WorldWideScience

Sample records for consecutive imaging studies

  1. The correlation between lacunes and microbleeds on magnetic resonance imaging in consecutive 180 patients

    International Nuclear Information System (INIS)

    Tajitsu, Kenichiro; Yokoyama, Shunichi; Taguci, Yuichiro; Kusumoto, Kazuhiro

    2006-01-01

    Microbleeds on T2 * -weighted magnetic resonance imaging (MRI) represent a hemorrhagic type of small vessel disease. Small vessel disease causes both intracerebral hemorrhages and lacunar infarctions. We studied clinical background and MRI findings of the patients to clarify the correlation between microbleeds and lacunes. This study consisted of 180 consecutive patients who underwent brain MRI using 1.5T system in our hospital for a year. We obtained T2 * -weighted gradient-echo imaging as well as T1 and T2-weighted images. We statistically identified the factors related to the presence of microbleeds in all patients. The distribution of lacunes and microbleeds on MRI was compared to clarify the correlation of the lesions in the patients who had both lesions. The overall prevalence of microbleeds was 41.1% (74 of 180 patients). Logistic regression analysis indicated that previous stroke, leukoaraiosis and lacunes were significantly correlated with microbleeds. In the patients who have both microbleeds and lacunes, lesions are tended to locate in thalamus and basal ganglia, especially incidence of lacunes are significantly greater compared with other regions. Thirty-six of 398 lesions (9.05%) diagnosed as lacunes with T1- and T2-weighted imaging were demonstrated as microbleeds with T2 * -weighted gradient-echo imaging. Lacunes, leukoaraiosis as a hypertensive change on MRI had statistically significant correlation with the presence of microbleeds. T2 * -weighted gradient-echo imaging should be included in the imaging protocol for cerebrovascular disease, because T1- and T2-weighted imaging recognizing some of the microbleeds as lacunar infarction. (author)

  2. Consecutive Acupuncture Stimulations Lead to Significantly Decreased Neural Responses

    NARCIS (Netherlands)

    Yeo, S.; Choe, I.H.; Noort, M.W.M.L. van den; Bosch, M.P.C.; Lim, S.

    2010-01-01

    Objective: Functional magnetic resonance imaging (fMRI), in combination with block design paradigms with consecutive acupuncture stimulations, has often been used to investigate the neural responses to acupuncture. In this study, we investigated whether previous acupuncture stimulations can affect

  3. Hibernoma: MRI features in eight consecutive cases

    International Nuclear Information System (INIS)

    Lee, J.C.; Gupta, A.; Saifuddin, A.; Flanagan, A.; Skinner, J.A.; Briggs, T.W.R.; Cannon, S.R.

    2006-01-01

    Aim: To describe the preoperative magnetic resonance imaging findings of eight histologically-proven cases of hibernoma. Materials and methods: The site, size, and signal characteristics of eight consecutive hibernomas were retrospectively assessed on T1-weighted spin-echo and short T1 inversion recovery (STIR)/fat-saturated T2-weighted fast spin echo magnetic resonance images. Four patients also had gadolinium-enhanced fat-saturated T1-weighted spin echo imaging. Patient age and sex, and duration of symptoms were recorded. Results: Three female and five male patients with an average age 36 years (range 16-53 years) were included. Seven lesions occurred in the thigh, four in the anterior compartment and three in the posterior compartment. One lesion occurred superficial to the scapula. All cases demonstrated common magnetic resonance imaging findings of a well-defined, heterogeneous mass, slightly or clearly hypo-intense to subcutaneous fat on T1-weighted spin-echo images, with prominent thin low signal bands throughout the tumour. The lesions failed to fully suppress on STIR or fat-saturated T2-weighted images. Only one of the four contrast-enhanced studies demonstrated increased vascularity in the tumour. Conclusion: The MRI findings of a lesion that is diffusely slightly hypointense to surrounding subcutaneous fat, should prompt the operator to consider hibernoma in the differential diagnosis

  4. Signal-to-noise ratio measurement in parallel MRI with subtraction mapping and consecutive methods

    International Nuclear Information System (INIS)

    Imai, Hiroshi; Miyati, Tosiaki; Ogura, Akio; Doi, Tsukasa; Tsuchihashi, Toshio; Machida, Yoshio; Kobayashi, Masato; Shimizu, Kouzou; Kitou, Yoshihiro

    2008-01-01

    When measuring the signal-to-noise ratio (SNR) of an image the used parallel magnetic resonance imaging, it was confirmed that there was a problem in the application of past SNR measurement. With the method of measuring the noise from the background signal, SNR with parallel imaging was higher than that without parallel imaging. In the subtraction method (NEMA standard), which sets a wide region of interest, the white noise was not evaluated correctly although SNR was close to the theoretical value. We proposed two techniques because SNR in parallel imaging was not uniform according to inhomogeneity of the coil sensitivity distribution and geometry factor. Using the first method (subtraction mapping), two images were scanned with identical parameters. The SNR in each pixel divided the running mean (7 by 7 pixels in neighborhood) by standard deviation/√2 in the same region of interest. Using the second (consecutive) method, more than fifty consecutive scans of the uniform phantom were obtained with identical scan parameters. Then the SNR was calculated from the ratio of mean signal intensity to the standard deviation in each pixel on a series of images. Moreover, geometry factors were calculated from SNRs with and without parallel imaging. The SNR and geometry factor using parallel imaging in the subtraction mapping method agreed with those of the consecutive method. Both methods make it possible to obtain a more detailed determination of SNR in parallel imaging and to calculate the geometry factor. (author)

  5. On the last digits of consecutive primes

    OpenAIRE

    Holt, Fred B.

    2016-01-01

    Recently Oliver and Soundararajan made conjectures based on computational enumerations about the frequency of occurrence of pairs of last digits for consecutive primes. By studying Eratosthenes sieve, we have identified discrete dynamic systems that exactly model the populations of gaps across stages of Eratosthenes sieve. Our models provide some insight into the observed biases in the occurrences of last digits in consecutive primes, and the models suggest that the biases will ultimately be ...

  6. Labtracker+, a medical smartphone app for the interpretation of consecutive laboratory results: an external validation study.

    Science.gov (United States)

    Hilderink, Judith M; Rennenberg, Roger J M W; Vanmolkot, Floris H M; Bekers, Otto; Koopmans, Richard P; Meex, Steven J R

    2017-09-01

    When monitoring patients over time, clinicians may struggle to distinguish 'real changes' in consecutive blood parameters from so-called natural fluctuations. In practice, they have to do so by relying on their clinical experience and intuition. We developed Labtracker+ , a medical app that calculates the probability that an increase or decrease over time in a specific blood parameter is real, given the time between measurements. We presented patient cases to 135 participants to examine whether there is a difference between medical students, residents and experienced clinicians when it comes to interpreting changes between consecutive laboratory results. Participants were asked to interpret if changes in consecutive laboratory values were likely to be 'real' or rather due to natural fluctuations. The answers of the study participants were compared with the calculated probabilities by the app Labtracker+ and the concordance rates were assessed. Medical students (n=92), medical residents from the department of internal medicine (n=19) and internists (n=24) at a Dutch University Medical Centre. Concordance rates between the study participants and the calculated probabilities by the app Labtracker+ were compared. Besides, we tested whether physicians with clinical experience scored better concordance rates with the app Labtracker+ than inexperienced clinicians. Medical residents and internists showed significantly better concordance rates with the calculated probabilities by the app Labtracker+ than medical students, regarding their interpretation of differences between consecutive laboratory results (p=0.009 and p<0.001, respectively). The app Labtracker+ could serve as a clinical decision tool in the interpretation of consecutive laboratory test results and could contribute to rapid recognition of parameter changes by physicians. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial

  7. Recurrent pregnancy loss: what is the impact of consecutive versus non-consecutive losses?

    Science.gov (United States)

    Egerup, P; Kolte, A M; Larsen, E C; Krog, M; Nielsen, H S; Christiansen, O B

    2016-11-01

    Is there a different prognostic impact for consecutive and non-consecutive early pregnancy losses in women with secondary recurrent pregnancy loss (RPL)? Only consecutive early pregnancy losses after the last birth have a statistically significant negative prognostic impact in women with secondary RPL. The risk of a new pregnancy loss increases with the number of previous pregnancy losses in patients with RPL. Second trimester losses seem to exhibit a stronger negative impact than early losses. It is unknown whether the sequence of pregnancy losses plays a role for the prognosis in patients with a prior birth. This retrospective cohort study of pregnancy outcome in patients with unexplained secondary RPL included in three previously published, Danish double-blinded placebo-controlled trials of intravenous immunoglobulin (IvIg) conducted from 1991 to 2014. No other treatments were given. Patients with documented explained pregnancy losses (ectopic pregnancies and aneuploid miscarriages) were excluded. Of the 168 patients included in the trials, 127 had secondary RPL and experienced a subsequent live birth or unexplained pregnancy loss in the first pregnancy after giving informed consent to participate in the trials (the index pregnancy). Data analyzed by multivariate analysis included the independent variables age, the number of early pregnancy losses before and after the last birth, respectively and a second trimester pregnancy loss before or after the last birth, respectively. The outcome variable was unexplained loss in the index pregnancy. In patients with secondary RPL, both a late and each early loss before the last birth did not significantly influence the risk of a new pregnancy loss in the index pregnancy: incidence rate ratio (IRR) 1.31 (95% CI 0.62-2.77) and IRR 0.88 (95% CI 0.70-1.11), respectively. In contrast, the impact on risk of pregnancy loss conferred by a late and by each early pregnancy loss occurring after the birth was significant: IRR 2

  8. a New Approach for Progressive Dense Reconstruction from Consecutive Images Based on Prior Low-Density 3d Point Clouds

    Science.gov (United States)

    Lari, Z.; El-Sheimy, N.

    2017-09-01

    In recent years, the increasing incidence of climate-related disasters has tremendously affected our environment. In order to effectively manage and reduce dramatic impacts of such events, the development of timely disaster management plans is essential. Since these disasters are spatial phenomena, timely provision of geospatial information is crucial for effective development of response and management plans. Due to inaccessibility of the affected areas and limited budget of first-responders, timely acquisition of the required geospatial data for these applications is usually possible only using low-cost imaging and georefencing sensors mounted on unmanned platforms. Despite rapid collection of the required data using these systems, available processing techniques are not yet capable of delivering geospatial information to responders and decision makers in a timely manner. To address this issue, this paper introduces a new technique for dense 3D reconstruction of the affected scenes which can deliver and improve the needed geospatial information incrementally. This approach is implemented based on prior 3D knowledge of the scene and employs computationally-efficient 2D triangulation, feature descriptor, feature matching and point verification techniques to optimize and speed up 3D dense scene reconstruction procedure. To verify the feasibility and computational efficiency of the proposed approach, an experiment using a set of consecutive images collected onboard a UAV platform and prior low-density airborne laser scanning over the same area is conducted and step by step results are provided. A comparative analysis of the proposed approach and an available image-based dense reconstruction technique is also conducted to prove the computational efficiency and competency of this technique for delivering geospatial information with pre-specified accuracy.

  9. Forbidden Structures for Planar Perfect Consecutively Colourable Graphs

    Directory of Open Access Journals (Sweden)

    Borowiecka-Olszewska Marta

    2017-05-01

    Full Text Available A consecutive colouring of a graph is a proper edge colouring with posi- tive integers in which the colours of edges incident with each vertex form an interval of integers. The idea of this colouring was introduced in 1987 by Asratian and Kamalian under the name of interval colouring. Sevast- janov showed that the corresponding decision problem is NP-complete even restricted to the class of bipartite graphs. We focus our attention on the class of consecutively colourable graphs whose all induced subgraphs are consecutively colourable, too. We call elements of this class perfect consecutively colourable to emphasise the conceptual similarity to perfect graphs. Obviously, the class of perfect consecutively colourable graphs is induced hereditary, so it can be characterized by the family of induced forbidden graphs. In this work we give a necessary and sufficient conditions that must be satisfied by the generalized Sevastjanov rosette to be an induced forbid- den graph for the class of perfect consecutively colourable graphs. Along the way, we show the exact values of the deficiency of all generalized Sevastjanov rosettes, which improves the earlier known estimating result. It should be mentioned that the deficiency of a graph measures its closeness to the class of consecutively colourable graphs. We motivate the investigation of graphs considered here by showing their connection to the class of planar perfect consecutively colourable graphs.

  10. Differentiation of hypertensive heart disease with hypertrophy and hepertrophic cardiomyopathy using consecutive time-course images of Gd-DTPA enhanced MRI

    International Nuclear Information System (INIS)

    Ochiai, Kouichi; Isibashi, Yutaka; Shimada, Toshio; Tsukihashi, Hironori; Sato, Hidetoshi; Kitamura, Jun; Morioka, Shigefumi; Kawamitsu, Hideaki; Sugimura, Kazuro

    1996-01-01

    We used consecutive time-course Gd-DTPA contrast magnetic resonance images to differentiate hypertrophic cardiomyopathy (HCM) from hypertensive heart disease with hypertrophy (HHD). Seventeen patients with HCM, 6 patients with HHD and 5 normal subjects (control) were studied. ECG-gated MRI with 1.5T system was performed before and after intravenous injection of Gd-DTPA (0.1mmol/Kg) using spin echo sequence. Gd-DTPA enhanced MRI was repeated every 10 to 55 minutes. We measured signal intensity (SI) of midleft ventricular myocardium and skeletal muscle, and then calculated the ratio between myocardial SI and skeletal muscle SI. Myocardium was enhanced by Gd-DTPA in all patients. However, there was difference in the decay of enhancement effect by Gd-DTPA between HCM and HHD. The decay in HCM was more slowly than in both HHD and control. There was no difference in the decay between HHD and control. The difference in the decay between HCM and HHD became significant 25 minutes after Gd-DTPA injection and lasted until 55 minutes. We conclude that the time-course of the decay of enhancement effect by Gd-DTPA is helpful to differentiate HCM from HHD and the difference of the decay might reflect structural changes of myocardium. (author)

  11. What is the preferred number of consecutive night shifts? results from a crossover intervention study among police officers in Denmark.

    Science.gov (United States)

    Nabe-Nielsen, Kirsten; Jensen, Marie Aarrebo; Hansen, Åse Marie; Kristiansen, Jesper; Garde, Anne Helene

    2016-10-01

    Among police officers in Denmark, we studied (i) how many consecutive night shifts participants preferred at baseline; (ii) preferences regarding three intervention conditions (two, four, and seven consecutive night shifts followed by the same number of days off/day shifts: '2 + 2', '4 + 4', '7 + 7') at follow-up; (iii) characteristics of participants preferring each of these intervention conditions. Questionnaire data from a crossover intervention study were used (baseline: n = 73; follow-up: n = 68). At baseline, 49% preferred four consecutive night shifts. At follow-up, 57% preferred '4 + 4', 26% preferred '2 + 2' and 26% preferred '7 + 7'. Participants, who preferred longer spells of night work experienced that night work was less demanding, found it easier to sleep at different times of the day, and were more frequently evening types compared with participants who preferred shorter spells of night work. The participants' preferences are likely to be influenced by their previous shift work experience. Practitioner Summary: We investigated police officers' preferences regarding the number of consecutive night shifts. The majority preferred four consecutive night shifts. Those who preferred the longer spells of night work found night work less demanding, found it easier to sleep at different times of the day, and were more frequently evening types.

  12. Bilirubin-Induced Neurological Dysfunction: A Clinico-Radiological-Neurophysiological Correlation in 30 Consecutive Children.

    Science.gov (United States)

    van Toorn, Ronald; Brink, Philip; Smith, Johan; Ackermann, Christelle; Solomons, Regan

    2016-12-01

    The clinical expression of bilirubin-induced neurological dysfunction varies according to severity and location of the disease. Definitions have been proposed to describe different bilirubin-induced neurological dysfunction subtypes. Our objective was to describe the severity and clinico-radiological-neurophysiological correlation in 30 consecutive children with bilirubin-induced neurological dysfunction seen over a period of 5 years. Thirty children exposed to acute neonatal bilirubin encephalopathy were included in the study. The mean peak total serum bilirubin level was 625 μmol/L (range 480-900 μmol/L). Acoustic brainstem responses were abnormal in 73% (n = 22). Pallidal hyperintensity was observed on magnetic resonance imaging in 20 children. Peak total serum bilirubin levels correlated with motor severity (P = .03). Children with severe motor impairment were likely to manifest severe auditory neuropathy (P bilirubin-induced neurological dysfunction subtype, and the majority of children had abnormal acoustic brainstem responses and magnetic resonance imaging. © The Author(s) 2016.

  13. Regional aspects of cerebral cysticercosis. Incidence and evaluation by computerized tomography in 1000 consecutive studies

    Energy Technology Data Exchange (ETDEWEB)

    Jozzolino, D.A. (Instituto de Tomografia Axial Computadorizada de Londrina (Brazil))

    One thousand consecutive studies of the entire brain were performed and 122 patients with tomographic diagnosis of cysticercosis were found. The high incidence of this disease is discussed and its endemic characteristics as well. Various forms and types are described, the most frequent being the presence of calcifications; other tests performed at the time of computerized tomography are mentioned.

  14. Fully automatic and reference-marker-free image stitching method for full-spine and full-leg imaging with computed radiography

    Science.gov (United States)

    Wang, Xiaohui; Foos, David H.; Doran, James; Rogers, Michael K.

    2004-05-01

    Full-leg and full-spine imaging with standard computed radiography (CR) systems requires several cassettes/storage phosphor screens to be placed in a staggered arrangement and exposed simultaneously to achieve an increased imaging area. A method has been developed that can automatically and accurately stitch the acquired sub-images without relying on any external reference markers. It can detect and correct the order, orientation, and overlap arrangement of the subimages for stitching. The automatic determination of the order, orientation, and overlap arrangement of the sub-images consists of (1) constructing a hypothesis list that includes all cassette/screen arrangements, (2) refining hypotheses based on a set of rules derived from imaging physics, (3) correlating each consecutive sub-image pair in each hypothesis and establishing an overall figure-of-merit, (4) selecting the hypothesis of maximum figure-of-merit. The stitching process requires the CR reader to over scan each CR screen so that the screen edges are completely visible in the acquired sub-images. The rotational displacement and vertical displacement between two consecutive sub-images are calculated by matching the orientation and location of the screen edge in the front image and its corresponding shadow in the back image. The horizontal displacement is estimated by maximizing the correlation function between the two image sections in the overlap region. Accordingly, the two images are stitched together. This process is repeated for the newly stitched composite image and the next consecutive sub-image until a full-image composite is created. The method has been evaluated in both phantom experiments and clinical studies. The standard deviation of image misregistration is below one image pixel.

  15. Erectile Dysfunction in 101 Consecutive Hypertensive Patients and ...

    African Journals Online (AJOL)

    In a 6 month prospective questionnaire study of 101 consecutive newly referred hypertensive patients and 86 normotensive volunteers, the relationship of erectile dysfunction and hypertension in these patients was studied using a modified international index of erectile function (IIEF). The mean age of the hypertensive ...

  16. Critical analysis of consecutive unilateral cleft lip repairs: determining ideal sample size.

    Science.gov (United States)

    Power, Stephanie M; Matic, Damir B

    2013-03-01

    Objective : Cleft surgeons often show 10 consecutive lip repairs to reduce presentation bias, however the validity remains unknown. The purpose of this study is to determine the number of consecutive cases that represent average outcomes. Secondary objectives are to determine if outcomes correlate with cleft severity and to calculate interrater reliability. Design : Consecutive preoperative and 2-year postoperative photographs of the unilateral cleft lip-nose complex were randomized and evaluated by cleft surgeons. Parametric analysis was performed according to chronologic, consecutive order. The mean standard deviation over all raters enabled calculation of expected 95% confidence intervals around a mean tested for various sample sizes. Setting : Meeting of the American Cleft Palate-Craniofacial Association in 2009. Patients, Participants : Ten senior cleft surgeons evaluated 39 consecutive lip repairs. Main Outcome Measures : Preoperative severity and postoperative outcomes were evaluated using descriptive and quantitative scales. Results : Intraclass correlation coefficients for cleft severity and postoperative evaluations were 0.65 and 0.21, respectively. Outcomes did not correlate with cleft severity (P  =  .28). Calculations for 10 consecutive cases demonstrated wide 95% confidence intervals, spanning two points on both postoperative grading scales. Ninety-five percent confidence intervals narrowed within one qualitative grade (±0.30) and one point (±0.50) on the 10-point scale for 27 consecutive cases. Conclusions : Larger numbers of consecutive cases (n > 27) are increasingly representative of average results, but less practical in presentation format. Ten consecutive cases lack statistical support. Cleft surgeons showed low interrater reliability for postoperative assessments, which may reflect personal bias when evaluating another surgeon's results.

  17. Physiological and perceptual responses to three consecutive official matches in female boxer. A case study

    Directory of Open Access Journals (Sweden)

    Obmiński Zbigniew

    2014-12-01

    Full Text Available Study aim: The purpose of this study was to assess the physiological cost of three consecutive official boxing fights played during a 3-day tournament and two non-contact specific drills against handheld pads of the same time-profile as the contest, 4 × 2 minutes with 1-minute intervals between them. This assessment was based on the determination of selected hormones and metabolites in the blood sampled directly prior to the contests and throughout short-term post-contest recovery.

  18. The role of key image notes in CT imaging study interpretation.

    Science.gov (United States)

    Fan, Shu-Feng; Xu, Zhe; He, Hai-Qing; Ding, Jian-Rong; Teng, Gao-Jun

    2011-04-01

    The objective of the study was to investigate the clinical effects of CT key image notes (KIN) in the interpretation of a CT image study. All experiments were approved by the ethics committee of the local district. Six experienced radiologists were equally divided into routine reporting (RR) group and KIN reporting (KIN) group. CT scans of each 100 consecutive cases before and after using KIN technique were randomly selected, and the reports were made by group RR and KIN, respectively. All the reports were again reviewed 3 months later by both groups. All the results with using or not using KIN were interpreted and reinterpreted after 3 months by six clinicians, who were experienced in picture archiving and communication system (PACS) applications and were equally divided into the clinical routine report group and the clinical KIN report group, respectively. The results were statistically analyzed; the time used in making a report, the re-reading time 3 months later, and the consistency of imaging interpretation were determined and compared between groups. After using KIN technique, the time used in making a report was significantly increased (8.77 ± 5.27 vs. 10.53 ± 5.71 min, P < 0.05), the re-reading time was decreased (5.23 ± 2.54 vs. 4.99 ± 1.70 min, P < 0.05), the clinical interpretation and reinterpretation time after 3 months were decreased, and the consistency of the interpretation, reinterpretation between different doctors in different time was markedly improved (P < 0.01). CT report with KIN technique in PACS can significantly improve the consistency of the interpretation and efficiency in routine clinical work.

  19. Accuracy and reproducibility of tumor positioning during prolonged and multi-modality animal imaging studies

    International Nuclear Information System (INIS)

    Zhang Mutian; Huang Minming; Le, Carl; Zanzonico, Pat B; Ling, C Clifton; Koutcher, Jason A; Humm, John L; Claus, Filip; Kolbert, Katherine S; Martin, Kyle

    2008-01-01

    Dedicated small-animal imaging devices, e.g. positron emission tomography (PET), computed tomography (CT) and magnetic resonance imaging (MRI) scanners, are being increasingly used for translational molecular imaging studies. The objective of this work was to determine the positional accuracy and precision with which tumors in situ can be reliably and reproducibly imaged on dedicated small-animal imaging equipment. We designed, fabricated and tested a custom rodent cradle with a stereotactic template to facilitate registration among image sets. To quantify tumor motion during our small-animal imaging protocols, 'gold standard' multi-modality point markers were inserted into tumor masses on the hind limbs of rats. Three types of imaging examination were then performed with the animals continuously anesthetized and immobilized: (i) consecutive microPET and MR images of tumor xenografts in which the animals remained in the same scanner for 2 h duration, (ii) multi-modality imaging studies in which the animals were transported between distant imaging devices and (iii) serial microPET scans in which the animals were repositioned in the same scanner for subsequent images. Our results showed that the animal tumor moved by less than 0.2-0.3 mm over a continuous 2 h microPET or MR imaging session. The process of transporting the animal between instruments introduced additional errors of ∼0.2 mm. In serial animal imaging studies, the positioning reproducibility within ∼0.8 mm could be obtained.

  20. Increased error rates in preliminary reports issued by radiology residents working more than 10 consecutive hours overnight.

    Science.gov (United States)

    Ruutiainen, Alexander T; Durand, Daniel J; Scanlon, Mary H; Itri, Jason N

    2013-03-01

    To determine if the rate of major discrepancies between resident preliminary reports and faculty final reports increases during the final hours of consecutive 12-hour overnight call shifts. Institutional review board exemption status was obtained for this study. All overnight radiology reports interpreted by residents on-call between January 2010 and June 2010 were reviewed by board-certified faculty and categorized as major discrepancies if they contained a change in interpretation with the potential to impact patient management or outcome. Initial determination of a major discrepancy was at the discretion of individual faculty radiologists based on this general definition. Studies categorized as major discrepancies were secondarily reviewed by the residency program director (M.H.S.) to ensure consistent application of the major discrepancy designation. Multiple variables associated with each report were collected and analyzed, including the time of preliminary interpretation, time into shift study was interpreted, volume of studies interpreted during each shift, day of the week, patient location (inpatient or emergency department), block of shift (2-hour blocks for 12-hour shifts), imaging modality, patient age and gender, resident identification, and faculty identification. Univariate risk factor analysis was performed to determine the optimal data format of each variable (ie, continuous versus categorical). A multivariate logistic regression model was then constructed to account for confounding between variables and identify independent risk factors for major discrepancies. We analyzed 8062 preliminary resident reports with 79 major discrepancies (1.0%). There was a statistically significant increase in major discrepancy rate during the final 2 hours of consecutive 12-hour call shifts. Multivariate analysis confirmed that interpretation during the last 2 hours of 12-hour call shifts (odds ratio (OR) 1.94, 95% confidence interval (CI) 1.18-3.21), cross

  1. A neurophysiological study of facial numbness in multiple sclerosis: Integration with clinical data and imaging findings.

    Science.gov (United States)

    Koutsis, Georgios; Kokotis, Panagiotis; Papagianni, Aikaterini E; Evangelopoulos, Maria-Eleftheria; Kilidireas, Constantinos; Karandreas, Nikolaos

    2016-09-01

    To integrate neurophysiological findings with clinical and imaging data in a consecutive series of multiple sclerosis (MS) patients developing facial numbness during the course of an MS attack. Nine consecutive patients with MS and recent-onset facial numbness were studied clinically, imaged with routine MRI, and assessed neurophysiologically with trigeminal somatosensory evoked potential (TSEP), blink reflex (BR), masseter reflex (MR), facial nerve conduction, facial muscle and masseter EMG studies. All patients had unilateral facial hypoesthesia on examination and lesions in the ipsilateral pontine tegmentum on MRI. All patients had abnormal TSEPs upon stimulation of the affected side, excepting one that was tested following remission of numbness. BR was the second most sensitive neurophysiological method with 6/9 examinations exhibiting an abnormal R1 component. The MR was abnormal in 3/6 patients, always on the affected side. Facial conduction and EMG studies were normal in all patients but one. Facial numbness was always related to abnormal TSEPs. A concomitant R1 abnormality on BR allowed localization of the responsible pontine lesion, which closely corresponded with MRI findings. We conclude that neurophysiological assessment of MS patients with facial numbness is a sensitive tool, which complements MRI, and can improve lesion localization. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Quantitative/Statistical Approach to Bullet-to-Firearm Identification with Consecutively Manufactured Barrels

    Energy Technology Data Exchange (ETDEWEB)

    Peter Striupaitis; R.E. Gaensslen

    2005-01-30

    Efforts to use objective image comparison and bullet scanning technologies to distinguish bullets from consecutively manufactured handgun barrels from two manufacturers gave mixed results. The ability of a technology to reliably distinguish between matching and non-matching bullets, where the non-matching bullets were as close in pattern to the matching ones as is probably possible, would provide evidence that the distinctions could be made ''objectively'', and independently of human eyes. That evidence is identical or very close to what seems to be needed to satisfy Daubert standards. It is fair to say that the FTI IBIS image comparison technology correctly distinguished between all the Springfield barrel bullets, and between most but not all of the HiPoint barrel bullets. In the HiPoint cases that were not distinguished 100% of the time, they would he distinguished correctly at least 83% of the time. These results, although obviously limited to the materials used in the comparisons, provide strong evidence that barrel-to-bullet matching is objectively reliable. The results with SciClops were less compelling. The results do not mean that bullet-to-barrel matching is not objectively reliable--rather, they mean that this version of the particular technology could not quite distinguish between these extremely similar yet different bullets as well as the image comparison technology did. In a number of cases, the numerical results made the correct distinctions, although they were close to one another. It is hard to say from this data that this technology differs in its ability to make distinctions between the manufacturers, because the results are very similar with both. The human examiner results were as expected. We did not expect any misidentifications, and there were not any. It would have been preferable to have a higher return rate, and thus more comparisons in the overall sample. As noted, the ''consecutively manufactured barrel

  3. Detection of brain metastasis. Comparison of Turbo-FLAIR imaging, T2-weighted imaging and double-dose gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Okubo, Toshiyuki; Hayashi, Naoto; Shirouzu, Ichiro; Abe, Osamu; Ohtomo, Kuni; Sasaki, Yasuhito; Aoki, Shigeki; Wada, Akihiko

    1998-01-01

    The purpose of this study was to compare Turbo-FLAIR imaging, T 2 -weighted imaging, and double-dose gadolinium-enhanced MR imaging in the detection of brain metastasis. Using the three sequences, 20 consecutive patients with brain metastases were prospectively studied with a 1.5-Tesla system. Three independent, blinded readers assessed the images for the presence, size, number, and location of metastatic lesions. In the detection of large lesions (>0.5 cm), Turbo-FLAIR imaging (38/48, 79%) was not significantly different from gadolinium-enhanced imaging (42/48, 88%) (p=0.273). T 2 -weighted imaging (31/48, 65%), however, was inferior to gadolinium-enhanced imaging (p<0.05). There was no difference between Turbo-FLAIR imaging and gadolinium-enhanced imaging in the accuracy of detecting solitary brain metastasis (4/4, 100%). In conclusion, Turbo-FLAIR imaging is a useful, noninvasive screening modality for brain metastasis. Its use may lead to cost savings in the diagnosis of brain metastases and may impact positively the cost-effectiveness of treatment. (author)

  4. Reliability evaluation of linear multi-state consecutively-connected systems constrained by m consecutive and n total gaps

    International Nuclear Information System (INIS)

    Yu, Huan; Yang, Jun; Peng, Rui; Zhao, Yu

    2016-01-01

    This paper extends the linear multi-state consecutively-connected system (LMCCS) to the case of LMCCS-MN, where MN denotes the dual constraints of m consecutive gaps and n total gaps. All the nodes are distributed along a line and form a sequence. The distances between the adjacent nodes are usually non-uniform. The nodes except the last one can contain statistically independent multi-state connection elements (MCEs). Each MCE can provide a connection between the node at which it is located and the next nodes along the sequence. The LMCCS-MN fails if it meets either of the two constraints. The universal generating function technique is adopted to evaluate the system reliability. The optimal allocations of LMCCS-MN with two different types of failures are solved by genetic algorithm. Finally, two examples are given for the demonstration of the proposed model. - Highlights: • A new model of multi-state consecutively-connected system (LMCCS-MN) is proposed. • The non-uniform distributed nodes are involved in the proposed LMCCS-MN model. • An algorithm for system reliability evaluation is provided by the UGF method. • The computational complexity of the proposed algorithm is discussed in detail. • Optimal element allocation problem is formulated and solved.

  5. Consecutive dynamic resolutions of phosphine oxides

    NARCIS (Netherlands)

    Kortmann, Felix A.; Chang, Mu-Chieh; Otten, Edwin; Couzijn, Erik P. A.; Lutz, Martin; Minnaard, Adriaan J.

    2013-01-01

    A crystallization-induced asymmetric transformation (CIAT) involving a radical-mediated racemization provides access to enantiopure secondary phosphine oxides. A consecutive CIAT is used to prepare enantio-and diastereo-pure tert-butyl(hydroxyalkyl)phenylphosphine oxides.

  6. Multimodal ultrasound tomography for breast imaging: a prospective study of clinical feasibility.

    Science.gov (United States)

    Forte, S; Dellas, S; Stieltjes, B; Bongartz, B

    2017-01-01

    To describe the clinical set-up and evaluate the feasibility of multimodal ultrasound tomography (MUT) for breast imaging. Thirty-two consecutive patients referred for breast imaging and 24 healthy volunteers underwent MUT. In the 32 patients, the examination discomfort was compared to that of mammography (n = 31), handheld ultrasound (HUS) (n = 27) and magnetic resonance imaging (MRI) (n = 4) on a scale from 1 (lowest discomfort) to 10 (highest discomfort). MUT investigation time was recorded. Findings automatically detected by MUT were correlated with conventional imaging and biopsy results. Breast MUT was well tolerated by all 56 participants; 55 bilateral exams were uneventful. During one exam, the digitalisation card failed and the exam was successfully repeated within three days. Mean examination discomfort was 1.6 (range = 1-5) for MUT, 1.5 (range = 1-5) for HUS, 5.3 (range = 3-7) for MRI, and 6.3 (range = 1-10) for mammography. MUT examination time was 38 ± 6 min (mean ± standard deviation). In the patients referred for breast imaging, MUT detected four lesions and indicated malignancy in three of these cases. These findings were confirmed by additional imaging and biopsy. MUT is feasible in a clinical context considering examination time and patient acceptance. These interesting initial diagnostic findings warrant further studies.

  7. Prognostic value of high-dose dobutamine stress magnetic resonance imaging in 1,493 consecutive patients: assessment of myocardial wall motion and perfusion.

    Science.gov (United States)

    Korosoglou, Grigorios; Elhmidi, Yacine; Steen, Henning; Schellberg, Dieter; Riedle, Nina; Ahrens, Johannes; Lehrke, Stephanie; Merten, Constanze; Lossnitzer, Dirk; Radeleff, Jannis; Zugck, Christian; Giannitsis, Evangelos; Katus, Hugo A

    2010-10-05

    This study sought to determine the prognostic value of wall motion and perfusion assessment during high-dose dobutamine stress (DS) cardiac magnetic resonance imaging (MRI) in a large patient cohort. DS-MRI offers the possibility to integrate myocardial perfusion and wall motion analysis in a single examination for the detection of coronary artery disease (CAD). A total of 1,493 consecutive patients with suspected or known CAD underwent DS-MRI, using a standard protocol in a 1.5-T magnetic resonance scanner. Wall motion and perfusion were assessed at baseline and during stress, and outcome data including cardiac death, nonfatal myocardial infarction ("hard events"), and "late" revascularization performed >90 days after the MR scans were collected during a 2 ± 1 year follow-up period. Fifty-three hard events, including 14 cardiac deaths and 39 nonfatal infarctions, occurred during the follow-up period, whereas 85 patients underwent "late" revascularization. Using multivariable regression analysis, an abnormal result for wall motion or perfusion during stress yielded the strongest independent prognostic value for both hard events and late revascularization, clearly surpassing that of clinical and baseline magnetic resonance parameters (for wall motion: adjusted hazard ratio [HR] of 5.9 [95% confidence interval (CI): 2.5 to 13.6] for hard events and of 3.1 [95% CI: 1.7 to 5.6] for late revascularization, and for perfusion: adjusted HR of 5.4 [95% CI: 2.3 to 12.9] for hard events and of 6.2 [95% CI: 3.3 to 11.3] for late revascularization, p < 0.001 for all). DS-MRI can accurately identify patients who are at increased risk for cardiac death and myocardial infarction, separating them from those with normal findings, who have very low risk for future cardiac events. (Prognostic Value of High Dose Dobutamine Stress Magnetic Resonance Imaging; NCT00837005). Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. The role of dynamic susceptibility contrast-enhanced perfusion MR imaging in differentiating between infectious and neoplastic focal brain lesions: results from a cohort of 100 consecutive patients.

    Directory of Open Access Journals (Sweden)

    Valdeci Hélio Floriano

    Full Text Available BACKGROUND AND PURPOSE: Differentiating between infectious and neoplastic focal brain lesions that are detected by conventional structural magnetic resonance imaging (MRI may be a challenge in routine practice. Brain perfusion-weighted MRI (PWI may be employed as a complementary non-invasive tool, providing relevant data on hemodynamic parameters, such as the degree of angiogenesis of lesions. We aimed to employ dynamic susceptibility contrast-enhanced perfusion MR imaging (DSC-MRI to differentiate between infectious and neoplastic brain lesions by investigating brain microcirculation changes. MATERIALS AND METHODS: DSC-MRI perfusion studies of one hundred consecutive patients with non-cortical neoplastic (n = 54 and infectious (n = 46 lesions were retrospectively assessed. MRI examinations were performed using a 1.5-T scanner. A preload of paramagnetic contrast agent (gadolinium was administered 30 seconds before acquisition of dynamic images, followed by a standard dose 10 seconds after starting imaging acquisitions. The relative cerebral blood volume (rCBV values were determined by calculating the regional cerebral blood volume in the solid areas of lesions, normalized to that of the contralateral normal-appearing white matter. Discriminant analyses were performed to determine the cutoff point of rCBV values that would allow the differentiation of neoplastic from infectious lesions and to assess the corresponding diagnostic performance of rCBV when using this cutoff value. RESULTS: Neoplastic lesions had higher rCBV values (4.28±2.11 than infectious lesions (0.63±0.49 (p<0.001. When using an rCBV value <1.3 as the parameter to define infectious lesions, the sensitivity of the method was 97.8% and the specificity was 92.6%, with a positive predictive value of 91.8%, a negative predictive value of 98.0%, and an accuracy of 95.0%. CONCLUSION: PWI is a useful complementary tool in distinguishing between infectious and neoplastic brain

  9. Analyte variations in consecutive 24-hour urine collections in children.

    Science.gov (United States)

    Ellison, Jonathan S; Hollingsworth, John M; Langman, Craig B; Asplin, John R; Schwaderer, Andrew L; Yan, Phyllis; Bierlein, Maggie; Barraza, Mark A; Defoor, William R; Figueroa, T Ernesto; Jackson, Elizabeth C; Jayanthi, Venkata R; Johnson, Emilie K; Joseph, David B; Shnorhavorian, Margarett

    2017-12-01

    The metabolic evaluation of children with nephrolithiasis begins with a 24-h urine collection. For adults, the diagnostic yield increases with consecutive collections; however, little is known regarding the variability of multiple 24-h studies in the pediatric population. We sought to evaluate the variability of consecutive 24-h urine collection in children through a multi-institutional study hypothesizing that compared with a single collection, consecutive 24-h urine collections would reveal a greater degree of clinically useful information in the evaluation of children at risk for nephrolithiasis. Including data from six institutions, we identified children less than 18 years of age considered at risk for recurrent nephrolithiasis, undergoing metabolic evaluation. We evaluated a subset of patients performing two collections with urine creatinine varying by 10% or less during a 7-day period. Discordance between repeat collections based on normative urine chemistry values was evaluated. A total of 733 children met inclusion criteria, and in over a third both urine calcium and urine volume differed by 30% or more between samples. Urine oxalate demonstrated greater variation between collections in children collections prior to targeted intervention to modify stone risk are advised to increase diagnostic yield in children at risk for nephrolithiasis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  10. Consecutive dynamic resolutions of phosphine oxides

    NARCIS (Netherlands)

    Kortmann, Felix A.; Chang, Mu Chieh; Otten, Edwin; Couzijn, Erik P A; Lutz, Martin|info:eu-repo/dai/nl/304828971; Minnaard, Adriaan J.

    2014-01-01

    A crystallization-induced asymmetric transformation (CIAT) involving a radical-mediated racemization provides access to enantiopure secondary phosphine oxides. A consecutive CIAT is used to prepare enantio- and diastereo-pure tert-butyl(hydroxyalkyl)phenylphosphine oxides. © 2014 The Royal Society

  11. Acute effects of heavy-load squats on consecutive squat jump performance.

    Science.gov (United States)

    Weber, Kurt R; Brown, Lee E; Coburn, Jared W; Zinder, Steven M

    2008-05-01

    Postactivation potentiation (PAP) and complex training have generated interest within the strength and conditioning community in recent years, but much of the research to date has produced confounding results. The purpose of this study was to observe the acute effects of a heavy-load back squat [85% 1 repetition maximum (1RM)] condition on consecutive squat jump performance. Twelve in-season Division I male track-and-field athletes participated in two randomized testing conditions: a five-repetition back squat at 85% 1RM (BS) and a five-repetition squat jump (SJ). The BS condition consisted of seven consecutive squat jumps (BS-PRE), followed by five repetitions of the BS at 85% 1RM, followed by another set of seven consecutive squat jumps (BS-POST). The SJ condition was exactly the same as the BS condition except that five consecutive SJs replaced the five BSs, with 3 minutes' rest between each set. BS-PRE, BS-POST, SJ-PRE, and SJ-POST were analyzed and compared for mean and peak jump height, as well as mean and peak ground reaction force (GRF). The BS condition's mean and peak jump height and peak GRF increased 5.8% +/- 4.8%, 4.7% +/- 4.8%, and 4.6% +/- 7.4%, respectively, whereas the SJ condition's mean and peak jump height and peak GRF decreased 2.7% +/- 5.0%, 4.0% +/- 4.9%, and 1.3% +/- 7.5%, respectively. The results indicate that performing a heavy-load back squat before a set of consecutive SJs may enhance acute performance in average and peak jump height, as well as peak GRF.

  12. Factors predisposing to consecutive esotropia after surgery to correct intermittent exotropia.

    Science.gov (United States)

    Jang, Jung Hyun; Park, Jung Min; Lee, Soo Jung

    2012-10-01

    To investigate the incidence of and factors predisposing to consecutive esotropia after intermittent exotropia surgery, and to prevent the onset of consecutive esotropia. We retrospectively surveyed 226 patients who had been followed up for more than 1 year after surgery for intermittent exotropia conducted between February 2005 and September 2010. Consecutive esotropia was defined as an esotropia of at least 10 prism diopters (PD) at distance or near at least once in 2 weeks after surgery. Presumed risk factors for consecutive esotropia were analyzed. Gender, age at surgery, average binocular spherical equivalent, anisometropia, high myopia, amblyopia, preoperative angle of deviation, vertical deviation, A-V pattern strabismus, exotropia type, type of surgery, stereopsis, and suppression were investigated to evaluate factors influencing the onset of consecutive esotropia. Consecutive esotropia occurred in 22 patients (9.7 %). Significant correlations with occurrence of the condition were found with high myopia (P = 0.013), amblyopia (P = 0.047), preoperative angle of deviation of 25-40 PD at distance (P = 0.016), deviation at distance - deviation at near > 10 PD (P = 0.041), lateral incomitance (P = 0.007), tenacious proximal convergence fusion type (P = 0.001), unilateral lateral rectus muscle recession and medial rectus muscle resection (P = 0.001). High myopia, amblyopia, and lateral incomitance were predisposing factors for consecutive esotropia. Furthermore, the preoperative angle of deviation at distance, differences between the angle of deviation at near and at distance, the type of intermittent exotropia, and the type of surgery affected the incidence of consecutive esotropia. More attention must be paid to patients with such factors.

  13. Efficiency of Medial Rectus Advancement Surgery in Consecutive Exotropia

    Directory of Open Access Journals (Sweden)

    Kemal Yar

    2015-12-01

    Full Text Available Purpose: To evaluate the efficiency of medial rectus advancement surgery in consecutive exotropia. Material and Methods: The study group consisted of 20 cases, 10 male, 10 female, who were diagnosed as consecutive exotropia and underwent surgery between 2008-2013 at Cukurova University Medical Faculty Ophthalmology Department. Records of the patients were investigated retrospectively. We evaluated best corrected visual acuity, existence of ambliopia, postoperative duration following the first surgery and applied surgical procedures. Postoperative deviation lower than 10 PD were assesed as successful. Mean follow up period was 29,8 +/- 21,36 (8-80 months, patients with inadequate follow up period were dismissed from the study group. Results: We only applied bilateral medial rectus advancement surgery to 6 and unilateral medial rectus advancement surgery to 5 patients and obtained intended surgical result in these 11 cases. The other patients underwent lateral rectus recession or/and medial rectus resection operations inorder to reach projected deviation degrees. Deviation was found to be 46,4+/-9,24 (40-70 PD in cases who only underwent advancement surgery and was 65,56 +/- 18,78 (40-90 PD in cases who underwent additional surgical procedure. 16 (%80 of the cases had hypermetropi various dioptries and 7 (%35 had ambliopia. Discussion: Consecutive exotropia can appear years after surgery and is an important late period complication. In this study achievement of %55 success with medial rectus advancement surgery indicates that this is a preferable procedure. But in wide angle deviations additional lateral rectus recession or/and medial rectus resection operations can be applied inorder to reach intended adjustment. Accurrate prediction of the propotion of advancement surgery and adjustment is not always possible because of intensive fybrosis in operated muscles and enviroment tissue. [Cukurova Med J 2015; 40(4.000: 707-713

  14. Caffeine and performance over consecutive days of simulated competition.

    Science.gov (United States)

    Stadheim, Hans Kristian; Spencer, Matthew; Olsen, Raymond; Jensen, Jørgen

    2014-09-01

    Performance improvements after caffeine (CAF) ingestion are well documented when using a 1-d protocol. In numerous competitions such as the Tour de France, Tour de Ski, world championships, and National College Athletic Association championships, athletes compete for several days in a row. To date, no studies have investigated the effects of CAF when competing for consecutive days in a row. This study aimed to investigate the effects of placebo (PLA) and two different CAF doses (3 and 4.5 mg·kg body mass) on performance in a 10-min all-out, cross-country, double poling ergometer test (C-PT) 2 d in a row. Eight highly trained male cross-country skiers (V˙O2max-run, 78.5 ± 1.6 mL·kg·min) participated in the study, which was a randomized, double-blind, PLA-controlled, crossover design. Performance was assessed as distance covered during a 10-min all-out C-PT. Oral ingestion of CAF or PLA was consumed 75 min before the all-out C-PT. Poling distance was improved after CAF ingestions compared with that after PLA on both days. The improvements on day 1 were 4.0% (90% confidence limits, ±3.3) and 4.0% ± 2.9% for both CAF doses, respectively (P performance was associated with increased HR, adrenaline concentration, blood lactate concentration, and V˙O2 consumption after CAF ingestion. Furthermore, performance was elevated despite higher creatine kinase concentration and muscular pain at arrival on day 2 for both CAF doses. Both CAF doses improved performance in the 10-min all-out C-PT compared with PLA over two consecutive days. Therefore, CAF seems useful for athletes competing over consecutive days despite higher muscle damage occurring after enhanced performance on the first day.

  15. Automatic lameness detection based on consecutive 3D-video recordings

    NARCIS (Netherlands)

    Hertem, van T.; Viazzi, S.; Steensels, M.; Maltz, E.; Antler, A.; Alchanatis, V.; Schlageter-Tello, A.; Lokhorst, C.; Romanini, C.E.B.; Bahr, C.; Berckmans, D.; Halachmi, I.

    2014-01-01

    Manual locomotion scoring for lameness detection is a time-consuming and subjective procedure. Therefore, the objective of this study is to optimise the classification output of a computer vision based algorithm for automated lameness scoring. Cow gait recordings were made during four consecutive

  16. Comparative evaluation of RetCam vs. gonioscopy images in congenital glaucoma

    OpenAIRE

    Azad, Raj V; Chandra, Parijat; Chandra, Anuradha; Gupta, Aparna; Gupta, Viney; Sihota, Ramanjit

    2014-01-01

    Purpose: To compare clarity, exposure and quality of anterior chamber angle visualization in congenital glaucoma patients, using RetCam and indirect gonioscopy images. Design: Cross-sectional study Participants. Congenital glaucoma patients over age of 5 years. Materials and Methods: A prospective consecutive pilot study was done in congenital glaucoma patients who were older than 5 years. Methods used are indirect gonioscopy and RetCam imaging. Clarity of the image, extent of angle visible a...

  17. The effect of the number of consecutive night shifts on diurnal rhythms in cortisol, melatonin and heart rate variability (HRV)

    DEFF Research Database (Denmark)

    Jensen, Marie Aarrebo; Garde, Anne Helene; Kristiansen, Jesper

    2016-01-01

    PURPOSE: The purpose of this review is to summarize the current knowledge from field studies on how many consecutive night shifts are required for adaptation of diurnal rhythms in cortisol, melatonin and heart rate variability (HRV) to night work. METHODS: A systematic search of the databases Pub...... recordings for HRV. Most of the studies in the review were small studies with less than 30 participants, and most studies evaluated diurnal rhythms after only two consecutive night shifts whereas only six studies used seven or more consecutive night shifts. The majority of studies found that adaptation...... to night work had not occurred after two consecutive night shifts, whereas a small number found evidence for full adaptation after seven consecutive night shifts based on diurnal rhythms in cortisol and melatonin. CONCLUSION: There are methodological differences in the field studies analyzing diurnal...

  18. Aspiration-related deaths in 57 consecutive patients: autopsy study.

    Directory of Open Access Journals (Sweden)

    Xiaowen Hu

    Full Text Available Aspiration can cause a diverse spectrum of pulmonary disorders some of which can lead to death but can be difficult to diagnose.The medical records and autopsy findings of 57 consecutive patients in whom aspiration was the immediate cause of death at Mayo Clinic (Rochester, MN, USA over a 9-yr period, from January 1 2004 to December 31 2012 were analyzed.The median age at death was 72 years (range, 13-95 years and included 39 (68% males. The most common symptom before death was dyspnea (63% and chest radiography revealed bilateral infiltrates in the majority (81%. Most common precipitating factors for aspiration were depressed consciousness (46% and dysphagia (44%. Aspiration-related syndromes leading to death were aspiration pneumonia in 26 (46%, aspiration pneumonitis in 25 (44%, and large airway obstruction in 6 patients (11%. Aspiration was clinically unsuspected in 19 (33% patients. Antimicrobial therapy had been empirically administered to most patients (90% with aspiration pneumonia and aspiration pneumonitis.We conclude aspiration-related deaths occur most commonly in the elderly with identifiable risks and presenting bilateral pulmonary infiltrates. One-third of these aspiration-related pulmonary syndromes were clinically unsuspected at the time of death.

  19. The role of cognitive representation in consecutive interpretation: a case study

    Directory of Open Access Journals (Sweden)

    Daniela Corina Ionescu

    2008-01-01

    Full Text Available A long-standing source of conceptual difficulty and confusion in interpretation has been the overall construal of the world in the interpreter’s mind when listening to the source language speech. Hence, the target language rendition can be dramatically marked by lack of understanding or by conceptual misrepresentations. The present paper deals with possible landmarks in the follow-up of the target renditions, on the basis of research conducted in the European Master’s Programme for Interpreters’ training in the University of Bucharest. Ultimately, it is not only knowledge of the world and knowledge of the topic that determines appropriate comprehension, it is also knowledge of language grammar that can decisively contribute to a correct, fluent and reliable message in consecutive interpretation.

  20. Magnetic resonance imaging of the visual pathway - anatomical and technical considerations

    International Nuclear Information System (INIS)

    Sosnowski, P.; Paprzycki, W.

    1993-01-01

    Magnetic resonance tomography creates possibility of imaging the whole visual pathway and is superior to CT. Plenitude of MR techniques can sometimes be the reason of unnecessary prolongation of the examination. This study tries to evaluate usefulness of different MR techniques and planes for optimal imaging of consecutive sections of visual pathway. (author)

  1. Reducing radiation dose without compromising image quality in preoperative perforator flap imaging with CTA using ASIR technology.

    Science.gov (United States)

    Niumsawatt, Vachara; Debrotwir, Andrew N; Rozen, Warren Matthew

    2014-01-01

    Computed tomographic angiography (CTA) has become a mainstay in preoperative perforator flap planning in the modern era of reconstructive surgery. However, the increased use of CTA does raise the concern of radiation exposure to patients. Several techniques have been developed to decrease radiation dosage without compromising image quality, with varying results. The most recent advance is in the improvement of image reconstruction using an adaptive statistical iterative reconstruction (ASIR) algorithm. We sought to evaluate the image quality of ASIR in preoperative deep inferior epigastric perforator (DIEP) flap surgery, through a direct comparison with conventional filtered back projection (FBP) images. A prospective review of 60 consecutive ASIR and 60 consecutive FBP CTA images using similar protocol (except for radiation dosage) was undertaken, analyzed by 2 independent reviewers. In both groups, we were able to accurately identify axial arteries and their perforators. Subjective analysis of image quality demonstrated no statistically significant difference between techniques. ASIR can thus be used for preoperative imaging with similar image quality to FBP, but with a 60% reduction in radiation delivery to patients.

  2. Reaction Times to Consecutive Automation Failures: A Function of Working Memory and Sustained Attention.

    Science.gov (United States)

    Jipp, Meike

    2016-12-01

    This study explored whether working memory and sustained attention influence cognitive lock-up, which is a delay in the response to consecutive automation failures. Previous research has demonstrated that the information that automation provides about failures and the time pressure that is associated with a task influence cognitive lock-up. Previous research has also demonstrated considerable variability in cognitive lock-up between participants. This is why individual differences might influence cognitive lock-up. The present study tested whether working memory-including flexibility in executive functioning-and sustained attention might be crucial in this regard. Eighty-five participants were asked to monitor automated aircraft functions. The experimental manipulation consisted of whether or not an initial automation failure was followed by a consecutive failure. Reaction times to the failures were recorded. Participants' working-memory and sustained-attention abilities were assessed with standardized tests. As expected, participants' reactions to consecutive failures were slower than their reactions to initial failures. In addition, working-memory and sustained-attention abilities enhanced the speed with which participants reacted to failures, more so with regard to consecutive than to initial failures. The findings highlight that operators with better working memory and sustained attention have small advantages when initial failures occur, but their advantages increase across consecutive failures. The results stress the need to consider personnel selection strategies to mitigate cognitive lock-up in general and training procedures to enhance the performance of low ability operators. © 2016, Human Factors and Ergonomics Society.

  3. Injury incidence in a Spanish sub-elite professional football team: A prospective study during four consecutive seasons

    OpenAIRE

    Mallo Sainz, Javier; González Frutos, Pablo; Veiga Fernandez, Santiago; Navarro Cabello, Enrique

    2011-01-01

    The aim of this study was to investigate the injury incidence and injury characteristics of a Spanish sub-elite professional football team during four consecutive seasons. A team was followed prospectively from the season 2003-2004 to 2006-2007 and individual player exposure and time loss injuries were recorded during all club training sessions and matches. A total of 313 time-loss injuries were recorded. The mean injury incidence was 10.9 injuries/1000 hours (5.2 injuries/1000 training hours...

  4. Endoscopic-Assisted Surgery for Pyriform Sinus Fistula in Chinese Children: A 73-Consecutive-Case Study.

    Science.gov (United States)

    Sheng, Qingfeng; Lv, Zhibao; Xiao, Xianmin; Xu, Weijue; Liu, Jiangbin; Wu, Yibo

    2016-01-01

    Complete resection of the pyriform sinus fistula (PSF) tract is challenging due to repeated infection and inadequate procedures. We present our experiences with intraoperative endoscopic-assisted intubation or instillation of dye through the internal opening as a guide to identify the tract. We retrospectively reviewed the charts of 73 consecutive patients diagnosed with PSF during 1999 until 2014 from two tertiary referral centers. Demographics, clinical presentation, imaging, treatment, and outcome were analyzed. The intraoperative endoscopy was successfully conducted in all 73 cases. No gender predominance was observed. Of the anomalies, 94.5% were left-sided. Presenting symptoms consisted of neck abscess (n = 48), acute suppurative thyroiditis/thyroid abscess (n = 9), neck mass with or without dyspnea (n = 12), and thyroid nodule (n = 4). Barium esophagography and computed tomography scan with oral or intravenous contrast had a satisfactory positive predictive value. Partial thyroidectomy was performed on 25 cases (34.2%) if the ipsilateral thyroid was involved. Good outcome was achieved in all but 3 patients (70/73, 95.9%) during a median follow-up of 4 years (range, 8 months-14 years). Two patients developed postoperative complications: temporary vocal fold motion impairment and left-sided Horner's syndrome, respectively. PSF recurred in 1 case. A complete resection is essential for good outcomes. Intraoperative intubation or methylene blue injection by endoscopy can simplify the identification of the fistula tract during surgical exploration.

  5. Potential Measurement Errors Due to Image Enlargement in Optical Coherence Tomography Imaging

    Science.gov (United States)

    Uji, Akihito; Murakami, Tomoaki; Muraoka, Yuki; Hosoda, Yoshikatsu; Yoshitake, Shin; Dodo, Yoko; Arichika, Shigeta; Yoshimura, Nagahisa

    2015-01-01

    The effect of interpolation and super-resolution (SR) algorithms on quantitative and qualitative assessments of enlarged optical coherence tomography (OCT) images was investigated in this report. Spectral-domain OCT images from 30 eyes in 30 consecutive patients with diabetic macular edema (DME) and 20 healthy eyes in 20 consecutive volunteers were analyzed. Original image (OR) resolution was reduced by a factor of four. Images were then magnified by a factor of four with and without application of one of the following algorithms: bilinear (BL), bicubic (BC), Lanczos3 (LA), and SR. Differences in peak signal-to-noise ratio (PSNR), retinal nerve fiber layer (RNFL) thickness, photoreceptor layer status, and parallelism (reflects the complexity of photoreceptor layer alterations) were analyzed in each image type. The order of PSNRs from highest to lowest was SR > LA > BC > BL > non-processed enlarged images (NONE). The PSNR was statistically different in all groups. The NONE, BC, and LA images resulted in significantly thicker RNFL measurements than the OR image. In eyes with DME, the photoreceptor layer, which was hardly identifiable in NONE images, became detectable with algorithm application. However, OCT photoreceptor parameters were still assessed as more undetectable than in OR images. Parallelism was not statistically different in OR and NONE images, but other image groups had significantly higher parallelism than OR images. Our results indicated that interpolation and SR algorithms increased OCT image resolution. However, qualitative and quantitative assessments were influenced by algorithm use. Additionally, each algorithm affected the assessments differently. PMID:26024236

  6. MR imaging of tuberculous vertebral osteomyelitis: pictorial review

    Energy Technology Data Exchange (ETDEWEB)

    Gouliamos, A.D.; Kehagias, D.T.; Lahanis, S.; Moulopoulou, E.S.; Kalovidouris, A.A.; Trakadas, S.J.; Vlahos, L.j. [Dept. of Radiology, University of Athens (Greece); Athanassopoulou, A.A. [Dept. of Radiology, Asklipiion Hospital, Athens (Greece)

    2001-04-01

    Vertebral osteomyelitis is one of the most common manifestations of tuberculosis. Magnetic resonance imaging is considered the main imaging modality for the diagnosis, the demonstration of the extent of the disease, and follow-up studies. Vertebral destruction involving two consecutive levels with sparing of the intervertebral disc, disc herniation into the vertebral body, epidural involvement, and paraspinal abscess are the most common MRI findings suggestive of tuberculous vertebral osteomyelitis. (orig.)

  7. Consecutive cycles of hospital accreditation

    DEFF Research Database (Denmark)

    Falstie-Jensen, Anne Mette; Bogh, Søren Bie; Johnsen, Søren Paaske

    2018-01-01

    Objective: To examine the association between compliance with consecutive cycles of accreditation and patient-related outcomes. Design: A Danish nationwide population-based study from 2012 to 2015. Setting: In-patients admitted with one of the 80 diagnoses at public, non-psychiatric hospitals....... Participants: In-patients admitted with one of 80 primary diagnoses which accounted for 80% of all deaths occuring within 30 dyas after admission. Intervention: Admission to a hospital with high (n = 125 485 in-patients) or low compliance (n = 152 074 in-patients) in both cycles of accreditation by the Danish...... admission (adjusted OR: 1.26 (95% CI: 1.11-1.43) and a longer LOS (adjusted HR of discharge: 0.89 (95% CI: 0.82-0.95) than in-patients at high compliant hospitals. No difference was seen for acute readmission (adjusted HR: 0.98 (95% CI: 0.90-1.06)). Focusing on the second cycle alone, in...

  8. Mediating Peer Teaching for Learning Games: An Action Research Intervention across Three Consecutive Sport Education Seasons

    Science.gov (United States)

    Farias, Cláudio; Mesquita, Isabel; Hastie, Peter A.; O'Donovan, Toni

    2018-01-01

    Purpose: The purpose of this study was to provide an integrated analysis of a teacher's peer-teaching mediation strategies, the student-coaches' instruction, and the students' gameplay development across 3 consecutive seasons of sport education. Method: Twenty-six 7th-grade students participated in 3 consecutive sport education seasons of invasion…

  9. Algorithm-Architecture Matching for Signal and Image Processing

    CERN Document Server

    Gogniat, Guy; Morawiec, Adam; Erdogan, Ahmet

    2011-01-01

    Advances in signal and image processing together with increasing computing power are bringing mobile technology closer to applications in a variety of domains like automotive, health, telecommunication, multimedia, entertainment and many others. The development of these leading applications, involving a large diversity of algorithms (e.g. signal, image, video, 3D, communication, cryptography) is classically divided into three consecutive steps: a theoretical study of the algorithms, a study of the target architecture, and finally the implementation. Such a linear design flow is reaching its li

  10. Can independent coronal multiplanar reformatted images obtained using state-of-the-art MDCT scanners be used for primary interpretation of MDCT of the abdomen and pelvis? A feasibility study

    International Nuclear Information System (INIS)

    Sebastian, Sunit; Kalra, Mannudeep K.; Mittal, Pardeep; Saini, Sanjay; Small, William C.

    2007-01-01

    Purpose: To evaluate if coronal reformatted images can be used for primary interpretation of MDCT of the abdomen and pelvis using 64-slice MDCT. Materials and methods: IRB approval was obtained. We reviewed MDCT studies of the abdomen and pelvis of 220 consecutive patients performed with 64 row MDCT with constant scanning parameters. Based on a 0.625 mm raw data set, transverse images were reconstructed at 5 mm and coronal images at 3 mm using standard reconstruction algorithms. Reader familiarity was achieved by simultaneous evaluation of transverse and coronal reformats in an initial group of 20 separate cases for findings in consensus. Two subsequent phases of image analysis were then performed in two groups of 100 patients each. In the first phase two radiologists evaluated the added utility of simultaneous review of MDCT of transverse and coronal reformatted images over transverse images alone in 100 consecutive patients referred for MDCT of the abdomen and pelvis. In the second phase, the same radiologists evaluated whether coronal multiplanar reformats could be used for primary interpretation of MDCT of the abdomen and pelvis in a separate but similar cohort of 100 consecutive abdominopelvic MDCT studies. The number of lesion(s), their location, size of smallest lesion, presence of artifacts and likely diagnosis were noted at each image interpretation. Image quality and confidence for interpretation was evaluated using five-point and three-point scale, respectively. The time required for primary interpretation of coronal reformats and transverse images were recorded. Statistical analysis was performed using Wilcoxon signed rank test. Results: Both readers detected additional findings (n = 37, 35), respectively, on simultaneous review of transverse and coronal reformats as compared with transverse images alone (p < 0.001). Excellent interobserver agreement was noted (r = 0.94-0.96). Both readers detected additional findings (n = 62, 53), respectively, on

  11. Prevalence of Congenital Coronary Artery Anomalies and Variants in 2697 Consecutive Patients Using 64-Detector Row Coronary CTAngiography

    International Nuclear Information System (INIS)

    Shabestari, Abbas Arjmand; Akhlaghpoor, Shahram; Tayebivaljozi, Reza; Fattahi Masrour, Farzaneh

    2012-01-01

    Coronary artery anomalies are not common, but could be very serious. This study determines the frequency of coronary anomalies and normal variants by multi-detector-row computed tomography (MDCT). The results of cardiac MDCT study in 2697 consecutive patients were analyzed retrospectively. Acquisition was performed by a 64-detector row CT machine. Imaging results were assessed by experienced radiologists. Myocardial bridging was by far the most frequent coronary variant (n = 576, 21.3%). Eighty-three subjects (3.1%) showed other coronary anomalies and variants. Anomalies of origination and course of the left main coronary artery (LMCA) were detected in 1.09% of the subjects. The frequency of these anomalies in the right coronary artery (RCA), left circumflex artery (LCx), left anterior descending artery (LAD), posterior descending artery (PDA) and obtuse marginal (OM) artery were 1.24%, 0.33%, 0.1%, 0.07% and 0.03%, respectively. The single coronary pattern was seen in 0.18% and coronary fistulas in 0.07%. Based on the fact that coronary CT-angiography using MDCT can display different coronary anomalies, this study shows similar results to other reports on the subject. Future advances in the performance of CT machines will further improve the quality of CT-based cardiac imaging

  12. Reducing Radiation Dose in Coronary Angiography and Angioplasty Using Image Noise Reduction Technology.

    Science.gov (United States)

    Kastrati, Mirlind; Langenbrink, Lukas; Piatkowski, Michal; Michaelsen, Jochen; Reimann, Doris; Hoffmann, Rainer

    2016-08-01

    This study sought to quantitatively evaluate the reduction of radiation dose in coronary angiography and angioplasty with the use of image noise reduction technology in a routine clinical setting. Radiation dose data from consecutive 605 coronary procedures (397 consecutive coronary angiograms and 208 consecutive coronary interventions) performed from October 2014 to April 2015 on a coronary angiography system with noise reduction technology (Allura Clarity IQ) were collected. For comparison, radiation dose data from consecutive 695 coronary procedures (435 coronary angiograms and 260 coronary interventions) performed on a conventional coronary angiography system from October 2013 to April 2014 were evaluated. Patient radiation dosage was evaluated based on the cumulative dose area product. Operators and operator practice did not change between the 2 evaluated periods. Patient characteristics were collected to evaluate similarity of patient groups. Image quality was evaluated on a 5-grade scale in 30 patients of each group. There were no significant differences between the 2 evaluated groups in gender, age, weight, and fluoroscopy time (6.8 ± 6.1 vs 6.9 ± 6.3 minutes, not significant). The dose area product was reduced from 3195 ± 2359 to 983 ± 972 cGycm(2) (65%, p technology. Image quality was graded as similar between the evaluated systems (4.0 ± 0.7 vs 4.2 ± 0.6, not significant). In conclusion, a new x-ray technology with image noise reduction algorithm provides a substantial reduction in radiation exposure without the need to prolong the procedure or fluoroscopy time. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. T2*-based MR imaging (gradient echo or susceptibility-weighted imaging) in midline and off-midline intracranial germ cell tumors. A pilot study

    International Nuclear Information System (INIS)

    Morana, Giovanni; Tortora, Domenico; Severino, Mariasavina; Rossi, Andrea; Alves, Cesar Augusto; Finlay, Jonathan L.; Nozza, Paolo; Ravegnani, Marcello; Pavanello, Marco; Milanaccio, Claudia; Garre, Maria Luisa; Maghnie, Mohamad

    2018-01-01

    The role of T2*-based MR imaging in intracranial germ cell tumors (GCTs) has not been fully elucidated. The aim of this study was to evaluate the susceptibility-weighted imaging (SWI) or T2* gradient echo (GRE) features of germinomas and non-germinomatous germ cell tumors (NGGCTs) in midline and off-midline locations. We retrospectively evaluated all consecutive pediatric patients referred to our institution between 2005 and 2016, for newly diagnosed, treatment-naive intracranial GCT, who underwent MRI, including T2*-based MR imaging (T2* GRE sequences or SWI). Standard pre- and post-contrast T1- and T2-weighted imaging characteristics along with T2*-based MR imaging features of all lesions were evaluated. Diagnosis was performed in accordance with the SIOP CNS GCT protocol criteria. Twenty-four subjects met the inclusion criteria (17 males and 7 females). There were 17 patients with germinomas, including 5 basal ganglia primaries, and 7 patients with secreting NGGCT. All off-midline germinomas presented with SWI or GRE hypointensity; among midline GCT, all NGGCTs showed SWI or GRE hypointensity whereas all but one pure germinoma were isointense or hyperintense to normal parenchyma. A significant difference emerged on T2*-based MR imaging among midline germinomas, NGGCTs, and off-midline germinomas (p < 0.001). Assessment of the SWI or GRE characteristics of intracranial GCT may potentially assist in differentiating pure germinomas from NGGCT and in the characterization of basal ganglia involvement. T2*-based MR imaging is recommended in case of suspected intracranial GCT. (orig.)

  14. T2*-based MR imaging (gradient echo or susceptibility-weighted imaging) in midline and off-midline intracranial germ cell tumors. A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Morana, Giovanni; Tortora, Domenico; Severino, Mariasavina; Rossi, Andrea [Istituto Giannina Gaslini, Neuroradiology Unit, Genoa (Italy); Alves, Cesar Augusto [Hospital Das Clinicas, Radiology Department, Sao Paulo (Brazil); Finlay, Jonathan L. [Nationwide Children' s Hospital and The Ohio State University, Division of Hematology, Oncology and BMT, Columbus, OH (United States); Nozza, Paolo [Istituto Giannina Gaslini, Pathology Unit, Genoa (Italy); Ravegnani, Marcello; Pavanello, Marco [Istituto Giannina Gaslini, Neurosurgery Unit, Genoa (Italy); Milanaccio, Claudia; Garre, Maria Luisa [Istituto Giannina Gaslini, Neuro-oncology Unit, Genoa (Italy); Maghnie, Mohamad [Istituto Giannina Gaslini, University of Genova, Pediatric Endocrine Unit, Genoa (Italy)

    2018-01-15

    The role of T2*-based MR imaging in intracranial germ cell tumors (GCTs) has not been fully elucidated. The aim of this study was to evaluate the susceptibility-weighted imaging (SWI) or T2* gradient echo (GRE) features of germinomas and non-germinomatous germ cell tumors (NGGCTs) in midline and off-midline locations. We retrospectively evaluated all consecutive pediatric patients referred to our institution between 2005 and 2016, for newly diagnosed, treatment-naive intracranial GCT, who underwent MRI, including T2*-based MR imaging (T2* GRE sequences or SWI). Standard pre- and post-contrast T1- and T2-weighted imaging characteristics along with T2*-based MR imaging features of all lesions were evaluated. Diagnosis was performed in accordance with the SIOP CNS GCT protocol criteria. Twenty-four subjects met the inclusion criteria (17 males and 7 females). There were 17 patients with germinomas, including 5 basal ganglia primaries, and 7 patients with secreting NGGCT. All off-midline germinomas presented with SWI or GRE hypointensity; among midline GCT, all NGGCTs showed SWI or GRE hypointensity whereas all but one pure germinoma were isointense or hyperintense to normal parenchyma. A significant difference emerged on T2*-based MR imaging among midline germinomas, NGGCTs, and off-midline germinomas (p < 0.001). Assessment of the SWI or GRE characteristics of intracranial GCT may potentially assist in differentiating pure germinomas from NGGCT and in the characterization of basal ganglia involvement. T2*-based MR imaging is recommended in case of suspected intracranial GCT. (orig.)

  15. Relationship Between Working Memory and English-Chinese Consecu-tive Interpreting

    Institute of Scientific and Technical Information of China (English)

    王磊; 陈莉; 徐晓娟

    2016-01-01

    Working memory is the system that actively holds multiple pieces of transitory information in the mind, where they can be manipulated. In interpreting, working memory is in charge of the storage and processing of immediate information, thus making an important factor in influencing interpreting quality. The role played by working memory capacity in interpreting re-mains to be a hotspot issue in the field of interpreting research.This thesis aims to investigate the relationship between working memory capacity and E-C consecutive interpreting by conducting two tests. The first test is working memory span test and the second one is E-C consecutive interpreting test. By comparing and analyzing the results of two tests, this thesis comes to the con-clusion that working memory capacity is positively correlated with E-C consecutive interpreting in terms of fluency and logic.

  16. Fusion of MODIS and landsat-8 surface temperature images: a new approach.

    Science.gov (United States)

    Hazaymeh, Khaled; Hassan, Quazi K

    2015-01-01

    Here, our objective was to develop a spatio-temporal image fusion model (STI-FM) for enhancing temporal resolution of Landsat-8 land surface temperature (LST) images by fusing LST images acquired by the Moderate Resolution Imaging Spectroradiometer (MODIS); and implement the developed algorithm over a heterogeneous semi-arid study area in Jordan, Middle East. The STI-FM technique consisted of two major components: (i) establishing a linear relationship between two consecutive MODIS 8-day composite LST images acquired at time 1 and time 2; and (ii) utilizing the above mentioned relationship as a function of a Landsat-8 LST image acquired at time 1 in order to predict a synthetic Landsat-8 LST image at time 2. It revealed that strong linear relationships (i.e., r2, slopes, and intercepts were in the range 0.93-0.94, 0.94-0.99; and 2.97-20.07) existed between the two consecutive MODIS LST images. We evaluated the synthetic LST images qualitatively and found high visual agreements with the actual Landsat-8 LST images. In addition, we conducted quantitative evaluations of these synthetic images; and found strong agreements with the actual Landsat-8 LST images. For example, r2, root mean square error (RMSE), and absolute average difference (AAD)-values were in the ranges 084-0.90, 0.061-0.080, and 0.003-0.004, respectively.

  17. Split-Volume Treatment Planning of Multiple Consecutive Vertebral Body Metastases for Cyberknife Image-Guided Robotic Radiosurgery

    International Nuclear Information System (INIS)

    Sahgal, Arjun; Chuang, Cynthia; Larson, David; Huang, Kim; Petti, Paula; Weinstein, Phil; Ma Lijun

    2008-01-01

    Cyberknife treatment planning of multiple consecutive vertebral body metastases is challenging due to large target volumes adjacent to critical normal tissues. A split-volume treatment planning technique was developed to improve the treatment plan quality of such lesions. Treatment plans were generated for 1 to 5 consecutive thoracic vertebral bodies (CVBM) prescribing a total dose of 24 Gy in 3 fractions. The planning target volume (PTV) consisted of the entire vertebral body(ies). Treatment plans were generated considering both the de novo clinical scenario (no prior radiation), imposing a dose limit of 8 Gy to 1 cc of spinal cord, and the retreatment scenario (prior radiation) with a dose limit of 3 Gy to 1 cc of spinal cord. The split-volume planning technique was compared with the standard full-volume technique only for targets ranging from 2 to 5 CVBM in length. The primary endpoint was to obtain best PTV coverage by the 24 Gy prescription isodose line. A total of 18 treatment plans were generated (10 standard and 8 split-volume). PTV coverage by the 24-Gy isodose line worsened consistently as the number of CVBM increased for both the de novo and retreatment scenario. Split-volume planning was achieved by introducing a 0.5-cm gap, splitting the standard full-volume PTV into 2 equal length PTVs. In every case, split-volume planning resulted in improved PTV coverage by the 24-Gy isodose line ranging from 4% to 12% for the de novo scenario and, 8% to 17% for the retreatment scenario. We did not observe a significant trend for increased monitor units required, or higher doses to spinal cord or esophagus, with split-volume planning. Split-volume treatment planning significantly improves Cyberknife treatment plan quality for CVBM, as compared to the standard technique. This technique may be of particular importance in clinical situations where stringent spinal cord dose limits are required

  18. Effect of consecutive driving on accident risk: a comparison between passenger and freight train driving.

    Science.gov (United States)

    Chang, Hsin-Li; Ju, Lai-Shun

    2008-11-01

    This study combined driver-responsible accidents with on-board driving hours to examine the effect of consecutive driving on the accident risk of train operations. The data collected from the Taiwan Railway Administration for the period 1996-2006 was used to compute accident rates for varied accumulated driving hours for passenger and freight trains. The results showed that accident risk grew with increased consecutive driving hours for both passenger and freight trains, and doubled that of the first hour after four consecutive hours of driving. Additional accident risk was found for freight trains during the first hour due to required shunting in the marshalling yards where there are complex track layouts and semi-automatic traffic controls. Also, accident risk for train driving increased more quickly over consecutive driving hours than for automobile driving, and accumulated fatigue caused by high working pressure and monotony of the working environment are considered to be the part of the reason. To prevent human errors accidents, enhancing safety equipment, driver training programs, and establishing a sound auditing system are suggested and discussed.

  19. Consecutive opposed interactions of light waves

    International Nuclear Information System (INIS)

    Volkov, V V; Chirkin, Anatolii S

    1999-01-01

    The conditions were determined for the occurrence of the opposed interaction of waves having multiple frequencies in two consecutive three-frequency processes in periodically inhomogeneous nonlinear optical crystals. The necessary nonlinear susceptibility modulation period was calculated for an MgO:LiNbO 3 crystal. The characteristic features of the energy exchange between counterpropagating waves with parametric amplification in a low-frequency pump field were investigated. (nonlinear optical phenomena)

  20. Yield of two consecutive sputum specimens for the effective diagnosis of pulmonary tuberculosis.

    Directory of Open Access Journals (Sweden)

    Mohammad R Islam

    Full Text Available BACKGROUND: From long instances, it is debatable whether three sputum specimens are required for the diagnosis of pulmonary tuberculosis (TB or TB can be diagnosed effectively using two consecutive sputum specimens. This study was set out to evaluate the significance of examining multiple sputum specimens in diagnosis of TB. METHODS: We retrospectively reviewed the acid-fast bacillus (AFB smear and culture results of three consecutive days' sputum specimens from 413 confirmed TB patients which were detected as part of a larger active case finding study in Dhaka Central Jail, the largest correctional facility in Bangladesh. RESULTS: AFB was detected from 81% (n = 334 patients, of which 89% (n = 297 were diagnosed from the first and additional 9% (n = 30 were from the second sputum specimen. M. tuberculosis growth was observed for 406 patients and 85% (n = 343 were obtained from the first sputum and additional 10% (n = 42 were from the second one. The third specimen didn't show significant additional diagnostic value for the detection of AFB by microscopy or growth of the M. tuberculosis. CONCLUSIONS: We concluded from our study results that examining two consecutive sputum specimens is sufficient enough for the effective diagnosis of TB. It can also decrease the laboratory workload and hence improve the quality of work in settings with high TB burden like Bangladesh.

  1. Yield of two consecutive sputum specimens for the effective diagnosis of pulmonary tuberculosis.

    Science.gov (United States)

    Islam, Mohammad R; Khatun, Razia; Uddin, Mohammad Khaja Mafij; Khan, Md Siddiqur Rahman; Rahman, Md Toufiq; Ahmed, Tahmeed; Banu, Sayera

    2013-01-01

    From long instances, it is debatable whether three sputum specimens are required for the diagnosis of pulmonary tuberculosis (TB) or TB can be diagnosed effectively using two consecutive sputum specimens. This study was set out to evaluate the significance of examining multiple sputum specimens in diagnosis of TB. We retrospectively reviewed the acid-fast bacillus (AFB) smear and culture results of three consecutive days' sputum specimens from 413 confirmed TB patients which were detected as part of a larger active case finding study in Dhaka Central Jail, the largest correctional facility in Bangladesh. AFB was detected from 81% (n = 334) patients, of which 89% (n = 297) were diagnosed from the first and additional 9% (n = 30) were from the second sputum specimen. M. tuberculosis growth was observed for 406 patients and 85% (n = 343) were obtained from the first sputum and additional 10% (n = 42) were from the second one. The third specimen didn't show significant additional diagnostic value for the detection of AFB by microscopy or growth of the M. tuberculosis. We concluded from our study results that examining two consecutive sputum specimens is sufficient enough for the effective diagnosis of TB. It can also decrease the laboratory workload and hence improve the quality of work in settings with high TB burden like Bangladesh.

  2. Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.

    Science.gov (United States)

    Sunwoo, Leonard; Kim, Young Jae; Choi, Seung Hong; Kim, Kwang-Gi; Kang, Ji Hee; Kang, Yeonah; Bae, Yun Jung; Yoo, Roh-Eul; Kim, Jihang; Lee, Kyong Joon; Lee, Seung Hyun; Choi, Byung Se; Jung, Cheolkyu; Sohn, Chul-Ho; Kim, Jae Hyoung

    2017-01-01

    To assess the effect of computer-aided detection (CAD) of brain metastasis (BM) on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR) imaging using follow-up imaging and consensus as the reference standard. The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents) interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP) per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC) method was used to determine the improvement in the diagnostic accuracy. The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM) of 0.874 (without CAD) vs. 0.898 (with CAD) according to JAFROC analysis (p reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p review the CAD results was approximately 72 sec (40% of the total review time). CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

  3. Severe Degeneration of the Medial Collateral Ligament in Hallux Valgus: A Histopathologic Study in 12 Consecutive Patients

    Science.gov (United States)

    Prasitdumrong, Ittipol; Rungprai, Chamnanni; Reeboonlarb, Nitit; Poonpracha, Tara; Phisitkul, Phinit

    2013-01-01

    Objective To determine the degree and location of degenerative changes of the medial collateral ligament of the first metatarsophalangeal joint, using the lateral collateral ligament as a control, in patients undergoing hallux valgus correction. Materials and Methods A strip of medial and lateral collateral ligaments were biopsied from 12 consecutive patients (age 45 ± 4.8 years) with symptomatic hallux valgus. A blinded analysis of histopathology was performed by an experienced pathologist. Results The medial collateral ligament was significantly more degenerated compared to the lateral collateral ligament (x2 = 23.41, DF = 2, p hallux valgus correction. The Authors received no financial support for this study. PMID:24027461

  4. Laparoscopic Cholecystectomy: One Surgeon’s Experience in 100 Consecutive Cases

    OpenAIRE

    1994-01-01

    Initial 100 consecutive laparoscopic cholecystectomies performed by one surgeon were studied prospectively. The standard technique was modified in that the gallbladder removal was accomplished through the upper epigastric incision; there was no need to change the location of the camera. The conversion rate to open cholecystectomy was 2%. There were no major complications and no mortality. Minor complications occurred in 9% of the patients. Laparoscopic cholecystectomy can be performed safely ...

  5. Do Foley Catheters Adequately Drain the Bladder? Evidence from CT Imaging Studies

    Directory of Open Access Journals (Sweden)

    Svetlana Avulova

    2015-06-01

    Full Text Available ABSTRACTIntroduction:The Foley catheter has been widely assumed to be an effective means of draining the bladder. However, recent studies have brought into question its efficacy. The objective of our study is to further assess the adequacy of Foley catheter for complete drainage of the bladder.Materials and Methods:Consecutive catheterized patients were identified from a retrospective review of contrast enhanced and non-contrast enhanced computed tomo-graphic (CT abdomen and pelvis studies completed from 7/1/2011-6/30/2012. Residual urine volume (RUV was measured using 5mm axial CT sections as follows: The length (L and width (W of the bladder in the section with the greatest cross sectional area was combined with bladder height (H as determined by multiplanar reformatted images in order to calculate RUV by applying the formula for the volume (V of a sphere in a cube: V=(ϖ/6*(L*W*H.Results:RUVs of 167 (mean age 67 consecutively catheterized men (n=72 and women (n=95 identified by CT abdomen and pelvis studies were calculated. The mean RUV was 13.2 mL (range: 0.0 mL-859.1 mL, standard deviation: 75.9 mL, margin of error at 95% confidence:11.6 mL. Four (2.4% catheterized patients had RUVs of >50 mL, two of whom had an improperly placed catheter tip noted on their CT-reports.Conclusions:Previous studies have shown that up to 43% of catheterized patients had a RUV greater than 50 mL, suggesting inadequacy of bladder drainage via the Foley catheter. Our study indicated that the vast majority of patients with Foley catheters (97.6%, had adequately drained bladders with volumes of

  6. Do Foley catheters adequately drain the bladder? Evidence from CT imaging studies

    Energy Technology Data Exchange (ETDEWEB)

    Avulova, Svetlana; Li, Valery J.; Khusid, Johnathan A. [Department of Urology, SUNY Downstate College of Medicine, Brooklyn, NY (United States); Choi, Woo S. [Radiology, SUNY Downstate College of Medicine, Brooklyn, NY (United States); Weiss, Jeffrey P., E-mail: johnathan.khusid@downstate.edu [Department of Urology, Weill Cornell Medical College, New York, NY (United States)

    2015-05-15

    Introduction: The Foley catheter has been widely assumed to be an effective means of draining the bladder. However, recent studies have brought into question its efficacy. The objective of our study is to further assess the adequacy of Foley catheter for complete drainage of the bladder. Materials and Methods: Consecutive catheterized patients were identified from a retrospective review of contrast enhanced and non-contrast enhanced computed tomographic (CT) abdomen and pelvis studies completed from 7/1/2011-6/30/2012. Residual urine volume (RUV) was measured using 5mm axial CT sections as follows: The length (L) and width (W) of the bladder in the section with the greatest cross sectional area was combined with bladder height (H) as determined by multiplanar reformatted images in order to calculate RUV by applying the formula for the volume (V) of a sphere in a cube:V=(π/6)⁎L⁎W⁎H). Results: RUVs of 167 (mean age 67) consecutively catheterized men (n=72) and women (n=95) identified by CT abdomen and pelvis studies were calculated. The mean RUV was 13.2 mL (range: 0.0 mL-859.1 mL, standard deviation: 75.9 mL, margin of error at 95% confidence:11.6 mL). Four (2.4%) catheterized patients had RUVs of >50 mL, two of whom had an improperly placed catheter tip noted on their CT-reports. Conclusions: Previous studies have shown that up to 43% of catheterized patients had a RUV greater than 50 mL, suggesting inadequacy of bladder drainage via the Foley catheter. Our study indicated that the vast majority of patients with Foley catheters (97.6%), had adequately drained bladders with volumes of <50 mL. (author)

  7. Pathology of the heart in AIDS. A study of 60 consecutive autopsies

    DEFF Research Database (Denmark)

    Hansen, B F

    1992-01-01

    Cardiac disease and cardiac death in AIDS patients is seldom reported. In recent years minor cardiac abnormalities have been demonstrated, especially by echocardiography. Cardiac pathology in AIDS patients is here reported from 60 consecutive autopsies where the heart was investigated either using...... single samples of ventricular myocardium (the first 21 cases) or by an examination of the whole heart (the last 39 cases). Myocarditis according to the Dallas criteria was seen in 25 of 60 cases (42%), and in seven of these cases a probable pathogen (Toxoplasma gondii, cytomegalovirus, fungi...... heart was performed, there was dilation and/or hypertrophy of the right ventricle. This is in agreement with our knowledge that the main diseases and main causes of death in AIDS patients are pulmonary. Survival time in AIDS is increasing due to ever improving symptomatic treatment, and the results...

  8. Etiology of azoospermia in 100 consecutive nonvasectomized men

    DEFF Research Database (Denmark)

    Fedder, Jens; Crüger, Dorthe; Oestergaard, Birthe

    2004-01-01

    History was taken systematically for 100 azoospermic, nonvasectomized men referred consecutively to a Danish fertility clinic. The men were examined by ultrasound, and their blood samples were analyzed for karyotype, Y microdeletions, and cystic fibrosis transmembrane conductance regulator gene...

  9. Fast spin-echo MR imaging of the eye

    International Nuclear Information System (INIS)

    Hosten, N.; Lemke, A.J.; Bornfeld, N.; Wassmuth, R.; Schweiger, U.; Terstegge, K.; Felix, R.

    1996-01-01

    Magnetic resonance imaging of the eye usually includes T2-weighted images both for screening purposes and for characterization of melanoma. Conventional T2-weighted spin-echo (SE) imaging suffers both from long acquisition times and incomplete recovery of the virteous' signal. A fast SE sequence was therefore compared prospectively with conventional sequences in 29 consecutive patients with lesions of the eye. Fast SE images delineated melanoma and other lesions of the eye from vitreous better than conventional T2-weighted images. Image quality and lesion conspicuity were improved on the fast sequence. Whereas melanoma appeared hypointense to vitreous on both types of images, subretinal effusion was hypointense on fast images and hyperintense on conventional T2-weighted images. Ghosting of the globe, which, however, did not decrease diagnostic value, was more pronounced on fast images. Conventional T2-weighted images may be replaced by fast SE images in MR studies of the eye with a gain in lesion conspicuity and significant time saving. (orig.)

  10. The consecutive dry days to trigger rainfall over West Africa

    Science.gov (United States)

    Lee, J. H.

    2018-01-01

    In order to resolve contradictions in addressing a soil moisture-precipitation feedback mechanism over West Africa and to clarify the impact of antecedent soil moisture on subsequent rainfall evolution, we first validated various data sets (SMOS satellite soil moisture observations, NOAH land surface model, TRMM rainfall, CMORPH rainfall and HadGEM climate models) with the Analyses Multidisciplinaires de la Mousson Africaine (AMMA) field campaign data. Based on this analysis, it was suggested that biases of data sets might cause contradictions in studying mechanisms. Thus, by taking into account uncertainties in data, it was found that the approach of consecutive dry days (i.e. a relative comparison of time-series) showed consistency across various data sets, while the direct comparison approach for soil moisture state and rainfall did not. Thus, it was discussed that it may be difficult to directly relate rain with soil moisture as the absolute value, however, it may be reasonable to compare a temporal progress of the variables. Based upon the results consistently showing a positive relationship between the consecutive dry days and rainfall, this study supports a negative feedback often neglected by climate model structure. This approach is less sensitive to interpretation errors arising from systematic errors in data sets, as this measures a temporal gradient of soil moisture state.

  11. Iron Supplementation during Three Consecutive Days of Endurance Training Augmented Hepcidin Levels

    Directory of Open Access Journals (Sweden)

    Aya Ishibashi

    2017-07-01

    Full Text Available Iron supplementation contributes an effort to improving iron status among athletes, but it does not always prevent iron deficiency. In the present study, we explored the effect of three consecutive days of endurance training (twice daily on the hepcidin-25 (hepcidin level. The effect of iron supplementation during this period was also determined. Fourteen male endurance athletes were enrolled and randomly assigned to either an iron-treated condition (Fe condition, n = 7 or a placebo condition (Control condition; CON, n = 7. They engaged in two 75-min sessions of treadmill running at 75% of maximal oxygen uptake on three consecutive days (days 1–3. The Fe condition took 12 mg of iron twice daily (24 mg/day, and the CON condition did not. On day 1, both conditions exhibited significant increases in serum hepcidin and plasma interleukin-6 levels after exercise (p < 0.05. In the CON condition, the hepcidin level did not change significantly throughout the training period. However, in the Fe condition, the serum hepcidin level on day 4 was significantly higher than that of the CON condition (p < 0.05. In conclusion, the hepcidin level was significantly elevated following three consecutive days of endurance training when moderate doses of iron were taken.

  12. Iron Supplementation during Three Consecutive Days of Endurance Training Augmented Hepcidin Levels.

    Science.gov (United States)

    Ishibashi, Aya; Maeda, Naho; Kamei, Akiko; Goto, Kazushige

    2017-07-30

    Iron supplementation contributes an effort to improving iron status among athletes, but it does not always prevent iron deficiency. In the present study, we explored the effect of three consecutive days of endurance training (twice daily) on the hepcidin-25 (hepcidin) level. The effect of iron supplementation during this period was also determined. Fourteen male endurance athletes were enrolled and randomly assigned to either an iron-treated condition (Fe condition, n = 7) or a placebo condition (Control condition; CON, n = 7). They engaged in two 75-min sessions of treadmill running at 75% of maximal oxygen uptake on three consecutive days (days 1-3). The Fe condition took 12 mg of iron twice daily (24 mg/day), and the CON condition did not. On day 1, both conditions exhibited significant increases in serum hepcidin and plasma interleukin-6 levels after exercise ( p < 0.05). In the CON condition, the hepcidin level did not change significantly throughout the training period. However, in the Fe condition, the serum hepcidin level on day 4 was significantly higher than that of the CON condition ( p < 0.05). In conclusion, the hepcidin level was significantly elevated following three consecutive days of endurance training when moderate doses of iron were taken.

  13. Success of Unsplinted Implant-Retained Removable Mandibular and Maxillary Overdentures: A Retrospective Study of Consecutive Cases.

    Science.gov (United States)

    Strong, Samuel M

    2015-01-01

    Implant-retained overdentures have been provided on both splinted and freestanding implants. For the mandible, a long history shows that both approaches can be successful over the long term. For the maxilla, many clinicians prefer to splint the implants because of concerns about softer bone quality and insufficient data supporting the use of freestanding overdenture abutments. However, a few investigations have found survival rates for unsplinted maxillary overdentures to be comparable to those for splinted ones. The present study analyzed records of consecutive patients who were treated with unsplinted maxillary and mandibular overdentures and followed for 4 to 107 months. A total of 31 overdentures were identified, 15 maxillary and 16 mandibular, supported by 129 implants. All the overdentures, along with all the implants, survived throughout the follow-up period.

  14. Condensed images for evaluating gastric motility patterns

    Energy Technology Data Exchange (ETDEWEB)

    Tatsch, K.; Schroettle, W.; Kirsch, C.-M. (Munich Univ. (Germany, F.R.). Dept. of Radiology)

    1991-04-01

    A condensed imaging technique was applied to gastric emptying studies to investigate (a) whether different types of motility disorders may be distinguished by characteristic image patterns and (b) whether the findings obtained provide additional information compared to standard quantitative measurements. Condensed images and quantitative data of gastric emptying were evaluated in 75 consecutive patients with normal function and various disorders such as peptic ulcer, postvagotomy, pyloric obstruction, dumping syndrome, gastoparesis etc. Condensed images were generated from a gastric region of interest. They display the distribution and behaviour of a radioactive test meal in a space-time matrix, whose horizontal and vertical dimensions are temporal and spatial, respectively. As shown in a series of representative examples condensed images disclose a variety of well-defined image patterns reflecting different pathophysiological mechanisms. This qualitative characterization of gastric emptying patterns provided in 34 of the 75 patients (45%) important new information compared to quantitative data. The application of condensed imaging techniques to gastric emptying studies (complementary to quantitative measurements) may, therefore, enhance the diagnostic value of scintigraphic techniques. (author).

  15. [A naturalistic study: 100 consecutive episodes of acute agitation in a psychiatric emergency department].

    Science.gov (United States)

    Pascual, J C; Madre, M; Puigdemont, D; Oller, S; Corripio, I; Díaz, A; Faus, G; Perez, V; Alvarez, E

    2006-01-01

    Psychomotor agitation is a common event in psychiatric emergency services (PES) with a prevalence of approximately 10 %. There is no general consensus on to how to manage psychomotor agitation; benzodiazepines, typical antipsychotics and now atypical antipsychotics have demonstrated similar efficacy. The aim of our study was to describe the epidemiology and clinical management of agitation in "real-life" in a psychiatric emergency service. A naturalistic study was performed in acutely agitated patients recruited consecutively in a psychiatric emergency service. Demographics, clinical and therapeutic characteristics were analyzed. Efficacy was assessed by the Excitement Component of the Positive and Negative Syndrome Scale (PANSS-EC) and the Agitation-Calmness Evaluation Scale (ACES). Pragmatic variables such as the need for second pharmacological intervention and the need for physical restraints were assessed. The study included 100 patients with psychomotor agitation. Mean age was 36.2 % and 54% were women. The most prevalent diagnoses were psychotic disorder (48 %) and personality disorder (24 %). Physical restraint was required in 39 % of patients and 52 % accepted oral treatment. Haloperidol was the most frequent oral treatment and olanzapine was the most frequent intramuscular treatment. A naturalistic approach provides data based on clinical reality in psychiatric emergency services. Strict research designs of clinical trials of efficacy imply sample selection biases and are generally distanced from the clinical reality. Atypical antipsychotics have become the first-line treatment in acute agitation

  16. Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.

    Directory of Open Access Journals (Sweden)

    Leonard Sunwoo

    Full Text Available To assess the effect of computer-aided detection (CAD of brain metastasis (BM on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR imaging using follow-up imaging and consensus as the reference standard.The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC method was used to determine the improvement in the diagnostic accuracy.The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM of 0.874 (without CAD vs. 0.898 (with CAD according to JAFROC analysis (p < 0.01. Statistically significant improvement was noted only for less-experienced reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p < 0.01. The additional time required to review the CAD results was approximately 72 sec (40% of the total review time.CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

  17. Fifty consecutive pancreatectomies without mortality

    Directory of Open Access Journals (Sweden)

    Enio Campos Amico

    Full Text Available Objective: to report the group's experience with a series of patients undergoing pancreatic resection presenting null mortality rates. Methods: we prospectively studied 50 consecutive patients undergoing pancreatic resections for peri-ampullary or pancreatic diseases. Main local complications were defined according to international criteria. In-hospital mortality was defined as death occurring in the first 90 postoperative days. Results: patients' age ranged between 16 and 90 years (average: 53.3. We found anemia (Hb < 12g/dl and preoperative jaundice in 38% and 40% of cases, respectively. Most patients presented with peri-ampullary tumors (66%. The most common surgical procedure was the Kausch - Whipple operation (70%. Six patients (12% needed to undergo resection of a segment of the mesenteric-portal axis. The mean operative time was 445.1 minutes. Twenty two patients (44% showed no clinical complications and presented mean hospital stay of 10.3 days. The most frequent complications were pancreatic fistula (56%, delayed gastric emptying (17.1% and bleeding (16%. Conclusion : within the last three decades, pancreatic resection is still considered a challenge, especially outside large specialized centers. Nevertheless, even in our country (Brazil, teams seasoned in such procedure can reach low mortality rates.

  18. Androgen excess in women: experience with over 1000 consecutive patients.

    Science.gov (United States)

    Azziz, R; Sanchez, L A; Knochenhauer, E S; Moran, C; Lazenby, J; Stephens, K C; Taylor, K; Boots, L R

    2004-02-01

    The objective of the present study was to estimate the prevalence of the different pathological conditions causing clinically evident androgen excess and to document the degree of long-term success of suppressive and/or antiandrogen hormonal therapy in a large consecutive population of patients. All patients presenting for evaluation of symptoms potentially related to androgen excess between October 1987 and June 2002 were evaluated, and the data were maintained prospectively in a computerized database. For the assessment of therapeutic response, a retrospective review of the medical chart was performed, after the exclusion of those patients seeking fertility therapy only, or with inadequate follow-up or poor compliance. A total of 1281 consecutive patients were seen during the study period. Excluded from analysis were 408 patients in whom we were unable to evaluate hormonal status, determine ovulatory status, or find any evidence of androgen excess. In the remaining population of 873 patients, the unbiased prevalence of androgen-secreting neoplasms was 0.2%, 21-hydroxylase-deficient classic adrenal hyperplasia (CAH) was 0.6%, 21-hydroxylase-deficient nonclassic adrenal hyperplasia (NCAH) was 1.6%, hyperandrogenic insulin-resistant acanthosis nigricans (HAIRAN) syndrome was 3.1%, idiopathic hirsutism was 4.7%, and polycystic ovary syndrome (PCOS) was 82.0%. Fifty-nine (6.75%) patients had elevated androgen levels and hirsutism but normal ovulation. A total of 257 patients were included in the assessment of the response to hormonal therapy. The mean duration of follow-up was 33.5 months (range, 6-155). Hirsutism improved in 86%, menstrual dysfunction in 80%, acne in 81%, and hair loss in 33% of patients. The major side effects noted were irregular vaginal bleeding (16.1%), nausea (13.0%), and headaches (12.6%); only 36.6% of patients never complained of side effects. In this large study of consecutive patients presenting with clinically evident androgen excess

  19. Novel free-hand T1 pedicle screw method: Review of 44 consecutive cases

    Directory of Open Access Journals (Sweden)

    Mark A Rivkin

    2014-01-01

    Full Text Available Summary of Background Data: Multilevel posterior cervical instrumented fusions are becoming more prevalent in current practice. Biomechanical characteristics of the cervicothoracic junction may necessitate extending the construct to upper thoracic segments. However, fixation in upper thoracic spine can be technically demanding owing to transitional anatomy while suboptimal placement facilitates vascular and neurologic complications. Thoracic instrumentation methods include free-hand, fluoroscopic guidance, and CT-based image guidance. However, fluoroscopy of upper thoracic spine is challenging secondary to vertebral geometry and patient positioning, while image-guided systems present substantial financial commitment and are not readily available at most centers. Additionally, imaging modalities increase radiation exposure to the patient and surgeon while potentially lengthening surgical time. Materials and Methods: Retrospective review of 44 consecutive patients undergoing a cervicothoracic fusion by a single surgeon using the novel free-hand T1 pedicle screw technique between June 2009 and November 2012. A starting point medial and cephalad to classic entry as well as new trajectory were utilized. No imaging modalities were employed during screw insertion. Postoperative CT scans were obtained on day 1. Screw accuracy was independently evaluated according to the Heary classification. Results: In total, 87 pedicle screws placed were at T1. Grade 1 placement occurred in 72 (82.8% screws, Grade 2 in 4 (4.6% screws and Grade 3 in 9 (10.3% screws. All Grade 2 and 3 breaches were <2 mm except one Grade 3 screw breaching 2-4 mm laterally. Only two screws (2.3% were noted to be Grade 4, both breaching medially by less than 2 mm. No new neurological deficits or returns to operating room took place postoperatively. Conclusions: This modification of the traditional starting point and trajectory at T1 is safe and effective. It attenuates additional bone

  20. Reconstruction of alveolar defects in patients with cleft lip and palate - 111 consecutive patients

    DEFF Research Database (Denmark)

    Andersen, Kristian

    2012-01-01

    Reconstruction of alveolar defects in patients with cleft lip and palate - 111 consecutive patients......Reconstruction of alveolar defects in patients with cleft lip and palate - 111 consecutive patients...

  1. Conventional imaging in paediatric uroradiology

    International Nuclear Information System (INIS)

    Riccabona, M.; Lindbichler, F.; Sinzig, M.

    2002-01-01

    Objective: To briefly describe basic conventional imaging in paediatric uroradiology. Method: The state of the art performance of standard imaging techniques (intravenous urography (IVU), voiding cystourethrography (VCU), and ultrasound (US)) is described, with emphasis on technical aspects, indications, and patient preparation such as adequate hydration. Only basic applications as used in routine clinical work are included. Result and conclusion: Conventional imaging methods are irreplaceable. They cover the majority of daily clinical routine queries, with consecutive indication of more sophisticated modalities in those patients who need additional imaging for establishing the final diagnosis or outlining therapeutic options

  2. Conventional imaging in paediatric uroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Riccabona, M. E-mail: michael.riccabona@kfunigraz.ac.at; Lindbichler, F.; Sinzig, M

    2002-08-01

    Objective: To briefly describe basic conventional imaging in paediatric uroradiology. Method: The state of the art performance of standard imaging techniques (intravenous urography (IVU), voiding cystourethrography (VCU), and ultrasound (US)) is described, with emphasis on technical aspects, indications, and patient preparation such as adequate hydration. Only basic applications as used in routine clinical work are included. Result and conclusion: Conventional imaging methods are irreplaceable. They cover the majority of daily clinical routine queries, with consecutive indication of more sophisticated modalities in those patients who need additional imaging for establishing the final diagnosis or outlining therapeutic options.

  3. Relationship between consecutive deterioration of mean deviation value and progression of visual field defect in open-angle glaucoma.

    Science.gov (United States)

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Takeda, Ryuji; Shiraga, Fumio

    2015-01-01

    To analyze the relationship between consecutive deterioration of mean deviation (MD) value and glaucomatous visual field (VF) progression in open-angle glaucoma (OAG), including primary OAG and normal tension glaucoma. The subjects of the study were patients undergoing treatment for OAG who had performed VF tests at least 10 times with a Humphrey field analyzer (SITA standard, C30-2 program). The VF progression was defined by a significantly negative MD slope (MD slope worsening) at the final VF test during the follow-up period. The relationship between the MD slope worsening and the consecutive deterioration of MD value were retrospectively analyzed. A total of 165 eyes of 165 patients were included in the analysis. Significant progression of VF defects was observed in 72 eyes of 72 patients (43.6%), while no significant progression was evident in 93 eyes of 93 patients (56.4%). There was significant relationship between the frequency of consecutive deterioration of MD value and MD slope worsening (P<0.0001, Cochran-Armitage trend test). A significant association was observed for MD slope worsening in the eyes with three (odds ratio: 2.1, P=0.0224) and four (odds ratio: 3.6, P=0.0008) consecutive deterioration of MD value in multiple logistic regression analysis, but no significant association in the eyes with two consecutive deterioration (odds ratio: 1.1, P=0.8282). The eyes with VF progression had significantly lower intraocular pressure reduction rate (P<0.01). This retrospective study has shown that three or more consecutive deterioration of MD value might be a predictor to future significant MD slope worsening in OAG.

  4. Late urologic morbidity in 177 consecutive patients after radiotherapy for cervical carcinoma: a longitudinal study

    International Nuclear Information System (INIS)

    Lajer, Henrik; Thranov, Ingrid R.; Skovgaard, Lene T.; Engelholm, Svend Aa

    2002-01-01

    Purpose: To provide longitudinal data on urologic morbidity after radiotherapy and brachytherapy for cervical carcinoma. Methods and Materials: Five-year longitudinal urologic morbidity data were recorded from 177 consecutive patients of median age 59 years (range: 22-86 years) with cervical carcinoma receiving radiotherapy with curative intent at the Copenhagen University Hospital, Denmark. FIGO stages (%) were as follows: Stage I (15), Stage II (30), Stage III (54), and Stage IV (1). Late morbidity was calculated as cumulative incidence based on actuarial estimates. Results: The 5-year cumulative incidence based on actuarial estimates of urologic morbidity Grades 1 + 2 + 3, Grades 2 + 3, and Grade 3 were 62%, 32%, and 5%, respectively. Frequencies of urologic morbidity in the 54 recurrence-free survivors at the end of follow-up indicated some reversibility in the case of Grades 1 and 2 morbidity. Conclusion: With the longitudinal design used in the present study, a rate of mild and moderate morbidity higher than that found in most of the previously reported literature was observed, giving cause for concern and underlining the importance of further longitudinal studies on this subject, specifically studies that relate to the background urologic morbidity in the female population, as well as to the fact that urologic morbidity might regress

  5. MR imaging of medullary compression due to vertebral metastases

    International Nuclear Information System (INIS)

    Dooms, G.C.; Mathurin, P.; Maldague, B.; Cornelis, G.; Malghem, J.; Demeure, R.

    1987-01-01

    A prospective study was performed to assess the value of MR imaging for demonstrating medullary compression due to vertebral metastases in cancer patients clinically suspected of presenting with that complication. Twenty-five consecutive unselected patients were studied, and the MR imaging findings were confirmed by myelography, CT, and/or surgical and autopsy findings for each patient. The MR examinations were performed with a superconducting magnet (Philips Gyroscan S15) operating at 0.5-T. MR imaging demonstrated the metastases (single or multiple) mainly on T1- weighted images (TR = 0.45 sec and TE = 20 msec). Soft-tissue tumoral mass and/or deformity of a vertebral body secondary to metastasis, compressing the spinal cord, was equally demonstrated on T1- and heavily T2-weighted images (TR = 1.65 sec and TE = 100 msec). In the sagittal plane, MR imaging demonstrated the exact level of the compression (one or multiple levels) and its full extent. In conclusion, MR is the first imaging modality for studying cancer patients with clinically suspected medullary compression and obviates the need for more invasive procedures

  6. Two consecutive levels of unilateral cervical spondylolysis on opposite sides

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Kyeong Hwa; Kim, Seon Jeong; KIm Ok Hwa; Kim, Seung Ho; Lee, Kwang Hwi; Beak, Hye Jin; Lee, Ye Daun [Dept. of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan (Korea, Republic of); Cha, Yoon Ki [Dept. of Radiology, Dongguk University College of Medicine, Ilsan Hospital, Goyang (Korea, Republic of)

    2015-09-15

    Cervical spondylolysis, with or without spondylolisthesis, is a rare condition defined as a corticated cleft between the superior and inferior articular facets of the articular pillar. The defect occurs predominantly at C6, and is usually bilateral in up to two-thirds of cases. Multilevel involvement is uncommon, however, to date, no case of two consecutive levels of unilateral cervical spondylolysis on opposite sides has been reported. Here, we report a rare case of a patient affected by two consecutive levels of unilateral cervical spondylolysis at C5 and C6 on opposite sides in a 19-year-old male complaining of neck pain.

  7. Two consecutive levels of unilateral cervical spondylolysis on opposite sides

    International Nuclear Information System (INIS)

    Ryu, Kyeong Hwa; Kim, Seon Jeong; KIm Ok Hwa; Kim, Seung Ho; Lee, Kwang Hwi; Beak, Hye Jin; Lee, Ye Daun; Cha, Yoon Ki

    2015-01-01

    Cervical spondylolysis, with or without spondylolisthesis, is a rare condition defined as a corticated cleft between the superior and inferior articular facets of the articular pillar. The defect occurs predominantly at C6, and is usually bilateral in up to two-thirds of cases. Multilevel involvement is uncommon, however, to date, no case of two consecutive levels of unilateral cervical spondylolysis on opposite sides has been reported. Here, we report a rare case of a patient affected by two consecutive levels of unilateral cervical spondylolysis at C5 and C6 on opposite sides in a 19-year-old male complaining of neck pain

  8. Prognostic classification with laboratory parameters or imaging techniques in small-cell lung cancer

    NARCIS (Netherlands)

    de Jong, Wouter K.; Fidler, Vaclav; Groen, Harry J. M.

    PURPOSE: Our aim in this study was to compare prognostic models based on laboratory tests with a model including imaging information in small-cell lung cancer. PATIENTS AND METHODS: A retrospective analysis was performed on 156 consecutive patients. Three existing models based on laboratory tests

  9. Profiles of US and CT imaging features with a high probability of appendicitis

    NARCIS (Netherlands)

    van Randen, A.; Laméris, W.; van Es, H.W.; ten Hove, W.; Bouma, W.H.; van Leeuwen, M.S.; van Keulen, E.M.; van der Hulst, V.P.M.; Henneman, O.D.; Bossuyt, P.M.; Boermeester, M.A.; Stoker, J.

    2010-01-01

    To identify and evaluate profiles of US and CT features associated with acute appendicitis. Consecutive patients presenting with acute abdominal pain at the emergency department were invited to participate in this study. All patients underwent US and CT. Imaging features known to be associated with

  10. Measurement of gastric emptying by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Furukawa, Akira; Kiyota, Keisuke; Takazakura, Ryutaro; Inokuchi, Hideto [Osaka Saiseikai Noe Hospital (Japan); Murata, Kiyoshi; Morita, Rikushi

    1996-02-01

    The purpose of the study was to establish a new method of measuring gastric emptying using MR imaging in human. Gastric emptying was measured in 6 healthy male volunteers aged from 28 to 43 years, using MR imaging and RI. The measurements were performed after the oral administration of liquid meal containing glucose, protein and fat. The MR imaging was performed with 0.5T superconducting magnet machine, and consecutive 12 transaxial T1 weighted spin echo images (TR/TE=300/17) of the upper abdomen were recorded every 10 minutes for more than 1 hour. Gastric emptying curves and their T1/2 values obtained by MR imaging and RI method were correlated well in 5 of 6 cases. We concluded that a non-invasive and radiation free method using MR imaging was proved to be a useful tool for measuring gastric emptying. (author).

  11. Dual-isotope myocardial imaging: feasibility, advantages and limitations. Preliminary report on 231 consecutive patients

    International Nuclear Information System (INIS)

    Weinmann, P.; Foult, J.M.; Le Guludec, D.; Tamgac, F.; Rechtman, D.; Neuman, A.; Caillat-Vigneron, N.; Moretti, J.L.

    1994-01-01

    Two hundred and thirty-one patients underwent dual-isotope myocardial imaging (rest thallium-201 followed by stress technetium-99m sestamibi). The feasibility of the procedure was excellent: camera scheduling flexibility was improved and the duration of the procedure was less than that of a classical stress-redistribution procedure. Interpretation of defects due to image attenuation was facilitated by the different attenuation properties of 201 Tl and 99m Tc-sestamibi in 11 of 19 patients. 201 Tl cross-over on 99m Tc was found to be 15% ± 3% with doses of 201 Tl and 99m Tc-sestamibi of 3 and 10 mCi, respectively, and 7% ± 2% with doses of 3 and 20 mCi. This protocol should preferentially be reserved for patients with a history of myocardial infarction and/or a basal left ventricular dysfunction, in whom assessment of myocardial viability is of major interest. (orig./MG)

  12. Laparoscopic Cholecystectomy: One Surgeon’s Experience in 100 Consecutive Cases

    Directory of Open Access Journals (Sweden)

    Ivan J Pokorny

    1994-01-01

    Full Text Available Initial 100 consecutive laparoscopic cholecystectomies performed by one surgeon were studied prospectively. The standard technique was modified in that the gallbladder removal was accomplished through the upper epigastric incision; there was no need to change the location of the camera. The conversion rate to open cholecystectomy was 2%. There were no major complications and no mortality. Minor complications occurred in 9% of the patients. Laparoscopic cholecystectomy can be performed safely in a community hospital setting. Simplified technique of gallbladder extraction is recommended.

  13. Mesenteric panniculitis: systematic review of cross-sectional imaging findings and risk of subsequent malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Halligan, Steve; Plumb, Andrew; Taylor, Stuart [University College London UCL, Centre for Medical Imaging, 3rd Floor East, London (United Kingdom)

    2016-12-15

    Systematic review to determine any association between imaging features of idiopathic mesenteric panniculitis (MP) and subsequent malignancy. Two researchers searched primary literature independently for imaging studies of MP. They extracted data focusing on methodology for unbiased patient accrual and capability to determine a link between MP and subsequent malignancy. They noted imaging features of MP. Data were accrued and meta-analysis intended. Fourteen of 675 articles were eligible; 1,226 patients. Only three (21 %) accrued patients prospectively. Twelve (86 %) studies described CT features. Follow-up varied widely; 1 month to 8 years. Prevalence of MP was influenced by accrual: 0.2 % for keyword search versus 1.7 % for consecutive series. Accrual bias affected nine (64 %) studies. 458 (38 %) of 1,209 patients had malignancy at accrual but varied widely (8-89 %), preventing meta-analysis. Sixty (6.4 %) of 933 patients developed new malignancy subsequently, also varying widely (0-11 %). Of just four studies that determined the proportion of unselected, consecutive patients with MP developing subsequent malignancy, three were retrospective and the fourth excluded patients with lymphadenopathy, likely excluding patients with MP. Studies were heterogeneous, with biased accrual. No available study can determine an association between MP and subsequent malignancy with certainty. (orig.)

  14. Flight Hours in 7 Consecutive Days and Physical Exercise among the Civil Pilot in Indonesia

    Directory of Open Access Journals (Sweden)

    Harry Wicaksana

    2017-07-01

    Full Text Available Abstrak Latar belakang Tidak tersedianya waktu merupakan salah satu hambatan melakukan latihan fisik yang sering dilaporkan di negara berkembang. Berdasarkan Peraturan Keselamatan Penerbangan Sipil bagian 121, jam terbang maksimal pilot sipil komersial dalam 7 hari terakhir adalah 30 jam. Oleh karena itu perlu dilakukan penelitian mengenai hubungan jam terbang 7 hari terakhir terhadap kebiasaan latihan fisik pada pilot sipil di Indonesia. Metode Penelitian potong lintang terhadap 600 orang pilot sipil yang melakukan pengujian kesehatan personil penerbangan di Balai Kesehatan Penerbangan pada bulan April 2016 dan memenuhi kriteria inklusi/ekslusi.  Data yang dikumpulkan yaitu karakteristik demografi, pekerjaan, kebiasaan olahraga, tinggi dan berat badan. Pengambilan data dilakukan dengan wawancara dan pemeriksaan fisik. Pilot dikategorikan memiliki kebiasaan latihan fisik sesuai rekomendasi ACSM apabila melakukan latihan fisik dengan intensitas sedang selama 150 menit per minggu atau latihan fisik dengan intensitas berat selama 75 menit per minggu. Hasil Jam terbang 7 hari terakhir merupakan faktor dominan terhadap kebiasaan latihan fisik. Jika dibandingkan dengan pilot dengan jam terbang 7 hari terakhir < 3,5 jam, maka pilot dengan jam terbang 7 hari terakhir 3,5-14 jam berisiko 24% lebih rendah memiliki kebiasaan latihan fisik sesuai [RRa= 0,76; p=0,032]. Simpulan Faktor risiko yang berpengaruh terhadap kebiasaan latihan fisik adalah jam terbang 7 hari terakhir. Kata kunci: Jam terbang 7 hari terakhir, kebiasaan latihan fisik, pilot sipil Indonesia  Background The most frequently reported barrier of doing physical exercise in developed countries is lack of time. Based on the Civil Aviation Safety Regulation part 121, the maximum working hour for commercial pilot in 7 consecutive days is 30 hours. The study objective is to identify the relation between flight hours in 7 consecutive days and the physical exercise habit among the civil pilots in

  15. Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children

    International Nuclear Information System (INIS)

    Olivieri, Laura; O'Brien, Kendall J.; Cross, Russell; Xue, Hui; Kellman, Peter; Hansen, Michael S.

    2016-01-01

    The value of late-gadolinium-enhancement (LGE) imaging in the diagnosis and management of pediatric and congenital heart disease is clear; however current acquisition techniques are susceptible to error and artifacts when performed in children because of children's higher heart rates, higher prevalence of sinus arrhythmia, and inability to breath-hold. Commonly used techniques in pediatric LGE imaging include breath-held segmented FLASH (segFLASH) and steady-state free precession-based (segSSFP) imaging. More recently, single-shot SSFP techniques with respiratory motion-corrected averaging have emerged. This study tested and compared single-shot free-breathing LGE techniques with standard segmented breath-held techniques in children undergoing LGE imaging. Thirty-two consecutive children underwent clinically indicated late-enhancement imaging using intravenous gadobutrol 0.15 mmol/kg. Breath-held segSSFP, breath-held segFLASH, and free-breathing single-shot SSFP LGE sequences were performed in consecutive series in each child. Two blinded reviewers evaluated the quality of the images and rated them on a scale of 1-5 (1 = poor, 5 = superior) based on blood pool-myocardial definition, presence of cardiac motion, presence of respiratory motion artifacts, and image acquisition artifact. We used analysis of variance (ANOVA) to compare groups. Patients ranged in age from 9 months to 18 years, with a mean +/- standard deviation (SD) of 13.3 +/- 4.8 years. R-R interval at the time of acquisition ranged 366-1,265 milliseconds (ms) (47-164 beats per minute [bpm]), mean +/- SD of 843+/-231 ms (72+/-21 bpm). Mean +/- SD quality ratings for long-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.1+/-0.9, 3.4+/-0.9 and 4.0+/-0.9, respectively (P < 0.01 by ANOVA). Mean +/- SD quality ratings for short-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.4+/-1, 3.8+/-0.9 and 4.3+/-0.7, respectively (P < 0.01 by ANOVA). Single-shot late

  16. Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children

    Energy Technology Data Exchange (ETDEWEB)

    Olivieri, Laura; O' Brien, Kendall J. [Children' s National Health System, Division of Cardiology, Washington, DC (United States); National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD (United States); Cross, Russell [Children' s National Health System, Division of Cardiology, Washington, DC (United States); Xue, Hui; Kellman, Peter; Hansen, Michael S. [National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD (United States)

    2016-06-15

    The value of late-gadolinium-enhancement (LGE) imaging in the diagnosis and management of pediatric and congenital heart disease is clear; however current acquisition techniques are susceptible to error and artifacts when performed in children because of children's higher heart rates, higher prevalence of sinus arrhythmia, and inability to breath-hold. Commonly used techniques in pediatric LGE imaging include breath-held segmented FLASH (segFLASH) and steady-state free precession-based (segSSFP) imaging. More recently, single-shot SSFP techniques with respiratory motion-corrected averaging have emerged. This study tested and compared single-shot free-breathing LGE techniques with standard segmented breath-held techniques in children undergoing LGE imaging. Thirty-two consecutive children underwent clinically indicated late-enhancement imaging using intravenous gadobutrol 0.15 mmol/kg. Breath-held segSSFP, breath-held segFLASH, and free-breathing single-shot SSFP LGE sequences were performed in consecutive series in each child. Two blinded reviewers evaluated the quality of the images and rated them on a scale of 1-5 (1 = poor, 5 = superior) based on blood pool-myocardial definition, presence of cardiac motion, presence of respiratory motion artifacts, and image acquisition artifact. We used analysis of variance (ANOVA) to compare groups. Patients ranged in age from 9 months to 18 years, with a mean +/- standard deviation (SD) of 13.3 +/- 4.8 years. R-R interval at the time of acquisition ranged 366-1,265 milliseconds (ms) (47-164 beats per minute [bpm]), mean +/- SD of 843+/-231 ms (72+/-21 bpm). Mean +/- SD quality ratings for long-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.1+/-0.9, 3.4+/-0.9 and 4.0+/-0.9, respectively (P < 0.01 by ANOVA). Mean +/- SD quality ratings for short-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.4+/-1, 3.8+/-0.9 and 4.3+/-0.7, respectively (P < 0.01 by ANOVA). Single-shot late

  17. Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging

    DEFF Research Database (Denmark)

    Enevoldsen, Lotte H; Menashi, Changez A K; Andersen, Ulrik B

    2013-01-01

    time (HT) protocols and Evolution for Cardiac Software. METHODS: We studied 45 consecutive, non-selected patients referred for a clinically indicated routine 2-day stress/rest (99m)Tc-Sestamibi myocardial perfusion SPECT. All patients underwent an FT and an HT scan. Both FT and HT scans were processed......-RR) and for quantitative analysis (FT-FBP, HT-FBP, and HT-RR). The datasets were analyzed using commercially available QGS/QPS software and read by two observers evaluating image quality and clinical interpretation. Image quality was assessed on a 10-cm visual analog scale score. RESULTS: HT imaging was associated......: Use of RR reconstruction algorithms compensates for loss of image quality associated with reduced scan time. Both HT acquisition and RR reconstruction algorithm had significant effects on motion and perfusion parameters obtained with standard software, but these effects were relatively small...

  18. Spectrum of perforation peritonitis in India-review of 504 consecutive cases

    OpenAIRE

    Jhobta, Rajender Singh; Attri, Ashok Kumar; Kaushik, Robin; Sharma, Rajeev; Jhobta, Anupam

    2006-01-01

    Abstract Background/objective Perforation peritonitis is the most common surgical emergency in India. The spectrum of etiology of perforation in Tropical countries continues to be different from its Western counterpart. The objective of the study was to highlight the spectrum of perforation peritonitis as encountered by us at Government Medical College and Hospital (GMCH), Chandigarh. Methods Five hundred and four consecutive cases of perforation peritonitis over a period of five years were r...

  19. Epidemiology of Pediatric Convulsive Status Epilepticus With Fever in the Emergency Department: A Cohort Study of 381 Consecutive Cases.

    Science.gov (United States)

    Hayakawa, Itaru; Miyama, Sahoko; Inoue, Nobuaki; Sakakibara, Hiroshi; Hataya, Hiroshi; Terakawa, Toshiro

    2016-09-01

    Pediatric convulsive status epilepticus with fever is common in the emergency setting but leads to severe neurological sequelae in some patients. To explore the epidemiology of convulsive status epilepticus with fever, a retrospective cohort covering all convulsive status epilepticus cases with fever seen in the emergency department of a tertiary care children's hospital were consecutively collected. Of the 381 consecutive cases gathered, 81.6% were due to prolonged febrile seizure, 6.6% to encephalopathy/encephalitis, 0.8% to meningitis, and 7.6% to epilepsy. In addition, seizures were significantly longer in encephalopathy/encephalitis cases than in prolonged febrile seizure cases (log rank test, P status epilepticus with fever in the emergency setting, and will help optimize the management of pediatric patients presenting to the emergency department with convulsive status epilepticus with fever. © The Author(s) 2016.

  20. Postoperative imaging of the shoulder

    International Nuclear Information System (INIS)

    Woertler, K.; Rummeny, E.J.

    2004-01-01

    Correct interpretation of imaging findings in the postoperative shoulder is impaired by surgical distortion of normal anatomy and possible artifacts. Advanced postoperative imaging of the shoulder in addition to the selection of the best suited modality necessitates familiarity with the surgical procedure that has been performed and its consecutive morphological changes. This article reviews the most common arthroscopic and open techniques used for treatment of shoulder instability, lesions of the superior labral-bicipital complex, primery impingement, and rotator cuff tears, their typical postoperative imaging findings, as well as the diagnostic performance of cross sectional imaging techniques in the detection of recurrent lesions and complications. (orig.) [de

  1. Diffusion-weighted imaging in acute demyelinating myelopathy

    International Nuclear Information System (INIS)

    Zecca, Chiara; Cereda, Carlo; Tschuor, Silvia; Staedler, Claudio; Nadarajah, Navarajah; Bassetti, Claudio L.; Gobbi, Claudio; Wetzel, Stephan; Santini, Francesco

    2012-01-01

    Diffusion-weighted imaging (DWI) has become a reference MRI technique for the evaluation of neurological disorders. Few publications have investigated the application of DWI for inflammatory demyelinating lesions. The purpose of the study was to describe diffusion-weighted imaging characteristics of acute, spinal demyelinating lesions. Six consecutive patients (two males, four females; aged 28-64 years) with acute spinal cord demyelinating lesions were studied in a prospective case series design from June 2009 to October 2010. We performed magnetic resonance imaging studies from 2 to 14 days from symptom onset on the patients with relapsing remitting multiple sclerosis (n = 3) or clinically isolated syndrome (n = 3). Main outcome measures were diffusion-weighted imaging and apparent diffusion coefficient pattern (ADC) of acute spinal cord demyelinating lesions. All spinal lesions showed a restricted diffusion pattern (DWI+/ADC-) with a 24% median ADC signal decrease. A good correlation between clinical presentation and lesion site was observed. Acute demyelinating spinal cord lesions show a uniform restricted diffusion pattern. Clinicians and neuro-radiologists should be aware that this pattern is not necessarily confirmatory for an ischaemic aetiology. (orig.)

  2. Diffusion-weighted imaging in acute demyelinating myelopathy

    Energy Technology Data Exchange (ETDEWEB)

    Zecca, Chiara; Cereda, Carlo; Tschuor, Silvia; Staedler, Claudio; Nadarajah, Navarajah; Bassetti, Claudio L.; Gobbi, Claudio [Ospedale Regionale di Lugano, Servizio di Neurologia e Neuroradiologia, Neurocenter of Southern Switzerland, Lugano (Switzerland); Wetzel, Stephan [Swiss Neuro Institute (SNI), Abteilung fuer Neuroradiologie, Hirslanden Klinik Zuerich, Zuerich (Switzerland); Santini, Francesco [University of Basel Hospital, Division of Radiological Physics, Basel (Switzerland)

    2012-06-15

    Diffusion-weighted imaging (DWI) has become a reference MRI technique for the evaluation of neurological disorders. Few publications have investigated the application of DWI for inflammatory demyelinating lesions. The purpose of the study was to describe diffusion-weighted imaging characteristics of acute, spinal demyelinating lesions. Six consecutive patients (two males, four females; aged 28-64 years) with acute spinal cord demyelinating lesions were studied in a prospective case series design from June 2009 to October 2010. We performed magnetic resonance imaging studies from 2 to 14 days from symptom onset on the patients with relapsing remitting multiple sclerosis (n = 3) or clinically isolated syndrome (n = 3). Main outcome measures were diffusion-weighted imaging and apparent diffusion coefficient pattern (ADC) of acute spinal cord demyelinating lesions. All spinal lesions showed a restricted diffusion pattern (DWI+/ADC-) with a 24% median ADC signal decrease. A good correlation between clinical presentation and lesion site was observed. Acute demyelinating spinal cord lesions show a uniform restricted diffusion pattern. Clinicians and neuro-radiologists should be aware that this pattern is not necessarily confirmatory for an ischaemic aetiology. (orig.)

  3. Are undesirable contact kinematics minimized after kinematically aligned total knee arthroplasty? An intersurgeon analysis of consecutive patients.

    Science.gov (United States)

    Howell, Stephen M; Hodapp, Esther E; Vernace, Joseph V; Hull, Maury L; Meade, Thomas D

    2013-10-01

    Tibiofemoral contact kinematics or knee implant motions have a direct influence on patient function and implant longevity and should be evaluated for any new alignment technique such as kinematically aligned total knee arthroplasty (TKA). Edge loading of the tibial liner and external rotation (reverse of normal) and adduction of the tibial component on the femoral component are undesirable contact kinematics that should be minimized. Accordingly, this study determined whether the overall prevalence of undesirable contact kinematics during standing, mid kneeling near 90 degrees and full kneeling with kinematically aligned TKA are minimal and not different between groups of consecutive patients treated by different surgeons. Three surgeons were asked to perform cemented, kinematically aligned TKA with patient-specific guides in a consecutive series of patients with their preferred cruciate-retaining (CR) implant. In vivo tibiofemoral contact positions were obtained using a 3- to 2-dimensional image registration technique in 69 subjects (Vanguard CR-TKA N = 22, and Triathlon CR-TKA N = 47). Anterior or posterior edge loading of the tibial liner was not observed. The overall prevalence of external rotation of the tibial component on the femoral component of 6 % was low and not different between surgeons (n.s.). The overall prevalence of adduction of the tibial component on the femoral component of 4 % was low and not different between surgeons (n.s.). Kinematically aligned TKA minimized the undesirable contact kinematics of edge loading of the tibial liner, and external rotation and adduction of the tibial component on the femoral component during standing and kneeling, which suggests an optimistic prognosis for durable long-term function. III.

  4. Organizational Factors and Long-Term Mortality after Hip Fracture Surgery. A Cohort Study of 6143 Consecutive Patients Undergoing Hip Fracture Surgery

    DEFF Research Database (Denmark)

    Lund, Caterina A; Møller, Ann M; Wetterslev, Jørn

    2014-01-01

    OBJECTIVE: In hospital and health care organizational factors may be changed to reduce postoperative mortality. The aim of this study is to evaluate a possible association between mortality and 'length of hospital stay', 'priority of surgery', 'time of surgery', or 'surgical delay' in hip fracture...... surgery. DESIGN: Observational cohort study. SETTING: Prospectively and consecutively reported data from the Danish Anaesthesia Database were linked to The Danish National Registry of Patients and The Civil Registration System. Records on vital status, admittance, discharges, codes of diagnosis......; therefore cluster randomized clinical trials comparing different clinical set ups may be warranted evaluating health care organizational factors....

  5. Interset stretching does not influence the kinematic profile of consecutive bench-press sets.

    Science.gov (United States)

    García-López, David; Izquierdo, Mikel; Rodríguez, Sergio; González-Calvo, Gustavo; Sainz, Nuria; Abadía, Olaia; Herrero, Azael J

    2010-05-01

    This study was undertaken to examine the role of interset stretching on the time course of acceleration portion AP and mean velocity profile during the concentric phase of 2 bench-press sets with a submaximal load (60% of the 1 repetition maximum). Twenty-five college students carried out, in 3 different days, 2 consecutive bench-press sets leading to failure, performing between sets static stretching, ballistic stretching, or no stretching. Acceleration portion and lifting velocity patterns of the concentric phase were not altered during the second set, regardless of the stretching treatment performed. However, when velocity was expressed in absolute terms, static stretching reduced significantly (p velocity during the second set compared to the first one. Therefore, if maintenance of a high absolute velocity over consecutive sets is important for training-related adaptations, static stretching should be avoided or replaced by ballistic stretching.

  6. Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis.

    Science.gov (United States)

    Cornfeld, Daniel; Israel, Gary; Detroy, Ezra; Bokhari, Jamal; Mojibian, Hamid

    2011-03-01

    The purpose of the study was to quantify the radiation dose reduction achieved when imaging the aorta using Adaptive Statistical Iterative Reconstruction (ASIR) and to determine if this has an effect on image quality. We retrospectively reviewed 31 CT angiography examinations of the thoracic and abdominal aorta performed with ASIR and 32 consecutive similar examinations performed without ASIR. Volume CT dose index (CTDI(vol)), dose-length product (DLP), aortic enhancement at multiple levels, aorta-to-muscle contrast-to-noise ratio at multiple levels, and subjective image quality were compared between the two groups. The mean CTDI(vol) and DLP were significantly lower for the studies performed with ASIR versus studies without ASIR (15.6 vs 21.5 mGy, with an average difference of 5.8 mGy [95% CI 2.3-9.4 mGy] and 818 vs 1075 mGy × cm with an average difference of -257 mGy × cm [54-460 mGy × cm], respectively). Aortic enhancement, aortic signal-to-noise ratio, and aortic to muscle contrast-to-noise ratio were not different between the two groups. Subjectively, one reviewer preferred the non-ASIR images and one found the images equivalent. Both reviewers believed the images were of diagnostic quality. A 29% decrease in CTDI(vol) and a 20% decrease in DLP were obtained in scans with ASIR compared with scans without ASIR, without a quantitative loss of image quality.

  7. Observation of a cavitation cloud in tissue using correlation between ultrafast ultrasound images.

    Science.gov (United States)

    Prieur, Fabrice; Zorgani, Ali; Catheline, Stefan; Souchon, Rémi; Mestas, Jean-Louis; Lafond, Maxime; Lafon, Cyril

    2015-07-01

    The local application of ultrasound is known to improve drug intake by tumors. Cavitating bubbles are one of the contributing effects. A setup in which two ultrasound transducers are placed confocally is used to generate cavitation in ex vivo tissue. As the transducers emit a series of short excitation bursts, the evolution of the cavitation activity is monitored using an ultrafast ultrasound imaging system. The frame rate of the system is several thousands of images per second, which provides several tens of images between consecutive excitation bursts. Using the correlation between consecutive images for speckle tracking, a decorrelation of the imaging signal appears due to the creation, fast movement, and dissolution of the bubbles in the cavitation cloud. By analyzing this area of decorrelation, the cavitation cloud can be localized and the spatial extent of the cavitation activity characterized.

  8. Acupuncture of Weizhong (BL 40) and Zusanli (ST 36) on the study of brain function by PET/CT imaging

    International Nuclear Information System (INIS)

    Shao Guangrui; Chen Ying; Yan Bin; Liu Cheng; Wang Guangcai; Tan Qiwen

    2006-01-01

    Objective: To explore the correlation between acupuncture of the points and certain functional areas of brain by PET/CT imaging. Methods: Twelve healthy volunteers were acupunctured separately in the point Weizhong (BL 40, right leg) and Zusanli(ST 36, right leg), and 5 consecutive PET/CT images were taken, statistical parameter map (SPM) paired t-test was analyzed between the different activated brain PET/CT imagings. Results: Changes of PET/CT imaging were found in acupuncture of the point Weizhong (BL 40) and Zusanli(ST 36) in 12 healthy volunteers. High metabolic areas were demonstrated in multiple brain regions, the data of two groups had significant difference between 2 points (t>4.03, P< 0.01). Conclusion: Acupuncturing the different point resulted activation of the glucose metabolism in different brain areas. (authors)

  9. Relationship between consecutive deterioration of mean deviation value and progression of visual field defect in open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Naito T

    2015-11-01

    Full Text Available Tomoko Naito,1 Keiji Yoshikawa,2 Shiro Mizoue,3 Mami Nanno,4 Tairo Kimura,5 Hirotaka Suzumura,6 Ryuji Takeda,7 Fumio Shiraga1 1Department of Ophthalmology, Okayama University Graduate School of Medicine, Okayama, 2Yoshikawa Eye Clinic, Tokyo, 3Department of Ophthalmology, Ehime University Graduate School of Medicine, Ehime, 4Kagurazaka Minamino Eye Clinic, 5Ueno Eye Clinic, 6Suzumura Eye Clinic, Tokyo, 7Department of Agriculture, Kinki University, Nara, Japan Purpose: To analyze the relationship between consecutive deterioration of mean deviation (MD value and glaucomatous visual field (VF progression in open-angle glaucoma (OAG, including primary OAG and normal tension glaucoma.Patients and methods: The subjects of the study were patients undergoing treatment for OAG who had performed VF tests at least 10 times with a Humphrey field analyzer (SITA standard, C30-2 program. The VF progression was defined by a significantly negative MD slope (MD slope worsening at the final VF test during the follow-up period. The relationship between the MD slope worsening and the consecutive deterioration of MD value were retrospectively analyzed.Results: A total of 165 eyes of 165 patients were included in the analysis. Significant progression of VF defects was observed in 72 eyes of 72 patients (43.6%, while no significant progression was evident in 93 eyes of 93 patients (56.4%. There was significant relationship between the frequency of consecutive deterioration of MD value and MD slope worsening (P<0.0001, Cochran–Armitage trend test. A significant association was observed for MD slope worsening in the eyes with three (odds ratio: 2.1, P=0.0224 and four (odds ratio: 3.6, P=0.0008 consecutive deterioration of MD value in multiple logistic regression analysis, but no significant association in the eyes with two consecutive deterioration (odds ratio: 1.1, P=0.8282. The eyes with VF progression had significantly lower intraocular pressure reduction rate (P<0

  10. Consecutive Short-Scan CT for Geological Structure Analog Models with Large Size on In-Situ Stage.

    Science.gov (United States)

    Yang, Min; Zhang, Wen; Wu, Xiaojun; Wei, Dongtao; Zhao, Yixin; Zhao, Gang; Han, Xu; Zhang, Shunli

    2016-01-01

    For the analysis of interior geometry and property changes of a large-sized analog model during a loading or other medium (water or oil) injection process with a non-destructive way, a consecutive X-ray computed tomography (XCT) short-scan method is developed to realize an in-situ tomography imaging. With this method, the X-ray tube and detector rotate 270° around the center of the guide rail synchronously by switching positive and negative directions alternately on the way of translation until all the needed cross-sectional slices are obtained. Compared with traditional industrial XCTs, this method well solves the winding problems of high voltage cables and oil cooling service pipes during the course of rotation, also promotes the convenience of the installation of high voltage generator and cooling system. Furthermore, hardware costs are also significantly decreased. This kind of scanner has higher spatial resolution and penetrating ability than medical XCTs. To obtain an effective sinogram which matches rotation angles accurately, a structural similarity based method is applied to elimination of invalid projection data which do not contribute to the image reconstruction. Finally, on the basis of geometrical symmetry property of fan-beam CT scanning, a whole sinogram filling a full 360° range is produced and a standard filtered back-projection (FBP) algorithm is performed to reconstruct artifacts-free images.

  11. Asymptotics of Multivariate Regression with Consecutively Added Dependent Varibles

    NARCIS (Netherlands)

    Raats, V.M.; van der Genugten, B.B.; Moors, J.J.A.

    2004-01-01

    We consider multivariate regression where new dependent variables are consecutively added during the experiment (or in time).So, viewed at the end of the experiment, the number of observations decreases with each added variable. The explanatory variables are observed throughout.In a previous paper

  12. Synthesis and Consecutive Reactions of α-Azido Ketones: A Review

    Directory of Open Access Journals (Sweden)

    Sadia Faiz

    2015-08-01

    Full Text Available This review paper covers the major synthetic approaches attempted towards the synthesis of α-azido ketones, as well as the synthetic applications/consecutive reactions of α-azido ketones.

  13. Image registration in gastric emptying studies

    International Nuclear Information System (INIS)

    Shuter, B.; Cooper, R.G.

    1998-01-01

    Full text: We have previously shown that image registration, based upon a two-dimensional cross-correlation (CC) of logarithmic Laplacian images (LLI), corrected motion in biliary studies in up to 90% of cases with minimal artifact. We have now applied the same technique to gastric emptying studies (GES). GES were acquired on an LFOV gamma camera over a two-hour period as 20-26 pairs of anterior-posterior frames (30 second duration and 64 x 64 matrix) for both solid and liquid components. All images were manually registered so that the solid contents of the stomach lay within an operator-drawn ROI. The anterior images of the solid component for 30 randomly selected patients were subjected to further image registration using CC of LLI, CC of raw images (Rl) (a common approach to image registration) and CC of Laplacian images (Ll). All images were aligned to the third image of the study, on which an ROI was drawn to outline the stomach. The number of images in which stomach counts appeared outside this ROI were tallied, in the original and all re-registered studies. Maximum displacements in X/Y position between images of studies registered by the LLI and Rl methods were also computed to directly compare positional accuracy. Stomachs partially exceeded the limits of the ROI in 27, 9, 53 and 54 frames (total of 710) in the original, LLI, Rl and Ll studies respectively. There were 4, 1, 6 and 7 studies with misregistered stomachs on more than 2 frames. Frames in seven Rl studies differed from the LLI studies in ) X/Y position by 3 pixels or more. Cross-correlation using LLI was the only method which improved upon the original manual registration. The Rl and Ll methods increased the number of misregistered frames. We conclude that in gastric emptying studies, as in biliary studies, object tracking by CC of LLI is the method of choice for image registration

  14. Changes in the diurnal rhythms of cortisol, melatonin, and testosterone after 2, 4, and 7 consecutive night shifts in male police officers

    DEFF Research Database (Denmark)

    Jensen, Marie Aarrebo; Hansen, Åse Marie; Kristiansen, Jesper

    2016-01-01

    Night work is associated with a large range of acute health problems and possibly also health consequences in the long run. Yet, only very few field studies specifically investigate the effects of consecutive night shift on key physiological regulatory systems. In this field study, we investigated...... the effects of consecutive night shifts on three hormones, melatonin, cortisol, and testosterone, among police officers at work. More specifically, the aim was to investigate how the diurnal rhythms of melatonin, cortisol, and testosterone responded to two, four, and seven consecutive night shifts...... 4th hour when awake. The diurnal rhythms of melatonin, cortisol, and testosterone were all affected differently by an increasing number of consecutive night shifts: the amplitude of the melatonin rhythm was suppressed by 4.9% per day (95% CI 1.4–8.2% per day; p = 0.006). The diurnal rhythm...

  15. Vascular complications following 1500 consecutive living and cadaveric donor renal transplantations: A single center study

    International Nuclear Information System (INIS)

    Salehipour, Mehdi; Salahi, Heshmatollah; Jalaeian, Hamed; Bahador, Ali; Nikeghbalian, Saman; Barzideh, Ehsan; Ariafar, Ali; Malek-Hosseini, Seyed Ali

    2009-01-01

    The aim of this study was to document vascular complications that occurred following cadaveric and living donor kidney transplants in order to assess the overall incidence of these complications at our center as well as to identify possible risk factors. In a retrospective cohort study, 1500 consecutive renal transplant recipients who received a living or cadaveric donor kidney between December 1988 and July 2006 were evaluated. The study was performed at the Nemazee Hospital, Shiraz, Iran. The assessment of the anatomy and number of renal arteries as well as the incidence of vascular complications was made by color doppler ultrasonography, angiography, and/or surgical exploration. Clinically apparent vascular complications were seen in 8.86% of all study patients (n = 133) with the most frequent being hemorrhage (n = 91; 6.1%) followed by allograft renal artery stenosis (n = 26; 1.7%), renal artery thrombosis (n = 9; 0.6%), and renal vein thrombosis (n = 7; 0.5%). Vascular complications were more frequent in recipients of cadaveric organs than recipients of allografts from living donors (12.5% vs. 7.97%; P0.017). The occurrence of vascular complications was significantly more frequent among recipients of renal allografts with multiple arteries when compared with recipients of kidneys with single artery (12.3% vs. 8.2%; P0.033). The same was true to venous complications as well (25.4% vs. 8.2%; P< 0.001). Our study shows that vascular complications were more frequent in allografts with multiple renal blood vessels. Also, the complications were much less frequent in recipients of living donor transplants. (author)

  16. Normal dynamic deformation characteristics of non-consecutive jointed rock masses under impact loads

    Science.gov (United States)

    Zeng, Sheng; Jiang, Bowei; Sun, Bing

    2017-08-01

    In order to study deformation characteristics of non-consecutive single jointed rock masses under impact loads, we used the cement mortar materials to make simulative jointed rock mass samples, and tested the samples under impact loads by the drop hammer. Through analyzing the time-history signal of the force and the displacement, first we find that the dynamic compression displacement of the jointed rock mass is significantly larger than that of the intact jointless rock mass, the compression displacement is positively correlated with the joint length and the impact height. Secondly, the vertical compressive displacement of the jointed rock mass is mainly due to the closure of opening joints under small impact loads. Finally, the peak intensity of the intact rock mass is larger than that of the non-consecutive jointed rock mass and negatively correlated with the joint length under the same impact energy.

  17. Spectrum of histological lesions in 185 consecutive prostatic specimens.

    Directory of Open Access Journals (Sweden)

    Mittal B

    1989-07-01

    Full Text Available One hundred and eighty five consecutive prostate specimens were studied. The predominant lesion noted was benign prostatic hyperplasia (B.P.H. (92.97%. The incidence of carcinoma was low, (7.02%. Conditions which can mimic and should be considered in the differential diagnosis of carcinoma, like basal cell hyperplasia, atypical hyperplasia and atrophy associated hyperplasia were noted in 10, 4 and 3 cases of B.P.H. respectively. None of these cases showed evidence of carcinoma. Corpora amylacea were noted in 38.91% of the cases of B.P.H. and were conspicuously absent in cases of carcinoma. Chronic prostatitis was frequently encountered (58% and metaplastic changes were seen in 11% of the cases.

  18. Consecutive emamectin benzoate and deltamethrin treatments affect the expressions and activities of detoxification enzymes in the rainbow trout (Oncorhynchus mykiss).

    Science.gov (United States)

    Cárcamo, Juan Guillermo; Aguilar, Marcelo N; Carreño, Constanza F; Vera, Tamara; Arias-Darraz, Luis; Figueroa, Jaime E; Romero, Alex P; Alvarez, Marco; Yañez, Alejandro J

    2017-01-01

    Rainbow trout (Oncorhynchus mykiss) subjected to three consecutive, alternating treatments with emamectin benzoate (EMB) and deltamethrin (DM) during outbreaks of Caligus rogercresseyi in a farm located in southern Chile (Hornopiren, Chiloé), were studied to determine the effects of these treatments on the protein and enzymatic activity levels of cytochrome P450 1A (CYP1A), flavin-containing monooxygenase (FMO) and glutathione S-transferase (GST) in different tissues. Consecutive and alternating EMB/DM treatments resulted in a 10-fold increase and 3-fold decrease of CYP1A protein levels in the intestine and gills, respectively. Notably, CYP1A activity levels decreased in most of the analyzed tissues. FMO protein and activity levels markedly increased in the kidney and the intestine. GST was up-regulated in all tissues, either as protein or enzyme activity. When comparing consecutive EMB/DM treatments against previous studies of EMB treatment alone, CYP1A activity levels were similarly diminished, except in muscle. Likewise, FMO activity levels were increased in most of the analyzed tissues, particularly in the muscle, kidney, and intestine. The increases observed for GST were essentially unchanged between consecutive EMB/DM and EMB only treatments. These results indicate that consecutive EMB/DM treatments in rainbow trout induce the expression and activity of FMO and GST enzymes and decrease CYP1A activity. These altered activities of detoxification enzymes could generate imbalances in metabolic processes, synthesis, degradation of hormones and complications associated with drug interactions. It is especially important when analyzing possible effects of consecutive antiparasitic treatments on withholding periods and salmon farming yields. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Imaging patellar complications after knee arthroplasty

    International Nuclear Information System (INIS)

    Melloni, Pietro; Valls, Rafael; Veintemillas, Maite

    2008-01-01

    The purpose of this study is to describe complications affecting the patella in patients with total or partial knee arthroplasty. We respectively analysed plain-film radiographs, as well as ultrasound images when acquired, in a consecutive series of 1272 patients. The mean interval from knee replacement to patellar complications was 5 years and 7 months (range, 5 months to 14 years). The complications described include fracture, instability, dislocation or luxation, necrosis of the patella, infection of the patella, erosion of the patella, patellar impingement on the prosthesis and patellar or quadricipital tendon tear. We discuss the pathological imaging findings in the patella and their differential diagnosis after knee arthroplasty. Patellar complications after knee arthroplasty are uncommon but often potentially serious

  20. Imaging patellar complications after knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Melloni, Pietro [Unitat de Imatge d' Alta Tecnologia, Centre Diagnostic, Corporacio Parc Tauli, Universitat Autonoma de Barcelona, Sabadell (Barcelona) (Spain)], E-mail: pmelloni@cspt.es; Valls, Rafael; Veintemillas, Maite [Unitat de Imatge d' Alta Tecnologia, Centre Diagnostic, Corporacio Parc Tauli, Universitat Autonoma de Barcelona, Sabadell (Barcelona) (Spain)

    2008-03-15

    The purpose of this study is to describe complications affecting the patella in patients with total or partial knee arthroplasty. We respectively analysed plain-film radiographs, as well as ultrasound images when acquired, in a consecutive series of 1272 patients. The mean interval from knee replacement to patellar complications was 5 years and 7 months (range, 5 months to 14 years). The complications described include fracture, instability, dislocation or luxation, necrosis of the patella, infection of the patella, erosion of the patella, patellar impingement on the prosthesis and patellar or quadricipital tendon tear. We discuss the pathological imaging findings in the patella and their differential diagnosis after knee arthroplasty. Patellar complications after knee arthroplasty are uncommon but often potentially serious.

  1. Biologically inspired EM image alignment and neural reconstruction.

    Science.gov (United States)

    Knowles-Barley, Seymour; Butcher, Nancy J; Meinertzhagen, Ian A; Armstrong, J Douglas

    2011-08-15

    Three-dimensional reconstruction of consecutive serial-section transmission electron microscopy (ssTEM) images of neural tissue currently requires many hours of manual tracing and annotation. Several computational techniques have already been applied to ssTEM images to facilitate 3D reconstruction and ease this burden. Here, we present an alternative computational approach for ssTEM image analysis. We have used biologically inspired receptive fields as a basis for a ridge detection algorithm to identify cell membranes, synaptic contacts and mitochondria. Detected line segments are used to improve alignment between consecutive images and we have joined small segments of membrane into cell surfaces using a dynamic programming algorithm similar to the Needleman-Wunsch and Smith-Waterman DNA sequence alignment procedures. A shortest path-based approach has been used to close edges and achieve image segmentation. Partial reconstructions were automatically generated and used as a basis for semi-automatic reconstruction of neural tissue. The accuracy of partial reconstructions was evaluated and 96% of membrane could be identified at the cost of 13% false positive detections. An open-source reference implementation is available in the Supplementary information. seymour.kb@ed.ac.uk; douglas.armstrong@ed.ac.uk Supplementary data are available at Bioinformatics online.

  2. On the relationships between DSM-5 dysfunctional personality traits and social cognition deficits: A study in a sample of consecutively admitted Italian psychotherapy patients.

    Science.gov (United States)

    Fossati, Andrea; Somma, Antonella; Krueger, Robert F; Markon, Kristian E; Borroni, Serena

    2017-11-01

    This study aims at testing the hypothesis that the Diagnostic and Statistical Manual of Mental Disorders fifth edition (DSM-5) alternative model of personality disorder (AMPD) traits may be significantly associated with deficits on 2 different social cognition tasks, namely, the Reading the Mind in the Eyes Test and the Movie for the Assessment of Social Cognition, in a sample of consecutively admitted inpatients and outpatients. The sample was composed of 181 consecutively admitted participants (57.5% women; mean age = 38.58 years). Correlation coefficients and partial correlation coefficients were computed in order to assess the associations among social cognition tasks, DSM-5 AMPD traits, and dimensionally assessed DSM-5 Section II personality disorders. Specific maladaptive traits listed in the DSM-5 AMPD were significantly associated with Reading the Mind in the Eyes Test scores and Movie for the Assessment of Social Cognition scores, even when the effect of selected DSM-5 Section II personality disorders was controlled for. Our results support the relevance of studying social cognitive functioning in subjects suffering from personality disorders. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Analysis of Dietary Intake during Consecutive-Day Chemotherapy for Bone and Soft-Tissue Sarcomas

    Directory of Open Access Journals (Sweden)

    Yuta Hori

    2018-01-01

    Full Text Available BackgroundBone and soft tissue sarcomas are commonly treated with consecutive-day chemotherapy regimens consisting of multiple anticancer agents. Chemotherapy-induced nausea and vomiting (CINV is a serious adverse effect of these regimens and may result in decreased energy intake during chemotherapy. Decreased energy intake may lead to undernutrition and may cause adverse effects on patient quality of life and survival.MethodsPatients with bone and soft tissue sarcomas who received consecutive-day chemotherapy were retrospectively evaluated. CINV and dietary energy intake were assessed, as well as the occurrences of hiccups and constipation during chemotherapy.ResultsA total of 13 patients, 10 males and 3 females, with a total 16 chemotherapy courses were included in the study. All patients received antiemetic prophylaxis. The CINV control rate, defined as no emesis and no rescue therapy, gradually decreased from chemotherapy day 1 (94% to day 5 (75%. Four patients experienced emesis, two of whom had been treated with a cisplatin-containing regimen. Decreased dietary energy intake was possibly associated with CINV during chemotherapy. Anorexia was grade 2 except for one case of grade 3. The incidences of hiccups and constipation were high on days 3–5.ConclusionAntiemetic prophylaxis treatment did not prevent emesis due to consecutive-day chemotherapy, especially with cisplatin-containing regimens, in patients with bone and soft-tissue tumors. Dietary energy intake decreased during chemotherapy, and this appeared to be associated with CINV. In addition, the incidence of hiccups and constipation increased during the course of consecutive-day chemotherapy regimens. Although these results are based on a small number of patients, it may be important to observe nutritional status during chemotherapy, as this may reflect a patient’s general condition. Nutritional counseling might be useful in supporting nutritional status in patients undergoing

  4. Fast-gradient-echo variable-flip-angle imaging of the cervical spine

    International Nuclear Information System (INIS)

    Van Dyke, C.W.; Ross, J.S.; Masaryk, T.J.; Tkach, J.; Beale, S.; Hueftle, M.G.; Kaufman, B.; Modic, M.T.

    1987-01-01

    Two hundred consecutive patients were studied with 4-mm sagittal and axial T1-weighted images and gradient echo sequences with 6-msec or 13-msec echo time (TE) and 10 0 or 60 0 flip angles to evaluate cervical extradural disease. Images were independently evaluated for contrast behavior and anatomy, then directly compared for conspicuity of lesions. FLASH sequences produced better conspicuity of disease in half the imaging time. T1-weighted spin-echo (SE) sequences were more sensitive to marrow changes and intradural disease. Shorter TEs produced overall image improvement and reduced susceptibility effects. A fast and sensitive cervical examination combines sagittal T1-weighted SE with sagittal and axial FLASH 10 0 sequences with 6-msec TE

  5. Analysis of soil microbial community structure and enzyme activities associated with negative effects of pseudostellaria heterophylla consecutive monoculture on yield

    International Nuclear Information System (INIS)

    Lin, S.; Lin, W.X.

    2015-01-01

    Pseudostellaria heterophylla is an important medicinal plant in China. However, cultivation of P. heterophylla using consecutive monoculture results in significant reductions in yield and quality. In this study, terminal-restriction fragment length polymorphism (T-RFLP) analysis and measurement of soil enzyme activities were used to investigate the regulation of soil micro-ecology to identify ways to overcome the negative effects of P. heterophylla consecutive monoculture. T-RFLP analysis showed that rice/P. heterophylla (RP) and bean/P. heterophylla (BP) crop rotation systems increased the number and diversity of microbial groups in P. heterophylla rhizosphere soil. In particular, the RP and BP crop rotations increased the number and abundance of beneficial bacterial species compared with two-year consecutive monoculture of P. heterophylla. The presence of these beneficial bacteria was positively correlated with soil enzyme activities which increased in rhizosphere soils of the RP and BP crop rotation systems. The results indicated that crop rotation systems could increase activities of key soil enzymes and beneficial microbial groups and improve soil health. This study could provide a theoretical basis to resolve the problems associated with P. heterophylla consecutive monoculture. (author)

  6. Optimizing imaging in suspected appendicitis (OPTIMAP-study: A multicenter diagnostic accuracy study of MRI in patients with suspected acute appendicitis. Study Protocol

    Directory of Open Access Journals (Sweden)

    Bossuyt Patrick MM

    2010-10-01

    Full Text Available Abstract Background In patients with clinically suspected appendicitis, imaging is needed to substantiate the clinical diagnosis. Imaging accuracy of ultrasonography (US is suboptimal, while the most accurate technique (CT is associated with cancer related deaths through exposure to ionizing radiation. MRI is a potential replacement, without associated ionizing radiation and no need for contrast medium administration. If MRI is proven to be sufficiently accurate, it could be introduced in the diagnostic pathway of patients with suspected appendicitis, increasing diagnostic accuracy and improving clinical outcomes, without the risk of radiation induced cancer or iodinated contrast medium-related drawbacks. The multicenter OPTIMAP study was designed to estimate the diagnostic accuracy of MRI in patients with suspected acute appendicitis in the general population. Methods/Design Eligible for this study are consecutive patients presenting with clinically suspected appendicitis at the emergency department in six centers. All patients will undergo imaging according to the Dutch guideline for acute appendicitis: initial ultrasonography in all and subsequent CT whenever US does not confirm acute appendicitis. Then MRI is performed in all patients, but the results are not used for patient management. A final diagnosis assigned by an expert panel, based on all available information including 3-months follow-up, except MRI findings, is used as the reference standard in estimating accuracy. We will calculate the sensitivity, specificity, predictive values and inter-observer agreement of MRI, and aim to include 230 patients. Patient acceptance and total imaging costs will also be evaluated. Discussion If MRI is found to be sufficiently accurate, it could replace CT in some or all patients. This will limit or obviate the ionizing radiation exposure associated risk of cancer induction and contrast medium induced nephropathy with CT, preventing the burden and

  7. A device for multimodal imaging of skin

    Science.gov (United States)

    Spigulis, Janis; Garancis, Valerijs; Rubins, Uldis; Zaharans, Eriks; Zaharans, Janis; Elste, Liene

    2013-03-01

    A compact prototype device for diagnostic imaging of skin has been developed and tested. Polarized LED light at several spectral regions is used for illumination, and round skin spot of diameter 30mm is imaged by a CMOS sensor via crossoriented polarizing filter. Four consecutive imaging series are performed: (1) RGB image at white LED illumination for revealing subcutaneous structures; (2) four spectral images at narrowband LED illumination (450nm, 540nm, 660nm, 940nm) for mapping of the main skin chromophores; (3) video-imaging under green LED illumination for mapping of skin blood perfusion; (4) autofluorescence video-imaging under UV (365nm) LED irradiation for mapping of the skin fluorophores. Design details of the device as well as preliminary results of clinical tests are presented.

  8. Probability-Based Recognition Framework for Underwater Landmarks Using Sonar Images †.

    Science.gov (United States)

    Lee, Yeongjun; Choi, Jinwoo; Ko, Nak Yong; Choi, Hyun-Taek

    2017-08-24

    This paper proposes a probability-based framework for recognizing underwater landmarks using sonar images. Current recognition methods use a single image, which does not provide reliable results because of weaknesses of the sonar image such as unstable acoustic source, many speckle noises, low resolution images, single channel image, and so on. However, using consecutive sonar images, if the status-i.e., the existence and identity (or name)-of an object is continuously evaluated by a stochastic method, the result of the recognition method is available for calculating the uncertainty, and it is more suitable for various applications. Our proposed framework consists of three steps: (1) candidate selection, (2) continuity evaluation, and (3) Bayesian feature estimation. Two probability methods-particle filtering and Bayesian feature estimation-are used to repeatedly estimate the continuity and feature of objects in consecutive images. Thus, the status of the object is repeatedly predicted and updated by a stochastic method. Furthermore, we develop an artificial landmark to increase detectability by an imaging sonar, which we apply to the characteristics of acoustic waves, such as instability and reflection depending on the roughness of the reflector surface. The proposed method is verified by conducting basin experiments, and the results are presented.

  9. Confabulations after Bilateral Consecutive Strokes of the Lenticulostriate Arteries

    Directory of Open Access Journals (Sweden)

    Antonio Carota

    2012-03-01

    Full Text Available We describe the case of a 75-year-old woman who manifested persistent confabulations after two consecutive strokes encompassing the area of the lenticulostriate arteries territory on both hemispheres. Findings reported on this rare clinical syndrome suggest that fantastic confabulations and delusional thoughts may arise after bilateral damage of subcortical nonthalamic structures.

  10. Potential benefit of a simultaneous, side-by-side display of contrast MDCT and echocardiography over routine sequential imaging for assessment of adult congenital heart disease: A preliminary study.

    Science.gov (United States)

    Oe, Hiroki; Watanabe, Nobuhisa; Miyoshi, Toru; Osawa, Kazuhiro; Akagi, Teiji; Kanazawa, Susumu; Ito, Hiroshi

    2018-06-18

    Management of adult congenital heart disease (ACHD) patients requires understanding of its complex morphology and functional features. An innovative imaging technique has been developed to display a virtual multi-planar reconstruction obtained from contrast-enhanced multidetector-computed tomography (MDCT) corresponding to the same cross-sectional image from transthoracic echocardiography (TTE). The aim of this study is to assess the usefulness of this imaging technology in ACHD patients. This study consisted of 46 consecutive patients (30 women; mean age, 52±18 years old) with ACHD who had undergone contrast MDCT. All patients underwent TTE within a week of MDCT. An experienced sonographer who did not know the results of MDCT conducted a diagnosis using TTE and, then, using the new imaging technology. We studied whether this imaging technology provided additional or unexpected findings or makes more accurate diagnosis. In this imaging technology, MDCT cross-section provides higher-resolution image to the deep compared to corresponding TTE image. Depending on the MDCT section which can be arbitrarily set under the echo guide, we can diagnose unexpected or incremental lesions or more accurately assess the severity of the lesion in 27 patients (59%) compared to TTE study alone. This imaging technology was useful in the following situations: CONCLUSIONS: This integrated imaging technology provides incremental role over TTE in complex anatomy, and allows functional information in ACHD patients. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  11. Imaging findings in children with proliferative disorders following multivisceral transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Hryhorczuk, Anastasia L. [Tufts Medical Center, Department of Radiology, Boston, MA (United States); Kim, Heung Bae [Boston Children' s Hospital, Department of Surgery, Boston, MA (United States); Harris, Marian H.; Vargas, Sara O. [Boston Children' s Hospital, Department of Pathology, Boston, MA (United States); Zurakowski, David [Boston Children' s Hospital, Department of Biostatistics, Boston, MA (United States); Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Departments of Radiology and Medicine, Boston, MA (United States)

    2015-08-15

    Multivisceral transplantation represents an important treatment option for children with intestinal failure. The attendant immunosuppression can lead to a spectrum of cellular proliferations including benign and malignant smooth muscle tumors and lymphoproliferative disorders, many related to cellular dysregulation from Epstein-Barr virus infection. The purpose of this study is to investigate the rates of post-transplantation proliferative disorders among children with multivisceral transplantation and to characterize the imaging and pathological features of these disorders. We identified all consecutive children who underwent multivisceral transplant from August 2004 to October 2011 with at least 27 months of clinical and imaging follow-up. We reviewed medical records to determine the underlying causes of the multivisceral transplant, age at transplantation, onset of neoplasm development, and outcome. Two pediatric radiologists reviewed all imaging studies independently and diagnosis of disease was made by consensus interpretation. Pathological specimens were reviewed for histopathological findings of post-transplantation neoplasm in this pediatric patient population. The study population consisted of 14 consecutive pediatric patients (7 boys and 7 girls; mean age 26 months, range 4-113 months). Of these 14 children, 4 (29%) developed histologically confirmed post-transplant neoplasms at a mean time of 2.4 years after multivisceral transplantation. Types of neoplasms included post-transplant lymphoproliferative disorder (PTLD) in three (21%) and Epstein-Barr-virus-associated smooth muscle tumor in two (14%). (One child developed both neoplasms following transplantation). Both children with smooth muscle tumor associated with Epstein-Barr virus presented with characteristic hypointense solid masses with peripheral rim enhancement on cross-sectional imaging studies. The mortality rate of children who developed post-transplant neoplasms was higher than that of those

  12. Imaging findings in children with proliferative disorders following multivisceral transplantation

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Kim, Heung Bae; Harris, Marian H.; Vargas, Sara O.; Zurakowski, David; Lee, Edward Y.

    2015-01-01

    Multivisceral transplantation represents an important treatment option for children with intestinal failure. The attendant immunosuppression can lead to a spectrum of cellular proliferations including benign and malignant smooth muscle tumors and lymphoproliferative disorders, many related to cellular dysregulation from Epstein-Barr virus infection. The purpose of this study is to investigate the rates of post-transplantation proliferative disorders among children with multivisceral transplantation and to characterize the imaging and pathological features of these disorders. We identified all consecutive children who underwent multivisceral transplant from August 2004 to October 2011 with at least 27 months of clinical and imaging follow-up. We reviewed medical records to determine the underlying causes of the multivisceral transplant, age at transplantation, onset of neoplasm development, and outcome. Two pediatric radiologists reviewed all imaging studies independently and diagnosis of disease was made by consensus interpretation. Pathological specimens were reviewed for histopathological findings of post-transplantation neoplasm in this pediatric patient population. The study population consisted of 14 consecutive pediatric patients (7 boys and 7 girls; mean age 26 months, range 4-113 months). Of these 14 children, 4 (29%) developed histologically confirmed post-transplant neoplasms at a mean time of 2.4 years after multivisceral transplantation. Types of neoplasms included post-transplant lymphoproliferative disorder (PTLD) in three (21%) and Epstein-Barr-virus-associated smooth muscle tumor in two (14%). (One child developed both neoplasms following transplantation). Both children with smooth muscle tumor associated with Epstein-Barr virus presented with characteristic hypointense solid masses with peripheral rim enhancement on cross-sectional imaging studies. The mortality rate of children who developed post-transplant neoplasms was higher than that of those

  13. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough

    OpenAIRE

    Nin, Carlos Shuler; Marchiori, Edson; Irion, Klaus Loureiro; Paludo, Artur de Oliveira; Alves, Giordano Rafael Tronco; Hochhegger, Daniela Reis; Hochhegger, Bruno

    2013-01-01

    OBJECTIVE: To assess the routine use of barium swallow study in patients with chronic cough.METHODS: Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks) were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological...

  14. Behaviors study of image registration algorithms in image guided radiation therapy

    International Nuclear Information System (INIS)

    Zou Lian; Hou Qing

    2008-01-01

    Objective: Study the behaviors of image registration algorithms, and analyze the elements which influence the performance of image registrations. Methods: Pre-known corresponding coordinates were appointed for reference image and moving image, and then the influence of region of interest (ROI) selection, transformation function initial parameters and coupled parameter spaces on registration results were studied with a software platform developed in home. Results: Region of interest selection had a manifest influence on registration performance. An improperly chosen ROI resulted in a bad registration. Transformation function initial parameters selection based on pre-known information could improve the accuracy of image registration. Coupled parameter spaces would enhance the dependence of image registration algorithm on ROI selection. Conclusions: It is necessary for clinic IGRT to obtain a ROI selection strategy (depending on specific commercial software) correlated to tumor sites. Three suggestions for image registration technique developers are automatic selection of the initial parameters of transformation function based on pre-known information, developing specific image registration algorithm for specific image feature, and assembling real-time image registration algorithms according to tumor sites selected by software user. (authors)

  15. Image quality and patient acceptance of four regimens with different amounts of mild laxatives for CT colonography

    NARCIS (Netherlands)

    Jensch, Sebastiaan; de Vries, Ayso H.; Pot, Dennis; Peringa, Jan; Bipat, Shandra; Florie, Jasper; van Gelder, Rogier E.; Stoker, Jaap

    2008-01-01

    OBJECTIVE: The purpose of our study was to prospectively evaluate image quality and patient acceptance of CT colonography (CTC) with fecal tagging using different levels of catharsis. SUBJECTS AND METHODS: Forty consecutive increased-risk patients were randomized. Group 1 received orally 20 mg of

  16. MRI quality control: six imagers studied using eleven unified image quality parameters

    International Nuclear Information System (INIS)

    Ihalainen, T.; Sipilae, O.; Savolainen, S.

    2004-01-01

    Quality control of the magnetic resonance imagers of different vendors in the clinical environment is non-harmonised, and comparing the performance is difficult. The purpose of this study was to develop and apply a harmonised long-term quality control protocol for the six imagers in our organisation in order to assure that they fulfil the same basic image quality requirements. The same Eurospin phantom set and identical imaging parameters were used with each imager. Values of 11 comparable parameters describing the image quality were measured. Automatic image analysis software was developed to objectively analyse the images. The results proved that the imagers were operating at a performance level adequate for clinical imaging. Some deficiencies were detected in image uniformity and geometry. The automated analysis of the Eurospin phantom images was successful. The measurements were successfully repeated after 2 weeks on one imager and after half a year on all imagers. As an objective way of examining the image quality, this kind of comparable and objective quality control of different imagers is considered as an essential step towards harmonisation of the clinical MRI studies through a large hospital organisation. (orig.)

  17. INJURY INCIDENCE IN A SPANISH SUB-ELITE PROFESSIONAL FOOTBALL TEAM: A PROSPECTIVE STUDY DURING FOUR CONSECUTIVE SEASONS

    Directory of Open Access Journals (Sweden)

    Javier Mallo

    2011-12-01

    Full Text Available The aim of this study was to investigate the injury incidence and injury characteristics of a Spanish sub-elite professional football team during four consecutive seasons. A team was followed prospectively from the season 2003-2004 to 2006-2007 and individual player exposure and time loss injuries were recorded during all club training sessions and matches. A total of 313 time-loss injuries were recorded. The mean injury incidence was 10.9 injuries/1000 hours (5.2 injuries/1000 training hours and 44.1 injuries/1000 match hours. The injury incidence during competitive matches was higher (p 28 days absence was 0.4 injuries/1000 hours. The thigh was the most commonly (35% injured region and caused 29% of all competitive match absence. Muscle injuries in the four main groups of the lower limbs (hamstrings, adductors, quadriceps and calf muscles caused 43% of competitive match unavailability. The results of this study show that the risk to sustain a major injury in the course of the season was low for sub- elite footballers in comparison to elite players. Thigh strains were the first cause of absence in competition due to injury.

  18. Imaging yield from 133 consecutive patients with prostate cancer and low trigger PSA from a single institution

    International Nuclear Information System (INIS)

    Shinagare, A.B.; Keraliya, A.; Somarouthu, B.; Tirumani, S.H.; Ramaiya, N.H.; Kantoff, P.W.

    2016-01-01

    Aim: To investigate the yield of imaging in patients with relapsed prostate cancer (PC) with a low trigger prostate-specific antigen (PSA). Materials and methods: This institutional review board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study included all 133 patients (mean age 68 years; range 45–88; median 69 months since original diagnosis; interquartile range [IQR]: 32–139) with hormone-sensitive PC (HSPC, n=28) or castration-resistant PC (CRPC, n=105) and trigger PSA 0.05 for all). Fifty-seven of the 133 (43%) patients had findings seen only at CT, of which 37 had new extra-osseous findings. Only 2/133 (2%) had findings at bone scintigraphy not seen at CT, both in areas not covered on CT. Conclusion: Imaging frequently demonstrated new metastatic and non-metastatic findings in patients with a low trigger PSA. CT is valuable in these patients because extra-osseous findings not visible at bone scintigraphy are frequently seen. - Highlights: • New and existing metastases common in prostate cancer with low trigger PSA. • Previous reports of threshold PSA levels may not apply in follow-up setting. • No difference in metastatic pattern between hormone sensitive and resistant disease. • CT showed extra-osseous findings not seen on bone scan in 44% patients. • Bone scan rarely showed findings not visible on concurrent CT.

  19. Unicuspid aortic valve disease: a magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A. [Klinik und Poliklinik fuer Innere Medizin II, Universitaetsklinikum Regensburg (Germany); Djavidani, B.; Poschenrieder, F.; Feuerbach, S. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schmid, C.; Kobuch, R. [Klinik und Poliklinik fuer Herz-, Thorax- und herznahe Gefaesschirurgie, Universitaetsklinikum Regensburg (Germany)

    2008-11-15

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 {+-} 4.7 cm{sup 2} vs. 8.7 {+-} 2.3 cm{sup 2}, p < 0.01 and 4.6 {+-} 0.7 cm vs. 3.6 {+-} 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 {+-} 0.6 cm vs. 2.3 {+-} 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 {+-} 0.5 cm vs. 2.6 {+-} 0.3 cm, p < 0.05). (orig.)

  20. Numerical Simulations of Competitive-Consecutive Reactions in Turbulent Channel Flow

    NARCIS (Netherlands)

    Vrieling, A.J.

    2003-01-01

    This thesis deals with mixing of passive scalars in a turbulent flow. The passive scalars are released in a turbulent plane channel flow and interpreted as either non-reactive components or reactive components that are involved in a competitive-consecutive reaction system. The evolution of these

  1. Orthogonal polarization spectral imaging of the microcirculation during acute hypervolemic hemodilution and epidural lidocaine injection

    NARCIS (Netherlands)

    van den Oever, Huub L. A.; Dzoljic, Misa; Ince, Can; Hollmann, Markus W.; Mokken, Fleur C.

    2006-01-01

    We used Orthogonal Polarization Spectral Imaging to examine the microcirculation of the vaginal mucosa in nine anesthetized patients during two consecutive anesthetic interventions: hypervolemic hemodilution using hydroxyethyl starch followed by thoracic epidural lidocaine. Images taken before and

  2. Consecutive evaluation of graphene oxide and reduced graphene oxide nanoplatelets immunotoxicity on monocytes.

    Science.gov (United States)

    Yan, Junyan; Chen, Liliang; Huang, Chih-Ching; Lung, Shih-Chun Candice; Yang, Lingyan; Wang, Wen-Cheng; Lin, Po-Hsiung; Suo, Guangli; Lin, Chia-Hua

    2017-05-01

    The biocompatibilities of graphene-family nanomaterials (GFNs) should be thoroughly evaluated before their application in drug delivery and anticancer therapy. The present study aimed to consecutively assess the immunotoxicity of graphene oxide nanoplatelets (GONPs) and reduced GONPs (rGONPs) on THP-1 cells, a human acute monocytic leukemia cell line. GONPs induced the expression of antioxidative enzymes and inflammatory factors, whereas rGONPs had substantially higher cellular uptake rate, higher levels of NF-κB expression. These distinct toxic mechanisms were observed because the two nanomaterials differ in their oxidation state, which imparts different affinities for the cell membrane. Because GONPs have a higher cell membrane affinity and higher impact on membrane proteins compared with rGONPs, macrophages (THP-1a) derived from GONPs treated THP-1cells showed a severer effect on phagocytosis. By consecutive evaluation the effects of GONPs and rGONPs on THP-1 and THP-1a, we demonstrated that their surface oxidation states may cause GFNs to behave differently and cause different immunotoxic effects. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    International Nuclear Information System (INIS)

    Vandervelde, C.; Kamani, T.; Varghese, A.; Ramesar, K.; Grace, R.; Howlett, D.C.

    2008-01-01

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status

  4. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Vandervelde, C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: clivevandervelde@gmail.com; Kamani, T. [Department of ENT Surgery, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: tkamany@yahoo.com; Varghese, A. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: vargheseajay@hotmail.com; Ramesar, K. [Department of Histopathology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: keith.ramesar@esht.nhs.uk; Grace, R. [Department of Haematology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: richard.grace@esht.nhs.uk; Howlett, D.C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: david.howlett@esht.nhs.uk

    2008-04-15

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.

  5. Mobile kidney pain provocation ultrasonography before surgery for symptomatic mobile kidney: A prospective study of 43 consecutive patients.

    Science.gov (United States)

    Arnerlöv, Conny; Söderström, Minette; Öhberg, Lars

    2016-01-01

    The aim of this study was to evaluate whether mobile kidney pain provocation ultrasonography together with intravenous pyelography in supine and standing positions and a full medical history can confirm the diagnosis of the clinical condition of symptomatic mobile kidney and aid the selection of patients for surgical treatment. In a consecutive study, 43 patients with the clinical picture of symptomatic mobile kidney, a positive mobile kidney pain provocation ultrasonography and a renal descent of at least 2 lumbar vertebral heights on intravenous pyelography in the standing position, were operated on with nephropexy. Patients' pain relief after nephropexy was evaluated by clinical follow-up, a questionnaire and visual analogue scale (VAS) scoring. Reduction of pain after nephropexy was associated with a significant decrease in VAS scoring from a median of 8 (range 4-10) preoperatively to a median of 0 (range 0-7) postoperatively (p mobile kidney pain provocation ultrasonography and intravenous pyelography in supine and standing positions can verify the diagnosis of symptomatic mobile kidney and aid the selection of patients who will benefit from nephropexy.

  6. Comparative evaluation of RetCam vs. gonioscopy images in congenital glaucoma.

    Science.gov (United States)

    Azad, Raj V; Chandra, Parijat; Chandra, Anuradha; Gupta, Aparna; Gupta, Viney; Sihota, Ramanjit

    2014-02-01

    To compare clarity, exposure and quality of anterior chamber angle visualization in congenital glaucoma patients, using RetCam and indirect gonioscopy images. Cross-sectional study Participants. Congenital glaucoma patients over age of 5 years. A prospective consecutive pilot study was done in congenital glaucoma patients who were older than 5 years. Methods used are indirect gonioscopy and RetCam imaging. Clarity of the image, extent of angle visible and details of angle structures seen were graded for both methods, on digitally recorded images, in each eye, by two masked observers. Image clarity, interobserver agreement. 40 eyes of 25 congenital glaucoma patients were studied. RetCam image had excellent clarity in 77.5% of patients versus 47.5% by gonioscopy. The extent of angle seen was similar by both methods. Agreement between RetCam and gonioscopy images regarding details of angle structures was 72.50% by observer 1 and 65.00% by observer 2. There was good agreement between RetCam and indirect gonioscopy images in detecting angle structures of congenital glaucoma patients. However, RetCam provided greater clarity, with better quality, and higher magnification images. RetCam can be a useful alternative to gonioscopy in infants and small children without the need for general anesthesia.

  7. Clinical study on microsurgical treatment for craniopharyngioma in a single consecutive institutional series of 335 patients.

    Science.gov (United States)

    Guo, Fuyou; Wang, Guoqing; Suresh, Vigneyshwar; Xu, Dingkang; Zhang, Xiaoyang; Feng, Mengzhao; Wang, Fang; Liu, Xianzhi; Song, Laijun

    2018-04-01

    The optimal management of craniopharyngioma is still controversial. The aim of this study is to explore microsurgical outcomes of craniopharyngioma in 335 cases. Clinical data of 335 consecutive patients with craniopharyngioma between March 2011 and March 2017 were retrospectively analyzed. Gross total resection (GTR) was achieved in 265 cases (79.1%), subtotal resection (STR) was obtained in 70 cases (20.9%). The GTR rate was 81.93% in pediatric group and 78.17% in adult group respectively, no significant difference regarding the GTR rate was found in adult group compared with in pediatric group (p > 0.05). However, there was a noticeable difference in the elevated hypothalamic obesity in children group compared with in adult group after operation (p  0.05). Additionally, there were no statistically significant differences for recurrence-free curves between GTR and STR plus adjuvant radiotherapy (p > 0.05). Present findings demonstrated that tumor recurrence and surgical times contribute to negative total resection for craniopharyngioma. Postoperative precise adjuvant radiotherapy was considered in selected cases if pursuit of GTR was rather dangerous under disadvantageous removal factors. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Computed tomography-urography for upper urinary tract imaging: is it required for all patients who present with hematuria?

    NARCIS (Netherlands)

    Cauberg, Evelyne C. C.; Nio, C. Y.; de la Rosette, Jean M. C. H.; Laguna, M. Pilar; de Reijke, Theo M.

    2011-01-01

    To define in which patients who present with microscopic or macroscopic hematuria CT urography (CTU) is indicated as an imaging mode for the upper urinary tract (UUT). We conducted a prospective study on consecutive patients who attended a modern protocol-driven hematuria clinic from January 2006 to

  9. Body Dysmorphic Disorder and Other Clinically Significant Body Image Concerns in Adolescent Psychiatric Inpatients: Prevalence and Clinical Characteristics

    Science.gov (United States)

    Dyl, Jennifer; Kittler, Jennifer; Phillips, Katharine A.; Hunt, Jeffrey I.

    2006-01-01

    Background: This study assessed prevalence and clinical correlates of body dysmorphic disorder (BDD), eating disorders (ED), and other clinically significant body image concerns in 208 consecutively admitted adolescent inpatients. It was hypothesized that adolescents with BDD would have higher levels of depression, anxiety, and suicidality.…

  10. Image selection in static telepathology through the Internet.

    Science.gov (United States)

    Della Mea, V; Cataldi, P; Boi, S; Finato, N; Della Palma, P; Beltrami, C A

    1998-01-01

    A telepathology study was carried out to examine the differences occurring when the images were selected by an experienced pathologist, a junior pathologist and a first-year resident. One hundred and fifty-five consecutive frozen-section pathology cases were collected and sent for consultation to a remote experienced pathologist using multimedia email. Local diagnoses (as reported in the files of the Institute, not from the image selector) and remote diagnoses (based on the images) were compared with those performed on paraffin-embedded sections. Acquisition time and number of selected images were recorded for each case and used to compare the different behaviour of the three local pathologists. Of the 155 cases sent by telepathology, four were considered insufficient for a diagnosis by the remote pathologist and thus the diagnosis was postponed. In the remaining 151 cases, the overall diagnostic agreement between remote and definitive diagnosis was 96.7%. The results indicate that in the routine diagnostic work of a frozen-section service, an inexperienced pathologist can select images which are sufficiently informative for a remote diagnosis, in a sufficiently short time.

  11. Low-grade Glioma Surgery in Intraoperative Magnetic Resonance Imaging: Results of a Multicenter Retrospective Assessment of the German Study Group for Intraoperative Magnetic Resonance Imaging.

    Science.gov (United States)

    Coburger, Jan; Merkel, Andreas; Scherer, Moritz; Schwartz, Felix; Gessler, Florian; Roder, Constantin; Pala, Andrej; König, Ralph; Bullinger, Lars; Nagel, Gabriele; Jungk, Christine; Bisdas, Sotirios; Nabavi, Arya; Ganslandt, Oliver; Seifert, Volker; Tatagiba, Marcos; Senft, Christian; Mehdorn, Maximilian; Unterberg, Andreas W; Rössler, Karl; Wirtz, Christian Rainer

    2016-06-01

    The ideal treatment strategy for low-grade gliomas (LGGs) is a controversial topic. Additionally, only smaller single-center series dealing with the concept of intraoperative magnetic resonance imaging (iMRI) have been published. To investigate determinants for patient outcome and progression-free-survival (PFS) after iMRI-guided surgery for LGGs in a multicenter retrospective study initiated by the German Study Group for Intraoperative Magnetic Resonance Imaging. A retrospective consecutive assessment of patients treated for LGGs (World Health Organization grade II) with iMRI-guided resection at 6 neurosurgical centers was performed. Eloquent location, extent of resection, first-line adjuvant treatment, neurophysiological monitoring, awake brain surgery, intraoperative ultrasound, and field-strength of iMRI were analyzed, as well as progression-free survival (PFS), new permanent neurological deficits, and complications. Multivariate binary logistic and Cox regression models were calculated to evaluate determinants of PFS, gross total resection (GTR), and adjuvant treatment. A total of 288 patients met the inclusion criteria. On multivariate analysis, GTR significantly increased PFS (hazard ratio, 0.44; P surgery. Patients with accidentally left tumor remnants showed a similar prognosis compared with patients harboring only partially resectable tumors. Use of high-field iMRI was significantly associated with GTR. However, the field strength of iMRI did not affect PFS. EoR, extent of resectionFLAIR, fluid-attenuated inversion recoveryGTR, gross total resectionIDH1, isocitrate dehydrogenase 1iMRI, intraoperative magnetic resonance imagingLGG, low-grade gliomaMGMT, methylguanine-deoxyribonucleic acid methyltransferasenPND, new permanent neurological deficitOS, overall survivalPFS, progression-free survivalSTR, subtotal resectionWHO, World Health Organization.

  12. Development of a dynamic CT system for neutron radiography and consecutive visualization of three-dimensional water behavior in a PEFC stack

    International Nuclear Information System (INIS)

    Murakawa, Hideki; Hashimoto, Michinori; Sugimoto, Katsumi; Asano, Hitoshi; Takenaka, Nobuyuki; Mochiki, Koh-ichi; Yasuda, Ryo

    2011-01-01

    A dynamic CT system was developed for visualization of consecutive three-dimensional water behavior in a PEFC stack for neutron radiography. The system is composed of a neutron image intensifier and a C-MOS high speed video camera. An operating stack with three cells based on the Japan Automobile Research Institute standard was visualized using the neutron radiography system at a research reactor JRR-3 in Japan Atomic Energy Agency. The dynamic water behavior in channels in the operating PEFC stack was clearly visualized every 15 seconds by using the system. The water amount in each cell was evaluated by the CT reconstructed images. It was shown that a cell voltage decreased gradually when the water increased and increased rapidly when the water was evacuated. It was estimated that the power generation stopped when the channel of a cell was partly filled with the water because the air supply was blocked to a cell in the stack. (author)

  13. Rotator cuff tears: should abduction and external rotation (ABER) positioning be performed before image acquisition? A CT arthrography study

    Energy Technology Data Exchange (ETDEWEB)

    Cochet, Hubert [Hopital Cardiologique du Haut-Leveque, CHU Bordeaux, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Couderc, Stephane; Pele, Eric; Moreau-Durieux, Marie-Helene; Hauger, Olivier [Hopital Pellegrin, CHU Bordeaux, Unite d' Imagerie Osteo-articulaire, Bordeaux (France); Amoretti, Nicolas [CHU Archet, Unite d' Imagerie Osteo-articulaire, Nice (France)

    2010-05-15

    To evaluate the impact of abduction and external rotation (ABER) positioning performed before image acquisition on the assessment of rotator cuff tears. Twenty-seven consecutive patients with clinically suspected rotator cuff tears underwent an initial CT arthrogram of the shoulder in neutral position, immediately followed by temporary ABER positioning, before a second CT acquisition in neutral position. Two observers blinded to potential pre-procedure ABER positioning independently analysed the randomly distributed images. Lesions were classified into partial-thickness (PT) and full-thickness (FT) tear subtypes. Lesion detection and measurements of pre- and post-ABER studies were compared. We found no influence of pre-test ABER positioning on FT detection or measurements. Every PT detected on pre-ABER study was also detected on post-ABER study (28/28 for reader 1, and 32/32 for reader 2). Seven and eight additional PT were found by readers 1 and 2, respectively, on post-ABER study. Lesion size increased after ABER in terms of area (P < 0.001 for both readers) and Ellman's grade (P = 0.02 and 0.002 for reader 1 and 2, respectively). ABER positioning before CT is associated with improved delineation of partial tears, a higher number of detected tears and modification of treatment planning. (orig.)

  14. Double-hit BCL2/MYC translocations in a consecutive cohort of patients with large B-cell lymphoma - a single centre's experience

    DEFF Research Database (Denmark)

    Pedersen, Mette Ø; Gang, Anne O; Poulsen, Tim S

    2012-01-01

    Concurrent BCL2 and MYC translocations, so called double hit (DH), are a rare finding in large B-cell lymphoma (LBCL). Based on data from retrospective series, DH has been correlated with aggressive clinical behaviour and poor outcome. We conducted a consecutive study of DH incidence and correlat......Concurrent BCL2 and MYC translocations, so called double hit (DH), are a rare finding in large B-cell lymphoma (LBCL). Based on data from retrospective series, DH has been correlated with aggressive clinical behaviour and poor outcome. We conducted a consecutive study of DH incidence...

  15. Inappropriateness of cardiovascular radiological imaging testing; a tertiary care referral center study.

    Directory of Open Access Journals (Sweden)

    Clara Carpeggiani

    Full Text Available AIMS: Radiological inappropriateness in medical imaging leads to loss of resources and accumulation of avoidable population cancer risk. Aim of the study was to audit the appropriateness rate of different cardiac radiological examinations. METHODS AND PRINCIPAL FINDINGS: With a retrospective, observational study we reviewed clinical records of 818 consecutive patients (67 ± 12 years, 75% males admitted from January 1-May 31, 2010 to the National Research Council - Tuscany Region Gabriele Monasterio Foundation cardiology division. A total of 940 procedures were audited: 250 chest x-rays (CXR; 240 coronary computed tomographies (CCT; 250 coronary angiographies (CA; 200 percutaneous coronary interventions (PCI. For each test, indications were rated on the basis of guidelines class of recommendation and level of evidence: definitely appropriate (A, including class I, appropriate, and class IIa, probably appropriate, uncertain (U, class IIb, probably inappropriate, or inappropriate (I, class III, definitely inappropriate. Appropriateness was suboptimal for all tests: CXR (A = 48%, U = 10%, I = 42%; CCT (A = 58%, U = 24%, I = 18%; CA (A = 45%, U = 25%, I = 30%; PCI (A = 63%, U = 15%, I = 22%. Top reasons for inappropriateness were: routine on hospital admission (70% of inappropriate CXR; first line application in asymptomatic low-risk patients (42% of CCT or in patients with unchanged clinical status post-revascularization (20% of CA; PCI in patients either asymptomatic or with miscellaneous symptoms and without inducible ischemia on non-invasive testing (36% of inappropriate PCI. CONCLUSION AND SIGNIFICANCE: Public healthcare system--with universal access paid for with public money--is haemorrhaging significant resources and accumulating avoidable long-term cancer risk with inappropriate cardiovascular imaging prevention.

  16. A functional magnetic resonance imaging study

    Indian Academy of Sciences (India)

    MADU

    systems and ultra fast imaging techniques, such as echo planar imaging (EPI ) ... is used to understand brain organization, assessing of neurological status, and ..... J C 1998 Functional MRI studies of motor recovery after stroke;. NeuroImage 7 ...

  17. The effects of consecutive night shifts and shift length on cognitive performance and sleepiness: a field study.

    Science.gov (United States)

    Haidarimoghadam, Rashid; Kazemi, Reza; Motamedzadeh, Majid; Golmohamadi, Rostam; Soltanian, Alireza; Zoghipaydar, Mohamad Reza

    2017-06-01

    The aim of this study was to evaluate the effects of consecutive night shifts (CNS) and shift length on cognitive performance and sleepiness. This study evaluated the sleepiness and performance of 30 control room operators (CROs) working in 7 nights, 7 days, 7 days off (7N7D7O) and 30 CROs working in 4 nights, 7 days, 3 nights, 7 days off (4N7D3N7O) shift patterns in a petrochemical complex on the last night shift before swinging into the day shift. To assess cognitive performance, the n-back test, continuous performance test and simple reaction time test were employed. To assess sleepiness, the Karolinska sleepiness scale was used. Both schedules indicated that the correct responses and response times of working memory were reduced (p = 0.001), while intentional errors and sleepiness increased during the shift work (p = 0.001). CNS had a significant impact on reaction time and commission errors (p = 0.001). The main duty of CROs at a petrochemical plant is checking hazardous processes which require appropriate alertness and cognitive performance. As a result, planning for appropriate working hours and suitable number of CNS in a rotating shift system is a contribution to improving CRO performance and enhancing safety.

  18. PREDICTIVE FACTORS OF DIFFICULT INTUBATION IN POST BURN NECK CONTRACTURE – A STUDY OF 30 CONSECUTIVE CASES

    Directory of Open Access Journals (Sweden)

    Vijay

    2015-06-01

    Full Text Available The peri - operative management of post - burn contractures of the neck is a challenge not only to the surgeon but also the anaesthesiologist. A proper co - ordination between them is needed for providing a hassle - free patient care. This is a prospective study done on 30 consecutive patients of post burn contractures of the neck to compare the surgeon’s assessment of the type and pattern of post - burn contracture of the neck and the anaesthesiologist’s assessment of the airway. T he association of this with the peri - operative management of patients was also studied. The data analysed was type of contracture , mento - sternal distance , and preoperative grading of the airway. The method of securing intra - operative airway was documented . A direct co - relation was noted between the type of contracture with the Mallampatti grading of the airway and the sterno - mental distance. All type III contractures required release before intubation. In conclusion , it is advisable for the surgeon to be w ell - versed with the anaesthesiologist’s assessment of the airway and the anaesthesiologist to aware of the types of neck contracture in order to properly plan and execute the peri - operative management of these patients.

  19. Oral health-related quality of life of a consecutive sample of Spanish dental patients

    OpenAIRE

    Montero Martín, Javier; Yarte, José María; Bravo Pérez, Manuel; López-Valverde Centeno, Antonio

    2011-01-01

    Objectives: Assessment of the oral health-related quality of life and the modulating factors of patients deman-- ding dental treatment in the city of Salamanca, through the use of two validated instruments: the OIDP-sp (Oral Impacts on Daily Performance) and OHIP-14 (Oral Health Impact Profile). Study design: the study was conducted on a consecutive sample of 200 patients aged 18-65 years visiting an Integral Dental Centre in the city of Salamanca. Two validated instruments (OIDP-sp and OHIP-...

  20. Wavelet theory applied to remove noise and movement artifacts from images

    International Nuclear Information System (INIS)

    Blanco, S.; Cabrejas, M.L.; Carpintiero, S.; Costa, A.; Stenborg, J.

    2002-01-01

    The quality of the images is in direct relationship with the accuracy of the diagnosis. There are several physical and technical problems (signal to noise ratio, image distortions, geometrical defects, pattern recognition and movement corrections) associated with acquisition and processing devices, each of which require specific solutions. New generation equipment or appropriate quality control techniques, often solve the problem. The option, is trying to correct for image distortions existing on the reconstructed images using post processing mathematical filtering. In this paper a new developed software is described to correct the images and solve the above mentioned problems. Mathematical tools: To improve the signal to noise ratio, a noise reduction method, based on Multi Resolution Analysis with Wavelets, was used. The use of cubic spline wavelets as mother wavelets, is more convenient because they conform an orthogonal basis. For each multi resolution level, a 'hard thresholding' was applied. This means that the coefficients, which are strongly dependent on the images, are put to zero when they are smaller than a reference value. It is also possible to separate the movement of the structures under study from instrumental constraints or noise. To accomplish this, cross-correlations of particular sub-regions, in consecutive images, were performed. Since a quantitative estimation of the error introduced by both effects is rather difficult, a new technique was developed, a so-called trial and error technique (TET), via the identification of a particular subregion on consecutive images, provided there are sharp fixed features present in the considered subregion. This position, being the one in which the standard deviation is the smallest, is then chosen on the second image. Taking into account the time between images and the dynamic characteristic time, the Gaussian distribution confirms the absence of substantial variability form one image to the other. Results

  1. Cardiovascular Magnetic Resonance Imaging-Incremental Value in a Series of 361 Patients Demonstrating Cost Savings and Clinical Benefits: An Outcome-Based Study.

    Science.gov (United States)

    Hegde, Vinayak A; Biederman, Robert Ww; Mikolich, J Ronald

    2017-01-01

    This study was designed to assess the clinical impact and cost-benefit of cardiovascular magnetic resonance imaging (CMR). In the face of current health care cost concerns, cardiac imaging modalities have come under focused review. Data related to CMR clinical impact and cost-benefit are lacking. Retrospective review of 361 consecutive patients (pts) who underwent CMR exams was conducted. Indications for CMR were tabulated for appropriateness criteria. Components of the CMR exam were identified along with evidence of clinical impact. The cost of each CMR exam was ascertained along with cost savings attributable to the CMR exam for calculation of an incremental cost-effectiveness ratio. A total of 354 of 361 pts (98%) had diagnostic quality studies. Of the 361 pts, 350 (97%) had at least 1 published Appropriateness Criterion for CMR. A significant clinical impact attributable to CMR exam results was observed in 256 of 361 pts (71%). The CMR exam resulted in a new diagnosis in 69 of 361 (27%) pts. Cardiovascular magnetic resonance imaging results avoided invasive procedures in 38 (11%) pts and prevented additional diagnostic testing in 26 (7%) pts. Comparison of health care savings using CMR as opposed to current standards of care showed a net cost savings of $833 037, ie, per patient cost savings of $2308. Cardiovascular magnetic resonance imaging provides diagnostic image quality in >98% of cases. Cardiovascular magnetic resonance imaging findings have documentable clinical impact on patient management in 71% of pts undergoing the exam, in a cost beneficial manner.

  2. Intraoperative Magnetic Resonance Imaging in Skull Base Surgery: A Review of 71 Consecutive Cases.

    Science.gov (United States)

    Ashour, Ramsey; Reintjes, Stephen; Park, Michael S; Sivakanthan, Sananthan; van Loveren, Harry; Agazzi, Siviero

    2016-09-01

    Although intraoperative magnetic resonance imaging (iMRI) increasingly is used during glioma resection, its role in skull base surgery has not been well documented. In this study, we evaluate our experience with iMRI for skull base surgery. Medical records were reviewed retrospectively on all neurosurgical cases performed at our institution in the IMRIS iMRI suite between April 2014 and July 2015. During the study period, the iMRI suite was used for 71 skull base tumors. iMRI was performed in 23 of 71 cases. Additional tumor resection was pursued after scanning in 7 of 23 patients. There was a significant difference in procedure length between the scanned versus nonscanned groups, and this was likely attributable to a greater proportion of petroclival meningiomas in the scanned group. Further analyses revealed significant increases in procedure length for the following scanned subgroups: anterolateral approach, anterolateral and petroclival lesion locations, and meningiomas. The rate of non-neurologic complications was significantly greater in the scanned group, particularly for patients with tumors >3 cm. Despite the unique challenges associated with skull base tumor surgery, iMRI can be safely obtained while adding a modest although not prohibitive amount of time to the procedure. The immediate evidence of residual tumor with a patient still in position to have additional resection may influence the surgeon to alter the surgical plan and attempt further resection in a critical area. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. In situ study of the impact of inter- and intra-reader variability on region of interest (ROI) analysis in preclinical molecular imaging.

    Science.gov (United States)

    Habte, Frezghi; Budhiraja, Shradha; Keren, Shay; Doyle, Timothy C; Levin, Craig S; Paik, David S

    2013-01-01

    We estimated reader-dependent variability of region of interest (ROI) analysis and evaluated its impact on preclinical quantitative molecular imaging. To estimate reader variability, we used five independent image datasets acquired each using microPET and multispectral fluorescence imaging (MSFI). We also selected ten experienced researchers who utilize molecular imaging in the same environment that they typically perform their own studies. Nine investigators blinded to the data type completed the ROI analysis by drawing ROIs manually that delineate the tumor regions to the best of their knowledge and repeated the measurements three times, non-consecutively. Extracted mean intensities of voxels within each ROI are used to compute the coefficient of variation (CV) and characterize the inter- and intra-reader variability. The impact of variability was assessed through random samples iterated from normal distributions for control and experimental groups on hypothesis testing and computing statistical power by varying subject size, measured difference between groups and CV. The results indicate that inter-reader variability was 22.5% for microPET and 72.2% for MSFI. Additionally, mean intra-reader variability was 10.1% for microPET and 26.4% for MSFI. Repeated statistical testing showed that a total variability of CV variability has been observed mainly due to differences in the ROI placement and geometry drawn between readers, which may adversely affect statistical power and erroneously lead to negative study outcomes.

  4. Image annotation by deep neural networks with attention shaping

    Science.gov (United States)

    Zheng, Kexin; Lv, Shaohe; Ma, Fang; Chen, Fei; Jin, Chi; Dou, Yong

    2017-07-01

    Image annotation is a task of assigning semantic labels to an image. Recently, deep neural networks with visual attention have been utilized successfully in many computer vision tasks. In this paper, we show that conventional attention mechanism is easily misled by the salient class, i.e., the attended region always contains part of the image area describing the content of salient class at different attention iterations. To this end, we propose a novel attention shaping mechanism, which aims to maximize the non-overlapping area between consecutive attention processes by taking into account the history of previous attention vectors. Several weighting polices are studied to utilize the history information in different manners. In two benchmark datasets, i.e., PASCAL VOC2012 and MIRFlickr-25k, the average precision is improved by up to 10% in comparison with the state-of-the-art annotation methods.

  5. What is the link between nonlocalizing sestamibi scans, multigland disease, and persistent hypercalcemia? A study of 401 consecutive patients undergoing parathyroidectomy.

    Science.gov (United States)

    Chiu, Bill; Sturgeon, Cord; Angelos, Peter

    2006-09-01

    We hypothesized that nonlocalizing sestamibi scans would correlate with multigland disease and persistent primary hyperparathyroidism. We reviewed records for 401 consecutive patients who underwent parathyroidectomy from 1999 to 2004. Gender, age, preoperative imaging, surgical findings, gland weight and volume, and 6-month calcium levels (Ca) were examined. We identified 289 women and 112 men, 297 of whom had a preoperative sestamibi scan localized to a single gland (localized group; LG). Ninety-six percent of the LG were found to have single-gland disease, and 4% had multigland disease (MGD). In the nonlocalized group (NLG), 76% had single-gland disease and 24% MGD. Mean gland weight was greater in the LG than in the NLG (1128 mg vs 699 mg; P localizing sestamibi scan had a positive predictive value (PPV) of 96% and a likelihood ratio of 2.29 for predicting "curative" intraoperative parathyroid hormone drop after removal of a single abnormal gland. Patients were stratified into normocalcemic (NCa) and hypercalcemic (HCa) groups based on 6-month postoperative serum calcium data (n = 328). HCa incidence at 6 months did not differ significantly between the LG (5%) and NLG (3%). A localizing scan had a PPV of 95% for normocalcemia at 6 months. A nonlocalizing scan had a PPV of 21% for HCa at 6 months. Nonlocalizing sestamibi scans were more common in primary hyperparathyroidism with MGD and were associated with smaller-volume abnormal glands found at operation. Preoperative sestamibi scan-results did not predict HCa at 6 months.

  6. Accuracy of reading liquid based cytology slides using the ThinPrep Imager compared with conventional cytology: prospective study

    Science.gov (United States)

    d'Assuncao, Jefferson; Irwig, Les; Macaskill, Petra; Chan, Siew F; Richards, Adele; Farnsworth, Annabelle

    2007-01-01

    Objective To compare the accuracy of liquid based cytology using the computerised ThinPrep Imager with that of manually read conventional cytology. Design Prospective study. Setting Pathology laboratory in Sydney, Australia. Participants 55 164 split sample pairs (liquid based sample collected after conventional sample from one collection) from consecutive samples of women choosing both types of cytology and whose specimens were examined between August 2004 and June 2005. Main outcome measures Primary outcome was accuracy of slides for detecting squamous lesions. Secondary outcomes were rate of unsatisfactory slides, distribution of squamous cytological classifications, and accuracy of detecting glandular lesions. Results Fewer unsatisfactory slides were found for imager read cytology than for conventional cytology (1.8% v 3.1%; Pcytology (7.4% v 6.0% overall and 2.8% v 2.2% for cervical intraepithelial neoplasia of grade 1 or higher). Among 550 patients in whom imager read cytology was cervical intraepithelial neoplasia grade 1 or higher and conventional cytology was less severe than grade 1, 133 of 380 biopsy samples taken were high grade histology. Among 294 patients in whom imager read cytology was less severe than cervical intraepithelial neoplasia grade 1 and conventional cytology was grade 1 or higher, 62 of 210 biopsy samples taken were high grade histology. Imager read cytology therefore detected 71 more cases of high grade histology than did conventional cytology, resulting from 170 more biopsies. Similar results were found when one pathologist reread the slides, masked to cytology results. Conclusion The ThinPrep Imager detects 1.29 more cases of histological high grade squamous disease per 1000 women screened than conventional cytology, with cervical intraepithelial neoplasia grade 1 as the threshold for referral to colposcopy. More imager read slides than conventional slides were satisfactory for examination and more contained low grade cytological

  7. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    International Nuclear Information System (INIS)

    Tuite, M.J.; Asinger, D.; Orwin, J.F.

    2001-01-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  8. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J; Asinger, D; Orwin, J F [Dept. of Radiology, Univ. of Wisconsin Hospital and Clinics, Madison, WI (United States)

    2001-05-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  9. Automatic identification of bullet signatures based on consecutive matching striae (CMS) criteria.

    Science.gov (United States)

    Chu, Wei; Thompson, Robert M; Song, John; Vorburger, Theodore V

    2013-09-10

    The consecutive matching striae (CMS) numeric criteria for firearm and toolmark identifications have been widely accepted by forensic examiners, although there have been questions concerning its observer subjectivity and limited statistical support. In this paper, based on signal processing and extraction, a model for the automatic and objective counting of CMS is proposed. The position and shape information of the striae on the bullet land is represented by a feature profile, which is used for determining the CMS number automatically. Rapid counting of CMS number provides a basis for ballistics correlations with large databases and further statistical and probability analysis. Experimental results in this report using bullets fired from ten consecutively manufactured barrels support this developed model. Published by Elsevier Ireland Ltd.

  10. Plant-microbe rhizosphere interactions mediated by Rehmannia glutinosa root exudates under consecutive monoculture

    Science.gov (United States)

    Wu, Linkun; Wang, Juanying; Huang, Weimin; Wu, Hongmiao; Chen, Jun; Yang, Yanqiu; Zhang, Zhongyi; Lin, Wenxiong

    2015-10-01

    Under consecutive monoculture, the biomass and quality of Rehmannia glutinosa declines significantly. Consecutive monoculture of R. glutinosa in a four-year field trial led to significant growth inhibition. Most phenolic acids in root exudates had cumulative effects over time under sterile conditions, but these effects were not observed in the rhizosphere under monoculture conditions. It suggested soil microbes might be involved in the degradation and conversion of phenolic acids from the monocultured plants. T-RFLP and qPCR analysis demonstrated differences in both soil bacterial and fungal communities during monoculture. Prolonged monoculture significantly increased levels of Fusarium oxysporum, but decreased levels of Pseudomonas spp. Abundance of beneficial Pseudomonas spp. with antagonistic activity against F. oxysporum was lower in extended monoculture soils. Phenolic acid mixture at a ratio similar to that found in the rhizosphere could promote mycelial growth, sporulation, and toxin (3-Acetyldeoxynivalenol, 15-O-Acetyl-4-deoxynivalenol) production of pathogenic F. oxysporum while inhibiting growth of the beneficial Pseudomonas sp. W12. This study demonstrates that extended monoculture can alter the microbial community of the rhizosphere, leading to relatively fewer beneficial microorganisms and relatively more pathogenic and toxin-producing microorganisms, which is mediated by the root exudates.

  11. Minimum distance determination between consecutive carriers in the gamma irradiator IR-200 K trajectory

    International Nuclear Information System (INIS)

    Achmad Suntoro

    2014-01-01

    A design to determine the minimum distance between the consecutive carriers at the trajectory of gamma irradiators IR-200K is implemented. Equilibrium between centrifugal force of a moving carrier in circular trajectory and its gravity force as well as carrier dimensions are used as parameters in determining such a minimum distance. The minimum distance between the consecutive carriers in the design is defined 1.2 meters. The distance is 11.5% greater than the minimum distance theoretically calculated, namely 1,076 meters. Errors tolerance in construction/installation of the trajectory and other unexpected things during irradiator's operation are part of the consideration to enlarge the minimum distance from its theoretical value. The distance between the consecutive carriers will not affect throughput and efficiency of using radiation due to the straight trajectory segments do not need to follow such the minimum distance between the carriers, as the trajectory segments around the i radiation sources are straight. (author)

  12. Prevalence and risk factors for renal scars in children with febrile UTI and/or VUR: a cross-sectional observational study of 565 consecutive patients.

    Science.gov (United States)

    Snodgrass, Warren T; Shah, Anjana; Yang, Mary; Kwon, Jeannie; Villanueva, Carlos; Traylor, Janelle; Pritzker, Karen; Nakonezny, Paul A; Haley, Robert W; Bush, Nicol Corbin

    2013-12-01

    To determine prevalence and risk factors for renal scar in children referred for urologic assessment of febrile UTI and/or VUR. Pre-determined risk factors for renal scar were prospectively recorded in consecutive patients referred for UTI/VUR. Age, gender, VUR grade, and reported number of febrile and non-febrile UTIs were analyzed with logistic regression to determine risk for focal cortical defects on non-acute DMSA. Of 565 consecutive children, 24 (4%) had congenital renal dysplasia and 84 (15.5%) had focal defect(s). VUR, especially grades IV-V, recurrent febrile UTI, and older age increased risk. For any age child with the same number of UTIs, VUR increased odds of renal defect 5.4-fold (OR = 5.4, 95% CI = 2.7-10.6, AUC = 0.759). Focal DMSA defects were present in 15.5% of 565 consecutive children referred for febrile UTI and/or VUR; 4% had presumed congenital reflux nephropathy without cortical defect. All VUR grades increased risk for these defects, as did recurrent febrile UTIs and older age. However, 43% with grades IV-V VUR and 76% with recurrent UTI had normal DMSA. Published by Elsevier Ltd.

  13. Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: a clinical study

    International Nuclear Information System (INIS)

    Vigneault, Eric; Pouliot, Jean; Laverdiere, Jacques; Roy, Jean; Dorion, Marc

    1997-01-01

    Purpose: This study was designed to assess daily prostatic apex motion relative to pelvic bone structures during megavoltage irradiation. Methods and Materials: Radioopaque markers were implanted under ultrasound guidance near the prostatic apex of 11 patients with localized prostatic carcinoma. Patients were subsequently treated with a four field-box technique at a beam energy of 23 MV. During treatment, on-line images were obtained with an electronic portal imaging device (EPID). The marker was easily identified, even on unprocessed images, and the distance between the marker and a bony landmark was measured. Timelapse movies were also reviewed. After the completion of treatment, a transcrectal ultrasound examination was performed in 8 of 11 patients, to verify the position of the marker. Results: We acquired over 900 digital portal images and analyzed posterioanterior and right lateral views. The quality of portal images obtained with megavoltage irradiation was good. It was possible to evaluate pelvic bone structures even without image histogram equalization. Moreover, the radioopaque marker was easily visible on every online portal image. The review of timelapse movies showed important interfraction motion of the marker while bone structures remained stable. We measured the position of the marker for each fraction. Marker displacements up to 1.6 cm were measured between 2 consecutive days of treatment. Important marker motions were predominantly in the posteroanterior and cephalocaudal directions. In eight patients, we verified the position of the marker relative to the prostatic apex with ultrasound at the end of the treatments. The marker remained in the trapezoid zone. Intratreatment images reviewed in two cases showed no change in marker position. Our results, obtained during the treatment courses, indicate similar or larger prostate motions than previously observed in studies that used intertreatment x-ray films and CT images. Marker implantation under

  14. Incidence and MR imaging features of fractures of the anterior process of calcaneus in a consecutive patient population with ankle and foot symptoms

    International Nuclear Information System (INIS)

    Ouellette, H.; Salamipour, H.; Thomas, B.J.; Kassarjian, A.; Torriani, M.

    2006-01-01

    To determine the incidence, appearances and associated injuries of fractures affecting the anterior process of calcaneus from a general population with foot and ankle symptoms. A retrospective review of foot and ankle MR imaging procedures was performed for detection of cases with a fracture affecting the anterior process of calcaneus over a four year period. Radiographs, MR imaging studies, radiology reports, medical records, and operative notes were reviewed. Imaging analysis included fracture pattern, displacement, associated fractures, and presence of tendon and ligamentous injuries. The incidence of anterior process of calcaneus fracture on MR imaging was 0.5% (14/2577). Fractures were more common in female subjects (71%, 10/14). Fracture orientation was predominantly vertical (93%, 13/14). No comminuted fractures were seen and only three fractures were displaced. Three of the eight MR imaging evident fractures of anterior process of calcaneus were seen on radiographs. Associated fractures of the talus (n=5), navicular bone (n=3), cuboid (n=2), and calcaneal body (n=1) were noted. Associated injuries to the anterior talofibular ligament (n=3) and tears of the peroneus brevis (n=3) and peroneus longus (n=1) tendons were present. All fractures were treated non-operatively. Two patients had subtalar joint steroid injection for symptomatic relief

  15. Incidence and MR imaging features of fractures of the anterior process of calcaneus in a consecutive patient population with ankle and foot symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Ouellette, H.; Salamipour, H.; Thomas, B.J.; Kassarjian, A.; Torriani, M. [Division of Musculoskeletal Radiology, Massachusetts General Hospital, Boston, MA (United States)

    2006-11-15

    To determine the incidence, appearances and associated injuries of fractures affecting the anterior process of calcaneus from a general population with foot and ankle symptoms. A retrospective review of foot and ankle MR imaging procedures was performed for detection of cases with a fracture affecting the anterior process of calcaneus over a four year period. Radiographs, MR imaging studies, radiology reports, medical records, and operative notes were reviewed. Imaging analysis included fracture pattern, displacement, associated fractures, and presence of tendon and ligamentous injuries. The incidence of anterior process of calcaneus fracture on MR imaging was 0.5% (14/2577). Fractures were more common in female subjects (71%, 10/14). Fracture orientation was predominantly vertical (93%, 13/14). No comminuted fractures were seen and only three fractures were displaced. Three of the eight MR imaging evident fractures of anterior process of calcaneus were seen on radiographs. Associated fractures of the talus (n=5), navicular bone (n=3), cuboid (n=2), and calcaneal body (n=1) were noted. Associated injuries to the anterior talofibular ligament (n=3) and tears of the peroneus brevis (n=3) and peroneus longus (n=1) tendons were present. All fractures were treated non-operatively. Two patients had subtalar joint steroid injection for symptomatic relief.

  16. Comparative evaluation of RetCam vs. gonioscopy images in congenital glaucoma

    Directory of Open Access Journals (Sweden)

    Raj V Azad

    2014-01-01

    Full Text Available Purpose: To compare clarity, exposure and quality of anterior chamber angle visualization in congenital glaucoma patients, using RetCam and indirect gonioscopy images. Design: Cross-sectional study Participants. Congenital glaucoma patients over age of 5 years. Materials and Methods: A prospective consecutive pilot study was done in congenital glaucoma patients who were older than 5 years. Methods used are indirect gonioscopy and RetCam imaging. Clarity of the image, extent of angle visible and details of angle structures seen were graded for both methods, on digitally recorded images, in each eye, by two masked observers. Outcome Measures: Image clarity, interobserver agreement. Results: 40 eyes of 25 congenital glaucoma patients were studied. RetCam image had excellent clarity in 77.5% of patients versus 47.5% by gonioscopy. The extent of angle seen was similar by both methods. Agreement between RetCam and gonioscopy images regarding details of angle structures was 72.50% by observer 1 and 65.00% by observer 2. Conclusions: There was good agreement between RetCam and indirect gonioscopy images in detecting angle structures of congenital glaucoma patients. However, RetCam provided greater clarity, with better quality, and higher magnification images. RetCam can be a useful alternative to gonioscopy in infants and small children without the need for general anesthesia.

  17. Unicuspid aortic valve disease: a magnetic resonance imaging study

    International Nuclear Information System (INIS)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A.; Djavidani, B.; Poschenrieder, F.; Feuerbach, S.; Schmid, C.; Kobuch, R.

    2008-01-01

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 ± 4.7 cm 2 vs. 8.7 ± 2.3 cm 2 , p < 0.01 and 4.6 ± 0.7 cm vs. 3.6 ± 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 ± 0.6 cm vs. 2.3 ± 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 ± 0.5 cm vs. 2.6 ± 0.3 cm, p < 0.05). (orig.)

  18. Results of the Total Evolutive Shoulder System (TESS): a single-centre study of 56 consecutive patients.

    Science.gov (United States)

    Kadum, Bakir; Mafi, Nader; Norberg, Sigge; Sayed-Noor, Arkan S

    2011-12-01

    Shoulder arthroplasty surgery has undergone remarkable progress. New concepts like reverse and stemless shoulder prostheses have been widely used. The Total Evolutive Shoulder System (TESS) is a new innovative system that provides the surgeon with different prosthetic versions. The purpose of the present study was to evaluate our short-term results and complications of the TESS. 56 consecutive patients were operated with one of the two versions of TESS (anatomical or reverse) between October 2007 and December 2009. Preoperative and postoperative evaluation of the function and life quality was achieved by the Quick Disability of the Arm, Shoulder and Hand (DASH) index and EQ-5D self-report questionnaire, respectively. Radiographic follow-up by anteroposterior, axillary and lateral views was done. The anterosuperior approach was used in all cases. We compared the outcome in fracture patients with other categories. 49 patients were available for 9-24 months (mean 14) clinical and radiographic postoperative follow-up. The mean of quick DASH improved from 56 preoperatively to 34 postoperatively (p TESS prosthesis showed promising short-term results with few complications. The reverse version could be implanted without stem if initial stability was adequate. Long-term follow-up is required to confirm the results of this innovative system in the long run.

  19. Idiopathic Chronic Parotitis: Imaging Findings and Sialendoscopic Response.

    Science.gov (United States)

    Heineman, Thomas E; Kacker, Ashutosh; Kutler, David I

    2015-01-01

    The purpose of this study was to correlate imaging and sialendoscopic findings to therapeutic response in patients with idiopathic chronic parotitis. We retrospectively reviewed 122 consecutive sialendoscopies performed in an academic medical center by two surgeons between 2008 and 2013. Forty-one (34%) and 54 (44%) patients were excluded on the basis of having parotid or submandibular sialolith, respectively. Nineteen cases were included in the study with idiopathic chronic parotitis. There was a median follow-up of 5 months. Computed tomography (CT) imaging had a sensitivity and specificity of 80.0 and 71.4%, respectively, for predicting abnormal findings on sialendoscopy, while magnetic resonance imaging (MRI) had 100% accuracy in a small set of cases. In glands with noticeable pathology present on preoperative imaging or sialendoscopy, 11 out of 12 glands (92%) treated experienced symptomatic improvement, while 3 out of 7 glands (43%) without pathology on imaging or endoscopy experienced symptomatic improvement (p = 0.038). Sialendoscopy for the treatment of idiopathic chronic parotid disease can improve pain and swelling with a higher frequency of success in patients with abnormalities noted on endoscopy. CT and MRI have a moderate degree of accuracy in predicting which patients will benefit from therapeutic sialendoscopy. © 2015 S. Karger AG, Basel.

  20. Fundus Autofluorescence Imaging in an Ocular Screening Program

    Directory of Open Access Journals (Sweden)

    A. M. Kolomeyer

    2012-01-01

    Full Text Available Purpose. To describe integration of fundus autofluorescence (FAF imaging into an ocular screening program. Methods. Fifty consecutive screening participants were included in this prospective pilot imaging study. Color and FAF (530/640 nm exciter/barrier filters images were obtained with a 15.1MP Canon nonmydriatic hybrid camera. A clinician evaluated the images on site to determine need for referral. Visual acuity (VA, intraocular pressure (IOP, and ocular pathology detected by color fundus and FAF imaging modalities were recorded. Results. Mean ± SD age was 47.4 ± 17.3 years. Fifty-two percent were female and 58% African American. Twenty-seven percent had a comprehensive ocular examination within the past year. Mean VA was 20/39 in the right eye and 20/40 in the left eye. Mean IOP was 15 mmHg bilaterally. Positive color and/or FAF findings were identified in nine (18% individuals with diabetic retinopathy or macular edema (n=4, focal RPE defects (n=2, age-related macular degeneration (n=1, central serous retinopathy (n=1, and ocular trauma (n=1. Conclusions. FAF was successfully integrated in our ocular screening program and aided in the identification of ocular pathology. Larger studies examining the utility of this technology in screening programs may be warranted.

  1. Fundus autofluorescence imaging in an ocular screening program.

    Science.gov (United States)

    Kolomeyer, A M; Nayak, N V; Szirth, B C; Khouri, A S

    2012-01-01

    Purpose. To describe integration of fundus autofluorescence (FAF) imaging into an ocular screening program. Methods. Fifty consecutive screening participants were included in this prospective pilot imaging study. Color and FAF (530/640 nm exciter/barrier filters) images were obtained with a 15.1MP Canon nonmydriatic hybrid camera. A clinician evaluated the images on site to determine need for referral. Visual acuity (VA), intraocular pressure (IOP), and ocular pathology detected by color fundus and FAF imaging modalities were recorded. Results. Mean ± SD age was 47.4 ± 17.3 years. Fifty-two percent were female and 58% African American. Twenty-seven percent had a comprehensive ocular examination within the past year. Mean VA was 20/39 in the right eye and 20/40 in the left eye. Mean IOP was 15 mmHg bilaterally. Positive color and/or FAF findings were identified in nine (18%) individuals with diabetic retinopathy or macular edema (n = 4), focal RPE defects (n = 2), age-related macular degeneration (n = 1), central serous retinopathy (n = 1), and ocular trauma (n = 1). Conclusions. FAF was successfully integrated in our ocular screening program and aided in the identification of ocular pathology. Larger studies examining the utility of this technology in screening programs may be warranted.

  2. Revolving SEM images visualising 3D taxonomic characters

    DEFF Research Database (Denmark)

    Akkari, Nesrine; Cheung, David Koon-Bong; Enghoff, Henrik

    2013-01-01

    images taken consecutively while rotating the SEM stage 360°, which allows the structure in question to be seen from all angles of view in one plane. Seven new species of the genus Ommatoiulus collected in Tunisia are described: O. chambiensis, O. crassinigripes, O. kefi, O. khroumiriensis, O. xerophilus...

  3. Image mottle in abdominal CT.

    Science.gov (United States)

    Ende, J F; Huda, W; Ros, P R; Litwiller, A L

    1999-04-01

    To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mottle in CT as a function of x-ray tube potential and mAs. CT images from 39 consecutive patients with noncontrast liver scans and 49 patients with iodine contrast scans were analyzed retrospectively. Measurements were made of the mean liver parenchyma Hounsfield unit value and the corresponding image mottle. For a given water phantom and x-ray tube potential, image mottle was proportional to the mAs-0.5. Increasing the phantom diameter from 16 cm (pediatric) to 32 cm increased the mottle by a factor of 2.4, and increasing the x-ray tube potential from 80 kVp to 140 kVp reduced the mottle by a factor of 2.5. All patients were scanned at 120 kVp, with no correlation between patient size and the x-ray tube mAs. The mean mottle level was 7.8 +/- 2.2 and 10.0 +/- 2.5 for the noncontrast and contrast studies, respectively. An increase in patient diameter of 3 cm would require approximately 65% more mAs to maintain the same level of image mottle. The mottle in abdominal CT images may be controlled by adjusting radiographic technique factors, which should be adjusted to take into account the size of the patient undergoing the examination.

  4. Progressive decrease of melatonin production over consecutive days of simulated night work.

    Science.gov (United States)

    Dumont, Marie; Paquet, Jean

    2014-12-01

    Decreased melatonin production, due to nighttime exposure to light, has been proposed as one of the physiological mechanisms increasing cancer risk in night workers. However, few studies measured melatonin production in night workers, and most of these studies did not measure melatonin over 24 h. One study compared total melatonin production between day and night shifts in rotating night workers and did not find significant differences. However, without baseline measures, it was not possible to exclude that melatonin production was reduced during both day and night work. Here, we used data collected in a simulation study of night work to determine the effect of night work on both nighttime and 24-h melatonin production, during three consecutive days of simulated night work. Thirty-eight healthy subjects (15 men, 23 women; 26.6 ± 4.2 years) participated in a 6-d laboratory study. Circadian phase assessments were made with salivary dim light melatonin onset (DLMO) on the first and last days. Simulated day work (09:00-17:00 h) occurred on the second day, followed by three consecutive days of simulated night work (00:00-08:00 h). Light intensity at eye level was set at 50 lux during both simulated day and night work. The subjects were divided into three matched groups exposed to specific daytime light profiles that produced various degrees of circadian phase delays and phase advances. Melatonin production was estimated with the excretion of urinary 6-sulfatoxymelatonin (aMT6s). For the entire protocol, urine was collected every 2 h, except for the sleep episodes when the interval was 8 h. The aMT6s concentration in each sample was multiplied by the urine volume and then added to obtain total aMT6s excretion during nighttime (00:00-08:00 h) and during each 24-h day (00:00-00:00 h). The results showed that melatonin production progressively decreased over consecutive days of simulated night work, both during nighttime and over the 24 h. This

  5. The Utility of Digital Linear Tomosynthesis Imaging of Total Hip Joint Arthroplasty with Suspicion of Loosening: A Prospective Study in 40 Patients

    Science.gov (United States)

    Göthlin, Jan H.

    2013-01-01

    Aim. The clinical utility of digital linear tomosynthesis in musculoskeletal applications has been validated in only a few reports. Technical performance and utility in hip prosthesis imaging have been discussed in technical reports, but no clinical evaluation has been reported. The purpose of the current study was to assess the added clinical utility of digital linear tomosynthesis compared to radiography in loosening of total hip joint arthroplasty. Materials and Methods. In a prospective study, radiography and digital tomosynthesis were performed in 40 consecutive patients with total hip arthroplasty referred for suspect prosthesis loosening. Tomosynthesis images were compared to anterior-posterior (AP) and cross-table lateral radiographs regarding demarcation and extent of demineralization and osteolysis. Further noted were skeletal fractures, cement fractures, fragmentation, and artifacts interfering with the diagnosis. Results. Tomosynthesis was superior to radiography with sharper delineation of demineralization and osteolysis in the AP projection. A limitation was the inability to generate lateral tomosynthesis images, with inferior assessment of the area anterior and posterior to the acetabular cup compared to cross-table radiographs. Artifacts interfering with diagnosis were found in one hip. Conclusion. Tomosynthesis improved evaluation of total hip arthroplasty in the AP projection but was limited by the lack of lateral projections. PMID:24078921

  6. The Utility of Digital Linear Tomosynthesis Imaging of Total Hip Joint Arthroplasty with Suspicion of Loosening: A Prospective Study in 40 Patients

    Directory of Open Access Journals (Sweden)

    Jan H. Göthlin

    2013-01-01

    Full Text Available Aim. The clinical utility of digital linear tomosynthesis in musculoskeletal applications has been validated in only a few reports. Technical performance and utility in hip prosthesis imaging have been discussed in technical reports, but no clinical evaluation has been reported. The purpose of the current study was to assess the added clinical utility of digital linear tomosynthesis compared to radiography in loosening of total hip joint arthroplasty. Materials and Methods. In a prospective study, radiography and digital tomosynthesis were performed in 40 consecutive patients with total hip arthroplasty referred for suspect prosthesis loosening. Tomosynthesis images were compared to anterior-posterior (AP and cross-table lateral radiographs regarding demarcation and extent of demineralization and osteolysis. Further noted were skeletal fractures, cement fractures, fragmentation, and artifacts interfering with the diagnosis. Results. Tomosynthesis was superior to radiography with sharper delineation of demineralization and osteolysis in the AP projection. A limitation was the inability to generate lateral tomosynthesis images, with inferior assessment of the area anterior and posterior to the acetabular cup compared to cross-table radiographs. Artifacts interfering with diagnosis were found in one hip. Conclusion. Tomosynthesis improved evaluation of total hip arthroplasty in the AP projection but was limited by the lack of lateral projections.

  7. Is pre-operative imaging essential prior to ureteric stone surgery?

    Science.gov (United States)

    Youssef, F R; Wilkinson, B A; Hastie, K J; Hall, J

    2012-09-01

    The aim of this study was to identify patients not requiring ureteric stone surgery based on pre-operative imaging (within 24 hours) prior to embarking on semirigid ureteroscopy (R-URS) for urolithiasis. The imaging of all consecutive patients on whom R-URS for urolithiasis was performed over a 12-month period was reviewed. All patients had undergone a plain x-ray of the kidney, ureters and bladder (KUB), abdominal non-contrast computed tomography (NCCT-KUB) or both on the day of surgery. A total of 96 patients were identified for the study. Stone sizes ranged from 3 mm to 20 mm. Thirteen patients (14%) were cancelled as no stone(s) were identified on pre-operative imaging. Of the patients cancelled, 8 (62%) required NCCT-KUB to confirm spontaneous stone passage. One in seven patients were stone free on the day of surgery. This negates the need for unnecessary anaesthetic and instrumentation of the urinary tract, with the associated morbidity. Up-to-date imaging prior to embarking on elective ureteric stone surgery is highly recommended.

  8. Imaging study on acupuncture points

    Science.gov (United States)

    Yan, X. H.; Zhang, X. Y.; Liu, C. L.; Dang, R. S.; Ando, M.; Sugiyama, H.; Chen, H. S.; Ding, G. H.

    2009-09-01

    The topographic structures of acupuncture points were investigated by using the synchrotron radiation based Dark Field Image (DFI) method. Four following acupuncture points were studied: Sanyinjiao, Neiguan, Zusanli and Tianshu. We have found that at acupuncture point regions there exists the accumulation of micro-vessels. The images taken in the surrounding tissue out of the acupuncture points do not show such kind of structure. It is the first time to reveal directly the specific structure of acupuncture points by X-ray imaging.

  9. Imaging study on acupuncture points

    International Nuclear Information System (INIS)

    Yan, X H; Zhang, X Y; Liu, C L; Dang, R S; Ando, M; Sugiyama, H; Chen, H S; Ding, G H

    2009-01-01

    The topographic structures of acupuncture points were investigated by using the synchrotron radiation based Dark Field Image (DFI) method. Four following acupuncture points were studied: Sanyinjiao, Neiguan, Zusanli and Tianshu. We have found that at acupuncture point regions there exists the accumulation of micro-vessels. The images taken in the surrounding tissue out of the acupuncture points do not show such kind of structure. It is the first time to reveal directly the specific structure of acupuncture points by X-ray imaging.

  10. Display of nuclear medicine imaging studies

    International Nuclear Information System (INIS)

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2002-08-01

    Nuclear medicine imaging studies involve evaluation of a large amount of image data. Digital signal processing techniques have introduced processing algorithms that increase the information content of the display. Nuclear medicine imaging studies require interactive selection of suitable form of display and pre-display processing. Static imaging study requires pre-display processing to detect focal defects. Point operations (histogram modification) along with zoom and capability to display more than one image in one screen is essential. This album mode of display is also applicable to dynamic, MUGA and SPECT data. Isometric display or 3-D graph of the image data is helpful in some cases e.g. point spread function, flood field data. Cine display is used on a sequence of images e.g. dynamic, MUGA and SPECT imaging studies -to assess the spatial movement of tracer with time. Following methods are used at the investigator's discretion for inspection of the 3-D object. 1) Display of orthogonal projections, 2) Display of album of user selected coronal/ sagital/ transverse orthogonal slices, 3) Display of three orthogonal slices through user selected point, 4) Display of a set of orthogonal slices generated in the user-selected volume, 5) Generation and display of 3-D shaded surface. 6) Generation of volume data and display along with the 3-D shaded surface, 7) Side by side display orthogonal slices of two 3-D objects. Displaying a set of two-dimensional slices of a 3-D reconstructed object through shows all the defects but lacks the 3-D perspective. Display of shaded surface lacks the ability to show the embedded defects. Volume display -combining the 3-D surface and gray level volume data is perhaps the best form of display. This report describes these forms of display along with the theory. (author)

  11. Post-contrast T1-weighted sequences in pediatric abdominal imaging: comparative analysis of three different sequences and imaging approach

    Energy Technology Data Exchange (ETDEWEB)

    Roque, Andreia; Ramalho, Miguel; AlObaidy, Mamdoh; Heredia, Vasco; Burke, Lauren M.; De Campos, Rafael O.P.; Semelka, Richard C. [University of North Carolina at Chapel Hill, Department of Radiology, Chapel Hill, NC (United States)

    2014-10-15

    Post-contrast T1-weighted imaging is an essential component of a comprehensive pediatric abdominopelvic MR examination. However, consistent good image quality is challenging, as respiratory motion in sedated children can substantially degrade the image quality. To compare the image quality of three different post-contrast T1-weighted imaging techniques - standard three-dimensional gradient-echo (3-D-GRE), magnetization-prepared gradient-recall echo (MP-GRE) and 3-D-GRE with radial data sampling (radial 3-D-GRE) - acquired in pediatric patients younger than 5 years of age. Sixty consecutive exams performed in 51 patients (23 females, 28 males; mean age 2.5 ± 1.4 years) constituted the final study population. Thirty-nine scans were performed at 3 T and 21 scans were performed at 1.5 T. Two different reviewers independently and blindly qualitatively evaluated all sequences to determine image quality and extent of artifacts. MP-GRE and radial 3-D-GRE sequences had the least respiratory motion (P < 0.0001). Standard 3-D-GRE sequences displayed the lowest average score ratings in hepatic and pancreatic edge definition, hepatic vessel clarity and overall image quality. Radial 3-D-GRE sequences showed the highest scores ratings in overall image quality. Our preliminary results support the preference of fat-suppressed radial 3-D-GRE as the best post-contrast T1-weighted imaging approach for patients under the age of 5 years, when dynamic imaging is not essential. (orig.)

  12. Transfer Learning with Convolutional Neural Networks for Classification of Abdominal Ultrasound Images.

    Science.gov (United States)

    Cheng, Phillip M; Malhi, Harshawn S

    2017-04-01

    The purpose of this study is to evaluate transfer learning with deep convolutional neural networks for the classification of abdominal ultrasound images. Grayscale images from 185 consecutive clinical abdominal ultrasound studies were categorized into 11 categories based on the text annotation specified by the technologist for the image. Cropped images were rescaled to 256 × 256 resolution and randomized, with 4094 images from 136 studies constituting the training set, and 1423 images from 49 studies constituting the test set. The fully connected layers of two convolutional neural networks based on CaffeNet and VGGNet, previously trained on the 2012 Large Scale Visual Recognition Challenge data set, were retrained on the training set. Weights in the convolutional layers of each network were frozen to serve as fixed feature extractors. Accuracy on the test set was evaluated for each network. A radiologist experienced in abdominal ultrasound also independently classified the images in the test set into the same 11 categories. The CaffeNet network classified 77.3% of the test set images accurately (1100/1423 images), with a top-2 accuracy of 90.4% (1287/1423 images). The larger VGGNet network classified 77.9% of the test set accurately (1109/1423 images), with a top-2 accuracy of VGGNet was 89.7% (1276/1423 images). The radiologist classified 71.7% of the test set images correctly (1020/1423 images). The differences in classification accuracies between both neural networks and the radiologist were statistically significant (p convolutional neural networks may be used to construct effective classifiers for abdominal ultrasound images.

  13. Prevalence and Characteristics of Discogenic Pain in Tertiary Practice: 223 Consecutive Cases Utilizing Lumbar Discography.

    Science.gov (United States)

    Verrills, Paul; Nowesenitz, Gillian; Barnard, Adele

    2015-08-01

    Between 26% and 42% of chronic low back pain is attributed to internal disc disruption of lumbar intervertebral discs. These prevalence estimates and data characterizing discogenic pain originate largely from research at elite practices, conducted 20 years ago. With few studies since, their concordance with rates in community practice has rarely been addressed. To assess the prevalence and key features of discogenic pain within community-based tertiary practice, and to evaluate the accuracy and clinical utility of discography. This prospective, three-year study of 223 consecutive cases of chronic low back pain used image-guided lumbar discography to identify symptomatic and flanking asymptomatic discs. A subset of patients (n = 195) had previously undergone posterior column blocks to investigate spinal facet and/or sacroiliac joints as contributing pain sources. A total of 644 discs were tested without infection or complication. Positive discograms were recorded in 74% of patients, with 22.9% negative and 3.1% assessed as indeterminate. Among patients receiving both discography and diagnostic blocks, 63% had proven discogenic pain, 18% had pain of mixed etiology and 14% remained undiagnosed. Taking into account all low back pain cases during this study (n = 756), discogenic pain prevalence was 21.8% (95% CI: 17-26%). The prevalence of discogenic pain in this community practice is below the range, but within confidence intervals, previously reported. Prevalence is considerably elevated, however, among well-selected patients and discography enabled a firm diagnosis in most such cases. These findings are broadly in keeping with those reached in key publications and support the clinical utility of discography. Wiley Periodicals, Inc.

  14. [Prevalence of mental disorder and related treatments in a local jail: a 20-month consecutive case study].

    Science.gov (United States)

    Carrà, Giuseppe; Giacobone, Caterina; Pozzi, Florinda; Alecci, Pasquale; Barale, Francesco

    2004-01-01

    To define the prevalence of mental disorder within an Italian local jail and to describe main psychiatric treatments provided. Cross-sectional study of consecutive male prisoners referred, over a twenty-month period, for a clinical psychiatric assessment, among population (N = 990) of Casa circondariale "Torre del Gallo", Pavia (I); clinical DSM-IV diagnostic assessment and retrospective analysis of provided psychiatric treatments (i.e. psychiatric visits and pharmacological prescriptions). 191 men (19.3%) had one or more current mental disorders (excluding substance misuse), including 13 (1.3%) psychosis; 53 (5.4%) mood disorder; 24 (2.4%) anxiety disorder; 26 (2.6%) adjustment disorder; 40 (4.1%) personality disorder; 32 (3.2%) personality disorder plus mood disorder; 3 (0.3%) mental retardation. Substance- (N = 89, 47%) and HIV-related (N = 19, 10%) disorders comorbidity is recognised. Psychiatric visits are mainly provided to psychosis and personality disorder plus mood disorder subgroups. Off-label antipsychotics prescriptions are frequent. The prevalence of mental disorder in this population is higher than US and EU averages, and for particular diagnostic subgroups it could be underestimated. Psychiatric management in prison should be reorganized according to national and European health guidelines.

  15. Improved MR imaging in extremely inhomogenous radiofrequency fields

    International Nuclear Information System (INIS)

    Bansal, N.; Nunnally, R.L.

    1989-01-01

    A previous study developed a method for acquiring images in extremely inhomogeneous radio-frequency fields with use of adiabatic pulses. Since adiabatic pulses most suited to section selection are the inversion type, the method is prone to artifacts from receiver and analog-to-digital converter (ADC) saturation and subtraction errors. These problems are substantially reduced by using a pseudo-noise-modulated selective (PNMS) prepulse to randomize the unwanted spin magnetization. To compute the PNMS pulse shape, the frequency spectrum of a wave form with constant amplitude and random phase was determined by means of Fourier transformation and then inverted after a consecutive number of points were set to zero in the center. The performance of the prepulse with the imaging sequence was tested on a 1.8-T system. Results are presented

  16. La interpretacion consecutiva: metodologia y tecnicas (Consecutive Interpretation: Methodology and Techniques).

    Science.gov (United States)

    Drallny, Ines

    1987-01-01

    Describes the purpose and appropriate methodology for various levels of interpreter training, for both consecutive and simultaneous interpretation. The importance of relating the intent of the text to the explicit language forms through which that intent is realized is discussed, and appropriate criteria for evaluation of student interpreters are…

  17. Hyperspectral image classifier based on beach spectral feature

    International Nuclear Information System (INIS)

    Liang, Zhang; Lianru, Gao; Bing, Zhang

    2014-01-01

    The seashore, especially coral bank, is sensitive to human activities and environmental changes. A multispectral image, with coarse spectral resolution, is inadaptable for identify subtle spectral distinctions between various beaches. To the contrary, hyperspectral image with narrow and consecutive channels increases our capability to retrieve minor spectral features which is suit for identification and classification of surface materials on the shore. Herein, this paper used airborne hyperspectral data, in addition to ground spectral data to study the beaches in Qingdao. The image data first went through image pretreatment to deal with the disturbance of noise, radiation inconsistence and distortion. In succession, the reflection spectrum, the derivative spectrum and the spectral absorption features of the beach surface were inspected in search of diagnostic features. Hence, spectra indices specific for the unique environment of seashore were developed. According to expert decisions based on image spectrums, the beaches are ultimately classified into sand beach, rock beach, vegetation beach, mud beach, bare land and water. In situ surveying reflection spectrum from GER1500 field spectrometer validated the classification production. In conclusion, the classification approach under expert decision based on feature spectrum is proved to be feasible for beaches

  18. Post mortem magnetic resonance imaging in the fetus, infant and child: A comparative study with conventional autopsy (MaRIAS Protocol

    Directory of Open Access Journals (Sweden)

    Thayyil Sudhin

    2011-12-01

    Full Text Available Abstract Background Minimally invasive autopsy by post mortem magnetic resonance (MR imaging has been suggested as an alternative for conventional autopsy in view of the declining consented autopsy rates. However, large prospective studies rigorously evaluating the accuracy of such an approach are lacking. We intend to compare the accuracy of a minimally invasive autopsy approach using post mortem MR imaging with that of conventional autopsy in fetuses, newborns and children for detection of the major pathological abnormalities and/or determination of the cause of death. Methods/Design We recruited 400 consecutive fetuses, newborns and children referred for conventional autopsy to one of the two participating hospitals over a three-year period. We acquired whole body post mortem MR imaging using a 1.5 T MR scanner (Avanto, Siemens Medical Solutions, Enlargen, Germany prior to autopsy. The total scan time varied between 90 to 120 minutes. Each MR image was reported by a team of four specialist radiologists (paediatric neuroradiology, paediatric cardiology, paediatric chest & abdominal imaging and musculoskeletal imaging, blinded to the autopsy data. Conventional autopsy was performed according to the guidelines set down by the Royal College of Pathologists (UK by experienced paediatric or perinatal pathologists, blinded to the MR data. The MR and autopsy data were recorded using predefined categorical variables by an independent person. Discussion Using conventional post mortem as the gold standard comparator, the MR images will be assessed for accuracy of the anatomical morphology, associated lesions, clinical usefulness of information and determination of the cause of death. The sensitivities, specificities and predictive values of post mortem MR alone and MR imaging along with other minimally invasive post mortem investigations will be presented for the final diagnosis, broad diagnostic categories and for specific diagnosis of each system

  19. Microencapsulation of indocyanine green for potential applications in image-guided drug delivery.

    Science.gov (United States)

    Zhu, Zhiqiang; Si, Ting; Xu, Ronald X

    2015-02-07

    We present a novel process to encapsulate indocyanine green (ICG) in liposomal droplets at high concentration for potential applications in image-guided drug delivery. The microencapsulation process follows two consecutive steps of droplet formation by liquid-driven coaxial flow focusing (LDCFF) and solvent removal by oil phase dewetting. These biocompatible lipid vesicles may have important applications in drug delivery and fluorescence imaging.

  20. Postoperative morbidity after reconstruction of alveolar bone defects with chin bone transplants in cleft patients - 111 consecutive patients

    DEFF Research Database (Denmark)

    Andersen, Kristian; Nørholt, Sven Erik; Knudsen, Johan

    Postoperative morbidity after reconstruction of alveolar bone defects with chin bone transplants in cleft patients - 111 consecutive patients......Postoperative morbidity after reconstruction of alveolar bone defects with chin bone transplants in cleft patients - 111 consecutive patients...

  1. Detection of peritoneal dissemination in gynecological malignancy: evaluation by diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Fujii, Shinya; Matsusue, Eiji; Kanasaki, Yoshiko; Nakanishi, Junko; Sugihara, Shuji; Ogawa, Toshihide; Kanamori, Yasunobu; Kigawa, Junzo; Terakawa, Naoki

    2008-01-01

    The aim of this study is to evaluate the usefulness of diffusion-weighted (DW) magnetic resonance (MR) imaging in detecting peritoneal dissemination in cases of gynecological malignancy. We retrospectively analyzed MR images obtained from 26 consecutive patients with gynecological malignancy. Peritoneal dissemination was histologically diagnosed in 15 of the 26 patients after surgery. We obtained DW images and half-Fourier single-shot turbo-spin-echo images in the abdomen and pelvis, and then generated fusion images. Coronal maximum-intensity-projection images were reconstructed from the axial source images. Reader interpretations were compared with the laparotomy findings in the surgical records. Receiver-operating characteristic (ROC) curves were used to represent the presence of peritoneal dissemination. In addition, the sensitivity and specificity were calculated. DW imaging depicted the tumors in 14 of 15 patients with peritoneal dissemination as abnormal signal intensity. ROC analysis yielded Az values of 0.974 and 0.932 for the two reviewers. The mean sensitivity and specificity were 90 and 95.5%. DW imaging plays an important role in the diagnosis and therapeutic management of patients with gynecological malignancy. (orig.)

  2. Dual photon excitation microscopy and image threshold segmentation in live cell imaging during compression testing.

    Science.gov (United States)

    Moo, Eng Kuan; Abusara, Ziad; Abu Osman, Noor Azuan; Pingguan-Murphy, Belinda; Herzog, Walter

    2013-08-09

    Morphological studies of live connective tissue cells are imperative to helping understand cellular responses to mechanical stimuli. However, photobleaching is a constant problem to accurate and reliable live cell fluorescent imaging, and various image thresholding methods have been adopted to account for photobleaching effects. Previous studies showed that dual photon excitation (DPE) techniques are superior over conventional one photon excitation (OPE) confocal techniques in minimizing photobleaching. In this study, we investigated the effects of photobleaching resulting from OPE and DPE on morphology of in situ articular cartilage chondrocytes across repeat laser exposures. Additionally, we compared the effectiveness of three commonly-used image thresholding methods in accounting for photobleaching effects, with and without tissue loading through compression. In general, photobleaching leads to an apparent volume reduction for subsequent image scans. Performing seven consecutive scans of chondrocytes in unloaded cartilage, we found that the apparent cell volume loss caused by DPE microscopy is much smaller than that observed using OPE microscopy. Applying scan-specific image thresholds did not prevent the photobleaching-induced volume loss, and volume reductions were non-uniform over the seven repeat scans. During cartilage loading through compression, cell fluorescence increased and, depending on the thresholding method used, led to different volume changes. Therefore, different conclusions on cell volume changes may be drawn during tissue compression, depending on the image thresholding methods used. In conclusion, our findings confirm that photobleaching directly affects cell morphology measurements, and that DPE causes less photobleaching artifacts than OPE for uncompressed cells. When cells are compressed during tissue loading, a complicated interplay between photobleaching effects and compression-induced fluorescence increase may lead to interpretations in

  3. MR imaging of pituitary adenomas: Role of Gd-DTPA

    International Nuclear Information System (INIS)

    Dooms, G.; Mathurin, P.; Cornelis, G.; Demeure, R.

    1988-01-01

    A prospective study was performed to compare the results of CT and MR imaging in the detection of pituitary adenomas. Fifty consecutive unselected patients (40 female and ten male; mean age, 37 years) were studied by both modalities, which were always performed within a 1-week interval. The results were interpreted independently by two different investigators. Findings were confirmed by follow-up (clinical data and repeated examination), surgery, or biologic data for each patient. CT was performed with mainly the Philips Tomoscan 350 and with intravenous bolus of contrast material, at least in the direct coronal plane. MR imaging was performed with a superconducting magnet Philips Gyroscan S15 operating at 1.5 T. Coronal and sagittal T1-weighted images (repetition time = 470 msec, echo time = 30 msec) were performed in every patient (four averages, field of view = 200 mm, 3-mm section thickness with 0.6-mm gap between contiguous sections). Results of both modalities were identical in all 25 patients with macroadenomas (>10mm). However, MR imaging distinction between empty sell and necrotic (or cystic) macroadenomas was easier than that of CT (two patients)

  4. Associations between number of consecutive night shifts and impairment of neurobehavioral performance during a subsequent simulated night shift.

    Science.gov (United States)

    Magee, Michelle; Sletten, Tracey L; Ferguson, Sally A; Grunstein, Ronald R; Anderson, Clare; Kennaway, David J; Lockley, Steven W; Rajaratnam, Shantha Mw

    2016-05-01

    This study aimed to investigate sleep and circadian phase in the relationships between neurobehavioral performance and the number of consecutive shifts worked. Thirty-four shift workers [20 men, mean age 31.8 (SD 10.9) years] worked 2-7 consecutive night shifts immediately prior to a laboratory-based, simulated night shift. For 7 days prior, participants worked their usual shift sequence, and sleep was assessed with logs and actigraphy. Participants completed a 10-minute auditory psychomotor vigilance task (PVT) at the start (~21:00 hours) and end (~07:00 hours) of the simulated night shift. Mean reaction times (RT), number of lapses and RT distribution was compared between those who worked 2-3 consecutive night shifts versus those who worked 4-7 shifts. Following 4-7 shifts, night shift workers had significantly longer mean RT at the start and end of shift, compared to those who worked 2-3 shifts. The slowest and fastest 10% RT were significantly slower at the start, but not end, of shift among participants who worked 4-7 nights. Those working 4-7 nights also demonstrated a broader RT distribution at the start and end of shift and had significantly slower RT based on cumulative distribution analysis (5 (th), 25 (th), 50 (th), 75 (th)percentiles at the start of shift; 75th percentile at the end of shift). No group differences in sleep parameters were found for 7 days and 24 hours prior to the simulated night shift. A greater number of consecutive night shifts has a negative impact on neurobehavioral performance, likely due to cognitive slowing.

  5. Enterobacteriaceae meningitis in adults: a review of 20 consecutive cases 1977-1997

    DEFF Research Database (Denmark)

    Harder, Eva; Møller, Kirsten; Skinhøj, Peter

    1999-01-01

    Enterobacteriaceae are not a frequent cause of meningitis in adults and are seen mainly in neurosurgical patients and on occasion in elderly and debilitated patients. Consequently, most series studied have been small and selected. In order to obtain a clearer clinical picture, we reviewed 20...... consecutive cases of Enterobacteriaceae meningitis admitted to the Department of Infectious Diseases, Rigshospitalet, Copenhagen, during the years 1977-97. They comprised 1.5% of all cases of acute bacterial meningitis admitted to the department. All of the patients were either elderly and/or had 1 or more......% survived with different sequelae. These high rates may, at least in part, be due to the advanced age and debilitated state of the patients studied. Escherichia coli was the most frequent of the Enterobacteriaceae....

  6. Re-thinking the store image study approach

    DEFF Research Database (Denmark)

    Hansen, Kåre

    2001-01-01

    Store image has traditionally been of interest in the Western markets. Studies of store image have also assessed the image of one or a few competing stores. This paper develops an approach to capture store images of an entire retail sector, an issue of importance when enter-ing the new emerging...

  7. Smear correction of highly variable, frame-transfer CCD images with application to polarimetry.

    Science.gov (United States)

    Iglesias, Francisco A; Feller, Alex; Nagaraju, Krishnappa

    2015-07-01

    Image smear, produced by the shutterless operation of frame-transfer CCD detectors, can be detrimental for many imaging applications. Existing algorithms used to numerically remove smear do not contemplate cases where intensity levels change considerably between consecutive frame exposures. In this report, we reformulate the smearing model to include specific variations of the sensor illumination. The corresponding desmearing expression and its noise properties are also presented and demonstrated in the context of fast imaging polarimetry.

  8. The clinical impact of a combined gamma camera/CT imaging system on somatostatin receptor imaging of neuroendocrine tumours

    International Nuclear Information System (INIS)

    Hillel, P.G.; Beek, E.J.R. van; Taylor, C.; Lorenz, E.; Bax, N.D.S.; Prakash, V.; Tindale, W.B.

    2006-01-01

    AIM: With a combined gamma camera/CT imaging system, CT images are obtained which are inherently registered to the emission images and can be used for the attenuation correction of SPECT and for mapping the functional information from these nuclear medicine tomograms onto anatomy. The aim of this study was to evaluate the clinical impact of SPECT/CT using such a system for somatostatin receptor imaging (SRI) of neuroendocrine tumours. MATERIALS AND METHODS: SPECT/CT imaging with 111 In-Pentetreotide was performed on 29 consecutive patients, the majority of whom had carcinoid disease. All SPECT images were first reported in isolation and then re-reported with the addition of the CT images for functional anatomical mapping (FAM). RESULTS: Fifteen of the 29 SPECT images were reported as abnormal, and in 11 of these abnormal images (73%) FAM was found to either establish a previously unknown location (7/11) or change the location (4/11) of at least one lesion. The revised location could be independently confirmed in 64% of these cases. Confirmation of location was not possible in the other patients due to either a lack of other relevant investigations, or the fact that lesions seen in the SPECT images were not apparent in the other investigations. FAM affected patient management in 64% of the cases where the additional anatomical information caused a change in the reported location of lesions. CONCLUSION: These results imply that FAM can improve the reporting accuracy for SPECT SRI with significant impact on patient management

  9. Evaluation of ambiguous genitalia with MR imaging

    International Nuclear Information System (INIS)

    Secaf, E.; Nuruddin, R.; Hricak, H.; Conte, F.A.

    1989-01-01

    To assess the potential of MR imaging in the evaluation of patients with ambiguous genitalia. Twenty-three consecutive patients with ambiguous genitalia at birth or phenotypic anomalies at puberty were included in this study. MR imaging was performed on a 1.5-T unit using T1- (600/30) and T2- (2,500/70) weighted sequences. In patients aged 5 years or less, 3-mm contiguous sagittal and transaxial sections were obtained. The same imaging planes at 5-mm intervals were obtained in older patients. MR findings were compared to those of surgery (n = 14) or biochemical assays (n = 9). Diagnoses included true hermaphroditism (n = 2), pseudohermaphroditism (n = 6), Turner syndrome (n = 2), testicular feminization (n = 2), adrenogenital syndrome (n = 3), vaginal agenesis (n = 3), cloacal abnormality (n = 2), microphallus (n = 2), and double phallus (n = 1. MR imaging correctly identified the presence or absence of the vagina (n = 10) and uterus (n = 9), thus helping in the diagnosis and management of patients with ambiguous genitalia. Demonstration of development of corpora cavernosa, corpora spongiosa, undescended testis, or partial vaginal agenesis assisted in the surgical approach

  10. Adhesive capsulitis: role of MR imaging in differential diagnosis

    International Nuclear Information System (INIS)

    Connell, David; Padmanabhan, Ravi; Buchbinder, Rachelle

    2002-01-01

    The purpose of this study was to describe and characterize the MR imaging findings in a group of patients who underwent surgery for adhesive capsulitis. Twenty-four MR imaging studies in 24 consecutive patients with clinical evidence of adhesive capsulitis were performed prior to arthroscopic capsulotomy. There were 17 women and 7 men with a mean age of 53.5 years. Images were scrutinised for changes in the synovium particularly in the rotator interval, around the biceps anchor and axillary pouch. Intravenous gadolinium was given routinely. We also examined a control group of 22 patients who underwent the same MR imaging protocol after referral for rotator cuff pathology. Soft tissue density showing variable enhancement after gadolinium administration was visible in the rotator interval in 22 of 24 studies on MR imaging. Seventeen patients showed soft tissue density partially encasing the biceps anchor. Ten patients showed thickening and gadolinium enhancement of the axillary pouch. Three patients from the study cohort had partial tears of the supraspinatus tendon. All the patients subsequently had surgery which confirmed fibrovascular scar tissue in the rotator interval, around the biceps anchor and a variable degree of synovial inflammation of the glenohumeral capsule. Two patients from a control group with suspected rotator cuff pathology showed abnormal intensity in the rotator interval on MR imaging. Magnetic resonance imaging can identify changes in the shoulder joint that correspond to abnormalities seen at surgery. This may be useful for discriminating adhesive capsulitis from other causes of shoulder pain. (orig.)

  11. Peritoneal fluid causing inferior attenuation on SPECT thallium-201 myocardial imaging in women

    International Nuclear Information System (INIS)

    Rab, S.T.; Alazraki, N.P.; Guertler-Krawczynska, E.

    1988-01-01

    On SPECT thallium images, myocardial left ventricular (LV) anterior wall attenuation due to breast tissue is common in women. In contrast, in men, inferior wall counts are normally decreased compared to anterior counts. The purpose of this report is to describe cases of inferior wall attenuation of counts in women caused by peritoneal fluid, not myocardial disease. Twelve consecutive SPECT thallium myocardial studies performed in women on peritoneal dialysis, being evaluated for kidney transplant, were included in this study. For all studies, 3.5 mCi 201Tl were injected intravenously. Thirty-two images were acquired over 180 degrees (45 degrees RAO progressing to 45 degrees LPO) at 40 sec per stop. SPECT images were reviewed in short axis, horizontal long and vertical long axes. Data were also displayed in bullseye format with quantitative comparison to gender-matched normal files. Ten of 12 female patients studied had inferior wall defects on images, confirmed by bullseye display. All patients had approximately 2 liters of peritoneal fluid. Review of planar rotational views showed diaphragm elevation and fluid margin attenuations affecting left ventricular inferior wall. Thus, peritoneal fluid is a cause of inferior attenuation on 201Tl cardiac imaging

  12. Detection rates in pediatric diagnostic imaging: a picture archive and communication system compared with a web-based imaging system

    International Nuclear Information System (INIS)

    McDonald, L.; Cramer, B.; Barrett, B.

    2006-01-01

    This prospective study assesses whether there are differences in accuracy of interpretation of diagnostic images among users of a picture archive and communication system (PACS) diagnostic workstation, compared with a less costly Web-based imaging system on a personal computer (PC) with a high resolution monitor. One hundred consecutive pediatric chest or abdomen and skeletal X-rays were selected from hospital inpatient and outpatient studies over a 5-month interval. They were classified as normal (n = 32), obviously abnormal (n = 33), or having subtle abnormal findings (n = 35) by 2 senior radiologists who reached a consensus for each individual case. Subsequently, 5 raters with varying degrees of experience independently viewed and interpreted the cases as normal or abnormal. Raters viewed each image 1 month apart on a PACS and on the Web-based PC imaging system. There was no relation between accuracy of detection and the system used to evaluate X-ray images (P = 0.92). The total percentage of incorrect interpretations on the Web-based PC imaging system was 23.2%, compared with 23.6% on the PACS (P = 0.92). For all raters combined, the overall difference in proportion assessed incorrectly on the PACS, compared with the PC system, was not significant at 0.4% (95%CI, -3.5% to 4.3%). The high-resolution Web-based imaging system via PC is an adequate alternative to a PACS clinical workstation. Accordingly, the provision of a more extensive network of workstations throughout the hospital setting could have potentially significant cost savings. (author)

  13. Microwave Imaging of Human Forearms: Pilot Study and Image Enhancement

    Directory of Open Access Journals (Sweden)

    Colin Gilmore

    2013-01-01

    Full Text Available We present a pilot study using a microwave tomography system in which we image the forearms of 5 adult male and female volunteers between the ages of 30 and 48. Microwave scattering data were collected at 0.8 to 1.2 GHz with 24 transmitting and receiving antennas located in a matching fluid of deionized water and table salt. Inversion of the microwave data was performed with a balanced version of the multiplicative-regularized contrast source inversion algorithm formulated using the finite-element method (FEM-CSI. T1-weighted MRI images of each volunteer’s forearm were also collected in the same plane as the microwave scattering experiment. Initial “blind” imaging results from the utilized inversion algorithm show that the image quality is dependent on the thickness of the arm’s peripheral adipose tissue layer; thicker layers of adipose tissue lead to poorer overall image quality. Due to the exible nature of the FEM-CSI algorithm used, prior information can be readily incorporated into the microwave imaging inversion process. We show that by introducing prior information into the FEM-CSI algorithm the internal anatomical features of all the arms are resolved, significantly improving the images. The prior information was estimated manually from the blind inversions using an ad hoc procedure.

  14. A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism.

    Science.gov (United States)

    Ko, Toshiyuki; Utanohara, Yuko; Suzuki, Yasuhiro; Kurihara, Makiko; Iguchi, Nobuo; Umemura, Jun; Sumiyoshi, Tetsuya; Tomoike, Hitonobu

    2016-01-01

    Simultaneous dual-isotope SPECT imaging with 201Tl and (123)I-β-methyl-p-iodophenylpentadecanoic acid (BMIPP) is used to study the perfusion-metabolism mismatch. It predicts post-ischemic functional recovery by detecting stunned myocardium. On the other hand, (99m)Tc-MIBI is another radioisotope widely used in myocardial perfusion imaging because of its better image quality and lower radiation exposure than 201Tl. However, since the photopeak energies of (99m)Tc and (123)I are very similar, crosstalk hampers the simultaneous use of these two radioisotopes. To overcome this problem, we conducted simultaneous dual-isotope imaging study using the D-SPECT scanner (Spectrum-Dynamics, Israel) which has a novel detector design and excellent energy resolution. We first conducted a basic experiment using cardiac phantom to simulate the condition of normal perfusion and impaired fatty acid metabolism. Subsequently, we prospectively recruited 30 consecutive patients who underwent successful percutaneous coronary intervention for acute myocardial infarction, and performed (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging within 5 days after reperfusion. Images were interpreted by two experienced cardiovascular radiologists to identify the infarcted and stunned areas based on the coronary artery territories. As a result, cardiac phantom experiment revealed no significant crosstalk between (99m)Tc and (123)I. In the subsequent clinical study, (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging in all participant yielded excellent image quality and detected infarcted and stunned areas correctly when compared with coronary angiographic findings. Furthermore, we were able to reduce radiation exposure to significantly approximately one-eighth. In conclusion, we successfully demonstrated the practical application of simultaneous assessment of myocardial perfusion and fatty acid metabolism by (99m)Tc-MIBI and (123)I-BMIPP using a D-SPECT cardiac scanner. Compared with conventional (201)Tl

  15. Reevaluation of JPEG image compression to digitalized gastrointestinal endoscopic color images: a pilot study

    Science.gov (United States)

    Kim, Christopher Y.

    1999-05-01

    Endoscopic images p lay an important role in describing many gastrointestinal (GI) disorders. The field of radiology has been on the leading edge of creating, archiving and transmitting digital images. With the advent of digital videoendoscopy, endoscopists now have the ability to generate images for storage and transmission. X-rays can be compressed 30-40X without appreciable decline in quality. We reported results of a pilot study using JPEG compression of 24-bit color endoscopic images. For that study, the result indicated that adequate compression ratios vary according to the lesion and that images could be compressed to between 31- and 99-fold smaller than the original size without an appreciable decline in quality. The purpose of this study was to expand upon the methodology of the previous sty with an eye towards application for the WWW, a medium which would expand both clinical and educational purposes of color medical imags. The results indicate that endoscopists are able to tolerate very significant compression of endoscopic images without loss of clinical image quality. This finding suggests that even 1 MB color images can be compressed to well under 30KB, which is considered a maximal tolerable image size for downloading on the WWW.

  16. Working with a fixed operating room team on consecutive similar cases and the effect on case duration and turnover time.

    Science.gov (United States)

    Stepaniak, Pieter S; Vrijland, Wietske W; de Quelerij, Marcel; de Vries, Guus; Heij, Christiaan

    2010-12-01

    If variation in procedure times could be controlled or better predicted, the cost of surgeries could be reduced through improved scheduling of surgical resources. This study on the impact of similar consecutive cases on the turnover, surgical, and procedure times tests the perception that repeating the same manual tasks reduces the duration of these tasks. We hypothesize that when a fixed team works on similar consecutive cases the result will be shorter turnover and procedure duration as well as less variation as compared with the situation without a fixed team. Case-control study. St Franciscus Hospital, a large general teaching hospital in Rotterdam, the Netherlands. Two procedures, inguinal hernia repair and laparoscopic cholecystectomy, were selected and divided across a control group and a study group. Patients were randomly assigned to the study or control group. Preparation time, surgical time, procedure time, and turnover time. For inguinal hernia repair, we found a significantly lower preparation time and 10 minutes less procedure time in the study group, as compared with the control group. Variation in the study group was lower, as compared with the control group. For laparoscopic cholecystectomy, preparation time was significantly lower in the study group, as compared with the control group. For both procedures, there was a significant decrease in turnover time. Scheduling similar consecutive cases and performing with a fixed team results in lower turnover times and preparation times. The procedure time of the inguinal hernia repair decreased significantly and has practical scheduling implications. For more complex surgery, like laparoscopic cholecystectomy, there is no effect on procedure time.

  17. Functional resonance magnetic imaging (fMRI) in adolescents with idiopathic musculoskeletal pain: a paradigm of experimental pain

    OpenAIRE

    Molina, Juliana; Amaro, Edson; da Rocha, Liana Guerra Sanches; Jorge, Liliana; Santos, Flavia Heloisa; Len, Claudio A.

    2017-01-01

    Background Studies on functional magnetic resonance imaging (fMRI) have shown that adults with musculoskeletal pain syndromes tolerate smaller amount of pressure (pain) as well as differences in brain activation patterns in areas related to pain.The objective of this study was to evaluate, through fMRI, the brain activation in adolescents with idiopathic musculoskeletal pain (IMP) while performing an experimental paradigm of pain. Methods The study included 10 consecutive adolescents with idi...

  18. Establishment study of the in vivo imaging analysis with small animal imaging modalities for bio-durg development

    International Nuclear Information System (INIS)

    Jang, Beomsu; Park, Sanghyeon; Choi, Dae Seong; Park, Jeonghoon; Jung, Uhee; Lee, Yun Jong

    2012-01-01

    In this study, we established the image modalities (micro-PET, SPECT/CT) using the experimental animal (mouse) for the development of imaging assessment method for the bio-durg and extramural collaboration proposal. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with 99m Tc tricarbonyl bifunctional chelators and 18 F-clotrimazole derivative. SPECT imaging studies were performed with 99m Tc tricarbonyl BFCs. PET imaging study was performed with 18 F-clotrimazole derivatives. We performed the PET image study of 18 F-clotrimazole derivatives using U87MG tumor bearing mice. Also we tested the intramural and extramural collaboration using small animal imaging modalities and prepared the draft of extramural R and D operation manual for small animal imaging modalities and the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug

  19. Multislice CT imaging of anomalous coronary arteries

    International Nuclear Information System (INIS)

    Shi Heshui; Aschoff, Andrik J.; Brambs, Hans-Juergen; Hoffmann, Martin H.K.

    2004-01-01

    The purpose of the present study was to evaluate the role of 16 multislice computed tomography (MSCT) to identify the origin of anomalous coronary arteries and to confirm their anatomic course in relation to the great vessels. Accuracy of coronary artery disease (CAD) detection was a secondary aim and was tested with conventional angiograms (CA) serving as standard of reference. Two hundred and forty-two consecutive patients referred for noninvasive coronary CT imaging were reviewed for the study. Sixteen patients (6.6%) with anomalous coronary arteries were detected and included as the study group. MSCT and CA images were analyzed in a blinded fashion for accuracy of anomalous artery origin and path detection. Results were compared in a secondary consensus evaluation. Accuracy ratios to detect CAD with MSCT in all vessels were calculated. Coronary anomalies for all 16 patients were correctly displayed on MSCT. CA alone achieved correct identification of the abnormality in only 53% (P=0.016). Sensitivity and specificity of MSCT to detect significantly stenosed vessels was 90 and 92%. 16-MSCT is accurate to delineate abnormally branching coronary arteries and allows sufficiently accurate detection of obstructive coronary artery disease in distal branches. It should therefore be considered as a prime non-invasive imaging tool for suspected coronary anomalies. (orig.)

  20. Systematic front distortion and presence of consecutive fronts in a precipitation system

    NARCIS (Netherlands)

    Volford, A.; Izsak, F.; Ripszam, M.; Lagzi, I.

    2006-01-01

    A new simple reaction-diffusion system is presented focusing on pattern formation phenomena as consecutive precipitation fronts and distortion of the precipitation front.The chemical system investigated here is based on the amphoteric property of aluminum hydroxide and exhibits two unique phenomena.

  1. Automated image registration for FDOPA PET studies

    International Nuclear Information System (INIS)

    Kang-Ping Lin; Sung-Cheng Huang, Dan-Chu Yu; Melega, W.; Barrio, J.R.; Phelps, M.E.

    1996-01-01

    In this study, various image registration methods are investigated for their suitability for registration of L-6-[18F]-fluoro-DOPA (FDOPA) PET images. Five different optimization criteria including sum of absolute difference (SAD), mean square difference (MSD), cross-correlation coefficient (CC), standard deviation of pixel ratio (SDPR), and stochastic sign change (SSC) were implemented and Powell's algorithm was used to optimize the criteria. The optimization criteria were calculated either unidirectionally (i.e. only evaluating the criteria for comparing the resliced image 1 with the original image 2) or bidirectionally (i.e. averaging the criteria for comparing the resliced image 1 with the original image 2 and those for the sliced image 2 with the original image 1). Monkey FDOPA images taken at various known orientations were used to evaluate the accuracy of different methods. A set of human FDOPA dynamic images was used to investigate the ability of the methods for correcting subject movement. It was found that a large improvement in performance resulted when bidirectional rather than unidirectional criteria were used. Overall, the SAD, MSD and SDPR methods were found to be comparable in performance and were suitable for registering FDOPA images. The MSD method gave more adequate results for frame-to-frame image registration for correcting subject movement during a dynamic FDOPA study. The utility of the registration method is further demonstrated by registering FDOPA images in monkeys before and after amphetamine injection to reveal more clearly the changes in spatial distribution of FDOPA due to the drug intervention. (author)

  2. Recent lung imaging studies

    International Nuclear Information System (INIS)

    Taplin, G.V.; Chopra, S.K.

    1976-01-01

    Radionuclide lung imaging procedures have been available for 11 years but only the perfusion examination has been used extensively and mainly for the diagnosis of pulmonary embolism (P.E.). Its ability to reveal localized ischemia makes it a valuable test of regional lung function as well as a useful diagnostic aid in P.E. Although it had been recognized for several years that chronic obstructive pulmonary disease (COPD) can cause lung perfusion defects which may simulate pulmonary embolism, relatively little use has been made of either the radioxenon or the radioaerosol inhalation lung imaging procedures until the last few years as a means of distinguishing P.E. from COPD. In this review emphasis is placed on our recent experience with both of these inhalation procedures in comparison with pulmonary function tests and roentgenography for the early detection of COPD in population studies. Equal emphasis is given to simultaneous aerosol ventilation-perfusion (V/P) imaging for a functional diagnosis of P.E. Two new developments in regional lung diffusion imaging, performed after the inhalation of radioactive gases and/or rapidly absorbed radioaerosols are described. The experimental basis for their potential clinical application in pulmonary embolism detection is presented

  3. Fast-flow lingual vascular anomalies in the young patient: is imaging diagnostic?

    International Nuclear Information System (INIS)

    Khong, Pek-Lan; Burrows, Patricia E.; Kozakewich, Harry P.; Mulliken, John B.

    2003-01-01

    To describe the imaging findings (MR imaging and angiography) of high-flow vascular anomalies of the tongue, hemangiomas and arteriovenous malformations (AVMs), with emphasis on the discrepant imaging findings in lingual AVMs. Retrospective review of clinical records, histologic reports and imaging studies of five consecutive patients with high-flow lingual vascular anomalies. One patient had hemangioma (aged 1 month) and four patients had AVMs (aged 15 months, 6, 24, and 33 years). Diagnosis was made on the basis of histology in four lesions and was based on typical clinical history in one lesion. MR imaging and angiographic findings of the hemangioma were typical, but similar findings of focal hyperintense mass on T2-weighted images and angiographic stain were seen in three AVMs (patients aged 15 months, 6 and 33 years). On angiography, there was no nidus or direct arteriovenous (AV) shunting in one AVM (patient aged 15 months). The fourth AVM had typical MR imaging and angiographic findings. The imaging findings in lingual AVMs can be atypical or inconclusive and can mimic hemangiomas, especially in the young patient. Since treatment depends on accurate diagnosis, biopsy may be necessary for lesions with inconclusive imaging findings. (orig.)

  4. MR imaging of hypoglycemic encephalopathy: lesion distribution and prognosis prediction by diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Jeong-Hyun; Kim, Young-Joo; Yoo, Won-Jong; Ihn, Yon-Kwon; Kim, Jee-Young; Kim, Bum-Soo [The Catholic University of Korea, Department of Radiology, College of Medicine, Uijongbu, Kyunggi-do (Korea); Song, Ha-Hun [Cheju Halla General Hospital, Department of Radiology, Jeju (Korea)

    2009-10-15

    The aim of this study was to evaluate the patterns of hypoglycemic encephalopathy on diffusion-weighted imaging (DWI) and the relationship between the imaging patterns and clinical outcomes. This retrospective study included 17 consecutive patients that had hypoglycemic encephalopathy with DWI abnormalities. The topographic distributions of the DWI abnormalities of the cortex, deep gray matter, and white matter structures were assessed. In addition, possible correlation between the patterns of brain injury on DWI and clinical outcomes was investigated. There were three patterns of DWI abnormalities: involvement of both gray and white matter (n=8), selective involvement of gray matter (n=4), and selective involvement of white matter (n=5). There was no significant difference in the initial blood glucose levels among patients for each of the imaging patterns. Most patients (16/17) had bilateral symmetrical abnormalities. Among patients with bilateral symmetrical gray and/or white matter injuries, one had moderate to severe disability and 14 remained in a persistent vegetative state. The two patients with a focal unilateral white matter abnormality and a localized splenial abnormality recovered without neurological deficits. The results of this study showed that white matter was more sensitive to hypoglycemia than previously thought and there was no specific association between the patterns of injury and clinical outcomes whether the cerebral cortex, deep gray matter, and/or white matter were affected. Diffuse and extensive injury observed on the DWI predicts a poor neurologic outcome in patients with hypoglycemic injuries. (orig.)

  5. MR imaging of the prostate at 3 Tesla: comparison of an external phased-array coil to imaging with an endorectal coil at 1.5 Tesla.

    Science.gov (United States)

    Sosna, Jacob; Pedrosa, Ivan; Dewolf, William C; Mahallati, Houman; Lenkinski, Robert E; Rofsky, Neil M

    2004-08-01

    To qualitatively compare the image quality of torso phased-array 3-Tesla (3T) imaging of the prostate with that of endorectal 1.5-Tesla imaging. Twenty cases of torso phased-array prostate imaging performed at 3-Tesla with FSE T2 weighted images were evaluated by two readers independently for visualization of the posterior border (PB), seminal vesicles (SV), neurovascular bundles (NVB), and image quality rating (IQR). Studies were performed at large fields of view(FOV) (25 cm) (14 cases) (3TL) and smaller FOV (14 cm) (19 cases) (3TS). A comparison was made to 20 consecutive cases of 1.5-T endorectal evaluation performed during the same time period.Results. 3TL produced a significantly better image quality compared with the small FOV for PB (P = .0001), SV (P =.0001), and IQR (P = .0001). There was a marginally significant difference within the NVB category (P = .0535). 3TL produced an image of similar quality to image quality at 1.5 T for PB (P = .3893), SV (P = .8680), NB (P = .2684), and IQR (P = .8599). Prostate image quality at 3T with a torso phased-array coil can be comparable with that of endorectal 1.5-T imaging. These findings suggest that additional options are now available for magnetic resonance imaging of the prostate gland.

  6. Late whiplash syndrome: a clinical and magnetic resonance imaging study.

    Science.gov (United States)

    Bonuccelli, U; Pavese, N; Lucetti, C; Renna, M R; Gambaccini, G; Bernardini, S; Canapicchi, R; Carrozzi, L; Murri, L

    1999-01-01

    Cervical hyperextension injuries are common and are associated with significant morbidity. Clinically two syndromes are described: "acute" whiplash syndrome and "late" whiplash syndrome (in which the patients are still symptomatic after six months despite normal physical and radiological examination). In order to clarify the pathology of the persistent pain in late whiplash syndrome we performed a cervical spine magnetic resonance imaging (MRI) in 33 consecutive patients suffering from this condition. Twenty-six patients (78.8%) showed MRI abnormalities, the most common MRI finding (57.6%) was pre-existent spondylosis. Indeed, the group of patients with spondylosis and other MRI changes had higher clinical scores than those without MRI abnormalities as measured by a three-point grading system based upon the symptoms and signs shown. Several MRI changes, most of them already demonstrable by standard X-ray were seen among 33 patients suffering from late whiplash syndrome. Although no one of these findings appears to be specific and certainly related to the previous neck injury, they could represent a risk factor for a longer pain duration.

  7. Automated melanoma detection with a novel multispectral imaging system: results of a prospective study

    International Nuclear Information System (INIS)

    Tomatis, Stefano; Carrara, Mauro; Bono, Aldo; Bartoli, Cesare; Lualdi, Manuela; Tragni, Gabrina; Colombo, Ambrogio; Marchesini, Renato

    2005-01-01

    The aim of this research was to evaluate the performance of a new spectroscopic system in the diagnosis of melanoma. This study involves a consecutive series of 1278 patients with 1391 cutaneous pigmented lesions including 184 melanomas. In an attempt to approach the 'real world' of lesion population, a further set of 1022 not excised clinically reassuring lesions was also considered for analysis. Each lesion was imaged in vivo by a multispectral imaging system. The system operates at wavelengths between 483 and 950 nm by acquiring 15 images at equally spaced wavelength intervals. From the images, different lesion descriptors were extracted related to the colour distribution and morphology of the lesions. Data reduction techniques were applied before setting up a neural network classifier designed to perform automated diagnosis. The data set was randomly divided into three sets: train (696 lesions, including 90 melanomas) and verify (348 lesions, including 53 melanomas) for the instruction of a proper neural network, and an independent test set (347 lesions, including 41 melanomas). The neural network was able to discriminate between melanomas and non-melanoma lesions with a sensitivity of 80.4% and a specificity of 75.6% in the 1391 histologized cases data set. No major variations were found in classification scores when train, verify and test subsets were separately evaluated. Following receiver operating characteristic (ROC) analysis, the resulting area under the curve was 0.85. No significant differences were found among areas under train, verify and test set curves, supporting the good network ability to generalize for new cases. In addition, specificity and area under ROC curve increased up to 90% and 0.90, respectively, when the additional set of 1022 lesions without histology was added to the test set. Our data show that performance of an automated system is greatly population dependent, suggesting caution in the comparison with results reported in the

  8. Gen-2 Hand-Held Optical Imager towards Cancer Imaging: Reflectance and Transillumination Phantom Studies

    Directory of Open Access Journals (Sweden)

    Anuradha Godavarty

    2012-02-01

    Full Text Available Hand-held near-infrared (NIR optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2 hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s allows for reflectance imaging (as in ultrasound and transillumination or compressed imaging (as in X-ray mammography. Phantom studies were performed to demonstrate two-dimensional (2D target detection via reflectance and transillumination imaging at various target depths (1–5 cm deep and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.

  9. Comparative study of fast T 2-weighted images using respiratory triggered, breath-hold, fat suppression and phased array multi coil for liver evaluation by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Abbehusen, Cristiane L.; D'Ippolito, Giuseppe; Palacio, Glaucia A.S.; Szejnfeld, Jacob

    2003-01-01

    The objective of this study was to compare both qualitatively and quantitatively six T 2-weighted turbo spin-echo sequences varying the respiratory compensation technique, associating or not fat tissue suppression and using different types of coils. We performed a prospective study of 71 consecutive patients that were submitted to MRI of the liver using a 1.5 T magnet. The six following pulse sequences were used: fat-suppressed respiratory triggered with conventional body coil; breath-hold fat-suppressed with conventional body coil; non-suppressed respiratory triggered with conventional body coil; breath-hold non fat-suppressed with conventional body coil; fat-suppressed respiratory triggered with phased-array multi coil; breath-hold fat-suppressed with phased-array multi coil. Images were analyzed quantitatively by measuring the signal-to-noise ratios and qualitatively by evaluating the sharpness of hepatic contours, visibility of intrahepatic vessels and other segmental landmarks, and the presence of artifacts. Results: the qualitative analysis showed that the mean values obtained with the six sequences were 7.8, 4.6, 7.9, 5.2, 6.7 and 4.6 respectively. The respiratory-triggered sequences were better than the breath-hold sequences in both qualitative and quantitative analysis (p < 0.001). No significant differences in the values of signal-to-noise ratios and in overall image quality were found between the sequences with and without fat suppression (p . 0.05). The sequences using the body coil were similar in terms of image quality (p . 0.05) and better regarding signal-to-noise ratios than those obtained with the phased=array multi coil (p ,0.001). Our qualitative and quantitative results suggest that the best MRI sequences for the valuation of the liver are the sequences with respiratory triggering using a conventional body coil, with or without fat suppression. (author)

  10. Trends in the incidence of benign pathological lesions at partial nephrectomy for presumed renal cell carcinoma in renal masses on preoperative computed tomography imaging. A single institute experience with 290 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung-Hwan; Park, Sang-Un; Rha, Koon-Ho; Choi, Young-Deuk; Hong, Sung-Joon; Yang, Seung-Choul; Mah, Sang-Yol; Chung, Byung-Ha [Health System, Yonsei Univ., Seoul (Korea, Republic of)

    2010-06-15

    The aim of this study was to determine trends in the incidence of benign lesions in patients undergoing surgery for suspicious renal masses on preoperative computed tomography scan. The records of 1065 patients who underwent open consecutive partial nephrectomy (PN) or radical nephrectomy (RN) between January 2001 and December 2008 were reviewed. Patients who underwent PN during the periods 2001-2002, 2003-2004, 2005-2006, and 2007-2008 were assigned to groups 1, 2, 3 and 4, respectively. The frequencies of benign and malignant lesions in these groups were assessed according to size and histology subtypes. The ratio of PN to RN was 12.4%, 18.3%, 24.3% and 37.2% in groups 1, 2, 3 and 4, respectively (P<0.05). The mean size of resected lesions was 2.6 cm (range 0.8-6.2 cm). Of the 290 cases, histopathology revealed benign findings in 52 (17.9%). Benign pathology was found in three of 18 cases (16.7%) in group 1, seven of 36 cases (19.4%) in group 2, 12 of 63 cases (19.0%) in group 3 and 30 of 173 cases (17.3%) in group 4. There was no significant difference in the frequency of benign histology among groups. PN, as opposed to RN, has shown a rising tendency over time. The frequency of benign pathology findings after PN for suspicious renal masses on preoperative computed tomography imaging has not decreased. Proper management should favor nephron-sparing surgery for renal lesions if such lesions can be removed satisfactorily with PN. (author)

  11. Effectiveness of diffusion tensor imaging in assessing disease severity in Duchenne muscular dystrophy: preliminary study

    International Nuclear Information System (INIS)

    Ponrartana, Skorn; Hu, Houchun Harry; Ramos-Platt, Leigh; Wren, Tishya Anne Leong; Gilsanz, Vicente; Perkins, Thomas Gardner; Chia, Jonathan Mawlin

    2015-01-01

    There is currently a lack of suitable objective endpoints to measure disease progression in Duchenne muscular dystrophy (DMD). Emerging research suggests that diffusion tensor imaging (DTI) has potential as an outcome measure for the evaluation of skeletal muscle injury. The objective of this study was to evaluate the potential of DTI as quantitative magnetic resonance imaging (MRI) markers of disease severity in DMD. Thirteen consecutive boys (8.9 years ± 3.0 years) with DMD were evaluated using DTI. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were compared with clinical outcome measures of manual muscle testing and MRI determinations of muscle fat fraction (MFF) in the right lower extremity. Both MRI measures of FA and ADC strongly correlated with age and muscle strength. Values for FA positively correlated with age and negatively correlated with muscle strength (r = 0.78 and -0.96; both P ≤ 0.002) while measures of ADC negatively correlated age, but positively correlated with muscle strength (r = -0.87 and 0.83; both P ≤ 0.0004). Additionally, ADC and FA strongly correlated with MFF (r = -0.891 and 0.894, respectively; both P ≤ 0.0001). Mean MMF was negatively correlated with muscle strength (r = -0.89, P = 0.0001). DTI measures of muscle structure strongly correlated with muscle strength and adiposity in boys with DMD in this pilot study, although these markers may be more reflective of fat replacement rather than muscle damage in later stages of the disease. Further studies in presymptomatic younger children are needed to assess the ability of DTI to detect early changes in DMD. (orig.)

  12. Effectiveness of diffusion tensor imaging in assessing disease severity in Duchenne muscular dystrophy: preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Ponrartana, Skorn; Hu, Houchun Harry [Children' s Hospital Los Angeles, Department of Radiology, Los Angeles, CA (United States); Ramos-Platt, Leigh [Children' s Hospital Los Angeles, Department of Neurology, Los Angeles, CA (United States); Wren, Tishya Anne Leong; Gilsanz, Vicente [Children' s Hospital Los Angeles, Department of Radiology, Los Angeles, CA (United States); Children' s Hospital Los Angeles, Department of Orthopaedic Surgery, Los Angeles, CA (United States); Perkins, Thomas Gardner; Chia, Jonathan Mawlin [Philips Healthcare North America, Cleveland, OH (United States)

    2015-04-01

    There is currently a lack of suitable objective endpoints to measure disease progression in Duchenne muscular dystrophy (DMD). Emerging research suggests that diffusion tensor imaging (DTI) has potential as an outcome measure for the evaluation of skeletal muscle injury. The objective of this study was to evaluate the potential of DTI as quantitative magnetic resonance imaging (MRI) markers of disease severity in DMD. Thirteen consecutive boys (8.9 years ± 3.0 years) with DMD were evaluated using DTI. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were compared with clinical outcome measures of manual muscle testing and MRI determinations of muscle fat fraction (MFF) in the right lower extremity. Both MRI measures of FA and ADC strongly correlated with age and muscle strength. Values for FA positively correlated with age and negatively correlated with muscle strength (r = 0.78 and -0.96; both P ≤ 0.002) while measures of ADC negatively correlated age, but positively correlated with muscle strength (r = -0.87 and 0.83; both P ≤ 0.0004). Additionally, ADC and FA strongly correlated with MFF (r = -0.891 and 0.894, respectively; both P ≤ 0.0001). Mean MMF was negatively correlated with muscle strength (r = -0.89, P = 0.0001). DTI measures of muscle structure strongly correlated with muscle strength and adiposity in boys with DMD in this pilot study, although these markers may be more reflective of fat replacement rather than muscle damage in later stages of the disease. Further studies in presymptomatic younger children are needed to assess the ability of DTI to detect early changes in DMD. (orig.)

  13. Brain imaging studies of sleep disorder

    International Nuclear Information System (INIS)

    Nakamura, Masaki; Inoue, Yuichi

    2014-01-01

    Brain imaging studies of narcolepsy (NA)/cataplexy (CA), a typical sleep disorder, are summarized together with techniques of functional and structural imaging means. single photon emission CT (SPECT) is based on the distribution of tracers labeled by single photon emitters like 99m Tc and 123 I for seeing the blood flow and receptors. PET using positron emitters like 15 O and 18 F for blood flow and for glucose metabolism, respectively, is of higher resolution and more quantitative than SPECT. Functional MRI (fMRI) depicts the cerebral activity through signal difference by blood oxygenation level dependence (BOLD) effect, and MR spectroscopy (MRS) depicts and quantifies biomaterials through the difference of their nuclear chemical shifts in the magnetic field. Morphologic imaging studies involve the measurement of the volume of the region of interest by comparison with the reference region such as the whole brain volume. Voxel-based morphometry (VBM) has changed to its more advanced surface-based analysis (SBA) of T1-enhanced image. Diffusion tensor imaging (DTI) is based on the tissue water diffusion. Functional SPECT/PET studies have suggested the decrease of blood flow and metabolic activity in the hypothalamus (HT) and other related regions at the conscious resting state, and locally increased blood flow in cingulate gyrus (CG) and amygdaloid complex (AC) at affective CA/PA seizure. fMRI has suggested the hypoactivity of HT and hyperactivity of AC at the seizure. VBM-based studies have not given the consistent results, but DTI studies have suggested an important participation of AC at the seizure. (T.T.)

  14. In-phase and out-of-phase gradient-echo imaging in abdominal studies: intra-individual comparison of three different techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ramalho, Miguel; Heredia, Vasco; Campos, Rafael O. P. de; Azevedo, Rafael M.; Semelka, Richard C. (Dept. of Radiology, Univ. of North Carolina at Chapel Hill (United States)); Dale, Brian M. (Siemens Medical Systems, Morrisville (United States)), email: richsem@med.unc.edu

    2012-05-15

    Background: T1-weighted gradient-echo in-phase and out-of-phase imaging is an essential component of comprehensive abdominal MR exams. It is useful for the study of fat-containing lesions and to identify various disease states related to the presence of fat in the liver. Purpose: To compare three T1-weighted in-phase and out-of-phase (IP/OP) gradient-echo imaging sequences in an intra-individual fashion, and to determine whether advantages exist for each of these sequences for various patient types. Material and Methods: One hundred and eighteen consecutive subjects (74 men, 44 women; mean age 53.9 +- 13.8 years) who had MRI examinations containing all three different IP/OP sequences (two-dimensional spoiled gradient-echo [2D-GRE], three-dimensional gradient-echo [3D-GRE], and magnetization-prepared gradient-recall echo [MP-GRE]) were included. Two different reviewers independently and blindly qualitatively evaluated IP/OP sequences to determine image quality, extent of artifacts, lesion detectability and conspicuity, and subjective grading of liver steatosis for the various sequences. Quantitative analysis was also performed. Qualitative and quantitative data were subjected to statistical analysis. Results: Respiratory ghosting, parallel imaging, and truncation artifacts as well as shading and blurring were more pronounced with 3D-GRE IP/OP imaging. Overall image quality was higher with 2D-GRE (P < 0.05). Detectability of low-fluid content lesions was lower with IP/OP MP-GRE sequences. MP-GRE sequences had the lowest SNRs (P < 0.001). Liver-to-spleen and liver-to-lesion CNRs were significantly lower with 3D-GRE and MP-GR, respectively (P < 0.001). Fat liver indexes showed strongly positive correlation between all sequences. Conclusion: Currently, 2D-GRE remains the best approach for clinical IP/OP imaging. The good image quality of MP-GRE sequences acquired in a free-breathing manner should recommend its use in patients unable to suspend breathing

  15. In-phase and out-of-phase gradient-echo imaging in abdominal studies: intra-individual comparison of three different techniques

    International Nuclear Information System (INIS)

    Ramalho, Miguel; Heredia, Vasco; Campos, Rafael O. P. de; Azevedo, Rafael M.; Semelka, Richard C.; Dale, Brian M.

    2012-01-01

    Background: T1-weighted gradient-echo in-phase and out-of-phase imaging is an essential component of comprehensive abdominal MR exams. It is useful for the study of fat-containing lesions and to identify various disease states related to the presence of fat in the liver. Purpose: To compare three T1-weighted in-phase and out-of-phase (IP/OP) gradient-echo imaging sequences in an intra-individual fashion, and to determine whether advantages exist for each of these sequences for various patient types. Material and Methods: One hundred and eighteen consecutive subjects (74 men, 44 women; mean age 53.9 ± 13.8 years) who had MRI examinations containing all three different IP/OP sequences (two-dimensional spoiled gradient-echo [2D-GRE], three-dimensional gradient-echo [3D-GRE], and magnetization-prepared gradient-recall echo [MP-GRE]) were included. Two different reviewers independently and blindly qualitatively evaluated IP/OP sequences to determine image quality, extent of artifacts, lesion detectability and conspicuity, and subjective grading of liver steatosis for the various sequences. Quantitative analysis was also performed. Qualitative and quantitative data were subjected to statistical analysis. Results: Respiratory ghosting, parallel imaging, and truncation artifacts as well as shading and blurring were more pronounced with 3D-GRE IP/OP imaging. Overall image quality was higher with 2D-GRE (P < 0.05). Detectability of low-fluid content lesions was lower with IP/OP MP-GRE sequences. MP-GRE sequences had the lowest SNRs (P < 0.001). Liver-to-spleen and liver-to-lesion CNRs were significantly lower with 3D-GRE and MP-GR, respectively (P < 0.001). Fat liver indexes showed strongly positive correlation between all sequences. Conclusion: Currently, 2D-GRE remains the best approach for clinical IP/OP imaging. The good image quality of MP-GRE sequences acquired in a free-breathing manner should recommend its use in patients unable to suspend breathing

  16. Abnormalities on diffusion-weighted magnetic resonance imaging in patients with transient ischemic attack

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Tomomi; Shibagaki, Yasuro [Ushiku Aiwa General Hospital, Ibaraki (Japan); Uchiyama, Shinichiro; Iwata, Makoto [Tokyo Women' s Medical Coll. (Japan)

    2003-03-01

    We studied abnormalities on diffusion-weighted magnetic resonance imaging (DWI) in patients with transient ischemic attack (TIA). Out of 18 consecutive TIA patients, 9 patients had relevant focal abnormalities on DWI. Among TIA patients, six patients were associated with atrial fibrillation (Af), and all of these patients had focal abnormalities on DWI as well. TIA patients with Af had significantly more frequent focal abnormalities on DWI than those without Af (p=0.009; Fisher's exact probability test). In addition, the duration of TIA symptoms was not related to the presence of focal abnormalities on DWI. These results indicate that embolic mechanism may cause focal abnormalities on DWI. DWI was more sensitive to detect responsible ischemic lesions in these patients than T2-weighted image or fluid-attenuated inversion recovery image. (author)

  17. Abnormalities on diffusion-weighted magnetic resonance imaging in patients with transient ischemic attack

    International Nuclear Information System (INIS)

    Nakamura, Tomomi; Shibagaki, Yasuro; Uchiyama, Shinichiro; Iwata, Makoto

    2003-01-01

    We studied abnormalities on diffusion-weighted magnetic resonance imaging (DWI) in patients with transient ischemic attack (TIA). Out of 18 consecutive TIA patients, 9 patients had relevant focal abnormalities on DWI. Among TIA patients, six patients were associated with atrial fibrillation (Af), and all of these patients had focal abnormalities on DWI as well. TIA patients with Af had significantly more frequent focal abnormalities on DWI than those without Af (p=0.009; Fisher's exact probability test). In addition, the duration of TIA symptoms was not related to the presence of focal abnormalities on DWI. These results indicate that embolic mechanism may cause focal abnormalities on DWI. DWI was more sensitive to detect responsible ischemic lesions in these patients than T2-weighted image or fluid-attenuated inversion recovery image. (author)

  18. Prospective, double-blind comparison of shoulder MR imaging, US, arthrography, and arthroscopy

    International Nuclear Information System (INIS)

    Resendes, M.; Drace, J.E.; Pyka, W.

    1988-01-01

    To determine the efficacy of diagnostic imaging modalities in the evaluation of shoulder pain, magnetic resonance (MR) imaging, ultrasonography (US) and arthrography were prospectively compared in a double-blind experimental protocol. Thirty consecutive patients were studied by these modalities, which received separate, blinded interpretations. The images and interpretations were sealed in an envelope and blinded from the arthroscopist for initial arthroscopy, but second-look arthroscopy, and in some cases open surgery, was performed after the envelopes were unsealed. To avoid selection bias, negative MR and/or US examinations never affected confirmation by arthrography and/or arthroscopy, so negatives and positives were equivalently tested. To date, MR imaging and US are equally sensitive in the detection of rotator cuff tears, but the combination is more sensitive. Both MR imaging and US demonstrated tears not diagnosed by means of arthrography, and MR imaging distinguished hemorrhagic muscle tears from rotator cuff tears, which arthrography and arthroscopy did not. Both MR imaging and US showed characteristic appearances of biceps tendonitis, but neither demonstrated adhesive capsulitis. The authors conclude that all three imaging modalities have a role in shoulder diagnosis

  19. Adding attenuation corrected images in myocardial perfusion imaging reduces the need for a rest study

    International Nuclear Information System (INIS)

    Trägårdh, Elin; Valind, Sven; Edenbrandt, Lars

    2013-01-01

    The American Society of Nuclear Cardiology and the Society of Nuclear Medicine conclude that incorporation of attenuation corrected (AC) images in myocardial perfusion scintigraphy (MPS) will improve diagnostic accuracy. The aim was to investigate the value of adding AC stress-only images for the decision whether a rest study is necessary or not. 1,261 patients admitted to 99m Tc MPS were studied. The stress studies were interpreted by two physicians who judged each study as “no rest study necessary” or “rest study necessary”, by evaluating NC stress-only and NC + AC stress-only images. When there was disagreement between the two physicians, a third physician evaluated the studies. Thus, agreement between 2 out of 3 physicians was evaluated. The physicians assessed 214 more NC + AC images than NC images as “no rest study necessary” (17% of the study population). The number of no-rest-study-required was significantly higher for NC + AC studies compared to NC studies (859 vs 645 cases (p < 0.0001). In the final report according to clinical routine, ischemia or infarction was reported in 23 patients, assessed as “no rest study necessary” (22 NC + AC cases; 8 NC cases), (no statistically significant difference). In 11 of these, the final report stated “suspected/possible ischemia or infarction in a small area”. Adding AC stress-only images to NC stress-only images reduce the number of unnecessary rest studies substantially

  20. Multimodality Imaging Probe for Positron Emission Tomography and Fluorescence Imaging Studies

    Directory of Open Access Journals (Sweden)

    Suresh K. Pandey

    2014-05-01

    Full Text Available Our goal is to develop multimodality imaging agents for use in cell tracking studies by positron emission tomography (PET and optical imaging (OI. For this purpose, bovine serum albumin (BSA was complexed with biotin (histologic studies, 5(6- carboxyfluorescein, succinimidyl ester (FAM SE (OI studies, and diethylenetriamine pentaacetic acid (DTPA for chelating gallium 68 (PET studies. For synthesis of BSA-biotin-FAM-DTPA, BSA was coupled to (+-biotin N-hydroxysuccinimide ester (biotin-NHSI. BSA- biotin was treated with DTPA-anhydride and biotin-BSA-DTPA was reacted with FAM. The biotin-BSA-DTPA-FAM was reacted with gallium chloride 3 to 5 mCi eluted from the generator using 0.1 N HCl and was passed through basic resin (AG 11 A8 and 150 mCi (100 μL, pH 7–8 was incubated with 0.1 mg of FAM conjugate (100 μL at room temperature for 15 minutes to give 66Ga-BSA-biotin-DTPA-FAM. A shaved C57 black mouse was injected with FAM conjugate (50 μL at one flank and FAM-68Ga (50 μL, 30 mCi at the other. Immediately after injection, the mouse was placed in a fluorescence imaging system (Kodak In-Vivo F, Bruker Biospin Co., Woodbridge, CT and imaged (Λex: 465 nm, Λem: 535 nm, time: 8 seconds, Xenon Light Source, Kodak. The same mouse was then placed under an Inveon microPET scanner (Siemens Medical Solutions, Knoxville, TN injected (intravenously with 25 μCi of 18F and after a half-hour (to allow sufficient bone uptake was imaged for 30 minutes. Molecular weight determined using matrix-associated laser desorption ionization (MALDI for the BSA sample was 66,485 Da and for biotin-BSA was 67,116 Da, indicating two biotin moieties per BSA molecule; for biotin-BSA-DTPA was 81,584 Da, indicating an average of 30 DTPA moieties per BSA molecule; and for FAM conjugate was 82,383 Da, indicating an average of 1.7 fluorescent moieties per BSA molecule. Fluorescence imaging clearly showed localization of FAM conjugate and FAM-68Ga at respective flanks of the mouse

  1. Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA

    Energy Technology Data Exchange (ETDEWEB)

    Hirschmann, Michael T. [Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Department of Orthopaedic Surgery and Traumatology, Bruderholz (Switzerland); Amsler, Felix [Amsler Consulting, Basel (Switzerland); Rasch, Helmut [Kantonsspital Baselland, Institute of Radiology and Nuclear Medicine, Bruderholz (Switzerland)

    2015-11-15

    Bone single photon emission computed tomography (SPECT)/CT is considered as beneficial in unhappy patients with pain, stiffness or swelling after total knee arthroplasty (TKA). The purpose of this study was to identify typical patterns of bone tracer uptake (BTU), distribution and intensity values in patients after TKA. The above findings were correlated with the type and fixation of TKA, the time from TKA and intraoperative findings at revision surgery. A total of 100 knees of 84 consecutive patients (mean age ± SD 70 ± 11 years) after TKA with persistent knee pain were prospectively included. All patients underwent clinical examination, standardized radiographs and {sup 99m}Tc-hydroxymethane diphosphonate (HDP) SPECT/CT as part of a routine diagnostic algorithm. The diagnosis before and after SPECT/CT and final treatment were recorded. TKA component position was determined on 3-D reconstructed images. Intensity and anatomical distribution of BTU was determined. Maximum intensity values were recorded as well as ratios in relation to the proximal midshaft of the femur. Univariate analyses (chi-square test, Pearson's correlation and t test for independent samples) were performed (p < 0.05). SPECT/CT changed the clinical diagnosis and final treatment in 85/100 (85 %) knees. Intraoperative findings confirmed the preoperative SPECT/CT diagnosis in 32/33 knees (97 %). TKA loosening as well as progression of patellofemoral osteoarthritis (OA) was correctly diagnosed in 100 % of knees. Typical patterns of BTU for specific pathologies were identified. Loose femoral TKA components significantly correlated with increased BTU at the lateral femoral regions (p < 0.05). Loose tibial TKA components significantly correlated with increased BTU at all tibial regions (p < 0.05) and around the tibial peg (p > 0.01). The diagnostic benefits of SPECT/CT in patients after TKA have been proven. Typical pathology-related BTU patterns were identified, which will improve reporting

  2. Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA

    International Nuclear Information System (INIS)

    Hirschmann, Michael T.; Amsler, Felix; Rasch, Helmut

    2015-01-01

    Bone single photon emission computed tomography (SPECT)/CT is considered as beneficial in unhappy patients with pain, stiffness or swelling after total knee arthroplasty (TKA). The purpose of this study was to identify typical patterns of bone tracer uptake (BTU), distribution and intensity values in patients after TKA. The above findings were correlated with the type and fixation of TKA, the time from TKA and intraoperative findings at revision surgery. A total of 100 knees of 84 consecutive patients (mean age ± SD 70 ± 11 years) after TKA with persistent knee pain were prospectively included. All patients underwent clinical examination, standardized radiographs and 99m Tc-hydroxymethane diphosphonate (HDP) SPECT/CT as part of a routine diagnostic algorithm. The diagnosis before and after SPECT/CT and final treatment were recorded. TKA component position was determined on 3-D reconstructed images. Intensity and anatomical distribution of BTU was determined. Maximum intensity values were recorded as well as ratios in relation to the proximal midshaft of the femur. Univariate analyses (chi-square test, Pearson's correlation and t test for independent samples) were performed (p < 0.05). SPECT/CT changed the clinical diagnosis and final treatment in 85/100 (85 %) knees. Intraoperative findings confirmed the preoperative SPECT/CT diagnosis in 32/33 knees (97 %). TKA loosening as well as progression of patellofemoral osteoarthritis (OA) was correctly diagnosed in 100 % of knees. Typical patterns of BTU for specific pathologies were identified. Loose femoral TKA components significantly correlated with increased BTU at the lateral femoral regions (p < 0.05). Loose tibial TKA components significantly correlated with increased BTU at all tibial regions (p < 0.05) and around the tibial peg (p > 0.01). The diagnostic benefits of SPECT/CT in patients after TKA have been proven. Typical pathology-related BTU patterns were identified, which will improve reporting quality

  3. Non-invasive imaging of retinal blood flow in myeloproliferative neoplasms

    DEFF Research Database (Denmark)

    Willerslev, Anne; Hansen, Mathias M; Klefter, Oliver Niels

    2017-01-01

    PURPOSE: To study the circulation in the retinal vessels in patients with blood dyscrasia due to myeloproliferative neoplasms using non-invasive retinal imaging. METHODS: Prospective consecutive case series of seven treatment-naïve patients with chronic myeloid leukaemia (n = 2), polycythemia vera...... present at baseline in patients with chronic myeloid leukaemia and were replaced by normal patterns at follow-up. Retinopathy, in the form of cotton-wool spots and retinal haemorrhages, was found at presentation in the two patients with chronic myeloid leukaemia and in one patient with polycythemia vera...

  4. Short-Term Results of Carotid Endarterectomy and Stenting After the Introduction of Carotid Magnetic Resonance Imaging: A Single-Institution Retrospective Study.

    Science.gov (United States)

    Fukumitsu, Ryu; Yoshida, Kazumichi; Kurosaki, Yoshitaka; Torihashi, Koichi; Sadamasa, Nobutake; Koyanagi, Masaomi; Narumi, Osamu; Sato, Tsukasa; Chin, Masaki; Handa, Akira; Yamagata, Sen; Miyamoto, Susumu

    2017-05-01

    Although carotid artery stenting (CAS) has been gaining popularity as an alternative to carotid endarterectomy (CEA), perioperative stroke rate following contemporary CAS remains significantly higher than stroke rate after CEA. The purpose of this study was to assess perioperative (within 30 days) therapeutic results in patients with carotid stenosis (CS) after introduction of preoperative carotid magnetic resonance imaging plaque evaluation in a single center performing both CEA and CAS. Based on prospectively collected data for patients with CS who were scheduled for carotid revascularization, retrospective analysis was conducted of 295 consecutive patients with CS. An intervention was selected after consideration of periprocedural risks for both CEA and CAS. Concerning risk factors for CAS, results of magnetic resonance imaging plaque evaluation were emphasized with a view toward reducing embolic complications. CAS was performed in 114 patients, and CEA was performed in 181 patients. Comparing baseline characteristics of the 295 patients, age, T1 signal intensity of plaque, symptomatic CS, urgent intervention, and diabetes mellitus differed significantly between CAS and CEA groups. Among patients who underwent CAS, new hyperintense lesions on diffusion-weighted imaging were confirmed in 47 patients. New hyperintense lesions on diffusion-weighted imaging were recognized in 21.4% of patients who underwent CEA (n = 39), significantly less frequent than in patients who underwent CAS. The overall short-term outcome of CEA and CAS is acceptable. Preoperative carotid magnetic resonance imaging evaluation of plaque might contribute to low rates of ischemic complications in CAS. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. A generalized model for optimal transport of images including dissipation and density modulation

    KAUST Repository

    Maas, Jan; Rumpf, Martin; Schö nlieb, Carola; Simon, Stefan

    2015-01-01

    transport to strongly dissipative dynamics. For this model a robust and effective variational time discretization of geodesic paths is proposed. This requires to minimize a discrete path energy consisting of a sum of consecutive image matching functionals

  6. Rorschach Inkblot Method data at baseline and after 2 years treatment of consecutively admitted patients with first-episode schizophrenia

    DEFF Research Database (Denmark)

    Rosenbaum, Bent; Andersen, Palle Bent; Knudsen, Per Bjerregaard

    2012-01-01

    Background: The Rorschach Inkblot Method is regarded as an important clinical instrument for detailed diagnostic description of the integrative capacities of individuals in psychotic states and as an instrument for measuring progression in the course of treatment. Aims: To describe relevant...... Rorschach variables at baseline in a group of consecutively admitted patients with first-episode schizophrenia. Furthermore, to describe the changes in these variables from baseline to year 2 for the group of patients given psychiatric standard treatment, and to compare these changes with changes in other...... outcome measures [Positive and Negative Syndrome Scale (PANSS), Global Assessment of Functioning (GAF), Strauss-Carpenter and socio-demographic variables]. Methods: In a prospective study, 34 patients consecutively admitted to treatment for a first episode of schizophrenia were tested using Exner...

  7. A Cognitive Semiotic Study of Students' Reading a Textless Image versus a Verbal Image

    Directory of Open Access Journals (Sweden)

    Roaa Hasan Ali

    2016-10-01

    Full Text Available This study explores fourth year college students'   content   retrieval from reading textless versus verbal images. Furthermore, it examines  the extent to which the respondents comprehend and understand them .The procedures include selecting an image from the internet, designing a written test with its rubrics and exposing it to jury members to ascertain its face validity. The data of this study were analyzed according to the adopted of Peirce's model (1931 of ' icon, index and symbol'. The researchers find out that most of the results were in favor of the verbal images, captions restrict readers' creativity to infer any additional message. Keywords: Content retrieval, Textless images, Verbal images

  8. Injury Incidence in a Spanish Sub-Elite Professional Football Team: A Prospective Study During Four Consecutive Seasons

    Science.gov (United States)

    Mallo, Javier; González, Pablo; Veiga, Santiago; Navarro, Enrique

    2011-01-01

    The aim of this study was to investigate the injury incidence and injury characteristics of a Spanish sub-elite professional football team during four consecutive seasons. A team was followed prospectively from the season 2003-2004 to 2006-2007 and individual player exposure and time loss injuries were recorded during all club training sessions and matches. A total of 313 time-loss injuries were recorded. The mean injury incidence was 10.9 injuries/1000 hours (5.2 injuries/1000 training hours and 44.1 injuries/1000 match hours). The injury incidence during competitive matches was higher (p 28 days absence) was 0.4 injuries/1000 hours. The thigh was the most commonly (35%) injured region and caused 29% of all competitive match absence. Muscle injuries in the four main groups of the lower limbs (hamstrings, adductors, quadriceps and calf muscles) caused 43% of competitive match unavailability. The results of this study show that the risk to sustain a major injury in the course of the season was low for sub- elite footballers in comparison to elite players. Thigh strains were the first cause of absence in competition due to injury. Key points The incidence of major injuries (absence greater than 4 weeks) was lower in a Spanish sub-elite football team than in elite European teams. The risk of sustaining an injury was 2.5 fold higher (p < 0.001) in official than in friendly matches. Lower limb muscular (hamstrings, quadriceps, hip adductors and calf muscles) and joint (knee and ankle) injuries were the main causes of match unavailability. PMID:24149566

  9. SP-ECT imaging and its physical study

    International Nuclear Information System (INIS)

    Kinoshita, Fujimi

    1983-01-01

    Recently, more than a hundred hospitals are provided with SPECT system for clinical examination in Japan. However, a standardization of measuring method and performance test of the systems is ont yet made. We have been studying some basic problems of SPECT system with special phantoms originaly designed by ourselves. We got a conclusion that a standardized phantom is necessary for comparing performances between SPECT systems. In clinical experiences with 3,332 cases, we think that SPECT image combined with conventional image presents much more informations for accurate diagnosis, especially in brain, bone and tumor imagings. Synthesized image of SPECT and XCT, double tracer image and transmission image are useful to visualize the body contour and the clinical diagnosis. (author)

  10. Testicular parenchymal abnormalities in Klinefelter syndrome: a question of cancer? Examination of 40 consecutive patients

    Directory of Open Access Journals (Sweden)

    Giacomo Accardo

    2015-02-01

    Full Text Available Klinefelter syndrome (KS is a hypergonadotropic hypogonadism characterized by a 47, XXY karyotype. The risk of testicular cancer in KS is of interest in relation to theories about testicular cancer etiology generally; nevertheless it seems to be low. We evaluated the need for imaging and serum tumor markers for testicular cancer screening in KS. Participants were 40 consecutive KS patients, enrolled from December 2009 to January 2013. Lactate dehydrogenase (LDH, alpha-fetoprotein (AFP, and beta-human chorionic gonadotrophin subunit (β-HCG serum levels assays and testicular ultrasound (US with color Doppler, were carried out at study entry, after 6 months and every year for 3 years. Abdominal magnetic resonance (MR was performed in KS when testicular US showed micro-calcifications, testicular nodules and cysts. Nearly 62% of the KS had regular testicular echotexture, 37.5% showed an irregular echotexture and 17.5% had micro-calcifications and cysts. Eighty seven percent of KS had a regular vascular pattern, 12.5% varicocele, 12.5% nodules 1 cm. MR ruled out the diagnosis of cancer in all KS with testicular micro calcifications, nodules and cysts. No significant variations in LDH, AFP, and β-HCG levels and in US pattern have been detected during follow-up. We compared serum tumor markers and US pattern between KS with and without cryptorchidism and no statistical differences were found. We did not find testicular cancer in KS, and testicular US, tumor markers and MR were, in selected cases, useful tools for correctly discriminating benign from malignant lesions.

  11. Neuromyelitis optica: a diffusional kurtosis imaging study.

    Science.gov (United States)

    Doring, T M; Lopes, F C R; Kubo, T T A; Tukamoto, G; Kimura, M C; Strecker, R M; Domingues, R C; Gasparetto, E L

    2014-12-01

    Conventional MR imaging typically yields normal images of the brain or indicates lesions in areas of high aquaporin expression in patients with neuromyelitis optica. Diffusional kurtosis imaging was applied in patients with neuromyelitis optica to determine whether this technique could detect alterations in diffusion and diffusional kurtosis parameters in normal-appearing white matter and to explore the relationship between diffusional kurtosis imaging and DTI parameters. Thirteen patients with neuromyelitis optica and 13 healthy controls underwent MR imaging of the brain with conventional and diffusional kurtosis imaging sequences. Tract-based spatial statistics and region-of-interest-based analyses were conducted to identify differences between patients with neuromyelitis optica and controls through conventional DTI and diffusional kurtosis imaging parameters. The parameters were correlated to determine the potential relationship between them. Compared with healthy controls, several diffusional kurtosis imaging and DTI parameters were altered in various fiber tracts of patients with neuromyelitis optica (P optica. We found a negative correlation between diffusional kurtosis imaging (radial kurtosis, axial kurtosis, mean kurtosis) and the corresponding DTI parameters (radial diffusivity, axial diffusivity, mean diffusivity). Positive correlations were found for radial kurtosis and mean kurtosis with fractional anisotropy. This study demonstrated differences in conventional diffusion and diffusional kurtosis parameters, especially radial kurtosis, in the normal-appearing white matter of patients with neuromyelitis optica compared with healthy controls. Larger studies of patients with neuromyelitis optica should be performed to assess the potential clinical impact of these findings. © 2014 by American Journal of Neuroradiology.

  12. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  13. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    International Nuclear Information System (INIS)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe; Fatouraee, Nasser; Saben, Hazhir

    2017-01-01

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes

  14. Ciclon: A neutronic fuel management program for PWR's consecutive cycles

    International Nuclear Information System (INIS)

    Aragones, J.M.

    1977-01-01

    The program description and user's manual of a new computer code is given. Ciclon performs the neutronic calculation of consecutive reload cycles for PWR's fuel management optimization. Fuel characteristics and burnup data, region or batch sizes, loading schemes and state of previously irradiated fuel are input to the code. Cycle lengths or feed enrichments and burnup sharing for each region or batch are calculate using different core neutronic models and printed or punched in standard fuel management format. (author) [es

  15. The results of a consecutive series of dynamic posterior stabilizations using the PercuDyn device.

    Science.gov (United States)

    Canero, Gianfranco; Carbone, Stefano

    2015-11-01

    To evaluate the results of a consecutive series of patients affected by lumbar discogenic pain associated with facet pain and canal stenosis surgically treated with the PercuDyn device. From 2009, 129 consecutive patients (96 M, 33 F, mean age 62) were treated with posterior dynamic stabilization screws (PercuDyn). Inclusion criteria were minimum follow-up of 24 months; pain localized at the lumbar spine column alone or in association to lower limb radicular pain; magnetic resonance evidence of disc degeneration associated with facet degeneration and canal stenosis. Patients were clinically studied using VAS scale and Oswestry Disability Index (ODI); CT assessment of the neuroforamina and spinal canal areas was done at 1 month of follow-up. At 24 months of follow-up, 96 patients fulfilled the inclusion criteria. 96 intervertebral spaces were treated (85 levels L5-S1, 11 levels L4-L5). The VAS scale showed a statistically significant difference at 1 month, 6 months and 2 years with respect to the pre-operative value (p fashion (p return to daily activities. At longer follow-ups, 10 % of patients received revision surgery.

  16. Appearance of choroidal melanoma on high resolution MRI using 1.5 T and a dedicated surface coil in 200 consecutive patients

    International Nuclear Information System (INIS)

    Lemke, A.J.; Hosten, N.; Frenzel, D.; Richter, M.; Felix, R.; Bornfeld, N.; Bechrakis, N.E.

    1998-01-01

    Purpose: Choroidal melanomas usually present a characteristic appearance in MRI. Differing characteristics can cause problems in differential diagnosis between melanomas and other masses in the globe. The purpose of this study was to evaluate the appearance of choroidal melanomas with MRI in a large consecutive patient group. Methods: In a prospective study, 200 patients with choroidal melanomas were investigated with MRI using a 1.5 T scanner and a 5 cm surface coil. Both quantitative and qualitative evaluation of the resulting images was performed. Results: 78.5% of the melanomas presented with homogeneous signal intensities within the tumor due to a homogeneous pigmentation whereas 21.5% of the melanomas demonstrated a mixed pigmentation. Signal intensities of the homogeneous melanomas in the plain T 1 -WI were moderately or markedly hyperintense compared to the vitreous in 29.3% and moderately or markedly hypointense in the T 2 -WI in 37.1%. An accompanying retinal detachment was found in 65.5% and an extraocular growth in 7.0%. Conclusions: In 10% to 37% we observed the typical well known MR appearance, including homogenous high signal in the T 1 -WI and low signals in the T 2 -WI. For further differentiation, morphological criteria (e.g. shape, size, and position) were used, which are also discussed. (orig.) [de

  17. Image registration based on virtual frame sequence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H.; Ng, W.S. [Nanyang Technological University, Computer Integrated Medical Intervention Laboratory, School of Mechanical and Aerospace Engineering, Singapore (Singapore); Shi, D. (Nanyang Technological University, School of Computer Engineering, Singapore, Singpore); Wee, S.B. [Tan Tock Seng Hospital, Department of General Surgery, Singapore (Singapore)

    2007-08-15

    This paper is to propose a new framework for medical image registration with large nonrigid deformations, which still remains one of the biggest challenges for image fusion and further analysis in many medical applications. Registration problem is formulated as to recover a deformation process with the known initial state and final state. To deal with large nonlinear deformations, virtual frames are proposed to be inserted to model the deformation process. A time parameter is introduced and the deformation between consecutive frames is described with a linear affine transformation. Experiments are conducted with simple geometric deformation as well as complex deformations presented in MRI and ultrasound images. All the deformations are characterized with nonlinearity. The positive results demonstrated the effectiveness of this algorithm. The framework proposed in this paper is feasible to register medical images with large nonlinear deformations and is especially useful for sequential images. (orig.)

  18. Role of chelates in magnetic resonance imaging studies

    Directory of Open Access Journals (Sweden)

    Tripathi Laxmi

    2009-01-01

    Full Text Available Imaging studies are tests performed with a variety of techniques that produce pictures of the inside of a patient′s body. Magnetic resonance imaging (MRI is an imaging technique based on the principles of nuclear magnetic resonance. MRI uses a powerful magnetic field, radio waves, and a computer to produce detailed pictures of organs, soft tissues, bone, and virtually all other internal body structures. Chelates have a wide application in such imaging techniques. Chelates in imaging studies are used alone as radioactive agents or conjugated to monoclonal antibodies or to DNA as radioactive agents. Technetium chelates and gadolinium chelates are being widely used as magnetic resonance contrast media.

  19. Alveolar Ridge Contouring with Free Connective Tissue Graft at Implant Placement: A 5-Year Consecutive Clinical Study.

    Science.gov (United States)

    Hanser, Thomas; Khoury, Fouad

    2016-01-01

    This study evaluated volume stability after alveolar ridge contouring with free connective tissue grafts at implant placement in single-tooth gaps. A total of 52 single-tooth gaps with labial volume deficiencies in the maxilla (incisors, canines, and premolars) were consecutively treated with implants and concomitant free palatal connective tissue grafts in 46 patients between 2006 and 2009. Implants had to be covered with at least 2 mm peri-implant local bone after insertion. At implant placement, a free connective tissue graft from the palate was fixed inside a labial split-thickness flap to form an existing concave buccal alveolar ridge contour due to tissue volume deficiency into a convex shape. Standardized volumetric measurements of the labial alveolar contour using a template were evaluated before connective tissue grafting and at 2 weeks, 1 year, and 5 years after implantprosthetic incorporation. Tissue volume had increased significantly (P tissue contour of the implant before connective tissue grafting to baseline (2 weeks after implant-prosthetic incorporation). Statistically, 50% of the reference points (P > .05) kept their volume from baseline to 1 year after prosthetic incorporation and from baseline to 5 years after prosthetic incorporation, respectively, whereas reference points located within the area of the implant sulcus showed a significant (P connective tissue grafting appears to be an appropriate long-term means to contour preexisting buccal alveolar volume deficiencies in single implants.

  20. Comparison of acoustic radiation force impulse imaging (ARFI) to liver biopsy histologic scores in the evaluation of chronic liver disease: A pilot study.

    Science.gov (United States)

    Haque, Mazhar; Robinson, Charlotte; Owen, David; Yoshida, Eric M; Harris, Alison

    2010-01-01

    Acoustic Radiation Force Impulse Imaging (ARFI) is a novel non invasive technique studying the localized mechanical properties of tissue by utilising short, high intensity acoustic pulses (shear wave pulses) to assess the mechanical response (tissue displacement), providing a measure of tissue elasticity. The aim of this study is to investigate the feasibility of ARFI imaging as a non-invasive method for the assessment of liver fibrosis compared to liver biopsy scores. A prospective blind comparison study of ARFI elastography (Virtual Touch Imaging., ACUSON S2000 Ultrasound Unit, Siemens, Mountain View CA) in a consecutive series of patients who underwent liver biopsy for assessment of fibrosis in chronic liver disease. ARFI shear-wave propagation velocity was measured in meters per second. Mean ARFI velocities were compared with both Batts-Ludwig (F0 to F4) and Modified Ishak scores (F0 to F4) for fibrosis in liver biopsy findings. Twenty-one patients with chronic liver disease (Hepatitis C (HCV) =16, Hepatitis B (HBV) = 1, both HCV and HBV = 1 Alcoholic liver disease (ALD) = 1, others = 2) underwent ARFI and liver biopsy on the same day. The Spearman correlation coefficients between the median values of the ARFI measurements and the histological fibrosis stage of the Modified Ishak score and Batts-Lud- (3) wig score were both highly significant (p shak score in chronic liver disease. It.s accuracy in prediction of severe fibrosis and cirrhosis is maximal in comparison with earlier stages.

  1. Optimisation of the digital radiographic imaging of suspected non-accidental injury

    Science.gov (United States)

    Offiah, Amaka

    Aim: To optimise the digital (radiographic) imaging of children presenting with suspected non-accidental injury (NAI). Objectives: (i) To evaluate existing radiographic quality criteria, and to develop a more suitable system if these are found to be inapplicable to skeletal surveys obtained in suspected NAI. (ii) To document differences in image quality between conventional film-screen and the recently installed Fuji5000R computed radiography (CR) system at Great Ormond Street Hospital for Children, (iii) To document the extent of variability in the standard of skeletal surveys obtained in the UK for suspected NAI. (iv) To determine those radiographic parameters which yield the highest diagnostic accuracy, while still maintaining acceptable radiation dose to the child, (v) To determine how varying degrees of edge-enhancement affect diagnostic accuracy. (vi) To establish the accuracy of soft compared to hard copy interpretation of images in suspected NAI. Materials and Methods: (i) and (ii) Retrospective analysis of 286 paediatric lateral spine radiographs by two observers based on the Commission of European Communities (CEC) quality criteria, (iii) Review of the skeletal surveys of 50 consecutive infants referred from hospitals throughout the United Kingdom (UK) with suspected NAI. (iv) Phantom studies. Leeds TO. 10 and TO. 16 test objects were used to compare the relationship between film density, exposure parameters and visualisation of object details, (iv) Clinical study. Anteroposterior and lateral post mortem skull radiographs of six consecutive infants were obtained at various exposures. Six observers independently scored the images based on visualisation of five criteria, (v) and (vi) A study of diagnostic accuracy in which six observers independently interpreted 50 radiographs from printed copies (with varying degrees of edge-enhancement) and from a monitor. Results: The CEC criteria are useful for optimisation of imaging parameters and allow the detection

  2. Image noise reduction algorithm for digital subtraction angiography: clinical results.

    Science.gov (United States)

    Söderman, Michael; Holmin, Staffan; Andersson, Tommy; Palmgren, Charlotta; Babic, Draženko; Hoornaert, Bart

    2013-11-01

    To test the hypothesis that an image noise reduction algorithm designed for digital subtraction angiography (DSA) in interventional neuroradiology enables a reduction in the patient entrance dose by a factor of 4 while maintaining image quality. This clinical prospective study was approved by the local ethics committee, and all 20 adult patients provided informed consent. DSA was performed with the default reference DSA program, a quarter-dose DSA program with modified acquisition parameters (to reduce patient radiation dose exposure), and a real-time noise-reduction algorithm. Two consecutive biplane DSA data sets were acquired in each patient. The dose-area product (DAP) was calculated for each image and compared. A randomized, blinded, offline reading study was conducted to show noninferiority of the quarter-dose image sets. Overall, 40 samples per treatment group were necessary to acquire 80% power, which was calculated by using a one-sided α level of 2.5%. The mean DAP with the quarter-dose program was 25.3% ± 0.8 of that with the reference program. The median overall image quality scores with the reference program were 9, 13, and 12 for readers 1, 2, and 3, respectively. These scores increased slightly to 12, 15, and 12, respectively, with the quarter-dose program imaging chain. In DSA, a change in technique factors combined with a real-time noise-reduction algorithm will reduce the patient entrance dose by 75%, without a loss of image quality. RSNA, 2013

  3. The importance of early arthroscopy in athletes with painful cartilage lesions of the ankle: a prospective study of 61 consecutive cases

    Directory of Open Access Journals (Sweden)

    Riyami Masoud

    2006-09-01

    Full Text Available Abstract Background Ankle sprains are common in sports and can sometimes result in a persistent pain condition. Purpose Primarily to evaluate clinical symptoms, signs, diagnostics and outcomes of surgery for symptomatic chondral injuries of the talo crural joint in athletes. Secondly, in applicable cases, to evaluate the accuracy of MRI in detecting these injuries. Type of study: Prospective consecutive series. Methods Over around 4 years we studied 61 consecutive athletes with symptomatic chondral lesions to the talocrural joint causing persistent exertion ankle pain. Results 43% were professional full time athletes and 67% were semi-professional, elite or amateur athletes, main sports being soccer (49% and rugby (14%. The main subjective complaint was exertion ankle pain (93%. Effusion (75% and joint line tenderness on palpation (92% were the most common clinical findings. The duration from injury to arthroscopy for 58/61 cases was 7 months (5.7–7.9. 3/61 cases were referred within 3 weeks from injury. There were in total 75 cartilage lesions. Of these, 52 were located on the Talus dome, 17 on the medial malleolus and 6 on the Tibia plafond. Of the Talus dome injuries 18 were anteromedial, 14 anterolateral, 9 posteromedial, 3 posterolateral and 8 affecting mid talus. 50% were grade 4 lesions, 13.3% grade 3, 16.7% grade 2 and 20% grade 1. MRI had been performed pre operatively in 26/61 (39% and 59% of these had been interpreted as normal. Detection rate of cartilage lesions was only 19%, but subchondral oedema was present in 55%. At clinical follow up average 24 months after surgery (10–48 months, 73% were playing at pre-injury level. The average return to that level of sports after surgery was 16 weeks (3–32 weeks. However 43% still suffered minor symptoms. Conclusion Arthroscopy should be considered early when an athlete presents with exertion ankle pain, effusion and joint line tenderness on palpation after a previous sprain

  4. Diagnosing cysts with correlation coefficient images from 2-dimensional freehand elastography.

    Science.gov (United States)

    Booi, Rebecca C; Carson, Paul L; O'Donnell, Matthew; Richards, Michael S; Rubin, Jonathan M

    2007-09-01

    We compared the diagnostic potential of using correlation coefficient images versus elastograms from 2-dimensional (2D) freehand elastography to characterize breast cysts. In this preliminary study, which was approved by the Institutional Review Board and compliant with the Health Insurance Portability and Accountability Act, we imaged 4 consecutive human subjects (4 cysts, 1 biopsy-verified benign breast parenchyma) with freehand 2D elastography. Data were processed offline with conventional 2D phase-sensitive speckle-tracking algorithms. The correlation coefficient in the cyst and surrounding tissue was calculated, and appearances of the cysts in the correlation coefficient images and elastograms were compared. The correlation coefficient in the cysts was considerably lower (14%-37%) than in the surrounding tissue because of the lack of sufficient speckle in the cysts, as well as the prominence of random noise, reverberations, and clutter, which decorrelated quickly. Thus, the cysts were visible in all correlation coefficient images. In contrast, the elastograms associated with these cysts each had different elastographic patterns. The solid mass in this study did not have the same high decorrelation rate as the cysts, having a correlation coefficient only 2.1% lower than that of surrounding tissue. Correlation coefficient images may produce a more direct, reliable, and consistent method for characterizing cysts than elastograms.

  5. Laser-induced photo-thermal strain imaging

    Science.gov (United States)

    Choi, Changhoon; Ahn, Joongho; Jeon, Seungwan; Kim, Chulhong

    2018-02-01

    Vulnerable plaque is the one of the leading causes of cardiovascular disease occurrence. However, conventional intravascular imaging techniques suffer from difficulty in finding vulnerable plaque due to limitation such as lack of physiological information, imaging depth, and depth sensitivity. Therefore, new techniques are needed to help determine the vulnerability of plaque, Thermal strain imaging (TSI) is an imaging technique based on ultrasound (US) wave propagation speed that varies with temperature of medium. During temperature increase, strain occurs in the medium and its variation tendency is depending on the type of tissue, which makes it possible to use for tissue differentiation. Here, we demonstrate laser-induced photo-thermal strain imaging (pTSI) to differentiate tissue using an intravascular ultrasound (IVUS) catheter and a 1210-nm continuous-wave laser for heating lipids intensively. During heating, consecutive US images were obtained from a custom-made phantom made of porcine fat and gelatin. A cross correlation-based speckle-tracking algorithm was then applied to calculate the strain of US images. In the strain images, the positive strain produced in lipids (porcine fat) was clearly differentiated from water-bearing tissue (gelatin). This result shows that laser-induced pTSI could be a new method to distinguish lipids in the plaque and can help to differentiate vulnerability of plaque.

  6. How Accurately Do Consecutive Cohort Audits Predict Phase III Multisite Clinical Trial Recruitment in Palliative Care?

    Science.gov (United States)

    McCaffrey, Nikki; Fazekas, Belinda; Cutri, Natalie; Currow, David C

    2016-04-01

    Audits have been proposed for estimating possible recruitment rates to randomized controlled trials (RCTs), but few studies have compared audit data with subsequent recruitment rates. To compare the accuracy of estimates of potential recruitment from a retrospective consecutive cohort audit of actual participating sites and recruitment to four Phase III multisite clinical RCTs. The proportion of potentially eligible study participants estimated from an inpatient chart review of people with life-limiting illnesses referred to six Australian specialist palliative care services was compared with recruitment data extracted from study prescreening information from three sites that participated fully in four Palliative Care Clinical Studies Collaborative RCTs. The predominant reasons for ineligibility in the audit and RCTs were analyzed. The audit overestimated the proportion of people referred to the palliative care services who could participate in the RCTs (pain 17.7% vs. 1.2%, delirium 5.8% vs. 0.6%, anorexia 5.1% vs. 0.8%, and bowel obstruction 2.8% vs. 0.5%). Approximately 2% of the referral base was potentially eligible for these effectiveness studies. Ineligibility for general criteria (language, cognition, and geographic proximity) varied between studies, whereas the reasons for exclusion were similar between the audit and pain and anorexia studies but not for delirium or bowel obstruction. The retrospective consecutive case note audit in participating sites did not predict realistic recruitment rates, mostly underestimating the impact of study-specific inclusion criteria. These findings have implications for the applicability of the results of RCTs. Prospective pilot studies are more likely to predict actual recruitment. Copyright © 2016 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  7. Making cytological diagnoses on digital images using the iPath network.

    Science.gov (United States)

    Dalquen, Peter; Savic Prince, Spasenija; Spieler, Peter; Kunze, Dietmar; Neumann, Heinrich; Eppenberger-Castori, Serenella; Adams, Heiner; Glatz, Katharina; Bubendorf, Lukas

    2014-01-01

    The iPath telemedicine platform Basel is mainly used for histological and cytological consultations, but also serves as a valuable learning tool. To study the level of accuracy in making diagnoses based on still images achieved by experienced cytopathologists, to identify limiting factors, and to provide a cytological image series as a learning set. Images from 167 consecutive cytological specimens of different origin were uploaded on the iPath platform and evaluated by four cytopathologists. Only wet-fixed and well-stained specimens were used. The consultants made specific diagnoses and categorized each as benign, suspicious or malignant. For all consultants, specificity and sensitivity regarding categorized diagnoses were 83-92 and 85-93%, respectively; the overall accuracy was 88-90%. The interobserver agreement was substantial (κ = 0.791). The lowest rate of concordance was achieved in urine and bladder washings and in the identification of benign lesions. Using a digital image set for diagnostic purposes implies that even under optimal conditions the accuracy rate will not exceed to 80-90%, mainly because of lacking supportive immunocytochemical or molecular tests. This limitation does not disqualify digital images for teleconsulting or as a learning aid. The series of images used for the study are open to the public at http://pathorama.wordpress.com/extragenital-cytology-2013/. © 2014 S. Karger AG, Basel.

  8. Theoretical analysis of consecutive reactions in adiabatic stirred tank reactors

    International Nuclear Information System (INIS)

    Jo, Byung Wook; Kim, Sun Il; Hong, Won Hae; Cha, Wol Suk; Kim, Soong Pyung; Kim, Jung Gyu

    1990-01-01

    By mathematical model for the case of the consecutive first-order exothermic reaction in an adiabatic CSTR, the effects of the system parameter i. e. relative residence time, heat of reaction and thermal sensitivity of reaction rate constant, on the concentration profile of the intermediate product of a consecutive reaction were obtained as follows. For fixed values of the ratio of the reaction rate constants t 1 / t 2 , the ratio of the correponding system parameter α where α>1 and the sensitivities of the reaction rate constants S1 and S2, the maximum value of the intermediate production dimensionless concentration increases with increase in the values of the relative energy parameter E1 and E2 and it decreases with a decrease in E1 and E2. For fixed values of the ratio of the reaction rate constants t 1 / t 2 , the ratio of the corresponding system parameter α where α 1 and t 2 and it increases with a decrease in S1 and S2. For fixed values of the ratio of the reaction rate constants t 1 / t 2 , the ratio of the corresponding system parameters α where α=1 and the relative energy parameters E1 and E2, the maximum value of the intermediate product dimensionless is constant with either increase or decrease in the sensitivities of the reaction rate constants S1 and S2. (Author)

  9. Magnetic resonance imaging findings in patients with peroneal tendinopathy and peroneal tenosynovitis

    International Nuclear Information System (INIS)

    Kijowski, Richard; Smet, Arthur de; Mukharjee, Rajat

    2007-01-01

    To compare the magnetic resonance (MR) imaging findings of a group of patients with clinically diagnosed peroneal tendonopathy and peroneal tenosynovitis with the MR imaging findings of a control group of patients with no clinical evidence of peroneal tendon disorder. The MR examinations of 24 patients with symptomatic peroneal tendinopathy or peroneal tenosynovitis and 70 patients with no clinical evidence of peroneal tendon disorder were retrospectively reviewed to determine the presence or absence of four MR imaging findings: 1) predominantly or uniform intermediate signal intensity within the peroneal tendons on one or more axial proton density-weighted images, 2) predominantly or uniform intermediate signal intensity within the peroneal tendons on three consecutive axial proton density-weighted images, 3) intermediate T2 signal intensity within the peroneal tendons, and 4) circumferential fluid within the common peroneal tendon sheath greater than 3 mm in maximal width. The sensitivity and specificity of these MR imaging findings for determining the presence or absence or symptomatic peroneal tendinopathy or peroneal tenosynovitis were calculated. The sensitivity of MR imaging findings 1, 2, 3, and 4 for determining the presence of peroneal tendinopathy or peroneal tenosynovitis were 92%, 92%, 50%, and 17% respectively. The specificity of MR imaging findings 1, 2, 3, and 4 for determining the absence of peroneal tendinopathy or peroneal tenosynovitis were 57%, 79%, 93%, and 100% respectively. The presence of predominantly or uniform intermediate signal intensity within the peroneal tendons on three consecutive axial proton density-weighted images is a highly sensitive and moderately specific indicator of symptomatic peroneal tendinopathy. The presence of intermediate T2 signal within the peroneal tendons, and the presence of circumferential fluid within the peroneal tendon sheath greater than 3 mm in maximal width, are highly specific indicators of peroneal

  10. Magnetic resonance imaging findings in patients with peroneal tendinopathy and peroneal tenosynovitis

    Energy Technology Data Exchange (ETDEWEB)

    Kijowski, Richard; Smet, Arthur de [University of Wisconsin Hospital, Department of Radiology, Madison, WI (United States); Mukharjee, Rajat [University of Wisconsin Hospital, Department of Radiology, Madison, WI (United States); University of Wisconsin Hospital, Department of Statistics, Madison, WI (United States)

    2007-02-15

    To compare the magnetic resonance (MR) imaging findings of a group of patients with clinically diagnosed peroneal tendonopathy and peroneal tenosynovitis with the MR imaging findings of a control group of patients with no clinical evidence of peroneal tendon disorder. The MR examinations of 24 patients with symptomatic peroneal tendinopathy or peroneal tenosynovitis and 70 patients with no clinical evidence of peroneal tendon disorder were retrospectively reviewed to determine the presence or absence of four MR imaging findings: 1) predominantly or uniform intermediate signal intensity within the peroneal tendons on one or more axial proton density-weighted images, 2) predominantly or uniform intermediate signal intensity within the peroneal tendons on three consecutive axial proton density-weighted images, 3) intermediate T2 signal intensity within the peroneal tendons, and 4) circumferential fluid within the common peroneal tendon sheath greater than 3 mm in maximal width. The sensitivity and specificity of these MR imaging findings for determining the presence or absence or symptomatic peroneal tendinopathy or peroneal tenosynovitis were calculated. The sensitivity of MR imaging findings 1, 2, 3, and 4 for determining the presence of peroneal tendinopathy or peroneal tenosynovitis were 92%, 92%, 50%, and 17% respectively. The specificity of MR imaging findings 1, 2, 3, and 4 for determining the absence of peroneal tendinopathy or peroneal tenosynovitis were 57%, 79%, 93%, and 100% respectively. The presence of predominantly or uniform intermediate signal intensity within the peroneal tendons on three consecutive axial proton density-weighted images is a highly sensitive and moderately specific indicator of symptomatic peroneal tendinopathy. The presence of intermediate T2 signal within the peroneal tendons, and the presence of circumferential fluid within the peroneal tendon sheath greater than 3 mm in maximal width, are highly specific indicators of peroneal

  11. Study of Three-Dimensional Image Brightness Loss in Stereoscopy

    Directory of Open Access Journals (Sweden)

    Hsing-Cheng Yu

    2015-10-01

    Full Text Available When viewing three-dimensional (3D images, whether in cinemas or on stereoscopic televisions, viewers experience the same problem of image brightness loss. This study aims to investigate image brightness loss in 3D displays, with the primary aim being to quantify the image brightness degradation in the 3D mode. A further aim is to determine the image brightness relationship to the corresponding two-dimensional (2D images in order to adjust the 3D-image brightness values. In addition, the photographic principle is used in this study to measure metering values by capturing 2D and 3D images on television screens. By analyzing these images with statistical product and service solutions (SPSS software, the image brightness values can be estimated using the statistical regression model, which can also indicate the impact of various environmental factors or hardware on the image brightness. In analysis of the experimental results, comparison of the image brightness between 2D and 3D images indicates 60.8% degradation in the 3D image brightness amplitude. The experimental values, from 52.4% to 69.2%, are within the 95% confidence interval

  12. Fine focal spot size improves image quality in computed tomography abdomen and pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Goh, Yin P.; Low, Keat; Kuganesan, Ahilan [Monash Health, Diagnostic Imaging Department, 246, Clayton Road, Clayton, Victoria (Australia); Lau, Kenneth K. [Monash Health, Diagnostic Imaging Department, 246, Clayton Road, Clayton, Victoria (Australia); Monash University, Department of Medicine, Faculty of Medicine, Nursing and Health Sciences, Victoria (Australia); Buchan, Kevin [Philips Healthcare, Clinical Science, PO Box 312, Mont Albert, Victoria (Australia); Oh, Lawrence Chia Wei [Flinders Medical Centre, Division of Medical Imaging, Bedford Park South (Australia); Huynh, Minh [Swinburne University, Department of Statistics, Data Science and Epidemiology, School of Health Sciences, Faculty of Health, Arts and Design, Hawthorn (Australia)

    2016-12-15

    To compare the image quality between fine focal spot size (FFSS) and standard focal spot size (SFSS) in computed tomography of the abdomen and pelvis (CTAP) This retrospective review included all consecutive adult patients undergoing contrast-enhanced CTAP between June and September 2014. Two blinded radiologists assessed the margin clarity of the abdominal viscera and the detected lesions using a five-point grading scale. Cohen's kappa test was used to examine the inter-observer reliability between the two reviewers for organ margin clarity. Mann-Whitney U testing was utilised to assess the statistical difference of the organ and lesion margin clarity. 100 consecutive CTAPs were recruited. 52 CTAPs were examined with SFSS of 1.1 x 1.2 mm and 48 CTAPs were examined with FFSS of 0.6 x 0.7 mm. Results showed that there was substantial agreement for organ margin clarity (mean κ = 0.759, p < 0.001) among the reviewers. FFSS produces images with clearer organ margins (U = 76194.0, p < 0.001, r = 0.523) and clearer lesion margins (U = 239, p = 0.052, r = 0.269). FFSS CTAP improves image quality in terms of better organ and lesion margin clarity. Fine focus CT scanning is a novel technique that may be applied in routine CTAP imaging. (orig.)

  13. Comparative study of ultrasound imaging, computed tomography and magnetic resonance imaging in gynecology

    International Nuclear Information System (INIS)

    Ishii, Kenji; Kobayashi, Hisaaki; Hoshihara, Takayuki; Kobayashi, Mitsunao; Suda, Yoshio; Takenaka, Eiichi; Sasa, Hidenori.

    1989-01-01

    We studied 18 patients who were operated at the National Defense Medical College Hospital and confirmed by pathological diagnosis. We compared ultrasound imaging, computed tomography (CT) and magnetic resonance imaging (MRI) of the patients. MRI was useful to diagnose enlargement of the uterine cavity and a small amount of ascites and to understand orientation of the pelvic organs. Ultrasound imaging is the most useful examination to diagnose gynecological diseases. But when it is difficult to diagnose by ultrasound imaging alone, we should employ either CT or MRI, or preferably both. (author)

  14. Effect of pitching consecutive days in youth softball tournaments on objective shoulder strength and subjective shoulder symptoms

    Science.gov (United States)

    Skillington, S. Andrew; Brophy, Robert H.; Wright, Rick W.; Smith, Matthew V.

    2017-01-01

    Background The windmill pitching motion has been associated with risk for shoulder injury. Since there are no pitching limits on youth fast-pitch softball pitchers, these athletes often pitch multiple games across consecutive days. Strength changes, fatigue levels, and shoulder pain that develop among female fast-pitch pitchers over the course of consecutive days of pitching have not been investigated. Hypothesis Over the course of 2 and 3-day fast-pitch softball tournaments, pitchers will develop progressive objective weakness and increased subjective shoulder fatigue and pain without complete recovery between days. Study Design Cross-Sectional Study. Methods Female fast-pitch softball pitchers between the ages of 14 and 18 who were pitching in 2 and 3-day tournaments were recruited for study participation. At the beginning and end of each day of tournament play, pitchers were asked to quantify shoulder fatigue and shoulder pain levels of their dominant throwing arm using a 10-point visual analog scale (VAS). Shoulder abduction, flexion, external rotation, internal rotation, elbow flexion, and elbow extension strength measurements were gathered using a hand-held dynamometer. Results Over the course of an average single day of tournament participation, pitchers developed significant increases in VAS shoulder fatigue (2.0, 95% CI: 1.3 to 3.0), and pain (1.3, 95% CI: 0.5 to 2.3) and significant strength loss in all tested motions. Pitchers also developed significant increases in VAS shoulder fatigue (3.5, 95% CI: 1.5 to 5.5), VAS shoulder pain (2.5, 95% CI: 1.0 to 4.5) and strength loss in all tested motions over the entire tournament. Shoulder pain, fatigue, and strength do not fully recover between days. The accumulation of subjective shoulder pain and fatigue over the course of tournament play were closely correlated. Conclusion Among youth female fast-pitch softball pitchers, there is a progressive increase in shoulder fatigue, pain, and weakness over the course

  15. BI-RADS categorisation of 2708 consecutive nonpalpable breast lesions in patients referred to a dedicated breast care unit

    International Nuclear Information System (INIS)

    Hamy, A.S.; Giacchetti, S.; Cuvier, C.; Perret, F.; Bonfils, S.; Charveriat, P.; Hocini, H.; Espie, M.; Albiter, M.; Bazelaire, C. de; Roquancourt, A. de

    2012-01-01

    To determine the malignancy rate of nonpalpable breast lesions, categorised according to the Breast Imaging Reporting and Data System (BI-RADS) classification in the setting of a Breast Care Unit. All nonpalpable breast lesions from consecutive patients referred to a dedicated Breast Care Unit were prospectively reviewed and classified into 5 BI-RADS assessment categories (0, 2, 3, 4, and 5). A total of 2708 lesions were diagnosed by mammography (71.6%), ultrasound (8.7%), mammography and ultrasound (19.5%), or MRI (0.2%). The distribution of the lesions by BI-RADS category was: 152 in category 0 (5.6%), 56 in category 2 (2.1%), 742 in category 3 (27.4%), 1523 in category 4 (56.2%) and 235 in category 5 (8.7%). Histology revealed 570 malignant lesions (32.9%), 152 high-risk lesions (8.8%), and 1010 benign lesions (58.3%). Malignancy was detected in 17 (2.3%) category 3 lesions, 364 (23.9%) category 4 lesions and 185 (78.7%) category 5 lesions. Median follow-up was 36.9 months. This pragmatic study reflects the assessment and management of breast impalpable abnormalities referred for care to a specialized Breast Unit. Multidisciplinary evaluation with BI-RADS classification accurately predicts malignancy, and reflects the quality of management. This assessment should be encouraged in community practice appraisal. (orig.)

  16. Fast Blood Vector Velocity Imaging: Simulations and Preliminary In Vivo Results

    DEFF Research Database (Denmark)

    Udesen, Jesper; Gran, Fredrik; Hansen, Kristoffer Lindskov

    2007-01-01

    for each pulse emission. 2) The transmitted pulse consists of a 13 bit Barker code which is transmitted simultaneously from each transducer element. 3) The 2-D vector velocity of the blood is found using 2-D speckle tracking between segments in consecutive speckle images. III Results: The method was tested...

  17. Patient-specific 3D models created by 3D imaging system or bi-planar imaging coupled with Moiré-Fringe projections: a comparative study of accuracy and reliability on spinal curvatures and vertebral rotation data.

    Science.gov (United States)

    Hocquelet, Arnaud; Cornelis, François; Jirot, Anna; Castaings, Laurent; de Sèze, Mathieu; Hauger, Olivier

    2016-10-01

    The aim of this study is to compare the accuracy and reliability of spinal curvatures and vertebral rotation data based on patient-specific 3D models created by 3D imaging system or by bi-planar imaging coupled with Moiré-Fringe projections. Sixty-two consecutive patients from a single institution were prospectively included. For each patient, frontal and sagittal calibrated low-dose bi-planar X-rays were performed and coupled simultaneously with an optical Moiré back surface-based technology. The 3D reconstructions of spine and pelvis were performed independently by one radiologist and one technician in radiology using two different semi-automatic methods using 3D radio-imaging system (method 1) or bi-planar imaging coupled with Moiré projections (method 2). Both methods were compared using Bland-Altman analysis, and reliability using intraclass correlation coefficient (ICC). ICC showed good to very good agreement. Between the two techniques, the maximum 95 % prediction limits was -4.9° degrees for the measurements of spinal coronal curves and less than 5° for other parameters. Inter-rater reliability was excellent for all parameters across both methods, except for axial rotation with method 2 for which ICC was fair. Method 1 was faster for reconstruction time than method 2 for both readers (13.4 vs. 20.7 min and 10.6 vs. 13.9 min; p = 0.0001). While a lower accuracy was observed for the evaluation of the axial rotation, bi-planar imaging coupled with Moiré-Fringe projections may be an accurate and reliable tool to perform 3D reconstructions of the spine and pelvis.

  18. Detection of large-scale concentric gravity waves from a Chinese airglow imager network

    Science.gov (United States)

    Lai, Chang; Yue, Jia; Xu, Jiyao; Yuan, Wei; Li, Qinzeng; Liu, Xiao

    2018-06-01

    Concentric gravity waves (CGWs) contain a broad spectrum of horizontal wavelengths and periods due to their instantaneous localized sources (e.g., deep convection, volcanic eruptions, or earthquake, etc.). However, it is difficult to observe large-scale gravity waves of >100 km wavelength from the ground for the limited field of view of a single camera and local bad weather. Previously, complete large-scale CGW imagery could only be captured by satellite observations. In the present study, we developed a novel method that uses assembling separate images and applying low-pass filtering to obtain temporal and spatial information about complete large-scale CGWs from a network of all-sky airglow imagers. Coordinated observations from five all-sky airglow imagers in Northern China were assembled and processed to study large-scale CGWs over a wide area (1800 km × 1 400 km), focusing on the same two CGW events as Xu et al. (2015). Our algorithms yielded images of large-scale CGWs by filtering out the small-scale CGWs. The wavelengths, wave speeds, and periods of CGWs were measured from a sequence of consecutive assembled images. Overall, the assembling and low-pass filtering algorithms can expand the airglow imager network to its full capacity regarding the detection of large-scale gravity waves.

  19. MR imaging features of foot involvement in patients with psoriasis

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, C. Zuhal [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey)], E-mail: sunarerdem@yahoo.com; Tekin, Nilgun Solak [Department of Dermatology, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey); Sarikaya, Selda [Department of Physical Therapy and Rehabilitation, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey); Erdem, L. Oktay; Gulec, Sezen [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey)

    2008-09-15

    Objective: To determine alterations of the soft tissues, tendons, cartilage, joint spaces, and bones of the foot using magnetic resonance (MR) imaging in patients with psoriasis. Materials and methods: Clinical and MR examination of the foot was performed in 26 consecutive patients (52 ft) with psoriasis. As a control group, 10 healthy volunteers (20 ft) were also studied. Joint effusion/synovitis, retrocalcaneal bursitis, retroachilles bursitis, Achilles tendonitis, soft-tissue edema, para-articular enthesophytes, bone marrow edema, sinus tarsi syndrome, enthesopathy at the Achilles attachment and at the plantar fascia attachment, plantar fasciitis, tenosynovitis, subchondral cysts, and bone erosions, joint space narrowing, subchondral signal changes, osteolysis, luxation, and sub-luxation were examined. Results: Clinical signs and symptoms (pain and swelling) due to foot involvement were present in none of the patients while frequency of involvement was 92% (24/26) by MR imaging. The most common MR imaging findings were Achilles tendonitis (acute and peritendinitis) (57%), retrocalcaneal bursitis (50%), joint effusion/synovitis (46%), soft-tissue edema (46%), and para-articular enthesophytes (38%). The most commonly involved anatomical region was the hindfoot (73%). Conclusion: Our data showed that the incidence of foot involvement was very high in asymptomatic patients with psoriasis on MR imaging. Further MR studies are needed to confirm these data. We conclude that MR imaging may be of importance especially in early diagnosis and treatment of inflammatory changes in the foot.

  20. MR imaging features of foot involvement in patients with psoriasis

    International Nuclear Information System (INIS)

    Erdem, C. Zuhal; Tekin, Nilgun Solak; Sarikaya, Selda; Erdem, L. Oktay; Gulec, Sezen

    2008-01-01

    Objective: To determine alterations of the soft tissues, tendons, cartilage, joint spaces, and bones of the foot using magnetic resonance (MR) imaging in patients with psoriasis. Materials and methods: Clinical and MR examination of the foot was performed in 26 consecutive patients (52 ft) with psoriasis. As a control group, 10 healthy volunteers (20 ft) were also studied. Joint effusion/synovitis, retrocalcaneal bursitis, retroachilles bursitis, Achilles tendonitis, soft-tissue edema, para-articular enthesophytes, bone marrow edema, sinus tarsi syndrome, enthesopathy at the Achilles attachment and at the plantar fascia attachment, plantar fasciitis, tenosynovitis, subchondral cysts, and bone erosions, joint space narrowing, subchondral signal changes, osteolysis, luxation, and sub-luxation were examined. Results: Clinical signs and symptoms (pain and swelling) due to foot involvement were present in none of the patients while frequency of involvement was 92% (24/26) by MR imaging. The most common MR imaging findings were Achilles tendonitis (acute and peritendinitis) (57%), retrocalcaneal bursitis (50%), joint effusion/synovitis (46%), soft-tissue edema (46%), and para-articular enthesophytes (38%). The most commonly involved anatomical region was the hindfoot (73%). Conclusion: Our data showed that the incidence of foot involvement was very high in asymptomatic patients with psoriasis on MR imaging. Further MR studies are needed to confirm these data. We conclude that MR imaging may be of importance especially in early diagnosis and treatment of inflammatory changes in the foot

  1. Epidemiological and clinical analysis of a consecutive series of conjoined twins in Spain.

    Science.gov (United States)

    Martínez-Frías, María Luisa; Bermejo, Eva; Mendioroz, Jacobo; Rodríguez-Pinilla, Elvira; Blanco, Manuel; Egüés, Javier; Félix, Valentín; García, Angel; Huertas, Héctor; Nieto, Carmen; López, José Antonio; López, Santiago; Paisán, Luis; Rosa, Alejandro; Vázquez, María Socorro

    2009-04-01

    The aim of the study was to analyze the frequency and certain epidemiological characteristics of a consecutive series of conjoined twins born in Spain. We used data from the Spanish Collaborative Study of Congenital Malformations for the period April 1976 to 2006. Because the Spanish law permitting voluntary termination of pregnancies (TOP) when the fetus presented malformations was effective by the end of 1985, we analyzed the data in 4 periods, 2 before 1986 and 2 after. During the first period (1976-1979) only live births were recorded, whereas both still and live births were included in the other three (1980-1985, 1986-1995, and 1996-2006). In the present study, the cases were classified as symmetrical (16 pairs) and asymmetrical (1 pair) conjoined twins. Each pair of conjoined twins was considered as only one case for calculations, regardless of the type of union. Among a total of 2,281,604 consecutive births between 1980 and 2006, there were a total of 15 cases of symmetrical conjoined twins giving a frequency of 0.70 per 100,000 (1/152,107), whereas there was only 1 stillborn asymmetrical conjoined twin pair (0.04/100,000). Among the 13,418 consecutive stillborns surveyed, 6 cases of conjoined twins were identified (either symmetrical or asymmetrical) giving a frequency of 44.72 per 100,000, and 11 pairs were identified among the 2,425,583 total live births surveyed during the first period 1976 to 1979, a frequency of 0.45 per 100,000. Thus, the frequency among stillborn infants is 99.34 times higher than that observed among live births. However, the frequency for the total births (3 last periods) showed a decreasing trend from 1.47 per 100,000 birth in the first period (1980-1985) when TOP was illegal, to a value of 0.09 per 100,000 in the last period, more than 16-fold lower, probably because of the TOP of affected fetuses. Therefore, we consider that the frequencies observed in the period 1980 to 1985 are the basal values in our population. The most

  2. Paediatric 99mTc-DMSA imaging: reducing distress and rate of sedation using a psychological approach

    International Nuclear Information System (INIS)

    Train, H.; Colville, G.; Allan, R.; Thurlbeck, S.

    2006-01-01

    Aim: To evaluate the effect of a psychological approach on distress and sedation rates in children undergoing dimer captosuccinic acid-labelled with technetium-99 (99mTc) DMSA imaging. Materials and methods: Baseline data, on a retrospective consecutive sample of children examined using DMSA over a 6-month period (n = 81), were collected via medical note search and postal questionnaire. A further consecutive sample of 40 children was recruited prospectively to the intervention, which consisted of distraction during medical procedures and environmental manipulation. In addition half of the intervention group were provided with a photo-booklet depicting a coping child model, together with a letter offering advice to parents on how to prepare their child for the procedure. Results: Sedation rates were lower (p = 0.003) and service satisfaction ratings higher (p = 0.002) in the Intervention group as compared with the Baseline group. Within the intervention condition, children who received the photo-booklet displayed less distress before the procedure (p = 0.01) than those who did not. Also families who received the photo-booklet were more likely to attend the appointment (p = 0.024). Conclusion: In this study, the use of a psychological approach was associated with lower rates of distress and sedation in children undergoing 99mTc-DMSA imaging, without compromising image quality

  3. The impact of anal sphincter injury on perceived body image.

    Science.gov (United States)

    Iles, David; Khan, Rabia; Naidoo, Kristina; Kearney, Rohna; Myers, Jenny; Reid, Fiona

    2017-05-01

    Obstetric anal sphincter injury is common but the effect on body image is unreported. The aim of this study was to explore patient perceived changes in body image and other psychological aspects in women attending a perineal follow-up clinic. This retrospective study analysed women's responses to a self-reported questionnaire. Consecutive women with anal sphincter injury who attended a United Kingdom Maternity Hospital perineal follow-up clinic between January 1999 and January 2012 were identified and the records obtained and reviewed. Multivariate regression analyses were performed to examine variables influencing self-reported change in body image. Questionnaires and operation notes were analysed from 422 women who attended at a median of four months after delivery. 222 (53%) reported a change in body image with 80 (19%) reporting lower self-esteem and 75 (18%) a change in their personality due to the change in body image. 248 (59%) perceived an anatomical change due to the delivery. Factors associated with increased likelihood of reporting a change in body image were reporting a perceived change in anatomy due to the delivery, adjusted OR 6.11 (3.56-10.49), anal incontinence, OR 1.97 (1.16-3.36), and delivery by forceps, OR 2.59 (1.23-5.43). This is the first study to quantify body image changes in women after anal sphincter injury sustained in childbirth. These were found to be very common, affecting up to 50% of women. The study has several limitations but it does highlight the significant psychosocial problems of negative self-esteem and personality changes associated with a perceived change in body image that has not previously been reported. It also outlines the further research questions that need to be addressed. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. The Relationship Between Shoulder Stiffness and Rotator Cuff Healing: A Study of 1,533 Consecutive Arthroscopic Rotator Cuff Repairs.

    Science.gov (United States)

    McNamara, William J; Lam, Patrick H; Murrell, George A C

    2016-11-16

    Retear and stiffness are not uncommon outcomes of rotator cuff repair. The purpose of this study was to evaluate the relationship between rotator cuff repair healing and shoulder stiffness. A total of 1,533 consecutive shoulders had an arthroscopic rotator cuff repair by a single surgeon. Patients assessed their shoulder stiffness using a Likert scale preoperatively and at 1, 6, 12, and 24 weeks (6 months) postoperatively, and examiners evaluated passive range of motion preoperatively and at 6, 12, and 24 weeks postoperatively. Repair integrity was determined by ultrasound evaluation at 6 months. After rotator cuff repair, there was an overall significant loss of patient-ranked and examiner-assessed shoulder motion at 6 weeks compared with preoperative measurements (p rotator cuff integrity at 6 months postoperatively (r = 0.11 to 0.18; p rotation at 6 weeks postoperatively was 7%, while the retear rate of patients with >20° of external rotation at 6 weeks was 15% (p rotator cuff repair was more likely to heal. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  5. The way to safe and secure carotid endarterectomy. Review of 232 consecutive cases

    International Nuclear Information System (INIS)

    Moteki, Katsuhiko; Murayama, Takaya

    2007-01-01

    We investigated retrospectively perioperative and long-term complications of carotid endarterectomy (CEA) in 232 consecutive cases. Perioperative complications in surgical patients are 2.2% with no mortality. There was no perioperative embolic stroke in the later series of 130 CEA, although postoperative hyperperfusion was associated in two patients with edema and bleeding in their watershed area. We encountered 16 cases of pseudoocclusion, 11 cases were collapsed carotid arteries treated successfully by thromboendarterectomy, and 5 thrombosed cases were treated by CEA and thrombectomy, resulting in poor outcome. Thirteen cases of CEA with contlateral occlusion were performed uneventfully under intraluminal shunting. Redo operation for recurrent stenosis were performed successfully in 1.3% with patching. In the long-term follow-up of 118 consecutive cases, CEA had a clear benefit of preventing ipsilateral stroke in the first 3 years, but actual risks in long-term surgical patients were influenced more by their cardiac events than the stroke. Our findings suggest that managing cardiac events significantly affects life expectancy. (author)

  6. Intraspinal anomalies in scoliosis: An MRI analysis of 177 consecutive scoliosis patients

    Directory of Open Access Journals (Sweden)

    Rajasekaran S

    2010-01-01

    Full Text Available Background : The association of intraspinal neural anomalies with scoliosis is known for more than six decades. However, there are no studies documenting the incidence of association of intraspinal anomalies in scoliotic patients in the Indian population. The guide lines to obtain an magnetic resonance imaging (MRI scan to rule out neuro-axial abnormalities in presumed adolescent idiopathic scoliosis are also not clear. We conducted a prospective study (a to document and analyze the incidence and types of intraspinal anomalies in different types of scoliosis in Indian patients. (b to identify clinico-radiological ′indicators′ that best predict the findings of neuro-axial abnormalities in patients with presumed adolescent idiopathic scoliosis, which will alert the physician to the possible presence of intraspinal anomalies and optimize the use of MRI in this sub group of patients. Materials and Methods : The data from 177 consecutive scoliotic patients aged less than 21 years were analyzed. Patients were categorized into three groups; Group A - congenital scoliosis (n=60, group B -presumed idiopathic scoliosis (n=94 and group C - scoliosis secondary to neurofibromatosis, neuromuscular and connective tissue disorders (n=23. The presence and type of anomaly in the MRI was correlated to patient symptoms, clinical signs and curve characteristics. Results : The incidence of intraspinal anomalies in congenital scoliosis was 35% (21/60, with tethered cord due to filum terminale being the commonest anomaly (10/21. Patients with multiple vertebral anomalies had the highest incidence (48% of neural anomalies and isolated hemi vertebrae had none. In presumed ′idiopathic′ scoliosis patients the incidence was higher (16% than previously reported. Arnold Chiari-I malformation (AC-I with syringomyelia was the most common neural anomaly (9/15 and the incidence was higher in the presence of neurological findings (100%, apical kyphosis (66.6% and early

  7. Spectral-domain optical coherence tomography findings of the macula in 500 consecutive patients with uveitis.

    Science.gov (United States)

    Grajewski, R S; Boelke, A C; Adler, W; Meyer, S; Caramoy, A; Kirchhof, B; Cursiefen, C; Heindl, L M

    2016-11-01

    PurposeTo analyze the macular structure in a large series of consecutive patients with different types of uveitis using spectral-domain optical coherence tomography (SD-OCT).Patients and methodsFive hundred eyes of 500 consecutive patients with anterior, intermediate, posterior, and panuveitis underwent standardized macular examination using SD-OCT. Central retinal thickness (CRT), macular volume (MV), and presence of cystoid macular edema (CME), diffuse macular edema (DME), serous retinal detachment (SRD), epiretinal membrane with (ERM+) and without (ERM-) retinal surface wrinkling were determined.ResultsThe anatomic location of inflammation affected significantly CRT and MV (Pmacula is recommended for all uveitis patients. CRT, MV, and the incidence of CME were highest in intermediate and panuveitis.

  8. Intracranial solitary fibrous tumor: Imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Clarencon, Frederic, E-mail: fredclare5@msn.com [Department of Neuroradiology, Pitie-Salpetriere Hospital, APHP, 75013 Paris (France); Bonneville, Fabrice [Department of Neuroradiology, Hopital Rangueil, Toulouse University Hospital, 31000 Toulouse (France); Rousseau, Audrey [Department of Neuropathology, Pitie-Salpetriere Hospital (France); Galanaud, Damien [Department of Neuroradiology, Pitie-Salpetriere Hospital, APHP, 75013 Paris (France); Kujas, Michele [Department of Neuropathology, Pitie-Salpetriere Hospital (France); Naggara, Olivier [Department of Neuroradiology, St Anne Hospital, 75014 Paris (France); Cornu, Philippe [Department of Neurosurgery, Pitie-Salpetriere Hospital (France); Chiras, Jacques [Department of Neuroradiology, Pitie-Salpetriere Hospital, APHP, 75013 Paris (France)

    2011-11-15

    Objective: To study the neuroimaging features of intracranial solitary fibrous tumors (ISFTs). Materials and methods: Retrospective study of neuroimaging features of 9 consecutive histopathologically proven ISFT cases. Location, size, shape, density, signal intensity and gadolinium uptake were studied at CT and MRI. Data collected from diffusion-weighted imaging (DWI) (3 patients), perfusion imaging and MR spectroscopy (2 patients), and DSA (4 patients) were also analyzed. Results: The tumors most frequently arose from the intracranial meninges (7/9), while the other lesions were intraventricular. Tumor size ranged from 2.5 to 10 cm (mean = 6.6 cm). They presented multilobular shape in 6/9 patients. Most ISFTs were heterogeneous (7/9) with areas of low T2 signal intensity that strongly enhanced after gadolinium administration (6/8). Erosion of the skull was present in about half of the cases (4/9). Components with decreased apparent diffusion coefficient were seen in 2/3 ISFTs on DWI. Spectroscopy revealed elevated peaks of choline and myo-inositol. MR perfusion showed features of hyperperfusion. Conclusion: ISFT should be considered in cases of extra-axial, supratentorial, heterogeneous, hypervascular tumor. Areas of low T2 signal intensity that strongly enhance after gadolinium injection are suggestive of this diagnosis. Restricted diffusion and elevated peak of myo-inositol may be additional valuable features.

  9. Predictive variables for postoperative pain after 520 consecutive dental extraction surgeries.

    Science.gov (United States)

    Bortoluzzi, Marcelo Carlos; Manfro, Aline Rosler Grings; Nodari, Rudy Jose; Presta, Andreia Antoniuk

    2012-01-01

    The aim of this study was to evaluate postoperative pain in patients who had a single tooth or multiple erupted teeth extracted. This research evaluated 520 consecutive dental extraction surgeries in which 680 teeth were removed. Data collection was obtained through a questionnaire of patients and of the undergraduate students who performed all procedures. Pain was evaluated through qualitative self-reported scores at seven days postsurgery. An increased pain level was statistically associated with ostectomy, postoperative complications, and tobacco consumption. Pain that persisted for more than two days was statistically associated with the amount of anesthetic solution used, with a notable increase in surgical time and development of postoperative complications. Periods of pain lasting more than two days could be expected for traumatic surgeries lasting more than 30 minutes. Both severe and prolonged pain were signs of development of postoperative complications, such as alveolar osteitis and alveolar infection.

  10. Appearance of the canine meninges in subtraction magnetic resonance images.

    Science.gov (United States)

    Lamb, Christopher R; Lam, Richard; Keenihan, Erin K; Frean, Stephen

    2014-01-01

    The canine meninges are not visible as discrete structures in noncontrast magnetic resonance (MR) images, and are incompletely visualized in T1-weighted, postgadolinium images, reportedly appearing as short, thin curvilinear segments with minimal enhancement. Subtraction imaging facilitates detection of enhancement of tissues, hence may increase the conspicuity of meninges. The aim of the present study was to describe qualitatively the appearance of canine meninges in subtraction MR images obtained using a dynamic technique. Images were reviewed of 10 consecutive dogs that had dynamic pre- and postgadolinium T1W imaging of the brain that was interpreted as normal, and had normal cerebrospinal fluid. Image-anatomic correlation was facilitated by dissection and histologic examination of two canine cadavers. Meningeal enhancement was relatively inconspicuous in postgadolinium T1-weighted images, but was clearly visible in subtraction images of all dogs. Enhancement was visible as faint, small-rounded foci compatible with vessels seen end on within the sulci, a series of larger rounded foci compatible with vessels of variable caliber on the dorsal aspect of the cerebral cortex, and a continuous thin zone of moderate enhancement around the brain. Superimposition of color-encoded subtraction images on pregadolinium T1- and T2-weighted images facilitated localization of the origin of enhancement, which appeared to be predominantly dural, with relatively few leptomeningeal structures visible. Dynamic subtraction MR imaging should be considered for inclusion in clinical brain MR protocols because of the possibility that its use may increase sensitivity for lesions affecting the meninges. © 2014 American College of Veterinary Radiology.

  11. Imaging Differences between Neuromyelitis Optica Spectrum Disorders and Multiple Sclerosis: A Multi-Institutional Study in Japan.

    Science.gov (United States)

    Tatekawa, H; Sakamoto, S; Hori, M; Kaichi, Y; Kunimatsu, A; Akazawa, K; Miyasaka, T; Oba, H; Okubo, T; Hasuo, K; Yamada, K; Taoka, T; Doishita, S; Shimono, T; Miki, Y

    2018-05-03

    Both clinical and imaging criteria must be met to diagnose neuromyelitis optica spectrum disorders and multiple sclerosis. However, neuromyelitis optica spectrum disorders are often misdiagnosed as MS because of an overlap in MR imaging features. The purpose of this study was to confirm imaging differences between neuromyelitis optica spectrum disorders and MS with visually detailed quantitative analyses of large-sample data. We retrospectively examined 89 consecutive patients with neuromyelitis optica spectrum disorders (median age, 51 years; range, 16-85 years; females, 77; aquaporin 4 immunoglobulin G-positive, 93%) and 89 with MS (median age, 36 years; range, 18-67 years; females, 68; relapsing-remitting MS, 89%; primary-progressive MS, 7%; secondary-progressive MS, 2%) from 9 institutions across Japan (April 2008 to December 2012). Two neuroradiologists visually evaluated the number, location, and size of all lesions using the Mann-Whitney U test or the Fisher exact test. We enrolled 79 patients with neuromyelitis optica spectrum disorders and 87 with MS for brain analysis, 57 with neuromyelitis optica spectrum disorders and 55 with MS for spinal cord analysis, and 42 with neuromyelitis optica spectrum disorders and 14 with MS for optic nerve analysis. We identified 911 brain lesions in neuromyelitis optica spectrum disorders, 1659 brain lesions in MS, 86 spinal cord lesions in neuromyelitis optica spectrum disorders, and 102 spinal cord lesions in MS. The frequencies of periventricular white matter and deep white matter lesions were 17% and 68% in neuromyelitis optica spectrum disorders versus 41% and 42% in MS, respectively (location of brain lesions, P optica spectrum disorders (cervical versus thoracic, 29% versus 71%), whereas they were equally distributed in MS (46% versus 54%). Furthermore, thoracic lesions were significantly longer than cervical lesions in neuromyelitis optica spectrum disorders ( P = .001), but not in MS ( P = .80). Visually detailed

  12. Study on Processing Method of Image Shadow

    Directory of Open Access Journals (Sweden)

    Wang Bo

    2014-07-01

    Full Text Available In order to effectively remove disturbance of shadow and enhance robustness of information processing of computer visual image, this paper makes study on inspection and removal of image shadow. It makes study the continual removal algorithm of shadow based on integration, the illumination surface and texture, it respectively introduces their work principles and realization method, it can effectively carrying processing for shadow by test.

  13. Carpological variability of almond (Prunus dulcis [Mill.] D.A. Webb cv Nonpareil) in a single orchard during seven consecutive harvests

    Science.gov (United States)

    A multi-year study was conducted in California’s San Joaquin Valley to examine variability of carpological characteristics of the popular ‘Nonpareil’ almond cultivar. Samples of ‘Nonpareil’ almond fruit were collected from a single orchard during seven consecutive harvests and evaluated for 19 spec...

  14. The removal of the deep lateral wall in orbital decompression: Its contribution to exophthalmos reduction and influence on consecutive diplopia

    NARCIS (Netherlands)

    Baldeschi, Lelio; Macandie, Kerr; Hintschich, Christoph; Wakelkamp, Iris M. M. J.; Prummel, Mark F.; Wiersinga, Wilmar M.

    2005-01-01

    PURPOSE: To evaluate the contribution of maximal removal of the deep lateral wall of the orbit to exophthalmos reduction in Graves' orbitopathy and its influence on the onset of consecutive diplopia. DESIGN: Case-control study. METHODS: The medical records of two cohorts of patients affected by

  15. Time Spent by Breast Imaging Radiologists to Perform Value-Added Activities at an Academic Cancer Center.

    Science.gov (United States)

    Collado-Mesa, Fernando; Klevos, Geetika; Arheart, Kristopher; Banks, James; Yepes, Monica; Net, Jose

    2017-04-01

    Health care reform in the United States has generated a paradigm shift in the practice of radiology aimed at increasing the degree of patient-centered care. We conducted a study to quantify the amount of time breast imaging radiologists spend on value-added activities at an academic comprehensive cancer center located in Miami, Florida, and accredited by the American College of Radiology as a Breast Imaging Center of Excellence. A prospective, observational study was conducted during a period of 20 consecutive workdays. Three participating breast imaging radiologists maintained a real-time log of each activity performed. A generalized linear model was used to perform a 1-way analysis of variance. An alpha level of .05 was used to determine statistical significance. The average daily time dedicated to these activities was 92.1 minutes (range, 56.4-132.2). The amount of time significantly differed among breast imaging radiologists and correlated with their assigned daily role (P value-added activities to help improve patients' experience across the continuity of their care. We propose that similar studies be conducted at other institutions to better assess the magnitude of this finding across different breast imaging care settings.

  16. Single-Centre Experience with Percutaneous Cryoablation of Breast Cancer in 23 Consecutive Non-surgical Patients

    International Nuclear Information System (INIS)

    Cazzato, Roberto Luigi; Lara, Christine Tunon de; Buy, Xavier; Ferron, Stéphane; Hurtevent, Gabrielle; Fournier, Marion; Debled, Marc; Palussière, Jean

    2015-01-01

    AimTo present our single-centre prospective experience on the use of cryoablation (CA) applied to treat primary breast cancer (BC) in a cohort of patients unsuitable for surgical treatment.Materials and MethodsTwenty-three consecutive post-menopausal female patients (median age 85 years; range 56–96) underwent percutaneous CA of unifocal, biopsy-proven BC, under ultrasound/computed tomography (US/CT) guidance. Clinical and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) follow-ups were systematically scheduled at 3, 12, 18 and 24 months. Local tumour control was assessed by comparing baseline and follow-up DCE-MRI.ResultsTwenty-three BC (median size 14 mm) were treated under local anaesthesia (78.3 %) or local anaesthesia and conscious sedation (21.7 %). Median number of cryo-probes applied per session was 2.0. A “dual-freezing” protocol was applied for the first ten patients and a more aggressive “triple-freezing” protocol for the remaining 13. Median follow-up was 14.6 months. Five patients recurred during follow-up and two were successfully re-treated with CA. Five patients presented immediate CA-related complications: four hematomas evolved uneventfully at 3-month follow-up and one skin burn resulted in skin inflammation and skin retraction at 3 and 12 months, respectively.ConclusionsPercutaneous CA is safe and well tolerated for non-resected elderly BC patients. Procedures can be proposed under local anaesthesia only. Given the insulation properties of the breast gland, aggressive CA protocols are required. Prospective studies are needed to better understand the potential role of CA in the local treatment of early BC

  17. Single-Centre Experience with Percutaneous Cryoablation of Breast Cancer in 23 Consecutive Non-surgical Patients

    Energy Technology Data Exchange (ETDEWEB)

    Cazzato, Roberto Luigi, E-mail: r.cazzato@unicampus.it [Institut Bergonié, Comprehensive Cancer Centre, Department of Medical Imaging (France); Lara, Christine Tunon de, E-mail: c.tunondelara@bordeaux.unicancer.fr [Institut Bergonié, Comprehensive Cancer Centre, Department of Surgery (France); Buy, Xavier, E-mail: x.buy@bordeaux.unicancer.fr; Ferron, Stéphane, E-mail: s.ferron@bordeaux.unicancer.fr; Hurtevent, Gabrielle, E-mail: g.hurtevent@bordeaux.unicancer.fr [Institut Bergonié, Comprehensive Cancer Centre, Department of Medical Imaging (France); Fournier, Marion, E-mail: m.fournier@bordeaux.unicancer.fr [Institut Bergonié, Comprehensive Cancer Centre, Department of Surgery (France); Debled, Marc, E-mail: m.debled@bordeaux.unicancer.fr [Institut Bergonié, Comprehensive Cancer Centre, Department of Medical Oncology (France); Palussière, Jean, E-mail: j.palussiere@bordeaux.unicancer.fr [Institut Bergonié, Comprehensive Cancer Centre, Department of Medical Imaging (France)

    2015-10-15

    AimTo present our single-centre prospective experience on the use of cryoablation (CA) applied to treat primary breast cancer (BC) in a cohort of patients unsuitable for surgical treatment.Materials and MethodsTwenty-three consecutive post-menopausal female patients (median age 85 years; range 56–96) underwent percutaneous CA of unifocal, biopsy-proven BC, under ultrasound/computed tomography (US/CT) guidance. Clinical and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) follow-ups were systematically scheduled at 3, 12, 18 and 24 months. Local tumour control was assessed by comparing baseline and follow-up DCE-MRI.ResultsTwenty-three BC (median size 14 mm) were treated under local anaesthesia (78.3 %) or local anaesthesia and conscious sedation (21.7 %). Median number of cryo-probes applied per session was 2.0. A “dual-freezing” protocol was applied for the first ten patients and a more aggressive “triple-freezing” protocol for the remaining 13. Median follow-up was 14.6 months. Five patients recurred during follow-up and two were successfully re-treated with CA. Five patients presented immediate CA-related complications: four hematomas evolved uneventfully at 3-month follow-up and one skin burn resulted in skin inflammation and skin retraction at 3 and 12 months, respectively.ConclusionsPercutaneous CA is safe and well tolerated for non-resected elderly BC patients. Procedures can be proposed under local anaesthesia only. Given the insulation properties of the breast gland, aggressive CA protocols are required. Prospective studies are needed to better understand the potential role of CA in the local treatment of early BC.

  18. Contamination of Ambient Air with Acinetobacter baumannii on Consecutive Inpatient Days.

    Science.gov (United States)

    Shimose, Luis A; Doi, Yohei; Bonomo, Robert A; De Pascale, Dennise; Viau, Roberto A; Cleary, Timothy; Namias, Nicholas; Kett, Daniel H; Munoz-Price, L Silvia

    2015-07-01

    Acinetobacter-positive patients had their ambient air tested for up to 10 consecutive days. The air was Acinetobacter positive for an average of 21% of the days; the rate of contamination was higher among patients colonized in the rectum than in the airways (relative risk [RR], 2.35; P = 0.006). Of the 6 air/clinical isolate pairs available, 4 pairs were closely related according to rep-PCR results. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  19. Incidence and Imaging Findings of Costal Cartilage Fractures in Patients with Blunt Chest Trauma: A Retrospective Review of 1461 Consecutive Whole-Body CT Examinations for Trauma.

    Science.gov (United States)

    Nummela, Mari T; Bensch, Frank V; Pyhältö, Tuomo T; Koskinen, Seppo K

    2018-02-01

    Purpose To assess the incidence of costal cartilage (CC) fractures in whole-body computed tomographic (CT) examinations for blunt trauma and to evaluate distribution of CC fractures, concomitant injuries, mechanism of injury, accuracy of reporting, and the effect on 30-day mortality. Materials and Methods Institutional review board approval was obtained for this retrospective study. All whole-body CT examinations for blunt trauma over 36 months were reviewed retrospectively and chest trauma CT studies were evaluated by a second reader. Of 1461 patients who underwent a whole-body CT examination, 39% (574 of 1461) had signs of thoracic injuries (men, 74.0% [425 of 574]; mean age, 46.6 years; women, 26.0% [149 of 574]; mean age, 48.9 years). χ 2 and odds ratios (ORs) with 95% confidence intervals (CIs) were calculated. Interobserver agreement was calculated by using Cohen kappa values. Results A total of 114 patients (men, 86.8% [99 of 114]; mean age, 48.6 years; women, 13.2% [15 of 114]; mean age, 45.1 years) had 221 CC fractures. The incidence was 7.8% (114 of 1461) in all whole-body CT examinations and 19.9% (114 of 574) in patients with thoracic trauma. Cartilage of rib 7 (21.3%, 47 of 221) was most commonly injured. Bilateral multiple consecutive rib fractures occurred in 36% (41 of 114) versus 14% (64 of 460) in other patients with chest trauma (OR, 3.48; 95% CI: 2.18, 5.53; P chest trauma with CC fractures (13%, 15 of 114) versus patients with chest trauma without CC fractures (4%, 18 of 460) (OR, 3.72; 95% CI: 1.81, 7.64; P = .0001), as well as aortic injuries (n = 4 vs n = 0; P = .0015; OR, unavailable). Kappa value for interobserver agreement in detecting CC fractures was 0.65 (substantial agreement). CC fractures were documented in 39.5% (45 of 114) of primary reports. The 30-day mortality of patients with CC fractures was 7.02% (eight of 114) versus 4.78% (22 of 460) of other patients with chest trauma (OR, 1.50; 95% CI: 0.65, 3.47; P = .3371). Conclusion

  20. Adverse reaction to metal debris in a consecutive series of DUROM™ hip resurfacing: pseudotumour incidence and metal ion concentration.

    Science.gov (United States)

    Hartmann, Albrecht; Kieback, Jan-Dirk; Lützner, Jörg; Günther, Klaus-Peter; Goronzy, Jens

    2017-07-25

    The aim of this study was to evaluate the incidence of adverse reactions to metal debris (ARMD) in a consecutive series of DUROM™ Hip Resurfacing Arthroplasty (HRA) at mid-term follow-up. Between October 2003 and March 2007 a total of 134 consecutive DUROM™ HRA in 121 patients were performed at our institution. Follow-up could be obtained in 101 unrevised patients (83%) at a mean time of 8.51 ± 0.97 years postoperatively and included patient-related outcome measurement, plain radiographs, MARS-MRI as well as whole blood metal ion assessment. 17 (16.5%) out of 103 hips revealed pseudotumour occurrence in MRI investigation, 1 (10.6%) with a diameter of ≥2 cm. Higher incidence of pseudotumours was found patients with femoral component size 7 μg/l. In contrast to cobalt determination, only elevated chromium values showed a positive association with pseudotumour occurrence and size. A significant proportion of patients developed pseudotumours and metal ion elevation in a consecutive cohort of DUROM™ HRA after mid-term follow-up. The incidence, however, seems not to differ from results of other well performing resurfacing brands; clinical relevance of our findings is unclear. Regarding potential local as well as systemic effects of metal particle release, close follow-up of patients is essential, even with clinically well-performing implants.

  1. Optimization of an Image-Based Talking Head System

    Directory of Open Access Journals (Sweden)

    Kang Liu

    2009-01-01

    Full Text Available This paper presents an image-based talking head system, which includes two parts: analysis and synthesis. The audiovisual analysis part creates a face model of a recorded human subject, which is composed of a personalized 3D mask as well as a large database of mouth images and their related information. The synthesis part generates natural looking facial animations from phonetic transcripts of text. A critical issue of the synthesis is the unit selection which selects and concatenates these appropriate mouth images from the database such that they match the spoken words of the talking head. Selection is based on lip synchronization and the similarity of consecutive images. The unit selection is refined in this paper, and Pareto optimization is used to train the unit selection. Experimental results of subjective tests show that most people cannot distinguish our facial animations from real videos.

  2. Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse.

    Science.gov (United States)

    Long, K J; Bonagura, J D; Darke, P G

    1992-05-01

    Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subsequently examined using this standardised technique. Selected cardiac dimensions were measured from two-dimensional and guided M-mode studies. Satisfactory results were achieved in 26 of the 27 horses. There was no linear correlation between any of the measured cardiac values and bodyweight. There was no significant difference between measurements taken from the left and the right hemithorax. Six horses were imaged on three consecutive days to assess the repeatability of the measurements. No significant difference was found between measurements obtained on different days. This study demonstrates a method for standardised echocardiographic evaluation of the equine heart that is repeatable, valuable for teaching techniques of equine echocardiography, applicable for diagnostic imaging and quantification of cardiac size, and useful for the evaluation of blood-flow patterns by Doppler ultrasound.

  3. Automatic registration of multi-modal microscopy images for integrative analysis of prostate tissue sections

    International Nuclear Information System (INIS)

    Lippolis, Giuseppe; Edsjö, Anders; Helczynski, Leszek; Bjartell, Anders; Overgaard, Niels Chr

    2013-01-01

    Prostate cancer is one of the leading causes of cancer related deaths. For diagnosis, predicting the outcome of the disease, and for assessing potential new biomarkers, pathologists and researchers routinely analyze histological samples. Morphological and molecular information may be integrated by aligning microscopic histological images in a multiplex fashion. This process is usually time-consuming and results in intra- and inter-user variability. The aim of this study is to investigate the feasibility of using modern image analysis methods for automated alignment of microscopic images from differently stained adjacent paraffin sections from prostatic tissue specimens. Tissue samples, obtained from biopsy or radical prostatectomy, were sectioned and stained with either hematoxylin & eosin (H&E), immunohistochemistry for p63 and AMACR or Time Resolved Fluorescence (TRF) for androgen receptor (AR). Image pairs were aligned allowing for translation, rotation and scaling. The registration was performed automatically by first detecting landmarks in both images, using the scale invariant image transform (SIFT), followed by the well-known RANSAC protocol for finding point correspondences and finally aligned by Procrustes fit. The Registration results were evaluated using both visual and quantitative criteria as defined in the text. Three experiments were carried out. First, images of consecutive tissue sections stained with H&E and p63/AMACR were successfully aligned in 85 of 88 cases (96.6%). The failures occurred in 3 out of 13 cores with highly aggressive cancer (Gleason score ≥ 8). Second, TRF and H&E image pairs were aligned correctly in 103 out of 106 cases (97%). The third experiment considered the alignment of image pairs with the same staining (H&E) coming from a stack of 4 sections. The success rate for alignment dropped from 93.8% in adjacent sections to 22% for sections furthest away. The proposed method is both reliable and fast and therefore well suited

  4. Image processing of angiograms: A pilot study

    Science.gov (United States)

    Larsen, L. E.; Evans, R. A.; Roehm, J. O., Jr.

    1974-01-01

    The technology transfer application this report describes is the result of a pilot study of image-processing methods applied to the image enhancement, coding, and analysis of arteriograms. Angiography is a subspecialty of radiology that employs the introduction of media with high X-ray absorption into arteries in order to study vessel pathology as well as to infer disease of the organs supplied by the vessel in question.

  5. FAIR imaging of the liver. A preliminary study

    International Nuclear Information System (INIS)

    Kiryu, Shigeru; Machida, Toru; Noda, Masanobu

    1998-01-01

    Flow-sensitive alternating inversion recovery (FAIR) technique has recently been introduced for perfusion or functional MR studies of the brain. In the imaging of liver neoplasms, the evaluation of tumor vascularity is important for diagnosis, and therefore the FAIR technique may potentially complement liver MR imaging. The purpose of this study was to evaluate the usefulness of a FAIR sequence in MR imaging of the liver and to compare it with arterial-phase images of dynamic MR imaging. One volunteer and six patients with focal hepatic lesions (one with hepatocellular carcinoma (HCC), three with metastasis, and two with cavernous hemangioma) underwent FAIR. Short TI (600 ms) and long TI (1200 ms) images were obtained during breath-hold. In normal volunteers, the vessels generated remarkably bright signal in both short and long TI. Signal intensity of liver parenchyma was low in short TI, and became stronger in long TI. Two HCC (in one patient) (100%), one hemangioma (50%), and three metastases (100%) were well delineated as bright lesions. One HCC produced peripheral high intensity in short-TI FAIR image, and this finding was consistent with the result of dynamic MR study. Another HCC, which showed no clear enhancement in the arterial-phase dynamic MRI, was visualized only in long-TI FAIR. One hemangioma, which was clearly seen in FAIR image, showed rapid and strong enhancement on dynamic MRI. It is concluded that FAIR is a promising technique for evaluation of vascularity of hepatic tumors without using contrast materials. (author)

  6. Reflex sympathetic dystrophy syndrome: MR imaging study

    International Nuclear Information System (INIS)

    Masciocchi, C.; Fascetti, E.; Bonanni, G.; Calvisi, V.; Buoni, C.; Passariello, R.

    1987-01-01

    Reflex sympathetic dystrophy syndrome (RSDS) is characterized by pain, swelling, and limitation of motion. The etiology and pathophysiology mechanism have not yet been identified. We considered eight patients with clinical signs of RSDS, in five cases located at the knee joint and in three cases in the hip. In all cases conventional radiography and radionuclide bone scanning were performed before MR imaging. Conventional radiography was negative in three cases while scintigraphy demonstrated the lesion in all patients. MR imaging showed an area of low intensity signal on T1-weighted scans and an increased signal intensity on T2-weighted images. This area is located at the bone marrow and its regular and homogeneous. This specific finding on MR images is due to reflect edema by hyperemia of the bone marrow. The MR imaging diagnosis was confirmed on clinical and radiological follow-up. MR imaging can have a role in the differential diagnosis when other studies are nondiagnostic or nonspecific for RSDS

  7. New patient-controlled abdominal compression method in radiography: radiation dose and image quality.

    Science.gov (United States)

    Piippo-Huotari, Oili; Norrman, Eva; Anderzén-Carlsson, Agneta; Geijer, Håkan

    2018-05-01

    The radiation dose for patients can be reduced with many methods and one way is to use abdominal compression. In this study, the radiation dose and image quality for a new patient-controlled compression device were compared with conventional compression and compression in the prone position . To compare radiation dose and image quality of patient-controlled compression compared with conventional and prone compression in general radiography. An experimental design with quantitative approach. After obtaining the approval of the ethics committee, a consecutive sample of 48 patients was examined with the standard clinical urography protocol. The radiation doses were measured as dose-area product and analyzed with a paired t-test. The image quality was evaluated by visual grading analysis. Four radiologists evaluated each image individually by scoring nine criteria modified from the European quality criteria for diagnostic radiographic images. There was no significant difference in radiation dose or image quality between conventional and patient-controlled compression. Prone position resulted in both higher dose and inferior image quality. Patient-controlled compression gave similar dose levels as conventional compression and lower than prone compression. Image quality was similar with both patient-controlled and conventional compression and was judged to be better than in the prone position.

  8. An Exploratory Study of Residents’ Perception of Place Image

    Science.gov (United States)

    Stylidis, Dimitrios; Sit, Jason; Biran, Avital

    2014-01-01

    Studies on place image have predominantly focused on the tourists’ destination image and have given limited attention to other stakeholders’ perspectives. This study aims to address this gap by focusing on the notion of residents’ place image, whereby it reviews existing literature on residents’ place image in terms of whether common attributes can be identified, and examines the role of community-focused attributes in its measurement. Data collected from a sample of 481 Kavala residents (Greece) were subjected to exploratory and confirmatory factor analysis. The study reveals that the existing measurement tools have typically emphasized destination-focused attributes and neglected community-focused attributes. This study contributes to the residents’ place image research by proposing a more holistic measurement, which consisted of four dimensions: physical appearance, community services, social environment, and entertainment opportunities. The study also offers practical insights for developing and promoting a tourist place while simultaneously enhancing its residents’ quality of life. PMID:29708109

  9. Radiation: Rational use of diagnostic imaging studies in pediatrics

    International Nuclear Information System (INIS)

    Gentile, Fernando

    2008-01-01

    The objectives of this paper are to recognize the biological effects of radiation; explain the action of ionizing radiation on the cell; list the main sources of ionizing radiation; to indicate imaging studies considering the danger of radiation; select the method of imaging saving radiation; rational use of imaging studies without repeating exams. [es

  10. Neovascularization in Vertebral Artery Atheroma-A Dynamic Contrast-Enhanced Magnetic Resonance Imaging-Based Comparative Study in Patients with Symptomatic and Asymptomatic Carotid Artery Disease.

    Science.gov (United States)

    Usman, Ammara; Yuan, Jianmin; Patterson, Andrew J; Graves, Martin J; Varty, Kevin; Sadat, Umar; Gillard, Jonathan H

    2018-05-24

    Atherosclerosis is a systemic inflammatory disease intertwined with neovascularization. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) enables the assessment of plaque neovascularization. This study aimed to explore the systemic nature of atherosclerosis by assessing difference in severity of neovascularization as quantified by DCE-MRI of vertebral arteries (VAs) between patients with symptomatic and asymptomatic carotid artery disease. Ten consecutive patients with asymptomatic VA stenosis and concomitant symptomatic carotid artery disease (group 1) and 10 consecutive patients with asymptomatic VA stenosis and concomitant asymptomatic carotid artery disease (group 2) underwent 3-dimensional DCE-MRI of their cervical segment of VAs. A previously validated pharmacokinetic modeling approach was used for DCE-MRI analysis. K trans was calculated in the adventitia and plaque as a measure of neovessel permeability. Both patient groups were comparable for demographics and comorbidities. Mean luminal stenosis was comparable for both groups (54.4% versus 52.27%, P = .32). Group 1 had higher adventitial K trans and plaque K trans (.08 ± .01 min -1 , .07 ± .01 min -1 ) compared with Group 2 (.06 ± .01 min -1 , .06 ± .01 min -1 ) (P = .004 and .03, respectively). Good correlation was present among the two image analysts (intraclass correlation coefficient = .78). Vertebral Artery atheroma of patients with symptomatic carotid artery disease had increased neovessel permeability compared with the patients with asymptomatic carotid artery disease. These findings are consistent with the hypothesis that atherosclerosis is a systemic inflammatory disease. The VA atherosclerosis is likely to have increased severity of neovascularization if another arterial territory is symptomatic in the same patient cohort. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  11. Clinical application of EPI diffusion weighted image (DWI) for ischemic brain disease

    International Nuclear Information System (INIS)

    Zenke, Kiichiro; Kusunoki, Katsusuke; Saito, Masahiro; Sadamoto, Kazuhiko; Sakaki, Saburo; Kumon, Yoshiaki; Nagasawa, Kiyoshi

    1999-01-01

    Diffusion-weighted magnetic resonance image (DWI) with Echo Planar imaging (EPI) techniques were utilized in 74 consecutive patients who were suspected or diagnosed as having occlusive cerebrovascular diseases. Of three EPI-DWI techniques-single shot DWI, multi-shot DWI and isotropic DWI-, isotropic DWI was the most useful study for diagnosing occlusive cerebro-vascular disease. EPI-DWI could identify fresh infarction, even small cortical infarctions, in the setting of multiple high intensity lesions shown by T2 weighted image (T2WI), and could detect infarcted lesions early after the onset. In the patients whose lesions were not revealed on the initial EPI-DWIs, new infarcted lesion were not found on later MRIs, and their symptoms disappeared completely. High intensity lesions observed on EPI-DWIs mostly decreased signal intensities about 2 weeks after the onset, and the intensities of lesions in the gray matter were reduced earlier than those in the white matter. (author)

  12. Detection of colorectal hepatic metastases using MnDPDP MR imaging and diffusion-weighted imaging (DWI) alone and in combination

    International Nuclear Information System (INIS)

    Koh, D.M.; Brown, G.; Riddell, A.M.; Scurr, E.; Allen, S.D.; Husband, J.E.; Collins, D.J.; Souza, N.M. de; Leach, M.O.; Chau, I.; Cunningham, D.

    2008-01-01

    To compare the diagnostic accuracy of MnDPDP MR imaging and diffusion-weighted imaging (DWI), alone and in combination, for detecting colorectal liver metastases in patients with suspected metastatic disease. Thirty-three consecutive patients with suspected colorectal liver metastases underwent MR imaging. Three image sets (MnDPDP, DWI and combined MnDPDP and DWI) were reviewed independently by two observers. Lesions were scored on a five-point scale for malignancy and the areas (Az) under the receiver operating characteristic curves were calculated for each observer and image set. The sensitivity and specificity for lesion detection were calculated for each image set and compared. There were 83 metastases, 49 cysts and 1 haemangioma. Using the combined set resulted in the highest diagnostic accuracy for both observers (Az = 0.94 and 0.96), with improved averaged sensitivity of lesion detection compared with the DWI set (p = 0.01), and a trend towards improved sensitivity compared with the MnDPDP set (p = 0.06). There was no difference in the averaged specificity using any of the three image sets (p > 0.5). Combination of MnDPDP MR imaging and DWI resulted in the highest diagnostic accuracy and can increase sensitivity without loss in specificity. (orig.)

  13. Thoracic lateral extracavitary corpectomy for anterior column reconstruction with expandable and static titanium cages: clinical outcomes and surgical considerations in a consecutive case series.

    Science.gov (United States)

    Holland, Christopher M; Bass, David I; Gary, Matthew F; Howard, Brian M; Refai, Daniel

    2015-02-01

    Many surgical interventions have emerged as effective means of restoring mechanical stability of the anterior column of the spine. The lateral extracavitary approach (LECA) allows for broad visualization and circumferential reconstruction of the spinal column. However, early reports demonstrated significant complication rates, protracted operative times, and prolonged hospitalizations. More recent reports have highlighted concerns for subsidence, particularly with expandable cages. Our work seeks to describe a single-surgeon consecutive series of patients undergoing LECA for thoracic corpectomy. Specifically, the objective was to explore the surgical considerations, clinical and radiographic outcomes, and complication profile of this approach. A retrospective study examined data from 17 consecutive patients in whom single or multi-level corpectomy was performed via a LECA by a single surgeon. Vertebral body replacement was achieved with either a static or expandable titanium cage. The Karnofsky Performance Scale (KPS) was utilized to assess patient functional status before and after surgery. Radiographic outcomes, particularly footplate-to-body ratio and subsidence, were assessed on CT imaging at 6 weeks after surgery and at follow-up of at least 6 months. The majority of patients had post-operative KPS scores consistent with functional independence (≥70, 12/17 patients, 71%). Fourteen patients had improved or maintained function by last follow-up. In both groups, all patients had a favorable footplate-to-body ratio, and rates of subsidence were similar at both time points. Notably, the overall complication rate (24%) was significantly lower than that published in the literature, and no patient suffered a pneumothorax that required placement of a thoracostomy tube. The LECA approach for anterior column reconstruction with static or expandable cages is an important surgical consideration with favorable surgical parameters and complication rates. Further, use of

  14. Simultaneous high-speed spectral and infrared imaging of engine combustion

    Science.gov (United States)

    Jansons, Marcis

    2005-11-01

    A novel and unique diagnostic apparatus has been developed and applied to combustion gas mixtures in engine cylinders. The computer-controlled system integrates a modified Fastie-Ebert type spectrophotometer with four infrared CCD imagers, allowing the simultaneous acquisition of the spectrum and four spatial images, each at a discrete wavelength. Data buffering allows continuous imaging of the power stroke over consecutive engine cycles at framing rates of 1850 frames/second. Spectral resolution is 28nm with an uncertainty better than 58nm. The nominal response of the instrument is in the range 1.8--4.5mum, with a peak responsivity near the important 2.7mum bands of CO2 and H2O. The spectral range per scan is approximately 1.78mum. To interpret the measured data, a line-by-line radiation model was created utilizing the High-Resolution Transmission (HITRAN) database of molecular parameters, incorporating soot and wall emission effects. Although computationally more intensive, this model represents an improvement in accuracy over the NASA single-line-group (SLG) model which does not include the 'hot' CO2 lines of the 3.8mum region. Methane/air combustion mixture thermodynamic parameters are estimated by the iteration of model variables to yield a synthetic spectrum that, when corrected for wall effects, instrument function, responsivity, window and laboratory path transmissivity, correspond to the measured spectrum. The values of the model variables are used to interpret the corresponding spatial images. For the first time in the infrared an entire engine starting sequence has been observed over consecutive cycles. Preflame spectra measured during the compression stroke of a spark-ignition engine operating with various fuels correlate well with the synthetic spectra of the particular hydrocarbon reactants. The ability to determine concentration and spatial distribution of fuel in the engine cylinder prior to ignition has applications in stratified charge studies and

  15. Neuropsychological, neurological and functional outcome following pallidotomy for Parkinson's disease. A consecutive series of eight simultaneous bilateral and twelve unilateral procedures.

    Science.gov (United States)

    Scott, R; Gregory, R; Hines, N; Carroll, C; Hyman, N; Papanasstasiou, V; Leather, C; Rowe, J; Silburn, P; Aziz, T

    1998-04-01

    Intellectual, psychological and functional outcomes were evaluated in a consecutive series of 20 Parkinsonian patients who had unilateral (UPVP) or simultaneous bilateral posteroventral pallidotomy (BPVP) using Image Fusion and Stereoplan (Radionics Inc., Boston, Mass., USA) with stimulation for lesion localization. Comprehensive baseline and 3-month postoperative neuropsychological and neurological assessment protocols were administered together with questionnaire measures of functional disability, quality of life and psychological symptomatology. Changes in patients' clinical presentation and scores on psychometric tests, questionnaires and observational rating scales were then examined. We observed no new neuropsychiatric sequelae directly related to pallidotomy. Cognitive sequelae were restricted to selective reductions in categorical verbal fluency following UPVP (P improvement on neurological rating scales; following UPVP, Total Unified Parkinson's Disease Rating Scale (UPDRS) scores improved by 27% (P improvement was 53% (P improvements in 'quality of life' also achieved statistical significance on a number of both physical and psychosocial questionnaire subscales.

  16. Brain perfusion SPECT imaging before and during the acetazolamide test using sup 99m Tc-HMPAO

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Hiroshi; Higashi, Sotaro; Kinuya, Keiko; Tsuji, Shiro; Sumiya, Hisashi; Hisada, Kinichi; Yamashita, Junkoh (Kanazawa Univ. (Japan). School of Medicine)

    1990-05-01

    A new method using brain perfusion {sup 99m}Tc-HMPAO SPECT imaging was developed for evaluating cerebral perfusion reserve by the acetazolamide test with a short period. The first SPECT study was carried out for 13.5 min to obtain SPECT images at the resting state after 3 min postinjection of 555 MBq (15 mCi) of {sup 99m}Tc-HMPAO. At the same time as the start of the first SPECT study, 1 g of acetazolamide was intravenously injected. Immediately after the stop of the 1st SPECT study, 925 MBq (25 mCi) of {sup 99m}Tc-HMPAO from the same vial as in the first study was additionally injected. Three minutes later the second SPECT study was carried out for 10 min. After reconstruction the tomographic images in the first study were subtracted from the images in the second study to obtain those during the acetazolamide test after correction of the time differences in data acquisition between the two studies. This subtraction technique gives independent brain perfusion SPECT images before and during the acetazolamide test. Besides, the regional flow changes during the test were quantitatively analyzed. In conclusion this method seems to be practically useful for evaluating regional brain perfusion before and during drug treatments as a consecutive study with a short period of approximately 30 min. (author).

  17. Study on interference between far-IR to mm-wave CSR from consecutive electron bunches at BFEL RF-Linac

    CERN Document Server

    Biao, Z J; Xie Jia Li; Zhang Guo Qing

    2001-01-01

    Coherent bending magnet or undulator radiation due to a train of electron bunches is treated as radiation from a multi-slit diffraction array. Based on this model, we numerically analyse the interference among coherent synchrotron radiation emitted from consecutive bunches in a train of bunches, which are accelerated by a 30-MeV RF-linac at BFEL. Some interesting results are as follows: (1) Rapidly oscillating radiation enhancement due to interbunch interference is overlapped on the single bunch spectrum. (2) It consists of a series of spectrum lines corresponding to harmonics of the RF fundamental. (3) Main maximum positions are determined by the 'diffraction condition'. (4) Total intensity is about the square of the number of bunches participating in interference as single bunch intensity. Experimental design to measure interbunch interference at BFEL with the sub-mm and mm-wave Michelson interferometer is presented.

  18. Adaptive Statistical Iterative Reconstruction-V Versus Adaptive Statistical Iterative Reconstruction: Impact on Dose Reduction and Image Quality in Body Computed Tomography.

    Science.gov (United States)

    Gatti, Marco; Marchisio, Filippo; Fronda, Marco; Rampado, Osvaldo; Faletti, Riccardo; Bergamasco, Laura; Ropolo, Roberto; Fonio, Paolo

    The aim of this study was to evaluate the impact on dose reduction and image quality of the new iterative reconstruction technique: adaptive statistical iterative reconstruction (ASIR-V). Fifty consecutive oncologic patients acted as case controls undergoing during their follow-up a computed tomography scan both with ASIR and ASIR-V. Each study was analyzed in a double-blinded fashion by 2 radiologists. Both quantitative and qualitative analyses of image quality were conducted. Computed tomography scanner radiation output was 38% (29%-45%) lower (P ASIR-V examinations than for the ASIR ones. The quantitative image noise was significantly lower (P ASIR-V. Adaptive statistical iterative reconstruction-V had a higher performance for the subjective image noise (P = 0.01 for 5 mm and P = 0.009 for 1.25 mm), the other parameters (image sharpness, diagnostic acceptability, and overall image quality) being similar (P > 0.05). Adaptive statistical iterative reconstruction-V is a new iterative reconstruction technique that has the potential to provide image quality equal to or greater than ASIR, with a dose reduction around 40%.

  19. Study of fish response using particle image velocimetry and high-speed, high-resolution imaging

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Richmond, M. C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mueller, R. P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gruensch, G. R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2004-10-01

    Fish swimming has fascinated both engineers and fish biologists for decades. Digital particle image velocimetry (DPIV) and high-speed, high-resolution digital imaging are recently developed analysis tools that can help engineers and biologists better understand how fish respond to turbulent environments. This report details studies to evaluate DPIV. The studies included a review of existing literature on DPIV, preliminary studies to test the feasibility of using DPIV conducted at our Flow Biology Laboratory in Richland, Washington September through December 2003, and applications of high-speed, high-resolution digital imaging with advanced motion analysis to investigations of fish injury mechanisms in turbulent shear flows and bead trajectories in laboratory physical models. Several conclusions were drawn based on these studies, which are summarized as recommendations for proposed research at the end of this report.

  20. Study on edge-extraction of remote sensing image

    International Nuclear Information System (INIS)

    Wen Jianguang; Xiao Qing; Xu Huiping

    2005-01-01

    Image edge-extraction is an important step in image processing and recognition, and also a hot spot in science study. In this paper, based on primary methods of the remote sensing image edge-extraction, authors, for the first time, have proposed several elements which should be considered before processing. Then, the qualities of several methods in remote sensing image edge-extraction are systematically summarized. At last, taking Near Nasca area (Peru) as an example the edge-extraction of Magmatic Range is analysed. (authors)

  1. SlideToolkit: an assistive toolset for the histological quantification of whole slide images.

    Directory of Open Access Journals (Sweden)

    Bastiaan G L Nelissen

    Full Text Available The demand for accurate and reproducible phenotyping of a disease trait increases with the rising number of biobanks and genome wide association studies. Detailed analysis of histology is a powerful way of phenotyping human tissues. Nonetheless, purely visual assessment of histological slides is time-consuming and liable to sampling variation and optical illusions and thereby observer variation, and external validation may be cumbersome. Therefore, within our own biobank, computerized quantification of digitized histological slides is often preferred as a more precise and reproducible, and sometimes more sensitive approach. Relatively few free toolkits are, however, available for fully digitized microscopic slides, usually known as whole slides images. In order to comply with this need, we developed the slideToolkit as a fast method to handle large quantities of low contrast whole slides images using advanced cell detecting algorithms. The slideToolkit has been developed for modern personal computers and high-performance clusters (HPCs and is available as an open-source project on github.com. We here illustrate the power of slideToolkit by a repeated measurement of 303 digital slides containing CD3 stained (DAB abdominal aortic aneurysm tissue from a tissue biobank. Our workflow consists of four consecutive steps. In the first step (acquisition, whole slide images are collected and converted to TIFF files. In the second step (preparation, files are organized. The third step (tiles, creates multiple manageable tiles to count. In the fourth step (analysis, tissue is analyzed and results are stored in a data set. Using this method, two consecutive measurements of 303 slides showed an intraclass correlation of 0.99. In conclusion, slideToolkit provides a free, powerful and versatile collection of tools for automated feature analysis of whole slide images to create reproducible and meaningful phenotypic data sets.

  2. Indo-Pacific sea surface temperature influences on failed consecutive rainy seasons over eastern Africa

    Science.gov (United States)

    Hoell, Andrew; Funk, Christopher C.

    2014-01-01

    Rainfall over eastern Africa (10°S–10°N; 35°E–50°E) is bimodal, with seasonal maxima during the "long rains" of March–April–May (MAM) and the "short rains" of October–November–December (OND). Below average precipitation during consecutive long and short rains seasons over eastern Africa can have devastating long-term impacts on water availability and agriculture. Here, we examine the forcing of drought during consecutive long and short rains seasons over eastern Africa by Indo-Pacific sea surface temperatures (SSTs). The forcing of eastern Africa precipitation and circulation by SSTs is tested using ten ensemble simulations of a global weather forecast model forced by 1950–2010 observed global SSTs. Since the 1980s, Indo-Pacific SSTs have forced more frequent droughts spanning consecutive long and short rains seasons over eastern Africa. The increased frequency of dry conditions is linked to warming SSTs over the Indo-west Pacific and to a lesser degree to Pacific Decadal Variability. During MAM, long-term warming of tropical west Pacific SSTs from 1950–2010 has forced statistically significant precipitation reductions over eastern Africa. The warming west Pacific SSTs have forced changes in the regional lower tropospheric circulation by weakening the Somali Jet, which has reduced moisture and rainfall over the Horn of Africa. During OND, reductions in precipitation over recent decades are oftentimes overshadowed by strong year-to-year precipitation variability forced by the Indian Ocean Dipole and the El Niño–Southern Oscillation.

  3. PET imaging of early response to the tyrosine kinase inhibitor ZD4190

    International Nuclear Information System (INIS)

    Yang, Min; Gao, Haokao; Yan, Yongjun; Sun, Xilin; Chen, Kai; Quan, Qimeng; Lang, Lixin; Kiesewetter, Dale; Niu, Gang; Chen, Xiaoyuan

    2011-01-01

    We evaluated noninvasive positron emission tomography (PET) imaging for monitoring tumor response to the VEGFR-2 tyrosine kinase (TK) inhibitor ZD4190 during cancer therapy. Orthotopic MDA-MB-435 tumor-bearing mice were treated with ZD4190 (100 mg/kg orally per day for three consecutive days). Tumor growth was monitored by caliper measurement. During the therapeutic period, longitudinal PET scans were acquired using 18 F-FDG, 18 F-FLT and 18 F-FPPRGD2 as imaging tracers to evaluate tumor glucose metabolism, tumor cell proliferation, and angiogenesis, respectively. Imaging metrics were validated by immunohistochemical analysis of Ki67, GLUT-1, F4/80, CD31, murine integrin β3, and human integrin αvβ3. Three consecutive daily oral administrations of 100 mg/kg of ZD4190 were effective in delaying MDA-MB-435 tumor growth. A significant difference in tumor volume was observed on day 7 between the treatment group and the control group (p 18 F-FPPRGD2 uptake was stable between days 0 and 7. In ZD4190-treated tumors, 18 F-FPPRGD2 uptake had decreased significantly relative to baseline by 26.74±8.12% (p 18 F-FLT had also decreased on both day 1 and day 3 after initiation of ZD4190 treatment. No significant change in 18 F-FDG uptake in ZD4190-treated tumors was observed, however, compared with the control group. All of the imaging findings were supported by ex vivo analysis of related biomarkers. The longitudinal imaging results demonstrated the usefulness of quantitative 18 F-FLT and 18 F-FPPRGD2 PET imaging in evaluating the early antiproliferative and antiangiogenic effects of ZD4190. The quantification data from the PET imaging were consistent with the pattern of initial growth inhibition with treatment, followed by tumor relapse after treatment cessation. (orig.)

  4. SOLUTION OF SIGNAL UNCERTAINTY PROBLEM AT ANALYTICAL DESIGN OF CONSECUTIVE COMPENSATOR IN PIEZO ACTUATOR CONTROL

    Directory of Open Access Journals (Sweden)

    S.V. Bystrov

    2016-05-01

    Full Text Available Subject of Research.We present research results for the signal uncertainty problem that naturally arises for the developers of servomechanisms, including analytical design of serial compensators, delivering the required quality indexes for servomechanisms. Method. The problem was solved with the use of Besekerskiy engineering approach, formulated in 1958. This gave the possibility to reduce requirements for input signal composition of servomechanisms by using only two of their quantitative characteristics, such as maximum speed and acceleration. Information about input signal maximum speed and acceleration allows entering into consideration the equivalent harmonic input signal with calculated amplitude and frequency. In combination with requirements for maximum tracking error, the amplitude and frequency of the equivalent harmonic effects make it possible to estimate analytically the value of the amplitude characteristics of the system by error and then convert it to amplitude characteristic of open-loop system transfer function. While previously Besekerskiy approach was mainly used in relation to the apparatus of logarithmic characteristics, we use this approach for analytical synthesis of consecutive compensators. Main Results. Proposed technique is used to create analytical representation of "input–output" and "error–output" polynomial dynamic models of the designed system. In turn, the desired model of the designed system in the "error–output" form of analytical representation of transfer functions is the basis for the design of consecutive compensator, that delivers the desired placement of state matrix eigenvalues and, consequently, the necessary set of dynamic indexes for the designed system. The given procedure of consecutive compensator analytical design on the basis of Besekerskiy engineering approach under conditions of signal uncertainty is illustrated by an example. Practical Relevance. The obtained theoretical results are

  5. A PET/CT-based strategy is a stronger predictor of survival than a standard imaging strategy in patients with head and neck squamous cell carcinoma

    DEFF Research Database (Denmark)

    Rohde, Max; Nielsen, Anne L; Pareek, Manan

    2018-01-01

    Purpose: To examine whether tumor staging by upfront (18)F-fluoro-deoxy-glucose-positron emission tomography/computed tomography (PET/CT) leads to improved discrimination of survival, when compared with traditionally used imaging strategies based on chest X-ray + head and neck magnetic resonance...... imaging (CXR/MRI) or chest computed tomography + head and neck MRI (CCT/MRI) in patients with head and neck squamous cell carcinoma (HNSCC). Methods: Blinded prospective cohort study based on paired data. Consecutive patients with histologically verified primary HNSCC were recruited at Odense University...

  6. Study about Illness: Through the Narrative of "Illness Image"

    OpenAIRE

    岩城, 晶子

    2013-01-01

    In this research, the meaning of the illness was studied from the perpective of Image. From listening to the narrative about two types of Illness Image, i.e., "my illness" and "A's illness, " we found that there was a characteristic that the Illness Image was similar to the real image. In addition, there were several differences between 2 images, which indicated that distance between the narrator and these images had an influence. From the syudy of two cases, it was indicated that Illness Ima...

  7. Similar long-term survival of consecutive in-hospital and out-of-hospital cardiac arrest patients treated with targeted temperature management

    DEFF Research Database (Denmark)

    Engsig, Magaly; Søholm, Helle; Folke, Fredrik

    2016-01-01

    OBJECTIVE: The long-term survival of in-hospital cardiac arrest (IHCA) patients treated with targeted temperature management (TTM) is poorly described. The aim of this study was to compare the outcomes of consecutive IHCA with out-of-hospital cardiac arrest (OHCA) patients treated with TTM. DESIGN...... SETTING AND PATIENTS: Retrospectively collected data on all consecutive adult patients treated with TTM at a university tertiary heart center between 2005 and 2011 were analyzed. MEASUREMENTS: Primary endpoints were survival to hospital discharge and long-term survival. Secondary endpoint was neurological...... time to return of spontaneous circulation (ROSC). Survival to hospital discharge was 54% for OHCA and 53% for IHCA (adjusted odds ratio 0.98 [95% confidence interval {CI}; 0.43-2.24]). Age ≤60 years, bystander CPR, time to ROSC ≤10 min, and shockable rhythm at presentation were associated with survival...

  8. Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage

    International Nuclear Information System (INIS)

    Bonatti, Matteo; Pernter, Patrizia; Bonatti, Giampietro; Lombardo, Fabio; Zamboni, Giulia A.; Pozzi Mucelli, Roberto

    2017-01-01

    To evaluate the diagnostic performance of virtual non-contrast (VNC) images in detecting intracranial haemorrhages (ICHs). Sixty-seven consecutive patients with and 67 without ICH who underwent unenhanced brain CT and DECT angiography were included. Two radiologists independently evaluated VNC and true non-contrast (TNC) images for ICH presence and type. Inter-observer agreement for VNC and TNC image evaluation was calculated. Sensitivity and specificity of VNC images for ICH detection were calculated using Fisher's exact test. VNC and TNC images were compared for ICH extent (qualitatively and quantitatively) and conspicuity assessment. On TNC images 116 different haemorrhages were detected in 67 patients. Inter-observer agreement ranged from 0.98-1.00 for TNC images and from 0.86-1.00 for VNC images. VNC sensitivity ranged from 0.90-1, according to the different ICH types, and specificity from 0.97-1. Qualitatively, ICH extent was underestimated on VNC images in 11.9% of cases. Haemorrhage volume did not show statistically significant differences between VNC and TNC images. Mean haemorrhage conspicuity was significantly lower on VNC images than on TNC images for both readers (p < 0.001). VNC images are accurate for ICH detection. Haemorrhages are less conspicuous on VNC images and their extent may be underestimated. (orig.)

  9. Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Bonatti, Matteo; Pernter, Patrizia; Bonatti, Giampietro [Bolzano Central Hospital, Department of Radiology, Bolzano (Italy); Lombardo, Fabio; Zamboni, Giulia A.; Pozzi Mucelli, Roberto [University of Verona, Department of Radiology, Verona (Italy)

    2017-07-15

    To evaluate the diagnostic performance of virtual non-contrast (VNC) images in detecting intracranial haemorrhages (ICHs). Sixty-seven consecutive patients with and 67 without ICH who underwent unenhanced brain CT and DECT angiography were included. Two radiologists independently evaluated VNC and true non-contrast (TNC) images for ICH presence and type. Inter-observer agreement for VNC and TNC image evaluation was calculated. Sensitivity and specificity of VNC images for ICH detection were calculated using Fisher's exact test. VNC and TNC images were compared for ICH extent (qualitatively and quantitatively) and conspicuity assessment. On TNC images 116 different haemorrhages were detected in 67 patients. Inter-observer agreement ranged from 0.98-1.00 for TNC images and from 0.86-1.00 for VNC images. VNC sensitivity ranged from 0.90-1, according to the different ICH types, and specificity from 0.97-1. Qualitatively, ICH extent was underestimated on VNC images in 11.9% of cases. Haemorrhage volume did not show statistically significant differences between VNC and TNC images. Mean haemorrhage conspicuity was significantly lower on VNC images than on TNC images for both readers (p < 0.001). VNC images are accurate for ICH detection. Haemorrhages are less conspicuous on VNC images and their extent may be underestimated. (orig.)

  10. In vivo retinal imaging for fixational eye motion detection using a high-speed digital micromirror device (DMD)-based ophthalmoscope.

    Science.gov (United States)

    Vienola, Kari V; Damodaran, Mathi; Braaf, Boy; Vermeer, Koenraad A; de Boer, Johannes F

    2018-02-01

    Retinal motion detection with an accuracy of 0.77 arcmin corresponding to 3.7 µm on the retina is demonstrated with a novel digital micromirror device based ophthalmoscope. By generating a confocal image as a reference, eye motion could be measured from consecutively measured subsampled frames. The subsampled frames provide 7.7 millisecond snapshots of the retina without motion artifacts between the image points of the subsampled frame, distributed over the full field of view. An ophthalmoscope pattern projection speed of 130 Hz enabled a motion detection bandwidth of 65 Hz. A model eye with a scanning mirror was built to test the performance of the motion detection algorithm. Furthermore, an in vivo motion trace was obtained from a healthy volunteer. The obtained eye motion trace clearly shows the three main types of fixational eye movements. Lastly, the obtained eye motion trace was used to correct for the eye motion in consecutively obtained subsampled frames to produce an averaged confocal image correct for motion artefacts.

  11. The effect of magnetic resonance imaging in a teaching hospital on patient management

    Energy Technology Data Exchange (ETDEWEB)

    Hailey, D M; Crowe, B L [Australian Inst. of Health, Canberra, ACT (Australia). Health Technology Div.; Burgess, I A [Royal North Shore Hospital, Crows Nest, NSW (Australia); Khangure, M S; Morris, I [Sir Charles Gairdner Hospital, Perth, WA (Australia). Dept. of Diagnostic Radiology

    1993-05-01

    An observational study was undertaken to obtain measures of the impact of magnetic resonance imaging (MRI) on diagnosis, patient management and patient outcome. A minimum data set at the time of examination was used for 1119 consecutive patients referred by specialists for MRI of the brain or spine. Three months follow up of 707 brain examinations and 235 spinal examinations were undertaken using a questionnaire on diagnosis and patient management. Magnetic resonance imaging made a dominant contribution to final diagnoses of neoplasia and vascular disorders, but was less significant for white matter disease. In a high proportion of cases other types of examination also influenced the final diagnosis. It was concluded that magnetic resonance imaging affected patient management in a high proportion of spinal examinations and in cases of cerebral neoplasm, with lesser contributions to cases of cerebrovascular disorder and white matter disease. While MRI was considered superior to other imaging methods, which it could often replace, in practice it will form only one input to the diagnostic decision. 7 refs., 3 tabs.

  12. The effect of magnetic resonance imaging in a teaching hospital on patient management

    International Nuclear Information System (INIS)

    Hailey, D.M.; Crowe, B.L.; Khangure, M.S.; Morris, I.

    1993-01-01

    An observational study was undertaken to obtain measures of the impact of magnetic resonance imaging (MRI) on diagnosis, patient management and patient outcome. A minimum data set at the time of examination was used for 1119 consecutive patients referred by specialists for MRI of the brain or spine. Three months follow up of 707 brain examinations and 235 spinal examinations were undertaken using a questionnaire on diagnosis and patient management. Magnetic resonance imaging made a dominant contribution to final diagnoses of neoplasia and vascular disorders, but was less significant for white matter disease. In a high proportion of cases other types of examination also influenced the final diagnosis. It was concluded that magnetic resonance imaging affected patient management in a high proportion of spinal examinations and in cases of cerebral neoplasm, with lesser contributions to cases of cerebrovascular disorder and white matter disease. While MRI was considered superior to other imaging methods, which it could often replace, in practice it will form only one input to the diagnostic decision. 7 refs., 3 tabs

  13. Dual-source CT coronary imaging in heart transplant recipients: image quality and optimal reconstruction interval

    International Nuclear Information System (INIS)

    Bastarrika, Gorka; Arraiza, Maria; Pueyo, Jesus C.; Cecco, Carlo N. de; Ubilla, Matias; Mastrobuoni, Stefano; Rabago, Gregorio

    2008-01-01

    The image quality and optimal reconstruction interval for coronary arteries in heart transplant recipients undergoing non-invasive dual-source computed tomography (DSCT) coronary angiography was evaluated. Twenty consecutive heart transplant recipients who underwent DSCT coronary angiography were included (19 male, one female; mean age 63.1±10.7 years). Data sets were reconstructed in 5% steps from 30% to 80% of the R-R interval. Two blinded independent observers assessed the image quality of each coronary segments using a five-point scale (from 0 = not evaluative to 4=excellent quality). A total of 289 coronary segments in 20 heart transplant recipients were evaluated. Mean heart rate during the scan was 89.1±10.4 bpm. At the best reconstruction interval, diagnostic image quality (score ≥2) was obtained in 93.4% of the coronary segments (270/289) with a mean image quality score of 3.04± 0.63. Systolic reconstruction intervals provided better image quality scores than diastolic reconstruction intervals (overall mean quality scores obtained with the systolic and diastolic reconstructions 3.03±1.06 and 2.73±1.11, respectively; P<0.001). Different systolic reconstruction intervals (35%, 40%, 45% of RR interval) did not yield to significant differences in image quality scores for the coronary segments (P=0.74). Reconstructions obtained at the systolic phase of the cardiac cycle allowed excellent diagnostic image quality coronary angiograms in heart transplant recipients undergoing DSCT coronary angiography. (orig.)

  14. Mediating Peer Teaching for Learning Games: An Action Research Intervention Across Three Consecutive Sport Education Seasons.

    Science.gov (United States)

    Farias, Cláudio; Mesquita, Isabel; Hastie, Peter A; O'Donovan, Toni

    2018-03-01

    The purpose of this study was to provide an integrated analysis of a teacher's peer-teaching mediation strategies, the student-coaches' instruction, and the students' gameplay development across 3 consecutive seasons of sport education. Twenty-six 7th-grade students participated in 3 consecutive sport education seasons of invasion games (basketball, handball, and soccer). The research involved 3 action research cycles, 1 per season, and each cycle included the processes of planning, acting and monitoring, reflecting, and fact finding. Data collection consisted of videotape and audiotape records of all 47 lessons, a reflective field diary kept by the first author in the role of teacher-researcher, and a total of 24 semistructured focus-group interviews. Trustworthiness criteria for assuring the quality of qualitative research included extensive data triangulation, stakeholders' crosschecking, and collaborative interpretational analysis. Through the application of systematic preparation strategies, student-coaches were able to successfully conduct team instruction that resulted in students' tactical development and improved performance. Aspects such as the study of predominant configurations of players' gameplay and similar tactical principles across games within the same category prevented a setback in the complexity of the learning content addressed at the beginning of each season. Players also showed an increasing ability to adapt gameplay to game conditions. While sport education has the capacity to develop competent players, different levels of teacher guidance and learners' instructional responsibility are necessary when teaching tactics.

  15. De novo achondroplasia causing four consecutive unsuccessful pregnancies: a case report

    Directory of Open Access Journals (Sweden)

    Igwegbe Anthony

    2012-08-01

    Full Text Available Abstract Introduction The incidence of achondroplasia is very low, and the birth of two or more consecutive babies with achondroplasia to unaffected parents is a rarity. We report a rare case of recurrent achondroplasia in babies of unaffected parents. Case presentation A 29-year-old Nigerian Igbo woman who has had three consecutive dead achondroplastic babies presented at a gestational age of 31 weeks with a two-hour history of drainage of liquor and vaginal bleeding. Neither she nor her husband had features of achondroplasia. Fundal height was compatible with the gestational age. Fetal heart activity was present. An abdominal ultrasound examination showed a viable fetus with short long bones, oligohydramnios, and a fundal placenta with a small retroplacental blood clot. Our patient was stabilized and had an emergency Cesarean section for grade 1 abruptio placentae. A live male baby with Apgar scores of 4 at one minute and 5 at 10 minutes was delivered. The baby had classic features of achondroplasia and died shortly after birth. Conclusions To the best of our knowledge, this is the first reported case of recurrent achondroplasia in siblings of unaffected parents in Nigeria. Management is challenging, and the outcomes of future pregnancies appear bleak. However, proper counseling and follow-up are needed. There is also a need to establish preconception clinics and facilities for prenatal genetic diagnosis and gene therapy in developing countries.

  16. The 5x1 DAFNE study protocol: a cluster randomised trial comparing a standard 5 day DAFNE course delivered over 1 week against DAFNE training delivered over 1 day a week for 5 consecutive weeks

    Directory of Open Access Journals (Sweden)

    Elliott Jackie

    2012-11-01

    Full Text Available Abstract Background Structured education programmes are now established as an essential component to assist effective self-management of diabetes. In the case of Type 1 diabetes, the Dose Adjustment For Normal Eating (DAFNE programme improves both glycaemic control and quality of life. Traditionally delivered over five consecutive days, this format has been cited as a barrier to participation by some patients, such as those who work full-time. Some centres in the UK have organised structured education programmes to be delivered one day a week over several consecutive weeks. This type of format may add benefit by allowing more time in which to practice skills between sessions, but may suffer as a result of weaker peer support being generated compared to that formed over five consecutive days. Methods/design We aim to compare DAFNE delivered over five consecutive days (1 week course with DAFNE delivered one day a week over five weeks (5 week course in a randomised controlled trial. A total of 213 patients were randomised to attend either a 1 week or a 5 week course delivered in seven participating centres. Study outcomes (measured at baseline, 6 and 12 months post-course include HbA1c, weight, self-reported rates of severe hypoglycaemia, psychosocial measures of quality of life, and cost-effectiveness. Generalisability was optimised by recruiting patients from DAFNE waiting lists at each centre, and by mailing eligible patients from hospital clinic lists. The inclusion and exclusion criteria were identical to those used to recruit to a standard DAFNE course (e.g., HbA1c Discussion This trial has been designed to test the hypothesis that the benefits of delivering a structured education programme over 5 weeks are comparable to those observed after a 1 week course. The results of the trial and the qualitative sub-study will both inform the design and delivery of future DAFNE courses, and the development of structured education programmes in other

  17. Imaging from cystic fibrosis

    International Nuclear Information System (INIS)

    Schmidt, H.; Posselt, H.G.

    2008-01-01

    Cystic fibrosis (CF) is the most frequent metabolic disorder with autosomal recessive inheritance in the Caucasian population. The gene defect is located on the long arm of chromosome 7. In Germany today, the actual median survival is 37 years. The genetic defect caused by chloride anion disturbances affects multiple body systems but the morbidity and mortality is due to lung disease. The secretion of highly viscous mucus promotes viral and bacterial pulmonary infections leading to airway obstruction and consecutive destruction of the lung parenchyma. This article will review and discuss both the clinical aspects of the disease and the diagnostic methods, referring in particular to new imaging strategies. (orig.)

  18. Reliability of perfluoroalkyl substances in plasma of 100 women in two consecutive pregnancies

    Science.gov (United States)

    Papadopoulou, Eleni; Haug, Line S.; Sabaredzovic, Azemira; Eggesbø, Merete; Longnecker, Matthew P.

    2015-01-01

    The potential toxicity of background exposure to perfluoroalkyl substances (PFASs) is currently under active investigation. Such investigations typically rely on a single measure of PFAS concentration, yet the longer-term reliability of a single measure has not been well characterized, especially among reproductive-aged women. Our aim was to investigate the association between PFAS plasma concentrations of 100 women in two consecutive pregnancies and explore changes in plasma concentration related to reproductive factors. The women in our study were enrolled in the Norwegian Mother and Child Cohort Study (MoBa) from 2003 to 2009. About half of them breastfed exclusively for 6 months and the rest of the participants did not breastfeed between the two consecutive pregnancies (median time between pregnancies: 18 months). Maternal blood was collected at mid-pregnancy and plasma was analyzed for 10 PFASs. Statistical analyses were restricted to 6 PFASs that were quantifiable in more than 80% of the samples. We estimated the correlation between repeated PFAS measurements, the percentage change between pregnancies and the effect of several reproductive factors in multivariate linear regression models of PFAS concentration in the second pregnancy. The Pearson correlation coefficient between repeated PFAS measurements was, for perfluorooctane sulfonate (PFOS), 0.80; perfluorooctanoate (PFOA), 0.50; perfluorohexane sulfonate (PFHxS), 0.74; perfluorononanoate (PFNA), 0.39; perfluoroundecanoate (PFUnDA), 0.71; and perfluorodecanoate (PFDA), 0.60. Adjustment for maternal age, delivery year, and time and breastfeeding between pregnancies did not substantially affect the observed correlations. We found 44-47% median reductions in the concentrations of PFOS, PFOA and PFHxS between pregnancies, while the change in concentrations between pregnancies was smaller and more variable for PFNA, PFUnDA and PFDA. The variation in plasma concentrations in the second pregnancy was mainly

  19. Challenges in clinical studies with multiple imaging probes

    International Nuclear Information System (INIS)

    Krohn, Kenneth A.; O'Sullivan, Finbarr; Crowley, John; Eary, Janet F.; Linden, Hannah M.; Link, Jeanne M.; Mankoff, David A.; Muzi, Mark; Rajendran, Joseph G.; Spence, Alexander M.; Swanson, Kristin R.

    2007-01-01

    This article addresses two related issues: (a) When a new imaging agent is proposed, how does the imager integrate it with other biomarkers, either sampled or imaged? (b) When we have multiple imaging agents, is the information additive or duplicative and how is this objectively determined? Molecular biology is leading to new treatment options with reduced normal tissue toxicity, and imaging should have a role in objectively evaluating new treatments. There are two roles for molecular characterization of disease. Molecular imaging measurements before therapy help predict the aggressiveness of disease and identify therapeutic targets and, therefore, help choose the optimal therapy for an individual. Measurements of specific biochemical processes made during or after therapy should be sensitive measures of tumor response. The rules of evidence are not fully developed for the prognostic role of imaging biomarkers, but the potential of molecular imaging provides compelling motivation to push forward with convincing validation studies. New imaging procedures need to be characterized for their effectiveness under realistic clinical conditions to improve the management of patients and achieve a better outcome. The purpose of this article is to promote a critical discussion within the molecular imaging community because our future value to the overall biomedical community will be in supporting better treatment outcomes rather than in detection

  20. A time and imaging cost analysis of low-risk ED observation patients: a conservative 64-section computed tomography coronary angiography "triple rule-out" compared to nuclear stress test strategy.

    Science.gov (United States)

    Takakuwa, Kevin M; Halpern, Ethan J; Shofer, Frances S

    2011-02-01

    The study aimed to examine time and imaging costs of 2 different imaging strategies for low-risk emergency department (ED) observation patients with acute chest pain or symptoms suggestive of acute coronary syndrome. We compared a "triple rule-out" (TRO) 64-section multidetector computed tomography protocol with nuclear stress testing. This was a prospective observational cohort study of consecutive ED patients who were enrolled in our chest pain observation protocol during a 16-month period. Our standard observation protocol included a minimum of 2 sets of cardiac enzymes at least 6 hours apart followed by a nuclear stress test. Once a week, observation patients were offered a TRO (to evaluate for coronary artery disease, thoracic dissection, and pulmonary embolus) multidetector computed tomography with the option of further stress testing for those patients found to have evidence of coronary artery disease. We analyzed 832 consecutive observation patients including 214 patients who underwent the TRO protocol. Mean total length of stay was 16.1 hours for TRO patients, 16.3 hours for TRO plus other imaging test, 22.6 hours for nuclear stress testing, 23.3 hours for nuclear stress testing plus other imaging tests, and 23.7 hours for nuclear stress testing plus TRO (P < .0001 for TRO and TRO + other test compared to stress test ± other test). Mean imaging times were 3.6, 4.4, 5.9, 7.5, and 6.6 hours, respectively (P < .05 for TRO and TRO + other test compared to stress test ± other test). Mean imaging costs were $1307 for TRO patients vs $945 for nuclear stress testing. Triple rule-out reduced total length of stay and imaging time but incurred higher imaging costs. A per-hospital analysis would be needed to determine if patient time savings justify the higher imaging costs. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Post double-contrast sigmoid flush: An adjuvant technique in imaging diverticular disease

    International Nuclear Information System (INIS)

    Lappas, J.C.; Maglinte, D.D.T.; Kopecky, K.K.; Cockerill, E.M.; Lehman, G.A.

    1987-01-01

    In a prospective study, the effect of a low-density contrast medium infusion was evaluated as an adjunct to high-density double-contrast medium sigmoid imaging. Following a double-contrast medium barium enema (DCBE), 52 consecutive patients with sigmoid diverticulosis received an additional 500-700-mL enema with either water or a 1.5%CT barium suspension. Rectosigmoid films were evaluated for luminal distention, visualization of the interhaustral space, definition of diverticula, and interpretation of polypoid defects. While double-contrast medium views were excellent in 21%, improvement in multiple factors by water or 1.5% barium flush resulted in improved sigmoid images in 65% and 73% of patients, respectively. Polyps may be confirmed and artifactual defects confidently excluded. Sigmoid flush, particularly with low-density barium, is a simple adjunct to DCBE that improves visualization of the diverticular sigmoid

  2. A Study on the Improvement of Digital Periapical Images using Image Interpolation Methods

    International Nuclear Information System (INIS)

    Song, Nam Kyu; Koh, Kwang Joon

    1998-01-01

    Image resampling is of particular interest in digital radiology. When resampling an image to a new set of coordinate, there appears blocking artifacts and image changes. To enhance image quality, interpolation algorithms have been used. Resampling is used to increase the number of points in an image to improve its appearance for display. The process of interpolation is fitting a continuous function to the discrete points in the digital image. The purpose of this study was to determine the effects of the seven interpolation functions when image resampling in digital periapical images. The images were obtained by Digora, CDR and scanning of Ektaspeed plus periapical radiograms on the dry skull and human subject. The subjects were exposed to intraoral X-ray machine at 60 kVp and 70 kVp with exposure time varying between 0.01 and 0.50 second. To determine which interpolation method would provide the better image, seven functions were compared ; (1) nearest neighbor (2) linear (3) non-linear (4) facet model (5) cubic convolution (6) cubic spline (7) gray segment expansion. And resampled images were compared in terms of SNR (Signal to Noise Ratio) and MTF (Modulation Transfer Function) coefficient value. The obtained results were as follows ; 1. The highest SNR value (75.96 dB) was obtained with cubic convolution method and the lowest SNR value (72.44 dB) was obtained with facet model method among seven interpolation methods. 2. There were significant differences of SNR values among CDR, Digora and film scan (P 0.05). 4. There were significant differences of MTF coefficient values between linear interpolation method and the other six interpolation methods (P<0.05). 5. The speed of computation time was the fastest with nearest neighbor method and the slowest with non-linear method. 6. The better image was obtained with cubic convolution, cubic spline and gray segment method in ROC analysis. 7. The better sharpness of edge was obtained with gray segment expansion method

  3. Evaluation of a HDR image sensor with logarithmic response for mobile video-based applications

    Science.gov (United States)

    Tektonidis, Marco; Pietrzak, Mateusz; Monnin, David

    2017-10-01

    The performance of mobile video-based applications using conventional LDR (Low Dynamic Range) image sensors highly depends on the illumination conditions. As an alternative, HDR (High Dynamic Range) image sensors with logarithmic response are capable to acquire illumination-invariant HDR images in a single shot. We have implemented a complete image processing framework for a HDR sensor, including preprocessing methods (nonuniformity correction (NUC), cross-talk correction (CTC), and demosaicing) as well as tone mapping (TM). We have evaluated the HDR sensor for video-based applications w.r.t. the display of images and w.r.t. image analysis techniques. Regarding the display we have investigated the image intensity statistics over time, and regarding image analysis we assessed the number of feature correspondences between consecutive frames of temporal image sequences. For the evaluation we used HDR image data recorded from a vehicle on outdoor or combined outdoor/indoor itineraries, and we performed a comparison with corresponding conventional LDR image data.

  4. Image based 3D city modeling : Comparative study

    Directory of Open Access Journals (Sweden)

    S. P. Singh

    2014-06-01

    Full Text Available 3D city model is a digital representation of the Earth’s surface and it’s related objects such as building, tree, vegetation, and some manmade feature belonging to urban area. The demand of 3D city modeling is increasing rapidly for various engineering and non-engineering applications. Generally four main image based approaches were used for virtual 3D city models generation. In first approach, researchers were used Sketch based modeling, second method is Procedural grammar based modeling, third approach is Close range photogrammetry based modeling and fourth approach is mainly based on Computer Vision techniques. SketchUp, CityEngine, Photomodeler and Agisoft Photoscan are the main softwares to represent these approaches respectively. These softwares have different approaches & methods suitable for image based 3D city modeling. Literature study shows that till date, there is no complete such type of comparative study available to create complete 3D city model by using images. This paper gives a comparative assessment of these four image based 3D modeling approaches. This comparative study is mainly based on data acquisition methods, data processing techniques and output 3D model products. For this research work, study area is the campus of civil engineering department, Indian Institute of Technology, Roorkee (India. This 3D campus acts as a prototype for city. This study also explains various governing parameters, factors and work experiences. This research work also gives a brief introduction, strengths and weakness of these four image based techniques. Some personal comment is also given as what can do or what can’t do from these softwares. At the last, this study shows; it concluded that, each and every software has some advantages and limitations. Choice of software depends on user requirements of 3D project. For normal visualization project, SketchUp software is a good option. For 3D documentation record, Photomodeler gives good

  5. Second Harmonic Generation Imaging Analysis of Collagen Arrangement in Human Cornea.

    Science.gov (United States)

    Park, Choul Yong; Lee, Jimmy K; Chuck, Roy S

    2015-08-01

    To describe the horizontal arrangement of human corneal collagen bundles by using second harmonic generation (SHG) imaging. Human corneas were imaged with an inverted two photon excitation fluorescence microscope. The excitation laser (Ti:Sapphire) was tuned to 850 nm. Backscatter signals of SHG were collected through a 425/30-nm bandpass emission filter. Multiple, consecutive, and overlapping image stacks (z-stacks) were acquired to generate three dimensional data sets. ImageJ software was used to analyze the arrangement pattern (irregularity) of collagen bundles at each image plane. Collagen bundles in the corneal lamellae demonstrated a complex layout merging and splitting within a single lamellar plane. The patterns were significantly different in the superficial and limbal cornea when compared with deep and central regions. Collagen bundles were smaller in the superficial layer and larger in deep lamellae. By using SHG imaging, the horizontal arrangement of corneal collagen bundles was elucidated at different depths and focal regions of the human cornea.

  6. MR imaging of intramedullary ischemia due to cervical spondylosis

    International Nuclear Information System (INIS)

    Dooms, G.; Mathurin, P.; Cornelis, G.; Hulcelle, P.

    1988-01-01

    A retrospective study was performed to assess the value of MR imaging for detecting intramedullary ischemia due to cervical spondylosis and to assess its clinical significance. One hundred consecutive unselected patients (70 men and 30 women, mean age = 62 years) were included in the study. All patients were treated surgically, either by anterior diskectomy and corporectomy or by posterior laminectomy. Clinical follow-up to 2 years was available for every patient. MR imaging was performed with a superconducting magnet (Philips Gyroscan S15) operating at 1.5T Sagittal T1-weighted (repetition time [TR] = 0.45 sec and echo time [TE] = 30 msec) and cardiac-gated T2-weighted (TR>1.2 sec and multiples TE of 50, 100 and 200 msc) imaging was performed in every patient. Cervical spondylosis was exquisitely demonstrated on MR images in every patient. With the sagittal plane, full extent and the degree of canalar stenosis were easily appreciated on T2-weighted images. A hyperintense intramedullary lesion was detected preoperatively in 24 of the patients and corresponded presumably to ischemic, edematous, and/or necrotic damage to the cord. It was usually located at the level or just below the level where the most severe canalar stenosis was demonstrated; it was identified only on T2-weighted images. In a comparison of the clinical outcome of the patients after surgery, there was a striking difference between the group of patients without and that with intramedullary lesions. In the first group, the relief of symptoms after surgery was partial or complete. In the other group, the clinical outcome was poor and symptom relief nearly absent. In conclusion, MR imaging is an exquisite modality for demonstrating necrotic intramedullary changes due to cervical spondylosis and thus may aid in determining the prognosis for surgery and clinical outcome of the patients

  7. Controlling spark timing for consecutive cycles to reduce the cyclic variations of SI engines

    International Nuclear Information System (INIS)

    Kaleli, Alirıza; Ceviz, Mehmet Akif; Erenturk, Köksal

    2015-01-01

    Minimization of the cyclic variations is one of the most important design goal for spark-ignited engines. Primary motivation of this study is to reduce the cyclic variations in spark ignition engines by controlling the spark timing for consecutive cycles. A stochastic model was performed between spark timing and in–cylinder maximum pressure by using the system identification techniques. The incylinder maximum pressure of the next cycle was predicted with this model. Minimum variance and generalized minimum variance controllers were designed to regulate the in–cylinder maximum pressure by changing the spark timing for consecutive cycles of the test engine. The produced control algorithms were built in LabView environment and installed to the Field Programmable Gate Arrays (FPGA) chassis. According to the test results, the in–cylinder maximum pressure of the next pressure cycle can be predicted fairly well, and the spark timing can be regulated to keep the in–cylinder maximum pressure in a desired band to reduce the cyclic variations. At fixed spark timing experiments, the COV Pmax and COV imep were 3.764 and 0.677%, whereas they decreased to 3.208 and 0.533% when GMV controller was applied, respectively. - Highlights: • Cycle per cycle spark timing control was carried out. • A stochastic process model was described between P max and the spark timing. • The cyclic variations in P max was decreased by keeping it in a desired band. • Different controllers were used to adjust spark timing signal of the next cycle. • COV Pmax was decreased by about 15% by using GMV controller

  8. Effectiveness of thin-slice axial images of multidetector row CT for visualization of bronchial artery before bronchial arterial embolization

    International Nuclear Information System (INIS)

    Shida, Yoshitaka; Hasuo, Kanehiro; Aibe, Hitoshi; Kubo, Yuko; Terashima, Kotaro; Kinjo, Maya; Kamano, H.; Yoshida, Atsuko

    2008-01-01

    We assessed the ability of visualization of bronchial artery (BA) by using thin-slice axial images of 4-detector multidetector row CT in 65 patients with hemoptysis. In all patients, the origins of BA were well identified with observation of consecutive axial images with 1 mm thickness by paging method and bronchial arterial embolization (BAE) was performed successfully. Thin-slice axial images were considered to be useful to recognize BA and to perform BAE in patients with hemoptysis. (author)

  9. Image-guided biopsy in patients with suspected ovarian carcinoma: a safe and effective technique?

    International Nuclear Information System (INIS)

    Griffin, Nyree; Grant, Lee A.; Freeman, Susan J.; Berman, Laurence H.; Sala, Evis; Jimenez-Linan, Mercedes; Earl, Helena; Ahmed, Ahmed Ashour; Crawford, Robin; Brenton, James

    2009-01-01

    In patients with suspected advanced ovarian carcinoma, a precise histological diagnosis is required before commencing neo-adjuvant chemotherapy. This study aims to determine the diagnostic accuracy and complication rate of percutaneous biopsies performed under ultrasound or computed tomography guidance. Between 2002 to 2007, 60 consecutive image-guided percutaneous biopsies were performed in patients with suspected ovarian cancer. The following variables were recorded: tissue biopsied, imaging technique, experience of operator, biopsy needle gauge, number of passes, complications, and final histology. Forty-seven patients had omental biopsies, 12 pelvic mass biopsies, and 1 para-aortic lymph node biopsy. Thirty-five biopsies were performed under ultrasound, 25 under computed tomography guidance. Biopsy needle gauges ranged from 14-20 swg with two to five passes for each patient. There were no complications. Histology was obtained in 52 (87%) patients. Percutaneous image-guided biopsy of peritoneal disease or pelvic mass is safe with high diagnostic accuracy. The large-gauge biopsy needle is as safe as the small gauge needle, but has the added value of obtaining tissue samples for immunohistochemistry and genomic studies. (orig.)

  10. Achieving interlocking nails without using an image intensifier.

    Science.gov (United States)

    Ikem, Innocent C; Ogunlusi, Johnson D; Ine, Henry R

    2007-08-01

    Interlocking nails are commonly performed using an image intensifier. These are expensive and are not readily available in most resource-poor countries of the world. The aim of this study was to achieve interlocking nailing without the use of an image intensifier. This is a prospective descriptive analysis of 40 consecutive cases seen with shaft fractures of the humerus, femur, and tibia. Fracture fixation was done using Surgical Implant Generation Network (SIGN) nails. Forty limbs in 34 patients were studied. There were 12 females and 22 males, giving a ratio of 1:2. The mean age (years) was 35.75+/-13.16 and the range was 17-70 years. The studied bones were: humerus 10%, femur 65%, and tibia 25%. The fracture lines were: transverse 40%, oblique 15%, and communited 45%. Fracture grades were: closed 90%, grade I, 5%, grade II, 2.5%, and grade IIIA, 2.5%. Surgical approaches were: antegrade 62.5% and retrograde 37.5%. Indications for fixation were: recent fracture 92.5%, non-union 5%, and malunion 3%. Methods of reductions were: open 85% and closed 15%. The mean follow-up period (years) was 1.50+/-0.78. The union time averaged 3 months. Complication was mainly screw loosening due to severe osteoporoses in one case. It is, therefore, concluded that, with the aid of external jigs and slot finders, interlocking can be achieved without an image intensifier.

  11. First clinical evaluation of a new single-use flexible ureteroscope (LithoVue™): a European prospective multicentric feasibility study

    NARCIS (Netherlands)

    Doizi, Steeve; Kamphuis, Guido; Giusti, Guido; Andreassen, Kim Hovgaard; Knoll, Thomas; Osther, Palle Jörn; Scoffone, Cesare; Pérez-Fentes, Daniel; Proietti, Silvia; Wiseman, Oliver; de la Rosette, Jean; Traxer, Olivier

    2017-01-01

    We evaluated a new digital single-use flexible ureteroscope, LithoVue™ with respect to deflection, image quality and maneuverability. A prospective cohort study was conducted in eight tertiary reference centers in Europe in December 2015 and January 2016. All consecutive patients included underwent

  12. Role of cranial imaging in epileptic status

    International Nuclear Information System (INIS)

    Nair, Pradeep P.; Kalita, Jayantee; Misra, Usha K.

    2009-01-01

    Introduction: There is paucity of studies evaluating the role of cranial imaging in the management of status epilepticus (SE); therefore this study evaluates the role of imaging in predicting the outcome of SE. Methods: Consecutive patients with SE were prospectively evaluated. Clinical evaluation, blood counts, serum chemistry and cerebrospinal fluid (CSF) were carried out. Cranial CT scan was performed on a spiral CT and MRI on a 1.5 T scanner. Patients were treated with IV sodium valproate, phenytoin and benzodiazepines as per fixed protocol. Outcome was defined as seizure control at 1 h and mortality. Various clinical and radiological parameters were correlated. Results: There were 99 patients with SE whose mean age was 35 (1-78) years, 40 females and 17 were below 12 years of age. Fifty six patients had central nervous system (CNS) infections, 15 strokes, 13 metabolic encephalopathy, 5 drug default and in the remaining 10 patients various acute symptomatic causes were present. Cranial imaging was abnormal in 59% patients. CT was abnormal in 21 (47.7%) out of 44 patients whereas MRI was abnormal in 26 (63.4%) out of 41 patients. Both MRI and CT were carried out in 14 patients and 12 revealed abnormalities; 2 had abnormality only on MRI. Imaging revealed cortical lesions in 10, subcortical in 19 and both cortical as well as subcortical in 30 patients. One hour seizure control was achieved in 60, seizures recurred within 24 h in 38 and 27 patients died during hospital stay. Seizure type, duration of SE, seizure control at 1 h and mortality did not correlate with radiological abnormalities. Conclusion: Cranial imaging reveals structural abnormality in 59% patients with SE and was not related to SE control and mortality.

  13. Role of cranial imaging in epileptic status

    Energy Technology Data Exchange (ETDEWEB)

    Nair, Pradeep P; Kalita, Jayantee [Department of Neurology, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow 226014 (India); Misra, Usha K. [Department of Neurology, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow 226014 (India)], E-mail: drukmisra@rediffmail.com

    2009-06-15

    Introduction: There is paucity of studies evaluating the role of cranial imaging in the management of status epilepticus (SE); therefore this study evaluates the role of imaging in predicting the outcome of SE. Methods: Consecutive patients with SE were prospectively evaluated. Clinical evaluation, blood counts, serum chemistry and cerebrospinal fluid (CSF) were carried out. Cranial CT scan was performed on a spiral CT and MRI on a 1.5 T scanner. Patients were treated with IV sodium valproate, phenytoin and benzodiazepines as per fixed protocol. Outcome was defined as seizure control at 1 h and mortality. Various clinical and radiological parameters were correlated. Results: There were 99 patients with SE whose mean age was 35 (1-78) years, 40 females and 17 were below 12 years of age. Fifty six patients had central nervous system (CNS) infections, 15 strokes, 13 metabolic encephalopathy, 5 drug default and in the remaining 10 patients various acute symptomatic causes were present. Cranial imaging was abnormal in 59% patients. CT was abnormal in 21 (47.7%) out of 44 patients whereas MRI was abnormal in 26 (63.4%) out of 41 patients. Both MRI and CT were carried out in 14 patients and 12 revealed abnormalities; 2 had abnormality only on MRI. Imaging revealed cortical lesions in 10, subcortical in 19 and both cortical as well as subcortical in 30 patients. One hour seizure control was achieved in 60, seizures recurred within 24 h in 38 and 27 patients died during hospital stay. Seizure type, duration of SE, seizure control at 1 h and mortality did not correlate with radiological abnormalities. Conclusion: Cranial imaging reveals structural abnormality in 59% patients with SE and was not related to SE control and mortality.

  14. Magnetic resonance imaging of the central nervous system. Comparison with X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Kajima, Toshio; Kagawa, Yoshihiro; Katsuta, Shizutomo.

    1987-06-01

    Magnetic resonance imaging (MRI) and X-ray computed tomography (X-ray CT) have been performed in 169 consecutive patients with central nervous system diseases. The findings from the two methods were compared for the capacity to defect lesions. Magnetic resonance imaging was more sensitive than or equivalent to X-ray CT in detecting lesions - especially detecting. Arnold-Chiari malformation, syringomyelia, spinal cord injury, and pituitary adenoma - in 158 patients (94 %). In six patients (10 %), lesion detection was possible only by MRI. Magnetic resonance imaging was inferior to X-ray CT in 11 patients (7 %) in detecting calcified lesions, meningioma, and cavernous hemangioma. (Namekawa, K.).

  15. Study on the usefulness of whole body SPECT coronal image, MIP image in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kawamura, Seiji

    2002-01-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with 67 Ga-citrate ( 67 Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  16. Twin-twin transfusion syndrome: cerebral ischemia is not the only fetal MR imaging finding

    Energy Technology Data Exchange (ETDEWEB)

    Kline-Fath, Beth M. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Cincinnati Children' s Hospital, Department of Radiology, Cincinnati, OH (United States); Calvo-Garcia, Maria A.; O' Hara, Sara M.; Racadio, Judy M. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Crombleholme, Timothy M. [University of Cincinnati Medical Center, Department of Surgery, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States)

    2007-01-15

    Twin-twin transfusion syndrome (TTTS) is a complication of monochorionic/diamniotic twin pregnancies. An imbalance of blood flow occurs through placental anastomoses, causing potentially significant morbidity and mortality in both twins. Although the sonographic findings of TTTS are well documented, we believe that MR imaging is a valuable adjunct. We describe the fetal MR imaging findings associated with TTTS. From 2003 to 2005, 37 consecutive MR imaging studies were performed on multiple-gestation pregnancies. Of the 37, 25 were consistent with TTTS, correlated and confirmed by sonographic criteria. MR fetal abnormalities were documented. Cerebral ischemia, which could not be demonstrated by sonography, was delineated well by MR imaging. New findings noted on fetal MR imaging were enlargement of cerebral venous sinuses in both twins, dilatation of the renal collecting system in the recipient, lung lesions in the recipient and cerebral malformations in the donor. MR imaging is an important adjunct in TTTS imaging. Its benefit over sonography is its clear definition of cerebral pathology, which is important for intervention and counseling. The new findings, particularly in the urinary tract and cerebral venous sinuses, also help support the diagnosis of TTTS and might reveal additional consequences of the altered hemodynamics that occur in TTTS. (orig.)

  17. Twin-twin transfusion syndrome: cerebral ischemia is not the only fetal MR imaging finding

    International Nuclear Information System (INIS)

    Kline-Fath, Beth M.; Calvo-Garcia, Maria A.; O'Hara, Sara M.; Racadio, Judy M.; Crombleholme, Timothy M.

    2007-01-01

    Twin-twin transfusion syndrome (TTTS) is a complication of monochorionic/diamniotic twin pregnancies. An imbalance of blood flow occurs through placental anastomoses, causing potentially significant morbidity and mortality in both twins. Although the sonographic findings of TTTS are well documented, we believe that MR imaging is a valuable adjunct. We describe the fetal MR imaging findings associated with TTTS. From 2003 to 2005, 37 consecutive MR imaging studies were performed on multiple-gestation pregnancies. Of the 37, 25 were consistent with TTTS, correlated and confirmed by sonographic criteria. MR fetal abnormalities were documented. Cerebral ischemia, which could not be demonstrated by sonography, was delineated well by MR imaging. New findings noted on fetal MR imaging were enlargement of cerebral venous sinuses in both twins, dilatation of the renal collecting system in the recipient, lung lesions in the recipient and cerebral malformations in the donor. MR imaging is an important adjunct in TTTS imaging. Its benefit over sonography is its clear definition of cerebral pathology, which is important for intervention and counseling. The new findings, particularly in the urinary tract and cerebral venous sinuses, also help support the diagnosis of TTTS and might reveal additional consequences of the altered hemodynamics that occur in TTTS. (orig.)

  18. Imaging inflammatory acne: lesion detection and tracking

    Science.gov (United States)

    Cula, Gabriela O.; Bargo, Paulo R.; Kollias, Nikiforos

    2010-02-01

    It is known that effectiveness of acne treatment increases when the lesions are detected earlier, before they could progress into mature wound-like lesions, which lead to scarring and discoloration. However, little is known about the evolution of acne from early signs until after the lesion heals. In this work we computationally characterize the evolution of inflammatory acne lesions, based on analyzing cross-polarized images that document acne-prone facial skin over time. Taking skin images over time, and being able to follow skin features in these images present serious challenges, due to change in the appearance of skin, difficulty in repositioning the subject, involuntary movement such as breathing. A computational technique for automatic detection of lesions by separating the background normal skin from the acne lesions, based on fitting Gaussian distributions to the intensity histograms, is presented. In order to track and quantify the evolution of lesions, in terms of the degree of progress or regress, we designed a study to capture facial skin images from an acne-prone young individual, followed over the course of 3 different time points. Based on the behavior of the lesions between two consecutive time points, the automatically detected lesions are classified in four categories: new lesions, resolved lesions (i.e. lesions that disappear completely), lesions that are progressing, and lesions that are regressing (i.e. lesions in the process of healing). The classification our methods achieve correlates well with visual inspection of a trained human grader.

  19. Prostate cancer in magnetic resonance imaging: diagnostic utilites of spectroscopic sequences

    International Nuclear Information System (INIS)

    Caivano, Rocchina; Cirillo, Patrizia; Lotumolo, Antonella; Fortunato, Giovanna; Zandolino, Alexis; Cammarota, Aldo; Balestra, Antonio; Macarini, Luca; Vita, Giulia

    2012-01-01

    The aim of our work is to determine the efficacy of a combined study 3 Tesla Magnetic Resonance Imaging (3T MRI), with phased-array coil, for the detection of prostate cancer using magnetic resonance spectroscopy (MRS) and diffusion-weighted images (DWI) in identifying doubt nodules. In this study, we prospectively studied 46 patients who consecutively underwent digital-rectal exploration for high doses of prostate specific antigen (PSA), as well as a MRI examination and a subsequent rectal biopsy. The study of magnetic resonance imaging was performed with a Philips Achieva 3T scanner and phased-array coil. The images were obtained with turbo spin-echo sequences T2-weighted images, T1-weighted before and after the administration of contrast medium, DWI sequences and 3D spectroscopic sequences. The ultrasound-guided prostate biopsy was performed approximately 15 days after the MRI. The data obtained from MR images and spectroscopy were correlated with histological data. MRI revealed sensitivity and specificity of 88% and 61% respectively and positive predictive value (PPV) of 73%, negative predicted value (NPV) of 81% and accuracy of 76%. In identifying the location of prostate cancer, the sensitivity of 3T MRS was 92%, with a specificity of 89%, PPV of 87%, NPV of 88% and accuracy of 87%; DWI showed a sensitivity of 88%, specificity of 61%, PPV of 73%, NPV of 81% and accuracy of 76%. The 3T MR study with phased-array coil and the use of DWI and spectroscopic sequences, in addition to T2-weighted sequences, revealed to be accurate in the diagnosis of prostate cancer and in the identification of nodules to be biopsied. It may be indicated as a resolute way before biopsy in patients with elevated PSA value and can be proposed in the staging and follow-up.

  20. Location of Rotator Cuff Tear Initiation: A Magnetic Resonance Imaging Study of 191 Shoulders.

    Science.gov (United States)

    Jeong, Jeung Yeol; Min, Seul Ki; Park, Keun Min; Park, Yong Bok; Han, Kwang Joon; Yoo, Jae Chul

    2018-03-01

    Degenerative rotator cuff tears (RCTs) are generally thought to originate at the anterior margin of the supraspinatus tendon. However, a recent ultrasonography study suggested that they might originate more posteriorly than originally thought, perhaps even from the isolated infraspinatus (ISP) tendon, and propagate toward the anterior supraspinatus. Hypothesis/Purpose: It was hypothesized that this finding could be reproduced with magnetic resonance imaging (MRI). The purpose was to determine the most common location of degenerative RCTs by using 3-dimensional multiplanar MRI reconstruction. It was assumed that the location of the partial-thickness tears would identify the area of the initiation of full-thickness tears. Cross-sectional study; Level of evidence, 3. A retrospective analysis was conducted including 245 patients who had RCTs (nearly full- or partial-thickness tears) at the outpatient department between January 2011 and December 2013. RCTs were measured on 3-dimensional multiplanar reconstruction MRI with OsiriX software. The width and distance from the biceps tendon to the anterior margin of the tear were measured on T2-weighted sagittal images. In a spreadsheet, columns of consecutive numbers represented the size of each tear (anteroposterior width) and their locations with respect to the biceps brachii tendon. Data were pooled to graphically represent the width and location of all tears. Frequency histograms of the columns were made to visualize the distribution of tears. The tears were divided into 2 groups based on width (group A, location related to size. The mean width of all RCTs was 11.9 ± 4.1 mm, and the mean length was 11.1 ± 5.0 mm. Histograms showed the most common location of origin to be 9 to 10 mm posterior to the biceps tendon. The histograms of groups A and B showed similar tear location distributions, indicating that the region approximately 10 mm posterior to the biceps tendon is the most common site of tear initiation. These

  1. Effect of consecutive re-synchronization protocols on pregnancy rate in buffalo (Bubalus bubalis) heifers out of the breeding season.

    Science.gov (United States)

    Neglia, Gianluca; Capuano, Massimo; Balestrieri, Anna; Cimmino, Roberta; Iannaccone, Francesco; Palumbo, Francesco; Presicce, Giorgio A; Campanile, Giuseppe

    2018-06-01

    The combined effect of six consecutive timed artificial inseminations (TAIs) on pregnancy rates, following two different synchronization protocols on buffalo heifers, over a period of seven months typically characterized by low breeding performances, were investigated in this study. A total of 2189 TAIs were performed on 1463 buffalo heifers within a large buffalo farm in the south of Italy. Individual animals were allowed to undergo synchronization protocol (either a slightly modified Ovsynch or Progesterone treatment) and TAI until establishment of pregnancy or else for not more than six consecutive times. Semen of seven proven bulls was used throughout the study, which was carried out from March to September of the same year. Therefore, other than the effect given by consecutive TAIs over time, a monthly and a seasonal effect could also be tested, once the entire period was split into a Low Breeding Season (LBS) from March to June, and a Transition to Breeding Season (TBS) from July to September. From the data recorded in this study and the statistical analysis performed, it can be stated that the two protocols for the synchronization of ovulation were similar in efficiency in determining pregnancies with an overall fertility rate of 89.4% when the comparison was run both on a monthly basis or when months were grouped into two different seasons. In addition, an average of 1.83 AI/pregnancy was reported, slightly higher for the Ovsynch when compared to the Progesterone protocol: 1.91 vs 1.70, respectively. Finally, when considering the number of progressive synchronization treatments implemented over time as covariate, neither Ovsynch nor Progesterone treatment significantly affected pregnancy rates following the first of the six synchronization sessions. However, repeating the synchronization procedure, the progesterone based protocol resulted in significantly higher probability of success in terms of established pregnancies during the second and third re

  2. Image quality of conventional images of dual-layer SPECTRAL CT: a phantom study.

    Science.gov (United States)

    van Ommen, F; Bennink, E; Vlassenbroek, A; Dankbaar, J W; Schilham, A M R; Viergever, M A; de Jong, H W A M

    2018-05-10

    Spectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips), by means of phantom experiments. For both CT scanners conventional CT images were acquired using four adult scanning protocols: i) body helical, ii) body axial, iii) head helical and iv) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. The resolution levels at 50%, 10% and 5% MTF of the iCT and IQon showed small but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with

  3. Non-mix fragrances are top sensitizers in consecutive dermatitis patients – a cross-sectional study of the 26 EU-labelled fragrance allergens

    DEFF Research Database (Denmark)

    Bennike, Niels H.; Zachariae, Claus; Johansen, Jeanne D.

    2017-01-01

    Background: For cosmetics, it is mandatory to label 26 fragrance substances, including all constituents of fragrance mix I (FM I) and fragrance mix II (FM II). Earlier reports have not included oxidized R-limonene [hydroperoxides of R-limonene (Lim-OOH)] and oxidized linalool [hydroperoxides...... patients were ‘FM II-negative but constituent-positive’ than ‘FM I-negative but constituent-positive’ (12.4% versus 3.2%, p = 0.0008). Conclusions: Non-mix fragrances are the most important single fragrance allergens among consecutive patients. The test concentration of the single FM I constituents should...

  4. Feasibility study on X-ray source with pinhole imaging method

    International Nuclear Information System (INIS)

    Qiu Rui; Li Junli

    2007-01-01

    In order to verify the feasibility of study on X-ray source with pinhole imaging method, and optimize the design of X-ray pinhole imaging system, an X-ray pinhole imaging equipment was set up. The change of image due to the change of the position and intensity of X-ray source was estimated with mathematical method and validated with experiment. The results show that the change of the spot position and gray of the spot is linearly related with the change of the position and intensity of X-ray source, so it is feasible to study X-ray source with pinhole imaging method in this application. The results provide some references for the design of X-ray pinhole imaging system. (authors)

  5. MR imaging of renal transplant rejection

    International Nuclear Information System (INIS)

    Hanna, S.; Helenon, O.; Legendre, C.; Chichie, J.F.; Di Stefano, D.; Kreis, H.; Moreau, J.F.; Hopital Necker, 75 - Paris

    1991-01-01

    The results of 62 consecutive MR examinations were correlated with the subsequent clinical course and histologic results. Twenty-six cases of rejection showed a marked diminution of cortico-medullary differentiation (CMD). The renal parenchymal vascular pattern and visibility of renal sinus fat were not markedly altered in rejection and there was no difference between normal and rejected allograft shape. The ability of MR imaging to diagnose renal transplant rejection is only based on CMD, which, however, is non-specific. In 2 cases of severe rejection, T2 weighted images showed an abnormal signal intensity of the cortex due to renal infarction. Our preliminary results in 8 patients with Gd-DOTA injection showed 2 cases with necrosis seen as areas with absent contrast enhancement. This technique seems to be promising in the detection of perfusion defects. (orig.)

  6. A longitudinal study of language learners’ images about Russia

    Directory of Open Access Journals (Sweden)

    Nikitina Larisa

    2016-05-01

    Full Text Available Several studies in the field of applied linguistics have explored images held by language learners about a target language country. However, for the most part, these studies focused on learners of modern European languages, such as German, Spanish and French and they were conducted in Western educational contexts. Besides, none of the previous investigations attempted to conduct a systematic classification of the language learners’ images. The present longitudinal study addressed these gaps in the research literature. It explored images about Russia held by Malaysian learners of the Russian language in a large university in East Malaysia. This article reports the findings of three questionnaire surveys conducted in 2004, 2007 and 2010. It was found that the images about Russia held by the participants were diverse and clustered around eight countryrelated aspects. Content of some categories of images was stable and changed little over time. Other categories were more fluid and more prone to change. The paper concludes with a discussion of pedagogical implications that can be derived from the findings.

  7. MR imaging of the brachial plexus: comparison between 1.5-T and 3-T MR imaging: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Tagliafico, Alberto; Neumaier, Carlo Emanuele; Calabrese, Massimo [National Institute for Cancer Research, Department of Radiology, Genova (Italy); Succio, Giulia; Serafini, Giovanni; Ghidara, Matteo [Santa Corona Hospital, Radiology Department, Savona (Italy); Martinoli, Carlo [Universita di Genova, Radiology Department, Genova (Italy)

    2011-06-15

    To compare 1.5-T and 3-T magnetic resonance (MR) imaging of the brachial plexus. Institutional review board approval and informed consent were obtained from 30 healthy volunteers and 30 consecutive patients with brachial plexus disturbances. MR was prospectively performed with comparable sequence parameters and coils with a 1.5-T and a 3-T system. Imaging protocols at both field strengths included T1-weighted turbo spin-echo (tSE) sequences and T2-weighed turbo spin-echo (tSE) sequences with fat saturation. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) between muscle and nerve were calculated for both field strengths. The visibility of brachial plexus nerve at various anatomic levels (roots, interscalene area, costoclavicular space, and axillary level) was analyzed with a four-point grading scale by two radiologists. MR imaging diagnoses and pathological findings were also compared qualitatively. SNR and CNRs were significantly higher on 3-T MR images than on 1.5-T MR images (Friedman test) for all sequences. Nerve visibility was significantly better on 3-T MR images than on 1.5-T MR images (paired sign test). Pathological findings (n = 30/30) were seen equally well with both field strengths. MR imaging diagnoses did not differ for the 1.5- and 3-T protocols. High-quality MR images of the brachial plexus can be obtained with 3-T MR imaging by using sequences similar to those used at 1.5-T MR imaging. In patients and healthy volunteers, the visibility of nerve trunks and cords at 3-T MR imaging appears to be superior to that at 1.5-T MR imaging. (orig.)

  8. Adult-onset intradural spinal teratoma: report of 18 consecutive cases and outcomes in a single center.

    Science.gov (United States)

    Wan, Wei; Yang, Cheng; Yan, Wangjun; Liu, Tielong; Yang, Xinghai; Song, Dianwen; Xiao, Jianru

    2017-07-01

    Eighteen consecutive patients with adult-onset intradural spinal teratoma underwent surgical treatment in our center from 1998 to 2013. Teratoma is defined as a neoplasm composed of elements derived from three germ cell layers (ectoderm, endoderm and mesoderm). Intraspinal teratoma is extremely rare and accounts for 0.2-0.5% of all spinal cord tumors. Moreover, teratoma occurs primarily in neonates and young children. Adult-onset intradural spinal teratoma is even rare. The aim of this study was to discuss the clinical characteristics, diagnosis and therapeutic strategies of adult-onset intradural spinal teratoma. This retrospective study included 18 consecutive adult patients with intradural teratoma who were surgically treated in our center between 1998 and 2013. The clinical features, pathogenesis, diagnostic strategies and surgical outcomes were discussed. Neurological function outcomes were evaluated by the JOA scoring system. Of the 18 included patients, 4 patients received subtotal resection and the other 14 patients received total resection. All the 18 cases were diagnosed with mature teratoma. The mean follow-up period was 79.7 (median 60.5; range 27-208) months. Local recurrence occurred in two of the four patients who underwent subtotal resection and in no patient who underwent total resection. The neurologic status improved in 16 cases and remained unchanged in the other two patients. Adult-onset intradural spinal teratoma is extremely rare. To the best of our knowledge, this is the largest series of patients with this disease. Despite the slow-growth and indolent nature, radical resection remains the recommended treatment to reduce tumor recurrence.

  9. [A computer-aided image diagnosis and study system].

    Science.gov (United States)

    Li, Zhangyong; Xie, Zhengxiang

    2004-08-01

    The revolution in information processing, particularly the digitizing of medicine, has changed the medical study, work and management. This paper reports a method to design a system for computer-aided image diagnosis and study. Combined with some good idea of graph-text system and picture archives communicate system (PACS), the system was realized and used for "prescription through computer", "managing images" and "reading images under computer and helping the diagnosis". Also typical examples were constructed in a database and used to teach the beginners. The system was developed by the visual developing tools based on object oriented programming (OOP) and was carried into operation on the Windows 9X platform. The system possesses friendly man-machine interface.

  10. Gender disparities in the association between epicardial adipose tissue volume and coronary atherosclerosis: a 3-dimensional cardiac computed tomography imaging study in Japanese subjects.

    Science.gov (United States)

    Dagvasumberel, Munkhbaatar; Shimabukuro, Michio; Nishiuchi, Takeshi; Ueno, Junji; Takao, Shoichiro; Fukuda, Daiju; Hirata, Yoichiro; Kurobe, Hirotsugu; Soeki, Takeshi; Iwase, Takashi; Kusunose, Kenya; Niki, Toshiyuki; Yamaguchi, Koji; Taketani, Yoshio; Yagi, Shusuke; Tomita, Noriko; Yamada, Hirotsugu; Wakatsuki, Tetsuzo; Harada, Masafumi; Kitagawa, Tetsuya; Sata, Masataka

    2012-09-10

    Growing evidence suggests that epicardial adipose tissue (EAT) may contribute to the development of coronary artery disease (CAD). In this study, we explored gender disparities in EAT volume (EATV) and its impact on coronary atherosclerosis. The study population consisted of 90 consecutive subjects (age: 63 ± 12 years; men: 47, women: 43) who underwent 256-slice multi-detector computed tomography (MDCT) coronary angiography. EATV was measured as the sum of cross-sectional epicardial fat area on CT images, from the lower surface of the left pulmonary artery origin to the apex. Subjects were segregated into the CAD group (coronary luminal narrowing > 50%) and non-CAD group. EATV/body surface area (BSA) was higher among men in the CAD group than in the non-CAD group (62 ± 13 vs. 33 ± 10 cm3/m2, p EATV/BSA was the single predictor for >50% coronary luminal narrowing in men (p EATV is strongly associated with coronary atherosclerosis in men.

  11. A Consecutive Spray Printing Strategy to Construct and Integrate Diverse Supercapacitors on Various Substrates.

    Science.gov (United States)

    Wang, Xinyu; Lu, Qiongqiong; Chen, Chen; Han, Mo; Wang, Qingrong; Li, Haixia; Niu, Zhiqiang; Chen, Jun

    2017-08-30

    The rapid development of printable electronic devices with flexible and wearable characteristics requires supercapacitor devices to be printable, light, thin, integrated macro- and micro-devices with flexibility. Herein, we developed a consecutive spray printing strategy to controllably construct and integrate diverse supercapacitors on various substrates. In such a strategy, all supercapacitor components are fully printable, and their thicknesses and shapes are well controlled. As a result, supercapacitors obtained by this strategy achieve diverse structures and shapes. In addition, different nanocarbon and pseudocapacitive materials are applicable for the fabrication of these diverse supercapacitors. Furthermore, the diverse supercapacitors can be readily constructed on various objects with planar, curved, or even rough surfaces (e.g., plastic film, glass, cloth, and paper). More importantly, the consecutive spray printing process can integrate several supercapacitors together in the perpendicular and parallel directions of one substrate by designing the structure of electrodes and separators. This enlightens the construction and integration of fully printable supercapacitors with diverse configurations to be compatible with fully printable electronics on various substrates.

  12. Dual-energy CT in patients with abdominal malignant lymphoma: impact of noise-optimised virtual monoenergetic imaging on objective and subjective image quality.

    Science.gov (United States)

    Lenga, L; Czwikla, R; Wichmann, J L; Leithner, D; Albrecht, M H; D'Angelo, T; Arendt, C T; Booz, C; Hammerstingl, R; Vogl, T J; Martin, S S

    2018-06-05

    To investigate the impact of noise-optimised virtual monoenergetic imaging (VMI+) reconstructions on quantitative and qualitative image parameters in patients with malignant lymphoma at dual-energy computed tomography (DECT) examinations of the abdomen. Thirty-five consecutive patients (mean age, 53.8±18.6 years; range, 21-82 years) with histologically proven malignant lymphoma of the abdomen were included retrospectively. Images were post-processed with standard linear blending (M_0.6), traditional VMI, and VMI+ technique at energy levels ranging from 40 to 100 keV in 10 keV increments. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were objectively measured in lymphoma lesions. Image quality, lesion delineation, and image noise were rated subjectively by three blinded observers using five-point Likert scales. Quantitative image quality parameters peaked at 40-keV VMI+ (SNR, 15.77±7.74; CNR, 18.27±8.04) with significant differences compared to standard linearly blended M_0.6 (SNR, 7.96±3.26; CNR, 13.55±3.47) and all traditional VMI series (ptraditional VMI at abdominal DECT examinations. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Image Transmission Studies

    Science.gov (United States)

    Blaine, G. James; Hill, Rexford L.; Rueter, Allen P.; Senol, Evren; Studt, James W.

    1988-06-01

    Radiological PACS image sizes and desired retrieval response times demand high-bandwidth communication networks. Local area network technology at speeds higher that 10 Megabits/second (IEEE 802.3) have not achieved standardization nor production volume. Our current PACS experiments are based on a three-level subnet approach using 10 Mb/s Ethernet channels. An Ethernet channel is shown to support image transfers at an average throughput of 3 Mb/s. Preliminary measurements and simulation results suggest that traffic from as many as two-to-three archives can be supported on the same channel.

  14. Comparative imaging study on monkeys with hemi-parkinsonism

    International Nuclear Information System (INIS)

    Wang Wei; Yu Xiaoping; Mao Jun; Liu Sheng; Wang Xiaoyi; Peng Guangchun; Wang Ruiwen

    2003-01-01

    Objective: To study the imaging appearance of experimental Parkinson's disease (PD) and to evaluate the different medical imaging exams on PD. Methods: CT, MRI, SPECT (dopamine transporter imaging and regional cerebral blood flow imaging, DAT imaging and rCBF imaging), and PET (glucose metabolism imaging) were performed on 8 monkeys before and after the infusion of MPTP into unilateral internal carotid artery to develop hemi-Parkinsonism models. Results: Hemi-Parkinsonism models were successfully induced on all 8 monkeys. On DAT imaging, the uptake values of the lesioned striatums decreased obviously after the MPTP treatment and were lower than that of the contralateral ones. The glucose metabolic rates of the lesioned striatums and thalamus in PD models were lower, compared to that of the healthy monkeys and that of the contralateral sides of themselves. Neither DAT nor glucose metabolism abnormalities was found on both the contralateral sides of the healthy and PD monkeys. On MRI images before MPTP treatment, only 4 of 8 PD models showed hypointense in bilateral globus pallidus. No abnormal MRI findings occurred in the first 2 months after injection of MPTP. At tile third month, hypointense appeared in globus pallidus of three monkeys. Enlarged hyposignal region in globus pallidus were found in three models. Of the above 6 monkeys, two appeared hypointense in putamina. Substantia nigra demonstrated no abnormalities before and after MPTP treatment. All rCBF and CT images were normal. Conclusion: The decreased density of DAT and decreased glucose metabolism on experimental PD can be showed early by DAT imaging and glucose metabolism imaging, MRI can show abnormal signal in the basal ganglia of PD but it is later than DAT and glucose metabolism imaging. CT and rCBF find no abnormality on PD

  15. SU-F-J-47: Inherent Uncertainty in the Positional Shifts Determined by a Volumetric Cone Beam Imaging System

    International Nuclear Information System (INIS)

    Giri, U; Ganesh, T; Saini, V; Munshi, A; Sarkar, B; Mohanti, B

    2016-01-01

    Purpose: To quantify inherent uncertainty associated with a volumetric imaging system in its determination of positional shifts. Methods: The study was performed on an Elekta Axesse™ linac’s XVI cone beam computed tomography (CBCT) system. A CT image data set of a Penta- Guide phantom was used as reference image by placing isocenter at the center of the phantom.The phantom was placed arbitrarily on the couch close to isocenter and CBCT images were obtained. The CBCT dataset was matched with the reference image using XVI software and the shifts were determined in 6-dimensions. Without moving the phantom, this process was repeated 20 times consecutively within 30 minutes on a single day. Mean shifts and their standard deviations in all 6-dimensions were determined for all the 20 instances of imaging. For any given day, the first set of shifts obtained was kept as reference and the deviations of the subsequent 19 sets from the reference set were scored. Mean differences and their standard deviations were determined. In this way, data were obtained for 30 consecutive working days. Results: Tabulating the mean deviations and their standard deviations observed on each day for the 30 measurement days, systematic and random errors in the determination of shifts by XVI software were calculated. The systematic errors were found to be 0.03, 0.04 and 0.03 mm while random errors were 0.05, 0.06 and 0.06 mm in lateral, craniocaudal and anterio-posterior directions respectively. For rotational shifts, the systematic errors were 0.02°, 0.03° and 0.03° and random errors were 0.06°, 0.05° and 0.05° in pitch, roll and yaw directions respectively. Conclusion: The inherent uncertainties in every image guidance system should be assessed and baseline values established at the time of its commissioning. These shall be periodically tested as part of the QA protocol.

  16. Extent of hypoattenuation on CT angiography source images in basilar artery occlusion: prognostic value in the Basilar Artery International Cooperation Study.

    Science.gov (United States)

    Puetz, Volker; Khomenko, Andrei; Hill, Michael D; Dzialowski, Imanuel; Michel, Patrik; Weimar, Christian; Wijman, Christine A C; Mattle, Heinrich P; Engelter, Stefan T; Muir, Keith W; Pfefferkorn, Thomas; Tanne, David; Szabo, Kristina; Kappelle, L Jaap; Algra, Ale; von Kummer, Ruediger; Demchuk, Andrew M; Schonewille, Wouter J

    2011-12-01

    The posterior circulation Acute Stroke Prognosis Early CT Score (pc-ASPECTS) quantifies the extent of early ischemic changes in the posterior circulation with a 10-point grading system. We hypothesized that pc-ASPECTS applied to CT angiography source images predicts functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). BASICS was a prospective, observational registry of consecutive patients with acute symptomatic basilar artery occlusion. Functional outcome was assessed at 1 month. We applied pc-ASPECTS to CT angiography source images of patients with CT angiography for confirmation of basilar artery occlusion. We calculated unadjusted and adjusted risk ratios (RRs) of pc-ASPECTS dichotomized at ≥8 versus <8. Primary outcome measure was favorable outcome (modified Rankin Scale scores 0-3). Secondary outcome measures were mortality and functional independence (modified Rankin Scale scores 0-2). Of 158 patients included, 78 patients had a CT angiography source images pc-ASPECTS≥8. Patients with a pc-ASPECTS≥8 more often had a favorable outcome than patients with a pc-ASPECTS<8 (crude RR, 1.7; 95% CI, 0.98-3.0). After adjustment for age, baseline National Institutes of Health Stroke Scale score, and thrombolysis, pc-ASPECTS≥8 was not related to favorable outcome (RR, 1.3; 95% CI, 0.8-2.2), but it was related to reduced mortality (RR, 0.7; 95% CI, 0.5-0.98) and functional independence (RR, 2.0; 95% CI, 1.1-3.8). In post hoc analysis, pc-ASPECTS dichotomized at ≥6 versus <6 predicted a favorable outcome (adjusted RR, 3.1; 95% CI, 1.2-7.5). pc-ASPECTS on CT angiography source images independently predicted death and functional independence at 1 month in the CT angiography subgroup of patients in the BASICS registry.

  17. The diagnostic value of adding dynamic scintigraphy to standard delayed planar imaging for sentinel node identification in melanoma patients

    International Nuclear Information System (INIS)

    Nielsen, Kristina Rue; Nielsen, Michael B.; Chakera, Annette H.; Hesse, Birger; Oturai, Peter S.; Scolyer, Richard A.; Stretch, Jonathan F.; Thompson, John F.; Uren, Roger F.

    2011-01-01

    The aim of this study was to compare early dynamic imaging combined with delayed static imaging and single photon emission computed tomography (SPECT)/CT with delayed, planar, static imaging alone for sentinel node (SN) identification in melanoma patients. Three hundred and seven consecutive melanoma patients referred for SN biopsy (SNB) were examined using combined imaging. Secondary interpretation of only the delayed static images was subsequently performed. In 220 patients (72%), complete surgical and pathological information relating to the SNB was available. The number of SNs identified and number of patients with positive SNs were compared between the two interpretations of the imaging studies and, when available, related to pathology data. A slightly higher number of SNs (mean 0.12/patient) was identified when interpreting only delayed static images compared to combined imaging. In a direct patient-to-patient comparison, the number of SN(s) identified on the combined vs static images only showed moderate agreement (kappa value 0.56). In 38 patients (17%), positive SNs were identified by the combined procedure compared to 35 (16%) by static imaging only. Thus by static imaging only, tumour-positive SNs were not identified in 3 of 38 patients (8%). For SN identification in melanoma patients, dynamic imaging combined with delayed static imaging and SPECT/CT is superior to delayed static imaging only because the latter is more likely to fail to identify SNs containing metastases. (orig.)

  18. Cardiac magnetic resonance imaging in patients with chest pain, high troponin levels and absence of coronary artery obstruction

    International Nuclear Information System (INIS)

    Avegliano, G.P.; Costabel, J.P.; Kuschnir, P.; Thierer, J.; Alves de Lima, A.; Sanchez, G.; Ronderos, J.; Huguet, M.; Petit, M.; Frangi, A.A.

    2011-01-01

    The prevalence of myocardial infarction with angiographically normal coronary arteries is approximately 7-10%. The etiological diagnosis is sometimes difficult and is important in terms of clinical practice and prognosis. The goal of our study was to show a series of consecutive patients with an initial diagnosis of acute coronary syndrome with high troponin levels and absence of coronary artery obstruction in which cardiac magnetic resonance imaging (CMRI) gave a description of the myocardial lesion, orientating towards the etiological diagnosis. From January 2005 to December 2009, 720 consecutive patients with an initial diagnosis of acute coronary syndrome and elevated troponins were included; 64 of these patients did not present angiographically significant coronary artery stenosis. Within 72 ± 24 h after coronary angiography, these patients underwent CMRI using b-SSFP sequences for cine imaging in short-axis, 2-, 3- and 4- chamber views for the evaluation of segmental wall motion, with T2-weighted and delayed enhancement (DE) images of the myocardium with an 'inversion-recovery' sequence. The following diagnoses were made: myocarditis (39 patients); myocardial infarction (12 patients); Tako-Tsubo syndrome (8 patients); apical hypertrophic cardiomyopathy (2 patients); 3 patients remained without diagnosis. These findings demonstrate the usefulness of CMRI in the clinical scenario of patients with chest pain, inconclusive ECG findings and high troponin levels with angiographically normal coronary arteries. The presence and distribution pattern of DE make it possible to define the etiological diagnosis and interpret the physiopathological process. (authors) [es

  19. The clinical utility of reduced-distortion readout-segmented echo-planar imaging in the head and neck region: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Koyasu, Sho; Iima, Mami; Umeoka, Shigeaki; Morisawa, Nobuko; Togashi, Kaori [Kyoto University, Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Porter, David A. [Siemens AG, MED MR PLM AW Neurology, Allee am Roethelheimpark 2, Erlangen (Germany); Ito, Juichi [Kyoto University, Department of Otolaryngology, Head and Neck Surgery, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Le Bihan, Denis [Kyoto University, Human Brain Research Center, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Neurospin, CEA-Saclay Center, Gif-sur-Yvette Cedex (France)

    2014-12-15

    To evaluate whether readout-segmented echo-planar imaging (RS-EPI) diffusion weighted image (DWI) can diminish image distortion in the head and neck area, compared with single-shot (SS)-EPI DWI. We conducted phantom and patient studies using 3 T magnetic resonance imaging (MRI) with a 16-channel coil. For the phantom study, we evaluated distortion and signal homogeneity in gel phantoms. For the patient study, 29 consecutive patients with clinically suspicious parotid lesions were prospectively enrolled. RS-EPI and SS-EPI DWI were evaluated by two independent readers for identification of organ/lesion and distortion, using semiquantitative scales and quantitative scores. Apparent diffusion coefficient (ADC) values and contrast-noise ratios of parotid tumours (if present; n = 15) were also compared. The phantom experiments showed that RS-EPI provided less distorted and more homogeneous ADC maps than SS-EPI. In the patient study, RS-EPI was found to provide significantly less distortion in almost all organs/lesions (p < 0.05), according to both semiquantitative scales and quantitative scores. There was no significant difference in ADC values and contrast-noise ratios between the two DWI techniques. The distortion in DWI was significantly reduced with RS-EPI in both phantom and patient studies. The RS-EPI technique provided more homogenous images than SS-EPI, and can potentially offer higher image quality in the head and neck area. (orig.)

  20. Abdominal MR imaging using a HASTE sequence : image comparison on the different echo times

    International Nuclear Information System (INIS)

    Park, Kwang Bo; Lee, Moon Gyu; Lim, Tae Hwan; Jeong, Yoong Ki; Ha, Hyun Kwon; Kim, Pyo Nyun; Auh, Yong Ho

    1999-01-01

    To determine the optimal parameters of abdominal HASTE imaging by means of a comparison of intermediate and long TE (echo time). We evaluated 30 consecutive patients who had undergone liver MR during a three-month period. Twelve patients were diagnosed as normal, four as having liver cirrhosis, and 14 were found to be suffering form hepatic hemangioma. On the basis of measured signal intensity of the liver, spleen, pancreas and gallbladder, and of fat, muscle, hemangioma, and background, we calculated the ratios of signal to noise (S/N), signal difference to noise (SD/N), and signal intensity (SI). Image quality was compared using these three ratios, and using two HASTE sequences with TEs of 90 msec and 134 msec, images were qualitatively evaluated. S/N ratio of the liver was higher when TE was 90 msec(p<.05), though S/N, SD/N and SI rations of the spleen, gallbladder, and pancreas-and of hemangiom-were higher when TE was 134 msec (p<.05). However, in muscle, all these three ratios were higher at a TE of 90 msec. SD/N ratio and SI of fat were higher at a TE of 134 msec. Overall image quality was better at a TE of 134 msec than at one of 90msec. A HASTE sequence with a TE of 134msec showed greater tissue contrast and stronger T2-weighted images than one with a TE of 90msec

  1. Focal adhesive arachnoiditis of the spinal cord: Imaging diagnosis and surgical resolution

    Directory of Open Access Journals (Sweden)

    Hiroki Morisako

    2010-01-01

    Full Text Available Background: Although adhesive arachnoiditis of the spinal cord can cause progressive symptoms associated with syringomyelia or myelomalacia, its surgical resolution based on the imaging diagnosis is not well characterized. This study aims to describe the use of imaging for the diagnosis of focal adhesive arachnoiditis of the spinal cord and its surgical resolution using microsurgical arachnoidolysis. Materials and Methods: Four consecutive patients with symptomatic syringomyelia or myelomalacia caused by focal adhesive arachnoiditis underwent microsurgical arachnoidolysis. Comprehensive imaging evaluation using constructive interference in steady-state (CISS magnetic resonance imaging (MRI or myelographic MR imaging using true fast imaging with steady-state precession (TrueFISP sequences was included before surgery to determine the surgical indication. Results: In all four patients a focal adhesion was identified at the cervical or thoracic level of the spinal cord, a consequence of infection or trauma. Three patients showed modest or minor improvement in neurological function, and one patient was unchanged after surgery. The syringomyelia or myelomalacia resolved after surgery and no recurrence was noted within the follow-up period, which ranged from 5 months to 30 months. Conclusions: MRI diagnosis of focal adhesive arachnoiditis is critical to determine the surgical indication. Microsurgical arachnoidolysis appears to be a straightforward method for stabilizing the progressive symptoms, though the procedure is technically demanding.

  2. Consecutive case series of 244 age-related macular degeneration patients undergoing implantation with an extended macular vision IOL.

    Science.gov (United States)

    Qureshi, Muhammad A; Robbie, Scott J; Hengerer, Fritz H; Auffarth, Gerd U; Conrad-Hengerer, Ina; Artal, Pablo

    2018-03-01

    To determine safety and visual outcomes in eyes with age-related macular degeneration (AMD) implanted with a novel intraocular lens (IOL) that delivers an optimized retinal image to all macular areas within 10 degrees of retinal eccentricity. This was a consecutive case series of 244 eyes with dry/stable wet AMD and logMAR visual acuity ≥0.3 implanted with iolAMD Eyemax mono TM (London Eye Hospital Pharma), a single-piece, injectable, hydrophobic acrylic IOL sited in the capsular bag. Primary outcome was safety. Secondary outcomes were changes in corrected distance visual acuity (CDVA) and corrected near visual acuity (CNVA) (logMAR). Mean age at surgery was 80 years. Mean duration of follow-up was 3 months (range 1-16 months). No eyes had worsening of CDVA. Frequency of perioperative complications was equivalent to standard IOL implantation. Postoperative refractive outcomes were within ±1 D of the target refraction in 88% of cases. Mean preoperative CDVA improved from 1.06 to 0.71 postoperatively (mean of differences -0.35; 95% confidence interval [CI] -0.3886 to -0.3223; p<0.0001), equating to an approximate Early Treatment Diabetic Retinopathy Study gain of 18 letters. Mean preoperative CNVA (N-point; logMAR conversion) improved from 1.36 to 0.88 postoperatively (mean of differences -0.48; 95% CI -0.53 to -0.44; p<0.0001). This novel IOL appears safe in the short to medium term. Improvements in postoperative CDVA and CNVA exceed those observed with standard implants.

  3. Analysis of dental arch relationships in Swedish unilateral cleft lip and palate subjects: 20-year longitudinal consecutive series treated with delayed hard palate closure.

    Science.gov (United States)

    Lilja, Jan; Mars, Michael; Elander, Anna; Enocson, Lars; Hagberg, Catharina; Worrell, Emma; Batra, Puneet; Friede, Hans

    2006-09-01

    To evaluate the dental arch relationships for a consecutive series from Goteborg, Sweden, who had delayed hard palate closure. Retrospective study. Sahlgrenska University Hospital, Goteborg, Sweden. The dental study models of 104 consecutive unilateral cleft lip and palate subjects. The study cohort was born between 1979 and 1994. Longitudinal records were available at ages 5 (n = 94), 10 (n = 97), 16 (n = 59), and 19 years (n = 46). Five assessors rated models according to the GOSLON Yardstick on two separate occasions each. These patients had been operated upon according to the Goteborg protocol of delayed hard palate closure (at age 8 years). 85% of subjects were rated in groups 1 and 2 (excellent or very good outcome), 12% were rated in group 3 (satisfactory), and 3% were assigned to group 4 (poor). No patients presented in Group 5 (very poor). Weighted kappa statistics for double determination of Yardstick allocation for five assessors demonstrated values between .65 and .90 for interrater agreement (good/very good) and between .70 and .90 for intrarater agreement (very good). Delayed hard palate closure as practiced in Goteborg since 1979 has produced the best GOSLON Yardstick ratings in a consecutive series of patients ever recorded worldwide, since the Yardstick was first used in 1983. However, it is noteworthy that a new protocol has been introduced in Goteborg since 1994, in which hard palate closure is done at 3 years due to concerns regarding speech.

  4. Nasopharyngeal cystic lesions: Tornwaldt and mucous retention cysts of the nasopharynx: findings on MR imaging.

    Science.gov (United States)

    Sekiya, Kotaro; Watanabe, Memi; Nadgir, Rohini N; Buch, Karen; Flower, Elisa N; Kaneda, Takashi; Sakai, Osamu

    2014-01-01

    Nasopharyngeal cystic lesions are commonly encountered on magnetic resonance imaging with significantly overlapped imaging characteristics. The purpose of this study was to determine the prevalence and distinguishing imaging features of cystic lesions in the nasopharynx in the largest patient series to date. After institutional review board approval, consecutive head magnetic resonance images of 3000 patients performed at 1.5 T between June 2010 and April 2011 were retrospectively reviewed for cystic nasopharyngeal lesions. Location, size, and signal characteristic of cystic lesions were recorded. Electronic medical records were reviewed for patient demographics, symptoms, and underlying conditions. Among 3000 patients, 6% had Tornwaldt cysts (peak prevalence, 51-60 years old) and 10% had mucous retention cysts (peak prevalence, 41-50 years old). A significant correlation between human immunodeficiency virus infection and mucous retention cysts was observed (P cysts was slightly higher than previously described in the literature. Additionally, younger and older patients had the lowest prevalence of Tornwaldt cyst, suggesting these lesions are acquired and subsequently involute with time. A significant correlation was observed between human immunodeficiency virus infection and mucous retention cysts.

  5. Early detection of tumor relapse/regrowth by consecutive minimal residual disease monitoring in high-risk neuroblastoma patients

    Science.gov (United States)

    Hirase, Satoshi; Saitoh, Atsuro; Hartomo, Tri Budi; Kozaki, Aiko; Yanai, Tomoko; Hasegawa, Daiichiro; Kawasaki, Keiichiro; Kosaka, Yoshiyuki; Matsuo, Masafumi; Yamamoto, Nobuyuki; Mori, Takeshi; Hayakawa, Akira; Iijima, Kazumoto; Nishio, Hisahide; Nishimura, Noriyuki

    2016-01-01

    Neuroblastoma is an aggressive pediatric tumor accounting for ~15% of cancer-associated mortalities in children. Despite the current intensive therapy, >50% of high-risk patients experience tumor relapse or regrowth caused by the activation of minimal residual disease (MRD). Although several MRD detection protocols using various reverse transcription-quantitative polymerase chain reaction (RT-qPCR) markers have been reported to evaluate the therapeutic response and disease status of neuroblastoma patients, their clinical significance remains elusive. The present study reports two high-risk neuroblastoma patients, whose MRD was consecutively monitored using 11 RT-qPCR markers (CHRNA3, CRMP1, DBH, DCX, DDC, GABRB3, GAP43, ISL1, KIF1A, PHOX2B and TH) during their course of treatment. The two patients initially responded to the induction therapy and reached MRD-negative status. The patients' MRD subsequently became positive with no elevation of their urinary homovanillic acid, urinary vanillylmandelic acid and serum neuron-specific enolase levels at 13 or 19 weeks prior to the clinical diagnosis of tumor relapse or regrowth. The present cases highlight the possibility of consecutive MRD monitoring using 11 markers to enable an early detection of tumor relapse or regrowth in high-risk neuroblastoma patients. PMID:27446404

  6. Camera Trajectory fromWide Baseline Images

    Science.gov (United States)

    Havlena, M.; Torii, A.; Pajdla, T.

    2008-09-01

    Camera trajectory estimation, which is closely related to the structure from motion computation, is one of the fundamental tasks in computer vision. Reliable camera trajectory estimation plays an important role in 3D reconstruction, self localization, and object recognition. There are essential issues for a reliable camera trajectory estimation, for instance, choice of the camera and its geometric projection model, camera calibration, image feature detection and description, and robust 3D structure computation. Most of approaches rely on classical perspective cameras because of the simplicity of their projection models and ease of their calibration. However, classical perspective cameras offer only a limited field of view, and thus occlusions and sharp camera turns may cause that consecutive frames look completely different when the baseline becomes longer. This makes the image feature matching very difficult (or impossible) and the camera trajectory estimation fails under such conditions. These problems can be avoided if omnidirectional cameras, e.g. a fish-eye lens convertor, are used. The hardware which we are using in practice is a combination of Nikon FC-E9 mounted via a mechanical adaptor onto a Kyocera Finecam M410R digital camera. Nikon FC-E9 is a megapixel omnidirectional addon convertor with 180° view angle which provides images of photographic quality. Kyocera Finecam M410R delivers 2272×1704 images at 3 frames per second. The resulting combination yields a circular view of diameter 1600 pixels in the image. Since consecutive frames of the omnidirectional camera often share a common region in 3D space, the image feature matching is often feasible. On the other hand, the calibration of these cameras is non-trivial and is crucial for the accuracy of the resulting 3D reconstruction. We calibrate omnidirectional cameras off-line using the state-of-the-art technique and Mičušík's two-parameter model, that links the radius of the image point r to the

  7. Comparison between FLAIR images and T2-weighted fast spin-echo images of cerebral territory and lacunar infarction

    International Nuclear Information System (INIS)

    Paeng, Mi Hye; Choi, Hye-Young; Lim, Soo Mee; Lee, Jung Sik

    2003-01-01

    To assess the significance of fluid-attenuated inversion recovery (FLAIR) magnetic resonance (MR) imaging in the diagnosis of intracranial infarctions and to find out differential points between central lacunar infarctions and perivascular spaces. We consecutively selected 25 cases of territorial infarction in 20 patients, 37 cases of central infarction in 40 patients, and 30 patients with perivascular space. Signal intensity and lesion conspicuity were analyzed and compared between FLAIR and FSE T2-weighted images, and differences in signal intensity between central infarction and perivascular spaces were determined. Lesion conspicuity for FLAIR was better than for T2-weighted images in 12 and 15, worse in 4 and 24, and similar in 9 and 16 of territorial and central infarctions, respectively. In nine cases of territorial and one case of central infarction, there was associated hemorrhage. At FLAIR imaging, perivascular spaces showed a fine round low signal without a peripheral high signal rim in 17 patients but no demonstrable signals in 15. Differential diagnosis of perivascular spaces and central infarction was thus not difficult. FLAIR MRI was useful in the diagnosis of infarctions and in differentiating between central small lacular infarctions and perivascular spaces

  8. Dual-source computed tomography in patients with acute chest pain: feasibility and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Schertler, Thomas; Scheffel, Hans; Frauenfelder, Thomas; Desbiolles, Lotus; Leschka, Sebastian; Stolzmann, Paul; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Department of Medical Radiology, Institute of Diagnostic Radiology, Zurich (Switzerland); Seifert, Burkhardt [University of Zurich, Department of Biostatistics, Zurich (Switzerland); Flohr, Thomas G. [Computed Tomography CTE PA, Siemens Medical Solutions, Forchheim (Germany)

    2007-12-15

    The aim of this study was to determine the feasibility and image quality of dual-source computed tomography angiography (DSCTA) in patients with acute chest pain for the assessment of the lung, thoracic aorta, and for pulmonary and coronary arteries. Sixty consecutive patients (32 female, 28 male, mean age 58.1{+-}16.3 years) with acute chest pain underwent contrast-enhanced electrocardiography-gated DSCTA without prior beta-blocker administration. Vessel attenuation of different thoracic vascular territories was measured, and image quality was semi-quantitatively analyzed by two independent readers. Image quality of the thoracic aorta was diagnostic in all 60 patients, image quality of pulmonary arteries was diagnostic in 59, and image quality of coronary arteries was diagnostic in 58 patients. Pairwise intraindividual comparisons of attenuation values were small and ranged between 1{+-}6 HU comparing right and left coronary artery and 56{+-}9 HU comparing the pulmonary trunk and left ventricle. Mean attenuation was 291{+-}65 HU in the ascending aorta, 334{+-}93 HU in the pulmonary trunk, and 285{+-}66 HU and 268{+-}67 HU in the right and left coronary artery, respectively. DSCTA is feasible and provides diagnostic image quality of the thoracic aorta, pulmonary and coronary arteries in patients with acute chest pain. (orig.)

  9. Dual-source computed tomography in patients with acute chest pain: feasibility and image quality

    International Nuclear Information System (INIS)

    Schertler, Thomas; Scheffel, Hans; Frauenfelder, Thomas; Desbiolles, Lotus; Leschka, Sebastian; Stolzmann, Paul; Marincek, Borut; Alkadhi, Hatem; Seifert, Burkhardt; Flohr, Thomas G.

    2007-01-01

    The aim of this study was to determine the feasibility and image quality of dual-source computed tomography angiography (DSCTA) in patients with acute chest pain for the assessment of the lung, thoracic aorta, and for pulmonary and coronary arteries. Sixty consecutive patients (32 female, 28 male, mean age 58.1±16.3 years) with acute chest pain underwent contrast-enhanced electrocardiography-gated DSCTA without prior beta-blocker administration. Vessel attenuation of different thoracic vascular territories was measured, and image quality was semi-quantitatively analyzed by two independent readers. Image quality of the thoracic aorta was diagnostic in all 60 patients, image quality of pulmonary arteries was diagnostic in 59, and image quality of coronary arteries was diagnostic in 58 patients. Pairwise intraindividual comparisons of attenuation values were small and ranged between 1±6 HU comparing right and left coronary artery and 56±9 HU comparing the pulmonary trunk and left ventricle. Mean attenuation was 291±65 HU in the ascending aorta, 334±93 HU in the pulmonary trunk, and 285±66 HU and 268±67 HU in the right and left coronary artery, respectively. DSCTA is feasible and provides diagnostic image quality of the thoracic aorta, pulmonary and coronary arteries in patients with acute chest pain. (orig.)

  10. Predicting plant biomass accumulation from image-derived parameters

    Science.gov (United States)

    Chen, Dijun; Shi, Rongli; Pape, Jean-Michel; Neumann, Kerstin; Graner, Andreas; Chen, Ming; Klukas, Christian

    2018-01-01

    Abstract Background Image-based high-throughput phenotyping technologies have been rapidly developed in plant science recently, and they provide a great potential to gain more valuable information than traditionally destructive methods. Predicting plant biomass is regarded as a key purpose for plant breeders and ecologists. However, it is a great challenge to find a predictive biomass model across experiments. Results In the present study, we constructed 4 predictive models to examine the quantitative relationship between image-based features and plant biomass accumulation. Our methodology has been applied to 3 consecutive barley (Hordeum vulgare) experiments with control and stress treatments. The results proved that plant biomass can be accurately predicted from image-based parameters using a random forest model. The high prediction accuracy based on this model will contribute to relieving the phenotyping bottleneck in biomass measurement in breeding applications. The prediction performance is still relatively high across experiments under similar conditions. The relative contribution of individual features for predicting biomass was further quantified, revealing new insights into the phenotypic determinants of the plant biomass outcome. Furthermore, methods could also be used to determine the most important image-based features related to plant biomass accumulation, which would be promising for subsequent genetic mapping to uncover the genetic basis of biomass. Conclusions We have developed quantitative models to accurately predict plant biomass accumulation from image data. We anticipate that the analysis results will be useful to advance our views of the phenotypic determinants of plant biomass outcome, and the statistical methods can be broadly used for other plant species. PMID:29346559

  11. Ultrasonography and magnetic resonance imaging in the diagnosis of Morton's neuroma.

    Science.gov (United States)

    Fazal, Muhammad Ali; Khan, Ishrat; Thomas, Cherian

    2012-01-01

    Magnetic resonance imaging (MRI) and ultrasonography are used widely for the diagnosis of Morton's neuroma. The aim of this study was to assess the accuracy of these two modalities as diagnostic tools in Morton's neuroma. Fifty feet of 47 consecutive patients (39 women and 8 men; mean age, 46 years; age range, 36-64 years) who presented between January 1, 2005, and June 30, 2008, were included in the study. Twenty-five feet were investigated with ultrasonography and 25 with MRI. Morton's neuroma was confirmed surgically and histologically in all of the patients. A Student unpaired t test was applied. Twenty-two MRIs were diagnostic (sensitivity, 88%). Three patients with negative MRI findings underwent ultrasonography and were found to have a neuroma smaller than 5 mm. Twenty-four ultrasound scans demonstrated the neuroma (sensitivity, 96%), with five neuromas being smaller than 5 mm. Ultrasonography has a slightly higher sensitivity in the diagnosis of Morton's neuroma, particularly of neuromas smaller than 5 mm, and should be the preferred imaging modality in suspected cases, and MRI should be reserved for cases with equivocal diagnosis.

  12. Intraoperative magnetic resonance imaging-assisted transsphenoidal pituitary surgery in patients with acromegaly.

    Science.gov (United States)

    Bellut, David; Hlavica, Martin; Schmid, Christoph; Bernays, René L

    2010-10-01

    Acromegaly is a rare disease, usually caused by a growth hormone (GH)-producing pituitary adenoma. If untreated, severe cardiovascular, metabolic, cosmetic, and orthopedic disturbances will result. Surgery is generally recommended as the first-line treatment. Transsphenoidal surgical techniques were recently extended by the introduction of intraoperative MR (iMR) imaging. In the present study, the contribution of ultra-low-field (0.15-T) iMR imaging to tumor resection, complication avoidance, and endocrinological and neurological outcome was analyzed. A series of 39 consecutive transsphenoidal iMR imaging-guided (using the PoleStar N20 device) surgical procedures performed between September 2005 and August 2009 for GH-producing pituitary adenomas was retrospectively analyzed. In addition to the patients' clinical data, the following criteria were evaluated independently: duration of surgery; length of hospital stay; endocrinological parameters; results of neurological examinations; and pre-, post-, and intraoperative MR imaging results. Thirty-seven patients with acromegaly underwent 39 transsphenoidal surgeries for pituitary adenomas. During a median follow-up period of 30 months (range 9-56 months), the remission rate was 73.5% in 34 patients with primary surgery and 20% in 5 cases with previous surgery; overall the remission rate was 66.7%. There were no serious postoperative complications. Detection of tumor remnant on iMR imaging led to a 5.1% increase in remission rate. In this largest study to date of GH-producing pituitary adenomas in which iMR imaging-guided transsphenoidal surgery was analyzed, the results suggest that this method is a highly effective and safe treatment modality, even compared with previously published surgical series in which high-field iMR imaging was used. Limitations of iMR imaging are the detection of small residual tumor in the cavernous sinus and persisting disease that could not be observed, even on diagnostic high-field follow

  13. Feasibility study of CT perfusion imaging for prostate carcinoma

    International Nuclear Information System (INIS)

    Cullu, Nesat; Kantarci, Mecit; Ogul, Hayri; Pirimoglu, Berhan; Karaca, Leyla; Kizrak, Yesim; Adanur, Senol; Koc, Erdem; Polat, Ozkan; Okur, Aylin

    2014-01-01

    The aim of this feasibility study was to obtain initial data with which to assess the efficiency of perfusion CT imaging (CTpI) and to compare this with magnetic resonance imaging (MRI) in the diagnosis of prostate carcinoma. This prospective study involved 25 patients with prostate carcinoma undergoing MRI and CTpI. All analyses were performed on T2-weighted images (T2WI), apparent diffusion coefficient (ADC) maps, diffusion-weighted images (DWI) and CTp images. We compared the performance of T2WI combined with DWI and CTp alone. The study was approved by the local ethics committee, and written informed consent was obtained from all patients. Tumours were present in 87 areas according to the histopathological results. The diagnostic performance of the T2WI+DWI+CTpI combination was significantly better than that of T2WI alone for prostate carcinoma (P < 0.001). The diagnostic value of CTpI was similar to that of T2WI+DWI in combination. There were statistically significant differences in the blood flow and permeability surface values between prostate carcinoma and background prostate on CTp images. CTp may be a valuable tool for detecting prostate carcinoma and may be preferred in cases where MRI is contraindicated. If this technique is combined with T2WI and DWI, its diagnostic value is enhanced. (orig.)

  14. Image transmission studies

    International Nuclear Information System (INIS)

    Blaine, G.J.; Hill, R.L.; Rueter, A.P.; Senol, E.; Studt, J.W.

    1988-01-01

    This paper discusses radiological PACS image sizes and desired retrieval response time that demand high-bandwidth communication networks. Local area network technology at speeds higher that 10 Megabits/second (IEEE 802.3) have not achieved standardization nor production volume. The authors describe current PACS experiments based on a three-level subnet approach using 10 Mb/s Ethernet channels. An Ethernet channel is shown to support image transfers at an average throughput of 3 Mb/s. Preliminary measurements and simulation results suggest that traffic from as many as two-to-three archives can be supported on the same channel

  15. Magnetic resonance imaging of the normal placenta

    International Nuclear Information System (INIS)

    Blaicher, Wibke; Brugger, Peter C.; Mittermayer, Christoph; Schwindt, Jens; Deutinger, Josef; Bernaschek, Gerhard; Prayer, Daniela

    2006-01-01

    The goal of this study was to provide a representative description of the normal placenta with contrast medium-free magnetic resonance imaging (MRI) in order to determine a standard of reference. One hundred consecutive singleton pregnancies were investigated by MRI without application of a contrast medium. The mean gestational age (GA) at the time of investigation was 29.5 weeks (range 19-40). Patients with suspected utero-placental insufficiency (UPI) or placental anomalies were excluded. Signal intensities were assessed and correlated with the respective GA. Antenatal MRI without contrast medium was able to depict placental status and morphological changes during gestation. A regular homogeneous structure was found in weeks 19-23. Subsequently, sporadic, slightly marked lobules appeared, which increased in number and markedness with ongoing gestation. Stratification of the lobules was observed after 36 weeks. The ratio of placental and amniotic fluid signal intensities decreased significantly with higher GA and with placental grading. MRI is well suited as an imaging method for the placenta. Our data may be used as a reference in the assessment of the placenta on MRI, and may have further clinical impact with respect to the determination of UPI

  16. Magnetic resonance imaging of the normal placenta

    Energy Technology Data Exchange (ETDEWEB)

    Blaicher, Wibke [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria)]. E-mail: wibke.blaicher@meduniwien.ac.at; Brugger, Peter C. [Center of Anatomy and Cell Biology, University Hospital of Vienna (Austria); Mittermayer, Christoph [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Schwindt, Jens [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Deutinger, Josef [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Bernaschek, Gerhard [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Prayer, Daniela [Department of Radiology, Division of Neuroradiology, University Hospital of Vienna (Austria)

    2006-02-15

    The goal of this study was to provide a representative description of the normal placenta with contrast medium-free magnetic resonance imaging (MRI) in order to determine a standard of reference. One hundred consecutive singleton pregnancies were investigated by MRI without application of a contrast medium. The mean gestational age (GA) at the time of investigation was 29.5 weeks (range 19-40). Patients with suspected utero-placental insufficiency (UPI) or placental anomalies were excluded. Signal intensities were assessed and correlated with the respective GA. Antenatal MRI without contrast medium was able to depict placental status and morphological changes during gestation. A regular homogeneous structure was found in weeks 19-23. Subsequently, sporadic, slightly marked lobules appeared, which increased in number and markedness with ongoing gestation. Stratification of the lobules was observed after 36 weeks. The ratio of placental and amniotic fluid signal intensities decreased significantly with higher GA and with placental grading. MRI is well suited as an imaging method for the placenta. Our data may be used as a reference in the assessment of the placenta on MRI, and may have further clinical impact with respect to the determination of UPI.

  17. Diagnostic accuracy of 64-slice multidetector CT for detection of in-stent restenosis in an unselected, consecutive patient population

    Energy Technology Data Exchange (ETDEWEB)

    Haraldsdottir, Sigurdis, E-mail: sigurdisha@gmail.com [Boston Medical Center, 72 East Concord Street (Evans 124), Boston, MA, 02118 (United States); Gudnason, Thorarinn, E-mail: thorgudn@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Sigurdsson, Axel F., E-mail: axelfsig@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gudjonsdottir, Jonina, E-mail: jonina@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Lehman, Sam J., E-mail: slehman@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Eyjolfsson, Kristjan, E-mail: kristey@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Scheving, Sigurpall S., E-mail: sigurpal@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gibson, C. Michael, E-mail: mgibson@perfuse.org [Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02115 (United States); Hoffmann, Udo, E-mail: uhoffmann@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Jonsdottir, Birna, E-mail: birna@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Andersen, Karl, E-mail: andersen@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland)

    2010-11-15

    Objectives: To investigate the diagnostic accuracy of 64-slice multidetector computed tomography (64-CT) for detection of in-stent restenosis (ISR) in an unselected, consecutive patient population. Background: Detection of in-stent restenosis by cardiac CT would be a major advance for the evaluation of patients suspected of having ISR. However, the diagnostic accuracy of current generation 64-CT in this context is not fully established. Methods: We conducted a prospective study on patients with stable angina or acute coronary syndrome with no prior history of coronary artery disease. Six months after percutaneous coronary intervention (PCI) with stent placement they underwent a 64-CT scan (Toshiba Multi-Slice Aquilion 64) and consequently a repeat coronary angiography for comparison. Cardiac CT data sets were analyzed for the presence of in-stent restenosis by two independent expert readers blinded to the coronary angiographic data. Results: Ninety-three patients with a total of 140 stents were evaluated. Males comprised 82% of the study group and the mean age was 63 {+-} 10 years. The mean time from PCI to the repeat coronary angiography was 208 {+-} 37 days and the mean time from 64-CT to repeat coronary angiography was 3.7 {+-} 4.9 days. The restenosis rate according to coronary angiography was 26%. Stent diameter, strut thickness, heart rate and body mass index (BMI) significantly affected image quality. The sensitivity, specificity, positive and negative predictive values of 64-CT for detection of in-stent restenosis were 27%, 95%, 67% and 78%, respectively. Conclusions: Current generation, 64-slice CT, remains limited in its ability to accurately detect in-stent restenosis.

  18. Reliability of standing weight-bearing (0.25T) MR imaging findings and positional changes in the lumbar spine

    DEFF Research Database (Denmark)

    Hansen, Bjarke B; Hansen, Philip; Christensen, Anders F

    2018-01-01

    OBJECTIVE: To test the reliability and absolute agreement of common degenerative findings in standing positional magnetic resonance imaging (pMRI). METHODS AND MATERIALS: Low back pain patients with and without sciatica were consecutively enrolled to undergo a supine and standing pMRI. Three...

  19. Nonparameningeal head and neck rhabdomyosarcoma in children and adolescents: Lessons from the consecutive International Society of Pediatric Oncology Malignant Mesenchymal Tumor studies.

    Science.gov (United States)

    Orbach, Daniel; Mosseri, Veronique; Gallego, Soledad; Kelsey, Anna; Devalck, Christine; Brenann, Bernadette; van Noesel, Max M; Bergeron, Christophe; Merks, Johannes H M; Rechnitzer, Catherine; Jenney, Meriel; Minard-Colin, Veronique; Stevens, Michael

    2017-01-01

    This article reports risk factors and long-term outcome in localized nonparameningeal head and neck rhabdomyosarcomas in children and adolescents from a combined dataset from 3 consecutive international trials. Data from 140 children (9.3% of total) prospectively enrolled in the International Society of Pediatric Oncology Malignant Mesenchymal Tumor (SIOP-MMT)-84/89/95 studies were analyzed. Primary site was: superficial face in 46%; oral cavity (21%); neck (19%); and salivary glands (14%). Local control was achieved in 96%, but 49% relapsed (locoregionally 91%). At median follow-up of 10 years, 5-year overall survival (OS) was 74.7% (67.4% to 81.9%) and event-free survival 48.9% (40.6% to 57.2%), although this improved with successive studies. Radiotherapy (RT) as first-line treatment was independently prognostic for event-free survival (relative risk [RR] = 0.4 [range, 0.2-0.7]; p < .01) even if it did not impact OS (RR = 1 [range, 0.5-2]). High rates of locoregional relapse were seen in head and neck rhabdomyosarcoma that should be prevented by more frequent use of RT in this primary. © 2016 Wiley Periodicals, Inc. Head Neck 39: 24-31, 2017. © 2016 Wiley Periodicals, Inc.

  20. MR imaging of the shoulder: Spectrum of abnormalities in 65 patients and correlation with arthrography and surgery

    International Nuclear Information System (INIS)

    Zlatkin, M.B.; Reicher, M.A.; Kellerhouse, L.E.; Resnick, D.; Sartoris, D.J.

    1987-01-01

    MR imaging has previously been used to demonstrate the appearance of the normal shoulder. In this investigation the authors employed MR imaging in 65 consecutive patients with shoulder pain. Subsequent arthrography was performed in 31 patients and surgery in 15. Clinical follow-up was obtained in 35 patients treated conservatively. MR imaging was highly accurate in depicting the spectrum of rotator cuff abnormalities associated with mechanical impingment, including both large and small rotator cuff tears as well as tendinitis. Abnormalities of the capsular mechanisms, osseous tumors, ostenonecrosis, and injuries to the supporting musculature were also well depicted. Considerable potential exists for MR imaging in evaluating shoulder joint disease

  1. Characterization of a sequential pipeline approach to automatic tissue segmentation from brain MR Images

    International Nuclear Information System (INIS)

    Hou, Zujun; Huang, Su

    2008-01-01

    Quantitative analysis of gray matter and white matter in brain magnetic resonance imaging (MRI) is valuable for neuroradiology and clinical practice. Submission of large collections of MRI scans to pipeline processing is increasingly important. We characterized this process and suggest several improvements. To investigate tissue segmentation from brain MR images through a sequential approach, a pipeline that consecutively executes denoising, skull/scalp removal, intensity inhomogeneity correction and intensity-based classification was developed. The denoising phase employs a 3D-extension of the Bayes-Shrink method. The inhomogeneity is corrected by an improvement of the Dawant et al.'s method with automatic generation of reference points. The N3 method has also been evaluated. Subsequently the brain tissue is segmented into cerebrospinal fluid, gray matter and white matter by a generalized Otsu thresholding technique. Intensive comparisons with other sequential or iterative methods have been carried out using simulated and real images. The sequential approach with judicious selection on the algorithm selection in each stage is not only advantageous in speed, but also can attain at least as accurate segmentation as iterative methods under a variety of noise or inhomogeneity levels. A sequential approach to tissue segmentation, which consecutively executes the wavelet shrinkage denoising, scalp/skull removal, inhomogeneity correction and intensity-based classification was developed to automatically segment the brain tissue into CSF, GM and WM from brain MR images. This approach is advantageous in several common applications, compared with other pipeline methods. (orig.)

  2. Study on the usefulness of whole body SPECT coronal image, MIP image in {sup 67}Ga scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Seiji [Kurume Univ., Fukuoka (Japan). Hospital; Ishibashi, Masatoshi; Kurata, Seiji; Morita, Seiichirou; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine; Fukushima, Shigehiro [Kyushu Inst. of Design, Fukuoka (Japan). Graduate School of Auditory and Visual Communication Sciences; Umezaki, Noriyoshi [Daiichi Coll. of Pharmaceutical Sciences, Fukuoka (Japan)

    2002-05-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with {sup 67}Ga-citrate ({sup 67}Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  3. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-15

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with {sup 99m}Tc-MDP, DMSA, and {sup 18}F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, {sup 99m}Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined {sup 99}mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and {sup 18}F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug.

  4. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    International Nuclear Information System (INIS)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-01

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with 99m Tc-MDP, DMSA, and 18 F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, 99m Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined 99 mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and 18 F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug

  5. Evaluating coronary reperfusion during acute myocardial infarction in a canine model by gadolinium-DTPA-enhanced magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Kazuaki; Ishibashi, Yutaka; Shimada, Toshio (Shimane Medical Univ., Izumo (Japan)) (and others)

    1993-05-01

    In previous studies, magnetic resonance imaging (MRI) using contrast agents was found to be useful in distinguishing reperfused infarcts from nonreperfused infarcts. However, there have been only a few detailed studies using consecutive MR images for the assessment of myocardial reperfusion during an acute infarction and also no studies have been performed using a percutaneous transluminal coronary occlusion model (closed chest model). We induced acute myocardial infarction in dogs by occluding and then reperfusing the coronary artery with a balloon catheter. ECG-gated MR images were taken using the spin-echo technique before and after Gd-DTPA injection during both coronary artery occlusion and after reperfusion. We defined the intensity ratio (IR) as the signal intensity at the ischemic area divided by that at the nonischemic area on MR images and compared each image by the IR. Without Gd-DTPA, there was no difference between infarcted and normally perfused myocardium. Infarcted myocardium had a low signal intensity (IR=0.68[+-]0.14) soon after Gd-DTPA injection. This difference diminished with time. After reperfusion the infarcted myocardium had a high signal intensity (IR: 1.76[+-]0.34). We conclude that Gd-DTPA-enhanced MRI can distinguish reperfused from nonreperfused infarcts soon after Gd-DTPA administration. (author).

  6. Evaluating coronary reperfusion during acute myocardial infarction in a canine model by gadolinium-DTPA-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Tanabe, Kazuaki; Ishibashi, Yutaka; Shimada, Toshio

    1993-01-01

    In previous studies, magnetic resonance imaging (MRI) using contrast agents was found to be useful in distinguishing reperfused infarcts from nonreperfused infarcts. However, there have been only a few detailed studies using consecutive MR images for the assessment of myocardial reperfusion during an acute infarction and also no studies have been performed using a percutaneous transluminal coronary occlusion model (closed chest model). We induced acute myocardial infarction in dogs by occluding and then reperfusing the coronary artery with a balloon catheter. ECG-gated MR images were taken using the spin-echo technique before and after Gd-DTPA injection during both coronary artery occlusion and after reperfusion. We defined the intensity ratio (IR) as the signal intensity at the ischemic area divided by that at the nonischemic area on MR images and compared each image by the IR. Without Gd-DTPA, there was no difference between infarcted and normally perfused myocardium. Infarcted myocardium had a low signal intensity (IR=0.68±0.14) soon after Gd-DTPA injection. This difference diminished with time. After reperfusion the infarcted myocardium had a high signal intensity (IR: 1.76±0.34). We conclude that Gd-DTPA-enhanced MRI can distinguish reperfused from nonreperfused infarcts soon after Gd-DTPA administration. (author)

  7. Fluorescence Imaging Study of Transition in Underexpanded Free Jets

    Science.gov (United States)

    Wilkes, Jennifer A.; Danehy, Paul M.; Nowak, Robert J.

    2005-01-01

    Planar laser-induced fluorescence (PLIF) is demonstrated to be a valuable tool for studying the onset of transition to turbulence. For this study, we have used PLIF of nitric oxide (NO) to image underexpanded axisymmetric free jets issuing into a low-pressure chamber through a smooth converging nozzle with a sonic orifice. Flows were studied over a range of Reynolds numbers and nozzle-exit-to-ambient pressure ratios with the aim of empirically determining criteria governing the onset of turbulence. We have developed an image processing technique, involving calculation of the standard deviation of the intensity in PLIF images, in order to aid in the identification of turbulence. We have used the resulting images to identify laminar, transitional and turbulent flow regimes. Jet scaling parameters were used to define a rescaled Reynolds number that incorporates the influence of a varying pressure ratio. An empirical correlation was found between transition length and this rescaled Reynolds number for highly underexpanded jets.

  8. A prospective study on contrast-enhanced magnetic resonance imaging of testicular lesions: distinctive features of Leydig cell tumours

    International Nuclear Information System (INIS)

    Manganaro, Lucia; Vinci, Valeria; Saldari, Matteo; Bernardo, Silvia; Cantisani, Vito; Catalano, Carlo; Pozza, Carlotta; Gianfrilli, Daniele; Pofi, Riccardo; Lenzi, Andrea; Isidori, Andrea M.; Scialpi, Michele

    2015-01-01

    Up to 20 % of incidentally found testicular lesions are benign Leydig cell tumours (LCTs). This study evaluates the role of contrast-enhanced magnetic resonance imaging (MRI) in the identification of LCTs in a large prospective cohort study. We enrolled 44 consecutive patients with at least one solid non-palpable testicular lesion who underwent scrotal MRI. Margins of the lesions, signal intensity and pattern of wash-in and wash-out were analysed by two radiologists. The frequency distribution of malignant and benign MRI features in the different groups was compared by using the chi-squared or Fisher's exact test. Sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy were calculated. The sensitivity of scrotal MRI to diagnose LCTs was 89.47 % with 95.65 % specificity; sensitivity for malignant lesions was 95.65 % with 80.95 % specificity. A markedly hypointense signal on T2-WI, rapid and marked wash-in followed by a prolonged washout were distinctive features significantly associated with LCTs. Malignant lesions were significantly associated with blurred margins, weak hypointense signal on T2-WI,and weak and progressive wash-in. The overall diagnostic accuracy was 93 %. LCTs have distinctive contrast-enhanced MRI features that allow the differential diagnosis of incidental testicular lesions. (orig.)

  9. A prospective study on contrast-enhanced magnetic resonance imaging of testicular lesions: distinctive features of Leydig cell tumours

    Energy Technology Data Exchange (ETDEWEB)

    Manganaro, Lucia; Vinci, Valeria; Saldari, Matteo; Bernardo, Silvia; Cantisani, Vito; Catalano, Carlo [Sapienza University of Rome, Department of Radiology, Rome (Italy); Pozza, Carlotta; Gianfrilli, Daniele; Pofi, Riccardo; Lenzi, Andrea; Isidori, Andrea M. [Sapienza University of Rome, Department of Experimental Medicine, Rome (Italy); Scialpi, Michele [Perugia University, S. Maria della Misericordia Hospital, Department of Surgical and Biomedical Sciences, Division of Radiology 2, Perugia (Italy)

    2015-12-15

    Up to 20 % of incidentally found testicular lesions are benign Leydig cell tumours (LCTs). This study evaluates the role of contrast-enhanced magnetic resonance imaging (MRI) in the identification of LCTs in a large prospective cohort study. We enrolled 44 consecutive patients with at least one solid non-palpable testicular lesion who underwent scrotal MRI. Margins of the lesions, signal intensity and pattern of wash-in and wash-out were analysed by two radiologists. The frequency distribution of malignant and benign MRI features in the different groups was compared by using the chi-squared or Fisher's exact test. Sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy were calculated. The sensitivity of scrotal MRI to diagnose LCTs was 89.47 % with 95.65 % specificity; sensitivity for malignant lesions was 95.65 % with 80.95 % specificity. A markedly hypointense signal on T2-WI, rapid and marked wash-in followed by a prolonged washout were distinctive features significantly associated with LCTs. Malignant lesions were significantly associated with blurred margins, weak hypointense signal on T2-WI,and weak and progressive wash-in. The overall diagnostic accuracy was 93 %. LCTs have distinctive contrast-enhanced MRI features that allow the differential diagnosis of incidental testicular lesions. (orig.)

  10. What Images Reveal: a Comparative Study of Science Images between Australian and Taiwanese Junior High School Textbooks

    Science.gov (United States)

    Ge, Yun-Ping; Unsworth, Len; Wang, Kuo-Hua; Chang, Huey-Por

    2017-07-01

    From a social semiotic perspective, image designs in science textbooks are inevitably influenced by the sociocultural context in which the books are produced. The learning environments of Australia and Taiwan vary greatly. Drawing on social semiotics and cognitive science, this study compares classificational images in Australian and Taiwanese junior high school science textbooks. Classificational images are important kinds of images, which can represent taxonomic relations among objects as reported by Kress and van Leeuwen (Reading images: the grammar of visual design, 2006). An analysis of the images from sample chapters in Australian and Taiwanese high school science textbooks showed that the majority of the Taiwanese images are covert taxonomies, which represent hierarchical relations implicitly. In contrast, Australian classificational images included diversified designs, but particularly types with a tree structure which depicted overt taxonomies, explicitly representing hierarchical super-ordinate and subordinate relations. Many of the Taiwanese images are reminiscent of the specimen images in eighteenth century science texts representing "what truly is", while more Australian images emphasize structural objectivity. Moreover, Australian images support cognitive functions which facilitate reading comprehension. The relationships between image designs and learning environments are discussed and implications for textbook research and design are addressed.

  11. Study of scattering in bi-dimensional neutron radiographic images

    International Nuclear Information System (INIS)

    Oliveira, K.A.M. de; Crispim, V.R.; Silva, F.C.

    2009-01-01

    The effect of neutron scattering frequently causes distortions in neutron radiographic images and, thus, reduces the quality. In this project, a type of filter, comprised of cadmium (a neutron absorber), was used in the form of a grid to correct this effect. This device generated image data in the discrete shadow bands of the absorber, components relative to neutron scattering on the test object and surroundings. Scattering image data processing, together with the original neutron radiographic image, resulted in a corrected image with improved edge delineation and, thus, greater definition in the neutron radiographic image of the test object. The objective of this study is to propose a theoretical/experimental methodology that is capable of eliminating the components relative to neutron scattering in neutron radiographic images, coming from the material that composes the test object and the materials that compose the surrounding area. (author)

  12. Comparison of single and consecutive dual frequency induction surface hardening of gear wheels

    Science.gov (United States)

    Barglik, J.; Ducki, K.; Kukla, D.; Mizera, J.; Mrówka-Nowotnik, G.; Sieniawski, J.; Smalcerz, A.

    2018-05-01

    Mathematical modelling of single and consecutive dual - frequency induction surface hardening systems are presented and compared. The both models are solved by the 3D FEM-based professional software supported by a number of own numerical procedures. The methodology is illustrated with some examples of surface induction hardening of a gear wheel made of steel 41Cr4. The computations are in a good accordance with experiments provided on the laboratory stand.

  13. Novel axolotl cardiac function analysis method using magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Pedro Gomes Sanches

    Full Text Available The salamander axolotl is capable of complete regeneration of amputated heart tissue. However, non-invasive imaging tools for assessing its cardiac function were so far not employed. In this study, cardiac magnetic resonance imaging is introduced as a non-invasive technique to image heart function of axolotls. Three axolotls were imaged with magnetic resonance imaging using a retrospectively gated Fast Low Angle Shot cine sequence. Within one scanning session the axolotl heart was imaged three times in all planes, consecutively. Heart rate, ejection fraction, stroke volume and cardiac output were calculated using three techniques: (1 combined long-axis, (2 short-axis series, and (3 ultrasound (control for heart rate only. All values are presented as mean ± standard deviation. Heart rate (beats per minute among different animals was 32.2±6.0 (long axis, 30.4±5.5 (short axis and 32.7±4.9 (ultrasound and statistically similar regardless of the imaging method (p > 0.05. Ejection fraction (% was 59.6±10.8 (long axis and 48.1±11.3 (short axis and it differed significantly (p = 0.019. Stroke volume (μl/beat was 133.7±33.7 (long axis and 93.2±31.2 (short axis, also differed significantly (p = 0.015. Calculations were consistent among the animals and over three repeated measurements. The heart rate varied depending on depth of anaesthesia. We described a new method for defining and imaging the anatomical planes of the axolotl heart and propose one of our techniques (long axis analysis may prove useful in defining cardiac function in regenerating axolotl hearts.

  14. Elimination of motion and pulsation artifacts using BLADE sequences in shoulder MR imaging

    International Nuclear Information System (INIS)

    Lavdas, E.; Zaloni, E.; Vlychou, M.; Vassiou, K.; Fezoulidis, I.; Tsagkalis, A.; Dailiana, Z.

    2015-01-01

    To evaluate the ability of proton-density with fat-suppression BLADE (proprietary name for periodically rotated overlapping parallel lines with enhanced reconstruction in MR systems from Siemens Healthcare, PDFS BLADE) and turbo inversion recovery magnitude-BLADE (TIRM BLADE) sequences to reduce motion and pulsation artifacts in shoulder magnetic resonance examinations. Forty-one consecutive patients who had been routinely scanned for shoulder examination participated in the study. The following pairs of sequences with and without BLADE were compared: (a) Oblique coronal proton-density sequence with fat saturation of 25 patients and (b) oblique sagittal T2 TIRM-weighed sequence of 20 patients. Qualitative analysis was performed by two experienced radiologists. Image motion and pulsation artifacts were also evaluated. In oblique coronal PDFS BLADE sequences, motion artifacts have been significantly eliminated, even in five cases of non-diagnostic value with conventional imaging. Similarly, in oblique sagittal T2 TIRM BLADE sequences, image quality has been improved, even in six cases of non-diagnostic value with conventional imaging. Furthermore, flow artifacts have been improved in more than 80% of all the cases. The use of BLADE sequences is recommended in shoulder imaging, especially in uncooperative patients because it effectively eliminates motion and pulsation artifacts. (orig.)

  15. An evaluation of magnetic resonance imaging at the Royal North Shore Hospital of Sydney, 1986-1987

    International Nuclear Information System (INIS)

    Sorby, W.A.

    1989-01-01

    The diagnostic accuracy and clinical utility have been evaluated of 2810 consecutive magnetic-resonance-imaging examinations that were performed on a 1.5-T Signa magnetic-resonance-imaging unit at The Royal North Shore Hospital of Sydney between November 1986 and December 1987. The average accuracy of magnetic resonance imaging was 80%, and ranged from 21%-98% in various brain-disease and spinal-disease categories, compared with the average provisional premagnetic-resonance-imaging diagnostic accuracy of 64%, and an average accuracy of computed tomography of 45%. Clinical follow-up at three months after magnetic-resonance-imaging investigation indicated that, as a result of the magnetic-resonance-imaging examination, patient management was altered in 70% of cases, and patient outcome was altered in 62% of cases. 32 refs., 4 tabs

  16. A study on secondary images in panoramic radiograph

    International Nuclear Information System (INIS)

    Cho, Dai Hee; Kim, Han Pyong

    1984-01-01

    This study was performed to observe the secondary images and to analyse the relationships between the primary and secondary images in panoramic radiograph. Using the Morita's Panex-EC panoramic x-ray machine and the human dry skull, the author analysed 17 radiographs which were selected from 65 radiographs of the dry skull that attached the radiopaque materials, and the attached regions of the radiopaque materials were the normal anatomical structures which were important and selected as a region for the evaluation of the secondary images effectively. The results were as follows; 1. The cervical vertebrae showed three images. The midline image was the most distorted and less clear, and bilateral images were slightly superimposed over the posterior border of the mandibular ramus. 2. In mandible, the secondary image of the posterior border of the ramus was superimposed on the opposite ramus region, and this image was elongated from the anterior border of the ramus to the lateral side of the posterior border of the ramus. The secondary image of the condyle was observed on the upper area of the coronoid process, the sigmoid notch and the condyle in opposite side. 3. In maxilla, the posterior region of the hard palate showed the secondary image on the lower part of the nasal cavity and the medial wall of the maxillary sinus. 4. The primary images of the occipital condyle and the mastoid process appeared on the same region, and only the secondary image of the occipital condyle was observed symmetrically on the opposite side with similar shape to the primary one. 5. In the cranial base, the anatomical structures of the midsagittal portions like a inferior border of the frontal sinus, sella turcica, inferior border of the sphenoid sinus and inferior border of the posterior part of the occipital bone showed the similar shape between the primary and secondary images symmetrically. 6. The petrous portion of the temporal bone showed the secondary image of the lateral side of

  17. Personal experience on 71 consecutive patients with acute cholecystitis; Esperienza personale in settantuno pazienti consecutivi con colecistite acuta

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, A.; Romano, L.; Scaglione, M.; Pinto, F. [Azienda Ospedaliera di Rilievo Nazionale A. Cardarelli, Neaples (Italy). Dipt. di Diagnostica per Immagini; Romano, S.; Grassi, R.; Cappabianca, S. [Neaples Seconda Univ., Neaples (Italy). Ist. di Scienze Radiologiche; Del Vecchio, W. [Neaples Univ. Federico 2, Neaples (Italy). Ist. di Radiologia

    2000-02-01

    Acute cholecystitis is one of the most frequent abdominal inflammatory processes. If untreated or misdiagnosed it can result in severe complications such as gallbladder rupture, abscesses, or peritonitis. It was retrospectively reviewed a series of 71 consecutive patients with surgical confirmation of acute cholecystitis and then compared the results of the diagnostic techniques that have been used preoperatively. Over 16 months, 71 consecutive patients (42 women and 29 men; age range: 34-84 years, mean: 58) with acute abdominal pain were operated on for acute cholecystitis at Cardarelli Hospital, Naples. On abdominal plain films, it was retrospectively searched the following signs: densities projected over the gallbladder, linear calcifications in gallbladder walls, gallbladder enlargement, focal gas collections within the gallbladder, and air-fluid levels in the gallbladder wall lumen. On US images it has been looked for: gallbladder wall thickening (>3 mm), intraluminal content in the gallbladder, pericholecystic fluid, US Murphy's sign, and gallbladder distension. On CT images, it has been investigated: gallbladder distensions, wall thickening, intraluminal content, pericholecystic fluid, and inflammatory changes in pericholecystic fat. On plain abdominal films it was found densities projected over the gallbladder (16.9%) and linear calcifications in the gallbladder wall (4.6%). US appears to be the most useful imaging technique in patients with suspected acute cholecystitis, for both screening and final diagnosis. CT plays a limited role in the early assessment of these patients, but can a useful tool in diagnosing acute cholecystitis in patients with questionable physical findings or in investigating related complications. [Italian] La colecistite acuta e' una delle flogosi addominali con riscontro piu' frequente. Presenta complicanze (perforazione, ascesso, peritonite) quando non curata o non diagnosticata. Gli autori conducono l

  18. Magnetic resonance imaging of splenic iron overload

    International Nuclear Information System (INIS)

    Arrive, L.; Thurnher, S.; Hricak, H.; Price, D.C.

    1990-01-01

    The value of magnetic resonance (MR) imaging in assessing iron overload in the spleen was retrospectively investigated in 40 consecutive patients. MR appearance, mesaure of signal intensity and T1-and T2-relaxation times were correlated with the histologically determined level of iron in the spleen in each patient. Histologic examination revealed no iron overload in 19 patients, mild iron overload in seven, moderate iron overload in six, and severe iron overload in eight. All 19 patients with no splenic iron overload and 11 of the other 21 patients with splenic iron overload were correctly identified by MR imaging (sensitivity 52%, specificity 100%, accuracy 75%). Splenic iron overload was diagnosed when a decrease of signal intensity of the spleen compared with those of adipose tissue and renal cortex was demonstrated. MR images demonstrated all eight cases of severe, three of the six cases of moderate, and none of the seven cases of mild iron overload. Only spleens with severe iron overload had a significant mean decrease in signal intensity and T1- and T2-relaxation times. Although specific, MR imaging is poorly sensitive to splenic iron overload. (author). 15 refs.; 5 figs.; 3 tabs

  19. The prevalence of IgG4-related hypophysitis in 170 consecutive patients with hypopituitarism and/or central diabetes insipidus and review of the literature.

    Science.gov (United States)

    Bando, Hironori; Iguchi, Genzo; Fukuoka, Hidenori; Taniguchi, Masaaki; Yamamoto, Masaaki; Matsumoto, Ryusaku; Suda, Kentaro; Nishizawa, Hitoshi; Takahashi, Michiko; Kohmura, Eiji; Takahashi, Yutaka

    2014-02-01

    The prevalence and clinical characteristics of IgG4-related hypophysitis remain unclear due to the limited number of case reports. Therefore, in this study, we screened consecutive outpatients with hypopituitarism and/or diabetes insipidus (DI) to estimate its prevalence. A total of 170 consecutive outpatients with hypopituitarism and/or central DI were screened at Kobe University Hospital for detecting IgG4-related hypophysitis by pituitary magnetic resonance imaging, measuring serum IgG4 concentrations, assessing the involvement of other organs, and carrying out an immunohistochemical analysis to detect IgG4-positive cell infiltration. Among the screened cases, 116 cases were excluded due to diagnosis of other causes such as tumors and congenital abnormalities. Additionally, 22 cases with isolated ACTH deficiency were analyzed and were found not to meet the criteria of IgG4-related hypophysitis. The remaining 32 cases were screened and seven were diagnosed with IgG4-related hypophysitis, of which three cases were diagnosed by analyzing pituitary specimens. IgG4-related hypophysitis was detected in 30% (seven of 23 patients) of hypophysitis cases and 4% of all hypopituitarism/DI cases. The mean age at the onset of IgG4-related hypophysitis was 61.8±8.8 years, and the serum IgG4 concentration was 191.1±78.3 mg/dl (normal values 5-105 mg/dl and values in IgG4-related disease (RD) ≥135 mg/dl). Pituitary gland and/or stalk swelling was observed in six patients, and an empty sella was observed in one patient. Multiple co-existing organ involvement was observed in four of the seven patients prior to the onset of IgG4-related hypophysitis. These data suggest that the prevalence of IgG4-related hypophysitis has been underestimated. We should also consider the possibility of the development of hypopituitarism/DI caused by IgG4-related hypophysitis during the clinical course of other IgG4-RDs.

  20. Evaluation of the two non-consecutive 24-h recall instrument for pan-European food consumption surveys

    NARCIS (Netherlands)

    Crispim, S.P.

    2011-01-01

    Background: The comparability of food consumption data originating from national nutritional surveys in Europe is currently hampered because of different methodologies used. Therefore, experts in the European Food Consumption Survey Method (EFCOSUM) consortium proposed to use two non-consecutive

  1. Quantitative Time-Resolved Fluorescence Imaging of Androgen Receptor and Prostate-Specific Antigen in Prostate Tissue Sections.

    Science.gov (United States)

    Krzyzanowska, Agnieszka; Lippolis, Giuseppe; Helczynski, Leszek; Anand, Aseem; Peltola, Mari; Pettersson, Kim; Lilja, Hans; Bjartell, Anders

    2016-05-01

    Androgen receptor (AR) and prostate-specific antigen (PSA) are expressed in the prostate and are involved in prostate cancer (PCa). The aim of this study was to develop reliable protocols for reproducible quantification of AR and PSA in benign and malignant prostate tissue using time-resolved fluorescence (TRF) imaging techniques. AR and PSA were detected with TRF in tissue microarrays from 91 PCa patients. p63/ alpha-methylacyl-CoA racemase (AMACR) staining on consecutive sections was used to categorize tissue areas as benign or cancerous. Automated image analysis was used to quantify staining intensity. AR intensity was significantly higher in AMACR+ and lower in AMACR- cancer areas as compared with benign epithelium. The PSA intensity was significantly lower in cancer areas, particularly in AMACR- glands. The AR/PSA ratio varied significantly in the AMACR+ tumor cells as compared with benign glands. There was a trend of more rapid disease progression in patients with higher AR/PSA ratios in the AMACR- areas. This study demonstrates the feasibility of developing reproducible protocols for TRF imaging and automated image analysis to study the expression of AR and PSA in benign and malignant prostate. It also highlighted the differences in AR and PSA protein expression within AMACR- and AMACR+ cancer regions. © 2016 The Histochemical Society.

  2. Heterogeneity of triple-negative breast cancer: mammographic, US, and MR imaging features according to androgen receptor expression

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Min Sun; Song, Sung Eun; Kim, Won Hwa; Lee, Su Hyun; Moon, Woo Kyung [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Park, So Yeon; Park, In-Ae [Seoul National University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Han, Wonshik; Noh, Dong-Young [Seoul National University College of Medicine, Department of Surgery, Seoul (Korea, Republic of)

    2014-09-16

    Our aim was to determine whether triple-negative breast cancers (TNBCs) with and without androgen receptor (AR) expression have distinguishing imaging features on mammography, breast ultrasound (US), and magnetic resonance (MR) imaging. AR expression was assessed immunohistochemically in 125 patients with TNBC from a consecutive series of 1,086 operable invasive breast cancers. Two experienced radiologists blinded to clinicopathological findings reviewed all imaging studies in consensus using the BI-RADS lexicon. The imaging and pathological features of 33 AR-positive TNBCs were compared with those of 92 AR-negative TNBCs. The presence of mammographic calcifications with or without a mass (p < 0.001), non-mass enhancement on MR imaging (p < 0.001), and masses with irregular shape or spiculated margins on US (p < 0.001 and p = 0.002) and MR imaging (p = 0.001 and p < 0.001) were significantly associated with AR-positive TNBC. Compared with AR-negative TNBC, AR-positive TNBC was more likely to have a ductal carcinoma in situ component (59.8 % vs. 90.9 %, p = 0.001) and low Ki-67 expression (30.4 % vs. 51.5 %, p = 0.030). AR-positive and AR-negative TNBCs have different imaging features, and certain imaging findings can be useful to predict AR status in TNBC. (orig.)

  3. Establishment of quality assessment standard for mammographic equipment: evaluation of phantom and clinical images

    International Nuclear Information System (INIS)

    Lee, Sung Hoon; Choe, Yeon Hyeon; Chung, Soo Young

    2005-01-01

    The purpose of this study was to establish a quality standard for mammographic equipment Korea and to eventually improve mammographic quality in clinics and hospitals throughout Korea by educating technicians and clinic personnel. For the phantom test and on site assessment, we visited 37 sites and examined 43 sets of mammographic equipment. Items that were examined include phantom test, radiation dose measurement, developer assessment, etc. The phantom images were assessed visually and by optical density measurements. For the clinical image assessment, clinical images from 371 sites were examined following the new Korean standard for clinical image evaluation. The items examined include labeling, positioning, contrast, exposure, artifacts, collimation among others. Quality standard of mammographic equipment was satisfied in all equipment on site visits. Average mean glandular dose was 114.9 mRad. All phantom image test scores were over 10 points (average, 10.8 points). However, optical density measurements were below 1.2 in 9 sets of equipment (20.9%). Clinical image evaluation revealed appropriate image quality in 83.5%, while images from non-radiologist clinics were adequate in 74.6% (91/122), which was the lowest score of any group. Images were satisfactory in 59.0% (219/371) based on evaluation by specialists following the new Korean standard for clinical image evaluation. Satisfactory images had a mean score of 81.7 (1 S.D. =8.9) and unsatisfactory images had a mean score of 61.9 (1 S.D = 11). The correlation coefficient between the two observers was 0.93 (ρ < 0.01) in 49 consecutive cases. The results of the phantom tests suggest that optical density measurements should be performed as part of a new quality standard for mammographic equipment. The new clinical evaluation criteria that was used in this study can be implemented with some modifications for future mammography quality control by the Korean government

  4. Studying depression using imaging and machine learning methods.

    Science.gov (United States)

    Patel, Meenal J; Khalaf, Alexander; Aizenstein, Howard J

    2016-01-01

    Depression is a complex clinical entity that can pose challenges for clinicians regarding both accurate diagnosis and effective timely treatment. These challenges have prompted the development of multiple machine learning methods to help improve the management of this disease. These methods utilize anatomical and physiological data acquired from neuroimaging to create models that can identify depressed patients vs. non-depressed patients and predict treatment outcomes. This article (1) presents a background on depression, imaging, and machine learning methodologies; (2) reviews methodologies of past studies that have used imaging and machine learning to study depression; and (3) suggests directions for future depression-related studies.

  5. Magnetic resonance imaging validation of pituitary gland compression and distortion by typical sellar pathology.

    Science.gov (United States)

    Cho, Charles H; Barkhoudarian, Garni; Hsu, Liangge; Bi, Wenya Linda; Zamani, Amir A; Laws, Edward R

    2013-12-01

    Identification of the normal pituitary gland is an important component of presurgical planning, defining many aspects of the surgical approach and facilitating normal gland preservation. Magnetic resonance imaging is a proven imaging modality for optimal soft-tissue contrast discrimination in the brain. This study is designed to validate the accuracy of localization of the normal pituitary gland with MRI in a cohort of surgical patients with pituitary mass lesions, and to evaluate for correlation between presurgical pituitary hormone values and pituitary gland characteristics on neuroimaging. Fifty-eight consecutive patients with pituitary mass lesions were included in the study. Anterior pituitary hormone levels were measured preoperatively in all patients. Video recordings from the endoscopic or microscopic surgical procedures were available for evaluation in 47 cases. Intraoperative identification of the normal gland was possible in 43 of 58 cases. Retrospective MR images were reviewed in a blinded fashion for the 43 cases, emphasizing the position of the normal gland and the extent of compression and displacement by the lesion. There was excellent agreement between imaging and surgery in 84% of the cases for normal gland localization, and in 70% for compression or noncompression of the normal gland. There was no consistent correlation between preoperative pituitary dysfunction and pituitary gland localization on imaging, gland identification during surgery, or pituitary gland compression. Magnetic resonance imaging proved to be accurate in identifying the normal gland in patients with pituitary mass lesions, and was useful for preoperative surgical planning.

  6. NMR imaging studies of coal

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Z.R.; Zhang, P.Z.; Ding, G.L.; Li, L.Y.; Ye, C.H. [University of Science and Technology, Beijing (China). Dept. of Chemistry

    1996-06-01

    The permeation transportation and swelling behavior of solvents into coal are investigated by NMR imaging using pyridine-d{sub 5} and acetone-d{sub 6}. Images of coal swollen with deuterated solvents illuminate proton distributions of mobile phases within the coal macromolecular networks. More information about the chemical and physical structure of coal can be obtained using NMR imaging techniques.

  7. Very low survival rates after non-traumatic lower limb amputation in a consecutive series

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange; Holm, Gitte; Kirketerp-Møller, Klaus

    2012-01-01

    The aim of this retrospective study was to evaluate factors potentially influencing short- and long-term mortality in patients who had a non-traumatic lower limb amputation in a university hospital. A consecutive series of 93 amputations (16% toe/foot, 33% trans-tibial, 9% through knee and 42......% trans-femoral) were studied. Their mean age was 75.8 years; 21 (23%) were admitted from a nursing home and 87 (92%) were amputated due to a vascular disease and/or diabetes. Thirty days and 1-year mortality were 30 and 54%, respectively. Cox regression analysis demonstrated that the 30-day mortality...... was associated with older age (P = 0.01), and the number of co-morbidities (P = 0.04), when adjusted for gender, previous amputations, cause of and amputation level, and residential status. Thus, a patient with 4 or 5 co-morbidities (n = 20) was seven times more likely to die within 30 days, compared...

  8. Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage.

    Science.gov (United States)

    Bonatti, Matteo; Lombardo, Fabio; Zamboni, Giulia A; Pernter, Patrizia; Pozzi Mucelli, Roberto; Bonatti, Giampietro

    2017-07-01

    To evaluate the diagnostic performance of virtual non-contrast (VNC) images in detecting intracranial haemorrhages (ICHs). Sixty-seven consecutive patients with and 67 without ICH who underwent unenhanced brain CT and DECT angiography were included. Two radiologists independently evaluated VNC and true non-contrast (TNC) images for ICH presence and type. Inter-observer agreement for VNC and TNC image evaluation was calculated. Sensitivity and specificity of VNC images for ICH detection were calculated using Fisher's exact test. VNC and TNC images were compared for ICH extent (qualitatively and quantitatively) and conspicuity assessment. On TNC images 116 different haemorrhages were detected in 67 patients. Inter-observer agreement ranged from 0.98-1.00 for TNC images and from 0.86-1.00 for VNC images. VNC sensitivity ranged from 0.90-1, according to the different ICH types, and specificity from 0.97-1. Qualitatively, ICH extent was underestimated on VNC images in 11.9% of cases. Haemorrhage volume did not show statistically significant differences between VNC and TNC images. Mean haemorrhage conspicuity was significantly lower on VNC images than on TNC images for both readers (p < 0.001). VNC images are accurate for ICH detection. Haemorrhages are less conspicuous on VNC images and their extent may be underestimated. • VNC images represent a reproducible tool for detecting ICH. • ICH can be identified on VNC images with high sensitivity and specificity. • Intracranial haemorrhages are less conspicuous on VNC images than on TNC images. • Intracranial haemorrhages extent may be underestimated on VNC images.

  9. Use of imaging during symptomatic follow-up after resection of pancreatic ductal adenocarcinoma.

    Science.gov (United States)

    Groot, Vincent P; Daamen, Lois A; Hagendoorn, Jeroen; Borel Rinkes, Inne H M; van Santvoort, Hjalmar C; Molenaar, I Quintus

    2018-01-01

    Controversy exists whether follow-up after resection of pancreatic ductal adenocarcinoma (PDAC) should include standardized imaging for the detection of disease recurrence. The purpose of this study was to evaluate how often patients undergo imaging in a setting where routine imaging is not performed. Secondly, the pattern, timing, and treatment of recurrent PDAC were assessed. This was a post hoc analysis of a prospective database of all consecutive patients undergoing pancreatic resection of PDAC between January 2011 and January 2015. Data on imaging procedures during follow-up, recurrence location, and treatment for recurrence were extracted and analyzed. Associations between clinical characteristics and post-recurrence survival were assessed with the log-rank test and Cox univariable and multivariable proportional hazards models. A total of 85 patients were included. Seventy-four patients (87%) underwent imaging procedures during follow-up at least once, with a mean amount of 3.1 ± 1.9 imaging procedures during the entire follow-up period. Sixty-eight patients (80%) were diagnosed with recurrence, 58 (85%) of whom after the manifestation of clinical symptoms. Additional tumor-specific treatment was administered in 17 of 68 patients (25%) with recurrence. Patients with isolated local recurrence, treatment after recurrence, and a recurrence-free survival >10 mo had longer post-recurrence survival. Even though a symptomatic follow-up strategy does not include routine imaging, the majority of patients with resected PDAC underwent additional imaging procedures during their follow-up period. Further prospective studies are needed to determine the actual clinical value, psychosocial implications, and cost-effectiveness of different forms of follow-up after resection of PDAC. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. MR imaging of ossification of the posterior longitudinal ligament in the cervical spine

    Energy Technology Data Exchange (ETDEWEB)

    Yanase, Mitsuhiro; Yone, Kazunori; Taketomi, Eiji; Kawaida, Hidefumi; Sakou, Takashi (Kagoshima Univ. (Japan). Faculty of Medicine)

    1992-09-01

    Magnetic resonance (MR) images from consecutive 100 patients with ossification of the posterior longitudinal ligament (OPLL) were retrospectively reviewed to determine MR manifestations of OPLL foci (ossificated foci) and the surrounding tissue. MR images from 50 patients with cervical spondylosis served as controls for comparison. Inside ossificated foci were isointense or hyperintense on T1-weighted images in 43% of the OPLL cases and on T2-weighted images in 38%. According to X-ray proven ossification form, both T1- and T2-weighted images showed isointensity or hyperintensity in approximately half of the cases of continuous and mixed types of ossificated foci. Two characteristic morphologies of cervical disc were seen more frequently in OPLL than cervical spondylosis, which has clinical implication for continuously proliferated fibrocartilage in the cervical disc. Hypertrophy of the posterior longitudinal ligament was seen in 7% of OPLL cases on MR images, reflecting the likelihood of precursor condition of ossification. (N.K.).

  11. Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Mieville, Frederic A.; Bochud, Francois O.; Verdun, Francis R. [Lausanne University Hospital, Institute of Radiation Physics, Lausanne (Switzerland); Berteloot, Laureline; Brunelle, Francis [Necker Children' s Hospital of Paris and University of Paris Descartes, Department of Pediatric Radiology, Paris (France); Grandjean, Albane; Ayestaran, Paul [General Electric Medical Systems Europe, Paris (France); Gudinchet, Francois; Schmidt, Sabine [Lausanne University Hospital, Department of Radiology, Lausanne (Switzerland)

    2013-03-15

    The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO trademark is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. To evaluate the potential of VEO trademark on diagnostic image quality and dose reduction in pediatric chest CT examinations. Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDI{sub vol} 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection. (orig.)

  12. COMPARATIVE STUDY OF EDGE BASED LSB MATCHING STEGANOGRAPHY FOR COLOR IMAGES

    Directory of Open Access Journals (Sweden)

    A.J. Umbarkar

    2016-02-01

    Full Text Available Steganography is a very pivotal technique mainly used for covert transfer of information over a covert communication channel. This paper proposes a significant comparative study of the spatial LSB domain technique that focuses on sharper edges of the color as well as gray scale images for the purpose of data hiding and hides secret message first in sharper edge regions and then in smooth regions of the image. Message embedding depends on content of the image and message size. The experimental results illustrate that, for low embedding rate the method hides the message in sharp edges of cover image to get better stego image visualization quality. For high embedding rate, smooth regions and edges of the cover image are used for the purpose of data hiding. In this steganography method, color image and textured kind of image preserves better visual quality of stego image. The novelty of the comparative study is that, it helps to analyze the efficiency and performance of the method as it gives better results because it directly works on color images instead of converting to gray scale image.

  13. Comparative study of image restoration techniques in forensic image processing

    Science.gov (United States)

    Bijhold, Jurrien; Kuijper, Arjan; Westhuis, Jaap-Harm

    1997-02-01

    In this work we investigated the forensic applicability of some state-of-the-art image restoration techniques for digitized video-images and photographs: classical Wiener filtering, constrained maximum entropy, and some variants of constrained minimum total variation. Basic concepts and experimental results are discussed. Because all methods appeared to produce different results, a discussion is given of which method is the most suitable, depending on the image objects that are questioned, prior knowledge and type of blur and noise. Constrained minimum total variation methods produced the best results for test images with simulated noise and blur. In cases where images are the most substantial part of the evidence, constrained maximum entropy might be more suitable, because its theoretical basis predicts a restoration result that shows the most likely pixel values, given all the prior knowledge used during restoration.

  14. Software Image J to study soil pore distribution

    Directory of Open Access Journals (Sweden)

    Sabrina Passoni

    2014-04-01

    Full Text Available In the soil science, a direct method that allows the study of soil pore distribution is the bi-dimensional (2D digital image analysis. Such technique provides quantitative results of soil pore shape, number and size. The use of specific softwares for the treatment and processing of images allows a fast and efficient method to quantify the soil porous system. However, due to the high cost of commercial softwares, public ones can be an interesting alternative for soil structure analysis. The objective of this work was to evaluate the quality of data provided by the Image J software (public domain used to characterize the voids of two soils, characterized as Geric Ferralsol and Rhodic Ferralsol, from the southeast region of Brazil. The pore distribution analysis technique from impregnated soil blocks was utilized for this purpose. The 2D image acquisition was carried out by using a CCD camera coupled to a conventional optical microscope. After acquisition and treatment of images, they were processed and analyzed by the software Noesis Visilog 5.4® (chosen as the reference program and ImageJ. The parameters chosen to characterize the soil voids were: shape, number and pore size distribution. For both soils, the results obtained for the image total porosity (%, the total number of pores and the pore size distribution showed that the Image J is a suitable software to be applied in the characterization of the soil sample voids impregnated with resin.

  15. High-resolution MR imaging of glenohumeral instability lesions

    International Nuclear Information System (INIS)

    Rafii, M.; Firooznia, H.; Sherman, O.; Minkoff, J.; Sherman, M.; Golimbu, C.

    1991-01-01

    This paper determines the accuracy of conventual MR imaging in the diagnosis of glenohumeral instabilities and evaluates various pathologic aspects of these lesions. Records were reviewed in 80 consecutive patients with known or suspected instability who underwent MR imaging. The routine shoulder protocol included a proton density- or T2-weighted sequence. Surgical correlation was available in 31 cases. Diagnosis of glenohumeral instability was based on the presence of a combination of findings of appropriately located tear, osseous abnormality of glenoid margin, capsular abnormalities and Hill-Sachs deformity. In 28 surgically correlated patients with glenohumeral instability an accurate diagnosis was made in all but 1 case of posterior instability. A false diagnosis of instability was suggested in 3 cases by signal abnormality of the labrum and/or a prominent capsule

  16. Enterovirus 71-related encephalomyelitis: usual and unusual magnetic resonance imaging findings

    International Nuclear Information System (INIS)

    Jang, Seonah; Suh, Sang-Il; Ha, Su Min; Seol, Hae-Young; Byeon, Jung Hye; Eun, Baik-Lin; Lee, Young Hen; Seo, Hyung Suk; Eun, So-Hee

    2012-01-01

    Most enterovirus (EV) 71 infections manifest as mild cases of hand-foot-mouth disease (HFMD)/herpangina with seasonal variations, having peak incidence during the summer. Meanwhile, EV 71 may involve the central nervous system (CNS), causing severe neurologic disease. In many cases, enteroviral encephalomyelitis involves the central midbrain, posterior portion of the medulla oblongata and pons, bilateral dentate nuclei of the cerebellum, and the ventral roots of the cervical spinal cord, and the lesions show hyperintensity on T2-weighted and fluid-attenuation inversion recovery (FLAIR) images. Our goal was to review usual and unusual magnetic resonance (MR) findings in CNS involvement of enteroviral infection. Among consecutive patients who had HFMD and clinically suspected encephalitis or myelitis and who underwent brain or spinal MR imaging, five patients revealed abnormal MR findings. Diffusion-weighted and conventional MR and follow-up MR images were obtained. From cerebrospinal fluid, stool, or nasopharyngeal swabs, EV 71 was confirmed in all patients. MR imaging studies of two patients showed hyperintensity in the posterior portion of the brainstem on T2-weighted and FLAIR images, which is the well-known MR finding of EV 71 encephalitis. The remaining three cases revealed unusual manifestations: leptomeningeal enhancement, abnormal enhancement along the ventral roots at the conus medullaris level without brain involvement, and hyperintensity in the left hippocampus on T2/FLAIR images. EV 71 encephalomyelitis shows relatively characteristic MR findings; therefore, imaging can be helpful in radiologic diagnosis. However, physicians should also be aware of unusual radiologic manifestations of EV 71. (orig.)

  17. Enterovirus 71-related encephalomyelitis: usual and unusual magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seonah; Suh, Sang-Il; Ha, Su Min; Seol, Hae-Young [Korea University Guro Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Byeon, Jung Hye; Eun, Baik-Lin [Korea University Guro Hospital, Korea University College of Medicine, Department of Pediatrics, Seoul (Korea, Republic of); Lee, Young Hen; Seo, Hyung Suk [Korea University Ansan Hospital, Korea University College of Medicine, Department of Radiology, Ansan (Korea, Republic of); Eun, So-Hee [Korea University Ansan Hospital, Korea University College of Medicine, Department of Pediatrics, Ansan (Korea, Republic of)

    2012-03-15

    Most enterovirus (EV) 71 infections manifest as mild cases of hand-foot-mouth disease (HFMD)/herpangina with seasonal variations, having peak incidence during the summer. Meanwhile, EV 71 may involve the central nervous system (CNS), causing severe neurologic disease. In many cases, enteroviral encephalomyelitis involves the central midbrain, posterior portion of the medulla oblongata and pons, bilateral dentate nuclei of the cerebellum, and the ventral roots of the cervical spinal cord, and the lesions show hyperintensity on T2-weighted and fluid-attenuation inversion recovery (FLAIR) images. Our goal was to review usual and unusual magnetic resonance (MR) findings in CNS involvement of enteroviral infection. Among consecutive patients who had HFMD and clinically suspected encephalitis or myelitis and who underwent brain or spinal MR imaging, five patients revealed abnormal MR findings. Diffusion-weighted and conventional MR and follow-up MR images were obtained. From cerebrospinal fluid, stool, or nasopharyngeal swabs, EV 71 was confirmed in all patients. MR imaging studies of two patients showed hyperintensity in the posterior portion of the brainstem on T2-weighted and FLAIR images, which is the well-known MR finding of EV 71 encephalitis. The remaining three cases revealed unusual manifestations: leptomeningeal enhancement, abnormal enhancement along the ventral roots at the conus medullaris level without brain involvement, and hyperintensity in the left hippocampus on T2/FLAIR images. EV 71 encephalomyelitis shows relatively characteristic MR findings; therefore, imaging can be helpful in radiologic diagnosis. However, physicians should also be aware of unusual radiologic manifestations of EV 71. (orig.)

  18. A study of metal artifacts on MR imaging. Evaluation of scanning parameters

    International Nuclear Information System (INIS)

    Yamashiro, Mitsuaki

    1999-01-01

    The purpose of this study was to evaluate scanning parameters on MR imaging for reducing metal artifacts using phantom study. Metal artifacts on sagittal images, perpendicular to static magnetic direction showed round shape in the relationship between shape of metal artifacts on MR images and scanning direction. Metal artifacts on both axial and coronal images, parallel to static magnetic direction showed oval shape in the direction of X-axis. In spin echo sequences, the largest dimension of metal artifacts was coronal image, followed by axial image and then sagittal image. In gradient echo sequences, the largest dimension of metal artifacts was axial image, followed by coronal image and then sagittal image. The best scanning plane for reducing metal artifacts was perpendicular to static magnetic direction. In scanning sequences, the largest dimensions of metal artifacts were gradient echo sequences, followed by T2-weighted spin echo sequence and then proton density-weighted and T1-weighted spin echo sequences. Large flip angle increased much metal artifacts on both axial and coronal images in gradient echo sequences. Small flip angle was useful for reducing metal artifacts on both axial and coronal images. The influence of flip angle on metal artifacts in sagittal images perpendicular static magnetic direction was less than for images in coronal and axial planes on gradient echo sequences. These results suggested that a study of metal artifacts on MR imaging about evaluation of scanning parameters was useful to reduce metal artifacts on MR images. (K.H.)

  19. Phantom and animal imaging studies using PLS synchrotron X-rays

    CERN Document Server

    Hee Joung Kim; Kyu Ho Lee; Hai Jo Jung; Eun Kyung Kim; Jung Ho Je; In Woo Kim; Yeukuang, Hwu; Wen Li Tsai; Je Kyung Seong; Seung Won Lee; Hyung Sik Yoo

    2001-01-01

    Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ultra-high resolution images for, resolution test patterns, mammograph...

  20. Clinical characteristics of hepatocellular carcinoma patients with normal serum alpha-fetoprotein level: A study of 112 consecutive cases.

    Science.gov (United States)

    Li, Li; Chen, Jinglong; Xu, Weiran; Ding, Xiaosheng; Wang, Xiangyi; Liang, Jun

    2017-10-26

    Serum alpha-fetoprotein (AFP) level is normal in 30-40% of hepatocellular carcinoma (HCC) patients, and knowledge on its characteristics and clinical outcome is limited. The purpose of this observational study was to determine the clinical presentation, biological behavior and outcome of HCC patients with normal AFP level. Data of 112 consecutive HCC patients with normal AFP level were analyzed retrospectively. Statistical analysis including survival and factors associated with serum AFP level were performed by Kaplan-Meier method and t-test, respectively. Hepatitis B virus infection exited in 83.0% of all 112 HCC patients with normal AFP level. During a mean 52 ± 20 months (range 5-85 months) follow-up, the 1-, 2-, 3-year overall survival (OS) rate was 97.2%, 85.3% and 81.7%, respectively. The OS rates at 3 years stratified by stages at diagnosis were 100%, 96.2%, 85.7%, 11.1% and 0%, respectively for Barcelona Clinic Liver Cancer (BCLC) stage 0-D diseases. Significant difference in OS was observed among patients with BCLC stage 0-D diseases, P level elevated beyond normal figure during follow-up (AFP conversion) in 16 patients, which related with deterioration of liver function, quantitative changes of T helper cell subsets, rapid tumor progression and shorter survival. Patients with sustained normal AFP level had better survival than patients with AFP conversion, P level elevation and the time of AFP elevation to death, P level was relatively optimal. Serum AFP level elevation during follow-up was significantly associated with clinical outcome in terms of OS. © 2017 John Wiley & Sons Australia, Ltd.

  1. Resident education in robotic-assisted vertical sleeve gastrectomy: outcomes and cost-analysis of 411 consecutive cases.

    Science.gov (United States)

    Ecker, Brett L; Maduka, Richard; Ramdon, Andre; Dempsey, Daniel T; Dumon, Kristoffel R; Williams, Noel N

    2016-02-01

    Robotic technology is increasingly prevalent in bariatric surgery, yet there are national deficiencies in exposure of surgical residents to robotic techniques. The purpose of this study is to accurately characterize the perioperative outcomes of a resident teaching model using the robotic-assisted sleeve gastrectomy. University Hospital. We identified 411 consecutive patients who underwent robotic sleeve gastrectomy at our institution from a prospectively maintained administrative database. Perioperative morbidity, operative time, and supply cost of the procedure were analyzed. Mean operative time was 96.4±24.9 minutes; mean robot usage time was 63.9 minutes (range 30.0-122.0 min). Ninety-day morbidities included reoperation (0.72%), major bleeding complications (0.48%), staple line leak (0.24%), stricture (0.97%), need for blood transfusion (3.86%), surgical site infection (1.69%), deep vein thrombosis (0.48%), and pulmonary embolism (0.48%). Mortality was nil. The resident cohort achieved operative time plateaus after five consecutive cases. Subset analysis for fiscal year 2014 demonstrated significantly increased supply cost for robotic sleeve gastrectomy compared with its laparoscopic equivalent. Robotic-assisted sleeve gastrectomy can be instituted as a model for resident robotic education with rates of morbidity and operative times equivalent to historical laparoscopic controls. The robot's enhanced ergonomics and its opportunity for resident education must be weighed against its increased supply cost. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  2. Magnetic resonance imaging of avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Thickman, D.; Axel, L.; Kressel, H.Y.; Velchick, M.; Dalinka, M.; Steinberg, M.; Chen, H.; Fallon, M.

    1986-01-01

    This study investigates the role of magnetic resonance imaging (MR) in identifying avascular necrosis (AVN) of the femoral head and in monitoring its therapy. The detection of AVN, particularly in its early stages, is imperative to give therapeutic intervention the best opportunity for successful management. The results of magnetic resonance imaging are compared with those of the standard diagnostic modalities in evaluation of patients with the lesion. Examinations were performed at 0.12 T with a repetition time (TR) of 143 ms and times to echo (TE's) of 10 or 20 ms. This study represents a retrospective review of 90 hips which were examined in 45 consecutive patients. Of these, 52 hips were biopsied as part of treatment. MR was shown to be sensitive in the detection of AVN. Comparison of MR with radionuclide imaging showed comparable sensitivity and specificity. MR was also noted to be sensitive in the detection of early AVN. Preliminary results suggest that MR can monitor treatment of the affected hip, and may even be able to predict patient response to therapy. Although further work is necessary to determine the role of MR in the evaluation of the patient presenting with hip pain, MR is a sensitive method in detecting AVN and in monitoring its course in patients suspected of having the disease. (orig.)

  3. Magnetic resonance imaging of avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Thickman, D; Axel, L; Kressel, H Y; Velchick, M; Dalinka, M; Steinberg, M; Chen, H; Fallon, M

    1986-02-01

    This study investigates the role of magnetic resonance imaging (MR) in identifying avascular necrosis (AVN) of the femoral head and in monitoring its therapy. The detection of AVN, particularly in its early stages, is imperative to give therapeutic intervention the best opportunity for successful management. The results of magnetic resonance imaging are compared with those of the standard diagnostic modalities in evaluation of patients with the lesion. Examinations were performed at 0.12 T with a repetition time (TR) of 143 ms and times to echo (TE's) of 10 or 20 ms. This study represents a retrospective review of 90 hips which were examined in 45 consecutive patients. Of these, 52 hips were biopsied as part of treatment. MR was shown to be sensitive in the detection of AVN. Comparison of MR with radionuclide imaging showed comparable sensitivity and specificity. MR was also noted to be sensitive in the detection of early AVN. Preliminary results suggest that MR can monitor treatment of the affected hip, and may even be able to predict patient response to therapy. Although further work is necessary to determine the role of MR in the evaluation of the patient presenting with hip pain, MR is a sensitive method in detecting AVN and in monitoring its course in patients suspected of having the disease.

  4. Prospective study of bone metastasis from prostate cancer: comparison between large field diffusion-weighted imaging and bone scintigraphy

    International Nuclear Information System (INIS)

    Wang Xiaoying; Zhang Chunyan; Jiang Xuexiang

    2009-01-01

    Objective: To evaluate the large field diffusion weighted imaging (DWI) (from head vertex to lower leg) in detection of bone metastases from prostate cancer. Methods: One hundred and sixty- six consecutive patients who were suspected of prostate cancer received pelvic MRI and large field diffusion weighted imaging examination. Forty-nine of them underwent bone scintigraphy within one month of the examination of large field DWI. The images were double-blindly evaluated without the knowledge of the pathology result. Conventional MR T 1 and fat saturation T 2 weighted images were taken as standard for the diagnosis of bone metastasis. The sensitivity, specificity, and area under curve between large field DWI and bone scintigraphy were compared with McNemar test. Five patients with bone metastases exceeding 10 per patient were excluded in the lesion-by-lesion analysis. Results: Ten of the 49 patients were diagnosed as bone metastases. The diagnosis of bone metastasis were made in 15 patients by large field DWI and in 17 patients by bone scintigraphy. With patient number as study units (n=49), the diagnostic sensitivity of bone metastases with large field DWI and bone metastases were both 100% (10/10), and specificity were 87.2% (34/39) vs. 82.1% (32/39), respectively. ROC study showed the area under curve (AUC) of large field DWI and bone scintigraphy were 0.936 vs. 0.910, respectively. Totally 68 abnormal foci were identified from large field DWI and/or bone scintigraphy in 44 patients (while 5 patients with bone metastases exceeding 10 foci per patient were excluded), 20 of them were diagnosed as foci of bone metastasis. The diagnosis of bone metastases was made in 23 foci by large field DWI and in 34 by bone scintigraphy. With lesion numbers as study units (n=68), the diagnostic sensitivity of large field DWI and bone scintigraphy were both 90.0% (18/20), and specificity were 89.6% (43/48) vs. 66.7% (32/48), respectively. ROC study showed the area under curve of

  5. Pulmonary embolism in pregnancy: is nuclear medicine imaging still a valid option?

    LENUS (Irish Health Repository)

    Ezwawah, O

    2008-10-01

    In this study we demonstrate our Radiology Department\\'s experience in utilizing low dose (half the normal dose) lung perfusion radionuclide scanning for pregnant patients as the initial investigation for suspected pulmonary embolism (PE). Secondly; we highlight the radiation dose reduction advantages of nuclear medicine imaging over multi-detector computed tomography in this group. We performed a retrospective study of 21 consecutive pregnant women who presented with suspected PE. These patients underwent either lung perfusion scanning or CT pulmonary angiography (CTPA), over a two-year period (May 2005 to July 2007). 19 patients of the cohort studied underwent low dose perfusion-only scintigraphy, with half the usual dose of radionuclide activity. All scans were considered of diagnostic quality. No patient in our study required a ventilation scan. No patient with a negative perfusion scan represented during the 3 month follow up period with PE. We conclude, nuclear medicine imaging is an effective initial investigation for pregnant patients with suspected PE. While scinitigraphy is associated with a greater fetal radiation dose than CTPA, it imparts a lower maternal dose and significantly lower dose to radiosensitive tissues such as breast.

  6. Laparoscopic repair of hiatal hernias: Experience after 200 consecutive cases

    Directory of Open Access Journals (Sweden)

    Bjelović Miloš

    2014-01-01

    Full Text Available Introduction. Repair of hiatal hernias has been performed traditionally via open laparotomy or thoracotomy. Since first laparoscopic hiatal hernia repair in 1992, this method had a growing popularity and today it is the standard approach in experienced centers specialized for minimally invasive surgery. Objective. In the current study we present our experience after 200 consecutive laparoscopic hiatal hernia repairs. Methods. A retrospective cohort study included 200 patients who underwent elective laparoscopic hiatal hernia repair at the Department for Minimally Invasive Upper Digestive Surgery, Clinic for Digestive Surgery, Clinical Center of Serbia in Belgrade from April 2004 to December 2013. Results. Hiatal hernia types included 108 (54% patients with type I, 30 (15% with type III, 62 (31% with giant paraesophageal hernia, while 27 (13.5% patients presented with a chronic gastric volvulus. There were a total of 154 (77% Nissen fundoplications. In 26 (13% cases Nissen procedure was combined with esophageal lengthening procedure (Collis-Nissen, and in 17 (8.5% Toupet fundoplications was performed. Primary retroesophageal crural repair was performed in 164 (82% cases, Cleveland Clinic Foundation suture modification in 27 (13.5%, 4 (2% patients underwent synthetic mesh hiatoplasty, 1 (0.5% primary repair reinforced with pledgets, and 4 (2% autologous fascia lata graft reinforcement. Poor result with anatomic and symptomatic recurrence (indication for revisional surgery was detected in 5 patients (2.7%. Conclusion. Based on the result analysis, we found that laparoscopic hiatal hernia repair was a technically challenging but feasible technique, associated with good to excellent postoperative outcomes comparable to the best open surgery series.

  7. Non-cardiovascular findings in clinical cardiovascular magnetic resonance imaging in children

    International Nuclear Information System (INIS)

    Ghadimi Mahani, Maryam; Morani, Ajaykumar C.; Lu, Jimmy C.; Dorfman, Adam L.; Fazeli Dehkordy, Soudabeh; Jeph, Sunil; Agarwal, Prachi P.

    2016-01-01

    With increasing use of pediatric cardiovascular MRI, it is important for all imagers to become familiar with the spectrum of non-cardiovascular imaging findings that can be encountered. This study aims to ascertain the prevalence and nature of these findings in pediatric cardiovascular MRIs performed at our institution. We retrospectively evaluated reports of all cardiovascular MRI studies performed at our institute from January 2008 to October 2012 in patients younger than18 years. Most studies (98%) were jointly interpreted by a pediatric cardiologist and a radiologist. We reviewed the electronic medical records of all cases with non-cardiovascular findings, defined as any imaging finding outside the cardiovascular system. Non-cardiovascular findings were classified into significant and non-significant, based on whether they were known at the time of imaging or they required additional workup or a change in management. In 849 consecutive studies (mean age 9.7 ± 6.3 years), 145 non-cardiovascular findings were found in 140 studies (16.5% of total studies). Overall, 51.0% (74/145) of non-cardiovascular findings were in the abdomen, 30.3% (44/145) were in the chest, and 18.6% (27/145) were in the spine. A total of 19 significant non-cardiovascular findings were observed in 19 studies in individual patients (2.2% of total studies, 47% male, mean age 5.9 ± 6.7 years). Significant non-cardiovascular findings included hepatic adenoma, arterially enhancing focal liver lesions, asplenia, solitary kidney, pelvicaliectasis, renal cystic diseases, gastric distention, adrenal hemorrhage, lung hypoplasia, air space disease, bronchial narrowing, pneumomediastinum and retained surgical sponge. Non-cardiovascular findings were seen in 16.5% of cardiovascular MRI studies in children, of which 2.2% were clinically significant findings. Prevalence and nature of these non-cardiovascular findings are different from those reported in adults. Attention to these findings is important

  8. Non-cardiovascular findings in clinical cardiovascular magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Ghadimi Mahani, Maryam [University of Michigan Health System, C.S. Mott Children' s Hospital, Department of Radiology, Section of Pediatric Radiology, Ann Arbor, MI (United States); Morani, Ajaykumar C. [The University of Texas MD Anderson Cancer Center, Department of Diagnostic Radiology, Houston, TX (United States); Lu, Jimmy C.; Dorfman, Adam L. [University of Michigan Health System, C.S. Mott Children' s Hospital, Department of Pediatrics and Communicable Diseases, Division of Pediatric Cardiology, Ann Arbor, MI (United States); Fazeli Dehkordy, Soudabeh [University of Michigan Health System, C.S. Mott Children' s Hospital, Department of Radiology, Section of Pediatric Radiology, Ann Arbor, MI (United States); Providence Hospital and Medical Centers, Department of Graduate Medical Education, Southfield, MI (United States); Jeph, Sunil [The University of Texas MD Anderson Cancer Center, Department of Diagnostic Radiology, Houston, TX (United States); Geisinger Medical Center, Department of Radiology, Danville, PA (United States); Agarwal, Prachi P. [University of Michigan Health System, Department of Radiology, Division of Cardiothoracic Radiology, Ann Arbor, MI (United States)

    2016-04-15

    With increasing use of pediatric cardiovascular MRI, it is important for all imagers to become familiar with the spectrum of non-cardiovascular imaging findings that can be encountered. This study aims to ascertain the prevalence and nature of these findings in pediatric cardiovascular MRIs performed at our institution. We retrospectively evaluated reports of all cardiovascular MRI studies performed at our institute from January 2008 to October 2012 in patients younger than18 years. Most studies (98%) were jointly interpreted by a pediatric cardiologist and a radiologist. We reviewed the electronic medical records of all cases with non-cardiovascular findings, defined as any imaging finding outside the cardiovascular system. Non-cardiovascular findings were classified into significant and non-significant, based on whether they were known at the time of imaging or they required additional workup or a change in management. In 849 consecutive studies (mean age 9.7 ± 6.3 years), 145 non-cardiovascular findings were found in 140 studies (16.5% of total studies). Overall, 51.0% (74/145) of non-cardiovascular findings were in the abdomen, 30.3% (44/145) were in the chest, and 18.6% (27/145) were in the spine. A total of 19 significant non-cardiovascular findings were observed in 19 studies in individual patients (2.2% of total studies, 47% male, mean age 5.9 ± 6.7 years). Significant non-cardiovascular findings included hepatic adenoma, arterially enhancing focal liver lesions, asplenia, solitary kidney, pelvicaliectasis, renal cystic diseases, gastric distention, adrenal hemorrhage, lung hypoplasia, air space disease, bronchial narrowing, pneumomediastinum and retained surgical sponge. Non-cardiovascular findings were seen in 16.5% of cardiovascular MRI studies in children, of which 2.2% were clinically significant findings. Prevalence and nature of these non-cardiovascular findings are different from those reported in adults. Attention to these findings is important

  9. Complications and safety aspects of kyphoplasty for osteoporotic vertebral fractures: a prospective follow-up study in 102 consecutive patients

    Directory of Open Access Journals (Sweden)

    Kayser Ralph

    2008-01-01

    Full Text Available Abstract Background Kyphoplasty represents an established minimal-invasive method for correction and augmentation of osteoporotic vertebral fractures. Reliable data on perioperative and postoperative complications are lacking in the literature. The present study was designed to evaluate the incidence and patterns of perioperative complications in order to determine the safety of this procedure for patients undergoing kyphoplasty. Patients and Methods We prospectively enrolled 102 consecutive patients (82 women and 20 men; mean age 69 with 135 operatively treated fractured vertebrae who underwent a kyphoplasty between January 2004 to June 2006. Clinical and radiological follow-up was performed for up 6 months after surgery. Results Preoperative pain levels, as determined by the visual analogous scale (VAS were 7.5 +/- 1.3. Postoperative pain levels were significantly reduced at day 1 after surgery (VAS 2.3 +/- 2.2 and at 6-month follow-up (VAS 1.4 +/- 0.9. Fresh vertebral fractures at adjacent levels were detected radiographically in 8 patients within 6 months. Two patients had a loss of reduction with subsequent sintering of the operated vertebrae and secondary spinal stenosis. Accidental cement extravasation was detected in 7 patients in the intraoperative radiographs. One patient developed a postoperative infected spondylitis at the operated level, which was treated by anterior corporectomy and 360 degrees fusion. Another patient developed a superficial wound infection which required surgical revision. Postoperative bleeding resulting in a subcutaneous haematoma evacuation was seen in one patient. Conclusion The data from the present study imply that percutaneous kyphoplasty can be associated with severe intra- and postoperative complications. This minimal-invasive surgical procedure should therefore be performed exclusively by spine surgeons who have the capability of managing perioperative complications.

  10. Dentofacial effects of bone-anchored maxillary protraction: a controlled study of consecutively treated Class III patients.

    Science.gov (United States)

    De Clerck, Hugo; Cevidanes, Lucia; Baccetti, Tiziano

    2010-11-01

    In this cephalometric investigation, we analyzed the treatment effects of bone-anchored maxillary protraction (BAMP) with miniplates in the maxilla and mandible connected by Class III elastics in patients with Class III malocclusion. The treated sample consisted of 21 Class III patients consecutively treated with the BAMP protocol before the pubertal growth spurt (mean age, 11.10 ± 1.8 years) and reevaluated after BAMP therapy, about 1 year later. The treated group was compared with a matched control group of 18 untreated Class III subjects. Significant differences between the treated and control groups were assessed with independent-sample t tests (P <0.05). Sagittal measurements of the maxilla showed highly significant improvements during active treatment (about 4 mm more than the untreated controls), with significant protraction effects at orbitale and pterygomaxillare. Significant improvements of overjet and molar relationship were recorded, as well as in the mandibular skeletal measures at Point B and pogonion. Vertical skeletal changes and modifications in incisor inclination were negligible, except for a significant proclination of the mandibular incisors in the treated group. Significant soft-tissue changes reflected the underlying skeletal modifications. Compared with growth of the untreated Class III subjects, the BAMP protocol induced an average increment on skeletal and soft-tissue advancement of maxillary structures of about 4 mm, and favorable mandibular changes exceeded 2 mm. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  11. A Study of Identification Performance of Facial Regions from CCTV Images

    NARCIS (Netherlands)

    Ali, Tauseef; Tome, Pedro; Fierrez, Julian; Vera-Rodriguez, Ruben; Spreeuwers, Lieuwe Jan; Veldhuis, Raymond N.J.; Garain, Utpal; Shafait, Faisal

    This paper focuses on automatic face identification for forensic applications. Forensic examiners compare different parts of the face image obtained from a closed-circuit television (CCTV) image with a database of mug shots or good quality image(s) taken from the suspect. In this work we study and

  12. A study of identification performance of facial regions from CCTV images

    NARCIS (Netherlands)

    Ali, Tauseef; Tom, P.; Fierrez, J.; Vera-Rodriguez, R.; Spreeuwers, Lieuwe Jan; Veldhuis, Raymond N.J.

    2012-01-01

    This paper focuses on automatic face identification for forensic applications. Forensic examiners compare different parts of the face image obtained from a closed-circuit television (CCTV) image with a database of mug shots or good quality image(s) taken from the suspect. In this work we study and

  13. Validation of an improved abnormality insertion method for medical image perception investigations

    Science.gov (United States)

    Madsen, Mark T.; Durst, Gregory R.; Caldwell, Robert T.; Schartz, Kevin M.; Thompson, Brad H.; Berbaum, Kevin S.

    2009-02-01

    The ability to insert abnormalities in clinical tomographic images makes image perception studies with medical images practical. We describe a new insertion technique and its experimental validation that uses complementary image masks to select an abnormality from a library and place it at a desired location. The method was validated using a 4-alternative forced-choice experiment. For each case, four quadrants were simultaneously displayed consisting of 5 consecutive frames of a chest CT with a pulmonary nodule. One quadrant was unaltered, while the other 3 had the nodule from the unaltered quadrant artificially inserted. 26 different sets were generated and repeated with order scrambling for a total of 52 cases. The cases were viewed by radiology staff and residents who ranked each quadrant by realistic appearance. On average, the observers were able to correctly identify the unaltered quadrant in 42% of cases, and identify the unaltered quadrant both times it appeared in 25% of cases. Consensus, defined by a majority of readers, correctly identified the unaltered quadrant in only 29% of 52 cases. For repeats, the consensus observer successfully identified the unaltered quadrant only once. We conclude that the insertion method can be used to reliably place abnormalities in perception experiments.

  14. Studying depression using imaging and machine learning methods

    Directory of Open Access Journals (Sweden)

    Meenal J. Patel

    2016-01-01

    Full Text Available Depression is a complex clinical entity that can pose challenges for clinicians regarding both accurate diagnosis and effective timely treatment. These challenges have prompted the development of multiple machine learning methods to help improve the management of this disease. These methods utilize anatomical and physiological data acquired from neuroimaging to create models that can identify depressed patients vs. non-depressed patients and predict treatment outcomes. This article (1 presents a background on depression, imaging, and machine learning methodologies; (2 reviews methodologies of past studies that have used imaging and machine learning to study depression; and (3 suggests directions for future depression-related studies.

  15. Study of check image using computed radiography

    International Nuclear Information System (INIS)

    Sato, Hiroshi

    2002-01-01

    There are two image forming methods both a check image and a portal image in the linacogram. It has been established the image forming method in the check image using computed radiography (CR). On the other hand, it is not established the image forming method in the portal image using CR yet. Usually, in the electric portal imaging device (EPID) is mainly used just before radiotherapy start. The usefulness of the portal image forming method by CR using in place of EPID is possible to confirm the precision for determining to specific position at the irradiate part and to the irradiate method for the human organs. There are some technical problems that, since in the early time, the linac graphy (LG) image have low resolution power. In order to improve to the resolution power in LG image, CR image technologies have been introduced to the check image forming method. Heavy metallic sheet (HMS) is used to the front side of CR-IP cassette, and high contactness sponge is used to the back side of the cassette. Improved contactness between HMS and imaging plate (IP) by means of the high contactness sponge contributed to improve the resolution power in the check images. A lot of paper which is connected with these information have been reported. Imaging plate ST-III should be used to maintain high sensitivity in the check film image forming method. The same image forming method in the check image established by CR has been introduced into the portal image forming method in order to improve the resolution power. However, as a result, it couldn't acquired high resolution image forming in the portal images because of the combination of ST-III and radiotherapy dose. After several trials, it has been recognized that HR-V imaging plate for mammography is the most useful application to maintain high resolution power in the portal images. Also, it is possible to modify the image quality by changing GS parameter which is one of image processing parameters in CR. Furthermore, in case

  16. Clinicopathological and imaging features of breast cancer in Korean Women under 40 years of age

    International Nuclear Information System (INIS)

    Kim, Jun Woo; Jang, Mi Jung; Kim, Sun Mi; Yun, Bo La; Lee, Jong Yoon; Kim, Eun Kyu; Kang, Eun Young; Park, So Yeon

    2017-01-01

    To evaluate the clinicopathological and imaging features of mammography, ultrasonography, and magnetic resonance imaging (MRI) for breast cancer in Korean women under 40 years of age according to molecular subtypes. We included 183 breast cancers in 176 consecutive women under 40 years old who had been diagnosed with breast cancer between January 2012 and November 2014. The patients' clinical and pathologic records were available as electronic medical records. A retrospective review of the pre-operative imaging studies was performed with 177 mammographies, 183 ultrasonographies, and 178 MRIs. Eighty-six percent (158/183) of lesions were symptomatic, with masses (147/183) as the most common presentation. Eighty percent (22/25) of the asymptomatic lesions were diagnosed via screening ultrasonography. The luminal A subtype was the most common (n = 79, 43%), human epidermal growth factor receptor 2-enriched subtype showed indistinct margins on mammography (p = 0.006), the triple negative subtype depicted a posterior enhancement on ultrasonography (p < 0.001) and rim enhancement on MRI (p < 0.001). Breast cancers in Korean women under 40 years of age are commonly presented with a palpable mass, and luminal A is the most common molecular subtype. In our study, the imaging and pathologic characteristics of breast cancer in younger women were similar to those previously reported for older patients

  17. Unique roles of SPET brain imaging in clinical and research studies

    International Nuclear Information System (INIS)

    Seibyl, J.; Jennings, D.; Tabamo, R.; Marek, K.

    2005-01-01

    The increasing availability of PET imaging in Nuclear medicine expands the armamentarium of clinical and research tools for improving diagnosis and treatment of neuropsychiatric disorders. Nonetheless, the role of SPEC imaging remains critical to both research and clinical practice. The development of rational strategies for guiding the selection of imaging modalities flows from primarily the nature of the clinical or research question and the availability of appropriate radiopharmaceuticals. There has been extensive SPECT and PET work in Parkinson's disease (PD) which highlights the value of both these scintigraphic modalities. Three main areas of interest in PD include imaging for improving diagnostic accuracy, for monitoring the progression of disease, and for assessing the therapeutic efficacy of drugs with neoroprotective potential. The demands of the clinical or research question posed to imaging dictates the selection of radiotracer and imaging modality. Diagnosis of PD represents the easiest challenge with many imaging bio markers showing high sensitivity for detecting abnormal reduction of dopaminergic function based on qualitative review of images. On the other hand, using imaging to evaluate treatments which purportedly slow the rate of disease progression, indicated by the reduction of the rate of loss in a quantitative imaging signal in patients studied over time, represents the most rigorous requirement of the imaging measure. In each of these applications presynaptic markers of dopaminergic function using SPECT and PET have been extremely valuable. Review of neuroimaging studies of PD provides a useful example of optimized approaches to clinical and research studies in neuropsychiatric disorders

  18. Single-surgeon fully endoscopic endonasal transsphenoidal surgery: outcomes in three-hundred consecutive cases.

    Science.gov (United States)

    Mamelak, Adam N; Carmichael, John; Bonert, Vivien H; Cooper, Odelia; Melmed, Shlomo

    2013-09-01

    The objective of this study was to evaluate outcomes of endoscopic transsphenoidal surgery using a single-surgeon technique as an alternative to the more commonly employed two-surgeon, three-hand method. Three hundred consecutive endoscopic transsphenoidal procedures performed over a 5 year period from 2006 to 2011 were reviewed. All procedures were performed via a binasal approach utilizing a single surgeon two handed technique with a pneumatic endoscope holder. Expanded enodnansal cases were excluded. Surgical technique, biochemical and surgical outcomes, and complications were analyzed. 276 patients underwent 300 consecutive surgeries with a mean follow-up period of 37 ± 22 months. Non-functioning pituitary adenoma (NFPA) was the most common pathology (n = 152), followed by growth hormone secreting tumors (n = 41) and Rathke's cleft cysts (n = 30). Initial gross total cyst drainage based on radiologic criteria was obtained in 28 cases of Rathke's cleft cyst, with 5 recurrences. For NFPA and other pathologies (n = 173) gross total resection was obtained in 137 cases, with a 92% concordance rate between observed and expected extent of resection. For functional adenoma, remission rates were 30/41 (73%) for GH-secreting, 12/12 (100%) for ACTH-secreting, and 8/17 (47%) for prolactin-secreting tumors. Post-operative complications included transient (11%) and permanent (1.4%) diabetes insipidus, hyponatremia (13%), and new anterior pituitary hormonal deficits (1.4%). CSF leak occurred in 42 cases (15%), and four patients required surgical repair. Two carotid artery injuries occurred, both early in the series. Epistaxis and other rhinological complications were noted in 10% of patients, most of which were minor and diminished as surgical experience increased. Fully endoscopic single surgeon transsphenoidal surgery utilizing a binasal approach and a pneumatic endoscope holder yields outcomes comparable to those reported with a two-surgeon method. Endoscopic outcomes

  19. Magnetic resonance imaging of patellofemoral relationships

    Energy Technology Data Exchange (ETDEWEB)

    Koskinen, S.K. (Dept. of Diagnostic Radiology, Turku Univ. Hospital (Finland)); Taimela, S. (Helsinki Research Inst. for Sports and Exercise Medicine (Finland)); Nelimarkka, O. (Dept. of Surgery, Turku Univ. Hospital (Finland)); Komu, M. (Dept. of Diagnostic Radiology, Turku Univ. Hospital (Finland)); Kujala, U.M. (Helsinki Research Inst. for Sports and Exercise Medicine (Finland))

    1993-08-01

    Patellofemoral relationships were analyzed in 11 patients (13 knees) with patellar dislocation and 15 asymptomatic subjects (15 knees) at 0 and 20 of flexion. The measurements were made from five consecutive axial images through the patellofemoral joint. The six indices measured were lateral patellar tilt (LPT), lateral patellofemoral angle (LPA), lateral patellar displacement (LPD), patella-lateral condyle index (L/PW), congruence angle (CA), and sulcus angle (SA). The reproducibility of the method was evaluated. The difference between the two study groups was more evident at 0 than at 20 of knee flexion. Significant differences were noted between measurements made at different levels of the joint, particularly in the controls. Isometric contraction of the quadriceps muscle lateralized and tilted the patella slightly in both groups. L/PW with and without quadriceps muscle contraction, and LPA with reference to the anterior condyles differentiated between the two study groups most clearly. LPT and LPA with reference to the anterior condyles differentiated the study groups better than LPT and LPA with reference to the posterior condyles. The reproducibility was good except for interobserver comparison of CA and SA. The use of an imaging plane selected at the midpoint of the patellar articular cartilage increases the sensitivity of the measurements, since it takes into account both the height of the patella and the tendency towards lateralization. These results indicate that patellar tilt is best measured with the LPA index and patellar lateralization with the L/PW index at 0 knee flexion. This study should always include isometric contraction of the quadriceps muscle. (orig.)

  20. Magnetic resonance imaging of patellofemoral relationships

    International Nuclear Information System (INIS)

    Koskinen, S.K.; Taimela, S.; Nelimarkka, O.; Komu, M.; Kujala, U.M.

    1993-01-01

    Patellofemoral relationships were analyzed in 11 patients (13 knees) with patellar dislocation and 15 asymptomatic subjects (15 knees) at 0 and 20 of flexion. The measurements were made from five consecutive axial images through the patellofemoral joint. The six indices measured were lateral patellar tilt (LPT), lateral patellofemoral angle (LPA), lateral patellar displacement (LPD), patella-lateral condyle index (L/PW), congruence angle (CA), and sulcus angle (SA). The reproducibility of the method was evaluated. The difference between the two study groups was more evident at 0 than at 20 of knee flexion. Significant differences were noted between measurements made at different levels of the joint, particularly in the controls. Isometric contraction of the quadriceps muscle lateralized and tilted the patella slightly in both groups. L/PW with and without quadriceps muscle contraction, and LPA with reference to the anterior condyles differentiated between the two study groups most clearly. LPT and LPA with reference to the anterior condyles differentiated the study groups better than LPT and LPA with reference to the posterior condyles. The reproducibility was good except for interobserver comparison of CA and SA. The use of an imaging plane selected at the midpoint of the patellar articular cartilage increases the sensitivity of the measurements, since it takes into account both the height of the patella and the tendency towards lateralization. These results indicate that patellar tilt is best measured with the LPA index and patellar lateralization with the L/PW index at 0 knee flexion. This study should always include isometric contraction of the quadriceps muscle. (orig.)

  1. The diagnostic accuracy of 1.5T magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries.

    Science.gov (United States)

    Wade, Ryckie G; Itte, Vinay; Rankine, James J; Ridgway, John P; Bourke, Grainne

    2018-03-01

    Identification of root avulsions is of critical importance in traumatic brachial plexus injuries because it alters the reconstruction and prognosis. Pre-operative magnetic resonance imaging is gaining popularity, but there is limited and conflicting data on its diagnostic accuracy for root avulsion. This cohort study describes consecutive patients requiring brachial plexus exploration following trauma between 2008 and 2016. The index test was magnetic resonance imaging at 1.5 Tesla and the reference test was operative exploration of the supraclavicular plexus. Complete data from 29 males was available. The diagnostic accuracy of magnetic resonance imaging for root avulsion(s) of C5-T1 was 79%. The diagnostic accuracy of a pseudomeningocoele as a surrogate marker of root avulsion(s) of C5-T1 was 68%. We conclude that pseudomeningocoles were not a reliable sign of root avulsion and magnetic resonance imaging has modest diagnostic accuracy for root avulsions in the context of adult traumatic brachial plexus injuries. III.

  2. Interaction of Pseudostellaria heterophylla with Fusarium oxysporum f.sp. heterophylla mediated by its root exudates in a consecutive monoculture system.

    Science.gov (United States)

    Zhao, Yongpo; Wu, Linkun; Chu, Leixia; Yang, Yanqiu; Li, Zhenfang; Azeem, Saadia; Zhang, Zhixing; Fang, Changxun; Lin, Wenxiong

    2015-02-03

    In this study, quantitative real-time PCR (qPCR) was used to determine the amount of Fusarium oxysporum, an important replant disease pathogen in Pseudostellaria heterophylla rhizospheric soil. Moreover, HPLC was used to identify phenolic acids in root exudates then it was further to explore the effects of the phenolic acid allelochemicals on the growth of F. oxysporum f.sp. heterophylla. The amount of F. oxysporum increased significantly in P. heterophylla rhizosphere soil under a consecutive replant system as monitored through qPCR analysis. Furthermore, the growth of F. oxysporum f.sp. heterophylla mycelium was enhanced by root exudates with a maximum increase of 23.8%. In addition, the number of spores increased to a maximum of 12.5-fold. Some phenolic acids promoted the growth of F. oxysporum f.sp. heterophylla mycelium and spore production. Our study revealed that phenolic acids in the root secretion of P. heterophylla increased long with its development, which was closely related to changes in rhizospheric microorganisms. The population of pathogenic microorganisms such as F. oxysporum in the rhizosphere soil of P. heterophylla also sharply increased. Our results on plant-microbe communication will help to better clarify the cause of problems associated with P. heterophylla under consecutive monoculture treatment.

  3. Fuel assembly assessment from CVD image analysis: A feasibility study

    International Nuclear Information System (INIS)

    Lindsay, C.S.; Lindblad, T.

    1997-05-01

    The Swedish Nuclear Inspectorate commissioned a feasibility study of automatic assessment of fuel assemblies from images obtained with the digital Cerenkov viewing device currently in development. The goal is to assist the IAEA inspectors in evaluating the fuel since they typically have only a few seconds to inspect an assembly. We report results here in two main areas: Investigation of basic image processing and recognition techniques needed to enhance the images and find the assembly in the image; Study of the properties of the distributions of light from the assemblies to determine whether they provide unique signatures for different burn-up and cooling times for real fuel or indicate presence of non-fuel. 8 refs, 27 figs

  4. Comparative assessments of the effects of alcohol exposure on fetal brain development using optical coherence tomography and ultrasound imaging

    Science.gov (United States)

    Sudheendran, Narendran; Bake, Shameena; Miranda, Rajesh C.; Larin, Kirill V.

    2013-02-01

    The developing fetal brain is vulnerable to a variety of environmental agents including maternal ethanol consumption. Preclinical studies on the development and amelioration of fetal teratology would be significantly facilitated by the application of high resolution imaging technologies like optical coherence tomography (OCT) and high-frequency ultrasound (US). This study investigates the ability of these imaging technologies to measure the effects of maternal ethanol exposure on brain development, ex vivo, in fetal mice. Pregnant mice at gestational day 12.5 were administered ethanol (3 g/Kg b.wt.) or water by intragastric gavage, twice daily for three consecutive days. On gestational day 14.5, fetuses were collected and imaged. Three-dimensional images of the mice fetus brains were obtained by OCT and high-resolution US, and the volumes of the left and right ventricles of the brain were measured. Ethanol-exposed fetuses exhibited a statistically significant, 2-fold increase in average left and right ventricular volumes compared with the ventricular volume of control fetuses, with OCT-derived measures of 0.38 and 0.18 mm3, respectively, whereas the boundaries of the fetal mouse lateral ventricles were not clearly definable with US imaging. Our results indicate that OCT is a useful technology for assessing ventriculomegaly accompanying alcohol-induced developmental delay. This study clearly demonstrated advantages of using OCT for quantitative assessment of embryonic development compared with US imaging.

  5. A comparative analysis of pulmonary ventilation-perfusion imaging with pulmonary angiography in the diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Wang Jincheng; Mi Hongzhi; Wang Qian; Zhang Weijun; Lu Biao; Yang Hao; Ding Jian; Lu Yao

    2001-01-01

    Objective: To assess the value of ventilation-perfusion imaging in the diagnosis of pulmonary embolism (PE). Methods: Thirty consecutive patients with clinically suspected pulmonary embolism were studied, male: female 15:15, mean age was (36.2 +- 13.9) years. The chest radiograms were obtained in all 30 patients. All patients underwent radionuclide ventilation-perfusion imaging and pulmonary angiography. Results: Of the 30 patients, 22 with lobe, multiple segment or multi-subsegment perfusion defects and normal or nearly normal ventilation images were reported as PE. 20 of them were confirmed to be with PE by pulmonary angiography, 2 patients were not confirmed. Eight of 30 patients with multiple perfusion defects, ventilative abnormalities were reported as non-PE and the diagnoses were confirmed by pulmonary angiography. The sensitivity, specificity and accuracy of diagnosis of PE by ventilation-perfusion imaging was 100%, 80.0% and 93.3% respectively. Conclusions: (1) Ventilation-perfusion imaging is one of the most valuable methods in the diagnosis of PE. (2) The results suggest that pulmonary embolism can be diagnosed non-invasively in most patients on the basis of clinical manifestation, chest radiograms and ventilation-perfusion imaging findings. (3) Pulmonary angiography is required while clinical manifestation and ventilation-perfusion imaging findings are discordant with each other

  6. A study of television imaging system for fast neutron radiography

    International Nuclear Information System (INIS)

    Yoshii, Koji

    1992-01-01

    The neutron radiography with fast neutron beam is a very useful imaging technique for thicker objects, especially those composed of hydrogen-rich materials which are sometimes difficult to image by thermal neutron radiography. The fast neutron radiography has not been studied so much as the thermal neutron radiography. The fast neutron radiography has been studied at the fast neutron source reactor 'Yayoi' of the University of Tokyo built in Tokai-mura. The average neutron energy of the Yayoi is about 1 MeV, and the peak neutron flux at the core center is 0.8 x 10 12 at the maximum operating power of 2 kW. In the experiment on fast neutron radiography, a CR39 nuclear track detector has been used successfully. But in the Yayoi radiography procedure, about 24 hours were required for obtaining an imaging result. To get a prompt imaging result and a real-time imaging result, it is necessary to develop a fast neutron television system, and in this paper, a new fast neutron TV system is proposed. The main difference is the converter material sensitive to fast neutrons. The study on the fast neutron TV system was carried out by using the Baby Cyclotron of Japan Steel Works, and the good images were realized. (K.I.)

  7. Moving object detection in top-view aerial videos improved by image stacking

    Science.gov (United States)

    Teutsch, Michael; Krüger, Wolfgang; Beyerer, Jürgen

    2017-08-01

    Image stacking is a well-known method that is used to improve the quality of images in video data. A set of consecutive images is aligned by applying image registration and warping. In the resulting image stack, each pixel has redundant information about its intensity value. This redundant information can be used to suppress image noise, resharpen blurry images, or even enhance the spatial image resolution as done in super-resolution. Small moving objects in the videos usually get blurred or distorted by image stacking and thus need to be handled explicitly. We use image stacking in an innovative way: image registration is applied to small moving objects only, and image warping blurs the stationary background that surrounds the moving objects. Our video data are coming from a small fixed-wing unmanned aerial vehicle (UAV) that acquires top-view gray-value images of urban scenes. Moving objects are mainly cars but also other vehicles such as motorcycles. The resulting images, after applying our proposed image stacking approach, are used to improve baseline algorithms for vehicle detection and segmentation. We improve precision and recall by up to 0.011, which corresponds to a reduction of the number of false positive and false negative detections by more than 3 per second. Furthermore, we show how our proposed image stacking approach can be implemented efficiently.

  8. Scatterometry or imaging overlay: a comparative study

    Science.gov (United States)

    Hsu, Simon C. C.; Pai, Yuan Chi; Chen, Charlie; Yu, Chun Chi; Hsing, Henry; Wu, Hsing-Chien; Kuo, Kelly T. L.; Amir, Nuriel

    2015-03-01

    Most fabrication facilities today use imaging overlay measurement methods, as it has been the industry's reliable workhorse for decades. In the last few years, third-generation Scatterometry Overlay (SCOL™) or Diffraction Based Overlay (DBO-1) technology was developed, along another DBO technology (DBO-2). This development led to the question of where the DBO technology should be implemented for overlay measurements. Scatterometry has been adopted for high volume production in only few cases, always with imaging as a backup, but scatterometry overlay is considered by many as the technology of the future. In this paper we compare imaging overlay and DBO technologies by means of measurements and simulations. We outline issues and sensitivities for both technologies, providing guidelines for the best implementation of each. For several of the presented cases, data from two different DBO technologies are compared as well, the first with Pupil data access (DBO-1) and the other without pupil data access (DBO-2). Key indicators of overlay measurement quality include: layer coverage, accuracy, TMU, process robustness and robustness to process changes. Measurement data from real cases across the industry are compared and the conclusions are also backed by simulations. Accuracy is benchmarked with reference OVL, and self-consistency, showing good results for Imaging and DBO-1 technology. Process sensitivity and metrology robustness are mostly simulated with MTD (Metrology Target Designer) comparing the same process variations for both technologies. The experimental data presented in this study was done on ten advanced node layers and three production node layers, for all phases of the IC fabrication process (FEOL, MEOL and BEOL). The metrology tool used for most of the study is KLA-Tencor's Archer 500LCM system (scatterometry-based and imaging-based measurement technologies on the same tool) another type of tool is used for DBO-2 measurements. Finally, we conclude that

  9. Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology study

    Directory of Open Access Journals (Sweden)

    Schiattarella Pier

    2010-11-01

    Full Text Available Abstract Miniaturization has evolved in the creation of a pocket-size imaging device which can be utilized as an ultrasound stethoscope. This study assessed the additional diagnostic power of pocket size device by both experts operators and trainees in comparison with physical examination and its appropriateness of use in comparison with standard echo machine in a non-cardiologic population. Three hundred four consecutive non cardiologic outpatients underwent a sequential assessment including physical examination, pocket size imaging device and standard Doppler-echo exam. Pocket size device was used by both expert operators and trainees (who received specific training before the beginning of the study. All the operators were requested to give only visual, qualitative insights on specific issues. All standard Doppler-echo exams were performed by expert operators. One hundred two pocket size device exams were performed by experts and two hundred two by trainees. The time duration of the pocket size device exam was 304 ± 117 sec. Diagnosis of cardiac abnormalities was made in 38.2% of cases by physical examination and in 69.7% of cases by physical examination + pocket size device (additional diagnostic power = 31.5%, p In conclusion, pocket size device showed a relevant additional diagnostic value in comparison with physical examination. Sensitivity and specificity were good in experts and suboptimal in trainees. Specificity was particularly influenced by the level of experience. Training programs are needed for pocket size device users.

  10. Imaging appearance of dextranomer/hyaluronic acid copolymer implant injections for treatment of velopharyngeal insufficiency.

    Science.gov (United States)

    Brinjikji, W; Cofer, S A; Lane, J I

    2015-06-01

    Dextranomer/hyaluronic acid copolymer implants are used in treating velopharyngeal insufficiency. These posterior nasopharyngeal implants can be mistaken for pathologic conditions such as retropharyngeal abscess on imaging. We studied the imaging appearance of dextranomer/hyaluronic acid copolymer implants in patients treated for velopharyngeal insufficiency. A consecutive series of patients with velopharyngeal insufficiency treated with dextranomer/hyaluronic acid copolymer were included in this study. Data on patient characteristics and volume of dextranomer/hyaluronic acid copolymer injected were obtained. Postoperative imaging characteristics on plain radiography, CT, and MR imaging were assessed. The imaging appearance of postoperative complications was determined. Sixteen patients were included in this study. Seven patients underwent postoperative plain radiographs, 5 patients underwent CT, and 9 patients underwent MR imaging. Plain radiographs demonstrated soft-tissue swelling in the retropharyngeal space, which resolved at 1 month. On CT, dextranomer/hyaluronic acid copolymer implants appeared as bilateral nasopharyngeal soft-tissue masses isoattenuated to hypoattenuated relative to muscle in 80% (4/5) of patients. On MR imaging, dextranomer/hyaluronic acid copolymer implants appeared as bilateral nasopharyngeal soft-tissue masses that were isointense to muscle on T1 (8/9, 88.9%) and hyperintense to muscle on T2 (8/9, 88.9%) and demonstrated no restricted diffusion (4/4, 100.0%) or peripheral enhancement (7/7, 100.0%). The normal postoperative findings of posterior nasopharyngeal dextranomer/hyaluronic acid copolymer injection on MR imaging is characterized by the presence of bilateral nasopharyngeal soft-tissue masses that are isointense to muscle on T1 and hyperintense on T2, with no restricted diffusion or peripheral enhancement. Velopharyngeal dextranomer/hyaluronic acid copolymer implants are iso- to hypoattenuated to muscle on CT and are not visible

  11. Attenuated hypocholesterolemia following severe trauma signals risk for late ventilator-associated pneumonia, ventilator dependency, and death: a retrospective study of consecutive patients

    Directory of Open Access Journals (Sweden)

    Chirichella Thomas J

    2011-03-01

    Full Text Available Abstract Background Post-traumatic ventilator-associated pneumonia (VAP is a substantial clinical problem that increases hospital costs and typically adds to the duration of mechanical ventilation. We evaluated the impact of VAP on ventilator days. We also assessed 48-hour total blood cholesterol (TC and other potential risk factors for the development of VAP. Methods We performed a retrospective study of consecutive trauma patients requiring emergency tracheal intubation and evaluated TC, age, gender, ethanol status, smoker status, injury mechanism, chest injury, brain injury, Injury Severity Score (ISS, shock, day-one hypoxemia, and RBC transfusion as potential risks for VAP. Results The 152 patients had ISS 28.1, brain injury 68.4%, VAP 50.0%, ventilator days 14.3, and death 9.9%. Ventilator days were increased with late VAP (p Conclusions Severe traumatic injury produced substantial hypocholesterolemia that is greater with chest injury, shock, and RBC transfusion, but less with brain injury. Total blood cholesterol tended to decrease with increasing injury severity. However, attenuated hypocholesterolemia (ISS ≥ 20-&-TC ≥ 90 mg/dL represents a unique response that can occur with critical injury. Attenuated hypocholesterolemia signals early risk for late VAP, ventilator dependency, and death.

  12. Validation of a Smartphone Image-Based Dietary Assessment Method for Pregnant Women

    Directory of Open Access Journals (Sweden)

    Amy M. Ashman

    2017-01-01

    Full Text Available Image-based dietary records could lower participant burden associated with traditional prospective methods of dietary assessment. They have been used in children, adolescents and adults, but have not been evaluated in pregnant women. The current study evaluated relative validity of the DietBytes image-based dietary assessment method for assessing energy and nutrient intakes. Pregnant women collected image-based dietary records (via a smartphone application of all food, drinks and supplements consumed over three non-consecutive days. Intakes from the image-based method were compared to intakes collected from three 24-h recalls, taken on random days; once per week, in the weeks following the image-based record. Data were analyzed using nutrient analysis software. Agreement between methods was ascertained using Pearson correlations and Bland-Altman plots. Twenty-five women (27 recruited, one withdrew, one incomplete, median age 29 years, 15 primiparas, eight Aboriginal Australians, completed image-based records for analysis. Significant correlations between the two methods were observed for energy, macronutrients and fiber (r = 0.58–0.84, all p < 0.05, and for micronutrients both including (r = 0.47–0.94, all p < 0.05 and excluding (r = 0.40–0.85, all p < 0.05 supplements in the analysis. Bland-Altman plots confirmed acceptable agreement with no systematic bias. The DietBytes method demonstrated acceptable relative validity for assessment of nutrient intakes of pregnant women.

  13. The ovulation pattern during three consecutive menstrual cycles has a significant impact on pregnancy rate and sex of the offspring

    DEFF Research Database (Denmark)

    Fukuda, Misao; Fukuda, Kiyomi; Tatsumi, Kenichi

    2011-01-01

    Identification of the ovary at the time of ovulation during three consecutive menstrual cycles results in one of eight ovulation patterns, left-left-right, right-left-right, left-right-right, and right-right-right of right-sided ovulation and right-right-left, left-right-left, right-left-left, an......Identification of the ovary at the time of ovulation during three consecutive menstrual cycles results in one of eight ovulation patterns, left-left-right, right-left-right, left-right-right, and right-right-right of right-sided ovulation and right-right-left, left-right-left, right...

  14. Clinical findings versus imaging studies in the diagnosis of infantile ...

    African Journals Online (AJOL)

    Background: Infantile hypertrophic pyloric stenosis is the most common surgical cause of vomiting in early infancy and can be diagnosed clinically or by imaging studies. Objectives: The aim of this study was to assess the accuracy of clinical examination compared with ultrasound and upper gastrointestinal contrast imaging ...

  15. Automatic image fusion of real-time ultrasound with computed tomography images: a prospective comparison between two auto-registration methods.

    Science.gov (United States)

    Cha, Dong Ik; Lee, Min Woo; Kim, Ah Yeong; Kang, Tae Wook; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga

    2017-11-01

    Background A major drawback of conventional manual image fusion is that the process may be complex, especially for less-experienced operators. Recently, two automatic image fusion techniques called Positioning and Sweeping auto-registration have been developed. Purpose To compare the accuracy and required time for image fusion of real-time ultrasonography (US) and computed tomography (CT) images between Positioning and Sweeping auto-registration. Material and Methods Eighteen consecutive patients referred for planning US for radiofrequency ablation or biopsy for focal hepatic lesions were enrolled. Image fusion using both auto-registration methods was performed for each patient. Registration error, time required for image fusion, and number of point locks used were compared using the Wilcoxon signed rank test. Results Image fusion was successful in all patients. Positioning auto-registration was significantly faster than Sweeping auto-registration for both initial (median, 11 s [range, 3-16 s] vs. 32 s [range, 21-38 s]; P auto-registration was significantly higher for initial image fusion (median, 38.8 mm [range, 16.0-84.6 mm] vs. 18.2 mm [6.7-73.4 mm]; P = 0.029), but not for complete image fusion (median, 4.75 mm [range, 1.7-9.9 mm] vs. 5.8 mm [range, 2.0-13.0 mm]; P = 0.338]. Number of point locks required to refine the initially fused images was significantly higher with Positioning auto-registration (median, 2 [range, 2-3] vs. 1 [range, 1-2]; P = 0.012]. Conclusion Positioning auto-registration offers faster image fusion between real-time US and pre-procedural CT images than Sweeping auto-registration. The final registration error is similar between the two methods.

  16. Exercise thallium-201 imaging in complete left bundle branch block and the prevalence of septal perfusion defects

    International Nuclear Information System (INIS)

    Jazmati, B.; Sadaniantz, A.; Emaus, S.P.; Heller, G.V.

    1991-01-01

    To determine the prevalence of septal defects in a generalized referral population, the records of 93 consecutive patients with complete left bundle branch block (BBB) who underwent symptom-limited treadmill exercise testing with thallium-201 myocardial imaging over a 3-year period were reviewed. Segmental analysis of the planar thallium-201 images was performed in a blinded fashion with agreement by consensus. Computerized quantitative analysis of the images also was independently performed, and was correlated with the visual interpretations. Forty-seven patients (51%) had normal images, and 46 (49%) had defects of greater than or equal to 2 segments. In the abnormal studies, only 13 patients (14% of the total population) had septal defects, while a much higher number of patients, 33 (39%), had inferior or apical defects, or both. Coronary angiography was performed in 6 patients with septal defects: Significant narrowing of the left anterior descending coronary artery was found in 4 patients, a narrowed right coronary artery was found in 1, and normal coronary arteries were seen in the other patient. In conclusion, whereas previous studies have suggested a high percentage of false-positive septal defects in patients with left BBB, this study demonstrates a low prevalence (14%) of septal defects in a large population of unselected patients presenting for exercise thallium-201 imaging. Therefore, exercise thallium-201 imaging remains a useful procedure for evaluating patients with complete left BBB

  17. Effects of silicone expanders and implants on echocardiographic image quality after breast reconstruction.

    Science.gov (United States)

    Pignatti, Marco; Mantovani, Francesca; Bertelli, Luca; Barbieri, Andrea; Pacchioni, Lucrezia; Loschi, Pietro; De Santis, Giorgio

    2013-08-01

    Use of silicone expanders and implants is the most common breast reconstruction technique after mastectomy. Postmastectomy patients often need echocardiographic monitoring of potential cardiotoxicity induced by cancer chemotherapy. The impairment of the echocardiographic acoustic window caused by silicone implants for breast augmentation has been reported. This study investigates whether the echocardiographic image quality was impaired in women reconstructed with silicone expanders and implants. The records of 44 consecutive women who underwent echocardiographic follow-up after breast reconstruction with expanders and implants at the authors' institution from January of 2000 to August of 2012 were reviewed. The population was divided into a study group (left or bilateral breast expanders/implants, n=30) and a control group (right breast expanders/implants, n=14). The impact of breast expanders/implants on echocardiographic image quality was tested (analysis of covariance model). Patients with a breast expander/implant (left or bilateral and right breast expanders/implants) were included. The mean volume of the breast devices was 353.2±125.5 cc. The quality of the echocardiographic images was good or sufficient in the control group; in the study group, it was judged as adequate in only 50 percent of cases (15 patients) and inadequate in the remaining 15 patients (pimplants in postmastectomy left breast reconstruction considerably reduce the image quality of echocardiography. This may have important clinical implications, given the need for periodic echocardiographic surveillance before and during chemotherapy. Therapeutic, III.

  18. Changes of radio-technological studies in the field of medical imaging. From analogous studies to digital ones

    International Nuclear Information System (INIS)

    Shiraishi, Junji; Uchiyama, Yoshikazu; Honda, Michitaka; Ogura, Toshihiro; Kunitomo, Hiroshi; Kishimoto, Kenji; Ishii, Rie; Hara, Takeshi; Tanaka, Rie

    2014-01-01

    Eight authors briefly describe practical reviews of domestic changes in the title of their expertized field for the purpose of enlightenment. Reviews concern following studies: on the construction of medical images, on characteristics of input/output, of resolution, of noise, on whole assessment of images with noise-equivalent number of quanta/detective quantum efficiency (NEQ/DQE), with subjectivity, on computer-aided diagnosis (CAD), and on image displaying system assessment. X-ray image subtraction along with the development of CT is the origin of real-time digitalized image construction. Studies on the input/output affects the quality of images and exposure dose to patients, which have contributed to works of investigators at manufacturing and technologists on site. Then described are changes in the assessment of image by digital radiography (DR), of which basis was originally established at analogous sensitizer/film (S/F) era, of image resolution and of noise characteristic assessment, during the period from S/F to DR systems. Assessment of images with NEQ/DQE has been essentially based on the description in the 'Image Science' published in 1974 and its derived domestic educational researches; and the assessment with subjectivity involves the receiver operating characteristic (ROC), which leads to computer-aided diagnosis (CAD). Studies on image display are now changing responding to clinical and social needs. (T.T.)

  19. Diagnosis of partial and complete rotator cuff tears using combined gradient echo and spin echo imaging

    International Nuclear Information System (INIS)

    Tuite, M.J.; Yandow, D.R.; DeSmet, A.A.; Orwin, J.F.; Quintana, F.A.

    1994-01-01

    Most magnetic resonance (MR) studies evaluating the rotator cuff for tears have used T2-weighted imaging in the coronal oblique and sagittal oblique planes. T2 * -weighted gradient echo imaging, however, has advantages over spin echo imaging, including contiguous slices without cross-talk, high contrast around the cuff, and intrinsically shorter imaging times which can be used to increase the number of signals averaged and thus improve the signal-to-noise ratio. We reviewed the shoulder MR scans of 87 consecutive patients who underwent both a MR scan and a shoulder arthroscopy during which the size of tears, if present, was graded. The reviewers were blinded as to the history and arthroscopic results. The MR scans included oblique coronal T2 * -weighted gradient echo and oblique sagittal T2-weighted spin echo images. MR cuff grades were correlated with arthroscopic findings. For complete tears, the sensitivity of MR was 0.91 and the specificity 0.95. For partial tears, the sensitivity was 0.74 and the specificity 0.87. This accuracy is similar to two-plane T2-weighted imaging as previously reported in the literature. There was a statistically significant correlation (p < 0.0005) between the cuff grade as determined by MR and the arthroscopic findings. (orig.)

  20. Diagnosis of partial and complete rotator cuff tears using combined gradient echo and spin echo imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J [Dept. of Radiology, Univ. of Wisconsin, Madison, WI (United States); Yandow, D R [Dept. of Radiology, Univ. of Wisconsin, Madison, WI (United States); DeSmet, A A [Dept. of Radiology, Univ. of Wisconsin, Madison, WI (United States); Orwin, J F [Div. of Orthopedic Surgery, Univ. of Wisconsin, Madison, WI (United States); Quintana, F A [Dept. of Biostatistics, Univ. of Wisconsin, Madison, WI (United States)

    1994-10-01

    Most magnetic resonance (MR) studies evaluating the rotator cuff for tears have used T2-weighted imaging in the coronal oblique and sagittal oblique planes. T2{sup *}-weighted gradient echo imaging, however, has advantages over spin echo imaging, including contiguous slices without cross-talk, high contrast around the cuff, and intrinsically shorter imaging times which can be used to increase the number of signals averaged and thus improve the signal-to-noise ratio. We reviewed the shoulder MR scans of 87 consecutive patients who underwent both a MR scan and a shoulder arthroscopy during which the size of tears, if present, was graded. The reviewers were blinded as to the history and arthroscopic results. The MR scans included oblique coronal T2{sup *}-weighted gradient echo and oblique sagittal T2-weighted spin echo images. MR cuff grades were correlated with arthroscopic findings. For complete tears, the sensitivity of MR was 0.91 and the specificity 0.95. For partial tears, the sensitivity was 0.74 and the specificity 0.87. This accuracy is similar to two-plane T2-weighted imaging as previously reported in the literature. There was a statistically significant correlation (p < 0.0005) between the cuff grade as determined by MR and the arthroscopic findings. (orig.)

  1. Feasibility study and quality assessment of unmanned aircraft system-derived multispectral images

    Science.gov (United States)

    Chang, Kuo-Jen

    2017-04-01

    The purpose of study is to explore the precision and the applicability of UAS-derived multispectral images. In this study, the Micro-MCA6 multispectral camera was mounted on quadcopter. The Micro-MCA6 shoot images synchronized of each single band. By means of geotagged images and control points, the orthomosaic images of each single band generated firstly by 14cm resolution. The multispectral image was merged complete with 6 bands. In order to improve the spatial resolution, the 6 band image fused with 9cm resolution image taken from RGB camera. Quality evaluation of the image is verified of the each single band by using control points and check points. The standard deviations of errors are within 1 to 2 pixel resolution of each band. The quality of the multispectral image is compared with 3 cm resolution orthomosaic RGB image gathered from UAV in the same mission, as well. The standard deviations of errors are within 2 to 3 pixel resolution. The result shows that the errors resulting from the blurry and the band dislocation of the objects edge identification. To the end, the normalized difference vegetation index (NDVI) extracted from the image to explore the condition of vegetation and the nature of the environment. This study demonstrates the feasibility and the capability of the high resolution multispectral images.

  2. Processed images in human perception: A case study in ultrasound breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yap, Moi Hoon [Department of Computer Science, Loughborough University, FH09, Ergonomics and Safety Research Institute, Holywell Park (United Kingdom)], E-mail: M.H.Yap@lboro.ac.uk; Edirisinghe, Eran [Department of Computer Science, Loughborough University, FJ.05, Garendon Wing, Holywell Park, Loughborough LE11 3TU (United Kingdom); Bez, Helmut [Department of Computer Science, Loughborough University, Room N.2.26, Haslegrave Building, Loughborough University, Loughborough LE11 3TU (United Kingdom)

    2010-03-15

    Two main research efforts in early detection of breast cancer include the development of software tools to assist radiologists in identifying abnormalities and the development of training tools to enhance their skills. Medical image analysis systems, widely known as Computer-Aided Diagnosis (CADx) systems, play an important role in this respect. Often it is important to determine whether there is a benefit in including computer-processed images in the development of such software tools. In this paper, we investigate the effects of computer-processed images in improving human performance in ultrasound breast cancer detection (a perceptual task) and classification (a cognitive task). A survey was conducted on a group of expert radiologists and a group of non-radiologists. In our experiments, random test images from a large database of ultrasound images were presented to subjects. In order to gather appropriate formal feedback, questionnaires were prepared to comment on random selections of original images only, and on image pairs consisting of original images displayed alongside computer-processed images. We critically compare and contrast the performance of the two groups according to perceptual and cognitive tasks. From a Receiver Operating Curve (ROC) analysis, we conclude that the provision of computer-processed images alongside the original ultrasound images, significantly improve the perceptual tasks of non-radiologists but only marginal improvements are shown in the perceptual and cognitive tasks of the group of expert radiologists.

  3. Processed images in human perception: A case study in ultrasound breast imaging

    International Nuclear Information System (INIS)

    Yap, Moi Hoon; Edirisinghe, Eran; Bez, Helmut

    2010-01-01

    Two main research efforts in early detection of breast cancer include the development of software tools to assist radiologists in identifying abnormalities and the development of training tools to enhance their skills. Medical image analysis systems, widely known as Computer-Aided Diagnosis (CADx) systems, play an important role in this respect. Often it is important to determine whether there is a benefit in including computer-processed images in the development of such software tools. In this paper, we investigate the effects of computer-processed images in improving human performance in ultrasound breast cancer detection (a perceptual task) and classification (a cognitive task). A survey was conducted on a group of expert radiologists and a group of non-radiologists. In our experiments, random test images from a large database of ultrasound images were presented to subjects. In order to gather appropriate formal feedback, questionnaires were prepared to comment on random selections of original images only, and on image pairs consisting of original images displayed alongside computer-processed images. We critically compare and contrast the performance of the two groups according to perceptual and cognitive tasks. From a Receiver Operating Curve (ROC) analysis, we conclude that the provision of computer-processed images alongside the original ultrasound images, significantly improve the perceptual tasks of non-radiologists but only marginal improvements are shown in the perceptual and cognitive tasks of the group of expert radiologists.

  4. Multichannel imager for littoral zone characterization

    Science.gov (United States)

    Podobna, Yuliya; Schoonmaker, Jon; Dirbas, Joe; Sofianos, James; Boucher, Cynthia; Gilbert, Gary

    2010-04-01

    This paper describes an approach to utilize a multi-channel, multi-spectral electro-optic (EO) system for littoral zone characterization. Advanced Coherent Technologies, LLC (ACT) presents their EO sensor systems for the surf zone environmental assessment and potential surf zone target detection. Specifically, an approach is presented to determine a Surf Zone Index (SZI) from the multi-spectral EO sensor system. SZI provides a single quantitative value of the surf zone conditions delivering an immediate understanding of the area and an assessment as to how well an airborne optical system might perform in a mine countermeasures (MCM) operation. Utilizing consecutive frames of SZI images, ACT is able to measure variability over time. A surf zone nomograph, which incorporates targets, sensor, and environmental data, including the SZI to determine the environmental impact on system performance, is reviewed in this work. ACT's electro-optical multi-channel, multi-spectral imaging system and test results are presented and discussed.

  5. Infrared and visible image fusion using discrete cosine transform and swarm intelligence for surveillance applications

    Science.gov (United States)

    Paramanandham, Nirmala; Rajendiran, Kishore

    2018-01-01

    A novel image fusion technique is presented for integrating infrared and visible images. Integration of images from the same or various sensing modalities can deliver the required information that cannot be delivered by viewing the sensor outputs individually and consecutively. In this paper, a swarm intelligence based image fusion technique using discrete cosine transform (DCT) domain is proposed for surveillance application which integrates the infrared image with the visible image for generating a single informative fused image. Particle swarm optimization (PSO) is used in the fusion process for obtaining the optimized weighting factor. These optimized weighting factors are used for fusing the DCT coefficients of visible and infrared images. Inverse DCT is applied for obtaining the initial fused image. An enhanced fused image is obtained through adaptive histogram equalization for a better visual understanding and target detection. The proposed framework is evaluated using quantitative metrics such as standard deviation, spatial frequency, entropy and mean gradient. The experimental results demonstrate the outperformance of the proposed algorithm over many other state- of- the- art techniques reported in literature.

  6. Malignant gliomas (MG) in the elderly. A study of 85 consecutive patients in two institutions

    International Nuclear Information System (INIS)

    Villa, S.; Vinolas, N.; Verger, E.; Gil, M.; Caralt, L.; Moreno, V.; Graus, F.

    1997-01-01

    Purpose: The treatment of MG in old patients is controversial and not well established. Some authors consider that adjuvant radiotherapy (RT) is not useful to improve survival. Our aim was to identify which group of patients older than 65 years might benefit of adjuvant radiotherapy (RT). Patients and Methods: A total of 85 consecutive patients were analyzed from two Institutions diagnosed during the period 1987-1995. Forty six were male and 39 female. The median age was 70 (r 65-81). The extent of surgery (S) was analyzed by neurosurgeons reports or postoperative CT scan (32 p. underwent biopsy, 25 partial resection, 28 complete resection). Glioblastoma Multiforme was observed in 64 patients (75%) and anaplastic gliomas in 21 patients (25%). Postoperative Karnofsky Index (KI) was as follows: in 47 p 60% (for 2 p was unknown). Survival probability was estimated using Kaplan-Meier method and compared with log-rank test. Crude and adjusted hazard ratios (HR) were calculated using Cox's regression models. Results: Forty four patients were treated by adjuvant RT and 41 patients were not. Median survival time for all patients was 18.3 weeks. In multivariate analysis we found that the most powerful independent variable was not to receive RT with a hazard ratio of 8.5 (CI 4.55-16.06). Reasons for not RT were: in 7 p. postsurgical complications, in 17 p. KI 40%. Multivariate analysis showed that the most significant independent variable was age ( 71 y) with a HR of 2.85 (CI 1.31-6.19). Conclusions: 1- Patients who did not received RT, due to several reasons, had poorer evolution. 2-In patients who received adjuvant treatment, it was suggested that age is the first variable to consider, although patients older than 71 can benefit of RT (see table)

  7. Ventilation perfusion radionuclide imaging in cryptogenic fibrosing alveolitis

    International Nuclear Information System (INIS)

    Bourke, S.J.; Hawkins, T.; Keavey, P.M.; Gascoigne, A.D.; Corris, P.A.

    1993-01-01

    There is increasing interest in ventilation perfusion (V/Q) imaging in cryptogenic fibrosing alveolitis because of the data these scans provide on the dynamic V/Q relationships in such patients undergoing single lung transplantation. We analysed the V/Q scans of 45 consecutive patients with advanced cryptogenic fibrosing alveolitis being considered for single lung transplantation. Scans were classified according to the presence, severity and degree of matching of defects in ventilation and perfusion images and the results were compared with the data obtained from lung function tests. Ventilation images showed defects in 13 (29%) and ''washout delay'' in 15 (33%) patients; 10 (22%) patients had asymmetric distribution of ventilation with one lung receiving >60% of total ventilation. Perfusion images showed normal perfusion in 8 (18%), mild defects in 18 (40%) and major defects in 19 (42%) patients. The distribution of perfusion between lungs was significantly asymmetric in 20 (45%) patients. V/Q images were matched in 15 (33%), mildly mismatched in 15 (33%) and severely mismatched in 15 (33%) patients, but the degree of V/Q mismatch did not show a relationship to KCO, PaO 2 or A-aO 2 gradient. The appearances were atypical of pulmonary embolism in eight patients. (Author)

  8. Cerebral amyloid angiopathy-related inflammation: imaging findings and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Martucci, Matia [Vall d' Hebron University Hospital, Neuroradiology Unit, Radiology Department (IDI), Barcelona (Spain); Catholic University of Sacred Heart, ' ' A. Gemelli' ' University Hospital, Department of Radiological Sciences, Rome (Italy); Sarria, Silvana; Coscojuela, Pilar; Vert, Carla; Siurana, Sahyly; Auger, Cristina; Rovira, Alex [Vall d' Hebron University Hospital, Neuroradiology Unit, Radiology Department (IDI), Barcelona (Spain); Toledo, Manuel [Vall d' Hebron University Hospital, Epilepsy Unit, Neurology Department, Barcelona (Spain)

    2014-04-15

    We aim to investigate the clinical onset, computed tomography (CT) and magnetic resonance (MR) imaging findings, and follow-up of patients with cerebral amyloid angiopathy (CAA)-related inflammation, an uncommon but clinically striking presentation of CAA. We retrospectively reviewed the clinical manifestations, CT/MR imaging findings, and outcome of ten consecutive patients with CAA-related inflammation. In each patient, a brain CT study was performed at hospital admission, and brain MR imaging was carried out 2 to 4 days later. Clinical and radiologic follow-up findings were evaluated in all patients. The most common clinical onset was rapidly progressive cognitive decline, followed by focal neurological signs. Brain CT/MR showed unenhanced expansive subcortical lesions, corresponding to areas of vasogenic edema, associated with chronic lobar, cortical, or cortical-subcortical micro/macrohemorrhages. Clinical symptoms recovered in a few weeks under treatment in eight patients and spontaneously in the remaining two. MRI follow-up at 2 to 12 months after treatment showed resolution of the lesions. Three patients experienced symptomatic disease recurrence, with new lesions on CT/MR. In the absence of histological data, early recognition of the clinical symptoms and typical radiologic features of CAA-related inflammation is essential to enable timely establishment of proper treatment. (orig.)

  9. Cerebral amyloid angiopathy-related inflammation: imaging findings and clinical outcome

    International Nuclear Information System (INIS)

    Martucci, Matia; Sarria, Silvana; Coscojuela, Pilar; Vert, Carla; Siurana, Sahyly; Auger, Cristina; Rovira, Alex; Toledo, Manuel

    2014-01-01

    We aim to investigate the clinical onset, computed tomography (CT) and magnetic resonance (MR) imaging findings, and follow-up of patients with cerebral amyloid angiopathy (CAA)-related inflammation, an uncommon but clinically striking presentation of CAA. We retrospectively reviewed the clinical manifestations, CT/MR imaging findings, and outcome of ten consecutive patients with CAA-related inflammation. In each patient, a brain CT study was performed at hospital admission, and brain MR imaging was carried out 2 to 4 days later. Clinical and radiologic follow-up findings were evaluated in all patients. The most common clinical onset was rapidly progressive cognitive decline, followed by focal neurological signs. Brain CT/MR showed unenhanced expansive subcortical lesions, corresponding to areas of vasogenic edema, associated with chronic lobar, cortical, or cortical-subcortical micro/macrohemorrhages. Clinical symptoms recovered in a few weeks under treatment in eight patients and spontaneously in the remaining two. MRI follow-up at 2 to 12 months after treatment showed resolution of the lesions. Three patients experienced symptomatic disease recurrence, with new lesions on CT/MR. In the absence of histological data, early recognition of the clinical symptoms and typical radiologic features of CAA-related inflammation is essential to enable timely establishment of proper treatment. (orig.)

  10. Live cell imaging combined with high-energy single-ion microbeam

    Science.gov (United States)

    Guo, Na; Du, Guanghua; Liu, Wenjing; Guo, Jinlong; Wu, Ruqun; Chen, Hao; Wei, Junzhe

    2016-03-01

    DNA strand breaks can lead to cell carcinogenesis or cell death if not repaired rapidly and efficiently. An online live cell imaging system was established at the high energy microbeam facility at the Institute of Modern Physics to study early and fast cellular response to DNA damage after high linear energy transfer ion radiation. The HT1080 cells expressing XRCC1-RFP were irradiated with single high energy nickel ions, and time-lapse images of the irradiated cells were obtained online. The live cell imaging analysis shows that strand-break repair protein XRCC1 was recruited to the ion hit position within 20 s in the cells and formed bright foci in the cell nucleus. The fast recruitment of XRCC1 at the ion hits reached a maximum at about 200 s post-irradiation and then was followed by a slower release into the nucleoplasm. The measured dual-exponential kinetics of XRCC1 protein are consistent with the proposed consecutive reaction model, and the measurements obtained that the reaction rate constant of the XRCC1 recruitment to DNA strand break is 1.2 × 10-3 s-1 and the reaction rate constant of the XRCC1 release from the break-XRCC1 complex is 1.2 × 10-2 s-1.

  11. Complications of laparoscopic cholecystectomy: an analysis of 400 consecutive cases

    International Nuclear Information System (INIS)

    Afzal, M.; Butt, M.Q.

    2014-01-01

    To analyze the complications of first 400 laparoscopic cholecystectomies (LC) for patients with symptomatic gall stone disease at a tertiary care hospital. Study Design: Quasi-experimental study. Place and Duration of Study: PNS Shifa Karachi and CMH Lahore, Pakistan from Nov 2009 to Jan 2013. Patients and Methods: A prospective analysis of complications occurring in first 400 consecutive laparoscopic cholecystectomies by a single consultant/unit at a tertiary care hospital was made. Out of total 421 patients presenting with symptomatic gall stone disease in a single unit, 21 cases that underwent open cholecystectomy were excluded from the study. Laparoscopic cholecystectomies were performed using three port and four port technique and data including age, sex, diagnosis, number of trocar placements, conversion to open surgery and its reasons, operative time, post-operative hospital stay and complications was collected on personal computer and analyzed using Statistical package for social sciences (SPSS) version 13. Results: Total 400 patients were included in study with median age of 44 years. Female to male ratio was 5.3: 1. Depending upon the preoperative diagnosis and laparoscopic findings, patients had diagnosis of Chronic cholecystitis / biliary colic 68.25%, acute cholecystitis 23.75%, empyema gall bladder 7.25%, gallstone pancreatitis 0.5% and mucocele gallbladder 0.25%. Median operating time was 30min. Median hospital stay was 1 days (range 1 -20 days). Conversion rate was 1.25%. Postoperative complications included bleeding 0.5%, biliaryperitonitis due to cystic duct leak 0.25%, biloma 0.25%, sub hepaticabscess 0.25%, subcutaneous fat necrosis right flank at drain site 0.25%, umbilical trocarsite infection 2%, keloid at umbilical port site 0.25% and incisional hernia at umbilicus 0.25%. There was one hospital death due to myocardial infarction on 2nd post-operative day. Conclusion: Laparoscopic Cholecystectomy is associated with some serious complications

  12. Adapting Parcellation Schemes to Study Fetal Brain Connectivity in Serial Imaging Studies

    DEFF Research Database (Denmark)

    Cheng, Xi; Wilm, Jakob; Seshamani, Sharmishtaa

    2013-01-01

    A crucial step in studying brain connectivity is the definition of the Regions Of Interest (ROI's) which are considered as nodes of a network graph. These ROI's identified in structural imaging reflect consistent functional regions in the anatomies being compared. However in serial studies...... of the developing fetal brain such functional and associated structural markers are not consistently present over time. In this study we adapt two non-atlas based parcellation schemes to study the development of connectivity networks of a fetal monkey brain using Diffusion Weighted Imaging techniques. Results...... demonstrate that the fetal brain network exhibits small-world characteristics and a pattern of increased cluster coefficients and decreased global efficiency. These findings may provide a route to creating a new biomarker for healthy fetal brain development....

  13. Feasibility and limitation of constructive interference in steady-state (CISS) MR imaging in neonates with lumbosacral myeloschisis

    Energy Technology Data Exchange (ETDEWEB)

    Hashiguchi, Kimiaki; Morioka, Takato; Yoshida, Fumiaki; Miyagi, Yasushi; Nagata, Shinji; Sasaki, Tomio [Kyushu University, Department of Neurosurgery, Graduate School of Medical Sciences, Fukuoka (Japan); Mihara, Futoshi; Yoshiura, Takashi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2007-07-15

    The aim of this study was to evaluate three-dimensional Fourier transformation-constructive interference in steady-state (CISS) imaging as a preoperative anatomical evaluation of the relationship between the placode, spinal nerve roots, CSF space, and the myelomeningocele sac in neonates with lumbosacral myeloschisis. Five consecutive patients with lumbosacral myeloschisis were included in this study. Magnetic resonance (MR) CISS, conventional T1-weighted (T1-W) and T2-weighted (T2-W) images were acquired on the day of birth to compare the anatomical findings with each sequence. We also performed curvilinear reconstruction of the CISS images, which can be reconstructed along the curved spinal cord and neural placode. Neural placodes were demonstrated in two patients on T1-W images and in three patients on T2-W images. T2-W images revealed a small number of nerve roots in two patients, while no nerve roots were demonstrated on T1-W images. In contrast, CISS images clearly demonstrated neural placodes and spinal nerve roots in four patients. These findings were in accordance with intraoperative findings. Curvilinear CISS images demonstrated the neuroanatomy around the myeloschisis in one slice. The resulting images were degraded by a band artifact that obstructed fine anatomical analysis of the nerve roots in the ventral CSF space. The placode and nerve roots could not be visualized in one patient in whom the CSF space was narrow due to the collapse of the myelomeningocele sac. MR CISS imaging is superior to T1-W and T2-W imaging for demonstrating the neural placode and nerve roots, although problems remain in terms of artifacts. (orig.)

  14. Epilepsy Surgery Series: A Study of 502 Consecutive Patients from a Developing Country

    Science.gov (United States)

    Al-Otaibi, Faisal; Baz, Salah; Althubaiti, Ibrahim; Aldhalaan, Hisham; MacDonald, David; Abalkhail, Tareq; Fiol, Miguel E.; Alyamani, Suad; Chedrawi, Aziza; Leblanc, Frank; Parrent, Andrew; Maclean, Donald; Girvin, John

    2014-01-01

    Purpose. To review the postoperative seizure outcomes of patients that underwent surgery for epilepsy at King Faisal Specialist Hospital & Research Centre (KFSHRC). Methods. A descriptive retrospective study for 502 patients operated on for medically intractable epilepsy between 1998 and 2012. The surgical outcome was measured using the ILAE criteria. Results. The epilepsy surgery outcome for temporal lobe epilepsy surgery (ILAE classes 1, 2, and 3) at 12, 36, and 60 months is 79.6%, 74.2%, and 67%, respectively. The favorable 12- and 36-month outcomes for frontal lobe epilepsy surgery are 62% and 52%, respectively. For both parietal and occipital epilepsy lobe surgeries the 12- and 36-month outcomes are 67%. For multilobar epilepsy surgery, the 12- and 36-month outcomes are 65% and 50%, respectively. The 12- and 36-month outcomes for functional hemispherectomy epilepsy surgery are 64.2% and 63%, respectively. According to histopathology diagnosis, mesiotemporal sclerosis (MTS) and benign CNS tumors had the best favorable outcome after surgery at 1 year (77.27% and 84.3%, resp.,) and 3 years (76% and 75%, resp.,). The least favorable seizure-free outcome after 3 years occurred in cases with dual pathology (66.6%). Thirty-four epilepsy patients with normal magnetic resonance imaging (MRI) brain scans were surgically treated. The first- and third-year epilepsy surgery outcome of 17 temporal lobe surgeries were (53%) and (47%) seizure-free, respectively. The first- and third-year epilepsy surgery outcomes of 15 extratemporal epilepsy surgeries were (47%) and (33%) seizure-free. Conclusion. The best outcomes are achieved with temporal epilepsy surgery, mesial temporal sclerosis, and benign CNS tumor. The worst outcomes are from multilobar surgery, dual pathology, and normal MRI. PMID:24627805

  15. DIfferential Subsampling with Cartesian Ordering (DISCO): a high spatio-temporal resolution Dixon imaging sequence for multiphasic contrast enhanced abdominal imaging.

    Science.gov (United States)

    Saranathan, Manojkumar; Rettmann, Dan W; Hargreaves, Brian A; Clarke, Sharon E; Vasanawala, Shreyas S

    2012-06-01

    To develop and evaluate a multiphasic contrast-enhanced MRI method called DIfferential Sub-sampling with Cartesian Ordering (DISCO) for abdominal imaging. A three-dimensional, variable density pseudo-random k-space segmentation scheme was developed and combined with a Dixon-based fat-water separation algorithm to generate high temporal resolution images with robust fat suppression and without compromise in spatial resolution or coverage. With institutional review board approval and informed consent, 11 consecutive patients referred for abdominal MRI at 3 Tesla (T) were imaged with both DISCO and a routine clinical three-dimensional SPGR-Dixon (LAVA FLEX) sequence. All images were graded by two radiologists using quality of fat suppression, severity of artifacts, and overall image quality as scoring criteria. For assessment of arterial phase capture efficiency, the number of temporal phases with angiographic phase and hepatic arterial phase was recorded. There were no significant differences in quality of fat suppression, artifact severity or overall image quality between DISCO and LAVA FLEX images (P > 0.05, Wilcoxon signed rank test). The angiographic and arterial phases were captured in all 11 patients scanned using the DISCO acquisition (mean number of phases were two and three, respectively). DISCO effectively captures the fast dynamics of abdominal pathology such as hyperenhancing hepatic lesions with a high spatio-temporal resolution. Typically, 1.1 × 1.5 × 3 mm spatial resolution over 60 slices was achieved with a temporal resolution of 4-5 s. Copyright © 2012 Wiley Periodicals, Inc.

  16. Superiority of resection over enucleation for schwannomas of the cervical vagus nerve: A retrospective cohort study of 22 consecutive patients.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Minni, Antonio; Masci, Federica; Ciamberlano, Bernardo; Pasqua, Rocco; Calio, Francesco G; Vietri, Francesco

    2016-05-01

    Schwannoma of the cervical vagus nerve is rare. Treatment options include intracapsular enucleation and en bloc resection. The purpose of this study was to compare the outcomes of enucleation and resection in terms of postoperative mortality and morbidity, freedom from vocal cord palsy, freedom from local recurrence, quality-adjusted life-year (QALY) and vocal handicap index (VHI). Twentytwo consecutive patients were divided into two groups. Patients in group A (n = 9) underwent intracapsular enucleation, whereas patients in Group B (n = 13) underwent en bloc resection. Main endpoints of the study were postoperative mortality and morbidity, freedom from vocal cord palsy, freedom from local recurrence and quality of life. The quality of life after surgery was assessed according to the quality-adjusted life-year (QALY) EQ-5D-5L methodology, and calculation of the voice handicap index (VHI). Postoperative mortality was nil. Morbidity included 1 wound dehiscence in group A and 2 transitory dysphagias in group B. Freedom from vocal cord palsy was 22% in group A and zero in group B (p = 0.15). Operation-specific local recurrence rate was 33% (3/9 patients) in group A and nil in group B (0/23 patients) (p = 0.05). QALYs was 0.55 in group A and 0.54 in group B (p = 1.0). VHI was 23.77 in group A and 26.15 in group B (p = 1.00). Resection is superior to enucleation in terms of freedom from local recurrence. Functional results are comparable for both techniques. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  17. A high sensitivity 20Mfps CMOS image sensor with readout speed of 1Tpixel/sec for visualization of ultra-high speed phenomena

    Science.gov (United States)

    Kuroda, R.; Sugawa, S.

    2017-02-01

    Ultra-high speed (UHS) CMOS image sensors with on-chop analog memories placed on the periphery of pixel array for the visualization of UHS phenomena are overviewed in this paper. The developed UHS CMOS image sensors consist of 400H×256V pixels and 128 memories/pixel, and the readout speed of 1Tpixel/sec is obtained, leading to 10 Mfps full resolution video capturing with consecutive 128 frames, and 20 Mfps half resolution video capturing with consecutive 256 frames. The first development model has been employed in the high speed video camera and put in practical use in 2012. By the development of dedicated process technologies, photosensitivity improvement and power consumption reduction were simultaneously achieved, and the performance improved version has been utilized in the commercialized high-speed video camera since 2015 that offers 10 Mfps with ISO16,000 photosensitivity. Due to the improved photosensitivity, clear images can be captured and analyzed even under low light condition, such as under a microscope as well as capturing of UHS light emission phenomena.

  18. Prevalence of simple liver cysts and hemangiomas in cirrhotic and non-cirrhotic patients submitted to magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Breno Victor Tomaz Galvao

    2013-07-01

    Full Text Available Objective To determine the prevalence of liver cysts and hemangiomas in the general population and in cirrhotic patients. Materials and Methods Retrospective, observational, and cross-sectional study selecting consecutive magnetic resonance imaging studies performed in the period from February to July 2011. A total of 303 patients (187 women and 116 men with mean age of 53.3 years were included in the present study. Patients with previously known liver lesions were excluded. The images were consensually analyzed by two observers in the search for simple liver cysts and typical liver hemangiomas, according to universally accepted imaging criteria. Lesions prevalence, diameters and location were determined in both cirrhotic and non-cirrhotic individuals. Results The authors observed prevalence of 8.6% for hemangiomas and 14.5% for simple cysts. No statistically significant difference was observed in relation to prevalence of hemangiomas and cysts among cirrhotic and non-cirrhotic patients (p = 0.954; p = 0.472. Conclusion In the present study, the prevalence of cysts and hemangiomas was higher than the prevalence reported by autopsy series. No influence of cirrhosis was observed on the prevalence and appearance of such incidental lesions.

  19. TRANSURETHRAL RADIOFREQUENCY HEATING OR THERMOTHERAPY FOR BENIGN PROSTATIC HYPERTROPHY - A PROSPECTIVE TRIAL ON 65 CONSECUTIVE CASES

    NARCIS (Netherlands)

    MEIER, AHP; WEIL, EHJ; VANDOORN, ESCV; VERHAEGH, GTCM; JANKNEGT, RA

    1992-01-01

    65 consecutive cases with symptomatic benign prostate hypertrophy were treated with transurethral radiowave thermotherapy (TURF) using the Thermex-II at a temperature of 44.5-degrees-C. We report uroflowmetry and symptom scores after a follow-up of 6 months. The mean age was 63 years, the mean

  20. Assessing Gait Impairments Based on Auto-Encoded Patterns of Mahalanobis Distances from Consecutive Steps.

    Science.gov (United States)

    Muñoz-Organero, Mario; Davies, Richard; Mawson, Sue

    2017-01-01

    Insole pressure sensors capture the force distribution patterns during the stance phase while walking. By comparing patterns obtained from healthy individuals to patients suffering different medical conditions based on a given similarity measure, automatic impairment indexes can be computed in order to help in applications such as rehabilitation. This paper uses the data sensed from insole pressure sensors for a group of healthy controls to train an auto-encoder using patterns of stochastic distances in series of consecutive steps while walking at normal speeds. Two experiment groups are compared to the healthy control group: a group of patients suffering knee pain and a group of post-stroke survivors. The Mahalanobis distance is computed for every single step by each participant compared to the entire dataset sensed from healthy controls. The computed distances for consecutive steps are fed into the previously trained autoencoder and the average error is used to assess how close the walking segment is to the autogenerated model from healthy controls. The results show that automatic distortion indexes can be used to assess each participant as compared to normal patterns computed from healthy controls. The stochastic distances observed for the group of stroke survivors are bigger than those for the people with knee pain.