, Elke; Sarun, Sukhena; Bravin, Alberto; Le Duc, Geraldine [European Synchrotron Radiation Facility, F38043 Grenoble (France); Laissue, Jean A [Institute of Pathology, University of Bern (Switzerland); Spiga, Jenny [Department of Physics, University of Cagliari, s.p. Monserrato-Sestu, Monserrato (Canada) 09042 (Italy); Boutonnat, Jean [TIMC lab, UMR CNRS 5525, Univ Joseph Fourier, CHU, Grenoble (France); Siegbahn, Erik Albert [Department of Medical Physics, Karolinska Universitetssjukhuset, 17176 Stockholm (Sweden); Esteve, Francois [INSERM U836, Equipe 6, Institut des Neurosciences de Grenoble, 38043 Grenoble Cedex (France)], E-mail: raph.serduc@gmail.com

    2009-11-07

    To analyze the effects of the microbeam width (25, 50 and 75 {mu}m) on the survival of 9L gliosarcoma tumor-bearing rats and on toxicity in normal tissues in normal rats after microbeam radiation therapy (MRT), 9L gliosarcomas implanted in rat brains, as well as in normal rat brains, were irradiated in the MRT mode. Three configurations (MRT25, MRT50, MRT75), each using two orthogonally intersecting arrays of either 25, 50 or 75 {mu}m wide microbeams, all spaced 211 {mu}m on center, were tested. For each configuration, peak entrance doses of 860, 480 and 320 Gy, respectively, were calculated to produce an identical valley dose of 18 Gy per individual array at the center of the tumor. Two, 7 and 14 days after radiation treatment, 42 rats were killed to evaluate histopathologically the extent of tumor necrosis, and the presence of proliferating tumors cells and tumor vessels. The median survival times of the normal rats were 4.5, 68 and 48 days for MRT25, 50 and 75, respectively. The combination of the highest entrance doses (860 Gy per array) with 25 {mu}m wide beams (MRT25) resulted in a cumulative valley dose of 36 Gy and was excessively toxic, as it led to early death of all normal rats and of {approx}50% of tumor-bearing rats. The short survival times, particularly of rats in the MRT25 group, restricted adequate observance of the therapeutic effect of the method on tumor-bearing rats. However, microbeams of 50 {mu}m width led to the best median survival time after 9L gliosarcoma MRT treatment and appeared as the better compromise between tumor control and normal brain toxicity compared with 75 {mu}m or 25 {mu}m widths when used with a 211 {mu}m on-center distance. Despite very high radiation doses, the tumors were not sterilized; viable proliferating tumor cells remained present at the tumor margin. This study shows that microbeam width and peak entrance doses strongly influence tumor responses and normal brain toxicity, even if valley doses are kept constant in

  10. Constant expression of cyclooxygenase-2 gene in prostate and the lower urinary tract of estrogen-treated male rats.

    Science.gov (United States)

    Luo, C; Strauss, L; Ristimäki, A; Streng, T; Santti, R

    2001-01-01

    Expression of cyclooxygenase-2 (E. C. 1.14.99.1) in prostate and the lower urinary tract (LUT) of the neonatally estrogenized male rat has been studied by using a COX-2's PCR fragment of 724 nt spanning 3 introns and a 478nt internal standard for quantitative RT-PCR. The same fragment of 724 nt was used for RNA probe in Northern hybridization. Neonatal estrogenization (10 microg/day of diethylstilbestrol on days 1-5) had no effect on COX-2 expression in prostatic urethra, prostatic lobes, or bladder. Acute estrogen treatment of castrated animals did not induce COX-2 expression, either. In addition the differential expression of basal level of COX-2 in the different lobes of prostate in normal rat was demonstrated. Our results suggest a constant expression of COX-2 gene in prostate and the lower urinary tract of the neonatally estrogenized (neoDES) rats. The present study indicates that the increased expression of COX-2 is probably not essential for the estrogen-driven development of stromal inflammation or hyperplastic and dysplastic alterations in the prostate of neoDES rats.

  11. Effects of endurance training on reduction of plasma glucose during high intensity constant and incremental speed tests in Wistar rats.

    Science.gov (United States)

    Abreu, P; Vitzel, K F; Monteiro, I C C R; Lima, T I; Queiroz, A N; Leal-Cardoso, J H; Hirabara, S M; Ceccatto, V M

    2016-10-24

    The aim of this research was to investigate the effects of endurance training on reduction of plasma glucose during high intensity constant and incremental speed tests in Wistar rats. We hypothesized that plasma glucose might be decreased in the exercised group during heavy (more intense) exercise. Twenty-four 10-week-old male Wistar rats were randomly assigned to sedentary and exercised groups. The prescription of endurance exercise training intensity was determined as 60% of the maximum intensity reached at the incremental speed test. The animals were trained by running on a motorized treadmill, five days/week for a total period of 67 weeks. Plasma glucose during the constant speed test in the exercised group at 20 m/min was reduced at the 14th, 21st and 28th min compared to the sedentary group, as well at 25 m/min at the 21st and 28th min. Plasma glucose during the incremental speed test was decreased in the exercised group at the moment of exhaustion (48th min) compared to the sedentary group (27th min). Endurance training positively modulates the mitochondrial activity and capacity of substrate oxidation in muscle and liver. Thus, in contrast to other studies on high load of exercise, the effects of endurance training on the decrease of plasma glucose during constant and incremental speed tests was significantly higher in exercised than in sedentary rats and associated with improved muscle and hepatic oxidative capacity, constituting an important non-pharmacological intervention tool for the prevention of insulin resistance, including type 2 diabetes mellitus.

  12. Effects of endurance training on reduction of plasma glucose during high intensity constant and incremental speed tests in Wistar rats

    Directory of Open Access Journals (Sweden)

    P. Abreu

    Full Text Available The aim of this research was to investigate the effects of endurance training on reduction of plasma glucose during high intensity constant and incremental speed tests in Wistar rats. We hypothesized that plasma glucose might be decreased in the exercised group during heavy (more intense exercise. Twenty-four 10-week-old male Wistar rats were randomly assigned to sedentary and exercised groups. The prescription of endurance exercise training intensity was determined as 60% of the maximum intensity reached at the incremental speed test. The animals were trained by running on a motorized treadmill, five days/week for a total period of 67 weeks. Plasma glucose during the constant speed test in the exercised group at 20 m/min was reduced at the 14th, 21st and 28th min compared to the sedentary group, as well at 25 m/min at the 21st and 28th min. Plasma glucose during the incremental speed test was decreased in the exercised group at the moment of exhaustion (48th min compared to the sedentary group (27th min. Endurance training positively modulates the mitochondrial activity and capacity of substrate oxidation in muscle and liver. Thus, in contrast to other studies on high load of exercise, the effects of endurance training on the decrease of plasma glucose during constant and incremental speed tests was significantly higher in exercised than in sedentary rats and associated with improved muscle and hepatic oxidative capacity, constituting an important non-pharmacological intervention tool for the prevention of insulin resistance, including type 2 diabetes mellitus.

  13. Variations in illumination, closed wall transparency and/or extramaze space influence both baseline anxiety and response to diazepam in the rat elevated plus-maze.

    Science.gov (United States)

    Violle, Nicolas; Balandras, Frédérique; Le Roux, Yves; Desor, Didier; Schroeder, Henri

    2009-10-12

    Numerous methodological-related variables have been demonstrated to influence the baseline anxiety level of rodents exposed to the elevated plus-maze (EPM), raising questions about the sensitivity of this test for the detection of the effects of anxiolytic drugs. Thus, the present study was designed (1) to assess the combined effects of illumination (40-lx red or white light), closed wall type (walls made of translucent or opaque material) and extramaze space size (small or spacious experimental room) on rat behaviour, and (2) to investigate the effects of such parameters on the relevance of the maze for detecting the effects of diazepam orally administrated at the anxiolytic dose of 3 mg/kg. Results indicate that illumination and closed wall type are two main independent parameters that are able to modify the open arm avoidance. Moreover, the closed wall type interacts with the extramaze space size since the reduction of the open arm exploration induced by opaque closed walls is two-fold stronger in the spacious experimental room than in the small one. Finally, the diazepam anxiolytic activity is significantly detected in our laboratory in specific EPM conditions (maze with opaque walls, use of a red light, maze located in a spacious experimental room). In conclusion, the present study demonstrates that an inappropriate baseline anxiety level due to the methodological use of the EPM can dramatically reduce the sensitivity of the maze for the detection of benzodiazepine-related compounds. This study also provides new insights into the perception of the EPM open space in rats.

  14. [Effect of a strong constant magnetic field and a hypomagnetic surrounding medium on histochemical indices of albino rat liver].

    Science.gov (United States)

    Shust, I V; Kostinik, I M

    1975-01-01

    The paper presents histochemical measurements of the liver of white rats exposed to strong and weak constant magnetic fields. A repeated influence (30 min a day) of the strong magnetic field of 912 ersted for 16 days inhibits synthetic processes in the liver tissue. A more prolonged (30 days) exposure to the field produces insignificant histochemical changes which seem to be induced by the occuring compensatory reaction. It is shown that a month long stay of animals in the environment shielded from the geomagnetic field may enhance synthetic processes in some cells and inhibit them in others.

  15. Interrelations and circadian changes of electroencephalogram frequencies under baseline conditions and constant sleep pressure in the rat.

    Science.gov (United States)

    Yasenkov, R; Deboer, T

    2011-04-28

    Similar to the nap-protocols applied in humans, the repeated short-sleep deprivation protocol in rats stabilizes slow-wave activity (SWA, 0.5-4 Hz) in the non-rapid eye movement (NREM) sleep electroencephalogram (EEG), thus reflecting a constant sleep pressure or sleep homeostatic level, whereas higher frequencies (7-25 Hz) in these conditions preserve their daily rhythm, therefore demonstrating a strong input from an endogenous circadian clock. How different EEG frequencies in rapid eye movement (REM) sleep and waking respond to these constant conditions, how they interrelate to each other within the different vigilance states, and which component of sleep regulation (homeostatic or circadian) is involved, remain unknown. To answer these questions, we applied power spectral analysis and correlation analysis to 1 Hz bin EEG frequency data for different vigilance states in freely moving rats in constant darkness, under baseline conditions and during the repeated short-sleep deprivation protocol. Our analysis suggests that (1) 0.5-5 Hz frequencies in NREM sleep and higher frequencies in REM sleep (above 19 Hz) and waking (above 10 Hz) are sleep-dependent, and thus seem to be under control of the sleep homeostat, while (2) faster frequencies in the NREM sleep EEG (7-25 Hz) and 3-7 Hz activity in the REM sleep EEG are under strong influence of the endogenous circadian clock. Theta activity in waking (5-7 Hz) seems to reflect both circadian and behavior dependent influences. NREM sleep EEG frequencies between 9 and 14 Hz showed both homeostatic and circadian components in their behavior. Thus, frequencies in the EEG of the different vigilance states seem to represent circadian and homeostatic components of sleep regulatory mechanisms, where REM sleep and waking frequency ranges behave similarly to each other and differently from NREM sleep frequencies.

  16. [Effects of a short-term diet of precooked corn flour on the vaginal cycle, in rats placed in various conditions of environmental illumination].

    Science.gov (United States)

    Lopez de Onate, R; Giammanco, S; Carollo, F; Ernandes, M; Paderni, M A

    1989-03-01

    The aim of this research is to study the effects of a diet almost devoid of tryptophan, which is given by a feeding with precooked yellow corn meal (corn mush), on the alterations of the estrous cycle of animals in several conditions of environmental lighting. Indeed, it is known that cerebral serotonin influences the releasing of LH and consequently the ovulation. The different types of environmental lighting are: 1) Natural (alternating Day-Night = L/D). 2) Continuous dark (D/D). 3) Continuous light by sodium steams (L/L sodium). 4) Continuous light by fluorescent neon tubes (L/L neon). The muricide behaviour is studied by comparison rat-mouse. The feeding with precooked yellow corn meal (diet lacking of tryptophan) unchains in the 100% of the observations the CEA (Constant Estrous Anovulatory), and significantly shrinks the estral cycle in the female Wistar Rat in several conditions of environmental lighting.

  17. Gestation under chronic constant light leads to extensive gene expression changes in the fetal rat liver.

    Science.gov (United States)

    Spichiger, Carlos; Torres-Farfan, Claudia; Galdames, Hugo A; Mendez, Natalia; Alonso-Vazquez, Pamela; Richter, Hans G

    2015-12-01

    Recent reports account for altered metabolism in adult offspring from pregnancy subjected to abnormal photoperiod, suggesting fetal programming of liver physiology. To generate a pipeline of subsequent mechanistic experiments addressing strong candidate genes, here we investigated the effects of constant gestational light on the fetal liver transcriptome. At 10 days of gestation, dams were randomized in two groups (n = 7 each): constant light (LL) and normal photoperiod (12 h light/12 h dark; LD). At 18 days of gestation, RNA was isolated from the fetal liver and subjected to DNA microarray (Affymetrix platform for 28,000 genes). Selected differential mRNAs were validated by quantitative PCR (qPCR), while integrated transcriptional changes were analyzed with Ingenuity Pathway Analysis and other bioinformatics tools. Comparison of LL relative to LD fetal liver led to the following findings. Significant differential expression was found for 3,431 transcripts (1,960 upregulated and 1,471 downregulated), with 393 of them displaying ≥ 1.5-fold change. We validated 27 selected transcripts by qPCR, which displayed fold-change values highly correlated with microarray (r(2) = 0.91). Different markers of nonalcoholic fatty liver disease were either upregulated (e.g., Ndn and Pnpla3) or downregulated (e.g., Gnmt, Bhmt1/2, Sult1a1, Mpo, and Mat1a). Diverse pathways were altered, including hematopoiesis, coagulation cascade, complement system, and carbohydrate and lipid metabolism. The microRNAs 7a-1, 431, 146a, and 153 were upregulated, while the abundant hepatic miRNA 122 was downregulated. Constant gestational light induced extensive modification of the fetal liver transcriptome. A number of differentially expressed transcripts belong to fundamental functional pathways, potentially contributing to long-term liver disease.

  18. Hotsphere illumination

    Science.gov (United States)

    Razavi, Bahar S.; Kuzyakov, Yakov

    2016-04-01

    Soils are the most heterogeneous parts of the biosphere, with an extremely high differentiation of properties and processes at all spatial and temporal scales. Importance of the hotspheres such as rhizosphere, detritusphere, porosphere (including drilosphere and biopores), hyphasphere and spermosphere, calls for spatially explicit methods to illuminate distribution of microbial activities in these hotspheres (Kuzyakov and Blagodatskaya, 2015). Zymography technique has previously been adapted to visualize the spatial dynamics of enzyme activities in rhizosphere (Spohn and Kuzyakov, 2014). Here, we further developed soil zymography to obtain a higher resolution of enzyme activities by enabling direct contact of substrate-saturated membranes with soil. For the first time, we aimed at quantitative imaging of enzyme activities in various hotspheres. We calculated and compared percentage of enzymatic hotspots of five hotspheres: spermosphere, rhizosphere, detritusphere, drilosphere and biopores. Spatial distribution of activities of two enzymes: β-glucosidase and leucine amino peptidase were analyzed in the spermosphere, rhizosphere and detritusphere of maize and lentil. Zymography has been done 3 days (spermosphere), 14 days (rhizosphere) after sowing and 21 days after cutting plant (detritusphere). Spatial resolution of fluorescent images was improved by direct application fluorogenically labelled substrates on the soil surface. Such improvement enabled to visualize enzyme distribution of mycorrhiza hypha on the rhizobox surface. Further, to visualize the 2D distribution of the enzyme activities in porosphere, we placed earthworms (Lumbricus terrestris), (drilosphere) and ground beetle species Platynus dorsalis Pont. (Coleoptera; Carabidae), (biopore), in transparent boxes for 2weeks. The developed in situ zymography visualized the heterogeneity of enzyme activities along and across the roots. Spatial patterns of enzyme activities as a function of distance along the

  19. Tissue vitamin concentrations are maintained constant by changing the urinary excretion rate of vitamins in rats' restricted food intake.

    Science.gov (United States)

    Shibata, Katsumi; Fukuwatari, Tsutomu

    2014-01-01

    We previously reported that mild food restriction induces a reduction in tryptophan-nicotinamide conversion, which helps to explain why death secondary to pellagra is pandemic during the hungry season. In this study, we investigated the levels of B-group vitamins in the liver, kidney, blood, and urine in rats that underwent gradual restriction of food intake (80, 60, 40, and 20% restriction vs. ad libitum food intake). No significant differences in the B-group vitamin concentrations (mol/g tissue) in the liver and kidney were observed at any level of food restriction. However, the urine excretion rates exhibited some characteristic phenomena that differed by vitamin. These results show that the tissue concentrations of B-group vitamins were kept constant by changing the urinary elimination rates of vitamins under various levels of food restriction. Only vitamin B12 was the only (exception).

  20. Protective effect of maternal prenatal melatonin administration on rat pups born to mothers submitted to constant light during gestation

    Directory of Open Access Journals (Sweden)

    C.D. Cisternas

    2010-09-01

    Full Text Available We studied the effects of adverse conditions such as constant light (LL on the circadian rhythm of malate (MDH, EC 1.1.1.37 and lactate (LDH, EC 1.1.1.27 dehydrogenase activities of the testes of male Wistar rats on postnatal day 28 (PN28, anxiety-like behavior (elevated plus-maze test at PN60 and sexual behavior at PN120. The rats were assigned to mother groups on day 10 of pregnancy: control (12-h light/dark, LL (light from day 10 to 21 of pregnancy, and LL+Mel (LL and sc injection to the mothers of a daily dose of melatonin, 1 mg/kg body weight at circadian time 12, from day 17 to 21 of pregnancy. LL offspring did not show circadian rhythms of MDH (N = 62 and LDH (N = 63 activities (cosinor and ANOVA-LSD Fisher. They presented a 44.7% decrease in open-arm entries and a 67.9% decrease in time (plus-maze test, N = 15, P < 0.001, Mann-Whitney U-test and Kruskal-Wallis test, an increase in mounting (94.4%, intromission (94.5% and ejaculation (56.6% latencies (N = 12, P < 0.01, Mann-Whitney U-test and Kruskal-Wallis test and lower numbers of these events (61, 59 and 73%, respectively; P < 0.01, N = 12 compared to controls. The offspring of the LL+Mel group presented MDH and LDH circadian rhythms (P < 0.05, N = 50, cosinor and ANOVA-LSD Fisher, anxiety-like and sexual behaviors similar to control. These findings supported the importance of the melatonin signal and provide evidence for the protective effects of hormones on maternal programming during gestation. This protective action of melatonin is probably related to its entrainment capacity, favoring internal coupling of the fetal multioscillatory system.

  1. A comparison of two methods for calculating CR (time constant) during studies of arterial blood flow in rats.

    Science.gov (United States)

    Sasaoka, K; Ogawa, K

    1990-11-01

    Some of our earlier reports have dealt with experiments on the central caudal arteries of a series of anesthetized rats. The results of these experiments were expressed by a relationship derived from the Windkessel theory where f(t) = alpha dz(t)/dt + beta z(t). When this theory is used, the measured blood flow forms f(t) and calculated wave forms alpha dz(t)/dt + beta z(t) agree closely. In these studies, we discovered that, when blood flow adz(t)/dt + beta z(t) agree closely. In these studies, we discovered that, when blood flow decreases, CR (time constant tau, the product of the blood vessel compliance C and the peripheral resistance R) values increase and vary widely. In the present study, 1) we investigated changes in CR when blood flow increases, and, 2) the method of least squares was used in calculating the formula given above. We achieved a better conformity between measured blood flow and calculated blood flow and perceived a clearer relationship between mean blood flow and CR than when they were calculated by the old method.

  2. Fibre illumination system

    DEFF Research Database (Denmark)

    2012-01-01

    Source: EP2426402A The invention relates to a fibre illumination module and system for the collection and delivery of daylight for illumination purposes. The fibre illumination module comprises a plurality of collector elements, each collector element comprising an input fibre having a first end......-directional arrangement. The fibre illumination system comprises a fibre illumination module of the above-mentioned type. By the invention, daylight may be exploited for the illumination of remote interior spaces of buildings in order to save energy, and improve the well-being of users in both housing and working...

  3. Chromatic illumination discrimination ability reveals that human colour constancy is optimised for blue daylight illuminations.

    Science.gov (United States)

    Pearce, Bradley; Crichton, Stuart; Mackiewicz, Michal; Finlayson, Graham D; Hurlbert, Anya

    2014-01-01

    The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow) and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K), all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed.

  4. Chromatic illumination discrimination ability reveals that human colour constancy is optimised for blue daylight illuminations.

    Directory of Open Access Journals (Sweden)

    Bradley Pearce

    Full Text Available The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K, all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed.

  5. Realtime global illumination using compressed pre-computed indirect illumination textures

    DEFF Research Database (Denmark)

    Bahnsen, Chris; Martin dit Neuville, Antoine; Pedersen, Casper

    2012-01-01

    In this paper, we present a way to render images in real time, with both direct and indirect illumination. Our approach uses precomputed indirect illumination images, produced at certain intervals, which need not be constant. When rendering a scene, the two closest images are then interpolated...... and added to the direct illumination to produce the total illumination. Depending on the type of image produced, the algorithm allows a camera to move, and even objects to be added or modified at runtime to some extent. Finally, we will see that the amount of data to store and process can also be reduced...

  6. Papel da luminosidade do biotério no comportamento do rato no labirinto em cruz elevado Role of vivarium illumination in rat behavior in the elevated plus-maze

    Directory of Open Access Journals (Sweden)

    Raquel Martinez

    2005-08-01

    Full Text Available Há pouca informação sobre o efeito dos ambientes onde os ratos são mantidos antes de testes. Para investigar o efeito da iluminação do biotério, ratos Wistar machos foram submetidos a um período de 96 h de iluminação contínua, escuridão contínua ou um ciclo claro escuro de 12:12 h e testados no labirinto em cruz elevado em uma sala iluminada (150 lux ou escura (0 lux. Os resultados mostram que nem a iluminação contínua nem a escuridão contínua do biotério afetam o comportamento dos ratos, quando comparados aos sujeitos mantidos no ciclo claro-escuro de 12 h. A condição de luminosidade durante o teste, no entanto, foi importante: independentemente da condição de iluminação do biotério, os animais testados no escuro exploraram mais os braços abertos do labirinto, um resultado já relatado na literatura e interpretado como diminuição da ansiedade nesse aparato.There is little information about the environments where rats are kept before being tested. In order to investigate the role of vivarium illumination, male Wistar rats were submitted to a 96-h period of continuous illumination, continuous dark or a 12:12 h light/dark cycle and tested in the elevated plus-maze in a lit (150 lux or a dark room (0 lux. Results showed that neither vivarium illumination nor darkness for 96 h altered the rats' behavior in comparison to that of rats kept under the 12-h light/dark cycle. Luminosity during the test, however, was important: no matter what the vivarium illumination was, rats tested in the dark room explored more the open arms of the maze, an already reported result which is interpreted as decreased anxiety in this apparatus.

  7. Research on Spacecraft Illumination

    Directory of Open Access Journals (Sweden)

    Bo Cai

    2011-07-01

    Full Text Available Illumination analysis of spacecraft is very important. This paper firstly introduces the importance of spacecraft illumination analysis in aerospace fields and points out that illumination conditions will influence the design of shape of spacecraft body and the installation of spacecraft equipments. Then, it discusses two methods for analyzing spacecraft solar-panel shadow and illumination conditions: ray tracing illumination algorithm and polyhedral mesh contour edge projection algorithm and compares their efficiency and feasibility. Shadow area and solar area are computed of every cell on solar panels. We designed solar panel single-axis rotation experiment to validate the proposed algorithm. The experimental results show that contour edge projection algorithm has fine accuracy and costs less time. For detailed illumination information, we apply a practical segment clipping algorithm after some comparisons.

  8. Grouping Illumination Frameworks

    Science.gov (United States)

    Zdravkovic, Suncica; Economou, Elias; Gilchrist, Alan

    2012-01-01

    According to Koffka (1935), the lightness of a target surface is determined by the relationship between the target and the illumination frame of reference to which it belongs. However, each scene contains numerous illumination frames, and judging each one separately would lead to an enormous amount of computing. Grouping those frames that are in…

  9. Midwestern Medieval Illuminations Archives.

    Science.gov (United States)

    Purdue Univ., Lafayette, IN. Audio-Visual Center.

    This catalog lists the slides of medieval manuscript illuminations available at the Midwestern Medieval Illuminations Archives at the Purdue University Audio-Visual Center. Instructions are provided for ordering slides from the Center. Slide sets are listed by title, with citations including catalog number, rental price, producer/vendor code,…

  10. Contrast edge colors under different natural illuminations.

    Science.gov (United States)

    Nieves, Juan Luis; Nascimento, Sérgio M C; Romero, Javier

    2012-02-01

    Essential to sensory processing in the human visual system is natural illumination, which can vary considerably not only across space but also along the day depending on the atmospheric conditions and the sun's position in the sky. In this work, edges derived from the three postreceptoral Luminance, Red-Green, and Blue-Yellow signals were computed from hyperspectral images of natural scenes rendered with daylights of Correlated Color Temperatures (CCTs) from 2735 to 25,889 K; for low CCT, the same analysis was performed using Planckian illuminants up to 800 K. It was found that average luminance and chromatic edge contrasts were maximal for low correlated color temperatures and almost constants above 10,000 K. The magnitude of these contrast changes was, however, only about 2% across the tested daylights. Results suggest that the postreceptoral opponent and nonopponent color vision mechanisms produce almost constant responses for color edge detection under natural illumination.

  11. Fibre illumination system

    DEFF Research Database (Denmark)

    2012-01-01

    Source: EP2426402A The invention relates to a fibre illumination module and system for the collection and delivery of daylight for illumination purposes. The fibre illumination module comprises a plurality of collector elements, each collector element comprising an input fibre having a first end...... the proximal end of the collection optics into the first end of the input fibre, each collector element having a principal axis for the collection of light defining an optical axis of the collector element. The optical axes of the collector elements are arranged in a radially outward pointing multi...

  12. Illumination in diverse codimensions

    Science.gov (United States)

    Banks, David C.

    1994-01-01

    This paper derives a model of diffuse and specular illumination in arbitrarily large dimensions, based on a few characteristics of material and light in three-space. It then describes how to adjust for the anomaly of excess brightness in large codimensions. If a surface is grooved or furry, it can be illuminated with a hybrid model that incorporates both the one dimensional geometry (the grooves or fur) and the two dimensional geometry (the surface).

  13. Natural light illumination system.

    Science.gov (United States)

    Whang, Allen Jong-Woei; Chen, Yi-Yung; Yang, Shu-Hua; Pan, Po-Hsuan; Chou, Kao-Hsu; Lee, Yu-Chi; Lee, Zong-Yi; Chen, Chi-An; Chen, Cheng-Nan

    2010-12-10

    In recent years, green energy has undergone a lot of development and has been the subject of many applications. Many research studies have focused on illumination with sunlight as a means of saving energy and creating healthy lighting. Natural light illumination systems have collecting, transmitting, and lighting elements. Today, most daylight collectors use dynamic concentrators; these include Sun tracking systems. However, this design is too expensive to be cost effective. To create a low-cost collector that can be easily installed on a large building, we have designed a static concentrator, which is prismatic and cascadable, to collect sunlight for indoor illumination. The transmission component uses a large number of optical fibers. Because optical fibers are expensive, this means that most of the cost for the system will be related to transmission. In this paper, we also use a prismatic structure to design an optical coupler for coupling n to 1. With the n-to-1 coupler, the number of optical fibers necessary can be greatly reduced. Although this new natural light illumination system can effectively guide collected sunlight and send it to the basement or to other indoor places for healthy lighting, previously there has been no way to manage the collected sunlight when lighting was not desired. To solve this problem, we have designed an optical switch and a beam splitter to control and separate the transmitted light. When replacing traditional sources, the lighting should have similar characteristics, such as intensity distribution and geometric parameters, to those of traditional artificial sources. We have designed, simulated, and optimized an illumination lightpipe with a dot pattern to redistribute the collected sunlight from the natural light illumination system such that it equals the qualities of a traditional lighting system. We also provide an active lighting module that provides lighting from the natural light illumination system or LED auxiliary

  14. Fibre illumination system

    DEFF Research Database (Denmark)

    2012-01-01

    the proximal end of the collection optics into the first end of the input fibre, each collector element having a principal axis for the collection of light defining an optical axis of the collector element. The optical axes of the collector elements are arranged in a radially outward pointing multi......Source: EP2426402A The invention relates to a fibre illumination module and system for the collection and delivery of daylight for illumination purposes. The fibre illumination module comprises a plurality of collector elements, each collector element comprising an input fibre having a first end...... and a second end, and a collection optics, the collection optics being configured to receive light incident on a distal end of the collection optics, to transfer at least partially the incident light to a proximal end of the collection optics, and to couple at least partially the transferred light from...

  15. OLED area illumination source

    Science.gov (United States)

    Foust, Donald Franklin; Duggal, Anil Raj; Shiang, Joseph John; Nealon, William Francis; Bortscheller, Jacob Charles

    2008-03-25

    The present invention relates to an area illumination light source comprising a plurality of individual OLED panels. The individual OLED panels are configured in a physically modular fashion. Each OLED panel comprising a plurality of OLED devices. Each OLED panel comprises a first electrode and a second electrode such that the power being supplied to each individual OLED panel may be varied independently. A power supply unit capable of delivering varying levels of voltage simultaneously to the first and second electrodes of each of the individual OLED panels is also provided. The area illumination light source also comprises a mount within which the OLED panels are arrayed.

  16. Varying Constants

    CERN Document Server

    Damour, Thibault Marie Alban Guillaume

    2003-01-01

    We review some string-inspired theoretical models which incorporate a correlated spacetime variation of coupling constants while remaining naturally compatible both with phenomenological constraints coming from geochemical data (Oklo; Rhenium decay) and with present equivalence principle tests. Barring unnatural fine-tunings of parameters, a variation of the fine-structure constant as large as that recently ``observed'' by Webb et al. in quasar absorption spectra appears to be incompatible with these phenomenological constraints. Independently of any model, it is emphasized that the best experimental probe of varying constants are high-precision tests of the universality of free fall, such as MICROSCOPE and STEP. Recent claims by Bekenstein that fine-structure-constant variability does not imply detectable violations of the equivalence principle are shown to be untenable.

  17. Illumination by Tangent Lines

    CERN Document Server

    Horwitz, Alan

    2011-01-01

    Let f be a differentiable function on the real line, and let P\\inG_{f}^{C}= all points not on the graph of f. We say that the illumination index of P, denoted by I_{f}(P), is k if there are k distinct tangents to the graph of f which pass through P. In section 2 we prove results about the illumination index of f with f" (x)\\geq 0 on \\Re. In particular, suppose that y=L_1(x) and y=L_2(x) are distinct oblique asymptotes of f and let P=(s,t)\\in G_{f}^{C}. If max(L_1(s),L_2(s))

  18. Lighting system with illuminance control

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to an illumination control system comprising a plurality of outdoor luminaries and a motorized service vehicle. Each luminaire comprises a controllable light source producing a light illuminance. The motorized service vehicle comprises a light sensor configured...... to detect the light illuminance generated by the controllable light source at the motorized service vehicle. The motorized service vehicle computes light illuminance data based on the detected light illuminance and transmits these to the outdoor luminaire through a wireless communication link or stores...... the light illuminance data on a data recording device of the motorized service vehicle. The outdoor luminaire receives may use the light illuminance data to set or adjust a light illuminance of the controllable light source....

  19. MATHEMATICAL CONSTANTS.

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, H.P.; Potter, Elinor

    1971-03-01

    This collection of mathematical data consists of two tables of decimal constants arranged according to size rather than function, a third table of integers from 1 to 1000, giving some of their properties, and a fourth table listing some infinite series arranged according to increasing size of the coefficients of the terms. The decimal values of Tables I and II are given to 20 D.

  20. Hemaka's constant

    CERN Document Server

    Sparavigna, Amelia Carolina

    2012-01-01

    As proposed in a previous paper, the decorations of ancient objects can provide some information on the approximate evaluations of constant {\\pi}, the ratio of circumference to diameter. Here we discuss some disks found in the tomb of Hemaka, the chancellor of a king of the First Dynasty of Egypt, about 3000 BC. The discussion is based on measurements of the dimensionless ratio of lengths.

  1. Parallel hierarchical global illumination

    Energy Technology Data Exchange (ETDEWEB)

    Snell, Quinn O. [Iowa State Univ., Ames, IA (United States)

    1997-10-08

    Solving the global illumination problem is equivalent to determining the intensity of every wavelength of light in all directions at every point in a given scene. The complexity of the problem has led researchers to use approximation methods for solving the problem on serial computers. Rather than using an approximation method, such as backward ray tracing or radiosity, the authors have chosen to solve the Rendering Equation by direct simulation of light transport from the light sources. This paper presents an algorithm that solves the Rendering Equation to any desired accuracy, and can be run in parallel on distributed memory or shared memory computer systems with excellent scaling properties. It appears superior in both speed and physical correctness to recent published methods involving bidirectional ray tracing or hybrid treatments of diffuse and specular surfaces. Like progressive radiosity methods, it dynamically refines the geometry decomposition where required, but does so without the excessive storage requirements for ray histories. The algorithm, called Photon, produces a scene which converges to the global illumination solution. This amounts to a huge task for a 1997-vintage serial computer, but using the power of a parallel supercomputer significantly reduces the time required to generate a solution. Currently, Photon can be run on most parallel environments from a shared memory multiprocessor to a parallel supercomputer, as well as on clusters of heterogeneous workstations.

  2. Pulsed laser illumination of photovoltaic cells

    Science.gov (United States)

    Yater, Jane A.; Lowe, Roland A.; Jenkins, Phillip P.; Landis, Geoffrey A.

    1995-01-01

    In future space missions, free electron lasers (FEL) may be used to illuminate photovoltaic receivers to provide remote power. Both the radio-frequency (RF) and induction FEL produce pulsed rather than continuous output. In this work we investigate cell response to pulsed laser light which simulates the RF FEL format. The results indicate that if the pulse repetition is high, cell efficiencies are only slightly reduced compared to constant illumination at the same wavelength. The frequency response of the cells is weak, with both voltage and current outputs essentially dc in nature. Comparison with previous experiments indicates that the RF FEL pulse format yields more efficient photovoltaic conversion than does an induction FEL format.

  3. Improved array illuminators.

    Science.gov (United States)

    Lohmann, A W; Sinzinger, S

    1992-09-10

    The job of an array illuminator is to provide an array of optical gates or smart pixels with photon power or with synchronous clock signals. So far it has been common to take the power from one big laser and distribute it to perhaps a million gates. An obvious alternative is to assign one private small source to each gate. We favor an in-between approach: a few medium-size sources share the job of providing photons. This hybrid approach has several advantages, such as better homogeneity, less coherent noise, and a distributed risk of source failure. We propose several setups and present some experimental results. Our concept calls for an array of incoherent point sources. We simulate such an array experimentally with a single source, which is virtually expanded into a source array by grating diffraction. Ordinarily these virtual sources are mutually coherent, which is undesirable for our aims. We destroy the mutual coherence by moving the grating during the photographic recording of the output array.

  4. Optical tomography with structured illumination.

    Science.gov (United States)

    Lukic, Vladimir; Markel, Vadim A; Schotland, John C

    2009-04-01

    We consider the image reconstruction problem for optical tomography with structured illumination. A fast image reconstruction algorithm is proposed that reduces the required number of measurements of the optical field compared to methods that utilize point-source illumination. The results are illustrated with numerical simulations.

  5. Classification of Global Illumination Algorithms

    OpenAIRE

    Lesev, Hristo

    2010-01-01

    This article describes and classifies various approaches for solving the global illumination problem. The classification aims to show the similarities between different types of algorithms. We introduce the concept of Light Manager, as a central element and mediator between illumination algorithms in a heterogeneous environment of a graphical system. We present results and analysis of the implementation of the described ideas.

  6. Illuminated push-button switch

    Science.gov (United States)

    Iwagiri, T.

    1983-01-01

    An illuminated push-button switch is described. It is characterized by the fact that is consists of a switch group, an operator button opening and closing the switch group, and a light-emitting element which illuminates the face of the operator button.

  7. Matching illumination of solid objects.

    Science.gov (United States)

    Pont, Sylvia C; Koenderink, Jan J

    2007-04-01

    The appearance of objects is determined by their surface reflectance and roughness and by the light field. Conversely, human observers might derive properties of the light field from the appearance of objects. The inverse problem has no unique solution, so perceptual interactions between reflectance, roughness, and lightfield are to be expected. In two separate experiments, we tested whether observers are able to match the illumination of spheres under collimated illumination only (matching of illumination direction) and under more or less diffuse illumination (matching of illumination direction and directedness of the beam). We found that observers are quite able to match collimated illumination directions of two rendered Lambertian spheres. Matching of the collimated beam directions of a Lambertian sphere and that of a real object with arbitrary reflectance and roughness properties resulted in similar results for the azimuthal angle, but in higher variance for the polar angle. Translucent objects and a tennis ball were found to be systematic outliers. If the directedness of the beam was also varied, the direction settings showed larger variance for more diffuse illumination. The directedness settings showed an overall quite large variance and, interestingly, interacted with the polar angle settings. We discuss possible photometrical mechanisms behind these effects.

  8. Efficient color representation for image segmentation under nonwhite illumination

    Science.gov (United States)

    Park, Jae Byung

    2003-10-01

    Color image segmentation algorithms often consider object color to be a constant property of an object. If the light source dominantly exhibits a particular color, however, it becomes necessary to consider the color variation induced by the colored illuminant. This paper presents a new approach to segmenting color images that are photographed under non-white illumination conditions. It also addresses how to estimate the color of illuminant in terms of the standard RGB color values rather than the spectrum of the illuminant. With respect to the illumination axis that goes through the origin and the centroid of illuminant color clusters (prior given by the estimation process), the RGB color space is transformed into our new color coordinate system. Our new color scheme shares the intuitiveness of the HSI (HSL or HSV) space that comes from the conical (double-conical or cylindrical) structure of hue and saturation aligned with the intensity variation at its center. It has been developed by locating the ordinary RGB cube in such a way that the illumination axis aligns with the vertical axis (Z-axis) of a larger Cartesian (XYZ) space. The work in this paper uses the dichromatic reflection model [1] to interpret the physics about light and optical effects in color images. The linearity proposed in the dichromatic reflection model is essential and is well preserved in the RGB color space. By proposing a straightforward color model transduction, we suggest dimensionality reduction and provide an efficient way to analyze color images of dielectric objects under non-white illumination conditions. The feasibility of the proposed color representation has been demonstrated by our experiment that is twofold: 1) Segmentation result from a multi-modal histogram-based thresholding technique and 2) Color constancy result from discounting illumination effect further by color balancing.

  9. Virtual illumination grid for correction of uncontrolled illumination in facial images

    NARCIS (Netherlands)

    Boom, B.J.; Spreeuwers, L.J.; Veldhuis, R.N.J.

    2010-01-01

    Face recognition under uncontrolled illumination conditions is still considered an unsolved problem. In order to correct for these illumination conditions, we propose a virtual illumination grid (VIG) approach to model the unknown illumination conditions. Furthermore, we use coupled subspace models

  10. Laser sources for object illumination

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, G.F. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    The considerations which formulate the specifications for a laser illuminator are explained, using the example of an underwater object. Depending on the parameters which define the scenario, widely varying laser requirements result.

  11. Face Recognition in Various Illuminations

    Directory of Open Access Journals (Sweden)

    Saurabh D. Parmar,

    2014-05-01

    Full Text Available Face Recognition (FR under various illuminations is very challenging. Normalization technique is useful for removing the dimness and shadow from the facial image which reduces the effect of illumination variations still retaining the necessary information of the face. The robust local feature extractor which is the gray-scale invariant texture called Local Binary Pattern (LBP is helpful for feature extraction. K-Nearest Neighbor classifier is utilized for the purpose of classification and to match the face images from the database. Experimental results were based on Yale-B database with three different sub categories. The proposed method has been tested to robust face recognition in various illumination conditions. Extensive experiment shows that the proposed system can achieve very encouraging performance in various illumination environments.

  12. An Army Illumination Model (AAIM)

    Science.gov (United States)

    2008-11-01

    6639000 India Chennai 13.060 80.250 24 Population Country City Latitude Longitude 11680000 India Delhi 28.667 77.233 6833000 India Hyderabad 17.385...providing illumination levels for cities , the model now includes values for lunar illumination under clear or (partially) cloudy skies at ground level...function of population and distance (>10 km) from city center under clear and overcast conditions. A technical overview of the model, along with

  13. Image plane sweep volume illumination.

    Science.gov (United States)

    Sundén, Erik; Ynnerman, Anders; Ropinski, Timo

    2011-12-01

    In recent years, many volumetric illumination models have been proposed, which have the potential to simulate advanced lighting effects and thus support improved image comprehension. Although volume ray-casting is widely accepted as the volume rendering technique which achieves the highest image quality, so far no volumetric illumination algorithm has been designed to be directly incorporated into the ray-casting process. In this paper we propose image plane sweep volume illumination (IPSVI), which allows the integration of advanced illumination effects into a GPU-based volume ray-caster by exploiting the plane sweep paradigm. Thus, we are able to reduce the problem complexity and achieve interactive frame rates, while supporting scattering as well as shadowing. Since all illumination computations are performed directly within a single rendering pass, IPSVI does not require any preprocessing nor does it need to store intermediate results within an illumination volume. It therefore has a significantly lower memory footprint than other techniques. This makes IPSVI directly applicable to large data sets. Furthermore, the integration into a GPU-based ray-caster allows for high image quality as well as improved rendering performance by exploiting early ray termination. This paper discusses the theory behind IPSVI, describes its implementation, demonstrates its visual results and provides performance measurements.

  14. Characterisation of pulsed Carbon fiber illuminators for FIR instrument calibration

    CERN Document Server

    Henrot-Versillé, S; Couchot, F

    2007-01-01

    We manufactured pulsed illuminators emitting in the far infrared for the Planck-HFI bolometric instrument ground calibrations. Specific measurements have been conducted on these light sources, based on Carbon fibers, to understand and predict their properties. We present a modelisation of the temperature dependence of the thermal conductivity and the calorific capacitance of the fibers. A comparison between simulations and bolometer data is given, that shows the coherence of our model. Their small time constants, their stability and their emission spectrum pointing in the submm range make these illuminators a very usefull tool for calibrating FIR instruments.

  15. Novel illumination system for EUVL

    Science.gov (United States)

    Komatsuda, Hideki

    2000-07-01

    A concept for a novel arc-field, illumination projection system, particularly for EUVL applications, is presented. This system consists of a light source, a collector, a fly-eye, and a condenser. The fly-eye has two reflectors. One of them is constructed with using arc-shaped, concave mirror elements, the other using many rectangular, concave mirror elements. Both elements are arranged closely side by side. All of the arc-shaped mirrors have a corresponding rectangular mirror on a one-to-one basis. Each rectangular mirror projects its corresponding arc-shaped mirror's images onto an arc projection field on the mask. As a consequence, all of incident rays on fly-eye reflector constructed by arc-shape mirror elements are gathered in the arc projection field. Currently, the main type of illumination system for EUVL is based on so-called 'Koehler-critical illumination,' which is not necessarily proper for a scanner system. Then this system adopts Koehler illumination. It is necessary for scanner illumination systems to have means for minute adjustments of its properties (e.g. irradiance distribution). Such adjustments means are presented.

  16. Beam splitting on weak illumination.

    Science.gov (United States)

    Snyder, A W; Buryak, A V; Mitchell, D J

    1998-01-01

    We demonstrate, in both two and three dimensions, how a self-guided beam in a non-Kerr medium is split into two beams on weak illumination. We also provide an elegant physical explanation that predicts the universal character of the observed phenomenon. Possible applications of our findings to guiding light with light are also discussed.

  17. Joint reconstruction strategy for structured illumination microscopy with unknown illuminations

    CERN Document Server

    Labouesse, Simon; Idier, Jérôme; Bourguignon, Sébastien; Negash, Awoke; Liu, Penghuan; Sentenac, Anne

    2016-01-01

    The blind structured illumination microscopy (SIM) strategy proposed in (Mudry et al., 1992) is drastically revisited in this paper, unveiling the mechanism that drives the super-resolution in the method. A much improved numerical implementation is also provided for the reconstruction problem under the image positivity constraint. This algorithm rests on a new preconditioned proximal iteration faster than existing solutions, paving the way to 3D and real-time 2D reconstruction.

  18. Laser illuminated flat panel display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-12-31

    A 10 inch laser illuminated flat panel Planar Optic Display (POD) screen has been constructed and tested. This POD screen technology is an entirely new concept in display technology. Although the initial display is flat and made of glass, this technology lends itself to applications where a plastic display might be wrapped around the viewer. The display screen is comprised of hundreds of planar optical waveguides where each glass waveguide represents a vertical line of resolution. A black cladding layer, having a lower index of refraction, is placed between each waveguide layer. Since the cladding makes the screen surface black, the contrast is high. The prototype display is 9 inches wide by 5 inches high and approximately I inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  19. Illumination box and camera system

    Science.gov (United States)

    Haas, Jeffrey S.; Kelly, Fredrick R.; Bushman, John F.; Wiefel, Michael H.; Jensen, Wayne A.; Klunder, Gregory L.

    2002-01-01

    A hand portable, field-deployable thin-layer chromatography (TLC) unit and a hand portable, battery-operated unit for development, illumination, and data acquisition of the TLC plates contain many miniaturized features that permit a large number of samples to be processed efficiently. The TLC unit includes a solvent tank, a holder for TLC plates, and a variety of tool chambers for storing TLC plates, solvent, and pipettes. After processing in the TLC unit, a TLC plate is positioned in a collapsible illumination box, where the box and a CCD camera are optically aligned for optimal pixel resolution of the CCD images of the TLC plate. The TLC system includes an improved development chamber for chemical development of TLC plates that prevents solvent overflow.

  20. Experimental realization of quantum illumination.

    Science.gov (United States)

    Lopaeva, E D; Ruo Berchera, I; Degiovanni, I P; Olivares, S; Brida, G; Genovese, M

    2013-04-12

    We present the first experimental realization of the quantum illumination protocol proposed by Lloyd [Science 321, 1463 (2008)] and S. Tan et al. [Phys. Rev. Lett. 101, 253601 (2008)], achieved in a simple feasible experimental scheme based on photon-number correlations. A main achievement of our result is the demonstration of a strong robustness of the quantum protocol to noise and losses that challenges some widespread wisdom about quantum technologies.

  1. 29 CFR 1918.92 - Illumination.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Illumination. 1918.92 Section 1918.92 Labor Regulations...) SAFETY AND HEALTH REGULATIONS FOR LONGSHORING General Working Conditions. § 1918.92 Illumination. (a... operations, illumination for cargo transfer operations shall be of a minimum light intensity of five...

  2. 29 CFR 1926.26 - Illumination.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Illumination. 1926.26 Section 1926.26 Labor Regulations... Illumination. Construction areas, aisles, stairs, ramps, runways, corridors, offices, shops, and storage areas where work is in progress shall be lighted with either natural or artificial illumination. The...

  3. 29 CFR 1915.92 - Illumination.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Illumination. 1915.92 Section 1915.92 Labor Regulations... Illumination. The provisions of this section shall apply to ship repairing, shipbuilding and shipbreaking. (a... sources outside the vessel is the only means of illumination, portable emergency lighting equipment...

  4. 30 CFR 77.207 - Illumination.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Illumination. 77.207 Section 77.207 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY... Installations § 77.207 Illumination. Illumination sufficient to provide safe working conditions shall...

  5. 49 CFR 230.86 - Required illumination.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Required illumination. 230.86 Section 230.86... Tenders Cabs, Warning Signals, Sanders and Lights § 230.86 Required illumination. (a) General provisions... provides illumination sufficient for a steam locomotive engineer in the cab to see, in a clear...

  6. 29 CFR 1917.123 - Illumination. 9

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Illumination. 9 1917.123 Section 1917.123 Labor Regulations...) MARINE TERMINALS Terminal Facilities § 1917.123 Illumination. 9 9 The United States Coast Guard, at 33 CFR 126.15(1) and (n), and 33 CFR 154.570 sets out requirements for illumination at...

  7. Digital Illumination for Augmented Studios

    Directory of Open Access Journals (Sweden)

    Stefanie Zollmann

    2006-12-01

    Full Text Available Virtual studio technology plays an important role for modern television productions. Blue-screen matting is a common technique for integrating real actors or moderators into computer generated sceneries. Augmented reality offers the possibility to mix real and virtual in a more general context. This article proposes a new technological approach for combining real studio content with computer-generated information. Digital light projection allows a controlled spatial, temporal, chrominance and luminance modulation of illumination opening new possibilities for TV studios.

  8. Robust estimation of albedo for illumination-invariant matching and shape recovery.

    Science.gov (United States)

    Biswas, Soma; Aggarwal, Gaurav; Chellappa, Rama

    2009-05-01

    We present a nonstationary stochastic filtering framework for the task of albedo estimation from a single image. There are several approaches in the literature for albedo estimation, but few include the errors in estimates of surface normals and light source direction to improve the albedo estimate. The proposed approach effectively utilizes the error statistics of surface normals and illumination direction for robust estimation of albedo, for images illuminated by single and multiple light sources. The albedo estimate obtained is subsequently used to generate albedo-free normalized images for recovering the shape of an object. Traditional Shape-from-Shading (SFS) approaches often assume constant/piecewise constant albedo and known light source direction to recover the underlying shape. Using the estimated albedo, the general problem of estimating the shape of an object with varying albedo map and unknown illumination source is reduced to one that can be handled by traditional SFS approaches. Experimental results are provided to show the effectiveness of the approach and its application to illumination-invariant matching and shape recovery. The estimated albedo maps are compared with the ground truth. The maps are used as illumination-invariant signatures for the task of face recognition across illumination variations. The recognition results obtained compare well with the current state-of-the-art approaches. Impressive shape recovery results are obtained using images downloaded from the Web with little control over imaging conditions. The recovered shapes are also used to synthesize novel views under novel illumination conditions.

  9. Ion exchange equilibrium constants

    CERN Document Server

    Marcus, Y

    2013-01-01

    Ion Exchange Equilibrium Constants focuses on the test-compilation of equilibrium constants for ion exchange reactions. The book first underscores the scope of the compilation, equilibrium constants, symbols used, and arrangement of the table. The manuscript then presents the table of equilibrium constants, including polystyrene sulfonate cation exchanger, polyacrylate cation exchanger, polymethacrylate cation exchanger, polysterene phosphate cation exchanger, and zirconium phosphate cation exchanger. The text highlights zirconium oxide anion exchanger, zeolite type 13Y cation exchanger, and

  10. Segmentation and estimation of spatially varying illumination.

    Science.gov (United States)

    Lin Gu; Huynh, Cong Phuoc; Robles-Kelly, Antonio

    2014-08-01

    In this paper, we present an unsupervised method for segmenting the illuminant regions and estimating the illumination power spectrum from a single image of a scene lit by multiple light sources. Here, illuminant region segmentation is cast as a probabilistic clustering problem in the image spectral radiance space. We formulate the problem in an optimization setting, which aims to maximize the likelihood of the image radiance with respect to a mixture model while enforcing a spatial smoothness constraint on the illuminant spectrum. We initialize the sample pixel set under each illuminant via a projection of the image radiance spectra onto a low-dimensional subspace spanned by a randomly chosen subset of spectra. Subsequently, we optimize the objective function in a coordinate-ascent manner by updating the weights of the mixture components, sample pixel set under each illuminant, and illuminant posterior probabilities. We then estimate the illuminant power spectrum per pixel making use of these posterior probabilities. We compare our method with a number of alternatives for the tasks of illumination region segmentation, illumination color estimation, and color correction. Our experiments show the effectiveness of our method as applied to one hyperspectral and three trichromatic image data sets.

  11. Free-form illumination optics

    Science.gov (United States)

    Mohedano, Rubén; Chaves, Julio; Hernández, Maikel

    2016-04-01

    In many illumination problems, the beam pattern needed and/or some geometrical constraints lead to very asymmetric design conditions. These asymmetries have been solved in the past by means of arrangements of rotationally symmetric or linear lamps aimed in different directions whose patterns overlap to provide the asymmetric prescriptions or by splitting one single lamp into several sections, each one providing a part of the pattern. The development of new design methods yielding smooth continuous free-form optical surfaces to solve these challenging design problems, combined with the proper CAD modeling tools plus the development of multiple axes diamond turn machines, give birth to a new generation of optics. These are able to offer the performance and other advanced features, such as efficiency, compactness, or aesthetical advantages, and can be manufactured at low cost by injection molding. This paper presents two examples of devices with free-form optical surfaces, a camera flash, and a car headlamp.

  12. Background illumination and automated perimetry.

    Science.gov (United States)

    Klewin, K M; Radius, R L

    1986-03-01

    Visual field function in the right and left eyes of 31 normal volunteers was evaluated with an automated projection perimeter (OCTOPUS). Serial visual field evaluations were repeated in these same eyes with neutral filters of increasing optical density. We compared the results of threshold determinations with the different neutral filters in place before the examined eye. Significant reduction in threshold sensitivity at several test spots throughout the central 30 degrees visual field was seen with neutral density filters of 0.5 log units or greater. The low level of background illumination of the OCTOPUS perimeter (4.0 apostilbs) may allow relatively minor reduction in light transmission by the ocular media to produce significant changes in the recorded level of threshold sensitivity during visual field evaluation.

  13. Illuminating Electron Microscopy of Photocatalysts

    DEFF Research Database (Denmark)

    Cavalca, Filippo

    rearrangement of the illuminated photocatalysts as well as localized charging effects and variations. We aim to investigate the reaction to gas and light exposure at the nanoscale. References [1] Herrmann, J. M., Top. Catal. 2005, 34, (1-4), 49-65. [2] Tsujimoto, M., S. Moriguchi, et al., J. Electron. Microsc......, composition and operation of photocatalysts and to provide information on the compounds inner arrangement and a fundamental contribution for their further optimization [2]. We want to construct a novel specimen holder capable of shining light onto samples inside the TEM allowing real time in situ experiments....... The holder is implemented with a laser diode and an optical system that guides the light onto the sample surface with maximum power transmission. The source can be changed and tuned according to the needs, in principle spanning the whole visible and UV light spectrum. It is possible to use the device inside...

  14. Optimizing indoor illumination quality and energy efficiency using a spectrally tunable lighting system to augment natural daylight.

    Science.gov (United States)

    Hertog, W; Llenas, A; Carreras, J

    2015-11-30

    This article demonstrates the benefits of complementing a daylight-lit environment with a spectrally tunable illumination system. The spectral components of daylight present in the room are measured by a low-cost miniature spectrophotometer and processed through a number of optimization algorithms, carefully trading color fidelity for energy efficiency. Spectrally-tunable luminaires provide only those wavelengths that ensure that either the final illumination spectrum inside the room is kept constant or carefully follows the dynamic spectral pattern of natural daylight. Analyzing the measured data proves that such a hybrid illumination system brings both unprecendented illumination quality and significant energy savings.

  15. Cosmological Constant, Fine Structure Constant and Beyond

    CERN Document Server

    Wei, Hao; Li, Hong-Yu; Xue, Dong-Ze

    2016-01-01

    In this work, we consider the cosmological constant model $\\Lambda\\propto\\alpha^{-6}$, which is well motivated from three independent approaches. As is well known, the evidence of varying fine structure constant $\\alpha$ was found in 1998. If $\\Lambda\\propto\\alpha^{-6}$ is right, it means that the cosmological constant $\\Lambda$ should be also varying. In this work, we try to develop a suitable framework to model this varying cosmological constant $\\Lambda\\propto\\alpha^{-6}$, in which we view it from an interacting vacuum energy perspective. We propose two types of models to describe the evolutions of $\\Lambda$ and $\\alpha$. Then, we consider the observational constraints on these models, by using the 293 $\\Delta\\alpha/\\alpha$ data from the absorption systems in the spectra of distant quasars, and the data of type Ia supernovae (SNIa), cosmic microwave background (CMB), baryon acoustic oscillation (BAO). We find that the model parameters can be tightly constrained to the narrow ranges of ${\\cal O}(10^{-5})$ t...

  16. Illumination discrimination in real and simulated scenes

    Science.gov (United States)

    Radonjić, Ana; Pearce, Bradley; Aston, Stacey; Krieger, Avery; Dubin, Hilary; Cottaris, Nicolas P.; Brainard, David H.; Hurlbert, Anya C.

    2016-01-01

    Characterizing humans' ability to discriminate changes in illumination provides information about the visual system's representation of the distal stimulus. We have previously shown that humans are able to discriminate illumination changes and that sensitivity to such changes depends on their chromatic direction. Probing illumination discrimination further would be facilitated by the use of computer-graphics simulations, which would, in practice, enable a wider range of stimulus manipulations. There is no a priori guarantee, however, that results obtained with simulated scenes generalize to real illuminated scenes. To investigate this question, we measured illumination discrimination in real and simulated scenes that were well-matched in mean chromaticity and scene geometry. Illumination discrimination thresholds were essentially identical for the two stimulus types. As in our previous work, these thresholds varied with illumination change direction. We exploited the flexibility offered by the use of graphics simulations to investigate whether the differences across direction are preserved when the surfaces in the scene are varied. We show that varying the scene's surface ensemble in a manner that also changes mean scene chromaticity modulates the relative sensitivity to illumination changes along different chromatic directions. Thus, any characterization of sensitivity to changes in illumination must be defined relative to the set of surfaces in the scene.

  17. Improved Interference configuration for structured illumination microscopy

    Science.gov (United States)

    Chen, Houkai; Wei, Shibiao; Wu, Xiaojing; Yang, Yong; Zhang, Yuquan; Du, Luping; Liu, Jun; Zhu, Siwei; Yuan, Xiaocong

    2017-02-01

    We present an improved structured illumination configuration for structured illumination microscopy (SIM) based on spatial light modulator. Precise phase shifts and rotation of illumination fringes can be dynamically controlled using a spatial light modulator. The method is different from the conventional illumination configuration that are based on interference of ±1 diffractive order light. The experimental setup requires less optical elements making it compact, reliable, and suitable for integration. The method has been applied in the standing-wave total internal reflection fluorescent microscopy. High lateral resolution of sub-100 nm was achieved in single directional resolution enhancement experiments.

  18. Anisotropic Density Estimation in Global Illumination

    DEFF Research Database (Denmark)

    Schjøth, Lars

    2009-01-01

    Density estimation employed in multi-pass global illumination algorithms gives cause to a trade-off problem between bias and noise. The problem is seen most evident as blurring of strong illumination features. This thesis addresses the problem, presenting four methods that reduce both noise...... and bias in estimates. Good results are obtained by the use of anisotropic filtering. Two methods handles the most common cases; filtering illumination reflected from object surfaces. One methods extends filtering to the temporal domain and one performs filtering on illumination from participating media...

  19. Circadian rhythms in rat pineal melatonin synthesis Under constant darkness Conditions%持续黑暗状态下对大鼠松果体细胞分泌松果体素的昼夜节律研究

    Institute of Scientific and Technical Information of China (English)

    刘雅静; 陆仲敏; 朱红艳; 谭忠林; 周江宁

    2011-01-01

    为研究体外培养的大鼠松果体细胞分泌的松果体素是否具有内在节律,收集体外培养的大鼠松果体细胞在白天6:00,8:00,10:00,12:00,15:00,和夜晚18:00,20:00,22:00,1:00,4:00各个时间点的培养上清,并用放射免疫方法(RIA)检测各个时间点松果体细胞培养上清中的松果体素水平.CCF(complex cosine function)统计分析结果表明,在持续黑暗的环境下,体外培养的大鼠松果体细胞分泌的松果体素在培养3,6,9天后仍然表现出内在节律.然而,这种内在节律在培养12天后消失.上述结果提示体外培养的大鼠松果体细胞可以作为一个有用的体外模型来分析节律系统的生理基础.%To investigate whether rat pineal cell is capable of generating a circadian oscillation in melatonin release, the cultured pineal cell in culture medium was collected at 6 : 00, 8 : 00, 10 :00, 12 : 00 and 15 : 00 during the day, and at 18 : 00, 20 ." 00, 22 : 00, 1 : 00 and 4 : 00 at night respectively. The melatonin level in culture medium was measured by a direct radioimmunoassay.The complex cosine functions (CCF) statistical analysis indicates that the rat pineal cell melatonin synthesis shows an intrinsic rhythm at 3, 6, 9 day culture under constant dark conditions.However, the intrinsic rhythm disappears at 12 day culture. This result suggests that the rat individual pineal cells can function as a circadian oscillator in vitro.

  20. Extinction-Optimized Volume Illumination.

    Science.gov (United States)

    Ament, Marco; Zirr, Tobias; Dachsbacher, Carsten

    2016-05-16

    We present a novel method to optimize the attenuation of light for the single scattering model in direct volume rendering. A common problem of single scattering is the high dynamic range between lit and shadowed regions due to the exponential attenuation of light along a ray. Moreover, light is often attenuated too strong between a sample point and the camera, hampering the visibility of important features. Our algorithm employs an importance function to selectively illuminate important structures and make them visible from the camera. With the importance function, more light can be transmitted to the features of interest, while contextual structures cast shadows which provide visual cues for perception of depth. At the same time, more scattered light is transmitted from the sample point to the camera to improve the primary visibility of important features. We formulate a minimization problem that automatically determines the extinction along a view or shadow ray to obtain a good balance between sufficient transmittance and attenuation. In contrast to previous approaches, we do not require a computationally expensive solution of a global optimization, but instead provide a closed-form solution for each sampled extinction value along a view or shadow ray and thus achieve interactive performance.

  1. Secure communication via quantum illumination

    Science.gov (United States)

    Shapiro, Jeffrey H.; Zhang, Zheshen; Wong, Franco N. C.

    2014-10-01

    In the quantum illumination protocol for secure communication, Alice prepares entangled signal and idler beams via spontaneous parametric downconversion. She sends the signal beam to Bob, while retaining the idler. Bob imposes message modulation on the beam he receives from Alice, amplifies it, and sends it back to her. Alice then decodes Bob's information by making a joint quantum measurement on the light she has retained and the light she has received from him. The basic performance analysis for this protocol—which demonstrates its immunity to passive eavesdropping, in which Eve can only listen to Alice and Bob's transmissions—is reviewed, along with the results of its first proof-of-principle experiment. Further analysis is then presented, showing that secure data rates in excess of 1 Gbps may be possible over 20-km-long fiber links with technology that is available or under development. Finally, an initial scheme for thwarting active eavesdropping, in which Eve injects her own light into Bob's terminal, is proposed and analyzed.

  2. Illumination correction in psoriasis lesions images

    DEFF Research Database (Denmark)

    Maletti, Gabriela Mariel; Ersbøll, Bjarne Kjær

    2003-01-01

    An approach to automatically correct illumination problems in dermatological images is presented. The illumination function is estimated after combining the thematic map indicating skin-produced by an automated classification scheme- with the dermatological image data. The user is only required t...

  3. Translating Rimbaud's "Illuminations": Games with Words

    Science.gov (United States)

    Slote, Daniel

    1978-01-01

    Rimbaud's "Illuminations," one vast word-game, is used as an example of one of the most interesting challenges in translation--the rendering of plays on words. The process is discussed and illustrated by the analysis of numerous segments from "Illuminations." It is concluded that a satisfactory translation is almost impossible.…

  4. Daylight illuminance control with fuzzy logic

    Energy Technology Data Exchange (ETDEWEB)

    Trobec Lah, Mateja; Peternelj, Joze; Krainer, Ales [University of Ljubljana, Faculty of Civil and Geodetic Engineering, Jamova cesta 2, 1000 Ljubljana (Slovenia); Zupancic, Borut [University of Ljubljana, Faculty of Electrical Engineering, Trzaska 25, 1000 Ljubljana (Slovenia)

    2006-03-15

    The purpose is to take full advantage of daylight for inside illumination. The inside illuminance and luminous efficacy of the available solar radiation were analyzed. The paper deals with the controlled dynamic illuminance response of built environment in real-time conditions. The aim is controlled functioning of the roller blind as a regulation device to assure the desired inside illuminance with smooth roller blind moving. Automatic illuminance control based on fuzzy logic is realized on a test chamber with an opening on the south side. The development and design of the fuzzy controller for the corresponding positioning of the roller blind with the available solar radiation as external disturbance is the subject of this paper. (author)

  5. Isotropic-planar illumination for PIV experiments

    Science.gov (United States)

    Atkins, Michael D.; Kim, Tongbeum

    2015-03-01

    A new method for laser illumination in particle image velocimetry (PIV) has been introduced: internal "isotropic-planar" illumination that provides laser light to regions of the flow field that were previously cast into shadow using the conventional external (laser light sheet) illumination method. To demonstrate the effectiveness of the isotropic-planar illumination method, a comparison of the measured velocity field around five side-by-side circular cylinders that are immersed in uniform flow is made against the conventional external illumination method. The new method is effective at eliminating the shadow region, allowing the velocity field of the upstream, gap and downstream regions around the five side-by-side circular cylinders to be measured simultaneously. These PIV measurements provide new insight into the behavior of the gap flow that passes between the cylinders.

  6. Generalized Pickands constants

    NARCIS (Netherlands)

    Debicki, K.G.

    2001-01-01

    Pickands constants play an important role in the exact asymptotic of extreme values for Gaussian stochastic processes. By the {it generalized Pickands constant ${cal H_{eta$ we mean the limit begin{eqnarray* {cal H_{eta= lim_{T to inftyfrac{ {cal H_{eta(T){T, end{eqnarray* where ${cal H_{eta(T)= Exp

  7. Light pollution: the possible consequences of excessive illumination on retina.

    Science.gov (United States)

    Contín, M A; Benedetto, M M; Quinteros-Quintana, M L; Guido, M E

    2016-02-01

    Light is the visible part of the electromagnetic radiation within a range of 380-780 nm; (400-700 on primates retina). In vertebrates, the retina is adapted to capturing light photons and transmitting this information to other structures in the central nervous system. In mammals, light acts directly on the retina to fulfill two important roles: (1) the visual function through rod and cone photoreceptor cells and (2) non-image forming tasks, such as the synchronization of circadian rhythms to a 24 h solar cycle, pineal melatonin suppression and pupil light reflexes. However, the excess of illumination may cause retinal degeneration or accelerate genetic retinal diseases. In the last century human society has increased its exposure to artificial illumination, producing changes in the Light/Dark cycle, as well as in light wavelengths and intensities. Although, the consequences of unnatural illumination or light pollution have been underestimated by modern society in its way of life, light pollution may have a strong impact on people's health. The effects of artificial light sources could have direct consequences on retinal health. Constant exposure to different wavelengths and intensities of light promoted by light pollution may produce retinal degeneration as a consequence of photoreceptor or retinal pigment epithelium cells death. In this review we summarize the different mechanisms of retinal damage related to the light exposure, which generates light pollution.

  8. Joint Effects of Illumination Geometry and Object Shape in the Perception of Surface Reflectance

    Directory of Open Access Journals (Sweden)

    Maria Olkkonen

    2011-12-01

    Full Text Available Surface properties provide useful information for identifying objects and interacting with them. Effective utilization of this information, however, requires that the perception of object surface properties be relatively constant across changes in illumination and changes in object shape. Such constancy has been studied separately for changes in these factors. Here we ask whether the separate study of the illumination and shape effects is sufficient, by testing whether joint effects of illumination and shape changes can be predicted from the individual effects in a straightforward manner. We found large interactions between illumination and object shape in their effects on perceived glossiness. In addition, analysis of luminance histogram statistics could not account for the interactions.

  9. Daylight calculations using constant luminance curves

    Energy Technology Data Exchange (ETDEWEB)

    Betman, E. [CRICYT, Mendoza (Argentina). Laboratorio de Ambiente Humano y Vivienda

    2005-02-01

    This paper presents a simple method to manually estimate daylight availability and to make daylight calculations using constant luminance curves calculated with local illuminance and irradiance data and the all-weather model for sky luminance distribution developed in the Atmospheric Science Research Center of the University of New York (ARSC) by Richard Perez et al. Work with constant luminance curves has the advantage that daylight calculations include the problem's directionality and preserve the information of the luminous climate of the place. This permits accurate knowledge of the resource and a strong basis to establish conclusions concerning topics related to the energy efficiency and comfort in buildings. The characteristics of the proposed method are compared with the method that uses the daylight factor. (author)

  10. Long-range laser-illuminated imaging

    Science.gov (United States)

    Dayton, David C.; Browne, Stephen L.; Sandven, Steven C.; Gonglewski, John D.; Gallegos, Joe; Shilko, Michael L., Sr.

    2000-11-01

    We demonstrate the utility of laser illuminated imaging for clandestine night time surveillance from a simulated airborne platform at standoff ranges in excess 20 km. In order to reduce the necessary laser per pulse energy required for illumination at such long ranges, and to mitigate atmospheric turbulence effects on image resolution, we have investigated a unique multi-frame post-processing technique. It is shown that in the presence of atmospheric turbulence and coherent speckle effects, this approach can produce superior results to conventional scene flood illumination.

  11. Image Based Rendering under Varying Illumination

    Institute of Scientific and Technical Information of China (English)

    Wang Chengfeng (王城峰); Hu Zhanyi

    2003-01-01

    A new approach for photorealistic rendering of a class of objects at arbitrary illumination is presented. The approach of the authors relies entirely on image based rendering techniques. A scheme is utilized for re-illumination of objects based on linear combination of low dimensional image representations. The minimum rendering condition of technique of the authors is three sample images under varying illumination of a reference object and a single input image of an interested object. Important properties of this approach are its simplicity, robustness and speediness. Experimental results validate the proposed rendering approach.

  12. Saturated pattern-illuminated Fourier ptychography microscopy

    Science.gov (United States)

    Fang, Yue; Chen, Youhua; Kuang, Cuifang; Xiu, Peng; Liu, Qiulan; Ge, Baoliang; Liu, Xu

    2017-01-01

    We report a series of simulation studies which extends pattern-illuminated Fourier ptychography microscopy by integrating with the nonlinearity arising from saturation of the fluorophore excited state for super-resolution fluorescence imaging. This extended technique, termed Saturated pattern-illuminated Fourier ptychography (SpiFP) microscopy, could achieve a resolution four times that of wide field when the illuminating light intensity approaches the saturation threshold in simulations. Increasing light intensity leads to further resolution enhancement. In order to demonstrate the performance of SpiFP, we make a comparison between SpiFP and saturated structure illumination microscopy in simulations, and prove that the SpiFP exhibits superior robustness to noise, aberration correcting ability, and pattern’s flexibility. Introducing the saturation of the fluorescent emission brings in notable improvements in imaging performance, implying its potential in nanoscale-sized biological observations by wide-field microscopy.

  13. AN ILLUMINATION INVARIANT TEXTURE BASED FACE RECOGNITION

    Directory of Open Access Journals (Sweden)

    K. Meena

    2013-11-01

    Full Text Available Automatic face recognition remains an interesting but challenging computer vision open problem. Poor illumination is considered as one of the major issue, since illumination changes cause large variation in the facial features. To resolve this, illumination normalization preprocessing techniques are employed in this paper to enhance the face recognition rate. The methods such as Histogram Equalization (HE, Gamma Intensity Correction (GIC, Normalization chain and Modified Homomorphic Filtering (MHF are used for preprocessing. Owing to great success, the texture features are commonly used for face recognition. But these features are severely affected by lighting changes. Hence texture based models Local Binary Pattern (LBP, Local Derivative Pattern (LDP, Local Texture Pattern (LTP and Local Tetra Patterns (LTrPs are experimented under different lighting conditions. In this paper, illumination invariant face recognition technique is developed based on the fusion of illumination preprocessing with local texture descriptors. The performance has been evaluated using YALE B and CMU-PIE databases containing more than 1500 images. The results demonstrate that MHF based normalization gives significant improvement in recognition rate for the face images with large illumination conditions.

  14. Variation of Fundamental Constants

    Science.gov (United States)

    Flambaum, V. V.

    2006-11-01

    Theories unifying gravity with other interactions suggest temporal and spatial variation of the fundamental ``constants'' in expanding Universe. The spatial variation can explain a fine tuning of the fundamental constants which allows humans (and any life) to appear. We appeared in the area of the Universe where the values of the fundamental constants are consistent with our existence. We present a review of recent works devoted to the variation of the fine structure constant α, strong interaction and fundamental masses. There are some hints for the variation in quasar absorption spectra. Big Bang nucleosynthesis, and Oklo natural nuclear reactor data. A very promising method to search for the variation of the fundamental constants consists in comparison of different atomic clocks. Huge enhancement of the variation effects happens in transition between accidentally degenerate atomic and molecular energy levels. A new idea is to build a ``nuclear'' clock based on the ultraviolet transition between very low excited state and ground state in Thorium nucleus. This may allow to improve sensitivity to the variation up to 10 orders of magnitude! Huge enhancement of the variation effects is also possible in cold atomic and molecular collisions near Feshbach resonance.

  15. Elastic constants of calcite

    Science.gov (United States)

    Peselnick, L.; Robie, R.A.

    1962-01-01

    The recent measurements of the elastic constants of calcite by Reddy and Subrahmanyam (1960) disagree with the values obtained independently by Voigt (1910) and Bhimasenachar (1945). The present authors, using an ultrasonic pulse technique at 3 Mc and 25??C, determined the elastic constants of calcite using the exact equations governing the wave velocities in the single crystal. The results are C11=13.7, C33=8.11, C44=3.50, C12=4.82, C13=5.68, and C14=-2.00, in units of 1011 dyncm2. Independent checks of several of the elastic constants were made employing other directions and polarizations of the wave velocities. With the exception of C13, these values substantially agree with the data of Voigt and Bhimasenachar. ?? 1962 The American Institute of Physics.

  16. Algorithm for structure constants

    CERN Document Server

    Paiva, F M

    2011-01-01

    In a $n$-dimensional Lie algebra, random numerical values are assigned by computer to $n(n-1)$ especially selected structure constants. An algorithm is then created, which calculates without ambiguity the remaining constants, obeying the Jacobi conditions. Differently from others, this algorithm is suitable even for poor personal computer. ------------- En $n$-dimensia algebro de Lie, hazardaj numeraj valoroj estas asignitaj per komputilo al $n(n-1)$ speciale elektitaj konstantoj de strukturo. Tiam algoritmo estas kreita, kalkulante senambigue la ceterajn konstantojn, obeante kondicxojn de Jacobi. Malsimile al aliaj algoritmoj, tiu cxi tauxgas ecx por malpotenca komputilo.

  17. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  18. The aliquot constant

    CERN Document Server

    Bosma, Wieb

    2009-01-01

    The average value of log s(n)/n taken over the first N even integers is shown to converge to a constant lambda when N tends to infinity; moreover, the value of this constant is approximated and proven to be less than 0. Here s(n) sums the divisors of n less than n. Thus the geometric mean of s(n)/n, the growth factor of the function s, in the long run tends to be less than 1. This could be interpreted as probabilistic evidence that aliquot sequences tend to remain bounded.

  19. Illumination compensation in ground based hyperspectral imaging

    Science.gov (United States)

    Wendel, Alexander; Underwood, James

    2017-07-01

    Hyperspectral imaging has emerged as an important tool for analysing vegetation data in agricultural applications. Recently, low altitude and ground based hyperspectral imaging solutions have come to the fore, providing very high resolution data for mapping and studying large areas of crops in detail. However, these platforms introduce a unique set of challenges that need to be overcome to ensure consistent, accurate and timely acquisition of data. One particular problem is dealing with changes in environmental illumination while operating with natural light under cloud cover, which can have considerable effects on spectral shape. In the past this has been commonly achieved by imaging known reference targets at the time of data acquisition, direct measurement of irradiance, or atmospheric modelling. While capturing a reference panel continuously or very frequently allows accurate compensation for illumination changes, this is often not practical with ground based platforms, and impossible in aerial applications. This paper examines the use of an autonomous unmanned ground vehicle (UGV) to gather high resolution hyperspectral imaging data of crops under natural illumination. A process of illumination compensation is performed to extract the inherent reflectance properties of the crops, despite variable illumination. This work adapts a previously developed subspace model approach to reflectance and illumination recovery. Though tested on a ground vehicle in this paper, it is applicable to low altitude unmanned aerial hyperspectral imagery also. The method uses occasional observations of reference panel training data from within the same or other datasets, which enables a practical field protocol that minimises in-field manual labour. This paper tests the new approach, comparing it against traditional methods. Several illumination compensation protocols for high volume ground based data collection are presented based on the results. The findings in this paper are

  20. Compassion is a constant.

    Science.gov (United States)

    Scott, Tricia

    2015-11-01

    Compassion is a powerful word that describes an intense feeling of commiseration and a desire to help those struck by misfortune. Most people know intuitively how and when to offer compassion to relieve another person's suffering. In health care, compassion is a constant; it cannot be rationed because emergency nurses have limited time or resources to manage increasing demands.

  1. Lunar Polar Illumination for Power Analysis

    Science.gov (United States)

    Fincannon, James

    2008-01-01

    This paper presents illumination analyses using the latest Earth-based radar digital elevation model (DEM) of the lunar south pole and an independently developed analytical tool. These results enable the optimum sizing of solar/energy storage lunar surface power systems since they quantify the timing and durations of illuminated and shadowed periods. Filtering and manual editing of the DEM based on comparisons with independent imagery were performed and a reduced resolution version of the DEM was produced to reduce the analysis time. A comparison of the DEM with lunar limb imagery was performed in order to validate the absolute heights over the polar latitude range, the accuracy of which affects the impact of long range, shadow-casting terrain. Average illumination and energy storage duration maps of the south pole region are provided for the worst and best case lunar day using the reduced resolution DEM. Average illumination fractions and energy storage durations are presented for candidate low energy storage duration south pole sites. The best site identified using the reduced resolution DEM required a 62 hr energy storage duration using a fast recharge power system. Solar and horizon terrain elevations as well as illumination fraction profiles are presented for the best identified site and the data for both the reduced resolution and high resolution DEMs compared. High resolution maps for three low energy storage duration areas are presented showing energy storage duration for the worst case lunar day, surface height, and maximum absolute surface slope.

  2. Variation of fundamental constants

    CERN Document Server

    Flambaum, V V

    2006-01-01

    We present a review of recent works devoted to the variation of the fine structure constant alpha, strong interaction and fundamental masses. There are some hints for the variation in quasar absorption spectra, Big Bang nucleosynthesis, and Oklo natural nuclear reactor data. A very promising method to search for the variation of the fundamental constants consists in comparison of different atomic clocks. Huge enhancement of the variation effects happens in transition between accidentally degenerate atomic and molecular energy levels. A new idea is to build a ``nuclear'' clock based on the ultraviolet transition between very low excited state and ground state in Thorium nucleus. This may allow to improve sensitivity to the variation up to 10 orders of magnitude! Huge enhancement of the variation effects is also possible in cold atomic and molecular collisions near Feschbach resonance.

  3. Constant-pressure Blowers

    Science.gov (United States)

    Sorensen, E

    1940-01-01

    The conventional axial blowers operate on the high-pressure principle. One drawback of this type of blower is the relatively low pressure head, which one attempts to overcome with axial blowers producing very high pressure at a given circumferential speed. The Schicht constant-pressure blower affords pressure ratios considerably higher than those of axial blowers of conventional design with approximately the same efficiency.

  4. String Scale Cosmological Constant

    OpenAIRE

    Chalmers, Gordon

    2006-01-01

    The cosmological constant is an unexplained until now phenomena of nature that requires an explanation through string effects. The apparent discrepancy between theory and experiment is enourmous and has already been explained several times by the author including mechanisms. In this work the string theory theory of abolished string modes is documented and given perturbatively to all loop orders. The holographic underpinning is also exposed. The matching with the data of the LIGO and D0 experi...

  5. An illumination system for endoscopic applications

    DEFF Research Database (Denmark)

    2013-01-01

    The present disclosure relates to an illumination system for endoscopic applications comprising at least one substantially monochromatic light source having a predefined central wavelength between 400 and 500 nm or between 500 and 550 nm, an optical transmission path adapted to guide light...... emanating from the light source to an endoscopic region of examination, and an optical band-rejection filter, wherein the illumination system is adapted to illuminate at least a part of the region of examination by generating autofluorescence in surrounding tissue, and the band-rejection filter is adapted...... of a substantially monochromatic light source having a predefined central wavelength between 400 and 550 nm, means for guiding light from the substantially monochromatic light source towards at least a part of the tissue, and at least one band-rejection filter adapted to attenuate at least said central wavelength...

  6. Quantum Estimation Methods for Quantum Illumination.

    Science.gov (United States)

    Sanz, M; Las Heras, U; García-Ripoll, J J; Solano, E; Di Candia, R

    2017-02-17

    Quantum illumination consists in shining quantum light on a target region immersed in a bright thermal bath with the aim of detecting the presence of a possible low-reflective object. If the signal is entangled with the receiver, then a suitable choice of the measurement offers a gain with respect to the optimal classical protocol employing coherent states. Here, we tackle this detection problem by using quantum estimation techniques to measure the reflectivity parameter of the object, showing an enhancement in the signal-to-noise ratio up to 3 dB with respect to the classical case when implementing only local measurements. Our approach employs the quantum Fisher information to provide an upper bound for the error probability, supplies the concrete estimator saturating the bound, and extends the quantum illumination protocol to non-Gaussian states. As an example, we show how Schrödinger's cat states may be used for quantum illumination.

  7. Hybrid illumination systems for a brigth future

    DEFF Research Database (Denmark)

    Bjarklev, Araceli

    Problem to be adressed: Even with the implementation of the Eco-design directive (2005/32/EC) it is projected that the 20% energy reduction goal will not be reached in 2020. as a matter of fact, the electricity consumption in the illumination sector will not be changed from the levels of cosnsump......Problem to be adressed: Even with the implementation of the Eco-design directive (2005/32/EC) it is projected that the 20% energy reduction goal will not be reached in 2020. as a matter of fact, the electricity consumption in the illumination sector will not be changed from the levels...... of cosnsumption of 1990. To really get some savings, further improvements have to be done in the area of illumination systems. Our current research is aiming on fiinding- from an eco-designg perspective- precisly those alternative technological systems. Expected results: Withthe cooperation...

  8. Content adaptive illumination for Fourier ptychography.

    Science.gov (United States)

    Bian, Liheng; Suo, Jinli; Situ, Guohai; Zheng, Guoan; Chen, Feng; Dai, Qionghai

    2014-12-01

    Fourier ptychography (FP) is a recently reported technique, for large field-of-view and high-resolution imaging. Specifically, FP captures a set of low-resolution images, under angularly varying illuminations, and stitches them together in the Fourier domain. One of FP's main disadvantages is its long capturing process, due to the requisite large number of incident illumination angles. In this Letter, utilizing the sparsity of natural images in the Fourier domain, we propose a highly efficient method, termed adaptive Fourier ptychography (AFP), which applies content adaptive illumination for FP, to capture the most informative parts of the scene's spatial spectrum. We validate the effectiveness and efficiency of the reported framework, with both simulated and real experiments. Results show that the proposed AFP could shorten the acquisition time of conventional FP, by around 30%-60%.

  9. The Hubble Constant.

    Science.gov (United States)

    Jackson, Neal

    2015-01-01

    I review the current state of determinations of the Hubble constant, which gives the length scale of the Universe by relating the expansion velocity of objects to their distance. There are two broad categories of measurements. The first uses individual astrophysical objects which have some property that allows their intrinsic luminosity or size to be determined, or allows the determination of their distance by geometric means. The second category comprises the use of all-sky cosmic microwave background, or correlations between large samples of galaxies, to determine information about the geometry of the Universe and hence the Hubble constant, typically in a combination with other cosmological parameters. Many, but not all, object-based measurements give H0 values of around 72-74 km s(-1) Mpc(-1), with typical errors of 2-3 km s(-1) Mpc(-1). This is in mild discrepancy with CMB-based measurements, in particular those from the Planck satellite, which give values of 67-68 km s(-1) Mpc(-1) and typical errors of 1-2 km s(-1) Mpc(-1). The size of the remaining systematics indicate that accuracy rather than precision is the remaining problem in a good determination of the Hubble constant. Whether a discrepancy exists, and whether new physics is needed to resolve it, depends on details of the systematics of the object-based methods, and also on the assumptions about other cosmological parameters and which datasets are combined in the case of the all-sky methods.

  10. Universe of constant

    Science.gov (United States)

    Yongquan, Han

    2016-10-01

    The ideal gas state equation is not applicable to ordinary gas, it should be applied to the Electromagnetic ``gas'' that is applied to the radiation, the radiation should be the ultimate state of matter changes or initial state, the universe is filled with radiation. That is, the ideal gas equation of state is suitable for the Singular point and the universe. Maybe someone consider that, there is no vessel can accommodate radiation, it is because the Ordinary container is too small to accommodate, if the radius of your container is the distance that Light through an hour, would you still think it can't accommodates radiation? Modern scientific determinate that the radius of the universe now is about 1027 m, assuming that the universe is a sphere whose volume is approximately: V = 4.19 × 1081 cubic meters, the temperature radiation of the universe (cosmic microwave background radiation temperature of the universe, should be the closest the average temperature of the universe) T = 3.15k, radiation pressure P = 5 × 10-6 N / m 2, according to the law of ideal gas state equation, PV / T = constant = 6 × 1075, the value of this constant is the universe, The singular point should also equal to the constant Author: hanyongquan

  11. 30 CFR 57.17001 - Illumination of surface working areas.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Illumination of surface working areas. 57.17001 Section 57.17001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Illumination § 57.17001 Illumination of surface working areas. Illumination sufficient to provide safe...

  12. 30 CFR 56.17001 - Illumination of surface working areas.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Illumination of surface working areas. 56.17001... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Illumination § 56.17001 Illumination of surface working areas. Illumination sufficient to provide safe...

  13. 10 CFR 431.202 - Definitions concerning illuminated exit signs.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Definitions concerning illuminated exit signs. 431.202... COMMERCIAL AND INDUSTRIAL EQUIPMENT Illuminated Exit Signs § 431.202 Definitions concerning illuminated exit signs. Basic model means, with respect to illuminated exit signs, all units of a given type...

  14. Bifurcations in two-image photometric stereo for orthogonal illuminations

    Science.gov (United States)

    Kozera, R.; Prokopenya, A.; Noakes, L.; Śluzek, A.

    2017-07-01

    This paper discusses the ambiguous shape recovery in two-image photometric stereo for a Lambertian surface. The current uniqueness analysis refers to linearly independent light-source directions p = (0, 0, -1) and q arbitrary. For this case necessary and sufficient condition determining ambiguous reconstruction is governed by a second-order linear partial differential equation with constant coefficients. In contrast, a general position of both non-colinear illumination directions p and q leads to a highly non-linear PDE which raises a number of technical difficulties. As recently shown, the latter can also be handled for another family of orthogonal illuminations parallel to the OXZ-plane. For the special case of p = (0, 0, -1) a potential ambiguity stems also from the possible bifurcations of sub-local solutions glued together along a curve defined by an algebraic equation in terms of the data. This paper discusses the occurrence of similar bifurcations for such configurations of orthogonal light-source directions. The discussion to follow is supplemented with examples based on continuous reflectance map model and generated synthetic images.

  15. Illumination engineering design with nonimaging optics

    CERN Document Server

    Koshel, R John

    2012-01-01

    This book brings together experts in the field who present material on a number of important and growing topics including lighting, displays, solar concentrators. The first chapter provides an overview of the field of nonimagin and illumination optics. Included in this chapter are terminology, units, definitions, and descriptions of the optical components used in illumination systems. The next two chapters provide material within the theoretical domain, including etendue, etendue squeezing, and the skew invariant. The remaining chapters focus on growing applications. This entire field of

  16. Weld pool visual sensing without external illumination

    DEFF Research Database (Denmark)

    Liu, Jinchao; Fan, Zhun; Olsen, Soren Ingvor

    2011-01-01

    Visual sensing in arc welding has become more and more important, but still remains challenging because of the harsh environment with extremely strong illumination from the arc. This paper presents a low-cost camera-based sensor system, without using external Illumination, but nevertheless able...... to sense and model the weld pool. Central is a carefully selected optical filtering as well as an active contour-based tracking of the weld pool boundary. The system is able to extract the 2D shape of the weld pool in real time. The reported experiments show the feasibility of this approach....

  17. Resolution enhancement using simultaneous couple illumination

    Science.gov (United States)

    Hussain, Anwar; Martínez Fuentes, José Luis

    2016-10-01

    A super-resolution technique based on structured illumination created by a liquid crystal on silicon spatial light modulator (LCOS-SLM) is presented. Single and simultaneous pairs of tilted beams are generated to illuminate a target object. Resolution enhancement of an optical 4f system is demonstrated by using numerical simulations. The resulting intensity images are recorded at a charged couple device (CCD) and stored in the computer memory for further processing. One dimension enhancement can be performed with only 15 images. Two dimensional complete improvement requires 153 different images. The resolution of the optical system is extended three times compared to the band limited system.

  18. Scalable Fourier transform system for instantly structured illumination in lithography.

    Science.gov (United States)

    Ye, Yan; Xu, Fengchuan; Wei, Guojun; Xu, Yishen; Pu, Donglin; Chen, Linsen; Huang, Zhiwei

    2017-05-15

    We report the development of a unique scalable Fourier transform 4-f system for instantly structured illumination in lithography. In the 4-f system, coupled with a 1-D grating and a phase retarder, the ±1st order of diffracted light from the grating serve as coherent incident sources for creating interference patterns on the image plane. By adjusting the grating and the phase retarder, the interference fringes with consecutive frequencies, as well as their orientations and phase shifts, can be generated instantly within a constant interference area. We demonstrate that by adapting this scalable Fourier transform system into lithography, the pixelated nano-fringe arrays with arbitrary frequencies and orientations can be dynamically produced in the photoresist with high variation resolution, suggesting its promising application for large-area functional materials based on space-variant nanostructures in lithography.

  19. Brief Introduction ofChina Illuminating Engineering Journal

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    China Illuminating Engineering Journal,which wasfirst publishedinthe year1987,is a nationwide academic magazine sponsored by ChinaIlluminating Engineering Society(CIES).The goal ofChina IlluminatingEngineering Journalis to demonstrate the most advanced R&Dactivities ofilluminating science,the domestic and international state-of-the-art in thefield of illuminating engineering and the academic activities of Committee ofIlluminating Engineering(CIE)as well as other international illuminatingorganizations;relea...

  20. Rats

    Directory of Open Access Journals (Sweden)

    Alexey Kondrashov

    2012-01-01

    Full Text Available We aimed to perform a chemical analysis of both Alibernet red wine and an alcohol-free Alibernet red wine extract (AWE and to investigate the effects of AWE on nitric oxide and reactive oxygen species production as well as blood pressure development in normotensive Wistar Kyoto (WKY and spontaneously hypertensive rats (SHRs. Total antioxidant capacity together with total phenolic and selected mineral content was measured in wine and AWE. Young 6-week-old male WKY and SHR were treated with AWE (24,2 mg/kg/day for 3 weeks. Total NOS and SOD activities, eNOS and SOD1 protein expressions, and superoxide production were determined in the tissues. Both antioxidant capacity and phenolic content were significantly higher in AWE compared to wine. The AWE increased NOS activity in the left ventricle, aorta, and kidney of SHR, while it did not change NOS activity in WKY rats. Similarly, increased SOD activity in the plasma and left ventricle was observed in SHR only. There were no changes in eNOS and SOD1 expressions. In conclusion, phenolics and minerals included in AWE may contribute directly to increased NOS and SOD activities of SHR. Nevertheless, 3 weeks of AWE treatment failed to affect blood pressure of SHR.

  1. The Hubble Constant

    Directory of Open Access Journals (Sweden)

    Neal Jackson

    2015-09-01

    Full Text Available I review the current state of determinations of the Hubble constant, which gives the length scale of the Universe by relating the expansion velocity of objects to their distance. There are two broad categories of measurements. The first uses individual astrophysical objects which have some property that allows their intrinsic luminosity or size to be determined, or allows the determination of their distance by geometric means. The second category comprises the use of all-sky cosmic microwave background, or correlations between large samples of galaxies, to determine information about the geometry of the Universe and hence the Hubble constant, typically in a combination with other cosmological parameters. Many, but not all, object-based measurements give H_0 values of around 72–74 km s^–1 Mpc^–1, with typical errors of 2–3 km s^–1 Mpc^–1. This is in mild discrepancy with CMB-based measurements, in particular those from the Planck satellite, which give values of 67–68 km s^–1 Mpc^–1 and typical errors of 1–2 km s^–1 Mpc^–1. The size of the remaining systematics indicate that accuracy rather than precision is the remaining problem in a good determination of the Hubble constant. Whether a discrepancy exists, and whether new physics is needed to resolve it, depends on details of the systematics of the object-based methods, and also on the assumptions about other cosmological parameters and which datasets are combined in the case of the all-sky methods.

  2. Spaces of constant curvature

    CERN Document Server

    Wolf, Joseph A

    2010-01-01

    This book is the sixth edition of the classic Spaces of Constant Curvature, first published in 1967, with the previous (fifth) edition published in 1984. It illustrates the high degree of interplay between group theory and geometry. The reader will benefit from the very concise treatments of riemannian and pseudo-riemannian manifolds and their curvatures, of the representation theory of finite groups, and of indications of recent progress in discrete subgroups of Lie groups. Part I is a brief introduction to differentiable manifolds, covering spaces, and riemannian and pseudo-riemannian geomet

  3. Gnostic inner illumination and Carl Jung's individuation.

    Science.gov (United States)

    Pennachio, J

    1992-09-01

    The ancient religious system of Gnosticism argued for the transcendence of the physical world and the divinity of self-knowledge. More recently, a similar argument was made by Carl Jung through his concept of individuation. This paper examines some of the similarities between Gnostic inner illumination and Jung's concept of individuation.

  4. Public illumination manual; Manual de iluminacao publica

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-12-31

    This work aims to guide in the correct choice and usage of the adequate public illumination equipment. It also aims to help the public authorities in terms of the best economical and technical choice, as well as the adequate maintenance of the equipment in order to obtain the most efficiency and safety with minimum costs 22 figs., 11 tabs.

  5. 29 CFR 1926.56 - Illumination.

    Science.gov (United States)

    2010-07-01

    ... operation 5 General construction area lighting. 3 General construction areas, concrete placement, excavation...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Occupational Health and Environmental Controls § 1926.56 Illumination. (a) General. Construction areas, ramps, runways, corridors, offices, shops, and storage areas...

  6. Diffuse-Illumination Systems for Growing Plants

    Science.gov (United States)

    May, George; Ryan, Robert

    2010-01-01

    Agriculture in both terrestrial and space-controlled environments relies heavily on artificial illumination for efficient photosynthesis. Plant-growth illumination systems require high photon flux in the spectral range corresponding with plant photosynthetic active radiation (PAR) (400 700 nm), high spatial uniformity to promote uniform growth, and high energy efficiency to minimize electricity usage. The proposed plant-growth system takes advantage of the highly diffuse reflective surfaces on the interior of a sphere, hemisphere, or other nearly enclosed structure that is coated with highly reflective materials. This type of surface and structure uniformly mixes discrete light sources to produce highly uniform illumination. Multiple reflections from within the domelike structures are exploited to obtain diffuse illumination, which promotes the efficient reuse of photons that have not yet been absorbed by plants. The highly reflective surfaces encourage only the plant tissue (placed inside the sphere or enclosure) to absorb the light. Discrete light sources, such as light emitting diodes (LEDs), are typically used because of their high efficiency, wavelength selection, and electronically dimmable properties. The light sources are arranged to minimize shadowing and to improve uniformity. Different wavelengths of LEDs (typically blue, green, and red) are used for photosynthesis. Wavelengths outside the PAR range can be added for plant diagnostics or for growth regulation

  7. Measurement of illumination exposure in postpartum women

    Directory of Open Access Journals (Sweden)

    Stein Martin T

    2003-05-01

    Full Text Available Abstract Background Low levels of light exposure at critical times are thought to cause seasonal affective disorder. Investigators, in studies demonstrating the usefulness of bright light therapy, also have implicated light's role in non-seasonal depression. The precise cause of postpartum depression has not been delineated, but it seemed possible that new mothers would spend reduced time in daylight. The goal of this study was to examine the levels of illumination experienced by postpartum mothers and to discover any relationship between light exposure and mood levels experienced during the postpartum period. Methods Fifteen postpartum women, who did not have any baseline indication of depression, wore a wrist device (Actillume for 72 hours to measure their exposure to light. At the end of the recording period, they completed a self-reported measure of mood. The mean light exposure of these postpartum women (expressed as the 24-hour average logarithm of illumination in lux was compared with that of a representative sample of women of comparable age, residence, and seasonal months of recording. Mood levels were then rank-ordered and tested for correlation with light exposure levels. Results There was no significant difference between the amount of light [log10lux] experienced by postpartum (1.01 SD 0.236 and control women (1.06 SD 0.285. Mood was not correlated with illumination in the postpartum sample. Conclusions Postpartum women in San Diego did not receive reduced light, nor was low mood related to low illumination.

  8. Efficient illumination for microsecond tracking microscopy.

    Science.gov (United States)

    Dulin, David; Barland, Stephane; Hachair, Xavier; Pedaci, Francesco

    2014-01-01

    The possibility to observe microsecond dynamics at the sub-micron scale, opened by recent technological advances in fast camera sensors, will affect many biophysical studies based on particle tracking in optical microscopy. A main limiting factor for further development of fast video microscopy remains the illumination of the sample, which must deliver sufficient light to the camera to allow microsecond exposure times. Here we systematically compare the main illumination systems employed in holographic tracking microscopy, and we show that a superluminescent diode and a modulated laser diode perform the best in terms of image quality and acquisition speed, respectively. In particular, we show that the simple and inexpensive laser illumination enables less than 1 μs camera exposure time at high magnification on a large field of view without coherence image artifacts, together with a good hologram quality that allows nm-tracking of microscopic beads to be performed. This comparison of sources can guide in choosing the most efficient illumination system with respect to the specific application.

  9. Efficient illumination for microsecond tracking microscopy.

    Directory of Open Access Journals (Sweden)

    David Dulin

    Full Text Available The possibility to observe microsecond dynamics at the sub-micron scale, opened by recent technological advances in fast camera sensors, will affect many biophysical studies based on particle tracking in optical microscopy. A main limiting factor for further development of fast video microscopy remains the illumination of the sample, which must deliver sufficient light to the camera to allow microsecond exposure times. Here we systematically compare the main illumination systems employed in holographic tracking microscopy, and we show that a superluminescent diode and a modulated laser diode perform the best in terms of image quality and acquisition speed, respectively. In particular, we show that the simple and inexpensive laser illumination enables less than 1 μs camera exposure time at high magnification on a large field of view without coherence image artifacts, together with a good hologram quality that allows nm-tracking of microscopic beads to be performed. This comparison of sources can guide in choosing the most efficient illumination system with respect to the specific application.

  10. Deconvolution methods for structured illumination microscopy.

    Science.gov (United States)

    Chakrova, Nadya; Rieger, Bernd; Stallinga, Sjoerd

    2016-07-01

    We compare two recently developed multiple-frame deconvolution approaches for the reconstruction of structured illumination microscopy (SIM) data: the pattern-illuminated Fourier ptychography algorithm (piFP) and the joint Richardson-Lucy deconvolution (jRL). The quality of the images reconstructed by these methods is compared in terms of the achieved resolution improvement, noise enhancement, and inherent artifacts. Furthermore, we study the issue of object-dependent resolution improvement by considering the modulation transfer functions derived from different types of objects. The performance of the considered methods is tested in experiments and benchmarked with a commercial SIM microscope. We find that the piFP method resolves periodic and isolated structures equally well, whereas the jRL method provides significantly higher resolution for isolated objects compared to periodic ones. Images reconstructed by the piFP and jRL algorithms are comparable to the images reconstructed using the generalized Wiener filter applied in most commercial SIM microscopes. An advantage of the discussed algorithms is that they allow the reconstruction of SIM images acquired under different types of illumination, such as multi-spot or random illumination.

  11. Lit appearance modeling of illumination systems

    Science.gov (United States)

    Koshel, R. John

    2002-09-01

    In illumination systems the look and feel are often more important than objective criterion, such as uniformity and efficiency. The reason for this is two fold: the lit appearance often sells an item and substantial variation in the illumination distribution (up to 50%) over a broad region is not noticeable to an observer. Therefore, subjective criterion, such as the lit appearance, typically plays a crucial role in the development of an illumination system. Additionally, by using computer models to ascertain the lit appearance before manufacture of the system, it allows the designer to modify the system while not demanding investment to produce prototypes. I discuss methods of determining the lit appearance for illumination systems. This modeling includes the inclusion of material and surface properties, such as surface finish, spectral transmission, and internal scattering; the response of the human eye; and the amount of rays that must be traced. By archiving the ray data, animations as a function of position and angle can be developed. Examples are developed to highlight the utility of this technique. These examples include taillights for the automotive industry and a backlit LCD screen for a laptop. Animations of these models demonstrate their luminance.

  12. Daylight illumination-color-contrast tables for full-form objects naturally illuminated objects

    CERN Document Server

    Nagel, M

    1978-01-01

    Daylight Illumination-Color-Contrast Tables for Full-form Objects is the result of a major computational project concerning the illumination, color, and contrast conditions in naturally illuminated objects. The project from which this two-chapter book is derived is originally conceived in support of the various remote sensing and image processing activities of the Deutsche Forschungs- und Versuchsanstalt für Luft- und Raumfahrt, Oberpfaffenhofen, West Germany DFVLR, in particular, those depending on the quantitative photometric and colorimetric evaluation of photographs and other environmental

  13. Color appearance of familiar objects: effects of object shape, texture, and illumination changes.

    Science.gov (United States)

    Olkkonen, Maria; Hansen, Thorsten; Gegenfurtner, Karl R

    2008-05-26

    People perceive roughly constant surface colors despite large changes in illumination. The familiarity of colors of some natural objects might help achieve this feat through direct modulation of the objects' color appearance. Research on memory colors and color appearance has yielded controversial results and due to the employed methods has often confounded perceptual with semantic effects. We studied the effect of memory colors on color appearance by presenting photographs of fruit on a monitor under various simulated illuminations and by asking observers to make either achromatic or typical color settings without placing demands on short-term memory or semantic processing. In a control condition, we presented photographs of 3D fruit shapes without texture and 2D outline shapes. We found that (1) achromatic settings for fruit were systematically biased away from the gray point toward the opposite direction of a fruit's memory color; (2) the strength of the effect depended on the degree of naturalness of the stimuli; and (3) the effect was evident under all tested illuminations, being strongest for illuminations whose chromaticity was closest to the stimulus chromaticity. We conclude that the visual identity of an object has a measurable effect on color perception, and that this effect is robust under illuminant changes, indicating its potential significance as an additional mechanism for color constancy.

  14. The Hubble Constant

    Directory of Open Access Journals (Sweden)

    Jackson Neal

    2007-09-01

    Full Text Available I review the current state of determinations of the Hubble constant, which gives the length scale of the Universe by relating the expansion velocity of objects to their distance. In the last 20 years, much progress has been made and estimates now range between 60 and 75 km s^-1 Mpc^-1, with most now between 70 and 75 km s^-1 Mpc^-1, a huge improvement over the factor-of-2 uncertainty which used to prevail. Further improvements which gave a generally agreed margin of error of a few percent rather than the current 10% would be vital input to much other interesting cosmology. There are several programmes which are likely to lead us to this point in the next 10 years.

  15. When constants are important

    Energy Technology Data Exchange (ETDEWEB)

    Beiu, V.

    1997-04-01

    In this paper the authors discuss several complexity aspects pertaining to neural networks, commonly known as the curse of dimensionality. The focus will be on: (1) size complexity and depth-size tradeoffs; (2) complexity of learning; and (3) precision and limited interconnectivity. Results have been obtained for each of these problems when dealt with separately, but few things are known as to the links among them. They start by presenting known results and try to establish connections between them. These show that they are facing very difficult problems--exponential growth in either space (i.e. precision and size) and/or time (i.e., learning and depth)--when resorting to neural networks for solving general problems. The paper will present a solution for lowering some constants, by playing on the depth-size tradeoff.

  16. Constant Proportion Portfolio Insurance

    DEFF Research Database (Denmark)

    Jessen, Cathrine

    2014-01-01

    Portfolio insurance, as practiced in 1987, consisted of trading between an underlying stock portfolio and cash, using option theory to place a floor on the value of the position, as if it included a protective put. Constant Proportion Portfolio Insurance (CPPI) is an option-free variation...... on the theme, originally proposed by Fischer Black. In CPPI, a financial institution guarantees a floor value for the “insured” portfolio and adjusts the stock/bond mix to produce a leveraged exposure to the risky assets, which depends on how far the portfolio value is above the floor. Plain-vanilla portfolio...... insurance largely died with the crash of 1987, but CPPI is still going strong. In the frictionless markets of finance theory, the issuer’s strategy to hedge its liability under the contract is clear, but in the real world with transactions costs and stochastic jump risk, the optimal strategy is less obvious...

  17. Decay constants in geochronology

    Institute of Scientific and Technical Information of China (English)

    IgorM.Villa; PaulR.Renne

    2005-01-01

    Geologic time is fundamental to the Earth Sciences, and progress in many disciplines depends critically on our ability to measure time with increasing accuracy and precision. Isotopic geochronology makes use of the decay of radioactive nuclides as a help to quantify the histories of rock, minerals, and other materials. Both accuracy and precision of radioisotopic ages are, at present, limited by those of radioactive decay constants. Modem mass spectrometers can measure isotope ratios with a precision of 10-4 or better. On the other hand, the uncertainties associated with direct half-life determinations are, in most cases, still at the percent level. The present short note briefly summarizes progress and problems that have been encountered during the Working Group's activity.

  18. Influences of the illumination coherency and illumination aperture on the ptychographic iterative microscopy

    Institute of Scientific and Technical Information of China (English)

    刘诚; 朱健强; John Rodenburg

    2015-01-01

    While ptychography is an algorithm based on coherent illumination, the satisfactory reconstructions can still be gen-erated in most of experiments though the radiation sources used are not ideally coherent. The underlying physics of this phenomenon is that the diffraction patterns of partially coherent illumination can be treated as those of purely coherent illumination by altering the intensities of the diffracted beams relative to their real values. On the other hand, due to the inconsistency in the altering interference among all the diffraction beams, the noise/distortion is always involved in the reconstructed images. Furthermore, for a weak object, the noise/distortion in the reconstruction can be mostly reduced by using highly curved beam for illumination in the data recording and forcing the dark field diffraction to be zero in the reconstruction.

  19. Illumination normalization of face image based on illuminant direction estimation and improved Retinex.

    Directory of Open Access Journals (Sweden)

    Jizheng Yi

    Full Text Available Illumination normalization of face image for face recognition and facial expression recognition is one of the most frequent and difficult problems in image processing. In order to obtain a face image with normal illumination, our method firstly divides the input face image into sixteen local regions and calculates the edge level percentage in each of them. Secondly, three local regions, which meet the requirements of lower complexity and larger average gray value, are selected to calculate the final illuminant direction according to the error function between the measured intensity and the calculated intensity, and the constraint function for an infinite light source model. After knowing the final illuminant direction of the input face image, the Retinex algorithm is improved from two aspects: (1 we optimize the surround function; (2 we intercept the values in both ends of histogram of face image, determine the range of gray levels, and stretch the range of gray levels into the dynamic range of display device. Finally, we achieve illumination normalization and get the final face image. Unlike previous illumination normalization approaches, the method proposed in this paper does not require any training step or any knowledge of 3D face and reflective surface model. The experimental results using extended Yale face database B and CMU-PIE show that our method achieves better normalization effect comparing with the existing techniques.

  20. Structured illumination microscopy and its new developments

    Directory of Open Access Journals (Sweden)

    Jianling Chen

    2016-05-01

    Full Text Available Optical microscopy allows us to observe the biological structures and processes within living cells. However, the spatial resolution of the optical microscopy is limited to about half of the wavelength by the light diffraction. Structured illumination microscopy (SIM, a type of new emerging super-resolution microscopy, doubles the spatial resolution by illuminating the specimen with a patterned light, and the sample and light source requirements of SIM are not as strict as the other super-resolution microscopy. In addition, SIM is easier to combine with the other imaging techniques to improve their imaging resolution, leading to the developments of diverse types of SIM. SIM has great potential to meet the various requirements of living cells imaging. Here, we review the recent developments of SIM and its combination with other imaging techniques.

  1. Insulator Surface Flashover Due to UV Illumination

    Energy Technology Data Exchange (ETDEWEB)

    Javedani, J B; Houck, T L; Lahowe, D A; Vogtlin, G E; Goerz, D A

    2009-07-27

    The surface of an insulator under vacuum and under electrical charge will flashover when illuminated by a critical dose of ultra-violet (UV) radiation - depending on the insulator size and material, insulator cone angle, the applied voltage and insulator shot-history. A testbed comprised of an excimer laser (KrF, 248 nm, {approx}16 MW, 30 ns FWHM,), a vacuum chamber, and a negative polarity dc high voltage power supply ({le} -60 kV) were assembled to test 1.0 cm thick angled insulators for surface-flashover. Several candidate insulator materials, e.g. High Density Polyethylene (HDPE), Rexolite{reg_sign} 1400, Macor{trademark} and Mycalex, of varying cone angles were tested against UV illumination. Commercial energy meters were used to measure the UV fluence of the pulsed laser beam. In-house designed and fabricated capacitive probes (D-dots, >12 GHz bandwidth) were embedded in the anode electrode underneath the insulator to determine the time of UV arrival and time of flashover. Of the tested insulators, the +45 degree Rexolite insulator showed more resistance to UV for surface flashover; at UV fluence level of less than 13 mJ/cm{sup 2}, it was not possible to induce a flashover for up to -60 kV of DC potential across the insulator's surface. The probes also permitted the electrical charge on the insulator before and after flashover to be inferred. Photon to electron conversion efficiency for the surface of Rexolite insulator was determined from charge-balance equation. In order to understand the physical mechanism leading to flashover, we further experimented with the +45 degree Rexolite insulator by masking portions of the UV beam to illuminate only a section of the insulator surface; (1) the half nearest the cathode and subsequently, (2) the half nearest the anode. The critical UV fluence and time to flashover were measured and the results in each case were then compared with the base case of full-beam illumination. It was discovered that the time for the

  2. Illuminating the Nights in Rural Communities

    Directory of Open Access Journals (Sweden)

    Dr. Achara N

    2014-11-01

    Full Text Available Electric power supply in many cities in developing countries is erratic and can only be described as non-existent in the rural areas. Kerosene lantern, the main source of illuminating the night is associated with obnoxious fumes production and more especially the kerosene fuel is scarce to find. Rural dwellers who cannot afford the globed kerosene lanterns either use the locally fabricated globeless kerosene lanterns, ―atunja‖ or log fire. Log fire is associated with deforestation and desert encroachment. A solar lantern has been designed and built for illuminating the nights in rural communities. Battery and LED are part of the components used and it is recommended that appropriate safety measures are put in place not only in use but also in their disposal.

  3. Development of a new illumination procedure for photodynamic therapy of the abdominal cavity

    Science.gov (United States)

    Guyon, Laurie; Claude Lesage, Jean; Betrouni, Nacim; Mordon, Serge

    2012-03-01

    A homogeneous illumination of intra-abdominal organs is essential for successful photodynamic therapy of the abdominal cavity. Considering the current lack of outstanding light-delivery systems, a new illumination procedure was assessed. A rat model of peritoneal carcinomatosis was used. Four hours after intraperitoneal injection of hexaminolevulinate, a square illuminating panel connected to a 635-nm laser source was inserted vertically into the abdominal cavity. The abdominal incision was sutured and a pneumoperitoneum created prior to illumination. Light dosimetry was based on the calculation of the peritoneal surface by MRI. The rats were treated with a light dose of 20, 10, 5 or 2.5 J/cm2 administered continuously with an irradiance of 7 mW/cm2. The homogeneity of the cavity illumination was assessed by quantification of the photobleaching of the tumor lesions according to their localization and by scoring of that of the liver and of the bowel immediately after treatment. Photobleaching quantification for tumor lesions relied on the calculation of the fluorescence intensity ratio (after/before treatment) after recording of the lesions during blue-light laparoscopy and determination of their fluorescence intensity with Sigmascan Pro software. The procedure led to a homogeneous treatment of the abdominal cavity. No statistical difference was observed for the photobleaching values according to the localization of the lesions on the peritoneum (p=0.59) and photobleaching of the liver and of the intestine was homogeneous. We conclude that this procedure can successfully treat the major sites involved in peritoneal carcinomatosis.

  4. Simulating Human Visual Perception in Nighttime Illumination

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ning; DONG Weiming; WANG Jiaxin; Paul Jean-Claude

    2009-01-01

    This paper presents an image-based algorithm for simulating the visual adaptation of the human visual system to various illuminations,especially in dark nighttime conditions.The human visual system exhibits different characteristics depending on the illumination intensity,with photopic vision in bright conditions,scotopic vision in dark conditions,and mesopic vision between these two.A computational model is designed to simulate multiple features of mesopic vision and scotopic vision,including the chromaticity change,luminance change,and visual acuity loss.The system uses a source image under bright illumination as input.Then assuming that the viewer has already adapted to the new conditions,the color spectrum of the input image is reconstructed to replace the source with modifications of the chromaticity and the luminance of the relighted scene.A bilateral filter is used to simulate the visual acuity loss.The model parameters have clear physical meanings and can be obtained from experimental data to achieve realistic results.The algorithm can be used not only for visual perception simulation,but also as a day-for-night tool to produce realistic nighttime images from daytime images.

  5. 47 CFR 80.969 - Illumination of operating controls.

    Science.gov (United States)

    2010-10-01

    ... illuminate the operating controls at the principal operating position. (b) Instead of dial lights, a light from an electric lamp may be provided to illuminate the operating controls of the radiotelephone at...

  6. Stability of the Third Generation Intensifier under Illumination

    Institute of Scientific and Technical Information of China (English)

    DU Xiao-qing; DU Yu-jie; CHANG Ben-kang

    2005-01-01

    The stability under illumination of transmission-mode GaAs photocathode sealed in the third generation intensifier is investigated by use of spectral response testing instruments. The variations of spectral response with the illumination times under weak and intense illumination are compared. The variations of photoemission performance parameters are also characterized. The results show that during initial several weak illuminations photocathode behaves no evident decay and a maximum sensitivity is achieved, while under intense illumination the sensitivity of photocathode begin to decrease largely at the first illumination. The calculated performance parameters show that the variation of surface escape probability with illumination times is a direct cause of instability of photocathode. It is also found that under intense illumination peak wavelength is moved towards short-wave and peak response is decreased, which shows that the ability of long-wave response of photocathode is decreased.

  7. The Interacting and Non-constant Cosmological Constant

    CERN Document Server

    Verma, Murli Manohar

    2009-01-01

    We propose a time-varying cosmological constant with a fixed equation of state, which evolves mainly through its interaction with the background during most of the long history of the universe. However, such interaction does not exist in the very early and the late-time universe and produces the acceleration during these eras when it becomes very nearly a constant. It is found that after the initial inflationary phase, the cosmological constant, that we call as lambda parameter, rolls down from a large constant value to another but very small constant value and further dominates the present epoch showing up in form of the dark energy driving the acceleration.

  8. Quantum Theory without Planck's Constant

    CERN Document Server

    Ralston, John P

    2012-01-01

    Planck's constant was introduced as a fundamental scale in the early history of quantum mechanics. We find a modern approach where Planck's constant is absent: it is unobservable except as a constant of human convention. Despite long reference to experiment, review shows that Planck's constant cannot be obtained from the data of Ryberg, Davisson and Germer, Compton, or that used by Planck himself. In the new approach Planck's constant is tied to macroscopic conventions of Newtonian origin, which are dispensable. The precision of other fundamental constants is substantially improved by eliminating Planck's constant. The electron mass is determined about 67 times more precisely, and the unit of electric charge determined 139 times more precisely. Improvement in the experimental value of the fine structure constant allows new types of experiment to be compared towards finding "new physics." The long-standing goal of eliminating reliance on the artifact known as the International Prototype Kilogram can be accompl...

  9. Evaluation of low level laser therapy irradiation parameters on rat muscle inflammation through systemic blood cytokines

    Science.gov (United States)

    Mantineo, Matias; Pinheiro, João. P.; Morgado, António M.

    2014-02-01

    Low level laser therapy (LLLT) has been used for inflammation treatment. Here, we evaluate the effect of different doses, using continuous (830 and 980 nm) and pulsed illumination (830 nm), in the treatment of inflammation induced in the gastrocnemius muscle of Wistar rats, through cytokines concentration in systemic blood and histological analysis of muscle tissue. Animals were randomly divided into five groups per wavelength (5 animals per group: 10, 20, 30, 40 and 50 mW) plus a control group. LLLT was applied during five days, with constant exposure time and irradiated area (3 minutes; 0.5026 cm2). Blood was collected on days 0, 3 and 6. TNF-α, IL-1β, IL-2 and IL-6 cytokines were quantified by ELISA. Rats were killed on day 6. Muscle inflammatory cells were counted using optical microscopy. Treatment effects occurred for all applied doses (largest effect at 40 mW: 7.2 J, 14 J/cm2 per irradiation), with reduction of proinflammatory TNF-α, IL-1β and IL-6 cytokines and lower number of inflammatory cells. Results were better for 830 nm. Identical methodology was used with pulsed illumination. Average power (40 mW) and duty cycle were kept constant (80%) at five frequencies (5, 25, 50, 100 and 200 Hz). Treatment effects were observed at higher frequencies, with no significant differences between them. However, the treatment effect was lower than for continuous illumination. LLLT effect on inflammation treatment can be monitored by measuring systemic blood cytokines. A larger treatment effect was observed with continuous illumination, where results seem to be compatible with a biphasic dose response.

  10. Spiraling Beam Illumination Uniformity on Heavy Ion Fusion Target

    OpenAIRE

    Kurosaki, T; Kawata, S.; Noguchi, K.; Koseki, S; Barada, D.; Ma, Y. Y.; Ogoyski, A. I.; Barnard, J. J.; Logan, B. G.

    2012-01-01

    A few percent wobbling-beam illumination nonuniformity is realized in heavy ion inertial confinement fusion (HIF) by a spiraling beam axis motion in the paper. So far the wobbling heavy ion beam (HIB) illumination was proposed to realize a uniform implosion in HIF. However, the initial imprint of the wobbling HIBs was a serious problem and introduces a large unacceptable energy deposition nonuniformity. In the wobbling HIBs illumination, the illumination nonuniformity oscillates in time and s...

  11. S-sequence patterned illumination iterative photoacoustic tomography.

    Science.gov (United States)

    Harrison, Tyler; Shao, Peng; Zemp, Roger J

    2014-09-01

    Quantitatively reconstructing optical absorption using photoacoustic imaging is nontrivial. Theoretical hurdles, such as nonuniqueness and numerical instability, can be mitigated by using multiple illuminations. However, even with multiple illuminations, using ANSI-safety-limited fluence for practical imaging may result in poor performance owing to limited signal-to-noise ratio (SNR). We demonstrate the use of S-sequence coded patterned illumination to boost SNR while preserving the enhanced stability of multiple-illumination iterative techniques.

  12. Reflector Design Method for Rotational Uniform Illuminance System with LED

    Institute of Scientific and Technical Information of China (English)

    ZHANG Qi-hui; WANG Hong; JI Ling-ling

    2009-01-01

    Based on nonimaging design method,uniform illuminance systems with LED source were developed to create a uniform illuminated circular region with a desired size in a screen at a prescribed place.By using ray-tracing software based on Monte-Carlo method,the simulation results show that in the illuminated region the luminous uniformity is higher than 90%.

  13. Model-based reconstruction for illumination variation in face images

    NARCIS (Netherlands)

    Boom, B.J.; Spreeuwers, Lieuwe Jan; Veldhuis, Raymond N.J.

    2008-01-01

    We propose a novel method to correct for arbitrary illumination variation in the face images. The main purpose is to improve recognition results of face images taken under uncontrolled illumination conditions. We correct the illumination variation in the face images using a face shape model, which

  14. 32 CFR 707.10 - Wake illumination light.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Wake illumination light. 707.10 Section 707.10... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.10 Wake illumination light. Naval vessels may display a white spot light located near the stern to illuminate the wake....

  15. 21 CFR 886.1160 - Color vision plate illuminator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp...

  16. Open LED Illuminator: A Simple and Inexpensive LED Illuminator for Fast Multicolor Particle Tracking in Neurons

    Science.gov (United States)

    Bosse, Jens B.; Tanneti, Nikhila S.; Hogue, Ian B.; Enquist, Lynn W.

    2015-01-01

    Dual-color live cell fluorescence microscopy of fast intracellular trafficking processes, such as axonal transport, requires rapid switching of illumination channels. Typical broad-spectrum sources necessitate the use of mechanical filter switching, which introduces delays between acquisition of different fluorescence channels, impeding the interpretation and quantification of highly dynamic processes. Light Emitting Diodes (LEDs), however, allow modulation of excitation light in microseconds. Here we provide a step-by-step protocol to enable any scientist to build a research-grade LED illuminator for live cell microscopy, even without prior experience with electronics or optics. We quantify and compare components, discuss our design considerations, and demonstrate the performance of our LED illuminator by imaging axonal transport of herpes virus particles with high temporal resolution. PMID:26600461

  17. Open LED Illuminator: A Simple and Inexpensive LED Illuminator for Fast Multicolor Particle Tracking in Neurons.

    Directory of Open Access Journals (Sweden)

    Jens B Bosse

    Full Text Available Dual-color live cell fluorescence microscopy of fast intracellular trafficking processes, such as axonal transport, requires rapid switching of illumination channels. Typical broad-spectrum sources necessitate the use of mechanical filter switching, which introduces delays between acquisition of different fluorescence channels, impeding the interpretation and quantification of highly dynamic processes. Light Emitting Diodes (LEDs, however, allow modulation of excitation light in microseconds. Here we provide a step-by-step protocol to enable any scientist to build a research-grade LED illuminator for live cell microscopy, even without prior experience with electronics or optics. We quantify and compare components, discuss our design considerations, and demonstrate the performance of our LED illuminator by imaging axonal transport of herpes virus particles with high temporal resolution.

  18. Ultra Deep Wave Equation Imaging and Illumination

    Energy Technology Data Exchange (ETDEWEB)

    Alexander M. Popovici; Sergey Fomel; Paul Sava; Sean Crawley; Yining Li; Cristian Lupascu

    2006-09-30

    In this project we developed and tested a novel technology, designed to enhance seismic resolution and imaging of ultra-deep complex geologic structures by using state-of-the-art wave-equation depth migration and wave-equation velocity model building technology for deeper data penetration and recovery, steeper dip and ultra-deep structure imaging, accurate velocity estimation for imaging and pore pressure prediction and accurate illumination and amplitude processing for extending the AVO prediction window. Ultra-deep wave-equation imaging provides greater resolution and accuracy under complex geologic structures where energy multipathing occurs, than what can be accomplished today with standard imaging technology. The objective of the research effort was to examine the feasibility of imaging ultra-deep structures onshore and offshore, by using (1) wave-equation migration, (2) angle-gathers velocity model building, and (3) wave-equation illumination and amplitude compensation. The effort consisted of answering critical technical questions that determine the feasibility of the proposed methodology, testing the theory on synthetic data, and finally applying the technology for imaging ultra-deep real data. Some of the questions answered by this research addressed: (1) the handling of true amplitudes in the downward continuation and imaging algorithm and the preservation of the amplitude with offset or amplitude with angle information required for AVO studies, (2) the effect of several imaging conditions on amplitudes, (3) non-elastic attenuation and approaches for recovering the amplitude and frequency, (4) the effect of aperture and illumination on imaging steep dips and on discriminating the velocities in the ultra-deep structures. All these effects were incorporated in the final imaging step of a real data set acquired specifically to address ultra-deep imaging issues, with large offsets (12,500 m) and long recording time (20 s).

  19. Image Correlation Microscopy for Uniform Illumination

    Science.gov (United States)

    Gaborski, Thomas R.; Sealander, Michael N.; Ehrenberg, Morton; Waugh, Richard E.; McGrath, James L.

    2011-01-01

    Image cross-correlation microscopy (ICM) is a technique that quantifies the motion of fluorescent features in an image by measuring the temporal autocorrelation function decay in a time-lapse image sequence. ICM has traditionally employed laser-scanning microscopes because the technique emerged as an extension of laser-based fluorescence correlation spectroscopy (FCS). In this work, we show that image correlation can also be used to measure fluorescence dynamics in uniform illumination or wide-field imaging systems and we call our new approach uniform illumination image correlation microscopy (UI-ICM). Wide-field microscopy is not only a simpler, less expensive imaging modality, but it offers the capability of greater temporal resolution over laser-scanning systems. In traditional laser-scanning ICM, lateral mobility is calculated from the temporal de-correlation of an image, where the characteristic length is the illuminating laser beam width. In wide-field microscopy, the diffusion length is defined by the feature size using the spatial autocorrelation function (SACF). Correlation function decay in time occurs as an object diffuses from its original position. We show that theoretical and simulated comparisons between Gaussian and uniform features indicate the temporal autocorrelation function (TACF) depends strongly on particle size and not particle shape. In this report, we establish the relationships between the SACF feature size, TACF characteristic time and the diffusion coefficient for UI-ICM using analytical, Monte-Carlo and experimental validation with particle tracking algorithms. Additionally, we demonstrate UI-ICM analysis of adhesion molecule domain aggregation and diffusion on the surface of human neutrophils. PMID:20055917

  20. Light engine for an illumination device

    DEFF Research Database (Denmark)

    2015-01-01

    Disclosed herein are embodiments of a light engine for an illumination device, the light engine defining an output gate and being configured to output light from said output gate; wherein the light engine comprises: one or more light sources defining a light-emitting area; a concave reflector...... configured to receive light from the light-emitting area and to direct light from respective portions of the light-emitting area to form a converging beam that converges towards a beam spot at the output gate....

  1. A study about illumination and colors vision

    Energy Technology Data Exchange (ETDEWEB)

    Toadere, Florin, E-mail: florin.toadere@itim-cj.r [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania)

    2009-08-01

    In this paper we propose a software algorithm which can simulate the human eyes colors view. We present a spectral image processing algorithm, in which we use the color checker spectral image, the human eyes cones spectral sensitivity and the spectral power distribution for light sources. We use three spectrums of real lamps, made by EG and G PerkinElmer: sunlight 5500K, xenon flash and xenon CW, and three CIE light standard sources: D65, CIE A and F7. In order to validate the functionality of the algorithm we simulate the color checker picture hues difference, under different illuminations generate with the light spectrums presented in this paper.

  2. HMC and fibroblast illuminating experiments using microdisplay

    Science.gov (United States)

    Ou, Chung-Jen; Shen, Ching-I.; Ou, Chung-Ming

    2010-02-01

    Techniques like optical neural guiding, photodynamic therapy and photosynthesis of the cell all required specific spatial energy distribution. Influences factors like the wavelength, polarization, spatial intensity distribution are all required, and the appropriate illumination condition for the cells inside the incubator are required to meet more complicated conditions. We report the system that using of the spatial light modulator to provide a multi-points control for the cell culturing. This system is modified from the commercialized projection system to reduce the cost. It is now possible to apply it to other bio-culturing related applications. Results for Human Melanocyte HMC, Glia cell and fibroblast cell are discussed.

  3. Optical-sectioning microscopy by patterned illumination

    Science.gov (United States)

    Saavedra, G.; Martinez-Corral, M.; Sanchez-Ortiga, E.; Doblas, A.

    2010-02-01

    We propose a very simple method for the flexible production of 1D structured illumination for high resolution 3D microscopy. Specifically, we propose the insertion of a Fresnel biprism after a monochromatic point source for producing a pair of twin, fully coherent, virtual point sources. The resulting interference fringes are projected into the 3D sample and, by simply varying the distance between the biprism and the point source, one can tune the period of the fringes, while keeping their contrast, in a very versatile and efficient way.

  4. Sensation of rotation about a vertical axis with a fixed visual field in different illuminations and in the dark

    Science.gov (United States)

    Huang, J.; Young, L. R.

    1981-01-01

    The effects of the oculogyro illusion of the relative motion of a spot fixed with respect to the subject during subject rotation and of a fixed striped peripheral visual field under different levels of illumination on perceptions of rotation about a vertical axis are investigated. Subjects were seated in a rotatable flight trainer cockpit with visual fields consisting of darkness, a dim peripheral field, and a bright peripheral field, all fixed with respect to the subject, and subject perceptual thresholds, frequency responses and sensations of displacement and velocity were measured during trainer rotation at constant and varying angular accelerations. The perception of angular acceleration is found to exhibit a significantly lower threshold and a reduced latency time in the illuminated visual fields which was independent of the level of illumination. Subjective frequency responses showed a higher gain in the illuminated presentations, while subjective displacements during triangular velocity stimuli exhibited no difference for the different visual cues. Finally, magnitude estimations of the after-rotation associated with deceleration from a constant velocity showed a greater rising speed, larger velocity and longer duration under illumination. Results show that, for low accelerations, the visual input enhances sensitivity to self-motion, an effect explained by the oculogyral illusion.

  5. Kinetics of the permanent deactivation of the boron-oxygen complex in crystalline silicon as a function of illumination intensity

    Science.gov (United States)

    Steckenreiter, Verena; Walter, Dominic C.; Schmidt, Jan

    2017-03-01

    Based on contactless carrier lifetime measurements performed on p-type boron-doped Czochralski-grown silicon (Cz-Si) wafers, we examine the rate constant Rde of the permanent deactivation process of the boron-oxygen-related defect center as a function of the illumination intensity I at 170°C. While at low illumination intensities, a linear increase of Rde on I is measured, at high illumination intensities, Rde seems to saturate. We are able to explain the saturation by assuming that Rde increases proportionally with the excess carrier concentration Δ n and take the fact into account that at sufficiently high illumination intensities, the carrier lifetime decreases with increasing Δ n and hence the slope of Δ n (I) decreases, leading to an apparent saturation. Importantly, on low-lifetime Cz-Si samples no saturation of the deactivation rate constant is observed for the same illumination intensities, proving that the deactivation is stimulated by the presence of excess electrons and not directly by the photons.

  6. Development of flying spot illumination system for stage lighting

    Science.gov (United States)

    Asakawa, Hisashi; Ishii, Katsunori; Koshiro, Hikari; Baba, Junko; Wakaki, Moriaki

    2014-02-01

    The system to control the area of illumination is important for the luminaires used for stages and TV studios. Presently the methods to change the distance between a lamp and lenses, or to use a zooming projection of the aperture illuminated by the lamp are used to control the area. However, these methods require many optical components or mechanical components. Moreover, the energy of the light source is partially consumed by the absorption of the shutter on adjusting the illumination area. On the other hand, the control of the illuminance over the illuminated area is not possible by the methods. In this study, we developed the lighting system which enables to control both the illuminated area and the illuminance distribution within the area by scanning the beam from a LED array light source. The area of illumination was expanded along one dimension by scanning the LED beam using a rotating polygon mirror. The selection of the illuminated width and the control of the illuminance distribution were achieved by synchronizing the pulse width modulation (PWM) control of the LED with the rotation of the mirror using a time sharing control. As a result, various illuminance distributions can be realized at real time by using software control for the luminaire. The developed system has the merits of compact and high efficiency.

  7. Spiraling Beam Illumination Uniformity on Heavy Ion Fusion Target

    CERN Document Server

    Kurosaki, T; Noguchi, K; Koseki, S; Barada, D; Ma, Y Y; Ogoyski, A I; Barnard, J J; Logan, B G

    2012-01-01

    A few percent wobbling-beam illumination nonuniformity is realized in heavy ion inertial confinement fusion (HIF) by a spiraling beam axis motion in the paper. So far the wobbling heavy ion beam (HIB) illumination was proposed to realize a uniform implosion in HIF. However, the initial imprint of the wobbling HIBs was a serious problem and introduces a large unacceptable energy deposition nonuniformity. In the wobbling HIBs illumination, the illumination nonuniformity oscillates in time and space. The oscillating-HIB energy deposition may contribute to the reduction of the HIBs illumination nonuniformity. The wobbling HIBs can be generated in HIB accelerators and the oscillating frequency may be several 100MHz-1GHz. Three-dimensional HIBs illumination computations presented here show that the few percent wobbling HIBs illumination nonuniformity oscillates successfully with the same wobbling HIBs frequency.

  8. Active illumination and appearance model for face alignment

    DEFF Research Database (Denmark)

    Kahraman, Fatih; Gokmen, M.; Darkner, Sune

    2010-01-01

    Illumination conditions have an explicit effect on the performance of face recognition systems. In particular, varying the illumination upon the face imposes such, complex effects that the identification often fails to provide a stable performance level. In this paper, we propose an approach......, integrating face identity and illumination models in order to reach acceptable and stable face recognition rates. For this purpose, Active Appearance Model (A AM) and illumination model of faces are combined in order to obtain an illumination invariant face localization. The proposed method is an integrated......, is sufficient. There is no need to build complex models for illumination. As a result, this paper has presented a simple and efficient method for face modeling and face alignment in order to increase the performance of face localization by means of the proposed illumination invariant AIA method for face...

  9. Effect of illumination on linear and nonlinear optical parameters of Ga5Se95 thin films

    Science.gov (United States)

    Zedan, I. T.; El-Nahass, M. M.

    2015-09-01

    Ga5Se95 films were prepared by using thermal evaporation technique. X-ray showed that the powder samples as well as thin-film samples are crystalline in nature. The optical constants (refractive index n and rad absorption index k) of Ga5Se95 films were calculated using Murmann's exact method. The photoinduced red shift of the optical gap (photodarkening) appeared in Ga5Se95 films after illumination. The indirect energy gap was decreased from 1.75 eV for the as-deposited films to 1.65 eV for illuminated thin films 1 h. The concentration of color centers was calculated by using Gaussian fitting for peaks of the absorption coefficient ( α) and was found to increase from 5.6 × 1024 to 6.2 × 1024 cm-3 with illumination time. The effect of illumination on the nonlinear optical susceptibility ( χ (3)) and nonlinear refractive index ( n 2) is estimated using empirical relations.

  10. Effects of illuminants and illumination time on lettuce growth, yield and nutritional quality in a controlled environment

    Science.gov (United States)

    Shen, Y. Z.; Guo, S. S.; Ai, W. D.; Tang, Y. K.

    2014-07-01

    Effects of illuminants and illumination time on the growth of lettuce were researched. Red-blue light-emitting diodes (LEDs, 90% red light +10% blue light) and white light fluorescent (WF) lamps were compared as the illuminants for plant cultivation. Under each type of illuminant, lettuce was grown at 4 illumination times: 12 h, 16 h, 20 h and 24 h, with the same light intensity of 600 μmolm-2s-1. The leaf net photosynthetic rate (Pn) under the two illuminants was comparable but the shape of lettuce was obviously affected by the illuminant. The WF lamps produced more compact plant, while red-blue LED resulted in less but longer leaves. However, the total leaf area was not significantly affected by the illuminant. The red-blue LED produced nearly same aboveground biomass with far less energy consumption relative to WF lamps. The underground biomass was lowered under red-blue LED in comparison with WF lamps. Red-blue LED could improve the nutritional quality of lettuce by increasing the concentration of soluble sugar and vitamin C (VC) and reducing the concentration of nitrate. Under each type of illuminant, longer illumination time resulted in higher Pn, more leaves and larger leaf area. The total chlorophyll concentration increased while the concentration ratio of chlorophyll a/b decreased with the extension of illumination time. Illumination time had highly significant positive correlation with biomass. Moreover, when total daily light input was kept the same, longer illumination time increased the biomass significantly as well. In addition, longer illumination time increased the concentration of crude fiber, soluble sugar and VC and reduced the concentration of nitrate. In summary, red-blue LEDs and 24 h illumination time were demonstrated to be more suitable for lettuce cultivation in the controlled environment.

  11. Robust Face Image Matching under Illumination Variations

    Directory of Open Access Journals (Sweden)

    Yang Chyuan-Huei Thomas

    2004-01-01

    Full Text Available Face image matching is an essential step for face recognition and face verification. It is difficult to achieve robust face matching under various image acquisition conditions. In this paper, a novel face image matching algorithm robust against illumination variations is proposed. The proposed image matching algorithm is motivated by the characteristics of high image gradient along the face contours. We define a new consistency measure as the inner product between two normalized gradient vectors at the corresponding locations in two images. The normalized gradient is obtained by dividing the computed gradient vector by the corresponding locally maximal gradient magnitude. Then we compute the average consistency measures for all pairs of the corresponding face contour pixels to be the robust matching measure between two face images. To alleviate the problem due to shadow and intensity saturation, we introduce an intensity weighting function for each individual consistency measure to form a weighted average of the consistency measure. This robust consistency measure is further extended to integrate multiple face images of the same person captured under different illumination conditions, thus making our robust face matching algorithm. Experimental results of applying the proposed face image matching algorithm on some well-known face datasets are given in comparison with some existing face recognition methods. The results show that the proposed algorithm consistently outperforms other methods and achieves higher than 93% recognition rate with three reference images for different datasets under different lighting conditions.

  12. Surface color perception and equivalent illumination models.

    Science.gov (United States)

    Brainard, David H; Maloney, Laurence T

    2011-05-02

    Vision provides information about the properties and identity of objects. The ease with which we perceive object properties belies the difficulty of the underlying information-processing task. In the case of object color, retinal information about object reflectance is confounded with information about the illumination as well as about the object's shape and pose. There is no obvious rule that allows transformation of the retinal image to a color representation that depends primarily on object surface reflectance. Under many circumstances, however, object color appearance is remarkably stable across scenes in which the object is viewed. Here, we review a line of experiments and theory that aim to understand how the visual system stabilizes object color appearance. Our emphasis is on models derived from explicit analysis of the computational problem of estimating the physical properties of illuminants and surfaces from the retinal image, and experiments that test these models. We argue that this approach has considerable promise for allowing generalization from simplified laboratory experiments to richer scenes that more closely approximate natural viewing. We discuss the relation between the work we review and other theoretical approaches available in the literature.

  13. Development of constant-power driving control for light-emitting-diode (LED) luminaire

    KAUST Repository

    Huang, Bin-Juine

    2013-01-01

    The illumination of an LED may be affected by operating temperature even under constant-current condition. A constant-power driving technique is proposed in the present study for LED luminaire. A linear system dynamics model of LED luminaire is first derived and used in the design of the feedback control system. The PI controller was designed and tuned taking into account the control accuracy and robust properties with respect to plant uncertainty and variation of operating conditions. The control system was implemented on a microprocessor and used to control a 150W LED luminaire. The test result shows that the feedback system accurately controls the input power of LED luminaire to within 1.3 per cent error. As the ambient temperature changes from 0 to 40 °C, the LED illumination varies slightly (-1.7%) for constant-power driving, as compared to that of constant-current driving (-12%) and constant-voltage driving (+50%). The constant-power driving has revealed advantage in stabilizing the illumination of LED under large temperature variation. © 2012 Elsevier Ltd. All rights reserved.

  14. Illuminating Asset Value through New Seismic Technology

    Science.gov (United States)

    Brandsberg-Dahl, S.

    2007-05-01

    The ability to reduce risk and uncertainty across the full life cycle of an asset is directly correlated to creating an accurate subsurface image that enhances our understanding of the geology. This presentation focuses on this objective in areas of complex overburden in deepwater. Marine 3D seismic surveys have been acquired in essentially the same way for the past decade. This configuration of towed streamer acquisition, where the boat acquires data in one azimuth has been very effective in imaging areas in fairly benign geologic settings. As the industry has moved into more complicated geologic settings these surveys no longer meet the imaging objectives for risk reduction in exploration through production. In shallow water, we have seen increasing use of ocean bottom cables to meet this challenge. For deepwater, new breakthroughs in technology were required. This will be highlighted through examples of imaging below large salt bodies in the deep water Gulf of Mexico. GoM - Mad Dog: The Mad Dog field is located approximately 140 miles south of the Louisiana coastline in the southern Green Canyon area in water depths between 4100 feet to 6000 feet. The complex salt canopy overlying a large portion of the field results in generally poor seismic data quality. Advanced processing techniques improved the image, but gaps still remained even after several years of effort. We concluded that wide azimuth acquisition was required to illuminate the field in a new way. Results from the Wide Azimuth Towed Streamer (WATS) survey deployed at Mad Dog demonstrated the anticipated improvement in the subsalt image. GoM - Atlantis Field: An alternative approach to wide azimuth acquisition, ocean bottom seismic (OBS) node technology, was developed and tested. In 2001 deepwater practical experience was limited to a few nodes owned by academic institutions and there were no commercial solutions either available or in development. BP embarked on a program of sea trials designed to both

  15. Measurable values, numbers and fundamental physical constants: Is the Boltzmann constant Kb a fundamental physical constant?

    Directory of Open Access Journals (Sweden)

    Bormashenko Edward

    2009-01-01

    Full Text Available The status of fundamental physical constants is discussed. The nature of fundamental physical constants is cleared up, based on the analysis of the Boltzmann constant. A new definition of measurable values, 'mathematical' and 'physical' numbers and fundamental physical constants is proposed. Mathematical numbers are defined as values insensitive to the choice of both units and frames of reference, whereas 'physical numbers' are dimensionless values, insensitive to transformations of units and sensitive to the transformations of the frames of reference. Fundamental constants are classified as values sensitive to transformations of the units and insensitive to transformations of the frames of reference. It is supposed that a fundamental physical constant necessarily allows diminishing the number of independent etalons in a system of units.

  16. Spectrophotometric determination of association constant

    DEFF Research Database (Denmark)

    2016-01-01

    Least-squares 'Systematic Trial-and-Error Procedure' (STEP) for spectrophotometric evaluation of association constant (equilibrium constant) K and molar absorption coefficient E for a 1:1 molecular complex, A + B = C, with error analysis according to Conrow et al. (1964). An analysis of the Charg...

  17. Constant-Pressure Hydraulic Pump

    Science.gov (United States)

    Galloway, C. W.

    1982-01-01

    Constant output pressure in gas-driven hydraulic pump would be assured in new design for gas-to-hydraulic power converter. With a force-multiplying ring attached to gas piston, expanding gas would apply constant force on hydraulic piston even though gas pressure drops. As a result, pressure of hydraulic fluid remains steady, and power output of the pump does not vary.

  18. Spectrophotometric determination of association constant

    DEFF Research Database (Denmark)

    Spanget-Larsen, Jens

    2016-01-01

    Least-squares 'Systematic Trial-and-Error Procedure' (STEP) for spectrophotometric evaluation of association constant (equilibrium constant) K and molar absorption coefficient E for a 1:1 molecular complex, A + B = C, with error analysis according to Conrow et al. (1964). An analysis of the Charge...

  19. Face Detection under Complex Background and Illumination

    Institute of Scientific and Technical Information of China (English)

    Shao-Dong Lv; Yong-Duan Song; Mei Xu; Cong-Ying Huang

    2015-01-01

    Abstract⎯For face detection under complex background and illumination, a detection method that combines the skin color segmentation and cost-sensitive Adaboost algorithm is proposed in this paper. First, by using the characteristic of human skin color clustering in the color space, the skin color area inYCbCr color space is extracted and a large number of irrelevant backgrounds are excluded; then for remedyingthe deficiencies of Adaboost algorithm, the cost-sensitive function is introduced into the Adaboost algorithm; finally the skin color segmentation and cost-sensitive Adaboost algorithm are combined for the face detection. Experimental results show that the proposed detection method has a higher detection rate and detection speed, which can more adapt to the actual field environment.

  20. Color Data Compensation for Illumination Change

    Institute of Scientific and Technical Information of China (English)

    Pranchalee Rattanasakornchai; Yasushi Hoshino; Chun Weilin

    2004-01-01

    Compensation method for illumination change, which has big influences on the characteristics of imaging system, is studied. On the condition that color chart is placed in the view of camera, the imaging system recognizes the color chart and the signals from the camera are processed by using the color chart data. Concerning the light from the window, and fluorescent light, it is confirmed that color chart is possible to be recognized and the color system is corrected to the expected chart signal within the error 10 % by considering quadratic terms of RGB. This method is considered to improve the accuracy of motion detection and also to better video communication by realizing preferalle color reproduction.

  1. Uniform LED illuminator for miniature displays

    Science.gov (United States)

    Medvedev, Vladimir; Pelka, David G.; Parkyn, William A.

    1998-10-01

    The Total Internally Reflecting (TIR) lens is a faceted structure composed of prismatic elements that collect a source's light over a much larger angular range than a conventional Fresnel lens. It has been successfully applied to the efficient collimation of light from incandescent and fluorescent lamps, and from light-emitting diodes (LEDs). A novel LED-powered collimating backlight is presented here, for uniformly illuminating 0.25'-diagonal miniature liquid- crystal displays, which are a burgeoning market for pagers, cellular phones, digital cameras, camcorders, and virtual- reality displays. The backlight lens consists of a central dual-asphere refracting section and an outer TIR section, properly curved with a curved exit face.

  2. Multiple Illuminant Colour Estimation via Statistical Inference on Factor Graphs.

    Science.gov (United States)

    Mutimbu, Lawrence; Robles-Kelly, Antonio

    2016-08-31

    This paper presents a method to recover a spatially varying illuminant colour estimate from scenes lit by multiple light sources. Starting with the image formation process, we formulate the illuminant recovery problem in a statistically datadriven setting. To do this, we use a factor graph defined across the scale space of the input image. In the graph, we utilise a set of illuminant prototypes computed using a data driven approach. As a result, our method delivers a pixelwise illuminant colour estimate being devoid of libraries or user input. The use of a factor graph also allows for the illuminant estimates to be recovered making use of a maximum a posteriori (MAP) inference process. Moreover, we compute the probability marginals by performing a Delaunay triangulation on our factor graph. We illustrate the utility of our method for pixelwise illuminant colour recovery on widely available datasets and compare against a number of alternatives. We also show sample colour correction results on real-world images.

  3. Design of 25-inch Direct Illumination-type LED Backlight

    Institute of Scientific and Technical Information of China (English)

    LIANG Bao-wen; LI Rong-yu; GUO Ying-ying; WANG Shuai; CHEN Xiu-jin

    2008-01-01

    We utilized "direct illumination-type" LED backlight project, made white-light LED array in rectangle, designed a sheet of reflective film, a sheet of diffuser and two sheets of brightness enhancement film, then analyzed illuminance chart which was the result of simulation in several distance between reflective film and optical film. It showed the best matching between illuminance and uniformity while in 25 mm distance. Finally, we discussed some problems with thermal dispersion.

  4. Alternative Monte Carlo Approach for General Global Illumination

    Institute of Scientific and Technical Information of China (English)

    徐庆; 李朋; 徐源; 孙济洲

    2004-01-01

    An alternative Monte Carlo strategy for the computation of global illumination problem was presented.The proposed approach provided a new and optimal way for solving Monte Carlo global illumination based on the zero variance importance sampling procedure. A new importance driven Monte Carlo global illumination algorithm in the framework of the new computing scheme was developed and implemented. Results, which were obtained by rendering test scenes, show that this new framework and the newly derived algorithm are effective and promising.

  5. Energy efficient LED layout optimization for near-uniform illumination

    Science.gov (United States)

    Ali, Ramy E.; Elgala, Hany

    2016-09-01

    In this paper, we consider the problem of designing energy efficient light emitting diodes (LEDs) layout while satisfying the illumination constraints. Towards this objective, we present a simple approach to the illumination design problem based on the concept of the virtual LED. We formulate a constrained optimization problem for minimizing the power consumption while maintaining a near-uniform illumination throughout the room. By solving the resulting constrained linear program, we obtain the number of required LEDs and the optimal output luminous intensities that achieve the desired illumination constraints.

  6. Improving visibility in photoacoustic imaging using dynamic speckle illumination

    CERN Document Server

    Gateau, Jérôme; Katz, Ori; Gigan, Sylvain; Bossy, Emmanuel

    2013-01-01

    In high-frequency photoacoustic imaging with uniform illumination, homogenous photo-absorbing structures may be invisible because of their large size or limited-view issues. Here we show that it is possible to reveal features, which are normally invisible with a photoacoustic system comprised of a 20MHz linear ultrasound array, by exploiting dynamic speckle illumination. We demonstrate imaging of a \\emptyset 5mm absorbing cylinder and a 30 \\mu m black thread arranged in a complex shape. The hidden structures are directly retrieved from photoacoustic images recorded for different random speckle illuminations of the phantoms by assessing the variation in the value of each pixel over the illumination patterns.

  7. GaAs/Ge solar cell AC parameters under illumination

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, R.A.; Suresh, M.S. [ISRO Satellite Center, Bangalore (India); Nagaraju, J. [Indian Institute of Science, Bangalore (India). Department of Instrumentation, Solar Energy Laboratory

    2004-04-01

    The ac parameters of GaAs/Ge solar cell were measured under illumination at different cell temperatures using impedance spectroscopy technique. They are compared with the dark measurements. It is found that the cell capacitance is higher and cell resistance is lower under illumination than in dark for all cell terminal voltages. The cell capacitances at the corresponding maximum power point voltage (terminal) do not vary with temperature where as the cell resistance decreases. The cell capacitance under illumination is estimated from the dark cell capacitance and it is in good agreement with the measured illumination data. (author)

  8. Estimating Illumination Parameters Using Spherical Harmonics Coefficients in Frequency Space

    Institute of Scientific and Technical Information of China (English)

    XIE Feng; TAO Linmi; XU Guangyou

    2007-01-01

    An algorithm is presented for estimating the direction and strength of point light with the strength of ambient illumination. Existing approaches evaluate these illumination parameters directly in the high dimensional image space, while we estimate the parameters in two steps:first by projecting the image to an orthogonal linear subspace based on spherical harmonic basis functions and then by calculating the parameters in the low dimensional subspace.The test results using the CMU PIE database and Yale Database B show the stability and effectiveness of the method.The resulting illumination information can be used to synthesize more realistic relighting images and to recognize objects under variable illumination.

  9. An Active Illumination and Appearance (AIA) Model for Face Alignment

    DEFF Research Database (Denmark)

    Kahraman, Fatih; Gokmen, Muhittin; Darkner, Sune

    2007-01-01

    Face recognition systems are typically required to work under highly varying illumination conditions. This leads to complex effects imposed on the acquired face image that pertains little to the actual identity. Consequently, illumination normalization is required to reach acceptable recognition...... rates in face recognition systems. In this paper, we propose an approach that integrates the face identity and illumination models under the widely used Active Appearance Model framework as an extension to the texture model in order to obtain illumination-invariant face localization...

  10. Illuminance and luminance distributions of a prototype ambient illumination system for Space Station Freedom

    Science.gov (United States)

    Mullican, R. C.; Hayes, B. C.

    1991-01-01

    Preliminary results of research conducted in the late 1970's indicate that perceptual qualities of an enclosure can be influenced by the distribution of illumination within the enclosure. Subjective impressions such as spaciousness, perceptual clarity, and relaxation or tenseness, among others, appear to be related to different combinations of surface luminance. A prototype indirect ambient illumination system was developed which will allow crew members to alter surface luminance distributions within an enclosed module, thus modifying perceptual cues to match crew preferences. A traditional lensed direct lighting system was compared to the prototype utilizing the full-scale mockup of Space Station Freedom developed by Marshall Space Flight Center. The direct lensed system was installed in the habitation module with the indirect prototype deployed in the U.S. laboratory module. Analysis centered on the illuminance and luminance distributions resultant from these systems and the implications of various luminaire spacing options. All test configurations were evaluated for compliance with NASA Standard 3000, Man-System Integration Standards.

  11. DETERMINATION OF STABILITY CONSTANTS OF MANGANESE (II ...

    African Journals Online (AJOL)

    DR. AMINU

    Keywords: Amino acids, dissociation constant, potentiometry, stability constant. INTRODUCTION ... constants of manganese (II) amino acid complexes using potentiometer. .... Principles of Biochemistry Third Edition,. Worth publishers, 41 ...

  12. Varying constants, Gravitation and Cosmology

    CERN Document Server

    Uzan, Jean-Philippe

    2010-01-01

    Fundamental constants are a cornerstone of our physical laws. Any constant varying in space and/or time would reflect the existence of an almost massless field that couples to matter. This will induce a violation of the universality of free fall. It is thus of utmost importance for our understanding of gravity and of the domain of validity of general relativity to test for their constancy. We thus detail the relations between the constants, the tests of the local position invariance and of the universality of free fall. We then review the main experimental and observational constraints that have been obtained from atomic clocks, the Oklo phenomenon, Solar system observations, meteorites dating, quasar absorption spectra, stellar physics, pulsar timing, the cosmic microwave background and big bang nucleosynthesis. At each step we describe the basics of each system, its dependence with respect to the constants, the known systematic effects and the most recent constraints that have been obtained. We then describ...

  13. Ruzsa's Constant on Additive Functions

    Institute of Scientific and Technical Information of China (English)

    Jin Hui FANG; Yong Gao CHEN

    2013-01-01

    A function f:N → R is called additive if f(mn) =f(m)+f(n) for all m,n with (m,n) =1.Let μ(x) =maxn≤x(f(n)-f(n + 1)) and v(x) =maxn≤x(f(n + 1)-f(n)).In 1979,Ruzsa proved that there exists a constant c such that for any additive function f,μ(x) ≤ cv(x2) + cf,where cf is a constant depending only on f.Denote by Raf the least such constant c.We call Raf Ruzsa's constant on additive functions.In this paper,we prove that Raf ≤ 20.

  14. Naturally Time Dependent Cosmological Constant

    CERN Document Server

    Gregori, A

    2004-01-01

    In the light of the proposal of hep-th/0207195, we discuss in detail the issue of the cosmological constant, explaining how can string theory naturally predict the value which is experimentally observed, without low-energy supersymmetry.

  15. "Enlivening and - Dividing": An Aporia of Illumination

    Directory of Open Access Journals (Sweden)

    Hans Christian Hönes

    2015-08-01

    Full Text Available Normal 0 false false false EN-US JA X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:Verdana;} In 1798, Karl August Böttiger paid a nocturnal visit to the Gallery of Antiques in Dresden, illuminating the statues with a torch. At first glance, this seems to be yet another example of a popular practice for visiting galleries c.1800. Illuminating the sculptures by torchlight was a popular means of enlivening the objects, set in motion by the light flickering on their surfaces. The collections were thus meant to become a place where cold, white stone comes to life, and where the beholder becomes part of a revived antiquity.This was precisely what Böttiger intended, too. But to him, the effect of the torchlight appeared to be, as he wrote, “enlivening and – dividing!” The torchlight highlighted not only the beauty of the sculptures but also their modern restorations. Böttiger apparently failed to experience the living presence of the antique celebrated by many of his contemporaries (e.g. Goethe, Moritz.This essay focuses on the consequence of such a perception of sculptures as historically multi-layered objects. Böttiger’s experience resulted in a problematic situation. In trying to view the sculptures as contemporaries, he hoped to become ancient himself. But this operation failed in the moment when the sculptures themselves appeared to be anachronistic, impure palimpsests. In consequence, galleries may not only be the place were art history as chronological Stilgeschichte was born. They may also be the site where this perception changed into the experience of a more chaotic shape of time.

  16. Low-Cost Illumination-Grade LEDs

    Energy Technology Data Exchange (ETDEWEB)

    Epler, John [Philips Lumileds Lighting Company LLC, San Jose, CA (United States)

    2013-08-31

    Solid State Lighting is a cost-effective, energy-conserving technology serving a rapidly expand- ing multi-billion dollar market. This program was designed to accelerate this lighting revolution by reducing the manufacturing cost of Illumination-Grade LEDs. The technical strategy was to investigate growth substrate alternatives to standard planar sapphire, select the most effective and compatible option, and demonstrate a significant increase in Lumen/$ with a marketable LED. The most obvious alternate substrate, silicon, was extensively studied in the first two years of the program. The superior thermal and mechanical properties of Si were expected to improve wavelength uniformity and hence color yield in the manufacture of high-power illumination- grade LEDs. However, improvements in efficiency and epitaxy uniformity on standard c-plane sapphire diminished the advantages of switching to Si. Furthermore, the cost of sapphire decreased significantly and the cost of processing Si devices using our thin film process was higher than expected. We concluded that GaN on Si was a viable technology but not a practical option for Philips Lumileds. Therefore in 2012 and 2013, we sought and received amendments which broadened the scope to include other substrates and extended the time of execution. Proprietary engineered substrates, off-axis (non-c-plane) sapphire, and c-plane patterned sapphire substrates (PSS) were all investigated in the final 18 months of this program. Excellent epitaxy quality was achieved on all three candidates; however we eliminated engineered substrates and non-c-plane sapphire because of their higher combined cost of substrate, device fabrication and packaging. Ultimately, by fabricating a flip-chip (FC) LED based upon c-plane PSS we attained a 42% reduction in LED manufacturing cost relative to our LUXEON Rebel product (Q1-2012). Combined with a flux gain from 85 to 102 Lm, the LUXEON Q delivered a 210% increase in Lm/$ over this time period. The

  17. Inflation and the cosmological constant

    Directory of Open Access Journals (Sweden)

    FENG Chaojun

    2014-08-01

    Full Text Available By assuming the cosmological “constant” is no longer a constant during the inflation epoch,it is found that the cosmological constant fine-tuning problem is solved.In the meanwhile,inflation models could predict a large tensor-to-scalar ratio,correct power spectral index and a larger running of it.Furthermore,the e-folding number is large enough to overcome the horizon,flatness problems in the Big Bang cosmology.

  18. Varying Constants, Gravitation and Cosmology

    Directory of Open Access Journals (Sweden)

    Jean-Philippe Uzan

    2011-03-01

    Full Text Available Fundamental constants are a cornerstone of our physical laws. Any constant varying in space and/or time would reflect the existence of an almost massless field that couples to matter. This will induce a violation of the universality of free fall. Thus, it is of utmost importance for our understanding of gravity and of the domain of validity of general relativity to test for their constancy. We detail the relations between the constants, the tests of the local position invariance and of the universality of free fall. We then review the main experimental and observational constraints that have been obtained from atomic clocks, the Oklo phenomenon, solar system observations, meteorite dating, quasar absorption spectra, stellar physics, pulsar timing, the cosmic microwave background and big bang nucleosynthesis. At each step we describe the basics of each system, its dependence with respect to the constants, the known systematic effects and the most recent constraints that have been obtained. We then describe the main theoretical frameworks in which the low-energy constants may actually be varying and we focus on the unification mechanisms and the relations between the variation of different constants. To finish, we discuss the more speculative possibility of understanding their numerical values and the apparent fine-tuning that they confront us with.

  19. Varying Constants, Gravitation and Cosmology.

    Science.gov (United States)

    Uzan, Jean-Philippe

    2011-01-01

    Fundamental constants are a cornerstone of our physical laws. Any constant varying in space and/or time would reflect the existence of an almost massless field that couples to matter. This will induce a violation of the universality of free fall. Thus, it is of utmost importance for our understanding of gravity and of the domain of validity of general relativity to test for their constancy. We detail the relations between the constants, the tests of the local position invariance and of the universality of free fall. We then review the main experimental and observational constraints that have been obtained from atomic clocks, the Oklo phenomenon, solar system observations, meteorite dating, quasar absorption spectra, stellar physics, pulsar timing, the cosmic microwave background and big bang nucleosynthesis. At each step we describe the basics of each system, its dependence with respect to the constants, the known systematic effects and the most recent constraints that have been obtained. We then describe the main theoretical frameworks in which the low-energy constants may actually be varying and we focus on the unification mechanisms and the relations between the variation of different constants. To finish, we discuss the more speculative possibility of understanding their numerical values and the apparent fine-tuning that they confront us with.

  20. Varying Constants, Gravitation and Cosmology

    Science.gov (United States)

    Uzan, Jean-Philippe

    2011-12-01

    Fundamental constants are a cornerstone of our physical laws. Any constant varying in space and/or time would reflect the existence of an almost massless field that couples to matter. This will induce a violation of the universality of free fall. Thus, it is of utmost importance for our understanding of gravity and of the domain of validity of general relativity to test for their constancy. We detail the relations between the constants, the tests of the local position invariance and of the universality of free fall. We then review the main experimental and observational constraints that have been obtained from atomic clocks, the Oklo phenomenon, solar system observations, meteorite dating, quasar absorption spectra, stellar physics, pulsar timing, the cosmic microwave background and big bang nucleosynthesis. At each step we describe the basics of each system, its dependence with respect to the constants, the known systematic effects and the most recent constraints that have been obtained. We then describe the main theoretical frameworks in which the low-energy constants may actually be varying and we focus on the unification mechanisms and the relations between the variation of different constants. To finish, we discuss the more speculative possibility of understanding their numerical values and the apparent fine-tuning that they confront us with.

  1. Photoinduced Giant Dielectric Constant in Lead Halide Perovskite Solar Cells.

    Science.gov (United States)

    Juarez-Perez, Emilio J; Sanchez, Rafael S; Badia, Laura; Garcia-Belmonte, Germá; Kang, Yong Soo; Mora-Sero, Ivan; Bisquert, Juan

    2014-07-03

    Organic-inorganic lead trihalide perovskites have emerged as an outstanding photovoltaic material that demonstrated a high 17.9% conversion efficiency of sunlight to electricity in a short time. We have found a giant dielectric constant (GDC) phenomenon in these materials consisting on a low frequency dielectric constant in the dark of the order of ε0 = 1000. We also found an unprecedented behavior in which ε0 further increases under illumination or by charge injection at applied bias. We observe that ε0 increases nearly linearly with the illumination intensity up to an additional factor 1000 under 1 sun. Measurement of a variety of samples of different morphologies, compositions, and different types of contacts shows that the GDC is an intrinsic property of MAPbX3 (MA = CH3NH3(+)). We hypothesize that the large dielectric response is induced by structural fluctuations. Photoinduced carriers modify the local unit cell equilibrium and change the polarizability, assisted by the freedom of rotation of MA. The study opens a way for the understanding of a key aspect of the photovoltaic operation of high efficiency perovskite solar cells.

  2. Illumination-invariant hand gesture recognition

    Science.gov (United States)

    Mendoza-Morales, América I.; Miramontes-Jaramillo, Daniel; Kober, Vitaly

    2015-09-01

    In recent years, human-computer interaction (HCI) has received a lot of interest in industry and science because it provides new ways to interact with modern devices through voice, body, and facial/hand gestures. The application range of the HCI is from easy control of home appliances to entertainment. Hand gesture recognition is a particularly interesting problem because the shape and movement of hands usually are complex and flexible to be able to codify many different signs. In this work we propose a three step algorithm: first, detection of hands in the current frame is carried out; second, hand tracking across the video sequence is performed; finally, robust recognition of gestures across subsequent frames is made. Recognition rate highly depends on non-uniform illumination of the scene and occlusion of hands. In order to overcome these issues we use two Microsoft Kinect devices utilizing combined information from RGB and infrared sensors. The algorithm performance is tested in terms of recognition rate and processing time.

  3. Combining Illumination Normalization Methods for Better Face Recognition

    NARCIS (Netherlands)

    Boom, B.J.; Tao, Q.; Spreeuwers, L.J.; Veldhuis, R.N.J.

    2009-01-01

    Face Recognition under uncontrolled illumination conditions is partly an unsolved problem. There are two categories of illumination normalization methods. The first category performs a local preprocessing, where they correct a pixel value based on a local neighborhood in the images. The second categ

  4. 46 CFR 112.43-11 - Illumination for launching operations.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Illumination for launching operations. 112.43-11 Section 112.43-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Lighting Systems § 112.43-11 Illumination for...

  5. Köhler illumination in high-resolution optical metrology

    Science.gov (United States)

    Sohn, Yeung Joon; Barnes, Brian M.; Howard, Lowell; Silver, Richard M.; Attota, Ravikiran; Stocker, Michael T.

    2006-03-01

    Accurate preparation of illumination is critical for high-resolution optical metrology applications such as linewidth and overlay measurements. To improve the detailed evaluation and alignment of the illumination optics, we have separated Koehler illumination into three components. The three Koehler illumination components are defined as full field spatial intensity variation (Koehler factor 1), angular intensity homogeneity (Koehler factor 2), and wavefront phase/intensity homogeneity (Koehler factor 3). We have also proposed a field aperture pattern transfer method to analyze the illumination properties with respect to systematic variations, such as the shape of the source, the intensity distribution at the back focal plane, and the displacements of elements along and off the optical axis. These factors were investigated in both ideal and practical illumination systems. In particular, any angular asymmetry in the illumination proves to have a detrimental effect upon the distribution of light that illuminates the target. Wavefront asymmetry is also studied in the context of an optical system with a coherent or partially coherent light source.

  6. Future illumination systems and the climate change challenge

    DEFF Research Database (Denmark)

    Bjarklev, Araceli; Bjarklev, Anders Overgaard

    2010-01-01

    LED technology will be part of the development, but hybrid illumination systems can also play an important role for the future illumination systems in the tertiary sector in the future. From the ecodesign perspective, the study points out that some of the major technological and economic challenges...

  7. Transfer between Pose and Illumination Training in Face Recognition

    Science.gov (United States)

    Liu, Chang Hong; Bhuiyan, Md. Al-Amin; Ward, James; Sui, Jie

    2009-01-01

    The relationship between pose and illumination learning in face recognition was examined in a yes-no recognition paradigm. The authors assessed whether pose training can transfer to a new illumination or vice versa. Results show that an extensive level of pose training through a face-name association task was able to generalize to a new…

  8. Learning Read-constant Polynomials of Constant Degree modulo Composites

    DEFF Research Database (Denmark)

    Chattopadhyay, Arkadev; Gavaldá, Richard; Hansen, Kristoffer Arnsfelt;

    2011-01-01

    Boolean functions that have constant degree polynomial representation over a fixed finite ring form a natural and strict subclass of the complexity class \\textACC0ACC0. They are also precisely the functions computable efficiently by programs over fixed and finite nilpotent groups. This class...... is not known to be learnable in any reasonable learning model. In this paper, we provide a deterministic polynomial time algorithm for learning Boolean functions represented by polynomials of constant degree over arbitrary finite rings from membership queries, with the additional constraint that each variable...

  9. Effective cosmological constant induced by stochastic fluctuations of Newton's constant

    Science.gov (United States)

    de Cesare, Marco; Lizzi, Fedele; Sakellariadou, Mairi

    2016-09-01

    We consider implications of the microscopic dynamics of spacetime for the evolution of cosmological models. We argue that quantum geometry effects may lead to stochastic fluctuations of the gravitational constant, which is thus considered as a macroscopic effective dynamical quantity. Consistency with Riemannian geometry entails the presence of a time-dependent dark energy term in the modified field equations, which can be expressed in terms of the dynamical gravitational constant. We suggest that the late-time accelerated expansion of the Universe may be ascribed to quantum fluctuations in the geometry of spacetime rather than the vacuum energy from the matter sector.

  10. Effective cosmological constant induced by stochastic fluctuations of Newton's constant

    CERN Document Server

    de Cesare, Marco; Sakellariadou, Mairi

    2016-01-01

    We consider implications of the microscopic dynamics of spacetime for the evolution of cosmological models. We argue that quantum geometry effects may lead to stochastic fluctuations of the gravitational constant, which is thus considered as a macroscopic effective dynamical quantity. Consistency with Riemannian geometry entails the presence of a time-dependent dark energy term in the modified field equations, which can be expressed in terms of the dynamical gravitational constant. We suggest that the late-time accelerated expansion of the Universe may be ascribed to quantum fluctuations in the geometry of spacetime rather than the vacuum energy from the matter sector.

  11. Evaluation of retinal illumination in coaxial fundus camera

    Science.gov (United States)

    de Oliveira, André O.; de Matos, Luciana; Castro Neto, Jarbas C.

    2016-09-01

    Retinal images are obtained by simultaneously illuminating and imaging the retina, which is achieved using a fundus camera. This device meets low light illumination of the fundus with high resolution and reflection free images. Although the current equipment presents a sophisticated solution, it is complex to align due to the high number of off-axis components. In this work, we substitute the complex illumination system by a ring of LEDs mounted coaxially to the imaging optical system, positioning it in the place of the holed mirror of the traditional optical design. We evaluated the impact of this substitution regarding to image quality (measured through the modulation transfer function) and illumination uniformity produced by this system on the retina. The results showed there is no change in image quality and no problem was detected concerning uniformity compared to the traditional equipment. Consequently, we avoided off-axis components, easing the alignment of the equipment without reducing both image quality and illumination uniformity.

  12. Standard specification for illuminators used for viewing industrial radiographs

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 The function of the illuminator is to provide sufficient illumination and viewing capabilities for the purpose of identification and interpretation of radiographic images. This specification provides the recommended minimum requirements for Industrial Radiographic Illuminators used for viewing industrial radiographic films using transmitted light sources. 1.2 The illuminator has to ensure the same safety for personnel, or users of any electric apparatus, as specified by electrical standards applicable in the country in which the illuminator is used. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.3 Values stated in SI units are to be regarded as the standard. The values given in parenthesis are provided for information only.

  13. A wearable infrared video pupillography with multi-stimulation of consistent illumination for binocular pupil response

    Science.gov (United States)

    Mang, Ou-Yang; Ko, Mei Lan; Tsai, Yi-Chun; Chiou, Jin-Chern; Huang, Ting-Wei

    2016-03-01

    The pupil response to light can reflect various kinds of diseases which are related to physiological health. Pupillary abnormalities may be influenced on people by autonomic neuropathy, glaucoma, diabetes, genetic diseases, and high myopia. In the early stage of neuropathy, it is often asymptomatic and difficulty detectable by ophthalmologists. In addition, the position of injured nerve can lead to unsynchronized pupil response for human eyes. In our study, we design the pupilometer to measure the binocular pupil response simultaneously. It uses the different wavelength of LEDs such as white, red, green and blue light to stimulate the pupil and record the process. Therefore, the pupilometer mainly contains two systems. One is the image acquisition system, it use the two cameras modules with the same external triggered signal to capture the images of the pupil simultaneously. The other one is the illumination system. It use the boost converter ICs and LED driver ICs to supply the constant current for LED to maintain the consistent luminance in each experiments for reduced experimental error. Furthermore, the four infrared LEDs are arranged nearby the stimulating LEDs to illuminate eyes and increase contrast of image for image processing. In our design, we success to implement the function of synchronized image acquisition with the sample speed in 30 fps and the stable illumination system for precise measurement of experiment.

  14. Image illumination enhancement with an objective no-reference measure of illumination assessment based on Gaussian distribution mapping

    Directory of Open Access Journals (Sweden)

    Gholamreza Anbarjafari

    2015-12-01

    Full Text Available Illumination problems have been an important concern in many image processing applications. The pattern of the histogram on an image introduces meaningful features; hence within the process of illumination enhancement, it is important not to destroy such information. In this paper we propose a method to enhance image illumination using Gaussian distribution mapping which also keeps the information laid on the pattern of the histogram on the original image. First a Gaussian distribution based on the mean and standard deviation of the input image will be calculated. Simultaneously a Gaussian distribution with the desired mean and standard deviation will be calculated. Then a cumulative distribution function of each of the Gaussian distributions will be calculated and used in order to map the old pixel value onto the new pixel value. Another important issue in the field of illumination enhancement is absence of a quantitative measure for the assessment of the illumination of an image. In this research work, a quantitative measure indicating the illumination state, i.e. contrast level and brightness of an image, is also proposed. The measure utilizes the estimated Gaussian distribution of the input image and the Kullback-Leibler Divergence (KLD between the estimated Gaussian and the desired Gaussian distributions to calculate the quantitative measure. The experimental results show the effectiveness and the reliability of the proposed illumination enhancement technique, as well as the proposed illumination assessment measure over conventional and state-of-the-art techniques.

  15. Illuminate Knowledge Elements in Geoscience Literature

    Science.gov (United States)

    Ma, X.; Zheng, J. G.; Wang, H.; Fox, P. A.

    2015-12-01

    There are numerous dark data hidden in geoscience literature. Efficient retrieval and reuse of those data will greatly benefit geoscience researches of nowadays. Among the works of data rescue, a topic of interest is illuminating the knowledge framework, i.e. entities and relationships, embedded in documents. Entity recognition and linking have received extensive attention in news and social media analysis, as well as in bioinformatics. In the domain of geoscience, however, such works are limited. We will present our work on how to use knowledge bases on the Web, such as ontologies and vocabularies, to facilitate entity recognition and linking in geoscience literature. The work deploys an un-supervised collective inference approach [1] to link entity mentions in unstructured texts to a knowledge base, which leverages the meaningful information and structures in ontologies and vocabularies for similarity computation and entity ranking. Our work is still in the initial stage towards the detection of knowledge frameworks in literature, and we have been collecting geoscience ontologies and vocabularies in order to build a comprehensive geoscience knowledge base [2]. We hope the work will initiate new ideas and collaborations on dark data rescue, as well as on the synthesis of data and knowledge from geoscience literature. References: 1. Zheng, J., Howsmon, D., Zhang, B., Hahn, J., McGuinness, D.L., Hendler, J., and Ji, H. 2014. Entity linking for biomedical literature. In Proceedings of ACM 8th International Workshop on Data and Text Mining in Bioinformatics, Shanghai, China. 2. Ma, X. Zheng, J., 2015. Linking geoscience entity mentions to the Web of Data. ESIP 2015 Summer Meeting, Pacific Grove, CA.

  16. From the Rydberg constant to the fundamental constants metrology; De la constante de Rydberg a la metrologie des constantes fondamentales

    Energy Technology Data Exchange (ETDEWEB)

    Nez, F

    2005-06-15

    This document reviews the theoretical and experimental achievements of the author since the beginning of his scientific career. This document is dedicated to the spectroscopy of hydrogen, deuterium and helium atoms. The first part is divided into 6 sub-sections: 1) the principles of hydrogen spectroscopy, 2) the measurement of the 2S-nS/nD transitions, 3) other optical frequency measurements, 4) our contribution to the determination of the Rydberg constant, 5) our current experiment on the 1S-3S transition, 6) the spectroscopy of the muonic hydrogen. Our experiments have improved the accuracy of the Rydberg Constant by a factor 25 in 15 years and we have achieved the first absolute optical frequency measurement of a transition in hydrogen. The second part is dedicated to the measurement of the fine structure constant and the last part deals with helium spectroscopy and the search for optical references in the near infrared range. (A.C.)

  17. Mirror QCD and Cosmological Constant

    CERN Document Server

    Pasechnik, Roman; Teryaev, Oleg

    2016-01-01

    An analog of Quantum Chromo Dynamics (QCD) sector known as mirror QCD (mQCD) can affect the cosmological evolution and help in resolving the Cosmological Constant problem. In this work, we explore an intriguing possibility for a compensation of the negative QCD vacuum contribution to the ground state energy density of the universe by means of a positive contribution from the chromomagnetic gluon condensate in mQCD. The trace anomaly compensation condition and the form of the mQCD coupling constant in the infrared limit have been proposed by analysing a partial non-perturbative solution of the Einstein--Yang-Mills equations of motion.

  18. Spatial Variations of Fundamental Constants

    CERN Document Server

    Barrow, John D; Barrow, John D.; Toole, Chris O'

    1999-01-01

    We show that observational limits on the possible time variation of constants of Nature are significantly affected by allowing for both space and time variation. Bekenstein's generalisation of Maxwell's equations to allow for cosmological variation of $alpha$ is investigated in a universe containing spherically symmetric inhomogeneities. The time variation of $alpha$ is determined by the local matter density and hence limits obtained in high-density geophysical enviroments are far more constraining than those obtained at high redshift. This new feature is expected to be a property of a wide class of theories for the variation of constants.

  19. Bouncing universes with varying constants

    Energy Technology Data Exchange (ETDEWEB)

    Barrow, John D [DAMTP, Centre for Mathematical Sciences, Cambridge University, Wilberforce Road, Cambridge CB3 0WA (United Kingdom); Kimberly, Dagny [Theoretical Physics, Blackett Laboratory, Imperial College, Prince Consort Road, London SW7 2BZ (United Kingdom); Magueijo, Joao [Theoretical Physics, Blackett Laboratory, Imperial College, Prince Consort Road, London SW7 2BZ (United Kingdom)

    2004-09-21

    We investigate the behaviour of exact closed bouncing Friedmann universes in theories with varying constants. We show that the simplest BSBM varying alpha theory leads to a bouncing universe. The value of alpha increases monotonically, remaining approximately constant during most of each cycle, but increasing significantly around each bounce. When dissipation is introduced we show that in each new cycle the universe expands for longer and to a larger size. We find a similar effect for closed bouncing universes in Brans-Dicke theory, where G also varies monotonically in time from cycle to cycle. Similar behaviour occurs also in varying speed of light theories.

  20. Bouncing Universes with Varying Constants

    CERN Document Server

    Barrow, J D; Magueijo, J; Barrow, John D.; Kimberly, Dagny; Magueijo, Joao

    2004-01-01

    We investigate the behaviour of exact closed bouncing Friedmann universes in theories with varying constants. We show that the simplest BSBM varying-alpha theory leads to a bouncing universe. The value of alpha increases monotonically, remaining approximately constant during most of each cycle, but increasing significantly around each bounce. When dissipation is introduced we show that in each new cycle the universe expands for longer and to a larger size. We find a similar effect for closed bouncing universes in Brans-Dicke theory, where $G$ also varies monotonically in time from cycle to cycle. Similar behaviour occurs also in varying speed of light theories.

  1. Gravitational Instantons and Cosmological Constant

    CERN Document Server

    Cyriac, Josily

    2015-01-01

    The cosmological dynamics of an otherwise empty universe in the presence of vacuum fields is considered. Quantum fluctuations at the Planck scale leads to a dynamical topology of space-time at very small length scales, which is dominated by compact gravitational instantons. The Planck scale vacuum energy acts as a source for the curvature of the these compact gravitational instantons and decouples from the large scale energy momentum tensor of the universe, thus making the observable cosmological constant vanish. However, a Euclidean functional integral over all possible topologies of the gravitational instantons generates a small non-zero value for the large scale cosmological constant, which agrees with the present observations.

  2. LRO-LAMP Observations of Illumination Conditions in the Lunar South Pole

    Science.gov (United States)

    Mandt, K.; Greathouse, T. K.; Retherford, K. D.; Mazarico, E.; Gladstone, R.; Liu, Y.; Hendrix, A.; Hurley, D.; Lemelin, M.; Patterson, G. W.; Bowman-Cisneros, E.

    2016-12-01

    The south pole of the Moon is an area of great interest for space exploration and scientific research, because many low-lying regions are permanently shaded while adjacent topographic highs experience near constant sunlight. The lack of direct sunlight in permanently shaded regions (PSRs) provides cold enough conditions for them to potentially trap and retain large quantities of volatiles in their soils, while the locations that receive extended periods of sunlight could provide a reliable source of solar energy and relatively stable temperature conditions. Illumination conditions at the lunar south pole vary diurnally and seasonally, but on different timescales than days and seasons on the Earth. The most important advancements in understanding illumination conditions at the poles are provided by topographic mapping and illumination modeling. These efforts have provided estimates of the extent of PSRs and the percent of time that sunlit peaks are illuminated. They also help to constrain the thermal balance of the PSRs based on other sources of illumination. However, comparing model results with spacecraft observations can help to validate the models and provides ground truth for planning future exploration efforts. We have developed a new method for observing illumination conditions at the south pole using data taken by the LRO Lyman Alpha Mapping Project (LAMP), a far ultraviolet (FUV) imaging spectrograph. LAMP produces maps of the albedo of the upper 25-100 nm of lunar regolith using measurements of the brightness of reflected light relative to known light sources in daytime and nighttime conditions. Nighttime observations have been used previously to determine the abundance of surface frost within the PSRs and the surface porosity of regolith within the PSRs. The maps that have been used for these studies excluded scattered sunlight by restricting observations to nighttime conditions when the solar zenith angle is greater than 91°. However, by producing maps

  3. Spectral image analysis of mutual illumination between florescent objects.

    Science.gov (United States)

    Tominaga, Shoji; Kato, Keiji; Hirai, Keita; Horiuchi, Takahiko

    2016-08-01

    This paper proposes a method for modeling and component estimation of the spectral images of the mutual illumination phenomenon between two fluorescent objects. First, we briefly describe the bispectral characteristics of a single fluorescent object, which are summarized as a Donaldson matrix. We suppose that two fluorescent objects with different bispectral characteristics are located close together under a uniform illumination. Second, we model the mutual illumination between two objects. It is shown that the spectral composition of the mutual illumination is summarized with four components: (1) diffuse reflection, (2) diffuse-diffuse interreflection, (3) fluorescent self-luminescence, and (4) interreflection by mutual fluorescent illumination. Third, we develop algorithms for estimating the spectral image components from the observed images influenced by the mutual illumination. When the exact Donaldson matrices caused by the mutual illumination influence are unknown, we have to solve a non-linear estimation problem to estimate both the spectral functions and the location weights. An iterative algorithm is then proposed to solve the problem based on the alternate estimation of the spectral functions and the location weights. In our experiments, the feasibility of the proposed method is shown in three cases: the known Donaldson matrices, weak interreflection, and strong interreflection.

  4. Quantitative photoacoustic tomography using illuminations from a single direction.

    Science.gov (United States)

    Pulkkinen, Aki; Cox, Ben T; Arridge, Simon R; Kaipio, Jari P; Tarvainen, Tanja

    2015-03-01

    Quantitative photoacoustic tomography is an emerging imaging technique aimed at estimating optical parameters inside tissues from photoacoustic images, which are formed by combining optical information and ultrasonic propagation. This optical parameter estimation problem is ill-posed and needs to be approached within the framework of inverse problems. It has been shown that, in general, estimating the spatial distribution of more than one optical parameter is a nonunique problem unless more than one illumination pattern is used. Generally, this is overcome by illuminating the target from various directions. However, in some cases, for example when thick samples are investigated, illuminating the target from different directions may not be possible. In this work, the use of spatially modulated illumination patterns at one side of the target is investigated with simulations. The results show that the spatially modulated illumination patterns from a single direction could be used to provide multiple illuminations for quantitative photoacoustic tomography. Furthermore, the results show that the approach can be used to distinguish absorption and scattering inclusions located near the surface of the target. However, when compared to a full multidirection illumination setup, the approach cannot be used to image as deep inside tissues.

  5. Photoactivation and optogenetics with micro mirror enhanced illumination

    Science.gov (United States)

    Rückerl, F.; Berndt, D.; Heber, J.; Shorte, S.

    2014-05-01

    Photoactivation and "optogenetics" require the precise control of the illumination path in optical microscopes. It is equally important to shape the illumination spatially as well as to have control over the intensity and the duration of the illumination. In order to achieve these goals we use programmable, diffractive Micro Mirror Arrays (MMA) as fast spatial light modulators for beam steering. By combining two MMAs with 256×256 mirrors each, our illumination setup allows for fast angular and spatial control at a wide spectral range (260-1000 nm). Illumination pulses can be as short as 50 μs, or can also extend to several seconds. The specific illumination modes of the individual areas results in a precise control over the light dose to the sample, giving significant advantage when investigating dosage dependent activation inasmuch as both the duration and the intensity can be controlled distinctly. The setup is integrated to a microscope and allows selective illumination of regions in the sample, enabling the precise, localized activation of fluorescent probes and the activation and deactivation of cellular and subcellular signaling cascades using photo activated ion channels. The high reflectivity in the UV range (up to 260nm) further allows gene silencing using UV activated constructs (e.g. caged morpholinos).

  6. Rock fracture image acquisition with both visible and ultraviolet illuminations

    Science.gov (United States)

    Wang, Weixing; Hakami, Eva

    2006-02-01

    Swedish Nuclear Fuel and Waste Management Company (SKB) have identified the need for a better understanding of radionuclide transport and retention processes in fractured rock since 1994. In the study, the first hard problem is to obtain rock fracture images of a good quality, since rock surface is very rough, and composed of complicated and multiple fractures, as a result, image acquisition is the first important. As a cooperation project between Sweden and China, we sampled a number of rock specimens for analyzing rock fracture network by visible and ultraviolet image technique, in the field. The samples are resin injected, in which way; opened fractures can be seen clearly by means of UV light illumination, and the rock surface information can be obtained by using visible optical illumination. We used different digital cameras and microscope to take images by two illuminations. From the same samples; we found that UV illumination image gives the clear information of fracture opening or closing, and the visible optical illumination gives the information of the rock surface (e.g. filling materials inside of fractures). By applying this technique, the minimum width of rock fracture 0.01 mm can be analyzed. This paper presents: (1) Rock fracture image acquiring techniques; (2) Rock fracture image acquisition by using UV light illumination and visible optical illumination; and (3) Conclusions. The studied method can be used both in the field and a laboratory.

  7. Decay Constants of Vector Mesons

    Institute of Scientific and Technical Information of China (English)

    LI Heng-Mei; WAN Shao-Long

    2008-01-01

    @@ The light vector mesons are studied within the framework of the Bethe-Salpeter equation with the vector-vectortype flat-bottom potential The Bethe-Salpeter wavefunctions and the decay constants of the vector mesons are obtained. All the obtained results, fρ, fφ, and fΚ* , are in agreement with the experimental values, respectively.

  8. Effects of chromatic image statistics on illumination induced color differences.

    Science.gov (United States)

    Lucassen, Marcel P; Gevers, Theo; Gijsenij, Arjan; Dekker, Niels

    2013-09-01

    We measure the color fidelity of visual scenes that are rendered under different (simulated) illuminants and shown on a calibrated LCD display. Observers make triad illuminant comparisons involving the renderings from two chromatic test illuminants and one achromatic reference illuminant shown simultaneously. Four chromatic test illuminants are used: two along the daylight locus (yellow and blue), and two perpendicular to it (red and green). The observers select the rendering having the best color fidelity, thereby indirectly judging which of the two test illuminants induces the smallest color differences compared to the reference. Both multicolor test scenes and natural scenes are studied. The multicolor scenes are synthesized and represent ellipsoidal distributions in CIELAB chromaticity space having the same mean chromaticity but different chromatic orientations. We show that, for those distributions, color fidelity is best when the vector of the illuminant change (pointing from neutral to chromatic) is parallel to the major axis of the scene's chromatic distribution. For our selection of natural scenes, which generally have much broader chromatic distributions, we measure a higher color fidelity for the yellow and blue illuminants than for red and green. Scrambled versions of the natural images are also studied to exclude possible semantic effects. We quantitatively predict the average observer response (i.e., the illuminant probability) with four types of models, differing in the extent to which they incorporate information processing by the visual system. Results show different levels of performance for the models, and different levels for the multicolor scenes and the natural scenes. Overall, models based on the scene averaged color difference have the best performance. We discuss how color constancy algorithms may be improved by exploiting knowledge of the chromatic distribution of the visual scene.

  9. The 1% concordance Hubble constant

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, C. L.; Larson, D.; Weiland, J. L. [Johns Hopkins University, 3400 North Charles Street, Baltimore, MD 21218 (United States); Hinshaw, G., E-mail: cbennett@jhu.edu [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC V6T 1Z1 (Canada)

    2014-10-20

    The determination of the Hubble constant has been a central goal in observational astrophysics for nearly a hundred years. Extraordinary progress has occurred in recent years on two fronts: the cosmic distance ladder measurements at low redshift and cosmic microwave background (CMB) measurements at high redshift. The CMB is used to predict the current expansion rate through a best-fit cosmological model. Complementary progress has been made with baryon acoustic oscillation (BAO) measurements at relatively low redshifts. While BAO data do not independently determine a Hubble constant, they are important for constraints on possible solutions and checks on cosmic consistency. A precise determination of the Hubble constant is of great value, but it is more important to compare the high and low redshift measurements to test our cosmological model. Significant tension would suggest either uncertainties not accounted for in the experimental estimates or the discovery of new physics beyond the standard model of cosmology. In this paper we examine in detail the tension between the CMB, BAO, and cosmic distance ladder data sets. We find that these measurements are consistent within reasonable statistical expectations and we combine them to determine a best-fit Hubble constant of 69.6 ± 0.7 km s{sup –1} Mpc{sup –1}. This value is based upon WMAP9+SPT+ACT+6dFGS+BOSS/DR11+H {sub 0}/Riess; we explore alternate data combinations in the text. The combined data constrain the Hubble constant to 1%, with no compelling evidence for new physics.

  10. Variation of fundamental constants: theory

    Science.gov (United States)

    Flambaum, Victor

    2008-05-01

    Theories unifying gravity with other interactions suggest temporal and spatial variation of the fundamental ``constants'' in expanding Universe. There are some hints for the variation of different fundamental constants in quasar absorption spectra and Big Bang nucleosynthesis data. A large number of publications (including atomic clocks) report limits on the variations. We want to study the variation of the main dimensionless parameters of the Standard Model: 1. Fine structure constant alpha (combination of speed of light, electron charge and Plank constant). 2. Ratio of the strong interaction scale (LambdaQCD) to a fundamental mass like electron mass or quark mass which are proportional to Higgs vacuum expectation value. The proton mass is propotional to LambdaQCD, therefore, the proton-to-electron mass ratio comes into this second category. We performed necessary atomic, nuclear and QCD calculations needed to study variation of the fundamental constants using the Big Bang Nucleosynthsis, quasar spectra, Oklo natural nuclear reactor and atomic clock data. The relative effects of the variation may be enhanced in transitions between narrow close levels in atoms, molecules and nuclei. If one will study an enhanced effect, the relative value of systematic effects (which are not enhanced) may be much smaller. Note also that the absolute magnitude of the variation effects in nuclei (e.g. in very narrow 7 eV transition in 229Th) may be 5 orders of magnitude larger than in atoms. A different possibility of enhancement comes from the inversion transitions in molecules where splitting between the levels is due to the quantum tunneling amplitude which has strong, exponential dependence on the electron to proton mass ratio. Our study of NH3 quasar spectra has already given the best limit on the variation of electron to proton mass ratio.

  11. Varying Fine-Structure Constant and the Cosmological Constant Problem

    CERN Document Server

    Fujii, Y

    2003-01-01

    We start with a brief account of the latest analysis of the Oklo phenomenon providing the still most stringent constraint on time-variability of the fine- structure constant $\\alpha$. Comparing this with the recent result from the measurement of distant QSO's appears to indicate a non-uniform time-dependence, which we argue to be related to another recent finding of the accelerating universe. This view is implemented in terms of the scalar-tensor theory, applied specifically to the small but nonzero cosmological constant. Our detailed calculation shows that these two phenomena can be understood in terms of a common origin, a particular behavior of the scalar field, dilaton. We also sketch how this theoretical approach makes it appropriate to revisit non- Newtonian gravity featuring small violation of Weak Equivalence Principle at medium distances.

  12. Varying Fine-Structure Constant and the Cosmological Constant Problem

    Science.gov (United States)

    Fujii, Yasunori

    We start with a brief account of the latest analysis of the Oklo phenomenon providing the still most stringent constraint on time variability of the fine-structure constant α. Comparing this with the recent result from the measurement of distant QSO's appears to indicate a non-uniform time-dependence, which we argue to be related to another recent finding of the accelerating universe. This view is implemented in terms of the scalar-tensor theory, applied specifically to the small but nonzero cosmological constant. Our detailed calculation shows that these two phenomena can be understood in terms of a common origin, a particular behavior of the scalar field, dilaton. We also sketch how this theoretical approach makes it appropriate to revisit non-Newtonian gravity featuring small violation of Weak Equivalence Principle at medium distances.

  13. An Illumination Correction ALgorithm on Landsat-TM Data

    Science.gov (United States)

    Tan, Bin; Wolfe, Robert; Masek, Jeffrey; Gao, Feng; Vermote, Eric F.

    2010-01-01

    In this paper, a new illumination correction model, the rotation model, is introduced. The model is based on the empirical correlation between reflectance and the illumination condition (IL). The model eliminates the dependency of reflectance on IL through rotating the data in IL-reflectance space. This model is compared with widely used cosine model and C model over a sample forest region. We found that the newly developed rotation model consistently performs best on both atmospheric uncorrected and corrected Landsat images. Index Terms Landsat, illumination correction, change detection, LEDAPS

  14. IODC 2014 Illumination design problem: the Cinderella Lamp

    Science.gov (United States)

    Cassarly, William J.

    2014-12-01

    For the 3rd time, the International Optical Design Conference (IODC) included an Illumination Design contest. This year, the contest involved designing the illuminator to project the 1950 Walt Disney "Cinderella" movie using a box of optical knick-knacks. The goal of the problem was to provide the highest screen lumens with greater than 30% uniformity. There were 12 entries from 3 different countries. Three different commercial optical/illumination design packages were used. The winning solution, provided by Alois Herkommer, provided 371 screen lumens.

  15. Effect of ultraviolet illumination on metal oxide resistive memory

    KAUST Repository

    Duran Retamal, Jose Ramon

    2014-12-22

    We investigate the photoelectrical and resistive switching properties of Pt/ZnO/Pt capacitor operated in unipolar mode under ultraviolet (UV) illumination. The oxygen photodesorption under UV illumination explains the photoconduction observed in initial and high resistance states. Meanwhile, oxygen readsorption at surface-related defects justifies the different photoresponses dynamics in both states. Finally, UV illumination significantly reduces the variations of resistance in high resistance state, set voltage and reset voltage by 58%, 33%, and 25%, respectively, stabilizing Pt/ZnO/Pt capacitor. Our findings in improved switching uniformity via UV light give physical insight into designing resistive memory devices.

  16. Design and Analysis of Diffractive Axicons for Gaussian Beam Illumination

    Institute of Scientific and Technical Information of China (English)

    PU Jixiong; Shojiro Nemoto

    2001-01-01

    The diffractive axicon for the illumination with Gaussian beams is designed. The stationary phase method and the numerical calculation are used to analyze the diffraction integral describing the diffraction field. It is shown that with the Gaussian beam illumination of a smaller beam radius, the axicon can produces the uniform-axial-intensity with the lower oscillation frequency and the smaller oscillation amplitude. In addition, with the Gaussian beam illumination of a suitable beam radius, we can achieve the more uniform central-core width.

  17. Spatially incoherent illumination interferometry: a PSF almost insensitive to aberrations

    CERN Document Server

    Xiao, Peng; Boccara, A Claude

    2016-01-01

    We show that with spatially incoherent illumination, the point spread function width of an imaging interferometer like that used in full-field optical coherence tomography (FFOCT) is almost insensitive to aberrations that mostly induce a reduction of the signal level without broadening. This is demonstrated by comparison with traditional scanning OCT and wide-field OCT with spatially coherent illuminations. Theoretical analysis, numerical calculation as well as experimental results are provided to show this specific merit of incoherent illumination in full-field OCT. To the best of our knowledge, this is the first time that such result has been demonstrated.

  18. The legibility of pictograms on colored surfaces under different illuminants

    Directory of Open Access Journals (Sweden)

    Dorotea Kovačević

    2014-07-01

    Full Text Available Ambient lighting conditions, under which the packaging is viewed, in a large extent determine the visual perception of information applied on it. This study investigated how different illuminants affect the legibility of pictograms intended for application on different colored packaging. 87 participants observed the pictograms on blue, red and yellow colored backgrounds in a viewing booth which assured controlled lightning conditions. The results indicated that the legibility of pictograms varied in dependence of the used background color. The best performance was obtained by pictograms designed on a yellow background. Furthermore, it was found that the pictograms were significantly more legible under illuminant A compared to the other tested illuminants.

  19. The effects of different atmospheric conditions on device stability of organic small-molecule solar cells under constant illumination

    Science.gov (United States)

    Karak, S.; Pradhan, S.; Dhar, A.

    2011-09-01

    A systematic study is presented on various effects of different environmental conditions on stability and degradation of small-molecule organic solar cells under continuous simulated solar radiation. Devices were fabricated based on heterojunctions with pentacene and copper phthalocyanine as donor, and [6,6]-phenyl C61 butyric acid methyl ester as acceptor materials. Seven different operating conditions were employed to investigate their degradation stability. Three simultaneous mechanisms were found to be largely responsible for device degradation: (i) photo-oxidation of active materials in the presence of light and oxygen that results in a drop of photocarrier generation and electrical transport properties of the cells, (ii) morphology instability with UV annealing reducing the charge transport within the devices and (iii) bubble formation in the vicinity of the electrodes with moisture absorption, affecting charge collection efficiency of the cells. Significant improvement in device stability was found by careful choice of operating conditions and proper encapsulation. Device lifetime enhanced by almost 100 times under UV filtered vacuum environment or with polydimethylsiloxane encapsulation as compared to a cell operated under ambient conditions without encapsulation.

  20. New Quasar Studies Keep Fundamental Physical Constant Constant

    Science.gov (United States)

    2004-03-01

    Very Large Telescope sets stringent limit on possible variation of the fine-structure constant over cosmological time Summary Detecting or constraining the possible time variations of fundamental physical constants is an important step toward a complete understanding of basic physics and hence the world in which we live. A step in which astrophysics proves most useful. Previous astronomical measurements of the fine structure constant - the dimensionless number that determines the strength of interactions between charged particles and electromagnetic fields - suggested that this particular constant is increasing very slightly with time. If confirmed, this would have very profound implications for our understanding of fundamental physics. New studies, conducted using the UVES spectrograph on Kueyen, one of the 8.2-m telescopes of ESO's Very Large Telescope array at Paranal (Chile), secured new data with unprecedented quality. These data, combined with a very careful analysis, have provided the strongest astronomical constraints to date on the possible variation of the fine structure constant. They show that, contrary to previous claims, no evidence exist for assuming a time variation of this fundamental constant. PR Photo 07/04: Relative Changes with Redshift of the Fine Structure Constant (VLT/UVES) A fine constant To explain the Universe and to represent it mathematically, scientists rely on so-called fundamental constants or fixed numbers. The fundamental laws of physics, as we presently understand them, depend on about 25 such constants. Well-known examples are the gravitational constant, which defines the strength of the force acting between two bodies, such as the Earth and the Moon, and the speed of light. One of these constants is the so-called "fine structure constant", alpha = 1/137.03599958, a combination of electrical charge of the electron, the Planck constant and the speed of light. The fine structure constant describes how electromagnetic forces hold

  1. Constant-bandwidth constant-temperature hot-wire anemometer.

    Science.gov (United States)

    Ligeza, P

    2007-07-01

    A constant-temperature anemometer (CTA) enables the measurement of fast-changing velocity fluctuations. In the classical solution of CTA, the transmission band is a function of flow velocity. This is a minor drawback when the mean flow velocity does not significantly change, though it might lead to dynamic errors when flow velocity varies over a considerable range. A modification is outlined, whereby an adaptive controller is incorporated in the CTA system such that the anemometer's transmission band remains constant in the function of flow velocity. For that purpose, a second feedback loop is provided, and the output signal from the anemometer will regulate the controller's parameters such that the transmission bandwidth remains constant. The mathematical model of a CTA that has been developed and model testing data allow a through evaluation of the proposed solution. A modified anemometer can be used in measurements of high-frequency variable flows in a wide range of velocities. The proposed modification allows the minimization of dynamic measurement errors.

  2. Critical illumination condenser for x-ray lithography

    Science.gov (United States)

    Cohen, S.J.; Seppala, L.G.

    1998-04-07

    A critical illumination condenser system is disclosed, particularly adapted for use in extreme ultraviolet (EUV) projection lithography based on a ring field imaging system and a laser produced plasma source. The system uses three spherical mirrors and is capable of illuminating the extent of the mask plane by scanning either the primary mirror or the laser plasma source. The angles of radiation incident upon each mirror of the critical illumination condenser vary by less than eight (8) degrees. For example, the imaging system in which the critical illumination condenser is utilized has a 200 {micro}m source and requires a magnification of 26. The three spherical mirror system constitutes a two mirror inverse Cassegrain, or Schwarzschild configuration, with a 25% area obstruction (50% linear obstruction). The third mirror provides the final pupil and image relay. The mirrors include a multilayer reflective coating which is reflective over a narrow bandwidth. 6 figs.

  3. Research of global illumination algorithms rendering in glossy scene

    Institute of Scientific and Technical Information of China (English)

    BAI Shuangxue; ZHANG Qiang; ZHOU Dongsheng

    2012-01-01

    In computer graphic (CG), illumination rendering generated realistic effect at virtual scene is amazing. Not only plausible lighting effect is to show the relative position between of the objects, but also to reflect the material of visual appearance of the vir- tual objects. The diffuse-scene rendering reflectance credibility has gradually matured. Global illumination rendering method for the glossy material is still a challenge for the CG research. Because of the shiny materials is highly energy reflection between the com- plex light paths. Whether we trace glossy reflection paths, or use of one-reflection or multi-reflection approximate above complex il- lumination transmission is a difficult working. This paper we gather some commonly used global illumination algorithms recently year and its extension glossy scene improvements. And we introduce the limitation of classical algorithms rendering glossy scene and some extended solution. Finally, we will summarize the illumination rendering for specular scene, there are still some open prob- lems.

  4. PHYTOCHEMICAL CONTENT IN BLUEBERRIES IS INFLUENCED BY UV ILLUMINATION

    Science.gov (United States)

    The levels of phytochemicals in blueberries were found to increase after illumination with UV-C light. Phytochemicals affected included resveratrol, myricetin 3-arabinoside, quercetin 3-galactoside, quercetin 3-arabinoside, quercetin derivative, kaempferol 3-glucoside, delphinidin-3-galactoside, cy...

  5. Illumination and Reflectance Estimation with its Application in Foreground Detection

    Directory of Open Access Journals (Sweden)

    Gang Jun Tu

    2015-08-01

    Full Text Available In this paper, we introduce a novel approach to estimate the illumination and reflectance of an image. The approach is based on illumination-reflectance model and wavelet theory. We use a homomorphic wavelet filter (HWF and define a wavelet quotient image (WQI model based on dyadic wavelet transform. The illumination and reflectance components are estimated by using HWF and WQI, respectively. Based on the illumination and reflectance estimation we develop an algorithm to segment sows in grayscale video recordings which are captured in complex farrowing pens. Experimental results demonstrate that the algorithm can be applied to detect the domestic animals in complex environments such as light changes, motionless foreground objects and dynamic background.

  6. ILLUMINANCE EVALUATION AND ASSESSMENT AT THREE ELEMENTARY SCHOOLS

    Directory of Open Access Journals (Sweden)

    Ahmed Cherif Megri

    2014-01-01

    Full Text Available A simplified model for illuminance prediction has been developed to estimate the indoor level of lighting under artificial lighting. As well, illuminance in several locations of three schools has been measured under several conditions: Blinds up/lights on, blinds up/lights off, blinds down/lights on, blinds down/lights off. The experimental data of the case “blinds down/lights on” has been compared to the model developed and the results are very encouraging. The purpose of this study is to identify the level of illuminance in elementary schools classroom, to compare it to the IES requirements and the values predicted by the program developed. A parametric study has been performed to study the effect of the Light Loss Factor (LLF and the luminous power on the lighting and energy performance of the illumination system.

  7. Local Relation Map: A Novel Illumination Invariant Face Recognition Approach

    Directory of Open Access Journals (Sweden)

    Lian Zhichao

    2012-10-01

    Full Text Available In this paper, a novel illumination invariant face recognition approach is proposed. Different from most existing methods, an additive term as noise is considered in the face model under varying illuminations in addition to a multiplicative illumination term. High frequency coefficients of Discrete Cosine Transform (DCT are discarded to eliminate the effect caused by noise. Based on the local characteristics of the human face, a simple but effective illumination invariant feature local relation map is proposed. Experimental results on the Yale B, Extended Yale B and CMU PIE demonstrate the outperformance and lower computational burden of the proposed method compared to other existing methods. The results also demonstrate the validity of the proposed face model and the assumption on noise.

  8. An inexpensive programmable illumination microscope with active feedback

    Science.gov (United States)

    Tompkins, Nathan; Fraden, Seth

    2016-02-01

    We have developed a programmable illumination system capable of tracking and illuminating numerous objects simultaneously using only low-cost and reused optical components. The active feedback control software allows for a closed-loop system that tracks and perturbs objects of interest automatically. Our system uses a static stage where the objects of interest are tracked computationally as they move across the field of view allowing for a large number of simultaneous experiments. An algorithmically determined illumination pattern can be applied anywhere in the field of view with simultaneous imaging and perturbation using different colors of light to enable spatially and temporally structured illumination. Our system consists of a consumer projector, camera, 35-mm camera lens, and a small number of other optical and scaffolding components. The entire apparatus can be assembled for under 4,000. Supplemental matlab code is available to assist in the setup of the active feedback software.

  9. Advanced split-illumination electron holography without Fresnel fringes

    Energy Technology Data Exchange (ETDEWEB)

    Tanigaki, Toshiaki, E-mail: tanigaki-toshiaki@riken.jp [Center for Emergent Matter Science (CEMS), RIKEN, Hirosawa 2-1, Wako, Saitama 351-0198 (Japan); Aizawa, Shinji; Park, Hyun Soon [Center for Emergent Matter Science (CEMS), RIKEN, Hirosawa 2-1, Wako, Saitama 351-0198 (Japan); Matsuda, Tsuyoshi [Japan Science and Technology Agency, Kawaguchi, Saitama 332-0012 (Japan); Harada, Ken [Central Research Laboratory, Hitachi, Ltd., Hatoyama, Saitama 350-0395 (Japan); Shindo, Daisuke [Center for Emergent Matter Science (CEMS), RIKEN, Hirosawa 2-1, Wako, Saitama 351-0198 (Japan); Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Katahira 2-1-1, Sendai 980-8577 (Japan)

    2014-02-01

    Advanced split-illumination electron holography was developed by employing two biprisms in the illuminating system to split an electron wave into two coherent waves and two biprisms in the imaging system to overlap them. A focused image of an upper condenser-biprism filament was formed on the sample plane, and all other filaments were placed in its shadow. This developed system makes it possible to obtain precise reconstructed object waves without modulations due to Fresnel fringes, in addition to holograms of distant objects from reference waves. - Highlights: • Advanced split-illumination electron holography without Fresnel fringes is developed. • Two biprisms are installed in illuminating system of microscope. • High-precision holographic observations of an area locating far from the sample edge become possible.

  10. Two bumblebee genomes illuminate the route to advanced social living

    Science.gov (United States)

    Social living represents a major evolutionary transition. Primitively eusocial bumblebees are uniquely placed to illuminate the evolutionary route from solitary to highly eusocial insect societies, for which molecular level information is largely lacking. Additionally, bumblebees are invaluable natu...

  11. An inexpensive programmable illumination microscope with active feedback

    Science.gov (United States)

    Tompkins, Nathan; Fraden, Seth

    2016-01-01

    We have developed a programmable illumination system capable of tracking and illuminating numerous objects simultaneously using only low-cost and reused optical components. The active feedback control software allows for a closed-loop system that tracks and perturbs objects of interest automatically. Our system uses a static stage where the objects of interest are tracked computationally as they move across the field of view allowing for a large number of simultaneous experiments. An algorithmically determined illumination pattern can be applied anywhere in the field of view with simultaneous imaging and perturbation using different colors of light to enable spatially and temporally structured illumination. Our system consists of a consumer projector, camera, 35-mm camera lens, and a small number of other optical and scaffolding components. The entire apparatus can be assembled for under $4,000. PMID:27642182

  12. On the spectral quality of scanner illumination with LEDs

    Science.gov (United States)

    Cui, Chengwu

    2013-01-01

    Document scanner illumination has evolved along with general illumination technologies. LEDs have become more and more popular as the illumination sources for document scanning. LED technologies provide a wide range of choices both in terms of structural design and spectral compositions. In this report, we examine some popular LED technologies used for document scanner. We evaluate the color rendering performance of scanner models with different illumination technologies by examining their rendering of the Macbeth ColorChecker™ in sRGB. We found that more phosphors in phosphor conversion types of white LEDs may not be necessarily advantageous in terms of scanner color rendering performance. Also CIS type of scanner may be sensitive to the peak wavelength shift and can be particularly problematic when the peaks are out of certain range.

  13. Three pion nucleon coupling constants

    CERN Document Server

    Arriola, E Ruiz; Perez, R Navarro

    2016-01-01

    There exist four pion nucleon coupling constants, $f_{\\pi^0, pp}$, $-f_{\\pi^0, nn}$, $f_{\\pi^+, pn} /\\sqrt{2}$ and $ f_{\\pi^-, np} /\\sqrt{2}$ which coincide when up and down quark masses are identical and the electron charge is zero. While there is no reason why the pion-nucleon-nucleon coupling constants should be identical in the real world, one expects that the small differences might be pinned down from a sufficiently large number of independent and mutually consistent data. Our discussion provides a rationale for our recent determination $$f_p^2 = 0.0759(4) \\, , \\quad f_{0}^2 = 0.079(1) \\,, \\quad f_{c}^2 = 0.0763(6) \\, , $$ based on a partial wave analysis of the $3\\sigma$ self-consistent nucleon-nucleon Granada-2013 database comprising 6713 published data in the period 1950-2013.

  14. Time-Varying Fundamental Constants

    Science.gov (United States)

    Olive, Keith

    2003-04-01

    Recent data from quasar absorption systems can be interpreted as arising from a time variation in the fine-structure constant. However, there are numerous cosmological, astro-physical, and terrestrial bounds on any such variation. These includes bounds from Big Bang Nucleosynthesis (from the ^4He abundance), the Oklo reactor (from the resonant neutron capture cross-section of Sm), and from meteoretic lifetimes of heavy radioactive isotopes. The bounds on the variation of the fine-structure constant are significantly strengthened in models where all gauge and Yukawa couplings vary in a dependent manner, as would be expected in unified theories. Models which are consistent with all data are severly challenged when Equivalence Principle constraints are imposed.

  15. Illumination normalization based on simplified local binary patterns for a face verification system

    NARCIS (Netherlands)

    Tao, Q.; Veldhuis, Raymond N.J.

    2007-01-01

    Illumination normalization is a very important step in face recognition. In this paper we propose a simple implementation of Local Binary Patterns, which effectively reduces the variability caused by illumination changes. In combination with a likelihood ratio classifier, this illumination

  16. Stability for Quantitative Photoacoustic Tomography with well chosen illuminations

    OpenAIRE

    Alessandrini, Giovanni; Di Cristo, Michele; Francini, Elisa; Vessella, Sergio

    2015-01-01

    We treat the stability issue for the three dimensional inverse imaging modality called Quantitative Photoacoustic Tomography. We provide universal choices of the illuminations which enable to recover, in a H\\"older stable fashion, the diffusion and absorption coefficients from the interior pressure data. With such choices of illuminations we do not need the nondegeneracy conditions commonly used in previous studies, which are difficult to be verified a-priori.

  17. Face colour under varying illumination - analysis and applications

    OpenAIRE

    Martinkauppi, B. (Birgitta)

    2002-01-01

    Abstract The colours of objects perceived by a colour camera are dependent on the illumination conditions. For example, when the prevailing illumination condition does not correspond to the one used in the white balancing of the camera, the object colours can change their appearance due to the lack of colour constancy capabilities. Many methods for colour constancy have been suggested but so far their performance has been inadequate. Faces are common and important objects encountered in ma...

  18. Fiber Coupled Laser Diodes with Even Illumination Pattern

    Science.gov (United States)

    Howard, Richard T. (Inventor)

    2007-01-01

    An optical fiber for evenly illuminating a target. The optical fiber is coupled to a laser emitting diode and receives laser light. The la ser light travels through the fiber optic and exits at an exit end. T he exit end has a diffractive optical pattern formed thereon via etch ing, molding or cutting, to reduce the Gaussian profile present in co nventional fiber optic cables The reduction of the Gaussian provides an even illumination from the fiber optic cable.

  19. Advanced illumination control algorithm for medical endoscopy applications

    Science.gov (United States)

    Sousa, Ricardo M.; Wäny, Martin; Santos, Pedro; Morgado-Dias, F.

    2015-05-01

    CMOS image sensor manufacturer, AWAIBA, is providing the world's smallest digital camera modules to the world market for minimally invasive surgery and one time use endoscopic equipment. Based on the world's smallest digital camera head and the evaluation board provided to it, the aim of this paper is to demonstrate an advanced fast response dynamic control algorithm of the illumination LED source coupled to the camera head, over the LED drivers embedded on the evaluation board. Cost efficient and small size endoscopic camera modules nowadays embed minimal size image sensors capable of not only adjusting gain and exposure time but also LED illumination with adjustable illumination power. The LED illumination power has to be dynamically adjusted while navigating the endoscope over changing illumination conditions of several orders of magnitude within fractions of the second to guarantee a smooth viewing experience. The algorithm is centered on the pixel analysis of selected ROIs enabling it to dynamically adjust the illumination intensity based on the measured pixel saturation level. The control core was developed in VHDL and tested in a laboratory environment over changing light conditions. The obtained results show that it is capable of achieving correction speeds under 1 s while maintaining a static error below 3% relative to the total number of pixels on the image. The result of this work will allow the integration of millimeter sized high brightness LED sources on minimal form factor cameras enabling its use in endoscopic surgical robotic or micro invasive surgery.

  20. Shading-based Surface Detail Recovery under General Unknown Illumination.

    Science.gov (United States)

    Xu, Di; Duan, Qi; Zheng, Jianmin; Zhang, Juyong; Cai, Jianfei; Cham, Tat-Jen

    2017-02-17

    Reconstructing the shape of a 3D object from multi-view images under unknown, general illumination is a fundamental problem in computer vision and high quality reconstruction is usually challenging especially when fine detail is needed and the albedo of the object is non-uniform. This paper introduces vertex overall illumination vectors to model the illumination effect and presents a total variation (TV) based approach for recovering surface details using shading and multi-view stereo (MVS). Behind the approach are the two important observations: (1) the illumination over the surface of an object often appears to be piece wise smooth and (2) the recovery of surface orientation is not sufficient for reconstructing the surface, which was often overlooked previously. Thus we propose to use TV to regularize the overall illumination vectors and use visual hull to constrain partial vertices. The reconstruction is formulated as a constrained TV-minimization problem that simultaneously treats the shape and illumination vectors as unknowns. An augmented Lagrangian method is proposed to quickly solve the TV-minimization problem. As a result, our approach is robust, stable and is able to efficiently recover high quality of surface details even when starting with a coarse model obtained using MVS. These advantages are demonstrated by extensive experiments on the state-of-the-art MVS database, which includes challenging objects with varying albedo.

  1. Spiral wobbling beam illumination uniformity in HIF fuel target implosion

    Directory of Open Access Journals (Sweden)

    Kawata S.

    2013-11-01

    Full Text Available A few % wobbling-beam illumination nonuniformity is realized in heavy ion inertial confinement fusion (HIF throughout the heavy ion beam (HIB driver pulse by a newly introduced spiraling beam axis motion in the first two rotations. The wobbling HIB illumination was proposed to realize a uniform implosion in HIF. However, the initial imprint of the wobbling HIBs was a serious problem and introduces a large unacceptable energy deposition nonuniformity. In the wobbling HIBs illumination, the illumination nonuniformity oscillates in time and space. The oscillating-HIB energy deposition may produce a time-dependent implosion acceleration, which reduces the Rayleigh-Taylor (R-T growth [Laser Part. Beams 11, 757 (1993, Nuclear Inst. Methods in Phys. Res. A 606, 152 (2009, Phys. Plasmas 19, 024503 (2012] and the implosion nonuniformity. The wobbling HIBs can be generated in HIB accelerators and the oscillating frequency may be several 100 MHz ∼ 1 GHz [Phys. Rev. Lett. 104, 254801 (2010]. Three-dimensional HIBs illumination computations present that the few % wobbling HIBs illumination nonuniformity oscillates with the same wobbling HIBs frequency.

  2. Real-time Global Illumination by Simulating Photon Mapping

    DEFF Research Database (Denmark)

    Larsen, Bent Dalgaard

    2004-01-01

    This thesis introduces a new method for simulating photon mapping in realtime. The method uses a variety of both CPU and GPU based algorithms for speeding up the different elements in global illumination. The idea behind the method is to calculate each illumination element individually in a progr......This thesis introduces a new method for simulating photon mapping in realtime. The method uses a variety of both CPU and GPU based algorithms for speeding up the different elements in global illumination. The idea behind the method is to calculate each illumination element individually...... in a progressive and efficient manner. This has been done by analyzing the photon mapping method and by selecting efficient methods, either CPU based or GPU based, which replaces the original photon mapping algorithms. We have chosen to focus on the indirect illumination and the caustics. In our method we first...... divide the photon map into several photon maps in order to make local updates possible. Then indirect illumination is added using light maps that are selectively updated by using selective photon tracing on the CPU. The final gathering step is calculated by using fragment programs and GPU based...

  3. Naturalness preserved enhancement algorithm for non-uniform illumination images.

    Science.gov (United States)

    Wang, Shuhang; Zheng, Jin; Hu, Hai-Miao; Li, Bo

    2013-09-01

    Image enhancement plays an important role in image processing and analysis. Among various enhancement algorithms, Retinex-based algorithms can efficiently enhance details and have been widely adopted. Since Retinex-based algorithms regard illumination removal as a default preference and fail to limit the range of reflectance, the naturalness of non-uniform illumination images cannot be effectively preserved. However, naturalness is essential for image enhancement to achieve pleasing perceptual quality. In order to preserve naturalness while enhancing details, we propose an enhancement algorithm for non-uniform illumination images. In general, this paper makes the following three major contributions. First, a lightness-order-error measure is proposed to access naturalness preservation objectively. Second, a bright-pass filter is proposed to decompose an image into reflectance and illumination, which, respectively, determine the details and the naturalness of the image. Third, we propose a bi-log transformation, which is utilized to map the illumination to make a balance between details and naturalness. Experimental results demonstrate that the proposed algorithm can not only enhance the details but also preserve the naturalness for non-uniform illumination images.

  4. Off-axis illumination direct-to-digital holography

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Clarence E.; Price, Jeffery R.; Voelkl, Edgar; Hanson, Gregory R.

    2004-06-08

    Systems and methods are described for off-axis illumination direct-to-digital holography. A method of recording an off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis, includes: reflecting a reference beam from a reference mirror at a non-normal angle; reflecting an object beam from an object at an angle with respect to an optical axis defined by a focusing lens; focusing the reference beam and the object beam at a focal plane of a digital recorder to form the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; digitally recording the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; Fourier analyzing the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes by transforming axes of the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes in Fourier space to sit on top of a heterodyne carrier frequency defined as an angle between the reference beam and the object beam; applying a digital filter to cut off signals around an original origin; and then performing an inverse Fourier transform.

  5. Why isn't the solar constant a constant?

    CERN Document Server

    Li, K J; Xu, J C; Gao, P X; Yang, L H; Liang, H F; Zhan, L S

    2012-01-01

    In order to probe the mechanism of variations of the Solar Constant on the inter-solar-cycle scale, total solar irradiance (TSI, the so-called Solar Constant) in the time interval of 7 November 1978 to 20 September 2010 is decomposed into three components through the empirical mode decomposition and time-frequency analyses. The first component is the rotation signal, counting up to 42.31% of the total variation of TSI, which is understood to be mainly caused by large magnetic structures, including sunspot groups. The second is an annual-variation signal, counting up to 15.17% of the total variation, the origin of which is not known at this point in time. Finally, the third is the inter-solar-cycle signal, counting up to 42.52%, which are inferred to be caused by the network magnetic elements in quiet regions, whose magnetic flux ranges from $(4.27-38.01)\\times10^{19}$ Mx.

  6. Fine-structure constant: Is it really a constant?

    Science.gov (United States)

    Bekenstein, Jacob D.

    1982-03-01

    It is often claimed that the fine-structure "constant" α is shown to be strictly constant in time by a variety of astronomical and geophysical results. These constrain its fractional rate of change α˙α to at least some orders of magnitude below the Hubble rate H0. We argue that the conclusion is not as straightforward as claimed since there are good physical reasons to expect α˙α<

  7. Cryptography in constant parallel time

    CERN Document Server

    Applebaum, Benny

    2013-01-01

    Locally computable (NC0) functions are 'simple' functions for which every bit of the output can be computed by reading a small number of bits of their input. The study of locally computable cryptography attempts to construct cryptographic functions that achieve this strong notion of simplicity and simultaneously provide a high level of security. Such constructions are highly parallelizable and they can be realized by Boolean circuits of constant depth.This book establishes, for the first time, the possibility of local implementations for many basic cryptographic primitives such as one-way func

  8. Henry's law constants of polyols

    Directory of Open Access Journals (Sweden)

    S. Compernolle

    2014-05-01

    Full Text Available Henry's law constants (HLC are derived for several polyols bearing between 2 and 6 hydroxyl groups, based on literature data for water activity, vapour pressure and/or solubility. Depending on the case, infinite dilution activity coefficients (IDACs, solid state pressures or activity coefficient ratios are obtained as intermediary results. For most compounds, these are the first values reported, while others compare favourably with literature data in most cases. Using these values and those from a previous work (Compernolle and Müller, 2014, an assessment is made on the partitioning of polyols, diacids and hydroxy acids to droplet and aqueous aerosol.

  9. Exact constants in approximation theory

    CERN Document Server

    Korneichuk, N

    1991-01-01

    This book is intended as a self-contained introduction for non-specialists, or as a reference work for experts, to the particular area of approximation theory that is concerned with exact constants. The results apply mainly to extremal problems in approximation theory, which in turn are closely related to numerical analysis and optimization. The book encompasses a wide range of questions and problems: best approximation by polynomials and splines; linear approximation methods, such as spline-approximation; optimal reconstruction of functions and linear functionals. Many of the results are base

  10. Illumination Conditions of the Lunar Polar Regions Using LOLA Topography

    Science.gov (United States)

    Mazarico, E.; Neumann, G. A.; Smith, D. E.; Zuber, M. T.; Torrence, M. H.

    2011-01-01

    We use high-resolution altimetry data obtained by the Lunar Orbiter Laser Altimeter instrument onboard the Lunar Reconnaissance Orbiter to characterize present illumination conditions in the polar regions of the Moon. Compared to previous studies, both the spatial and temporal extent of the simulations are increased significantly, as well as the coverage (fill ratio) of the topographic maps used, thanks to the 28 Hz firing rate of the five-beam instrument. We determine the horizon elevation in a number of directions based on 240 m-resolution polar digital elevation models reaching down to 75 latitude. The illumination of both polar regions extending to 80 can be calculated for any geometry from those horizon longitudinal profiles. We validated our modeling with recent Lunar Reconnaissance Orbiter Wide-Angle Camera images. We assessed the extent of permanently shadowed regions (PSRs, defined as areas that never receive direct solar illumination), and obtained total areas generally larger than previous studies (12,866 and 16,055 km2, in the north and south respectively). We extended our direct illumination model to account for singly-scattered light, and found that every PSR does receive some amount of scattered light during the year. We conducted simulations over long periods (several 18.6-years lunar precession cycles) with a high temporal resolution (6 h), and identified the most illuminated locations in the vicinity of both poles. Because of the importance of those sites for exploration and engineering considerations, we characterized their illumination more precisely over the near future. Every year, a location near the Shackleton crater rim in the south polar region is sunlit continuously for 240 days, and its longest continuous period in total darkness is about 1.5 days. For some locations small height gains ( 10 m) can dramatically improve their average illumination and reduce the night duration, rendering some of those particularly attractive energy-wise as

  11. Illumination pattern optimization for fluorescence tomography: theory and simulation studies.

    Science.gov (United States)

    Dutta, Joyita; Ahn, Sangtae; Joshi, Anand A; Leahy, Richard M

    2010-05-21

    Fluorescence molecular tomography is a powerful tool for 3D visualization of molecular targets and pathways in vivo in small animals. Owing to the high degrees of absorption and scattering of light through tissue, the fluorescence tomographic inverse problem is inherently ill-posed. In order to improve source localization and the conditioning of the light propagation model, multiple sets of data are acquired by illuminating the animal surface with different spatial patterns of near-infrared light. However, the choice of these patterns in most experimental setups is ad hoc and suboptimal. This paper presents a systematic approach for designing efficient illumination patterns for fluorescence tomography. Our objective here is to determine how to optimally illuminate the animal surface so as to maximize the information content in the acquired data. We achieve this by improving the conditioning of the Fisher information matrix. We parameterize the spatial illumination patterns and formulate our problem as a constrained optimization problem that, for a fixed number of illumination patterns, yields the optimal set of patterns. For geometric insight, we used our method to generate a set of three optimal patterns for an optically homogeneous, regular geometrical shape and observed expected symmetries in the result. We also generated a set of six optimal patterns for an optically homogeneous cuboidal phantom set up in the transillumination mode. Finally, we computed optimal illumination patterns for an optically inhomogeneous realistically shaped mouse atlas for different given numbers of patterns. The regularized pseudoinverse matrix, generated using the singular value decomposition, was employed to reconstruct the point spread function for each set of patterns in the presence of a sample fluorescent point source deep inside the mouse atlas. We have evaluated the performance of our method by examining the singular value spectra as well as plots of average spatial

  12. Kepler's Constant and WDS Orbit

    CERN Document Server

    Siregar, S

    2012-01-01

    The aim of this work are to find a Kepler's constant by using polynomial regression of the angular separation \\rho = \\rho(t) and the position angle \\theta = \\theta(t). The Kepler's constant obtained is used to derive the element of orbit. As a case study the angular separation and the position angle of the WDS 00063 +5826 and the WDS 04403-5857 were investigated. For calculating the element of orbit the Thiele-Innes van den Bos method is used. The rough data of the angular separation \\rho(t) and the position angle \\theta(t) are taken from the US Naval Observatory, Washington. This work also presents the masses and absolute bolometric magnitudes of each star.These stars include into the main-sequence stars with the spectral class G5V for WDS04403-5857and the type of spectrum G3V for WDS 00063+5826. The life time of the primary star and the secondary star of WDS 04403-5857 nearly equal to 20 Gyr. The life time of the primary star and the secondary star of WDS 00063+5826 are 20 Gyr and 19 Gyr, respectively.

  13. Graphs with constant μ and μ

    NARCIS (Netherlands)

    van Dam, E.R.; Haemers, W.H.

    1995-01-01

    A graph G has constant u = u(G) if any two vertices that are not adjacent have u common neighbours. G has constant u and u if G has constant u = u(G), and its complement G has constant u = u(G). If such a graph is regular, then it is strongly regular, otherwise precisely two vertex degrees occur. We

  14. Cosmological constant and curved 5D geometry

    CERN Document Server

    Ito, M

    2002-01-01

    We study the value of cosmological constant in de Sitter brane embedded in five dimensions with positive, vanishing and negative bulk cosmological constant. In the case of negative bulk cosmological constant, we show that not zero but tiny four-dimensional cosmological constant can be realized by tiny deviation from bulk curvature of the Randall-Sundrum model.

  15. Stability constant estimator user`s guide

    Energy Technology Data Exchange (ETDEWEB)

    Hay, B.P.; Castleton, K.J.; Rustad, J.R.

    1996-12-01

    The purpose of the Stability Constant Estimator (SCE) program is to estimate aqueous stability constants for 1:1 complexes of metal ions with ligands by using trends in existing stability constant data. Such estimates are useful to fill gaps in existing thermodynamic databases and to corroborate the accuracy of reported stability constant values.

  16. Low-resolution face tracker robust to illumination variations.

    Science.gov (United States)

    Zou, Wilman W; Yuen, Pong C; Chellappa, Rama

    2013-05-01

    In many practical video surveillance applications, the faces acquired by outdoor cameras are of low resolution and are affected by uncontrolled illumination. Although significant efforts have been made to facilitate face tracking or illumination normalization in unconstrained videos, the approaches developed may not be effective in video surveillance applications. This is because: 1) a low-resolution face contains limited information, and 2) major changes in illumination on a small region of the face make the tracking ineffective. To overcome this problem, this paper proposes to perform tracking in an illumination-insensitive feature space, called the gradient logarithm field (GLF) feature space. The GLF feature mainly depends on the intrinsic characteristics of a face and is only marginally affected by the lighting source. In addition, the GLF feature is a global feature and does not depend on a specific face model, and thus is effective in tracking low-resolution faces. Experimental results show that the proposed GLF-based tracker works well under significant illumination changes and outperforms many state-of-the-art tracking algorithms.

  17. Spectrally optimal illuminations for diabetic retinopathy detection in retinal imaging

    Science.gov (United States)

    Bartczak, Piotr; Fält, Pauli; Penttinen, Niko; Ylitepsa, Pasi; Laaksonen, Lauri; Lensu, Lasse; Hauta-Kasari, Markku; Uusitalo, Hannu

    2017-01-01

    Retinal photography is a standard method for recording retinal diseases for subsequent analysis and diagnosis. However, the currently used white light or red-free retinal imaging does not necessarily provide the best possible visibility of different types of retinal lesions, important when developing diagnostic tools for handheld devices, such as smartphones. Using specifically designed illumination, the visibility and contrast of retinal lesions could be improved. In this study, spectrally optimal illuminations for diabetic retinopathy lesion visualization are implemented using a spectrally tunable light source based on digital micromirror device. The applicability of this method was tested in vivo by taking retinal monochrome images from the eyes of five diabetic volunteers and two non-diabetic control subjects. For comparison to existing methods, we evaluated the contrast of retinal images taken with our method and red-free illumination. The preliminary results show that the use of optimal illuminations improved the contrast of diabetic lesions in retinal images by 30-70%, compared to the traditional red-free illumination imaging.

  18. Photobioreactors with internal illumination - A survey and comparison.

    Science.gov (United States)

    Heining, Martin; Buchholz, Rainer

    2015-08-01

    The idea of internally illuminated photobioreactors has existed since the 1990s and various systems were developed since. Recently, the interest in these systems has been on the rise again, due to the increased production of and research on high-value products and recombinant proteins from microalgae and plant cell cultures. While promising results in lab-scale have been achieved, the potential of photoautotrophic or mixotrophic production of these compounds is limited due to the lack of scalable photobioreactors, which could be overcome by internally illuminated systems. In this article, we review different internally illuminated photobioreactors from the last two decades and classify them into two major groups. The photobioreactors are compared based on the ratio of illuminated surface-to-culture volume and the occupied volume by internal light-emitting elements, and possible obstacles, challenges and future trends are discussed. Looking forward, new technologies and smaller light sources have improved the potential of internally illuminated photobioreactors with internal light sources and will enable these technologies to compete with systems with internal light guides, but only a few of these systems have currently achieved a relevant scale.

  19. Characterization of Lunar Polar Illumination from a Power System Perspective

    Science.gov (United States)

    Fincannon, James

    2008-01-01

    This paper presents the results of illumination analyses for the lunar south and north pole regions obtained using an independently developed analytical tool and two types of digital elevation models (DEM). One DEM was based on radar height data from Earth observations of the lunar surface and the other was a combination of the radar data with a separate dataset generated using Clementine spacecraft stereo imagery. The analysis tool enables the assessment of illumination at most locations in the lunar polar regions for any time and any year. Maps are presented for both lunar poles for the worst case winter period (the critical power system design and planning bottleneck) and for the more favorable best case summer period. Average illumination maps are presented to help understand general topographic trends over the regions. Energy storage duration maps are presented to assist in power system design. Average illumination fraction, energy storage duration, solar/horizon terrain elevation profiles and illumination fraction profiles are presented for favorable lunar north and south pole sites which have the potential for manned or unmanned spacecraft operations. The format of the data is oriented for use by power system designers to develop mass optimized solar and energy storage systems.

  20. Polydopamine Generates Hydroxyl Free Radicals under Ultraviolet-Light Illumination.

    Science.gov (United States)

    Wang, Zehuan; Tang, Feng; Fan, Hailong; Wang, Le; Jin, Zhaoxia

    2017-06-13

    Polydopamine (PDA) generally demonstrates as an efficient free-radical scavenger. However, its free-radical chemistry under illumination is unclear, which becomes important in view of growing studies of polydopamine applications in photoprotector and photothermal therapy. In this study, for the first time, we reported an experimental investigation of the generation of hydroxyl free radicals from ultraviolet (UV)-illuminated polydopamine in an aqueous environment. By using terephthalic acid as fluorescent probe, we measured hydroxyl radicals generated from UV-illuminated polydopamine with different shapes and sizes. The morphology of PDA shows significant influence on its productions of hydroxyl free radicals. Through characterizations of UV-vis absorption spectroscopy, fluorescence spectroscopy, X-ray photoelectron spectrometry, mass spectrometry, and thermogravimetric analysis, we demonstrated the change of PDA nanomaterials brought by UV-light illumination in composition and thermal stability. We proposed a tentative mechanism for interpreting the relationship between morphology and photostability of PDA nanomaterials. These results reveal underlying complexity of polydopamine chemistry under light illumination that will deepen our understanding and benefit its further application.

  1. Constant training in direct ophthalmoscopy

    Directory of Open Access Journals (Sweden)

    Younan HC

    2017-08-01

    Full Text Available Helen-Cara Younan, Rishi Iyer, Janaki Natasha DesaiFaculty of Medicine, Imperial College London, London, UKWe read with great interest the review by Ricci and Ferraz on the advances in training and practice in ophthalmoscopy simulation.1As final year medical students, we have recently experienced direct ophthalmoscopy teaching and agree with the authors that “simulation is a helpful tool in ophthalmoscopy training”.1 Indeed, in our experience, simulation is useful in teaching a wide variety of clinical skills including venepuncture, intravenous cannulation, and catheterization. We were taught all of these clinical skills in our first clinical year of study through use of simulation models. With regards to our direct ophthalmoscopy teaching, we were first taught to recognize the normal retina and different retinal pathologies using images, before practicing our technique and recognition of those images in a model similar to the THELMA (The Human Eye Learning Model Assistant described by the authors.1However, we feel that the use of simulation models alone is not enough to provide confidence and competency in direct ophthalmoscopy among medical students. The authors conclude that “constant training is a well-known strategy for skill enhancement”,1 and we have found that a lack of constant training in direct ophthalmoscopy is evident. After learning venepuncture, cannulation, and catheterization on the simulation models, we were able to observe doctors performing these skills before performing them on patients either in the wards or in theatre. These are skills that we are constantly trained in across a wide variety of medical and surgical attachments. However, opportunities to observe and practice ophthalmoscopy during our attachments are more limited, and thus we are not continuing to use the skills we learn.Authors' replyLucas Holderegger Ricci,1 Caroline Amaral Ferraz21Department of Ophthalmology, School of Medicine, Laureate

  2. The fundamental constants a mystery of physics

    CERN Document Server

    Fritzsch, Harald

    2009-01-01

    The speed of light, the fine structure constant, and Newton's constant of gravity — these are just three among the many physical constants that define our picture of the world. Where do they come from? Are they constant in time and across space? In this book, physicist and author Harald Fritzsch invites the reader to explore the mystery of the fundamental constants of physics in the company of Isaac Newton, Albert Einstein, and a modern-day physicist

  3. Coupling constant in dispersive model

    Indian Academy of Sciences (India)

    R Saleh-Moghaddam; M E Zomorrodian

    2013-11-01

    The average of the moments for event shapes in + - → hadrons within the context of next-to-leading order (NLO) perturbative QCD prediction in dispersive model is studied. Moments used in this article are $\\langle 1 - T \\rangle, \\langle ρ \\rangle, \\langle B_{T} \\rangle$ and $\\langle B_{W} \\rangle$. We extract , the coupling constant in perturbative theory and α0 in the non-perturbative theory using the dispersive model. By fitting the experimental data, the values of $(M_{Z^{°}})$ = 0.1171 ± 0.00229 and 0 ($_{I} = 2{\\text{GeV}}$) = 0.5068 ± 0.0440 are found. Our results are consistent with the above model. Our results are also consistent with those obtained from other experiments at different energies. All these features are explained in this paper.

  4. Constant Proportion Debt Obligations (CPDOs)

    DEFF Research Database (Denmark)

    Cont, Rama; Jessen, Cathrine

    2012-01-01

    be made arbitrarily small—and thus the credit rating arbitrarily high—by increasing leverage, but the ratings obtained strongly depend on assumptions on the credit environment (high spread or low spread). More importantly, CPDO loss distributions are found to exhibit a wide range of tail risk measures......Constant Proportion Debt Obligations (CPDOs) are structured credit derivatives that generate high coupon payments by dynamically leveraging a position in an underlying portfolio of investment-grade index default swaps. CPDO coupons and principal notes received high initial credit ratings from...... the major rating agencies, based on complex models for the joint transition of ratings and spreads for all names in the underlying portfolio. We propose a parsimonious model for analysing the performance of CPDO strategies using a top-down approach that captures the essential risk factors of the CPDO. Our...

  5. Henry's law constants of polyols

    Directory of Open Access Journals (Sweden)

    S. Compernolle

    2014-12-01

    Full Text Available Henry's law constants (HLC are derived for several polyols bearing between 2 and 6 hydroxyl groups, based on literature data for water activity, vapour pressure and/or solubility. While deriving HLC and depending on the case, also infinite dilution activity coefficients (IDACs, solid state vapour pressures or activity coefficient ratios are obtained as intermediate results. An error analysis on the intermediate quantities and the obtained HLC is included. For most compounds, these are the first values reported, while others compare favourably with literature data in most cases. Using these values and those from a previous work (Compernolle and Müller, 2014, an assessment is made on the partitioning of polyols, diacids and hydroxy acids to droplet and aqueous aerosol.

  6. Omnidirectional antenna having constant phase

    Energy Technology Data Exchange (ETDEWEB)

    Sena, Matthew

    2017-04-04

    Various technologies presented herein relate to constructing and/or operating an antenna having an omnidirectional electrical field of constant phase. The antenna comprises an upper plate made up of multiple conductive rings, a lower ground-plane plate, a plurality of grounding posts, a conical feed, and a radio frequency (RF) feed connector. The upper plate has a multi-ring configuration comprising a large outer ring and several smaller rings of equal size located within the outer ring. The large outer ring and the four smaller rings have the same cross-section. The grounding posts ground the upper plate to the lower plate while maintaining a required spacing/parallelism therebetween.

  7. Local and Global Illumination in the Volume Rendering Integral

    Energy Technology Data Exchange (ETDEWEB)

    Max, N; Chen, M

    2005-10-21

    This article is intended as an update of the major survey by Max [1] on optical models for direct volume rendering. It provides a brief overview of the subject scope covered by [1], and brings recent developments, such as new shadow algorithms and refraction rendering, into the perspective. In particular, we examine three fundamentals aspects of direct volume rendering, namely the volume rendering integral, local illumination models and global illumination models, in a wavelength-independent manner. We review the developments on spectral volume rendering, in which visible light are considered as a form of electromagnetic radiation, optical models are implemented in conjunction with representations of spectral power distribution. This survey can provide a basis for, and encourage, new efforts for developing and using complex illumination models to achieve better realism and perception through optical correctness.

  8. Daylighting provided by horizontal openings using the illumination vector

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, J.; Sendra, J.J. [Instituto Universitario de Ciencias de la Construccion, Universidad de Sevilla (Spain)

    2006-12-15

    Stemming from the expressions of the illumination vector provided by vertical openings at any point of the interior space, this article proposes and solves the equivalent expressions for openings in horizontal planes, thus completing the expressions of Navarro [Sobre iluminacion natural en arquitectura. Ed. Secretariado de Publicaciones de la Universidad de Sevilla; 1983] and offering algorithms which give the value of the illumination vector for CIE skies [Natural daylight official recommendations. Paris: CIE COMMITE 3.2.; 1955] at any point of the interior space and for any size of window whether vertical or horizontal. This constitutes a highly potential tool of computerized calculation of the direct component of natural illumination which is eminently more flexible and precise than those systems which are based on finite elements. (author)

  9. Image Segmentation using Multi-Coloured Active Illumination

    Directory of Open Access Journals (Sweden)

    Tze Ki Koh

    2007-11-01

    Full Text Available In this paper, the use of active illumination is extended to image segmentation, specifically in the case of overlapping particles. This work is based on Multi-Flash Imaging (MFI, originally developed by Mitsubishi Electric Labs, to detect depth discontinuities. Illuminations of different wavelengths are projected from multiple positions, providing additional information about a scene compared to conventional segmentation techniques. Shadows are used to identify true object edges. The identification of nonoccluded particles is made possible by exploiting the fact that shadows are cast on underlying particles. Implementation issues such as selecting the appropriate colour model and number of illuminations are discussed. Image segmentation using the proposed method, canny edge detection and watershed transform are performed on overlapping beach pebbles and granite. Evaluation results confirm that the proposed method is a successful extension of the original method and reveals its increased accuracy when compared with conventional segmentation techniques.

  10. SIMToolbox: a MATLAB toolbox for structured illumination fluorescence microscopy.

    Science.gov (United States)

    Křížek, Pavel; Lukeš, Tomáš; Ovesný, Martin; Fliegel, Karel; Hagen, Guy M

    2016-01-15

    SIMToolbox is an open-source, modular set of functions for MATLAB equipped with a user-friendly graphical interface and designed for processing two-dimensional and three-dimensional data acquired by structured illumination microscopy (SIM). Both optical sectioning and super-resolution applications are supported. The software is also capable of maximum a posteriori probability image estimation (MAP-SIM), an alternative method for reconstruction of structured illumination images. MAP-SIM can potentially reduce reconstruction artifacts, which commonly occur due to refractive index mismatch within the sample and to imperfections in the illumination. SIMToolbox, example data and the online documentation are freely accessible at http://mmtg.fel.cvut.cz/SIMToolbox. ghagen@uccs.edu Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  11. Topology optimization for optical microlithography with partially coherent illumination

    DEFF Research Database (Denmark)

    Zhou, Mingdong; Lazarov, Boyan Stefanov; Sigmund, Ole

    2017-01-01

    This article revisits a topology optimization design approach for micro-manufacturing and extends it to optical microlithography with partially coherent illumination. The solution is based on a combination of two technologies, the topology optimization and the proximity error correction in microl......This article revisits a topology optimization design approach for micro-manufacturing and extends it to optical microlithography with partially coherent illumination. The solution is based on a combination of two technologies, the topology optimization and the proximity error correction...... in microlithography/nanolithography. The key steps include (i) modeling the physical inputs of the fabrication process, including the ultraviolet light illumination source and the mask, as the design variables in optimization and (ii) applying physical filtering and heaviside projection for topology optimization...

  12. 'No blue' LED solution for photolithography room illumination

    DEFF Research Database (Denmark)

    Ou, Haiyan; Corell, Dennis Dan; Dam-Hansen, Carsten

    2010-01-01

    This paper explored the feasibility of using a LED-based bulb as the illumination light source for photolithography room. A no-blue LED was designed, and the prototype was fabricated. The spectral power distribution of both the LED bulb and the yellow fluorescent tube was measured. Based on that...... color rendering ability than the YFT. Furthermore, LED solution has design flexibility to improve it further. The prototype has been tested with photoresist SU8-2005. Even after 15 days of illumination, no effect was observed. So this LED-based solution was demonstrated to be a very promising light...... source for photolithography room illumination due to its better color rendering in addition to energy efficiency, long life time and design flexibility....

  13. Illumination-parameter adjustable and illumination-distribution visible LED helmet for low-level light therapy on brain injury

    Science.gov (United States)

    Wang, Pengbo; Gao, Yuan; Chen, Xiao; Li, Ting

    2016-03-01

    Low-level light therapy (LLLT) has been clinically applied. Recently, more and more cases are reported with positive therapeutic effect by using transcranial light emitting diodes (LEDs) illumination. Here, we developed a LLLT helmet for treating brain injuries based on LED arrays. We designed the LED arrays in circle shape and assembled them in multilayered 3D printed helmet with water-cooling module. The LED arrays can be adjust to touch the head of subjects. A control circuit was developed to drive and control the illumination of the LLLT helmet. The software portion provides the control of on and off of each LED arrays, the setup of illumination parameters, and 3D distribution of LLLT light dose in human subject according to the illumination setups. This LLLT light dose distribution was computed by a Monte Carlo model for voxelized media and the Visible Chinese Human head dataset and displayed in 3D view at the background of head anatomical structure. The performance of the whole system was fully tested. One stroke patient was recruited in the preliminary LLLT experiment and the following neuropsychological testing showed obvious improvement in memory and executive functioning. This clinical case suggested the potential of this Illumination-parameter adjustable and illuminationdistribution visible LED helmet as a reliable, noninvasive, and effective tool in treating brain injuries.

  14. Variation among Species in the Temperature Dependence of the Reappearance of Variable Fluorescence following Illumination.

    Science.gov (United States)

    Burke, J J

    1990-06-01

    The relationship between the thermal dependence of the reappearance of chlorophyll variable fluorescence following illumination and temperature dependence of the apparent Michaelis constant (K(m)) of NADH hydroxypyruvate reductase for NADH was investigated in cool and warm season plant species. Brancker SF-20 and SF-30 fluorometers were used to evaluate induced fluorescence transients from detached leaves of wheat (Triticum aestivum L. cv TAM-101), cotton (Gossypium hirsutum L. cv Paymaster 145), tomato (Lycopersicon esculentum cv Del Oro), bell pepper (Capsicum annuum L. cv California Wonder), and petunia (Petunia hybrida cv. Red Sail). Following an illumination period at 25 degrees C, the reappearance of variable fluorescence during a dark incubation was determined at 5 degrees C intervals from 15 degrees C to 45 degrees C. Variable fluorescence recovery was normally distributed with the maximum recovery observed at 20 degrees C in wheat, 30 degrees C in cotton, 20 degrees C to 25 degrees C in tomato, 30 to 35 degrees C in bell pepper and 25 degrees C in petunia. Comparison of the thermal response of fluorescence recovery with the temperature sensitivity of the apparent K(m) of hydroxypyruvate reductase for NADH showed that the range of temperatures providing fluorescence recovery corresponded with those temperatures providing the minimum apparent K(m) values (viz. the thermal kinetic window).

  15. Cycles of circadian illuminance are sufficient to entrain and maintain circadian locomotor rhythms in Drosophila

    Science.gov (United States)

    Cho, Eunjoo; Oh, Ji Hye; Lee, Euna; Do, Young Rag; Kim, Eun Young

    2016-11-01

    Light at night disrupts the circadian clock and causes serious health problems in the modern world. Here, we show that newly developed four-package light-emitting diodes (LEDs) can provide harmless lighting at night. To quantify the effects of light on the circadian clock, we employed the concept of circadian illuminance (CIL). CIL represents the amount of light weighted toward the wavelengths to which the circadian clock is most sensitive, whereas visual illuminance (VIL) represents the total amount of visible light. Exposure to 12 h:12 h cycles of white LED light with high and low CIL values but a constant VIL value (conditions hereafter referred to as CH/CL) can entrain behavioral and molecular circadian rhythms in flies. Moreover, flies re-entrain to phase shift in the CH/CL cycle. Core-clock proteins are required for the rhythmic behaviors seen with this LED lighting scheme. Taken together, this study provides a guide for designing healthful white LED lights for use at night, and proposes the use of the CIL value for estimating the harmful effects of any light source on organismal health.

  16. Evaluation of Optically Illuminated Mosfet Characteristics by Tcad Simulation

    Directory of Open Access Journals (Sweden)

    Prerana Jain

    2013-04-01

    Full Text Available In this paper we report effect of optical illumination on Silicon MOSFET. The MOSFET has been studied in respect of current voltage, transconductance admittance and scattering parameters. Gain analysis of the Silicon MOSFET is done in dark and under optical illumination. The device is fabricated using ATHENA™ process simulator and the device simulation is performed using ATLAS™ from SILVACO international. The simulation results indicate potential of MOSFET as optically sensitive structure which can be used for increase in data transmission/reception rates, reduction of interconnect delays, elimination of clock skew, or as a photodetector for optoelectronic applications at low and radio frequency.

  17. Dental operating lights and illumination of the dental surgery.

    Science.gov (United States)

    Viohl, J

    1979-06-01

    The requirements laid down in national and international standards and draft standards provide helpful guidelines for optimum illumination (Fig. 1, Table I). General room illumination with 500 lx and illumination of the working area with 1000 lx are best achieved with a larger number of fluorescent lamps on the ceiling above and in front of the dental chair. Daylight white lamps with good colour rendering (e.g. Osram colour 19 or Philips colour 47) are a good combination with changing daylight and the colour of light of the operating light. The colour of external skin, mucous membrane and teeth appears natural. The eight surgical lights examined differ in quality (Figs. 2-9). The maximum illuminance is between 9000 and 21 000 lx and is thus sufficiently high. The evenness of light distribution within an ellipse 9 cm and 18 cm in diameter is between 1 : 4 and 1 : 15 (Figs. 10 and 11). Illuminance can be adjusted to the work in hand by means of controls. If the patient looks into the operating lights (Figs. 2c and 9c), maximum luminances of 5 cd/cm2-20 cd/cm2 occur 8 cm above the illuminance maximum in six operating lights. Luminances of more than 20 cd/cm2 cause squinting and running eyes. A light fitting with more than 200 cd/cm2 should not be used. A sharp fall in illuminance (distinct light/dark threshold) and low luminances to the patient's eyes can be achieved with very directed light. Very directed light leads to very heavy shadows. Similarly, less specifically directed light leads to softer shadows so that objects in the oral cavity can be discerned easily, but the patient is no longer dazzled. The following operating lights can be recommended if the patient is to suffer as little glare as possible: Den-Tel-Ez Daray, and Belmont Type 040, Faro Sunlight S 70, Ritter Super Starlite; as well as: Chirana Fax, Siemens Sirolux. The following can be recommended for good illumination of the oral cavity: Belmont Type 040, Chirana Fax, Emda Top Spot, Faro Sunlight S 70

  18. Illumination Compensation Algorithm for Unevenly Lighted Document Segmentation

    Directory of Open Access Journals (Sweden)

    Ju Zhiyong

    2013-07-01

    Full Text Available For the problem of segmenting the unevenly lighted document image, this paper proposes an illumination compensation segmentation algorithm which can effectively segment the unevenly lighted document. The illumination compensation method is proposed to equivalently convert unevenly lighted document image to evenly lighted document image, then segment the evenly lighted document directly. Experimental results show that the proposed method can get the accurate evenly lighted document images so that we can segment the document accurately and it is more efficient to process unevenly lighted document  images than traditional binarization methods. The algorithm effectively overcomes the difficulty in handling uneven lighting and enhances segmentation quality considerably.

  19. Estimating Outdoor Illumination Conditions Based on Detection of Dynamic Shadows

    DEFF Research Database (Denmark)

    Madsen, Claus B.; Lal, Brajesh Behari

    2013-01-01

    The paper proposes a technique for estimation outdoor illumination conditions in terms of sun and sky radiances directly from pixel values of dynamic shadows detected in video sequences produved by a commercial stereo camera. The technique is applied to the rendering of virtual object into the im......The paper proposes a technique for estimation outdoor illumination conditions in terms of sun and sky radiances directly from pixel values of dynamic shadows detected in video sequences produved by a commercial stereo camera. The technique is applied to the rendering of virtual object...

  20. Drift of rigidly rotating spirals under periodic and noisy illuminations.

    Science.gov (United States)

    Zhang, Hong; Wu, Ning-Jie; Ying, He-Ping; Hu, Gang; Hu, Bambi

    2004-10-15

    Under the weak deformation approximation, the motion of rigidly rotating spirals induced by periodic and noisy illuminations are investigated analytically. We derive an approximate but explicit formula of the spiral drift velocity directly from the original reaction-diffusion equation. With this formula we are able to explain the main features in the periodic and noisy illuminations induced spiral drift problems. Numerical computations of the Oregonator model are carried out as well, and they agree with the main qualitative conclusions of our analytical results.

  1. 3D Imaging with Structured Illumination for Advanced Security Applications

    Energy Technology Data Exchange (ETDEWEB)

    Birch, Gabriel Carisle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dagel, Amber Lynn [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kast, Brian A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Smith, Collin S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Three-dimensional (3D) information in a physical security system is a highly useful dis- criminator. The two-dimensional data from an imaging systems fails to provide target dis- tance and three-dimensional motion vector, which can be used to reduce nuisance alarm rates and increase system effectiveness. However, 3D imaging devices designed primarily for use in physical security systems are uncommon. This report discusses an architecture favorable to physical security systems; an inexpensive snapshot 3D imaging system utilizing a simple illumination system. The method of acquiring 3D data, tests to understand illumination de- sign, and software modifications possible to maximize information gathering capability are discussed.

  2. Object wave reconstruction by speckle illumination and phase retrieval

    DEFF Research Database (Denmark)

    Almoro, Percival; Hanson, Steen Grüner

    2009-01-01

    An innovative setup for the speckle-based phase retrieval method is proposed. In the conventional setup, a plane wave illuminates the test object and the transmitted wavefront is incident on a diffuser aperture generating a speckle field. The sampled speckle intensities at axially displaced planes...... are input into a phase retrieval algorithm based on a wave propagation equation. In the new setup, the arrangement of the diffuser and the object is reversed. A plane wave incident on the diffuser generates a speckle field which, in turn, is used to illuminate the object. The transmitted wavefront...

  3. Wide-field optical nanoprofilometry using structured illumination.

    Science.gov (United States)

    Wang, Chun-Chieh; Lee, Kuang-Li; Lee, Chau-Hwang

    2009-11-15

    We combine the differential height measurement concept with structured illumination microscopy to develop wide-field optical nanoprofilometry. Sub-diffraction-limit lateral resolution and axially sectioning imaging are achieved with structured illumination using a liquid-crystal spatial light modulator. As the sample surface is placed into the linear region of the sectioning axial response curve, the signal change owing to topographic variations provides nanometer depth sensitivity. The lateral resolution and the depth profiling accuracy are about 0.3 wavelengths and 6 nm, respectively. Depth profiling on solid-state specimens and label-free superresolution imaging of living cells are demonstrated.

  4. Freeform microstructure linear light emitter design for a natural light illumination system.

    Science.gov (United States)

    Chen, Bo-Jian; Gao, Bo-Yuan; Ullah, Irfan; Chen, Kuan-Yu; Chou, Chun-Han; Lin, Chia-Min; Chang, Cheng-Ming; Jhan, Kai-Cyuan; Whang, Allen Jong-Woei

    2015-10-01

    The major factors of an illuminative environment are a high rendering index and uniformity. The natural light illumination system (NLIS) is used to guide sunlight for indoor illumination. The NLIS consists of three subsystems: collecting, transmitting, and emitting. Nowadays, a variety of light emitters are available for different illuminative environments. This paper proposes a linear microstructure to diffuse parallel light for indoor illumination. To increase uniformity and promote the illuminative area, the light emitter includes two microstructures for the distribution of light. Finally, the proposed light emitter gives illuminance uniformity and efficiency of 0.55% and 74.18%, respectively.

  5. Improving color correction across camera and illumination changes by contextual sample selection

    Science.gov (United States)

    Wannous, Hazem; Lucas, Yves; Treuillet, Sylvie; Mansouri, Alamin; Voisin, Yvon

    2012-04-01

    In many tasks of machine vision applications, it is important that recorded colors remain constant, in the real world scene, even under changes of the illuminants and the cameras. Contrary to the human vision system, a machine vision system exhibits inadequate adaptability to the variation of lighting conditions. Automatic white balance control available in commercial cameras is not sufficient to provide reproducible color classification. We address this problem of color constancy on a large image database acquired with varying digital cameras and lighting conditions. A device-independent color representation may be obtained by applying a chromatic adaptation transform, from a calibrated color checker pattern included in the field of view. Instead of using the standard Macbeth color checker, we suggest selecting judicious colors to design a customized pattern from contextual information. A comparative study demonstrates that this approach ensures a stronger constancy of the colors-of-interest before vision control thus enabling a wide variety of applications.

  6. Is There a Cosmological Constant?

    Science.gov (United States)

    Kochanek, Christopher

    2002-07-01

    The grant contributed to the publication of 18 refereed papers and 5 conference proceedings. The primary uses of the funding have been for page charges, travel for invited talks related to the grant research, and the support of a graduate student, Charles Keeton. The refereed papers address four of the primary goals of the proposal: (1) the statistics of radio lenses as a probe of the cosmological model (#1), (2) the role of spiral galaxies as lenses (#3), (3) the effects of dust on statistics of lenses (#7, #8), and (4) the role of groups and clusters as lenses (#2, #6, #10, #13, #15, #16). Four papers (#4, #5, #11, #12) address general issues of lens models, calibrations, and the relationship between lens galaxies and nearby galaxies. One considered cosmological effects in lensing X-ray sources (#9), and two addressed issues related to the overall power spectrum and theories of gravity (#17, #18). Our theoretical studies combined with the explosion in the number of lenses and the quality of the data obtained for them is greatly increasing our ability to characterize and understand the lens population. We can now firmly conclude both from our study of the statistics of radio lenses and our survey of extinctions in individual lenses that the statistics of optically selected quasars were significantly affected by extinction. However, the limits on the cosmological constant remain at lambda sigma confidence level, which is in mild conflict with the results of the Type la supernova surveys. We continue to find that neither spiral galaxies nor groups and clusters contribute significantly to the production of gravitational lenses. The lack of group and cluster lenses is strong evidence for the role of baryonic cooling in increasing the efficiency of galaxies as lenses compared to groups and clusters of higher mass but lower central density. Unfortunately for the ultimate objective of the proposal, improved constraints on the cosmological constant, the next large survey

  7. Evaluation of Satellite Image Correction Methods Caused by Differential Terrain Illumination

    Directory of Open Access Journals (Sweden)

    Purnama Budi Santosa

    2016-08-01

    Full Text Available The problem due to differential terrain illumination on satellite imagery is experienced by most of areas which are on mountainous terrain. This may cause variations in reflectance of similar ground features which lead to a misclassification of land cover classes due to different topographic positions. This phenomenon most commonly occurred in the areas which are located on southern and northern hemisphere because of the low sun inclination. This problem has been a major interest for researchers to be solved prior to the land cover classification process. For satellite images which experience this kind of problem, topographic correction need to be applied in order to reduce the illumination effects prior to land cover classification process. This research is aimed at conducting topographic correction of multi spectral SPOT satellite data as well as evaluating the three topographic correction methods. They are Cosine which is based on Lambertian reflectance assumption, as well as Minnaert correction and C correction methods which are based on non-Lambertian reflectance assumption. The data used in this study are two scenes of SPOT images of forested mountainous area of Miyazaki Prefecture, Kyushu, Japan. Research steps had been conducted in this study including geometric correction, sample data collection for calculating Minnaert constants and C constants at location which represents the whole study area, topographic correction for two scenes SPOT images, and results analysis. The results show that Cosine method did not show good performance for the study area which is topographically dominated by rugged terrain. Whereas Minnaert method and C method gave satisfactory results as is indicated by the statistical data as well as visual interpretation. However the Minnaert correction method showed slightly better performance than the C correction method.

  8. Is There a Cosmological Constant?

    Science.gov (United States)

    Kochanek, Christopher; Oliversen, Ronald J. (Technical Monitor)

    2002-01-01

    The grant contributed to the publication of 18 refereed papers and 5 conference proceedings. The primary uses of the funding have been for page charges, travel for invited talks related to the grant research, and the support of a graduate student, Charles Keeton. The refereed papers address four of the primary goals of the proposal: (1) the statistics of radio lenses as a probe of the cosmological model (#1), (2) the role of spiral galaxies as lenses (#3), (3) the effects of dust on statistics of lenses (#7, #8), and (4) the role of groups and clusters as lenses (#2, #6, #10, #13, #15, #16). Four papers (#4, #5, #11, #12) address general issues of lens models, calibrations, and the relationship between lens galaxies and nearby galaxies. One considered cosmological effects in lensing X-ray sources (#9), and two addressed issues related to the overall power spectrum and theories of gravity (#17, #18). Our theoretical studies combined with the explosion in the number of lenses and the quality of the data obtained for them is greatly increasing our ability to characterize and understand the lens population. We can now firmly conclude both from our study of the statistics of radio lenses and our survey of extinctions in individual lenses that the statistics of optically selected quasars were significantly affected by extinction. However, the limits on the cosmological constant remain at lambda Labor and Munoz).

  9. A Variant of Davenport's Constant

    Indian Academy of Sciences (India)

    R Thangadurai

    2007-05-01

    Let be a prime number. Let be a finite abelian -group of exponent (written additively) and be a non-empty subset of $]n[:=\\{1,2,\\ldots,n\\}$ such that elements of are incongruent modulo and non-zero modulo . Let $k ≥ D(G)/|A|$ be any integer where () denotes the well-known Davenport’s constant. In this article, we prove that for any sequence $g_1,g_2,\\ldots,g_k$ (not necessarily distinct) in , one can always extract a subsequence $g_{i_1},g_{i_2},\\ldots,g_{i_l}$ with $1 ≤ l ≤ k$ such that $$\\sum\\limits_{j=1}^l a_j g_{i_j}=0 \\text{in} G,$$ where $a_j\\in A$ for all . We provide examples where this bound cannot be improved. Furthermore, for the cyclic groups, we prove some sharp results in this direction. In the last section, we explore the relation between this problem and a similar problem with prescribed length. The proof of Theorem 1 uses group-algebra techniques, while for the other theorems, we use elementary number theory techniques.

  10. Review of the illumination problems pertaining to South African collieries.

    CSIR Research Space (South Africa)

    Pardoe, DR

    1994-01-01

    Full Text Available In 1992, a proposal was submitted to SIMRAC for a two year programme of work with the overall objective of conducting a general review of problems and techniques related to underground colliery illumination, particular emphasis on identifying means...

  11. All-solution processed organic solar cells with top illumination

    NARCIS (Netherlands)

    Patil, B.R.; Shanmugam, S.; Teunissen, J.P.; Galagan, Y.

    2015-01-01

    All-solution processed organic solar cells with inverted device architecture were demonstrated. Devices contain opaque bottom electrodes and semitransparent top electrodes, resulting in top illuminated devices. Nanoparticles-based Ag ink was used for inkjet printing both top and bottom electrodes.

  12. Blind fluorescence structured illumination microscopy: A new reconstruction strategy

    CERN Document Server

    Labouesse, S; Idier, J; Bourguignon, S; Liu, P; Sentenac, A

    2016-01-01

    In this communication, a fast reconstruction algorithm is proposed for fluorescence \\textit{blind} structured illumination microscopy (SIM) under the sample positivity constraint. This new algorithm is by far simpler and faster than existing solutions, paving the way to 3D and/or real-time 2D reconstruction.

  13. Adding Expressiveness to Smartwatch Notifications Through Ambient Illumination:

    DEFF Research Database (Denmark)

    Kerber, Frederic; Gehring, Sven; Krüger, Antonio

    2017-01-01

    by providing an aggregation and filtering approach to better handle notifications. Furthermore, they investigated several display concepts based on a self-built smartwatch prototype equipped with twelve full-color LEDs to present notifications through ambient illumination. Derived from a user study with twelve...

  14. Modeling quantitative phase image formation under tilted illuminations.

    Science.gov (United States)

    Bon, Pierre; Wattellier, Benoit; Monneret, Serge

    2012-05-15

    A generalized product-of-convolution model for simulation of quantitative phase microscopy of thick heterogeneous specimen under tilted plane-wave illumination is presented. Actual simulations are checked against a much more time-consuming commercial finite-difference time-domain method. Then modeled data are compared with experimental measurements that were made with a quadriwave lateral shearing interferometer.

  15. Super-resolution thermographic imaging using blind structured illumination

    Science.gov (United States)

    Burgholzer, Peter; Berer, Thomas; Gruber, Jürgen; Mayr, Günther

    2017-07-01

    Using an infrared camera for thermographic imaging allows the contactless temperature measurement of many surface pixels simultaneously. From the measured surface data, the structure below the surface, embedded inside a sample or tissue, can be reconstructed and imaged, if heated by an excitation light pulse. The main drawback in active thermographic imaging is the degradation of the spatial resolution with the imaging depth, which results in blurred images for deeper lying structures. We circumvent this degradation by using blind structured illumination combined with a non-linear joint sparsity reconstruction algorithm. We demonstrate imaging of a line pattern and a star-shaped structure through a 3 mm thick steel sheet with a resolution four times better than the width of the thermal point-spread-function. The structured illumination is realized by parallel slits cut in an aluminum foil, where the excitation coming from a flashlight can penetrate. This realization of super-resolution thermographic imaging demonstrates that blind structured illumination allows thermographic imaging without high degradation of the spatial resolution for deeper lying structures. The groundbreaking concept of super-resolution can be transferred from optics to diffusive imaging by defining a thermal point-spread-function, which gives the principle resolution limit for a certain signal-to-noise ratio, similar to the Abbe limit for a certain optical wavelength. In future work, the unknown illumination pattern could be the speckle pattern generated by a short laser pulse inside a light scattering sample or tissue.

  16. Numerical correction of aberrations via phase retrieval with speckle illumination

    DEFF Research Database (Denmark)

    Almoro, Percival; Gundu, Phanindra Narayan; Hanson, Steen Grüner

    2009-01-01

    What we believe to be a novel technique for wavefront aberration measurement using speckle patterns is presented. The aberration correction is done numerically. A tilted lens is illuminated with a partially developed speckle field, and the transmitted light intensity is sampled at axially displaced...

  17. Studies in Natural Illumination in Schoolrooms. Part III

    Science.gov (United States)

    1929-11-01

    PI"C HEALTH BULLIN No. 188 STUDIESJIN ATURA ILUMINATION IN SCHOOLROOMSA f1-~7~PART III 20 U. 0 49990809 433 UngimED STATES ý-REASURY DE~PART1WENT... ilumination ratio of desk No. 14 for each month and hour of observation ---------------------------------------------- 55 29. Mean illumination ratio of desk

  18. Illumination Invariant Face Recognition using SQI and Weighted LBP Histogram

    Directory of Open Access Journals (Sweden)

    Mohsen Biglari

    2014-12-01

    Full Text Available Face recognition under uneven illumination is still an open problem. One of the main challenges in real-world face recognition systems is illumination variation. In this paper, a novel illumination invariant face recognition approach base on Self Quotient Image (SQI and weighted Local Binary Pattern (WLBP histogram has been proposed. In this system, the performance of the system is increased by using different sigma values of SQI for training and testing. Furthermore, using two multi-region uniform LBP operators for feature extraction simultaneously, made the system more robust to illumination variation. This approach gathers information of the image in different local and global levels. The weighted Chi square statistic is used for histogram comparison and NN (1-NN is used as classifier. The weighted approach emphasizes on the more important regions in the faces. The proposed approach is compared with some new and traditional methods like QI, SQI, QIR, MQI, DMQI, DSFQI, PCA and LDA on Yale face database B and CMU-PIE database. The experimental results show that the proposed method outperforms other tested methods.

  19. 36 CFR 910.38 - Building exterior illumination.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Building exterior illumination. 910.38 Section 910.38 Parks, Forests, and Public Property PENNSYLVANIA AVENUE DEVELOPMENT... specified in the Pennsylvania Avenue Lighting Plan of the Corporation. ...

  20. All-solution processed organic solar cells with top illumination

    NARCIS (Netherlands)

    Patil, B.R.; Shanmugam, S.; Teunissen, J.P.; Galagan, Y.

    2015-01-01

    All-solution processed organic solar cells with inverted device architecture were demonstrated. Devices contain opaque bottom electrodes and semitransparent top electrodes, resulting in top illuminated devices. Nanoparticles-based Ag ink was used for inkjet printing both top and bottom electrodes. S

  1. Interactive Global Illumination Effects Using Deterministically Directed Layered Depth Maps

    DEFF Research Database (Denmark)

    Aalund, F. P.; Frisvad, Jeppe Revall; Bærentzen, Jakob Andreas

    2015-01-01

    A layered depth map is an extension of the well-known depth map used in rasterization. Multiple layered depth maps can be used as a coarse scene representation. We develop two global illumination methods which use said scene representation. The first is an interactive ambient occlusion method...

  2. Book Design, Part III: Illuminated Letters and Borders.

    Science.gov (United States)

    Harms, Jeanne McLain; Lettow, Lucille

    1997-01-01

    This third in a series of articles on book design discusses and illustrates elements found within the body of the work: (1) illuminated letters, which serve as decoration, reflect cultural elements, enhance the meaning of text and illustrations, or establish motif, setting, or theme; and (2) borders, which serve as frames for text and…

  3. On calculating metamer sets for spectrally tunable LED illuminators.

    Science.gov (United States)

    Finlayson, Graham; Mackiewicz, Michal; Hurlbert, Anya; Pearce, Bradley; Crichton, Stuart

    2014-07-01

    Solid state lighting is becoming a popular light source for color vision experiments. One of the advantages of light emitting diodes (LEDs) is the possibility to shape the target light spectrum according to the experimenter's needs. In this paper, we present a method for creating metameric lights with an LED-based spectrally tunable illuminator. The equipment we use consists of six Gamma Scientific RS-5B lamps, each containing nine different LEDs and a 1 m integrating sphere. We provide a method for describing the (almost) entire set of illuminant metamers. It will be shown that the main difficulty in describing this set arises as the result of the intensity dependent peak-wavelength shift, which is manifested by the majority of the LEDs used by the illuminators of this type. We define the normalized metamer set describing all illuminator spectra that colorimetrically match a given chromaticity. Finally, we describe a method for choosing the smoothest or least smooth metamer from the entire set.

  4. Analysis of confocal microscopy under ultrashort light-pulse illumination

    Energy Technology Data Exchange (ETDEWEB)

    Kempe, M.; Rudolph, W. (Univ. of New Mexico, Albuquerque (United States))

    1993-02-01

    The resolution of confocal laser scanning microscopes is analyzed if they are used in measurements that are to combine high spatial and high temporal resoltuion. A generalized Fourier-optical treatment is developed in which the system characteristics contain all necessary information regarding the optical arrangement and the illuminating light pulses. Coherent and incoherent imaging are considered in detail. 10 refs., 8 figs.

  5. Illumination conditions of the lunar polar regions using LOLA topography

    Science.gov (United States)

    Mazarico, E.; Neumann, G. A.; Smith, D. E.; Zuber, M. T.; Torrence, M. H.

    2011-02-01

    We use high-resolution altimetry data obtained by the Lunar Orbiter Laser Altimeter instrument onboard the Lunar Reconnaissance Orbiter to characterize present illumination conditions in the polar regions of the Moon. Compared to previous studies, both the spatial and temporal extent of the simulations are increased significantly, as well as the coverage (fill ratio) of the topographic maps used, thanks to the 28 Hz firing rate of the five-beam instrument. We determine the horizon elevation in a number of directions based on 240 m-resolution polar digital elevation models reaching down to ˜75° latitude. The illumination of both polar regions extending to ˜80° can be calculated for any geometry from those horizon longitudinal profiles. We validated our modeling with recent Lunar Reconnaissance Orbiter Wide-Angle Camera images. We assessed the extent of permanently shadowed regions (PSRs, defined as areas that never receive direct solar illumination), and obtained total areas generally larger than previous studies (12,866 and 16,055 km 2, in the north and south respectively). We extended our direct illumination model to account for singly-scattered light, and found that every PSR does receive some amount of scattered light during the year. We conducted simulations over long periods (several 18.6-years lunar precession cycles) with a high temporal resolution (6 h), and identified the most illuminated locations in the vicinity of both poles. Because of the importance of those sites for exploration and engineering considerations, we characterized their illumination more precisely over the near future. Every year, a location near the Shackleton crater rim in the south polar region is sunlit continuously for 240 days, and its longest continuous period in total darkness is about 1.5 days. For some locations small height gains (˜10 m) can dramatically improve their average illumination and reduce the night duration, rendering some of those particularly attractive

  6. The fundamental constants and quantum electrodynamics

    CERN Document Server

    Taylor, Barry N; Langenberg, D N

    1969-01-01

    Introduction ; review of experimental data ; least-squares adjustment to obtain values of the constants without QED theory ; implications for quantum electrodynamics ; final recommended set of fundamental constants ; summary and conclusions.

  7. Temporal variation of coupling constants and nucleosynthesis

    CERN Document Server

    Oberhummer, Heinz; Fairbairn, M; Schlattl, H; Sharma, M M

    2003-01-01

    We investigate the triple-alpha process and the Oklo phenomenon to obtain constraints on possible cosmological time variations of fundamental constants. Specifically we study cosmological temporal constraints for the fine structure constant and nucleon and meson masses.

  8. Capacitive Cells for Dielectric Constant Measurement

    Science.gov (United States)

    Aguilar, Horacio Munguía; Maldonado, Rigoberto Franco

    2015-01-01

    A simple capacitive cell for dielectric constant measurement in liquids is presented. As an illustrative application, the cell is used for measuring the degradation of overheated edible oil through the evaluation of their dielectric constant.

  9. Temporal variation of coupling constants and nucleosynthesis

    Science.gov (United States)

    Oberhummer, H.; Csótó, A.; Fairbairn, M.; Schlattl, H.; Sharma, M. M.

    2003-05-01

    We investigate the triple-alpha process and the Oklo phenomenon to obtain constraints on possible cosmological time variations of fundamental constants. Specifically we study cosmological temporal constraints for the fine structure constant and nucleon and meson masses.

  10. Capacitive Cells for Dielectric Constant Measurement

    Science.gov (United States)

    Aguilar, Horacio Munguía; Maldonado, Rigoberto Franco

    2015-01-01

    A simple capacitive cell for dielectric constant measurement in liquids is presented. As an illustrative application, the cell is used for measuring the degradation of overheated edible oil through the evaluation of their dielectric constant.

  11. Critical survey of stability constants of EDTA complexes critical evaluation of equilibrium constants in solution stability constants of metal complexes

    CERN Document Server

    Anderegg, G

    2013-01-01

    Critical Survey of Stability Constants of EDTA Complexes focuses on the computations, values, and characteristics of stability constants. The book emphasizes that for a critical discussion of experimentally determined stability constants, it is important to consider the precision of the values that manifests the self-consistency of the constant, taking into consideration the random errors. The publication reviews the stability constants of metal complexes. The numerical calculations affirm the reactions and transformations of metal ions when exposed to varying conditions. The text also present

  12. Transillumination spatially modulated illumination microscopy for human chromosome imaging

    Science.gov (United States)

    Pitris, Costas; Heracleous, Peter; Patsalis, Philippos

    2005-03-01

    Human chromosome analysis is an essential task in cytogenetics, especially in prenatal screening, genetic syndrome diagnosis, cancer pathology research and mutagen dosimetry. Chromosomal analysis begins with the creation of a karyotype, which is a layout of chromosome images organized by decreasing size in pairs. Both manual and automatic classification of chromosomes are limited by the resolution of the microscope and imaging system used. One way to improve the results of classification and even detect subtleties now remaining undetected, is to enhance the resolution of the images. It is possible to achieve lateral resolution beyond the classical limit, by using spatially modulated illumination (SMI) in a wide-field, non-confocal microscope. In this case, the sample is illuminated with spatially modulated light, which makes normally inaccessible high-resolution information visible in the observed image by shifting higher frequencies within the OTF limits of the microscope. Although, SMI microscopes have been reported in the past, this manuscript reports the development of a transillumination microscope for opaque, non-fluorescent samples. The illumination path consisted of a light source illuminating a ruled grating which was subsequently imaged on the sample. The grating was mounted on a rotating and translating stage so that the magnification and rotation of the pattern could be adjusted. The imaging lens was a 1.25 NA oil immersion objective. Test samples showed resolution improvement, as judged from a comparison of the experimentally obtained FWHM. Further studies using smaller fringe distance or laser interference pattern illumination will be evaluated to further optimize the SMI results.

  13. Estimation of solar illumination time on the earth by an analytical model: a fertile scenery for to teach physics

    OpenAIRE

    Talero, Paco; Santana, Fernanda; Mora, César

    2012-01-01

    We proposed an analytical model for the calculus of illumination time of the Earth for any time of year and any latitude, this model assumes the obliquity of the ecliptic as constant, the light beams as parallels, the Earth as spherical, the movement of translation of Earth as uniform circular, also this model showed a context of the astronomy whereby the teachers can teach the basic physics.It was built through a relationship between the movement of translation and of rotation of the wave fr...

  14. Untangling Fixed Effects and Constant Regressors

    NARCIS (Netherlands)

    Klaassen, F.; Teulings, R.

    2015-01-01

    Fixed effects (FE) in panel data models overlap each other and prohibit the identification of the impact of "constant" regressors. Think of regressors that are constant across countries in a country-time panel with time FE. The traditional approach is to drop some FE and constant regressors by

  15. Searching for Kaprekar's constants: algorithms and results

    Directory of Open Access Journals (Sweden)

    Byron L. Walden

    2005-01-01

    Full Text Available We examine some new results on Kaprekar's constants, specifically establishing the unique 7-digit (in base 4 and 9-digit (in base 5 Kaprekar's constants and showing that there are no 15-, 21-, 27-, or 33-digit Kaprekar's constants.

  16. Untangling Fixed Effects and Constant Regressors

    NARCIS (Netherlands)

    Klaassen, F.; Teulings, R.

    2015-01-01

    Fixed effects (FE) in panel data models overlap each other and prohibit the identification of the impact of "constant" regressors. Think of regressors that are constant across countries in a country-time panel with time FE. The traditional approach is to drop some FE and constant regressors by norma

  17. Illumination distribution and signal transmission for indoor visible light communication with different light-emitting diode arrays and pre-equality circuits

    Science.gov (United States)

    Chen, Hsi-Chao; Liou, Cheng-Jyun; Siao, Syuan-Ruei

    2015-11-01

    The purpose of this study was to seek the optimal design for light-emitting diode (LED) arrays and pre-equality circuits in indoor visible lighting illumination combined with communication. The optical and communicational properties of illumination distribution and signal transmission were investigated. These illumination distributions of array sources were derivate and simulated and actually can be used in free-space communication. Simulated results show the total flux size was rectangle>radial>circlearray, and real measurements also showed the total flux was rectangle>radial>circlearray. The simulated and measured results have a similarity of over 98% by normalized cross correlation. In addition, when the distance of the installed lamp from the wall was 1 m, the rectangular array had the best illumination uniformity of 77.24%, and the size of uniformity was the rectangle>radial≈circle array. Finally, the gain and constant-current pre-equality circuits were used in free-space communication with a carrier frequency from 1 KHz to 1 MHz at a distance of 1.8 m. Both the received signal intensity and divergence angle were rectangle>radial>circle array. The constant-current pre-equality circuit could add the divergence angle from ±18.6 deg to ±36.68 deg in the rectangle array at a carrier frequency of 1 MHz.

  18. Influence of UV illumination on track etching process%UV照射对径迹蚀刻过程的影响

    Institute of Scientific and Technical Information of China (English)

    LIU Qi; ZHU Zhiyong; Maekawa Yasunari; Yoshida Masaru; YAO Side

    2005-01-01

    Truck technology depends decisively on the track structure of the material after irradiation. In order to reveal microstructures of the ion-tracks, many techniques have been applied to characterize the track. Conductometrie method is wildly used in the area as it can monitor in-situ the pore formation and growth processes that are closely related to structures of the ion track[1].In this study, polyethylterephthalate films (PET, 38 μm thick) were irradiated with Xe ions of 450 MeV, 3 × 105ions/cm2. Before etching with aqueous 0.3 M NaOH solution at 40℃, the samples were illuminated with UV light (λ>310nm) in air for different time durations. Pore growth processes during the etching were monitored by the conductometric measurement. Fig. 1 shows the measurement results of radial etching rate of the pore growth in dGl/2/dt (Ω-1/2s-1) with the etching time.a. Without UV illumination, b. UV illuminated for 60 min, c. UV illuminated for 180 min, d. UV illuminated for 720 min As shown in Fig. 1, the etching processes changed dramatically with UV illumination time. (1) The break through time reduced with increased sensitization time, from 8× 104S of the control to about 1 × 104s of the 720 minutes UV illumination. (2) With increased UV illumination time, the shape of the pore growth rate curve changed greatly, f-mally became a shape with a peak and a vale. Formation of the peak implies that pores tended to break-through on completing the UV-light illumination, whereas the vale can be related to the slower etching rate in the track halo where most molecules had been crosslinked by the heavy ion irradiation. After etching for sufficient long time, the pore grew at a constant rate determined by the bulk etching rate.To interpret the measurements, numerical analysis and fitting were carried out, from which information related to the track structures and variations with the UV illumination was obtained.

  19. Autofluorescence dynamics during reperfusion following long-term renal ischemia in a rat model

    Energy Technology Data Exchange (ETDEWEB)

    Raman, R N; Pivetti, C D; Matthews, D L; Troppmann, C; Demos, S G

    2008-02-08

    Optical properties of near-surface kidney tissue were monitored in order to assess response during reperfusion to long (20 minutes) versus prolonged (150 minutes) ischemia in an in vivo rat model. Specifically, autofluorescence images of the exposed surfaces of both the normal and the ischemic kidneys were acquired during both injury and reperfusion alternately under 355 nm and 266 nm excitations. The temporal profile of the emission of the injured kidney during the reperfusion phase under 355 nm excitation was normalized to that under 266 nm as a means to account for changes in tissue optical properties independent of ischemia as well as changes in the illumination/collection geometrical parameters in future clinical implementation of this technique using a hand-held probe. The scattered excitation light signal was also evaluated as a reference signal and found to be inadequate. Characteristic time constants were extracted using fit to a relaxation model and found to have larger mean values following 150 minutes of injury. The mean values were then compared with the outcome of a chronic survival study where the control kidney had been removed. Rat kidneys exhibiting longer time constants were much more likely to fail. This may lead to a method to assess kidney viability and predict its ability to recover in the initial period following transplantation or resuscitation.

  20. Measurements of the time constant for steady ionization in shaped-charge barium releases

    Science.gov (United States)

    Hoch, Edward L.; Hallinan, Thomas J.

    1993-01-01

    Quantitative measurements of three solar illuminated shaped-charge barium releases injected at small angles to the magnetic field were made using a calibrated color television camera. Two of the releases were from 1989. The third release, a reanalysis of an event included in Hallinan's 1988 study of three 1986 releases, was included to provide continuity between the two studies. Time constants for ionization, measured during the first 25 s of each release, were found to vary considerably. The two 1989 time constants differed substantially, and both were significantly less than any of the 1986 time constants. On the basis of this variability, we conclude that the two 1989 releases showed evidence of continuous nonsolar ionization. One release showed nonsolar ionization which could not he attributed to Alfven's critical ionization velocity process, which requires a component of velocity perpendicular to the magnetic field providing a perpendicular energy greater than the ionization potential.

  1. Estimation of solar illumination time on the earth by an analytical model: a fertile scenery for to teach physics

    CERN Document Server

    Talero, Paco; Mora, César

    2012-01-01

    We proposed an analytical model for the calculus of illumination time of the Earth for any time of year and any latitude, this model assumes the obliquity of the ecliptic as constant, the light beams as parallels, the Earth as spherical, the movement of translation of Earth as uniform circular, also this model showed a context of the astronomy whereby the teachers can teach the basic physics.It was built through a relationship between the movement of translation and of rotation of the wave front light, then we found the of illumination zone on the Earth and the illumination time is estimated in a particular latitude with the uniform circular movement of Earth. Present model was confronted with the numerical results of the Geoscience Australia Agency and it is found a maxim perceptual error of 1,6%, this value was assigned primarily to the difference between the circular trajectory, in this model, and the elliptical trajectory that is the real. Without the use of spherical trigonometry was obtained an analytic...

  2. Influence of experimental illumination and seasonal variation on crossbreending mating in the snail Biomphalaria Glabrata

    Directory of Open Access Journals (Sweden)

    F. Pimentel-Souza

    1988-03-01

    Full Text Available The crossbreeding activities of the Schistosoma mansoni vector snail Biomphalaria glabrata were counted in a laboratory aquarium throughout the year under two regimes of 12h light: 12h dark from 7 A., M. to 10 P. M. Mating increased significantly in Authmn and Winter and just missed a significant inverse correlation with temperature and a direct one with locomotion. Other similar experiments were carried out to compare mating under various ilumination conditions in complete daily cycle measurements. Mating counts decreased under the regimes which submited snail to a total exposure of 12h light and 12 dark during a daily cycle in the following sequence: 12h light: 12h dark alternating hourly with light gradient, 12h light: 12h dark, 1h light: 1h dark and 12h dark: 12h light. Under two constant illuminations, the mating scored less than under the previous conditions, except under 12h light. Under darkeness the mating count was lower than light conditions. There was no way to differentiate the night and day rhythms of mating on different days in each regime, except for mating under 12h light: 12 dark alternating with light gradient, constant dark and 12h dark: 12h light conditions. Mating increased in certain light and temperature conditions, in wich the intensities, should have an optimum value.

  3. Illumination Compensation for 2-D Barcode Recognition Basing Morphologic

    Directory of Open Access Journals (Sweden)

    Jian-Hua Li

    2013-04-01

    Full Text Available Improvement of image quality has been highly demanded in digital imaging systems. This study presents a novel illumination normalization approach for 2-D barcode recognition under varying lighting conditions. MMs (Morphological transformations are employed to original images using big scale multiple SEs (structuring elements. Then we make use of entropy to fuse images. The performance of proposed methodology is illustrated through the processing of images with different kinds of 2-D barcodes under different backgrounds. The experimental results show that this approach can process different kinds of 2-D barcodes under varying lighting conditions adaptively. Compared with other conventional methods, our proposed approach does a better job in processing 2-D barcode under non-uniform illumination.

  4. Illumination of dense urban areas by light redirecting panels.

    Science.gov (United States)

    El-Henawy, Sally I; Mohamed, Mohamed W N; Mashaly, Islam A; Mohamed, Osama N; Galal, Ola; Taha, Iman; Nassar, Khaled; Safwat, Amr M E

    2014-05-05

    With the high population growth rate, especially in developing countries, and the scarcity of land resources, buildings are becoming so close to each other, depriving the lower floors and the alleys from sunlight and consequently causing health problems. Therefore, there is an urgent need for cost-effective efficient light redirecting panels that guide sun rays into those dim places. In this paper, we address this problem. A novel sine wave based panel is presented to redirect/diverge light downward and enhance the illumination level in those dark places. Simulation results show that the proposed panel improves the illuminance values by more than 200% and 400% in autumn and winter respectively, operates over wide solar altitude ranges, and redirects light efficiently. Experimental and simulation results are in good agreement.

  5. Study on Optimization of Night Illumination in Expressway Long Tunnels

    Directory of Open Access Journals (Sweden)

    Weihua Zhao

    2012-01-01

    Full Text Available Night illumination of expressway long tunnels in China was far from drivers’ demand and caused lots of traffic accidents and electricity wasting. In order to solve this problem, reasonable night luminosity in expressway long tunnels in China was studied. Based on a visual disturbance generation mechanism, the mistakes in night illumination of Chinese expressway long tunnels were analyzed. Real road experiments were conducted and fuzzy assessments were used to establish models. The results showed that night luminosity was too high and should be controlled below 9 Lx. In the entrance segment, the luminosity should be gradually increased from 0 Lx to 9 Lx. In the middle segment, the luminosity should be remained at 9 Lx. In the exit segment, the luminosity should be gradually decreased to 0 Lx. The optimized luminosity is highly consistent with the actual demand of drivers. Traffic safety was improved and electricity consumption was reduced.

  6. Illuminating the Effects of Dynamic Lighting on Student Learning

    Directory of Open Access Journals (Sweden)

    Michael S. Mott

    2012-05-01

    Full Text Available Light is universally understood as essential to the human condition. Yet light quality varies substantially in nature and in controlled environments leading to questions of which artificial light characteristics facilitate maximum learning. Recent research has examined lighting variables of color temperature, and illumination for affecting sleep, mood, focus, motivation, concentration, and work and school performance. This has resulted in artificial light systems intended to support human beings in their actualization through dynamic lighting technology allowing for different lighting conditions per task. A total of 84 third graders were exposed to either focus (6000K-100fc average maintained or normal lighting. Focus lighting led to a higher percentage increase in oral reading fluency performance (36% than did control lighting (17%. No lighting effects were found for motivation or concentration, possibly attributable to the younger age level of respondents as compared with European studies. These findings illuminate the need for further research on artificial light and learning.

  7. 'No blue' LED solution for photolithography room illumination

    DEFF Research Database (Denmark)

    Ou, Haiyan; Corell, Dennis Dan; Dam-Hansen, Carsten

    2010-01-01

    This paper explored the feasibility of using a LED-based bulb as the illumination light source for photolithography room. A no-blue LED was designed, and the prototype was fabricated. The spectral power distribution of both the LED bulb and the yellow fluorescent tube was measured. Based on that......, colorimetric values were calculated and compared on terms of chromatic coordinates, correlated color temperature, color rendering index, and chromatic deviation. Gretagmacbeth color charts were used as a more visional way to compare the two light sources, which shows that our no-blue LED bulb has much better...... color rendering ability than the YFT. Furthermore, LED solution has design flexibility to improve it further. The prototype has been tested with photoresist SU8-2005. Even after 15 days of illumination, no effect was observed. So this LED-based solution was demonstrated to be a very promising light...

  8. Quasi-Bessel beams from asymmetric and astigmatic illumination sources.

    Science.gov (United States)

    Müller, Angelina; Wapler, Matthias C; Schwarz, Ulrich T; Reisacher, Markus; Holc, Katarzyna; Ambacher, Oliver; Wallrabe, Ulrike

    2016-07-25

    We study the spatial intensity distribution and the self-reconstruction of quasi-Bessel beams produced from refractive axicon lenses with edge emitting laser diodes as asymmetric and astigmatic illumination sources. Comparing these to a symmetric mono-mode fiber source, we find that the asymmetry results in a transition of a quasi-Bessel beam into a bow-tie shaped pattern and eventually to a line shaped profile at a larger distance along the optical axis. Furthermore, we analytically estimate and discuss the effects of astigmatism, substrate modes and non-perfect axicons. We find a good agreement between experiment, simulation and analytic considerations. Results include the derivation of a maximal axicon angle related to astigmatism of the illuminating beam, impact of laser diode beam profile imperfections like substrate modes and a longitudinal oscillation of the core intensity and radius caused by a rounded axicon tip.

  9. Structured illumination microscopy with unknown patterns and a statistical prior

    CERN Document Server

    Yeh, Li-Hao; Waller, Laura

    2016-01-01

    Structured illumination microscopy (SIM) improves resolution by down-modulating high-frequency information of an object to fit within the passband of the optical system. Generally, the reconstruction process requires prior knowledge of the illumination patterns, which implies a well-calibrated and aberration-free system. Here, we propose a new algorithmic self-calibration strategy for SIM that does not need to know the exact patterns a priori, but only their covariance. The algorithm, termed PE-SIMS, includes a Pattern-Estimation (PE) step and a SIM reconstruction procedure using a Statistical prior (SIMS). Additionally, we perform a pixel reassignment process (SIMS-PR) to enhance the reconstruction quality. We achieve 2x better resolution than a conventional widefield microscope, while remaining insensitive to aberration-induced pattern distortion and robust against parameter tuning compared to other blind SIM algorithms.

  10. Library-based illumination synthesis for critical CMOS patterning.

    Science.gov (United States)

    Yu, Jue-Chin; Yu, Peichen; Chao, Hsueh-Yung

    2013-07-01

    In optical microlithography, the illumination source for critical complementary metal-oxide-semiconductor layers needs to be determined in the early stage of a technology node with very limited design information, leading to simple binary shapes. Recently, the availability of freeform sources permits us to increase pattern fidelity and relax mask complexities with minimal insertion risks to the current manufacturing flow. However, source optimization across many patterns is often treated as a design-of-experiments problem, which may not fully exploit the benefits of a freeform source. In this paper, a rigorous source-optimization algorithm is presented via linear superposition of optimal sources for pre-selected patterns. We show that analytical solutions are made possible by using Hopkins formulation and quadratic programming. The algorithm allows synthesized illumination to be linked with assorted pattern libraries, which has a direct impact on design rule studies for early planning and design automation for full wafer optimization.

  11. Disk illumination by black hole superradiance of electromagnetic perturbations

    CERN Document Server

    Kobayashi, Taichi; Tomimatsu, Akira

    2008-01-01

    Using the Kerr-Schild formalism to solve the Einstein-Maxwell equations, we study energy transport due to time-dependent electromagnetic perturbations around a Kerr black hole, which may work as a mechanism to illuminate a disk located on the equatorial plane. For such a disk-hole system it is found that the energy extraction from the hole can occur under the well-known superradiance condition for wave frequency, even though the energy absorption into the hole should be rather dominant near the polar region of the horizon. We estimate the efficiency of the superradiant amplification of the disk illumination. Further we calculate the time-averaged energy density distribution to show explicitly the existence of a negative energy region near the horizon and to discuss the possible generation of a hot spot on the disk.

  12. Fully depleted back-illuminated p-channel CCD development

    Energy Technology Data Exchange (ETDEWEB)

    Bebek, Chris J.; Bercovitz, John H.; Groom, Donald E.; Holland, Stephen E.; Kadel, Richard W.; Karcher, Armin; Kolbe, William F.; Oluseyi, Hakeem M.; Palaio, Nicholas P.; Prasad, Val; Turko, Bojan T.; Wang, Guobin

    2003-07-08

    An overview of CCD development efforts at Lawrence Berkeley National Laboratory is presented. Operation of fully-depleted, back-illuminated CCD's fabricated on high resistivity silicon is described, along with results on the use of such CCD's at ground-based observatories. Radiation damage and point-spread function measurements are described, as well as discussion of CCD fabrication technologies.

  13. Understanding and Recreating Visual Appearance Under Natural Illumination

    Science.gov (United States)

    2011-01-01

    a time-lapse Eiffel Tower clip art object which, when inserted into a new scene, will automatically become correctly lit. 63 4.2 Overview Illuminant...skyscrapers from Tokyo are placed into an image sequence in Berkeley, CA (Fig. 4.5a); 2) the Eiffel Tower in Paris is composited into the Berlin skyline (Fig...building) (b) Object transfer ( Eiffel tower) (c) Sky transfer Figure 4.5: Appearance transfer between webcams. The first column shows example frames

  14. Infrared vertically-illuminated photodiode for chip alignment feedback

    CERN Document Server

    Alloatti, Luca

    2016-01-01

    We report on vertically-illuminated photodiodes fabricated in the GlobalFoundries 45nm 12SOI node and on a packaging concept for optically-interconnected chips. The photodiodes are responsive at 1180 nm, a wavelength currently used in chip-to-chip communications. They have further a wide field-of-view which enables chip-to-board positional feedback in chip-board assemblies. Monolithic integration enables on-chip processing of the positional data.

  15. Illuminating a dialectical transformative activist stance in education

    Science.gov (United States)

    Ritchie, Stephen M.

    2008-07-01

    In this essay I comment on Stetsenko's (2008) essay that draws together the work of Vygotsky, Piaget and Dewey, as she attempts to counter the `new' reductionist synthesis in public educational policy. While this theoretical work is helpful, it could be enhanced further by illuminating everyday practices of learners. I pose some questions that might provoke ongoing discussions by researchers as they transform collaboratively cultural-historical activity theory.

  16. Twin removal in digital holography using diffuse illumination

    OpenAIRE

    2009-01-01

    A method to numerically remove the twin image for inline digital holography, using multiple digital holograms, is discussed. Each individual hologram is recorded by using a statistically independent speckle field to illuminate the object. If the holograms are recorded in this manner and then numerically reconstructed, the twin image appears as a different speckle pattern in each of the reconstructions. By performing specklereduction techniques the presence of the twin image can be...

  17. Design tools for daylighting illumination and energy analysis

    Energy Technology Data Exchange (ETDEWEB)

    Selkowitz, S.

    1982-07-01

    The problems and potentials for using daylighting to provide illumination in building interiors are reviewed. It describes some of the design tools now or soon to be available for incorporating daylighting into the building design process. It also describes state-of-the-art methods for analyzing the impacts daylighting can have on selection of lighting controls, lighting energy consumption, heating and cooling loads, and peak power demand.

  18. Photo-induced changes of the optical constants of chalcodenide Ge19Sb1Te80 films

    Science.gov (United States)

    Pamukchieva, Vesela; Szekeres, Anna M.; Todorova, Kalina

    2004-10-01

    In this work a preliminary study of the influence of light illumination on the optical constants of chalcogenide thin films with non-stoichiometric Ge19Sb1Te80 composition is presented. Films of Ge19Sb1Te80 with a thickness of ~1 μm were deposited onto glass substrates by vacuum thermal evaporation of parent glasses. The as-deposited films were exposed to light by using a 500 W HBO mercury lamp. The optical constants of the films, before and after their illumination, were evaluated from the ellipsometric measurements in the spectral range of 300 - 820 nm. It has been established that illumination of the films leads to a decrease of the refractive index in the studied spectral region, while a slight increase of the extinction coefficient in the 600 - 800 nm range is observed. For the given film composition the optical bandgap energy of 0.76 eV reduces to 0.62 eV. The film structure shows a very slow recovery expresed in the increase of bandgap energy towards its initial value. The observed decrease of the bandgap energy after illumination is indicative that the film structure undergoes rearrangements upon exposure to light leading to the effect of photodarkening.

  19. The effect of illuminant position on perceived curvature.

    Science.gov (United States)

    Curran, W; Johnston, A

    1996-05-01

    In shaded scenes surface features can appear either concave or convex, depending upon the viewer's judgement about the direction of the prevailing illumination. If other curvature cues are added to the image this ambiguity can be removed. However, it is not clear to what extent, if any, illuminant position exerts an influence on the perceived magnitude of surface curvature. Subjects were presented with pairs of spherical surface patches in a curvature matching task. The patches were defined by shading and texture cues. The perceived curvature of a standard patch was measured as a function of light source position. We found a clear effect of light source position on apparent curvature. Perceived curvature decreased as light source tilt increased and as light source slant decreased. We also found that the strength of this effect is determined partly by a surface's reflectance function and partly by the relative weight of the texture cue. When a specular component was added to the stimuli, the effect of light source orientation was weakened. The weight of the texture cue was manipulated by disrupting the regular distribution of texture elements. We found an inverse relationship between the strength of the effect and the weight of the texture cue: lowering the texture cue weight resulted in an enhancement of the illuminant position effect.

  20. Image recombination transform algorithm for superresolution structured illumination microscopy

    Science.gov (United States)

    Zhou, Xing; Lei, Ming; Dan, Dan; Yao, Baoli; Yang, Yanlong; Qian, Jia; Chen, Guangde; Bianco, Piero R.

    2016-09-01

    Structured illumination microscopy (SIM) is an attractive choice for fast superresolution imaging. The generation of structured illumination patterns made by interference of laser beams is broadly employed to obtain high modulation depth of patterns, while the polarizations of the laser beams must be elaborately controlled to guarantee the high contrast of interference intensity, which brings a more complex configuration for the polarization control. The emerging pattern projection strategy is much more compact, but the modulation depth of patterns is deteriorated by the optical transfer function of the optical system, especially in high spatial frequency near the diffraction limit. Therefore, the traditional superresolution reconstruction algorithm for interference-based SIM will suffer from many artifacts in the case of projection-based SIM that possesses a low modulation depth. Here, we propose an alternative reconstruction algorithm based on image recombination transform, which provides an alternative solution to address this problem even in a weak modulation depth. We demonstrated the effectiveness of this algorithm in the multicolor superresolution imaging of bovine pulmonary arterial endothelial cells in our developed projection-based SIM system, which applies a computer controlled digital micromirror device for fast fringe generation and multicolor light-emitting diodes for illumination. The merit of the system incorporated with the proposed algorithm allows for a low excitation intensity fluorescence imaging even less than 1 W/cm2, which is beneficial for the long-term, in vivo superresolved imaging of live cells and tissues.

  1. The effect of retinal illuminance on visual motion priming.

    Science.gov (United States)

    Takeuchi, Tatsuto; Tuladhar, Anup; Yoshimoto, Sanae

    2011-05-25

    The perceived direction of a directionally ambiguous stimulus is influenced by the moving direction of a preceding priming stimulus. Previous studies have shown that a brief priming stimulus induces positive motion priming, in which a subsequent directionally ambiguous stimulus is perceived to move in the same direction as the primer, while a longer priming stimulus induces negative priming, in which the following ambiguous stimulus is perceived to move in the opposite direction of the primer. The purpose of this study was to elucidate the underlying mechanism of motion priming by examining how retinal illuminance and velocity of the primer influences the perception of priming. Subjects judged the perceived direction of 180-deg phase-shifted (thus directionally ambiguous) sine-wave gratings displayed immediately after the offset of a primer stimulus. We found that perception of motion priming was greatly modulated by the retinal illuminance and velocity of the primer. Under low retinal illuminance, positive priming nearly disappeared even when the effective luminance contrast was equated between different conditions. Positive priming was prominent when the velocity of the primer was low, while only negative priming was observed when the velocity was high. These results suggest that the positive motion priming is induced by a higher-order mechanism that tracks prominent features of the visual stimulus, while a directionally selective motion mechanism induces negative motion priming.

  2. Robust Crop and Weed Segmentation under Uncontrolled Outdoor Illumination

    Directory of Open Access Journals (Sweden)

    Hong Y. Jeon

    2011-06-01

    Full Text Available An image processing algorithm for detecting individual weeds was developed and evaluated. Weed detection processes included were normalized excessive green conversion, statistical threshold value estimation, adaptive image segmentation, median filter, morphological feature calculation and Artificial Neural Network (ANN. The developed algorithm was validated for its ability to identify and detect weeds and crop plants under uncontrolled outdoor illuminations. A machine vision implementing field robot captured field images under outdoor illuminations and the image processing algorithm automatically processed them without manual adjustment. The errors of the algorithm, when processing 666 field images, ranged from 2.1 to 2.9%. The ANN correctly detected 72.6% of crop plants from the identified plants, and considered the rest as weeds. However, the ANN identification rates for crop plants were improved up to 95.1% by addressing the error sources in the algorithm. The developed weed detection and image processing algorithm provides a novel method to identify plants against soil background under the uncontrolled outdoor illuminations, and to differentiate weeds from crop plants. Thus, the proposed new machine vision and processing algorithm may be useful for outdoor applications including plant specific direct applications (PSDA.

  3. Robust crop and weed segmentation under uncontrolled outdoor illumination.

    Science.gov (United States)

    Jeon, Hong Y; Tian, Lei F; Zhu, Heping

    2011-01-01

    An image processing algorithm for detecting individual weeds was developed and evaluated. Weed detection processes included were normalized excessive green conversion, statistical threshold value estimation, adaptive image segmentation, median filter, morphological feature calculation and Artificial Neural Network (ANN). The developed algorithm was validated for its ability to identify and detect weeds and crop plants under uncontrolled outdoor illuminations. A machine vision implementing field robot captured field images under outdoor illuminations and the image processing algorithm automatically processed them without manual adjustment. The errors of the algorithm, when processing 666 field images, ranged from 2.1 to 2.9%. The ANN correctly detected 72.6% of crop plants from the identified plants, and considered the rest as weeds. However, the ANN identification rates for crop plants were improved up to 95.1% by addressing the error sources in the algorithm. The developed weed detection and image processing algorithm provides a novel method to identify plants against soil background under the uncontrolled outdoor illuminations, and to differentiate weeds from crop plants. Thus, the proposed new machine vision and processing algorithm may be useful for outdoor applications including plant specific direct applications (PSDA).

  4. Illumination system design in a project-based course

    Science.gov (United States)

    Koshel, R. John; Abraham, Vineeth; Kim, Joshua; Liu, Ron; Richardson, Scott; Namnabat, Soha; Czajkowski, Amber; Abd El-Maksoud, Rania H.; Irvin, Ryan; Nakazawa, Takeshi; Kudenov, Michael; Dawsey, Martha; de Leon, Erich; Wang, Lirong; Crabtree, Karlton; Orr, R. M.; Primeau, Brian; Kim, Yullin

    2009-08-01

    This past spring a new for-credit course on illumination engineering was offered at the College of Optical Sciences at The University of Arizona. This course was project based such that the students could take a concept to conclusion. The main goal of the course was to learn how to use optical design and analysis software while applying principles of optics to the design of their optical systems. Projects included source modeling, displays, daylighting, light pollution, faceted reflectors, and stray light analysis. In conjunction with the course was a weekly lecture that provided information about various aspects of the field of illumination, including units, étendue, optimization, solid-state lighting, tolerancing, litappearance modeling, and fabrication of optics. These lectures harped on the important points of conservation of étendue, source modeling and tolerancing, and that no optic can be made perfectly. Based on student reviews, future versions of this course will include more hands-on demos of illumination components and assignments.

  5. Wavefront sensing in a partially illuminated, rotating pupil

    Science.gov (United States)

    Bertram, Thomas; Kumar Radhakrishnan Santhakumari, Kalyan; Marafatto, Luca; Arcidiacono, Carmelo; Berwein, Jürgen; Ragazzoni, Roberto; Herbst, Thomas M.

    2014-08-01

    LINC-NIRVANA is the near-infrared interferometric imaging camera for the Large Binocular Telescope. Once operational, it will provide an unprecedented combination of angular resolution, sensitivity, and field of view. Its pyramid-based layer-oriented MCAO systems are conjugated to the ground layer and to an additional layer in the upper atmosphere. The Groundlayer Wavefront Sensor optically coadds the light of up to 12 reference stars in the pupil, the Highlayer Wavefront Sensor optically combines the light of up to 8 reference stars in its metapupil. Each Wavefront Sensor has its own associated field derotator. It introduces a dependency of the sensor-actuator relation on the angle of the field derotator, which requires regular updates of the reconstructor in closed loop. In addition, the Highlayer Wavefront Sensor has to be able to reconstruct the incoming wavefronts by analyzing an only partially illuminated metapupil. The distribution of illuminated subapertures depends on the distribution of reference stars. For each pointing, a specific reconstruction matrix has to be generated, which only considers the illuminated subapertures. In this contribution we will present the concept of LINC-NIRVANA's wavefront reconstruction mechanism and report on laboratory and on-sky tests.

  6. Random laser illumination: an ideal source for biomedical polarization imaging?

    Science.gov (United States)

    Carvalho, Mariana T.; Lotay, Amrit S.; Kenny, Fiona M.; Girkin, John M.; Gomes, Anderson S. L.

    2016-03-01

    Imaging applications increasingly require light sources with high spectral density (power over spectral bandwidth. This has led in many cases to the replacement of conventional thermal light sources with bright light-emitting diodes (LEDs), lasers and superluminescent diodes. Although lasers and superluminescent diodes appear to be ideal light sources due to their narrow bandwidth and power, however, in the case of full-field imaging, their spatial coherence leads to coherent artefacts, such as speckle, that corrupt the image. LEDs, in contrast, have lower spatial coherence and thus seem the natural choice, but they have low spectral density. Random Lasers are an unconventional type of laser that can be engineered to provide low spatial coherence with high spectral density. These characteristics makes them potential sources for biological imaging applications where specific absorption and reflection are the characteristics required for state of the art imaging. In this work, a Random Laser (RL) is used to demonstrate speckle-free full-field imaging for polarization-dependent imaging in an epi-illumination configuration. We compare LED and RL illumination analysing the resulting images demonstrating that the RL illumination produces an imaging system with higher performance (image quality and spectral density) than that provided by LEDs.

  7. Detector Based Realisation of Illuminance Scale at NML-SIRIM

    Science.gov (United States)

    Abdullah, Mohd Nizam; Abidin, Mohd Nasir Zainal; Abidin, Abdul Rashid Zainal; Shaari, Sahbudin

    2009-07-01

    Illuminance scale is one of the fundamentals in the realisation of candela in optical radiation. The en route of the realisation is based on the fundamental process from the unbroken chain of traceability which includes from the primary standard disseminated to working standard and lastly the end user. There are many variations towards this realisation even though some of the national metrology institutes (NMI) does not have the primary standard but their traceability still valid. The realisation of National Metrology Laboratory SIRIM (NML-SIRIM), Malaysia illuminance scale is based on detector. The scale is traceable to National Physical Labortaory (NPL), United Kingdom (UK) by annually calibrating photometers and luminous intensity lamp. This paper describes measurement method and the system set-up was previously crosschecked with Korea Research Institute Standards and Science (KRISS), Republic of Korea. The agreement between both laboratories is within 0.5% the uncertainty maintained at NML-SIRIM. Furthermore, the basic measurement equation for illuminance realisation is also derived.

  8. PSM design for inverse lithography with partially coherent illumination.

    Science.gov (United States)

    Ma, Xu; Arce, Gonzalo R

    2008-11-24

    Phase-shifting masks (PSM) are resolution enhancement techniques (RET) used extensively in the semiconductor industry to improve the resolution and pattern fidelity of optical lithography. Recently, a set of gradient-based PSM optimization methods have been developed to solve for the inverse lithography problem under coherent illumination. Most practical lithography systems, however, use partially coherent illumination due to non-zero width and off-axis light sources, which introduce partial coherence factors that must be accounted for in the optimization of PSMs. This paper thus focuses on developing a framework for gradient-based PSM optimization methods which account for the inherent nonlinearities of partially coherent illumination. In particular, the singular value decomposition (SVD) is used to expand the partially coherent imaging equation by eigenfunctions into a sum of coherent systems (SOCS). The first order coherent approximation corresponding to the largest eigenvalue is used in the PSM optimization. In order to influence the solution patterns to have more desirable manufacturability properties and higher fidelity, a post-processing of the mask pattern based on the 2D discrete cosine transformation (DCT) is introduced. Furthermore, a photoresist tone reversing technique is exploited in the design of PSMs to project extremely sparse patterns.

  9. Koehler-illumination-based method to improve beam size controllability

    Science.gov (United States)

    Hattori, Kiyoshi; Sunaoshi, Hitoshi; Ando, Atsushi

    1998-06-01

    We have developed a new EB calibration method for adjusting both Koehler illumination condition and beam current density precisely in the EB direct writing system EX-8D. Koehler illumination condition is adjusted by controlling the condenser lens so that the beam size change on the target vs. focus change of the objective is minimized. Beam current density is adjusted to the desired value by controlling the two condenser lenses which acts as a zoom lens function and maintaining above Koehler illumination condition. Using this method, beam size deviation was improved to less than 2 nm for a focus change of 10 micrometers , and beam current density was controlled to less than 0.5 percent error from the desired value. This beam calibration was executed in less than 10 minutes. We have also evaluated the pattern roughness and the pattern size deviation depending on the focus change by delineating a 0.125 micrometers line and space pattern. The pattern roughness was controlled to less than 2 nm and the pattern size deviation was less than 2 nm for a focus change of +/- micrometers .

  10. 3D digitising using structured illumination: application to mould redesign

    Science.gov (United States)

    Granero, L.; Sánchez, J.; Micó, V.; Esteve, J. J.; Hervás, J.; Simón, S.; Pérez, E.

    2007-06-01

    Conventional techniques applied to three dimensional (3D) acquisition of information has significant limitations depending on the features of the piece under test. Thus, complex curvatures, deeper concavities and higher volumes are some examples of critical factors in which contact digitising systems are not suitable to undertake such kind of task. In these cases, the usage of optical 3D digitization systems implies a more appropriate way to obtain 3D information about the sample. In particular, structured illumination by means of white light provides point-to-point object acquisition with accuracy and resolution that are always below the manufactured tolerances. Moreover, when the object under test is too large, structured illumination can be mixed with photogrammetrical techniques in order to avoid errors by means of the delimitation of the overall working volume. This proceeding presents several real cases applied to mould industry in which 3D shape measurement using white light structured illumination is combined with finite element method (FEM) and laser cladding techniques to allow the repair of the mould.

  11. Process window study with various illuminations for EUV lithography applications

    Science.gov (United States)

    Lee, Sang Hun; Zhang, Zhiyu

    2007-03-01

    EUV lithography has the ability to support 22 nm logic manufacturing and beyond. Similar to the DUV lithographic systems, partial coherence on EUV lithographic systems can have a big impact on process latitude for critical layers. Thus, it is important to understand the effect of partial coherence on EUV imaging systems. In this paper, process windows with various illumination settings are investigated. The experiments are conducted using the MET station at the Advance Light Source (ALS). In addition to the annular and dipole illuminations which reported in our last paper1, C-quad and Quad illuminations are used to explore the impact of the partial coherence on the process window. Even though the MET system has resolutions below 30nm dense lines, the exposures are targeted for 60nm, 50nm, and 45nm dense features due to the resist limitation. The experimental results are compared with simulation results using Intel's lithography modeling tool, I-Photo. Resist and aerial image threshold models are used for the comparison study. The experimental results correlate well with the resist based simulation results, but some discrepancies are observed for the aerial image threshold cases. We believe the discrepancies are due to the resist limitations. We found that the dipole shows the largest Depth of Focus for dense lines and spaces.

  12. Non-Relativistic Spacetimes with Cosmological Constant

    OpenAIRE

    Aldrovandi, R.; Barbosa, A. L.; Crispino, L.C.B.; Pereira, J. G.

    1998-01-01

    Recent data on supernovae favor high values of the cosmological constant. Spacetimes with a cosmological constant have non-relativistic kinematics quite different from Galilean kinematics. De Sitter spacetimes, vacuum solutions of Einstein's equations with a cosmological constant, reduce in the non-relativistic limit to Newton-Hooke spacetimes, which are non-metric homogeneous spacetimes with non-vanishing curvature. The whole non-relativistic kinematics would then be modified, with possible ...

  13. Cosmological constant and Brane New World

    CERN Document Server

    Nojiri, S; Odintsov, S D; Nojiri, Shin'ichi; Obregon, Octavio; Odintsov, Sergei D.

    2001-01-01

    The estimation of the cosmological constant in inflationary Brane New World models is done. It is shown that basically it is quite large, of the same order as in anomaly-driven inflation. However, for some fine-tuning of bulk gravitational constant and AdS scale parameter $l^2$ it may be reduced to sufficiently small value. Bulk higher derivative AdS gravity with quantum brane matter may also serve as the model where small positive cosmological constant occurs.

  14. Singularities in universes with negative cosmological constant

    Energy Technology Data Exchange (ETDEWEB)

    Tipler, F.J.

    1976-10-01

    It is well known that many universes with negative cosmological constant contain singularities. We shall generalize this result by proving that all closed universes with negative cosmological constant are both future and past timelike geodesically incomplete if the strong energy condition holds. No global causality conditions or restrictions on the initial data are used in the proof. Furthermore, we shall show that all open universes with a Cauchy surface and a negative cosmological constant are singular if the strong energy condition holds. (AIP)

  15. Coasting cosmologies with time dependent cosmological constant

    CERN Document Server

    Pimentel, L O; Pimentel, Luis O.

    1999-01-01

    The effect of a time dependent cosmological constant is considered in a family of scalar tensor theories. Friedmann-Robertson-Walker cosmological models for vacumm and perfect fluid matter are found. They have a linear expansion factor, the so called coasting cosmology, the gravitational "constant" decreace inversely with time; this model satisfy the Dirac hipotesis. The cosmological "constant" decreace inversely with the square of time, therefore we can have a very small value for it at present time.

  16. On a time varying fine structure constant

    CERN Document Server

    Berman, M S; Berman, Marcelo S.; Trevisan, Luis A.

    2001-01-01

    By employing Dirac LNH, and a further generalization by Berman (GLNH), we estimate how should vary the total number of nucleons, the energy density, Newton Gravitational constant, the cosmological constant, the magnetic permeability and electric permitivity, of the Universe,in order to account for the experimentally observed time variation of the fine structure constant. As a bonus,we find an acceptable value for the deceleration parameter of the present Universe, compatible with the Supernovae observations.

  17. Equilibration kinetics in isolated and membrane-bound photosynthetic reaction centers upon illumination: a method to determine the photoexcitation rate.

    Science.gov (United States)

    Manzo, Anthony J; Goushcha, Alexander O; Barabash, Yuri M; Kharkyanen, Valery N; Scott, Gary W

    2009-07-01

    Kinetics of electron transfer, following variation of actinic light intensity, for photosynthetic reaction centers (RCs) of purple bacteria (isolated and membrane-bound) were analyzed by measuring absorbance changes in the primary photoelectron donor absorption band at 865 nm. The bleaching of the primary photoelectron donor absorption band in RCs, following a sudden increase of illumination from the dark to an actinic light intensity of I(exp), obeys a simple exponential law with the rate constant alphaI(exp) + k(rec), in which alpha is a parameter relating the light intensity, measured in mW/cm(2), to a corresponding theoretical rate in units of reciprocal seconds, and k(rec) is the effective rate constant of the charge recombination in the photosynthetic RCs. In this work, a method for determining the alpha parameter value is developed and experimentally verified for isolated and membrane-bound RCs, allowing for rigorous modeling of RC macromolecule dynamics under varied photoexcitation conditions. Such modeling is necessary for RCs due to alterations of the forward photoexcitation rates and relaxation rates caused by illumination history and intramolecular structural dynamics effects. It is demonstrated that the classical Bouguer-Lambert-Beer formalism can be applied for the samples with relatively low scattering, which is not necessarily the case with strongly scattering media or high light intensity excitation.

  18. 77 FR 57083 - American Illuminating Company, LLC; Supplemental Notice that Initial Market-Based Rate Filing...

    Science.gov (United States)

    2012-09-17

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Federal Energy Regulatory Commission American Illuminating Company, LLC; Supplemental Notice that Initial Market... in the above-referenced proceeding, of American Illuminating Company, LLC's application for...

  19. Flat-top illumination profile in an epifluorescence microscope by dual microlens arrays

    NARCIS (Netherlands)

    Coumans, F.A.W.; Pol, van der E.; Terstappen, L.W.M.M.

    2012-01-01

    Low uniformity in illumination across the image plane impairs the ability of a traditional epifluorescence microscope to quantify fluorescence intensities. Two microlens arrays (MLAs) were introduced into the illumination path of two different epifluorescence microscope systems to improve the unifor

  20. Solving the MCAO partial illumination issue and laboratory results

    Science.gov (United States)

    Santhakumari, K. K. R.; Arcidiacono, C.; Bertram, T.; Berwein, J.; Herbst, T. M.; Ragazzoni, R.

    2016-07-01

    Telescopes or instruments equipped with Multi-Conjugate Adaptive Optics (MCAO) provide uniform turbulence correction over a wide Field of View (FoV), thereby overcoming the problems of isoplanatism and enabling previously challenging science. LINC-NIRVANA (LN), the German-Italian near-infrared high-resolution imager for the Large Binocular Telescope (LBT), has an advanced and unique MCAO module, which uses the Optical Co-addition of Layer- Oriented Multiple-FoV Natural Guide Star approach to MCAO with pyramid wavefront sensing. The layer-oriented wavefront correction can be performed by conjugating the Deformable Mirrors (DM) and the respective Wavefront Sensors (WFS) to the corresponding atmospheric layers. LN corrects for the aberrations in two different layers. The ground layer, conjugated to the telescope pupil 100m above LBT, is corrected by the Ground-layer Wavefront Sensors (GWS) driving the LBT adaptive secondary mirrors, and a higher layer 7.1km above the telescope is corrected by the High-layer Wavefront Sensors (HWS) driving a pair of Xinetics DMs on the LN bench. At the ground layer, the footprints of the stars overlap completely and every star footprint illuminates the entire pupil-plane. However, for a higher layer, the footprints do not overlap completely and each star illuminates a different region of the conjugated plane. Lack of stars, therefore, results in some regions in this "meta-pupil"-plane not being illuminated, implying no information regarding the aberrations in these areas. The optimum way of correcting the high layer, given this limited information, is the crux of the "partial illumination issue". In this paper, we propose a solution for this issue and discuss laboratory results from the aligned LN bench in the lab. Currently, LN has completed the re-integration and re-alignment at LBT. In early June 2016, we tested our partial illumination algorithm in the instrument's final configuration in the LBT mountain lab, using simulated stars

  1. A natural cosmological constant from chameleons

    Directory of Open Access Journals (Sweden)

    Horatiu Nastase

    2015-07-01

    Full Text Available We present a simple model where the effective cosmological constant appears from chameleon scalar fields. For a Kachru–Kallosh–Linde–Trivedi (KKLT-inspired form of the potential and a particular chameleon coupling to the local density, patches of approximately constant scalar field potential cluster around regions of matter with density above a certain value, generating the effect of a cosmological constant on large scales. This construction addresses both the cosmological constant problem (why Λ is so small, yet nonzero and the coincidence problem (why Λ is comparable to the matter density now.

  2. Surprises in numerical expressions of physical constants

    CERN Document Server

    Amir, Ariel; Tokieda, Tadashi

    2016-01-01

    In science, as in life, `surprises' can be adequately appreciated only in the presence of a null model, what we expect a priori. In physics, theories sometimes express the values of dimensionless physical constants as combinations of mathematical constants like pi or e. The inverse problem also arises, whereby the measured value of a physical constant admits a `surprisingly' simple approximation in terms of well-known mathematical constants. Can we estimate the probability for this to be a mere coincidence, rather than an inkling of some theory? We answer the question in the most naive form.

  3. A natural cosmological constant from chameleons

    Energy Technology Data Exchange (ETDEWEB)

    Nastase, Horatiu, E-mail: nastase@ift.unesp.br [Instituto de Física Teórica, UNESP-Universidade Estadual Paulista, R. Dr. Bento T. Ferraz 271, Bl. II, Sao Paulo 01140-070, SP (Brazil); Weltman, Amanda, E-mail: amanda.weltman@uct.ac.za [Astrophysics, Cosmology & Gravity Center, Department of Mathematics and Applied Mathematics, University of Cape Town, Private Bag, Rondebosch 7700 (South Africa)

    2015-07-30

    We present a simple model where the effective cosmological constant appears from chameleon scalar fields. For a Kachru–Kallosh–Linde–Trivedi (KKLT)-inspired form of the potential and a particular chameleon coupling to the local density, patches of approximately constant scalar field potential cluster around regions of matter with density above a certain value, generating the effect of a cosmological constant on large scales. This construction addresses both the cosmological constant problem (why Λ is so small, yet nonzero) and the coincidence problem (why Λ is comparable to the matter density now)

  4. Studies in Illumination. 1. The Hygienic Conditions of Illumination in Certain Post Offices, Especially Relating to Visual Defects and Efficiency

    Science.gov (United States)

    1924-07-01

    Mazda lamps ------- 100 22. Curves giving spacing and size of lamps. Several rows of outlets-. 106 23. Curves giving spacing and -size of lamps. One...ACKNOWLEDGMENTS. In drawig,,g.up the general, plan of work, to the end that the survey might be made as complete as possible, the illuminating engineers of...the following engineers and representatives of these companies: Messrs. G. H., Stickney, A. L. Powell, J. H. Kur- lander, D. W. Atwater, F. W. Mathieu

  5. CRITICAL ILLUMINATION AND CRITICAL FREQUENCY FOR RESPONSE TO FLICKERED LIGHT, IN DRAGONFLY LARVAE

    Science.gov (United States)

    Crozier, W. J.; Wolf, Ernst; Zerrahn-Wolf, Gertrud

    1937-01-01

    Curves relating flicker frequency (F) to mean critical illumination (Im) for threshold response to flickered light, with equal durations of light and no light intervals, and relating illumination (I) to mean critical flicker frequency (Fm) for the same response, have been obtained from homogeneous data based upon the reactions of dragonfly larvae (Anax junius). These curves exhibit the properties already described in the case of the fish Lepomis. The curve for Fm lies above the curve of Im by an amount which, as a function of I, can be predicted from a knowledge either of the variation of Im or of Fm. The law of the observable connection between F and I is properly expressed as a band, not as a simple curve. The variation of Im (and of Fm) is not due to "experimental error," but is an expression of the variable character of the organism's capacity to exhibit the reaction which is the basis of the measurements. As in other series of measurements, P.E.I is a rectilinear function of Im; P.E.F passes through a maximum as F (or I) increases. The form of P.E.F as a function of I can be predicted from the measurements of P.E.I. It is pointed out that the equations which have been proposed for the interpretation of curves of critical flicker frequency as a function of intensity, based upon the balance of light adaptation and dark adaptation, have in fact the character of "population curves;" and that their contained constants do not have the properties requisite for the consistent application of the view that the shape of the F - I curve is governed by the steady state condition of adaptation. These curves can, however, be understood as resulting from the achievement of a certain level of difference between the average effect of a light flash and its average after effect during the dark interval. PMID:19872997

  6. Model-Based Illumination Correction for Face Images in Uncontrolled Scenarios

    NARCIS (Netherlands)

    Boom, Bas; Spreeuwers, Luuk; Veldhuis, Raymond

    2009-01-01

    Face Recognition under uncontrolled illumination conditions is partly an unsolved problem. Several illumination correction methods have been proposed, but these are usually tested on illumination conditions created in a laboratory. Our focus is more on uncontrolled conditions. We use the Phong model

  7. 41 CFR 102-74.180 - What illumination levels must Federal agencies maintain on Federal facilities?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What illumination levels... illumination levels must Federal agencies maintain on Federal facilities? Except where special circumstances exist, Federal agencies must maintain illumination levels at— (a) 50 foot-candles at work...

  8. Constant Width Planar Computation Characterizes ACC0

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Arnsfelt

    2006-01-01

    We obtain a characterization of ACC0 in terms of a natural class of constant width circuits, namely in terms of constant width polynomial size planar circuits. This is shown via a characterization of the class of acyclic digraphs which can be embedded on a cylinder surface in such a way that all...

  9. Constant Width Planar Computation Characterizes ACC0

    DEFF Research Database (Denmark)

    Hansen, K.A.

    2004-01-01

    We obtain a characterization of ACC 0 in terms of a natural class of constant width circuits, namely in terms of constant width polynomial size planar circuits. This is shown via a characterization of the class of acyclic digraphs which can be embedded on a cylinder surface in such a way that all...

  10. Chiral Corrections to Vector Meson Decay Constants

    CERN Document Server

    Bijnens, J; Talavera, P; Bijnens, Johan; Gosdzinsky, Peter; Talavera, Pere

    1998-01-01

    We calculate the leading quark mass corrections of order $m_q\\log(m_q)$, $m_q$ and $m_q^{3/2}$ to the vector meson decay constants within Heavy Vector Meson Chiral Perturbation Theory. We discuss the issue of electromagnetic gauge invariance and the heavy mass expansion. Reasonably good fits to the observed decay constants are obtained.

  11. Constant Angle Surfaces in the Heisenberg Group

    Institute of Scientific and Technical Information of China (English)

    Johan FASTENAKELS; Marian Ioan MUNTEANU; Joeri VAN DER VEKEN

    2011-01-01

    In this article we extend the notion of constant angle surfaces in S2 × R and H2 × R to general Bianchi-Cartan-Vranceanu spaces. We show that these surfaces have constant Gaussian curvature and we give a complete local classification in the Heisenberg group.

  12. The time constant of the somatogravic illusion.

    Science.gov (United States)

    Correia Grácio, B J; de Winkel, K N; Groen, E L; Wentink, M; Bos, J E

    2013-02-01

    Without visual feedback, humans perceive tilt when experiencing a sustained linear acceleration. This tilt illusion is commonly referred to as the somatogravic illusion. Although the physiological basis of the illusion seems to be well understood, the dynamic behavior is still subject to discussion. In this study, the dynamic behavior of the illusion was measured experimentally for three motion profiles with different frequency content. Subjects were exposed to pure centripetal accelerations in the lateral direction and were asked to indicate their tilt percept by means of a joystick. Variable-radius centrifugation during constant angular rotation was used to generate these motion profiles. Two self-motion perception models were fitted to the experimental data and were used to obtain the time constant of the somatogravic illusion. Results showed that the time constant of the somatogravic illusion was on the order of two seconds, in contrast to the higher time constant found in fixed-radius centrifugation studies. Furthermore, the time constant was significantly affected by the frequency content of the motion profiles. Motion profiles with higher frequency content revealed shorter time constants which cannot be explained by self-motion perception models that assume a fixed time constant. Therefore, these models need to be improved with a mechanism that deals with this variable time constant. Apart from the fundamental importance, these results also have practical consequences for the simulation of sustained accelerations in motion simulators.

  13. Physical Properties of Triglycerides IV. Dielectric Constant

    NARCIS (Netherlands)

    Gouw, T.H.; Vlugter, J.C.

    1967-01-01

    Dielectric constants at 20° and at 40° C of a number of triglycerides in the liquid state have been measured. A molar additive function of the dielectric constant, based on a relation derived by J. van Elk, was used in combination with a previously derived equation for triglycerides to give an equat

  14. Decay constants from twisted mass QCD

    CERN Document Server

    Dimopoulos, P; Michael, C; Simula, S; Urbach, C

    2008-01-01

    We present results for chiral extrapolations of the mass and decay constants of the rho meson. The data sets used are the nf=2 unquenched gauge configurations generated with twisted mass fermions by the European Twisted Mass Collaboration. We describe a calculation of three decay constants in charmonium and explain why they are required.

  15. Spacetime Dynamics from Spin Dynamics: Cosmological Constant and Neutrino Mass

    Science.gov (United States)

    Crawford, James

    2003-04-01

    Two fundamental unresolved issues in gravitational physics are the origin of the cosmological constant (dark energy), whose existence is suggested by the observed acceleration of the universe, and the origin of the particle masses, which we now know includes the neutrinos. Since all matter particles are represented by spinor fields, it seems natural to inquire whether the gravitational interaction of the spinor fields can illuminate these issues. Therefore we consider the possibility that the spin curvature is fundamental, and show that by relaxing the Schrödinger condition (covariant constancy of the Dirac matrices) it is possible to obtain both spacetime curvature and torsion as parts of the spin curvature. We assume a scale invariant Lagrangian composed of the standard Yang-Mills Lagrangian for the spin curvature and the massless Dirac Lagrangian for the spinors. An exact vacuum cosmological solution to the associated field equations is found which exhibits exponential acceleration of the universe and gives a minimum mass for all spinors.

  16. String theory, cosmology and varying constants

    Science.gov (United States)

    Damour, Thibault

    In string theory the coupling `constants' appearing in the low-energy effective Lagrangian are determined by the vacuum expectation values of some (a priori) massless scalar fields (dilaton, moduli). This naturally leads one to expect a correlated variation of all the coupling constants, and an associated violation of the equivalence principle. We review some string-inspired theoretical models which incorporate such a spacetime variation of coupling constants while remaining naturally compatible both with phenomenological constraints coming from geochemical data (Oklo; Rhenium decay) and with present equivalence principle tests. Barring a very unnatural fine-tuning of parameters, a variation of the fine-structure constant as large as that recently `observed' by Webb et al. in quasar absorption spectra appears to be incompatible with these phenomenological constraints. Independently of any model, it is emphasized that the best experimental probe of varying constants are high-precision tests of the universality of free fall, such as MICROSCOPE and STEP.

  17. String theory, cosmology and varying constants

    CERN Document Server

    Damour, Thibault Marie Alban Guillaume

    2002-01-01

    In string theory the coupling ``constants'' appearing in the low-energy effective Lagrangian are determined by the vacuum expectation values of some (a priori) massless scalar fields (dilaton, moduli). This naturally leads one to expect a correlated variation of all the coupling constants, and an associated violation of the equivalence principle. We review some string-inspired theoretical models which incorporate such a spacetime variation of coupling constants while remaining naturally compatible both with phenomenological constraints coming from geochemical data (Oklo; Rhenium decay) and with present equivalence principle tests. Barring a very unnatural fine-tuning of parameters, a variation of the fine-structure constant as large as that recently ``observed'' by Webb et al. in quasar absorption spectra appears to be incompatible with these phenomenological constraints. Independently of any model, it is emphasized that the best experimental probe of varying constants are high-precision tests of the universa...

  18. Cosmic Time Variation of the Gravitational Constant

    CERN Document Server

    Tomaschitz, R

    2000-01-01

    A pre-relativistic cosmological approach to electromagnetism and gravitation is explored that leads to a cosmic time variation of the fundamental constants. Space itself is supposed to have physical substance, which manifests by its permeability. The scale factors of the permeability tensor induce a time variation of the fundamental constants. Atomic radii, periods, and energy levels scale in cosmic time, which results in dispersionless redshifts without invoking a space expansion. Hubble constant and deceleration parameter are reviewed in this context. The time variation of the gravitational constant at the present epoch can be expressed in terms of these quantities. This provides a completely new way to restrain the deceleration parameter from laboratory bounds on the time variation of the gravitational constant. This variation also affects the redshift dependence of angular diameters and the surface brightness, and we study in some detail the redshift scaling of the linear sizes of radio sources. The effec...

  19. General Relativity, Cosmological Constant and Modular Forms

    CERN Document Server

    Kraniotis, G V

    2001-01-01

    Strong field (exact) solutions of the gravitational field equations of General Relativity in the presence of a Cosmological Constant are investigated. In particular, a full exact solution is derived within the inhomogeneous Szekeres-Szafron family of space-time line element with a nonzero Cosmological Constant. The resulting solution connects, in an intrinsic way, General Relativity with the theory of modular forms and elliptic curves and thus to the theory of Taniyama-Shimura.The homogeneous FLRW limit of the above space-time elements is recovered and we solve exactly the resulting Friedmann Robertson field equation with the appropriate matter density for generic values of the Cosmological Constant $ \\Lambda $ and curvature constant $K$. A formal expression for the Hubble constant is derived. The cosmological implications of the resulting non-linear solutions are systematically investigated. Two particularly interesting solutions i) the case of a flat universe $K=0,\\Lambda \

  20. Dark adaptation time for humans, after viewing a target illuminated with two different types of light sources

    CSIR Research Space (South Africa)

    Baumbach, J

    2011-07-01

    Full Text Available The differences in scotopic recovery time between LED illuminators and a tungsten-halogen illuminator was investigated. The spectral distribution and the luminous intensity distribution of all the supplied illuminators were measured. The scotopic...

  1. Unsupervised defect segmentation of patterned materials under NIR illumination

    Energy Technology Data Exchange (ETDEWEB)

    Millan, Maria S; Escofet, Jaume [Departament d' Optica y Optometria, Universitat Politecnica de Catalunya, Campus Terrassa. 08222 Terrassa, Barcelona (Spain); Rallo, Miquel, E-mail: millan@oo.upc.edu [Departament de Matematica Aplicada III, Universitat Politecnica de Catalunya, Campus Terrassa. 08222 Terrassa, Barcelona (Spain)

    2011-01-01

    An unsupervised detection method for automatic flaw segmentation in patterned materials (textile, non-woven, paper) that has no need of any defect-free references or a training stage is presented in this paper. Printed materials having a pattern of colored squares, bands, etc. superimposed to the background texture can be advantageously analyzed using NIR illumination and a camera with enough sensitivity to this region of the spectrum. The contrast reduction of the pattern in the NIR image facilitates material inspection and defect segmentation. Underdetection and misdetection errors can be reduced in comparison with the inspection performed under visible illumination. For woven fabrics, with periodic structure, the algorithm is based on the structural feature extraction of the weave repeat from the Fourier transform of the sample image. These features are used to define a set of multiresolution bandpass filters adapted to the fabric structure that operate in the Fourier domain. Inverse Fourier transformation, binarization and merging of the information obtained at different scales lead to the output image that contains flaws segmented from the fabric background. For non-woven and random textured materials, the algorithm combines the multiresolution Gabor analysis of the sample image with a statistical analysis of the wavelet coefficients corresponding to each detail. The information of all the channels is merged in a single binary output image where the defect appears segmented from the background. The method is applicable to random, non-periodic, and periodic textures. Since all the information to inspect a sample is obtained from the sample itself, the method is proof against heterogeneities between different samples of the material, in-plane positioning errors, scale variations and lack of homogeneous illumination. Experimental results are presented for a variety of materials and defects.

  2. Structured IR illumination for relative depth sensing in virtual interfaces

    Science.gov (United States)

    Kress, Bernard; Raulot, Victorien; Grossman, Michel

    2012-06-01

    Depth mapping or depth sensing has become a popular field, applied not only to automotive sensing for collision avoidance (radar) but also to gesture sensing for gaming and virtual interfaces (optical). Popular gesture sensing devices such as the Kinect from Microsoft's Xbox gaming device produce a full absolute depth map, which is in most cases not adapted to the task on hand (relative gesture sensing). We propose in this paper a new gesture sensing technique through structured IR illumination to provide a relative depth mapping rather than an absolute one, and this reducing the requirements on computing power and therefore enabling this technology for wearable computing such as see through display.

  3. Restoration of uneven illumination in light sheet microscopy images.

    Science.gov (United States)

    Uddin, Mohammad Shorif; Lee, Hwee Kuan; Preibisch, Stephan; Tomancak, Pavel

    2011-08-01

    Light microscopy images suffer from poor contrast due to light absorption and scattering by the media. The resulting decay in contrast varies exponentially across the image along the incident light path. Classical space invariant deconvolution approaches, while very effective in deblurring, are not designed for the restoration of uneven illumination in microscopy images. In this article, we present a modified radiative transfer theory approach to solve the contrast degradation problem of light sheet microscopy (LSM) images. We confirmed the effectiveness of our approach through simulation as well as real LSM images.

  4. Light induced modulation instability of surfaces under intense illumination

    KAUST Repository

    Burlakov, V. M.

    2013-12-17

    We show that a flat surface of a polymer in rubber state illuminated with intense electromagnetic radiation is unstable with respect to periodic modulation. Initial periodic perturbation is amplified due to periodic thermal expansion of the material heated by radiation. Periodic heating is due to focusing-defocusing effects caused by the initial surface modulation. The surface modulation has a period longer than the excitation wavelength and does not require coherent light source. Therefore, it is not related to the well-known laser induced periodic structures on polymer surfaces but may contribute to their formation and to other phenomena of light-matter interaction.

  5. Cultural Preferences to Color Quality of Illumination of Different Objects

    CERN Document Server

    Liu, Anqing; Žukauskas, Artūras; Vaicekauskas, Rimantas; Vitta, Prančiskas; Shur, Michael

    2013-01-01

    The preferences to color quality of illumination were investigated for American and Chinese subjects using a solid-state source of white light with the continuously tunable color saturation ability and correlated color temperature of quadrichromatic blends. Subjects were asked to identify both most natural and preferred blends. For very familiar objects, cultural differences did not affect the average of the selected blends. For less familiar objects (various paintings), cultural differences in the average selected blends depended on the level of the familiarity of the content. An unfamiliar painting also showed preferences to color temperature being dependent on the cultural background. In all cases, the American subjects exhibited noticeably wider distributions.

  6. Super-resolution photoacoustic fluctuation imaging with multiple speckle illumination

    CERN Document Server

    Chaigne, Thomas; Allain, Marc; Katz, Ori; Gigan, Sylvain; Sentenac, Anne; Bossy, Emmanuel

    2015-01-01

    In deep tissue photoacoustic imaging, the spatial resolution is inherently limited by acoustic diffraction. Moreover, as the ultrasound attenuation increases with frequency, resolution is often traded-off for penetration depth. Here we report on super-resolution photoacoustic imaging by use of multiple speckle illumination. Specifically, we show that the analysis of second-order fluctuations of the photoacoustic images combined with image deconvolution enables resolving optically absorbing structures beyond the acoustic diffraction limit. A resolution increase of almost a factor 2 is demonstrated experimentally. Our method introduces a new framework that could potentially lead to deep tissue photoacoustic imaging with sub-acoustic resolution.

  7. Analytic phase-factor equations for Talbot array illuminations.

    Science.gov (United States)

    Zhou, C; Stankovic, S; Tschudi, T

    1999-01-10

    Under specific circumstances the fractional Talbot effect can be described by simplified equations. We have obtained simplified analytic phase-factor equations to describe the relation between the pure-phase factors and their fractional Talbot distances behind a binary amplitude grating with an opening ratio of (1/M). We explain how these simple equations are obtained from the regularly rearranged neighboring phase differences. We point out that any intensity distribution with an irreducible opening ratio (M(N)/M) (M(N) illumination in this case. Experimental verification of our theoretical results is given.

  8. Redundant information from thermal illumination: quantum Darwinism in scattered photons

    Energy Technology Data Exchange (ETDEWEB)

    Jess Riedel, C; Zurek, Wojciech H, E-mail: criedel@physics.ucsb.edu [Theory Division, LANL, Los Alamos, NM 87545 (United States)

    2011-07-15

    We study quantum Darwinism, the redundant recording of information about the preferred states of a decohering system by its environment, for an object illuminated by a blackbody. We calculate the quantum mutual information between the object and its photon environment for blackbodies that cover an arbitrary section of the sky. In particular, we demonstrate that more extended sources have a reduced ability to create redundant information about the system, in agreement with previous evidence that initial mixedness of an environment slows-but does not stop-the production of records. We also show that the qualitative results are robust for more general initial states of the system.

  9. Improved sample injection and illumination for multicapillary systems.

    Science.gov (United States)

    Kahlaoui, Nidhal; Duval, Marie-Alix; Lefebvre, Françoise; Charon, Yves; Siebert, Rainer

    2008-01-01

    Multicapillary electrophoresis continues to see improvements in speed, robustness, and reliability. This paper reports on our work on two components belonging to a multicapillary sequencer developed in our group. Injection of the DNA samples into the capillaries was optimized to make it reproducible and to reduce the amount of sample volume required. An alternative laser illumination of the capillaries was also developed. Light intensity in the capillaries was increased as a result of a step-by-step scanning of the laser and the use of microlenses in front of the capillaries.

  10. Redundant information from thermal illumination: quantum Darwinism in scattered photons

    Science.gov (United States)

    Jess Riedel, C.; Zurek, Wojciech H.

    2011-07-01

    We study quantum Darwinism, the redundant recording of information about the preferred states of a decohering system by its environment, for an object illuminated by a blackbody. We calculate the quantum mutual information between the object and its photon environment for blackbodies that cover an arbitrary section of the sky. In particular, we demonstrate that more extended sources have a reduced ability to create redundant information about the system, in agreement with previous evidence that initial mixedness of an environment slows—but does not stop—the production of records. We also show that the qualitative results are robust for more general initial states of the system.

  11. Illumination, color and imaging evaluation and optimization of visual displays

    CERN Document Server

    Bodrogi , P

    2012-01-01

    This comprehensive and modern reference on display technology, Illumination, color and imaging focuses on visual effects and how displayed images are best matched to the human visual system. It teaches how to exploit the knowledge of color information processing to design usable, ergonomic, and visually pleasing displays and display environments. The contents describe design principles and methods to optimize self-luminous visual technologies for the user using modern still and motion image displays and the whole range of indoor light sources. Design principles and methods are derived from

  12. Augmented tracking and acquisition system for GBL satellite illumination

    Science.gov (United States)

    Brodsky, Aaron; Goodrich, Alan; Lawson, David G.; Holm, Richard W.

    1991-08-01

    The Augmented Tracking and Acquisition System (ATAS) provides the tracking acquisition aids, line-of-sight stabilization, and active closed-loop beam centering functions at two ground-based laser tracking sites for the Relay Mirror Experiment (RME). Simultaneous, steady illumination of the RME spacecraft with both ground beacons allows for successful beam relay between the two sites off of the orbiting mirror. Described in this paper is an overview of the functions, control system architectures, major subsystem components (steering mirrors and sensors), and mission operation of the ATAS subsystems. A brief discussion of ATAS evolution is included to show that versatility is needed for success.

  13. Subdiffraction scattered light imaging of gold nanoparticles using structured illumination.

    Science.gov (United States)

    Chang, Bo-Jui; Lin, Shiuan Huei; Chou, Li-Jun; Chiang, Su-Yu

    2011-12-15

    A reflective light-scattering (RLS) microscope with structured illumination (SI) provides subdiffraction resolution and improves the image quality of gold nanoparticles in biological systems. The three-dimensional (3D)-structured pattern is rapidly and precisely controlled with a spatial light modulator and scrambled at the conjugate image plane to increase spatial incoherence. The reconstructed SI-RLS image of 100 nm gold nanoparticles reveals lateral and axial resolutions of approximately 117 and 428 nm. We present a high-resolution image of gold nanoparticles inside a HeLa cell, with improved contrast.

  14. Twin removal in digital holography using diffuse illumination.

    Science.gov (United States)

    Monaghan, David S; Kelly, Damien P; Pandey, Nitesh; Hennelly, Bryan M

    2009-12-01

    A method to numerically remove the twin image for inline digital holography, using multiple digital holograms, is discussed. Each individual hologram is recorded by using a statistically independent speckle field to illuminate the object. If the holograms are recorded in this manner and then numerically reconstructed, the twin image appears as a different speckle pattern in each of the reconstructions. By performing speckle-reduction techniques the presence of the twin image can be greatly reduced. A theoretical model is developed, and experimental results are presented that validate this approach. We show experimentally that the dc object intensity term can also be removed by using this technique.

  15. GPU-Based Techniques for Global Illumination Effects

    CERN Document Server

    Szirmay-Kalos, László; Sbert, Mateu

    2008-01-01

    This book presents techniques to render photo-realistic images by programming the Graphics Processing Unit (GPU). We discuss effects such as mirror reflections, refractions, caustics, diffuse or glossy indirect illumination, radiosity, single or multiple scattering in participating media, tone reproduction, glow, and depth of field. This book targets game developers, graphics programmers, and also students with some basic understanding of computer graphics algorithms, rendering APIs like Direct3D or OpenGL, and shader programming. In order to make this book self-contained, the most important c

  16. Effects of varying the percentage of key illuminations paired with food in a positive automaintenance procedure.

    Science.gov (United States)

    Gonzalez, F A

    1974-11-01

    Three pigeons were exposed to a positive automaintenance procedure in which each trial began with a brief tone followed by the transillumination of a small central area of the response key for 10 sec. Key illumination was followed by food on 100%, 50%, 25%, 12.5%, and 0% of the trials. The effects depended on the dependent variable observed. The mean rate of responding during key illumination rapidly increased and then decreased slightly as the percentage of key illuminations paired with food increased. The number of key illuminations during which at least one response occurred increased as a negatively accelerating function of the percentage of key illuminations paired with food, and the mean latency to the first response during the key illuminations decreased as a negatively decelerating function of the percentage condition. The mean rate of sustained responding during key illumination was not systematically affected by changes in the percentage conditions.

  17. Performance of Series Connected GaAs Photovoltaic Converters under Multimode Optical Fiber Illumination

    Directory of Open Access Journals (Sweden)

    Tiqiang Shan

    2014-01-01

    Full Text Available In many military and industrial applications, GaAs photovoltaic (PV converters are connected in series in order to generate the required voltage compatible with most common electronics. Multimode optical fibers are usually used to carry high-intensity laser and illuminate the series connected GaAs PV converters in real time. However, multimode optical fiber illumination has a speckled intensity pattern. The series connected PV array is extremely sensitive to nonuniform illumination; its performance is limited severely by the converter that is illuminated the least. This paper quantifies the effects of multimode optical fiber illumination on the performance of series connected GaAs PV converters, analyzes the loss mechanisms due to speckles, and discusses the maximum illumination efficiency. In order to describe the illumination dependent behavior detailedly, modeling of the series connected PV array is accomplished based on the equivalent circuit for PV cells. Finally, a series of experiments are carried out to demonstrate the theory analysis.

  18. Verification of simple illuminance based measures for indication of discomfort glare from windows

    DEFF Research Database (Denmark)

    Karlsen, Line Røseth; Heiselberg, Per Kvols; Bryn, Ida

    2015-01-01

    predictions of discomfort glare from windows already in the early design stage when decisions regarding the façade are taken. This study focus on verifying if simple illuminance based measures like vertical illuminance at eye level or horizontal illuminance at the desk are correlated with the perceived glare...... confirm that there is a statistically significant correlation between both vertical eye illuminance and horizontal illuminance at the desk and the occupants’ perception of glare in a perimeter zone office environment, which is promising evidence towards utilizing such simple measures for indication...... of discomfort glare in early building design. Further, the observed response indicate that the participants in the present study were more tolerant to low illuminance levels and more sensitive to high illuminance levels than the DGPs model would predict. More and larger studies are needed to confirm or enfeeble...

  19. Some Zero-Sum Constants with Weights

    Indian Academy of Sciences (India)

    S D Adhikari; R Balasubramanian; F Pappalardi; P Rath

    2008-05-01

    For an abelian group , the Davenport constant () is defined to be the smallest natural number such that any sequence of elements in has a non-empty subsequence whose sum is zero (the identity element). Motivated by some recent developments around the notion of Davenport constant with weights, we study them in some basic cases. We also define a new combinatorial invariant related to $(\\mathbb{Z}/n\\mathbb{Z})^d$, more in the spirit of some constants considered by Harborth and others and obtain its exact value in the case of $(\\mathbb{Z}/n\\mathbb{Z})^2$ where is an odd integer.

  20. EFFECTS OF CONSTANT EXCITATION ON LOCAL BIFURCATION

    Institute of Scientific and Technical Information of China (English)

    WU Zhi-qiang; CHEN Yu-shu

    2006-01-01

    The effects of the constant excitation on the local bifurcation of the periodic solutions in the 1:2 internal resonant systems were analyzed based on the singularity theory. It is shown that the constant excitation make influence only when there exist some nonlinear terms, in the oscillator with lower frequency. Besides acting as main bifurcation parameter, the constant excitation, together with coefficients of some nonlinear terms,may change the values of unfolding parameters and the type of the bifurcation. Under the non-degenerate cases, the effect of the third order terms can be neglected.

  1. On the constants for some Sobolev imbeddings

    Directory of Open Access Journals (Sweden)

    Pizzocchero Livio

    2001-01-01

    Full Text Available We consider the imbedding inequality is the Sobolev space (or Bessel potential space of type and (integer or fractional order . We write down upper bounds for the constants , using an argument previously applied in the literature in particular cases. We prove that the upper bounds computed in this way are in fact the sharp constants if , , and exhibit the maximising functions. Furthermore, using convenient trial functions, we derive lower bounds on for in many cases these are close to the previous upper bounds, as illustrated by a number of examples, thus characterizing the sharp constants with little uncertainty.

  2. The Determination of the Strong Coupling Constant

    Science.gov (United States)

    Dissertori, Günther

    2016-10-01

    The strong coupling constant is one of the fundamental parameters of the Standard Theory of particle physics. In this review I will briefly summarise the theoretical framework, within which the strong coupling constant is defined and how it is connected to measurable observables. Then I will give an historical overview of its experimental determinations and discuss the current status and world average value. Among the many different techniques used to determine this coupling constant in the context of quantum chromodynamics, I will focus in particular on a number of measurements carried out at the Large Electron-Positron Collider (LEP) and the Large Hadron Collider (LHC) at CERN.

  3. Marshak waves: Constant flux vs constant T-a (slight) paradigm shift

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, M.D.

    1994-12-22

    We review the basic scaling laws for Marshak waves and point out the differences in results for wall loss, albedo, and Marshak depth when a constant absorbed flux is considered as opposed to a constant absorbed temperature. Comparisons with LASNEX simulations and with data are presented that imply that a constant absorbed flux is a more appropriate boundary condition.

  4. Influence of illumination on autonomic thermoregulation and choice of clothing

    Science.gov (United States)

    Kim, Seung Hi; Jeong, Woon Seon

    2002-04-01

    This study was conducted to investigate how different levels of illumination below 1,000 lx would affect the autonomic and behavioral temperature regulation of humans. Seven healthy college-aged women (20+/-0 years) volunteered to participate in this study. They were exposed to a temperature of 26 °C in 320 lx for 30 min ('Equilibrium') followed by 700 lx or 70 lx for 30 min (stage 1). After stage 1, they were exposed to 20 °C for 30 min in the same illumination as in stage 1 (stage 2). In stage 2 the subjects were instructed to select and wear the clothing they needed for their thermal comfort. The data obtained were analyzed by paired t-test and repeated measures of analysis of variance. Forearm skin blood flow tended to remain steady in 700 lx but decreased markedly in 70 lx in stage 1. There were no significant differences between subjective thermal responses of the subjects experiencing 700 lx or 70 lx in both stages although the subjects felt cooler in stage 2 than in stage 1. The subjects were likely to prefer wearing heavier clothing in 70 lx than in 700 lx. It was concluded that vasoconstriction in the upper limbs occurred more strongly in dim light, which might result in different clothing preferences in a cool environment from those associated with brighter light intensity.

  5. Vertically illuminated TW-UTC photodiodes for terahertz generation

    Science.gov (United States)

    Barrientos Z., Claudio M.; Calle G., Victor H.; Alvarez, Jaime A.; Mena, F. Patricio; Vukusic, Josip; Stake, Jan; Michael, Ernest A.

    2012-09-01

    More efficient and powerful continuous-wave photonic mixers as terahertz sources are motivated by the need of more versatile local oscillators for submillimeter/terahertz receiver systems. Uni-Travelling Carrier (UTC) photodiodes are very prospective candidates for reaching this objective, but so far only have been reported as lumped-elements or as edge-illuminated optical-waveguide travelling-wave (TW) devices. To overcome the associated power limitations of those implementations, we are developing a novel implementation of the UTC photodiodes which combines a travelingwave photomixer with vertical velocity-matched illumination in a distributed structure. In this implementation called velocity-matched travelling-wave uni-travelling carrier photodiode, it is possible to obtain in-situ velocity matching of the beat-fringes of the two angled laser beams with the submm/THz-wave on the stripline. In this way, minimum frequency roll-off is achieved by tuning the angle between the two laser beams. A first design of these TW-UTC PDs from our Terahertz Photonics Laboratory at University of Chile has been micro-fabricated at the MC2 cleanroom facility at Chalmers Technical University.

  6. Three-dimensional illumination system for tomographic particle image velocimetry

    Science.gov (United States)

    Zhang, Fen; Song, Yang; Qu, Xiangju; Ji, Yunjing; Li, Zhenhua; He, Anzhi

    2016-10-01

    Tomographic particle image velocimetry (Tomo-PIV) is a new developed technique for three-component threedimensional (3C-3D) velocity measurement of the flow field based on the optical tomographic reconstruction method, and has been received extensive attention of the related industries. Three-dimensional light source illuminating the tracer particles of flow field is a critical application for tomographic particle image velocimetry. Three-dimensional light source not only determines the size of measurement volume and the range of the scope of application, but also has a great influence on the image quality. In this work, we propose a rectangular light amplification system using powell lens, prisms and two reflectors. The system can be optimized if given the system parameters based on the theoretical model. The rectangular light amplification system will be verified experimentally by measuring the cross section size of the illuminated light source. A 60mm×25mm cross section of rectangular three-dimensional light source can be obtained by using the rectangular light amplification system. The experiments demonstrate the the feasibility the proposed system.

  7. Image quality of a mobile display under different illuminations.

    Science.gov (United States)

    Lin, Po-Hung; Kuo, Wen-Hung

    2011-08-01

    This study constructed the image quality models for a small mobile display under different ambient illumination levels using Group Method and Data Handling (GMDH) and described the relationship between perceived image quality and physical measurements. 33 college students took part in this experiment and were asked to evaluate the image quality under 1500 lux (typical indoor office illumination) and 7000 lux (simulated outdoor environment) in Stage One and Stage Two, respectively. In each stage, the participants had to evaluate 21 images. 17 sets of the data as a training set were used to build the model and four sets of the data as a testing set were used to verify the model. The results indicated that the effects of luminance, contrast, correlated color temperature (CCT), and resolution were significant on perceived image quality under 1500 lux. However, color temperature was not a significant physical characteristic, and an interaction between luminance and contrast was found below 7000 lux. From the results of the experiment, it is considered that the outdoor environment (7000 lux) is not suitable for using mobile displays. Finally, once a valid image quality model is built, the subjective image quality can be established when the measurements of significant physical characteristics are provided. The results of subjective ratings can also be provided for mobile display manufacturers to improve the product quality so that their products can meet customers' requirements.

  8. Pulmonary decontamination for photodynamic inactivation with extracorporeal illumination

    Science.gov (United States)

    Geralde, Mariana C.; Leite, Ilaiáli S.; Inada, Natalia M.; Grecco, Clóvis; Medeiros, Alexandra I.; Kurachi, Cristina; Bagnato, Vanderlei S.

    2014-03-01

    Infectious pneumonia is a major cause of morbidity and mortality, despite advances in diagnostics and therapeutics in pulmonary infections. One of the major difficulties associated with the infection comes from the high rate of antibiotic resistant microorganisms, claiming for the use of alternative techniques with high efficiency and low cost. The photodynamic inactivation (PDI) is emerging as one of the great possibilities in this area, once its action is oxidative, not allowing microorganism develops resistance against the treatment. PDI for decontamination pulmonary has potential for treatment or creating better conditions for the action of antibiotics. In this study, we are developing a device to implement PDI for the treatment of lung diseases with extracorporeal illumination. To validate our theory, we performed measurements in liquid phantom to simulate light penetration in biological tissues at various fluency rates, the temperature was monitored in a body of hairless mice and the measurements of light transmittance in this same animal model. A diode laser emitting at 810 nm in continuous mode was used. Our results show 70% of leakage at 0.5 mm of thickness in phantom model. The mouse body temperature variation was 5.4 °C and was observed light transmittance through its chest. These results are suggesting the possible application of the extracorporeal illumination using infrared light source. Based on these findings, further studies about photodynamic inactivation will be performed in animal model using indocyanine green and bacteriochlorin as photosensitizers. The pulmonary infection will be induced with Streptococcus pneumoniae and Klebsiella pneumoniae.

  9. QR code optical encryption using spatially incoherent illumination

    Science.gov (United States)

    Cheremkhin, P. A.; Krasnov, V. V.; Rodin, V. G.; Starikov, R. S.

    2017-02-01

    Optical encryption is an actively developing field of science. The majority of encryption techniques use coherent illumination and suffer from speckle noise, which severely limits their applicability. The spatially incoherent encryption technique does not have this drawback, but its effectiveness is dependent on the Fourier spectrum properties of the image to be encrypted. The application of a quick response (QR) code in the capacity of a data container solves this problem, and the embedded error correction code also enables errorless decryption. The optical encryption of digital information in the form of QR codes using spatially incoherent illumination was implemented experimentally. The encryption is based on the optical convolution of the image to be encrypted with the kinoform point spread function, which serves as an encryption key. Two liquid crystal spatial light modulators were used in the experimental setup for the QR code and the kinoform imaging, respectively. The quality of the encryption and decryption was analyzed in relation to the QR code size. Decryption was conducted digitally. The successful decryption of encrypted QR codes of up to 129  ×  129 pixels was demonstrated. A comparison with the coherent QR code encryption technique showed that the proposed technique has a signal-to-noise ratio that is at least two times higher.

  10. Fast structured illumination microscopy using rolling shutter cameras

    Science.gov (United States)

    Song, Liyan; Lu-Walther, Hui-Wen; Förster, Ronny; Jost, Aurélie; Kielhorn, Martin; Zhou, Jianying; Heintzmann, Rainer

    2016-05-01

    Spatial light modulators (SLM) update in a synchronous manner, whereas the data readout process in fast structured illumination systems is usually done using a rolling shutter camera with asynchronous readout. In structured illumination microscopy (SIM), this leads to synchronization problems causing a speed limit for fast acquisition. In this paper we present a configuration to overcome this limit by exploiting the extremely fast SLM display and dividing it into several segments along the direction of the rolling shutter of the sCMOS camera and displaying multiple SLM frames per camera acquisition. The sCMOS runs in continuous rolling shutter mode and the SLM keeps the readout-line always inside a dark region presenting different SIM patterns before and after the readout/start-exposure line. Using this approach, we reached a raw frame rate of 714 frames per second (fps) resulting in a two-beam SIM acquisition rate of 79 fps with a region of interest (ROI) of 16.5  ×  16.5 μm2.

  11. Photochromic film texturing with speckle illumination: application to goods authentication

    Science.gov (United States)

    Crespo-Monteiro, Nicolas; Destouches, Nathalie; Fournel, Thierry

    2012-10-01

    Thanks to the localized surface plasmon resonance of silver nanoparticles, mesoporous titania films loaded with silver salts manifest a photochromic behavior that can be used to perform updatable laser microinscriptions. Under UV illumination, the silver salts are reduced into silver nanoparticles and the illuminated areas become grey-brown. This coloration can be completely erased by oxidizing the silver nanoparticles with a polychromatic or monochromatic visible light whose spectrum lies in the resonance band of silver nanoparticles. The paper investigates the usage of such photochromic Ag/TiO2 films for creating an updatable random texturing. Random textures are produced on coated glass samples, initially homogeneous, by exposing them to speckle patterns resulting from the scattering of a UV laser beam from an optically rough surface. The stability of such textures under homogeneous UV post-exposures is investigated as a function of the speckle exposure time. Under optimized exposure conditions, the textures remain stable enough for a long time and the differences between textures are sufficiently discriminative to use the texturing process for goods authentication. This is demonstrated by calculating the correlation coefficient of thousands of couples of texture images. The numerical treatment of images has the advantage to be robust to changes in the sample repositioning between different image records. The rewritability of the samples is characterized through the comparison of different textures successively erased and written at the same place on multiple samples.

  12. A versatile sample holder for single plane illumination microscopy.

    Science.gov (United States)

    Desmaison, Annaïck; Lorenzo, Corinne; Rouquette, Jacques; Ducommun, Bernard; Lobjois, Valérie

    2013-08-01

    Single Plane Illumination Microscopy is an emerging and powerful technology for live imaging of whole living organisms. However, sample handling that relies on specimen embedding in agarose or gel is often a key limitation, especially for time-lapse monitoring. To address this issue, we developed a new concept for a holder device allowing us to prepare a sample container made of hydrogel. The production process of this holder is based on 3D printing of both a frame and casting devices. The simplicity of production and the advantages of this versatile new sample holder are shown with time-lapse recording of multicellular tumour spheroid growth. More importantly, we also show that cell division is not impaired in contrast to what is observed with gel embedding. The benefit of this new holder for other sample types, applications and experiments remains to be evaluated, but this innovative concept of fully customizable sample holder preparation potentially represents a major step forward to facilitate the large diffusion of single plane illumination microscopy technology.

  13. Spatially multiplexed interferometric microscopy with partially coherent illumination

    Science.gov (United States)

    Picazo-Bueno, José Ángel; Zalevsky, Zeev; García, Javier; Ferreira, Carlos; Micó, Vicente

    2016-10-01

    We have recently reported on a simple, low cost, and highly stable way to convert a standard microscope into a holographic one [Opt. Express 22, 14929 (2014)]. The method, named spatially multiplexed interferometric microscopy (SMIM), proposes an off-axis holographic architecture implemented onto a regular (nonholographic) microscope with minimum modifications: the use of coherent illumination and a properly placed and selected one-dimensional diffraction grating. In this contribution, we report on the implementation of partially (temporally reduced) coherent illumination in SMIM as a way to improve quantitative phase imaging. The use of low coherence sources forces the application of phase shifting algorithm instead of off-axis holographic recording to recover the sample's phase information but improves phase reconstruction due to coherence noise reduction. In addition, a less restrictive field of view limitation (1/2) is implemented in comparison with our previously reported scheme (1/3). The proposed modification is experimentally validated in a regular Olympus BX-60 upright microscope considering a wide range of samples (resolution test, microbeads, swine sperm cells, red blood cells, and prostate cancer cells).

  14. Efficient cultural heritage image restoration with nonuniform illumination enhancement

    Science.gov (United States)

    Jmal, Marwa; Souidene, Wided; Attia, Rabah

    2017-01-01

    Cultural heritage digitization has been of research interest for several decades. For such, the quality of the stored images should be pleasant to see. However, as images captured by digital devices may include undesirable effects, conducting an enhancement on the image is essential. In this context, we present a framework for the purpose of cultural heritage image illumination enhancement. First, a mapping curve based on saturation feedback is created to adjust the contrast. Then illumination is enhanced by applying a modified homomorphic filter in the frequency domain. The technique employs an optimization search process based on the efficient golden section search algorithm to compute the optimal parameters to produce the enhanced image. Finally, a color restoration function is applied to overcome the problem of color violation. The resulted image represents a trade-off among local contrast improvement, detail enhancement, and preserving the naturalness of the image. Experiments are conducted on a collected dataset of cultural heritage images and compared to some of the state-of-the-art image enhancement methods using a set of quantitative assessments criteria. Results have shown that our proposed approach is able to accomplish a wide set of the performance goals.

  15. Assessment of electrical burn injury using structured illumination in an in-vivo electrical injury model

    Science.gov (United States)

    Nguyen, Thu T. A.; Basiri, Ali; Shupp, J. W.; Moffatt, L. T.; Jordan, M. H.; Jeng, J. C.; Leto, E.; Ramella-Roman, J. C.

    2011-03-01

    Electrical injury is a devastating and hard to treat clinical lesion. Fully understanding the pathophysiology of electrical trauma is still a challenge for clinicians and scientists. Further elucidating the natural history of this form of tissue injury could be helpful in improving limb salvage and offering stage-appropriate therapy. Multi-spectral imaging technique is a non-invasive technology that can be used to determine optical properties of tissues in and adjacent to injury. Images at different wavelengths can provide essential information related to the pathophysiological condition of the tissue. To promote the applicability of this technique in medical diagnosis, we built a complete experimental model of electrical injury. In this model, electrical injuries were created by a reliable high-tension shock system at preset voltage or current. A thermal camera recorded the change of skin temperature during the electrical shock. Then, a high-resolution spectral imaging system based on structured illumination was used to capture images for post analysis to extrapolate optical properties of the tissue. To test accuracy, this imaging system was calibrated by using a set of epoxy phantoms with known optical properties. In this paper, the results of experiments conducted on rats and discussions on the systemic changes in tissue optical properties before and after electrical shock are presented.

  16. The time constant of the somatogravic illusion

    NARCIS (Netherlands)

    Correia Grácio, B.J.; Winkel, K.N. de; Groen, E.L.; Wentink, M.; Bos, J.E.

    2013-01-01

    Met desdemona hebben we gevonden dat de tijd constante van de somatografische illusie rond twee seconden is. Dit resultaat verschilt van wat was gevonden in ander onderzoek dat gebruikt maakt van een gewone centrifuge

  17. Black holes with constant topological Euler density

    CERN Document Server

    Bargueño, Pedro

    2016-01-01

    A class of four dimensional spherically symmetric and static geometries with constant topological Euler density is studied. These geometries are shown to solve the coupled Einstein-Maxwell system when non-linear Born-Infeld-like electrodynamics is employed.

  18. STABILITY CONSTANT OF THE TRISGLYCINATO METAL ...

    African Journals Online (AJOL)

    DR. AMINU

    Department of Pure and Industrial Chemistry,Bayero University Kano, P. M. B. 3011, Kano, ... The stability constants of iron, manganese, cobalt, and nickel complexes of glycine have been ... bidentate ligand in its coordination with metal ions.

  19. Interacting universes and the cosmological constant

    Energy Technology Data Exchange (ETDEWEB)

    Alonso-Serrano, A. [Centro de Física “Miguel Catalán”, Instituto de Física Fundamental, Consejo Superior de Investigaciones Científicas, Serrano 121, 28006 Madrid (Spain); Estación Ecológica de Biocosmología, Pedro de Alvarado 14, 06411 Medellín (Spain); Bastos, C. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Avenida Rovisco Pais 1, 1049-001 Lisboa (Portugal); Bertolami, O. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Avenida Rovisco Pais 1, 1049-001 Lisboa (Portugal); Departamento de Física e Astronomia, Faculdade de Ciências da Universidade do Porto, Rua do Campo Alegre 687, 4169-007 Porto (Portugal); Robles-Pérez, S., E-mail: salvarp@imaff.cfmac.csic.es [Centro de Física “Miguel Catalán”, Instituto de Física Fundamental, Consejo Superior de Investigaciones Científicas, Serrano 121, 28006 Madrid (Spain); Estación Ecológica de Biocosmología, Pedro de Alvarado 14, 06411 Medellín (Spain); Física Teórica, Universidad del País Vasco, Apartado 644, 48080 Bilbao (Spain)

    2013-02-12

    In this Letter it is studied the effects that an interaction scheme among universes can have in the values of their cosmological constants. In the case of two interacting universes, the value of the cosmological constant of one of the universes becomes very close to zero at the expense of an increasing value of the cosmological constant of the partner universe. In the more general case of a chain of N interacting universes with periodic boundary conditions, the spectrum of the Hamiltonian splits into a large number of levels, each of them associated with a particular value of the cosmological constant, that can be occupied by single universes revealing a collective behavior that plainly shows that the multiverse is much more than the mere sum of its parts.

  20. Determination of the gravitational constant G

    Institute of Scientific and Technical Information of China (English)

    HU Zhong-kun; LIU Qi; LUO Jun

    2006-01-01

    A precise knowledge of the Newtonian gravitational constant G has an important role in physics and is of considerable meteorological interest.Although G was the first physical constant to be introduced and measured in the history of science,it is still the least precisely determined of all the fundamental constants of nature.The 2002 CODATA recommended value for G,G=(6.6742±0.0010)×10-11m3·kg-1·s-2,has an uncertainty of 150 parts per million (ppm),much larger than that of all other fundamental constants.Reviewed here is the status of our knowledge of the absolute value of G,methods for determining G,and recent high precision experiments for determining G.

  1. Prime rings with PI rings of constants

    CERN Document Server

    Kharchenko, V K; Rodríguez-Romo, S

    1996-01-01

    It is shown that if the ring of constants of a restricted differential Lie algebra with a quasi-Frobenius inner part satisfies a polynomial identity (PI) then the original prime ring has a generalized polynomial identitiy (GPI). If additionally the ring of constants is semiprime then the original ring is PI. The case of a non-quasi-Frobenius inner part is also considered.

  2. Trialogue on the number of fundamental constants

    CERN Document Server

    Duff, Michael J; Veneziano, Gabriele

    2002-01-01

    This paper consists of three separate articles on the number of fundamental dimensionful constants in physics. We started our debate in summer 1992 on the terrace of the famous CERN cafeteria. In the summer of 2001 we returned to the subject to find that our views still diverged and decided to explain our current positions. LBO develops the traditional approach with three constants, GV argues in favor of just two, while MJD advocates zero.

  3. The Origin of the Constant Carbohydrate Diet

    Directory of Open Access Journals (Sweden)

    Charles Herbert Read

    2009-01-01

    Full Text Available The Constant Carbohydrate diet, based entirely on carbohydrate exchanges, is now widely used in the dietary treatment of diabetes mellitus. Being based on sound scientific principles and simple in design, the Constant Carabohydrate diet is appropriate for all those having diabetes mellitus, young or old, no matter their ethncity. This report describes why and how it was developed in 1951. Its simplicity makes it adaptable to all ethnic diets.

  4. The Origin of the Constant Carbohydrate Diet

    Directory of Open Access Journals (Sweden)

    Read CharlesHerbert

    2008-01-01

    Full Text Available The Constant Carbohydrate diet, based entirely on carbohydrate exchanges, is now widely used in the dietary treatment of diabetes mellitus. Being based on sound scientific principles and simple in design, the Constant Carabohydrate diet is appropriate for all those having diabetes mellitus, young or old, no matter their ethncity. This report describes why and how it was developed in 1951. Its simplicity makes it adaptable to all ethnic diets.

  5. Compact phase space, cosmological constant, discrete time

    CERN Document Server

    Rovelli, Carlo

    2015-01-01

    We study the quantization of geometry in the presence of a cosmological constant, using a discretiza- tion with constant-curvature simplices. Phase space turns out to be compact and the Hilbert space finite dimensional for each link. Not only the intrinsic, but also the extrinsic geometry turns out to be discrete, pointing to discreetness of time, in addition to space. We work in 2+1 dimensions, but these results may be relevant also for the physical 3+1 case.

  6. Inflationary Phase with Time Varying Fundamental Constants

    CERN Document Server

    Berman, M S; Berman, Marcelo S.; Trevisan, Luis A.

    2002-01-01

    Following Barrow, and Barrow and collaborators, we find a cosmological JBD model, with varying speed of light and varying fine structure constant, where the deceleration parameter is -1,causing acceleration of the Universe.Indeed, we have an exponential inflationary phase. Plancks time, energy, length,etc.,might have had different numerical values in the past, than those available in the litterature, due to the varying values for speed of light, and gravitational constant.

  7. Beyond lensing by the cosmological constant

    CERN Document Server

    Faraoni, Valerio

    2016-01-01

    The long-standing problem of whether the cosmological constant affects directly the deflection of light caused by a gravitational lens is reconsidered. We use a new approach based on the Hawking quasilocal mass of a sphere grazed by light rays and on its splitting into local and cosmological parts. Previous literature restricted to the cosmological constant is extended to any form of dark energy accelerating the universe in which the gravitational lens is embedded.

  8. Beyond lensing by the cosmological constant

    Science.gov (United States)

    Faraoni, Valerio; Lapierre-Léonard, Marianne

    2017-01-01

    The long-standing problem of whether the cosmological constant affects directly the deflection of light caused by a gravitational lens is reconsidered. We use a new approach based on the Hawking quasilocal mass of a sphere grazed by light rays and on its splitting into local and cosmological parts. Previous literature restricted to the cosmological constant is extended to any form of dark energy accelerating the universe in which the gravitational lens is embedded.

  9. A constant elasticity of profit production function

    OpenAIRE

    Beard, Rodney

    2007-01-01

    Impact analysis of changes in production inputs may be simplified if one can apply a constant adjustment factor to profit. In particular, if a production function can be found for which the elasticity of profit is constant and this function has desirable properties, then one can use the input elasticity of profit to study the impact of input changes on profit. In this paper such a production function is derived from first principles.

  10. RNA structure and scalar coupling constants

    Energy Technology Data Exchange (ETDEWEB)

    Tinoco, I. Jr.; Cai, Z.; Hines, J.V.; Landry, S.M.; SantaLucia, J. Jr.; Shen, L.X.; Varani, G. [Univ. of California, Berkeley, CA (United States)

    1994-12-01

    Signs and magnitudes of scalar coupling constants-spin-spin splittings-comprise a very large amount of data that can be used to establish the conformations of RNA molecules. Proton-proton and proton-phosphorus splittings have been used the most, but the availability of {sup 13}C-and {sup 15}N-labeled molecules allow many more coupling constants to be used for determining conformation. We will systematically consider the torsion angles that characterize a nucleotide unit and the coupling constants that depend on the values of these torsion angles. Karplus-type equations have been established relating many three-bond coupling constants to torsion angles. However, one- and two-bond coupling constants can also depend on conformation. Serianni and coworkers measured carbon-proton coupling constants in ribonucleosides and have calculated their values as a function of conformation. The signs of two-bond coupling can be very useful because it is easier to measure a sign than an accurate magnitude.

  11. Johnson Type Bounds on Constant Dimension Codes

    CERN Document Server

    Xia, Shu-Tao

    2007-01-01

    Very recently, an operator channel was defined by Koetter and Kschischang when they studied random network coding. They also introduced constant dimension codes and demonstrated that these codes can be employed to correct errors and/or erasures over the operator channel. Constant dimension codes are equivalent to the so-called linear authentication codes introduced by Wang, Xing and Safavi-Naini when constructing distributed authentication systems in 2003. In this paper, we study constant dimension codes. It is shown that Steiner structures are optimal constant dimension codes achieving the Wang-Xing-Safavi-Naini bound. Furthermore, we show that constant dimension codes achieve the Wang-Xing-Safavi-Naini bound if and only if they are certain Steiner structures. Then, we derive two Johnson type upper bounds, say I and II, on constant dimension codes. The Johnson type bound II slightly improves on the Wang-Xing-Safavi-Naini bound. Finally, we point out that a family of known Steiner structures is actually a fam...

  12. Inflation with a constant rate of roll

    Science.gov (United States)

    Motohashi, Hayato; Starobinsky, Alexei A.; Yokoyama, Jun'ichi

    2015-09-01

    We consider an inflationary scenario where the rate of inflaton roll defined by ̈phi/H dot phi remains constant. The rate of roll is small for slow-roll inflation, while a generic rate of roll leads to the interesting case of 'constant-roll' inflation. We find a general exact solution for the inflaton potential required for such inflaton behaviour. In this model, due to non-slow evolution of background, the would-be decaying mode of linear scalar (curvature) perturbations may not be neglected. It can even grow for some values of the model parameter, while the other mode always remains constant. However, this always occurs for unstable solutions which are not attractors for the given potential. The most interesting particular cases of constant-roll inflation remaining viable with the most recent observational data are quadratic hilltop inflation (with cutoff) and natural inflation (with an additional negative cosmological constant). In these cases even-order slow-roll parameters approach non-negligible constants while the odd ones are asymptotically vanishing in the quasi-de Sitter regime.

  13. Reflection spectra from an accretion disc illuminated by a neutron star X-ray burst

    CERN Document Server

    Ballantyne, D R

    2004-01-01

    Recent time-resolved X-ray spectra of a neutron star undergoing a superburst revealed an Fe K line and edge consistent with reprocessing from the surrounding accretion disc. Here, we present models of X-ray reflection from a constant density slab illuminated by a blackbody, the spectrum emitted by a neutron star burst. The calculations predict a prominent Fe K line and a rich soft X-ray line spectrum which is superimposed on a strong free-free continuum. The lines slowly vanish as the ionization parameter of the slab is increased, but the free-free continuum remains dominant at energiesless than 1 keV. The reflection spectrum has a quasi-blackbody shape only at energies greater than 3 keV. If the incident blackbody is added to the reflection spectrum, the Fe K equivalent width varies between 100 and 300 eV depending on the ionization parameter and the temperature, kT, of the blackbody. The equivalent width is correlated with kT, and therefore we predict a strong Fe K line when an X-ray burst is at its brighte...

  14. Transport illumination: health risks for personnel and passengers

    Directory of Open Access Journals (Sweden)

    V.A. Kaptsov

    2016-09-01

    Full Text Available The hygienic aspects of the transport illumination and the risks of the negative impact of LED lighting on the health of operators, drivers and passengers have been investigated. The transport illumination is a subject of the longitudinal research of the light effect of the beam and signal lights on driver’s reaction and dazzle. The study of the vehicles’ light effect on passengers’ health was not carried out because for the illuminating of the passenger compartments the incandescent bulbs were used, the characteristics of which are well known. Increasing of the duration of trips, their intensity and the replacement of incandescent lamps to LED lamps makes these studies more urgent. Particular attention is drawn on the fact that the transport system transports millions of passengers and children who are regularly exposed to excessive doses of blue light. The blue light time exposure is more than an hour per trip within the city and more than 5 hours during travel between the cities. The specialists of N.M. Emanuel Institute of Biochemical Physics RAS have indicated that modern white LEDs have expressed emission band in blue spectrum 440-460 nm that is entirely attributable to the spectrum of action of retinal photochemical damage and its pigment epithelium. Such extensive emission poses a hazard to the eyes of children and adolescents, because their crystalline lenses are almost twice as transparent in the dark-blue and blue spectrum area than those in adults. Retinal photochemical damage develops in distant time and can cause gradual, irreversible visual impairment. The risks of negative impact especially increase in the application of blue LED for interior lighting passenger vehicles. It was demonstrated that at the retinal cells’ affection by the excessive dose of the blue light the consequences have delayed character. The results of the accelerated assessment of the retina damage in Japanese quils (Сoturnix japonica. The eyes of

  15. Solar illumination control of ionospheric outflow above polar cap arcs

    CERN Document Server

    Maes, L; De Keyser, J; Dandouras, I; Fear, R C; Fontaine, D; Haaland, S

    2016-01-01

    We measure the flux density, composition, and energy of outflowing ions above the polar cap, accelerated by quasi-static electric fields parallel to the magnetic field and associated with polar cap arcs, using Cluster. Mapping the spacecraft position to its ionospheric foot point, we analyze the dependence of these parameters on the solar zenith angle (SZA). We find a clear transition at SZA between We find a clear transition at SZA between $\\sim$94$^{\\circ}$ and $\\sim$107$^{\\circ}$, with the O$^{+}$ flux higher above the sunlit ionosphere. This dependence on the illumination of the local ionosphere indicates that significant O$^{+}$ upflow occurs locally above the polar ionosphere. The same is found for H$^{+}$, but to a lesser extent. This effect can result in a seasonal variation of the total ion upflow from the polar ionosphere. Furthermore, we show that low-magnitude field-aligned potential drops are preferentially observed above the sunlit ionosphere, suggesting a feedback effect of ionospheric conducti...

  16. Imaging of Phase Objects using Partially Coherent Illumination

    Energy Technology Data Exchange (ETDEWEB)

    Ravizza, F. L. [Univ. of Arizona, Tucson, AZ (United States)

    2013-01-01

    Screening high-power laser optics for light intensifying phase objects that cause laserinduced damage on downstream optics is critical to sustaining laser operation. Identifying such flaws on large-apertures is quite challenging since they are relatively small and invisible to conventional inspection methods. A Linescan Phase Differential Imaging (LPDI) system was developed to rapidly identify these flaws on large-aperture optics within a single full-aperture dark-field image. We describe a two-step production phase object screening process consisting of LPDI mapping and image analysis, followed by high-resolution interferometry and propagation based evaluation of the downstream damage potential of identified flaws. An image simulation code capable of modeling the LPDI partially coherent illumination was used to optimize its phase object sensitivity.

  17. Resolving optical illumination distributions along an axially symmetric photodetecting fiber.

    Science.gov (United States)

    Sorin, Fabien; Lestoquoy, Guillaume; Danto, Sylvain; Joannopoulos, John D; Fink, Yoel

    2010-11-08

    Photodetecting fibers of arbitrary length with internal metal, semiconductor and insulator domains have recently been demonstrated. These semiconductor devices exhibit a continuous translational symmetry which presents challenges to the extraction of spatially resolved information. Here, we overcome this seemingly fundamental limitation and achieve the detection and spatial localization of a single incident optical beam at sub-centimeter resolution, along a one-meter fiber section. Using an approach that breaks the axial symmetry through the constuction of a convex electrical potential along the fiber axis, we demonstrate the full reconstruction of an arbitrary rectangular optical wave profile. Finally, the localization of up to three points of illumination simultaneously incident on a photodetecting fiber is achieved.

  18. Absolute Uniqueness of Phase Retrieval with Random Illumination

    CERN Document Server

    Fannjiang, Albert

    2011-01-01

    Random phase or amplitude illumination is proposed to remove at once all types of ambiguity, trivial or nontrivial, at once from phase retrieval. Almost sure irreducibility is proved for {\\em any} complex-valued object of arbitrary sparsity. While this irreducibility result can be viewed as a probabilistic version of the classical result by Bruck, Sodin and Hayes, it provides a new perspective and an effective method for achieving absolute uniqueness in phase retrieval for {\\em every} object, not just objects outside of a measure-zero set. In particular, almost sure absolute uniqueness is proved for complex-valued objects under a general two-point assumption. For objects of nonnegative real and imaginary parts, absolute uniqueness is proved to hold with probability exponentially close to unity as the object sparsity increases.

  19. Hacking commercial quantum cryptography systems by tailored bright illumination

    Science.gov (United States)

    Lydersen, Lars; Wiechers, Carlos; Wittmann, Christoffer; Elser, Dominique; Skaar, Johannes; Makarov, Vadim

    2010-10-01

    The peculiar properties of quantum mechanics allow two remote parties to communicate a private, secret key, which is protected from eavesdropping by the laws of physics. So-called quantum key distribution (QKD) implementations always rely on detectors to measure the relevant quantum property of single photons. Here we demonstrate experimentally that the detectors in two commercially available QKD systems can be fully remote-controlled using specially tailored bright illumination. This makes it possible to tracelessly acquire the full secret key; we propose an eavesdropping apparatus built from off-the-shelf components. The loophole is likely to be present in most QKD systems using avalanche photodiodes to detect single photons. We believe that our findings are crucial for strengthening the security of practical QKD, by identifying and patching technological deficiencies.

  20. Plane parallel radiance transport for global illumination in vegetation

    Energy Technology Data Exchange (ETDEWEB)

    Max, N.; Mobley, C.; Keating, B.; Wu, E.H.

    1997-01-05

    This paper applies plane parallel radiance transport techniques to scattering from vegetation. The leaves, stems, and branches are represented as a volume density of scattering surfaces, depending only on height and the vertical component of the surface normal. Ordinary differential equations are written for the multiply scattered radiance as a function of the height above the ground, with the sky radiance and ground reflectance as boundary conditions. They are solved using a two-pass integration scheme to unify the two-point boundary conditions, and Fourier series for the dependence on the azimuthal angle. The resulting radiance distribution is used to precompute diffuse and specular `ambient` shading tables, as a function of height and surface normal, to be used in rendering, together with a z-buffer shadow algorithm for direct solar illumination.

  1. Illuminating the Decision Path: The Yucca Mountain Site Recommendation

    Energy Technology Data Exchange (ETDEWEB)

    Knox, E.; Slothouber, L.

    2003-02-25

    On February 14, 2002, U.S. Secretary of Energy Spencer Abraham provided to the President the ''Recommendation by the Secretary of Energy Regarding the Suitability of the Yucca Mountain Site for a Repository Under the Nuclear Waste Policy Act of 1982.'' This Recommendation, along with supporting materials, complied with statutory requirements for communicating a site recommendation to the President, and it did more: in 49 pages, the Recommendation also spoke directly to the Nation, illuminating the methodology and considerations that led toward the decision to recommend the site. Addressing technical suitability, national interests, and public concerns, the Recommendation helped the public understand the potential risks and benefits of repository development and placed those risks and benefits in a meaningful national context.

  2. Direct illumination calibration of telescopes at the quantum precision limit

    Science.gov (United States)

    Barrelet, E.

    2016-10-01

    The electronic response of a telescope under direct illumination by a point-like light source is based on photon counting. With the data obtained using the SNDICE light source and the Megacam camera on the CFHT telescope, we show that the ultimate precision is only limited by the photon statistical fluctuation, which is below 1 ppm. A key feature of the analysis is the incorporation of diffuse light that interfers with specularly reflected light in the transmission model to explain the observed diffraction patterns. The effect of diffuse light, usually hidden conveniently in the Strehl ratio for an object at infinity, is characterized with a precision of 10 ppm. In particular, the spatial frequency representation provides some strong physical constraints and a practical monitoring of the roughness of various optical surfaces.

  3. Structured illumination for tomographic X-ray diffraction imaging.

    Science.gov (United States)

    Greenberg, Joel A; Hassan, Mehadi; Krishnamurthy, Kalyani; Brady, David

    2014-02-21

    Tomographic imaging of the molecular structure of an object is important for a variety of applications, ranging from medical and industrial radiography to security screening. X-ray diffraction imaging is the preeminent technique for performing molecular analysis of large volumes. Here we propose and demonstrate a new measurement architecture to improve the source and detector efficiency for diffraction imaging. In comparison with previous techniques, our approach reduces the required overall scan time by 1-2 orders of magnitude, which makes possible real-time scanning of a broad range of materials over a large volume using a table-top setup. This method, which relies on structuring spatially the illumination incident on an object moving relative to the X-ray source, is compatible with existing systems and has the potential to significantly enhance performance in an array of areas, such as medical diagnostic imaging and explosives detection.

  4. Direct illumination calibration of telescopes at the quantum precision limit

    CERN Document Server

    Barrelet, E

    2016-01-01

    The electronic response of a telescope under direct illumination by a point-like light source is based on photon counting. With the data obtained using the SNDICE light source and the Megacam camera on the CFHT telescope, we show that the ultimate precision is only limited by the photon statistical fluctuation, which is below 1 ppm. A key feature of the analysis is the incorporation of diffuse light that interferes with specularly reflected light in the transmission model to explain the observed diffraction patterns. The effect of diffuse light, usually hidden conveniently in the Strehl ratio for an object at infinity, is characterized with a precision of 10 ppm. In particular, the spatial frequency representation provides some strong physical constraints and a practical monitoring of the roughness of various optical surfaces.

  5. Spectral image reconstruction by a tunable LED illumination

    Science.gov (United States)

    Lin, Meng-Chieh; Tsai, Chen-Wei; Tien, Chung-Hao

    2013-09-01

    Spectral reflectance estimation of an object via low-dimensional snapshot requires both image acquisition and a post numerical estimation analysis. In this study, we set up a system incorporating a homemade cluster of LEDs with spectral modulation for scene illumination, and a multi-channel CCD to acquire multichannel images by means of fully digital process. Principal component analysis (PCA) and pseudo inverse transformation were used to reconstruct the spectral reflectance in a constrained training set, such as Munsell and Macbeth Color Checker. The average reflectance spectral RMS error from 34 patches of a standard color checker were 0.234. The purpose is to investigate the use of system in conjunction with the imaging analysis for industry or medical inspection in a fast and acceptable accuracy, where the approach was preliminary validated.

  6. X-ray total reflection mirrors for coherent illumination

    CERN Document Server

    Ishikawa, T; Yabashi, M; Souvorov, A; Yamauchi, K; Yamamura, K; Mimura, H; Saito, A; Mori, Y

    2002-01-01

    X-ray mirrors for coherent illumination demand much higher surface quality than is achievable with the conventional polishing techniques. Plasma chemical vaporization machining (CVM) and elastic emission machining (EEM) have been applied for x-ray mirror manufacturing. Figure error of a flat silicon single crystal mirrors made with CVM+EEM process was reduced to 2.0 nm peak-to-valley and 0.2 nm RMS. The machining process was also applied to make elliptical mirrors. One-dimensional focusing with a single elliptical mirror showed diffraction-limited properties with the focal width of 200 nm. Two-dimensional focusing with Kirkpatric-Baez configuration gave a focal spot size of 200 nm x 200 nm. (author)

  7. The color of night: Surface color perception under dim illuminations.

    Science.gov (United States)

    Pokorny, Joel; Lutze, Margaret; Cao, Dingcai; Zele, Andrew J

    2006-01-01

    Several studies document rudimentary color vision under dim illumination. Here, hue perceptions of paper color samples were determined for a wide range of light levels, including very low light levels where rods alone mediate vision. The appearances of 24 paper color samples from the OSA Uniform Color Scales were gauged under successively dimmer illuminations from 10-0.0003 Lux. Triads of samples were chosen representing each of eight basic color categories; red, pink, orange, yellow, green, blue, purple, and gray. Samples within each triad varied in lightness. Observers sorted samples into groups that they could categorize with specific color names. Above 0.32 Lux, observers sorted the samples into the originally chosen color groups with few exceptions. For 0.1-0.01 Lux, the red and orange samples were usually correctly identified as either red or orange. The remaining samples tended to be grouped into two categories, associated with the scotopic sample reflectance. The lowest reflectance samples were below threshold and were named black. The higher reflectance group was named predominately as green or blue-green (three observers; the fourth observer used blue or achromatic). At the three dimmest levels (< or = 0.0032 Lux) there continued to be conspicuous color percepts. Color categories were reliably assigned based on relative sample scotopic lightness. Of the samples above threshold, those with lower reflectance were classified as red or orange (all observers) and the higher reflectance samples as green or blue-green (three observers) or achromatic or blue (the fourth observer). Rods and L-cones presumably mediated color percepts at the intermediate light levels used in the study. At the three lowest light levels there were distinct color appearances mediated exclusively by rods. We speculate that at these light levels the visual system estimates probable colors based on prior natural experience.

  8. Mirror Illumination and Spillover Measurements of the Atacama Cosmology Telescope

    Science.gov (United States)

    Gallardo, Patricio; Dunner, Rolando; Wollack, Ed; Jerez-Hanckes, Carlos

    2012-01-01

    The Atacama Cosmology Telescope (ACT) is a 6 m telescope designed to map the Cosmic Microwave Background (CMB) simultaneously at 145 GHz, 220GHz and 280GHz, The receiver in ACT, the Millimeter Bolometer Array Camera, features 1000 TES bolometers in each band, The detector performance depends critically on the total optical loading, requiring the spmover contributions from the optics to be minimal. This inspired the use of a cold Lyot stop to limit the illumination of the primary and the use of guard rings surrounding the primary and secondary reflectors. Here, we present a direct measurement of the illumination aperture for both reflectors and of the attenuation level outside the main optical path. We used a 145 GHz, 1 m W source and a chopper wheel to produce a time-varying signal with a broad heam proflle, We sampled the response of the camera for different locations of the source, placed in front and beside the primary and secondary mirrors. The aperture of the primary was measured to be 5,72 plus or minus 0,17m in diameter (95 plus or minus 3% of its geometrical size), while the aperture of the secondary yielded 2 plus or minus 0.12m in diameter. Both apertures are consistent with the optical design. Comparing to previous measurements of the beam solid angle from planet observations, we estimate an optical efficiency of 72.3 plus or minus 4,8%. We found that the attenuation outside the primary aperture was -16 plus or minus 2dB, which is below the theoretical expectations, and -22 plus or minus 1 dB outside the secondary aperture, which is consistent with simulations. These results motivated the extension of the baffles surrounding the secondary mirror, with the following reduction in detector optical loading from 2,24 pW to 188pW.

  9. A 3-D fluorescence imaging system incorporating structured illumination technology

    Science.gov (United States)

    Antos, L.; Emord, P.; Luquette, B.; McGee, B.; Nguyen, D.; Phipps, A.; Phillips, D.; Helguera, M.

    2010-02-01

    A currently available 2-D high-resolution, optical molecular imaging system was modified by the addition of a structured illumination source, OptigridTM, to investigate the feasibility of providing depth resolution along the optical axis. The modification involved the insertion of the OptigridTM and a lens in the path between the light source and the image plane, as well as control and signal processing software. Projection of the OptigridTM onto the imaging surface at an angle, was resolved applying the Scheimpflug principle. The illumination system implements modulation of the light source and provides a framework for capturing depth resolved mages. The system is capable of in-focus projection of the OptigridTM at different spatial frequencies, and supports the use of different lenses. A calibration process was developed for the system to achieve consistent phase shifts of the OptigridTM. Post-processing extracted depth information using depth modulation analysis using a phantom block with fluorescent sheets at different depths. An important aspect of this effort was that it was carried out by a multidisciplinary team of engineering and science students as part of a capstone senior design program. The disciplines represented are mechanical engineering, electrical engineering and imaging science. The project was sponsored by a financial grant from New York State with equipment support from two industrial concerns. The students were provided with a basic imaging concept and charged with developing, implementing, testing and validating a feasible proof-of-concept prototype system that was returned to the originator of the concept for further evaluation and characterization.

  10. Environment-Dependent Fundamental Physical Constants

    CERN Document Server

    Terazawa, Hidezumi

    2012-01-01

    A theory of special inconstancy, in which some fundamental physical constants such as the fine-structure and gravitational constants may vary, is proposed in pregeometry. In the special theory of inconstancy, the \\alpha-G relation of \\alpha=3\\pi/[16ln(4\\pi/5GM_W^2)] between the varying fine-structure and gravitaional constants (where M_W is the charged weak boson mass) is derived from the hypothesis that both of these constants are related to the same fundamental length scale in nature. Furthermore, it leads to the prediction of dot{{\\alpha}}/\\alpha=(-0.8\\pm2.5)\\times10^{-14}yr^{-1} from the most precise limit of dot{G}/G=(-0.6\\pm2.0)\\times10^{-12}yr^{-1} by Thorsett, which is not only consistent with the recent observation of dot{{\\alpha}}/\\alpha=(0.5\\pm0.5)\\times10^{-14}yr^{-1} by Webb et al. but also feasible for future experimental tests. Also a theory of general inconstancy, in which any fundamental physical constants may vary, is proposed in "more general relativity", by assuming that the space-time is ...

  11. Athermal nonlinear elastic constants of amorphous solids.

    Science.gov (United States)

    Karmakar, Smarajit; Lerner, Edan; Procaccia, Itamar

    2010-08-01

    We derive expressions for the lowest nonlinear elastic constants of amorphous solids in athermal conditions (up to third order), in terms of the interaction potential between the constituent particles. The effect of these constants cannot be disregarded when amorphous solids undergo instabilities such as plastic flow or fracture in the athermal limit; in such situations the elastic response increases enormously, bringing the system much beyond the linear regime. We demonstrate that the existing theory of thermal nonlinear elastic constants converges to our expressions in the limit of zero temperature. We motivate the calculation by discussing two examples in which these nonlinear elastic constants play a crucial role in the context of elastoplasticity of amorphous solids. The first example is the plasticity-induced memory that is typical to amorphous solids (giving rise to the Bauschinger effect). The second example is how to predict the next plastic event from knowledge of the nonlinear elastic constants. Using the results of our calculations we derive a simple differential equation for the lowest eigenvalue of the Hessian matrix in the external strain near mechanical instabilities; this equation predicts how the eigenvalue vanishes at the mechanical instability and the value of the strain where the mechanical instability takes place.

  12. MID IR Optical Constants of Orthopyroxenes.

    Science.gov (United States)

    Rucks, M.; Glotch, T. D.

    2014-12-01

    Orthopyroxenes are common rock forming minerals that are present on many planetary bodies as well as meteorites and cosmic dust. The presence of these minerals can give implications to the petrogenic history of these planetary bodies. Optical constants, n and k, are essential inputs into radiative transfer models which are used in remote sensing techniques. [1,2] While optical constants have been determined for orthopyroxenes with high Mg content, Fe rich orthopyroxenes have not been studied as extensively. [3] The goal of this research is to determine the optical constants of orthopyroxenes ranging in composition along the enstatite-ferrosilite solid solution, to gain a more comprehensive list of these values. Specular reflectance spectra, in the range of 250-4000 cm-1, were obtained for several oriented single crystal samples at three crystallographic orientations for each sample. Optical constants, n and k, were then derived through modeling of measured spectra using the Matlab lsqcurvefit function. Preveous work has identified the optical constants for two Mg rich natural samples, enstatite and hypersthene. Current research applies the above methodology to synthetic ferrosilite, the Fe rich end-member of the orthopyroxene mineral series. Future studies will provide a more comprehensive look at the variation of n and k as a function of the Mg:Fe composition. [1] Arnold, J.A. et al (2013) (under review), [2] Glotch, T.D. and Rossman, G.R. (2009) Icarus, [3] Jäger, C. et al (1998) Astron. Astrophys.

  13. Imaging cortical absorption, scattering, and hemodynamic response during ischemic stroke using spatially modulated near-infrared illumination

    Science.gov (United States)

    Abookasis, David; Lay, Christopher C.; Mathews, Marlon S.; Linskey, Mark E.; Frostig, Ron D.; Tromberg, Bruce J.

    2009-03-01

    We describe a technique that uses spatially modulated near-infrared (NIR) illumination to detect and map changes in both optical properties (absorption and reduced scattering parameters) and tissue composition (oxy- and deoxyhemoglobin, total hemoglobin, and oxygen saturation) during acute ischemic injury in the rat barrel cortex. Cerebral ischemia is induced using an open vascular occlusion technique of the middle cerebral artery (MCA). Diffuse reflected NIR light (680 to 980 nm) from the left parietal somatosensory cortex is detected by a CCD camera before and after MCA occlusion. Monte Carlo simulations are used to analyze the spatial frequency dependence of the reflected light to predict spatiotemporal changes in the distribution of tissue absorption and scattering properties in the brain. Experimental results from seven rats show a 17+/-4.7% increase in tissue concentration of deoxyhemoglobin and a 45+/-3.1, 23+/-5.4, and 21+/-2.2% decrease in oxyhemoglobin, total hemoglobin concentration and cerebral tissue oxygen saturation levels, respectively, 45 min following induction of cerebral ischemia. An ischemic index (Iisch=ctHHb/ctO2Hb) reveals an average of more then twofold contrast after MCAo. The wavelength-dependence of the reduced scattering (i.e., scatter power) decreased by 35+/-10.3% after MCA occlusion. Compared to conventional CCD-based intrinsic signal optical imaging (ISOI), the use of structured illumination and model-based analysis allows for generation of separate maps of light absorption and scattering properties as well as tissue hemoglobin concentration. This potentially provides a powerful approach for quantitative monitoring and imaging of neurophysiology and metabolism with high spatiotemporal resolution.

  14. Enhanced retinal modeling for face recognition and facial feature point detection under complex illumination conditions

    Science.gov (United States)

    Cheng, Yong; Li, Zuoyong; Jiao, Liangbao; Lu, Hong; Cao, Xuehong

    2016-07-01

    We improved classic retinal modeling to alleviate the adverse effect of complex illumination on face recognition and extracted robust image features. Our improvements on classic retinal modeling included three aspects. First, a combined filtering scheme was applied to simulate functions of horizontal and amacrine cells for accurate local illumination estimation. Second, we developed an optimal threshold method for illumination classification. Finally, we proposed an adaptive factor acquisition model based on the arctangent function. Experimental results on the combined Yale B; the Carnegie Mellon University poses, illumination, and expression; and the Labeled Face Parts in the Wild databases show that the proposed method can effectively alleviate illumination difference of images under complex illumination conditions, which is helpful for improving the accuracy of face recognition and that of facial feature point detection.

  15. Tracking energy transfer between light harvesting complex 2 and 1 in photosynthetic membranes grown under high and low illumination.

    Science.gov (United States)

    Lüer, Larry; Moulisová, Vladimíra; Henry, Sarah; Polli, Dario; Brotosudarmo, Tatas H P; Hoseinkhani, Sajjad; Brida, Daniele; Lanzani, Guglielmo; Cerullo, Giulio; Cogdell, Richard J

    2012-01-31

    Energy transfer (ET) between B850 and B875 molecules in light harvesting complexes LH2 and LH1/RC (reaction center) complexes has been investigated in membranes of Rhodopseudomonas palustris grown under high- and low-light conditions. In these bacteria, illumination intensity during growth strongly affects the type of LH2 complexes synthesized, their optical spectra, and their amount of energetic disorder. We used a specially built femtosecond spectrometer, combining tunable narrowband pump with broadband white-light probe pulses, together with an analytical method based on derivative spectroscopy for disentangling the congested transient absorption spectra of LH1 and LH2 complexes. This procedure allows real-time tracking of the forward (LH2 → LH1) and backward (LH2←LH1) ET processes and unambiguous determination of the corresponding rate constants. In low-light grown samples, we measured lower ET rates in both directions with respect to high-light ones, which is explained by reduced spectral overlap between B850 and B875 due to partial redistribution of oscillator strength into a higher energetic exciton transition. We find that the low-light adaptation in R. palustris leads to a reduced elementary backward ET rate, in accordance with the low probability of two simultaneous excitations reaching the same LH1/RC complex under weak illumination. Our study suggests that backward ET is not just an inevitable consequence of vectorial ET with small energetic offsets, but is in fact actively managed by photosynthetic bacteria.

  16. Single-image phase retrieval using an edge illumination X-ray phase-contrast imaging setup

    Energy Technology Data Exchange (ETDEWEB)

    Diemoz, Paul C., E-mail: p.diemoz@ucl.ac.uk; Vittoria, Fabio A. [University College London, London WC1 E6BT (United Kingdom); Research Complex at Harwell, Oxford Harwell Campus, Didcot OX11 0FA (United Kingdom); Hagen, Charlotte K.; Endrizzi, Marco [University College London, London WC1 E6BT (United Kingdom); Coan, Paola [Ludwig-Maximilians-University, Munich 81377 (Germany); Ludwig-Maximilians-University, Garching 85748 (Germany); Brun, Emmanuel [Ludwig-Maximilians-University, Garching 85748 (Germany); European Synchrotron Radiation Facility, Grenoble 38043 (France); Wagner, Ulrich H.; Rau, Christoph [Diamond Light Source, Harwell Oxford Campus, Didcot OX11 0DE (United Kingdom); Robinson, Ian K. [Research Complex at Harwell, Oxford Harwell Campus, Didcot OX11 0FA (United Kingdom); London Centre for Nanotechnology, London WC1 H0AH (United Kingdom); Bravin, Alberto [European Synchrotron Radiation Facility, Grenoble 38043 (France); Olivo, Alessandro [University College London, London WC1 E6BT (United Kingdom); Research Complex at Harwell, Oxford Harwell Campus, Didcot OX11 0FA (United Kingdom)

    2015-06-25

    A method enabling the retrieval of thickness or projected electron density of a sample from a single input image is derived theoretically and successfully demonstrated on experimental data. A method is proposed which enables the retrieval of the thickness or of the projected electron density of a sample from a single input image acquired with an edge illumination phase-contrast imaging setup. The method assumes the case of a quasi-homogeneous sample, i.e. a sample with a constant ratio between the real and imaginary parts of its complex refractive index. Compared with current methods based on combining two edge illumination images acquired in different configurations of the setup, this new approach presents advantages in terms of simplicity of acquisition procedure and shorter data collection time, which are very important especially for applications such as computed tomography and dynamical imaging. Furthermore, the fact that phase information is directly extracted, instead of its derivative, can enable a simpler image interpretation and be beneficial for subsequent processing such as segmentation. The method is first theoretically derived and its conditions of applicability defined. Quantitative accuracy in the case of homogeneous objects as well as enhanced image quality for the imaging of complex biological samples are demonstrated through experiments at two synchrotron radiation facilities. The large range of applicability, the robustness against noise and the need for only one input image suggest a high potential for investigations in various research subjects.

  17. The case for the cosmological constant

    Indian Academy of Sciences (India)

    Varun Sahni

    2000-07-01

    I present a short overview of current observational results and theoretical models for a cosmological constant. The main motivation for invoking a small cosmological constant (or -term) at the present epoch has to do with observations of high redshift Type Ia supernovae which suggest an accelerating universe. A flat accelerating universe is strongly favoured by combining supernovae observations with observations of CMB anisotropies on degree scales which give the `best-fit’ values ≃ 0.7 and m ≃ 0.3. A time dependent cosmological -term can be generated by scalar field models with exponential and power law potentials. Some of these models can alleviate the `fine tuning’ problem which faces the cosmological constant.

  18. Bounds on Gromov Hyperbolicity Constant in Graphs

    Indian Academy of Sciences (India)

    José M Rodríguez; José M Sigarreta

    2012-02-01

    If is a geodesic metric space and 1,2,3 $\\in$ , a geodesic triangle ={1,2,3} is the union of the three geodesics [1,2], [2,3] and [31] in . The space is -hyperbolic (in the Gromov sense) if any side of is contained in a -neighborhood of the union of two other sides, for every geodesic triangle in . If is hyperbolic, we denote by () the sharp hyperbolicity constant of , i.e. ()=$inf{$≥ 0$ : is -hyperbolic}. In this paper we relate the hyperbolicity constant of a graph with some known parameters of the graph, as its independence number, its maximum and minimum degree and its domination number. Furthermore, we compute explicitly the hyperbolicity constant of some class of product graphs.

  19. Construction and experimental testing of the constant-bandwidth constant-temperature anemometer.

    Science.gov (United States)

    Ligeza, P

    2008-09-01

    A classical constant-temperature hot-wire anemometer enables the measurement of fast-changing flow velocity fluctuations, although its transmission bandwidth is a function of measured velocity. This may be a source of significant dynamic errors. Incorporation of an adaptive controller into the constant-temperature system results in hot-wire anemometer operating with a constant transmission bandwidth. The construction together with the results of experimental testing of a constant-bandwidth hot-wire anemometer prototype are presented in this article. During the testing, an approximately constant transmission bandwidth of the anemometer was achieved. The constant-bandwidth hot-wire anemometer can be used in measurements of high-frequency variable flows characterized by a wide range of velocity changes.

  20. Investigation of Constant Temperature Hot-wire System Response using Laser Pulse

    Science.gov (United States)

    Jaffa, Nicholas; Morris, Scott; Cameron, Joshua

    2016-11-01

    Constant temperature hot-wire systems use a Wheatstone bridge and feedback amplifier circuit to maintain a constant average temperature across the wire yielding frequency responses of order 100 kHz. This high frequency response allows hot-wires to be used extensively for aerodynamic measurements in high speed flows and uncertainty at these high frequencies can be difficult to diagnose. The standard frequency response check for constant temperature hot-wires uses an electronic pulse across the circuit to check the electronic feedback circuit response time, but does not account for the impact of the heat transfer along the wire. In order to investigate the frequency response of the entire constant temperature hot-wire system, including the heat transfer along the wire, a novel method was developed using a pulsed PIV laser focused to illuminate only the hot-wire. The laser pulse duration was effectively an instantaneous change in wire surface temperature through radiation. A hot-wire was placed in a uniform open calibration jet for a range of flow conditions. The response of the entire hot-wire system was observed across a range of conditions including changes in flow, wire temperature, and thermal boundary conditions and compared with the electronic pulse test.